Sample records for sit camera system

  1. Remote gaze tracking system on a large display.

    PubMed

    Lee, Hyeon Chang; Lee, Won Oh; Cho, Chul Woo; Gwon, Su Yeong; Park, Kang Ryoung; Lee, Heekyung; Cha, Jihun

    2013-10-07

    We propose a new remote gaze tracking system as an intelligent TV interface. Our research is novel in the following three ways: first, because a user can sit at various positions in front of a large display, the capture volume of the gaze tracking system should be greater, so the proposed system includes two cameras which can be moved simultaneously by panning and tilting mechanisms, a wide view camera (WVC) for detecting eye position and an auto-focusing narrow view camera (NVC) for capturing enlarged eye images. Second, in order to remove the complicated calibration between the WVC and NVC and to enhance the capture speed of the NVC, these two cameras are combined in a parallel structure. Third, the auto-focusing of the NVC is achieved on the basis of both the user's facial width in the WVC image and a focus score calculated on the eye image of the NVC. Experimental results showed that the proposed system can be operated with a gaze tracking accuracy of ±0.737°~±0.775° and a speed of 5~10 frames/s.

  2. Remote Gaze Tracking System on a Large Display

    PubMed Central

    Lee, Hyeon Chang; Lee, Won Oh; Cho, Chul Woo; Gwon, Su Yeong; Park, Kang Ryoung; Lee, Heekyung; Cha, Jihun

    2013-01-01

    We propose a new remote gaze tracking system as an intelligent TV interface. Our research is novel in the following three ways: first, because a user can sit at various positions in front of a large display, the capture volume of the gaze tracking system should be greater, so the proposed system includes two cameras which can be moved simultaneously by panning and tilting mechanisms, a wide view camera (WVC) for detecting eye position and an auto-focusing narrow view camera (NVC) for capturing enlarged eye images. Second, in order to remove the complicated calibration between the WVC and NVC and to enhance the capture speed of the NVC, these two cameras are combined in a parallel structure. Third, the auto-focusing of the NVC is achieved on the basis of both the user's facial width in the WVC image and a focus score calculated on the eye image of the NVC. Experimental results showed that the proposed system can be operated with a gaze tracking accuracy of ±0.737°∼±0.775° and a speed of 5∼10 frames/s. PMID:24105351

  3. Detection of Suspicious Persons using Internet Camera

    NASA Astrophysics Data System (ADS)

    Terada, Kenji; Kamogashira, Daisuke

    Recently, many brutal crimes have shocked us. Therefore, the importance of security and self-defense have increased more and more. It is necessary to develop an automatic method of detecting suspicious persons. In this paper, we propose a method of detecting suspicious persons using the internet camera. An image sequence is obtained by the internet camera. By using these images, the recognition of suspicious persons is carried out. Our method classifies the condition of the target person into 3 postures: walking, staying and sitting. The system employs the subspace method which uses three features: the value of movement, the number of looking around restlessly, and the rate of stopping and going. Some experimental results using a simple experimental system are also reported, which indicate effectiveness of the proposed method. In most scenes, the suspicious persons are able to be detected by the proposed method.

  4. Renal Scintigraphy

    MedlinePlus

    ... in your hand or arm. When it is time for the imaging to begin, the gamma camera will take a series of images. The camera may rotate around you or it may stay in one position and you will be asked to change positions in ... to remain still for brief periods of time. You may be asked to sit or lie ...

  5. Driver face recognition as a security and safety feature

    NASA Astrophysics Data System (ADS)

    Vetter, Volker; Giefing, Gerd-Juergen; Mai, Rudolf; Weisser, Hubert

    1995-09-01

    We present a driver face recognition system for comfortable access control and individual settings of automobiles. The primary goals are the prevention of car thefts and heavy accidents caused by unauthorized use (joy-riders), as well as the increase of safety through optimal settings, e.g. of the mirrors and the seat position. The person sitting on the driver's seat is observed automatically by a small video camera in the dashboard. All he has to do is to behave cooperatively, i.e. to look into the camera. A classification system validates his access. Only after a positive identification, the car can be used and the driver-specific environment (e.g. seat position, mirrors, etc.) may be set up to ensure the driver's comfort and safety. The driver identification system has been integrated in a Volkswagen research car. Recognition results are presented.

  6. Earth observation

    NASA Image and Video Library

    2014-09-04

    ISS040-E-129950 (4 Sept. 2014) --- In this photograph. taken by one of the Expedition 40 crew members aboard the Earth-orbiting International Space Station, the orange spot located in the very center is the sun, which appears to be sitting on Earth's limb. At far right, a small bright spot is believed to be a reflection from somewhere in the camera system or something on the orbital outpost. When the photographed was exposed, the orbital outpost was flying at an altutude of 226 nautical miles above a point near French Polynesia in the Pacific Ocean.

  7. Fusion of thermal- and visible-band video for abandoned object detection

    NASA Astrophysics Data System (ADS)

    Beyan, Cigdem; Yigit, Ahmet; Temizel, Alptekin

    2011-07-01

    Timely detection of packages that are left unattended in public spaces is a security concern, and rapid detection is important for prevention of potential threats. Because constant surveillance of such places is challenging and labor intensive, automated abandoned-object-detection systems aiding operators have started to be widely used. In many studies, stationary objects, such as people sitting on a bench, are also detected as suspicious objects due to abandoned items being defined as items newly added to the scene and remained stationary for a predefined time. Therefore, any stationary object results in an alarm causing a high number of false alarms. These false alarms could be prevented by classifying suspicious items as living and nonliving objects. In this study, a system for abandoned object detection that aids operators surveilling indoor environments such as airports, railway or metro stations, is proposed. By analysis of information from a thermal- and visible-band camera, people and the objects left behind can be detected and discriminated as living and nonliving, reducing the false-alarm rate. Experiments demonstrate that using data obtained from a thermal camera in addition to a visible-band camera also increases the true detection rate of abandoned objects.

  8. KSC-00pp0858

    NASA Image and Video Library

    2000-06-29

    Inside the Vehicle Assembly Building, the forward section of a solid rocket booster (SRB) sits on top of the rest of the stack for mating. The forward section of each booster, from nose cap to forward skirt contains avionics, a sequencer, forward separation motors, a nose cone separation system, drogue and main parachutes, a recovery beacon, a recovery light, a parachute camera on selected flights and a range safety system. Each SRB weighs approximately 1.3 million pounds at launch. The SRB is part of the stack for Space Shuttle Discovery and the STS-92 mission, scheduled for launch Oct. 5, from Launch Pad 39A, on the fifth flight to the International Space Station

  9. KSC00pp0858

    NASA Image and Video Library

    2000-06-29

    Inside the Vehicle Assembly Building, the forward section of a solid rocket booster (SRB) sits on top of the rest of the stack for mating. The forward section of each booster, from nose cap to forward skirt contains avionics, a sequencer, forward separation motors, a nose cone separation system, drogue and main parachutes, a recovery beacon, a recovery light, a parachute camera on selected flights and a range safety system. Each SRB weighs approximately 1.3 million pounds at launch. The SRB is part of the stack for Space Shuttle Discovery and the STS-92 mission, scheduled for launch Oct. 5, from Launch Pad 39A, on the fifth flight to the International Space Station

  10. Sit-to-stand movement changes in preschool-aged children with spastic diplegia following one neurodevelopmental treatment session--a pilot study.

    PubMed

    Yonetsu, Ryo; Iwata, Akira; Surya, John; Unase, Kazunori; Shimizu, Junichi

    2015-01-01

    This study was designed to provide a better understanding of how a single neurodevelopmental treatment (NDT) session affects sit-to-stand (STS) movements in children with cerebral palsy (CP). Eight children with spastic diplegia and five typically developing children, aged 4-6 years, participated in this study. The CP participants performed STS movements immediately before and after a 40-min NDT session. Using a three-dimensional, four-camera analysis system, angular movements involving the hip, knee and ankle joints of the participants were obtained. During forward tilt of the trunk, the maximum and final angles after the NDT session significantly decreased compared with those before the session (p < 0.05, p < 0.01). Moreover, the final hip flexion after the session also significantly decreased compared with that before the session (p < 0.01). On the other hand, the initial, maximum and final ankle dorsiflexion angles after the session were significantly greater (p < 0.05, p < 0.01 and p < 0.05, respectively) than before the session. These findings suggest that a single NDT session enables children with CP to stand from a seated position without using some atypical movement patterns. Preschool-aged children with spastic diplegia, with limited ability to independently transfer from a sitting position, and dependent on a wheelchair for mobility experience obstacles to enhanced activities of daily life and social participation. A single neurodevelopmental treatment session would enable children with spastic diplegia to perform sit-to-stand movements more efficiently, with selective muscle control. Understanding how a single neurodevelopmental treatment session affects sit-to-stand movements in children with spastic diplegia is invaluable for therapists planning more efficient therapeutic programs and may enable children with spastic diplegia to develop improved mobility.

  11. Automation of Vapor-Diffusion Growth of Protein Crystals

    NASA Technical Reports Server (NTRS)

    Hamrick, David T.; Bray, Terry L.

    2005-01-01

    Some improvements have been made in a system of laboratory equipment developed previously for studying the crystallization of proteins from solution by use of dynamically controlled flows of dry gas. The improvements involve mainly (1) automation of dispensing of liquids for starting experiments, (2) automatic control of drying of protein solutions during the experiments, and (3) provision for automated acquisition of video images for monitoring experiments in progress and for post-experiment analysis. The automation of dispensing of liquids was effected by adding an automated liquid-handling robot that can aspirate source solutions and dispense them in either a hanging-drop or a sitting-drop configuration, whichever is specified, in each of 48 experiment chambers. A video camera of approximately the size and shape of a lipstick dispenser was added to a mobile stage that is part of the robot, in order to enable automated acquisition of images in each experiment chamber. The experiment chambers were redesigned to enable the use of sitting drops, enable backlighting of each specimen, and facilitate automation.

  12. KSC-04pd1224

    NASA Image and Video Library

    2004-05-19

    KENNEDY SPACE CENTER, FLA. -- Johnson Controls operator Rick Wetherington sits in the center console seat of one of the recently acquired Contraves-Goerz Kineto Tracking Mounts (KTM). There are 10 KTMs certified for use on the Eastern Range. The KTM, which is trailer-mounted with an electric drive tracking mount, includes a two-camera, camera control unit that will be used during launches. The KTM is designed for remotely controlled operations and offers a combination of film, shuttered and high-speed digital video, and FLIR cameras configured with 20-inch to 150-inch focal length lenses. The KTMs are generally placed in the field and checked out the day before a launch and manned 3 hours prior to liftoff.

  13. Transabdominal wall deployment for instruments, lights, and micromotors using the concept of secured independent tools.

    PubMed

    Tsin, Daniel A; Davila, Fausto; Dominguez, Guillermo; Tinelli, Andrea; Davila, Martha R

    2012-05-01

    Use of secured independent tools (SIT) is changing the laparoscopy paradigm, which involves the use of instruments inside the abdominal cavity that are operated via a port that is larger in diameter than the instrument itself. However, in SIT instead of ports we used filaments or cables. Here we describe a modified SIT for use in the introduction of sutures or cables inside the peritoneum. Cables or sutures are passed through a tunnel made by an intravenous catheter and then exteriorized via a 12-mm port for tying, plugging (attaching), or connecting to different types of devices such as an endoscopic bulldog, alligator clamps, lights, and micromotors. These devices are introduced inside the abdomen and remotely operated with cables or filaments. The use of SIT is not limited to laparoscopy; it was successfully used in clinical experiences of single-port and single-incision laparoscopy and could facilitate natural orifice surgery. The technique offers a good force for traction, retraction, and mobilization. In addition, it has transmission capabilities for cameras and may facilitate the placement of wired microrobotics.

  14. Rocket instrument for far-UV spectrophotometry of faint astronomical objects.

    PubMed

    Hartig, G F; Fastie, W G; Davidsen, A F

    1980-03-01

    A sensitive sounding rocket instrument for moderate (~10-A) resolution far-UV (lambda1160-lambda1750-A) spectrophotometry of faint astronomical objects has been developed. The instrument employs a photon-counting microchannel plate imaging detector and a concave grating spectrograph behind a 40-cm Dall-Kirkham telescope. A unique remote-control pointing system, incorporating an SIT vidicon aspect camera, two star trackers, and a tone-encoded command telemetry link, permits the telescope to be oriented to within 5 arc sec of any target for which suitable guide stars can be found. The design, construction, calibration, and flight performance of the instrument are discussed.

  15. 'Berries' Here, There, Everywhere

    NASA Technical Reports Server (NTRS)

    2004-01-01

    This approximate true-color image suggests that the plains beyond the small crater where the Mars Exploration Rover Opportunity now sits are littered with the same dark grey material found inside the crater in the form of spherules or 'blueberries.' Because Mars orbiters have observed the iron-bearing mineral hematite across these plains, scientists hypothesize that the blueberries are also made up of this mineral. This image was taken by the rover's panoramic camera on the 17th martian day, or sol, of its mission. Data from the camera's red, green and blue filters were combined to create this image.

  16. Sitting in the Pilot's Seat; Optimizing Human-Systems Interfaces for Unmanned Aerial Vehicles

    NASA Technical Reports Server (NTRS)

    Queen, Steven M.; Sanner, Kurt Gregory

    2011-01-01

    One of the pilot-machine interfaces (the forward viewing camera display) for an Unmanned Aerial Vehicle called the DROID (Dryden Remotely Operated Integrated Drone) will be analyzed for optimization. The goal is to create a visual display for the pilot that as closely resembles an out-the-window view as possible. There are currently no standard guidelines for designing pilot-machine interfaces for UAVs. Typically, UAV camera views have a narrow field, which limits the situational awareness (SA) of the pilot. Also, at this time, pilot-UAV interfaces often use displays that have a diagonal length of around 20". Using a small display may result in a distorted and disproportional view for UAV pilots. Making use of a larger display and a camera lens with a wider field of view may minimize the occurrences of pilot error associated with the inability to see "out the window" as in a manned airplane. It is predicted that the pilot will have a less distorted view of the DROID s surroundings, quicker response times and more stable vehicle control. If the experimental results validate this concept, other UAV pilot-machine interfaces will be improved with this design methodology.

  17. Moving Ahead With Eye Power

    NASA Technical Reports Server (NTRS)

    2002-01-01

    NASA's Jet Propulsion Laboratory's collaborated with LC Technologies, Inc., to improve LCT's Eyegaze Communication System, an eye tracker that enables people with severe cerebral palsy, muscular dystrophy, multiple sclerosis, strokes, brain injuries, spinal cord injuries, and ALS (amyotrophic lateral sclerosis) to communicate and control their environment using their eye movements. To operate the system, the user sits in front of the computer monitor while the camera focuses on one eye. By looking at control keys on the monitor for a fraction of a second, the user can 'talk' with speech synthesis, type, operate a telephone, access the Internet and e-mail, and run computer software. Nothing is attached to the user's head or body, and the improved size and portability allow the system to be mounted on a wheelchair. LCT and JPL are working on several other areas of improvement that have commercial add-on potential.

  18. The Opaque Projector: The Inverse of the Camera Obscura

    ERIC Educational Resources Information Center

    Greenslade, Thomas B., Jr.

    2011-01-01

    Many years ago I was running the standard laboratory experiment on thin lens optics. The source was the usual self illuminated object mounted on an optical bench, and a converging lens formed a real image on a screen. One of the students sitting near one wall of the darkened lab was having some trouble with the idea of image formation. Her face…

  19. KSC-00pp1607

    NASA Image and Video Library

    2000-10-23

    In the Space Station Processing Facility, members of the STS-98 crew, sitting in front of the U.S. Lab, Destiny, listen to a trainer during Crew Equipment Interface Test (CEIT) activities. Seen, left to right, are Mission Specialist Thomas Jones, Pilot Mark Polansky and Mission Specialists Robert Curbeam and Marsha Ivins (with camera). The CEIT allows a crew to become familiar with equipment they will be handling during the mission. With launch scheduled for Jan. 18, 2001, the STS-98 mission will be transporting the Lab to the International Space Station with five system racks already installed inside of the module. After delivery of electronics in the lab, electrically powered attitude control for Control Moment Gyroscopes will be activated

  20. It's not the pixel count, you fool

    NASA Astrophysics Data System (ADS)

    Kriss, Michael A.

    2012-01-01

    The first thing a "marketing guy" asks the digital camera engineer is "how many pixels does it have, for we need as many mega pixels as possible since the other guys are killing us with their "umpteen" mega pixel pocket sized digital cameras. And so it goes until the pixels get smaller and smaller in order to inflate the pixel count in the never-ending pixel-wars. These small pixels just are not very good. The truth of the matter is that the most important feature of digital cameras in the last five years is the automatic motion control to stabilize the image on the sensor along with some very sophisticated image processing. All the rest has been hype and some "cool" design. What is the future for digital imaging and what will drive growth of camera sales (not counting the cell phone cameras which totally dominate the market in terms of camera sales) and more importantly after sales profits? Well sit in on the Dark Side of Color and find out what is being done to increase the after sales profits and don't be surprised if has been done long ago in some basement lab of a photographic company and of course, before its time.

  1. STS-98 crew members take part in CEIT

    NASA Technical Reports Server (NTRS)

    2000-01-01

    In the Space Station Processing Facility, members of the STS-98 crew, sitting in front of the U.S. Lab, Destiny, listen to a trainer during Crew Equipment Interface Test (CEIT) activities. Seen, left to right, are Mission Specialist Thomas Jones, Pilot Mark Polansky and Mission Specialists Robert Curbeam and Marsha Ivins (with camera). The CEIT allows a crew to become familiar with equipment they will be handling during the mission. With launch scheduled for Jan. 18, 2001, the STS-98 mission will be transporting the Lab to the International Space Station with five system racks already installed inside of the module. After delivery of electronics in the lab, electrically powered attitude control for Control Moment Gyroscopes will be activated.

  2. Jasmonic acid accumulation and systemic photosynthetic and electrical changes in locally burned wild type tomato, ABA-deficient sitiens mutants and sitiens pre-treated by ABA.

    PubMed

    Hlavinka, Jan; Nožková-Hlaváčková, Vladimíra; Floková, Kristýna; Novák, Ondřej; Nauš, Jan

    2012-05-01

    Burning the terminal leaflet of younger tomato (Lycopersicon esculentum Mill.) leaf caused local and systemic changes in the surface electrical potential (SEP) and gas exchange (GE) parameters. The local and systemic accumulation of endogenous abscisic acid (ABA) and jasmonic acid (JA) was measured 85 min after burning. The experiments were conducted with wild type (WT) plants, ABA-deficient mutant sitiens (SIT) and ABA pre-treated SIT plants (SITA). First changes in SEP were detected within 1.5 min after burning and were followed by a decrease in GE parameters within 3-6 min in WT, SIT and SITA plants. GE and SEP time courses of SIT were different and wave amplitudes of SEP of SIT were lower compared to WT and SITA. ABA content in WT and SITA control plants was similar and substantially higher compared to SIT, JA content was similar among WT, SIT and SITA. While changes in the ABA content in systemic leaves have not been recorded after burning, the systemic JA content was substantially increased in WT and more in SIT and SITA. The results suggest that ABA content governs the systemic reaction of GE and the SEP shape upon local burning. ABA, JA and SEP participate in triggering the GE reaction. The ABA shortage in the SIT in the reaction to burning is partly compensated by an enhanced JA accumulation. This JA compensation is maintained even in SIT endogenously supplied with ABA. A correlation between the systemic JA content and changes in GE parameters or SEP was not found. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  3. Spirit Scans Winter Haven

    NASA Technical Reports Server (NTRS)

    2006-01-01

    At least three different kinds of rocks await scientific analysis at the place where NASA's Mars Exploration Rover Spirit will likely spend several months of Martian winter. They are visible in this picture, which the panoramic camera on Spirit acquired during the rover's 809th sol, or Martian day, of exploring Mars (April 12, 2006). Paper-thin layers of light-toned, jagged-edged rocks protrude horizontally from beneath small sand drifts; a light gray rock with smooth, rounded edges sits atop the sand drifts; and several dark gray to black, angular rocks with vesicles (small holes) typical of hardened lava lie scattered across the sand.

    This view is an approximately true-color rendering that combines images taken through the panoramic camera's 753-nanometer, 535-nanometer, and 432-nanometer filters.

  4. Pre-Clinical and Clinical Evaluation of High Resolution, Mobile Gamma Camera and Positron Imaging Devices

    DTIC Science & Technology

    2007-11-01

    accuracy. FPGA ADC data acquisition is controlled by distributed Java -based software. Java -based server application sits on each of the acquisition...JNI ( Java Native Interface) is used to allow Java indirect control of the USB driver. Fig. 5. Photograph of mobile electronics rack...supplies with the monitor and keyboard. The server application on each of these machines is controlled by a remote client Java -based application

  5. Video Golf

    NASA Technical Reports Server (NTRS)

    1995-01-01

    George Nauck of ENCORE!!! invented and markets the Advanced Range Performance (ARPM) Video Golf System for measuring the result of a golf swing. After Nauck requested their assistance, Marshall Space Flight Center scientists suggested video and image processing/computing technology, and provided leads on commercial companies that dealt with the pertinent technologies. Nauck contracted with Applied Research Inc. to develop a prototype. The system employs an elevated camera, which sits behind the tee and follows the flight of the ball down range, catching the point of impact and subsequent roll. Instant replay of the video on a PC monitor at the tee allows measurement of the carry and roll. The unit measures distance and deviation from the target line, as well as distance from the target when one is selected. The information serves as an immediate basis for making adjustments or as a record of skill level progress for golfers.

  6. Weight-bearing asymmetries during Sit-To-Stand in patients with mild-to-moderate hip osteoarthritis.

    PubMed

    Eitzen, Ingrid; Fernandes, Linda; Nordsletten, Lars; Snyder-Mackler, Lynn; Risberg, May Arna

    2014-02-01

    The Sit-To-Stand (STS) transition is a mechanically demanding task that may pose particular challenges for individuals with lower limb osteoarthritis (OA). Biomechanical features of STS have been investigated in patients with OA, but not in patients with early stage hip OA. The purpose of this study was to explore inter-limb weight-bearing asymmetries (WBA) and selected kinematic and kinetic variables during STS in patients with mild-to-moderate hip OA compared with healthy controls. Twenty-one hip OA patients and 23 controls were included in the study. Sagittal and frontal plane kinematic and kinetic data were collected using an eight-camera motion analysis system synchronized with two force plates embedded in the floor. There were no distinctive biomechanical alterations in sagittal or frontal plane kinematics or kinetics, movement time, or time to reach peak ground reaction force (GRF) in hip OA patients compared with controls. However, the hip OA patients revealed a distinct pattern of WBA compared with the controls, in unloading their involved limb by 18.4% at peak GRF. These findings indicate that patients with early stage hip OA are not yet forced into a stereotypical movement strategy for STS; however, the observed pattern of WBA requires clinical attention. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Raffaello Multi-Purpose Logistics Module (MPLM) in the Endeavour payload bay prior to docking

    NASA Image and Video Library

    2001-04-21

    ISS002-E-5815 (21 April 2001) --- The Raffaello Multi-Purpose Logistics Module (MPLM), built by the Italian Space Agency (ASI), sits in its berthed position in the cargo bay of the Space Shuttle Endeavour as the STS-100 crew eases the vehicle close to the International Space Station (ISS) for docking. The image was recorded with a digital still camera by one of the Expedition Two crew members aboard the Station.

  8. Sitting Posture Monitoring System Based on a Low-Cost Load Cell Using Machine Learning

    PubMed Central

    Roh, Jongryun; Park, Hyeong-jun; Lee, Kwang Jin; Hyeong, Joonho; Kim, Sayup

    2018-01-01

    Sitting posture monitoring systems (SPMSs) help assess the posture of a seated person in real-time and improve sitting posture. To date, SPMS studies reported have required many sensors mounted on the backrest plate and seat plate of a chair. The present study, therefore, developed a system that measures a total of six sitting postures including the posture that applied a load to the backrest plate, with four load cells mounted only on the seat plate. Various machine learning algorithms were applied to the body weight ratio measured by the developed SPMS to identify the method that most accurately classified the actual sitting posture of the seated person. After classifying the sitting postures using several classifiers, average and maximum classification rates of 97.20% and 97.94%, respectively, were obtained from nine subjects with a support vector machine using the radial basis function kernel; the results obtained by this classifier showed a statistically significant difference from the results of multiple classifications using other classifiers. The proposed SPMS was able to classify six sitting postures including the posture with loading on the backrest and showed the possibility of classifying the sitting posture even though the number of sensors is reduced. PMID:29329261

  9. Spirit Beholds Bumpy Boulder

    NASA Technical Reports Server (NTRS)

    2006-01-01

    As NASA's Mars Exploration Rover Spirit began collecting images for a 360-degree panorama of new terrain, the rover captured this view of a dark boulder with an interesting surface texture. The boulder sits about 40 centimeters (16 inches) tall on Martian sand about 5 meters (16 feet) away from Spirit. It is one of many dark, volcanic rock fragments -- many pocked with rounded holes called vesicles -- littering the slope of 'Low Ridge.' The rock surface facing the rover is similar in appearance to the surface texture on the outside of lava flows on Earth.

    Spirit took this approximately true-color image with the panoramic camera on the rover's 810th sol, or Martian day, of exploring Mars (April 13, 2006), using the camera's 753-nanometer, 535-nanometer, and 432-nanometer filters.

  10. Spirit Scans Winter Haven (False Color)

    NASA Technical Reports Server (NTRS)

    2006-01-01

    At least three different kinds of rocks await scientific analysis at the place where NASA's Mars Exploration Rover Spirit will likely spend several months of Martian winter. They are visible in this picture, which the panoramic camera on Spirit acquired during the rover's 809th sol, or Martian day, of exploring Mars (April 12, 2006). Paper-thin layers of light-toned, jagged-edged rocks protrude horizontally from beneath small sand drifts; a light gray rock with smooth, rounded edges sits atop the sand drifts; and several dark gray to black, angular rocks with vesicles (small holes) typical of hardened lava lie scattered across the sand.

    This view is a false-color rendering that combines images taken through the panoramic camera's 753-nanometer, 535-nanometer, and 432-nanometer filters.

  11. Laser guide star pointing camera for ESO LGS Facilities

    NASA Astrophysics Data System (ADS)

    Bonaccini Calia, D.; Centrone, M.; Pedichini, F.; Ricciardi, A.; Cerruto, A.; Ambrosino, F.

    2014-08-01

    Every observatory using LGS-AO routinely has the experience of the long time needed to bring and acquire the laser guide star in the wavefront sensor field of view. This is mostly due to the difficulty of creating LGS pointing models, because of the opto-mechanical flexures and hysteresis in the launch and receiver telescope structures. The launch telescopes are normally sitting on the mechanical structure of the larger receiver telescope. The LGS acquisition time is even longer in case of multiple LGS systems. In this framework the optimization of the LGS systems absolute pointing accuracy is relevant to boost the time efficiency of both science and technical observations. In this paper we show the rationale, the design and the feasibility tests of a LGS Pointing Camera (LPC), which has been conceived for the VLT Adaptive Optics Facility 4LGSF project. The LPC would assist in pointing the four LGS, while the VLT is doing the initial active optics cycles to adjust its own optics on a natural star target, after a preset. The LPC allows minimizing the needed accuracy for LGS pointing model calibrations, while allowing to reach sub-arcsec LGS absolute pointing accuracy. This considerably reduces the LGS acquisition time and observations operation overheads. The LPC is a smart CCD camera, fed by a 150mm diameter aperture of a Maksutov telescope, mounted on the top ring of the VLT UT4, running Linux and acting as server for the client 4LGSF. The smart camera is able to recognize within few seconds the sky field using astrometric software, determining the stars and the LGS absolute positions. Upon request it returns the offsets to give to the LGS, to position them at the required sky coordinates. As byproduct goal, once calibrated the LPC can calculate upon request for each LGS, its return flux, its fwhm and the uplink beam scattering levels.

  12. Downward Slope

    NASA Technical Reports Server (NTRS)

    2004-01-01

    This false-color image from NASA's Mars Exploration Rover Opportunity panoramic camera shows a downward view from the rover as it sits at the edge of 'Endurance' crater. The gradual, 'blueberry'-strewn slope before the rover contains an exposed dark layer of rock that wraps around the upper section of the crater. Scientists suspect that this rock layer will provide clues about Mars' distant past. This mosaic image comprises images taken from 10 rover positions using 750, 530 and 430 nanometer filters, acquired on sol 131 (June 6, 2004).

  13. The Application of Particle Image Velocimetry (PIV) in a Short Duration Transonic Annular Turbine Cascade

    DTIC Science & Technology

    1991-03-01

    series of experiments have been performed to create a plane of light with a ruby pulse laser and photograph demonstrate the application of Particle...using a SIT 1. INTRODUCTION (silicon intensified tube) camera developed 6y Wernet at NASA Lewis (1989). Optical diagnostics have now become essential...lens for the PIV tests. Fig 2 shows a photograph of the As a result of this the potential sensitivity of the technique has nozzle guide vanes

  14. Validation of Attitude and Heading Reference System and Microsoft Kinect for Continuous Measurement of Cervical Range of Motion Compared to the Optical Motion Capture System.

    PubMed

    Song, Young Seop; Yang, Kyung Yong; Youn, Kibum; Yoon, Chiyul; Yeom, Jiwoon; Hwang, Hyeoncheol; Lee, Jehee; Kim, Keewon

    2016-08-01

    To compare optical motion capture system (MoCap), attitude and heading reference system (AHRS) sensor, and Microsoft Kinect for the continuous measurement of cervical range of motion (ROM). Fifteen healthy adult subjects were asked to sit in front of the Kinect camera with optical markers and AHRS sensors attached to the body in a room equipped with optical motion capture camera. Subjects were instructed to independently perform axial rotation followed by flexion/extension and lateral bending. Each movement was repeated 5 times while being measured simultaneously with 3 devices. Using the MoCap system as the gold standard, the validity of AHRS and Kinect for measurement of cervical ROM was assessed by calculating correlation coefficient and Bland-Altman plot with 95% limits of agreement (LoA). MoCap and ARHS showed fair agreement (95% LoA<10°), while MoCap and Kinect showed less favorable agreement (95% LoA>10°) for measuring ROM in all directions. Intraclass correlation coefficient (ICC) values between MoCap and AHRS in -40° to 40° range were excellent for flexion/extension and lateral bending (ICC>0.9). ICC values were also fair for axial rotation (ICC>0.8). ICC values between MoCap and Kinect system in -40° to 40° range were fair for all motions. Our study showed feasibility of using AHRS to measure cervical ROM during continuous motion with an acceptable range of error. AHRS and Kinect system can also be used for continuous monitoring of flexion/extension and lateral bending in ordinary range.

  15. Spirit Beholds Bumpy Boulder (False Color)

    NASA Technical Reports Server (NTRS)

    2006-01-01

    As NASA's Mars Exploration Rover Spirit began collecting images for a 360-degree panorama of new terrain, the rover captured this view of a dark boulder with an interesting surface texture. The boulder sits about 40 centimeters (16 inches) tall on Martian sand about 5 meters (16 feet) away from Spirit. It is one of many dark, volcanic rock fragments -- many pocked with rounded holes called vesicles -- littering the slope of 'Low Ridge.' The rock surface facing the rover is similar in appearance to the surface texture on the outside of lava flows on Earth.

    Spirit took this false-color image with the panoramic camera on the rover's 810th sol, or Martian day, of exploring Mars (April 13, 2006). This image is a false-color rendering using camera's 753-nanometer, 535-nanometer, and 432-nanometer filters.

  16. 'Endurance' Untouched

    NASA Technical Reports Server (NTRS)

    2004-01-01

    This navigation camera mosaic, created from images taken by NASA's Mars Exploration Rover Opportunity on sols 115 and 116 (May 21 and 22, 2004) provides a dramatic view of 'Endurance Crater.' The rover engineering team carefully plotted the safest path into the football field-sized crater, eventually easing the rover down the slopes around sol 130 (June 12, 2004). To the upper left of the crater sits the rover's protective heatshield, which sheltered Opportunity as it passed through the martian atmosphere. The 360-degree view is presented in a cylindrical projection, with geometric and radiometric seam correction.

  17. 'Endurance' Untouched (vertical)

    NASA Technical Reports Server (NTRS)

    2004-01-01

    This navigation camera mosaic, created from images taken by NASA's Mars Exploration Rover Opportunity on sols 115 and 116 (May 21 and 22, 2004) provides a dramatic view of 'Endurance Crater.' The rover engineering team carefully plotted the safest path into the football field-sized crater, eventually easing the rover down the slopes around sol 130 (June 12, 2004). To the upper left of the crater sits the rover's protective heatshield, which sheltered Opportunity as it passed through the martian atmosphere. The 360-degree view is presented in a vertical projection, with geometric and radiometric seam correction.

  18. 'Endurance' Untouched (polar)

    NASA Technical Reports Server (NTRS)

    2004-01-01

    This navigation camera mosaic, created from images taken by NASA's Mars Exploration Rover Opportunity on sols 115 and 116 (May 21 and 22, 2004) provides a dramatic view of 'Endurance Crater.' The rover engineering team carefully plotted the safest path into the football field-sized crater, eventually easing the rover down the slopes around sol 130 (June 12, 2004). To the upper left of the crater sits the rover's protective heatshield, which sheltered Opportunity as it passed through the martian atmosphere. The 360-degree view is presented in a polar projection, with geometric and radiometric seam correction.

  19. Opportunity's Travels

    NASA Technical Reports Server (NTRS)

    2004-01-01

    This overview map made from Mars Orbiter camera images illustrates the path that the Mars Exploration Rover Opportunity has taken from its first sol on the red planet through its 87th sol. After thoroughly examining its 'Eagle Crater' landing-site, the rover moved onto the plains of Meridiani Planum, stopping to examine a curious trough and a target within it called 'Anatolia.' Following that, Opportunity approached and remotely studied the rocky dish called 'Fram Crater.' As of its 91st sol (April 26, 2004), the rover sits 160 meters (about 525 feet) from the rim of 'Endurance Crater.'

  20. Rover Tracks

    NASA Image and Video Library

    1997-07-07

    Tracks made by the Sojourner rover are visible in this image, taken by one of the cameras aboard Sojourner on Sol 3. The tracks represent the rover maneuvering towards the rock dubbed "Barnacle Bill." The rover, having exited the lander via the rear ramp, first traveled towards the right portion of the image, and then moved forward towards the left where Barnacle Bill sits. The fact that the rover was making defined tracks indicates that the soil is made up of particles on a micron scale. http://photojournal.jpl.nasa.gov/catalog/PIA00633

  1. STS-98 crewmembers prepare for rendezvous and docking with ISS

    NASA Image and Video Library

    2001-02-09

    STS98-E-5030 (9 February 2001) --- Three members of the STS-98 crew prepare for rendezvous with the International Space Station (ISS). Astronaut Thomas D. Jones (right), mission specialist, temporarily mans the pilot's station on the flight deck of the Space Shuttle Atlantis. Astronaut Mark L. Polansky, left, sits at the commander's station for this maneuver. At lower left is Astronaut Robert L. Curbeam, mission specialist. Astronaut Kenneth D. Cockrell, mission commander, is just out of frame at right. The photograph was recorded with a digital still camera.

  2. KSC-07pd2215

    NASA Image and Video Library

    2007-08-04

    KENNEDY SPACE CENTER, FLA. - In the Orbiter Processing Facility bay 3, STS-120 Commander Pamela A. Melroy sits in the orbiter Discovery to inspect the cockpit windows. The STS-120 crew is at Kennedy for a crew equipment interface test, or CEIT, which includes harness training, inspection of the thermal protection system and camera operation for planned extravehicular activities, or EVAs. The STS-120 mission will deliver the Harmony module, christened after a school contest, which will provide attachment points for European and Japanese laboratory modules on the International Space Station. Known in technical circles as Node 2, it is similar to the six-sided Unity module that links the U.S. and Russian sections of the station. Built in Italy for the United States, Harmony will be the first new U.S. pressurized component to be added. The STS-120 mission is targeted to launch on Oct. 20. Photo credit: NASA/George Shelton

  3. KSC-07pd2216

    NASA Image and Video Library

    2007-08-04

    KENNEDY SPACE CENTER, FLA. - In the Orbiter Processing Facility bay 3,STS-120 Commander Pamela A. Melroy sits in the orbiter Discovery to inspect the cockpit windows. The STS-120 crew is at Kennedy for a crew equipment interface test, or CEIT, which includes harness training, inspection of the thermal protection system and camera operation for planned extravehicular activities, or EVAs. The STS-120 mission will deliver the Harmony module, christened after a school contest, which will provide attachment points for European and Japanese laboratory modules on the International Space Station. Known in technical circles as Node 2, it is similar to the six-sided Unity module that links the U.S. and Russian sections of the station. Built in Italy for the United States, Harmony will be the first new U.S. pressurized component to be added. The STS-120 mission is targeted to launch on Oct. 20. Photo credit: NASA/George Shelton

  4. Status of MUSIC, the MUltiwavelength Sub/millimeter Inductance Camera

    NASA Astrophysics Data System (ADS)

    Golwala, Sunil R.; Bockstiegel, Clint; Brugger, Spencer; Czakon, Nicole G.; Day, Peter K.; Downes, Thomas P.; Duan, Ran; Gao, Jiansong; Gill, Amandeep K.; Glenn, Jason; Hollister, Matthew I.; LeDuc, Henry G.; Maloney, Philip R.; Mazin, Benjamin A.; McHugh, Sean G.; Miller, David; Noroozian, Omid; Nguyen, Hien T.; Sayers, Jack; Schlaerth, James A.; Siegel, Seth; Vayonakis, Anastasios K.; Wilson, Philip R.; Zmuidzinas, Jonas

    2012-09-01

    We present the status of MUSIC, the MUltiwavelength Sub/millimeter Inductance Camera, a new instrument for the Caltech Submillimeter Observatory. MUSIC is designed to have a 14', diffraction-limited field-of-view instrumented with 2304 detectors in 576 spatial pixels and four spectral bands at 0.87, 1.04, 1.33, and 1.98 mm. MUSIC will be used to study dusty star-forming galaxies, galaxy clusters via the Sunyaev-Zeldovich effect, and star formation in our own and nearby galaxies. MUSIC uses broadband superconducting phased-array slot-dipole antennas to form beams, lumpedelement on-chip bandpass filters to define spectral bands, and microwave kinetic inductance detectors to sense incoming light. The focal plane is fabricated in 8 tiles consisting of 72 spatial pixels each. It is coupled to the telescope via an ambient-temperature ellipsoidal mirror and a cold reimaging lens. A cold Lyot stop sits at the image of the primary mirror formed by the ellipsoidal mirror. Dielectric and metal-mesh filters are used to block thermal infrared and out-ofband radiation. The instrument uses a pulse tube cooler and 3He/ 3He/4He closed-cycle cooler to cool the focal plane to below 250 mK. A multilayer shield attenuates Earth's magnetic field. Each focal plane tile is read out by a single pair of coaxes and a HEMT amplifier. The readout system consists of 16 copies of custom-designed ADC/DAC and IF boards coupled to the CASPER ROACH platform. We focus on recent updates on the instrument design and results from the commissioning of the full camera in 2012.

  5. Comparison of Sedentary Behaviors in Office Workers Using Sit-Stand Tables With and Without Semiautomated Position Changes.

    PubMed

    Barbieri, Dechristian França; Srinivasan, Divya; Mathiassen, Svend Erik; Oliveira, Ana Beatriz

    2017-08-01

    We compared usage patterns of two different electronically controlled sit-stand tables during a 2-month intervention period among office workers. Office workers spend most of their working time sitting, which is likely detrimental to health. Although the introduction of sit-stand tables has been suggested as an effective intervention to decrease sitting time, limited evidence is available on usage patterns of sit-stand tables and whether patterns are influenced by table configuration. Twelve workers were provided with standard sit-stand tables (nonautomated table group) and 12 with semiautomated sit-stand tables programmed to change table position according to a preset pattern, if the user agreed to the system-generated prompt (semiautomated table group). Table position was monitored continuously for 2 months after introducing the tables, as a proxy for sit-stand behavior. On average, the table was in a "sit" position for 85% of the workday in both groups; this percentage did not change significantly during the 2-month period. Switches in table position from sit to stand were, however, more frequent in the semiautomated table group than in the nonautomated table group (0.65 vs. 0.29 hr -1 ; p = .001). Introducing a semiautomated sit-stand table appeared to be an attractive alternative to a standard sit-stand table, because it led to more posture variation. A semiautomated sit-stand table may effectively contribute to making postures more variable among office workers and thus aid in alleviating negative health effects of extensive sitting.

  6. IDEEA activity monitor: validity of activity recognition for lying, reclining, sitting and standing.

    PubMed

    Jiang, Yuyu; Larson, Janet L

    2013-03-01

    Recent evidence demonstrates the independent negative effects of sedentary behavior on health, but there are few objective measures of sedentary behavior. Most instruments measure physical activity and are not validated as measures of sedentary behavior. The purpose of this study was to evaluate the validity of the IDEEA system's measures of sedentary and low-intensity physical activities: lying, reclining, sitting and standing. Thirty subjects, 14 men and 16 women, aged 23 to 77 years, body mass index (BMI) between 18 to 34 kg/m(2), participated in the study. IDEEA measures were compared to direct observation for 27 activities: 10 lying in bed, 3 lying on a sofa, 1 reclining in a lawn chair, 10 sitting and 3 standing. Two measures are reported, the percentage of activities accurately identified and the percentage of monitored time that was accurately labeled by the IDEEA system for all subjects. A total of 91.6% of all observed activities were accurately identified and 92.4% of the total monitored time was accurately labeled. The IDEEA system did not accurately differentiate between lying and reclining so the two activities were combined for calculating accuracy. Using this approach the IDEEA system accurately identified 96% of sitting activities for a total of 97% of the monitored sitting time, 99% and 99% for standing, 87% and 88% for lying in bed, 87% and 88% for lying on the sofa, and 83% and 83% for reclining on a lawn chair. We conclude that the IDEEA system accurately recognizes sitting and standing positions, but it is less accurate in identifying lying and reclining positions. We recommend combining the lying and reclining activities to improve accuracy. The IDEEA system enables researchers to monitor lying, reclining, sitting and standing with a reasonable level of accuracy and has the potential to advance the science of sedentary behaviors and low-intensity physical activities.

  7. Comparative analysis of respiratory systems compliance in three different positioning (lateral, dorsal and sitting) in patients in prolonged invasive mechanical ventilation.

    PubMed

    Porto, Elias Ferreira; Castro, Antonio Adolfo Matos de; Leite, José Renato de Oliveira; Miranda, Saul Vitoriano; Lancauth, Auristela; Kumpel, Claudia

    2008-09-01

    This study is justified by the fact that in clinical practice, changes occur in patient's positioning in the bed during hospitalization in intensive care unity, it's necessary better understanding about possible adverse effects that such changes might cause mainly on the respiratory system condition. The objective this study was to evaluate if the patients positioning in bed can to alter the pulmonary complacency. All included patients were submitted to mechanical ventilation and were sedated and curarized respiratory system compliance was assessed in three different positioning: lateral, dorsal and sitting. After an alveolar recruitment maneuver, patients were placed to a position throughout two hours, and in the last five minutes the data was collected from the mechanical ventilator display. twenty eight patients were prospectively assessed. Values of respiratory system compliance in the lateral position were 37,07 ± 12,9 in the dorsal were 39,2 ± 10,5 and in the sitting 43,4 ± 9,6 mL/cmH2O. There were a statistical difference when we compared to the sitting and dorsal with lateral positioning for respiratory system compliance (p = 0.0052) and tidal volume (p < 0.001). There was a negative correlation between mean values of positive end expiratory pressure a respiratory system compliance (r = 0.59, p = 0.002). The FIO2 administered was 0.6 for the lateral positioning and 0.5 for the dorsal and sitting positioning (p = 0.049). That body positioning in patients restrained to a bed and submitted to invasive mechanical ventilation leads to pulmonary compliance, tidal volume and SpO2 oscillations. In the sitting position the pulmonary compliance is higher than in others positions.

  8. Compound Danshen injection improves endotoxin-induced microcirculatory disturbance in rat mesentery

    PubMed Central

    Han, Jing-Yan; Horie, Yoshinori; Miura, Soichiro; Akiba, Yasutada; Guo, Jun; Li, Dan; Fan, Jing-Yu; Liu, Yu-Ying; Hu, Bai-He; An, Li-Hua; Chang, Xin; Xu, Man; Guo, De-An; Sun, Kai; Yang, Ji-Ying; Fang, Shu-Ping; Xian, Ming-Ji; Kizaki, Masahiro; Nagata, Hiroshi; Hibi, Toshifumi

    2007-01-01

    AIM: To investigate the effect of compound Danshen injection on lipopolysaccharide (LPS)-induced rat mesenteric microcirculatory dysfunctions and the underlying possible mechanism by an inverted intravital microscope and high-speed video camera system. METHODS: LPS was continuously infused through the jugular artery of male Wistar rats at the dose of 2 mg/kg per hour. Changes in mesenteric microcirculation, such as diameters of arterioles and venules, velocity of RBCs in venules, leukocyte rolling, adhesion and emigration, free radicals released from post-capillary venules, FITC-albumin leakage and mast cell degranulation, were observed through an inverted intravital microscope assisted with CCD camera and SIT camera. Meanwhile, the expression of adhesion molecules CD11b/CD18 and the production of free radical in neutrophils, and the expression of intercellular adhesion molecule 1 (ICAM-1) in human umbilical vein endothelial cells (HUVECs) were quantified by flow cytometry (FACS) in vitro. RESULTS: The continuous infusion with LPS resulted in a number of responses in microcirculation, including a significant increase in the positive region of venule stained with Monastral blue B, rolling and adhesion of leukocytes, production of oxygen radical in venular wall, albumin efflux and enhanced mast cell degranulation in vivo, all of which, except for the leukocyte rolling, were attenuated by the treatment with compound Danshen injection. Experiments performed in vitro further revealed that the expression of CD11b/CD18 and the production of oxygen free radical in neutrophils, and the expression of ICAM-1 in HUVECs were increased by exposure to LPS, and they were attenuated by compound Danshen injection. CONCLUSION: These results suggest that compound Danshen injection is an efficient drug with multi-targeting potential for improving the microcirculatory disturbance. PMID:17659708

  9. Compound Danshen injection improves endotoxin-induced microcirculatory disturbance in rat mesentery.

    PubMed

    Han, Jing-Yan; Horie, Yoshinori; Miura, Soichiro; Akiba, Yasutada; Guo, Jun; Li, Dan; Fan, Jing-Yu; Liu, Yu-Ying; Hu, Bai-He; An, Li-Hua; Chang, Xin; Xu, Man; Guo, De-An; Sun, Kai; Yang, Ji-Ying; Fang, Shu-Ping; Xian, Ming-Ji; Kizaki, Masahiro; Nagata, Hiroshi; Hibi, Toshifumi

    2007-07-14

    To investigate the effect of compound Danshen injection on lipopolysaccharide (LPS)-induced rat mesenteric microcirculatory dysfunctions and the underlying possible mechanism by an inverted intravital microscope and high-speed video camera system. LPS was continuously infused through the jugular artery of male Wistar rats at the dose of 2 mg/kg per hour. Changes in mesenteric microcirculation, such as diameters of arterioles and venules, velocity of RBCs in venules, leukocyte rolling, adhesion and emigration, free radicals released from post-capillary venules, FITC-albumin leakage and mast cell degranulation, were observed through an inverted intravital microscope assisted with CCD camera and SIT camera. Meanwhile, the expression of adhesion molecules CD11b/CD18 and the production of free radical in neutrophils, and the expression of intercellular adhesion molecule 1 (ICAM-1) in human umbilical vein endothelial cells (HUVECs) were quantified by flow cytometry (FACS) in vitro. The continuous infusion with LPS resulted in a number of responses in microcirculation, including a significant increase in the positive region of venule stained with Monastral blue B, rolling and adhesion of leukocytes, production of oxygen radical in venular wall, albumin efflux and enhanced mast cell degranulation in vivo, all of which, except for the leukocyte rolling, were attenuated by the treatment with compound Danshen injection. Experiments performed in vitro further revealed that the expression of CD11b/CD18 and the production of oxygen free radical in neutrophils, and the expression of ICAM-1 in HUVECs were increased by exposure to LPS, and they were attenuated by compound Danshen injection. These results suggest that compound Danshen injection is an efficient drug with multi-targeting potential for improving the microcirculatory disturbance.

  10. Hidden marker position estimation during sit-to-stand with walker.

    PubMed

    Yoon, Sang Ho; Jun, Hong Gul; Dan, Byung Ju; Jo, Byeong Rim; Min, Byung Hoon

    2012-01-01

    Motion capture analysis of sit-to-stand task with assistive device is hard to achieve due to obstruction on reflective makers. Previously developed robotic system, Smart Mobile Walker, is used as an assistive device to perform motion capture analysis in sit-to-stand task. All lower limb markers except hip markers are invisible through whole session. The link-segment and regression method is applied to estimate the marker position during sit-to-stand. Applying a new method, the lost marker positions are restored and the biomechanical evaluation of the sit-to-stand movement with a Smart Mobile Walker could be carried out. The accuracy of the marker position estimation is verified with normal sit-to-stand data from more than 30 clinical trials. Moreover, further research on improving the link segment and regression method is addressed.

  11. A Trunk Support System to Identify Posture Control Mechanisms in Populations Lacking Independent Sitting

    PubMed Central

    Goodworth, Adam D.; Wu, Yen-Hsun; Felmlee, Duffy; Dunklebarger, Ellis; Saavedra, Sandra

    2016-01-01

    Populations with moderate-to-severe motor control impairments often exhibit degraded trunk control and/or lack the ability to sit unassisted. These populations need more research, yet their underdeveloped trunk control complicates identification of neural mechanisms behind their movements. The purpose of this study was to overcome this barrier by developing the first multi-articulated trunk support system to identify visual, vestibular, and proprioception contributions to posture in populations lacking independent sitting. The system provided external stability at a user-specific level on the trunk, so that body segments above the level of support required active posture control. The system included a tilting surface (controlled via servomotor) as a stimulus to investigate sensory contributions to postural responses. Frequency response and coherence functions between the surface tilt and trunk support were used to characterize system dynamics and indicated that surface tilts were accurately transmitted up to 5Hz. Feasibility of collecting kinematic data in participants lacking independent sitting was demonstrated in two populations: two typically developing infants, ~2-8 months, in a longitudinal study (8 sessions each) and four children with moderate-to-severe cerebral palsy (GMFCS III-V). Adaptability in the system was assessed by testing 16 adults (ages 18-63). Kinematic responses to continuous pseudorandom surface tilts were evaluated across 0.046–2Hz and qualitative feedback indicated that the trunk support and stimulus were comfortable for all subjects. Concepts underlying the system enable both research for, and rehabilitation in, populations lacking independent sitting. PMID:27046877

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loh, Yen Lee; Randeria, Mohit; Trivedi, Nandini

    The direct transition from an insulator to a superconductor (SC) in Fermi systems is a problem of long-standing interest, which necessarily goes beyond the standard BCS paradigm of superconductivity as a Fermi surface instability. We introduce here a simple, translationally invariant lattice fermion model that undergoes a SC-insulator transition (SIT) and elucidate its properties using analytical methods and quantum Monte Carlo simulations. We show that there is a fermionic band insulator to bosonic insulator crossover in the insulating phase and a BCS-to-BEC crossover in the SC. The SIT is always found to be from a bosonic insulator to a BEC-likemore » SC, with an energy gap for fermions that remains finite across the SIT. Hence, the energy scales that go critical at the SIT are the gap to pair excitations in the insulator and the superfluid stiffness in the SC. In addition to giving insight into important questions about the SIT in solid-state systems, our model should be experimentally realizable using ultracold fermions in optical lattices.« less

  13. Superconductor-insulator transition and Fermi-Bose crossovers

    DOE PAGES

    Loh, Yen Lee; Randeria, Mohit; Trivedi, Nandini; ...

    2016-05-31

    The direct transition from an insulator to a superconductor (SC) in Fermi systems is a problem of long-standing interest, which necessarily goes beyond the standard BCS paradigm of superconductivity as a Fermi surface instability. We introduce here a simple, translationally invariant lattice fermion model that undergoes a SC-insulator transition (SIT) and elucidate its properties using analytical methods and quantum Monte Carlo simulations. We show that there is a fermionic band insulator to bosonic insulator crossover in the insulating phase and a BCS-to-BEC crossover in the SC. The SIT is always found to be from a bosonic insulator to a BEC-likemore » SC, with an energy gap for fermions that remains finite across the SIT. Hence, the energy scales that go critical at the SIT are the gap to pair excitations in the insulator and the superfluid stiffness in the SC. In addition to giving insight into important questions about the SIT in solid-state systems, our model should be experimentally realizable using ultracold fermions in optical lattices.« less

  14. Comparisons of musculoskeletal complaints and data entry between a sitting and a sit-stand workstation paradigm.

    PubMed

    Husemann, Britta; Von Mach, Carolin Yvonne; Borsotto, Daniel; Zepf, Kirsten Isabel; Scharnbacher, Jutta

    2009-06-01

    Seated working positions are often regarded as a cause for discomfort in the musculoskeletal system. Performing work in different working positions--that is, alternating between sitting and standing (sit-stand workstation paradigm)--could help reduce physical complaints. The questions were whether performing office work partly in a standing position leads to reduced complaints and whether standing would change the efficiency of data entry office work. We investigated the effect of a sit-stand workstation paradigmd during experimental data entry office work on physical and psychological complaints and data entry efficiency by conducting a randomized controlled trial with 60 male participants ages 18 to 35 years. In this experiment, musculoskeletal complaints were reduced by a sit-stand workstation paradigm. A trend could be identified indicating a small but nonsignificant loss of efficiency in data entry while standing. A sit-stand workstation paradigm reduces musculoskeletal complaints without considerably affecting data entry efficiency under the presented study conditions (young male participants, short duration, fixed and controlled sit-stand workstation paradigm, simulated experimental working condition). According to the present data, implementing a sit-stand workstation paradigm can be an effective workplace health intervention to reduce musculoskeletal complaints. This experiment encourages further studies on the effectiveness of a sit-stand workstation paradigm. Experimental research and field studies that prove the reduction of complaints when introducing a sit-stand workstation paradigm in the workplace could be the basis for evidence-based recommendations regarding such interventions.

  15. Medium-range predictability of early summer sea ice thickness distribution in the East Siberian Sea based on the TOPAZ4 ice-ocean data assimilation system

    NASA Astrophysics Data System (ADS)

    Nakanowatari, Takuya; Inoue, Jun; Sato, Kazutoshi; Bertino, Laurent; Xie, Jiping; Matsueda, Mio; Yamagami, Akio; Sugimura, Takeshi; Yabuki, Hironori; Otsuka, Natsuhiko

    2018-06-01

    Accelerated retreat of Arctic Ocean summertime sea ice has focused attention on the potential use of the Northern Sea Route (NSR), for which sea ice thickness (SIT) information is crucial for safe maritime navigation. This study evaluated the medium-range (lead time below 10 days) forecast of SIT distribution in the East Siberian Sea (ESS) in early summer (June-July) based on the TOPAZ4 ice-ocean data assimilation system. A comparison of the operational model SIT data with reliable SIT estimates (hindcast, satellite and in situ data) showed that the TOPAZ4 reanalysis qualitatively reproduces the tongue-like distribution of SIT in ESS in early summer and the seasonal variations. Pattern correlation analysis of the SIT forecast data over 3 years (2014-2016) reveals that the early summer SIT distribution is accurately predicted for a lead time of up to 3 days, but that the prediction accuracy drops abruptly after the fourth day, which is related to a dynamical process controlled by synoptic-scale atmospheric fluctuations. For longer lead times ( > 4 days), the thermodynamic melting process takes over, which contributes to most of the remaining prediction accuracy. In July 2014, during which an ice-blocking incident occurred, relatively thick SIT ( ˜ 150 cm) was simulated over the ESS, which is consistent with the reduction in vessel speed. These results suggest that TOPAZ4 sea ice information has great potential for practical applications in summertime maritime navigation via the NSR.

  16. Acidalia and Chryse Plains, Mars

    NASA Image and Video Library

    2000-06-14

    Somewhere down there sits the Mars Pathfinder lander and Sojourner rover. This Mars Global Surveyor Mars Orbiter Camera view of the red planet shows the region that includes Ares Vallis and the Chryse Plains upon which both Mars Pathfinder and the Viking 1 landed in 1997 and 1976, respectively. Acidalia Planitia is the dark surface that dominates the center left. The Pathfinder site is immediately south of Acidalia, just left of center in this view. Also shown--the north polar cap is at the top, and Arabia Terra and Sinus Meridiani are to the right. The bluish-white features are clouds. This is a color composite of 9 red and 9 blue image strips taken by the Mars Global Surveyor Mars Orbiter Camera on 9 successive orbits from pole-to-pole during the calibration phase of the mission in March 1999. The color is computer-enhanced and is not shown as it would actually appear to the human eye. http://photojournal.jpl.nasa.gov/catalog/PIA02000

  17. [Cluster-immunotherapy in seasonal allergic rhinitis: safety aspects of induction therapy with depot allergoids (Purethal)].

    PubMed

    Hansen, I; Hörmann, K; Stuck, B A; Schneider-Gêne, S; Mösges, R; Klimek, L

    2003-08-01

    Specific immunotherapy (SIT) represents the only specific treatment that can be offered to allergic patients apart from allergen avoidance. SIT has been widely used in pollen allergic rhinitis. Clinical efficacy has been demonstrated in several controlled clinical trials and depends on the specific allergen the individual patient is sensitive to, the quality and total amount of allergen applied, and the SIT schedule. In classic SIT, gradually increasing dosages of the allergen extract are injected subcutaneously. Several dosage schedules for subcutaneous SIT can be applied. In Cluster-SIT, 2 - 3 injections per day of treatment are given once a week during induction treatment. In this study, we investigated 64 patients (33 female, 31 male) from 18 to 54 years (26.9 +/- 5.1 years) in terms of side-effects of Cluster-SIT during induction treatment. The total amount of enlarged local reactions (> grade 1) was n = 77 or 15.2 % of all injections. Of these, 68 (88 %) were classified as immediate reactions, 8 (11 %) were late phase reactions and 1 (1 %) was immediate as well as late phase reaction. Of all enlarged local reactions, 48 (62 %) were grade 1 reactions, 13 (17 %) were grade 2 reactions, 13 (17 %) were grade 3 reactions and 1 (1 %) was a grade 4 reaction. The total amount of systemic reactions was n = 22 or 4.3 % of all injections. Of these, 19 (86 %) were classified as immediate reactions, 3 (14 %) were delayed reactions. Of all systemic reactions, 18 (82 %) were grade 1 reactions and 4 (18 %) grade 2 reactions. Grade 3 or grade 4 reactions did not occur. There were no differences in gender or age regarding the occurrence of side effects (all p > 0.05). Frequency and severity of adverse side effects in Cluster-SIT correspond to those in other dosage schedules. On behalf of security aspects, Cluster-SIT could become an interesting alternative dosage schedule for dose increase during SIT. Furthermore, in Cluster-SIT with allergoids, induction treatment can be carried out in two treatment days of approximately 2.5 hours each.

  18. Hubble Finds a Lenticular Galaxy Standing Out in the Crowd

    NASA Image and Video Library

    2017-12-08

    A lone source shines out brightly from the dark expanse of deep space, glowing softly against a picturesque backdrop of distant stars and colorful galaxies. Captured by the NASA/ESA Hubble Space Telescope’s Advanced Camera for Surveys (ACS), this scene shows PGC 83677, a lenticular galaxy — a galaxy type that sits between the more familiar elliptical and spiral varieties. It reveals both the relatively calm outskirts and intriguing core of PGC 83677. Here, studies have uncovered signs of a monstrous black hole that is spewing out high-energy X-rays and ultraviolet light. Credit: NASA/ESA/Hubble; acknowledgements: Judy Schmidt (Geckzilla) NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  19. An inherent acceleratory effect of insulin on small intestinal transit and its pharmacological characterization in normal mice

    PubMed Central

    Peddyreddy, Murali Krishna Reddy; Dkhar, Steven Aibor; Ramaswamy, Subramanian; Naveen, Amrithraj Theophilus; Shewade, Deepak Gopal

    2006-01-01

    AIM: To study an inherent effect of insulin on small intestinal transit and to explore involvement of various systems/mechanisms in normal mice. METHODS: Insulin at the doses of 2 μU/kg, 2 mU/kg, 2 U/kg or vehicle was subcutaneously administered to four groups of overnight fasted normal male mice. Blood glucose (BG) levels were measured 2 min before insulin administration and 2 min before sacrificing the animals for the measurement of small intestinal transit (SIT). Charcoal meal was administered (0.3 mL) intragastrically 20 min after insulin administration and animals were sacrificed after 20 min and SIT was determined. For exploration of the various mechanisms involved in insulin-induced effect on SIT, the dose of insulin which can produce a significant acceleration of SIT without altering BG levels was determined. The following drugs, atropine (1 mg/kg), clonidine (0.1 mg/kg), ondansetron (1 mg/kg), naloxone (5 mg/kg), verapamil (8 mg/kg) and glibenclamide (10 mg/kg), were administered intravenously 10 min prior to the administration of insulin (2 μU/kg). RESULTS: The lower doses of insulin (2 μU/kg and 2 mU/kg) produced a significant acceleration of SIT from 52.0% to 70.7% and 73.5% without lowering blood glucose levels (P < 0.01), while the highest dose of insulin (2 U/kg) produced a fall in blood glucose levels which was also associated with significant acceleration of SIT (P < 0.01). After pretreatment of insulin (2 μU/kg) group with atropine, insulin could reverse 50% of the inhibition produced by atropine. In clonidine-pretreated group, insulin administration could reverse only 37% of the inhibition produced by clonidine and inhibition of SIT was significant compared with vehicle + insulin-treated group, i.e. from 74.7% to 27.7% (P < 0.01). In ondansetron-pretreated group, insulin administration could produce only mild acceleration of SIT (23.5%). In naloxone-pretreated group, insulin administration could significantly reverse the inhibition of SIT produced by naloxone when compared with naloxone per se group, i.e. from 32.3% to 53.9% (P < 0.01). In verapamil-pretreated group, insulin administration could only partially reverse the inhibition (65%). In glibenclamide-pretreated group, insulin administration produced further acceleration of SIT (12.2%). CONCLUSION: Insulin inherently possesses an acceleratory effect on SIT in normal mice. Adrenergic and cholinergic systems can play a significant role. Calcium channels and opioidergic system can play a supportive role; in addition, enhancement of endogenous insulin release can augment the effect of exogenously administered insulin on SIT. PMID:16688808

  20. Stereoscopic-3D display design: a new paradigm with Intel Adaptive Stable Image Technology [IA-SIT

    NASA Astrophysics Data System (ADS)

    Jain, Sunil

    2012-03-01

    Stereoscopic-3D (S3D) proliferation on personal computers (PC) is mired by several technical and business challenges: a) viewing discomfort due to cross-talk amongst stereo images; b) high system cost; and c) restricted content availability. Users expect S3D visual quality to be better than, or at least equal to, what they are used to enjoying on 2D in terms of resolution, pixel density, color, and interactivity. Intel Adaptive Stable Image Technology (IA-SIT) is a foundational technology, successfully developed to resolve S3D system design challenges and deliver high quality 3D visualization at PC price points. Optimizations in display driver, panel timing firmware, backlight hardware, eyewear optical stack, and synch mechanism combined can help accomplish this goal. Agnostic to refresh rate, IA-SIT will scale with shrinking of display transistors and improvements in liquid crystal and LED materials. Industry could profusely benefit from the following calls to action:- 1) Adopt 'IA-SIT S3D Mode' in panel specs (via VESA) to help panel makers monetize S3D; 2) Adopt 'IA-SIT Eyewear Universal Optical Stack' and algorithm (via CEA) to help PC peripheral makers develop stylish glasses; 3) Adopt 'IA-SIT Real Time Profile' for sub-100uS latency control (via BT Sig) to extend BT into S3D; and 4) Adopt 'IA-SIT Architecture' for Monitors and TVs to monetize via PC attach.

  1. Impaired Postural Control Reduces Sit-to-Stand-to-Sit Performance in Individuals with Chronic Obstructive Pulmonary Disease

    PubMed Central

    Janssens, Lotte; Brumagne, Simon; McConnell, Alison K.; Claeys, Kurt; Pijnenburg, Madelon; Goossens, Nina; Burtin, Chris; Janssens, Wim; Decramer, Marc; Troosters, Thierry

    2014-01-01

    Background Functional activities, such as the sit-to-stand-to-sit (STSTS) task, are often impaired in individuals with chronic obstructive pulmonary disease (COPD). The STSTS task places a high demand on the postural control system, which has been shown to be impaired in individuals with COPD. It remains unknown whether postural control deficits contribute to the decreased STSTS performance in individuals with COPD. Methods Center of pressure displacement was determined in 18 individuals with COPD and 18 age/gender-matched controls during five consecutive STSTS movements with vision occluded. The total duration, as well as the duration of each sit, sit-to-stand, stand and stand-to-sit phase was recorded. Results Individuals with COPD needed significantly more time to perform five consecutive STSTS movements compared to healthy controls (19±6 vs. 13±4 seconds, respectively; p = 0.001). The COPD group exhibited a significantly longer stand phase (p = 0.028) and stand-to-sit phase (p = 0.001) compared to the control group. In contrast, the duration of the sit phase (p = 0.766) and sit-to-stand phase (p = 0.999) was not different between groups. Conclusions Compared to healthy individuals, individuals with COPD needed significantly more time to complete those phases of the STSTS task that require the greatest postural control. These findings support the proposition that suboptimal postural control is an important contributor to the decreased STSTS performance in individuals with COPD. PMID:24533072

  2. Spirit's Travels

    NASA Technical Reports Server (NTRS)

    2004-01-01

    This overview map made from Mars Orbiter camera images illustrates the path that the Mars Exploration Rover Spirit has taken from its first sol on the red planet through its 107th sol. As of sol 112 (April 26, 2004), Spirit has passed 'Missoula' crater and sits approximately 1,900 meters (1.18 miles) away from its destination at the western base of the 'Columbia Hills.' While most of Spirit's journey has been over the very angular rocks that make up the ejecta fields surrounding 'Bonneville' crater, the rover's next 50 or so sols will be spent traversing over martian plains that are dominated by rounder, vesicle-filled rocks.

  3. Rogue waves and W-shaped solitons in the multiple self-induced transparency system.

    PubMed

    Wang, Xin; Liu, Chong; Wang, Lei

    2017-09-01

    We study localized nonlinear waves on a plane wave background in the multiple self-induced transparency (SIT) system, which describes an important enhancement of the amplification and control of optical waves compared to the single SIT system. A hierarchy of exact multiparametric rational solutions in a compact determinant representation is presented. We demonstrate that this family of solutions contain known rogue wave solutions and unusual W-shaped soliton solutions. State transitions between the fundamental rogue waves and W-shaped solitons as well as higher-order nonlinear superposition modes are revealed in the zero-frequency perturbation region by the suitable choice for the background wavenumber of the electric field component. Particularly, it is found that the multiple SIT system can admit both stationary and nonstationary W-shaped solitons in contrast to the stationary results in the single SIT system. Moreover, the W-shaped soliton complex which is formed by a certain number of fundamental W-shaped solitons with zero phase parameters and its decomposition mechanism in the case of the nonzero phase parameters are shown. Meanwhile, some important characteristics of the nonlinear waves including trajectories and spectrum are discussed through the numerical and analytical methods.

  4. An Evaluation of the Effectiveness of an Automated Observation and Feedback System on Safe Sitting Postures

    ERIC Educational Resources Information Center

    Yu, Eunjeong; Moon, Kwangsu; Oah, Shezeen; Lee, Yohaeng

    2013-01-01

    This study evaluated the effectiveness of an automated observation and feedback system in improving safe sitting postures. Participants were four office workers. The dependent variables were the percentages of time participants spent in five safe body positions during experimental sessions. We used a multiple-baseline design counterbalanced across…

  5. Infectious polymorphic toxins delivered by outer membrane exchange discriminate kin in myxobacteria.

    PubMed

    Vassallo, Christopher N; Cao, Pengbo; Conklin, Austin; Finkelstein, Hayley; Hayes, Christopher S; Wall, Daniel

    2017-08-18

    Myxobacteria are known for complex social behaviors including outer membrane exchange (OME), in which cells exchange large amounts of outer membrane lipids and proteins upon contact. The TraA cell surface receptor selects OME partners based on a variable domain. However, traA polymorphism alone is not sufficient to precisely discriminate kin. Here, we report a novel family of OME-delivered toxins that promote kin discrimination of OME partners. These SitA lipoprotein toxins are polymorphic and widespread in myxobacteria. Each sitA is associated with a cognate sitI immunity gene, and in some cases a sitB accessory gene. Remarkably, we show that SitA is transferred serially between target cells, allowing the toxins to move cell-to-cell like an infectious agent. Consequently, SitA toxins define strong identity barriers between strains and likely contribute to population structure, maintenance of cooperation, and strain diversification. Moreover, these results highlight the diversity of systems evolved to deliver toxins between bacteria.

  6. Agreement between Fiber Optic and Optoelectronic Systems for Quantifying Sagittal Plane Spinal Curvature in Sitting

    PubMed Central

    Cloud, Beth A.; Zhao, Kristin D.; Breighner, Ryan; Giambini, Hugo; An, Kai-Nan

    2014-01-01

    Spinal posture affects how individuals function from a manual wheelchair. There is a need to directly quantify spinal posture in this population to ultimately improve function. A fiber optic system, comprised of an attached series of sensors, is promising for measuring large regions of the spine in individuals sitting in a wheelchair. The purpose of this study was to determine the agreement between fiber optic and optoelectronic systems for measuring spinal curvature, and describe the range of sagittal plane spinal curvatures in natural sitting. Able-bodied adults (n=26, 13 male) participated. Each participant assumed three sitting postures: natural, slouched (accentuated kyphosis), and extension (accentuated lordosis) sitting. Fiber optic (ShapeTape) and optoelectronic (Optotrak) systems were applied to the skin over spinous processes from S1 to C7 and used to measure sagittal plane spinal curvature. Regions of kyphosis and lordosis were identified. A Cobb angle-like method was used to quantify lordosis and kyphosis. Generalized linear model and Bland-Altman analyses were used to assess agreement. A strong correlation exists between curvature values obtained with Optotrak and ShapeTape (R2=0.98). The mean difference between Optotrak and ShapeTape for kyphosis in natural, extension, and slouched postures was 4.30° (95%LOA: −3.43-12.04°), 3.64° (95%LOA: −1.07-8.36°), and 4.02° (95%LOA: −2.80-10.84°), respectively. The mean difference for lordosis, when present, in natural and extension postures is 2.86° (95%LOA: −1.18-6.90°) and 2.55° (95%LOA: −3.38-8.48°), respectively. In natural sitting, the mean±SD of kyphosis values was 35.07± 6.75°. Lordosis was detected in 8/26 participants: 11.72±7.32°. The fiber optic and optoelectronic systems demonstrate acceptable agreement for measuring sagittal plane thoracolumbar spinal curvature. PMID:24909579

  7. Exploring Science in the Studio: NSF-Funded Initiatives to Increase Scientific Literacy in Undergraduate Art and Design Students

    NASA Astrophysics Data System (ADS)

    Metzger, C. A.

    2015-12-01

    The project Exploring Science in the Studio at California College of the Arts (CCA), one of the oldest and most influential art and design schools in the country, pursues ways to enable undergraduate students to become scientifically literate problem-solvers in a variety of careers and to give content and context to their creative practices. The two main branches of this National Science Foundation-funded project are a series of courses called Science in the Studio (SitS) and the design of the Mobile Units for Science Exploration (MUSE) system, which allow instructors to bring science equipment directly into the studios. Ongoing since 2010, each fall semester a series of interdisciplinary SitS courses are offered in the college's principal areas of study (architecture, design, fine arts, humanities and sciences, and diversity studies) thematically linked by Earth and environmental science topics such as water, waste, and sustainability. Each course receives funding to embed guest scientists from other colleges and universities, industry, or agriculture directly into the studio courses. These scientists worked in tandem with the studio faculty and gave lectures, led field trips, conducted studio visits, and advised the students' creative endeavors, culminating in an annual SitS exhibition of student work. The MUSE system, of fillable carts and a storage and display unit, was designed by undergraduate students in a Furniture studio who explored, experimented, and researched various ways science materials and equipment are stored, collected, and displayed, for use in the current and future science and studio curricula at CCA. Sustainable practices and "smart design" underpinned all of the work completed in the studio. The materials selected for the new Science Collection at CCA include environmental monitoring equipment and test kits, a weather station, a stream table, a rock and fossil collection, and a vertebrate skull collection. The SitS courses and MUSE system provide two new, easily transferable models for scientific inquiry for other similarly sized colleges of art and design. Additionally, the MUSE provide a replicable model for bringing science instructional materials and equipment directly into classrooms at colleges that do not have stand-alone science departments or facilities.

  8. Prediction of orthostatic hypotension in multiple system atrophy and Parkinson disease

    PubMed Central

    Sun, Zhanfang; Jia, Dandan; Shi, Yuting; Hou, Xuan; Yang, Xiaosu; Guo, Jifeng; Li, Nan; Wang, Junling; Sun, Qiying; Zhang, Hainan; Lei, Lifang; Shen, Lu; Yan, Xinxiang; Xia, Kun; Jiang, Hong; Tang, Beisha

    2016-01-01

    Orthostatic hypotension (OH) is common in multiple system atrophy (MSA) and Parkinson disease (PD), generally assessed through a lying-to-standing orthostatic test. However, standing blood pressure may not be available due to orthostatic intolerance or immobilization for such patients. Systolic blood pressure (SBP) and diastolic blood pressure (DBP) were successively measured in supine, sitting, and standing positions in patients with MSA and PD. Receiver operating characteristic analysis was used to evaluate diagnostic performance of the drops of sitting SBP or DBP. OH and severe OH were respectively regarded as “gold standard”. The drops of SBP in standing position were associated with increased disease severity for MSA and correlated with age for PD. In MSA group, drops in sitting SBP ≥ 14 mmHg or DBP ≥ 6 mmHg had highest validity for prediction of OH, and drops in sitting SBP ≥ 18 mmHg or DBP ≥ 8 mmHg for severe OH. In PD group, drops in sitting SBP ≥ 10 mmHg or DBP ≥ 6 mmHg had highest validity for prediction of OH. The lying-to-sitting orthostatic test is an alternative method for detection of OH in MSA and PD, especially when standing BP could not be validly measured due to various reasons. PMID:26867507

  9. Electrophysiological assessment of piano players' back extensor muscles on a regular piano bench and chair with back rest.

    PubMed

    Honarmand, Kavan; Minaskanian, Rafael; Maboudi, Seyed Ebrahim; Oskouei, Ali E

    2018-01-01

    [Purpose] Sitting position is the dominant position for a professional pianist. There are many static and dynamic forces which affect musculoskeletal system during sitting. In prolonged sitting, these forces are harmful. The aim of this study was to compare pianists' back extensor muscles activity during playing piano while sitting on a regular piano bench and a chair with back rest. [Subjects and Methods] Ten professional piano players (mean age 25.4 ± 5.28, 60% male, 40% female) performed similar tasks for 5 hours in two sessions: one session sitting on a regular piano bench and the other sitting on a chair with back rest. In each session, muscular activity was assessed in 3 ways: 1) recording surface electromyography of the back-extensor muscles at the beginning and end of each session, 2) isometric back extension test, and 3) musculoskeletal discomfort questionnaire. [Results] There were significantly lesser muscular activity, more ability to perform isometric back extension and better personal comfort while sitting on a chair with back rest. [Conclusion] Decreased muscular activity and perhaps fatigue during prolonged piano playing on a chair with back rest may reduce acquired musculoskeletal disorders amongst professional pianists.

  10. Electrophysiological assessment of piano players’ back extensor muscles on a regular piano bench and chair with back rest

    PubMed Central

    Honarmand, Kavan; Minaskanian, Rafael; Maboudi, Seyed Ebrahim; Oskouei, Ali E.

    2018-01-01

    [Purpose] Sitting position is the dominant position for a professional pianist. There are many static and dynamic forces which affect musculoskeletal system during sitting. In prolonged sitting, these forces are harmful. The aim of this study was to compare pianists’ back extensor muscles activity during playing piano while sitting on a regular piano bench and a chair with back rest. [Subjects and Methods] Ten professional piano players (mean age 25.4 ± 5.28, 60% male, 40% female) performed similar tasks for 5 hours in two sessions: one session sitting on a regular piano bench and the other sitting on a chair with back rest. In each session, muscular activity was assessed in 3 ways: 1) recording surface electromyography of the back-extensor muscles at the beginning and end of each session, 2) isometric back extension test, and 3) musculoskeletal discomfort questionnaire. [Results] There were significantly lesser muscular activity, more ability to perform isometric back extension and better personal comfort while sitting on a chair with back rest. [Conclusion] Decreased muscular activity and perhaps fatigue during prolonged piano playing on a chair with back rest may reduce acquired musculoskeletal disorders amongst professional pianists. PMID:29410569

  11. A new method for sudden mechanical perturbation with axial load, to assess postural control in sitting and standing.

    PubMed

    Claus, Andrew P; Verrel, Julius; Pounds, Paul E I; Shaw, Renee C; Brady, Niamh; Chew, Min T; Dekkers, Thomas A; Hodges, Paul W

    2016-05-03

    Sudden application of load along a sagittal or coronal axis has been used to study trunk stiffness, but not axial (vertical) load. This study introduces a new method for sudden-release axial load perturbation. Prima facie validity was supported by comparison with standard mechanical systems. We report the response of the human body to axial perturbation in sitting and standing and within-day repeatability of measures. Load of 20% of body weight was released from light contact onto the shoulders of 22 healthy participants (10 males). Force input was measured via force transducers at shoulders, output via a force plate below the participant, and kinematics via 3-D motion capture. System identification was used to fit data from the time of load release to time of peak load-displacement, fitting with a 2nd-order mass-spring-damper system with a delay term. At peak load-displacement, the mean (SD) effective stiffness measured with this device for participants in sitting was 12.0(3.4)N/mm, and in standing was 13.3(4.2)N/mm. Peak force output exceeded input by 44.8 (10.0)% in sitting and by 30.4(7.9)% in standing. Intra-class correlation coefficients for within-day repeatability of axial stiffness were 0.58 (CI: -0.03 to 0.83) in sitting and 0.82(0.57-0.93) in standing. Despite greater degrees of freedom in standing than sitting, standing involved lesser time, downward displacement, peak output force and was more repeatable in defending upright postural control against the same axial loads. This method provides a foundation for future studies of neuromuscular control with axial perturbation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Associations of Perceived and Objectively Measured Neighborhood Environmental Attributes With Leisure-Time Sitting for Transport.

    PubMed

    Liao, Yung; Sugiyama, Takemi; Shibata, Ai; Ishii, Kaori; Inoue, Shigeru; Koohsari, Mohammad Javad; Owen, Neville; Oka, Koichiro

    2016-12-01

    This study examined associations of perceived and objectively measured neighborhood environmental attributes with leisure-time sitting for transport among middle-to-older aged Japanese adults. Data were collected using a postal survey of 998 adults aged 40 to 69 years. Generalized linear modeling with a gamma distribution and a log link was used to examine associations of perceived (International Physical Activity Questionnaire-Environmental module) and Geographic Information Systems (GIS)-derived built environment attributes with self-reported leisure-time sitting for transport. Mean leisure-time sitting time for transport was 20.4 min/day. After adjusting for potential confounders, perceived higher residential density, GIS-measured higher population density, better access to destinations, better access to public transport, longer sidewalk length, and higher street connectivity, were associated significantly with lower sitting time for transport. Residents living in neighborhoods with attributes previously found to be associated with more walking tended to spend less time sitting for transport during leisure-time. The health benefits of walkability-related attributes may accrue not only through increased physical activity, but also through less sedentary time.

  13. Estimating Clothing Thermal Insulation Using an Infrared Camera

    PubMed Central

    Lee, Jeong-Hoon; Kim, Young-Keun; Kim, Kyung-Soo; Kim, Soohyun

    2016-01-01

    In this paper, a novel algorithm for estimating clothing insulation is proposed to assess thermal comfort, based on the non-contact and real-time measurements of the face and clothing temperatures by an infrared camera. The proposed method can accurately measure the clothing insulation of various garments under different clothing fit and sitting postures. The proposed estimation method is investigated to be effective to measure its clothing insulation significantly in different seasonal clothing conditions using a paired t-test in 99% confidence interval. Temperatures simulated with the proposed estimated insulation value show closer to the values of actual temperature than those with individual clothing insulation values. Upper clothing’s temperature is more accurate within 3% error and lower clothing’s temperature is more accurate by 3.7%~6.2% error in indoor working scenarios. The proposed algorithm can reflect the effect of air layer which makes insulation different in the calculation to estimate clothing insulation using the temperature of the face and clothing. In future, the proposed method is expected to be applied to evaluate the customized passenger comfort effectively. PMID:27005625

  14. General view of a fully assembled Solid Rocket Booster sitting ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    General view of a fully assembled Solid Rocket Booster sitting atop the Mobile Launch Platform in the Vehicle Assembly Building at Kennedy Space Center - Space Transportation System, Solid Rocket Boosters, Lyndon B. Johnson Space Center, 2101 NASA Parkway, Houston, Harris County, TX

  15. Adipose Tissue Responses to Breaking Sitting in Men and Women with Central Adiposity.

    PubMed

    Chen, Yung-Chih; Betts, James A; Walhin, Jean-Philippe; Thompson, Dylan

    2018-04-27

    Breaking prolonged sitting reduces postprandial glucose and insulin concentrations and influences skeletal muscle molecular signalling pathways but it is unknown whether breaking sitting also affects adipose tissue. Eleven central overweight participants (7 men and 4 post-menopausal women) aged 50 ± 5 years (means ± SD) completed two mixed-meal feeding trials (PROLONGED SITTING versus BREAKING SITTING) in a randomised, counterbalanced design. The BREAKING SITTING intervention comprised walking for 2 min every 20 min over 5.5 h. Blood samples were taken at regular intervals to examine metabolic biomarkers and adipokine concentrations. Adipose tissue samples were taken at baseline and at 5.5 h to examine changes in mRNA expression and secretion of selected adipokines ex-vivo. Postprandial glycaemia and insulinaemia were attenuated by approximately 50% and 40% in BREAKING SITTING compared to PROLONGED SITTING (iAUC: 359 ± 117 versus 697 ± 218 mmol·330 min·L, p = 0.001 and 202 ± 71 versus 346 ± 150 nmol·330 min·L, p = 0.001, respectively). Despite these pronounced and sustained differences in postprandial glucose and insulin concentrations, adipose tissue mRNA expression for various genes (IL-6, leptin, adiponectin, PDK4, IRS1/2, PI3K and Akt1, etc.) and ex-vivo adipose tissue secretion of IL-6, leptin and adiponectin were not different between trials. This study demonstrates that breaking sitting with short bouts of physical activity has very pronounced effects on systemic postprandial glucose and insulin concentrations but this does not translate into corresponding effects within adipose tissue.

  16. Development of custom measurement system for biomechanical evaluation of independent wheelchair transfers.

    PubMed

    Koontz, Alicia M; Lin, Yen-Sheng; Kankipati, Padmaja; Boninger, Michael L; Cooper, Rory A

    2011-01-01

    This study describes a new custom measurement system designed to investigate the biomechanics of sitting-pivot wheelchair transfers and assesses the reliability of selected biomechanical variables. Variables assessed include horizontal and vertical reaction forces underneath both hands and three-dimensional trunk, shoulder, and elbow range of motion. We examined the reliability of these measures between 5 consecutive transfer trials for 5 subjects with spinal cord injury and 12 nondisabled subjects while they performed a self-selected sitting pivot transfer from a wheelchair to a level bench. A majority of the biomechanical variables demonstrated moderate to excellent reliability (r > 0.6). The transfer measurement system recorded reliable and valid biomechanical data for future studies of sitting-pivot wheelchair transfers.We recommend a minimum of five transfer trials to obtain a reliable measure of transfer technique for future studies.

  17. Space station ECLSS simplified integrated test

    NASA Technical Reports Server (NTRS)

    Schunk, Richard G.; Bagdigian, Robert M.; Carrasquillo, Robyn L.; Ogle, Kathyrn Y.; Wieland, Paul O.

    1989-01-01

    A discussion of the Space Station Simplified Integrated Test (SIT) was conducted. The first in a series of three integrated Environmental Control and Life Support (ECLS) system tests, the primary objectives of the SIT were to verify proper operation of ECLS subsystems functioning in an integrated fashion as well as to gather preliminary performance data for the partial ECLS system used in the test. A description of the SIT configuration, a summary of events, a discussion of anomalies that occurred during the test, and detailed results and analysis from individual measurements and water and gas samples taken during the test are included. The preprototype ECLS hardware used in the test is reported providing an overall process description and theory of operation for each hardware item.

  18. Space Station Freedom environmental control and life support system phase 3 simplified integrated test detailed report

    NASA Technical Reports Server (NTRS)

    Roberts, B. C.; Carrasquillo, R. L.; Dubiel, M. Y.; Ogle, K. Y.; Perry, J. L.; Whitley, K. M.

    1990-01-01

    A description of the phase 3 simplified integrated test (SIT) conducted at the Marshall Space Flight Center (MSFC) Core Module Integration Facility (CMIF) in 1989 is presented. This was the first test in the phase 3 series integrated environmental control and life support systems (ECLSS) tests. The basic goal of the SIT was to achieve full integration of the baseline air revitalization (AR) subsystems for Space Station Freedom. Included is a description of the SIT configuration, a performance analysis of each subsystem, results from air and water sampling, and a discussion of lessons learned from the test. Also included is a full description of the preprototype ECLSS hardware used in the test.

  19. Evaluation of Game Performance in Elite Male Sitting Volleyball Players.

    PubMed

    Molik, Bartosz; Morgulec-Adamowicz, Natalia; Marszałek, Jolanta; Kosmol, Andrzej; Rutkowska, Izabela; Jakubicka, Alicja; Kaliszewska, Ewelina; Kozłowski, Robert; Kurowska, Monika; Ploch, Elwira; Mustafins, Pavel; Gómez, Miguel-Ángel

    2017-04-01

    The aims of the current study were (a) to analyze the differences in game performances of sitting volleyball athletes representing the different types of disabilities and (b) to assess whether the seated position vertical reach is one of the crucial factors in the game performance level of sitting volleyball athletes. One hundred male athletes from various national teams participating in the European Championships in Sitting Volleyball (2009) took part in this study. The athletes were categorized according to type of disability and the results of the vertical reach in a seated position. Thirtysix games were analyzed using the Game Performance Sheet for Sitting Volleyball. Twenty-three game performance parameters were studied. In addition, the sum and effectiveness of attacks, blocks, block services, services, ball receiving, and defensive actions were calculated. The main results indicated significant differences between athletes with minimal disability and athletes with single amputations from above the knee in the level of defensive performances and the summation of defensive actions. There was also a significant difference between athletes in relation to their vertical reach during activity and attacking actions, blocks, and ball receiving. In addition, there were strong relationships between the players' vertical reach scores and their activity and effectiveness in sitting volleyball. In conclusion, the accuracy of the World Organization Volleyball for Disabled classification systems for sitting volleyball players was confirmed. There is a strong relationship between players' vertical reach and their effectiveness in sitting volleyball.

  20. Situational Awareness from a Low-Cost Camera System

    NASA Technical Reports Server (NTRS)

    Freudinger, Lawrence C.; Ward, David; Lesage, John

    2010-01-01

    A method gathers scene information from a low-cost camera system. Existing surveillance systems using sufficient cameras for continuous coverage of a large field necessarily generate enormous amounts of raw data. Digitizing and channeling that data to a central computer and processing it in real time is difficult when using low-cost, commercially available components. A newly developed system is located on a combined power and data wire to form a string-of-lights camera system. Each camera is accessible through this network interface using standard TCP/IP networking protocols. The cameras more closely resemble cell-phone cameras than traditional security camera systems. Processing capabilities are built directly onto the camera backplane, which helps maintain a low cost. The low power requirements of each camera allow the creation of a single imaging system comprising over 100 cameras. Each camera has built-in processing capabilities to detect events and cooperatively share this information with neighboring cameras. The location of the event is reported to the host computer in Cartesian coordinates computed from data correlation across multiple cameras. In this way, events in the field of view can present low-bandwidth information to the host rather than high-bandwidth bitmap data constantly being generated by the cameras. This approach offers greater flexibility than conventional systems, without compromising performance through using many small, low-cost cameras with overlapping fields of view. This means significant increased viewing without ignoring surveillance areas, which can occur when pan, tilt, and zoom cameras look away. Additionally, due to the sharing of a single cable for power and data, the installation costs are lower. The technology is targeted toward 3D scene extraction and automatic target tracking for military and commercial applications. Security systems and environmental/ vehicular monitoring systems are also potential applications.

  1. Agreement between fiber optic and optoelectronic systems for quantifying sagittal plane spinal curvature in sitting.

    PubMed

    Cloud, Beth A; Zhao, Kristin D; Breighner, Ryan; Giambini, Hugo; An, Kai-Nan

    2014-07-01

    Spinal posture affects how individuals function from a manual wheelchair. There is a need to directly quantify spinal posture in this population to ultimately improve function. A fiber optic system, comprised of an attached series of sensors, is promising for measuring large regions of the spine in individuals sitting in a wheelchair. The purpose of this study was to determine the agreement between fiber optic and optoelectronic systems for measuring spinal curvature, and describe the range of sagittal plane spinal curvatures in natural sitting. Able-bodied adults (n = 26, 13 male) participated. Each participant assumed three sitting postures: natural, slouched (accentuated kyphosis), and extension (accentuated lordosis) sitting. Fiber optic (ShapeTape) and optoelectronic (Optotrak) systems were applied to the skin over spinous processes from S1 to C7 and used to measure sagittal plane spinal curvature. Regions of kyphosis and lordosis were identified. A Cobb angle-like method was used to quantify lordosis and kyphosis. Generalized linear model and Bland-Altman analyses were used to assess agreement. A strong correlation exists between curvature values obtained with Optotrak and ShapeTape (R(2) = 0.98). The mean difference between Optotrak and ShapeTape for kyphosis in natural, extension, and slouched postures was 4.30° (95% LOA: -3.43 to 12.04°), 3.64° (95% LOA: -1.07 to 8.36°), and 4.02° (95% LOA: -2.80 to 10.84°), respectively. The mean difference for lordosis, when present, in natural and extension postures was 2.86° (95% LOA: -1.18 to 6.90°) and 2.55° (95% LOA: -3.38 to 8.48°), respectively. In natural sitting, the mean ± SD of kyphosis values was 35.07 ± 6.75°. Lordosis was detected in 8/26 participants: 11.72 ± 7.32°. The fiber optic and optoelectronic systems demonstrate acceptable agreement for measuring sagittal plane thoracolumbar spinal curvature. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Large-format platinum silicide microwave kinetic inductance detectors for optical to near-IR astronomy.

    PubMed

    Szypryt, P; Meeker, S R; Coiffard, G; Fruitwala, N; Bumble, B; Ulbricht, G; Walter, A B; Daal, M; Bockstiegel, C; Collura, G; Zobrist, N; Lipartito, I; Mazin, B A

    2017-10-16

    We have fabricated and characterized 10,000 and 20,440 pixel Microwave Kinetic Inductance Detector (MKID) arrays for the Dark-speckle Near-IR Energy-resolved Superconducting Spectrophotometer (DARKNESS) and the MKID Exoplanet Camera (MEC). These instruments are designed to sit behind adaptive optics systems with the goal of directly imaging exoplanets in a 800-1400 nm band. Previous large optical and near-IR MKID arrays were fabricated using substoichiometric titanium nitride (TiN) on a silicon substrate. These arrays, however, suffered from severe non-uniformities in the TiN critical temperature, causing resonances to shift away from their designed values and lowering usable detector yield. We have begun fabricating DARKNESS and MEC arrays using platinum silicide (PtSi) on sapphire instead of TiN. Not only do these arrays have much higher uniformity than the TiN arrays, resulting in higher pixel yields, they have demonstrated better spectral resolution than TiN MKIDs of similar design. PtSi MKIDs also do not display the hot pixel effects seen when illuminating TiN on silicon MKIDs with photons with wavelengths shorter than 1 µm.

  3. System Synchronizes Recordings from Separated Video Cameras

    NASA Technical Reports Server (NTRS)

    Nail, William; Nail, William L.; Nail, Jasper M.; Le, Doung T.

    2009-01-01

    A system of electronic hardware and software for synchronizing recordings from multiple, physically separated video cameras is being developed, primarily for use in multiple-look-angle video production. The system, the time code used in the system, and the underlying method of synchronization upon which the design of the system is based are denoted generally by the term "Geo-TimeCode(TradeMark)." The system is embodied mostly in compact, lightweight, portable units (see figure) denoted video time-code units (VTUs) - one VTU for each video camera. The system is scalable in that any number of camera recordings can be synchronized. The estimated retail price per unit would be about $350 (in 2006 dollars). The need for this or another synchronization system external to video cameras arises because most video cameras do not include internal means for maintaining synchronization with other video cameras. Unlike prior video-camera-synchronization systems, this system does not depend on continuous cable or radio links between cameras (however, it does depend on occasional cable links lasting a few seconds). Also, whereas the time codes used in prior video-camera-synchronization systems typically repeat after 24 hours, the time code used in this system does not repeat for slightly more than 136 years; hence, this system is much better suited for long-term deployment of multiple cameras.

  4. Long working distance optical coherence tomography for pediatric imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Qian, Ruobing; Carrasco-Zevallos, Oscar; Vajzovic, Lejla; Gramatikov, Boris I.; Guyton, David L.; Toth, Cynthia A.; Izatt, Joseph A.

    2016-03-01

    Conventional optical coherence tomography (OCT) systems have working distances of about 25 mm, and require cooperative subjects to immobilize and fixate on a target. Handheld OCT probes have also been demonstrated for successful imaging of pre-term infants and neonates up to ~1 year old. However, no technology yet exists for OCT in young children due to their lack of attention and inherent fear of large objects close to their face. In this work, we demonstrate a prototype retinal swept-source OCT system with a long working distance (from the last optical element to the subject's eye) to facilitate pediatric imaging. To reduce the footprint and weight of the system compared to the conventional 4f scheme, a novel 2f scanning configuration was implemented to achieve a working distance of 348mm with a +/- 8° scanning angle prior to cornea. Employing two custom-designed lenses, the system design resolution was nearly diffraction limited throughout a -8D to +5D refractive corrections. A fixation target displayed on a LCD monitor and an iris camera were used to facilitate alignment and imaging. Our prototype was tested in consented adult subjects and has the potential to facilitate imaging of young children. With this apparatus, young children could potentially sit comfortably in caretaker's lap while viewing entertainment on the fixation screen designed to direct their gaze into the imaging apparatus.

  5. The development and validation of an activity monitoring system for use in measurement of posture of childbearing women during first stage of labor.

    PubMed

    Martin, Caroline J Hollins; Kenney, Laurence; Pratt, Thomas; Granat, Malcolm H

    2015-01-01

    There is limited understanding of the type and extent of maternal postures that midwives should encourage or support during labor. The aims of this study were to identify a set of postures and movements commonly seen during labor, to develop an activity monitoring system for use during labor, and to validate this system design. Volunteer student midwives simulated maternal activity during labor in a laboratory setting. Participants (N = 15) wore monitors adhered to the left thigh and left shank, and adopted 13 common postures of laboring women for 3 minutes each. Simulated activities were recorded using a video camera. Postures and movements were coded from the video, and statistical analysis conducted of agreement between coded video data and outputs of the activity monitoring system. Excellent agreement between the 2 raters of the video recordings was found (Cohen's κ = 0.95). Both sensitivity and specificity of the activity monitoring system were greater than 80% for standing, lying, kneeling, and sitting (legs dangling). This validated system can be used to measure elected activity of laboring women and report on effects of postures on length of first stage, pain experience, birth satisfaction, and neonatal condition. This validated maternal posture-monitoring system is available as a reference-and for use by researchers who wish to develop research in this area. © 2015 by the American College of Nurse-Midwives.

  6. Development of custom measurement system for biomechanical evaluation of independent wheelchair transfers

    PubMed Central

    Koontz, Alicia M.; Lin, Yen-Sheng; Kankipati, Padmaja; Boninger, Michael L.; Cooper, Rory A.

    2017-01-01

    This study describes a new custom measurement system designed to investigate the biomechanics of sitting-pivot wheelchair transfers and assesses the reliability of selected biomechanical variables. Variables assessed include horizontal and vertical reaction forces underneath both hands and three-dimensional trunk, shoulder, and elbow range of motion. We examined the reliability of these measures between 5 consecutive transfer trials for 5 subjects with spinal cord injury and 12 non-disabled subjects while they performed a self-selected sitting pivot transfer from a wheelchair to a level bench. A majority of the biomechanical variables demonstrated moderate to excellent reliability (r > 0.6). The transfer measurement system recorded reliable and valid biomechanical data for future studies of sitting-pivot wheelchair transfers. We recommend a minimum of five transfer trials to obtain a reliable measure of transfer technique for future studies. PMID:22068376

  7. Prolonged restricted sitting effects in UH-60 helicopters.

    PubMed

    Games, Kenneth E; Lakin, Joni M; Quindry, John C; Weimar, Wendi H; Sefton, JoEllen M

    2015-01-01

    Advances in flight technologies and the demand for long-range flight have increased mission lengths for U.S. Army Black Hawk UH-60 crewmembers. Prolonged mission times have increased reports of pilot discomfort and symptoms of paresthesia thought to be due to UH-60 seat design and areas of locally high pressure. Discomfort created by the seat-system decreases situational awareness, putting aviators and support crew at risk of injury. Therefore, the purpose of this study was to examine the effects of prolonged restricted sitting in a UH-60 on discomfort, sensory function, and vascular measures in the lower extremities. There were 15 healthy men (age = 23.4 ± 3.1 yr) meeting physical flight status requirements who sat in an unpadded, UH-60 pilot's seat for 4 h while completing a common cognitive task. During the session, subjective discomfort, sensory function, and vascular function were measured. Across 4 h of restricted sitting, subjective discomfort increased using the Category Partitioning Scale (30.27 point increase) and McGill Pain Questionnaire (8.53 point increase); lower extremity sensory function was diminished along the S1 dermatome; and skin temperature decreased on both the lateral (2.85°C decrease) and anterior (2.78°C decrease) aspects of the ankle. The results suggest that prolonged sitting in a UH-60 seat increases discomfort, potentially through a peripheral nervous or vascular system mechanism. Further research is needed to understand the etiology and onset of pain and paresthesia during prolonged sitting in UH-60 pilot seats. Games KE, Lakin JM, Quindry JC, Weimar WH, Sefton JM. Prolonged restricted sitting effects in UH-60 helicopters.

  8. Effects of breaking up sitting on adolescents' postprandial glucose after consuming meals varying in energy: a cross-over randomised trial.

    PubMed

    Fletcher, Elly A; Salmon, Jo; McNaughton, Sarah A; Orellana, Liliana; Wadley, Glenn D; Bruce, Clinton; Dempsey, Paddy C; Lacy, Kathleen E; Dunstan, David W

    2018-03-01

    To explore the impact of uninterrupted sitting versus sitting with resistance-type activity breaks on adolescents' postprandial glucose responses while consuming a diet varying in energy. Cross-over randomised trial. Thirteen healthy participants (16.4±1.3years) completed a four-treatment cross-over trial: (1) uninterrupted sitting+high-energy diet; (2) sitting with breaks+high-energy diet; (3) uninterrupted sitting+standard-energy diet; and (4) sitting with breaks+standard-energy diet. For all four conditions, two identical meals were consumed; at 0h and 3h. A continuous glucose monitoring system (CGM) recorded interstitial glucose concentrations every five minutes. Linear mixed models examined differences in glucose positive incremental area under the curve (iAUC) and total AUC between the sitting and diet conditions for the first meal, second meal and entire trial period. Compared to the uninterrupted sitting conditions, the breaks condition elicited a 36.0mmol/L/h (95%CI 6.6-65.5) and 35.9mmol/L/h (95%CI 6.6-65.5) lower iAUC response after the first and second meal, respectively, but not for the entire trial period or for total AUC. Compared to the standard-energy diet, the high-energy diet elicited a 55.0mmol/L/h (95%CI 25.8-84.2) and 75.7mmol/L/h (95%CI 8.6-142.7) higher iAUC response after the first meal and entire trial, respectively. Similar response to the high-energy diet were observed for total AUC. According to iAUC, interrupting sitting had a significant effect on lowering postprandial glucose for both dietary conditions, however, it was not significant when examining total AUC. Larger studies are needed to confirm these findings. ACTRN12615001145594. Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  9. Ergonomics and the standing desk.

    PubMed

    Mula, Allison

    2018-05-28

    There has been a recent trend in the integration of sit-stand option desks in the work place. Fear-based advertising insinuating that sitting is the health equivalent of smoking has pervaded many work environments. As workers want to remain healthy and pain free, and employers want and need a healthy workforce, it appears that there is a pervasive trend of avoiding sitting as often as possible. Because work tasks that call for an extensive amount of sitting are often times computer-based, this 'standing is healthy' fad is most notably presenting itself at computer-based work stations. The understandably perceived simple fix to the dilemma of sitting, has been the introduction of the sit-stand desk. However, before we all throw out our chairs, it is important to discuss the past and recent research that indicates that prolonged standing can also have detrimental effects on the human system. It is crucial that we expand our idea of a healthy work environment to one that facilitates movement and change in position and empowers the worker to understand their role in their own musculoskeletal and physiological health and wellness, beyond the use of equipment. If we can replace the phrase, 'sitting is the new smoking' with the phrase, 'sedentary is the new smoking', then we can elucidate the idea of what a healthy computer-based work environment and routine would be.

  10. Quantitative Multispectral Analysis Of Discrete Subcellular Particles By Digital Imaging Fluorescence Microscopy (DIFM)

    NASA Astrophysics Data System (ADS)

    Dorey, C. K.; Ebenstein, David B.

    1988-10-01

    Subcellular localization of multiple biochemical markers is readily achieved through their characteristic autofluorescence or through use of appropriately labelled antibodies. Recent development of specific probes has permitted elegant studies in calcium and pH in living cells. However, each of these methods measured fluorescence at one wavelength; precise quantitation of multiple fluorophores at individual sites within a cell has not been possible. Using DIFM, we have achieved spectral analysis of discrete subcellular particles 1-2 gm in diameter. The fluorescence emission is broken into narrow bands by an interference monochromator and visualized through the combined use of a silicon intensified target (SIT) camera, a microcomputer based framegrabber with 8 bit resolution, and a color video monitor. Image acquisition, processing, analysis and display are under software control. The digitized image can be corrected for the spectral distortions induced by the wavelength dependent sensitivity of the camera, and the displayed image can be enhanced or presented in pseudocolor to facilitate discrimination of variation in pixel intensity of individual particles. For rapid comparison of the fluorophore composition of granules, a ratio image is produced by dividing the image captured at one wavelength by that captured at another. In the resultant ratio image, a granule which has a fluorophore composition different from the majority is selectively colored. This powerful system has been utilized to obtain spectra of endogenous autofluorescent compounds in discrete cellular organelles of human retinal pigment epithelium, and to measure immunohistochemically labelled components of the extracellular matrix associated with the human optic nerve.

  11. Why Older Adults Spend Time Sedentary and Break Their Sedentary Behavior: A Mixed-Methods Approach Using Life-Logging Equipment.

    PubMed

    Dontje, Manon L; Leask, Calum F; Harvey, Juliet; Skelton, Dawn A; Chastin, Sebastien F M

    2018-04-01

    Older adults are recommended to reduce their sedentary time to promote healthy ageing. To develop effective interventions identifying when, why, and how older adults are able to change their sitting habits is important. The aim of this mixed-method study was to improve our understanding of reasons for (breaking) sedentary behavior in older adults. Thirty older adults (74.0 [±5.3] years old, 73% women) were asked about their believed reasons for (breaking) sedentary behavior, and about their actual reasons when looking at a personal storyboard with objective records of activPAL monitor data and time-lapse camera pictures showing all their periods of sedentary time in a day. The most often mentioned believed reason for remaining sedentary was television/radio (mentioned by 48.3%), while eating/drinking was most often mentioned as actual reason (96.6%). Only 17.2% believed that food/tea preparation was a reason to break up sitting, while this was an actual reason for 82.8% of the study sample. Results of this study show that there is a discrepancy between believed and actual reasons for (breaking) sedentary behavior. These findings suggest developing interventions utilizing the actual reasons for breaking sedentary behavior to reduce sedentary time in older adults.

  12. Sitting position does not alter minimum alveolar concentration for desflurane.

    PubMed

    Lin, Chun-Ming; Wu, Chieh-Tsai; Lee, Shih-Tseng; Lui, Tai-Ngar; Huang, Chia-Chun; Li, Allen Hon-Lun; Doufas, Anthony G

    2007-07-01

    Hypotension is a common complication of the sitting position during anesthesia, and is often counteracted by decreasing anesthetic depth, thereby exposing patients to the risk of being inadequately anesthetized. Baroreceptor unloading and the consequent sympathoexcitation, as during head up tilt, decreases pain threshold and arouses the central nervous system (CNS), whereas hypotension exerts a direct CNS depressant effect. We estimated the minimal alveolar concentration (MAC) of desflurane for immobility in patients undergoing surgery in the sitting position, in comparison to MAC desflurane for patients having a similar type of surgery in the supine position. The Dixon up-and-down method was used to evaluate the MAC for desflurane in patients undergoing cervical spine laminoplasty (n = 24) or discectomy (n = 24) in the sitting and supine positions, respectively. Logistic regression with co-variate adjustment was employed to examine if the two positions (sitting and supine) have different or share the same concentration vs response relationship for immobility. Monte Carlo simulation was used to calculate 95% confidence intervals (CI) for the MAC in each position, and to estimate the difference in MAC (delta MAC) between the sitting and supine positions. Modeling both sitting [6.54% (6.50-6.66, 95% CI)] and supine [6.70 (6.55-6.81)] patients as having different MAC concentrations did not significantly improve our simplified model, which treats the two patient groups as one [6.61 (6.52-6.70), delta -2 log likelihood = 2.735, P = 0.098]. Mean delta MAC (95% CI) was -0.14 (-0.30, 0.03). The sitting position does not change desflurane anesthetic requirements for immobility.

  13. Automatic multi-camera calibration for deployable positioning systems

    NASA Astrophysics Data System (ADS)

    Axelsson, Maria; Karlsson, Mikael; Rudner, Staffan

    2012-06-01

    Surveillance with automated positioning and tracking of subjects and vehicles in 3D is desired in many defence and security applications. Camera systems with stereo or multiple cameras are often used for 3D positioning. In such systems, accurate camera calibration is needed to obtain a reliable 3D position estimate. There is also a need for automated camera calibration to facilitate fast deployment of semi-mobile multi-camera 3D positioning systems. In this paper we investigate a method for automatic calibration of the extrinsic camera parameters (relative camera pose and orientation) of a multi-camera positioning system. It is based on estimation of the essential matrix between each camera pair using the 5-point method for intrinsically calibrated cameras. The method is compared to a manual calibration method using real HD video data from a field trial with a multicamera positioning system. The method is also evaluated on simulated data from a stereo camera model. The results show that the reprojection error of the automated camera calibration method is close to or smaller than the error for the manual calibration method and that the automated calibration method can replace the manual calibration.

  14. The sequence measurement system of the IR camera

    NASA Astrophysics Data System (ADS)

    Geng, Ai-hui; Han, Hong-xia; Zhang, Hai-bo

    2011-08-01

    Currently, the IR cameras are broadly used in the optic-electronic tracking, optic-electronic measuring, fire control and optic-electronic countermeasure field, but the output sequence of the most presently applied IR cameras in the project is complex and the giving sequence documents from the leave factory are not detailed. Aiming at the requirement that the continuous image transmission and image procession system need the detailed sequence of the IR cameras, the sequence measurement system of the IR camera is designed, and the detailed sequence measurement way of the applied IR camera is carried out. The FPGA programming combined with the SignalTap online observation way has been applied in the sequence measurement system, and the precise sequence of the IR camera's output signal has been achieved, the detailed document of the IR camera has been supplied to the continuous image transmission system, image processing system and etc. The sequence measurement system of the IR camera includes CameraLink input interface part, LVDS input interface part, FPGA part, CameraLink output interface part and etc, thereinto the FPGA part is the key composed part in the sequence measurement system. Both the video signal of the CmaeraLink style and the video signal of LVDS style can be accepted by the sequence measurement system, and because the image processing card and image memory card always use the CameraLink interface as its input interface style, the output signal style of the sequence measurement system has been designed into CameraLink interface. The sequence measurement system does the IR camera's sequence measurement work and meanwhile does the interface transmission work to some cameras. Inside the FPGA of the sequence measurement system, the sequence measurement program, the pixel clock modification, the SignalTap file configuration and the SignalTap online observation has been integrated to realize the precise measurement to the IR camera. Te sequence measurement program written by the verilog language combining the SignalTap tool on line observation can count the line numbers in one frame, pixel numbers in one line and meanwhile account the line offset and row offset of the image. Aiming at the complex sequence of the IR camera's output signal, the sequence measurement system of the IR camera accurately measures the sequence of the project applied camera, supplies the detailed sequence document to the continuous system such as image processing system and image transmission system and gives out the concrete parameters of the fval, lval, pixclk, line offset and row offset. The experiment shows that the sequence measurement system of the IR camera can get the precise sequence measurement result and works stably, laying foundation for the continuous system.

  15. The Sit & Stand chair. A revolutionary advance in adaptive seating systems.

    PubMed

    Galumbeck, Michael H; Buschbacher, Ralph M; Wilder, Robert P; Winters, Kathryne L; Hudson, Mary Anne; Edlich, Richard F

    2004-01-01

    A major factor governing independence for the elderly and persons with disabilities is the ability to stand from a chair. Factors such as pain, reduced joint range of motion, stiffness, and muscle weakness frequently limit the ability to stand. Sit-to-stand position is even further reduced in patients whose hands and shoulders are afflicted with rheumatoid arthritis. When achieving a sit-to-stand position in the elderly and persons with disabilities, there is considerable risk of the individual falling and sustaining bone fracture. The purposes of this scientific report are to achieve the following goals: (1) to provide a narrative discussion of the senior author's contributions to furniture manufacturing as well as his successful patent application for the SIT & STAND chair, (2) to describe the steps involved in the development of the SIT & STAND prototype, and (3) to examine the performance of the SIT & STAND chair in assisting the elderly or persons with disabilities in achieving a sit-to-stand position. The invention of the SIT & STAND chair by the senior author, Michael Galumbeck, was a culmination of his lifelong interest in adaptive seating systems. His electrically operated chair has the unique ability to assist the occupant to achieve safely a sit-to-stand position. The rear portion of his chair remains in a fixed position to support the buttocks of the user during mechanical lift. The front portion of the seat folds down incrementally as the chair rises to allow the feet of the user to be positioned in a more posterior position firmly on the floor. Using its actuator, the height that the chair rises will vary with the length of the legs of the occupant. Using the drawing program Solid Works (Solid Works, Concord, Massachusetts), drawings of the chair were made. To visualize the operation and performance of the chair, separate drawings were made in the lateral position. The prototype of the SIT & STAND chair was manufactured with an electric actuator that allows elevation of the back portion of the seat. The design of this chair ensured that there were no pinch points that could endanger the user or assistant. Its framework ensured that it was stable and did not tip over. After the prototype chair is manufactured, it is being sent to Underwriters Laboratory Inc. (Los Angeles, California) for review and certification. The performance of the SIT & STAND chair was determined in a clinical study involving seven elderly or disabled individuals who complained of difficulty in rising from a chair from a seated position. During each performance evaluation, a mechanical chest and shoulder harness attached to an overhead sling encircled the individual to ensure that he/she would not fall. In the first part of the evaluation, these individuals were asked to achieve a standing position after being seated in the SIT & STAND chair without the use of the actuator. Three individuals were unable to achieve a standing position, while four achieved this standing position with considerable difficulty and potential instability. When these participants used the SIT & STAND chair with the use of the electrical actuator, all individuals achieved a standing position without difficulty or instability. All individuals expressed disappointment that the SIT & STAND chair was not commercially available for them to purchase and use in their homes. Because the SIT & STAND chair allows the individual to achieve a standing position without assistance, the SIT & STAND chair has other potential benefits not evaluated in this study. The beneficial effects of standing have been documented by comprehensive scientific studies. These benefits include reduction of seating pressure, decreased bone demineralization, increased bladder pressure, enhanced circulatory regulation, reduction in muscular tone, decrease in upper extremity muscle stress, and participation in activities of daily living. Another irrefutable benefit of the SIT & STAND chair is that the chair eliminates the need for physical assistance from family members or health care personnel, preventing the development of disabling back injuries in personal care assistants. In addition, the SIT & STAND chair entirely removes the risk of pain or harm to the individual, which sometimes occurs with manual assist to stand, such as dislocation or fracture of frail shoulders with the under-axilla lift. Realizing the medical benefits of the SIT & STAND chair, Aetna completed a clinical policy bulletin that states that the seat lift mechanism is a medically necessary durable medical product. On the basis of this extensive product and performance evaluation, we recommend the SIT & STAND chair for the elderly as well as persons with disability to safely achieve a sit-to-stand position.

  16. High-intensity high-volume swimming induces more robust signaling through PGC-1α and AMPK activation than sprint interval swimming in m. triceps brachii

    PubMed Central

    Plaza-Díaz, Julio; Ruiz-Ojeda, Francisco J.; Aragón-Vela, Jerónimo; Robles-Sanchez, Cándido; Nordsborg, Nikolai B.; Hebberecht, Marina; Salmeron, Luis M.; Huertas, Jesus R.

    2017-01-01

    We aimed to test whether high-intensity high-volume training (HIHVT) swimming would induce more robust signaling than sprint interval training (SIT) swimming within the m. triceps brachii due to lower metabolic and oxidation. Nine well-trained swimmers performed the two training procedures on separate randomized days. Muscle biopsies from m. triceps brachii and blood samples were collected at three different time points: a) before the intervention (pre), b) immediately after the swimming procedures (post) and c) after 3 h of rest (3 h). Hydroperoxides, creatine kinase (CK), and lactate dehydrogenase (LDH) were quantified from blood samples, and peroxisome proliferator-activated receptor γ coactivator 1α (PGC-1α) and the AMPKpTHR172/AMPK ratio were quantified by Western blot analysis. PGC-1α, sirtuin 3 (SIRT3), superoxide-dismutase 2 (SOD2), and vascular endothelial growth factor (VEGF) mRNA levels were also quantified. SIT induced a higher release of LDH (p < 0.01 at all time points) and CK (p < 0.01 at post) than HIHVT, but neither SIT nor HIHVT altered systemic hydroperoxides. Additionally, neither SIRT3 nor SOD2 mRNA levels increased, while PGC-1α transcription increased at 3 h after SIT (p < 0.01) and after HIHVT (p < 0.001). However, PGC-1α protein was higher after HIHVT than after SIT (p < 0.05). Moreover, the AMPKpTHR172/AMPK ratio increased at post after SIT (p < 0.05), whereas this effect was delayed after HIHVT as it increased after 3 h (p < 0.05). In addition, VEGF transcription was higher in response to HIHVT (p < 0.05). In conclusion, SIT induces higher muscular stress than HIHVT without increasing systemic oxidation. In addition, HIHVT may induce more robust oxidative adaptations through PGC-1α and AMPK. PMID:28973039

  17. High-intensity high-volume swimming induces more robust signaling through PGC-1α and AMPK activation than sprint interval swimming in m. triceps brachii.

    PubMed

    Casuso, Rafael A; Plaza-Díaz, Julio; Ruiz-Ojeda, Francisco J; Aragón-Vela, Jerónimo; Robles-Sanchez, Cándido; Nordsborg, Nikolai B; Hebberecht, Marina; Salmeron, Luis M; Huertas, Jesus R

    2017-01-01

    We aimed to test whether high-intensity high-volume training (HIHVT) swimming would induce more robust signaling than sprint interval training (SIT) swimming within the m. triceps brachii due to lower metabolic and oxidation. Nine well-trained swimmers performed the two training procedures on separate randomized days. Muscle biopsies from m. triceps brachii and blood samples were collected at three different time points: a) before the intervention (pre), b) immediately after the swimming procedures (post) and c) after 3 h of rest (3 h). Hydroperoxides, creatine kinase (CK), and lactate dehydrogenase (LDH) were quantified from blood samples, and peroxisome proliferator-activated receptor γ coactivator 1α (PGC-1α) and the AMPKpTHR172/AMPK ratio were quantified by Western blot analysis. PGC-1α, sirtuin 3 (SIRT3), superoxide-dismutase 2 (SOD2), and vascular endothelial growth factor (VEGF) mRNA levels were also quantified. SIT induced a higher release of LDH (p < 0.01 at all time points) and CK (p < 0.01 at post) than HIHVT, but neither SIT nor HIHVT altered systemic hydroperoxides. Additionally, neither SIRT3 nor SOD2 mRNA levels increased, while PGC-1α transcription increased at 3 h after SIT (p < 0.01) and after HIHVT (p < 0.001). However, PGC-1α protein was higher after HIHVT than after SIT (p < 0.05). Moreover, the AMPKpTHR172/AMPK ratio increased at post after SIT (p < 0.05), whereas this effect was delayed after HIHVT as it increased after 3 h (p < 0.05). In addition, VEGF transcription was higher in response to HIHVT (p < 0.05). In conclusion, SIT induces higher muscular stress than HIHVT without increasing systemic oxidation. In addition, HIHVT may induce more robust oxidative adaptations through PGC-1α and AMPK.

  18. Miniaturized fundus camera

    NASA Astrophysics Data System (ADS)

    Gliss, Christine; Parel, Jean-Marie A.; Flynn, John T.; Pratisto, Hans S.; Niederer, Peter F.

    2003-07-01

    We present a miniaturized version of a fundus camera. The camera is designed for the use in screening for retinopathy of prematurity (ROP). There, but also in other applications a small, light weight, digital camera system can be extremely useful. We present a small wide angle digital camera system. The handpiece is significantly smaller and lighter then in all other systems. The electronics is truly portable fitting in a standard boardcase. The camera is designed to be offered at a compatible price. Data from tests on young rabbits' eyes is presented. The development of the camera system is part of a telemedicine project screening for ROP. Telemedical applications are a perfect application for this camera system using both advantages: the portability as well as the digital image.

  19. Camera systems in human motion analysis for biomedical applications

    NASA Astrophysics Data System (ADS)

    Chin, Lim Chee; Basah, Shafriza Nisha; Yaacob, Sazali; Juan, Yeap Ewe; Kadir, Aida Khairunnisaa Ab.

    2015-05-01

    Human Motion Analysis (HMA) system has been one of the major interests among researchers in the field of computer vision, artificial intelligence and biomedical engineering and sciences. This is due to its wide and promising biomedical applications, namely, bio-instrumentation for human computer interfacing and surveillance system for monitoring human behaviour as well as analysis of biomedical signal and image processing for diagnosis and rehabilitation applications. This paper provides an extensive review of the camera system of HMA, its taxonomy, including camera types, camera calibration and camera configuration. The review focused on evaluating the camera system consideration of the HMA system specifically for biomedical applications. This review is important as it provides guidelines and recommendation for researchers and practitioners in selecting a camera system of the HMA system for biomedical applications.

  20. Automated Ecological Assessment of Physical Activity: Advancing Direct Observation.

    PubMed

    Carlson, Jordan A; Liu, Bo; Sallis, James F; Kerr, Jacqueline; Hipp, J Aaron; Staggs, Vincent S; Papa, Amy; Dean, Kelsey; Vasconcelos, Nuno M

    2017-12-01

    Technological advances provide opportunities for automating direct observations of physical activity, which allow for continuous monitoring and feedback. This pilot study evaluated the initial validity of computer vision algorithms for ecological assessment of physical activity. The sample comprised 6630 seconds per camera (three cameras in total) of video capturing up to nine participants engaged in sitting, standing, walking, and jogging in an open outdoor space while wearing accelerometers. Computer vision algorithms were developed to assess the number and proportion of people in sedentary, light, moderate, and vigorous activity, and group-based metabolic equivalents of tasks (MET)-minutes. Means and standard deviations (SD) of bias/difference values, and intraclass correlation coefficients (ICC) assessed the criterion validity compared to accelerometry separately for each camera. The number and proportion of participants sedentary and in moderate-to-vigorous physical activity (MVPA) had small biases (within 20% of the criterion mean) and the ICCs were excellent (0.82-0.98). Total MET-minutes were slightly underestimated by 9.3-17.1% and the ICCs were good (0.68-0.79). The standard deviations of the bias estimates were moderate-to-large relative to the means. The computer vision algorithms appeared to have acceptable sample-level validity (i.e., across a sample of time intervals) and are promising for automated ecological assessment of activity in open outdoor settings, but further development and testing is needed before such tools can be used in a diverse range of settings.

  1. Automated Ecological Assessment of Physical Activity: Advancing Direct Observation

    PubMed Central

    Carlson, Jordan A.; Liu, Bo; Sallis, James F.; Kerr, Jacqueline; Papa, Amy; Dean, Kelsey; Vasconcelos, Nuno M.

    2017-01-01

    Technological advances provide opportunities for automating direct observations of physical activity, which allow for continuous monitoring and feedback. This pilot study evaluated the initial validity of computer vision algorithms for ecological assessment of physical activity. The sample comprised 6630 seconds per camera (three cameras in total) of video capturing up to nine participants engaged in sitting, standing, walking, and jogging in an open outdoor space while wearing accelerometers. Computer vision algorithms were developed to assess the number and proportion of people in sedentary, light, moderate, and vigorous activity, and group-based metabolic equivalents of tasks (MET)-minutes. Means and standard deviations (SD) of bias/difference values, and intraclass correlation coefficients (ICC) assessed the criterion validity compared to accelerometry separately for each camera. The number and proportion of participants sedentary and in moderate-to-vigorous physical activity (MVPA) had small biases (within 20% of the criterion mean) and the ICCs were excellent (0.82–0.98). Total MET-minutes were slightly underestimated by 9.3–17.1% and the ICCs were good (0.68–0.79). The standard deviations of the bias estimates were moderate-to-large relative to the means. The computer vision algorithms appeared to have acceptable sample-level validity (i.e., across a sample of time intervals) and are promising for automated ecological assessment of activity in open outdoor settings, but further development and testing is needed before such tools can be used in a diverse range of settings. PMID:29194358

  2. Measuring Tissue Perfusion During Pressure Relief Maneuvers: Insights Into Preventing Pressure Ulcers

    PubMed Central

    Makhsous, Mohsen; Priebe, Michael; Bankard, James; Rowles, Diana; Zeigler, Mary; Chen, David; Lin, Fang

    2007-01-01

    Background/Objective: To study the effect on tissue perfusion of relieving interface pressure using standard wheelchair pushups compared with a mechanical automated dynamic pressure relief system. Design: Repeated measures in 2 protocols on 3 groups of subjects. Participants: Twenty individuals with motor-complete paraplegia below T4, 20 with motor-complete tetraplegia, and 20 able-bodied subjects. Methods: Two 1-hour sitting protocols: dynamic protocol, sitting configuration alternated every 10 minutes between a normal sitting configuration and an off-loading configuration; wheelchair pushup protocol, normal sitting configuration with standard wheelchair pushup once every 20 minutes. Main Outcome Measures: Transcutaneous partial pressures of oxygen and carbon dioxide measured from buttock overlying the ischial tuberosity and interface pressure measured at the seat back and buttocks. Perfusion deterioration and recovery times were calculated during changes in interface pressures. Results: In the off-loading configuration, concentrated interface pressure during the normal sitting configuration was significantly diminished, and tissue perfusion was significantly improved. Wheelchair pushups showed complete relief of interface pressure but incomplete recovery of tissue perfusion. Conclusions: Interface pressure analysis does not provide complete information about the effectiveness of pressure relief maneuvers. Measures of tissue perfusion may help establish more effective strategies. Relief achieved by standard wheelchair pushups may not be sufficient to recover tissue perfusion compromised during sitting; alternate maneuvers may be necessary. The dynamic seating system provided effective pressure relief with sustained reduction in interface pressure adequate for complete recovery of tissue perfusion. Differences in perfusion recovery times between subjects with spinal cord injury (SCI) and controls raise questions about the importance of changes in vascular responses to pressure after SCI. PMID:18092567

  3. A multipurpose camera system for monitoring Kīlauea Volcano, Hawai'i

    USGS Publications Warehouse

    Patrick, Matthew R.; Orr, Tim R.; Lee, Lopaka; Moniz, Cyril J.

    2015-01-01

    We describe a low-cost, compact multipurpose camera system designed for field deployment at active volcanoes that can be used either as a webcam (transmitting images back to an observatory in real-time) or as a time-lapse camera system (storing images onto the camera system for periodic retrieval during field visits). The system also has the capability to acquire high-definition video. The camera system uses a Raspberry Pi single-board computer and a 5-megapixel low-light (near-infrared sensitive) camera, as well as a small Global Positioning System (GPS) module to ensure accurate time-stamping of images. Custom Python scripts control the webcam and GPS unit and handle data management. The inexpensive nature of the system allows it to be installed at hazardous sites where it might be lost. Another major advantage of this camera system is that it provides accurate internal timing (independent of network connection) and, because a full Linux operating system and the Python programming language are available on the camera system itself, it has the versatility to be configured for the specific needs of the user. We describe example deployments of the camera at Kīlauea Volcano, Hawai‘i, to monitor ongoing summit lava lake activity. 

  4. Behavior Prediction Tools Strengthen Nanoelectronics

    NASA Technical Reports Server (NTRS)

    2013-01-01

    Several years ago, NASA started making plans to send robots to explore the deep, dark craters on the Moon. As part of these plans, NASA needed modeling tools to help engineer unique electronics to withstand extremely cold temperatures. According to Jonathan Pellish, a flight systems test engineer at Goddard Space Flight Center, "An instrument sitting in a shadowed crater on one of the Moon s poles would hover around 43 K", that is, 43 kelvin, equivalent to -382 F. Such frigid temperatures are one of the main factors that make the extreme space environments encountered on the Moon and elsewhere so extreme. Radiation is another main concern. "Radiation is always present in the space environment," says Pellish. "Small to moderate solar energetic particle events happen regularly and extreme events happen less than a handful of times throughout the 7 active years of the 11-year solar cycle." Radiation can corrupt data, propagate to other systems, require component power cycling, and cause a host of other harmful effects. In order to explore places like the Moon, Jupiter, Saturn, Venus, and Mars, NASA must use electronic communication devices like transmitters and receivers and data collection devices like infrared cameras that can resist the effects of extreme temperature and radiation; otherwise, the electronics would not be reliable for the duration of the mission.

  5. KSC-07pd2190

    NASA Image and Video Library

    2007-08-03

    KENNEDY SPACE CENTER, FLA. - The STS-120 crew is at Kennedy for a crew equipment interface test, or CEIT. Inspecting the thermal protection system, or TPS, tiles under space shuttle Discovery in Orbiter Processing Facility bay 3 are, from left, Expedition 16 Flight Engineer Daniel M. Tani; Mission Specialist Douglas H. Wheelock; Pilot George D. Zamka; Mission Specialist Paolo A. Nespoli (sitting), a European Space Agency astronaut from Italy; Mission Specialist Scott E. Parazynski (pointing); Commander Pamela A. Melroy; Allison Bolinger (kneeling), an EVA technician with NASA; Mission Specialist Stephanie D. Wilson; and Erin Schlichenmaier, with United Space Alliance TPS Engineering. Among the activities standard to a CEIT are harness training, inspection of the thermal protection system and camera operation for planned extravehicular activities, or EVAs. The STS-120 mission will deliver the Harmony module, christened after a school contest, which will provide attachment points for European and Japanese laboratory modules on the International Space Station. Known in technical circles as Node 2, it is similar to the six-sided Unity module that links the U.S. and Russian sections of the station. Built in Italy for the United States, Harmony will be the first new U.S. pressurized component to be added. The STS-120 mission is targeted to launch on Oct. 20. Photo credit: NASA/George Shelton

  6. [The role of investigations by János Szentágothai in developmental neurology].

    PubMed

    Katona, Ferenc; Berényi, Marianne

    2003-11-20

    The vestibulospinal system plays determining role in the activation processes of elementary sensorymotor patterns characterised by the verticalization of the trunk and elevation of the head. In the thirties of the last century János Szentágothai proved that axons of the vestibulospinal tract reach the cervical and thoracic spinal cord and innervate the muscles of the neck. Later he verified existence of various connections among the labyrinth, the vestibular system, and the motor nuclei of the III., IV. and the VI. cranial nerves. His studies explain the functional neuroanatomic background of sitting up, sitting and balancing in the air, head-elevation and head control during the execution of a special elementary sensorymotor pattern: "sitting in air". All these functions can be activated by labyrinthine stimulation long before the maturation of the corticospinal tract.

  7. Safety and immunogenicity of a cluster specific immunotherapy in children with bronchial asthma and mite allergy.

    PubMed

    Schubert, R; Eickmeier, O; Garn, H; Baer, P C; Mueller, T; Schulze, J; Rose, M A; Rosewich, M; Renz, H; Zielen, S

    2009-01-01

    Cluster specific immunotherapy (SIT) is a modern form of allergen immunotherapy allowing safe administration of high allergen doses in a short time interval compared to classic SIT. In the current study, we investigated the safety profile and immunological effect of cluster SIT in children with allergic asthma due to house dust mite allergy. A total of 34 children (6-18 years) with allergic asthma were assigned to cluster (n = 22) or classic SIT (n = 12). To achieve a maintenance dose of allergen extract, cluster patients received 14 injections of house dust mite allergen within 6 weeks, whereas the classic SIT group received 14 injections within 14 weeks. Safety was monitored by recording adverse events. Immunogenicity was measured by specific IgG(Mite) and IgG4(Mite), by antibody-blocking properties on basophil activation, and by the T cell subset transcription factors Foxp3, T-bet, and GATA-3. There were no significant differences in local and systemic side effects between the two groups. In the cluster group, serum levels of specific IgG(Mite) (p < 0.001) and specific IgG4(Mite) (p < 0.001) significantly increased after 8 weeks, while it took 12 weeks in the classic SIT group. These data were confirmed by blocking CD63 expression as well as release of cysteinyl leukotrienes after in vitro basophil stimulation. No differences in transcription factor expression were found in the two groups. Cluster SIT is safe in children. Additionally, our data demonstrated an even more rapid induction of specific immune tolerance. Cluster SIT is an attractive alternative to conventional up-dosing schedules with fewer consultations for the patients. (c) 2008 S. Karger AG, Basel.

  8. Sitting in the sun: Nest microhabitat affects incubation temperatures in seabirds.

    PubMed

    Hart, Lorinda A; Downs, Colleen T; Brown, Mark

    2016-08-01

    During incubation parent birds are committed to a nest site and endure a range of ambient conditions while regulating egg temperatures. Using artificial eggs containing temperature loggers alongside ambient temperature (Ta) controls, incubation profiles were determined for four tropical seabird species at different nest site locations. Camera traps were used for ad-hoc behavioural incubation observations. Eggs experienced a range of temperatures during incubation and varied significantly between species and in some cases between different microhabitats within a species. Such variation has important consequences in the phenotypic expression of both physical and physiological traits of chicks, and ultimately species fitness. Exposed nest sites were more strongly correlated to Tas. Camera traps highlighted different incubation strategies employed by these species that could be related to trade-offs in predator defence, feeding habits, and temperature regulation of eggs. This study provides evidence that species with similar breeding habits could be affected by environmental stressors in similar ways and that the differences shown in nest site selection could negate some of these effects. We propose that habitats providing suitable nest microclimates will become increasingly important for the successful breeding of seabird species, particularly under predicted climate change scenarios. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. LAMOST CCD camera-control system based on RTS2

    NASA Astrophysics Data System (ADS)

    Tian, Yuan; Wang, Zheng; Li, Jian; Cao, Zi-Huang; Dai, Wei; Wei, Shou-Lin; Zhao, Yong-Heng

    2018-05-01

    The Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST) is the largest existing spectroscopic survey telescope, having 32 scientific charge-coupled-device (CCD) cameras for acquiring spectra. Stability and automation of the camera-control software are essential, but cannot be provided by the existing system. The Remote Telescope System 2nd Version (RTS2) is an open-source and automatic observatory-control system. However, all previous RTS2 applications were developed for small telescopes. This paper focuses on implementation of an RTS2-based camera-control system for the 32 CCDs of LAMOST. A virtual camera module inherited from the RTS2 camera module is built as a device component working on the RTS2 framework. To improve the controllability and robustness, a virtualized layer is designed using the master-slave software paradigm, and the virtual camera module is mapped to the 32 real cameras of LAMOST. The new system is deployed in the actual environment and experimentally tested. Finally, multiple observations are conducted using this new RTS2-framework-based control system. The new camera-control system is found to satisfy the requirements for automatic camera control in LAMOST. This is the first time that RTS2 has been applied to a large telescope, and provides a referential solution for full RTS2 introduction to the LAMOST observatory control system.

  10. Motion Estimation Utilizing Range Detection-Enhanced Visual Odometry

    NASA Technical Reports Server (NTRS)

    Morris, Daniel Dale (Inventor); Chang, Hong (Inventor); Friend, Paul Russell (Inventor); Chen, Qi (Inventor); Graf, Jodi Seaborn (Inventor)

    2016-01-01

    A motion determination system is disclosed. The system may receive a first and a second camera image from a camera, the first camera image received earlier than the second camera image. The system may identify corresponding features in the first and second camera images. The system may receive range data comprising at least one of a first and a second range data from a range detection unit, corresponding to the first and second camera images, respectively. The system may determine first positions and the second positions of the corresponding features using the first camera image and the second camera image. The first positions or the second positions may be determined by also using the range data. The system may determine a change in position of the machine based on differences between the first and second positions, and a VO-based velocity of the machine based on the determined change in position.

  11. Differences in glance behavior between drivers using a rearview camera, parking sensor system, both technologies, or no technology during low-speed parking maneuvers.

    PubMed

    Kidd, David G; McCartt, Anne T

    2016-02-01

    This study characterized the use of various fields of view during low-speed parking maneuvers by drivers with a rearview camera, a sensor system, a camera and sensor system combined, or neither technology. Participants performed four different low-speed parking maneuvers five times. Glances to different fields of view the second time through the four maneuvers were coded along with the glance locations at the onset of the audible warning from the sensor system and immediately after the warning for participants in the sensor and camera-plus-sensor conditions. Overall, the results suggest that information from cameras and/or sensor systems is used in place of mirrors and shoulder glances. Participants with a camera, sensor system, or both technologies looked over their shoulders significantly less than participants without technology. Participants with cameras (camera and camera-plus-sensor conditions) used their mirrors significantly less compared with participants without cameras (no-technology and sensor conditions). Participants in the camera-plus-sensor condition looked at the center console/camera display for a smaller percentage of the time during the low-speed maneuvers than participants in the camera condition and glanced more frequently to the center console/camera display immediately after the warning from the sensor system compared with the frequency of glances to this location at warning onset. Although this increase was not statistically significant, the pattern suggests that participants in the camera-plus-sensor condition may have used the warning as a cue to look at the camera display. The observed differences in glance behavior between study groups were illustrated by relating it to the visibility of a 12-15-month-old child-size object. These findings provide evidence that drivers adapt their glance behavior during low-speed parking maneuvers following extended use of rearview cameras and parking sensors, and suggest that other technologies which augment the driving task may do the same. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Dual cameras acquisition and display system of retina-like sensor camera and rectangular sensor camera

    NASA Astrophysics Data System (ADS)

    Cao, Nan; Cao, Fengmei; Lin, Yabin; Bai, Tingzhu; Song, Shengyu

    2015-04-01

    For a new kind of retina-like senor camera and a traditional rectangular sensor camera, dual cameras acquisition and display system need to be built. We introduce the principle and the development of retina-like senor. Image coordinates transformation and interpolation based on sub-pixel interpolation need to be realized for our retina-like sensor's special pixels distribution. The hardware platform is composed of retina-like senor camera, rectangular sensor camera, image grabber and PC. Combined the MIL and OpenCV library, the software program is composed in VC++ on VS 2010. Experience results show that the system can realizes two cameras' acquisition and display.

  13. A reliability of the prototype trunk training system for sitting balance.

    PubMed

    Jeong, Juri; Park, Dae-Sung; Lee, Hyelim; Eun, Seondeok

    2014-11-01

    [Purpose] Cerebral palsy is a disorder that affects balance in the sitting position. Cerebral palsy patients need trunk muscle strengthening and balance training. In order to improve trunk control sensory-motor control training is carried out on an unstable surface. We have developed a Trunk Training System (TTS) that can provide visual feedback using a tilt sensor for balance training in the sitting position. Before using the TTS for training children with cerebral palsy experiments were conducted with healthy adult subjects and the TTS to gather basic data for its improvement. [Subjects] The subjects were 11 healthy men (n=3) and women (n=8). [Methods] Subjects trained at two levels (5°, 10°), in four different directions (anterior, posterior, left, right), three times each. TTS outcome indices (stability index, performance time) were measured. [Results] The stability index and performance time showed high correlation (-0.6

  14. Glass-type wireless PPG measuring system.

    PubMed

    Lee, E M; Shin, J Y; Hong, J H; Cha, E J; Lee, T S

    2010-01-01

    This paper is about a glass-type wireless bio-signal transmitter that can monitor the user's health state in daily life. The device implemented in this study consists of the transmission part and the receiving part. The transmission part includes a photoplethysmography(PPG) sensor for detecting pulse wave signals, accelerometer for detecting kinetic signals, and a wireless controller for transmitting acquired bio-information. The receiving part is designed to check and process transmitted data through interoperation with a PC. In the experiments, we collected data during a sitting posture and repeated sit-to-stand motion in laboratory environment, and analyzed the data. As to accuracy, the correlation between the peak-to-peak intervals in the signals of the Biopac equipment and the developed device measured in a sitting posture was 97.5%, and that measured in sit-to-stand motion was 87%. In addition, when bio-signals were transmitted through wireless communication, the transmission was successful 100% without any error. When pulse wave signals and kinetic signals were obtained and compared, the results proved the accuracy and daily applicability of the developed device, and the glass-type wireless bio-signal transmission system is expected to be applicable to unobtrusive health monitoring for the user.

  15. Prediction of sea ice thickness cluster in the Northern Hemisphere

    NASA Astrophysics Data System (ADS)

    Fuckar, Neven-Stjepan; Guemas, Virginie; Johnson, Nathaniel; Doblas-Reyes, Francisco

    2016-04-01

    Sea ice thickness (SIT) has a potential to contain substantial climate memory and predictability in the northern hemisphere (NH) sea ice system. We use 5-member NH SIT, reconstructed with an ocean-sea-ice general circulation model (NEMOv3.3 with LIM2) with a simple data assimilation routine, to determine NH SIT modes of variability disentangled from the long-term climate change. Specifically, we apply the K-means cluster analysis - one of nonhierarchical clustering methods that partition data into modes or clusters based on their distances in the physical - to determine optimal number of NH SIT clusters (K=3) and their historical variability. To examine prediction skill of NH SIT clusters in EC-Earth2.3, a state-of-the-art coupled climate forecast system, we use 5-member ocean and sea ice initial conditions (IC) from the same ocean-sea-ice historical reconstruction and atmospheric IC from ERA-Interim reanalysis. We focus on May 1st and Nov 1st start dates from 1979 to 2010. Common skill metrics of probability forecast, such as rank probability skill core and ROC (relative operating characteristics - hit rate versus false alarm rate) and reliability diagrams show that our dynamical model predominately perform better than the 1st order Marko chain forecast (that beats climatological forecast) over the first forecast year. On average May 1st start dates initially have lower skill than Nov 1st start dates, but their skill is degraded at slower rate than skill of forecast started on Nov 1st.

  16. Posture And Dorsal Shape At A Sitted Workstation

    NASA Astrophysics Data System (ADS)

    Lepoutre, F. X.; Cloup, P.; Guerra, T. M.

    1986-07-01

    The ergonomic analysis of a control or a supervision workstation for a vehicle or a process, necessitates to take into account the biomecanical visuo-postural system. The measurements, which are necessary to do, must give informations about the spatial direction of the limbs, the dorsal shape, eventually the eyes direction, and the postural evolution during the working time. More, the smallness of the work station, the backrest and sometime a vibratory environment made use specific, strong and small devices wich do not disturb the operator. The measurement system which we propose is made of an optical device. This system is studied in relation with the french "Institute de Recherche pour les Transports" for an ergonomic analysis of a truck cabin. The optical device consists on placing on the body of the driver on particular places materializing specially members and trunck joint points, some drops which reflect the infra-red raies coming from a specific light. Several cameras whose relative positions depend on the experiment site, transmit video signals to the associated treatment systems which extract the coordinates (Xi, Yi) of each drop in the observation scope of any camera. By regrouping the informations obtained from every view, it is possible to obtain the spatial drop position and then to restore the individual's posture in three dimensions. Therefore, this device doesn't enable us, in consideration of the backrest, to analyse the dorsal posture, which is important with regard to dorsal pains frequency. For that reason, we complete the measurements by using a "curvometer". This device consists of a flexible stick fixed upon the individual back with elastic belts, whose distorsions (curvature in m-1) are measured, in the individual's sagittal plane, with 4 strain gauges pairs; located approximately at the level of vertebra D1, D6, D10 and L3. A fifth measurement, concerning the inclination (in degree) of the lower part of the stick, makes it is possible to represent at any time the dorsal shape in the space. Some examples of real postures, measured by these complementary electromecanic and video devices, will be presented.

  17. In-Situ Cameras for Radiometric Correction of Remotely Sensed Data

    NASA Astrophysics Data System (ADS)

    Kautz, Jess S.

    The atmosphere distorts the spectrum of remotely sensed data, negatively affecting all forms of investigating Earth's surface. To gather reliable data, it is vital that atmospheric corrections are accurate. The current state of the field of atmospheric correction does not account well for the benefits and costs of different correction algorithms. Ground spectral data are required to evaluate these algorithms better. This dissertation explores using cameras as radiometers as a means of gathering ground spectral data. I introduce techniques to implement a camera systems for atmospheric correction using off the shelf parts. To aid the design of future camera systems for radiometric correction, methods for estimating the system error prior to construction, calibration and testing of the resulting camera system are explored. Simulations are used to investigate the relationship between the reflectance accuracy of the camera system and the quality of atmospheric correction. In the design phase, read noise and filter choice are found to be the strongest sources of system error. I explain the calibration methods for the camera system, showing the problems of pixel to angle calibration, and adapting the web camera for scientific work. The camera system is tested in the field to estimate its ability to recover directional reflectance from BRF data. I estimate the error in the system due to the experimental set up, then explore how the system error changes with different cameras, environmental set-ups and inversions. With these experiments, I learn about the importance of the dynamic range of the camera, and the input ranges used for the PROSAIL inversion. Evidence that the camera can perform within the specification set for ELM correction in this dissertation is evaluated. The analysis is concluded by simulating an ELM correction of a scene using various numbers of calibration targets, and levels of system error, to find the number of cameras needed for a full-scale implementation.

  18. Harpicon camera for HDTV

    NASA Astrophysics Data System (ADS)

    Tanada, Jun

    1992-08-01

    Ikegami has been involved in broadcast equipment ever since it was established as a company. In conjunction with NHK it has brought forth countless television cameras, from black-and-white cameras to color cameras, HDTV cameras, and special-purpose cameras. In the early days of HDTV (high-definition television, also known as "High Vision") cameras the specifications were different from those for the cameras of the present-day system, and cameras using all kinds of components, having different arrangements of components, and having different appearances were developed into products, with time spent on experimentation, design, fabrication, adjustment, and inspection. But recently the knowhow built up thus far in components, , printed circuit boards, and wiring methods has been incorporated in camera fabrication, making it possible to make HDTV cameras by metbods similar to the present system. In addition, more-efficient production, lower costs, and better after-sales service are being achieved by using the same circuits, components, mechanism parts, and software for both HDTV cameras and cameras that operate by the present system.

  19. Discrete physiological effects of beetroot juice and potassium nitrate supplementation following 4-wk sprint interval training.

    PubMed

    Thompson, Christopher; Vanhatalo, Anni; Kadach, Stefan; Wylie, Lee J; Fulford, Jonathan; Ferguson, Scott K; Blackwell, Jamie R; Bailey, Stephen J; Jones, Andrew M

    2018-06-01

    The physiological and exercise performance adaptations to sprint interval training (SIT) may be modified by dietary nitrate ([Formula: see text]) supplementation. However, it is possible that different types of [Formula: see text] supplementation evoke divergent physiological and performance adaptations to SIT. The purpose of this study was to compare the effects of 4-wk SIT with and without concurrent dietary [Formula: see text] supplementation administered as either [Formula: see text]-rich beetroot juice (BR) or potassium [Formula: see text] (KNO 3 ). Thirty recreationally active subjects completed a battery of exercise tests before and after a 4-wk intervention in which they were allocated to one of three groups: 1) SIT undertaken without dietary [Formula: see text] supplementation (SIT); 2) SIT accompanied by concurrent BR supplementation (SIT + BR); or 3) SIT accompanied by concurrent KNO 3 supplementation (SIT + KNO 3 ). During severe-intensity exercise, V̇o 2peak and time to task failure were improved to a greater extent with SIT + BR than SIT and SIT + KNO 3 ( P < 0.05). There was also a greater reduction in the accumulation of muscle lactate at 3 min of severe-intensity exercise in SIT + BR compared with SIT + KNO 3 ( P < 0.05). Plasma [Formula: see text] concentration fell to a greater extent during severe-intensity exercise in SIT + BR compared with SIT and SIT + KNO 3 ( P < 0.05). There were no differences between groups in the reduction in the muscle phosphocreatine recovery time constant from pre- to postintervention ( P > 0.05). These findings indicate that 4-wk SIT with concurrent BR supplementation results in greater exercise capacity adaptations compared with SIT alone and SIT with concurrent KNO 3 supplementation. This may be the result of greater NO-mediated signaling in SIT + BR compared with SIT + KNO 3 . NEW & NOTEWORTHY We compared the influence of different forms of dietary nitrate supplementation on the physiological and performance adaptations to sprint interval training (SIT). Compared with SIT alone, supplementation with nitrate-rich beetroot juice, but not potassium [Formula: see text], enhanced some physiological adaptations to training.

  20. An attentive multi-camera system

    NASA Astrophysics Data System (ADS)

    Napoletano, Paolo; Tisato, Francesco

    2014-03-01

    Intelligent multi-camera systems that integrate computer vision algorithms are not error free, and thus both false positive and negative detections need to be revised by a specialized human operator. Traditional multi-camera systems usually include a control center with a wall of monitors displaying videos from each camera of the network. Nevertheless, as the number of cameras increases, switching from a camera to another becomes hard for a human operator. In this work we propose a new method that dynamically selects and displays the content of a video camera from all the available contents in the multi-camera system. The proposed method is based on a computational model of human visual attention that integrates top-down and bottom-up cues. We believe that this is the first work that tries to use a model of human visual attention for the dynamic selection of the camera view of a multi-camera system. The proposed method has been experimented in a given scenario and has demonstrated its effectiveness with respect to the other methods and manually generated ground-truth. The effectiveness has been evaluated in terms of number of correct best-views generated by the method with respect to the camera views manually generated by a human operator.

  1. Associations of office workers' objectively assessed occupational sitting, standing and stepping time with musculoskeletal symptoms.

    PubMed

    Coenen, Pieter; Healy, Genevieve N; Winkler, Elisabeth A H; Dunstan, David W; Owen, Neville; Moodie, Marj; LaMontagne, Anthony D; Eakin, Elizabeth A; O'Sullivan, Peter B; Straker, Leon M

    2018-04-22

    We examined the association of musculoskeletal symptoms (MSS) with workplace sitting, standing and stepping time, as well as sitting and standing time accumulation (i.e. usual bout duration of these activities), measured objectively with the activPAL3 monitor. Using baseline data from the Stand Up Victoria trial (216 office workers, 14 workplaces), cross-sectional associations of occupational activities with self-reported MSS (low-back, upper and lower extremity symptoms in the last three months) were examined using probit regression, correcting for clustering and adjusting for confounders. Sitting bout duration was significantly (p < 0.05) associated, non-linearly, with MSS, such that those in the middle tertile displayed the highest prevalence of upper extremity symptoms. Other associations were non-significant but sometimes involved large differences in symptom prevalence (e.g. 38%) by activity. Though causation is unclear, these non-linear associations suggest that sitting and its alternatives (i.e. standing and stepping) interact with MSS and this should be considered when designing safe work systems. Practitioner summary: We studied associations of objectively assessed occupational activities with musculoskeletal symptoms in office workers. Workers who accumulated longer sitting bouts reported fewer upper extremity symptoms. Total activity duration was not significantly associated with musculoskeletal symptoms. We underline the importance of considering total volumes and patterns of activity time in musculoskeletal research.

  2. Credit WCT. Photographic copy of photograph, view looking northeast down ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit WCT. Photographic copy of photograph, view looking northeast down onto new Dd test station from Test Stand "D" tower. Hatch of Dd test cell is open, and a test engine sits on a dolly nearby awaiting mounting. Note the water-cooled diffuser on the east end of the test chamber; this was soon replaced with a new diffuser and a steam-driven ejector for simulated high-altitude tests. A closed circuit television camera is mounted on the west end of the test cell. At the lower left of the view are fuel and oxidizer run tanks which supply propellants for test runs. (JPL negative no. 384-2650-A, 8 February 1961) - Jet Propulsion Laboratory Edwards Facility, Test Stand D, Edwards Air Force Base, Boron, Kern County, CA

  3. Prism-based single-camera system for stereo display

    NASA Astrophysics Data System (ADS)

    Zhao, Yue; Cui, Xiaoyu; Wang, Zhiguo; Chen, Hongsheng; Fan, Heyu; Wu, Teresa

    2016-06-01

    This paper combines the prism and single camera and puts forward a method of stereo imaging with low cost. First of all, according to the principle of geometrical optics, we can deduce the relationship between the prism single-camera system and dual-camera system, and according to the principle of binocular vision we can deduce the relationship between binoculars and dual camera. Thus we can establish the relationship between the prism single-camera system and binoculars and get the positional relation of prism, camera, and object with the best effect of stereo display. Finally, using the active shutter stereo glasses of NVIDIA Company, we can realize the three-dimensional (3-D) display of the object. The experimental results show that the proposed approach can make use of the prism single-camera system to simulate the various observation manners of eyes. The stereo imaging system, which is designed by the method proposed by this paper, can restore the 3-D shape of the object being photographed factually.

  4. Sitting Time in Adults 65 Years and Over: Behavior, Knowledge, and Intentions to Change.

    PubMed

    Alley, Stephanie; van Uffelen, Jannique G Z; Duncan, Mitch J; De Cocker, Katrien; Schoeppe, Stephanie; Rebar, Amanda L; Vandelanotte, Corneel

    2018-04-01

    This study examined sitting time, knowledge, and intentions to change sitting time in older adults. An online survey was completed by 494 Australians aged 65+. Average daily sitting was high (9.0 hr). Daily sitting time was the highest during TV (3.3 hr), computer (2.1 hr), and leisure (1.7 hr). A regression analysis demonstrated that women were more knowledgeable about the health risks of sitting compared to men. The percentage of older adults intending to sit less were the highest for TV (24%), leisure (24%), and computer (19%) sitting time. Regression analyses demonstrated that intentions varied by gender (for TV sitting), education (leisure and work sitting), body mass index (computer, leisure, and transport sitting), and physical activity (TV, computer, and leisure sitting). Interventions should target older adults' TV, computer, and leisure time sitting, with a focus on intentions in older males and older adults with low education, those who are active, and those with a normal weight.

  5. Feasibility evaluation and study of adapting the attitude reference system to the Orbiter camera payload system's large format camera

    NASA Technical Reports Server (NTRS)

    1982-01-01

    A design concept that will implement a mapping capability for the Orbital Camera Payload System (OCPS) when ground control points are not available is discussed. Through the use of stellar imagery collected by a pair of cameras whose optical axis are structurally related to the large format camera optical axis, such pointing information is made available.

  6. Traffic Sign Recognition with Invariance to Lighting in Dual-Focal Active Camera System

    NASA Astrophysics Data System (ADS)

    Gu, Yanlei; Panahpour Tehrani, Mehrdad; Yendo, Tomohiro; Fujii, Toshiaki; Tanimoto, Masayuki

    In this paper, we present an automatic vision-based traffic sign recognition system, which can detect and classify traffic signs at long distance under different lighting conditions. To realize this purpose, the traffic sign recognition is developed in an originally proposed dual-focal active camera system. In this system, a telephoto camera is equipped as an assistant of a wide angle camera. The telephoto camera can capture a high accuracy image for an object of interest in the view field of the wide angle camera. The image from the telephoto camera provides enough information for recognition when the accuracy of traffic sign is low from the wide angle camera. In the proposed system, the traffic sign detection and classification are processed separately for different images from the wide angle camera and telephoto camera. Besides, in order to detect traffic sign from complex background in different lighting conditions, we propose a type of color transformation which is invariant to light changing. This color transformation is conducted to highlight the pattern of traffic signs by reducing the complexity of background. Based on the color transformation, a multi-resolution detector with cascade mode is trained and used to locate traffic signs at low resolution in the image from the wide angle camera. After detection, the system actively captures a high accuracy image of each detected traffic sign by controlling the direction and exposure time of the telephoto camera based on the information from the wide angle camera. Moreover, in classification, a hierarchical classifier is constructed and used to recognize the detected traffic signs in the high accuracy image from the telephoto camera. Finally, based on the proposed system, a set of experiments in the domain of traffic sign recognition is presented. The experimental results demonstrate that the proposed system can effectively recognize traffic signs at low resolution in different lighting conditions.

  7. A comparison of trunk biomechanics, musculoskeletal discomfort and productivity during simulated sit-stand office work.

    PubMed

    Karakolis, Thomas; Barrett, Jeff; Callaghan, Jack P

    2016-10-01

    Sedentary office work has been shown to cause low back discomfort and potentially cause injury. Prolonged standing work has been shown to cause discomfort. The implementation of a sit-stand paradigm is hypothesised to mitigate discomfort and prevent injury induced by prolonged exposure to each posture in isolation. This study explored the potential of sit-stand to reduce discomfort and prevent injury, without adversely affecting productivity. Twenty-four participants performed simulated office work in three different conditions: sitting, standing and sit-stand. Variables measured included: perceived discomfort, L4-L5 joint loading and typing/mousing productivity. Working in a sit-stand paradigm was found to have the potential to reduce discomfort when compared to working in a sitting or standing only configuration. Sit-stand was found to be associated with reduced lumbar flexion during sitting compared to sitting only. Increasing lumbar flexion during prolonged sitting is a known injury mechanism. Therefore, sit-stand exhibited a potentially beneficial response of reduced lumbar flexion that could have the potential to prevent injury. Sit-stand had no significant effect on productivity. Practitioner Summary: This study has contributed foundational elements to guide usage recommendations for sit-stand workstations. The sit-stand paradigm can reduce discomfort; however, working in a sit-stand ratio of 15:5 min may not be the most effective ratio. More frequent posture switches may be necessary to realise the full benefit of sit-stand.

  8. Are we chained to our desks? Describing desk-based sitting using a novel measure of occupational sitting.

    PubMed

    Ryde, Gemma Cathrine; Brown, Helen Elizabeth; Gilson, Nicholas David; Brown, Wendy J

    2014-09-01

    Prolonged occupational sitting is related to poor health outcomes. Detailed data on sitting time at desks are required to understand and effectively influence occupational sitting habits. Full-time office employees were recruited (n = 105; mean age 40.9 ± 11.5 years; BMI 26.1 ± 3.9, 65% women). Sitting at the desk and in other work contexts was measured using a sitting pad and ActivPAL for an entire working week. Employees used a diary to record work hours. Time spent at work, sitting at work and at the desk; number of sit to stand transitions at the desk; and number of bouts of continuous sitting at the desk < 20 and > 60 minutes, were calculated. Average time spent at work was 8.7 ± 0.8 hours/day with 67% spent sitting at the desk (5.8 ± 1.2 hours/day), and 4% in other workplace settings. On average, employees got up from their desks 3 times/hour (29 ± 13/day). Sitting for more than 60 consecutive minutes occurred infrequently (0.69 ± 0.62 times/day), with most sit to stands (80%; 23 ± 14) occurring before 20 minutes of continual sitting. The findings provide highly detailed insights into desk-based sitting habits, highlighting large proportions of time spent sitting at desks, but with frequent interruptions.

  9. Hubble peeks at a spiral galaxy

    NASA Image and Video Library

    2015-07-10

    This little-known galaxy, officially named J04542829-6625280, but most often referred to as LEDA 89996, is a classic example of a spiral galaxy. The galaxy is much like our own galaxy, the Milky Way. The disk-shaped galaxy is seen face on, revealing the winding structure of the spiral arms. Dark patches in these spiral arms are in fact dust and gas — the raw materials for new stars. The many young stars that form in these regions make the spiral arms appear bright and bluish. The galaxy sits in a vibrant area of the night sky within the constellation of Dorado (The Swordfish), and appears very close to the Large Magellanic Cloud — one of the satellite galaxies of the Milky Way. The observations were carried out with the high resolution channel of Hubble’s Advanced Camera for Surveys. Image credit: ESA/Hubble & NASA, Acknowledgement: Flickr user C. Claude NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  10. Middle Range Sea Ice Prediction System of Voyage Environmental Information System in Arctic Sea Route

    NASA Astrophysics Data System (ADS)

    Lim, H. S.

    2017-12-01

    Due to global warming, the sea ice in the Arctic Ocean is melting dramatically in summer, which is providing a new opportunity to exploit the Northern Sea Route (NSR) connecting Asia and Europe ship route. Recent increases in logistics transportation through NSR and resource development reveal the possible threats of marine pollution and marine transportation accidents without real-time navigation system. To develop a safe Voyage Environmental Information System (VEIS) for vessels operating, the Korea Institute of Ocean Science and Technology (KIOST) which is supported by the Ministry of Oceans and Fisheries, Korea has initiated the development of short-term and middle range prediction system for the sea ice concentration (SIC) and sea ice thickness (SIT) in NSR since 2014. The sea ice prediction system of VEIS consists of AMSR2 satellite composite images (a day), short-term (a week) prediction system, and middle range (a month) prediction system using a statistical method with re-analysis data (TOPAZ) and short-term predicted model data. In this study, the middle range prediction system for the SIC and SIT in NSR is calibrated with another middle range predicted atmospheric and oceanic data (NOAA CFSv2). The system predicts one month SIC and SIT on a daily basis, as validated with dynamic composite SIC data extracted from AMSR2 L2 satellite images.

  11. How Does Definition of Minimum Break Length Affect Objective Measures of Sitting Outcomes Among Office Workers?

    PubMed

    Kloster, Stine; Danquah, Ida Høgstedt; Holtermann, Andreas; Aadahl, Mette; Tolstrup, Janne Schurmann

    2017-01-01

    Harmful health effects associated with sedentary behavior may be attenuated by breaking up long periods of sitting by standing or walking. However, studies assess interruptions in sitting time differently, making comparisons between studies difficult. It has not previously been described how the definition of minimum break duration affects sitting outcomes. Therefore, the aim was to address how definitions of break length affect total sitting time, number of sit-to-stand transitions, prolonged sitting periods and time accumulated in prolonged sitting periods among office workers. Data were collected from 317 office workers. Thigh position was assessed with an ActiGraph GT3X+ fixed on the right thigh. Data were exported with varying bout length of breaks. Afterward, sitting outcomes were calculated for the respective break lengths. Absolute numbers of sit-to-stand transitions decreased, and number of prolonged sitting periods and total time accumulated in prolonged sitting periods increased, with increasing minimum break length. Total sitting time was not influenced by varying break length. The definition of minimum break length influenced the sitting outcomes with the exception of total sitting time. A standard definition of break length is needed for comparison and interpretation of studies in the evolving research field of sedentary behavior.

  12. Structure-From for Calibration of a Vehicle Camera System with Non-Overlapping Fields-Of in AN Urban Environment

    NASA Astrophysics Data System (ADS)

    Hanel, A.; Stilla, U.

    2017-05-01

    Vehicle environment cameras observing traffic participants in the area around a car and interior cameras observing the car driver are important data sources for driver intention recognition algorithms. To combine information from both camera groups, a camera system calibration can be performed. Typically, there is no overlapping field-of-view between environment and interior cameras. Often no marked reference points are available in environments, which are a large enough to cover a car for the system calibration. In this contribution, a calibration method for a vehicle camera system with non-overlapping camera groups in an urban environment is described. A-priori images of an urban calibration environment taken with an external camera are processed with the structure-frommotion method to obtain an environment point cloud. Images of the vehicle interior, taken also with an external camera, are processed to obtain an interior point cloud. Both point clouds are tied to each other with images of both image sets showing the same real-world objects. The point clouds are transformed into a self-defined vehicle coordinate system describing the vehicle movement. On demand, videos can be recorded with the vehicle cameras in a calibration drive. Poses of vehicle environment cameras and interior cameras are estimated separately using ground control points from the respective point cloud. All poses of a vehicle camera estimated for different video frames are optimized in a bundle adjustment. In an experiment, a point cloud is created from images of an underground car park, as well as a point cloud of the interior of a Volkswagen test car is created. Videos of two environment and one interior cameras are recorded. Results show, that the vehicle camera poses are estimated successfully especially when the car is not moving. Position standard deviations in the centimeter range can be achieved for all vehicle cameras. Relative distances between the vehicle cameras deviate between one and ten centimeters from tachymeter reference measurements.

  13. Relative and Absolute Calibration of a Multihead Camera System with Oblique and Nadir Looking Cameras for a Uas

    NASA Astrophysics Data System (ADS)

    Niemeyer, F.; Schima, R.; Grenzdörffer, G.

    2013-08-01

    Numerous unmanned aerial systems (UAS) are currently flooding the market. For the most diverse applications UAVs are special designed and used. Micro and mini UAS (maximum take-off weight up to 5 kg) are of particular interest, because legal restrictions are still manageable but also the payload capacities are sufficient for many imaging sensors. Currently a camera system with four oblique and one nadir looking cameras is under development at the Chair for Geodesy and Geoinformatics. The so-called "Four Vision" camera system was successfully built and tested in the air. A MD4-1000 UAS from microdrones is used as a carrier system. Light weight industrial cameras are used and controlled by a central computer. For further photogrammetric image processing, each individual camera, as well as all the cameras together have to be calibrated. This paper focuses on the determination of the relative orientation between the cameras with the „Australis" software and will give an overview of the results and experiences of test flights.

  14. Compact Autonomous Hemispheric Vision System

    NASA Technical Reports Server (NTRS)

    Pingree, Paula J.; Cunningham, Thomas J.; Werne, Thomas A.; Eastwood, Michael L.; Walch, Marc J.; Staehle, Robert L.

    2012-01-01

    Solar System Exploration camera implementations to date have involved either single cameras with wide field-of-view (FOV) and consequently coarser spatial resolution, cameras on a movable mast, or single cameras necessitating rotation of the host vehicle to afford visibility outside a relatively narrow FOV. These cameras require detailed commanding from the ground or separate onboard computers to operate properly, and are incapable of making decisions based on image content that control pointing and downlink strategy. For color, a filter wheel having selectable positions was often added, which added moving parts, size, mass, power, and reduced reliability. A system was developed based on a general-purpose miniature visible-light camera using advanced CMOS (complementary metal oxide semiconductor) imager technology. The baseline camera has a 92 FOV and six cameras are arranged in an angled-up carousel fashion, with FOV overlaps such that the system has a 360 FOV (azimuth). A seventh camera, also with a FOV of 92 , is installed normal to the plane of the other 6 cameras giving the system a > 90 FOV in elevation and completing the hemispheric vision system. A central unit houses the common electronics box (CEB) controlling the system (power conversion, data processing, memory, and control software). Stereo is achieved by adding a second system on a baseline, and color is achieved by stacking two more systems (for a total of three, each system equipped with its own filter.) Two connectors on the bottom of the CEB provide a connection to a carrier (rover, spacecraft, balloon, etc.) for telemetry, commands, and power. This system has no moving parts. The system's onboard software (SW) supports autonomous operations such as pattern recognition and tracking.

  15. What Do Older People Do When Sitting and Why? Implications for Decreasing Sedentary Behavior.

    PubMed

    Palmer, Victoria J; Gray, Cindy M; Fitzsimons, Claire F; Mutrie, Nanette; Wyke, Sally; Deary, Ian J; Der, Geoff; Chastin, Sebastien F M; Skelton, Dawn A

    2018-05-15

    Sitting less can reduce older adults' risk of ill health and disability. Effective sedentary behavior interventions require greater understanding of what older adults do when sitting (and not sitting), and why. This study compares the types, context, and role of sitting activities in the daily lives of older men and women who sit more or less than average. Semistructured interviews with 44 older men and women of different ages, socioeconomic status, and objectively measured sedentary behavior were analyzed using social practice theory to explore the multifactorial, inter-relational influences on their sedentary behavior. Thematic frameworks facilitated between-group comparisons. Older adults described many different leisure time, household, transport, and occupational sitting and non-sitting activities. Leisure-time sitting in the home (e.g., watching TV) was most common, but many non-sitting activities, including "pottering" doing household chores, also took place at home. Other people and access to leisure facilities were associated with lower sedentary behavior. The distinction between being busy/not busy was more important to most participants than sitting/not sitting, and informed their judgments about high-value "purposeful" (social, cognitively active, restorative) sitting and low-value "passive" sitting. Declining physical function contributed to temporal sitting patterns that did not vary much from day-to-day. Sitting is associated with cognitive, social, and/or restorative benefits, embedded within older adults' daily routines, and therefore difficult to change. Useful strategies include supporting older adults to engage with other people and local facilities outside the home, and break up periods of passive sitting at home.

  16. The research of adaptive-exposure on spot-detecting camera in ATP system

    NASA Astrophysics Data System (ADS)

    Qian, Feng; Jia, Jian-jun; Zhang, Liang; Wang, Jian-Yu

    2013-08-01

    High precision acquisition, tracking, pointing (ATP) system is one of the key techniques of laser communication. The spot-detecting camera is used to detect the direction of beacon in laser communication link, so that it can get the position information of communication terminal for ATP system. The positioning accuracy of camera decides the capability of laser communication system directly. So the spot-detecting camera in satellite-to-earth laser communication ATP systems needs high precision on target detection. The positioning accuracy of cameras should be better than +/-1μ rad . The spot-detecting cameras usually adopt centroid algorithm to get the position information of light spot on detectors. When the intensity of beacon is moderate, calculation results of centroid algorithm will be precise. But the intensity of beacon changes greatly during communication for distance, atmospheric scintillation, weather etc. The output signal of detector will be insufficient when the camera underexposes to beacon because of low light intensity. On the other hand, the output signal of detector will be saturated when the camera overexposes to beacon because of high light intensity. The calculation accuracy of centroid algorithm becomes worse if the spot-detecting camera underexposes or overexposes, and then the positioning accuracy of camera will be reduced obviously. In order to improve the accuracy, space-based cameras should regulate exposure time in real time according to light intensity. The algorithm of adaptive-exposure technique for spot-detecting camera based on metal-oxide-semiconductor (CMOS) detector is analyzed. According to analytic results, a CMOS camera in space-based laser communication system is described, which utilizes the algorithm of adaptive-exposure to adapting exposure time. Test results from imaging experiment system formed verify the design. Experimental results prove that this design can restrain the reduction of positioning accuracy for the change of light intensity. So the camera can keep stable and high positioning accuracy during communication.

  17. Mobile Phone Use Behaviors and Postures on Public Transportation Systems.

    PubMed

    Liang, Huey-Wen; Hwang, Yaw-Huei

    2016-01-01

    Mobile phones are common in our daily life, but the users' preferences for postures or screen operating styles have not been studied. This was a cross-sectional and observational study. We randomly sampled passengers who used mobile phones on the Mass Rapid Transit (MRT) system in metropolitan Taipei. A checklist was used to observe their body postures and screen operating styles while sitting or standing. As a result, 1,230 subjects from 400 trips were observed. Overall, of all the passengers who were sitting, 41% of them were using mobile phones. The majority of the tasks involved browsing (84%) with their phones in a portrait orientation (93%). Different-hand holding/operating was the most commonly used operating style while sitting (46%) and same-hand holding/operating was the most common while standing (46%). The distribution of screen operating styles was significantly different for those sitting than for those standing and for different genders and age groups. The most frequently observed postures while sitting were having one's trunk against a backrest, feet on the floor and with or without an arm supported (58%). As for the users who were standing, the both- and different-hands groups had a high proportion of arms unsupported, feet on the floor and either their trunk supported or not. In contrast, the same-hand group tended to have their trunk unsupported, were holding a pole or handstrap and had both feet on floor. Further studies are warranted to characterize the ergonomic exposure of these commonly used postures and operating styles, and our results will help guide the selection of experimental conditions for laboratory settings.

  18. Electrostatic camera system functional design study

    NASA Technical Reports Server (NTRS)

    Botticelli, R. A.; Cook, F. J.; Moore, R. F.

    1972-01-01

    A functional design study for an electrostatic camera system for application to planetary missions is presented. The electrostatic camera can produce and store a large number of pictures and provide for transmission of the stored information at arbitrary times after exposure. Preliminary configuration drawings and circuit diagrams for the system are illustrated. The camera system's size, weight, power consumption, and performance are characterized. Tradeoffs between system weight, power, and storage capacity are identified.

  19. Sit-to-Stand Movement in Children with Hemiplegic Cerebral Palsy: Relationship with Knee Extensor Torque and Social Participation

    ERIC Educational Resources Information Center

    dos Santos, Adriana Neves; Pavao, Silvia Leticia; Santiago, Paulo Roberto Pereira; Salvini, Tania de Fatima; Rocha, Nelci Adriana Cicuto Ferreira

    2013-01-01

    This study aimed to investigate the relationship between sit-to-stand (STS) movement, knee extensor torque and social participation in children with cerebral palsy (CP). Seven spastic hemiplegic CP patients (8.0 plus or minus 2.2 years), classified by the Gross Motor Function Classification System as I and II, and 18 typical children (8.4 plus or…

  20. Socio-demographic, behavioural and cognitive correlates of work-related sitting time in German men and women.

    PubMed

    Wallmann-Sperlich, Birgit; Bucksch, Jens; Schneider, Sven; Froboese, Ingo

    2014-12-11

    Sitting time is ubiquitous for most adults in developed countries and is most prevalent in three domains: in the workplace, during transport and during leisure time. The correlates of prolonged sitting time in workplace settings are not well understood. Therefore, the aim of this study was to examine the gender-specific associations between the socio-demographic, behavioural and cognitive correlates of work-related sitting time. A cross-sectional sample of working German adults (n = 1515; 747 men; 43.5 ± 11.0 years) completed questionnaires regarding domain-specific sitting times and physical activity (PA) and answered statements concerning beliefs about sitting. To identify gender-specific correlates of work-related sitting time, we used a series of linear regressions. The overall median was 2 hours of work-related sitting time/day. Regression analyses showed for men (β = -.43) and for women (β = -.32) that work-related PA was negatively associated with work-related sitting time, but leisure-related PA was not a significant correlate. For women only, transport-related PA (β = -.07) was a negative correlate of work-related sitting time, suggesting increased sitting times during work with decreased PA in transport. Education and income levels were positively associated, and in women only, age (β = -.14) had a negative correlation with work-related sitting time. For both genders, TV-related sitting time was negatively associated with work-related sitting time. The only association with cognitive correlates was found in men for the belief 'Sitting for long periods does not matter to me' (β = .10) expressing a more positive attitude towards sitting with increasing sitting durations. The present findings show that in particular, higher educated men and women as well as young women are high-risk groups to target for reducing prolonged work-related sitting time. In addition, our findings propose considering increasing transport-related PA, especially in women, as well as promoting recreation-related PA in conjunction with efforts to reduce long work-related sitting times.

  1. [Specific immunotherapy. Hyposensitization with allergens].

    PubMed

    Wedi, B; Kapp, A

    2004-04-01

    Successful allergen-specific immunotherapy (SIT) induces complex immunologic chan-ges resulting in reduced allergic inflammatory reactions. SIT has long-term effects in mild forms of inhalant allergies and is effective even when standard pharmacotherapy fails. Moreover, the risk to develop additional allergic sensitizations and the development of asthma is significantly reduced in children with allergic rhinitis. SIT is the treatment of choice in patients with systemic reactions to hymenoptera venoms. Although the exact effector mechanisms of SIT still have to be clarified, the most probable effect is a modulation of regulatory T cells associated with a switch of allergen-specific B-cells towards IgG4 production. The critical point to insure efficacy and safety is the selection of patients and allergens, task best performed by a specialist trained in allergology. Further details are available in the position papers of the German allergy societies - DGAI(Deutsche Gesellschaft fiir Allergologie und Klinische Immunologie) and ADA (Arzte-verband Deutscher Allergologen) - which can be found at www.dgaki.de.

  2. Perceived body discomfort and trunk muscle activity in three prolonged sitting postures

    PubMed Central

    Waongenngarm, Pooriput; Rajaratnam, Bala S.; Janwantanakul, Prawit

    2015-01-01

    [Purpose] This study aimed to investigate the perceived discomfort and trunk muscle activity in three different 1-hour sitting postures. [Subjects] A repeated-measures design study was conducted on 10 healthy subjects. [Methods] Each subject sat for an hour in three sitting postures (i.e., upright, slumped, and forward leaning sitting postures). Subjects rated perceived body discomfort using Borg’s CR-10 scale at the beginning and after 1 hour sitting. The electromyographic activity of the trunk muscle activity was recorded during the 1-hour period of sitting. [Results] The forward leaning sitting posture led to higher Borg scores in the low back than those in the upright (p = 0.002) and slumped sitting postures (p < 0.001). The forward leaning posture was significantly associated with increased iliocostalis lumborum pars thoracis (ICL) and superficial lumbar multifidus (MF) muscle activity compared with the upright and slumped sitting postures. The upright sitting posture was significantly associated with increased internal oblique (IO)/transversus abdominis (TrA) and ICL muscle activity compared with the slumped sitting posture. [Conclusion] The sitting posture with the highest low back discomfort after prolonged sitting was the forward leaning posture. Sitting in an upright posture is recommended because it increases IO/TrA muscle activation and induces only relatively moderate ICL and MF muscle activation. PMID:26311951

  3. Analysis of sitting forces on stationary chairs for daily activities.

    PubMed

    Hu, Lingling; Tackett, Bob; Tor, Onder; Zhang, Jilei

    2016-04-01

    No literature related to the study of sitting forces on chairs sat on by people who weighed over 136 kg was found. The Business Institutional Furniture Manufactures Association needs force data for development of performance test standards to test chairs for users who weigh up to 181 kg. 20 participants who weighed from 136 to 186 kg completed 6 tasks on an instrumented chair in the sequence of sitting down, remaining seated and rising. Effects of sitting motion, armrest use and seat cushion thickness on vertical sitting forces and centre-of-force were investigated. Results indicated hard sitting down yielded the highest sitting force of 213% in terms of participants' body weights. Armrest use affected sitting forces of normal sitting down, but not of rising and hard sitting down. Cushion thickness affected sitting forces of normal and hard sitting down and shifting, but not of rising, static seating or stretching backward situations. Practitioner Summary: Results of the sitting force and centre-of-force data obtained for this research can help furniture manufacturers develop new product performance test standards for creating reliable engineering design and manufacturing quality and durable products to meet a niche market need.

  4. Autonomic dysfunction affects cerebral neurovascular coupling.

    PubMed

    Azevedo, Elsa; Castro, Pedro; Santos, Rosa; Freitas, João; Coelho, Teresa; Rosengarten, Bernhard; Panerai, Ronney

    2011-12-01

    Autonomic failure (AF) affects the peripheral vascular system, but little is known about its influence on cerebrovascular regulation. Patients with familial amyloidotic polyneuropathy (FAP) were studied as a model for AF. Ten mild (FAPm), 10 severe (FAPs) autonomic dysfunction FAP patients, and 15 healthy controls were monitored in supine and sitting positions for arterial blood pressure (ABP) and heart rate (HR) with arterial volume clamping, and for blood flow velocity (BFV) in posterior (PCA) and contralateral middle cerebral arteries (MCA) with transcranial Doppler. Analysis included resting BFV, cerebrovascular resistance parameters (cerebrovascular resistance index, CVRi; resistance area product, RAP; and critical closing pressure, CrCP), and neurovascular coupling through visually evoked BFV responses in PCA (gain, rate time, attenuation, and natural frequency). In non-stimulation conditions, in each position, there were no significant differences between the groups, regarding HR, BP, resting BFV, and vascular resistance parameters. Sitting ABP was higher than in supine in the three groups, although only significantly in controls. Mean BFV was lower in sitting in all the groups, lacking statistical significance only in FAPs PCA. CVRi and CrCP increased with sitting in all the groups, while RAP increased in controls but decreased in FAPm and FAPs. In visual stimulation conditions, FAPs comparing to controls had a significant decrease of natural frequency, in supine and sitting, and of rate time and gain in sitting position. These results demonstrate that cerebrovascular regulation is affected in FAP subjects with AF, and that it worsens with orthostasis.

  5. Body measurements and the variability of sitting postures at preschool age as preconditions for an optimal adjustment of chairs and tables.

    PubMed

    Voigt, Andrea; Greil, Holle

    2009-03-01

    Preschool age is a biological stage of intensive longitudinal growth with high plasticity of the growing body and of body postures. It is the period where children learn to persist in a sitting posture for a longer time and to use furniture like chairs or other body supporting systems. The growing body shows a special sensitivity for the manifestation of inappropriate postures. In this study the development of body measurements and sitting behaviour of preschool age children is investigated as a precondition for an optimal adjustment of seats and desks to the growing body. Accordingly to the instructions of Knussmann (1988) and Jiirgens (1988) 6 body measurements were taken from 122 German children aged 3 to 7 years from Potsdam, Province Brandenburg. Additionally, every child was videotaped for 10 minutes while crayoning in a sitting position of its own choice using a chair and a desk. To analyse the tapes, the software Noldus Observer was used and examined, picture by picture, to define the different types of sitting postures as well as the duration of persistence in a posture and the number of changes of postures. The used chairs and desks were also measured. Furthermore, the data of the furniture guideline DIN ISO 5970 (DIN, 1981), which regulates the dimensions of furniture for sitting in educational institutions, were compared with the results of the body measurements and with the dimensions of the furniture used by the children.

  6. A Robust Mechanical Sensing System for Unmanned Sea Surface Vehicles

    NASA Technical Reports Server (NTRS)

    Kulczycki, Eric A.; Magnone, Lee J.; Huntsberger, Terrance; Aghazarian, Hrand; Padgett, Curtis W.; Trotz, David C.; Garrett, Michael S.

    2009-01-01

    The need for autonomous navigation and intelligent control of unmanned sea surface vehicles requires a mechanically robust sensing architecture that is watertight, durable, and insensitive to vibration and shock loading. The sensing system developed here comprises four black and white cameras and a single color camera. The cameras are rigidly mounted to a camera bar that can be reconfigured to mount multiple vehicles, and act as both navigational cameras and application cameras. The cameras are housed in watertight casings to protect them and their electronics from moisture and wave splashes. Two of the black and white cameras are positioned to provide lateral vision. They are angled away from the front of the vehicle at horizontal angles to provide ideal fields of view for mapping and autonomous navigation. The other two black and white cameras are positioned at an angle into the color camera's field of view to support vehicle applications. These two cameras provide an overlap, as well as a backup to the front camera. The color camera is positioned directly in the middle of the bar, aimed straight ahead. This system is applicable to any sea-going vehicle, both on Earth and in space.

  7. Head-coupled remote stereoscopic camera system for telepresence applications

    NASA Astrophysics Data System (ADS)

    Bolas, Mark T.; Fisher, Scott S.

    1990-09-01

    The Virtual Environment Workstation Project (VIEW) at NASA's Ames Research Center has developed a remotely controlled stereoscopic camera system that can be used for telepresence research and as a tool to develop and evaluate configurations for head-coupled visual systems associated with space station telerobots and remote manipulation robotic arms. The prototype camera system consists of two lightweight CCD video cameras mounted on a computer controlled platform that provides real-time pan, tilt, and roll control of the camera system in coordination with head position transmitted from the user. This paper provides an overall system description focused on the design and implementation of the camera and platform hardware configuration and the development of control software. Results of preliminary performance evaluations are reported with emphasis on engineering and mechanical design issues and discussion of related psychophysiological effects and objectives.

  8. An integrated port camera and display system for laparoscopy.

    PubMed

    Terry, Benjamin S; Ruppert, Austin D; Steinhaus, Kristen R; Schoen, Jonathan A; Rentschler, Mark E

    2010-05-01

    In this paper, we built and tested the port camera, a novel, inexpensive, portable, and battery-powered laparoscopic tool that integrates the components of a vision system with a cannula port. This new device 1) minimizes the invasiveness of laparoscopic surgery by combining a camera port and tool port; 2) reduces the cost of laparoscopic vision systems by integrating an inexpensive CMOS sensor and LED light source; and 3) enhances laparoscopic surgical procedures by mechanically coupling the camera, tool port, and liquid crystal display (LCD) screen to provide an on-patient visual display. The port camera video system was compared to two laparoscopic video systems: a standard resolution unit from Karl Storz (model 22220130) and a high definition unit from Stryker (model 1188HD). Brightness, contrast, hue, colorfulness, and sharpness were compared. The port camera video is superior to the Storz scope and approximately equivalent to the Stryker scope. An ex vivo study was conducted to measure the operative performance of the port camera. The results suggest that simulated tissue identification and biopsy acquisition with the port camera is as efficient as with a traditional laparoscopic system. The port camera was successfully used by a laparoscopic surgeon for exploratory surgery and liver biopsy during a porcine surgery, demonstrating initial surgical feasibility.

  9. Retinal arteriolar remodeling evaluated with adaptive optics camera: Relationship with blood pressure levels.

    PubMed

    Gallo, A; Mattina, A; Rosenbaum, D; Koch, E; Paques, M; Girerd, X

    2016-06-01

    To research a retinal arterioles wall-to-lumen ratio or lumen diameter cut-off that would discriminate hypertensive from normal subjects using adaptive optics camera. One thousand and five hundred subjects were consecutively recruited and Adaptive Optics Camera rtx1™ (Imagine-Eyes, Orsay, France) was used to measure wall thickness, internal diameter, to calculate wall-to-lumen ratio (WLR) and wall cross-sectional area of retinal arterioles. Sitting office blood pressure was measured once, just before retinal measurements and office blood pressure was defined as systolic blood pressure>=140mmHg and diastolic blood pressure>=90mmHg. ROC curves were constructed to determine cut-off values for retinal parameters to diagnose office hypertension. In another population of 276 subjects office BP, retinal arterioles evaluation and home blood pressure monitoring were obtained. The applicability of retinal WLR or diameter cut-off values were compared in patients with controlled, masked, white-coat and sustained hypertension. In 1500 patients, a WLR>0.31 discriminated office hypertensive subjects with a 0.57 sensitivity and 0.71 specificity. Lumen diameter<78.2μm discriminated office hypertension with a 0.73 sensitivity and a 0.52 specificity. In the other 276 patients, WLR was higher in sustained hypertension vs normotensive patients (0.330±0.06 vs 0.292±0.05; P<0.001) and diameter was narrower in masked hypertensive vs normotensive subjects (73.0±11.2 vs 78.5±11.6μm; P<0.005). A WLR higher than 0.31 is in favour of office arterial hypertension; a diameter under<78μm may indicate a masked hypertension. Retinal arterioles analysis through adaptive optics camera may help the diagnosis of arterial hypertension, in particular in case of masked hypertension. Copyright © 2016. Published by Elsevier SAS.

  10. A real-time camera calibration system based on OpenCV

    NASA Astrophysics Data System (ADS)

    Zhang, Hui; Wang, Hua; Guo, Huinan; Ren, Long; Zhou, Zuofeng

    2015-07-01

    Camera calibration is one of the essential steps in the computer vision research. This paper describes a real-time OpenCV based camera calibration system, and developed and implemented in the VS2008 environment. Experimental results prove that the system to achieve a simple and fast camera calibration, compared with MATLAB, higher precision and does not need manual intervention, and can be widely used in various computer vision system.

  11. Validation of the Microsoft Kinect® camera system for measurement of lower extremity jump landing and squatting kinematics.

    PubMed

    Eltoukhy, Moataz; Kelly, Adam; Kim, Chang-Young; Jun, Hyung-Pil; Campbell, Richard; Kuenze, Christopher

    2016-01-01

    Cost effective, quantifiable assessment of lower extremity movement represents potential improvement over standard tools for evaluation of injury risk. Ten healthy participants completed three trials of a drop jump, overhead squat, and single leg squat task. Peak hip and knee kinematics were assessed using an 8 camera BTS Smart 7000DX motion analysis system and the Microsoft Kinect® camera system. The agreement and consistency between both uncorrected and correct Kinect kinematic variables and the BTS camera system were assessed using interclass correlations coefficients. Peak sagittal plane kinematics measured using the Microsoft Kinect® camera system explained a significant amount of variance [Range(hip) = 43.5-62.8%; Range(knee) = 67.5-89.6%] in peak kinematics measured using the BTS camera system. Across tasks, peak knee flexion angle and peak hip flexion were found to be consistent and in agreement when the Microsoft Kinect® camera system was directly compared to the BTS camera system but these values were improved following application of a corrective factor. The Microsoft Kinect® may not be an appropriate surrogate for traditional motion analysis technology, but it may have potential applications as a real-time feedback tool in pathological or high injury risk populations.

  12. Evaluation of camera-based systems to reduce transit bus side collisions : phase II.

    DOT National Transportation Integrated Search

    2012-12-01

    The sideview camera system has been shown to eliminate blind zones by providing a view to the driver in real time. In : order to provide the best integration of these systems, an integrated camera-mirror system (hybrid system) was : developed and tes...

  13. Real time moving scene holographic camera system

    NASA Technical Reports Server (NTRS)

    Kurtz, R. L. (Inventor)

    1973-01-01

    A holographic motion picture camera system producing resolution of front surface detail is described. The system utilizes a beam of coherent light and means for dividing the beam into a reference beam for direct transmission to a conventional movie camera and two reflection signal beams for transmission to the movie camera by reflection from the front side of a moving scene. The system is arranged so that critical parts of the system are positioned on the foci of a pair of interrelated, mathematically derived ellipses. The camera has the theoretical capability of producing motion picture holograms of projectiles moving at speeds as high as 900,000 cm/sec (about 21,450 mph).

  14. Calibration Techniques for Accurate Measurements by Underwater Camera Systems

    PubMed Central

    Shortis, Mark

    2015-01-01

    Calibration of a camera system is essential to ensure that image measurements result in accurate estimates of locations and dimensions within the object space. In the underwater environment, the calibration must implicitly or explicitly model and compensate for the refractive effects of waterproof housings and the water medium. This paper reviews the different approaches to the calibration of underwater camera systems in theoretical and practical terms. The accuracy, reliability, validation and stability of underwater camera system calibration are also discussed. Samples of results from published reports are provided to demonstrate the range of possible accuracies for the measurements produced by underwater camera systems. PMID:26690172

  15. People Detection by a Mobile Robot Using Stereo Vision in Dynamic Indoor Environments

    NASA Astrophysics Data System (ADS)

    Méndez-Polanco, José Alberto; Muñoz-Meléndez, Angélica; Morales, Eduardo F.

    People detection and tracking is a key issue for social robot design and effective human robot interaction. This paper addresses the problem of detecting people with a mobile robot using a stereo camera. People detection using mobile robots is a difficult task because in real world scenarios it is common to find: unpredictable motion of people, dynamic environments, and different degrees of human body occlusion. Additionally, we cannot expect people to cooperate with the robot to perform its task. In our people detection method, first, an object segmentation method that uses the distance information provided by a stereo camera is used to separate people from the background. The segmentation method proposed in this work takes into account human body proportions to segment people and provides a first estimation of people location. After segmentation, an adaptive contour people model based on people distance to the robot is used to calculate a probability of detecting people. Finally, people are detected merging the probabilities of the contour people model and by evaluating evidence over time by applying a Bayesian scheme. We present experiments on detection of standing and sitting people, as well as people in frontal and side view with a mobile robot in real world scenarios.

  16. A detailed comparison of single-camera light-field PIV and tomographic PIV

    NASA Astrophysics Data System (ADS)

    Shi, Shengxian; Ding, Junfei; Atkinson, Callum; Soria, Julio; New, T. H.

    2018-03-01

    This paper conducts a comprehensive study between the single-camera light-field particle image velocimetry (LF-PIV) and the multi-camera tomographic particle image velocimetry (Tomo-PIV). Simulation studies were first performed using synthetic light-field and tomographic particle images, which extensively examine the difference between these two techniques by varying key parameters such as pixel to microlens ratio (PMR), light-field camera Tomo-camera pixel ratio (LTPR), particle seeding density and tomographic camera number. Simulation results indicate that the single LF-PIV can achieve accuracy consistent with that of multi-camera Tomo-PIV, but requires the use of overall greater number of pixels. Experimental studies were then conducted by simultaneously measuring low-speed jet flow with single-camera LF-PIV and four-camera Tomo-PIV systems. Experiments confirm that given a sufficiently high pixel resolution, a single-camera LF-PIV system can indeed deliver volumetric velocity field measurements for an equivalent field of view with a spatial resolution commensurate with those of multi-camera Tomo-PIV system, enabling accurate 3D measurements in applications where optical access is limited.

  17. Eight cm technology thruster development. [structurally integrated ion thruster for attitude control and stationkeeping of synchronous satellites

    NASA Technical Reports Server (NTRS)

    Hyman, J., Jr.

    1974-01-01

    A structural integrated ion thruster with 8-cm beam diameter (SIT-8) was developed for attitude control and stationkeeping of synchronous satellites. As optimized, the system demonstrates a thrust T=1.14 mlb (not corrected for beam V sub B = 1200 V (I sub sp = 2200 sec) total propellant utilization efficiency nu sub u = 59.8% (is approximately 72% without auxiliary pulse-igniter electrode), and electrical efficiency n sub E 61.9%. The thruster incorporates a wire-mesh anode and tantalum cover surfaces to control discharge chamber flake formation and employs an auxiliary pulse-igniter electrode for hollow-cathode ignition. When the SIT-8 is integrated with the compatible SIT-5 propellant tankage, the system envelope is 35 cm long by 13 cm flange bolt circle with a mass of 9.8 kg including 6.8 kg of mercury propellant. Two thrust vectoring systems which generate beam deflections in two orthogonal directions were also developed under the program and tested with the 8-cm thruster. One system vectors the beam over + or - 10 degrees by gimbaling of the entire thruster (not including tankage), while the other system vectors the beam over + or - 7 degrees by translating the accel electrode relative to the screen electrode.

  18. 836: Developing a Cooperative Communication System for Safe, Effective, and Efficient Patient Care

    DTIC Science & Technology

    2014-01-01

    since tool institution. There was an average rate of 40 positive sepsis identification tool (SIT) triggers per 1000 patient days. In a 6 month...period 28% of patients with a positive SIT had sepsis and 6% had severe sepsis. Interim review showed 67% received first fluid bolus within 20 minutes...for ulcer prevention, including changing the practice of positioning mechanically ventilated and sedated patients , rethinking the use of extended

  19. NASA Testing the Webb Telescope's MIRI Thermal Shield

    NASA Image and Video Library

    2017-12-08

    NASA engineer Acey Herrera recently checked out copper test wires inside the thermal shield of the Mid-Infrared Instrument, known as MIRI, that will fly aboard NASA's James Webb Space Telescope. The shield is designed to protect the vital MIRI instrument from excess heat. At the time of the photo, the thermal shield was about to go through rigorous environmental testing to ensure it can perform properly in the extreme cold temperatures that it will encounter in space. Herrera is working in a thermal vacuum chamber at NASA's Goddard Space Flight Center in Greenbelt, Md. As the MIRI shield lead, Herrera along with a thermal engineer and cryo-engineer verify that the shield is ready for testing. On the Webb telescope, the pioneering camera and spectrometer that comprise the MIRI instrument sit inside the Integrated Science Instrument Module flight structure, that holds Webb's four instruments and their electronic systems during launch and operations. Read more: 1.usa.gov/15I0wrS Credit: NASA/Chris Gunn NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  20. Photogrammetry System and Method for Determining Relative Motion Between Two Bodies

    NASA Technical Reports Server (NTRS)

    Miller, Samuel A. (Inventor); Severance, Kurt (Inventor)

    2014-01-01

    A photogrammetry system and method provide for determining the relative position between two objects. The system utilizes one or more imaging devices, such as high speed cameras, that are mounted on a first body, and three or more photogrammetry targets of a known location on a second body. The system and method can be utilized with cameras having fish-eye, hyperbolic, omnidirectional, or other lenses. The system and method do not require overlapping fields-of-view if two or more cameras are utilized. The system and method derive relative orientation by equally weighting information from an arbitrary number of heterogeneous cameras, all with non-overlapping fields-of-view. Furthermore, the system can make the measurements with arbitrary wide-angle lenses on the cameras.

  1. Stability basin estimates fall risk from observed kinematics, demonstrated on the Sit-to-Stand task.

    PubMed

    Shia, Victor; Moore, Talia Yuki; Holmes, Patrick; Bajcsy, Ruzena; Vasudevan, Ram

    2018-04-27

    The ability to quantitatively measure stability is essential to ensuring the safety of locomoting systems. While the response to perturbation directly reflects the stability of a motion, this experimental method puts human subjects at risk. Unfortunately, existing indirect methods for estimating stability from unperturbed motion have been shown to have limited predictive power. This paper leverages recent advances in dynamical systems theory to accurately estimate the stability of human motion without requiring perturbation. This approach relies on kinematic observations of a nominal Sit-to-Stand motion to construct an individual-specific dynamic model, input bounds, and feedback control that are then used to compute the set of perturbations from which the model can recover. This set, referred to as the stability basin, was computed for 14 individuals, and was able to successfully differentiate between less and more stable Sit-to-Stand strategies for each individual with greater accuracy than existing methods. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Indoor Tracking to Understand Physical Activity and Sedentary Behaviour: Exploratory Study in UK Office Buildings

    PubMed Central

    Spinney, Richard; Smith, Lee; Ucci, Marcella; Fisher, Abigail; Konstantatou, Marina; Sawyer, Alexia; Wardle, Jane; Marmot, Alexi

    2015-01-01

    Little is known of the patterns of physical activity, standing and sitting by office workers. However, insight into these behaviours is of growing interest, notably in regard to public health priorities to reduce non-communicable disease risk factors associated with high levels of sitting time and low levels of physical activity. With the advent and increasing availability of indoor tracking systems it is now becoming possible to build detailed pictures of the usage of indoor spaces. This paper reports initial results of indoor tracking used in conjunction with the ActivPAL activity monitoring device. In this paper we give an overview of the usage of the tracking system and its installation and illustrate some of the resultant data. We also provide preliminary results that investigate the relationship between location, light physical activity and sitting in a small sample of office workers (n=33) from two separate office environments in order to demonstrate the relevance and explanatory power of the technique. PMID:25993515

  3. Advanced imaging system

    NASA Technical Reports Server (NTRS)

    1992-01-01

    This document describes the Advanced Imaging System CCD based camera. The AIS1 camera system was developed at Photometric Ltd. in Tucson, Arizona as part of a Phase 2 SBIR contract No. NAS5-30171 from the NASA/Goddard Space Flight Center in Greenbelt, Maryland. The camera project was undertaken as a part of the Space Telescope Imaging Spectrograph (STIS) project. This document is intended to serve as a complete manual for the use and maintenance of the camera system. All the different parts of the camera hardware and software are discussed and complete schematics and source code listings are provided.

  4. Impact of increasing social media use on sitting time and body mass index.

    PubMed

    Alley, Stephanie; Wellens, Pauline; Schoeppe, Stephanie; de Vries, Hein; Rebar, Amanda L; Short, Camille E; Duncan, Mitch J; Vandelanotte, Corneel

    2017-08-01

    Issue addressed Sedentary behaviours, in particular sitting, increases the risk of cardiovascular disease, type 2 diabetes, obesity and poorer mental health status. In Australia, 70% of adults sit for more than 8h per day. The use of social media applications (e.g. Facebook, Twitter, and Instagram) is on the rise; however, no studies have explored the association of social media use with sitting time and body mass index (BMI). Methods Cross-sectional self-report data on demographics, BMI and sitting time were collected from 1140 participants in the 2013 Queensland Social Survey. Generalised linear models were used to estimate associations of a social media score calculated from social media use, perceived importance of social media, and number of social media contacts with sitting time and BMI. Results Participants with a high social media score had significantly greater sitting times while using a computer in leisure time and significantly greater total sitting time on non-workdays. However, no associations were found between social media score and sitting to view TV, use motorised transport, work or participate in other leisure activities; or total workday, total sitting time or BMI. Conclusions These results indicate that social media use is associated with increased sitting time while using a computer, and total sitting time on non-workdays. So what? The rise in social media use may have a negative impact on health by contributing to computer sitting and total sitting time on non-workdays. Future longitudinal research with a representative sample and objective sitting measures is needed to confirm findings.

  5. A versatile photogrammetric camera automatic calibration suite for multispectral fusion and optical helmet tracking

    NASA Astrophysics Data System (ADS)

    de Villiers, Jason; Jermy, Robert; Nicolls, Fred

    2014-06-01

    This paper presents a system to determine the photogrammetric parameters of a camera. The lens distortion, focal length and camera six degree of freedom (DOF) position are calculated. The system caters for cameras of different sensitivity spectra and fields of view without any mechanical modifications. The distortion characterization, a variant of Brown's classic plumb line method, allows many radial and tangential distortion coefficients and finds the optimal principal point. Typical values are 5 radial and 3 tangential coefficients. These parameters are determined stably and demonstrably produce superior results to low order models despite popular and prevalent misconceptions to the contrary. The system produces coefficients to model both the distorted to undistorted pixel coordinate transformation (e.g. for target designation) and the inverse transformation (e.g. for image stitching and fusion) allowing deterministic rates far exceeding real time. The focal length is determined to minimise the error in absolute photogrammetric positional measurement for both multi camera systems or monocular (e.g. helmet tracker) systems. The system determines the 6 DOF position of the camera in a chosen coordinate system. It can also determine the 6 DOF offset of the camera relative to its mechanical mount. This allows faulty cameras to be replaced without requiring a recalibration of the entire system (such as an aircraft cockpit). Results from two simple applications of the calibration results are presented: stitching and fusion of the images from a dual-band visual/ LWIR camera array, and a simple laboratory optical helmet tracker.

  6. Video systems for real-time oil-spill detection

    NASA Technical Reports Server (NTRS)

    Millard, J. P.; Arvesen, J. C.; Lewis, P. L.; Woolever, G. F.

    1973-01-01

    Three airborne television systems are being developed to evaluate techniques for oil-spill surveillance. These include a conventional TV camera, two cameras operating in a subtractive mode, and a field-sequential camera. False-color enhancement and wavelength and polarization filtering are also employed. The first of a series of flight tests indicates that an appropriately filtered conventional TV camera is a relatively inexpensive method of improving contrast between oil and water. False-color enhancement improves the contrast, but the problem caused by sun glint now limits the application to overcast days. Future effort will be aimed toward a one-camera system. Solving the sun-glint problem and developing the field-sequential camera into an operable system offers potential for color 'flagging' oil on water.

  7. Correlates of occupational, leisure and total sitting time in working adults: results from the Singapore multi-ethnic cohort.

    PubMed

    Uijtdewilligen, Léonie; Yin, Jason Dean-Chen; van der Ploeg, Hidde P; Müller-Riemenschneider, Falk

    2017-12-13

    Evidence on the health risks of sitting is accumulating. However, research identifying factors influencing sitting time in adults is limited, especially in Asian populations. This study aimed to identify socio-demographic and lifestyle correlates of occupational, leisure and total sitting time in a sample of Singapore working adults. Data were collected between 2004 and 2010 from participants of the Singapore Multi Ethnic Cohort (MEC). Medical exclusion criteria for cohort participation were cancer, heart disease, stroke, renal failure and serious mental illness. Participants who were not working over the past 12 months and without data on sitting time were excluded from the analyses. Multivariable regression analyses were used to examine cross-sectional associations of self-reported age, gender, ethnicity, marital status, education, smoking, caloric intake and moderate-to-vigorous leisure time physical activity (LTPA) with self-reported occupational, leisure and total sitting time. Correlates were also studied separately for Chinese, Malays and Indians. The final sample comprised 9384 participants (54.8% male): 50.5% were Chinese, 24.0% Malay, and 25.5% Indian. For the total sample, mean occupational sitting time was 2.71 h/day, mean leisure sitting time was 2.77 h/day and mean total sitting time was 5.48 h/day. Sitting time in all domains was highest among Chinese. Age, gender, education, and caloric intake were associated with higher occupational sitting time, while ethnicity, marital status and smoking were associated with lower occupational sitting time. Marital status, smoking, caloric intake and LTPA were associated with higher leisure sitting time, while age, gender and ethnicity were associated with lower leisure sitting time. Gender, marital status, education, caloric intake and LTPA were associated with higher total sitting time, while ethnicity was associated with lower total sitting time. Stratified analyses revealed different associations within sitting domains for Indians compared to Chinese and Malays. Our findings highlight the need to focus on separate domains of sitting (occupational, leisure or total) when identifying which factors determine this behavior, and that the content of intervention programs should be tailored to domain-specific sitting rather than to sitting in general. Finally, our study showed ethnic differences and therefore we recommend to culturally target interventions.

  8. Localization and Mapping Using a Non-Central Catadioptric Camera System

    NASA Astrophysics Data System (ADS)

    Khurana, M.; Armenakis, C.

    2018-05-01

    This work details the development of an indoor navigation and mapping system using a non-central catadioptric omnidirectional camera and its implementation for mobile applications. Omnidirectional catadioptric cameras find their use in navigation and mapping of robotic platforms, owing to their wide field of view. Having a wider field of view, or rather a potential 360° field of view, allows the system to "see and move" more freely in the navigation space. A catadioptric camera system is a low cost system which consists of a mirror and a camera. Any perspective camera can be used. A platform was constructed in order to combine the mirror and a camera to build a catadioptric system. A calibration method was developed in order to obtain the relative position and orientation between the two components so that they can be considered as one monolithic system. The mathematical model for localizing the system was determined using conditions based on the reflective properties of the mirror. The obtained platform positions were then used to map the environment using epipolar geometry. Experiments were performed to test the mathematical models and the achieved location and mapping accuracies of the system. An iterative process of positioning and mapping was applied to determine object coordinates of an indoor environment while navigating the mobile platform. Camera localization and 3D coordinates of object points obtained decimetre level accuracies.

  9. Design and realization of an AEC&AGC system for the CCD aerial camera

    NASA Astrophysics Data System (ADS)

    Liu, Hai ying; Feng, Bing; Wang, Peng; Li, Yan; Wei, Hao yun

    2015-08-01

    An AEC and AGC(Automatic Exposure Control and Automatic Gain Control) system was designed for a CCD aerial camera with fixed aperture and electronic shutter. The normal AEC and AGE algorithm is not suitable to the aerial camera since the camera always takes high-resolution photographs in high-speed moving. The AEC and AGE system adjusts electronic shutter and camera gain automatically according to the target brightness and the moving speed of the aircraft. An automatic Gamma correction is used before the image is output so that the image is better for watching and analyzing by human eyes. The AEC and AGC system could avoid underexposure, overexposure, or image blurring caused by fast moving or environment vibration. A series of tests proved that the system meet the requirements of the camera system with its fast adjusting speed, high adaptability, high reliability in severe complex environment.

  10. 'Endurance' Untouched (3-D)

    NASA Technical Reports Server (NTRS)

    2004-01-01

    [figure removed for brevity, see original site] Figure 1 [figure removed for brevity, see original site] Figure 2

    This navigation camera mosaic, created from images taken by NASA's Mars Exploration Rover Opportunity on sols 115 and 116 (May 21 and 22, 2004) provides a dramatic view of 'Endurance Crater.' The rover engineering team carefully plotted the safest path into the football field-sized crater, eventually easing the rover down the slopes around sol 130 (June 12, 2004). To the upper left of the crater sits the rover's protective heatshield, which sheltered Opportunity as it passed through the martian atmosphere. The 360-degree, stereo view is presented in a cylindrical-perspective projection, with geometric and radiometric seam correction.

    Figure 1 is the left-eye view of a stereo pair and Figure 2 is the right-eye view of a stereo pair.

  11. Overview of a Hybrid Underwater Camera System

    DTIC Science & Technology

    2014-07-01

    meters), in increments of 200ps. The camera is also equipped with 6:1 motorized zoom lens. A precision miniature attitude, heading reference system ( AHRS ...LUCIE Control & Power Distribution System AHRS Pulsed LASER Gated Camera -^ Sonar Transducer (b) LUCIE sub-systems Proc. ofSPIEVol. 9111

  12. [Microeconomics of introduction of a PET system based on the revised Japanese National Insurance reimbursement system].

    PubMed

    Abe, Katsumi; Kosuda, Shigeru; Kusano, Shoichi; Nagata, Masayoshi

    2003-11-01

    It is crucial to evaluate an annual balance before-hand when an institution installs a PET system because the revised Japanese national insurance reimbursement system set the cost of a FDG PET study as 75,000 yen. A break-even point was calculated in an 8-hour or a 24-hour operation of a PET system, based on the total costs reported. The break-even points were as follows: 13.4, 17.7, 22.1 studies per day for the 1 cyclotron-1 PET camera, 1 cyclotron-2 PET cameras, 1 cyclotron-3 PET cameras system, respectively, in an ordinary PET system operation of 8 hours. The break-even points were 19.9, 25.5, 31.2 studies per day for the 1 cyclotron-1 PET camera, 1 cyclotron-2 PET cameras, 1 cyclotron-3 PET cameras system, respectively, in a full PET system operation of 24 hours. The results indicate no profit would accrue in an ordinary PET system operation of 8 hours. The annual profit and break-even point for the total cost including the initial investment would be respectively 530 million yen and 2.8 years in a 24-hour operation with 1 cyclotron-3 PET cameras system.

  13. Effects of different seating equipment on postural control and upper extremity function in children with cerebral palsy.

    PubMed

    Sahinoğlu, Dilek; Coskun, Gürsoy; Bek, Nilgün

    2017-02-01

    Adaptive seating supports for cerebral palsy are recommended to develop and maintain optimum posture, and functional use of upper extremities. To compare the effectiveness of different seating adaptations regarding postural alignment and related functions and to investigate the effects of these seating adaptations on different motor levels. Prospective study. A total of 20 children with spastic cerebral palsy (Gross Motor Function Classification System 3-5) were included. Postural control and function (Seated Postural Control Measure, Sitting Assessment Scale) were measured in three different systems: standard chair, adjustable seating system and custom-made orthosis. In results of all participants ungrouped, there was a significant difference in most parameters of both measurement tools in favor of custom-made orthosis and adjustable seating system when compared to standard chair ( p < 0.0017). There was a difference among interventions in most of the Seated Postural Control Measure results in Level 4 when subjects were grouped according to Gross Motor Function Classification System levels. A difference was observed between standard chair and adjustable seating system in foot control, arm control, and total Sitting Assessment Scale scores; and between standard chair and custom-made orthosis in trunk control, arm control, and total Sitting Assessment Scale score in Level 4. There was no difference in adjustable seating system and custom-made orthosis in Sitting Assessment Scale in this group of children ( p < 0.017). Although custom-made orthosis fabrication is time consuming, it is still recommended since it is custom made, easy to use, and low-cost. On the other hand, the adjustable seating system can be modified according to a patient's height and weight. Clinical relevance It was found that Gross Motor Function Classification System Level 4 children benefitted most from the seating support systems. It was presented that standard chair is sufficient in providing postural alignment. Both custom-made orthosis and adjustable seating system have pros and cons and the best solution for each will be dependent on a number of factors.

  14. The development of large-aperture test system of infrared camera and visible CCD camera

    NASA Astrophysics Data System (ADS)

    Li, Yingwen; Geng, Anbing; Wang, Bo; Wang, Haitao; Wu, Yanying

    2015-10-01

    Infrared camera and CCD camera dual-band imaging system is used in many equipment and application widely. If it is tested using the traditional infrared camera test system and visible CCD test system, 2 times of installation and alignment are needed in the test procedure. The large-aperture test system of infrared camera and visible CCD camera uses the common large-aperture reflection collimator, target wheel, frame-grabber, computer which reduces the cost and the time of installation and alignment. Multiple-frame averaging algorithm is used to reduce the influence of random noise. Athermal optical design is adopted to reduce the change of focal length location change of collimator when the environmental temperature is changing, and the image quality of the collimator of large field of view and test accuracy are also improved. Its performance is the same as that of the exotic congener and is much cheaper. It will have a good market.

  15. Assessment of the DoD Embedded Media Program

    DTIC Science & Technology

    2004-09-01

    Classified and Sensitive Information ................... VII-22 3. Weapons Systems Video, Gun Camera Video, and Lipstick Cameras...Weapons Systems Video, Gun Camera Video, and Lipstick Cameras A SECDEF and CJCS message to commanders stated, “Put in place mechanisms and processes...of public communication activities.”126 The 10 February 2003 PAG stated, “Use of lipstick and helmet-mounted cameras on combat sorties is approved

  16. Mobile Phone Use Behaviors and Postures on Public Transportation Systems

    PubMed Central

    Liang, Huey-Wen; Hwang, Yaw-Huei

    2016-01-01

    Mobile phones are common in our daily life, but the users’ preferences for postures or screen operating styles have not been studied. This was a cross-sectional and observational study. We randomly sampled passengers who used mobile phones on the Mass Rapid Transit (MRT) system in metropolitan Taipei. A checklist was used to observe their body postures and screen operating styles while sitting or standing. As a result, 1,230 subjects from 400 trips were observed. Overall, of all the passengers who were sitting, 41% of them were using mobile phones. The majority of the tasks involved browsing (84%) with their phones in a portrait orientation (93%). Different-hand holding/operating was the most commonly used operating style while sitting (46%) and same-hand holding/operating was the most common while standing (46%). The distribution of screen operating styles was significantly different for those sitting than for those standing and for different genders and age groups. The most frequently observed postures while sitting were having one’s trunk against a backrest, feet on the floor and with or without an arm supported (58%). As for the users who were standing, the both- and different-hands groups had a high proportion of arms unsupported, feet on the floor and either their trunk supported or not. In contrast, the same-hand group tended to have their trunk unsupported, were holding a pole or handstrap and had both feet on floor. Further studies are warranted to characterize the ergonomic exposure of these commonly used postures and operating styles, and our results will help guide the selection of experimental conditions for laboratory settings. PMID:26828797

  17. Lytro camera technology: theory, algorithms, performance analysis

    NASA Astrophysics Data System (ADS)

    Georgiev, Todor; Yu, Zhan; Lumsdaine, Andrew; Goma, Sergio

    2013-03-01

    The Lytro camera is the first implementation of a plenoptic camera for the consumer market. We consider it a successful example of the miniaturization aided by the increase in computational power characterizing mobile computational photography. The plenoptic camera approach to radiance capture uses a microlens array as an imaging system focused on the focal plane of the main camera lens. This paper analyzes the performance of Lytro camera from a system level perspective, considering the Lytro camera as a black box, and uses our interpretation of Lytro image data saved by the camera. We present our findings based on our interpretation of Lytro camera file structure, image calibration and image rendering; in this context, artifacts and final image resolution are discussed.

  18. Is questionnaire-based sitting time inaccurate and can it be improved? A cross-sectional investigation using accelerometer-based sitting time

    PubMed Central

    Gupta, Nidhi; Christiansen, Caroline Stordal; Hanisch, Christiana; Bay, Hans; Burr, Hermann; Holtermann, Andreas

    2017-01-01

    Objectives To investigate the differences between a questionnaire-based and accelerometer-based sitting time, and develop a model for improving the accuracy of questionnaire-based sitting time for predicting accelerometer-based sitting time. Methods 183 workers in a cross-sectional study reported sitting time per day using a single question during the measurement period, and wore 2 Actigraph GT3X+ accelerometers on the thigh and trunk for 1–4 working days to determine their actual sitting time per day using the validated Acti4 software. Least squares regression models were fitted with questionnaire-based siting time and other self-reported predictors to predict accelerometer-based sitting time. Results Questionnaire-based and accelerometer-based average sitting times were ≈272 and ≈476 min/day, respectively. A low Pearson correlation (r=0.32), high mean bias (204.1 min) and wide limits of agreement (549.8 to −139.7 min) between questionnaire-based and accelerometer-based sitting time were found. The prediction model based on questionnaire-based sitting explained 10% of the variance in accelerometer-based sitting time. Inclusion of 9 self-reported predictors in the model increased the explained variance to 41%, with 10% optimism using a resampling bootstrap validation. Based on a split validation analysis, the developed prediction model on ≈75% of the workers (n=132) reduced the mean and the SD of the difference between questionnaire-based and accelerometer-based sitting time by 64% and 42%, respectively, in the remaining 25% of the workers. Conclusions This study indicates that questionnaire-based sitting time has low validity and that a prediction model can be one solution to materially improve the precision of questionnaire-based sitting time. PMID:28093433

  19. Single-snapshot 2D color measurement by plenoptic imaging system

    NASA Astrophysics Data System (ADS)

    Masuda, Kensuke; Yamanaka, Yuji; Maruyama, Go; Nagai, Sho; Hirai, Hideaki; Meng, Lingfei; Tosic, Ivana

    2014-03-01

    Plenoptic cameras enable capture of directional light ray information, thus allowing applications such as digital refocusing, depth estimation, or multiband imaging. One of the most common plenoptic camera architectures contains a microlens array at the conventional image plane and a sensor at the back focal plane of the microlens array. We leverage the multiband imaging (MBI) function of this camera and develop a single-snapshot, single-sensor high color fidelity camera. Our camera is based on a plenoptic system with XYZ filters inserted in the pupil plane of the main lens. To achieve high color measurement precision of this system, we perform an end-to-end optimization of the system model that includes light source information, object information, optical system information, plenoptic image processing and color estimation processing. Optimized system characteristics are exploited to build an XYZ plenoptic colorimetric camera prototype that achieves high color measurement precision. We describe an application of our colorimetric camera to color shading evaluation of display and show that it achieves color accuracy of ΔE<0.01.

  20. Energy-efficient lighting system for television

    DOEpatents

    Cawthorne, Duane C.

    1987-07-21

    A light control system for a television camera comprises an artificial light control system which is cooperative with an iris control system. This artificial light control system adjusts the power to lamps illuminating the camera viewing area to provide only sufficient artificial illumination necessary to provide a sufficient video signal when the camera iris is substantially open.

  1. Normalized Metadata Generation for Human Retrieval Using Multiple Video Surveillance Cameras.

    PubMed

    Jung, Jaehoon; Yoon, Inhye; Lee, Seungwon; Paik, Joonki

    2016-06-24

    Since it is impossible for surveillance personnel to keep monitoring videos from a multiple camera-based surveillance system, an efficient technique is needed to help recognize important situations by retrieving the metadata of an object-of-interest. In a multiple camera-based surveillance system, an object detected in a camera has a different shape in another camera, which is a critical issue of wide-range, real-time surveillance systems. In order to address the problem, this paper presents an object retrieval method by extracting the normalized metadata of an object-of-interest from multiple, heterogeneous cameras. The proposed metadata generation algorithm consists of three steps: (i) generation of a three-dimensional (3D) human model; (ii) human object-based automatic scene calibration; and (iii) metadata generation. More specifically, an appropriately-generated 3D human model provides the foot-to-head direction information that is used as the input of the automatic calibration of each camera. The normalized object information is used to retrieve an object-of-interest in a wide-range, multiple-camera surveillance system in the form of metadata. Experimental results show that the 3D human model matches the ground truth, and automatic calibration-based normalization of metadata enables a successful retrieval and tracking of a human object in the multiple-camera video surveillance system.

  2. Normalized Metadata Generation for Human Retrieval Using Multiple Video Surveillance Cameras

    PubMed Central

    Jung, Jaehoon; Yoon, Inhye; Lee, Seungwon; Paik, Joonki

    2016-01-01

    Since it is impossible for surveillance personnel to keep monitoring videos from a multiple camera-based surveillance system, an efficient technique is needed to help recognize important situations by retrieving the metadata of an object-of-interest. In a multiple camera-based surveillance system, an object detected in a camera has a different shape in another camera, which is a critical issue of wide-range, real-time surveillance systems. In order to address the problem, this paper presents an object retrieval method by extracting the normalized metadata of an object-of-interest from multiple, heterogeneous cameras. The proposed metadata generation algorithm consists of three steps: (i) generation of a three-dimensional (3D) human model; (ii) human object-based automatic scene calibration; and (iii) metadata generation. More specifically, an appropriately-generated 3D human model provides the foot-to-head direction information that is used as the input of the automatic calibration of each camera. The normalized object information is used to retrieve an object-of-interest in a wide-range, multiple-camera surveillance system in the form of metadata. Experimental results show that the 3D human model matches the ground truth, and automatic calibration-based normalization of metadata enables a successful retrieval and tracking of a human object in the multiple-camera video surveillance system. PMID:27347961

  3. Composite video and graphics display for multiple camera viewing system in robotics and teleoperation

    NASA Technical Reports Server (NTRS)

    Diner, Daniel B. (Inventor); Venema, Steven C. (Inventor)

    1991-01-01

    A system for real-time video image display for robotics or remote-vehicle teleoperation is described that has at least one robot arm or remotely operated vehicle controlled by an operator through hand-controllers, and one or more television cameras and optional lighting element. The system has at least one television monitor for display of a television image from a selected camera and the ability to select one of the cameras for image display. Graphics are generated with icons of cameras and lighting elements for display surrounding the television image to provide the operator information on: the location and orientation of each camera and lighting element; the region of illumination of each lighting element; the viewed region and range of focus of each camera; which camera is currently selected for image display for each monitor; and when the controller coordinate for said robot arms or remotely operated vehicles have been transformed to correspond to coordinates of a selected or nonselected camera.

  4. Composite video and graphics display for camera viewing systems in robotics and teleoperation

    NASA Technical Reports Server (NTRS)

    Diner, Daniel B. (Inventor); Venema, Steven C. (Inventor)

    1993-01-01

    A system for real-time video image display for robotics or remote-vehicle teleoperation is described that has at least one robot arm or remotely operated vehicle controlled by an operator through hand-controllers, and one or more television cameras and optional lighting element. The system has at least one television monitor for display of a television image from a selected camera and the ability to select one of the cameras for image display. Graphics are generated with icons of cameras and lighting elements for display surrounding the television image to provide the operator information on: the location and orientation of each camera and lighting element; the region of illumination of each lighting element; the viewed region and range of focus of each camera; which camera is currently selected for image display for each monitor; and when the controller coordinate for said robot arms or remotely operated vehicles have been transformed to correspond to coordinates of a selected or nonselected camera.

  5. Reducing Office Workers' Sitting Time at Work Using Sit-Stand Protocols: Results From a Pilot Randomized Controlled Trial.

    PubMed

    Li, Ingrid; Mackey, Martin G; Foley, Bridget; Pappas, Evangelos; Edwards, Kate; Chau, Josephine Y; Engelen, Lina; Voukelatos, Alexander; Whelan, Anna; Bauman, Adrian; Winkler, Elisabeth; Stamatakis, Emmanuel

    2017-06-01

    To examine the effects of different sit-stand protocols on work-time sitting and physical activity (PA) of office workers. Participants (n = 26, 77% women, mean age 42) were randomly allocated to usual sitting (control) or one of three sit-stand protocols (intervention) facilitated by height-adjustable workstations for a 4-week period between June and August 2015. Sitting, standing, and stepping time were assessed by inclinometry (activPAL); leisure-time physical activity (LTPA) by self-report. One-way analysis of covariance (ANCOVA) and post-hoc (Bonferroni) tests explored between-group differences. Compared with baseline, intervention groups reduced work sitting time by 113 minutes/8-hour workday (95% confidence interval [CI] [-147,-79]) and increased work standing time by 96 minutes/8-hour workday (95% CI [67,125]) without significantly impacting LTPA/sleep time. Sit-stand protocols facilitated by height-adjustable workstations appear to reduce office workers' sitting time without significant adverse effects on LTPA.

  6. Preventing and Treating Peri-Implantitis: A Cost-Effectiveness Analysis.

    PubMed

    Schwendicke, Falk; Tu, Yu-Kang; Stolpe, Michael

    2015-09-01

    A large number of treatments for peri-implantitis are available, but their cost-effectiveness remains uncertain. This study evaluates the cost-effectiveness of preventing and treating peri-implantitis. A Markov model was constructed that followed each implant over 20 years. Supportive implant therapy (SIT) for managing peri-implant mucositis and preventing development of peri-implantitis was either provided or not. Risk of peri-implantitis was assumed to be affected by SIT and the patient's risk profile. If peri-implantitis occurred, 11 treatment strategies (non-surgical or surgical debridement alone or combined with adjunct therapies) were compared. Treatments and risk profiles determined disease progression. Modeling was performed based on systematically collected data. Primary outcomes were costs and proportion of lost implants, as assessed via Monte Carlo microsimulations. Not providing SIT and performing only non-surgical debridement was both least costly and least effective. The next best (more costly and effective) option was to provide SIT and perform surgical debridement (additional 0.89 euros per 1% fewer implants lost). The most effective option included bone grafts, membranes, and laser treatment (56 euros per 1%). For patients at high risk, the cost-effectiveness of SIT increased, whereas in low-risk groups, a cost-optimized strategy was cost-effective. Although clinical decision-making will be guided mainly by clinical condition, cost-effectiveness analyses might add another perspective. Based on these findings, an unambiguous comparative effectiveness ranking was not established. However, cost-effectiveness was predominantly determined by provision of SIT and initial treatment costs. Transferability of these findings to other healthcare systems needs further confirmation.

  7. Difference in caloric expenditure in sitting versus standing desks.

    PubMed

    Reiff, Christopher; Marlatt, Kara; Dengel, Donald R

    2012-09-01

    Traditional desks require students to sit; however, recently schools have provided students with nontraditional standing desks. The purpose of this study was to investigate differences in caloric expenditure of young adults while sitting at a standard classroom desk and standing at a nontraditional standing classroom desk. Twenty (10 male/10 female) young (22.8 ± 1.9 y), healthy participants reported to the laboratory between the hours of 7:00 AM and 2:00 PM following a 12-h fast and 48-h break in exercise. Participants were randomly assigned to perform a series of mathematical problems either sitting at a normal classroom desk or standing at a nontraditional standing desk. Inspired and expired gases were collected for 45-min for the determination of oxygen consumption (VO2), carbon dioxide production (VCO2), and minute ventilation (VE) using a metabolic gas system. There were significant increases from sitting to standing in VO2 (0.22 ± 0.05 vs. 0.28 ± 0.05 L·min-1, P ≤ .0001), VCO2 (0.18 ± 0.05 vs. 0.24 ± 0.050 L·min-1, P ≤ .0001), VE (7.72 ± 0.67 vs. 9.41 ± 1.20 L·min-1, P ≤ .0001), and kilocalories expended per minute (1.36 ± 0.20 kcal/min, P ≤ .0001 vs. 1.02 ± 0.22 kcal/min, P ≤ .0001). Results indicate a significant increase in caloric expenditure in subjects that were standing at a standing classroom desk compared with sitting at a standard classroom desk.

  8. Tests of commercial colour CMOS cameras for astronomical applications

    NASA Astrophysics Data System (ADS)

    Pokhvala, S. M.; Reshetnyk, V. M.; Zhilyaev, B. E.

    2013-12-01

    We present some results of testing commercial colour CMOS cameras for astronomical applications. Colour CMOS sensors allow to perform photometry in three filters simultaneously that gives a great advantage compared with monochrome CCD detectors. The Bayer BGR colour system realized in colour CMOS sensors is close to the astronomical Johnson BVR system. The basic camera characteristics: read noise (e^{-}/pix), thermal noise (e^{-}/pix/sec) and electronic gain (e^{-}/ADU) for the commercial digital camera Canon 5D MarkIII are presented. We give the same characteristics for the scientific high performance cooled CCD camera system ALTA E47. Comparing results for tests of Canon 5D MarkIII and CCD ALTA E47 show that present-day commercial colour CMOS cameras can seriously compete with the scientific CCD cameras in deep astronomical imaging.

  9. Research on the electro-optical assistant landing system based on the dual camera photogrammetry algorithm

    NASA Astrophysics Data System (ADS)

    Mi, Yuhe; Huang, Yifan; Li, Lin

    2015-08-01

    Based on the location technique of beacon photogrammetry, Dual Camera Photogrammetry (DCP) algorithm was used to assist helicopters landing on the ship. In this paper, ZEMAX was used to simulate the two Charge Coupled Device (CCD) cameras imaging four beacons on both sides of the helicopter and output the image to MATLAB. Target coordinate systems, image pixel coordinate systems, world coordinate systems and camera coordinate systems were established respectively. According to the ideal pin-hole imaging model, the rotation matrix and translation vector of the target coordinate systems and the camera coordinate systems could be obtained by using MATLAB to process the image information and calculate the linear equations. On the basis mentioned above, ambient temperature and the positions of the beacons and cameras were changed in ZEMAX to test the accuracy of the DCP algorithm in complex sea status. The numerical simulation shows that in complex sea status, the position measurement accuracy can meet the requirements of the project.

  10. Immediate effects of dynamic sitting exercise on the lower back mobility of sedentary young adults

    PubMed Central

    Chatchawan, Uraiwan; Jupamatangb, Unthika; Chanchitc, Sunisa; Puntumetakul, Rungthip; Donpunha, Wanida; Yamauchi, Junichiro

    2015-01-01

    [Purpose] The aim of this study was to investigate the effects of dynamic sitting exercises during prolonged sitting on the lower back mobility of sedentary young adults. [Subjects and Methods] Seventy-one subjects aged between 18–25 years participated in this study. Following a randomized crossover study design, subjects were randomly assigned to two groups: sitting only and dynamic sitting exercise. The dynamic sitting exercise was a combination of lower back hyperextension and abdominal drawing-in movements which were repeated 6 times in a 1-minute period and performed every 20 minutes during a 2-hour sitting session. Lumbar range of movement was measured with the modified-modified Schober test, and the pain intensity was evaluated using the visual analog scale. [Results] After the experiment, the lumbar range of movement was significantly impaired in the sitting only group; however, it was significantly improved in the dynamic sitting exercise group. There were significant differences in lumbar range of movement of both flexion and extension between the groups. No significant difference in pain intensity between the groups was found. [Conclusion] These results suggest that dynamic sitting exercises during prolonged sitting can prevent decreases in lumbar range of movement in both back flexion and extension following a 2-hour sitting period. PMID:26696698

  11. Low-cost digital dynamic visualization system

    NASA Astrophysics Data System (ADS)

    Asundi, Anand K.; Sajan, M. R.

    1995-05-01

    High speed photographic systems like the image rotation camera, the Cranz Schardin camera and the drum camera are typically used for recording and visualization of dynamic events in stress analysis, fluid mechanics, etc. All these systems are fairly expensive and generally not simple to use. Furthermore they are all based on photographic film recording systems requiring time consuming and tedious wet processing of the films. Currently digital cameras are replacing to certain extent the conventional cameras for static experiments. Recently, there is lot of interest in developing and modifying CCD architectures and recording arrangements for dynamic scene analysis. Herein we report the use of a CCD camera operating in the Time Delay and Integration (TDI) mode for digitally recording dynamic scenes. Applications in solid as well as fluid impact problems are presented.

  12. Stand Out in Class: restructuring the classroom environment to reduce sedentary behaviour in 9-10-year-olds - study protocol for a pilot cluster randomised controlled trial.

    PubMed

    Clemes, Stacy A; Bingham, Daniel D; Pearson, Natalie; Chen, Yu-Ling; Edwardson, Charlotte; McEachan, Rosemary; Tolfrey, Keith; Cale, Lorraine; Richardson, Gerry; Fray, Mike; Bandelow, Stephan; Jaicim, Nishal Bhupendra; Salmon, Jo; Dunstan, David; Barber, Sally E

    2018-01-01

    Sedentary behaviour (sitting) is a highly prevalent negative health behaviour, with individuals of all ages exposed to environments that promote prolonged sitting. Excessive sedentary behaviour adversely affects health in children and adults. As sedentary behaviour tracks from childhood into adulthood, the reduction of sedentary time in young people is key for the prevention of chronic diseases that result from excessive sitting in later life. The sedentary school classroom represents an ideal setting for environmental change, through the provision of sit-stand desks. Whilst the use of sit-stand desks in classrooms demonstrates positive effects in some key outcomes, evidence is currently limited by small samples and/or short intervention durations, with few studies adopting randomised controlled trial (RCT) designs. This paper describes the protocol of a pilot cluster RCT of a sit-stand desk intervention in primary school classrooms. A two-arm pilot cluster RCT will be conducted in eight primary schools (four intervention, four control) with at least 120 year 5 children (aged 9-10 years). Sit-stand desks will replace six standard desks in the intervention classrooms. Teachers will be encouraged to ensure all pupils are exposed to the sit-stand desks for at least 1 h/day on average using a rotation system. Schools assigned to the control arm will continue with their usual practice, no environmental changes will be made to their classrooms. Measurements will be taken at baseline, before randomisation, and at the end of the schools' academic year. In this study, the primary outcomes of interest will be school and participant recruitment and attrition, acceptability of the intervention, and acceptability and compliance to the proposed outcome measures (including activPAL-measured school-time and school-day sitting, accelerometer-measured physical activity, adiposity, blood pressure, cognitive function, academic progress, engagement, and behaviour) for inclusion in a definitive trial. A full process evaluation and an exploratory economic evaluation will also be conducted to further inform a definitive trial. The primary output of this study will be acceptability data to inform the development of a definitive cluster RCT designed to examine the efficacy of this intervention on health- and education-related outcomes in UK primary school children. ISRCTN12915848 (retrospectively registered, date registered 9 November 2016).

  13. Phase III Simplified Integrated Test (SIT) results - Space Station ECLSS testing

    NASA Technical Reports Server (NTRS)

    Roberts, Barry C.; Carrasquillo, Robyn L.; Dubiel, Melissa Y.; Ogle, Kathryn Y.; Perry, Jay L.; Whitley, Ken M.

    1990-01-01

    During 1989, phase III testing of Space Station Freedom Environmental Control and Life Support Systems (ECLSS) began at Marshall Space Flight Center (MSFC) with the Simplified Integrated Test. This test, conducted at the MSFC Core Module Integration Facility (CMIF), was the first time the four baseline air revitalization subsystems were integrated together. This paper details the results and lessons learned from the phase III SIT. Future plans for testing at the MSFC CMIF are also discussed.

  14. Repetitive sit-to-stand training with the step-foot position on the non-paretic side, and its effects on the balance and foot pressure of chronic stroke subjects

    PubMed Central

    Kim, Kyung; Kim, Young Mi; Kang, Dong Yeon

    2015-01-01

    [Purpose] This study aimed to improve the asymmetrical weight-bearing ratio by applying repetitive sit-to-stand training methods that feature a step-foot position to the paretic-side foot of hemiplegic patients; it sought also to provide the information needed to apply weight-bearing and balance training to hemiplegic patients. [Subjects and Methods] The subjects were divided into two groups: a spontaneous group and a step group. They all performed repetitive sit-to-stand training five times per week for a total of six weeks. The Biodex Balance System, TUG, and 5XSST were used to measure the static and dynamic standing balance of each patient. A foot mat system was used to measure foot pressure. [Results] In the balance measurements, differences in the Overall index, Ant-post index, Med-lat index, Fall risk index, TUG, and 5XSST after training was significantly different between the two study groups. In evaluating foot pressure measurements, we found that the COP (Ant-post), Peak pressure: hind foot, and Contact area: hind foot measurements significantly differed between the groups after the training. [Conclusion] Repetitive sit-to-stand training that involves positioning the non-paretic leg upward can be considered a significant form of training that improves the symmetric posture adjustment and balance of hemiplegic patients following a stroke. PMID:26357448

  15. Separate and joint associations of occupational and leisure-time sitting with cardio-metabolic risk factors in working adults: a cross-sectional study.

    PubMed

    Saidj, Madina; Jørgensen, Torben; Jacobsen, Rikke K; Linneberg, Allan; Aadahl, Mette

    2013-01-01

    The workplace is a main setting for prolonged sitting for some occupational groups. Convincing evidence has recently accumulated on the detrimental cardio-metabolic health effects of leisure-time sitting. Yet, much less is known about occupational sitting, and the potential health risk attached compared to leisure-time sitting. To explore the separate and joint associations of occupational and leisure-time sitting with cardio-metabolic risk factors in working adults. All working adults (N = 2544) from the Health2006, a Danish population-based study, were included in this cross-sectional study. Participants reported hours of sitting during work, during leisure-time along with socio-demographic and behavioral characteristics, including physical activity. Cardio-metabolic risk factors (waist circumference, body mass index, body fat percentage, total cholesterol, HDL cholesterol, LDL cholesterol, triglycerides, insulin, hemoglobin A1c and plasma glucose) were measured. Associations were explored by linear regression for leisure-time, occupational, and overall sitting time. Statistically significant (p<.05) detrimental associations of leisure-time sitting were observed with all cardio-metabolic risk factors, except hemoglobin A1c and plasma glucose. Similarly, occupational sitting time was significantly detrimentally associated with HDL cholesterol, triglycerides, and insulin. For categories of sitting time, a joint adverse association of sitting much during both work-time and leisure-time was observed. The associations of occupational sitting time with cardio-metabolic risk factors were fewer and weaker compared to leisure-time sitting. Yet, the joint associations of occupational and leisure-time sitting with cardio-metabolic risk factors were higher than the separate. Our findings amplify the need for further focus in this area prior to making assumptions about equivalent health risks across sedentary behaviors. To our knowledge, this is the first study to contrast the deleterious associations of prolonged occupational and leisure-time sitting, both separately and jointly.

  16. Prior exercise and standing as strategies to circumvent sitting-induced leg endothelial dysfunction.

    PubMed

    Morishima, Takuma; Restaino, Robert M; Walsh, Lauren K; Kanaley, Jill A; Padilla, Jaume

    2017-06-01

    We have previously shown that local heating or leg fidgeting can prevent prolonged sitting-induced leg endothelial dysfunction. However, whether physical activity prevents subsequent sitting-induced leg endothelial dysfunction remains unknown. Herein, we tested the hypothesis that sitting-induced leg endothelial dysfunction would be prevented by prior exercise. We also examined if, in the absence of exercise, standing is an effective alternative strategy to sitting for conserving leg endothelial function. Fifteen young healthy subjects completed three randomized experimental trials: (1) sitting without prior exercise; (2) sitting with prior exercise; and (3) standing without prior exercise. Following baseline popliteal artery flow-mediated dilation (FMD) measurements, subjects maintained a supine position for 45 min in the sitting and standing trials, without prior exercise, or performed 45 min of leg cycling before sitting (i.e. sitting with prior exercise trial). Thereafter, subjects were positioned into a seated or standing position, according to the trial, for 3 h. Popliteal artery FMD measures were then repeated. Three hours of sitting without prior exercise caused a significant impairment in popliteal artery FMD (baseline: 3.8±0.5%, post-sitting: 1.5±0.5%, P <0.05), which was prevented when sitting was preceded by a bout of cycling exercise (baseline: 3.8±0.5%, post-sitting: 3.6±0.7%, P >0.05). Three hours of standing did not significantly alter popliteal artery FMD (baseline: 4.1±0.4%, post-standing: 4.3±0.4%, P >0.05). In conclusion, prolonged sitting-induced leg endothelial dysfunction can be prevented by prior aerobic exercise. In addition, in the absence of exercise, standing represents an effective substitute to sitting for preserving leg conduit artery endothelial function. © 2017 The Author(s). published by Portland Press Limited on behalf of the Biochemical Society.

  17. Association of biopsychosocial factors with degree of slump in sitting posture and self-report of back pain in adolescents: a cross-sectional study.

    PubMed

    O'Sullivan, Peter B; Smith, Anne J; Beales, Darren J; Straker, Leon M

    2011-04-01

    Conflicting evidence exists regarding relationships among sitting posture, factors that influence sitting posture, and back pain. This conflicting evidence may partially be due to the presence of multiple and overlapping factors associated with both sitting posture and back pain. The purpose of this study was to determine whether the degree of slump in sitting was associated with sex and other physical, lifestyle, or psychosocial factors. Additionally, the relationship between the report of back pain made worse by sitting and the degree of slump in sitting and other physical, lifestyle, or psychosocial factors was investigated. This was a cross-sectional study. Adolescents (n=1,596) completed questionnaires to determine lifestyle and psychosocial profiles and the experience of back pain. Sagittal sitting posture, body mass index (BMI), and back muscle endurance (BME) were recorded. Standing posture subgroup categorization was determined. Multivariate analysis revealed that the most significant factor associated with the degree of slump in sitting was male sex, followed by non-neutral standing postures, lower perceived self-efficacy, lower BME, greater television use, and higher BMI. Multivariable analysis indicated poorer Child Behaviour Checklist scores were the strongest correlate of report of back pain made worse by sitting, whereas degree of slump in sitting, female sex, and BME were more weakly related. Causality cannot be determined from this cross-sectional study, and 60% of sitting posture variation was not explained by the measured variables. Slump in sitting was associated with physical correlates, as well as sex, lifestyle, and psychosocial factors, highlighting the complex, multidimensional nature of usual sitting posture in adolescents. Additionally, this study demonstrated that a greater degree of slump in sitting was only weakly associated with adolescent back pain made worse by sitting after adjustment for other physical and psychosocial factors.

  18. Investigation of Behaviorally Modified Rats for Use in Explosives Detection Systems

    DTIC Science & Technology

    1981-12-01

    c. 4o t W iet s mi4w dltr’elm-jueiealolf- ltii*liti . .t.wnu sit - ass e-nz Iati ifovit l iutr in jIrrf-rt-F1wr to. thr lkillin aitinal. il if" O.W.tf...8217joizzle iwo%𔃾 ill .,rdtr . d1a44, tit" alsa Ilsr"’I (olf..~ .4144 if i Ow .1fi4j4.Iiumi.4-l4p sit Iii- t.’ l m~I14r.414r1 d4 atiim l-. leo *.rt1.-r is...urvisisi-. I Ifi- -1its 1%a- 1.11, -esi f, rf a 1 -Illijvvt. li-es ill [ies 1 irtlit- wyit eirmr ilist-- sit . ii- IsrpIllssLitinitijl 1Imi-iid

  19. IMAX camera (12-IML-1)

    NASA Technical Reports Server (NTRS)

    1992-01-01

    The IMAX camera system is used to record on-orbit activities of interest to the public. Because of the extremely high resolution of the IMAX camera, projector, and audio systems, the audience is afforded a motion picture experience unlike any other. IMAX and OMNIMAX motion picture systems were designed to create motion picture images of superior quality and audience impact. The IMAX camera is a 65 mm, single lens, reflex viewing design with a 15 perforation per frame horizontal pull across. The frame size is 2.06 x 2.77 inches. Film travels through the camera at a rate of 336 feet per minute when the camera is running at the standard 24 frames/sec.

  20. Development of biostereometric experiments. [stereometric camera system

    NASA Technical Reports Server (NTRS)

    Herron, R. E.

    1978-01-01

    The stereometric camera was designed for close-range techniques in biostereometrics. The camera focusing distance of 360 mm to infinity covers a broad field of close-range photogrammetry. The design provides for a separate unit for the lens system and interchangeable backs on the camera for the use of single frame film exposure, roll-type film cassettes, or glass plates. The system incorporates the use of a surface contrast optical projector.

  1. A direct-view customer-oriented digital holographic camera

    NASA Astrophysics Data System (ADS)

    Besaga, Vira R.; Gerhardt, Nils C.; Maksimyak, Peter P.; Hofmann, Martin R.

    2018-01-01

    In this paper, we propose a direct-view digital holographic camera system consisting mostly of customer-oriented components. The camera system is based on standard photographic units such as camera sensor and objective and is adapted to operate under off-axis external white-light illumination. The common-path geometry of the holographic module of the system ensures direct-view operation. The system can operate in both self-reference and self-interference modes. As a proof of system operability, we present reconstructed amplitude and phase information of a test sample.

  2. Association between gross motor function and postural control in sitting in children with Cerebral Palsy: a correlational study in Spain.

    PubMed

    Montero Mendoza, Sergio; Gómez-Conesa, Antonia; Hidalgo Montesinos, María Dolores

    2015-09-16

    Cerebral palsy (CP) is one of the causes of physical disability in children. Sitting abilities can be described using the Level of Sitting Scale (LSS) and the Gross Motor Function Classification System (GMFCS). There is growing interest in the sitting posture of children with CP owing to a stable sitting position allows for the development of eye-hand coordination, functions of the upper extremities and functional skills. Besides, in recent years researchers have tried to develop a new terminology to classify the CP as performed by the Surveillance of Cerebral Palsy in Europe (SCPE), in order to improve the monitoring of the frequency of the PC, providing a framework for research and service planning. The aim of this study was to analyse the relationship between GMFCS and LSS. The second purpose was to describe how the SCPE relates to sitting abilities with the GMFCS and LSS. The study involved 139 children with CP (range 3-18 years) from 24 educational centres. Age, gender, CP classification according to SCPE, GMFCS and LSS levels were recorded by an experienced physiotherapist. A significant inverse relationship between GMFCS and LSS score levels was found (rs = -0.86, p = 0.00). 45.3% of the children capable of leaning in any direction and of re-erecting the trunk (level VIII on the LSS) could walk without limitation (level I on the GMFCS). There were differences in the distribution of the GMFCS (χ(2)(4):50.78) and LSS (χ(2)(7): 37.15) levels and CP according to the distribution of the spasticity (p < 0.01). There was a negative correlation between both scales and a relation between sitting ability and the capacity to walk with or without technical devices. GMFCS and the LSS are useful tools for describing the functional abilities and limitations of children with CP, specially sitting and mobility. Classification based on the distribution of spasticity and the gross motor function provides clinical information on the prognosis and development of children with CP.

  3. Deep Space Positioning System

    NASA Technical Reports Server (NTRS)

    Vaughan, Andrew T. (Inventor); Riedel, Joseph E. (Inventor)

    2016-01-01

    A single, compact, lower power deep space positioning system (DPS) configured to determine a location of a spacecraft anywhere in the solar system, and provide state information relative to Earth, Sun, or any remote object. For example, the DPS includes a first camera and, possibly, a second camera configured to capture a plurality of navigation images to determine a state of a spacecraft in a solar system. The second camera is located behind, or adjacent to, a secondary reflector of a first camera in a body of a telescope.

  4. Assessing Sitting across Contexts: Development of the Multicontext Sitting Time Questionnaire

    ERIC Educational Resources Information Center

    Whitfield, Geoffrey P.; Pettee Gabriel, Kelley K.; Kohl, Harold W., III.

    2013-01-01

    Purpose: To describe the development and preliminary evaluation of the Multicontext Sitting Time Questionnaire (MSTQ). Method: During development of the MSTQ, contexts and domains of sitting behavior were utilized as recall cues to improve the accuracy of sitting assessment. The terms "workday" and "nonworkday" were used to…

  5. Listening to music during sprint interval exercise: The impact on exercise attitudes and intentions.

    PubMed

    Stork, Matthew J; Martin Ginis, Kathleen A

    2017-10-01

    This study investigated the impact of listening to music during exercise on perceived enjoyment, attitudes and intentions towards sprint interval training (SIT). Twenty men (24.8 ± 4.5 years) and women (20.1 ± 2.6 years) unfamiliar with SIT exercise completed two acute sessions of SIT, one with and one without music. Perceived enjoyment, attitudes and intentions towards SIT were measured post-exercise for each condition. Attitudes and intentions to engage in SIT were also measured at baseline and follow-up. Post-exercise attitudes mediated the effects of enjoyment on intentions in the music condition (95% confidence interval [CI]: [0.01, 0.07], κ 2  = 0.36) and in the no music condition (95% CI: [0.01, 0.08], κ 2  = 0.37). Attitudes towards SIT were significantly more positive following the music than no music condition (P = 0.004), while intentions towards SIT were not (P = 0.29). Further, attitudes and intentions towards SIT did not change from baseline to follow-up (Ps > 0.05). These findings revealed that participants had relatively positive attitudes and intentions towards SIT, which did not become more negative despite experiencing intense SIT protocols. This study highlights the importance of acute affective responses to SIT exercise for influencing one's attitudes and intentions towards participating in SIT exercise. Such factors could ultimately play a key role in determining whether an individual engages in SIT exercise in the long term.

  6. Control of finite critical behaviour in a small-scale social system

    NASA Astrophysics Data System (ADS)

    Daniels, Bryan C.; Krakauer, David C.; Flack, Jessica C.

    2017-02-01

    Many adaptive systems sit near a tipping or critical point. For systems near a critical point small changes to component behaviour can induce large-scale changes in aggregate structure and function. Criticality can be adaptive when the environment is changing, but entails reduced robustness through sensitivity. This tradeoff can be resolved when criticality can be tuned. We address the control of finite measures of criticality using data on fight sizes from an animal society model system (Macaca nemestrina, n=48). We find that a heterogeneous, socially organized system, like homogeneous, spatial systems (flocks and schools), sits near a critical point; the contributions individuals make to collective phenomena can be quantified; there is heterogeneity in these contributions; and distance from the critical point (DFC) can be controlled through biologically plausible mechanisms exploiting heterogeneity. We propose two alternative hypotheses for why a system decreases the distance from the critical point.

  7. The development of multi-model rehabilitation training system for lower limb sitting function

    NASA Astrophysics Data System (ADS)

    Wu, Jianfeng; Sun, Yue; Wu, Qun

    2017-04-01

    The multi-model rehabilitation training system was manufactured according to the demands of patients' practical training. Through the use of the patient's exercise physiology information, the ability of muscle force and movement efficiency of the patient were identified. Following with medical rehabilitation therapy, the training model, a combination of active and passive training, was proposed to enhance the training efficiency and rehabilitation effect. Furthermore, taking the sitting movement training as an example, the research theory was applied in knee rehabilitation training. The results of the research provid technical support and practical reference to the relevant training equipment designs and clinical applications.

  8. Clinical applications of commercially available video recording and monitoring systems: inexpensive, high-quality video recording and monitoring systems for endoscopy and microsurgery.

    PubMed

    Tsunoda, Koichi; Tsunoda, Atsunobu; Ishimoto, ShinnIchi; Kimura, Satoko

    2006-01-01

    The exclusive charge-coupled device (CCD) camera system for the endoscope and electronic fiberscopes are in widespread use. However, both are usually stationary in an office or examination room, and a wheeled cart is needed for mobility. The total costs of the CCD camera system and electronic fiberscopy system are at least US Dollars 10,000 and US Dollars 30,000, respectively. Recently, the performance of audio and visual instruments has improved dramatically, with a concomitant reduction in their cost. Commercially available CCD video cameras with small monitors have become common. They provide excellent image quality and are much smaller and less expensive than previous models. The authors have developed adaptors for the popular mini-digital video (mini-DV) camera. The camera also provides video and acoustic output signals; therefore, the endoscopic images can be viewed on a large monitor simultaneously. The new system (a mini-DV video camera and an adaptor) costs only US Dollars 1,000. Therefore, the system is both cost-effective and useful for the outpatient clinic or casualty setting, or on house calls for the purpose of patient education. In the future, the authors plan to introduce the clinical application of a high-vision camera and an infrared camera as medical instruments for clinical and research situations.

  9. A Quasi-Static Method for Determining the Characteristics of a Motion Capture Camera System in a "Split-Volume" Configuration

    NASA Technical Reports Server (NTRS)

    Miller, Chris; Mulavara, Ajitkumar; Bloomberg, Jacob

    2001-01-01

    To confidently report any data collected from a video-based motion capture system, its functional characteristics must be determined, namely accuracy, repeatability and resolution. Many researchers have examined these characteristics with motion capture systems, but they used only two cameras, positioned 90 degrees to each other. Everaert used 4 cameras, but all were aligned along major axes (two in x, one in y and z). Richards compared the characteristics of different commercially available systems set-up in practical configurations, but all cameras viewed a single calibration volume. The purpose of this study was to determine the accuracy, repeatability and resolution of a 6-camera Motion Analysis system in a split-volume configuration using a quasistatic methodology.

  10. Streak camera receiver definition study

    NASA Technical Reports Server (NTRS)

    Johnson, C. B.; Hunkler, L. T., Sr.; Letzring, S. A.; Jaanimagi, P.

    1990-01-01

    Detailed streak camera definition studies were made as a first step toward full flight qualification of a dual channel picosecond resolution streak camera receiver for the Geoscience Laser Altimeter and Ranging System (GLRS). The streak camera receiver requirements are discussed as they pertain specifically to the GLRS system, and estimates of the characteristics of the streak camera are given, based upon existing and near-term technological capabilities. Important problem areas are highlighted, and possible corresponding solutions are discussed.

  11. Influence of sex on microvascular and macrovascular responses to prolonged sitting.

    PubMed

    Vranish, Jennifer R; Young, Benjamin E; Kaur, Jasdeep; Patik, Jordan C; Padilla, Jaume; Fadel, Paul J

    2017-04-01

    Increased daily sitting time is associated with greater cardiovascular risk, and, on average, women are more sedentary than men. Recent reports have demonstrated that prolonged sitting reduces lower leg microvascular (reactive hyperemia) and macrovascular [flow-mediated dilation (FMD)] vasodilator function. However, these studies have predominately included men, and the effects of sitting in young women are largely unexplored. This becomes important given known sex differences in vascular function. Thus, herein, we assessed popliteal artery reactive hyperemia and FMD before and after a 3-h sitting period in healthy young women ( n = 12) and men ( n = 8). In addition, resting popliteal artery hemodynamics (duplex Doppler ultrasound) and calf circumference were measured before, during, and after sitting. Resting popliteal artery shear rate was reduced to a similar extent in both groups during the sitting period (women: -48.5 ± 8.4 s -1 and men: -52.9 ± 12.3 s -1 , P = 0.45). This was accompanied by comparable increases in calf circumference in men and women ( P = 0.37). After the sitting period, popliteal artery FMD was significantly reduced in men (PreSit: 5.5 ± 0.9% and PostSit: 1.6 ± 0.4%, P < 0.001) but not women (PreSit: 4.4 ± 0.6% and PostSit: 3.6 ± 0.6%, P = 0.29). In contrast, both groups demonstrated similar reductions in hyperemic blood flow area under the curve (women: -28,860 ± 5,742 arbitrary units and men: -28,691 ± 9,685 arbitrary units, P = 0.99), indicating impaired microvascular reactivity after sitting. These findings indicate that despite comparable reductions in shear rate during 3 h of uninterrupted sitting, macrovascular function appears protected in some young women but the response was variable, whereas men exhibited more consistent reductions in FMD. In contrast, the leg microvasculature is susceptible to similar sitting-induced impairments in men and women. NEW & NOTEWORTHY We demonstrate that leg macrovascular function was consistently reduced in young men but not young women after prolonged sitting. In contrast, both men and women exhibited similar reductions in leg microvascular reactivity after sitting. These data demonstrate, for the first time, sex differences in vascular responses to prolonged sitting. Copyright © 2017 the American Physiological Society.

  12. Muscle activity patterns and spinal shrinkage in office workers using a sit-stand workstation versus a sit workstation.

    PubMed

    Gao, Ying; Cronin, Neil J; Pesola, Arto J; Finni, Taija

    2016-10-01

    Reducing sitting time by means of sit-stand workstations is an emerging trend, but further evidence is needed regarding their health benefits. This cross-sectional study compared work time muscle activity patterns and spinal shrinkage between office workers (aged 24-62, 58.3% female) who used either a sit-stand workstation (Sit-Stand group, n = 10) or a traditional sit workstation (Sit group, n = 14) for at least the past three months. During one typical workday, muscle inactivity and activity from quadriceps and hamstrings were monitored using electromyography shorts, and spinal shrinkage was measured using stadiometry before and after the workday. Compared with the Sit group, the Sit-Stand group had less muscle inactivity time (66.2 ± 17.1% vs. 80.9 ± 6.4%, p = 0.014) and more light muscle activity time (26.1 ± 12.3% vs. 14.9 ± 6.3%, p = 0.019) with no significant difference in spinal shrinkage (5.62 ± 2.75 mm vs. 6.11 ± 2.44 mm). This study provides evidence that working with sit-stand workstations can promote more light muscle activity time and less inactivity without negative effects on spinal shrinkage. Practitioner Summary: This cross-sectional study compared the effects of using a sit-stand workstation to a sit workstation on muscle activity patterns and spinal shrinkage in office workers. It provides evidence that working with a sit-stand workstation can promote more light muscle activity time and less inactivity without negative effects on spinal shrinkage.

  13. Internal Oblique and Transversus Abdominis Muscle Fatigue Induced by Slumped Sitting Posture after 1 Hour of Sitting in Office Workers

    PubMed Central

    Waongenngarm, Pooriput; Rajaratnam, Bala S.; Janwantanakul, Prawit

    2015-01-01

    Background Prolonged sitting leads to low back discomfort and lumbopelvic muscle fatigue. This study examined the characteristics of body perceived discomfort and trunk muscle fatigue during 1 hour of sitting in three postures in office workers. Methods Thirty workers sat for 1 hour in one of three sitting postures (i.e., upright, slumped, and forward leaning postures). Body discomfort was assessed using the Body Perceived Discomfort scale at the beginning and after 1 hour of sitting. Electromyographic (EMG) signals were recorded from superficial lumbar multifidus, iliocostalis lumborum pars thoracis, internal oblique (IO)/transversus abdominis (TrA), and rectus abdominis muscles during 1 hour of sitting. The median frequency (MDF) of the EMG power spectrum was calculated. Results Regardless of the sitting posture, the Body Perceived Discomfort scores in the neck, shoulder, upper back, low back, and buttock significantly increased after 1 hour of sitting compared with baseline values (t(9) = −11.97 to −2.69, p < 0.05). The MDF value of the EMG signal of rectus abdominis, iliocostalis lumborum pars thoracis, and multifidus muscles was unchanged over time in all three sitting postures. Only the right and left IO/TrA in the slumped sitting posture was significantly associated with decreased MDF over time (p = 0.019 to 0.041). Conclusion Prolonged sitting led to increased body discomfort in the neck, shoulder, upper back, low back, and buttock. No sign of trunk muscle fatigue was detected over 1 hour of sitting in the upright and forward leaning postures. Prolonged slumped sitting may relate to IO/TrA muscle fatigue, which may compromise the stability of the spine, making it susceptible to injury. PMID:27014491

  14. Test-to-test variability in motor activity during the suggested immobilization test in restless legs patients.

    PubMed

    Haba-Rubio, José; Sforza, Emilia

    2006-10-01

    To evaluate the test-to-test variability of the suggested immobilization test (SIT) in patients with restless legs syndrome (RLS). Twenty patients with primary RLS (12 men and eight women; age: 53.3+/-11.3 years) were selected for the study. We compared the results of two SITs performed on two consecutive evenings prior to polysomnographic recordings. Overall, the periodic leg movement index during the SIT (SIT PLM) and the SIT PLM index associated with sensory manifestations (SIT PLM+) were not significantly different between tests. The number of PLM sequences per SIT, the mean PLM duration and the PLM interval did not significantly change between the two consecutive tests. The pattern of temporal evolution of motor activity across the SIT was very reproducible, SIT PLM showing a clear tendency to a progressive increase across the test, with the SIT PLM+ index decreasing in the second half of the test. Despite good reproducibility, there were marked intra-individual differences. Considering the proposed cut-off value of 12 for the SIT PLM index to confirm RLS, 11 patients were positive at the first test and four additional patients became positive at the second test. SIT PLM index changes did not correlate with age, severity of disease and polysomnographic measures. Quantitative analysis of motor activity during two consecutive SITs in RLS patients showed a significant inter-test intra-individual variability unrelated to demographic, clinical or polysomnographic parameters. SIT PLM index variability suggests that a single test would not be sensitive enough for diagnostic purposes in unclear cases and that new criteria need to be applied to increase its specificity and sensitivity.

  15. Wired and Wireless Camera Triggering with Arduino

    NASA Astrophysics Data System (ADS)

    Kauhanen, H.; Rönnholm, P.

    2017-10-01

    Synchronous triggering is an important task that allows simultaneous data capture from multiple cameras. Accurate synchronization enables 3D measurements of moving objects or from a moving platform. In this paper, we describe one wired and four wireless variations of Arduino-based low-cost remote trigger systems designed to provide a synchronous trigger signal for industrial cameras. Our wireless systems utilize 315 MHz or 434 MHz frequencies with noise filtering capacitors. In order to validate the synchronization accuracy, we developed a prototype of a rotating trigger detection system (named RoTriDeS). This system is suitable to detect the triggering accuracy of global shutter cameras. As a result, the wired system indicated an 8.91 μs mean triggering time difference between two cameras. Corresponding mean values for the four wireless triggering systems varied between 7.92 and 9.42 μs. Presented values include both camera-based and trigger-based desynchronization. Arduino-based triggering systems appeared to be feasible, and they have the potential to be extended to more complicated triggering systems.

  16. Patterns of sedentary behavior in overweight and moderately obese users of the Catalan primary-health care system

    PubMed Central

    Beltran, Angela-Maria; Martín-Borràs, Carme; Lasaosa-Medina, Lourdes; Real, Jordi; Trujillo, José-Manuel; Solà-Gonfaus, Mercè; Puigdomenech, Elisa; Castillo-Ramos, Eva; Puig-Ribera, Anna; Giné-Garriga, Maria; Serra-Paya, Noemi; Rodriguez-Roca, Beatriz; Gascón-Catalán, Ana; Martín-Cantera, Carlos

    2018-01-01

    Background and objectives Prolonged sitting time (ST) has negative consequences on health. Changing this behavior is paramount in overweight/obese individuals because they are more sedentary than those with normal weight. The aim of the study was to establish the pattern of sedentary behavior and its relationship to health, socio-demographics, occupation, and education level in Catalan overweight/obese individuals. Methods A descriptive study was performed at 25 healthcare centers in Catalonia (Spain) with 464 overweight/moderately obese patients, aged25 to 65 years. Exclusion criteria were chronic diseases which contraindicated physical activity and language barriers. Face-to-face interviews were conducted to collect data on age, gender, educational level, social class, and marital status. Main outcome was ‘sitting time’ (collected by the Marshall questionnaire); chronic diseases and anthropometric measurements were registered. Results 464 patients, 58.4% women, mean age 51.9 years (SD 10.1), 76.1% married, 60% manual workers, and 48.7% had finished secondary education. Daily sitting time was 6.2 hours on working days (374 minutes/day, SD: 190), and about 6 hours on non-working ones (357 minutes/day, SD: 170). 50% of participants were sedentary ≥6 hours. The most frequent sedentary activities were: working/academic activities around 2 hours (128 minutes, SD: 183), followed by watching television, computer use, and commuting. Men sat longer than women (64 minutes more on working days and 54 minutes on non-working days), and individuals with office jobs (91 minutes),those with higher levels of education (42 minutes), and younger subjects (25 to 35 years) spent more time sitting. Conclusions In our study performed in overweight/moderately obese patients the mean sitting time was around 6 hours which was mainly spent doing work/academic activities and watching television. Men, office workers, individuals with higher education, and younger subjects had longer sitting time. Our results may help design interventions targeted at these sedentary patients to decrease sitting time. PMID:29370176

  17. Dynamic photoelasticity by TDI imaging

    NASA Astrophysics Data System (ADS)

    Asundi, Anand K.; Sajan, M. R.

    2001-06-01

    High speed photographic system like the image rotation camera, the Cranz Schardin camera and the drum camera are typically used for the recording and visualization of dynamic events in stress analysis, fluid mechanics, etc. All these systems are fairly expensive and generally not simple to use. Furthermore they are all based on photographic film recording system requiring time consuming and tedious wet processing of the films. Digital cameras are replacing the conventional cameras, to certain extent in static experiments. Recently, there is lots of interest in development and modifying CCD architectures and recording arrangements for dynamic scenes analysis. Herein we report the use of a CCD camera operating in the Time Delay and Integration mode for digitally recording dynamic photoelastic stress patterns. Applications in strobe and streak photoelastic pattern recording and system limitations will be explained in the paper.

  18. Can a smart chair improve the sitting behavior of office workers?

    PubMed

    Roossien, C C; Stegenga, J; Hodselmans, A P; Spook, S M; Koolhaas, W; Brouwer, S; Verkerke, G J; Reneman, M F

    2017-11-01

    Prolonged sitting can cause health problems and musculoskeletal discomfort. There is a need for objective and non-obstructive means of measuring sitting behavior. A 'smart' office chair can monitor sitting behavior and provide tactile feedback, aiming to improve sitting behavior. This study aimed to investigate the effect of the feedback signal on sitting behavior and musculoskeletal discomfort. In a 12-week prospective cohort study (ABCB design) among office workers (n = 45) was measured sitting duration and posture, feedback signals and musculoskeletal discomfort. Between the study phases, small changes were observed in mean sitting duration, posture and discomfort. After turning off the feedback signal, a slight increase in sitting duration was observed (10 min, p = 0.04), a slight decrease in optimally supported posture (2.8%, p < 0.01), and musculoskeletal discomfort (0.8, p < 0.01) was observed. We conclude that the 'smart' chair is able to monitor the sitting behavior, the feedback signal, however, led to small or insignificant changes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Fiber optic TV direct

    NASA Technical Reports Server (NTRS)

    Kassak, John E.

    1991-01-01

    The objective of the operational television (OTV) technology was to develop a multiple camera system (up to 256 cameras) for NASA Kennedy installations where camera video, synchronization, control, and status data are transmitted bidirectionally via a single fiber cable at distances in excess of five miles. It is shown that the benefits (such as improved video performance, immunity from electromagnetic interference and radio frequency interference, elimination of repeater stations, and more system configuration flexibility) can be realized if application of the proven fiber optic transmission concept is used. The control system will marry the lens, pan and tilt, and camera control functions into a modular based Local Area Network (LAN) control network. Such a system does not exist commercially at present since the Television Broadcast Industry's current practice is to divorce the positional controls from the camera control system. The application software developed for this system will have direct applicability to similar systems in industry using LAN based control systems.

  20. Levels of Autonomy and Autonomous System Performance Assessment for Intelligent Unmanned Systems

    DTIC Science & Technology

    2014-04-01

    LIDAR and camera sensors that is driven entirely by teleoperation would be AL 0. If that same robot used its LIDAR and camera data to generate a...obstacle detection, mapping, path planning 3 CMMAD semi- autonomous counter- mine system (Few 2010) Talon UGV, camera, LIDAR , metal detector...NCAP framework are performed on individual UMS components and do not require mission level evaluations. For example, bench testing of camera, LIDAR

  1. The imaging system design of three-line LMCCD mapping camera

    NASA Astrophysics Data System (ADS)

    Zhou, Huai-de; Liu, Jin-Guo; Wu, Xing-Xing; Lv, Shi-Liang; Zhao, Ying; Yu, Da

    2011-08-01

    In this paper, the authors introduced the theory about LMCCD (line-matrix CCD) mapping camera firstly. On top of the introduction were consists of the imaging system of LMCCD mapping camera. Secondly, some pivotal designs which were Introduced about the imaging system, such as the design of focal plane module, the video signal's procession, the controller's design of the imaging system, synchronous photography about forward and nadir and backward camera and the nadir camera of line-matrix CCD. At last, the test results of LMCCD mapping camera imaging system were introduced. The results as following: the precision of synchronous photography about forward and nadir and backward camera is better than 4 ns and the nadir camera of line-matrix CCD is better than 4 ns too; the photography interval of line-matrix CCD of the nadir camera can satisfy the butter requirements of LMCCD focal plane module; the SNR tested in laboratory is better than 95 under typical working condition(the solar incidence degree is 30, the reflectivity of the earth's surface is 0.3) of each CCD image; the temperature of the focal plane module is controlled under 30° in a working period of 15 minutes. All of these results can satisfy the requirements about the synchronous photography, the temperature control of focal plane module and SNR, Which give the guarantee of precision for satellite photogrammetry.

  2. Is questionnaire-based sitting time inaccurate and can it be improved? A cross-sectional investigation using accelerometer-based sitting time.

    PubMed

    Gupta, Nidhi; Christiansen, Caroline Stordal; Hanisch, Christiana; Bay, Hans; Burr, Hermann; Holtermann, Andreas

    2017-01-16

    To investigate the differences between a questionnaire-based and accelerometer-based sitting time, and develop a model for improving the accuracy of questionnaire-based sitting time for predicting accelerometer-based sitting time. 183 workers in a cross-sectional study reported sitting time per day using a single question during the measurement period, and wore 2 Actigraph GT3X+ accelerometers on the thigh and trunk for 1-4 working days to determine their actual sitting time per day using the validated Acti4 software. Least squares regression models were fitted with questionnaire-based siting time and other self-reported predictors to predict accelerometer-based sitting time. Questionnaire-based and accelerometer-based average sitting times were ≈272 and ≈476 min/day, respectively. A low Pearson correlation (r=0.32), high mean bias (204.1 min) and wide limits of agreement (549.8 to -139.7 min) between questionnaire-based and accelerometer-based sitting time were found. The prediction model based on questionnaire-based sitting explained 10% of the variance in accelerometer-based sitting time. Inclusion of 9 self-reported predictors in the model increased the explained variance to 41%, with 10% optimism using a resampling bootstrap validation. Based on a split validation analysis, the developed prediction model on ≈75% of the workers (n=132) reduced the mean and the SD of the difference between questionnaire-based and accelerometer-based sitting time by 64% and 42%, respectively, in the remaining 25% of the workers. This study indicates that questionnaire-based sitting time has low validity and that a prediction model can be one solution to materially improve the precision of questionnaire-based sitting time. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  3. Optical Meteor Systems Used by the NASA Meteoroid Environment Office

    NASA Technical Reports Server (NTRS)

    Kingery, A. M.; Blaauw, R. C.; Cooke, W. J.; Moser, D. E.

    2015-01-01

    The NASA Meteoroid Environment Office (MEO) uses two main meteor camera networks to characterize the meteoroid environment: an all sky system and a wide field system to study cm and mm size meteors respectively. The NASA All Sky Fireball Network consists of fifteen meteor video cameras in the United States, with plans to expand to eighteen cameras by the end of 2015. The camera design and All-Sky Guided and Real-time Detection (ASGARD) meteor detection software [1, 2] were adopted from the University of Western Ontario's Southern Ontario Meteor Network (SOMN). After seven years of operation, the network has detected over 12,000 multi-station meteors, including meteors from at least 53 different meteor showers. The network is used for speed distribution determination, characterization of meteor showers and sporadic sources, and for informing the public on bright meteor events. The NASA Wide Field Meteor Network was established in December of 2012 with two cameras and expanded to eight cameras in December of 2014. The two camera configuration saw 5470 meteors over two years of operation with two cameras, and has detected 3423 meteors in the first five months of operation (Dec 12, 2014 - May 12, 2015) with eight cameras. We expect to see over 10,000 meteors per year with the expanded system. The cameras have a 20 degree field of view and an approximate limiting meteor magnitude of +5. The network's primary goal is determining the nightly shower and sporadic meteor fluxes. Both camera networks function almost fully autonomously with little human interaction required for upkeep and analysis. The cameras send their data to a central server for storage and automatic analysis. Every morning the servers automatically generates an e-mail and web page containing an analysis of the previous night's events. The current status of the networks will be described, alongside with preliminary results. In addition, future projects, CCD photometry and broadband meteor color camera system, will be discussed.

  4. 241-AZ-101 Waste Tank Color Video Camera System Shop Acceptance Test Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    WERRY, S.M.

    2000-03-23

    This report includes shop acceptance test results. The test was performed prior to installation at tank AZ-101. Both the camera system and camera purge system were originally sought and procured as a part of initial waste retrieval project W-151.

  5. Understanding occupational sitting: prevalence, correlates and moderating effects in Australian employees.

    PubMed

    De Cocker, Katrien; Duncan, Mitch J; Short, Camille; van Uffelen, Jannique G Z; Vandelanotte, Corneel

    2014-10-01

    To (1) compare occupational sitting between different socio-demographic, health-related, work-related and psychosocial categories, (2) identity socio-demographic, health-related, work-related and psychosocial correlates of occupational sitting, and (3) examine the moderating effect of work-related factors in the relation between correlates and occupational sitting. Randomly-selected Australian adults completed a web-based survey assessing socio-demographic (country of birth, gender, age, education, income), health-related (general health, weight, physical activity), work-related (employment status, occupational task, occupational classification) and sedentary-specific psychosocial (social norm, social support, self-efficacy, control, advantages, disadvantage, intention) factors, and occupational sitting-time. t-tests, ANOVAs and multiple linear regression analyses were conducted (in 2013) on a sample of employees (n=993). Respondents sat on average for 3.75 (SD=2.45) h/day during work. Investigated correlates explained 41% of the variance in occupational sitting. More occupational sitting was associated with being male, being younger, higher education and income, part-time and full-time employment, sedentary job tasks, white-collar/professional occupations, higher BMI, and perceiving more advantages of sitting less at work. Employment status and occupational classification moderated the association between control to sit less and occupational sitting. A lack of control to sit less was associated with higher occupational sitting in part-time and full-time workers, but not in casual workers; and in white-collar and professional workers, but not in blue-collar workers. Most important contributors to occupational sitting were work-related and socio-demographic correlates. More research is needed to confirm present results. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Integrated inertial stellar attitude sensor

    NASA Technical Reports Server (NTRS)

    Brady, Tye M. (Inventor); Kourepenis, Anthony S. (Inventor); Wyman, Jr., William F. (Inventor)

    2007-01-01

    An integrated inertial stellar attitude sensor for an aerospace vehicle includes a star camera system, a gyroscope system, a controller system for synchronously integrating an output of said star camera system and an output of said gyroscope system into a stream of data, and a flight computer responsive to said stream of data for determining from the star camera system output and the gyroscope system output the attitude of the aerospace vehicle.

  7. The first satellite laser echoes recorded on the streak camera

    NASA Technical Reports Server (NTRS)

    Hamal, Karel; Prochazka, Ivan; Kirchner, Georg; Koidl, F.

    1993-01-01

    The application of the streak camera with the circular sweep for the satellite laser ranging is described. The Modular Streak Camera system employing the circular sweep option was integrated into the conventional Satellite Laser System. The experimental satellite tracking and ranging has been performed. The first satellite laser echo streak camera records are presented.

  8. Electronic camera-management system for 35-mm and 70-mm film cameras

    NASA Astrophysics Data System (ADS)

    Nielsen, Allan

    1993-01-01

    Military and commercial test facilities have been tasked with the need for increasingly sophisticated data collection and data reduction. A state-of-the-art electronic control system for high speed 35 mm and 70 mm film cameras designed to meet these tasks is described. Data collection in today's test range environment is difficult at best. The need for a completely integrated image and data collection system is mandated by the increasingly complex test environment. Instrumentation film cameras have been used on test ranges to capture images for decades. Their high frame rates coupled with exceptionally high resolution make them an essential part of any test system. In addition to documenting test events, today's camera system is required to perform many additional tasks. Data reduction to establish TSPI (time- space-position information) may be performed after a mission and is subject to all of the variables present in documenting the mission. A typical scenario would consist of multiple cameras located on tracking mounts capturing the event along with azimuth and elevation position data. Corrected data can then be reduced using each camera's time and position deltas and calculating the TSPI of the object using triangulation. An electronic camera control system designed to meet these requirements has been developed by Photo-Sonics, Inc. The feedback received from test technicians at range facilities throughout the world led Photo-Sonics to design the features of this control system. These prominent new features include: a comprehensive safety management system, full local or remote operation, frame rate accuracy of less than 0.005 percent, and phase locking capability to Irig-B. In fact, Irig-B phase lock operation of multiple cameras can reduce the time-distance delta of a test object traveling at mach-1 to less than one inch during data reduction.

  9. Modulated electron-multiplied fluorescence lifetime imaging microscope: all-solid-state camera for fluorescence lifetime imaging.

    PubMed

    Zhao, Qiaole; Schelen, Ben; Schouten, Raymond; van den Oever, Rein; Leenen, René; van Kuijk, Harry; Peters, Inge; Polderdijk, Frank; Bosiers, Jan; Raspe, Marcel; Jalink, Kees; Geert Sander de Jong, Jan; van Geest, Bert; Stoop, Karel; Young, Ian Ted

    2012-12-01

    We have built an all-solid-state camera that is directly modulated at the pixel level for frequency-domain fluorescence lifetime imaging microscopy (FLIM) measurements. This novel camera eliminates the need for an image intensifier through the use of an application-specific charge coupled device design in a frequency-domain FLIM system. The first stage of evaluation for the camera has been carried out. Camera characteristics such as noise distribution, dark current influence, camera gain, sampling density, sensitivity, linearity of photometric response, and optical transfer function have been studied through experiments. We are able to do lifetime measurement using our modulated, electron-multiplied fluorescence lifetime imaging microscope (MEM-FLIM) camera for various objects, e.g., fluorescein solution, fixed green fluorescent protein (GFP) cells, and GFP-actin stained live cells. A detailed comparison of a conventional microchannel plate (MCP)-based FLIM system and the MEM-FLIM system is presented. The MEM-FLIM camera shows higher resolution and a better image quality. The MEM-FLIM camera provides a new opportunity for performing frequency-domain FLIM.

  10. Light-Directed Ranging System Implementing Single Camera System for Telerobotics Applications

    NASA Technical Reports Server (NTRS)

    Wells, Dennis L. (Inventor); Li, Larry C. (Inventor); Cox, Brian J. (Inventor)

    1997-01-01

    A laser-directed ranging system has utility for use in various fields, such as telerobotics applications and other applications involving physically handicapped individuals. The ranging system includes a single video camera and a directional light source such as a laser mounted on a camera platform, and a remotely positioned operator. In one embodiment, the position of the camera platform is controlled by three servo motors to orient the roll axis, pitch axis and yaw axis of the video cameras, based upon an operator input such as head motion. The laser is offset vertically and horizontally from the camera, and the laser/camera platform is directed by the user to point the laser and the camera toward a target device. The image produced by the video camera is processed to eliminate all background images except for the spot created by the laser. This processing is performed by creating a digital image of the target prior to illumination by the laser, and then eliminating common pixels from the subsequent digital image which includes the laser spot. A reference point is defined at a point in the video frame, which may be located outside of the image area of the camera. The disparity between the digital image of the laser spot and the reference point is calculated for use in a ranging analysis to determine range to the target.

  11. Lumbar posture and trunk muscle activation during a typing task when sitting on a novel dynamic ergonomic chair.

    PubMed

    O'Sullivan, Kieran; McCarthy, Raymond; White, Alison; O'Sullivan, Leonard; Dankaerts, Wim

    2012-01-01

    Low back pain (LBP) is a common musculoskeletal disorder and prolonged sitting often aggravates LBP. A novel dynamic ergonomic chair ('Back App'), which facilitates less hip flexion while sitting on an unstable base has been developed. This study compared lumbar posture and trunk muscle activation on this novel chair with a standard backless office chair. Twelve painfree participants completed a typing task on both chairs. Lumbar posture and trunk muscle activation were collected simultaneously and were analysed using paired t-tests. Sitting on the novel dynamic chair significantly (p < 0.05) reduced both lumbar flexion and the activation of one back muscle (Iliocostalis Lumborum pars Thoracis). The discomfort experienced was mild and was similar (p > 0.05) between chairs. Maintaining lordosis with less muscle activation during prolonged sitting could reduce the fatigue associated with upright sitting postures. Studies with longer sitting durations, and in people with LBP, are required. Sitting on a novel dynamic chair resulted in less lumbar flexion and less back muscle activation than sitting on a standard backless office chair during a typing task among pain-free participants. Facilitating lordotic sitting with less muscle activation may reduce the fatigue and discomfort often associated with lordotic sitting postures.

  12. The Effectiveness of a Web-Based Computer-Tailored Intervention on Workplace Sitting: A Randomized Controlled Trial.

    PubMed

    De Cocker, Katrien; De Bourdeaudhuij, Ilse; Cardon, Greet; Vandelanotte, Corneel

    2016-05-31

    Effective interventions to influence workplace sitting are needed, as office-based workers demonstrate high levels of continued sitting, and sitting too much is associated with adverse health effects. Therefore, we developed a theory-driven, Web-based, interactive, computer-tailored intervention aimed at reducing and interrupting sitting at work. The objective of our study was to investigate the effects of this intervention on objectively measured sitting time, standing time, and breaks from sitting, as well as self-reported context-specific sitting among Flemish employees in a field-based approach. Employees (n=213) participated in a 3-group randomized controlled trial that assessed outcomes at baseline, 1-month follow-up, and 3-month follow-up through self-reports. A subsample (n=122) were willing to wear an activity monitor (activPAL) from Monday to Friday. The tailored group received an automated Web-based, computer-tailored intervention including personalized feedback and tips on how to reduce or interrupt workplace sitting. The generic group received an automated Web-based generic advice with tips. The control group was a wait-list control condition, initially receiving no intervention. Intervention effects were tested with repeated-measures multivariate analysis of variance. The tailored intervention was successful in decreasing self-reported total workday sitting (time × group: P<.001), sitting at work (time × group: P<.001), and leisure time sitting (time × group: P=.03), and in increasing objectively measured breaks at work (time × group: P=.07); this was not the case in the other conditions. The changes in self-reported total nonworkday sitting, sitting during transport, television viewing, and personal computer use, objectively measured total sitting time, and sitting and standing time at work did not differ between conditions. Our results point out the significance of computer tailoring for sedentary behavior and its potential use in public health promotion, as the effects of the tailored condition were superior to the generic and control conditions. Clinicaltrials.gov NCT02672215; http://clinicaltrials.gov/ct2/show/NCT02672215 (Archived by WebCite at http://www.webcitation.org/6glPFBLWv).

  13. Evidence of increasing sedentarism in Mexico City during the last decade: Sitting time prevalence, trends, and associations with obesity and diabetes.

    PubMed

    Medina, Catalina; Tolentino-Mayo, Lizbeth; López-Ridaura, Ruy; Barquera, Simón

    2017-01-01

    Sedentary behaviors such as sitting time are associated with obesity and diabetes independently of total reported physical activity. This study aimed to describe the current sitting time/day prevalence and trends and to examine the association of sitting time with sociodemographic and clinical variables in Mexico City. Two cross-sectional representative surveys in Mexico City were used for this analysis (2006: n = 1148 and 2015: n = 1329). Sedentary behavior questions from the International Physical Activity Questionnaire included time spent sitting on a weekday in the last week or on a Wednesday. Sitting time /day was divided into deciles, and participants in the highest decile (≥ 420 minutes/day) were classified within the high sitting category; others were classified in the low sitting time category. Multivariate logistic regression was used to evaluate the associations of sitting time with sociodemographic and clinical indicators, controlling for confounders and testing for potential interactions. A total of 13.7% (2006) and 14.8% (2015) adults were classified in the highest sitting time category (≥ 420 minutes/day). There was a significant increase in the average sitting time/day between the surveys (216.0 minutes in 2006 vs. 233.3 minutes in 2015, p < 0.001). In 2015, men, those aged 20-49 years, those in low-intensity jobs, students, and those with a high socioeconomic level were more likely to be in the highest sitting time category. Participants with overweight/obesity (OR = 2.37, 95% CI: 1.11, 5.09) and those with high glucose levels (survey finding) (OR = 2.34, 95% CI: 1.04, 5.25) were more likely to report sitting time in the highest category. Sitting time/day prevalence increased 8%, and average daily sitting minutes significantly increased by 8.2% (18 minutes) in the nine-year study period (2006-2015). Current public health policies should consider strategies not only for increasing physical activity levels, but also for reducing sitting time/day among the population as a measure to fight the growing epidemic of obesity and diabetes in Mexico.

  14. Evidence of increasing sedentarism in Mexico City during the last decade: Sitting time prevalence, trends, and associations with obesity and diabetes

    PubMed Central

    Tolentino-Mayo, Lizbeth; López-Ridaura, Ruy; Barquera, Simón

    2017-01-01

    Introduction Sedentary behaviors such as sitting time are associated with obesity and diabetes independently of total reported physical activity. This study aimed to describe the current sitting time/day prevalence and trends and to examine the association of sitting time with sociodemographic and clinical variables in Mexico City. Methods Two cross-sectional representative surveys in Mexico City were used for this analysis (2006: n = 1148 and 2015: n = 1329). Sedentary behavior questions from the International Physical Activity Questionnaire included time spent sitting on a weekday in the last week or on a Wednesday. Sitting time /day was divided into deciles, and participants in the highest decile (≥ 420 minutes/day) were classified within the high sitting category; others were classified in the low sitting time category. Multivariate logistic regression was used to evaluate the associations of sitting time with sociodemographic and clinical indicators, controlling for confounders and testing for potential interactions. Results A total of 13.7% (2006) and 14.8% (2015) adults were classified in the highest sitting time category (≥ 420 minutes/day). There was a significant increase in the average sitting time/day between the surveys (216.0 minutes in 2006 vs. 233.3 minutes in 2015, p < 0.001). In 2015, men, those aged 20–49 years, those in low-intensity jobs, students, and those with a high socioeconomic level were more likely to be in the highest sitting time category. Participants with overweight/obesity (OR = 2.37, 95% CI: 1.11, 5.09) and those with high glucose levels (survey finding) (OR = 2.34, 95% CI: 1.04, 5.25) were more likely to report sitting time in the highest category. Discussion Sitting time/day prevalence increased 8%, and average daily sitting minutes significantly increased by 8.2% (18 minutes) in the nine-year study period (2006–2015). Current public health policies should consider strategies not only for increasing physical activity levels, but also for reducing sitting time/day among the population as a measure to fight the growing epidemic of obesity and diabetes in Mexico. PMID:29194458

  15. Is objectively measured sitting time associated with low back pain? A cross-sectional investigation in the NOMAD study.

    PubMed

    Gupta, Nidhi; Christiansen, Caroline Stordal; Hallman, David M; Korshøj, Mette; Carneiro, Isabella Gomes; Holtermann, Andreas

    2015-01-01

    Studies on the association between sitting time and low back pain (LBP) have found contrasting results. This may be due to the lack of objectively measured sitting time or because socioeconomic confounders were not considered in the analysis. To investigate the association between objectively measured sitting time (daily total, and occupational and leisure-time periods) and LBP among blue-collar workers. Two-hundred-and-one blue-collar workers wore two accelerometers (GT3X+ Actigraph) for up to four consecutive working days to obtain objective measures of sitting time, estimated via Acti4 software. Workers reported their LBP intensity the past month on a scale from 0 (no pain) to 9 (worst imaginable pain) and were categorized into either low (≤ 5) or high (> 5) LBP intensity groups. In the multivariate-adjusted binary logistic regression analysis, total sitting time, and occupational and leisure-time sitting were both modeled as continuous (hours/day) and categorical variables (i.e. low, moderate and high sitting time). The multivariate logistic regression analysis showed a significant positive association between total sitting time (per hour) and high LBP intensity (odds ratio; OR = 1.43, 95%CI = 1.15-1.77, P = 0.01). Similar results were obtained for leisure-time sitting (OR = 1.45, 95%CI = 1.10-1.91, P = 0.01), and a similar but non-significant trend was obtained for occupational sitting time (OR = 1.34, 95%CI 0.99-1.82, P = 0.06). In the analysis on categorized sitting time, high sitting time was positively associated with high LBP for total (OR = 3.31, 95%CI = 1.18-9.28, P = 0.03), leisure (OR = 5.31, 95%CI = 1.57-17.90, P = 0.01), and occupational (OR = 3.26, 95%CI = 0.89-11.98, P = 0.08) periods, referencing those with low sitting time. Sitting time is positively associated with LBP intensity among blue-collar workers. Future studies using a prospective design with objective measures of sitting time are recommended.

  16. Is Objectively Measured Sitting Time Associated with Low Back Pain? A Cross-Sectional Investigation in the NOMAD study

    PubMed Central

    Gupta, Nidhi; Christiansen, Caroline Stordal; Hallman, David M.; Korshøj, Mette; Carneiro, Isabella Gomes; Holtermann, Andreas

    2015-01-01

    Background Studies on the association between sitting time and low back pain (LBP) have found contrasting results. This may be due to the lack of objectively measured sitting time or because socioeconomic confounders were not considered in the analysis. Objectives To investigate the association between objectively measured sitting time (daily total, and occupational and leisure-time periods) and LBP among blue-collar workers. Methods Two-hundred-and-one blue-collar workers wore two accelerometers (GT3X+ Actigraph) for up to four consecutive working days to obtain objective measures of sitting time, estimated via Acti4 software. Workers reported their LBP intensity the past month on a scale from 0 (no pain) to 9 (worst imaginable pain) and were categorized into either low (≤5) or high (>5) LBP intensity groups. In the multivariate-adjusted binary logistic regression analysis, total sitting time, and occupational and leisure-time sitting were both modeled as continuous (hours/day) and categorical variables (i.e. low, moderate and high sitting time). Results The multivariate logistic regression analysis showed a significant positive association between total sitting time (per hour) and high LBP intensity (odds ratio; OR=1.43, 95%CI=1.15-1.77, P=0.01). Similar results were obtained for leisure-time sitting (OR=1.45, 95%CI=1.10-1.91, P=0.01), and a similar but non-significant trend was obtained for occupational sitting time (OR=1.34, 95%CI 0.99-1.82, P=0.06). In the analysis on categorized sitting time, high sitting time was positively associated with high LBP for total (OR=3.31, 95%CI=1.18-9.28, P=0.03), leisure (OR=5.31, 95%CI=1.57-17.90, P=0.01), and occupational (OR=3.26, 95%CI=0.89-11.98, P=0.08) periods, referencing those with low sitting time. Conclusion Sitting time is positively associated with LBP intensity among blue-collar workers. Future studies using a prospective design with objective measures of sitting time are recommended. PMID:25806808

  17. The Effectiveness of a Web-Based Computer-Tailored Intervention on Workplace Sitting: A Randomized Controlled Trial

    PubMed Central

    De Bourdeaudhuij, Ilse; Cardon, Greet; Vandelanotte, Corneel

    2016-01-01

    Background Effective interventions to influence workplace sitting are needed, as office-based workers demonstrate high levels of continued sitting, and sitting too much is associated with adverse health effects. Therefore, we developed a theory-driven, Web-based, interactive, computer-tailored intervention aimed at reducing and interrupting sitting at work. Objective The objective of our study was to investigate the effects of this intervention on objectively measured sitting time, standing time, and breaks from sitting, as well as self-reported context-specific sitting among Flemish employees in a field-based approach. Methods Employees (n=213) participated in a 3-group randomized controlled trial that assessed outcomes at baseline, 1-month follow-up, and 3-month follow-up through self-reports. A subsample (n=122) were willing to wear an activity monitor (activPAL) from Monday to Friday. The tailored group received an automated Web-based, computer-tailored intervention including personalized feedback and tips on how to reduce or interrupt workplace sitting. The generic group received an automated Web-based generic advice with tips. The control group was a wait-list control condition, initially receiving no intervention. Intervention effects were tested with repeated-measures multivariate analysis of variance. Results The tailored intervention was successful in decreasing self-reported total workday sitting (time × group: P<.001), sitting at work (time × group: P<.001), and leisure time sitting (time × group: P=.03), and in increasing objectively measured breaks at work (time × group: P=.07); this was not the case in the other conditions. The changes in self-reported total nonworkday sitting, sitting during transport, television viewing, and personal computer use, objectively measured total sitting time, and sitting and standing time at work did not differ between conditions. Conclusions Our results point out the significance of computer tailoring for sedentary behavior and its potential use in public health promotion, as the effects of the tailored condition were superior to the generic and control conditions. Trial Registration Clinicaltrials.gov NCT02672215; http://clinicaltrials.gov/ct2/show/NCT02672215 (Archived by WebCite at http://www.webcitation.org/6glPFBLWv) PMID:27245789

  18. Fuzzy logic control for camera tracking system

    NASA Technical Reports Server (NTRS)

    Lea, Robert N.; Fritz, R. H.; Giarratano, J.; Jani, Yashvant

    1992-01-01

    A concept utilizing fuzzy theory has been developed for a camera tracking system to provide support for proximity operations and traffic management around the Space Station Freedom. Fuzzy sets and fuzzy logic based reasoning are used in a control system which utilizes images from a camera and generates required pan and tilt commands to track and maintain a moving target in the camera's field of view. This control system can be implemented on a fuzzy chip to provide an intelligent sensor for autonomous operations. Capabilities of the control system can be expanded to include approach, handover to other sensors, caution and warning messages.

  19. Variation in detection among passive infrared triggered-cameras used in wildlife research

    USGS Publications Warehouse

    Damm, Philip E.; Grand, James B.; Barnett, Steven W.

    2010-01-01

    Precise and accurate estimates of demographics such as age structure, productivity, and density are necessary in determining habitat and harvest management strategies for wildlife populations. Surveys using automated cameras are becoming an increasingly popular tool for estimating these parameters. However, most camera studies fail to incorporate detection probabilities, leading to parameter underestimation. The objective of this study was to determine the sources of heterogeneity in detection for trail cameras that incorporate a passive infrared (PIR) triggering system sensitive to heat and motion. Images were collected at four baited sites within the Conecuh National Forest, Alabama, using three cameras at each site operating continuously over the same seven-day period. Detection was estimated for four groups of animals based on taxonomic group and body size. Our hypotheses of detection considered variation among bait sites and cameras. The best model (w=0.99) estimated different rates of detection for each camera in addition to different detection rates for four animal groupings. Factors that explain this variability might include poor manufacturing tolerances, variation in PIR sensitivity, animal behavior, and species-specific infrared radiation. Population surveys using trail cameras with PIR systems must incorporate detection rates for individual cameras. Incorporating time-lapse triggering systems into survey designs should eliminate issues associated with PIR systems.

  20. A Ground-Based Near Infrared Camera Array System for UAV Auto-Landing in GPS-Denied Environment.

    PubMed

    Yang, Tao; Li, Guangpo; Li, Jing; Zhang, Yanning; Zhang, Xiaoqiang; Zhang, Zhuoyue; Li, Zhi

    2016-08-30

    This paper proposes a novel infrared camera array guidance system with capability to track and provide real time position and speed of a fixed-wing Unmanned air vehicle (UAV) during a landing process. The system mainly include three novel parts: (1) Infrared camera array and near infrared laser lamp based cooperative long range optical imaging module; (2) Large scale outdoor camera array calibration module; and (3) Laser marker detection and 3D tracking module. Extensive automatic landing experiments with fixed-wing flight demonstrate that our infrared camera array system has the unique ability to guide the UAV landing safely and accurately in real time. Moreover, the measurement and control distance of our system is more than 1000 m. The experimental results also demonstrate that our system can be used for UAV automatic accurate landing in Global Position System (GPS)-denied environments.

  1. Excessive sitting at work and at home: Correlates of occupational sitting and TV viewing time in working adults.

    PubMed

    Hadgraft, Nyssa T; Lynch, Brigid M; Clark, Bronwyn K; Healy, Genevieve N; Owen, Neville; Dunstan, David W

    2015-09-15

    Recent evidence links sedentary behaviour (or too much sitting) with poorer health outcomes; many adults accumulate the majority of their daily sitting time through occupational sitting and TV viewing. To further the development and targeting of evidence-based strategies there is a need for identification of the factors associated with higher levels of these behaviours. This study examined socio-demographic and health-related correlates of occupational sitting and of combined high levels of occupational sitting/TV viewing time amongst working adults. Participants were attendees of the third wave (2011/12) of the Australian Diabetes, Obesity and Lifestyle (AusDiab) study who worked full-time (≥35 h/week; n = 1,235; 38 % women; mean ± SD age 53 ± 7 years). Logistic and multinomial logistic regression analyses were conducted (separately for women and men) to assess cross-sectional associations of self-reported occupational sitting time (categorised as high/low based on the median) and also the combination of occupational sitting time/TV viewing time (high/low for each outcome), with a number of potential socio-demographic and health-related correlates. Higher levels of occupational sitting (>6 h/day) were associated with higher household income for both genders. Lower levels of occupational sitting were associated with being older (women only); and, for men only, having a blue collar occupation, having a technical/vocational educational attainment, and undertaking more leisure-time physical activity (LTPA). Attributes associated with high levels of both occupational sitting and TV viewing time included white collar occupation (men only), lower levels of LTPA (both genders), higher BMI (men), and higher energy consumption (women). Higher household income (both genders) and professional/managerial occupations (men only) were correlates of high occupational sitting time, relative to low occupational sitting time, while health-related factors (lower LTPA, higher BMI - men, and higher energy consumption - women) were associated with high levels of both occupational sitting and TV viewing time, relative to low occupational sitting and low TV viewing time. These findings suggest possible high-risk groups that may benefit from targeted interventions. Further research is needed on potentially modifiable environmental and social correlates of occupational sitting time, in order to inform workplace initiatives.

  2. Global calibration of multi-cameras with non-overlapping fields of view based on photogrammetry and reconfigurable target

    NASA Astrophysics Data System (ADS)

    Xia, Renbo; Hu, Maobang; Zhao, Jibin; Chen, Songlin; Chen, Yueling

    2018-06-01

    Multi-camera vision systems are often needed to achieve large-scale and high-precision measurement because these systems have larger fields of view (FOV) than a single camera. Multiple cameras may have no or narrow overlapping FOVs in many applications, which pose a huge challenge to global calibration. This paper presents a global calibration method for multi-cameras without overlapping FOVs based on photogrammetry technology and a reconfigurable target. Firstly, two planar targets are fixed together and made into a long target according to the distance between the two cameras to be calibrated. The relative positions of the two planar targets can be obtained by photogrammetric methods and used as invariant constraints in global calibration. Then, the reprojection errors of target feature points in the two cameras’ coordinate systems are calculated at the same time and optimized by the Levenberg–Marquardt algorithm to find the optimal solution of the transformation matrix between the two cameras. Finally, all the camera coordinate systems are converted to the reference coordinate system in order to achieve global calibration. Experiments show that the proposed method has the advantages of high accuracy (the RMS error is 0.04 mm) and low cost and is especially suitable for on-site calibration.

  3. Uav Cameras: Overview and Geometric Calibration Benchmark

    NASA Astrophysics Data System (ADS)

    Cramer, M.; Przybilla, H.-J.; Zurhorst, A.

    2017-08-01

    Different UAV platforms and sensors are used in mapping already, many of them equipped with (sometimes) modified cameras as known from the consumer market. Even though these systems normally fulfil their requested mapping accuracy, the question arises, which system performs best? This asks for a benchmark, to check selected UAV based camera systems in well-defined, reproducible environments. Such benchmark is tried within this work here. Nine different cameras used on UAV platforms, representing typical camera classes, are considered. The focus is laid on the geometry here, which is tightly linked to the process of geometrical calibration of the system. In most applications the calibration is performed in-situ, i.e. calibration parameters are obtained as part of the project data itself. This is often motivated because consumer cameras do not keep constant geometry, thus, cannot be seen as metric cameras. Still, some of the commercial systems are quite stable over time, as it was proven from repeated (terrestrial) calibrations runs. Already (pre-)calibrated systems may offer advantages, especially when the block geometry of the project does not allow for a stable and sufficient in-situ calibration. Especially for such scenario close to metric UAV cameras may have advantages. Empirical airborne test flights in a calibration field have shown how block geometry influences the estimated calibration parameters and how consistent the parameters from lab calibration can be reproduced.

  4. A novel camera localization system for extending three-dimensional digital image correlation

    NASA Astrophysics Data System (ADS)

    Sabato, Alessandro; Reddy, Narasimha; Khan, Sameer; Niezrecki, Christopher

    2018-03-01

    The monitoring of civil, mechanical, and aerospace structures is important especially as these systems approach or surpass their design life. Often, Structural Health Monitoring (SHM) relies on sensing techniques for condition assessment. Advancements achieved in camera technology and optical sensors have made three-dimensional (3D) Digital Image Correlation (DIC) a valid technique for extracting structural deformations and geometry profiles. Prior to making stereophotogrammetry measurements, a calibration has to be performed to obtain the vision systems' extrinsic and intrinsic parameters. It means that the position of the cameras relative to each other (i.e. separation distance, cameras angle, etc.) must be determined. Typically, cameras are placed on a rigid bar to prevent any relative motion between the cameras. This constraint limits the utility of the 3D-DIC technique, especially as it is applied to monitor large-sized structures and from various fields of view. In this preliminary study, the design of a multi-sensor system is proposed to extend 3D-DIC's capability and allow for easier calibration and measurement. The suggested system relies on a MEMS-based Inertial Measurement Unit (IMU) and a 77 GHz radar sensor for measuring the orientation and relative distance of the stereo cameras. The feasibility of the proposed combined IMU-radar system is evaluated through laboratory tests, demonstrating its ability in determining the cameras position in space for performing accurate 3D-DIC calibration and measurements.

  5. Depth Perception In Remote Stereoscopic Viewing Systems

    NASA Technical Reports Server (NTRS)

    Diner, Daniel B.; Von Sydow, Marika

    1989-01-01

    Report describes theoretical and experimental studies of perception of depth by human operators through stereoscopic video systems. Purpose of such studies to optimize dual-camera configurations used to view workspaces of remote manipulators at distances of 1 to 3 m from cameras. According to analysis, static stereoscopic depth distortion decreased, without decreasing stereoscopitc depth resolution, by increasing camera-to-object and intercamera distances and camera focal length. Further predicts dynamic stereoscopic depth distortion reduced by rotating cameras around center of circle passing through point of convergence of viewing axes and first nodal points of two camera lenses.

  6. Multi-color pyrometry imaging system and method of operating the same

    DOEpatents

    Estevadeordal, Jordi; Nirmalan, Nirm Velumylum; Tralshawala, Nilesh; Bailey, Jeremy Clyde

    2017-03-21

    A multi-color pyrometry imaging system for a high-temperature asset includes at least one viewing port in optical communication with at least one high-temperature component of the high-temperature asset. The system also includes at least one camera device in optical communication with the at least one viewing port. The at least one camera device includes a camera enclosure and at least one camera aperture defined in the camera enclosure, The at least one camera aperture is in optical communication with the at least one viewing port. The at least one camera device also includes a multi-color filtering mechanism coupled to the enclosure. The multi-color filtering mechanism is configured to sequentially transmit photons within a first predetermined wavelength band and transmit photons within a second predetermined wavelength band that is different than the first predetermined wavelength band.

  7. Total and domain-specific sitting time among employees in desk-based work settings in Australia.

    PubMed

    Bennie, Jason A; Pedisic, Zeljko; Timperio, Anna; Crawford, David; Dunstan, David; Bauman, Adrian; van Uffelen, Jannique; Salmon, Jo

    2015-06-01

    To describe the total and domain-specific daily sitting time among a sample of Australian office-based employees. In April 2010, paper-based surveys were provided to desk-based employees (n=801) in Victoria, Australia. Total daily and domain-specific (work, leisure-time and transport-related) sitting time (minutes/day) were assessed by validated questionnaires. Differences in sitting time were examined across socio-demographic (age, sex, occupational status) and lifestyle characteristics (physical activity levels, body mass index [BMI]) using multiple linear regression analyses. The median (95% confidence interval [CI]) of total daily sitting time was 540 (531-557) minutes/day. Insufficiently active adults (median=578 minutes/day, [95%CI: 564-602]), younger adults aged 18-29 years (median=561 minutes/day, [95%CI: 540-577]) reported the highest total daily sitting times. Occupational sitting time accounted for almost 60% of total daily sitting time. In multivariate analyses, total daily sitting time was negatively associated with age (unstandardised regression coefficient [B]=-1.58, p<0.001) and overall physical activity (minutes/week) (B=-0.03, p<0.001) and positively associated with BMI (B=1.53, p=0.038). Desk-based employees reported that more than half of their total daily sitting time was accrued in the work setting. Given the high contribution of occupational sitting to total daily sitting time among desk-based employees, interventions should focus on the work setting. © 2014 Public Health Association of Australia.

  8. Who is at risk of chronic disease? Associations between risk profiles of physical activity, sitting and cardio-metabolic disease in Australian adults.

    PubMed

    Engelen, Lina; Gale, Joanne; Chau, Josephine Y; Hardy, Louise L; Mackey, Martin; Johnson, Nathan; Shirley, Debra; Bauman, Adrian

    2017-04-01

    To examine the associations of physical activity (PA) and sitting time (sit) with cardio-metabolic diseases. Cross-sectional data from the Australian National Nutrition and Physical Activity Survey 2011-2012 (n=9,435) were used to classify adults into low and high risk groups based on their physical activity and sitting behaviour profiles. Logistic regression models examined associations between low and high risk classifications (high PA-low sit; high PA-high sit; low PA-low sit; low PA-high sit;) and socio-demographic factors, and associations between low and high risk classifications and the prevalence of cardiovascular disease, Type 2 diabetes and metabolic syndrome. These results characterise chronic disease risk based on both physical activity and sitting behaviour. Adults with the highest risk lifestyle behaviour pattern (low PA-high sit) tended to be middle aged, male, at greater social disadvantage, smoke, report fair health, be abdominally obese and employed in administrative and driver occupations. These individuals had a substantially greater risk of cardiovascular disease and metabolic syndrome (OR=1.41, 95% CI 1.13, 1.75; OR= 2.37, 95% CI 1.63, 3.45, respectively). The findings highlight the importance of both sufficient physical activity and low sitting time for cardio-metabolic health. Implications for public health: Primary prevention focus should consider physical activity and reduced sitting time as well as provision of relevant advice for cardio-metabolic health. © 2017 The Authors.

  9. Do Sitting, Standing, or Treadmill Desks Impact Psychobiological Indicators of Work Productivity?

    PubMed

    Gilson, Nicholas D; Hall, Caitlin; Renton, Angela; Ng, Norman; von Hippel, William

    2017-10-01

    This pilot study investigated the links between psychobiological indicators of work productivity, prolonged desk sitting, and conditions whereby office workers were able to interrupt sitting using a sit-stand or treadmill desk. Twenty participants visited our laboratory and completed their own desk work in counterbalanced sit-only, sit-stand (Varidesk Pro Plus 48™), and sit-walk conditions (Infiniti TR1200-DTS™). Steady-state visually evoked potentials calculated from electroencephalography recordings during a set task at the end of the workday assessed attentional resource. Salivary cortisol samples were taken during the morning and afternoon to measure stress response. Within-subject analyses were used to compare work productivity indicators relative to condition. No significant differences in mean steady-state visually evoked potential amplitude were observed, although attentional resource allocation was found to be the most effective following the sit-stand [1.01 (0.46) μV] compared with the sit-walk [0.9 (0.28) μV] and sit-only [0.91 (0.32) μV] conditions. The mean magnitude of decrease in cortisol was most apparent when workers used treadmill (1.5 nmol/L; P = .007) and sit-stand (1.6 nmol/L; P = .001) desks, and least evident in the sit-only condition (1.0 nmol/L; P = .146). The findings highlight the potential benefits of standing or active deskwork to the allocation of attentional resources and the regulation of stress.

  10. Relationship between built environment attributes and physical function in Japanese community-dwelling older adults.

    PubMed

    Soma, Yuki; Tsunoda, Kenji; Kitano, Naruki; Jindo, Takashi; Tsuji, Taishi; Saghazadeh, Mahshid; Okura, Tomohiro

    2017-03-01

    To explore the relationships between the built environment and older adults' physical function. The present cross-sectional study carried out in 2010-2012 used data drawn from 509 community-dwelling older adults aged 65-86 years living in Kasama City, a Japanese rural region. We evaluated physical function with the following performance tests: grip strength, sit-to-stand, timed up & go and walking speed. Using geographic information systems, we measured population density and the number of destinations related to daily life, community centers, medical facilities and recreational facilities within participants' neighborhoods. After adjusting for potential confounders, we found lower population density was related to poor performance of sit-to-stand and walking speed in both sexes, and grip strength in women (trend P < 0.05). A lower number of daily life-related destinations was related to poor performance of sit-to-stand and walking speed in men, and grip strength and sit-to-stand in women. Similarly, the number of community centers was related to walking speed in both sexes. The number of medical and recreational facilities was also related to some physical performance in both sexes. A lower land use mix score, calculated by principal component analysis, was related to lower performance of sit-to-stand and walking speed in men, and grip strength and sit-to-stand in women. The present study suggests that, although there are some sex differences, low population density, land use mix, and fewer daily life-related destinations, community centers, medical facilities and recreational facilities are negative determinants of physical function. Geriatr Gerontol Int 2017; 17: 382-390. © 2016 Japan Geriatrics Society.

  11. Development of adaptive sensorimotor control in infant sitting posture.

    PubMed

    Chen, Li-Chiou; Jeka, John; Clark, Jane E

    2016-03-01

    A reliable and adaptive relationship between action and perception is necessary for postural control. Our understanding of how this adaptive sensorimotor control develops during infancy is very limited. This study examines the dynamic visual-postural relationship during early development. Twenty healthy infants were divided into 4 developmental groups (each n=5): sitting onset, standing alone, walking onset, and 1-year post-walking. During the experiment, the infant sat independently in a virtual moving-room in which anterior-posterior oscillations of visual motion were presented using a sum-of-sines technique with five input frequencies (from 0.12 to 1.24 Hz). Infants were tested in five conditions that varied in the amplitude of visual motion (from 0 to 8.64 cm). Gain and phase responses of infants' postural sway were analyzed. Our results showed that infants, from a few months post-sitting to 1 year post-walking, were able to control their sitting posture in response to various frequency and amplitude properties of the visual motion. Infants showed an adult-like inverted-U pattern for the frequency response to visual inputs with the highest gain at 0.52 and 0.76 Hz. As the visual motion amplitude increased, the gain response decreased. For the phase response, an adult-like frequency-dependent pattern was observed in all amplitude conditions for the experienced walkers. Newly sitting infants, however, showed variable postural behavior and did not systemically respond to the visual stimulus. Our results suggest that visual-postural entrainment and sensory re-weighting are fundamental processes that are present after a few months post sitting. Sensorimotor refinement during early postural development may result from the interactions of improved self-motion control and enhanced perceptual abilities. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Ergonomic design of a barber's workstation.

    PubMed

    al-Haboubi, M H; Baig, A

    1997-06-01

    Long hours of work while standing have been known to cause health problems for humans. Such professions include that of the barber. A survey was conducted of barbers from different barber shops in Saudi Arabia to determine their discomfort level. A prototype workstation was then designed and constructed in which the barber sits and performs work. The workstation was tested by nine barbers in the Human Factors Laboratory in the Systems Engineering Department at King Fahd University of Petroleum and Minerals. These barbers were among those surveyed earlier in their shops. Their discomfort level was again taken and an experiment was conducted to design the shape of the footrest. The discomfort levels obtained while standing and sitting were statistically analysed. From the results, it was concluded that the mean of the discomfort levels while standing is significantly (alpha = 0.01) higher than that while sitting.

  13. Single-camera stereo-digital image correlation with a four-mirror adapter: optimized design and validation

    NASA Astrophysics Data System (ADS)

    Yu, Liping; Pan, Bing

    2016-12-01

    A low-cost, easy-to-implement but practical single-camera stereo-digital image correlation (DIC) system using a four-mirror adapter is established for accurate shape and three-dimensional (3D) deformation measurements. The mirrors assisted pseudo-stereo imaging system can convert a single camera into two virtual cameras, which view a specimen from different angles and record the surface images of the test object onto two halves of the camera sensor. To enable deformation measurement in non-laboratory conditions or extreme high temperature environments, an active imaging optical design, combining an actively illuminated monochromatic source with a coupled band-pass optical filter, is compactly integrated to the pseudo-stereo DIC system. The optical design, basic principles and implementation procedures of the established system for 3D profile and deformation measurements are described in detail. The effectiveness and accuracy of the established system are verified by measuring the profile of a regular cylinder surface and displacements of a translated planar plate. As an application example, the established system is used to determine the tensile strains and Poisson's ratio of a composite solid propellant specimen during stress relaxation test. Since the established single-camera stereo-DIC system only needs a single camera and presents strong robustness against variations in ambient light or the thermal radiation of a hot object, it demonstrates great potential in determining transient deformation in non-laboratory or high-temperature environments with the aid of a single high-speed camera.

  14. Mitigation of Atmospheric Effects on Imaging Systems

    DTIC Science & Technology

    2004-03-31

    focal length. The imaging system had two cameras: an Electrim camera sensitive in the visible (0.6 µ m) waveband and an Amber QWIP infrared camera...sensitive in the 9–micron region. The Amber QWIP infrared camera had 256x256 pixels, pixel pitch 38 mµ , focal length of 1.8 m, FOV of 5.4 x5.4 mr...each day. Unfortunately, signals from the different read ports of the Electrim camera picked up noise on their way to the digitizer, and this resulted

  15. Predictors of severe trunk postures among short-haul truck drivers during non-driving tasks: an exploratory investigation involving video-assessment and driver behavioural self-monitoring.

    PubMed

    Olson, R; Hahn, D I; Buckert, A

    2009-06-01

    Short-haul truck (lorry) drivers are particularly vulnerable to back pain and injury due to exposure to whole body vibration, prolonged sitting and demanding material handling tasks. The current project reports the results of video-based assessments (711 stops) and driver behavioural self-monitoring (BSM) (385 stops) of injury hazards during non-driving work. Participants (n = 3) worked in a trailer fitted with a camera system during baseline and BSM phases. Descriptive analyses showed that challenging customer environments and non-standard ingress/egress were prevalent. Statistical modelling of video-assessment results showed that each instance of manual material handling increased the predicted mean for severe trunk postures by 7%, while customer use of a forklift, moving standard pallets and moving non-standard pallets decreased predicted means by 12%, 20% and 22% respectively. Video and BSM comparisons showed that drivers were accurate at self-monitoring frequent environmental conditions, but less accurate at monitoring trunk postures and rare work events. The current study identified four predictors of severe trunk postures that can be modified to reduce risk of injury among truck drivers and showed that workers can produce reliable self-assessment data with BSM methods for frequent and easily discriminated events environmental.

  16. Hubble "Crane-s" in for a Closer Look at a Galaxy

    NASA Image and Video Library

    2017-12-08

    In 1900, astronomer Joseph Lunt made a discovery: Peering through a telescope at Cape Town Observatory, the British–South African scientist spotted this beautiful sight in the southern constellation of Grus (The Crane): a barred spiral galaxy now named IC 5201. Over a century later, the galaxy is still of interest to astronomers. For this image, the NASA/ESA Hubble Space Telescope used its Advanced Camera for Surveys (ACS) to produce a beautiful and intricate image of the galaxy. Hubble’s ACS can resolve individual stars within other galaxies, making it an invaluable tool to explore how various populations of stars sprang to life, evolved, and died throughout the cosmos. IC 5201 sits over 40 million light-years away from us. As with two thirds of all the spirals we see in the Universe — including the Milky Way — the galaxy has a bar of stars slicing through its center. Credit: ESA/Hubble & NASA NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram

  17. Autocalibration of a projector-camera system.

    PubMed

    Okatani, Takayuki; Deguchi, Koichiro

    2005-12-01

    This paper presents a method for calibrating a projector-camera system that consists of multiple projectors (or multiple poses of a single projector), a camera, and a planar screen. We consider the problem of estimating the homography between the screen and the image plane of the camera or the screen-camera homography, in the case where there is no prior knowledge regarding the screen surface that enables the direct computation of the homography. It is assumed that the pose of each projector is unknown while its internal geometry is known. Subsequently, it is shown that the screen-camera homography can be determined from only the images projected by the projectors and then obtained by the camera, up to a transformation with four degrees of freedom. This transformation corresponds to arbitrariness in choosing a two-dimensional coordinate system on the screen surface and when this coordinate system is chosen in some manner, the screen-camera homography as well as the unknown poses of the projectors can be uniquely determined. A noniterative algorithm is presented, which computes the homography from three or more images. Several experimental results on synthetic as well as real images are shown to demonstrate the effectiveness of the method.

  18. Cross-sectional Examination of Long-term Access to Sit-Stand Desks in a Professional Office Setting.

    PubMed

    Carr, Lucas J; Swift, Maggie; Ferrer, Alex; Benzo, Roberto

    2016-01-01

    Prolonged sedentary behavior is an independent risk factor for many negative health outcomes. Although many employers have begun introducing sit-stand desks as means of reducing employee's occupational sitting time, few studies have examined the impact of prolonged access to such desks on sitting/standing time or cardiometabolic outcomes. The present study compared occupational sedentary/physical activity behaviors and cardiometabolic biomarkers among employees with long-term access to traditional sitting and sit-stand desks. This study used a naturalistic, cross-sectional study design. Occupational sedentary and physical activity behaviors and cardiometabolic health outcomes were collected in a controlled laboratory between February and June 2014. Data were analyzed in September 2014. Adults working in full-time sedentary desk jobs who reported having either a sit-stand desk (n=31) or standard sitting desk (n=38) for a minimum of 6 months were recruited. Employees with sit-stand desks sat less (p=0.02) and stood more at work (p=0.01) compared with employees with sitting desks. Significant inverse correlations were observed between several occupational physical activity outcomes (walking time, steps at work) and cardiometabolic risk factors (systolic blood pressure, weight, lean mass, BMI) over the entire sample. Employees with long-term access to sit-stand desks sat less and stood more compared with employees with sitting desks. These findings hold public health significance, as sit-stand desks represent a potentially sustainable approach for reducing sedentary behavior among the large, growing number of sedentary workers at increased risk for sedentariness-related pathologies. Copyright © 2016 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  19. Why Women Sit: Determinants of Leisure Sitting Time for Working Women.

    PubMed

    Walsh, Shana M; Umstattd Meyer, M Renée; Stamatis, Andreas; Morgan, Grant B

    2015-01-01

    Sedentary behavior is associated with negative health consequences independent of physical activity levels. Evidence suggests the work environment promotes sedentary behavior regardless of sector, and that employees with occupations requiring longer sitting times differ only marginally in leisure sitting time from those with more active occupations. Because physical activity opportunities may be limited across many work settings, leisure sedentary time may be more easily replaced with physical activity. Understanding correlates of leisure sedentary behaviors could inform interventions, specifically for women who are among the least active in America. Female employees at two universities completed online surveys (n = 156; mean age, 45.12 [SD = 12.5]; mean BMI, 26.7 kg/m(2) [SD = 5.9]; mean work hours/week, 43.7 [SD = 9.4]). Bivariate correlations and two hierarchical regression analyses were conducted to examine personal and behavioral correlates of weekday and weekend leisure sitting time. Final regression models revealed that greater weekday leisure sitting time (R(2) = 0.307) was related with being older (p = .006), having fewer children (p = .001), self-reporting poorer health (p = .006), and greater weekend sitting time (p < .001). Greater weekend leisure sitting time (R(2) = 0.261) was related with greater work-related sitting time (p = .020) and greater weekday leisure sitting time (p < .001). Physical activity was not related with weekday or weekend leisure sitting time. The most prominent correlates of leisure sitting time were other types of sedentary behaviors. This suggests that sedentary time in one segment of life predicts time spent sitting in other areas of life. Future interventions should target decreasing sedentary behaviors during leisure time specifically, in addition to increasing physical activity behavior. Copyright © 2015 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  20. Work engagement and its association with occupational sitting time: results from the Stormont study.

    PubMed

    Munir, Fehmidah; Houdmont, Jonathan; Clemes, Stacy; Wilson, Kelly; Kerr, Robert; Addley, Ken

    2015-01-29

    Evidence suggests that poor health outcomes and poor work-related health outcomes such as sickness presenteeism are associated with excessive sitting at work. Studies have yet to investigate the relationship between work engagement and occupational sitting. Work engagement is considered to be an important predictor of work-related well-being. We investigated the relationship between and self-reported work engagement and high occupational sitting time in Northern Ireland Civil Service (NICS) office-based workers. A cohort of 4436 NICS office-workers (1945 men and 2491 women) completed a questionnaire measuring work engagement and occupational sitting time. Logistic regression analyses were used to test the associations between work engagement and occupational sitting times. Compared to women, men reported lower mean occupational sitting time (385.7 minutes/day; s.d. = 1.9; versus 362.4 minutes/day; s.d. =2.5; p < .0001). After adjusting for confounding variables, men with high work engagement of vigor (OR = 0.49, 95% CI 0.34-0.98) and dedication (OR 0.68 95% CI 0.47-0.98) were less likely to have prolonged sitting time. Women with high work engagement of vigor (OR = 0.62, 95% CI 0.45-0.84) were also less likely to have prolonged occupational sitting times. In contrast, women with high absorption (OR = 1.29, 95% CI 1.01-1.65) were more likely to have prolonged sitting times. Being actively engaged in one's work is associated with lower occupational sitting times for men (vigor and dedication) and to a limited extent for women (vigor only). This suggests that interventions such as introducing sit-stand workstations to reduce sitting times, may be beneficial for work engagement.

  1. Perspective on the combined use of an independent transgenic sexing and a multifactorial reproductive sterility system to avoid resistance development against transgenic Sterile Insect Technique approaches

    PubMed Central

    2014-01-01

    Background The Sterile Insect Technique (SIT) is an accepted species-specific genetic control approach that acts as an insect birth control measure, which can be improved by biotechnological engineering to facilitate its use and widen its applicability. First transgenic insects carrying a single killing system have already been released in small scale trials. However, to evade resistance development to such transgenic approaches, completely independent ways of transgenic killing should be established and combined. Perspective Most established transgenic sexing and reproductive sterility systems are based on the binary tTA expression system that can be suppressed by adding tetracycline to the food. However, to create 'redundant killing' an additional independent conditional expression system is required. Here we present a perspective on the use of a second food-controllable binary expression system - the inducible Q system - that could be used in combination with site-specific recombinases to generate independent transgenic killing systems. We propose the combination of an already established transgenic embryonic sexing system to meet the SIT requirement of male-only releases based on the repressible tTA system together with a redundant male-specific reproductive sterility system, which is activated by Q-system controlled site-specific recombination and is based on a spermatogenesis-specifically expressed endonuclease acting on several species-specific target sites leading to chromosome shredding. Conclusion A combination of a completely independent transgenic sexing and a redundant reproductive male sterility system, which do not share any active components and mediate the induced lethality by completely independent processes, would meet the 'redundant killing' criteria for suppression of resistance development and could therefore be employed in large scale long-term suppression programs using biotechnologically enhanced SIT. PMID:25471733

  2. ACT-Vision: active collaborative tracking for multiple PTZ cameras

    NASA Astrophysics Data System (ADS)

    Broaddus, Christopher; Germano, Thomas; Vandervalk, Nicholas; Divakaran, Ajay; Wu, Shunguang; Sawhney, Harpreet

    2009-04-01

    We describe a novel scalable approach for the management of a large number of Pan-Tilt-Zoom (PTZ) cameras deployed outdoors for persistent tracking of humans and vehicles, without resorting to the large fields of view of associated static cameras. Our system, Active Collaborative Tracking - Vision (ACT-Vision), is essentially a real-time operating system that can control hundreds of PTZ cameras to ensure uninterrupted tracking of target objects while maintaining image quality and coverage of all targets using a minimal number of sensors. The system ensures the visibility of targets between PTZ cameras by using criteria such as distance from sensor and occlusion.

  3. The Defrosting South

    NASA Technical Reports Server (NTRS)

    2005-01-01

    20 August 2005 This Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows varied springtime patterns formed in defrosting, seasonal carbon dioxide frost in the south polar region of Mars. The feature sporting an outline of dark spots and an interior of smaller, closely-spaced dark spots and dark-outlined polygons is a patch of windblown or wind-eroded sand that was covered by carbon dioxide frost during the previous autumn and winter. The fainter, larger polygon pattern on either side of the patch of defrosting sand is formed in the substrate upon which the sand patch is sitting. Polygonal forms such as these might indicate the presence of ice below the surface.

    Location near: 79.6oS, 125.0oW Image width: width: 3 km (1.9 mi) Illumination from: upper left Season: Southern Spring

  4. Undersea research vehicle for 20,000-ft depths

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1985-05-01

    This article describes the design and operation of a remotely operated underwater vehicle called RUM III. The vehicle is capable of working to depths of 20,000 feet and is designed to do more work at greater depths than any other unmanned research vehicle. RUM III is about the size of a compact car and its design provides deep ocean research capabilities now only available with manned submersibles, and does so without the limitations of manned devices. It is suitable for a variety of geological, geophysical and ecological studies, and can also be used by scientists to conduct detailed investigations inmore » regions of the ocean floor that are relatively easy to see with cameras and sonar, but difficult to sample directly because of hostile deep-sea environments. RUM III is light enough to sit and maneuver on soft ocean-bottom sediments.« less

  5. Topographic Ceres Map With Crater Names

    NASA Image and Video Library

    2015-07-28

    This color-coded map from NASA Dawn mission shows the highs and lows of topography on the surface of dwarf planet Ceres. It is labeled with names of features approved by the International Astronomical Union. Occator, the mysterious crater containing Ceres' mysterious bright spots, is named after the Roman agriculture deity of harrowing, a method of leveling soil. They retain their bright appearance in this map, although they are color-coded in the same green elevation of the crater floor in which they sit. The color scale extends about 5 miles (7.5 kilometers) below the surface in indigo to 5 miles (7.5 kilometers) above the surface in white. The topographic map was constructed from analyzing images from Dawn's framing camera taken from varying sun and viewing angles. The map was combined with an image mosaic of Ceres and projected as an simple cylindrical projection. http://photojournal.jpl.nasa.gov/catalog/PIA19606

  6. Boulder Track

    NASA Technical Reports Server (NTRS)

    2003-01-01

    MGS MOC Release No. MOC2-408, 1 July 2003

    If a boulder rolls down a slope on an uninhabited planet, does it make a sound? While we do not know the sound made by a boulder rolling down a slope in the martian region of Gordii Dorsum, we do know that it made an impression. This full-resolution Mars Global Surveyor (MGS) Mars Orbiter Camera (MOC) image shows a series of depressions made on a dust-mantled slope as a boulder rolled down it, sometime in the recent past. The boulder track is located just right of center in this picture. The boulder sits at the end of the track. This picture was acquired in May 2003; it is located near 11.2oN, 147.8oW. North is toward the lower left, sunlight illuminates the scene from the right. The picture covers an area only 810 meters (about 886 yards) across.

  7. Apollo 16 lunar module "Orion" photographed from distance during EVA

    NASA Image and Video Library

    1972-04-23

    AS16-116-18678 (23 April 1972) --- A view from the moving Apollo 16 Lunar Roving Vehicle (LRV) as the crew men headed "home" at the end of the mission's third and final extravehicular activity (EVA). Astronaut John W. Young called attention to the series of block fields between the Lunar Module (LM) and LRV. Young also noted that, "The LM was obviously sitting in the only flat place around." Stone Mountain stretches about half way across the background. The high gain antenna and the RCA television camera on the LRV are in the foreground. While astronauts Young, commander; and Charles M. Duke Jr., lunar module pilot; descended in the Apollo 16 LM "Orion" to explore the Descartes highlands landing site on the moon, astronaut Thomas K. Mattingly II, command module pilot, remained with the Command and Service Modules (CSM) "Casper" in lunar orbit.

  8. Traffic monitoring with distributed smart cameras

    NASA Astrophysics Data System (ADS)

    Sidla, Oliver; Rosner, Marcin; Ulm, Michael; Schwingshackl, Gert

    2012-01-01

    The observation and monitoring of traffic with smart visions systems for the purpose of improving traffic safety has a big potential. Today the automated analysis of traffic situations is still in its infancy--the patterns of vehicle motion and pedestrian flow in an urban environment are too complex to be fully captured and interpreted by a vision system. 3In this work we present steps towards a visual monitoring system which is designed to detect potentially dangerous traffic situations around a pedestrian crossing at a street intersection. The camera system is specifically designed to detect incidents in which the interaction of pedestrians and vehicles might develop into safety critical encounters. The proposed system has been field-tested at a real pedestrian crossing in the City of Vienna for the duration of one year. It consists of a cluster of 3 smart cameras, each of which is built from a very compact PC hardware system in a weatherproof housing. Two cameras run vehicle detection and tracking software, one camera runs a pedestrian detection and tracking module based on the HOG dectection principle. All 3 cameras use sparse optical flow computation in a low-resolution video stream in order to estimate the motion path and speed of objects. Geometric calibration of the cameras allows us to estimate the real-world co-ordinates of detected objects and to link the cameras together into one common reference system. This work describes the foundation for all the different object detection modalities (pedestrians, vehicles), and explains the system setup, tis design, and evaluation results which we have achieved so far.

  9. The effect of a sit-stand workstation intervention on daily sitting, standing and physical activity: protocol for a 12 month workplace randomised control trial.

    PubMed

    Hall, Jennifer; Mansfield, Louise; Kay, Tess; McConnell, Alison K

    2015-02-15

    A lack of physical activity and excessive sitting can contribute to poor physical health and wellbeing. The high percentage of the UK adult population in employment, and the prolonged sitting associated with desk-based office-work, make these workplaces an appropriate setting for interventions to reduce sedentary behaviour and increase physical activity. This pilot study aims to determine the effect of an office-based sit-stand workstation intervention, compared with usual desk use, on daily sitting, standing and physical activity, and to examine the factors that underlie sitting, standing and physical activity, within and outside, the workplace. A randomised control trial (RCT) comparing the effects of a sit-stand workstation only and a multi-component sit-stand workstation intervention, with usual desk-based working practice (no sit-stand workstation) will be conducted with office workers across two organisations, over a 12 month period (N = 30). The multicomponent intervention will comprise organisational, environmental and individual elements. Objective data will be collected at baseline, and after 2-weeks, 3-months, 6-months and 12-months of the intervention. Objective measures of sitting, standing, and physical activity will be made concurrently (ActivPAL3™ and ActiGraph (GT3X+)). Activity diaries, ethnographic participant observation, and interviews with participants and key organisational personnel will be used to elicit understanding of the influence of organisational culture on sitting, standing and physical activity behaviour in the workplace. This study will be the first long-term sit-stand workstation intervention study utilising an RCT design, and incorporating a comprehensive process evaluation. The study will generate an understanding of the factors that encourage and restrict successful implementation of sit-stand workstation interventions, and will help inform future occupational wellbeing policy and practice. Other strengths include the objective measurement of physical activity during both work and non-work hours. Clinicaltrials.gov identifier NCT02172599, 22nd June 2014.

  10. Automatic lightning detection and photographic system

    NASA Technical Reports Server (NTRS)

    Wojtasinski, R. J.; Holley, L. D.; Gray, J. L.; Hoover, R. B. (Inventor)

    1972-01-01

    A system is presented for monitoring and recording lightning strokes within a predetermined area with a camera having an electrically operated shutter with means for advancing the film in the camera after activating the shutter. The system includes an antenna for sensing lightning strikes which, in turn, generates a signal that is fed to an electronic circuit which generates signals for operating the shutter of the camera. Circuitry is provided for preventing activation of the shutter as the film in the camera is being advanced.

  11. Airborne ballistic camera tracking systems

    NASA Technical Reports Server (NTRS)

    Redish, W. L.

    1976-01-01

    An operational airborne ballistic camera tracking system was tested for operational and data reduction feasibility. The acquisition and data processing requirements of the system are discussed. Suggestions for future improvements are also noted. A description of the data reduction mathematics is outlined. Results from a successful reentry test mission are tabulated. The test mission indicated that airborne ballistic camera tracking systems are feasible.

  12. Development of an Extra-vehicular (EVA) Infrared (IR) Camera Inspection System

    NASA Technical Reports Server (NTRS)

    Gazarik, Michael; Johnson, Dave; Kist, Ed; Novak, Frank; Antill, Charles; Haakenson, David; Howell, Patricia; Pandolf, John; Jenkins, Rusty; Yates, Rusty

    2006-01-01

    Designed to fulfill a critical inspection need for the Space Shuttle Program, the EVA IR Camera System can detect crack and subsurface defects in the Reinforced Carbon-Carbon (RCC) sections of the Space Shuttle s Thermal Protection System (TPS). The EVA IR Camera performs this detection by taking advantage of the natural thermal gradients induced in the RCC by solar flux and thermal emission from the Earth. This instrument is a compact, low-mass, low-power solution (1.2cm3, 1.5kg, 5.0W) for TPS inspection that exceeds existing requirements for feature detection. Taking advantage of ground-based IR thermography techniques, the EVA IR Camera System provides the Space Shuttle program with a solution that can be accommodated by the existing inspection system. The EVA IR Camera System augments the visible and laser inspection systems and finds cracks and subsurface damage that is not measurable by the other sensors, and thus fills a critical gap in the Space Shuttle s inspection needs. This paper discusses the on-orbit RCC inspection measurement concept and requirements, and then presents a detailed description of the EVA IR Camera System design.

  13. Na+-dependent and Na+-independent betaine transport across the apical membrane of rat renal epithelium.

    PubMed

    Cano, Mercedes; Calonge, María L; Ilundáin, Anunciación A

    2015-10-01

    The low renal excretion of betaine indicates that the kidney efficiently reabsorbs the betaine filtered by the glomeruli but the mechanisms involved in such a process have been scarcely investigated. We have detected concentrative and non-concentrative betaine transport activity in brush-border membrane vesicles (BBMV) from rat renal cortex and medulla. The concentrative system is the Sodium/Imino-acid Transporter 1 (SIT1) because it is Na+- and Cl--dependent, electrogenic and is inhibited by an anti-SIT1 antibody. Its apparent affinity constant for betaine, Kt, is 1.1±0.5 mM and its maximal transport velocity, Vmax, 0.5±0.1 nmol betaine/mg protein/s. Inhibitors of the Na+/Cl-/betaine uptake are L-proline (75%) and cold betaine, L-carnitine and choline (40-60%). Neither creatine, TEA, taurine, β-alanine, GABA nor glycine significantly inhibited Na+/Cl-/betaine uptake. The non-concentrative betaine transport system is Na+- and H+-independent, electroneutral, with a Kt for betaine of 47±7 μM and a Vmax of 7.8±1 pmol betaine/mg protein/s. Its transport activity is nearly abolished by betaine, followed by L-carnitine (70-80%) and proline (40-50%), but a difference from the Na+/Cl-/betaine transport is that it is inhibited by TEA (approx. 50%) and unaffected by choline. The underlying carrier functions as an antiporter linking betaine entry into the BBMV with the efflux of either L-carnitine or betaine, an exchange unaffected by the anti-SIT1 antibody. As far as we know this is the first work reporting that betaine crosses the apical membrane of rat renal epithelium by SIT1 and by a Na+- and H+-independent transport system. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Feasibility and acceptability of reducing workplace sitting time: a qualitative study with Australian office workers.

    PubMed

    Hadgraft, Nyssa T; Brakenridge, Charlotte L; LaMontagne, Anthony D; Fjeldsoe, Brianna S; Lynch, Brigid M; Dunstan, David W; Owen, Neville; Healy, Genevieve N; Lawler, Sheleigh P

    2016-09-05

    Office workers spend a large proportion of their working hours sitting. This may contribute to an increased risk of chronic disease and premature mortality. While there is growing interest in workplace interventions targeting prolonged sitting, few qualitative studies have explored workers' perceptions of reducing occupational sitting outside of an intervention context. This study explored barriers to reducing office workplace sitting, and the feasibility and acceptability of strategies targeting prolonged sitting in this context. Semi-structured interviews were conducted with a convenience sample of 20 office workers (50 % women), including employees and managers, in Melbourne, Australia. The three organisations (two large, and one small organisation) were from retail, health and IT industries and had not implemented any formalised approaches to sitting reduction. Questions covered barriers to reducing sitting, the feasibility of potential strategies aimed at reducing sitting, and perceived effects on productivity. Interviews were audiotaped and transcribed verbatim. Data were analysed using thematic analysis. Participants reported spending most (median: 7.2 h) of their working hours sitting. The nature of computer-based work and exposure to furniture designed for a seated posture were considered to be the main factors influencing sitting time. Low cost strategies, such as standing meetings and in-person communication, were identified as feasible ways to reduce sitting time and were also perceived to have potential productivity benefits. However, social norms around appropriate workplace behaviour and workload pressures were perceived to be barriers to uptake of these strategies. The cost implications of height-adjustable workstations influenced perceptions of feasibility. Managers noted the need for an evidence-based business case supporting action on prolonged sitting, particularly in the context of limited resources and competing workplace health priorities. While a number of low-cost approaches to reduce workplace sitting are perceived to be feasible and acceptable in the office workplace, factors such as work demands and the organisational social context may still act as barriers to greater uptake. Building a supportive organisational culture and raising awareness of the adverse health effects of prolonged sitting may be important for improving individual-level and organisational-level motivation for change.

  15. Influence of dietary nitrate supplementation on physiological and muscle metabolic adaptations to sprint interval training

    PubMed Central

    Thompson, Christopher; Wylie, Lee J.; Blackwell, Jamie R.; Fulford, Jonathan; Black, Matthew I.; Kelly, James; McDonagh, Sinead T. J.; Carter, James; Bailey, Stephen J.; Vanhatalo, Anni

    2017-01-01

    We hypothesized that 4 wk of dietary nitrate supplementation would enhance exercise performance and muscle metabolic adaptations to sprint interval training (SIT). Thirty-six recreationally active subjects, matched on key variables at baseline, completed a series of exercise tests before and following a 4-wk period in which they were allocated to one of the following groups: 1) SIT and NO3−-depleted beetroot juice as a placebo (SIT+PL); 2) SIT and NO3−-rich beetroot juice (~13 mmol NO3−/day; SIT+BR); or 3) no training and NO3−-rich beetroot juice (NT+BR). During moderate-intensity exercise, pulmonary oxygen uptake was reduced by 4% following 4 wk of SIT+BR and NT+BR (P < 0.05) but not SIT+PL. The peak work rate attained during incremental exercise increased more in SIT+BR than in SIT+PL (P < 0.05) or NT+BR (P < 0.001). The reduction in muscle and blood [lactate] and the increase in muscle pH from preintervention to postintervention were greater at 3 min of severe-intensity exercise in SIT+BR compared with SIT+PL and NT+BR (P < 0.05). However, the change in severe-intensity exercise performance was not different between SIT+BR and SIT+PL (P > 0.05). The relative proportion of type IIx muscle fibers in the vastus lateralis muscle was reduced in SIT+BR only (P < 0.05). These findings suggest that BR supplementation may enhance some aspects of the physiological adaptations to SIT. NEW & NOTEWORTHY We investigated the influence of nitrate-rich and nitrate-depleted beetroot juice on the muscle metabolic and physiological adaptations to 4 wk of sprint interval training. Compared with placebo, dietary nitrate supplementation reduced the O2 cost of submaximal exercise, resulted in greater improvement in incremental (but not severe-intensity) exercise performance, and augmented some muscle metabolic adaptations to training. Nitrate supplementation may facilitate some of the physiological responses to sprint interval training. PMID:27909231

  16. Biomechanical effects of sitting with adjustable ischial and lumbar support on occupational low back pain: evaluation of sitting load and back muscle activity

    PubMed Central

    Makhsous, Mohsen; Lin, Fang; Bankard, James; Hendrix, Ronald W; Hepler, Matthew; Press, Joel

    2009-01-01

    Background Compared to standing posture, sitting decreases lumbar lordosis, increases low back muscle activity, disc pressure, and pressure on the ischium, which are associated with occupational LBP. A sitting device that reduces spinal load and low back muscle activities may help increase sitting comfort and reduce LBP risk. The objective of this study is to investigate the biomechanical effect of sitting with a reduced ischial support and an enhanced lumbar support (Off-Loading) on load, interface pressure and muscle activities. Methods A laboratory test in low back pain (LBP) and asymptomatic subjects was designed to test the biomechanical effect of using the Off-Loading sitting posture. The load and interface pressure on seat and the backrest, and back muscle activities associated with usual and this Off-Loading posture were recorded and compared between the two postures. Results Compared with Normal (sitting upright with full support of the seat and flat backrest) posture, sitting in Off-Loading posture significantly shifted the center of the force and the peak pressure on the seat anteriorly towards the thighs. It also significantly decreased the contact area on the seat and increased that on the backrest. It decreased the lumbar muscle activities significantly. These effects are similar in individuals with and without LBP. Conclusion Sitting with reduced ischial support and enhanced lumbar support resulted in reduced sitting load on the lumbar spine and reduced the lumbar muscular activity, which may potentially reduce sitting-related LBP. PMID:19193245

  17. A 3D photographic capsule endoscope system with full field of view

    NASA Astrophysics Data System (ADS)

    Ou-Yang, Mang; Jeng, Wei-De; Lai, Chien-Cheng; Kung, Yi-Chinn; Tao, Kuan-Heng

    2013-09-01

    Current capsule endoscope uses one camera to capture the surface image in the intestine. It can only observe the abnormal point, but cannot know the exact information of this abnormal point. Using two cameras can generate 3D images, but the visual plane changes while capsule endoscope rotates. It causes that two cameras can't capture the images information completely. To solve this question, this research provides a new kind of capsule endoscope to capture 3D images, which is 'A 3D photographic capsule endoscope system'. The system uses three cameras to capture images in real time. The advantage is increasing the viewing range up to 2.99 times respect to the two camera system. The system can accompany 3D monitor provides the exact information of symptom points, helping doctors diagnose the disease.

  18. A Versatile Time-Lapse Camera System Developed by the Hawaiian Volcano Observatory for Use at Kilauea Volcano, Hawaii

    USGS Publications Warehouse

    Orr, Tim R.; Hoblitt, Richard P.

    2008-01-01

    Volcanoes can be difficult to study up close. Because it may be days, weeks, or even years between important events, direct observation is often impractical. In addition, volcanoes are often inaccessible due to their remote location and (or) harsh environmental conditions. An eruption adds another level of complexity to what already may be a difficult and dangerous situation. For these reasons, scientists at the U.S. Geological Survey (USGS) Hawaiian Volcano Observatory (HVO) have, for years, built camera systems to act as surrogate eyes. With the recent advances in digital-camera technology, these eyes are rapidly improving. One type of photographic monitoring involves the use of near-real-time network-enabled cameras installed at permanent sites (Hoblitt and others, in press). Time-lapse camera-systems, on the other hand, provide an inexpensive, easily transportable monitoring option that offers more versatility in site location. While time-lapse systems lack near-real-time capability, they provide higher image resolution and can be rapidly deployed in areas where the use of sophisticated telemetry required by the networked cameras systems is not practical. This report describes the latest generation (as of 2008) time-lapse camera system used by HVO for photograph acquisition in remote and hazardous sites on Kilauea Volcano.

  19. Empirical Study on Designing of Gaze Tracking Camera Based on the Information of User's Head Movement.

    PubMed

    Pan, Weiyuan; Jung, Dongwook; Yoon, Hyo Sik; Lee, Dong Eun; Naqvi, Rizwan Ali; Lee, Kwan Woo; Park, Kang Ryoung

    2016-08-31

    Gaze tracking is the technology that identifies a region in space that a user is looking at. Most previous non-wearable gaze tracking systems use a near-infrared (NIR) light camera with an NIR illuminator. Based on the kind of camera lens used, the viewing angle and depth-of-field (DOF) of a gaze tracking camera can be different, which affects the performance of the gaze tracking system. Nevertheless, to our best knowledge, most previous researches implemented gaze tracking cameras without ground truth information for determining the optimal viewing angle and DOF of the camera lens. Eye-tracker manufacturers might also use ground truth information, but they do not provide this in public. Therefore, researchers and developers of gaze tracking systems cannot refer to such information for implementing gaze tracking system. We address this problem providing an empirical study in which we design an optimal gaze tracking camera based on experimental measurements of the amount and velocity of user's head movements. Based on our results and analyses, researchers and developers might be able to more easily implement an optimal gaze tracking system. Experimental results show that our gaze tracking system shows high performance in terms of accuracy, user convenience and interest.

  20. Empirical Study on Designing of Gaze Tracking Camera Based on the Information of User’s Head Movement

    PubMed Central

    Pan, Weiyuan; Jung, Dongwook; Yoon, Hyo Sik; Lee, Dong Eun; Naqvi, Rizwan Ali; Lee, Kwan Woo; Park, Kang Ryoung

    2016-01-01

    Gaze tracking is the technology that identifies a region in space that a user is looking at. Most previous non-wearable gaze tracking systems use a near-infrared (NIR) light camera with an NIR illuminator. Based on the kind of camera lens used, the viewing angle and depth-of-field (DOF) of a gaze tracking camera can be different, which affects the performance of the gaze tracking system. Nevertheless, to our best knowledge, most previous researches implemented gaze tracking cameras without ground truth information for determining the optimal viewing angle and DOF of the camera lens. Eye-tracker manufacturers might also use ground truth information, but they do not provide this in public. Therefore, researchers and developers of gaze tracking systems cannot refer to such information for implementing gaze tracking system. We address this problem providing an empirical study in which we design an optimal gaze tracking camera based on experimental measurements of the amount and velocity of user’s head movements. Based on our results and analyses, researchers and developers might be able to more easily implement an optimal gaze tracking system. Experimental results show that our gaze tracking system shows high performance in terms of accuracy, user convenience and interest. PMID:27589768

  1. The Orbiter camera payload system's large-format camera and attitude reference system

    NASA Technical Reports Server (NTRS)

    Schardt, B. B.; Mollberg, B. H.

    1985-01-01

    The Orbiter camera payload system (OCPS) is an integrated photographic system carried into earth orbit as a payload in the Space Transportation System (STS) Orbiter vehicle's cargo bay. The major component of the OCPS is a large-format camera (LFC), a precision wide-angle cartographic instrument capable of producing high-resolution stereophotography of great geometric fidelity in multiple base-to-height ratios. A secondary and supporting system to the LFC is the attitude reference system (ARS), a dual-lens stellar camera array (SCA) and camera support structure. The SCA is a 70 mm film system that is rigidly mounted to the LFC lens support structure and, through the simultaneous acquisition of two star fields with each earth viewing LFC frame, makes it possible to precisely determine the pointing of the LFC optical axis with reference to the earth nadir point. Other components complete the current OCPS configuration as a high-precision cartographic data acquisition system. The primary design objective for the OCPS was to maximize system performance characteristics while maintaining a high level of reliability compatible with rocket launch conditions and the on-orbit environment. The full OCPS configuration was launched on a highly successful maiden voyage aboard the STS Orbiter vehicle Challenger on Oct. 5, 1984, as a major payload aboard the STS-41G mission.

  2. Nuclear medicine imaging system

    DOEpatents

    Bennett, Gerald W.; Brill, A. Bertrand; Bizais, Yves J.; Rowe, R. Wanda; Zubal, I. George

    1986-01-07

    A nuclear medicine imaging system having two large field of view scintillation cameras mounted on a rotatable gantry and being movable diametrically toward or away from each other is disclosed. In addition, each camera may be rotated about an axis perpendicular to the diameter of the gantry. The movement of the cameras allows the system to be used for a variety of studies, including positron annihilation, and conventional single photon emission, as well as static orthogonal dual multi-pinhole tomography. In orthogonal dual multi-pinhole tomography, each camera is fitted with a seven pinhole collimator to provide seven views from slightly different perspectives. By using two cameras at an angle to each other, improved sensitivity and depth resolution is achieved. The computer system and interface acquires and stores a broad range of information in list mode, including patient physiological data, energy data over the full range detected by the cameras, and the camera position. The list mode acquisition permits the study of attenuation as a result of Compton scatter, as well as studies involving the isolation and correlation of energy with a range of physiological conditions.

  3. Nuclear medicine imaging system

    DOEpatents

    Bennett, Gerald W.; Brill, A. Bertrand; Bizais, Yves J. C.; Rowe, R. Wanda; Zubal, I. George

    1986-01-01

    A nuclear medicine imaging system having two large field of view scintillation cameras mounted on a rotatable gantry and being movable diametrically toward or away from each other is disclosed. In addition, each camera may be rotated about an axis perpendicular to the diameter of the gantry. The movement of the cameras allows the system to be used for a variety of studies, including positron annihilation, and conventional single photon emission, as well as static orthogonal dual multi-pinhole tomography. In orthogonal dual multi-pinhole tomography, each camera is fitted with a seven pinhole collimator to provide seven views from slightly different perspectives. By using two cameras at an angle to each other, improved sensitivity and depth resolution is achieved. The computer system and interface acquires and stores a broad range of information in list mode, including patient physiological data, energy data over the full range detected by the cameras, and the camera position. The list mode acquisition permits the study of attenuation as a result of Compton scatter, as well as studies involving the isolation and correlation of energy with a range of physiological conditions.

  4. An improved camera trap for amphibians, reptiles, small mammals, and large invertebrates

    USGS Publications Warehouse

    Hobbs, Michael T.; Brehme, Cheryl S.

    2017-01-01

    Camera traps are valuable sampling tools commonly used to inventory and monitor wildlife communities but are challenged to reliably sample small animals. We introduce a novel active camera trap system enabling the reliable and efficient use of wildlife cameras for sampling small animals, particularly reptiles, amphibians, small mammals and large invertebrates. It surpasses the detection ability of commonly used passive infrared (PIR) cameras for this application and eliminates problems such as high rates of false triggers and high variability in detection rates among cameras and study locations. Our system, which employs a HALT trigger, is capable of coupling to digital PIR cameras and is designed for detecting small animals traversing small tunnels, narrow trails, small clearings and along walls or drift fencing.

  5. An improved camera trap for amphibians, reptiles, small mammals, and large invertebrates.

    PubMed

    Hobbs, Michael T; Brehme, Cheryl S

    2017-01-01

    Camera traps are valuable sampling tools commonly used to inventory and monitor wildlife communities but are challenged to reliably sample small animals. We introduce a novel active camera trap system enabling the reliable and efficient use of wildlife cameras for sampling small animals, particularly reptiles, amphibians, small mammals and large invertebrates. It surpasses the detection ability of commonly used passive infrared (PIR) cameras for this application and eliminates problems such as high rates of false triggers and high variability in detection rates among cameras and study locations. Our system, which employs a HALT trigger, is capable of coupling to digital PIR cameras and is designed for detecting small animals traversing small tunnels, narrow trails, small clearings and along walls or drift fencing.

  6. ARNICA, the Arcetri Near-Infrared Camera

    NASA Astrophysics Data System (ADS)

    Lisi, F.; Baffa, C.; Bilotti, V.; Bonaccini, D.; del Vecchio, C.; Gennari, S.; Hunt, L. K.; Marcucci, G.; Stanga, R.

    1996-04-01

    ARNICA (ARcetri Near-Infrared CAmera) is the imaging camera for the near-infrared bands between 1.0 and 2.5 microns that the Arcetri Observatory has designed and built for the Infrared Telescope TIRGO located at Gornergrat, Switzerland. We describe the mechanical and optical design of the camera, and report on the astronomical performance of ARNICA as measured during the commissioning runs at the TIRGO (December, 1992 to December 1993), and an observing run at the William Herschel Telescope, Canary Islands (December, 1993). System performance is defined in terms of efficiency of the camera+telescope system and camera sensitivity for extended and point-like sources. (SECTION: Astronomical Instrumentation)

  7. Video auto stitching in multicamera surveillance system

    NASA Astrophysics Data System (ADS)

    He, Bin; Zhao, Gang; Liu, Qifang; Li, Yangyang

    2012-01-01

    This paper concerns the problem of video stitching automatically in a multi-camera surveillance system. Previous approaches have used multiple calibrated cameras for video mosaic in large scale monitoring application. In this work, we formulate video stitching as a multi-image registration and blending problem, and not all cameras are needed to be calibrated except a few selected master cameras. SURF is used to find matched pairs of image key points from different cameras, and then camera pose is estimated and refined. Homography matrix is employed to calculate overlapping pixels and finally implement boundary resample algorithm to blend images. The result of simulation demonstrates the efficiency of our method.

  8. Video auto stitching in multicamera surveillance system

    NASA Astrophysics Data System (ADS)

    He, Bin; Zhao, Gang; Liu, Qifang; Li, Yangyang

    2011-12-01

    This paper concerns the problem of video stitching automatically in a multi-camera surveillance system. Previous approaches have used multiple calibrated cameras for video mosaic in large scale monitoring application. In this work, we formulate video stitching as a multi-image registration and blending problem, and not all cameras are needed to be calibrated except a few selected master cameras. SURF is used to find matched pairs of image key points from different cameras, and then camera pose is estimated and refined. Homography matrix is employed to calculate overlapping pixels and finally implement boundary resample algorithm to blend images. The result of simulation demonstrates the efficiency of our method.

  9. Detecting method of subjects' 3D positions and experimental advanced camera control system

    NASA Astrophysics Data System (ADS)

    Kato, Daiichiro; Abe, Kazuo; Ishikawa, Akio; Yamada, Mitsuho; Suzuki, Takahito; Kuwashima, Shigesumi

    1997-04-01

    Steady progress is being made in the development of an intelligent robot camera capable of automatically shooting pictures with a powerful sense of reality or tracking objects whose shooting requires advanced techniques. Currently, only experienced broadcasting cameramen can provide these pictures.TO develop an intelligent robot camera with these abilities, we need to clearly understand how a broadcasting cameraman assesses his shooting situation and how his camera is moved during shooting. We use a real- time analyzer to study a cameraman's work and his gaze movements at studios and during sports broadcasts. This time, we have developed a detecting method of subjects' 3D positions and an experimental camera control system to help us further understand the movements required for an intelligent robot camera. The features are as follows: (1) Two sensor cameras shoot a moving subject and detect colors, producing its 3D coordinates. (2) Capable of driving a camera based on camera movement data obtained by a real-time analyzer. 'Moving shoot' is the name we have given to the object position detection technology on which this system is based. We used it in a soccer game, producing computer graphics showing how players moved. These results will also be reported.

  10. View Northward from Spirit's Winter Roost

    NASA Technical Reports Server (NTRS)

    2006-01-01

    One part of the research program that NASA's Mars Exploration Rover Spirit is conducting while sitting at a favorable location for wintertime solar energy is the most detailed panorama yet taken on the surface of Mars. This view is a partial preliminary product from the continuing work on the full image, which will be called the 'McMurdo Panorama.'

    Spirit's panoramic camera (Pancam) began taking exposures for the McMurdo Panorama on the rover's 814th Martian day (April 18, 2006). The rover has accumulated more than 900 exposures for this panorama so far, through all of the Pancam mineralogy filters and using little or no image compression. Even with a tilt toward the winter sun, the amount of energy available daily is small, so the job will still take one to two more months to complete.

    This portion of the work in progress looks toward the north. 'Husband Hill,' which Spirit was climbing a year ago, is on the horizon near the center. 'Home Plate' is a between that hill and the rover's current position. Wheel tracks imprinted when Spirit drove south from Home Plate can be seen crossing the middle distance of the image from the center to the right.

    This is an approximate true-color rendering combining exposures taken through three of the panoramic camera's filters. The filters used are centered on wavelengths of 750 nanometers, 530 nanometers and 430 nanometers.

  11. Performance Characteristics For The Orbiter Camera Payload System's Large Format Camera (LFC)

    NASA Astrophysics Data System (ADS)

    MoIIberg, Bernard H.

    1981-11-01

    The Orbiter Camera Payload System, the OCPS, is an integrated photographic system which is carried into Earth orbit as a payload in the Shuttle Orbiter vehicle's cargo bay. The major component of the OCPS is a Large Format Camera (LFC) which is a precision wide-angle cartographic instrument that is capable of produc-ing high resolution stereophotography of great geometric fidelity in multiple base to height ratios. The primary design objective for the LFC was to maximize all system performance characteristics while maintaining a high level of reliability compatible with rocket launch conditions and the on-orbit environment.

  12. Eye gaze tracking for endoscopic camera positioning: an application of a hardware/software interface developed to automate Aesop.

    PubMed

    Ali, S M; Reisner, L A; King, B; Cao, A; Auner, G; Klein, M; Pandya, A K

    2008-01-01

    A redesigned motion control system for the medical robot Aesop allows automating and programming its movements. An IR eye tracking system has been integrated with this control interface to implement an intelligent, autonomous eye gaze-based laparoscopic positioning system. A laparoscopic camera held by Aesop can be moved based on the data from the eye tracking interface to keep the user's gaze point region at the center of a video feedback monitor. This system setup provides autonomous camera control that works around the surgeon, providing an optimal robotic camera platform.

  13. The Receptor-Like Kinase SIT1 Mediates Salt Sensitivity by Activating MAPK3/6 and Regulating Ethylene Homeostasis in Rice[C][W

    PubMed Central

    Li, Chen-Hui; Wang, Geng; Zhao, Ji-Long; Zhang, Li-Qing; Ai, Lian-Feng; Han, Yong-Feng; Sun, Da-Ye; Zhang, Sheng-Wei; Sun, Ying

    2014-01-01

    High salinity causes growth inhibition and shoot bleaching in plants that do not tolerate high salt (glycophytes), including most crops. The molecules affected directly by salt and linking the extracellular stimulus to intracellular responses remain largely unknown. Here, we demonstrate that rice (Oryza sativa) Salt Intolerance 1 (SIT1), a lectin receptor-like kinase expressed mainly in root epidermal cells, mediates salt sensitivity. NaCl rapidly activates SIT1, and in the presence of salt, as SIT1 kinase activity increased, plant survival decreased. Rice MPK3 and MPK6 function as the downstream effectors of SIT1. SIT1 phosphorylates MPK3 and 6, and their activation by salt requires SIT1. SIT1 mediates ethylene production and salt-induced ethylene signaling. SIT1 promotes accumulation of reactive oxygen species (ROS), leading to growth inhibition and plant death under salt stress, which occurred in an MPK3/6- and ethylene signaling-dependent manner in Arabidopsis thaliana. Our findings demonstrate the existence of a SIT1-MPK3/6 cascade that mediates salt sensitivity by affecting ROS and ethylene homeostasis and signaling. These results provide important information for engineering salt-tolerant crops. PMID:24907341

  14. Application of Machine Learning Approaches for Classifying Sitting Posture Based on Force and Acceleration Sensors.

    PubMed

    Zemp, Roland; Tanadini, Matteo; Plüss, Stefan; Schnüriger, Karin; Singh, Navrag B; Taylor, William R; Lorenzetti, Silvio

    2016-01-01

    Occupational musculoskeletal disorders, particularly chronic low back pain (LBP), are ubiquitous due to prolonged static sitting or nonergonomic sitting positions. Therefore, the aim of this study was to develop an instrumented chair with force and acceleration sensors to determine the accuracy of automatically identifying the user's sitting position by applying five different machine learning methods (Support Vector Machines, Multinomial Regression, Boosting, Neural Networks, and Random Forest). Forty-one subjects were requested to sit four times in seven different prescribed sitting positions (total 1148 samples). Sixteen force sensor values and the backrest angle were used as the explanatory variables (features) for the classification. The different classification methods were compared by means of a Leave-One-Out cross-validation approach. The best performance was achieved using the Random Forest classification algorithm, producing a mean classification accuracy of 90.9% for subjects with which the algorithm was not familiar. The classification accuracy varied between 81% and 98% for the seven different sitting positions. The present study showed the possibility of accurately classifying different sitting positions by means of the introduced instrumented office chair combined with machine learning analyses. The use of such novel approaches for the accurate assessment of chair usage could offer insights into the relationships between sitting position, sitting behaviour, and the occurrence of musculoskeletal disorders.

  15. Which population groups are most unaware of CVD risks associated with sitting time?

    PubMed

    Duncan, Mitch J; Gilson, Nicholas; Vandelanotte, Corneel

    2014-08-01

    Prolonged sitting is an emerging risk factor for poor health yet few studies have examined awareness of the risks associated with sitting behaviours. This study identifies the population subgroups with the highest levels of unawareness regarding the cardiovascular disease (CVD) risks associated with sitting behaviours. Adults (n=1256) living in Queensland, Australia completed a telephone-based survey in 2011, analysis conducted in 2013. The survey assessed participant's socio-demographic characteristics, physical activity, sitting behaviours and awareness of CVD risks associated with three sitting behaviours: 1) sitting for prolonged periods, 2), sitting for prolonged periods whilst also engaging in regular physical activity, and 3) breaking up periods of prolonged sitting with short activity breaks. Population sub-groups with the highest levels of unawareness were identified based on socio-demographic and behavioural characteristics using signal detection analysis. Unawareness ranged from 23.3% to 67.0%. Age was the most important variable in differentiating awareness levels; younger adults had higher levels of unawareness. Body mass index, physical activity, TV viewing, employment status and time spent at work also identified population sub-groups. Unawareness of CVD risk for prolonged sitting was moderately high overall. Younger adults had high levels of unawareness on all of the outcomes examined. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. Center of pressure and the projection of the time-course of sitting skill acquisition.

    PubMed

    Haworth, Joshua L; Harbourne, Regina T; Vallabhajosula, Srikant; Stergiou, Nicholas

    2013-09-01

    A normal time-course for the acquisition of sitting is essential. A delay in sitting may affect other developmental milestones, resulting in deficiencies in overall skill. Therefore, our aim was to identify variables whose measures at the very beginning of sitting would allow for the projection of the evolution of the sitting skill. Center of pressure data were collected from the postural sway of twenty-six typically developing infants while sitting on a force platform with a beginning ability to sit upright. Spatial, temporal and frequency variables of postural sway were obtained from both the medial/lateral and anterior/posterior directions of sway. Discriminant function analysis was conducted to identify potential predictors of the duration between onset and fully independent sitting. Gender (p=0.025), median frequency (p=0.006), and correlation dimension (p=0.002) were identified to be predictive of grouping with 73.1% correct classification of the participating infants into short, mid, and long delay groups. In conclusion, measures taken at the earliest stage of sitting may allow the projection of the time-course to achieve independent sitting for typical infants. This approach may be useful for monitoring typical development. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Pedestrian Detection Based on Adaptive Selection of Visible Light or Far-Infrared Light Camera Image by Fuzzy Inference System and Convolutional Neural Network-Based Verification.

    PubMed

    Kang, Jin Kyu; Hong, Hyung Gil; Park, Kang Ryoung

    2017-07-08

    A number of studies have been conducted to enhance the pedestrian detection accuracy of intelligent surveillance systems. However, detecting pedestrians under outdoor conditions is a challenging problem due to the varying lighting, shadows, and occlusions. In recent times, a growing number of studies have been performed on visible light camera-based pedestrian detection systems using a convolutional neural network (CNN) in order to make the pedestrian detection process more resilient to such conditions. However, visible light cameras still cannot detect pedestrians during nighttime, and are easily affected by shadows and lighting. There are many studies on CNN-based pedestrian detection through the use of far-infrared (FIR) light cameras (i.e., thermal cameras) to address such difficulties. However, when the solar radiation increases and the background temperature reaches the same level as the body temperature, it remains difficult for the FIR light camera to detect pedestrians due to the insignificant difference between the pedestrian and non-pedestrian features within the images. Researchers have been trying to solve this issue by inputting both the visible light and the FIR camera images into the CNN as the input. This, however, takes a longer time to process, and makes the system structure more complex as the CNN needs to process both camera images. This research adaptively selects a more appropriate candidate between two pedestrian images from visible light and FIR cameras based on a fuzzy inference system (FIS), and the selected candidate is verified with a CNN. Three types of databases were tested, taking into account various environmental factors using visible light and FIR cameras. The results showed that the proposed method performs better than the previously reported methods.

  18. Not All Is Lost: Old Adults Retain Flexibility in Motor Behaviour during Sit-to-Stand

    PubMed Central

    Greve, Christian; Zijlstra, Wiebren; Hortobágyi, Tibor; Bongers, Raoul M.

    2013-01-01

    Sit-to-stand is a fundamental activity of daily living, which becomes increasingly difficult with advancing age. Due to severe loss of leg strength old adults are required to change the way they rise from a chair and maintain stability. Here we examine whether old compared to young adults differently prioritize task-important performance variables and whether there are age-related differences in the use of available motor flexibility. We applied the uncontrolled manifold analysis to decompose trial-to-trial variability in joint kinematics into variability that stabilizes and destabilizes task-important performance variables. Comparing the amount of variability stabilizing and destabilizing task-important variables enabled us to identify the variable of primary importance for the task. We measured maximal isometric voluntary force of three muscle groups in the right leg. Independent of age and muscle strength, old and young adults similarly prioritized stability of the ground reaction force vector during sit-to-stand. Old compared to young adults employed greater motor flexibility, stabilizing ground reaction forces during sit-to-sand. We concluded that freeing those degrees of freedom that stabilize task-important variables is a strategy used by the aging neuromuscular system to compensate for strength deficits. PMID:24204952

  19. Application of infrared uncooled cameras in surveillance systems

    NASA Astrophysics Data System (ADS)

    Dulski, R.; Bareła, J.; Trzaskawka, P.; PiÄ tkowski, T.

    2013-10-01

    The recent necessity to protect military bases, convoys and patrols gave serious impact to the development of multisensor security systems for perimeter protection. One of the most important devices used in such systems are IR cameras. The paper discusses technical possibilities and limitations to use uncooled IR camera in a multi-sensor surveillance system for perimeter protection. Effective ranges of detection depend on the class of the sensor used and the observed scene itself. Application of IR camera increases the probability of intruder detection regardless of the time of day or weather conditions. It also simultaneously decreased the false alarm rate produced by the surveillance system. The role of IR cameras in the system was discussed as well as technical possibilities to detect human being. Comparison of commercially available IR cameras, capable to achieve desired ranges was done. The required spatial resolution for detection, recognition and identification was calculated. The simulation of detection ranges was done using a new model for predicting target acquisition performance which uses the Targeting Task Performance (TTP) metric. Like its predecessor, the Johnson criteria, the new model bounds the range performance with image quality. The scope of presented analysis is limited to the estimation of detection, recognition and identification ranges for typical thermal cameras with uncooled microbolometer focal plane arrays. This type of cameras is most widely used in security systems because of competitive price to performance ratio. Detection, recognition and identification range calculations were made, and the appropriate results for the devices with selected technical specifications were compared and discussed.

  20. Video model deformation system for the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Burner, A. W.; Snow, W. L.; Goad, W. K.

    1983-01-01

    A photogrammetric closed circuit television system to measure model deformation at the National Transonic Facility is described. The photogrammetric approach was chosen because of its inherent rapid data recording of the entire object field. Video cameras are used to acquire data instead of film cameras due to the inaccessibility of cameras which must be housed within the cryogenic, high pressure plenum of this facility. A rudimentary theory section is followed by a description of the video-based system and control measures required to protect cameras from the hostile environment. Preliminary results obtained with the same camera placement as planned for NTF are presented and plans for facility testing with a specially designed test wing are discussed.

  1. Evaluation of thermal cameras in quality systems according to ISO 9000 or EN 45000 standards

    NASA Astrophysics Data System (ADS)

    Chrzanowski, Krzysztof

    2001-03-01

    According to the international standards ISO 9001-9004 and EN 45001-45003 the industrial plants and the accreditation laboratories that implemented the quality systems according to these standards are required to evaluate an uncertainty of measurements. Manufacturers of thermal cameras do not offer any data that could enable estimation of measurement uncertainty of these imagers. Difficulties in determining the measurement uncertainty is an important limitation of thermal cameras for applications in the industrial plants and the cooperating accreditation laboratories that have implemented these quality systems. A set of parameters for characterization of commercial thermal cameras, a measuring set, some results of testing of these cameras, a mathematical model of uncertainty, and a software that enables quick calculation of uncertainty of temperature measurements with thermal cameras are presented in this paper.

  2. Can we reduce the effort of maintaining a neutral sitting posture? A pilot study.

    PubMed

    O'Sullivan, Kieran; McCarthy, Raymond; White, Alison; O'Sullivan, Leonard; Dankaerts, Wim

    2012-12-01

    Neutral sitting postures encouraging lumbar lordosis have been recommended in the management of sitting-related low back pain (LBP). However, prolonged lordotic sitting postures can be associated with increased fatigue and discomfort. This pilot study investigated whether changing the type of chair used in sitting can reduce the effort of maintaining a neutral sitting posture. The muscle activation of six trunk muscles was recorded using surface electromyography in 12 painfree participants. Participants were facilitated into a neutral sitting posture for 1 min on both a standard backless office chair and a dynamic, forward-inclined chair (Back App). Lumbar multifidus activity was significantly lower on the Back App chair (p=0.013). None of the other five trunk muscles measured demonstrated a significant difference in activity between the chairs. There was no significant difference (p=0.108) in the perceived effort of maintaining the neutral sitting posture on the two chairs. This study suggests that the lumbar multifidus activation required to maintain a neutral sitting posture can be reduced by considering the type of chair used. The mechanism through which the Back App chair reduces lumbar multifidus activation is unclear, but the greatest difference between chairs is the degree of hip flexion. The ability to maintain a neutral lumbar posture with less lumbar multifidus activation is potentially advantageous during prolonged sitting. Further investigations of the effects of chair design on longer duration sitting, and among LBP subjects, are warranted. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Capillary zone electrophoresis determination of aniline and pyridine in sewage samples using transient isotachophoresis with a system-induced terminator.

    PubMed

    Hattori, Takanari; Okamura, Hideo; Asaoka, Satoshi; Fukushi, Keiichi

    2017-08-18

    Transient isotachophoresis (tITP) with a system-induced terminator (SIT) was developed for capillary zone electrophoresis (CZE) determination of aniline (An + ) and pyridine (Py + ) in sewage samples. After sample injection, a water vial was set at the sample-inlet side. Then voltage was applied to generate a system-induced terminator (H + ). Experiments and simulations revealed a concentration effect by tITP with an SIT: background electrolyte (BGE) - 100mM acetic acid (AcOH) and 50mM NaOH (pH 4.6); detection wavelength - 200nm for An + and 254nm for Py + ; vacuum injection period - 15s (190nL); SIT generation - 10kV applied for 80s with the sample inlet side anode; separation voltage - 20kV with the sample inlet side anode. The limits of detection (LODs, S/N=3) of An + and Py + respectively reached 10 and 42μg/L, with good repeatability (peak area RSDs≤6.9%) and calibration graph linearity (R 2 =0.9997). The proposed method was applied for determination of An + and Py + in sewage samples. Recoveries of An + (0.50mg/L) and Py + (2.0mg/L) in spiked sewage samples were 94-104%. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. RAAAF's office landscape The End of Sitting: Energy expenditure and temporary comfort when working in non-sitting postures.

    PubMed

    Caljouw, Simone R; de Vries, Rutger; Withagen, Rob

    2017-01-01

    An earlier study suggested that the activity-inviting office landscape called "The End of Sitting", designed by Rietveld Architecture Art Affordances (RAAAF), should be considered as an alternative working environment to prevent sedentary behavior. The End of Sitting lacks chairs and tables but consists instead of a myriad of sloped surfaces at different heights that afford workers to stand, lean or recline at different locations. In this study, we assessed the impact of four of its workspaces on physical intensity, temporary comfort and productivity of office work and compared the outcomes with sitting and standing behind a desk. Twenty-four participants worked for 10 minutes in each of the six test conditions. Energy expenditure, measured by indirect calorimetry, and heart rate were recorded. Questionnaires were used to assess the perceived comfort. The number of words found in the word search test was counted as a measure of productivity. The majority of The End of Sitting workspaces led to a significant increase in energy expenditure compared with sitting behind a desk (ps < .05). Average MET values ranged from 1.40 to 1.58 which is a modest rise in energy expenditure compared to sitting (1.32 METs) and not significantly different from standing (1.47 METs). The scores on the general comfort scale indicated that some workspaces were less comfortable than sitting (ps < .05), but the vast majority of participants reported that at least one of The End of Sitting workspaces was equally or more comfortable than sitting. No differences in productivity between the test conditions were found. Further long-term studies are required to assess the behavioral adaptations, productivity and the level of comfort when using The End of Sitting as a permanent office.

  5. Reducing children's classroom sitting time using sit-to-stand desks: findings from pilot studies in UK and Australian primary schools.

    PubMed

    Clemes, Stacy A; Barber, Sally E; Bingham, Daniel D; Ridgers, Nicola D; Fletcher, Elly; Pearson, Natalie; Salmon, Jo; Dunstan, David W

    2016-09-01

    This research examined the influence of sit-to-stand desks on classroom sitting time in primary school children. Pilot controlled trials with similar intervention strategies were conducted in primary schools in Melbourne, Australia, and Bradford, UK. Sit-to-stand desks replaced all standard desks in the Australian intervention classroom. Six sit-to-stand desks replaced a bank of standard desks in the UK intervention classroom. Children were exposed to the sit-to-stand desks for 9-10 weeks. Control classrooms retained their normal seated desks. Classroom sitting time was measured at baseline and follow-up using the activPAL3 inclinometer. Thirty UK and 44 Australian children provided valid activPAL data at baseline and follow-up. The proportion of time spent sitting in class decreased significantly at follow-up in both intervention groups (UK: -9.8 ± 16.5% [-52.4 ± 66.6 min/day]; Australian: -9.4 ± 10% [-43.7 ± 29.9 min/day]). No significant changes in classroom sitting time were observed in the UK control group, while a significant reduction was observed in the Australian control group (-5.9 ± 11.7% [-28.2 ± 28.3 min/day]). Irrespective of implementation, incorporating sit-to-stand desks into classrooms appears to be an effective way of reducing classroom sitting in this diverse sample of children. Longer term efficacy trials are needed to determine effects on children's health and learning. © The Author 2015. Published by Oxford University Press on behalf of Faculty of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  6. Temporal patterns of sitting at work are associated with neck-shoulder pain in blue-collar workers: a cross-sectional analysis of accelerometer data in the DPHACTO study.

    PubMed

    Hallman, David M; Mathiassen, Svend Erik; Heiden, Marina; Gupta, Nidhi; Jørgensen, Marie Birk; Holtermann, Andreas

    2016-07-01

    Our aim was to examine the extent to which temporal patterns of sitting during occupational work and during leisure-time, assessed using accelerometry, are associated with intense neck-shoulder pain (NSP) in blue-collar workers. The population consisted of 659 Danish blue-collar workers. Accelerometers were attached to the thigh, hip, trunk and upper dominant arm to measure sitting time and physical activity across four consecutive days. Temporal sitting patterns were expressed separately for work and leisure by the proportion of total time spent sitting in brief bursts (0-5 min), moderate (>5-20 min) and prolonged (>20 min) periods. The peak NSP intensity during the previous 3 months was assessed using a numerical rating scale (range 0-10) and dichotomized into a lower (≤4) and higher (>4) NSP score. Logistic regression analyses with multiple adjustments for individual and occupational factors were performed to determine the association between brief, moderate and prolonged sitting periods, and NSP intensity. Time in brief bursts of occupational sitting was negatively associated with NSP intensity (adjusted OR 0.68, 95 % CI 0.48-0.98), while time in moderate periods of occupational sitting showed a positive association with NSP (adjusted OR 1.32, 95 % CI 1.04-1.69). Time in prolonged periods of occupational sitting was not associated with NSP (adjusted OR 0.78, 95 % CI 0.78-1.09). We found no significant association between brief, moderate or prolonged sitting periods during leisure, and NSP. Our findings indicate that the association between occupational sitting time and intense NSP among blue-collar workers is sensitive to the temporal pattern of sitting.

  7. Effect of low back pain on the kinematics and joint coordination of the lumbar spine and hip during sit-to-stand and stand-to-sit.

    PubMed

    Shum, Gary L K; Crosbie, Jack; Lee, Raymond Y W

    2005-09-01

    Experimental study to describe lumbar spine and hip joint movements during sit-to-stand and stand-to-sit. To examine differences in the kinematics and joint coordination of the lumbar spine and hips during sit-to-stand and stand-to-sit between healthy subjects and patients with subacute low back pain (LBP). There is a paucity of information on the coordination of movements of lumbar spine and hips during sit-to-stand and stand-to-sit. The effect of LBP, with or without nerve root signs, is largely unknown. A three-dimensional real-time electromagnetic tracking device was used to measure movements of the lumbar spine and hips during sit-to-stand and stand-to-sit. Sixty subacute LBP participants with or without straight leg raise signs and 20 healthy asymptomatic participants were recruited. The kinematic patterns of lumbar spine and hips were analyzed. Coordination between the two joints was studied by relative phase angle analysis. The mobility of the spine and hips was significantly limited in back pain subjects. It was observed that LBP subjects employed various strategies to compensate for the limited motions at the hips and lumbar spine. The contribution of the lumbar spine relative to that of the hip was found to be reduced for subjects with LBP. The lumbar spine-hip joint coordination was significantly altered in back pain subjects, in particular, those with positive straight leg raise sign. Back pain was related to changes in the kinematics and coordination of the lumbar spine and hips during sit-to-stand and stand-to-sit. Assessment of back pain patients should include kinematic analysis of the hips as well as the spine.

  8. Impact of an 8-Month Trial Using Height-Adjustable Desks on Children’s Classroom Sitting Patterns and Markers of Cardio-Metabolic and Musculoskeletal Health

    PubMed Central

    Contardo Ayala, Ana María; Salmon, Jo; Timperio, Anna; Sudholz, Bronwyn; Ridgers, Nicola D.; Sethi, Parneet; Dunstan, David W.

    2016-01-01

    During school hours, children can sit for prolonged and unbroken periods of time. This study investigated the impact of an 8-month classroom-based intervention focusing on reducing and breaking-up sitting time on children’s cardio-metabolic risk factors (i.e., body mass index, waist circumference, blood pressure) and perceptions of musculoskeletal discomfort. Two Year-6 classes (24 students per class) in one primary school were assigned to either an intervention or control classroom. The intervention classroom was equipped with height-adjustable desks and the teacher was instructed in the delivery of pedagogical strategies to reduce and break-up sitting in class. The control classroom followed standard practice using traditional furniture. At baseline, and after 8-months, time spent sitting, standing, stepping, and sitting-bouts (occasions of continuous sitting) as well as the frequency of sit-to-stand transitions were obtained from activPAL inclinometers and the time spent in light-intensity physical activity was obtained from ActiGraph accelerometers. Demographics and musculoskeletal characteristics were obtained from a self-report survey. Hierarchical linear mixed models found that during class-time, children’s overall time spent sitting in long bouts (>10 min) were lower and the number of sit-to-stand transitions were higher in the intervention group compared to the control group, while no changes were observed for musculoskeletal pain/discomfort. No significant intervention effects were found for the anthropometrics measures and blood pressure. Height-adjustable desks and pedagogical strategies to reduce/break-up sitting can positively modify classroom sitting patterns in children. Longer interventions, larger and varied sample size may be needed to show health impacts; however, these desks did not increase musculoskeletal pain/discomfort. PMID:27973414

  9. Small Steps: Preliminary effectiveness and feasibility of an incremental goal-setting intervention to reduce sitting time in older adults.

    PubMed

    Lewis, L K; Rowlands, A V; Gardiner, P A; Standage, M; English, C; Olds, T

    2016-03-01

    This study aimed to evaluate the preliminary effectiveness and feasibility of a theory-informed program to reduce sitting time in older adults. Pre-experimental (pre-post) study. Thirty non-working adult (≥ 60 years) participants attended a one hour face-to-face intervention session and were guided through: a review of their sitting time; normative feedback on sitting time; and setting goals to reduce total sitting time and bouts of prolonged sitting. Participants chose six goals and integrated one per week incrementally for six weeks. Participants received weekly phone calls. Sitting time and bouts of prolonged sitting (≥ 30 min) were measured objectively for seven days (activPAL3c inclinometer) pre- and post-intervention. During these periods, a 24-h time recall instrument was administered by computer-assisted telephone interview. Participants completed a post-intervention project evaluation questionnaire. Paired t tests with sequential Bonferroni corrections and Cohen's d effect sizes were calculated for all outcomes. Twenty-seven participants completed the assessments (71.7 ± 6.5 years). Post-intervention, objectively-measured total sitting time was significantly reduced by 51.5 min per day (p=0.006; d=-0.58) and number of bouts of prolonged sitting by 0.8 per day (p=0.002; d=-0.70). Objectively-measured standing increased by 39 min per day (p=0.006; d=0.58). Participants self-reported spending 96 min less per day sitting (p<0.001; d=-0.77) and 32 min less per day watching television (p=0.005; d=-0.59). Participants were highly satisfied with the program. The 'Small Steps' program is a feasible and promising avenue for behavioral modification to reduce sitting time in older adults. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Self-Reported Sitting Time in New York City Adults, The Physical Activity and Transit Survey, 2010–2011

    PubMed Central

    Bartley, Katherine F.; Firestone, Melanie J.; Lee, Karen K.; Eisenhower, Donna L.

    2015-01-01

    Introduction Recent studies have demonstrated the negative health consequences associated with extended sitting time, including metabolic disturbances and decreased life expectancy. The objectives of this study were to characterize sitting time in an urban adult population and assess the validity of a 2-question method of self-reported sitting time. Methods The New York City Health Department conducted the 2010–2011 Physical Activity and Transit Survey (N = 3,597); a subset of participants wore accelerometers for 1 week (n = 667). Self-reported sitting time was assessed from 2 questions on time spent sitting (daytime and evening hours). Sedentary time was defined as accelerometer minutes with less than 100 counts on valid days. Descriptive statistics were used to estimate the prevalence of sitting time by demographic characteristics. Validity of sitting time with accelerometer-measured sedentary time was assessed using Spearman’s correlation and Bland-Altman techniques. All data were weighted to be representative of the New York City adult population based on the 2006–2008 American Community Survey. Results Mean daily self-reported sitting time was 423 minutes; mean accelerometer-measured sedentary time was 490 minutes per day (r = 0.32, P < .001). The mean difference was 49 minutes per day (limits of agreement: −441 to 343). Sitting time was higher in respondents at lower poverty and higher education levels and lower in Hispanics and people who were foreign-born. Conclusion Participants of higher socioeconomic status, who are not typically the focus of health disparities–related research, had the highest sitting times; Hispanics had the lowest levels. Sitting time may be accurately assessed by self-report with the 2-question method for population surveillance but may be limited in accurately characterizing individual-level behavior. PMID:26020549

  11. Self-reported sitting time in New York City adults, the Physical Activity and Transit Survey, 2010-2011.

    PubMed

    Yi, Stella S; Bartley, Katherine F; Firestone, Melanie J; Lee, Karen K; Eisenhower, Donna L

    2015-05-28

    Recent studies have demonstrated the negative health consequences associated with extended sitting time, including metabolic disturbances and decreased life expectancy. The objectives of this study were to characterize sitting time in an urban adult population and assess the validity of a 2-question method of self-reported sitting time. The New York City Health Department conducted the 2010-2011 Physical Activity and Transit Survey (N = 3,597); a subset of participants wore accelerometers for 1 week (n = 667). Self-reported sitting time was assessed from 2 questions on time spent sitting (daytime and evening hours). Sedentary time was defined as accelerometer minutes with less than 100 counts on valid days. Descriptive statistics were used to estimate the prevalence of sitting time by demographic characteristics. Validity of sitting time with accelerometer-measured sedentary time was assessed using Spearman's correlation and Bland-Altman techniques. All data were weighted to be representative of the New York City adult population based on the 2006-2008 American Community Survey. Mean daily self-reported sitting time was 423 minutes; mean accelerometer-measured sedentary time was 490 minutes per day (r = 0.32, P < .001). The mean difference was 49 minutes per day (limits of agreement: -441 to 343). Sitting time was higher in respondents at lower poverty and higher education levels and lower in Hispanics and people who were foreign-born. Participants of higher socioeconomic status, who are not typically the focus of health disparities-related research, had the highest sitting times; Hispanics had the lowest levels. Sitting time may be accurately assessed by self-report with the 2-question method for population surveillance but may be limited in accurately characterizing individual-level behavior.

  12. High-performance dual-speed CCD camera system for scientific imaging

    NASA Astrophysics Data System (ADS)

    Simpson, Raymond W.

    1996-03-01

    Traditionally, scientific camera systems were partitioned with a `camera head' containing the CCD and its support circuitry and a camera controller, which provided analog to digital conversion, timing, control, computer interfacing, and power. A new, unitized high performance scientific CCD camera with dual speed readout at 1 X 106 or 5 X 106 pixels per second, 12 bit digital gray scale, high performance thermoelectric cooling, and built in composite video output is described. This camera provides all digital, analog, and cooling functions in a single compact unit. The new system incorporates the A/C converter, timing, control and computer interfacing in the camera, with the power supply remaining a separate remote unit. A 100 Mbyte/second serial link transfers data over copper or fiber media to a variety of host computers, including Sun, SGI, SCSI, PCI, EISA, and Apple Macintosh. Having all the digital and analog functions in the camera made it possible to modify this system for the Woods Hole Oceanographic Institution for use on a remote controlled submersible vehicle. The oceanographic version achieves 16 bit dynamic range at 1.5 X 105 pixels/second, can be operated at depths of 3 kilometers, and transfers data to the surface via a real time fiber optic link.

  13. Wavelet based approach for posture transition estimation using a waist worn accelerometer.

    PubMed

    Bidargaddi, Niranjan; Klingbeil, Lasse; Sarela, Antti; Boyle, Justin; Cheung, Vivian; Yelland, Catherine; Karunanithi, Mohanraj; Gray, Len

    2007-01-01

    The ability to rise from a chair is considered to be important to achieve functional independence and quality of life. This sit-to-stand task is also a good indicator to assess condition of patients with chronic diseases. We developed a wavelet based algorithm for detecting and calculating the durations of sit-to-stand and stand-to-sit transitions from the signal vector magnitude of the measured acceleration signal. The algorithm was tested on waist worn accelerometer data collected from young subjects as well as geriatric patients. The test demonstrates that both transitions can be detected by using wavelet transformation applied to signal magnitude vector. Wavelet analysis produces an estimate of the transition pattern that can be used to calculate the transition duration that further gives clinically significant information on the patients condition. The method can be applied in a real life ambulatory monitoring system for assessing the condition of a patient living at home.

  14. Therapeutic effects of a horse riding simulator in children with cerebral palsy.

    PubMed

    Silva e Borges, Maria Beatriz; Werneck, Maria José da Silva; da Silva, Maria de Lourdes; Gandolfi, Lenora; Pratesi, Riccardo

    2011-10-01

    To evaluate the efficacy of horse ridding simulator on the sitting postural control of children with spastic diplegia. Forty children were randomly divided in a group using the simulator (RS) and a group performing conventional physical therapy (CT). FScan/Fmat equipment was used to register maximal displacement in antero-posterior (AP) and medio-lateral (ML) directions with children in sitting position. At the pre and post intervention stage both groups were classified according to the Gross Motor Function Classification System (GMFCS) and, after intervention, by the AUQEI questionnaire (Autoquestionnaire Qualité de vie Enfant Image). Comparison between groups disclosed statistically significant pos-intervention improvement both in the AP (p<0.0001) as in the ML (p<0.0069) direction in the RS group. The horse ridding simulator produced significant improvement in the postural control of children in sitting position, additionally showing a higher motor functionality and a better acceptance of the therapeutic intervention.

  15. An interactive web-based system using cloud for large-scale visual analytics

    NASA Astrophysics Data System (ADS)

    Kaseb, Ahmed S.; Berry, Everett; Rozolis, Erik; McNulty, Kyle; Bontrager, Seth; Koh, Youngsol; Lu, Yung-Hsiang; Delp, Edward J.

    2015-03-01

    Network cameras have been growing rapidly in recent years. Thousands of public network cameras provide tremendous amount of visual information about the environment. There is a need to analyze this valuable information for a better understanding of the world around us. This paper presents an interactive web-based system that enables users to execute image analysis and computer vision techniques on a large scale to analyze the data from more than 65,000 worldwide cameras. This paper focuses on how to use both the system's website and Application Programming Interface (API). Given a computer program that analyzes a single frame, the user needs to make only slight changes to the existing program and choose the cameras to analyze. The system handles the heterogeneity of the geographically distributed cameras, e.g. different brands, resolutions. The system allocates and manages Amazon EC2 and Windows Azure cloud resources to meet the analysis requirements.

  16. LSST camera control system

    NASA Astrophysics Data System (ADS)

    Marshall, Stuart; Thaler, Jon; Schalk, Terry; Huffer, Michael

    2006-06-01

    The LSST Camera Control System (CCS) will manage the activities of the various camera subsystems and coordinate those activities with the LSST Observatory Control System (OCS). The CCS comprises a set of modules (nominally implemented in software) which are each responsible for managing one camera subsystem. Generally, a control module will be a long lived "server" process running on an embedded computer in the subsystem. Multiple control modules may run on a single computer or a module may be implemented in "firmware" on a subsystem. In any case control modules must exchange messages and status data with a master control module (MCM). The main features of this approach are: (1) control is distributed to the local subsystem level; (2) the systems follow a "Master/Slave" strategy; (3) coordination will be achieved by the exchange of messages through the interfaces between the CCS and its subsystems. The interface between the camera data acquisition system and its downstream clients is also presented.

  17. Quantification of lower extremity physical exposures in various combinations of sit/stand time duration associated with sit-stand workstation.

    PubMed

    Pei, Huining; Yu, Suihuai; Babski-Reeves, Kari; Chu, Jianjie; Qu, Min; Tian, Baozhen; Li, Wenhua

    2017-05-16

    Sit-stand workstations are available for office work purposes but there is a dearth of quantitative evidence to state benefits for lower limb outcomes while using them. And there are no guidelines on what constitutes appropriate sit/stand time duration. The primary aim of this study has been to compare muscle activity and perceived discomfort in the lower extremity during various combinations of sit/stand time duration associated with a sit-stand workstation separately and to evaluate the effects of the sit-stand workstation on the lower extremity during the text entry task. During the 5 days, all participants completed a 2-h text entry task each day for various sit/stand time duration combinations as follows: 5/25 min, 10/20 min, 15/15 min, 20/10 min, 25/5 min. Lower extremity muscular exposure of 12 male and 13 female participants was collected at 8 sites by surface electromyography and body discomfort was calculated by a questionnaire under those 5 conditions. Results have demonstrated that lower extremity muscle activity has been significantly varied among the 5 sit/stand time duration groups. Perceived level of discomfort (PLD) has not differed significantly for 9 out of 10 body parts. The muscle activity of the thigh region was influenced by sit/stand time duration significantly. Ergonomic exposures of lower extremity when using a sit-stand workstation were increased, particularly during the long time standing posture. Results indicate that body mass index (BMI) and gender were not significant factors in this study. Combination of sit/stand time duration 25/5 min appears to show positive effects on relief of muscle exposure of back of thigh in the shifts of sitting and standing work position. Med Pr 2017;68(3):315-327. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  18. "Thinking on your feet": A qualitative evaluation of sit-stand desks in an Australian workplace.

    PubMed

    Grunseit, Anne Carolyn; Chau, Josephine Yuk-Yin; van der Ploeg, Hidde Pieter; Bauman, Adrian

    2013-04-18

    Epidemiological research has established sitting as a new risk factor for the development of non-communicable chronic disease. Sit-stand desks have been proposed as one strategy to reduce occupational sedentary time. This formative research study evaluated the acceptability and usability of manually and electrically operated sit-stand desks in a medium-sized government organisation located in Sydney, Australia. Sitting time pre- and three months post -installation of the sit-stand desks was measured using validated self-report measures. Additionally, three group interviews and one key-informant interview were conducted with staff regarding perceptions about ease of, and barriers to, use and satisfaction with the sit-stand desks. All interviews were recorded, transcribed and analysed for themes regarding usability and acceptability. Of 31 staff, 18 completed baseline questionnaires, and 13 completed follow-up questionnaires. The median proportion of sitting time for work was 85% (range 50%-95%) at baseline and 60% (range 10%-95%) at follow-up. Formal statistical testing of paired data (n=11) showed that the change from baseline to follow-up in time spent sitting (mean change=1.7 hours, p=.014) was statistically significant. From the qualitative data, reasons given for initiating use of the desks in the standing position were the potential health benefits, or a willingness to experiment or through external prompting. Factors influencing continued use included: concern for, and experience of, short and long term health impacts; perceived productivity whilst sitting and standing; practical accommodation of transitions between sitting and standing; electric or manual operation height adjustment. Several trajectories in patterns of initiation and continued use were identified that centered on the source and timing of commitment to using the desk in the standing position. Sit-stand desks had high usability and acceptability and reduced sitting time at work. Use could be promoted by emphasizing the health benefits, providing guidance on appropriate set-up and normalizing standing for work-related tasks.

  19. Effect of Sitting Pause Times on Balance After Supine to Standing Transfer in Dim Light.

    PubMed

    Johnson, Eric G; Albalwi, Abdulaziz A; Al-Dabbak, Fuad M; Daher, Noha S

    2017-06-01

    The risk of falling for older adults increases in dimly lit environments. Longer sitting pause times, before getting out of bed and standing during the night, may improve postural stability. The purpose of this study was to measure the effect of sitting pause times on postural sway velocity immediately after a supine to standing transfer in a dimly lit room in older adult women. Eighteen healthy women aged 65 to 75 years who were able to independently perform supine to standing transfers participated in the study. On each of 2 consecutive days, participants assumed the supine position on a mat table and closed their eyes for 45 minutes. Then, participants were instructed to open their eyes and transfer from supine to sitting, with either 2- or 30-second pause in the sitting position followed by standing. The sitting pause time order was randomized. A significant difference was observed in postural sway velocity between the 2- and 30-second sitting pause times. The results revealed that there was less postural sway velocity after 30-second than 2-second sitting pause time (0.61 ± 0.19 vs 1.22 ± 0.68, P < .001). Falls related to bathroom usage at night are the most common reported falls among older adults. In the present study, the investigators studied the effect of sitting pause times on postural sway velocity after changing position from supine to standing in a dimly lit environment. The findings showed that the mean postural sway velocity was significantly less after 30-second sitting pause time compared with 2-second sitting pause time. Postural sway velocity decreased when participants performed a sitting pause of 30 seconds before standing in a dimly lit environment. These results suggest that longer sitting pause times may improve adaptability to dimly lit environments, contributing to improved postural stability and reduced risk of fall in older adult women when getting out of bed at night.

  20. Physical Activity, Study Sitting Time, Leisure Sitting Time, and Sleep Time Are Differently Associated With Obesity in Korean Adolescents: A Population-Based Study.

    PubMed

    Kong, Il Gyu; Lee, Hyo-Jeong; Kim, So Young; Sim, Songyong; Choi, Hyo Geun

    2015-11-01

    Low physical activity, long leisure sitting time, and short sleep time are risk factors for obesity, but the association with study sitting time is unknown. The objective of this study was to evaluate the association between these factors and obesity.We analyzed the association between physical activity, study sitting time, leisure sitting time, and sleep time and subject weight (underweight, healthy weight, overweight, and obese), using data from a large population-based survey, the 2013 Korea Youth Risk Behavior Web-based Survey. Data from 53,769 participants were analyzed using multinomial logistic regression analyses with complex sampling. Age, sex, region of residence, economic level, smoking, stress level, physical activity, sitting time for study, sitting time for leisure, and sleep time were adjusted as the confounders.Low physical activity (adjusted odds ratios [AORs] = 1.03, 1.12) and long leisure sitting time (AORs = 1.15, 1.32) were positively associated with overweight and obese. Low physical activity (AOR = 1.33) and long leisure sitting time (AOR = 1.12) were also associated with underweight. Study sitting time was negatively associated with underweight (AOR = 0.86) but was unrelated to overweight (AOR = 0.97, 95% confidence interval [CI] = 0.91-1.03) and obese (AOR = 0.94, 95% CI = 0.84-1.04). Sleep time (<6 hours; ≥6 hours, <7 hours; ≥7 hours, <8 hours) was adversely associated with underweight (AORs = 0.67, 0.79, and 0.88) but positively associated with overweight (AORs = 1.19, 1.17, and 1.08) and obese (AORs = 1.33, 1.36, and 1.30) in a dose-response relationship.In adolescents, increasing physical activity, decreasing leisure sitting time, and obtaining sufficient sleep would be beneficial in maintaining a healthy weight. However, study sitting time was not associated with overweight or obese.

  1. “Thinking on your feet”: A qualitative evaluation of sit-stand desks in an Australian workplace

    PubMed Central

    2013-01-01

    Background Epidemiological research has established sitting as a new risk factor for the development of non-communicable chronic disease. Sit-stand desks have been proposed as one strategy to reduce occupational sedentary time. This formative research study evaluated the acceptability and usability of manually and electrically operated sit-stand desks in a medium-sized government organisation located in Sydney, Australia. Methods Sitting time pre- and three months post -installation of the sit-stand desks was measured using validated self-report measures. Additionally, three group interviews and one key-informant interview were conducted with staff regarding perceptions about ease of, and barriers to, use and satisfaction with the sit-stand desks. All interviews were recorded, transcribed and analysed for themes regarding usability and acceptability. Results Of 31 staff, 18 completed baseline questionnaires, and 13 completed follow-up questionnaires. The median proportion of sitting time for work was 85% (range 50%-95%) at baseline and 60% (range 10%-95%) at follow-up. Formal statistical testing of paired data (n=11) showed that the change from baseline to follow-up in time spent sitting (mean change=1.7 hours, p=.014) was statistically significant. From the qualitative data, reasons given for initiating use of the desks in the standing position were the potential health benefits, or a willingness to experiment or through external prompting. Factors influencing continued use included: concern for, and experience of, short and long term health impacts; perceived productivity whilst sitting and standing; practical accommodation of transitions between sitting and standing; electric or manual operation height adjustment. Several trajectories in patterns of initiation and continued use were identified that centered on the source and timing of commitment to using the desk in the standing position. Conclusions Sit-stand desks had high usability and acceptability and reduced sitting time at work. Use could be promoted by emphasizing the health benefits, providing guidance on appropriate set-up and normalizing standing for work-related tasks. PMID:23597291

  2. A system for extracting 3-dimensional measurements from a stereo pair of TV cameras

    NASA Technical Reports Server (NTRS)

    Yakimovsky, Y.; Cunningham, R.

    1976-01-01

    Obtaining accurate three-dimensional (3-D) measurement from a stereo pair of TV cameras is a task requiring camera modeling, calibration, and the matching of the two images of a real 3-D point on the two TV pictures. A system which models and calibrates the cameras and pairs the two images of a real-world point in the two pictures, either manually or automatically, was implemented. This system is operating and provides three-dimensional measurements resolution of + or - mm at distances of about 2 m.

  3. A compact high-definition low-cost digital stereoscopic video camera for rapid robotic surgery development.

    PubMed

    Carlson, Jay; Kowalczuk, Jędrzej; Psota, Eric; Pérez, Lance C

    2012-01-01

    Robotic surgical platforms require vision feedback systems, which often consist of low-resolution, expensive, single-imager analog cameras. These systems are retooled for 3D display by simply doubling the cameras and outboard control units. Here, a fully-integrated digital stereoscopic video camera employing high-definition sensors and a class-compliant USB video interface is presented. This system can be used with low-cost PC hardware and consumer-level 3D displays for tele-medical surgical applications including military medical support, disaster relief, and space exploration.

  4. Applications of a shadow camera system for energy meteorology

    NASA Astrophysics Data System (ADS)

    Kuhn, Pascal; Wilbert, Stefan; Prahl, Christoph; Garsche, Dominik; Schüler, David; Haase, Thomas; Ramirez, Lourdes; Zarzalejo, Luis; Meyer, Angela; Blanc, Philippe; Pitz-Paal, Robert

    2018-02-01

    Downward-facing shadow cameras might play a major role in future energy meteorology. Shadow cameras directly image shadows on the ground from an elevated position. They are used to validate other systems (e.g. all-sky imager based nowcasting systems, cloud speed sensors or satellite forecasts) and can potentially provide short term forecasts for solar power plants. Such forecasts are needed for electricity grids with high penetrations of renewable energy and can help to optimize plant operations. In this publication, two key applications of shadow cameras are briefly presented.

  5. Nonholonomic camera-space manipulation using cameras mounted on a mobile base

    NASA Astrophysics Data System (ADS)

    Goodwine, Bill; Seelinger, Michael J.; Skaar, Steven B.; Ma, Qun

    1998-10-01

    The body of work called `Camera Space Manipulation' is an effective and proven method of robotic control. Essentially, this technique identifies and refines the input-output relationship of the plant using estimation methods and drives the plant open-loop to its target state. 3D `success' of the desired motion, i.e., the end effector of the manipulator engages a target at a particular location with a particular orientation, is guaranteed when there is camera space success in two cameras which are adequately separated. Very accurate, sub-pixel positioning of a robotic end effector is possible using this method. To date, however, most efforts in this area have primarily considered holonomic systems. This work addresses the problem of nonholonomic camera space manipulation by considering the problem of a nonholonomic robot with two cameras and a holonomic manipulator on board the nonholonomic platform. While perhaps not as common in robotics, such a combination of holonomic and nonholonomic degrees of freedom are ubiquitous in industry: fork lifts and earth moving equipment are common examples of a nonholonomic system with an on-board holonomic actuator. The nonholonomic nature of the system makes the automation problem more difficult due to a variety of reasons; in particular, the target location is not fixed in the image planes, as it is for holonomic systems (since the cameras are attached to a moving platform), and there is a fundamental `path dependent' nature of nonholonomic kinematics. This work focuses on the sensor space or camera-space-based control laws necessary for effectively implementing an autonomous system of this type.

  6. Backing collisions: a study of drivers' eye and backing behaviour using combined rear-view camera and sensor systems.

    PubMed

    Hurwitz, David S; Pradhan, Anuj; Fisher, Donald L; Knodler, Michael A; Muttart, Jeffrey W; Menon, Rajiv; Meissner, Uwe

    2010-04-01

    Backing crash injures can be severe; approximately 200 of the 2,500 reported injuries of this type per year to children under the age of 15 years result in death. Technology for assisting drivers when backing has limited success in preventing backing crashes. Two questions are addressed: Why is the reduction in backing crashes moderate when rear-view cameras are deployed? Could rear-view cameras augment sensor systems? 46 drivers (36 experimental, 10 control) completed 16 parking trials over 2 days (eight trials per day). Experimental participants were provided with a sensor camera system, controls were not. Three crash scenarios were introduced. Parking facility at UMass Amherst, USA. 46 drivers (33 men, 13 women) average age 29 years, who were Massachusetts residents licensed within the USA for an average of 9.3 years. Interventions Vehicles equipped with a rear-view camera and sensor system-based parking aid. Subject's eye fixations while driving and researcher's observation of collision with objects during backing. Only 20% of drivers looked at the rear-view camera before backing, and 88% of those did not crash. Of those who did not look at the rear-view camera before backing, 46% looked after the sensor warned the driver. This study indicates that drivers not only attend to an audible warning, but will look at a rear-view camera if available. Evidence suggests that when used appropriately, rear-view cameras can mitigate the occurrence of backing crashes, particularly when paired with an appropriate sensor system.

  7. Backing collisions: a study of drivers’ eye and backing behaviour using combined rear-view camera and sensor systems

    PubMed Central

    Hurwitz, David S; Pradhan, Anuj; Fisher, Donald L; Knodler, Michael A; Muttart, Jeffrey W; Menon, Rajiv; Meissner, Uwe

    2012-01-01

    Context Backing crash injures can be severe; approximately 200 of the 2,500 reported injuries of this type per year to children under the age of 15 years result in death. Technology for assisting drivers when backing has limited success in preventing backing crashes. Objectives Two questions are addressed: Why is the reduction in backing crashes moderate when rear-view cameras are deployed? Could rear-view cameras augment sensor systems? Design 46 drivers (36 experimental, 10 control) completed 16 parking trials over 2 days (eight trials per day). Experimental participants were provided with a sensor camera system, controls were not. Three crash scenarios were introduced. Setting Parking facility at UMass Amherst, USA. Subjects 46 drivers (33 men, 13 women) average age 29 years, who were Massachusetts residents licensed within the USA for an average of 9.3 years. Interventions Vehicles equipped with a rear-view camera and sensor system-based parking aid. Main Outcome Measures Subject’s eye fixations while driving and researcher’s observation of collision with objects during backing. Results Only 20% of drivers looked at the rear-view camera before backing, and 88% of those did not crash. Of those who did not look at the rear-view camera before backing, 46% looked after the sensor warned the driver. Conclusions This study indicates that drivers not only attend to an audible warning, but will look at a rear-view camera if available. Evidence suggests that when used appropriately, rear-view cameras can mitigate the occurrence of backing crashes, particularly when paired with an appropriate sensor system. PMID:20363812

  8. Efficacy of a Multi-Component Intervention to Reduce Workplace Sitting Time in Office Workers: A Cluster Randomized Controlled Trial.

    PubMed

    Maylor, Benjamin D; Edwardson, Charlotte L; Zakrzewski-Fruer, Julia K; Champion, Rachael B; Bailey, Daniel P

    2018-05-30

    The aim of this study was to investigate the efficacy of a work-based multicomponent intervention to reduce office workers' sitting time. Offices (n = 12; 89 workers) were randomized into an 8-week intervention (n = 48) incorporating organizational, individual, and environmental elements or control arm. Sitting time, physical activity, and cardiometabolic health were measured at baseline and after the intervention. Linear mixed modelling revealed no significant change in workplace sitting time, but changes in workplace prolonged sitting time (-39 min/shift), sit-upright transitions (7.8 per shift), and stepping time (12 min/shift) at follow-up were observed, in favor of the intervention group (P < 0.001). Results for cardiometabolic health markers were mixed. This short multicomponent workplace intervention was successful in reducing prolonged sitting and increasing physical activity in the workplace, although total sitting time was not reduced and the impact on cardiometabolic health was minimal.

  9. Coincidence ion imaging with a fast frame camera

    NASA Astrophysics Data System (ADS)

    Lee, Suk Kyoung; Cudry, Fadia; Lin, Yun Fei; Lingenfelter, Steven; Winney, Alexander H.; Fan, Lin; Li, Wen

    2014-12-01

    A new time- and position-sensitive particle detection system based on a fast frame CMOS (complementary metal-oxide semiconductors) camera is developed for coincidence ion imaging. The system is composed of four major components: a conventional microchannel plate/phosphor screen ion imager, a fast frame CMOS camera, a single anode photomultiplier tube (PMT), and a high-speed digitizer. The system collects the positional information of ions from a fast frame camera through real-time centroiding while the arrival times are obtained from the timing signal of a PMT processed by a high-speed digitizer. Multi-hit capability is achieved by correlating the intensity of ion spots on each camera frame with the peak heights on the corresponding time-of-flight spectrum of a PMT. Efficient computer algorithms are developed to process camera frames and digitizer traces in real-time at 1 kHz laser repetition rate. We demonstrate the capability of this system by detecting a momentum-matched co-fragments pair (methyl and iodine cations) produced from strong field dissociative double ionization of methyl iodide.

  10. Development of the radial neutron camera system for the HL-2A tokamak

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Y. P., E-mail: zhangyp@swip.ac.cn; Yang, J. W.; Liu, Yi

    2016-06-15

    A new radial neutron camera system has been developed and operated recently in the HL-2A tokamak to measure the spatial and time resolved 2.5 MeV D-D fusion neutron, enhancing the understanding of the energetic-ion physics. The camera mainly consists of a multichannel collimator, liquid-scintillation detectors, shielding systems, and a data acquisition system. Measurements of the D-D fusion neutrons using the camera have been successfully performed during the 2015 HL-2A experiment campaign. The measurements show that the distribution of the fusion neutrons in the HL-2A plasma has a peaked profile, suggesting that the neutral beam injection beam ions in the plasmamore » have a peaked distribution. It also suggests that the neutrons are primarily produced from beam-target reactions in the plasma core region. The measurement results from the neutron camera are well consistent with the results of both a standard {sup 235}U fission chamber and NUBEAM neutron calculations. In this paper, the new radial neutron camera system on HL-2A and the first experimental results are described.« less

  11. Coordinating High-Resolution Traffic Cameras : Developing Intelligent, Collaborating Cameras for Transportation Security and Communications

    DOT National Transportation Integrated Search

    2015-08-01

    Cameras are used prolifically to monitor transportation incidents, infrastructure, and congestion. Traditional camera systems often require human monitoring and only offer low-resolution video. Researchers for the Exploratory Advanced Research (EAR) ...

  12. Analysis of Evaporative On-Board Diagnostic (OBD) Readiness and DTCs Using I/M Data

    EPA Science Inventory

    Gasoline vehicles are equipped with evaporative emissions control systems that control vapor from the fuel storage system while a vehicle is sitting or driving. When these systems or the vehicle’s gasoline delivery system malfunction, excessive evaporative emissions can be emitte...

  13. An improved camera trap for amphibians, reptiles, small mammals, and large invertebrates

    PubMed Central

    2017-01-01

    Camera traps are valuable sampling tools commonly used to inventory and monitor wildlife communities but are challenged to reliably sample small animals. We introduce a novel active camera trap system enabling the reliable and efficient use of wildlife cameras for sampling small animals, particularly reptiles, amphibians, small mammals and large invertebrates. It surpasses the detection ability of commonly used passive infrared (PIR) cameras for this application and eliminates problems such as high rates of false triggers and high variability in detection rates among cameras and study locations. Our system, which employs a HALT trigger, is capable of coupling to digital PIR cameras and is designed for detecting small animals traversing small tunnels, narrow trails, small clearings and along walls or drift fencing. PMID:28981533

  14. Desk-based workers' perspectives on using sit-stand workstations: a qualitative analysis of the Stand@Work study.

    PubMed

    Chau, Josephine Y; Daley, Michelle; Srinivasan, Anu; Dunn, Scott; Bauman, Adrian E; van der Ploeg, Hidde P

    2014-07-25

    Prolonged sitting time has been identified as a health risk factor. Sit-stand workstations allow desk workers to alternate between sitting and standing throughout the working day, but not much is known about their acceptability and feasibility. Hence, the aim of this study was to qualitatively evaluate the acceptability, feasibility and perceptions of using sit-stand workstations in a group of desk-based office workers. This article describes the qualitative evaluation of the randomized controlled cross-over Stand@Work pilot trial. Participants were adult employees recruited from a non-government health agency in Sydney, Australia. The intervention involved using an Ergotron Workfit S sit-stand workstation for four weeks. After the four week intervention, participants shared their perceptions and experiences of using the sit-stand workstation in focus group interviews with 4-5 participants. Topics covered in the focus groups included patterns of workstation use, barriers and facilitators to standing while working, effects on work performance, physical impacts, and feasibility in the office. Focus group field notes and transcripts were analysed in an iterative process during and after the data collection period to identify the main concepts and themes. During nine 45-min focus groups, a total of 42 participants were interviewed. Participants were largely intrinsically motivated to try the sit-stand workstation, mostly because of curiosity to try something new, interest in potential health benefits, and the relevance to the participant's own and organisation's work. Most participants used the sit-stand workstation and three common usage patterns were identified: task-based routine, time-based routine, and no particular routine. Common barriers to sit-stand workstation use were working in an open plan office, and issues with sit-stand workstation design. Common facilitators of sit-stand workstation use were a supportive work environment conducive to standing, perceived physical health benefits, and perceived work benefits. When prompted, most participants indicated they were interested in using a sit-stand workstation in the future. The use of a sit-stand workstation in this group of desk-based office workers was generally perceived as acceptable and feasible. Future studies are needed to explore this in different desk-based work populations and settings.

  15. Temporal changes in occupational sitting time in the Danish workforce and associations with all-cause mortality: results from the Danish work environment cohort study.

    PubMed

    van der Ploeg, Hidde P; Møller, Simone Visbjerg; Hannerz, Harald; van der Beek, Allard J; Holtermann, Andreas

    2015-06-02

    Prolonged sitting has been negatively associated with a range of non-communicably diseases. However, the role of occupational sitting is less clear, and little is known on the changes of occupational sitting in a working population over time. The present study aimed to determine 1) temporal changes in occupational sitting time between 1990 and 2010 in the Danish workforce; 2) the association and possible dose-response relationship between occupational sitting time and all-cause mortality. This study analysed data from the Danish Work Environment Cohort Study (DWECS), which is a cohort study of the Danish working population conducted in five yearly intervals between 1990 and 2010. Occupational sitting time is self-reported in the DWECS. To determine the association with all-cause mortality, the DWECS was linked to the Danish Register of Causes of Death via the Central Person Register. Between 1990 and 2010 the proportion of the Danish workforce who sat for at least three quarters of their work time gradually increased from 33.1 to 39.1%. All-cause mortality analyses were performed with 149,773 person-years of observation and an average follow-up of 12.61 years, during which 533 deaths were registered. None of the presented analyses found a statistically significant association between occupational sitting time and all-cause mortality. The hazard ratio for all-cause mortality was 0.97 (95% CI: 0.79; 1.18) when ≥24 hr/wk occupational sitting time was compared to <24 hr/wk for the 1990-2005 waves. Occupational sitting time increased by 18% in the Danish workforce, which seemed to be limited to people with high socio-economic status. If this increase is accompanied by increases in total sitting time, this development has serious public health implications, given the detrimental associations between total sitting time and mortality. The current study was inconclusive on the specific role that occupational sitting might play in the increased all-cause mortality risk associated with the total volume of sitting.

  16. Engineering study for pallet adapting the Apollo laser altimeter and photographic camera system for the Lidar Test Experiment on orbital flight tests 2 and 4

    NASA Technical Reports Server (NTRS)

    Kuebert, E. J.

    1977-01-01

    A Laser Altimeter and Mapping Camera System was included in the Apollo Lunar Orbital Experiment Missions. The backup system, never used in the Apollo Program, is available for use in the Lidar Test Experiments on the STS Orbital Flight Tests 2 and 4. Studies were performed to assess the problem associated with installation and operation of the Mapping Camera System in the STS. They were conducted on the photographic capabilities of the Mapping Camera System, its mechanical and electrical interface with the STS, documentation, operation and survivability in the expected environments, ground support equipment, test and field support.

  17. Workplace interventions for reducing sitting at work.

    PubMed

    Shrestha, Nipun; Kukkonen-Harjula, Katriina T; Verbeek, Jos H; Ijaz, Sharea; Hermans, Veerle; Pedisic, Zeljko

    2018-06-20

    A large number of people are employed in sedentary occupations. Physical inactivity and excessive sitting at workplaces have been linked to increased risk of cardiovascular disease, obesity, and all-cause mortality. To evaluate the effectiveness of workplace interventions to reduce sitting at work compared to no intervention or alternative interventions. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, CINAHL, OSH UPDATE, PsycINFO, ClinicalTrials.gov, and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) search portal up to 9 August 2017. We also screened reference lists of articles and contacted authors to find more studies. We included randomised controlled trials (RCTs), cross-over RCTs, cluster-randomised controlled trials (cluster-RCTs), and quasi-RCTs of interventions to reduce sitting at work. For changes of workplace arrangements, we also included controlled before-and-after studies. The primary outcome was time spent sitting at work per day, either self-reported or measured using devices such as an accelerometer-inclinometer and duration and number of sitting bouts lasting 30 minutes or more. We considered energy expenditure, total time spent sitting (including sitting at and outside work), time spent standing at work, work productivity and adverse events as secondary outcomes. Two review authors independently screened titles, abstracts and full-text articles for study eligibility. Two review authors independently extracted data and assessed risk of bias. We contacted authors for additional data where required. We found 34 studies - including two cross-over RCTs, 17 RCTs, seven cluster-RCTs, and eight controlled before-and-after studies - with a total of 3,397 participants, all from high-income countries. The studies evaluated physical workplace changes (16 studies), workplace policy changes (four studies), information and counselling (11 studies), and multi-component interventions (four studies). One study included both physical workplace changes and information and counselling components. We did not find any studies that specifically investigated the effects of standing meetings or walking meetings on sitting time.Physical workplace changesInterventions using sit-stand desks, either alone or in combination with information and counselling, reduced sitting time at work on average by 100 minutes per workday at short-term follow-up (up to three months) compared to sit-desks (95% confidence interval (CI) -116 to -84, 10 studies, low-quality evidence). The pooled effect of two studies showed sit-stand desks reduced sitting time at medium-term follow-up (3 to 12 months) by an average of 57 minutes per day (95% CI -99 to -15) compared to sit-desks. Total sitting time (including sitting at and outside work) also decreased with sit-stand desks compared to sit-desks (mean difference (MD) -82 minutes/day, 95% CI -124 to -39, two studies) as did the duration of sitting bouts lasting 30 minutes or more (MD -53 minutes/day, 95% CI -79 to -26, two studies, very low-quality evidence).We found no significant difference between the effects of standing desks and sit-stand desks on reducing sitting at work. Active workstations, such as treadmill desks or cycling desks, had unclear or inconsistent effects on sitting time.Workplace policy changesWe found no significant effects for implementing walking strategies on workplace sitting time at short-term (MD -15 minutes per day, 95% CI -50 to 19, low-quality evidence, one study) and medium-term (MD -17 minutes/day, 95% CI -61 to 28, one study) follow-up. Short breaks (one to two minutes every half hour) reduced time spent sitting at work on average by 40 minutes per day (95% CI -66 to -15, one study, low-quality evidence) compared to long breaks (two 15-minute breaks per workday) at short-term follow-up.Information and counsellingProviding information, feedback, counselling, or all of these resulted in no significant change in time spent sitting at work at short-term follow-up (MD -19 minutes per day, 95% CI -57 to 19, two studies, low-quality evidence). However, the reduction was significant at medium-term follow-up (MD -28 minutes per day, 95% CI -51 to -5, two studies, low-quality evidence).Computer prompts combined with information resulted in no significant change in sitting time at work at short-term follow-up (MD -10 minutes per day, 95% CI -45 to 24, two studies, low-quality evidence), but at medium-term follow-up they produced a significant reduction (MD -55 minutes per day, 95% CI -96 to -14, one study). Furthermore, computer prompting resulted in a significant decrease in the average number (MD -1.1, 95% CI -1.9 to -0.3, one study) and duration (MD -74 minutes per day, 95% CI -124 to -24, one study) of sitting bouts lasting 30 minutes or more.Computer prompts with instruction to stand reduced sitting at work on average by 14 minutes per day (95% CI 10 to 19, one study) more than computer prompts with instruction to walk at least 100 steps at short-term follow-up.We found no significant reduction in workplace sitting time at medium-term follow-up following mindfulness training (MD -23 minutes per day, 95% CI -63 to 17, one study, low-quality evidence). Similarly a single study reported no change in sitting time at work following provision of highly personalised or contextualised information and less personalised or contextualised information. One study found no significant effects of activity trackers on sitting time at work.Multi-component interventions Combining multiple interventions had significant but heterogeneous effects on sitting time at work (573 participants, three studies, very low-quality evidence) and on time spent in prolonged sitting bouts (two studies, very low-quality evidence) at short-term follow-up. At present there is low-quality evidence that the use of sit-stand desks reduce workplace sitting at short-term and medium-term follow-ups. However, there is no evidence on their effects on sitting over longer follow-up periods. Effects of other types of interventions, including workplace policy changes, provision of information and counselling, and multi-component interventions, are mostly inconsistent. The quality of evidence is low to very low for most interventions, mainly because of limitations in study protocols and small sample sizes. There is a need for larger cluster-RCTs with longer-term follow-ups to determine the effectiveness of different types of interventions to reduce sitting time at work.

  18. Utilization and viability of biologically-inspired algorithms in a dynamic multiagent camera surveillance system

    NASA Astrophysics Data System (ADS)

    Mundhenk, Terrell N.; Dhavale, Nitin; Marmol, Salvador; Calleja, Elizabeth; Navalpakkam, Vidhya; Bellman, Kirstie; Landauer, Chris; Arbib, Michael A.; Itti, Laurent

    2003-10-01

    In view of the growing complexity of computational tasks and their design, we propose that certain interactive systems may be better designed by utilizing computational strategies based on the study of the human brain. Compared with current engineering paradigms, brain theory offers the promise of improved self-organization and adaptation to the current environment, freeing the programmer from having to address those issues in a procedural manner when designing and implementing large-scale complex systems. To advance this hypothesis, we discus a multi-agent surveillance system where 12 agent CPUs each with its own camera, compete and cooperate to monitor a large room. To cope with the overload of image data streaming from 12 cameras, we take inspiration from the primate"s visual system, which allows the animal to operate a real-time selection of the few most conspicuous locations in visual input. This is accomplished by having each camera agent utilize the bottom-up, saliency-based visual attention algorithm of Itti and Koch (Vision Research 2000;40(10-12):1489-1506) to scan the scene for objects of interest. Real time operation is achieved using a distributed version that runs on a 16-CPU Beowulf cluster composed of the agent computers. The algorithm guides cameras to track and monitor salient objects based on maps of color, orientation, intensity, and motion. To spread camera view points or create cooperation in monitoring highly salient targets, camera agents bias each other by increasing or decreasing the weight of different feature vectors in other cameras, using mechanisms similar to excitation and suppression that have been documented in electrophysiology, psychophysics and imaging studies of low-level visual processing. In addition, if cameras need to compete for computing resources, allocation of computational time is weighed based upon the history of each camera. A camera agent that has a history of seeing more salient targets is more likely to obtain computational resources. The system demonstrates the viability of biologically inspired systems in a real time tracking. In future work we plan on implementing additional biological mechanisms for cooperative management of both the sensor and processing resources in this system that include top down biasing for target specificity as well as novelty and the activity of the tracked object in relation to sensitive features of the environment.

  19. The effect of sitting and calf activity on leg fluid and snoring.

    PubMed

    Singh, Bhajan; Yadollahi, Azadeh; Lyons, Owen; Alshaer, Hisham; Bradley, T Douglas

    2017-06-01

    Prolonged sitting may promote leg fluid retention that redistributes to the neck during sleep and contributes to snoring. This could be attenuated by calf activity while sitting. In 16 healthy non-obese subjects we measured leg fluid volume (LFV) below the knees using bioelectrical impedance while sitting for 4h, snoring using a portable BresoDx™ device, and Mallampati grade. Using a double cross-over study design, subjects were randomized to one of two arms and crossed-over one week later: control arm - no calf exercise while sitting; intervention arm - calf contraction against a pedal resistance while sitting. The effects of sitting±calf activity on LFV and snoring were compared. We found that LFV increased by 216±101.0ml (p<0.0001) after sitting. Calf activity while sitting attenuated LFV by 53.8ml (p<0.0001) and, in all five subjects with severe upper airway narrowing (Mallampati grade IV), reduced snoring duration (from 357±132.9 to 116.2±72.1s/h, p=0.02) suggesting reduced overnight rostral fluid shift to the neck. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. A telephoto camera system with shooting direction control by gaze detection

    NASA Astrophysics Data System (ADS)

    Teraya, Daiki; Hachisu, Takumi; Yendo, Tomohiro

    2015-05-01

    For safe driving, it is important for driver to check traffic conditions such as traffic lights, or traffic signs as early as soon. If on-vehicle camera takes image of important objects to understand traffic conditions from long distance and shows these to driver, driver can understand traffic conditions earlier. To take image of long distance objects clearly, the focal length of camera must be long. When the focal length is long, on-vehicle camera doesn't have enough field of view to check traffic conditions. Therefore, in order to get necessary images from long distance, camera must have long-focal length and controllability of shooting direction. In previous study, driver indicates shooting direction on displayed image taken by a wide-angle camera, a direction controllable camera takes telescopic image, and displays these to driver. However, driver uses a touch panel to indicate the shooting direction in previous study. It is cause of disturb driving. So, we propose a telephoto camera system for driving support whose shooting direction is controlled by driver's gaze to avoid disturbing drive. This proposed system is composed of a gaze detector and an active telephoto camera whose shooting direction is controlled. We adopt non-wear detecting method to avoid hindrance to drive. The gaze detector measures driver's gaze by image processing. The shooting direction of the active telephoto camera is controlled by galvanometer scanners and the direction can be switched within a few milliseconds. We confirmed that the proposed system takes images of gazing straight ahead of subject by experiments.

  1. What Are the Risks of Sitting Too Much?

    MedlinePlus

    ... that 60 to 75 minutes of moderately intense physical activity a day countered the effects of too much sitting. Another study found that sitting time contributed little to mortality for people who were most ... of sitting and physical activity on health. However, it seems clear that ...

  2. Increasing passive energy expenditure during clerical work.

    PubMed

    Beers, Erik A; Roemmich, James N; Epstein, Leonard H; Horvath, Peter J

    2008-06-01

    Sitting on a therapy ball or standing may be a passive means of increasing energy expenditure throughout the workday. The purpose of this study was to determine the energy expenditure and liking of performing clerical work in various postures. Subjects included 24 men and women employed in sedentary clerical occupations. Energy expenditure was measured while word processing in three standardized postures; sitting in an office chair, sitting on a therapy ball, and standing. Adults ranked their comfort, fatigue, and liking of each posture and were asked to perform their choice of 20 min of additional clerical work in one of the postures. Energy expenditure was 4.1 kcal/h greater (p or= 0.48). Subjects also liked sitting on a therapy ball as much as sitting in an office chair and liked sitting on a therapy ball more than standing (p

  3. SPARTAN Near-IR Camera | SOAR

    Science.gov Websites

    SPARTAN Near-IR Camera SPARTAN Cookbook Ohio State Infrared Imager/Spectrograph (OSIRIS) - NO LONGER Instrumentation at SOAR»SPARTAN Near-IR Camera SPARTAN Near-IR Camera System Overview The Spartan Infrared Camera is a high spatial resolution near-IR imager. Spartan has a focal plane conisisting of four "

  4. Control system for several rotating mirror camera synchronization operation

    NASA Astrophysics Data System (ADS)

    Liu, Ningwen; Wu, Yunfeng; Tan, Xianxiang; Lai, Guoji

    1997-05-01

    This paper introduces a single chip microcomputer control system for synchronization operation of several rotating mirror high-speed cameras. The system consists of four parts: the microcomputer control unit (including the synchronization part and precise measurement part and the time delay part), the shutter control unit, the motor driving unit and the high voltage pulse generator unit. The control system has been used to control the synchronization working process of the GSI cameras (driven by a motor) and FJZ-250 rotating mirror cameras (driven by a gas driven turbine). We have obtained the films of the same objective from different directions in different speed or in same speed.

  5. Evaluation of the MSFC facsimile camera system as a tool for extraterrestrial geologic exploration

    NASA Technical Reports Server (NTRS)

    Wolfe, E. W.; Alderman, J. D.

    1971-01-01

    Utility of the Marshall Space Flight (MSFC) facsimile camera system for extraterrestrial geologic exploration was investigated during the spring of 1971 near Merriam Crater in northern Arizona. Although the system with its present hard-wired recorder operates erratically, the imagery showed that the camera could be developed as a prime imaging tool for automated missions. Its utility would be enhanced by development of computer techniques that utilize digital camera output for construction of topographic maps, and it needs increased resolution for examining near field details. A supplementary imaging system may be necessary for hand specimen examination at low magnification.

  6. The use of consumer depth cameras for 3D surface imaging of people with obesity: A feasibility study.

    PubMed

    Wheat, J S; Clarkson, S; Flint, S W; Simpson, C; Broom, D R

    2018-05-21

    Three dimensional (3D) surface imaging is a viable alternative to traditional body morphology measures, but the feasibility of using this technique with people with obesity has not been fully established. Therefore, the aim of this study was to investigate the validity, repeatability and acceptability of a consumer depth camera 3D surface imaging system in imaging people with obesity. The concurrent validity of the depth camera based system was investigated by comparing measures of mid-trunk volume to a gold-standard. The repeatability and acceptability of the depth camera system was assessed in people with obesity at a clinic. There was evidence of a fixed systematic difference between the depth camera system and the gold standard but excellent correlation between volume estimates (r 2 =0.997), with little evidence of proportional bias. The depth camera system was highly repeatable - low typical error (0.192L), high intraclass correlation coefficient (>0.999) and low technical error of measurement (0.64%). Depth camera based 3D surface imaging was also acceptable to people with obesity. It is feasible (valid, repeatable and acceptable) to use a low cost, flexible 3D surface imaging system to monitor the body size and shape of people with obesity in a clinical setting. Copyright © 2018 Asia Oceania Association for the Study of Obesity. Published by Elsevier Ltd. All rights reserved.

  7. Development of a camera casing suited for cryogenic and vacuum applications

    NASA Astrophysics Data System (ADS)

    Delaquis, S. C.; Gornea, R.; Janos, S.; Lüthi, M.; von Rohr, Ch Rudolf; Schenk, M.; Vuilleumier, J.-L.

    2013-12-01

    We report on the design, construction, and operation of a PID temperature controlled and vacuum tight camera casing. The camera casing contains a commercial digital camera and a lighting system. The design of the camera casing and its components are discussed in detail. Pictures taken by this cryo-camera while immersed in argon vapour and liquid nitrogen are presented. The cryo-camera can provide a live view inside cryogenic set-ups and allows to record video.

  8. Use and validation of mirrorless digital single light reflex camera for recording of vitreoretinal surgeries in high definition

    PubMed Central

    Khanduja, Sumeet; Sampangi, Raju; Hemlatha, B C; Singh, Satvir; Lall, Ashish

    2018-01-01

    Purpose: The purpose of this study is to describe the use of commercial digital single light reflex (DSLR) for vitreoretinal surgery recording and compare it to standard 3-chip charged coupling device (CCD) camera. Methods: Simultaneous recording was done using Sony A7s2 camera and Sony high-definition 3-chip camera attached to each side of the microscope. The videos recorded from both the camera systems were edited and sequences of similar time frames were selected. Three sequences that selected for evaluation were (a) anterior segment surgery, (b) surgery under direct viewing system, and (c) surgery under indirect wide-angle viewing system. The videos of each sequence were evaluated and rated on a scale of 0-10 for color, contrast, and overall quality Results: Most results were rated either 8/10 or 9/10 for both the cameras. A noninferiority analysis by comparing mean scores of DSLR camera versus CCD camera was performed and P values were obtained. The mean scores of the two cameras were comparable for each other on all parameters assessed in the different videos except of color and contrast in posterior pole view and color on wide-angle view, which were rated significantly higher (better) in DSLR camera. Conclusion: Commercial DSLRs are an affordable low-cost alternative for vitreoretinal surgery recording and may be used for documentation and teaching. PMID:29283133

  9. Use and validation of mirrorless digital single light reflex camera for recording of vitreoretinal surgeries in high definition.

    PubMed

    Khanduja, Sumeet; Sampangi, Raju; Hemlatha, B C; Singh, Satvir; Lall, Ashish

    2018-01-01

    The purpose of this study is to describe the use of commercial digital single light reflex (DSLR) for vitreoretinal surgery recording and compare it to standard 3-chip charged coupling device (CCD) camera. Simultaneous recording was done using Sony A7s2 camera and Sony high-definition 3-chip camera attached to each side of the microscope. The videos recorded from both the camera systems were edited and sequences of similar time frames were selected. Three sequences that selected for evaluation were (a) anterior segment surgery, (b) surgery under direct viewing system, and (c) surgery under indirect wide-angle viewing system. The videos of each sequence were evaluated and rated on a scale of 0-10 for color, contrast, and overall quality Results: Most results were rated either 8/10 or 9/10 for both the cameras. A noninferiority analysis by comparing mean scores of DSLR camera versus CCD camera was performed and P values were obtained. The mean scores of the two cameras were comparable for each other on all parameters assessed in the different videos except of color and contrast in posterior pole view and color on wide-angle view, which were rated significantly higher (better) in DSLR camera. Commercial DSLRs are an affordable low-cost alternative for vitreoretinal surgery recording and may be used for documentation and teaching.

  10. Fear on the move: predator hunting mode predicts variation in prey mortality and plasticity in prey spatial response.

    PubMed

    Miller, Jennifer R B; Ament, Judith M; Schmitz, Oswald J

    2014-01-01

    Ecologists have long searched for a framework of a priori species traits to help predict predator-prey interactions in food webs. Empirical evidence has shown that predator hunting mode and predator and prey habitat domain are useful traits for explaining predator-prey interactions. Yet, individual experiments have yet to replicate predator hunting mode, calling into question whether predator impacts can be attributed to hunting mode or merely species identity. We tested the effects of spider predators with sit-and-wait, sit-and-pursue and active hunting modes on grasshopper habitat domain, activity and mortality in a grassland system. We replicated hunting mode by testing two spider predator species of each hunting mode on the same grasshopper prey species. We observed grasshoppers with and without each spider species in behavioural cages and measured their mortality rates, movements and habitat domains. We likewise measured the movements and habitat domains of spiders to characterize hunting modes. We found that predator hunting mode explained grasshopper mortality and spider and grasshopper movement activity and habitat domain size. Sit-and-wait spider predators covered small distances over a narrow domain space and killed fewer grasshoppers than sit-and-pursue and active predators, which ranged farther distances across broader domains and killed more grasshoppers, respectively. Prey adjusted their activity levels and horizontal habitat domains in response to predator presence and hunting mode: sedentary sit-and-wait predators with narrow domains caused grasshoppers to reduce activity in the same-sized domain space; more mobile sit-and-pursue predators with broader domains caused prey to reduce their activity within a contracted horizontal (but not vertical) domain space; and highly mobile active spiders led grasshoppers to increase their activity across the same domain area. All predators impacted prey activity, and sit-and-pursue predators generated strong effects on domain size. This study demonstrates the validity of utilizing hunting mode and habitat domain for predicting predator-prey interactions. Results also highlight the importance of accounting for flexibility in prey movement ranges as an anti-predator response rather than treating the domain as a static attribute. © 2013 The Authors. Journal of Animal Ecology © 2013 British Ecological Society.

  11. A Rapid Monitoring and Evaluation Method of Schistosomiasis Based on Spatial Information Technology.

    PubMed

    Wang, Yong; Zhuang, Dafang

    2015-12-12

    Thanks to Spatial Information Technologies (SITs) such as Remote Sensing (RS) and Geographical Information System (GIS) that are being quickly developed and updated, SITs are being used more widely in the public health field. The use of SITs to study the characteristics of the temporal and spatial distribution of Schistosoma japonicum and to assess the risk of infection provides methods for the control and prevention of schistosomiasis japonica has gradually become a hot topic in the field. The purpose of the present paper was to use RS and GIS technology to develop an efficient method of prediction and assessment of the risk of schistosomiasis japonica. We choose the Yueyang region, close to the east DongTing Lake (Hunan Province, China), as the study area, where a recent serious outbreak of schistosomiasis japonica took place. We monitored and evaluated the transmission risk of schistosomiasis japonica in the region using SITs. Water distribution data were extracted from RS images. The ground temperature, ground humidity and vegetation index were calculated based on RS images. Additionally, the density of oncomelania snails, which are the Schistosoma japonicum intermediate host, was calculated on the base of RS data and field measurements. The spatial distribution of oncomelania snails was explored using SITs in order to estimate the area surrounding the residents with transmission risk of schistosomiasis japonica. Our research result demonstrated: (1) the risk factors for the transmission of schistosomiasis japonica were closely related to the living environment of oncomelania snails. Key factors such as water distribution, ground temperature, ground humidity and vegetation index can be quickly obtained and calculated from RS images; (2) using GIS technology and a RS deduction technique along with statistical regression models, the density distribution model of oncomelania snails could be quickly built; (3) using SITs and analysis with overlaying population distribution data, the range of transmission risk of schistosomiasis japonica of the study area can be quickly monitored and evaluated. This method will help support the decision making for the control and prevention of schistosomiasis and form a valuable application using SITs for the schistosomiasis research.

  12. A high-speed digital camera system for the observation of rapid H-alpha fluctuations in solar flares

    NASA Technical Reports Server (NTRS)

    Kiplinger, Alan L.; Dennis, Brian R.; Orwig, Larry E.

    1989-01-01

    Researchers developed a prototype digital camera system for obtaining H-alpha images of solar flares with 0.1 s time resolution. They intend to operate this system in conjunction with SMM's Hard X Ray Burst Spectrometer, with x ray instruments which will be available on the Gamma Ray Observatory and eventually with the Gamma Ray Imaging Device (GRID), and with the High Resolution Gamma-Ray and Hard X Ray Spectrometer (HIREGS) which are being developed for the Max '91 program. The digital camera has recently proven to be successful as a one camera system operating in the blue wing of H-alpha during the first Max '91 campaign. Construction and procurement of a second and possibly a third camera for simultaneous observations at other wavelengths are underway as are analyses of the campaign data.

  13. Using the Newly Developed Floor-Sitting Movement Analysis Proforma to Study the Effect of Age and Activity on Floor-Sitting in Indian Adults.

    PubMed

    Nagrajan, Anjana; D'Souza, Sebestina A

    2017-03-01

    Floor-sitting is culturally relevant to the Indian context. The present study aimed to examine the effect of age and activity on the movement patterns used and time taken to perform floor-sitting in Indian adults. Video-recordings of 30 young (23.30 ± 2.53 years) and 30 older (69.67 ± 6.45 years) adults performing floor-sitting without and with an activity (simulated feeding) were analyzed using the Floor-sitting Movement Analysis Proforma (FMAP) developed for the study. For inter-rater reliability of the FMAP, two raters analyzed the performance of a random sample of 20 participants. An almost perfect inter-rater agreeability (κ ≥ .8) was obtained for the FMAP. Cross-legged sitting was the most preferred (95%) floor-sitting position. Older adults used more number of movement components, asymmetrical patterns, more support, and more time (p < .001) as compared to the young adults. The activity facilitated the use of optimal movement strategies in young and older adults. The activity significantly increased time taken to rise from floor-sitting (p = .004). The study establishes the influence of age and activity on performance of floor-sitting. Older adults use lower developmental movement patterns that may be a "normal" adaptation to age-related sensorimotor changes. Retraining of floor-sitting is a "culturally" desired goal among Indian adults and should involve the practice of age-appropriate movement patterns in the context of meaningful activities.

  14. The Evolution of Silicon Transport in Eukaryotes

    PubMed Central

    Marron, Alan O.; Ratcliffe, Sarah; Wheeler, Glen L.; Goldstein, Raymond E.; King, Nicole; Not, Fabrice; de Vargas, Colomban; Richter, Daniel J.

    2016-01-01

    Biosilicification (the formation of biological structures from silica) occurs in diverse eukaryotic lineages, plays a major role in global biogeochemical cycles, and has significant biotechnological applications. Silicon (Si) uptake is crucial for biosilicification, yet the evolutionary history of the transporters involved remains poorly known. Recent evidence suggests that the SIT family of Si transporters, initially identified in diatoms, may be widely distributed, with an extended family of related transporters (SIT-Ls) present in some nonsilicified organisms. Here, we identify SITs and SIT-Ls in a range of eukaryotes, including major silicified lineages (radiolarians and chrysophytes) and also bacterial SIT-Ls. Our evidence suggests that the symmetrical 10-transmembrane-domain SIT structure has independently evolved multiple times via duplication and fusion of 5-transmembrane-domain SIT-Ls. We also identify a second gene family, similar to the active Si transporter Lsi2, that is broadly distributed amongst siliceous and nonsiliceous eukaryotes. Our analyses resolve a distinct group of Lsi2-like genes, including plant and diatom Si-responsive genes, and sequences unique to siliceous sponges and choanoflagellates. The SIT/SIT-L and Lsi2 transporter families likely contribute to biosilicification in diverse lineages, indicating an ancient role for Si transport in eukaryotes. We propose that these Si transporters may have arisen initially to prevent Si toxicity in the high Si Precambrian oceans, with subsequent biologically induced reductions in Si concentrations of Phanerozoic seas leading to widespread losses of SIT, SIT-L, and Lsi2-like genes in diverse lineages. Thus, the origin and diversification of two independent Si transporter families both drove and were driven by ancient ocean Si levels. PMID:27729397

  15. Accuracy Potential and Applications of MIDAS Aerial Oblique Camera System

    NASA Astrophysics Data System (ADS)

    Madani, M.

    2012-07-01

    Airborne oblique cameras such as Fairchild T-3A were initially used for military reconnaissance in 30s. A modern professional digital oblique camera such as MIDAS (Multi-camera Integrated Digital Acquisition System) is used to generate lifelike three dimensional to the users for visualizations, GIS applications, architectural modeling, city modeling, games, simulators, etc. Oblique imagery provide the best vantage for accessing and reviewing changes to the local government tax base, property valuation assessment, buying & selling of residential/commercial for better decisions in a more timely manner. Oblique imagery is also used for infrastructure monitoring making sure safe operations of transportation, utilities, and facilities. Sanborn Mapping Company acquired one MIDAS from TrackAir in 2011. This system consists of four tilted (45 degrees) cameras and one vertical camera connected to a dedicated data acquisition computer system. The 5 digital cameras are based on the Canon EOS 1DS Mark3 with Zeiss lenses. The CCD size is 5,616 by 3,744 (21 MPixels) with the pixel size of 6.4 microns. Multiple flights using different camera configurations (nadir/oblique (28 mm/50 mm) and (50 mm/50 mm)) were flown over downtown Colorado Springs, Colorado. Boresight fights for 28 mm nadir camera were flown at 600 m and 1,200 m and for 50 mm nadir camera at 750 m and 1500 m. Cameras were calibrated by using a 3D cage and multiple convergent images utilizing Australis model. In this paper, the MIDAS system is described, a number of real data sets collected during the aforementioned flights are presented together with their associated flight configurations, data processing workflow, system calibration and quality control workflows are highlighted and the achievable accuracy is presented in some detail. This study revealed that the expected accuracy of about 1 to 1.5 GSD (Ground Sample Distance) for planimetry and about 2 to 2.5 GSD for vertical can be achieved. Remaining systematic errors were modeled by analyzing residuals using correction grid. The results of the final bundle adjustments are sufficient to enable Sanborn to produce DEM/DTM and orthophotos from the nadir imagery and create 3D models using georeferenced oblique imagery.

  16. Compensation for positioning error of industrial robot for flexible vision measuring system

    NASA Astrophysics Data System (ADS)

    Guo, Lei; Liang, Yajun; Song, Jincheng; Sun, Zengyu; Zhu, Jigui

    2013-01-01

    Positioning error of robot is a main factor of accuracy of flexible coordinate measuring system which consists of universal industrial robot and visual sensor. Present compensation methods for positioning error based on kinematic model of robot have a significant limitation that it isn't effective in the whole measuring space. A new compensation method for positioning error of robot based on vision measuring technique is presented. One approach is setting global control points in measured field and attaching an orientation camera to vision sensor. Then global control points are measured by orientation camera to calculate the transformation relation from the current position of sensor system to global coordinate system and positioning error of robot is compensated. Another approach is setting control points on vision sensor and two large field cameras behind the sensor. Then the three dimensional coordinates of control points are measured and the pose and position of sensor is calculated real-timely. Experiment result shows the RMS of spatial positioning is 3.422mm by single camera and 0.031mm by dual cameras. Conclusion is arithmetic of single camera method needs to be improved for higher accuracy and accuracy of dual cameras method is applicable.

  17. PubMed Central

    Baum, S.; Sillem, M.; Ney, J. T.; Baum, A.; Friedrich, M.; Radosa, J.; Kramer, K. M.; Gronwald, B.; Gottschling, S.; Solomayer, E. F.; Rody, A.; Joukhadar, R.

    2017-01-01

    Introduction Minimally invasive operative techniques are being used increasingly in gynaecological surgery. The expansion of the laparoscopic operation spectrum is in part the result of improved imaging. This study investigates the practical advantages of using 3D cameras in routine surgical practice. Materials and Methods Two different 3-dimensional camera systems were compared with a 2-dimensional HD system; the operating surgeonʼs experiences were documented immediately postoperatively using a questionnaire. Results Significant advantages were reported for suturing and cutting of anatomical structures when using the 3D compared to 2D camera systems. There was only a slight advantage for coagulating. The use of 3D cameras significantly improved the general operative visibility and in particular the representation of spacial depth compared to 2-dimensional images. There was not a significant advantage for image width. Depiction of adhesions and retroperitoneal neural structures was significantly improved by the stereoscopic cameras, though this did not apply to blood vessels, ureter, uterus or ovaries. Conclusion 3-dimensional cameras were particularly advantageous for the depiction of fine anatomical structures due to improved spacial depth representation compared to 2D systems. 3D cameras provide the operating surgeon with a monitor image that more closely resembles actual anatomy, thus simplifying laparoscopic procedures. PMID:28190888

  18. Analysis of edge density fluctuation measured by trial KSTAR beam emission spectroscopy systema)

    NASA Astrophysics Data System (ADS)

    Nam, Y. U.; Zoletnik, S.; Lampert, M.; Kovácsik, Á.

    2012-10-01

    A beam emission spectroscopy (BES) system based on direct imaging avalanche photodiode (APD) camera has been designed for Korea Superconducting Tokamak Advanced Research (KSTAR) and a trial system has been constructed and installed for evaluating feasibility of the design. The system contains two cameras, one is an APD camera for BES measurement and another is a fast visible camera for position calibration. Two pneumatically actuated mirrors were positioned at front and rear of lens optics. The front mirror can switch the measurement between edge and core region of plasma and the rear mirror can switch between the APD and the visible camera. All systems worked properly and the measured photon flux was reasonable as expected from the simulation. While the measurement data from the trial system were limited, it revealed some interesting characteristics of KSTAR plasma suggesting future research works with fully installed BES system. The analysis result and the development plan will be presented in this paper.

  19. Real-time tracking and fast retrieval of persons in multiple surveillance cameras of a shopping mall

    NASA Astrophysics Data System (ADS)

    Bouma, Henri; Baan, Jan; Landsmeer, Sander; Kruszynski, Chris; van Antwerpen, Gert; Dijk, Judith

    2013-05-01

    The capability to track individuals in CCTV cameras is important for e.g. surveillance applications at large areas such as train stations, airports and shopping centers. However, it is laborious to track and trace people over multiple cameras. In this paper, we present a system for real-time tracking and fast interactive retrieval of persons in video streams from multiple static surveillance cameras. This system is demonstrated in a shopping mall, where the cameras are positioned without overlapping fields-of-view and have different lighting conditions. The results show that the system allows an operator to find the origin or destination of a person more efficiently. The misses are reduced with 37%, which is a significant improvement.

  20. FPGA Based Adaptive Rate and Manifold Pattern Projection for Structured Light 3D Camera System †

    PubMed Central

    Lee, Sukhan

    2018-01-01

    The quality of the captured point cloud and the scanning speed of a structured light 3D camera system depend upon their capability of handling the object surface of a large reflectance variation in the trade-off of the required number of patterns to be projected. In this paper, we propose and implement a flexible embedded framework that is capable of triggering the camera single or multiple times for capturing single or multiple projections within a single camera exposure setting. This allows the 3D camera system to synchronize the camera and projector even for miss-matched frame rates such that the system is capable of projecting different types of patterns for different scan speed applications. This makes the system capturing a high quality of 3D point cloud even for the surface of a large reflectance variation while achieving a high scan speed. The proposed framework is implemented on the Field Programmable Gate Array (FPGA), where the camera trigger is adaptively generated in such a way that the position and the number of triggers are automatically determined according to camera exposure settings. In other words, the projection frequency is adaptive to different scanning applications without altering the architecture. In addition, the proposed framework is unique as it does not require any external memory for storage because pattern pixels are generated in real-time, which minimizes the complexity and size of the application-specific integrated circuit (ASIC) design and implementation. PMID:29642506

  1. Combined use of a priori data for fast system self-calibration of a non-rigid multi-camera fringe projection system

    NASA Astrophysics Data System (ADS)

    Stavroulakis, Petros I.; Chen, Shuxiao; Sims-Waterhouse, Danny; Piano, Samanta; Southon, Nicholas; Bointon, Patrick; Leach, Richard

    2017-06-01

    In non-rigid fringe projection 3D measurement systems, where either the camera or projector setup can change significantly between measurements or the object needs to be tracked, self-calibration has to be carried out frequently to keep the measurements accurate1. In fringe projection systems, it is common to use methods developed initially for photogrammetry for the calibration of the camera(s) in the system in terms of extrinsic and intrinsic parameters. To calibrate the projector(s) an extra correspondence between a pre-calibrated camera and an image created by the projector is performed. These recalibration steps are usually time consuming and involve the measurement of calibrated patterns on planes, before the actual object can continue to be measured after a motion of a camera or projector has been introduced in the setup and hence do not facilitate fast 3D measurement of objects when frequent experimental setup changes are necessary. By employing and combining a priori information via inverse rendering, on-board sensors, deep learning and leveraging a graphics processor unit (GPU), we assess a fine camera pose estimation method which is based on optimising the rendering of a model of a scene and the object to match the view from the camera. We find that the success of this calibration pipeline can be greatly improved by using adequate a priori information from the aforementioned sources.

  2. The efficacy of the new SCD response compression system in the prevention of venous stasis.

    PubMed

    Kakkos, S K; Szendro, G; Griffin, M; Daskalopoulou, S S; Nicolaides, A N

    2000-11-01

    The current commercially available sequential intermittent pneumatic compression device used for the prevention of deep venous thrombosis has a constant cycle of 11 seconds' compression and 60 seconds' deflation. This deflation period ensures that the veins are filled before the subsequent cycle begins. It has been suggested that in some positions (eg, semirecumbent or sitting) and with different patients (eg, those with venous reflux), refilling of the veins may occur much earlier than 60 seconds, and thus a more frequent cycle may be more effective in expelling blood proximally. The aim of the study was to test the effectiveness of a new sequential compression system (the SCD Response Compression System), which has the ability to detect the change in the venous volume and to respond by initiating the subsequent cycle when the veins are substantially full. In an open controlled trial at an academic vascular laboratory, the SCD Response Compression System was tested against the existing SCD Sequel Compression System in 12 healthy volunteers who were in supine, semirecumbent, and sitting positions. The refilling time sensed by the device was compared with that determined from recordings of femoral vein flow velocity by the use of duplex ultrasound scan. The total volume of blood expelled per hour during compression was compared with that produced by the existing SCD system in the same volunteers and positions. The refilling time determined automatically by the SCD Response Compression System varied from 24 to 60 seconds in the subjects tested, demonstrating individual patient variation. The refilling time (mean +/- SD) in the sitting position was 40.6 +/- 10. 0 seconds, which was significantly longer (P <.001) than that measured in the supine and semirecumbent positions, 33.8 +/- 4.1 and 35.6 +/- 4.9 seconds, respectively. There was a linear relationship between the duplex scan-derived refill time (mean of 6 readings per leg) and the SCD Response device-derived refill time (r = 0.85, P <. 001). The total volume of blood (mean +/- SD) expelled per hour by the existing SCD Sequel device in the supine, semirecumbent, and sitting positions was 2.23 +/- 0.90 L/h, 2.47 +/- 0.86 L/h, and 3.28 +/- 1.24 L/h, respectively. The SCD Response device increased the volume expelled to 3.92 +/- 1.60 L/h or a 76% increase (P =.001) in the supine position, to 3.93 +/- 1.55 L/h or a 59% increase (P =. 001) in the semirecumbent position, and to 3.97 +/- 1.42 L/h or a 21% increase (P =.026) in the sitting position. By achieving more appropriately timed compression cycles over time, the new SCD Response System is effective in preventing venous stasis by means of a new method that improves on the clinically documented effectiveness of the existing SCD system. Further studies testing its potential for improved efficacy in preventing deep venous thrombosis are justified.

  3. Alternative images for perpendicular parking : a usability test of a multi-camera parking assistance system.

    DOT National Transportation Integrated Search

    2004-10-01

    The parking assistance system evaluated consisted of four outward facing cameras whose images could be presented on a monitor on the center console. The images presented varied in the location of the virtual eye point of the camera (the height above ...

  4. A low-cost dual-camera imaging system for aerial applicators

    USDA-ARS?s Scientific Manuscript database

    Agricultural aircraft provide a readily available remote sensing platform as low-cost and easy-to-use consumer-grade cameras are being increasingly used for aerial imaging. In this article, we report on a dual-camera imaging system we recently assembled that can capture RGB and near-infrared (NIR) i...

  5. An examination of the comfort and convenience of 1979 safety belt systems

    DOT National Transportation Integrated Search

    1979-01-01

    The study examines the comfort and convenience aspects of safety belt systems in 1979 model cars and the user and system characteristics which affect safety belt comfort and convenience. The test design required that each of 114 test participants sit...

  6. A smart telerobotic system driven by monocular vision

    NASA Technical Reports Server (NTRS)

    Defigueiredo, R. J. P.; Maccato, A.; Wlczek, P.; Denney, B.; Scheerer, J.

    1994-01-01

    A robotic system that accepts autonomously generated motion and control commands is described. The system provides images from the monocular vision of a camera mounted on a robot's end effector, eliminating the need for traditional guidance targets that must be predetermined and specifically identified. The telerobotic vision system presents different views of the targeted object relative to the camera, based on a single camera image and knowledge of the target's solid geometry.

  7. Issues in implementing services for a wireless web-enabled digital camera

    NASA Astrophysics Data System (ADS)

    Venkataraman, Shyam; Sampat, Nitin; Fisher, Yoram; Canosa, John; Noel, Nicholas

    2001-05-01

    The competition in the exploding digital photography market has caused vendors to explore new ways to increase their return on investment. A common view among industry analysts is that increasingly it will be services provided by these cameras, and not the cameras themselves, that will provide the revenue stream. These services will be coupled to e- Appliance based Communities. In addition, the rapidly increasing need to upload images to the Internet for photo- finishing services as well as the need to download software upgrades to the camera is driving many camera OEMs to evaluate the benefits of using the wireless web to extend their enterprise systems. Currently, creating a viable e- appliance such as a digital camera coupled with a wireless web service requires more than just a competency in product development. This paper will evaluate the system implications in the deployment of recurring revenue services and enterprise connectivity of a wireless, web-enabled digital camera. These include, among other things, an architectural design approach for services such as device management, synchronization, billing, connectivity, security, etc. Such an evaluation will assist, we hope, anyone designing or connecting a digital camera to the enterprise systems.

  8. Very High-Speed Digital Video Capability for In-Flight Use

    NASA Technical Reports Server (NTRS)

    Corda, Stephen; Tseng, Ting; Reaves, Matthew; Mauldin, Kendall; Whiteman, Donald

    2006-01-01

    digital video camera system has been qualified for use in flight on the NASA supersonic F-15B Research Testbed aircraft. This system is capable of very-high-speed color digital imaging at flight speeds up to Mach 2. The components of this system have been ruggedized and shock-mounted in the aircraft to survive the severe pressure, temperature, and vibration of the flight environment. The system includes two synchronized camera subsystems installed in fuselage-mounted camera pods (see Figure 1). Each camera subsystem comprises a camera controller/recorder unit and a camera head. The two camera subsystems are synchronized by use of an MHub(TradeMark) synchronization unit. Each camera subsystem is capable of recording at a rate up to 10,000 pictures per second (pps). A state-of-the-art complementary metal oxide/semiconductor (CMOS) sensor in the camera head has a maximum resolution of 1,280 1,024 pixels at 1,000 pps. Exposure times of the electronic shutter of the camera range from 1/200,000 of a second to full open. The recorded images are captured in a dynamic random-access memory (DRAM) and can be downloaded directly to a personal computer or saved on a compact flash memory card. In addition to the high-rate recording of images, the system can display images in real time at 30 pps. Inter Range Instrumentation Group (IRIG) time code can be inserted into the individual camera controllers or into the M-Hub unit. The video data could also be used to obtain quantitative, three-dimensional trajectory information. The first use of this system was in support of the Space Shuttle Return to Flight effort. Data were needed to help in understanding how thermally insulating foam is shed from a space shuttle external fuel tank during launch. The cameras captured images of simulated external tank debris ejected from a fixture mounted under the centerline of the F-15B aircraft. Digital video was obtained at subsonic and supersonic flight conditions, including speeds up to Mach 2 and altitudes up to 50,000 ft (15.24 km). The digital video was used to determine the structural survivability of the debris in a real flight environment and quantify the aerodynamic trajectories of the debris.

  9. Patients with sacroiliac joint dysfunction exhibit altered movement strategies when performing a sit-to-stand task.

    PubMed

    Capobianco, Robyn A; Feeney, Daniel F; Jeffers, Jana R; Nelson-Wong, Erika; Morreale, Joseph; Grabowski, Alena M; Enoka, Roger M

    2018-04-03

    The ability to rise from a chair is a basic functional task that is frequently compromised in individuals diagnosed with orthopedic disorders in the low back and hip. There is no published literature that describes how this task is altered by sacroiliac joint dysfunction (SIJD). The objective of this study was to compare lower extremity biomechanics and the onset of muscle activity when rising from a chair in subjects with SIJD and in healthy persons. Six women with unilateral SIJD and six age-matched healthy controls performed a sit-to-stand task while we measured kinematics, kinetics, and muscle activity. Subjects stood up at a preferred speed from a seated position on an armless and backless adjustable stool. We measured kinematics with a 10-camera motion capture system, ground reaction forces for each leg with force plates, and muscle activity with surface electromyography. Joint angles and torques were calculated using inverse dynamics. Leg-loading rate was quantified as the average slope of vertical ground reaction (VGRF) force during the 500-millisecond interval preceding maximal knee extension. Between-leg differences in loading rates and peak VGRFs were significantly greater for the SIJD group than for the control group. Maximal hip angles were significantly less for the SIJD group (p=.001). Peak hip moment in the SIJD group was significantly greater in the unaffected leg (0.75±0.22 N⋅m/kg) than in the affected leg (0.47±0.29 N⋅m/kg, p=.005). There were no between-leg or between-group differences for peak knee or ankle moments. The onset of activity in the latissimus dorsi muscle on the affected side was delayed and the erector spinae muscles were activated earlier in the SIJD group than in the control group. Subjects with SIJD have a greater VGRF on the unaffected leg, generate a greater peak hip moment in the unaffected leg, use a smaller range of motion at the hip joint of the affected leg, and delay the onset of a key muscle on the affected side when rising from a seated position. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Yeast species associated with orange juice: evaluation of different identification methods.

    PubMed

    Arias, Covadonga R; Burns, Jacqueline K; Friedrich, Lorrie M; Goodrich, Renee M; Parish, Mickey E

    2002-04-01

    Five different methods were used to identify yeast isolates from a variety of citrus juice sources. A total of 99 strains, including reference strains, were identified using a partial sequence of the 26S rRNA gene, restriction pattern analysis of the internal transcribed spacer region (5.8S-ITS), classical methodology, the RapID Yeast Plus system, and API 20C AUX. Twenty-three different species were identified representing 11 different genera. Distribution of the species was considerably different depending on the type of sample. Fourteen different species were identified from pasteurized single-strength orange juice that had been contaminated after pasteurization (PSOJ), while only six species were isolated from fresh-squeezed, unpasteurized orange juice (FSOJ). Among PSOJ isolates, Candida intermedia and Candida parapsilosis were the predominant species. Hanseniaspora occidentalis and Hanseniaspora uvarum represented up to 73% of total FSOJ isolates. Partial sequence of the 26S rRNA gene yielded the best results in terms of correct identification, followed by classical techniques and 5.8S-ITS analysis. The commercial identification kits RapID Yeast Plus system and API 20C AUX were able to correctly identify only 35 and 13% of the isolates, respectively. Six new 5.8S-ITS profiles were described, corresponding to Clavispora lusitaniae, Geotrichum citri-aurantii, H. occidentalis, H. vineae, Pichia fermentans, and Saccharomycopsis crataegensis. With the addition of these new profiles to the existing database, the use of 5.8S-ITS sequence became the best tool for rapid and accurate identification of yeast isolates from orange juice.

  11. Bandit: Technologies for Proximity Operations of Teams of Sub-10Kg Spacecraft

    DTIC Science & Technology

    2007-10-16

    and adding a dedicated overhead camera system. As will be explained below, the forced-air system did not work and the existing system has proven too...erratic to justify the expense of the camera system. 6DOF Software Simulator. The existing Java-based graphical 6DOF simulator was to be improved for...proposed camera system for a nonfunctional table. The C-9 final report is enclosed. ["Prf flj ,er Figure 1. Forced-air table schematic Figure 2

  12. A Lower Limb Rehabilitation Robot in Sitting Position with a Review of Training Activities.

    PubMed

    Eiammanussakul, Trinnachoke; Sangveraphunsiri, Viboon

    2018-01-01

    Robots for stroke rehabilitation at the lower limbs in sitting/lying position have been developed extensively. Some of them have been applied in clinics and shown the potential of the recovery of poststroke patients who suffer from hemiparesis. These robots were developed to provide training at different joints of lower limbs with various activities and modalities. This article reviews the training activities that were realized by rehabilitation robots in literature, in order to offer insights for developing a novel robot suitable for stroke rehabilitation. The control system of the lower limb rehabilitation robot in sitting position that was introduced in the previous work is discussed in detail to demonstrate the behavior of the robot while training a subject. The nonlinear impedance control law, based on active assistive control strategy, is able to define the response of the robot with more specifications while the passivity property and the robustness of the system is verified. A preliminary experiment is conducted on a healthy subject to show that the robot is able to perform active assistive exercises with various training activities and assist the subject to complete the training with desired level of assistance.

  13. Efficient sampling over rough energy landscapes with high barriers: A combination of metadynamics with integrated tempering sampling.

    PubMed

    Yang, Y Isaac; Zhang, Jun; Che, Xing; Yang, Lijiang; Gao, Yi Qin

    2016-03-07

    In order to efficiently overcome high free energy barriers embedded in a complex energy landscape and calculate overall thermodynamics properties using molecular dynamics simulations, we developed and implemented a sampling strategy by combining the metadynamics with (selective) integrated tempering sampling (ITS/SITS) method. The dominant local minima on the potential energy surface (PES) are partially exalted by accumulating history-dependent potentials as in metadynamics, and the sampling over the entire PES is further enhanced by ITS/SITS. With this hybrid method, the simulated system can be rapidly driven across the dominant barrier along selected collective coordinates. Then, ITS/SITS ensures a fast convergence of the sampling over the entire PES and an efficient calculation of the overall thermodynamic properties of the simulation system. To test the accuracy and efficiency of this method, we first benchmarked this method in the calculation of ϕ - ψ distribution of alanine dipeptide in explicit solvent. We further applied it to examine the design of template molecules for aromatic meta-C-H activation in solutions and investigate solution conformations of the nonapeptide Bradykinin involving slow cis-trans isomerizations of three proline residues.

  14. Efficient sampling over rough energy landscapes with high barriers: A combination of metadynamics with integrated tempering sampling

    NASA Astrophysics Data System (ADS)

    Yang, Y. Isaac; Zhang, Jun; Che, Xing; Yang, Lijiang; Gao, Yi Qin

    2016-03-01

    In order to efficiently overcome high free energy barriers embedded in a complex energy landscape and calculate overall thermodynamics properties using molecular dynamics simulations, we developed and implemented a sampling strategy by combining the metadynamics with (selective) integrated tempering sampling (ITS/SITS) method. The dominant local minima on the potential energy surface (PES) are partially exalted by accumulating history-dependent potentials as in metadynamics, and the sampling over the entire PES is further enhanced by ITS/SITS. With this hybrid method, the simulated system can be rapidly driven across the dominant barrier along selected collective coordinates. Then, ITS/SITS ensures a fast convergence of the sampling over the entire PES and an efficient calculation of the overall thermodynamic properties of the simulation system. To test the accuracy and efficiency of this method, we first benchmarked this method in the calculation of ϕ - ψ distribution of alanine dipeptide in explicit solvent. We further applied it to examine the design of template molecules for aromatic meta-C—H activation in solutions and investigate solution conformations of the nonapeptide Bradykinin involving slow cis-trans isomerizations of three proline residues.

  15. Efficient sampling over rough energy landscapes with high barriers: A combination of metadynamics with integrated tempering sampling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Y. Isaac; Zhang, Jun; Che, Xing

    2016-03-07

    In order to efficiently overcome high free energy barriers embedded in a complex energy landscape and calculate overall thermodynamics properties using molecular dynamics simulations, we developed and implemented a sampling strategy by combining the metadynamics with (selective) integrated tempering sampling (ITS/SITS) method. The dominant local minima on the potential energy surface (PES) are partially exalted by accumulating history-dependent potentials as in metadynamics, and the sampling over the entire PES is further enhanced by ITS/SITS. With this hybrid method, the simulated system can be rapidly driven across the dominant barrier along selected collective coordinates. Then, ITS/SITS ensures a fast convergence ofmore » the sampling over the entire PES and an efficient calculation of the overall thermodynamic properties of the simulation system. To test the accuracy and efficiency of this method, we first benchmarked this method in the calculation of ϕ − ψ distribution of alanine dipeptide in explicit solvent. We further applied it to examine the design of template molecules for aromatic meta-C—H activation in solutions and investigate solution conformations of the nonapeptide Bradykinin involving slow cis-trans isomerizations of three proline residues.« less

  16. Longitudinal Relationship Between Sitting Time on a Working Day and Vitality, Work Performance, Presenteeism, and Sickness Absence.

    PubMed

    Hendriksen, Ingrid J M; Bernaards, Claire M; Steijn, Wouter M P; Hildebrandt, Vincent H

    2016-08-01

    The aim of this study was to explore the longitudinal relationship between sitting time on a working day and vitality, work performance, presenteeism, and sickness absence. At the start and end of a five-month intervention program at the workplace, as well as 10 months after the intervention, sitting time and work-related outcomes were measured using a standardized self-administered questionnaire and company records. Generalized linear mixed models were used to estimate the longitudinal relationship between sitting time and work-related outcomes, and possible interaction effects over time. A significant and sustainable decrease in sitting time on a working day was observed. Sitting less was significantly related to higher vitality scores, but this effect was marginal (b = -0.0006, P = 0.000). Our finding of significant though marginal associations between sitting time and important work-related outcomes justifies further research.

  17. Usage of Sit-Stand Workstations and Associations Between Work and Nonwork Sitting Time: An Observational Study.

    PubMed

    Mazzotta, Michael A; Ferrar, Katia; Fraysse, Francois; Lewis, Lucy K; McEvoy, Maureen

    2018-05-01

    No studies have objectively measured habitual usage of sit-stand workstations. Eighteen full-time office workers participated (47.9 ± 9.2 years, 61% female). Sitting time was objectively measured (activPAL, 24 h/7 days), and time at desk, desk position, and perceptions of desk use were self-reported. Participants sat for 39% of their daily workstation time, and changed workstation position twice daily. The most common reasons for standing included back pain (44%) and tiredness (22%). The majority of participants received no workstation occupational health (72%) or educational (61%) information. Workstation standing time had a significant moderate correlation with total daily standing time (P = 0.02). Office workers with sit-stand workstations rarely change desk position, and there is no relationship between the time spent sitting at the workstation, and total daily sitting time. Education about the workstations was limited.

  18. Effects of deep breathing on internal oblique and multifidus muscle activity in three sitting postures

    PubMed Central

    Ko, Min-Joo; Jung, Eun-Joo; Kim, Moon-Hwan; Oh, Jae-Seop

    2018-01-01

    [Purpose] This study was to investigate differences in the level of activity of the external oblique (EO), internal oblique (IO), and multifidus (MF) muscles with deep breathing in three sitting postures. [Subjects and Methods] Sixteen healthy women were recruited. The muscle activity (EO, IO, MF) of all subjects was measured in three sitting postures (slumped, thoracic upright, and lumbo-pelvic upright sitting postures) using surface electromyography. The activity of the same muscles was then remeasured in the three sitting postures during deep breathing. [Results] Deep breathing significantly increased activity in the EO, IO, and MF compared with normal breathing. Comparing postures, the activity of the MF and IO muscles was highest in the lumbo-pelvic upright sitting posture. [Conclusion] An lumbo-pelvic upright sitting posture with deep breathing could increase IO and MF muscle activity, thus improving lumbo-pelvic region stability. PMID:29706695

  19. A Reconfigurable Real-Time Compressive-Sampling Camera for Biological Applications

    PubMed Central

    Fu, Bo; Pitter, Mark C.; Russell, Noah A.

    2011-01-01

    Many applications in biology, such as long-term functional imaging of neural and cardiac systems, require continuous high-speed imaging. This is typically not possible, however, using commercially available systems. The frame rate and the recording time of high-speed cameras are limited by the digitization rate and the capacity of on-camera memory. Further restrictions are often imposed by the limited bandwidth of the data link to the host computer. Even if the system bandwidth is not a limiting factor, continuous high-speed acquisition results in very large volumes of data that are difficult to handle, particularly when real-time analysis is required. In response to this issue many cameras allow a predetermined, rectangular region of interest (ROI) to be sampled, however this approach lacks flexibility and is blind to the image region outside of the ROI. We have addressed this problem by building a camera system using a randomly-addressable CMOS sensor. The camera has a low bandwidth, but is able to capture continuous high-speed images of an arbitrarily defined ROI, using most of the available bandwidth, while simultaneously acquiring low-speed, full frame images using the remaining bandwidth. In addition, the camera is able to use the full-frame information to recalculate the positions of targets and update the high-speed ROIs without interrupting acquisition. In this way the camera is capable of imaging moving targets at high-speed while simultaneously imaging the whole frame at a lower speed. We have used this camera system to monitor the heartbeat and blood cell flow of a water flea (Daphnia) at frame rates in excess of 1500 fps. PMID:22028852

  20. Method used to test the imaging consistency of binocular camera's left-right optical system

    NASA Astrophysics Data System (ADS)

    Liu, Meiying; Wang, Hu; Liu, Jie; Xue, Yaoke; Yang, Shaodong; Zhao, Hui

    2016-09-01

    To binocular camera, the consistency of optical parameters of the left and the right optical system is an important factor that will influence the overall imaging consistency. In conventional testing procedure of optical system, there lacks specifications suitable for evaluating imaging consistency. In this paper, considering the special requirements of binocular optical imaging system, a method used to measure the imaging consistency of binocular camera is presented. Based on this method, a measurement system which is composed of an integrating sphere, a rotary table and a CMOS camera has been established. First, let the left and the right optical system capture images in normal exposure time under the same condition. Second, a contour image is obtained based on the multiple threshold segmentation result and the boundary is determined using the slope of contour lines near the pseudo-contour line. Third, the constraint of gray level based on the corresponding coordinates of left-right images is established and the imaging consistency could be evaluated through standard deviation σ of the imaging grayscale difference D (x, y) between the left and right optical system. The experiments demonstrate that the method is suitable for carrying out the imaging consistency testing for binocular camera. When the standard deviation 3σ distribution of imaging gray difference D (x, y) between the left and right optical system of the binocular camera does not exceed 5%, it is believed that the design requirements have been achieved. This method could be used effectively and paves the way for the imaging consistency testing of the binocular camera.

  1. Sagittal lumbar and pelvic alignment in the standing and sitting positions.

    PubMed

    Endo, Kenji; Suzuki, Hidekazu; Nishimura, Hirosuke; Tanaka, Hidetoshi; Shishido, Takaaki; Yamamoto, Kengo

    2012-11-01

    The sitting position has become the most common posture in today's workplace. In relation to this position, kinematic analysis of the lumbar spine is helpful in understanding the causes of low back pain and its prevention. In this study, we investigated the relationship between sagittal lumbar alignment and pelvic alignment in the standing and sitting positions for 50 healthy adults. Lumbar lordotic angle (LLA), sacral slope (SS), pelvic tilt (PT), and pelvic incidence (PI) were measured on lateral lumbar spine standing and sitting radiographs. Regarding changes from the standing to sitting positions, average LLA, SS, and PT were -16.6° (-49.8 %), -18.7° (-50.3 %), and 18.3° (284.8 %), respectively (P < 0.01). In the sitting position, lumbar lordosis was reduced and pelvic rotation became posterior. This study showed that LLA decreased by approximately 50 % and PT increased by approximately 25 % in the sitting position compared with the standing position. No significant gender differences were observed for LLA, SS, and PT in the standing position. In the sitting position, however, LLA and SS were markedly larger for women.

  2. Improving Cardiometabolic Health with Diet, Physical Activity, and Breaking Up Sitting: What about Sleep?

    PubMed Central

    Vincent, Grace E.; Jay, Sarah M.; Sargent, Charli; Vandelanotte, Corneel; Ridgers, Nicola D.; Ferguson, Sally A.

    2017-01-01

    Cardiometabolic disease poses a serious health and economic burden worldwide and its prevalence is predicted to increase. Prolonged sitting, lack of physical activity, poor diet, and short sleep duration are ubiquitous behaviors in modern society, and all are independent risk factors in the development of cardiometabolic disease. Existing evidence demonstrates that breaking up prolonged periods of sitting is beneficial for cardiometabolic health, however, studies have not controlled for prior sleep duration. This article examines how prolonged sitting and short sleep duration independently contribute to cardiometabolic risk, and how breaking up sitting and obtaining adequate sleep may reduce this risk. We suggest that as prolonged sitting and short sleep duration influence the same cardiometabolic parameters, there is potential for short sleep to attenuate the positive impact of breaking up prolonged sitting with physical activity. Likewise, breaking up prolonged sitting and obtaining adequate sleep together could improve predictors of cardiometabolic disease, i.e., the combined effect may be stronger than either alone. To explore these perspectives, we propose a research agenda to investigate the relationship between breaking up prolonged sitting with physical activity and short sleep duration. This will provide an evidence-base for informing the design of interventions to reduce the burden of cardiometabolic disease on communities worldwide. PMID:29167645

  3. Neutral lumbar spine sitting posture in pain-free subjects.

    PubMed

    O'Sullivan, Kieran; O'Dea, Patrick; Dankaerts, Wim; O'Sullivan, Peter; Clifford, Amanda; O'Sullivan, Leonard

    2010-12-01

    Sitting is a common aggravating factor in low back pain (LBP), and re-education of sitting posture is a common aspect of LBP management. However, there is debate regarding what is an optimal sitting posture. This pilot study had 2 aims; to investigate whether pain-free subjects can be reliably positioned in a neutral sitting posture (slight lumbar lordosis and relaxed thorax); and to compare perceptions of neutral sitting posture to habitual sitting posture (HSP). The lower lumbar spine HSP of seventeen pain-free subjects was initially recorded. Subjects then assumed their own subjectively perceived ideal posture (SPIP). Finally, 2 testers independently positioned the subjects into a tester perceived neutral posture (TPNP). The inter-tester reliability of positioning in TPNP was very good (intraclass correlation coefficient (ICC) = 0.91, mean difference = 3% of range of motion). A repeated measures ANOVA revealed that HSP was significantly more flexed than both SPIP and TPNP (p <0.05). There was no significant difference between SPIP and TPNP (p > 0.05). HSP was more kyphotic than all other postures. This study suggests that pain-free subjects can be reliably positioned in a neutral lumbar sitting posture. Further investigation into the role of neutral sitting posture in LBP subjects is warranted. Copyright © 2010 Elsevier Ltd. All rights reserved.

  4. Relationship between postural alignment in sitting by photogrammetry and seated postural control in post-stroke subjects.

    PubMed

    Iyengar, Y R; Vijayakumar, K; Abraham, J M; Misri, Z K; Suresh, B V; Unnikrishnan, B

    2014-01-01

    This study was executed to find out correlation between postural alignment in sitting measured through photogrammetry and postural control in sitting following stroke. A cross-sectional study with convenient sampling consisting of 45 subjects with acute and sub-acute stroke. Postural alignment in sitting was measured through photogrammetry and relevant angles were obtained through software MB Ruler (version 5.0). Seated postural control was measured through Function in Sitting Test (FIST). Correlation was obtained using Spearman's Rank Correlation co-efficient in SPSS software (version 17.0). Moderate positive correlation (r = 0.385; p < 0.01) was found between angle of lordosis and angle between acromion, lateral epicondyle and point between radius and ulna. Strong negative correlation (r = -0.435; p < 0.01) was found between cranio-vertebral angle and kyphosis. FIST showed moderate positive correlation (r = 0.3446; p < 0.05) with cranio-vertebral angle and strong positive correlation (r = 0.4336; p < 0.01) with Brunnstrom's stage of recovery in upper extremity. Degree of forward head posture in sitting correlates directly with seated postural control and inversely with degree of kyphosis in sitting post-stroke. Postural control in sitting post-stroke is directly related with Brunnstrom's stage of recovery in affected upper extremity in sitting.

  5. Simple assessment of olfaction in patients with chronic rhinosinusitis.

    PubMed

    Kim, Byung Guk; Oh, Jeong-Hoon; Choi, Ha Na; Park, So Young

    2015-03-01

    The brief-smell identification test (B-SIT) can substitute for the butanol threshold test (BTT) in screening of anosmia and postoperative assessment of olfactory outcomes in patients with chronic rhinosinusitis (CRS). A time-effective test battery composed of B-SIT and the visual analog scale (VAS) can be implemented for simple olfactory assessment in any otolaryngology clinic. Anosmia is a distinct clinical entity requiring special attention. Unpredictable olfactory outcomes after surgery make preoperative assessment more important. We compared the results of the BTT, B-SIT, and VAS to investigate whether B-SIT or VAS can substitute for BTT in screening of anosmia and postoperative follow-up. We collected data on 68 CRS patients who had bilateral CRS and underwent endoscopic sinus surgery. Olfactory performance was graded using the BTT: normosmia, hyposmia, or anosmia. VAS and B-SIT were also performed. All tests were repeated 6 months after surgery. Postoperative improvement was defined by an increase of the BTT score ≥ 2. The B-SIT and VAS scores of the anomics were significantly lower than those of the normosmics. B-SIT discriminated anosmia with high specificity. Within the improvement group, postoperative increase of B-SIT/VAS score showed significance. However, neither the B-SIT nor the VAS differentiated between no change and deterioration of olfaction.

  6. Measurement of reach envelopes with a four-camera Selective Spot Recognition (SELSPOT) system

    NASA Technical Reports Server (NTRS)

    Stramler, J. H., Jr.; Woolford, B. J.

    1983-01-01

    The basic Selective Spot Recognition (SELSPOT) system is essentially a system which uses infrared LEDs and a 'camera' with an infrared-sensitive photodetector, a focusing lens, and some A/D electronics to produce a digital output representing an X and Y coordinate for each LED for each camera. When the data are synthesized across all cameras with appropriate calibrations, an XYZ set of coordinates is obtained for each LED at a given point in time. Attention is given to the operating modes, a system checkout, and reach envelopes and software. The Video Recording Adapter (VRA) represents the main addition to the basic SELSPOT system. The VRA contains a microprocessor and other electronics which permit user selection of several options and some interaction with the system.

  7. A goggle navigation system for cancer resection surgery

    NASA Astrophysics Data System (ADS)

    Xu, Junbin; Shao, Pengfei; Yue, Ting; Zhang, Shiwu; Ding, Houzhu; Wang, Jinkun; Xu, Ronald

    2014-02-01

    We describe a portable fluorescence goggle navigation system for cancer margin assessment during oncologic surgeries. The system consists of a computer, a head mount display (HMD) device, a near infrared (NIR) CCD camera, a miniature CMOS camera, and a 780 nm laser diode excitation light source. The fluorescence and the background images of the surgical scene are acquired by the CCD camera and the CMOS camera respectively, co-registered, and displayed on the HMD device in real-time. The spatial resolution and the co-registration deviation of the goggle navigation system are evaluated quantitatively. The technical feasibility of the proposed goggle system is tested in an ex vivo tumor model. Our experiments demonstrate the feasibility of using a goggle navigation system for intraoperative margin detection and surgical guidance.

  8. Improving Hip-Worn Accelerometer Estimates of Sitting Using Machine Learning Methods.

    PubMed

    Kerr, Jacqueline; Carlson, Jordan; Godbole, Suneeta; Cadmus-Bertram, Lisa; Bellettiere, John; Hartman, Sheri

    2018-02-13

    To improve estimates of sitting time from hip worn accelerometers used in large cohort studies by employing machine learning methods developed on free living activPAL data. Thirty breast cancer survivors concurrently wore a hip worn accelerometer and a thigh worn activPAL for 7 days. A random forest classifier, trained on the activPAL data, was employed to detect sitting, standing and sit-stand transitions in 5 second windows in the hip worn accelerometer. The classifier estimates were compared to the standard accelerometer cut point and significant differences across different bout lengths were investigated using mixed effect models. Overall, the algorithm predicted the postures with moderate accuracy (stepping 77%, standing 63%, sitting 67%, sit to stand 52% and stand to sit 51%). Daily level analyses indicated that errors in transition estimates were only occurring during sitting bouts of 2 minutes or less. The standard cut point was significantly different from the activPAL across all bout lengths, overestimating short bouts and underestimating long bouts. This is among the first algorithms for sitting and standing for hip worn accelerometer data to be trained from entirely free living activPAL data. The new algorithm detected prolonged sitting which has been shown to be most detrimental to health. Further validation and training in larger cohorts is warranted.This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

  9. 'The End of Sitting': An Empirical Study on Working in an Office of the Future.

    PubMed

    Withagen, Rob; Caljouw, Simone R

    2016-07-01

    Inspired by recent findings that prolonged sitting has detrimental health effects, Rietveld Architecture Art Affordances (RAAAF) and visual artist Barbara Visser designed a working environment without chairs and desks. This environment, which they called The End of Sitting, is a sculpture whose surfaces afford working in several non-sitting postures (e.g. lying, standing, leaning). In the present study, it was tested how people use and experience The End of Sitting. Eighteen participants were to work in this environment and in a conventional office with chairs and desks, and the participants' activities, postures, and locations in each working environment were monitored. In addition, participants' experiences with working in the offices were measured with a questionnaire. It was found that 83 % of participants worked in more than one non-sitting posture in The End of Sitting. All these participants also changed location in this working environment. On the other hand, in the conventional office all but one participant sat on a chair at a desk during the entire work session. On average, participants reported that The End of Sitting supported their well-being more than the conventional office. Participants also felt more energetic after working in The End of Sitting. No differences between the working environments were found in reported concentration levels and satisfaction with the created product. The End of Sitting is a potential alternative working environment that deserves to be examined in more detail.

  10. Evaluation of ergonomic and education interventions to reduce occupational sitting in office-based university workers: study protocol for a randomized controlled trial.

    PubMed

    Radas, Antonia; Mackey, Martin; Leaver, Andrew; Bouvier, Anna-Louise; Chau, Josephine Y; Shirley, Debra; Bauman, Adrian

    2013-10-12

    Prolonged sitting is a specific occupational hazard in office workers. There is growing evidence that prolonged sitting is detrimental to metabolic health. The aim of this study is to determine whether providing office workers with education along with adjustable sit-stand workstations leads to reduction in sitting behavior. A randomized control trial (RCT) with three groups (one control group and two intervention groups) will be conducted in an office workplace setting. The education intervention group will receive an education package that encourages reduction in sitting behaviors. The sit-stand desk intervention group will receive the same education package along with an adjustable sit-stand desk. Participants will be included in the study if they are currently employed in a full-time academic or administrative role that involves greater than 15 hours per week or greater than 4 hours per day computer-based work. Baseline data will include participant's age, gender, weight, height, smoking habit, employment position, level of education, and baseline self-reported leisure time physical activity. The primary outcome is the average daily sedentary time during work hours, measured by an accelerometer. Participant recruitment commenced in March 2013 and will be completed by December 2013. This study will determine whether providing office workers with an adjustable sit-stand desk and individually targeted education, or education alone, is more effective in decreasing sitting behaviors than no intervention. Australian New Zealand Clinical Trials Registry: ACTRN12613000366752.

  11. The Short-Term Effects of Lying, Sitting and Standing on Energy Expenditure in Women

    PubMed Central

    POPP, COLLIN J.; BRIDGES, WILLIAM C.; JESCH, ELLIOT D.

    2018-01-01

    The deleterious health effects of too much sitting have been associated with an increased risk for overweight and obesity. Replacing sitting with standing is the proposed intervention to increase daily energy expenditure (EE). The purpose of this study was to determine the short-term effects of lying, sitting, and standing postures on EE, and determine the magnitude of the effect each posture has on EE using indirect calorimetry (IC). Twenty-eight healthy females performed three separate positions (lying, sitting, standing) in random order. Inspired and expired gases were collected for 45-minutes (15 minutes for each position) using breath-by-breath indirect calorimetry. Oxygen consumption (VO2) and carbon dioxide production (VCO2) were measured to estimate EE. Statistical analyses used repeat measures ANOVA to analyze all variables and post hoc t-tests. Based on the ANOVA the individual, time period and order term did not result in a statistically significant difference. Lying EE and sitting EE were not different from each other (P = 0.56). However, standing EE (kcal/min) was 9.0 % greater than lying EE (kcal/min) (P = 0.003), and 7.1% greater than sitting EE (kcal/min) (P = 0.02). The energetic cost of standing was higher compared to lying and sitting. While this is statistically significant, the magnitude of the effect of standing when compared to sitting was small (Cohen’s d = 0.31). Short-term standing does not offer an energetic advantage when compared to sitting.

  12. Reducing occupational sitting: Workers' perspectives on participation in a multi-component intervention.

    PubMed

    Hadgraft, Nyssa T; Willenberg, Lisa; LaMontagne, Anthony D; Malkoski, Keti; Dunstan, David W; Healy, Genevieve N; Moodie, Marj; Eakin, Elizabeth G; Owen, Neville; Lawler, Sheleigh P

    2017-05-30

    Office workers spend much of their time sitting, which is now understood to be a risk factor for several chronic diseases. This qualitative study examined participants' perspectives following their involvement in a cluster randomised controlled trial of a multi-component intervention targeting prolonged workplace sitting (Stand Up Victoria). The intervention incorporated a sit-stand workstation, individual health coaching and organisational support strategies. The aim of the study was to explore the acceptability of the intervention, barriers and facilitators to reducing workplace sitting, and perceived effects of the intervention on workplace culture, productivity and health-related outcomes. Semi-structured interviews (n = 21 participants) and two focus groups (n = 7) were conducted with intervention participants at the conclusion of the 12 month trial and thematic analysis was used to analyse the data. Questions covered intervention acceptability, overall impact, barriers and facilitators to reducing workplace sitting, and perceived impact on productivity and workplace culture. Overall, participants had positive intervention experiences, perceiving that reductions in workplace sitting were associated with improved health and well-being with limited negative impact on work performance. While sit-stand workstations appeared to be the primary drivers of change, workstation design and limited suitability of standing for some job tasks and situations were perceived as barriers to their use. Social support from team leaders and other participants was perceived to facilitate behavioural changes and a shift in norms towards increased acceptance of standing in the workplace. Multi-component interventions to reduce workplace sitting, incorporating sit-stand workstations, are acceptable and feasible; however, supportive social and environmental conditions are required to support participant engagement. Best practice approaches to reduce workplace sitting should address the multiple levels of influence on behaviour, including factors that may act as barriers to behavioural change.

  13. Validity of a multi-context sitting questionnaire across demographically diverse population groups: AusDiab3.

    PubMed

    Clark, Bronwyn K; Lynch, Brigid M; Winkler, Elisabeth Ah; Gardiner, Paul A; Healy, Genevieve N; Dunstan, David W; Owen, Neville

    2015-12-04

    Sitting time questionnaires have largely been validated in small convenience samples. The validity of this multi-context sitting questionnaire against an accurate measure of sitting time is reported in a large demographically diverse sample allowing assessment of validity in varied demographic subgroups. A subgroup of participants of the third wave of the Australian Diabetes, Obesity, and Lifestyle (AusDiab3) study wore activPAL3™ monitors (7 days, 24 hours/day protocol) and reported their sitting time for work, travel, television viewing, leisure computer use and "other" purposes, on weekdays and weekend days (n = 700, age 36-89 years, 45% men). Correlations (Pearson's r; Spearman's ρ) of the self-report measures (the composite total, contextual measures and items) with monitor-assessed sitting time were assessed in the whole sample and separately in socio-demographic subgroups. Agreement was assessed using Bland-Altman plots. The composite total had a correlation with monitor-assessed sitting time of r = 0.46 (95% confidence interval [CI]: 0.40, 0.52); this correlation did not vary significantly between demographic subgroups (all >0.4). The contextual measure most strongly correlated with monitor-assessed sitting time was work (ρ = 0.25, 95 % CI: 0.17, 0.31), followed by television viewing (ρ = 0.16, 95 % CI: 0.09, 0.24). Agreement of the composite total with monitored sitting time was poor, with a positive bias (B = 0.53, SE 0.04, p < 0.001) and wide limits of agreement (±4.32 h). This multi-context questionnaire provides a total sitting time measure that ranks participants well for the purposes of assessing health associations but has limited accuracy relative to activPAL-assessed sitting time. Findings did not differ in demographic subgroups.

  14. Patient knowledge, perceptions, expectations and satisfaction on allergen-specific immunotherapy: a survey.

    PubMed

    Baiardini, Ilaria; Puggioni, Francesca; Menoni, Stefania; Boot, Johan Diderik; Diamant, Zuzana; Braido, Fulvio; Canonica, Giorgio Walter

    2013-03-01

    Assessing patient's perspective provides useful information enabling a customized approach which has been advocated by current guidelines. In this multicentre cross-sectional study we evaluated personal viewpoints on allergen-specific immunotherapy (SIT) in patients treated with subcutaneous (SCIT) or sublingual (SLIT) immunotherapy. A survey of 28 questions assessing patient's knowledge, perceptions, expectations and satisfaction was developed by an expert panel and was applied by physicians from allergology centres in patients with respiratory allergy treated with SIT. Treating physicians independently reported their satisfaction level regarding SIT for each patient. Fully completed surveys from 434 patients (55.3% male; 66.7% poly-sensitized, 74% SLIT) were analysed. Mean duration of SIT was 2.5 years with different allergens. Most patients acquired their SIT knowledge from their physician (95%) and consequently, their physicians' opinion in their choice to start with SIT was important. Most patients perceived SIT to be safe and easy to integrate into their daily routine. The main motivations for SIT were its supposed potential to alter the course of the disease (45.7%), less need of (28.2%), or dissatisfaction with current pharmacotherapy (19.3%). Both patients' and physicians' satisfaction was high (VAS-scores 74/100 and 78/100, respectively) and showed a significant correlation (SCIT: r=0.612; SLIT: r=0.608). No major difference was found in patients' answers based on the level of education. In this real life study evaluating different aspects of patient's perspective on SIT, the majority of patients had an adequate level of knowledge, perceptions, expectations and satisfaction about SIT, which corresponded well with the physician's perceptions and satisfaction. Our data warrant the use of patient's perspectives on chronic SIT treatment. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Project Energise: Using participatory approaches and real time computer prompts to reduce occupational sitting and increase work time physical activity in office workers.

    PubMed

    Gilson, Nicholas D; Ng, Norman; Pavey, Toby G; Ryde, Gemma C; Straker, Leon; Brown, Wendy J

    2016-11-01

    This efficacy study assessed the added impact real time computer prompts had on a participatory approach to reduce occupational sedentary exposure and increase physical activity. Quasi-experimental. 57 Australian office workers (mean [SD]; age=47 [11] years; BMI=28 [5]kg/m 2 ; 46 men) generated a menu of 20 occupational 'sit less and move more' strategies through participatory workshops, and were then tasked with implementing strategies for five months (July-November 2014). During implementation, a sub-sample of workers (n=24) used a chair sensor/software package (Sitting Pad) that gave real time prompts to interrupt desk sitting. Baseline and intervention sedentary behaviour and physical activity (GENEActiv accelerometer; mean work time percentages), and minutes spent sitting at desks (Sitting Pad; mean total time and longest bout) were compared between non-prompt and prompt workers using a two-way ANOVA. Workers spent close to three quarters of their work time sedentary, mostly sitting at desks (mean [SD]; total desk sitting time=371 [71]min/day; longest bout spent desk sitting=104 [43]min/day). Intervention effects were four times greater in workers who used real time computer prompts (8% decrease in work time sedentary behaviour and increase in light intensity physical activity; p<0.01). Respective mean differences between baseline and intervention total time spent sitting at desks, and the longest bout spent desk sitting, were 23 and 32min/day lower in prompt than in non-prompt workers (p<0.01). In this sample of office workers, real time computer prompts facilitated the impact of a participatory approach on reductions in occupational sedentary exposure, and increases in physical activity. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  16. RAAAF’s office landscape The End of Sitting: Energy expenditure and temporary comfort when working in non-sitting postures

    PubMed Central

    de Vries, Rutger; Withagen, Rob

    2017-01-01

    Abstract An earlier study suggested that the activity-inviting office landscape called “The End of Sitting”, designed by Rietveld Architecture Art Affordances (RAAAF), should be considered as an alternative working environment to prevent sedentary behavior. The End of Sitting lacks chairs and tables but consists instead of a myriad of sloped surfaces at different heights that afford workers to stand, lean or recline at different locations. In this study, we assessed the impact of four of its workspaces on physical intensity, temporary comfort and productivity of office work and compared the outcomes with sitting and standing behind a desk. Twenty-four participants worked for 10 minutes in each of the six test conditions. Energy expenditure, measured by indirect calorimetry, and heart rate were recorded. Questionnaires were used to assess the perceived comfort. The number of words found in the word search test was counted as a measure of productivity. The majority of The End of Sitting workspaces led to a significant increase in energy expenditure compared with sitting behind a desk (ps < .05). Average MET values ranged from 1.40 to 1.58 which is a modest rise in energy expenditure compared to sitting (1.32 METs) and not significantly different from standing (1.47 METs). The scores on the general comfort scale indicated that some workspaces were less comfortable than sitting (ps < .05), but the vast majority of participants reported that at least one of The End of Sitting workspaces was equally or more comfortable than sitting. No differences in productivity between the test conditions were found. Further long-term studies are required to assess the behavioral adaptations, productivity and the level of comfort when using The End of Sitting as a permanent office. PMID:29125854

  17. Effect of a novel two-desk sit-to-stand workplace (ACTIVE OFFICE) on sitting time, performance and physiological parameters: protocol for a randomized control trial.

    PubMed

    Schwartz, Bernhard; Kapellusch, Jay M; Schrempf, Andreas; Probst, Kathrin; Haller, Michael; Baca, Arnold

    2016-07-15

    Prolonged sitting is ubiquitous in modern society and linked to several diseases. Height-adjustable desks are being used to decrease worksite based sitting time (ST). Single-desk sit-to-stand workplaces exhibit small ST reduction potential and short-term loss in performance. The aim of this paper is to report the study design and methodology of an ACTIVE OFFICE trial. The study was a 1-year three-arm, randomized controlled trial in 18 healthy Austrian office workers. Allocation was done via a regional health insurance, with data collection during Jan 2014 - March 2015. Participants were allocated to either an intervention or control group. Intervention group subjects were provided with traditional or two-desk sit-to-stand workstations in either the first or the second half of the study, while control subjects did not experience any changes during the whole study duration. Sitting time and physical activity (IPAQ-long), cognitive performance (text editing task, Stroop-test, d2R test of attention), workload perception (NASA-TLX) and physiological parameters (salivary cortisol, heartrate variability and body weight) were measured pre- and post-intervention (23 weeks after baseline) for intervention and control periods. Postural changes and sitting/standing time (software logger) were recorded at the workplace for the whole intervention period. This study evaluates the effects of a novel two-desk sit-to-stand workplace on sitting time, physical parameters and work performance of healthy office based workers. If the intervention proves effective, it has a great potential to be implemented in regular workplaces to reduce diseases related to prolonged sitting. ClinicalTrials.gov Identifier: NCT02825303 , July 2016 (retrospectively registered).

  18. Self-reported sitting time and physical activity: interactive associations with mental well-being and productivity in office employees.

    PubMed

    Puig-Ribera, Anna; Martínez-Lemos, Iván; Giné-Garriga, Maria; González-Suárez, Ángel Manuel; Bort-Roig, Judit; Fortuño, Jesús; Muñoz-Ortiz, Laura; McKenna, Jim; Gilson, Nicholas D

    2015-01-31

    Little is known about how sitting time, alone or in combination with markers of physical activity (PA), influences mental well-being and work productivity. Given the need to develop workplace PA interventions that target employees' health related efficiency outcomes; this study examined the associations between self-reported sitting time, PA, mental well-being and work productivity in office employees. Descriptive cross-sectional study. Spanish university office employees (n = 557) completed a survey measuring socio-demographics, total and domain specific (work and travel) self-reported sitting time, PA (International Physical Activity Questionnaire short version), mental well-being (Warwick-Edinburg Mental Well-Being Scale) and work productivity (Work Limitations Questionnaire). Multivariate linear regression analyses determined associations between the main variables adjusted for gender, age, body mass index and occupation. PA levels (low, moderate and high) were introduced into the model to examine interactive associations. Higher volumes of PA were related to higher mental well-being, work productivity and spending less time sitting at work, throughout the working day and travelling during the week, including the weekends (p < 0.05). Greater levels of sitting during weekends was associated with lower mental well-being (p < 0.05). Similarly, more sitting while travelling at weekends was linked to lower work productivity (p < 0.05). In highly active employees, higher sitting times on work days and occupational sitting were associated with decreased mental well-being (p < 0.05). Higher sitting times while travelling on weekend days was also linked to lower work productivity in the highly active (p < 0.05). No significant associations were observed in low active employees. Employees' PA levels exerts different influences on the associations between sitting time, mental well-being and work productivity. The specific associations and the broad sweep of evidence in the current study suggest that workplace PA strategies to improve the mental well-being and productivity of all employees should focus on reducing sitting time alongside efforts to increase PA.

  19. What are the working mechanisms of a web-based workplace sitting intervention targeting psychosocial factors and action planning?

    PubMed

    De Cocker, Katrien; De Bourdeaudhuij, Ilse; Cardon, Greet; Vandelanotte, Corneel

    2017-05-03

    Office workers demonstrate high levels of sitting on workdays. As sitting is positively associated with adverse health risks in adults, a theory-driven web-based computer-tailored intervention to influence workplace sitting, named 'Start to Stand,' was developed. The intervention was found to be effective in reducing self-reported workplace sitting among Flemish employees. The aim of this study was to investigate through which mechanisms the web-based computer-tailored intervention influenced self-reported workplace sitting. Employees (n = 155) participated in a clustered randomised controlled trial and reported socio-demographics (age, gender, education), work-related (hours at work, employment duration), health-related (weight and height, workplace sitting and physical activity) and psychosocial (knowledge, attitudes, self-efficacy, social support, intention regarding (changing) sitting behaviours) variables at baseline and 1-month follow-up. The product-of-coefficients test of MacKinnon based on multiple linear regression analyses was conducted to examine the mediating role of five psychosocial factors (knowledge, attitudes, self-efficacy, social support, intention). The influence of one self-regulation skill (action planning) in the association between the intervention and self-reported workplace sitting time was investigated via moderation analyses. The intervention had a positive influence on knowledge (p = 0.040), but none of the psychosocial variables did mediate the intervention effect on self-reported workplace sitting. Action planning was found to be a significant moderator (p < 0.001) as the decrease in self-reported workplace sitting only occurred in the group completing an action plan. Future interventions aimed at reducing employees' workplace sitting are suggested to focus on self-regulatory skills and promote action planning when using web-based computer-tailored advice. Clinicaltrials.gov NCT02672215 ; (Archived by WebCite at https://clinicaltrials.gov/ct2/show/NCT02672215 ).

  20. Genetic Diversity of Mycobacterium tuberculosis in Peru and Exploration of Phylogenetic Associations with Drug Resistance

    PubMed Central

    Sheen, Patricia; Couvin, David; Grandjean, Louis; Zimic, Mirko; Dominguez, Maria; Luna, Giannina; Gilman, Robert H.; Rastogi, Nalin; Moore, David A. J.

    2013-01-01

    Background There is limited available data on the strain diversity of M tuberculosis in Peru, though there may be interesting lessons to learn from a setting where multidrug resistant TB has emerged as a major problem despite an apparently well-functioning DOTS control programme. Methods Spoligotyping was undertaken on 794 strains of M tuberculosis collected between 1999 and 2005 from 553 community-based patients and 241 hospital-based HIV co-infected patients with pulmonary tuberculosis in Lima, Peru. Phylogenetic and epidemiologic analyses permitted identification of clusters and exploration of spoligotype associations with drug resistance. Results Mean patient age was 31.9 years, 63% were male and 30.4% were known to be HIV+. Rifampicin mono-resistance, isoniazid mono-resistance and multidrug resistance (MDR) were identified in 4.7%, 8.7% and 17.3% of strains respectively. Of 794 strains from 794 patients there were 149 different spoligotypes. Of these there were 27 strains (3.4%) with novel, unique orphan spoligotypes. 498 strains (62.7%) were clustered in the nine most common spoligotypes: 16.4% SIT 50 (clade H3), 12.3% SIT 53 (clade T1), 8.3% SIT 33 (LAM3), 7.4% SIT 42 (LAM9), 5.5% SIT 1 (Beijing), 3.9% SIT 47 (H1), 3.0% SIT 222 (clade unknown), 3.0% SIT1355 (LAM), and 2.8% SIT 92 (X3). Amongst HIV-negative community-based TB patients no associations were seen between drug resistance and specific spoligotypes; in contrast HIV-associated MDRTB, but not isoniazid or rifampicin mono-resistance, was associated with SIT42 and SIT53 strains. Conclusion Two spoligotypes were associated with MDR particularly amongst patients with HIV. The MDR-HIV association was significantly reduced after controlling for SIT42 and SIT53 status; residual confounding may explain the remaining apparent association. These data are suggestive of a prolonged, clonal, hospital-based outbreak of MDR disease amongst HIV patients but do not support a hypothesis of strain-specific propensity for the acquisition of resistance-conferring mutations. PMID:23826083

  1. Effect of alternating standing and sitting on blood pressure and pulse wave velocity during a simulated workday in adults with overweight/obesity.

    PubMed

    Barone Gibbs, Bethany; Kowalsky, Robert J; Perdomo, Sophy J; Taormina, John M; Balzer, Jeffrey R; Jakicic, John M

    2017-12-01

    Reducing prolonged sitting at work has been recommended by an expert panel, but whether intermittent standing improves vascular health is unclear. We aimed to test whether using a sit-stand desk could reduce blood pressure (BP) and pulse wave velocity (PWV) during a simulated workday. Overweight/obese adults with pre-to-Stage 1 hypertension completed a randomized crossover study with two simulated workday conditions: STAND-SIT (alternating standing and sitting condition every 30 min) and SIT (continuous sitting condition). Oscillometric BP was measured hourly. Carotid-femoral, carotid-radial, and carotid-ankle PWV were measured in the morning, mid-day, and late afternoon using tonometry. Participants [n = 25, 64% male, 84% white, mean (SD) age: 42 (12) years] had average resting SBP of 132 (9) mmHg and DBP of 83 (8) mmHg. In linear mixed models, STAND-SIT resulted in a significantly lower DBP (mean ± SE: -1.0 ± 0.4 mmHg, P = 0.020) and mean arterial pressure (MAP) (-1.0 ± 0.4 mmHg, P = 0.029) compared with SIT. SBP (-0.9 ± 0.7 mmHg, P = 0.176) was not different across conditions. Carotid-ankle PWV was significantly lower during the STAND-SIT vs. SIT condition (-0.27 ± 0.13 m/s, P = 0.047), whereas carotid-femoral PWV (-0.03 ± 0.13 m/s, P = 0.831) and carotid-radial PWV (-0.30 ± 0.18 m/s, P = 0.098) were not. Changes in MAP partially explained changes in PWV. Interrupting prolonged sitting during deskwork with intermittent standing was a sufficient stimulus to slightly, but statistically significantly, decrease DBP, MAP, and carotid-ankle PWV. Though the clinical significance of the observed effects is modest, regular use of a sit-stand desk may be a practical way to lower BP and PWV while performing deskwork.

  2. OpenCV and TYZX : video surveillance for tracking.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    He, Jim; Spencer, Andrew; Chu, Eric

    2008-08-01

    As part of the National Security Engineering Institute (NSEI) project, several sensors were developed in conjunction with an assessment algorithm. A camera system was developed in-house to track the locations of personnel within a secure room. In addition, a commercial, off-the-shelf (COTS) tracking system developed by TYZX was examined. TYZX is a Bay Area start-up that has developed its own tracking hardware and software which we use as COTS support for robust tracking. This report discusses the pros and cons of each camera system, how they work, a proposed data fusion method, and some visual results. Distributed, embedded image processingmore » solutions show the most promise in their ability to track multiple targets in complex environments and in real-time. Future work on the camera system may include three-dimensional volumetric tracking by using multiple simple cameras, Kalman or particle filtering, automated camera calibration and registration, and gesture or path recognition.« less

  3. Software for minimalistic data management in large camera trap studies

    PubMed Central

    Krishnappa, Yathin S.; Turner, Wendy C.

    2014-01-01

    The use of camera traps is now widespread and their importance in wildlife studies well understood. Camera trap studies can produce millions of photographs and there is a need for software to help manage photographs efficiently. In this paper, we describe a software system that was built to successfully manage a large behavioral camera trap study that produced more than a million photographs. We describe the software architecture and the design decisions that shaped the evolution of the program over the study’s three year period. The software system has the ability to automatically extract metadata from images, and add customized metadata to the images in a standardized format. The software system can be installed as a standalone application on popular operating systems. It is minimalistic, scalable and extendable so that it can be used by small teams or individual researchers for a broad variety of camera trap studies. PMID:25110471

  4. Impact of sit-stand desks at work on energy expenditure and sedentary time: protocol for a feasibility study.

    PubMed

    Mantzari, Eleni; Wijndaele, Katrien; Brage, Soren; Griffin, Simon J; Marteau, Theresa M

    2016-01-01

    Prolonged sitting, an independent risk factor for disease development and premature mortality, is increasing in prevalence in high- and middle-income countries, with no signs of abating. Adults in such countries spend the largest proportion of their day in sedentary behaviour, most of which is accumulated at work. One promising method for reducing workplace sitting is the use of sit-stand desks. However, key uncertainties remain about this intervention, related to the quality of existing studies and a lack of focus on key outcomes, including energy expenditure. We are planning a randomised controlled trial to assess the impact of sit-stand desks at work on energy expenditure and sitting time in the short and longer term. To reduce the uncertainties related to the design of this trial, we propose a preliminary study to assess the feasibility and acceptability of the recruitment, allocation, measurement, retention and intervention procedures. Five hundred office-based employees from two companies in Cambridge, UK, will complete a survey to assess their interest in participating in a trial on the use of sit-stand desks at work. The workspaces of 100 of those interested in participating will be assessed for sit-stand desk installation suitability, and 20 participants will be randomised to either the use of sit-stand desks at work for 3 months or a waiting list control group. Energy expenditure and sitting time, measured via Actiheart and activPAL monitors, respectively, as well as cardio-metabolic and anthropometric outcomes and other outcomes relating to health and work performance, will be assessed in 10 randomly selected participants. All participants will also be interviewed about their experience of using the desks and participating in the study. The findings are expected to inform the design of a trial assessing the impact of sit-stand desks at work on short and longer term workplace sitting, taking into account their impact on energy expenditure and the extent to which their use has compensation effects outside the workplace. The findings from such a trial are expected to inform discussions regarding the potential of sit-stand desks at work to alleviate the harm to cardio-metabolic health arising from prolonged sitting. ISRCTN44827407.

  5. Study of Mycobacterium tuberculosis Complex Genotypic Diversity in Malaysia Reveals a Predominance of Ancestral East-African-Indian Lineage with a Malaysia-Specific Signature

    PubMed Central

    Ismail, Fazli; Couvin, David; Farakhin, Izzah; Abdul Rahman, Zaidah; Rastogi, Nalin; Suraiya, Siti

    2014-01-01

    Background Tuberculosis (TB) still constitutes a major public health problem in Malaysia. The identification and genotyping based characterization of Mycobacterium tuberculosis complex (MTBC) isolates causing the disease is important to determine the effectiveness of the control and surveillance programs. Objectives This study intended a first assessment of spoligotyping-based MTBC genotypic diversity in Malaysia followed by a comparison of strains with those prevailing in neighboring countries by comparison with an international MTBC genotyping database. Methods Spoligotyping was performed on a total of 220 M. tuberculosis clinical isolates collected in Kelantan and Kuala Lumpur. The results were compared with the SITVIT2 international database of the Pasteur Institute of Guadeloupe. Results Spoligotyping revealed 77 different patterns: 22 corresponded to orphan patterns while 55 patterns containing 198 isolates were assigned a Spoligo International Type (SIT) designation in the database (the latter included 6 newly created SITs). The eight most common SITs grouped 141 isolates (5 to 56 strains per cluster) as follows: SIT1/Beijing, n = 56, 25.5%; SIT745/EAI1-SOM, n = 33, 15.0%; SIT591/EAI6-BGD1, n = 13, 5.9%; SIT256/EAI5, n = 12, 5.5%; SIT236/EAI5, n = 10, 4.6%; SIT19/EAI2-Manila, n = 9, 4.1%; SIT89/EAI2-Nonthaburi, n = 5, 2.3%; and SIT50/H3, n = 3, 1.4%. The association between city of isolation and lineages was statistically significant; Haarlem and T lineages being higher in Kuala Lumpur (p<0.01). However, no statistically significant differences were noted when comparing drug resistance vs. major lineages, nor between gender and clades. Conclusions The ancestral East-African-Indian (EAI) lineage was most predominant followed by the Beijing lineage. A comparison of strains with those prevailing in neighboring countries in South Asia, East Asia and South East Asia underlined the phylogeographical specificity of SIT745 for Malaysia, and its probable ongoing evolution with locally evolved strains sharing a specific signature characterized by absence of spacers 37, 38, and 40. Pending complementary genotyping confirmation, we propose that SIT745/EAI-SOM is tentatively reclassified as SIT745/EAI-MYS. PMID:25502956

  6. Criterion-Related Validity of Sit-and-Reach Tests for Estimating Hamstring and Lumbar Extensibility: a Meta-Analysis

    PubMed Central

    Mayorga-Vega, Daniel; Merino-Marban, Rafael; Viciana, Jesús

    2014-01-01

    The main purpose of the present meta-analysis was to examine the scientific literature on the criterion-related validity of sit-and-reach tests for estimating hamstring and lumbar extensibility. For this purpose relevant studies were searched from seven electronic databases dated up through December 2012. Primary outcomes of criterion-related validity were Pearson´s zero-order correlation coefficients (r) between sit-and-reach tests and hamstrings and/or lumbar extensibility criterion measures. Then, from the included studies, the Hunter- Schmidt´s psychometric meta-analysis approach was conducted to estimate population criterion- related validity of sit-and-reach tests. Firstly, the corrected correlation mean (rp), unaffected by statistical artefacts (i.e., sampling error and measurement error), was calculated separately for each sit-and-reach test. Subsequently, the three potential moderator variables (sex of participants, age of participants, and level of hamstring extensibility) were examined by a partially hierarchical analysis. Of the 34 studies included in the present meta-analysis, 99 correlations values across eight sit-and-reach tests and 51 across seven sit-and-reach tests were retrieved for hamstring and lumbar extensibility, respectively. The overall results showed that all sit-and-reach tests had a moderate mean criterion-related validity for estimating hamstring extensibility (rp = 0.46-0.67), but they had a low mean for estimating lumbar extensibility (rp = 0. 16-0.35). Generally, females, adults and participants with high levels of hamstring extensibility tended to have greater mean values of criterion-related validity for estimating hamstring extensibility. When the use of angular tests is limited such as in a school setting or in large scale studies, scientists and practitioners could use the sit-and-reach tests as a useful alternative for hamstring extensibility estimation, but not for estimating lumbar extensibility. Key Points Overall sit-and-reach tests have a moderate mean criterion-related validity for estimating hamstring extensibility, but they have a low mean validity for estimating lumbar extensibility. Among all the sit-and-reach test protocols, the Classic sit-and-reach test seems to be the best option to estimate hamstring extensibility. End scores (e.g., the Classic sit-and-reach test) are a better indicator of hamstring extensibility than the modifications that incorporate fingers-to-box distance (e.g., the Modified sit-and-reach test). When angular tests such as straight leg raise or knee extension tests cannot be used, sit-and-reach tests seem to be a useful field test alternative to estimate hamstring extensibility, but not to estimate lumbar extensibility. PMID:24570599

  7. Evaluating the effectiveness of organisational-level strategies with or without an activity tracker to reduce office workers' sitting time: a cluster-randomised trial.

    PubMed

    Brakenridge, C L; Fjeldsoe, B S; Young, D C; Winkler, E A H; Dunstan, D W; Straker, L M; Healy, G N

    2016-11-04

    Office workers engage in high levels of sitting time. Effective, context-specific, and scalable strategies are needed to support widespread sitting reduction. This study aimed to evaluate organisational-support strategies alone or in combination with an activity tracker to reduce sitting in office workers. From one organisation, 153 desk-based office workers were cluster-randomised (by team) to organisational support only (e.g., manager support, emails; 'Group ORG', 9 teams, 87 participants), or organisational support plus LUMOback activity tracker ('Group ORG + Tracker', 9 teams, 66 participants). The waist-worn tracker provided real-time feedback and prompts on sitting and posture. ActivPAL3 monitors were used to ascertain primary outcomes (sitting time during work- and overall hours) and other activity outcomes: prolonged sitting time (≥30 min bouts), time between sitting bouts, standing time, stepping time, and number of steps. Health and work outcomes were assessed by questionnaire. Changes within each group (three- and 12 months) and differences between groups were analysed by linear mixed models. Missing data were multiply imputed. At baseline, participants (46 % women, 23-58 years) spent (mean ± SD) 74.3 ± 9.7 % of their workday sitting, 17.5 ± 8.3 % standing and 8.1 ± 2.7 % stepping. Significant (p < 0.05) reductions in sitting time (both work and overall) were observed within both groups, but only at 12 months. For secondary activity outcomes, Group ORG significantly improved in work prolonged sitting, time between sitting bouts and standing time, and overall prolonged sitting time (12 months), and in overall standing time (three- and 12 months); while Group ORG + Tracker, significantly improved in work prolonged sitting, standing, stepping and overall standing time (12 months). Adjusted for confounders, the only significant between-group differences were a greater stepping time and step count for Group ORG + Tracker relative to Group ORG (+20.6 min/16 h day, 95 % CI: 3.1, 38.1, p = 0.021; +846.5steps/16 h day, 95 % CI: 67.8, 1625.2, p = 0.033) at 12 months. Observed changes in health and work outcomes were small and not statistically significant. Organisational-support strategies with or without an activity tracker resulted in improvements in sitting, prolonged sitting and standing; adding a tracker enhanced stepping changes. Improvements were most evident at 12 months, suggesting the organisational-support strategies may have taken time to embed within the organisation. Australian New Zealand Clinical Trial Registry: ACTRN12614000252617 . Registered 10 March 2014.

  8. Calibration of a dual-PTZ camera system for stereo vision

    NASA Astrophysics Data System (ADS)

    Chang, Yau-Zen; Hou, Jung-Fu; Tsao, Yi Hsiang; Lee, Shih-Tseng

    2010-08-01

    In this paper, we propose a calibration process for the intrinsic and extrinsic parameters of dual-PTZ camera systems. The calibration is based on a complete definition of six coordinate systems fixed at the image planes, and the pan and tilt rotation axes of the cameras. Misalignments between estimated and ideal coordinates of image corners are formed into cost values to be solved by the Nelder-Mead simplex optimization method. Experimental results show that the system is able to obtain 3D coordinates of objects with a consistent accuracy of 1 mm when the distance between the dual-PTZ camera set and the objects are from 0.9 to 1.1 meters.

  9. Geometrical calibration television measuring systems with solid state photodetectors

    NASA Astrophysics Data System (ADS)

    Matiouchenko, V. G.; Strakhov, V. V.; Zhirkov, A. O.

    2000-11-01

    The various optical measuring methods for deriving information about the size and form of objects are now used in difference branches- mechanical engineering, medicine, art, criminalistics. Measuring by means of the digital television systems is one of these methods. The development of this direction is promoted by occurrence on the market of various types and costs small-sized television cameras and frame grabbers. There are many television measuring systems using the expensive cameras, but accuracy performances of low cost cameras are also interested for the system developers. For this reason inexpensive mountingless camera SK1004CP (format 1/3', cost up to 40$) and frame grabber Aver2000 were used in experiments.

  10. The tympanic membrane displacement test and tinnitus: preliminary report on clinical observations, applications, and implications.

    PubMed

    Shulman, Abraham; Goldstein, Barbara; Marchbanks, Robert J

    2012-01-01

    The tympanic membrane displacement test (TMDT) is an attempt to record intracranial pressure (ICP) reflective of an intracranial pulse pressure amplitude wave (IPPA) transmitted to the inner ear and tympanic membrane with a probe placed into the external ear canal. Twelve tinnitus patients, divided into two groups, who were resistant to attempts to achieve tinnitus control or relief were selected for the TMDT. The group 1 TMDT recordings were obtained on one session test date, and group 2 (n = 6) recordings were obtained sequentially on different session test dates. Patient selection with the medical audiologic tinnitus patient protocol (MATPP) identified all to have a nonpulsatile, predominantly central-type severe disabling subjective idiopathic tinnitus (SIT) resistant to attempts for tinnitus relief with instrumentation or medication. Associated complaints in all selected SIT patients included persistent ear blockage in the SIT ear, normal middle-ear function, controlled secondary endolymphatic hydrops in the SIT ear, sensorineural hearing loss of high frequency, hyperacusis, occasional vertigo, and central nervous system complaints of headache, head pressure, and cognitive interference in memory and/or speech expression. Clinical concern is for the presence of an increased ICP reflecting an idiopathic intracranial hypertension (IIH) which, if not identified and treated, may be a factor influencing the clinical course of this particular cohort of SIT patients, highlighted by persistent ear blockage and associated complaints as described. We set out to accomplish a number of goals: (1) To identify abnormal intracranial pulse pressure (IPPA ICP) with the extracranial TMD in a preselected particular cohort of SIT patients clinically suspected (by use of the MATPP) to have an abnormal ICP (i.e., IIH); (2) to identify the abnormal IPPA ICP as a positive indicator for IIH and as a factor - not an etiology - influencing the clinical course of SIT in a preselected cohort of SIT patients; (3) to identify with the TMDT in SIT patients spontaneous nonevoked recordings of intra-aural pressure and test-retest reliability of the TMDT; (4) to identify with the TMDT levels of normal and abnormal IPPA ICP in real time in the clinical course of SIT (i.e., an objective diagnostic and treatment monitor function of the TMD targeting ICP and IIH before and after treatment); (5) to attempt to establish a correlation of treatment efficacy, targeting preand post-ICP as a manifestation of IIH, with SIT subjective tinnitus relief; (6) to identify the limitations and complications of the TMDT; and (7) to share with the reader the evolution of a new science of brain pulsatility and a technology having a clinical application for otology and neurotology complaints of hearing loss, tinnitus, ear blockage, and vertigo. The results reported in the literature complement and alter conventional medical teaching focusing on brain pulsation, absolute intracranial pressure, and brain disease. The Southampton Tympanic Membrane Displacement Analyzer was used to record spontaneous intra-aural pressure waves in 12 SIT patients. Patients selected for the TMDT were divided into two groups: Group 1 (n = 6) recordings were obtained on one session test date, and group 2 (n = 6) recordings were obtained sequentially on different session test dates. Multiple recordings were attempted in all patients to identify test-retest reliability in both groups. An attempt for treatment and control of an elevated ICP with or without reduced cerebral compliance (CC) was recommended in 4 patients. With single and multiple recordings using the TMDT, the IPPA (i.e., ICP) was demonstrated to be abnormal and to fluctuate in the clinical course of 10 of the 12 predominantly central-type tinnitus patients (SIT): abnormal IIPA with reduced CC in 8 of 12 patients and normal IPPA with reduced compliance in 2 of 12. Tinnitus treatment results targeting ICP as a manifestation of IIH with Diamox were positive in the short term in 2 patients and incomplete in 3. The SIT relief is reflective of fluctuation in the ICP and the overall issue of multifactorial brain pulsatility. (1) The TMDT demonstrated repeated and consistent spontaneous nonevoked recordings of displacement of the tympanic membrane, reflective of intra-aural pressure, abnormal IPPA ICP in a preselected particular cohort of SIT patients clinically suspected to have an abnormal ICP (i.e., IIH). (2) Test-retest reliability of the TMDT was positive. (3) The results of the TMDT application for identification of an elevated ICP and reduced CC were positive in 10 of 12 particular preselected patients with nonpulsatile, predominantly central-type SIT resistant to attempts for tinnitus relief with instrumentation or medication. These positive findings support clinical and basic science investigations previously reported in the literature. (4) The clinical significance of these preliminary results of an elevated ICP in a particular cohort of SIT patients supports the clinical impression of the presence of an IIH and its influence on the clinical course and overall treatment of SIT. (5) A final conclusion as to the clinical significance of an elevated ICP and reduced CC for IIH and the diagnosis and treatment of tinnitus remains to be established.

  11. Coincidence electron/ion imaging with a fast frame camera

    NASA Astrophysics Data System (ADS)

    Li, Wen; Lee, Suk Kyoung; Lin, Yun Fei; Lingenfelter, Steven; Winney, Alexander; Fan, Lin

    2015-05-01

    A new time- and position- sensitive particle detection system based on a fast frame CMOS camera is developed for coincidence electron/ion imaging. The system is composed of three major components: a conventional microchannel plate (MCP)/phosphor screen electron/ion imager, a fast frame CMOS camera and a high-speed digitizer. The system collects the positional information of ions/electrons from a fast frame camera through real-time centroiding while the arrival times are obtained from the timing signal of MCPs processed by a high-speed digitizer. Multi-hit capability is achieved by correlating the intensity of electron/ion spots on each camera frame with the peak heights on the corresponding time-of-flight spectrum. Efficient computer algorithms are developed to process camera frames and digitizer traces in real-time at 1 kHz laser repetition rate. We demonstrate the capability of this system by detecting a momentum-matched co-fragments pair (methyl and iodine cations) produced from strong field dissociative double ionization of methyl iodide. We further show that a time resolution of 30 ps can be achieved when measuring electron TOF spectrum and this enables the new system to achieve a good energy resolution along the TOF axis.

  12. An airborne multispectral imaging system based on two consumer-grade cameras for agricultural remote sensing

    USDA-ARS?s Scientific Manuscript database

    This paper describes the design and evaluation of an airborne multispectral imaging system based on two identical consumer-grade cameras for agricultural remote sensing. The cameras are equipped with a full-frame complementary metal oxide semiconductor (CMOS) sensor with 5616 × 3744 pixels. One came...

  13. Coincidence ion imaging with a fast frame camera

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Suk Kyoung; Cudry, Fadia; Lin, Yun Fei

    2014-12-15

    A new time- and position-sensitive particle detection system based on a fast frame CMOS (complementary metal-oxide semiconductors) camera is developed for coincidence ion imaging. The system is composed of four major components: a conventional microchannel plate/phosphor screen ion imager, a fast frame CMOS camera, a single anode photomultiplier tube (PMT), and a high-speed digitizer. The system collects the positional information of ions from a fast frame camera through real-time centroiding while the arrival times are obtained from the timing signal of a PMT processed by a high-speed digitizer. Multi-hit capability is achieved by correlating the intensity of ion spots onmore » each camera frame with the peak heights on the corresponding time-of-flight spectrum of a PMT. Efficient computer algorithms are developed to process camera frames and digitizer traces in real-time at 1 kHz laser repetition rate. We demonstrate the capability of this system by detecting a momentum-matched co-fragments pair (methyl and iodine cations) produced from strong field dissociative double ionization of methyl iodide.« less

  14. Research into a Single-aperture Light Field Camera System to Obtain Passive Ground-based 3D Imagery of LEO Objects

    NASA Astrophysics Data System (ADS)

    Bechis, K.; Pitruzzello, A.

    2014-09-01

    This presentation describes our ongoing research into using a ground-based light field camera to obtain passive, single-aperture 3D imagery of LEO objects. Light field cameras are an emerging and rapidly evolving technology for passive 3D imaging with a single optical sensor. The cameras use an array of lenslets placed in front of the camera focal plane, which provides angle of arrival information for light rays originating from across the target, allowing range to target and 3D image to be obtained from a single image using monocular optics. The technology, which has been commercially available for less than four years, has the potential to replace dual-sensor systems such as stereo cameras, dual radar-optical systems, and optical-LIDAR fused systems, thus reducing size, weight, cost, and complexity. We have developed a prototype system for passive ranging and 3D imaging using a commercial light field camera and custom light field image processing algorithms. Our light field camera system has been demonstrated for ground-target surveillance and threat detection applications, and this paper presents results of our research thus far into applying this technology to the 3D imaging of LEO objects. The prototype 3D imaging camera system developed by Northrop Grumman uses a Raytrix R5 C2GigE light field camera connected to a Windows computer with an nVidia graphics processing unit (GPU). The system has a frame rate of 30 Hz, and a software control interface allows for automated camera triggering and light field image acquisition to disk. Custom image processing software then performs the following steps: (1) image refocusing, (2) change detection, (3) range finding, and (4) 3D reconstruction. In Step (1), a series of 2D images are generated from each light field image; the 2D images can be refocused at up to 100 different depths. Currently, steps (1) through (3) are automated, while step (4) requires some user interaction. A key requirement for light field camera operation is that the target must be within the near-field (Fraunhofer distance) of the collecting optics. For example, in visible light the near-field of a 1-m telescope extends out to about 3,500 km, while the near-field of the AEOS telescope extends out over 46,000 km. For our initial proof of concept, we have integrated our light field camera with a 14-inch Meade LX600 advanced coma-free telescope, to image various surrogate ground targets at up to tens of kilometers range. Our experiments with the 14-inch telescope have assessed factors and requirements that are traceable and scalable to a larger-aperture system that would have the near-field distance needed to obtain 3D images of LEO objects. The next step would be to integrate a light field camera with a 1-m or larger telescope and evaluate its 3D imaging capability against LEO objects. 3D imaging of LEO space objects with light field camera technology can potentially provide a valuable new tool for space situational awareness, especially for those situations where laser or radar illumination of the target objects is not feasible.

  15. An evaluation of video cameras for collecting observational data on sanctuary-housed chimpanzees (Pan troglodytes).

    PubMed

    Hansen, Bethany K; Fultz, Amy L; Hopper, Lydia M; Ross, Stephen R

    2018-05-01

    Video cameras are increasingly being used to monitor captive animals in zoo, laboratory, and agricultural settings. This technology may also be useful in sanctuaries with large and/or complex enclosures. However, the cost of camera equipment and a lack of formal evaluations regarding the use of cameras in sanctuary settings make it challenging for facilities to decide whether and how to implement this technology. To address this, we evaluated the feasibility of using a video camera system to monitor chimpanzees at Chimp Haven. We viewed a group of resident chimpanzees in a large forested enclosure and compared observations collected in person and with remote video cameras. We found that via camera, the observer viewed fewer chimpanzees in some outdoor locations (GLMM post hoc test: est. = 1.4503, SE = 0.1457, Z = 9.951, p < 0.001) and identified a lower proportion of chimpanzees (GLMM post hoc test: est. = -2.17914, SE = 0.08490, Z = -25.666, p < 0.001) compared to in-person observations. However, the observer could view the 2 ha enclosure 15 times faster by camera compared to in person. In addition to these results, we provide recommendations to animal facilities considering the installation of a video camera system. Despite some limitations of remote monitoring, we posit that there are substantial benefits of using camera systems in sanctuaries to facilitate animal care and observational research. © 2018 Wiley Periodicals, Inc.

  16. Object tracking using multiple camera video streams

    NASA Astrophysics Data System (ADS)

    Mehrubeoglu, Mehrube; Rojas, Diego; McLauchlan, Lifford

    2010-05-01

    Two synchronized cameras are utilized to obtain independent video streams to detect moving objects from two different viewing angles. The video frames are directly correlated in time. Moving objects in image frames from the two cameras are identified and tagged for tracking. One advantage of such a system involves overcoming effects of occlusions that could result in an object in partial or full view in one camera, when the same object is fully visible in another camera. Object registration is achieved by determining the location of common features in the moving object across simultaneous frames. Perspective differences are adjusted. Combining information from images from multiple cameras increases robustness of the tracking process. Motion tracking is achieved by determining anomalies caused by the objects' movement across frames in time in each and the combined video information. The path of each object is determined heuristically. Accuracy of detection is dependent on the speed of the object as well as variations in direction of motion. Fast cameras increase accuracy but limit the speed and complexity of the algorithm. Such an imaging system has applications in traffic analysis, surveillance and security, as well as object modeling from multi-view images. The system can easily be expanded by increasing the number of cameras such that there is an overlap between the scenes from at least two cameras in proximity. An object can then be tracked long distances or across multiple cameras continuously, applicable, for example, in wireless sensor networks for surveillance or navigation.

  17. Real-time depth camera tracking with geometrically stable weight algorithm

    NASA Astrophysics Data System (ADS)

    Fu, Xingyin; Zhu, Feng; Qi, Feng; Wang, Mingming

    2017-03-01

    We present an approach for real-time camera tracking with depth stream. Existing methods are prone to drift in sceneries without sufficient geometric information. First, we propose a new weight method for an iterative closest point algorithm commonly used in real-time dense mapping and tracking systems. By detecting uncertainty in pose and increasing weight of points that constrain unstable transformations, our system achieves accurate and robust trajectory estimation results. Our pipeline can be fully parallelized with GPU and incorporated into the current real-time depth camera tracking system seamlessly. Second, we compare the state-of-the-art weight algorithms and propose a weight degradation algorithm according to the measurement characteristics of a consumer depth camera. Third, we use Nvidia Kepler Shuffle instructions during warp and block reduction to improve the efficiency of our system. Results on the public TUM RGB-D database benchmark demonstrate that our camera tracking system achieves state-of-the-art results both in accuracy and efficiency.

  18. Intraocular camera for retinal prostheses: Refractive and diffractive lens systems

    NASA Astrophysics Data System (ADS)

    Hauer, Michelle Christine

    The focus of this thesis is on the design and analysis of refractive, diffractive, and hybrid refractive/diffractive lens systems for a miniaturized camera that can be surgically implanted in the crystalline lens sac and is designed to work in conjunction with current and future generation retinal prostheses. The development of such an intraocular camera (IOC) would eliminate the need for an external head-mounted or eyeglass-mounted camera. Placing the camera inside the eye would allow subjects to use their natural eye movements for foveation (attention) instead of more cumbersome head tracking, would notably aid in personal navigation and mobility, and would also be significantly more psychologically appealing from the standpoint of personal appearances. The capability for accommodation with no moving parts or feedback control is incorporated by employing camera designs that exhibit nearly infinite depth of field. Such an ultracompact optical imaging system requires a unique combination of refractive and diffractive optical elements and relaxed system constraints derived from human psychophysics. This configuration necessitates an extremely compact, short focal-length lens system with an f-number close to unity. Initially, these constraints appear highly aggressive from an optical design perspective. However, after careful analysis of the unique imaging requirements of a camera intended to work in conjunction with the relatively low pixellation levels of a retinal microstimulator array, it becomes clear that such a design is not only feasible, but could possibly be implemented with a single lens system.

  19. Orbital-science investigation: Part C: photogrammetry of Apollo 15 photography

    USGS Publications Warehouse

    Wu, Sherman S.C.; Schafer, Francis J.; Jordan, Raymond; Nakata, Gary M.; Derick, James L.

    1972-01-01

    Mapping of large areas of the Moon by photogrammetric methods was not seriously considered until the Apollo 15 mission. In this mission, a mapping camera system and a 61-cm optical-bar high-resolution panoramic camera, as well as a laser altimeter, were used. The mapping camera system comprises a 7.6-cm metric terrain camera and a 7.6-cm stellar camera mounted in a fixed angular relationship (an angle of 96° between the two camera axes). The metric camera has a glass focal-plane plate with reseau grids. The ground-resolution capability from an altitude of 110 km is approximately 20 m. Because of the auxiliary stellar camera and the laser altimeter, the resulting metric photography can be used not only for medium- and small-scale cartographic or topographic maps, but it also can provide a basis for establishing a lunar geodetic network. The optical-bar panoramic camera has a 135- to 180-line resolution, which is approximately 1 to 2 m of ground resolution from an altitude of 110 km. Very large scale specialized topographic maps for supporting geologic studies of lunar-surface features can be produced from the stereoscopic coverage provided by this camera.

  20. SpectraCAM SPM: a camera system with high dynamic range for scientific and medical applications

    NASA Astrophysics Data System (ADS)

    Bhaskaran, S.; Baiko, D.; Lungu, G.; Pilon, M.; VanGorden, S.

    2005-08-01

    A scientific camera system having high dynamic range designed and manufactured by Thermo Electron for scientific and medical applications is presented. The newly developed CID820 image sensor with preamplifier-per-pixel technology is employed in this camera system. The 4 Mega-pixel imaging sensor has a raw dynamic range of 82dB. Each high-transparent pixel is based on a preamplifier-per-pixel architecture and contains two photogates for non-destructive readout of the photon-generated charge (NDRO). Readout is achieved via parallel row processing with on-chip correlated double sampling (CDS). The imager is capable of true random pixel access with a maximum operating speed of 4MHz. The camera controller consists of a custom camera signal processor (CSP) with an integrated 16-bit A/D converter and a PowerPC-based CPU running a Linux embedded operating system. The imager is cooled to -40C via three-stage cooler to minimize dark current. The camera housing is sealed and is designed to maintain the CID820 imager in the evacuated chamber for at least 5 years. Thermo Electron has also developed custom software and firmware to drive the SpectraCAM SPM camera. Included in this firmware package is the new Extreme DRTM algorithm that is designed to extend the effective dynamic range of the camera by several orders of magnitude up to 32-bit dynamic range. The RACID Exposure graphical user interface image analysis software runs on a standard PC that is connected to the camera via Gigabit Ethernet.

  1. Digital dental photography. Part 4: choosing a camera.

    PubMed

    Ahmad, I

    2009-06-13

    With so many cameras and systems on the market, making a choice of the right one for your practice needs is a daunting task. As described in Part 1 of this series, a digital single reflex (DSLR) camera is an ideal choice for dental use in enabling the taking of portraits, close-up or macro images of the dentition and study casts. However, for the sake of completion, some other cameras systems that are used in dentistry are also discussed.

  2. Detection of Prosthetic Knee Movement Phases via In-Socket Sensors: A Feasibility Study

    PubMed Central

    El-Sayed, Amr M.; Tan, Kenneth Y. S.; Abu Osman, Noor Azuan

    2015-01-01

    This paper presents an approach of identifying prosthetic knee movements through pattern recognition of mechanical responses at the internal socket's wall. A quadrilateral double socket was custom made and instrumented with two force sensing resistors (FSR) attached to specific anterior and posterior sites of the socket's wall. A second setup was established by attaching three piezoelectric sensors at the anterior distal, anterior proximal, and posterior sites. Gait cycle and locomotion movements such as stair ascent and sit to stand were adopted to characterize the validity of the technique. FSR and piezoelectric outputs were measured with reference to the knee angle during each phase. Piezoelectric sensors could identify the movement of midswing and terminal swing, pre-full standing, pull-up at gait, sit to stand, and stair ascent. In contrast, FSR could estimate the gait cycle stance and swing phases and identify the pre-full standing at sit to stand. FSR showed less variation during sit to stand and stair ascent to sensitively represent the different movement states. The study highlighted the capacity of using in-socket sensors for knee movement identification. In addition, it validated the efficacy of the system and warrants further investigation with more amputee subjects and different sockets types. PMID:25945365

  3. A cycling workstation to facilitate physical activity in office settings.

    PubMed

    Elmer, Steven J; Martin, James C

    2014-07-01

    Facilitating physical activity during the workday may help desk-bound workers reduce risks associated with sedentary behavior. We 1) evaluated the efficacy of a cycling workstation to increase energy expenditure while performing a typing task and 2) fabricated a power measurement system to determine the accuracy and reliability of an exercise cycle. Ten individuals performed 10 min trials of sitting while typing (SIT type) and pedaling while typing (PED type). Expired gases were recorded and typing performance was assessed. Metabolic cost during PED type was ∼ 2.5 × greater compared to SIT type (255 ± 14 vs. 100 ± 11 kcal h(-1), P < 0.01). Typing time and number of typing errors did not differ between PED type and SIT type (7.7 ± 1.5 vs. 7.6 ± 1.6 min, P = 0.51, 3.3 ± 4.6 vs. 3.8 ± 2.7 errors, P = 0.80). The exercise cycle overestimated power by 14-138% compared to actual power but actual power was reliable (r = 0.998, P < 0.01). A cycling workstation can facilitate physical activity without compromising typing performance. The exercise cycle's inaccuracy could be misleading to users. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  4. The new camera calibration system at the US Geological Survey

    USGS Publications Warehouse

    Light, D.L.

    1992-01-01

    Modern computerized photogrammetric instruments are capable of utilizing both radial and decentering camera calibration parameters which can increase plotting accuracy over that of older analog instrumentation technology from previous decades. Also, recent design improvements in aerial cameras have minimized distortions and increased the resolving power of camera systems, which should improve the performance of the overall photogrammetric process. In concert with these improvements, the Geological Survey has adopted the rigorous mathematical model for camera calibration developed by Duane Brown. An explanation of the Geological Survey's calibration facility and the additional calibration parameters now being provided in the USGS calibration certificate are reviewed. -Author

  5. 3D display for enhanced tele-operation and other applications

    NASA Astrophysics Data System (ADS)

    Edmondson, Richard; Pezzaniti, J. Larry; Vaden, Justin; Hyatt, Brian; Morris, James; Chenault, David; Bodenhamer, Andrew; Pettijohn, Bradley; Tchon, Joe; Barnidge, Tracy; Kaufman, Seth; Kingston, David; Newell, Scott

    2010-04-01

    In this paper, we report on the use of a 3D vision field upgrade kit for TALON robot consisting of a replacement flat panel stereoscopic display, and multiple stereo camera systems. An assessment of the system's use for robotic driving, manipulation, and surveillance operations was conducted. A replacement display, replacement mast camera with zoom, auto-focus, and variable convergence, and a replacement gripper camera with fixed focus and zoom comprise the upgrade kit. The stereo mast camera allows for improved driving and situational awareness as well as scene survey. The stereo gripper camera allows for improved manipulation in typical TALON missions.

  6. An on-line calibration algorithm for external parameters of visual system based on binocular stereo cameras

    NASA Astrophysics Data System (ADS)

    Wang, Liqiang; Liu, Zhen; Zhang, Zhonghua

    2014-11-01

    Stereo vision is the key in the visual measurement, robot vision, and autonomous navigation. Before performing the system of stereo vision, it needs to calibrate the intrinsic parameters for each camera and the external parameters of the system. In engineering, the intrinsic parameters remain unchanged after calibrating cameras, and the positional relationship between the cameras could be changed because of vibration, knocks and pressures in the vicinity of the railway or motor workshops. Especially for large baselines, even minute changes in translation or rotation can affect the epipolar geometry and scene triangulation to such a degree that visual system becomes disabled. A technology including both real-time examination and on-line recalibration for the external parameters of stereo system becomes particularly important. This paper presents an on-line method for checking and recalibrating the positional relationship between stereo cameras. In epipolar geometry, the external parameters of cameras can be obtained by factorization of the fundamental matrix. Thus, it offers a method to calculate the external camera parameters without any special targets. If the intrinsic camera parameters are known, the external parameters of system can be calculated via a number of random matched points. The process is: (i) estimating the fundamental matrix via the feature point correspondences; (ii) computing the essential matrix from the fundamental matrix; (iii) obtaining the external parameters by decomposition of the essential matrix. In the step of computing the fundamental matrix, the traditional methods are sensitive to noise and cannot ensure the estimation accuracy. We consider the feature distribution situation in the actual scene images and introduce a regional weighted normalization algorithm to improve accuracy of the fundamental matrix estimation. In contrast to traditional algorithms, experiments on simulated data prove that the method improves estimation robustness and accuracy of the fundamental matrix. Finally, we take an experiment for computing the relationship of a pair of stereo cameras to demonstrate accurate performance of the algorithm.

  7. The Surgeon's View: Comparison of Two Digital Video Recording Systems in Veterinary Surgery.

    PubMed

    Giusto, Gessica; Caramello, Vittorio; Comino, Francesco; Gandini, Marco

    2015-01-01

    Video recording and photography during surgical procedures are useful in veterinary medicine for several reasons, including legal, educational, and archival purposes. Many systems are available, such as hand cameras, light-mounted cameras, and head cameras. We chose a reasonably priced head camera that is among the smallest video cameras available. To best describe its possible uses and advantages, we recorded video and images of eight different surgical cases and procedures, both in hospital and field settings. All procedures were recorded both with a head-mounted camera and a commercial hand-held photo camera. Then sixteen volunteers (eight senior clinicians and eight final-year students) completed an evaluation questionnaire. Both cameras produced high-quality photographs and videos, but observers rated the head camera significantly better regarding point of view and their understanding of the surgical operation. The head camera was considered significantly more useful in teaching surgical procedures. Interestingly, senior clinicians tended to assign generally lower scores compared to students. The head camera we tested is an effective, easy-to-use tool for recording surgeries and various veterinary procedures in all situations, with no need for assistance from a dedicated operator. It can be a valuable aid for veterinarians working in all fields of the profession and a useful tool for veterinary surgical education.

  8. RESTORATION OF ATMOSPHERICALLY DEGRADED IMAGES. VOLUME 3.

    DTIC Science & Technology

    AERIAL CAMERAS, LASERS, ILLUMINATION, TRACKING CAMERAS, DIFFRACTION, PHOTOGRAPHIC GRAIN, DENSITY, DENSITOMETERS, MATHEMATICAL ANALYSIS, OPTICAL SCANNING, SYSTEMS ENGINEERING, TURBULENCE, OPTICAL PROPERTIES, SATELLITE TRACKING SYSTEMS.

  9. Development of two-framing camera with large format and ultrahigh speed

    NASA Astrophysics Data System (ADS)

    Jiang, Xiaoguo; Wang, Yuan; Wang, Yi

    2012-10-01

    High-speed imaging facility is important and necessary for the formation of time-resolved measurement system with multi-framing capability. The framing camera which satisfies the demands of both high speed and large format needs to be specially developed in the ultrahigh speed research field. A two-framing camera system with high sensitivity and time-resolution has been developed and used for the diagnosis of electron beam parameters of Dragon-I linear induction accelerator (LIA). The camera system, which adopts the principle of light beam splitting in the image space behind the lens with long focus length, mainly consists of lens-coupled gated image intensifier, CCD camera and high-speed shutter trigger device based on the programmable integrated circuit. The fastest gating time is about 3 ns, and the interval time between the two frames can be adjusted discretely at the step of 0.5 ns. Both the gating time and the interval time can be tuned to the maximum value of about 1 s independently. Two images with the size of 1024×1024 for each can be captured simultaneously in our developed camera. Besides, this camera system possesses a good linearity, uniform spatial response and an equivalent background illumination as low as 5 electrons/pix/sec, which fully meets the measurement requirements of Dragon-I LIA.

  10. Feasibility of using the radiation-based sterile insect technique (SIT) to control the olive fruit fly, Bactrocera oleae Gmelin (Diptera: Tephritidae) in Iran.

    PubMed

    Ahmadi, Mehrdad; Salehi, Bahareh; Abd-Alla, Adly M M; Babaie, Mohammad

    2018-05-30

    Bactrocera oleae is one of the most hazardous pests threatening olive orchards in Iran. SIT is an environment-friendly system of pest control based on releasing sterile males able to compete with wild males to mate with wild females. To determine sterile doses of radiation, pupae were irradiated to the doses of 0-160 Gy. Doses of 90-100 Gy were found optimal providing the necessary sterilization without severely impairing the competitiveness of the irradiated males in mating. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. 12th Annual Systems Engineering Conference

    DTIC Science & Technology

    2009-10-29

    pl em en...io n of Le sso ns L ea rn ed fr om C om pl ex S ys te m o f Sy ste m s A cq ui sit io ns D r. Ri ch ar d Tu rn er , St ev en s I ns tit ut...hn ol og y Tr an sit io n Pl an ni ng Th ro ug h th e U se o f St ag e- G at es – U pd at e M r. R an dy B ul la rd , U .S . A ir Fo

  12. Sitting ducks face chronic disease: an analysis of newspaper coverage of sedentary behaviour as a health issue in Australia 2000-2012.

    PubMed

    Chau, Josephine Y; Bonfiglioli, Catriona; Zhong, Amy; Pedisic, Zeljko; Daley, Michelle; McGill, Bronwyn; Bauman, Adrian

    2017-08-01

    Issue addressed This study examines how sedentary behaviour (too much sitting) was covered as a health issue by Australian newspapers and how physical activity was framed within this newspaper coverage. Methods Articles featuring sedentary behaviour published in Australian newspapers between 2000 and 2012 were analysed for content and framing. Main outcome measures were volume, number and content of newspaper articles; framing and types of sedentary behaviour; responsibility for the problem of and solutions to high levels of sedentary behaviour; and physical activity mentions and how it was framed within sedentary behaviour coverage. Results Out of 48 articles, prolonged sitting was framed as bad for health (52%) and specifically as health compromising for office workers (25%). Adults who sat a lot were framed as 'easy targets' for ill health (21% of headlines led with 'sitting ducks' or 'sitting targets'). Prolonged sitting was framed as an issue of individual responsibility (>90%) with less mention of environmental and sociocultural contributors. Thirty-six of 48 articles mentioned physical activity; 39% stated that being physically active does not matter if a person sits for prolonged periods of time or that the benefits of physical activity are undone by too much sitting. Conclusions News coverage should reflect the full socio-ecological model of sedentary behaviour and continually reinforce the independent and well-established benefits of health-enhancing physical activity alongside the need to limit prolonged sitting. So what? It is important that the entire 'move more, sit less, every day!' message is communicated by news media.

  13. Sit-stand desks in call centres: associations of use and ergonomics awareness with sedentary behavior.

    PubMed

    Straker, Leon; Abbott, Rebecca A; Heiden, Marina; Mathiassen, Svend Erik; Toomingas, Allan

    2013-07-01

    To investigate whether or not use of sit-stand desks and awareness of the importance of postural variation and breaks are associated with the pattern of sedentary behavior in office workers. The data came from a cross-sectional observation study of Swedish call centre workers. Inclinometers recorded 'seated' or 'standing/walking' episodes of 131 operators over a full work shift. Differences in sedentary behavior based on desk type and awareness of the importance of posture variation and breaks were assessed by non-parametric analyses. 90 (68.7%) operators worked at a sit-stand desk. Working at a sit-stand desk, as opposed to a sit desk, was associated with less time seated (78.5 vs 83.8%, p = 0.010), and less time taken to accumulate 5 min of standing/walking (36.2 vs 46.3 min, p = 0.022), but no significant difference to sitting episode length or the number of switches between sitting and standing/walking per hour. Ergonomics awareness was not associated with any sedentary pattern variable among those using a sit-stand desk. Use of sit-stand desks was associated with better sedentary behavior in call centre workers, however ergonomics awareness did not enhance the effect. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  14. Uprising: An examination of sit-stand workstations, mental health and work ability in sedentary office workers, in Western Australia.

    PubMed

    Tobin, Rochelle; Leavy, Justine; Jancey, Jonine

    2016-10-17

    Office-based staff spend around three quarters of their work day sitting. People who sit for long periods while at work are at greater risk of adverse health outcomes. The pilot study aimed to determine the effect of sit-stand workstations on office-based staff sedentary and physical activity behaviors, work ability and self-reported physical and mental health outcomes. A two-group pre-post study design assessed changes in sedentary and physical activity behaviors (time spent sitting, standing and stepping and sit-stand transitions and number of steps taken) work ability and physical and mental health. Physical activity behaviors were measured using activPAL activity monitors and self-reported data on work ability and physical and mental health were collected using an online questionnaire. Relative to the controls (n=19), the intervention group (n=18) significantly decreased time spent sitting by 100 minutes (p<0.001) and increased standing time by 99 minutes (p<0.001). There was a decrease in self-reported current work ability when compared to lifetime best (p=0.008). There were no significant differences for all other sedentary behavior, other workability outcomes, physical health or mental health outcomes at follow-up. The Uprising Study found that sit-stand workstations are an effective strategy to reduce occupational sitting time in office-based workers over a one month period.

  15. Development of Open source-based automatic shooting and processing UAV imagery for Orthoimage Using Smart Camera UAV

    NASA Astrophysics Data System (ADS)

    Park, J. W.; Jeong, H. H.; Kim, J. S.; Choi, C. U.

    2016-06-01

    Recently, aerial photography with unmanned aerial vehicle (UAV) system uses UAV and remote controls through connections of ground control system using bandwidth of about 430 MHz radio Frequency (RF) modem. However, as mentioned earlier, existing method of using RF modem has limitations in long distance communication. The Smart Camera equipments's LTE (long-term evolution), Bluetooth, and Wi-Fi to implement UAV that uses developed UAV communication module system carried out the close aerial photogrammetry with the automatic shooting. Automatic shooting system is an image capturing device for the drones in the area's that needs image capturing and software for loading a smart camera and managing it. This system is composed of automatic shooting using the sensor of smart camera and shooting catalog management which manages filmed images and information. Processing UAV imagery module used Open Drone Map. This study examined the feasibility of using the Smart Camera as the payload for a photogrammetric UAV system. The open soure tools used for generating Android, OpenCV (Open Computer Vision), RTKLIB, Open Drone Map.

  16. Ranging Apparatus and Method Implementing Stereo Vision System

    NASA Technical Reports Server (NTRS)

    Li, Larry C. (Inventor); Cox, Brian J. (Inventor)

    1997-01-01

    A laser-directed ranging system for use in telerobotics applications and other applications involving physically handicapped individuals. The ranging system includes a left and right video camera mounted on a camera platform, and a remotely positioned operator. The position of the camera platform is controlled by three servo motors to orient the roll axis, pitch axis and yaw axis of the video cameras, based upon an operator input such as head motion. A laser is provided between the left and right video camera and is directed by the user to point to a target device. The images produced by the left and right video cameras are processed to eliminate all background images except for the spot created by the laser. This processing is performed by creating a digital image of the target prior to illumination by the laser, and then eliminating common pixels from the subsequent digital image which includes the laser spot. The horizontal disparity between the two processed images is calculated for use in a stereometric ranging analysis from which range is determined.

  17. Stability analysis for a multi-camera photogrammetric system.

    PubMed

    Habib, Ayman; Detchev, Ivan; Kwak, Eunju

    2014-08-18

    Consumer-grade digital cameras suffer from geometrical instability that may cause problems when used in photogrammetric applications. This paper provides a comprehensive review of this issue of interior orientation parameter variation over time, it explains the common ways used for coping with the issue, and describes the existing methods for performing stability analysis for a single camera. The paper then points out the lack of coverage of stability analysis for multi-camera systems, suggests a modification of the collinearity model to be used for the calibration of an entire photogrammetric system, and proposes three methods for system stability analysis. The proposed methods explore the impact of the changes in interior orientation and relative orientation/mounting parameters on the reconstruction process. Rather than relying on ground truth in real datasets to check the system calibration stability, the proposed methods are simulation-based. Experiment results are shown, where a multi-camera photogrammetric system was calibrated three times, and stability analysis was performed on the system calibration parameters from the three sessions. The proposed simulation-based methods provided results that were compatible with a real-data based approach for evaluating the impact of changes in the system calibration parameters on the three-dimensional reconstruction.

  18. Enhanced technologies for unattended ground sensor systems

    NASA Astrophysics Data System (ADS)

    Hartup, David C.

    2010-04-01

    Progress in several technical areas is being leveraged to advantage in Unattended Ground Sensor (UGS) systems. This paper discusses advanced technologies that are appropriate for use in UGS systems. While some technologies provide evolutionary improvements, other technologies result in revolutionary performance advancements for UGS systems. Some specific technologies discussed include wireless cameras and viewers, commercial PDA-based system programmers and monitors, new materials and techniques for packaging improvements, low power cueing sensor radios, advanced long-haul terrestrial and SATCOM radios, and networked communications. Other technologies covered include advanced target detection algorithms, high pixel count cameras for license plate and facial recognition, small cameras that provide large stand-off distances, video transmissions of target activity instead of still images, sensor fusion algorithms, and control center hardware. The impact of each technology on the overall UGS system architecture is discussed, along with the advantages provided to UGS system users. Areas of analysis include required camera parameters as a function of stand-off distance for license plate and facial recognition applications, power consumption for wireless cameras and viewers, sensor fusion communication requirements, and requirements to practically implement video transmission through UGS systems. Examples of devices that have already been fielded using technology from several of these areas are given.

  19. Low-cost, portable, robust and high-resolution single-camera stereo-DIC system and its application in high-temperature deformation measurements

    NASA Astrophysics Data System (ADS)

    Chi, Yuxi; Yu, Liping; Pan, Bing

    2018-05-01

    A low-cost, portable, robust and high-resolution single-camera stereo-digital image correlation (stereo-DIC) system for accurate surface three-dimensional (3D) shape and deformation measurements is described. This system adopts a single consumer-grade high-resolution digital Single Lens Reflex (SLR) camera and a four-mirror adaptor, rather than two synchronized industrial digital cameras, for stereo image acquisition. In addition, monochromatic blue light illumination and coupled bandpass filter imaging are integrated to ensure the robustness of the system against ambient light variations. In contrast to conventional binocular stereo-DIC systems, the developed pseudo-stereo-DIC system offers the advantages of low cost, portability, robustness against ambient light variations, and high resolution. The accuracy and precision of the developed single SLR camera-based stereo-DIC system were validated by measuring the 3D shape of a stationary sphere along with in-plane and out-of-plane displacements of a translated planar plate. Application of the established system to thermal deformation measurement of an alumina ceramic plate and a stainless-steel plate subjected to radiation heating was also demonstrated.

  20. Stability Analysis for a Multi-Camera Photogrammetric System

    PubMed Central

    Habib, Ayman; Detchev, Ivan; Kwak, Eunju

    2014-01-01

    Consumer-grade digital cameras suffer from geometrical instability that may cause problems when used in photogrammetric applications. This paper provides a comprehensive review of this issue of interior orientation parameter variation over time, it explains the common ways used for coping with the issue, and describes the existing methods for performing stability analysis for a single camera. The paper then points out the lack of coverage of stability analysis for multi-camera systems, suggests a modification of the collinearity model to be used for the calibration of an entire photogrammetric system, and proposes three methods for system stability analysis. The proposed methods explore the impact of the changes in interior orientation and relative orientation/mounting parameters on the reconstruction process. Rather than relying on ground truth in real datasets to check the system calibration stability, the proposed methods are simulation-based. Experiment results are shown, where a multi-camera photogrammetric system was calibrated three times, and stability analysis was performed on the system calibration parameters from the three sessions. The proposed simulation-based methods provided results that were compatible with a real-data based approach for evaluating the impact of changes in the system calibration parameters on the three-dimensional reconstruction. PMID:25196012

  1. Periodically Relieving Ischial Sitting Load to Decrease the Risk of Pressure Ulcers

    PubMed Central

    Makhsous, Mohsen; Rowles, Diane M.; Rymer, William Z.; Bankard, James; Nam, Ellis K.; Chen, David; Lin, Fang

    2010-01-01

    Objective To investigate the relieving effect on interface pressure of an alternate sitting protocol involving a sitting posture that reduces ischial support. Design Repeated measures in 2 protocols on 3 groups of subjects. Setting Laboratory. Participants Twenty able-bodied persons, 20 persons with paraplegia, and 20 persons with tetraplegia. Interventions Two 1-hour protocols were used: alternate and normal plus pushup. In the alternate protocol, sitting posture was alternated every 10 minutes between normal (sitting upright with ischial support) and with partially removed ischial support (WO-BPS) postures; in the normal plus pushup protocol, sitting was in normal posture with pushups (lifting the subject off the seat) performed every 20 minutes. Main Outcome Measure Interface pressure on seat and backrest. Results In WO-BPS posture, the concentrated interface pressure observed around the ischia in normal posture was significantly repositioned to the thighs. By cyclically repositioning the interface pressure, the alternate protocol was superior to the normal plus pushup protocol in terms of a significantly lower average interface pressure over the buttocks. Conclusions A sitting protocol periodically reducing the ischial support helps lower the sitting load on the buttocks, especially the area close to ischial tuberosities. PMID:17601466

  2. 640x480 PtSi Stirling-cooled camera system

    NASA Astrophysics Data System (ADS)

    Villani, Thomas S.; Esposito, Benjamin J.; Davis, Timothy J.; Coyle, Peter J.; Feder, Howard L.; Gilmartin, Harvey R.; Levine, Peter A.; Sauer, Donald J.; Shallcross, Frank V.; Demers, P. L.; Smalser, P. J.; Tower, John R.

    1992-09-01

    A Stirling cooled 3 - 5 micron camera system has been developed. The camera employs a monolithic 640 X 480 PtSi-MOS focal plane array. The camera system achieves an NEDT equals 0.10 K at 30 Hz frame rate with f/1.5 optics (300 K background). At a spatial frequency of 0.02 cycles/mRAD the vertical and horizontal Minimum Resolvable Temperature are in the range of MRT equals 0.03 K (f/1.5 optics, 300 K background). The MOS focal plane array achieves a resolution of 480 TV lines per picture height independent of background level and position within the frame.

  3. Automatic Calibration of an Airborne Imaging System to an Inertial Navigation Unit

    NASA Technical Reports Server (NTRS)

    Ansar, Adnan I.; Clouse, Daniel S.; McHenry, Michael C.; Zarzhitsky, Dimitri V.; Pagdett, Curtis W.

    2013-01-01

    This software automatically calibrates a camera or an imaging array to an inertial navigation system (INS) that is rigidly mounted to the array or imager. In effect, it recovers the coordinate frame transformation between the reference frame of the imager and the reference frame of the INS. This innovation can automatically derive the camera-to-INS alignment using image data only. The assumption is that the camera fixates on an area while the aircraft flies on orbit. The system then, fully automatically, solves for the camera orientation in the INS frame. No manual intervention or ground tie point data is required.

  4. Solid state television camera

    NASA Technical Reports Server (NTRS)

    1976-01-01

    The design, fabrication, and tests of a solid state television camera using a new charge-coupled imaging device are reported. An RCA charge-coupled device arranged in a 512 by 320 format and directly compatible with EIA format standards was the sensor selected. This is a three-phase, sealed surface-channel array that has 163,840 sensor elements, which employs a vertical frame transfer system for image readout. Included are test results of the complete camera system, circuit description and changes to such circuits as a result of integration and test, maintenance and operation section, recommendations to improve the camera system, and a complete set of electrical and mechanical drawing sketches.

  5. A Portable Shoulder-Mounted Camera System for Surgical Education in Spine Surgery.

    PubMed

    Pham, Martin H; Ohiorhenuan, Ifije E; Patel, Neil N; Jakoi, Andre M; Hsieh, Patrick C; Acosta, Frank L; Wang, Jeffrey C; Liu, John C

    2017-02-07

    The past several years have demonstrated an increased recognition of operative videos as an important adjunct for resident education. Currently lacking, however, are effective methods to record video for the purposes of illustrating the techniques of minimally invasive (MIS) and complex spine surgery. We describe here our experiences developing and using a shoulder-mounted camera system for recording surgical video. Our requirements for an effective camera system included wireless portability to allow for movement around the operating room, camera mount location for comfort and loupes/headlight usage, battery life for long operative days, and sterile control of on/off recording. With this in mind, we created a shoulder-mounted camera system utilizing a GoPro™ HERO3+, its Smart Remote (GoPro, Inc., San Mateo, California), a high-capacity external battery pack, and a commercially available shoulder-mount harness. This shoulder-mounted system was more comfortable to wear for long periods of time in comparison to existing head-mounted and loupe-mounted systems. Without requiring any wired connections, the surgeon was free to move around the room as needed. Over the past several years, we have recorded numerous MIS and complex spine surgeries for the purposes of surgical video creation for resident education. Surgical videos serve as a platform to distribute important operative nuances in rich multimedia. Effective and practical camera system setups are needed to encourage the continued creation of videos to illustrate the surgical maneuvers in minimally invasive and complex spinal surgery. We describe here a novel portable shoulder-mounted camera system setup specifically designed to be worn and used for long periods of time in the operating room.

  6. First results of the multi-purpose real-time processing video camera system on the Wendelstein 7-X stellarator and implications for future devices

    NASA Astrophysics Data System (ADS)

    Zoletnik, S.; Biedermann, C.; Cseh, G.; Kocsis, G.; König, R.; Szabolics, T.; Szepesi, T.; Wendelstein 7-X Team

    2018-01-01

    A special video camera has been developed for the 10-camera overview video system of the Wendelstein 7-X (W7-X) stellarator considering multiple application needs and limitations resulting from this complex long-pulse superconducting stellarator experiment. The event detection intelligent camera (EDICAM) uses a special 1.3 Mpixel CMOS sensor with non-destructive read capability which enables fast monitoring of smaller Regions of Interest (ROIs) even during long exposures. The camera can perform simple data evaluation algorithms (minimum/maximum, mean comparison to levels) on the ROI data which can dynamically change the readout process and generate output signals. Multiple EDICAM cameras were operated in the first campaign of W7-X and capabilities were explored in the real environment. Data prove that the camera can be used for taking long exposure (10-100 ms) overview images of the plasma while sub-ms monitoring and even multi-camera correlated edge plasma turbulence measurements of smaller areas can be done in parallel. These latter revealed that filamentary turbulence structures extend between neighboring modules of the stellarator. Considerations emerging for future upgrades of this system and similar setups on future long-pulse fusion experiments such as ITER are discussed.

  7. Frequency of postural changes during sitting whilst using a desktop computer--exploring an analytical methodology.

    PubMed

    Niekerk, Sjan-Mari van; Louw, Quinette Abigail; Grimmer-Sommers, Karen

    2014-01-01

    Dynamic movement whilst sitting is advocated as a way to reduce musculoskeletal symptoms from seated activities. Conventionally, in ergonomics research, only a 'snapshot' of static sitting posture is captured, which does not provide information on the number or type of movements over a period of time. A novel approach to analyse the number of postural changes whist sitting was employed in order to describe the sitting behaviour of adolescents whilst undertaking computing activities. A repeated-measures observational study was conducted. A total of 12 high school students were randomly selected from a conveniently selected school. Fifteen minutes of 3D posture measurements were recorded to determine the number of postural changes whilst using computers. Data of 11 students were able to be analysed. Large intra-subject variation of the median and IQR was observed, indicating frequent postural changes whilst sitting. Better understanding of usual dynamic postural movements whilst sitting will provide new insights into causes of musculoskeletal symptoms experienced by computer users.

  8. The Association of Sitting Time With Sarcopenia Status and Physical Performance at Baseline and 18-Month Follow-Up in the Residential Aged Care Setting.

    PubMed

    Reid, Natasha; Keogh, Justin W; Swinton, Paul; Gardiner, Paul A; Henwood, Timothy R

    2018-06-18

    This study investigated the association of sitting time with sarcopenia and physical performance in residential aged care residents at baseline and 18-month follow-up. Measures included the International Physical Activity Questionnaire (sitting time), European Working Group definition of sarcopenia, and the short physical performance battery (physical performance). Logistic regression and linear regression analyses were used to investigate associations. For each hour of sitting, the unadjusted odds ratio of sarcopenia was 1.16 (95% confidence interval [0.98, 1.37]). Linear regression showed that each hour of sitting was significantly associated with a 0.2-unit lower score for performance. Associations of baseline sitting with follow-up sarcopenia status and performance were nonsignificant. Cross-sectionally, increased sitting time in residential aged care may be detrimentally associated with sarcopenia and physical performance. Based on current reablement models of care, future studies should investigate if reducing sedentary time improves performance among adults in end of life care.

  9. Photometric Calibration and Image Stitching for a Large Field of View Multi-Camera System

    PubMed Central

    Lu, Yu; Wang, Keyi; Fan, Gongshu

    2016-01-01

    A new compact large field of view (FOV) multi-camera system is introduced. The camera is based on seven tiny complementary metal-oxide-semiconductor sensor modules covering over 160° × 160° FOV. Although image stitching has been studied extensively, sensor and lens differences have not been considered in previous multi-camera devices. In this study, we have calibrated the photometric characteristics of the multi-camera device. Lenses were not mounted on the sensor in the process of radiometric response calibration to eliminate the influence of the focusing effect of uniform light from an integrating sphere. Linearity range of the radiometric response, non-linearity response characteristics, sensitivity, and dark current of the camera response function are presented. The R, G, and B channels have different responses for the same illuminance. Vignetting artifact patterns have been tested. The actual luminance of the object is retrieved by sensor calibration results, and is used to blend images to make panoramas reflect the objective luminance more objectively. This compensates for the limitation of stitching images that are more realistic only through the smoothing method. The dynamic range limitation of can be resolved by using multiple cameras that cover a large field of view instead of a single image sensor with a wide-angle lens. The dynamic range is expanded by 48-fold in this system. We can obtain seven images in one shot with this multi-camera system, at 13 frames per second. PMID:27077857

  10. Mission Report on the Orbiter Camera Payload System (OCPS) Large Format Camera (LFC) and Attitude Reference System (ARS)

    NASA Technical Reports Server (NTRS)

    Mollberg, Bernard H.; Schardt, Bruton B.

    1988-01-01

    The Orbiter Camera Payload System (OCPS) is an integrated photographic system which is carried into earth orbit as a payload in the Space Transportation System (STS) Orbiter vehicle's cargo bay. The major component of the OCPS is a Large Format Camera (LFC), a precision wide-angle cartographic instrument that is capable of producing high resolution stereo photography of great geometric fidelity in multiple base-to-height (B/H) ratios. A secondary, supporting system to the LFC is the Attitude Reference System (ARS), which is a dual lens Stellar Camera Array (SCA) and camera support structure. The SCA is a 70-mm film system which is rigidly mounted to the LFC lens support structure and which, through the simultaneous acquisition of two star fields with each earth-viewing LFC frame, makes it possible to determine precisely the pointing of the LFC optical axis with reference to the earth nadir point. Other components complete the current OCPS configuration as a high precision cartographic data acquisition system. The primary design objective for the OCPS was to maximize system performance characteristics while maintaining a high level of reliability compatible with Shuttle launch conditions and the on-orbit environment. The full-up OCPS configuration was launched on a highly successful maiden voyage aboard the STS Orbiter vehicle Challenger on October 5, 1984, as a major payload aboard mission STS 41-G. This report documents the system design, the ground testing, the flight configuration, and an analysis of the results obtained during the Challenger mission STS 41-G.

  11. Stereoscopic 3D reconstruction using motorized zoom lenses within an embedded system

    NASA Astrophysics Data System (ADS)

    Liu, Pengcheng; Willis, Andrew; Sui, Yunfeng

    2009-02-01

    This paper describes a novel embedded system capable of estimating 3D positions of surfaces viewed by a stereoscopic rig consisting of a pair of calibrated cameras. Novel theoretical and technical aspects of the system are tied to two aspects of the design that deviate from typical stereoscopic reconstruction systems: (1) incorporation of an 10x zoom lens (Rainbow- H10x8.5) and (2) implementation of the system on an embedded system. The system components include a DSP running μClinux, an embedded version of the Linux operating system, and an FPGA. The DSP orchestrates data flow within the system and performs complex computational tasks and the FPGA provides an interface to the system devices which consist of a CMOS camera pair and a pair of servo motors which rotate (pan) each camera. Calibration of the camera pair is accomplished using a collection of stereo images that view a common chess board calibration pattern for a set of pre-defined zoom positions. Calibration settings for an arbitrary zoom setting are estimated by interpolation of the camera parameters. A low-computational cost method for dense stereo matching is used to compute depth disparities for the stereo image pairs. Surface reconstruction is accomplished by classical triangulation of the matched points from the depth disparities. This article includes our methods and results for the following problems: (1) automatic computation of the focus and exposure settings for the lens and camera sensor, (2) calibration of the system for various zoom settings and (3) stereo reconstruction results for several free form objects.

  12. The effect of anti-IgE treatment on in vitro leukotriene release in children with seasonal allergic rhinitis.

    PubMed

    Kopp, Matthias Volkmar; Brauburger, Jens; Riedinger, Frank; Beischer, Dorothee; Ihorst, Gabriele; Kamin, Wolfgang; Zielen, Stefan; Bez; Friedrichs, Frank; Von Berg, Andrea; Gerhold, Kerstin; Hamelmann, Eckard; Hultsch; Kuehr, Joachim

    2002-11-01

    Binding of allergens with IgE to the IgE receptors on mast cells and basophils results in the release of inflammatory mediators as sulfidoleukotrienes (SLTs), triggering allergic cascades that result in allergic symptoms, such as asthma and rhinitis. We sought to investigate whether anti-IgE (Oma-lizumab), a humanized monoclonal anti-IgE antibody, in addition to specific immunotherapy (SIT) affects the leukotriene pathway. Ninety-two children (age range, 6-17 years) with sensitization to birch and grass pollens and with seasonal allergic rhinitis were included in a phase III, placebo- controlled, multicenter clinical study. All subjects were randomized to one of 4 treatment groups. Two groups subcutaneously received birch SIT and 2 groups received grass SIT for at least 14 weeks before the start of the birch pollen season. After 12 weeks of SIT titration, placebo or anti-IgE was added for 24 weeks. The primary clinical efficacy variable was symptom load (ie, the sum of daily symptom severity score and rescue medication score during pollen season). Blood samples taken at baseline and at the end of study treatment after the grass pollen season were used for separation of leukocytes in this substudy. After in vitro stimulation of the blood cells with grass and birch pollen allergens, SLT release (LTC4, LTD4, and LTE4) was quantified by using the ELISA technique. Before the study treatment, SLT release to birch and grass pollen exposure did not differ significantly among the 4 groups. Under treatment with anti-IgE + SIT-grass (n = 23), a lower symptom load occurred during the pollen season compared to placebo + SIT-grass (n = 24, P =.012). The same applied to both groups receiving birch SIT (n = 23 and n = 22, respectively; P =.03). At the end of treatment, the combination of anti-IgE plus grass SIT, as well as anti-IgE plus birch SIT, resulted in significantly lower SLT release after stimulation with the corresponding allergen (416 ng/L [5th-95th percentile, 1-1168] and 207 ng/L [1-860 ng/L], respectively) compared with placebo plus SIT (2490 ng/L [384-6587 ng/L], P =.001; 2489 ng/L [1-5670 ng/L], P =.001). In addition, treatment with anti-IgE was also followed by significantly lower SLT releases to the allergens unrelated to SIT (grass SIT: 300 ng/L [1-2432 ng/L] in response to birch allergen; birch SIT: 1478 ng/L [1-4593 ng/L] in response to grass pollen) in comparison with placebo (grass SIT: 1850 ng/L [1-5499 ng/L], P =.001; birch SIT: 2792 ng/L [154-5839 ng/L], P =.04]. Anti-IgE therapy reduces leukotriene release of peripheral leukocytes stimulated with allergen in children with allergic rhinitis undergoing allergen immunotherapy independent of the type of SIT allergen used.

  13. HERCULES/MSI: a multispectral imager with geolocation for STS-70

    NASA Astrophysics Data System (ADS)

    Simi, Christopher G.; Kindsfather, Randy; Pickard, Henry; Howard, William, III; Norton, Mark C.; Dixon, Roberta

    1995-11-01

    A multispectral intensified CCD imager combined with a ring laser gyroscope based inertial measurement unit was flown on the Space Shuttle Discovery from July 13-22, 1995 (Space Transport System Flight No. 70, STS-70). The camera includes a six position filter wheel, a third generation image intensifier, and a CCD camera. The camera is integrated with a laser gyroscope system that determines the ground position of the imagery to an accuracy of better than three nautical miles. The camera has two modes of operation; a panchromatic mode for high-magnification imaging [ground sample distance (GSD) of 4 m], or a multispectral mode consisting of six different user-selectable spectral ranges at reduced magnification (12 m GSD). This paper discusses the system hardware and technical trade-offs involved with camera optimization, and presents imagery observed during the shuttle mission.

  14. 3D vision upgrade kit for TALON robot

    NASA Astrophysics Data System (ADS)

    Edmondson, Richard; Vaden, Justin; Hyatt, Brian; Morris, James; Pezzaniti, J. Larry; Chenault, David B.; Tchon, Joe; Barnidge, Tracy; Kaufman, Seth; Pettijohn, Brad

    2010-04-01

    In this paper, we report on the development of a 3D vision field upgrade kit for TALON robot consisting of a replacement flat panel stereoscopic display, and multiple stereo camera systems. An assessment of the system's use for robotic driving, manipulation, and surveillance operations was conducted. The 3D vision system was integrated onto a TALON IV Robot and Operator Control Unit (OCU) such that stock components could be electrically disconnected and removed, and upgrade components coupled directly to the mounting and electrical connections. A replacement display, replacement mast camera with zoom, auto-focus, and variable convergence, and a replacement gripper camera with fixed focus and zoom comprise the upgrade kit. The stereo mast camera allows for improved driving and situational awareness as well as scene survey. The stereo gripper camera allows for improved manipulation in typical TALON missions.

  15. Feasibility study of transmission of OTV camera control information in the video vertical blanking interval

    NASA Technical Reports Server (NTRS)

    White, Preston A., III

    1994-01-01

    The Operational Television system at Kennedy Space Center operates hundreds of video cameras, many remotely controllable, in support of the operations at the center. This study was undertaken to determine if commercial NABTS (North American Basic Teletext System) teletext transmission in the vertical blanking interval of the genlock signals distributed to the cameras could be used to send remote control commands to the cameras and the associated pan and tilt platforms. Wavelength division multiplexed fiberoptic links are being installed in the OTV system to obtain RS-250 short-haul quality. It was demonstrated that the NABTS transmission could be sent over the fiberoptic cable plant without excessive video quality degradation and that video cameras could be controlled using NABTS transmissions over multimode fiberoptic paths as long as 1.2 km.

  16. Touch And Go Camera System (TAGCAMS) for the OSIRIS-REx Asteroid Sample Return Mission

    NASA Astrophysics Data System (ADS)

    Bos, B. J.; Ravine, M. A.; Caplinger, M.; Schaffner, J. A.; Ladewig, J. V.; Olds, R. D.; Norman, C. D.; Huish, D.; Hughes, M.; Anderson, S. K.; Lorenz, D. A.; May, A.; Jackman, C. D.; Nelson, D.; Moreau, M.; Kubitschek, D.; Getzandanner, K.; Gordon, K. E.; Eberhardt, A.; Lauretta, D. S.

    2018-02-01

    NASA's OSIRIS-REx asteroid sample return mission spacecraft includes the Touch And Go Camera System (TAGCAMS) three camera-head instrument. The purpose of TAGCAMS is to provide imagery during the mission to facilitate navigation to the target asteroid, confirm acquisition of the asteroid sample, and document asteroid sample stowage. The cameras were designed and constructed by Malin Space Science Systems (MSSS) based on requirements developed by Lockheed Martin and NASA. All three of the cameras are mounted to the spacecraft nadir deck and provide images in the visible part of the spectrum, 400-700 nm. Two of the TAGCAMS cameras, NavCam 1 and NavCam 2, serve as fully redundant navigation cameras to support optical navigation and natural feature tracking. Their boresights are aligned in the nadir direction with small angular offsets for operational convenience. The third TAGCAMS camera, StowCam, provides imagery to assist with and confirm proper stowage of the asteroid sample. Its boresight is pointed at the OSIRIS-REx sample return capsule located on the spacecraft deck. All three cameras have at their heart a 2592 × 1944 pixel complementary metal oxide semiconductor (CMOS) detector array that provides up to 12-bit pixel depth. All cameras also share the same lens design and a camera field of view of roughly 44° × 32° with a pixel scale of 0.28 mrad/pixel. The StowCam lens is focused to image features on the spacecraft deck, while both NavCam lens focus positions are optimized for imaging at infinity. A brief description of the TAGCAMS instrument and how it is used to support critical OSIRIS-REx operations is provided.

  17. Comparison of parameters of modern cooled and uncooled thermal cameras

    NASA Astrophysics Data System (ADS)

    Bareła, Jarosław; Kastek, Mariusz; Firmanty, Krzysztof; Krupiński, Michał

    2017-10-01

    During the design of a system employing thermal cameras one always faces a problem of choosing the camera types best suited for the task. In many cases such a choice is far from optimal one, and there are several reasons for that. System designers often favor tried and tested solution they are used to. They do not follow the latest developments in the field of infrared technology and sometimes their choices are based on prejudice and not on facts. The paper presents the results of measurements of basic parameters of MWIR and LWIR thermal cameras, carried out in a specialized testing laboratory. The measured parameters are decisive in terms of image quality generated by thermal cameras. All measurements were conducted according to current procedures and standards. However the camera settings were not optimized for a specific test conditions or parameter measurements. Instead the real settings used in normal camera operations were applied to obtain realistic camera performance figures. For example there were significant differences between measured values of noise parameters and catalogue data provided by manufacturers, due to the application of edge detection filters to increase detection and recognition ranges. The purpose of this paper is to provide help in choosing the optimal thermal camera for particular application, answering the question whether to opt for cheaper microbolometer device or apply slightly better (in terms of specifications) yet more expensive cooled unit. Measurements and analysis were performed by qualified personnel with several dozen years of experience in both designing and testing of thermal camera systems with both cooled and uncooled focal plane arrays. Cameras of similar array sizes and optics were compared, and for each tested group the best performing devices were selected.

  18. System for controlling child safety seat environment

    NASA Technical Reports Server (NTRS)

    Elrod, Susan V. (Inventor); Dabney, Richard W. (Inventor)

    2008-01-01

    A system is provided to control the environment experienced by a child in a child safety seat. Each of a plurality of thermoelectric elements is individually controllable to be one of heated and cooled relative to an ambient temperature. A first portion of the thermoelectric elements are positioned on the child safety seat such that a child sitting therein is positioned thereover. A ventilator coupled to the child safety seat moves air past a second portion of the thermoelectric elements and filters the air moved therepast. One or more jets coupled to the ventilator receive the filtered air. Each jet is coupled to the child safety seat and can be positioned to direct the heated/cooled filtered air to the vicinity of the head of the child sitting in the child safety seat.

  19. Comparative genomic analysis and characterization of incompatibility group FIB plasmid encoded virulence factors of Salmonella enterica isolated from food sources.

    PubMed

    Khajanchi, Bijay K; Hasan, Nur A; Choi, Seon Young; Han, Jing; Zhao, Shaohua; Colwell, Rita R; Cerniglia, Carl E; Foley, Steven L

    2017-08-02

    The degree to which the chromosomal mediated iron acquisition system contributes to virulence of many bacterial pathogens is well defined. However, the functional roles of plasmid encoded iron acquisition systems, specifically Sit and aerobactin, have yet to be determined for Salmonella spp. In a recent study, Salmonella enterica strains isolated from different food sources were sequenced on the Illumina MiSeq platform and found to harbor the incompatibility group (Inc) FIB plasmid. In this study, we examined sequence diversity and the contribution of factors encoded on the IncFIB plasmid to the virulence of S. enterica. Whole genome sequences of seven S. enterica isolates were compared to genomes of serovars of S. enterica isolated from food, animal, and human sources. SeqSero analysis predicted that six strains were serovar Typhimurium and one was Heidelberg. Among the S. Typhimurium strains, single nucleotide polymorphism (SNP)-based phylogenetic analyses revealed that five of the isolates clustered as a single monophyletic S. Typhimurium subclade, while one of the other strains branched with S. Typhimurium from a bovine source. DNA sequence based phylogenetic diversity analyses showed that the IncFIB plasmid-encoded Sit and aerobactin iron acquisition systems are conserved among bacterial species including S. enterica. The IncFIB plasmid was transferred to an IncFIB plasmid deficient strain of S. enterica by conjugation. The transconjugant SE819::IncFIB persisted in human intestinal epithelial (Caco-2) cells at a higher rate than the recipient SE819. Genes of the Sit and aerobactin operons in the IncFIB plasmid were differentially expressed in iron-rich and iron-depleted growth media. Minimal sequence diversity was detected in the Sit and aerobactin operons in the IncFIB plasmids present among different bacterial species, including foodborne Salmonella strains. IncFIB plasmid encoded factors play a role during infection under low-iron conditions in host cells.

  20. Perspectives on a ‘Sit Less, Move More’ Intervention in Australian Emergency Call Centres

    PubMed Central

    Chau, Josephine Y; Engelen, Lina; Burks-Young, Sarah; Daley, Michelle; Maxwell, Jen-Kui; Milton, Karen; Bauman, Adrian

    2016-01-01

    Background Prolonged sitting is associated with increased risk of chronic diseases. Workplace programs that aim to reduce sitting time (sit less) and increase physical activity (move more) have targeted desk-based workers in corporate and university settings with promising results. However, little is known about ‘move more, sit less’ programs for workers in other types of jobs and industries, such as shift workers. This formative research examines the perceptions of a ‘sit less, move more’ program in an Australian Emergency Call Centre that operates 24 hours per day, 7 days per week. Methods Participants were employees (N = 39, 72% female, 50% aged 36–55 years) recruited from Emergency Services control centres located in New South Wales, Australia. The ‘sit less, move more’ intervention, consisting of emails, posters and timer lights, was co-designed with the management team and tailored to the control centre environment and work practices, which already included electronic height-adjustable sit-stand workstations for all call centre staff. Participants reported their perceptions and experiences of the intervention in a self-report online questionnaire, and directly to the research team during regular site visits. Questionnaire topics included barriers and facilitators to standing while working, mental wellbeing, effects on work performance, and workplace satisfaction. Field notes and open-ended response data were analysed in an iterative process during and after data collection to identify the main themes. Results Whilst participants already had sit-stand workstations, use of the desks in the standing position varied and sometimes were contrary to expectations (e.g, less tired standing than sitting; standing when experiencing high call stress). Participants emphasised the “challenging” and “unrelenting” nature of their work. They reported sleep issues (“always tired”), work stress (“non-stop demands”), and feeling mentally and physically drained due to shift work and length of shifts. Overall, participants liked the initiative but acknowledged that their predominantly sitting habits were entrenched and work demands took precedence. Conclusions This study demonstrates the low acceptability of a ‘sit less, move more’ program in shift workers in high stress environments like emergency call centres. Work demands take priority and other health concerns, like poor sleep and high stress, may be more salient than the need to sit less and move more during work shifts. PMID:29546163

  1. Perspectives on a 'Sit Less, Move More' Intervention in Australian Emergency Call Centres.

    PubMed

    Chau, Josephine Y; Engelen, Lina; Burks-Young, Sarah; Daley, Michelle; Maxwell, Jen-Kui; Milton, Karen; Bauman, Adrian

    2016-01-01

    Prolonged sitting is associated with increased risk of chronic diseases. Workplace programs that aim to reduce sitting time (sit less) and increase physical activity (move more) have targeted desk-based workers in corporate and university settings with promising results. However, little is known about 'move more, sit less' programs for workers in other types of jobs and industries, such as shift workers. This formative research examines the perceptions of a 'sit less, move more' program in an Australian Emergency Call Centre that operates 24 hours per day, 7 days per week. Participants were employees (N = 39, 72% female, 50% aged 36-55 years) recruited from Emergency Services control centres located in New South Wales, Australia. The 'sit less, move more' intervention, consisting of emails, posters and timer lights, was co-designed with the management team and tailored to the control centre environment and work practices, which already included electronic height-adjustable sit-stand workstations for all call centre staff. Participants reported their perceptions and experiences of the intervention in a self-report online questionnaire, and directly to the research team during regular site visits. Questionnaire topics included barriers and facilitators to standing while working, mental wellbeing, effects on work performance, and workplace satisfaction. Field notes and open-ended response data were analysed in an iterative process during and after data collection to identify the main themes. Whilst participants already had sit-stand workstations, use of the desks in the standing position varied and sometimes were contrary to expectations (e.g, less tired standing than sitting; standing when experiencing high call stress). Participants emphasised the "challenging" and "unrelenting" nature of their work. They reported sleep issues ("always tired"), work stress ("non-stop demands"), and feeling mentally and physically drained due to shift work and length of shifts. Overall, participants liked the initiative but acknowledged that their predominantly sitting habits were entrenched and work demands took precedence. This study demonstrates the low acceptability of a 'sit less, move more' program in shift workers in high stress environments like emergency call centres. Work demands take priority and other health concerns, like poor sleep and high stress, may be more salient than the need to sit less and move more during work shifts.

  2. Analysis of Mycobacterium tuberculosis Genotypic Lineage Distribution in Chile and Neighboring Countries

    PubMed Central

    Lagos, Jaime; Couvin, David; Arata, Loredana; Tognarelli, Javier; Aguayo, Carolina; Leiva, Tamara; Arias, Fabiola; Hormazabal, Juan Carlos; Rastogi, Nalin; Fernández, Jorge

    2016-01-01

    Tuberculosis (TB), caused by the pathogen Mycobacterium tuberculosis (MTB), remains a disease of high importance to global public health. Studies into the population structure of MTB have become vital to monitoring possible outbreaks and also to develop strategies regarding disease control. Although Chile has a low incidence of MTB, the current rates of migration have the potential to change this scenario. We collected and analyzed a total of 458 M. tuberculosis isolates (1 isolate per patient) originating from all 15 regions of Chile. The isolates were genotyped using the spoligotyping method and the data obtained were analyzed and compared with the SITVIT2 database. A total of 169 different patterns were identified, of which, 119 patterns (408 strains) corresponded to Spoligotype International Types (SITs) and 50 patterns corresponded to orphan strains. The most abundantly represented SITs/lineages were: SIT53/T1 (11.57%), SIT33/LAM3 (9.6%), SIT42/LAM9 (9.39%), SIT50/H3 (5.9%), SIT37/T3 (5%); analysis of the spoligotyping minimum spanning tree as well as spoligoforest were suggestive of a recent expansion of SIT42, SIT50 and SIT37; all of which potentially evolved from SIT53. The most abundantly represented lineages were LAM (40.6%), T (34.1%) and Haarlem (13.5%). LAM was more prevalent in the Santiago (43.6%) and Concepción (44.1%) isolates, rather than the Iquique (29.4%) strains. The proportion of X lineage was appreciably higher in Iquique and Concepción (11.7% in both) as compared to Santiago (1.6%). Global analysis of MTB lineage distribution in Chile versus neighboring countries showed that evolutionary recent lineages (LAM, T and Haarlem) accounted together for 88.2% of isolates in Chile, a pattern which mirrored MTB lineage distribution in neighboring countries (n = 7378 isolates recorded in SITVIT2 database for Peru, Brazil, Paraguay, and Argentina; and published studies), highlighting epidemiological advantage of Euro-American lineages in this region. Finally, we also observed exclusive emergence of patterns SIT4014/X1 and SIT4015 (unknown lineage signature) that have hitherto been found exclusively in Chile, indicating that conditions specific to Chile, along with the unique genetic makeup of the Chilean population, might have allowed for a possible co-evolution leading to the success of these emerging genotypes. PMID:27518286

  3. Does the addition of virtual reality training to a standard program of inpatient rehabilitation improve sitting balance ability and function after stroke? Protocol for a single-blind randomized controlled trial.

    PubMed

    Sheehy, L; Taillon-Hobson, A; Sveistrup, H; Bilodeau, M; Fergusson, D; Levac, D; Finestone, H

    2016-03-31

    Sitting ability and function are commonly impaired after stroke. Balance training has been shown to be helpful, but abundant repetitions are required for optimal recovery and patients must be motivated to perform rehabilitation exercises repeatedly to maximize treatment intensity. Virtual reality training (VRT), which allows patients to interact with a virtual environment using computer software and hardware, is enjoyable and may encourage greater repetition of therapeutic exercises. However, the potential for VRT to promote sitting balance has not yet been explored. The objective of this study is to determine if supplemental VRT-based sitting balance exercises improve sitting balance ability and function in stroke rehabilitation inpatients. This is a single-site, single-blind, parallel-group randomized control trial. Seventy six stroke rehabilitation inpatients who cannot stand independently for greater than one minute but can sit for at least 20 minutes (including at least one minute without support) are being recruited from a tertiary-care dedicated stroke rehabilitation unit. Participants are randomly allocated to experimental or control groups. Both participate in 10-12 sessions of 30-45 minutes of VRT performed in sitting administered by a single physiotherapist, in addition to their traditional therapy. The experimental group plays five games which challenge sitting balance while the control group plays five games which minimize trunk lean. Outcome measures of sitting balance ability (Function in Sitting Test, Ottawa Sitting Scale, quantitative measures of postural sway) and function (Reaching Performance Scale, Wolf Motor Function Test, quantitative measures of the limits of stability) are administered prior to, immediately following, and one month following the intervention by a second physiotherapist blind to the participant's group allocation. The treatment of sitting balance post-stroke with VRT has not yet been explored. Results from the current study will provide important evidence for the use of low-cost, accessible VRT as an adjunct intervention to increase sitting balance in lower-functioning patients receiving inpatient rehabilitation. The motivating and enjoyable attributes of VRT may increase exercise dosage, leading to improved function and optimal results from rehabilitation. https://clinicaltrials.gov/; Identifier: NCT02285933. Registered 06 November 2014. Funded by the Heart & Stroke Foundation of Canada and a generous donation from Tony & Elizabeth Graham.

  4. Application of single-image camera calibration for ultrasound augmented laparoscopic visualization

    NASA Astrophysics Data System (ADS)

    Liu, Xinyang; Su, He; Kang, Sukryool; Kane, Timothy D.; Shekhar, Raj

    2015-03-01

    Accurate calibration of laparoscopic cameras is essential for enabling many surgical visualization and navigation technologies such as the ultrasound-augmented visualization system that we have developed for laparoscopic surgery. In addition to accuracy and robustness, there is a practical need for a fast and easy camera calibration method that can be performed on demand in the operating room (OR). Conventional camera calibration methods are not suitable for the OR use because they are lengthy and tedious. They require acquisition of multiple images of a target pattern in its entirety to produce satisfactory result. In this work, we evaluated the performance of a single-image camera calibration tool (rdCalib; Percieve3D, Coimbra, Portugal) featuring automatic detection of corner points in the image, whether partial or complete, of a custom target pattern. Intrinsic camera parameters of a 5-mm and a 10-mm standard Stryker® laparoscopes obtained using rdCalib and the well-accepted OpenCV camera calibration method were compared. Target registration error (TRE) as a measure of camera calibration accuracy for our optical tracking-based AR system was also compared between the two calibration methods. Based on our experiments, the single-image camera calibration yields consistent and accurate results (mean TRE = 1.18 ± 0.35 mm for the 5-mm scope and mean TRE = 1.13 ± 0.32 mm for the 10-mm scope), which are comparable to the results obtained using the OpenCV method with 30 images. The new single-image camera calibration method is promising to be applied to our augmented reality visualization system for laparoscopic surgery.

  5. Application of single-image camera calibration for ultrasound augmented laparoscopic visualization

    PubMed Central

    Liu, Xinyang; Su, He; Kang, Sukryool; Kane, Timothy D.; Shekhar, Raj

    2017-01-01

    Accurate calibration of laparoscopic cameras is essential for enabling many surgical visualization and navigation technologies such as the ultrasound-augmented visualization system that we have developed for laparoscopic surgery. In addition to accuracy and robustness, there is a practical need for a fast and easy camera calibration method that can be performed on demand in the operating room (OR). Conventional camera calibration methods are not suitable for the OR use because they are lengthy and tedious. They require acquisition of multiple images of a target pattern in its entirety to produce satisfactory result. In this work, we evaluated the performance of a single-image camera calibration tool (rdCalib; Percieve3D, Coimbra, Portugal) featuring automatic detection of corner points in the image, whether partial or complete, of a custom target pattern. Intrinsic camera parameters of a 5-mm and a 10-mm standard Stryker® laparoscopes obtained using rdCalib and the well-accepted OpenCV camera calibration method were compared. Target registration error (TRE) as a measure of camera calibration accuracy for our optical tracking-based AR system was also compared between the two calibration methods. Based on our experiments, the single-image camera calibration yields consistent and accurate results (mean TRE = 1.18 ± 0.35 mm for the 5-mm scope and mean TRE = 1.13 ± 0.32 mm for the 10-mm scope), which are comparable to the results obtained using the OpenCV method with 30 images. The new single-image camera calibration method is promising to be applied to our augmented reality visualization system for laparoscopic surgery. PMID:28943703

  6. Application of single-image camera calibration for ultrasound augmented laparoscopic visualization.

    PubMed

    Liu, Xinyang; Su, He; Kang, Sukryool; Kane, Timothy D; Shekhar, Raj

    2015-03-01

    Accurate calibration of laparoscopic cameras is essential for enabling many surgical visualization and navigation technologies such as the ultrasound-augmented visualization system that we have developed for laparoscopic surgery. In addition to accuracy and robustness, there is a practical need for a fast and easy camera calibration method that can be performed on demand in the operating room (OR). Conventional camera calibration methods are not suitable for the OR use because they are lengthy and tedious. They require acquisition of multiple images of a target pattern in its entirety to produce satisfactory result. In this work, we evaluated the performance of a single-image camera calibration tool ( rdCalib ; Percieve3D, Coimbra, Portugal) featuring automatic detection of corner points in the image, whether partial or complete, of a custom target pattern. Intrinsic camera parameters of a 5-mm and a 10-mm standard Stryker ® laparoscopes obtained using rdCalib and the well-accepted OpenCV camera calibration method were compared. Target registration error (TRE) as a measure of camera calibration accuracy for our optical tracking-based AR system was also compared between the two calibration methods. Based on our experiments, the single-image camera calibration yields consistent and accurate results (mean TRE = 1.18 ± 0.35 mm for the 5-mm scope and mean TRE = 1.13 ± 0.32 mm for the 10-mm scope), which are comparable to the results obtained using the OpenCV method with 30 images. The new single-image camera calibration method is promising to be applied to our augmented reality visualization system for laparoscopic surgery.

  7. Measurement of Separated Flow Structures Using a Multiple-Camera DPIV System. [conducted in the Langley Subsonic Basic Research Tunnel

    NASA Technical Reports Server (NTRS)

    Humphreys, William M., Jr.; Bartram, Scott M.

    2001-01-01

    A novel multiple-camera system for the recording of digital particle image velocimetry (DPIV) images acquired in a two-dimensional separating/reattaching flow is described. The measurements were performed in the NASA Langley Subsonic Basic Research Tunnel as part of an overall series of experiments involving the simultaneous acquisition of dynamic surface pressures and off-body velocities. The DPIV system utilized two frequency-doubled Nd:YAG lasers to generate two coplanar, orthogonally polarized light sheets directed upstream along the horizontal centerline of the test model. A recording system containing two pairs of matched high resolution, 8-bit cameras was used to separate and capture images of illuminated tracer particles embedded in the flow field. Background image subtraction was used to reduce undesirable flare light emanating from the surface of the model, and custom pixel alignment algorithms were employed to provide accurate registration among the various cameras. Spatial cross correlation analysis with median filter validation was used to determine the instantaneous velocity structure in the separating/reattaching flow region illuminated by the laser light sheets. In operation the DPIV system exhibited a good ability to resolve large-scale separated flow structures with acceptable accuracy over the extended field of view of the cameras. The recording system design provided enhanced performance versus traditional DPIV systems by allowing a variety of standard and non-standard cameras to be easily incorporated into the system.

  8. Two-stage soil infiltration treatment system for treating ammonium wastewaters of low COD/TN ratios.

    PubMed

    Lei, Zhongfang; Wu, Ting; Zhang, Yi; Liu, Xiang; Wan, Chunli; Lee, Duu-Jong; Tay, Joo-Hwa

    2013-01-01

    Soil infiltration treatment (SIT) is ineffective to treat ammonium wastewaters of total nitrogen (TN) > 100 mg l(-1). This study applied a novel two-stage SIT process for effective TN removal from wastewaters of TN>100 mg l(-1) and of chemical oxygen demand (COD)/TN ratio of 3.2-8.6. The wastewater was first fed into the soil column (stage 1) at hydraulic loading rate (HLR) of 0.06 m(3) m(-2) d(-1) for COD removal and total phosphorus (TP) immobilization. Then the effluent from stage 1 was fed individually into four soil columns (stage 2) at 0.02 m(3) m(-2) d(-1) of HLR with different proportions of raw wastewater as additional carbon source. Over the one-year field test, balanced nitrification and denitrification in the two-stage SIT revealed excellent TN removal (>90%) from the tested wastewaters. Copyright © 2012 Elsevier Ltd. All rights reserved.

  9. A Cluster Randomized Controlled Trial to Reduce Office Workers' Sitting Time: Effect on Activity Outcomes.

    PubMed

    Healy, Genevieve N; Eakin, Elizabeth G; Owen, Neville; Lamontagne, Anthony D; Moodie, Marj; Winkler, Elisabeth A H; Fjeldsoe, Brianna S; Wiesner, Glen; Willenberg, Lisa; Dunstan, David W

    2016-09-01

    This study aimed to evaluate the initial and long-term effectiveness of a workplace intervention compared with usual practice, targeting the reduction of sitting on activity outcomes. Office worksites (≥1 km apart) from a single organization in Victoria, Australia, were cluster randomized to intervention (n = 7) or control (n = 7). Participants were 231 desk-based office workers (5-39 participants per worksite) working at least 0.6 full-time equivalent. The workplace-delivered intervention addressed organizational, physical environment, and individual behavioral changes to reduce sitting time. Assessments occurred at baseline, 3 months, and 12 months, with the primary outcome participants' objectively measured (activPAL3 device) workplace sitting time (minutes per 8-h workday). Secondary activity outcomes were workplace time spent standing, stepping (light, moderate to vigorous, and total), and in prolonged (≥30 min) sitting bouts (hours per 8-h workday); usual duration of workplace sitting bouts; and overall sitting, standing, and stepping time (minutes per 16-h day). Analysis was by linear mixed models, accounting for repeated-measures and clustering and adjusting for baseline values and potential confounders. At baseline, on average, participants (68% women; mean ± SD age = 45.6 ± 9.4 yr) sat, stood, and stepped for 78.8% ± 9.5%, 14.3% ± 8.2%, and 6.9% ± 2.9% of work hours, respectively. Workplace sitting time was significantly reduced in the intervention group compared with the controls at 3 months (-99.1 [95% confidence interval = -116.3 to -81.8] min per 8-h workday) and 12 months (-45.4 [-64.6 to -26.2] min per 8-h workday). Significant intervention effects (all favoring intervention) were observed for standing, prolonged sitting, and usual sitting bout duration at work, as well as overall sitting and standing time, with no significant or meaningful effects observed for stepping. This workplace-delivered multicomponent intervention was successful at reducing workplace and overall daily sitting time in both the short term and the long term.

  10. Minimal Intensity Physical Activity (Standing and Walking) of Longer Duration Improves Insulin Action and Plasma Lipids More than Shorter Periods of Moderate to Vigorous Exercise (Cycling) in Sedentary Subjects When Energy Expenditure Is Comparable

    PubMed Central

    Duvivier, Bernard M. F. M.; Schaper, Nicolaas C.; Bremers, Michelle A.; van Crombrugge, Glenn; Menheere, Paul P. C. A.; Kars, Marleen; Savelberg, Hans H. C. M.

    2013-01-01

    Background Epidemiological studies suggest that excessive sitting time is associated with increased health risk, independent of the performance of exercise. We hypothesized that a daily bout of exercise cannot compensate the negative effects of inactivity during the rest of the day on insulin sensitivity and plasma lipids. Methodology/Principal Findings Eighteen healthy subjects, age 21±2 year, BMI 22.6±2.6 kgm−2 followed randomly three physical activity regimes for four days. Participants were instructed to sit 14 hr/day (sitting regime); to sit 13 hr/day and to substitute 1 hr of sitting with vigorous exercise 1 hr (exercise regime); to substitute 6 hrs sitting with 4 hr walking and 2 hr standing (minimal intensity physical activity (PA) regime). The sitting and exercise regime had comparable numbers of sitting hours; the exercise and minimal intensity PA regime had the same daily energy expenditure. PA was assessed continuously by an activity monitor (ActivPAL) and a diary. Measurements of insulin sensitivity (oral glucose tolerance test, OGTT) and plasma lipids were performed in the fasting state, the morning after the 4 days of each regime. In the sitting regime, daily energy expenditure was about 500 kcal lower than in both other regimes. Area under the curve for insulin during OGTT was significantly lower after the minimal intensity PA regime compared to both sitting and exercise regimes 6727.3±4329.4 vs 7752.0±3014.4 and 8320.4±5383.7 mU•min/ml, respectively. Triglycerides, non-HDL cholesterol and apolipoprotein B plasma levels improved significantly in the minimal intensity PA regime compared to sitting and showed non-significant trends for improvement compared to exercise. Conclusions One hour of daily physical exercise cannot compensate the negative effects of inactivity on insulin level and plasma lipids if the rest of the day is spent sitting. Reducing inactivity by increasing the time spent walking/standing is more effective than one hour of physical exercise, when energy expenditure is kept constant. PMID:23418444

  11. Status of the photomultiplier-based FlashCam camera for the Cherenkov Telescope Array

    NASA Astrophysics Data System (ADS)

    Pühlhofer, G.; Bauer, C.; Eisenkolb, F.; Florin, D.; Föhr, C.; Gadola, A.; Garrecht, F.; Hermann, G.; Jung, I.; Kalekin, O.; Kalkuhl, C.; Kasperek, J.; Kihm, T.; Koziol, J.; Lahmann, R.; Manalaysay, A.; Marszalek, A.; Rajda, P. J.; Reimer, O.; Romaszkan, W.; Rupinski, M.; Schanz, T.; Schwab, T.; Steiner, S.; Straumann, U.; Tenzer, C.; Vollhardt, A.; Weitzel, Q.; Winiarski, K.; Zietara, K.

    2014-07-01

    The FlashCam project is preparing a camera prototype around a fully digital FADC-based readout system, for the medium sized telescopes (MST) of the Cherenkov Telescope Array (CTA). The FlashCam design is the first fully digital readout system for Cherenkov cameras, based on commercial FADCs and FPGAs as key components for digitization and triggering, and a high performance camera server as back end. It provides the option to easily implement different types of trigger algorithms as well as digitization and readout scenarios using identical hardware, by simply changing the firmware on the FPGAs. The readout of the front end modules into the camera server is Ethernet-based using standard Ethernet switches and a custom, raw Ethernet protocol. In the current implementation of the system, data transfer and back end processing rates of 3.8 GB/s and 2.4 GB/s have been achieved, respectively. Together with the dead-time-free front end event buffering on the FPGAs, this permits the cameras to operate at trigger rates of up to several ten kHz. In the horizontal architecture of FlashCam, the photon detector plane (PDP), consisting of photon detectors, preamplifiers, high voltage-, control-, and monitoring systems, is a self-contained unit, mechanically detached from the front end modules. It interfaces to the digital readout system via analogue signal transmission. The horizontal integration of FlashCam is expected not only to be more cost efficient, it also allows PDPs with different types of photon detectors to be adapted to the FlashCam readout system. By now, a 144-pixel mini-camera" setup, fully equipped with photomultipliers, PDP electronics, and digitization/ trigger electronics, has been realized and extensively tested. Preparations for a full-scale, 1764 pixel camera mechanics and a cooling system are ongoing. The paper describes the status of the project.

  12. View Northward from Spirit's Winter Roost (False Color)

    NASA Technical Reports Server (NTRS)

    2006-01-01

    One part of the research program that NASA's Mars Exploration Rover Spirit is conducting while sitting at a favorable location for wintertime solar energy is the most detailed panorama yet taken on the surface of Mars. This view is a partial preliminary product from the continuing work on the full image, which will be called the 'McMurdo Panorama.'

    Spirit's panoramic camera (Pancam) began taking exposures for the McMurdo Panorama on the rover's 814th Martian day (April 18, 2006). The rover has accumulated more than 900 exposures for this panorama so far, through all of the Pancam mineralogy filters and using little or no image compression. Even with a tilt toward the winter sun, the amount of energy available daily is small, so the job will still take one to two more months to complete.

    This portion of the work in progress looks toward the north. 'Husband Hill,' which Spirit was climbing a year ago, is on the horizon near the center. 'Home Plate' is a between that hill and the rover's current position. Wheel tracks imprinted when Spirit drove south from Home Plate can be seen crossing the middle distance of the image from the center to the right.

    This view is presented in false color to emphasize differences among rock and soil materials. It combines exposures taken through three of the panoramic camera's filters, centered on wavelengths of 750 nanometers, 530 nanometers and 430 nanometers.

  13. Optomechanical System Development of the AWARE Gigapixel Scale Camera

    NASA Astrophysics Data System (ADS)

    Son, Hui S.

    Electronic focal plane arrays (FPA) such as CMOS and CCD sensors have dramatically improved to the point that digital cameras have essentially phased out film (except in very niche applications such as hobby photography and cinema). However, the traditional method of mating a single lens assembly to a single detector plane, as required for film cameras, is still the dominant design used in cameras today. The use of electronic sensors and their ability to capture digital signals that can be processed and manipulated post acquisition offers much more freedom of design at system levels and opens up many interesting possibilities for the next generation of computational imaging systems. The AWARE gigapixel scale camera is one such computational imaging system. By utilizing a multiscale optical design, in which a large aperture objective lens is mated with an array of smaller, well corrected relay lenses, we are able to build an optically simple system that is capable of capturing gigapixel scale images via post acquisition stitching of the individual pictures from the array. Properly shaping the array of digital cameras allows us to form an effectively continuous focal surface using off the shelf (OTS) flat sensor technology. This dissertation details developments and physical implementations of the AWARE system architecture. It illustrates the optomechanical design principles and system integration strategies we have developed through the course of the project by summarizing the results of the two design phases for AWARE: AWARE-2 and AWARE-10. These systems represent significant advancements in the pursuit of scalable, commercially viable snapshot gigapixel imaging systems and should serve as a foundation for future development of such systems.

  14. Similar metabolic response to lower- versus upper-body interval exercise or endurance exercise.

    PubMed

    Francois, Monique E; Graham, Matthew J; Parr, Evelyn B; Rehrer, Nancy J; Lucas, Samuel J E; Stavrianeas, Stasinos; Cotter, James D

    2017-03-01

    To compare energy use and substrate partitioning arising from repeated lower- versus upper-body sprints, or endurance exercise, across a 24-h period. Twelve untrained males (24±4 y) completed three trials in randomized order: (1) repeated sprints (five 30-s Wingate, 4.5-min recovery) on a cycle ergometer (SIT Legs ); (2) 50-min continuous cycling at 65% V̇O 2 max (END); (3) repeated sprints on an arm-crank ergometer (SIT Arms ). Respiratory gas exchange was assessed before and during exercise, and at eight points across 22h of recovery. Metabolic rate was elevated to greater extent in the first 8h after SIT Legs than SIT Arms (by 0.8±1.1kJ/min, p=0.03), and tended to be greater than END (by 0.7±1.3kJ/min, p=0.08). Total 24-h energy use (exercise+recovery) was equivalent between SIT Legs and END (p = 0.55), and SIT Legs and SIT Arms (p=0.13), but 24-h fat use was higher with SIT Legs than END (by 26±38g, p=0.04) and SIT Arms (by 27±43g, p=0.05), whereas carbohydrate use was higher with SIT Arms than SIT Legs (by 32±51g, p=0.05). Plasma volume-corrected post-exercise and fasting glucose and lipid concentrations were unchanged. Despite much lower energy use during five sprints than 50-min continuous exercise, 24-h energy use was not reliably different. However, (i) fat metabolism was greater after sprints, and (ii) carbohydrate metabolism was greater in the hours after sprints with arms than legs, while 24-h energy usage was comparable. Thus, sprints using arms or legs may be an important adjunct exercise mode for metabolic health. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Measurement properties and feasibility of clinical tests to assess sit-to-stand/stand-to-sit tasks in subjects with neurological disease: a systematic review

    PubMed Central

    Silva, Paula F. S.; Quintino, Ludmylla F.; Franco, Juliane; Faria, Christina D. C. M.

    2014-01-01

    Background Subjects with neurological disease (ND) usually show impaired performance during sit-to-stand and stand-to-sit tasks, with a consequent reduction in their mobility levels. Objective To determine the measurement properties and feasibility previously investigated for clinical tests that evaluate sit-to-stand and stand-to-sit in subjects with ND. Method A systematic literature review following the PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) protocol was performed. Systematic literature searches of databases (MEDLINE/SCIELO/LILACS/PEDro) were performed to identify relevant studies. In all studies, the following inclusion criteria were assessed: investigation of any measurement property or the feasibility of clinical tests that evaluate sit-to-stand and stand-to-sit tasks in subjects with ND published in any language through December 2012. The COSMIN checklist was used to evaluate the methodological quality of the included studies. Results Eleven studies were included. The measurement properties/feasibility were most commonly investigated for the five-repetition sit-to-stand test, which showed good test-retest reliability (Intraclass Correlation Coefficient:ICC=0.94-0.99) for subjects with stroke, cerebral palsy and dementia. The ICC values were higher for this test than for the number of repetitions in the 30-s test. The five-repetition sit-to-stand test also showed good inter/intra-rater reliabilities (ICC=0.97-0.99) for stroke and inter-rater reliability (ICC=0.99) for subjects with Parkinson disease and incomplete spinal cord injury. For this test, the criterion-related validity for subjects with stroke, cerebral palsy and incomplete spinal cord injury was, in general, moderate (correlation=0.40-0.77), and the feasibility and safety were good for subjects with Alzheimer's disease. Conclusions The five-repetition sit-to-stand test was used more often in subjects with ND, and most of the measurement properties were investigated and showed adequate results. PMID:24839043

  16. Determination of the swing technique characteristics and performance outcome relationship in golf driving for low handicap female golfers.

    PubMed

    Brown, Susan J; Nevill, Alan M; Monk, Stuart A; Otto, Steve R; Selbie, W Scott; Wallace, Eric S

    2011-11-01

    Previous studies on the kinematics of the golf swing have mainly focused on group analysis of male golfers of a wide ability range. In the present study, we investigated gross body kinematics using a novel method of analysis for golf research for a group of low handicap female golfers to provide an understanding of their swing mechanics in relation to performance. Data were collected for the drive swings of 16 golfers using a 12-camera three-dimensional motion capture system and a stereoscopic launch monitor. Analysis of covariance identified three covariates (increased pelvis-thorax differential at the top of the backswing, increased pelvis translation during the backswing, and a decrease in absolute backswing time) as determinants of the variance in clubhead speed (adjusted r (2) = 0.965, P < 0.05). A significant correlation was found between left-hand grip strength and clubhead speed (r = 0.54, P < 0.05) and between handicap and clubhead speed (r = -0.612, P < 0.05). Flexibility measures showed some correlation with clubhead speed; both sitting flexibility tests gave positive correlations (clockwise: r = 0.522, P < 0.05; counterclockwise: r = 0.711, P < 0.01). The results suggest that there is no common driver swing technique for optimal performance in low handicap female golfers, and therefore consideration should be given to individual swing characteristics in future studies.

  17. Data Acquisition System of Nobeyama MKID Camera

    NASA Astrophysics Data System (ADS)

    Nagai, M.; Hisamatsu, S.; Zhai, G.; Nitta, T.; Nakai, N.; Kuno, N.; Murayama, Y.; Hattori, S.; Mandal, P.; Sekimoto, Y.; Kiuchi, H.; Noguchi, T.; Matsuo, H.; Dominjon, A.; Sekiguchi, S.; Naruse, M.; Maekawa, J.; Minamidani, T.; Saito, M.

    2018-05-01

    We are developing a superconducting camera based on microwave kinetic inductance detectors (MKIDs) to observe 100-GHz continuum with the Nobeyama 45-m telescope. A data acquisition (DAQ) system for the camera has been designed to operate the MKIDs with the telescope. This system is required to connect the telescope control system (COSMOS) to the readout system of the MKIDs (MKID DAQ) which employs the frequency-sweeping probe scheme. The DAQ system is also required to record the reference signal of the beam switching for the demodulation by the analysis pipeline in order to suppress the sky fluctuation. The system has to be able to merge and save all data acquired both by the camera and by the telescope, including the cryostat temperature and pressure and the telescope pointing. A collection of software which implements these functions and works as a TCP/IP server on a workstation was developed. The server accepts commands and observation scripts from COSMOS and then issues commands to MKID DAQ to configure and start data acquisition. We made a commissioning of the MKID camera on the Nobeyama 45-m telescope and obtained successful scan signals of the atmosphere and of the Moon.

  18. Developing a multi-Kinect-system for monitoring in dairy cows: object recognition and surface analysis using wavelets.

    PubMed

    Salau, J; Haas, J H; Thaller, G; Leisen, M; Junge, W

    2016-09-01

    Camera-based systems in dairy cattle were intensively studied over the last years. Different from this study, single camera systems with a limited range of applications were presented, mostly using 2D cameras. This study presents current steps in the development of a camera system comprising multiple 3D cameras (six Microsoft Kinect cameras) for monitoring purposes in dairy cows. An early prototype was constructed, and alpha versions of software for recording, synchronizing, sorting and segmenting images and transforming the 3D data in a joint coordinate system have already been implemented. This study introduced the application of two-dimensional wavelet transforms as method for object recognition and surface analyses. The method was explained in detail, and four differently shaped wavelets were tested with respect to their reconstruction error concerning Kinect recorded depth maps from different camera positions. The images' high frequency parts reconstructed from wavelet decompositions using the haar and the biorthogonal 1.5 wavelet were statistically analyzed with regard to the effects of image fore- or background and of cows' or persons' surface. Furthermore, binary classifiers based on the local high frequencies have been implemented to decide whether a pixel belongs to the image foreground and if it was located on a cow or a person. Classifiers distinguishing between image regions showed high (⩾0.8) values of Area Under reciever operation characteristic Curve (AUC). The classifications due to species showed maximal AUC values of 0.69.

  19. Inspecting rapidly moving surfaces for small defects using CNN cameras

    NASA Astrophysics Data System (ADS)

    Blug, Andreas; Carl, Daniel; Höfler, Heinrich

    2013-04-01

    A continuous increase in production speed and manufacturing precision raises a demand for the automated detection of small image features on rapidly moving surfaces. An example are wire drawing processes where kilometers of cylindrical metal surfaces moving with 10 m/s have to be inspected for defects such as scratches, dents, grooves, or chatter marks with a lateral size of 100 μm in real time. Up to now, complex eddy current systems are used for quality control instead of line cameras, because the ratio between lateral feature size and surface speed is limited by the data transport between camera and computer. This bottleneck is avoided by "cellular neural network" (CNN) cameras which enable image processing directly on the camera chip. This article reports results achieved with a demonstrator based on this novel analogue camera - computer system. The results show that computational speed and accuracy of the analogue computer system are sufficient to detect and discriminate the different types of defects. Area images with 176 x 144 pixels are acquired and evaluated in real time with frame rates of 4 to 10 kHz - depending on the number of defects to be detected. These frame rates correspond to equivalent line rates on line cameras between 360 and 880 kHz, a number far beyond the available features. Using the relation between lateral feature size and surface speed as a figure of merit, the CNN based system outperforms conventional image processing systems by an order of magnitude.

  20. In-camera video-stream processing for bandwidth reduction in web inspection

    NASA Astrophysics Data System (ADS)

    Jullien, Graham A.; Li, QiuPing; Hajimowlana, S. Hossain; Morvay, J.; Conflitti, D.; Roberts, James W.; Doody, Brian C.

    1996-02-01

    Automated machine vision systems are now widely used for industrial inspection tasks where video-stream data information is taken in by the camera and then sent out to the inspection system for future processing. In this paper we describe a prototype system for on-line programming of arbitrary real-time video data stream bandwidth reduction algorithms; the output of the camera only contains information that has to be further processed by a host computer. The processing system is built into a DALSA CCD camera and uses a microcontroller interface to download bit-stream data to a XILINXTM FPGA. The FPGA is directly connected to the video data-stream and outputs data to a low bandwidth output bus. The camera communicates to a host computer via an RS-232 link to the microcontroller. Static memory is used to both generate a FIFO interface for buffering defect burst data, and for off-line examination of defect detection data. In addition to providing arbitrary FPGA architectures, the internal program of the microcontroller can also be changed via the host computer and a ROM monitor. This paper describes a prototype system board, mounted inside a DALSA camera, and discusses some of the algorithms currently being implemented for web inspection applications.

  1. Senile gluteal dermatosis: a clinical study of 137 cases.

    PubMed

    Liu, Han-Nan; Wang, Wen-Jen; Chen, Chih-Chiang; Lee, Ding-Dar; Chang, Yun-Ting

    2014-01-01

    Senile gluteal dermatosis (SGD) is a common genital dermatosis but has gained little attention before. A large-scale clinical study of this disease is lacking. We examined 162 consecutive outpatients with gluteal skin diseases of different causes. Fourteen skin biopsies were performed. Patient's age, gender, body mass index (BMI), way of sitting or lying, treatment response, and underlying systemic diseases were recorded. About 137 (85%) patients could be defined as SGD. These patients, with a mean age of 79.4 ± 40.7 years and a mean BMI of 21.7 ± 10.8, presented with either partial (n = 43, 31%) or full-blown (n = 94, 69%) SGD lesions characterized by the sign of so-called "three corners of a triangle": brownish plaques on the gluteal cleft and each side of the buttocks. Male/female ratio was 130/7. Itching or pain of varying intensity was reported by 50 patients (36%) and 14 patients (10%), respectively. Eighty-six patients (53%) presented with horizontal hyperkeratotic ridges, a characteristic sign of SGD. Most patients spent most of the day sitting but reported no special way of sitting or lying. More than half of patients with SGD claimed no response to topical steroids and/or keratolytics. In comparison with patients with SGD, SGD-free patients were younger (61.3 ± 36 years, P = 0.0005) and heavier (BMI 26.2 ± 15.6, P < 0.0001) but showed no significant difference in the frequency of underlying systemic diseases. SGD is a common dermatosis, mostly affecting the thinner elderly. Friction, pressures and long hours sitting seemed to be important factors to trigger this dermatosis. © 2013 The International Society of Dermatology.

  2. Efficacy of combination treatment with anti-IgE plus specific immunotherapy in polysensitized children and adolescents with seasonal allergic rhinitis.

    PubMed

    Kuehr, Joachim; Brauburger, Jens; Zielen, Stefan; Schauer, Uwe; Kamin, Wolfgang; Von Berg, Andrea; Leupold, Wolfgang; Bergmann, Karl-Christian; Rolinck-Werninghaus, Claudia; Gräve, Michael; Hultsch, Thomas; Wahn, Ulrich

    2002-02-01

    Specific immunotherapy (SIT) and treatment with monoclonal anti-IgE antibody have complementary modes of action. The purpose of this study was to determine whether combined therapy could provide better efficacy than either treatment alone. We conducted a randomized, double-blinded trial to assess the efficacy and safety of subcutaneously administered anti-IgE (omalizumab) or placebo in children and adolescents with seasonal allergic rhinitis in both a birch pollen season and a grass pollen season (sequential seasons together lasting an average of 84 days). There were 4 treatment arms. Each subject was started on SIT-birch or SIT-grass, and anti-IgE or placebo was started before and maintained during the anticipated pollen seasons (a total of 24 weeks). The primary efficacy variable was symptom load, the sum of daily symptom severity score plus rescue medication use. A total of 221 subjects (intent-to-treat population) aged 6 to 17 years were analyzed for efficacy. Combination therapy reduced symptom load over the 2 pollen seasons by 48% (P <.001) over SIT alone. When analyzed separately by season, the 2 groups receiving unrelated SIT were considered placebo controls. In the grass season, symptom loads were as follows: unrelated (birch) SIT + placebo, 0.89 (reference value); unrelated (birch) SIT + anti-IgE, 0.49 (-45%); SIT-grass + placebo, 0.61 (-32%); SIT-grass + anti-IgE, 0.26 (-71%). Anti-IgE therapy conferred a protective effect independent of the type of allergen. Additional clinical benefit was demonstrated in both pollen seasons, whether there was coverage by SIT or not. This combination might prove useful for the treatment of allergic rhinitis, particularly for polysensitized patients.

  3. Reliability and Validity of the Hip Stability Isometric Test (HipSIT): A New Method to Assess Hip Posterolateral Muscle Strength.

    PubMed

    Almeida, Gabriel Peixoto Leão; das Neves Rodrigues, Helena Larissa; de Freitas, Bruno Wesley; de Paula Lima, Pedro Olavo

    2017-12-01

    Study Design Cross-sectional study. Background The Hip Stability Isometric Test (HipSIT) evaluates the strength of the hip posterolateral stabilizers in a position that favors greater activation of the gluteus maximus and gluteus medius and lower activation of the tensor fascia lata. Objectives To check the validity and reliability of the HipSIT and to evaluate the HipSIT in women with patellofemoral pain (PFP). Methods The HipSIT was evaluated with a handheld dynamometer. During testing, the participants were sidelying, with their legs positioned at 45° of hip flexion and 90° of knee flexion. Participants were instructed to raise the knee of the upper leg while keeping the upper and lower heels in contact. To establish reliability and validity, 49 women were tested with the HipSIT by 2 different evaluators on day 1, and then again 7 days later. The strength of the hip extensors, abductors, and external rotators was also evaluated. Twenty women with unilateral PFP were also evaluated. Results The HipSIT has excellent intrarater and interrater reliability. The standard error of measurement was 0.01 kgf/kg, and the minimal detectable change was 0.036 kgf/kg. The HipSIT showed good validity in isolated hip abduction, external rotation, and extension (P<.01). Women with PFP showed a 10% deficit in the HipSIT results for the symptomatic limb (P = .01). Conclusion The HipSIT showed excellent interrater and intrarater reliability, moderate to good validity in women, and was able to identify strength deficits in women with PFP. J Orthop Sports Phys Ther 2017;47(12):906-913. Epub 9 Oct 2017. doi:10.2519/jospt.2017.7274.

  4. Acute and chronic effects of sprint interval exercise on postprandial lipemia in women at-risk for the metabolic syndrome.

    PubMed

    Freese, Eric C; Gist, Nicholas H; Acitelli, Rachelle M; McConnell, Whitni J; Beck, Catherine D; Hausman, Dorothy B; Murrow, Jonathan R; Cureton, Kirk J; Evans, Ellen M

    2015-04-01

    Individuals diagnosed with the metabolic syndrome (MetS) exhibit elevated postprandial lipemia (PPL). The aims of this investigation were to determine 1) if an acute bout of sprint interval training (SIT) attenuates PPL; and 2) if the attenuation of PPL following 6 wk of SIT is magnified compared with a single session of SIT prior to training in women at-risk for MetS (n = 45; 30-65 yr). Women were randomized to SIT (n = 22) or a nonexercise control (n = 23; CON) for 6 wk. Postprandial responses to a high-fat meal challenge (HFMC) were assessed in the CON group before (B-HFMC) and after (Post-HFMC) without prior exercise and in the SIT group at baseline (B-HFMC) without prior exercise, after an acute bout of SIT (four 30-s all-out sprints with 4-min recovery) prior to (Pre-HFMC), and after the 6-wk intervention (Post-HFMC). Responses to the HFMC were assessed by collecting venous blood samples in the fasted state and at 0, 30, 60, 120, and 180 min postprandial. Compared with baseline, an acute bout of SIT before (Pre-HFMC) and after the 6-wk intervention (Post-HFMC) significantly attenuated fasted TG (P < 0.05; 16.6% and 12.3%, respectively) and postprandial area under the curve (13.1% and 9.7%, respectively; tAUC) TG responses. There was no difference in fasted or tAUC TG responses between Pre-HFMC and Post-HFMC. SIT is an effective mode of exercise to reduce fasted and postprandial TG concentrations in women at-risk for MetS. Six weeks of SIT does not magnify the attenuation of PPL in response to a single session of SIT. Copyright © 2015 the American Physiological Society.

  5. Association between various sedentary behaviours and all-cause, cardiovascular disease and cancer mortality: the Multiethnic Cohort Study

    PubMed Central

    Kim, Yeonju; Wilkens, Lynne R; Park, Song-Yi; Goodman, Marc T; Monroe, Kristine R; Kolonel, Laurence N

    2013-01-01

    Background It has been proposed that time spent sitting increases all-cause mortality, but evidence to support this hypothesis, especially the relative effects of various sitting activities alone or in combination, is very limited. Methods The association between various sedentary behaviours (time spent: sitting watching television (TV); in other leisure activities; in a car/bus; at work; and at meals) and mortality (all-cause and cause-specific) was examined in the Multiethnic Cohort Study, which included 61 395 men and 73 201 women aged 45–75 years among five racial/ethnic groups (African American, Latino, Japanese American, Native Hawaiian and White) from Hawaii and Los Angeles, USA. Results Median follow-up was 13.7 years and 19 143 deaths were recorded. Total daily sitting was not associated with mortality in men, whereas in women the longest sitting duration (≥10 h/day vs <5 h/day) was associated with increased all-cause (11%) and cardiovascular (19%) mortality. Multivariate hazard ratios (HR) for ≥5 h/day vs <1 h/day of sitting watching TV were 1.19 in men (95% confidence interval (CI) 1.10–1.29) and 1.32 in women (95% CI 1.21–1.44) for all-cause mortality. This association was consistent across four racial/ethnic groups, but was not seen in Japanese Americans. Sitting watching TV was associated with an increased risk for cardiovascular mortality, but not for cancer mortality. Time spent sitting in a car/bus and at work was not related to mortality. Conclusions Leisure time spent sitting, particularly watching television, may increase overall and cardiovascular mortality. Sitting at work or during transportation was not related to mortality. PMID:24062293

  6. Utilizing ISS Camera Systems for Scientific Analysis of Lightning Characteristics and Comparison with ISS-LIS and GLM

    NASA Technical Reports Server (NTRS)

    Schultz, Christopher J.; Lang, Timothy J.; Leake, Skye; Runco, Mario, Jr.; Blakeslee, Richard J.

    2017-01-01

    Video and still frame images from cameras aboard the International Space Station (ISS) are used to inspire, educate, and provide a unique vantage point from low-Earth orbit that is second to none; however, these cameras have overlooked capabilities for contributing to scientific analysis of the Earth and near-space environment. The goal of this project is to study how geo referenced video/images from available ISS camera systems can be useful for scientific analysis, using lightning properties as a demonstration.

  7. Workplace interventions for reducing sitting at work.

    PubMed

    Shrestha, Nipun; Ijaz, Sharea; Kukkonen-Harjula, Katriina T; Kumar, Suresh; Nwankwo, Chukwudi P

    2015-01-26

    The number of people working whilst seated at a desk keeps increasing worldwide. As sitting increases, occupational physical strain declines at the same time. This has contributed to increases in cardiovascular disease, obesity and diabetes. Therefore, reducing and breaking up the time that people spend sitting while at work is important for health. To evaluate the effects of workplace interventions to reduce sitting at work compared to no intervention or alternative interventions. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, CINAHL, OSH UPDATE, PsycINFO, Clinical trials.gov and the World Health Organization (WHO) search trial portal up to 14 February, 2014. We also searched reference lists of articles and contacted authors. We included randomised controlled trials (RCT), cluster-randomised controlled trials (cRCTs), and quasi-randomised controlled trials of interventions to reduce sitting at work. For changes of workplace arrangements, we also included controlled before-and-after studies (CBAs) with a concurrent control group. The primary outcome was time spent sitting at work per day, either self-reported or objectively measured by means of an accelerometer coupled with an inclinometer. We considered energy expenditure, duration and number of sitting episodes lasting 30 minutes or more, work productivity and adverse events as secondary outcomes. Two review authors independently screened titles, abstracts and full-text articles for study eligibility. Two review authors independently extracted data and assessed risk of bias. We contacted authors for additional data where required. We included eight studies, four RCTs, three CBAs and one cRCT, with a total of 1125 participants. The studies evaluated physical workplace changes (three studies), policy changes (one study) and information and counselling (four studies). No studies investigated the effect of treadmill desks, stepping devices, periodic breaks or standing or walking meetings. All the studies were at high risk of bias. The quality of the evidence was very low to low. Half of the studies were from Australia and the other half from Europe, with none from low- or middle-income countries. Physical workplace changesWe found very low quality evidence that sit-stand desks with or without additional counselling reduced sitting time at work per workday at one week follow-up (MD -143 minutes (95% CI -184 to -102, one study, 31 participants) and at three months' follow-up (MD - 113 minutes, 95% CI -143 to -84, two studies, 61 participants) compared to no intervention. Total sitting time during the whole day decreased also with sit-stand desks compared to no intervention (MD -78 minutes, 95% CI -125 to -30, one study, 31 participants) as did the duration of sitting episodes lasting 30 minutes or more (MD -52 minutes, 95% CI -79 to -26, two studies, 74 participants). Sit-stand desks did not have a considerable effect on work performance and had an inconsistent effect on musculoskeletal symptoms and sick leave. Policy changesWalking strategies had no considerable effect on sitting at work (MD -16 minutes, 95% CI -54 to 23, one study, 179 participants, low quality evidence). Information and counsellingGuideline-based counselling by occupational physicians reduced sitting time at work (MD -28 minutes, 95% CI -54 to -2, one study, 396 participants, low quality evidence). There was no considerable effect on reduction in total sitting time during the whole day.Mindfulness training induced a non-significant reduction in workplace sitting time (MD -2 minutes, 95% CI -22 to 18) at six months' follow-up and at 12 months' follow-up (MD -16 minutes, 95% CI -45 to 12, one study, 257 participants, low quality evidence).There was an inconsistent effect of computer prompting on sitting time at work. One study found no considerable effect on sitting at work (MD -18 minutes, 95% CI -53 to 17, 28 participants, low quality evidence) at 10 days' follow-up, while another study reported a significant reduction in sitting at work (MD -55 minutes, 95% CI -96 to -14, 34 participants, low quality evidence) at 13 weeks' follow-up. Computer prompting software also led to a non-significant increase in energy expenditure at work (MD 278 calories/workday, 95% CI 0 to 556, one study, 34 participants, low quality evidence) at 13 weeks' follow-up. At present there is very low quality evidence that sit-stand desks can reduce sitting time at work, but the effects of policy changes and information and counselling are inconsistent. There is a need for high quality cluster-randomised trials to assess the effects of different types of interventions on objectively measured sitting time. There are many ongoing trials that might change these conclusions in the near future.

  8. Evaluation of multispectral plenoptic camera

    NASA Astrophysics Data System (ADS)

    Meng, Lingfei; Sun, Ting; Kosoglow, Rich; Berkner, Kathrin

    2013-01-01

    Plenoptic cameras enable capture of a 4D lightfield, allowing digital refocusing and depth estimation from data captured with a compact portable camera. Whereas most of the work on plenoptic camera design has been based a simplistic geometric-optics-based characterization of the optical path only, little work has been done of optimizing end-to-end system performance for a specific application. Such design optimization requires design tools that need to include careful parameterization of main lens elements, as well as microlens array and sensor characteristics. In this paper we are interested in evaluating the performance of a multispectral plenoptic camera, i.e. a camera with spectral filters inserted into the aperture plane of the main lens. Such a camera enables single-snapshot spectral data acquisition.1-3 We first describe in detail an end-to-end imaging system model for a spectrally coded plenoptic camera that we briefly introduced in.4 Different performance metrics are defined to evaluate the spectral reconstruction quality. We then present a prototype which is developed based on a modified DSLR camera containing a lenslet array on the sensor and a filter array in the main lens. Finally we evaluate the spectral reconstruction performance of a spectral plenoptic camera based on both simulation and measurements obtained from the prototype.

  9. Plate refractive camera model and its applications

    NASA Astrophysics Data System (ADS)

    Huang, Longxiang; Zhao, Xu; Cai, Shen; Liu, Yuncai

    2017-03-01

    In real applications, a pinhole camera capturing objects through a planar parallel transparent plate is frequently employed. Due to the refractive effects of the plate, such an imaging system does not comply with the conventional pinhole camera model. Although the system is ubiquitous, it has not been thoroughly studied. This paper aims at presenting a simple virtual camera model, called a plate refractive camera model, which has a form similar to a pinhole camera model and can efficiently model refractions through a plate. The key idea is to employ a pixel-wise viewpoint concept to encode the refraction effects into a pixel-wise pinhole camera model. The proposed camera model realizes an efficient forward projection computation method and has some advantages in applications. First, the model can help to compute the caustic surface to represent the changes of the camera viewpoints. Second, the model has strengths in analyzing and rectifying the image caustic distortion caused by the plate refraction effects. Third, the model can be used to calibrate the camera's intrinsic parameters without removing the plate. Last but not least, the model contributes to putting forward the plate refractive triangulation methods in order to solve the plate refractive triangulation problem easily in multiviews. We verify our theory in both synthetic and real experiments.

  10. A multiple camera tongue switch for a child with severe spastic quadriplegic cerebral palsy.

    PubMed

    Leung, Brian; Chau, Tom

    2010-01-01

    The present study proposed a video-based access technology that facilitated a non-contact tongue protrusion access modality for a 7-year-old boy with severe spastic quadriplegic cerebral palsy (GMFCS level 5). The proposed system featured a centre camera and two peripheral cameras to extend coverage of the frontal face view of this user for longer durations. The child participated in a descriptive case study. The participant underwent 3 months of tongue protrusion training while the multiple camera tongue switch prototype was being prepared. Later, the participant was brought back for five experiment sessions where he worked on a single-switch picture matching activity, using the multiple camera tongue switch prototype in a controlled environment. The multiple camera tongue switch achieved an average sensitivity of 82% and specificity of 80%. In three of the experiment sessions, the peripheral cameras were associated with most of the true positive switch activations. These activations would have been missed by a centre-camera-only setup. The study demonstrated proof-of-concept of a non-contact tongue access modality implemented by a video-based system involving three cameras and colour video processing.

  11. Design and Development of Multi-Purpose CCD Camera System with Thermoelectric Cooling: Hardware

    NASA Astrophysics Data System (ADS)

    Kang, Y.-W.; Byun, Y. I.; Rhee, J. H.; Oh, S. H.; Kim, D. K.

    2007-12-01

    We designed and developed a multi-purpose CCD camera system for three kinds of CCDs; KAF-0401E(768×512), KAF-1602E(1536×1024), KAF-3200E(2184×1472) made by KODAK Co.. The system supports fast USB port as well as parallel port for data I/O and control signal. The packing is based on two stage circuit boards for size reduction and contains built-in filter wheel. Basic hardware components include clock pattern circuit, A/D conversion circuit, CCD data flow control circuit, and CCD temperature control unit. The CCD temperature can be controlled with accuracy of approximately 0.4° C in the max. range of temperature, Δ 33° C. This CCD camera system has with readout noise 6 e^{-}, and system gain 5 e^{-}/ADU. A total of 10 CCD camera systems were produced and our tests show that all of them show passable performance.

  12. Inexpensive camera systems for detecting martens, fishers, and other animals: guidelines for use and standardization.

    Treesearch

    Lawrence L.C. Jones; Martin G. Raphael

    1993-01-01

    Inexpensive camera systems have been successfully used to detect the occurrence of martens, fishers, and other wildlife species. The use of cameras is becoming widespread, and we give suggestions for standardizing techniques so that comparisons of data can occur across the geographic range of the target species. Details are given on equipment needs, setting up the...

  13. Projector-Camera Systems for Immersive Training

    DTIC Science & Technology

    2006-01-01

    average to a sequence of 100 captured distortion corrected images. The OpenCV library [ OpenCV ] was used for camera calibration. To correct for...rendering application [Treskunov, Pair, and Swartout, 2004]. It was transposed to take into account different matrix conventions between OpenCV and...Screen Imperfections. Proc. Workshop on Projector-Camera Systems (PROCAMS), Nice, France, IEEE. OpenCV : Open Source Computer Vision. [Available

  14. Imagers for digital still photography

    NASA Astrophysics Data System (ADS)

    Bosiers, Jan; Dillen, Bart; Draijer, Cees; Manoury, Erik-Jan; Meessen, Louis; Peters, Inge

    2006-04-01

    This paper gives an overview of the requirements for, and current state-of-the-art of, CCD and CMOS imagers for use in digital still photography. Four market segments will be reviewed: mobile imaging, consumer "point-and-shoot cameras", consumer digital SLR cameras and high-end professional camera systems. The paper will also present some challenges and innovations with respect to packaging, testing, and system integration.

  15. Image Mosaicking Approach for a Double-Camera System in the GaoFen2 Optical Remote Sensing Satellite Based on the Big Virtual Camera.

    PubMed

    Cheng, Yufeng; Jin, Shuying; Wang, Mi; Zhu, Ying; Dong, Zhipeng

    2017-06-20

    The linear array push broom imaging mode is widely used for high resolution optical satellites (HROS). Using double-cameras attached by a high-rigidity support along with push broom imaging is one method to enlarge the field of view while ensuring high resolution. High accuracy image mosaicking is the key factor of the geometrical quality of complete stitched satellite imagery. This paper proposes a high accuracy image mosaicking approach based on the big virtual camera (BVC) in the double-camera system on the GaoFen2 optical remote sensing satellite (GF2). A big virtual camera can be built according to the rigorous imaging model of a single camera; then, each single image strip obtained by each TDI-CCD detector can be re-projected to the virtual detector of the big virtual camera coordinate system using forward-projection and backward-projection to obtain the corresponding single virtual image. After an on-orbit calibration and relative orientation, the complete final virtual image can be obtained by stitching the single virtual images together based on their coordinate information on the big virtual detector image plane. The paper subtly uses the concept of the big virtual camera to obtain a stitched image and the corresponding high accuracy rational function model (RFM) for concurrent post processing. Experiments verified that the proposed method can achieve seamless mosaicking while maintaining the geometric accuracy.

  16. Exploring the imaging properties of thin lenses for cryogenic infrared cameras

    NASA Astrophysics Data System (ADS)

    Druart, Guillaume; Verdet, Sebastien; Guerineau, Nicolas; Magli, Serge; Chambon, Mathieu; Grulois, Tatiana; Matallah, Noura

    2016-05-01

    Designing a cryogenic camera is a good strategy to miniaturize and simplify an infrared camera using a cooled detector. Indeed, the integration of optics inside the cold shield allows to simply athermalize the design, guarantees a cold pupil and releases the constraint on having a high back focal length for small focal length systems. By this way, cameras made of a single lens or two lenses are viable systems with good optical features and a good stability in image correction. However it involves a relatively significant additional optical mass inside the dewar and thus increases the cool down time of the camera. ONERA is currently exploring a minimalist strategy consisting in giving an imaging function to thin optical plates that are found in conventional dewars. By this way, we could make a cryogenic camera that has the same cool down time as a traditional dewar without an imagery function. Two examples will be presented: the first one is a camera using a dual-band infrared detector made of a lens outside the dewar and a lens inside the cold shield, the later having the main optical power of the system. We were able to design a cold plano-convex lens with a thickness lower than 1mm. The second example is an evolution of a former cryogenic camera called SOIE. We replaced the cold meniscus by a plano-convex Fresnel lens with a decrease of the optical thermal mass of 66%. The performances of both cameras will be compared.

  17. Line-Based Registration of Panoramic Images and LiDAR Point Clouds for Mobile Mapping.

    PubMed

    Cui, Tingting; Ji, Shunping; Shan, Jie; Gong, Jianya; Liu, Kejian

    2016-12-31

    For multi-sensor integrated systems, such as the mobile mapping system (MMS), data fusion at sensor-level, i.e., the 2D-3D registration between an optical camera and LiDAR, is a prerequisite for higher level fusion and further applications. This paper proposes a line-based registration method for panoramic images and a LiDAR point cloud collected by a MMS. We first introduce the system configuration and specification, including the coordinate systems of the MMS, the 3D LiDAR scanners, and the two panoramic camera models. We then establish the line-based transformation model for the panoramic camera. Finally, the proposed registration method is evaluated for two types of camera models by visual inspection and quantitative comparison. The results demonstrate that the line-based registration method can significantly improve the alignment of the panoramic image and the LiDAR datasets under either the ideal spherical or the rigorous panoramic camera model, with the latter being more reliable.

  18. Line-Based Registration of Panoramic Images and LiDAR Point Clouds for Mobile Mapping

    PubMed Central

    Cui, Tingting; Ji, Shunping; Shan, Jie; Gong, Jianya; Liu, Kejian

    2016-01-01

    For multi-sensor integrated systems, such as the mobile mapping system (MMS), data fusion at sensor-level, i.e., the 2D-3D registration between an optical camera and LiDAR, is a prerequisite for higher level fusion and further applications. This paper proposes a line-based registration method for panoramic images and a LiDAR point cloud collected by a MMS. We first introduce the system configuration and specification, including the coordinate systems of the MMS, the 3D LiDAR scanners, and the two panoramic camera models. We then establish the line-based transformation model for the panoramic camera. Finally, the proposed registration method is evaluated for two types of camera models by visual inspection and quantitative comparison. The results demonstrate that the line-based registration method can significantly improve the alignment of the panoramic image and the LiDAR datasets under either the ideal spherical or the rigorous panoramic camera model, with the latter being more reliable. PMID:28042855

  19. Design and Implementation of a Novel Portable 360° Stereo Camera System with Low-Cost Action Cameras

    NASA Astrophysics Data System (ADS)

    Holdener, D.; Nebiker, S.; Blaser, S.

    2017-11-01

    The demand for capturing indoor spaces is rising with the digitalization trend in the construction industry. An efficient solution for measuring challenging indoor environments is mobile mapping. Image-based systems with 360° panoramic coverage allow a rapid data acquisition and can be processed to georeferenced 3D images hosted in cloud-based 3D geoinformation services. For the multiview stereo camera system presented in this paper, a 360° coverage is achieved with a layout consisting of five horizontal stereo image pairs in a circular arrangement. The design is implemented as a low-cost solution based on a 3D printed camera rig and action cameras with fisheye lenses. The fisheye stereo system is successfully calibrated with accuracies sufficient for the applied measurement task. A comparison of 3D distances with reference data delivers maximal deviations of 3 cm on typical distances in indoor space of 2-8 m. Also the automatic computation of coloured point clouds from the stereo pairs is demonstrated.

  20. A single camera photogrammetry system for multi-angle fast localization of EEG electrodes.

    PubMed

    Qian, Shuo; Sheng, Yang

    2011-11-01

    Photogrammetry has become an effective method for the determination of electroencephalography (EEG) electrode positions in three dimensions (3D). Capturing multi-angle images of the electrodes on the head is a fundamental objective in the design of photogrammetry system for EEG localization. Methods in previous studies are all based on the use of either a rotating camera or multiple cameras, which are time-consuming or not cost-effective. This study aims to present a novel photogrammetry system that can realize simultaneous acquisition of multi-angle head images in a single camera position. Aligning two planar mirrors with the angle of 51.4°, seven views of the head with 25 electrodes are captured simultaneously by the digital camera placed in front of them. A complete set of algorithms for electrode recognition, matching, and 3D reconstruction is developed. It is found that the elapsed time of the whole localization procedure is about 3 min, and camera calibration computation takes about 1 min, after the measurement of calibration points. The positioning accuracy with the maximum error of 1.19 mm is acceptable. Experimental results demonstrate that the proposed system provides a fast and cost-effective method for the EEG positioning.

Top