Kudchadkar, Sapna R; Beers, M Claire; Ascenzi, Judith A; Jastaniah, Ebaa; Punjabi, Naresh M
2016-09-01
The architectural design of the pediatric intensive care unit may play a major role in optimizing the environment to promote patients' sleep while improving stress levels and the work experience of critical care nurses. To examine changes in nurses' perceptions of the environment of a pediatric critical care unit for promotion of patients' sleep and the nurses' work experience after a transition from multipatient rooms to single-patient rooms. A cross-sectional survey of nurses was conducted before and after the move to a new hospital building in which all rooms in the pediatric critical care unit were single-patient rooms. Nurses reported that compared with multipatient rooms, single-patient private rooms were more conducive to patients sleeping well at night and promoted a more normal sleep-wake cycle (P < .001). Monitors/alarms and staff conversations were the biggest factors that adversely influenced the environment for sleep promotion in both settings. Nurses were less annoyed by noise in single-patient rooms (33%) than in multipatient rooms (79%; P < .001) and reported improved exposure to sunlight. Use of single-patient rooms rather than multipatient rooms improved nurses' perceptions of the pediatric intensive care unit environment for promoting patients' sleep and the nurses' own work experience. ©2016 American Association of Critical-Care Nurses.
The functional unit of Japanese word naming: evidence from masked priming.
Verdonschot, Rinus G; Kiyama, Sachiko; Tamaoka, Katsuo; Kinoshita, Sachiko; Heij, Wido La; Schiller, Niels O
2011-11-01
Theories of language production generally describe the segment as the basic unit in phonological encoding (e.g., Dell, 1988; Levelt, Roelofs, & Meyer, 1999). However, there is also evidence that such a unit might be language specific. Chen, Chen, and Dell (2002), for instance, found no effect of single segments when using a preparation paradigm. To shed more light on the functional unit of phonological encoding in Japanese, a language often described as being mora based, we report the results of 4 experiments using word reading tasks and masked priming. Experiment 1 demonstrated using Japanese kana script that primes, which overlapped in the whole mora with target words, sped up word reading latencies but not when just the onset overlapped. Experiments 2 and 3 investigated a possible role of script by using combinations of romaji (Romanized Japanese) and hiragana; again, facilitation effects were found only when the whole mora and not the onset segment overlapped. Experiment 4 distinguished mora priming from syllable priming and revealed that the mora priming effects obtained in the first 3 experiments are also obtained when a mora is part of a syllable. Again, no priming effect was found for single segments. Our findings suggest that the mora and not the segment (phoneme) is the basic functional phonological unit in Japanese language production planning.
Spatial adaptation of the cortical visual evoked potential of the cat.
Bonds, A B
1984-06-01
Adaptation that is spatially specific for the adapting pattern has been seen psychophysically in humans. This is indirect evidence for independent analyzers (putatively single units) that are specific for orientation and spatial frequency in the human visual system, but it is unclear how global adaptation characteristics may be related to single unit performance. Spatially specific adaptation was sought in the cat visual evoked potential (VEP), with a view towards relating this phenomenon with what we know of cat single units. Adaptation to sine-wave gratings results in a temporary loss of cat VEP amplitude, with induction and recovery similar to that seen in human psychophysical experiments. The amplitude loss was specific for both the spatial frequency and orientation of the adapting pattern. The bandwidth of adaptation was not unlike the average selectivity of a population of cat single units.
ERIC Educational Resources Information Center
Robinson, Katja
2016-01-01
The purpose of this phenomenological study was to explore the lifeworlds of low-income, single student mothers in two contrasting welfare regimes, the United States and Germany, to understand how their individual experiences as students and as mothers at the micro-level were shaped by policies regarding childcare and financial support at the…
Is the orthographic/phonological onset a single unit in reading aloud?
Mousikou, Petroula; Coltheart, Max; Saunders, Steven; Yen, Lisa
2010-02-01
Two main theories of visual word recognition have been developed regarding the way orthographic units in printed words map onto phonological units in spoken words. One theory suggests that a string of single letters or letter clusters corresponds to a string of phonemes (Coltheart, 1978; Venezky, 1970), while the other suggests that a string of single letters or letter clusters corresponds to coarser phonological units, for example, onsets and rimes (Treiman & Chafetz, 1987). These theoretical assumptions were critical for the development of coding schemes in prominent computational models of word recognition and reading aloud. In a reading-aloud study, we tested whether the human reading system represents the orthographic/phonological onset of printed words and nonwords as single units or as separate letters/phonemes. Our results, which favored a letter and not an onset-coding scheme, were successfully simulated by the dual-route cascaded (DRC) model (Coltheart, Rastle, Perry, Langdon, & Ziegler, 2001). A separate experiment was carried out to further adjudicate between 2 versions of the DRC model.
Domanico, R; Davis, D K; Coleman, F; Davis, B O
2010-01-01
Objective: With neonatal intensive care units (NICUs) evolving from multipatient wards toward family-friendly, single-family room units, the study objective was to compare satisfaction levels of families and health-care staff across these differing NICU facility designs. Study Design: This prospective study documented, by means of institutional review board-approved questionnaire survey protocols, the perceptions of parents and staff from two contrasting NICU environments. Result: Findings showed that demographic subgroups of parents and staff perceived the advantages and disadvantages of the two facility designs differently. Staff perceptions varied with previous experience, acclimation time and employment position, whereas parental perceptions revealed a naiveté bias through surveys of transitional parents with experience in both NICU facilities. Conclusion: Use of transitional parent surveys showed a subject naiveté bias inherent in perceptions of inexperienced parents. Grouping all survey participants demographically provided more informative interpretations of data, and revealed staff perceptions to vary with position, previous training and hospital experience. PMID:20072132
Solanki, Kohmal; Bhatti, Nabeel; Bridle, Christopher
2016-06-01
Despite constituting a minority of senior house officers (SHO) in oral and maxillofacial surgery (OMFS), the number of singly-qualified medical trainees is growing. We describe the experience of a singly qualified medical trainee in OMFS and the unique benefits and opportunities for potential trainees and the department. Overall, the advantages of synergistic training outweigh any deficiencies in knowledge, and in our experience, having both medical and dental trainees in our unit has maximised training opportunities and provided a more holistic approach to patient care. Increased exposure to conditions in the head and neck also benefits trainees who wish to pursue careers in other specialties such as ear, nose, and throat (ENT), neurosurgery, ophthalmology, and plastic surgery. Copyright © 2016 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
DOT National Transportation Integrated Search
1999-10-01
This analysis brief explores differences and similarities among the national crash experience of combination-unit trucks (CUTs), single-unit trucks (SUTs), and "all vehicles" (principally cars and light truck/vans). These CUT vs. SUT vs. all vehicle ...
Optimal maintenance policy incorporating system level and unit level for mechanical systems
NASA Astrophysics Data System (ADS)
Duan, Chaoqun; Deng, Chao; Wang, Bingran
2018-04-01
The study works on a multi-level maintenance policy combining system level and unit level under soft and hard failure modes. The system experiences system-level preventive maintenance (SLPM) when the conditional reliability of entire system exceeds SLPM threshold, and also undergoes a two-level maintenance for each single unit, which is initiated when a single unit exceeds its preventive maintenance (PM) threshold, and the other is performed simultaneously the moment when any unit is going for maintenance. The units experience both periodic inspections and aperiodic inspections provided by failures of hard-type units. To model the practical situations, two types of economic dependence have been taken into account, which are set-up cost dependence and maintenance expertise dependence due to the same technology and tool/equipment can be utilised. The optimisation problem is formulated and solved in a semi-Markov decision process framework. The objective is to find the optimal system-level threshold and unit-level thresholds by minimising the long-run expected average cost per unit time. A formula for the mean residual life is derived for the proposed multi-level maintenance policy. The method is illustrated by a real case study of feed subsystem from a boring machine, and a comparison with other policies demonstrates the effectiveness of our approach.
Jastreboff, P J; Tarnecki, R
1975-01-01
Experiments were done on the cats under Chloralose and/or Nembutal anesthesia. A click was used as a standard acoustic stimulus. The type of responses of single units from cerebellar vermis lobuli V-VII were analyzed. At least four different types of single unit reactions were observed and one of these - oscillatory - was produced by the presence of Flaxedil simultaneously with Chloralose. The system that controls the activity of the middle-ear-muscles can be suspected as the source of the oscillatory pattern of the cerebellar response. Latencies were found to be constant, independent of anesthesia, but it was necessary to have a low level of Nembutal anesthesia because of the overriding inhibitory influence of Nembutal.
McNulty, P A; Cresswell, A G
2004-06-01
We investigated the recruitment behaviour of low threshold motor units in flexor digitorum superficialis by altering two biomechanical constraints: the load against which the muscle worked and the initial muscle length. The load was increased using isotonic (low load), loaded dynamic (intermediate load) and isometric (high load) contractions in two studies. The initial muscle position reflected resting muscle length in series A, and a longer length with digit III fully extended in series B. Intramuscular EMG was recorded from 48 single motor units in 10 experiments on five healthy subjects, 21 units in series A and 27 in series B, while subjects performed ramp up, hold and ramp down contractions. Increasing the load on the muscle decreased the force, displacement and firing rate of single motor units at recruitment at shorter muscle lengths (P<0.001, dependent t-test). At longer muscle lengths this recruitment pattern was observed between loaded dynamic and isotonic contractions, but not between isometric and loaded dynamic contractions. Thus, the recruitment properties of single motor units in human flexor digitorum superficialis are sensitive to changes in both imposed external loads and the initial length of the muscle.
Project Physics Handbook 5, Models of the Atom.
ERIC Educational Resources Information Center
Harvard Univ., Cambridge, MA. Harvard Project Physics.
Five experiments and 19 activities are presented in this Unit 5 handbook. The experiments are related to electrolysis, charge-to-mass ratio, elementary charge determination, photoelectric effects, and spectroscopic analyses. The activities are concerned with Dalton's theory, water electrolysis, periodic tables, single-electron plating, cloud…
One pediatric burn unit's experience with sleepwear related injuries
McLoughlin, E.; Clarke, N.; Stahl, K.; Crawford, J.
1998-01-01
Review of the records of 678 children with acute injuries referred during an eight year period to this burn unit indicated that flame burns from a single ignition source (50%) outranked scalds (27%) or house fires (12%) as causes of injury. There was no temporal trend in the rank pattern. The majority of these single-source flame injuries were severe and involved ignition of the child's clothing. From 1969 through 1973, sleepwear was the clothing involved in 32% of the instances. Since that time and coincident with promulgation of strict federal and state standards for flammability of children's night clothing, a dramatic decline in the number of children referred with injuries of this type has taken place. It is probable that the single factor most important to the decline, in our experience with these injuries, is lower fabric flammability but, because our data may not be representative, corroboration is needed before one can exclude factors such as altered garment design, fire safety related practices at home, or changing patterns of hospital referral. PMID:9887427
Jastreboff, P J; Tarnecki, R
1975-01-01
Experiments were performed on cats under Chloralose or Nembutal anesthesia. The parameters of the acoustic click stimuli were found to have a strong influence on the responses registered from both the surface of the cerebellar vermis lobuli V up VII as well as from single units. It was shown that a stimulus frequency rate not greater than 1/2 s should be used, since higher frequencies caused strong attenuation of the response. The type of anesthesia did not change the latencies of reactions of both evoked potentials and single units. However, decreasing the strength of the click resulted in increased response latencies, in the case of single unit reactions. A very strong influence of weak visual stimuli on units was also observed. It is suggested that mossy fibers are the most important fibers in the transmission of acoustic information to the cerebellar cortex.
Cord Blood Banking and Transplantation in China: A Ten Years Experience of a Single Public Bank.
Liu, Jinhui; He, Ji; Chen, Shu; Qin, Fei; Wang, Fang; Xu, Gang; Zhu, Faming; Lv, Hangjun; Yan, Lixing
2012-02-01
BACKGROUND: Umbilical cord blood (UCB) has successfully used for transplantation to treat hematologic malignancies and genetic diseases. Herein, we describe the experience generated in a single public UCB bank at Zhejiang Province in China. METHODS: Good manufacturing practice and standard operating procedures were used to address donor selection as well as UCB collection, processing, and cryopreservation. Total nucleated cells (TNCs), cellular viability, CD34+ cells, and colony-forming units were determined, and infectious diseases screening test, sterility test, and HLA typing for UCB units were done. RESULTS: Only 18.51% of all collected UCB units met storage criteria, and 7,056 UCB units were cryopreserved in 10 years. The volume of UCB units was 95.0 ± 22.0 ml. The number of TNCs before and after processing was 13.32 ± 3.63 × 10(8) and 10.63 ± 2.80 × 10(8), respectively, and the recovery rate was 80.71 ± 11.26%. 0.4344 ± 0.1874% of the TNCs were CD34+ cells. The CFU-GM was 32.1 ± 28.0 colonies per 1 × 10(5) nucleated cells. Based mainly on HLA and nucleated cell content, 26 UCB units were released for transplantation. CONCLUSIONS: A public UCB bank was successfully established in China; collection and processing of UCB units should be optimized in order to gain maximum volume and cell count.
ERIC Educational Resources Information Center
Osborne, Jo; Dibben, Mark
2017-01-01
Universities are increasingly recognising the need to broaden the experience and understanding of their students beyond a single disciplinary approach, to produce graduates more capable of solving the problems of a multidisciplinary world. At the University of Tasmania, a "breadth unit" programme is underway with the dual purpose of…
ERIC Educational Resources Information Center
Kier, Scott A.
2012-01-01
Catholic identity is considered to be the single most important issue facing Catholic higher education in the United States. Scholars (Burtchaell, 1998; Gallin, 1999; Gleason, 1995; Heft, 2003; Marsden, 1994; O'Brien, 1994) have suggested that sustaining Catholic identity and preventing secularization depends on the integration of the…
ERIC Educational Resources Information Center
Yamaguchi, Motonori; Randle, James M.; Wilson, Thomas L.; Logan, Gordon D.
2017-01-01
Hierarchical control of skilled performance depends on chunking of several lower-level units into a single higher-level unit. The present study examined the relationship between chunking and recognition of trained materials in the context of typewriting. In 3 experiments, participants were trained with typing nonwords and were later tested on…
NASA Technical Reports Server (NTRS)
Macewen, J. D.; Vernot, E. H.
1971-01-01
The activities of the Toxic Hazards Research Unit (THRU) for the period of June 1970 through May 1971 reviewed. Modification of the animal exposure facilities primarily for improved human safety but also for experimental integrity and continuity are discussed. Acute toxicity experiments were conducted on hydrogen fluoride (HF), hydrogen chloride (HCl), nitrogen dioxide (NO2), and hydrogen cyanide (HCN) both singly and in combination with carbon dioxide (CO). Additional acute toxicity experiments were conducted on oxygen difluoride (OF2) and chlorine pentafluoride (ClF5). Subacute toxicity studies were conducted on methylisobutylketone and dichloromethane (methylene dichloride). The interim results of further chronic toxicity experiments on monomethylhydrazine (MMH) are also described.
Kim, Hyun Sook; Yeom, Hye-Ah
2018-06-01
To describe the spiritual well-being and burnout of intensive care unit nurses and examine the relationship between these factors. This was a cross-sectional descriptive study. The participants were 318 intensive care unit recruited from three university hospitals in South Korea. The survey questionnaire included demographic information, work-related characteristics and end-of-life care experience, along with the Spiritual Well-Being Scale and Burnout Questionnaire. The data were analysed using descriptive statistics, t-tests, ANOVA with Scheffé test and a multiple regression analysis. The burnout level among intensive care unit nurses was 3.15 out of 5. A higher level of burnout was significantly associated with younger age, lower education level, single marital status, having no religion, less work experience and previous end-of-life care experience. Higher levels of spiritual well-being were associated with lower levels of burnout, even after controlling for the general characteristics in the regression model. Intensive care unit nurses experience a high level of burnout in general. Increased spiritual well-being might reduce burnout among intensive care unit nurses. Younger and less experienced nurses should receive more attention as a vulnerable group with lower spirituality and greater burnout in intensive care unit settings. Copyright © 2017 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Spyrou, Spyros
2013-01-01
This article presents some of the key findings from a comparative, qualitative research study carried out in the United Kingdom, Greece, and Cyprus. The main goal of the study was to investigate single-parent children's experiences and understandings of poverty and social exclusion in their everyday lives and to make relevant policy…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Staller, G.E.; Hamilton, I.D.; Aker, M.F.
1978-02-01
A single-unit electron beam accelerator was designed, fabricated, and assembled in Sandia's Technical Area V to conduct magnetically insulated transmission experiments. Results of these experiments will be utilized in the future design of larger, more complex accelerators. This design makes optimum use of existing facilities and equipment. When designing new components, possible future applications were considered as well as compatibility with existing facilities and hardware.
Single-port robotic cholecystectomy. Initial and pioneer experience in Brazil
Schraibman, Vladimir; Epstein, Marina Gabrielle; Maccapani, Gabriel Naman; Macedo, Antônio Luiz de Vasconcellos
2015-01-01
The technique of a single-port laparoscopy was developed over the last years as an attempt to lower surgical aggression and improve the aesthetic results of the minimally invasive surgery. A new robotic platform used with the da Vinci® Robotic System Single-Site System® (Intuitive Surgical, Sunnyvale, California, United States) was recently launched on the global market and is still not documented in Brazil. The authors report on the first four robotic single-port cholecystectomies performed with this da Vinci® Robotic System in Brazil. PMID:26398360
Karamanidis, Kiros; Arampatzis, Adamantios
2007-01-01
The goals of this study were to investigate whether the lower muscle-tendon units (MTUs) capacities in older affect their ability to recover balance with a single-step after a fall, and to examine whether running experience enhances and protects this motor skill in young and old adults. The investigation was conducted on 30 older and 19 younger divided into two subgroups: runners versus non-active. In previous studies we documented that the older had lower leg extensor muscle strength and tendon stiffness while running had no effect on MTUs capacities. The current study examined recovery mechanics of the same individuals after an induced forward fall. Younger were better able to recover balance with a single-step compared to older (P < 0.001); this ability was associated with a more effective body configuration at touchdown (more posterior COM position relative to the recovery foot, P <0.001). MTUs capacities classified 88.6% of the subjects into single- or multiple-steppers. Runners showed a superior ability to recover balance with a single-step (P < 0.001) compared to non-active subjects due to a more effective mechanical response during the stance phase (greater knee joint flexion, P <0.05). We concluded that the age-related degeneration of the MTUs significantly diminished the older adults' ability to restore balance with a single-step. Running seems to enhance and protect this motor skill. We suggested that runners, due to their running experience, could update the internal representation of mechanisms responsible for the control of dynamic stability during a forward fall and, thus, were able to restore balance more often with a single-step compared to the non-active subjects.
Results of the Thailand Warm-Cloud Hygroscopic Particle Seeding Experiment.
NASA Astrophysics Data System (ADS)
Silverman, Bernard A.; Sukarnjanaset, Wathana
2000-07-01
A randomized, warm-rain enhancement experiment was carried out during 1995-98 in the Bhumibol catchment area in northwestern Thailand. The experiment was conducted in accordance with a randomized, floating single-target design. The seeding targets were semi-isolated, warm convective clouds, contained within a well-defined experimental unit, that, upon qualification, were selected for seeding or not seeding with calcium chloride particles in a random manner. The seeding was done by dispensing the calcium chloride particles at an average rate of 21 kg km1 per seeding pass into the updrafts of growing warm convective clouds (about 1-2 km above cloud base) that have not yet developed or, at most, have just started to develop a precipitation radar echo. The experiment was carried out by the Bureau of Royal Rainmaking and Agricultural Aviation (BRRAA) of the Ministry of Agriculture and Cooperatives as part of its Applied Atmospheric Resources Research Program, Phase 2.During the 4 yr of the experiment, a total of 67 experimental units (34 seeded and 33 nonseeded units) were qualified in accordance with the experimental design. Volume-scan data from a 10-cm Doppler radar at 5-min intervals were used to track each experimental unit, from which various radar-estimated properties of the experimental units were obtained. The statistical evaluation of the experiment was based on a rerandomization analysis of the single ratio of seeded to unseeded experimental unit lifetime properties. In 1997, the BRRAA acquired two sophisticated King Air 350 cloud-physics aircraft, providing the opportunity to obtain physical measurements of the aerosol characteristics of the environment in which the warm clouds grow, of the hydrometeor characteristics of seeded and unseeded clouds, and of the calcium chloride seeding plume dimensions and particle size distribution-information directly related to the effectiveness of the seeding conceptual model that was not directly available up to then.The evaluation of the Thailand warm-rain enhancement experiment has provided statistically significant evidence and supporting physical evidence that the seeding of warm convective clouds with calcium chloride particles produced more rain than was produced by their unseeded counterparts. An exploratory analysis of the time evolution of the seeding effects resulted in a significant revision to the seeding conceptual model.
Dapia, Irene; Tong, Hoi Y.; Arias, Pedro; Muñoz, Mario; Tenorio, Jair; Hernández, Rafael; García García, Irene; Gordo, Gema; Ramírez, Elena; Frías, Jesús; Lapunzina, Pablo; Carcas, Antonio J.
2017-01-01
Abstract In 2014, we established a pharmacogenetics unit with the intention of facilitating the integration of pharmacogenetic testing into clinical practice. This unit was centered around two main ideas: i) individualization of clinical recommendations, and ii) preemptive genotyping in risk populations. Our unit is based on the design and validation of a single nucleotide polymorphism (SNP) microarray, which has allowed testing of 180 SNPs associated with drug response (PharmArray), and clinical consultation regarding the results. Herein, we report our experience in integrating pharmacogenetic testing into our hospital and we present the results of the 2,539 pharmacogenetic consultation requests received over the past 3 years in our unit. The results demonstrate the feasibility of implementing pharmacogenetic testing in clinical practice within a national health system. PMID:29193749
United States experience using forward scattermeters for runway visual range
DOT National Transportation Integrated Search
1997-03-01
The forward scattermeter has many practical advantages over the transmissometer (single mounting pole, greater dynamic range, etc.). However, before a forward scattermeter could be accepted for an RVR system, a number of criteria had to be satisfied:...
Ramirez-Arcos, Sandra; Mastronardi, Cherie; Perkins, Heather; Kou, Yuntong; Turner, Tracey; Mastronardi, Emily; Hansen, Adele; Yi, Qi-Long; McLaughlin, Natasha; Kahwash, Eiad; Lin, Yulia; Acker, Jason
2013-04-01
A 30-minute rule was established to limit red blood cell (RBC) exposure to uncontrolled temperatures during storage and transportation. Also, RBC units issued for transfusion should not remain at room temperature (RT) for more than 4 hours (4-hour rule). This study was aimed at determining if single or multiple RT exposures affect RBC quality and/or promote bacterial growth. Growth and RT exposure experiments were performed in RBCs inoculated with Serratia liquefaciens and Serratia marcescens. RBCs were exposed once to RT for 5 hours (S. liquefaciens) or five times to RT for 30 minutes (S. marcescens) with periodic sampling for bacterial counts. Noncontaminated units were exposed to RT once (5 hr) or five times (30 min each) and sampled to measure in vitro quality variables. RBC core temperature was monitored using mock units with temperature loggers. Growth and RT exposure experiments were repeated three and at least six times, respectively. Statistical analysis was done using mixed-model analysis. RBC core temperature ranged from 7.3 to 11.6°C during 30-minute RT exposures and the time to reach 10°C varied from 22 to 55 minutes during 5-hour RT exposures. RBC quality was preserved after single or multiple RT exposures. Increased growth of S. liquefaciens was only observed after 2 hours of continuous RT exposure. S. marcescens concentration increased significantly in multiple-exposed units compared to the controls but did not reach clinically important levels. Single or multiple RT exposures did not affect RBC quality but slightly promoted bacterial growth in contaminated units. The clinical significance of these results remains unclear and needs further investigation. © 2012 American Association of Blood Banks.
ERIC Educational Resources Information Center
Wilson, Angie D.; Henriksen, Richard C.; Bustamante, Rebecca; Irby, Beverly
2016-01-01
The phenomenon of absent fathers is a common occurrence in today's homes that appears to be escalating, especially in Black households across the United States. The purpose of this study was to describe the lived experiences of successful Black men who were raised in absent-father homes as well as the lived experiences of their resilient single…
A review of the quantum current standard
NASA Astrophysics Data System (ADS)
Kaneko, Nobu-Hisa; Nakamura, Shuji; Okazaki, Yuma
2016-03-01
The electric current, voltage, and resistance standards are the most important standards related to electricity and magnetism. Of these three standards, only the ampere, which is the unit of electric current, is an International System of Units (SI) base unit. However, even with modern technology, relatively large uncertainty exists regarding the generation and measurement of current. As a result of various innovative techniques based on nanotechnology and novel materials, new types of junctions for quantum current generation and single-electron current sources have recently been proposed. These newly developed methods are also being used to investigate the consistency of the three quantum electrical effects, i.e. the Josephson, quantum Hall, and single-electron tunneling effects, which are also known as ‘the quantum metrology triangle’. This article describes recent research and related developments regarding current standards and quantum-metrology-triangle experiments.
Electromyographic cross-talk within a compartmentalized muscle of the cat.
English, A W; Weeks, O I
1989-01-01
1. Experiments were conducted to test the extent to which the electromyographic (EMG) activity generated by the activation of single motor units is conducted from one neuromuscular compartment of the cat lateral gastrocnemius (LG) muscle into adjacent compartments. 2. Potentials produced by stimulation of forty-five single motor units were monitored from bipolar fine-wire EMG electrodes which had been implanted either into the centres of each of the four neuromuscular compartments of LG or into regions of the muscle known to lie on the border of contiguous compartments. 3. In all cases single unit potentials could be recorded from the electrodes in the centre of the compartments which clearly identified the compartment of residence of the muscle unit. Regardless of unit type, the amplitude of the potential recorded from electrodes in one compartment was always greater than that recorded from any other compartment. 4. Smaller potentials could be recorded from electrodes in the centre of compartments adjacent to the compartment of residence of the muscle unit. For those motor units where the amplitude of the EMG potentials recorded from the compartment of residence was large, the amplitude of such 'cross-talk' could be greater than the amplitude of potentials recorded from the compartment of residence of smaller motor units. 5. In the case of electrodes placed at compartment boundaries, no clear compartment selectivity of recording of motor unit potentials was evident. 6. These results indicate that great care must be taken in choosing sites of EMG electrode placement when performing kinesiological studies, especially when the amplitude of the EMG activity recorded is of consideration. PMID:2558175
NASA Technical Reports Server (NTRS)
Woodroffe, J. M.; Davies, P. G.; Ladd, D. N.; Norbury, John R.
1994-01-01
This paper describes the current experimental program and future plans for the reception of transmissions from the 18.7, 39.6, and 49.5 GHz beacons from the ITALSAT satellite by the Radio Communications Research Unit at Rutherford Appleton Laboratory, UK. The Radio Communications Research Unit, which has had considerable experience in developing experimental millimetric equipment for propagation studies, has initiated the development of a single-channel receiver and a triple-channel receiver to measure propagation effects at 49.5 GHz and 39.6 GHz respectively. The initial location of the receivers will be at Chilbolton, Hampshire, UK.
Industrial application experiment series
NASA Technical Reports Server (NTRS)
Bluhm, S. A.
1981-01-01
Two procurements within the Industrial Application Experiment Series of the Thermal Power Systems Project are discussed. The first procurement, initiated in April 1980, resulted in an award to the Applied Concepts Corporation for the Capital Concrete Experiment: two Fresnel concentrating collectors will be evaluated in single-unit installations at the Jet Propulsion Laboratory Parabolic Dish Test Site and at Capitol Concrete Products, Topeka, Kansas. The second procurement, initiated in March 1981, is titled, "Thermal System Engineering Experiment B." The objective of the procurement is the rapid deployment of developed parabolic dish collectors.
NASA Astrophysics Data System (ADS)
Bodappa, Nataraju; Fluch, Ulrike; Fu, Yongchun; Mayor, Marcel; Moreno-García, Pavel; Siegenthaler, Hans; Wandlowski, Thomas
2014-11-01
Single gold particles may serve as room temperature single electron memory units because of their size dependent electronic level spacing. Here, we present a proof-of-concept study by electrochemically controlled scanning probe experiments performed on tailor-made Au particles of narrow dispersity. In particular, the charge transport characteristics through chemically synthesized hexane-1-thiol and 4-pyridylbenzene-1-thiol mixed monolayer protected Au144 clusters (MPCs) by differential pulse voltammetry (DPV) and electrochemical scanning tunneling spectroscopy (EC-STS) are reported. The pyridyl groups exposed by the Au-MPCs enable their immobilization on Pt(111) substrates. By varying the humidity during their deposition, samples coated by stacks of compact monolayers of Au-MPCs or decorated with individual, laterally separated Au-MPCs are obtained. DPV experiments with stacked monolayers of Au144-MPCs and EC-STS experiments with laterally separated individual Au144-MPCs are performed both in aqueous and ionic liquid electrolytes. Lower capacitance values were observed for individual clusters compared to ensemble clusters. This trend remains the same irrespective of the composition of the electrolyte surrounding the Au144-MPC. However, the resolution of the energy level spacing of the single clusters is strongly affected by the proximity of neighboring particles.Single gold particles may serve as room temperature single electron memory units because of their size dependent electronic level spacing. Here, we present a proof-of-concept study by electrochemically controlled scanning probe experiments performed on tailor-made Au particles of narrow dispersity. In particular, the charge transport characteristics through chemically synthesized hexane-1-thiol and 4-pyridylbenzene-1-thiol mixed monolayer protected Au144 clusters (MPCs) by differential pulse voltammetry (DPV) and electrochemical scanning tunneling spectroscopy (EC-STS) are reported. The pyridyl groups exposed by the Au-MPCs enable their immobilization on Pt(111) substrates. By varying the humidity during their deposition, samples coated by stacks of compact monolayers of Au-MPCs or decorated with individual, laterally separated Au-MPCs are obtained. DPV experiments with stacked monolayers of Au144-MPCs and EC-STS experiments with laterally separated individual Au144-MPCs are performed both in aqueous and ionic liquid electrolytes. Lower capacitance values were observed for individual clusters compared to ensemble clusters. This trend remains the same irrespective of the composition of the electrolyte surrounding the Au144-MPC. However, the resolution of the energy level spacing of the single clusters is strongly affected by the proximity of neighboring particles. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr03793f
Thermal integration of Spacelab experiments
NASA Technical Reports Server (NTRS)
Patterson, W. C.; Hopson, G. D.
1978-01-01
The method of thermally integrating the experiments for Spacelab is discussed. The scientific payload consists of a combination of European and United States sponsored experiments located in the module as well as on a single Spacelab pallet. The thermal integration must result in accomodating the individual experiment requirements as well as ensuring that the total payload is within the Spacelab Environmental Control System (ECS) resource capability. An integrated thermal/ECS analysis of the module and pallet is performed in concert with the mission timeline to ensure that the agreed upon experiment requirements are accommodated and to ensure the total payload is within the Spacelab ECS resources.
Testing a model of componential processing of multi-symbol numbers-evidence from measurement units.
Huber, Stefan; Bahnmueller, Julia; Klein, Elise; Moeller, Korbinian
2015-10-01
Research on numerical cognition has addressed the processing of nonsymbolic quantities and symbolic digits extensively. However, magnitude processing of measurement units is still a neglected topic in numerical cognition research. Hence, we investigated the processing of measurement units to evaluate whether typical effects of multi-digit number processing such as the compatibility effect, the string length congruity effect, and the distance effect are also present for measurement units. In three experiments, participants had to single out the larger one of two physical quantities (e.g., lengths). In Experiment 1, the compatibility of number and measurement unit (compatible: 3 mm_6 cm with 3 < 6 and mm < cm; incompatible: 3 cm_6 mm with 3 < 6 but cm > mm) as well as string length congruity (congruent: 1 m_2 km with m < km and 2 < 3 characters; incongruent: 2 mm_1 m with mm < m, but 3 > 2 characters) were manipulated. We observed reliable compatibility effects with prolonged reaction times (RT) for incompatible trials. Moreover, a string length congruity effect was present in RT with longer RT for incongruent trials. Experiments 2 and 3 served as control experiments showing that compatibility effects persist when controlling for holistic distance and that a distance effect for measurement units exists. Our findings indicate that numbers and measurement units are processed in a componential manner and thus highlight that processing characteristics of multi-digit numbers generalize to measurement units. Thereby, our data lend further support to the recently proposed generalized model of componential multi-symbol number processing.
Associative memory in aging: the effect of unitization on source memory.
Bastin, Christine; Diana, Rachel A; Simon, Jessica; Collette, Fabienne; Yonelinas, Andrew P; Salmon, Eric
2013-03-01
In normal aging, memory for associations declines more than memory for individual items. Unitization is an encoding process defined by creation of a new single entity to represent a new arbitrary association. The current study tested the hypothesis that age-related differences in associative memory can be reduced by encoding instructions that promote unitization. In two experiments, groups of 20 young and 20 older participants learned new associations between a word and a background color under two conditions. In the item detail condition, they had to imagine that the item is the same color as the background-an instruction promoting unitization of the associations. In the context detail condition, which did not promote unitization, they had to imagine that the item interacted with another colored object. At test, they had to retrieve the color that was associated with each word (source memory). In both experiments, the results showed an age-related decrement in source memory performance in the context detail but not in the item detail condition. Moreover, Experiment 2 examined receiver operating characteristics in older participants and indicated that familiarity contributed more to source memory performance in the item detail than in the context detail condition. These findings suggest that unitization of new associations can overcome the associative memory deficit observed in aging, at least for item-color associations.
ERIC Educational Resources Information Center
Rowling, Louise
In two parts, this paper discusses areas in family disruption, describes children's experiences of loss, and suggests strategies for helping children cope with such experiences. Specifically, part one provides: (1) global, normative summary descriptions of adjustment patterns of children from preschool age through adolescence and descriptions of…
Geyman, John P
2005-01-01
Recent years have seen the rapid growth of private think tanks within the neoconservative movement that conduct "policy research" biased to their own agenda. This article provides an evidence-based rebuttal to a 2002 report by one such think tank, the Dallas-based National Center for Policy Analysis (NCPA), which was intended to discredit 20 alleged myths about single-payer national health insurance as a policy option for the United States. Eleven "myths" are rebutted under eight categories: access, cost containment, quality, efficiency, single-payer as solution, control of drug prices, ability to compete abroad (the "business case"), and public support for a single-payer system. Six memes (self-replicating ideas that are promulgated without regard to their merits) are identified in the NCPA report. Myths and memes should have no place in the national debate now underway over the future of a failing health care system, and need to be recognized as such and countered by experience and unbiased evidence.
White, Mark J; Thornton, John S; Hawkes, David J; Hill, Derek L G; Kitchen, Neil; Mancini, Laura; McEvoy, Andrew W; Razavi, Reza; Wilson, Sally; Yousry, Tarek; Keevil, Stephen F
2015-01-01
The design and operation of a facility in which a magnetic resonance imaging (MRI) scanner is incorporated into a room used for surgical or endovascular cardiac interventions presents several challenges. MR safety must be maintained in the presence of a much wider variety of equipment than is found in a diagnostic unit, and of staff unfamiliar with the MRI environment, without compromising the safety and practicality of the interventional procedure. Both the MR-guided cardiac interventional unit at Kings College London and the intraoperative imaging suite at the National Hospital for Neurology and Neurosurgery are single-room interventional facilities incorporating 1.5 T cylindrical-bore MRI scanners. The two units employ similar strategies to maintain MR safety, both in original design and day-to-day operational workflows, and between them over a decade of incident-free practice has been accumulated. This article outlines these strategies, highlighting both similarities and differences between the units, as well as some lessons learned and resulting procedural changes made in both units since installation. © 2014 Wiley Periodicals, Inc.
Phelps, Carey; Israels, Brett; Marsh, Morgan C; von Hippel, Peter H; Marcus, Andrew H
2016-12-29
Recent advances in single-molecule fluorescence imaging have made it possible to perform measurements on microsecond time scales. Such experiments have the potential to reveal detailed information about the conformational changes in biological macromolecules, including the reaction pathways and dynamics of the rearrangements involved in processes, such as sequence-specific DNA "breathing" and the assembly of protein-nucleic acid complexes. Because microsecond-resolved single-molecule trajectories often involve "sparse" data, that is, they contain relatively few data points per unit time, they cannot be easily analyzed using the standard protocols that were developed for single-molecule experiments carried out with tens-of-millisecond time resolution and high "data density." Here, we describe a generalized approach, based on time-correlation functions, to obtain kinetic information from microsecond-resolved single-molecule fluorescence measurements. This approach can be used to identify short-lived intermediates that lie on reaction pathways connecting relatively long-lived reactant and product states. As a concrete illustration of the potential of this methodology for analyzing specific macromolecular systems, we accompany the theoretical presentation with the description of a specific biologically relevant example drawn from studies of reaction mechanisms of the assembly of the single-stranded DNA binding protein of the T4 bacteriophage replication complex onto a model DNA replication fork.
2 x 2 Polyethylene Reflected and Moderated Highly Enriched Uranium System with Rhenium
DOE Office of Scientific and Technical Information (OSTI.GOV)
A. Nichole Ellis; Jesson Hutchinson; John D. Bess
2010-09-01
The 2 × 2 array HEU-Re experiment was performed on the Planet universal critical assembly machine on November 4th, 2003 at the Los Alamos Critical Experiments Facility (LACEF) at Los Alamos National Laboratory (LANL). For this experiment, there were 10 ½ units, each full unit containing four HEU foils and two rhenium foils. The top unit contained only two HEU foils and two rhenium foils. A total of 42 HEU foils were used for this experiment. Rhenium is a desirable cladding material for space nuclear power applications. This experiment consisted of HEU foils interleaved with rhenium foils and is moderatedmore » and reflected by polyethylene plates. A unit consisted of a polyethylene plate, which has a recess for rhenium foils, and four HEU foils in a single layer in the top recess of each polyethylene plate. The Planet universal criticality assembly machine has been previously used in experiments containing HEU foils interspersed with SiO2 (HEU-MET-THERM-001), Al (HEU-MET-THERM-008), MgO (HEU-MET-THERM-009), Gd foils (HEU-MET-THERM-010), 2 × 2 × 26 Al (HEU-MET-THERM-012), Fe (HEU-MET-THERM-013 and HEU-MET-THERM-015), 2 × 2 × 23 SiO2 (HEU-MET-THERM-014), 2 × 2 × 11 hastalloy plates (HEU-MET-THERM-016), and concrete (HEU-MET-THERM-018). The 2 × 2 array of HEU-Re is considered acceptable for use as a benchmark critical experiment.« less
Rahe-Meyer, Niels; Pawlak, Matthias; Weilbach, Christian; Osthaus, Wilhelm Alexander; Ruhschulte, Hainer; Solomon, Cristina; Piepenbrock, Siegfried; Winterhalter, Michael
2008-01-01
Background The devices used for in vivo examination of muscle contractions assess only pure force contractions and the so-called isokinetic contractions. In isokinetic experiments, the extremity and its muscle are artificially moved with constant velocity by the measuring device, while a tetanic contraction is induced in the muscle, either by electrical stimulation or by maximal voluntary activation. With these systems, experiments cannot be performed at pre-defined, constant muscle length, single contractions cannot be evaluated individually and the separate examination of the isometric and the isotonic components of single contractions is not possible. Methods The myograph presented in our study has two newly developed technical units, i.e. a). a counterforce unit which can load the muscle with an adjustable, but constant force and b). a length-adjusting unit which allows for both the stretching and the contraction length to be infinitely adjustable independently of one another. The two units support the examination of complex types of contraction and store the counterforce and length-adjusting settings, so that these conditions may be accurately reapplied in later sessions. Results The measurement examples presented show that the muscle can be brought to every possible pre-stretching length and that single isotonic or complex isometric-isotonic contractions may be performed at every length. The applied forces act during different phases of contraction, resulting into different pre- and after-loads that can be kept constant – uninfluenced by the contraction. Maximal values for force, shortening, velocity and work may be obtained for individual muscles. This offers the possibility to obtain information on the muscle status and to monitor its changes under non-invasive measurement conditions. Conclusion With the Complex Myograph, the whole spectrum of a muscle's mechanical characteristics may be assessed. PMID:18616815
United States Marine Corps Motor Transport Mechanic-to-Equipment Ratio
time motor transport equipment remains in maintenance at the organizational command level. This thesis uses a discrete event simulation model of the...applied to a single experiment that allows for assessment of risk of not achieving the objective. Inter-arrival time, processing time, work schedule
Cook, Kay
2012-09-01
Following the United States' lead, the emergence of neoliberal welfare policy across the western world has resulted in employment programmes for single parents, who are predominantly single mothers. While some governments claim that employment will improve single parents' incomes and well-being, researchers dispute that single parents can unproblematically move into the workforce, with net positive effects. While researchers have quantified the socio-economic effect of these programmes, in particular on participant health, no study has yet synthesized participants' experiences of welfare-to-work. Here, I present a meta-synthesis of eight qualitative health-related studies of single parents' (and exclusively single mothers') welfare-to-work transition. I report that single mothers faced a combination of health and economic issues which made their transition from welfare to work difficult, including degrees of poor physical and mental health. For participants in the United States, these health issues were often compounded by a loss of health benefits on moving into low-wage employment. In countries where a return to employment was required before children reached school age, a lack of affordable and appropriate child care, especially for children with health problems, exacerbated these difficulties. As a result of scarce resources, single mothers in receipt of welfare benefits often relied on food banks or went without food. A return to the workforce did not alleviate this problem as additional child care and reduced government subsidies depleted the funds available for food. I conclude that welfare-to-work policies are underpinned by the neoliberal assumption that the market more efficiently distributes resources than the State. However, for the women in the studies examined here, labour market participation often depleted access to essential resources. Interventions to address the 'problem' of welfare dependency must recognize the complex interplay between work incentives and disincentives and the care-work of single mothers.
reaxFF Reactive Force Field for Disulfide Mechanochemistry, Fitted to Multireference ab Initio Data.
Müller, Julian; Hartke, Bernd
2016-08-09
Mechanochemistry, in particular in the form of single-molecule atomic force microscopy experiments, is difficult to model theoretically, for two reasons: Covalent bond breaking is not captured accurately by single-determinant, single-reference quantum chemistry methods, and experimental times of milliseconds or longer are hard to simulate with any approach. Reactive force fields have the potential to alleviate both problems, as demonstrated in this work: Using nondeterministic global parameter optimization by evolutionary algorithms, we have fitted a reaxFF force field to high-level multireference ab initio data for disulfides. The resulting force field can be used to reliably model large, multifunctional mechanochemistry units with disulfide bonds as designed breaking points. Explorative calculations show that a significant part of the time scale gap between AFM experiments and dynamical simulations can be bridged with this approach.
Teaching Science with Garbage.
ERIC Educational Resources Information Center
Schatz, Albert; Schatz, Vivian
This single-concept unit on garbage is a "do-it-yourself" approach to environmental education. The emphasis is on composting or microbial decomposition under controlled conditions since composting appears to be one practical way of handling garbage. More than 30 simple experiments show some of the changes that garbage undergoes. The garbage…
NASA Astrophysics Data System (ADS)
Uunk, Bertram; Wijbrans, Jan; Brouwer, Fraukje
2017-04-01
White mica 40Ar/39Ar dating is a proven powerful tool for constraining the timing and rate of metamorphism, deformation and exhumation. However, for high-pressure metamorphic rocks dating often results in wide age ranges, which are not in agreement with constraints from other isotopic systems, indicating that geological and chemical processes complicate straightforward 40Ar/39Ar dating. Despite hosting one of the largest geochronological datasets in the world, the Cycladic Blueschist Unit in Greece is presently one of the focal areas in the discussion on the interpretation of metamorphic 40Ar/39Ar ages. Previous phengite multi grain step heating experiments commonly yielded undulating age spectra ranging between 20 - 60 Ma. While some studies attempt to assign geological significance to these ages, others argue the ages are geologically meaningless and the result of the interplay between partial diffusive resetting and continued crystallization. By taking an alternative approach of multiple single grain fusion experiments, this study investigates age heterogeneity between samples of contrasting metamorphic facies, rheology and strain from the Cycladic islands of Syros and Sifnos. Comparing the size and shape of single grain fusion age distributions at the grain, rock, outcrop and island scale allows determination of the scale at which different age-forming processes operate. Resulting ages show a previously unreported consistent variation between different outcrops, moving from the eclogite-blueschist facies (55-45 Ma) to greenschist overprinting (40-30 Ma). This indicates that outcrop scale homogeneous resetting is the dominant processes for age formation in the CBU. Single grain age variation at the sample and outcrop scale is only limited to 10 Ma, indicating a smaller but observable role for local age perturbing processes of incomplete resetting, continued (re)crystallization or infiltration of excess argon. Some of the partially overprinted samples show homogeneous single grain age populations, indicating at least a partial role for efficient resetting by thermally activated diffusion at the outcrop scale. Traditional multi grain step heating experiments on the same samples yield flat plateaus for various single grain age distributions, indicating that age heterogeneities resolved by single grain fusion dating are mixed to a meaningless average in step heating experiments. In contrast, our approach leads to a better understanding of the processes responsible for age formation during high pressure metamorphism.
Ocean Bottom Seismometer Augmentation of the Philippine Sea Experiment (OBSAPS) Cruise Report
2011-09-01
single 77.5Hz M-sequence on six OBSAPS receivers: (from bottom to top) the vertical geophone on the North OBS ( blue ), the hydrophone module on the...wet end electronics (pressure sensor, hydrophone and octopus ) to the spare J15-3 S/N 14 and re-deployed the transducer and tow body assembly. We then...our wet end electronics (hydrophone, pressure sensor and octopus ) to the S/N 11 unit and re-deployed. The repaired J15-3 S/N 11 unit performed
1983-10-01
exceed a 5-year period. Single-family and multifamily housing will experience both growth and decline cycle impact conditions . Single family housing will... growth and decline cycle impact conditions . A high and significant short-term impact is the result of a required supply of 42 units in 1989 ( growth ...over-design. The model corroborated, however, that expansion is necessary even for existing conditions , much less the 114-person growth expected during
Electrically driven quantum light emission in electromechanically tuneable photonic crystal cavities
NASA Astrophysics Data System (ADS)
Petruzzella, M.; Pagliano, F. M.; Zobenica, Ž.; Birindelli, S.; Cotrufo, M.; van Otten, F. W. M.; van der Heijden, R. W.; Fiore, A.
2017-12-01
A single quantum dot deterministically coupled to a photonic crystal environment constitutes an indispensable elementary unit to both generate and manipulate single-photons in next-generation quantum photonic circuits. To date, the scaling of the number of these quantum nodes on a fully integrated chip has been prevented by the use of optical pumping strategies that require a bulky off-chip laser along with the lack of methods to control the energies of nano-cavities and emitters. Here, we concurrently overcome these limitations by demonstrating electrical injection of single excitonic lines within a nano-electro-mechanically tuneable photonic crystal cavity. When an electrically driven dot line is brought into resonance with a photonic crystal mode, its emission rate is enhanced. Anti-bunching experiments reveal the quantum nature of these on-demand sources emitting in the telecom range. These results represent an important step forward in the realization of integrated quantum optics experiments featuring multiple electrically triggered Purcell-enhanced single-photon sources embedded in a reconfigurable semiconductor architecture.
Determination of the Shock Properties of Ceramic Corbit 98: 98% Alumina
2010-06-01
sapphire or aluminum. A single stage three inch bore gas gun was used to accelerate the projectile for experiments at NPS. Los Alamos National Lab used...stage three inch bore gas gun was used to accelerate the projectile for experiments at NPS. Los Alamos National Lab used a higher performance gun...Gigapascals, one billion pascals of pressure or force per unit area HEL Hugoniot elastic limit LANL Los Alamos National Lab mm Millimeter, or one
Process for Design Optimization of Honeycomb Core Sandwich Panels for Blast Load Mitigation
2012-12-01
experiments. Numerical simulation using a single ‘Y’ cross-sectional unit cell model predicted the crush behavior quite well compared to experiments with...of foil glued together by an adhesive. LS-DYNA is used to carry out the virtual simulation . The foil is modeled by quadrilateral Belytschko-Tsay...aluminum alloy with bilinear isotropic-hardening elastoplastic material model is used for the foil. Since the yield and ultimate strength of the AL5052
Needham, Amy; Cantlon, Jessica F; Ormsbee Holley, Susan M
2006-12-01
The current research investigates infants' perception of a novel object from a category that is familiar to young infants: key rings. We ask whether experiences obtained outside the lab would allow young infants to parse the visible portions of a partly occluded key ring display into one single unit, presumably as a result of having categorized it as a key ring. This categorization was marked by infants' perception of the keys and ring as a single unit that should move together, despite their attribute differences. We showed infants a novel key ring display in which the keys and ring moved together as one rigid unit (Move-together event) or the ring moved but the keys remained stationary throughout the event (Move-apart event). Our results showed that 8.5-month-old infants perceived the keys and ring as connected despite their attribute differences, and that their perception of object unity was eliminated as the distinctive attributes of the key ring were removed. When all of the distinctive attributes of the key ring were removed, the 8.5-month-old infants perceived the display as two separate units, which is how younger infants (7-month-old) perceived the key ring display with all its distinctive attributes unaltered. These results suggest that on the basis of extensive experience with an object category, infants come to identify novel members of that category and expect them to possess the attributes typical of that category.
Mothers' Economic Conditions and Sources of Support in Fragile Families
ERIC Educational Resources Information Center
Kalil, Ariel; Ryan, Rebecca M.
2010-01-01
Rising rates of nonmarital childbirth in the United States have resulted in a new family type, the fragile family. Such families, which include cohabiting couples as well as single mothers, experience significantly higher rates of poverty and material hardship than their married counterparts. Ariel Kalil and Rebecca Ryan summarize the economic…
Pre-Professional Arts Based Service-Learning in Music Education and Art Therapy
ERIC Educational Resources Information Center
Feen-Calligan, Holly; Matthews, Wendy K.
2016-01-01
This article describes a study of art therapy and music education students at a Midwestern university in the United States, who participated in single-semester service-learning assignments prior to their clinical internship or student teaching experience. Undergraduate music teacher-candidates taught music to homeschool students; art therapy…
Jastreboff, P J; Sasaki, C T
1986-11-01
Changes in spontaneous neuronal activity of the inferior colliculus in albino guinea pigs before and after administration of sodium salicylate were analyzed. Animals were anesthetized with pentobarbital, and two microelectrodes separated by a few hundred microns were driven through the inferior colliculus. After collecting a sufficiently large sample of cells, sodium salicylate (450 mg/kg) was injected i.p. and recordings again made 2 h after the injection. Comparison of spontaneous activity recorded before and after salicylate administration revealed highly statistically significant differences (p less than 0.001). After salicylate, the mean rate of the cell population increased from 29 to 83 Hz and the median from 26 to 74 Hz. Control experiments in which sodium salicylate was replaced by saline injection revealed no statistically significant differences in cell discharges. Recordings made during the same experiments from lobulus V of the cerebellar vermis revealed no changes in response to salicylate. The observed changes in single-unit activity due to salicylate administration may represent the first systematic evidence of a tinnituslike phenomenon in animals.
NASA Astrophysics Data System (ADS)
Takmakov, Pavel; McKinney, Collin J.; Carelli, Regina M.; Wightman, R. Mark
2011-07-01
Fast-scan cyclic voltammetry is a unique technique for sampling dopamine concentration in the brain of rodents in vivo in real time. The combination of in vivo voltammetry with single-unit electrophysiological recording from the same microelectrode has proved to be useful in studying the relationship between animal behavior, dopamine release and unit activity. The instrumentation for these experiments described here has two unique features. First, a 2-electrode arrangement implemented for voltammetric measurements with the grounded reference electrode allows compatibility with electrophysiological measurements, iontophoresis, and multielectrode measurements. Second, we use miniaturized electronic components in the design of a small headstage that can be fixed on the rat's head and used in freely moving animals.
Takmakov, Pavel; McKinney, Collin J.; Carelli, Regina M.; Wightman, R. Mark
2011-01-01
Fast-scan cyclic voltammetry is a unique technique for sampling dopamine concentration in the brain of rodents in vivo in real time. The combination of in vivo voltammetry with single-unit electrophysiological recording from the same microelectrode has proved to be useful in studying the relationship between animal behavior, dopamine release and unit activity. The instrumentation for these experiments described here has two unique features. First, a 2-electrode arrangement implemented for voltammetric measurements with the grounded reference electrode allows compatibility with electrophysiological measurements, iontophoresis, and multielectrode measurements. Second, we use miniaturized electronic components in the design of a small headstage that can be fixed on the rat's head and used in freely moving animals. PMID:21806203
The Social Relations of a Health Walk Group: An Ethnographic Study.
Grant, Gordon; Pollard, Nick; Allmark, Peter; Machaczek, Kasia; Ramcharan, Paul
2017-09-01
It is already well established that regular walks are conducive to health and well-being. This article considers the production of social relations of regular, organized weekly group walks for older people. It is based on an ethnographic study of a Walking for Health group in a rural area of the United Kingdom. Different types of social relations are identified arising from the walk experience. The social relations generated are seen to be shaped by organizational factors that are constitutive of the walks; the resulting culture having implications for the sustainability of the experience. As there appears to be no single uniting theory linking group walk experiences to the production of social relations at this time, the findings are considered against therapeutic landscape, therapeutic mobility, and social capital theorizing. Finally, implications for the continuance of walking schemes for older people and for further research are considered.
Sedney, Cara L; Spirou, Eleni; Voelker, Joseph L; Rosen, Charles L
2017-11-01
Resident education in the United States and elsewhere has undergone significant changes in recent years owing to work hour restrictions, requiring didactics to fit within a limited schedule, while being increasingly effective at accomplishing educational goals. A single small program experience in improving the didactic experience of residents is described. Focused mentorship, curricula for intangibles, asynchronous education, and independent curricula all are useful tools in resident education. Residents can be exposed to both clinical material and specialty-specific mores using focused and intentional educational techniques. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Huff, H.; You, Z.; Williams, T.; Nichols, T.; Attia, J.; Fogarty, T. N.; Kirby, K.; Wilkins, R.; Lawton, R.
1998-01-01
As integrated circuits become more sensitive to charged particles and neutrons, anomalous performance due to single event effects (SEE) is a concern and requires experimental verification and quantification. The Center for Applied Radiation Research (CARR) at Prairie View A&M University has developed experiments as a participant in the NASA ER-2 Flight Program, the APEX balloon flight program and the Student Launch Program. Other high altitude and ground level experiments of interest to DoD and commercial applications are being developed. The experiment characterizes the SEE behavior of high speed and high density SRAM's. The system includes a PC-104 computer unit, an optical drive for storage, a test board with the components under test, and a latchup detection and reset unit. The test program will continuously monitor the stored checkerboard data pattern in the SW and record errors. Since both the computer and the optical drive contain integrated circuits, they are also vulnerable to radiation effects. A latchup detection unit with discrete components will monitor the test program and reset the system when necessary. The first results will be obtained from the NASA ER-2 flights, which are now planned to take place in early 1998 from Dryden Research Center in California. The series of flights, at altitudes up to 70,000 feet, and a variety of flight profiles should yield a distribution of conditions for correlating SEES. SEE measurements will be performed from the time of aircraft power-up on the ground throughout the flight regime until systems power-off after landing.
The problem of genesis and systematic of sedimentary units of hydrocarbon reservoirs
NASA Astrophysics Data System (ADS)
Zhilina, E. N.; Chernova, O. S.
2017-12-01
The problem of identifying and ranking sedimentation, facies associations and their constituent parts - lithogenetic types of sedimentary rocks was considered. As a basis for paleo-sedimentary modelling, the author has developed a classification for terrigenous natural reservoirs,that for the first time links separate sedimentological units into a single hierarchical system. Hierarchy ranking levels are based on a compilation of global knowledge and experience in sediment geology, sedimentological study and systematization, and data from deep-well coresrepresentingJurassichydrocarbon-bearing formationsof the southeastern margin of the Western Siberian sedimentary basin.
Evidence for view-invariant face recognition units in unfamiliar face learning.
Etchells, David B; Brooks, Joseph L; Johnston, Robert A
2017-05-01
Many models of face recognition incorporate the idea of a face recognition unit (FRU), an abstracted representation formed from each experience of a face which aids recognition under novel viewing conditions. Some previous studies have failed to find evidence of this FRU representation. Here, we report three experiments which investigated this theoretical construct by modifying the face learning procedure from that in previous work. During learning, one or two views of previously unfamiliar faces were shown to participants in a serial matching task. Later, participants attempted to recognize both seen and novel views of the learned faces (recognition phase). Experiment 1 tested participants' recognition of a novel view, a day after learning. Experiment 2 was identical, but tested participants on the same day as learning. Experiment 3 repeated Experiment 1, but tested participants on a novel view that was outside the rotation of those views learned. Results revealed a significant advantage, across all experiments, for recognizing a novel view when two views had been learned compared to single view learning. The observed view invariance supports the notion that an FRU representation is established during multi-view face learning under particular learning conditions.
Performance evaluation of a modular detector unit for X-ray computed tomography.
Guo, Zhe; Tang, Zhiwei; Wang, Xinzeng; Deng, Mingliang; Hu, Guangshu; Zhang, Hui
2013-04-18
A research prototype CT scanner is currently under development in our lab. One of the key components in this project is the CT detector. This paper describes the design and performance evaluation of the modular CT detector unit for our proposed scanner. It consists of a Photodiode Array Assembly which captures irradiating X-ray photons and converts the energy into electrical current, and a mini Data Acquisition System which performs current integration and converts the analog signal into digital samples. The detector unit can be easily tiled together to form a CT detector. Experiments were conducted to characterize the detector performance both at the single unit level and system level. The noise level, linearity and uniformity of the proposed detector unit were reported and initial imaging studies were also presented which demonstrated the potential application of the proposed detector unit in actual CT scanners.
Five-Year Experience of an Inpatient Palliative Care Unit at an Academic Referral Center.
Shinall, Myrick C; Martin, Sara F; Nelson, Jill; Miller, Richard S; Semler, Matthew W; Zimmerman, Eli E; Noblit, Christy C; Ely, E Wesley; Karlekar, Mohana
2018-01-01
Palliative care units (PCUs) staffed by specialty-trained physicians and nurses have been established in a number of medical centers. The purpose of this study is to review the 5-year experience of a PCU at a large, urban academic referral center. We retrospectively reviewed a prospectively collected database of all admissions to the PCU at Vanderbilt University Medical Center in the first 5 years of its existence, from 2012 through 2017. Over these 5 years, there were 3321 admissions to the PCU. No single underlying disease process accounted for the majority of the patients, but the largest single category of patients were those with malignancy, who accounted for 38% of admissions. Transfers from the intensive care unit accounted for 50% of admissions, with 43% of admissions from a hospital floor and 7% coming from the emergency department or a clinic. Median length of stay in the PCU was 3 days. In hospital deaths occurred for 50% of admitted patients, while 38% of patients were discharged from the PCU to hospice. These data show that a successful PCU is enabled by buy in from a wide variety of referring specialists and by a multidisciplinary palliative care team focused on care of the actively dying patient as well as pain and symptom management, advance care planning, and hospice referral since a large proportion of referred patients do not die in house.
Experimental Study on Relationship between NOx Emission and Fuel Consumption of a Diesel Engine
NASA Astrophysics Data System (ADS)
Ning, Ping; Liu, Chunjiang; Feng, Zhiqiang; Xia, Yijiang
2018-01-01
For YC6112 diesel engine assembled Delphl model single fuel pump electric controlled, in the premise of not changing its overall unit structure parameters of other systems, three different types of camshaft for single pumps, two kinds of fuel injectors, two types of superchargers and some phase shifting angle of different camshafts were chosen to match with the engine precisely, the experiments under thirteen kinds of working conditions for the engine with different matching were carried out, the change regulation between NOX emission and fuel consumption for the engine with different kinds of configurations was analyzed. The experiment results show the NOX emission and fuel consumption can be reduced greatly by configuring proper camshaft, fuel injectors and superchargers with YC6112 diesel engine.
Dunbar, Nancy M; Kreuter, Justin D; Marx-Wood, Cynthia R; Dumont, Larry J; Szczepiorkowski, Zbigniew M
2013-10-01
The platelet (PLT) Pan Genera Detection test (PGD) is a rapid bacterial detection system used to screen PLTs for bacterial contamination. We report a single center 46-month experience with secondary screening of apheresis PLTs by PGD testing. Existing testing records of apheresis PLTs screened by PGD from July 2008 to April 2012 were reviewed. All PLT units were initially screened by routine postcollection culture methods. Secondary screening using PGD was performed for indated PLTs on PLT storage Day 4 and for outdated PLTs on Day 8. A total of 8535 apheresis PLTs were available in inventory during the study period. Of these, 5030 (58.9%) were dispensed and transfused before PGD testing and 3505 (41.1%) underwent PGD testing on Day 4. Twenty-five units tested on Day 4 were PGD initial reactive (0.71%). All were confirmed to be false positive by repeat PGD testing in triplicate (n=20) or by confirmatory culture (n=5). An additional 364 units that were PGD nonreactive on Day 4 were approved for transfusion on Day 6 or Day 7 due to urgent clinical need. A total of 371 outdated units underwent repeat PGD testing before discard on Day 8; all were nonreactive. Secondary PGD testing of culture-screened apheresis PLTs results in low yield in a medium-sized transfusion service. Use of PGD testing on Day 4 may allow for extension of the apheresis PLT shelf life to Day 7 for hospitals that face supply constraints. © 2013 American Association of Blood Banks.
Frank, B S; Lewis, R J
1997-06-01
Accidental extubation is a potentially serious event for pediatric or neonatal patients with respiratory failure, especially in clinical settings in which personnel capable of performing reintubation may not be readily available. Thus the rate of accidental extubation in small intensive care units that operate without 24-hour in-house physician availability may be an important quality assurance indicator. The objective of this study were to determine the accidental extubation rate at a single small pediatric intensive care unit (PICU) and compare it with published reports. This study was carried out in a six-bed PICU at Washoe Medical Center in Reno, Nevada, with a relatively low level of patient acuity, as measured by PRISM score and the frequency of intubation, and without 24-hour in-house physician availability. All intubated patients admitted during the 5-year period from January 1, 1989 to December 31, 1993 were included. The primary outcome measure was the occurrence of accidental extubation. We observed only two accidental extubations in 1,749 intubated-patient-days (IPD) (0.114 accidental extubations/100 IPD [95% confidence interval 0.014-0.413 accidental extubations/ 100 IPD]). This rate of accidental extubation was compared with data in published reports from neonatal intensive care units (NICUs) and PICUs, which ranged from 0.14 accidental extubations/100 IPD to 4.36 accidental extubations/100 IPD. The dependence of the observed accidental extubation rate on unit size and institutional experience with intubated patients, as measured by the average number of intubated patients, was examined. We found no evidence that the accidental extubation rate is higher in smaller units or units with less institutional experience. Low rates can be achieved in small units with low acuity.
Tactile directional sensibility: peripheral neural mechanisms in man.
Olausson, H; Wessberg, J; Kakuda, N
2000-06-02
Tactile directional sensibility, i.e. the ability to tell the direction of an object's motion across the skin, is an easily observed sensory function that is highly sensitive to disturbances of the somatosensory system. Based on previous psychophysical experiments on healthy subjects it was concluded that directional sensibility depends on two kinds of information from cutaneous mechanoreceptors; spatio-temporal information and information about friction-induced changes in skin stretch. In the present study responses to similar probe movements as in the psychophysical experiments were recorded from human single mechanoreceptors in the forearm skin. All slowly adapting type 2 (SA2) units were spontaneously active, and with increasing force of friction their discharge rates were modified by probe movements at increasing distances from the Ruffini end-organ, reflecting the high stretch-sensitivity of these units. Slowly adapting type 1 (SA1) and field units responded to the moving probe within well-defined skin areas directly overlying the individual receptor terminals, and compared to the SA2 units their response properties were less dependent on the force of friction. The results suggest that SA1 and field units have the capacity to signal spatio-temporal information, whereas a population of SA2 units have the capacity to signal direction-specific information about changes in lateral skin stretch.
Photoexcited energy transfer in a weakly coupled dimer
Hernandez, Laura Alfonso; Nelson, Tammie; Tretiak, Sergei; ...
2015-01-08
Nonadiabatic excited-state molecular dynamics (NA-ESMD) simulations have been performed in order to study the time-dependent exciton localization during energy transfer between two chromophore units of the weakly coupled anthracene dimer dithia-anthracenophane (DTA). Simulations are done at both low temperature (10 K) and room temperature (300 K). The initial photoexcitation creates an exciton which is primarily localized on a single monomer unit. Subsequently, the exciton experiences an ultrafast energy transfer becoming localized on either one monomer unit or the other, whereas delocalization between both monomers never occurs. In half of the trajectories, the electronic transition density becomes completely localized on themore » same monomer as the initial excitation, while in the other half, it becomes completely localized on the opposite monomer. In this article, we present an analysis of the energy transfer dynamics and the effect of thermally induced geometry distortions on the exciton localization. Finally, simulated fluorescence anisotropy decay curves for both DTA and the monomer unit dimethyl anthracene (DMA) are compared. As a result, our analysis reveals that changes in the transition density localization caused by energy transfer between two monomers in DTA is not the only source of depolarization and exciton relaxation within a single DTA monomer unit can also cause reorientation of the transition dipole.« less
Photoexcited Energy Transfer in a Weakly Coupled Dimer.
Alfonso Hernandez, Laura; Nelson, Tammie; Tretiak, Sergei; Fernandez-Alberti, Sebastian
2015-06-18
Nonadiabatic excited-state molecular dynamics (NA-ESMD) simulations have been performed in order to study the time-dependent exciton localization during energy transfer between two chromophore units of the weakly coupled anthracene dimer dithia-anthracenophane (DTA). Simulations are done at both low temperature (10 K) and room temperature (300 K). The initial photoexcitation creates an exciton which is primarily localized on a single monomer unit. Subsequently, the exciton experiences an ultrafast energy transfer becoming localized on either one monomer unit or the other, whereas delocalization between both monomers never occurs. In half of the trajectories, the electronic transition density becomes completely localized on the same monomer as the initial excitation, while in the other half, it becomes completely localized on the opposite monomer. In this article, we present an analysis of the energy transfer dynamics and the effect of thermally induced geometry distortions on the exciton localization. Finally, simulated fluorescence anisotropy decay curves for both DTA and the monomer unit dimethyl anthracene (DMA) are compared. Our analysis reveals that changes in the transition density localization caused by energy transfer between two monomers in DTA is not the only source of depolarization and exciton relaxation within a single DTA monomer unit can also cause reorientation of the transition dipole.
Gupta, Priya M; Perrine, Cria G; Chen, Jian; Elam-Evans, Laurie D; Flores-Ayala, Rafael
2017-08-01
Exclusive breastfeeding under 6 months, calculated from a single 24-hour recall among mothers of children 0 to 5 months of age, is a World Health Organization (WHO) indicator used to monitor progress on the 2025 global breastfeeding target. Many upper-middle-income and high-income countries, including the United States, do not have estimates for this indicator. Research aim: To describe the prevalence of exclusive breastfeeding under 6 months in the United States. We used a single 24-hour dietary recall from the National Health and Nutrition Examination Survey 2009-2012 to calculate the prevalence of exclusive breastfeeding under 6 months. We discuss our results in the context of routine breastfeeding surveillance, which is reported from a national survey with different methodology. Among children younger than 6 months, 24.4%, 95% confidence interval [17.6, 31.1], were exclusively breastfed the previous day. To our knowledge, this is the first estimate of the WHO indicator of exclusive breastfeeding under 6 months for the United States. This study supports the global surveillance and data strategy for reporting to the WHO on the 2025 target for exclusive breastfeeding.
Chronic monitoring of lower urinary tract activity via a sacral dorsal root ganglia interface
NASA Astrophysics Data System (ADS)
Khurram, Abeer; Ross, Shani E.; Sperry, Zachariah J.; Ouyang, Aileen; Stephan, Christopher; Jiman, Ahmad A.; Bruns, Tim M.
2017-06-01
Objective. Our goal is to develop an interface that integrates chronic monitoring of lower urinary tract (LUT) activity with stimulation of peripheral pathways. Approach. Penetrating microelectrodes were implanted in sacral dorsal root ganglia (DRG) of adult male felines. Peripheral electrodes were placed on or in the pudendal nerve, bladder neck and near the external urethral sphincter. Supra-pubic bladder catheters were implanted for saline infusion and pressure monitoring. Electrode and catheter leads were enclosed in an external housing on the back. Neural signals from microelectrodes and bladder pressure of sedated or awake-behaving felines were recorded under various test conditions in weekly sessions. Electrodes were also stimulated to drive activity. Main results. LUT single- and multi-unit activity was recorded for 4-11 weeks in four felines. As many as 18 unique bladder pressure single-units were identified in each experiment. Some channels consistently recorded bladder afferent activity for up to 41 d, and we tracked individual single-units for up to 23 d continuously. Distension-evoked and stimulation-driven (DRG and pudendal) bladder emptying was observed, during which LUT sensory activity was recorded. Significance. This chronic implant animal model allows for behavioral studies of LUT neurophysiology and will allow for continued development of a closed-loop neuroprosthesis for bladder control.
PyMUS: Python-Based Simulation Software for Virtual Experiments on Motor Unit System
Kim, Hojeong; Kim, Minjung
2018-01-01
We constructed a physiologically plausible computationally efficient model of a motor unit and developed simulation software that allows for integrative investigations of the input–output processing in the motor unit system. The model motor unit was first built by coupling the motoneuron model and muscle unit model to a simplified axon model. To build the motoneuron model, we used a recently reported two-compartment modeling approach that accurately captures the key cell-type-related electrical properties under both passive conditions (somatic input resistance, membrane time constant, and signal attenuation properties between the soma and the dendrites) and active conditions (rheobase current and afterhyperpolarization duration at the soma and plateau behavior at the dendrites). To construct the muscle unit, we used a recently developed muscle modeling approach that reflects the experimentally identified dependencies of muscle activation dynamics on isometric, isokinetic and dynamic variation in muscle length over a full range of stimulation frequencies. Then, we designed the simulation software based on the object-oriented programing paradigm and developed the software using open-source Python language to be fully operational using graphical user interfaces. Using the developed software, separate simulations could be performed for a single motoneuron, muscle unit and motor unit under a wide range of experimental input protocols, and a hierarchical analysis could be performed from a single channel to the entire system behavior. Our model motor unit and simulation software may represent efficient tools not only for researchers studying the neural control of force production from a cellular perspective but also for instructors and students in motor physiology classroom settings. PMID:29695959
PyMUS: Python-Based Simulation Software for Virtual Experiments on Motor Unit System.
Kim, Hojeong; Kim, Minjung
2018-01-01
We constructed a physiologically plausible computationally efficient model of a motor unit and developed simulation software that allows for integrative investigations of the input-output processing in the motor unit system. The model motor unit was first built by coupling the motoneuron model and muscle unit model to a simplified axon model. To build the motoneuron model, we used a recently reported two-compartment modeling approach that accurately captures the key cell-type-related electrical properties under both passive conditions (somatic input resistance, membrane time constant, and signal attenuation properties between the soma and the dendrites) and active conditions (rheobase current and afterhyperpolarization duration at the soma and plateau behavior at the dendrites). To construct the muscle unit, we used a recently developed muscle modeling approach that reflects the experimentally identified dependencies of muscle activation dynamics on isometric, isokinetic and dynamic variation in muscle length over a full range of stimulation frequencies. Then, we designed the simulation software based on the object-oriented programing paradigm and developed the software using open-source Python language to be fully operational using graphical user interfaces. Using the developed software, separate simulations could be performed for a single motoneuron, muscle unit and motor unit under a wide range of experimental input protocols, and a hierarchical analysis could be performed from a single channel to the entire system behavior. Our model motor unit and simulation software may represent efficient tools not only for researchers studying the neural control of force production from a cellular perspective but also for instructors and students in motor physiology classroom settings.
ERIC Educational Resources Information Center
Yamaguchi, Motonori; Logan, Gordon D.
2016-01-01
Hierarchical control of skilled performance depends on the ability of higher level control to process several lower level units as a single chunk. The present study investigated the development of hierarchical control of skilled typewriting, focusing on the process of memory chunking. In the first 3 experiments, skilled typists typed words or…
1992-09-18
the Environmental Protection Agency (EPA) to dispose of LiSO2 batteries. B. NICKEL CA7)MIUM BATERIES The rechargeable Ni-Cad battery that is suitable...also fairly represent USMC experience with ... d-i bateries . Thereff.,..e, the 213 cycle value was used in the subsequent lead-acid-specific analysis
ERIC Educational Resources Information Center
Whiteside, Aimee L.; Garrett Dikkers, Amy; Lewis, Somer
2016-01-01
This article examined a blended learning initiative in a large suburban high school in the Midwestern region of the United States. It employed a single-case exploratory design approach to learn about the experience of administrators, teachers, students, and parents. Using Zimmerman's Self-Regulated Learning (SRL) Theory as a guiding framework,…
Awiszus, F; Feistner, H; Schäfer, S S
1991-01-01
The peri-stimulus-time histogram (PSTH) analysis of stimulus-related neuronal spike train data is usually regarded as a method to detect stimulus-induced excitations or inhibitions. However, for a fairly regularly discharging neuron such as the human alpha-motoneuron, long-latency modulations of a PSTH are difficult to interpret as PSTH modulations can also occur as a consequence of a modulated neuronal autocorrelation. The experiments reported here were made (i) to investigate the extent to which a PSTH of a human hand-muscle motoneuron may be contaminated by features of the autocorrelation and (ii) to develop methods that display the motoneuronal excitations and inhibitions without such contamination. Responses of 29 single motor units to electrical ulnar nerve stimulation below motor threshold were investigated in the first dorsal interosseous muscle of three healthy volunteers using an experimental protocol capable of demonstrating the presence of autocorrelative modulations in the neuronal response. It was found for all units that the PSTH as well as the cumulative sum (CUSUM) derived from these responses were severely affected by the presence of autocorrelative features. On the other hand, calculating the CUSUM in a slightly modified form yielded--for all units investigated--a neuronal output feature sensitive only to motoneuronal excitations and inhibitions induced by the afferent volley. The price that has to be paid to arrive at such a modified CUSUM (mCUSUM) was a high computational effort prohibiting the on-line availability of this output feature during the experiment. It was found, however, that an interspike interval superposition plot (IISP)--easily obtainable during the experiment--is also free of autocorrelative features.(ABSTRACT TRUNCATED AT 250 WORDS)
de Armas, Héctor Novoa; Peeters, Oswald M; Van den Mooter, Guy; Blaton, Norbert
2007-05-01
A new polymorphic form of Alprazolam (Xanax), 8-chloro-1-methyl-6-phenyl-4H-[1,2,4]triazolo-[4,3-alpha][1,4]benzodiazepine, C(17)H(13)ClN(4), has been investigated by means of X-ray powder diffraction (XRPD), single crystal X-ray diffraction, and differential scanning calorimetry (DSC). This polymorphic form (form III) was obtained during DSC experiments after the exothermic recrystallization of the melt of form I. The crystal unit cell dimensions for form III were determined from diffractometer methods. The monoclinic unit cell found for this polymorph using XRPD after indexing the powder diffractogram was confirmed by the cell parameters obtained from single crystal X-ray diffractometry on a crystal isolated from the DSC pans. The single crystal unit cell parameters are: a = 28.929(9), b = 13.844(8), c = 7.361(3) angstroms, beta = 92.82(3) degrees , V = 2944(2) angstroms(3), Z = 8, space group P2(1) (No.4), Dx = 1.393 Mg/m(3). The structure obtained from single crystal X-ray diffraction was used as initial model for Rietveld refinement on the powder diffraction data of form III. The temperature phase transformations of alprazolam were also studied using high temperature XRPD. A review of the different phases available in the Powder Diffraction File (PDF) database for this drug is described bringing some clarification and corrections. (c) 2007 Wiley-Liss, Inc. and the American Pharmacists Association.
NASA Astrophysics Data System (ADS)
Sanchez, J.
2018-06-01
In this paper, the application and analysis of the asymptotic approximation method to a single degree-of-freedom has recently been produced. The original concepts are summarized, and the necessary probabilistic concepts are developed and applied to single degree-of-freedom systems. Then, these concepts are united, and the theoretical and computational models are developed. To determine the viability of the proposed method in a probabilistic context, numerical experiments are conducted, and consist of a frequency analysis, analysis of the effects of measurement noise, and a statistical analysis. In addition, two examples are presented and discussed.
A Novel Scheme for Bidirectional and Hybrid Quantum Information Transmission via a Seven-Qubit State
NASA Astrophysics Data System (ADS)
Fang, Sheng-hui; Jiang, Min
2018-02-01
In this paper, we present a novel scheme for bidirectional and hybrid quantum information transmission via a seven-qubit state. We demonstrate that under the control of the supervisor two distant participants can simultaneously and deterministically exchange their states with each other no matter whether they know the states or not. In our scheme, Alice can teleport an arbitrary single-qubit state (two-qubit state) to Bob and Bob can prepare a known two-qubit state (single-qubit state) for Alice simultaneously via the control of the supervisor Charlie. Compared with previous studies for single bidirectional quantum teleportation or single bidirectional remote state preparation schemes, our protocol is a kind of hybrid approach for quantum information transmission. Furthermore, it achieves success with unit probability. Notably, since only pauli operations and two-qubit and single-qubit measurements are used in our schemes, it is flexible in physical experiments.
Helland, Magne; Horgen, Gunnar; Kvikstad, Tor Martin; Garthus, Tore; Aarås, Arne
2008-01-01
This study investigated the effect of moving from single-occupancy offices to a landscape environment. Thirty-two visual display unit (VDU) operators reported no significant change in visual discomfort. Lighting conditions and glare reported subjectively showed no significant correlation with visual discomfort. Experience of pain was found to reduce subjectively rated work capacity during VDU tasks. The correlation between visual discomfort and reduced work capacity for single-occupancy offices was rs=.88 (p=.000) and for office landscape rs=.82 (p=.000). Eye blink rate during habitual VDU work was recorded for 12 operators randomly selected from the 32 participants in the office landscape. A marked drop in eye blink rate during VDU work was found compared to eye blink rate during easy conversation. There were no significant changes in pain intensity in the neck, shoulder, forearm, wrist/hand, back or headache (.24
High sensitivity refractive index sensor based on a tapered small core single-mode fiber structure.
Liu, Dejun; Mallik, Arun Kumar; Yuan, Jinhui; Yu, Chongxiu; Farrell, Gerald; Semenova, Yuliya; Wu, Qiang
2015-09-01
A high sensitivity refractive index (RI) sensor based on a tapered small core single-mode fiber (SCSMF) structure sandwiched between two traditional single-mode fibers (SMF28) is reported. The microheater brushing technique was employed to fabricate the tapered fiber structures with different waist diameters of 12.5, 15.0, and 18.8 μm. Experiments demonstrate that the fiber sensor with a waist diameter of 12.5 μm offers the best sensitivity of 19212.5 nm/RIU (RI unit) in the RI range of 1.4304 to 1.4320. All sensors fabricated in this Letter show good linearity in terms of the spectral wavelength shift versus changes in RI. Furthermore, the sensor with the best sensitivity to RI was also used to measure relative humidity (RH) without any coating materials applied to the fiber surface. Experimental results show that the spectral wavelength shift changes exponentially as the RH varies from 60% to 95%. A maximum sensitivity of 18.3 nm per relative humidity unit (RHU) was achieved in the RH range of 90.4% to 94.5% RH.
Crespo, Alejandro C.; Dominguez, Jose M.; Barreiro, Anxo; Gómez-Gesteira, Moncho; Rogers, Benedict D.
2011-01-01
Smoothed Particle Hydrodynamics (SPH) is a numerical method commonly used in Computational Fluid Dynamics (CFD) to simulate complex free-surface flows. Simulations with this mesh-free particle method far exceed the capacity of a single processor. In this paper, as part of a dual-functioning code for either central processing units (CPUs) or Graphics Processor Units (GPUs), a parallelisation using GPUs is presented. The GPU parallelisation technique uses the Compute Unified Device Architecture (CUDA) of nVidia devices. Simulations with more than one million particles on a single GPU card exhibit speedups of up to two orders of magnitude over using a single-core CPU. It is demonstrated that the code achieves different speedups with different CUDA-enabled GPUs. The numerical behaviour of the SPH code is validated with a standard benchmark test case of dam break flow impacting on an obstacle where good agreement with the experimental results is observed. Both the achieved speed-ups and the quantitative agreement with experiments suggest that CUDA-based GPU programming can be used in SPH methods with efficiency and reliability. PMID:21695185
Fron, Eduard; Pilot, Roberto; Schweitzer, Gerd; Qu, Jianqiang; Herrmann, Andreas; Müllen, Klaus; Hofkens, Johan; Van der Auweraer, Mark; De Schryver, Frans C
2008-05-01
The excited state dynamics of two generations perylenediimide chromophores substituted in the bay area with dendritic branches bearing triphenylamine units as well as those of the respective reference compounds are investigated. Using single photon timing and multi-pulse femtosecond transient absorption experiments a direct proof of a reversible charge transfer occurring from the peripheral triphenylamine to the electron acceptor perylenediimide core is revealed. Femtosecond pump-dump-probe experiments provide evidence for the ground state dynamics by populating excited vibronic levels. It is found by the means of both techniques that the rotational isomerization of the dendritic branches occurs on a time scale that ranges up to 1 ns. This time scale of the isomerization depends on the size of the dendritic arms and is similar both in the ground and excited state.
Preliminary disposal limits, plume interaction factors, and final disposal limits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flach, G.
In the 2008 E-Area Performance Assessment (PA), each final disposal limit was constructed as the product of a preliminary disposal limit and a plume interaction factor. The following mathematical development demonstrates that performance objectives are generally expected to be satisfied with high confidence under practical PA scenarios using this method. However, radionuclides that experience significant decay between a disposal unit and the 100-meter boundary, such as H-3 and Sr-90, can challenge performance objectives, depending on the disposed-of waste composition, facility geometry, and the significance of the plume interaction factor. Pros and cons of analyzing single disposal units or multiple disposalmore » units as a group in the preliminary disposal limits analysis are also identified.« less
Westerhof, Gerben J; Whitbourne, Susan Krauss; Freeman, Gillian P
2012-01-01
To study the aging self, that is, conceptions of one's own aging process, in relation to identity processes and self-esteem in the United States and the Netherlands. As the liberal American system has a stronger emphasis on individual responsibility and youthfulness than the social-democratic Dutch system, we expect that youthful and positive perceptions of one's own aging process are more important in the United States than in the Netherlands. Three hundred and nineteen American and 235 Dutch persons between 40 and 85 years participated in the study. A single question on age identity and the Personal Experience of Aging Scale measured aspects of the aging self. The Identity and Experiences Scale measured identity processes and Rosenberg's scale measured self-esteem. A youthful age identity and more positive personal experiences of aging were related to identity processes and self-esteem. These conceptions of one's own aging process also mediate the relation between identity processes and self-esteem. This mediating effect is stronger in the United States than in the Netherlands. As expected, the self-enhancing function of youthful and positive aging perceptions is stronger in the liberal American system than in the social-democratic Dutch welfare system. The aging self should therefore be studied in its cultural context.
Yamaguchi, Motonori; Randle, James M; Wilson, Thomas L; Logan, Gordon D
2017-09-01
Hierarchical control of skilled performance depends on chunking of several lower-level units into a single higher-level unit. The present study examined the relationship between chunking and recognition of trained materials in the context of typewriting. In 3 experiments, participants were trained with typing nonwords and were later tested on their recognition of the trained materials. In Experiment 1, participants typed the same words or nonwords in 5 consecutive trials while performing a concurrent memory task. In Experiment 2, participants typed the materials with lags between repetitions without a concurrent memory task. In both experiments, recognition of typing materials was associated with better chunking of the materials. Experiment 3 used the remember-know procedure to test the recollection and familiarity components of recognition. Remember judgments were associated with better chunking than know judgments or nonrecognition. These results indicate that chunking is associated with explicit recollection of prior typing episodes. The relevance of the existing memory models to chunking in typewriting was considered, and it is proposed that memory chunking improves retrieval of trained typing materials by integrating contextual cues into the memory traces. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
ERIC Educational Resources Information Center
Needham, Amy; Cantlon, Jessica F.; Ormsbee Holley, Susan M.
2006-01-01
The current research investigates infants' perception of a novel object from a category that is familiar to young infants: key rings. We ask whether experiences obtained outside the lab would allow young infants to parse the visible portions of a partly occluded key ring display into one single unit, presumably as a result of having categorized it…
Characterization and Comparison of New Concepts in Neutron Detection
2010-05-12
because a single detector can be reused many times. The TLDs used in this experiment were typical of those used in the United States Navy for dosimetry ...5 1.5.1 TLD . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1.5.2 Bubble Dosimeters . . . . . . . . . . . . . . . . . . . . 5 1.5.3...67 v List of Figures 1.1 TLD card (left) and holder (right). The four sensitive areas are on the card and contain
ERIC Educational Resources Information Center
Chick, Nancy L.; Brame, Cynthia
2015-01-01
This study offers an investigation of three graduate-level SoTL programs offered since 2007 at a mid-size, highly selective, private, research-intensive university in the southeastern United States. We identify patterns in these early experiences with the scholarship of teaching and learning, specifically the choices made while carrying out their…
La Niña, El Niño, and Atlantic Hurricane Damages in the United States
accounting for the most significant societal changes. To normalize past impacts data to 1997 values, losses significantly higher that the U.S. will experience greater impacts because of a larger number of tropical even in a relatively inactive season a single storm can have significant impacts, e.g., Andrew (1992
ERIC Educational Resources Information Center
Rockett, Julia
This lesson is designed to expose high school students to contemporary Indian authors who write in English and to explore some of their common experiences, themes, and sensibilities as found in their works. While designed for use with a 12th grade literature class, the lesson can also be adapted for use as a single unit in a world literature…
Masel, Eva Katharina; Schur, Sophie; Nemecek, Romina; Mayrhofer, Michael; Huber, Patrick; Adamidis, Feroniki; Maehr, Bruno; Unseld, Matthias; Watzke, Herbert Hans; Pirker, Robert
2017-01-01
Palliative care plays a crucial role in the overall management of patients with advanced lung cancer and was shown to lead to clinically meaningful improvement in quality of life, less aggressive endof-life care, and potentially prolonged survival. Here we summarize our single institution experience on palliative care in patients with lung cancer. The data of patients with lung cancer treated at the palliative care unit of the Medical University of Vienna between June 2010 and March 2013 were retrospectively reviewed. Patient characteristics, reasons for admissions, treatment as well as interventions during hospitalization, and clinical outcomes were determined. The study enrolled 91 lung cancer patients, who represented 19.8% of the 460 patients admitted to the palliative care unit. They had the following clinical characteristics: 39% females, 61% males; median age 62 years; median Karnofsky performance status 50%, 92% metastatic disease, 74% non-small cell lung cancer (NSCLC), 19% small-cell lung cancer (SCLC), 7% neuroendocrine carcinomas of the lung. Primary reasons for admission were deterioration of performance status in 40%, uncontrolled cancer-related pain in 38%, dyspnea in 13%, and psychosocial factors in 8% of the patients. Median duration of hospitalization was 16 days (range, 1-101 days). Improvement or stabilisation of tumor-related symptoms was achieved in 25% of the patients. Seventy-five percent of all patients died during their first admission. Their median survival from primary diagnosis until death was 16 months (95% confidence interval, 13.7-18.3 months). Patients with lung cancer admitted to the palliative care unit had late-stage disease. In order to provide early palliative care, the management of lung cancer patients should guarantee access to ambulatory care, inpatient care and home care as well as cooperation and communication between oncologists and palliative care physicians.
In Vivo Imaging of Human Sarcomere Twitch Dynamics in Individual Motor Units.
Sanchez, Gabriel N; Sinha, Supriyo; Liske, Holly; Chen, Xuefeng; Nguyen, Viet; Delp, Scott L; Schnitzer, Mark J
2015-12-16
Motor units comprise a pre-synaptic motor neuron and multiple post-synaptic muscle fibers. Many movement disorders disrupt motor unit contractile dynamics and the structure of sarcomeres, skeletal muscle's contractile units. Despite the motor unit's centrality to neuromuscular physiology, no extant technology can image sarcomere twitch dynamics in live humans. We created a wearable microscope equipped with a microendoscope for minimally invasive observation of sarcomere lengths and contractile dynamics in any major skeletal muscle. By electrically stimulating twitches via the microendoscope and visualizing the sarcomere displacements, we monitored single motor unit contractions in soleus and vastus lateralis muscles of healthy individuals. Control experiments verified that these evoked twitches involved neuromuscular transmission and faithfully reported muscle force generation. In post-stroke patients with spasticity of the biceps brachii, we found involuntary microscopic contractions and sarcomere length abnormalities. The wearable microscope facilitates exploration of many basic and disease-related neuromuscular phenomena never visualized before in live humans. Copyright © 2015 Elsevier Inc. All rights reserved.
Multi-unit Operations in Non-Nuclear Systems: Lessons Learned for Small Modular Reactors
DOE Office of Scientific and Technical Information (OSTI.GOV)
OHara J. M.; Higgins, J.; DAgostino, A.
2012-01-17
The nuclear-power community has reached the stage of proposing advanced reactor designs to support power generation for decades to come. Small modular reactors (SMRs) are one approach to meet these energy needs. While the power output of individual reactor modules is relatively small, they can be grouped to produce reactor sites with different outputs. Also, they can be designed to generate hydrogen, or to process heat. Many characteristics of SMRs are quite different from those of current plants and may be operated quite differently. One difference is that multiple units may be operated by a single crew (or a singlemore » operator) from one control room. The U.S. Nuclear Regulatory Commission (NRC) is examining the human factors engineering (HFE) aspects of SMRs to support licensing reviews. While we reviewed information on SMR designs to obtain information, the designs are not completed and all of the design and operational information is not yet available. Nor is there information on multi-unit operations as envisioned for SMRs available in operating experience. Thus, to gain a better understanding of multi-unit operations we sought the lesson learned from non-nuclear systems that have experience in multi-unit operations, specifically refineries, unmanned aerial vehicles and tele-intensive care units. In this paper we report the lessons learned from these systems and the implications for SMRs.« less
A z-gradient array for simultaneous multi-slice excitation with a single-band RF pulse.
Ertan, Koray; Taraghinia, Soheil; Sadeghi, Alireza; Atalar, Ergin
2018-07-01
Multi-slice radiofrequency (RF) pulses have higher specific absorption rates, more peak RF power, and longer pulse durations than single-slice RF pulses. Gradient field design techniques using a z-gradient array are investigated for exciting multiple slices with a single-band RF pulse. Two different field design methods are formulated to solve for the required current values of the gradient array elements for the given slice locations. The method requirements are specified, optimization problems are formulated for the minimum current norm and an analytical solution is provided. A 9-channel z-gradient coil array driven by independent, custom-designed gradient amplifiers is used to validate the theory. Performance measures such as normalized slice thickness error, gradient strength per unit norm current, power dissipation, and maximum amplitude of the magnetic field are provided for various slice locations and numbers of slices. Two and 3 slices are excited by a single-band RF pulse in simulations and phantom experiments. The possibility of multi-slice excitation with a single-band RF pulse using a z-gradient array is validated in simulations and phantom experiments. Magn Reson Med 80:400-412, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Single-Incision Laparoscopic Total Colectomy
Ojo, Oluwatosin J.; Carne, David; Guyton, Daniel
2012-01-01
Background and Objectives: To present our experience with a single-incision laparoscopic total colectomy, along with a literature review of all published cases on single-incision laparoscopic total colectomy. Methods: A total of 22 cases were published between 2010 and 2011, with our patient being case 23. These procedures were performed in the United States and United Kingdom. Surgical procedures included total colectomy with end ileostomy, proctocolectomy with ileorectal anastomosis, and total proctocolectomy with ileopouch-anal anastomosis. Intraoperative and postoperative data are analyzed. Results: Twenty-two of the 23 cases were performed for benign cases including Crohns, ulcerative colitis, and familial adenomatous polyposis. One case was performed for adenocarcinoma of the cecum. The mean age was 35.3 years (range, 13 to 64), the mean body mass index was 20.1 (range, 19 to 25), mean operative time was 175.9 minutes (range, 139 to 216), mean blood loss was 95.3mL (range, 59 to 200), mean incision length was 2.61cm (range, 2 to 3). Average follow-up was 4.6 months with 2 reported complications. Conclusions: Single-incision laparoscopic total colectomy is feasible and safe in the hands of an experienced surgeon. It has been performed for both benign and malignant cases. It is comparable to the conventional multi-port laparoscopic total colectomy. PMID:22906326
Removal of bacteria from stallion semen by colloid centrifugation.
Morrell, J M; Klein, C; Lundeheim, N; Erol, E; Troedsson, M H T
2014-02-01
Bacteria (environmental contaminants and occasionally potential pathogens) are found in most stallion ejaculates and may negatively affect sperm quality during storage. Since the use of antibiotics can lead to the development of resistance, an alternative means of microbial control is desirable. The removal of bacteria from stallion semen using Single Layer Centrifugation through Androcoll-E was investigated. Known doses of cultured bacteria were added to freshly collected ejaculates (15mL aliquots) before processing by Single Layer Centrifugation. The resulting sperm pellets and controls (not processed by Single Layer Centrifugation) were cultured and the bacteria identified. In experiment 1, doses of E. coli from 2×10(2) to 2×10(7) colony forming units were added to aliquots of semen. In experiment 2, Taylorella equigenitalis or a mix of E. coli, Klebsiella pneumoniae and Streptococcus equi subsp. zooepidemicus (approximately 7×10(6), 5×10(6), and 6×10(6)cfu, respectively) were added to 15mL aliquots of semen. In experiment 1, more than 90% of the bacteria were removed where loading doses were >×10(4)cfu/mL. In experiment 2, varying proportions of different bacteria were removed, ranging from 68% for naturally occurring Corynebacterium spp. to >97% for added cultured E. coli. Thus, Single Layer Centrifugation can separate spermatozoa from many, but not all bacteria in stallion ejaculates and could be a useful alternative to adding antibiotics to semen extenders to control bacterial contamination. However, further research is needed to determine the effect of small numbers of bacteria on sperm quality. Copyright © 2014 Elsevier B.V. All rights reserved.
Promoting social welfare through oral health: New Jersey's fluoridation experience.
Mendoza, Roger Lee
2009-01-01
This study examines the contentious public health policy of treating community water with fluoride in the United States. The question for scholarly investigation is why water fluoridation has been unsuccessful in several parts of the United States relative to the rest. It addresses this question by looking into the processes of scientific discovery and information dissemination, benefits and risks of science-based health policy, related issues of provision and production, and spatial dimensions of policy development. The case method based on New Jersey's experience in public water fluoridation, was opted for this study. We find that policy debates, which are confined to single key issues, tend to breed binary choices and bipolar debates and result in policy stalemates. Consumer accessibility and desirability of merit goods thus become sharply conflicting social welfare values. They undermine the intent of science-based policies and often make alternative and second-best policies more practical to adopt.
A Complete OCR System for Tamil Magazine Documents
NASA Astrophysics Data System (ADS)
Kokku, Aparna; Chakravarthy, Srinivasa
We present a complete optical character recognition (OCR) system for Tamil magazines/documents. All the standard elements of OCR process like de-skewing, preprocessing, segmentation, character recognition, and reconstruction are implemented. Experience with OCR problems teaches that for most subtasks of OCR, there is no single technique that gives perfect results for every type of document image. We exploit the ability of neural networks to learn from experience in solving the problems of segmentation and character recognition. Text segmentation of Tamil newsprint poses a new challenge owing to its italic-like font type; problems that arise in recognition of touching and close characters are discussed. Character recognition efficiency varied from 94 to 97% for this type of font. The grouping of blocks into logical units and the determination of reading order within each logical unit helped us in reconstructing automatically the document image in an editable format.
Porting a Hall MHD Code to a Graphic Processing Unit
NASA Technical Reports Server (NTRS)
Dorelli, John C.
2011-01-01
We present our experience porting a Hall MHD code to a Graphics Processing Unit (GPU). The code is a 2nd order accurate MUSCL-Hancock scheme which makes use of an HLL Riemann solver to compute numerical fluxes and second-order finite differences to compute the Hall contribution to the electric field. The divergence of the magnetic field is controlled with Dedner?s hyperbolic divergence cleaning method. Preliminary benchmark tests indicate a speedup (relative to a single Nehalem core) of 58x for a double precision calculation. We discuss scaling issues which arise when distributing work across multiple GPUs in a CPU-GPU cluster.
Wireless multi-channel single unit recording in freely moving and vocalizing primates
Roy, Sabyasachi; Wang, Xiaoqin
2011-01-01
The ability to record well-isolated action potentials from individual neurons in naturally behaving animals is crucial for understanding neural mechanisms underlying natural behaviors. Traditional neurophysiology techniques, however, require the animal to be restrained which often restricts natural behavior. An example is the common marmoset (Callithrix jacchus), a highly vocal New World primate species, used in our laboratory to study the neural correlates of vocal production and sensory feedback. When restrained by traditional neurophysiological techniques marmoset vocal behavior is severely inhibited. Tethered recording systems, while proven effective in rodents pose limitations in arboreal animals such as the marmoset that typically roam in a three-dimensional environment. To overcome these obstacles, we have developed a wireless neural recording technique that is capable of collecting single-unit data from chronically implanted multi-electrodes in freely moving marmosets. A lightweight, low power and low noise wireless transmitter (headstage) is attached to a multi-electrode array placed in the premotor cortex of the marmoset. The wireless headstage is capable of transmitting 15 channels of neural data with signal-to-noise ratio (SNR) comparable to a tethered system. To minimize radio-frequency (RF) and electro-magnetic interference (EMI), the experiments were conducted within a custom designed RF/EMI and acoustically shielded chamber. The individual electrodes of the multi-electrode array were periodically advanced to densely sample the cortical layers. We recorded single-unit data over a period of several months from the frontal cortex of two marmosets. These recordings demonstrate the feasibility of using our wireless recording method to study single neuron activity in freely roaming primates. PMID:21933683
Gofrit, Ofer N; Orvieto, Marcelo A; Zorn, Kevin C; Steinberg, Gary D; Zagaja, Gregory P; Shalhav, Arieh L
2009-02-01
Single renal unit models are invaluable for studies in renal physiology, transplantation and response to ischemic injury. Glomerular filtration rate (GFR) is commonly used for evaluation of renal function. Measuring the GFR involves relatively complicated and expensive systems. In this study we determined whether serum creatinine (Scr) can predict the GFR in this model. Right laparoscopic nephrectomy was performed in 46 female pigs weighing 25 kg-30 kg. Twelve days later the left kidney was exposed to various periods of warm ischemia (30, 60, 90, and 120 minutes). Scr and GFR (using the iohexol clearance method) were determined preoperatively and at postoperative days 1, 3, 8, 15, 22 and 29. A total of 244 pairs of Scr and GFR values were analyzed to determine a formula for predicting GFR (pGFR) from Scr. Scr range was 1.2 mg/dl -29 mg/dl and GFR range was 1.8 ml/min -180.5 ml/min. The empiric formula deduced from the database for calculating pGFR from Scr was: pGFR = (217 divided by Scr) minus 0.2. pGFR correlated well with the actual GFR (R(2) = 0.85). The graphs for pGFR were almost indistinguishable from the graphs for actual GFR in every single animal. The results and conclusions of the experiments using either actual or predicted GFR were identical. We conclude that in a single renal unit porcine model using ischemia as the insult to the kidney, expensive actual measurements of GFR can be reliably replaced by Scr based calculated GFR.
NASA Astrophysics Data System (ADS)
Lyu, WeiChao; Wang, Andong; Xie, Dequan; Zhu, Long; Guan, Xun; Wang, Jian; Xu, Jing
2018-05-01
We propose a novel architecture for wavelength-division-multiplexed passive optical network (WDM-PON) that can simultaneously circumvent both remodulation crosstalk and Rayleigh noise, based on self-homodyne detection and optical orthogonal frequency-division multiplexing (OFDM) remodulation. The proposed self-homodyne detection at optical network unit (ONU) requires neither frequency offset compensation nor phase noise compensation, and thus can significantly reduce system complexity and power consumption. Bidirectional transmission of 12.5 Gb/s down- and up-stream signals, via single 25 km single-mode fiber without dispersion compensation, is demonstrated in a proof-of-concept experiment.
ERIC Educational Resources Information Center
Goings, Ramon B.; Davis, Julius; Britto, Joseph; Greene, Dijaria
2017-01-01
There has been a national- and state-level call for colleges and universities to develop targeted mentoring programs for Black males. However, there is limited published scholarship that has investigated the experiences of non-U.S.-born Black males in these college mentoring programs generally, and at historically Black colleges and universities…
A 40-kW fuel cell field test summary utilities activities report
NASA Astrophysics Data System (ADS)
Racine, W. C.; Londos, T. C.
1987-07-01
Forty six 40 kW fuel cell power plants were field tested by 37 host participants at 42 sites in a variety of commercial, light industrial and multifamily residential applications. The participants obtained over 300,000 hours of operating experience with the power plants covering a diverse range of applications for power plant electricity and heat utilization in both single and multiple unit installations.
Development of biostereometric experiments. [stereometric camera system
NASA Technical Reports Server (NTRS)
Herron, R. E.
1978-01-01
The stereometric camera was designed for close-range techniques in biostereometrics. The camera focusing distance of 360 mm to infinity covers a broad field of close-range photogrammetry. The design provides for a separate unit for the lens system and interchangeable backs on the camera for the use of single frame film exposure, roll-type film cassettes, or glass plates. The system incorporates the use of a surface contrast optical projector.
The interplay between cooperativity and diversity in model threshold ensembles
Cervera, Javier; Manzanares, José A.; Mafe, Salvador
2014-01-01
The interplay between cooperativity and diversity is crucial for biological ensembles because single molecule experiments show a significant degree of heterogeneity and also for artificial nanostructures because of the high individual variability characteristic of nanoscale units. We study the cross-effects between cooperativity and diversity in model threshold ensembles composed of individually different units that show a cooperative behaviour. The units are modelled as statistical distributions of parameters (the individual threshold potentials here) characterized by central and width distribution values. The simulations show that the interplay between cooperativity and diversity results in ensemble-averaged responses of interest for the understanding of electrical transduction in cell membranes, the experimental characterization of heterogeneous groups of biomolecules and the development of biologically inspired engineering designs with individually different building blocks. PMID:25142516
Design and Test of a Soft Plantar Force Measurement System for Gait Detection
Zhang, Xuefeng; Zhao, Yulong; Duan, Zhengyong; Liu, Yan
2012-01-01
This work describes a plantar force measurement system. The MEMS pressure sensor, as the key sensing element, is designed, fabricated and embedded into a flexible silicon oil-filled bladder made of silicon rubber to constitute a single sensing unit. A conditioning circuit is designed for signal processing and data acquisition. The characteristics of the plantar force sensing unit are investigated by both static and dynamic tests. A comparison of characteristics between the proposed plantar force sensing unit and a commercial flexible force sensor is presented. A practical experiment of plantar force measurement has been carried out to validate the system. The results demonstrate that the proposed measurement system has a potential for success in the application of plantar force measurement during normal gait. PMID:23208558
The use and nature of grapheme coding during sub-lexical processing and lexical access.
Commissaire, Eva; Casalis, Séverine
2018-06-01
This work aimed to investigate grapheme coding during sub-lexical processing and lexical access. Using the letter detection task in Experiment 1, we compared letter pairs that could be considered as a grapheme unit or not depending on context (referred to as weakly cohesive complex, e.g., an in chant vs cane) to real two-letter graphemes (highly cohesive complex, e.g., au in chaud) and single-letter graphemes (simple, e.g., a in place). Three experimental conditions were used, one of which was designed to prevent phonological influences. Data revealed that only highly cohesive complex graphemes were processed as units, not the weakly cohesive ones. The same pattern was found across experimental conditions in favor of an orthographic mechanism. In Experiments 2 and 3, a primed lexical decision task was used with two stimulus onset asynchronies (SOAs) and two different ranges of lexical frequency. We manipulated the number of graphemes removed from partial primes ( d**che vs do**he-DOUCHE) and relatedness. In contrast to Experiment 1, no evidence was provided in favor of a role of graphemes during lexical access. We suggest that graphemes can be conceived as sub-lexical orthographic units per se but can only be captured within a sub-lexical route to reading.
Deterministic Multi-hop Controlled Teleportation of Arbitrary Single-Qubit State
NASA Astrophysics Data System (ADS)
Peng, Jia-yin; Bai, Ming-qiang; Mo, Zhi-wen
2017-10-01
Multi-hop teleportation is of great significance due to long-distance delivery of quantum information and wireless quantum communication networks. In existing protocols of multi-hop teleportation, the more nodes, the smaller the success probability. In this paper, fusing the ideas of multi-hop teleportation and controlled teleportation, we put forward a scheme for implementing multi-hop controlled teleportation of single-qubit state. A set of ingenious three-qubit non-maximally entangled states are constructed to serve as the quantum channels. The information is perfectly transmitted hop by hop through teleportation under the control of the supervisors. Unit success probability can be achieved independent of channel's entanglement degree and the number of intermediate nodes. Only Pauli operations, single-qubit rotation, Hadamard gate, controlled-NOT gate, Bell-state measurement and single-qubit measurement are used in our scheme, so this scheme is easily realized in physical experiment.
Bingler, Michael; Erickson, Lori A; Reid, Kimberly J; Lee, Brian; O'Brien, James; Apperson, Johnathan; Goggin, Kathy; Shirali, Girish
2018-05-01
Interstage outcomes for infants with single ventricle remain suboptimal. We have previously described a tablet PC-based platform Cardiac High Acuity Monitoring Program (CHAMP) for remote monitoring which provides immediate access to data, videos, and instant alerts to our single ventricle care team. This study compares traditional three-ring binder monitoring (Binder) to CHAMP using a randomized crossover design to evaluate mortality, resource utilization, and caregiver experience. At discharge, all single ventricle infants were monitored using Binder and randomized to receive CHAMP at either one or two months postdischarge. One month after randomization, caregivers could choose either Binder or CHAMP for the remainder of the interstage period. Caregivers experience was recorded using surveys. Enrollment included 31 single ventricle infants from May 2014 to June 2015. There was no interstage mortality over 4,911 total interstage days (median: 144/patient). Of 73 readmissions, 45 were unplanned. Of the initial 23 unplanned readmissions, 13 were found to have been based on data obtained exclusively through CHAMP (as instant alerts or based on data review) rather than caregiver concerns. Due to concerns regarding patient safety, additional enrollment was stopped. The CHAMP use was associated with significantly fewer unplanned intensive care unit days/100 interstage days, shorter delays in care, lower resource utilization at readmissions, and lower incidence of interstage growth failure and was preferred by a majority of caregivers. These findings suggest that CHAMP may offer benefits over Binder (improved interstage outcomes, delays in care, and caregiver experience). These findings should be tested across multiple centers in larger populations.
Haws, Melinda J; Schwartz, Michael R; Berger, Lewis H; Daulton, Kimber L
2014-07-01
The Sientra portfolio of silicone gel breast implants was approved by the Food and Drug Administration on March 9, 2012, and included the first approved shaped implants in the United States. The 5-year results from Sientra's Core Gel and Continued Access Study and the results of a single surgeon are presented. This analysis used the data of 640 shaped implants in 321 primary augmentation patients implanted by 16 study surgeons through 5 years. The Kaplan-Meier method was used to analyze safety endpoints. In addition, analysis is presented for a single surgeon's results of 213 shaped implants in 108 postapproval patients through up to 16 months of follow-up (9-month mean) using a separate frequency analysis. The overall risk of rupture for primary augmentation patients through 5 years was 0.4%, the risk of infection was 1.4%, and the risk of capsular contracture (Baker grade III/IV) was 3.9%. Reported surgeon satisfaction was 100%, and patient satisfaction remained high. In the separate single-surgeon analysis, after 16 months, 4 of the 108 patients experienced a complication (3.7%) and 3 underwent a reoperation (2.8%). Complications included infection, ptosis (0.9%, each), and capsular contracture (1.9%). The results of Sientra's large clinical study and the postapproval data from a single surgeon demonstrate the safety and effectiveness of Sientra's shaped implants. The review of the data and author's experience illustrate the ease of incorporating shaped implants into any surgical practice.
In Vivo Imaging of Human Sarcomere Twitch Dynamics in Individual Motor Units
Sanchez, Gabriel N.; Sinha, Supriyo; Liske, Holly; Chen, Xuefeng; Nguyen, Viet; Delp, Scott L.; Schnitzer, Mark J.
2017-01-01
SUMMARY Motor units comprise a pre-synaptic motor neuron and multiple post-synaptic muscle fibers. Many movement disorders disrupt motor unit contractile dynamics and the structure of sarcomeres, skeletal muscle’s contractile units. Despite the motor unit’s centrality to neuromuscular physiology, no extant technology can image sarcomere twitch dynamics in live humans. We created a wearable microscope equipped with a microendoscope for minimally invasive observation of sarcomere lengths and contractile dynamics in any major skeletal muscle. By electrically stimulating twitches via the microendoscope and visualizing the sarcomere displacements, we monitored single motor unit contractions in soleus and vastus lateralis muscles of healthy individuals. Control experiments verified that these evoked twitches involved neuromuscular transmission and faithfully reported muscle force generation. In post-stroke patients with spasticity of the biceps brachii, we found involuntary microscopic contractions and sarcomere length abnormalities. The wearable microscope facilitates exploration of many basic and disease-related neuromuscular phenomena never visualized before in live humans. PMID:26687220
NASA Astrophysics Data System (ADS)
Wang, Xiaoliang; Chen, Daru; Li, Haitao; Wu, Qiong
2018-04-01
A novel method to artificially control the backscattering of the single-mode fiber (SMF) is proposed and investigated for the first time. This method can help to fabricate a high backscattering fiber (HBSF), such as by fabricating reflectors in every one meter interval of an SMF based on the exposure of the femtosecond laser beam. The artificially controlled backscattering (ACBS) can be much higher than the natural Rayleigh backscattering (RB) of the SMF. The RB power and ACBS power in the unit length fiber are derived according to the theory of the RBS. The total relative power and the relative back power reflected in the unit length of the HBSF have been simulated and presented. The simulated results show that the HBSF has the characteristics of both low optical attenuation and high backscattering. The relative back power reflected in the unit length of the HBSF is 25dB larger than the RB power of the SMF when the refractive index modulation quantity of the reflectors is 0.009. Some preliminary experiments also indicate that the method fabricating reflectors to increase the backscattering power of the SMF is practical and promising.
Refractive index sensor based on a polymer fiber directional coupler for low index sensing.
Lee, Kwang Jo; Liu, Xiaoqi; Vuillemin, Nelly; Lwin, Richard; Leon-Saval, Sergio G; Argyros, Alexander; Kuhlmey, Boris T
2014-07-14
We propose, numerically analyze and experimentally demonstrate a novel refractive index sensor specialized for low index sensing. The device is based on a directional coupler architecture implemented in a single microstructured polymer optical fiber incorporating two waveguides within it: a single-mode core and a satellite waveguide consisting of a hollow high-index ring. This hollow channel is filled with fluid and the refractive index of the fluid is detected through changes to the wavelength at which resonant coupling occurs between the two waveguides. The sensor design was optimized for both higher sensitivity and lower detection limit, with simulations and experiments demonstrating a sensitivity exceeding 1.4 × 10(3) nm per refractive index unit. Simulations indicate a detection limit of ~2 × 10(-6) refractive index units is achievable. We also numerically investigate the performance for refractive index changes localized at the surface of the holes, a case of particular importance for biosensing.
Does a specialist unit improve outcomes for hospitalized patients with Parkinson's disease?
Skelly, Rob; Brown, Lisa; Fakis, Apostolos; Kimber, Lindsey; Downes, Charlotte; Lindop, Fiona; Johnson, Clare; Bartliff, Caroline; Bajaj, Nin
2014-01-01
Objective Suboptimal management of Parkinson's disease (PD) medication in hospital may lead to avoidable complications. We introduced an in-patient PD unit for those admitted urgently with general medical problems. We explored the effect of the unit on medication management, length of stay and patient experience. Methods We conducted a single-center prospective feasibility study. The unit's core features were defined following consultation with patients and professionals: specially trained staff, ready availability of PD drugs, guidelines, and care led by a geriatrician with specialty PD training. Mandatory staff training comprised four 1 h sessions: PD symptoms; medications; therapy; communication and swallowing. Most medication was prescribed using an electronic Prescribing and Administration system (iSOFT) which provided accurate data on time of administration. We compared patient outcomes before and after introduction of the unit. Results The general ward care (n = 20) and the Specialist Parkinson's Unit care (n = 24) groups had similar baseline characteristics. On the specialist unit: less Parkinson's medication was omitted (13% vs 20%, p < 0.001); of the medication that was given, more was given on time (64% vs 50%, p < 0.001); median length of stay was shorter (9 days vs 13 days, p = 0.043) and patients' experience of care was better (p = 0.01). Discussion If replicated and generalizable to other hospitals, reductions in length of stay would lead to significant cost savings. The apparent improved outcomes with Parkinson's unit care merit further investigation. We hope to test the hypothesis that specialized units are cost-effective and improve patient care using a randomized controlled trial design. PMID:25264022
Prototype detection unit for the CHIPS experiment
NASA Astrophysics Data System (ADS)
Pfützner, Maciej M.
2017-09-01
CHIPS (CHerenkov detectors In mine PitS) is an R&D project aiming to develop novel cost-effective neutrino detectors, focused on measuring the CP-violating neutrino mixing phase (δ CP). A single detector module, containing an enclosed volume of purified water, would be submerged in an existing lake, located in a neutrino beam. A staged approach is proposed with first detectors deployed in a flooded mine pit in Northern Minnesota, 7 mrad off-axis from the existing NuMI beam. A small proof-of-principle model (CHIPS-M) has already been tested and the first stage of a fully functional 10 kt module (CHIPS-10) is planned for 2018. One of the instruments submerged on board of CHIPS-M in autumn 2015 was a prototype detection unit, constructed at Nikhef. The unit contains hardware borrowed from the KM3NeT experiment, including 16 3 inch photomultiplier tubes and readout electronics. In addition to testing the mechanical design and data acquisition, the detector was used to record a large sample of cosmic ray muon events. The collected data is valuable for characterising the cosmic muon background and validating a Monte Carlo simulation used to optimise future designs. This paper introduces the CHIPS project, describes the design of the prototype unit, and presents the results of a preliminary data analysis.
[Organizational wellbeing in the health sector: the Piemonte Region experience].
Converso, Daniela; Baratti, Alberto
2010-01-01
In 2007, the Health Councillorship of the Piedmont region announced, in convention with the Psychology Department of the University of Turin, of the creation of "Workgroup for Safeguard of Organizational Wellbeing" composed by psychologists, occupational doctors, and superintendents for Prevention and Protection services. This group is aimed at promoting pilot experiences in the Health Units in order to prevent and combat psychosocial discomfort and to sustain workers' wellbeing. A complex intervention started in January 2009 and involved the personnel from Services for the Organization and Development of Human Resources, Personnel Services, Services for Occupational Medicine, Services of Communication, Quality Services, belonging to all of the Health Units from Piedmont, and of some structures operating within the national health service, for a total of 23 work groups. Based on the results produced and/or from the shared reflections in the classroom between the 23 groups, four main themes were singled out, corresponding to different levels and fields of interventions, in order to favour the contrast of psychosocial distress and to promote a culture of wellbeing, were adopted taking into account needs and cultural specificity of different Units' realities. The activities embarked on, inside every main theme represent, in the expectations of all the participants, good practices that could be spread to the different Local Health Units.
45 CFR 302.12 - Single and separate organizational unit.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 45 Public Welfare 2 2011-10-01 2011-10-01 false Single and separate organizational unit. 302.12... (CHILD SUPPORT ENFORCEMENT PROGRAM), ADMINISTRATION FOR CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES STATE PLAN REQUIREMENTS § 302.12 Single and separate organizational unit. (a) The State...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-25
... TENNESSEE VALLEY AUTHORITY Final Supplemental Environmental Impact Statement, Single Nuclear Unit... Environmental Impact Statement for a Single Nuclear Unit at the Bellefonte Plant Site (final SEIS) on September... the ROD. TVA prepared the final SEIS to update the extensive environmental information and analyses...
New Technology Changing The Face of Mobile Seismic Networks
NASA Astrophysics Data System (ADS)
Brisbourne, A.; Denton, P.; Seis-Uk
SEIS-UK, a seismic equipment pool and data management facility run by a consortium of four UK universities (Leicester, Leeds, Cambridge and Royal Holloway, London) completed its second phase in 2001. To compliment the existing broadband equipment pool, which has been deployed to full capacity to date, the consortium undertook a tender evaluation process for low-power, lightweight sensors and recorders, for use on both controlled source and passive seismic experiments. The preferred option, selected by the consortium, was the Guralp CMG-6TD system, with 150 systems ordered. The CMG-6TD system is a new concept in temporary seismic equipment. A 30s- 100Hz force-feedback sensor, integral 24bit digitiser and 3-4Gbyte of solid-state memory are all housed in a single unit. Use of the most recent technologies has kept the power consumption to below 1W and the weight to 3.5Kg per unit. The concept of the disk-swap procedure for obtaining data from the field has been usurped by a fast data download technique using firewire technology. This allows for rapid station servicing, essential when 150 stations are in use, and also ensures the environmental integrity of the system by removing the requirement for a disk access port and envi- ronmentally exposed data disk. The system therefore meets the criteria for controlled source and passive seismic experiments: (1) the single unit concept and low-weight is designed for rapid deployment on short-term projects; (2) the low power consumption reduces the power-supply requirements facilitating deployment; (3) the low self-noise and bandwidth of the sensor make it applicable to passive experiments involving nat- ural sources. Further to this acquisition process, in collaboration with external groups, the SEIS- UK data management procedures have been streamlined with the integration of the Guralp GCF format data into the PASSCAL PDB software. This allows for rapid dissemination of field data and the production of archive-ready datasets, reducing the time between field recording and data archive. The archiving procedure for SEIS- UK datasets has been established, with data from experiments carried out with the broadband equipment already on the permanent continuous data archive at IRIS DMC.
The interplay between cooperativity and diversity in model threshold ensembles.
Cervera, Javier; Manzanares, José A; Mafe, Salvador
2014-10-06
The interplay between cooperativity and diversity is crucial for biological ensembles because single molecule experiments show a significant degree of heterogeneity and also for artificial nanostructures because of the high individual variability characteristic of nanoscale units. We study the cross-effects between cooperativity and diversity in model threshold ensembles composed of individually different units that show a cooperative behaviour. The units are modelled as statistical distributions of parameters (the individual threshold potentials here) characterized by central and width distribution values. The simulations show that the interplay between cooperativity and diversity results in ensemble-averaged responses of interest for the understanding of electrical transduction in cell membranes, the experimental characterization of heterogeneous groups of biomolecules and the development of biologically inspired engineering designs with individually different building blocks. © 2014 The Author(s) Published by the Royal Society. All rights reserved.
Letter-case information and the identification of brand names.
Perea, Manuel; Jiménez, María; Talero, Fernanda; López-Cañada, Soraya
2015-02-01
A central tenet of most current models of visual-word recognition is that lexical units are activated on the basis of case-invariant abstract letter representations. Here, we examined this assumption by using a unique type of words: brand names. The rationale of the experiments is that brand names are archetypically printed either in lowercase (e.g., adidas) or uppercase (e.g., IKEA). This allows us to present the brand names in their standard or non-standard case configuration (e.g., adidas, IKEA vs. ADIDAS, ikea, respectively). We conducted two experiments with a brand-decision task ('is it a brand name?'): a single-presentation experiment and a masked priming experiment. Results in the single-presentation experiment revealed faster identification times of brand names in their standard case configuration than in their non-standard case configuration (i.e., adidas faster than ADIDAS; IKEA faster than ikea). In the masked priming experiment, we found faster identification times of brand names when they were preceded by an identity prime that matched its standard case configuration than when it did not (i.e., faster response times to adidas-adidas than to ADIDAS-adidas). Taken together, the present findings strongly suggest that letter-case information forms part of a brand name's graphemic information, thus posing some limits to current models of visual-word recognition. © 2014 The British Psychological Society.
Edenharter, Günther M; Gartner, Daniel; Pförringer, Dominik
2017-06-01
Increasing costs of material resources challenge hospitals to stay profitable. Particularly in anesthesia departments and intensive care units, bronchoscopes are used for various indications. Inefficient management of single- and multiple-use systems can influence the hospitals' material costs substantially. Using mathematical modeling, we developed a strategic decision support tool to determine the optimum mix of disposable and reusable bronchoscopy devices in the setting of an intensive care unit. A mathematical model with the objective to minimize costs in relation to demand constraints for bronchoscopy devices was formulated. The stochastic model decides whether single-use, multi-use, or a strategically chosen mix of both device types should be used. A decision support tool was developed in which parameters for uncertain demand such as mean, standard deviation, and a reliability parameter can be inserted. Furthermore, reprocessing costs per procedure, procurement, and maintenance costs for devices can be parameterized. Our experiments show for which demand pattern and reliability measure, it is efficient to only use reusable or disposable devices and under which circumstances the combination of both device types is beneficial. To determine the optimum mix of single-use and reusable bronchoscopy devices effectively and efficiently, managers can enter their hospital-specific parameters such as demand and prices into the decision support tool.The software can be downloaded at: https://github.com/drdanielgartner/bronchomix/.
Conformity of commercial oral single solid unit dose packages in hospital pharmacy practice.
Thibault, Maxime; Prot-Labarthe, Sonia; Bussières, Jean-François; Lebel, Denis
2008-06-01
There are limited published data on the labelling of single unit dose packages in hospitals. The study was conducted in three large hospitals (two adult and one paediatric) in the metropolitan Montreal area, Quebec, Canada. The objective is to evaluate the labelling of commercial oral single solid unit dose packages available in Canadian urban hospital pharmacy practice. The study endpoint was the labelling conformity of each unit dose package for each criterion and overall for each manufacturer. Complete labelling of unit dose packages should include the following information: (1) brand name, (2) international non-proprietary name or generic name, (3) dosage, (4) pharmaceutical form, (5) manufacturer's name, (6) expiry date, (7) batch number and (8) drug identification number. We also evaluated the ease with which a single unit dose package is detached from a multiple unit dose package for quick, easy and safe use by pharmacy staff. Conformity levels were compared between brand-name and generic packages. A total of 124 different unit dose packages were evaluated. The level of conformity of each criterion varied between 19 and 50%. Only 43% of unit dose packages provided an easy-to-detach system for single doses. Among the 14 manufacturers with three or more unit dose packages evaluated, eight (57%) had a conformity level less than 50%. This study describes the conformity of commercial oral single solid unit dose packages in hospital pharmacy practice in Quebec. A large proportion of unit dose packages do not conform to a set of nine criteria set out in the guidelines of the American Society of Health-System Pharmacists and the Canadian Society of Hospital Pharmacists.
Is gravity a morphological determinant in plants at the cellular level
NASA Technical Reports Server (NTRS)
Krikorian, A. D.; Steward, F. C.
1978-01-01
The present paper deals with the question whether plant development can proceed normally in the weightless state, particularly in the critical stage where single cells produce multicellular units, leading to embryos with the growing regions of shoot and root which, in turn, give rise to all the tissues of the plant body. An experiment that tested whether carrot embryos capable of developing from cultured somatic cells could do so under conditions of weightlessness is described.
Molecular Recognition Directed Self-Assembly of Supramolecular Architectures
1994-06-30
TMV-Like SupraxlecuiarArchiteturc _ TMV is a simple virus consisting only of a single type of protein molecule and of a strand of ribonucleic acid (RNA...experiments have demonstrated that various substituted gallic acid derivatives can be used to construct exo-receptors with a tapered shape. 1.2...with 3,4,5-tris(p - dodecyloxybenzyloxy)benzoic acid {12-ABCr) resulted in the taper shaped structural units. 12- ABG-B1SC5 and 12-ABG-15C5
Managing the negatives of experience in physician teams.
Hoff, Timothy
2010-01-01
Experience is a key shaper of thought and action in the health care workplace and a fundamental component of management and professional policies dealing with improving quality of care. Physicians rely on experience to structure social interaction, to determine authority relations, and to resist organizational encroachments on their work and autonomy. However, an overreliance on experience within physician teams may paradoxically undermine learning, participation, and entrepreneurship, affecting organizational performance. Approximately 100 hours of direct observation of normal workdays for physician teams (n = 17 physicians) in two different work settings in a single academic medical center located in the Northeastern part of the United States. Qualitative data were collected from physician teams in the medical intensive care unit and trauma/general surgery settings. Data were transcribed and computer analyzed through an interactive process of open coding, theoretical sampling, and pattern recognition that proceeded longitudinally. Three particular experience-based schemas were identified that physician teams used to structure social relations and perform work. These schemas involved using experience as a commodity, trump card, and liberator. Each of these schemas consisted of strongly held norms, beliefs, and values that produced team dynamics with the potential for undermining learning, participation, and entrepreneurship in the group. Organizations may move to mitigate the negative impact of an overreliance on experience among physicians by promoting bureaucratic forms of control that enable physicians to engage learning, participation, and entrepreneurship in their work while not usurping existing and difficult-to-change cultural drivers of team behavior.
Information management system breadboard data acquisition and control system.
NASA Technical Reports Server (NTRS)
Mallary, W. E.
1972-01-01
Description of a breadboard configuration of an advanced information management system based on requirements for high data rates and local and centralized computation for subsystems and experiments to be housed on a space station. The system is to contain a 10-megabit-per-second digital data bus, remote terminals with preprocessor capabilities, and a central multiprocessor. A concept definition is presented for the data acquisition and control system breadboard, and a detailed account is given of the operation of the bus control unit, the bus itself, and the remote acquisition and control unit. The data bus control unit is capable of operating under control of both its own test panel and the test processor. In either mode it is capable of both single- and multiple-message operation in that it can accept a block of data requests or update commands for transmission to the remote acquisition and control unit, which in turn is capable of three levels of data-handling complexity.
Mapping the energy landscape for second-stage folding of a single membrane protein
Min, Duyoung; Jefferson, Robert E; Bowie, James U; Yoon, Tae-Young
2016-01-01
Membrane proteins are designed to fold and function in a lipid membrane, yet folding experiments within a native membrane environment are challenging to design. Here we show that single-molecule forced unfolding experiments can be adapted to study helical membrane protein folding under native-like bicelle conditions. Applying force using magnetic tweezers, we find that a transmembrane helix protein, Escherichia coli rhomboid protease GlpG, unfolds in a highly cooperative manner, largely unraveling as one physical unit in response to mechanical tension above 25 pN. Considerable hysteresis is observed, with refolding occurring only at forces below 5 pN. Characterizing the energy landscape reveals only modest thermodynamic stability (ΔG = 6.5 kBT) but a large unfolding barrier (21.3 kBT) that can maintain the protein in a folded state for long periods of time (t1/2 ~3.5 h). The observed energy landscape may have evolved to limit the existence of troublesome partially unfolded states and impart rigidity to the structure. PMID:26479439
Versatile single-chip event sequencer for atomic physics experiments
NASA Astrophysics Data System (ADS)
Eyler, Edward
2010-03-01
A very inexpensive dsPIC microcontroller with internal 32-bit counters is used to produce a flexible timing signal generator with up to 16 TTL-compatible digital outputs, with a time resolution and accuracy of 50 ns. This time resolution is easily sufficient for event sequencing in typical experiments involving cold atoms or laser spectroscopy. This single-chip device is capable of triggered operation and can also function as a sweeping delay generator. With one additional chip it can also concurrently produce accurately timed analog ramps, and another one-chip addition allows real-time control from an external computer. Compared to an FPGA-based digital pattern generator, this design is slower but simpler and more flexible, and it can be reprogrammed using ordinary `C' code without special knowledge. I will also describe the use of the same microcontroller with additional hardware to implement a digital lock-in amplifier and PID controller for laser locking, including a simple graphics-based control unit. This work is supported in part by the NSF.
NASA Astrophysics Data System (ADS)
O'Bannon, E. F., III; Vennari, C.; Beavers, C. C. G.; Williams, Q. C.
2015-12-01
Lawsonite (CaAl2Si2O7(OH)2.H2O) is a hydrous mineral with a high overall water content of ~11.5 wt.%. It is a significant carrier of water in subduction zones to depths greater than ~150 km. The structure of lawsonite has been extensively studied under room temperature, high-pressure conditions. However, simultaneous high-pressure and high-temperature experiments are scarce. We have conducted synchrotron-based simultaneous high-pressure and temperature single crystal experiments on lawsonite up to a maximum pressure of 8.4 GPa at ambient and high temperatures. We used a natural sample of lawsonite from Valley Ford, California (Sonoma County). At room pressure and temperature lawsonite crystallizes in the orthorhombic system with Cmcm symmetry. Room temperature compression indicates that lawsonite remains in the orthorhombic Cmcm space group up to ~9.0 GPa. Our 5.0 GPa crystal structure is similar to the room pressure structure, and shows almost isotropic compression of the crystallographic axes. Unit cell parameters at 5.0 GPa are a- 5.7835(10), b- 8.694(2), and c- 13.009(3). Single-crystal measurements at simultaneous high-pressure and temperature (e.g., >8.0 GPa and ~100 oC) can be indexed to a monoclinic P-centered unit cell. Interestingly, a modest temperature increase of ~100 oC appears to initiate the orthorhombic to monoclinic phase transition at ~0.6-2.4 GPa lower than room temperature compression studies have shown. There is no evidence of dehydration or H atom disorder under these conditions. This suggests that the orthorhombic to monoclinic transition could be kinetically impeded at 298 K, and that monoclinic lawsonite could be the dominant water carrier through much of the depth range of upper mantle subduction processes.
Maben, Jill; Murrells, Trevor; Griffiths, Peter
2016-01-01
Objectives A wide range of patient benefits have been attributed to single room hospital accommodation including a reduction in adverse patient safety events. However, studies have been limited to the US with limited evidence from elsewhere. The aim of this study was to assess the impact on safety outcomes of the move to a newly built all single room acute hospital. Methods A natural experiment investigating the move to 100% single room accommodation in acute assessment, surgical and older people’s wards. Move to 100% single room accommodation compared to ‘steady state’ and ‘new build’ control hospitals. Falls, pressure ulcer, medication error, meticillin-resistant Staphylococcus aureus and Clostridium difficile rates from routine data sources were measured over 36 months. Results Five of 15 time series in the wards that moved to single room accommodation revealed changes that coincided with the move to the new all single room hospital: specifically, increased fall, pressure ulcer and Clostridium difficile rates in the older people’s ward, and temporary increases in falls and medication errors in the acute assessment unit. However, because the case mix of the older people’s ward changed, and because the increase in falls and medication errors on the acute assessment ward did not last longer than six months, no clear effect of single rooms on the safety outcomes was demonstrated. There were no changes to safety events coinciding with the move at the new build control site. Conclusion For all changes in patient safety events that coincided with the move to single rooms, we found plausible alternative explanations such as case-mix change or disruption as a result of the re-organization of services after the move. The results provide no evidence of either benefit or harm from all single room accommodation in terms of safety-related outcomes, although there may be short-term risks associated with a move to single rooms. PMID:26811373
Simon, Michael; Maben, Jill; Murrells, Trevor; Griffiths, Peter
2016-07-01
A wide range of patient benefits have been attributed to single room hospital accommodation including a reduction in adverse patient safety events. However, studies have been limited to the US with limited evidence from elsewhere. The aim of this study was to assess the impact on safety outcomes of the move to a newly built all single room acute hospital. A natural experiment investigating the move to 100% single room accommodation in acute assessment, surgical and older people's wards. Move to 100% single room accommodation compared to 'steady state' and 'new build' control hospitals. Falls, pressure ulcer, medication error, meticillin-resistant Staphylococcus aureus and Clostridium difficile rates from routine data sources were measured over 36 months. Five of 15 time series in the wards that moved to single room accommodation revealed changes that coincided with the move to the new all single room hospital: specifically, increased fall, pressure ulcer and Clostridium difficile rates in the older people's ward, and temporary increases in falls and medication errors in the acute assessment unit. However, because the case mix of the older people's ward changed, and because the increase in falls and medication errors on the acute assessment ward did not last longer than six months, no clear effect of single rooms on the safety outcomes was demonstrated. There were no changes to safety events coinciding with the move at the new build control site. For all changes in patient safety events that coincided with the move to single rooms, we found plausible alternative explanations such as case-mix change or disruption as a result of the re-organization of services after the move. The results provide no evidence of either benefit or harm from all single room accommodation in terms of safety-related outcomes, although there may be short-term risks associated with a move to single rooms. © The Author(s) 2016.
Acute Respiratory Failure in Renal Transplant Recipients: A Single Intensive Care Unit Experience.
Ulas, Aydin; Kaplan, Serife; Zeyneloglu, Pinar; Torgay, Adnan; Pirat, Arash; Haberal, Mehmet
2015-11-01
Frequency of pulmonary complications after renal transplant has been reported to range from 3% to 17%. The objective of this study was to evaluate renal transplant recipients admitted to an intensive care unit to identify incidence and cause of acute respiratory failure in the postoperative period and compare clinical features and outcomes between those with and without acute respiratory failure. We retrospectively screened the data of 540 consecutive adult renal transplant recipients who received their grafts at a single transplant center and included those patients admitted to an intensive care unit during this period for this study. Acute respiratory failure was defined as severe dyspnea, respiratory distress, decreased oxygen saturation, hypoxemia or hypercapnia on room air, or requirement of noninvasive or invasive mechanical ventilation. Among the 540 adult renal transplant recipients, 55 (10.7%) were admitted to an intensive care unit, including 26 (47.3%) admitted for acute respiratory failure. Median time from transplant to intensive care unit admission was 10 months (range, 0-67 mo). The leading causes of acute respiratory failure were bacterial pneumonia (56%) and cardiogenic pulmonary edema (44%). Mean partial pressure of arterial oxygen to fractional inspired oxygen ratio was 174 ± 59, invasive mechanical ventilation was used in 13 patients (50%), and noninvasive mechanical ventilation was used in 8 patients (31%). The overall mortality was 16.4%. Acute respiratory failure was the reason for intensive care unit admission in almost half of our renal transplant recipients. Main causes of acute respiratory failure were bacterial pneumonia and cardiogenic pulmonary edema. Mortality of patients admitted for acute respiratory failure was similar to those without acute respiratory failure.
Massett, Holly A; Hampp, Sharon L; Goldberg, Jacquelyn L; Mooney, Margaret; Parreco, Linda K; Minasian, Lori; Montello, Mike; Mishkin, Grace E; Davis, Catasha; Abrams, Jeffrey S
2018-03-10
The National Institutes of Health (NIH) issued a new policy that requires a single institutional review board (IRB) of record be used for all protocols funded by the NIH that are carried out at more than one site in the United States, effective January 2018. This policy affects several hundred clinical trials opened annually across the NIH. Limited data exist to compare the use of a single IRB to that of multiple local IRBs, so some institutions are resistant to or distrustful of single IRBs. Since 2001, the National Cancer Institute (NCI) has funded a central IRB (CIRB) that provides human patient reviews for its extensive national cancer clinical trials program. This paper presents data to show the adoption, efficiencies gained, and satisfaction of the CIRB among NCI trial networks and reviews key lessons gleaned from 16 years of experience that may be informative for others charged with implementation of the new NIH single-IRB policy.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-01
... penstock intake at the powerhouse site; (2) a new powerhouse with a single turbine/generator unit at an... powerhouse site; (2) a new powerhouse with a single turbine/generator unit at an installed capacity of 0.5 MW... Franzen reservoir to the Fairmount reservoir; (2) a new powerhouse with a single turbine/ generator unit...
49 CFR 180.519 - Periodic retest and inspection of tank cars other than single-unit tank car tanks.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 2 2010-10-01 2010-10-01 false Periodic retest and inspection of tank cars other than single-unit tank car tanks. 180.519 Section 180.519 Transportation Other Regulations Relating to... of Tank Cars § 180.519 Periodic retest and inspection of tank cars other than single-unit tank car...
Nurses' autonomy in end-of-life situations in intensive care units.
Paganini, Maria Cristina; Bousso, Regina Szylit
2015-11-01
The intensive care unit environment focuses on interventions and support therapies that prolong life. The exercise by nurses of their autonomy impacts on perception of the role they assume in the multidisciplinary team and on their function in the intensive care unit context. There is much international research relating to nurses' involvement in end-of-life situations; however, there is a paucity of research in this area in Brazil. In the Brazilian medical scenario, life support limitation generated a certain reluctance of a legal nature, which has now become unjustifiable with the publication of a resolution by the Federal Medical Council. In Brazil, the lack of medical commitments to end-of-life care is evident. To understand the process by which nurses exercise autonomy in making end-of-life decisions in intensive care units. Symbolic Interactionism and Corbin and Strauss theory methodology were used for this study. Data were collected through single audio-recorded qualitative interviews with 14 critical care nurses. The comparative analysis of the data has permitted the understanding of the meaning of nurse's experience in exercising autonomy relating to end-of-life decision-making. Institutional ethics approval was obtained for data collection. Participants gave informed consent. All data were anonymized. The results revealed that nurses experience the need to exercise autonomy in intensive care units on a daily basis. Their experience expressed by the process of increase opportunities to exercise autonomy is conditioned by the pressure of the intensive care unit environment, in which nurses can grow, feel empowered, and exercise their autonomy or else can continuously depend on the decisions made by other professionals. Nurses exercise their autonomy through care. They work to create new spaces at the same time that they acquire new knowledge and make decisions. Because of the complexity of the end-of-life situation, nurses must adopt a proactive attitude that inserts them into the decision-making process. © The Author(s) 2014.
Cryogenic fluid management experiment
NASA Technical Reports Server (NTRS)
Eberhardt, R. N.; Bailey, W. J.; Fester, D. A.
1981-01-01
The cryogenic fluid management experiment (CFME), designed to characterize subcritical liquid hydrogen storage and expulsion in the low-q space environment, is discussed. The experiment utilizes a fine mesh screen fluid management device to accomplish gas-free liquid expulsion and a thermodynamic vent system to intercept heat leak and control tank pressure. The experiment design evolved from a single flight prototype to provision for a multimission (up to 7) capability. A detailed design of the CFME, a dynamic test article, and dedicated ground support equipment were generated. All materials and parts were identified, and components were selected and specifications prepared. Long lead titanium pressurant spheres and the flight tape recorder and ground reproduce unit were procured. Experiment integration with the shuttle orbiter, Spacelab, and KSC ground operations was coordinated with the appropriate NASA centers, and experiment interfaces were defined. Phase 1 ground and flight safety reviews were conducted. Costs were estimated for fabrication and assembly of the CFME, which will become the storage and supply tank for a cryogenic fluid management facility to investigate fluid management in space.
Low field domain wall dynamics in artificial spin-ice basis structure
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kwon, J.; School of Electrical and Electronic Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798; Goolaup, S.
2015-10-28
Artificial magnetic spin-ice nanostructures provide an ideal platform for the observation of magnetic monopoles. The formation of a magnetic monopole is governed by the motion of a magnetic charge carrier via the propagation of domain walls (DWs) in a lattice. To date, most experiments have been on the static visualization of DW propagation in the lattice. In this paper, we report on the low field dynamics of DW in a unit spin-ice structure measured by magnetoresistance changes. Our results show that reversible DW propagation can be initiated within the spin-ice basis. The initial magnetization configuration of the unit structure stronglymore » influences the direction of DW motion in the branches. Single or multiple domain wall nucleation can be induced in the respective branches of the unit spin ice by the direction of the applied field.« less
Serra, Jordi; Bostock, Hugh; Navarro, Xavier
2010-02-19
Microneurography is a method suitable for recording intraneural single or multiunit action potentials in conscious subjects. Microneurography has rarely been applied to animal experiments, where more invasive methods, like the teased fiber recording technique, are widely used. We have tested the feasibility of microneurographic recordings from the peripheral nerves of rats. Tungsten microelectrodes were inserted into the sciatic nerve at mid-thigh level. Single or multiunit action potentials evoked by regular electrical stimulation were recorded, digitized and displayed as a raster plot of latencies. The method allows unambiguous recording and recognition of single C-fiber action potentials from an in vivo preparation, with minimal disruption of the nerve being recorded. Multiple C-fibers can be recorded simultaneously for several hours, and if the animal is allowed to recover, repeated recording sessions can be obtained from the same nerve at the same level over a period of weeks or months. Also, single C units can be functionally identified by their changes in latency to natural stimuli, and insensitive units can be recognized as 'silent' nociceptors or sympathetic efferents by their distinctive profiles of activity-dependent slowing during repetitive electrical stimulation, or by the effect on spontaneous efferent activity of a proximal anesthetic block. Moreover, information about the biophysical properties of C axons can be obtained from their latency recovery cycles. Finally, we show that this preparation is potentially suitable for the study of C-fiber behavior in models of neuropathies and nerve lesions, both under resting conditions and in response to drug administration.
Alkaline Comet Assay for Assessing DNA Damage in Individual Cells.
Pu, Xinzhu; Wang, Zemin; Klaunig, James E
2015-08-06
Single-cell gel electrophoresis, commonly called a comet assay, is a simple and sensitive method for assessing DNA damage at the single-cell level. It is an important technique in genetic toxicological studies. The comet assay performed under alkaline conditions (pH >13) is considered the optimal version for identifying agents with genotoxic activity. The alkaline comet assay is capable of detecting DNA double-strand breaks, single-strand breaks, alkali-labile sites, DNA-DNA/DNA-protein cross-linking, and incomplete excision repair sites. The inclusion of digestion of lesion-specific DNA repair enzymes in the procedure allows the detection of various DNA base alterations, such as oxidative base damage. This unit describes alkaline comet assay procedures for assessing DNA strand breaks and oxidative base alterations. These methods can be applied in a variety of cells from in vitro and in vivo experiments, as well as human studies. Copyright © 2015 John Wiley & Sons, Inc.
Plastic Deformation of Aluminum Single Crystals at Elevated Temperatures
NASA Technical Reports Server (NTRS)
Johnson, R D; Young, A P; Schwope, A D
1956-01-01
This report describes the results of a comprehensive study of plastic deformation of aluminum single crystals over a wide range of temperatures. The results of constant-stress creep tests have been reported for the temperature range from 400 degrees to 900 degrees F. For these tests, a new capacitance-type extensometer was designed. This unit has a range of 0.30 inch over which the sensitivity is very nearly linear and can be varied from as low a sensitivity as is desired to a maximum of 20 microinches per millivolt with good stability. Experiments were carried out to investigate the effect of small amounts of prestraining, by two different methods, on the creep and tensile properties of these aluminum single crystals. From observations it has been concluded that plastic deformation takes place predominantly by slip which is accompanied by the mechanisms of kinking and polygonization.
Speed of the bacterial flagellar motor near zero load depends on the number of stator units.
Nord, Ashley L; Sowa, Yoshiyuki; Steel, Bradley C; Lo, Chien-Jung; Berry, Richard M
2017-10-31
The bacterial flagellar motor (BFM) rotates hundreds of times per second to propel bacteria driven by an electrochemical ion gradient. The motor consists of a rotor 50 nm in diameter surrounded by up to 11 ion-conducting stator units, which exchange between motors and a membrane-bound pool. Measurements of the torque-speed relationship guide the development of models of the motor mechanism. In contrast to previous reports that speed near zero torque is independent of the number of stator units, we observe multiple speeds that we attribute to different numbers of units near zero torque in both Na + - and H + -driven motors. We measure the full torque-speed relationship of one and two H + units in Escherichia coli by selecting the number of H + units and controlling the number of Na + units in hybrid motors. These experiments confirm that speed near zero torque in H + -driven motors increases with the stator number. We also measured 75 torque-speed curves for Na + -driven chimeric motors at different ion-motive force and stator number. Torque and speed were proportional to ion-motive force and number of stator units at all loads, allowing all 77 measured torque-speed curves to be collapsed onto a single curve by simple rescaling. Published under the PNAS license.
Speed of the bacterial flagellar motor near zero load depends on the number of stator units
Nord, Ashley L.; Sowa, Yoshiyuki; Steel, Bradley C.; Lo, Chien-Jung; Berry, Richard M.
2017-01-01
The bacterial flagellar motor (BFM) rotates hundreds of times per second to propel bacteria driven by an electrochemical ion gradient. The motor consists of a rotor 50 nm in diameter surrounded by up to 11 ion-conducting stator units, which exchange between motors and a membrane-bound pool. Measurements of the torque–speed relationship guide the development of models of the motor mechanism. In contrast to previous reports that speed near zero torque is independent of the number of stator units, we observe multiple speeds that we attribute to different numbers of units near zero torque in both Na+- and H+-driven motors. We measure the full torque–speed relationship of one and two H+ units in Escherichia coli by selecting the number of H+ units and controlling the number of Na+ units in hybrid motors. These experiments confirm that speed near zero torque in H+-driven motors increases with the stator number. We also measured 75 torque–speed curves for Na+-driven chimeric motors at different ion-motive force and stator number. Torque and speed were proportional to ion-motive force and number of stator units at all loads, allowing all 77 measured torque–speed curves to be collapsed onto a single curve by simple rescaling. PMID:29078322
METHODOLOGICAL NOTES: Integrating magnetism into semiconductor electronics
NASA Astrophysics Data System (ADS)
Zakharchenya, Boris P.; Korenev, Vladimir L.
2005-06-01
The view of a ferromagnetic-semiconducting hybrid structure as a single tunable system is presented. Based on an analysis of existing experiments it is shown that, contrary to a 'common sense', a nonmagnetic semiconductor is capable of playing an important role in controlling ferromagnetism. Magnetic properties of a hybrid (the hysteresis loop and the spatial orientation of magnetization) can be tuned both optically and electrically by utilizing semiconductor—making the hybrid an electronic-write-in and electronic-read-out elementary storage unit.
Command and Control Began with Subotai Bahadur, the Thirteenth Century Mongol General
2010-04-01
embodied a lifetime of Mongol military experience and training when he planned and led the Hungarian Campaign. By the time of his death in 1248 at the...to function after Chinggis Khan’s death , became the home of the best officers, and each was trained in staff work and attended education and briefin...were forbidden by punishment of death , and soldiers served their entire lives in a single unit. 57 Juvaini noted: "When the line ’goes into battle
Cygnus Orbital ATK OA-6 Liftoff
2016-03-22
At Cape Canaveral Air Force Station's Space Launch Complex 41, a United Launch Alliance Atlas V rocket with a single-engine Centaur upper stage stands ready to boost an Orbital ATK Cygnus spacecraft on a resupply mission to the International Space Station. Science payloads include the second generation of a portable onboard printer to demonstrate three-dimensional printing, an instrument for first space-based observations of the chemical composition of meteors entering Earth’s atmosphere and an experiment to study how fires burn in microgravity.
Cygnus Orbital ATK OA-6 Rollout
2016-03-21
At Cape Canaveral Air Force Station's Space Launch Complex 41, a United Launch Alliance Atlas V rocket with a single-engine Centaur upper stage stands ready to boost an Orbital ATK Cygnus spacecraft on a resupply mission to the International Space Station. Science payloads include the second generation of a portable onboard printer to demonstrate three-dimensional printing, an instrument for first space-based observations of the chemical composition of meteors entering Earth’s atmosphere and an experiment to study how fires burn in microgravity.
Litwin, S; Shahn, E; Kozinski, A W
1969-07-01
Mass distribution in a sucrose gradient of deoxyribonucleic acid (DNA) fragments arising as a result of random breaks is predicted by analytical means from which computer evaluations are plotted. The analytical results are compared with the results of verifying experiments: (i) a Monte Carlo computer experiment in which simulated molecules of DNA were individuals of unit length subjected to random "breaks" applied by a random number generator, and (ii) an in vitro experiment in which molecules of T4 DNA, highly labeled with (32)P, were stored in liquid nitrogen for variable periods of time during which a precisely known number of (32)P atoms decayed, causing single-stranded breaks. The distribution of sizes of the resulting fragments was measured in an alkaline sucrose gradient. The profiles obtained in this fashion were compared with the mathematical predictions. Both experiments agree with the analytical approach and thus permit the use of the graphs obtained from the latter as a means of determining the average number of random breaks in DNA from distributions obtained experimentally in a sucrose gradient. An example of the application of this procedure to a previously unresolved problem is provided in the case of DNA from ultraviolet-irradiated phage which undergoes a dose-dependent intracellular breakdown. The relationship between the number of lethal hits and the number of single-stranded breaks was not previously established. A comparison of the calculated number of nicks per strand of DNA with the known dose in phage-lethal hits reveals a relationship closely approximating one lethal hit to one single-stranded break.
Kinetic Characterization of Nonmuscle Myosin IIB at the Single Molecule Level*
Nagy, Attila; Takagi, Yasuharu; Billington, Neil; Sun, Sara A.; Hong, Davin K. T.; Homsher, Earl; Wang, Aibing; Sellers, James R.
2013-01-01
Nonmuscle myosin IIB (NMIIB) is a cytoplasmic myosin, which plays an important role in cell motility by maintaining cortical tension. It forms bipolar thick filaments with ∼14 myosin molecule dimers on each side of the bare zone. Our previous studies showed that the NMIIB is a moderately high duty ratio (∼20–25%) motor. The ADP release step (∼0.35 s−1) of NMIIB is only ∼3 times faster than the rate-limiting phosphate release (0.13 ± 0.01 s−1). The aim of this study was to relate the known in vitro kinetic parameters to the results of single molecule experiments and to compare the kinetic and mechanical properties of single- and double-headed myosin fragments and nonmuscle IIB thick filaments. Examination of the kinetics of NMIIB interaction with actin at the single molecule level was accomplished using total internal reflection fluorescence (TIRF) with fluorescence imaging with 1-nm accuracy (FIONA) and dual-beam optical trapping. At a physiological ATP concentration (1 mm), the rate of detachment of the single-headed and double-headed molecules was similar (∼0.4 s−1). Using optical tweezers we found that the power stroke sizes of single- and double-headed heavy meromyosin (HMM) were each ∼6 nm. No signs of processive stepping at the single molecule level were observed in the case of NMIIB-HMM in optical tweezers or TIRF/in vitro motility experiments. In contrast, robust motility of individual fluorescently labeled thick filaments of full-length NMIIB was observed on actin filaments. Our results are in good agreement with the previous steady-state and transient kinetic studies and show that the individual nonprocessive nonmuscle myosin IIB molecules form a highly processive unit when polymerized into filaments. PMID:23148220
NASA Astrophysics Data System (ADS)
Tan, Xiaodong; Xia, Nan; Young, Hunter; Richter, Claus-Peter
2015-02-01
Auditory prostheses may benefit from Infrared Neural Stimulation (INS) because optical stimulation allows for spatially selective activation of neuron populations. Selective activation of neurons in the cochlear spiral ganglion can be determined in the central nucleus of the inferior colliculus (ICC) because the tonotopic organization of frequencies in the cochlea is maintained throughout the auditory pathway. The activation profile of INS is well represented in the ICC by multichannel electrodes (MCEs). To characterize single unit properties in response to INS, however, single tungsten electrodes (STEs) should be used because of its better signal-to-noise ratio. In this study, we compared the temporal properties of ICC single units recorded with MCEs and STEs in order to characterize the response properties of single auditory neurons in response to INS in guinea pigs. The length along the cochlea stimulated with infrared radiation corresponded to a frequency range of about 0.6 octaves, similar to that recorded with STEs. The temporal properties of single units recorded with MCEs showed higher maximum rates, shorter latencies, and higher firing efficiencies compared to those recorded with STEs. When the preset amplitude threshold for triggering MCE recordings was raised to twice over the noise level, the temporal properties of the single units became similar to those obtained with STEs. Undistinguishable neural activities from multiple sources in MCE recordings could be responsible for the response property difference between MCEs and STEs. Thus, caution should be taken in single unit recordings with MCEs.
Toivonen, Mirka; Lehtonen, Liisa; Löyttyniemi, Eliisa; Axelin, Anna
Single-family rooms in neonatal intensive care unit can provide longer interaction between family and staff. On the other hand, separation in private rooms has been shown detrimental to child development if parents are not present. To examine the effects of single-family rooms on nurse-family, nurse-parent and nurse-infant interaction time in neonatal intensive care unit. A quantitative, comparative, observational study was conducted before and after a move to a neonatal intensive care unit with single-family rooms. A total of 194 observation hours were conducted before the move and 194h after the move. The differences were analyzed using a hierarchical linear mixed model. Nurses working in one neonatal intensive care unit were recruited to study. The duration and number of nurse-parent and nurse-infant interaction episodes were recorded. The nurse-family and the nurse-parent interaction were longer in the unit with single-family rooms compared with the unit before the move (mean 261 vs. 138min per shift, p<0.0001 and 117 vs. 35, p=0.001, respectively). The duration of the nurse-infant interaction did not change after the move. The frequency of the nurse-parent or the nurse-infant interactions did not change between the time periods. Neonatal intensive care unit with single-family rooms supported an increase in nurse-parent interaction time. Importantly, nurse-infant interaction time did not decrease. Copyright © 2017 Elsevier B.V. All rights reserved.
Hyperspherical von Mises-Fisher mixture (HvMF) modelling of high angular resolution diffusion MRI.
Bhalerao, Abhir; Westin, Carl-Fredrik
2007-01-01
A mapping of unit vectors onto a 5D hypersphere is used to model and partition ODFs from HARDI data. This mapping has a number of useful and interesting properties and we make a link to interpretation of the second order spherical harmonic decompositions of HARDI data. The paper presents the working theory and experiments of using a von Mises-Fisher mixture model for directional samples. The MLE of the second moment of the HvMF pdf can also be related to fractional anisotropy. We perform error analysis of the estimation scheme in single and multi-fibre regions and then show how a penalised-likelihood model selection method can be employed to differentiate single and multiple fibre regions.
Adult bone strength of children from single-parent families: the Midlife in the United States Study.
Crandall, C J; Karlamangla, A S; Merkin, S S; Binkley, N; Carr, D; Greendale, G A; Seeman, T E
2015-03-01
Bone health may be negatively impacted by childhood socio-environmental circumstances. We examined the independent associations of single-parent childhood and parental death or divorce in childhood with adult bone strength indices. Longer exposure to a single-parent household in childhood was associated with lower bone strength in adulthood. Because peak bone mass is acquired during childhood, bone health may be negatively impacted by childhood socio-environmental disadvantage. The goal of this study was to determine whether being raised in a single-parent household is associated with lower bone strength in adulthood. Using dual-energy X-ray absorptiometry data from 708 participants (mean age 57 years) in the Midlife in the United States Biomarker Project, we examined the independent associations of composite indices of femoral neck bone strength relative to load (in three failure modes: compression, bending, and impact) in adulthood with the experience of single-parent childhood and parental death or divorce in childhood. After adjustment for gender, race, menopause transition stage, age, and body mass index, each additional year of single-parent childhood was associated with 0.02 to 0.03 SD lower indices of adult femoral neck strength. In those with 9-16 years of single-parent childhood, the compression strength index was 0.41 SD lower, bending strength index was 0.31 SD lower, and impact strength index was 0.25 SD lower (all p values < 0.05). In contrast, parental death or divorce during childhood was not by itself independently associated with adult bone strength indices. The magnitudes of these associations were unaltered by additional adjustment for lifestyle factors and socioeconomic status in childhood and adulthood. Independent of parental death or divorce, growing up in a single-parent household is associated with lower femoral neck bone strength in adulthood, and this association is not entirely explained by childhood or adult socioeconomic conditions or lifestyle choices.
Mitz, Andrew R.; Chacko, Ravi V.; Putnam, Philip T.; Rudebeck, Peter H.; Murray, Elisabeth A.
2017-01-01
Background Nonhuman primates (NHPs) are a valuable research model because of their behavioral, physiological and neuroanatomical similarities to humans. In the absence of language, autonomic activity can provide crucial information about cognitive and affective states during single-unit recording, inactivation and lesion studies. Methods standardized for use in humans are not easily adapted to NHPs and detailed guidance has been lacking. New Method We provide guidance for monitoring heart rate and pupil size in the behavioral neurophysiology setting by addressing the methodological issues, pitfalls and solutions for NHP studies. The methods are based on comparative physiology to establish a rationale for each solution. We include examples from both electrophysiological and lesion studies. Results Single-unit recording, pupil responses and heart rate changes represent a range of decreasing temporal resolution, a characteristic that impacts experimental design and analysis. We demonstrate the unexpected result that autonomic measures acquired before and after amygdala lesions are comparable despite disruption of normal autonomic function. Comparison with Existing Methods Species and study design differences can render standard techniques used in human studies inappropriate for NHP studies. We show how to manage data from small groups typical of NHP studies, data from the short behavioral trials typical of neurophysiological studies, issues associated with longitudinal studies, and differences in anatomy and physiology. Conclusions Autonomic measurement to infer cognitive and affective states in NHP is neither off-the-shelf nor onerous. Familiarity with the issues and solutions will broaden the use of autonomic signals in NHP single unit and lesion studies. PMID:28089759
24 CFR 3280.802 - Definitions.
Code of Federal Regulations, 2014 CFR
2014-04-01
... panelboard means a single panel or a group of panel units designed for assembly in the form of a single panel... control of light, heat, or power circuits of small individual as well as aggregate capacity; designed to...) Panelboard means a single panel or group of panel units designed for assembly in the form of a single panel...
Peritonitis: 10 years' experience in a single surgical unit.
Agarwal, Nitin; Saha, Sudipta; Srivastava, Anurag; Chumber, Sunil; Dhar, Anita; Garg, Sanket
2007-01-01
Peritonitis secondary to gut perforation is still one of the commonest surgical emergencies in India and is associated with high morbidity and mortality. The present study examines the aetiology and outcome of peritonitis cases operated on in our surgical unit, and compares our findings with those of previous studies performed between 1981 and 1991. A retrospective study of 260 peritonitis patients operated on in a single surgical unit from 1995 to 2006 was done and data involving clinical presentation, operative findings and post-operative course were studied and analysed. Causes of peritonitis were small bowel perforation (96 ileal, 17 jejunal), peptic perforation (45 duodenal, 16 gastric), appendicular perforation (36), primary peritonitis (8), and others (42). The incidence of major complications was 25% (burst-11%, leak-5%, intraabdominal abscess-5%, multi-organ failure-6.5%). The overall mortality was 10%. High mortality was observed in jejunal, gall bladder and liver abscess perforation cases (> 20%). Histopathological evaluation (143 specimens) revealed tuberculosis in 42 (mostly small bowel), malignancy in 8, and inflammation in the rest. Comparisons with a similar study carried out in the same unit and published in 1995 revealed similar demographic features and mortality, but a change in the most common cause (peptic ulcer perforation to small bowel perforation), and an increased performance of enterostomy compared with primary repair in small bowel perforation and a decrease in the leak rate (13% to 4%). Small bowel perforation is the commonest form of perforation and the mortality rate associated with peritonitis remains unchanged.
NASA Astrophysics Data System (ADS)
Chen, Haidong; Che, Wenquan; Zhang, Tianyu; Cao, Yue; Feng, Wenjie
2018-06-01
Half-mode substrate integrated waveguide (HMSIW) switchable unit, built by HMSIW section with loaded single or multi-microstrip shunt stub(s), was proposed in this work. Both shorted and opened stubs were studied, investigated and compared, bandwidth enhancement method for proposed switchable units was proposed and demonstrated. Based on these switchable units, narrowband and broadband HMSIW single-pole-single-through (SPST) switches, SIW SPST switch and SIW/HMSIW-based single-pole-double-through (SPDT) switch were designed, fabricated and measured. Good performances were observed experimentally for these proposed circuits, showing the advantages of proposed concept and an excellent candidate for switchable or reconfigurable SIW/HMSIW circuits or systems.
Whiting, I M; Pirgozliev, V; Rose, S P; Wilson, J; Amerah, A M; Ivanova, S G; Staykova, G P; Oluwatosin, O O; Oso, A O
2017-03-01
Wheat distillers' dried grains with solubles (DDGS) are being used increasingly in the poultry feed industry but their nutritional value is variable. The aim of this experiment was to examine the effect of batch to batch variation of wheat DDGS produced by the same manufacturer on the growth performance, dietary N corrected apparent metabolizable energy (AMEn), energy conversion ratio (ECR), total tract dry matter retention (DMR), nitrogen retention (NR) and fat digestibility (FD) coefficients when fed to broilers in complete diets with and without enzyme supplementation. Six UK wheat DDGS samples, produced by a single manufacturer, were used in a broiler experiment. Six diets containing 150 g/kg of each selected wheat DDGS sample were mixed. Each diet was then split into two batches and one of them was supplemented with commercial enzyme preparation, providing 1220 units xylanase and 152 units of β-glucanase/kg diet, resulting in 12 experimental diets. Each diet was fed ad libitum to five pens of two male Ross 308 broilers from 7 to 21 d old. Enzyme supplementation improved dietary AMEn, DMR, NR (P < 0.001) and FD (P < 0.05) compared to non-supplemented diets. There was DDGS sample by enzyme interaction (P < 0.05) on daily weight gain and ECR. The results suggest that the variability in AMEn of DDGS samples produced from a single manufacturer is greater than expected compared to the variability of whole wheat samples but substantially lower than expected from wheat DDGS samples from different EU manufacturers. This experiment has shown that the variation in feeding value of wheat DDGS may be explained by the variability in polysaccharide contents. © 2016 Poultry Science Association Inc.
The Tri-lab Tantalum Strength Consortium
NASA Astrophysics Data System (ADS)
Flicker, Dawn G.; Arsenlis, Thomas A.; Austin, Ryan; Barton, Nathan R.; Benage, John F.; Bronkhorst, Curt A.; Brown, Justin L.; Brown, Staci L.; Buttler, William T.; Shen, Shuh-Rong; Dattelbaum, Dana M.; Fensin, Sayu J.; Gray, George T., III; Lane, J. Matthew D.; Lim, Hojun; Luscher, D. J.; Mattsson, Thomas R.; McNabb, Dennis P.; Remington, Bruce A.; Park, Hye-Sook; Prisbrey, Shon T.; Prime, Michael B.; Scharff, Robert J.; Schraad, Mark W.; Sun, Amy C.
2017-06-01
A Tri-lab consortium of experimentalists and theorists at SNL, LLNL, and LANL is joining forces to better understand tantalum strength across an unprecedented range of loading conditions. The team is collecting and comparing tantalum strength data from Hopkinson bar, Taylor cylinder, guns, Z, Omega and the NIF. These experiments, all using Ta from a single lot, span pressures from tenths to hundreds of GPa and strain rates from 103 to 107. New experiments are underway to provide more overlap between the platforms. The experiments are being simulated with a variety of models in order to determine which processes are important under which conditions. The presentation will show results to date. Sandia is a multi-program laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy under contract DE-AC04-94AL85000.
Effect of Soybean Casein Digest Agar Lot on Number of Bacillus stearothermophilus Spores Recovered †
Pflug, I. J.; Smith, Geraldine M.; Christensen, Ronald
1981-01-01
In recent years it has become increasingly apparent that Bacillus stearothermophilus spores are affected by various environmental factors that influence the performance of the spores as biological indicators. One environmental factor is the recovery medium. The effect of different lots of commercial soybean casein digest agar on the number of colony-forming units per plate was examined in two series of experiments: (i) several lots of medium from two manufacturers were compared in single experiments, and (ii) paired media experiments with four lots of medium were carried out and yielded three-point survivor curves. The results demonstrate that commercial soybean casein digest agar is variable on a lot-to-lot basis. The variation was lowest when recovering unheated or minimally heated spores and increased greatly with the severity of heating. PMID:16345822
One-Unit versus Two-Unit Cord-Blood Transplantation for Hematologic Cancers
Wagner, John E.; Eapen, Mary; Carter, Shelly; Wang, Yanli; Schultz, Kirk R.; Wall, Donna A.; Bunin, Nancy; Delaney, Colleen; Haut, Paul; Margolis, David; Peres, Edward; Verneris, Michael R.; Walters, Mark; Horowitz, Mary M.; Kurtzberg, Joanne
2014-01-01
BACKGROUND Umbilical-cord blood has been used as the source of hematopoietic stem cells in an estimated 30,000 transplants. The limited number of hematopoietic cells in a single cord-blood unit prevents its use in recipients with larger body mass and results in delayed hematopoietic recovery and higher mortality. Therefore, we hypothesized that the greater numbers of hematopoietic cells in two units of cord blood would be associated with improved outcomes after transplantation. METHODS Between December 1, 2006, and February 24, 2012, a total of 224 patients 1 to 21 years of age with hematologic cancer were randomly assigned to undergo double-unit (111 patients) or single-unit (113 patients) cord-blood transplantation after a uniform myeloablative conditioning regimen and immunoprophylaxis for graft-versus-host disease (GVHD). The primary end point was 1-year overall survival. RESULTS Treatment groups were matched for age, sex, self-reported race (white vs. nonwhite), performance status, degree of donor–recipient HLA matching, and disease type and status at transplantation. The 1-year overall survival rate was 65% (95% confidence interval [CI], 56 to 74) and 73% (95% CI, 63 to 80) among recipients of double and single cord-blood units, respectively (P = 0.17). Similar outcomes in the two groups were also observed with respect to the rates of disease-free survival, neutrophil recovery, transplantation-related death, relapse, infections, immunologic reconstitution, and grade II–IV acute GVHD. However, improved platelet recovery and lower incidences of grade III and IV acute and extensive chronic GVHD were observed among recipients of a single cord-blood unit. CONCLUSIONS We found that among children and adolescents with hematologic cancer, survival rates were similar after single-unit and double-unit cord-blood transplantation; however, a single-unit cord-blood transplant was associated with better platelet recovery and a lower risk of GVHD. PMID:25354103
One-unit versus two-unit cord-blood transplantation for hematologic cancers.
Wagner, John E; Eapen, Mary; Carter, Shelly; Wang, Yanli; Schultz, Kirk R; Wall, Donna A; Bunin, Nancy; Delaney, Colleen; Haut, Paul; Margolis, David; Peres, Edward; Verneris, Michael R; Walters, Mark; Horowitz, Mary M; Kurtzberg, Joanne
2014-10-30
Umbilical-cord blood has been used as the source of hematopoietic stem cells in an estimated 30,000 transplants. The limited number of hematopoietic cells in a single cord-blood unit prevents its use in recipients with larger body mass and results in delayed hematopoietic recovery and higher mortality. Therefore, we hypothesized that the greater numbers of hematopoietic cells in two units of cord blood would be associated with improved outcomes after transplantation. Between December 1, 2006, and February 24, 2012, a total of 224 patients 1 to 21 years of age with hematologic cancer were randomly assigned to undergo double-unit (111 patients) or single-unit (113 patients) cord-blood transplantation after a uniform myeloablative conditioning regimen and immunoprophylaxis for graft-versus-host disease (GVHD). The primary end point was 1-year overall survival. Treatment groups were matched for age, sex, self-reported race (white vs. nonwhite), performance status, degree of donor-recipient HLA matching, and disease type and status at transplantation. The 1-year overall survival rate was 65% (95% confidence interval [CI], 56 to 74) and 73% (95% CI, 63 to 80) among recipients of double and single cord-blood units, respectively (P=0.17). Similar outcomes in the two groups were also observed with respect to the rates of disease-free survival, neutrophil recovery, transplantation-related death, relapse, infections, immunologic reconstitution, and grade II-IV acute GVHD. However, improved platelet recovery and lower incidences of grade III and IV acute and extensive chronic GVHD were observed among recipients of a single cord-blood unit. We found that among children and adolescents with hematologic cancer, survival rates were similar after single-unit and double-unit cord-blood transplantation; however, a single-unit cord-blood transplant was associated with better platelet recovery and a lower risk of GVHD. (Funded by the National Heart, Lung, and Blood Institute and the National Cancer Institute; ClinicalTrials.gov number, NCT00412360.).
NASA Astrophysics Data System (ADS)
Dudka, A. P.; Antipin, A. M.; Verin, I. A.
2017-09-01
Huber-5042 diffractometer with a closed-cycle Displex DE-202 helium cryostat is a unique scientific instrument for carrying out X-ray diffraction experiments when studying the single crystal structure in the temperature range of 20-300 K. To make the service life longer and develop new experimental techniques, the diffractometer control is transferred to a new hardware and software platform. To this end, a modern computer; a new detector reader unit; and new control interfaces for stepper motors, temperature controller, and cryostat vacuum pumping system are used. The system for cooling the X-ray tube, the high-voltage generator, and the helium compressor and pump for maintaining the desired vacuum in the cryostat are replaced. The system for controlling the primary beam shutter is upgraded. A biological shielding is installed. The new program tools, which use the Linux Ubuntu operating system and SPEC constructor, include a set of drivers for control units through the aforementioned interfaces. A program for searching reflections from a sample using fast continuous scanning and a priori information about crystal is written. Thus, the software package for carrying out the complete cycle of precise diffraction experiment (from determining the crystal unit cell to calculating the integral reflection intensities) is upgraded. High quality of the experimental data obtained on this equipment is confirmed in a number of studies in the temperature range from 20 to 300 K.
Modelling of sequential groundwater treatment with zero valent iron and granular activated carbon.
Bayer, Peter; Finkel, Michael
2005-06-01
Multiple contaminant mixtures in groundwater may not efficiently be treated by a single technology if contaminants possess rather different properties with respect to sorptivity, solubility, and degradation potential. An obvious choice is to use sequenced units of the generally accepted treatment materials zero valent iron (ZVI) and granular activated carbon (GAC). However, as the results of this modelling study suggest, the required dimensions of both reactor units may strongly differ from those expected on the grounds of a contaminant-specific design. This is revealed by performing an analysis for a broad spectrum of design alternatives through numerical experiments for selected patterns of contaminant mixtures consisting of monochlorobenzene, tetrachloroethylene, trichloroethylene (TCE), cis-1,2-dichloroethylene (cis-DCE), and vinyl chloride (VC). It is shown that efficient treatment can be achieved only if competitive sorption effects in the GAC unit as well as the formation of intermediate products in the ZVI unit are carefully taken into account. Cost-optimal designs turned out to vary extremely depending on the prevailing conditions concerning contaminant concentrations, branching ratios, and unit costs of both reactor materials. Where VC is the critical contaminant, due to high initial concentration or extensive production as an intermediate, two options are cost-effective: an oversized ZVI unit with an oversized GAC unit or a pure GAC reactor.
Solid oxide fuel cell with multi-unit construction and prismatic design
McPheeters, Charles C.; Dees, Dennis W.; Myles, Kevin M.
1999-01-01
A single cell unit of a solid oxide fuel cell that is individually fabricated and sintered prior to being connected to adjacent cells to form a solid oxide fuel cell. The single cell unit is comprised of a shaped anode sheet positioned between a flat anode sheet and an anode-electrolyte-cathode (A/E/C) sheet, and a shaped cathode sheet positioned between the A/E/C sheet and a cathode-interconnect-anode (C/I/A) sheet. An alternate embodiment comprises a shaped cathode sheet positioned between an A/E/C sheet and a C/I/A sheet. The shaped sheets form channels for conducting reactant gases. Each single cell unit is individually sintered to form a finished sub-assembly. The finished sub-assemblies are connected in electrical series by interposing connective material between the end surfaces of adjacent cells, whereby individual cells may be inspected for defects and interchanged with non-defective single cell units.
NASA Astrophysics Data System (ADS)
Maury, P.; Calamy, H.; Grunenwald, J.; Lassalle, F.; Zucchini, F.; Loyen, A.; Georges, A.; Morell, A.; Bedoch, J. P.
2009-01-01
The Sphinx machine[1] is a 6 MA, 1 μS driver based on the LTD technology, used for Z-pinch experiments. Important improvements of Sphinx radiation output were recently obtained using a multi-microsecond current prepulse[2]. Total power per unit of length is multiplied by a factor of 6 and FWHM divided by a factor of 2.5. Early breakdown of the wires during the prepulse phase dramatically changes the ablation phase leading to an improvement of axial homogeneity of both the implosion and the final radiating column. As a consequence, the cathode bubble observed on classical shots is definitively removed. The implosion is then centered and zippering effect is reduced, leading to simultaneous x-ray emission of the whole length. A great reproducibility is obtained. Nested arrays were used before to mitigate the Rayleigh-Taylor instabilities during the implosion phase. Further experiments with pre-pulse technique are described here were inner array was removed. The goal of these experiments was to see if long prepulse could give stable enough implosion with single array and at the same time increase the η parameter by reducing the mass of the load. Experimental results of single wire array loads of typical dimension 5 cm in height with implosion time between 700 and 900 ns and diameter varying between 80 and 140 mm are given. Parameters of the loads were varying in term of radius and number of wires. Comparisons with nested wire array loads are done and trends are proposed. Characteristics of both the implosion and the final radiating column are shown. 2D MHD numerical simulations of single wire array become easier as there is no interaction between outer and inner array anymore. A systematic study was done using injection mass model to benchmark simulation with experiments.
Management of cystinuric patients: an observational, retrospective, single-centre analysis.
Ahmed, Kamran; Khan, Mohammad Shamim; Thomas, Kay; Challacombe, Ben; Bultitude, Matthew; Glass, Jonathan; Tiptaft, Richard; Dasgupta, Prokar
2008-01-01
A critical appraisal of the management of patients with cystine stones treated in our unit in the past 6 years and to analyze the outcome of multimodality therapies. An observational, single-centre retrospective study. We reviewed the records of all patients with stones referred to our centre over a 6-year period from 1998 to 2005. Data recorded included demographic details, medical therapies received/prescribed, compliance with medical therapies, mode of treatment, stone clearance and any recurrence during this period of study. A total of 30 cystinuric patients were treated in our institution over the period of 6 years from 1998 to early 2005. Of these 16 were males and 14 females with an average age at last follow-up of 39 years (range 15-70). Two patients were successfully managed medically. The remaining patients (n = 28) underwent a total of 237 procedures (pre- and postreferral to our unit), with an average of 7.9 procedures per patient for 126 stone episodes (4.2 episodes/patient). The modes of treatment included extracorporeal shockwave lithotripsy (n = 143), ureterorenoscopy and intracorporeal lithotripsy (n = 50), percutaneous nephrolithotomy (n = 28) and open procedures (n = 16). Two patients needed open surgery at our unit. Prior to referral to our dedicated unit, patients had received treatment with extracorporeal shockwave lithotripsy (multiple sessions), ureteroscopy (n = 14), percutaneous nephrolithotomy (n = 4) and open stone removal (n = 14). Most of the stones at our unit were managed using minimally invasive therapies. Compliance of cystinuric patients with medical treatment is often poor and patients experience recurrent stone episodes requiring multiple interventions. Modern management of cystine calculi should be with staged minimally invasive procedures to avoid the complications of multiple open procedures wherever possible along with appropriate medical prophylaxis.
Hydroxyapatite ceramic implants for cranioplasty in children: a single-center experience.
Zaccaria, Laura; Tharakan, Sasha Job; Altermatt, Stefan
2017-02-01
The use of hydroxyapatite ceramic (HAC) implants for the treatment of skull defects in pediatric patients started 2010 at our institution. Ceramic implants facilitate osteoblast migration and therefore optimize osteointegration with the host bone. The purpose of this study is to report a single-center experience with this treatment modality. A retrospective review of all patients from July 2010 through June 2014 undergoing a cranioplasty using hydroxyapatite ceramic implant and managed at a single institution was performed. Indication for cranioplasty, the hospital course, and follow-up were reviewed. Bone density was measured in Hounsfield Units (HU) and osteointegration was calculated using Mimics Software® (Mimics Innovation Suite v17.0 Medical, Materialize, Leuven, Belgium). Over the 4-year period, six patients met criteria for the study. Five patients had an osteointegration of nearly 100%. One patient had an incomplete osteointegration with a total bone-implant contact area of 69%. The mean bone density was 2800 HU (2300-3000 HU). Bone density alone is estimated to have a Hounsfield value between 400 and 2000 HU depending on the body region and bone quality. There were no major complications, and the patients were highly satisfied with the esthetical result. Hydroxyapatite ceramic implants for cranioplasty in pediatric patients are a good choice for different indications. The implants show excellent osteointegration and esthetical results.
NASA Technical Reports Server (NTRS)
Bush, W. H.
1974-01-01
The Skylab food program was a major effort involving a complex spectrum of activities necessary for the preparation of a crew feeding system. Approximately 17,000 individual food packages and support items, weighing more than 1225 kg, were launched into space as a single unit on board the orbital workshop. This unit provided the three (three-man) Skylab crews with nourishing foods and beverages for a total of 156 days, as well as with eating utensils and accessory items. Additionally, provisions for 5 days (15 man-days) were provided in each of the three command and service modules in a manner similar to that of the Apollo flights. The Skylab food system not only provided the crew with a palatable balanced diet in a familiar and acceptable manner but also supported the formidable mineral balance medical experiment series (M070).
Chen, Chen; Zhang, Chongfu; Liu, Deming; Qiu, Kun; Liu, Shuang
2012-10-01
We propose and experimentally demonstrate a multiuser orthogonal frequency-division multiple access passive optical network (OFDMA-PON) with source-free optical network units (ONUs), enabled by tunable optical frequency comb generation technology. By cascading a phase modulator (PM) and an intensity modulator and dynamically controlling the peak-to-peak voltage of a PM driven signal, a tunable optical frequency comb source can be generated. It is utilized to assist the configuration of a multiple source-free ONUs enhanced OFDMA-PON where simultaneous and interference-free multiuser upstream transmission over a single wavelength can be efficiently supported. The proposed multiuser OFDMA-PON is scalable and cost effective, and its feasibility is successfully verified by experiment.
Morris, Heather C; Damon, Michael; Maule, Jake; Monaco, Lisa A; Wainwright, Norm
2012-09-01
Abstract A portable, rapid, microbial detection unit, the Lab-On-a-Chip Application Development Portable Test System (LOCAD-PTS), was launched to the International Space Station (ISS) as a technology demonstration unit in December 2006. Results from the first series of experiments designed to detect Gram-negative bacteria on ISS surfaces by quantifying a single microbial biomarker lipopolysaccharide (LPS) were reported in a previous article. Herein, we report additional technology demonstration experiments expanding the on-orbit capabilities of the LOCAD-PTS to detecting three different microbial biomarkers on ISS surfaces. Six different astronauts on more than 20 occasions participated in these experiments, which were designed to test the new beta-glucan (fungal cell wall molecule) and lipoteichoic acid (LTA; Gram-positive bacterial cell wall component) cartridges individually and in tandem with the existing Limulus Amebocyte Lysate (LAL; Gram-negative bacterial LPS detection) cartridges. Additionally, we conducted the sampling side by side with the standard culture-based detection method currently used on the ISS. Therefore, we present data on the distribution of three microbial biomarkers collected from various surfaces in every module present on the ISS at the time of sampling. In accordance with our previous experiments, we determined that spacecraft surfaces known to be frequently in contact with crew members demonstrated higher values of all three microbial molecules. Key Words: Planetary protection-Spaceflight-Microbiology-Biosensor. Astrobiology 12, 830-840.
24 CFR 3280.802 - Definitions.
Code of Federal Regulations, 2012 CFR
2012-04-01
... supply. (15) Distribution panelboard means a single panel or a group of panel units designed for assembly...) Panelboard means a single panel or group of panel units designed for assembly in the form of a single panel... treatment of air so as to control simultaneously its temperature, humidity, cleanliness, and distribution to...
Adhesion energy of single wall carbon nanotube loops on various substrates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Tianjun; Department of Physics, Shaoxing University, 508 Huancheng West Rd., Shaoxing 312000; Ayari, Anthony
2015-04-28
The physics of adhesion of one-dimensional nano structures such as nanotubes, nano wires, and biopolymers on different substrates is of great interest for the study of biological adhesion and the development of nano electronics and nano mechanics. In this paper, we present force spectroscopy experiments of individual single wall carbon nanotube loops using a home-made interferometric atomic force microscope. Characteristic force plateaus during the peeling process allow the quantitative measurement of the adhesion energy per unit length on various substrates: graphite, mica, platinum, gold, and silicon. Moreover, using a time-frequency analysis of the deflection of the cantilever, we estimate themore » dynamic stiffness of the contact, providing more information on the nanotube configurations and its intrinsic mechanical properties.« less
A sEMG model with experimentally based simulation parameters.
Wheeler, Katherine A; Shimada, Hiroshima; Kumar, Dinesh K; Arjunan, Sridhar P
2010-01-01
A differential, time-invariant, surface electromyogram (sEMG) model has been implemented. While it is based on existing EMG models, the novelty of this implementation is that it assigns more accurate distributions of variables to create realistic motor unit (MU) characteristics. Variables such as muscle fibre conduction velocity, jitter (the change in the interpulse interval between subsequent action potential firings) and motor unit size have been considered to follow normal distributions about an experimentally obtained mean. In addition, motor unit firing frequencies have been considered to have non-linear and type based distributions that are in accordance with experimental results. Motor unit recruitment thresholds have been considered to be related to the MU type. The model has been used to simulate single channel differential sEMG signals from voluntary, isometric contractions of the biceps brachii muscle. The model has been experimentally verified by conducting experiments on three subjects. Comparison between simulated signals and experimental recordings shows that the Root Mean Square (RMS) increases linearly with force in both cases. The simulated signals also show similar values and rates of change of RMS to the experimental signals.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Hongwei; Cao, Ranran; Yu, Shixin
Single-layer catalysis sparks huge interests and gains widespread attention owing to its high activity. Simultaneously, three-dimensional (3D) hierarchical structure can afford large surface area and abundant reactive sites, contributing to high efficiency. Herein, we report an absorbing single-unit-cell layer established Bi2WO6 3D hierarchical architecture fabricated by a sodium dodecyl benzene sulfonate (SDBS)-assisted assembled strategy. The DBS- long chains can adsorb on the (Bi2O2)2+ layers and hence impede stacking of the layers, resulting in the single-unit-cell layer. We also uncovered that SDS with a shorter chain is less effective than SDBS. Due to the sufficient exposure of surface O atoms, single-unit-cellmore » layer 3D Bi2WO6 shows strong selectivity for adsorption on multiform organic dyes with different charges. Remarkably, the single-unit-cell layer 3D Bi2WO6 casts profoundly enhanced photodegradation activity and especially a superior photocatalytic H2 evolution rate, which is 14-fold increase in contrast to the bulk Bi2WO6. Systematic photoelectrochemical characterizations disclose that the substantially elevated carrier density and charge separation efficiency take responsibility for the strengthened photocatalytic performance. Additionally, the possibility of single-unit-cell layer 3D Bi2WO6 as dye-sensitized solar cells (DSSC) has also been attempted and it was manifested to be a promising dye-sensitized photoanode for oxygen evolution reaction (ORR). Our work not only furnish an insight into designing single-layer assembled 3D hierarchical architecture, but also offer a multi-functional material for environmental and energy applications.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, H.; Higuchi, T.; Nishioki, N.
1997-01-01
A dual tunneling-unit scanning tunneling microscope (DTU STM) was developed for nm order length measurement with wide scan range. The crystalline lattice of highly oriented pyrolitic graphite (HOPG) was used as reference scale. A reference unit was set up on top of a test unit. The reference sample holder and the probe tip of test unit were attached to one single XY scanner on either surface, while the test sample holder was open. This enables simultaneous acquisition of wide images of HOPG and test sample. The length in test sample image was measured by counting the number of HOPG lattices.more » An inchworm actuator and an impact drive mechanism were introduced to roughly position probe tips. The XY scanner was designed to be elastic to eliminate image distortion. Some comparison experiments using two HOPG chips were carried out in air. The DTU STM is confirmed to be a stable and more powerful device for length measurement which has nanometer accuracy when covering a wide scan range up to several micrometers, and is capable of measuring comparatively large and heavy samples. {copyright} {ital 1997 American Vacuum Society.}« less
NASA Astrophysics Data System (ADS)
Bruns, Tim M.; Gaunt, Robert A.; Weber, Douglas J.
2011-10-01
The development of bladder and bowel neuroprostheses may benefit from the use of sensory feedback. We evaluated the use of high-density penetrating microelectrode arrays in sacral dorsal root ganglia (DRG) for recording bladder and perineal afferent activity. Arrays were inserted in S1 and S2 DRG in three anesthetized cats. Neural signals were recorded while the bladder volume was modulated and mechanical stimuli were applied to the perineal region. In two experiments, 48 units were observed that tracked bladder pressure with their firing rates (79% from S2). At least 50 additional units in each of the three experiments (274 total; 60% from S2) had a significant change in their firing rates during one or more perineal stimulation trials. This study shows the feasibility of obtaining bladder-state information and other feedback signals from the pelvic region with a sacral DRG electrode interface located in a single level. This natural source of feedback would be valuable for providing closed-loop control of bladder or other pelvic neuroprostheses.
Single neuronal recordings using surface micromachined polysilicon microelectrodes.
Muthuswamy, Jit; Okandan, Murat; Jackson, Nathan
2005-03-15
Bulk micromachining techniques of silicon have been used successfully in the past several years to microfabricate microelectrodes for monitoring single neurons in acute and chronic experiments. In this study we report for the first time a novel surface micromachining technique to microfabricate a very thin polysilicon microelectrode that can be used for monitoring single-unit activity in the central nervous system. The microelectrodes are 3 mm long and 50 microm x 3.75 microm in cross-section. Excellent signal to noise ratios in the order of 25-35 dB were obtained while recording neuronal action potentials. The microelectrodes successfully penetrated the brains after a microincision of the dura mater. Chronic implantation of the microprobe for up to 33 days produced only minor gliosis. Since the polysilicon shank acts as a conductor, additional processing steps involved in laying conductor lines on silicon substrates are avoided. Further, surface micromachining allows for fabricating extremely thin microelectrodes which could result in decreased inflammatory responses. We conclude that the polysilicon microelectrode reported here could be a complementary approach to bulk-micromachined silicon microelectrodes for chronic monitoring of single neurons in the central nervous system.
Janoschka, Tobias; Friebe, Christian; Hager, Martin D; Martin, Norbert; Schubert, Ulrich S
2017-04-01
By combining a viologen unit and a 2,2,6,6-tetramethylpiperidin-1-oxyl (TEMPO) radical in one single combi-molecule, an artificial bipolar redox-active material, 1-(4-(((1-oxyl-2,2,6,6-tetramethylpiperidin-4-yl)oxy)carbonyl)benzyl)-1'-methyl-[4,4'-bipyridine]-1,1'-diium-chloride ( VIOTEMP ), was created that can serve as both the anode (-0.49 V) and cathode (0.67 V vs. Ag/AgCl) in a water-based redox-flow battery. While it mimics the redox states of flow battery metals like vanadium, the novel aqueous electrolyte does not require strongly acidic media and is best operated at pH 4. The electrochemical properties of VIOTEMP were investigated by using cyclic voltammetry, rotating disc electrode experiments, and spectroelectrochemical methods. A redox-flow battery was built and the suitability of the material for both electrodes was demonstrated through a polarity-inversion experiment. Thus, an organic aqueous electrolyte system being safe in case of cross contamination is presented.
Single-pixel non-imaging object recognition by means of Fourier spectrum acquisition
NASA Astrophysics Data System (ADS)
Chen, Huichao; Shi, Jianhong; Liu, Xialin; Niu, Zhouzhou; Zeng, Guihua
2018-04-01
Single-pixel imaging has emerged over recent years as a novel imaging technique, which has significant application prospects. In this paper, we propose and experimentally demonstrate a scheme that can achieve single-pixel non-imaging object recognition by acquiring the Fourier spectrum. In an experiment, a four-step phase-shifting sinusoid illumination light is used to irradiate the object image, the value of the light intensity is measured with a single-pixel detection unit, and the Fourier coefficients of the object image are obtained by a differential measurement. The Fourier coefficients are first cast into binary numbers to obtain the hash value. We propose a new method of perceptual hashing algorithm, which is combined with a discrete Fourier transform to calculate the hash value. The hash distance is obtained by calculating the difference of the hash value between the object image and the contrast images. By setting an appropriate threshold, the object image can be quickly and accurately recognized. The proposed scheme realizes single-pixel non-imaging perceptual hashing object recognition by using fewer measurements. Our result might open a new path for realizing object recognition with non-imaging.
2009-01-01
CPCO Centre de Planification et de Conduite des Opérations CPF Centre de Préparation des Forces CPX command post exercise CT collective training CTC...forces presides over the joint staff and commands French forces in the conduct of operations through the Centre de Planification et de Conduite des...i] t is difficult to identify a single concise statement of the government’s foreign policy.”17 The committee instead pointed to the mission state
Three-unit bridge construction in anterior single-pontic areas using a metal-free restorative.
Narcisi, E M
1999-02-01
A new glass-ceramic material, IPS Empress 2, is revolutionizing esthetic restorative dentistry by allowing metal-free, three-unit bridge construction in anterior and premolar single-pontic areas. The case discussed in this article illustrates the material's application in the dual-arch restoration of a young woman with congenitally missing teeth. The material was used as an alternative to single-tooth implant restorations to place two maxillary three-unit bridges, one mandibular three-unit bridge, and two mandibular porcelain veneers. IPS Empress 2 provides an esthetic alternative to porcelain-fused-to-metal restorations by facilitating attractive, functional tooth restoration.
NASA Astrophysics Data System (ADS)
Ren, Jianhua; Tian, Yuan; Hossain, Ekram; Connolly, Michael D.
2016-04-01
Peptoids are peptide-mimicking oligomers consisting of N-alkylated glycine units. The fragmentation patterns for six singly and doubly protonated model peptoids were studied via collision-induced dissociation tandem mass spectrometry. The experiments were carried out on a triple quadrupole mass spectrometer with an electrospray ionization source. Both singly and doubly protonated peptoids were found to fragment mainly at the backbone amide bonds to produce peptoid B-type N-terminal fragment ions and Y-type C-terminal fragment ions. However, the relative abundances of B- versus Y-ions were significantly different. The singly protonated peptoids fragmented by producing highly abundant Y-ions and lesser abundant B-ions. The Y-ion formation mechanism was studied through calculating the energetics of truncated peptoid fragment ions using density functional theory and by controlled experiments. The results indicated that Y-ions were likely formed by transferring a proton from the C-H bond of the N-terminal fragments to the secondary amine of the C-terminal fragments. This proton transfer is energetically favored, and is in accord with the observation of abundant Y-ions. The calculations also indicated that doubly protonated peptoids would fragment at an amide bond close to the N-terminus to yield a high abundance of low-mass B-ions and high-mass Y-ions. The results of this study provide further understanding of the mechanisms of peptoid fragmentation and, therefore, are a valuable guide for de novo sequencing of peptoid libraries synthesized via combinatorial chemistry.
Gravvanis, Andreas; Smith, Roger W
2010-10-01
The esthetic outcome is dictated essentially not only by the position, size, and shape of the reconstructed breast, but also by the extra scaring involved. In the present study, we conducted a visual analog scale survey to compare the esthetic outcome in delayed autologous breast reconstruction following two different abdominal flaps inset. Twenty-five patients had their reconstruction using the Single-esthetic Unit principle and were compared with 25 patients that their breast was reconstructed using the Two-Esthetic Unit principle. Photographic images were formulated to a PowerPoint presentation and cosmetic outcomes were assessed from 30 physicians, by means of a Questionnaire and a visual analog scale. Our data showed that the single-esthetic unit breast reconstruction presents significant advantages over the traditional two-esthetic units, due to inconspicuous flap reconstruction, better position of the inframammary fold, and more natural transition from native and reconstructed tissues. Moreover, patient self-evaluation of esthetic outcome and quality of life showed that single-esthetic unit reconstruction is associated with higher patient satisfaction, therefore should be considered the method of choice. © 2010 Wiley-Liss, Inc.
Fernström, A L; Sutian, W; Royo, F; Westlund, K; Nilsson, T; Carlsson, H-E; Paramastri, Y; Pamungkas, J; Sajuthi, D; Schapiro, S J; Hau, J
2008-11-01
The stress associated with transportation of non-human primates used in scientific research is an important but almost unexplored part of laboratory animal husbandry. The procedures and routines concerning transport are not only important for the animals' physical health but also for their mental health as well. The transport stress in cynomolgus monkeys (Macaca fascicularis) was studied in two experiments. In Experiment 1, 25 adult female cynomolgus monkeys were divided into five groups of five animals each that received different diets during the transport phase of the experiment. All animals were transported in conventional single animal transport cages with no visual or tactile contact with conspecifics. The animals were transported by lorry for 24 h at ambient temperatures ranging between 20 degrees C and 35 degrees C. Urine produced before, during and after transport was collected and analysed for cortisol by enzyme-linked immunosorbent assay (ELISA). All monkeys exhibited a significant increase in cortisol excretion per time unit during the transport and on the first day following transport.Although anecdotal reports concerning diet during transport, including the provision of fruits and/or a tranquiliser, was thought likely to influence stress responses, these were not corrobated by the present study. In Experiment 2, behavioural data were collected from 18 cynomolgus macaques before and after transfer from group cages to either single or pair housing, and also before and after a simulated transport, in which the animals were housed in transport cages. The single housed monkeys were confined to single transport cages and the pair housed monkeys were kept in their pairs in double size cages. Both pair housed and singly housed monkeys showed clear behavioural signs of stress soon after their transfer out of their group cages.However, stress-associated behaviours were more prevalent in singly housed animals than in pair housed animals, and these behaviours persisted for a longer time after the simulated transport housing event than in the pair housed monkeys. Our data confirm that the transport of cynomolgus monkeys is stressful and suggest that it would be beneficial for the cynomolgus monkeys to be housed and transported in compatible pairs from the time they leave their group cages at the source country breeding facility until they arrive at their final laboratory destination in the country of use.
Ashton, Susan Elizabeth; Roe, Brenda; Jack, Barbara; McClelland, Bob
2016-09-01
End of life decisions for people with advanced dementia are reported as often being difficult for families as they attempt to make appropriate and justified decisions. To explore the experiences of advance care planning amongst family caregivers of people with advanced dementia. Qualitative research including a series of single cases (close family relatives). A purposive sample of 12 family caregivers within a specialist dementia unit was interviewed about their experiences of advance care planning between August 2009 and February 2010. Family caregivers need encouragement to ask the right questions during advance care planning to discuss the appropriateness of nursing and medical interventions at the end of life. Advance care planning can be facilitated with the family caregiver in the context of everyday practice within the nursing home environment for older people with dementia. © The Author(s) 2014.
The experiences of patients and carers living.
Leeder, Stephen R; Jowsey, Tanisha; McNab, Justin W
2018-01-01
Non-communicable diseases (NCDs) are increasing in prevalence and straining health systems globally. This creates a so-called 'burden of disease', which can be traced in terms of fiscal health system matters and in terms of quality of life and lived experiences of people with NCDs. The United Nations has called for a global agenda to manage NCDs and reduce their burden. The purpose of this article is to summarise key findings from the Serious and Continuing Illness Policy and Practice Study concerning patients’ and carers’ experiences of multimorbid NCDs in Australia. We focus on the relevance of findings for policy and general practitioners in Australia. We suggest that a complex multimorbidity policy is needed to contextualise and guide single-illness NCD policies. Our research suggests that specialist NCD nurses and allied health professionals could have important roles in improving care coordination between general practices and community health centres.
Using wave intensity analysis to determine local reflection coefficient in flexible tubes.
Li, Ye; Parker, Kim H; Khir, Ashraf W
2016-09-06
It has been shown that reflected waves affect the shape and magnitude of the arterial pressure waveform, and that reflected waves have physiological and clinical prognostic values. In general the reflection coefficient is defined as the ratio of the energy of the reflected to the incident wave. Since pressure has the units of energy per unit volume, arterial reflection coefficient are traditionally defined as the ratio of reflected to the incident pressure. We demonstrate that this approach maybe prone to inaccuracies when applied locally. One of the main objectives of this work is to examine the possibility of using wave intensity, which has units of energy flux per unit area, to determine the reflection coefficient. We used an in vitro experimental setting with a single inlet tube joined to a second tube with different properties to form a single reflection site. The second tube was long enough to ensure that reflections from its outlet did not obscure the interactions of the initial wave. We generated an approximately half sinusoidal wave at the inlet of the tube and took measurements of pressure and flow along the tube. We calculated the reflection coefficient using wave intensity (R dI and R dI 0.5 ) and wave energy (R I and R I 0.5 ) as well as the measured pressure (R dP ) and compared these results with the reflection coefficient calculated theoretically based on the mechanical properties of the tubes. The experimental results show that the reflection coefficients determined by all the techniques we studied increased or decreased with distance from the reflection site, depending on the type of reflection. In our experiments, R dP , R dI 0.5 and R I 0.5 are the most reliable parameters to measure the mean reflection coefficient, whilst R dI and R I provide the best measure of the local reflection coefficient, closest to the reflection site. Additional work with bifurcations, tapered tubes and in vivo experiments are needed to further understand, validate the method and assess its potential clinical use. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
The minimal flow unit in near-wall turbulence
NASA Technical Reports Server (NTRS)
Jimeez, Javier; Moin, Parviz
1991-01-01
Direct numerical simulations of unsteady channel flow were performed at low to moderate Reynolds numbers on computational boxes chosen small enough so that the flow consists of a doubly periodic (in x and z) array of identical structures. The goal is to isolate the basic flow unit, to study its morphology and dynamics, and to evaluate its contribution to turbulence in fully developed channels. For boxes wider than approximately 100 wall units in the spanwise direction, the flow is turbulent, and the low-order turbulence statistics are in good agreement with experiments in the near-wall region. For a narrow range of widths below that threshold, the flow near only one wall remains turbulent, but its statistics are still in fairly good agreement with experimental data when scaled with the local wall stress. For narrower boxes only laminar solutions are found. In all cases, the elementary box contains a single low-velocity streak, consisting of a longitudinal strip on which a thin layer of spanwise vorticity is lifted away from the wall.
Solid oxide fuel cell with multi-unit construction and prismatic design
McPheeters, C.C.; Dees, D.W.; Myles, K.M.
1999-03-16
A single cell unit of a solid oxide fuel cell is described that is individually fabricated and sintered prior to being connected to adjacent cells to form a solid oxide fuel cell. The single cell unit is comprised of a shaped anode sheet positioned between a flat anode sheet and an anode-electrolyte-cathode (A/E/C) sheet, and a shaped cathode sheet positioned between the A/E/C sheet and a cathode-interconnect-anode (C/I/A) sheet. An alternate embodiment comprises a shaped cathode sheet positioned between an A/E/C sheet and a C/I/A sheet. The shaped sheets form channels for conducting reactant gases. Each single cell unit is individually sintered to form a finished sub-assembly. The finished sub-assemblies are connected in electrical series by interposing connective material between the end surfaces of adjacent cells, whereby individual cells may be inspected for defects and interchanged with non-defective single cell units. 7 figs.
Culturing immobilized plant cells for the TUBUL space experiments on the DELTA and 12S Missions
NASA Astrophysics Data System (ADS)
Sieberer, Björn J.; Emons, Anne Mie C.; Vos, Jan W.
2007-09-01
For the TUBUL experiments during the DELTA mission in April 2004 and 12S mission in March/April 2006 on board the Soyuz capsule and the International Space Station we developed a method to culture and chemically fix plant suspension culture cells. The aim of the ten day experiment was to investigate the effect of microgravity on single plant cells. Fully automated experiment cassettes (Plunger Box Units) were developed by Centre for Concepts in Mechatronics (Nuenen, the Netherlands). Tobacco BY- 2 cells were immobilized in a semi- solid agarose matrix that was reinforced by a nylon mesh. This assembly allowed liquid medium refreshment, oxygen supply and chemical fixation, including a post- fixative wash. The method was optimized for post- flight analysis of cell structure, shape and size, cell division, and the microtubule cytoskeleton. The viability of cells in the agarose matrix was similar to cells grown in liquid medium under laboratory conditions, only the stationary growth phase was reached six days later.
Scientist, Single Cell Analysis Facility | Center for Cancer Research
The Cancer Research Technology Program (CRTP) develops and implements emerging technology, cancer biology expertise and research capabilities to accomplish NCI research objectives. The CRTP is an outward-facing, multi-disciplinary hub purposed to enable the external cancer research community and provides dedicated support to NCI’s intramural Center for Cancer Research (CCR). The dedicated units provide electron microscopy, protein characterization, protein expression, optical microscopy and nextGen sequencing. These research efforts are an integral part of CCR at the Frederick National Laboratory for Cancer Research (FNLCR). CRTP scientists also work collaboratively with intramural NCI investigators to provide research technologies and expertise. KEY ROLES AND RESPONSIBILITIES We are seeking a highly motivated Scientist II to join the newly established Single Cell Analysis Facility (SCAF) of the Center for Cancer Research (CCR) at NCI. The SCAF will house state of the art single cell sequencing technologies including 10xGenomics Chromium, BD Genomics Rhapsody, DEPPArray, and other emerging single cell technologies. The Scientist: Will interact with close to 200 laboratories within the CCR to design and carry out single cell experiments for cancer research Will work on single cell isolation/preparation from various tissues and cells and related NexGen sequencing library preparation Is expected to author publications in peer reviewed scientific journals
Motor unit recruitment in human genioglossus muscle in response to hypercapnia.
Nicholas, Christian L; Bei, Bei; Worsnop, Christopher; Malhotra, Atul; Jordan, Amy S; Saboisky, Julian P; Chan, Julia K M; Duckworth, Ella; White, David P; Trinder, John
2010-11-01
single motor unit recordings of the genioglossus (GG) muscle indicate that GG motor units have a variety of discharge patterns, including units that have higher discharge rates during inspiration (inspiratory phasic and inspiratory tonic), or expiration (expiratory phasic and expiratory tonic), or do not modify their rate with respiration (tonic). Previous studies have shown that an increase in GG muscle activity is a consequence of increased activity in inspiratory units. However, there are differences between studies as to whether this increase is primarily due to recruitment of new motor units (motor unit recruitment) or to increased discharge rate of already active units (rate coding). Sleep-wake state studies in humans have suggested the former, while hypercapnia experiments in rats have suggested the latter. In this study, we investigated the effect of hypercapnia on GG motor unit activity in humans during wakefulness. sleep research laboratory. sixteen healthy men. each participant was administered at least 6 trials with P(et)CO(2) being elevated 8.4 (SD = 1.96) mm Hg over 2 min following a 30-s baseline. Subjects were instrumented for GG EMG and respiratory measurements with 4 fine wire electrodes inserted subcutaneously into the muscle. One hundred forty-one motor units were identified during the baseline: 47% were inspiratory modulated, 29% expiratory modulated, and 24% showed no respiratory related modulation. Sixty-two new units were recruited during hypercapnia. The distribution of recruited units was significantly different from the baseline distribution, with 84% being inspiratory modulated (P < 0.001). Neither units active during baseline, nor new units recruited during hypercapnia, increased their discharge rate as P(et)CO(2) increased (P > 0.05 for all comparisons). increased GG muscle activity in humans occurs because of recruitment of previously inactive inspiratory modulated units.
The AMchip04 and the processing unit prototype for the FastTracker
NASA Astrophysics Data System (ADS)
Andreani, A.; Annovi, A.; Beretta, M.; Bogdan, M.; Citterio, M.; Alberti, F.; Giannetti, P.; Lanza, A.; Magalotti, D.; Piendibene, M.; Shochet, M.; Stabile, A.; Tang, J.; Tompkins, L.; Volpi, G.
2012-08-01
Modern experiments search for extremely rare processes hidden in much larger background levels. As the experiment`s complexity, the accelerator backgrounds and luminosity increase we need increasingly complex and exclusive event selection. We present the first prototype of a new Processing Unit (PU), the core of the FastTracker processor (FTK). FTK is a real time tracking device for the ATLAS experiment`s trigger upgrade. The computing power of the PU is such that a few hundred of them will be able to reconstruct all the tracks with transverse momentum above 1 GeV/c in ATLAS events up to Phase II instantaneous luminosities (3 × 1034 cm-2 s-1) with an event input rate of 100 kHz and a latency below a hundred microseconds. The PU provides massive computing power to minimize the online execution time of complex tracking algorithms. The time consuming pattern recognition problem, generally referred to as the ``combinatorial challenge'', is solved by the Associative Memory (AM) technology exploiting parallelism to the maximum extent; it compares the event to all pre-calculated ``expectations'' or ``patterns'' (pattern matching) simultaneously, looking for candidate tracks called ``roads''. This approach reduces to a linear behavior the typical exponential complexity of the CPU based algorithms. Pattern recognition is completed by the time data are loaded into the AM devices. We report on the design of the first Processing Unit prototypes. The design had to address the most challenging aspects of this technology: a huge number of detector clusters (``hits'') must be distributed at high rate with very large fan-out to all patterns (10 Million patterns will be located on 128 chips placed on a single board) and a huge number of roads must be collected and sent back to the FTK post-pattern-recognition functions. A network of high speed serial links is used to solve the data distribution problem.
Variation in orgasm occurrence by sexual orientation in a sample of U.S. singles.
Garcia, Justin R; Lloyd, Elisabeth A; Wallen, Kim; Fisher, Helen E
2014-11-01
Despite recent advances in understanding orgasm variation, little is known about ways in which sexual orientation is associated with men's and women's orgasm occurrence. To assess orgasm occurrence during sexual activity across sexual orientation categories. Data were collected by Internet questionnaire from 6,151 men and women (ages 21-65+ years) as part of a nationally representative sample of single individuals in the United States. Analyses were restricted to a subsample of 2,850 singles (1,497 men, 1,353 women) who had experienced sexual activity in the past 12 months. Participants reported their sex/gender, self-identified sexual orientation (heterosexual, gay/lesbian, bisexual), and what percentage of the time they experience orgasm when having sex with a familiar partner. Mean occurrence rate for experiencing orgasm during sexual activity with a familiar partner was 62.9% among single women and 85.1% among single men, which was significantly different (F1,2848 = 370.6, P < 0.001, η(2) = 0.12). For men, mean occurrence rate of orgasm did not vary by sexual orientation: heterosexual men 85.5%, gay men 84.7%, bisexual men 77.6% (F2,1494 = 2.67, P = 0.07, η(2) = 0.004). For women, however, mean occurrence rate of orgasm varied significantly by sexual orientation: heterosexual women 61.6%, lesbian women 74.7%, bisexual women 58.0% (F2,1350 = 10.95, P < 0.001, η(2) = 0.02). Lesbian women had a significantly higher probability of orgasm than did either heterosexual or bisexual women (P < 0.05). Findings from this large dataset of U.S. singles suggest that women, regardless of sexual orientation, have less predictable, more varied orgasm experiences than do men and that for women, but not men, the likelihood of orgasm varies with sexual orientation. These findings demonstrate the need for further investigations into the comparative sexual experiences and sexual health outcomes of sexual minorities. © 2014 International Society for Sexual Medicine.
Is the Orthographic/Phonological Onset a Single Unit in Reading Aloud?
ERIC Educational Resources Information Center
Mousikou, Petroula; Coltheart, Max; Saunders, Steven; Yen, Lisa
2010-01-01
Two main theories of visual word recognition have been developed regarding the way orthographic units in printed words map onto phonological units in spoken words. One theory suggests that a string of single letters or letter clusters corresponds to a string of phonemes (Coltheart, 1978; Venezky, 1970), while the other suggests that a string of…
Encoding of Spatial Attention by Primate Prefrontal Cortex Neuronal Ensembles
Treue, Stefan
2018-01-01
Abstract Single neurons in the primate lateral prefrontal cortex (LPFC) encode information about the allocation of visual attention and the features of visual stimuli. However, how this compares to the performance of neuronal ensembles at encoding the same information is poorly understood. Here, we recorded the responses of neuronal ensembles in the LPFC of two macaque monkeys while they performed a task that required attending to one of two moving random dot patterns positioned in different hemifields and ignoring the other pattern. We found single units selective for the location of the attended stimulus as well as for its motion direction. To determine the coding of both variables in the population of recorded units, we used a linear classifier and progressively built neuronal ensembles by iteratively adding units according to their individual performance (best single units), or by iteratively adding units based on their contribution to the ensemble performance (best ensemble). For both methods, ensembles of relatively small sizes (n < 60) yielded substantially higher decoding performance relative to individual single units. However, the decoder reached similar performance using fewer neurons with the best ensemble building method compared with the best single units method. Our results indicate that neuronal ensembles within the LPFC encode more information about the attended spatial and nonspatial features of visual stimuli than individual neurons. They further suggest that efficient coding of attention can be achieved by relatively small neuronal ensembles characterized by a certain relationship between signal and noise correlation structures. PMID:29568798
Nakajima, Tsuyoshi; Tazoe, Toshiki; Sakamoto, Masanori; Endoh, Takashi; Shibuya, Satoshi; Elias, Leonardo A.; Mezzarane, Rinaldo A.; Komiyama, Tomoyoshi; Ohki, Yukari
2017-01-01
Corticospinal excitation is mediated by polysynaptic pathways in several vertebrates, including dexterous monkeys. However, indirect non-monosynaptic excitation has not been clearly observed following transcranial electrical stimulation (TES) or cervicomedullary stimulation (CMS) in humans. The present study evaluated indirect motor pathways in normal human subjects by recording the activities of single motor units (MUs) in the biceps brachii (BB) muscle. The pyramidal tract was stimulated with weak TES, CMS, and transcranial magnetic stimulation (TMS) contralateral to the recording side. During tasks involving weak co-contraction of the BB and hand muscles, all stimulation methods activated MUs with short latencies. Peristimulus time histograms (PSTHs) showed that responses with similar durations were induced by TES (1.9 ± 1.4 ms) and CMS (2.0 ± 1.4 ms), and these responses often showed multiple peaks with the PSTH peak having a long duration (65.3% and 44.9%, respectively). Such long-duration excitatory responses with multiple peaks were rarely observed in the finger muscles following TES or in the BB following stimulation of the Ia fibers. The responses obtained with TES were compared in the same 14 BB MUs during the co-contraction and isolated BB contraction tasks. Eleven and three units, respectively, exhibited activation with multiple peaks during the two tasks. In order to determine the dispersion effects on the axon conduction velocities (CVs) and synaptic noise, a simulation study that was comparable to the TES experiments was performed with a biologically plausible neuromuscular model. When the model included the monosynaptic-pyramidal tract, multiple peaks were obtained in about 34.5% of the motoneurons (MNs). The experimental and simulation results indicated the existence of task-dependent disparate inputs from the pyramidal tract to the MNs of the upper limb. These results suggested that intercalated interneurons are present in the spinal cord and that these interneurons might be equivalent to those identified in animal experiments. PMID:28194103
Dağgülli, Mansur; Sancaktutar, Ahmet Ali; Dede, Onur; Utanğaç, Mehmet Mazhar; Bodakçi, Mehmet Nuri; Penbegül, Necmettin; Hatipoğlu, Namık Kemal; Çakmakçı, Süleyman
2015-11-01
We aimed to present the outcomes of PNL surgery performed in infantile patients with small renal stones who were younger than 1 year of age. A single-center prospective trial was initiated and during the period between Jan 2013 and Jan 2015, PNL was applied to 20 renal units of 16 infants (6 girls and 10 boys), including 4 patients with bilateral kidney stones. PNL was performed in patients with renal stones larger than 2 cm, as well as stones resistant to SWL or renal stones that were undetectable during SWL. The mean age of the patients was 9.55 (5-12) months. Of the 20 renal units, 1 had complete staghorn stones, 3 had partial staghorn stones, 13 had renal pelvic stones, and 3 had lower pole stones. The mean stone size was 18.5 mm (range 12-36 mm). Mean operative time for PNL was 88 (25-135 min). Mean fluoroscopy time was estimated as 3.4 min. Mean hemoglobin loss was 0.72 g/L (0.2-3). The mean hospital stay was 4.1 days (2-8 days). On postoperative day 1, a complete stone-free state was achieved in 70% of renal units (14 of 20). At the end of the first postoperative week, the remaining two patients had insignificant residual fragments of 3 mm and were followed conservatively without any specific intervention. Thus, the total SFR was 80% (16 of 20) at discharge. In infants aged less than 1 year, minimal access tract dilation during PNL, the use of smaller caliber pediatric instruments, and the realization of this procedure by surgeons with adequate experience in adults carry utmost importance. In addition, special care should be taken to avoid hypothermia and radiation exposure during PNL.
Van Nimwegen, W G; Raghoebar, G M; Tymstra, N; Vissink, A; Meijer, H J A
2017-06-01
To conduct a systematic review on the clinical outcome of single implant-supported two-unit cantilever FDP's and to conduct a 5-year prospective comparative pilot study of patients with a missing central and lateral upper incisor treated with either a single implant-supported two-unit cantilever FDP or two implants with solitary implant crowns in the aesthetic zone. Medline, Embase and the Cochrane Central Register of Controlled Trials were searched (last search 1 August 2016) for eligible studies. In the comparative pilot study, an implant-cantilever group of five patients with a single implant-supported two-unit cantilever FDP (NobelReplace Groovy Regular Platform) was compared with an implant-implant group of five patients with two adjacent single implant-supported crowns (NobelReplace Groovy Regular Platform) in the aesthetic zone. Implant survival, marginal bone level (MBL) changes, pocket probing depth, papilla index and patient satisfaction were assessed during a 5-year follow-up period. Five of 276 articles were considered eligible for data extraction. Implant survival ranged from 96·6% to 100%. Marginal bone level changes were higher in the anterior region than in the posterior region. Technical complications occurred more often in the posterior than anterior region. In the 5-year comparative pilot study, no clinically significant differences in hard and soft peri-implant tissue levels occurred between both groups. Single implant-supported two-unit cantilever FDP's can be a viable alternative to the placement of two adjacent single implant crowns in the aesthetic zone. Due to technical complications, placement of two-unit cantilever crowns in the posterior region can be considered unwise. © 2017 John Wiley & Sons Ltd.
Impact of long term cryopreservation on single umbilical cord blood transplant outcomes
Mitchell, R.; Wagner, J.E.; Brunstein, C.G.; Cao, Q.; McKenna, D.H.; Lund, T.C.; Verneris, M.R.
2015-01-01
Umbilical cord blood (UCB) has the advantage of being collected and cryopreserved for years prior to use. In vitro or in murine models suggest that the duration of storage does not affect UCB progenitor cell performance, however the impact of UCB age on clinical outcomes has not been definitely defined. This study sought to determine the effect of UCB unit cryopreservation time on hematopoietic potency. We analyzed 288 single UCB units used for transplantation from 1992–2013, with unit cryopreservation time ranging from 0.08 to 11.07 years. UCB unit post thaw characteristics were examined, including percent recovery of total nucleated cells (TNC). The number of years the UCB unit spent in cryopreservation had no impact on TNC recovery nor UCB unit post-thaw viability. Duration of cryopreservation also had no impact on neutrophil or platelet engraftment in single UCB transplants. These results show that UCB units can undergo cryopreservation for at least 10 years with no impact on clinical outcomes. PMID:25262882
Zorn, Kevin C; Gofrit, Ofer N; Orvieto, Marcelo A; Mikhail, Albert A; Galocy, R Matthew; Shalhav, Arieh L; Zagaja, Gregory P
2007-11-01
Previous reports have suggested that a 2% to 5% device failure rate (FR) be quoted when counseling patients about robot-assisted laparoscopic radical prostatectomy (RLRP). We sought to evaluate our FR on the da Vinci system. Since February 2003, more than 800 RLRPs have been performed at our institution using a single three-armed robotic unit. A prospective database was analyzed to determine the device FR and whether it resulted in case abortion or open conversion. Intuitive Surgical Systems provided data concerning the system's performance, including its fault rate. Error messages were classified as recoverable and non-recoverable faults. Between February 2003 and November 2006, 725 RLRP cases were available for evaluation. There were no intraoperative device failures that resulted in a case conversion. Technical errors resulting in surgeon handicap occurred in 3 cases (0.4%). Four patients (0.5%) had their procedures aborted secondary to system failure at initial set-up prior to patient entrance to the operating room. Data analysis retrieved from the da Vinci console reported on a total of 807 procedures since 2003. Only 4 cases (0.4%) were reported from the Intuitive Surgical database to result in either an aborted or a converted case, which compares favorably with our results. Since the last computer system upgrade (September 2005), the mean recoverable and non-recoverable fault rates per procedure were 0.21 and 0.05, respectively. For all the advanced features the da Vinci system offers, it is surprisingly reliable. Throughout our RLRP experience, device failure resulted in case conversion, procedure abortion, and surgeon handicap in 0, 0.5%, and 0.4% of procedures, respectively. As such, a lowered device FR of 0.5% should be used when counseling patients undergoing RLRP. To avoid futile general anesthesia, a policy should be enforced to ensure that the da Vinci system is completely set up before the patient enters the operating room.
NASA Astrophysics Data System (ADS)
Yano, Sachiko; Kasahara, Haruo; Masuda, Daisuke; Tanigaki, Fumiaki; Shimazu, Toru; Suzuki, Hiromi; Karahara, Ichirou; Soga, Kouichi; Hoson, Takayuki; Tayama, Ichiro; Tsuchiya, Yoshikazu; Kamisaka, Seiichiro
2013-03-01
In 2004, Japan Aerospace Exploration Agency developed the engineered model of the Plant Experiment Unit and the Cell Biology Experiment Facility. The Plant Experiment Unit was designed to be installed in the Cell Biology Experiment Facility and to support the seed-to-seed life cycle experiment of Arabidopsis plants in space in the project named Space Seed. Ground-based experiments to test the Plant Experiment Unit showed that the unit needed further improvement of a system to control the water content of a seedbed using an infrared moisture analyzer and that it was difficult to keep the relative humidity inside the Plant Experiment Unit between 70 and 80% because the Cell Biology Experiment Facility had neither a ventilation system nor a dehumidifying system. Therefore, excess moisture inside the Cell Biology Experiment Facility was removed with desiccant bags containing calcium chloride. Eight flight models of the Plant Experiment Unit in which dry Arabidopsis seeds were fixed to the seedbed with gum arabic were launched to the International Space Station in the space shuttle STS-128 (17A) on August 28, 2009. Plant Experiment Unit were installed in the Cell Biology Experiment Facility with desiccant boxes, and then the Space Seed experiment was started in the Japanese Experiment Module, named Kibo, which was part of the International Space Station, on September 10, 2009 by watering the seedbed and terminated 2 months later on November 11, 2009. On April 19, 2010, the Arabidopsis plants harvested in Kibo were retrieved and brought back to Earth by the space shuttle mission STS-131 (19A). The present paper describes the Space Seed experiment with particular reference to the development of the Plant Experiment Unit and its actual performance in Kibo onboard the International Space Station. Downlinked images from Kibo showed that the seeds had started germinating 3 days after the initial watering. The plants continued growing, producing rosette leaves, inflorescence stems, flowers, and fruits in the Plant Experiment Unit. In addition, the senescence of rosette leaves was found to be delayed in microgravity.
ERP Subsequent Memory Effects Differ between Inter-Item and Unitization Encoding Tasks
Kamp, Siri-Maria; Bader, Regine; Mecklinger, Axel
2017-01-01
The “subsequent memory paradigm” is an analysis tool to identify brain activity elicited during episodic encoding that is associated with successful subsequent retrieval. Two commonly observed event-related potential “subsequent memory effects” (SMEs) are the parietal SME in the P300 time window and the frontal slow wave SME, but to date a clear characterization of the circumstances under which each SME is observed is missing. To test the hypothesis that the parietal SME occurs when aspects of an experience are unitized into a single item representation, while inter-item associative encoding is reflected in the frontal slow wave effect, participants were assigned to one of two conditions that emphasized one of the encoding types under otherwise matched study phases of a recognition memory experiment. Word pairs were presented either in the context of a definition that allowed to combine the word pairs into a new concept (unitization or item encoding) or together with a sentence frame (inter-item encoding). Performance on the recognition test did not differ between the groups. The parietal SME was only found in the definition group, supporting the idea that this SME occurs when the components of an association are integrated in a unitized item representation. An early prefrontal negativity also exhibited an SME only in this group, suggesting that the formation of novel units occurs through interactions of multiple brain areas. The frontal slow wave SME was pronounced in both groups and may thus reflect processes generally involved in encoding of associations. Our results provide evidence for a partial dissociation of the eliciting conditions of the two types of SMEs and therefore provide a tool for future studies to characterize the different types of episodic encoding. PMID:28194105
ERP Subsequent Memory Effects Differ between Inter-Item and Unitization Encoding Tasks.
Kamp, Siri-Maria; Bader, Regine; Mecklinger, Axel
2017-01-01
The "subsequent memory paradigm" is an analysis tool to identify brain activity elicited during episodic encoding that is associated with successful subsequent retrieval. Two commonly observed event-related potential "subsequent memory effects" (SMEs) are the parietal SME in the P300 time window and the frontal slow wave SME, but to date a clear characterization of the circumstances under which each SME is observed is missing. To test the hypothesis that the parietal SME occurs when aspects of an experience are unitized into a single item representation, while inter-item associative encoding is reflected in the frontal slow wave effect, participants were assigned to one of two conditions that emphasized one of the encoding types under otherwise matched study phases of a recognition memory experiment. Word pairs were presented either in the context of a definition that allowed to combine the word pairs into a new concept (unitization or item encoding) or together with a sentence frame (inter-item encoding). Performance on the recognition test did not differ between the groups. The parietal SME was only found in the definition group, supporting the idea that this SME occurs when the components of an association are integrated in a unitized item representation. An early prefrontal negativity also exhibited an SME only in this group, suggesting that the formation of novel units occurs through interactions of multiple brain areas. The frontal slow wave SME was pronounced in both groups and may thus reflect processes generally involved in encoding of associations. Our results provide evidence for a partial dissociation of the eliciting conditions of the two types of SMEs and therefore provide a tool for future studies to characterize the different types of episodic encoding.
Fermi surface properties of paramagnetic NpCd11 with a large unit cell
NASA Astrophysics Data System (ADS)
Homma, Yoshiya; Aoki, Dai; Haga, Yoshinori; Settai, Rikio; Sakai, Hironori; Ikeda, Shugo; Yamamoto, Etsuji; Nakamura, Akio; Shiokawa, Yoshinobu; Takeuchi, Tetsuya; Yamagami, Hiroshi; Ōnuki, Yoshichika
2010-03-01
We succeeded in growing a high-quality single crystal of NpCd11 with the cubic BaHg11-type structure by the Cd-self flux method. The lattice parameter of a = 9.2968(2) Å and crystallographic positions of the atoms were determined by x-ray single-crystal structure analysis. From the results of the magnetic susceptibility and specific heat experiments, this compound is found to be a 5f-localized paramagnet with the singlet ground state in the crystalline electric field (CEF) scheme. Fermi surface properties were measured using the de Haas-van Alphen (dHvA) technique. Long-period oscillations were observed in the dHvA frequency range of 9.1 x 105 to 1.9 x 107 Oe, indicating small cross-sectional areas of Fermi surfaces, which is consistent with a small Brillouin zone based on a large unit cell. From the results of dHvA and magnetoresistance experiments, the Fermi surface of NpCd11 is found to consist of many kinds of closed Fermi surfaces and a multiply-connected-like Fermi surface, although the result of energy band calculations based on the 5f-localized Np3+(5f4) configuration reveals the existence of only closed Fermi surfaces. The corresponding cyclotron effective mass is small, ranging from 0.1 to 0.7 m0, which is consistent with a small electronic specific heat coefficient γ ≅ 10mJ/K2·mol, revealing no hybridization between the 5f electrons and conduction electrons.
Preferred mental models in reasoning about spatial relations.
Jahn, Georg; Knauff, Markus; Johnson-Laird, P N
2007-12-01
The theory of mental models postulates that individuals infer that a spatial description is consistent only if they can construct a model in which all the assertions in the description are true. Individuals prefer a parsimonious representation, and so, when a description is consistent with more than one possible layout of entities on the left-right dimension, individuals in our culture prefer to construct models working from left to right. They also prefer to locate entities referred to in the same assertion as adjacent to one another in a model. And, if possible, they tend to chunk entities into a single unit in order to capture several possibilities in a single model. We report four experiments corroborating these predictions. The results shed light on the integration of relational assertions, and they show that participants exploit implicit constraints in building models of spatial relations.
Common Risk Criteria Standards for National Test Ranges
2017-09-01
critical assets. Equipment and facilities that comprise part of an on- or off-base renewable energy system, such as wind turbine generation facilities...to be protected. As an example, for a wind turbine farm, the unit component would be a single wind turbine . A unit component can be considered...functionality of the larger system to which the unit component belongs. For example, a single wind turbine is a unit component of a wind turbine farm. A
ACS experiment for atmospheric studies on "ExoMars-2016" Orbiter
NASA Astrophysics Data System (ADS)
Korablev, O. I.; Montmessin, F.; Fedorova, A. A.; Ignatiev, N. I.; Shakun, A. V.; Trokhimovskiy, A. V.; Grigoriev, A. V.; Anufreichik, K. A.; Kozlova, T. O.
2015-12-01
ACS is a set of spectrometers for atmospheric studies (Atmospheric Chemistry Suite). It is one of the Russian instruments for the Trace Gas Orbiter (TGO) of the Russian-European "ExoMars" program. The purpose of the experiment is to study the Martian atmosphere by means of two observations regimes: sensitive trace gases measurements in solar occultations and by monitoring the atmospheric state during nadir observations. The experiment will allow us to approach global problems of Mars research such as current volcanism, and the modern climate status and its evolution. Also, the experiment is intended to solve the mystery of methane presence in the Martian atmosphere. Spectrometers of the ACS set cover the spectral range from the near IR-range (0.7 μm) to the thermal IR-range (17 μm) with spectral resolution λ/Δλ reaching 50000. The ACS instrument consists of three independent IR spectrometers and an electronics module, all integrated in a single unit with common mechanical, electrical and thermal interfaces. The article gives an overview of scientific tasks and presents the concept of the experiment.
Growth of Solid Solution Single Crystals
NASA Technical Reports Server (NTRS)
Lehoczky, Sandor L.; Szofran, F. R.; Gillies, Donald C.
2001-01-01
The solidification of a solid solution semiconductor, having a wide separation between liquidus and solidus has been extensively studied in ground based, high magnetic field and Spacelab experiments. Two alloys of mercury cadmium telluride have been studied; with 80.0 mole percent of HgTe and 84.8 mole percent of HgTe respectively, the remainder being cadmium telluride. Such alloys are extremely difficult to grow by directional solidification on earth due to high solutal and thermal density differences that give rise to fluid flow and consequent loss of interface shape and composition. Diffusion controlled growth is therefore impossible to achieve in conventional directional solidification. The ground based experiments consisted of growing crystals in several different configurations of heat pipe furnaces, NASA's Advanced Automated Directional Solidification Furnace (AADSF), and a similar furnace incorporated in a superconducting magnet capable of operating at up to 5T. The first microgravity experiment took place during the flight of STS-62 in March 1994, with the AADSF installed on the second United States Microgravity Payload (USMP-2). The alloy was solidified at 3/4 inch per day over a 9 day period, and for the first time a detailed evaluation was performed correlating composition variations to measured residual acceleration. The second flight experiment took place in the fourth United States Microgravity Payload Mission (USMP-4) in November 1997. Due to contamination of the furnace system, analysis shows that the conditions prevailing during the experiment were quite different from the requirements requested prior to the mission. The results indicate that the sample did accomplish the desired objectives.
Action Potential Waveform Variability Limits Multi-Unit Separation in Freely Behaving Rats
Stratton, Peter; Cheung, Allen; Wiles, Janet; Kiyatkin, Eugene; Sah, Pankaj; Windels, François
2012-01-01
Extracellular multi-unit recording is a widely used technique to study spontaneous and evoked neuronal activity in awake behaving animals. These recordings are done using either single-wire or mulitwire electrodes such as tetrodes. In this study we have tested the ability of single-wire electrodes to discriminate activity from multiple neurons under conditions of varying noise and neuronal cell density. Using extracellular single-unit recording, coupled with iontophoresis to drive cell activity across a wide dynamic range, we studied spike waveform variability, and explored systematic differences in single-unit spike waveform within and between brain regions as well as the influence of signal-to-noise ratio (SNR) on the similarity of spike waveforms. We also modelled spike misclassification for a range of cell densities based on neuronal recordings obtained at different SNRs. Modelling predictions were confirmed by classifying spike waveforms from multiple cells with various SNRs using a leading commercial spike-sorting system. Our results show that for single-wire recordings, multiple units can only be reliably distinguished under conditions of high recording SNR (≥4) and low neuronal density (≈20,000/ mm3). Physiological and behavioural changes, as well as technical limitations typical of awake animal preparations, reduce the accuracy of single-channel spike classification, resulting in serious classification errors. For SNR <4, the probability of misclassifying spikes approaches 100% in many cases. Our results suggest that in studies where the SNR is low or neuronal density is high, separation of distinct units needs to be evaluated with great caution. PMID:22719894
Prefrontal single-unit firing associated with deficient extinction in mice
Fitzgerald, Paul J; Whittle, Nigel; Flynn, Shaun M; Graybeal, Carolyn; Pinard, Courtney; Gunduz-Cinar, Ozge; Kravitz, Alexxai; Singewald, Nicolas; Holmes, Andrew
2014-01-01
The neural circuitry mediating fear extinction has been increasingly well studied and delineated. The rodent infralimbic subregion (IL) of the ventromedial prefrontal cortex (vmPFC) has been found to promote extinction, whereas the prelimbic cortex (PL) demonstrates an opposing, pro-fear, function. Studies employing in vivo electrophysiological recordings have observed that while increased IL single-unit firing and bursting predicts robust extinction retrieval, increased PL firing can correlate with sustained fear and poor extinction. These relationships between single-unit firing and extinction do not hold under all experimental conditions, however. In the current study, we further investigated the relationship between vmPFC and PL single-unit firing and extinction using inbred mouse models of intact (C57BL/6J, B6) and deficient (129S1/SvImJ, S1) extinction strains. Simultaneous single-unit recordings were made in the PL and vmPFC (encompassing IL) as B6 and S1 mice performed extinction training and retrieval. Impaired extinction retrieval in S1 mice was associated with elevated PL single-unit firing, as compared to firing in extinguishing B6 mice, consistent with the hypothesized pro-fear contribution of PL. Analysis of local field potentials also revealed significantly higher gamma power in the PL of Sthan B6 mice during extinction training and retrieval. In the vmPFC, impaired extinction in S1 mice was also associated with exaggerated single-unit firing, relative to B6 mice. This is in apparent contradiction to evidence that IL activity promotes extinction, but could reflect a (failed) compensatory effort by the vmPFC to mitigate fear-promoting activity in other regions, such as the PL or amygdala. In support of this hypothesis, augmenting IL activity via direct infusion of the GABAA receptor antagonist picrotoxin rescued impaired extinction retrieval in S1 mice. Chronic fluoxetine treatment produced modest reductions in fear during extinction retrieval and increased the number of Zif268-labeled cells in layer II of IL, but failed to increase vmPFC single-unit firing. Collectively, these findings further support the important contribution these cortical regions play in determining the balance between robust extinction on the one hand, and sustained fear on the other. Elucidating the precise nature of these roles could help inform understanding of the pathophysiology of fear-related anxiety disorders. PMID:24231425
Numerical and experimental analyses of the radiant heat flux produced by quartz heating systems
NASA Technical Reports Server (NTRS)
Turner, Travis L.; Ash, Robert L.
1994-01-01
A method is developed for predicting the radiant heat flux distribution produced by tungsten filament, tubular fused-quartz envelope heating systems with reflectors. The method is an application of Monte Carlo simulation, which takes the form of a random walk or ray tracing scheme. The method is applied to four systems of increasing complexity, including a single lamp without a reflector, a single lamp with a Hat reflector, a single lamp with a parabolic reflector, and up to six lamps in a six-lamp contoured-reflector heating unit. The application of the Monte Carlo method to the simulation of the thermal radiation generated by these systems is discussed. The procedures for numerical implementation are also presented. Experiments were conducted to study these quartz heating systems and to acquire measurements of the corresponding empirical heat flux distributions for correlation with analysis. The experiments were conducted such that several complicating factors could be isolated and studied sequentially. Comparisons of the experimental results with analysis are presented and discussed. Good agreement between the experimental and simulated results was obtained in all cases. This study shows that this method can be used to analyze very complicated quartz heating systems and can account for factors such as spectral properties, specular reflection from curved surfaces, source enhancement due to reflectors and/or adjacent sources, and interaction with a participating medium in a straightforward manner.
Universal Poisson Statistics of mRNAs with Complex Decay Pathways.
Thattai, Mukund
2016-01-19
Messenger RNA (mRNA) dynamics in single cells are often modeled as a memoryless birth-death process with a constant probability per unit time that an mRNA molecule is synthesized or degraded. This predicts a Poisson steady-state distribution of mRNA number, in close agreement with experiments. This is surprising, since mRNA decay is known to be a complex process. The paradox is resolved by realizing that the Poisson steady state generalizes to arbitrary mRNA lifetime distributions. A mapping between mRNA dynamics and queueing theory highlights an identifiability problem: a measured Poisson steady state is consistent with a large variety of microscopic models. Here, I provide a rigorous and intuitive explanation for the universality of the Poisson steady state. I show that the mRNA birth-death process and its complex decay variants all take the form of the familiar Poisson law of rare events, under a nonlinear rescaling of time. As a corollary, not only steady-states but also transients are Poisson distributed. Deviations from the Poisson form occur only under two conditions, promoter fluctuations leading to transcriptional bursts or nonindependent degradation of mRNA molecules. These results place severe limits on the power of single-cell experiments to probe microscopic mechanisms, and they highlight the need for single-molecule measurements. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
The More Things Change the More They Stay the Same: A Case Report of Neurology Residency Experiences
Ances, Beau
2012-01-01
This study compared the neurology residency training experience for a single neurology resident at the University of Pennsylvania from the years 2002–2005. The prevalence of encounters seen during this residency was compared to the prevalence of neurological disorders typically observed by ambulatory neurologists in the United States (US). A total of 1,333 patients were evaluated during this residency. Ischemic stroke/ transient ischemic accident, epilepsy, metabolic encephalopathy, peripheral neuropathy, and multiple sclerosis were the most common neurological disorders observed. The four most common reasons for an outpatient visit to a neurologist (i.e. headache/migraine, epilepsy, cerebrovascular disease, and peripheral neuropathy) typically account for ~ 49–55% of all appointments, but only contributed to ~40% of patient encounters during this neurology residency. While these results reflect the encounters of a single neurology resident, both the total number and distribution of neurological diagnoses were similar to previous experiences over two decades ago at US academic medical centers despite significant changes in health care delivery and policy. This case report demonstrates that neurology residency programs continue to overemphasize acute management of inpatient neurological disorders compared to outpatient care of more prevalent neurological complaints. Additional measures could be instituted to ensure a broader range of experiences during residency (i.e. online resident log). These methods could allow residency coordinators to identify certain areas of deficiency in regards to exposure to patients for a resident and ensure greater competency during residency. PMID:22186851
Vigolo, Paolo; Mutinelli, Sabrina
2012-06-01
The purpose of this prospective clinical study was to determine the success rate of single-unit posterior fixed dental prostheses (FDPs) with zirconia copings generated with two CAD/CAM systems, compared to porcelain-fused-to-metal (PFM) single-unit posterior FDPs after 5 years of function. From 2005 to 2006, 60 patients who needed a single-unit FDP on a first molar in the mandibular jaw (left or right) in a private office setting were included in this study. The 60 first mandibular molars were randomly divided into three groups (n = 20): in the control group (group C), 20 PFM FDPs were included. In the other two groups CAD/CAM technology was used for the fabrication of the zirconium-oxide copings: 20 single-unit posterior FDPs with zirconia copings were generated with the Procera system (group P, Nobel Biocare); 20 single-unit posterior FDPs with zirconia copings were generated with the Lava system (group L, 3M ESPE). For the ANOVA follow-up data, the clinical life table method was applied. The statistical analysis was performed using two nonparametric tests, the log-rank test for k-groups and the Fisher exact test. No statistically significant difference in the clinical outcome of zirconia-ceramic FDPs of both groups (P and L) evaluated together and metal-ceramic posterior single FDPs was found at 5 years of function; however, clinical data showed that technical problems, such as extended fracture of the veneering ceramic, tended to occur more frequently in the zirconia-ceramic FDP groups. The difference in the frequency of failure was statistically significant only in the comparison of groups C and P. Even if no statistically significant difference in the clinical outcome of zirconia-ceramic FDPs of both groups (P and L) considered together and metal-ceramic posterior single FDPs was found at 5 years of function, clinical data showed that the two zirconia-ceramic FDP groups tended to have more frequent clinical problems: for this reason all the clinical and technical variables related to the use of zirconia-ceramic FDPs generated with CAD/CAM systems should be carefully considered prior to all treatment procedures. © 2012 by the American College of Prosthodontists.
Stability tests at Browns Ferry Unit 1 under single-loop operating conditions
DOE Office of Scientific and Technical Information (OSTI.GOV)
March-Leuba, J.; Wood, R.T.; Otaduy, P.J.
1986-07-01
The results of neutronic stability tests performed on February 9, 1985, at the Browns Ferry Nuclear Power Plant Unit 1 under single-loop operation (SLO) conditions are documented. The main conclusions of the tests are presented.
Jamshaid, Anila; Ather, M Hammad; Hussain, Ghazi; Khawaja, Karim B
2008-11-01
This study compared the efficacy and safety profile of electrohydraulic (EH) and electromagnetic (EM) lithotriptors in the treatment of 10- to 20-mm renal and proximal ureteric stones at a single center and by a single operator. Between January 2001 and December 2006, we sequentially treated patients meeting study inclusion criteria with MPL 9000 Dornier EH for the first 3 years, followed by the EM Siemens Modularis shockwave lithotripsy (SWL) unit. A single operator performed all SWL treatments under the supervision of an admitting urologist. We analyzed the demographic features and stone- and treatment-related parameters including complications for both groups. In each group, the stone-free rate and efficiency quotient was determined at 1-3 months. Of 274 patients, we sequentially treated 112 using the EH lithotriptor, and 162 the EM lithotriptor. The pre-SWL patients and stone-related parameters were similar in the two groups, except for diagnostic imaging modalities. The mean number of SWL sessions, need for ancillary procedure, retreatment rate, stone location, stone-free rate, and efficiency quotient were not significantly different between groups. The mean number of shockwaves required for complete fragmentation was 2977 and 6044 (P < .000) for the EH and EM groups, respectively. Single center, single operator experience with two types of lithotriptor indicated that both are equally efficacious, with similar safety profiles. The only significant difference was that the EH lithotriptor required fewer shockwaves for fragmentation.
A Laser-Based Measuring System for Online Quality Control of Car Engine Block.
Li, Xing-Qiang; Wang, Zhong; Fu, Lu-Hua
2016-11-08
For online quality control of car engine production, pneumatic measurement instrument plays an unshakeable role in measuring diameters inside engine block because of its portability and high-accuracy. To the limitation of its measuring principle, however, the working space between the pneumatic device and measured surface is too small to require manual operation. This lowers the measuring efficiency and becomes an obstacle to perform automatic measurement. In this article, a high-speed, automatic measuring system is proposed to take the place of pneumatic devices by using a laser-based measuring unit. The measuring unit is considered as a set of several measuring modules, where each of them acts like a single bore gauge and is made of four laser triangulation sensors (LTSs), which are installed on different positions and in opposite directions. The spatial relationship among these LTSs was calibrated before measurements. Sampling points from measured shaft holes can be collected by the measuring unit. A unified mathematical model was established for both calibration and measurement. Based on the established model, the relative pose between the measuring unit and measured workpiece does not impact the measuring accuracy. This frees the measuring unit from accurate positioning or adjustment, and makes it possible to realize fast and automatic measurement. The proposed system and method were finally validated by experiments.
Chen, Yue; Gao, Qin; Song, Fei; Li, Zhizhong; Wang, Yufan
2017-08-01
In the main control rooms of nuclear power plants, operators frequently have to switch between procedure displays and system information displays. In this study, we proposed an operation-unit-based integrated design, which combines the two displays to facilitate the synthesis of information. We grouped actions that complete a single goal into operation units and showed these operation units on the displays of system states. In addition, we used different levels of visual salience to highlight the current unit and provided a list of execution history records. A laboratory experiment, with 42 students performing a simulated procedure to deal with unexpected high pressuriser level, was conducted to compare this design against an action-based integrated design and the existing separated-displays design. The results indicate that our operation-unit-based integrated design yields the best performance in terms of time and completion rate and helped more participants to detect unexpected system failures. Practitioner Summary: In current nuclear control rooms, operators frequently have to switch between procedure and system information displays. We developed an integrated design that incorporates procedure information into system displays. A laboratory study showed that the proposed design significantly improved participants' performance and increased the probability of detecting unexpected system failures.
Brown, James; McIntyre, Andrew; Gasparotto, Robyn; McGee, Therese M
2016-06-01
Many birth units use central fetal monitoring (CFM) under the assumption that greater surveillance improves perinatal outcomes. The unexpected loss of the CFM system at a tertiary unit provided a unique opportunity to evaluate outcomes and staff attitudes toward CFM. This retrospective cohort study compared patient data from 2,855 electronically monitored women delivering over a 12-month period, where CFM was available for the first 6 months but unavailable for the following 6 months. Primary outcomes relating to neonatal morbidity and secondary outcomes relating to intrapartum interventions were examined. Additionally, birth unit staff members were surveyed about aspects of care related to CFM. There were no significant differences in perinatal outcomes between the cohorts. While unadjusted analysis suggested a lower spontaneous vaginal birth rate (55.4% vs 60.3%) and a higher cesarean delivery rate (25.1% vs 22.0%, p = 0.026), together with higher epidural (53.0% vs 49.2%, p = 0.04) and fetal blood sampling (11.8% vs 9.4%, p = 0.03) rates in the presence of CFM, these differences were lost when adjusted for prostaglandin ripening. Over half of the staff (56.0% of midwives, 54.0% of obstetricians) reported spending more time with the laboring woman in the period without CFM. This single institution's experience indicates that in birth units staffed for one-to-one care in labor, central fetal monitoring does not appear to be associated with either a benefit on perinatal outcomes or an increase in cesarean delivery and other interventions. However, it is associated with a reduction in the time a midwife spends with the laboring woman. © 2016 Wiley Periodicals, Inc.
Structural studies on a high-pressure polymorph of NaYSi 2O 6
NASA Astrophysics Data System (ADS)
Kahlenberg, Volker; Konzett, Jürgen; Kaindl, Reinhard
2007-06-01
High-pressure synthesis experiments in the system Na 2O-Y 2O 3-SiO 2 revealed the existence of a previously unknown polymorph of NaYSi 2O 6 or Na 3Y 3[Si 3O 9] 2 which was quenched from 3.0 GPa and 1000 °C. Structural investigations on this modification have been performed using single-crystal X-ray diffraction data collected at ambient conditions. Furthermore, unpolarized micro-Raman spectra have been obtained from single-crystal material. The high-P modification of NaYSi 2O 6 crystallizes in the centrosymmetric space group C2/ c with 12 formula units per cell ( a=8.2131(9) Å, b=10.3983(14) Å, c=17.6542(21) Å, β=100.804(9)°, V=1481.0(3) Å 3, R(| F|)=0.033 for 1142 independent observed reflections) and belongs to the group of cyclo-silicates. Basic building units are isolated three-membered [Si 3O 9] rings located in layers parallel to (010). Within a single layer the rings are concentrated in strings parallel to [100]. The sequence of directedness of up ( U) or down ( D) pointing tetrahedra of a single ring is UUU or DDD, respectively. Stacking of the layers parallel to b results in the formation of a three-dimensional structure in which yttrium and sodium cations are incorporated for charge compensation. In more detail, four non-tetrahedral cation positions can be differentiated which are coordinated by 6 and 8 oxygen ligands. Refinements of the site occupancies did not reveal any indication for mixed Na-Y populations on these positions. Finally, several geometrical parameters of rings occurring in cyclo-trisilicate structures have been compiled and are discussed.
Robot-assisted vasovasostomy using a single layer anastomosis.
Marshall, Michael T; Doudt, Alexander D; Berger, Jonathan H; Auge, Brian K; Christman, Matthew S; Choe, Chong H
2017-09-01
Of all patients who have vasectomies performed in the United States, upwards of 6% will pursue a vasectomy reversal. Currently, the gold-standard reversal procedure is a microscopic vasovasostomy utilizing either a one or two-layer vasal anastomosis. Unfortunately, most urologists do not perform these procedures as they require extensive training and experience in microsurgery. The objective of our study was to evaluate the feasibility and success rate of robot-assisted vasovasostomy performed at our institution. We completed a retrospective review of our experience with vasectomy reversal utilizing the da Vinci ® Surgical System and a single layer vasal anastomosis. A successful reversal was defined as a return of sperm on semen analysis or light microscopy. Since 2009 we have completed 79 robotic vasectomy reversals, 60 of which utilized a single-layer vasal anastomosis. The average obstructive interval was 5.7 ± 2.2 years. Average operative time was 192 min. 42 patients returned for a post-operative semen evaluation at an average time of 4.3 months post-procedure revealing a success rate of 88% (37 out of 42). Post-operative semen parameters were significant for an average sperm density of 31.0 million/mL with an average motility of 29.1%. Robot-assisted vasovasostomy with a single layer anastomosis has overall success rates that are similar to that of reported microscopic vasovasostomy rates. Although more study is warranted with regard to cost, we feel as though our study demonstrates an alternative approach to vasectomy reversal that can be performed successfully by urologists trained in robotic surgery.
Impact of long-term cryopreservation on single umbilical cord blood transplantation outcomes.
Mitchell, Richard; Wagner, John E; Brunstein, Claudio G; Cao, Qing; McKenna, David H; Lund, Troy C; Verneris, Michael R
2015-01-01
Umbilical cord blood (UCB) may be collected and cryopreserved for years before use. In vitro and murine models suggest that the duration of storage does not affect UCB progenitor cell performance; however, the impact of UCB age on clinical outcomes has not been definitely defined. This study sought to determine the effect of UCB unit cryopreservation time on hematopoietic potency. We analyzed 288 single UCB units used for transplantation from 1992 to 2013, with unit cryopreservation time ranging from .08 to 11.07 years. UCB unit post-thaw characteristics were examined, including percent recovery of total nucleated cells (TNC). The number of years the UCB unit spent in cryopreservation had no impact on TNC recovery nor UCB unit post-thaw viability. Duration of cryopreservation also had no impact on neutrophil or platelet engraftment in single UCB transplantations. These results show that UCB units can undergo cryopreservation for at least 10 years with no impact on clinical outcomes. Copyright © 2015 American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.
Theoretical model of an optothermal microactuator directly driven by laser beams
NASA Astrophysics Data System (ADS)
Han, Xu; Zhang, Haijun; Xu, Rui; Wang, Shuying; Qin, Chun
2015-07-01
This paper proposes a novel method of optothermal microactuation based on single and dual laser beams (spots). The theoretical model of the optothermal temperature distribution of an expansion arm is established and simulated, indicating that the maximum temperature of the arm irradiated by dual laser spots, at the same laser power level, is much lower than that irradiated by one single spot, and thus the risk of burning out and damaging the optothermal microactuator (OTMA) can be effectively avoided. To verify the presented method, a 750 μm long OTMA with a 100 μm wide expansion arm is designed and microfabricated, and single/dual laser beams with a wavelength of 650 nm are adopted to carry out experiments. The experimental results showed that the optothermal deflection of the OTMA under the irradiation of dual laser spots is larger than that under the irradiation of a single spot with the same power, which is in accordance with theoretical prediction. This method of optothermal microactuation may expand the practical applications of microactuators, which serve as critical units in micromechanical devices and micro-opto-electro-mechanical systems (MOEMS).
Estimating food portions. Influence of unit number, meal type and energy density.
Almiron-Roig, Eva; Solis-Trapala, Ivonne; Dodd, Jessica; Jebb, Susan A
2013-12-01
Estimating how much is appropriate to consume can be difficult, especially for foods presented in multiple units, those with ambiguous energy content and for snacks. This study tested the hypothesis that the number of units (single vs. multi-unit), meal type and food energy density disrupts accurate estimates of portion size. Thirty-two healthy weight men and women attended the laboratory on 3 separate occasions to assess the number of portions contained in 33 foods or beverages of varying energy density (1.7-26.8 kJ/g). Items included 12 multi-unit and 21 single unit foods; 13 were labelled "meal", 4 "drink" and 16 "snack". Departures in portion estimates from reference amounts were analysed with negative binomial regression. Overall participants tended to underestimate the number of portions displayed. Males showed greater errors in estimation than females (p=0.01). Single unit foods and those labelled as 'meal' or 'beverage' were estimated with greater error than multi-unit and 'snack' foods (p=0.02 and p<0.001 respectively). The number of portions of high energy density foods was overestimated while the number of portions of beverages and medium energy density foods were underestimated by 30-46%. In conclusion, participants tended to underestimate the reference portion size for a range of food and beverages, especially single unit foods and foods of low energy density and, unexpectedly, overestimated the reference portion of high energy density items. There is a need for better consumer education of appropriate portion sizes to aid adherence to a healthy diet. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.
Applicability of Different Hydraulic Parameters to Describe Soil Detachment in Eroding Rills
Wirtz, Stefan; Seeger, Manuel; Zell, Andreas; Wagner, Christian; Wagner, Jean-Frank; Ries, Johannes B.
2013-01-01
This study presents the comparison of experimental results with assumptions used in numerical models. The aim of the field experiments is to test the linear relationship between different hydraulic parameters and soil detachment. For example correlations between shear stress, unit length shear force, stream power, unit stream power and effective stream power and the detachment rate does not reveal a single parameter which consistently displays the best correlation. More importantly, the best fit does not only vary from one experiment to another, but even between distinct measurement points. Different processes in rill erosion are responsible for the changing correlations. However, not all these procedures are considered in soil erosion models. Hence, hydraulic parameters alone are not sufficient to predict detachment rates. They predict the fluvial incising in the rill's bottom, but the main sediment sources are not considered sufficiently in its equations. The results of this study show that there is still a lack of understanding of the physical processes underlying soil erosion. Exerted forces, soil stability and its expression, the abstraction of the detachment and transport processes in shallow flowing water remain still subject of unclear description and dependence. PMID:23717669
Design-of-experiments to Reduce Life-cycle Costs in Combat Aircraft Inlets
NASA Technical Reports Server (NTRS)
Anderson, Bernhard H.; Baust, Henry D.; Agrell, Johan
2003-01-01
It is the purpose of this study to demonstrate the viability and economy of Design- of-Experiments (DOE), to arrive at micro-secondary flow control installation designs that achieve optimal inlet performance for different mission strategies. These statistical design concepts were used to investigate the properties of "low unit strength" micro-effector installation. "Low unit strength" micro-effectors are micro-vanes, set a very low angle-of incidence, with very long chord lengths. They are designed to influence the neat wall inlet flow over an extended streamwise distance. In this study, however, the long chord lengths were replicated by a series of short chord length effectors arranged in series over multiple bands of effectors. In order to properly evaluate the performance differences between the single band extended chord length installation designs and the segmented multiband short chord length designs, both sets of installations must be optimal. Critical to achieving optimal micro-secondary flow control installation designs is the understanding of the factor interactions that occur between the multiple bands of micro-scale vane effectors. These factor interactions are best understood and brought together in an optimal manner through a structured DOE process, or more specifically Response Surface Methods (RSM).
"To See With My Own Eyes": Experiences of Family Visits During Phase 1 Recovery.
Wendler, M Cecilia; Smith, Katherine; Ellenburg, Wanda; Gill, Rita; Anderson, Lea; Spiegel-Thayer, Kim
2017-02-01
Long separations are a characteristic of the day of surgery, keeping patients and their family members waiting and apart. At a time of high vulnerability, these separations can cause anxiety and worry. The purpose of this study was to identify the outcomes and experiences of patients and family members who engaged in a 5- to 10-minute supervised family visit during phase I postanesthesia recovery. This was a descriptive, single-group, mixed-methods study. Quantitative data, gathered on the day of surgery, was obtained from patients (vital signs, state anxiety scores) and their designated family members (state anxiety scores); satisfaction with the visit was also measured. An optional second, qualitative phase included a semi-structured interview examining the remembered experiences of patients and family members. A statistically significant drop in state anxiety was discovered after the visit, and satisfaction with the visit was exceedingly high. Qualitatively, patients and family members described their overwhelming relief to be able "to see with my own eyes" how well each was doing. This study supports that family visits in the postanesthesia care unit are safe and profoundly important as an independent nursing intervention. Recommendations include implementation of family visits during postanesthesia care unit recovery for all patients and family members who desire them. Copyright © 2016 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Liles, Kaitlin; Amundsen, Ruth; Davis, Warren; Scola, Salvatore; Tobin, Steven; McLeod, Shawn; Mannu, Sergio; Guglielmo, Corrado; Moeller, Timothy
2013-01-01
The Stratospheric Aerosol and Gas Experiment III (SAGE III) instrument is the fifth in a series of instruments developed for monitoring aerosols and gaseous constituents in the stratosphere and troposphere. SAGE III will be delivered to the International Space Station (ISS) via the SpaceX Dragon vehicle in 2015. A detailed thermal model of the SAGE III payload has been developed in Thermal Desktop (TD). Several novel methods have been implemented to facilitate efficient payload-level thermal analysis, including the use of a design of experiments (DOE) methodology to determine the worst-case orbits for SAGE III while on ISS, use of TD assemblies to move payloads from the Dragon trunk to the Enhanced Operational Transfer Platform (EOTP) to its final home on the Expedite the Processing of Experiments to Space Station (ExPRESS) Logistics Carrier (ELC)-4, incorporation of older models in varying unit sets, ability to change units easily (including hardcoded logic blocks), case-based logic to facilitate activating heaters and active elements for varying scenarios within a single model, incorporation of several coordinate frames to easily map to structural models with differing geometries and locations, and streamlined results processing using an Excel-based text file plotter developed in-house at LaRC. This document presents an overview of the SAGE III thermal model and describes the development and implementation of these efficiency-improving analysis methods.
Westad, C; Westgaard, R H; De Luca, C J
2003-01-01
The activity pattern of low-threshold human trapezius motor units was examined in response to brief, voluntary increases in contraction amplitude (‘EMG pulse’) superimposed on a constant contraction at 4–7% of the surface electromyographic (EMG) response at maximal voluntary contraction (4–7% EMGmax). EMG pulses at 15–20% EMGmax were superimposed every minute on contractions of 5, 10, or 30 min duration. A quadrifilar fine-wire electrode recorded single motor unit activity and a surface electrode recorded simultaneously the surface EMG signal. Low-threshold motor units recruited at the start of the contraction were observed to stop firing while motor units of higher recruitment threshold stayed active. Derecruitment of a motor unit coincided with the end of an EMG pulse. The lowest-threshold motor units showed only brief silent periods. Some motor units with recruitment threshold up to 5% EMGmax higher than the constant contraction level were recruited during an EMG pulse and kept firing throughout the contraction. Following an EMG pulse, there was a marked reduction in motor unit firing rates upon return of the surface EMG signal to the constant contraction level, outlasting the EMG pulse by 4 s on average. The reduction in firing rates may serve as a trigger to induce derecruitment. We speculate that the silent periods following derecruitment may be due to deactivation of non-inactivating inward current (‘plateau potentials’). The firing behaviour of trapezius motor units in these experiments may thus illustrate a mechanism and a control strategy to reduce fatigue of motor units with sustained activity patterns. PMID:14561844
ERIC Educational Resources Information Center
Beaulieu, Barbara; And Others
This unit of instruction on selection and living styles for energy conservation in single-family and multi-family housing and mobile homes was designed for use by home economics teachers in Florida high schools and by home economics extension agents as they work with their clientele. It is one of a series of 11 instructional units (see note)…
Janoschka, Tobias; Friebe, Christian; Hager, Martin D.; Martin, Norbert
2017-01-01
Abstract By combining a viologen unit and a 2,2,6,6‐tetramethylpiperidin‐1‐oxyl (TEMPO) radical in one single combi‐molecule, an artificial bipolar redox‐active material, 1‐(4‐(((1‐oxyl‐2,2,6,6‐tetramethylpiperidin‐4‐yl)oxy)carbonyl)benzyl)‐1′‐methyl‐[4,4′‐bipyridine]‐1,1′‐diium‐chloride (VIOTEMP), was created that can serve as both the anode (−0.49 V) and cathode (0.67 V vs. Ag/AgCl) in a water‐based redox‐flow battery. While it mimics the redox states of flow battery metals like vanadium, the novel aqueous electrolyte does not require strongly acidic media and is best operated at pH 4. The electrochemical properties of VIOTEMP were investigated by using cyclic voltammetry, rotating disc electrode experiments, and spectroelectrochemical methods. A redox‐flow battery was built and the suitability of the material for both electrodes was demonstrated through a polarity‐inversion experiment. Thus, an organic aqueous electrolyte system being safe in case of cross contamination is presented. PMID:28413754
Sikes, R. K.; Cleary, W. F.; Koprowski, H.; Wiktor, T. J.; Kaplan, M. M.
1971-01-01
Three series of experiments on rabies vaccines were carried out on rhesus monkeys using suckling-mouse-brain vaccine, rabbit-brain vaccine, duck-embryo vaccine, and purified, concentrated tissue-culture vaccine. The latter was prepared in a human diploid cell strain and inactivated with β-propiolactone, and consisted of tissue-culture fluid concentrated 200-fold with a final infectivity titre of 109.8 plaque-forming units per ml before inactivation. In the first two series of experiments, several vaccines were tested for relative immunogenicity on a pre-exposure basis. In the third series, a successful model was developed in which a single inoculation of the tissue-culture vaccine administered after exposure to rabies virus, with or without accompanying standard doses of antirabies serum, was evaluated as a method of prevention. A single dose of the tissue-culture vaccine protected 7 out of 8 monkeys from death by street virus. Homologous or heterologous antirabies serum alone gave poor results. The results indicate great promise for prophylaxis in man with one dose, or perhaps a few doses, of highly concentrated, purified tissue-culture vaccine. PMID:5004004
Rural nursing unit managers: education and support for the role.
Paliadelis, Penny S
2005-01-01
Nursing unit managers (NUMs) occupy the often unenviable position of first-line management in many health services in Australia. As such, their role is complex and multifaceted requiring an intertwining of their clinical and managerial responsibilities. While there is an abundance of studies that explore and describe the various management roles in many professions and industries, little is known about the experiences of nurses as managers, particularly in rural settings. This article focuses on the education and support needs of rural nursing unit managers. A qualitative study design was used to explore the stories of a number of nursing unit managers in rural New South Wales, Australia. Data was collected using semi-structured individual interviews. Data was analysed using a voice-relational method as a framework for more clearly hearing the voices of participants. This method of data analysis is particularly useful for hearing from those who do not usually have a 'strong' voice, for gaining an understanding of the context of the interviews, and for acknowledging the role of the researcher in the research process. All NUMs employed in a single regional health authority in rural Australia were invited to participate. Out of 42 NUMs in the region, 20 agreed to be interviewed. Nursing unit managers were asked to reflect on their experiences prior to and during the early days within the position. In summary, all the NUMs: believed they were promoted because of their clinical expertise; felt unprepared for the managerial and administrative aspects of their role; continued to identify as nurses rather than as managers; found the role isolated them from their former peer group. Those employed in small facilities had limited opportunities for education and peer support. Based on the NUMs' experiences and suggestions, the following information would have helped them to cope with the demands of their new role: information and discussions about the role expectations of first-line manager, from both an employee and employer perspective; human resource and financial management skill development; leadership skills; negotiation and conflict resolution; a clear and realistic role description.
Mandal, Soumit Sankar; Merz, Dale R; Buchsteiner, Maximilian; Dima, Ruxandra I; Rief, Matthias; Žoldák, Gabriel
2017-06-06
Owing to the cooperativity of protein structures, it is often almost impossible to identify independent subunits, flexible regions, or hinges simply by visual inspection of static snapshots. Here, we use single-molecule force experiments and simulations to apply tension across the substrate binding domain (SBD) of heat shock protein 70 (Hsp70) to pinpoint mechanical units and flexible hinges. The SBD consists of two nanomechanical units matching 3D structural parts, called the α- and β-subdomain. We identified a flexible region within the rigid β-subdomain that gives way under load, thus opening up the α/β interface. In exactly this region, structural changes occur in the ATP-induced opening of Hsp70 to allow substrate exchange. Our results show that the SBD's ability to undergo large conformational changes is already encoded by passive mechanics of the individual elements.
Mandal, Soumit Sankar; Buchsteiner, Maximilian; Dima, Ruxandra I.; Rief, Matthias; Žoldák, Gabriel
2017-01-01
Owing to the cooperativity of protein structures, it is often almost impossible to identify independent subunits, flexible regions, or hinges simply by visual inspection of static snapshots. Here, we use single-molecule force experiments and simulations to apply tension across the substrate binding domain (SBD) of heat shock protein 70 (Hsp70) to pinpoint mechanical units and flexible hinges. The SBD consists of two nanomechanical units matching 3D structural parts, called the α- and β-subdomain. We identified a flexible region within the rigid β-subdomain that gives way under load, thus opening up the α/β interface. In exactly this region, structural changes occur in the ATP-induced opening of Hsp70 to allow substrate exchange. Our results show that the SBD’s ability to undergo large conformational changes is already encoded by passive mechanics of the individual elements. PMID:28533394
Power in the loop real time simulation platform for renewable energy generation
NASA Astrophysics Data System (ADS)
Li, Yang; Shi, Wenhui; Zhang, Xing; He, Guoqing
2018-02-01
Nowadays, a large scale of renewable energy sources has been connecting to power system and the real time simulation platform is widely used to carry out research on integration control algorithm, power system stability etc. Compared to traditional pure digital simulation and hardware in the loop simulation, power in the loop simulation has higher accuracy and degree of reliability. In this paper, a power in the loop analog digital hybrid simulation platform has been built and it can be used not only for the single generation unit connecting to grid, but also for multiple new energy generation units connecting to grid. A wind generator inertia control experiment was carried out on the platform. The structure of the inertia control platform was researched and the results verify that the platform is up to need for renewable power in the loop real time simulation.
Warad, Deepti; Rao, Amulya Nageswara; Mullikin, Trey; Graner, Kevin; Shaughnessy, William J; Pruthi, Rajiv K; Rodriguez, Vilmarie
2015-08-01
Dalteparin is a commonly used low molecular weight heparin (LMWH) with extensive safety data in adults. With distinct advantages of once daily dosing and relative safety in renal impairment, it has been used off-label in pediatric practice; however, age-based dosing guidelines, safety and efficacy data in children are evolving. To report our institutional experience with the use of dalteparin in the treatment and prophylaxis of venous thromboembolism (VTE) in pediatric patients. Retrospective chart review of all children (0-18years) that received dalteparin from December 1, 2000 through December 31, 2011. Doses per unit body weight per day (units/kg/day) were calculated for age-based group comparisons. Of 166 patients identified, 116 (70%) received prophylactic doses while 50 (30%) received therapeutic doses of dalteparin. Infants (<1year) required significantly higher weight-based dosing to achieve therapeutic anti-Xa levels compared to children (1-10years) or adolescents (>10-18years) (mean dose units/kg/day; 396.6 versus 236.7 and 178.8 respectively, p<0.0001). Overall response rate, including complete and partial thrombus resolution, was 83%. Bleeding complications were minor and the rates were similar in therapeutic and prophylaxis patients. No significant differences in dosing or bleeding events were noted based on obesity or malignancy. In our experience, dalteparin is effective for prophylaxis and therapy of VTE in pediatric patients. Dosing should be customized in an age-based manner with close monitoring of anti-Xa activity in order to achieve optimal levels, prevent bleeding complications, and to allow full benefit of prevention or therapy of thrombotic complications. Copyright © 2015 Elsevier Ltd. All rights reserved.
Single-unit muscle sympathetic nervous activity and its relation to cardiac noradrenaline spillover
Lambert, Elisabeth A; Schlaich, Markus P; Dawood, Tye; Sari, Carolina; Chopra, Reena; Barton, David A; Kaye, David M; Elam, Mikael; Esler, Murray D; Lambert, Gavin W
2011-01-01
Abstract Recent work using single-unit sympathetic nerve recording techniques has demonstrated aberrations in the firing pattern of sympathetic nerves in a variety of patient groups. We sought to examine whether nerve firing pattern is associated with increased noradrenaline release. Using single-unit muscle sympathetic nerve recording techniques coupled with direct cardiac catheterisation and noradrenaline isotope dilution methodology we examined the relationship between single-unit firing patterns and cardiac and whole body noradrenaline spillover to plasma. Participants comprised patients with hypertension (n = 6), depression (n = 7) and panic disorder (n = 9) who were drawn from our ongoing studies. The patient groups examined did not differ in their single-unit muscle sympathetic nerve firing characteristics nor in the rate of spillover of noradrenaline to plasma from the heart. The median incidence of multiple spikes per beat was 9%. Patients were stratified according to the firing pattern: low level of incidence (less than 9% incidence of multiple spikes per beat) and high level of incidence (greater than 9% incidence of multiple spikes per beat). High incidence of multiple spikes within a cardiac cycle was associated with higher firing rates (P < 0.0001) and increased probability of firing (P < 0.0001). Whole body noradrenaline spillover to plasma and (multi-unit) muscle sympathetic nerve activity in subjects with low incidence of multiple spikes was not different to that of those with high incidence of multiple spikes. In those with high incidence of multiple spikes there occurred a parallel activation of the sympathetic outflow to the heart, with cardiac noradrenaline spillover to plasma being two times that of subjects with low nerve firing rates (11.0 ± 1.5 vs. 22.0 ± 4.5 ng min−1, P < 0.05). This study indicates that multiple within-burst firing and increased single-unit firing rates of the sympathetic outflow to the skeletal muscle vasculature is associated with high cardiac noradrenaline spillover. PMID:21486790
Work environment for Chinese nurses in different types of ICUs: a multisite cross-sectional survey.
Bai, Jinbing; Zhang, Qing; Wang, Ying; Yu, Li-Ping; Pei, Xian-Bo; Cheng, Lei; Hsu, Lily
2015-05-01
To investigate the current nurse work environment, levels of job satisfaction and quality of patient care, and to identify intensive care units with a healthier work environment in mainland China. A healthy work environment is closely related to a higher nurse job satisfaction and a better patient care quality. The work environment has not been extensively explored among Chinese intensive care unit nurses. The Chinese version of the Essentials of Magnetism II was used to measure the nurse work environment and another two 0-10 single-item scales were used to assess nurses' overall job satisfaction and nurse-assessed quality of care. The study found that the eight essentials of Chinese version of the Essentials of Magnetism II were significantly correlated with each other and also correlated with overall job satisfaction and quality of care. Nurses from medical intensive care units had a healthier work environment with higher scores of overall job satisfaction and quality of care than other intensive care units, while surgical intensive care units showed the least healthy work environment with the lowest overall job satisfaction and quality of care scores identified. The essentials of Chinese version of the Essentials of Magnetism II, overall job satisfaction and quality of care were also correlated with nurses' work experience and their education level. Nurse administrators and health policy-makers should establish a healthy work environment for intensive care units nurses, especially for those from surgical intensive care units. © 2014 John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Nakashima, T.; Fox, S. W.
1981-01-01
The synthesis of peptides from individual amino acids or pairs of amino acids and ATP in the presence of catalysis by nucleoproteinoid microparticles is investigated. Experiments were performed with suspensions formed from the condensation of lysine-rich and acidic proteinoids with polyadenylic acid, to which were added glycine, phenylalanine, proline, lysine or glycine-phenylalanine mixtures, and ATP either at once or serially. Peptide yields are found to be greatest for equal amounts of acidic and basic proteinoids. The addition of imidazole is found to alter the preference of glycine-phenylalanine mixtures to form mixed heteropeptides rather than homopeptides. A rapid ATP decay in the peptide synthesis reaction is observed, and a greater yield is obtained for repeated small additions than for a single addition of ATP. The experimental system has properties similar to modern cells, and represents an organizational unit ready for the evolution of associated biochemical pathways.
Fennell, John F.; Hamaguchi, Hitoshi; Yoon, Bora; Swager, Timothy M.
2017-01-01
Chemical warfare agents (CWA) continue to present a threat to civilian populations and military personnel in operational areas all over the world. Reliable measurements of CWAs are critical to contamination detection, avoidance, and remediation. The current deployed systems in United States and foreign militaries, as well as those in the private sector offer accurate detection of CWAs, but are still limited by size, portability and fabrication cost. Herein, we report a chemiresistive CWA sensor using single-walled carbon nanotubes (SWCNTs) wrapped with poly(3,4-ethylenedioxythiophene) (PEDOT) derivatives. We demonstrate that a pendant hexafluoroisopropanol group on the polymer that enhances sensitivity to a nerve agent mimic, dimethyl methylphosphonate, in both nitrogen and air environments to concentrations as low as 5 ppm and 11 ppm, respectively. Additionally, these PEDOT/SWCNT derivative sensor systems experience negligible device performance over the course of two weeks under ambient conditions. PMID:28452929
Fennell, John F; Hamaguchi, Hitoshi; Yoon, Bora; Swager, Timothy M
2017-04-28
Chemical warfare agents (CWA) continue to present a threat to civilian populations and military personnel in operational areas all over the world. Reliable measurements of CWAs are critical to contamination detection, avoidance, and remediation. The current deployed systems in United States and foreign militaries, as well as those in the private sector offer accurate detection of CWAs, but are still limited by size, portability and fabrication cost. Herein, we report a chemiresistive CWA sensor using single-walled carbon nanotubes (SWCNTs) wrapped with poly(3,4-ethylenedioxythiophene) (PEDOT) derivatives. We demonstrate that a pendant hexafluoroisopropanol group on the polymer that enhances sensitivity to a nerve agent mimic, dimethyl methylphosphonate, in both nitrogen and air environments to concentrations as low as 5 ppm and 11 ppm, respectively. Additionally, these PEDOT/SWCNT derivative sensor systems experience negligible device performance over the course of two weeks under ambient conditions.
A computational substrate for incentive salience.
McClure, Samuel M; Daw, Nathaniel D; Montague, P Read
2003-08-01
Theories of dopamine function are at a crossroads. Computational models derived from single-unit recordings capture changes in dopaminergic neuron firing rate as a prediction error signal. These models employ the prediction error signal in two roles: learning to predict future rewarding events and biasing action choice. Conversely, pharmacological inhibition or lesion of dopaminergic neuron function diminishes the ability of an animal to motivate behaviors directed at acquiring rewards. These lesion experiments have raised the possibility that dopamine release encodes a measure of the incentive value of a contemplated behavioral act. The most complete psychological idea that captures this notion frames the dopamine signal as carrying 'incentive salience'. On the surface, these two competing accounts of dopamine function seem incommensurate. To the contrary, we demonstrate that both of these functions can be captured in a single computational model of the involvement of dopamine in reward prediction for the purpose of reward seeking.
Orbital effect of the magnetic field in dynamical mean-field theory
NASA Astrophysics Data System (ADS)
Acheche, S.; Arsenault, L.-F.; Tremblay, A.-M. S.
2017-12-01
The availability of large magnetic fields at international facilities and of simulated magnetic fields that can reach the flux-quantum-per-unit-area level in cold atoms calls for systematic studies of orbital effects of the magnetic field on the self-energy of interacting systems. Here we demonstrate theoretically that orbital effects of magnetic fields can be treated within single-site dynamical mean-field theory with a translationally invariant quantum impurity problem. As an example, we study the one-band Hubbard model on the square lattice using iterated perturbation theory as an impurity solver. We recover the expected quantum oscillations in the scattering rate, and we show that the magnetic fields allow the interaction-induced effective mass to be measured through the single-particle density of states accessible in tunneling experiments. The orbital effect of magnetic fields on scattering becomes particularly important in the Hofstadter butterfly regime.
Rogers, S; Silver, S M; Goss, J; Obenchain, J; Willis, A; Whitney, R L
1999-01-01
This report summarizes data gathered thus far from an ongoing study. Two groups (total N = 12) of Vietnam War veterans diagnosed with Posttraumatic Stress Disorder (PTSD) received a single session of exposure or Eye Movement Desensitization and Reprocessing (EMDR) focusing on the veterans' most distressing war experience. Group assignment was random, treatment providers were blind to assessment data, and the pre- and posttreatment assessor was blind to treatment assignment. Both groups showed improvement on the Impact of Event Scale. EMDR treatment resulted in greater positive changes in within-session Subjective Units of Discomfort levels and on self-monitored severity of intrusive recollection. A trend toward decreased heart rate reactivity was observed in both groups. Results must be considered carefully due to the small number of subjects used in the study.
Julian, Samuel; Burnham, Carey-Ann D.; Sellenriek, Patricia; Shannon, William D.; Hamvas, Aaron; Tarr, Phillip I.; Warner, Barbara B.
2016-01-01
Objectives Infections cause significant morbidity and mortality in neonatal intensive care units (NICUs). The association between nursery design and nosocomial infections has not been delineated. We hypothesized that rates of colonization by methicillin-resistant Staphylococcus aureus (MRSA), late-onset sepsis, and mortality are reduced in single-patient rooms. Design Retrospective cohort study. Setting NICU in a tertiary referral center. Methods Our NICU is organized into single-patient and open-unit rooms. Clinical datasets including bed location and microbiology results were examined over a 29-month period. Differences in outcomes between bed configurations were determined by Chi-square and Cox regression. Patients All NICU patients. Results Among 1823 patients representing 55,166 patient-days, single-patient and open-unit models had similar incidences of MRSA colonization and MRSA colonization-free survival times. Average daily census was associated with MRSA colonization rates only in single-patient rooms (hazard ratio 1.31, p=0.039), while hand hygiene compliance on room entry and exit was associated with lower colonization rates independent of bed configuration (hazard ratios 0.834 and 0.719 per 1% higher compliance, respectively). Late-onset sepsis rates were similar in single-patient and open-unit models as were sepsis-free survival and the combined outcome of sepsis or death. After controlling for demographic, clinical and unit-based variables, multivariate Cox regression demonstrated that bed configuration had no effect on MRSA colonization, late-onset sepsis, or mortality. Conclusions MRSA colonization rate was impacted by hand hygiene compliance, regardless of room configuration, while average daily census only affected infants in single-patient rooms. Single-patient rooms did not reduce the rates of MRSA colonization, late-onset sepsis or death. PMID:26108888
Multidose Botulinum Toxin A for Intralaryngeal Injection: A Cost Analysis.
Gilbert, Mark R; Young, VyVy N; Smith, Libby J; Rosen, Clark A
2018-01-04
Botulinum toxin A (BtxA) injection is the mainstay treatment for laryngeal dystonias. BtxA product labeling states that reconstituted toxin should be used within 4 hours on a single patient despite several studies that have demonstrated multidose BtxA to be safe and effective. Many insurance carriers mandate the use of an outside pharmacy which necessitates a single-use approach. This study compares the cost savings of multidose BtxA for laryngeal dystonia compared to single-use. This is a retrospective review and projected cost savings analysis. Records and billing information were reviewed for patients receiving BtxA for intralaryngeal injection at a single laryngology division in 2015. Inclusion criteria included CPT 64617 or J0585; exclusion criteria included CPT 64616. The price of BtxA 100 unit vial for calculation was $670. A total of 142 patients were seen for intralaryngeal BtxA injection resulting in 337 visits over 1 year. The average BtxA dose per visit was 2.86 units with an average of 3.06 procedure visits per year. The calculated cost of BtxA treatment using a single vial approach was found to be $2,050 per patient per year. If billed instead for $7/unit with 5 units wastage charge per visit, the yearly per patient charge is $168. Single vial-use of BtxA injection thus represents a 1,118% price increase versus multidose use. When estimated for yearly prevalence of spasmodic dysphonia, multidose BtxA use would save almost $100 million annually. Multidose botulinum toxin A application utilizing per unit billing is significantly less expensive than per single-use vial billing and would save the health-care system significant amount of money without any sacrifice in safety or effectiveness. Copyright © 2018. Published by Elsevier Inc.
Gschwind, Michael K [Chappaqua, NY
2011-03-01
Mechanisms for implementing a floating point only single instruction multiple data instruction set architecture are provided. A processor is provided that comprises an issue unit, an execution unit coupled to the issue unit, and a vector register file coupled to the execution unit. The execution unit has logic that implements a floating point (FP) only single instruction multiple data (SIMD) instruction set architecture (ISA). The floating point vector registers of the vector register file store both scalar and floating point values as vectors having a plurality of vector elements. The processor may be part of a data processing system.
45 CFR 302.12 - Single and separate organizational unit.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 45 Public Welfare 2 2010-10-01 2010-10-01 false Single and separate organizational unit. 302.12 Section 302.12 Public Welfare Regulations Relating to Public Welfare OFFICE OF CHILD SUPPORT ENFORCEMENT (CHILD SUPPORT ENFORCEMENT PROGRAM), ADMINISTRATION FOR CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND...
20 CFR 668.120 - How must INA programs be administered?
Code of Federal Regulations, 2010 CFR
2010-04-01
... Federal commitment to support the growth and development of Native American people and communities as... administer INA programs through a single organizational unit and consistent with the requirements in section...) within the Employment and Training Administration (ETA) as this single organizational unit required by...
Studies on system and measuring method of far-field beam divergency in near field by Ronchi ruling
NASA Astrophysics Data System (ADS)
Zhou, Chenbo; Yang, Li; Ma, Wenli; Yan, Peiying; Fan, Tianquan; He, Shangfeng
1996-10-01
Up to now, as large as seven times of Rayleigh-range or more is needed in measuring the far-field Gaussian beam divergency. This method is very inconvenient for the determination of the output beam divergency of the industrial product such as He-Ne lasers and the measuring unit will occupy a large space. The measurement and the measuring accuracy will be greatly influenced by the environment. Application of the Ronchi ruling to the measurement of far-field divergency of Gaussian beam in near-field is analyzed in the paper. The theoretical research and the experiments show that this measuring method is convenient in industrial application. The measuring system consists of a precision mechanical unit which scans Gaussian beam with a microdisplaced Ronchi ruling, a signal sampling system, a single-chip microcomputer data processing system and an electronic unit with microprinter output. The characteristics of the system is stable and the repeatability errors of the system are low. The spot size and far-field divergency of visible Gaussian laser beam can be measured with the system.
Emergency recompression: clinical audit of service delivery at a national level.
Ross, John As; Sayer, Martin Dj
2009-03-01
Clinical audit is an essential element to the maintenance or improvement of delivery of any medical service. During the development phase of a National Recompression Registration Service for Scotland, clinical audit was initiated to provide a standardised tool to monitor the quality of outcome with respect to the severity of presentation. A functional audit process was an essential consideration for planned future measurement of treatment efficacy at local (single hyperbaric unit) and national (multiple hyperbaric units) scales. The audit process was designed to be undemanding, robust and informative, irrespective of the experience of treatment centre and of the clinician in charge of treatment. The clinical records from 104 cases of divers with decompression illness were used to derive and evaluate measures of severity and clinical outcome that could be used for audit and quality assurance. The various measures of disease severity were examined against clinical outcome and days spent in care after admission to a hyperbaric unit. An initial version of the clinical audit format that was developed from this process is presented.
Ferrari, Adriano; Manca, Mario; Tugnoli, Valeria
2018-01-01
Summary Three different type A botulinum neurotoxins (BoNTAs) — onabotulinumtoxinA, abobotulinumtoxinA and incobotulinumtoxinA) — are currently marketed in Europe to treat several conditions. Differences between BoNTA preparations, which depend on their specific biotypes and manufacturing processes, lead to clinically relevant pharmacotherapeutic dissimilarities. All three available products are separately recognized and reviewed in American Academy of Neurology guidelines. The neurotoxin load/100U is likewise different among the different BoNTAs, with the result that the specific potency of the 150kD BoNTA neurotoxin is calculated as 137 units/ng for onabotulinumtoxinA, 154 units/ng for abobotulinumtoxinA, and 227 units/ng for incobotulinumtoxinA. It is important for clinicians to have all three BoNTAs available in order to choose the most suitable preparation for the specific indication in the single patient. Commercially available BoNTAs must be recognized as different from one another, and therefore as non-interchangeable. The essential experience of the clinician is of the utmost importance in choosing the most appropriate treatment. PMID:29633692
Leveling up and down: the experiences of benign and malicious envy.
van de Ven, Niels; Zeelenberg, Marcel; Pieters, Rik
2009-06-01
Envy is the painful emotion caused by the good fortune of others. This research empirically supports the distinction between two qualitatively different types of envy, namely benign and malicious envy. It reveals that the experience of benign envy leads to a moving-up motivation aimed at improving one's own position, whereas the experience of malicious envy leads to a pulling-down motivation aimed at damaging the position of the superior other. Study 1 used guided recall of the two envy types in a culture (the Netherlands) that has separate words for benign and malicious envy. Analyses of the experiential content of these emotions found the predicted differences. Study 2 and 3 used one sample from the United States and one from Spain, respectively, where a single word exists for both envy types. A latent class analysis based on the experiential content of envy confirmed the existence of separate experiences of benign and malicious envy in both these cultures as well. The authors discuss the implications of distinguishing the two envy types for theories of cooperation, group performance, and Schadenfreude.
Research on Supersonic Inlet Bleed
NASA Technical Reports Server (NTRS)
Davis, David O.; Vyas, Manan A.; Slater, John W.
2012-01-01
Phase I data results of the Fundamental Inlet Bleed Experiments project at NASA Glenn Research Center (GRC) are presented which include flow coefficient results for two single-hole boundary-layer bleed configurations. The bleed configurations tested are round holes at inclination angles of 90deg and 20deg both having length-to-diameter ratios of 2.0. Results were obtained at freestream Mach numbers of 1.33, 1.62, 1.98, 2.46, and 2.92 and unit Reynolds numbers of 0.984, 1.89, and 2.46 10(exp 7)/m. Approach boundary-layer data are presented for each flow condition and the flow coefficient results are compared to existing multi-hole data obtained under similar conditions. For the 90deg hole, the single and multi-hole distributions agree fairly well with the exception that under supercritical operation, the multi-hole data chokes at higher flow coefficient levels. This behavior is also observed for the 20deg hole but to a lesser extent. The 20deg hole also shows a markedly different characteristic at subcritical operation. Also presented are preliminary results of a Computational Fluid Dynamics (CFD) analysis of both configurations at the Mach 1.33 and a unit Reynolds number of 2.46 10(exp 7)/m. Comparison of the results shows the agreement to be very good.
NASA Technical Reports Server (NTRS)
Ippolito, L. J. (Compiler)
1972-01-01
Papers are reported from the Special Session on Earth-Satellite Propagation Above 10 GHz, presented at The 1972 Spring Meeting of the United States National Committee, International Union of Radio Science, April 1972, Washington, D. C. This session was devoted to propagation measurements associated with the Applications Technology Satellite (ATS-5), which provided the first operational earth-space links at frequencies above 15 GHz. A comprehensive summary is presented of the major results of the ATS-5 experiment measurements and related radiometric, radar and meteorological studies. The papers are organized around seven selected areas of interest, with the results of the various investigators combined into a single paper presented by a principal author for that area. A comprehensive report is provided on the results of the ATS-5 satellite to earth transmissions. A complete list of published reports and presentations related to the ATS-5 Millimeter Wave Experiment is included.
The experiences of patients and carers living with multimorbid, non-communicable diseases
Leeder, Stephen R; Jowsey, Tanisha; McNab, Justin W
2018-01-01
Non-communicable diseases (NCDs) are increasing in prevalence and straining health systems globally. This creates a so-called 'burden of disease', which can be traced in terms of fiscal health system matters and in terms of quality of life and lived experiences of people with NCDs. The United Nations has called for a global agenda to manage NCDs and reduce their burden. The purpose of this article is to summarise key findings from the Serious and Continuing Illness Policy and Practice Study concerning patients’ and carers’ experiences of multimorbid NCDs in Australia. We focus on the relevance of findings for policy and general practitioners in Australia. We suggest that a complex multimorbidity policy is needed to contextualise and guide single-illness NCD policies. Our research suggests that specialist NCD nurses and allied health professionals could have important roles in improving care coordination between general practices and community health centres.
Peaceful play yoga: serenity and balance for children with cancer and their parents.
Thygeson, Megan V; Hooke, Mary C; Clapsaddle, Jeanine; Robbins, Angela; Moquist, Kristin
2010-01-01
Children with a cancer diagnosis experience symptom distress, including anxiety, because of the disease and its treatment. Parents experience stress and anxiety because of the uncertainty of the disease as well as the suffering of their children. Yoga is a complementary intervention that has physiological and psychological benefits in healthy children and healthy and chronically ill adults. On an inpatient hematology/oncology unit, 11 children aged 6 to 12 years, 5 adolescents aged 13 to 18 years, and 33 parents participated in a single yoga session tailored to the needs and abilities of the patients and parents. Sense of well-being pre- and postclass was measured with the Spielberger State Anxiety Scale. Children had normal anxiety scores preclass that did not change. Adolescents and parents experienced significant decreases in anxiety scores, and all cohorts gave positive feedback about the experience. The authors conclude that yoga is a feasible intervention for this population and is beneficial to adolescents and parents.
NASA Astrophysics Data System (ADS)
Magyar, Andrew
The recent discovery of cells that respond to purely conceptual features of the environment (particular people, landmarks, objects, etc) in the human medial temporal lobe (MTL), has raised many questions about the nature of the neural code in humans. The goal of this dissertation is to develop a novel statistical method based upon maximum likelihood regression which will then be applied to these experiments in order to produce a quantitative description of the coding properties of the human MTL. In general, the method is applicable to any experiments in which a sequence of stimuli are presented to an organism while the binary responses of a large number of cells are recorded in parallel. The central concept underlying the approach is the total probability that a neuron responds to a random stimulus, called the neuronal sparsity. The model then estimates the distribution of response probabilities across the population of cells. Applying the method to single-unit recordings from the human medial temporal lobe, estimates of the sparsity distributions are acquired in four regions: the hippocampus, the entorhinal cortex, the amygdala, and the parahippocampal cortex. The resulting distributions are found to be sparse (large fraction of cells with a low response probability) and highly non-uniform, with a large proportion of ultra-sparse neurons that possess a very low response probability, and a smaller population of cells which respond much more frequently. Rammifications of the results are discussed in relation to the sparse coding hypothesis, and comparisons are made between the statistics of the human medial temporal lobe cells and place cells observed in the rodent hippocampus.
Dual Fan Separator within the Universal Waste Management System
NASA Technical Reports Server (NTRS)
Stapleton, Tom; Converse, Dave; Broyan, James Lee, Jr.
2014-01-01
Since NASA's new spacecraft in development for both LEO and Deep Space capability have considerable crew volume reduction in comparison to the Space Shuttle, it is clear that NASA requires a smaller and less expensive commode. The UTAS Universal Waste Management System (UWMS) was designed to address these new constraints, resulting in an 80% volume reduction in the cabin while enhancing performance. Whereas all of the current space commodes use air flow to capture both urine and feces and separate air from the captured air/urine mixture, the UWMS commode and urine fans and the urine separator were combined into a single unit. This unit enables use of a single motor and motor controller, which provides considerable packaging and weight efficiency. In some of the intended platform applications for the UWMS, the urine is pumped to a water reclamation system. The ISS Urine Processor Assembly (UPA) system requires delivered urine to include less than 0.25% air inclusion. Air inclusion in centrifugal urine separators is greatly dependent on its rotational speed. To satisfy this requirement, a gear reducer was included, allowing the fans to rotate at a much higher speed than the separator. This new design, the Dual Fan Separator (DFS) has been designed, prototyped and tested. This paper will outline the studies and analysis performed to develop the design configuration for testing. The studies included a configuration trade study, dynamic stability analysis of the rotating bodies and a performance analysis of included labyrinth seals. NASA is considereing a program to fly the UWMS aboard the ISS as a flight experiment. The goal of the design activity is to elevate the Technical Readiness Level (TRL) of the Dual Fan Separator and determine if the concept is ready to be included in flight experiment deliverable.
The Community Mentoring REU: A Novel Paradigm for Research Experiences for Undergraduates Programs
NASA Astrophysics Data System (ADS)
Kobulnicky, Henry; Maierhofer, Lara; Kobulnicky, Carol; Dale, Daniel A.
2018-01-01
Research Experience for Undergraduates programs were conceived to promote entry of college students into STEM disciplines. Evidence suggests that participating in REUs increases interest in STEM, conveys skills leading to STEM jobs and graduate study, increases science self-efficacy, builds professional networks for young scientists, and cultivates identity as a scientist. Nevertheless, the factors that mediate desired outcomes are still poorly understood, and persistence of negative mentoring experiences among REU participants motivates the design and study of novel approaches to preparing future STEM professionals. During five summers spanning 2012-2016 we implemented a "Community Mentoring" paradigm at the University of Wyoming's 10-week Astronomy REU program. In contrast to "traditional model (TM)" REUs that pair a single senior scientist mentor with a single junior mentee, community mentoring (CM) unites 6-8 undergraduates with 3-5 faculty (perhaps assisted by a graduate student or postdoc) on a collaborative team addressing a single science goal. In CM, students have access to a pool of mentors and a peer group reading the same literature, working in a common location, sharing equipment (in this case the WIRO 2.3 meter telescope), sharing data, and learning the same analysis skills. The community interacts daily, modeling the highly collaborative nature of modern scientific teams. Our study used an electronic survey consisting of 24 questions to compare a cohort of 28 CM students to a national control group of 77 students who conducted REUs elsewhere during the same period, typically under the TM. CM students report a significantly higher level of "learning from their peers", "learning to work on a science team", and "sense of community" compared to the TM cohort. The CM cohort also reports a higher overall level of satisfaction with the REU and a lower level of negative experiences, such as finding it difficult to get time with a mentor. This talk will review other lessons learned in five years of community mentoring as it describes an alternative paradigm for REUs.
School closures during the 2009 influenza pandemic: national and local experiences
2014-01-01
Background School closure is a non-pharmaceutical intervention that was considered in many national pandemic plans developed prior to the start of the influenza A(H1N1)pdm09 pandemic, and received considerable attention during the event. Here, we retrospectively review and compare national and local experiences with school closures in several countries during the A(H1N1)pdm09 pandemic. Our intention is not to make a systematic review of country experiences; rather, it is to present the diversity of school closure experiences and provide examples from national and local perspectives. Methods Data were gathered during and following a meeting, organized by the European Centres for Disease Control, on school closures held in October 2010 in Stockholm, Sweden. A standard data collection form was developed and sent to all participants. The twelve participating countries and administrative regions (Bulgaria, China, France, Hong Kong Special Administrative Region (SAR), Italy, Japan, New Zealand, Serbia, South Africa, Thailand, United Kingdom, and United States) provided data. Results Our review highlights the very diverse national and local experiences on school closures during the A(H1N1)pdm09 pandemic. The processes including who was in charge of making recommendations and who was in charge of making the decision to close, the school-based control strategies, the extent of school closures, the public health tradition of responses and expectations on school closure varied greatly between countries. Our review also discusses the many challenges associated with the implementation of this intervention and makes recommendations for further practical work in this area. Conclusions The single most important factor to explain differences observed between countries may have been the different public health practises and public expectations concerning school closures and influenza in the selected countries. PMID:24739814
Diversity of coding profiles of mechanoreceptors in glabrous skin of kittens.
Gibson, J M; Beitel, R E; Welker, W
1975-03-21
We examined stimulul-response (S-R) profiles of 35 single mechanoreceptive afferent units having small receptive fields in glabrous forepaw skin of 24 anesthetized domestic kittens. Single unit activity was recorded with tungsten microelectrodes from cervical dorsal root ganglia. The study was designed to be as quantitatively descriptive as possible. We indented each unit's receptive field with a broad battery of simple, carefully controlled stimuli whose major parameters, including amplitude, velocity, acceleration, duration, and interstimulus interval were systematically varied. Stimuli were delivered by a small probe driven by a feedback-controlled axial displacement generator. Single unit discharge data were analyzed by a variety of direct and derived measures including dot patterns, peristimulus histograms, instantaneous and mean instantaneous firing rates, tuning curves, thresholds for amplitude and velocity, adaptation rates, dynamic and static sensitivities, and others. We found that with respect to any of the S-R transactions examined, the properties of our sample of units were continuously and broadly distributed. Any one unit might exhibit either a slow or rapid rate of adaptation, or might superficially appear to preferentially code a single stimulus parameter such as amplitude or velocity. But when the entire range of responsiveness of units to the entire stimulus battery was surveyed by a variety of analytic techniques, we were unable to find any justifiable basis for designation of discrete categories of S-R profiles. Intermediate response types were always found, and in general, all units were both broadly tuned and capable of responding to integrals of several stimulus parameters, our data argue against the usefulness of evaluating a unit's S-R coding capabilities by means of a limited ste of stimulation of response analysis procedures.
DOT National Transportation Integrated Search
2009-10-01
This report presents the findings of a comprehensive engineering analysis of electronic stability control (ESC) and roll stability control (RSC) systems for single-unit medium and heavy trucks and large-platform buses. This report details the applica...
Halvorsen, John G
2008-05-01
Primary care as an academic discipline and key component of the U.S. health care system faces a threatened future, despite numerous studies in the United States and cross-nationally that substantiate its health-promoting benefits. The United States remains the only Western industrialized nation that delivers primary care through three major disciplines rather than as a single specialty. This fragmented model may contribute to the fact that the United States does not have a primary-care-based health care system and that the U.S. population demonstrates poorer health outcomes than do those countries whose health systems are based on primary care and managed by a single primary care specialty. Fragmentation also creates confusion about primary care's identity, diminishes its influence because it does not speak with a common voice, and creates competition for academic and professional status, resources, curricular priority, research and training program funding, patients, and reimbursement. A large, single-specialty body of primary physicians could eliminate much duplication and competition and demonstrate greater political influence with academia, government agencies, insurers, and corporate America. A single specialty that incorporates the strengths of the three primary care disciplines would expand the clinical scope of primary care and could serve as a potent enabling force to lead health system reform. It would also produce measurable benefits for medical student and graduate medical education, health system design and service delivery, and primary care research. The author outlines a plan of action, involving all stakeholders, to initiate and achieve the single-specialty goal.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davenport, Michael; Petti, D. A.; Palmer, Joe
2016-11-01
The United States Department of Energy’s Advanced Reactor Technologies (ART) Advanced Gas Reactor (AGR) Fuel Development and Qualification Program is irradiating up to seven low enriched uranium (LEU) tri-isotopic (TRISO) particle fuel (in compact form) experiments in the Advanced Test Reactor (ATR) located at the Idaho National Laboratory (INL). These irradiations and fuel development are being accomplished to support development of the next generation reactors in the United States. The experiments will be irradiated over the next several years to demonstrate and qualify new TRISO coated particle fuel for use in high temperature gas reactors. The goals of the experimentsmore » are to provide irradiation performance data to support fuel process development, to qualify fuel for normal operating conditions, to support development and validation of fuel performance and fission product transport models and codes, and to provide irradiated fuel and materials for post irradiation examination (PIE) and safety testing. The experiments, which will each consist of several independent capsules, will be irradiated in an inert sweep gas atmosphere with individual on-line temperature monitoring and control of each capsule. The sweep gas will also have on-line fission product monitoring on its effluent to track performance of the fuel in each individual capsule during irradiation. The first experiment (designated AGR-1) started irradiation in December 2006 and was completed in November 2009. The second experiment (AGR-2) started irradiation in June 2010 and completed in October 2013. The third and fourth experiments have been combined into a single experiment designated (AGR-3/4), which started its irradiation in December 2011 and completed in April 2014. Since the purpose of this experiment was to provide data on fission product migration and retention in the NGNP reactor, the design of this experiment was significantly different from the first two experiments, though the control and monitoring systems are very similar. The final experiment, AGR-5/6/7, is scheduled to begin irradiation in early summer 2017.« less
Janssen, Patricia A; Keen, Lois; Soolsma, Jetty; Seymour, Laurie C; Harris, Susan J; Klein, Michael C; Reime, Birgit
2005-01-01
To evaluate the success of a competency-based nursing orientation programme for a single-room maternity care unit by measuring improvement in self-reported competency after six months. Single-room maternity care has challenged obstetrical nurses to provide comprehensive nursing care during all phases of the in-hospital birth experience. In this model, nurses provide intrapartum, postpartum and newborn care in one room. To date, an evaluation of nursing education for single-room maternity care has not been published. A prospective cohort design comparing self-reported competencies prior to starting work in the single-room maternity care and six months after. Nurses completed a competency-based education programme in which they could select from a menu of learning methods and content areas according to their individual needs. Learning methods included classroom lectures, self-paced learning packages, and preceptorships in the clinical area. Competencies were measured by a standardized perinatal self-efficacy tool and a tool developed by the authors for this study, the Single-Room Maternity Care Competency Tool. A paired analysis was undertaken to take into account the paired (before and after) nature of the design. Scores on the perinatal self-efficacy scale and the single-room maternity care competency tool were improved. These differences were statistically significant. Improvements in perinatal and single-room maternity care-specific competencies suggest that our education programme was successful in preparing nurses for their new role in the single-room maternity care setting. This conclusion is supported by reported increases in nursing and patient satisfaction in the single-room maternity care compared with the traditional labour/delivery and postpartum settings. An education programme tailored to the learning needs of experienced clinical nurses contributes to improvements in nursing competencies and patient care.
Cortical interactions in vision and awareness: hierarchies in reverse.
Juan, Chi-Hung; Campana, Gianluca; Walsh, Vincent
2004-01-01
The anatomical connections between visual areas can be organized in 'feedforward', 'feedback' or 'horizontal' laminar patterns. We report here four experiments that test the function of some of the feedback projections in visual cortex. Projections from V5 to V1 have been suggested to be important in visual awareness, and in the first experiment we show this to be the case in the blindsight patient GY. This demonstration is replicated, in principle, in the second experiment and we also show the timing of the V5-V1 interaction to correspond to findings from single unit physiology. In the third experiment we show that V1 is important for stimulus detection in visual search arrays and that the timing of V1 interference with TMS is late (up to 240 ms after the onset of the visual array). Finally we report an experiment showing that the parietal cortex is not involved in visual motion priming, whereas V5 is, suggesting that the parietal cortex does not modulate V5 in this task. We interpret the data in terms of Bullier's recent physiological recordings and Ahissar and Hochstein's reverse hierarchy theory of vision.
Kol, Emine; Aydın, Perihan; Dursun, Oguz
2015-07-01
Noise is a substantial problem for both patients and healthcare workers in hospitals. This study aimed to determine the effectiveness of environmental strategies (creating single-patient rooms and reducing noise sources) in noise reduction in a pediatric intensive care unit. Noise measurement in the unit was conducted in two phases. In the first phase, measurements aimed at determining the unit's present level of noise were performed over 4 weeks in December 2013. During the month following the first measurement phase, the intensive care unit (ICU) was moved to a new location and noise-reducing strategies were implemented. The second phase, in May 2014, measured noise levels in the newly constructed environment. The noise levels before and after environmental changes were statistically significant at 72.6 dB-A and 56 dB-A, respectively (p < .05). Single-patient rooms and noise-reducing strategies can be effective in controlling environmental noise in the ICU. © 2015, Wiley Periodicals, Inc.
[Aftercare for durability and profitability of single-unit and multi-unit fixed dental prostheses].
de Baat, C; van Loveren, C; van der Maarel-Wierink, C D; Witter, D J; Creugers, N H J
2013-01-01
An important aim ofa treatment with single-unit and multi-unit fixed dental prostheses is a durable and profitable treatment outcome. That requires aftercare, too. First, the frequency of routine oral examinations should be assessed, using an individual risk profile. The objectives of the routine oral examinations are the prevention and, when necessary, the treatment of pathological conditions and complications. With regard to prevention, attention should be paid to information and instruction, oral biofilm and calculus, non-functional activities, hard tooth tissues, periodontal and peri-implant tissues, and saliva. Subsequently, it can be determined whether the intended durability and profitability have been achieved or can still be achieved, whether or not through indicated adjustments. Special attention should be paid to endodontically treated teeth. Restorative, repair or replacement treatments may be indicated in case ofcomplications, such as loose single- or multi-unitfixed dental prosthesis, fracture of a fixed dental prosthesis unit, lost tooth pulp vitality, tooth root fracture, and implant or implant abutment problems.
Minato, Takuo; Aravena, Daniel; Ruiz, Eliseo; Yamaguchi, Kazuya; Mizuno, Noritaka; Suzuki, Kosuke
2018-06-01
In this paper, the synthesis and magnetic properties of mononuclear Fe III -containing polyoxometalates (POMs) with different types of heteroatoms, TBA 7 H 10 [(A-α-XW 9 O 34 ) 2 Fe] (II X , X = Ge, Si; TBA = tetra- n-butylammonium), are reported. In these POMs, mononuclear highly distorted six-coordinate octahedral [FeO 6 ] 9- units are sandwiched by two trivacant lacunary units [A-α-XW 9 O 34 ] 10- (X = Ge, Si). These POMs exhibit field-induced slow magnetic relaxation based on the single high-spin Fe III magnetic center ( S = 5/2). Combining experiment and ab initio calculations, we investigated the effect of heteroatoms of the lacunary units on the field-induced slow magnetic relaxation of these POMs. By changing the heteroatoms from Si (II Si ) to Ge (II Ge ), the coordination geometry around the Fe III ion is mildly changed. Concretely, the axial Fe-O bond length in II Ge is shortened compared with that in II Si , and consequently the distortion of the [FeO 6 ] 9- unit in II Ge from the ideal octahedral coordination geometry becomes larger than that in II Si . The effective demagnetization barrier of II Ge (11.4 K) is slightly larger than that of II Si (9.2 K). Multireference ab initio calculations predict zero-field splitting parameters in good agreement with experiment. Although the differences in the coordination geometries and magnetic properties of II Ge and II Si are quite small, ab initio calculations indicate subtle changes in the magnetic anisotropy which are in line with the observed magnetic relaxation properties.
Amorphous silicon research. Final technical progress report, 1 August 1994--28 February 1998
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guha, S
1998-05-01
This report describes the status and accomplishments of work performed under this subcontract by United Solar Systems. United Solar researchers explored several new deposition regimes/conditions to investigate their effect on material/device performance. To facilitate optimum ion bombardment during growth, a large parameter space involving chamber pressure, rf power, and hydrogen dilution were investigated. United Solar carried out a series of experiments using discharge modulation at various pulsed-plasma intervals to study the effect of Si-particle incorporation on solar cell performance. Hydrogen dilution during deposition is found to improve both the initial and stable performance of a-Si and a-SiGe alloy cells. Researchersmore » conducted a series of temperature-ramping experiments on samples prepared with high and low hydrogen dilutions to study the effect of hydrogen effusion on solar cell performance. Using an internal photoemission method, the electrical bandgap of a microcrystalline p layer used in high-efficiency solar cells was measured to be 1.6 eV. New measurement techniques were developed to evaluate the interface and bulk contributions of losses to solar cell performance. Researchers replaced hydrogen with deuterium and found deuterated amorphous silicon alloy solar cells exhibit reduced light-induced degradation. The incorporation of a microcrystalline n layer in a multijunction cell is seen to improve cell performance. United Solar achieved a world-record single-junction a-Si alloy stable cell efficiency of 9.2% with an active area of 0.25 cm{sup 2} grown with high hydrogen dilution. They also achieved a world-record triple-junction, stable, active-area cell efficiency of 13.0% with an active area of 0.25 cm{sup 2}.« less
Single-Chain Folding of Synthetic Polymers: A Critical Update.
Altintas, Ozcan; Barner-Kowollik, Christopher
2015-11-23
The current contribution serves as a critical update to a previous feature article from us (Macromol. Rapid Commun. 2012, 33, 958-971), and highlights the latest advances in the preparation of single chain polymeric nanoparticles and initial-yet promising-attempts towards mimicking the structure of natural biomacromolecules via single-chain folding of well-defined linear polymers via so-called single chain selective point folding and repeat unit folding. The contribution covers selected examples from the literature published up to ca. September 2015. Our aim is not to provide an exhaustive review but rather highlight a selection of new and exciting examples for single-chain folding based on advanced macromolecular precision chemistry. Initially, the discussion focuses on the synthesis and characterization of single-chain folded structures via selective point folding. The second part of the feature article addresses the folding of well-defined single-chain polymers by means of repeat unit folding. The current state of the art in the field of single-chain folding indicates that repeat unit folding-driven nanoparticle preparation is well-advanced, while initial encouraging steps towards building selective point folding systems have been taken. In addition, a summary of the-in our view-open key questions is provided that may guide future biomimetic design efforts. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
[1990-1996: the experience of the La Fe Lung Transplant Group (Valencia)].
Borro Maté, J M; Morales Marín, P; Lozano Ruiz, C; Tarrazona Hervás, V; Galán Gil, G; Calvo Medina, V; Morant Guillén, P; Ramos Briones, F; Vicente Guillén, R; Paris Romeu, F
1997-10-01
Objective to review the experience of the lung transplantation unit at Hospital La Fe (Valencia). Between February 1990 and March 1996 we performed 40 lung transplants. The following causes were most common: cystic fibrosis (9 cases), emphysema (8), pulmonary fibrosis (8) and bronchiectasis (7). Types of intervention were 27 double lung transplants (25 sequential and 9 blocked), 9 single lung transplants, and 4 heart-lung transplants. We then reviewed the 36 single and double lung transplants. The main exclusion criteria were age over 65 years, malignant disease, kidney or liver disease, severe or non reversible central nervous system disease, and drug addiction. Prior surgery, mechanical ventilation and the presence of Aspergillus were considered lower-order contraindications. Mean patient age was 37.7 years (14-59). Six patients were colonized by Aspergillus before transplantation. Five had undergone earlier surgery and two were mechanically ventilated before the transplant. The most common complication was respiratory infection, which was present in 6 of the 7 patients who died. Other complications in order of frequency were dehiscence and/or bronchial stenosis, corticoid myopathy and postoperative bleeding. The actuarial survival rate of single and double lung transplants was 67.85 after 3 years, and 87.5% in patients with cystic fibrosis. Lung transplantation is a well-established procedure that is gradually being extended to treat more conditions. The main obstacle is the scarcity of donors. The main challenge at present is bronchiolitis obliterans.
Gas and water recycling system for IOC vivarium experiments
NASA Technical Reports Server (NTRS)
Nitta, K.; Otsubo, K.
1986-01-01
Water and gas recycling units designed as one of the common experiment support system for the life science experiment facilities used in the Japanese Experiment Module are discussed. These units will save transportation and operation costs for the life science experiments in the space station. These units are also designed to have interfaces so simple that the connection to another life science experiment facilities such as the Research Animal Holding Facility developed by the Rockheed Missiles and Space Company can be easily done with small modification.
Haanschoten, M C; van Straten, A H M; Verstappen, F; van de Kerkhof, D; van Zundert, A A J; Soliman Hamad, M A
2015-01-01
In our institution, we have redefined our criteria for direct availability of red blood cell (RBC) units in the operation room. In this study, we sought to evaluate the safety of applying this new logistical policy of blood transfusion in the first preliminary group of patients. In March 2010, we started a new policy concerning the elective availability of RBC units in the operation room. This policy was called: No Elective Red Cells (NERC) program. The program was applied for patients undergoing primary isolated coronary artery bypass grafting (CABG) or single valve surgery. No elective RBC units were preoperatively ordered for these patients. In case of urgent need, blood was delivered to the operating room within 20 min. The present study includes the first 500 patients who were managed according to this policy. Logistic regression analyses were performed to investigate the impact of biomedical variables on fulfilling this NERC program. The majority of patients (n = 409, 81 %) did not receive any RBCs during the hospital stay. In patients who did receive RBCs (n = 91, 19 %), 11 patients (2.2 %) received RBCs after 24 h postoperatively. Female gender, left ventricular ejection fraction (LVEF) and EuroSCORE were significant predictors for the need of blood transfusion (OR = 3.12; 2.79; 1.17 respectively). In a selected group of patients, it is safe to perform cardiac surgery without the immediate availability of RBCs in the operating room. Transfusion was avoided in 81 % of these patients. Female gender, LVEF and EuroSCORE were associated with blood transfusion.
A Saturn launched X-ray astronomy experiment. Volume 1: S-027
NASA Technical Reports Server (NTRS)
1971-01-01
The S-027 X-Ray Astronomy Experiment originally proposed in early 1966, was developed to detect X-rays in the 2 keV to 10 keV range. Both a prototype unit and flight unit were constructed with the prototype unit also serving as the engineering model, the qualification test unit, and after refurbishment, as the back-up flight unit. Two Ground Support Equipment consoles were built to verify the experiment operation. A photograph of one experiment package with its Ground Support Equipment is shown. The S-027 experiment was scheduled for launch in 1968/69 and although both units were completed and tested to the extent that either would be ready for the scheduled launch, delays in the space program resulted in a launch date slip of several years. When the 1968/69 launch delay became official, provisions were made for storage of the two experiment packages at SCI Electronics in Huntsville, Alabama until a new launch date could be established.
A tactile-output paging communication system for the deaf-blind
NASA Technical Reports Server (NTRS)
Baer, J. A.
1979-01-01
A radio frequency paging communication system that has coded vibrotactile outputs suitable for use by deaf-blind people was developed. In concept, the system consists of a base station transmitting and receiving unit and many on-body transmitting and receiving units. The completed system has seven operating modes: fire alarm; time signal; repeated single character Morse code; manual Morse code; emergency aid request; operational status test; and message acknowledge. The on-body units can be addressed in three ways: all units; a group of units; or an individual unit. All the functions developed were integrated into a single package that can be worn on the user's wrist. The control portion of the on-body unit is implemented by a microcomputer. The microcomputer is packaged in a custom-designed hybrid circuit to reduce its physical size.
Bayesian Estimation of Random Coefficient Dynamic Factor Models
ERIC Educational Resources Information Center
Song, Hairong; Ferrer, Emilio
2012-01-01
Dynamic factor models (DFMs) have typically been applied to multivariate time series data collected from a single unit of study, such as a single individual or dyad. The goal of DFMs application is to capture dynamics of multivariate systems. When multiple units are available, however, DFMs are not suited to capture variations in dynamics across…
47 CFR 68.105 - Minimum point of entry (MPOE) and demarcation point.
Code of Federal Regulations, 2010 CFR
2010-10-01
... be either the closest practicable point to where the wiring crosses a property line or the closest practicable point to where the wiring enters a multiunit building or buildings. The reasonable and... situations. (c) Single unit installations. For single unit installations existing as of August 13, 1990, and...
24 CFR 982.402 - Subsidy standards.
Code of Federal Regulations, 2010 CFR
2010-04-01
... the family in determining the family unit size. (5) A family that consists of a pregnant woman (with..., the family unit size for any family consisting of a single person must be either a zero or one-bedroom... other personal circumstances. (For a single person other than a disabled or elderly person or remaining...
A New Heat Supply System of Cogeneration for the Local Community
NASA Astrophysics Data System (ADS)
Yamaguchi, Hideki; Hisazumi, Yoshinori; Asano, Hitoshi; Morita, Hikaru; Hori, Toshihiro; Matsumoto, Toshiki; Abiko, Tetsuo
In order for economically viable distributed generation systems for local communities to be widely accepted, it is essential to develop an efficient and low-cost heat supply system. For this purpose, we propose a new heat supply system which we already presented at the ICOPE-05 Chicago. The key technology for the system is to connect compact heat supply units with a heat storage function installed in all the households of the local community, such as condominiums, by a single-loop of hot water pipe. A phase change material was used for the heat supply unit as the heat storage material. However, for easier handling and reducing the cost of the unit, we have developed a new heat supply unit whose heat storage tank is made of plastic. Hot water for space heating is used as the heat storage material. Further we constructed a heat supply system for 7 lived-in households with a 5 kW gas engine and a 42 kW boiler as the heat sources. Some experiments with a heat supply unit and a heat supply system, such as for heat storage and heat supply for peak demand were conducted. Additionally, dynamic simulations of heat demand by 50 households and a COP evaluation of a new CO2 heat pump system using low-temperature exhaust gas from the gas engine were also conducted.
Fritzsche, J; Denysenko, D; Grzywa, M; Volkmer, D
2017-11-07
The synthesis and crystal structure of the mixed-valent perfluorinated metal-organic framework (Me 2 NH 2 )[CFA-13] (Coordination Framework Augsburg University-13), (Me 2 NH 2 )[CuCu(tfpc) 4 ] (H 2 -tfpc = 3,5-bis(trifluoromethyl)-1H-pyrazole-4-carboxylic acid) is described. The copper-containing MOF crystallizes in the monoclinic crystal system within the space group P2 1 /n (no. 14) and the unit cell parameters are as follows: a = 22.3887(19), b = 13.6888(8), c = 21.1804(13) Å, β = 90.495(3)°, V = 6491.0(8) Å 3 . (Me 2 NH 2 )[CFA-13] features a porous 3-D structure constructed from two types of secondary building units (SBUs). Besides novel trinuclear [Cu(pz) 4 ] - coordination units, the network also exhibits Cu(ii) paddle-wheel SBUs. (Me 2 NH 2 )[CFA-13] is fully characterized by single crystal X-ray diffraction, thermogravimetric analysis, variable temperature powder X-ray diffraction, IR spectroscopy, photoluminescence, gas sorption measurements and pulse chemisorption experiments. M[CFA-13] (M = K + , Cs + ) frameworks were prepared by postsynthetic exchange of interchannel dimethylammonium cations. Moreover, it was shown that CO molecules can be selectively bound at Cu(i) sites of [Cu(pz) 4 ] - units, whereas Cu(ii) paddle-wheel units bind selectively NH 3 molecules.
A Laser-Based Measuring System for Online Quality Control of Car Engine Block
Li, Xing-Qiang; Wang, Zhong; Fu, Lu-Hua
2016-01-01
For online quality control of car engine production, pneumatic measurement instrument plays an unshakeable role in measuring diameters inside engine block because of its portability and high-accuracy. To the limitation of its measuring principle, however, the working space between the pneumatic device and measured surface is too small to require manual operation. This lowers the measuring efficiency and becomes an obstacle to perform automatic measurement. In this article, a high-speed, automatic measuring system is proposed to take the place of pneumatic devices by using a laser-based measuring unit. The measuring unit is considered as a set of several measuring modules, where each of them acts like a single bore gauge and is made of four laser triangulation sensors (LTSs), which are installed on different positions and in opposite directions. The spatial relationship among these LTSs was calibrated before measurements. Sampling points from measured shaft holes can be collected by the measuring unit. A unified mathematical model was established for both calibration and measurement. Based on the established model, the relative pose between the measuring unit and measured workpiece does not impact the measuring accuracy. This frees the measuring unit from accurate positioning or adjustment, and makes it possible to realize fast and automatic measurement. The proposed system and method were finally validated by experiments. PMID:27834839
Lee, Michael S Y; Ho, Simon Y W
2016-05-23
In the 1960s, several groups of scientists, including Emile Zuckerkandl and Linus Pauling, had noted that proteins experience amino acid replacements at a surprisingly consistent rate across very different species. This presumed single, uniform rate of genetic evolution was subsequently described using the term 'molecular clock'. Biologists quickly realised that such a universal pacemaker could be used as a yardstick for measuring the timescale of evolutionary divergences: estimating the rate of amino acid exchanges per unit of time and applying it to protein differences across a range of organisms would allow deduction of the divergence times of their respective lineages (Figure 1). Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Gualtierotti, T.; Bracchi, F.
1972-01-01
The technique of single unit recording from body systems generating electrical pulses coherent with their basic function (CNS, muscles, sense organs) has been proved feasible during the OFO A orbital flight, an automatic physiological experiment. The results of recording 155 hours of orbital flight of pulses from the nerve fibres of four vestibular gravity sensors in two bull frogs indicate that the vestibular organ adjusts to zero g. As all the other biological changes observed during orbit are due to lack of exercise, it is concluded that artificial gravity might not be necessary during prolonged space missions or on low gravity celestial bodies.
Analysis of long-time operation of micro-cogeneration unit with fuel cell
NASA Astrophysics Data System (ADS)
Patsch, Marek; Čaja, Alexander
2015-05-01
Micro-cogeneration is cogeneration with small performance, with maximal electric power up to 50 kWe. On the present, there are available small micro-cogeneration units with small electric performance, about 1 kWe, which are usable also in single family houses or flats. These micro-cogeneration units operate on principle of conventional combustion engine, Stirling engine, steam engine or fuel cell. Micro-cogeneration units with fuel cells are new progressive developing type of units for single family houses. Fuel cell is electrochemical device which by oxidation-reduction reaction turn directly chemical energy of fuel to electric power, secondary products are pure water and thermal energy. The aim of paper is measuring and evaluation of operation parameters of micro-cogeneration unit with fuel cell which uses natural gas as a fuel.
Mohr, Maurice; Nann, Marius; von Tscharner, Vinzenz; Eskofier, Bjoern; Nigg, Benno Maurus
2015-01-01
Motor unit activity is coordinated between many synergistic muscle pairs but the functional role of this coordination for the motor output is unclear. The purpose of this study was to investigate the short-term modality of coordinated motor unit activity-the synchronized discharge of individual motor units across muscles within time intervals of 5ms-for the Vastus Medialis (VM) and Lateralis (VL). Furthermore, we studied the task-dependency of intermuscular motor unit synchronization between VM and VL during static and dynamic squatting tasks to provide insight into its functional role. Sixteen healthy male and female participants completed four tasks: Bipedal squats, single-leg squats, an isometric squat, and single-leg balance. Monopolar surface electromyography (EMG) was used to record motor unit activity of VM and VL. For each task, intermuscular motor unit synchronization was determined using a coherence analysis between the raw EMG signals of VM and VL and compared to a reference coherence calculated from two desynchronized EMG signals. The time shift between VM and VL EMG signals was estimated according to the slope of the coherence phase angle spectrum. For all tasks, except for singe-leg balance, coherence between 15-80Hz significantly exceeded the reference. The corresponding time shift between VM and VL was estimated as 4ms. Coherence between 30-60Hz was highest for the bipedal squat, followed by the single-leg squat and the isometric squat. There is substantial short-term motor unit synchronization between VM and VL. Intermuscular motor unit synchronization is enhanced for contractions during dynamic activities, possibly to facilitate a more accurate control of the joint torque, and reduced during single-leg tasks that require balance control and thus, a more independent muscle function. It is proposed that the central nervous system scales the degree of intermuscular motor unit synchronization according to the requirements of the movement task at hand.
Mohr, Maurice; Nann, Marius; von Tscharner, Vinzenz; Eskofier, Bjoern; Nigg, Benno Maurus
2015-01-01
Purpose Motor unit activity is coordinated between many synergistic muscle pairs but the functional role of this coordination for the motor output is unclear. The purpose of this study was to investigate the short-term modality of coordinated motor unit activity–the synchronized discharge of individual motor units across muscles within time intervals of 5ms–for the Vastus Medialis (VM) and Lateralis (VL). Furthermore, we studied the task-dependency of intermuscular motor unit synchronization between VM and VL during static and dynamic squatting tasks to provide insight into its functional role. Methods Sixteen healthy male and female participants completed four tasks: Bipedal squats, single-leg squats, an isometric squat, and single-leg balance. Monopolar surface electromyography (EMG) was used to record motor unit activity of VM and VL. For each task, intermuscular motor unit synchronization was determined using a coherence analysis between the raw EMG signals of VM and VL and compared to a reference coherence calculated from two desynchronized EMG signals. The time shift between VM and VL EMG signals was estimated according to the slope of the coherence phase angle spectrum. Results For all tasks, except for singe-leg balance, coherence between 15–80Hz significantly exceeded the reference. The corresponding time shift between VM and VL was estimated as 4ms. Coherence between 30–60Hz was highest for the bipedal squat, followed by the single-leg squat and the isometric squat. Conclusion There is substantial short-term motor unit synchronization between VM and VL. Intermuscular motor unit synchronization is enhanced for contractions during dynamic activities, possibly to facilitate a more accurate control of the joint torque, and reduced during single-leg tasks that require balance control and thus, a more independent muscle function. It is proposed that the central nervous system scales the degree of intermuscular motor unit synchronization according to the requirements of the movement task at hand. PMID:26529604
Using Field-Metered Data to Quantify Annual Energy Use of Portable Air Conditioners
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burke, Thomas; Willem, Henry; Ni, Chun Chun
2014-12-01
As many regions of the United States experience rising temperatures, consumers have come to rely increasingly on cooling appliances (including portable air conditioners) to provide a comfortable indoor temperature. Home occupants sometimes use a portable air conditioner (PAC) to maintain a desired indoor temperature in a single room or enclosed space. Although PACs in residential use are few compared to centrally installed and room air conditioning (AC) units, the past few years have witnessed an increase of PACs use throughout the United States. There is, however, little information and few research projects focused on the energy consumption and performance ofmore » PACs, particularly studies that collect information from field applications of PACs. The operation and energy consumption of PACs may differ among geographic locations and households, because of variations in cooling load, frequency, duration of use, and other user-selected settings. In addition, the performance of building envelope (thermal mass and air leakage) as well as inter-zonal mixing within the building would substantially influence the ability to control and maintain desirable indoor thermal conditions. Lawrence Berkeley National Laboratory (LBNL) conducted an initial field-metering study aimed at increasing the knowledge and data related to PAC operation and energy consumption in the United States.« less
Lee, Norman; Schrode, Katrina M; Bee, Mark A
2017-09-01
Diverse animals communicate using multicomponent signals. How a receiver's central nervous system integrates multiple signal components remains largely unknown. We investigated how female green treefrogs (Hyla cinerea) integrate the multiple spectral components present in male advertisement calls. Typical calls have a bimodal spectrum consisting of formant-like low-frequency (~0.9 kHz) and high-frequency (~2.7 kHz) components that are transduced by different sensory organs in the inner ear. In behavioral experiments, only bimodal calls reliably elicited phonotaxis in no-choice tests, and they were selectively chosen over unimodal calls in two-alternative choice tests. Single neurons in the inferior colliculus of awake, passively listening subjects were classified as combination-insensitive units (27.9%) or combination-sensitive units (72.1%) based on patterns of relative responses to the same bimodal and unimodal calls. Combination-insensitive units responded similarly to the bimodal call and one or both unimodal calls. In contrast, combination-sensitive units exhibited both linear responses (i.e., linear summation) and, more commonly, nonlinear responses (e.g., facilitation, compressive summation, or suppression) to the spectral combination in the bimodal call. These results are consistent with the hypothesis that nonlinearities play potentially critical roles in spectral integration and in the neural processing of multicomponent communication signals.
In situ impact of multiple pulses of metal and herbicide on the seagrass, Zostera capricorni.
Macinnis-Ng, Catriona M O; Ralph, Peter J
2004-04-28
Tides and freshwater inflow which influence water movement in estuarine areas govern the exposure-regime of pollutants. In this experiment, we examined the in situ impact of double pulses of copper and the herbicide Irgarol 1051 on the photosynthesis of the seagrass, Zostera capricorni. Despite a 4-day recovery period between the two 10h pulses of toxicant, the effective quantum yield of photosystem II (DeltaF/Fm') and total chlorophyll concentrations indicated that multiple-pulses had a greater impact than a single pulse. During the first exposure period, samples exposed to Irgarol 1051 had DeltaF/Fm' values as low as zero while controls remained around 0.6 relative units. After the second exposure period, treated samples recovered to only 0.4 relative units. Samples exposed to copper had DeltaF/Fm' values around 0.3 relative units during the first exposure period and while these samples recovered before the second dose, they remained below 0.2 relative units after the second exposure period. Alternate samples were also exposed to one toxicant, allowed to recover and then exposed to the other toxicant. DeltaF/Fm' values indicated that copper exposure followed by Irgarol 1051 exposure was more toxic than Irgarol 1051 exposure followed by copper exposure.
A compact, low jitter, nanosecond rise time, high voltage pulse generator with variable amplitude.
Mao, Jiubing; Wang, Xin; Tang, Dan; Lv, Huayi; Li, Chengxin; Shao, Yanhua; Qin, Lan
2012-07-01
In this paper, a compact, low jitter, nanosecond rise time, command triggered, high peak power, gas-switch pulse generator system is developed for high energy physics experiment. The main components of the system are a high voltage capacitor, the spark gap switch and R = 50 Ω load resistance built into a structure to obtain a fast high power pulse. The pulse drive unit, comprised of a vacuum planar triode and a stack of avalanche transistors, is command triggered by a single or multiple TTL (transistor-transistor logic) level pulses generated by a trigger pulse control unit implemented using the 555 timer circuit. The control unit also accepts user input TTL trigger signal. The vacuum planar triode in the pulse driving unit that close the first stage switches is applied to drive the spark gap reducing jitter. By adjusting the charge voltage of a high voltage capacitor charging power supply, the pulse amplitude varies from 5 kV to 10 kV, with a rise time of <3 ns and the maximum peak current up to 200 A (into 50 Ω). The jitter of the pulse generator system is less than 1 ns. The maximum pulse repetition rate is set at 10 Hz that limited only by the gas-switch and available capacitor recovery time.
Stewart, David; Zalamea, Nia; Waxman, Ken; Schuster, Rob; Bozuk, Michael
2006-10-01
Sequential compression devices (SCD) have become the most common form of prophylaxis against the formation of deep venous thrombosis (DVT) among surgical patients. However, compliance with SCD has traditionally been poor. The aim of this study was to assess the affect of patient and nurse education by surgeons on SCD compliance. This was a prospective study involving a single teaching hospital. Compliance was checked twice daily. The main outcomes were compliance rates with SCD use before and after nurse and patient education. Nurses were not aware of the study. Surgical floors had a history of resident and attending interactions regarding SCD, whereas nonsurgical floors did not. A handout that emphasized SCD importance was also given to patients on surgical units. Before education, surgical units had a compliance rate of 61.5 per cent, whereas nonsurgical units had a 48 per cent compliance rate. This difference was significant (P = 0.014). After nursing and patient education on the busiest surgical floor, compliance rates on the surgical ward increased to 65 per cent, a difference that was not of statistical significance (P = 0.515). A nursing unit's daily experience is the most important factor in their compliance rates with SCD use. Focused nursing lectures and patient education may have incremental value.
Vocational Agriculture I Basic Core. Section C--Supervised Experience Programs.
ERIC Educational Resources Information Center
Oklahoma State Board of Vocational and Technical Education, Stillwater. Curriculum and Instructional Materials Center.
This curriculum guide contains five units teaching preservice vocational teachers to conduct supervised experience programs. Each unit contains an objective (e.g., "After completing this unit, the student should be able to choose and plan supervised occupational experience programs"); specific objectives (e.g., "State reasons for…
Music and movement share a dynamic structure that supports universal expressions of emotion
Sievers, Beau; Polansky, Larry; Casey, Michael; Wheatley, Thalia
2013-01-01
Music moves us. Its kinetic power is the foundation of human behaviors as diverse as dance, romance, lullabies, and the military march. Despite its significance, the music-movement relationship is poorly understood. We present an empirical method for testing whether music and movement share a common structure that affords equivalent and universal emotional expressions. Our method uses a computer program that can generate matching examples of music and movement from a single set of features: rate, jitter (regularity of rate), direction, step size, and dissonance/visual spikiness. We applied our method in two experiments, one in the United States and another in an isolated tribal village in Cambodia. These experiments revealed three things: (i) each emotion was represented by a unique combination of features, (ii) each combination expressed the same emotion in both music and movement, and (iii) this common structure between music and movement was evident within and across cultures. PMID:23248314
Positron-annihilation study of the electronic structure of URu2Si2
NASA Astrophysics Data System (ADS)
Rozing, G. J.; Mijnarends, P. E.; Menovsky, A. A.; de Chtel, P. F.
1991-04-01
Measurements of the two-dimensional angular correlation of annihilation radiation (2D-ACAR) were performed on oriented single crystals of URu2Si2. The spectra, obtained with integration along four different symmetry directions, display anisotropic structure in fair agreement with a previous calculation of the two-photon momentum distribution. In particular, the contribution of the f-ligand hybridized electron states is clearly observed and reasonably well described by the band calculation. The 2D-ACAR distribution remains unchanged as the temperature is increased from 6 K in the Fermi-liquid state to 72 K, which is just above the coherence temperature. The inhomogeneity of the positron density in the unit cell complicates the Lock-Crisp-West (LCW) analysis of the experiments in terms of Fermi-surface features. Nevertheless, the disagreement between theory and experiment after LCW folding indicates that the Fermi surface as predicted by local-density-approximation band theory does not apply.
Yanagisawa, Yasuhide; Chatake, Toshiyuki; Chiba-Kamoshida, Kaori; Naito, Sawa; Ohsugi, Tadanori; Sumi, Hiroyuki; Yasuda, Ichiro; Morimoto, Yukio
2010-12-01
Nattokinase is a single polypeptide chain composed of 275 amino acids (molecular weight 27,724) which displays strong fibrinolytic activity. Moreover, it can activate other fibrinolytic enzymes such as pro-urokinase and tissue plasminogen activator. In the present study, native nattokinase from Bacillus subtilis natto was purified using gel-filtration chromatography and crystallized to give needle-like crystals which could be used for X-ray diffraction experiments. The crystals belonged to space group C2, with unit-cell parameters a=74.3, b=49.9, c=56.3 Å, β=95.2°. Diffraction images were processed to a resolution of 1.74 Å with an Rmerge of 5.2% (15.3% in the highest resolution shell) and a completeness of 69.8% (30.0% in the highest resolution shell). This study reports the first X-ray diffraction analysis of nattokinase.
Yanagisawa, Yasuhide; Chatake, Toshiyuki; Chiba-Kamoshida, Kaori; Naito, Sawa; Ohsugi, Tadanori; Sumi, Hiroyuki; Yasuda, Ichiro; Morimoto, Yukio
2010-01-01
Nattokinase is a single polypeptide chain composed of 275 amino acids (molecular weight 27 724) which displays strong fibrinolytic activity. Moreover, it can activate other fibrinolytic enzymes such as pro-urokinase and tissue plasminogen activator. In the present study, native nattokinase from Bacillus subtilis natto was purified using gel-filtration chromatography and crystallized to give needle-like crystals which could be used for X-ray diffraction experiments. The crystals belonged to space group C2, with unit-cell parameters a = 74.3, b = 49.9, c = 56.3 Å, β = 95.2°. Diffraction images were processed to a resolution of 1.74 Å with an R merge of 5.2% (15.3% in the highest resolution shell) and a completeness of 69.8% (30.0% in the highest resolution shell). This study reports the first X-ray diffraction analysis of nattokinase. PMID:21139221
Robust Online Hamiltonian Learning
NASA Astrophysics Data System (ADS)
Granade, Christopher; Ferrie, Christopher; Wiebe, Nathan; Cory, David
2013-05-01
In this talk, we introduce a machine-learning algorithm for the problem of inferring the dynamical parameters of a quantum system, and discuss this algorithm in the example of estimating the precession frequency of a single qubit in a static field. Our algorithm is designed with practicality in mind by including parameters that control trade-offs between the requirements on computational and experimental resources. The algorithm can be implemented online, during experimental data collection, or can be used as a tool for post-processing. Most importantly, our algorithm is capable of learning Hamiltonian parameters even when the parameters change from experiment-to-experiment, and also when additional noise processes are present and unknown. Finally, we discuss the performance of the our algorithm by appeal to the Cramer-Rao bound. This work was financially supported by the Canadian government through NSERC and CERC and by the United States government through DARPA. NW would like to acknowledge funding from USARO-DTO.
Load type influences motor unit recruitment in biceps brachii during a sustained contraction.
Baudry, Stéphane; Rudroff, Thorsten; Pierpoint, Lauren A; Enoka, Roger M
2009-09-01
Twenty subjects participated in four experiments designed to compare time to task failure and motor-unit recruitment threshold during contractions sustained at 15% of maximum as the elbow flexor muscles either supported an inertial load (position task) or exerted an equivalent constant torque against a rigid restraint (force task). Subcutaneous branched bipolar electrodes were used to record single motor unit activity from the biceps brachii muscle during ramp contractions performed before and at 50 and 90% of the time to failure for the position task during both fatiguing contractions. The time to task failure was briefer for the position task than for the force task (P=0.0002). Thirty and 29 motor units were isolated during the force and position tasks, respectively. The recruitment threshold declined by 48 and 30% (P=0.0001) during the position task for motor units with an initial recruitment threshold below and above the target force, respectively, whereas no significant change in recruitment threshold was observed during the force task. Changes in recruitment threshold were associated with a decrease in the mean discharge rate (-16%), an increase in discharge rate variability (+40%), and a prolongation of the first two interspike intervals (+29 and +13%). These data indicate that there were faster changes in motor unit recruitment and rate coding during the position task than the force task despite a similar net muscle torque during both tasks. Moreover, the results suggest that the differential synaptic input observed during the position task influences most of the motor unit pool.
Elvin, Stephen J; Eyles, James E; Howard, Kenneth A; Ravichandran, Easwaran; Somavarappu, Satyanarayan; Alpar, H Oya; Williamson, E Diane
2006-05-15
Protection against virulent plague challenge by the parenteral and aerosol routes was afforded by a single administration of microencapsulated Caf1 and LcrV antigens from Yersinia pestis in BALB/c mice. Recombinant Caf1 and LcrV were individually encapsulated in polymeric microspheres, to the surface of which additional antigen was adsorbed. The microspheres containing either Caf1 or LcrV were blended and used to immunise mice on a single occasion, by either the intra-nasal or intra-muscular route. Both routes of immunisation induced systemic and local immune responses, with high levels of serum IgG being developed in response to both vaccine antigens. In Elispot assays, secretion of cytokines by spleen and draining lymph node cells was demonstrated, revealing activation of both Th1 and Th2 associated cytokines; and spleen cells from animals immunised by either route were found to proliferate in vitro in response to both vaccine antigens. Virulent challenge experiments demonstrated that non-invasive immunisation by intra-nasal instillation can provide strong systemic and local immune responses and protect against high level challenge. Microencapsulation of these vaccine antigens has the added advantage that controlled release of the antigens occurs in vivo, so that protective immunity can be induced after only a single immunising dose.
Hybrid intracerebral probe with integrated bare LED chips for optogenetic studies.
Ayub, Suleman; Gentet, Luc J; Fiáth, Richárd; Schwaerzle, Michael; Borel, Mélodie; David, François; Barthó, Péter; Ulbert, István; Paul, Oliver; Ruther, Patrick
2017-09-01
This article reports on the development, i.e., the design, fabrication, and validation of an implantable optical neural probes designed for in vivo experiments relying on optogenetics. The probes comprise an array of ten bare light-emitting diode (LED) chips emitting at a wavelength of 460 nm and integrated along a flexible polyimide-based substrate stiffened using a micromachined ladder-like silicon structure. The resulting mechanical stiffness of the slender, 250-μm-wide, 65-μm-thick, and 5- and 8-mm-long probe shank facilitates its implantation into neural tissue. The LEDs are encapsulated by a fluropolymer coating protecting the implant against the physiological conditions in the brain. The electrical interface to the external control unit is provided by 10-μm-thick, highly flexible polyimide cables making the probes suitable for both acute and chronic in vivo experiments. Optical and electrical properties of the probes are reported, as well as their in vivo validation in acute optogenetic studies in transgenic mice. The depth-dependent optical stimulation of both excitatory and inhibitory neurons is demonstrated by altering the brain activity in the cortex and the thalamus. Local network responses elicited by 20-ms-long light pulses of different optical power (20 μW and 1 mW), as well as local modulation of single unit neuronal activity to 1-s-long light pulses with low optical intensity (17 μW) are presented. The ability to modulate neural activity makes these devices suitable for a broad variety of optogenetic experiments.
Abstract feature codes: The building blocks of the implicit learning system.
Eberhardt, Katharina; Esser, Sarah; Haider, Hilde
2017-07-01
According to the Theory of Event Coding (TEC; Hommel, Müsseler, Aschersleben, & Prinz, 2001), action and perception are represented in a shared format in the cognitive system by means of feature codes. In implicit sequence learning research, it is still common to make a conceptual difference between independent motor and perceptual sequences. This supposedly independent learning takes place in encapsulated modules (Keele, Ivry, Mayr, Hazeltine, & Heuer 2003) that process information along single dimensions. These dimensions have remained underspecified so far. It is especially not clear whether stimulus and response characteristics are processed in separate modules. Here, we suggest that feature dimensions as they are described in the TEC should be viewed as the basic content of modules of implicit learning. This means that the modules process all stimulus and response information related to certain feature dimensions of the perceptual environment. In 3 experiments, we investigated by means of a serial reaction time task the nature of the basic units of implicit learning. As a test case, we used stimulus location sequence learning. The results show that a stimulus location sequence and a response location sequence cannot be learned without interference (Experiment 2) unless one of the sequences can be coded via an alternative, nonspatial dimension (Experiment 3). These results support the notion that spatial location is one module of the implicit learning system and, consequently, that there are no separate processing units for stimulus versus response locations. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Chalmers, Gordon R
2008-01-01
Literature examining the recruitment order of motor units during lengthening (eccentric) contractions was reviewed to determine if fast-twitch motor units can be active while lower threshold slow-twitch motor units are not active. Studies utilizing surface electromyogram (EMG) amplitude, single motor unit activity, spike amplitude-frequency analyses, EMG power spectrum, mechanomyographic, and phosphocreatine-to-creatine ratio (PCr/Cr) techniques were reviewed. Only single motor unit and PCr/Cr data were found to be suitable to address the goals of this review. Nine of ten single motor unit studies, examining joint movement velocities up to 225 degrees/s and forces up to 53% of a maximum voluntary contraction, found that the size principle of motor unit recruitment applied during lengthening contractions. Deviation from the size principle was demonstrated by one study examining movements within a small range of low velocities and modest forces, although other studies examining similar low forces and lengthening velocities reported size-ordered recruitment. The PCr/Cr data demonstrated the activation of all fibre types in lengthening maximal contractions. Most evidence indicates that for lengthening contractions of a wide range of efforts and speeds, fast-twitch muscle fibres cannot be selectively recruited without activity of the slow-twitch fibres of the same muscle.
49 CFR 180.519 - Periodic retest and inspection of tank cars other than single-unit tank car tanks.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 3 2011-10-01 2011-10-01 false Periodic retest and inspection of tank cars other than single-unit tank car tanks. 180.519 Section 180.519 Transportation Other Regulations Relating to... (CONTINUED) CONTINUING QUALIFICATION AND MAINTENANCE OF PACKAGINGS Qualification and Maintenance of Tank Cars...
49 CFR 180.519 - Periodic retest and inspection of tank cars other than single-unit tank car tanks.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 3 2013-10-01 2013-10-01 false Periodic retest and inspection of tank cars other than single-unit tank car tanks. 180.519 Section 180.519 Transportation Other Regulations Relating to... (CONTINUED) CONTINUING QUALIFICATION AND MAINTENANCE OF PACKAGINGS Qualification and Maintenance of Tank Cars...
49 CFR 180.519 - Periodic retest and inspection of tank cars other than single-unit tank car tanks.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 3 2012-10-01 2012-10-01 false Periodic retest and inspection of tank cars other than single-unit tank car tanks. 180.519 Section 180.519 Transportation Other Regulations Relating to... (CONTINUED) CONTINUING QUALIFICATION AND MAINTENANCE OF PACKAGINGS Qualification and Maintenance of Tank Cars...
49 CFR 180.519 - Periodic retest and inspection of tank cars other than single-unit tank car tanks.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 3 2014-10-01 2014-10-01 false Periodic retest and inspection of tank cars other than single-unit tank car tanks. 180.519 Section 180.519 Transportation Other Regulations Relating to... (CONTINUED) CONTINUING QUALIFICATION AND MAINTENANCE OF PACKAGINGS Qualification and Maintenance of Tank Cars...
25 CFR 171.210 - Where will BIA provide my irrigation service?
Code of Federal Regulations, 2010 CFR
2010-04-01
... water to your farm unit from a single delivery point; (2) You agree in writing to be responsible for all... Section 171.210 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER IRRIGATION... will provide service to your farm unit at a single delivery point that we designate. (b) At our...
25 CFR 171.210 - Where will BIA provide my irrigation service?
Code of Federal Regulations, 2011 CFR
2011-04-01
... water to your farm unit from a single delivery point; (2) You agree in writing to be responsible for all... Section 171.210 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAND AND WATER IRRIGATION... will provide service to your farm unit at a single delivery point that we designate. (b) At our...
Understanding the Earth's Mantle Through Advanced Elasticity Measurements
NASA Astrophysics Data System (ADS)
Marquardt, Hauke; Schulze, Kirsten; Kurnosov, Alexander; Buchen, Johannes; Frost, Daniel; Boffa Ballaran, Tiziana; Marquardt, Katharina; Kawazoe, Takaaki
2017-04-01
Constraints on the inner structure, chemical and mineralogical composition as well as dynamics of Earth's mantle can be derived through comparison of laboratory elasticity data to seismological observables. A quantitative knowledge of the elastic properties of mantle minerals, and their variations with chemical composition, at pressure and temperature conditions of Earth's mantle is key to construct reliable synthetic mineral physics-based seismic velocity models to be compared to seismic observables. We will discuss results of single-crystal elasticity measurements on Earth mantle minerals that have been conducted using the combined Brillouin scattering and x-ray diffraction (XRD) system at BGI Bayreuth in combination with advanced sample preparation using the focused ion beam (FIB) technique [1] that allows for tailoring sizes and shapes of tiny single-crystals. In our experiments, multiple FIB-prepared single-crystals were loaded in a single sample chamber of a resistively-heated diamond-anvil cell (DAC). The possiblity to measure simultaneously acoustic wave velocities and density (unit-cell parameters) in the DAC in combination with the multi-sample approach facilitates direct quantification of the effects of chemical substitution on the elasticity and seismic wave velocities at non-ambient conditions. Our experimental approach eliminates uncertainties arising from the combination of data collected under (potentially) different conditions in several DAC runs, in different laboratories and/or from using different pressure-temperature sensors. We will present our recent experiments on the elasticity of single-crystal Fe-Al-bearing bridgmanite in the lower mantle and discuss implications for the composition and oxidation state of Earth's lower mantle. We will further discuss our laboratory data on the effects of 'water' and iron on the seismic wave velocities of ringwoodite in Earth's transition zone and outline implications for mapping 'water' in the transition zone using geophysical observables. [1] Marquardt, H. and K. Marquardt, 2012. American Mineralogist 97, 299-304.
Predicting Envelope Leakage in Attached Dwellings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Faakye, O.; Arena, L.; Griffiths, D.
2013-07-01
The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, andmore » control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.« less
Kim, Jung-Eun; Lee, Jin Yong; Lee, Sang Hyung
2018-05-10
This study aims to explore single mothers’ experiences with social services/policies for their independent living and to identify gaps between these experiences and the needs of single mothers. A focus group discussion was performed to collect data. Seven single mothers discussed their experiences in significant periods of their lives: pregnancy, childbirth, and parenting. Findings from the qualitative thematic analysis show discrepancies between the direction of social services/policies and single mothers’ needs, in terms of difficulties in healthcare, childcare, housing, employment, and income security. To the single mothers in this study, the social safety net is not inclusive, compared to that which is available to two-parent families or adoptive families. It is necessary to intervene in current blind spots of services/policies for single mothers, and to provide a social safety net to strengthen single mothers’ self-reliance and their children’s social security in the long term.
Kim, Jung-Eun; Lee, Sang Hyung
2018-01-01
This study aims to explore single mothers’ experiences with social services/policies for their independent living and to identify gaps between these experiences and the needs of single mothers. A focus group discussion was performed to collect data. Seven single mothers discussed their experiences in significant periods of their lives: pregnancy, childbirth, and parenting. Findings from the qualitative thematic analysis show discrepancies between the direction of social services/policies and single mothers’ needs, in terms of difficulties in healthcare, childcare, housing, employment, and income security. To the single mothers in this study, the social safety net is not inclusive, compared to that which is available to two-parent families or adoptive families. It is necessary to intervene in current blind spots of services/policies for single mothers, and to provide a social safety net to strengthen single mothers’ self-reliance and their children’s social security in the long term. PMID:29748484
Spatiotemporal configuration dependent pairing of nerve events in dark-adapted human vision
NASA Astrophysics Data System (ADS)
Bouman, Maarten A.
2002-02-01
In the model presented here, in the dark any single quantum absorption in a rod or cone produces a subliminal excitation. Subliminal excitations from both halves of a twin unit pair in the retina for the perception of light from the stimulus. A twin unit contains either two red or two green cones. The twin units are intertwined in triples of two red units and one green unit in a hexagon called a trion. P satellite rods surround each cone, P being approximately proportional to the square of eccentricity. A successful pairing for light perception represents-through the points of time and locations of the creation of its partners in the retina-a direction event with two possible polarities and with the orientation of the elongated shape of the twin unit. The polarity of the event depends on which of the two partners arrives first at the twin's pairing facility. Simultaneous events and successive events with the same polarity in adjacent units that are aligned along one of the three orientations of the hexagonal retinal mosaic pair in the cortex for the perception of edge and of movement. Inter-twin pairing products of the three differently oriented sets of aligned twins are independent of each other and sum vectorially in the cortex. This system of three sub-retinas is called the retrinet. Two one-quantum excitations in any of a twin's receptors make the percept colored. The odd blue cone produces already a blue signal for a single one-quantum excitation. Intra-receptor pairing in a rod, a red cone and a green cone is for white, red, and green respectively. Red and green cone products of a trion cross-pair in the retina and produce a yellow signal. Red and green cone products of a hexagon of adjacent trions cross-pair in the cortex and produce a white signal. This large hexagon with a total of seven trions is called a persepton. After subliminal excitations in a twin have paired successfully, further subliminal receptor excitations in neighboring and aligned twins are expressed to a certain extent in the percept's area, duration and color. Earlier experiments on absolute and color thresholds are the basis for this theory, which is developed in this paper.
Norfolk, Stephanie G; Hollingsworth, Caroline L; Wolfe, Cameron R; Govert, Joseph A; Que, Loretta G; Cheifetz, Ira M; Hollingsworth, John W
2010-11-01
Severe respiratory failure is a well-recognized complication of pH1N1 influenza infection. Limited data regarding the efficacy of rescue therapies, including high-frequency oscillatory ventilation and extracorporeal membrane oxygenation, have been previously reported in the setting of pH1N1 influenza infection in the United States. Retrospective, single-center cohort study. Pediatric, cardiac, surgical, and medical intensive care units in a single tertiary care center in the United States. One hundred twenty-seven consecutive patients with confirmed influenza A infection requiring hospitalization between April 1, 2009, and October 31, 2009. Electronic medical records were reviewed for demographic and clinical data. The number of intensive care unit admissions appears inversely related to age with 39% of these admissions <20 yrs of age. Median duration of intensive care unit care was 10.0 days (4.0-24.0), and median duration of mechanical ventilation was 8.0 days (0.0-23.5). Rescue therapy (high-frequency oscillatory ventilation or extracorporeal membrane oxygenation) was used in 36% (12 of 33) of intensive care unit patients. The severity of respiratory impairment was determined by Pao²/Fio² ratio and oxygenation index. High-frequency oscillatory ventilation at 24 hrs resulted in improvements in median Pao²/Fio² ratio (71 [58-93] vs. 145 [126-185]; p < .001), oxygenation index (27 [20-30] vs. 18 [12-25]; p = .016), and Fio2 (100 [70-100] vs. 45 [40-55]; p < .001). Extracorporeal membrane oxygenation resulted in anticipated improvement in parameters of oxygenation at both 2 hrs and 24 hrs after initiation of therapy. Despite the severity of oxygenation impairment, overall survival for both rescue therapies was 75% (nine of 12), 80% (four of five) for high-frequency oscillatory ventilation alone, and 71% (five of seven) for high-frequency oscillatory ventilation + extracorporeal membrane oxygenation. In critically ill adult and pediatric patients with pH1N1 infection and severe lung injury, the use of high-frequency oscillatory ventilation and extracorporeal membrane oxygenation can result in significant improvements in Pao²/Fio² ratio, oxygenation index, and Fio². However, the impact on mortality is less certain.
Doubly negative isotropic elastic metamaterial for sub-wavelength focusing: Design and realization
NASA Astrophysics Data System (ADS)
Oh, Joo Hwan; Seung, Hong Min; Kim, Yoon Young
2017-12-01
In spite of much progress in elastic metamaterials, tuning the effective density and stiffness to desired values ranging from negatives to large positives is still difficult. In particular, simultaneous realization of double negativity and isotropy, critical in sub-wavelength focusing, is very challenging since anisotropy is usually unavoidable in resonance-based metamaterials. The main difficulty is that there is no established systematic design method for simultaneous achieving of double negativity and isotropy. Thus, we propose a unique elastic metamaterial unit cell with which simultaneous realization can be achieved by an explicit step-by-step approach. The unit cell of the proposed metamaterial can be accurately modeled as an equivalent mass-spring system so that the effective properties can be easily controlled with the design parameters. The actual realization was carried out by acquiring the desired properties in sequential steps which is in detail. The specific application for this study is on sub-wavelength focusing, which will be demonstrated by waves from a single point source focused on a region smaller than half the wavelength. Actual experiments were performed on an aluminum plate where the designed metamaterial flat lens was imbedded. The results acquired through simulations and experiments suggest potential applications of the proposed metamaterial and the systematic design approach in advanced acoustic surgery or non-destructive testing.
McDermott-Levy, Ruth
2011-01-01
Since 2004, international student enrollment in the United States has increased. Middle Eastern students studying in the United States have been part of the increase. In 2008-2009 there were 29 140 Middle Eastern students, representing an 18% increase from the previous academic year. Despite these increases, there is limited research examining the experience of Arab-Muslim international students or international nursing students studying in the United States. Phenomenological inquiry was used to describe the experience of 12 female Omani nurses living in the United States while studying for their baccalaureate degrees in nursing. The women described the experience of going alone and being away from the support and presence of their large, extended families; this influenced their international student experience. They also described their religious, cultural, and educational adaptation. The experience of living and studying nursing in the United States was transformational as they became self-reliant, learned their capabilities, and adapted to cultural and educational expectations. Copyright © 2011 Elsevier Inc. All rights reserved.
Delton Alderman
2013-01-01
Provides current and historical information on housing market in the United States. Information includes trends for housing permits and starts, housing completions for single and multifamily units, and sales and construction. This report will be updated annually.
Dexter, Franklin; O'Neill, Liam; Xin, Lei; Ledolter, Johannes
2008-12-01
We use resampling of data to explore the basic statistical properties of super-efficient data envelopment analysis (DEA) when used as a benchmarking tool by the manager of a single decision-making unit. Our focus is the gaps in the outputs (i.e., slacks adjusted for upward bias), as they reveal which outputs can be increased. The numerical experiments show that the estimates of the gaps fail to exhibit asymptotic consistency, a property expected for standard statistical inference. Specifically, increased sample sizes were not always associated with more accurate forecasts of the output gaps. The baseline DEA's gaps equaled the mode of the jackknife and the mode of resampling with/without replacement from any subset of the population; usually, the baseline DEA's gaps also equaled the median. The quartile deviations of gaps were close to zero when few decision-making units were excluded from the sample and the study unit happened to have few other units contributing to its benchmark. The results for the quartile deviations can be explained in terms of the effective combinations of decision-making units that contribute to the DEA solution. The jackknife can provide all the combinations contributing to the quartile deviation and only needs to be performed for those units that are part of the benchmark set. These results show that there is a strong rationale for examining DEA results with a sensitivity analysis that excludes one benchmark hospital at a time. This analysis enhances the quality of decision support using DEA estimates for the potential ofa decision-making unit to grow one or more of its outputs.
Neuronal codes for the inhibitory control of impulsive actions in the rat infralimbic cortex.
Tsutsui-Kimura, Iku; Ohmura, Yu; Izumi, Takeshi; Matsushima, Toshiya; Amita, Hidetoshi; Yamaguchi, Taku; Yoshida, Takayuki; Yoshioka, Mitsuhiro
2016-01-01
Poor impulse control is a debilitating condition observed in various psychiatric disorders and could be a risk factor for drug addiction, criminal involvement, and suicide. The rat infralimbic cortex (IL), located in the ventral portion of the medial prefrontal cortex, has been implicated in impulse control. To elucidate the neurophysiological basis of impulse control, we recorded single unit activity in the IL of a rat performing a 3-choiceserial reaction time task (3-CSRTT) and 2-choice task (2-CT), which are animal models for impulsivity. The inactivation of IL neuronal activity with an injection of muscimol (0.1 μg /side) disrupted impulse control in the 3-CSRTT. More than 60% (38/56) of isolated IL units were linked to impulse control, while approximately 30% of all units were linked to attentional function in the 3-CSRTT. To avoid confounding motor-related units with the impulse control-related units, we further conducted the 2-CT in which the animals' motor activities were restricted during recording window. More than 30% (14/44) of recorded IL units were linked to impulse control in the 2-CT. Several types of impulse control-related units were identified. Only 16% of all units were compatible with the results of the muscimol experiment, which showed a transient decline in the firing rate immediately before the release of behavioral inhibition. This is the first study to elucidate the neurophysiological basis of impulse control in the IL and to propose that IL neurons control impulsive actions in a more complex manner than previously considered. Copyright © 2015 Elsevier B.V. All rights reserved.
Multiple case study analysis of young women's experiences in high school engineering
NASA Astrophysics Data System (ADS)
Pollock, Meagan C.
At a time when engineers are in critical demand, women continue to be significantly underrepresented in engineering fields (11.7%) and degree programs (21.3%) in the United States. As a result, there is a national demand for improved K-12 STEM education and targeted efforts to improve equity and access to engineering and science careers for every underrepresented group. High school engineering has become a nascent and growing market for developers and an emergent opportunity for students across the United States to learn introductory engineering skills through strategic career pathways; however there is a disparity in participation at this level as well. Much useful research has been used to examine the problematization of underrepresentation (K Beddoes, 2011), but there is a dearth of literature that helps us to understand the experiences of young women in high school engineering. By examining the experiences of young women in high school engineering, we can learn ways to improve the curriculum, pedagogy, and environment for underrepresented groups such as females to ensure they have equitable access to these programs and are subsequently motivated to persist in engineering. Understanding the needs of marginalized groups is complex, and intersectional feminism seeks to understand gender in relation to other identities such as race, class, ethnicity, sexuality, and nationality. This theory asserts that gender alone is neither a total identity nor a universal experience, and it is thus advantageous to consider each of the intersecting layers of identity so as to not privilege a dominate group as representative of all women. Thus, to understand how female students engage with and experience engineering in grade school, it is useful to examine through the lens of gender, class, race, and sexuality, because this intersection frames much of the human experience. The purpose of this study is to examine high school females' experiences in engineering, with a goal to richly describe the diversity of experiences. A multiple case study analysis, this study answers the question: How do gender, class, race, and other components of intersectionality, influence high school females' experiences in engineering? Nine young women taking a high school engineering course in a suburban high school in Central Texas during the school year 2011-2012 volunteered to participate. The students were observed in their engineering classes for half of the spring 2012 semester, with bi-weekly interviews with the students, monthly interviews with the teacher, and a single interview with a parent of each volunteer. The nine rich case studies provide us with new stories that help prevent us from narrowing the experiences of women to a single incomplete stereotype, because these young women vary across race, socioeconomic backgrounds, and sexual orientation. Although each story is unique, there are commonalities among their experiences, including family, influence, classroom environment, biases, and beliefs. By drawing from their collective experiences in high school engineering, the findings direct us toward recommendations for educators, parents, engineering curriculum developers, designers of teacher professional development, and future research to improve equity and access for every student in engineering.
Early experience with influenza A H1N109 in an Australian intensive care unit.
Leen, Tim; Williams, Teresa A; Campbell, Lorraine; Chamberlain, Jenny; Gould, Andree; McEntaggart, Geraldine; Leslie, Gavin D
2010-08-01
Influenza is a common seasonal viral infection that affects large numbers of people. In early 2009, many people were admitted to hospitals in Mexico with severe respiratory failure following an influenza-like illness, subtyped as H1N1. An increased mortality rate was observed. By June 2009, H1N1 was upgraded to pandemic status. In June-July, Australian ICUs were experiencing increased activity due to the influenza pandemic. While hospitals implemented plans for the pandemic, the particularly heavy demand to provide critical care facilities to accommodate an influx of people with severe respiratory failure became evident and placed a great burden on provision of these services. This paper describes the initial experience (June to mid September) of the pandemic from the nursing perspective in a single Australian ICU. Patients were noted to be younger with a higher proportion of women, two of whom were pregnant. Two patients had APACHE III comorbidity. Of the 31 patients admitted during this period, three patients died in ICU and one patient died in hospital. Aerosol precautions were initiated for all patients. The requirement for single room accommodation placed enormous demands for bed management in ICU. Specific infection control procedures were developed to deal with this new pandemic influenza. Copyright 2010 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Yarnykh, V.; Korostyshevskaya, A.
2017-08-01
Macromolecular proton fraction (MPF) is a biophysical parameter describing the amount of macromolecular protons involved into magnetization exchange with water protons in tissues. MPF represents a significant interest as a magnetic resonance imaging (MRI) biomarker of myelin for clinical applications. A recent fast MPF mapping method enabled clinical translation of MPF measurements due to time-efficient acquisition based on the single-point constrained fit algorithm. However, previous MPF mapping applications utilized only 3 Tesla MRI scanners and modified pulse sequences, which are not commonly available. This study aimed to test the feasibility of MPF mapping implementation on a 1.5 Tesla clinical scanner using standard manufacturer’s sequences and compare the performance of this method between 1.5 and 3 Tesla scanners. MPF mapping was implemented on 1.5 and 3 Tesla MRI units of one manufacturer with either optimized custom-written or standard product pulse sequences. Whole-brain three-dimensional MPF maps obtained from a single volunteer were compared between field strengths and implementation options. MPF maps demonstrated similar quality at both field strengths. MPF values in segmented brain tissues and specific anatomic regions appeared in close agreement. This experiment demonstrates the feasibility of fast MPF mapping using standard sequences on 1.5 T and 3 T clinical scanners.
Bastaki, Fatma; Bizzari, Sami; Hamici, Sana; Nair, Pratibha; Mohamed, Madiha; Saif, Fatima; Malik, Ethar Mustafa; Al-Ali, Mahmoud Taleb; Hamzeh, Abdul Rezzak
2018-01-01
Congenital disorders of glycosylation (CDG) represent an expanding group of conditions that result from defects in protein and lipid glycosylation. Different subgroups of CDG display considerable clinical and genetic heterogeneity due to the highly complex nature of cellular glycosylation. This is further complicated by ethno-geographic differences in the mutational landscape of each of these subgroups. Ten Arab CDG patients from Latifa Hospital in Dubai, United Arab Emirates, were assessed using biochemical (glycosylation status of transferrin) and molecular approaches (next-generation sequencing [NGS] and Sanger sequencing). In silico tools including CADD and PolyPhen-2 were used to predict the functional consequences of uncovered mutations. In our sample of patients, five novel mutations were uncovered in the genes: MPDU1, PMM2, MAN1B1, and RFT1. In total, 9 mutations were harbored by the 10 patients in 7 genes. These are missense and nonsense mutations with deleterious functional consequences. This article integrates a single-center experience within a list of reported CDG mutations in the Arab world, accompanied by full molecular and clinical details pertaining to the studied cases. It also sheds light on potential ethnic differences that were not noted before in regards to CDG in the Arab world. © 2017 John Wiley & Sons Ltd/University College London.
Suchak, Malini; Lamica, Jacalyn
2018-01-01
Simple Summary When cats are relinquished to shelters, they frequently experience a great deal of stress. Shelters often try to control certain aspects of their environment, such as housing, to help them relax. Some cats are placed in small group rooms upon entry, whereas others are placed in single cages. There are tradeoffs to both systems. We wanted to compare the experience and outcomes of cats placed in single housing and group housing in shelters. We found that their experiences while at the shelter were similar, however single-housed cats were moved to the isolation unit more frequently than group-housed cats, which reduced their visibility to the public by pulling them off the adoption floor. Single-housed cats were also sent to the offsite location more frequently, which means they spent more time in transport than group-housed cats. Both groups were adopted at approximately the same rate and after similar lengths of time. However, the rate of return was high, especially in group-housed cats, and live release rate after return was lower than after a cat’s initial stay. More research is needed to know why this is happening and how to reduce returns after adoption. Abstract The merits of various housing options for domestic cats in shelters have been debated. However, comparisons are difficult to interpret because cats are typically not able to be randomly assigned to different housing conditions. In the current study, we attempted to address some of these issues by creating a retrospective matched cohort of cats in two housing types. Cats in group housing (GH) were matched with cats in single housing (SH) that were the same age, sex, breed, coat color, and size. Altogether we were able to find a match for 110 GH cats. We compared these two groups on several measures related to their experience at the shelter such as moves and the development of behavioral problems. We also compared these groups on outcomes including length of stay, live release, and returns after adoption. We found that while the frequency of moves was similar in both groups, SH cats were more likely to be moved to offsite facilities than GH cats. SH cats also spent a smaller proportion of time on the adoption floor. Length of stay and, live release and returns after adoption did not significantly differ across groups, however GH cats were two times as likely to be returned after adoption. Future research should look at the behavioral impacts of shelter decision-making regarding moving and management of cats in different housing systems. PMID:29443953
ERIC Educational Resources Information Center
Marshman, Emily; Singh, Chandralekha
2017-01-01
Single photon experiments involving a Mach-Zehnder interferometer can illustrate the fundamental principles of quantum mechanics, e.g., the wave-particle duality of a single photon, single photon interference, and the probabilistic nature of quantum measurement involving single photons. These experiments explicitly make the connection between the…
NASA Astrophysics Data System (ADS)
Mukminna, Halimahtus; Isnandar, Muladi
2017-09-01
Purpose of this research was to determine the contribution of student involvement in production/ service unit (X1), experience of industry practices (X2), and entrepreneurial attitude (Y) towards readiness entrepreneurship (Z) of vocational student regional Malang. The design of the study using a quantitative approach. The samples used as many as 130 respondents. Instruments used for collecting data in the form of questionnaires. Data analysis included descriptive and test of hypothesis. The result showed: that the description of data on the level of student involvement in production/ service unit, experience of industry practices, entrepreneurial attitude and entrepreneurship readiness in the high category. The contribution student involvement in production/ service unit of entrepreneurial attitude of 10.6%. The contribution experience of industry practices of entrepreneurial attitude of 17.4%. The contribution student involvement in production/ service unit and experience of industry practices simultaneously to entrepreneurial attitude of 44.1%. The contribution student involvement in production/ service unit of readiness entrepreneurship of 4%. The contribution experience of industry practices of readiness entrepreneurship of 5%. The contribution entrepreneurial attitude of readiness entrepreneurship of 16%. Finally, the contribution student involvement in production/ service unit, experience of industry practices, and entrepreneurial attitude simultaneously to readiness entrepreneurship of 50.3%.
Effect of chronic restraint stress on inhibitory gating in the auditory cortex of rats.
Ma, Lanlan; Li, Wai; Li, Sibin; Wang, Xuejiao; Qin, Ling
2017-05-01
A fundamental adaptive mechanism of auditory function is inhibitory gating (IG), which refers to the attenuation of neural responses to repeated sound stimuli. IG is drastically impaired in individuals with emotional and cognitive impairments (i.e. posttraumatic stress disorder). The objective of this study was to test whether chronic stress impairs the IG of the auditory cortex (AC). We used the standard two-tone stimulus paradigm and examined the parametric qualities of IG in the AC of rats by recording the electrophysiological signals of a single-unit and local field potential (LFP) simultaneously. The main results of this study were that most of the AC neurons showed a weaker response to the second tone than to the first tone, reflecting an IG of the repeated input. A fast negative wave of LFP showed consistent IG across the sampled AC sites, whereas a slow positive wave of LFP had less IG effect. IG was diminished following chronic restraint stress at both, the single-unit and LFP level, due to the increase in response to the second tone. This study provided new evidence that chronic stress disrupts the physiological function of the AC. Lay Summary The effects of chronic stress on IG were investigated by recording both, single-unit spike and LFP activities, in the AC of rats. In normal rats, most of the single-unit and N25 LFP activities in the AC showed an IG effect. IG was diminished following chronic restraint stress at both, the single-unit and LFP level.
Three dimensional metafilms with dual channel unit cells
Burckel, D. Bruce; Campione, Salvatore; Davids, Paul S.; ...
2017-04-04
Three-dimensional (3D) metafilms composed of periodic arrays of silicon unit cells containing single and multiple micrometer-scale vertical split ring resonators (SRRs) per unit cell were fabricated. In contrast to planar and stacked planar structures, these 3D metafilms have a thickness t ~λ d/4, allowing for classical thin film effects in the long wavelength limit. The infrared specular far-field scattering response was measured for metafilms containing one and two resonators per unit cell and compared to numerical simulations. Excellent agreement in the frequency region below the onset of diffractive scattering was obtained. For dense arrays of unit cells containing single SRRs,more » normally incident linearly polarized plane waves which do not excite a resonant response result in thin film interference fringes in the reflected spectra and are virtually indistinguishable from the scattering response of an undecorated array of unit cells. For the resonant linear polarization, the specular reflection for arrays is highly dependent on the SRR orientation on the vertical face for gap-up, gap-down, and gap-right orientations. For dense arrays of unit cells containing two SRRs per unit cell positioned on adjacent faces, the specular reflection spectra are slightly modified due to near-field coupling between the orthogonally oriented SRRs but otherwise exhibit reflection spectra largely representative of the corresponding single-SRR unit cell structures. Lastly, the ability to pack the unit cell with multiple inclusions which can be independently excited by choice of incident polarization suggests the construction of dual-channel films where the scattering response is selected by altering the incident polarization.« less
Agricultural Experiment Stations and Branch Stations in the United States
ERIC Educational Resources Information Center
Pearson, Calvin H.; Atucha, Amaya
2015-01-01
In 1887, Congress passed the Hatch Act, which formally established and provided a funding mechanism for agricultural experiment stations in each state and territory in the United States. The main purpose of agricultural experiment stations is to conduct agricultural research to meet the needs of the citizens of the United States. The objective of…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-01
...-kilowatt (kW) turbine/generator unit; and (2) an approximately 1,290-foot-long, 26-inch-diameter high...); (2) an existing structure which will house a single turbine/generator with an installed capacity of... structure which will house a single turbine/generator unit with an installed capacity of 50 kW; (3) a...
The Effects of Exercise on the Firing Patterns of Single Motor Units.
ERIC Educational Resources Information Center
Cracraft, Joe D.
In this study, the training effects of static and dynamic exercise programs on the firing patterns of 450 single motor units (SMU) in the human tibialis anterior muscle were investigated. In a six week program, the static group (N=5) participated in daily high intensity, short duration, isometric exercises while the dynamic group (N=5)…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dudka, A. P., E-mail: dudka@ns.crys.ras.ru
2017-03-15
Accurate X-ray diffraction study of langasite (La{sub 3}Ga{sub 5}SiO{sub 14}) single crystal has been performed using the data obtained on a diffractometer equipped with a CCD area detector at 295 and 90.5 K. Within the known La{sub 3}Ga{sub 5}SiO{sub 14} model, Ga and Si cations jointly occupy the 2d site. A new model of a “multicell” consisting of two different unit cells is proposed. Gallium atoms occupy the 2d site in one of these cells, and silicon atoms occupy this site in the other cell; all other atoms correspondingly coordinate these cations. This structure implements various physical properties exhibited bymore » langasite family crystals. The conclusions are based on processing four data sets obtained with a high resolution (sin θ/λ ≤ 1.35 Å{sup –1}), the results reproduced in repeated experiments, and the high relative precision of the study (sp. gr. P321, Z = 1; at 295 K, a = 8.1652(6) Å, c = 5.0958(5) Å, R/wR = 0.68/0.68%, 3927 independent reflections; at 90.5 K, a = 8.1559(4) Å, c = 5.0913(6) Å, R/wR = 0.92/0.93%, 3928 reflections).« less
NASA Astrophysics Data System (ADS)
Li, X. G.; Long, X. Y.; Jiang, H. Q.; Long, H. B.
2018-05-01
The splice is the weakest part of the entire steel cord conveyor belt. And it occurs steel cord twitch fault frequently. If this fault cannot be dealt with timely and accurately, broken belt accidents would be occurred that affecting the safety of production seriously. In this paper, we investigate the steel cord pullout of the steel cord conveyor belt splice by using ABAQUS software. We selected the strength of steel cord conveyor belt ST630, the same as experiment sample in type specification. The finite element model consists of rubber, steel cord and failure unit. And the failure unit is used to simulate the bonding relationship between the steel cord and the rubber. Mooney-Rivlin hyper-elastic model for rubber was employed in the numerical simulations. The pullout force of length 50.0 mm single steel cord, on both sides of a single steel cord and on both sides of the double steel cords each impacted at steel cord conveyor belt splice were numerically computer and typical results obtained have been validated by experimental result. It shows that the relative error between simulation results and experimental results is within 10% and can be considered that the simulation model is reliable. A new method is provided for studying the steel cord twitch fault of the steel cord conveyor belt splice.
Conducting Research on the International Space Station Using the EXPRESS Rack Facilities
NASA Technical Reports Server (NTRS)
Thompson, Sean W.; Lake, Robert E.
2013-01-01
Eight "Expedite the Processing of Experiments to Space Station" (EXPRESS) Rack facilities are located within the International Space Station (ISS) laboratories to provide standard resources and interfaces for the simultaneous and independent operation of multiple experiments within each rack. Each EXPRESS Rack provides eight Middeck Locker Equivalent locations and two drawer locations for powered experiment equipment, also referred to as sub-rack payloads. Payload developers may provide their own structure to occupy the equivalent volume of one, two, or four lockers as a single unit. Resources provided for each location include power (28 Vdc, 0-500 W), command and data handling (Ethernet, RS-422, 5 Vdc discrete, +/- 5 Vdc analog), video (NTSC/RS 170A), and air cooling (0-200 W). Each rack also provides water cooling (500 W) for two locations, one vacuum exhaust interface, and one gaseous nitrogen interface. Standard interfacing cables and hoses are provided on-orbit. One laptop computer is provided with each rack to control the rack and to accommodate payload application software. Four of the racks are equipped with the Active Rack Isolation System to reduce vibration between the ISS and the rack. EXPRESS Racks are operated by the Payload Operations Integration Center at Marshall Space Flight Center and the sub-rack experiments are operated remotely by the investigating organization. Payload Integration Managers serve as a focal to assist organizations developing payloads for an EXPRESS Rack. NASA provides EXPRESS Rack simulator software for payload developers to checkout payload command and data handling at the development site before integrating the payload with the EXPRESS Functional Checkout Unit for an end-to-end test before flight. EXPRESS Racks began supporting investigations onboard ISS on April 24, 2001 and will continue through the life of the ISS.
Conducting Research on the International Space Station using the EXPRESS Rack Facilities
NASA Technical Reports Server (NTRS)
Thompson, Sean W.; Lake, Robert E.
2016-01-01
Eight "Expedite the Processing of Experiments to Space Station" (EXPRESS) Rack facilities are located within the International Space Station (ISS) laboratories to provide standard resources and interfaces for the simultaneous and independent operation of multiple experiments within each rack. Each EXPRESS Rack provides eight Middeck Locker Equivalent locations and two drawer locations for powered experiment equipment, also referred to as sub-rack payloads. Payload developers may provide their own structure to occupy the equivalent volume of one, two, or four lockers as a single unit. Resources provided for each location include power (28 Vdc, 0-500 W), command and data handling (Ethernet, RS-422, 5 Vdc discrete, +/- 5 Vdc analog), video (NTSC/RS 170A), and air cooling (0-200 W). Each rack also provides water cooling for two locations (500W ea.), one vacuum exhaust interface, and one gaseous nitrogen interface. Standard interfacing cables and hoses are provided on-orbit. One laptop computer is provided with each rack to control the rack and to accommodate payload application software. Four of the racks are equipped with the Active Rack Isolation System to reduce vibration between the ISS and the rack. EXPRESS Racks are operated by the Payload Operations Integration Center at Marshall Space Flight Center and the sub-rack experiments are operated remotely by the investigating organization. Payload Integration Managers serve as a focal to assist organizations developing payloads for an EXPRESS Rack. NASA provides EXPRESS Rack simulator software for payload developers to checkout payload command and data handling at the development site before integrating the payload with the EXPRESS Functional Checkout Unit for an end-to-end test before flight. EXPRESS Racks began supporting investigations onboard ISS on April 24, 2001 and will continue through the life of the ISS.
Optimal load scheduling in commercial and residential microgrids
NASA Astrophysics Data System (ADS)
Ganji Tanha, Mohammad Mahdi
Residential and commercial electricity customers use more than two third of the total energy consumed in the United States, representing a significant resource of demand response. Price-based demand response, which is in response to changes in electricity prices, represents the adjustments in load through optimal load scheduling (OLS). In this study, an efficient model for OLS is developed for residential and commercial microgrids which include aggregated loads in single-units and communal loads. Single unit loads which include fixed, adjustable and shiftable loads are controllable by the unit occupants. Communal loads which include pool pumps, elevators and central heating/cooling systems are shared among the units. In order to optimally schedule residential and commercial loads, a community-based optimal load scheduling (CBOLS) is proposed in this thesis. The CBOLS schedule considers hourly market prices, occupants' comfort level, and microgrid operation constraints. The CBOLS' objective in residential and commercial microgrids is the constrained minimization of the total cost of supplying the aggregator load, defined as the microgrid load minus the microgrid generation. This problem is represented by a large-scale mixed-integer optimization for supplying single-unit and communal loads. The Lagrangian relaxation methodology is used to relax the linking communal load constraint and decompose the independent single-unit functions into subproblems which can be solved in parallel. The optimal solution is acceptable if the aggregator load limit and the duality gap are within the bounds. If any of the proposed criteria is not satisfied, the Lagrangian multiplier will be updated and a new optimal load schedule will be regenerated until both constraints are satisfied. The proposed method is applied to several case studies and the results are presented for the Galvin Center load on the 16th floor of the IIT Tower in Chicago.
A model of high-affinity antibody binding to type III group B Streptococcus capsular polysaccharide.
Wessels, M R; Muñoz, A; Kasper, D L
1987-12-01
We recently reported that the single repeating-unit pentasaccharide of type III group B Streptococcus (GBS) capsular polysaccharide is only weakly reactive with type III GBS antiserum. To further elucidate the relationship between antigen-chain length and antigenicity, tritiated oligosaccharides derived from type III capsular polysaccharide were used to generate detailed saturation binding curves with a fixed concentration of rabbit antiserum in a radioactive antigen-binding assay. A graded increase in affinity of antigen-antibody binding was seen as oligosaccharide size increased from 2.6 repeating units to 92 repeating units. These differences in affinity of antibody binding to oligosaccharides of different molecular size were confirmed by immunoprecipitation and competitive ELISA, two independent assays of antigen-antibody binding. Analysis of the saturation binding experiment indicated a difference of 300-fold in antibody-binding affinity for the largest versus the smallest tested oligosaccharides. Unexpectedly, the saturation binding values approached by the individual curves were inversely related to oligosaccharide chain length on a molar basis but equivalent on a weight basis. This observation is compatible with a model in which binding of an immunoglobulin molecule to an antigenic site on the polysaccharide facilitates subsequent binding of antibody to that antigen.
Pitman, John P.; Basavaraju, Sridhar V.; Shiraishi, Ray W.; Wilkinson, Robert; von Finckenstein, Bjorn; Lowrance, David W.; Marfin, Anthony A.; Postma, Maarten; Mataranyika, Mary; Sibinga, Cees Th. Smit
2015-01-01
BACKGROUND Few African countries separate blood donations into components; however, demand for platelets (PLTs) is increasing as regional capacity to treat causes of thrombocytopenia, including chemotherapy, increases. Namibia introduced single-donor apheresis PLT collections in 2007 to increase PLT availability while reducing exposure to multiple donors via pooling. This study describes the impact this transition had on PLT availability and safety in Namibia. STUDY DESIGN AND METHODS Annual national blood collections and PLT units issued data were extracted from a database maintained by the Blood Transfusion Service of Namibia (NAMBTS). Production costs and unit prices were analyzed. RESULTS In 2006, NAMBTS issued 771 single and pooled PLT doses from 3054 whole blood (WB) donations (drawn from 18,422 WB donations). In 2007, NAMBTS issued 486 single and pooled PLT doses from 1477 WB donations (drawn from 18,309 WB donations) and 131 single-donor PLT doses. By 2011, NAMBTS issued 837 single-donor PLT doses per year, 99.1% of all PLT units. Of 5761 WB donations from which PLTs were made in 2006 to 2011, a total of 20 (0.35%) were from donors with confirmed test results for human immunodeficiency virus or other transfusion-transmissible infections (TTIs). Of 2315 single-donor apheresis donations between 2007 and 2011, none of the 663 donors had a confirmed positive result for any pathogen. As apheresis replaced WB-derived PLTs, apheresis production costs dropped by a mean of 8.2% per year, while pooled PLT costs increased by an annual mean of 21.5%. Unit prices paid for apheresis- and WB-derived PLTs increased by 9 and 7.4% per year on average, respectively. CONCLUSION Namibia’s PLT transition shows that collections from repeat apheresis donors can reduce TTI risk and production costs. PMID:25727921
Splitting Terraced Houses Into Single Units Using Oblique Aerial Imagery
NASA Astrophysics Data System (ADS)
Dahlke, D.
2017-05-01
This paper introduces a method to subdivide complex building structures like terraced houses into single house units comparable to units available in a cadastral map. 3D line segments are detected with sub-pixel accuracy in traditional vertical true orthomosaics as well as in innovative oblique true orthomosaics and their respective surface models. Hereby high gradient strengths on roofs as well as façades are taken into account. By investigating the coplanarity and frequencies within a set of 3D line segments, individual cut lines for a building complex are found. The resulting regions ideally describe single houses and thus the object complexity is reduced for subsequent topological, semantical or geometrical considerations. For the chosen study area with 70 buidling outlines a hit rate of 80% for cut lines is achieved.
U.S. Principals’ Attitudes About and Experiences with Single-Sex Schooling
Fabes, Richard A.; Pahlke, Erin; Galligan, Kathrine; Borders, Adrienne
2015-01-01
Despite a lack of scientific evidence supporting the use of single-sex education, the number of U.S. public schools offering single-sex education has increased. However, our understanding as to why decision-makers have implemented single-sex education is lacking. To address this gap, we surveyed U.S. public-school principals and assessed their attitudes about and experiences with single-sex schooling. Sixty-seven principals from single-sex schools and 193 from coeducational schools participated. The results indicated that principals who had experience with single-sex schooling tended to have more positive attitudes about single-sex schooling, viewed it as more effective, and more often evoked gender-essentialist rationales for the use of single-sex schooling than did coeducational principals. However, both single-sex and coeducational principals noted issues with single-sex schooling. It was concluded that single-sex schooling is not a silver bullet to educational reform and that when single-sex schooling is implemented, one set of issues and problems is substituted for another. PMID:26190887
U.S. Principals' Attitudes About and Experiences with Single-Sex Schooling.
Fabes, Richard A; Pahlke, Erin; Galligan, Kathrine; Borders, Adrienne
2015-04-01
Despite a lack of scientific evidence supporting the use of single-sex education, the number of U.S. public schools offering single-sex education has increased. However, our understanding as to why decision-makers have implemented single-sex education is lacking. To address this gap, we surveyed U.S. public-school principals and assessed their attitudes about and experiences with single-sex schooling. Sixty-seven principals from single-sex schools and 193 from coeducational schools participated. The results indicated that principals who had experience with single-sex schooling tended to have more positive attitudes about single-sex schooling, viewed it as more effective, and more often evoked gender-essentialist rationales for the use of single-sex schooling than did coeducational principals. However, both single-sex and coeducational principals noted issues with single-sex schooling. It was concluded that single-sex schooling is not a silver bullet to educational reform and that when single-sex schooling is implemented, one set of issues and problems is substituted for another.
Scalable and responsive event processing in the cloud
Suresh, Visalakshmi; Ezhilchelvan, Paul; Watson, Paul
2013-01-01
Event processing involves continuous evaluation of queries over streams of events. Response-time optimization is traditionally done over a fixed set of nodes and/or by using metrics measured at query-operator levels. Cloud computing makes it easy to acquire and release computing nodes as required. Leveraging this flexibility, we propose a novel, queueing-theory-based approach for meeting specified response-time targets against fluctuating event arrival rates by drawing only the necessary amount of computing resources from a cloud platform. In the proposed approach, the entire processing engine of a distinct query is modelled as an atomic unit for predicting response times. Several such units hosted on a single node are modelled as a multiple class M/G/1 system. These aspects eliminate intrusive, low-level performance measurements at run-time, and also offer portability and scalability. Using model-based predictions, cloud resources are efficiently used to meet response-time targets. The efficacy of the approach is demonstrated through cloud-based experiments. PMID:23230164
On the role of “memory” in the analysis of behavior
Branch, Marc N.
1977-01-01
Shimp's (1976) recent paper on memory and the structure of behavior is discussed, as is the concept of memory itself. Radical behaviorism is distinguished from associationism, and behavioral accounts of experiments on short-term and long-term memory are provided. Unobservable theoretical quantities, such as rate of response, are distinguished from theoretical constructs such as memory. The logical inconsistency involved in the use of short-term memory as a “theoretical primitive” in the definition of units of behavior is explicated, and an alternative strategy for identifying units of behavior is presented. It is argued that the experimental analysis of behavior has ignored processes usually considered as memorial because many of the phenomena are irreversible. Methods for the study of transitions in single subjects should be developed more fully. Possible pitfalls associated with subscription to the term memory are listed, and it is concluded that the concept is neither required nor helpful in the analysis of behavior. PMID:16812024
Dynamic Behavior of Engineered Lattice Materials
Hawreliak, J. A.; Lind, J.; Maddox, B.; Barham, M.; Messner, M.; Barton, N.; Jensen, B. J.; Kumar, M.
2016-01-01
Additive manufacturing (AM) is enabling the fabrication of materials with engineered lattice structures at the micron scale. These mesoscopic structures fall between the length scale associated with the organization of atoms and the scale at which macroscopic structures are constructed. Dynamic compression experiments were performed to study the emergence of behavior owing to the lattice periodicity in AM materials on length scales that approach a single unit cell. For the lattice structures, both bend and stretch dominated, elastic deflection of the structure was observed ahead of the compaction of the lattice, while no elastic deformation was observed to precede the compaction in a stochastic, random structure. The material showed lattice characteristics in the elastic response of the material, while the compaction was consistent with a model for compression of porous media. The experimental observations made on arrays of 4 × 4 × 6 lattice unit cells show excellent agreement with elastic wave velocity calculations for an infinite periodic lattice, as determined by Bloch wave analysis, and finite element simulations. PMID:27321697
Design of video interface conversion system based on FPGA
NASA Astrophysics Data System (ADS)
Zhao, Heng; Wang, Xiang-jun
2014-11-01
This paper presents a FPGA based video interface conversion system that enables the inter-conversion between digital and analog video. Cyclone IV series EP4CE22F17C chip from Altera Corporation is used as the main video processing chip, and single-chip is used as the information interaction control unit between FPGA and PC. The system is able to encode/decode messages from the PC. Technologies including video decoding/encoding circuits, bus communication protocol, data stream de-interleaving and de-interlacing, color space conversion and the Camera Link timing generator module of FPGA are introduced. The system converts Composite Video Broadcast Signal (CVBS) from the CCD camera into Low Voltage Differential Signaling (LVDS), which will be collected by the video processing unit with Camera Link interface. The processed video signals will then be inputted to system output board and displayed on the monitor.The current experiment shows that it can achieve high-quality video conversion with minimum board size.
[Vertebroplasty: state of the art].
Chiras, J; Barragán-Campos, H M; Cormier, E; Jean, B; Rose, M; LeJean, L
2007-09-01
Over the last 10 years, there has been much development in the management of metastatic and osteoporotic vertebral compression fractures using vertebroplasty. This percutaneous image-guided interventional radiology procedure allows stabilization of a vertebral body by injection of an acrylic cement and frequently results in significant symptomatic relief. During cement polymerisation, an exothermic reaction may destroy adjacent tumor cells. Advances have been made to reduce complications from extravasation of cement in veins or surrounding soft tissues. Safety relates to experience but also to technical parameters: optimal cement radio-density, adequate digital fluoroscopy unit (single or bi-plane digital angiography unit), development of cements other than PMMA to avoid the risk of adjacent vertebral compression fractures. The rate of symptomatic relief from vertebroplasty performed for its principal indications (vertebral hemangioma, metastases, osteoporotic fractures) reaches 90-95%. The rate of complications is about 2% for metastases and less than 0.5% for osteoporotic fractures. Vertebroplasty plays a major role in the management of specific bone weakening vertebral lesions causing, obviating the need for kyphoplasty.
Professional figures in intermediate intensive units.
Quadri, A; Simoni, P; Clini, E; Errera, D; Foglio, K; Vitacca, M; Schena, M
1994-12-01
In Italy, respiratory intermediate intensive care units (IICUs) are not yet considered as autonomous hospital departments. The IICU of the Rehabilitation Department of the Medical Centre of Gussago (12 monitored beds) provides care for respiratory and cardiac patients. Ventilatory assistance and noninvasive modalities both in treatment and monitoring suggest a multidisciplinary approach to the patient. Highly professional figures should, therefore, be singled out to provide care in a respiratory IICU. The medical staff is composed of one anaesthesiologist, one cardiologist and one pulmonologist, who can integrate care when respiratory complications occur in a cardiological patient, or when cardiac events affect a respiratory patient. Nurses are capable of specific activities, especially when ventilatory assistance is required. The presence of a physiotherapist reduces the nursing workload, especially for ventilated individuals. The psychological aspect is undertaken by a specialist. Finally, an expert in nutrition provides an individualized dietary regimen. Our 4 year experience encourages such a multidisciplinary approach. An ideal integration of the professional activities should provide adequate and individual care for patients admitted to an IICU.
Learning effect and test-retest variability of pulsar perimetry.
Salvetat, Maria Letizia; Zeppieri, Marco; Parisi, Lucia; Johnson, Chris A; Sampaolesi, Roberto; Brusini, Paolo
2013-03-01
To assess Pulsar Perimetry learning effect and test-retest variability (TRV) in normal (NORM), ocular hypertension (OHT), glaucomatous optic neuropathy (GON), and primary open-angle glaucoma (POAG) eyes. This multicenter prospective study included 43 NORM, 38 OHT, 33 GON, and 36 POAG patients. All patients underwent standard automated perimetry and Pulsar Contrast Perimetry using white stimuli modulated in phase and counterphase at 30 Hz (CP-T30W test). The learning effect and TRV for Pulsar Perimetry were assessed for 3 consecutive visual fields (VFs). The learning effect were evaluated by comparing results from the first session with the other 2. TRV was assessed by calculating the mean of the differences (in absolute value) between retests for each combination of single tests. TRV was calculated for Mean Sensitivity, Mean Defect, and single Mean Sensitivity for each 66 test locations. Influence of age, VF eccentricity, and loss severity on TRV were assessed using linear regression analysis and analysis of variance. The learning effect was not significant in any group (analysis of variance, P>0.05). TRV for Mean Sensitivity and Mean Defect was significantly lower in NORM and OHT (0.6 ± 0.5 spatial resolution contrast units) than in GON and POAG (0.9 ± 0.5 and 1.0 ± 0.8 spatial resolution contrast units, respectively) (Kruskal-Wallis test, P=0.04); however, the differences in NORM among age groups was not significant (Kruskal-Wallis test, P>0.05). Slight significant differences were found for the single Mean Sensitivity TRV among single locations (Duncan test, P<0.05). For POAG, TRV significantly increased with decreasing Mean Sensitivity and increasing Mean Defect (linear regression analysis, P<0.01). The Pulsar Perimetry CP-T30W test did not show significant learning effect in patients with standard automated perimetry experience. TRV for global indices was generally low, and was not related to patient age; it was only slightly affected by VF defect eccentricity, and significantly influenced by VF loss severity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kahlenberg, Volker; Konzett, Juergen; Kaindl, Reinhard
High-pressure synthesis experiments in the system Na{sub 2}O-Y{sub 2}O{sub 3}-SiO{sub 2} revealed the existence of a previously unknown polymorph of NaYSi{sub 2}O{sub 6} or Na{sub 3}Y{sub 3}[Si{sub 3}O{sub 9}]{sub 2} which was quenched from 3.0 GPa and 1000 deg. C. Structural investigations on this modification have been performed using single-crystal X-ray diffraction data collected at ambient conditions. Furthermore, unpolarized micro-Raman spectra have been obtained from single-crystal material. The high-P modification of NaYSi{sub 2}O{sub 6} crystallizes in the centrosymmetric space group C2/c with 12 formula units per cell (a=8.2131(9) A, b=10.3983(14) A, c=17.6542(21) A, {beta}=100.804(9){sup o}, V=1481.0(3) A{sup 3}, R(|F|)=0.033 formore » 1142 independent observed reflections) and belongs to the group of cyclo-silicates. Basic building units are isolated three-membered [Si{sub 3}O{sub 9}] rings located in layers parallel to (010). Within a single layer the rings are concentrated in strings parallel to [100]. The sequence of directedness of up (U) or down (D) pointing tetrahedra of a single ring is UUU or DDD, respectively. Stacking of the layers parallel to b results in the formation of a three-dimensional structure in which yttrium and sodium cations are incorporated for charge compensation. In more detail, four non-tetrahedral cation positions can be differentiated which are coordinated by 6 and 8 oxygen ligands. Refinements of the site occupancies did not reveal any indication for mixed Na-Y populations on these positions. Finally, several geometrical parameters of rings occurring in cyclo-trisilicate structures have been compiled and are discussed. - Graphical abstract: Projection of the whole structure of high-P NaYSi{sub 2}O{sub 6} parallel to [100].« less
NASA Technical Reports Server (NTRS)
Stanturf, J. A.; Heimbuch, D. G.
1980-01-01
A refinement to the matrix approach to environmental impact assessment is to use landscape units in place of separate environmental elements in the analysis. Landscape units can be delineated by integrating remotely sensed data and available single-factor data. A remote sensing approach to landscape stratification is described and the conditions under which it is superior to other approaches that require single-factor maps are indicated. Flowcharts show the steps necessary to develop classification criteria, delineate units and a map legend, and use the landscape units in impact assessment. Application of the approach to assessing impacts of a transmission line in Montana is presented to illustrate the method.
Simulation and parametric study of a film-coated controlled-release pharmaceutical.
Borgquist, Per; Zackrisson, Gunnar; Nilsson, Bernt; Axelsson, Anders
2002-04-23
Pharmaceutical formulations can be designed as Multiple Unit Systems, such as Roxiam CR, studied in this work. The dose is administrated as a capsule, which contains about 100 individual pellets, which in turn contain the active drug remoxipride. Experimental data for a large number of single pellets can be obtained by studying the release using microtitre plates. This makes it possible to study the release of the individual subunits making up the total dose. A mathematical model for simulating the release of remoxipride from single film-coated pellets is presented including internal and external mass transfer hindrance apart from the most important film resistance. The model can successfully simulate the release of remoxipride from single film-coated pellets if the lag phase of the experimental data is ignored. This was shown to have a minor influence on the release rate. The use of the present model is demonstrated by a parametric study showing that the release process is film-controlled, i.e. is limited by the mass transport through the polymer coating. The model was used to fit the film thickness and the drug loading to the experimental release data. The variation in the fitted values was similar to that obtained in the experiments.
Servel, A-C; Rideau Batista Novais, A
2016-09-01
The quality of the environment is an essential point in the care of preterm newborns. The design of neonatal intensive care units (NICUs) (open-bay, single-patient room, single-family room) directly affects both the preterm newborns and their caregivers (parents, healthcare staff). The aim of this systematic review was to evaluate the impact of single-family rooms on the preterm newborn, its parents, and the staff. Single-family rooms improve outcome for the preterm newborn, with increasing parental involvement and better control of the environment (fewer inappropriate stimulations such as high levels of noise and illumination). This kind of NICU design also improves parental and staff satisfaction. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arena, Lois
The U.S. Department of Energy’s Building America research team Consortium for Advanced Residential Buildings (CARB) worked with the EcoVillage cohousing community in Ithaca, New York, on the Third Residential EcoVillage Experience neighborhood. This communityscale project consists of 40 housing units—15 apartments and 25 single-family residences. Units range in size from 450 ft2 to 1,664 ft2 and cost from $80,000 for a studio apartment to $235,000 for a three- or four-bedroom single-family home. For the research component of this project, CARB analyzed current heating system sizing methods for superinsulated homes in cold climates to determine if changes in building load calculationmore » methodology should be recommended. Actual heating energy use was monitored and compared to results from the Air Conditioning Contractors of America’s Manual J8 (MJ8) and the Passive House Planning Package software. Results from that research indicate that MJ8 significantly oversizes heating systems for superinsulated homes and that thermal inertia and internal gains should be considered for more accurate load calculations.« less
Towards constructing multi-bit binary adder based on Belousov-Zhabotinsky reaction
NASA Astrophysics Data System (ADS)
Zhang, Guo-Mao; Wong, Ieong; Chou, Meng-Ta; Zhao, Xin
2012-04-01
It has been proposed that the spatial excitable media can perform a wide range of computational operations, from image processing, to path planning, to logical and arithmetic computations. The realizations in the field of chemical logical and arithmetic computations are mainly concerned with single simple logical functions in experiments. In this study, based on Belousov-Zhabotinsky reaction, we performed simulations toward the realization of a more complex operation, the binary adder. Combining with some of the existing functional structures that have been verified experimentally, we designed a planar geometrical binary adder chemical device. Through numerical simulations, we first demonstrated that the device can implement the function of a single-bit full binary adder. Then we show that the binary adder units can be further extended in plane, and coupled together to realize a two-bit, or even multi-bit binary adder. The realization of chemical adders can guide the constructions of other sophisticated arithmetic functions, ultimately leading to the implementation of chemical computer and other intelligent systems.
High Sensitivity Refractometer Based on Reflective Smf-Small Diameter No Core Fiber Structure.
Zhou, Guorui; Wu, Qiang; Kumar, Rahul; Ng, Wai Pang; Liu, Hao; Niu, Longfei; Lalam, Nageswara; Yuan, Xiaodong; Semenova, Yuliya; Farrell, Gerald; Yuan, Jinhui; Yu, Chongxiu; Zeng, Jie; Tian, Gui Yun; Fu, Yong Qing
2017-06-16
A high sensitivity refractive index sensor based on a single mode-small diameter no core fiber structure is proposed. In this structure, a small diameter no core fiber (SDNCF) used as a sensor probe, was fusion spliced to the end face of a traditional single mode fiber (SMF) and the end face of the SDNCF was coated with a thin film of gold to provide reflective light. The influence of SDNCF diameter and length on the refractive index sensitivity of the sensor has been investigated by both simulations and experiments, where results show that the diameter of SDNCF has significant influence. However, SDNCF length has limited influence on the sensitivity. Experimental results show that a sensitivity of 327 nm/RIU (refractive index unit) has been achieved for refractive indices ranging from 1.33 to 1.38, which agrees well with the simulated results with a sensitivity of 349.5 nm/RIU at refractive indices ranging from 1.33 to 1.38.
Xiong, Wenjuan; Du, Lili; Lo, Kin Cheung; Shi, Haiting; Takaya, Tomohisa; Iwata, Koichi; Chan, Wai Kin; Phillips, David Lee
2018-06-25
Conjugated polymers incorporated with cycloplatinated complexes (P1-Pt and P2-Pt) were used as dispersants for single walled carbon nanotubes (SWCNTs). Significant changes in the UV-vis absorption spectra were observed after the formation of the polymer/SWCNT hybrids. Molecular dynamics (MD) simulations revealed the presence of a strong interaction between the cycloplatinated complex moieties and the SWCNT surface. The photoinduced electron transfer processes in these hybrids were strongly dependent on the type of the comonomer unit. Upon photoexcitation, the excited P1-Pt donates electrons to the SWCNT, while P2-Pt accepts electrons from the photoexcited SWCNT. These observations were supported by results from Raman and femtosecond time-resolved transient absorption spectroscopy experiments. The strong electronic interaction between the Pt complexes and the SWCNT gives rise to a new hybrid system that has a controllable photo-induced electron transfer flow, which are important in regulating the charge transport processes SWCNT-based optoelectronic devices.
NASA Astrophysics Data System (ADS)
Pandey, Arun; Bandyopadhyay, M.; Sudhir, Dass; Chakraborty, A.
2017-10-01
Helicon wave heated plasmas are much more efficient in terms of ionization per unit power consumed. A permanent magnet based compact helicon wave heated plasma source is developed in the Institute for Plasma Research, after carefully optimizing the geometry, the frequency of the RF power, and the magnetic field conditions. The HELicon Experiment for Negative ion-I source is the single driver helicon plasma source that is being studied for the development of a large sized, multi-driver negative hydrogen ion source. In this paper, the details about the single driver machine and the results from the characterization of the device are presented. A parametric study at different pressures and magnetic field values using a 13.56 MHz RF source has been carried out in argon plasma, as an initial step towards source characterization. A theoretical model is also presented for the particle and power balance in the plasma. The ambipolar diffusion process taking place in a magnetized helicon plasma is also discussed.
Serial snapshot crystallography for materials science with SwissFEL
Dejoie, Catherine; Smeets, Stef; Baerlocher, Christian; ...
2015-04-21
New opportunities for studying (sub)microcrystalline materials with small unit cells, both organic and inorganic, will open up when the X-ray free electron laser (XFEL) presently being constructed in Switzerland (SwissFEL) comes online in 2017. Our synchrotron-based experiments mimicking the 4%-energy-bandpass mode of the SwissFEL beam show that it will be possible to record a diffraction pattern of up to 10 randomly oriented crystals in a single snapshot, to index the resulting reflections, and to extract their intensities reliably. The crystals are destroyed with each XFEL pulse, but by combining snapshots from several sets of crystals, a complete set of datamore » can be assembled, and crystal structures of materials that are difficult to analyze otherwise will become accessible. Even with a single shot, at least a partial analysis of the crystal structure will be possible, and with 10–50 femtosecond pulses, this offers tantalizing possibilities for time-resolved studies.« less
Pandey, Arun; Bandyopadhyay, M; Sudhir, Dass; Chakraborty, A
2017-10-01
Helicon wave heated plasmas are much more efficient in terms of ionization per unit power consumed. A permanent magnet based compact helicon wave heated plasma source is developed in the Institute for Plasma Research, after carefully optimizing the geometry, the frequency of the RF power, and the magnetic field conditions. The HELicon Experiment for Negative ion-I source is the single driver helicon plasma source that is being studied for the development of a large sized, multi-driver negative hydrogen ion source. In this paper, the details about the single driver machine and the results from the characterization of the device are presented. A parametric study at different pressures and magnetic field values using a 13.56 MHz RF source has been carried out in argon plasma, as an initial step towards source characterization. A theoretical model is also presented for the particle and power balance in the plasma. The ambipolar diffusion process taking place in a magnetized helicon plasma is also discussed.
Cheng, Zheng Ze; Mao, Xue Song; Gong, Rong Zhou
2017-01-01
We design an ultra-thin multi-band polarization-insensitive metamaterial absorber (MMA) using a single circular sector resonator (CSR) structure in the microwave region. Simulated results show that the proposed MMA has three distinctive absorption peaks at 3.35 GHz, 8.65 GHz, and 12.44 GHz, with absorbance of 98.8%, 99.7%, and 98.3%, respectively, which agree well with an experiment. Simulated surface current distributions of the unit-cell structure reveal that the triple-band absorption mainly originates from multiple-harmonic magnetic resonance. The proposed triple-band MMA can remain at a high absorption level for all polarization of both transverse-electric (TE) and transverse-magnetic (TM) modes under normal incidence. Moreover, by further optimizing the geometric parameters of the CSRs, four-band and five-band MMAs can also be obtained. Thus, our design will have potential application in detection, sensing, and stealth technology. PMID:29077036
Schmid, G P
1999-01-01
Since the 1993 treatment guidelines for sexually transmitted diseases were published by the Centers for Disease Control and Prevention, experience has indicated that the regimens recommended then remain largely effective. The recommended therapies--with azithromycin (1 g orally, once), ceftriaxone (250 mg intramuscularly, once), or erythromycin (500 mg orally, four times a day for 7 days)--appear highly effective in the United States; limited data from Kenya suggest that the ceftriaxone regimen may not be as effective there as it once was. The alternative regimen of ciprofloxacin proposed in 1993 (500 mg orally, twice a day for 3 days) is as effective as the recommended therapies, but new information indicates that single-dose therapy with 500 mg orally is not as effective as the use of either larger single doses or more prolonged therapy. Persons who are infected with human immunodeficiency virus (HIV) do not respond as well as those who are not HIV-infected, and males who are uncircumcised appear not to respond as well as those who are circumcised.
Haupert, M L; Gesselman, Amanda N; Moors, Amy C; Fisher, Helen E; Garcia, Justin R
2017-07-04
Although academic and popular interest in consensual nonmonogamy (CNM) is increasing, little is known about the prevalence of CNM. Using two separate U.S. Census based quota samples of single adults in the United States (Study 1: n = 3,905; Study 2: n = 4,813), the present studies show that more than one in five (21.9% in Study 1; 21.2% in Study 2) participants report engaging in CNM at some point in their lifetime. This proportion remained constant across age, education level, income, religion, region, political affiliation, and race, but varied with gender and sexual orientation. Specifically, men (compared to women) and people who identify as gay, lesbian, or bisexual (compared to those who identify as heterosexual) were more likely to report previous engagement in CNM. These findings suggest that a sizable and diverse proportion of U.S. adults have experienced CNM, highlighting the need to incorporate CNM into theoretical and empirical therapy and family science work.
Jacchia, Sara; Nardini, Elena; Savini, Christian; Petrillo, Mauro; Angers-Loustau, Alexandre; Shim, Jung-Hyun; Trijatmiko, Kurniawan; Kreysa, Joachim; Mazzara, Marco
2015-02-18
In this study, we developed, optimized, and in-house validated a real-time PCR method for the event-specific detection and quantification of Golden Rice 2, a genetically modified rice with provitamin A in the grain. We optimized and evaluated the performance of the taxon (targeting rice Phospholipase D α2 gene)- and event (targeting the 3' insert-to-plant DNA junction)-specific assays that compose the method as independent modules, using haploid genome equivalents as unit of measurement. We verified the specificity of the two real-time PCR assays and determined their dynamic range, limit of quantification, limit of detection, and robustness. We also confirmed that the taxon-specific DNA sequence is present in single copy in the rice genome and verified its stability of amplification across 132 rice varieties. A relative quantification experiment evidenced the correct performance of the two assays when used in combination.
Johnson, Miriam J; Kanaan, Mona; Richardson, Gerry; Nabb, Samantha; Torgerson, David; English, Anne; Barton, Rachael; Booth, Sara
2015-09-07
About 90 % of patients with intra-thoracic malignancy experience breathlessness. Breathing training is helpful, but it is unknown whether repeated sessions are needed. The present study aims to test whether three sessions are better than one for breathlessness in this population. This is a multi-centre randomised controlled non-blinded parallel arm trial. Participants were allocated to three sessions or single (1:2 ratio) using central computer-generated block randomisation by an independent Trials Unit and stratified for centre. The setting was respiratory, oncology or palliative care clinics at eight UK centres. Inclusion criteria were people with intrathoracic cancer and refractory breathlessness, expected prognosis ≥3 months, and no prior experience of breathing training. The trial intervention was a complex breathlessness intervention (breathing training, anxiety management, relaxation, pacing, and prioritisation) delivered over three hour-long sessions at weekly intervals, or during a single hour-long session. The main primary outcome was worst breathlessness over the previous 24 hours ('worst'), by numerical rating scale (0 = none; 10 = worst imaginable). Our primary analysis was area under the curve (AUC) 'worst' from baseline to 4 weeks. All analyses were by intention to treat. Between April 2011 and October 2013, 156 consenting participants were randomised (52 three; 104 single). Overall, the 'worst' score reduced from 6.81 (SD, 1.89) to 5.84 (2.39). Primary analysis [n = 124 (79 %)], showed no between-arm difference in the AUC: three sessions 22.86 (7.12) vs single session 22.58 (7.10); P value = 0.83); mean difference 0.2, 95 % CIs (-2.31 to 2.97). Complete case analysis showed a non-significant reduction in QALYs with three sessions (mean difference -0.006, 95 % CIs -0.018 to 0.006). Sensitivity analyses found similar results. The probability of the single session being cost-effective (threshold value of £20,000 per QALY) was over 80 %. There was no evidence that three sessions conferred additional benefits, including cost-effectiveness, over one. A single session of breathing training seems appropriate and minimises patient burden. Registry: ISRCTN; ISRCTN49387307; http://www.isrctn.com/ISRCTN49387307 ; registration date: 25/01/2011.
NASA Technical Reports Server (NTRS)
Rietmeijer, F. J. M.
1989-01-01
Olivine-rich chondritic interplanetary dust particles (IDPs) are an important subset of fluffy chondritic IDPs collected in the earth's stratosphere. Particles in this subset are characterized by a matrix of nonporous, ultrafine-grained granular units. Euhedral single crystals, crystals fragments, and platey single crystals occur dispersed in the matrix. Analytical electron microscopy of granular units reveals predominant magnesium-rich olivines and FeNi-sulfides embedded in amorphous carbonaceous matrix material. The variable ratio of ultrafine-grained minerals vs. carbonaceous matrix material in granular units support variable C/Si ratios, and some fraction of sulfur is associated with carbonaceous matrix material. The high Mg/(Mg+Fe) ratios in granular units is similar to this distribution in P/Comet Halley dust. The chondritic composition of fine-grained, polycrystalline IDPs gradually breaks down into nonchondritic, and ultimately, single mineral compositions as a function of decreased particle mass. The relationship between particle mass and composition in the matrix of olivine-rich chondritic IDPs is comparable with the relationship inferred for P/Comet Halley dust.
Thermal protection systems manned spacecraft flight experience
NASA Technical Reports Server (NTRS)
Curry, Donald M.
1992-01-01
Since the first U.S. manned entry, Mercury (May 5, 1961), seventy-five manned entries have been made resulting in significant progress in the understanding and development of Thermal Protection Systems (TPS) for manned rated spacecraft. The TPS materials and systems installed on these spacecraft are compared. The first three vehicles (Mercury, Gemini, Apollo) used ablative (single-use) systems while the Space Shuttle Orbiter TPS is a multimission system. A TPS figure of merit, unit weight lb/sq ft, illustrates the advances in TPS material performance from Mercury (10.2 lb/sq ft) to the Space Shuttle (1.7 lb/sq ft). Significant advances have been made in the design, fabrication, and certification of TPS on manned entry vehicles (Mercury through Shuttle Orbiter). Shuttle experience has identified some key design and operational issues. State-of-the-art ceramic insulation materials developed in the 1970's for the Space Shuttle Orbiter have been used in the initial designs of aerobrakes. This TPS material experience has identified the need to develop a technology base from which a new class of higher temperature materials will emerge for advanced space transportation vehicles.
Organisational culture and learning: a case study.
Bell, Elaine
2013-11-01
To explore the impact organisational cultures have on the learning experience of student nurses and identify the influencing factors. A case study approach was used. The single case being a Defence School of Health Care Studies (DSHCS) and the multiple units of analysis: student nurses, the lecturers and Student Standing Orders. An in depth three dimensional picture was achieved using multiple data collection methods: interview, survey, observation and document analysis. The findings suggest that the DSHCS is perceived to be a sub-culture within a dominant civilian learning culture. Generally, the students and staff believed that the DSHCS is an excellent learning environment and that the defence students overall are high achievers. The common themes that appeared from the data were image, ethos, environment, discipline, support, welfare and a civilian versus military way of thinking. The learning experience of defence student nurses is very positive and enhanced by the positive learning culture of the civilian Higher Educational Institution. The factors influencing a positive learning experience that can be impacted by the overarching culture are discipline, image, ethos of adult learning, support and welfare. Copyright © 2013 Elsevier Ltd. All rights reserved.
Leprosy and stigma in the context of international migration.
White, Cassandra
2011-06-01
If it can be argued that no single attribute or condition (leprosy included) is inherently or universally considered to be 'deeply discrediting,' to quote Goffman, then we must consider how external factors shape stigma associated with that condition in different cultural and socioeconomic contexts. Often, an analysis of what is perceived to be stigma towards people affected by leprosy uncovers other prejudices or stigmatising attitudes associated with class, gender, and/or ethnic inequalities in that society. The movement of people across international borders adds new dimensions to the experience of leprosy, as affected individuals confront different sets of understandings of the disease among healthcare professionals, friends, family, and employers in host and sending countries. Preconceptions of the immigrant 'other' in host countries may be bound up with notions of disease and danger, further complicating the experience of leprosy treatment for immigrants. Drawing on the work of others and on early stage qualitative research on leprosy among Brazilian immigrants to the United States, this paper will consider the ways in which immigration and transnational processes could affect the experience of stigma among immigrants affected by leprosy.
Mountain Plains Learning Experience Guide: Automotive Repair. Course: Emission Systems.
ERIC Educational Resources Information Center
Schramm, C.; Osland, Walt
One of twelve individualized courses included in an automotive repair curriculum, this course covers the theory, testing, and servicing of automotive emission control systems. The course is comprised of one unit, Fundamentals of Emission Systems. The unit begins with a Unit Learning Experience Guide that gives directions for unit completion. The…
Cheng, Jian; Deriche, Rachid; Jiang, Tianzi; Shen, Dinggang; Yap, Pew-Thian
2014-11-01
Spherical Deconvolution (SD) is commonly used for estimating fiber Orientation Distribution Functions (fODFs) from diffusion-weighted signals. Existing SD methods can be classified into two categories: 1) Continuous Representation based SD (CR-SD), where typically Spherical Harmonic (SH) representation is used for convenient analytical solutions, and 2) Discrete Representation based SD (DR-SD), where the signal profile is represented by a discrete set of basis functions uniformly oriented on the unit sphere. A feasible fODF should be non-negative and should integrate to unity throughout the unit sphere S(2). However, to our knowledge, most existing SH-based SD methods enforce non-negativity only on discretized points and not the whole continuum of S(2). Maximum Entropy SD (MESD) and Cartesian Tensor Fiber Orientation Distributions (CT-FOD) are the only SD methods that ensure non-negativity throughout the unit sphere. They are however computational intensive and are susceptible to errors caused by numerical spherical integration. Existing SD methods are also known to overestimate the number of fiber directions, especially in regions with low anisotropy. DR-SD introduces additional error in peak detection owing to the angular discretization of the unit sphere. This paper proposes a SD framework, called Non-Negative SD (NNSD), to overcome all the limitations above. NNSD is significantly less susceptible to the false-positive peaks, uses SH representation for efficient analytical spherical deconvolution, and allows accurate peak detection throughout the whole unit sphere. We further show that NNSD and most existing SD methods can be extended to work on multi-shell data by introducing a three-dimensional fiber response function. We evaluated NNSD in comparison with Constrained SD (CSD), a quadratic programming variant of CSD, MESD, and an L1-norm regularized non-negative least-squares DR-SD. Experiments on synthetic and real single-/multi-shell data indicate that NNSD improves estimation performance in terms of mean difference of angles, peak detection consistency, and anisotropy contrast between isotropic and anisotropic regions. Copyright © 2014 Elsevier Inc. All rights reserved.
Distractor ratio and grouping processes in visual conjunction search.
Poisson, M E; Wilkinson, F
1992-01-01
According to feature integration theory, conjunction search is conducted via a serial self-terminating search. However, effects attributed to search processes operating on the entire display may actually reflect search restricted to elements defined by a single feature. In experiment 1 this question is addressed in a reaction-time (RT) paradigm by varying distractor ratios within an array of fixed size. For trials in which the target was present in the array, RT functions were roughly symmetric, the shortest RTs being for extreme distractor ratios, and the longest RTs being for arrays in which there were an equal number of each distractor type. This result is superficially consistent with Zohary and Hochstein's interpretation that subjects search for only one distractor type and are able to switch search strategy from trial to trial. However, negative-trial data from experiment 1 case doubt on this interpretation. In experiment 2 the possible role of 'pop out' and of distractor grouping in visual conjunction search is investigated. Results of experiment 2 suggest that grouping may play a more important role than does distractor ratio, and point to the importance of the spatial layout of the target and of the distractor elements in visual conjunction search. Results of experiment 2 also provide clear evidence that groups of spatially adjacent homogeneous elements may be processed as a unit.
The Critical Mass Laboratory at Rocky Flats
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rothe, Robert E
2003-10-15
The Critical Mass Laboratory (CML) at Rocky Flats northwest of Denver, Colorado, was built in 1964 and commissioned to conduct nuclear experiments on January 28, 1965. It was built to attain more accurate and precise experimental data to ensure nuclear criticality safety at the plant than were previously possible. Prior to its construction, safety data were obtained from long extrapolations of subcritical data (called in situ experiments), calculated parameters from reactor engineering 'models', and a few other imprecise methods. About 1700 critical and critical-approach experiments involving several chemical forms of enriched uranium and plutonium were performed between then and 1988.more » These experiments included single units and arrays of fissile materials, reflected and 'bare' systems, and configurations with various degrees of moderation, as well as some containing strong neutron absorbers. In 1989, a raid by the Federal Bureau of Investigation (FBI) caused the plant as a whole to focus on 'resumption' instead of further criticality safety experiments. Though either not recognized or not admitted for a few years, that FBI raid did sound the death knell for the CML. The plant's optimistic goal of resumption evolved to one of deactivation, decommissioning, and plantwide demolition during the 1990s. The once-proud CML facility was finally demolished in April of 2002.« less
NASA Astrophysics Data System (ADS)
Finneran, James J.; Carder, Donald A.; Ridgway, Sam H.
2002-01-01
The relative contributions of acoustic pressure and particle velocity to the low-frequency, underwater hearing abilities of the bottlenose dolphin (Tursiops truncatus) and white whale (Delphinapterus leucas) were investigated by measuring (masked) hearing thresholds while manipulating the relationship between the pressure and velocity. This was accomplished by varying the distance within the near field of a single underwater sound projector (experiment I) and using two underwater sound projectors and an active sound control system (experiment II). The results of experiment I showed no significant change in pressure thresholds as the distance between the subject and the sound source was changed. In contrast, velocity thresholds tended to increase and intensity thresholds tended to decrease as the source distance decreased. These data suggest that acoustic pressure is a better indicator of threshold, compared to particle velocity or mean active intensity, in the subjects tested. Interpretation of the results of experiment II (the active sound control system) was difficult because of complex acoustic conditions and the unknown effects of the subject on the generated acoustic field; however, these data also tend to support the results of experiment I and suggest that odontocete thresholds should be reported in units of acoustic pressure, rather than intensity.
Liu, Chengtang; Mu, Yujing; Zhang, Chenglong; Zhang, Zhibo; Zhang, Yuanyuan; Liu, Junfeng; Sheng, Jiujiang; Quan, Jiannong
2016-01-04
A liquid nitrogen-free GC-FID system equipped with a single column has been developed for measuring atmospheric C2-C12 hydrocarbons. The system is consisted of a cooling unit, a sampling unit and a separation unit. The cooling unit is used to meet the temperature needs of the sampling unit and the separation unit. The sampling unit includes a dehydration tube and an enrichment tube. No breakthrough of the hydrocarbons was detected when the temperature of the enrichment tube was kept at -90 °C and sampling volume was 400 mL. The separation unit is a small round oven attached on the cooling column. A single capillary column (OV-1, 30 m × 0.32 mm I.D.) was used to separate the hydrocarbons. An optimal program temperature (-60 ∼ 170 °C) of the oven was achieved to efficiently separate C2-C12 hydrocarbons. There were good linear correlations (R(2)=0.993-0.999) between the signals of the hydrocarbons and the enrichment amount of hydrocarbons, and the relative standard deviation (RSD) was less than 5%, and the method detection limits (MDLs) for the hydrocarbons were in the range of 0.02-0.10 ppbv for sampling volume of 400 mL. Field measurements were also conducted and more than 50 hydrocarbons from C2 to C12 were detected in Beijing city. Copyright © 2015 Elsevier B.V. All rights reserved.
Volkán-Kacsó, Sándor; Marcus, Rudolph A
2016-10-25
A recently proposed chemomechanical group transfer theory of rotary biomolecular motors is applied to treat single-molecule controlled rotation experiments. In these experiments, single-molecule fluorescence is used to measure the binding and release rate constants of nucleotides by monitoring the occupancy of binding sites. It is shown how missed events of nucleotide binding and release in these experiments can be corrected using theory, with F 1 -ATP synthase as an example. The missed events are significant when the reverse rate is very fast. Using the theory the actual rate constants in the controlled rotation experiments and the corrections are predicted from independent data, including other single-molecule rotation and ensemble biochemical experiments. The effective torsional elastic constant is found to depend on the binding/releasing nucleotide, and it is smaller for ADP than for ATP. There is a good agreement, with no adjustable parameters, between the theoretical and experimental results of controlled rotation experiments and stalling experiments, for the range of angles where the data overlap. This agreement is perhaps all the more surprising because it occurs even though the binding and release of fluorescent nucleotides is monitored at single-site occupancy concentrations, whereas the stalling and free rotation experiments have multiple-site occupancy.
Atomic force microscopy reveals the mechanical design of a modular protein
Li, Hongbin; Oberhauser, Andres F.; Fowler, Susan B.; Clarke, Jane; Fernandez, Julio M.
2000-01-01
Tandem modular proteins underlie the elasticity of natural adhesives, cell adhesion proteins, and muscle proteins. The fundamental unit of elastic proteins is their individually folded modules. Here, we use protein engineering to construct multimodular proteins composed of Ig modules of different mechanical strength. We examine the mechanical properties of the resulting tandem modular proteins by using single protein atomic force microscopy. We show that by combining modules of known mechanical strength, we can generate proteins with novel elastic properties. Our experiments reveal the simple mechanical design of modular proteins and open the way for the engineering of elastic proteins with defined mechanical properties, which can be used in tissue and fiber engineering. PMID:10823913
Atomic force microscopy reveals the mechanical design of a modular protein.
Li, H; Oberhauser, A F; Fowler, S B; Clarke, J; Fernandez, J M
2000-06-06
Tandem modular proteins underlie the elasticity of natural adhesives, cell adhesion proteins, and muscle proteins. The fundamental unit of elastic proteins is their individually folded modules. Here, we use protein engineering to construct multimodular proteins composed of Ig modules of different mechanical strength. We examine the mechanical properties of the resulting tandem modular proteins by using single protein atomic force microscopy. We show that by combining modules of known mechanical strength, we can generate proteins with novel elastic properties. Our experiments reveal the simple mechanical design of modular proteins and open the way for the engineering of elastic proteins with defined mechanical properties, which can be used in tissue and fiber engineering.
NASA Technical Reports Server (NTRS)
Kiceniuk, T.
1985-01-01
An organic Rankine-cycle (ORC) power module was developed for use in a multimodule solar power plant to be built and operated in a small community. Many successful components and subsystems, including the reciever, power conversion subsystem, energy transport subsystem, and control subsystem, were tested. Tests were performed on a complete power module using a test bed concentrator in place of the proposed concentrator. All major single-module program functional objectives were met and the multimodule operation presented no apparent problems. The hermetically sealed, self-contained, ORC power conversion unit subsequently successfully completed a 300-hour endurance run with no evidence of wear or operating problems.
ERIC Educational Resources Information Center
Simpson, Amber; Che, S. Megan
2016-01-01
Utilizing a descriptive phenomenological design, this study examines the lived experiences of seven middle grade students, four females and three males, enrolled in a single-sex mathematics classroom within a coeducational school setting. The intent of the study is to understand, from students themselves, about the experience of single-sex…
ERIC Educational Resources Information Center
Wang, Miao; Ngai, Steven Sek-Yum
2011-01-01
Using data collected by the Organization for Economic Co-operation and Development's Program for International Student Assessment in 2003, this study examines the gap in the educational aspirations of children from single-parent families and two-parent families in the United Kingdom (UK) and Hong Kong. Consistent with previous research on the…
Experience with 850-MW fossil-fired units in peaking service
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dixon, B.G.
1978-01-01
Experience with the peaking operation of two 850-MW gross generation units at the Martins Creek Steam Electric Station in Pennsylvania is described. The design, operation, and performance of these oil-fueled units are discussed. (LCL)
Atmospheric Science Data Center
2016-11-25
United Arab Emirates - Unified Aerosol Experiment (UAE 2 ) 2004 The United Arab Emirates-Unified Aerosol Experiment (UAE2) 2004 field campaign scheduled ... 2004 targets the coastal and desert regions of the United Arab Emirates. The main scientific goal is to evaluate and improve satellite ...
United States housing, first quarter 2013
Delton Alderman
2014-01-01
Provides current and historical information on housing market in the United States. Information includes trends for housing permits and starts, housing under construction, and housing completions for single and multifamily units, and sales and construction. This report will be updated regularly.
Cap, Andrew P; Pidcoke, Heather F; Keil, Shawn D; Staples, Hilary M; Anantpadma, Manu; Carrion, Ricardo; Davey, Robert A; Frazer-Abel, Ashley; Taylor, Audra L; Gonzales, Richard; Patterson, Jean L; Goodrich, Raymond P
2016-03-01
Transfusion of plasma from recovered patients after Ebolavirus (EBOV) infection, typically called "convalescent plasma," is an effective treatment for active disease available in endemic areas, but carries the risk of introducing other pathogens, including other strains of EBOV. A pathogen reduction technology using ultraviolet light and riboflavin (UV+RB) is effective against multiple enveloped, negative-sense, single-stranded RNA viruses that are similar in structure to EBOV. We hypothesized that UV+RB is effective against EBOV in blood products without activating complement or reducing protective immunoglobulin titers that are important for the treatment of Ebola virus disease (EVD). Four in vitro experiments were conducted to evaluate effects of UV+RB on green fluorescent protein EBOV (EBOV-GFP), wild-type EBOV in serum, and whole blood, respectively, and on immunoglobulins and complement in plasma. Initial titers for Experiments 1 to 3 were 4.21 log GFP units/mL, 4.96 log infectious units/mL, and 4.23 log plaque-forming units/mL. Conditions tested in the first three experiments included the following: 1-EBOV-GFP plus UV+RB; 2-EBOV-GFP plus RB only; 3-EBOV-GFP plus UV only; 4-EBOV-GFP without RB or UV; 5-virus-free control plus UV only; and 6-virus-free control without RB or UV. UV+RB reduced EBOV titers to nondetectable levels in both nonhuman primate serum (≥2.8- to 3.2-log reduction) and human whole blood (≥3.0-log reduction) without decreasing protective antibody titers in human plasma. Our in vitro results demonstrate that the UV+RB treatment efficiently reduces EBOV titers to below limits of detection in both serum and whole blood. In vivo testing to determine whether UV+RB can improve convalescent blood product safety is indicated. © 2016 AABB.
Cap, Andrew P.; Pidcoke, Heather F.; Keil, Shawn D.; Staples, Hilary M.; Anantpadma, Manu; Carrion, Ricardo; Davey, Robert A.; Frazer-Abel, Ashley; Taylor, Audra L.; Gonzales, Richard; Patterson, Jean L.; Goodrich, Raymond P.
2018-01-01
BACKGROUND Transfusion of plasma from recovered patients after Ebolavirus (EBOV) infection, typically called ‘convalescent plasma,’ is an effective treatment for active disease available in endemic areas, but carries the risk of introducing other pathogens, including other strains of EBOV. A pathogen reduction technology using ultraviolet light and riboflavin (UV + RB) is effective against multiple enveloped, negative-sense, single-stranded RNA viruses that are similar in structure to EBOV. We hypothesized that UV + RB is effective against EBOV in blood products without activating complement or reducing protective immunoglobulin titers that are important for the treatment of ebolavirus disease (EVD). STUDY DESIGN AND METHODS Four in vitro experiments were conducted to evaluate effects of UV + RB on green fluorescent protein EBOV (EBOV-GFP), wild-type EBOV in serum and whole blood, respectively, and on immunoglobulins and complement in plasma. Initial titers for Experiments 1–3 were: 4.21 log10 GFP units/mL, 4.96 log10 infectious units per mL, and 4.23 log10 plaque forming units per mL (PFU/mL). Conditions tested in the first three experiments included: 1. EBOV-GFP + UV + RB; 2. EBOV-GFP + RB only; 3 EBOV-GFP + UV only; 4. EBOV-GFP without RB or UV; 5. Virus-free control + UV only; and 6. Virus-free control without RB or UV. RESULTS UV + RB reduced EBOV titers to non-detectable levels in both non-human primate serum (≥ 2.8 to 3.2 log reduction) and human whole blood (≥ 3.0 log reduction) without decreasing protective antibody titers in human plasma. CONCLUSION Our in vitro results demonstrate that the UV + RB treatment efficiently reduces EBOV titers to below limits of detection in both serum and whole blood. In vivo testing to determine whether UV + RB can improve convalescent blood product safety is indicated. PMID:27001363
Ia Afferent input alters the recruitment thresholds and firing rates of single human motor units.
Grande, G; Cafarelli, E
2003-06-01
Vibration of the patellar tendon recruits motor units in the knee extensors via excitation of muscle spindles and subsequent Ia afferent input to the alpha-motoneuron pool. Our first purpose was to determine if the recruitment threshold and firing rate of the same motor unit differed when recruited involuntarily via reflex or voluntarily via descending spinal pathways. Although Ia input is excitatory to the alpha-motoneuron pool, it has also been shown paradoxically to inhibit itself. Our second purpose was to determine if vibration of the patellar tendon during a voluntary knee extension causes a change in the firing rate of already recruited motor units. In the first protocol, 10 subjects voluntarily reproduced the same isometric force profile of the knee extensors that was elicited by vibration of the patellar tendon. Single motor unit recordings from the vastus lateralis (VL) were obtained with tungsten microelectrodes and unitary behaviour was examined during both reflex and voluntary knee extensions. Recordings from 135 single motor units showed that both recruitment thresholds and firing rates were lower during reflex contractions. In the second protocol, 7 subjects maintained a voluntary knee extension at 30 N for approximately 40-45 s. Three bursts of patellar tendon vibration were superimposed at regular intervals throughout the contraction and changes in the firing rate of already recruited motor units were examined. A total of 35 motor units were recorded and each burst of superimposed vibration caused a momentary reduction in the firing rates and recruitment of additional units. Our data provide evidence that Ia input modulates the recruitment thresholds and firing rates of motor units providing more flexibility within the neuromuscular system to grade force at low levels of force production.
Challenges to validity in single-group interrupted time series analysis.
Linden, Ariel
2017-04-01
Single-group interrupted time series analysis (ITSA) is a popular evaluation methodology in which a single unit of observation is studied; the outcome variable is serially ordered as a time series, and the intervention is expected to "interrupt" the level and/or trend of the time series, subsequent to its introduction. The most common threat to validity is history-the possibility that some other event caused the observed effect in the time series. Although history limits the ability to draw causal inferences from single ITSA models, it can be controlled for by using a comparable control group to serve as the counterfactual. Time series data from 2 natural experiments (effect of Florida's 2000 repeal of its motorcycle helmet law on motorcycle fatalities and California's 1988 Proposition 99 to reduce cigarette sales) are used to illustrate how history biases results of single-group ITSA results-as opposed to when that group's results are contrasted to those of a comparable control group. In the first example, an external event occurring at the same time as the helmet repeal appeared to be the cause of a rise in motorcycle deaths, but was only revealed when Florida was contrasted with comparable control states. Conversely, in the second example, a decreasing trend in cigarette sales prior to the intervention raised question about a treatment effect attributed to Proposition 99, but was reinforced when California was contrasted with comparable control states. Results of single-group ITSA should be considered preliminary, and interpreted with caution, until a more robust study design can be implemented. © 2016 John Wiley & Sons, Ltd.
Consentius, Philipp; Gohlke, Ulrich; Loll, Bernhard; Alings, Claudia; Heinemann, Udo; Wahl, Markus C; Risse, Thomas
2017-08-09
Electron paramagnetic resonance (EPR) spectroscopy in combination with site-directed spin labeling is used to investigate the structure and dynamics of conformationally constrained spin labels in T4 lysozyme single crystals. Within a single crystal, the oriented ensemble of spin bearing moieties results in a strong angle dependence of the EPR spectra. A quantitative description of the EPR spectra requires the determination of the unit cell orientation with respect to the sample tube and the orientation of the spin bearing moieties within the crystal lattice. Angle dependent EPR spectra were analyzed by line shape simulations using the stochastic Liouville equation approach developed by Freed and co-workers and an effective Hamiltonian approach. The gain in spectral information obtained from the EPR spectra of single crystalline samples taken at different frequencies, namely the X-band and Q-band, allows us to discriminate between motional models describing the spectra of isotropic solutions similarly well. In addition, it is shown that the angle dependent single crystal spectra allow us to identify two spin label rotamers with very similar side chain dynamics. These results demonstrate the utility of single crystal EPR spectroscopy in combination with spectral line shape simulation techniques to extract valuable dynamic information not readily available from the analysis of isotropic systems. In addition, it will be shown that the loss of electron density in high resolution diffraction experiments at room temperature does not allow us to conclude that there is significant structural disorder in the system.
MAGNETOMETER - TRI-AXIS SENSOR UNIT - GEMINI-TITAN (GT)-12 EXPERIMENT MSC-3 (M405) - MSC
1966-10-01
S66-09379 (1 Oct. 1966) --- Tri-Axis Magnetometer-Sensor Unit mounted on telescoping boom. Cable connects Sensor Unit with Electronics Unit mounted on retrograde beam in retrograde adapter section. Objective of experiment is to monitor the direction and amplitude of Earth's magnetic field (Gemini-12). Photo credit: NASA
NASA Astrophysics Data System (ADS)
Wohland, Thorsten
2015-06-01
Single Molecule Detection and Spectroscopy have grown from their first beginnings into mainstream, mature research areas that are widely applied in the biological sciences. However, despite the advances in technology and the application of many single molecule techniques even in in vivo settings, the data analysis of single molecule experiments is complicated by noise, systematic errors, and complex underlying processes that are only incompletely understood. Colomb and Sarkar provide in this issue an overview of single molecule experiments and the accompanying problems in data analysis, which have to be overcome for a proper interpretation of the experiments [1].
Paleointensity results for 0 and 4 ka from Hawaiian lava flows: a new approach to sampling
NASA Astrophysics Data System (ADS)
Cromwell, G.; Tauxe, L.; Staudigel, H.; Ron, H.; Trusdell, F.
2012-04-01
Paleointensity data are typically generated from core samples drilled out of the massive parts of lava flows. During Thellier-Thellier type experiments, these massive samples suffer from very low success rates (~20%), as shown by failure to meet statistical criteria. Low success generally occurs for two reasons: 1) alteration of the sample during the heating process, and 2) multi-domain behavior of massive material. Moreover, recent studies of historical lava flows show that massive samples may not accurately reflect the intensity of the magnetic field even when they are successful (Valet et al., 2010). Alternatively, submarine basaltic glasses (SBG) produce high success rates (~80%) for Thellier-Thellier type experiments, likely due to near instantaneous cooling rates which produce single-domain magnetic grains. In addition, SBG have been proven to produce accurate records of the magnetic field (e.g., Pick and Tauxe, 1993). In this study we investigate the success of paleointensity experiments on subaerial quenched basalts from Hawaii in the quest for single domain, rapidly cooled subaerial analogs to SBG. We also examine the effects of grain size and cooling rate on the accuracy of paleointensity results. During March 2011, we collected samples from 31 dated lava flows (0-3800 BP), including the historical 1950 C.E. and 2010 C.E. flows. Each lava flow was additionally subsampled when unique cooling structures within the unit could be identified. Single-domain, rapidly quenched glasses from the 1950 and 2010 flows are ideally behaved, i.e. straight Arai plots, and accurately record the expected geomagnetic field strength. However, slower cooled specimens from the same flows produce sagged Arai plots and consistently underestimate expected geomagnetic field intensity. Results from ideally behaved glasses over the last 4 ka indicate periods of rapid field change in Hawaii and a possible high intensity field spike around 2.7 ka. We will present new results from our comprehensive data set of Hawaii paleointensity on about the last 4 ka.
Magnetic susceptibility well-logging unit with single power supply thermoregulation system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seeley, R. L.
1985-11-05
The magnetic susceptibility well-logging unit with single power supply thermoregulation system provides power from a single surface power supply over a well-logging cable to an integrated circuit voltage regulator system downhole. This voltage regulator system supplies regulated voltages to a temperature control system and also to a Maxwell bridge sensing unit which includes the solenoid of a magnetic susceptibility probe. The temperature control system is provided with power from the voltage regulator system and operates to permit one of several predetermined temperatures to be chosen, and then operates to maintain the solenoid of a magnetic susceptibility probe at this chosenmore » temperature. The temperature control system responds to a temperature sensor mounted upon the probe solenoid to cause resistance heaters concentrically spaced from the probe solenoid to maintain the chosen temperature. A second temperature sensor on the probe solenoid provides a temperature signal to a temperature transmitting unit, which initially converts the sensed temperature to a representative voltage. This voltage is then converted to a representative current signal which is transmitted by current telemetry over the well logging cable to a surface electronic unit which then reconverts the current signal to a voltage signal.« less
Single phase space laundry development
NASA Technical Reports Server (NTRS)
Colombo, Gerald V.; Putnam, David F.; Lunsford, Teddie D.; Streech, Neil D.; Wheeler, Richard R., Jr.; Reimers, Harold
1993-01-01
This paper describes a newly designed, 2.7 Kg (6 pound) capacity, laundry machine called the Single Phase Laundry (SPSL). The machine was designed to wash and dry crew clothing in a micro-gravity environment. A prototype unit was fabricated for NASA-JSC under a Small Business Innovated Research (SBIR) contract extending from September 1990 to January 1993. The unit employs liquid jet agitation, microwave vacuum drying, and air jet tumbling, which was perfected by KC-135 zero-g flight testing. Operation is completely automated except for loading and unloading clothes. The unit uses about 20 percent less power than a conventional household appliance.
Extracting Models in Single Molecule Experiments
NASA Astrophysics Data System (ADS)
Presse, Steve
2013-03-01
Single molecule experiments can now monitor the journey of a protein from its assembly near a ribosome to its proteolytic demise. Ideally all single molecule data should be self-explanatory. However data originating from single molecule experiments is particularly challenging to interpret on account of fluctuations and noise at such small scales. Realistically, basic understanding comes from models carefully extracted from the noisy data. Statistical mechanics, and maximum entropy in particular, provide a powerful framework for accomplishing this task in a principled fashion. Here I will discuss our work in extracting conformational memory from single molecule force spectroscopy experiments on large biomolecules. One clear advantage of this method is that we let the data tend towards the correct model, we do not fit the data. I will show that the dynamical model of the single molecule dynamics which emerges from this analysis is often more textured and complex than could otherwise come from fitting the data to a pre-conceived model.
Ishioka, Noriaki; Suzuki, Hiromi; Asashima, Makoto; Kamisaka, Seiichiro; Mogami, Yoshihiro; Ochiai, Toshimasa; Aizawa-Yano, Sachiko; Higashibata, Akira; Ando, Noboru; Nagase, Mutsumu; Ogawa, Shigeyuki; Shimazu, Toru; Fukui, Keiji; Fujimoto, Nobuyoshi
2004-03-01
Japan Aerospace Exploration Agency (JAXA) has developed a cell biology experiment facility (CBEF) and a clean bench (CB) as a common hardware in which life science experiments in the Japanese Experiment Module (JEM known as "Kibo") of the International Space Station (ISS) can be performed. The CBEF, a CO2 incubator with a turntable that provides variable gravity levels, is the basic hardware required to carry out the biological experiments using microorganisms, cells, tissues, small animals, plants, etc. The CB provides a closed aseptic operation area for life science and biotechnology experiments in Kibo. A phase contrast and fluorescence microscope is installed inside CB. The biological experiment units (BEU) are designed to run individual experiments using the CBEF and the CB. A plant experiment unit (PEU) and two cell experiment units (CEU type1 and type2) for the BEU have been developed.
Perspectives of physicians and nurses regarding end-of-life care in the intensive care unit.
Festic, Emir; Wilson, Michael E; Gajic, Ognjen; Divertie, Gavin D; Rabatin, Jeffrey T
2012-02-01
The delivery of end-of-life care (EOLC) in the intensive care unit (ICU) varies widely among medical care providers. The differing opinions of nurses and physicians regarding EOLC may help identify areas of improvement. To explore the differences of physicians and nurses on EOLC in the ICU and how these differences vary according to self-reported proficiency level and primary work unit. Cross-sectional survey of 69 ICU physicians and 629 ICU nurses. Single tertiary care academic medical institution. A total of 50 physicians (72%) and 331 nurses (53%) participated in the survey. Significant differences between physicians and nurses were noted in the following areas: ability to safely raise concerns, do not resuscitate (DNR) decision making, discussion of health care directives, timely hospice referral, spiritual assessment documentation, utilization of social services, and the availability of EOLC education. In every domain of EOLC, physicians reported a more positive perception than nurses. Additional differences were noted among physicians based on experience, as well as among nurses based on their primary work unit and self-reported proficiency level. Even with an increased focus on improving EOLC, significant differences continue to exist between the perspectives of nurses and physicians, as well as physicians among themselves and nurses among themselves. These differences may represent significant barriers toward providing comprehensive, consistent, and coordinated EOLC in the ICU.
Benzies, Karen M; Shah, Vibhuti; Aziz, Khalid; Lodha, Abhay; Misfeldt, Renée
2018-05-11
To describe the perspectives of health care providers and hospital administrators on their experiences of providing care for infants in Level II neonatal intensive care units and their families. We conducted 36 qualitative interviews with neonatal health care providers and hospital administrators and analysed data using a descriptive interpretive approach. 10 Level II Neonatal Intensive Care Units in a single, integrated health care system in one Canadian province. Three major themes emerged: (1) providing family-centred care, (2) working amidst health care system challenges, and (3) recommending improvements to the health care system. The overarching theme was that the health care system was making 'too much noise' for health care providers and hospital administrators to provide family-centred care in ways that would benefit infants and their families. Recommended improvements included: refining staffing models, enhancing professional development, providing tools to deliver consistent care, recognising parental capacity to be involved in care, strengthening continuity of care, supporting families to be with their infant, and designing family-friendly environments. When implementing family-centred care initiatives, health care providers and hospital administrators need to consider the complexity of providing care in Level II Neonatal Intensive Care Units, and recognise that health care system changes may be necessary to optimise implementation. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
NASA Astrophysics Data System (ADS)
Yurgens, A.; You, L. X.; Torstensson, M.; Winkler, D.
2007-09-01
We describe experiments which are only possible through an ultimate control of sample shape and dimensions down to nanometer scale whereby transport measurements can be done in various restricted geometries. We use photolithography patterning together with a flip-chip technique to isolate very thin (d ∼ 100 nm) pieces of Bi2Sr2CaCu2O8+δ (BSCCO) single crystals. Ar-ion milling allows us to further thin these crystals down to a few nanometers in a controlled way. With decreasing thickness below two to three unit cells, the superconducting transition temperature gradually decreases to zero and the in-plane resistivity increases to large values indicating the existence of a superconductor-insulator transition in these ultrathin single crystals. In a refined technique, a precise control of the etching depth from both sides of the crystal makes it possible to form stacks of intrinsic Josephson junctions (IJJs) inside the ultrathin single crystals. The stacks can be tailor-made to any microscopic height (0-9 nm < d), i.e. enclosing a specific number of IJJs (0-6). In certain geometries, by feeding current into the topmost Cu2O4-layer of a mesa on the surface of a BSCCO single crystal, we measured the critical value of this current by detecting a sharp upturn or break in the current-voltage characteristics. From this, we estimate the sheet critical current density of a single Cu2O4 plane to be ∼0.3-0.7 A/cm at 4.5 K, corresponding to a bulk current density of ∼2-5 MA/cm2. These values are among the largest ever reported for BSCCO single crystals, thin-films and tapes.
The Fractions SNARC Revisited: Processing Fractions on a Consistent Mental Number Line.
Toomarian, Elizabeth Y; Hubbard, Edward M
2017-07-12
The ability to understand fractions is key to establishing a solid foundation in mathematics, yet children and adults struggle to comprehend them. Previous studies have suggested that these struggles emerge because people fail to process fraction magnitude holistically on the mental number line (MNL), focusing instead on fraction components (Bonato et al. 2007). Subsequent studies have produced evidence for default holistic processing (Meert et al., 2009; 2010), but examined only magnitude processing, not spatial representations. We explored the spatial representations of fractions on the MNL in a series of three experiments: Experiment 1 replicated Bonato et al. (2007); 30 naïve undergraduates compared unit fractions (1/1-1/9) to 1/5, resulting in a reverse SNARC effect. Experiment 2 countered potential strategic biases induced by the limited set of fractions used by Bonato et al. by expanding the stimulus set to include all irreducible, single-digit proper fractions, and asked participants to compare them against 1/2. We observed a classic SNARC effect, completely reversing the pattern from Experiment 1. Together, Experiments 1 and 2 demonstrate that stimulus properties dramatically impact spatial representations of fractions. In Experiment 3, we demonstrated within-subjects reliability of the SNARC effect across both a fractions and whole number comparison task. Our results suggest that adults can indeed process fraction magnitudes holistically, and that their spatial representations occur on a consistent MNL for both whole numbers and fractions.
NASA Technical Reports Server (NTRS)
Byers, M. S.
1973-01-01
Analyses for Experiment M555, Gallium Arsenide Single Crystal Growth (MSFC), to be used for evaluating the performance of the Skylab corollary experiments under preflight, inflight, and post-flight conditions are presented. Experiment contingency plan workaround procedure and malfunction analyses are presented in order to assist in making the experiment operationally successful.
Fraction-storage unit for drug-identification system
NASA Technical Reports Server (NTRS)
Campen, C. F.; Stuart, J. L.
1976-01-01
Device, connecting outputs of all gas chromatographs to single, relatively inexpensive IR spectrometer, reduces costs of system. Storage unit provides buffer storage of samples until infrared spectrometer is ready to accept them. Storage unit can be used to separate overlapping peaks.
46 CFR 181.450 - Independent modular smoke detecting units.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Independent modular smoke detecting units. 181.450... Independent modular smoke detecting units. (a) An independent modular smoke detecting unit must: (1) Meet UL 217 (incorporated by reference, see 46 CFR 175.600) and be listed as a “Single Station Smoke detector...
46 CFR 181.450 - Independent modular smoke detecting units.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false Independent modular smoke detecting units. 181.450... Independent modular smoke detecting units. (a) An independent modular smoke detecting unit must: (1) Meet UL 217 (incorporated by reference, see 46 CFR 175.600) and be listed as a “Single Station Smoke detector...
46 CFR 181.450 - Independent modular smoke detecting units.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Independent modular smoke detecting units. 181.450... Independent modular smoke detecting units. (a) An independent modular smoke detecting unit must: (1) Meet UL 217 (incorporated by reference, see 46 CFR 175.600) and be listed as a “Single Station Smoke detector...
46 CFR 181.450 - Independent modular smoke detecting units.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Independent modular smoke detecting units. 181.450... Independent modular smoke detecting units. (a) An independent modular smoke detecting unit must: (1) Meet UL 217 (incorporated by reference, see 46 CFR 175.600) and be listed as a “Single Station Smoke detector...
46 CFR 181.450 - Independent modular smoke detecting units.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Independent modular smoke detecting units. 181.450... Independent modular smoke detecting units. (a) An independent modular smoke detecting unit must: (1) Meet UL 217 (incorporated by reference, see 46 CFR 175.600) and be listed as a “Single Station Smoke detector...
Asymmetric top-down modulation of ascending visual pathways in pigeons.
Freund, Nadja; Valencia-Alfonso, Carlos E; Kirsch, Janina; Brodmann, Katja; Manns, Martina; Güntürkün, Onur
2016-03-01
Cerebral asymmetries are a ubiquitous phenomenon evident in many species, incl. humans, and they display some similarities in their organization across vertebrates. In many species the left hemisphere is associated with the ability to categorize objects based on abstract or experience-based behaviors. Using the asymmetrically organized visual system of pigeons as an animal model, we show that descending forebrain pathways asymmetrically modulate visually evoked responses of single thalamic units. Activity patterns of neurons within the nucleus rotundus, the largest thalamic visual relay structure in birds, were differently modulated by left and right hemispheric descending systems. Thus, visual information ascending towards the left hemisphere was modulated by forebrain top-down systems at thalamic level, while right thalamic units were strikingly less modulated. This asymmetry of top-down control could promote experience-based processes within the left hemisphere, while biasing the right side towards stimulus-bound response patterns. In a subsequent behavioral task we tested the possible functional impact of this asymmetry. Under monocular conditions, pigeons learned to discriminate color pairs, so that each hemisphere was trained on one specific discrimination. Afterwards the animals were presented with stimuli that put the hemispheres in conflict. Response patterns on the conflicting stimuli revealed a clear dominance of the left hemisphere. Transient inactivation of left hemispheric top-down control reduced this dominance while inactivation of right hemispheric top-down control had no effect on response patterns. Functional asymmetries of descending systems that modify visual ascending pathways seem to play an important role in the superiority of the left hemisphere in experience-based visual tasks. Copyright © 2015. Published by Elsevier Ltd.
Garratt-Reed, David; Roberts, Lynne D; Heritage, Brody
2016-01-01
There has been a recent rapid growth in the number of psychology courses offered online through institutions of higher education. The American Psychological Association has highlighted the importance of ensuring the effectiveness of online psychology courses (Halonen et al., 2013). Despite this, there have been inconsistent findings regarding student grades, satisfaction, and retention in online psychology units. Equivalency Theory (Simonson, 1999; Simonson et al., 1999) posits that online and classroom-based learners will attain equivalent learning outcomes when equivalent learning experiences are provided. We present a study of an online introductory psychology unit designed to provide equivalent learning experiences to the pre-existing face-to-face version of the unit. Using quasi-experimental methods, academic performance, student feedback, and retention data from 866 Australian undergraduate psychology students were examined to assess whether the online unit developed to provide equivalent learning experiences produced comparable outcomes to the 'traditional' unit delivered face-to-face. Student grades did not significantly differ between modes of delivery, except for a group-work based assessment where online students performed more poorly. Student satisfaction was generally high in both modes of the unit, with group-work the key source of dissatisfaction in the online unit. The results provide partial support for Equivalency Theory. The group-work based assessment did not provide an equivalent learning experience for students in the online unit highlighting the need for further research to determine effective methods of engaging students in online group activities. Consistent with previous research, retention rates were significantly lower in the online unit, indicating the need to develop effective strategies to increase online retention rates. While this study demonstrates successes in presenting students with an equivalent learning experience, we recommend that future research investigate means of successfully facilitating collaborative group-work assessment, and to explore contributing factors to actual student retention in online units beyond that of non-equivalent learning experiences.
Garratt-Reed, David; Roberts, Lynne D.; Heritage, Brody
2016-01-01
There has been a recent rapid growth in the number of psychology courses offered online through institutions of higher education. The American Psychological Association has highlighted the importance of ensuring the effectiveness of online psychology courses (Halonen et al., 2013). Despite this, there have been inconsistent findings regarding student grades, satisfaction, and retention in online psychology units. Equivalency Theory (Simonson, 1999; Simonson et al., 1999) posits that online and classroom-based learners will attain equivalent learning outcomes when equivalent learning experiences are provided. We present a study of an online introductory psychology unit designed to provide equivalent learning experiences to the pre-existing face-to-face version of the unit. Using quasi-experimental methods, academic performance, student feedback, and retention data from 866 Australian undergraduate psychology students were examined to assess whether the online unit developed to provide equivalent learning experiences produced comparable outcomes to the ‘traditional’ unit delivered face-to-face. Student grades did not significantly differ between modes of delivery, except for a group-work based assessment where online students performed more poorly. Student satisfaction was generally high in both modes of the unit, with group-work the key source of dissatisfaction in the online unit. The results provide partial support for Equivalency Theory. The group-work based assessment did not provide an equivalent learning experience for students in the online unit highlighting the need for further research to determine effective methods of engaging students in online group activities. Consistent with previous research, retention rates were significantly lower in the online unit, indicating the need to develop effective strategies to increase online retention rates. While this study demonstrates successes in presenting students with an equivalent learning experience, we recommend that future research investigate means of successfully facilitating collaborative group-work assessment, and to explore contributing factors to actual student retention in online units beyond that of non-equivalent learning experiences. PMID:27242587
ERIC Educational Resources Information Center
Bush, Dana I.
2012-01-01
There are 26 single-purpose nursing programs in the United States. They are nursing programs operated by hospitals with the single purpose of supplying the hospitals with well-prepared health care staff. Using a quantitative methodology and an ex post facto design, this study compared employment retention rates between single-purpose and…
Degradable conjugated polymers for the selective sorting of semiconducting carbon nanotubes
Gopalan, Padma; Arnold, Michael Scott; Kansiusarulsamy, Catherine Kanimozhi; Brady, Gerald Joseph; Shea, Matthew John
2018-04-10
Conjugated polymers composed of bi-pyridine units linked to 9,9-dialkyl fluorenyl-2,7-diyl units via imine linkages along the polymer backbone are provided. Also provided are semiconducting single-walled carbon nanotubes coated with the conjugated polymers and methods of sorting and separating s-SWCNTs from a sample comprising a mixture of s-SWCNTs and metallic single-walled carbon nanotubes using the conjugated polymers.
Development of Driver/Vehicle Steering Interaction Models for Dynamic Analysis
1988-12-01
Figure 5-10. The Linearized Single-Unit Vehicle Model ............................... 41 Figure 5-11. Interpretation of the Single-Unit Model...The starting point for the driver modelling research conducted under this project was a linear preview control model originally proposed by MacAdam 1...regardless of its origin, can pass at least the elementary validation test of exhibiting "cross-over model"-like- behavior in the vicinity of its
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rutter, Charles E., E-mail: charles.rutter@yale.edu; Yale Cancer Center, New Haven, Connecticut; Yu, James B.
2015-03-01
Purpose: To characterize temporal trends in the application of various bone metastasis fractionations within the United States during the past decade, using the National Cancer Data Base; the primary aim was to determine whether clinical practice in the United States has changed over time to reflect the published randomized evidence and the growing movement for value-based treatment decisions. Patients and Methods: The National Cancer Data Base was used to identify patients treated to osseous metastases from breast, prostate, and lung cancer. Utilization of single-fraction versus multiple-fraction radiation therapy was compared according to demographic, disease-related, and health care system details. Results: Wemore » included 24,992 patients treated during the period 2005-2011 for bone metastases. Among patients treated to non-spinal/vertebral sites (n=9011), 4.7% received 8 Gy in 1 fraction, whereas 95.3% received multiple-fraction treatment. Over time the proportion of patients receiving a single fraction of 8 Gy increased (from 3.4% in 2005 to 7.5% in 2011). Numerous independent predictors of single-fraction treatment were identified, including older age, farther travel distance for treatment, academic treatment facility, and non-private health insurance (P<.05). Conclusions: Single-fraction palliative radiation therapy regimens are significantly underutilized in current practice in the United States. Further efforts are needed to address this issue, such that evidence-based and cost-conscious care becomes more commonplace.« less
NASA Astrophysics Data System (ADS)
Merlini, M.
2013-12-01
The recent improvements at synchrotron beamlines, currently allow single crystal diffraction experiments at extreme pressures and temperatures [1,2] on very small single crystal domains. We successfully applied such technique to determine the crystal structure adopted by carbonates at mantle pressures. The knowledge of carbon-bearing phases is in fact fundamental for any quantitative modelling of global carbon cycle. The major technical difficulty arises after first order transitions or decomposition reactions, since original crystal (apx. 10x10x5 μm3) is transformed in much smaller crystalline domains often with random orientation. The use of 3D reciprocal space visualization software and the improved resolution of new generation flat panel detectors, however, allow both identification and integration of each single crystal domain, with suitable accuracy for ab-initio structure solution, performed with direct and charge-flipping methods and successive structure refinements. The results obtained on carbonates, indicate two major crystal-chemistry trends established at high pressures. The CO32- units, planar and parallel in ambient pressure calcite and dolomite structures, becomes non parallel in calcite- and dolomite-II and III phases, allowing more flexibility in the structures with possibility to accommodate strain arising from different cation sizes (Ca and Mg in particular). Dolomite-III is therefore also observed to be thermodynamically stable at lower mantle pressures and temperatures, differently from dolomite, which undergoes decomposition into pure end-members in upper mantle. At higher pressure, towards Mbar (lowermost mantle and D'' region) in agreement with theoretical calculations [3,4] and other experimental results [5], carbon coordination transform into 4-fold CO4 units, with different polymerisation in the structure depending on carbonate composition. The second important crystal chemistry feature detected is related to Fe2+ in Fe-bearing magnesite, which spontaneously oxidises at HP/HT, forming Fe3+ carbonates, Fe3+ oxides and reduced carbon (diamonds). Single crystal diffraction approach allowed full structure determination of these phases, yielding to the discovery of few unpredicted structures, such as Mg2Fe2C4O13 and Fe13O19, which can be well reproduced in different experiments. Mg2Fe2C4O13 carbonate present truncated chain C4O13 groups, and Fe13O19 oxide, whose stoichiometry is intermediate between magnetite and hematite, is a one-layer structure, with features encountered in superconducting materials. The results fully support the ideas of unexpected complexities in the mineralogy of the lowermost mantle, and single crystal technique, once properly optimized in ad-hoc synchrotron beamlines, is fundamental for extracting accurate structural information, otherwise rarely accessible with other experimental techniques. References: [1] Merlini M., Hanfland M. (2013). Single crystal diffraction at Mbar conditions by synchrotron radiation. High Pressure Research, in press. [2] Dubrovinsky et al., (2010). High Pressure Research, 30, 620-633. [3] Arapan et al. (1997). Phys. Rev. Lett., 98, 268501. [4] Oganov et al. (2008) EPSL, 273, 38-47. [5] Boulard et al. (2011) PNAS, 108, 5184-5187.
One- and two-photon states for quantum information
NASA Astrophysics Data System (ADS)
Peters, Nicholas A.
To find expression stability among transgenic lines, the Recombinase Mediated Transgene Integration (RMTI) technology using the Cre/ lox-mediated site-specific gene integration system was used. The objectives were to develop an efficient method of site-specific transgene integration and to test the effectiveness of this method by assaying transgene expression in the RMTI lines. The RMTI technology allows the precise integration of a transgene in a previously placed target genomic location containing a lox site. The efficiency of CRE-mediated site-specific integration in rice by particle bombardment was found to vary from 3 to 28% in nine different experiments. Some hemizygous site-specific integration plants that were derived from homozygous target locus were found to undergo CRE-mediated reversion of the integration locus. No reversion was observed in callus; however, reverting cells may have been excluded due to selection pressure. The expression of the transgene gus was studied in all 40 callus lines, 12 regenerated T0 plants and the T1 and T2 progenies of 5 lines. The isogenic SC lines had an average expression level based on the activity of beta-glucuronidase of 158 +/- 9 units/mg protein (mean +/- SEM; n=3; variance within SC lines are expressed as standard error of the mean SEM) indicating a significantly higher level of expression, as compared to MC lines that had a much lower expression level 44 +/- 8 units/mg protein (mean +/- SEM; n=3) and the imprecise lines that had 22 +/- 8 units/mg protein (mean +/- SEM; n=3). Transgene expression in the callus cells of precise single copy lines varied by ˜3 fold, whereas that in multi-copy lines varied by ˜30 fold. Furthermore, precise single copy lines, on an average, contained ˜3.5 fold higher expression than multi-copy lines. Transgene expression in the plants of precise single-copy lines was highly variable, which was found to be due to the loss of the integration because of CRE-mediated reversion in the locus. (Abstract shortened by UMI.)
Smouldering Remediation (STAR) Technology: Field Pilot Tests and First Full Scale Application
NASA Astrophysics Data System (ADS)
Gerhard, J.; Kinsman, L.; Torero, J. L.
2015-12-01
STAR (Self-sustaining Treatment for Active Remediation) is an innovative remediation technology based on the principles of smoldering combustion where the contaminants are the fuel. The self-sustaining aspect means that a single, local ignition event can result in many days of contaminant destruction in situ. Presented research to date has focused on bench scale experiments, numerical modelling and process understanding. Presented here is the maturation of the in situ technology, including three field pilot tests and a full-scale implementation to treat coal tar-impacted soils. The first pilot determined a Radius of Influence (ROI) for a single ignition of approximately eight feet with an average propagation rate of the reaction of approximately one foot per day. TPH concentrations in soils were reduced from 10,000 milligrams per kilogram to a few hundred milligrams per kilogram. The second pilot was conducted in an area of significant void spaces created through the anthropogenic deposition of clay bricks and tiles. The void spaces led to pre-mature termination of the combustion reaction, limiting ROI and the effectiveness of the technology in this setting. The third case study involved the pilot testing, design, and full-scale implementation of STAR at a 37-acre former chemical manufacturing facility. Three phases of pilot testing were conducted within two hydrogeologic units at the site (i.e., surficial fill and deep alluvial sand units). Pilot testing within the fill demonstrated self-sustained coal tar destruction rates in excess of 800 kg/day supported through air injection at a single well. Deep sand unit testing (twenty-five feet below the water table) resulted in the treatment of a targeted six-foot layer of impacted fine sands to a radial distance of approximately twelve feet. These results (and additional parameters) were used to develop a full-scale STAR design consisting of approximately 1500 surficial fill ignition points and 500 deep sand ignition points and two treatment (air distribution and vapor collection / treatment) systems to remediate an approximately 14-acre footprint of contaminated soils within the project timelines (i.e., by mid-2016). Field activities began in 2014 and progress is currently on-schedule.
Paleointensity results for 0 and 3 ka from Hawaiian lava flows: a new approach to sampling
NASA Astrophysics Data System (ADS)
Cromwell, G.; Tauxe, L.; Staudigel, H.; Ron, H.; Trusdell, F.
2011-12-01
Paleointensity data are typically generated from core samples drilled out of the massive parts of lava flows. During Thellier-Thellier type experiments, these massive samples suffer from very low success rates (~20%), as shown by failure to meet statistical criteria. Low success generally occurs for two reasons: 1) alteration of the sample during the heating process, and 2) multi-domain behavior of massive material. Moreover, recent studies of historical lava flows show that massive samples may not accurately reflect the intensity of the magnetic field even when they are successful (Valet et al., 2010). Alternatively, submarine basaltic glasses (SBG) produce high success rates (~80%) for Thellier-Thellier type experiments, likely due to near instantaneous cooling rates which produce single-domain magnetic grains. In addition, SBG have been proven to produce accurate records of the magnetic field (e.g., Pick and Tauxe, 1993). In this study we investigate the success of paleointensity experiments on subaerial quenched basalts from Hawaii in the quest for single domain, rapidly cooled subaerial analogs to SBG. We also examine the effects of grain size and cooling rate on the accuracy of paleointensity results. During March 2011, we collected samples from 31 dated lava flows (0-3360 BP), including the [historical] 1950 C.E. and 2010 C.E. flows. Each lava flow was additionally subsampled when unique cooling structures within the unit could be identified. Results from the 1950 and 2010 glasses accurately record the expected geomagnetic field strength. We will present results of a comprehensive data set of Hawaiian paleointensity focused on about the last 3 ka.
12 CFR 541.25 - Single-family dwelling.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 12 Banks and Banking 5 2011-01-01 2011-01-01 false Single-family dwelling. 541.25 Section 541.25... AFFECTING FEDERAL SAVINGS ASSOCIATIONS § 541.25 Single-family dwelling. The term single-family dwelling means a structure designed for residential use by one family, or a unit so designed, whose owner owns...
12 CFR 541.25 - Single-family dwelling.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 12 Banks and Banking 5 2010-01-01 2010-01-01 false Single-family dwelling. 541.25 Section 541.25... AFFECTING FEDERAL SAVINGS ASSOCIATIONS § 541.25 Single-family dwelling. The term single-family dwelling means a structure designed for residential use by one family, or a unit so designed, whose owner owns...
Kelly, Patricia J; Berkel, LaVerne A; Nilsson, Johanna E
2014-01-01
Women are an integral part of Reserve and National Guard units and active duty armed forces of the United States. Deployment to conflict and war zones is a difficult experience for both soldiers and their families. On return from deployment, all soldiers face the challenge of reintegration into family life and society, but those from the National Guard and Reserve units face the additional challenge of reintegration in relative isolation from other soldiers. There is limited research about the reintegration experiences of women and the functioning of the families during reintegration following deployment. The goal was to document postdeployment family reintegration experiences of women in the National Guard. Semistructured interviews were conducted with 42 female members of Midwestern National Guard units. Directed content analysis was used to identify categories of experiences related to women's family reintegration. Five categories of postdeployment experience for female soldiers and their families were identified: Life Is More Complex, Loss of Military Role, Deployment Changes You, Reestablishing Partner Connections, and Being Mom Again. The categories reflected individual and family issues, and both need to be considered when soldiers and their families seek care. Additional research is needed to fully understand the specific impact of gender on women's reintegration.
Sayles, Mark; Winter, Ian Michael
2007-09-26
Spike trains were recorded from single units in the ventral cochlear nucleus of the anaesthetised guinea-pig in response to dynamic iterated rippled noise with positive and negative gain. The short-term running waveform autocorrelation functions of these stimuli show peaks at integer multiples of the time-varying delay when the gain is +1, and troughs at odd-integer multiples and peaks at even-integer multiples of the time-varying delay when the gain is -1. In contrast, the short-term autocorrelation of the Hilbert envelope shows peaks at integer multiples of the time-varying delay for both positive and negative gain stimuli. A running short-term all-order interspike interval analysis demonstrates the ability of single units to represent the modulated pitch contour in their short-term interval statistics. For units with low best frequency (approximate < or = 1.1 kHz) the temporal discharge pattern reflected the waveform fine structure regardless of unit classification (Primary-like, Chopper). For higher best frequency units the pattern of response varied according to unit type. Chopper units with best frequency approximate > or = 1.1 kHz responded to envelope modulation; showing no difference between their response to stimuli with positive and negative gain. Primary-like units with best frequencies in the range 1-3 kHz were still able to represent the difference in the temporal fine structure between dynamic rippled noise with positive and negative gain. No unit with a best frequency above 3 kHz showed a response to the temporal fine structure. Chopper units in this high frequency group showed significantly greater representation of envelope modulation relative to primary-like units with the same range of best frequencies. These results show that at the level of the cochlear nucleus there exists sufficient information in the time domain to represent the time-varying pitch associated with dynamic iterated rippled noise.
Learning Experiences in Technology: Integrated Teaching Unit Handbook: Book 1 for Grades K-2.
ERIC Educational Resources Information Center
Royal Oak City School District, MI.
The guide, part of Project LET (Learning Experiences in Technology), is intended to be used as a working copy and consists of 28 integrated teaching units for grade K-2 students. The duration of each teaching unit varies to allow for flexibility, individuality, creativity, and fulfillment of the needs and interests of each child. Each unit evolves…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Prior to 1978, the Wilsonville Advanced Coal Liquefaction facility material balance surrounded only the thermal liquefaction unit and involved analyses of only the slurry stream and individual gas streams. The distillate solvent yield was determined by difference. Subsequently, several modifications and additional process units were introduced to this single unit system. With the inclusion of the deashing unit in 1978 and the catalytic hydrogenation unit in 1981, the process has evolved into a sophisticated two-stage coal liquefaction process and has the potential for various modes of integration. This report presents an elemental balancing procedure and a simplified presentation format thatmore » is sufficiently flexible to meet current and future needs. The development of the elemental balancing technique and the relevant computer programs to handle the calculations have been addressed. This will be useful in modelling individual unit performance as well as determining the impact of each unit on the overall liquefaction system, provided the units are on a steady-state basis. Five different material balance envelopes are defined. Three of these envelopes pertain to the individual units (the thermal liquefaction or TL unit, the Critical Solvent Deashing or CSD unit and the H-Oil Ebullated Bed Hydrotreating or HTR unit). The fourth or single stage material balance envelope combines the TL and CSD units. The fifth envelope is the two-stage configuration combining all three units. 3 references.« less
Aetiology of obstructive azoospermia in Chinese infertility patients.
Han, H; Liu, S; Zhou, X-G; Tian, L; Zhang, X-D
2016-09-01
To explore the aetiology of obstructive azoospermia (OA) in Chinese infertility patients, 133 OA patients was included in this study diagnosed and evaluated by one major specialist trained urological infertility. We retrospected the medical records to collect relative information. All of the patients had been underwent physical examination, ultrasound scan to the urogenital system, serum hormone tests, genetic tests and two separate semen analyses. The mean age of all 133 patients was 32.7 ± 6.8 years. A total of 266 reproductive tract units (two/patient) were classified into four categories: no causes (Idiopathic) for 74 units (27.8%), single cause for 173 units (65.0%), double causes for 17 units (6.4%) and triple causes for two units (0.8%). As to single cause of OA, there were four types: trauma for 0 unit (0%), infection for 125 units (47.0%), dysplasia for 11 units (4.1%) and surgeries for 37 units (13.9%). As to total cause of OA, there were five types: infection for 144 units (54.1%), orchitis for 51 units (19.2%), epididymitis for 54 units (20.3%), gonorrhoea for 28 units (10.5%) and inguinal hernia repair surgery for 18 units (6.8%). The most frequent cause of obstructive azoospermia was infection revealed in these Chinese infertility populations, followed by idiopathic reason. © 2015 Blackwell Verlag GmbH.
Blur-resistant perimetric stimuli.
Horner, Douglas G; Dul, Mitchell W; Swanson, William H; Liu, Tiffany; Tran, Irene
2013-05-01
To develop perimetric stimuli that are resistant to the effects of peripheral defocus. One eye each was tested on subjects free of eye disease. Experiment 1 assessed spatial frequency, testing 12 subjects at eccentricities from 2 to 7 degrees using blur levels from 0 to 3 diopters (D) for two (Gabor) stimuli (spatial SD, 0.5 degrees; spatial frequencies, 0.5 and 1.0 cycles per degree [cpd]). Experiment 2 assessed stimulus size, testing 12 subjects at eccentricities from 4 to 7 degrees using blur levels 0 to 6 D for two Gaussians with SD of 0.5 and 0.25 degrees and a 0.5-cpd Gabor with SD of 0.5 degrees. Experiment 3 tested 13 subjects at eccentricities from fixation to 27 degrees using blur levels 0 to 6 D for Gabor stimuli at 56 locations; the spatial frequency ranged from 0.14 to 0.50 cpd with location, and SD was scaled accordingly. In experiment 1, blur by 3 D caused a small decline in log contrast sensitivity for the 0.5-cpd stimulus (mean ± SE, 0.09 ± 0.08 log units) and a larger (t = 7.7, p < 0.0001) decline for the 1.0-cpd stimulus (0.37 ± 0.13 log units). In experiment 2, blur by 6 D caused minimal decline for the larger Gaussian, by 0.17 ± 0.16 log units, and larger (t > 4.5, p < 0.001) declines for the smaller Gaussian (0.33 ± 0.16 log units) and the Gabor (0.36 ± 0.18 log units). In experiment 3, blur by 6 D caused declines by 0.27 ± 0.05 log units for eccentricities from 0 to 10 degrees, by 0.20 ± 0.04 log units for eccentricities from 10 to 20 degrees, and 0.13 ± 0.03 log units for eccentricities from 20 to 27 degrees. Experiments 1 and 2 allowed us to design stimuli for experiment 3 that were resistant to effects of peripheral defocus.
Hall, L Malcolm; Collins, Catherine; Collet, Bertrand
2018-02-02
The utility of molecular response data arising from in-vivo single and repeated measure fish disease-challenge experiments is compared. An in-silico 'experiment' involving the generation of two imaginary immune-molecule quantity response profiles over time for individual animals was carried out. Daily 'observed' molecule quantities were drawn from the 'known' individual response profiles to mimic the results of single and repeated measurement. The results indicate that repeated measure experiments are required to infer individual level response profiles, and that these experiments also provide more accurate summary statistics and data more suited to inferring the dependent ordering of the molecular response. Additionally repeated measure experiments utilise fewer animals than single measure experiments. These results are described alongside a discussion of experimental methodological issues pertinent to the adoption of aquatic animal repeated measure experimental designs. We conclude that investigators need to take particular care when making inferences from single measure experiments and that serious consideration should be given to using repeated measure experiments for in-vivo fish disease-challenge investigations. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.
Mehrabi, Arianeb; Mood, Zhoobin A; Fonouni, Hamidreza; Kashfi, Arash; Hillebrand, Norbert; Müller, Sascha A; Encke, Jens; Büchler, Markus W; Schmidt, Jan
2009-05-01
Over the past 4 decades, the surgical techniques of liver transplantation (LTx) have permanently evolved and been modified. Among these, the modified piggyback (MPB) technique by Belghiti offers specific advantages. The objective of this study was to present our single-center experience with the MPB technique in 500 cases. Recipients' perioperative data were prospectively collected and evaluated. Postoperative and specific complications, stay in the intensive and intermediate care unit, and the mortality rate with cause of death were analyzed. Most recipients were classified as Child C (49.1%). For the patients who underwent LTx for the first time, alcoholic (23.9%) and viral (22.2%) cirrhosis and hepatocellular carcinoma (15.1%) were the prevalent indications. The overall median warm ischemia time, anastomosis duration, and operative time were 45, 108, and 320 minutes, respectively. The median intraoperative blood loss was 1500 mL. A venovenous bypass was never needed to maintain hemodynamic stability. Only in a few cases was temporary inferior vena cava clamping necessary. Most prominent surgical complications were hemorrhage, hematoma, and wound dehiscence. Renal failure occurred in 6.2% of patients. The overall median stay in the intensive and intermediate care unit was 14 days. The mortality rates within 30 and 90 days were 6.3% and 13.3%, respectively. No technique-related death occurred. The MPB technique by Belghiti is a feasible and simple LTx technique. The caval flow is preserved during the anhepatic phase, and this minimizes the need for venovenous bypass or portocaval shunt. This technique requires only 1 caval anastomosis, which is easy to perform with a short anhepatic phase. To minimize the risk of outflow obstruction, attention should be paid by doing a wide cavocavostomy cranially to the donor inferior vena cava in a door-lock manner. This technique can be applied in almost all patients undergoing LTx for the first time and liver retransplantation as well.
CTS United States experiments. A progress report
NASA Technical Reports Server (NTRS)
Robbins, W. H.; Donoughe, P. L.
1976-01-01
The results are presented of the United States experiments activity to date. Wide segments of the population are involved in the Experiments Program including the scientific community, other government agencies, industry, and the education and health entities. The experiments are associated with both technological objectives and the demonstration of new community and social services via satellite.
The Effect of Single Pyramidal Neuron Firing Within Layer 2/3 and Layer 4 in Mouse V1.
Meyer, Jochen F; Golshani, Peyman; Smirnakis, Stelios M
2018-01-01
The influence of cortical cell spiking activity on nearby cells has been studied extensively in vitro . Less is known, however, about the impact of single cell firing on local cortical networks in vivo . In a pioneering study, Kwan and Dan (Kwan and Dan, 2012) reported that in mouse layer 2/3 (L2/3), under anesthesia , stimulating a single pyramidal cell recruits ~2.1% of neighboring units. Here we employ two-photon calcium imaging in layer 2/3 of mouse V1, in conjunction with single-cell patch clamp stimulation in layer 2/3 or layer 4, to probe, in both the awake and lightly anesthetized states , how (i) activating single L2/3 pyramidal neurons recruits neighboring units within L2/3 and from layer 4 (L4) to L2/3, and whether (ii) activating single pyramidal neurons changes population activity in local circuit. To do this, it was essential to develop an algorithm capable of quantifying how sensitive the calcium signal is at detecting effectively recruited units ("followers"). This algorithm allowed us to estimate the chance of detecting a follower as a function of the probability that an epoch of stimulation elicits one extra action potential (AP) in the follower cell. Using this approach, we found only a small fraction (<0.75%) of L2/3 cells to be significantly activated within a radius of ~200 μm from a stimulated neighboring L2/3 pyramidal cell. This fraction did not change significantly in the awake vs. the lightly anesthetized state, nor when stimulating L2/3 vs. underlying L4 pyramidal neurons. These numbers are in general agreement with, though lower than, the percentage of neighboring cells (2.1% pyramidal cells and interneurons combined) reported by Kwan and Dan to be activated upon stimulating single L2/3 pyramidal neurons under anesthesia (Kwan and Dan, 2012). Interestingly, despite the small number of individual units found to be reliably driven, we did observe a modest but significant elevation in aggregate population responses compared to sham stimulation. This underscores the distributed impact that single cell stimulation has on neighboring microcircuit responses, revealing only a small minority of relatively strongly connected partners. Patch-clamp stimulation in conjunction with 2-photon imaging shows that activating single layer-2/3 or layer-4 pyramidal neurons produces few (<1% of local units) reliable single-cell followers in L2/3 of mouse area V1, either under light anesthesia or in quiet wakefulness: instead, single cell stimulation was found to elevate aggregate population activity in a weak but highly distributed fashion.
Interactive Screen Experiments with Single Photons
ERIC Educational Resources Information Center
Bronner, Patrick; Strunz, Andreas; Silberhorn, Christine; Meyn, Jan-Peter
2009-01-01
Single photons are used for fundamental quantum physics experiments as well as for applications. Originally being a topic of advance courses, such experiments are increasingly a subject of undergraduate courses. We provide interactive screen experiments (ISE) for supporting the work in a real laboratory, and for students who do not have access to…
Rodriguez-Lorenzo, Andres; Audolfsson, Thorir; Wong, Corrine; Cheng, Angela; Arbique, Gary; Nowinski, Daniel; Rozen, Shai
2015-10-01
The aim of this study was to evaluate the contribution of a single unilateral facial vein in the venous outflow of total-face allograft using three-dimensional computed tomographic imaging techniques to further elucidate the mechanisms of venous complications following total-face transplant. Full-face soft-tissue flaps were harvested from fresh adult human cadavers. A single facial vein was identified and injected distally to the submandibular gland with a radiopaque contrast (barium sulfate/gelatin mixture) in every specimen. Following vascular injections, three-dimensional computed tomographic venographies of the faces were performed. Images were viewed using TeraRecon Software (Teracon, Inc., San Mateo, CA, USA) allowing analysis of the venous anatomy and perfusion in different facial subunits by observing radiopaque filling venous patterns. Three-dimensional computed tomographic venographies demonstrated a venous network with different degrees of perfusion in subunits of the face in relation to the facial vein injection side: 100% of ipsilateral and contralateral forehead units, 100% of ipsilateral and 75% of contralateral periorbital units, 100% of ipsilateral and 25% of contralateral cheek units, 100% of ipsilateral and 75% of contralateral nose units, 100% of ipsilateral and 75% of contralateral upper lip units, 100% of ipsilateral and 25% of contralateral lower lip units, and 50% of ipsilateral and 25% of contralateral chin units. Venographies of the full-face grafts revealed better perfusion in the ipsilateral hemifaces from the facial vein in comparison with the contralateral hemifaces. Reduced perfusion was observed mostly in the contralateral cheek unit and contralateral lower face including the lower lip and chin units. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Butler, T J; Kilbreath, S L; Gorman, R B; Gandevia, S C
2005-08-15
Flexor digitorum superficialis (FDS) is an extrinsic multi-tendoned muscle which flexes the proximal interphalangeal joints of the four fingers. It comprises four digital components, each with a tendon that inserts onto its corresponding finger. To determine the degree to which these digital components can be selectively recruited by volition, we recorded the activity of a single motor unit in one component via an intramuscular electrode while the subject isometrically flexed each of the remaining fingers, one at a time. The finger on which the unit principally acted was defined as the 'test finger' and that which flexed isometrically was the 'active' finger. Activity in 79 units was recorded. Isometric finger flexion forces of 50% maximum voluntary contraction (MVC) activated less than 50% of single units in components of FDS acting on fingers that were not voluntarily flexed. With two exceptions, the median recruitment threshold for all active-test finger combinations involving the index, middle, ring and little finger test units was between 49 and 60% MVC (60% MVC being the value assigned to those not recruited). The exceptions were flexion of the little finger while recording from ring finger units (median: 40% MVC), and vice versa (median: 2% MVC). For all active-test finger combinations, only 35/181 units were activated when the active finger flexed at less than 20% MVC, and the fingers were adjacent for 28 of these. Functionally, to recruit FDS units during grasping and lifting, relatively heavy objects were required, although systematic variation occurred with the width of the object. In conclusion, FDS components can be selectively activated by volition and this may be especially important for grasping at high forces with one or more fingers.
Harada, Ken; Akashi, Tetsuya; Niitsu, Kodai; Shimada, Keiko; Ono, Yoshimasa A; Shindo, Daisuke; Shinada, Hiroyuki; Mori, Shigeo
2018-01-17
Advanced electron microscopy technologies have made it possible to perform precise double-slit interference experiments. We used a 1.2-MV field emission electron microscope providing coherent electron waves and a direct detection camera system enabling single-electron detections at a sub-second exposure time. We developed a method to perform the interference experiment by using an asymmetric double-slit fabricated by a focused ion beam instrument and by operating the microscope under a "pre-Fraunhofer" condition, different from the Fraunhofer condition of conventional double-slit experiments. Here, pre-Fraunhofer condition means that each single-slit observation was performed under the Fraunhofer condition, while the double-slit observations were performed under the Fresnel condition. The interference experiments with each single slit and with the asymmetric double slit were carried out under two different electron dose conditions: high-dose for calculation of electron probability distribution and low-dose for each single electron distribution. Finally, we exemplified the distribution of single electrons by color-coding according to the above three types of experiments as a composite image.
Transperitoneal laparoscopic adrenalectomy. Our experience.
Antonino, Antonio; Rosato, Andrea; Zenone, Pasquale; Ranieri, Raffaele; Maglio, Mauro; Lupone, Gennaro; Gragnano, Eugenio; Sangiuliano, Nicola; Docimo, Giovanni; De Palma, Maurizio
2013-01-01
Laparoscopic adrenalectomy is considered the standard technique for the surgical removal of the adrenal gland. This report is about a 4-year single experience in our Endocrine and General Surgery Unit with laparoscopic adrenalectomy. A total of 24 lateral transperitoneal laparoscopic adrenalectomies were performed. The indications for laparoscopic surgery were: aldosteronoma in 3 patients, pheochromocytoma in 6 patients, nonfunctioning adenoma in 6 patients, adenoma causing Cushing's syndrome in 3 patients, 1 lymphangioma-like adenomatoid tumor, 1 myelolipoma, 1 complicated adrenal cyst, 2 adrenocortical carcinomas, 1 lung metastasis. All except two had successful laparoscopic adrenalectomy. Complication occurred in one patient. 3 patients underwent other associated laparoscopic procedures. Operative time ranged from 100 to 240 minutes for laparoscopic adrenalectomy, from 180 to 210 minutes in the cases with two associated laparoscopic procedures, 5 hours for bilateral adrenalectomy; the postoperative hospital stay for laparoscopic adrenalectomy ranged from 4 to 8 days (6,79 days) and from 7 to 13 days (9,12 days) for patients undergoing the open or converted procedure. Laparoscopic adrenalectomy is technically feasible and reproducible. We evaluate the effectiveness of laparoscopic adrenalectomy for a variety of endocrine disorders except in the case of invasive carcinoma or large masses. Antonio Cardarelli Endocrine and General Surgery Unit in Naples is known as a specialized center for thyroid and parathyroid surgery; in future, we could also become a high-volume laparoscopic referral center for adrenal gland pathologies.
Ng, George W Y; Leung, Anne K H; Sin, K C; Au, S Y; Chan, Stanley C H; Chan, Osburga P K; Wu, Helen H L
2014-10-01
To present the 3-year experience of using venovenous extracorporeal membrane oxygenation for patients with severe respiratory failure in a single centre in Hong Kong. Case series. A 19-bed Intensive Care Unit of a tertiary hospital in Hong Kong. All patients who were managed with venovenous extracorporeal membrane oxygenation from 1 July 2010 to 30 June 2013 in the Intensive Care Unit. Overall, 31 patients (mean age, 42.2 years, standard deviation, 14.1 years; 21 males) received venovenous extracorporeal membrane oxygenation for the treatment of severe respiratory failure. Of these, 90.3% (28 patients) presented with pneumonia as the cause of the respiratory failure, and 22 of them had identifiable causes. A total of nine (29.0%) patients were diagnosed to have H1N1 infection. The median Murray score was 3.5 (interquartile range, 3.0-3.5); the median duration of venovenous extracorporeal membrane oxygenation support was 5.0 (2.8-8.6) days; and the median duration of mechanical ventilator support was 18.2 (7.8-27.9) days. The overall intensive care unit mortality was 19.4% (n=6). The overall in-hospital mortality and the 28-day mortality were both 22.6% (n=7). Among the 22 patients who had identifiable infective causes, those suffering from viral infection had lower intensive care unit and hospital mortality than those who had bacterial infection (8.3% vs 20.0%). All the H1N1 patients survived. Complications related to extracorporeal membrane oxygenation included severe bleeding (n=2; 6.5%) and mechanical complications of the circuits (n=3; 9.7%). Venovenous extracorporeal membrane oxygenation is an effective adjunctive therapy and can be used as a life-saving procedure for carefully selected patients with severe acute respiratory distress syndrome when the limits of standard therapy have been reached.
NASA Astrophysics Data System (ADS)
Lamkin, T.; Whitney, Brian
1995-09-01
This paper describes the engineering thought process behind the failure analysis, redesign, and rework of the flight hardware for the Brilliant Eyes Thermal Storage Unit (BETSU) experiment. This experiment was designed to study the zero-g performance of 2-methylpentane as a suitable phase change material. This hydrocarbon served as the cryogenic storage medium for the BETSU experiment which was flown 04 Mar 94 on board Shuttle STS-62. Ground testing had indicated satisfactory performance of the BETSU at the 120 Kelvin design temperature. However, questions remained as to the micro-gravity performance of this unit; potential deviations in ground (1 g) versus space flight (0 g) performance, and how the unit would operate in a realistic space environment undergoing cyclical operation. The preparations and rework performed on the BETSU unit, which failed initial flight qualification, give insight and lessons learned to successfully develop and qualify a space flight experiment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alfonso Hernandez, Laura; Nelson, Tammie Renee; Gelin, Maxim F.
The interchromophoric energy-transfer pathways between weakly coupled units in a π-conjugated phenylene–ethynylene macrocycle and its half-ring analogue have been investigated using the nonadiabatic excited-state molecular dynamics approach. To track the flow of electronic transition density between macrocycle units, we formulate a transition density flux analysis adapted from the statistical minimum flow method previously developed to investigate vibrational energy flow. Following photoexcitation, transition density is primarily delocalized on two chromophore units and the system undergoes ultrafast energy transfer, creating a localized excited state on a single unit. In the macrocycle, distinct chromophore units donate transition density to a single acceptor unitmore » but do not interchange transition density among each other. We find that energy transfer in the macrocycle is slower than in the corresponding half ring because of the presence of multiple interfering energy-transfer pathways. Finally, simulation results are validated by modeling the fluorescence anisotropy decay.« less
Interference of interchromophoric energy-transfer pathways in π-conjugated macrocycles
Alfonso Hernandez, Laura; Nelson, Tammie Renee; Gelin, Maxim F.; ...
2016-11-10
The interchromophoric energy-transfer pathways between weakly coupled units in a π-conjugated phenylene–ethynylene macrocycle and its half-ring analogue have been investigated using the nonadiabatic excited-state molecular dynamics approach. To track the flow of electronic transition density between macrocycle units, we formulate a transition density flux analysis adapted from the statistical minimum flow method previously developed to investigate vibrational energy flow. Following photoexcitation, transition density is primarily delocalized on two chromophore units and the system undergoes ultrafast energy transfer, creating a localized excited state on a single unit. In the macrocycle, distinct chromophore units donate transition density to a single acceptor unitmore » but do not interchange transition density among each other. We find that energy transfer in the macrocycle is slower than in the corresponding half ring because of the presence of multiple interfering energy-transfer pathways. Finally, simulation results are validated by modeling the fluorescence anisotropy decay.« less
24 CFR 983.56 - Cap on number of PBV units in each building.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 24 Housing and Urban Development 4 2011-04-01 2011-04-01 false Cap on number of PBV units in each... URBAN DEVELOPMENT PROJECT-BASED VOUCHER (PBV) PROGRAM Selection of PBV Owner Proposals § 983.56 Cap on... single-family building; (ii) Excepted units in a multifamily building. (2) Terms (i) “Excepted units...
Support for non-locking parallel reception of packets belonging to a single memory reception FIFO
Chen, Dong [Yorktown Heights, NY; Heidelberger, Philip [Yorktown Heights, NY; Salapura, Valentina [Yorktown Heights, NY; Senger, Robert M [Yorktown Heights, NY; Steinmacher-Burow, Burkhard [Boeblingen, DE; Sugawara, Yutaka [Yorktown Heights, NY
2011-01-27
A method and apparatus for distributed parallel messaging in a parallel computing system. A plurality of DMA engine units are configured in a multiprocessor system to operate in parallel, one DMA engine unit for transferring a current packet received at a network reception queue to a memory location in a memory FIFO (rmFIFO) region of a memory. A control unit implements logic to determine whether any prior received packet destined for that rmFIFO is still in a process of being stored in the associated memory by another DMA engine unit of the plurality, and prevent the one DMA engine unit from indicating completion of storing the current received packet in the reception memory FIFO (rmFIFO) until all prior received packets destined for that rmFIFO are completely stored by the other DMA engine units. Thus, there is provided non-locking support so that multiple packets destined for a single rmFIFO are transferred and stored in parallel to predetermined locations in a memory.
Electrostatic Microactuators for Precise Positioning of Neural Microelectrodes
Muthuswamy, Jit; Okandan, Murat; Jain, Tilak; Gilletti, Aaron
2006-01-01
Microelectrode arrays used for monitoring single and multineuronal action potentials often fail to record from the same population of neurons over a period of time likely due to micromotion of neurons away from the microelectrode, gliosis around the recording site and also brain movement due to behavior. We report here novel electrostatic microactuated microelectrodes that will enable precise repositioning of the microelectrodes within the brain tissue. Electrostatic comb-drive microactuators and associated microelectrodes are fabricated using the SUMMiT V™ (Sandia's Ultraplanar Multilevel MEMS Technology) process, a five-layer polysilicon micromachining technology of the Sandia National labs, NM. The microfabricated microactuators enable precise bidirectional positioning of the microelectrodes in the brain with accuracy in the order of 1 μm. The microactuators allow for a linear translation of the microelectrodes of up to 5 mm in either direction making it suitable for positioning microelectrodes in deep structures of a rodent brain. The overall translation was reduced to approximately 2 mm after insulation of the microelectrodes with epoxy for monitoring multiunit activity. The microactuators are capable of driving the microelectrodes in the brain tissue with forces in the order of several micro-Newtons. Single unit recordings were obtained from the somatosensory cortex of adult rats in acute experiments demonstrating the feasibility of this technology. Further optimization of the insulation, packaging and interconnect issues will be necessary before this technology can be validated in long-term experiments. PMID:16235660
Safety and efficacy of percutaneous nephrolithotomy for the treatment of paediatric urolithiasis
Veeratterapillay, R; Shaw, MBK; Williams, R; Haslam, P; Lall, A; De la Hunt, M; Hasan, ST; Thomas, DJ
2012-01-01
INTRODUCTION Paediatric percutaneous nephrolithotomy (PCNL) has revolutionised the treatment of paediatric nephrolithiasis. Paediatric PCNL has been performed using both adult and paediatric instruments. Stone clearance rates and complications vary according to the technique used and surgeon experience. We present our experience with PCNL using adult instruments and a 28Fr access tract for large renal calculi in children under 18 years. METHODS All patients undergoing PCNL at our institution between 2000 and 2009 were reviewed. Demographics, surgical details and post-operative follow-up information were obtained to identify stone clearance rates and complications. RESULTS PCNL was performed in 32 renal units in 31 patients (mean age: 10.8 years). The mean stone diameter was 19mm (range: 5–40mm). Twenty-six cases required single puncture and six required multiple tracts. Overall, 11 staghorn stones, 10 multiple calyceal stones and 11 single stones were treated. Twenty-seven patients (84%) were completely stone free following initial PCNL. Two cases had extracorporeal shock wave lithotripsy for residual fragments, giving an overall stone free rate of 91% following treatment. There was no significant bleeding or sepsis encountered either during the operation or in the post-operative setting. No patient required or received a blood transfusion. CONCLUSIONS Paediatric PCNL can be performed safely with minimal morbidity using adult instruments for large stone burden, enabling rapid and complete stone clearance. PMID:23131231
Safety and efficacy of percutaneous nephrolithotomy for the treatment of paediatric urolithiasis.
Veeratterapillay, R; Shaw, M B K; Williams, R; Haslam, P; Lall, A; De la Hunt, M; Hasan, S T; Thomas, D J
2012-11-01
Paediatric percutaneous nephrolithotomy (PCNL) has revolutionised the treatment of paediatric nephrolithiasis. Paediatric PCNL has been performed using both adult and paediatric instruments. Stone clearance rates and complications vary according to the technique used and surgeon experience. We present our experience with PCNL using adult instruments and a 28Fr access tract for large renal calculi in children under 18 years. All patients undergoing PCNL at our institution between 2000 and 2009 were reviewed. Demographics, surgical details and post-operative follow-up information were obtained to identify stone clearance rates and complications. PCNL was performed in 32 renal units in 31 patients (mean age: 10.8 years). The mean stone diameter was 19mm (range: 5-40mm). Twenty-six cases required single puncture and six required multiple tracts. Overall, 11 staghorn stones, 10 multiple calyceal stones and 11 single stones were treated. Twenty-seven patients (84%) were completely stone free following initial PCNL. Two cases had extracorporeal shock wave lithotripsy for residual fragments, giving an overall stone free rate of 91% following treatment. There was no significant bleeding or sepsis encountered either during the operation or in the post-operative setting. No patient required or received a blood transfusion. Paediatric PCNL can be performed safely with minimal morbidity using adult instruments for large stone burden, enabling rapid and complete stone clearance.
Mother-to-infant emotional involvement at birth.
Figueiredo, Bárbara; Costa, Raquel; Pacheco, Alexandra; Pais, Alvaro
2009-07-01
To study mother-to-infant emotional involvement at birth, namely factors (socio-demographics, previous life events, type of delivery, pain at childbirth, support from partner, infant characteristics, early experiences with the newborn, and mother's mood) that interfere with the mother's positive, negative and not clear emotions toward the newborn. The Bonding Scale (an extended Portuguese version of the 'New Mother-to-Infant Bonding Scale') and the Edinburgh Postnatal Depression Scale were administrated during the first after delivery days to 315 mothers recruited at Júlio Dinis Maternity Hospital (MJD, Porto, Portugal). A worse emotional involvement with the newborn was observed when the mother was unemployed, unmarried, had less than grade 9, previous obstetrical/psychological problems or was depressed, as well as when the infant was female, had neonatal problems or was admitted in the intensive care unit. Lower total bonding results were significantly predicted when the mother was depressed and had a lower educational level; being depressed, unemployed and single predicted more negative emotions toward the infant as well. No significant differences in the mother-to-infant emotional involvement were obtained for events related to childbirth, such as type of delivery, pain and partner support, or early experiences with the newborn; these events do not predict mother's bonding results either. The study results support the need for screening and supporting depressed, unemployed and single mothers, in order to prevent bonding difficulties with the newborn at birth.
Passive dendrites enable single neurons to compute linearly non-separable functions.
Cazé, Romain Daniel; Humphries, Mark; Gutkin, Boris
2013-01-01
Local supra-linear summation of excitatory inputs occurring in pyramidal cell dendrites, the so-called dendritic spikes, results in independent spiking dendritic sub-units, which turn pyramidal neurons into two-layer neural networks capable of computing linearly non-separable functions, such as the exclusive OR. Other neuron classes, such as interneurons, may possess only a few independent dendritic sub-units, or only passive dendrites where input summation is purely sub-linear, and where dendritic sub-units are only saturating. To determine if such neurons can also compute linearly non-separable functions, we enumerate, for a given parameter range, the Boolean functions implementable by a binary neuron model with a linear sub-unit and either a single spiking or a saturating dendritic sub-unit. We then analytically generalize these numerical results to an arbitrary number of non-linear sub-units. First, we show that a single non-linear dendritic sub-unit, in addition to the somatic non-linearity, is sufficient to compute linearly non-separable functions. Second, we analytically prove that, with a sufficient number of saturating dendritic sub-units, a neuron can compute all functions computable with purely excitatory inputs. Third, we show that these linearly non-separable functions can be implemented with at least two strategies: one where a dendritic sub-unit is sufficient to trigger a somatic spike; another where somatic spiking requires the cooperation of multiple dendritic sub-units. We formally prove that implementing the latter architecture is possible with both types of dendritic sub-units whereas the former is only possible with spiking dendrites. Finally, we show how linearly non-separable functions can be computed by a generic two-compartment biophysical model and a realistic neuron model of the cerebellar stellate cell interneuron. Taken together our results demonstrate that passive dendrites are sufficient to enable neurons to compute linearly non-separable functions.
Passive Dendrites Enable Single Neurons to Compute Linearly Non-separable Functions
Cazé, Romain Daniel; Humphries, Mark; Gutkin, Boris
2013-01-01
Local supra-linear summation of excitatory inputs occurring in pyramidal cell dendrites, the so-called dendritic spikes, results in independent spiking dendritic sub-units, which turn pyramidal neurons into two-layer neural networks capable of computing linearly non-separable functions, such as the exclusive OR. Other neuron classes, such as interneurons, may possess only a few independent dendritic sub-units, or only passive dendrites where input summation is purely sub-linear, and where dendritic sub-units are only saturating. To determine if such neurons can also compute linearly non-separable functions, we enumerate, for a given parameter range, the Boolean functions implementable by a binary neuron model with a linear sub-unit and either a single spiking or a saturating dendritic sub-unit. We then analytically generalize these numerical results to an arbitrary number of non-linear sub-units. First, we show that a single non-linear dendritic sub-unit, in addition to the somatic non-linearity, is sufficient to compute linearly non-separable functions. Second, we analytically prove that, with a sufficient number of saturating dendritic sub-units, a neuron can compute all functions computable with purely excitatory inputs. Third, we show that these linearly non-separable functions can be implemented with at least two strategies: one where a dendritic sub-unit is sufficient to trigger a somatic spike; another where somatic spiking requires the cooperation of multiple dendritic sub-units. We formally prove that implementing the latter architecture is possible with both types of dendritic sub-units whereas the former is only possible with spiking dendrites. Finally, we show how linearly non-separable functions can be computed by a generic two-compartment biophysical model and a realistic neuron model of the cerebellar stellate cell interneuron. Taken together our results demonstrate that passive dendrites are sufficient to enable neurons to compute linearly non-separable functions. PMID:23468600
Education or Entertainment: The Television Portrayal of Single Parents in the '90s.
ERIC Educational Resources Information Center
Holecek, Peggy
As the number of single-parent families has grown in the United States, network television programming has increasingly included programs portraying single parents and their attempts to cope with the role. In a study, the "Fall Preview" edition of "TV Guide" magazine was used to select programs featuring single mothers or…
Plastic Organic Scintillator Chemistry
NASA Astrophysics Data System (ADS)
Brightwell, C. R.; Temanson, E. S.; Febbraro, M. T.
2017-09-01
Due to their high light output, quick decay time, affordability, durability and ability to be molded, plastic organic scintillators are increasingly becoming a more viable method of particle detection. Since the plastic is composed entirely of single molecular chains with repeating units, scintillating properties remain stable despite changes in experimental conditions. Different scintillating plastics can be modified and tailored to suit specific experiments depending on a variety of requirements such as light output, scintillating wavelength, and PMT compatibility. The synthesis chemistry of a recent but well-known scintillating polyester, polyethylene naphthalate (PEN) will be presented to demonstrate how plastic organic scintillators can be modified for different particle detection experiments. PEN has been successfully synthesized at ORNL, and procedures are currently being investigated to modify PEN using different reactants and catalysts. The goal is to achieve a transparent scintillating plastic with an incorporated wavelength shifter in the chain that scintillates with a wavelength around 440 nm. The status of this project will be presented. This research is supported by the U. S. Department of Energy Office of Science.
Parallel ptychographic reconstruction
Nashed, Youssef S. G.; Vine, David J.; Peterka, Tom; ...
2014-12-19
Ptychography is an imaging method whereby a coherent beam is scanned across an object, and an image is obtained by iterative phasing of the set of diffraction patterns. It is able to be used to image extended objects at a resolution limited by scattering strength of the object and detector geometry, rather than at an optics-imposed limit. As technical advances allow larger fields to be imaged, computational challenges arise for reconstructing the correspondingly larger data volumes, yet at the same time there is also a need to deliver reconstructed images immediately so that one can evaluate the next steps tomore » take in an experiment. Here we present a parallel method for real-time ptychographic phase retrieval. It uses a hybrid parallel strategy to divide the computation between multiple graphics processing units (GPUs) and then employs novel techniques to merge sub-datasets into a single complex phase and amplitude image. Results are shown on a simulated specimen and a real dataset from an X-ray experiment conducted at a synchrotron light source.« less
Learning shapes the aversion and reward responses of lateral habenula neurons
Wang, Daqing; Li, Yi; Feng, Qiru; Guo, Qingchun; Zhou, Jingfeng; Luo, Minmin
2017-01-01
The lateral habenula (LHb) is believed to encode negative motivational values. It remains unknown how LHb neurons respond to various stressors and how learning shapes their responses. Here, we used fiber-photometry and electrophysiology to track LHb neuronal activity in freely-behaving mice. Bitterness, pain, and social attack by aggressors intensively excite LHb neurons. Aversive Pavlovian conditioning induced activation by the aversion-predicting cue in a few trials. The experience of social defeat also conditioned excitatory responses to previously neutral social stimuli. In contrast, fiber photometry and single-unit recordings revealed that sucrose reward inhibited LHb neurons and often produced excitatory rebound. It required prolonged conditioning and high reward probability to induce inhibition by reward-predicting cues. Therefore, LHb neurons can bidirectionally process a diverse array of aversive and reward signals. Importantly, their responses are dynamically shaped by learning, suggesting that the LHb participates in experience-dependent selection of behavioral responses to stressors and rewards. DOI: http://dx.doi.org/10.7554/eLife.23045.001 PMID:28561735
One-Shot Learning of Human Activity With an MAP Adapted GMM and Simplex-HMM.
Rodriguez, Mario; Orrite, Carlos; Medrano, Carlos; Makris, Dimitrios
2016-05-10
This paper presents a novel activity class representation using a single sequence for training. The contribution of this representation lays on the ability to train an one-shot learning recognition system, useful in new scenarios where capturing and labeling sequences is expensive or impractical. The method uses a universal background model of local descriptors obtained from source databases available on-line and adapts it to a new sequence in the target scenario through a maximum a posteriori adaptation. Each activity sample is encoded in a sequence of normalized bag of features and modeled by a new hidden Markov model formulation, where the expectation-maximization algorithm for training is modified to deal with observations consisting in vectors in a unit simplex. Extensive experiments in recognition have been performed using one-shot learning over the public datasets Weizmann, KTH, and IXMAS. These experiments demonstrate the discriminative properties of the representation and the validity of application in recognition systems, achieving state-of-the-art results.
Personal experience with the procurement of 132 liver allografts
Yanaga, K.; Tzakis, A.G.; Starzl, T.E.
2010-01-01
A single donor surgeon's experience procuring the livers from 132 donors is described. Thirty-seven grafts (28.9%) had hepatic arterial anomalies, 19 (14.4%) of which required arterial reconstruction prior to transplantation. Of the 121 grafts evaluated for early function, 103 grafts (85.2%) functioned well, whereas 14 grafts (11.6%) functioned poorly and 4 grafts (3.3%) failed to function at all. The variables associated with less than optimal function of the graft consisted of donor age (P < 0.05), duration of donor's stay in the intensive care unit (P < 0.005), abnormal graft appearance (P < 0.05), and such recipient problems as vascular thromboses during or immediately following transplantation (P < 0.005). A new preservation fluid, University of Wisconsin solution, allowed safe and longer cold storage of the liver allograft than did Euro-Collins' solution (P < 0.0001). A parameter of liver allograft viability, which is simple and predictive of allograft function prior to the actual transplant procedure, is urgently needed. PMID:2803485
Peer-supported storytelling for grieving pediatric oncology nurses.
Macpherson, Catherine Fiona
2008-01-01
Telling stories about deceased patients to supportive peers is frequently mentioned as an activity used for meaning-making in anecdotal reports of clinical practice and the literature addressing nurses' experiences caring for dying children. This study examines peer-supported storytelling for grieving pediatric oncology nurses using a mixed methods single-group descriptive repeated measures design. Participants were 6 registered nurses from a tertiary care pediatric hospital inpatient oncology unit who self-identified as experiencing grief. Participants met in self-selected dyads for 2 storytelling sessions. Questionnaires were completed at baseline, midpoint, and study end. Sessions were audio-recorded. Participants reported (1) receiving and providing support during sessions; (2) that sessions had an impact on their grief; (3) that sessions had an impact on their meaning-making, and the explicit session focus on making sense of and identifying benefit in their experiences was particularly helpful. There was a significant positive correlation between participant report of number of special patient deaths during career and impact of sessions on grief.
NASA Astrophysics Data System (ADS)
Lorenz, John C.; Warpinski, Norman R.; Teufel, Lawrence W.; Branagan, Paul T.; Sattler, Allan R.; Northrop, David A.
Hundreds of millions of cubic meters of natural gas are locked up in low-permeability, natural gas reservoirs. The Multiwell Experiment (MWX) was designed to characterize such reservoirs, typical of much of the western United States, and to assess and develop a technology for the production of this unconventional resource. Flow-rate tests of the MWX reservoirs indicate a system permeability that is several orders of magnitude higher than laboratory permeability measurements made on matrix-rock sandstones. This enhanced permeability is caused by natural fractures. The single set of fractures present in the reservoirs provides a significant permeability anisotropy that is aligned with the maximum in situ horizontal stress. Hydraulic fractures therefore form parallel to the natural fractures and are consequently an inefficient mechanism for stimulation. Successful stimulation may be possible by perturbing the local stress field with a large hydraulic fracture in one well so that a second hydraulic fracture in an offset well propagates transverse to the natural fracture permeability trend.
Correlates of a single cortical action potential in the epidural EEG
Teleńczuk, Bartosz; Baker, Stuart N; Kempter, Richard; Curio, Gabriel
2015-01-01
To identify the correlates of a single cortical action potential in surface EEG, we recorded simultaneously epidural EEG and single-unit activity in the primary somatosensory cortex of awake macaque monkeys. By averaging over EEG segments coincident with more than hundred thousand single spikes, we found short-lived (≈ 0.5 ms) triphasic EEG deflections dominated by high-frequency components > 800 Hz. The peak-to-peak amplitude of the grand-averaged spike correlate was 80 nV, which matched theoretical predictions, while single-neuron amplitudes ranged from 12 to 966 nV. Combining these estimates with post-stimulus-time histograms of single-unit responses to median-nerve stimulation allowed us to predict the shape of the evoked epidural EEG response and to estimate the number of contributing neurons. These findings establish spiking activity of cortical neurons as a primary building block of high-frequency epidural EEG, which thus can serve as a quantitative macroscopic marker of neuronal spikes. PMID:25554430
A Unit Cell Laboratory Experiment: Marbles, Magnets, and Stacking Arrangements
ERIC Educational Resources Information Center
Collins, David C.
2011-01-01
An undergraduate first-semester general chemistry laboratory experiment introducing face-centered, body-centered, and simple cubic unit cells is presented. Emphasis is placed on the stacking arrangement of solid spheres used to produce a particular unit cell. Marbles and spherical magnets are employed to prepare each stacking arrangement. Packing…
Child Guidance for Child Caregivers: Student Laboratory Manual.
ERIC Educational Resources Information Center
Texas Tech Univ., Lubbock. Home Economics Curriculum Center.
Designed to enhance student knowledge of and skills in child guidance in group care settings, this manual provides 50 laboratory experiences for five units. Units cover foundations and assumptions (2 laboratory experiences), developmental factors (8), indirect guidance (14), direct guidance (14), and strategies (12). Each unit includes performance…
Subsyllabic Unit Preference in Young Chinese Children
ERIC Educational Resources Information Center
Wang, Min; Cheng, Chenxi
2008-01-01
We reported three experiments investigating subsyllabic unit preference in young Chinese children. In Experiment 1, a Chinese sound similarity judgment task was designed in which 48 pair of stimuli varied in terms of shared subsyllabic units (i.e., vowel, body, rime, onset-coda). Grade 1 Chinese-speaking monolingual children judged pairs with…
Mountain Plains Learning Experience Guide: Marketing. Course: Visual Merchandising.
ERIC Educational Resources Information Center
Preston, T.; Egan, B.
One of thirteen individualized courses included in a marketing curriculum, this course covers the steps to be followed in planning, constructing, and evaluating the effectiveness of merchandise displays. The course is comprised of one unit, General Merchandise Displays. The unit begins with a Unit Learning Experience Guide that gives directions…
Electric power distribution and load transfer system
NASA Technical Reports Server (NTRS)
Bradford, Michael P. (Inventor); Parkinson, Gerald W. (Inventor); Grant, Ross M. (Inventor)
1987-01-01
A power distribution system includes a plurality of power sources and load transfer units including transistors and diodes connected in series and leading to a common power output, each of the transistors being controller switchable subject to voltage levels of the respective input and output sides of said transistors, and the voltage and current level of said common power output. The system is part of an interconnection scheme in which all but one of the power sources is connected to a single load transfer unit, enabling the survival of at least a single power source with the failure of one of the load transfer units.
Electric power distribution and load transfer system
NASA Technical Reports Server (NTRS)
Bradford, Michael P. (Inventor); Parkinson, Gerald W. (Inventor); Grant, Ross M. (Inventor)
1989-01-01
A power distribution system includes a plurality of power sources and load transfer units including transistors and diodes connected in series and leading to a common power output, each of the transistors being controller switchable subject to voltage levels of the respective input and output sides of said transistors, and the voltage and current level of said common power output. The system is part of an interconnection scheme in which all but one of the power sources is connected to a single load transfer unit, enabling the survival of at least a single power source with the failure of one of the load transfer units.
NASA Technical Reports Server (NTRS)
Swickrath, Michael J.; Watts, Carly; Anderson, Molly; McMillin, Summer; Broerman, Craig; Colunga, Aaron; Vogel, Matthew
2012-01-01
Controlling carbon dioxide (CO2) and water (H2O) vapor concentrations in a space suit is critical to ensuring an astronauts safety, comfort, and capability to perform extra-vehicular activity (EVA) tasks. Historically, this has been accomplished using lithium hydroxide (LiOH) and metal oxide (MetOx) canisters. Lithium hydroxide is a consumable material that requires priming with water before it becomes effective at removing carbon dioxide. MetOx is regenerable through a power-intensive thermal cycle but is significantly heavier on a volume basis than LiOH. As an alternative, amine-based vacuum swing beds are under aggressive development for EVA applications. The vacuum swing units control atmospheric concentrations of both CO2 and H2O through fully-regenerative process. The current concept, referred to as the rapid cycle amine (RCA), has resulted in numerous laboratory prototypes. Performance of these prototypes have been assessed experimentally and documented in previous reports. To support developmental e orts, a first principles model has also been established for the vacuum swing sorption technology. For the first time in several decades, a major re-design of Portable Life Support System (PLSS) for the extra-vehicular mobility unit (EMU) is underway. NASA at Johnson Space Center built and tested an integrated PLSS test bed of all subsystems under a variety of simulated EVA conditions of which the RCA prototype played a significant role. The efforts documented herein summarize RCA test performance and simulation results for single and variable metabolic rate experiments in an integrated context. In addition, a variety of off-nominal tests were performed to assess the capability of the RCA to function under challenging circumstances. Tests included high water production experiments, degraded vacuum regeneration, and deliberate valve/power failure and recovery.
Shade, Brandon C; Schiavo, Kellie; Rosenthal, Tami; Connelly, James T; Melchior, Richard W
2016-06-05
Recent advances in blood pump technology have led to an increased use of centrifugal pumps for prolonged extracorporeal membrane oxygenation (ECMO). Data from the Extracorporeal Life Support Organization confirms that many institutions have converted to centrifugal pumps after prior experience with roller pump technology. Centrifugal pump technology is more compact and may generate less heat and hemolysis than a conventional roller pump. Based on the potential advantages of centrifugal pumps, a decision was made institution-wide to convert to centrifugal pump technology in pediatric implementation of ECMO. Based on limited prior experience with centrifugal pumps, a multidisciplinary approach was used to implement this new technology. The new centrifugal pump (Sorin Revolution, Arvada, CO) was intended for ECMO support in the cardiac intensive care unit (CICU), the pediatric intensive care unit (PICU) and the neonatal intensive care unit (NICU). The perfusion team used their knowledge and expertise with centrifugal pumps to create the necessary teaching tools and interactive training sessions for the technical specialists who consisted primarily of registered nurses and respiratory therapists. The first phase consisted of educating all personnel involved in the care of the ECMO patient, followed by patient implementation in the CICU, followed by the PICU and NICU. The institution-wide conversion took several months to complete and was well received among all disciplines in the CICU and PICU. The NICU personnel did use the centrifugal pump circuit, but decided to revert back to using the roller pump technology. A systematic transition from roller pump to centrifugal pump technology with a multidisciplinary team can ensure a safe and successful implementation. © The Author(s) 2016.
Advance Planning of Form Properties in the Written Production of Single and Multiple Words
ERIC Educational Resources Information Center
Damian, Markus F.; Stadthagen-Gonzalez, Hans
2009-01-01
Three experiments investigated the scope of advance planning in written production. Experiment 1 manipulated phonological factors in single word written production, and Experiments 2 and 3 did the same in the production of adjective-noun utterances. In all three experiments, effects on latencies were found which mirrored those previously…
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
The most common method of measuring air leakage is to perform single (or solo) blower door pressurization and/or depressurization test. In detached housing, the single blower door test measures leakage to the outside. In attached housing, however, this "solo" test method measures both air leakage to the outside and air leakage between adjacent units through common surfaces. Although minimizing leakage to neighboring units is highly recommended to avoid indoor air quality issues between units, reduce pressure differentials between units, and control stack effect, the energy benefits of air sealing can be significantly overpredicted if the solo air leakage number ismore » used in the energy analysis. Guarded blower door testing is more appropriate for isolating and measuring leakage to the outside in attached housing. This method uses multiple blower doors to depressurize adjacent spaces to the same level as the unit being tested. Maintaining a neutral pressure across common walls, ceilings, and floors acts as a "guard" against air leakage between units. The resulting measured air leakage in the test unit is only air leakage to the outside. Although preferred for assessing energy impacts, the challenges of performing guarded testing can be daunting.« less
Demir, Yurdanur; Korhan, Esra Akin; Eser, Ismet; Khorshid, Leyla
2013-07-01
To determine the factors affecting a patient's intensive care experience. The descriptive study was conducted at an intensive care unit in the Aegean Region of Turkey, and comprised 158 patients who spent at least 48 hours at the unit between June and November 2009. A questionnaire form and the Intensive Care Experience Scale were used as data collection tools. SPSS 11.5 was used for statistical analysis of the data. Of the total, 86 (54.4%) patients related to the surgical unit, while 72 (45.5%) spent time at the intensive care unit. Most of the subjects (n=113; 71.5%) reported that they constantly experienced pain during hospitalisation. Patients receiving mechanical ventilation support and patients reporting no pain had significantly higher scores on the intensive care experience scale. Patients who reported pain remembered their experiences less than those having no pain. Interventions are needed to make the experiences of patients in intensive care more positive.
NASA Astrophysics Data System (ADS)
Bernard, John Charles
The objective of this study was to compare the performance of five single sided auctions that could be used in restructured electric power markets across different market sizes in a multiple unit setting. Auction selection would profoundly influence an industry over $200 billion in size in the United States, and the consequences of implementing an inappropriate mechanism would be great. Experimental methods were selected to analyze the auctions. Two rounds of experiments were conducted, the first testing the sealed offer last accepted offer (LAO) and first rejected offer (FRO), and the clock English (ENG) and sealed offer English (SOE) in markets of sizes two and six. The FRO, SOE, and ENG used the same pricing rule. Second round testing was on the LAO, FRO, and the nonuniform price multiple unit Vickrey (MUV) in markets of sizes two, four, and six. Experiments lasted 23 and 75 periods for rounds 1 and 2 respectively. Analysis of variance and contrast analysis were used to examine the data. The four performance measures used were price, efficiency, profits per unit, and supply revelation. Five basic principles were also assessed: no sales at losses, all low cost capacity should be offered and sold, no high cost capacity should sell, and the market should clear. It was expected group size and auction type would affect performance. For all performance measures, group size was a significant variable, with smaller groups showing poorer performance. Auction type was significant only for the efficiency performance measure, where clock auctions outperformed the others. Clock auctions also proved superior for the first four principles. The FRO performed poorly in almost all situations, and should not be a preferred mechanism in any market. The ENG was highly efficient, but expensive for the buyer. The SOE appeared superior to the FRO and ENG. The clock improves efficiency over the FRO while less information kept prices under the ENG. The MUV was superior in revealing costs, but performed less well in other categories. While concerns existed for all the mechanisms investigated, the commonly proposed LAO was the best option for restructured electric power markets.
ERIC Educational Resources Information Center
Admire, Myron
This curriculum guide to the Supervised Agricultural Experience (SAE) program contains four units of insturctor's materials as follows: Unit 1: Developing an SAE Program; Unit 2: Using the Missouri Agricultural Record Book for Secondary Students; Unit 3: Analyzing the SAE Program; and Unit 4: Using the Missouri Farm Business Record Book. The…
The proximate unit in Chinese handwritten character production
Chen, Jenn-Yeu; Cherng, Rong-Ju
2013-01-01
In spoken word production, a proximate unit is the first phonological unit at the sublexical level that is selectable for production (O'Seaghdha et al., 2010). The present study investigated whether the proximate unit in Chinese handwritten character production is the stroke, the radical, or something in between. A written version of the form preparation task was adopted. Chinese participants learned sets of two-character words, later were cued with the first character of each word, and had to write down the second character (the target). Response times were measured from the onset of a cue character to the onset of a written response. In Experiment 1, the target characters within a block shared (homogeneous) or did not share (heterogeneous) the first stroke. In Experiment 2, the first two strokes were shared in the homogeneous blocks. Response times in the homogeneous blocks and in the heterogeneous blocks were comparable in both experiments (Experiment 1: 687 vs. 684 ms, Experiment 2: 717 vs. 716). In Experiment 3 and 4, the target characters within a block shared or did not share the first radical. Response times in the homogeneous blocks were significantly faster than those in the heterogeneous blocks (Experiment 3: 685 vs. 704, Experiment 4: 594 vs. 650). In Experiment 5 and 6, the shared component was a Gestalt-like form that is more than a stroke, constitutes a portion of the target character, can be a stand-alone character itself, can be a radical of another character but is not a radical of the target character (e.g., ± in , , , ; called a logographeme). Response times in the homogeneous blocks were significantly faster than those in the heterogeneous blocks (Experiment 5: 576 vs. 625, Experiment 6: 586 vs. 620). These results suggest a model of Chinese handwritten character production in which the stroke is not a functional unit, the radical plays the role of a morpheme, and the logographeme is the proximate unit. PMID:23950752
Brahim, Bessem; Tabet, Jean-Claude; Alves, Sandra
2018-02-01
Gas-phase fragmentation of single strand DNA-peptide noncovalent complexes is investigated in positive and negative electrospray ionization modes.Collision-induced dissociation experiments, performed on the positively charged noncovalent complex precursor ions, have confirmed the trend previously observed in negative ion mode, i.e. a high stability of noncovalent complexes containing very basic peptidic residues (i.e. R > K) and acidic nucleotide units (i.e. Thy units), certainly incoming from the existence of salt bridge interactions. Independent of the ion polarity, stable noncovalent complex precursor ions were found to dissociate preferentially through covalent bond cleavages of the partners without disrupting noncovalent interactions. The resulting DNA fragment ions were found to be still noncovalently linked to the peptides. Additionally, the losses of an internal nucleic fragment producing "three-body" noncovalent fragment ions were also observed in both ion polarities, demonstrating the spectacular salt bridge interaction stability. The identical fragmentation patterns (regardless of the relative fragment ion abundances) observed in both polarities have shown a common location of salt bridge interaction certainly preserved from solution. Nonetheless, most abundant noncovalent fragment ions (and particularly three-body ones) are observed from positively charged noncovalent complexes. Therefore, we assume that, independent of the preexisting salt bridge interaction and zwitterion structures, multiple covalent bond cleavages from single-stranded DNA/peptide complexes rely on an excess of positive charges in both electrospray ionization ion polarities.
Kalaitzis, John A; Cheng, Qian; Meluzzi, Dario; Xiang, Longkuan; Izumikawa, Miho; Dorrestein, Pieter C; Moore, Bradley S
2011-11-15
Enterocin is an atypical type II polyketide synthase (PKS) product from the marine actinomycete 'Streptomyces maritimus'. The enterocin biosynthesis gene cluster (enc) codes for proteins involved in the assembly and attachment of the rare benzoate primer that initiates polyketide assembly with the addition of seven malonate molecules and culminates in a Favorskii-like rearrangement of the linear poly-β-ketone to give its distinctive non-aromatic, caged core structure. Fundamental to enterocin biosynthesis, which utilizes a single acyl carrier protein (ACP), EncC, for both priming with benzoate and elongating with malonate, involves maintaining the correct balance of acyl-EncC substrates for efficient polyketide assembly. Here, we report the characterization of EncL as a type II thioesterase that functions to edit starter unit (mis)priming of EncC. We performed a series of in vivo mutational studies, heterologous expression experiments, in vitro reconstitution studies, and Fourier-transform mass spectrometry-monitored competitive enzyme assays that together support the proposed selective hydrolase activity of EncL toward misprimed acetyl-ACP over benzoyl-ACP to facilitate benzoyl priming of the enterocin PKS complex. While this system resembles the R1128 PKS that also utilizes an editing thioesterase (ZhuC) to purge acetate molecules from its initiation module ACP in favor of alkylacyl groups, the enterocin system is distinct in its usage of a single ACP for both priming and elongating reactions with different substrates. Copyright © 2011 Elsevier Ltd. All rights reserved.
Kalaitzis, John A.; Cheng, Qian; Meluzzi, Dario; Xiang, Longkuan; Izumikawa, Miho; Dorrestein, Pieter C.; Moore, Bradley S.
2011-01-01
Enterocin is an atypical type II polyketide synthase (PKS) product from the marine actinomycete “Streptomyces maritimus”. The enterocin biosynthesis gene cluster (enc) codes for proteins involved in the assembly and attachment of the rare benzoate primer that initiates polyketide assembly with the addition of seven malonate molecules and culminates in a Favorskii-like rearrangement of the linear poly-β-ketone to give its distinctive non-aromatic, caged core structure. Fundamental to enterocin biosynthesis, which utilizes a single acyl carrier protein (ACP), EncC, for both priming with benzoate and elongating with malonate, involves maintaining the correct balance of acyl-EncC substrates for efficient polyketide assembly. Here we report the characterization of EncL as a type II thioesterase that functions to edit starter unit (mis)priming of EncC. We performed a series of in vivo mutational studies, heterologous expression experiments, in vitro reconstitution studies, and Fourier-transform mass spectrometry-monitored competitive enzyme assays that together support the proposed selective hydrolase activity of EncL toward misprimed acetyl-ACP over benzoyl-ACP to facilitate benzoyl priming of the enterocin PKS complex. While this system resembles the R1128 PKS that also utilizes an editing thioesterase (ZhuC) to purge acetate molecules from its initiation module ACP in favor of alkylacyl groups, the enterocin system is distinct in its usage of a single ACP for both priming and elongating reactions with different substrates. PMID:21531566
Lao, Lifeng; Cohen, Jeremiah R.; Buser, Zorica; Brodke, Darrel S.; Yoon, S. Tim; Youssef, Jim A.; Park, Jong-Beom; Meisel, Hans-Joerg; Wang, Jeffrey C.
2017-01-01
Study Design: Retrospective case study. Objective: To evaluate the trends and demographics of recombinant human bone morphogenetic protein 2 (rhBMP2) utilization in single-level anterior lumbar interbody fusion (ALIF) in the United States. Methods: Patients who underwent single-level ALIF from 2005 to 2011 were identified by searching ICD-9 diagnosis and procedure codes in the PearlDiver Patient Records Database (PearlDiver Technologies, Fort Wayne, IN), a national database of orthopedic insurance records. The year of procedure, age, gender, and region of the United States were analyzed for each patient. Results: A total of 921 patients were identified who underwent a single-level ALIF in this study. The average rate of single-level ALIF with rhBMP2 utilization increased (35%-48%) from 2005 to 2009, but sharply decreased to 16.7% in 2010 and 15.0% in 2011. The overall incidence of single-level ALIF without rhBMP2 (0.20 cases per 100 000 patients) was more than twice of the incidence of single-level ALIF with rhBMP2 (0.09 cases per 100 000 patients). The average rate of single-level ALIF with rhBMP2 utilization is highest in West (41.4%), followed by Midwest (33.3%), South (26.5%) and Northeast (22.2%). The highest incidence of single-level ALIF with rhBMP2 was observed in the group aged less than 65 years (compared with any other age groups, P < .001), with an incidence of 0.21 per 100 000 patients. Conclusions: The incidence of rhBMP2 utilization in single-level ALIF increased from 2006 to 2009, but decreased in 2010 and 2011. The Northeast region had the lowest incidence of rhBMP2 utilization. The group aged less than 65 years trended to have the higher incidence of single-level ALIF with rhBMP2 utilization. PMID:29662743
Lao, Lifeng; Cohen, Jeremiah R; Buser, Zorica; Brodke, Darrel S; Yoon, S Tim; Youssef, Jim A; Park, Jong-Beom; Meisel, Hans-Joerg; Wang, Jeffrey C
2018-04-01
Retrospective case study. To evaluate the trends and demographics of recombinant human bone morphogenetic protein 2 (rhBMP2) utilization in single-level anterior lumbar interbody fusion (ALIF) in the United States. Patients who underwent single-level ALIF from 2005 to 2011 were identified by searching ICD-9 diagnosis and procedure codes in the PearlDiver Patient Records Database (PearlDiver Technologies, Fort Wayne, IN), a national database of orthopedic insurance records. The year of procedure, age, gender, and region of the United States were analyzed for each patient. A total of 921 patients were identified who underwent a single-level ALIF in this study. The average rate of single-level ALIF with rhBMP2 utilization increased (35%-48%) from 2005 to 2009, but sharply decreased to 16.7% in 2010 and 15.0% in 2011. The overall incidence of single-level ALIF without rhBMP2 (0.20 cases per 100 000 patients) was more than twice of the incidence of single-level ALIF with rhBMP2 (0.09 cases per 100 000 patients). The average rate of single-level ALIF with rhBMP2 utilization is highest in West (41.4%), followed by Midwest (33.3%), South (26.5%) and Northeast (22.2%). The highest incidence of single-level ALIF with rhBMP2 was observed in the group aged less than 65 years (compared with any other age groups, P < .001), with an incidence of 0.21 per 100 000 patients. The incidence of rhBMP2 utilization in single-level ALIF increased from 2006 to 2009, but decreased in 2010 and 2011. The Northeast region had the lowest incidence of rhBMP2 utilization. The group aged less than 65 years trended to have the higher incidence of single-level ALIF with rhBMP2 utilization.
On Integration and Validation of a Very Low Complexity ATC UWB System for Muscle Force Transmission.
Sapienza, Stefano; Crepaldi, Marco; Motto Ros, Paolo; Bonanno, Alberto; Demarchi, Danilo
2016-04-01
The thresholding of Surface ElectroMyoGraphic (sEMG) signals, i.e., Average Threshold Crossing (ATC) technique, reduces the amount of data to be processed enabling circuit complexity reduction and low power consumption. This paper investigates the lowest level of complexity reachable by an ATC system through measurements and in-vivo experiments with an embedded prototype for wireless force transmission, based on asynchronous Impulse-Radio Ultra Wide Band (IR-UWB). The prototype is composed by the acquisition unit, a wearable PCB 23 × 34 mm, which includes a full custom IC integrating a UWB transmitter (chip active silicon area 0.016 mm(2), 1 mW power consumption), and the receiver. The system is completely asynchronous, it acquires a differential sEMG signal, generates the ATC events and triggers a 3.3 GHz IR-UWB transmission. ATC robustness relaxes filters constraints: two passive first order filters have been implemented, bandwidth from 10 Hz up to 1 kHz. Energy needed for the single pulse generation is 30 pJ while the whole PCB consumes 5.65 mW. The pulses radiated by the acquisition unit TX are received by a short-range and low complexity threshold-based 130 nm CMOS IR-UWB receiver with an Ultra Low Power (ULP) baseband unit capable of robustly receiving generic quasi-digital pulse sequences. The acquisition unit have been tested with 10 series of in vivo isometric and isotonic contractions, while the transmission channel with over-the-air and cable measurements obtained with a couple of planar monopole antennas and an integrated 0.004 mm(2) transmitter, the same used for the acquisition unit, with realistic channel conditions. The entire system, acquisition unit and receiver, consumes 15.49 mW.
Ogunsiji, Olayide; Wilkes, Lesley
Evidence suggests that single parent families are more likely to be affected by social problems associated with poor health and poverty. Single parent families are growing in number and are overwhelmingly headed by women. Despite their increasing number and their level of vulnerability, the lived experiences of single mothers have attracted little attention in the literature. Still little is known about many aspects of life as experienced by single mothers. Nursing is a profession that is dominated by women, and every year a number of single mothers enroll in undergraduate nurse education programs. Currently, there is little information about the experiences of women who are single mothers, undertaking a nursing degree in a university. This paper reports a study that explored the lived experiences of five single mother undergraduate nursing students. van Manen's phenomenological method informed the design and conduct of the study. Findings were grouped into the following themes: being exhausted all the time; being overwhelmed with worries; and being hopeful of the future. Findings of this study revealed that the single mothers' major health concerns were chronic tiredness and overwhelming worries. However, their being in the university was perceived as being health promoting and restoring to their self-esteem. Implications for educators, health providers and women's health services are drawn from the findings.
NASA Astrophysics Data System (ADS)
Hu, C. Y.
2016-12-01
The realization of quantum computers and quantum Internet requires not only quantum gates and quantum memories, but also transistors at single-photon levels to control the flow of information encoded on single photons. Single-photon transistor (SPT) is an optical transistor in the quantum limit, which uses a single photon to open or block a photonic channel. In sharp contrast to all previous SPT proposals which are based on single-photon nonlinearities, here I present a design for a high-gain and high-speed (up to THz) SPT based on a linear optical effect: giant circular birefringence induced by a single spin in a double-sided optical microcavity. A gate photon sets the spin state via projective measurement and controls the light propagation in the optical channel. This spin-cavity transistor can be directly configured as diodes, routers, DRAM units, switches, modulators, etc. Due to the duality as quantum gate and transistor, the spin-cavity unit provides a solid-state platform ideal for future Internet: a mixture of all-optical Internet with quantum Internet.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baring-Gould, E. Ian; Christol, Corrie; LiVecchi, Al
In 2014 and 2015, the U.S. Department of Energy initiated efforts to develop and implement technology- and application-focused marine and hydrokinetic (MHK) workshops to share the global experience and knowledge base on evolving MHK technologies, observed and not-observed impacts, monitoring and measurement methods, and regulatory needs. The resulting MHK Regulator Workshops engaged resource managers and other decision makers at key regulatory organizations, scientists, researchers, facilitators, and technical experts and provided an opportunity to examine the risks of single-device and small-scale deployments, explore what can be learned and observed from single devices and small-scale arrays, and consider requirements for projects atmore » varying scales of deployment. Experts and stakeholders identified key remaining information gaps. Initial discussions focused on differentiating between monitoring required for single or small-scale deployments and MHK impact research that, although important, goes beyond what is feasible or should be needed to meet specific project regulatory requirements but is appropriate for broader research and development. Four areas of identified potential environmental impacts provided the focus for the workshop: acoustic output impacts, electromagnetic field (EMF) emissions, physical interactions, and environmental effects of MHK energy development on the physical environment. Discussions also focused on the regulatory process and experience, adaptive management, industry drivers, and lessons that can be learned from the wind energy industry. The discussion was set in the context of the types of MHK technologies that are currently proposed or planned in the United States. All presentations and the following discussions are summarized in this document.« less
Molina, Yamile; Marquez, Jacob H.; Logan, Diane E.; Leeson, Carissa J.; Balsam, Kimberly F.; Kaysen, Debra L.
2015-01-01
Current intimate relationship characteristics, including gender and number of partner(s), may affect one's visibility as a bisexual individual and the minority stressors they experience, which may in turn influence their health. The current study tested four hypotheses: 1) minority stressors vary by current intimate relationship status; 2) higher minority stressors are associated with higher depressive symptoms and alcohol-related outcomes; 3) depressive symptoms and alcohol-related outcomes vary by current intimate relationship status; and 4) minority stressors will mediate differences in these outcomes. Participants included 470 self-identified bisexual women (65% Caucasian, mean age: 21) from a sample of sexual minority women recruited from different geographic regions in the United States through advertisements on social networking sites and Craigslist. Participants completed a 45 minute survey. Respondents with single partners were first grouped by partner gender (male partner: n=282; female partner: n=56). Second, women were grouped by partner gender/number (single female/male partner: n = 338; women with multiple female and male partners: n=132). Women with single male partners and women with multiple male and female partners exhibited elevated experienced bi-negativity and differences in outness (H1). Experienced and internalized bi-negativity were associated with health outcomes, but not outness (H2). Differences in outcomes emerged by partner number and partner number/gender (H3); these differences were mediated by experienced bi-negativity (H4). These results suggest that experiences of discrimination may underlie differences in health related to bisexual women's relationship structure and highlight the importance of evaluating women's relational context as well as sexual identification in understanding health risk behaviors. PMID:26456995
Molina, Yamile; Marquez, Jacob H; Logan, Diane E; Leeson, Carissa J; Balsam, Kimberly F; Kaysen, Debra L
2015-07-01
Current intimate relationship characteristics, including gender and number of partner(s), may affect one's visibility as a bisexual individual and the minority stressors they experience, which may in turn influence their health. The current study tested four hypotheses: 1) minority stressors vary by current intimate relationship status; 2) higher minority stressors are associated with higher depressive symptoms and alcohol-related outcomes; 3) depressive symptoms and alcohol-related outcomes vary by current intimate relationship status; and 4) minority stressors will mediate differences in these outcomes. Participants included 470 self-identified bisexual women (65% Caucasian, mean age: 21) from a sample of sexual minority women recruited from different geographic regions in the United States through advertisements on social networking sites and Craigslist. Participants completed a 45 minute survey. Respondents with single partners were first grouped by partner gender (male partner: n=282; female partner: n=56). Second, women were grouped by partner gender/number (single female/male partner: n = 338; women with multiple female and male partners: n=132). Women with single male partners and women with multiple male and female partners exhibited elevated experienced bi-negativity and differences in outness (H1). Experienced and internalized bi-negativity were associated with health outcomes, but not outness (H2). Differences in outcomes emerged by partner number and partner number/gender (H3); these differences were mediated by experienced bi-negativity (H4). These results suggest that experiences of discrimination may underlie differences in health related to bisexual women's relationship structure and highlight the importance of evaluating women's relational context as well as sexual identification in understanding health risk behaviors.
Yerrabothala, Swaroopa; Desrosiers, Kevin P; Szczepiorkowski, Zbigniew M; Dunbar, Nancy M
2014-10-01
Our hospital transfusion policy was recently revised to recommend single-unit red blood cell transfusion (RBC TXN) for nonbleeding inpatients when the hemoglobin (Hb) level is not more than 7 g/dL. Our computerized provider order entry system was reconfigured to provide real-time decision support using prospective computerized order auditing based on the most recent Hb level and to remove the single-click ordering option for 2-unit RBC TXNs to enhance compliance. This study was undertaken to assess the impact of these changes on hospital transfusion practice. This study analyzed the total number of transfusion events, proportion of single and 2-unit transfusions and the Hb transfusion trigger in the preimplementation period (October 2011-March 2012) compared to the postimplementation period (October 2012-March 2013). In the postimplementation period the total number of RBC units transfused/1000 patient-days decreased from 60.8 to 44.2 (p < 0.0001). The proportion of 2-unit TXNs decreased from 47% to 15% (p < 0.0001). We also observed significant decreases in pretransfusion Hb triggers. Implementation of restrictive transfusion policy supported by prospective computerized order auditing has resulted in significantly decreased RBC utilization at our institution. © 2014 AABB.
Isomeric Character of the Lowest Observed 4+ State in 44S
NASA Astrophysics Data System (ADS)
Parker, J. J.; Wiedenhöver, I.; Cottle, P. D.; Baker, J.; McPherson, D.; Riley, M. A.; Santiago-Gonzalez, D.; Volya, A.; Bader, V. M.; Baugher, T.; Bazin, D.; Gade, A.; Ginter, T.; Iwasaki, H.; Loelius, C.; Morse, C.; Recchia, F.; Smalley, D.; Stroberg, S. R.; Whitmore, K.; Weisshaar, D.; Lemasson, A.; Crawford, H. L.; Macchiavelli, A. O.; Wimmer, K.
2017-02-01
Previous experiments observed a 4+ state in the N =28 nucleus 44S and suggested that this state may exhibit a hindered E 2 -decay rate, inconsistent with being a member of the collective ground state band. We populate this state via two-proton knockout from a beam of exotic 46Ar projectiles and measure its lifetime using the recoil distance method with the GRETINA γ -ray spectrometer. The result, 76 (14 )stat(20 )syst ps , implies a hindered transition of B (E 2 ;4+→21+)=0.61 (19 ) single-particle or Weisskopf units strength and supports the interpretation of the 4+ state as a K =4 isomer, the first example of a high-K isomer in a nucleus of such low mass.
1998-09-02
During a break in the Crew Equipment Interface Test (CEIT) at KSC, Payload Specialist John H. Glenn Jr., a senator from Ohio, poses for a photo with Georgett Styers, United Space Alliance receiving scheduler, NASA Supply Logistics Depot, Cape Canaveral, Fla. The CEIT gives astronauts an opportunity for a hands-on look at the payloads and equipment with which they will be working on orbit. The launch of the STS-95 mission is scheduled for Oct. 29, 1998, on the Space Shuttle Discovery. The mission includes research payloads such as the Spartan solar-observing deployable spacecraft, the Hubble Space Telescope Orbital Systems Test Platform, the International Extreme Ultraviolet Hitchhiker, as well as the SPACEHAB single module with experiments on space flight and the aging process
Kim, Sung-Cheol; Wunsch, Benjamin H; Hu, Huan; Smith, Joshua T; Austin, Robert H; Stolovitzky, Gustavo
2017-06-27
Deterministic lateral displacement (DLD) is a technique for size fractionation of particles in continuous flow that has shown great potential for biological applications. Several theoretical models have been proposed, but experimental evidence has demonstrated that a rich class of intermediate migration behavior exists, which is not predicted. We present a unified theoretical framework to infer the path of particles in the whole array on the basis of trajectories in a unit cell. This framework explains many of the unexpected particle trajectories reported and can be used to design arrays for even nanoscale particle fractionation. We performed experiments that verify these predictions and used our model to develop a condenser array that achieves full particle separation with a single fluidic input.
Universal mechanism of thermo-mechanical deformation in metallic glasses
Dmowski, W.; Tong, Y.; Iwashita, T.; ...
2015-02-11
Here we investigated the atomistic structure of metallic glasses subjected to thermo-mechanical creep deformation using high energy x-ray diffraction and molecular dynamics simulation. The experiments were performed in-situ, at high temperatures as a time dependent deformation in the elastic regime, and ex-situ on samples quenched under stress. We show that all the anisotropic structure functions of the samples undergone thermo-mechanical creep can be scaled into a single curve, regardless of the magnitude of anelastic strain, stress level and the sign of the stress, demonstrating universal behavior and pointing to unique atomistic unit of anelastic deformation. The structural changes due tomore » creep are strongly localized within the second nearest neighbors, involving only a small group of atoms.« less
1998-09-02
(Left to right) STS-95 Payload Specialists John H. Glenn Jr., senator from Ohio, and Chiaki Mukai, with the National Space Development Agency of Japan, talk with Kiki Chaput, trainer, United Space Alliance-Houston, during the Crew Equipment Interface Test (CEIT) for their mission. The CEIT gives astronauts an opportunity for a hands-on look at the payloads on whcih they will be working on orbit. The launch of the STS-95 mission, aboard Space Shuttle Discovery, is scheduled for Oct. 29, 1998. The mission includes research payloads such as the Spartan solar-observing deployable spacecraft, the Hubble Space Telescope Orbital Systems Test Platform, the International Extreme Ultraviolet Hitchhiker, as well as the SPACEHAB single module with experiments on space flight and the aging process
Evolving mobile robots able to display collective behaviors.
Baldassarre, Gianluca; Nolfi, Stefano; Parisi, Domenico
2003-01-01
We present a set of experiments in which simulated robots are evolved for the ability to aggregate and move together toward a light target. By developing and using quantitative indexes that capture the structural properties of the emerged formations, we show that evolved individuals display interesting behavioral patterns in which groups of robots act as a single unit. Moreover, evolved groups of robots with identical controllers display primitive forms of situated specialization and play different behavioral functions within the group according to the circumstances. Overall, the results presented in the article demonstrate that evolutionary techniques, by exploiting the self-organizing behavioral properties that emerge from the interactions between the robots and between the robots and the environment, are a powerful method for synthesizing collective behavior.
50 CFR 25.53 - Establishment of single visit entrance fees.
Code of Federal Regulations, 2010 CFR
2010-10-01
... fees. 25.53 Section 25.53 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR (CONTINUED) THE NATIONAL WILDLIFE REFUGE SYSTEM ADMINISTRATIVE PROVISIONS Fees and Charges § 25.53 Establishment of single visit entrance fees. Entrance fees established for single visit...