SU-E-I-68: Practical Considerations On Implementation of the Image Gently Pediatric CT Protocols
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, J; Adams, C; Lumby, C
Purpose: One limitation associated with the Image Gently pediatric CT protocols is practical implementation of the recommended manual techniques. Inconsistency as a result of different practice is a possibility among technologist. An additional concern is the added risk of data error that would result in over or underexposure. The Automatic Exposure Control (AEC) features automatically reduce radiation for children. However, they do not work efficiently for the patients of very small size and relative large size. This study aims to implement the Image Gently pediatric CT protocols in the practical setting while maintaining the use of AEC features for pediatricmore » patients of varying size. Methods: Anthropomorphological abdomen phantoms were scanned in a CT scanner using the Image Gently pediatric protocols, the AEC technique with a fixed adult baseline, and automatic protocols with various baselines. The baselines were adjusted corresponding to patient age, weight and posterioranterior thickness to match the Image Gently pediatric CT manual techniques. CTDIvol was recorded for each examination. Image noise was measured and recorded for image quality comparison. Clinical images were evaluated by pediatric radiologists. Results: By adjusting vendor default baselines used in the automatic techniques, radiation dose and image quality can match those of the Image Gently manual techniques. In practice, this can be achieved by dividing pediatric patients into three major groups for technologist reference: infant, small child, and large child. Further division can be done but will increase the number of CT protocols. For each group, AEC can efficiently adjust acquisition techniques for children. This implementation significantly overcomes the limitation of the Image Gently manual techniques. Conclusion: Considering the effectiveness in clinical practice, Image Gently Pediatric CT protocols can be implemented in accordance with AEC techniques, with adjusted baselines, to achieve the goal of providing the most appropriate radiation dose for pediatric patients of varying sizes.« less
Lang, Dean H; Sharkey, Neil A; Lionikas, Arimantas; Mack, Holly A; Larsson, Lars; Vogler, George P; Vandenbergh, David J; Blizard, David A; Stout, Joseph T; Stitt, Joseph P; McClearn, Gerald E
2005-05-01
The aim of this study was to compare three methods of adjusting skeletal data for body size and examine their use in QTL analyses. It was found that dividing skeletal phenotypes by body mass index induced erroneous QTL results. The preferred method of body size adjustment was multiple regression. Many skeletal studies have reported strong correlations between phenotypes for muscle, bone, and body size, and these correlations add to the difficulty in identifying genetic influence on skeletal traits that are not mediated through overall body size. Quantitative trait loci (QTL) identified for skeletal phenotypes often map to the same chromosome regions as QTLs for body size. The actions of a QTL identified as influencing BMD could therefore be mediated through the generalized actions of growth on body size or muscle mass. Three methods of adjusting skeletal phenotypes to body size were performed on morphologic, structural, and compositional measurements of the femur and tibia in 200-day-old C57BL/6J x DBA/2 (BXD) second generation (F(2)) mice (n = 400). A common method of removing the size effect has been through the use of ratios. This technique and two alternative techniques using simple and multiple regression were performed on muscle and skeletal data before QTL analyses, and the differences in QTL results were examined. The use of ratios to remove the size effect was shown to increase the size effect by inducing spurious correlations, thereby leading to inaccurate QTL results. Adjustments for body size using multiple regression eliminated these problems. Multiple regression should be used to remove the variance of co-factors related to skeletal phenotypes to allow for the study of genetic influence independent of correlated phenotypes. However, to better understand the genetic influence, adjusted and unadjusted skeletal QTL results should be compared. Additional insight can be gained by observing the difference in LOD score between the adjusted and nonadjusted phenotypes. Identifying QTLs that exert their effects on skeletal phenotypes through body size-related pathways as well as those having a more direct and independent influence on bone are equally important in deciphering the complex physiologic pathways responsible for the maintenance of bone health.
Bernstein, Joshua G. W.; Summers, Van; Iyer, Nandini; Brungart, Douglas S.
2012-01-01
Adaptive signal-to-noise ratio (SNR) tracking is often used to measure speech reception in noise. Because SNR varies with performance using this method, data interpretation can be confounded when measuring an SNR-dependent effect such as the fluctuating-masker benefit (FMB) (the intelligibility improvement afforded by brief dips in the masker level). One way to overcome this confound, and allow FMB comparisons across listener groups with different stationary-noise performance, is to adjust the response set size to equalize performance across groups at a fixed SNR. However, this technique is only valid under the assumption that changes in set size have the same effect on percentage-correct performance for different masker types. This assumption was tested by measuring nonsense-syllable identification for normal-hearing listeners as a function of SNR, set size and masker (stationary noise, 4- and 32-Hz modulated noise and an interfering talker). Set-size adjustment had the same impact on performance scores for all maskers, confirming the independence of FMB (at matched SNRs) and set size. These results, along with those of a second experiment evaluating an adaptive set-size algorithm to adjust performance levels, establish set size as an efficient and effective tool to adjust baseline performance when comparing effects of masker fluctuations between listener groups. PMID:23039460
McCrea, C; Neil, W J; Flanigan, J W; Summerfield, A B
1988-08-01
In this study a new modified videosystem, designed for measuring body-image, was evaluated alongside the major size-estimation measure, namely, the visual size-estimation apparatus. The advantages afforded by a videosystem which allows independent adjustment of size and height/width proportions were highlighted, and its validity and reliability were examined, based on estimates made by obese, normal weight, and pregnant groups.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arbique, G; Anderson, J; Guild, J
Purpose: The National Lung Screening Trial mandated manual low dose CT technique factors, where up to a doubling of radiation output could be used over a regular to large patient size range. Recent guidance from the AAPM and ACR for lung cancer CT screening recommends radiation output adjustment for patient size either through AEC or a manual technique chart. This study evaluated the use of AEC for output control and dose reduction. Methods: The study was performed on a multidetector helical CT scanner (Aquillion ONE, Toshiba Medical) equipped with iterative reconstruction (ADIR-3D), AEC was adjusted with a standard deviation (SD)more » image quality noise index. The protocol SD parameter was incrementally increased to reduce patient population dose while image quality was evaluated by radiologist readers scoring the clinical utility of images on a Likert scale. Results: Plots of effective dose vs. body size (water cylinder diameter reported by the scanner) demonstrate monotonic increase in patient dose with increasing patient size. At the initial SD setting of 19 the average CTDIvol for a standard size patient was ∼ 2.0 mGy (1.2 mSv effective dose). This was reduced to ∼1.0 mGy (0.5 mSv) at an SD of 25 with no noticeable reduction in clinical utility of images as demonstrated by Likert scoring. Plots of effective patient diameter and BMI vs body size indicate that these metrics could also be used for manual technique charts. Conclusion: AEC offered consistent and reliable control of radiation output in this study. Dose for a standard size patient was reduced to one-third of the 3 mGy CTDIvol limit required for ACR accreditation of lung cancer CT screening. Gary Arbique: Research Grant, Toshiba America Medical Systems; Cecelia Brewington: Research Grant, Toshiba America Medical Systems; Di Zhang: Employee, Toshiba America Medical Systems.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taguchi, Atsushi; Saito, Yuika; Watanabe, Koichi
Localized surface plasmon resonances were controlled at deep-ultraviolet (DUV) wavelengths by fabricating aluminum (Al) nanostructures in a size-controllable manner. Plasmon resonances were obtained at wavelengths from near-UV down to 270 nm (4.6 eV) depending on the fabricated structure size. Such precise size control was realized by the nanosphere lithography technique combined with additional microwave heating to shrink the spaces in a close-packed monolayer of colloidal nanosphere masks. By adjusting the microwave heating time, the sizes of the Al nanostructures could be controlled from 80 nm to 50 nm without the need to use nanosphere beads of different sizes. With themore » outstanding controllability and versatility of the presented fabrication technique, the fabricated Al nanostructure is promising for use as a DUV plasmonic substrate, a light-harvesting platform for mediating strong light-matter interactions between UV photons and molecules placed near the metal nanostructure.« less
Is there still a place for the cemented titanium femoral stem?
2012-01-01
Background and purpose Despite the fact that there have been some reports on poor performance, titanium femoral stems intended for cemented fixation are still used at some centers in Europe. In this population-based registry study, we examined the results of the most frequently used cemented titanium stem in Norway. Patients and methods 11,876 cases implanted with the cemented Titan stem were identified for the period 1987–2008. Hybrid arthroplasties were excluded, leaving 10,108 cases for this study. Stem survival and the influence of age, sex, stem offset and size, and femoral head size were evaluated using Cox regression analyses. Questionnaires were sent to the hospitals to determine the surgical technique used. Results Male sex, high stem offset, and small stem size were found to be risk factors for stem revision, (adjusted RR = 2.5 (1.9–3.4), 3.3 (2.3–4.8), and 2.2 (1.4–3.5), respectively). Patients operated in the period 2001–2008 had an adjusted relative risk (RR) of 4.7 (95% CI: 3.0–7.4) for stem revision due to aseptic stem loosening compared to the period 1996–2000. Changes in broaching technique and cementing technique coincided with deterioration of the results in some hospitals. Interpretation The increased use of small stem sizes and high-offset stems could only explain the deterioration of results to a certain degree since the year 2000. The influence of discrete changes in surgical technique over time could not be fully evaluated in this registry study. We suggest that this cemented titanium stem should be abandoned. The results of similar implants should be carefully evaluated. PMID:22206445
Photothermal generation of microbubbles on plasmonic nanostructures inside microfluidic channels
NASA Astrophysics Data System (ADS)
Li, Jingting; Li, Ming; Santos, Greggy M.; Zhao, Fusheng; Shih, Wei-Chuan
2016-03-01
Microbubbles have been utilized as micro-pumps, micro-mixers, micro-valves, micro-robots and surface cleaners. Various generation techniques can be found in the literature, including resistive heating, hydrodynamic methods, illuminating patterned metal films and noble metal nanoparticles of Au or Ag. We present photothermal microbubble generation by irradiating nanoporous gold disk covered microfluidic channels. The size of the microbubble can be controlled by adjusting the laser power. The dynamics of both bubble growth and shrinkage are studied. The advantages of this technique are flexible bubble generation locations, long bubble lifetimes, no need for light-adsorbing dyes, high controllability over bubble size, low power consumption, etc. This technique has the potential to provide new flow control functions in microfluidic devices.
NASA Astrophysics Data System (ADS)
Tritscher, Torsten; Koched, Amine; Han, Hee-Siew; Filimundi, Eric; Johnson, Tim; Elzey, Sherrie; Avenido, Aaron; Kykal, Carsten; Bischof, Oliver F.
2015-05-01
Electrical mobility classification (EC) followed by Condensation Particle Counter (CPC) detection is the technique combined in Scanning Mobility Particle Sizers(SMPS) to retrieve nanoparticle size distributions in the range from 2.5 nm to 1 μm. The detectable size range of SMPS systems can be extended by the addition of an Optical Particle Sizer(OPS) that covers larger sizes from 300 nm to 10 μm. This optical sizing method reports an optical equivalent diameter, which is often different from the electrical mobility diameter measured by the standard SMPS technique. Multi-Instrument Manager (MIMTM) software developed by TSI incorporates algorithms that facilitate merging SMPS data sets with data based on optical equivalent diameter to compile single, wide-range size distributions. Here we present MIM 2.0, the next-generation of the data merging tool that offers many advanced features for data merging and post-processing. MIM 2.0 allows direct data acquisition with OPS and NanoScan SMPS instruments to retrieve real-time particle size distributions from 10 nm to 10 μm, which we show in a case study at a fireplace. The merged data can be adjusted using one of the merging options, which automatically determines an overall aerosol effective refractive index. As a result an indirect and average characterization of aerosol optical and shape properties is possible. The merging tool allows several pre-settings, data averaging and adjustments, as well as the export of data sets and fitted graphs. MIM 2.0 also features several post-processing options for SMPS data and differences can be visualized in a multi-peak sample over a narrow size range.
Gradually truncated log-normal in USA publicly traded firm size distribution
NASA Astrophysics Data System (ADS)
Gupta, Hari M.; Campanha, José R.; de Aguiar, Daniela R.; Queiroz, Gabriel A.; Raheja, Charu G.
2007-03-01
We study the statistical distribution of firm size for USA and Brazilian publicly traded firms through the Zipf plot technique. Sale size is used to measure firm size. The Brazilian firm size distribution is given by a log-normal distribution without any adjustable parameter. However, we also need to consider different parameters of log-normal distribution for the largest firms in the distribution, which are mostly foreign firms. The log-normal distribution has to be gradually truncated after a certain critical value for USA firms. Therefore, the original hypothesis of proportional effect proposed by Gibrat is valid with some modification for very large firms. We also consider the possible mechanisms behind this distribution.
Alvarez, J.L.; Watson, L.D.
1988-01-21
An apparatus and method for continuously analyzing liquids by creating a supersonic spray which is shaped and sized prior to delivery of the spray to a analysis apparatus. The gas and liquid is sheared into small particles which are of a size and uniformity to form a spray which can be controlled through adjustment of pressures and gas velocity. The spray is shaped by a concentric supplemental flow of gas. 5 figs.
Analysis of atomic force microscopy data for surface characterization using fuzzy logic
DOE Office of Scientific and Technical Information (OSTI.GOV)
Al-Mousa, Amjed, E-mail: aalmousa@vt.edu; Niemann, Darrell L.; Niemann, Devin J.
2011-07-15
In this paper we present a methodology to characterize surface nanostructures of thin films. The methodology identifies and isolates nanostructures using Atomic Force Microscopy (AFM) data and extracts quantitative information, such as their size and shape. The fuzzy logic based methodology relies on a Fuzzy Inference Engine (FIE) to classify the data points as being top, bottom, uphill, or downhill. The resulting data sets are then further processed to extract quantitative information about the nanostructures. In the present work we introduce a mechanism which can consistently distinguish crowded surfaces from those with sparsely distributed structures and present an omni-directional searchmore » technique to improve the structural recognition accuracy. In order to demonstrate the effectiveness of our approach we present a case study which uses our approach to quantitatively identify particle sizes of two specimens each with a unique gold nanoparticle size distribution. - Research Highlights: {yields} A Fuzzy logic analysis technique capable of characterizing AFM images of thin films. {yields} The technique is applicable to different surfaces regardless of their densities. {yields} Fuzzy logic technique does not require manual adjustment of the algorithm parameters. {yields} The technique can quantitatively capture differences between surfaces. {yields} This technique yields more realistic structure boundaries compared to other methods.« less
Nanoparticle coated optical fibers for single microbubble generation
NASA Astrophysics Data System (ADS)
Pimentel-Domínguez, Reinher; Hernández-Cordero, Juan
2011-09-01
The study of bubbles and bubbly flows is important in various fields such as physics, chemistry, medicine, geophysics, and even the food industry. A wide variety of mechanical and acoustic techniques have been reported for bubble generation. Although a single bubble may be generated with these techniques, controlling the size and the mean lifetime of the bubble remains a difficult task. Most of the optical methods for generation of microbubbles involve high-power pulsed laser sources focused in absorbing media such as liquids or particle solutions. With these techniques, single micron-sized bubbles can be generated with typical mean lifetimes ranging from nano to microseconds. The main problem with these bubbles is their abrupt implosion: this produces a shock wave that can potentially produce damages on the surroundings. These effects have to be carefully controlled in biological applications and in laser surgery, but thus far, not many options are available to effectively control micron-size bubble growth. In this paper, we present a new technique to generate microbubbles in non-absorbing liquids. In contrast to previous reports, the proposed technique uses low-power and a CW radiation from a laser diode. The laser light is guided through an optical fiber whose output end has been coated with nanostructures. Upon immersing the tip of the fiber in ethanol or water, micron-size bubbles can be readily generated. With this technique, bubble growth can be controlled through adjustments on the laser power. We have obtained micron-sized bubbles with mean lifetimes in the range of seconds. Furthermore, the generated bubbles do not implode, as verified with a high-speed camera and flow visualization techniques.
Double emulsion formation through hierarchical flow-focusing microchannel
NASA Astrophysics Data System (ADS)
Azarmanesh, Milad; Farhadi, Mousa; Azizian, Pooya
2016-03-01
A microfluidic device is presented for creating double emulsions, controlling their sizes and also manipulating encapsulation processes. As a result of three immiscible liquids' interaction using dripping instability, double emulsions can be produced elegantly. Effects of dimensionless numbers are investigated which are Weber number of the inner phase (Wein), Capillary number of the inner droplet (Cain), and Capillary number of the outer droplet (Caout). They affect the formation process, inner and outer droplet size, and separation frequency. Direct numerical simulation of governing equations was done using volume of fluid method and adaptive mesh refinement technique. Two kinds of double emulsion formation, the two-step and the one-step, were simulated in which the thickness of the sheath of double emulsions can be adjusted. Altering each dimensionless number will change detachment location, outer droplet size and droplet formation period. Moreover, the decussate regime of the double-emulsion/empty-droplet is observed in low Wein. This phenomenon can be obtained by adjusting the Wein in which the maximum size of the sheath is discovered. Also, the results show that Cain has significant influence on the outer droplet size in the two-step process, while Caout affects the sheath in the one-step formation considerably.
Strauss, Keith J
2014-10-01
The management of image quality and radiation dose during pediatric CT scanning is dependent on how well one manages the radiographic techniques as a function of the type of exam, type of CT scanner, and patient size. The CT scanner's display of expected CT dose index volume (CTDIvol) after the projection scan provides the operator with a powerful tool prior to the patient scan to identify and manage appropriate CT techniques, provided the department has established appropriate diagnostic reference levels (DRLs). This paper provides a step-by-step process that allows the development of DRLs as a function of type of exam, of actual patient size and of the individual radiation output of each CT scanner in a department. Abdomen, pelvis, thorax and head scans are addressed. Patient sizes from newborns to large adults are discussed. The method addresses every CT scanner regardless of vendor, model or vintage. We cover adjustments to techniques to manage the impact of iterative reconstruction and provide a method to handle all available voltages other than 120 kV. This level of management of CT techniques is necessary to properly monitor radiation dose and image quality during pediatric CT scans.
Alvarez, Joseph L.; Watson, Lloyd D.
1989-01-01
An apparatus and method for continuously analyzing liquids by creating a supersonic spray which is shaped and sized prior to delivery of the spray to a analysis apparatus. The gas and liquid are mixed in a converging-diverging nozzle where the liquid is sheared into small particles which are of a size and uniformly to form a spray which can be controlled through adjustment of pressures and gas velocity. The spray is shaped by a concentric supplemental flow of gas.
Spot size measurement of a flash-radiography source using the pinhole imaging method
NASA Astrophysics Data System (ADS)
Wang, Yi; Li, Qin; Chen, Nan; Cheng, Jin-Ming; Xie, Yu-Tong; Liu, Yun-Long; Long, Quan-Hong
2016-07-01
The spot size of the X-ray source is a key parameter of a flash-radiography facility, and is usually quoted as an evaluation of the resolving power. The pinhole imaging technique is applied to measure the spot size of the Dragon-I linear induction accelerator, by which a two-dimensional spatial distribution of the source spot is obtained. Experimental measurements are performed to measure the spot image when the transportation and focusing of the electron beam are tuned by adjusting the currents of solenoids in the downstream section. The spot size of full-width at half maximum and that defined from the spatial frequency at half peak value of the modulation transfer function are calculated and discussed.
Statistical issues in reporting quality data: small samples and casemix variation.
Zaslavsky, A M
2001-12-01
To present two key statistical issues that arise in analysis and reporting of quality data. Casemix variation is relevant to quality reporting when the units being measured have differing distributions of patient characteristics that also affect the quality outcome. When this is the case, adjustment using stratification or regression may be appropriate. Such adjustments may be controversial when the patient characteristic does not have an obvious relationship to the outcome. Stratified reporting poses problems for sample size and reporting format, but may be useful when casemix effects vary across units. Although there are no absolute standards of reliability, high reliabilities (interunit F > or = 10 or reliability > or = 0.9) are desirable for distinguishing above- and below-average units. When small or unequal sample sizes complicate reporting, precision may be improved using indirect estimation techniques that incorporate auxiliary information, and 'shrinkage' estimation can help to summarize the strength of evidence about units with small samples. With broader understanding of casemix adjustment and methods for analyzing small samples, quality data can be analysed and reported more accurately.
NASA Astrophysics Data System (ADS)
Livshts, Mikhail A.; Khomyakova, Elena; Evtushenko, Evgeniy G.; Lazarev, Vassili N.; Kulemin, Nikolay A.; Semina, Svetlana E.; Generozov, Edward V.; Govorun, Vadim M.
2015-11-01
Exosomes, small (40-100 nm) extracellular membranous vesicles, attract enormous research interest because they are carriers of disease markers and a prospective delivery system for therapeutic agents. Differential centrifugation, the prevalent method of exosome isolation, frequently produces dissimilar and improper results because of the faulty practice of using a common centrifugation protocol with different rotors. Moreover, as recommended by suppliers, adjusting the centrifugation duration according to rotor K-factors does not work for “fixed-angle” rotors. For both types of rotors - “swinging bucket” and “fixed-angle” - we express the theoretically expected proportion of pelleted vesicles of a given size and the “cut-off” size of completely sedimented vesicles as dependent on the centrifugation force and duration and the sedimentation path-lengths. The proper centrifugation conditions can be selected using relatively simple theoretical estimates of the “cut-off” sizes of vesicles. Experimental verification on exosomes isolated from HT29 cell culture supernatant confirmed the main theoretical statements. Measured by the nanoparticle tracking analysis (NTA) technique, the concentration and size distribution of the vesicles after centrifugation agree with those theoretically expected. To simplify this “cut-off”-size-based adjustment of centrifugation protocol for any rotor, we developed a web-calculator.
Vision correction via multi-layer pattern corneal surgery
NASA Astrophysics Data System (ADS)
Sun, Han-Yin; Wang, Hsiang-Chen; Yang, Shun-Fa
2013-07-01
With the rapid development of vision correction techniques, increasing numbers of people have undergone laser vision corrective surgery in recent years. The use of a laser scalpel instead of a traditional surgical knife reduces the size of the wound and quickens recovery after surgery. The primary objective of this article is to examine corneal surgery for vision correction via multi-layer swim-ring-shaped wave circles of the technique through optical simulations with the use of Monte-Carlo ray tracing method. Presbyopia stems from the loss of flexibility of crystalline lens due to aging of the eyeball. Diopter adjustment of a normal crystalline lens could reach 5 D; in the case of presbyopia, the adjustment was approximately 1 D, which made patients unable to see objects clearly in near distance. Corneal laser surgery with multi-layer swim-ring-shaped wave circles was performed, which ablated multiple circles on the cornea to improve flexibility of the crystalline lens. Simulation results showed that the ability of the crystalline lens to adjust increased tremendously from 1 D to 4 D. The method was also used to compare the images displayed on the retina before and after the treatment. The results clearly indicated a significant improvement in presbyopia symptoms with the use of this technique.
NASA Technical Reports Server (NTRS)
Gray, Perry; Guven, Ibrahim
2016-01-01
A new facility for making small particle impacts is being developed at NASA. Current sand/particle impact facilities are an erosion test and do not precisely measure and document the size and velocity of each of the impacting particles. In addition, evidence of individual impacts is often obscured by subsequent impacts. This facility will allow the number, size, and velocity of each particle to be measured and adjusted. It will also be possible to determine which particle produced damage at a given location on the target. The particle size and velocity will be measured by high speed imaging techniques. Information as to the extent of damage and debris from impacts will also be recorded. It will be possible to track these secondary particles, measuring size and velocity. It is anticipated that this additional degree of detail will provide input for erosion models and also help determine the impact physics of the erosion process. Particle impacts will be recorded at 90 degrees to the particle flight path and also from the top looking through the target window material.
Bergh, Daniel
2015-01-01
Chi-square statistics are commonly used for tests of fit of measurement models. Chi-square is also sensitive to sample size, which is why several approaches to handle large samples in test of fit analysis have been developed. One strategy to handle the sample size problem may be to adjust the sample size in the analysis of fit. An alternative is to adopt a random sample approach. The purpose of this study was to analyze and to compare these two strategies using simulated data. Given an original sample size of 21,000, for reductions of sample sizes down to the order of 5,000 the adjusted sample size function works as good as the random sample approach. In contrast, when applying adjustments to sample sizes of lower order the adjustment function is less effective at approximating the chi-square value for an actual random sample of the relevant size. Hence, the fit is exaggerated and misfit under-estimated using the adjusted sample size function. Although there are big differences in chi-square values between the two approaches at lower sample sizes, the inferences based on the p-values may be the same.
Computed Tomography to Estimate the Representative Elementary Area for Soil Porosity Measurements
Borges, Jaqueline Aparecida Ribaski; Pires, Luiz Fernando; Belmont Pereira, André
2012-01-01
Computed tomography (CT) is a technique that provides images of different solid and porous materials. CT could be an ideal tool to study representative sizes of soil samples because of the noninvasive characteristic of this technique. The scrutiny of such representative elementary sizes (RESs) has been the target of attention of many researchers related to soil physics field owing to the strong relationship between physical properties and size of the soil sample. In the current work, data from gamma-ray CT were used to assess RES in measurements of soil porosity (ϕ). For statistical analysis, a study on the full width at a half maximum (FWHM) of the adjustment of distribution of ϕ at different areas (1.2 to 1162.8 mm2) selected inside of tomographic images was proposed herein. The results obtained point out that samples with a section area corresponding to at least 882.1 mm2 were the ones that provided representative values of ϕ for the studied Brazilian tropical soil. PMID:22666133
Ende, J F; Huda, W; Ros, P R; Litwiller, A L
1999-04-01
To investigate image mottle in conventional CT images of the abdomen as a function of radiographic technique factors and patient size. Water-filled phantoms simulating the abdomens of adult (32 cm in diameter) and pediatric (16 cm in diameter) patients were used to investigate image mottle in CT as a function of x-ray tube potential and mAs. CT images from 39 consecutive patients with noncontrast liver scans and 49 patients with iodine contrast scans were analyzed retrospectively. Measurements were made of the mean liver parenchyma Hounsfield unit value and the corresponding image mottle. For a given water phantom and x-ray tube potential, image mottle was proportional to the mAs-0.5. Increasing the phantom diameter from 16 cm (pediatric) to 32 cm increased the mottle by a factor of 2.4, and increasing the x-ray tube potential from 80 kVp to 140 kVp reduced the mottle by a factor of 2.5. All patients were scanned at 120 kVp, with no correlation between patient size and the x-ray tube mAs. The mean mottle level was 7.8 +/- 2.2 and 10.0 +/- 2.5 for the noncontrast and contrast studies, respectively. An increase in patient diameter of 3 cm would require approximately 65% more mAs to maintain the same level of image mottle. The mottle in abdominal CT images may be controlled by adjusting radiographic technique factors, which should be adjusted to take into account the size of the patient undergoing the examination.
39 CFR 3010.28 - Maximum size of unused rate adjustment authority rate adjustments.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 39 Postal Service 1 2010-07-01 2010-07-01 false Maximum size of unused rate adjustment authority rate adjustments. 3010.28 Section 3010.28 Postal Service POSTAL REGULATORY COMMISSION PERSONNEL REGULATION OF RATES FOR MARKET DOMINANT PRODUCTS Rules for Applying the Price Cap § 3010.28 Maximum size of...
Experimental Determination of Infrared Extinction Coefficients of Interplanetary Dust Particles
NASA Technical Reports Server (NTRS)
Spann, J. F., Jr.; Abbas, M. M.
1998-01-01
This technique is based on irradiating a single isolated charged dust particle suspended in balance by an electric field, and measuring the scattered radiation as a function of angle. The observed scattered intensity profile at a specific wavelength obtained for a dust particle of known composition is compared with Mie theory calculations, and the variable parameters relating to the particle size and complex refractive index are adjusted for a best fit between the two profiles. This leads to a simultaneous determination of the particle radius, the complex refractive index, and the scattering and extinction coefficients. The results of these experiments can be utilized to examine the IRAS and DIRBE (Diffuse Infrared Background Experiment) infrared data sets in order to determine the dust particle physical characteristics and distributions by using infrared models and inversion techniques. This technique may also be employed for investigation of the rotational bursting phenomena whereby large size cosmic and interplanetary particles are believed to fragment into smaller dust particles.
Ripcord adjustable suture technique for use in strabismus surgery.
Coats, D K
2001-09-01
Adjustable sutures in strabismus surgery may be difficult or impossible in poorly cooperative patients. An adjunct suture technique that allows a 1-step, all-or-nothing, preprogrammed adjustment in patients not considered good candidates for standard postoperative adjustable sutures is described. Twelve patients underwent adjustable strabismus surgery using the ripcord technique. Six patients had unacceptable alignment after surgery. In 5 of these, alignment was successfully adjusted. The ripcord adjustable suture technique is effective and is well tolerated by patients.
DARHT Axis-I Diode Simulations II: Geometrical Scaling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ekdahl, Carl A. Jr.
2012-06-14
Flash radiography of large hydrodynamic experiments driven by high explosives is a venerable diagnostic technique in use at many laboratories. Many of the largest hydrodynamic experiments study mockups of nuclear weapons, and are often called hydrotests for short. The dual-axis radiography for hydrodynamic testing (DARHT) facility uses two electron linear-induction accelerators (LIA) to produce the radiographic source spots for perpendicular views of a hydrotest. The first of these LIAs produces a single pulse, with a fixed {approx}60-ns pulsewidth. The second axis LIA produces as many as four pulses within 1.6-{micro}s, with variable pulsewidths and separation. There are a wide varietymore » of hydrotest geometries, each with a unique radiographic requirement, so there is a need to adjust the radiographic dose for the best images. This can be accomplished on the second axis by simply adjusting the pulsewidths, but is more problematic on the first axis. Changing the beam energy or introducing radiation attenuation also changes the spectrum, which is undesirable. Moreover, using radiation attenuation introduces significant blur, increasing the effective spot size. The dose can also be adjusted by changing the beam kinetic energy. This is a very sensitive method, because the dose scales as the {approx}2.8 power of the energy, but it would require retuning the accelerator. This leaves manipulating the beam current as the best means for adjusting the dose, and one way to do this is to change the size of the cathode. This method has been proposed, and is being tested. This article describes simulations undertaken to develop scaling laws for use as design tools in changing the Axis-1 beam current by changing the cathode size.« less
NASA Astrophysics Data System (ADS)
O'Rourke, Matthew B.; Raymond, Benjamin B. A.; Djordjevic, Steven P.; Padula, Matthew P.
2018-03-01
Tissue imaging using matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a well-established technique that, in recent years, has seen wider adoption and novel application. Applications such imaging mass spectrometry (IMS) and biotyping are beginning to gain greater exposure and use; however, with limitations in optimization methods, producing the best result often relies on the ability to customize the physical characteristics of the instrumentation, a task that is challenging for most mass spectrometry laboratories. With this in mind, we have described the effect of making simple adjustments to the laser optics at the final collimating lens area, to adjust the laser beam size and shape in order to allow greater customization of the instrument for improving techniques such as IMS. We have therefore been able to demonstrate that improvements can be made without requiring the help of an electrical engineer or external funding in a way that only costs a small amount of time. [Figure not available: see fulltext.
O'Rourke, Matthew B; Raymond, Benjamin B A; Djordjevic, Steven P; Padula, Matthew P
2018-03-01
Tissue imaging using matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) is a well-established technique that, in recent years, has seen wider adoption and novel application. Applications such imaging mass spectrometry (IMS) and biotyping are beginning to gain greater exposure and use; however, with limitations in optimization methods, producing the best result often relies on the ability to customize the physical characteristics of the instrumentation, a task that is challenging for most mass spectrometry laboratories. With this in mind, we have described the effect of making simple adjustments to the laser optics at the final collimating lens area, to adjust the laser beam size and shape in order to allow greater customization of the instrument for improving techniques such as IMS. We have therefore been able to demonstrate that improvements can be made without requiring the help of an electrical engineer or external funding in a way that only costs a small amount of time. Graphical Abstract ᅟ.
The Ontogeny of Gap Crossing Behaviour in Bornean Orangutans (Pongo pygmaeus wurmbii)
Chappell, Jackie; Phillips, Abigail C.; van Noordwijk, Maria A.; Mitra Setia, Tatang; Thorpe, Susannah K. S.
2015-01-01
For orangutans, the largest predominantly arboreal primates, discontinuous canopy presents a particular challenge. The shortest gaps between trees lie between thin peripheral branches, which offer the least stability to large animals. The affordances of the forest canopy experienced by orangutans of different ages however, must vary substantially as adult males are an order of magnitude larger in size than infants during the early stages of locomotor independence. Orangutans have developed a diverse range of locomotor behaviour to cross gaps between trees, which vary in their physical and cognitive demands. The aims of this study were to examine the ontogeny of orangutan gap crossing behaviours and to determine which factors influence the distance orangutans crossed. A non-invasive photographic technique was used to quantify forearm length as a measure of body size. We also recorded locomotor behaviour, support use and the distance crossed between trees. Our results suggest that gap crossing varies with both physical and cognitive development. More complex locomotor behaviours, which utilized compliant trunks and lianas, were used to cross the largest gaps, but these peaked in frequency much earlier than expected, between the ages of 4 and 5 years old, which probably reflects play behaviour to perfect locomotor techniques. Smaller individuals also crossed disproportionately large gaps relative to their size, by using support deformation. Our results suggest that orangutans acquire the full repertoire of gap crossing techniques, including the more cognitively demanding ones, before weaning, but adjust the frequency of the use of these techniques to their increasing body size. PMID:26154061
The Ontogeny of Gap Crossing Behaviour in Bornean Orangutans (Pongo pygmaeus wurmbii).
Chappell, Jackie; Phillips, Abigail C; van Noordwijk, Maria A; Mitra Setia, Tatang; Thorpe, Susannah K S
2015-01-01
For orangutans, the largest predominantly arboreal primates, discontinuous canopy presents a particular challenge. The shortest gaps between trees lie between thin peripheral branches, which offer the least stability to large animals. The affordances of the forest canopy experienced by orangutans of different ages however, must vary substantially as adult males are an order of magnitude larger in size than infants during the early stages of locomotor independence. Orangutans have developed a diverse range of locomotor behaviour to cross gaps between trees, which vary in their physical and cognitive demands. The aims of this study were to examine the ontogeny of orangutan gap crossing behaviours and to determine which factors influence the distance orangutans crossed. A non-invasive photographic technique was used to quantify forearm length as a measure of body size. We also recorded locomotor behaviour, support use and the distance crossed between trees. Our results suggest that gap crossing varies with both physical and cognitive development. More complex locomotor behaviours, which utilized compliant trunks and lianas, were used to cross the largest gaps, but these peaked in frequency much earlier than expected, between the ages of 4 and 5 years old, which probably reflects play behaviour to perfect locomotor techniques. Smaller individuals also crossed disproportionately large gaps relative to their size, by using support deformation. Our results suggest that orangutans acquire the full repertoire of gap crossing techniques, including the more cognitively demanding ones, before weaning, but adjust the frequency of the use of these techniques to their increasing body size.
Modular Bundle Adjustment for Photogrammetric Computations
NASA Astrophysics Data System (ADS)
Börlin, N.; Murtiyoso, A.; Grussenmeyer, P.; Menna, F.; Nocerino, E.
2018-05-01
In this paper we investigate how the residuals in bundle adjustment can be split into a composition of simple functions. According to the chain rule, the Jacobian (linearisation) of the residual can be formed as a product of the Jacobians of the individual steps. When implemented, this enables a modularisation of the computation of the bundle adjustment residuals and Jacobians where each component has limited responsibility. This enables simple replacement of components to e.g. implement different projection or rotation models by exchanging a module. The technique has previously been used to implement bundle adjustment in the open-source package DBAT (Börlin and Grussenmeyer, 2013) based on the Photogrammetric and Computer Vision interpretations of Brown (1971) lens distortion model. In this paper, we applied the technique to investigate how affine distortions can be used to model the projection of a tilt-shift lens. Two extended distortion models were implemented to test the hypothesis that the ordering of the affine and lens distortion steps can be changed to reduce the size of the residuals of a tilt-shift lens calibration. Results on synthetic data confirm that the ordering of the affine and lens distortion steps matter and is detectable by DBAT. However, when applied to a real camera calibration data set of a tilt-shift lens, no difference between the extended models was seen. This suggests that the tested hypothesis is false and that other effects need to be modelled to better explain the projection. The relatively low implementation effort that was needed to generate the models suggest that the technique can be used to investigate other novel projection models in photogrammetry, including modelling changes in the 3D geometry to better understand the tilt-shift lens.
Bicycle helmet size, adjustment, and stability.
Thai, Kim T; McIntosh, Andrew S; Pang, Toh Yen
2015-01-01
One of the main requirements of a protective bicycle helmet is to provide and maintain adequate coverage to the head. A poorly fitting or fastened helmet may be displaced during normal use or even ejected during a crash. The aims of the current study were to identify factors that influence the size of helmet worn, identify factors that influence helmet position and adjustment, and examine the effects of helmet size worn and adjustment on helmet stability. Recreational and commuter cyclists in Sydney were surveyed to determine how helmet size and/or adjustment affected helmet stability in the real world. Anthropometric characteristics of the head were measured and, to assess helmet stability, a test analogous to the requirements of the Australian bicycle helmet standard was undertaken. Two hundred sixty-seven cyclists were recruited across all age groups and 91% wore an AS/NZS 2063-compliant helmet. The main ethnic group was Europeans (71%) followed by Asians (18%). The circumferences of the cyclists' heads matched well the circumference of the relevant ISO headform for the chosen helmet size, but the head shapes differed with respect to ISO headforms. Age and gender were associated with wearing an incorrectly sized helmet and helmet adjustment. Older males (>55 years) were most likely to wear an incorrectly sized helmet. Adult males in the 35-54 year age group were most likely to wear a correctly adjusted helmet. Using quasistatic helmet stability tests, it was found that the correctness of adjustment, rather than size, head dimensions, or shape, significantly affected helmet stability in all test directions. Bicycle helmets worn by recreational and commuter cyclists are often the wrong size and are often worn and adjusted incorrectly, especially in children and young people. Cyclists need to be encouraged to adjust their helmets correctly. Current headforms used in standards testing may not be representative of cyclists' head shapes. This may create challenges to helmet suppliers if on one hand they optimize the helmet to meet tests on ISO-related headforms while on the other seeking to offer greater range of sizes.
Variable pixel size ionospheric tomography
NASA Astrophysics Data System (ADS)
Zheng, Dunyong; Zheng, Hongwei; Wang, Yanjun; Nie, Wenfeng; Li, Chaokui; Ao, Minsi; Hu, Wusheng; Zhou, Wei
2017-06-01
A novel ionospheric tomography technique based on variable pixel size was developed for the tomographic reconstruction of the ionospheric electron density (IED) distribution. In variable pixel size computerized ionospheric tomography (VPSCIT) model, the IED distribution is parameterized by a decomposition of the lower and upper ionosphere with different pixel sizes. Thus, the lower and upper IED distribution may be very differently determined by the available data. The variable pixel size ionospheric tomography and constant pixel size tomography are similar in most other aspects. There are some differences between two kinds of models with constant and variable pixel size respectively, one is that the segments of GPS signal pay should be assigned to the different kinds of pixel in inversion; the other is smoothness constraint factor need to make the appropriate modified where the pixel change in size. For a real dataset, the variable pixel size method distinguishes different electron density distribution zones better than the constant pixel size method. Furthermore, it can be non-chided that when the effort is spent to identify the regions in a model with best data coverage. The variable pixel size method can not only greatly improve the efficiency of inversion, but also produce IED images with high fidelity which are the same as a used uniform pixel size method. In addition, variable pixel size tomography can reduce the underdetermined problem in an ill-posed inverse problem when the data coverage is irregular or less by adjusting quantitative proportion of pixels with different sizes. In comparison with constant pixel size tomography models, the variable pixel size ionospheric tomography technique achieved relatively good results in a numerical simulation. A careful validation of the reliability and superiority of variable pixel size ionospheric tomography was performed. Finally, according to the results of the statistical analysis and quantitative comparison, the proposed method offers an improvement of 8% compared with conventional constant pixel size tomography models in the forward modeling.
Molecular quenching and relaxation in a plasmonic tunable system
NASA Astrophysics Data System (ADS)
Baffou, Guillaume; Girard, Christian; Dujardin, Erik; Colas Des Francs, Gérard; Martin, Olivier J. F.
2008-03-01
Molecular fluorescence decay is significantly modified when the emitting molecule is located near a plasmonic structure. When the lateral sizes of such structures are reduced to nanometer-scale cross sections, they can be used to accurately control and amplify the emission rate. In this Rapid Communication, we extend Green’s dyadic method to quantitatively investigate both radiative and nonradiative decay channels experienced by a single fluorescent molecule confined in an adjustable dielectric-metal nanogap. The technique produces data in excellent agreement with current experimental work.
Silicon Technologies Adjust to RF Applications
NASA Technical Reports Server (NTRS)
Reinecke Taub, Susan; Alterovitz, Samuel A.
1994-01-01
Silicon (Si), although not traditionally the material of choice for RF and microwave applications, has become a serious challenger to other semiconductor technologies for high-frequency applications. Fine-line electron- beam and photolithographic techniques are now capable of fabricating silicon gate sizes as small as 0.1 micron while commonly-available high-resistivity silicon wafers support low-loss microwave transmission lines. These advances, coupled with the recent development of silicon-germanium (SiGe), arm silicon integrated circuits (ICs) with the speed required for increasingly higher-frequency applications.
Flood Detection/Monitoring Using Adjustable Histogram Equalization Technique
Riaz, Muhammad Mohsin; Ghafoor, Abdul
2014-01-01
Flood monitoring technique using adjustable histogram equalization is proposed. The technique overcomes the limitations (overenhancement, artifacts, and unnatural look) of existing technique by adjusting the contrast of images. The proposed technique takes pre- and postimages and applies different processing steps for generating flood map without user interaction. The resultant flood maps can be used for flood monitoring and detection. Simulation results show that the proposed technique provides better output quality compared to the state of the art existing technique. PMID:24558332
Bond, Jason C; Greenfield, Thomas K; Patterson, Deidre; Kerr, William C
2014-12-01
Prior studies adjusting self-reported measures of alcohol intake for drink size and ethanol (EtOH) content have relied on single-point assessments. A prospective 28-day diary study investigated magnitudes of drink-EtOH adjustments and factors associated with these adjustments. Transdermal alcohol sensor (TAS) readings and prediction of alcohol-related problems by number of drinks versus EtOH-adjusted intake were used to validate drink-EtOH adjustments. Self-completed event diaries listed up to 4 beverage types and 4 drinking events/d. Eligible volunteers had ≥ weekly drinking and ≥3+ drinks per occasion with ≥26 reported days and pre- and postsummary measures (n = 220). Event reports included drink types, sizes, brands or spirits contents, venues, drinks consumed, and drinking duration. Wine drinks averaged 1.19, beer 1.09, and spirits 1.54 U.S. standard drinks (14 g EtOH). Mean-adjusted alcohol intake was 22% larger using drink size and strength (brand/EtOH concentration) data. Adjusted drink levels were larger than "raw" drinks in all quantity ranges. Individual-level drink-EtOH adjustment ratios (EtOH adjusted/unadjusted amounts) averaged across all days drinking ranged from 0.73 to 3.33 (mean 1.22). Adjustment ratio was only marginally (and not significantly) positively related to usual quantity, frequency, and heavy drinking (all ps < 0.10), independent of gender, age, employment, and education, but those with lower incomes (both p < 0.01) drank stronger/bigger drinks. Controlling for raw number of drinks and other covariates, degree of adjustment independently predicted alcohol dependence symptoms (p < 0.01) and number of consequences (p < 0.05). In 30 respondents with sufficiently high-quality TAS readings, higher correlations (p = 0.04) were found between the adjusted versus the raw drinks/event and TAS areas under the curve. Absent drink size and strength data, intake assessments are downward biased by at least 20%. Between-subject variation in typical drink content and pour sizes should be addressed in treatment and epidemiological research. Copyright © 2015 by the Research Society on Alcoholism.
Bond, J. C.; Greenfield, T. K.; Patterson, D.; Kerr, W.C.
2014-01-01
Background Prior studies adjusting self-reported measures of alcohol intake for drink size and ethanol content have relied on single-point assessments. Methods A prospective 28-day diary study investigated magnitudes of drink ethanol adjustments and factors associated with these adjustments. Transdermal alcohol sensor (TAS) readings and prediction of alcohol-related problems by number of drinks versus ethanol-adjusted intake were used to validate drink ethanol adjustments. Self-completed event diaries listed up to 4 beverage types and 4 drinking events/day. Eligible volunteers had ≥ weekly drinking and ≥ 3+ drinks per occasion with ≥ 26 reported days and pre- and post-summary measures (n = 220). Event reports included drink types, sizes, brands or spirits contents, venues, drinks consumed and drinking duration. Results Wine drinks averaged 1.19, beer, 1.09 and spirits 1.54 US standard drinks (14g ethanol). Mean adjusted alcohol intake was 22% larger using drink size and strength (brand/ethanol concentration) data. Adjusted drink levels were larger than “raw” drinks in all quantity ranges. Individual-level drink ethanol adjustment ratios (ethanol adjusted/unadjusted amounts) averaged across all days drinking ranged from 0.73-3.33 (mean 1.22). Adjustment ratio was only marginally (and not significantly) positively related to usual quantity, frequency and heavy drinking (all ps<.1), independent of gender, age, employment, and education, but those with lower incomes (both p<.01) drank stronger/bigger drinks. Controlling for raw number of drinks and other covariates, degree of adjustment independently predicted alcohol dependence symptoms (p<.01) and number of consequences (p<.05). In 30 respondents with sufficiently high quality TAS readings, higher correlations (p=.04) were found between the adjusted vs. the raw drinks/event and TAS areas under the curve. Conclusions Absent drink size and strength data, intake assessments are downward biased by at least 20%. Between-subject variation in typical drink content and pour sizes should be addressed in treatment and epidemiological research. PMID:25581661
NASA Technical Reports Server (NTRS)
Bloemhof, E. E.; Danen, R. M.; Gwinn, C. R.
1996-01-01
We describe how high spatial resolution imaging of circumstellar dust at a wavelength of about 10 micron, combined with knowledge of the source spectral energy distribution, can yield useful information about the sizes of the individual dust grains responsible for the infrared emission. Much can be learned even when only upper limits to source size are available. In parallel with high-resolution single-telescope imaging that may resolve the more extended mid-infrared sources, we plan to apply these less direct techniques to interpretation of future observations from two-element optical interferometers, where quite general arguments may be made despite only crude imaging capability. Results to date indicate a tendency for circumstellar grain sizes to be rather large compared to the Mathis-Rumpl-Nordsieck size distribution traditionally thought to characterize dust in the general interstellar medium. This may mean that processing of grains after their initial formation and ejection from circumstellar atmospheres adjusts their size distribution to the ISM curve; further mid-infrared observations of grains in various environments would help to confirm this conjecture.
Hagell, Peter; Westergren, Albert
Sample size is a major factor in statistical null hypothesis testing, which is the basis for many approaches to testing Rasch model fit. Few sample size recommendations for testing fit to the Rasch model concern the Rasch Unidimensional Measurement Models (RUMM) software, which features chi-square and ANOVA/F-ratio based fit statistics, including Bonferroni and algebraic sample size adjustments. This paper explores the occurrence of Type I errors with RUMM fit statistics, and the effects of algebraic sample size adjustments. Data with simulated Rasch model fitting 25-item dichotomous scales and sample sizes ranging from N = 50 to N = 2500 were analysed with and without algebraically adjusted sample sizes. Results suggest the occurrence of Type I errors with N less then or equal to 500, and that Bonferroni correction as well as downward algebraic sample size adjustment are useful to avoid such errors, whereas upward adjustment of smaller samples falsely signal misfit. Our observations suggest that sample sizes around N = 250 to N = 500 may provide a good balance for the statistical interpretation of the RUMM fit statistics studied here with respect to Type I errors and under the assumption of Rasch model fit within the examined frame of reference (i.e., about 25 item parameters well targeted to the sample).
Kobayashi, Akira; Yokogawa, Hideaki; Sugiyama, Kazuhisa
2012-01-01
Purpose One difficulty with Descemet's stripping automated endothelial keratoplasty (DSAEK) is air management during surgery and donor endothelial lamella centering. We evaluated the no-touch technique for donor centering and the use of a newly developed DSAEK donor adjuster. Methods We evaluated the records of 12 consecutive patients (mean age 75.3 years) with bullous keratopathy who had undergone DSAEK. In all cases, the no-touch technique was attempted first. When the no-touch technique failed, a DSAEK donor adjuster with a 30-gauge cannula resembling a curved reverse Sinskey hook was used for donor centering. The adjuster allows air injection during donor centering. Results The no-touch technique using simple corneal surface massage to center the graft was successful in 4 cases (33.3%), while 4 cases required ocular tilting (33.3%) in addition to corneal surface massage. The no-touch technique was ineffective in 4 cases (33.3%), but the donor adjuster was used successfully and easily for these patients. Comparing the endothelial cell loss rate between the no-touch technique group and the donor adjuster group, there was no significant difference at 6 months. Conclusions The no-touch technique was useful for better control of DSAEK donor centering in most cases. When the no-touch technique was ineffective, the DSAEK donor adjuster was uniformly successful. PMID:22807910
OPC for curved designs in application to photonics on silicon
NASA Astrophysics Data System (ADS)
Orlando, Bastien; Farys, Vincent; Schneider, Loïc.; Cremer, Sébastien; Postnikov, Sergei V.; Millequant, Matthieu; Dirrenberger, Mathieu; Tiphine, Charles; Bayle, Sébastian; Tranquillin, Céline; Schiavone, Patrick
2016-03-01
Today's design for photonics devices on silicon relies on non-Manhattan features such as curves and a wide variety of angles with minimum feature size below 100nm. Industrial manufacturing of such devices requires optimized process window with 193nm lithography. Therefore, Resolution Enhancement Techniques (RET) that are commonly used for CMOS manufacturing are required. However, most RET algorithms are based on Manhattan fragmentation (0°, 45° and 90°) which can generate large CD dispersion on masks for photonic designs. Industrial implementation of RET solutions to photonic designs is challenging as most currently available OPC tools are CMOS-oriented. Discrepancy from design to final results induced by RET techniques can lead to lower photonic device performance. We propose a novel sizing algorithm allowing adjustment of design edge fragments while preserving the topology of the original structures. The results of the algorithm implementation in the rule based sizing, SRAF placement and model based correction will be discussed in this paper. Corrections based on this novel algorithm were applied and characterized on real photonics devices. The obtained results demonstrate the validity of the proposed correction method integrated in Inscale software of Aselta Nanographics.
2015-01-01
Recent advances in RNA nanotechnology allow the rational design of various nanoarchitectures. Previous methods utilized conserved angles from natural RNA motifs to form geometries with specific sizes. However, the feasibility of producing RNA architecture with variable sizes using native motifs featuring fixed sizes and angles is limited. It would be advantageous to display RNA nanoparticles of diverse shape and size derived from a given primary sequence. Here, we report an approach to construct RNA nanoparticles with tunable size and stability. Multifunctional RNA squares with a 90° angle were constructed by tuning the 60° angle of the three-way junction (3WJ) motif from the packaging RNA (pRNA) of the bacteriophage phi29 DNA packaging motor. The physicochemical properties and size of the RNA square were also easily tuned by modulating the “core” strand and adjusting the length of the sides of the square via predictable design. Squares of 5, 10, and 20 nm were constructed, each showing diverse thermodynamic and chemical stabilities. Four “arms” extending from the corners of the square were used to incorporate siRNA, ribozyme, and fluorogenic RNA motifs. Unique intramolecular contact using the pre-existing intricacy of the 3WJ avoids relatively weaker intermolecular interactions via kissing loops or sticky ends. Utilizing the 3WJ motif, we have employed a modular design technique to construct variable-size RNA squares with controllable properties and functionalities for diverse and versatile applications with engineering, pharmaceutical, and medical potential. This technique for simple design to finely tune physicochemical properties adds a new angle to RNA nanotechnology. PMID:24971772
Relative efficiency and sample size for cluster randomized trials with variable cluster sizes.
You, Zhiying; Williams, O Dale; Aban, Inmaculada; Kabagambe, Edmond Kato; Tiwari, Hemant K; Cutter, Gary
2011-02-01
The statistical power of cluster randomized trials depends on two sample size components, the number of clusters per group and the numbers of individuals within clusters (cluster size). Variable cluster sizes are common and this variation alone may have significant impact on study power. Previous approaches have taken this into account by either adjusting total sample size using a designated design effect or adjusting the number of clusters according to an assessment of the relative efficiency of unequal versus equal cluster sizes. This article defines a relative efficiency of unequal versus equal cluster sizes using noncentrality parameters, investigates properties of this measure, and proposes an approach for adjusting the required sample size accordingly. We focus on comparing two groups with normally distributed outcomes using t-test, and use the noncentrality parameter to define the relative efficiency of unequal versus equal cluster sizes and show that statistical power depends only on this parameter for a given number of clusters. We calculate the sample size required for an unequal cluster sizes trial to have the same power as one with equal cluster sizes. Relative efficiency based on the noncentrality parameter is straightforward to calculate and easy to interpret. It connects the required mean cluster size directly to the required sample size with equal cluster sizes. Consequently, our approach first determines the sample size requirements with equal cluster sizes for a pre-specified study power and then calculates the required mean cluster size while keeping the number of clusters unchanged. Our approach allows adjustment in mean cluster size alone or simultaneous adjustment in mean cluster size and number of clusters, and is a flexible alternative to and a useful complement to existing methods. Comparison indicated that we have defined a relative efficiency that is greater than the relative efficiency in the literature under some conditions. Our measure of relative efficiency might be less than the measure in the literature under some conditions, underestimating the relative efficiency. The relative efficiency of unequal versus equal cluster sizes defined using the noncentrality parameter suggests a sample size approach that is a flexible alternative and a useful complement to existing methods.
Fast, Nonspattering Inert-Gas Welding
NASA Technical Reports Server (NTRS)
Gilbert, Jeffrey L.
1991-01-01
Proposed welding technique combines best features of metal (other than tungsten)/inert-gas welding, plasma arc welding, and tungsten/inert-gas welding. Advantages include: wire fed to weld joint preheated, therefore fed at high speed without spattering; high-frequency energy does not have to be supplied to workpiece to initiate welding; size of arc gap not critical, power-supply control circuit adjusts voltage across gap to compensate for changes; only low gas-flow rate needed; welding electrode replaced easily as prefabricated assembly; external wire-feeding manipulator not needed; and welding process relatively forgiving of operator error.
NASA Astrophysics Data System (ADS)
Lindsay, R. A.; Cox, B. V.
Universal and adaptive data compression techniques have the capability to globally compress all types of data without loss of information but have the disadvantage of complexity and computation speed. Advances in hardware speed and the reduction of computational costs have made universal data compression feasible. Implementations of the Adaptive Huffman and Lempel-Ziv compression algorithms are evaluated for performance. Compression ratios versus run times for different size data files are graphically presented and discussed in the paper. Required adjustments needed for optimum performance of the algorithms relative to theoretical achievable limits will be outlined.
Enzyme Histochemistry for Functional Histology in Invertebrates.
Cima, Francesca
2017-01-01
In invertebrates, enzyme histochemistry has recently found a renaissance regarding its applications in morphology and ecology. Many enzyme activities are useful for the morphofunctional characterization of cells, as biomarkers of biological and pathologic processes, and as markers of the response to environmental stressors. Here, the adjustments to classic techniques, including the most common enzymes used for digestion, absorption, transport, and oxidation, as well as techniques for azo-coupling, metal salt substitution and oxidative coupling polymerization, are presented in detail for various terrestrial and aquatic invertebrates. This chapter also provides strategies to solve the problems regarding anesthesia, small body size, the presence of an exo- or endoskeleton and the search for the best fixative in relation to the internal fluid osmolarity. These techniques have the aim of obtaining good results for both the pre- and post-embedding labeling of specimens, tissue blocks, sections, and hemolymph smears using both light and transmission electron microscopy.
NASA Technical Reports Server (NTRS)
Smith, Suzanne Weaver; Beattie, Christopher A.
1991-01-01
On-orbit testing of a large space structure will be required to complete the certification of any mathematical model for the structure dynamic response. The process of establishing a mathematical model that matches measured structure response is referred to as model correlation. Most model correlation approaches have an identification technique to determine structural characteristics from the measurements of the structure response. This problem is approached with one particular class of identification techniques - matrix adjustment methods - which use measured data to produce an optimal update of the structure property matrix, often the stiffness matrix. New methods were developed for identification to handle problems of the size and complexity expected for large space structures. Further development and refinement of these secant-method identification algorithms were undertaken. Also, evaluation of these techniques is an approach for model correlation and damage location was initiated.
Song, Zhuonan; Huang, Yi; Xu, Weiwei L.; Wang, Lei; Bao, Yu; Li, Shiguang; Yu, Miao
2015-01-01
Zeolites/molecular sieves with uniform, molecular-sized pores are important for many adsorption-based separation processes. Pore size gaps, however, exist in the current zeolite family. This leads to a great challenge of separating molecules with size differences at ~0.01 nm level. Here, we report a novel concept, pore misalignment, to form a continuously adjustable, molecular-sieving “gate” at the 5A zeolite pore entrance without sacrificing the internal capacity. Misalignment of the micropores of the alumina coating with the 5A zeolite pores was related with and facilely adjusted by the coating thickness. For the first time, organic molecules with sub-0.01 nm size differences were effectively distinguished via appropriate misalignment. This novel concept may have great potential to fill the pore size gaps of the zeolite family and realize size-selective adsorption separation. PMID:26358480
Song, Zhuonan; Huang, Yi; Xu, Weiwei L.; ...
2015-09-11
Zeolites/molecular sieves with uniform, molecular-sized pores are important for many adsorption-based separation processes. Pore size gaps, however, exist in the current zeolite family. This leads to a great challenge of separating molecules with size differences at ~0.01 nm level. Here, we report a novel concept, pore misalignment, to form a continuously adjustable, molecular-sieving “gate” at the 5A zeolite pore entrance without sacrificing the internal capacity. Misalignment of the micropores of the alumina coating with the 5A zeolite pores was related with and facilely adjusted by the coating thickness. For the first time, organic molecules with sub-0.01 nm size differences weremore » effectively distinguished via appropriate misalignment. Lastly, this novel concept may have great potential to fill the pore size gaps of the zeolite family and realize size-selective adsorption separation.« less
Akbarzadeh, Rosa; Yousefi, Azizeh-Mitra
2014-08-01
Tissue engineering makes use of 3D scaffolds to sustain three-dimensional growth of cells and guide new tissue formation. To meet the multiple requirements for regeneration of biological tissues and organs, a wide range of scaffold fabrication techniques have been developed, aiming to produce porous constructs with the desired pore size range and pore morphology. Among different scaffold fabrication techniques, thermally induced phase separation (TIPS) method has been widely used in recent years because of its potential to produce highly porous scaffolds with interconnected pore morphology. The scaffold architecture can be closely controlled by adjusting the process parameters, including polymer type and concentration, solvent composition, quenching temperature and time, coarsening process, and incorporation of inorganic particles. The objective of this review is to provide information pertaining to the effect of these parameters on the architecture and properties of the scaffolds fabricated by the TIPS technique. © 2014 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Zubarev, A. E.; Nadezhdina, I. E.; Brusnikin, E. S.; Karachevtseva, I. P.; Oberst, J.
2016-09-01
The new technique for generation of coordinate control point networks based on photogrammetric processing of heterogeneous planetary images (obtained at different time, scale, with different illumination or oblique view) is developed. The technique is verified with the example for processing the heterogeneous information obtained by remote sensing of Ganymede by the spacecraft Voyager-1, -2 and Galileo. Using this technique the first 3D control point network for Ganymede is formed: the error of the altitude coordinates obtained as a result of adjustment is less than 5 km. The new control point network makes it possible to obtain basic geodesic parameters of the body (axes size) and to estimate forced librations. On the basis of the control point network, digital terrain models (DTMs) with different resolutions are generated and used for mapping the surface of Ganymede with different levels of detail (Zubarev et al., 2015b).
Multiresonant layered plasmonic films
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeVetter, Brent M.; Bernacki, Bruce E.; Bennett, Wendy D.
Multi-resonant nanoplasmonic films have numerous applications in areas such as nonlinear optics, sensing, and tamper indication. While techniques such as focused ion beam milling and electron beam lithography can produce high-quality multi-resonant films, these techniques are expensive, serial processes that are difficult to scale at the manufacturing level. Here, we present the fabrication of multi-resonant nanoplasmonic films using a layered stacking technique. Periodically-spaced gold nanocup substrates were fabricated using self-assembled polystyrene nanospheres followed by oxygen plasma etching and metal deposition via magnetron sputter coating. By adjusting etch parameters and initial nanosphere size, it was possible to achieve an optical responsemore » ranging from the visible to the near-infrared. Singly resonant, flexible films were first made by performing peel-off using an adhesive-coated polyolefin film. Through stacking layers of the nanofilm, we demonstrate fabrication of multi-resonant films at a fraction of the cost and effort as compared to top-down lithographic techniques.« less
Hunik, J H; Tramper, J
1993-01-01
Immobilization of biocatalysts in kappa-carrageenan gel beads is a widely used technique nowadays. Several methods are used to produce the gel beads. The gel-bead production rate is usually sufficient to make the relatively small quantities needed for bench-scale experiments. The droplet diameter can, within limits, be adjusted to the desired size, but it is difficult to predict because of the non-Newtonian fluid behavior of the kappa-carrageenan solution. Here we present the further scale-up of the extrusion technique with the theory to predict the droplet diameters for non-Newtonian fluids. The emphasis is on the droplet formation, which is the rate-limiting step in this extrusion technique. Uniform droplets were formed by breaking up a capillary jet with a sinusoidal signal of a vibration exciter. At the maximum production rate of 27.6 dm3/h, uniform droplets with a diameter of (2.1 +/- 0.12) x 10(-3) m were obtained. This maximum flow rate was limited by the power transfer of the vibration exciter to the liquid flow. It was possible to get a good prediction of the droplet diameter by estimating the local viscosity from shear-rate calculations and an experimental relation between the shear rate and viscosity. In this way the theory of Newtonian fluids could be used for the non-Newtonian kappa-carrageenan solution. The calculated optimal break-up frequencies and droplet sizes were in good agreement with those found in the experiments.
NASA Technical Reports Server (NTRS)
Margetan, Frank J.; Leckey, Cara A.; Barnard, Dan
2012-01-01
The size and shape of a delamination in a multi-layered structure can be estimated in various ways from an ultrasonic pulse/echo image. For example the -6dB contours of measured response provide one simple estimate of the boundary. More sophisticated approaches can be imagined where one adjusts the proposed boundary to bring measured and predicted UT images into optimal agreement. Such approaches require suitable models of the inspection process. In this paper we explore issues pertaining to model-based size estimation for delaminations in carbon fiber reinforced laminates. In particular we consider the influence on sizing when the delamination is non-planar or partially transmitting in certain regions. Two models for predicting broadband sonic time-domain responses are considered: (1) a fast "simple" model using paraxial beam expansions and Kirchhoff and phase-screen approximations; and (2) the more exact (but computationally intensive) 3D elastodynamic finite integration technique (EFIT). Model-to-model and model-to experiment comparisons are made for delaminations in uniaxial composite plates, and the simple model is then used to critique the -6dB rule for delamination sizing.
Liu, Tianyi; Nie, Xiaolu; Wu, Zehao; Zhang, Ying; Feng, Guoshuang; Cai, Siyu; Lv, Yaqi; Peng, Xiaoxia
2017-12-29
Different confounder adjustment strategies were used to estimate odds ratios (ORs) in case-control study, i.e. how many confounders original studies adjusted and what the variables are. This secondary data analysis is aimed to detect whether there are potential biases caused by difference of confounding factor adjustment strategies in case-control study, and whether such bias would impact the summary effect size of meta-analysis. We included all meta-analyses that focused on the association between breast cancer and passive smoking among non-smoking women, as well as each original case-control studies included in these meta-analyses. The relative deviations (RDs) of each original study were calculated to detect how magnitude the adjustment would impact the estimation of ORs, compared with crude ORs. At the same time, a scatter diagram was sketched to describe the distribution of adjusted ORs with different number of adjusted confounders. Substantial inconsistency existed in meta-analysis of case-control studies, which would influence the precision of the summary effect size. First, mixed unadjusted and adjusted ORs were used to combine individual OR in majority of meta-analysis. Second, original studies with different adjustment strategies of confounders were combined, i.e. the number of adjusted confounders and different factors being adjusted in each original study. Third, adjustment did not make the effect size of original studies trend to constringency, which suggested that model fitting might have failed to correct the systematic error caused by confounding. The heterogeneity of confounder adjustment strategies in case-control studies may lead to further bias for summary effect size in meta-analyses, especially for weak or medium associations so that the direction of causal inference would be even reversed. Therefore, further methodological researches are needed, referring to the assessment of confounder adjustment strategies, as well as how to take this kind of bias into consideration when drawing conclusion based on summary estimation of meta-analyses.
A new method for the adjustment of neochordal length: the adjustable slip knot technique.
Yano, Mitsuhiro; Sakaguchi, Syuuhei; Furukawa, Kohji; Nakamura, Eisaku
2015-08-01
The use of expanded polytetrafluoroethylene (ePTFE) sutures for the correction of mitral valve prolapse has become a standardized procedure. Adjustment of neochordal length is crucial to the efficacy of this technique. Various methods have been described for this purpose; however, the fine adjustment of neochordal length is technically challenging. We describe a simple and effective technique for the implantation of neochordae, which we have termed the 'adjustable slip knot technique'. The first step of this technique is reinforcement of the papillary muscle by a Teflon pledget with or without polytetrafluoroethylene (CV-4) loops. The second step is the formation of a neochordal loop by introducing an ePTFE suture between the affected mitral leaflet and the papillary muscle or ePTFE loops. The third step is the adjustment of the length of neochordae. The formation of a slip knot in one arm of the ePTFE suture is the pivot of this technique. The neochordal loop can be constricted by the application of tension to one arm of the suture. We applied this technique in 5 patients with satisfactory results. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Berry, J.; Nesbit, M.; Saberi, S.; Petridis, H.
2014-01-01
Aim The aim of this study was to identify the communication methods and production techniques used by dentists and dental technicians for the fabrication of fixed prostheses within the UK from the dental technicians' perspective. This second paper reports on the production techniques utilised. Materials and methods Seven hundred and eighty-two online questionnaires were distributed to the Dental Laboratories Association membership and included a broad range of topics, such as demographics, impression disinfection and suitability, and various production techniques. Settings were managed in order to ensure anonymity of respondents. Statistical analysis was undertaken to test the influence of various demographic variables such as the source of information, the location, and the size of the dental laboratory. Results The number of completed responses totalled 248 (32% response rate). Ninety percent of the respondents were based in England and the majority of dental laboratories were categorised as small sized (working with up to 25 dentists). Concerns were raised regarding inadequate disinfection protocols between dentists and dental laboratories and the poor quality of master impressions. Full arch plastic trays were the most popular impression tray used by dentists in the fabrication of crowns (61%) and bridgework (68%). The majority (89%) of jaw registration records were considered inaccurate. Forty-four percent of dental laboratories preferred using semi-adjustable articulators. Axial and occlusal under-preparation of abutment teeth was reported as an issue in about 25% of cases. Base metal alloy was the most (52%) commonly used alloy material. Metal-ceramic crowns were the most popular choice for anterior (69%) and posterior (70%) cases. The various factors considered did not have any statistically significant effect on the answers provided. The only notable exception was the fact that more methods of communicating the size and shape of crowns were utilised for large laboratories. Conclusion This study suggests that there are continuing issues in the production techniques utilised between dentists and dental laboratories. PMID:25257017
An Efficient Adaptive Window Size Selection Method for Improving Spectrogram Visualization.
Nisar, Shibli; Khan, Omar Usman; Tariq, Muhammad
2016-01-01
Short Time Fourier Transform (STFT) is an important technique for the time-frequency analysis of a time varying signal. The basic approach behind it involves the application of a Fast Fourier Transform (FFT) to a signal multiplied with an appropriate window function with fixed resolution. The selection of an appropriate window size is difficult when no background information about the input signal is known. In this paper, a novel empirical model is proposed that adaptively adjusts the window size for a narrow band-signal using spectrum sensing technique. For wide-band signals, where a fixed time-frequency resolution is undesirable, the approach adapts the constant Q transform (CQT). Unlike the STFT, the CQT provides a varying time-frequency resolution. This results in a high spectral resolution at low frequencies and high temporal resolution at high frequencies. In this paper, a simple but effective switching framework is provided between both STFT and CQT. The proposed method also allows for the dynamic construction of a filter bank according to user-defined parameters. This helps in reducing redundant entries in the filter bank. Results obtained from the proposed method not only improve the spectrogram visualization but also reduce the computation cost and achieves 87.71% of the appropriate window length selection.
The quality mammographic image. A review of its components.
Rickard, M T
1989-11-01
Seven major factors resulting in a quality or high contrast and high resolution mammographic image have been discussed. The following is a summary of their key features: 1) Dedicated mammographic equipment. --Molybdenum target material --Molybdenum filter, beryllium window --Low kVp usage, in range of 24 to 30 --Routine contact mammography performed at 25 kVp --Slightly lower kVp for coned compression --Slightly higher kVp for microfocus magnification 2) Film density --Phototimer with adjustable position --Calibration of phototimer to optimal optical density of approx. 1.4 over full kVp range 3) Breast Compression --General and focal (coned compression). --Essential to achieve proper contrast, resolution and breast immobility. --Foot controls preferable. 4) Focal Spot. --Size recommendation for contact work 0.3 mm. --Minimum power output of 100 mA at 25 kVp desirable to avoid movement blurring in contact grid work. --Size recommendation for magnification work 0.1 mm. 5) Grid. --Usage recommended as routine in all but magnification work. 6) Film-screen Combination. --High contrast--high speed film. --High resolution screen. --Specifically designed cassette for close film-screen contact and low radiation absorption. --Use of faster screens for magnification techniques. 7) Dedicated processing. --Increased developing time--40 to 45 seconds. --Increased developer temperature--35 to 38 degrees. --Adjusted replenishment rate and dryer temperature. All seven factors contributing to image contrast and resolution affect radiation dosage to the breast. The risk of increased dosage associated with the use of various techniques needs to be balanced against the risks of incorrect diagnosis associated with their non-use.(ABSTRACT TRUNCATED AT 250 WORDS)
Rahman, A T M Mijanur; Lee, Seung Ju; Jung, Seung Won
2015-12-28
A comparative study was conducted to evaluate precision and accuracy in controlling the temperature dependence of encapsulated microbial time-temperature integrators (TTIs) developed using two different emulsification techniques. Weissela cibaria CIFP 009 cells, immobilized within 2% Na-alginate gel microbeads using homogenization (5,000, 7,000, and 10,000 rpm) and Shirasu porous glass (SPG) membrane technologies (10 μm), were applied to microbial TTIs. The prepared micobeads were characterized with respect to their size, size distribution, shape and morphology, entrapment efficiency, and bead production yield. Additionally, fermentation process parameters including growth rate were investigated. The TTI responses (changes in pH and titratable acidity (TA)) were evaluated as a function of temperature (20°C, 25°C, and 30°C). In comparison with conventional methods, SPG membrane technology was able not only to produce highly uniform, small-sized beads with the narrowest size distribution, but also the bead production yield was found to be nearly 3.0 to 4.5 times higher. However, among the TTIs produced using the homogenization technique, poor linearity (R(2)) in terms of TA was observed for the 5,000 and 7,000 rpm treatments. Consequently, microbeads produced by the SPG membrane and by homogenization at 10,000 rpm were selected for adjusting the temperature dependence. The Ea values of TTIs containing 0.5, 1.0, and 1.5 g microbeads, prepared by SPG membrane and conventional methods, were estimated to be 86.0, 83.5, and 76.6 kJ/mol, and 85.5, 73.5, and 62.2 kJ/mol, respectively. Therefore, microbial TTIs developed using SPG membrane technology are much more efficient in controlling temperature dependence.
[Target volume segmentation of PET images by an iterative method based on threshold value].
Castro, P; Huerga, C; Glaría, L A; Plaza, R; Rodado, S; Marín, M D; Mañas, A; Serrada, A; Núñez, L
2014-01-01
An automatic segmentation method is presented for PET images based on an iterative approximation by threshold value that includes the influence of both lesion size and background present during the acquisition. Optimal threshold values that represent a correct segmentation of volumes were determined based on a PET phantom study that contained different sizes spheres and different known radiation environments. These optimal values were normalized to background and adjusted by regression techniques to a two-variable function: lesion volume and signal-to-background ratio (SBR). This adjustment function was used to build an iterative segmentation method and then, based in this mention, a procedure of automatic delineation was proposed. This procedure was validated on phantom images and its viability was confirmed by retrospectively applying it on two oncology patients. The resulting adjustment function obtained had a linear dependence with the SBR and was inversely proportional and negative with the volume. During the validation of the proposed method, it was found that the volume deviations respect to its real value and CT volume were below 10% and 9%, respectively, except for lesions with a volume below 0.6 ml. The automatic segmentation method proposed can be applied in clinical practice to tumor radiotherapy treatment planning in a simple and reliable way with a precision close to the resolution of PET images. Copyright © 2013 Elsevier España, S.L.U. and SEMNIM. All rights reserved.
A consideration on physical tuning for acoustical coloration in recording studio
NASA Astrophysics Data System (ADS)
Shimizu, Yasushi
2003-04-01
Coloration due to particular architectural shapes and dimension or less surface absorption has been mentioned as an acoustical defect in recording studio. Generally interference among early reflected sounds arriving within 10 ms in delay after the direct sound produces coloration by comb filter effect over mid- and high-frequency sounds. In addition, less absorbed room resonance modes also have been well known as a major component for coloration in low-frequency sounds. Small size in dimension with recording studio, however, creates difficulty in characterization associated with wave acoustics behavior, that make acoustical optimization more difficult than that of concert hall acoustics. There still remains difficulty in evaluating amount of coloration as well as predicting its acoustical characteristics in acoustical modeling and in other words acoustical tuning technique during construction is regarded as important to optimize acoustics appropriately to the function of recording studio. This paper presents a example of coloration by comb filtering effect and less damped room modes in typical post-processing recording studio. And acoustical design and measurement technique will be presented for adjusting timbre due to coloration based on psycho-acoustical performance with binaural hearing and room resonance control with line array resonator adjusted to the particular room modes considered.
Effective doses to patients undergoing thoracic computed tomography examinations.
Huda, W; Scalzetti, E M; Roskopf, M
2000-05-01
The purpose of this study was to investigate how x-ray technique factors and effective doses vary with patient size in chest CT examinations. Technique factors (kVp, mAs, section thickness, and number of sections) were recorded for 44 patients who underwent a routine chest CT examination. Patient weights were recorded together with dimensions and mean Hounsfield unit values obtained from representative axial CT images. The total mass of directly irradiated patient was modeled as a cylinder of water to permit the computation of the mean patient dose and total energy imparted for each chest CT examination. Computed values of energy imparted during the chest CT examination were converted into effective doses taking into account the patient weight. Patient weights ranged from 4.5 to 127 kg, and half the patients in this study were children under 18 years of age. All scans were performed at 120 kVp with a 1 s scan time. The selected tube current showed no correlation with patient weight (r2=0.06), indicating that chest CT examination protocols do not take into account for the size of the patient. Energy imparted increased with increasing patient weight, with values of energy imparted for 10 and 70 kg patients being 85 and 310 mJ, respectively. The effective dose showed an inverse correlation with increasing patient weight, however, with values of effective dose for 10 and 70 kg patients being 9.6 and 5.4 mSv, respectively. Current CT technique factors (kVp/mAs) used to perform chest CT examinations result in relatively high patient doses, which could be reduced by adjusting technique factors based on patient size.
Factor Analysis of the Modified Sexual Adjustment Questionnaire-Male
Wilmoth, Margaret C.; Hanlon, Alexandra L.; Ng, Lit Soo; Bruner, Debra W.
2015-01-01
Background and Purpose The Sexual Adjustment Questionnaire (SAQ) is used in National Cancer Institute–sponsored clinical trials as an outcome measure for sexual functioning. The tool was revised to meet the needs for a clinically useful, theory-based outcome measure for use in both research and clinical settings. This report describes the modifications and validity testing of the modified Sexual Adjustment Questionnaire-Male (mSAQ-Male). Methods This secondary analysis of data from a large Radiation Therapy Oncology Group trial employed principal axis factor analytic techniques in estimating validity of the revised tool. The sample size was 686; most subjects were White, older than the age 60 years, and with a high school education and a Karnofsky performance scale (KPS) score of greater than 90. Results A 16-item, 3-factor solution resulted from the factor analysis. The mSAQ-Male was also found to be sensitive to changes in physical sexual functioning as measured by the KPS. Conclusion The mSAQ-Male is a valid self-report measure of sexuality that can be used clinically to detect changes in male sexual functioning. PMID:25255676
Controlled morphology and size of curcumin using ultrasound in supercritical CO2 antisolvent.
Jia, Jingfu; Wang, Wucong; Gao, Yahui; Zhao, Yaping
2015-11-01
Controllable morphology and size of crystal materials prepared by using a supercritical antisolvent (SAS) technique is still challenge. In this study, ultrasound was introduced into the SAS process to produce the particles of curcumin, a model compound. The effects of ultrasound power on the particle morphology and size were investigated in the range of 0 and 240 W at three different pressures. The observation of jet flow indicated ultrasound could accelerate the mixing speed between the liquid solution and the CO2, and thus reduced the gaseous region and the local saturation gradient. Mixed polymorphic and uniform particles of the curcumin were produced at a low and high mixing speed, respectively, confirmed by scanning electron microscopy. The needle- or rod-like particle, irregular lumpy particle and nano spherical particle were generated with the increase of the ultrasound power, attributed to the changes of the degree of supersaturation. Therefore, the ultrasound can be potentially applied to adjust the morphology and size of the crystal materials in supercritical CO2 antisolvent. Copyright © 2015 Elsevier B.V. All rights reserved.
Busatto, Carlos; Pesoa, Juan; Helbling, Ignacio; Luna, Julio; Estenoz, Diana
2018-01-30
Poly(lactic-co-glycolic acid) (PLGA) microparticles containing progesterone were prepared by the solvent extraction/evaporation and microfluidic techniques. Microparticles were characterized by their size distribution, encapsulation efficiency, morphology and thermal properties. The effect of particle size, polydispersity and polymer degradation on the in vitro release of the hormone was studied. A triphasic release profile was observed for larger microparticles, while smaller microspheres showed a biphasic release profile. This behavior is related to the fact that complete drug release was achieved in a few days for smaller microparticles, during which polymer degradation effects are still negligible. A mathematical model was developed that predicts the progesterone release profiles from different-sized PLGA microspheres. The model takes into account both the dissolution and diffusion of the drug in the polymeric matrix as well as the autocatalytic effect of polymer degradation. The model was adjusted and validated with novel experimental data. Simulation results are in very good agreement with experimental results. Copyright © 2017 Elsevier B.V. All rights reserved.
İriboz, Emre; Bayraktar, Koral; Türkaydın, Dilek; Tarçın, Bilge
2015-03-01
We compared the apical extrusion of sodium hypochlorite delivered with a 27-G needle, self-adjusting file (SAF), passive ultrasonic irrigation, or the EndoVac system (SybronEndo, Orange, CA) during the instrumentation and final irrigation of root canals. Matched paired single-canal teeth were divided into 8 groups. The experimental groups were needle irrigation size #30 (NI30) and #50 (NI50), SAF size #30 (SAF30) and #50 (SAF50), passive ultrasonic irrigation size #30 (PUI30) and #50 (PUI50), and EndoVac size #30 (EV30) and #50 (EV50). Teeth were embedded in 0.2% agarose gel (pH = 7.4) containing 1 mL 0.1% m-Cresol purple (Sigma-Aldrich, St Louis, MO), which changes color at a pH level of 9.0. Root canals were irrigated with sodium hypochlorite and EDTA using 4 different techniques, and the amount of irrigant was controlled. Standardized digital photographs were taken 20 minutes after the first irrigant was used and were analyzed to determine the amount of extrusion (expressed as a percentage of total pixels). The amounts of apical extrusion obtained in the NI30, NI50, SAF30, SAF50, PUI30, PUI50, EV30, and EV50 groups were 30% (3/10), 50% (5/10), 20% (2/10), 70% (7/10), 40% (4/10), 40% (4/10), 10% (1/10), and 10% (1/10), respectively. The overall extrusion frequency, regardless of the apical preparation size, was 40% (8/20) for needle, 45% (9/20) for SAF, 40% (8/20) for ultrasonic irrigation, and 10% (2/20) for EndoVac. Although the SAF group showed more extrusion, the percentage of pixels was significantly higher in the needle irrigation group (P < .01). The EndoVac group showed significantly lower extrusion values than the other techniques in terms of the number of teeth and pixels (P < .05 and P < .01, respectively). The risk of apical extrusion is significantly lower with the EndoVac in comparison with the 3 other techniques. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carpenter, John S.; Brown, Donald William; Clausen, Bjorn
Additive manufacturing (AM), or three-dimensional (3D) printing as it is more commonly known, is defined as the process of joining materials and creating objects by melting, sintering, or fusing material in a layer-by-layer fashion coordinated via 3D model data.1 Subtractive, or traditional, manufacturing methodologies often consist of machining/removing material—like a sculptor—or forming material through the application of pressure—like a potter. Conversely, in an AM process, material is added in individual volume elements and built up in a way similar to interlocking building blocks, but with volume elements that are typically the size of a grain of sand. The additive processmore » often involves less waste when compared to subtractive techniques because material is only added when and where it is needed. Adjustments to the final structure are relatively straightforward and can be simply achieved by adjusting the 3D computer model. This makes the technology much more flexible than traditional, subtractive techniques where new tooling or forming equipment is usually needed to accommodate design changes. Also, the AM processes are beneficial because they permit the fabrication of unique geometries, such as miniaturized metal lattice structures, that cannot be achieved using traditional techniques. An example of a metal lattice structure is the Eiffel Tower with its Figure 1. Schematic showing required linkages between experimental and modeling thrusts in order to achieve science-based qualification. Arrows showing linkages are color-coded according to the funded projects listed. geometric, interconnecting struts that reduce the overall weight of the tower while maintaining strength. In AM, the size of the struts can be made smaller than the diameter of a human hair, which further reduces weight while maintaining strength—a combination of properties that can benefit many applications.« less
Carpenter, John S.; Brown, Donald William; Clausen, Bjorn; ...
2017-03-01
Additive manufacturing (AM), or three-dimensional (3D) printing as it is more commonly known, is defined as the process of joining materials and creating objects by melting, sintering, or fusing material in a layer-by-layer fashion coordinated via 3D model data.1 Subtractive, or traditional, manufacturing methodologies often consist of machining/removing material—like a sculptor—or forming material through the application of pressure—like a potter. Conversely, in an AM process, material is added in individual volume elements and built up in a way similar to interlocking building blocks, but with volume elements that are typically the size of a grain of sand. The additive processmore » often involves less waste when compared to subtractive techniques because material is only added when and where it is needed. Adjustments to the final structure are relatively straightforward and can be simply achieved by adjusting the 3D computer model. This makes the technology much more flexible than traditional, subtractive techniques where new tooling or forming equipment is usually needed to accommodate design changes. Also, the AM processes are beneficial because they permit the fabrication of unique geometries, such as miniaturized metal lattice structures, that cannot be achieved using traditional techniques. An example of a metal lattice structure is the Eiffel Tower with its Figure 1. Schematic showing required linkages between experimental and modeling thrusts in order to achieve science-based qualification. Arrows showing linkages are color-coded according to the funded projects listed. geometric, interconnecting struts that reduce the overall weight of the tower while maintaining strength. In AM, the size of the struts can be made smaller than the diameter of a human hair, which further reduces weight while maintaining strength—a combination of properties that can benefit many applications.« less
Wu, Qianru; Lu, Jiping; Liu, Changmeng; Fan, Hongli; Shi, Xuezhi; Fu, Jie; Ma, Shuyuan
2017-07-04
Wire arc additive manufacturing (WAAM) technique is a cost-competitive and efficient technology to produce large structure components in industry domains. Mechanical properties are mainly dominated by the microstructure of the components, which is deeply affected by the molten pool size. In this work, to investigate the effect of the molten pool size on microstructure and mechanical properties of the components, a series of Ti-6Al-4V alloy blocks with different width of molten pool (WMP) ranging from 7 mm to 22 mm were deposited by adjusting the wire feed speed (WFS) from 100 cm/min to 500 cm/min. It is interesting to find that the macrostructure changes from columnar grains to equiaxial grains, and then returns to large columnar grains with the increase of WMP, which is mainly caused by the different cooling rates and thermal gradients. Nonetheless, the tensile properties of the components have a tendency to decline with the increase of WMP.
Wu, Qianru; Lu, Jiping; Liu, Changmeng; Fan, Hongli; Shi, Xuezhi; Fu, Jie; Ma, Shuyuan
2017-01-01
Wire arc additive manufacturing (WAAM) technique is a cost-competitive and efficient technology to produce large structure components in industry domains. Mechanical properties are mainly dominated by the microstructure of the components, which is deeply affected by the molten pool size. In this work, to investigate the effect of the molten pool size on microstructure and mechanical properties of the components, a series of Ti-6Al-4V alloy blocks with different width of molten pool (WMP) ranging from 7 mm to 22 mm were deposited by adjusting the wire feed speed (WFS) from 100 cm/min to 500 cm/min. It is interesting to find that the macrostructure changes from columnar grains to equiaxial grains, and then returns to large columnar grains with the increase of WMP, which is mainly caused by the different cooling rates and thermal gradients. Nonetheless, the tensile properties of the components have a tendency to decline with the increase of WMP. PMID:28773107
Vinyl monomers-induced synthesis of polyvinyl alcohol-stabilized selenium nanoparticles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shah, Chetan P.; Singh, Krishan K.; Kumar, Manmohan, E-mail: manmoku@barc.gov.in
2010-01-15
A simple wet chemical method has been developed to synthesize selenium nanoparticles (size 100-200 nm), by reaction of sodium selenosulphate precursor with different vinyl monomers, such as acrylamide, N,N'-dimethylene bis acrylamide, methyl methacrylate, sodium acrylate, etc., in aqueous medium, under ambient conditions. Polyvinyl alcohol has been used to stabilize the selenium nanoparticles. Average size of the synthesized selenium nanoparticles can be controlled by adjusting concentration of both the precursors and the stabilizer. Rate of the reaction as well as size of the resultant selenium nanoparticles have been correlated with the functional groups of the different monomers. UV-vis optical absorption spectroscopy,more » X-ray diffraction, energy dispersive X-rays, differential scanning calorimetry, atomic force microscopy, scanning electron microscopy and transmission electron microscopy techniques have been employed to characterize the synthesized selenium nanoparticles. Gas chromatographic analysis of the reaction mixture established the non-catalytic role of the vinyl monomers, which were found to be consumed during the course of the reaction.« less
TH-C-12A-03: Development of Expanded Field Irradiation Technique with Gimbaled X-Ray Head
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ono, T; Miyabe, Y; Yamada, M
2014-06-15
Purpose: The Vero4DRT has a maximum field size of 150×150 mm{sup 2}. The purposes of this study were to develop an expanded field irradiation technique using a unique gimbaled x-ray head of Vero4DRT and to evaluate its dosimetric characteristic. Methods: The expanded field irradiation consisted of four separate fields with 2.39 degree gimbal rotation around orthogonal two axes. The central beam axis for each field shifted 40 mm from the isocenter for longitudinal and lateral directions, and thus, the field size was expanded up to 230×230 mm{sup 2}. Adjacent region were created at the isocenter (center-adjacent expanded-field) and 20 mmmore » from isocenter (offadjacent expanded-field). To create flat dose distribution in the combined piecewise-fields, the overlapping and gaps regions on the isocenter plane were adjusted with the gimbal rotating and the MLC. To evaluate dosimetric characteristic of the expanded-field, films inserted in water-equivalent phantoms at 50, 100 and 150 mm depth were irradiated and the field size, penumbra, flatness and symmetry were analyzed.In addition, the expandedfield irradiation technique was applied to IMRT. A head and neck IMRT field, which was planned for the conventional linac (Varian Clinac iX), was reproduced with the expanded-field of the Vero4DRT. The simulated dose distribution for the expanded IMRT field was compared to the measured dose distribution. Results: The field size, penumbra, flatness and symmetry of center- and off- adjacent expanded-fields were 230.2–232.1 mm, 7.8–10.7 mm, 2.3–6.5% and –0.5–0.4% at 100 mm depth. The 82.1% area of the expanded IMRT dose distribution was within 5% difference between measurement and simulation, which was analyzed upper 50% dose area, and the 3%/3 mm gamma pass rate was 98.4%. Conclusions: The expandedfield technique was developed using the gimbaled x-ray head. To extend applied targets, such as whole breast irradiations or head and neck IMRT, the expanded-field technique would be effective.« less
NASA Astrophysics Data System (ADS)
Darwish, Ayman M.; Eisa, Wael H.; Shabaka, Ali A.; Talaat, Mohamed H.
2016-01-01
Pulsed laser ablation in a liquid medium is a promising technique as compared to the other synthetic methods to synthesize different materials in nanoscale form. The laser parameters (e.g., wavelength, pulse width, fluence, and repetition frequency) and liquid medium (e.g., aqueous/nonaqueous liquid or solution with surfactant) were tightly controlled during and after the ablation process. By optimizing these parameters, the particle size and distribution of materials can be adjusted. The UV-vis absorption spectra and weight changes of targets were used for the characterization and comparison of products.
Curvature aided long range propagation of short laser pulses in the atmosphere
NASA Astrophysics Data System (ADS)
Yedierler, Burak
2013-03-01
The pre-filamentation regime of propagation of a short and intense laser pulse in the atmosphere is considered. Spatiotemporal self-focusing dynamics of the laser beam are investigated by calculating the coupled differential equations for spot size, pulse length, phase, curvature, and chirp functions of a Gaussian laser pulse via a variational technique. The effect of initial curvature parameter on the propagation of the laser pulse is taken into consideration. A method relying on the adjustment of the initial curvature parameter can expand the filamentation distance of a laser beam of given power and chirp is proposed.
Design of a setup for 252Cf neutron source for storage and analysis purpose
NASA Astrophysics Data System (ADS)
Hei, Daqian; Zhuang, Haocheng; Jia, Wenbao; Cheng, Can; Jiang, Zhou; Wang, Hongtao; Chen, Da
2016-11-01
252Cf is a reliable isotopic neutron source and widely used in the prompt gamma ray neutron activation analysis (PGNAA) technique. A cylindrical barrel made by polymethyl methacrylate contained with the boric acid solution was designed for storage and application of a 5 μg 252Cf neutron source. The size of the setup was optimized with Monte Carlo code. The experiments were performed and the results showed the doses were reduced with the setup and less than the allowable limit. The intensity and collimating radius of the neutron beam could also be adjusted through different collimator.
Guo, Shuang; Zhu, Chenqi; Gao-Yang, Yaya; Qiu, Bailing; Wu, Di; Liang, Qihui; He, Jiayuan; Han, Nanyin
2016-02-01
Gravitational field-flow fractionation is the simplest field-flow fractionation technique in terms of principle and operation. The earth' s gravity is its external field. Different sized particles are injected into a thin channel and carried by carrier fluid. The different velocities of the carrier liquid in different places results in a size-based separation. A gravitational field-flow fractionation (GrFFF) instrument was designed and constructed. Two kinds of polystyrene (PS) particles with different sizes (20 µm and 6 µm) were chosen as model particles. In this work, the separation of the sample was achieved by changing the concentration of NaN3, the percentage of mixed surfactant in the carrier liquid and the flow rate of carrier liquid. Six levels were set for each factor. The effects of these three factors on the retention ratio (R) and plate height (H) of the PS particles were investigated. It was found that R increased and H decreased with increasing particle size. On the other hand, the R and H increased with increasing flow rate. The R and H also increased with increasing NaN3 concentration. The reason was that the electrostatic repulsive force between the particles and the glass channel wall increased. The force allowed the samples approach closer to the channel wall. The results showed that the resolution and retention time can be improved by adjusting the experimental conditions. These results can provide important values to the further applications of GrFFF technique.
Study on growth techniques and macro defects of large-size Nd:YAG laser crystal
NASA Astrophysics Data System (ADS)
Quan, Jiliang; Yang, Xin; Yang, Mingming; Ma, Decai; Huang, Jinqiang; Zhu, Yunzhong; Wang, Biao
2018-02-01
Large-size neodymium-doped yttrium aluminum garnet (Nd:YAG) single crystals were grown by the Czochralski method. The extinction ratio and wavefront distortion of the crystal were tested to determine the optical homogeneity. Moreover, under different growth conditions, the macro defects of inclusion, striations, and cracking in the as-grown Nd:YAG crystals were analyzed. Specifically, the inclusion defects were characterized using scanning electron microscopy and energy dispersive spectroscopy. The stresses of growth striations and cracking were studied via a parallel plane polariscope. These results demonstrate that improper growth parameters and temperature fields can enhance defects significantly. Thus, by adjusting the growth parameters and optimizing the thermal environment, high-optical-quality Nd:YAG crystals with a diameter of 80 mm and a total length of 400 mm have been obtained successfully.
Variable aperture-based ptychographical iterative engine method
NASA Astrophysics Data System (ADS)
Sun, Aihui; Kong, Yan; Meng, Xin; He, Xiaoliang; Du, Ruijun; Jiang, Zhilong; Liu, Fei; Xue, Liang; Wang, Shouyu; Liu, Cheng
2018-02-01
A variable aperture-based ptychographical iterative engine (vaPIE) is demonstrated both numerically and experimentally to reconstruct the sample phase and amplitude rapidly. By adjusting the size of a tiny aperture under the illumination of a parallel light beam to change the illumination on the sample step by step and recording the corresponding diffraction patterns sequentially, both the sample phase and amplitude can be faithfully reconstructed with a modified ptychographical iterative engine (PIE) algorithm. Since many fewer diffraction patterns are required than in common PIE and the shape, the size, and the position of the aperture need not to be known exactly, this proposed vaPIE method remarkably reduces the data acquisition time and makes PIE less dependent on the mechanical accuracy of the translation stage; therefore, the proposed technique can be potentially applied for various scientific researches.
Cross, J; Elender, F; Barton, G; Clark, A; Shepstone, L; Blyth, A; Bachmann, M; Harvey, I
2010-05-01
To estimate the effect, if any, of manual chest physiotherapy (MCP) administered to patients hospitalised with chronic obstructive pulmonary disease (COPD) exacerbation on both disease-specific and generic health-related quality of life. To compare the health service costs for those receiving and not receiving MCP. A pragmatic, randomised controlled trial powered for equivalence. It was not possible to blind participants, clinicians or research staff to study arm allocation during the intervention. Four UK hospitals in Norwich, Great Yarmouth, King's Lynn and Liverpool. 526 participants aged 34-91 years were recruited between November 2005 and April 2008; of these, 372 provided evaluable data for the primary outcome. All persons hospitalised with COPD exacerbation and evidence of sputum production on examination were eligible for the trial providing there were no contraindications to performing MCP. Participants were allocated to either MCP or no MCP on an intention-to-treat (ITT) basis. However, active cycle of breathing techniques (ACBT) was used in both arms. Participants allocated to the intervention were guided to perform ACBT while the physiotherapist delivered MCP. Participants allocated to the control arm received instruction on ACBT only. The primary outcome was COPD-specific quality of life, measured using the St George's Respiratory Questionnaire (SGRQ) at 6 months post randomisation. The European Quality of Life-5 Dimensions (EQ-5D) questionnaire was used to calculate the quality-adjusted life-year (QALY) gain associated with MCP compared with no MCP. Secondary physiological outcome measures were also used. Of the 526 participants, 261 were allocated to MCP and 264 to control, with 186 participants evaluable in each arm. ITT analyses indicated no significant difference at 6 months post randomisation in total SGRQ score [adjusted effect size (no MCP - MCP) 0.03 (95% confidence interval, CI -0.14 to 0.19)], SGRQ symptom score [adjusted effect size 0.04 (95% CI -0.15 to 0.23)], SGRQ activity score [adjusted effect size -0.02 (95% CI -0.20 to 0.16)] or SGRQ impact score [adjusted effect size 0.02 (95% CI -0.15 to 0.18)]. The imputed ITT and per-protocol results were similar. No significant differences were observed in any of the outcome measures or subgroup analyses. Compared with no MCP, employing MCP was associated with a slight loss in quality of life (0.001 QALY loss) but lower health service costs (cost saving of 410.79 pounds). Based on these estimates, at a cost-effectiveness threshold of lambda = 20,000 pounds per QALY, MCP would constitute a cost-effective use of resources (net benefit = 376.14 pounds). There was, however, a high level of uncertainty associated with these results and it is possible that the lower health service costs could have been due to other factors. In terms of longer-term quality of life the use of MCP did not appear to affect outcome. However, this does not mean that MCP is of no therapeutic value to patients with COPD in specific circumstances. Although the cost-effectiveness analysis suggested that its use was cost-effective, much uncertainty was associated with this finding and it would be difficult to justify providing MCP therapy on the basis of cost-effectiveness alone. Future research should include evaluation of MCP for patients with COPD producing high volumes of sputum, and an evaluation of the effectiveness of ACBT in COPD exacerbation. Current Controlled Trials ISRCTN13825248.
Loreto-Gómez, Carmen; Farías, Paulina; Moreno-Macías, Hortensia; Romano-Riquer, S P; Riojas-Rodríguez, Horacio
2017-10-01
There is no consensus on which anogenital distance (AGD) variant to use and how to adjust it by body size in humans. This study quantitatively evaluated AGD variants and body size adjustments to determine which would be the best choice. AGD variants, height, and weight were measured on five occasions during the first year of life of 307 infants. The ratio of anoscrotal distance (ASD) in boys and anofourchette distance (AFD) in girls increased from 1.9 at birth to 2.3 at 12 months of age. Each AGD variant was divided by each body size variable to generate different indices. Such indices were standardized to make them comparable when analyzing their performance through mixed models. ASD and AFD adjusted by height generated precise (p<0.05) AGD indices: 0.4-0.5 and 0.2, respectively. Results suggest that the best body size adjustment for all AGD variants in the first year of life is height. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, L.-P.; Ochoa-Rodríguez, S.; Onof, C.; Willems, P.
2015-09-01
Gauge-based radar rainfall adjustment techniques have been widely used to improve the applicability of radar rainfall estimates to large-scale hydrological modelling. However, their use for urban hydrological applications is limited as they were mostly developed based upon Gaussian approximations and therefore tend to smooth off so-called "singularities" (features of a non-Gaussian field) that can be observed in the fine-scale rainfall structure. Overlooking the singularities could be critical, given that their distribution is highly consistent with that of local extreme magnitudes. This deficiency may cause large errors in the subsequent urban hydrological modelling. To address this limitation and improve the applicability of adjustment techniques at urban scales, a method is proposed herein which incorporates a local singularity analysis into existing adjustment techniques and allows the preservation of the singularity structures throughout the adjustment process. In this paper the proposed singularity analysis is incorporated into the Bayesian merging technique and the performance of the resulting singularity-sensitive method is compared with that of the original Bayesian (non singularity-sensitive) technique and the commonly used mean field bias adjustment. This test is conducted using as case study four storm events observed in the Portobello catchment (53 km2) (Edinburgh, UK) during 2011 and for which radar estimates, dense rain gauge and sewer flow records, as well as a recently calibrated urban drainage model were available. The results suggest that, in general, the proposed singularity-sensitive method can effectively preserve the non-normality in local rainfall structure, while retaining the ability of the original adjustment techniques to generate nearly unbiased estimates. Moreover, the ability of the singularity-sensitive technique to preserve the non-normality in rainfall estimates often leads to better reproduction of the urban drainage system's dynamics, particularly of peak runoff flows.
Babalola, Stella; Figueroa, Maria-Elena; Krenn, Susan
2017-11-01
Literature abounds with evidence on the effectiveness of individual mass media interventions on contraceptive use and other health behaviors. There have been, however, very few studies summarizing effect sizes of mass media health communication campaigns in sub-Saharan Africa. In this study, we used meta-analytic techniques to pool data from 47 demographic and health surveys conducted between 2005 and 2015 in 31 sub-Saharan African countries and estimate the prevalence of exposure to family planning-related mass media communication. We also estimated the average effect size of exposure to mass media communication after adjusting for endogeneity. We performed meta-regression to assess the moderating role of selected variables on effect size. On average, 44% of women in sub-Saharan Africa were exposed to family planning-related mass media interventions in the year preceding the survey. Overall, exposure was associated with an effect size equivalent to an odds ratio of 1.93. More recent surveys demonstrated smaller effect sizes than earlier ones, while the effects were larger in lower contraceptive prevalence settings than in higher prevalence ones. The findings have implications for designing communication programs, setting expectations about communication impact, and guiding decisions about sample size estimation for mass media evaluation studies.
NASA Astrophysics Data System (ADS)
Shiau, Bo-Wen; Lin, Chien-Hung; Liao, Ying-Yen; Lee, Ya-Rong; Liu, Shih-Hao; Ding, Wei-Cheng; Lee, Jia-Ren
2018-05-01
In this work, the optical properties of Au nanoparticles processed by centrifugation techniques are studied. Most of the literature related to the control of nanoparticle size has focused on different preparation parameters; however, the wide size distribution is commonly an issue for follow-up investigations and further applications. Therefore, we developed a method in which specific-diameter particles can be effectively separated using different centrifugal procedures. The initial nanoparticle solution with a primary absorption peak at 534 nm is separated into discernible resonance wavelengths from 526 to 537 nm, with corresponding particle sizes from 30 to 55 nm. For the atomic force microscopy analysis of nanoparticle size, a dry cetyltrimethylammonium bromide (CTAB) film often covers the particles and interferes with the measurement; thus, CTAB has to be removed. However, if too much CTAB is removed, the surface of the Au nanoparticle becomes unstable, and the particles aggregate. Accordingly, we used UV spectroscopy to monitor the CTAB content; properly adjust the rotational speed and the number of centrifugation stages; and design a method that can effectively remove impurities, avoid clustering, and enable particle size measurement. The usually complicated procedures and high cost of preparation of specific-size Au nanoparticles are greatly simplified and reduced by the convenient extraction process proposed in this work, which would benefit related research and applications.
Arce, Pedro; Lagares, Juan Ignacio
2018-01-25
We have verified the GAMOS/Geant4 simulation model of a 6 MV VARIAN Clinac 2100 C/D linear accelerator by the procedure of adjusting the initial beam parameters to fit the percentage depth dose and cross-profile dose experimental data at different depths in a water phantom. Thanks to the use of a wide range of field sizes, from 2 × 2 cm 2 to 40 × 40 cm 2 , a small phantom voxel size and high statistics, fine precision in the determination of the beam parameters has been achieved. This precision has allowed us to make a thorough study of the different physics models and parameters that Geant4 offers. The three Geant4 electromagnetic physics sets of models, i.e. Standard, Livermore and Penelope, have been compared to the experiment, testing the four different models of angular bremsstrahlung distributions as well as the three available multiple-scattering models, and optimizing the most relevant Geant4 electromagnetic physics parameters. Before the fitting, a comprehensive CPU time optimization has been done, using several of the Geant4 efficiency improvement techniques plus a few more developed in GAMOS.
Using spatial uncertainty to manipulate the size of the attention focus.
Huang, Dan; Xue, Linyan; Wang, Xin; Chen, Yao
2016-09-01
Preferentially processing behaviorally relevant information is vital for primate survival. In visuospatial attention studies, manipulating the spatial extent of attention focus is an important question. Although many studies have claimed to successfully adjust attention field size by either varying the uncertainty about the target location (spatial uncertainty) or adjusting the size of the cue orienting the attention focus, no systematic studies have assessed and compared the effectiveness of these methods. We used a multiple cue paradigm with 2.5° and 7.5° rings centered around a target position to measure the cue size effect, while the spatial uncertainty levels were manipulated by changing the number of cueing positions. We found that spatial uncertainty had a significant impact on reaction time during target detection, while the cue size effect was less robust. We also carefully varied the spatial scope of potential target locations within a small or large region and found that this amount of variation in spatial uncertainty can also significantly influence target detection speed. Our results indicate that adjusting spatial uncertainty is more effective than varying cue size when manipulating attention field size.
Ju, Min-Wook; Kwon, Hyon-Jo; Choi, Seung-Won; Koh, Hyeon-Song; Youm, Jin-Young; Song, Shi-Hun
2015-01-01
Objective Brain atrophy and subdural hygroma were well known factors that enlarge the subdural space, which induced formation of chronic subdural hematoma (CSDH). Thus, we identified the subdural volume that could be used to predict the rate of future CSDH after head trauma using a computed tomography (CT) volumetric analysis. Methods A single institution case-control study was conducted involving 1,186 patients who visited our hospital after head trauma from January 1, 2010 to December 31, 2014. Fifty-one patients with delayed CSDH were identified, and 50 patients with age and sex matched for control. Intracranial volume (ICV), the brain parenchyme, and the subdural space were segmented using CT image-based software. To adjust for variations in head size, volume ratios were assessed as a percentage of ICV [brain volume index (BVI), subdural volume index (SVI)]. The maximum depth of the subdural space on both sides was used to estimate the SVI. Results Before adjusting for cranium size, brain volume tended to be smaller, and subdural space volume was significantly larger in the CSDH group (p=0.138, p=0.021, respectively). The BVI and SVI were significantly different (p=0.003, p=0.001, respectively). SVI [area under the curve (AUC), 77.3%; p=0.008] was a more reliable technique for predicting CSDH than BVI (AUC, 68.1%; p=0.001). Bilateral subdural depth (sum of subdural depth on both sides) increased linearly with SVI (p<0.0001). Conclusion Subdural space volume was significantly larger in CSDH groups. SVI was a more reliable technique for predicting CSDH. Bilateral subdural depth was useful to measure SVI. PMID:27169071
Ju, Min-Wook; Kim, Seon-Hwan; Kwon, Hyon-Jo; Choi, Seung-Won; Koh, Hyeon-Song; Youm, Jin-Young; Song, Shi-Hun
2015-10-01
Brain atrophy and subdural hygroma were well known factors that enlarge the subdural space, which induced formation of chronic subdural hematoma (CSDH). Thus, we identified the subdural volume that could be used to predict the rate of future CSDH after head trauma using a computed tomography (CT) volumetric analysis. A single institution case-control study was conducted involving 1,186 patients who visited our hospital after head trauma from January 1, 2010 to December 31, 2014. Fifty-one patients with delayed CSDH were identified, and 50 patients with age and sex matched for control. Intracranial volume (ICV), the brain parenchyme, and the subdural space were segmented using CT image-based software. To adjust for variations in head size, volume ratios were assessed as a percentage of ICV [brain volume index (BVI), subdural volume index (SVI)]. The maximum depth of the subdural space on both sides was used to estimate the SVI. Before adjusting for cranium size, brain volume tended to be smaller, and subdural space volume was significantly larger in the CSDH group (p=0.138, p=0.021, respectively). The BVI and SVI were significantly different (p=0.003, p=0.001, respectively). SVI [area under the curve (AUC), 77.3%; p=0.008] was a more reliable technique for predicting CSDH than BVI (AUC, 68.1%; p=0.001). Bilateral subdural depth (sum of subdural depth on both sides) increased linearly with SVI (p<0.0001). Subdural space volume was significantly larger in CSDH groups. SVI was a more reliable technique for predicting CSDH. Bilateral subdural depth was useful to measure SVI.
McCormack, V A; dos Santos Silva, I; De Stavola, B L; Mohsen, R; Leon, D A; Lithell, H O
2003-02-01
To investigate whether size at birth and rate of fetal growth influence the risk of breast cancer in adulthood. Cohort identified from detailed birth records, with 97% follow up. Uppsala Academic Hospital, Sweden. 5358 singleton females born during 1915-29, alive and traced to the 1960 census. Incidence of breast cancer before (at age <50 years) and after (> or = 50 years) the menopause. Size at birth was positively associated with rates of breast cancer in premenopausal women. In women who weighed > or =4000 g at birth rates of breast cancer were 3.5 times (95% confidence interval 1.3 to 9.3) those in women of similar gestational age who weighed <3000 g at birth. Rates in women in the top fifths of the distributions of birth length and head circumference were 3.4 (1.5 to 7.9) and 4.0 (1.6 to 10.0) times those in the lowest fifths (adjusted for gestational age). The effect of birth weight disappeared after adjustment for birth length or head circumference, whereas the effects of birth length and head circumference remained significant after adjustment for birth weight. For a given size at birth, gestational age was inversely associated with risk (P=0.03 for linear trend). Adjustment for markers of adult risk factors did not affect these findings. Birth size was not associated with rates of breast cancer in postmenopausal women. Size at birth, particularly length and head circumference, is associated with risk of breast cancer in women aged <50 years. Fetal growth rate, as measured by birth size adjusted for gestational age, rather than size at birth may be the aetiologically relevant factor in premenopausal breast cancer.
Song, Rui; Kosorok, Michael R.; Cai, Jianwen
2009-01-01
Summary Recurrent events data are frequently encountered in clinical trials. This article develops robust covariate-adjusted log-rank statistics applied to recurrent events data with arbitrary numbers of events under independent censoring and the corresponding sample size formula. The proposed log-rank tests are robust with respect to different data-generating processes and are adjusted for predictive covariates. It reduces to the Kong and Slud (1997, Biometrika 84, 847–862) setting in the case of a single event. The sample size formula is derived based on the asymptotic normality of the covariate-adjusted log-rank statistics under certain local alternatives and a working model for baseline covariates in the recurrent event data context. When the effect size is small and the baseline covariates do not contain significant information about event times, it reduces to the same form as that of Schoenfeld (1983, Biometrics 39, 499–503) for cases of a single event or independent event times within a subject. We carry out simulations to study the control of type I error and the comparison of powers between several methods in finite samples. The proposed sample size formula is illustrated using data from an rhDNase study. PMID:18162107
7 CFR 3565.203 - Restrictions on rents.
Code of Federal Regulations, 2010 CFR
2010-01-01
... equal to 30 percent of 115 percent of area median income, adjusted for family size. In addition, on an annual basis, the average rent for a project, taking into account all individual unit rents, must not exceed 30 percent of 100 percent of area median income, adjusted for family size. ...
7 CFR 3565.203 - Restrictions on rents.
Code of Federal Regulations, 2011 CFR
2011-01-01
... equal to 30 percent of 115 percent of area median income, adjusted for family size. In addition, on an annual basis, the average rent for a project, taking into account all individual unit rents, must not exceed 30 percent of 100 percent of area median income, adjusted for family size. ...
Evaluation of rock classifications at B. C. Rail tumbler ridge tunnels
NASA Astrophysics Data System (ADS)
Kaiser, Peter K.; Mackay, C.; Gale, A. D.
1986-10-01
Construction of four single track railway tunnels through sedimentary rocks in central British Columbia, Canada, provided an excellent opportunity to compare various rock mass classification systems and to evaluate their applicability to the local geology. The tunnels were excavated by conventional drilling and blasting techniques and supported primarily with rock bolts and shotcrete, and with steel sets in some sections. After a brief project description including tunnel construction techniques, local geology and groundwater conditions, the data collection and filed mapping procedure is reviewed. Four rock mass classification systems ( RQD, RSR, RMR, Q) for empirical tunnel design are reviewed and relevant factors for the data interpretation are discussed. In comparing and evaluating the performance of these classification systems three aspects received special attention. The tunnel support predicted by the various systems was compared to the support installed, a unique correlation between the two most useful and most frequently applied classifications, the RMR and Q systems, was established and assessed, and finally, the non-support limit and size effect were evaluated. It is concluded that the Q-system best predicted the required tunnel support and that the RMR was only adequate after adjustment for the influence of opening size. Correction equations for opening size effects are presented for the RMR system. The RSR and RQD systems are not recommended for empirical tunnel design.
pH Sensitive Microcapsules for Delivery of Corrosion Inhibitors
NASA Technical Reports Server (NTRS)
Li, Wenyan; Calle, Luz M.
2006-01-01
A considerable number of corrosion problems can be solved by coatings. However, even the best protective coatings can fail by allowing the slow diffusion of oxygen and moisture to the metal surface. Corrosion accelerates when a coating delaminates. Often, the problems start when microscopic nicks or pits on the surface develop during manufacturing or through wear and tear. This problem can be solved by the incorporation of a self-healing function into the coating. Several new concepts are currently under development to incorporate this function into a coating. Conductive polymers, nanoparticles, and microcapsules are used to release corrosion-inhibiting ions at a defect site. The objective of this investigation is to develop a smart coating for the early detection and inhibition of corrosion. The dual function of this new smart coating system is performed by pH-triggered release microcapsules. The microcapsules can be used to deliver healing agents to terminate the corrosion process at its early stage or as corrosion indicators by releasing dyes at the localized corrosion sites. The dyes can be color dyes or fluorescent dyes, with or without pH sensitivity. Microcapsules were formed through the interfacial polymerization process. The average size of the microcapsules can be adjusted from 1 to 100 micron by adjusting the emulsion formula and the microcapsule forming conditions. A typical microcapsule size is around 10 microns with a narrow size distribution. The pH sensitivity of the microcapsule can also be controlled by adjusting the emulsion formula and the polymerization reaction time. Both corrosion indicator (pH indicator) and corrosion inhibitor containing microcapsules were formed and incorporated into paint systems. Test panels of selected steels and aluminum alloys were painted using these paints. Testing of compatibility between the microcapsule system and different paint systems are in progress. Initial experiments with the microcapsule containing paint show visible color changes at induced corrosion sites and improvement of corrosion protection. Further investigation of the performance of the coating using electrochemical techniques and long term exposure are currently underway.
SU-E-T-247: Multi-Leaf Collimator Model Adjustments Improve Small Field Dosimetry in VMAT Plans
DOE Office of Scientific and Technical Information (OSTI.GOV)
Young, L; Yang, F
2014-06-01
Purpose: The Elekta beam modulator linac employs a 4-mm micro multileaf collimator (MLC) backed by a fixed jaw. Out-of-field dose discrepancies between treatment planning system (TPS) calculations and output water phantom measurements are caused by the 1-mm leaf gap required for all moving MLCs in a VMAT arc. In this study, MLC parameters are optimized to improve TPS out-of-field dose approximations. Methods: Static 2.4 cm square fields were created with a 1-mm leaf gap for MLCs that would normally park behind the jaw. Doses in the open field and leaf gap were measured with an A16 micro ion chamber andmore » EDR2 film for comparison with corresponding point doses in the Pinnacle TPS. The MLC offset table and tip radius were adjusted until TPS point doses agreed with photon measurements. Improvements to the beam models were tested using static arcs consisting of square fields ranging from 1.6 to 14.0 cm, with 45° collimator rotation, and 1-mm leaf gap to replicate VMAT conditions. Gamma values for the 3-mm distance, 3% dose difference criteria were evaluated using standard QA procedures with a cylindrical detector array. Results: The best agreement in point doses within the leaf gap and open field was achieved by offsetting the default rounded leaf end table by 0.1 cm and adjusting the leaf tip radius to 13 cm. Improvements in TPS models for 6 and 10 MV photon beams were more significant for smaller field sizes 3.6 cm or less where the initial gamma factors progressively increased as field size decreased, i.e. for a 1.6cm field size, the Gamma increased from 56.1% to 98.8%. Conclusion: The MLC optimization techniques developed will achieve greater dosimetric accuracy in small field VMAT treatment plans for fixed jaw linear accelerators. Accurate predictions of dose to organs at risk may reduce adverse effects of radiotherapy.« less
A geometrically adjustable receive array for imaging marmoset cohorts.
Gilbert, Kyle M; Gati, Joseph S; Klassen, L Martyn; Zeman, Peter; Schaeffer, David J; Everling, Stefan; Menon, Ravi S
2017-08-01
The common marmoset (Callithrix jacchus) is an increasingly popular animal model for translational neuroscience studies, during which anatomical and functional MRI can be useful investigative tools. To attain the requisite SNR for high-resolution acquisitions, the radiofrequency coil must be optimized for the marmoset; however, relatively few custom coils have been developed that maximize SNR and are compatible with accelerated acquisitions. For the study of large populations of animals, the heterogeneity in animal size reduces the effectiveness of a "one size fits all" approach to coil sizing and makes coils tailored to individual animals cost and time prohibitive. The approach taken in this study was to create an 8-channel phased-array receive coil that was adjustable to the width of the marmoset head, thereby negating the need for tailored coils while still maintaining high SNR. Two marmosets of different size were imaged on a 9.4-T small-animal scanner. Consistent SNR was achieved in the periphery of the brain between head sizes. When compared to a 15-channel, "one size fits all" receive coil, the adjustable coil achieved 57% higher SNR in the superior frontal and parietal cortices and 29% higher SNR in the centre of the brain. The mean geometry factor of the adjustable coil was less than 1.2 for a 2-fold reduction factor in the left-right and anterior-posterior directions. Geometry factors were compared to the 15-channel coil to guide future designs. The adjustable coil was shown to be a practical means for anatomical and echo-planar imaging of marmoset cohorts. Copyright © 2017 Elsevier Inc. All rights reserved.
A novel measure of effect size for mediation analysis.
Lachowicz, Mark J; Preacher, Kristopher J; Kelley, Ken
2018-06-01
Mediation analysis has become one of the most popular statistical methods in the social sciences. However, many currently available effect size measures for mediation have limitations that restrict their use to specific mediation models. In this article, we develop a measure of effect size that addresses these limitations. We show how modification of a currently existing effect size measure results in a novel effect size measure with many desirable properties. We also derive an expression for the bias of the sample estimator for the proposed effect size measure and propose an adjusted version of the estimator. We present a Monte Carlo simulation study conducted to examine the finite sampling properties of the adjusted and unadjusted estimators, which shows that the adjusted estimator is effective at recovering the true value it estimates. Finally, we demonstrate the use of the effect size measure with an empirical example. We provide freely available software so that researchers can immediately implement the methods we discuss. Our developments here extend the existing literature on effect sizes and mediation by developing a potentially useful method of communicating the magnitude of mediation. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
49 CFR 393.47 - Brake actuators, slack adjusters, linings/pads and drums/rotors.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 5 2010-10-01 2010-10-01 false Brake actuators, slack adjusters, linings/pads and..., slack adjusters, linings/pads and drums/rotors. (a) General requirements. Brake components must be... same size. (c) Slack adjusters. The effective length of the slack adjuster on each end of an axle must...
NASA Astrophysics Data System (ADS)
Wan, Gengping; Peng, Xiange; Zeng, Min; Yu, Lei; Wang, Kan; Li, Xinyue; Wang, Guizhen
2017-09-01
This paper reports the synthesis of a new type of Au@TiO2 yolk-shell nanostructures by integrating ion sputtering method with atomic layer deposition (ALD) technique and its applications as visible light-driven photocatalyst and surface-enhanced Raman spectroscopy (SERS) substrate. Both the size and amount of gold nanoparticles confined in TiO2 nanotubes could be facilely controlled via properly adjusting the sputtering time. The unique structure and morphology of the resulting Au@TiO2 samples were investigated by using various spectroscopic and microscopic techniques in detail. It is found that all tested samples can absorb visible light with a maximum absorption at localized surface plasmon resonance (LSPR) wavelengths (550-590 nm) which are determined by the size of gold nanoparticles. The Au@TiO2 yolk-shell composites were used as the photocatalyst for the degradation of methylene blue (MB). As compared with pure TiO2 nanotubes, Au@TiO2 composites exhibit improved photocatalytic properties towards the degradation of MB. The SERS effect of Au@TiO2 yolk-shell composites was also performed to investigate the detection sensitivity of MB.
Wan, Gengping; Peng, Xiange; Zeng, Min; Yu, Lei; Wang, Kan; Li, Xinyue; Wang, Guizhen
2017-09-18
This paper reports the synthesis of a new type of Au@TiO 2 yolk-shell nanostructures by integrating ion sputtering method with atomic layer deposition (ALD) technique and its applications as visible light-driven photocatalyst and surface-enhanced Raman spectroscopy (SERS) substrate. Both the size and amount of gold nanoparticles confined in TiO 2 nanotubes could be facilely controlled via properly adjusting the sputtering time. The unique structure and morphology of the resulting Au@TiO 2 samples were investigated by using various spectroscopic and microscopic techniques in detail. It is found that all tested samples can absorb visible light with a maximum absorption at localized surface plasmon resonance (LSPR) wavelengths (550-590 nm) which are determined by the size of gold nanoparticles. The Au@TiO 2 yolk-shell composites were used as the photocatalyst for the degradation of methylene blue (MB). As compared with pure TiO 2 nanotubes, Au@TiO 2 composites exhibit improved photocatalytic properties towards the degradation of MB. The SERS effect of Au@TiO 2 yolk-shell composites was also performed to investigate the detection sensitivity of MB.
NASA Astrophysics Data System (ADS)
Avitabile, Peter; O'Callahan, John
2009-01-01
Generally, response analysis of systems containing discrete nonlinear connection elements such as typical mounting connections require the physical finite element system matrices to be used in a direct integration algorithm to compute the nonlinear response analysis solution. Due to the large size of these physical matrices, forced nonlinear response analysis requires significant computational resources. Usually, the individual components of the system are analyzed and tested as separate components and their individual behavior may essentially be linear when compared to the total assembled system. However, the joining of these linear subsystems using highly nonlinear connection elements causes the entire system to become nonlinear. It would be advantageous if these linear modal subsystems could be utilized in the forced nonlinear response analysis since much effort has usually been expended in fine tuning and adjusting the analytical models to reflect the tested subsystem configuration. Several more efficient techniques have been developed to address this class of problem. Three of these techniques given as: equivalent reduced model technique (ERMT);modal modification response technique (MMRT); andcomponent element method (CEM); are presented in this paper and are compared to traditional methods.
Flow adjustment inside large finite-size wind farms approaching the infinite wind farm regime
NASA Astrophysics Data System (ADS)
Wu, Ka Ling; Porté-Agel, Fernando
2017-04-01
Due to the increasing number and the growing size of wind farms, the distance among them continues to decrease. Thus, it is necessary to understand how these large finite-size wind farms and their wakes could interfere the atmospheric boundary layer (ABL) dynamics and adjacent wind farms. Fully-developed flow inside wind farms has been extensively studied through numerical simulations of infinite wind farms. The transportation of momentum and energy is only vertical and the advection of them is neglected in these infinite wind farms. However, less attention has been paid to examine the length of wind farms required to reach such asymptotic regime and the ABL dynamics in the leading and trailing edges of the large finite-size wind farms. Large eddy simulations are performed in this study to investigate the flow adjustment inside large finite-size wind farms in conventionally-neutral boundary layer with the effect of Coriolis force and free-atmosphere stratification from 1 to 5 K/km. For the large finite-size wind farms considered in the present work, when the potential temperature lapse rate is 5 K/km, the wind farms exceed the height of the ABL by two orders of magnitude for the incoming flow inside the farms to approach the fully-developed regime. An entrance fetch of approximately 40 times of the ABL height is also required for such flow adjustment. At the fully-developed flow regime of the large finite-size wind farms, the flow characteristics match those of infinite wind farms even though they have different adjustment length scales. The role of advection at the entrance and exit regions of the large finite-size wind farms is also examined. The interaction between the internal boundary layer developed above the large finite-size wind farms and the ABL under different potential temperature lapse rates are compared. It is shown that the potential temperature lapse rate plays a role in whether the flow inside the large finite-size wind farms adjusts to the fully-developed flow regime. The flow characteristics of the wake of these large finite-size wind farms are reported to forecast the effect of large finite-size wind farms on adjacent wind farms. A power deficit as large as 8% is found at a distance of 10 km downwind from the large finite-size wind farms.
Characterization of an air jet haptic lump display.
Bianchi, Matteo; Gwilliam, James C; Degirmenci, Alperen; Okamura, Allison M
2011-01-01
During manual palpation, clinicians rely on distributed tactile information to identify and localize hard lumps embedded in soft tissue. The development of tactile feedback systems to enhance palpation using robot-assisted minimally invasive surgery (RMIS) systems is challenging due to size and weight constraints, motivating a pneumatic actuation strategy. Recently, an air jet approach has been proposed for generating a lump percept. We use this technique to direct a thin stream of air through an aperture directly on the finger pad, which indents the skin in a hemispherical manner, producing a compelling lump percept. We hypothesize that the perceived parameters of the lump (e.g. size and stiffness) can be controlled by jointly adjusting air pressure and the aperture size through which air escapes. In this work, we investigate how these control variables interact to affect perceived pressure on the finger pad. First, we used a capacitive tactile sensor array to measure the effect of aperture size on output pressure, and found that peak output pressure increases with aperture size. Second, we performed a psychophysical experiment for each aperture size to determine the just noticeable difference (JND) of air pressure on the finger pad. Subject-averaged pressure JND values ranged from 19.4-24.7 kPa, with no statistical differences observed between aperture sizes. The aperture-pressure relationship and the pressure JND values will be fundamental for future display control.
Aluja, M; Birke, A; Díaz-Fleischer, F; Rull, J
2018-05-21
Phenotypic plasticity is thought to evolve in response to environmental unpredictability and can shield genotypes from selection. However, selection can also act on plastic traits. Egg-laying behaviour, including clutch size regulation, is a plastic behavioural trait among tephritid fruit flies. We compared plasticity in clutch size regulation among females of Anastrepha ludens populations stemming from environments that differed in the degree of predictability in egg-laying opportunities. Clutch size regulation in response to hosts of different sizes was compared among flies from (a) a wild, highly isolated population, (b) a wild population that switches seasonally from a small wild host fruit that varies greatly in abundance to an abundant large-sized commercial host, and (c) a laboratory population. Flies from all three populations adjusted clutch number and size according to host size. However, flies from the heterogeneous wild environment were more plastic in adjusting clutch size than flies from agricultural settings that also laid fewer eggs; yet both populations were more plastic in adjusting clutch size in line with host size when compared with laboratory females. When wild and orchard females encountered the largest host, clutch size was extremely variable and egg regulation did not follow the same trend. Heterogeneity in host availability in space and time appears to be as important as seasonal variation in host size in maintaining plastic clutch size regulation behaviour. In stable environments, there was a clear reduction in the plasticity of these traits.
NASA Astrophysics Data System (ADS)
Zhao, Yuchen; Zemmamouche, Redouane; Vandenrijt, Jean-François; Georges, Marc P.
2018-05-01
A combination of digital holographic interferometry (DHI) and digital speckle photography (DSP) allows in-plane and out-of-plane displacement measurement between two states of an object. The former can be determined by correlating the two speckle patterns whereas the latter is given by the phase difference obtained from DHI. We show that the amplitude of numerically reconstructed object wavefront obtained from Fresnel in-line digital holography (DH), in combination with phase shifting techniques, can be used as speckle patterns in DSP. The accuracy of in-plane measurement is improved after correcting the phase errors induced by reference wave during reconstruction process. Furthermore, unlike conventional imaging system, Fresnel DH offers the possibility to resize the pixel size of speckle patterns situated on the reconstruction plane under the same optical configuration simply by zero-padding the hologram. The flexibility of speckle size adjustment in Fresnel DH ensures the accuracy of estimation result using DSP.
Programmable micrometer-sized motor array based on live cells.
Xie, Shuangxi; Wang, Xiaodong; Jiao, Niandong; Tung, Steve; Liu, Lianqing
2017-06-13
Trapping and transporting microorganisms with intrinsic motility are important tasks for biological, physical, and biomedical applications. However, fast swimming speed makes the manipulation of these organisms an inherently challenging task. In this study, we demonstrated that an optoelectrical technique, namely, optically induced dielectrophoresis (ODEP), could effectively trap and manipulate Chlamydomonas reinhardtii (C. reinhardtii) cells swimming at velocities faster than 100 μm s -1 . Furthermore, live C. reinhardtii cells trapped by ODEP can form a micrometer-sized motor array. The rotating frequency of the cells ranges from 50 to 120 rpm, which can be reversibly adjusted with a fast response speed by varying the optical intensity. Functional flagella have been demonstrated to play a decisive role in the rotation. The programmable cell array with a rotating motion can be used as a bio-micropump to drive the liquid flow in microfludic chips and may shed new light on bio-actuation.
A method for measuring particle number emissions from vehicles driving on the road.
Shi, J P; Harrison, R M; Evans, D E; Alam, A; Barnes, C; Carter, G
2002-01-01
Earlier research has demonstrated that the conditions of dilution of engine exhaust gases profoundly influence the size distribution and total number of particles emitted. Since real world dilution conditions are variable and therefore difficult to simulate, this research has sought to develop and validate a method for measuring particle number emissions from vehicles driving past on a road. This has been achieved successfully using carbon dioxide as a tracer of exhaust gas dilution. By subsequent adjustment of data to a constant dilution factor, it is possible to compare emissions from different vehicles using different technologies and fuels based upon real world emission data. Whilst further optimisation of the technique, especially in terms of matching the instrument response times is desirable, the measurements offer useful insights into emissions from gasoline and diesel vehicles, and the substantial proportion of particles emitted in the 3-7 nanometre size range.
Control of interface shape during high melting sesquioxide crystal growth by HEM technique
NASA Astrophysics Data System (ADS)
Hu, Kaiwei; Zheng, Lili; Zhang, Hui
2018-02-01
During crystal growth in heat exchanger method (HEM) system, the shape of the growth interface changes with the proceeding of the growth process, which limits the crystal size and reduces the quality of the crystal. In this paper, a modified HEM system is proposed to control the interface shape for growth of sesquioxide crystals. Numerical simulation is performed to predict heat transfer, melt flow and interface shape during growth of high melting sesquioxide crystals by the heat exchanger method. The results show that a flat or slightly convex interface shape is beneficial to reduce the solute pileup in front of the melt/crystal interface and decrease the radial temperature gradient inside the crystal during growth of sesquioxide crystals. The interface shape can be controlled by adjusting the gap size d and lower resistance heater power during growth. The growth rate and the melt/crystal interface position can be obtained by two measured temperatures.
Variable aperture-based ptychographical iterative engine method.
Sun, Aihui; Kong, Yan; Meng, Xin; He, Xiaoliang; Du, Ruijun; Jiang, Zhilong; Liu, Fei; Xue, Liang; Wang, Shouyu; Liu, Cheng
2018-02-01
A variable aperture-based ptychographical iterative engine (vaPIE) is demonstrated both numerically and experimentally to reconstruct the sample phase and amplitude rapidly. By adjusting the size of a tiny aperture under the illumination of a parallel light beam to change the illumination on the sample step by step and recording the corresponding diffraction patterns sequentially, both the sample phase and amplitude can be faithfully reconstructed with a modified ptychographical iterative engine (PIE) algorithm. Since many fewer diffraction patterns are required than in common PIE and the shape, the size, and the position of the aperture need not to be known exactly, this proposed vaPIE method remarkably reduces the data acquisition time and makes PIE less dependent on the mechanical accuracy of the translation stage; therefore, the proposed technique can be potentially applied for various scientific researches. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
[Preparation of scopolamine hydrobromide nanoparticles-in-microsphere system].
Lü, Wei-ling; Hu, Jin-hong; Zhu, Quan-gang; Li, Feng-qian
2010-07-01
This study is to prepare scopolamine hydrobromide nanoparticles-in-microsphere system (SH-NiMS) and evaluate its drug release characteristics in vitro. SH nanoparticles were prepared by ionic crosslinking method with tripolyphosphate (TPP) as crosslinker and chitosan as carrier. Orthogonal design was used to optimize the formulation of SH nanoparticles, which took the property of encapsulation efficiency and drug loading as evaluation parameters. With HPMC as carrier, adjusted the parameters of spray drying technique and sprayed the SH nanoparticles in microspheres encaposulated by HPMC was formed and which is called nanoparticles-in-microsphere system (NiMS). SH-NiMS appearances were observed by SEM, structure was obsearved by FT-IR and the release characteristics in vitro were evaluated. The optimized formulation of SH nanoparticles was TPP/CS 1:3 (w/w), HPMC 0.3%, SH 0.2%. The solution peristaltic speed of the spray drying technique was adjusted to 15%, and the temperature of inlet was 110 degrees C. The encapsulation product yeild, drug loading and particle sizes of SH-NiMS were 94.2%, 20.4%, and 1256.5 nm, respectively. The appearances and the structure of SH-NiMS were good. The preparation method of SH-NiMS is stable and reliable to use, which provide a new way to develop new dosage form.
Image processing for IMRT QA dosimetry.
Zaini, Mehran R; Forest, Gary J; Loshek, David D
2005-01-01
We have automated the determination of the placement location of the dosimetry ion chamber within intensity-modulated radiotherapy (IMRT) fields, as part of streamlining the entire IMRT quality assurance process. This paper describes the mathematical image-processing techniques to arrive at the appropriate measurement locations within the planar dose maps of the IMRT fields. A specific spot within the found region is identified based on its flatness, radiation magnitude, location, area, and the avoidance of the interleaf spaces. The techniques used include applying a Laplacian, dilation, erosion, region identification, and measurement point selection based on three parameters: the size of the erosion operator, the gradient, and the importance of the area of a region versus its magnitude. These three parameters are adjustable by the user. However, the first one requires tweaking in extremely rare occasions, the gradient requires rare adjustments, and the last parameter needs occasional fine-tuning. This algorithm has been tested in over 50 cases. In about 5% of cases, the algorithm does not find a measurement point due to the extremely steep and narrow regions within the fluence maps. In such cases, manual selection of a point is allowed by our code, which is also difficult to ascertain, since the fluence map does not yield itself to an appropriate measurement point selection.
OAJ 2.6m survey telescope: optical alignment and on-sky evaluation of IQ performances
NASA Astrophysics Data System (ADS)
Lousberg, Gregory P.; Bastin, Christian; Moreau, Vincent; Pirnay, Olivier; Flebus, Carlo; Chueca, Sergio; Iñiguez, César; Ederoclite, Alessandro; Ramió, Héctor V.; Cenarro, A. Javier
2016-08-01
AMOS has recently completed the alignment campaign of the 2.6m telescope for the Observatorio Astrofisico de Javalambre (OAJ). AMOS developed an innovative alignment technique for wide field-of-view telescopes that has been successfully implemented on the OAJ 2.6m telescope with the active support of the team of CEFCA (Centro de Estudios de Física del Cosmos de Aragón). The alignment relies on two fundamental techniques: (1) the wavefront-curvature sensing (WCS) for the evaluation of the telescope aberrations at arbitrary locations in the focal plane, and (2) the comafree point method for the adjustment of the position of the secondary mirror (M2) and of the focal plane (FP). The alignment campaign unfolds in three steps: (a) analysis of the repeatability of the WCS measurements, (b) assessment of the sensitivity of telescope wavefront error to M2 and FP position adjustments, and (c) optical alignment of the telescope. At the end of the campaign, seeing-limited performances are demonstrated in the complete focal plane. With the help of CEFCA team, the image quality of the telescope are investigated with a lucky-imaging method. Image sizes of less than 0.3 arcsec FWHM are obtained, and this excellent image quality is observed over the complete focal plane.
12 CFR 208.22 - Community development and public welfare investments.
Code of Federal Regulations, 2010 CFR
2010-01-01
... purposes of this section: (1) Low- or moderate-income area means: (i) One or more census tracts in a Metropolitan Statistical Area where the median family income adjusted for family size in each census tract is less than 80 percent of the median family income adjusted for family size of the Metropolitan...
Nanthavanij, Suebsak; Jalil, Sakib; Ammarapala, Veeris
2008-12-01
Factors which are likely to affect recommended workstation and notebook computer (NBC) adjustments to obtain ergonomic work posture during NBC operation are investigated. They are: (1) body height, (2) NBC size, and (3) workstation height (i.e., seat and work surface heights). Six recommended adjustments which are evaluated include: (1) footrest height, (2) seat support height, (3) NBC base support height, (4) distance between the user's body and NBC (or user-NBC distance), (5) tilt angle of NBC base, and (6) screen angle. It is found that body height has a significant effect on footrest height and user-NBC distance while NBC size has a significant effect on user-NBC distance, tilt angle of NBC base, and screen angle. Workstation height, on the other hand, does not show any effect on the six recommended adjustments. However, the results suggest that there are interactions between body height and NBC size, and between body height and workstation height when evaluating their effects on footrest height, tilt angle of NBC base, and screen angle.
Ultrasonically controlled particle size distribution of explosives: a safe method.
Patil, Mohan Narayan; Gore, G M; Pandit, Aniruddha B
2008-03-01
Size reduction of the high energy materials (HEM's) by conventional methods (mechanical means) is not safe as they are very sensitive to friction and impact. Modified crystallization techniques can be used for the same purpose. The solute is dissolved in the solvent and crystallized via cooling or is precipitated out using an antisolvent. The various crystallization parameters such as temperature, antisolvent addition rate and agitation are adjusted to get the required final crystal size and morphology. The solvent-antisolvent ratio, time of crystallization and yield of the product are the key factors for controlling antisolvent based precipitation process. The advantages of cavitationally induced nucleation can be coupled with the conventional crystallization process. This study includes the effect of the ultrasonically generated acoustic cavitation phenomenon on the solvent antisolvent based precipitation process. CL20, a high-energy explosive compound, is a polyazapolycyclic caged polynitramine. CL-20 has greater energy output than existing (in-use) energetic ingredients while having an acceptable level of insensitivity to shock and other external stimuli. The size control and size distribution manipulation of the high energy material (CL20) has been successfully carried out safely and quickly along with an increase in the final mass yield, compared to the conventional antisolvent based precipitation process.
Ely, Patrick C.; Young, S.P.; Isely, J.J.
2008-01-01
We estimated the population size of migrating Alabama shad Alosa alabamae below Jim Woodruff Lock and Dam in the Apalachicola River (located in the central panhandle of northwestern Florida) using mark-recapture and relative abundance techniques. After adjustment for tag loss, emigration, and mortality, the population size was estimated as 25,935 (95% confidence interval, 17,715-39,535) in 2005, 2,767 (838-5,031) in 2006, and 8,511 (5,211-14,674) in 2007. The cumulative catch rate from boat electrofishing averaged 20.47 Alabama shad per hour in 2005, 6.10 per hour in 2006, and 13.17 per hour in 2007. The relationship between population size (N) and electrofishing catch per unit effort (CPUE) was modeled by the equation N = -9008.2 + (electrofishing CPUE X 1616.4). Additionally, in 2007 the hook-and-line catch rate averaged 1.94 Alabama shad per rod hour. A predictive model relating the population size and hook-and-line CPUE of spawning American shad A. sapidissima was applied to Alabama shad hook-and-line CPUE and produced satisfactory results. Recent spawning populations of Alabama shad in the Apalachicola River are low relative to American shad populations in other southeastern U.S. rivers. ?? Copyright by the American Fisheries Society 2008.
Performance optimization of an MHD generator with physical constraints
NASA Technical Reports Server (NTRS)
Pian, C. C. P.; Seikel, G. R.; Smith, J. M.
1979-01-01
A technique has been described which optimizes the power out of a Faraday MHD generator operating under a prescribed set of electrical and magnetic constraints. The method does not rely on complicated numerical optimization techniques. Instead the magnetic field and the electrical loading are adjusted at each streamwise location such that the resultant generator design operates at the most limiting of the cited stress levels. The simplicity of the procedure makes it ideal for optimizing generator designs for system analysis studies of power plants. The resultant locally optimum channel designs are, however, not necessarily the global optimum designs. The results of generator performance calculations are presented for an approximately 2000 MWe size plant. The difference between the maximum power generator design and the optimal design which maximizes net MHD power are described. The sensitivity of the generator performance to the various operational parameters are also presented.
Dos Santos, Fernanda Karina; Nevill, Allan; Gomes, Thayse Natacha Q F; Chaves, Raquel; Daca, Timóteo; Madeira, Aspacia; Katzmarzyk, Peter T; Prista, António; Maia, José A R
2016-05-01
Children from developed and developing countries have different anthropometric characteristics which may affect their motor performance (MP). To use the allometric approach to model the relationship between body size and MP in youth from two countries differing in socio-economic status-Portugal and Mozambique. A total of 2946 subjects, 1280 Mozambicans (688 girls) and 1666 Portuguese (826 girls), aged 10-15 years were sampled. Height and weight were measured and the reciprocal ponderal index (RPI) was computed. MP included handgrip strength, 1-mile run/walk, curl-ups and standing long jump tests. A multiplicative allometric model was adopted to adjust for body size differences across countries. Differences in MP between Mozambican and Portuguese children exist, invariably favouring the latter. The allometric models used to adjust MP for differences in body size identified the optimal body shape to be either the RPI or even more linear, i.e. approximately (height/mass(0.25)). Having adjusted the MP variables for differences in body size, the differences between Mozambican and Portuguese children were invariably reduced and, in the case of grip strength, reversed. These results reinforce the notion that significant differences exist in MP across countries, even after adjusting for differences in body size.
Novel fluorescence adjustable photonic crystal materials
NASA Astrophysics Data System (ADS)
Zhu, Cheng; Liu, Xiaoxia; Ni, Yaru; Fang, Jiaojiao; Fang, Liang; Lu, Chunhua; Xu, Zhongzi
2017-11-01
Novel photonic crystal materials (PCMs) with adjustable fluorescence were fabricated by distributing organic fluorescent powders of Yb0.2Er0.4Tm0.4(TTA)3Phen into the opal structures of self-assembled silica photonic crystals (PCs). Via removing the silica solution in a constant speed, PCs with controllable thicknesses and different periodic sizes were obtained on glass slides. Yb0.2Er0.4Tm0.4(TTA)3Phen powders were subsequently distributed into the opal structures. The structures and optical properties of the prepared PCMs were investigated. Finite-difference-time-domain (FDTD) calculation was used to further analyze the electric field distributions in PCs with different periodic sizes while the relation between periodic sizes and fluorescent spectra of PCMs was discussed. The results showed that the emission color of the PCMs under irradiation of 980 nm laser can be easily adjusted from green to blue by increasing the periodic size from 250 to 450 nm.
Self-adjusted flux for the traveling solvent floating zone growth of YBaCuFeO5 crystal
NASA Astrophysics Data System (ADS)
Lai, Yen-Chung; Shu, Guo-Jiun; Chen, Wei-Tin; Du, Chao-Hung; Chou, Fang-Cheng
2015-03-01
A modified traveling solvent floating zone (TSFZ) technique was used to successfully grow a large size and high quality single crystal of multiferroic material YBaCuFeO5. This modified TSFZ growth uses a stoichiometric feed rod and pure copper oxide as the initial flux without prior knowledge of the complex phase diagram involving four elements, and the optimal flux for the growth of incongruently melt crystal is self-adjusted after a prolonged stable pulling. The wetting of the feed rod edge that often perturbs the molten zone stability was avoided by adding 2 wt% B2O3. The optimal flux concentration for the YBaCuFeO5 growth can be extracted to be near YBaCuFeO5:CuO=13:87 in molar ratio. The crystal quality was confirmed by the satisfactory refinement of crystal structure of space group P4mm and the two consecutive anisotropic antiferromagnetic phase transitions near 455 K and 170 K.
Bekkering, G E; Abou-Setta, A M; Kleijnen, J
2008-01-01
A systematic review of PDE-5 inhibitors for erectile dysfunction was performed to evaluate the utility of quantitative methods for identifying and exploring the influence of bias and study quality on pooled outcomes from meta-analyses. We included 123 randomized controlled trials (RCTs). Methodological quality was poorly reported. All three drugs appeared highly effective. Indirect adjusted analyses showed no differences between the three drugs. Funnel plots and statistical tests showed no evidence of small-study effects for sildenafil whereas there was evidence of such bias for tadalafil and vardenafil. Adjustment for missing studies using trim and fill techniques did not alter the pooled estimates substantially. The exclusion of previous sildenafil nonresponders was associated with larger treatment effects for tadalafil. This investigation was hampered by poor reporting of methodological quality, a low number of studies, heterogeneity and large effect sizes. Despite such limitations, a comprehensive assessment of biases should be a routine in systematic reviews.
NASA Astrophysics Data System (ADS)
Kennedy, J. J.; Rayner, N. A.; Smith, R. O.; Parker, D. E.; Saunby, M.
2011-07-01
Changes in instrumentation and data availability have caused time-varying biases in estimates of global and regional average sea surface temperature. The size of the biases arising from these changes are estimated and their uncertainties evaluated. The estimated biases and their associated uncertainties are largest during the period immediately following the Second World War, reflecting the rapid and incompletely documented changes in shipping and data availability at the time. Adjustments have been applied to reduce these effects in gridded data sets of sea surface temperature and the results are presented as a set of interchangeable realizations. Uncertainties of estimated trends in global and regional average sea surface temperature due to bias adjustments since the Second World War are found to be larger than uncertainties arising from the choice of analysis technique, indicating that this is an important source of uncertainty in analyses of historical sea surface temperatures. Despite this, trends over the twentieth century remain qualitatively consistent.
Temporal Trends and Factors Associated with Home Hemodialysis Technique Survival in Canada.
Perl, Jeffrey; Na, Yingbo; Tennankore, Karthik K; Chan, Christopher T
2017-07-24
The last 15 years has seen growth in home hemodialysis (HD) utilization in Canada owing to reports of improved outcomes relative to patients on conventional in-center HD. What effect growth has had on home HD technique and patient survival during this period is not known. We compared the risk of home HD technique failure, mortality, and the composite outcome among three incident cohorts of patients on home HD in Canada: 1996-2002, 2003-2007, and 2008-2012. A multivariable piece-wise exponential model was used to evaluate all outcomes using inverse probability of treatment and censoring weights. A total of 1869 incident patients on home HD were identified from the Canadian Organ Replacement Register. Relative to those treated between 2003 and 2007 ( n =568), the risk of home HD technique failure was similar between patients treated between 1996 and 2002 ( n =233; adjusted hazard ratio [AHR], 1.39; 95% confidence interval [95% CI], 0.78 to 2.46) but higher among incident patients on home HD treated between 2008 and 2012 ( n =1068; AHR, 1.51; 95% CI, 1.06 to 2.15). Relative to patients treated between 2003 and 2007, adjusted mortality was similar among those treated between 2008 and 2012 (AHR, 0.83; 95% CI, 0.58 to 1.19) and those treated between 1996 and 2002 (AHR, 0.67; 95% CI, 0.38 to 1.21). The risk of the composite outcome of death and technique failure was similar across cohorts, as was the risk of receiving a kidney transplant. Increasing age, diabetes as a comorbidity, and smoking status were associated with an increased risk of death as well as the composite outcome. Medium-sized facilities had a lower risk of death, technique failure, and the composite outcome compared with larger facilities. A higher risk of technique failure was seen in the most contemporary era. Further characterization of the risk factors for, and causes of technique failure is needed to develop strategies to improve patient retention on home HD. Copyright © 2017 by the American Society of Nephrology.
Generalizing the Network Scale-Up Method: A New Estimator for the Size of Hidden Populations*
Feehan, Dennis M.; Salganik, Matthew J.
2018-01-01
The network scale-up method enables researchers to estimate the size of hidden populations, such as drug injectors and sex workers, using sampled social network data. The basic scale-up estimator offers advantages over other size estimation techniques, but it depends on problematic modeling assumptions. We propose a new generalized scale-up estimator that can be used in settings with non-random social mixing and imperfect awareness about membership in the hidden population. Further, the new estimator can be used when data are collected via complex sample designs and from incomplete sampling frames. However, the generalized scale-up estimator also requires data from two samples: one from the frame population and one from the hidden population. In some situations these data from the hidden population can be collected by adding a small number of questions to already planned studies. For other situations, we develop interpretable adjustment factors that can be applied to the basic scale-up estimator. We conclude with practical recommendations for the design and analysis of future studies. PMID:29375167
Wang, Li-Pen; Ochoa-Rodríguez, Susana; Simões, Nuno Eduardo; Onof, Christian; Maksimović, Cedo
2013-01-01
The applicability of the operational radar and raingauge networks for urban hydrology is insufficient. Radar rainfall estimates provide a good description of the spatiotemporal variability of rainfall; however, their accuracy is in general insufficient. It is therefore necessary to adjust radar measurements using raingauge data, which provide accurate point rainfall information. Several gauge-based radar rainfall adjustment techniques have been developed and mainly applied at coarser spatial and temporal scales; however, their suitability for small-scale urban hydrology is seldom explored. In this paper a review of gauge-based adjustment techniques is first provided. After that, two techniques, respectively based upon the ideas of mean bias reduction and error variance minimisation, were selected and tested using as case study an urban catchment (∼8.65 km(2)) in North-East London. The radar rainfall estimates of four historical events (2010-2012) were adjusted using in situ raingauge estimates and the adjusted rainfall fields were applied to the hydraulic model of the study area. The results show that both techniques can effectively reduce mean bias; however, the technique based upon error variance minimisation can in general better reproduce the spatial and temporal variability of rainfall, which proved to have a significant impact on the subsequent hydraulic outputs. This suggests that error variance minimisation based methods may be more appropriate for urban-scale hydrological applications.
Chalfoun, J; Majurski, M; Peskin, A; Breen, C; Bajcsy, P; Brady, M
2015-10-01
New microscopy technologies are enabling image acquisition of terabyte-sized data sets consisting of hundreds of thousands of images. In order to retrieve and analyze the biological information in these large data sets, segmentation is needed to detect the regions containing cells or cell colonies. Our work with hundreds of large images (each 21,000×21,000 pixels) requires a segmentation method that: (1) yields high segmentation accuracy, (2) is applicable to multiple cell lines with various densities of cells and cell colonies, and several imaging modalities, (3) can process large data sets in a timely manner, (4) has a low memory footprint and (5) has a small number of user-set parameters that do not require adjustment during the segmentation of large image sets. None of the currently available segmentation methods meet all these requirements. Segmentation based on image gradient thresholding is fast and has a low memory footprint. However, existing techniques that automate the selection of the gradient image threshold do not work across image modalities, multiple cell lines, and a wide range of foreground/background densities (requirement 2) and all failed the requirement for robust parameters that do not require re-adjustment with time (requirement 5). We present a novel and empirically derived image gradient threshold selection method for separating foreground and background pixels in an image that meets all the requirements listed above. We quantify the difference between our approach and existing ones in terms of accuracy, execution speed, memory usage and number of adjustable parameters on a reference data set. This reference data set consists of 501 validation images with manually determined segmentations and image sizes ranging from 0.36 Megapixels to 850 Megapixels. It includes four different cell lines and two image modalities: phase contrast and fluorescent. Our new technique, called Empirical Gradient Threshold (EGT), is derived from this reference data set with a 10-fold cross-validation method. EGT segments cells or colonies with resulting Dice accuracy index measurements above 0.92 for all cross-validation data sets. EGT results has also been visually verified on a much larger data set that includes bright field and Differential Interference Contrast (DIC) images, 16 cell lines and 61 time-sequence data sets, for a total of 17,479 images. This method is implemented as an open-source plugin to ImageJ as well as a standalone executable that can be downloaded from the following link: https://isg.nist.gov/. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.
Kucheryavy, Pavel; He, Jibao; John, Vijay T; Maharjan, Pawan; Spinu, Leonard; Goloverda, Galina Z; Kolesnichenko, Vladimir L
2013-01-15
Magnetite nanoparticles in the size range of 3.2-7.5 nm were synthesized in high yields under variable reaction conditions using high-temperature hydrolysis of the precursor iron(II) and iron(III) alkoxides in diethylene glycol solution. The average sizes of the particles were adjusted by changing the reaction temperature and time and by using a sequential growth technique. To obtain γ-iron(III) oxide particles in the same range of sizes, magnetite particles were oxidized with dry oxygen in diethylene glycol at room temperature. The products were characterized by DLS, TEM, X-ray powder diffractometry, TGA, chemical analysis, and magnetic measurements. NMR r(1) and r(2) relaxivity measurements in water and diethylene glycol (for OH and CH(2) protons) have shown a decrease in the r(2)/r(1) ratio with the particle size reduction, which correlates with the results of magnetic measurements on magnetite nanoparticles. Saturation magnetization of the oxidized particles was found to be 20% lower than that for Fe(3)O(4) with the same particle size, but their r(1) relaxivities are similar. Because the oxidation of magnetite is spontaneous under ambient conditions, it was important to learn that the oxidation product has no disadvantages as compared to its precursor and therefore may be a better prospective imaging agent because of its chemical stability.
Yuenyongviwat, Varah; Tuntarattanapong, Pakjai; Tangtrakulwanich, Boonsin
2016-01-11
Internal fixation is one treatment for femoral neck fracture. Some devices and techniques reported improved accuracy and decreased fluoroscopic time. However, these are not widely used nowadays due to the lack of available special instruments and techniques. To improve the surgical procedure, the authors designed a new adjustable drill guide and tested the efficacy of the device. The authors developed a new adjustable drill guide for cannulated screw guide wire insertion for multiple screw fixation. Eight orthopaedic surgeons performed the experimental study to evaluate the efficacy of this device. Each surgeon performed guide wire insertion for multiple screw fixation in six synthetic femurs: three times with the new device and three times with the conventional technique. The fluoroscopic time, operative time and surgeon satisfaction were evaluated. In the operations with the new adjustable drill guide, the fluoroscopic and operative times were significantly lower than the operations with the conventional technique (p < 0.05). The mean score for the level of satisfaction of this device was also statistically significantly better (p = 0.02) than the conventional technique. The fluoroscopic and operative times with the new adjustable drill guide were reduced for multiple screw fixation of femoral neck fracture and the satisfaction of the surgeons was good.
NASA Astrophysics Data System (ADS)
Giorli, Giacomo
Deep diving odontocetes, like sperm whales, beaked whales, Risso's dolphins, and pilot whales are known to forage at deep depths in the ocean on squid and fish. These marine mammal species are top predators and for this reason are very important for the ecosystems they live in, since they can affect prey populations and control food web dynamics through top-down effects. The studies presented in this thesis investigate deep diving odontocetes. foraging strategies, and the density and size of their potential prey in the deep ocean using passive and active acoustic techniques. Ecological Acoustic Recorders (EAR) were used to monitor the foraging activity of deep diving odontocetes at three locations around the world: the Josephine Seamount High Sea Marine Protected Area (JHSMPA), the Ligurian Sea, and along the Kona coast of the island of Hawaii. In the JHSMPA, sperm whales. and beaked whales. foraging rates do not differ between night-time and day-time. However, in the Ligurian Sea, sperm whales switch to night-time foraging as the winter approaches, while beaked whales alternate between hunting mainly at night, and both at night and at day. Spatial differences were found in deep diving odontocetes. foraging activity in Hawaii where they forage most in areas with higher chlorophyll concentrations. Pilot whales (and false killer whales, clustered together in the category "blackfishes") and Risso's dolphins forage mainly at night at all locations. These two species adjust their foraging activity with the length of the night. The density and size of animals living in deep sea scattering layers was studied using a DIDSON imaging sonar at multiple stations along the Kona coast of Hawaii. The density of animals was affected by location, depth, month, and the time of day. The size of animals was influenced by station and month. The DIDSON proved to be a successful, non-invasive technique to study density and size of animals in the deep sea. Densities were found to be an order of magnitude higher than previously found with trawls, and sizes of animals were found to be 3-4 times larger than in trawl data.
Bartha, Michael C; Allie, Paul; Kokot, Douglas; Roe, Cynthia Purvis
2015-01-01
Computer users continue to report eye and upper body discomfort even as workstation flexibility has improved. Research shows a relationship between character size, viewing distance, and reading performance. Few reports exist regarding text height viewed under normal office work conditions and eye discomfort. This paper reports self-selected computer display placement, text characteristics, and subjective comfort for older and younger computer workers under real-world conditions. Computer workers were provided with monitors and adjustable display support(s). In Study 1, older workers wearing progressive-addition lenses (PALs) were observed. In study 2, older workers wearing multifocal lenses and younger workers were observed. Workers wearing PALs experienced less eye and body discomfort with adjustable displays, and less eye and neck discomfort for text visual angles near or greater than ergonomic recommendations. Older workers wearing multifocal correction positioned displays much lower than younger workers. In general, computer users did not adjust character size to ensure that fovial images of text fell within the recommended range. Ergonomic display placement recommendations should be different for computer users wearing multifocal correction for presbyopia. Ergonomic training should emphasize adjusting text size for user comfort.
Generalized adjustment by least squares ( GALS).
Elassal, A.A.
1983-01-01
The least-squares principle is universally accepted as the basis for adjustment procedures in the allied fields of geodesy, photogrammetry and surveying. A prototype software package for Generalized Adjustment by Least Squares (GALS) is described. The package is designed to perform all least-squares-related functions in a typical adjustment program. GALS is capable of supporting development of adjustment programs of any size or degree of complexity. -Author
Inertial Conference Fusion Semiannual Report October 1999 - March 2000, Volume 1, Number 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miguel, Al; Carpenter, Jason; Cassady, Cindy
2000-03-01
This first issue of the ''ICF Semiannual Report'' contains articles whose diverse subjects attest to the broad technical and scientific challenges that are at the forefront of the ICF program at LLNL. The first article describes the progress being made at solving the surface roughness problem on capsule mandrels. All NIF capsule options, except machined beryllium, require a mandrel upon which the ablator is deposited. This mandrel sets the baseline sphericity of the final capsule. Problems involving defects in the mandrel have been overcome using various techniques so that 2-mm-size mandrels can now be made that meet the NIF designmore » specification. The second article validates and provides a detailed numerical investigation of the shadowgraph technique currently used to diagnose the surface roughness of a fuel ice layer inside of a transparent capsule. It is crucial for the success of the indirect-drive ignition targets that the techniques used to characterize ice-surface roughness be well understood. This study identifies methods for analyzing the bright band that give an accurate measure of the ice-surface roughness. The third article describes a series of realistic laser and target modifications that can lead to 3-4 times more energy coupling and 10 times greater yield from a NIF indirect-drive ignition target. Target modifications include using various mixtures of rare-earth and other high-Z metals as hohlraum wall material and adjusting the laser-entrance-hole size and the case-to-capsule size ratio. Each option is numerically examined separately and together. The fourth article reviews how detailed x-ray and Thomson scattering measurements from a high-density and high-temperature gasbag plasma are used to test spectroscopic modeling techniques. There is good agreement between the model and experimental dielectronic capture satellite intensities. However, improvements are required in the modeling of inner shell collisionally populated satellite states. These improvements can have important implications for the interpretation of inertial confinement fusion capsule implosions. The fifth article reports on experiments using the OMEGA laser that investigate symmetry control in hohlraums. The experiments explore a control method where different pointings are used for different groups of beams and the beams are staggered in time. This gives a dynamic beam pointing adjustment during the laser pulse. Measurements of the capsule symmetry show agreement with simulations and show the ability to control low-mode drive asymmetries. The sixth article reports on the observation of an intense high-energy proton beam produced by irradiating a thin-foil target with the petawatt laser. This experiment is important for understanding new mechanisms of ion acceleration using high-intensity short-pulse lasers. Proton beams of the type observed here could be of interest for applications ranging from medicine to fast ignition.« less
Sample size determination for equivalence assessment with multiple endpoints.
Sun, Anna; Dong, Xiaoyu; Tsong, Yi
2014-01-01
Equivalence assessment between a reference and test treatment is often conducted by two one-sided tests (TOST). The corresponding power function and sample size determination can be derived from a joint distribution of the sample mean and sample variance. When an equivalence trial is designed with multiple endpoints, it often involves several sets of two one-sided tests. A naive approach for sample size determination in this case would select the largest sample size required for each endpoint. However, such a method ignores the correlation among endpoints. With the objective to reject all endpoints and when the endpoints are uncorrelated, the power function is the production of all power functions for individual endpoints. With correlated endpoints, the sample size and power should be adjusted for such a correlation. In this article, we propose the exact power function for the equivalence test with multiple endpoints adjusted for correlation under both crossover and parallel designs. We further discuss the differences in sample size for the naive method without and with correlation adjusted methods and illustrate with an in vivo bioequivalence crossover study with area under the curve (AUC) and maximum concentration (Cmax) as the two endpoints.
Ilioi, Elena Cristiana; Golombok, Susan
2015-01-01
BACKGROUND Adolescence is a transitional time for identity formation and relationships with parents. While people born through assisted reproduction techniques (ART) appear to be well adjusted in childhood, it is unclear whether these findings carry into adolescence, and whether diverse ART have different psychological outcomes. This review summarizes what is known about the psychological adjustment and family relationships of the growing number of children born through ART who are reaching adolescence. METHODS The Pubmed, Web of Knowledge, PsycINFO and Scopus databases were searched systematically for peer reviewed papers focusing on adolescent psychological adjustment and parent–adolescent relationships in families created by ART. Key search inclusion criteria included all papers published in English relating to adolescents aged between 11 and 18 years. RESULTS Seventeen publications with varied methodologies were identified by this review. Only papers relating to in vitro fertilization (IVF), egg donation and donor insemination were identified. Results were categorized according to ART that used the parents' own gametes (IVF) and those that involved reproductive donation (egg donation, and donor insemination). Compared with naturally conceived adolescents and standardized normative samples, adolescents born through all ARTs seemed to be equally well adjusted, and to have positive parent–adolescent relationships. Some differences were however identified based on the type of ART used. In particular, the sex of the parent and child, along with age and process of disclosure of the adolescent's conception were identified as key mediators of parent–adolescent relationships in families created by donor insemination. CONCLUSIONS The studies in this review indicate that children born through ART have positive parent–adolescent relationships and are well adjusted, with some slight differences based on different ART. The generalizability of findings may be limited by the general low level of disclosure to adolescents in some of the publications, the small sample sizes of studies in the field, along with the large age range that encompasses adolescence. Findings should also be interpreted in light of the fact that many publications focus on singleton births. Future studies should also focus on egg donation, surrogacy and embryo donation, as well as the disclosure processes, and adolescents born into non-traditional families (same-sex or single parents) or those born using different types of donor (anonymous, identity-release or known). PMID:25281685
Smith, H K; Montpetit, R R; Perrault, H
1988-01-01
Few studies have examined the aerobic demand of backstroke swimming, and its relation to body morphology, technique, or performance. The aims of this study were thus to: i) describe the aerobic demand of backstroke swimming in proficient swimmers at high velocities; ii) assess the effects of body size and stroke technique on submaximal and maximal O2 costs, and; iii) test for a relationship between submaximal O2 costs and maximal performance. Sixteen male competitive swimmers were tested during backstroke swimming at velocities from 1.0 to 1.4 m.s-1. Results showed that VO2 increased linearly with velocity (m.s-1) following the equation VO2 = 6.28v - 3.81 (r = 0.77, SEE/Y = 14.9%). VO2 was also related to the subjects' body mass, height, and armspan. Longer distances per stroke were associated with lower O2 costs, and better maximal performances. A significant relation was found between VO2 at 1.1 m.s-1, adjusted for body mass, and 400 m performance (r = -0.78). Submaximal VO2 was also related to reported times for 100 m and 200 m races. Multiple correlation analyses indicated that VO2 at 1.1 m.s-1 and VO2max accounted for up to 78% of the variance in maximal performances. These results suggest that the assessment of submaximal and maximal VO2 during backstroke swimming may be of value in the training and testing programs of competitive swimmers.
Adaptive x-ray optics development at AOA-Xinetics
NASA Astrophysics Data System (ADS)
Lillie, Charles F.; Cavaco, Jeff L.; Brooks, Audrey D.; Ezzo, Kevin; Pearson, David D.; Wellman, John A.
2013-05-01
Grazing-incidence optics for X-ray applications require extremely smooth surfaces with precise mirror figures to provide well focused beams and small image spot sizes for astronomical telescopes and laboratory test facilities. The required precision has traditionally been achieved by time-consuming grinding and polishing of thick substrates with frequent pauses for precise metrology to check the mirror figure. More recently, substrates with high quality surface finish and figures have become available at reasonable cost, and techniques have been developed to mechanically adjust the figure of these traditionally polished substrates for ground-based applications. The beam-bending techniques currently in use are mechanically complex, however, with little control over mid-spatial frequency errors. AOA-Xinetics has been developing been developing techniques for shaping grazing incidence optics with surface-normal and surface-parallel electrostrictive Lead magnesium niobate (PMN) actuators bonded to mirror substrates for several years. These actuators are highly reliable; exhibit little to no hysteresis, aging or creep; and can be closely spaced to correct low and mid-spatial frequency errors in a compact package. In this paper we discuss recent development of adaptive x-ray optics at AOA-Xinetics.
Adaptive x-ray optics development at AOA-Xinetics
NASA Astrophysics Data System (ADS)
Lillie, Charles F.; Pearson, David D.; Cavaco, Jeffrey L.; Plinta, Audrey D.; Wellman, John A.
2012-10-01
Grazing-incidence optics for X-ray applications require extremely smooth surfaces with precise mirror figures to provide well focused beams and small image spot sizes for astronomical telescopes and laboratory test facilities. The required precision has traditionally been achieved by time-consuming grinding and polishing of thick substrates with frequent pauses for precise metrology to check the mirror figure. More recently, substrates with high quality surface finish and figures have become available at reasonable cost, and techniques have been developed to mechanically adjust the figure of these traditionally polished substrates for ground-based applications. The beam-bending techniques currently in use are mechanically complex, however, with little control over mid-spatial frequency errors. AOA-Xinetics has been developing been developing techniques for shaping grazing incidence optics with surface-normal and surface-parallel electrostrictive Lead magnesium niobate (PMN) actuators bonded to mirror substrates for several years. These actuators are highly reliable; exhibit little to no hysteresis, aging or creep; and can be closely spaced to correct low and mid-spatial frequency errors in a compact package. In this paper we discuss recent development of adaptive x-ray optics at AOAXinetics.
Jung, R.E.; Droege, S.; Sauer, J.R.; Landy, R.B.
2000-01-01
In response to concerns about amphibian declines, a study evaluating and validating amphibian monitoring techniques was initiated in Shenandoah and Big Bend National Parks in the spring of 1998. We evaluate precision, bias, and efficiency of several sampling methods for terrestrial and streamside salamanders in Shenandoah National Park and assess salamander abundance in relation to environmental variables, notably soil and water pH. Terrestrial salamanders, primarily redback salamanders (Plethodon cinereus), were sampled by searching under cover objects during the day in square plots (10 to 35 m2). We compared population indices (mean daily and total counts) with adjusted population estimates from capture-recapture. Analyses suggested that the proportion of salamanders detected (p) during sampling varied among plots, necessitating the use of adjusted population estimates. However, adjusted population estimates were less precise than population indices, and may not be efficient in relating salamander populations to environmental variables. In future sampling, strategic use of capture-recapture to verify consistency of p's among sites may be a reasonable compromise between the possibility of bias in estimation of population size and deficiencies due to inefficiency associated with the estimation of p. The streamside two-lined salamander (Eurycea bislineata) was surveyed using four methods: leaf litter refugia bags, 1 m2 quadrats, 50 x 1 m visual encounter transects, and electric shocking. Comparison of survey methods at nine streams revealed congruent patterns of abundance among sites, suggesting that relative bias among the methods is similar, and that choice of survey method should be based on precision and logistical efficiency. Redback and two-lined salamander abundance were not significantly related to soil or water pH, respectively.
Saied, N N; Helwani, M A; Weavind, L M; Shi, Y; Shotwell, M S; Pandharipande, P P
2017-01-01
The anaesthetic technique may influence clinical outcomes, but inherent confounding and small effect sizes makes this challenging to study. We hypothesized that regional anaesthesia (RA) is associated with higher survival and fewer postoperative organ dysfunctions when compared with general anaesthesia (GA). We matched surgical procedures and type of anaesthesia using the US National Surgical Quality Improvement database, in which 264,421 received GA and 64,119 received RA. Procedures were matched according to Current Procedural Terminology (CPT) and ASA physical status classification. Our primary outcome was 30-day postoperative mortality and secondary outcomes were hospital length of stay, and postoperative organ system dysfunction. After matching, multiple regression analysis was used to examine associations between anaesthetic type and outcomes, adjusting for covariates. After matching and adjusting for covariates, type of anaesthesia did not significantly impact 30-day mortality. RA was significantly associated with increased likelihood of early discharge (HR 1.09; P< 0.001), 47% lower odds of intraoperative complications, and 24% lower odds of respiratory complications. RA was also associated with 16% lower odds of developing deep vein thrombosis and 15% lower odds of developing any one postoperative complication (OR 0.85; P < 0.001). There was no evidence of an effect of anaesthesia technique on postoperative MI, stroke, renal complications, pulmonary embolism or peripheral nerve injury. After adjusting for clinical and patient characteristic confounders, RA was associated with significantly lower odds of several postoperative complications, decreased hospital length of stay, but not mortality when compared with GA. © The Author 2016. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Development of an expanded-field irradiation technique using a gimbaled x-ray head
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ono, Tomohiro; Miyabe, Yuki, E-mail: miyabe@kuhp.kyoto-u.ac.jp; Yamada, Masahiro
2014-10-15
Purpose: The Vero4DRT has a maximum field size of 150.0 × 150.0 mm. The purpose of the present study was to develop expanded-field irradiation techniques using the unique gimbaled x-ray head of the Vero4DRT and to evaluate the dosimetric characteristics thereof. Methods: Two techniques were developed. One features gimbal swing irradiation and multiple static segments consisting of four separate fields exhibiting 2.39° gimbal rotation around two orthogonal axes. The central beam axis for each piecewise-field is shifted 40 mm from the isocenters of the left–right (LR) and superior–inferior (SI) directions, and, thus, the irradiation field size is expanded to 230.8 × 230.8 mm. Adjacentmore » regions were created at the isocenter (a center-adjacent expandedfield) and 20 mm from the isocenter (an off-adjacent expandedfield). The field gaps or overlaps of combined piecewise-fields were established by adjustment of gimbal rotation and movement of the multileaf collimator (MLC). Another technique features dynamic segment irradiation in which the beam is delivered while rotating the gimbal. The dose profile is controlled by a combination of gimbal swing motion and opening and closing of the MLC. This enabled the authors to expand the irradiation field on the LR axis because the direction of MLC motion is parallel to that axis. A field 220.6 × 150.0 mm in dimensions was configured and examined. To evaluate the dosimetric characteristics of the expandedfields, films inserted into water-equivalent phantoms at depths of 50, 100, and 150 mm were irradiated and field sizes, penumbrae, flatness, and symmetry analyzed. In addition, the expanded-field irradiation techniques were applied to intensity-modulated radiation therapy (IMRT). A head-and-neck IMRT field, created using a conventional Linac (the Varian Clinac iX), was reproduced employing an expanded-field of the Vero4DRT. The simulated dose distribution for the expanded-IMRT field was compared to the measured dose distribution. Results: The field sizes, penumbrae, flatness, and symmetry of the center- and off-adjacent expanded-fields were 230.2–232.1 mm, 6.8–10.7 mm, 2.3%–5.1%, and −0.5% to −0.4%, respectively, at a depth of 100 mm. Similarly, the field sizes, penumbrae, flatness, and symmetry of dynamic segment irradiation on the LR axis were 219.2 mm, 6.0–6.2 mm, 3.4%, and −0.1%, respectively, at a depth of 100 mm. In the area of expanded-IMRT dose distribution, the passing rate of 5% dose difference was 85.8% between measurements and simulation, and the 3%/3 mm gamma passing rate was 96.4%. Conclusions: Expanded-field irradiation techniques were developed using a gimbaled x-ray head. The techniques effectively extend target areas, as required when whole-breast irradiation or head-and-neck IMRT is contemplated.« less
On plant detection of intact tomato fruits using image analysis and machine learning methods.
Yamamoto, Kyosuke; Guo, Wei; Yoshioka, Yosuke; Ninomiya, Seishi
2014-07-09
Fully automated yield estimation of intact fruits prior to harvesting provides various benefits to farmers. Until now, several studies have been conducted to estimate fruit yield using image-processing technologies. However, most of these techniques require thresholds for features such as color, shape and size. In addition, their performance strongly depends on the thresholds used, although optimal thresholds tend to vary with images. Furthermore, most of these techniques have attempted to detect only mature and immature fruits, although the number of young fruits is more important for the prediction of long-term fluctuations in yield. In this study, we aimed to develop a method to accurately detect individual intact tomato fruits including mature, immature and young fruits on a plant using a conventional RGB digital camera in conjunction with machine learning approaches. The developed method did not require an adjustment of threshold values for fruit detection from each image because image segmentation was conducted based on classification models generated in accordance with the color, shape, texture and size of the images. The results of fruit detection in the test images showed that the developed method achieved a recall of 0.80, while the precision was 0.88. The recall values of mature, immature and young fruits were 1.00, 0.80 and 0.78, respectively.
Poirier, Frédéric J A M; Faubert, Jocelyn
2012-06-22
Facial expressions are important for human communications. Face perception studies often measure the impact of major degradation (e.g., noise, inversion, short presentations, masking, alterations) on natural expression recognition performance. Here, we introduce a novel face perception technique using rich and undegraded stimuli. Participants modified faces to create optimal representations of given expressions. Using sliders, participants adjusted 53 face components (including 37 dynamic) including head, eye, eyebrows, mouth, and nose shape and position. Data was collected from six participants and 10 conditions (six emotions + pain + gender + neutral). Some expressions had unique features (e.g., frown for anger, upward-curved mouth for happiness), whereas others had shared features (e.g., open eyes and mouth for surprise and fear). Happiness was different from other emotions. Surprise was different from other emotions except fear. Weighted sum morphing provides acceptable stimuli for gender-neutral and dynamic stimuli. Many features were correlated, including (1) head size with internal feature sizes as related to gender, (2) internal feature scaling, and (3) eyebrow height and eye openness as related to surprise and fear. These findings demonstrate the method's validity for measuring the optimal facial expressions, which we argue is a more direct measure of their internal representations.
Avdievich, Nikolai I.; Pan, Jullie W.; Hetherington, Hoby P.
2013-01-01
Transceiver surface coil arrays improve transmit performance (B1/√kW) and B1 homogeneity for head imaging up to 9.4 T. To further improve reception performance and parallel imaging the number of array elements has to be increased with correspondent decrease of their size. With a large number of small interacting antennas decoupling is one of the most challenging aspects in the design and construction of transceiver arrays. Previously described decoupling techniques using geometric overlap, inductive or capacitive decoupling have focused on eliminating only the reactance of the mutual impedance, which can limit the obtainable decoupling to −10 dB due to residual mutual resistance. A novel resonant inductive decoupling (RID) method, which allows compensation for both reactive and resistive components of the mutual impedance between the adjacent surface coils, has been developed and experimentally verified. This method provides an easy way to adjust the decoupling remotely by changing the resonance frequency of the RID circuit through adjustment of a variable capacitor. As an example a single row (1×16) 7T transceiver head array of n=16 small overlapped surface coils using RID decoupling between adjacent coils was built. In combination with overlapped coils the RID technique achieved better than −24 dB of decoupling for all adjacent coils. PMID:23775840
Caetano, Raul; Mills, Britain A; Harris, T Robert
2012-01-01
This study was conducted to examine discrepancies in alcohol consumption estimates between a self-reported standard quantity-frequency measure and an adjusted version based on respondents' typically used container size. Using a multistage cluster sample design, 5,224 Hispanic individuals 18 years of age and older were selected from the household population in five metropolitan areas of the United States: Miami, New York, Philadelphia, Houston, and Los Angeles. The survey-weighted response rate was 76%. Personal interviews lasting an average of 1 hour were conducted in respondents' homes in either English or Spanish. The overall effect of container adjustment was to increase estimates of ethanol consumption by 68% for women (range across Hispanic groups: 17%-99%) and 30% for men (range: 14%-42%). With the exception of female Cuban American, Mexican American, and South/Central American beer drinkers and male Cuban American wine drinkers, all percentage differences between unadjusted and container-adjusted estimates were positive. Second, container adjustments produced the largest change for volume of distilled spirits, followed by wine and beer. Container size adjustments generally produced larger percentage increases in consumption estimates for the higher volume drinkers, especially the upper tertile of female drinkers. Self-reported alcohol consumption based on standard drinks underreports consumption when compared with reports based on the amount of alcohol poured into commonly used containers.
Can SNOMED CT be squeezed without losing its shape?
López-García, Pablo; Schulz, Stefan
2016-09-21
In biomedical applications where the size and complexity of SNOMED CT become problematic, using a smaller subset that can act as a reasonable substitute is usually preferred. In a special class of use cases-like ontology-based quality assurance, or when performing scaling experiments for real-time performance-it is essential that modules show a similar shape than SNOMED CT in terms of concept distribution per sub-hierarchy. Exactly how to extract such balanced modules remains unclear, as most previous work on ontology modularization has focused on other problems. In this study, we investigate to what extent extracting balanced modules that preserve the original shape of SNOMED CT is possible, by presenting and evaluating an iterative algorithm. We used a graph-traversal modularization approach based on an input signature. To conform to our definition of a balanced module, we implemented an iterative algorithm that carefully bootstraped and dynamically adjusted the signature at each step. We measured the error for each sub-hierarchy and defined convergence as a residual sum of squares <1. Using 2000 concepts as an initial signature, our algorithm converged after seven iterations and extracted a module 4.7 % the size of SNOMED CT. Seven sub-hierarhies were either over or under-represented within a range of 1-8 %. Our study shows that balanced modules from large terminologies can be extracted using ontology graph-traversal modularization techniques under certain conditions: that the process is repeated a number of times, the input signature is dynamically adjusted in each iteration, and a moderate under/over-representation of some hierarchies is tolerated. In the case of SNOMED CT, our results conclusively show that it can be squeezed to less than 5 % of its size without any sub-hierarchy losing its shape more than 8 %, which is likely sufficient in most use cases.
Novikov, Alexey; Caroff, Martine; Della-Negra, Serge; Depauw, Joël; Fallavier, Mireille; Le Beyec, Yvon; Pautrat, Michèle; Schultz, J Albert; Tempez, Agnès; Woods, Amina S
2005-01-01
A Au-Si liquid metal ion source which produces Au(n) clusters over a large range of sizes was used to study the dependence of both the molecular ion desorption yield and the damage cross-section on the size (n = 1 to 400) and on the kinetic energy (E = 10 to 500 keV) of the clusters used to bombard bioorganic surfaces. Three pure peptides with molecular masses between 750 and 1200 Da were used without matrix. [M+H](+) and [M+cation](+) ion emission yields were enhanced by as much as three orders of magnitude when bombarding with Au(400) (4+) instead of monatomic Au(+), yet very little damage was induced in the samples. A 100-fold increase in the molecular ion yield was observed when the incident energy of Au(9) (+) was varied from 10 to 180 keV. Values of emission yields and damage cross-sections are presented as a function of cluster size and energy. The possibility to adjust both cluster size and energy, depending on the application, makes the analysis of biomolecules by secondary ion mass spectrometry an extremely powerful and flexible technique, particularly when combined with orthogonal time-of-flight mass spectrometry that then allows fast measurements using small primary ion beam currents. Copyright (c) 2005 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Anand, Madhu
Nanoparticles have received significant attention because of their unusual characteristics including high surface area to volume ratios. Materials built from nanoparticles possess unique chemical, physical, mechanical and optical properties. Due to these properties, they hold potential in application areas such as catalysts, sensors, semiconductors and optics. At the same time, CO 2 in the form of supercritical fluid or CO2 gas-expanded liquid mixtures has gained significant attention in the area of processing nanostructures. This dissertation focuses on the synthesis and processing of nanoparticles using CO2 tunable solvent systems. Nanoparticle properties depend heavily on their size and, as such, the ability to finely control the size and uniformity of nanoparticles is of utmost importance. Solution based nanoparticle formation techniques are attractive due to their simplicity, but they often result in the synthesis of particles with a wide size range. To address this limitation, a post-synthesis technique has been developed in this dissertation to fractionate polydisperse nanoparticles ( s . = 30%) into monodisperse fractions ( s . = 8%) using tunable physicochemical properties of CO 2 expanded liquids, where CO2 is employed as an antisolvent. This work demonstrates that by controlling the addition of CO2 (pressurization) to an organic dispersion of nanoparticles, the ligand stabilized nanoparticles can be size selectively precipitated within a novel high pressure apparatus that confines the particle precipitation to a specified location on a surface. Unlike current techniques, this CO2 expanded liquid approach provides faster and more efficient particle size separation, reduction in organic solvent usage, and pressure tunable size selection in a single process. To improve our fundamental understanding and to further refine the size separation process, a detailed study has been performed to identify the key parameters enabling size separation of various nanoparticle populations. This study details the influence of various factors on the size separation process, such as the types of nanoparticles, ligand type and solvent type as well as the use of recursive fractionation and the time allowed for settling during each fractionation step. This size selective precipitation technique was also applied to fractionate and separate polydisperse dispersions of CdSe/ZnS semiconductor nanocrystals into very distinct size and color fractions based solely on the pressure tunable solvent properties of CO2 expanded liquids. This size selective precipitation of nanoparticles is achieved by finely tuning the solvent strength of the CO2/organic solvent medium by simply adjusting the applied CO2 pressure. These subtle changes affect the balance between osmotic repulsive and van der Waals attractive forces thereby allowing fractionation of the nanocrystals into multiple narrow size populations. Thermodynamic analysis of nanoparticle size selective fractionation was performed to develop a theoretical model based on the thermodynamic properties of gas expanded liquids. We have used the general phenomenon of nanoparticle precipitation with CO2 expanded liquids to create dodecanethiol stabilized gold nanoparticle thin films. This method utilizes CO2 as an anti-solvent for low defect, wide area gold nanoparticle film formation employing monodisperse gold nanoparticles. Dodecanethiol stabilized gold particles are precipitated from hexane by controllably expanding the solution with carbon dioxide. Subsequent addition of carbon dioxide as a dense supercritical fluid then provides for removal of the organic solvent while avoiding the dewetting effects common to evaporating solvents. Unfortunately, the use of carbon dioxide as a neat solvent in nanoparticles synthesis and processing is limited by the very poor solvent strength of dense phase CO2. As a result, most current techniques employed to synthesize and disperse nanoparticles in neat carbon dioxide require the use of environmentally persistent fluorinated compounds as metal precursors and/or stabilizing ligands. This dissertation presents the first report of the simultaneous synthesis and stabilization of metallic nanoparticles in carbon dioxide solvent without the use of any fluorinated compounds thereby further enabling the use of CO 2 as a green solvent medium in nanomaterials synthesis and processing.
A front-end wafer-level microsystem packaging technique with micro-cap array
NASA Astrophysics Data System (ADS)
Chiang, Yuh-Min
2002-09-01
The back-end packaging process is the remaining challenge for the micromachining industry to commercialize microsystem technology (MST) devices at low cost. This dissertation presents a novel wafer level protection technique as a final step of the front-end fabrication process for MSTs. It facilitates improved manufacturing throughput and automation in package assembly, wafer level testing of devices, and enhanced device performance. The method involves the use of a wafer-sized micro-cap array, which consists of an assortment of small caps micro-molded onto a material with adjustable shapes and sizes to serve as protective structures against the hostile environments during packaging. The micro-cap array is first constructed by a micromachining process with micro-molding technique, then sealed to the device wafer at wafer level. Epoxy-based wafer-level micro cap array has been successfully fabricated and showed good compatibility with conventional back-end packaging processes. An adhesive transfer technique was demonstrated to seal the micro cap array with a MEMS device wafer. No damage or gross leak was observed while wafer dicing or later during a gross leak test. Applications of the micro cap array are demonstrated on MEMS, microactuators fabricated using CRONOS MUMPS process. Depending on the application needs, the micro-molded cap can be designed and modified to facilitate additional component functions, such as optical, electrical, mechanical, and chemical functions, which are not easily achieved in the device by traditional means. Successful fabrication of a micro cap array comprised with microlenses can provide active functions as well as passive protection. An optical tweezer array could be one possibility for applications of a micro cap with microlenses. The micro cap itself could serve as micro well for DNA or bacteria amplification as well.
Comparison of Acceleration Techniques for Selected Low-Level Bioinformatics Operations
Langenkämper, Daniel; Jakobi, Tobias; Feld, Dustin; Jelonek, Lukas; Goesmann, Alexander; Nattkemper, Tim W.
2016-01-01
Within the recent years clock rates of modern processors stagnated while the demand for computing power continued to grow. This applied particularly for the fields of life sciences and bioinformatics, where new technologies keep on creating rapidly growing piles of raw data with increasing speed. The number of cores per processor increased in an attempt to compensate for slight increments of clock rates. This technological shift demands changes in software development, especially in the field of high performance computing where parallelization techniques are gaining in importance due to the pressing issue of large sized datasets generated by e.g., modern genomics. This paper presents an overview of state-of-the-art manual and automatic acceleration techniques and lists some applications employing these in different areas of sequence informatics. Furthermore, we provide examples for automatic acceleration of two use cases to show typical problems and gains of transforming a serial application to a parallel one. The paper should aid the reader in deciding for a certain techniques for the problem at hand. We compare four different state-of-the-art automatic acceleration approaches (OpenMP, PluTo-SICA, PPCG, and OpenACC). Their performance as well as their applicability for selected use cases is discussed. While optimizations targeting the CPU worked better in the complex k-mer use case, optimizers for Graphics Processing Units (GPUs) performed better in the matrix multiplication example. But performance is only superior at a certain problem size due to data migration overhead. We show that automatic code parallelization is feasible with current compiler software and yields significant increases in execution speed. Automatic optimizers for CPU are mature and usually no additional manual adjustment is required. In contrast, some automatic parallelizers targeting GPUs still lack maturity and are limited to simple statements and structures. PMID:26904094
Comparison of Acceleration Techniques for Selected Low-Level Bioinformatics Operations.
Langenkämper, Daniel; Jakobi, Tobias; Feld, Dustin; Jelonek, Lukas; Goesmann, Alexander; Nattkemper, Tim W
2016-01-01
Within the recent years clock rates of modern processors stagnated while the demand for computing power continued to grow. This applied particularly for the fields of life sciences and bioinformatics, where new technologies keep on creating rapidly growing piles of raw data with increasing speed. The number of cores per processor increased in an attempt to compensate for slight increments of clock rates. This technological shift demands changes in software development, especially in the field of high performance computing where parallelization techniques are gaining in importance due to the pressing issue of large sized datasets generated by e.g., modern genomics. This paper presents an overview of state-of-the-art manual and automatic acceleration techniques and lists some applications employing these in different areas of sequence informatics. Furthermore, we provide examples for automatic acceleration of two use cases to show typical problems and gains of transforming a serial application to a parallel one. The paper should aid the reader in deciding for a certain techniques for the problem at hand. We compare four different state-of-the-art automatic acceleration approaches (OpenMP, PluTo-SICA, PPCG, and OpenACC). Their performance as well as their applicability for selected use cases is discussed. While optimizations targeting the CPU worked better in the complex k-mer use case, optimizers for Graphics Processing Units (GPUs) performed better in the matrix multiplication example. But performance is only superior at a certain problem size due to data migration overhead. We show that automatic code parallelization is feasible with current compiler software and yields significant increases in execution speed. Automatic optimizers for CPU are mature and usually no additional manual adjustment is required. In contrast, some automatic parallelizers targeting GPUs still lack maturity and are limited to simple statements and structures.
Compact and tunable focusing device for plasma wakefield acceleration
NASA Astrophysics Data System (ADS)
Pompili, R.; Anania, M. P.; Chiadroni, E.; Cianchi, A.; Ferrario, M.; Lollo, V.; Notargiacomo, A.; Picardi, L.; Ronsivalle, C.; Rosenzweig, J. B.; Shpakov, V.; Vannozzi, A.
2018-03-01
Plasma wakefield acceleration, either driven by ultra-short laser pulses or electron bunches, represents one of the most promising techniques able to overcome the limits of conventional RF technology and allows the development of compact accelerators. In the particle beam-driven scenario, ultra-short bunches with tiny spot sizes are required to enhance the accelerating gradient and preserve the emittance and energy spread of the accelerated bunch. To achieve such tight transverse beam sizes, a focusing system with short focal length is mandatory. Here we discuss the development of a compact and tunable system consisting of three small-bore permanent-magnet quadrupoles with 520 T/m field gradient. The device has been designed in view of the plasma acceleration experiments planned at the SPARC_LAB test-facility. Being the field gradient fixed, the focusing is adjusted by tuning the relative position of the three magnets with nanometer resolution. Details about its magnetic design, beam-dynamics simulations, and preliminary results are examined in the paper.
Self-arraying of charged levitating droplets.
Kauffmann, Paul; Nussbaumer, Jérémie; Masse, Alain; Jeandey, Christian; Grateau, Henri; Pham, Pascale; Reyne, Gilbert; Haguet, Vincent
2011-06-01
Diamagnetic levitation of water droplets in air is a promising phenomenon to achieve contactless manipulation of chemical or biochemical samples. This noncontact handling technique prevents contaminations of samples as well as provides measurements of interaction forces between levitating reactors. Under a nonuniform magnetic field, diamagnetic bodies such as water droplets experience a repulsive force which may lead to diamagnetic levitation of a single or few micro-objects. The levitation of several repulsively charged picoliter droplets was successfully performed in a ~1 mm(2) adjustable flat magnetic well provided by a centimeter-sized cylindrical permanent magnet structure. Each droplet position results from the balance between the centripetal diamagnetic force and the repulsive Coulombian forces. Levitating water droplets self-organize into satellite patterns or thin clouds, according to their charge and size. Small triangular lattices of identical droplets reproduce magneto-Wigner crystals. Repulsive forces and inner charges can be measured in the piconewton and the femtocoulomb ranges, respectively. Evolution of interaction forces is accurately followed up over time during droplet evaporation.
Flohil, S C; van Dorst, A M J M; Nijsten, T; Martino Neumann, H A; Munte, K
2013-10-01
In the Netherlands basal cell carcinomas (BCC) are eligible for Mohs microscopic surgery (MMS) if certain criteria are fulfilled. To study the MMS indication criteria practised at the department of dermatology of the Erasmus University Medical Center, Rotterdam and to identify predictive factors for extensive subclinical tumour spread among BCCs eligible for MMS. Pre-operative patient and tumour characteristics were derived retrospectively between January 2nd 2006 and December 28th 2009 from 1174 patient records, accounting for 1464 BCCs. Multivariate logistic regression models were used to calculate crude and adjusted odds ratios (OR) with 95% confidence intervals (CI) for one vs. two or more stages and for narrow (≤ 2 stages) vs. extensive subclinical spread (≥ 3 stages). H-zone location [adjusted OR 1.51 (95% CI 1.16-1.96)], recurrent tumour [adjusted OR 1.50 (95% CI 1.11-2.02)], aggressive subtype [adjusted OR 1.25 (95% CI 1.01-1.56)] and tumour size ≥ 11 mm [adjusted OR 1.53 (95% CI 1.20-1.96)] were significantly associated with two or more stages. Predictive factors for extensive subclinical spread were recurrent tumour [adjusted OR 2.26 (95% CI 1.61-3.17)], tumour size ≥ 21 mm [adjusted OR 1.69 (95% CI 1.13-2.51)] and location in the H-zone [adjusted OR 1.68 (95% CI 1.15-2.46)]. 'Rotterdam' indication criteria used for MMS are appropriate. Predictors for extensive subclinical spread are important for patients' and surgeons' expectations prior to the operation about time span, defect size, reconstruction and possible associated morbidity. © 2012 The Authors. Journal of the European Academy of Dermatology and Venereology © 2012 European Academy of Dermatology and Venereology.
Kristunas, Caroline A; Smith, Karen L; Gray, Laura J
2017-03-07
The current methodology for sample size calculations for stepped-wedge cluster randomised trials (SW-CRTs) is based on the assumption of equal cluster sizes. However, as is often the case in cluster randomised trials (CRTs), the clusters in SW-CRTs are likely to vary in size, which in other designs of CRT leads to a reduction in power. The effect of an imbalance in cluster size on the power of SW-CRTs has not previously been reported, nor what an appropriate adjustment to the sample size calculation should be to allow for any imbalance. We aimed to assess the impact of an imbalance in cluster size on the power of a cross-sectional SW-CRT and recommend a method for calculating the sample size of a SW-CRT when there is an imbalance in cluster size. The effect of varying degrees of imbalance in cluster size on the power of SW-CRTs was investigated using simulations. The sample size was calculated using both the standard method and two proposed adjusted design effects (DEs), based on those suggested for CRTs with unequal cluster sizes. The data were analysed using generalised estimating equations with an exchangeable correlation matrix and robust standard errors. An imbalance in cluster size was not found to have a notable effect on the power of SW-CRTs. The two proposed adjusted DEs resulted in trials that were generally considerably over-powered. We recommend that the standard method of sample size calculation for SW-CRTs be used, provided that the assumptions of the method hold. However, it would be beneficial to investigate, through simulation, what effect the maximum likely amount of inequality in cluster sizes would be on the power of the trial and whether any inflation of the sample size would be required.
Ytre-Hauge, Sigmund; Husby, Jenny A; Magnussen, Inger J; Werner, Henrica M J; Salvesen, Øyvind O; Bjørge, Line; Trovik, Jone; Stefansson, Ingunn M; Salvesen, Helga B; Haldorsen, Ingfrid S
2015-03-01
The aim of this study was to explore the relation between preoperative tumor size based on magnetic resonance imaging (MRI) and the surgical pathologic staging parameters (deep myometrial invasion, cervical stroma invasion, and metastatic lymph nodes) and to assess the prognostic impact of tumor size in endometrial carcinomas. Interobserver variability for the different tumor size measurements was also assessed. Preoperative pelvic MRI of 212 patients with histologically confirmed endometrial carcinomas was read independently by 3 radiologists. Maximum tumor diameters were measured in 3 orthogonal planes (anteroposterior, transverse, and craniocaudal planes [CC]), and tumor volumes were estimated. Tumor size was analyzed in relation to surgical staging results and patient survival. The multivariate analyses were adjusted for preoperative risk status based on endometrial biopsy. Intraclass correlation coefficients and receiver operating characteristics curves for the different tumor measurements were also calculated. Anteroposterior tumor diameter independently predicted deep myometrial invasion (P < 0.001), whereas CC tumor diameter tended to independently predict lymph node metastases (P = 0.06). Based on receiver operating characteristic curves, the following tumor size cutoff values were identified: anteroposterior diameter greater than 2 cm predicted deep myometrial invasion (unadjusted odds ratio [OR], 12.4; P < 0.001; adjusted OR, 6.7; P < 0.001) and CC diameter greater than 4 cm predicted lymph node metastases (unadjusted OR, 6.2; P < 0.001; adjusted OR, 4.9; P = 0.009). Large tumor size was associated with reduced progression/recurrence-free survival (P ≤ 0.005 for all size parameters), and CC diameter had an independent impact on survival (adjusted hazards ratio, 1.04; P = 0.009). The interobserver variability for the different size measurements was very low (intraclass correlation coefficient, 0.78-0.85). Anteroposterior tumor diameter greater than 2 cm predicts deep myometrial invasion, and CC tumor diameter greater than 4 cm predicts lymph node metastases. Tumor size is a strong prognostic factor in endometrial carcinomas. Preoperative tumor measurements based on MRI may potentially improve preoperative risk stratification models and thus enable better tailored surgical treatment in endometrial cancer.
Yan, Danhua; Tao, Jing; Kisslinger, Kim; ...
2015-10-13
Here we develop a novel technique for preparing high quality Ti-doped hematite thin films for photoelectrochemical (PEC) water splitting, through sputtering deposition of metallic iron films from an iron target embedded with titanium (dopants) pellets, followed by a thermal oxidation step that turns the metal films into doped hematite. It is found that the hematite domain size can be tuned from ~10 nm to over 100 nm by adjusting the sputtering atmosphere from more oxidative to mostly inert. The better crystallinity at a larger domain size ensures excellent PEC water splitting performance, leading to record high photocurrent from pure planarmore » hematite thin films on FTO substrates. Titanium doping further enhances the PEC performance of hematite photoanodes. The photocurrent is improved by 50%, with a titanium dopant concentration as low as 0.5 atom%. As a result, it is also found that the role of the titanium dopant in improving the PEC performance is not apparently related to the films’ electrical conductivity which had been widely believed, but is more likely due to the passivation of surface defects by the titanium dopants.« less
A Secure and Efficient Scalable Secret Image Sharing Scheme with Flexible Shadow Sizes.
Xie, Dong; Li, Lixiang; Peng, Haipeng; Yang, Yixian
2017-01-01
In a general (k, n) scalable secret image sharing (SSIS) scheme, the secret image is shared by n participants and any k or more than k participants have the ability to reconstruct it. The scalability means that the amount of information in the reconstructed image scales in proportion to the number of the participants. In most existing SSIS schemes, the size of each image shadow is relatively large and the dealer does not has a flexible control strategy to adjust it to meet the demand of differen applications. Besides, almost all existing SSIS schemes are not applicable under noise circumstances. To address these deficiencies, in this paper we present a novel SSIS scheme based on a brand-new technique, called compressed sensing, which has been widely used in many fields such as image processing, wireless communication and medical imaging. Our scheme has the property of flexibility, which means that the dealer can achieve a compromise between the size of each shadow and the quality of the reconstructed image. In addition, our scheme has many other advantages, including smooth scalability, noise-resilient capability, and high security. The experimental results and the comparison with similar works demonstrate the feasibility and superiority of our scheme.
Low Complexity Compression and Speed Enhancement for Optical Scanning Holography
Tsang, P. W. M.; Poon, T.-C.; Liu, J.-P.; Kim, T.; Kim, Y. S.
2016-01-01
In this paper we report a low complexity compression method that is suitable for compact optical scanning holography (OSH) systems with different optical settings. Our proposed method can be divided into 2 major parts. First, an automatic decision maker is applied to select the rows of holographic pixels to be scanned. This process enhances the speed of acquiring a hologram, and also lowers the data rate. Second, each row of down-sampled pixels is converted into a one-bit representation with delta modulation (DM). Existing DM-based hologram compression techniques suffers from the disadvantage that a core parameter, commonly known as the step size, has to be determined in advance. However, the correct value of the step size for compressing each row of hologram is dependent on the dynamic range of the pixels, which could deviate significantly with the object scene, as well as OSH systems with different opical settings. We have overcome this problem by incorporating a dynamic step-size adjustment scheme. The proposed method is applied in the compression of holograms that are acquired with 2 different OSH systems, demonstrating a compression ratio of over two orders of magnitude, while preserving favorable fidelity on the reconstructed images. PMID:27708410
Factor weighting in DRASTIC modeling.
Pacheco, F A L; Pires, L M G R; Santos, R M B; Sanches Fernandes, L F
2015-02-01
Evaluation of aquifer vulnerability comprehends the integration of very diverse data, including soil characteristics (texture), hydrologic settings (recharge), aquifer properties (hydraulic conductivity), environmental parameters (relief), and ground water quality (nitrate contamination). It is therefore a multi-geosphere problem to be handled by a multidisciplinary team. The DRASTIC model remains the most popular technique in use for aquifer vulnerability assessments. The algorithm calculates an intrinsic vulnerability index based on a weighted addition of seven factors. In many studies, the method is subject to adjustments, especially in the factor weights, to meet the particularities of the studied regions. However, adjustments made by different techniques may lead to markedly different vulnerabilities and hence to insecurity in the selection of an appropriate technique. This paper reports the comparison of 5 weighting techniques, an enterprise not attempted before. The studied area comprises 26 aquifer systems located in Portugal. The tested approaches include: the Delphi consensus (original DRASTIC, used as reference), Sensitivity Analysis, Spearman correlations, Logistic Regression and Correspondence Analysis (used as adjustment techniques). In all cases but Sensitivity Analysis, adjustment techniques have privileged the factors representing soil characteristics, hydrologic settings, aquifer properties and environmental parameters, by leveling their weights to ≈4.4, and have subordinated the factors describing the aquifer media by downgrading their weights to ≈1.5. Logistic Regression predicts the highest and Sensitivity Analysis the lowest vulnerabilities. Overall, the vulnerability indices may be separated by a maximum value of 51 points. This represents an uncertainty of 2.5 vulnerability classes, because they are 20 points wide. Given this ambiguity, the selection of a weighting technique to integrate a vulnerability index may require additional expertise to be set up satisfactorily. Following a general criterion that weights must be proportional to the range of the ratings, Correspondence Analysis may be recommended as the best adjustment technique. Copyright © 2014 Elsevier B.V. All rights reserved.
Loweg, Lennard; Kutzner, Karl Philipp; Trost, Matthias; Hechtner, Marlene; Drees, Philipp; Pfeil, Joachim; Schneider, Michael
2018-02-01
Short-stem THA has become increasingly popular over the last decade. However, implantation technique differs from conventional THA and thus possibly involves a distinct learning curve. The purpose of this study was to evaluate the value of intraoperative radiography and the influence of the surgeon's experience on intraoperative adjustments in short-stem THA. A total of 287 consecutive short-stem THAs, operated by a total of 24 senior consultants, consultants and residents in training, were prospectively included. Intraoperative radiography was performed after trial reduction. Preoperative planning and intraoperative outcome with regard to positioning, sizing of components as well as resulting offset and leg length were compared. Frequency, reason and type of intraoperative adjustments were documented in relation to the surgeon's experience. Operation time was assessed. One hundred and fifty-six (54.4%) procedures were carried out by one of three senior consultants, and a total of nine consultants and 12 residents in training performed 105 (36.6%) and 26 (9.0%) operations, respectively. In 121 cases (42.2%), intraoperative adjustments were made following intraoperative radiography. Intraoperative adjustments of one or more components were made by senior consultants in 51 cases (32.7%), by consultants in 53 cases (50.5%) and by residents in 17 cases (65.4%), respectively. The most common cause was undersizing of the stem. Operation time varied markedly between groups of surgeons. Short-stem THA involves a learning curve. Intraoperative radiography is decisive for prevention of malpositioning and undersizing of components, as well as loss of offset and leg length discrepancies. Hence, it should be considered mandatory, especially for less experienced surgeons.
Cost estimation and analysis using the Sherpa Automated Mine Cost Engineering System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stebbins, P.E.
1993-09-01
The Sherpa Automated Mine Cost Engineering System is a menu-driven software package designed to estimate capital and operating costs for proposed surface mining operations. The program is engineering (as opposed to statistically) based, meaning that all equipment, manpower, and supply requirements are determined from deposit geology, project design and mine production information using standard engineering techniques. These requirements are used in conjunction with equipment, supply, and labor cost databases internal to the program to estimate all associated costs. Because virtually all on-site cost parameters are interrelated within the program, Sherpa provides an efficient means of examining the impact of changesmore » in the equipment mix on total capital and operating costs. If any aspect of the operation is changed, Sherpa immediately adjusts all related aspects as necessary. For instance, if the user wishes to examine the cost ramifications of selecting larger trucks, the program not only considers truck purchase and operation costs, it also automatically and immediately adjusts excavator requirements, operator and mechanic needs, repair facility size, haul road construction and maintenance costs, and ancillary equipment specifications.« less
Simultaneous Comparison of Two Roller Compaction Techniques and Two Particle Size Analysis Methods.
Saarinen, Tuomas; Antikainen, Osmo; Yliruusi, Jouko
2017-11-01
A new dry granulation technique, gas-assisted roller compaction (GARC), was compared with conventional roller compaction (CRC) by manufacturing 34 granulation batches. The process variables studied were roll pressure, roll speed, and sieve size of the conical mill. The main quality attributes measured were granule size and flow characteristics. Within granulations also the real applicability of two particle size analysis techniques, sieve analysis (SA) and fast imaging technique (Flashsizer, FS), was tested. All granules obtained were acceptable. In general, the particle size of GARC granules was slightly larger than that of CRC granules. In addition, the GARC granules had better flowability. For example, the tablet weight variation of GARC granules was close to 2%, indicating good flowing and packing characteristics. The comparison of the two particle size analysis techniques showed that SA was more accurate in determining wide and bimodal size distributions while FS showed narrower and mono-modal distributions. However, both techniques gave good estimates for mean granule sizes. Overall, SA was a time-consuming but accurate technique that provided reliable information for the entire granule size distribution. By contrast, FS oversimplified the shape of the size distribution, but nevertheless yielded acceptable estimates for mean particle size. In general, FS was two to three orders of magnitude faster than SA.
Kinetics of red blood cell rouleaux formation studied by light scattering
NASA Astrophysics Data System (ADS)
Szołna-Chodór, Alicja; Bosek, Maciej; Grzegorzewski, Bronisław
2015-02-01
Red blood cell (RBC) rouleaux formation was experimentally studied using a light scattering technique. The suspensions of RBCs were obtained from the blood of healthy donors. Hematocrit of the samples was adjusted ranging from 1% to 4%. Measurements of the intensity of the coherent component of light scattered by the suspensions were performed and the scattering coefficient of the suspensions was determined. The number of RBCs per rouleaux was obtained using anomalous diffraction theory. The technique was used to show the effect of time, hematocrit, and sample thickness on the process. The number of cells per rouleaux first increases linearly, reaches a critical value at ˜3 cells per rouleaux, and then a further increase in the rouleaux size is observed. The kinetic constant of the rouleaux growth in the linear region is found to be independent of hematocrit. The aggregation rate increases as the sample thickness increases. The time at which the critical region appears strongly decreases as the hematocrit of the suspension increases.
Vedelago, J; Mattea, F; Valente, M
2018-03-01
The use and implementation of nanoparticles in medicine has grown exponentially in the last twenty years. Their main applications include drug delivery, theranostics, tissue engineering and magneto function. Dosimetry techniques can take advantage of inorganic nanoparticles properties and their combination with gel dosimetry techniques could be used as a first step for their later inclusion in radio-diagnostics or radiotherapy treatments. The present study presents preliminary results of properly synthesized and purified silver nanoparticles integration with Fricke gel dosimeters. Used nanoparticles presented mean sizes ranging from 2 to 20 nm, with a lognormal distribution. Xylenol orange concentration in Fricke gel dosimeter was adjust in order to allow sample's optical readout, accounting nanoparticles plasmon. Dose enhancement was assessed irradiating dosimeters setting X-ray beams energies below and above silver K-edge. Monte Carlo simulations were used to estimate the dose enhancement in the experiments and compare with the trend obtained in the experimental results. Copyright © 2018 Elsevier Ltd. All rights reserved.
Deng, Zhi-De; Lisanby, Sarah H; Peterchev, Angel V
2013-12-01
Understanding the relationship between the stimulus parameters of electroconvulsive therapy (ECT) and the electric field characteristics could guide studies on improving risk/benefit ratio. We aimed to determine the effect of current amplitude and electrode size and spacing on the ECT electric field characteristics, compare ECT focality with magnetic seizure therapy (MST), and evaluate stimulus individualization by current amplitude adjustment. Electroconvulsive therapy and double-cone-coil MST electric field was simulated in a 5-shell spherical human head model. A range of ECT electrode diameters (2-5 cm), spacing (1-25 cm), and current amplitudes (0-900 mA) was explored. The head model parameters were varied to examine the stimulus current adjustment required to compensate for interindividual anatomical differences. By reducing the electrode size, spacing, and current, the ECT electric field can be more focal and superficial without increasing scalp current density. By appropriately adjusting the electrode configuration and current, the ECT electric field characteristics can be made to approximate those of MST within 15%. Most electric field characteristics in ECT are more sensitive to head anatomy variation than in MST, especially for close electrode spacing. Nevertheless, ECT current amplitude adjustment of less than 70% can compensate for interindividual anatomical variability. The strength and focality of ECT can be varied over a wide range by adjusting the electrode size, spacing, and current. If desirable, ECT can be made as focal as MST while using simpler stimulation equipment. Current amplitude individualization can compensate for interindividual anatomical variability.
50 CFR 648.165 - Bluefish minimum fish sizes.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 50 Wildlife and Fisheries 12 2014-10-01 2014-10-01 false Bluefish minimum fish sizes. 648.165... Measures for the Atlantic Bluefish Fishery § 648.165 Bluefish minimum fish sizes. If the MAFMC determines through its annual review or framework adjustment process that minimum fish sizes are necessary to ensure...
50 CFR 648.165 - Bluefish minimum fish sizes.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 50 Wildlife and Fisheries 12 2013-10-01 2013-10-01 false Bluefish minimum fish sizes. 648.165... Measures for the Atlantic Bluefish Fishery § 648.165 Bluefish minimum fish sizes. If the MAFMC determines through its annual review or framework adjustment process that minimum fish sizes are necessary to ensure...
50 CFR 648.165 - Bluefish minimum fish sizes.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 50 Wildlife and Fisheries 12 2012-10-01 2012-10-01 false Bluefish minimum fish sizes. 648.165... Measures for the Atlantic Bluefish Fishery § 648.165 Bluefish minimum fish sizes. If the MAFMC determines through its annual review or framework adjustment process that minimum fish sizes are necessary to ensure...
50 CFR 648.162 - Minimum fish sizes.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 50 Wildlife and Fisheries 8 2010-10-01 2010-10-01 false Minimum fish sizes. 648.162 Section 648... Atlantic Bluefish Fishery § 648.162 Minimum fish sizes. If the Council determines through its annual review or framework adjustment process that minimum fish sizes are necessary to assure that the fishing...
Mills, Britain A.; Harris, T. Robert
2012-01-01
Objective: This study was conducted to examine discrepancies in alcohol consumption estimates between a self-reported standard quantity—frequency measure and an adjusted version based on respondents’ typically used container size. Method: Using a multistage cluster sample design, 5,224 Hispanic individuals 18 years of age and older were selected from the household population in five metropolitan areas of the United States: Miami, New York, Philadelphia, Houston, and Los Angeles. The survey-weighted response rate was 76%. Personal interviews lasting an average of 1 hour were conducted in respondents’ homes in either English or Spanish. Results: The overall effect of container adjustment was to increase estimates of ethanol consumption by 68% for women (range across Hispanic groups: 17%–99%) and 30% for men (range: 14%–42%). With the exception of female Cuban American, Mexican American, and South/Central American beer drinkers and male Cuban American wine drinkers, all percentage differences between unadjusted and container-adjusted estimates were positive. Second, container adjustments produced the largest change for volume of distilled spirits, followed by wine and beer. Container size adjustments generally produced larger percentage increases in consumption estimates for the higher volume drinkers, especially the upper tertile of female drinkers. Conclusions: Self-reported alcohol consumption based on standard drinks underreports consumption when compared with reports based on the amount of alcohol poured into commonly used containers. PMID:22152669
Body size in early life and risk of lymphoid malignancies and histological subtypes in adulthood.
Yang, TienYu Owen; Cairns, Benjamin J; Kroll, Mary E; Reeves, Gillian K; Green, Jane; Beral, Valerie
2016-07-01
Risk of adult lymphoid malignancy is associated with recent adiposity. Some have reported apparent associations with adiposity in childhood or early adulthood, but whether these associations are independent of recent adiposity is unknown. Birth weight, body size at age 10 years, clothes size at age 20 years, and recent body mass index (BMI) were recorded in 745,273 UK women, mean age 60.1 (SD 4.9) at baseline, without prior cancer. They were followed for 11 years, during which time 5,765 lymphoid malignancies occurred. Using Cox regression, a higher risk of lymphoid malignancy was strongly associated with higher recent BMI (RR=1.33, 95%CI 1.17-1.51, for BMI 35+ vs <22.5 kg/m(2)), and this association remained essentially unchanged after adjustment for birth weight and body size at 10. Higher lymphoid malignancy risk was also associated with large size at birth, at age 10, and at age 20 years, but after adjustment for recent BMI, the significance of the associations with large size at birth and at age 10 years was sufficiently reduced that residual confounding by adult BMI could not be excluded; a weak association with large size at 20 years remained (adjusted RR =1.17, 95%CI 1.10-1.24 for large size at age 20 vs. medium or small size). We found no strong evidence of histological specificity in any of these associations. In conclusion, our findings suggest a possible role of adiposity throughout adulthood in the risk of lymphoid malignancy, but the independent contribution of body size at birth and during childhood appears to be small. © 2016 The Authors International Journal of Cancer published by John Wiley & Sons Ltd on behalf of UICC.
Temporal profile of body temperature in acute ischemic stroke: relation to infarct size and outcome.
Geurts, Marjolein; Scheijmans, Féline E V; van Seeters, Tom; Biessels, Geert J; Kappelle, L Jaap; Velthuis, Birgitta K; van der Worp, H Bart
2016-11-21
High body temperatures after ischemic stroke have been associated with larger infarct size, but the temporal profile of this relation is unknown. We assess the relation between temporal profile of body temperature and infarct size and functional outcome in patients with acute ischemic stroke. In 419 patients with acute ischemic stroke we assessed the relation between body temperature on admission and during the first 3 days with both infarct size and functional outcome. Infarct size was measured in milliliters on CT or MRI after 3 days. Poor functional outcome was defined as a modified Rankin Scale score ≥3 at 3 months. Body temperature on admission was not associated with infarct size or poor outcome in adjusted analyses. By contrast, each additional 1.0 °C in body temperature on day 1 was associated with 0.31 ml larger infarct size (95% confidence interval (CI) 0.04-0.59), on day 2 with 1.13 ml larger infarct size(95% CI, 0.83-1.43), and on day 3 with 0.80 ml larger infarct size (95% CI, 0.48-1.12), in adjusted linear regression analyses. Higher peak body temperatures on days two and three were also associated with poor outcome (adjusted relative risks per additional 1.0 °C in body temperature, 1.52 (95% CI, 1.17-1.99) and 1.47 (95% CI, 1.22-1.77), respectively). Higher peak body temperatures during the first days after ischemic stroke, rather than on admission, are associated with larger infarct size and poor functional outcome. This suggests that prevention of high temperatures may improve outcome if continued for at least 3 days.
ERIC Educational Resources Information Center
Green, Leonard; Myerson, Joel; Shah, Anuj K.; Estle, Sara J.; Holt, Daniel D.
2007-01-01
The current experiment examined whether adjusting-amount and adjusting-delay procedures provide equivalent measures of discounting. Pigeons' discounting on the two procedures was compared using a within-subject yoking technique in which the indifference point (number of pellets or time until reinforcement) obtained with one procedure determined…
Flowability of granular materials with industrial applications - An experimental approach
NASA Astrophysics Data System (ADS)
Torres-Serra, Joel; Romero, Enrique; Rodríguez-Ferran, Antonio; Caba, Joan; Arderiu, Xavier; Padullés, Josep-Manel; González, Juanjo
2017-06-01
Designing bulk material handling equipment requires a thorough understanding of the mechanical behaviour of powders and grains. Experimental characterization of granular materials is introduced focusing on flowability. A new prototype is presented which performs granular column collapse tests. The device consists of a channel whose design accounts for test inspection using visualization techniques and load measurements. A reservoir is attached where packing state of the granular material can be adjusted before run-off to simulate actual handling conditions by fluidisation and deaeration of the pile. Bulk materials on the market, with a wide range of particle sizes, can be tested with the prototype and the results used for classification in terms of flowability to improve industrial equipment selection processes.
Chameleon Coatings: Adaptive Surfaces to Reduce Friction and Wear in Extreme Environments
NASA Astrophysics Data System (ADS)
Muratore, C.; Voevodin, A. A.
2009-08-01
Adaptive nanocomposite coating materials that automatically and reversibly adjust their surface composition and morphology via multiple mechanisms are a promising development for the reduction of friction and wear over broad ranges of ambient conditions encountered in aerospace applications, such as cycling of temperature and atmospheric composition. Materials selection for these composites is based on extensive study of interactions occurring between solid lubricants and their surroundings, especially with novel in situ surface characterization techniques used to identify adaptive behavior on size scales ranging from 10-10 to 10-4 m. Recent insights on operative solid-lubricant mechanisms and their dependency upon the ambient environment are reviewed as a basis for a discussion of the state of the art in solid-lubricant materials.
Sightability adjustment methods for aerial surveys of wildlife populations
Steinhorst, R.K.; Samuel, M.D.
1989-01-01
Aerial surveys are routinely conducted to estimate the abundance of wildlife species and the rate of population change. However, sightability of animal groups is acknowledged as a significant source of bias in these estimates. Recent research has focused on the development of sightability models to predict the probability of sighting groups under various conditions. Given such models, we show how sightability can be incorporated into the estimator of population size as a probability of response using standard results from sample surveys. We develop formulas for the cases where the sighting probability must be estimated. An example, using data from a helicopter survey of moose in Alberta (Jacobson, Alberta Oil Sands Research Project Report, 1976), is given to illustrate the technique.
Westendorff, Carsten; Kaminsky, Jan; Ernemann, Ulrike; Reinert, Siegmar; Hoffmann, Jürgen
2007-02-01
Resection of large intraosseous sphenoid wing meningiomas is traditionally associated with significant morbidity. Rapid prototyping techniques have become widely used for treatment planning. Yet, the transfer of a treatment plan into the intraoperative situs strongly depends on the experience of the individual surgeon. Extensive resection with orbital decompression was planned and performed on the basis of rapid prototyping and surgical navigation techniques in a 44-year-old woman presenting with a large sphenoid wing meningioma on the right infiltrating the orbit. Tumor resection was simulated on a stereolithography model of the patient's head. The stereolithography model was scanned using computed tomography (CT) and the defect geometry was used to create a custom-made titanium implant. The implant consisted of a solid titanium core and a spot-welded titanium mesh surrounding the core, allowing for minor intraoperative adjustments of the implant size by reducing the mesh size. The stereolithography model with the incorporated implant was CT scanned again and the CT data were fused with the patient's original CT data. The implant borders indicating the resection borders were marked within the patient's CT data set. This treatment plan was transferred to an optical navigation system. Intraoperatively, tumor resection was performed using surgical navigation. In the presented case report, the combination of computer-assisted planning using rapid prototyping techniques and image-guided surgery allowed for an extensive tumor resection precisely according to a preoperative treatment plan in a patient presenting with a large intraosseous sphenoid wing meningioma. A larger clinical series with a long-term follow-up period will be needed to determine the reproducibility.
Burtch, Stephanie R; Sameti, Mahyar; Olmstead, Richard T; Bashur, Chris A
2018-05-01
The development of tissue-engineered products has been limited by lack of a perfused microvasculature that delivers nutrients and maintains cell viability. Current strategies to promote vascularization such as additive three-dimensional printing techniques have limitations. This study validates the use of an ultra-fast laser subtractive printing technique to generate capillary-sized channels in hydrogels prepopulated with cells by demonstrating cell viability relative to the photodisrupted channels in the gel. The system can move the focal spot laterally in the gel at a rate of 2500 mm/s by using a galvanometric scanner to raster the in plane focal spot. A Galilean telescope allows z-axis movement. Blended hydrogels of polyethylene glycol and collagen with a range of optical clarities, mechanical properties and swelling behavior were tested to demonstrate that the subtractive printing process for writing vascular channels is compatible with all of the blended hydrogels tested. Channel width and patterns were controlled by adjusting the laser energy and focal spot positioning, respectively. After treatment, high cell viability was observed at distances greater than or equal to 18 μm from the fabricated channels. Overall, this study demonstrates a flexible technique that has the potential to rapidly generate channels in tissue-engineered constructs. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
What matters after sleeve gastrectomy: patient characteristics or surgical technique?
Dhar, Vikrom K; Hanseman, Dennis J; Watkins, Brad M; Paquette, Ian M; Shah, Shimul A; Thompson, Jonathan R
2018-03-01
The impact of operative technique on outcomes in laparoscopic sleeve gastrectomy has been explored previously; however, the relative importance of patient characteristics remains unknown. Our aim was to characterize national variability in operative technique for laparoscopic sleeve gastrectomy and determine whether patient-specific factors are more critical to predicting outcomes. We queried the database of the Metabolic and Bariatric Surgery Accreditation and Quality Improvement Program for laparoscopic sleeve gastrostomies performed in 2015 (n = 88,845). Logistic regression models were used to determine predictors of postoperative outcomes. In 2015, >460 variations of laparoscopic sleeve gastrectomy were performed based on combinations of bougie size, distance from the pylorus, use of staple line reinforcement, and oversewing of the staple line. Despite such substantial variability, technique variants were not predictive of outcomes, including perioperative morbidity, leak, or bleeding (all P ≥ .05). Instead, preoperative patient characteristics were found to be more predictive of these outcomes after laparoscopic sleeve gastrectomy. Only history of gastroesophageal disease (odds ratio 1.44, 95% confidence interval 1.08-1.91, P < .01) was associated with leak. Considerable variability exists in technique among surgeons nationally, but patient characteristics are more predictive of adverse outcomes after laparoscopic sleeve gastrectomy. Bundled payments and reimbursement policies should account for patient-specific factors in addition to current accreditation and volume thresholds when deciding risk-adjustment strategies. Copyright © 2018 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Hussain, Tariq; Liu, Yan; Huang, Fenglei; Duan, Zhuoping
2016-01-01
The change in shock sensitivity of explosives having various explosive grain sizes is discussed. Along with other parameters, explosive grain size is one of the key parameters controlling the macroscopic behavior of shocked pressed explosives. Ignition and growth reactive flow modeling is performed for the shock initiation experiments carried out by using the in situ manganin piezoresistive pressure gauge technique to investigate the influences of the octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) particle size on the shock initiation and the subsequent detonation growth process for the three explosive formulations of pressed PBXC03 (87% HMX, 7% 1,3,5-trichloro-2,4,6-trinitrobenzene (TATB), 6% Viton by weight). All of the formulation studied had the same density but different explosive grain sizes. A set of ignition and growth parameters was obtained for all three formulations. Only the coefficient G1 of the first growth term in the reaction rate equation was varied with the grain size; all other parameters were kept the same for all formulations. It was found that G1 decreases almost linearly with HMX particle size for PBXC03. However, the equation of state (EOS) for solid explosive had to be adjusted to fit the experimental data. Both experimental and numerical simulation results show that the shock sensitivity of PBXC03 decreases with increasing HMX particle size for the sustained pressure pulses (around 4 GPa) as obtained in the experiment. This result is in accordance with the results reported elsewhere in literature. For future work, a better approach may be to find standard solid Grüneisen EOS and product Jones-Wilkins-Lee (JWL) EOS for each formulation for the best fit to the experimental data.
Goetz, H; Kuschel, M; Wulff, T; Sauber, C; Miller, C; Fisher, S; Woodward, C
2004-09-30
Protein analysis techniques are developing fast due to the growing number of proteins obtained by recombinant DNA techniques. In the present paper we compare selected techniques, which are used for protein sizing, quantitation and molecular weight determination: sodium dodecylsulfate-polyacrylamide gel electrophoresis (SDS-PAGE), lab-on-a-chip or microfluidics technology (LoaC), size exclusion chromatography (SEC) and mass spectrometry (MS). We compare advantages and limitations of each technique in respect to different application areas, analysis time, protein sizing and quantitation performance.
50 CFR 648.126 - Scup minimum fish sizes.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 50 Wildlife and Fisheries 12 2014-10-01 2014-10-01 false Scup minimum fish sizes. 648.126 Section... Scup Fishery § 648.126 Scup minimum fish sizes. (a) Moratorium (commercially) permitted vessels. The... whole fish or any part of a fish found in possession, e.g., fillets. These minimum sizes may be adjusted...
50 CFR 648.126 - Scup minimum fish sizes.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 50 Wildlife and Fisheries 12 2012-10-01 2012-10-01 false Scup minimum fish sizes. 648.126 Section... Scup Fishery § 648.126 Scup minimum fish sizes. (a) Moratorium (commercially) permitted vessels. The... whole fish or any part of a fish found in possession, e.g., fillets. These minimum sizes may be adjusted...
50 CFR 648.126 - Scup minimum fish sizes.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 50 Wildlife and Fisheries 12 2013-10-01 2013-10-01 false Scup minimum fish sizes. 648.126 Section... Scup Fishery § 648.126 Scup minimum fish sizes. (a) Moratorium (commercially) permitted vessels. The... whole fish or any part of a fish found in possession, e.g., fillets. These minimum sizes may be adjusted...
Code of Federal Regulations, 2010 CFR
2010-04-01
... definitions-family size not known (actual or prospective tenants). 81.18 Section 81.18 Housing and Urban... CORPORATION (FREDDIE MAC) Housing Goals § 81.18 Affordability—Income level definitions—family size not known... moderate-income families where family size is not known to the GSE, income will be adjusted using unit size...
Housing wealth and mortality: A register linkage study of the Finnish population.
Laaksonen, Mikko; Tarkiainen, Lasse; Martikainen, Pekka
2009-09-01
In many countries home ownership is the main form of property and covers a major part of people's possessions. Since overall wealth is difficult to measure, many health studies have used home ownership as an indicator of wealth and material resources. However, most studies have measured housing wealth with a simple dichotomous measure of home ownership. We examined the associations between three different measures of housing wealth and overall mortality, separating subsidized renters and private renters, and using floor area and the number of rooms as measures of dwelling size. We further examined whether other socioeconomic factors, level of urbanisation of the region of residence, and household composition account for the found associations. Finns aged 35-79 years at the end of 1999 were followed up until the end of 2004. Data were drawn from various registers combined by Statistics Finland and linked with death records. The age-adjusted hazard ratio for mortality among subsidized renters compared to owner-occupiers was 2.26 in men and 1.87 in women. However, also private renters had clearly higher mortality than owner-occupiers, with the excess mortality of 92% in men and 61% in women. Both measures of home size were also strongly associated with mortality, with the excess risk of 1.7-3.0 in the lowest home size quintile compared to the highest. Adjusting for socioeconomic factors and mutually for all housing wealth measures considerably attenuated the associations. Further adjustment for urbanisation had no effect whereas adjustment for household size, marital status and living arrangements attenuated the associations of the two home size measures and mortality. However, a clear association remained between all housing wealth measures and mortality after all adjustments. Housing wealth summarises one's material circumstances over a prolonged period of time. Measures of housing wealth may therefore provide useful social classifications for studies on poor health and mortality especially in older age groups where most deaths occur.
Bei, Yong-Yan; Zhou, Xiao-Feng; You, Ben-Gang; Yuan, Zhi-Qiang; Chen, Wei-Liang; Xia, Peng; Liu, Yang; Jin, Yong; Hu, Xiao-Juan; Zhu, Qiao-Ling; Zhang, Chun-Ge; Zhang, Xue-Nong; Zhang, Liang
2013-01-01
Lactose-palmitoyl-trimethyl-chitosan (Lac-TPCS), a novel amphipathic self-assembled polymer, was synthesized for administration of insoluble drugs to reduce their adverse effects. The central composite design was used to study the preparation technique of harmine (HM)-loaded self-assembled micelles based on Lac-TPCS (Lac-TPCS/HM). Three preparation methods and single factors were screened, including solvent type, HM amount, hydration volume, and temperature. The optimal preparation technique was identified after investigating the influence of two independent factors, namely, HM amount and hydration volume, on four indexes, ie, encapsulation efficiency (EE), drug-loading amount (LD), particle size, and polydispersity index (PDI). Analysis of variance showed a high coefficient of determination of 0.916 to 0.994, thus ensuring a satisfactory adjustment of the predicted prescription. The maximum predicted values of the optimal prescription were 91.62%, 14.20%, 183.3 nm, and 0.214 for EE, LD, size, and PDI, respectively, when HM amount was 1.8 mg and hydration volume was 9.6 mL. HM-loaded micelles were successfully characterized by Fourier-transform infrared spectroscopy, differential scanning calorimetry, X-ray diffraction, and a fluorescence-quenching experiment. Sustained release of Lac-TPCS/HM reached 65.3% in 72 hours at pH 7.4, while free HM released about 99.7% under the same conditions.
Surface wettability of silicon substrates enhanced by laser ablation
NASA Astrophysics Data System (ADS)
Tseng, Shih-Feng; Hsiao, Wen-Tse; Chen, Ming-Fei; Huang, Kuo-Cheng; Hsiao, Sheng-Yi; Lin, Yung-Sheng; Chou, Chang-Pin
2010-11-01
Laser-ablation techniques have been widely applied for removing material from a solid surface using a laser-beam irradiating apparatus. This paper presents a surface-texturing technique to create rough patterns on a silicon substrate using a pulsed Nd:YAG laser system. The different degrees of microstructure and surface roughness were adjusted by the laser fluence and laser pulse duration. A scanning electron microscope (SEM) and a 3D confocal laser-scanning microscope are used to measure the surface micrograph and roughness of the patterns, respectively. The contact angle variations between droplets on the textured surface were measured using an FTA 188 video contact angle analyzer. The results indicate that increasing the values of laser fluence and laser pulse duration pushes more molten slag piled around these patterns to create micro-sized craters and leads to an increase in the crater height and surface roughness. A typical example of a droplet on a laser-textured surface shows that the droplet spreads very quickly and almost disappears within 0.5167 s, compared to a contact angle of 47.9° on an untextured surface. This processing technique can also be applied to fabricating Si solar panels to increase the absorption efficiency of light.
Mesoporous Akaganeite of Adjustable Pore Size Synthesized using Mixed Templates
NASA Astrophysics Data System (ADS)
Zhang, Y.; Ge, D. L.; Ren, H. P.; Fan, Y. J.; Wu, L. M.; Sun, Z. X.
2017-12-01
Mesoporous akaganeite with large and adjustable pore size was synthesized through a co-template method, which was achieved by the combined interaction between PEG2000 and alkyl amines with different lengths of the straight carbon chain. The characterized results indicate that the synthesized samples show comparatively narrow BJH pore size distributions and centered at 14.3 nm when PEG and HEPA was used, and it could be enlarged to 16.8 and 19.4 nm respectively through changing the alkyl amines to DDA and HDA. Meanwhile, all the synthesized akaganeite possess relativity high specific surface area ranging from 183 to 281 m2/g and high total pore volume of 0.98 to 1.5 cm3/g. A possible mechanism leading to the pore size changing was also proposed.
Association between wood cooking fuel and maternal hypertension at delivery in central East India.
Wylie, Blair J; Singh, Mrigendra P; Coull, Brent A; Quinn, Ashlinn; Yeboah-Antwi, Kojo; Sabin, Lora; Hamer, Davidson H; Singh, Neeru; MacLeod, William B
2015-01-01
Smoke from burning of biomass fuels has been linked with adverse pregnancy outcomes and hypertension among nonpregnant subjects; association with hypertension during pregnancy has not been well studied. We evaluated whether the use of wood cooking fuel increases the risk of maternal hypertension at delivery compared to gas which burns with less smoke. Information on fuel use and blood pressure was available for analysis from a cross-sectional survey of 1369 pregnant women recruited at delivery in India. Compared to gas users, women using wood as fuel had on average lower mean arterial pressure (adjusted effect size - 2.0 mmHg; 95% CI: -3.77, -0.31) and diastolic blood pressure (adjusted effect size -1.96 mmHg; 95% CI: -3.60, -0.30) at delivery. Risk of hypertension (systolic >139 mmHg or diastolic >89 mmHg) was 14.6% for wood users compared to 19.6% for gas users although this did not reach significance after adjustment, using propensity score techniques, for factors that make wood and gas users distinct (adjusted prevalence ratio 0.76; 95% CI: 0.49, 1.17). Combustion products from the burning of biomass fuels are similar to those released with tobacco smoking, which has been linked with a reduced risk for preeclampsia. The direction of our findings suggests the possibility of a similar effect for biomass cook smoke. Whether clean cooking interventions being promoted by international advocacy organizations will impact hypertension in pregnancy warrants further analysis as hypertension remains a leading cause of maternal death worldwide and cooking with biomass fuels is widespread.
An experimental result of estimating an application volume by machine learning techniques.
Hasegawa, Tatsuhito; Koshino, Makoto; Kimura, Haruhiko
2015-01-01
In this study, we improved the usability of smartphones by automating a user's operations. We developed an intelligent system using machine learning techniques that periodically detects a user's context on a smartphone. We selected the Android operating system because it has the largest market share and highest flexibility of its development environment. In this paper, we describe an application that automatically adjusts application volume. Adjusting the volume can be easily forgotten because users need to push the volume buttons to alter the volume depending on the given situation. Therefore, we developed an application that automatically adjusts the volume based on learned user settings. Application volume can be set differently from ringtone volume on Android devices, and these volume settings are associated with each specific application including games. Our application records a user's location, the volume setting, the foreground application name and other such attributes as learning data, thereby estimating whether the volume should be adjusted using machine learning techniques via Weka.
Dimension Yields from Yellow-Poplar Lumber.
1984-06-01
the poor SP Split (includes end checks longer face and then on the good face. than 4 in.) - - The boards and each of their SW Sapwood + + defects were...Cutting Size Random SA = surface area of cutting width Adjustment Adjusted Y-ekd in square inches Length Width reading reading Using the previous...cutting sizes from 4 4 surface area of a 57- by 4-inch FAS yellow-poplar lumber cutting is 1.583 square feet: 3551.58 = 224 cuttings per 1.000 Cutting
Prakash, Priyanka; Gilman, Matthew D.; Shepard, Jo-Anne O.; Digumarthy, Subba R.
2010-01-01
Objective To assess the effects of radiation dose reduction in the chest CT using a weight-based adjustment of the automatic exposure control (AEC) technique. Materials and Methods With Institutional Review Board Approval, 60 patients (mean age, 59.1 years; M:F = 35:25) and 57 weight-matched patients (mean age, 52.3 years, M:F = 25:32) were scanned using a weight-adjusted AEC and non-weight-adjusted AEC, respectively on a 64-slice multidetector CT with a 0.984:1 pitch, 0.5 second rotation time, 40 mm table feed/rotation, and 2.5 mm section thickness. Patients were categorized into 3 weight categories; < 60 kg (n = 17), 60-90 kg (n = 52), and > 90 kg (n = 48). Patient weights, scanning parameters, CT dose index volumes (CTDIvol) and dose length product (DLP) were recorded, while effective dose (ED) was estimated. Image noise was measured in the descending thoracic aorta. Data were analyzed using a standard statistical package (SAS/STAT) (Version 9.1, SAS institute Inc, Cary, NC). Results Compared to the non-weight-adjusted AEC, the weight-adjusted AEC technique resulted in an average decrease of 29% in CTDIvol and a 27% effective dose reduction (p < 0.0001). With weight-adjusted AEC, the CTDIvol decreased to 15.8, 15.9, and 27.3 mGy for the < 60, 60-90 and > 91 kg weight groups, respectively, compared to 20.3, 27.9 and 32.8 mGy, with non-weight-adjusted AEC. No significant difference was observed for objective image noise between the chest CT acquired with the non-weight-adjusted (15.0 ± 3.1) and weight-adjusted (16.1 ± 5.6) AEC techniques (p > 0.05). Conclusion The results of this study suggest that AEC should be tailored according to patient weight. Without weight-based adjustment of AEC, patients are exposed to a 17 - 43% higher radiation-dose from a chest CT. PMID:20046494
Prakash, Priyanka; Kalra, Mannudeep K; Gilman, Matthew D; Shepard, Jo-Anne O; Digumarthy, Subba R
2010-01-01
To assess the effects of radiation dose reduction in the chest CT using a weight-based adjustment of the automatic exposure control (AEC) technique. With Institutional Review Board Approval, 60 patients (mean age, 59.1 years; M:F = 35:25) and 57 weight-matched patients (mean age, 52.3 years, M:F = 25:32) were scanned using a weight-adjusted AEC and non-weight-adjusted AEC, respectively on a 64-slice multidetector CT with a 0.984:1 pitch, 0.5 second rotation time, 40 mm table feed/rotation, and 2.5 mm section thickness. Patients were categorized into 3 weight categories; < 60 kg (n = 17), 60-90 kg (n = 52), and > 90 kg (n = 48). Patient weights, scanning parameters, CT dose index volumes (CTDIvol) and dose length product (DLP) were recorded, while effective dose (ED) was estimated. Image noise was measured in the descending thoracic aorta. Data were analyzed using a standard statistical package (SAS/STAT) (Version 9.1, SAS institute Inc, Cary, NC). Compared to the non-weight-adjusted AEC, the weight-adjusted AEC technique resulted in an average decrease of 29% in CTDIvol and a 27% effective dose reduction (p < 0.0001). With weight-adjusted AEC, the CTDIvol decreased to 15.8, 15.9, and 27.3 mGy for the < 60, 60-90 and > 91 kg weight groups, respectively, compared to 20.3, 27.9 and 32.8 mGy, with non-weight-adjusted AEC. No significant difference was observed for objective image noise between the chest CT acquired with the non-weight-adjusted (15.0 +/- 3.1) and weight-adjusted (16.1 +/- 5.6) AEC techniques (p > 0.05). The results of this study suggest that AEC should be tailored according to patient weight. Without weight-based adjustment of AEC, patients are exposed to a 17 - 43% higher radiation-dose from a chest CT.
Volunteering by older adults and risk of mortality: a meta-analysis.
Okun, Morris A; Yeung, Ellen WanHeung; Brown, Stephanie
2013-06-01
Organizational volunteering has been touted as an effective strategy for older adults to help themselves while helping others. Extending previous reviews, we carried out a meta-analysis of the relation between organizational volunteering by late-middle-aged and older adults (minimum age = 55 years old) and risk of mortality. We focused on unadjusted effect sizes (i.e., bivariate relations), adjusted effect sizes (i.e., controlling for other variables such as health), and interaction effect sizes (e.g., the joint effect of volunteering and religiosity). For unadjusted effect sizes, on average, volunteering reduced mortality risk by 47%, with a 95% confidence interval ranging from 38% to 55%. For adjusted effect sizes, on average, volunteering reduced mortality risk by 24%, with a 95% confidence interval ranging from 16% to 31%. For interaction effect sizes, we found preliminary support that as public religiosity increases, the inverse relation between volunteering and mortality risk becomes stronger. The discussion identifies several unresolved issues and directions for future research. PsycINFO Database Record (c) 2013 APA, all rights reserved.
Distribution of the two-sample t-test statistic following blinded sample size re-estimation.
Lu, Kaifeng
2016-05-01
We consider the blinded sample size re-estimation based on the simple one-sample variance estimator at an interim analysis. We characterize the exact distribution of the standard two-sample t-test statistic at the final analysis. We describe a simulation algorithm for the evaluation of the probability of rejecting the null hypothesis at given treatment effect. We compare the blinded sample size re-estimation method with two unblinded methods with respect to the empirical type I error, the empirical power, and the empirical distribution of the standard deviation estimator and final sample size. We characterize the type I error inflation across the range of standardized non-inferiority margin for non-inferiority trials, and derive the adjusted significance level to ensure type I error control for given sample size of the internal pilot study. We show that the adjusted significance level increases as the sample size of the internal pilot study increases. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Silva, Simonete; Bustamante, Alcibíades; Nevill, Alan; Katzmarzyk, Peter T.; Freitas, Duarte; Prista, António; Maia, José
2016-01-01
Children from developed and developing countries differ in their body size and shape due to marked differences across their life history caused by social, economic and cultural differences which are also linked to their motor performance (MP). We used allometric models to identify size/shape characteristics associated with MP tests between Brazilian and Peruvian schoolchildren. A total of 4,560 subjects, 2,385 girls and 2,175 boys aged 9–15 years were studied. Height and weight were measured; biological maturation was estimated with the maturity offset technique; MP measures included the 12 minute run (12MR), handgrip strength (HG), standing long jump (SLJ) and the shuttle run speed (SR) tests; physical activity (PA) was assessed using the Baecke questionnaire. A multiplicative allometric model was adopted to adjust for body size differences across countries. Reciprocal ponderal index (RPI) was found to be the most suitable body shape indicator associated with the 12MR, SLJ, HG and SR performance. A positive maturation offset parameter was also associated with a better performance in SLJ, HG and SR tests. Sex differences were found in all motor tests. Brazilian youth showed better scores in MP than their Peruvian peers, even when controlling for their body size differences The current study identified the key body size associated with four body mass-dependent MP tests. Biological maturation and PA were associated with strength and motor performance. Sex differences were found in all motor tests, as well as across countries favoring Brazilian children even when accounting for their body size/shape differences. PMID:26939118
Silva, Simonete; Bustamante, Alcibíades; Nevill, Alan; Katzmarzyk, Peter T; Freitas, Duarte; Prista, António; Maia, José
2016-01-01
Children from developed and developing countries differ in their body size and shape due to marked differences across their life history caused by social, economic and cultural differences which are also linked to their motor performance (MP). We used allometric models to identify size/shape characteristics associated with MP tests between Brazilian and Peruvian schoolchildren. A total of 4,560 subjects, 2,385 girls and 2,175 boys aged 9-15 years were studied. Height and weight were measured; biological maturation was estimated with the maturity offset technique; MP measures included the 12 minute run (12MR), handgrip strength (HG), standing long jump (SLJ) and the shuttle run speed (SR) tests; physical activity (PA) was assessed using the Baecke questionnaire. A multiplicative allometric model was adopted to adjust for body size differences across countries. Reciprocal ponderal index (RPI) was found to be the most suitable body shape indicator associated with the 12MR, SLJ, HG and SR performance. A positive maturation offset parameter was also associated with a better performance in SLJ, HG and SR tests. Sex differences were found in all motor tests. Brazilian youth showed better scores in MP than their Peruvian peers, even when controlling for their body size differences The current study identified the key body size associated with four body mass-dependent MP tests. Biological maturation and PA were associated with strength and motor performance. Sex differences were found in all motor tests, as well as across countries favoring Brazilian children even when accounting for their body size/shape differences.
Nangmenyi, Gordon; Yue, Zhongren; Mehrabi, Sharifeh; Mintz, Eric; Economy, James
2009-12-09
A number of researchers have deployed silver (Ag) nanoparticles through a number of techniques on various substrates including carbon, zeolites and polymers for water disinfection applications. However, Ag impregnated on an inorganic fiberglass surface through a simple electroless process was only recently reported for the first time. Fiberglass impregnated with Ag nanoparticles displays superior performance over carbon-based silver support systems but little is known about the factors that affect the architecture of the system, its interfacial properties and its consequent bactericidal activity. In this study, Ag content and particle size on a fiberglass substrate were manipulated by adjusting the AgNO(3) concentration, immersion time, temperature, solution pH and reduction temperature. The reduction chemistry of the Ag-nanoparticle-impregnated fiberglass is described and supported with thermal gravimetric analysis (TGA) and photoelectron spectroscopy (XPS) measurements. The Ag content along with the particle size and particle size distribution were characterized with scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy dispersive x-ray spectroscopy (EDS) and x-ray diffraction (XRD). The Ag content on the fiberglass mats ranged from 0.04 to 4.7 wt% Ag/g-fiber with a size distribution of 10-900 nm under standard processing conditions. Inductively coupled plasma mass spectrometry (ICP-MS) was used to analyze the Ag desorption from the fiberglass substrate, while the bactericidal properties were evaluated against Escherichia coli (E. coli).
NASA Astrophysics Data System (ADS)
Nangmenyi, Gordon; Yue, Zhongren; Mehrabi, Sharifeh; Mintz, Eric; Economy, James
2009-12-01
A number of researchers have deployed silver (Ag) nanoparticles through a number of techniques on various substrates including carbon, zeolites and polymers for water disinfection applications. However, Ag impregnated on an inorganic fiberglass surface through a simple electroless process was only recently reported for the first time. Fiberglass impregnated with Ag nanoparticles displays superior performance over carbon-based silver support systems but little is known about the factors that affect the architecture of the system, its interfacial properties and its consequent bactericidal activity. In this study, Ag content and particle size on a fiberglass substrate were manipulated by adjusting the AgNO3 concentration, immersion time, temperature, solution pH and reduction temperature. The reduction chemistry of the Ag-nanoparticle-impregnated fiberglass is described and supported with thermal gravimetric analysis (TGA) and photoelectron spectroscopy (XPS) measurements. The Ag content along with the particle size and particle size distribution were characterized with scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy dispersive x-ray spectroscopy (EDS) and x-ray diffraction (XRD). The Ag content on the fiberglass mats ranged from 0.04 to 4.7 wt% Ag/g-fiber with a size distribution of 10-900 nm under standard processing conditions. Inductively coupled plasma mass spectrometry (ICP-MS) was used to analyze the Ag desorption from the fiberglass substrate, while the bactericidal properties were evaluated against Escherichia coli (E. coli).
Social network analysis of public health programs to measure partnership.
Schoen, Martin W; Moreland-Russell, Sarah; Prewitt, Kim; Carothers, Bobbi J
2014-12-01
In order to prevent chronic diseases, community-based programs are encouraged to take an ecological approach to public health promotion and involve many diverse partners. Little is known about measuring partnership in implementing public health strategies. We collected data from 23 Missouri communities in early 2012 that received funding from three separate programs to prevent obesity and/or reduce tobacco use. While all of these funding programs encourage partnership, only the Social Innovation for Missouri (SIM) program included a focus on building community capacity and enhancing collaboration. Social network analysis techniques were used to understand contact and collaboration networks in community organizations. Measurements of average degree, density, degree centralization, and betweenness centralization were calculated for each network. Because of the various sizes of the networks, we conducted comparative analyses with and without adjustment for network size. SIM programs had increased measurements of average degree for partner collaboration and larger networks. When controlling for network size, SIM groups had higher measures of network density and lower measures of degree centralization and betweenness centralization. SIM collaboration networks were more dense and less centralized, indicating increased partnership. The methods described in this paper can be used to compare partnership in community networks of various sizes. Further research is necessary to define causal mechanisms of partnership development and their relationship to public health outcomes. Copyright © 2014 Elsevier Ltd. All rights reserved.
Guo, Shuang; Qiu, Bai-Ling; Zhu, Chen-Qi; Yang, Ya-Ya Gao; Wu, Di; Liang, Qi-Hui; Han, Nan-Yin
2016-09-15
Gravitational field-flow fractionation (GrFFF) is a useful technique for separation and characterization for micrometer-sized particles. Elution behavior of micrometer-sized particles in GrFFF was researched in this study. Particles in GrFFF channel are subject to hydrodynamic lift forces (HLF), fluid inertial forces and gravity, which drive them to different velocities by carrier flow, resulting in a size-based separation. Effects of ionic strength, flow rate and viscosity as well as methanol were investigated using polystyrene latex beads as model particles. This study is devoted to experimental verification of the effect of every factor and their comprehensive function. All experiments were performed to show isolated influence of every variable factor. The orthogonal design test was used to evaluate various factors comprehensively. Results suggested that retention ratio of particles increases with increasing flow rate or the viscosity of carrier liquid by adjusting external forces acting on particles. In addition, retention ratio increases as ionic strength decreases because of decreased electrostatic repulsion between particles and channel accumulation wall. As far as methanol, there is no general trend due to the change of both density and viscosity. On the basis of orthogonal design test it was found that viscosity of carrier liquid plays a significant role in determining resolution of micrometer-sized particles in GrFFF. Copyright © 2016 Elsevier B.V. All rights reserved.
Enhanced centrifuge-based approach to powder characterization
NASA Astrophysics Data System (ADS)
Thomas, Myles Calvin
Many types of manufacturing processes involve powders and are affected by powder behavior. It is highly desirable to implement tools that allow the behavior of bulk powder to be predicted based on the behavior of only small quantities of powder. Such descriptions can enable engineers to significantly improve the performance of powder processing and formulation steps. In this work, an enhancement of the centrifuge technique is proposed as a means of powder characterization. This enhanced method uses specially designed substrates with hemispherical indentations within the centrifuge. The method was tested using simulations of the momentum balance at the substrate surface. Initial simulations were performed with an ideal powder containing smooth, spherical particles distributed on substrates designed with indentations. The van der Waals adhesion between the powder, whose size distribution was based on an experimentally-determined distribution from a commercial silica powder, and the indentations was calculated and compared to the removal force created in the centrifuge. This provided a way to relate the powder size distribution to the rotational speed required for particle removal for various indentation sizes. Due to the distinct form of the data from these simulations, the cumulative size distribution of the powder and the Hamaker constant for the system were be extracted. After establishing adhesion force characterization for an ideal powder, the same proof-of-concept procedure was followed for a more realistic system with a simulated rough powder modeled as spheres with sinusoidal protrusions and intrusions around the surface. From these simulations, it was discovered that an equivalent powder of smooth spherical particles could be used to describe the adhesion behavior of the rough spherical powder by establishing a size-dependent 'effective' Hamaker constant distribution. This development made it possible to describe the surface roughness effects of the entire powder through one adjustable parameter that was linked to the size distribution. It is important to note that when the engineered substrates (hemispherical indentations) were applied, it was possible to extract both powder size distribution and effective Hamaker constant information from the simulated centrifuge adhesion experiments. Experimental validation of the simulated technique was performed with a silica powder dispersed onto a stainless steel substrate with no engineered surface features. Though the proof-of-concept work was accomplished for indented substrates, non-ideal, relatively flat (non-indented) substrates were used experimentally to demonstrate that the technique can be extended to this case. The experimental data was then used within the newly developed simulation procedure to show its application to real systems. In the absence of engineered features on the substrates, it was necessary to specify the size distribution of the powder as an input to the simulator. With this information, it was possible to extract an effective Hamaker constant distribution and when the effective Hamaker constant distribution was applied in conjunction with the size distribution, the observed adhesion force distribution was described precisely. An equation was developed that related the normalized effective Hamaker constants (normalized by the particle diameter) to the particle diameter was formulated from the effective Hamaker constant distribution. It was shown, by application of the equation, that the adhesion behavior of an ideal (smooth, spherical) powder with an experimentally-validated, effective Hamaker constant distribution could be used to effectively represent that of a realistic powder. Thus, the roughness effects and size variations of a real powder are captured in this one distributed parameter (effective Hamaker constant distribution) which provides a substantial improvement to the existing technique. This can lead to better optimization of powder processing by enhancing powder behavior models.
Candel, Math J J M; Van Breukelen, Gerard J P
2010-06-30
Adjustments of sample size formulas are given for varying cluster sizes in cluster randomized trials with a binary outcome when testing the treatment effect with mixed effects logistic regression using second-order penalized quasi-likelihood estimation (PQL). Starting from first-order marginal quasi-likelihood (MQL) estimation of the treatment effect, the asymptotic relative efficiency of unequal versus equal cluster sizes is derived. A Monte Carlo simulation study shows this asymptotic relative efficiency to be rather accurate for realistic sample sizes, when employing second-order PQL. An approximate, simpler formula is presented to estimate the efficiency loss due to varying cluster sizes when planning a trial. In many cases sampling 14 per cent more clusters is sufficient to repair the efficiency loss due to varying cluster sizes. Since current closed-form formulas for sample size calculation are based on first-order MQL, planning a trial also requires a conversion factor to obtain the variance of the second-order PQL estimator. In a second Monte Carlo study, this conversion factor turned out to be 1.25 at most. (c) 2010 John Wiley & Sons, Ltd.
Shin, Kwang Cheol; Park, Seung Bo; Jo, Geun Sik
2009-01-01
In the fields of production, manufacturing and supply chain management, Radio Frequency Identification (RFID) is regarded as one of the most important technologies. Nowadays, Mobile RFID, which is often installed in carts or forklift trucks, is increasingly being applied to the search for and checkout of items in warehouses, supermarkets, libraries and other industrial fields. In using Mobile RFID, since the readers are continuously moving, they can interfere with each other when they attempt to read the tags. In this study, we suggest a Time Division Multiple Access (TDMA) based anti-collision algorithm for Mobile RFID readers. Our algorithm automatically adjusts the frame size of each reader without using manual parameters by adopting the dynamic frame size adjustment strategy when collisions occur at a reader. Through experiments on a simulated environment for Mobile RFID readers, we show that the proposed method improves the number of successful transmissions by about 228% on average, compared with Colorwave, a representative TDMA based anti-collision algorithm. PMID:22399942
Shin, Kwang Cheol; Park, Seung Bo; Jo, Geun Sik
2009-01-01
In the fields of production, manufacturing and supply chain management, Radio Frequency Identification (RFID) is regarded as one of the most important technologies. Nowadays, Mobile RFID, which is often installed in carts or forklift trucks, is increasingly being applied to the search for and checkout of items in warehouses, supermarkets, libraries and other industrial fields. In using Mobile RFID, since the readers are continuously moving, they can interfere with each other when they attempt to read the tags. In this study, we suggest a Time Division Multiple Access (TDMA) based anti-collision algorithm for Mobile RFID readers. Our algorithm automatically adjusts the frame size of each reader without using manual parameters by adopting the dynamic frame size adjustment strategy when collisions occur at a reader. Through experiments on a simulated environment for Mobile RFID readers, we show that the proposed method improves the number of successful transmissions by about 228% on average, compared with Colorwave, a representative TDMA based anti-collision algorithm.
Modified fluoroscopy-guided sacroiliac joint injection: a technical report.
Liliang, Po-Chou; Liang, Cheng-Loong; Lu, Kang; Weng, Hui-Ching; Syu, Fei-Kai
2014-09-01
Sacroiliac joint (SIJ) injection can occasionally be challenging. We describe our experience in using conventional technique, and we developed an adjustment to overcome difficulties incurred. Conventional technique required superimposition of the posterior and anterior SIJ lines. If this technique failed to provide entry into the joint, fluoroscopy was slightly adjusted to obtain an oblique view. Of 50 SIJ injections, 29 (58%; 44-72%) were successfully performed using conventional technique. In another 21 procedures, 18 (85.7%; 64-99%) were subsequently completed using oblique view technique. The medial joint line, viewed from this angle, corresponded to the posterior joint line in 17 cases. The lateral joint line corresponded to the posterior joint line in one case. Oblique view technique can improve the success rate of SIJ injection. Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Emerson, Sean Christian
The effect of acoustic and hydrodynamic cavitation on the precipitation of inorganic catalytic materials, specifically titania supported gold, was investigated. The overall objective was to understand the fundamental factors involved in synthesizing nanometer-size catalytic materials in the 1--10 nm range in a cavitating field. Materials with grain sizes in this range have been associated with enhanced catalytic activity compared to larger grain size materials. A new chemical approach was used to produce titania supported gold by co-precipitation with higher gold yields compared to other synthesis methods. Using this approach, it was determined that acoustic cavitation was unable to influence the gold mean crystallite size compared to non-sonicated catalysts. However, gold concentration on the catalysts was found to be very important for CO oxidation activity. By decreasing the gold concentration from a weight loading of 0.50% down to approximately 0.05%, the rate of reaction per mole of gold was found to increase by a factor of 19. Hydrodynamic cavitation at low pressures (6.9--48 bar) was determined to have no effect on gold crystallite size at a fixed gold content for the same precipitation technique used in the acoustic cavitation studies. By changing the chemistry of the precipitation system, however, it was found that a synergy existed between the dilution of the gold precursor solution, the orifice diameter, and the reducing agent addition rate. Individually, these factors were found to have little effect and only their interaction allowed gold grain size control in the range of 8--80 nm. Further modification of the system chemistry and the use of hydrodynamic cavitation at pressures in excess of 690 bar allowed the systematic control of gold crystallite size in the range of 2--9 nm for catalysts containing 2.27 +/- 0.17% gold. In addition, it was shown that the enhanced mixing due to cavitation led to larger gold yields compared to classical syntheses. The control of gold grain size was gained at the loss of CO activity, which was attributed to the formation of non-removable sodium titanate species. The increased mixing associated with cavitation contributed to the activity loss by partially burying the gold and incorporating more of the sodium titanate species into the catalysts. This work produced the first evidence of hydrodynamic cavitation influencing the gold crystallite size on titania supported gold catalysts and is the only study reporting the control of grain size by simple mechanical adjustment of the experimental parameters. Despite the low activity observed due to sodium titanate, the methodology of adjusting the chemistry of a precipitating system could be used to eliminate such species. The approach of modifying the chemical precipitation kinetics relative to the dynamics of cavitation offers a general scheme for future research on cavitational processing effects.
Electrophoretic deposition of fluorescent Cu and Au sheets for light-emitting diodes
NASA Astrophysics Data System (ADS)
Liu, Jiale; Wu, Zhennan; Li, Tingting; Zhou, Ding; Zhang, Kai; Sheng, Yu; Cui, Jianli; Zhang, Hao; Yang, Bai
2015-12-01
Electrophoretic deposition (EPD) is a conventional method for fabricating film materials from nanometer-sized building blocks, and exhibits the advantages of low-cost, high-efficiency, wide-range thickness adjustment, and uniform deposition. Inspired by the interest in the application of two-dimensional (2D) nanomaterials, the EPD technique has been recently extended to building blocks with 2D features. However, the studies are mainly focused on simplex building blocks. The utilization of multiplex building blocks is rarely reported. In this work, we demonstrate a controlled EPD of Cu and Au sheets, which are 2D assemblies of luminescent Cu and Au nanoclusters. Systematic investigations reveal that both the deposition efficiency and the thickness are determined by the lateral size of the sheets. For Cu sheets with a large lateral size, a high ζ-potential and strong face-to-face van der Waals interactions facilitate the deposition with high efficiency. However, for Au sheets, the small lateral size and ζ-potential limit the formation of a thick film. To solve this problem, the deposition dynamics are controlled by increasing the concentration of the Au sheets and adding acetone. This understanding permits the fabrication of a binary EPD film by the stepwise deposition of Cu and Au sheets, thus producing a luminescent film with both Cu green emission and Au red emission. A white light-emitting diode prototype with color coordinates (x, y) = (0.31, 0.36) is fabricated by employing the EPD film as a color conversion layer on a 365 nm GaN clip and further tuning the amount of deposited Cu and Au sheets.Electrophoretic deposition (EPD) is a conventional method for fabricating film materials from nanometer-sized building blocks, and exhibits the advantages of low-cost, high-efficiency, wide-range thickness adjustment, and uniform deposition. Inspired by the interest in the application of two-dimensional (2D) nanomaterials, the EPD technique has been recently extended to building blocks with 2D features. However, the studies are mainly focused on simplex building blocks. The utilization of multiplex building blocks is rarely reported. In this work, we demonstrate a controlled EPD of Cu and Au sheets, which are 2D assemblies of luminescent Cu and Au nanoclusters. Systematic investigations reveal that both the deposition efficiency and the thickness are determined by the lateral size of the sheets. For Cu sheets with a large lateral size, a high ζ-potential and strong face-to-face van der Waals interactions facilitate the deposition with high efficiency. However, for Au sheets, the small lateral size and ζ-potential limit the formation of a thick film. To solve this problem, the deposition dynamics are controlled by increasing the concentration of the Au sheets and adding acetone. This understanding permits the fabrication of a binary EPD film by the stepwise deposition of Cu and Au sheets, thus producing a luminescent film with both Cu green emission and Au red emission. A white light-emitting diode prototype with color coordinates (x, y) = (0.31, 0.36) is fabricated by employing the EPD film as a color conversion layer on a 365 nm GaN clip and further tuning the amount of deposited Cu and Au sheets. Electronic supplementary information (ESI) available: Additional experimental information, and SEM images of Cu EPD films. See DOI: 10.1039/c5nr06599b
50 CFR 697.25 - Adjustment to management measures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... escape vent size, decreases in the lobster trap size, closed areas, closed seasons, landing limits, trip... equivalency for American lobster that are formally submitted to him/her in writing by the ASMFC. These...
50 CFR 697.25 - Adjustment to management measures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... escape vent size, decreases in the lobster trap size, closed areas, closed seasons, landing limits, trip... equivalency for American lobster that are formally submitted to him/her in writing by the ASMFC. These...
Does size matter? Kidney transplant donor size determines kidney function among living donors
Narasimhamurthy, Meenakshi; Smith, Lachlan M.; Machan, Jason T.; Reinert, Steven E.; Gohh, Reginald Y.; Dworkin, Lance D.; Merhi, Basma; Patel, Nikunjkumar; Beland, Michael D.
2017-01-01
Background Kidney donor outcomes are gaining attention, particularly as donor eligibility criteria continue to expand. Kidney size, a useful predictor of recipient kidney function, also likely correlates with donor outcomes. Although donor evaluation includes donor kidney size measurements, the association between kidney size and outcomes are poorly defined. Methods We examined the relationship between kidney size (body surface area-adjusted total volume, cortical volume and length) and renal outcomes (post-operative recovery and longer-term kidney function) among 85 kidney donors using general linear models and time-to-chronic kidney disease data. Results Donors with the largest adjusted cortical volume were more likely to achieve an estimated glomerular filtration rate (eGFR) ≥60 mL/min/1.73 m2 over a median 24-month follow-up than those with smaller cortical volumes (P <0.001), had a shorter duration of renal recovery (1.3–2.2 versus 32.5 days) and started with a higher eGFR at pre-donation (107–110 versus 91 mL/min/1.73 m2) and immediately post-nephrectomy (∼63 versus 50–51 mL/min/1.73 m2). Similar findings were seen with adjusted total volume and length. Conclusions Larger kidney donors were more likely to achieve an eGFR ≥60 mL/min/1.73 m2 with renal recovery over a shorter duration due to higher pre-donation and initial post-nephrectomy eGFRs. PMID:28638611
Choice of the Metric for Effect Size in Meta-analysis.
ERIC Educational Resources Information Center
McGaw, Barry; Glass, Gene V.
1980-01-01
There are difficulties in expressing effect sizes on a common metric when some studies use transformed scales to express group differences, or use factorial designs or covariance adjustments to obtain a reduced error term. A common metric on which effect sizes may be standardized is described. (Author/RL)
A short note on calculating the adjusted SAR index
USDA-ARS?s Scientific Manuscript database
A simple algebraic technique is presented for computing the adjusted SAR Index proposed by Suarez (1981). The statistical formula presented in this note facilitates the computation of the adjusted SAR without the use of either a look-up table, custom computer software or the need to compute exact a...
Dewland, Thomas A; Bibbins-Domingo, Kirsten; Lin, Feng; Vittinghoff, Eric; Foster, Elyse; Ogunyankin, Kofo O; Lima, Joao A; Jacobs, David R; Hu, Donglei; Burchard, Esteban G; Marcus, Gregory M
2016-01-01
Whites have an increased risk of atrial fibrillation (AF) compared to Blacks. The mechanism underlying this association is unknown. Left atrial (LA) size is an important AF risk factor, and studies in older adults suggest Whites have larger LA diameters. However, because AF itself causes LA dilation, LA size differences may be due to greater subclinical AF among older Whites. We therefore assessed for racial differences in LA size among young adults at low AF risk. The Coronary Artery Risk Development in Young Adults (CARDIA) study enrolled White and Black participants between 18 and 30 years of age. LA diameter was measured in a subset of participants using echocardiography at Year 5 (n = 4,201) and Year 25 (n = 3,373) of follow up. LA volume was also assessed at Year 5 (n = 2,489). Multivariate linear regression models were used to determine the adjusted association between race and LA size. In unadjusted analyses, mean LA diameter was significantly larger among Blacks compared to Whites both at Year 5 (35.5 ± 4.8 mm versus 35.1 ± 4.5 mm, p = 0.01) and Year 25 (37.4 ± 5.1 mm versus 36.8 ± 4.9 mm, p = 0.002). After adjusting for demographics, comorbidities, and echocardiographic parameters, Whites demonstrated an increased LA diameter (0.7 mm larger at Year 5, 95% CI 0.3-1.1, p<0.001; 0.6 mm larger at Year 25, 95% CI 0.3-1.0, p<0.001). There was no significant association between race and adjusted Year 5 LA volume. In conclusion, in a young, well-characterized cohort, the larger adjusted LA diameter among White participants suggests inherent differences in atrial structure may partially explain the higher risk of AF in Whites. The incongruent associations between race, LA diameter, and LA volume suggest that LA geometry, rather than size alone, may have implications for AF risk.
NASA Astrophysics Data System (ADS)
Sahlu, Dejene; Moges, Semu; Anagnostou, Emmanouil; Nikolopoulos, Efthymios; Hailu, Dereje; Mei, Yiwen
2017-04-01
Water resources assessment, planning and management in Africa is often constrained by the lack of reliable spatio-temporal rainfall data. Satellite products are steadily growing and offering useful alternative datasets of rainfall globally. The aim of this paper is to examine the error characteristics of the main available global satellite precipitation products with the view of improving the reliability of wet season (June to September) and small rainy season rainfall datasets over the Upper Blue Nile Basin. The study utilized six satellite derived precipitation datasets at 0.25-deg spatial grid size and daily temporal resolution:1) the near real-time (3B42_RT) and gauge adjusted (3B42_V7) products of Tropical Rainfall Measuring Mission (TRMM) Multi-satellite Precipitation Analysis (TMPA), 2) gauge adjusted and unadjusted Precipitation Estimation from Remotely Sensed Information using Artificial Neural Networks (PERSIANN) products and 3) the gauge adjusted and un-adjusted product of the National Oceanic and Atmospheric Administration (NOAA) Climate Prediction Center Morphing technique (CMORPH) over the period of 2000 to 2013.The error analysis utilized statistical techniques using bias ratio (Bias), correlation coefficient (CC) and root-mean-square-error (RMSE). Mean relative error (MRE), CC and RMSE metrics are further examined for six categories of 10th, 25th, 50th, 75th, 90thand 95th percentile rainfall thresholds. The skill of the satellite estimates is evaluated using categorical error metrics of missed rainfall volume fraction (MRV), falsely detected rainfall volume fraction (FRV), probability of detection (POD) and False Alarm Ratio (FAR). Results showed that six satellite based rainfall products underestimated wet season (June to September) gauge precipitation, with the exception of non-adjusted PERSIANN that overestimated the initial part of the rainy season (March to May). During the wet season, adjusted CMORPH has relatively better bias ratio (89 %) followed by 3B42_V7 (88%), adjusted-PERSIANN (81%), and non-adjusted products have relatively lower bias ratio. The results from CC statistic range from 0.34 to 0.43 for the wet season with adjusted products having slightly higher values. The initial rainy season has relatively higher CC than the wet season. Results from the categorical error metrics showed that CMORPH products have higher POD (91%), which are better in avoiding detecting false rainfall events in the wet season. For the initial rainy season PERSIANN (<50%), TMPA and CMORPH products are nearly equivalent (63-67%). On the other hand, FAR is below 0.1% for all products while in the wet season is higher (10-25%). In terms of rainfall volume of missed and false detected rainfall, CMORPH exhibited lower MRV ( 4.5%) than the TMPA and PERSIANN products (11-19%.) in the wet season. MRV for the initial rainy season was 20% for TMPA and CMORPH products and above 30% for PERSIANN products. All products are nearly equivalent in the wet season in terms of FRV (< 0.2%). The magnitude of MRE increases with gauge rainfall threshold categories with 3B42-V7 and adjusted CMORPH having lower magnitude, showing that underestimation of rainfall increases with increasing rainfall magnitude. CC also decreases with gauge rainfall threshold categories with CMORPH products having slightly higher values. Overall, all satellite products underestimated (overestimated) lower (higher) quantiles quantiles. We have observed that among the six satellite rainfall products the adjusted CMORPH has relatively better potential to improve wet season rainfall estimate and 3B42-V7 that initial rainy season in the Upper Blue Nile Basin.
Fayed, Bahgat; Abood, Amira; El-Sayed, Hoda S; Hashem, Amal M; Mehanna, Nayra S H
2018-08-01
A novel synbiotic multiparticulate microparticle was produced in the current study to expand the synbiotic industrial applications. Initially, the inulin was fabricated into PLGA nanoparticles. After the inulin entrapment efficiency was boosted to reach 92.9 ± 8.4% by adjusting the formulation parameters, the developed particles were characterized by different techniques such as particle size analyzer, TEM, and TLC. The obtained data showed that the particle size was 115.8 ± 82.7 nm, the particles had smooth surface and round shape, and the fabrication procedure did not affect the integrity of the inulin. Later, the inulin loaded nanoparticles together with selected Bifidobacterium species were double coated with gum arabic and alginate. The maximum survivability of the encapsulated Bifidobacterium in the simulated gastric solution reached 88.29% of the initial population, which was significantly higher than the survivability of the free bacteria. Finally, the inulin release from the multiparticulate microparticles was studied and found to be sustained over three days. Copyright © 2018 Elsevier Ltd. All rights reserved.
An aerial survey method to estimate sea otter abundance
Bodkin, James L.; Udevitz, Mark S.; Garner, Gerald W.; Amstrup, Steven C.; Laake, Jeffrey L.; Manly, Bryan F.J.; McDonald, Lyman L.; Robertson, Donna G.
1999-01-01
Sea otters (Enhydra lutris) occur in shallow coastal habitats and can be highly visible on the sea surface. They generally rest in groups and their detection depends on factors that include sea conditions, viewing platform, observer technique and skill, distance, habitat and group size. While visible on the surface, they are difficult to see while diving and may dive in response to an approaching survey platform. We developed and tested an aerial survey method that uses intensive searches within portions of strip transects to adjust for availability and sightability biases. Correction factors are estimated independently for each survey and observer. In tests of our method using shore-based observers, we estimated detection probabilities of 0.52-0.72 in standard strip-transects and 0.96 in intensive searches. We used the survey method in Prince William Sound, Alaska to estimate a sea otter population size of 9,092 (SE = 1422). The new method represents an improvement over various aspects of previous methods, but additional development and testing will be required prior to its broad application.
EVA Suit R and D for Performance Optimization
NASA Technical Reports Server (NTRS)
Cowley, Matthew S.; Harvill, Lauren; Benson, Elizabeth; Rajulu, Sudhakar
2014-01-01
Designing a planetary suit is very complex and often requires difficult trade-offs between performance, cost, mass, and system complexity. To verify that new suit designs meet requirements, full prototypes must be built and tested with human subjects. However, numerous design iterations will occur before the hardware meets those requirements. Traditional draw-prototype-test paradigms for R&D are prohibitively expensive with today's shrinking Government budgets. Personnel at NASA are developing modern simulation techniques which focus on human-centric designs by creating virtual prototype simulations and fully adjustable physical prototypes of suit hardware. During the R&D design phase, these easily modifiable representations of an EVA suit's hard components will allow designers to think creatively and exhaust design possibilities before they build and test working prototypes with human subjects. It allows scientists to comprehensively benchmark current suit capabilities and limitations for existing suit sizes and sizes that do not exist. This is extremely advantageous and enables comprehensive design down-selections to be made early in the design process, enables the use of human performance as design criteria, and enables designs to target specific populations
Normalized Cut Algorithm for Automated Assignment of Protein Domains
NASA Technical Reports Server (NTRS)
Samanta, M. P.; Liang, S.; Zha, H.; Biegel, Bryan A. (Technical Monitor)
2002-01-01
We present a novel computational method for automatic assignment of protein domains from structural data. At the core of our algorithm lies a recently proposed clustering technique that has been very successful for image-partitioning applications. This grap.,l-theory based clustering method uses the notion of a normalized cut to partition. an undirected graph into its strongly-connected components. Computer implementation of our method tested on the standard comparison set of proteins from the literature shows a high success rate (84%), better than most existing alternative In addition, several other features of our algorithm, such as reliance on few adjustable parameters, linear run-time with respect to the size of the protein and reduced complexity compared to other graph-theory based algorithms, would make it an attractive tool for structural biologists.
Strategic growth decisions in helper cichlids.
Heg, Dik; Bender, Nicole; Hamilton, Ian
2004-01-01
Recently, it has been shown that group-living subordinate clownfish Amphiprion percula increase their growth rate after acquiring the dominant breeder male position in the group. Evidence was found for strategic growth adjustments of subordinate fishes depending on the threat of eviction, i.e. subordinates adjust their growth rates so they remain smaller than the dominant fish and thereby limit the threat of being expelled from the territory. However, it is impossible to exclude several alternative factors that potentially could have influenced the observed changes in growth, owing to the nature of that experiment (removing the second-ranking fish--the breeder male--caused the third-ranking fish to change sex to become breeder male and change rank). We studied strategic growth decisions in the group-living Lake Tanganyika cichlid Neolamprologus pulcher under controlled laboratory conditions with ad libitum food availability. First, we show that male breeders grow faster than subordinate male helpers of the same initial size and confirm that N. pulcher shows status-dependent growth. Second, we improved on the experimental design by not removing the dominant breeder male in the group; instead we replaced the breeder male with a new breeder male in a full factorial design and measured growth of the subordinate male helpers is a function of the size difference with the old and the new breeder male. As predicted, male helpers showed strategic growth adjustments, i.e. growing faster when the size difference with the breeder male is large. Strategic growth adjustments were less pronounced than status-dependent growth adjustments. PMID:15801617
Strategic growth decisions in helper cichlids.
Heg, Dik; Bender, Nicole; Hamilton, Ian
2004-12-07
Recently, it has been shown that group-living subordinate clownfish Amphiprion percula increase their growth rate after acquiring the dominant breeder male position in the group. Evidence was found for strategic growth adjustments of subordinate fishes depending on the threat of eviction, i.e. subordinates adjust their growth rates so they remain smaller than the dominant fish and thereby limit the threat of being expelled from the territory. However, it is impossible to exclude several alternative factors that potentially could have influenced the observed changes in growth, owing to the nature of that experiment (removing the second-ranking fish--the breeder male--caused the third-ranking fish to change sex to become breeder male and change rank). We studied strategic growth decisions in the group-living Lake Tanganyika cichlid Neolamprologus pulcher under controlled laboratory conditions with ad libitum food availability. First, we show that male breeders grow faster than subordinate male helpers of the same initial size and confirm that N. pulcher shows status-dependent growth. Second, we improved on the experimental design by not removing the dominant breeder male in the group; instead we replaced the breeder male with a new breeder male in a full factorial design and measured growth of the subordinate male helpers is a function of the size difference with the old and the new breeder male. As predicted, male helpers showed strategic growth adjustments, i.e. growing faster when the size difference with the breeder male is large. Strategic growth adjustments were less pronounced than status-dependent growth adjustments.
Controlled and tunable polymer particles' production using a single microfluidic device
NASA Astrophysics Data System (ADS)
Amoyav, Benzion; Benny, Ofra
2018-04-01
Microfluidics technology offers a new platform to control liquids under flow in small volumes. The advantage of using small-scale reactions for droplet generation along with the capacity to control the preparation parameters, making microfluidic chips an attractive technology for optimizing encapsulation formulations. However, one of the drawback in this methodology is the ability to obtain a wide range of droplet sizes, from sub-micron to microns using a single chip design. In fact, typically, droplet chips are used for micron-dimension particles, while nanoparticles' synthesis requires complex chips design (i.e., microreactors and staggered herringbone micromixer). Here, we introduce the development of a highly tunable and controlled encapsulation technique, using two polymer compositions, for generating particles ranging from microns to nano-size using the same simple single microfluidic chip design. Poly(lactic-co-glycolic acid) (PLGA 50:50) or PLGA/polyethylene glycol polymeric particles were prepared with focused-flow chip, yielding monodisperse particle batches. We show that by varying flow rate, solvent, surfactant and polymer composition, we were able to optimize particles' size and decrease polydispersity index, using simple chip designs with no further related adjustments or costs. Utilizing this platform, which offers tight tuning of particle properties, could offer an important tool for formulation development and can potentially pave the way towards a better precision nanomedicine.
A Secure and Efficient Scalable Secret Image Sharing Scheme with Flexible Shadow Sizes
Xie, Dong; Li, Lixiang; Peng, Haipeng; Yang, Yixian
2017-01-01
In a general (k, n) scalable secret image sharing (SSIS) scheme, the secret image is shared by n participants and any k or more than k participants have the ability to reconstruct it. The scalability means that the amount of information in the reconstructed image scales in proportion to the number of the participants. In most existing SSIS schemes, the size of each image shadow is relatively large and the dealer does not has a flexible control strategy to adjust it to meet the demand of differen applications. Besides, almost all existing SSIS schemes are not applicable under noise circumstances. To address these deficiencies, in this paper we present a novel SSIS scheme based on a brand-new technique, called compressed sensing, which has been widely used in many fields such as image processing, wireless communication and medical imaging. Our scheme has the property of flexibility, which means that the dealer can achieve a compromise between the size of each shadow and the quality of the reconstructed image. In addition, our scheme has many other advantages, including smooth scalability, noise-resilient capability, and high security. The experimental results and the comparison with similar works demonstrate the feasibility and superiority of our scheme. PMID:28072851
Ringham, Brandy M; Kreidler, Sarah M; Muller, Keith E; Glueck, Deborah H
2016-07-30
Multilevel and longitudinal studies are frequently subject to missing data. For example, biomarker studies for oral cancer may involve multiple assays for each participant. Assays may fail, resulting in missing data values that can be assumed to be missing completely at random. Catellier and Muller proposed a data analytic technique to account for data missing at random in multilevel and longitudinal studies. They suggested modifying the degrees of freedom for both the Hotelling-Lawley trace F statistic and its null case reference distribution. We propose parallel adjustments to approximate power for this multivariate test in studies with missing data. The power approximations use a modified non-central F statistic, which is a function of (i) the expected number of complete cases, (ii) the expected number of non-missing pairs of responses, or (iii) the trimmed sample size, which is the planned sample size reduced by the anticipated proportion of missing data. The accuracy of the method is assessed by comparing the theoretical results to the Monte Carlo simulated power for the Catellier and Muller multivariate test. Over all experimental conditions, the closest approximation to the empirical power of the Catellier and Muller multivariate test is obtained by adjusting power calculations with the expected number of complete cases. The utility of the method is demonstrated with a multivariate power analysis for a hypothetical oral cancer biomarkers study. We describe how to implement the method using standard, commercially available software products and give example code. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Orthodontics for the dog. Treatment methods.
Ross, D L
1986-09-01
This article considers the prevention of orthodontic problems, occlusal adjustments, simple tooth movements, rotational techniques, tipping problems, adjustment of crown height, descriptions of common orthodontic appliances, and problems associated with therapy.
Rain Rate and DSD Retrievals at Kwajalein Atoll
NASA Astrophysics Data System (ADS)
Wolff, David; Marks, David; Tokay, Ali
2010-05-01
The dual-polarization weather radar on Kwajalein Atoll in the Republic of the Marshall Islands (KPOL) is one of the only full-time (24/7) operational S-band dual-polarimetric (DP) radars in the tropics. Using the DP data from KPOL, as well as data from a Joss-Waldvogel disdrometer on Kwajalein Island, algorithms for quality control, as well as calibration of reflectivity and differential reflectivity have been developed and adapted for application in a near real-time operational environment. Observations during light rain and drizzle show that KPOL measurements (since 2006) meet or exceed quality thresholds for these applications (as determined by consensus of the radar community). While the methodology for development of such applications is well documented, tuning of specific algorithms to a particular regime and observed raindrop size distributions requires a comprehensive testing and adjustment period to ensure high quality products. Upon application of these data quality techniques to the KPOL data, we have tested and compared several different rain retrieval algorithms. These include conventional Z-R, DP hybrid techniques, as well as polarimetrically-tuned Z-R described by Bringi et al. 2004. One of the major benefits of the polarimetrically tuned Z-R technique, is its ability to use the DP observations to retrieve key parameters of the drop size distribution (DSD), such as the median drop diameter, and the intercept and shape parameter of the assumed gammaDSD. We will show several such retrievals for different rain systems, as well as their distribution with height below the melting layer. From a physical validation perspective, such DSD parameter retrievals provide an important means to cross-validate microphysical parameterizations in GPM Dual-frequency Precipitation Radar (DPR) and GPM Microwave Imager (GMI) retrieval algorithms.
Yu, Tzy-Chyi; Zhou, Huanxue
2015-09-01
Evaluate performance of techniques used to handle missing cost-to-charge ratio (CCR) data in the USA Healthcare Cost and Utilization Project's Nationwide Inpatient Sample. Four techniques to replace missing CCR data were evaluated: deleting discharges with missing CCRs (complete case analysis), reweighting as recommended by Healthcare Cost and Utilization Project, reweighting by adjustment cells and hot deck imputation by adjustment cells. Bias and root mean squared error of these techniques on hospital cost were evaluated in five disease cohorts. Similar mean cost estimates would be obtained with any of the four techniques when the percentage of missing data is low (<10%). When total cost is the outcome of interest, a reweighting technique to avoid underestimation from dropping observations with missing data should be adopted.
Paterson, K L; Sosdian, L; Hinman, R S; Wrigley, T V; Kasza, J; Dowsey, M; Choong, P; Bennell, K L
2017-11-01
Sex and body mass may influence knee biomechanics associated with poor total knee arthroplasty (TKA) outcomes for knee osteoarthritis (OA). This study aimed to determine if gait differed between men and women, and overweight and class I obese patients with severe knee OA awaiting TKA. 34 patients with severe knee OA (average age 70.0 (SD 7.2) years, body mass index 30.3 (4.1kg/m 2 )) were recruited from a TKA waiting list. Three-dimensional gait analysis was performed at self-selected walking speed. Comparisons were made between men and women, and overweight (body mass index (BMI) 25.0-29.9kg/m 2 ) and class I obese (BMI 30.0-34.9kg/m 2 ) participants. Biomechanical outcomes included absolute and body size-adjusted peak knee adduction moment (KAM), KAM impulse, peak knee flexion moment, as well as peak knee flexion and varus-valgus angles, peak varus-valgus thrust, and peak vertical ground reaction force (GRF). Men had a higher absolute peak KAM, KAM impulse and peak GRF compared to women, and this sex-difference in frontal plane moments remained after adjusting for body size. However, when additionally adjusting for static knee alignment, differences disappeared. Knee biomechanics were similar between obesity groups after adjusting for the greater body weight of those with class I obesity. Men had greater KAM and KAM impulse even after adjustment for body size; however adjustment for their more varus knees removed this difference. Obesity group did not influence knee joint kinematics or moments. This suggests sex- and obesity-differences in these variables may not be associated with TKA outcomes. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ghai, Babita; Sethi, Sameer; Ram, Jagat; Wig, Jyotsna
2013-02-01
Clinical end points are often used to guide inflation and adequacy of cuff seal after laryngeal mask airway placement. However, clinical end points for cuff inflation have been shown to have significantly higher intracuff pressure. The adjusted cuff pressure between 55 and 60 cm H(2)O causes significantly better seal of laryngeal mask airway. We prospectively assessed the cuff pressures generated by cuff inflation guided by clinical end points, and the actual volume of air required to achieve cuff pressures between 55 and 60 cm H(2)O for sizes 1-2.5 reusable classic laryngeal mask airway. Two hundred and three ASA I and II children undergoing elective cataract surgery requiring general anesthesia receiving laryngeal mask airway sizes 1-2.5 were recruited to this study. The laryngeal mask airway was placed using standard technique. After insertion of laryngeal mask airway, the cuff was slowly inflated until a slight outward shift of device was noted. Cuff pressures were measured using calibrated hand held Portex Cuff Inflator Pressure Gauge (Portex Limited, Hythe, Kent, UK). If the cuff pressure was >60 cm H(2)O, the cuff was deflated to achieve a cuff pressure of 55-60 cm H(2)O. The volume of air required to achieve this pressure was recorded. The volume of air required to achieve the pressure between 55 and 60 cm H(2)O in laryngeal mask airway size 1, 1.5, 2.0, and 2.5 were 2.750 ± 0.2565, 4.951 ± 0.5378, 6.927 ± 0.6328, and 10.208 ± 1.4535 ml, respectively. The difference between the initial and the final cuff volumes and pressures in all laryngeal mask airway sizes were statistically significant(P = 0.000). Lower cuff volumes are required to achieve a pressure of 60 cm H(2)O than those required if clinical end points are used as a sole guide for determining cuff inflation for patients receiving pediatric laryngeal mask airways. © 2012 Blackwell Publishing Ltd.
NASA Astrophysics Data System (ADS)
Zhu, Jing; Wang, Xingshu; Wang, Jun; Dai, Dongkai; Xiong, Hao
2016-10-01
Former studies have proved that the attitude error in a single-axis rotation INS/GPS integrated system tracks the high frequency component of the deflections of the vertical (DOV) with a fixed delay and tracking error. This paper analyses the influence of the nominal process noise covariance matrix Q on the tracking error as well as the response delay, and proposed a Q-adjusting technique to obtain the attitude error which can track the DOV better. Simulation results show that different settings of Q lead to different response delay and tracking error; there exists optimal Q which leads to a minimum tracking error and a comparatively short response delay; for systems with different accuracy, different Q-adjusting strategy should be adopted. In this way, the DOV estimation accuracy of using the attitude error as the observation can be improved. According to the simulation results, the DOV estimation accuracy after using the Q-adjusting technique is improved by approximate 23% and 33% respectively compared to that of the Earth Model EGM2008 and the direct attitude difference method.
NASA Astrophysics Data System (ADS)
Miller, Timothy M.; Abrahams, John H.; Allen, Christine A.
2006-04-01
We report a fabrication process for deep etching silicon to different depths with a single masking layer, using standard masking and exposure techniques. Using this technique, we have incorporated a deep notch in the support walls of a transition-edge-sensor (TES) bolometer array during the detector back-etch, while simultaneously creating a cavity behind the detector. The notches serve to receive the support beams of a separate component, the Backshort-Under-Grid (BUG), an array of adjustable height quarter-wave backshorts that fill the cavities behind each pixel in the detector array. The backshort spacing, set prior to securing to the detector array, can be controlled from 25 to 300 μm by adjusting only a few process steps. In addition to backshort spacing, the interlocking beams and notches provide positioning and structural support for the ˜1 mm pitch, 8×8 array. This process is being incorporated into developing a TES bolometer array with an adjustable backshort for use in far-infrared astronomy. The masking technique and machining process used to fabricate the interlocking walls will be discussed.
Adjustable speed drive study, part 1
NASA Astrophysics Data System (ADS)
Wallace, A.
1989-08-01
Advances in speed control for motors in recent years, notably those in power electronics, have widened the range of application for several adjustable speed drive (ASD) types to include the smaller horsepower sizes. The dc motor drive, formerly in almost universal use for speed control, is being challenged by the high efficiency induction motor/pulse width modulation (PWM) drive; and for special small horsepower size applications, by the permanent magnet motor/PWM inverter drive or by the switched reluctance motor drive. The main characteristics of the several ASD types suitable for small horsepower size applications are discussed, as well as their unwanted side effects: poor power factor, harmonic distortion of the supply, acoustic noise, and electromagnetic interference. A procedure is recommended for determining which, if any, ASD to use.
Hermetic Seal Leak Detection Apparatus with Variable Size Test Chamber
NASA Technical Reports Server (NTRS)
Kelley, Anthony R. (Inventor)
2015-01-01
The present invention is a versatile hermetic seal leak detection apparatus for testing hermetically sealed containers and devices for leaks without the need to create a custom or specially manufactured testing chamber conforming to the dimensions of the specific object under test. The size of the testing chamber may be mechanically adjusted by the novel use of bellows to reduce and optimize the amount of gas space in a test chamber which surrounds the hermetically sealed object under test. The present invention allows the size of the test chamber to be selectively adjusted during testing to provide an optimum test chamber gas space. The present invention may be further adapted to isolate and test specific portions of the hermetically sealed object under test for leaks.
Catheter-based time-gated near-infrared fluorescence/OCT imaging system
NASA Astrophysics Data System (ADS)
Lu, Yuankang; Abran, Maxime; Cloutier, Guy; Lesage, Frédéric
2018-02-01
We developed a new dual-modality intravascular imaging system based on fast time-gated fluorescence intensity imaging and spectral domain optical coherence tomography (SD-OCT) for the purpose of interventional detection of atherosclerosis. A pulsed supercontinuum laser was used for fluorescence and OCT imaging. A double-clad fiber (DCF)- based side-firing catheter was designed and fabricated to have a 23 μm spot size at a 2.2 mm working distance for OCT imaging. Its single-mode core is used for OCT, while its inner cladding transports fluorescence excitation light and collects fluorescent photons. The combination of OCT and fluorescence imaging was achieved by using a DCF coupler. For fluorescence detection, we used a time-gated technique with a novel single-photon avalanche diode (SPAD) working in an ultra-fast gating mode. A custom-made delay chip was integrated in the system to adjust the delay between the excitation laser pulse and the SPAD gate-ON window. This technique allowed to detect fluorescent photons of interest while rejecting most of the background photons, thus leading to a significantly improved signal to noise ratio (SNR). Experiments were carried out in turbid media mimicking tissue with an indocyanine green (ICG) inclusion (1 mM and 100 μM) to compare the time-gated technique and the conventional continuous detection technique. The gating technique increased twofold depth sensitivity, and tenfold SNR at large distances. The dual-modality imaging capacity of our system was also validated with a silicone-based tissue-mimicking phantom.
Variable flexure-based fluid filter
Brown, Steve B.; Colston, Jr., Billy W.; Marshall, Graham; Wolcott, Duane
2007-03-13
An apparatus and method for filtering particles from a fluid comprises a fluid inlet, a fluid outlet, a variable size passage between the fluid inlet and the fluid outlet, and means for adjusting the size of the variable size passage for filtering the particles from the fluid. An inlet fluid flow stream is introduced to a fixture with a variable size passage. The size of the variable size passage is set so that the fluid passes through the variable size passage but the particles do not pass through the variable size passage.
Method for producing ceramic particles and agglomerates
Phillips, Jonathan; Gleiman, Seth S.; Chen, Chun-Ku
2001-01-01
A method for generating spherical and irregularly shaped dense particles of ceramic oxides having a controlled particle size and particle size distribution. An aerosol containing precursor particles of oxide ceramics is directed into a plasma. As the particles flow through the hot zone of the plasma, they melt, collide, and join to form larger particles. If these larger particles remain in the hot zone, they continue melting and acquire a spherical shape that is retained after they exit the hot zone, cool down, and solidify. If they exit the hot zone before melting completely, their irregular shape persists and agglomerates are produced. The size and size distribution of the dense product particles can be controlled by adjusting several parameters, the most important in the case of powder precursors appears to be the density of powder in the aerosol stream that enters the plasma hot zone. This suggests that particle collision rate is responsible for determining ultimate size of the resulting sphere or agglomerate. Other parameters, particularly the gas flow rates and the microwave power, are also adjusted to control the particle size distribution.
Use of letter writing as a means of integrating an altered body image: a case study.
Rancour, Patricia; Brauer, Kathryn
2003-01-01
To describe the use of letter writing as a technique to assist patients in adjusting to an altered body image after dramatic cancer treatment. Published articles and books. Gestalt therapy, psychosynthesis, and journaling techniques evolve into a technique that can assist patients who are challenged to accept altered body parts. Described in a case study presentation, letter writing was found to assist female patients with recurrent breast cancer in adjusting to reconstruction of lost breasts. Nurses can use letter writing as a means of assisting patients through the grief process associated with body image alterations.
Detection and Sizing of Fatigue Cracks in Steel Welds with Advanced Eddy Current Techniques
NASA Astrophysics Data System (ADS)
Todorov, E. I.; Mohr, W. C.; Lozev, M. G.
2008-02-01
Butt-welded specimens were fatigued to produce cracks in the weld heat-affected zone. Advanced eddy current (AEC) techniques were used to detect and size the cracks through a coating. AEC results were compared with magnetic particle and phased-array ultrasonic techniques. Validation through destructive crack measurements was also conducted. Factors such as geometry, surface treatment, and crack tightness interfered with depth sizing. AEC inspection techniques have the potential of providing more accurate and complete sizing flaw data for manufacturing and in-service inspections.
Racial Differences in Home Dialysis Utilization and Outcomes in Canada.
Trinh, Emilie; Na, Yingbo; Sood, Manish M; Chan, Christopher T; Perl, Jeffrey
2017-11-07
Data on racial disparities in home dialysis utilization and outcomes are lacking in Canada, where health care is universally available. We studied patients starting maintenance dialysis between 1996 and 2012 in the Canadian Organ Replacement Register, stratified by race: white, Asian, black, Aboriginal, Indian subcontinent, and other. The association between race and treatment with home dialysis was examined using generalized linear models. Secondary outcomes assessed racial differences in all-cause mortality and technique failure using a Fine and Gray competing risk model. 66,600 patients initiated chronic dialysis between 1996 and 2012. Compared with whites ( n =46,092), treatment with home dialysis was lower among Aboriginals ( n =3866; adjusted relative risk, RR, 0.71; 95% confidence interval, CI, 0.66 to 0.76) and higher in Asians ( n =4157; adjusted RR, 1.28; 95% CI, 1.22 to 1.35) and others ( n =2170; adjusted RR, 1.12; 95% CI, 1.04 to 1.20) but similar in blacks ( n =2143) and subcontinent Indians ( n =2809). Black (adjusted hazard ratio, HR, 1.31; 95% CI, 1.16 to 1.48) and Aboriginal (adjusted HR, 1.19; 95% CI, 1.06 to 1.33) patients treated with peritoneal dialysis had a significantly higher adjusted risk of technique failure compared with whites, whereas Asians had a lower risk (adjusted HR, 0.89; 95% CI, 0.82 to 0.99). In patients on peritoneal dialysis, the risk of death was significantly lower in Asians (adjusted HR, 0.83; 95% CI, 0.75 to 0.92), blacks (adjusted HR, 0.71; 95% CI, 0.59 to 0.85), and others (adjusted HR, 0.79; 95% CI, 0.68 to 0.92) but higher in Aboriginals (adjusted HR, 1.16; 95% CI, 1.02 to 1.32) compared with whites. Among patients on home hemodialysis, no significant racial differences in patient and technique survival were observed, which may be limited by the low number of events among each subgroups. With the exception of Aboriginals, all racial minority groups in Canada were as likely to be treated with home dialysis compared with whites. However, significant racial differences exist in outcomes. Copyright © 2017 by the American Society of Nephrology.
Shafi, Nabil A; Singh, Gagan D; Smith, Thomas W; Rogers, Jason H
2018-05-01
To describe a novel balloon sizing technique used during adult transcatheter patent ductus arteriosus (PDA) closure. In addition, to determine the clinical and procedural outcomes in six patients who underwent PDA balloon sizing with subsequent deployment of a PDA occluder device. Transcatheter PDA closure in adults has excellent safety and procedural outcomes. However, PDA sizing in adults can be challenging due to variable defect size, high flow state, or anatomical complexity. We describe a series of six cases where the balloon- pull through technique was successfully performed for PDA sizing prior to transcatheter closure. Consecutive adult patients undergoing adult PDA closure at our institution were studied retrospectively. A partially inflated sizing balloon was pulled through the defect from the aorta into the pulmonary artery and the balloon waist diameter was measured. Procedural success and clinical outcomes were obtained. Six adult patients underwent successful balloon pull-through technique for PDA sizing during transcatheter PDA closure, since conventional angiography often gave suboptimal opacification of the defect. All PDAs were treated with closure devices based on balloon PDA sizing with complete closure and no complications. In three patients that underwent preprocedure computed tomography, the balloon size matched the CT derived measurements. The balloon pull-through technique for PDA sizing is a safe and accurate sizing modality in adults undergoing transcatheter PDA closure. © 2017 Wiley Periodicals, Inc.
Large active mirror in aluminium
NASA Astrophysics Data System (ADS)
Leblanc, Jean-M.; Rozelot, Jean-Pierre
1991-11-01
The Large Active Mirrors in Aluminum Project (LAMA) is intended as a metallic alternative to the conventional glass mirrors. This alternative is to bring about definite improvements in terms of lower cost, shorter manufacturing, and reduced brittleness. Combined in a system approach that integrates design, development, and manufacturing of both the aluminum meniscus and its active support, the LAMA project is a technologically consistent product for astronomical and laser telescopes. Large size mirrors can be delivered, up to 8 m diameter. Recent progress in active optics makes possible control, as well as real-time adjustment, of a metallic mirror's deformations, especially those induced by temperature variations and/or aging. It also enables correction of whatever low-frequency surface waves escaped polishing. Besides, the manufacturing process to produce the aluminum segments together with the electron welding technique ensure the material's homogeneity. Quality of the surface condition will result from optimized implementation of the specific aluminum machining and polishing techniques. This paper highlights the existing aluminum realizations compared to glass mirrors, and gives the main results obtained during a feasibility demonstration phase, based on 8 m mirror requirements.
Moreno-Vilet, Lorena; Bostyn, Stéphane; Flores-Montaño, Jose-Luis; Camacho-Ruiz, Rosa-María
2017-12-15
Agave fructans are increasingly important in food industry and nutrition sciences as a potential ingredient of functional food, thus practical analysis tools to characterize them are needed. In view of the importance of the molecular weight on the functional properties of agave fructans, this study has the purpose to optimize a method to determine their molecular weight distribution by HPLC-SEC for industrial application. The optimization was carried out using a simplex method. The optimum conditions obtained were at column temperature of 61.7°C using tri-distilled water without salt, adjusted pH of 5.4 and a flow rate of 0.36mL/min. The exclusion range is from 1 to 49 of polymerization degree (180-7966Da). This proposed method represents an accurate and fast alternative to standard methods involving multiple-detection or hydrolysis of fructans. The industrial applications of this technique might be for quality control, study of fractionation processes and determination of purity. Copyright © 2017 Elsevier Ltd. All rights reserved.
Kinetics of red blood cell rouleaux formation studied by light scattering.
Szolna-Chodór, Alicja; Bosek, Maciej; Grzegorzewski, Bronislaw
2015-02-01
Red blood cell (RBC) rouleaux formation was experimentally studied using a light scattering technique. The suspensions of RBCs were obtained from the blood of healthy donors. Hematocrit of the samples was adjusted ranging from 1% to 4%. Measurements of the intensity of the coherent component of light scattered by the suspensions were performed and the scattering coefficient of the suspensions was determined. The number of RBCs per rouleaux was obtained using anomalous diffraction theory. The technique was used to show the effect of time, hematocrit, and sample thickness on the process. The number of cells per rouleaux first increases linearly, reaches a critical value at ∼3 cells per rouleaux, and then a further increase in the rouleaux size is observed. The kinetic constant of the rouleaux growth in the linear region is found to be independent of hematocrit. The aggregation rate increases as the sample thickness increases. The time at which the critical region appears strongly decreases as the hematocrit of the suspension increases. © 2015 Society of Photo-Optical Instrumentation Engineers (SPIE)
NASA Astrophysics Data System (ADS)
Wada, Daichi; Igawa, Hirotaka; Tamayama, Masato; Kasai, Tokio; Arizono, Hitoshi; Murayama, Hideaki; Shiotsubo, Katsuya
2018-02-01
We have developed an optical fiber distributed sensing system based on optical frequency domain reflectometry (OFDR) that uses long-length fiber Bragg gratings (FBGs). This technique obtains strain data not as a point data from an FBG but as a distributed profile within the FBG. This system can measure the strain distribution profile with an adjustable high spatial resolution of the mm or sub-mm order in real-time. In this study, we applied this OFDR-FBG technique to a flying test bed that is a mid-sized jet passenger aircraft. We conducted flight tests and monitored the structural responses of a fuselage stringer and the bulkhead of the flying test bed during flights. The strain distribution variations were successfully monitored for various events including taxiing, takeoff, landing and several other maneuvers. The monitoring was effective not only for measuring the strain amplitude applied to the individual structural parts but also for understanding the characteristics of the structural responses in accordance with the flight maneuvers. We studied the correlations between various maneuvers and strains to explore the relationship between the operation and condition of aircraft.
Adaptive wall technology for minimization of wall interferences in transonic wind tunnels
NASA Technical Reports Server (NTRS)
Wolf, Stephen W. D.
1988-01-01
Modern experimental techniques to improve free air simulations in transonic wind tunnels by use of adaptive wall technology are reviewed. Considered are the significant advantages of adaptive wall testing techniques with respect to wall interferences, Reynolds number, tunnel drive power, and flow quality. The application of these testing techniques relies on making the test section boundaries adjustable and using a rapid wall adjustment procedure. A historical overview shows how the disjointed development of these testing techniques, since 1938, is closely linked to available computer support. An overview of Adaptive Wall Test Section (AWTS) designs shows a preference for use of relatively simple designs with solid adaptive walls in 2- and 3-D testing. Operational aspects of AWTS's are discussed with regard to production type operation where adaptive wall adjustments need to be quick. Both 2- and 3-D data are presented to illustrate the quality of AWTS data over the transonic speed range. Adaptive wall technology is available for general use in 2-D testing, even in cryogenic wind tunnels. In 3-D testing, more refinement of the adaptive wall testing techniques is required before more widespread use can be planned.
A Coherent VLSI Design Environment.
1986-03-31
Schema were a CMOS sorter and a TTL PC board for gathering statistics from a Multibus. Neither design was completed using Schema, but at least in the...technique for automatically adjusting signal delays in an MOS system has been developed. The Dynamic Delay Adjustment (DDA) technique provides...34Synchronization Reliability in CMOS Technology," IEEE J. of Solid - State Circuits, Vol. SC-20, No. 4, pp. 880-883, 1985. * [8] J. Hohl, W. Larsen and L. Schooley
A method of pre-surgical oral orthopaedics.
DiBiase, D D; Hunter, S B
1983-01-01
A preliminary report of a technique of pre-surgical treatment in cleft lip and palate patients is outlined utilizing an adjustable intra-oral appliance with extra-oral strapping. The appliance is constructed with an adjustable spring for expansion and two shelves overlapping in the midline to allow palatal continuity during treatment. Frequently, only one appliance for each patient is required. The techniques of appliance construction, pre-surgical management and surgical repair of the lip are outlined.
Mortimer, Duncan; Segal, Leonie
2008-01-01
Algorithms for converting descriptive measures of health status into quality-adjusted life year (QALY)--weights are now widely available, and their application in economic evaluation is increasingly commonplace. The objective of this study is to describe and compare existing conversion algorithms and to highlight issues bearing on the derivation and interpretation of the QALY-weights so obtained. Systematic review of algorithms for converting descriptive measures of health status into QALY-weights. The review identified a substantial body of literature comprising 46 derivation studies and 16 studies that provided evidence or commentary on the validity of conversion algorithms. Conversion algorithms were derived using 1 of 4 techniques: 1) transfer to utility regression, 2) response mapping, 3) effect size translation, and 4) "revaluing" outcome measures using preference-based scaling techniques. Although these techniques differ in their methodological/theoretical tradition, data requirements, and ease of derivation and application, the available evidence suggests that the sensitivity and validity of derived QALY-weights may be more dependent on the coverage and sensitivity of measures and the disease area/patient group under evaluation than on the technique used in derivation. Despite the recent proliferation of conversion algorithms, a number of questions bearing on the derivation and interpretation of derived QALY-weights remain unresolved. These unresolved issues suggest directions for future research in this area. In the meantime, analysts seeking guidance in selecting derived QALY-weights should consider the validity and feasibility of each conversion algorithm in the disease area and patient group under evaluation rather than restricting their choice to weights from a particular derivation technique.
Koltun, G.F.; Helsel, Dennis R.
1986-01-01
Identical stream-bottom material samples, when fractioned to the same size by different techniques, may contain significantly different trace-metal concentrations. Precision of techniques also may differ, which could affect the ability to discriminate between size-fractioned bottom-material samples having different metal concentrations. Bottom-material samples fractioned to less than 0.020 millimeters by means of three common techniques (air elutriation, sieving, and settling) were analyzed for six trace metals to determine whether the technique used to obtain the desired particle-size fraction affects the ability to discriminate between bottom materials having different trace-metal concentrations. In addition, this study attempts to assess whether median trace-metal concentrations in size-fractioned bottom materials of identical origin differ depending on the size-fractioning technique used. Finally, this study evaluates the efficiency of the three size-fractioning techniques in terms of time, expense, and effort involved. Bottom-material samples were collected at two sites in northeastern Ohio: One is located in an undeveloped forested basin, and the other is located in a basin having a mixture of industrial and surface-mining land uses. The sites were selected for their close physical proximity, similar contributing drainage areas, and the likelihood that trace-metal concentrations in the bottom materials would be significantly different. Statistically significant differences in the concentrations of trace metals were detected between bottom-material samples collected at the two sites when the samples had been size-fractioned by means of air elutriation or sieving. Statistical analyses of samples that had been size fractioned by settling in native water were not measurably different in any of the six trace metals analyzed. Results of multiple comparison tests suggest that differences related to size-fractioning technique were evident in median copper, lead, and iron concentrations. Technique-related differences in copper concentrations most likely resulted from contamination of air-elutriated samples by a feed tip on the elutriator apparatus. No technique-related differences were observed in chromium, manganese, or zinc concentrations. Although air elutriation was the most expensive sizefractioning technique investigated, samples fractioned by this technique appeared to provide a superior level of discrimination between metal concentrations present in the bottom materials of the two sites. Sieving was an adequate lower-cost but more laborintensive alternative.
Adjustment for reporting bias in network meta-analysis of antidepressant trials
2012-01-01
Background Network meta-analysis (NMA), a generalization of conventional MA, allows for assessing the relative effectiveness of multiple interventions. Reporting bias is a major threat to the validity of MA and NMA. Numerous methods are available to assess the robustness of MA results to reporting bias. We aimed to extend such methods to NMA. Methods We introduced 2 adjustment models for Bayesian NMA. First, we extended a meta-regression model that allows the effect size to depend on its standard error. Second, we used a selection model that estimates the propensity of trial results being published and in which trials with lower propensity are weighted up in the NMA model. Both models rely on the assumption that biases are exchangeable across the network. We applied the models to 2 networks of placebo-controlled trials of 12 antidepressants, with 74 trials in the US Food and Drug Administration (FDA) database but only 51 with published results. NMA and adjustment models were used to estimate the effects of the 12 drugs relative to placebo, the 66 effect sizes for all possible pair-wise comparisons between drugs, probabilities of being the best drug and ranking of drugs. We compared the results from the 2 adjustment models applied to published data and NMAs of published data and NMAs of FDA data, considered as representing the totality of the data. Results Both adjustment models showed reduced estimated effects for the 12 drugs relative to the placebo as compared with NMA of published data. Pair-wise effect sizes between drugs, probabilities of being the best drug and ranking of drugs were modified. Estimated drug effects relative to the placebo from both adjustment models were corrected (i.e., similar to those from NMA of FDA data) for some drugs but not others, which resulted in differences in pair-wise effect sizes between drugs and ranking. Conclusions In this case study, adjustment models showed that NMA of published data was not robust to reporting bias and provided estimates closer to that of NMA of FDA data, although not optimal. The validity of such methods depends on the number of trials in the network and the assumption that conventional MAs in the network share a common mean bias mechanism. PMID:23016799
Evolving Concepts on Adjusting Human Resting Energy Expenditure Measurements for Body Size
Heymsfield, Steven B.; Thomas, Diana; Bosy-Westphal, Anja; Shen, Wei; Peterson, Courtney M.; Müller, Manfred J.
2012-01-01
Establishing if an adult’s resting energy expenditure (REE) is high or low for their body size is a pervasive question in nutrition research. Early workers applied body mass and height as size measures and formulated the Surface Law and Kleiber’s Law, although each has limitations when adjusting REE. Body composition methods introduced during the mid-twentieth century provided a new opportunity to identify metabolically homogeneous “active” compartments. These compartments all show improved correlations with REE estimates over body mass-height approaches, but collectively share a common limitation: REE-body composition ratios are not “constant” but vary across men and women and with race, age, and body size. The now-accepted alternative to ratio-based norms is to adjust for predictors by applying regression models to calculate “residuals” that establish if a REE is relatively high or low. The distinguishing feature of statistical REE-body composition models is a “non-zero” intercept of unknown origin. The recent introduction of imaging methods has allowed development of physiological tissue-organ based REE prediction models. Herein we apply these imaging methods to provide a mechanistic explanation, supported by experimental data, for the non-zero intercept phenomenon and in that context propose future research directions for establishing between subject differences in relative energy metabolism. PMID:22863371
Strategies for Improving Power in School-Randomized Studies of Professional Development.
Kelcey, Ben; Phelps, Geoffrey
2013-12-01
Group-randomized designs are well suited for studies of professional development because they can accommodate programs that are delivered to intact groups (e.g., schools), the collaborative nature of professional development, and extant teacher/school assignments. Though group designs may be theoretically favorable, prior evidence has suggested that they may be challenging to conduct in professional development studies because well-powered designs will typically require large sample sizes or expect large effect sizes. Using teacher knowledge outcomes in mathematics, we investigated when and the extent to which there is evidence that covariance adjustment on a pretest, teacher certification, or demographic covariates can reduce the sample size necessary to achieve reasonable power. Our analyses drew on multilevel models and outcomes in five different content areas for over 4,000 teachers and 2,000 schools. Using these estimates, we assessed the minimum detectable effect sizes for several school-randomized designs with and without covariance adjustment. The analyses suggested that teachers' knowledge is substantially clustered within schools in each of the five content areas and that covariance adjustment for a pretest or, to a lesser extent, teacher certification, has the potential to transform designs that are unreasonably large for professional development studies into viable studies. © The Author(s) 2014.
Martena, Valentina; Shegokar, Ranjita; Di Martino, Piera; Müller, Rainer H
2014-09-01
Nicergoline, a poorly soluble active pharmaceutical ingredient, possesses vaso-active properties which causes peripheral and central vasodilatation. In this study, nanocrystals of nicergoline were prepared in an aqueous solution of polysorbate 80 (nanosuspension) by using four different laboratory scale size reduction techniques: high pressure homogenization (HPH), bead milling (BM) and combination techniques (high pressure homogenization followed by bead milling HPH + BM, and bead milling followed by high pressure homogenization BM + HPH). Nanocrystals were investigated regarding to their mean particles size, zeta potential and particle dissolution. A short term physical stability study on nanocrystals stored at three different temperatures (4, 20 and 40 °C) was performed to evaluate the tendency to change in particle size, aggregation and zeta potential. The size reduction technique and the process parameters like milling time, number of homogenization cycles and pressure greatly affected the size of nanocrystals. Among the techniques used, the combination techniques showed superior and consistent particle size reduction compared to the other two methods, HPH + BM and BM + HPH giving nanocrystals of a mean particle size of 260 and 353 nm, respectively. The particle dissolution was increased for any nanocrystals samples, but it was particularly increased by HPH and combination techniques. Independently to the production method, nicergoline nanocrystals showed slight increase in particle size over the time, but remained below 500 nm at 20 °C and refrigeration conditions.
The Large Introductory Class as an Exercise in Organization Design.
ERIC Educational Resources Information Center
Wagner, John A., III; Van Dyne, Linn
1999-01-01
Four methods for large group instruction differ in control and coordination dimensions: (1) centralization with mutual adjustment; (2) centralization with standardization; (3) decentralization with standardization; and (4) decentralization with mutual adjustment. Other factors to consider include class size and interests of various constituencies:…
Adjustable suture strabismus surgery in infants and children: a 19-year experience.
Kassem, Ahmed; Xue, Gilbert; Gandhi, Niral B; Tian, Jing; Guyton, David L
2018-06-01
To evaluate the success rate of adjustable suture techniques in horizontal eye muscle surgery in children ≤15 years of age over a 19-year period by a single surgeon. The medical records of all consecutive patients in this age group who underwent horizontal eye muscle surgery from 1989 through 2012 were reviewed retrospectively. Patients were divided into two groups: those in whom a nonadjustable suture technique was used and those in whom adjustable sutures were used. The following data were collected: type of strabismus, preoperative measurements, postoperative results, and reoperation rates. A total of 116 cases in the nonadjustable group and 521 cases in the adjustable group were included. In the adjustable group, adjustment was performed in 63% of the cases, because of either an under- (41%) or overcorrection (22%). The adjustment procedure was performed under topical proparacaine in 15% of cases and under intravenous propofol in 85%. For the adjustable group, 3-5 minutes more per muscle intraoperatively and 15-20 minutes for adjustment were required. No complications were encountered during the adjustment procedures. Early success rate, defined as alignment within 8 Δ of straight at 3 to 6 months' postoperative follow-up, was significantly greater in the adjustable group than in the nonadjustable group (77.7% vs 64.6% [P ≤ 0.03]). Of the adjustable patients, 15% required reoperation compared with 21% of the nonadjustable patients. Use of adjustable sutures in horizontal eye muscle surgery in children ≤15 years of age provided an improved success rate and fewer reoperations compared with nonadjustable sutures. Copyright © 2018 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.
EVALUATION OF A NEW MEAN SCALED AND MOMENT ADJUSTED TEST STATISTIC FOR SEM.
Tong, Xiaoxiao; Bentler, Peter M
2013-01-01
Recently a new mean scaled and skewness adjusted test statistic was developed for evaluating structural equation models in small samples and with potentially nonnormal data, but this statistic has received only limited evaluation. The performance of this statistic is compared to normal theory maximum likelihood and two well-known robust test statistics. A modification to the Satorra-Bentler scaled statistic is developed for the condition that sample size is smaller than degrees of freedom. The behavior of the four test statistics is evaluated with a Monte Carlo confirmatory factor analysis study that varies seven sample sizes and three distributional conditions obtained using Headrick's fifth-order transformation to nonnormality. The new statistic performs badly in most conditions except under the normal distribution. The goodness-of-fit χ(2) test based on maximum-likelihood estimation performed well under normal distributions as well as under a condition of asymptotic robustness. The Satorra-Bentler scaled test statistic performed best overall, while the mean scaled and variance adjusted test statistic outperformed the others at small and moderate sample sizes under certain distributional conditions.
NASA Astrophysics Data System (ADS)
Tan Shilan, Salihah; Amri Mazlan, Saiful; Ido, Yasushi; Hajalilou, Abdollah; Jeyadevan, Balachandran; Choi, Seung-Bok; Azhani Yunus, Nurul
2016-09-01
This work proposes different sizes of the plate-like particles from conventional spherical carbonyl iron (CI) particles by adjusting milling time in the ball mill process. The ball mill process to make the plate-like particles is called a solid-state powder processing technique which involves repeated welding, fracturing and re-welding of powder particles in a high-energy ball mill. The effect of ball milling process on the magnetic behavior of CI particles is firstly investigated by vibrating sample magnetometer. It is found form this investigation that the plate-like particles have higher saturation magnetization (about 8%) than that of the spherical particles. Subsequently, for the investigation on the sedimentation behavior the cylindrical measurement technique is used. It is observed from this measurement that the plate-like particles show slower sedimentation rate compared to the spherical particles indicating higher stability of the MR fluid. The field-dependent rheological properties of MR fluids based on the plate-like particles are then investigated with respect to the milling time which is directly connected to the size of the plate-like particles. In addition, the field-dependent rheological properties such as the yield stress are evaluated and compared between the plate-like particles based MR fluids and the spherical particles based MR fluid. It is found that the yield shear stress of the plate-like particles based MR fluid is increased up to 270% compared to the spherical particles based MR fluid.
Influence of apical enlargement on the repair of apical periodontitis in rats.
Jara, C M; Hartmann, R C; Böttcher, D E; Souza, T S; Gomes, M S; Figueiredo, J A P
2018-05-08
To evaluate the influence of different apical enlargement protocols on the radiographic and histological healing of apical periodontitis in rats. Apical periodontitis was induced bilaterally in the mandibular right and left first molars of 24 Wistar rats by pulp exposure to the oral cavity for 3 weeks. A standard serial root canal preparation technique was performed in the molar of one side, whilst the opposite side was the control group. Rats were randomly divided into three experimental groups (n = 8), according to the diameter of apical enlargement during root canal preparation: K-files size 20 (EG1), size 25 (EG2) and size 30 (EG3). Each animal was its own positive control, because the opposite arch remained untreated. Root canals were filled with a standard technique. After 3 weeks, the animals were euthanized. The main outcome of apical periodontitis healing was evaluated radiographically (mm 2 ) and histologically (ordinal scores of inflammation) using a HE staining technique. The measurement of effect was obtained between the three experimental groups by carrying out generalized estimating equations, with Poisson regression with robust variance, pairing each experimental group with its respective control group within animals, adjusted for the mean within animal differences, with α = 5%. The mean and standard deviations of radiographic apical periodontitis size (mm 2 ) and intensity of histological inflammatory scores were, respectively: EG1 (0.44 ± 0.27; 2.25 ± 0.46), EG2 (0.33 ± 0.10; 2.50 ± 0.53) and EG3 (0.22 ± 0.08; 2.63 ± 0.74). After 3 weeks, a significantly more favourable radiographic repair was observed when larger apical enlargement was performed (EG3), compared to EG1 and EG2 (P = 0.001). All experimental groups were associated with a significant difference on the radiographic and histological healing of apical periodontitis compared with its respective control group. Under the experimental conditions of this study, a larger apical enlargement protocol favoured a more rapid radiographic repair of apical periodontitis in rats after a 3-week follow-up. © 2018 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Adjusting for multiple prognostic factors in the analysis of randomised trials
2013-01-01
Background When multiple prognostic factors are adjusted for in the analysis of a randomised trial, it is unclear (1) whether it is necessary to account for each of the strata, formed by all combinations of the prognostic factors (stratified analysis), when randomisation has been balanced within each stratum (stratified randomisation), or whether adjusting for the main effects alone will suffice, and (2) the best method of adjustment in terms of type I error rate and power, irrespective of the randomisation method. Methods We used simulation to (1) determine if a stratified analysis is necessary after stratified randomisation, and (2) to compare different methods of adjustment in terms of power and type I error rate. We considered the following methods of analysis: adjusting for covariates in a regression model, adjusting for each stratum using either fixed or random effects, and Mantel-Haenszel or a stratified Cox model depending on outcome. Results Stratified analysis is required after stratified randomisation to maintain correct type I error rates when (a) there are strong interactions between prognostic factors, and (b) there are approximately equal number of patients in each stratum. However, simulations based on real trial data found that type I error rates were unaffected by the method of analysis (stratified vs unstratified), indicating these conditions were not met in real datasets. Comparison of different analysis methods found that with small sample sizes and a binary or time-to-event outcome, most analysis methods lead to either inflated type I error rates or a reduction in power; the lone exception was a stratified analysis using random effects for strata, which gave nominal type I error rates and adequate power. Conclusions It is unlikely that a stratified analysis is necessary after stratified randomisation except in extreme scenarios. Therefore, the method of analysis (accounting for the strata, or adjusting only for the covariates) will not generally need to depend on the method of randomisation used. Most methods of analysis work well with large sample sizes, however treating strata as random effects should be the analysis method of choice with binary or time-to-event outcomes and a small sample size. PMID:23898993
Heuch, Ingrid; Heuch, Ivar; Hagen, Knut; Zwart, John-Anker
2015-01-01
Previous work indicates that overweight and obese individuals carry an increased risk of experiencing chronic low back pain (LBP). It is not known, however, how the association with body size depends on the choice of anthropometric measure used. This work compares relationships with LBP for several measures of body size. Different results may indicate underlying mechanisms for the association between body size and risk of LBP. In a cohort study, baseline information was collected in the community-based HUNT2 (1995-1997) and HUNT3 (2006-2008) surveys in Norway. Participants were 10,059 women and 8725 men aged 30-69 years without LBP, and 3883 women and 2662 men with LBP at baseline. Associations with LBP at end of follow-up were assessed by generalized linear modeling, with adjustment for potential confounders. Relationships between waist-hip-ratio and occurrence of LBP at end of follow-up were weak and non-significant after adjustment for age, education, work status, physical activity, smoking, lipid levels and blood pressure. Positive associations with LBP at end of follow-up were all significant for body weight, BMI, waist circumference and hip circumference after similar adjustment, both in women without and with LBP at baseline, and in men without LBP at baseline. After additional mutual adjustment for anthropometric measures, the magnitude of the association with body weight increased in women without LBP at baseline (RR: 1.130 per standard deviation, 95% CI: 0.995-1.284) and in men (RR: 1.124, 95% CI 0.976-1.294), with other measures showing weak associations only. Central adiposity is unlikely to play a major role in the etiology of LBP. Total fat mass may be one common factor underlying the associations observed. The association with body weight remaining after mutual adjustment may reflect mechanical or structural components behind the relationship between overweight or obesity and LBP.
Adjusting Curvatures Of Large Mirrors And Lenses
NASA Technical Reports Server (NTRS)
Birnbaum, Morris M.
1992-01-01
Actuators apply stresses to generate distortions counteracting undesired distortions in technique for adjusting curvature of large focusing mirror or lens. Motor-and-gear assemblies under remote control vary squeeze of ring clamp and push or pull of hollow shaft to make fine adjustments in curvature of mirror. Applicable to large astronomical-telescope mirrors with diameters of 60 cm or more.
Technique of Axillary Use of a Combat Ready Clamp to Stop Junctional Bleeding
2013-01-01
compressed parallel to—but not on—the clavicle (Fig. 4). 5. Adjust the horizontal arm length by using its locking pin. 6. Adjust the vertical arm by...arm adjustment for square disk head contact atop the target. Fig. 4. Placing the square disk head atop the target, parallel to—but not on—the clavicle
Autonomous Aerial Refueling Ground Test Demonstration—A Sensor-in-the-Loop, Non-Tracking Method
Chen, Chao-I; Koseluk, Robert; Buchanan, Chase; Duerner, Andrew; Jeppesen, Brian; Laux, Hunter
2015-01-01
An essential capability for an unmanned aerial vehicle (UAV) to extend its airborne duration without increasing the size of the aircraft is called the autonomous aerial refueling (AAR). This paper proposes a sensor-in-the-loop, non-tracking method for probe-and-drogue style autonomous aerial refueling tasks by combining sensitivity adjustments of a 3D Flash LIDAR camera with computer vision based image-processing techniques. The method overcomes the inherit ambiguity issues when reconstructing 3D information from traditional 2D images by taking advantage of ready to use 3D point cloud data from the camera, followed by well-established computer vision techniques. These techniques include curve fitting algorithms and outlier removal with the random sample consensus (RANSAC) algorithm to reliably estimate the drogue center in 3D space, as well as to establish the relative position between the probe and the drogue. To demonstrate the feasibility of the proposed method on a real system, a ground navigation robot was designed and fabricated. Results presented in the paper show that using images acquired from a 3D Flash LIDAR camera as real time visual feedback, the ground robot is able to track a moving simulated drogue and continuously narrow the gap between the robot and the target autonomously. PMID:25970254
Cafri, Guy; Paxton, Elizabeth W; Love, Rebecca; Bini, Stefano A; Kurtz, Steven M
2017-05-01
The most common bearing surface used among primary THAs worldwide is a metal or ceramic femoral head that articulates against a highly crosslinked ultrahigh-molecular-weight polyethylene (HXLPE) acetabular liner. Despite their widespread use, relatively little is known about the comparative effectiveness of ceramic versus metal femoral heads with respect to risk of revision and dislocation as well as the role of head size in this relationship. The purpose of this study was to evaluate the risk of (1) all-cause revision in metal versus ceramic femoral heads when used with an HXLPE liner, including an evaluation of the effect of head size; and (2) dislocation in metal versus ceramic femoral heads when used with an HXLPE liner as well as an assessment of the effect of head size. Data were collected as part of the Kaiser Permanente Total Joint Replacement Registry between 2001 and 2013. Patients in this study were on average overweight (body mass index = 29 kg/m 2 ), 67 years old, mostly female (57%), and had osteoarthritis (93%) as the primary indication for surgery. The material of the femoral head (metal, ceramic) was crossed with head size (< 32, 32, 36, > 36 mm), yielding eight device groupings. Only uncemented devices were evaluated. The primary outcome was all-cause revision (n = 28,772) and the secondary outcome was dislocation within 1 year (n = 19,623). Propensity scores were used to adjust for potential confounding at the implant/patient level using between-within semiparametric survival models that control for surgeon and hospital confounding and adjust estimates for the within-cluster correlation among observations on the response. For all-cause revision, there was no difference between ceramic versus metal (reference) heads in combination with an HXLPE liner (hazard ratio [HR] = 0.82 [0.65-1.04], p = 0.099). Smaller metal head sizes of < 32 mm were associated with increased risk of revision relative to 36 mm (HR = 1.66 [1.20-2.31], p = 0.002, adjusted p = 0.025). For dislocation, ceramic heads increased risk relative to metal at < 32 mm only (HR = 4.39 [1.72-11.19], p = 0.002, adjusted p = 0.020). Head sizes < 32 mm were associated with increased risk of dislocation relative to 36 mm for metal (HR = 2.99 [1.40-6.39], p = 0.005, adjusted p = 0.047) and ceramic heads (HR = 15.69 [6.07-40.55], p < 0.001, adjusted p < 0.001). The results did not provide evidence for use of one femoral head material over another when used with HXLPE liners for the outcome of revision, but for dislocation, metal performed better than ceramic with < 32-mm heads. Overall, the findings suggest increased risk of revision/dislocation with head sizes < 32 mm. Level III, therapeutic study.
Jepsen, Karl J; Bigelow, Erin M R; Schlecht, Stephen H
2015-08-01
The twofold greater lifetime risk of fracturing a bone for white women compared with white men and black women has been attributed in part to differences in how the skeletal system accumulates bone mass during growth. On average, women build more slender long bones with less cortical area compared with men. Although slender bones are known to have a naturally lower cortical area compared with wider bones, it remains unclear whether the relatively lower cortical area of women is consistent with their increased slenderness or is reduced beyond that expected for the sex-specific differences in bone size and body size. Whether this sexual dimorphism is consistent with ethnic background and is recapitulated in the widely used mouse model also remains unclear. We asked (1) do black women build bones with reduced cortical area compared with black men; (2) do white women build bones with reduced cortical area compared with white men; and (3) do female mice build bones with reduced cortical area compared with male mice? Bone strength and cross-sectional morphology of adult human and mouse bone were calculated from quantitative CT images of the femoral midshaft. The data were tested for normality and regression analyses were used to test for differences in cortical area between men and women after adjusting for body size and bone size by general linear model (GLM). Linear regression analysis showed that the femurs of black women had 11% lower cortical area compared with those of black men after adjusting for body size and bone size (women: mean=357.7 mm2; 95% confidence interval [CI], 347.9-367.5 mm2; men: mean=400.1 mm2; 95% CI, 391.5-408.7 mm2; effect size=1.2; p<0.001, GLM). Likewise, the femurs of white women had 12% less cortical area compared with those of white men after adjusting for body size and bone size (women: mean=350.1 mm2; 95% CI, 340.4-359.8 mm2; men: mean=394.3 mm2; 95% CI, 386.5-402.1 mm2; effect size=1.3; p<0.001, GLM). In contrast, female and male femora from recombinant inbred mouse strains showed the opposite trend; femurs from female mice had a 4% larger cortical area compared with those of male mice after adjusting for body size and bone size (female: mean=0.73 mm2; 95% CI, 0.71-0.74 mm2; male: mean=0.70 mm2; 95% CI, 0.68-0.71 mm2; effect size=0.74; p=0.04, GLM). Female femurs are not simply a more slender version of male femurs. Women acquire substantially less mass (cortical area) for their body size and bone size compared with men. Our analysis questions whether mouse long bone is a suitable model to study human sexual dimorphism. Identifying differences in the way bones are constructed may be clinically important for developing sex-specific diagnostics and treatment strategies to reduce fragility fractures.
A framework for automatic feature extraction from airborne light detection and ranging data
NASA Astrophysics Data System (ADS)
Yan, Jianhua
Recent advances in airborne Light Detection and Ranging (LIDAR) technology allow rapid and inexpensive measurements of topography over large areas. Airborne LIDAR systems usually return a 3-dimensional cloud of point measurements from reflective objects scanned by the laser beneath the flight path. This technology is becoming a primary method for extracting information of different kinds of geometrical objects, such as high-resolution digital terrain models (DTMs), buildings and trees, etc. In the past decade, LIDAR gets more and more interest from researchers in the field of remote sensing and GIS. Compared to the traditional data sources, such as aerial photography and satellite images, LIDAR measurements are not influenced by sun shadow and relief displacement. However, voluminous data pose a new challenge for automated extraction the geometrical information from LIDAR measurements because many raster image processing techniques cannot be directly applied to irregularly spaced LIDAR points. In this dissertation, a framework is proposed to filter out information about different kinds of geometrical objects, such as terrain and buildings from LIDAR automatically. They are essential to numerous applications such as flood modeling, landslide prediction and hurricane animation. The framework consists of several intuitive algorithms. Firstly, a progressive morphological filter was developed to detect non-ground LIDAR measurements. By gradually increasing the window size and elevation difference threshold of the filter, the measurements of vehicles, vegetation, and buildings are removed, while ground data are preserved. Then, building measurements are identified from no-ground measurements using a region growing algorithm based on the plane-fitting technique. Raw footprints for segmented building measurements are derived by connecting boundary points and are further simplified and adjusted by several proposed operations to remove noise, which is caused by irregularly spaced LIDAR measurements. To reconstruct 3D building models, the raw 2D topology of each building is first extracted and then further adjusted. Since the adjusting operations for simple building models do not work well on 2D topology, 2D snake algorithm is proposed to adjust 2D topology. The 2D snake algorithm consists of newly defined energy functions for topology adjusting and a linear algorithm to find the minimal energy value of 2D snake problems. Data sets from urbanized areas including large institutional, commercial, and small residential buildings were employed to test the proposed framework. The results demonstrated that the proposed framework achieves a very good performance.
We report an eco-friendly synthesis of well–controlled, nano-to-micron-size, spherical SiO2 particles using non-hazardous solvent and a byproducts-producing system. It was found that the morphology and size of spherical SiO2 particles are controlled by adjusting the concentration...
77 FR 76839 - Home Mortgage Disclosure (Regulation C): Adjustment To Asset-Size Exemption Threshold
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-31
...The Bureau of Consumer Financial Protection (Bureau) is publishing a final rule amending the official commentary that interprets the requirements of the Bureau's Regulation C (Home Mortgage Disclosure) to reflect a change in the asset-size exemption threshold for banks, savings associations, and credit unions based on the annual percentage change in the Consumer Price Index for Urban Wage Earners and Clerical Workers (CPI-W). The exemption threshold is adjusted to increase to $42 million from $41 million. The adjustment is based on the 2.23 percent increase in the average of the CPI-W for the 12-month period ending in November 2012. Therefore, banks, savings associations, and credit unions with assets of $42 million or less as of December 31, 2012, are exempt from collecting data in 2013.
78 FR 79285 - Home Mortgage Disclosure (Regulation C): Adjustment to Asset-Size Exemption Threshold
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-30
...The Bureau of Consumer Financial Protection (Bureau) is publishing a final rule amending the official commentary that interprets the requirements of the Bureau's Regulation C (Home Mortgage Disclosure) to reflect a change in the asset-size exemption threshold for banks, savings associations, and credit unions based on the annual percentage change in the Consumer Price Index for Urban Wage Earners and Clerical Workers (CPI-W). The exemption threshold is adjusted to increase to $43 million from $42 million. The adjustment is based on the 1.4 percent increase in the average of the CPI-W for the 12-month period ending in November 2013. Therefore, banks, savings associations, and credit unions with assets of $43 million or less as of December 31, 2013, are exempt from collecting data in 2014.
Athlete and Non-Athlete Adjustment to College
ERIC Educational Resources Information Center
Drum, Jennifer; Ladda, Shawn; Geary, Colette; Fitzpatrick, Corine
2014-01-01
This study examined college adjustment between athletes and non-athletes at Manhattan College, a medium-sized college participating in NCAA Division I athletics located in the Bronx, New York. Groups included a total of fifty-two athletes, fifty-six non-athletes, twenty-five female athletes, twenty-seven male athletes, twenty-six female…
When Parents Divorce: Assisting Teens to Adjust through a Group Approach.
ERIC Educational Resources Information Center
Studer, Jeannine R.; Allton, Judith A.
1996-01-01
Addresses factors that contribute to the adjustment difficulties of children and adolescents when their parents divorce. Gender issues, custody, age, parenting style, visitation patterns, socioeconomic considerations, the support system, family size, and the reconstituted family are all discussed. Describes a model for an effective support group…
NASA Astrophysics Data System (ADS)
Tian, Baoqing; Xu, Peifen; Ling, Suqun; Du, Jianguo; Xu, Xueqiu; Pang, Zhonghe
2017-10-01
Geophysical techniques are critical tools of geothermal resource surveys. In recent years, the microtremor survey method, which has two branch techniques (the microtremor sounding technique and the two-dimensional (2D) microtremor profiling technique), has become a common method for geothermal resource exploration. The results of microtremor surveys provide important deep information for probing structures of geothermal storing basins and researching the heat-controlling structures, as well as providing the basis for drilling positions of geothermal wells. In this paper, the southern Jiangsu geothermal resources area is taken as a study example. By comparing the results of microtremor surveys and drilling conclusions, and analyzing microtremor survey effectiveness, and geological and technical factors such as observation radius and sampling frequency, we study the applicability of the microtremor survey method and the optimal way of working with this method to achieve better detection results. A comparative study of survey results and geothermal drilling results shows that the microtremor sounding technique effectively distinguishes sub-layers and determines the depth of geothermal reservoirs in the area with excellent layer conditions. The error of depth is generally no more than 8% compared with the results of drilling. It detects deeper by adjusting the size of the probing radius. The 2D microtremor profiling technique probes exactly the buried structures which display as low velocity anomalies in the apparent velocity profile of the S-wave. The anomaly is the critical symbol of the 2D microtremor profiling technique to distinguish and explain the buried geothermal structures. 2D microtremor profiling results provide an important basis for locating exactly the geothermal well and reducing the risk of drilling dry wells.
Adjustable speed drive study, June 1985 to September 1988. Part 2: Appendices
NASA Astrophysics Data System (ADS)
Wallace, Alan
1989-08-01
Advances in speed control for motors in recent years, notably those in power electronics, have widened the range of application for several adjustable speed drive (ASD) types to include the smaller horsepower sizes. The dc motor drive, formerly in almost universal use for speed control, is being challenged by the high efficiency induction motor/pulse width modulation (PWM) drive; and for special small horsepower size applications, by the permanent magnet motor/PWM inverter drive or by the switched reluctance motor drive. The main characteristics of the several ASD types suitable for small horsepower size applications are discussed, as well as their unwanted side effects: poor power factor, harmonic distortion of the supply, acoustic noise, and electromagnetic interference. A procedure is recommended for determining which, if any, ASD to use.
Three-dimensional stochastic adjustment of volcano geodetic network in Arenal volcano, Costa Rica
NASA Astrophysics Data System (ADS)
Muller, C.; van der Laat, R.; Cattin, P.-H.; Del Potro, R.
2009-04-01
Volcano geodetic networks are a key instrument to understanding magmatic processes and, thus, forecasting potentially hazardous activity. These networks are extensively used on volcanoes worldwide and generally comprise a number of different traditional and modern geodetic surveying techniques such as levelling, distances, triangulation and GNSS. However, in most cases, data from the different methodologies are surveyed, adjusted and analysed independently. Experience shows that the problem with this procedure is the mismatch between the excellent correlation of position values within a single technique and the low cross-correlation of such values within different techniques or when the same network is surveyed shortly after using the same technique. Moreover one different independent network for each geodetic surveying technique strongly increase logistics and thus the cost of each measurement campaign. It is therefore important to develop geodetic networks which combine the different geodetic surveying technique, and to adjust geodetic data together in order to better quantify the uncertainties associated to the measured displacements. In order to overcome the lack of inter-methodology data integration, the Geomatic Institute of the University of Applied Sciences of Western Switzerland (HEIG-VD) has developed a methodology which uses a 3D stochastic adjustment software of redundant geodetic networks, TRINET+. The methodology consists of using each geodetic measurement technique for its strengths relative to other methodologies. Also, the combination of the measurements in a single network allows more cost-effective surveying. The geodetic data are thereafter adjusted and analysed in the same referential frame. The adjustment methodology is based on the least mean square method and links the data with the geometry. Trinet+ also allows to run a priori simulations of the network, hence testing the quality and resolution to be expected for a determined network even before it is built. Moreover, a posterior analysis enables identifying, and hence dismissing, measurement errors (antenna height, atmospheric effects, etc.). Here we present a preliminary effort to apply this technique to volcano deformation. A geodetic network has been developed on the western flank of the Arenal volcano in Costa Rica. It is surveyed with GNSS, angular and EDM (Electronic Distance Measurements) measurements. Three measurement campaigns were carried out between February and June 2008. The results show consistent and accurate output of deformation and uncertainty for each of the 12 benchmarks surveyed. The three campaigns also prove the repeatability and consistency of the statistical indicators and the displacement vectors. Although, this methodology has only recently been applied to volcanoes, we suggest that due to its cost-effective high-quality results it has the potential to be incorporated into the design and analysis of volcano geodetic networks worldwide.
Guarnieri, Adriano; Moreno-Montañés, Javier; Sabater, Alfonso L; Gosende-Chico, Inmaculada; Bonet-Farriol, Elvira
2013-11-01
To analyze the changes in incision sizes after implantation of a toric intraocular lens (IOL) using 2 methods. Department of Ophthalmology, Clínica Universidad de Navarra, Pamplona, Spain. Prospective case series. Coaxial phacoemulsification and IOL implantation through a 2.2 mm clear corneal incision using a cartridge injector were performed. Wound-assisted or cartridge-insertion techniques were used to implant the IOLs. The results were analyzed according to IOL spherical and cylindrical powers. Corneal hysteresis (CH) and the corneal resistance factor (CRF) were measured and evaluated based on the changes in incision size. Incision size increased in 30 (41.7%) of 72 eyes in the wound-assisted group and 71 (98.6%) of 72 eyes in the cartridge-insertion group. The mean incision size after IOL implantation was 2.27 mm ± 0.06 (SD) and 2.37 ± 0.05 mm, respectively (P<.01). The final incision size and IOL spherical power in the wound-assisted technique group (P=.02) and the cartridge-insertion technique group (P=.03) were correlated significantly; IOL toricity was not (P=.19 and P=.28, respectively). The CH and CRF values were not correlated with the final incision size. The final incision size and the changes in incision size after IOL implantation were greater with the cartridge-insertion technique than with the wound-assisted technique. The increase was related to IOL spherical power in both groups but not to IOL toricity. Corneal biomechanical properties were not correlated with the final incision size. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Comparison of two ways of altering carpal tunnel pressure with ultrasound surface wave elastography.
Cheng, Yu-Shiuan; Zhou, Boran; Kubo, Kazutoshi; An, Kai-Nan; Moran, Steven L; Amadio, Peter C; Zhang, Xiaoming; Zhao, Chunfeng
2018-06-06
Higher carpal tunnel pressure is related to the development of carpal tunnel syndrome. Currently, the measurement of carpal tunnel pressure is invasive and therefore, a noninvasive technique is needed. We previously demonstrated that speed of wave propagation through a tendon in the carpal tunnel measured by ultrasound elastography could be used as an indicator of carpal tunnel pressure in a cadaveric model, in which a balloon had to be inserted into the carpal tunnel to adjust the carpal tunnel pressure. However, the method for adjusting the carpal tunnel pressure in the cadaveric model is not applicable for the in vivo model. The objective of this study was to utilize a different technique to adjust carpal tunnel pressure via pressing the palm and to validate it with ultrasound surface wave elastography in a human cadaveric model. The outcome was also compared with a previous balloon insertion technique. Results showed that wave speed of intra-carpal tunnel tendon and the ratio of wave speed of intra-and outer-carpal tunnel tendons increased linearly with carpal tunnel pressure. Moreover, wave speed of intra carpal tunnel tendon via both ways of altering carpal tunnel pressure showed similar results with high correlation. Therefore, it was concluded that the technique of pressing the palm can be used to adjust carpal tunnel pressure, and pressure changes can be detected via ultrasound surface wave elastography in an ex vivo model. Future studies will utilize this technique in vivo to validate the usefulness of ultrasound surface wave elastography for measuring carpal tunnel pressure. Copyright © 2018 Elsevier Ltd. All rights reserved.
Sánchez Pérez, A; Honrubia López, F M; Larrosa Poves, J M; Polo Llorens, V; Melcon Sánchez-Frieras, B
2001-09-01
To develop a lens planimetry technique for the optic disc using AutoCAD. To determine variability magnitude of the optic disc morphological measurements. We employed AutoCAD R.14.0 Autodesk: image acquisition, contour delimitation by multiple lines fitting or ellipse adjustment, image sectorialization and measurements quantification (optic disc and excavation, vertical diameters, optic disc area, excavation area, neuroretinal sector area and Beta atrophy area). Intraimage or operator and interimage o total reproducibility was studied by coefficient of variability (CV) (n=10) in normal and myopic optic discs. This technique allows to obtain optic disc measurement in 5 to 10 minutes time. Total or interimage variability of measurements introduced by one observer presents CV range from 1.18-4.42. Operator or intraimage measurement presents CV range from 0.30-4.21. Optic disc contour delimitation by ellipse adjustment achieved better reproducibility results than multiple lines adjustment in all measurements. Computer assisted AutoCAD planimetry is an interactive method to analyse the optic disc, feasible to incorporate to clinical practice. Reproducibility results are comparable to other analyzers in quantification optic disc morphology. Ellipse adjustment improves results in optic disc contours delimitation.
Evaluation of the occlusal contact of crowns fabricated with the bite impression method.
Makino, Sachi; Okada, Daizo; Shin, Chiharu; Ogura, Reiko; Ikeda, Masaomi; Miura, Hiroyuki
2013-09-30
In prosthodontic treatment, reconstruction of a proper occlusal contact relationship is very important as well as reconstruction of a proper interproximal relationship and marginal fitness. Unfortunately, occlusal relationships are sometimes lost in the process of occlusal adjustment of crowns. The purpose of this study was to compare the occlusal contacts of single crown fabricated by two different types of impression techniques. Nine subjects, whose molars required treatment with crown restoration, were enrolled in this study. Full cast crowns were fabricated using two types of impression techniques: the conventional impression method (CIM) and the bite impression method (BIM). The occlusal contacts of crowns were precisely evaluated at the following stages: after occlusal adjustment on the articulator (Step 0), before occlusal adjustment in the mouth (Step 1), after occlusal adjustment at the intercuspal position (Step 2), and after occlusal adjustment during lateral and protrusive excursions (Step 3). The number of occlusal contacts of the crowns on the functional cusps fabricated with BIM was significantly greater than that with CIM after occlusal adjustment. For this reason, the crowns fabricated with BIM might have a more functionally desirable occlusal surface compared to the crowns fabricated with CIM.
de Freitas, Paulo B; Jaric, Slobodan
2009-04-01
We evaluated coordination of the hand grip force (GF; normal component of the force acting at the hand-object contact area) and load force (LF; the tangential component) in a variety of grasping techniques and two LF directions. Thirteen participants exerted a continuous sinusoidal LF pattern against externally fixed handles applying both standard (i.e., using either the tips of the digits or the palms; the precision and palm grasps, respectively) and non-standard grasping techniques (using wrists and the dorsal finger areas; the wrist and fist grasp). We hypothesized (1) that the non-standard grasping techniques would provide deteriorated indices of force coordination when compared with the standard ones, and (2) that the nervous system would be able to adjust GF to the differences in friction coefficients of various skin areas used for grasping. However, most of the indices of force coordination remained similar across the tested grasping techniques, while the GF adjustments for the differences in friction coefficients (highest in the palm and the lowest in the fist and wrist grasp) provided inconclusive results. As hypothesized, GF relative to the skin friction was lowest in the precision grasp, but highest in the palm grasp. Therefore, we conclude that (1) the elaborate coordination of GF and LF consistently seen across the standard grasping techniques could be generalized to the non-standard ones, while (2) the ability to adjust GF using the same grasping technique to the differences in friction of various objects cannot be fully generalized to the GF adjustment when different grasps (i.e., hand segments) are used to manipulate the same object. Due to the importance of the studied phenomena for understanding both the functional and neural control aspects of manipulation, future studies should extend the current research to the transient and dynamic tasks, as well as to the general role of friction in our mechanical interactions with the environment.
50 CFR 648.127 - Framework adjustments to management measures.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., FMP Monitoring Committee composition and process, description and identification of essential fish... additions to management measures must come from one or more of the following categories: Minimum fish size, maximum fish size, gear restrictions, gear restricted areas, gear requirements or prohibitions, permitting...
Li, Yajie; Zhao, Yongli; Zhang, Jie; Yu, Xiaosong; Jing, Ruiquan
2017-11-27
Network operators generally provide dedicated lightpaths for customers to meet the demand for high-quality transmission. Considering the variation of traffic load, customers usually rent peak bandwidth that exceeds the practical average traffic requirement. In this case, bandwidth provisioning is unmetered and customers have to pay according to peak bandwidth. Supposing that network operators could keep track of traffic load and allocate bandwidth dynamically, bandwidth can be provided as a metered service and customers would pay for the bandwidth that they actually use. To achieve cost-effective bandwidth provisioning, this paper proposes an autonomic bandwidth adjustment scheme based on data analysis of traffic load. The scheme is implemented in a software defined networking (SDN) controller and is demonstrated in the field trial of multi-vendor optical transport networks. The field trial shows that the proposed scheme can track traffic load and realize autonomic bandwidth adjustment. In addition, a simulation experiment is conducted to evaluate the performance of the proposed scheme. We also investigate the impact of different parameters on autonomic bandwidth adjustment. Simulation results show that the step size and adjustment period have significant influences on bandwidth savings and packet loss. A small value of step size and adjustment period can bring more benefits by tracking traffic variation with high accuracy. For network operators, the scheme can serve as technical support of realizing bandwidth as metered service in the future.
Gulliford, Martin C; Jack, Ruth H; Adams, Geoffrey; Ukoumunne, Obioha C
2004-01-01
Background It has been proposed that greater availability of primary medical care practitioners (GPs) contributes to better population health. We evaluated whether measures of the supply and structure of primary medical services are associated with health and health care indicators after adjusting for confounding. Methods Data for the supply and structure of primary medical services and the characteristics of registered patients were analysed for 99 health authorities in England in 1999. Health and health care indicators as dependent variables included standardised mortality ratios (SMR), standardised hospital admission rates, and conceptions under the age of 18 years. Linear regression analyses were adjusted for Townsend score, proportion of ethnic minorities and proportion of social class IV/ V. Results Higher proportions of registered rural patients and patients ≥ 75 years were associated with lower Townsend deprivation scores, with larger partnership sizes and with better health outcomes. A unit increase in partnership size was associated with a 4.2 (95% confidence interval 1.7 to 6.7) unit decrease in SMR for all-cause mortality at 15–64 years (P = 0.001). A 10% increase in single-handed practices was associated with a 1.5 (0.2 to 2.9) unit increase in SMR (P = 0.027). After additional adjustment for percent of rural and elderly patients, partnership size and proportion of single-handed practices, GP supply was not associated with SMR (-2.8, -6.9 to 1.3, P = 0.183). Conclusions After adjusting for confounding with health needs of populations, mortality is weakly associated with the degree of organisation of practices as represented by the partnership size but not with the supply of GPs. PMID:15193157
Food insecurity, food assistance and weight status in US youth: new evidence from NHANES 2007-08.
Kohn, M J; Bell, J F; Grow, H M G; Chan, G
2014-04-01
To investigate food assistance participation as a risk factor for overweight and obesity in youth, and food insecurity as an effect modifier. The sample included youth ages 4-17, in families ≤200% of the federal poverty line in the 2007-2008 National Health and Nutrition Examination Survey (n = 1321). Food insecurity was measured with the US Department of Agriculture survey module. Food assistance participation was assessed for Supplemental Nutrition Assistance Program, Special Supplemental Nutrition Program for Women, Infants and Children and school meals. Body size was classified by age- and sex-specific body mass index (BMI) percentile, BMI z-score and waist circumference percentile. Regression models with direct covariate adjustment and programme-specific propensity scores, stratified by food insecurity, estimated associations between food assistance participation and body size. Food assistance participation was not associated with increased body size among food-insecure youth in models with direct covariate adjustment or propensity scores. Compared with low-income, food-secure youth not participating in food assistance, BMI z-scores were higher among participants in models with direct covariate adjustment (0.27-0.38 SD and 0.41-0.47 SD, for boys and girls, respectively). Using propensity scores, results were similar for boys, but less so for girls. Food assistance programme participation is associated with increased body size in food-secure youth, but not food-insecure youth. Using both direct covariate adjustment and a propensity score approach, self-selection bias may explain some, but not all, of the associations. Providing healthy food assistance that improves diet quality without contributing to excessive intake remains an important public health goal. © 2013 The Authors. Pediatric Obesity © 2013 International Association for the Study of Obesity.
Using a conformal water bolus to adjust heating patterns of microwave waveguide applicators
NASA Astrophysics Data System (ADS)
Stauffer, Paul R.; Rodrigues, Dario B.; Sinahon, Randolf; Sbarro, Lyndsey; Beckhoff, Valeria; Hurwitz, Mark D.
2017-02-01
Background: Hyperthermia, i.e., raising tissue temperature to 40-45°C for 60 min, has been demonstrated to increase the effectiveness of radiation and chemotherapy for cancer. Although multi-element conformal heat applicators are under development to provide more adjustable heating of contoured anatomy, to date the most often used applicator to heat superficial disease is the simple microwave waveguide. With only a single power input, the operator must be resourceful to adjust heat treatment to accommodate variable size and shape tumors spreading across contoured anatomy. Methods: We used multiphysics simulation software that couples electromagnetic, thermal and fluid dynamics physics to simulate heating patterns in superficial tumors from commercially available microwave waveguide applicators. Temperature distributions were calculated inside homogenous muscle and layered skin-fat-muscle-tumor-bone tissue loads for a typical range of applicator coupling configurations and size of waterbolus. Variable thickness waterbolus was simulated as necessary to accommodate contoured anatomy. Physical models of several treatment configurations were constructed for comparison of simulation results with experimental specific absorption rate (SAR) measurements in homogenous muscle phantom. Results: Accuracy of the simulation model was confirmed with experimental SAR measurements of three unique applicator setups. Simulations demonstrated the ability to generate a wide range of power deposition patterns with commercially available waveguide antennas by controllably varying size and thickness of the waterbolus layer. Conclusion: Heating characteristics of 915 MHz waveguide antennas can be varied over a wide range by controlled adjustment of microwave power, coupling configuration, and waterbolus lateral size and thickness. The uniformity of thermal dose delivered to superficial tumors can be improved by cyclic switching of waterbolus thickness during treatment to proactively shift heat peaks and nulls around under the aperture, thereby reducing patient pain while increasing minimum thermal dose by end of treatment.
Female freshwater crayfish adjust egg and clutch size in relation to multiple male traits
Galeotti, Paolo; Rubolini, Diego; Fea, Gianluca; Ghia, Daniela; Nardi, Pietro A; Gherardi, Francesca; Fasola, Mauro
2006-01-01
Females may invest more in reproduction if they acquire mates of high phenotypic quality, because offspring sired by preferred partners may be fitter than offspring sired by non-preferred ones. In this study, we tested the differential maternal allocation hypothesis in the freshwater crayfish, Austropotamobius italicus, by means of a pairing experiment aimed at evaluating the effects of specific male traits (body size, chelae size and chelae asymmetry) on female primary reproductive effort. Our results showed that females laid larger but fewer eggs for relatively small-sized, large-clawed males, and smaller but more numerous eggs for relatively large-sized, small-clawed males. Chelae asymmetry had no effects on female reproductive investment. While the ultimate consequences of this pattern of female allocation remain unclear, females were nevertheless able to adjust their primary reproductive effort in relation to mate characteristics in a species where inter-male competition and sexual coercion may mask or obscure their sexual preferences. In addition, our results suggest that female allocation may differentially affect male characters, thus promoting a trade-off between the expression of different male traits. PMID:16600888
Investigations of internal noise levels for different target sizes, contrasts, and noise structures
NASA Astrophysics Data System (ADS)
Han, Minah; Choi, Shinkook; Baek, Jongduk
2014-03-01
To describe internal noise levels for different target sizes, contrasts, and noise structures, Gaussian targets with four different sizes (i.e., standard deviation of 2,4,6 and 8) and three different noise structures(i.e., white, low-pass, and highpass) were generated. The generated noise images were scaled to have standard deviation of 0.15. For each noise type, target contrasts were adjusted to have the same detectability based on NPW, and the detectability of CHO was calculated accordingly. For human observer study, 3 trained observers performed 2AFC detection tasks, and correction rate, Pc, was calculated for each task. By adding proper internal noise level to numerical observer (i.e., NPW and CHO), detectability of human observer was matched with that of numerical observers. Even though target contrasts were adjusted to have the same detectability of NPW observer, detectability of human observer decreases as the target size increases. The internal noise level varies for different target sizes, contrasts, and noise structures, demonstrating different internal noise levels should be considered in numerical observer to predict the detection performance of human observer.
Hjortebjerg, Dorrit; Andersen, Anne Marie Nybo; Ketzel, Matthias; Pedersen, Marie; Raaschou-Nielsen, Ole; Sørensen, Mette
2016-10-01
Maternal exposure to air pollution and traffic noise has been suggested to impair fetal growth, but studies have reported inconsistent findings. Objective To investigate associations between residential air pollution and traffic noise during pregnancy and newborn's size at birth. From a national birth cohort we identified 75,166 live-born singletons born at term with information on the children's size at birth. Residential address history from conception until birth was collected and air pollution (NO2 and NOx) and road traffic noise was modeled at all addresses. Associations between exposures and indicators of newborn's size at birth: birth weight, placental weight and head and abdominal circumference were analyzed by linear and logistic regression, and adjusted for potential confounders. In mutually adjusted models we found a 10μg/m(3) higher time-weighted mean exposure to NO2 during pregnancy to be associated with a 0.35mm smaller head circumference (95% confidence interval (CI): 95% CI: -0.57; -0.12); a 0.50mm smaller abdominal circumference (95% CI: -0.80; -0.20) and a 5.02g higher placental weight (95% CI: 2.93; 7.11). No associations were found between air pollution and birth weight. Exposure to residential road traffic noise was weakly associated with reduced head circumference, whereas none of the other newborn's size indicators were associated with noise, neither before nor after adjustment for air pollution. This study indicates that air pollution may result in a small reduction in offspring's birth head and abdominal circumference, but not birth weight, whereas traffic noise seems not to affect newborn's size at birth. Copyright © 2016 Elsevier Ltd. All rights reserved.
Demand-Adjusted Shelf Availability Parameters: A Second Look.
ERIC Educational Resources Information Center
Schwarz, Philip
1983-01-01
Data gathered in application of Paul Kantor's demand-adjusted shelf availability model to medium-sized academic library indicate significant differences in shelf availability when data are analyzed by last circulation date, acquisition date, and imprint date, and when they are gathered during periods of low and high use. Ten references are cited.…
16 CFR 1509.3 - Crib-side height.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Crib-side height. 1509.3 Section 1509.3... REQUIREMENTS FOR NON-FULL-SIZE BABY CRIBS § 1509.3 Crib-side height. (a) With the mattress support in its highest adjustable position and the crib side in its lowest adjustable position, the vertical distance...
16 CFR 1509.3 - Crib-side height.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Crib-side height. 1509.3 Section 1509.3... REQUIREMENTS FOR NON-FULL-SIZE BABY CRIBS § 1509.3 Crib-side height. (a) With the mattress support in its highest adjustable position and the crib side in its lowest adjustable position, the vertical distance...
13 CFR 124.1007 - Who may protest the disadvantaged status of a concern?
Code of Federal Regulations, 2012 CFR
2012-01-01
... successful offeror has invoked an SDB evaluation adjustment or an SDB set-aside, the following entities may... evaluation adjustment for proposing one or more SDB subcontractors, the procuring activity contracting... status and size of an apparent successful SDB offeror must submit two separate protests, one as to...
13 CFR 124.1007 - Who may protest the disadvantaged status of a concern?
Code of Federal Regulations, 2014 CFR
2014-01-01
... successful offeror has invoked an SDB evaluation adjustment or an SDB set-aside, the following entities may... evaluation adjustment for proposing one or more SDB subcontractors, the procuring activity contracting... status and size of an apparent successful SDB offeror must submit two separate protests, one as to...
13 CFR 124.1007 - Who may protest the disadvantaged status of a concern?
Code of Federal Regulations, 2013 CFR
2013-01-01
... successful offeror has invoked an SDB evaluation adjustment or an SDB set-aside, the following entities may... evaluation adjustment for proposing one or more SDB subcontractors, the procuring activity contracting... status and size of an apparent successful SDB offeror must submit two separate protests, one as to...
13 CFR 124.1007 - Who may protest the disadvantaged status of a concern?
Code of Federal Regulations, 2011 CFR
2011-01-01
... successful offeror has invoked an SDB evaluation adjustment or an SDB set-aside, the following entities may... evaluation adjustment for proposing one or more SDB subcontractors, the procuring activity contracting... status and size of an apparent successful SDB offeror must submit two separate protests, one as to...
13 CFR 124.1007 - Who may protest the disadvantaged status of a concern?
Code of Federal Regulations, 2010 CFR
2010-01-01
... successful offeror has invoked an SDB evaluation adjustment or an SDB set-aside, the following entities may... evaluation adjustment for proposing one or more SDB subcontractors, the procuring activity contracting... status and size of an apparent successful SDB offeror must submit two separate protests, one as to...
ERIC Educational Resources Information Center
Kenney, Shannon R.; Lac, Andrew; Hummer, Justin F.; Grimaldi, Elizabeth M.; LaBrie, Joseph W.
2015-01-01
This study examined the pathways of parenting style (permissive, authoritarian, and authoritative) to alcohol consumption and consequences through the mediators of college adjustment and academic achievement (grade point average [GPA]). Participants were 289 students from a private, mid-size, West Coast university (mean age 19.01 years, 58.8%…
Bench-top soldering aid for PC boards
NASA Technical Reports Server (NTRS)
Manton, N. R.; Schroff, R. A.
1978-01-01
Multiple-board rack allows technician to insert components into several boards, flip them all in single motion, and then systematically solder leads on reverse side. Two adjustable crossbars allow boards of any size up to 10 by 24 inches. Operator can rotate racks and adjust angle of boards from standing or sitting position.
Zhou, Yuhang; Li, Junjie; Zhang, Ying; Dong, Dianyu; Zhang, Ershuai; Ji, Feng; Qin, Zhihui; Yang, Jun; Yao, Fanglian
2017-02-02
Prediction of the diffusion coefficient of solute, especially bioactive molecules, in hydrogel is significant in the biomedical field. Considering the randomness of solute movement in a hydrogel network, a physical diffusion RMP-1 model based on obstruction theory was established in this study. The physical properties of the solute and the polymer chain and their interactions were introduced into this model. Furthermore, models RMP-2 and RMP-3 were established to understand and predict the diffusion behaviors of proteins in hydrogel. In addition, zwitterionic poly(sulfobetaine methacrylate) (PSBMA) hydrogels with wide range and fine adjustable mesh sizes were prepared and used as efficient experimental platforms for model validation. The Flory characteristic ratios, Flory-Huggins parameter, mesh size, and polymer chain radii of PSBMA hydrogels were determined. The diffusion coefficients of the proteins (bovine serum albumin, immunoglobulin G, and lysozyme) in PSBMA hydrogels were studied by the fluorescence recovery after photobleaching technique. The measured diffusion coefficients were compared with the predictions of obstruction models, and it was found that our model presented an excellent predictive ability. Furthermore, the assessment of our model revealed that protein diffusion in PSBMA hydrogel would be affected by the physical properties of the protein and the PSBMA network. It was also confirmed that the diffusion behaviors of protein in zwitterionic hydrogels can be adjusted by changing the cross-linking density of the hydrogel and the ionic strength of the swelling medium. Our model is expected to possess accurate predictive ability for the diffusion coefficient of solute in hydrogel, which will be widely used in the biomedical field.
NASA Astrophysics Data System (ADS)
Soldatov, A. P.
2017-05-01
As part of ongoing studies aimed at designing the next generation of nanosized membrane reactors (NMRs) with accumulated hydrogen, the noncatalytic hydrogenation of naphthalene in pores of ceramic membranes (TRUMEM ultrafiltration membranes with D av = 50 and 90 nm) is performed for the first time, using hydrogen preadsorbed in a hybrid carbon nanostructure: mono- and multilayered oriented carbon nanotubes with graphene walls (OCNTGs) that form on inner pore surfaces. In this technique, the reaction proceeds in the temperature range of 330-390°C at contact times of 10-16 h. The feedstock is an 8% naphthalene solution in decane. The products are analyzed via chromatography on a quartz capillary column coated with polydimethylsiloxane (SE-30). It is established for the first time that in NMRs, the noncatalytic hydrogenation of naphthalene occurs at 370-390°C, forming 1,2,3,4-tetrahydronaphthalene in amounts of up to 0.61%. The rate constants and activation energy (123.5 kJ/mol) of the noncatalytic hydrogenation reaction are determined for the first time. The possibility of designing an NMR with an adjustable reaction zone volume is explored. Changes in the pore structure of the membranes after their modification with pyrocarbon nanosized crystallites (PNCs) are therefore studied as well. It is shown that lengthening the process time reduces pore size: within 23 h after the deposition of PNCs, the average pore radius ( r av) falls from 25 to 3.1 nm. The proposed approach would allow us to design nanoreactors of molecular size and conduct hydrogenation reactions within certain guidelines to synthesize new chemical compounds.
A Comparison of the Multiscale Retinex With Other Image Enhancement Techniques
NASA Technical Reports Server (NTRS)
Rahman, Zia-Ur; Woodell, Glenn A.; Jobson, Daniel J.
1997-01-01
The multiscale retinex with color restoration (MSRCR) has shown itself to be a very versatile automatic image enhancement algorithm that simultaneously provides dynamic range compression, color constancy, and color rendition. A number of algorithms exist that provide one or more of these features, but not all. In this paper we compare the performance of the MSRCR with techniques that are widely used for image enhancement. Specifically, we compare the MSRCR with color adjustment methods such as gamma correction and gain/offset application, histogram modification techniques such as histogram equalization and manual histogram adjustment, and other more powerful techniques such as homomorphic filtering and 'burning and dodging'. The comparison is carried out by testing the suite of image enhancement methods on a set of diverse images. We find that though some of these techniques work well for some of these images, only the MSRCR performs universally well on the test set.
Liu, Xiaofeng Steven
2011-05-01
The use of covariates is commonly believed to reduce the unexplained error variance and the standard error for the comparison of treatment means, but the reduction in the standard error is neither guaranteed nor uniform over different sample sizes. The covariate mean differences between the treatment conditions can inflate the standard error of the covariate-adjusted mean difference and can actually produce a larger standard error for the adjusted mean difference than that for the unadjusted mean difference. When the covariate observations are conceived of as randomly varying from one study to another, the covariate mean differences can be related to a Hotelling's T(2) . Using this Hotelling's T(2) statistic, one can always find a minimum sample size to achieve a high probability of reducing the standard error and confidence interval width for the adjusted mean difference. ©2010 The British Psychological Society.
Sawicki, R.H.; Sweatt, W.
1985-11-21
A technique for adjustably correcting for astigmatism in a light beam is disclosed herein. This technique defines a flat, rectangular light reflecting surface having opposite reinforced side edges and which is resiliently bendable, to a limited extent, into different concave and/or convex cylindrical curvatures about a particular axis and provides for adjustably bending the light reflecting surface into one of different curvatures depending upon the astigmatism to be corrected and for fixedly maintaining the curvature selected. In the embodiment disclosed, the light reflecting surface is adjustably bendable into the selected cylindrical curvature by application of a particular bending moment to the reinforced side edges of the light reflecting surface.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sawicki, R.H.; Sweatt, W.
1985-11-21
A technique for adjustably correcting for astigmatism in a light beam is disclosed herein. This technique defines a flat, rectangular light reflecting surface having opposite reinforced side edges and which is resiliently bendable, to a limited extent, into different concave and/or convex cylindrical curvatures about a particular axis and provides for adjustably bending the light reflecting surface into one of different curvatures depending upon the astigmatism to be corrected and for fixedly maintaining the curvature selected. In the embodiment disclosed, the light reflecting surface is adjustably bendable into the selected cylindrical curvature by application of a particular bending moment tomore » the reinforced side edges of the light reflecting surface.« less
Evolving concepts on adjusting human resting energy expenditure measurements for body size.
Heymsfield, S B; Thomas, D; Bosy-Westphal, A; Shen, W; Peterson, C M; Müller, M J
2012-11-01
Establishing if an adult's resting energy expenditure (REE) is high or low for their body size is a pervasive question in nutrition research. Early workers applied body mass and height as size measures and formulated the Surface Law and Kleiber's Law, although each has limitations when adjusting REE. Body composition methods introduced during the mid-20th century provided a new opportunity to identify metabolically homogeneous 'active' compartments. These compartments all show improved correlations with REE estimates over body mass-height approaches, but collectively share a common limitation: REE-body composition ratios are not 'constant' but vary across men and women and with race, age and body size. The now-accepted alternative to ratio-based norms is to adjust for predictors by applying regression models to calculate 'residuals' that establish if an REE is relatively high or low. The distinguishing feature of statistical REE-body composition models is a 'non-zero' intercept of unknown origin. The recent introduction of imaging methods has allowed development of physiological tissue-organ-based REE prediction models. Herein, we apply these imaging methods to provide a mechanistic explanation, supported by experimental data, for the non-zero intercept phenomenon and, in that context, propose future research directions for establishing between-subject differences in relative energy metabolism. © 2012 The Authors. obesity reviews © 2012 International Association for the Study of Obesity.
Size Estimation in Schizophrenic and Nonschizophrenic Subjects
ERIC Educational Resources Information Center
Kopfstein, Joan Held; Neale, John M.
1971-01-01
The results of this study showed no significant differences in the size estimation levels of acute and chronic schizophrenic and nonschizophrenic psychiatric patients. Also, there were no significant differences when these groups were subdivided on the basis of both premorbid adjustment and paranoid status. (Author/CG)
Electromigration Reliability of Advanced Interconnects
NASA Astrophysics Data System (ADS)
Hu, C.-K.; Gignac, L. M.; Baker-O'Neal, B.; Liniger, E.; Yu, R.; Flaitz, P.; Stamper, A. K.
2007-10-01
Electromigration behavior in Cu damascene wires was studied for various metal line widths, thicknesses and grain sizes where the grain size was modulated by Cu linewidth and thickness, and by adjusting the wafer annealing process step after Cu electroplating and before Cu chemical mechanical polishing. Significantly different results were found between 0.2 μm and 65 nm CMOS node technologies. A larger variation of Cu grain size between the samples was achieved on 65 nm node which was due to the finer line width and thinner metal thickness. The Cu lifetime and mass flow in samples with bamboo, near bamboo, bamboo-polycrystalline mixture, and polycrystalline grain structures were measured. These factors allow one to accurately resolve the relative contribution between grain boundary and interface diffusions in the Cu nanowires. The electromigration mass flow estimated from the lifetime on the test line on a W via and physically stable liner was found to be linearly proportional to current density. The effects of Cu(Ti) alloy seeds and Cu surface pre-clean techniques before the dielectric cap depositions on Cu electromigration were also observed. A significantly improved Cu lifetime, at the expense of the Cu conductivity, was found. The electromigration activation energies for Cu in Cu(Ti) alloy, along Cu/amorphous a-SiCxNyHz interface and in Cu grain boundaries were found to be 1.3, 0.95 and 0.79+0.05 eV, respectively.
Rakhmatullina, Ekaterina; Bossen, Anke; Bachofner, Kai K; Meier, Christoph; Lussi, Adrian
2013-11-01
Application of the specular reflection intensity was previously reported for the quantification of early dental erosion. Further development of the technique and assembly of the miniaturized pen-size instrument are described. The optical system was adjusted to fit into a handy device which could potentially access different positions in the oral cavity. The assembled instrument could successfully detect early erosion progression in both polished (n=70) and native (n=20) human enamels. Different severities of enamel erosion were induced by varying incubation time of polished enamel in 1% citric acid (pH=3.60, 0.5 to 10 min), while the native incisors were treated in the commercial orange juice (Tropicana Pure Premium®, pH=3.85, 10 to 60 min). The instrument provided a good differentiation between various severities of the erosion in vitro. The size of the measurement spot affected the erosion monitoring in native enamel (human incisors). The erosion measurement in the 0.7-mm (diameter) cervical spots showed systematically lower reflection intensities compared with the analysis of central and incisal small spots. The application of larger spot areas (2.3 mm) for the erosion monitoring revealed no effect (p>0.05) of the spot position on the reflection signal. High variation of the teeth susceptibility toward in vitro erosion was detected in native enamel.
NASA Astrophysics Data System (ADS)
Babick, Frank; Mielke, Johannes; Wohlleben, Wendel; Weigel, Stefan; Hodoroaba, Vasile-Dan
2016-06-01
Currently established and projected regulatory frameworks require the classification of materials (whether nano or non-nano) as specified by respective definitions, most of which are based on the size of the constituent particles. This brings up the question if currently available techniques for particle size determination are capable of reliably classifying materials that potentially fall under these definitions. In this study, a wide variety of characterisation techniques, including counting, fractionating, and spectroscopic techniques, has been applied to the same set of materials under harmonised conditions. The selected materials comprised well-defined quality control materials (spherical, monodisperse) as well as industrial materials of complex shapes and considerable polydispersity. As a result, each technique could be evaluated with respect to the determination of the number-weighted median size. Recommendations on the most appropriate and efficient use of techniques for different types of material are given.
Silverman, Rachel K; Ivanova, Anastasia
2017-01-01
Sequential parallel comparison design (SPCD) was proposed to reduce placebo response in a randomized trial with placebo comparator. Subjects are randomized between placebo and drug in stage 1 of the trial, and then, placebo non-responders are re-randomized in stage 2. Efficacy analysis includes all data from stage 1 and all placebo non-responding subjects from stage 2. This article investigates the possibility to re-estimate the sample size and adjust the design parameters, allocation proportion to placebo in stage 1 of SPCD, and weight of stage 1 data in the overall efficacy test statistic during an interim analysis.
Chae, Michael P; Hunter-Smith, David J; Rostek, Marie; Smith, Julian A; Rozen, Warren Matthew
2018-01-01
Optimizing preoperative planning is widely sought in deep inferior epigastric artery perforator (DIEP) flap surgery. One reason for this is that rates of fat necrosis remain relatively high (up to 35%), and that adjusting flap design by an improved understanding of individual perforasomes and perfusion characteristics may be useful in reducing the risk of fat necrosis. Imaging techniques have substantially improved over the past decade, and with recent advances in 3D printing, an improved demonstration of imaged anatomy has become available. We describe a 3D-printed template that can be used preoperatively to mark out a patient's individualized perforasome for flap planning in DIEP flap surgery. We describe this "perforasome template" technique in a case of a 46-year-old woman undergoing immediate unilateral breast reconstruction with a DIEP flap. Routine preoperative computed tomographic angiography was performed, with open-source software (3D Slicer, Autodesk MeshMixer and Cura) and a desktop 3D printer (Ultimaker 3E) used to create a template used to mark intra-flap, subcutaneous branches of deep inferior epigastric artery (DIEA) perforators on the abdomen. An individualized 3D printed template was used to estimate the size and boundaries of a perforasome and perfusion map. The information was used to aid flap design. We describe a new technique of 3D printing a patient-specific perforasome template that can be used preoperatively to infer perforasomes and aid flap design.
Hunter-Smith, David J.; Rostek, Marie; Smith, Julian A.; Rozen, Warren Matthew
2018-01-01
Summary: Optimizing preoperative planning is widely sought in deep inferior epigastric artery perforator (DIEP) flap surgery. One reason for this is that rates of fat necrosis remain relatively high (up to 35%), and that adjusting flap design by an improved understanding of individual perforasomes and perfusion characteristics may be useful in reducing the risk of fat necrosis. Imaging techniques have substantially improved over the past decade, and with recent advances in 3D printing, an improved demonstration of imaged anatomy has become available. We describe a 3D-printed template that can be used preoperatively to mark out a patient’s individualized perforasome for flap planning in DIEP flap surgery. We describe this “perforasome template” technique in a case of a 46-year-old woman undergoing immediate unilateral breast reconstruction with a DIEP flap. Routine preoperative computed tomographic angiography was performed, with open-source software (3D Slicer, Autodesk MeshMixer and Cura) and a desktop 3D printer (Ultimaker 3E) used to create a template used to mark intra-flap, subcutaneous branches of deep inferior epigastric artery (DIEA) perforators on the abdomen. An individualized 3D printed template was used to estimate the size and boundaries of a perforasome and perfusion map. The information was used to aid flap design. We describe a new technique of 3D printing a patient-specific perforasome template that can be used preoperatively to infer perforasomes and aid flap design. PMID:29464169
Prabhu, Anil; Tully, Phillip J; Bennetts, Jayme S; Tuble, Sigrid C; Baker, Robert A
2013-08-01
Though Indigenous Australian peoples reportedly have poorer survival outcome after cardiac surgery, few studies have jointly documented the experience of major morbidity, and considered the influence of patient geographic remoteness. From January 1998 to September 2008, major morbidity events and survival were recorded for 2748 consecutive patients undergoing coronary artery bypass graft surgery. Morbidity and survival analyses adjusted for propensity deciles based on patient ethnicity and age, sex, left ventricular ejection fraction, recent myocardial infarction, tobacco smoking, diabetes, renal disease and history of stroke. Sensitivity analyses controlled for the patient accessibility/remoteness index of Australia (ARIA). The 297 Indigenous Australian patients (10.8% of total) had greater odds for total morbidity (adjusted odds ratio = 1.55; 95% confidence interval [CI] 1.04-2.30) and prolonged ventilation (adjusted odds ratio = 2.08; 95% confidence interval [CI] 1.25-3.44) in analyses adjusted for propensity deciles and geographic remoteness. With a median follow-up of 7.5 years (interquartile range 5.2-10.2), Indigenous Australian patients were found to experience 30% greater mortality risk (unadjusted hazard ratio = 1.30; 95% CI: 1.03-1.64, p = 0.03). The effect size strengthened after adjustment for propensity score (adjusted hazard ratio = 1.49; 95% CI: 1.13-1.96, p = .004). Adjustment for ARIA categorisation strengthened the effect size (adjusted HR = 1.54 (95% CI: 1.11-2.13, p = .009). Indigenous Australian peoples were at greater risk for prolonged ventilation and combined morbidity outcome, and experienced poorer survival in the longer term. Higher mortality risk among Indigenous Australians was evident even after controlling for remoteness and accessibility to services. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.
Cursor Control Device Test Battery
NASA Technical Reports Server (NTRS)
Holden, Kritina; Sandor, Aniko; Pace, John; Thompson, Shelby
2013-01-01
The test battery was developed to provide a standard procedure for cursor control device evaluation. The software was built in Visual Basic and consists of nine tasks and a main menu that integrates the set-up of the tasks. The tasks can be used individually, or in a series defined in the main menu. Task 1, the Unidirectional Pointing Task, tests the speed and accuracy of clicking on targets. Two rectangles with an adjustable width and adjustable center- to-center distance are presented. The task is to click back and forth between the two rectangles. Clicks outside of the rectangles are recorded as errors. Task 2, Multidirectional Pointing Task, measures speed and accuracy of clicking on targets approached from different angles. Twenty-five numbered squares of adjustable width are arranged around an adjustable diameter circle. The task is to point and click on the numbered squares (placed on opposite sides of the circle) in consecutive order. Clicks outside of the squares are recorded as errors. Task 3, Unidirectional (horizontal) Dragging Task, is similar to dragging a file into a folder on a computer desktop. Task 3 requires dragging a square of adjustable width from one rectangle and dropping it into another. The width of each rectangle is adjustable, as well as the distance between the two rectangles. Dropping the square outside of the rectangles is recorded as an error. Task 4, Unidirectional Path Following, is similar to Task 3. The task is to drag a square through a tunnel consisting of two lines. The size of the square and the width of the tunnel are adjustable. If the square touches any of the lines, it is counted as an error and the task is restarted. Task 5, Text Selection, involves clicking on a Start button, and then moving directly to the underlined portion of the displayed text and highlighting it. The pointing distance to the text is adjustable, as well as the to-be-selected font size and the underlined character length. If the selection does not include all of the underlined characters, or includes non-underlined characters, it is recorded as an error. Task 6, Multi-size and Multi-distance Pointing, presents the participant with 24 consecutively numbered buttons of different sizes (63 to 163 pixels), and at different distances (60 to 80 pixels) from the Start button. The task is to click on the Start button, and then move directly to, and click on, each numbered target button in consecutive order. Clicks outside of the target area are errors. Task 7, Standard Interface Elements Task, involves interacting with standard interface elements as instructed in written procedures, including: drop-down menus, sliders, text boxes, radio buttons, and check boxes. Task completion time is recorded. In Task 8, a circular track is presented with a disc in it at the top. Track width and disc size are adjustable. The task is to move the disc with circular motion within the path without touching the boundaries of the track. Time and errors are recorded. Task 9 is a discrete task that allows evaluation of discrete cursor control devices that tab from target to target, such as a castle switch. The task is to follow a predefined path and to click on the yellow targets along the path.
Basmaci, F; Oztan, M D; Kiyan, M
2013-09-01
To evaluate ex vivo the effectiveness of single-file instrumentation techniques compared with serial Ni-Ti rotary instrumentation with several irrigation regimens in reducing E. faecalis within root canals. A total of 81 extracted human mandibular premolar teeth with a single root canal were infected with E. faecalis before and after canal preparation. Samples were divided randomly into 9 groups, as follows: group 1-A: sterile phosphate-buffered saline + Self-adjusting file, group 1-B: 5% sodium hypochlorite + 15% EDTA + Self-adjusting file, group 1-C: 5% sodium hypochlorite + 7% maleic acid + Self-adjusting file, group 2-A: sterile phosphate-buffered saline + Reciproc (R25), group 2-B: 5% sodium hypochlorite + 15% EDTA + Reciproc (R25), group 2-C: 5% sodium hypochlorite + 7% maleic acid + Reciproc (R25), group 3-A: sterile phosphate-buffered saline + ProTaper, group 3-B: 5% sodium hypochlorite + 15% EDTA + ProTaper, group 3-C: 5% sodium hypochlorite + 7% maleic acid + ProTaper. anova was used to analyse statistically the differences in terms of reduction in colony counts between the groups, and Dunn's post hoc test was used for multiple comparisons. All techniques and irrigation regimens significantly reduced the number of bacterial cells in the root canal (P < 0.001). Comparisons amongst the groups revealed significant differences between group 1A (sterile phosphate-buffered saline + Self-adjusting file)/group 1B (5% sodium hypochlorite + 15% EDTA + Self-adjusting file) (P = 0.031), group 1A (sterile phosphate-buffered saline + Self-adjusting file)/group 2C (5% sodium hypochlorite + 7% maleic acid + Reciproc) (P = 0.003), group 2A (sterile phosphate-buffered saline + Reciproc)/group 3B (5% sodium hypochlorite + 15% EDTA + ProTaper) (P = 0.036), group 3B (5% sodium hypochlorite + 15% EDTA + ProTaper)/group 1A (sterile phosphate-buffered saline + Self-adjusting file) (P < 0.001), and group 3C (5% sodium hypochlorite + 7% maleic acid + ProTaper)/group 1A (sterile phosphate-buffered saline + Self-adjusting file) (P = 0.033). No significant differences in terms of reduction in microbial counts were observed between single-file techniques (SAF and Reciproc) and serial Ni-Ti instrumentation technique (ProTaper) in combination with irrigants. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Nucleotide exchange and excision technology DNA shuffling and directed evolution.
Speck, Janina; Stebel, Sabine C; Arndt, Katja M; Müller, Kristian M
2011-01-01
Remarkable success in optimizing complex properties within DNA and proteins has been achieved by directed evolution. In contrast to various random mutagenesis methods and high-throughput selection methods, the number of available DNA shuffling procedures is limited, and protocols are often difficult to adjust. The strength of the nucleotide exchange and excision technology (NExT) DNA shuffling described here is the robust, efficient, and easily controllable DNA fragmentation step based on random incorporation of the so-called 'exchange nucleotides' by PCR. The exchange nucleotides are removed enzymatically, followed by chemical cleavage of the DNA backbone. The oligonucleotide pool is reassembled into full-length genes by internal primer extension, and the recombined gene library is amplified by standard PCR. The technique has been demonstrated by shuffling a defined gene library of chloramphenicol acetyltransferase variants using uridine as fragmentation defining exchange nucleotide. Substituting 33% of the dTTP with dUTP in the incorporation PCR resulted in shuffled clones with an average parental fragment size of 86 bases and revealed a mutation rate of only 0.1%. Additionally, a computer program (NExTProg) has been developed that predicts the fragment size distribution depending on the relative amount of the exchange nucleotide.
Theory and optical design of x-ray echo spectrometers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shvyd'ko, Yuri
X-ray echo spectroscopy, a space-domain counterpart of neutron spin echo, is a recently proposed inelastic x-ray scattering (IXS) technique. X-ray echo spectroscopy relies on imaging IXS spectra and does not require x-ray monochromatization. Due to this, the echo-type IXS spectrometers are broadband, and thus have a potential to simultaneously provide dramatically increased signal strength, reduced measurement times, and higher resolution compared to the traditional narrow-band scanning-type IXS spectrometers. The theory of x-ray echo spectrometers presented earlier [Yu. Shvyd'ko, Phys. Rev. Lett. 116, 080801 (2016)] is developed here further with a focus on questions of practical importance, which could facilitate opticalmore » design and assessment of the feasibility and performance of the echo spectrometers. Among others, the following questions are addressed: spectral resolution, refocusing condition, echo spectrometer tolerances, refocusing condition adjustment, effective beam size on the sample, spectral window of imaging and scanning range, impact of the secondary source size on the spectral resolution, angular dispersive optics, focusing and collimating optics, and detector's spatial resolution. In conclusion, examples of optical designs and characteristics of echo spectrometers with 1-meV and 0.1-meV resolutions are presented.« less
NASA Astrophysics Data System (ADS)
Huang, Yu
Solar energy becomes one of the major alternative renewable energy options for its huge abundance and accessibility. Due to the intermittent nature, the high demand of Maximum Power Point Tracking (MPPT) techniques exists when a Photovoltaic (PV) system is used to extract energy from the sunlight. This thesis proposed an advanced Perturbation and Observation (P&O) algorithm aiming for relatively practical circumstances. Firstly, a practical PV system model is studied with determining the series and shunt resistances which are neglected in some research. Moreover, in this proposed algorithm, the duty ratio of a boost DC-DC converter is the object of the perturbation deploying input impedance conversion to achieve working voltage adjustment. Based on the control strategy, the adaptive duty ratio step size P&O algorithm is proposed with major modifications made for sharp insolation change as well as low insolation scenarios. Matlab/Simulink simulation for PV model, boost converter control strategy and various MPPT process is conducted step by step. The proposed adaptive P&O algorithm is validated by the simulation results and detail analysis of sharp insolation changes, low insolation condition and continuous insolation variation.
Theory and optical design of x-ray echo spectrometers
Shvyd'ko, Yuri
2017-08-02
X-ray echo spectroscopy, a space-domain counterpart of neutron spin echo, is a recently proposed inelastic x-ray scattering (IXS) technique. X-ray echo spectroscopy relies on imaging IXS spectra and does not require x-ray monochromatization. Due to this, the echo-type IXS spectrometers are broadband, and thus have a potential to simultaneously provide dramatically increased signal strength, reduced measurement times, and higher resolution compared to the traditional narrow-band scanning-type IXS spectrometers. The theory of x-ray echo spectrometers presented earlier [Yu. Shvyd'ko, Phys. Rev. Lett. 116, 080801 (2016)] is developed here further with a focus on questions of practical importance, which could facilitate opticalmore » design and assessment of the feasibility and performance of the echo spectrometers. Among others, the following questions are addressed: spectral resolution, refocusing condition, echo spectrometer tolerances, refocusing condition adjustment, effective beam size on the sample, spectral window of imaging and scanning range, impact of the secondary source size on the spectral resolution, angular dispersive optics, focusing and collimating optics, and detector's spatial resolution. In conclusion, examples of optical designs and characteristics of echo spectrometers with 1-meV and 0.1-meV resolutions are presented.« less
Fixed-Base Comb with Window-Non-Adjacent Form (NAF) Method for Scalar Multiplication
Seo, Hwajeong; Kim, Hyunjin; Park, Taehwan; Lee, Yeoncheol; Liu, Zhe; Kim, Howon
2013-01-01
Elliptic curve cryptography (ECC) is one of the most promising public-key techniques in terms of short key size and various crypto protocols. For this reason, many studies on the implementation of ECC on resource-constrained devices within a practical execution time have been conducted. To this end, we must focus on scalar multiplication, which is the most expensive operation in ECC. A number of studies have proposed pre-computation and advanced scalar multiplication using a non-adjacent form (NAF) representation, and more sophisticated approaches have employed a width-w NAF representation and a modified pre-computation table. In this paper, we propose a new pre-computation method in which zero occurrences are much more frequent than in previous methods. This method can be applied to ordinary group scalar multiplication, but it requires large pre-computation table, so we combined the previous method with ours for practical purposes. This novel structure establishes a new feature that adjusts speed performance and table size finely, so we can customize the pre-computation table for our own purposes. Finally, we can establish a customized look-up table for embedded microprocessors. PMID:23881143
NASA Astrophysics Data System (ADS)
Xu, Bing; Du, Wen-Qiang; Li, Jia-Wen; Hu, Yan-Lei; Yang, Liang; Zhang, Chen-Chu; Li, Guo-Qiang; Lao, Zhao-Xin; Ni, Jin-Cheng; Chu, Jia-Ru; Wu, Dong; Liu, Su-Ling; Sugioka, Koji
2016-01-01
High efficiency fabrication and integration of three-dimension (3D) functional devices in Lab-on-a-chip systems are crucial for microfluidic applications. Here, a spatial light modulator (SLM)-based multifoci parallel femtosecond laser scanning technology was proposed to integrate microstructures inside a given ‘Y’ shape microchannel. The key novelty of our approach lies on rapidly integrating 3D microdevices inside a microchip for the first time, which significantly reduces the fabrication time. The high quality integration of various 2D-3D microstructures was ensured by quantitatively optimizing the experimental conditions including prebaking time, laser power and developing time. To verify the designable and versatile capability of this method for integrating functional 3D microdevices in microchannel, a series of microfilters with adjustable pore sizes from 12.2 μm to 6.7 μm were fabricated to demonstrate selective filtering of the polystyrene (PS) particles and cancer cells with different sizes. The filter can be cleaned by reversing the flow and reused for many times. This technology will advance the fabrication technique of 3D integrated microfluidic and optofluidic chips.
Reconstruction of sparse-view X-ray computed tomography using adaptive iterative algorithms.
Liu, Li; Lin, Weikai; Jin, Mingwu
2015-01-01
In this paper, we propose two reconstruction algorithms for sparse-view X-ray computed tomography (CT). Treating the reconstruction problems as data fidelity constrained total variation (TV) minimization, both algorithms adapt the alternate two-stage strategy: projection onto convex sets (POCS) for data fidelity and non-negativity constraints and steepest descent for TV minimization. The novelty of this work is to determine iterative parameters automatically from data, thus avoiding tedious manual parameter tuning. In TV minimization, the step sizes of steepest descent are adaptively adjusted according to the difference from POCS update in either the projection domain or the image domain, while the step size of algebraic reconstruction technique (ART) in POCS is determined based on the data noise level. In addition, projection errors are used to compare with the error bound to decide whether to perform ART so as to reduce computational costs. The performance of the proposed methods is studied and evaluated using both simulated and physical phantom data. Our methods with automatic parameter tuning achieve similar, if not better, reconstruction performance compared to a representative two-stage algorithm. Copyright © 2014 Elsevier Ltd. All rights reserved.
Body size-adjusted dose analysis of pirfenidone in patients with interstitial pneumonia.
Uehara, Masahiro; Enomoto, Noriyuki; Oyama, Yoshiyuki; Suzuki, Yuzo; Kono, Masato; Furuhashi, Kazuki; Fujisawa, Tomoyuki; Inui, Naoki; Nakamura, Yutaro; Suda, Takafumi
2018-03-01
Pirfenidone is an effective anti-fibrotic agent for idiopathic pulmonary fibrosis (IPF). Although adverse events (AE) sometimes prevent patients from continuing treatment, current dose adjustment guidance does not consider patient body size or weight (BW). The aim of this study was to evaluate the importance of pirfenidone dose adjustment by body surface area (BSA) or BW for preventing AE and permitting continuous treatment in patients with interstitial pneumonia (IP). Sixty-seven Japanese patients with IP including 46 patients with IPF treated with pirfenidone between 2009 and 2015 were retrospectively evaluated. Pirfenidone doses were adjusted by BSA or BW and were compared with clinical parameters. Forty-two of 67 patients (62.7%) with IP showed AE, most commonly gastrointestinal symptoms (77.5%). Patients having AE received significantly higher adjusted doses of pirfenidone by both BSA and BW (P = 0.024 and P = 0.010, respectively), while unadjusted doses did not differ. BSA-adjusted dose discriminated patients with AE from those without (area under the curve = 0.666 at 1085 mg/m 2 ). Six of seven patients (85.7%) who discontinued pirfenidone due to AE took ≥1085 mg/m 2 of pirfenidone. In a subgroup with IPF, patients taking a medium dose (median: 876 median-1085 mg/m 2 ) showed a lower annual decline in % forced vital capacity than patients taking a lower dose (P = 0.025). BSA-adjusted pirfenidone dosing may be useful to prevent AE whilst achieving a long-term treatment effect in patients with IP. © 2017 Asian Pacific Society of Respirology.
Advanced illumination control algorithm for medical endoscopy applications
NASA Astrophysics Data System (ADS)
Sousa, Ricardo M.; Wäny, Martin; Santos, Pedro; Morgado-Dias, F.
2015-05-01
CMOS image sensor manufacturer, AWAIBA, is providing the world's smallest digital camera modules to the world market for minimally invasive surgery and one time use endoscopic equipment. Based on the world's smallest digital camera head and the evaluation board provided to it, the aim of this paper is to demonstrate an advanced fast response dynamic control algorithm of the illumination LED source coupled to the camera head, over the LED drivers embedded on the evaluation board. Cost efficient and small size endoscopic camera modules nowadays embed minimal size image sensors capable of not only adjusting gain and exposure time but also LED illumination with adjustable illumination power. The LED illumination power has to be dynamically adjusted while navigating the endoscope over changing illumination conditions of several orders of magnitude within fractions of the second to guarantee a smooth viewing experience. The algorithm is centered on the pixel analysis of selected ROIs enabling it to dynamically adjust the illumination intensity based on the measured pixel saturation level. The control core was developed in VHDL and tested in a laboratory environment over changing light conditions. The obtained results show that it is capable of achieving correction speeds under 1 s while maintaining a static error below 3% relative to the total number of pixels on the image. The result of this work will allow the integration of millimeter sized high brightness LED sources on minimal form factor cameras enabling its use in endoscopic surgical robotic or micro invasive surgery.
NASA Technical Reports Server (NTRS)
Chai, Dean; Queen, Steve; Placanica, Sam
2015-01-01
NASA's Magnetospheric Multi-Scale (MMS) mission successfully launched on March 13, 2015 (UTC) consists of four identically instrumented spin-stabilized observatories that function as a constellation to study magnetic reconnection in space. The need to maintain sufficiently accurate spatial and temporal formation resolution of the observatories must be balanced against the logistical constraints of executing overly-frequent maneuvers on a small fleet of spacecraft. These two considerations make for an extremely challenging maneuver design problem. This paper focuses on the design elements of a 6-DOF spacecraft attitude control and maneuvering system capable of delivering the high-precision adjustments required by the constellation designers---specifically, the design, implementation, and on-orbit performance of the closed-loop formation-class maneuvers that include initialization, maintenance, and re-sizing. The maneuvering control system flown on MMS utilizes a micro-gravity resolution accelerometer sampled at a high rate in order to achieve closed-loop velocity tracking of an inertial target with arc-minute directional and millimeter-per-second magnitude accuracy. This paper summarizes the techniques used for correcting bias drift, sensor-head offsets, and centripetal aliasing in the acceleration measurements. It also discusses the on-board pre-maneuver calibration and compensation algorithms as well as the implementation of the post-maneuver attitude adjustments.
NASA Technical Reports Server (NTRS)
Chai, Dean J.; Queen, Steven Z.; Placanica, Samuel J.
2015-01-01
NASAs Magnetospheric Multiscale (MMS) mission successfully launched on March 13,2015 (UTC) consists of four identically instrumented spin-stabilized observatories that function as a constellation to study magnetic reconnection in space. The need to maintain sufficiently accurate spatial and temporal formation resolution of the observatories must be balanced against the logistical constraints of executing overly-frequent maneuvers on a small fleet of spacecraft. These two considerations make for an extremely challenging maneuver design problem. This paper focuses on the design elements of a 6-DOF spacecraft attitude control and maneuvering system capable of delivering the high-precision adjustments required by the constellation designers specifically, the design, implementation, and on-orbit performance of the closed-loop formation-class maneuvers that include initialization, maintenance, and re-sizing. The maneuvering control system flown on MMS utilizes a micro-gravity resolution accelerometer sampled at a high rate in order to achieve closed-loop velocity tracking of an inertial target with arc-minute directional and millimeter-per second magnitude accuracy. This paper summarizes the techniques used for correcting bias drift, sensor-head offsets, and centripetal aliasing in the acceleration measurements. It also discusses the on-board pre-maneuver calibration and compensation algorithms as well as the implementation of the post-maneuver attitude adjustments.
Speckless head-up display on two spatial light modulators
NASA Astrophysics Data System (ADS)
Siemion, Andrzej; Ducin, Izabela; Kakarenko, Karol; Makowski, Michał; Siemion, Agnieszka; Suszek, Jarosław; Sypek, Maciej; Wojnowski, Dariusz; Jaroszewicz, Zbigniew; Kołodziejczyk, Andrzej
2010-12-01
There is a continuous demand for the computer generated holograms to give an almost perfect reconstruction with a reasonable cost of manufacturing. One method of improving the image quality is to illuminate a Fourier hologram with a quasi-random, but well known, light field phase distribution. It can be achieved with a lithographically produced phase mask. Up to date, the implementation of the lithographic technique is relatively complex and time and money consuming, which is why we have decided to use two Spatial Light Modulators (SLM). For the correctly adjusted light polarization a SLM acts as a pure phase modulator with 256 adjustable phase levels between 0 and 2π. The two modulators give us an opportunity to use the whole surface of the device and to reduce the size of the experimental system. The optical system with one SLM can also be used but it requires dividing the active surface into halves (one for the Fourier hologram and the second for the quasi-random diffuser), which implies a more complicated optical setup. A larger surface allows to display three Fourier holograms, each for one primary colour: red, green and blue. This allows to reconstruct almost noiseless colourful dynamic images. In this work we present the results of numerical simulations of image reconstructions with the use of two SLM displays.
Hughes, Laura A. E.; Simons, Colinda C. J. M.; van den Brandt, Piet A.; Goldbohm, R. Alexandra; de Goeij, Anton F.; de Bruïne, Adriaan P.; van Engeland, Manon; Weijenberg, Matty P.
2011-01-01
Background We investigated how body size and physical activity influence the risk of the CpG island methylator phenotype (CIMP) in colorectal cancer (CRC). Methods In the Netherlands Cohort Study (n = 120,852), risk factors were self-reported at baseline in 1986. After 7.3 years of follow-up, 603 cases and 4,631 sub-cohort members were available. CIMP status according to the Weisenberger markers was determined using methylation specific PCR on DNA from paraffin embedded tumor tissue. Hazard rate ratios (HR) and 95% confidence intervals for CIMP (27.7%) and non-CIMP (72.3%) tumors were calculated according to BMI, BMI at age 20, BMI change, trouser/skirt size, height, and physical activity. Results BMI modeled per 5 kg/m2 increase was associated with both CIMP and non-CIMP tumors, however, HRs were attenuated when additionally adjusted for trouser/skirt size. Trouser/skirt size, per 2 size increase, was associated with both tumor subtypes, even after adjustment for BMI (CIMP HR: 1.20, 95%CI: 1.01–1.43; non-CIMP HR: 1.14, 95%CI: 1.04–1.28). Height per 5 cm was associated with both tumor sub-types, but HRs were attenuated when adjusted for body weight. BMI at age 20 was positively associated with increased risk of CIMP tumors and the association was significantly less pronounced for non-CIMP tumors (P-heterogeneity = 0.01). Physical activity was inversely associated with both subtypes, but a dose-response association was observed only for non-CIMP tumors (P-trend = 0.02). Conclusions Body size, especially central adiposity, may increase the risk of both CIMP and non-CIMP tumors. Body fat at young age may differentially influence risk. Physical activity appears to decrease the risk of CRC regardless of these molecular subtypes. PMID:21483668
Hughes, Laura A E; Simons, Colinda C J M; van den Brandt, Piet A; Goldbohm, R Alexandra; de Goeij, Anton F; de Bruïne, Adriaan P; van Engeland, Manon; Weijenberg, Matty P
2011-04-05
We investigated how body size and physical activity influence the risk of the CpG island methylator phenotype (CIMP) in colorectal cancer (CRC). In the Netherlands Cohort Study (n = 120,852), risk factors were self-reported at baseline in 1986. After 7.3 years of follow-up, 603 cases and 4,631 sub-cohort members were available. CIMP status according to the Weisenberger markers was determined using methylation specific PCR on DNA from paraffin embedded tumor tissue. Hazard rate ratios (HR) and 95% confidence intervals for CIMP (27.7%) and non-CIMP (72.3%) tumors were calculated according to BMI, BMI at age 20, BMI change, trouser/skirt size, height, and physical activity. BMI modeled per 5 kg/m(2) increase was associated with both CIMP and non-CIMP tumors, however, HRs were attenuated when additionally adjusted for trouser/skirt size. Trouser/skirt size, per 2 size increase, was associated with both tumor subtypes, even after adjustment for BMI (CIMP HR: 1.20, 95%CI: 1.01-1.43; non-CIMP HR: 1.14, 95%CI: 1.04-1.28). Height per 5 cm was associated with both tumor sub-types, but HRs were attenuated when adjusted for body weight. BMI at age 20 was positively associated with increased risk of CIMP tumors and the association was significantly less pronounced for non-CIMP tumors (P-heterogeneity = 0.01). Physical activity was inversely associated with both subtypes, but a dose-response association was observed only for non-CIMP tumors (P-trend = 0.02). Body size, especially central adiposity, may increase the risk of both CIMP and non-CIMP tumors. Body fat at young age may differentially influence risk. Physical activity appears to decrease the risk of CRC regardless of these molecular subtypes.
Projecting School Psychology Staffing Needs Using a Risk-Adjusted Model.
ERIC Educational Resources Information Center
Stellwagen, Kurt
A model is proposed to project optimal school psychology service ratios based upon the percentages of at risk students enrolled within a given school population. Using the standard 1:1,000 service ratio advocated by The National Association of School Psychologists (NASP) as a starting point, ratios are then adjusted based upon the size of three…
A self-adjusting expandable GPS collar for male elk
Brian L. Dick; Scott L. Findholt; Bruce K. Johnson
2013-01-01
It is a challenge to use collars on male cervids because their neck size can increase substantially during the rut and also because of growth as the animal matures. We describe how to build a self-adjusting expandable collar for yearling or adult male Rocky Mountain elk (Cervus elaphus) to which very high frequency transmitters and global...
Coherent Power Analysis in Multi-Level Studies Using Design Parameters from Surveys
ERIC Educational Resources Information Center
Rhoads, Christopher
2016-01-01
Current practice for conducting power analyses in hierarchical trials using survey based ICC and effect size estimates may be misestimating power because ICCs are not being adjusted to account for treatment effect heterogeneity. Results presented in Table 1 show that the necessary adjustments can be quite large or quite small. Furthermore, power…
What's in a Grade? A Professor's Guide to Adjusting Scores on Student Assessments
ERIC Educational Resources Information Center
Kuhlthau, Kaitlin; Ruscio, John; Luce, Christine; Furey, Matthew
2017-01-01
Grades serve many important purposes, and educators agree it is important to assign them accurately and fairly. Interviews with 100 professors across a broad range of academic disciplines at a mid-sized state college revealed little consensus on whether, when, or how to adjust scores when assigning grades. Their responses informed a review of…
In Vivo Single-Cell Fluorescence and Size Scaling of Phytoplankton Chlorophyll Content.
Álvarez, Eva; Nogueira, Enrique; López-Urrutia, Ángel
2017-04-01
In unicellular phytoplankton, the size scaling exponent of chlorophyll content per cell decreases with increasing light limitation. Empirical studies have explored this allometry by combining data from several species, using average values of pigment content and cell size for each species. The resulting allometry thus includes phylogenetic and size scaling effects. The possibility of measuring single-cell fluorescence with imaging-in-flow cytometry devices allows the study of the size scaling of chlorophyll content at both the inter- and intraspecific levels. In this work, the changing allometry of chlorophyll content was estimated for the first time for single phytoplankton populations by using data from a series of incubations with monocultures exposed to different light levels. Interspecifically, our experiments confirm previous modeling and experimental results of increasing size scaling exponents with increasing irradiance. A similar pattern was observed intraspecifically but with a larger variability in size scaling exponents. Our results show that size-based processes and geometrical approaches explain variations in chlorophyll content. We also show that the single-cell fluorescence measurements provided by imaging-in-flow devices can be applied to field samples to understand the changes in the size dependence of chlorophyll content in response to environmental variables affecting primary production. IMPORTANCE The chlorophyll concentrations in phytoplankton register physiological adjustments in cellular pigmentation arising mainly from changes in light conditions. The extent of these adjustments is constrained by the size of the phytoplankton cells, even within single populations. Hence, variations in community chlorophyll derived from photoacclimation are also dependent on the phytoplankton size distribution. Copyright © 2017 American Society for Microbiology.
In Vivo Single-Cell Fluorescence and Size Scaling of Phytoplankton Chlorophyll Content
Nogueira, Enrique; López-Urrutia, Ángel
2017-01-01
ABSTRACT In unicellular phytoplankton, the size scaling exponent of chlorophyll content per cell decreases with increasing light limitation. Empirical studies have explored this allometry by combining data from several species, using average values of pigment content and cell size for each species. The resulting allometry thus includes phylogenetic and size scaling effects. The possibility of measuring single-cell fluorescence with imaging-in-flow cytometry devices allows the study of the size scaling of chlorophyll content at both the inter- and intraspecific levels. In this work, the changing allometry of chlorophyll content was estimated for the first time for single phytoplankton populations by using data from a series of incubations with monocultures exposed to different light levels. Interspecifically, our experiments confirm previous modeling and experimental results of increasing size scaling exponents with increasing irradiance. A similar pattern was observed intraspecifically but with a larger variability in size scaling exponents. Our results show that size-based processes and geometrical approaches explain variations in chlorophyll content. We also show that the single-cell fluorescence measurements provided by imaging-in-flow devices can be applied to field samples to understand the changes in the size dependence of chlorophyll content in response to environmental variables affecting primary production. IMPORTANCE The chlorophyll concentrations in phytoplankton register physiological adjustments in cellular pigmentation arising mainly from changes in light conditions. The extent of these adjustments is constrained by the size of the phytoplankton cells, even within single populations. Hence, variations in community chlorophyll derived from photoacclimation are also dependent on the phytoplankton size distribution. PMID:28115378
Intraspecific variation in egg size and egg composition in birds: effects on offspring fitness.
Williams, T D
1994-02-01
1. There is little unequivocal evidence to date in support of a positive relationship between egg size and offspring fitness in birds. Although 40 studies (of 34 species) have considered the effect of variation in egg size on chick growth and/or survival up to fledgling only 12 studies have controlled for other characters potentially correlated both with egg size and offspring fitness. Of these only two have reported a significant residual effect of egg size on chick growth (in the roseate tern and European blackbird) and three a residual effect on chick survival (all in seabirds: common tern, lesser black-backed gull and kittiwake). 2. More consistent evidence exists, though from fewer studies, for a positive relationship between egg size and offspring fitness early in the chick-rearing period; chick growth and chick survival being dependent on egg size in 8 of 10 studies and 4 of 5 studies respectively. It is suggested that the most important effect of variation in egg size might be in determining the probability of offspring survival in the first few days after hatching. 3. Egg size explains on average 66% of the variation in chick mass at hatching (n = 35 studies) but only 30% of the variation in chick body size (n = 18). When effects of hatching body size are controlled for chick mass remains significantly correlated with egg size, though the reverse is not true. This supports the hypothesis that large eggs give rise to heavier chicks at hatching, i.e., chicks with more nutrient (yolk) reserves, rather than structurally larger chicks. 4. Egg composition increased isometrically with increasing egg size in about half the studies so far reported (n equals approximately 20). However, in seabirds, and some passerines, larger eggs contain disproportionately more albumen, whilst in some waterfowl percentage yolk content increases with increasing egg size. Changes in albumen content largely reflect variation in the water content of eggs, but changes in yolk content involve variation in lipid content, and therefore in egg 'quality.' The adaptive significance of variation in egg composition is considered; females may adjust egg composition facultatively to maximise the benefits to their offspring of increased reproductive investment. 5. Considerations for future research are discussed with particular emphasis on experimental studies and the application of new techniques.
Hilgard, Joseph; Engelhardt, Christopher R; Rouder, Jeffrey N
2017-07-01
Violent video games are theorized to be a significant cause of aggressive thoughts, feelings, and behaviors. Important evidence for this claim comes from a large meta-analysis by Anderson and colleagues (2010), who found effects of violent games in experimental, cross-sectional, and longitudinal research. In that meta-analysis, the authors argued that there is little publication or analytic bias in the literature, an argument supported by their use of the trim-and-fill procedure. In the present manuscript, we reexamine their meta-analysis using a wider array of techniques for detecting bias and adjusting effect sizes. Our conclusions differ from those of Anderson and colleagues in 3 salient ways. First, we detect substantial publication bias in experimental research on the effects of violent games on aggressive affect and aggressive behavior. Second, after adjustment for bias, the effects of violent games on aggressive behavior in experimental research are estimated as being very small, and estimates of effects on aggressive affect are much reduced. In contrast, the cross-sectional literature finds correlations that appear largely unbiased. Third, experiments meeting the original authors' criteria for methodological quality do not yield larger adjusted effects than other experiments, but instead yield larger indications of bias, indicating that perhaps they were selected for significance. We outline future directions for stronger experimental research. The results indicate the need for an open, transparent, and preregistered research process to test the existence of the basic phenomenon. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Miller, Timothy; Lau, Tsz; Vasan, Rohit; Danner, Christopher; Youssef, A Samy; van Loveren, Harry; Agazzi, Siviero
2014-06-01
Stereotactic radiosurgery is generally accepted as one of the best treatment options for vestibular schwannomas. We question whether growth control is an accurate measure of success in vestibular schwannoma treatment. We aim to clarify the success rate of stereotactic radiosurgery and adjust the reported results to the benign natural history of untreated tumors. All articles were taken from a PubMed search of the English literature from the years 2000-2011. Inclusion criteria were articles containing the number of patients treated, radiation technique, average tumor size, follow-up time, and percentage of tumors growing during follow-up. Data were extracted from 19 articles. Success rates were adjusted using published data that 17% to 30% of vestibular schwannomas grow. The average reported success rate for stereotactic radiosurgery across all articles was 95.5%. When considering 17% or 30% natural growth without intervention, the adjusted success rates became 78.2% and 86.9% respectively. These rates were obtained by applying the natural history growth percentages to any tumors not reported to be growing before radiosurgical intervention. Success in the treatment of vestibular schwannomas with stereotactic radiosurgery is often defined as lack of further growth. Recent data on the natural growth history of vestibular schwannomas raise the question of whether this is the best definition of success. We have identified a lack of continuity regarding the reporting of success and emphasize the importance of the clarification of the success of radiosurgery to make informed decisions regarding the best treatment options for vestibular schwannoma. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Fibrianto, K.; Febryana, Y. R.; Wulandari, E. S.
2018-03-01
This study aimed to assess the effect of different brewing techniques with the use of appropriate particle size standard of Apresiocoffee cafe (Category 1) compared to the difference brewing techniques with the use of the same particle size (coarse) (Category 2) of the sensory attributes Dampit robusta coffee. Rate-All-That-Apply (RATA) method was applied in this study, and the data was analysed by ANOVA General Linier Model (GLM) on Minitab-16. The influence of brewing techniques (tubruk, French-press, drips, syphon) and type of particle size ground coffee (fine, medium, coarse) were sensorially observed. The result showed that only two attributes, including bitter taste, and astringent/rough-mouth-feel were affected by brewing techniques (p-value <0.05) as observed for brewed coarse coffee powder.
Family Medicine Panel Size with Care Teams: Impact on Quality.
Angstman, Kurt B; Horn, Jennifer L; Bernard, Matthew E; Kresin, Molly M; Klavetter, Eric W; Maxson, Julie; Willis, Floyd B; Grover, Michael L; Bryan, Michael J; Thacher, Tom D
2016-01-01
The demand for comprehensive primary health care continues to expand. The development of team-based practice allows for improved capacity within a collective, collaborative environment. Our hypothesis was to determine the relationship between panel size and access, quality, patient satisfaction, and cost in a large family medicine group practice using a team-based care model. Data were retrospectively collected from 36 family physicians and included total panel size of patients, percentage of time spent on patient care, cost of care, access metrics, diabetic quality metrics, patient satisfaction surveys, and patient care complexity scores. We used linear regression analysis to assess the relationship between adjusted physician panel size, panel complexity, and outcomes. The third available appointments (P < .01) and diabetic quality (P = .03) were negatively affected by increased panel size. Patient satisfaction, cost, and percentage fill rate were not affected by panel size. A physician-adjusted panel size larger than the current mean (2959 patients) was associated with a greater likelihood of poor-quality rankings (≤25th percentile) compared with those with a less than average panel size (odds ratio [OR], 7.61; 95% confidence interval [CI], 1.13-51.46). Increased panel size was associated with a longer time to the third available appointment (OR, 10.9; 95% CI, 1.36-87.26) compared with physicians with panel sizes smaller than the mean. We demonstrated a negative impact of larger panel size on diabetic quality results and available appointment access. Evaluation of a family medicine practice parameters while controlling for panel size and patient complexity may help determine the optimal panel size for a practice. © Copyright 2016 by the American Board of Family Medicine.
The influence of mineral dust particles on the energy output of photovoltaic cells
NASA Astrophysics Data System (ADS)
Roesch, C.; Eltahir, E. A. B.; Al-awwad, Z.; Alqatari, S.; Cziczo, D. J.; Roesch, M.
2016-12-01
The city of Al Khafji in Saudi Arabia plans to provide a regular supply of desalinated water from the Persian Gulf while simultaneously cutting back on the usage of fossil fuels. The power for the high energy-consuming reverse osmosis (RO) process will be derived from photovoltaic (PV) cells as a cleaner and resource-conserving means of energy production. Numerous sun hours (yearly 3000) makes the Persian Gulf region's geographical location appropriate for applying PV techniques at this scale. A major concern for PV power generation is mineral dust from desert regions accumulating on surfaces and thereby reducing the energy output. This study aims to show the impact of dust particles on the PV energy reduction by examining dust samples from various Persian Gulf regions. Bulk samples were collected at the surface. The experimental setup involved a sealed container with a solar panel unit (SPU), including an adjustable mounting plate, solar cells (amorphous and monocrystalline), and a pyranometer (SMP3, Kipp & Zonen Inc.). A Tungsten Halogen lamp was used as the light source. Dust particles were aerosolized with a shaker (Multi-Wrist shaker, Lab line). Different techniques were applied to characterize each sample: the particle size distributions were measured using an Optical Particle Sizer (OPS, TSI Inc.), the chemical composition was analyzed using the Particle Analysis by Mass Spectrometry (PALMS) instrument, and Transmission Electron Microscope Energy-Dispersive X-ray spectroscopy (TEM-EDX) was used to define morphology, size and structure. Preliminary results show that the energy output is affected by aerosol morphology (monodisperse, polydisperse), composition and solar cell type.
Concept for tremor compensation for a handheld OCT-laryngoscope
NASA Astrophysics Data System (ADS)
Donner, Sabine; Deutsch, Stefanie; Bleeker, Sebastian; Ripken, Tammo; Krüger, Alexander
2013-06-01
Optical coherence tomography (OCT) is a non-invasive imaging technique which can create optical tissue sections, enabling diagnosis of vocal cord tissue. To take full advantage from the non-contact imaging technique, OCT was adapted to an indirect laryngoscope to work on awake patients. Using OCT in a handheld diagnostic device the challenges of rapid working distance adjustment and tracking of axial motion arise. The optical focus of the endoscopic sample arm and the reference-arm length can be adjusted in a range of 40 mm to 90 mm. Automatic working distance adjustment is based on image analysis of OCT B-scans which identifies off depth images as well as position errors. The movable focal plane and reference plane are used to adjust working distance to match the sample depth and stabilise the sample in the desired axial position of the OCT scans. The autofocus adjusts the working distance within maximum 2.7 seconds for the maximum initial displacement of 40 mm. The amplitude of hand tremor during 60 s handheld scanning was reduced to 50 % and it was shown that the image stabilisation keeps the position error below 0.5 mm. Fast automatic working distance adjustment is crucial to minimise the duration of the diagnostic procedure. The image stabilisation compensates relative axial movements during handheld scanning.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wetzel, D.; Shi, Y; Reffner, J
This reports the first detection of chemical heterogeneity in octenyl succinic anhydride modified single starch granules using a Fourier transform infrared (FT-IR) microspectroscopical technique that combines diffraction-limited infrared microspectroscopy with a step size that is less than the mask projected spot size focused on the plane of the sample. The high spatial resolution was achieved with the combination of the application of a synchrotron infrared source and the confocal image plane masking system of the double-pass single-mask Continuum{reg_sign} infrared microscope. Starch from grains such as corn and wheat exists in granules. The size of the granules depends on the plantmore » producing the starch. Granules used in this study typically had a median size of 15 {micro}m. In the production of modified starch, an acid anhydride typically is reacted with OH groups of the starch polymer. The resulting esterification adds the ester carbonyl (1723 cm{sup -1}) organic functional group to the polymer and the hydrocarbon chain of the ester contributes to the CH{sub 2} stretching vibration to enhance the intensity of the 2927 cm{sup -1} band. Detection of the relative modifying population on a single granule was accomplished by ratioing the baseline adjusted peak area of the carbonyl functional group to that of a carbohydrate band. By stepping a confocally defined infrared beam as small as 5 {micro}m x 5 {micro}m across a starch granule 1 {micro}m at a time in both the x and y directions, the heterogeneity is detected with the highest possible spatial resolution.« less
Kim, Hyo Jin; Lee, Joongyub; Park, Miseon; Kim, Yuri; Lee, Hajeong; Kim, Dong Ki; Joo, Kwon Wook; Kim, Yon Su; Cho, Eun Jin; Ahn, Curie
2017-01-01
Background Lower education level could be a risk factor for higher peritoneal dialysis (PD)-associated peritonitis, potentially resulting in technique failure. This study evaluated the influence of lower education level on the development of peritonitis, technique failure, and overall mortality. Methods Patients over 18 years of age who started PD at Seoul National University Hospital between 2000 and 2012 with information on the academic background were enrolled. Patients were divided into three groups: middle school or lower (academic year≤9, n = 102), high school (9
Kim, Hyo Jin; Lee, Joongyub; Park, Miseon; Kim, Yuri; Lee, Hajeong; Kim, Dong Ki; Joo, Kwon Wook; Kim, Yon Su; Cho, Eun Jin; Ahn, Curie; Oh, Kook-Hwan
2017-01-01
Lower education level could be a risk factor for higher peritoneal dialysis (PD)-associated peritonitis, potentially resulting in technique failure. This study evaluated the influence of lower education level on the development of peritonitis, technique failure, and overall mortality. Patients over 18 years of age who started PD at Seoul National University Hospital between 2000 and 2012 with information on the academic background were enrolled. Patients were divided into three groups: middle school or lower (academic year≤9, n = 102), high school (9
Harvey, Colin E; Laster, Larry; Shofer, Frances; Miller, Bonnie
2008-09-01
The development of a total mouth periodontal scoring system is described. This system uses methods to score the full extent of gingivitis and periodontitis of all tooth surfaces, weighted by size of teeth, and adjusted by size of dog.
Code of Federal Regulations, 2010 CFR
2010-10-01
... damaged by shark bites may be retained only if the length of the remainder of the fish is equal to or... after consideration of additional scientific information and fish measurement data, and will be made... otherwise adjusted. (e) Sharks. The following size limits change depending on the species being caught and...
Apollo experience report: Reliability and quality assurance
NASA Technical Reports Server (NTRS)
Sperber, K. P.
1973-01-01
The reliability of the Apollo spacecraft resulted from the application of proven reliability and quality techniques and from sound management, engineering, and manufacturing practices. Continual assessment of these techniques and practices was made during the program, and, when deficiencies were detected, adjustments were made and the deficiencies were effectively corrected. The most significant practices, deficiencies, adjustments, and experiences during the Apollo Program are described in this report. These experiences can be helpful in establishing an effective base on which to structure an efficient reliability and quality assurance effort for future space-flight programs.
NASA Astrophysics Data System (ADS)
Zhang, X.; Anagnostou, E. N.
2016-12-01
This research contributes to the improvement of high resolution satellite applications in tropical regions with mountainous topography. Such mountainous regions are usually covered by sparse networks of in-situ observations while quantitative precipitation estimation from satellite sensors exhibits strong underestimation of heavy orographically enhanced storm events. To address this issue, our research applies a satellite error correction technique based solely on high-resolution numerical weather predictions (NWP). Our previous work has demonstrated the accuracy of this method in two mid-latitude mountainous regions (Zhang et al. 2013*1, Zhang et al. 2016*2), while the current research focuses on a comprehensive evaluation in three topical mountainous regions: Colombia, Peru and Taiwan. In addition, two different satellite precipitation products, NOAA Climate Prediction Center morphing technique (CMORPH) and Precipitation Estimation from Remotely Sensed Information using Artificial Neural Networks-Cloud Classification System (PERSIANN-CCS), are considered. The study includes a large number of heavy precipitation events (68 events over the three regions) in the period 2004 to 2012. The NWP-based adjustments of the two satellite products are contrasted to their corresponding gauge-adjusted post-processing products. Preliminary results show that the NWP-based adjusted CMORPH product is consistently improved relative to both original and gauge-adjusted precipitation products for all regions and storms examined. The improvement of PERSIANN-CCS product is less significant and less consistent relative to the CMORPH performance improvements from the NWP-based adjustment. *1Zhang, Xinxuan, Emmanouil N. Anagnostou, Maria Frediani, Stavros Solomos, and George Kallos. "Using NWP simulations in satellite rainfall estimation of heavy precipitation events over mountainous areas." Journal of Hydrometeorology 14, no. 6 (2013): 1844-1858.*2 Zhang, Xinxuan, Emmanouil N. Anagnostou, and Humberto Vergara. "Hydrologic Evaluation of NWP-Adjusted CMORPH Estimates of Hurricane-Induced Precipitation in the Southern Appalachians." Journal of Hydrometeorology 17.4 (2016): 1087-1099.
Recent trends in particle size analysis techniques
NASA Technical Reports Server (NTRS)
Kang, S. H.
1984-01-01
Recent advances and developments in the particle-sizing technologies are briefly reviewed in accordance with three operating principles including particle size and shape descriptions. Significant trends of the particle size analysing equipment recently developed show that compact electronic circuitry and rapid data processing systems were mainly adopted in the instrument design. Some newly developed techniques characterizing the particulate system were also introduced.
NASA Astrophysics Data System (ADS)
Pirani, F.; Cappelletti, D.; Vecchiocattivi, F.; Vattuone, L.; Gerbi, A.; Rocca, M.; Valbusa, U.
2004-02-01
A light and compact mechanical velocity selector, of novel design, for applications in supersonic molecular-beam studies has been developed. It represents a simplified version of the traditional, 50 year old, slotted disks velocity selector. Taking advantage of new materials and improved machining techniques, the new version has been realized with only two rotating slotted disks, driven by an electrical motor with adjustable frequency of rotation, and thus has a much smaller weight and size with respect to the original design, which may allow easier implementation in most of the available molecular-beam apparatuses. This new type of selector, which maintains a sufficiently high velocity resolution, has been developed for sampling molecules with different degrees of rotational alignment, like those emerging from a seeded supersonic expansion. This sampling is the crucial step to realize new molecular-beam experiments to study the effect of molecular alignment in collisional processes.
Improving Efficiency in Multi-Strange Baryon Reconstruction in d-Au at STAR
NASA Astrophysics Data System (ADS)
Leight, William
2003-10-01
We report preliminary multi-strange baryon measurements for d-Au collisions recorded at RHIC by the STAR experiment. After using classical topological analysis, in which cuts for each discriminating variable are adjusted by hand, we investigate improvements in signal-to-noise optimization using Linear Discriminant Analysis (LDA). LDA is an algorithm for finding, in the n-dimensional space of the n discriminating variables, the axis on which the signal and noise distributions are most separated. LDA is the first step in moving towards more sophisticated techniques for signal-to-noise optimization, such as Artificial Neural Nets. Due to the relatively low background and sufficiently high yields of d-Au collisions, they form an ideal system to study these possibilities for improving reconstruction methods. Such improvements will be extremely important for forthcoming Au-Au runs in which the size of the combinatoric background is a major problem in reconstruction efforts.
NASA Astrophysics Data System (ADS)
Akbaba, Hasan; Karagöz, Uğur; Selamet, Yusuf; Kantarcı, A. Gülten
2017-03-01
The aim of this study was to develop a novel iron oxide nanoparticle synthesis method with in-situ surface coating. For this purpose multiple emulsions were used as microreactors for the first time and magnetic iron oxide particles synthesized in the core of cationic solid lipid nanoparticles. DLS, SEM, TEM, VSM, Raman Spectrometer, XRD, and XPS techniques were performed for characterization of the magnetic nanoparticles. Obtained magnetic nanoparticles are superparamagnetic and no additional process was needed for surface adjustments. They are positively charged as a result of cationic lipid coating and has appropriate particle size (<30 nm) for drug or nucleic acid delivery. Structure analysis showed that magnetic core material is in the form of magnetite. Saturation magnetization value was measured as 15-17 emu g-1 for lipid coated magnetic nanoparticles obtained by multiple emulsion method which is reasonably sufficient for magnetic targeting.
Laser-induced breakdown spectroscopy for detection of heavy metals in environmental samples
NASA Astrophysics Data System (ADS)
Wisbrun, Richard W.; Schechter, Israel; Niessner, Reinhard; Schroeder, Hartmut
1993-03-01
The application of LIBS technology as a sensor for heavy metals in solid environmental samples has been studied. This specific application introduces some new problems in the LIBS analysis. Some of them are related to the particular distribution of contaminants in the grained samples. Other problems are related to mechanical properties of the samples and to general matrix effects, like the water and organic fibers content of the sample. An attempt has been made to optimize the experimental set-up for the various involved parameters. The understanding of these factors has enabled the adjustment of the technique to the substrates of interest. The special importance of the grain size and of the laser-induced aerosol production is pointed out. Calibration plots for the analysis of heavy metals in diverse sand and soil samples have been carried out. The detection limits are shown to be usually below the recent regulation restricted concentrations.
Methyl-modified silica nanobowl for 2D self-organized nanostructure with hydrophobic performance.
Chen, Lingling; Sun, Aihua; Wang, Biao; Xu, Gaojie
2018-07-20
A facial method of fabricating methyl-modified silica nanobowl using a polystyrene template with tetraethoxysilane (TEOS) and methyltriethoxysilane (MTES) as co-precursors was reported. The morphology of the nanobowl was determined by the mole ratio of TEOS and MTES, and the size and shell thickness of the PS@SiO 2 . And the 2D ordered nanostructure has also been developed with a nanobowl opening perpendicular to the glass substrate surface by the Langmuir-Blodgett technique. These 2D ordered nanobowl structures present an adjustable antireflection property. The single-side nanobowl coating has a transmission improvement of 4.5% compared to the uncoated glass at a wavelength of 540 nm. Furthermore, the nanobowl structures have good hydrophobicity with a contact angle up to 130° without any additional treatment. The quantitative deformation behavior of the methyl-modified silica nanobowl was also discussed.
Rapid and Facile Microwave-Assisted Surface Chemistry for Functionalized Microarray Slides
Lee, Jeong Heon; Hyun, Hoon; Cross, Conor J.; Henary, Maged; Nasr, Khaled A.; Oketokoun, Rafiou; Choi, Hak Soo; Frangioni, John V.
2011-01-01
We describe a rapid and facile method for surface functionalization and ligand patterning of glass slides based on microwave-assisted synthesis and a microarraying robot. Our optimized reaction enables surface modification 42-times faster than conventional techniques and includes a carboxylated self-assembled monolayer, polyethylene glycol linkers of varying length, and stable amide bonds to small molecule, peptide, or protein ligands to be screened for binding to living cells. We also describe customized slide racks that permit functionalization of 100 slides at a time to produce a cost-efficient, highly reproducible batch process. Ligand spots can be positioned on the glass slides precisely using a microarraying robot, and spot size adjusted for any desired application. Using this system, we demonstrate live cell binding to a variety of ligands and optimize PEG linker length. Taken together, the technology we describe should enable high-throughput screening of disease-specific ligands that bind to living cells. PMID:23467787
Microfluidic Controlled Conformal Coating of Particles
NASA Astrophysics Data System (ADS)
Tsai, Scott; Wexler, Jason; Wan, Jiandi; Stone, Howard
2011-11-01
Coating flows are an important class of fluid mechanics problems. Typically a substrate is coated with a moving continuous film, but it is also possible to consider coating of discrete objects. In particular, in applications involving coating of particles that are useful in drug delivery, the coatings act as drug-carrying vehicles, while in cell therapy a thin polymeric coating is required to protect the cells from the host's immune system. Although many functional capabilities have been developed for lab-on-a-chip devices, a technique for coating has not been demonstrated. We present a microfluidic platform developed to coat micron-size spheres with a thin aqueous layer by magnetically pulling the particles from the aqueous phase to the non-aqueous phase in a co-flow. Coating thickness can be adjusted by the average fluid speed and the number of beads encapsulated inside a single coat is tuned by the ratio of magnetic to interfacial forces acting on the beads.
NASA Astrophysics Data System (ADS)
Geremariam Welearegay, Tesfalem; Cindemir, Umut; Österlund, Lars; Ionescu, Radu
2018-02-01
Here, we report for the first time the fabrication of ligand-functionalised ultrapure monodispersed metal nanoparticles (Au, Cu, and Pt) from their pure metal precursors using the advanced gas deposition technique. The experimental conditions during nanoparticle formation were adjusted in order to obtain ultrafine isolated nanoparticles on different substrates. The morphology and surface analysis of the as-deposited metal nanoparticles were investigated using scanning electron microscopy, x-ray diffraction and Fourier transform infra-red spectroscopy, which demonstrated the formation of highly ordered pure crystalline nanoparticles with a relatively uniform size distribution of ∼10 nm (Au), ∼4 nm (Cu) and ∼3 nm (Pt), respectively. A broad range of organic ligands containing thiol or amine functional groups were attached to the nanoparticles to form continuous networks of nanoparticle-ligand nanoassemblies, which were characterised by scanning electron microscopy and x-ray photoelectron spectroscopy. The electrical resistance of the functional nanoassemblies deposited in the gap spacing of two microfabricated parallel Au electrodes patterned on silicon substrates ranged between tens of kΩ and tens of MΩ, which is suitable for use in many applications including (bio)chemical sensors, surface-enhanced Raman spectroscopy and molecular electronic rectifiers.
Accelerated Training for Large Feedforward Neural Networks
NASA Technical Reports Server (NTRS)
Stepniewski, Slawomir W.; Jorgensen, Charles C.
1998-01-01
In this paper we introduce a new training algorithm, the scaled variable metric (SVM) method. Our approach attempts to increase the convergence rate of the modified variable metric method. It is also combined with the RBackprop algorithm, which computes the product of the matrix of second derivatives (Hessian) with an arbitrary vector. The RBackprop method allows us to avoid computationally expensive, direct line searches. In addition, it can be utilized in the new, 'predictive' updating technique of the inverse Hessian approximation. We have used directional slope testing to adjust the step size and found that this strategy works exceptionally well in conjunction with the Rbackprop algorithm. Some supplementary, but nevertheless important enhancements to the basic training scheme such as improved setting of a scaling factor for the variable metric update and computationally more efficient procedure for updating the inverse Hessian approximation are presented as well. We summarize by comparing the SVM method with four first- and second- order optimization algorithms including a very effective implementation of the Levenberg-Marquardt method. Our tests indicate promising computational speed gains of the new training technique, particularly for large feedforward networks, i.e., for problems where the training process may be the most laborious.
Wearable Electronics and Smart Textiles: A Critical Review
Stoppa, Matteo; Chiolerio, Alessandro
2014-01-01
Electronic Textiles (e-textiles) are fabrics that feature electronics and interconnections woven into them, presenting physical flexibility and typical size that cannot be achieved with other existing electronic manufacturing techniques. Components and interconnections are intrinsic to the fabric and thus are less visible and not susceptible of becoming tangled or snagged by surrounding objects. E-textiles can also more easily adapt to fast changes in the computational and sensing requirements of any specific application, this one representing a useful feature for power management and context awareness. The vision behind wearable computing foresees future electronic systems to be an integral part of our everyday outfits. Such electronic devices have to meet special requirements concerning wearability. Wearable systems will be characterized by their ability to automatically recognize the activity and the behavioral status of their own user as well as of the situation around her/him, and to use this information to adjust the systems' configuration and functionality. This review focuses on recent advances in the field of Smart Textiles and pays particular attention to the materials and their manufacturing process. Each technique shows advantages and disadvantages and our aim is to highlight a possible trade-off between flexibility, ergonomics, low power consumption, integration and eventually autonomy. PMID:25004153
Wearable electronics and smart textiles: a critical review.
Stoppa, Matteo; Chiolerio, Alessandro
2014-07-07
Electronic Textiles (e-textiles) are fabrics that feature electronics and interconnections woven into them, presenting physical flexibility and typical size that cannot be achieved with other existing electronic manufacturing techniques. Components and interconnections are intrinsic to the fabric and thus are less visible and not susceptible of becoming tangled or snagged by surrounding objects. E-textiles can also more easily adapt to fast changes in the computational and sensing requirements of any specific application, this one representing a useful feature for power management and context awareness. The vision behind wearable computing foresees future electronic systems to be an integral part of our everyday outfits. Such electronic devices have to meet special requirements concerning wearability. Wearable systems will be characterized by their ability to automatically recognize the activity and the behavioral status of their own user as well as of the situation around her/him, and to use this information to adjust the systems' configuration and functionality. This review focuses on recent advances in the field of Smart Textiles and pays particular attention to the materials and their manufacturing process. Each technique shows advantages and disadvantages and our aim is to highlight a possible trade-off between flexibility, ergonomics, low power consumption, integration and eventually autonomy.
Dahab, Gamal M; Kheriza, Mohamed M; El-Beltagi, Hussien M; Fouda, Abdel-Motaal M; El-Din, Osama A Sharaf
2004-01-01
The precise quantification of fibrous tissue in liver biopsy sections is extremely important in the classification, diagnosis and grading of chronic liver disease, as well as in evaluating the response to antifibrotic therapy. Because the recently described methods of digital image analysis of fibrosis in liver biopsy sections have major flaws, including the use of out-dated techniques in image processing, inadequate precision and inability to detect and quantify perisinusoidal fibrosis, we developed a new technique in computerized image analysis of liver biopsy sections based on Adobe Photoshop software. We prepared an experimental model of liver fibrosis involving treatment of rats with oral CCl4 for 6 weeks. After staining liver sections with Masson's trichrome, a series of computer operations were performed including (i) reconstitution of seamless widefield images from a number of acquired fields of liver sections; (ii) image size and solution adjustment; (iii) color correction; (iv) digital selection of a specified color range representing all fibrous tissue in the image and; (v) extraction and calculation. This technique is fully computerized with no manual interference at any step, and thus could be very reliable for objectively quantifying any pattern of fibrosis in liver biopsy sections and in assessing the response to antifibrotic therapy. It could also be a valuable tool in the precise assessment of antifibrotic therapy to other tissue regardless of the pattern of tissue or fibrosis.
Sim, Julius; Lewis, Martyn
2012-03-01
To investigate methods to determine the size of a pilot study to inform a power calculation for a randomized controlled trial (RCT) using an interval/ratio outcome measure. Calculations based on confidence intervals (CIs) for the sample standard deviation (SD). Based on CIs for the sample SD, methods are demonstrated whereby (1) the observed SD can be adjusted to secure the desired level of statistical power in the main study with a specified level of confidence; (2) the sample for the main study, if calculated using the observed SD, can be adjusted, again to obtain the desired level of statistical power in the main study; (3) the power of the main study can be calculated for the situation in which the SD in the pilot study proves to be an underestimate of the true SD; and (4) an "efficient" pilot size can be determined to minimize the combined size of the pilot and main RCT. Trialists should calculate the appropriate size of a pilot study, just as they should the size of the main RCT, taking into account the twin needs to demonstrate efficiency in terms of recruitment and to produce precise estimates of treatment effect. Copyright © 2012 Elsevier Inc. All rights reserved.
How best to assess suppression in patients with high anisometropia.
Li, Jinrong; Hess, Robert F; Chan, Lily Y L; Deng, Daming; Chen, Xiang; Yu, Minbin; Thompson, Benjamin S
2013-02-01
We have recently described a rapid technique for measuring suppression using a dichoptic signal/noise task. Here, we report a modification of this technique that allows for accurate measurements to be made in amblyopic patients with high levels of anisometropia. This was necessary because aniseikonic image size differences between the two eyes can provide a cue for signal/noise segregation and, therefore, influence suppression measurement in these patients. Suppression was measured using our original technique and with a modified technique whereby the size of the signal and noise elements was randomized across the stimulus to eliminate size differences as a cue for task performance. Eleven patients with anisometropic amblyopia, five with more than 5 diopters (D) spherical equivalent difference (SED), six with less than 5 D SED between the eyes, and 10 control observers completed suppression measurements using both techniques. Suppression measurements in controls and patients with less than 5 D SED were constant across the two techniques; however, patients with more than 5 D SED showed significantly stronger suppression on the modified technique with randomized element size. Measurements made with the modified technique correlated with the loss of visual acuity in the amblyopic eye and were in good agreement with previous reports using detailed psychophysical measurements. The signal/noise technique for measuring suppression can be applied to patients with high levels of anisometropia and aniseikonia if element size is randomized. In addition, deeper suppression is associated with a greater loss of visual acuity in patients with anisometropic amblyopia.
Data-driven inference for the spatial scan statistic.
Almeida, Alexandre C L; Duarte, Anderson R; Duczmal, Luiz H; Oliveira, Fernando L P; Takahashi, Ricardo H C
2011-08-02
Kulldorff's spatial scan statistic for aggregated area maps searches for clusters of cases without specifying their size (number of areas) or geographic location in advance. Their statistical significance is tested while adjusting for the multiple testing inherent in such a procedure. However, as is shown in this work, this adjustment is not done in an even manner for all possible cluster sizes. A modification is proposed to the usual inference test of the spatial scan statistic, incorporating additional information about the size of the most likely cluster found. A new interpretation of the results of the spatial scan statistic is done, posing a modified inference question: what is the probability that the null hypothesis is rejected for the original observed cases map with a most likely cluster of size k, taking into account only those most likely clusters of size k found under null hypothesis for comparison? This question is especially important when the p-value computed by the usual inference process is near the alpha significance level, regarding the correctness of the decision based in this inference. A practical procedure is provided to make more accurate inferences about the most likely cluster found by the spatial scan statistic.
Negative Thermal Expansion and Ferroelectric Oxides in Electronic Device Composites
NASA Astrophysics Data System (ADS)
Trujillo, Joy Elizabeth
Electronic devices increasingly pervade our daily lives, driving the need to develop components which have material properties that can be designed to target a specific need. The principle motive of this thesis is to investigate the effects of particle size and composition on three oxides which possess electronic and thermal properties essential to designing improved ceramic composites for more efficient, high energy storage devices. A metal matrix composite project used the negative thermal expansion oxide, ZrW2O 8, to offset the high thermal expansion of the metal matrix without sacrificing high thermal conductivity. Composite preparation employed a powder mixing technique to achieve easy composition control and homogenous phase distribution in order to build composites which target a specific coefficient of thermal expansion (CTE). A tailorable CTE material is desirable for overcoming thermomechanical failure in heat sinks or device casings. This thesis also considers the particle size effect on dielectric properties in a common ferroelectric perovskite, Ba1-xSrxTiO 3. By varying the Ba:Sr ratio, the Curie temperature can be adjusted and by reducing the particle size, the dielectric constant can be increased and hysteresis decreased. These conditions could yield anonymously large dielectric constants near room temperature. However, the ferroelectric behavior has been observed to cease below a minimum size of a few tens of nanometers in bulk or thin film materials. Using a new particle slurry approach, electrochemical impedance spectroscopy allows dielectric properties to be determined for nanoparticles, as opposed to conventional methods which measure only bulk or thin film dielectric properties. In this manner, Ba1-xSrxTiO3 was investigated in a new size regime, extending the theory on the ferroelectric behavior to < 10 nm diameter. This knowledge will improve the potential to incorporate high dielectric constant, low loss ferroelectric nanoparticles in many complex composites. Finally, powder composite processing and impedance spectroscopy techniques were combined to investigate the SrTiO3/(Y2O3) x(ZrO2)1-x (STO/YSZ) oxide system. Thin film heterostructures of STO/YSZ are used in electrochemical energy devices due to their enhanced interfacial ionic conductivity. This work investigated whether this ionic conductivity enhancement could be observed in bulk sintered architectures, which may lead to new device designs for energy storage needs.
Accounting for body size deviations when reporting bone mineral density variables in children.
Webber, C E; Sala, A; Barr, R D
2009-01-01
In a child, bone mineral density (BMD) may differ from an age-expected normal value, not only because of the presence of disease, but also because of deviations of height or weight from population averages. Appropriate adjustment for body size deviations simplifies interpretation of BMD measurements. For children, a bone mineral density (BMD) measurement is normally expressed as a Z score. Interpretation is complicated when weight or height distinctly differ from age-matched children. We develop a procedure to allow for the influence of body size deviations upon measured BMD. We examined the relation between body size deviation and spine, hip and whole body BMD deviation in 179 normal children (91 girls). Expressions were developed that allowed derivation of an expected BMD based on age, gender and body size deviation. The difference between measured and expected BMD was expressed as a HAW score (Height-, Age-, Weight-adjusted score). In a second independent sample of 26 normal children (14 girls), measured spine, total femur and whole body BMD all fell within the same single normal range after accounting for age, gender and body size deviations. When traditional Z scores and HAW scores were compared in 154 children, 17.5% showed differences of more than 1 unit and such differences were associated with height and weight deviations. For almost 1 in 5 children, body size deviations influence BMD to an extent that could alter clinical management.
Locomotor performance in highly-trained young soccer players: does body size always matter?
Buchheit, M; Mendez-Villanueva, A; Mayer, N; Jullien, H; Marles, A; Bosquet, L; Maille, P; Morin, J-B; Cazorla, G; Lambert, P
2014-06-01
To examine the effects of body size on locomotor performance, 807 15-year-old French and 64 Qatari soccer players participated in the present study. They performed a 40-m sprint and an incremental running test to assess maximal sprinting (MSS) and aerobic speeds, respectively. French players were advanced in maturity, taller, heavier, faster and fitter than their Qatari counterparts (e.g., Cohen's d=+1.3 and + 0.5 for body mass and MSS). However, when adjusted for body mass (BM), Qatari players had possibly greater MSS than French players (d=+0.2). A relative age effect was observed within both countries, with the players born in the first quarter of the year being taller, heavier and faster that those born during the fourth quarter (e.g., d=+0.2 for MSS in French players). When directly adjusted for BM, these MSS differences remained (d=+0.2). Finally, in both countries, players selected in National teams were taller, heavier, faster and fitter than their non-selected counterparts (e.g., d=+0.6 for MSS in French players), even after adjustments for body size (d=+0.5). Differences in locomotor performances between players with different phenotypes are likely mediated by differences in body size. However, when considering more homogeneous player groups, body dimensions are unlikely to substantially explain the superior locomotor performances of older and/or international players. © Georg Thieme Verlag KG Stuttgart · New York.
Effective fiber for lactating dairy cows: a physically adjusted NDF (paNDF) system
USDA-ARS?s Scientific Manuscript database
Multiplying dietary NDF by particle size (PS) has been used as an estimate of physically effective fiber (peNDF). Our objectives were to: 1) compare the use of peNDF as dietary NDF × PS vs. use of individual NDF and PS descriptors in a physically adjusted NDF (paNDF) system when used with other fact...
Remote control for anode-cathode adjustment
Roose, Lars D.
1991-01-01
An apparatus for remotely adjusting the anode-cathode gap in a pulse power machine has an electric motor located within a hollow cathode inside the vacuum chamber of the pulse power machine. Input information for controlling the motor for adjusting the anode-cathode gap is fed into the apparatus using optical waveguides. The motor, controlled by the input information, drives a worm gear that moves a cathode tip. When the motor drives in one rotational direction, the cathode is moved toward the anode and the size of the anode-cathode gap is diminished. When the motor drives in the other direction, the cathode is moved away from the anode and the size of the anode-cathode gap is increased. The motor is powered by batteries housed in the hollow cathode. The batteries may be rechargeable, and they may be recharged by a photovoltaic cell in combination with an optical waveguide that receives recharging energy from outside the hollow cathode. Alternatively, the anode-cathode gap can be remotely adjusted by a manually-turned handle connected to mechanical linkage which is connected to a jack assembly. The jack assembly converts rotational motion of the handle and mechanical linkage to linear motion of the cathode moving toward or away from the anode.
Surgical treatment of pectoralis major muscle rupture with adjustable cortical button.
Pochini, Alberto de Castro; Rodrigues, Marcus de Souza Barbosa; Yamashita, Larissa; Belangero, Paulo Santoro; Andreoli, Carlos Vicente; Ejnisman, Benno
2018-01-01
To assess the tendon reconstruction technique for total rupture of the pectoralis major muscle using an adjustable cortical button. Prospective study of 27 male patients with a mean age of 29.9 (SD = 5.3 years) and follow-up of 2.3 years. The procedure consisted of autologous grafts taken from the semitendinosus and gracilis tendons and an adjustable cortical button. Patients were evaluated functionally by the Bak criteria. The surgical treatment of pectoralis major muscle tendon reconstruction was performed in the early stages (three weeks) in six patients (22.2%) and in 21 patients (77.8%), in the late stages. Patients operated with the adjustable cortical button technique obtained 96.3% excellent or good results, with only 3.7% having poor results (Bak criteria). Of the total, 85.2% were injured while performing bench press exercises and 14.8%, during the practice of Brazilian jiu-jitsu or wrestling. All weight-lifting athletes had history of anabolic steroid use. The early or delayed reconstruction of ruptured pectoralis major muscle tendons with considerable muscle retraction, using an adjustable cortical button and autologous knee flexor grafts, showed a high rate of good results.
Worksheets for computing recommended notebook computer and workstation adjustments.
Nanthavanij, Suebsak; Udomratana, Chatkate; Hansawad, Saowalak; Thepkanjana, Jayaporn; Tantasuwan, Wanchalerm
2013-01-01
This paper discusses the design and development of worksheets for helping notebook computer (NBC) users to compute NBC and workstation adjustments so as to assume an appropriate seated posture. The worksheets (one for male users, the other for female ones) require the following information: body height, NBC screen size, work surface height, and seat height. The worksheets contain tables for estimating recommended NBC base angle, NBC screen angle, body-NBC distance, work surface height, and seat height. Additionally, they include flow charts to help NBC users to determine necessary adjustment accessories and their settings.
Reproductive success of Horned Lark and McCown's Longspur in relation to wind energy infrastructure
Mahoney, Anika; Chalfoun, Anna D.
2016-01-01
Wind energy is a rapidly expanding industry with potential indirect effects to wildlife populations that are largely unexplored. In 2011 and 2012, we monitored 211 nests of 2 grassland songbirds, Horned Lark (Eremophila alpestris) and McCown's Longspur (Rhynchophanes mccownii), at 3 wind farms and 2 undeveloped reference sites in Wyoming, USA. We evaluated several indices of reproductive investment and success: clutch size, size-adjusted nestling mass, daily nest survival rate, and number of fledglings. We compared reproductive success between wind farms and undeveloped sites and modeled reproductive success within wind farms as a function of wind energy infrastructure and habitat. Size-adjusted nestling mass of Horned Lark was weakly negatively related to turbine density. In 2011, nest survival of Horned Lark decreased 55% as turbine density increased from 10 to 39 within 2 km of the nest. In 2012, however, nest survival of Horned Lark was best predicted by the combination of vegetation height, distance to shrub edge, and turbine density, with survival increasing weakly with increasing vegetation height. McCown's Longspur nest survival was weakly positively related to vegetation density at the nest site when considered with the amount of grassland habitat in the neighborhood and turbine density within 1 km of the nest. Habitat and distance to infrastructure did not explain clutch size or number of fledglings for either species, or size-adjusted nestling mass for McCown's Longspur. Our results suggest that the influence of wind energy infrastructure varies temporally and by species, even among species using similar habitats. Turbine density was repeatedly the most informative measure of wind energy development. Turbine density could influence wildlife responses to wind energy production and may become increasingly important to consider as development continues in areas with high-quality wind resources.
Chen, Yen-Po; Prashar, Ankush; Hocking, Paul M; Erichsen, Jonathan T; To, Chi Ho; Schaeffel, Frank; Guggenheim, Jeremy A
2010-02-01
There is considerable variation in the degree of form-deprivation myopia (FDM) induced in chickens by a uniform treatment regimen. Sex and pretreatment eye size have been found to be predictive of the rate of FD-induced eye growth. Therefore, this study was undertaken to test whether the greater rate of myopic eye growth in males is a consequence of their larger eyes or of some other aspect of their sex. Monocular FDM was induced in 4-day-old White Leghorn chicks for 4 days. Changes in ocular component dimensions and refractive error were assessed by A-scan ultrasonography and retinoscopy, respectively. Sex identification of chicks was performed by DNA test. Relationships between traits were assessed by multiple regression. FD produced (mean +/- SD) 13.47 +/- 3.12 D of myopia and 0.47 +/- 0.14 mm of vitreous chamber elongation. The level of induced myopia was not significantly different between the sexes, but the males had larger eyes initially and showed greater myopic eye growth than did the females. In multiple linear regression analysis, the partial correlation between sex and the degree of induced eye growth remained significant (P = 0.008) after adjustment for eye size, whereas the partial correlation between initial eye size and the degree of induced eye growth was no longer significant after adjustment for sex (P = 0.11). After adjustment for other factors, the chicks' sex accounted for 6.4% of the variation in FD-induced vitreous chamber elongation. The sex of the chick influences the rate of experimentally induced myopic eye growth, independent of its effects on eye size.
Yan, Ning; Yang, Anli; Liu, Xiaodong; Cai, Feng; Liu, Liang; Chang, Shimin
2014-03-01
Although the cannulated screw and cable (CSC) tension band technique is an effective method for fixation of transverse patellar fractures, it has shortcomings, such as extensive soft tissue damage, osseous substance damage, and complex manipulation. We conducted a retrospective comparison of the adjustable patella grapple (APG) technique and the CSC tension band technique. We retrospectively reviewed 78 patients with transverse patellar fractures (45 in the APG group and 33 in the CSC group). Follow-up was 18 months. Comparison criteria were operation time, fracture reduction, fracture healing time, the knee injury and osteoarthritis outcome score for knee function, and complications. The APG group showed shorter operation time and equal fracture reduction, fracture healing time, and knee function compared with the CSC group. Eleven patients in the APG group experienced skin irritation generated by implants. There was no complication in the CSC group. The APG technique should be considered as an alternative method for treatment of transverse patellar fractures.
MO-E-18A-01: Imaging: Best Practices In Pediatric Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Willis, C; Strauss, K; MacDougall, R
This imaging educational program will focus on solutions to common pediatric imaging challenges. The speakers will present collective knowledge on best practices in pediatric imaging from their experience at dedicated children's hospitals. Areas of focus will include general radiography, the use of manual and automatic dose management in computed tomography, and enterprise-wide radiation dose management in the pediatric practice. The educational program will begin with a discussion of the complexities of exposure factor control in pediatric projection radiography. Following this introduction will be two lectures addressing the challenges of computed tomography (CT) protocol optimization in the pediatric population. The firstmore » will address manual CT protocol design in order to establish a managed radiation dose for any pediatric exam on any CT scanner. The second CT lecture will focus on the intricacies of automatic dose modulation in pediatric imaging with an emphasis on getting reliable results in algorithmbased technique selection. The fourth and final lecture will address the key elements needed to developing a comprehensive radiation dose management program for the pediatric environment with particular attention paid to new regulations and obligations of practicing medical physicists. Learning Objectives: To understand how general radiographic techniques can be optimized using exposure indices in order to improve pediatric radiography. To learn how to establish diagnostic dose reference levels for pediatric patients as a function of the type of examination, patient size, and individual design characteristics of the CT scanner. To learn how to predict the patient's radiation dose prior to the exam and manually adjust technique factors if necessary to match the patient's dose to the department's established dose reference levels. To learn how to utilize manufacturer-provided automatic dose modulation technology to consistently achieve patient doses within the department's established size-based diagnostic reference range. To understand the key components of an enterprise-wide pediatric dose management program that integrates the expanding responsibilities of medial physicists in the new era of dose monitoring.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parsons, David, E-mail: david.parsons@dal.ca, E-mail: james.robar@cdha.nshealth.ca; Robar, James L., E-mail: david.parsons@dal.ca, E-mail: james.robar@cdha.nshealth.ca
2015-09-15
Purpose: The focus of this work was to investigate the improvements in image quality and dose reduction for volume-of-interest (VOI) kilovoltage-cone beam CT (CBCT) using dynamic collimation. Methods: A prototype iris aperture was used to track a VOI during a CBCT acquisition. The current aperture design is capable of 1D translation as a function of gantry angle and dynamic adjustment of the iris radius. The aperture occupies the location of the bow-tie filter on a Varian On-Board Imager system. CBCT and planar image quality were investigated as a function of aperture radius, while maintaining the same dose to the VOI,more » for a 20 cm diameter cylindrical water phantom with a 9 mm diameter bone insert centered on isocenter. Corresponding scatter-to-primary ratios (SPR) were determined at the detector plane with Monte Carlo simulation using EGSnrc. Dose distributions for various sizes VOI were modeled using a dynamic BEAMnrc library and DOSXYZnrc. The resulting VOI dose distributions were compared to full-field distributions. Results: SPR was reduced by a factor of 8.4 when decreasing iris diameter from 21.2 to 2.4 cm (at isocenter). Depending upon VOI location and size, dose was reduced to 16%–90% of the full-field value along the central axis plane and down to 4% along the axis of rotation, while maintaining the same dose to the VOI compared to full-field techniques. When maintaining constant dose to the VOI, this change in iris diameter corresponds to a factor increase of approximately 1.6 in image contrast and a factor decrease in image noise of approximately 1.2. This results in a measured gain in contrast-to-noise ratio by a factor of approximately 2.0. Conclusions: The presented VOI technique offers improved image quality for image-guided radiotherapy while sparing the surrounding volume of unnecessary dose compared to full-field techniques.« less
Hood, Glen R; Ott, James R
2017-04-01
Successive generations of bi- and multivoltine species encounter differing biotic and abiotic environments intra-annually. The question of whether selection can independently adjust the relationship between body size and components of reproductive effort within successive generations in response to generation-specific environmental variation is applicable to a diversity of taxa. Herein, we develop a conceptual framework that illustrates increasingly independent life history adjustments between successive generations of taxa exhibiting complex life cycles. We apply this framework to the reproductive biology of the gall-forming insect, Belonocnema treatae (Hymenoptera: Cynipidae). This bivoltine species expresses cyclical parthenogenesis in which alternating sexual and asexual generations develop in different seasons and different environments. We tested the hypotheses that ecological divergence between the alternate generations is accompanied by generational differences in body size, egg size, and egg number and by changes in the relationships between body size and these components of reproductive effort. Increased potential reproductive effort of sexual generation B. treatae is attained by increased body size and egg number (with no trade-off between egg number and egg size) and by a significant increase in the slope of the relationship between body size and potential fecundity. These generation-specific relationships, interpreted in the context of the model framework, suggest that within each generation selection has independently molded the relationships relating body size to potential fecundity and potential reproductive effort in B. treatae. The conceptual framework is broadly applicable to comparisons involving the alternating generations of bi- and multivoltine species.
Two-window heterodyne methods to characterize light fields
NASA Astrophysics Data System (ADS)
Reil, Frank
In this dissertation, I develop a novel Two-Window heterodyne technique for measuring the time-resolved Wigner function of light fields, which allows their complete characterization. A Wigner function is a quasi-probability density that describes the transverse position and transverse momentum of a light field and is Fourier-transform related to its mutual coherence function. It obeys rigorous transport equations and therefore provides an ideal way to characterize a light field and its propagation through various media. I first present the experimental setup of our Two-Window technique, which is based on a heterodyne scheme involving two phase-coupled Local Oscillator beams we call the Dual-LO. The Dual-LO consists of a focused beam ('SLO') which sets the spatial resolution, and a collimated beam ('BLO') which sets the momental resolution. The resolution in transverse position and transverse momentum can be adjusted individually by the size of the SLO and BLO, which enables a measurement resolution surpassing the uncertainty principle associated with Fourier-transform pairs which limits the resolution when just a single LO is used. We first use our technique to determine the beam size, transverse coherence length and radius of curvature of a Gaussian-Schell beam, as well as its longitudinal characteristics, which are related to its optical spectrum. We then examine Enhanced Backscattering at various path-lengths in the turbid medium. For the first time ever, we demonstrate the phase-conjugating properties of a turbid medium by observing the change in sign of the radius of curvature for a non-collimated field incident on the medium. We also perform time-resolved measurements in the transmission regime. In tenuous media we observe two peaks in phase-space confined by a hyperbola which are due to low-order scattering. Their distance depends on the chosen path-delay. Some coherence and even spatial properties of the incident field are preserved in those peaks as measurements with our Two-Window technique show. Various other applications are presented in less detail, such as the Wigner function of the field inside a speckle produced by a piece of glass containing air bubbles.
Wohl, P; Krusinová, E; Klementová, M; Wohl, P; Kratochvílová, S; Pelikánová, T
2008-01-01
The hyperinsulinemic euglycemic clamp (HEC) combined with indirect calorimetry (IC) is used for estimation of insulin-stimulated substrate utilization. Calculations are based on urinary urea nitrogen excretion (UE), which is influenced by correct urine collection. The aims of our study were to improve the timing of urine collection during the clamp and to test the effect of insulin on UE in patients with type 1 diabetes (DM1; n=11) and healthy subjects (C; n=11). Urine samples were collected (a) over 24 h divided into 3-h periods and (b) before and during two-step clamp (1 and 10 mIU.kg(-1).min(-1); period 1 and period 2) combined with IC. The UE during the clamp was corrected for changes in urea pool size (UEc). There were no significant differences in 24-h UE between C and DM1 and no circadian variation in UE in either group. During the clamp, serum urea decreased significantly in both groups (p<0.01). Therefore, UEc was significantly lower as compared to UE not adjusted for changes in urea pool size both in C (p<0.001) and DM1 (p<0.001). While UE did not change during the clamp, UEc decreased significantly in both groups (p<0.01). UEc during the clamp was significantly higher in DM1 compared to C both in period 1 (p<0.05) and period 2 (p<0.01). The UE over 24 h and UEc during the clamp were statistically different in both C and DM1. We conclude that urine collection performed during the clamp with UE adjusted for changes in urea pool size is the most suitable technique for measuring substrate utilization during the clamp both in DM1 and C. Urine collections during the clamp cannot be replaced either by 24-h sampling (periods I-VII) or by a single 24-h urine collection. Attenuated insulin-induced decrease in UEc in DM1 implicates the impaired insulin effect on proteolysis.
Simulation of two-dimensional adjustable liquid gradient refractive index (L-GRIN) microlens
NASA Astrophysics Data System (ADS)
Le, Zichun; Wu, Xiang; Sun, Yunli; Du, Ying
2017-07-01
In this paper, a two-dimensional liquid gradient refractive index (L-GRIN) microlens is designed which can be used in adjusting focusing direction and focal spot of light beam. Finite element method (FEM) is used to simulate the convection diffusion process happening in core inlet flow and cladding inlet flow. And the ray tracing method shows us the light beam focusing effect including the extrapolation of focal length and output beam spot size. When the flow rates of the core and cladding fluids are held the same between the internal and external, left and right, and upper and lower inlets, the focal length varied from 313 μm to 53.3 μm while the flow rate of liquids ranges from 500 pL/s to 10,000 pL/s. While the core flow rate is bigger than the cladding inlet flow rate, the light beam will focus on a light spot with a tunable size. By adjusting the ratio of cladding inlet flow rate including Qright/Qleft and Qup/Qdown, we get the adjustable two-dimensional focus direction rather than the one-dimensional focusing. In summary, by adjusting the flow rate of core inlet and cladding inlet, the focal length, output beam spot and focusing direction of the input light beam can be manipulated. We suppose this kind of flexible microlens can be used in integrated optics and lab-on-a-chip system.
Information-Adaptive Image Encoding and Restoration
NASA Technical Reports Server (NTRS)
Park, Stephen K.; Rahman, Zia-ur
1998-01-01
The multiscale retinex with color restoration (MSRCR) has shown itself to be a very versatile automatic image enhancement algorithm that simultaneously provides dynamic range compression, color constancy, and color rendition. A number of algorithms exist that provide one or more of these features, but not all. In this paper we compare the performance of the MSRCR with techniques that are widely used for image enhancement. Specifically, we compare the MSRCR with color adjustment methods such as gamma correction and gain/offset application, histogram modification techniques such as histogram equalization and manual histogram adjustment, and other more powerful techniques such as homomorphic filtering and 'burning and dodging'. The comparison is carried out by testing the suite of image enhancement methods on a set of diverse images. We find that though some of these techniques work well for some of these images, only the MSRCR performs universally well oil the test set.
An automatic step adjustment method for average power analysis technique used in fiber amplifiers
NASA Astrophysics Data System (ADS)
Liu, Xue-Ming
2006-04-01
An automatic step adjustment (ASA) method for average power analysis (APA) technique used in fiber amplifiers is proposed in this paper for the first time. In comparison with the traditional APA technique, the proposed method has suggested two unique merits such as a higher order accuracy and an ASA mechanism, so that it can significantly shorten the computing time and improve the solution accuracy. A test example demonstrates that, by comparing to the APA technique, the proposed method increases the computing speed by more than a hundredfold under the same errors. By computing the model equations of erbium-doped fiber amplifiers, the numerical results show that our method can improve the solution accuracy by over two orders of magnitude at the same amplifying section number. The proposed method has the capacity to rapidly and effectively compute the model equations of fiber Raman amplifiers and semiconductor lasers.
Wang, Rong; Xu, Xin
2015-12-01
To compare the effect of 2 methods of occlusion adjustment on occlusal balance and muscles of mastication in patients with dental implant restoration. Twenty patients, each with a single edentulous posterior dentition with no distal dentition were selected, and divided into 2 groups. Patients in group A underwent original occlusion adjustment method and patients in group B underwent occlusal plane reduction technique. Ankylos implants were implanted in the edentulous space in each patient and restored with fixed prosthodontics single unit crown. Occlusion was adjusted in each restoration accordingly. Electromyograms were conducted to determine the effect of adjustment methods on occlusion and muscles of mastication 3 months and 6 months after initial restoration and adjustment. Data was collected and measurements for balanced occlusal measuring standards were obtained, including central occlusion force (COF), asymmetry index of molar occlusal force(AMOF). Balanced muscles of mastication measuring standards were also obtained including measurements from electromyogram for the muscles of mastication and the anterior bundle of the temporalis muscle at the mandibular rest position, average electromyogram measurements of the anterior bundle of the temporalis muscle at the intercuspal position(ICP), Astot, masseter muscle asymmetry index, and anterior temporalis asymmetry index (ASTA). Statistical analysis was performed using Student 's t test with SPSS 18.0 software package. Three months after occlusion adjustment, parameters of the original occlusion adjustment method were significantly different between group A and group B in balanced occlusal measuring standards and balanced muscles of mastication measuring standards. Six months after occlusion adjustment, parameters of the original occlusion adjustment methods were significantly different between group A and group B in balanced muscles of mastication measuring standards, but was no significant difference in balanced occlusal measuring standards. Using occlusion plane reduction adjustment technique, it is possible to obtain occlusion index and muscles of mastication's electromyogram index similar to the opposite side's natural dentition in patients with single unit fix prosthodontics crown and single posterior edentulous dentition without distal dentitions.
Heimann, David C.
2017-10-24
The U.S. Geological Survey, in cooperation with the Missouri Department of Conservation and Missouri Department of Natural Resources, completed a study to assess a mechanical redistribution technique used for the management of large woody debris (LWD) jams in Locust Creek within Pershing State Park and Fountain Grove Conservation Area, Linn County, Missouri. Extensive LWD jams were treated from 1996 to 2009 using a low-impact technique in which LWD from the jams was redistributed to reopen the channel and to mimic the natural geomorphic process of channel migration and adjustment to an obstruction. The scope of the study included the comparison of selected channel geometry characteristics and bed material particle-size distribution in seven LWD treatment reaches with that of adjacent untreated reaches (unaffected by LWD accumulations) of Locust Creek. A comparison of 1996 and 2015 survey cross sections in treated and untreated reaches and photograph documentation were used to assess channel geomorphic change and the stability of redistributed LWD. The physical characteristics of LWD within jams present in the study reach during 2015–16 also were documented.Based on the general lack of differences in channel metrics between treated and untreated reaches, it can be concluded that the mechanical redistribution technique has been an effective treatment of extensive LWD jams in Locust Creek. Channel alterations, including aggradation, streamflow piracy, and diversions, have resulted in temporal and spatial changes in the Locust Creek channel that may affect future applications of the redistribution technique in Pershing State Park. The redistribution technique was used to effectively manage LWD in Locust Creek at a potentially lower financial cost and reduced environmental disturbance than the complete removal of LWD.A comparison of four channel metrics (bankfull cross-sectional area, channel width, streamflow capacity, and width-depth ratio) for individual treatment reaches with adjacent untreated reaches indicated no statistically significant difference in most comparisons. Where statistically significant differences in channel metrics were determined between individual reaches, the channel metrics in treatment reaches were significantly less than adjacent untreated reaches in some comparisons, and significantly greater than adjacent untreated reaches in others. Without immediate posttreatment cross sections in treated and untreated reaches for comparison, it is impossible to say with certainty that a lack of significant differences in channel metrics is a result of posttreatment channel adjustment or, conversely, that any significant differences that remain are a result of the treatment of LWD.Characteristics of LWD in accumulations sampled within the study area in 2015 indicate that most sampled pieces were in the 1–2 foot diameter size class, the 5–16 foot length class, and the advanced decay class. Most of documented LWD pieces were loose and not buried, about 20 percent on average had a root wad attached, and about 6.5 percent on average were sawn logs. Most of sampled material was less than one-half of the bankfull channel width, indicating it was easily transportable, and the advanced decay class of material entering the study area indicated that it was likely sourced from outside of Pershing State Park.Redistributed LWD associated with treatment seems to be intact in the 1996 treated reaches from direct observation and from inference because there was net channel aggradation between 1996 and 2015 in comparison surveys. The change in channel area resulting from aggradation in time (1996 to 2015) in treated and untreated reaches exceeded the differences in channel characteristics between the treated and untreated channels in 2015 surveys.
Navy bean flour particle size and protein content affect cake baking and batter quality
USDA-ARS?s Scientific Manuscript database
Whole navy bean flour and its fine and coarse particle size fractions were used to completely replace wheat flour in cakes. Replacement of wheat flour with whole bean flour significantly increased the protein content. The protein content was adjusted to three levels with navy bean starch. The effect...
A survey of outcome of adjustable suture as first operation in patients with strabismus
Razmjoo, Hasan; Attarzadeh, Hosein; Karbasi, Najmeh; Najarzadegan, Mohammad Reza; Salam, Hasan; Jamshidi, Aliraza
2014-01-01
Background: Adjustable suture used for years to improve the outcome of strabismus surgery. We surveyed outcome of our patients with strabismus who underwent adjustable suture. Materials and Methods: This retrospective study was performed at Ophthalmology Centre of Feiz Hospital in Isfahan on 95 participants that candidate for adjustable suture strabismus surgery. Patients were divided into three age groups: Under 10 years, 10-19 years, and 20 years and over. Outcome of adjustable suture surgery consequence of residual postoperative deviation was divided into four groups: Excellent, good, acceptable, and unacceptable. Results: Out of 95 patients studied, 51 (53.7%) were males and 44 (46.3%) were females. The mean of deviation angles were 53.8 ± 17.9 PD (Prism dioptres) in alt XT, 44.5 ± 12 PD in alt ET and 52 ± 13.5 PD in const ET, 47.1 ± 13.1PD in cons XT, respectively. There was no significant difference between the groups (P = 0.051). Results of surgery were in 38 patients (40%) excellent, in 31 patients (32.6%) good, in 19 patients (20%) acceptable, and in 7 patients (7.4%) unacceptable. Seven (7.4%) patients required reoperation. Conclusions: In the present study, the frequency of re-operation was much lower than other similar studies (7.4% vs. 30-50%). This suggests that the adjustable technique that used in our study can be associated with lower reoperation than other adjustable techniques used in the other similar studies. PMID:25250293
A survey of outcome of adjustable suture as first operation in patients with strabismus.
Razmjoo, Hasan; Attarzadeh, Hosein; Karbasi, Najmeh; Najarzadegan, Mohammad Reza; Salam, Hasan; Jamshidi, Aliraza
2014-01-01
Adjustable suture used for years to improve the outcome of strabismus surgery. We surveyed outcome of our patients with strabismus who underwent adjustable suture. This retrospective study was performed at Ophthalmology Centre of Feiz Hospital in Isfahan on 95 participants that candidate for adjustable suture strabismus surgery. Patients were divided into three age groups: Under 10 years, 10-19 years, and 20 years and over. Outcome of adjustable suture surgery consequence of residual postoperative deviation was divided into four groups: Excellent, good, acceptable, and unacceptable. Out of 95 patients studied, 51 (53.7%) were males and 44 (46.3%) were females. The mean of deviation angles were 53.8 ± 17.9 PD (Prism dioptres) in alt XT, 44.5 ± 12 PD in alt ET and 52 ± 13.5 PD in const ET, 47.1 ± 13.1PD in cons XT, respectively. There was no significant difference between the groups (P = 0.051). Results of surgery were in 38 patients (40%) excellent, in 31 patients (32.6%) good, in 19 patients (20%) acceptable, and in 7 patients (7.4%) unacceptable. Seven (7.4%) patients required reoperation. In the present study, the frequency of re-operation was much lower than other similar studies (7.4% vs. 30-50%). This suggests that the adjustable technique that used in our study can be associated with lower reoperation than other adjustable techniques used in the other similar studies.
Language Assessment Course: Structure, Delivery and Learning Outcomes
ERIC Educational Resources Information Center
Solnyshkina, Marina I.; Solovova, Elena N.; Harkova, Elena V.; Kiselnikov, Aleksander S.
2016-01-01
Aimed at developing methods, tools and techniques for delivery and evaluation of an educational module, this article addresses the needs of academicians restructuring, adjusting and altering their curricula to meet European Higher Education Area standards. The paper focuses on two pressing issues -- the applicability of and adjustment to European…
The Concept of Adjustment: A Structural Model.
ERIC Educational Resources Information Center
Dodds, A.; And Others
1994-01-01
This study analyzed scores of 469 British adult clients with recent loss of sight on the Nottingham Adjustment Scale using LISREL structural modeling techniques. Results supported a theoretical model of the self in terms of two latent factors--internal self-worth and self as agent. Implications for rehabilitation and intervention with cognitive…
NASA Astrophysics Data System (ADS)
Martín Furones, Angel; Anquela Julián, Ana Belén; Dimas-Pages, Alejandro; Cos-Gayón, Fernando
2017-08-01
Precise point positioning (PPP) is a well established Global Navigation Satellite System (GNSS) technique that only requires information from the receiver (or rover) to obtain high-precision position coordinates. This is a very interesting and promising technique because eliminates the need for a reference station near the rover receiver or a network of reference stations, thus reducing the cost of a GNSS survey. From a computational perspective, there are two ways to solve the system of observation equations produced by static PPP either in a single step (so-called batch adjustment) or with a sequential adjustment/filter. The results of each should be the same if they are both well implemented. However, if a sequential solution (that is, not only the final coordinates, but also those observed in previous GNSS epochs), is needed, as for convergence studies, finding a batch solution becomes a very time consuming task owing to the need for matrix inversion that accumulates with each consecutive epoch. This is not a problem for the filter solution, which uses information computed in the previous epoch for the solution of the current epoch. Thus filter implementations need extra considerations of user dynamics and parameter state variations between observation epochs with appropriate stochastic update parameter variances from epoch to epoch. These filtering considerations are not needed in batch adjustment, which makes it attractive. The main objective of this research is to significantly reduce the computation time required to obtain sequential results using batch adjustment. The new method we implemented in the adjustment process led to a mean reduction in computational time by 45%.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hsu, Wei-Hsiang; Hsiang, Hsing-I, E-mail: hsingi@mail.ncku.edu.tw; Chia, Chih-Ta
2013-12-15
CuIn{sub 0.7}Ga{sub 0.3}Se{sub 2}(CIGS) nano-crystals were successfully synthesized via a heating-up process. The non-coordinating solvent (1-octadecene) and selenium/cations ratio effects on the crystalline phase and crystallite size of CIGS nano-crystallites were investigated. It was observed that the CIGS nano-crystallite morphology changed from sheet into spherical shape as the amount of 1-octadecene addition was increased. CIGS nano-crystals were obtained in 9–20 nm sizes as the selenium/cations ratio increased. These results suggest that the monomer reactivity in the solution can be adjusted by changing the solvent type and selenium/cations ratio, hence affecting the crystallite size and distribution. - Graphical abstract: CuIn{sub 0.7}Ga{submore » 0.3}Se{sub 2}(CIGS) nano-crystals were successfully synthesized via a heating-up process in this study. The super-saturation in the solution can be adjusted by changing the OLA/ODE ratio and selenium/cation ratio.« less
The Association between Penis Size and Sexual Health among Men Who Have Sex with Men
Grov, Christian; Parsons, Jeffrey T.; Bimbi, David S.
2010-01-01
Larger penis size has been equated with a symbol of power, stamina, masculinity, and social status. Yet, there has been little research among men who have sex with men assessing the association between penis size and social-sexual health. Survey data from a diverse sample of 1,065 men who have sex with men were used to explore the association between perceived penis size and a variety of psychosocial outcomes. Seven percent of men felt their penis was “below average,” 53.9% “average,” and 35.5% “above average.” Penis size was positively related to satisfaction with size and inversely related to lying about penis size (all p < .01). Size was unrelated to condom use, frequency of sex partners, HIV status, or recent diagnoses of HBV, HCV, gonorrhea/Chlamydia/urinary tract infections, and syphilis. Men with above average penises were more likely to report HPV and HSV-2 (Fisher’s exact p ≤ .05). Men with below average penises were significantly more likely to identify as “bottoms” (anal receptive) and men with above average penises were significantly more likely to identify as tops (anal insertive). Finally, men with below average penises fared significantly worse than other men on three measures of psychosocial adjustment. Though most men felt their penis size was average, many fell outside this “norm.” The disproportionate number of viral skin-to-skin STIs (HSV-2 and HPV) suggest size may play a role in condom slippage/breakage. Further, size played a significant role in sexual positioning and psychosocial adjustment. These data highlight the need to better understand the real individual-level consequences of living in a penis-centered society. PMID:19139986
Differences in hospital casemix, and the relationship between casemix and hospital costs.
Söderlund, N; Milne, R; Gray, A; Raftery, J
1995-03-01
The aim of the study was to examine the relationship between hospital costs and casemix, and after adjustment for casemix differences, between cost and institutional size, number of specialties, occupancy and teaching status. A retrospective analysis of all admissions to nine acute-care NHS hospitals in the Oxford region during the 1991-1992 financial year was undertaken. All episodes were assigned to a diagnosis-related group (DRG) and a cost weight assigned accordingly. Costs per finished consultant episode, before and after adjustment for casemix differences, were analysed at the hospital and specialty level. Casemix differences were significant, and accounted for approximately 77 per cent of the difference in costs between providers. Costs per casemix-adjusted episode were not significantly associated with differences in hospital size, scope, occupancy levels or teaching status, but sample size was insufficient to investigate these relationships adequately. Specialty costs were poorly correlated with specialty casemix. This was probably due to poor apportionment of specialty costs in hospital accounting returns. Casemix differences need to be taken into account when comparing providers for the purposes of contracting, as unadjusted unit costs may be misleading. Although the methods used may currently be applied to most NHS hospitals, widespread use would be greatly facilitated by the development of indigenous cost weights and better routine hospital data coding and collection.
Dalskov, S; Ritz, C; Larnkjær, A; Damsgaard, C T; Petersen, R A; Sørensen, L B; Ong, K K; Astrup, A; Michaelsen, K F; Mølgaard, C
2016-04-01
We examined fat-independent associations of hormones with height and whole-body bone size and mineral content in 633 school children. IGF-1 and osteocalcin predict growth in height, while fat, osteocalcin, and in girls also, IGF-1 predict growth in bone size. Leptin and ghrelin are inversely associated with bone size in girls. Obesity causes larger bone size and bone mass, but the role of hormones in this up-regulation of bone in obesity is not well elucidated. We examined longitudinal associations between baseline body fat mass (FM), and fat-independent fasting levels of ghrelin, adiponectin, leptin, insulin, insulin-like growth factor-I (IGF-1), osteocalcin, and intact parathyroid hormone, and subsequent changes in height and in whole-body height-adjusted bone area "BAheight" and size-adjusted bone mineral content "BMCsize" in 8- to 11-year-olds. Analyses were carried out separately for boys (n = 325) and girls (n = 308) including data from baseline, 3 and 6 months from OPUS School Meal Study. In both sexes: gain in BAheight was positively associated with baseline FM (≥2.05 cm(2)/kg, both p ≤ 0.003). Furthermore, gain in height was positively associated with baseline IGF-1 (≥0.02 cm/ng/ml, p = 0.001) and osteocalcin (≥0.13 cm/ng/ml, p ≤ 0.009); and gain in BAheight was positively associated with baseline osteocalcin (≥0.35 cm(2)/ng/ml, p ≤ 0.019). In girls only, gain in BAheight was also positively associated with baseline IGF-1 (0.06 cm(2)/ng/ml, p = 0.017) and inversely associated with both baseline ghrelin (-0.01 cm(2)/pg/ml, p = 0.001) and leptin (-1.21 cm(2)/μg/ml, p = 0.005). In boys, gain in BMCsize was positively associated with osteocalcin (0.18 g/ng/ml, p = 0.030). This large longitudinal study suggests that in 8- to 11-year-old children, IGF-1 and osteocalcin predict growth in height, while FM, osteocalcin, and in girls also, IGF-1 predict growth in BAheight. Fat-independent inverse associations of leptin and ghrelin with BAheight in girls' are contrary to proposed growth-stimulating effects of leptin. Osteocalcin in boys predicts gain in BMCsize.
Nitrogen removal from digested slurries using a simplified ammonia stripping technique.
Provolo, Giorgio; Perazzolo, Francesca; Mattachini, Gabriele; Finzi, Alberto; Naldi, Ezio; Riva, Elisabetta
2017-11-01
This study assessed a novel technique for removing nitrogen from digested organic waste based on a slow release of ammonia that was promoted by continuous mixing of the digestate and delivering a continuous air stream across the surface of the liquid. Three 10-day experiments were conducted using two 50-L reactors. In the first two, nitrogen removal efficiencies were evaluated from identical digestates maintained at different temperatures (30°C and 40°C). At the start of the first experiment, the digestates were adjusted to pH 9 using sodium hydroxide, while in the second experiment pH was not adjusted. The highest ammonia removal efficiency (87%) was obtained at 40°C with pH adjustment. However at 40°C without pH adjustment, removal efficiencies of 69% for ammonia and 47% for total nitrogen were obtained. In the third experiment two different digestates were tested at 50°C without pH adjustment. Although the initial chemical characteristics of the digestates were different in this experiment, the ammonia removal efficiencies were very similar (approximately 85%). Despite ammonia removal, the pH increased in all experiments, most likely due to carbon dioxide stripping that was promoted by temperature and mixing. The technique proved to be suitable for removing nitrogen following anaerobic digestion of livestock manure because effective removal was obtained at natural pH (≈8) and 40°C, common operating conditions at typical biogas plants that process manure. Furthermore, the electrical energy requirement to operate the process is limited (estimated to be 3.8kWhm -3 digestate). Further improvements may increase the efficiency and reduce the processing time of this treatment technique. Even without these advances slow-rate air stripping of ammonia is a viable option for reducing the environmental impact associated with animal manure management. Copyright © 2017 Elsevier Ltd. All rights reserved.
78 FR 79286 - Truth in Lending (Regulation Z): Adjustment to Asset-Size Exemption Threshold
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-30
...The Bureau is amending the official commentary that interprets the requirements of the Bureau's Regulation Z (Truth in Lending) to reflect a change in the asset size threshold for certain creditors to qualify for an exemption to the requirement to establish an escrow account for a higher-priced mortgage loan based on the annual percentage change in the average of the Consumer Price Index for Urban Wage Earners and Clerical Workers (CPI-W) for the 12-month period ending in November. The exemption threshold is adjusted to increase to $2.028 billion from $2 billion. The adjustment is based on the 1.4 percent increase in the average of the CPI-W for the 12-month period ending in November 2013. Therefore, creditors with assets of $2.028 billion or less as of December 31, 2013, are exempt, if other requirements of Regulation Z also are met, from establishing escrow accounts for higher-priced mortgage loans in 2014.
Sawicki, Richard H.; Sweatt, William
1987-01-01
A technique for adjustably correcting for astigmatism in a light beam is disclosed herein. This technique utilizes first means which defines a flat, rectangular light reflecting surface having opposite reinforced side edges and which is resiliently bendable, to a limited extent, into different concave and/or convex cylindrical curvatures about a particular axis and second means acting on the first means for adjustably bending the light reflecting surface into a particular selected one of the different curvatures depending upon the astigmatism to be corrected for and for fixedly maintaining the curvature selected. In the embodiment disclosed, the light reflecting surface is adjustably bendable into the selected cylindrical curvature by application of a particular bending moment to the reinforced side edges of the light reflecting surface.
Further SEASAT SAR coastal ocean wave analysis
NASA Technical Reports Server (NTRS)
Kasischke, E. S.; Shuchman, R. A.; Meadows, G. A.; Jackson, P. L.; Tseng, Y.
1981-01-01
Analysis techniques used to exploit SEASAT synthetic aperture radar (SAR) data of gravity waves are discussed and the SEASAT SAR's ability to monitor large scale variations in gravity wave fields in both deep and shallow water is evaluated. The SAR analysis techniques investigated included motion compensation adjustments and the semicausal model for spectral analysis of SAR wave data. It was determined that spectra generated from fast Fourier transform analysis (FFT) of SAR wave data were not significantly altered when either range telerotation adjustments or azimuth focus shifts were used during processing of the SAR signal histories, indicating that SEASAT imagery of gravity waves is not significantly improved or degraded by motion compensation adjustments. Evaluation of the semicausal (SC) model using SEASAT SAR data from Rev. 974 indicates that the SC spectral estimates were not significantly better than the FFT results.
Combinative Particle Size Reduction Technologies for the Production of Drug Nanocrystals
Salazar, Jaime; Müller, Rainer H.; Möschwitzer, Jan P.
2014-01-01
Nanosizing is a suitable method to enhance the dissolution rate and therefore the bioavailability of poorly soluble drugs. The success of the particle size reduction processes depends on critical factors such as the employed technology, equipment, and drug physicochemical properties. High pressure homogenization and wet bead milling are standard comminution techniques that have been already employed to successfully formulate poorly soluble drugs and bring them to market. However, these techniques have limitations in their particle size reduction performance, such as long production times and the necessity of employing a micronized drug as the starting material. This review article discusses the development of combinative methods, such as the NANOEDGE, H 96, H 69, H 42, and CT technologies. These processes were developed to improve the particle size reduction effectiveness of the standard techniques. These novel technologies can combine bottom-up and/or top-down techniques in a two-step process. The combinative processes lead in general to improved particle size reduction effectiveness. Faster production of drug nanocrystals and smaller final mean particle sizes are among the main advantages. The combinative particle size reduction technologies are very useful formulation tools, and they will continue acquiring importance for the production of drug nanocrystals. PMID:26556191
Correlation analysis of fracture arrangement in space
NASA Astrophysics Data System (ADS)
Marrett, Randall; Gale, Julia F. W.; Gómez, Leonel A.; Laubach, Stephen E.
2018-03-01
We present new techniques that overcome limitations of standard approaches to documenting spatial arrangement. The new techniques directly quantify spatial arrangement by normalizing to expected values for randomly arranged fractures. The techniques differ in terms of computational intensity, robustness of results, ability to detect anti-correlation, and use of fracture size data. Variation of spatial arrangement across a broad range of length scales facilitates distinguishing clustered and periodic arrangements-opposite forms of organization-from random arrangements. Moreover, self-organized arrangements can be distinguished from arrangements due to extrinsic organization. Traditional techniques for analysis of fracture spacing are hamstrung because they account neither for the sequence of fracture spacings nor for possible coordination between fracture size and position, attributes accounted for by our methods. All of the new techniques reveal fractal clustering in a test case of veins, or cement-filled opening-mode fractures, in Pennsylvanian Marble Falls Limestone. The observed arrangement is readily distinguishable from random and periodic arrangements. Comparison of results that account for fracture size with results that ignore fracture size demonstrates that spatial arrangement is dominated by the sequence of fracture spacings, rather than coordination of fracture size with position. Fracture size and position are not completely independent in this example, however, because large fractures are more clustered than small fractures. Both spatial and size organization of veins here probably emerged from fracture interaction during growth. The new approaches described here, along with freely available software to implement the techniques, can be applied with effect to a wide range of structures, or indeed many other phenomena such as drilling response, where spatial heterogeneity is an issue.
Holmes, W J M; Timmons, M J; Kauser, S
2015-10-01
Techniques used to estimate implant size for primary breast augmentation have evolved since the 1970s. Currently no consensus exists on the optimal method to select implant size for primary breast augmentation. In 2013 we asked United Kingdom consultant plastic surgeons who were full members of BAPRAS or BAAPS what was their technique for implant size selection for primary aesthetic breast augmentation. We also asked what was the range of implant sizes they commonly used. The answers to question one were grouped into four categories: experience, measurements, pre-operative external sizers and intra-operative sizers. The response rate was 46% (164/358). Overall, 95% (153/159) of all respondents performed some form of pre-operative assessment, the others relied on "experience" only. The most common technique for pre-operative assessment was by external sizers (74%). Measurements were used by 57% of respondents and 3% used intra-operative sizers only. A combination of measurements and sizers was used by 34% of respondents. The most common measurements were breast base (68%), breast tissue compliance (19%), breast height (15%), and chest diameter (9%). The median implant size commonly used in primary breast augmentation was 300cc. Pre-operative external sizers are the most common technique used by UK consultant plastic surgeons to select implant size for primary breast augmentation. We discuss the above findings in relation to the evolution of pre-operative planning techniques for breast augmentation. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Ludvigsson, Linus; Isaxon, Christina; Nilsson, Patrik T; Tinnerberg, Hakan; Messing, Maria E; Rissler, Jenny; Skaug, Vidar; Gudmundsson, Anders; Bohgard, Mats; Hedmer, Maria; Pagels, Joakim
2016-05-01
An increased production and use of carbon nanotubes (CNTs) is occurring worldwide. In parallel, a growing concern is emerging on the adverse effects the unintentional inhalation of CNTs can have on humans. There is currently a debate regarding which exposure metrics and measurement strategies are the most relevant to investigate workplace exposures to CNTs. This study investigated workplace CNT emissions using a combination of time-integrated filter sampling for scanning electron microscopy (SEM) and direct reading aerosol instruments (DRIs). Field measurements were performed during small-scale manufacturing of multiwalled carbon nanotubes using the arc discharge technique. Measurements with highly time- and size-resolved DRI techniques were carried out both in the emission and background (far-field) zones. Novel classifications and counting criteria were set up for the SEM method. Three classes of CNT-containing particles were defined: type 1: particles with aspect ratio length:width >3:1 (fibrous particles); type 2: particles without fibre characteristics but with high CNT content; and type 3: particles with visible embedded CNTs. Offline sampling using SEM showed emissions of CNT-containing particles in 5 out of 11 work tasks. The particles were classified into the three classes, of which type 1, fibrous CNT particles contributed 37%. The concentration of all CNT-containing particles and the occurrence of the particle classes varied strongly between work tasks. Based on the emission measurements, it was assessed that more than 85% of the exposure originated from open handling of CNT powder during the Sieving, mechanical work-up, and packaging work task. The DRI measurements provided complementary information, which combined with SEM provided information on: (i) the background adjusted emission concentration from each work task in different particle size ranges, (ii) identification of the key procedures in each work task that lead to emission peaks, (iii) identification of emission events that affect the background, thereby leading to far-field exposure risks for workers other than the operator of the work task, and (iv) the fraction of particles emitted from each source that contains CNTs. There is an urgent need for a standardized/harmonized method for electron microscopy (EM) analysis of CNTs. The SEM method developed in this study can form the basis for such a harmonized protocol for the counting of CNTs. The size-resolved DRI techniques are commonly not specific enough to selective analysis of CNT-containing particles and thus cannot yet replace offline time-integrated filter sampling followed by SEM. A combination of EM and DRI techniques offers the most complete characterization of workplace emissions of CNTs today. © The Author 2016. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
CT of Patients With Hip Fracture: Muscle Size and Attenuation Help Predict Mortality
Boutin, Robert D.; Bamrungchart, Sara; Bateni, Cyrus P.; Beavers, Daniel P.; Beavers, Kristen M.; Meehan, John P.; Lenchik, Leon
2018-01-01
OBJECTIVE Our objective was to determine the association between muscle cross-sectional area and attenuation, as measured on routine CT scans, and mortality in older patients with hip fracture. MATERIALS AND METHODS A retrospective 10-year study of patients with hip fracture was conducted with the following inclusion criteria: age 65 years or older, first-time hip fracture treated with surgery, and CT of the chest, abdomen, or pelvis. This yielded 274 patients (70.4% women; mean [± SD] age, 81.3 ± 8.3 years). On each CT scan, two readers independently measured the size (cross-sectional area, indexed for patient height) and attenuation of the paravertebral muscle at T12 and the psoas muscle at L4. We then determined the association between overall mortality and the muscle size and muscle attenuation, while adjusting for demographic variables (age, sex, ethnicity, and body mass index), American Society of Anesthesiologists (ASA) classification, and Charlson comorbidity index (CCI). RESULTS The overall mortality rate increased from 28.3% at 1 year to 79.5% at 5 years. Mortality was associated with decreased thoracic muscle size (odds ratio [OR], 0.66; 95% CI, 0.49–0.87). This association persisted after adjusting for demographic variables (OR, 0.69; 95% CI, 0.50–0.95), the ASA classification (OR, 0.70; CI, 0.51–0.97), and the CCI (OR, 0.72; 95% CI, 0.52–1.00). Similarly, decreased survival was associated with decreased thoracic muscle attenuation after adjusting for all of these combinations of covariates (OR, 0.67–0.72; 95% CI, 0.49–0.99). Decreased lumbar muscle size and attenuation trended with decreased survival but did not reach statistical significance. CONCLUSION In older adults with hip fractures, CT findings of decreased thoracic paravertebral muscle size and attenuation are associated with decreased overall survival. PMID:28267356
Broberg, Per
2013-07-19
One major concern with adaptive designs, such as the sample size adjustable designs, has been the fear of inflating the type I error rate. In (Stat Med 23:1023-1038, 2004) it is however proven that when observations follow a normal distribution and the interim result show promise, meaning that the conditional power exceeds 50%, type I error rate is protected. This bound and the distributional assumptions may seem to impose undesirable restrictions on the use of these designs. In (Stat Med 30:3267-3284, 2011) the possibility of going below 50% is explored and a region that permits an increased sample size without inflation is defined in terms of the conditional power at the interim. A criterion which is implicit in (Stat Med 30:3267-3284, 2011) is derived by elementary methods and expressed in terms of the test statistic at the interim to simplify practical use. Mathematical and computational details concerning this criterion are exhibited. Under very general conditions the type I error rate is preserved under sample size adjustable schemes that permit a raise. The main result states that for normally distributed observations raising the sample size when the result looks promising, where the definition of promising depends on the amount of knowledge gathered so far, guarantees the protection of the type I error rate. Also, in the many situations where the test statistic approximately follows a normal law, the deviation from the main result remains negligible. This article provides details regarding the Weibull and binomial distributions and indicates how one may approach these distributions within the current setting. There is thus reason to consider such designs more often, since they offer a means of adjusting an important design feature at little or no cost in terms of error rate.
Mapping osmotic adjustment in an advanced back-cross inbred population of rice.
Robin, S; Pathan, M S; Courtois, B; Lafitte, R; Carandang, S; Lanceras, S; Amante, M; Nguyen, H T; Li, Z
2003-11-01
Osmotic adjustment is one of several characters putatively associated with drought tolerance in rice. Indica cultivars are known to have a greater capacity for osmotic adjustment than japonica cultivars. We developed an advanced back-cross population using an indica donor, IR62266-42-6-2, to introgress osmotic adjustment into an elite japonica cultivar, IR60080-46A. One hundred and fifty BC(3)F(3) families were genotyped using microsatellites and RFLP markers, and a few candidate genes. We evaluated osmotic adjustment in these lines under greenhouse conditions using the re-hydration technique. Using the composite interval mapping technique, we detected 14 QTLs located on chromosomes 1, 2, 3, 4, 5, 7, 8 and 10 that together explained 58% of the phenotypic variability. Most, but not all, of the alleles with positive effects came from the donor parent. On chromosome 8, two QTLs were associated in repulsion. The QTL locations were in good agreement with previous studies on this trait on rice and in other cereals. Some BC(3)F(3) lines carried the favorable alleles at the two markers flanking up to four QTLs. Intercrossing these lines followed by marker-aided selection in their progenies will be necessary to recover lines with levels of osmotic adjustment equal to the donor parent. The advanced back-cross strategy appeared to be an appropriate method to accelerate the process of introgressing interesting traits into elite material.
Internet-Based Self-Help Intervention for ICD-11 Adjustment Disorder: Preliminary Findings.
Eimontas, Jonas; Rimsaite, Zivile; Gegieckaite, Goda; Zelviene, Paulina; Kazlauskas, Evaldas
2018-06-01
Adjustment disorder is one of the most diagnosed mental disorders. However, there is a lack of studies of specialized internet-based psychosocial interventions for adjustment disorder. We aimed to analyze the outcomes of an internet-based unguided self-help psychosocial intervention BADI for adjustment disorder in a two armed randomized controlled trial with a waiting list control group. In total 284 adult participants were randomized in this study. We measured adjustment disorder as a primary outcome, and psychological well-being as a secondary outcome at pre-intervention (T1) and one month after the intervention (T2). We found medium effect size of the intervention for the completer sample on adjustment disorder symptoms. Intervention was effective for those participants who used it at least one time in 30-day period. Our results revealed the potential of unguided internet-based self-help intervention for adjustment disorder. However, high dropout rates in the study limits the generalization of the outcomes of the intervention only to completers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
He, Qing, E-mail: hqng@163.com; Mao, Xinhua, E-mail: 30400414@qq.com; Chu, Dongliang, E-mail: 569256386@qq.com
This study proposes an optimized frequency adjustment method that uses a micro-cantilever beam-based piezoelectric vibration generator based on a combination of added mass and capacitance. The most important concept of the proposed method is that the frequency adjustment process is divided into two steps: the first is a rough adjustment step that changes the size of the mass added at the end of cantilever to adjust the frequency in a large-scale and discontinuous manner; the second step is a continuous but short-range frequency adjustment via the adjustable added capacitance. Experimental results show that when the initial natural frequency of amore » micro piezoelectric vibration generator is 69.8 Hz, then this natural frequency can be adjusted to any value in the range from 54.2 Hz to 42.1 Hz using the combination of the added mass and the capacitance. This method simply and effectively matches a piezoelectric vibration generator’s natural frequency to the vibration source frequency.« less
PID feedback controller used as a tactical asset allocation technique: The G.A.M. model
NASA Astrophysics Data System (ADS)
Gandolfi, G.; Sabatini, A.; Rossolini, M.
2007-09-01
The objective of this paper is to illustrate a tactical asset allocation technique utilizing the PID controller. The proportional-integral-derivative (PID) controller is widely applied in most industrial processes; it has been successfully used for over 50 years and it is used by more than 95% of the plants processes. It is a robust and easily understood algorithm that can provide excellent control performance in spite of the diverse dynamic characteristics of the process plant. In finance, the process plant, controlled by the PID controller, can be represented by financial market assets forming a portfolio. More specifically, in the present work, the plant is represented by a risk-adjusted return variable. Money and portfolio managers’ main target is to achieve a relevant risk-adjusted return in their managing activities. In literature and in the financial industry business, numerous kinds of return/risk ratios are commonly studied and used. The aim of this work is to perform a tactical asset allocation technique consisting in the optimization of risk adjusted return by means of asset allocation methodologies based on the PID model-free feedback control modeling procedure. The process plant does not need to be mathematically modeled: the PID control action lies in altering the portfolio asset weights, according to the PID algorithm and its parameters, Ziegler-and-Nichols-tuned, in order to approach the desired portfolio risk-adjusted return efficiently.
Thomas E. Lisle; Jonathan M. Nelson; John Pitlick; Mary Ann Madej; Brent L. Barkett
2000-01-01
Abstract - Local variations in boundary shear stress acting on bed-surface particles control patterns of bed load transport and channel evolution during varying stream discharges. At the reach scale a channel adjusts to imposed water and sediment supply through mutual interactions among channel form, local grain size, and local flow dynamics that govern bed mobility...
75 FR 82217 - Community Reinvestment Act Regulations
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-30
...The OCC, the Board, the FDIC, and the OTS (collectively, the ``agencies'') are amending their Community Reinvestment Act (CRA) regulations to adjust the asset-size thresholds used to define ``small bank'' or ``small savings association'' and ``intermediate small bank'' or ``intermediate small savings association.'' As required by the CRA regulations, the adjustment to the threshold amount is based on the annual percentage change in the Consumer Price Index.
76 FR 79529 - Community Reinvestment Act Regulations
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-22
...The OCC, the Board, and the FDIC (collectively, the ``agencies'') are amending their Community Reinvestment Act (CRA) regulations to adjust the asset-size thresholds used to define ``small bank'' or ``small savings association'' and ``intermediate small bank'' or ``intermediate small savings association.'' As required by the CRA regulations, the adjustment to the threshold amount is based on the annual percentage change in the Consumer Price Index.
Analysis of Size Correlations for Microdroplets Produced by Ultrasonic Atomization
Barba, Anna Angela; d'Amore, Matteo
2013-01-01
Microencapsulation techniques are widely applied in the field of pharmaceutical production to control drugs release in time and in physiological environments. Ultrasonic-assisted atomization is a new technique to produce microencapsulated systems by a mechanical approach. Interest in this technique is due to the advantages evidenceable (low level of mechanical stress in materials, reduced energy request, reduced apparatuses size) when comparing it to more conventional techniques. In this paper, the groundwork of atomization is introduced, the role of relevant parameters in ultrasonic atomization mechanism is discussed, and correlations to predict droplets size starting from process parameters and material properties are presented and tested. PMID:24501580
Inversion of particle-size distribution from angular light-scattering data with genetic algorithms.
Ye, M; Wang, S; Lu, Y; Hu, T; Zhu, Z; Xu, Y
1999-04-20
A stochastic inverse technique based on a genetic algorithm (GA) to invert particle-size distribution from angular light-scattering data is developed. This inverse technique is independent of any given a priori information of particle-size distribution. Numerical tests show that this technique can be successfully applied to inverse problems with high stability in the presence of random noise and low susceptibility to the shape of distributions. It has also been shown that the GA-based inverse technique is more efficient in use of computing time than the inverse Monte Carlo method recently developed by Ligon et al. [Appl. Opt. 35, 4297 (1996)].
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huber, Franz J. T.; Will, Stefan, E-mail: stefan.will@fau.de; Erlangen Graduate School in Advanced Optical Technologies
A mobile demonstrator for the comprehensive online-characterization of gas-borne nanoparticle aggregates is presented. Two optical measurement techniques are combined, both utilizing a pulsed Nd:YAG laser as light source. Aggregate size and fractal dimension are measured by Wide-Angle Light Scattering (WALS). An ellipsoidal mirror images elastically scattered light from scattering angles between 10° and 165° onto a CCD-camera chip resulting in an almost complete scattering diagram with high angular resolution. Primary particle size and volume fraction are measured by time-resolved Laser-Induced Incandescence (TiRe-LII). Here, particles are heated up to about 3000 K by the short laser pulse, the enhanced thermal radiationmore » signal is detected with gated photomultiplier tubes. Analysis of the signal decay time and maximum LII-signal allows for the determination of primary particle diameter and volume fraction. The performance of the system is demonstrated by combined measurements on soot nanoparticle aggregates from a soot aerosol generator. Particle and aggregate sizes are varied by using different equivalence ratios of the combustion in the generator. Soot volume fraction can be adjusted by different levels of dilution with air. Online-measurements were carried out demonstrating the favorable performance of the system and the potential for industrial applications such as process control and product development. The particle properties obtained are confirmed through transmission electron microscopy analysis on representative samples.« less
The financial burden of reexcising incompletely excised soft tissue sarcomas: a cost analysis.
Alamanda, Vignesh K; Delisca, Gadini O; Mathis, Shannon L; Archer, Kristin R; Ehrenfeld, Jesse M; Miller, Mark W; Homlar, Kelly C; Halpern, Jennifer L; Schwartz, Herbert S; Holt, Ginger E
2013-09-01
Although survival outcomes have been evaluated between those undergoing a planned primary excision and those undergoing a reexcision following an unplanned resection, the financial implications associated with a reexcision have yet to be elucidated. A query for financial data (professional, technical, indirect charges) for soft tissue sarcoma excisions from 2005 to 2008 was performed. A total of 304 patients (200 primary excisions and 104 reexcisions) were identified. Wilcoxon rank sum tests and χ2 or Fisher's exact tests were used to compare differences in demographics and tumor characteristics. Multivariable linear regression analyses were performed with bootstrapping techniques. The average professional charge for a primary excision was $9,694 and $12,896 for a reexcision (p<.001). After adjusting for tumor size, American Society of Anesthesiologists status, grade, and site, patients undergoing reexcision saw an increase of $3,699 in professional charges more than those with a primary excision (p<.001). Although every 1-cm increase in size of the tumor results in an increase of $148 for a primary excision (p=.006), size was not an independent factor in affecting reexcision charges. The grade of the tumor was positively associated with professional charges of both groups such that higher-grade tumors resulted in higher charges compared to lower-grade tumors (p<.05). Reexcision of an incompletely excised sarcoma results in significantly higher professional charges when compared to a single, planned complete excision. Additionally, when the cost of the primary unplanned surgery is considered, the financial burden nearly doubles.
Huber, Franz J T; Altenhoff, Michael; Will, Stefan
2016-05-01
A mobile demonstrator for the comprehensive online-characterization of gas-borne nanoparticle aggregates is presented. Two optical measurement techniques are combined, both utilizing a pulsed Nd:YAG laser as light source. Aggregate size and fractal dimension are measured by Wide-Angle Light Scattering (WALS). An ellipsoidal mirror images elastically scattered light from scattering angles between 10° and 165° onto a CCD-camera chip resulting in an almost complete scattering diagram with high angular resolution. Primary particle size and volume fraction are measured by time-resolved Laser-Induced Incandescence (TiRe-LII). Here, particles are heated up to about 3000 K by the short laser pulse, the enhanced thermal radiation signal is detected with gated photomultiplier tubes. Analysis of the signal decay time and maximum LII-signal allows for the determination of primary particle diameter and volume fraction. The performance of the system is demonstrated by combined measurements on soot nanoparticle aggregates from a soot aerosol generator. Particle and aggregate sizes are varied by using different equivalence ratios of the combustion in the generator. Soot volume fraction can be adjusted by different levels of dilution with air. Online-measurements were carried out demonstrating the favorable performance of the system and the potential for industrial applications such as process control and product development. The particle properties obtained are confirmed through transmission electron microscopy analysis on representative samples.
NASA Astrophysics Data System (ADS)
Huber, Franz J. T.; Altenhoff, Michael; Will, Stefan
2016-05-01
A mobile demonstrator for the comprehensive online-characterization of gas-borne nanoparticle aggregates is presented. Two optical measurement techniques are combined, both utilizing a pulsed Nd:YAG laser as light source. Aggregate size and fractal dimension are measured by Wide-Angle Light Scattering (WALS). An ellipsoidal mirror images elastically scattered light from scattering angles between 10° and 165° onto a CCD-camera chip resulting in an almost complete scattering diagram with high angular resolution. Primary particle size and volume fraction are measured by time-resolved Laser-Induced Incandescence (TiRe-LII). Here, particles are heated up to about 3000 K by the short laser pulse, the enhanced thermal radiation signal is detected with gated photomultiplier tubes. Analysis of the signal decay time and maximum LII-signal allows for the determination of primary particle diameter and volume fraction. The performance of the system is demonstrated by combined measurements on soot nanoparticle aggregates from a soot aerosol generator. Particle and aggregate sizes are varied by using different equivalence ratios of the combustion in the generator. Soot volume fraction can be adjusted by different levels of dilution with air. Online-measurements were carried out demonstrating the favorable performance of the system and the potential for industrial applications such as process control and product development. The particle properties obtained are confirmed through transmission electron microscopy analysis on representative samples.
Ultrasound based computer-aided-diagnosis of kidneys for pediatric hydronephrosis
NASA Astrophysics Data System (ADS)
Cerrolaza, Juan J.; Peters, Craig A.; Martin, Aaron D.; Myers, Emmarie; Safdar, Nabile; Linguraru, Marius G.
2014-03-01
Ultrasound is the mainstay of imaging for pediatric hydronephrosis, though its potential as diagnostic tool is limited by its subjective assessment, and lack of correlation with renal function. Therefore, all cases showing signs of hydronephrosis undergo further invasive studies, like diuretic renogram, in order to assess the actual renal function. Under the hypothesis that renal morphology is correlated with renal function, a new ultrasound based computer-aided diagnosis (CAD) tool for pediatric hydronephrosis is presented. From 2D ultrasound, a novel set of morphological features of the renal collecting systems and the parenchyma, is automatically extracted using image analysis techniques. From the original set of features, including size, geometric and curvature descriptors, a subset of ten features are selected as predictive variables, combining a feature selection technique and area under the curve filtering. Using the washout half time (T1/2) as indicative of renal obstruction, two groups are defined. Those cases whose T1/2 is above 30 minutes are considered to be severe, while the rest would be in the safety zone, where diuretic renography could be avoided. Two different classification techniques are evaluated (logistic regression, and support vector machines). Adjusting the probability decision thresholds to operate at the point of maximum sensitivity, i.e., preventing any severe case be misclassified, specificities of 53%, and 75% are achieved, for the logistic regression and the support vector machine classifier, respectively. The proposed CAD system allows to establish a link between non-invasive non-ionizing imaging techniques and renal function, limiting the need for invasive and ionizing diuretic renography.
Determination of macular hole size in relation to individual variabilities of fovea morphology.
Shin, J Y; Chu, Y K; Hong, Y T; Kwon, O W; Byeon, S H
2015-08-01
To determine the preoperative anatomic factors in macular holes and their correlation to hole closure. Forty-six eyes with consecutive unilateral macular hole who had undergone surgery and followed up for at least 6 months were enrolled. Optical coherence tomography images and best-corrected visual acuity (BCVA) within 2 weeks prior to operation and 6 months after surgery were analyzed. The maximal hole dimension, foveal degeneration factors (inner nuclear layer cysts, outer segment (OS) shortening) and the widest foveolar floor size of the fellow eyes were measured. For overcoming preoperative individual variability of foveal morphology, an 'adjusted' hole size parameter (the ratio between the hole size and the fellow eye foveolar floor size) was used based on the fact that both eyes were morphologically symmetrical. Mean preoperative BCVA (logMAR) was 1.03±0.43 and the mean postoperative BCVA was 0.50±0.38 at 6 months. Preoperative BCVA is significantly associated with postoperative BCVA (P=0.0002). The average hole diameter was 448.9±196.8 μm and the average fellow eye foveolar floor size was 461.3±128.4 μm. There was a correlation between hole diameter and the size of the fellow eye foveolar floor (Pearson's coefficient=0.608, P<0.0001). The adjusted hole size parameter was 0.979±0.358 (0.761-2.336), which was a strong predictor for both anatomic (P=0.0281) and visual (P=0.0016) outcome. When determining the extent of preoperative hole size, we have to take into consideration the foveal morphologic variations among individuals. Hole size may be related to the original foveal shape, especially in relation to the centrifugal retraction of the foveal tissues.
Ezoe, Satoshi; Morooka, Takeo; Noda, Tatsuya; Sabin, Miriam Lewis; Koike, Soichi
2012-01-01
Men who have sex with men (MSM) are one of the groups most at risk for HIV infection in Japan. However, size estimates of MSM populations have not been conducted with sufficient frequency and rigor because of the difficulty, high cost and stigma associated with reaching such populations. This study examined an innovative and simple method for estimating the size of the MSM population in Japan. We combined an internet survey with the network scale-up method, a social network method for estimating the size of hard-to-reach populations, for the first time in Japan. An internet survey was conducted among 1,500 internet users who registered with a nationwide internet-research agency. The survey participants were asked how many members of particular groups with known population sizes (firepersons, police officers, and military personnel) they knew as acquaintances. The participants were also asked to identify the number of their acquaintances whom they understood to be MSM. Using these survey results with the network scale-up method, the personal network size and MSM population size were estimated. The personal network size was estimated to be 363.5 regardless of the sex of the acquaintances and 174.0 for only male acquaintances. The estimated MSM prevalence among the total male population in Japan was 0.0402% without adjustment, and 2.87% after adjusting for the transmission error of MSM. The estimated personal network size and MSM prevalence seen in this study were comparable to those from previous survey results based on the direct-estimation method. Estimating population sizes through combining an internet survey with the network scale-up method appeared to be an effective method from the perspectives of rapidity, simplicity, and low cost as compared with more-conventional methods.
Regression Analysis of Optical Coherence Tomography Disc Variables for Glaucoma Diagnosis.
Richter, Grace M; Zhang, Xinbo; Tan, Ou; Francis, Brian A; Chopra, Vikas; Greenfield, David S; Varma, Rohit; Schuman, Joel S; Huang, David
2016-08-01
To report diagnostic accuracy of optical coherence tomography (OCT) disc variables using both time-domain (TD) and Fourier-domain (FD) OCT, and to improve the use of OCT disc variable measurements for glaucoma diagnosis through regression analyses that adjust for optic disc size and axial length-based magnification error. Observational, cross-sectional. In total, 180 normal eyes of 112 participants and 180 eyes of 138 participants with perimetric glaucoma from the Advanced Imaging for Glaucoma Study. Diagnostic variables evaluated from TD-OCT and FD-OCT were: disc area, rim area, rim volume, optic nerve head volume, vertical cup-to-disc ratio (CDR), and horizontal CDR. These were compared with overall retinal nerve fiber layer thickness and ganglion cell complex. Regression analyses were performed that corrected for optic disc size and axial length. Area-under-receiver-operating curves (AUROC) were used to assess diagnostic accuracy before and after the adjustments. An index based on multiple logistic regression that combined optic disc variables with axial length was also explored with the aim of improving diagnostic accuracy of disc variables. Comparison of diagnostic accuracy of disc variables, as measured by AUROC. The unadjusted disc variables with the highest diagnostic accuracies were: rim volume for TD-OCT (AUROC=0.864) and vertical CDR (AUROC=0.874) for FD-OCT. Magnification correction significantly worsened diagnostic accuracy for rim variables, and while optic disc size adjustments partially restored diagnostic accuracy, the adjusted AUROCs were still lower. Axial length adjustments to disc variables in the form of multiple logistic regression indices led to a slight but insignificant improvement in diagnostic accuracy. Our various regression approaches were not able to significantly improve disc-based OCT glaucoma diagnosis. However, disc rim area and vertical CDR had very high diagnostic accuracy, and these disc variables can serve to complement additional OCT measurements for diagnosis of glaucoma.
Haider, Adil H; Saleem, Taimur; Leow, Jeffrey J; Villegas, Cassandra V; Kisat, Mehreen; Schneider, Eric B; Haut, Elliott R; Stevens, Kent A; Cornwell, Edward E; MacKenzie, Ellen J; Efron, David T
2012-05-01
Risk-adjusted analyses are critical in evaluating trauma outcomes. The National Trauma Data Bank (NTDB) is a statistically robust registry that allows such analyses; however, analytical techniques are not yet standardized. In this study, we examined peer-reviewed manuscripts published using NTDB data, with particular attention to characteristics strongly associated with trauma outcomes. Our objective was to determine if there are substantial variations in the methodology and quality of risk-adjusted analyses and therefore, whether development of best practices for risk-adjusted analyses is warranted. A database of all studies using NTDB data published through December 2010 was created by searching PubMed and Embase. Studies with multivariate risk-adjusted analyses were examined for their central question, main outcomes measures, analytical techniques, covariates in adjusted analyses, and handling of missing data. Of 286 NTDB publications, 122 performed a multivariable adjusted analysis. These studies focused on clinical outcomes (51 studies), public health policy or injury prevention (30), quality (16), disparities (15), trauma center designation (6), or scoring systems (4). Mortality was the main outcome in 98 of these studies. There were considerable differences in the covariates used for case adjustment. The 3 covariates most frequently controlled for were age (95%), Injury Severity Score (85%), and sex (78%). Up to 43% of studies did not control for the 5 basic covariates necessary to conduct a risk-adjusted analysis of trauma mortality. Less than 10% of studies used clustering to adjust for facility differences or imputation to handle missing data. There is significant variability in how risk-adjusted analyses using data from the NTDB are performed. Best practices are needed to further improve the quality of research from the NTDB. Copyright © 2012 American College of Surgeons. Published by Elsevier Inc. All rights reserved.
Parenting and Late Adolescent Emotional Adjustment: Mediating Effects of Discipline and Gender
ERIC Educational Resources Information Center
McKinney, Cliff; Milone, Mary Catherine; Renk, Kimberly
2011-01-01
Research suggests that parenting styles are related to the types of discipline parents utilize and that the coupling of parenting styles and discipline techniques are related to child outcomes. Although extant research examines the effects of parenting styles and discipline on child and early adolescent adjustment, less is known about adjustment…
Dispersion Polymerization of Polystyrene Particles Using Alcohol as Reaction Medium
NASA Astrophysics Data System (ADS)
Cho, Young-Sang; Shin, Cheol Hwan; Han, Sujin
2016-02-01
In this study, monodisperse polystyrene nanospheres were prepared by dispersion polymerization using alcohol as reaction medium to prepare colloidal clusters of the latex beads. Polyvinylpyrrolidone (PVP) and 2-(methacryloyloxy)ethyltrimethylammonium chloride (MTC) were used as dispersion stabilizer and comonomer, respectively. The particle size could be controlled by adjusting the reactant compositions such as the amount of stabilizer, comonomer, and water in the reactant mixture. The size and monodispersity of the polymeric particles could be also controlled by changing the reaction medium with different alcohols other than ethanol or adjusting the polymerization temperature. The synthesized particles could be self-organized inside water-in-oil emulsion droplets by evaporation-driven self-assembly to produce colloidal clusters of the polymeric nanospheres.
Mesh control information of windmill designed by Solidwork program
NASA Astrophysics Data System (ADS)
Mulyana, T.; Sebayang, D.; Rafsanjani, A. M. D.; Adani, J. H. D.; Muhyiddin, Y. S.
2017-12-01
This paper presents the mesh control information imposed on the windmill already designed. The accuracy of Simulation results is influenced by the quality of the created mesh. However, compared to the quality of the mesh is made, the simulation time running will be done software also increases. The smaller the size of the elements created when making the mesh, the better the mesh quality will be generated. When adjusting the mesh size, there is a slider that acts as the density regulator of the element. SolidWorks Simulation also has Mesh Control facility. Features that can adjust mesh density only in the desired part. The best results of mesh control obtained for both static and thermal simulation have ratio 1.5.
Learn, R; Feigenbaum, E
2016-06-01
Two algorithms that enhance the utility of the absorbing boundary layer are presented, mainly in the framework of the Fourier beam-propagation method. One is an automated boundary layer width selector that chooses a near-optimal boundary size based on the initial beam shape. The second algorithm adjusts the propagation step sizes based on the beam shape at the beginning of each step in order to reduce aliasing artifacts.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Learn, R.; Feigenbaum, E.
Two algorithms that enhance the utility of the absorbing boundary layer are presented, mainly in the framework of the Fourier beam-propagation method. One is an automated boundary layer width selector that chooses a near-optimal boundary size based on the initial beam shape. Furthermore, the second algorithm adjusts the propagation step sizes based on the beam shape at the beginning of each step in order to reduce aliasing artifacts.
Learn, R.; Feigenbaum, E.
2016-05-27
Two algorithms that enhance the utility of the absorbing boundary layer are presented, mainly in the framework of the Fourier beam-propagation method. One is an automated boundary layer width selector that chooses a near-optimal boundary size based on the initial beam shape. Furthermore, the second algorithm adjusts the propagation step sizes based on the beam shape at the beginning of each step in order to reduce aliasing artifacts.
Production of stocker-size hybrid tilapia in an outdoor biofloc production system
USDA-ARS?s Scientific Manuscript database
Production efficiency per unit volume of water can be improved when stocking rate is adjusted to allow rapid growth of the culture organism to the desired target weight. Fingerlings often are grown to stocker size (ca. 100-150 g/fish) at high stocking rates and then the population is thinned to allo...
Hallén, Jonas; Jensen, Jesper K; Buser, Peter; Jaffe, Allan S; Atar, Dan
2011-03-01
Presence of microvascular obstruction (MVO) following primary percutaneous coronary intervention (pPCI) for ST-elevation myocardial infarction (STEMI) confers higher risk of left-ventricular remodelling and dysfunction. Measurement of cardiac troponin I (cTnI) after STEMI reflects the extent of myocardial destruction. We aimed to explore whether cTnI values were associated with presence of MVO independently of infarct size in STEMI patients receiving pPCI. 175 patients with STEMI were included. cTnI was sampled at 24 and 48 h. MVO and infarct size was determined by delayed enhancement with cardiac magnetic resonance at five to seven days post index event. The presence of MVO following STEMI was associated with larger infarct size and higher values of cTnI at 24 and 48 h. For any given infarct size or cTnI value, there was a greater risk of MVO development in non-anterior infarctions. cTnI was strongly associated with MVO in both anterior and non-anterior infarctions (P < 0.01) after adjustment for covariates (including infarct size); and was reasonably effective in predicting MVO in individual patients (area-under-the-curve ≥0.81). Presence of MVO is reflected in levels of cTnI sampled at an early time-point following STEMI and this association persists after adjustment for infarct size.
Overall, John E; Tonidandel, Scott; Starbuck, Robert R
2006-01-01
Recent contributions to the statistical literature have provided elegant model-based solutions to the problem of estimating sample sizes for testing the significance of differences in mean rates of change across repeated measures in controlled longitudinal studies with differentially correlated error and missing data due to dropouts. However, the mathematical complexity and model specificity of these solutions make them generally inaccessible to most applied researchers who actually design and undertake treatment evaluation research in psychiatry. In contrast, this article relies on a simple two-stage analysis in which dropout-weighted slope coefficients fitted to the available repeated measurements for each subject separately serve as the dependent variable for a familiar ANCOVA test of significance for differences in mean rates of change. This article is about how a sample of size that is estimated or calculated to provide desired power for testing that hypothesis without considering dropouts can be adjusted appropriately to take dropouts into account. Empirical results support the conclusion that, whatever reasonable level of power would be provided by a given sample size in the absence of dropouts, essentially the same power can be realized in the presence of dropouts simply by adding to the original dropout-free sample size the number of subjects who would be expected to drop from a sample of that original size under conditions of the proposed study.
Analyses of Inhomogeneities in Radiosonde Temperature and Humidity Time Series.
NASA Astrophysics Data System (ADS)
Zhai, Panmao; Eskridge, Robert E.
1996-04-01
Twice daily radiosonde data from selected stations in the United States (period 1948 to 1990) and China (period 1958 to 1990) were sorted into time series. These stations have one sounding taken in darkness and the other in sunlight. The analysis shows that the 0000 and 1200 UTC time series are highly correlated. Therefore, the Easterling and Peterson technique was tested on the 0000 and 1200 time series to detect inhomogeneities and to estimate the size of the biases. Discontinuities were detected using the difference series created from the 0000 and 1200 UTC time series. To establish that the detected bias was significant, a t test was performed to confirm that the change occurs in the daytime series but not in the nighttime series.Both U.S. and Chinese radiosonde temperature and humidity data include inhomogeneities caused by changes in radiosonde sensors and observation times. The U.S. humidity data have inhomogeneities that were caused by instrument changes and the censoring of data. The practice of reporting relative humidity as 19% when it is lower than 20% or the temperature is below 40°C is called censoring. This combination of procedural and instrument changes makes the detection of biases and adjustment of the data very difficult. In the Chinese temperatures, them are inhomogeneities related to a change in the radiation correction procedure.Test results demonstrate that a modified Easterling and Peterson method is suitable for use in detecting and adjusting time series radiosonde data.Accurate stations histories are very desirable. Stations histories can confirm that detected inhomogeneities are related to instrument or procedural changes. Adjustments can then he made to the data with some confidence.
Ruan, Hang; Li, Jian; Zhang, Lei; Long, Teng
2015-01-01
For vehicle positioning with Global Navigation Satellite System (GNSS) in urban areas, open-loop tracking shows better performance because of its high sensitivity and superior robustness against multipath. However, no previous study has focused on the effects of the code search grid size on the code phase measurement accuracy of open-loop tracking. Traditional open-loop tracking methods are performed by the batch correlators with fixed correlation space. The code search grid size, which is the correlation space, is a constant empirical value and the code phase measuring accuracy will be largely degraded due to the improper grid size, especially when the signal carrier-to-noise density ratio (C/N0) varies. In this study, the Adaptive Correlation Space Adjusted Open-Loop Tracking Approach (ACSA-OLTA) is proposed to improve the code phase measurement dependent pseudo range accuracy. In ACSA-OLTA, the correlation space is adjusted according to the signal C/N0. The novel Equivalent Weighted Pseudo Range Error (EWPRE) is raised to obtain the optimal code search grid sizes for different C/N0. The code phase measuring errors of different measurement calculation methods are analyzed for the first time. The measurement calculation strategy of ACSA-OLTA is derived from the analysis to further improve the accuracy but reduce the correlator consumption. Performance simulation and real tests confirm that the pseudo range and positioning accuracy of ASCA-OLTA are better than the traditional open-loop tracking methods in the usual scenarios of urban area. PMID:26343683
Hohmann, Erik; Glatt, Vaida; Tetsworth, Kevin
2017-06-18
To perform a bibliometric analysis of publications rates in orthopedics in the top 15 orthopaedic journals. Based on their 2015 impact factor, the fifteen highest ranked orthopaedic journals between January 2010 and December 2014 were used to establish the total number of publications; cumulative impact factor points (IF) per country were determined, and normalized to population size, GDP, and GDP/capita, comparison to the median country output and the global leader. Twenty-three thousand and twenty-one orthopaedic articles were published, with 66 countries publishing. The United States had 8149 publications, followed by the United Kingdom (1644) and Japan (1467). The highest IF was achieved by the United States (24744), United Kingdom (4776), and Japan (4053). Normalized by population size Switzerland lead. Normalized by GDP, Croatia was the top achiever. Adjusting GDP/capita, for publications and IF, China, India, and the United States were the leaders. Adjusting for population size and GDP, 28 countries achieved numbers of publications to be considered at least equivalent with the median academic output. Adjusting GDP/capita only China and India reached the number of publications to be considered equivalent to the current global leader, the United States. Five countries were responsible for 60% of the orthopaedic research output over this 5-year period. After correcting for GDP/capita, only 28 of 66 countries achieved a publication rate equivalent to the median country. The United States, United Kingdom, South Korea, Japan, and Germany were the top five countries for both publication totals and cumulative impact factor points.
Association of Modality with Mortality among Canadian Aboriginals
Hemmelgarn, Brenda; Rigatto, Claudio; Komenda, Paul; Yeates, Karen; Promislow, Steven; Mojica, Julie; Tangri, Navdeep
2012-01-01
Summary Background and objectives Previous studies have shown that Aboriginals and Caucasians experience similar outcome on dialysis in Canada. Using the Canadian Organ Replacement Registry, this study examined whether dialysis modality (peritoneal or hemodialysis) impacted mortality in Aboriginal patients. Design, setting, participants, & measurements This study identified 31,576 adult patients (hemodialysis: Aboriginal=1839, Caucasian=21,430; peritoneal dialysis: Aboriginal=554, Caucasian=6769) who initiated dialysis between January of 2000 and December of 2009. Aboriginal status was identified by self-report. Dialysis modality was determined 90 days after dialysis initiation. Multivariate Cox proportional hazards and competing risk models were constructed to determine the association between race and mortality by dialysis modality. Results During the study period, 939 (51.1%) Aboriginals and 12,798 (53.3%) Caucasians initiating hemodialysis died, whereas 166 (30.0%) and 2037 (30.1%), respectively, initiating peritoneal dialysis died. Compared with Caucasians, Aboriginals on hemodialysis had a comparable risk of mortality (adjusted hazards ratio=1.04, 95% confidence interval=0.96–1.11, P=0.37). However, on peritoneal dialysis, Aboriginals experienced a higher risk of mortality (adjusted hazards ratio=1.36, 95% confidence interval=1.13–1.62, P=0.001) and technique failure (adjusted hazards ratio=1.29, 95% confidence interval=1.03–1.60, P=0.03) than Caucasians. The risk of technique failure varied by patient age, with younger Aboriginals (<50 years old) more likely to develop technique failure than Caucasians (adjusted hazards ratio=1.76, 95% confidence interval=1.23–2.52, P=0.002). Conclusions Aboriginals on peritoneal dialysis experience higher mortality and technique failure relative to Caucasians. Reasons for this race disparity in peritoneal dialysis outcomes are unclear. PMID:22997343
radon daughters is associated have greater ability to penetrate the variousfilter media than has the fission product debris in the atmosphere; therefore the former is associated with aerosols of smaller size. A preliminary evaluation of the techniques of employing packs of filters of different retentivity characteristics to determine the particle size and/or particle size distribution of radioactive aerosols has been made which indicates the feasibility of the method. It is recommended that a series of measurements be undertaken to determine the relative particle size
Dittami, Gregory M; Sethi, Manju; Rabbitt, Richard D; Ayliffe, H Edward
2012-06-21
Particle and cell counting is used for a variety of applications including routine cell culture, hematological analysis, and industrial controls(1-5). A critical breakthrough in cell/particle counting technologies was the development of the Coulter technique by Wallace Coulter over 50 years ago. The technique involves the application of an electric field across a micron-sized aperture and hydrodynamically focusing single particles through the aperture. The resulting occlusion of the aperture by the particles yields a measurable change in electric impedance that can be directly and precisely correlated to cell size/volume. The recognition of the approach as the benchmark in cell/particle counting stems from the extraordinary precision and accuracy of its particle sizing and counts, particularly as compared to manual and imaging based technologies (accuracies on the order of 98% for Coulter counters versus 75-80% for manual and vision-based systems). This can be attributed to the fact that, unlike imaging-based approaches to cell counting, the Coulter Technique makes a true three-dimensional (3-D) measurement of cells/particles which dramatically reduces count interference from debris and clustering by calculating precise volumetric information about the cells/particles. Overall this provides a means for enumerating and sizing cells in a more accurate, less tedious, less time-consuming, and less subjective means than other counting techniques(6). Despite the prominence of the Coulter technique in cell counting, its widespread use in routine biological studies has been prohibitive due to the cost and size of traditional instruments. Although a less expensive Coulter-based instrument has been produced, it has limitations as compared to its more expensive counterparts in the correction for "coincidence events" in which two or more cells pass through the aperture and are measured simultaneously. Another limitation with existing Coulter technologies is the lack of metrics on the overall health of cell samples. Consequently, additional techniques must often be used in conjunction with Coulter counting to assess cell viability. This extends experimental setup time and cost since the traditional methods of viability assessment require cell staining and/or use of expensive and cumbersome equipment such as a flow cytometer. The Moxi Z mini automated cell counter, described here, is an ultra-small benchtop instrument that combines the accuracy of the Coulter Principle with a thin-film sensor technology to enable precise sizing and counting of particles ranging from 3-25 microns, depending on the cell counting cassette used. The M type cassette can be used to count particles from with average diameters of 4 - 25 microns (dynamic range 2 - 34 microns), and the Type S cassette can be used to count particles with and average diameter of 3 - 20 microns (dynamic range 2 - 26 microns). Since the system uses a volumetric measurement method, the 4-25 microns corresponds to a cell volume range of 34 - 8,180 fL and the 3 - 20 microns corresponds to a cell volume range of 14 - 4200 fL, which is relevant when non-spherical particles are being measured. To perform mammalian cell counts using the Moxi Z, the cells to be counted are first diluted with ORFLO or similar diluent. A cell counting cassette is inserted into the instrument, and the sample is loaded into the port of the cassette. Thousands of cells are pulled, single-file through a "Cell Sensing Zone" (CSZ) in the thin-film membrane over 8-15 seconds. Following the run, the instrument uses proprietary curve-fitting in conjunction with a proprietary software algorithm to provide coincidence event correction along with an assessment of overall culture health by determining the ratio of the number of cells in the population of interest to the total number of particles. The total particle counts include shrunken and broken down dead cells, as well as other debris and contaminants. The results are presented in histogram format with an automatic curve fit, with gates that can be adjusted manually as needed. Ultimately, the Moxi Z enables counting with a precision and accuracy comparable to a Coulter Z2, the current gold standard, while providing additional culture health information. Furthermore it achieves these results in less time, with a smaller footprint, with significantly easier operation and maintenance, and at a fraction of the cost of comparable technologies.
Multi-Pulse Extraction from Los Alamos Proton Storage Ring for Radiographic Applications
NASA Astrophysics Data System (ADS)
Thiessen, Henry A.; Neri, Filippo; Rust, Kenneth R.; Redd, Dale B.
1997-05-01
For radiography of moving objects, two or more pulses with adjustable time spacing are required. The existing Proton Stotage Ring (PSR) extraction system is configured to extract the entire beam in a single turn. Two kickers and two kicker modulators fired at the same time perform the normal extraction function. By reconfiguring the two kickers and two modulators, it is possible to obtain two half-sized extraction kicks with adjustable time spacing. In this way, we have extracted two pulses with adjustable relative timing. The setup will be described and experimental results will be presented.
1993-03-01
statistical mathe- matics, began in the late 1800’s when Sir Francis Galton first attempted to use practical mathematical techniques to investigate the...randomly collected (sampled) many pairs of parent/child height mea- surements (data), Galton observed that for a given parent- height average, the...ty only Maximum Adjusted R2 will be discussed. However, Maximum Adjusted R’ and Minimum MSE test exactly the same 2.thing. Adjusted R is related to R
Novel expansion techniques for skin grafts
Kadam, Dinesh
2016-01-01
The quest for skin expansion is not restricted to cover a large area alone, but to produce acceptable uniform surfaces, robust engraftment to withstand mechanical shear and infection, with a minimal donor morbidity. Ease of the technique, shorter healing period and reproducible results are essential parameters to adopt novel techniques. Significant advances seen in four fronts of autologous grafting are: (1) Dermal–epidermal graft expansion techniques, (2) epidermal graft harvests technique, (3) melanocyte-rich basal cell therapy for vitiligo and (4) robust and faster autologous cell cultures. Meek's original concept that the sum of perimeter of smaller grafts is larger than the harvested graft, and smaller the graft size, the greater is the potential for regeneration is witnessed in newer modification. Further, as graft size becomes smaller or minced, these micrografts can survive on the wound bed exudate irrespective of their dermal orientation. Expansion produced by 4 mm × 4 mm sized Meek micrografts is 10-folds, similarly 0.8 mm × 0.8 mm size micrografts produce 100-fold expansion, which becomes 700-fold with pixel grafts of 0.3 mm × 0.3 mm size. Fractional skin harvest is another new technique with 700 μ size full thickness graft. These provide instant autologous non-cultured graft to cover extensive areas with similar quality of engraftment surface as split skin grafts. Newer tools for epidermal blister graft harvest quickly, with uniform size to produce 7-fold expansions with reproducible results. In addition, donor area heals faster with minimal scar. Melanocyte-rich cell suspension is utilised in vitiligo surgery tapping the potential of hair root melanocytes. Further advances in the cell culture to reduce the cultivation time and provide stronger epidermal sheets with dermal carrier are seen in trials. PMID:27274117
Yen, Yu-Chun; Chang, Jer-Hwa; Lin, Wei-Cheng; Chiou, Jeng-Fong; Chang, Yin-Chun; Chang, Chia-Lun; Hsu, Han-Lin; Chow, Jyh-Ming; Yuan, Kevin Sheng-Po; Wu, Alexander T H; Wu, Szu-Yuan
2017-06-01
Few large, prospective, randomized studies have investigated the effectiveness of esophagectomy in patients with thoracic esophageal squamous cell carcinoma (TESCC) who receive definitive radiotherapy (RT) or concurrent chemoradiotherapy (CCRT) through modern, intensity modulated-RT (IMRT) techniques. The therapeutic effects of esophagectomy in patients with TESCC were evaluated using modern clinical staging and RT techniques and suitable RT doses. The authors analyzed data from patients with TESCC from the Taiwan Cancer Registry database. Patients were categorized into the following groups on the basis of treatment modality to compare their outcomes: group 1 received definitive CCRT, group 2 received neoadjuvant RT followed by esophagectomy (total IMRT dose, ≥50 grays [Gy]), and group 3 receiving neoadjuvant CCRT followed by esophagectomy (total IMRT dose, ≥ 50 Gy). The median total RT dose and fraction size were 50.4 Gy and 1.8 Gy per fraction, respectively. Group 1 was used as the control arm for investigating the risk of mortality after treatment. In total, 3123 patients who had TESCC without distant metastasis were enrolled. Patient ages 65 years and older, Charlson comorbidity index scores ≥3, advanced clinical stages (IIA-IIIC), alcohol consumption, and cigarette smoking were identified as significant, independent poor prognostic risk factors for overall survival in multivariate Cox regression analyses. In group 3, after adjustment for confounders, the adjusted hazard ratios (95% confidence intervals [CIs]) for overall mortality were 0.62 (95% CI, 0.41-0.93) for patients with clinical stage IIA disease, 0.61 (95% CI, 0.41-0.91) for those with clinical stage IIB disease, 0.47 (95% CI, 0.38-0.55) for those with clinical stage IIIA disease, 0.47 (95% CI, 0.39-0.56) for those with clinical stage IIIB disease, and 0.46 (95% CI, 0.37-0.57) for those with clinical stage IIIC disease. Esophagectomy can be beneficial in patients with TESCC after definitive CCRT, especially in those who have advanced-stage disease. Cancer 2017;123:2043-2053. © 2017 American Cancer Society. © 2017 American Cancer Society.
Iniesta-Sepúlveda, Marina; Rosa-Alcázar, Ana I; Sánchez-Meca, Julio; Parada-Navas, José L; Rosa-Alcázar, Ángel
2017-06-01
A meta-analysis on the efficacy of cognitive-behavior-family treatment (CBFT) on children and adolescents with obsessive-compulsive disorder (OCD) was accomplished. The purposes of the study were: (a) to estimate the effect magnitude of CBFT in ameliorating obsessive-compulsive symptoms and reducing family accommodation on pediatric OCD and (b) to identify potential moderator variables of the effect sizes. A literature search enabled us to identify 27 studies that fulfilled our selection criteria. The effect size index was the standardized pretest-postest mean change index. For obsessive-compulsive symptoms, the adjusted mean effect size for CBFT was clinically relevant and statistically significant in the posttest (d adj =1.464). For family accommodation the adjusted mean effect size was also positive and statistically significant, but in a lesser extent than for obsessive-compulsive symptoms (d adj =0.511). Publication bias was discarded as a threat against the validity of the meta-analytic results. Large heterogeneity among effect sizes was found. Better results were found when CBFT was individually applied than in group (d + =2.429 and 1.409, respectively). CBFT is effective to reduce obsessive-compulsive symptoms, but offers a limited effect for family accommodation. Additional modules must be included in CBFT to improve its effectiveness on family accommodation. Copyright © 2017 Elsevier Ltd. All rights reserved.
Seasonally different reproductive investment in a medium-sized rodent (Cavia aperea).
Rübensam, K; Hribal, R; Jewgenow, K; Guenther, A
2015-09-01
Pronounced seasonal variations in day length, temperature, and resource availability characterize the temperate regions and strongly influence the animals living in these environments. To survive and reproduce successfully, animals must allocate resources among competing physiological systems, and they usually adjust their time of breeding to the most adequate season. Here, we examined whether reproductive investment in the wild guinea pig (Cavia aperea) differs across seasons. We kept animals in combined indoor-outdoor enclosures under natural light and temperature year-round. We measured littering probability, litter size, and birth weight, as well as maternal weight loss during lactation. In addition, we measured ovulation rate as a parameter to adjust reproductive investment prenatally. Our data reveal strong seasonal variations in reproductive traits despite the fact that the animals reproduced year-round. The results show a reduced reproductive investment in winter, indicated by a lower litter size and birth weight of pups, whereas investment was highest in warm seasons (summer and autumn) with higher litter size and birth weight. Maternal weight loss in lactation was highest in cold seasons even if the litter size was lower. Furthermore, we found the regulation on the proximate level of the reproductive investment, the ovulation rate, to differ significantly between the seasons. Copyright © 2015 Elsevier Inc. All rights reserved.
Exact special twist method for quantum Monte Carlo simulations
NASA Astrophysics Data System (ADS)
Dagrada, Mario; Karakuzu, Seher; Vildosola, Verónica Laura; Casula, Michele; Sorella, Sandro
2016-12-01
We present a systematic investigation of the special twist method introduced by Rajagopal et al. [Phys. Rev. B 51, 10591 (1995), 10.1103/PhysRevB.51.10591] for reducing finite-size effects in correlated calculations of periodic extended systems with Coulomb interactions and Fermi statistics. We propose a procedure for finding special twist values which, at variance with previous applications of this method, reproduce the energy of the mean-field infinite-size limit solution within an adjustable (arbitrarily small) numerical error. This choice of the special twist is shown to be the most accurate single-twist solution for curing one-body finite-size effects in correlated calculations. For these reasons we dubbed our procedure "exact special twist" (EST). EST only needs a fully converged independent-particles or mean-field calculation within the primitive cell and a simple fit to find the special twist along a specific direction in the Brillouin zone. We first assess the performances of EST in a simple correlated model such as the three-dimensional electron gas. Afterwards, we test its efficiency within ab initio quantum Monte Carlo simulations of metallic elements of increasing complexity. We show that EST displays an overall good performance in reducing finite-size errors comparable to the widely used twist average technique but at a much lower computational cost since it involves the evaluation of just one wave function. We also demonstrate that the EST method shows similar performances in the calculation of correlation functions, such as the ionic forces for structural relaxation and the pair radial distribution function in liquid hydrogen. Our conclusions point to the usefulness of EST for correlated supercell calculations; our method will be particularly relevant when the physical problem under consideration requires large periodic cells.
Further evaluation of traditional icing scaling methods
NASA Technical Reports Server (NTRS)
Anderson, David N.
1996-01-01
This report provides additional evaluations of two methods to scale icing test conditions; it also describes a hybrid technique for use when scaled conditions are outside the operating envelope of the test facility. The first evaluation is of the Olsen method which can be used to scale the liquid-water content in icing tests, and the second is the AEDC (Ruff) method which is used when the test model is less than full size. Equations for both scaling methods are presented in the paper, and the methods were evaluated by performing icing tests in the NASA Lewis Icing Research Tunnel (IRT). The Olsen method was tested using 53 cm diameter NACA 0012 airfoils. Tests covered liquid-water-contents which varied by as much as a factor of 1.8. The Olsen method was generally effective in giving scale ice shapes which matched the reference shapes for these tests. The AEDC method was tested with NACA 0012 airfoils with chords from 18 cm to 53 cm. The 53 cm chord airfoils were used in reference tests, and 1/2 and 1/3 scale tests were made at conditions determined by applying the AEDC scaling method. The scale and reference airspeeds were matched in these tests. The AEDC method was found to provide fairly effective scaling for 1/2 size tests, but for 1/3 size models, scaling was generally less effective. In addition to these two scaling methods, a hybrid approach was also tested in which the Olsen method was used to adjust the LWC after size was scaled using the constant Weber number method. This approach was found to be an effective way to test when scaled conditions would otherwise be outside the capability of the test facility.
Rosenberger, Amanda E.; Dunham, Jason B.
2005-01-01
Estimation of fish abundance in streams using the removal model or the Lincoln - Peterson mark - recapture model is a common practice in fisheries. These models produce misleading results if their assumptions are violated. We evaluated the assumptions of these two models via electrofishing of rainbow trout Oncorhynchus mykiss in central Idaho streams. For one-, two-, three-, and four-pass sampling effort in closed sites, we evaluated the influences of fish size and habitat characteristics on sampling efficiency and the accuracy of removal abundance estimates. We also examined the use of models to generate unbiased estimates of fish abundance through adjustment of total catch or biased removal estimates. Our results suggested that the assumptions of the mark - recapture model were satisfied and that abundance estimates based on this approach were unbiased. In contrast, the removal model assumptions were not met. Decreasing sampling efficiencies over removal passes resulted in underestimated population sizes and overestimates of sampling efficiency. This bias decreased, but was not eliminated, with increased sampling effort. Biased removal estimates based on different levels of effort were highly correlated with each other but were less correlated with unbiased mark - recapture estimates. Stream size decreased sampling efficiency, and stream size and instream wood increased the negative bias of removal estimates. We found that reliable estimates of population abundance could be obtained from models of sampling efficiency for different levels of effort. Validation of abundance estimates requires extra attention to routine sampling considerations but can help fisheries biologists avoid pitfalls associated with biased data and facilitate standardized comparisons among studies that employ different sampling methods.
NASA Technical Reports Server (NTRS)
Santavicca, Dom A.; Coy, E.
1990-01-01
Droplet turbulence interactions directly affect the vaporization and dispersion of droplets in liquid sprays and therefore play a major role in fuel oxidizer mixing in liquid fueled combustion systems. Proper characterization of droplet turbulence interactions in vaporizing sprays require measurement of droplet size velocity and size temperature correlations. A planar, fluorescence imaging technique is described which is being developed for simultaneously measuring the size, velocity, and temperature of individual droplets in vaporizing sprays. Preliminary droplet size velocity correlation measurements made with this technique are presented. These measurements are also compared to and show very good agreement with measurements made in the same spray using a phase Doppler particle analyzer.
Apparatus for and method of correcting for aberrations in a light beam
Sawicki, Richard H.
1996-01-01
A technique for adjustably correcting for aberrations in a light beam is disclosed herein. This technique utilizes first means which defines a flat, circular light reflecting surface having opposite reinforced circumferential edges and a central post and which is resiliently distortable, to a limited extent, into different concave and/or convex curvatures, which may be Gaussian-like, about the central axis, and second means acting on the first means for adjustably distorting the light reflecting surface into a particular selected one of the different curvatures depending upon the aberrations to be corrected for and for fixedly maintaining the curvature selected. In the embodiment disclosed, the light reflecting surface is adjustably distorted into the selected curvature by application of particular axial moments to the central post on the opposite side from the light reflecting surface and lateral moments to the circumference of the reflecting surface.
Apparatus for and method of correcting for aberrations in a light beam
Sawicki, R.H.
1996-09-17
A technique for adjustably correcting for aberrations in a light beam is disclosed herein. This technique utilizes first means which defines a flat, circular light reflecting surface having opposite reinforced circumferential edges and a central post and which is resiliently distortable, to a limited extent, into different concave and/or convex curvatures, which may be Gaussian-like, about the central axis, and second means acting on the first means for adjustably distorting the light reflecting surface into a particular selected one of the different curvatures depending upon the aberrations to be corrected for and for fixedly maintaining the curvature selected. In the embodiment disclosed, the light reflecting surface is adjustably distorted into the selected curvature by application of particular axial moments to the central post on the opposite side from the light reflecting surface and lateral moments to the circumference of the reflecting surface. 8 figs.
Kraaij, Vivian; Garnefski, Nadia
2015-03-01
The aim of the present study was to find relevant coping factors for the development of psychological intervention programs for young people with Type 1 (T1) diabetes. A wide range of coping techniques was studied, including cognitive coping, behavioral coping and goal adjustment coping. A total of 78 young people with T1 diabetes participated. They were contacted through a social networking website, several Internet sites, and flyers. A wide range of coping techniques appeared to be related to depressive symptoms. Especially the cognitive coping strategies self-blame, rumination, refocus positive, and other-blame, together with goal adjustment coping, were of importance. A large proportion of the variance of depressive symptoms could be explained (65 %). These findings suggest that these specific coping strategies should be part of coping skills trainings for young people with T1 diabetes.
Buchinger, Tyler J.; Bussy, Ugo; Buchinger, Ethan G.; Fissette, Skye D.; Li, Weiming; Johnson, Nicholas
2017-01-01
Male body size affects access to mates in many animals. Attributes of sexual signals often correlate with body size due to physiological constraints on signal production. Larger males generally produce larger signals, but costs of being large or compensation by small males can result in smaller males producing signals of equal or greater magnitude. Female choice following multiple male traits with different relationships to size might further complicate the effect of male body size on access to mates. We report the relationship between male body size and pheromone signaling, and the effects on female mate search and courtship in the sea lamprey (Petromyzon marinus). We predicted that pheromone production in the liver and the liver mass to body mass ratio would remain constant across sizes, resulting in similar mass-adjusted pheromone release rates across sizes but a positive relationship between absolute pheromone release and body mass. Our results confirmed positive relationships between body mass and liver mass, and liver mass and the magnitude of the pheromone signal. Surprisingly, decreasing body mass was correlated with higher pheromone concentrations in the liver, liver mass to body mass ratios, and mass-adjusted pheromone release rates. In a natural stream, females more often entered nests treated with small versus large male odors. However, close-proximity courtship behaviors were similar in nests treated with small or large male odors. We conclude that small males exhibit increased release of the main pheromone component, but female discrimination of male pheromones follows several axes of variation with different relationships to size.
Wei, Wei; Chang, Jun; Wang, Qiang; Qin, Zengguang
2017-01-15
A new technique of modulation index adjustment for pure wavelength modulation spectroscopy second harmonic signal waveforms recovery is presented. As the modulation index is a key parameter in determining the exact form of the signals generated by the technique of wavelength modulation spectroscopy, the method of modulation index adjustment is applied to recover the second harmonic signal with wavelength modulation spectroscopy. By comparing the measured profile with the theoretical profile by calculation, the relationship between the modulation index and average quantities of the scanning wavelength can be obtained. Furthermore, when the relationship is applied in the experimental setup by point-by-point modulation index modification for gas detection, the results show good agreement with the theoretical profile and signal waveform distortion (such as the amplitude modulation effect caused by diode laser) can be suppressed. Besides, the method of modulation index adjustment can be used in many other aspects which involve profile improvement. In practical applications, when the amplitude modulation effect can be neglected and the stability of the detection system is limited by the sampling rate of analog-to-digital, modulation index adjustment can be used to improve detection into softer inflection points and solve the insufficient sampling problem. As a result, measurement stability is improved by 40%.
Wei, Wei; Chang, Jun; Wang, Qiang; Qin, Zengguang
2017-01-01
A new technique of modulation index adjustment for pure wavelength modulation spectroscopy second harmonic signal waveforms recovery is presented. As the modulation index is a key parameter in determining the exact form of the signals generated by the technique of wavelength modulation spectroscopy, the method of modulation index adjustment is applied to recover the second harmonic signal with wavelength modulation spectroscopy. By comparing the measured profile with the theoretical profile by calculation, the relationship between the modulation index and average quantities of the scanning wavelength can be obtained. Furthermore, when the relationship is applied in the experimental setup by point-by-point modulation index modification for gas detection, the results show good agreement with the theoretical profile and signal waveform distortion (such as the amplitude modulation effect caused by diode laser) can be suppressed. Besides, the method of modulation index adjustment can be used in many other aspects which involve profile improvement. In practical applications, when the amplitude modulation effect can be neglected and the stability of the detection system is limited by the sampling rate of analog-to-digital, modulation index adjustment can be used to improve detection into softer inflection points and solve the insufficient sampling problem. As a result, measurement stability is improved by 40%. PMID:28098842
An Energy-Aware Runtime Management of Multi-Core Sensory Swarms.
Kim, Sungchan; Yang, Hoeseok
2017-08-24
In sensory swarms, minimizing energy consumption under performance constraint is one of the key objectives. One possible approach to this problem is to monitor application workload that is subject to change at runtime, and to adjust system configuration adaptively to satisfy the performance goal. As today's sensory swarms are usually implemented using multi-core processors with adjustable clock frequency, we propose to monitor the CPU workload periodically and adjust the task-to-core allocation or clock frequency in an energy-efficient way in response to the workload variations. In doing so, we present an online heuristic that determines the most energy-efficient adjustment that satisfies the performance requirement. The proposed method is based on a simple yet effective energy model that is built upon performance prediction using IPC (instructions per cycle) measured online and power equation derived empirically. The use of IPC accounts for memory intensities of a given workload, enabling the accurate prediction of execution time. Hence, the model allows us to rapidly and accurately estimate the effect of the two control knobs, clock frequency adjustment and core allocation. The experiments show that the proposed technique delivers considerable energy saving of up to 45%compared to the state-of-the-art multi-core energy management technique.
An Energy-Aware Runtime Management of Multi-Core Sensory Swarms
Kim, Sungchan
2017-01-01
In sensory swarms, minimizing energy consumption under performance constraint is one of the key objectives. One possible approach to this problem is to monitor application workload that is subject to change at runtime, and to adjust system configuration adaptively to satisfy the performance goal. As today’s sensory swarms are usually implemented using multi-core processors with adjustable clock frequency, we propose to monitor the CPU workload periodically and adjust the task-to-core allocation or clock frequency in an energy-efficient way in response to the workload variations. In doing so, we present an online heuristic that determines the most energy-efficient adjustment that satisfies the performance requirement. The proposed method is based on a simple yet effective energy model that is built upon performance prediction using IPC (instructions per cycle) measured online and power equation derived empirically. The use of IPC accounts for memory intensities of a given workload, enabling the accurate prediction of execution time. Hence, the model allows us to rapidly and accurately estimate the effect of the two control knobs, clock frequency adjustment and core allocation. The experiments show that the proposed technique delivers considerable energy saving of up to 45%compared to the state-of-the-art multi-core energy management technique. PMID:28837094
NASA Astrophysics Data System (ADS)
Grutter, A. S.; Blomberg, S. P.; Fargher, B.; Kuris, A. M.; McCormick, M. I.; Warner, R. R.
2017-06-01
The transition between the planktonic and the benthic habitat is a critical period for the larvae of many demersal marine organisms. Understanding the potential constraints on the timing of this habitat transition, called settlement, is important to understanding their biology. Size-specific mortality can set the limits on lifestyle and help explain ontogenetic habitat shifts. We examined whether size-based mortality risks after settlement may include micropredation by ectoparasites by testing whether survival of settlement-stage fish varies with fish size when exposed to a reef-associated micropredator. Fish (14 species) were exposed to one blood-sucking gnathiid isopod overnight, with appropriate controls; gnathiid feeding success and survival, and fish mortality were recorded relative to fish size. After adjusting for fish relatedness, we found the relationship between fish mortality and size differed with gnathiid exposure: for gnathiid-exposed fish, the mean mortality of the smallest fish was much higher (57%) than unexposed controls (10%), and decreased to 0% for fish >12 mm standard length (SL); mortality was almost nil in controls. Thus, a predicted optimal size to switch habitat and reduce mortality risk from micropredation should be >12 mm SL. We then asked what species might be at greater risk and if the steep increase in survival at 12 mm SL might coincide with settlement at larger sizes among fishes. Across 102 other species (32 families), 61% settled at ≥12 mm SL. After adjusting for relatedness, mean fish settlement size was 15.0 mm and this was not significantly different from 12 mm. Thus, settlement size clusters around the minimum fish size threshold our gnathiid experiment predicted would be large enough to survive a gnathiid encounter. These results suggest micropredators may contribute to size-selective mortality during settlement processes and are consistent with the hypothesis that the pelagic phase provides fish an escape from certain micropredators.
Roumanas, Eleni D
2010-03-01
The authors analyzed the dental records of 2780 Navy (cohort 1 = 1078 entered the Navy in 1997) and US Marine Corps recruits (cohort 2 =1053 entered the USMC in 1999-2000; cohort 3 = 649 entered the USMC in 2002-2005). The records were reviewed at 16 US Navy dental treatment facilities at the following time periods: cohort 1, 2001; cohort 2, 2002-2003; and cohort 3, 2005-2006. The mean age of the subjects was 20 years, and 85% were men. Only posterior teeth (not third molars) with amalgam or resin-based composite (including glass ionomer restorations) were evaluated. Teeth that had been restored with more than one material and restorations that did not involve the occlusal surface were excluded. The minimum follow-up time was 2 years with at least 2 periodic exams following the initial exam. The primary factor of interest was the type of restorative material (amalgam versus resin-based composite). Secondary factors included tooth number, number of restored surfaces (single or multiple), and caries risk of the patient. Caries risk status was defined using the Navy Dental Corps Oral Disease Risk Management protocol. The primary outcome measure of interest was the determination of the relative risk of replacement of an initially intact restoration during the subject's first years of military service. Restorations were classified as clinically acceptable or requiring replacement either as a result of new primary caries, secondary caries, defective restorations, or endodontic therapy. At the initial exam, 964 (15.2%) of the amalgam restorations and 199 (17.4%) of the resin-based composites required replacement and were excluded from further analysis. Of the remaining restorations, an additional 14.2% of the amalgam and 16.7% of the composite restorations required replacement during the observation period. The mean follow-up time was 3.0 years (cohort 1, 3.4 years; cohort 2, 3.1 years; cohort 3, 2.3 years). Replacement rates for resin-based composite restorations compared with amalgam were significantly higher owing to all causes (adjusted hazard ratio [HR], 1.28; P < .05) and for replacement owing to restoration failure (adjusted HR, 1.64; P < .01). Multiple surface restorations demonstrated higher rates of replacement than single surface restorations from all causes (adjusted HR, 1.39; P < .01) and for replacement of existing restorations (adjusted HR, 1.82; P < .01). High-caries-risk subjects experienced more than twice the risk of retreatment than did low-caries-risk subjects when considering all replacements (adjusted HR, 2.04; P < .01) and 50% higher risk of replacement of previously restored surfaces (adjusted HR, 1.48; P<.01) Approximately 30% of all posterior restorations required replacement either at the initial or subsequent exams during the observation period. The number of resin-based composite restorations requiring replacement was significantly higher than amalgam restorations. The authors concluded that because of the extra cost, time, and potential for increased frequency of replacement, posterior composite restorations should be limited to restorations of appropriate size and placed under meticulous restorative technique with strict adherence to manufacturer's instructions.
A technique for production of nanocrystalline cellulose with a narrow size distribution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bai, Wen; Holbery, James D.; Li, Kaichang
2009-02-01
Nanocrystalline cellulose (NCC) was prepared by sulfuric acid hydrolysis of microcrystalline cellulose. A differential centrifugation technique was studied to obtain NCC whiskers with a narrow size distribution. It was shown that the volume of NCC in different fractions had an inverse relationship with relative centrifugal force (RCF). The length of NCC whiskers was also fractionized by differential RCF. The aspect ratio of NCC in different fractions had a relatively narrow range. This technique provides an easy way of producing NCC whiskers with a narrow size distribution.
A cost analysis of single-row versus double-row and suture bridge rotator cuff repair methods.
Bisson, Leslie; Zivaljevic, Nikola; Sanders, Samuel; Pula, David
2015-02-01
To calculate the costs to the US healthcare system of transition from single-row (SR) to double-row (DR) rotator cuff repair (RCR) and to calculate the decrease in re-operations for re-tear that DR RCR would need to accomplish in order to render the transition cost-neutral. Standard accounting methods were used to determine the cost of a single RCR, the annual cost to the US healthcare system of rotator cuff surgery, the cost of a single-revision RCR, and the decrease in revision for re-tear rate necessary to make DR or suture bridge (SB) methods cost-neutral in comparison with SR methods. We varied tear size, operating room cost, time required for implant placement, annual tear size distribution, and repair method. The cost of RCR ranged from $7,572 (SR, <1 cm tear) to $12,979 (DR, >5 cm tear). Complete conversion from SR RCR to a DR technique without an associated decrease in revision surgeries would increase the annual US healthcare cost between $80 million and $262 million per year. To obtain cost neutrality, use of DR or SB methods would need to result in one fewer revision in every 17 primary repairs (for tears <1 cm) to one fewer in every four primary repairs (for tears >5 cm). Conversion from SR to DR or SB RCR techniques would result in considerable increases in healthcare expenditures. Since the large decreases in revision surgery rates necessary to justify DR or SB repairs purely on a cost basis may not be realistic or even possible, the use of these methods should be supported by evidence of improved structural healing rates and quality-adjusted life years in comparison with SR methods. IV.
Kazemi, Pezhman; Khalid, Mohammad Hassan; Pérez Gago, Ana; Kleinebudde, Peter; Jachowicz, Renata; Szlęk, Jakub; Mendyk, Aleksander
2017-01-01
Dry granulation using roll compaction is a typical unit operation for producing solid dosage forms in the pharmaceutical industry. Dry granulation is commonly used if the powder mixture is sensitive to heat and moisture and has poor flow properties. The output of roll compaction is compacted ribbons that exhibit different properties based on the adjusted process parameters. These ribbons are then milled into granules and finally compressed into tablets. The properties of the ribbons directly affect the granule size distribution (GSD) and the quality of final products; thus, it is imperative to study the effect of roll compaction process parameters on GSD. The understanding of how the roll compactor process parameters and material properties interact with each other will allow accurate control of the process, leading to the implementation of quality by design practices. Computational intelligence (CI) methods have a great potential for being used within the scope of quality by design approach. The main objective of this study was to show how the computational intelligence techniques can be useful to predict the GSD by using different process conditions of roll compaction and material properties. Different techniques such as multiple linear regression, artificial neural networks, random forest, Cubist and k-nearest neighbors algorithm assisted by sevenfold cross-validation were used to present generalized models for the prediction of GSD based on roll compaction process setting and material properties. The normalized root-mean-squared error and the coefficient of determination (R2) were used for model assessment. The best fit was obtained by Cubist model (normalized root-mean-squared error =3.22%, R2=0.95). Based on the results, it was confirmed that the material properties (true density) followed by compaction force have the most significant effect on GSD. PMID:28176905
Kazemi, Pezhman; Khalid, Mohammad Hassan; Pérez Gago, Ana; Kleinebudde, Peter; Jachowicz, Renata; Szlęk, Jakub; Mendyk, Aleksander
2017-01-01
Dry granulation using roll compaction is a typical unit operation for producing solid dosage forms in the pharmaceutical industry. Dry granulation is commonly used if the powder mixture is sensitive to heat and moisture and has poor flow properties. The output of roll compaction is compacted ribbons that exhibit different properties based on the adjusted process parameters. These ribbons are then milled into granules and finally compressed into tablets. The properties of the ribbons directly affect the granule size distribution (GSD) and the quality of final products; thus, it is imperative to study the effect of roll compaction process parameters on GSD. The understanding of how the roll compactor process parameters and material properties interact with each other will allow accurate control of the process, leading to the implementation of quality by design practices. Computational intelligence (CI) methods have a great potential for being used within the scope of quality by design approach. The main objective of this study was to show how the computational intelligence techniques can be useful to predict the GSD by using different process conditions of roll compaction and material properties. Different techniques such as multiple linear regression, artificial neural networks, random forest, Cubist and k-nearest neighbors algorithm assisted by sevenfold cross-validation were used to present generalized models for the prediction of GSD based on roll compaction process setting and material properties. The normalized root-mean-squared error and the coefficient of determination ( R 2 ) were used for model assessment. The best fit was obtained by Cubist model (normalized root-mean-squared error =3.22%, R 2 =0.95). Based on the results, it was confirmed that the material properties (true density) followed by compaction force have the most significant effect on GSD.
Li, Xiaoyan; Rymer, William Zev; Zhou, Ping
2013-01-01
Motor unit number index (MUNIX) measurement has recently achieved increasing attention as a tool to evaluate the progression of motoneuron diseases. In our current study, the sensitivity of the MUNIX technique to changes in motoneuron and muscle properties was explored by a simulation approach utilizing variations on published motoneuron pool and surface electromyogram (EMG) models. Our simulation results indicate that, when keeping motoneuron pool and muscle parameters unchanged and varying the input motor unit numbers to the model, then MUNIX estimates can appropriately characterize changes in motor unit numbers. Such MUNIX estimates are not sensitive to different motor unit recruitment and rate coding strategies used in the model. Furthermore, alterations in motor unit control properties do not have a significant effect on the MUNIX estimates. Neither adjustment of the motor unit recruitment range nor reduction of the motor unit firing rates jeopardizes the MUNIX estimates. The MUNIX estimates closely correlate with the maximum M wave amplitude. However, if we reduce the amplitude of each motor unit action potential rather than simply reduce motor unit number, then MUNIX estimates substantially underestimate the motor unit numbers in the muscle. These findings suggest that the current MUNIX definition is most suitable for motoneuron diseases that demonstrate secondary evidence of muscle fiber reinnervation. In this regard, when MUNIX is applied, it is of much importance to examine a parallel measurement of motor unit size index (MUSIX), defined as the ratio of the maximum M wave amplitude to the MUNIX. However, there are potential limitations in the application of the MUNIX methods in atrophied muscle, where it is unclear whether the atrophy is accompanied by loss of motor units or loss of muscle fiber size. PMID:22514208
Eskelin, Katri; Lampi, Mirka; Meier, Florian; Moldenhauer, Evelin; Bamford, Dennis H; Oksanen, Hanna M
2017-11-01
Viruses come in various shapes and sizes, and a number of viruses originate from extremities, e.g. high salinity or elevated temperature. One challenge for studying extreme viruses is to find efficient purification conditions where viruses maintain their infectivity. Asymmetrical flow field-flow fractionation (AF4) is a gentle native chromatography-like technique for size-based separation. It does not have solid stationary phase and the mobile phase composition is readily adjustable according to the sample needs. Due to the high separation power of specimens up to 50 µm, AF4 is suitable for virus purification. Here, we applied AF4 for extremophilic viruses representing four morphotypes: lemon-shaped, tailed and tailless icosahedral, as well as pleomorphic enveloped. AF4 was applied to input samples of different purity: crude supernatants of infected cultures, polyethylene glycol-precipitated viruses and viruses purified by ultracentrifugation. All four virus morphotypes were successfully purified by AF4. AF4 purification of culture supernatants or polyethylene glycol-precipitated viruses yielded high recoveries, and the purities were comparable to those obtained by the multistep ultracentrifugation purification methods. In addition, we also demonstrate that AF4 is a rapid monitoring tool for virus production in slowly growing host cells living in extreme conditions.
Modeling precursor diffusion and reaction of atomic layer deposition in porous structures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keuter, Thomas, E-mail: t.keuter@fz-juelich.de; Menzler, Norbert Heribert; Mauer, Georg
2015-01-01
Atomic layer deposition (ALD) is a technique for depositing thin films of materials with a precise thickness control and uniformity using the self-limitation of the underlying reactions. Usually, it is difficult to predict the result of the ALD process for given external parameters, e.g., the precursor exposure time or the size of the precursor molecules. Therefore, a deeper insight into ALD by modeling the process is needed to improve process control and to achieve more economical coatings. In this paper, a detailed, microscopic approach based on the model developed by Yanguas-Gil and Elam is presented and additionally compared with themore » experiment. Precursor diffusion and second-order reaction kinetics are combined to identify the influence of the porous substrate's microstructural parameters and the influence of precursor properties on the coating. The thickness of the deposited film is calculated for different depths inside the porous structure in relation to the precursor exposure time, the precursor vapor pressure, and other parameters. Good agreement with experimental results was obtained for ALD zirconiumdioxide (ZrO{sub 2}) films using the precursors tetrakis(ethylmethylamido)zirconium and O{sub 2}. The derivation can be adjusted to describe other features of ALD processes, e.g., precursor and reactive site losses, different growth modes, pore size reduction, and surface diffusion.« less
Smollon, William E; Wooten, Billy R; Hammond, Billy R
2015-11-01
Heterochromatic flicker photometry (HFP) is the most common technique of measuring macular pigment optical density (MPOD). Some data strongly suggest that HFP samples MPOD specifically at the edge of center-fixated circular stimuli. Other data have led to the conclusion that HFP samples over the entire area of the stimulus. To resolve this disparity, MPOD was measured using HFP and a series of solid discs of varying radii (0.25 to 2.0 deg) and with thin annuli corresponding to the edge of those discs. MPOD assessed with the two methods yielded excellent correspondence and linearity: Y=0.01+0.98X , r=0.96. A second set of experiments showed that if a disc stimulus is adjusted for no-flicker (the standard procedure) and simply reduced in size, no flicker is observed despite the higher level of MPOD in the smaller area. Taken together, these results confirm that MPOD is determined at the edge of the measuring stimulus when using stimulus sizes in the range that is in dispute (up to a radius of 0.75 deg). The basis for this edge effect can be explained by quantitative differences in the spatial-temporal properties of the visual field as a function of angular distance from the fixation point.
Rodrigues, Wellington Francisco; Miguel, Camila Botelho; Napimoga, Marcelo Henrique; Oliveira, Carlo Jose Freire; Lazo-Chica, Javier Emilio
2014-01-01
Strategies for obtaining reliable results are increasingly implemented in order to reduce errors in the analysis of human and veterinary samples; however, further data are required for murine samples. Here, we determined an average factor from the murine body surface area for the calculation of biochemical renal parameters, assessed the effects of storage and freeze-thawing of C57BL/6 mouse samples on plasmatic and urinary urea, and evaluated the effects of using two different urea-measurement techniques. After obtaining 24 h urine samples, blood was collected, and body weight and length were established. The samples were evaluated after collection or stored at -20°C and -70°C. At different time points (0, 4, and 90 days), these samples were thawed, the creatinine and/or urea concentrations were analyzed, and samples were restored at these temperatures for further measurements. We show that creatinine clearance measurements should be adjusted according to the body surface area, which was calculated based on the weight and length of the animal. Repeated freeze-thawing cycles negatively affected the urea concentration; the urea concentration was more reproducible when using the modified Berthelot reaction rather than the ultraviolet method. Our findings will facilitate standardization and optimization of methodology as well as understanding of renal and other biochemical data obtained from mice.
Tahriri, Farzad; Dawal, Siti Zawiah Md; Taha, Zahari
2014-01-01
A new multiobjective dynamic fuzzy genetic algorithm is applied to solve a fuzzy mixed-model assembly line sequencing problem in which the primary goals are to minimize the total make-span and minimize the setup number simultaneously. Trapezoidal fuzzy numbers are implemented for variables such as operation and travelling time in order to generate results with higher accuracy and representative of real-case data. An improved genetic algorithm called fuzzy adaptive genetic algorithm (FAGA) is proposed in order to solve this optimization model. In establishing the FAGA, five dynamic fuzzy parameter controllers are devised in which fuzzy expert experience controller (FEEC) is integrated with automatic learning dynamic fuzzy controller (ALDFC) technique. The enhanced algorithm dynamically adjusts the population size, number of generations, tournament candidate, crossover rate, and mutation rate compared with using fixed control parameters. The main idea is to improve the performance and effectiveness of existing GAs by dynamic adjustment and control of the five parameters. Verification and validation of the dynamic fuzzy GA are carried out by developing test-beds and testing using a multiobjective fuzzy mixed production assembly line sequencing optimization problem. The simulation results highlight that the performance and efficacy of the proposed novel optimization algorithm are more efficient than the performance of the standard genetic algorithm in mixed assembly line sequencing model. PMID:24982962
NASA Technical Reports Server (NTRS)
Lubecke, Victor M.; Mcgrath, William R.; Rutledge, David B.
1991-01-01
Planar RF circuits are used in a wide range of applications from 1 GHz to 300 GHz, including radar, communications, commercial RF test instruments, and remote sensing radiometers. These circuits, however, provide only fixed tuning elements. This lack of adjustability puts severe demands on circuit design procedures and materials parameters. We have developed a novel tuning element which can be incorporated into the design of a planar circuit in order to allow active, post-fabrication tuning by varying the electrical length of a coplanar strip transmission line. It consists of a series of thin plates which can slide in unison along the transmission line, and the size and spacing of the plates are designed to provide a large reflection of RF power over a useful frequency bandwidth. Tests of this structure at 1 GHz to 3 Ghz showed that it produced a reflection coefficient greater than 0.90 over a 20 percent bandwidth. A 2 GHz circuit incorporating this tuning element was also tested to demonstrate practical tuning ranges. This structure can be fabricated for frequencies as high as 1000 GHz using existing micromachining techniques. Many commercial applications can benefit from this micromechanical RF tuning element, as it will aid in extending microwave integrated circuit technology into the high millimeter wave and submillimeter wave bands by easing constraints on circuit technology.
Transforce lingual appliances pre-adjusted invisible appliances simplify treatment.
Clark, William John
2011-01-01
Transforce lingual appliances are designed to be used in conjunction with conventional fixed appliances. Lingual arch development is normally followed by bonded fixed appliances to detail the occlusion. Alternatively Transforce appliance treatment is an efficient method of preparing complex malocclusions prior to a finishing stage with invisible appliances. This approach is ideal for adult treatment, using light continuous forces for arch development with appliances that are comfortable to wear. Sagittal and Transverse appliances are designed for arch development in a range of sizes for contracted arches. They can be used to treat all classes of malocclusion and are pre-adjusted fixed/removable devices for non-compliance treatment. Force modules with nickel titanium coil springs enclosed in a tube deliver a gentle, biocompatible continuous force with a long range of action. They are excellent for mixed dentition and ideal for adult arch development. There are multiple sizes for upper and lower arch development and a sizing chart may be placed over a study model for correct selection, eliminating the need for laboratory work.
NASA Astrophysics Data System (ADS)
Purnamasari, L.; Iskandar, H. H. B.; Makes, B. N.
2017-08-01
In digitized radiography techniques, adjusting the image enhancement can improve the subjective image quality by optimizing the brightness and contrast for diagnostic needs. To determine the value range of image enhancement (brightness and contrast) on chronic apical abscess and apical granuloma interpretation. 30 periapical radiographs that diagnosed chronic apical abscess and 30 that diagnosed apical granuloma were adjusted by changing brightness and contrast values. The value range of brightness and contrast adjustment that can be tolerated in radiographic interpretations of chronic apical abscess and apical granuloma spans from -10 to +10. Brightness and contrast adjustments on digital radiographs do not affect the radiographic interpretation of chronic apical abscess and apical granuloma if conducted within the value range.
NASA Astrophysics Data System (ADS)
Motzkus, C.; Macé, T.; Gaie-Levrel, F.; Ducourtieux, S.; Delvallee, A.; Dirscherl, K.; Hodoroaba, V.-D.; Popov, I.; Popov, O.; Kuselman, I.; Takahata, K.; Ehara, K.; Ausset, P.; Maillé, M.; Michielsen, N.; Bondiguel, S.; Gensdarmes, F.; Morawska, L.; Johnson, G. R.; Faghihi, E. M.; Kim, C. S.; Kim, Y. H.; Chu, M. C.; Guardado, J. A.; Salas, A.; Capannelli, G.; Costa, C.; Bostrom, T.; Jämting, Å. K.; Lawn, M. A.; Adlem, L.; Vaslin-Reimann, S.
2013-10-01
Results of an interlaboratory comparison on size characterization of SiO2 airborne nanoparticles using on-line and off-line measurement techniques are discussed. This study was performed in the framework of Technical Working Area (TWA) 34—"Properties of Nanoparticle Populations" of the Versailles Project on Advanced Materials and Standards (VAMAS) in the project no. 3 "Techniques for characterizing size distribution of airborne nanoparticles". Two types of nano-aerosols, consisting of (1) one population of nanoparticles with a mean diameter between 30.3 and 39.0 nm and (2) two populations of non-agglomerated nanoparticles with mean diameters between, respectively, 36.2-46.6 nm and 80.2-89.8 nm, were generated for characterization measurements. Scanning mobility particle size spectrometers (SMPS) were used for on-line measurements of size distributions of the produced nano-aerosols. Transmission electron microscopy, scanning electron microscopy, and atomic force microscopy were used as off-line measurement techniques for nanoparticles characterization. Samples were deposited on appropriate supports such as grids, filters, and mica plates by electrostatic precipitation and a filtration technique using SMPS controlled generation upstream. The results of the main size distribution parameters (mean and mode diameters), obtained from several laboratories, were compared based on metrological approaches including metrological traceability, calibration, and evaluation of the measurement uncertainty. Internationally harmonized measurement procedures for airborne SiO2 nanoparticles characterization are proposed.
Electrochemical Nanoparticle Sizing Via Nano-Impacts: How Large a Nanoparticle Can be Measured?
Bartlett, Thomas R; Sokolov, Stanislav V; Compton, Richard G
2015-01-01
The field of nanoparticle (NP) sizing encompasses a wide array of techniques, with electron microscopy and dynamic light scattering (DLS) having become the established methods for NP quantification; however, these techniques are not always applicable. A new and rapidly developing method that addresses the limitations of these techniques is the electrochemical detection of NPs in solution. The ‘nano-impacts’ technique is an excellent and qualitative in situ method for nanoparticle characterization. Two complementary studies on silver and silver bromide nanoparticles (NPs) were used to assess the large radius limit of the nano-impact method for NP sizing. Noting that by definition a NP cannot be larger than 100 nm in diameter, we have shown that the method quantitatively sizes at the largest limit, the lower limit having been previously reported as ∼6 nm.1 PMID:26491639
NASA Technical Reports Server (NTRS)
Smith, J. L.
1983-01-01
Existing techniques were surveyed, an experimental procedure was developed, a laboratory test model was fabricated, limited data were recovered for proof of principle, and the relationship between particle size distribution and amplitude measurements was illustrated in an effort to develop a low cost, simplified optical technique for measuring particle size distributions and velocities in fluidized bed combustors and gasifiers. A He-Ne laser illuminated Rochi Rulings (range 10 to 500 lines per inch). Various samples of known particle size distributions were passed through the fringe pattern produced by the rulings. A photomultiplier tube converted light from the fringe volume to an electrical signal which was recorded using an oscilloscope and camera. The signal amplitudes were correlated against the known particle size distributions. The correlation holds true for various samples.
Endogenous Sex Steroid Hormones, Lipid Subfractions, and Ectopic Adiposity in Asian Indians.
Kim, Catherine; Kong, Shengchun; Krauss, Ronald M; Stanczyk, Frank Z; Reddy, Srinivasa T; Needham, Belinda L; Kanaya, Alka M
2015-12-01
Estradiol, testosterone (T), and sex hormone binding globulin (SHBG) levels are associated with lipid subfractions in men and women. Our objective was to determine if associations are independent from adipose tissue area among Asian Indians. We used data from 42 women and 57 Asian Indian men who did not use exogenous steroids or lipid-lowering medications. Lipoprotein subfractions including low-density lipoprotein cholesterol (LDL), very low-density lipoprotein cholesterol (VLDL), and intermediate density lipoprotein (IDL) were assessed by ion mobility spectrometry. Intra-abdominal adiposity was assessed by computed tomography. Multivariable regression models estimated the association between sex hormones with lipoprotein subfractions before and after adjustment for adiposity. Among women, lower logSHBG levels were associated with smaller logLDL particle size and higher logtriglycerides, logVLDL, and logIDL, although these associations were attenuated with adjustment for visceral adiposity in particular. Among women, lower logSHBG levels was significantly associated with lower logmedium LDL and logsmall LDL concentrations even after consideration of visceral and hepatic adiposity and insulin resistance as represented by the homeostasis model assessment of insulin resistance (HOMA-IR). Among men, lower logSHBG was also associated with smaller logLDL peak diameter size and higher logtriglycerides and logVLDL, even after adjustment for HOMA-IR and adiposity. Relationships between sex steroids and lipid subfractions were not significant among women. Among men, higher total testosterone was associated with higher logHDL and logLDL particle size, and lower logtriglycerides and logVLDL, but these associations were partially attenuated with adjustment for adiposity and HOMA-IR. Among Asian Indians, SHBG is associated with more favorable lipid subfraction concentrations, independent of hepatic and visceral fat.
Scollo, Michelle; Bayly, Megan; Wakefield, Melanie
2015-01-01
Objective This study monitored the advertised price of the most prominently promoted and the cheapest single packs of cigarettes in Australian retail outlets before and after the implementation of plain packaging. Methods A panel of 421 outlets in four large Australian cities was visited monthly from May 2012 to August 2013 and the brand, pack size and price of the most-prominently listed and lowest-priced single cigarette pack were recorded from each store's tobacco price board. Changes in the inflation-adjusted stick price were examined using linear mixed models, controlling for fixed effects of city, store type, area socioeconomic status and random effects of time. The adjusted stick price was also examined over time by tobacco manufacturer and pack size. Results The inflation-adjusted stick price of the most-prominently advertised single packs was significantly higher than in May–July 2012 from August–October 2012 for mainstream and premium brands and from February–April 2013 for value brands. Adjusted average stick prices of lowest-priced packs in August 2013 were $0.02 (95% CI $0.02 to $0.03, p<0.001) higher than in May–July 2012 ($Aug13). A large real increase in stick price was seen in February–April 2013 across all major manufacturers, market segments and pack size categories. Discussion The price of cigarettes most prominently promoted on price boards did not decrease in the months following implementation of Australia's plain packaging legislation. Retail prices continued to increase above the level resulting from automatic indexation of excise/customs duty even at the lowest-priced end of the Australian market. PMID:28407616
Perinatal mortality in second- vs firstborn twins: a matter of birth size or birth order?
Luo, Zhong-Cheng; Ouyang, Fengxiu; Zhang, Jun; Klebanoff, Mark
2014-08-01
Second-born twins on average weigh less than first-born twins and have been reported at an elevated risk of perinatal mortality. Whether the risk differences depend on their relative birth size is unknown. The present study aimed to evaluate the association of birth order with perinatal mortality by birth order-specific weight difference in twin pregnancies. In a retrospective cohort study of 258,800 twin pregnancies without reported congenital anomalies using the US matched multiple birth data 1995-2000 (the available largest multiple birth dataset), conditional logistic regression was applied to estimate the odds ratio (OR) of perinatal death adjusted for fetus-specific characteristics (sex, presentation, and birthweight for gestational age). Comparing second vs first twins, the risks of perinatal death were similar if they had similar birthweights (within 5%) and were increasingly higher if second twins weighed progressively less (adjusted ORs were 1.37, 1.90, and 3.94 if weighed 5.0-14.9%, 15.0-24.9%, and ≥25.0% less, respectively), and progressively lower if they weighed increasingly more (adjusted ORs were 0.67, 0.63, and 0.36 if weighed 5.0-14.9%, 15.0-24.9%, and ≥25.0% more, respectively) (all P < .001). The perinatal mortality rates were not significantly different in cesarean deliveries or preterm (<37 weeks) vaginal deliveries but were significantly higher in second twins in term vaginal deliveries (3.1 vs 1.8 per 1000; adjusted OR, 2.15; P < .001). Perinatal mortality risk differences in second vs first twins depend on their relative birth size. Vaginal delivery at term is associated with a substantially greater risk of perinatal mortality in second twins. Copyright © 2014 Mosby, Inc. All rights reserved.
2008-01-01
Purpose To compare two laser photocoagulation techniques for treatment of diabetic macular edema (DME): modified-ETDRS direct/grid photocoagulation (mETDRS) and a, potentially milder, but potentially more extensive, mild macular grid (MMG) laser technique in which small mild burns are placed throughout the macula, whether or not edema is present, and microaneurysms are not treated directly. Methods 263 subjects (mean age 59 years) with previously untreated DME were randomly assigned to receive laser photocoagulation by mETDRS (N=162 eyes) or MMG (N=161 eyes) technique. Visual acuity, fundus photographs and OCT measurements were obtained at baseline and after 3.5, 8, and 12 months. Treatment was repeated if DME persisted. Main Outcome Measure Change in OCT measures at 12-months follow up. Results From baseline to 12 months, among eyes with baseline central subfield thickness ≥ 250 microns, central subfield thickening decreased by an average of 88 microns in the mETDRS group and decreased by 49 microns in the MMG group (adjusted mean difference: 33 microns, 95% confidence interval 5 to 61 microns, P=0.02). Weighted inner zone thickening by OCT decreased by 42 and 28 microns, respectively (adjusted mean difference: 14 microns, 95% confidence interval 1 to 27 microns, P=0.04), maximum retinal thickening (maximum of the central and four inner subfields) decreased by 66 and 39 microns, respectively (adjusted mean difference: 27 microns, 95% confidence interval 6 to 47 microns, P=0.01), and retinal volume decreased by 0.8 and 0.4 mm3, respectively (adjusted mean difference: 0.3 mm3, 95% confidence interval 0.02 to 0.53 mm3, P=0.03). At 12 months, the mean change in visual acuity was 0 letters in the mETDRS group and 2 letters worse in the MMG group (adjusted mean difference: 2 letters, 95% confidence interval −0.5 to 5 letters, P=0.10). Conclusions At 12 months after treatment, the MMG technique is less effective at reducing OCT measured retinal thickening than the more extensively evaluated current mETDRS laser photocoagulation approach. However, the visual acuity outcome with both approaches is not substantially different. Given these findings a larger long-term trial of the MMG technique is not justified. Application to Clinical Practice Modified ETDRS focal photocoagulation should continue as a standard approach for treating diabetic macular edema. PMID:17420366
Male cleaner wrasses adjust punishment of female partners according to the stakes
Raihani, Nichola J.; Pinto, Ana I.; Grutter, Alexandra S.; Wismer, Sharon; Bshary, Redouan
2012-01-01
Punishment is an important deterrent against cheating in cooperative interactions. In humans, the severity of cheating affects the strength of punishment which, in turn, affects the punished individual's future behaviour. Here, we show such flexible adjustments for the first time in a non-human species, the cleaner wrasse (Labroides dimidiatus), where males are known to punish female partners. We exposed pairs of cleaners to a model client offering two types of food, preferred ‘prawn’ items and less-preferred ‘flake’ items. Analogous to interactions with real clients, eating a preferred prawn item (‘cheating’) led to model client removal. We varied the extent to which female cheating caused pay-off reduction to the male and measured the corresponding severity of male punishment. Males punished females more severely when females cheated during interactions with high value, rather than low value, model clients; and when females were similar in size to the male. This pattern may arise because, in this protogynous hermaphrodite, cheating by similar-sized females may reduce size differences to the extent that females change sex and become reproductive competitors. In response to more severe punishment from males, females behaved more cooperatively. Our results show that punishment can be adjusted to circumstances and that such subtleties can have an important bearing on the outcome of cooperative interactions. PMID:21676980
ERIC Educational Resources Information Center
Sekar, J. Master Arul; Lawrence, A.S. Arul
2016-01-01
The present study aims to investigate whether there is any significant relationship between adjustment and academic achievement of higher secondary school students. In this survey study, the investigators used stratified random sampling technique for selecting the sample from the population. The stratification was done on the basis of gender and…
ERIC Educational Resources Information Center
Xiong, Yiying; Zhou, Yuchun
2018-01-01
In this study, we explore East Asian graduate students' socio-cultural and psychological adjustment in a U.S. Midwestern University. Eight participants were interviewed about their acculturation challenges as well as their effective coping strategies. Data were analyzed using open-coding techniques and five themes emerged: three themes summarized…
Liese, Angela D; Crandell, Jamie L; Tooze, Janet A; Kipnis, Victor; Bell, Ronny; Couch, Sarah C; Dabelea, Dana; Crume, Tessa L; Mayer-Davis, Elizabeth J
2015-08-14
The SEARCH Nutrition Ancillary Study aims to investigate the role of dietary intake on the development of long-term complications of type 1 diabetes in youth, and capitalise on measurement error (ME) adjustment methodology. Using the National Cancer Institute (NCI) method for episodically consumed foods, we evaluated the relationship between sugar-sweetened beverage (SSB) intake and cardiovascular risk factor profile, with the application of ME adjustment methodology. The calibration sample included 166 youth with two FFQ and three 24 h dietary recall data within 1 month. The full sample included 2286 youth with type 1 diabetes. SSB intake was significantly associated with higher TAG, total and LDL-cholesterol concentrations, after adjusting for energy, age, diabetes duration, race/ethnicity, sex and education. The estimated effect size was larger (model coefficients increased approximately 3-fold) after the application of the NCI method than without adjustment for ME. Compared with individuals consuming one serving of SSB every 2 weeks, those who consumed one serving of SSB every 2 d had 3.7 mg/dl (0.04 mmol/l) higher TAG concentrations and 4.0 mg/dl (0.10 mmol/l) higher total cholesterol and LDL-cholesterol concentrations, after adjusting for ME and covariates. SSB intake was not associated with measures of adiposity and blood pressure. Our findings suggest that SSB intake is significantly related to increased lipid levels in youth with type 1 diabetes, and that estimates of the effect size of SSB on lipid levels are severely attenuated in the presence of ME. Future studies in youth with diabetes should consider a design that will allow for the adjustment for ME when studying the influence of diet on health status.
Koo, Brian B; Blackwell, Terri; Lee, Hochang B; Stone, Katie L; Louis, Elan D; Redline, Susan
2016-11-01
To investigate an association between restless legs syndrome (RLS) and depression and to what extent sleep disturbance, periodic limb movements during sleep (PLMS), and antidepressant medication mediate this relationship. A cross-sectional analysis was conducted of the Osteoporotic Fractures in Older Men Study data in 982 men assessed for RLS (International RLS Study Group scale [IRLSS]) and depression (Geriatric Depression Scale [GDS]), who underwent actigraphy (for sleep latency/efficiency) and polysomnography (for PLMS). Men were split into three groups: no RLS (N = 815), mild RLS (IRLSS ≤ 12, N = 85), moderate-to-severe RLS (IRLSS > 12, N = 82). Depression was defined as GDS score ≥ 6. Logistic and linear regression assessed associations of RLS and depression or number depressive symptoms, respectively. Models were adjusted for age, site, race, education, body mass index, personal habits, benzodiazepine/dopaminergic medication, physical activity, cardiovascular risk factors, and apnea-hypopnea index. Of 982 men, 167 (17.0%) had RLS. Depression was significantly associated with moderate-to-severe RLS after adjustment (versus no RLS: OR [95% CI] 2.85 [1.23, 6.64]). Further adjustment for potential mediators attenuated effect size modestly, most for sleep efficiency (OR: 2.85-2.55). Compared with no RLS, moderate-to-severe RLS was associated with the number of depressive symptoms after adjustment (adjusted means [95% CI]; no RLS: 1.14 [1.05, 1.24] versus IRLSS > 12: 1.69 [1.32, 2.11]). Further adjustment for potential mediators did not alter effect size. For men with PLMS index at least median, number of depressive symptoms significantly increased as RLS category became more severe. Depression is more common as RLS severity worsens. The RLS-depression relationship is modestly explained by sleep disturbance and PLMS. Published by Elsevier Inc.
Legros, S.; Mialet-Serra, I.; Caliman, J.-P.; Siregar, F. A.; Clement-Vidal, A.; Fabre, D.; Dingkuhn, M.
2009-01-01
Background and Aims Despite its simple architecture and small phenotypic plasticity, oil palm has complex phenology and source–sink interactions. Phytomers appear in regular succession but their development takes years, involving long lag periods between environmental influences and their effects on sinks. Plant adjustments to resulting source–sink imbalances are poorly understood. This study investigated oil palm adjustments to imbalances caused by severe fruit pruning. Methods An experiment with two treatments (control and complete fruit pruning) during 22 months in 2006–2008) and six replications per treatment was conducted in Indonesia. Phenology, growth of above-ground vegetative and reproductive organs, leaf morphology, inflorescence sex differentiation, dynamics of non-structural carbohydrate reserves and light-saturated net photosynthesis (Amax) were monitored. Key Results Artificial sink limitation by complete fruit pruning accelerated development rate, resulting in higher phytomer, leaf and inflorescence numbers. Leaf size and morphology remained unchanged. Complete fruit pruning also suppressed the abortion of male inflorescences, estimated to be triggered at about 16 months before bunch maturity. The number of female inflorescences increased after an estimated lag of 24–26 months, corresponding to time from sex differentiation to bunch maturity. The most important adjustment process was increased assimilate storage in the stem, attaining nearly 50 % of dry weight in the stem top, mainly as starch, whereas glucose, which in controls was the most abundant non-structural carbohydrate stored in oil palm, decreased. Conclusions The development rate of oil palm is in part controlled by source–sink relationships. Although increased rate of development and proportion of female inflorescences constituted observed adjustments to sink limitation, the low plasticity of plant architecture (constant leaf size, absence of branching) limited compensatory growth. Non-structural carbohydrate storage was thus the main adjustment process. PMID:19748908
NASA Astrophysics Data System (ADS)
Chuamchaitrakool, Porntip; Widjaja, Joewono; Yoshimura, Hiroyuki
2018-01-01
A method for improving accuracy in Wigner-Ville distribution (WVD)-based particle size measurements from inline holograms using flip and replication technique (FRT) is proposed. The FRT extends the length of hologram signals being analyzed, yielding better spatial-frequency resolution of the WVD output. Experimental results verify reduction in measurement error as the length of the hologram signals increases. The proposed method is suitable for particle sizing from holograms recorded using small-sized image sensors.
Three-dimensional image contrast using biospeckle
NASA Astrophysics Data System (ADS)
Godinho, Robson Pierangeli; Braga, Roberto A., Jr.
2010-09-01
The biospeckle laser (BSL) has been applied in many areas of knowledge and a variety of approaches has been presented to address the best results in biological and non-biological samples, in fast or slow activities, or else in defined flow of materials or in random activities. The methodologies accounted in the literature consider the apparatus used in the image assembling and the way the collected data is processed. The image processing steps presents in turn a variety of procedures with first or second order statistics analysis, and as well with different sizes of data collected. One way to access the biospeckle in defined flow, such as in capillary blood flow in alive animals, was the adoption of the image contrast technique which uses only one image from the illuminated sample. That approach presents some problems related to the resolution of the image, which is reduced during the image contrast processing. In order to help the visualization of the low resolution image formed by the contrast technique, this work presents the three-dimensional procedure as a reliable alternative to enhance the final image. The work based on a parallel processing, with the generation of a virtual map of amplitudes, and maintaining the quasi-online characteristic of the contrast technique. Therefore, it was possible to generate in the same display the observed material, the image contrast result and in addiction the three-dimensional image with adjustable options of rotation. The platform also offers to the user the possibility to access the 3D image offline.
Yong-Jiang Zhang; Frederick C. Meinzer; Guang-You Hao; Fabian G. Scholz; Sandra J. Bucci; Frederico S.C. Takahashi; Randol Villalobos-Vega; Juan P. Giraldo; Kun-Fang Cao; William A. Hoffmann; Guillermo Goldstein
2009-01-01
Size-related changes in hydraulic architecture, carbon allocation, and gas exchange of Sclerolobium paniculatum (Leguminosae), a dominant tree species in Neotropical savannas of central Brazil (Cerrado), were investigated to assess their potential role in the dieback of tall individuals. Trees greater than ~6 m tall exhibited more branch damage,...
Preparation of gold nanoparticles and determination of their particles size via different methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iqbal, Muhammad; Usanase, Gisele; Oulmi, Kafia
Graphical abstract: Preparation of gold nanoparticles via NaBH{sub 4} reduction method, and determination of their particle size, size distribution and morphology by using different techniques. - Highlights: • Gold nanoparticles were synthesized by NaBH{sub 4} reduction method. • Excess of reducing agent leads to tendency of aggregation. • The particle size, size distribution and morphology were investigated. • Particle size was determined both experimentally as well as theoretically. - Abstract: Gold nanoparticles have been used in various applications covering both electronics, biosensors, in vivo biomedical imaging and in vitro biomedical diagnosis. As a general requirement, gold nanoparticles should be preparedmore » in large scale, easy to be functionalized by chemical compound of by specific ligands or biomolecules. In this study, gold nanoparticles were prepared by using different concentrations of reducing agent (NaBH{sub 4}) in various formulations and their effect on the particle size, size distribution and morphology was investigated. Moreover, special attention has been dedicated to comparison of particles size measured by various techniques, such as, light scattering, transmission electron microscopy, UV spectrum using standard curve and particles size calculated by using Mie theory and UV spectrum of gold nanoparticles dispersion. Particle size determined by various techniques can be correlated for monodispersed particles and excess of reducing agent leads to increase in the particle size.« less
Kinematic synthesis of adjustable robotic mechanisms
NASA Astrophysics Data System (ADS)
Chuenchom, Thatchai
1993-01-01
Conventional hard automation, such as a linkage-based or a cam-driven system, provides high speed capability and repeatability but not the flexibility required in many industrial applications. The conventional mechanisms, that are typically single-degree-of-freedom systems, are being increasingly replaced by multi-degree-of-freedom multi-actuators driven by logic controllers. Although this new trend in sophistication provides greatly enhanced flexibility, there are many instances where the flexibility needs are exaggerated and the associated complexity is unnecessary. Traditional mechanism-based hard automation, on the other hand, neither can fulfill multi-task requirements nor are cost-effective mainly due to lack of methods and tools to design-in flexibility. This dissertation attempts to bridge this technological gap by developing Adjustable Robotic Mechanisms (ARM's) or 'programmable mechanisms' as a middle ground between high speed hard automation and expensive serial jointed-arm robots. This research introduces the concept of adjustable robotic mechanisms towards cost-effective manufacturing automation. A generalized analytical synthesis technique has been developed to support the computational design of ARM's that lays the theoretical foundation for synthesis of adjustable mechanisms. The synthesis method developed in this dissertation, called generalized adjustable dyad and triad synthesis, advances the well-known Burmester theory in kinematics to a new level. While this method provides planar solutions, a novel patented scheme is utilized for converting prescribed three-dimensional motion specifications into sets of planar projections. This provides an analytical and a computational tool for designing adjustable mechanisms that satisfy multiple sets of three-dimensional motion specifications. Several design issues were addressed, including adjustable parameter identification, branching defect, and mechanical errors. An efficient mathematical scheme for identification of adjustable member was also developed. The analytical synthesis techniques developed in this dissertation were successfully implemented in a graphic-intensive user-friendly computer program. A physical prototype of a general purpose adjustable robotic mechanism has been constructed to serve as a proof-of-concept model.
Chavhan, Govind B; Babyn, Paul S; Vasanawala, Shreyas S
2013-05-01
Familiarity with basic sequence properties and their trade-offs is necessary for radiologists performing abdominal magnetic resonance (MR) imaging. Acquiring diagnostic-quality MR images in the pediatric abdomen is challenging due to motion, inability to breath hold, varying patient size, and artifacts. Motion-compensation techniques (eg, respiratory gating, signal averaging, suppression of signal from moving tissue, swapping phase- and frequency-encoding directions, use of faster sequences with breath holding, parallel imaging, and radial k-space filling) can improve image quality. Each of these techniques is more suitable for use with certain sequences and acquisition planes and in specific situations and age groups. Different T1- and T2-weighted sequences work better in different age groups and with differing acquisition planes and have specific advantages and disadvantages. Dynamic imaging should be performed differently in younger children than in older children. In younger children, the sequence and the timing of dynamic phases need to be adjusted. Different sequences work better in smaller children and in older children because of differing breath-holding ability, breathing patterns, field of view, and use of sedation. Hence, specific protocols should be maintained for younger children and older children. Combining longer-higher-resolution sequences and faster-lower-resolution sequences helps acquire diagnostic-quality images in a reasonable time. © RSNA, 2013.
NASA Astrophysics Data System (ADS)
Castro Alves, D.; Abreu, Manuel; Cabral, A.; Jost, Michael; Rebordão, J. M.
2017-11-01
In this work we present a technique to perform long and absolute distance measurements based on mode-locked diode lasers. Using a Michelson interferometer, it is possible to produce an optical cross-correlation between laser pulses of the reference arm with the pulses from the measurement arm, adjusting externally their degree of overlap either changing the pulse repetition frequency (PRF) or the position of the reference arm mirror for two (or more) fixed frequencies. The correlation of the travelling pulses for precision distance measurements relies on ultra-short pulse durations, as the uncertainty associated to the method is dependent on the laser pulse width as well as on a highly stable PRF. Mode-locked Diode lasers are a very appealing technology for its inherent characteristics, associated to compactness, size and efficiency, constituting a positive trade-off with regard to other mode-locked laser sources. Nevertheless, main current drawback is the non-availability of frequency-stable laser diodes. The laser used is a monolithic mode-locked semiconductor quantum-dot (QD) laser. The laser PRF is locked to an external stabilized RF reference. In this work we will present some of the preliminary results and discuss the importance of the requirements related to laser PRF stability in the final metrology system accuracy.
Perceptually relevant parameters for virtual listening simulation of small room acoustics
Zahorik, Pavel
2009-01-01
Various physical aspects of room-acoustic simulation techniques have been extensively studied and refined, yet the perceptual attributes of the simulations have received relatively little attention. Here a method of evaluating the perceptual similarity between rooms is described and tested using 15 small-room simulations based on binaural room impulse responses (BRIRs) either measured from a real room or estimated using simple geometrical acoustic modeling techniques. Room size and surface absorption properties were varied, along with aspects of the virtual simulation including the use of individualized head-related transfer function (HRTF) measurements for spatial rendering. Although differences between BRIRs were evident in a variety of physical parameters, a multidimensional scaling analysis revealed that when at-the-ear signal levels were held constant, the rooms differed along just two perceptual dimensions: one related to reverberation time (T60) and one related to interaural coherence (IACC). Modeled rooms were found to differ from measured rooms in this perceptual space, but the differences were relatively small and should be easily correctable through adjustment of T60 and IACC in the model outputs. Results further suggest that spatial rendering using individualized HRTFs offers little benefit over nonindividualized HRTF rendering for room simulation applications where source direction is fixed. PMID:19640043
Novel fully integrated computer system for custom footwear: from 3D digitization to manufacturing
NASA Astrophysics Data System (ADS)
Houle, Pascal-Simon; Beaulieu, Eric; Liu, Zhaoheng
1998-03-01
This paper presents a recently developed custom footwear system, which integrates 3D digitization technology, range image fusion techniques, a 3D graphical environment for corrective actions, parametric curved surface representation and computer numerical control (CNC) machining. In this system, a support designed with the help of biomechanics experts can stabilize the foot in a correct and neutral position. The foot surface is then captured by a 3D camera using active ranging techniques. A software using a library of documented foot pathologies suggests corrective actions on the orthosis. Three kinds of deformations can be achieved. The first method uses previously scanned pad surfaces by our 3D scanner, which can be easily mapped onto the foot surface to locally modify the surface shape. The second kind of deformation is construction of B-Spline surfaces by manipulating control points and modifying knot vectors in a 3D graphical environment to build desired deformation. The last one is a manual electronic 3D pen, which may be of different shapes and sizes, and has an adjustable 'pressure' information. All applied deformations should respect a G1 surface continuity, which ensure that the surface can accustom a foot. Once the surface modification process is completed, the resulting data is sent to manufacturing software for CNC machining.
Yang, C L; Wei, H Y; Adler, A; Soleimani, M
2013-06-01
Electrical impedance tomography (EIT) is a fast and cost-effective technique to provide a tomographic conductivity image of a subject from boundary current-voltage data. This paper proposes a time and memory efficient method for solving a large scale 3D EIT inverse problem using a parallel conjugate gradient (CG) algorithm. The 3D EIT system with a large number of measurement data can produce a large size of Jacobian matrix; this could cause difficulties in computer storage and the inversion process. One of challenges in 3D EIT is to decrease the reconstruction time and memory usage, at the same time retaining the image quality. Firstly, a sparse matrix reduction technique is proposed using thresholding to set very small values of the Jacobian matrix to zero. By adjusting the Jacobian matrix into a sparse format, the element with zeros would be eliminated, which results in a saving of memory requirement. Secondly, a block-wise CG method for parallel reconstruction has been developed. The proposed method has been tested using simulated data as well as experimental test samples. Sparse Jacobian with a block-wise CG enables the large scale EIT problem to be solved efficiently. Image quality measures are presented to quantify the effect of sparse matrix reduction in reconstruction results.
Enhanced three-dimensional stochastic adjustment for combined volcano geodetic networks
NASA Astrophysics Data System (ADS)
Del Potro, R.; Muller, C.
2009-12-01
Volcano geodesy is unquestionably a necessary technique in studies of physical volcanology and for eruption early warning systems. However, as every volcano geodesist knows, obtaining measurements of the required resolution using traditional campaigns and techniques is time consuming and requires a large manpower. Moreover, most volcano geodetic networks worldwide use a combination of data from traditional techniques; levelling, electronic distance measurements (EDM), triangulation and Global Navigation Satellite Systems (GNSS) but, in most cases, these data are surveyed, analysed and adjusted independently. This then leaves it to the authors’ criteria to decide which technique renders the most realistic results in each case. Herein we present a way of solving the problem of inter-methodology data integration in a cost-effective manner following a methodology were all the geodetic data of a redundant, combined network (e.g. surveyed by GNSS, levelling, distance, angular data, INSAR, extensometers, etc.) is adjusted stochastically within a single three-dimensional referential frame. The adjustment methodology is based on the least mean square method and links the data with its geometrical component providing combined, precise, three-dimensional, displacement vectors, relative to external reference points as well as stochastically-quantified, benchmark-specific, uncertainty ellipsoids. Three steps in the adjustment allow identifying, and hence dismissing, flagrant measurement errors (antenna height, atmospheric effects, etc.), checking the consistency of external reference points and a final adjustment of the data. Moreover, since the statistical indicators can be obtained from expected uncertainties in the measurements of the different geodetic techniques used (i.e. independent of the measured data), it is possible to run a priori simulations of a geodetic network in order to constrain its resolution, and reduce logistics, before the network is even built. In this work we present a first effort to apply this technique to a new volcano geodetic network on Arenal volcano in Costa Rica, using triangulation, EDM and GNSS data from four campaigns. An a priori simulation, later confirmed by field measurements, of the movement detection capacity of different benchmarks within the network, shows how the network design is optimised to detect smaller displacement at the points where these are expected. Data from the four campaigns also proves the repeatability and consistency of the statistical indicators. A preliminary interpretation of the geodetic data relative to Arenal’s volcanic activity could indicate a correlation between displacement velocity and direction with the location and thickness of the recent lava flow field. This then suggests that a deflation caused by the weight of the lava field could be obscuring the effects of possible deep magmatic sources. Although this study is specific to Arenal volcano and its regional tectonic setting, we suggest that the cost-effective, high-quality results we present, prove the methodology’s potential to be incorporated into the design and analysis of volcano geodetic networks worldwide.
Determining the size of nanoparticles in the example of magnetic iron oxide core-shell systems
NASA Astrophysics Data System (ADS)
Jarzębski, Maciej; Kościński, Mikołaj; Białopiotrowicz, Tomasz
2017-08-01
The size of nanoparticles is one of the most important factors for their possible applications. Various techniques for the nanoparticle size characterization are available. In this paper selected techniques will be considered base on the prepared core-shell magnetite nanoparticles. Magnetite is one of the most investigated and developed magnetic material. It shows interesting magnetic properties which can be used for biomedical applications, such as drug delivery, hypothermia and also as a contrast agent. To reduce the toxic effects of Fe3O4, magnetic core was covered by dextran and gelatin. Moreover, the shell was doped by fluorescent dye for confocal microscopy investigation. The main investigation focused on the methods for particles size determination of modified magnetite nanoparticles prepared with different techniques. The size distribution were obtained by nanoparticle tracking analysis, dynamic light scattering and transmission electron microscopy. Furthermore, fluorescent correlation spectroscopy (FCS) and confocal microscopy were used to compare the results for particle size determination of core-shell systems.
NASA Technical Reports Server (NTRS)
Hess, C. F.; Smart, A. E.; Espinosa, V. E.
1985-01-01
An instrument to measure the size and velocity of droplets was developed. The instrument uses one of two techniques, as appropriate. In the first technique two small laser beams of one color identify the center of a larger laser beam of a different color. This defines a region of almost uniform intensity where the light scattered by the individual droplets can be related to their size. The first technique uses the visibility of a Doppler burst and validates it against the peak intensity of the signal's pedestal. Results are presented for monodisperse, bimodal, trimodal, and polydisperse sprays produced by the Berglund-Liu droplet generator and a pressure nozzle. Size distributions of a given spray obtained using three different size ranges show excellent self-consistency in the overlapping region. Measurements of sprays of known characteristics exhibit errors in the order of 10%. The principles of operation and design criteria of the instrument are discussed in great detail.