Jay, Ollie; Molgat-Seon, Yannick; Chou, Shirley; Murto, Kimmo
2013-12-01
The accurate measurement of core temperature is an essential aspect of intraoperative management in children. Invasive measurement sites are accurate but carry some health risks and cannot be used in certain patients. An accurate form of noninvasive thermometry is therefore needed. Our aim was to develop, and subsequently validate, separate models for estimating core temperature using different skin temperatures with an individualized correction factor. Forty-eight pediatric patients (0-36 months) undergoing elective surgery were separated into a modeling group (MG, n = 28) and validation group (VG, n = 20). Skin temperature was measured over the carotid artery (Tsk_carotid ), upper abdomen (Tsk_abd ), and axilla (Tsk_axilla ), while nasopharyngeal temperature (Tnaso ) was measured as a reference. In the MG, derived models for estimating Tnaso were: Tsk_carotid + 0.52; Tsk_abd + (0.076[body mass] + 0.02); and Tsk_axilla + (0.081[body mass]-0.66). After adjusting raw Tsk_carotid, Tsk_abd , and Tsk_axilla values in the independent VG using these models, the mean bias (Predicted Tnaso - Actual Tnaso [with 95% confidence intervals]) was +0.03[+0.53, -0.50]°C, -0.05[+1.02, -1.07]°C, and -0.06[+1.21, -1.28°C], respectively. The percentage of values within ±0.5°C of Tnaso was 93.2%, 75.4%, and 66.1% for Tsk_carotid, Tsk_abd , and Tsk_axilla , respectively. Sensitivity and specificity for detecting hypothermia (Tnaso < 36.0°C) was 0.88 and 0.91 for Tsk_carotid , 0.61 and 0.76 for Tsk_abd , and 0.91 and 0.73 for Tsk_axilla . Goodness-of-fit (R(2) ) relative to the line-of-identity was 0.74 (Tsk_carotid ), 0.34 (Tsk_abd ), and 0.15 (Tsk_axilla ). Skin temperature over the carotid artery, with a simple correction factor of +0.52°C, provides a viable noninvasive estimate of Tnaso in young children during elective surgery with a general anesthetic. © 2013 John Wiley & Sons Ltd.
Sleep and Skin Temperature in Preschool Children and Their Mothers.
Okamoto-Mizuno, Kazue; Mizuno, Koh; Shirakawa, Shuichiro
2018-01-01
The purpose of this study was to investigate and compare sleep and skin temperature (Tsk) of preschool children with those of their mothers. The subjects included 18 pairs of preschool children and their mothers. The actigraphic measurement of sleep, Tsk, heart rate, bedroom climate, and the microclimate temperature and humidity (bed climate) were measured. Proximal and distal Tsk, the temperature gradient of distal and proximal Tsk (DPG), and bed climate temperature were significantly lower in the children. Approximately 70% of the children slept without bed covering. Heat dissipation during sleep in preschool children may primarily rely on the proximal Tsk. The lower Tsk than adults, and behavioral thermoregulation, may be important for sleep in preschoolers.
NONINVASIVE, CONTINUOUS MEASUREMENT OF RAT TAIL SKIN TEMPERATURE BY RADIOTELEMETRY.
Tail skin temperature (Tsk) can provide a wealth of information on the thermoregulatory status of the rat. Drug- and toxic-induced changes in body temperature are often mediated by vasodilation or constriction of blood flow to the tail and Tsk can generally be used as an indica...
Estimation of thermal sensation during varied air temperature conditions.
Katsuura, T; Tabuchi, R; Iwanaga, K; Harada, H; Kikuchi, Y
1998-03-01
Seven male students were exposed to four varied air temperature environments: hot (37 degrees C) to neutral (27 degrees C) (HN), neutral to hot (NH), cool (17 degrees C) to neutral (CN), and neutral to cool (NC). The air temperature was maintained at the first condition for 20 min, then was changed to the second condition after 15 min and was held there for 20 min. Each subject wore a T-shirt, briefs, trunks, and socks. Each sat on a chair and was continuously evaluated for thermal sensation, thermal comfort, and air velocity sensation. Some physiological and thermal parameters were also measured every 5 s during the experiment. The correlation between thermal sensation and skin temperature at 15 sites was found to be poor. The subjects felt much warmer during the rising phase of the air temperature (CN, NH) than during the descending phase (HN, NC) at a given mean skin temperature. However, thermal sensation at the same heat flux or at the same value of the difference between skin and air temperature (delta(Tsk - Ta)) was not so different among the four experimental conditions, and the correlation between thermal sensation and heat flux or delta(Tsk - Ta) was fairly good. The multiple regression equation of the thermal sensation (TS) on 15 sites of skin temperature (Tsk; degrees C) was calculated and the coefficient of determination (R*2) was found to be 0.656. Higher coefficients of determination were found in the equations of thermal sensation for the heat flux (H; kcal.m-2.h-1) at the right and left thighs of the subjects and on delta(Tsk - Ta) (degrees C) at 4 sites. They were as follows: TS = 2.04 - 0.016 Hright - 0.036 Hleft; R*2 = 0.717, TS = 1.649 + 0.013 delta(Tsk - Ta)UpperArm - 0.036 delta(Tsk - Ta)Chest - 0.223 delta(Tsk - Ta)Thigh-0.083 delta(Tsk - Ta)LowerLeg; R*2 = 0.752, respectively.
Aoki, Ken; Zhao, Kun; Yamazaki, Fumio; Sone, Ryoko; Alvarez, Guy E; Kosiba, Wojciech A; Johnson, John M
2008-03-01
Humans and other diurnal species experience a fall in internal temperature (T(int)) at night, accompanied by increased melatonin and altered thermoregulatory control of skin blood flow (SkBF). Also, exogenous melatonin induces a fall in T(int), an increase in distal skin temperatures and altered control of the cutaneous active vasodilator system, suggesting an effect of melatonin on the control of SkBF. To test whether exogenous melatonin also affects the more tonically active vasoconstrictor system in glabrous and nonglabrous skin during cooling, healthy males (n = 9) underwent afternoon sessions of whole body skin temperature (T(sk)) cooling (water-perfused suits) after oral melatonin (Mel; 3 mg) or placebo (Cont). Cutaneous vascular conductance (CVC) was calculated from SkBF (laser Doppler flowmetry) and non-invasive blood pressure. Baseline T(int) was lower in Mel than in Cont (P < 0.01). During progressive reduction of T(sk) from 35 degrees C to 32 degrees C, forearm CVC was first significantly reduced at T(sk) of 34.33 +/- 0.01 degrees C (P < 0.05) in Cont. In contrast, CVC in Mel was not significantly reduced until T(sk) reached 33.33 +/- 0.01 degrees C (P < 0.01). The decrease in forearm CVC in Mel was significantly less than in Cont at T(sk) of 32.66 +/- 0.01 degrees C and lower (P < 0.05). In Mel, palmar CVC was significantly higher than in Cont above T(sk) of 33.33 +/- 0.01 degrees C, but not below. Thus exogenous melatonin blunts reflex vasoconstriction in nonglabrous skin and shifts vasoconstrictor system control to lower T(int). It provokes vasodilation in glabrous skin but does not suppress the sensitivity to falling T(sk). These findings suggest that by affecting the vasoconstrictor system, melatonin has a causal role in the nocturnal changes in body temperature and its control.
Thermoregulatory responses to skin wetting during prolonged treadmill running.
Bassett, D R; Nagle, F J; Mookerjee, S; Darr, K C; Ng, A V; Voss, S G; Napp, J P
1987-02-01
We examined the physiological responses to skin wetting during a 120-min level treadmill run to assess whether skin wetting would reduce the dehydration and the increase in core temperature associated with prolonged exercise. Testing was conducted in an environmental chamber (T = 29.5 degrees C, wind velocity = 3 m X sec-1) under two different humidity conditions (33 or 66% relative humidity). Ten male subjects performed two runs in each humidity condition; one served as a control run. The other included spraying the body with 50 ml of water (T = 29.5 degrees C) every 10 min. Spraying had no effect on rectal temperature (Tre), heart rate, oxygen consumption, perceived exertion, sweat loss, or percent change in plasma volume in both the humid and the dry conditions. Spraying produced a significant reduction in mean skin temperature (Tsk), which increased the (Tre - Tsk) gradient. At the same time, overall skin conductance (K) was decreased, presumably as a result of cutaneous vasoconstriction due to the low Tsk. Since heat transfer from the body's core to the skin is expressed by the equation: heat transfer = K X (Tre - Tsk) the spraying had no effect on heat transfer away from the core, and Tre remained unchanged.
MacRae, Braid A; Rossi, Rene Michel; Psikuta, Agnes; Spengler, Christina M; Annaheim, Simon
2018-06-05
Locally increasing evaporative resistance is one mechanism by which contact skin temperature (Tsk) sensors and their attachments may disturb the temperature of the skin site being measured. We aimed to determine the extent to which an obstruction of evaporation affects local Tsk during exercise-induced sweating and how this compares to the Tsk measured using a conventional contact Tsk sensor. Twelve adult males each completed one experimental session (~24°C, ~46 % relative humidity; RH) involving seated rest and exercise (cycle ergometer). Air velocity was ~0.5 m·s-1 during rest and ~1 m·s-1 during exercise. Tsk of the right posterolateral forearm was measured using fine-wire thermocouples (0.125 mm diameter; chosen for minimal sensor-related disturbance) under two concurrent experimental conditions: uncovered or directly covered by a moisture-impermeable matte-black aluminium foil (thickness 0.08 mm, area 15 mm x 22 mm). The adjacent Tsk was also measured using an iButton attached with a nonwoven medical tape. Changes in next-to-skin absolute vapour pressure were used to estimate the onset of sweating. During exercise, covered thermocouple temperatures were consistently warmer than those uncovered. These differences were small before the onset of sweating (0.1°C, p=0.16), but increased thereafter (0.6 and 1.0°C by minutes 15 and 30 of exercise, respectively; p≤0.03). For change scores from baseline rest, the iButton-measured Tsk was as much as 0.7°C warmer than uncovered and -0.4°C cooler than covered thermocouples during sweating, but differences were not statistically supported and with wide 95% limits of agreement (up to ±3.1°C). When delineated, a small obstruction of evaporation itself caused an overestimation of Tsk during exercise although, while demonstrable, these effects were less clear in the context of using a conventional contact Tsk sensor and attachment. © 2018 Institute of Physics and Engineering in Medicine.
Regional Skin Temperature Response to Moderate Aerobic Exercise Measured by Infrared Thermography
Fernandes, Alex de Andrade; Amorim, Paulo Roberto dos Santos; Brito, Ciro José; Sillero-Quintana, Manuel; Bouzas Marins, João Carlos
2016-01-01
Background: Infrared thermography (IRT) does not require contact with the skin, and it is a convenient, reliable and non-invasive technique that can be used for monitoring the skin temperature (TSK). Objectives: The aim of this study was to monitor the variations in the regional TSK during exercise on 28 regions of interest (ROIs) (forehead, face, chest, abdomen, back, lumbar, anterior and posterior neck, and posterior and anterior views of the right and left hands, forearms, upper arms, thighs, and legs) with IRT. Patients and Methods: 12 physically active young males were monitored with IRT during the following three phases: a) 30 minutes before exercise b) while performing one hour of moderate intensity exercise on a treadmill at 60% of the VO2max, and c) 60 minutes after exercise. Results: During pre-exercise, all TSK reached a steady-state (P ≤ 0.05), which ensured adequate thermal stabilisation. At the beginning of exercise, there was a significant reduction in the TSK in most ROIs after 10 minutes of activity, except for the lower limbs (legs and thighs). After one hour of recovery, in the anterior view of the hands and thighs and in the posterior view of the legs, there were significant increases in the TSK compared to pre-exercise. Conclusions: There were significant distinctions in the skin temperature distribution during exercise according to the activity of the area under consideration during exercise, which may be important in the development of physiological models and heat flux analyses for different purposes. PMID:27217931
Bach, Aaron J. E.; Stewart, Ian B.; Disher, Alice E.; Costello, Joseph T.
2015-01-01
Purpose Skin temperature assessment has historically been undertaken with conductive devices affixed to the skin. With the development of technology, infrared devices are increasingly utilised in the measurement of skin temperature. Therefore, our purpose was to evaluate the agreement between four skin temperature devices at rest, during exercise in the heat, and recovery. Methods Mean skin temperature (T-sk) was assessed in thirty healthy males during 30 min rest (24.0 ± 1.2°C, 56 ± 8%), 30 min cycle in the heat (38.0 ± 0.5°C, 41 ± 2%), and 45 min recovery (24.0 ± 1.3°C, 56 ± 9%). T-sk was assessed at four sites using two conductive devices (thermistors, iButtons) and two infrared devices (infrared thermometer, infrared camera). Results Bland–Altman plots demonstrated mean bias ± limits of agreement between the thermistors and iButtons as follows (rest, exercise, recovery): -0.01 ± 0.04, 0.26 ± 0.85, -0.37 ± 0.98°C; thermistors and infrared thermometer: 0.34 ± 0.44, -0.44 ± 1.23, -1.04 ± 1.75°C; thermistors and infrared camera (rest, recovery): 0.83 ± 0.77, 1.88 ± 1.87°C. Pairwise comparisons of T-sk found significant differences (p < 0.05) between thermistors and both infrared devices during resting conditions, and significant differences between the thermistors and all other devices tested during exercise in the heat and recovery. Conclusions These results indicate poor agreement between conductive and infrared devices at rest, during exercise in the heat, and subsequent recovery. Infrared devices may not be suitable for monitoring T-sk in the presence of, or following, metabolic and environmental induced heat stress. PMID:25659140
Effects of season on sleep and skin temperature in the elderly
NASA Astrophysics Data System (ADS)
Okamoto-Mizuno, Kazue; Tsuzuki, Kazuyo
2010-07-01
The effects of season on sleep and skin temperature (Tsk) in 19 healthy, elderly volunteers were investigated. Measurements were obtained in summer, winter, and fall, and activity levels were monitored using a wrist actigraph system for five consecutive days. The temperature and humidity of the bedrooms of the subjects’ homes were measured continuously for five days. During actigraphic measurement, Tsk during sleep was measured for two nights. The bedroom temperature and humidity significantly increased in summer compared to winter and fall. In summer, the total sleep time decreased (mean ± SE min; summer, 350.8 ± 15.7; winter, 426.5 ± 14.2; fall, 403.2 ± 16.4) and wakefulness increased ( P < 0.003) compared to those in fall or winter. The sleep efficiency index that was derived from wrist actigraphy was significantly decreased ( P < 0.001) in summer (81.4 ± 2.9%) compared with winter (91.6 ± 1.3%) or fall (90.2 ± 1.2%). The forehead Tsk significantly increased, while the chest and thigh Tsks were decreased in summer compared to those in fall or winter. These results suggest that, in the elderly, sleep is disturbed in summer more than in other seasons, and that this disturbance is related to fluctuations in Tsk.
Nitroglycerin-induced changes in facial skin temperature: 'cold nose' as a predictor of headache?
Zaproudina, Nina; Närhi, Matti; Lipponen, Jukka A; Tarvainen, Mika P; Karjalainen, Pasi A; Karhu, Jari; Airaksinen, Olavi; Giniatullin, Rashid
2013-11-01
Nitroglycerin (NTG) often induces headaches when used to treat cardiac diseases. Such property of NTG has been widely used in modelling of migraine-like headaches. However, background reasons, predisposing to the development of NTG-headache, are less studied. The main aim of our study was to find, using NTG model, easily accessible markers of the vascular changes associated with headache. Because changes in the blood flow alter the local skin temperature (Tsk), we studied the relationship between the regional changes in the facial Tsk and NTG-induced headaches. Tsk was measured with infrared thermography in 11 healthy women during 3 h after sublingual NTG administration. NTG caused headache in five women, and four of them were the first-degree relatives of migraine patients. Notably, before NTG administration, subjects in the headache group had lower Tsk values, especially in the nose area, than women in the pain-free group (n = 6). NTG-induced headache was associated with a long-lasting increase of Tsk over the baseline. In sharp contrast, in the pain-free group, the Tsk reduced and returned rapidly to the baseline. Thus, the low baseline level and greater increase of regional Tsk correlated with the incidence of headache that supports a role of greater vascular changes in headache happening on the basis of the dissimilarities in vascular tone. An easily accessible phenomenon of 'cold nose' may indicate background vascular dysfunctions in individuals with predisposition to headache. Facial infrared thermography, coupled with NTG administration, suggests a novel temporally controlled approach for non-invasive investigation of vascular processes accompanying headaches. © 2013 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
Demachi, Koichi; Yoshida, Tetsuya; Tsuneoka, Hideyuki
2012-03-01
The aim of this study was to assess whether the three-compartment model of mean body temperature (Tb3) calculated from the esophageal temperature (Tes), temperature in deep tissue of exercising muscle (Tdt), and mean skin temperature (Tsk) has the potential to provide a better match with the thermoregulatory responses than the two-component model of mean body temperature (Tb2) calculated from Tes and Tsk. Seven male subjects performed 40 min of a prolonged cycling exercise at 30% maximal oxygen uptake at 21°C or 31°C (50% relative humidity). Throughout the experiment, Tsk, Tb2, Tb3, and Tdt were significantly (P < 0.01) lower at 21°C than at 31°C temperature conditions, while Tes was similar under both conditions. During exercise, an increase in cutaneous vascular conductance (skin blood flow / mean arterial pressure) over the chest (%CVCc) was observed at both 21°C and 31°C, while no increase was observed at the forearm at 21°C. Furthermore, the Tb3 and Tdt threshold for the onset of the increase in %CVCc was similar, but the Tes and Tb2 threshold differed significantly (P < 0.05) between the conditions tested. These results suggest that active cutaneous vasodilation at the chest is related more closely to Tb3 or Tdt than that measured by Tes or Tb2 calculated by Tes and Tsk during exercise at both 21°C and 31°C.
The determinants of thermal comfort in cool water.
Guéritée, J; House, J R; Redortier, B; Tipton, M J
2015-10-01
Water-based activities may result in the loss of thermal comfort (TC). We hypothesized that in cooling water, the hands and feet would be responsible. Supine immersions were conducted in up to five clothing conditions (exposing various regions), as well as investigations to determine if a "reference" skin temperature (Tsk) distribution in thermoneutral air would help interpret our findings. After 10 min in 34.5 °C water, the temperature was decreased to 19.5 °C over 20 min; eight resting or exercising volunteers reported when they no longer felt comfortable and which region was responsible. TC, rectal temperature, and Tsk were measured. Rather than the extremities, the lower back and chest caused the loss of overall TC. At this point, mean (SD) chest Tsk was 3.3 (1.7) °C lower than the reference temperature (P = 0.005), and 3.8 (1.5) °C lower for the back (P = 0.002). Finger Tsk was 3.1 (2.7) °C higher than the reference temperature (P = 0.037). In cool and cooling water, hands and feet, already adapted to colder air temperatures, will not cause discomfort. Contrarily, more discomfort may arise from the chest and lower back, as these regions cool by more than normal. Thus, Tsk distribution in thermoneutral air may help understand variations in TC responses across the body. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Thermoregulation in Erythrocebus patas - A thermal balance study
NASA Technical Reports Server (NTRS)
Kolka, M. A.; Elizondo, R. S.
1983-01-01
The ability of nonacclimated patas monkeys (Erythrocebus patas) to maintain a constant core temperature at six ambient temperatures from 15 to 40 C is investigated experimentally in 3 male and 3 female animals weighing 3.9-6.0 kg. The monkeys were permitted to reach equilibrium at the test Ta for at least 2 h before O2-uptake, CO2 output, weighted skin temperature (Tsk), rectal temperature (Tre), respiratory evaporative water loss (Eresp) and total evaporative water loss (Etot) were measured for 30 min. The results are presented in tables and graphs. Tsk is found to vary (from about 30.7 to about 37.2 C) with Ta, while Tre increases only from 37.6 to 38.4 C; Etot increases from about 9 to about 76 W/sq m, mainly due to eccrine sweating. Total body conductance, Tsk, and Tre are shown to be lower (the conductance significantly) at 40 C than those of rhesus monkeys. It is suggested that the enhanced heat tolerance of E. patas makes this species an appropriate subject for further studies of primate temperature regulation.
Thermoregulation in Erythrocebus patas: a thermal balance study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kolka, M.A.; Elizondo, R.S.
1983-11-01
The ability of nonacclimated patas monkeys (Erythrocebus patas) to maintain a constant core temperature at six ambient temperatures from 15 to 40 C is investigated experimentally in 3 male and 3 female animals weighing 3.9-6.0 kg. The monkeys were permitted to reach equilibrium at the test Ta for at least 2 h before O2-uptake, CO2 output, weighted skin temperature (Tsk), rectal temperature (Tre), respiratory evaporative water loss (Eresp) and total evaporative water loss (Etot) were measured for 30 min. The results are presented in tables and graphs. Tsk is found to vary (from about 30.7 to about 37.2 C) withmore » Ta, while Tre increases only from 37.6 to 38.4 C Etot increases from about 9 to about 76 W/sq m, mainly due to eccrine sweating. Total body conductance, Tsk, and Tre are shown to be lower (the conductance significantly) at 40 C than those of rhesus monkeys. It is suggested that the enhanced heat tolerance of E. patas makes this species an appropriate subject for further studies of primate temperature regulation.« less
Skin temperature modifies the impact of hypohydration on aerobic performance.
Kenefick, R W; Cheuvront, S N; Palombo, L J; Ely, B R; Sawka, M N
2010-07-01
This study determined the effects of hypohydration on aerobic performance in compensable [evaporative cooling requirement (E(req)) < maximal evaporative cooling (E(max))] conditions of 10 degrees C [7 degrees C wet bulb globe temperature (WBGT)], 20 degrees C (16 degrees C WBGT), 30 degrees C (22 degrees C WBGT), and 40 degrees C (27 degrees C WBGT) ambient temperature (T(a)). Our hypothesis was that 4% hypohydration would impair aerobic performance to a greater extent with increasing heat stress. Thirty-two men [22 +/- 4 yr old, 45 +/- 8 ml.kg(-1).min(-1) peak O(2) uptake (Vo(2 peak))] were divided into four matched cohorts (n = 8) and tested at one of four T(a) in euhydrated (EU) and hypohydrated (HYPO, -4% body mass) conditions. Subjects completed 30 min of preload exercise (cycle ergometer, 50% Vo(2 peak)) followed by a 15 min self-paced time trial. Time-trial performance (total work, change from EU) was -3% (P = 0.1), -5% (P = 0.06), -12% (P < 0.05), and -23% (P < 0.05) in 10 degrees C, 20 degrees C, 30 degrees C, and 40 degrees C T(a), respectively. During preload exercise, skin temperature (T(sk)) increased by approximately 4 degrees C per 10 degrees C T(a), while core (rectal) temperature (T(re)) values were similar within EU and HYPO conditions across all T(a). A significant relationship (P < 0.05, r = 0.61) was found between T(sk) and the percent decrement in time-trial performance. During preload exercise, hypohydration generally blunted the increases in cardiac output and blood pressure while reducing blood volume over time in 30 degrees C and 40 degrees C T(a). Our conclusions are as follows: 1) hypohydration degrades aerobic performance to a greater extent with increasing heat stress; 2) when T(sk) is >29 degrees C, 4% hypohydration degrades aerobic performance by approximately 1.6% for each additional 1 degrees C T(sk); and 3) cardiovascular strain from high skin blood flow requirements combined with blood volume reductions induced by hypohydration is an important contributor to impaired performance.
Correction of the heat loss method for calculating clothing real evaporative resistance.
Wang, Faming; Zhang, Chengjiao; Lu, Yehu
2015-08-01
In the so-called isothermal condition (i.e., Tair [air temperature]=Tmanikin [manikin temperature]=Tr [radiant temperature]), the actual energy used for moisture evaporation detected by most sweating manikins was underestimated due to the uncontrolled fabric 'skin' temperature Tsk,f (i.e., Tsk,f
LOCAL AND GLOBAL THERMOREGULATORY RESPONSES TO MRI ELECTROMAGNETIC FIELDS
Current U.S. exposure guidelines restrict core temperature (Tc) from increasing over 1.0 degrees C and skin temperature (Tsk) from exceeding 40 degrees C during MR. mall number of studies suggest that these limits are not reached in most clinical scans. AR's of < 0.4 W/kg have li...
Mechanisms of aerobic performance impairment with heat stress and dehydration.
Cheuvront, Samuel N; Kenefick, Robert W; Montain, Scott J; Sawka, Michael N
2010-12-01
Environmental heat stress can challenge the limits of human cardiovascular and temperature regulation, body fluid balance, and thus aerobic performance. This minireview proposes that the cardiovascular adjustments accompanying high skin temperatures (T(sk)), alone or in combination with high core body temperatures (T(c)), provide a primary explanation for impaired aerobic exercise performance in warm-hot environments. The independent (T(sk)) and combined (T(sk) + T(c)) effects of hyperthermia reduce maximal oxygen uptake (Vo(2max)), which leads to higher relative exercise intensity and an exponential decline in aerobic performance at any given exercise workload. Greater relative exercise intensity increases cardiovascular strain, which is a prominent mediator of rated perceived exertion. As a consequence, incremental or constant-rate exercise is more difficult to sustain (earlier fatigue) or requires a slowing of self-paced exercise to achieve a similar sensation of effort. It is proposed that high T(sk) and T(c) impair aerobic performance in tandem primarily through elevated cardiovascular strain, rather than a deterioration in central nervous system (CNS) function or skeletal muscle metabolism. Evaporative sweating is the principal means of heat loss in warm-hot environments where sweat losses frequently exceed fluid intakes. When dehydration exceeds 3% of total body water (2% of body mass) then aerobic performance is consistently impaired independent and additive to heat stress. Dehydration augments hyperthermia and plasma volume reductions, which combine to accentuate cardiovascular strain and reduce Vo(2max). Importantly, the negative performance consequences of dehydration worsen as T(sk) increases.
Effects of thermal underwear on thermal and subjective responses in winter.
Choi, Jeong-Wha; Lee, Joo-Young; Kim, So-Young
2003-01-01
This study was conducted to obtain basic data in improving the health of Koreans, saving energy and protecting environments. This study investigated the effects of wearing thermal underwear for keeping warm in the office in winter where temperature is not as low as affecting work efficiency, on thermoregulatory responses and subjective sensations. In order to create an environment where every subject feels the same thermal sensation, two experimental conditions were selected through preliminary experiments: wearing thermal underwear in 18 degrees C air (18-condition) and not wearing thermal underwear in 23 degrees C air (23-condition). Six healthy male students participated in this study as experiment subjects. Measurement items included rectal temperature (T(re)), skin temperature (T(sk)), clothing microclimate temperature (T(cm)), thermal sensation and thermal comfort. The results are as follows: (1) T(re) of all subjects was maintained constant at 37.1 degrees C under both conditions, indicating no significant differences. (2) (T)(sk) under the 18-condition and the 23-condition were 32.9 degrees C and 33.7 degrees C, respectively, indicating a significant level of difference (p<0.05). (3) Among local skin temperature, trunk part (forehead and abdomen) did not show significant differences. After 90-min exposure, the skin temperature of hands and feet under the 18-condition was significantly lower than that under the 23-condition (p<0.001). (4) More than 80% of all the respondents felt comfortable under both conditions. It was found (T)(sk) decreased due to a drop in the skin temperature of hands and feet, and the subjects felt cooler wearing only one layer of normal thermal underwear at 18 degrees C. Yet, the thermal comfort level, T(re) and T(cm) of chest part under the 18-condition were the same as those under the 23-condition. These results show that the same level of comfort, T(re) and T(cm) can be maintained as that of an environment about 5 degrees C higher in the office in winter, by wearing one layer of thermal underwear. In this regard, this study suggests that lowering indoor temperature by wearing thermal underwear in winter can contribute to saving energy and improving health.
Regional thermal comfort zone in males and females.
Ciuha, Ursa; Mekjavic, Igor B
2016-07-01
Skin regions differ in their sensitivity to temperature stimuli. The present study examined whether such regional differences were also evident in the perception of thermal comfort. Regional thermal comfort was assessed in males (N=8) and females (N=8), by having them regulate the temperature of the water delivered to a water-perfused suit (WPS), within a temperature range considered thermally comfortable. In separate trials, subjects regulated the temperature of the WPS, or specific regions of the suit covering different skin areas (arms, legs, front torso and back torso). In the absence of subjective temperature regulation (TR), the temperature changed in a sinusoidal manner from 10°C to 50°C; by depressing a switch and reversing the direction of the temperature at the limits of the thermal comfort zone (TCZ), each subject defined TCZ for each body region investigated. The range of regulated temperatures did not differ between genders and skin regions. Local Tsk at the lower and upper limits of the TCZ was similar for both genders. Higher (p<0.05) local Tsk was preferred for the arms (35.4±2.1°C), compared to other regions (legs: 34.4±5.4°C, front torso: 34.6±2.8°C, 34.3±6.6°C), irrespective of gender. In thermally comfortable conditions, the well-established regional differences in thermosensitivity are not reflected in the TCZ, with similar temperature preferences by both genders. Thermal comfort of different skin regions and overall body is not achieved at a single skin temperature, but at range of temperatures, defined as the TCZ. Copyright © 2016 Elsevier Inc. All rights reserved.
Vasomotor response of the human face: laser-Doppler measurements during mild hypo- and hyperthermia.
Rasch, W; Cabanac, M
1993-04-01
The skin of the face is reputed not to vasoconstrict in response to cold stress because the face skin temperature remains steady during hypothermia. The purpose of the present work was to measure the vasomotor response of the human face to whole-body hypothermia, and to compare it with hyperthermia. Six male subjects were immersed in cold and in warm water to obtain the two conditions. Skin blood flow, evaporation, and skin temperature (Tsk) were recorded in three loci of the face, the forehead, the infra orbital area, and the cheek. Tympanic (Tty) and oesophageal (Toes) temperatures were also recorded during the different thermal states. Normothermic measurements served as control. Blood flow was recorded with a laser-Doppler flowmeter, evaporation measured with an evaporimeter. Face Tsk remained stable between normo-, hypo-, and hyperthermia. Facial blood flow, however, did not follow the same pattern. The facial blood flow remained at minimal vasoconstricted level when the subjects' condition was changed from normo- to hypothermia. When the condition changed from hypo- to hyperthermia a 3 to 9-fold increase in the blood flow was recorded. From these results it was concluded that a vasoconstriction seems to be the general vasomotor state in the face during normothermia.
NASA Technical Reports Server (NTRS)
Draper, Clara; Reichle, Rolf; De Lannoy, Gabrielle; Scarino, Benjamin
2015-01-01
In land data assimilation, bias in the observation-minus-forecast (O-F) residuals is typically removed from the observations prior to assimilation by rescaling the observations to have the same long-term mean (and higher-order moments) as the corresponding model forecasts. Such observation rescaling approaches require a long record of observed and forecast estimates, and an assumption that the O-F mean differences are stationary. A two-stage observation bias and state estimation filter is presented, as an alternative to observation rescaling that does not require a long data record or assume stationary O-F mean differences. The two-stage filter removes dynamic (nonstationary) estimates of the seasonal scale O-F mean difference from the assimilated observations, allowing the assimilation to correct the model for synoptic-scale errors without adverse effects from observation biases. The two-stage filter is demonstrated by assimilating geostationary skin temperature (Tsk) observations into the Catchment land surface model. Global maps of the O-F mean differences are presented, and the two-stage filter is evaluated for one year over the Americas. The two-stage filter effectively removed the Tsk O-F mean differences, for example the GOES-West O-F mean difference at 21:00 UTC was reduced from 5.1 K for a bias-blind assimilation to 0.3 K. Compared to independent in situ and remotely sensed Tsk observations, the two-stage assimilation reduced the unbiased Root Mean Square Difference (ubRMSD) of the modeled Tsk by 10 of the open-loop values.
Cold sensitivity test for individuals with non-freezing cold injury: the effect of prior exercise
2013-01-01
Background One of the chronic symptoms of non-freezing cold injury (NFCI) is cold sensitivity. This study examined the effects of prior exercise on the response to a cold sensitivity test (CST) in NFCI patients with the aim of improving diagnostic accuracy. Methods Twenty three participants, previously diagnosed with NFCI by a Cold Injuries Clinic, undertook two CSTs. Participants either rested (air temperature 31°C) for approximately 80 min (prior rest condition (REST)) or rested for 30 min before exercising gently for 12 min (prior exercise condition (EX)). Following REST and EX, the participants placed their injured foot, covered in a plastic bag, into 15°C water for 2 min; this was followed by spontaneous rewarming in 31°C air for 10 min. Results The great toe skin temperature (Tsk) before immersion averaged 32.5 (3.4)°C in both conditions. Following immersion, the rate of rewarming of the great toe Tsk was faster in EX compared to REST and was higher 5 min (31.7 (3.4)°C vs. 29.8 (3.4)°C) and 10 min (33.8 (4.0)°C vs. 32.0 (4.0)°C) post-immersion. Over the first 5 min of rewarming, changes in the great toe Tsk correlated with the changes in skin blood flow (SkBF) in EX but not the REST condition. No relationship was observed between Tsk in either CST and the severity of NFCI as independently clinically assessed. Conclusions Exercise prior to the CST increased the rate of the toe Tsk rewarming, and this correlated with the changes in SkBF. However, the CST cannot be used in isolation in the diagnosis of NFCI, although the EX CST may prove useful in assessing the severity of post-injury cold sensitivity for prognostic and medico-legal purposes. PMID:23849038
Romanovsky, Andrej A; Ivanov, Andrei I; Shimansky, Yury P
2002-06-01
There is a misbelief that the same animal has the same thermoneutral zone (TNZ) in different experimental setups. In reality, TNZ strongly depends on the physical environment and varies widely across setups. Current methods for determining TNZ require elaborate equipment and can be applied only to a limited set of experimental conditions. A new, broadly applicable approach that rapidly determines whether given conditions are neutral for a given animal is needed. Consistent with the definition of TNZ [the range of ambient temperature (T(a)) at which body core temperature (T(c)) regulation is achieved only by control of sensible heat loss], we propose three criteria of thermoneutrality: 1) the presence of high-magnitude fluctuations in skin temperature (T(sk)) of body parts serving as specialized heat exchangers with the environment (e.g., rat tail), 2) the closeness of T(sk) to the median of its operational range, and 3) a strong negative correlation between T(sk) and T(c). Thermocouple thermometry and liquid crystal thermography were performed in five rat strains at 13 T(a). Under the conditions tested (no bedding or filter tops, no group thermoregulation), the T(a) range of 29.5-30.5 degrees C satisfied all three TNZ criteria in Wistar, BDIX, Long-Evans, and Zucker lean rats; Zucker fatty rats had a slightly lower TNZ (28.0-29.0 degrees C). Skin thermometry or thermography is a definition-based, simple, and inexpensive technique to determine whether experimental or housing conditions are neutral, subneutral, or supraneutral for a given animal.
NASA Astrophysics Data System (ADS)
Katiyatiya, C. L. F.; Muchenje, V.
2017-12-01
Breed, age, coat colour, month and temperature humidity index (THI) influence on body weight (W), body condition score (BCS), thermophysiological variables (rectal temperature (Tr), skin temperature (Tsk)) and hair length was studied in Nguni ( n = 19) and Boran ( n = 16). As a result of this study, breed influenced W, BCS and Tsk on the neck and belly ( P < 0.05). The BCS and W of Nguni cows were higher than the Boran cows. Hair length of both breeds increased from February to August. The THI influenced thermophysiological variables ( P < 0.05). Increased Tr for both breeds was recorded in February and April, respectively ( P < 0.05). Month influenced Tsk and June recorded lower values ( P < 0.05). Younger cows (3-8 years) had lower weight and high Tr and Tsk ( P < 0.05). Nguni cows had high neck and thurl temperatures in June while Boran cows had the highest in August ( P < 0.05). Red, dun and white-black Boran cows had increased BCS. Nguni cows with red, fawn and white cows had high BCS. Fawn-coloured Nguni cows and white-brown Boran cows had the more weight than cows with other colours compared in the study. White-red Nguni and Boran cows recorded the highest Tr. For Nguni cows, neck and belly temperatures were significantly ( P < 0.001) correlated to thurl temperature. Boran cows had significant ( P < 0.001) correlations for THI and neck, belly and thurl temperatures. The current study found that Nguni cows were more adapted to the prevailing bioclimatic changes. However, Boran cows have the potential of performing well under heat stress conditions over time.
Critical body temperature profile as indicator of heat stress vulnerability.
Nag, P K; Dutta, Priya; Nag, Anjali
2013-01-01
Extreme climatic heat is a major health concern among workers in different occupational pursuits. People in the regions of western India confront frequent heat emergencies, with great risk of mortality and morbidity. Taking account of informal occupational groups (foundry and sheet metal, FSM, N=587; ceramic and pottery, CP, N=426; stone quarry, SQ, N=934) in different seasons, the study examined the body temperature profiling as indicator of vulnerability to environmental warmth. About 3/4th of 1947 workers had habitual exposure at 30.1-35.5°C WBGT and ~10% of them were exposed to 38.2-41.6°C WBGT. The responses of FSM, CP and SQ workers indicated prevailing high heat load during summer and post-monsoon months. Local skin temperatures (T(sk)) varied significantly in different seasons, with consistently high level in summer, followed by post-monsoon and winter months. The mean difference of T(cr) and T(sk) was ~5.2°C up to 26.7°C WBGT, and ~2.5°C beyond 30°C WBGT. Nearly 90% of the workers had T(cr) within 38°C, suggesting their self-adjustment strategy in pacing work and regulating T(cr). In extreme heat, the limit of peripheral adjustability (35-36°C T(sk)) and the narrowing down of the difference between T(cr) and T(sk) might indicate the limit of one's ability to withstand heat exposure.
Zaidi, Maria; Krolikowki, John G; Jones, Deron W; Pritchard, Kirkwood A; Struve, Janine; Nandedkar, Sandhya D; Lohr, Nicole L; Pagel, Paul S; Weihrauch, Dorothée
2013-01-01
The tight skin mouse (Tsk(-/+)) is a model of scleroderma characterized by impaired vasoreactivity, increased oxidative stress, attenuated angiogenic response to VEGF and production of the angiogenesis inhibitor angiostatin. Low-level light therapy (LLLT) stimulates angiogenesis in myocardial infarction and chemotherapy-induced mucositis. We hypothesize that repetitive LLLT restores vessel growth in the ischemic hindlimb of Tsk(-/+) mice by attenuating angiostatin and enhancing angiomotin effects in vivo. C57Bl/6J and Tsk(-/+) mice underwent ligation of the femoral artery. Relative blood flow to the foot was measured using a laser Doppler imager. Tsk(-/+) mice received LLLT (670 nm, 50 mW cm(-2), 30 J cm(-2)) for 10 min per day for 14 days. Vascular density was determined using lycopersicom lectin staining. Immunofluorescent labeling, Western blot analysis and immunoprecipitation were used to determine angiostatin and angiomotin expression. Recovery of blood flow to the ischemic limb was reduced in Tsk(-/+) compared with C57Bl/6 mice 2 weeks after surgery. LLLT treatment of Tsk(-/+) mice restored blood flow to levels observed in C57Bl/6 mice. Vascular density was decreased, angiostatin expression was enhanced and angiomotin depressed in the ischemic hindlimb of Tsk(-/+) mice. LLLT treatment reversed these abnormalities. LLLT stimulates angiogenesis by increasing angiomotin and decreasing angiostatin expression in the ischemic hindlimb of Tsk(-/+) mice. © 2012 Wiley Periodicals, Inc. Photochemistry and Photobiology © 2012 The American Society of Photobiology.
Effects of preoperative oral carbohydrate solution intake on thermoregulation.
Ozer, Ayse B; Demirel, Ismail; Kavak, Burcin S; Gurbuz, Oguz; Unlu, Serap; Bayar, Mustafa K; Erhan, Ömer L
2013-07-31
We aimed to investigate the oral carbohydrate solution administered preoperatively on thermoregulation. The study included 40 female patients under general anesthesia. Patients were randomly divided into 2 groups: Group CONT (stopped oral implementation 8 h before the operation) and Group CHO (800ml oral carbohydrate fluid 8 h before the operation and 400ml oral carbohydrate fluid 2 h before the operation). Patients were monitored as standard and temperature probes were placed. Temperatures were recorded immediately before anesthetics induction, 5 min after the anesthetics induction, and in the post-anesthesia care unit (PACU) every 10 min. Mean skin temperature (Tsk), mean body temperature (Tb), and vasoconstriction threshold were estimated. In general, we observed a decrease in tympanic temperature and Tb following anesthetic administration in groups, and increase in Tsk, and an increase in all 3 of these levels in the recovery unit. Tympanic temperature was significantly higher at 25, 55, 65, and 95 min after induction in Group CONT compared to Group CHO (p<0.05). Tsk was found to be lower in Group CONT compared to Group CHO in almost all periods. In PACU, it was found that the tympanic temperature was higher in Group CONT compared to Group CHO at 60 min (p<0.05). Postoperative shivering score was found to be significantly higher in Group C (p<0.01). Vasoconstriction threshold was higher in Group CONT than Group CHO. Oral carbohydrate solution administered was established to have effects thought to be negative on tympanic temperature, vasoconstriction, and vasoconstriction threshold.
Greiner, Jesse G; Clegg, Miriam E; Walsh, Michael L; White, Matthew D
2010-05-01
Hyperthermia potentiates the influence of CO(2) on pulmonary ventilation (.V(E)). It remains to be resolved how skin and core temperatures contribute to the elevated exercise ventilation response to CO(2). This study was conducted to assess the influences of mean skin temperature (_T(SK)) and end-tidal PCO(2) (P(ET)CO(2)) on .V(E) during submaximal exercise with a normothermic esophageal temperature (T(ES)). Five males and three females who were 1.76 +/- 0.11 m tall (mean +/- SD), 75.8 +/- 15.6 kg in weight and 22.0 +/- 2.2 years of age performed three 1 h exercise trials in a climatic chamber with the relative humidity (RH) held at 31.5 +/- 9.5% and the ambient temperature (T (AMB)) maintained at one of 25, 30, or 35 degrees C. In each trial, the volunteer breathed eucapnic air for 5 min during a rest period and subsequently cycle ergometer exercised at 50 W until T (ES) stabilized at approximately 37.1 +/- 0.4 degrees C. Once T (ES) stabilized in each trial, the volunteer breathed hypercapnic air twice for approximately 5 min with P(ET)CO(2) elevated by approximately +4 or +7.5 mmHg. The significantly (P < 0.05) different increases of P(ET)CO(2) of +4.20 +/- 0.49 and +7.40 +/- 0.51 mmHg gave proportionately larger increases in .V(E) of 10.9 +/- 3.6 and 15.2 +/- 3.6 L min(-1) (P = 0.001). This hypercapnia-induced hyperventilation was uninfluenced by varying the _T(SK) to three significantly different levels (P < 0.001) of 33.2 +/- 1.2 degrees C, to 34.5 +/- 0.8 degrees C to 36.4 +/- 0.5 degrees C. In conclusion, the results support that skin temperature between approximately 33 and approximately 36 degrees C has neither effect on pulmonary ventilation nor on hypercapnia-induced hyperventilation during a light exercise with a normothermic core temperature.
Whole body cooling by immersion in water at moderate temperatures.
Marino, F; Booth, J
1998-06-01
This study investigated the potential use of whole body cooling by water immersion for lowering body temperatures prior to endurance exercise. Rectal temperature (Tre), mean skin temperature (Tsk), oxygen consumption (VO2), and ventilation (VE) were measured in 7 male and 3 female subjects who were immersed in a water bath for up to 60 min. Initial water temperature was 28.8+/-1.5 degrees C and decreased to 23.8+/-1.1 degrees C by the end of immersion. Pre-immersion Tre of 37.34+/-0.36 degrees C was not altered by 60 min water immersion but decreased to 36.64+/-0.34 degrees C at 3 min post immersion (p < 0.01). Tsk decreased from 33.23+/-1.4 degrees C to 26.95+/-1.8 degrees C (p < 0.01) at the end of immersion. Reductions in Tre and Tsk resulted in reduced body heat content (Hc) of approximately 545 kJ (p < 0.01) at the end of immersion. VO2 and VE increased from pre-immersion values of 0.34+/-0.08 L x min(-1) and 6.2+/-1.4 L x min(-1) to 0.54+/-0.09 L x min(-) and 11.5+/-5.4 L x min(-1) at the end of immersion, respectively. Heart rate remained unchanged throughout immersion. These results indicate that whole body immersion in moderately cold water temperatures is an effective cooling maneuver for lowering body temperatures and body Hc in the absence of severe physiological responses generally associated with sudden cold stress.
Prediction of the average skin temperature in warm and hot environments.
Mehnert, P; Malchaire, J; Kampmann, B; Piette, A; Griefahn, B; Gebhardt, H
2000-05-01
The prediction of the mean skin temperature used for the Required Sweat Rate index was criticised for not being valid in conditions with high radiation and high humidity. Based on a large database provided by 9 institutes, 1999 data points obtained using steady-state conditions, from 1399 experiments and involving 377 male subjects, were used for the development of a new prediction model. The observed mean skin temperatures ranged from 30.7 degrees C to 38.6 degrees C. Experimental conditions included air temperatures (Ta) between 20 and 55 degrees C, mean radiant temperatures (Tr) up to 145 degrees C, partial vapour pressures (Pa) from 0.2 to 5.3 kPa, air velocities (v(a)) between 0.1 and 2 m/s, and metabolic rates (M) from 102 to 620 W. Rectal temperature (T(re)) was included in the models to increase the accuracy of prediction. Separate models were derived for nude (clothing insulation, I(cl), < or = 0.2 clo, where 1 clo = 0.155 m2 x degrees C x W(-1), which is equivalent to the thermal insulation of clothing necessary to maintain a resting subject in comfort in a normally ventilated room, air movement = 10 cm/s, at a temperature of 21 degrees C and a humidity of less than 50%) and clothed (0.6 < or = I(cl) < or = 1.0 clo) subjects using a multiple linear regression technique with re-sampling (non-parametric bootstrap). The following expressions were obtained for nude and clothed subjects, respectively: T(sk) = 7.19 + 0.064Ta + 0.061Tr + 0.198Pa - 0.348v(a) + 0.616T(re) and T(sk) = 12.17 + 0.020Ta + 0.044Tr + 0.194Pa - 0.253v(a) + 0.0029M + 0.513T(re). For the nude and clothed subjects, 83.3% and 81.8%, respectively, of the predicted skin temperatures were within the range of +/- 1 degree C of the observed skin temperatures. It is concluded that the proposed models for the prediction of the mean skin temperature are valid for a wide range of warm and hot ambient conditions in steady-state conditions, including those of high radiation and high humidity.
Thermoregulatory responses of rhesus monkeys during spaceflight
NASA Technical Reports Server (NTRS)
Sulzman, F. M.; Ferraro, J. S.; Fuller, C. A.; Moore-Ede, M. C.; Klimovitsky, V.; Magedov, V.; Alpatov, A. M.
1992-01-01
This study examines the activity, axillary temperature (T(ax)), and ankle skin temperature (Tsk) of two male Rhesus monkeys exposed to microgravity in space. The animals were flown on a Soviet biosatellite mission (COSMOS 1514). Measurements on the flight animals, as well as synchronous flight controls, were performed in the Soviet Union. Additional control studies were performed in the United States to examine the possible role of metabolic heat production in the T(ax) response observed during the spaceflight. All monkeys were exposed to a 24-h light-dark cycle (LD 16:8) throughout these studies. During weightlessness, T(ax) in both flight animals was lower than on earth. The largest difference (0.75 degree C) occurred during the night. There was a reduction in mean heart rate and Tsk during flight. This suggests a reduction in both heat loss and metabolic rate during spaceflight. Although the circadian rhythms in all variables were present during flight, some differences were noted. For example, the amplitude of the rhythms in Tsk and activity were attenuated. Furthermore, the T(ax) and activity rhythms did not have precise 24.0 hour periods and may have been externally desynchronized from the 24-h LD cycle. These data suggest a weakening of the coupling between the internal circadian pacemaker and the external LD synchronizer.
O'dell, N L; Burlison, S K; Starcher, B C; Pennington, C B
1996-05-01
The tight-skin (TSK) mouse is characterized by the hyperplasia of loose connective tissues, and of excessive growth of cartilage and of bones including the mandible. Since the fibroelastic connective tissues of the craniomandibular joint (CMJ) are essential to the functions of this joint, the present histological study compared the presence and general distribution of elastic fibres in CMJ discal tissues of TSK and normal mice. The excised CMJs were processed for light microscopy. The tissues were fixed, demineralized, embedded in paraffin, sectioned and then stained with resorcin-fuchsin to demonstrate elastic fibres. There were no obvious histological differences in either the amount or the distribution of elastic fibres in the discs from the two groups. In both groups, elastic fibres were found in the disc and in many of the attachments of the disc to the mandible and squamosal bone. In addition to the morphological preparations, articular discs and samples of lung tissue were excised from other mice and subjected to a radioimmunoassay for desmosine in order to estimate the amounts of elastin in these tissues; the amount of elastin was significantly reduced in the TSK lung, but the amounts of elastin in the TSK and normal CMJ discal tissues were not significantly different statistically. These morphological and histochemical results suggest that the distribution and quantity of elastic fibres in the TSK mouse disc are not significantly different from those in the normal mouse articular disc. Moreover, these data may be interpreted to either suggest a differential effect on the elastic fibres in different TSK tissues, or to support the suggestion that abnormal degradation of elastic fibres may not be characteristic of the TSK mouse.
Garzón-Villalba, Ximena P; Wu, Yougui; Ashley, Candi D; Bernard, Thomas E
2017-07-01
There are times when it is not practical to assess heat stress using environmental metrics and metabolic rate, and heat strain may provide an alternative approach. Heat strain indicators have been used for decades as tools for monitoring physiological responses to work in hot environments. Common indicators of heat strain are body core temperature (assessed here as rectal temperature Tre), heart rate (HR), and average skin temperature (Tsk). Data collected from progressive heat stress trials were used to (1) demonstrate if physiological heat strain indicators (PHSIs) at the upper limit of Sustainable heat stress were below generally accepted limits; (2) suggest values for PHSIs that demonstrate a Sustainable level of heat stress; (3) suggest alternative PHSIs; and (4) determine if metabolic rate was an effect modifier. Two previous progressive heat stress studies included 176 trials with 352 pairs of Sustainable and Unsustainable exposures over a range of relative humidities and metabolic rates using 29 participants. To assess the discrimination ability of PHSIs, conditional logistic regression and stepwise logistic regression were used to find the best combinations of predictors of Unsustainable exposures. The accuracy of the models was assessed using receiver operating characteristic curves. Current recommendations for physiological heat strain limits were associated with probabilities of Unsustainable greater than 0.5. Screening limits for Sustainable heat stress were Tre of 37.5°C, HR of 105 bpm, and Tsk of 35.8°C. Tsk alone resulted in an area under the curve of 0.85 and the combination of Tsk and HR (area under the curve = 0.88) performed the best. The adjustment for metabolic rate was statistically significant for physiological strain index or ∆Tre-sk as main predictors, but its effect modification was negligible and could be ignored. Based on the receiver operating characteristic curve, PHSIs (Tre, HR, and Tsk) can accurately predict Unsustainable heat stress exposures. Tsk alone or in combination with HR has a high sensitivity, and makes better discriminations than the other PHSIs under relatively constant exposure (metabolic rate and environment) for an hour or so. Screening limits with high sensitivity, however, have low thresholds that limit utility. To the extent that the observed strain is low, there is good evidence that the exposure is Sustainable. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Ice Slurry Ingestion Leads to a Lower Net Heat Loss during Exercise in the Heat.
Morris, Nathan B; Coombs, Geoff; Jay, Ollie
2016-01-01
To compare the reductions in evaporative heat loss from the skin (Esk) to internal heat loss (Hfluid) induced by ice slurry (ICE) ingestion relative to 37 °C fluid and the accompanying body temperature and local thermoeffector responses during exercise in warm, dry conditions (33.5 °C ± 1.4 °C; 23.7% ± 2.6% relative humidity [RH]). Nine men cycled at approximately 55% VO2peak for 75 min and ingested 3.2 mL · kg(-1) aliquots of 37 °C fluid or ICE after 15, 30, and 45 min of exercise. Metabolic heat production (M-W), rectal temperature (Tre), mean skin temperature (Tsk), whole-body sweat loss (WBSL), local sweat rate (LSR), and skin blood flow (SkBF) were measured throughout. Net heat loss (HLnet) and heat storage (S) were estimated using partitional calorimetry. Relative to the 37 °C trial, M-W was similar (P = 0.81) with ICE ingestion; however, the 200 ± 20 kJ greater Hfluid (P < 0.001) with ICE ingestion was overcompensated by a 381 ± 199-kJ lower Esk (P < 0.001). Net heat loss (HLnet) was consequently 131 ± 120 kJ lower (P = 0.01) and S was greater (P = 0.05) with ICE ingestion compared with 37 °C fluid ingestion. Concurrently, LSR and WBSL were lower by 0.16 ± 0.14 mg · min(-1) · cm(-2) (P < 0.01) and 191 ± 122 g (P < 0.001), respectively, and SkBF tended to be lower (P = 0.06) by 5.4%maxAU ± 13.4%maxAU in the ICE trial. Changes in Tre and Tsk were similar throughout exercise with ICE compared to 37 °C fluid ingestion. Relative to 37 °C, ICE ingestion caused disproportionately greater reductions in Esk relative to Hfluid, resulting in a lower HLnet and greater S. Mechanistically, LSR and possibly SkBF were suppressed independently of Tre or Tsk, reaffirming the concept of human abdominal thermoreception. From a heat balance perspective, recommendations for ICE ingestion during exercise in warm, dry conditions should be reconsidered.
NASA Astrophysics Data System (ADS)
Okamoto-Mizuno, Kazue; Tsuzuki, Kazuyo; Mizuno, Koh
2005-03-01
This study sought to investigate the effects of humid heat exposure in later sleep segments on sleep stages and body temperature in humans. The subjects were eight healthy males, from whom informed consent had been obtained. The experiments were carried out under three different sets of conditions: a control climate [air temperature (Ta)=26°C, relative humidity (RH)=50%] (C); a humid heat climate (Ta=32°C, RH=80%) (H); and a humid heat exposure in later sleep segments (C for the first 3 h 45 min, followed by a 30-min transition to H, which was then maintained for the last 3 h 45 min) (C H). Electroencephalogram, EOG, and mental electromyogram, rectal temperature (Tre), and skin temperature (Tsk) were continuously measured. The total amount of wakefulness was significantly increased in H compared to C H or C. Compared to C, wakefulness in C H and H was significantly increased during later sleep segments. Tre and mean Tsk were significantly higher in H than in C H or C. In C H, Tsk and Tre increased to levels equal to those observed in H after Ta and RH increase. Whole body sweat loss was significantly lower in C H and C than in H. These results suggest that humid heat exposure in the later sleep segment reduces thermal load as compared to full-night humid heat exposure. In daily life, the use of air conditioning in the initial sleep hours can protect sleep and thermoregulation.
Effects of exercise in the heat on thermoregulation of Japanese and Malaysian males.
Saat, Mohamed; Tochihara, Yutaka; Hashiguchi, Nobuko; Sirisinghe, Roland Gamini; Fujita, Mizuho; Chou, Chin Mei
2005-07-01
The effect of low-intensity exercise in the heat on thermoregulation and certain biochemical changes in temperate and tropical subjects under poorly and well-hydrated states was examined. Two VO2max matched groups of subjects consisting of 8 Japanese (JS) and 8 Malaysians (MS) participated in this study under two conditions: poorly-hydrated (no water was given) and well-hydrated (3 mL x Kg(-1) body weight of water was provided at onset of exercise, and the 15th, 35th and 55th min of exercise). The experimental room in both countries was adjusted to a constant level (Ta: 31.6+/-0.03 degrees C, rh: 72.3+/-0.13%). Subjects spent an initial 10 min rest, 60 min of cycling at 40% VO2max and then 40 min recovery in the experimental room. Rectal temperatures (Tre) skin temperatures (Tsk), heart rate (HR), heat-activated sweat glands density (HASG), local sweat rate (M sw-back) and percent dehydration were recorded during the test. Blood samples were analysed for plasma glucose and lactate levels.The extent of dehydration was significantly higher in the combined groups of JS (1.43+/-0.08%) compared to MS (1.15+/-0.05%). During exercise M sw-back was significantly higher in JS compared to MS in the well-hydrated condition. The HASG was significantly more in JS compared to MS at rest and recovery. Tre was higher in MS during the test. Tsk was significantly higher starting at the 5th min of exercise until the end of the recovery period in MS compared to JS. In conclusion, tropical natives have lower M sw-back associated with higher Tsk and Tre during the rest, exercise and recovery periods. However, temperate natives have higher M sw-back and lower Tsk and Tre during experiments in a hot environment. This phenomenon occurs in both poorly-hydrated and well-hydrated states with low intensity exercise. The differences in M sw-back, Tsk and Tre are probably due to a setting of the core temperature at a higher level and enhancement of dry heat loss, which occurred during passive heat exposure.
Time required to stabilize thermographic images at rest
NASA Astrophysics Data System (ADS)
Marins, João Carlos Bouzas; Moreira, Danilo Gomes; Cano, Sergio Piñonosa; Quintana, Manuel Sillero; Soares, Danusa Dias; Fernandes, Alex de Andrade; Silva, Fabrício Sousa da; Costa, Carlos Magno Amaral; Amorim, Paulo Roberto dos Santos
2014-07-01
Thermography for scientific research and practical purposes requires a series of procedures to obtain images that should be standardized; one of the most important is the time required for acclimatization in the controlled environment. Thus, the objective of this study was to identify the appropriate acclimatization time in rest to reach a thermal balance on young people skin. Forty-four subjects participated in the study, 18 men (22.3 ± 3.1 years) and 26 women (21.7 ± 2.5 years). Thermographic images were collected using a thermal imager (Fluke®), totaling 44 images over a period of 20 min. The skin temperature (TSK) was measured at the point of examination which included the 0 min, 2, 4, 6, 8, 10, 12, 14, 16, 18 and 20. The body regions of interest (ROI) analyzed included the hands, forearms, arms, thighs, legs, chest and abdomen. We used the Friedman test with post hoc Dunn's in order to establish the time at rest required to obtain a TSK balance and the Mann-Whitney test was used to compare age, BMI, body fat percentage and temperature variations between men and women, considering always a significance level of p < 0.05. Results showed that women had significantly higher temperature variations than men (p < 0.01) along the time. In men, only the body region of the abdomen obtained a significant variance (p < 0.05) on the analyzed period, both in the anterior and posterior part. In women, the anterior abdomen and thighs, and the posterior part of the hands, forearms and abdomen showed significant differences (p < 0.05). Based on our results, it can be concluded that the time in rest condition required reaching a TSK balance in young men and women is variable, but for whole body analysis it is recommended at least 10 min for both sexes.
Physiological and subjective responses to standing showers, sitting showers, and sink baths.
Ohnaka, T; Tochihara, Y; Kubo, M; Yamaguchi, C
1995-09-01
The purpose of this study was to investigate physiological and subjective responses during and after bathing in three different bathing methods. Eight healthy males bathed for 10 minutes, and then rested for 30 minutes. Three kinds of bathing methods - standing shower, sitting shower and sink bath - were adopted in this experiment. Water temperature and flow volume of the showers were kept at 41 degrees C and 11 liter/min, while water temperature of the bath was kept at 40 degrees C. Rectal temperature, skin temperatures and heart rate of the subjects were measured continuously during bathing and the subsequent 30-minute rest. Blood pressure and votes for thermal sensations were recorded before bathing, after 5 and 10 minutes of bathing, and 5, 10, 20 and 30 minutes after bathing. The following results were obtained. 1) Although rectal temperature rose, on the average, by 0.15 degrees C in all bathing methods, there were no significant differences among the three bathing methods at any time in the experiment. 2) Mean skin temperature (Tsk) during the sink bath was significantly higher than that in the standing or sitting shower. After bathing, Tsk of sink bath was slightly higher than those of the remaining conditions, but did not significantly differ among the bathing methods. 3) Heart rate increased gradually during all the bathing methods, however, only HR in the standing shower exceeded 100 beats/min which was significantly higher than those of the two remaining bathing methods. 4) Blood pressure (BP) decreased rapidly during the sink bath in contrast to an increased BP in the sitting and standing showers.
Superficial shell insulation in resting and exercising men in cold water.
Veicsteinas, A; Ferretti, G; Rennie, D W
1982-06-01
From measurements of subcutaneous fat temperature (Tsf) at known depths below the surface, skin surface temperature (Tsk), and direct skin heat flux (H), the superficial shell isulation (Iss) of the thigh (fat + skin) was calculated as Iss (degrees C.m2.w-1) = (Tsf - Tsk)/H in nine male subjects immersed head out in a well-stirred water bath. Also, at critical water temperature (CWT = 28-33 degrees C), eight of the subjects rested for 3 h, enabling overall maximal tissue insulation (It,max) to be calculated as It,max (degrees C.m2.W-1) = (Tre - Tw)/(0.92 M +/- delta S), where Tre is rectal temperature, Tw is water temperature, M is metabolic rate, and s is loss or gain of body heat. Five subjects performed up to 2 h of mild leg cycling, preceded and followed by 60 min of rest, and both thigh Iss and overall It were measured during exercise. Iss increased from minimal values in Tw greater than 33 degrees C to maximal values (Iss,max) at CWT or below. Iss,max was linearly related to tissue thickness (d) in millimeters of fat plus skin, Iss,max (degrees C.m2.W-1) = 0.0048d-0.0052; r = 0.95, n = 37, and was not influenced by leg exercise up to a metabolic rate of 150 W.m-2 in CWT despite large increases in Tsf and H and large decreases in overall It. The slope of Iss,max vs. depth, 0.0048 degrees C.m2.W-1.mm-1, is almost identical to thermal resistivity of fat in vitro, suggesting that the superficial shell is unperfused in CWT at rest or during mild exercise. When maximal superficial shell insulation (It,ss,max) for the whole body was calculated with allowance for differing fat thicknesses and surface areas of body regions, it could account for only 10-15% of overall It,max at rest and 35-40% of overall It in mild exercise. We suggest that the poorly perfused muscle shell plays a more important role as a defense against cooling at CWT than does the superficial shell (fat + skin), particularly at rest.
Filingeri, D; Fournet, D; Hodder, S; Havenith, G
2015-06-01
We investigated the effects of mild evaporative cooling applied to the torso, before or during running in the heat. Nine male participants performed three trials: control-no cooling (CTR), pre-exercise cooling (PRE-COOL), and during-exercise cooling (COOL). Trials consisted of 10-min neutral exposure and 50-min heat exposure (30 °C; 44% humidity), during which a 30-min running protocol (70% VO2max ) was performed. An evaporative cooling t-shirt was worn before the heat exposure (PRE-COOL) or 15 min after the exercise was started (COOL). PRE-COOL significantly lowered local skin temperature (Tsk ) (up to -5.3 ± 0.3 °C) (P < 0.001), mean Tsk (up to -2 ± 0.1 °C) (P < 0.001), sweat losses (-143 ± 40 g) (P = 0.002), and improved thermal comfort (P = 0.001). COOL suddenly lowered local Tsk (up to -3.8 ± 0.2 °C) (P < 0.001), mean Tsk (up to -1 ± 0.1 °C) (P < 0.001), heart rate (up to -11 ± 2 bpm) (P = 0.03), perceived exertion (P = 0.001), and improved thermal comfort (P = 0.001). We conclude that the mild evaporative cooling provided significant thermoregulatory benefits during exercise in the heat. However, the timing of application was critical in inducing different thermoregulatory responses. These findings provide novel insights on the thermoregulatory role of Tsk during exercise in the heat. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Wind speed limits to work under hot environments for clothed men.
Kamon, E; Avellini, B
1979-02-01
Four heat-acclimated clothed young adult men exercised (treadmill) at metabolic rate of 191 W.m-2 (27% VO2 max), under five air temperatures (Ta) between 36 and 53 degrees C and three wind velocities (v), 1, 2, and 4 m.s-1, for 2 h. The 2nd h of each experiment involved progressive increases in the ambient vapor pressure (Pa) to force an upward inflection of the rectal temperature (Tre). The Tre point of inflection identified the critical Pa (Pcrit) for each Ta. The average mean skin temperature (Tsk = 36 degrees C for all Pcrit. Straight-line isotherms for Tsk = 36 degrees C, which agreed with the negative regressions of the Pcrit on Ta, represented the limits of exposure for Ta less than or equal to 44 degrees C. The slope characteristics of the isotherms corresponded with skin wettedness (w) of 0.94, 0.71, and 0.58, respectively, for v of 1, 2, and 4 m.s-1. For Ta greater than 44 degrees C the limit line corresponded with steeper negative regressions indicating a lower w than for Ta less than or equal to 44 degrees C. Despite the increase in the ambient evaporative capacity due to the higher v the limit lines describing exposure limits were not significantly different either at Ta less than or equal to 44 degrees C for v of 2 and 4 m.s-1 or at Ta greater than 44 degrees C for all three v.
Exercise thermoregulation in men after 1 and 24-hours of 6 degrees head-down tilt
NASA Technical Reports Server (NTRS)
Ertl, A. C.; Dearborn, A. S.; Weidhofer, A. R.; Bernauer, E. M.; Greenleaf, J. E.
2000-01-01
BACKGROUND: Exercise thermoregulation is dependent on heat loss by increased skin blood flow (convective and conductive heat loss) and through enhanced sweating (evaporative heat loss). Reduction of plasma volume (PV), increased plasma osmolality, physical deconditioning, and duration of exposure to simulated and actual microgravity reduces the ability to thermoregulate during exercise. HYPOTHESIS: We hypothesized that 24 h of head down tilt (HDT24) would alter thermoregulatory responses to a submaximal exercise test and result in a higher exercise rectal temperature (Tre) when compared with exercise Tre after 1 h of head down tilt (HDT1). METHODS: Seven men (31+/-SD 6 yr, peak oxygen uptake (VpO2peak) of 44+/-6 ml x kg(-1) x min(-1)) were studied during 70 min of supine cycling at 58+/-SE 1.5% VO2peak at 22.0 degrees C Tdb and 47% rh. RESULTS: Relative to pre-tilt sitting chair rest data, HDT1 resulted in a 6.1+/-0.9% increase and HDT24 in a 4.3+/-2.3% decrease in PV (delta = 10.4% between experiments, p<0.05) while plasma osmolality remained unchanged (NS). Pre-exercise Tre was elevated after HDT24 (36.71 degrees C +/-0.06 HDT1 vs. 36.93 degrees C+/-0.11 HDT24, p<0.05). The 70 min of exercise did not alter this relationship (p<0.05) with respective end exercise increases in Tre to 38.01 degrees C and 38.26 degrees C (degrees = 1.30 degrees C (HDT1) and 1.33 degrees C (HDT24)). While there were no pre-exercise differences in mean skin temperature (Tsk), a significant (p<0.05) time x treatment interaction occurred during exercise: after min 30 in HDT24 the Tsk leveled off at 31.1 degrees C, while it continued to increase reaching 31.5 degrees C at min 70 in HDT1. A similar response (NS) occurred in skin blood velocity. Neither local sweating rates nor changes in body weight during exercise of -1.63+/-0.24 kg (HDT1) or - 1.33+/-0.09 kg (HDT24) were different (NS) between experiments. CONCLUSION: While HDT24 resulted in elevated pre-exercise Tre, reduced PV, attenuation of Tsk and skin blood velocity during exercise, the absolute increase in exercise Tre was not altered. But if sweat rate and cutaneous vascular responses were similar at different core temperatures (unchanged thermoregulation), the Tre offset could have been caused by the HDT-induced hypovolemia.
Evaluation of three commercial microclimate cooling systems
NASA Astrophysics Data System (ADS)
Cadarette, Bruce S.; Decristofano, Barry S.; Speckman, Karen N.; Sawka, Michael N.
1988-11-01
Three commercially available microclimate cooling systems were evaluated for their ability to reduce heat stress in men exercising in a hot environment while wearing high insulative, low permeability clothing. The cooling systems were: (1) ILC Dover Model 19 Coolvest (ILC) (2) LSSI Coolhead(LSSI), and (3) Thermacor Cooling vest (THERM). Endurance Time (ET), Heart Rate (HR), rectal temperature (Tre), mean skin temperature (TSK), Sweating Rate (SR), Rated Perceived Exertion (RPE) and Thermal Sensation (TS) were measured. The subjects self-terminated on all LSSI tests because of headaches. Statistical analyses were performed on data collected at 60 minutes to have values on all subjects. There were no differences in HR, Tre, SR or TS values among the cooling vests. The subjects' TSK was lower (P less than 0.05) for the LSSI than THERM: and RPE values were higher (P less than 0.05) for LSSI than the other two vests. These data suggest an improved physiological response to exercise heat stress with all three commercial systems with the greatest benefit in performance time provided by the ILC cooling system.
Wilson, Thad E; Carter, Robert; Cutler, Michael J; Cui, Jian; Smith, Michael L; Crandall, Craig G
2004-02-01
The purpose of this study was to identify whether baroreceptor unloading was responsible for less efficient heat loss responses (i.e., skin blood flow and sweat rate) previously reported during inactive compared with active recovery after upright cycle exercise (Carter R III, Wilson TE, Watenpaugh DE, Smith ML, and Crandall CG. J Appl Physiol 93: 1918-1929, 2002). Eight healthy adults performed two 15-min bouts of supine cycle exercise followed by inactive or active (no-load pedaling) supine recovery. Core temperature (T(core)), mean skin temperature (T(sk)), heart rate, mean arterial blood pressure (MAP), thoracic impedance, central venous pressure (n = 4), cutaneous vascular conductance (CVC; laser-Doppler flux/MAP expressed as percentage of maximal vasodilation), and sweat rate were measured throughout exercise and during 5 min of recovery. Exercise bouts were similar in power output, heart rate, T(core), and T(sk). Baroreceptor loading and thermal status were similar during trials because MAP (90 +/- 4, 88 +/- 4 mmHg), thoracic impedance (29 +/- 1, 28 +/- 2 Omega), central venous pressure (5 +/- 1, 4 +/- 1 mmHg), T(core) (37.5 +/- 0.1, 37.5 +/- 0.1 degrees C), and T(sk) (34.1 +/- 0.3, 34.2 +/- 0.2 degrees C) were not significantly different at 3 min of recovery between active and inactive recoveries, respectively; all P > 0.05. At 3 min of recovery, chest CVC was not significantly different between active (25 +/- 6% of maximum) and inactive (28 +/- 6% of maximum; P > 0.05) recovery. In contrast, at this time point, chest sweat rate was higher during active (0.45 +/- 0.16 mg.cm(-2).min(-1)) compared with inactive (0.34 +/- 0.19 mg.cm(-2).min(-1); P < 0.05) recovery. After exercise CVC and sweat rate are differentially controlled, with CVC being primarily influenced by baroreceptor loading status while sweat rate is influenced by other factors.
Kakitsuba, Naoshi; Mekjavic, Igor B; Katsuura, Tetsuo
2009-11-01
For evaluating the effect of body physique, somatotype, and physical constitution on individual variability in the core interthreshold zone (CIZ), data from 22 healthy young Japanese male subjects were examined. The experiment was carried out in a climatic chamber in which air temperature was maintained at 20-24 degrees C. The subjects' body physique and the maximum work load were measured. Somatotype was predicted from the Heath-Carter Somatotype method. In addition, factors reflecting physical constitution, for example, susceptibility to heat and cold, and quality of sleep were obtained by questionnaire. The subjects wore a water-perfused suit which was perfused with water at a temperature of 25 degrees C and at a rate of 600 cc/min, and exercised on an ergometer at 50% of their maximum work rate for 10-15 min until their sweating rate increased. They then remained continuously seated without exercise until shivering increased. Rectal temperature (T(re)) and skin temperatures at four sites were monitored by thermistors, and sweating rate was measured at the forehead with a sweat rate monitor. Oxygen uptake was monitored with a gas analyzer. The results showed individual variability in the CIZ. According to the reciprocal cross-inhibition (RCI) theory, thermoafferent information from peripheral and core sensors is activated by T(re), mean skin temperature (T(sk)), and their changes. Since T(sk) was relatively unchanged, the data were selected to eliminate the influence of the core cooling rate on the sensor-to-effector pathway before RCI, and the relationship between the CIZ and the various factors was then analyzed. The results revealed that susceptibility to heat showed a good correlation with the CIZ, indicating that individual awareness of heat may change the CIZ due to thermoregulatory behavior.
Thermal and metabolic responses of military divers during a 6-hour static dive in cold water.
Riera, Florence; Horr, Reed; Xu, Xiaojiang; Melin, Bruno; Regnard, Jacques; Bourdon, Lionel
2014-05-01
Human thermal responses during prolonged whole-body immersion in cold water are of interest for the military, especially French SEALS. This study aims at describing the thermo-physiological responses. There were 10 male military divers who were randomly assigned to a full immersion in neutral (34 degrees C), moderately cold (18 degrees C), and cold (10 degrees C) water wearing their operational protective devices (5.5 mm wetsuit with 3.0 mm thick underwear) for 6 h in a static position. Rectal temperature (T(re)) and 14 skin temperatures (T(sk)), blood analysis (stress biomarkers, metabolic substrates), and oxygen consumption (Vo2) were collected. At 34 degrees C, there were no significant modifications of the thermo-physiological responses over time. The most interesting result was that rates of rectal temperature decrease (0.15 +/- 0.02 degrees C x min(-1)) were the same between the two cold stress experimental conditions (at 18 degrees C and 10 degrees C). At the final experiment, rectal temperature was not significantly different between the two cold stress experimental conditions. Mean T(sk) decreased significantly during the first 3 h of immersion and then stabilized at a lower level at 10 degrees C (25.6 +/- 0.8 degrees C) than at 18 degrees C (29.3 +/- 0.9 degrees C). Other results demonstrate that the well-trained subjects developed effective physiological reactions. However, these reactions are consistently too low to counterbalance the heat losses induced by cold temperature conditions and long-duration immersion. This study shows that providing divers with thermal protection is efficient for a long-duration immersion from a medical point of view, but not from an operational one when skin extremities were taken into account.
Thermal comfort zone of the hands, feet and head in males and females.
Ciuha, Urša; Mekjavic, Igor B
2017-10-01
The present study compared the thermal comfort zones (TCZ) of the hands, feet and head in eight male and eight female participants, assessed with water-perfused segments (WPS). On separate occasions, and separated by a minimum of one day, participants were requested to regulate the temperature of three distal skin regions (hands, feet and head) within their TCZ. On each occasion they donned a specific water-perfused segment (WPS), either gloves, socks or hood for assessing the TCZ of the hands, feet and head, respectively. In the absence of regulation, the temperature of the water perfusing the WPS changed in a saw-tooth manner from 10 to 50°C; by depressing a switch and reversing the direction of the temperature at the limits of the TCZ, each participant defined the TCZ for each skin region investigated. The range of regulated temperatures (upper and lower limits of the TCZ) did not differ between studied skin regions or between genders. Participants however maintained higher head (35.7±0.4°C; p˂0.001) skin temperature (Tsk) compared to hands (34.5±0.8°C) and feet (33.8±1.1°C). When exposed to normothermic conditions, distal skin regions do not differ in ranges of temperatures, perceived as thermally comfortable. Copyright © 2017. Published by Elsevier Inc.
Fluid-electrolyte shifts and thermoregulation: Rest and work in heat with head cooling.
Greenleaf, J E; Van Beaumont, W; Brock, P J; Montgomery, L D; Morse, J T; Shvartz, E; Kravik, S
1980-08-01
Plasma volume and thermoregulatory responses were measured, during head and neck cooling with a liquid-cooled neoprene headgear, in four men (21-43 years old) during 60 min of rest, 60 min of ergometer exercise (45% VO2 max), and 30 min of recovery in the supine position at 40.1 degrees C DBT and 40% rh. Compared with control (noncooling) responses, cooling decreased thigh sweating and increased mean skin temperature (Tsk) at rest, and attenuated the increases in thigh sweating by 0.26 mg/min x cm2 (-22.4%, p < 0.05), heart rate by 10 b/min (-8.5%, N.S.), rectal temperature (Tre) by 0.3 degrees C (N.S.), and ventilation by 12.5% (N.S.) during exercise. In recovery, cooling facilitated the decreases in thigh sweat rate, heart rate, Tre, and forearm blood flow, and enhanced the increase in Tsk toward control levels. Cooling had no effect upon plasma protein, osmotic, or electrolyte shifts during rest, exercise, or recovery. Plasma volume (PV) loss during exercise was 11.2% without cooling and 10.9% with cooling. Cooling increased PV by 3% (p < 0.05) during rest, and this differential was maintained throughout the exercise and recovery periods.
Are All Heat Loads Created Equal?
Meade, Robert D; Kenny, Glen P
2017-09-01
We evaluated physiological responses during exercise at a fixed evaporative requirement for heat balance (Ereq) but varying combinations of metabolic and environmental heat load. Nine healthy, physically active males (age: 46 ± 8 yr) performed four experimental sessions consisting of 75 min of semirecumbent cycling at various ambient temperatures. Whole-body dry heat loss (direct calorimetry) was monitored continuously as was heat production (indirect calorimetry), which was adjusted to achieve an Ereq of 400 W. The resultant metabolic heat productions and ambient temperatures for the sessions were as follows: (i) 440 W and 30°C (440 [30]), (ii) 388 W and 35°C (388 [35]), (iii) 317 W and 40°C (317 [40]), and (iv) 258 W and 45°C (258 [45]). Whole-body evaporative heat loss was determined via direct calorimetry. Esophageal (Tes) and mean skin (Tsk) temperatures as well as HR were monitored continuously. Mean body temperature (Tb) was calculated from Tes and Tsk. Physiological strain index (PSI) was determined from Tes and HR. End-exercise evaporative heat loss and Tb were similar between conditions (both P ≥ 0.48). Tes was greater in 440 [30] (37.67°C ± 0.04°C) and 388 [35] (37.58°C ± 0.07°C) relative to both 317 [40] (37.35°C ± 0.06°C) and 258 [45] (37.20°C ± 0.07°C; all P ≤ 0.05). Further, Tsk was different between each condition (440 [30], 33.85°C ± 0.16°C; 388 [35], 34.53°C ± 0.08°C; 317 [40], 35.67°C ± 0.07°C; and 258 [45], 36.54°C ± 0.08°C; all P < 0.01). In 440 [30], HR was elevated by about 13 and 18 bpm relative to 317 [40] and 258 [45], respectively (both P < 0.01). Finally, PSI was greater in both 440 [30] and 388 [35] compared with 317 [40] and 258 [45] (all P ≤ 0.04). Exercise at a fixed Ereq resulted in similar evaporative heat loss and Tb. However, the Tes, Tsk, HR, and PSI responses varied depending on the relative contribution of metabolic and environmental heat load.
Demachi, K; Yoshida, T; Kume, M; Tsuneoka, H
2012-07-01
To assess the effects of starting or stopping leg cooling on the thermoregulatory responses during exercise, 60 min of cycling exercise at 30% of maximal oxygen uptake was performed under 4 conditions using tube trouser perfused with water at 10 °C; no leg cooling (NC), starting of leg cooling after 30 min of exercise (delayed cooling, DC), continuous leg cooling (CC), and stopping of continuous leg cooling after 30 min of exercise (SC) at an environmental temperature of 28.5 °C. During exercise under the DC conditions, an instantaneous increase in the esophageal temperature (Tes), a suppression of the cutaneous vascular conductance at the forearm (%CVC), and a decrease in the mean skin temperature (Tsk) were observed after leg cooling. The total sweat loss (Δm sw,tot) was lower under the DC than the NC condition. In the SC study, however, the Tes remained constant, while the %CVC increased gradually after leg cooling was stopped, and the Δm sw,tot was greater than that under the CC condition. These results suggest that during exercise, rapid skin cooling of the leg may cause an increase in core temperature, while also enhancing thermal stress. However, stopping skin cooling did not significantly affect the core temperature long-term, because the skin blood flow and sweat rate subsequently increased. © Georg Thieme Verlag KG Stuttgart · New York.
Stanhewicz, Anna E; Alexander, Lacy M; Kenney, W Larry
2013-10-01
Reflex vasoconstriction is attenuated in aged skin due to a functional loss of adrenergic vasoconstriction. Bioavailability of tetrahydrobiopterin (BH4), an essential cofactor for catecholamine synthesis, is reduced with aging. Locally administered BH4 increases vasoconstriction through adrenergic mechanisms in aged human skin. We hypothesized that oral sapropterin (Kuvan, a pharmaceutical BH4) would augment vasoconstriction elicited by whole-body cooling and tyramine perfusion in aged skin. Ten healthy subjects (age 75 ± 2 yr) ingested sapropterin (10 mg/kg) or placebo in a randomized, double-blind crossover design. Venous blood samples were collected prior to, and 3 h following ingestion. Three intradermal microdialysis fibers were placed in the forearm skin for local delivery of 1) lactated Ringer, 2) 5 mM BH4, and 3) 5 mM yohimbine + 1 mM propranolol (Y+P; to inhibit adrenergic vasoconstriction). Red cell flux was measured at each site by laser-Doppler flowmetry (LDF) as reflex vasoconstriction was induced by lowering and then clamping whole-body skin temperature (Tsk) using a water-perfused suit. Following whole-body cooling, subjects were rewarmed and 1 mM tyramine was perfused at each site to elicit endogenous norepinephrine release from the perivascular nerve terminal. Cutaneous vascular conductance was calculated as CVC = LDF/mean arterial pressure and expressed as change from baseline (ΔCVC). Plasma BH4 was elevated 3 h after ingestion of sapropterin (43.8 ± 3 vs. 19.1 ± 2 pmol/ml; P < 0.001). Sapropterin increased reflex vasoconstriction at the Ringer site at Tsk ≤ 32.5°C (P < 0.05). Local BH4 perfusion augmented reflex vasoconstriction at Tsk ≤ 31.5°C with placebo treatment only (P < 0.05). There was no treatment effect on reflex vasoconstriction at the BH4-perfused or Y+P-perfused sites. Sapropterin increased pharmacologically induced vasoconstriction at the Ringer site (-0.19 ± 0.03 vs. -0.08 ± 0.02 ΔCVC; P = 0.01). There was no difference in pharmacologically induced vasoconstriction between treatments at the BH4-perfused site (-0.16 ± 0.04 vs. -0.14 ± 0.03 ΔCVC; P = 0.60) or the Y+P-perfused site (-0.05 ± 0.02 vs.-0.06 ± 0.02 ΔCVC; P = 0.79). Sapropterin increases both reflex (cold-induced) and pharmacologically induced vasoconstriction through adrenergic mechanisms and may be a viable intervention to improve reflex vasoconstriction in aged humans.
Rivas, Eric; Newmire, Dan E; Ben-Ezra, Vic
2016-10-15
The objective of this study was to test the hypothesis that a hyperthermia-hypotensive challenge via whole body hot water immersion would alter the perception of hyperthermia and physiological strain in obese type 2 diabetics (T2DM) compared to healthy non-obese (HC) individuals. Additionally, we hypothesize that the mechanisms would be attributed to impaired blood pressure adjustments and afferent signals (via changes in internal and mean skin temperatures). In random order, eleven obese T2DM (50±12y, 45±7% fat mass, 7.5±1.8% HbA1c) and nine similar aged (41±14y, P>0.05) HC non-obese (33±8% fat mass, P<0.01) non-diabetic (5.3±0.4% HbA1c, P<0.01) underwent a 60min bout of whole body passive hyperthermia followed by 60min of recovery or a 2h resting control condition. The perception of thermal sensation (TS, scale range: 1-13), calculated physiological strain (PSI), internal (Tre, rectal) and mean skin (Tsk) temperatures, heart rate (HR) and blood pressures (BP) were the primary dependent variables. Hyperthermia similarly increased Tre by 1.4±0.4°C, Tsk by 6.5±0.8°C and HR by 34±8bpm in both groups (P>0.5). Hyperthermia reduced diastolic BP (27% in T2DM and 33% in HC, P<0.05) and mean arterial BP (reduced by 15% in T2DM and by 19% in HC) relative to control conditions (P<0.05). The reduction of mean arterial BP area under the curve was attenuated in T2DM (12%) compared to HC (30%) (group×condition, P<0.01). TS and PSI during hyperthermia were not different between groups. Pearson product correlation reported strong correlations (r=0.69-0.89) with Tre and Tsk with TS in both populations. The linear stepwise regression analysis revealed similar relative contributions for Tre (~60%) and Tsk (~40%) on TS for both groups. These data indicate that obese T2DM with moderate metabolic control have an attenuated hyperthermia-hypotensive response that does not affect TS and PSI. This also may suggest behavioral thermoregulation is intact in this study group. Copyright © 2016 Elsevier Inc. All rights reserved.
Physical performance and peak aerobic power at different body temperatures.
Bergh, U; Ekblom, B
1979-05-01
In eight male subjects we studied the effect of different core (esophageal, (Tes 34.9--38.4 degrees C) and muscle (Tm 35.1--39.3 degrees C) temperature on 1) physical performance (time to exhaustion at a standard maximal rate of work, WT), 2) aerobic power (VO2), 3) heart rate (HR), and 4) blood lactate (LA) concentration during exhaustive combined arm and leg exercise. In three subjects the effects at different mean skin temperatures (Tsk 27 and 31 degrees C, respectively) were also studied. Peak VO2 was positively correlated to both Tes (r = 0.88) and Tm (r = 0.91). None of the subjects attained control VO2max at Tes and Tm lower than 37.5 and 38.0 degrees C, respectively. HR was correlated to both Tes (r = 0.97) and Tm (r = 0.95). Different Tsk did not affect peak VO2 and HR at subnormal body temperatures. Pulmonary ventilation was independent of Tes and Tm in all experimental situations. LA was significantly higher at Tes 37.5 degrees C compared to both Tes 34.9 and 38.5 degrees C, respectively. At Tes less than 37.5 degrees C and Tm less than 38.0 degrees C, there was a linear reduction in WT (20%.degrees C-1), peak VO2 (5--6%.degrees C-1), and HR (8 beats.min-1.degrees C-1) with lowered Tes and Tm.
Extracerebral deep-body cold sensitivity in the Pekin duck.
Inomoto, T; Simon, E
1981-09-01
Pekin ducks, in which cerebral cold sensitivity is negligible, were submitted to general body cooling at warm, thermoneutral, and cold ambient temperature (Ta) with an intestinal thermode. In some animals, hypothermia was enhanced by additional hypothalamic cooling that suppressed cold defense. In other animals, the spinal cord was cooled, either selectively or during intestinal cooling. From core temperature (Tc) and metabolic heat production (M) an overall cold sensitivity of about -5 to -6 W . kg-1 . degrees C-1 was determined at thermoneutrality. Maximum M amounted to four to five times the resting M of 3.8 W . kg-1 and was attained when Tc fell by 2.5 degrees C or more. In the cold, threshold Tc for the activation of M was elevated; overall cold sensitivity remained constant. In the warmth, threshold Tc was lowered; overall cold sensitivity was reduced, if mean skin temperature (Tsk) remained at aout 39 degrees C or higher. Spinal cold sensitivity amounted to about -0.25 W . kg-1 . degrees C-1 at normal Tc and thermoneutral and warm Ta; it increased to aout -0.50 W . kg-1 . degrees C-1 in the cold and during hypothermia. Peripheral cold sensitivity was estimated from Tsk and M as -0.4 to -0.8 W . kg-1 . degrees C-1. It is concluded that overall cold sensitivity in ducks mainly depends on deep-body temperature sensors outside of the central nervous system.
The effect of 30% nitrous oxide on thermoregulatory responses in humans during hypothermia.
Passias, T C; Mekjavić, I B; Eiken, O
1992-04-01
Clinical studies have reported that body core temperature decreases during prolonged surgery and anesthesia. Although this finding has been attributed primarily to increased heat loss resulting from exposure of body cavities and infusion of cold solutions, it is generally recognized that anesthesia interferes with the thermoregulatory system. The present study examined the effects of mild narcosis induced by 30% N2O on shivering thermogenesis and cutaneous thermoregulatory vasoconstriction in humans, during exposure in a much more intense peripheral thermal stimulus than the ones often used in clinical studies. Nine male subjects were immersed in 15 degrees C water on two separate occasions. During one occasion subjects inspired air (control condition), and during the other occasion the inspired gas mixture contained 20% O2, 30% N2O, and 50% N2 (N2O condition). On both occasions, subjects were immersed to the neck for 60 min, or until their core temperature decreased by 2 degrees C from the preimmersion value. Following the cooling phase, subjects rewarmed via endogenous thermogenesis while lying in a well-insulated bed for 48 min. In the N2O condition, subjects continued to inspire the anesthetic gas mixture during the 48-min period of recovery. O2 uptake (VO2), esophageal temperature (Tes), mean skin temperature (Tsk), mean heat flux (Q) and forearm-fingertip temperature gradient (Tsk-gr) were recorded at 1-min intervals. Tsk and Q in both conditions stabilized within 10 and 25 min of immersion, respectively, and were not significantly different between the two conditions. The cooling rate of Tes was greater during the N2O than the control condition. VO2 increased during the immersion in both conditions and was greater in the control than in the N2O condition. In both conditions, VO2 increased linearly with decreasing Tes, but at any given Tes, VO2 was higher in the control than in the N2O condition. No significant difference was observed in cutaneous thermoregulatory vasoconstriction between the two experimental conditions, as indicated by the Tsk-gr values. The estimated Tes threshold for shivering (estimated from the O2 consumption vs. delta Tes regression) was reduced by 0.95 +/- 0.26 (SE) degrees C during the immersion phase and by 0.39 +/- 0.05 (SE) degrees C during the rewarming phase in the N2O condition compared to the control conditions. Although the thermosensitivity (gain) of shivering appeared preserved during the immersion phase, it was reduced during the N2O rewarming phase.(ABSTRACT TRUNCATED AT 400 WORDS)
Age Modulates Physiological Responses during Fan Use under Extreme Heat and Humidity.
Gagnon, Daniel; Romero, Steven A; Cramer, Matthew N; Kouda, Ken; Poh, Paula Y S; Ngo, Hai; Jay, Ollie; Crandall, Craig G
2017-11-01
We examined the effect of electric fan use on cardiovascular and thermoregulatory responses of nine young (26 ± 3 yr) and nine aged (68 ± 4 yr) adults exposed to extreme heat and humidity. While resting at a temperature of 42°C, relative humidity increased from 30% to 70% in 2% increments every 5 min. On randomized days, the protocol was repeated without or with fan use. HR, core (Tcore) and mean skin (Tsk) temperatures were measured continuously. Whole-body sweat loss was measured from changes in nude body weight. Other measures of cardiovascular (cardiac output), thermoregulatory (local cutaneous and forearm vascular conductance, local sweat rate), and perceptual (thermal and thirst sensations) responses were also examined. When averaged over the entire protocol, fan use resulted in a small reduction of HR (-2 bpm, 95% confidence interval [CI], -8 to 3), and slightly greater Tcore (+0.05°C; 95% CI, -0.13 to 0.23) and Tsk (+0.03°C; 95% CI, -0.36 to 0.42) in young adults. In contrast, fan use resulted in greater HR (+5 bpm; 95% CI, 0-10), Tcore (+0.20°C; 95% CI, 0.00-0.41), and Tsk (+0.47°C; 95% CI, 0.18-0.76) in aged adults. A greater whole-body sweat loss during fan use was observed in young (+0.2 kg; 95% CI, -0.2 to 0.6) but not aged (0.0 kg; 95% CI, -0.2 to 0.2) adults. Greater local sweat rate and cutaneous vascular conductance were observed with fan use in aged adults. Other measures of cardiovascular, thermoregulatory, and perceptual responses were unaffected by fan use in both groups. During extreme heat and humidity, fan use elevates physiological strain in aged, but not young, adults.
Lower skin temperature decreases maximal cycling performance.
Imai, Daiki; Okazaki, Kazunobu; Matsumura, Shinya; Suzuki, Takashi; Miyazawa, Taiki; Suzuki, Akina; Takeda, Ryosuke; Hamamoto, Takeshi; Zako, Tetsuo; Kawabata, Takashi; Miyagawa, Toshiaki
2011-12-01
It is known that external cooling of body regions involved in exercise, prior to exercise, decreases anaerobic performance. However, there have been no studies reporting the effects of whole body skin surface cooling before exercise on maximal anaerobic capacity. In order to clarify the effects, we compared power output during the Wingate anaerobic test between preconditioning by exposure to temperature 10 degrees C and 25 degrees C. Eight healthy males carried out the Wingate test for 30 seconds, after pre-conditioning for 60 minutes using a perfusion suit with water at a temperature of 10 degrees C or 25 degrees C. We evaluated the peak power (PP) and peak power slope (PS) of the power output. Mean skin temperature (T(sk)) at 60 minutes of pre-conditioning in the 10 degrees C trial was significantly lower than in the 25 degrees C trial (p < 0.05). PP and also PS were significantly lower in the 10 degrees C trial than in the 25 degrees C trial. Changes (Δ) in PP between the 10 degrees C trial and the 25 degrees C trial were strongly correlated with ΔT(sk) and Δ in thigh and leg skin temperature (ΔT(thigh) and ΔT(leg), respectively), whereas ΔPS was strongly correlated with ΔT(sk), but not with ΔT(thigh) and ΔT(leg). Whole body skin surface cooling prior to exercise restricts anaerobic capacity, especially in the initial phase of exercise.
Thermoregulatory influence of a cooling vest on hyperthermic athletes.
Lopez, Rebecca M; Cleary, Michelle A; Jones, Leon C; Zuri, Ron E
2008-01-01
Athletic trainers must have sound evidence for the best practices in treating and preventing heat-related emergencies and potentially catastrophic events. To examine the effectiveness of a superficial cooling vest on core body temperature (T(c)) and skin temperature (T(sk)) in hypohydrated hyperthermic male participants. A randomized control design with 2 experimental groups. Participants exercised by completing the heat-stress trial in a hot, humid environment (ambient temperature = 33.1 +/- 3.1 degrees C, relative humidity = 55.1 +/- 8.9%, wind speed = 2.1 +/- 1.1 km/hr) until a T(c) of 38.7 +/- 0.3 degrees C and a body mass loss of 3.27 +/- 0.1% were achieved. Ten healthy males (age = 25.6 +/- 1.6 years, mass = 80.3 +/- 13.7 kg). Recovery in a thermoneutral environment wearing a cooling vest or without wearing a cooling vest until T(c) returned to baseline. Rectal T(c), arm T(sk), time to return to baseline T(c), and cooling rate. During the heat-stress trial, T(c) significantly increased (3.6%) and, at 30 minutes of recovery, T(c) had decreased significantly (2.6%) for both groups. Although not significant, the time for return to baseline T(c) was 22.6% faster for the vest group (43.8 +/- 15.1 minutes) than for the no-vest group (56.6 +/- 18.0 minutes), and the cooling rate for the vest group (0.0298 +/- 0.0072 degrees C/min) was not significantly different from the cooling rate for the no-vest group (0.0280 +/- 0.0074 degrees C/min). The T(sk) during recovery was significantly higher (2.1%) in the vest group than in the no-vest group and was significantly lower (7.1%) at 30 minutes than at 0 minutes for both groups. We do not recommend using the cooling vest to rapidly reduce elevated T(c). Ice-water immersion should remain the standard of care for rapidly cooling severely hyperthermic individuals.
2015-09-01
skin)and)used)as) a)marker)of)fibrosis)[3,)4]),)we)assessed)both) protein )and)mRNA)levels)in)fibroblasts)that)received)DNA)from)a) plasmid...containing)a)single)allele)of)a)single)Col3a1%gene.)In)three)independent)experiments,)COL1A1) protein ) was)significantly)elevated)after)48)hours)of)transfection...Mouse& Col3a1eKO& fibroblasts& transfected& with& a& plasmid& bearing&the&mutant&Col3a1Tsk2&express&34%&more&COL1A1& protein &than& Col3a1WT
2012-07-01
Philadelphia, PA 19104 1 Jul 2011 - 30 Jun 2012Annual01-07-2012 This project is focused on an animal model of the human disease, systemic sclerosis ...earliest indicator of tight-skin in the tissue Animal model, systemic sclerosis , scleroderma, Tsk2/+, fibrosis, gene, genetics, TGFβ 35 eblanken...the multiple clinical parameters of fibrotic disease from birth onward. BODY Milestones were assigned to this proposal, with tasks to be
NASA Astrophysics Data System (ADS)
Lee, Soomin; Fujimura, Hiroko; Shimomura, Yoshihiro; Katsuura, Tetsuo
2015-09-01
Recently, a growing number in Japan are switching to taking baths in the morning (morning bathing). However, the effects of the morning bathing on human physiological functions and work efficiency have not yet been revealed. Then, we hypothesized that the effect of morning bathing on physiological functions would be different from those of night bathing. In this study, we measured the physiological functions and work efficiency during the day following the morning bathing (7:10-7:20) including showering, mist sauna bathing, and no bathing as a control. Ten male healthy young adults participated in this study as the subjects. We evaluated the rectal temperature (Tre), skin temperature (Tsk), heart rate (HR), heart rate variability (HRV), blood pressure (BP), the relative power density of the alpha wave (α-wave ratio) of electroencephalogram, alpha attenuation coefficient (AAC), and the error rate of the task performance. As a result, we found that the HR after the mist sauna bathing was significantly lower than those after no bathing rest 3 (11:00). Furthermore, we verified that the α-wave ratio of the Pz after the mist sauna bathing was significantly lower than those after no bathing during the task 6 (15:00). On the other hand, the α-wave ratio of the Pz after the mist sauna bathing was significantly higher than those after showering during the rest 3 (11:00). Tsk after the mist sauna bathing was higher than those after the showering at 9:00 and 15:00. In addition, the error rate of the task performance after the mist sauna bathing was lower than those after no bathing and showering at 14:00. This study concludes that a morning mist sauna is safe and maintains both skin temperature compared to other bathing methods. Moreover, it is presumed that the morning mist sauna bathing improves work efficiency comparing other bathing methods during the task period of the day following the morning bathing.
NASA Technical Reports Server (NTRS)
Greenleaf, J. E.; Hutchinson, T.; Shaffer-Bailey, M.; Looft-Wilson, R.
1996-01-01
The purpose was to investigate the mechanism for the excessive exercise hyperthermia following deconditioning (reduction of physical fitness). Rectal (Tre) and mean skin (Tsk) temperatures and thermoregulatory responses were measured in six men [mean (SD) age, 32 (6) years; mass, 78.26 (5.80) kg; surface area, 1.95 (0.11) m2; maximum oxygen uptake (VO2max), 48 (6) ml.min-1.kg-1; whilst supine in air at dry bulb temperature 23.2 (0.6) degree C, relative humidity 31.1 (11.1)% and air speed 5.6 (0.1) m.min-1] during 70 min of leg cycle exercise [51 (4)% VO2max] in ambulatory control (AC), or following 6 h of chair rest (CR), 6 degree head-down bed rest (BR), and 20 degree (WI20) and 80 degree (WI80) foot-down water immersion [water temperature, 35.0 (0.1) degree C]. Compared with the AC exercise delta Tre [mean (SD) 0.77 (0.13) degree C (*P < 0.05), after WI80 0.96 (0.13) degree C*, and after WI20 1.03 (0.09) degree C*. All Tsk responded similarly to exercise: they decreased (NS) by 0.5-0.7 degree C in minutes 4-8 and equilibrated at +0.1 to +0.5 degree C at 60-70. Skin heat conductance was not different among the five conditions (range = 147-159 kJ.m-2.h-1.degree C-1). Results from an intercorrelation matrix suggested that total body sweat rate was more closely related to Tre at 70 min (Tre70) than limb sweat rate or blood flow. Only 36% of the variability in Tre70 could be accounted for by total sweating, and less than 10% from total body dehydration. It would appear that multiple factors are involved which may include change in sensitivity of thermo- and osmoreceptors.
Lee, Soomin; Fujimura, Hiroko; Shimomura, Yoshihiro; Katsuura, Tetsuo
2015-09-01
Recently, a growing number in Japan are switching to taking baths in the morning (morning bathing). However, the effects of the morning bathing on human physiological functions and work efficiency have not yet been revealed. Then, we hypothesized that the effect of morning bathing on physiological functions would be different from those of night bathing. In this study, we measured the physiological functions and work efficiency during the day following the morning bathing (7:10-7:20) including showering, mist sauna bathing, and no bathing as a control. Ten male healthy young adults participated in this study as the subjects. We evaluated the rectal temperature (Tre), skin temperature (Tsk), heart rate (HR), heart rate variability (HRV), blood pressure (BP), the relative power density of the alpha wave (α-wave ratio) of electroencephalogram, alpha attenuation coefficient (AAC), and the error rate of the task performance. As a result, we found that the HR after the mist sauna bathing was significantly lower than those after no bathing rest 3 (11:00). Furthermore, we verified that the α-wave ratio of the Pz after the mist sauna bathing was significantly lower than those after no bathing during the task 6 (15:00). On the other hand, the α-wave ratio of the Pz after the mist sauna bathing was significantly higher than those after showering during the rest 3 (11:00). Tsk after the mist sauna bathing was higher than those after the showering at 9:00 and 15:00. In addition, the error rate of the task performance after the mist sauna bathing was lower than those after no bathing and showering at 14:00. This study concludes that a morning mist sauna is safe and maintains both skin temperature compared to other bathing methods. Moreover, it is presumed that the morning mist sauna bathing improves work efficiency comparing other bathing methods during the task period of the day following the morning bathing.
Effects of hyperoxia on thermoregulatory responses during feet immersion to hot water in humans.
Yamashita, Kazuaki; Tochihara, Yutaka
2003-07-01
This study examined effects of hyperoxia on thermoregulatory responses. Eight healthy male students (23.5+/-1.8 yrs) were involved in this study. They immersed their legs in a hot water bath (42 degrees C) for 60 minutes in a climate chamber. The conditions of oxygen concentration of a chamber were set at 21% (control), 25% (25%O(2)), and 30% (30%O(2)). Ambient temperature and relative humidity was maintained at 25 degrees C and 50% in every condition, respectively. Measurements included rectal temperature (Tre), skin temperature at 7 sites, laser Doppler flowmeter (LDF) on the back and forearm as an index of skin blood flow, heart rate, local sweat rate (Msw) on the back and forearm, and total body weight loss (BWL). Increases of Tre at 25%O(2) and 30%O(2) tended to be lower during the immersion than in the control. Mean skin temperature (Tsk) of the control increased gradually after the onset of sweating, while the Tsks at 25%O(2) and 30%O(2) maintained a constant level during sweating. LDFs on the forearm at 25%O(2) and 30%O(2) showed lower increases compared with the control. No significant differences in Msw on the back and the forearm and BWL were seen among the conditions. These results suggested that hyperoxia could not affect sweating responses but elicit an inhibitory effect on thermoregulatory skin blood flow.
Physiological Responses to Overdressing and Exercise-Heat Stress in Trained Runners.
Ely, Brett R; Blanchard, Laurie A; Steele, Jared R; Francisco, Michael A; Cheuvront, Samuel N; Minson, Christopher T
2018-06-01
Heat acclimation is the best strategy to improve performance in a hot environment. Many athletes seeking the benefits of heat acclimation lack access to a hot environment for exercise and, thus, rely on overdressing to simulate environmental heat stress. It is currently unknown whether this approach produces the requisite thermoregulatory strain necessary for heat acclimation in trained men and women. To compare physiological and cellular responses to exercise in a hot environment (HOT; 40°C, 30% RH) with minimal clothing (clo = 0.87) and in a temperate environment (CLO; 15°C, 50% RH) with overdressing (clo = 1.89) in both men and women. HR, rectal temperature (Tre), mean skin temperature (Tsk), sweating rate (SR), and extracellular heat shock protein (eHSP)72 were measured in 13 (7 males, 6 females) well-trained runners (V˙O2max: 58.7 ± 10.7 mL·kg·min) in response to ~60 min of treadmill running at 50%-60% V˙O2max in HOT and CLO. Tre increased in both conditions, but the increase was greater in HOT (ΔTre HOT: 2.6°C ± 0.1°C; CLO 2.0°C ± 0.1°C; P = 0.0003). SR was also higher in HOT (1.41 ± 0.1 L h; CLO: 1.16 ± 0.1 L·h; P = 0.0001). eHSP72 increased in HOT (% change: 59% ± 11%; P = 0.03) but not in CLO (6% ± 2%; P = 0.31). Mean Tsk and HR were not different between HOT and CLO in men but were higher in HOT for women. These data support the idea that overdressing during exercise in a temperate environment may produce the high Tre, Tsk, HR, and SR necessary for adaptation, but these responses do not match those in hot, dry environments. It is possible that greater exercise stimulus, warmer environment, or more clothing may be required to allow for a similar level of acclimation.
Body fatness, body core temperature, and heat loss during moderate-intensity exercise.
Limbaugh, Jayme D; Wimer, Gregory S; Long, Lynn H; Baird, William H
2013-11-01
This study examined the influence of body fatness on body core temperature and heat loss responses during moderate-intensity exercise. Nine men with lower body fat and eight men with higher body fat, matched for aerobic fitness, completed 1 h of recumbent cycling at the same absolute intensity in a warm environment (30 degrees C, 40% RH). Percent body fat was measured by hydrostatic weighing, using oxygen dilution to determine residual volume. Esophageal temperature (T(es)), mean skin temperature (T(sk)), and local sweat rate (m(sw)) were measured at rest and continuously during exercise while forearm blood flow (FBF) was measured at rest and every 10 min during exercise. The lower body fat and higher body fat groups were successfully matched for aerobic fitness, removing the influence of body fatness, given that V/O2(peak) was 50.72 +/- 7.34 and 50.43 +/- 5.01 ml x kg LBM(-1) x min(-1), respectively. When compared to lower body fat individuals, % body fat, body surface area (A(D)), and body mass were higher and A(D)/ mass was lower in higher body fat individuals. T(es), T(sk), FBF, m(sw), and the slope of m(sw):T(es) were not different between groups. Metabolic heat production was similar between the lower body fat (299.7 +/- 40.5 W x m(-2)) and higher body fat (288.1 +/- 30.6 W x m(-2)) subjects, respectively. Dry and evaporative heat loss, as well as heat storage during exercise, were not different between groups. These data suggest that there is no effect of body fatness on body core temperature or heat loss responses during moderate-intensity exercise in a warm environment.
Relationship between skin blood flow and sweating rate, and age related regional differences.
Inoue, Y; Shibasaki, M; Hirata, K; Araki, T
1998-12-01
To examine the mechanisms and regional differences in the age-related decrement of skin blood flow, 11 young (age 20-25 years) and 10 older (age 64-76 years) men were exposed to a mild heat stress by immersing their feet and lower legs in water at 42 degrees C for 60 min, while they were sitting in near thermoneutral conditions [25 degrees C and 45% relative humidity (rh)]. During the equilibrium period (25 degrees C and 45% rh) before the heat test, no group differences were observed in rectal (Tre) and mean skin (Tsk) temperatures or mean arterial pressure (MAP). During passive heating, Tsk was significantly lower in the older men 20 min after commencing exposure (P<0.001), although there were similar increases in Tre in both groups. Exposure time and age did not affect MAP. The local sweating rate (m(sw)) and the percentage change in skin blood flow by laser Doppler flowmetry (%LDF) relative to baseline values on the chest, back, forearm and thigh were significantly lower in the older men (P<0.001), especially on the thigh. After starting the heat exposure, three temporal phases were observed in the relationship between %LDF and m(sw) at most sites in each subject. In phase A, %LDF increased but with no increase in m(sw). In phase B, m(sw) increased but with no secondary increase in %LDF. Finally, in phase C, there were proportional increases in %LDF and m(sw). The increase in %LDF in phase A was significantly lower on the forearm and thigh (P<0.05) for the older men, but not on the chest and back. In phase C, the slopes of the regression lines between %LDF and m(sw) were lower for the older men on the back (P<0.03), forearm (P = 0.08) and thigh (P<0.03), but not on the chest. These results would suggest that the age-related decrement in skin blood flow in response to passive heating may be due in part to a smaller release of vasoconstrictor tone and to less active vasodilatation once sweating begins. Regional differences exist in the impaired vasoconstriction and active vasodilatation systems.
North Pole Marathon Laboratory Lessons and Field Success.
Barwood, Martin J; Burrows, Holly; Cessford, Jessica
2016-05-01
This case study documents the training, laboratory preparation, and in-race performance data from Great Britain's top finisher in the 13(th) edition of the UVU North Pole Marathon. We report data from a preparatory laboratory test in simulated cold conditions (-15°C) with and without wind chill during high- and low-intensity expected 'race pace' running. These tests examined the adequacy of the selected clothing assembly and provided recommendations for the race. The tests established that there was no risk of hypothermia, as the clothing assembly provided too much insulation; terminal rectal temperature was 39.25°C. Skin temperature (Tsk) data revealed no impending risk of frostbite; nadir Tsk was 20.2°C at the hamstring. Oxygen consumption data revealed the self-selected high intensity was potentially not sustainable based on estimates of substrate utilization. We recommended: 1) a maximum running speed; 2) some of the clothing base layers could be removed pre-race; 3) vents and/or zips could be used to offload or retain heat; and 4) an even pacing profile should be adopted. The participant completed the race in 6:55:24 (h:mm:ss) in temperatures of -41°C. GPS data revealed a positive pacing template (i.e., marginally quicker in the first half). Neither hypothermia nor frostbite occurred. Peak pace from the laboratory tests was not consistently exceeded. Marathon performance can be undertaken in one of the world's most inhospitable environments when careful consideration is given to clothing insulation and exercise intensity by planning for the dynamic thermal changes that may occur as the race ensues.
Exercise-heat acclimation in young and older trained cyclists.
Best, Stuart; Thompson, Martin; Caillaud, Corinne; Holvik, Liv; Fatseas, George; Tammam, Amr
2014-11-01
The purpose of this study was to investigate the effect of age on the capacity to acclimatise to exercise-heat stress. This study hypothesised that age would not affect body temperature and heat loss effector responses to short-term exercise-heat acclimation in trained subjects. Seven young subjects (19-32 years) were matched with 7 older subjects (50-63 years). Subjects were highly trained but not specifically heat acclimated when they exercised for 60 min at 70%VO2max in hot-dry (35 °C, 40%RH) and thermoneutral (20 °C, 40%RH) conditions, pre and post 6 days of exercise-heat acclimation (70%VO2max, 35 °C, 40%RH). Rectal temperature (Tr), skin temperature (Tsk), heart rate (HR), cutaneous vascular conductance (CVC) and whole body sweat loss (Msw) were measured during each testing session and Tr and HR were measured during each acclimation session. Tr, Tsk, %HRmax, CVC and Msw were similar across age groups both pre and post heat acclimation. Following heat acclimation relative decreases and increases in Tr and Msw, respectively, were similar in both subject groups. There was a significant reduction in heart rate (%HRmax) and increase in final CVC following the acclimation programme in the young group (all p < 0.05) but not the older group. When comparing young and older well trained adults we found age affected the cardiovascular adaptation but not body temperature or whole body sweat loss to exercise-heat acclimation. These data suggest age does not affect the capacity to acclimatise to exercise-heat stress in highly trained adults undergoing short-term heat acclimation. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
2013-09-01
define CSTR .5 // 1/°C #define SKBFN 6.3 // liters/(h m^2) #define Skbfmax 90. // conservative could be higher for fit person 36 #define...WarmC=0; if (Tsk<TTSK) Colds=TTSK-Tsk; if (Tc>TTCR) WarmC=Tc-TTCR; Skbf=(SKBFN+CDIL*WarmC)/(1+ CSTR *Colds); // Liters/(h m^2) if (Skbf
Gillis, D Jason; Barwood, M J; Newton, P S; House, J R; Tipton, M J
2016-05-01
This study assessed whether donning a garment saturated with menthol and ethanol (M/E) can improve evaporative cooling and thermal perceptions versus water (W) or nothing (CON) during low intensity exercise and rest in warm, humid conditions often encountered in recreational/occupational settings. It was hypothesised there would be no difference in rectal (Tre) and skin (Tsk) temperature, infra-red thermal imagery of the chest/back, thermal comfort (TC) and rating of perceived exertion (RPE) between M/E, W and CON, but participants would feel cooler in M/E versus W or CON. Six volunteers (mean [SD] 22 [4] years, 72.4 [7.4] kg and 173.6 [3.7] cm) completed (separate days) three, 60-min tests in 30°C, 70%rh, in a balanced order. After 15-min of seated rest participants donned a dry (CON) or 80mL soaked (M/E, W) long sleeve shirt appropriate to their intervention. They then undertook 30-min of low intensity stepping at a rate of 12steps/min on a 22.5cm box, followed by 15-min of seated rest. Measurements included heart rate (HR), Tre, Tsk (chest/back/forearm), thermal imaging (back/chest), thermal sensation (TS), TC and RPE. Data were reported every fifth minute as they changed from baseline and the area under the curves were compared by condition using one-way repeated measures ANOVA, with an alpha level of 0.05. Tre differed by condition, with the largest heat storage response observed in M/E (p<0.05). Skin temperature at the chest/back/forearm, and thermal imaging of the chest all differed by condition, with the greatest rate of heat loss observed in W and M/E respectively (p<0.01). Thermal sensation differed by condition, with the coolest sensations observed in M/E (p<0.001). No other differences were observed. Both M/E and W enhanced evaporative cooling compared CON, but M/E causes cooler sensations and a heat storage response, both of which are likely mediated by menthol. Copyright © 2016 Elsevier Ltd. All rights reserved.
Jovanović, Dalibor; Karkalić, Radovan; Zeba, Snjezana; Pavlović, Miroslav; Radaković, Sonja S
2014-03-01
In military services, emergency situations when soldiers are exposed to a combination of nuclear, biological and chemical (NBC) contamination combined with heat stress, are frequent and complex. In these specific conditions, usage of personal body cooling systems may be effective in reducing heat stress. The present study was conducted in order to evaluate the efficiency of four various types of contemporary personal body cooling systems based on the "Phase Change Material" (PCM), and its effects on soldiers' subjective comfort and physiological performance during exertional heat stress in hot environments. Ten male soldiers were voluntarily subjected to exertional heat stress tests (EHSTs) consisted of walking on a treadmill (5.5 km/h) in hot conditions (40 degreesC) in climatic chamber, wearing NBC isolating impermeable protective suits. One of the tests was performed without any additional cooling solution (NOCOOL), and four tests were performed while using different types of cooling systems: three in a form of vests and one as underwear. Physiological strain was determined by the mean skin temperature (Tsk), tympanic temperature (Tty), and heart rate values (HR), while sweat rates (SwR) indicated changes in hydration status. In all the cases EHST induced physiological response manifested through increasing Tty, HR and SwR. Compared to NOCOOL tests, when using cooling vests, Tty and Tsk were significantly lower (on 35th min, for 0.44 +/- 0.03 and 0.49 +/- 0.05 degrees C, respectively; p < 0.05), as well as the average SwR (0.17 +/- 0.03 L/m2/h). When using underwear, the values of given parameters were not significantly different compared to NOCOOL tests. Using a body cooling system based on PCM in the form of vest under NBC protective clothes during physical activity in hot conditions, reduces sweating and alleviates heat stress manifested by increased core and skin temperatures and heart rate values. These effects directly improve heat tolerance, hydration state, decrease in the risk of heat illness, and extends the duration of soldiers' exposure to extreme conditions.
Saat, Mohamed; Sirisinghe, Roland Gamini; Singh, Rabindarjeet; Tochihara, Yutaka
2005-09-01
This study investigates the effects of a short-term aerobic training program in a hot environment on thermoregulation, blood parameters, sweat secretion and composition in tropic-dwellers who have been exposed to passive heat. Sixteen healthy Malaysian-Malay male volunteers underwent heat acclimation (HA) by exercising on a bicycle ergometer at 60% of VO2max for 60 min each day in a hot environment (Ta: 31.1+/-0.1 degrees C, rh: 70.0+/-4.4%) for 14 days. All parameters mentioned above were recorded on Day 1 and at the end of HA (Day 16). On these two days, subjects rested for 10 min, then cycled at 60% of VO2max for 60 min and rested again for 20 min (recovery) in an improvised heat chamber. Rectal temperature (Tre), mean skin temperature (Tsk) heart rate (HR), ratings of perceived exertion (RPE), thermal sensation (TS), local sweat rate and percent dehydration were recorded during the test. Sweat concentration was analysed for sodium [Na+]sweat and potassium. Blood samples were analysed for biochemical changes, electrolytes and hematologic indices. Urine samples were collected before and after each test and analysed for electrolytes.After the period of acclimation the percent dehydration during exercise significantly increased from 1.77+/-0.09% (Day 1) to 2.14+/-0.07% (Day 16). Resting levels of hemoglobin, hematocrit and red blood cells decreased significantly while [Na+]sweat increased significantly. For Tre and Tsk there were no differences at rest. Tre, HR, RPE, TS, plasma lactate concentration, hemoglobin and hematocrit at the 40th min of exercise were significantly lower after the period of acclimation but mean corpuscular hemoglobin and serum osmolality were significantly higher while no difference was seen in [Na+]sweat and Tsk. It can be concluded that tropic-dwelling subjects, although exposed to prolonged passive heat exposure, were not fully heat acclimatized. To achieve further HA, they should gradually expose themselves to exercise-heat stress in a hot environment.
Quinn, Tyler; Kim, Jung-Hyun; Seo, Yongsuk; Coca, Aitor
2018-06-01
IntroductionPersonal protective equipment (PPE) recommended for use in West Africa during the Ebola outbreak increased risk for heat illness, and countermeasures addressing this issue would be valuable.Hypothesis/ProblemThe purpose of this study was to examine the physiological impact and heat perception of four different personal cooling devices (PCDs) under impermeable PPE during low-intensity exercise in a hot and humid environment using thermal manikin modeling and human testing. Six healthy male subjects walked on a treadmill in a hot/humid environment (32°C/92% relative humidity [RH]) at three metabolic equivalents (METs) for 60 minutes wearing PPE recommended for use in West Africa and one of four different personal cooling devices (PCDs; PCD1, PCD2, PCD3, and PCD4) or no PCD for control (CON). The same ensembles were tested with thermal manikin modeling software in the same conditions to compare the results. All PCDs seemed to reduce physiological heat stress characteristics when worn under PPE compared to CON. Both the manikin and human testing provided similar results in core temperature (Tc) and heat sensation (HS) in both magnitude and relationship. While the manikin and human data provided similar skin temperature (Tsk) characterization, Tsk estimation by the manikin seemed to be slightly over-estimated. Weight loss, as estimated by the manikin, was under-estimated compared to the human measurement. Personal cooling device use in conjunction with impermeable PPE may be advantageous in mitigating physiological and perceptual burdens of heat stress. Evaluation of PCDs worn under PPE can be done effectively via human or manikin testing; however, Tsk may be over-estimated and weight loss may be under-estimated. Thermal manikin testing of PCDs may provide fast and accurate information to persons recommending or using PCDs with PPE. QuinnT, KimJH, SeoY, CocaA. Comparison of thermal manikin modeling and human subjects' response during use of cooling devices under personal protective ensembles in the heat. Prehosp Disaster Med. 2018;33(3):279-287.
Effects of normobaric hypoxic bed rest on the thermal comfort zone.
Ciuha, Ursa; Eiken, Ola; Mekjavic, Igor B
2015-01-01
Future Lunar and Mars habitats will maintain a hypobaric hypoxic environment to minimise the risk of decompression sickness during the preparation for extra-vehicular activity. This study was part of a larger study investigating the separate and combined effects of inactivity associated with reduced gravity and hypoxia, on the cardiovascular, musculoskeletal, neurohumoural, and thermoregulatory systems. Eleven healthy normothermic young male subjects participated in three trials conducted on separate occasions: (1) Normobaric hypoxic ambulatory confinement, (2) Normobaric hypoxic bedrest and (3) Normobaric normoxic bedrest. Normobaric hypoxia was achieved by reduction of the oxygen fraction in the air (FiO2 = 0.141 ± 0.004) within the facility, while the effects of reduced gravity were simulated by confining the subjects to a horizontal position in bed, with all daily routines performed in this position for 21 days. The present study investigated the effect of the interventions on behavioural temperature regulation. The characteristics of the thermal comfort zone (TCZ) were assessed by a water-perfused suit, with the subjects instructed to regulate the sinusoidally varying temperature of the suit within a range considered as thermally comfortable. Measurements were performed 5 days prior to the intervention (D-5), and on days 10 (D10) and 20 (D20) of the intervention. no statistically significant differences were found in any of the characteristics of the TCZ between the interventions (HAMB, HBR and NBR), or between different measurement days (D-5, D10, D20) within each intervention. rectal temperature remained stable, whereas skin temperature (Tsk) increased during all interventions throughout the one hour trial. no difference in Tsk between D-5, D10 and D20, and between HAMB, HBR and NBR were revealed. subjects perceived the regulated temperature as thermally comfortable, and neutral or warm. we conclude that regulation of thermal comfort is not compromised by hypoxic inactivity. Copyright © 2015 Elsevier Ltd. All rights reserved.
2014-09-01
onto an 8% SDS gel. Proteins were transferred to a polyvinylidene fluoride membrane, blocked in 5% nonfat milk in Tris-buffered saline, probed with...fibrosis (shown to be expressed at high levels in Tsk2/+ skin and used as a marker of fibrosis [3, 4]), we assessed both protein and mRNA levels in...fibroblasts that received DNA from a plasmid containing a single allele of a single Col3a1 gene. In three independent experiments, COL1A1 protein was
Lopachin, R M; Rudy, T A
1982-12-01
1. We have examined the effects on thermoregulation in the rat of noradrenaline bitartrate (NA), 5-hydroxytryptamine hydrochloride (5-HT) and carbamylcholine chloride (CCh) injected into the lumbar spinal subarachnoid space via a chronic indwelling catheter.2. Intrathecal injections of the monoamines and CCh reproducibly affected thermoregulation, whereas injections of control solutions had no effect.3. Intrathecal injections of NA (0.01-0.30 mumol) produced a dose-dependent hypothermia associated with a decrease in tail skin vasomotor tone. Shivering activity was not depressed during the hypothermia and sometimes increased. Intrathecal administration of the alpha-adrenergic agonist clonidine (0.0175-0.070 mumol) elicited changes in T(c) and T(sk) similar to those induced by intrathecal NA.4. Intrathecal 5-HT (0.030-0.90 mumol) elicited a dose-dependent hyperthermia accompanied by increased tail skin vasomotor tone and increased shivering.5. CCh injected intrathecally (0.001-0.06 mumol) evoked a dose-dependent hyperthermia. During the period when core temperature was rising, tail skin vasomotor tone increased and shivering-like activity was present. Once the maximum core temperature had been reached, tail skin vasodilatation occurred. Vasodilatation persisted until core temperature had returned to normal.6. Intravenous injections of 5-HT (0.30 and 0.90 mumol) or CCh (0.006 and 0.03 mumol) caused no thermoregulatory effect. The effects of these agents injected intrathecally were therefore not due to an action in the periphery.7. Intravenous infusions of NA (0.06 and 0.10 mumol) produced hypothermia and transient tail skin vasodilatation. We suggest that an action at peripheral sites may have contributed to the effects produced by intrathecal injection of this monamine.8. These findings suggest that spinal noradrenergic, serotonergic and cholinergic synapses may be importantly involved in the control of body temperature in the rat. The possible functional roles of these synapses and the putative spinal sites of action of the injected substances are discussed.
Tissue temperature profile in the human forearm during thermal stress at thermal stability.
Ducharme, M B; VanHelder, W P; Radomski, M W
1991-11-01
The purpose of the present study was to investigate the effect of a range of water temperatures (Tw from 15 to 36 degrees C) on the tissue temperature profile of the resting human forearm at thermal stability. Tissue temperature (Tti) was continuously monitored by a calibrated multicouple probe during 3 h of immersion of the forearm. The probe was implanted approximately 9 cm distal from the olecranon process along the ulnar ridge. Tti was measured every 5 mm, from the longitudinal axis of the forearm (determined from computed tomography scanning) to the skin surface. Along with Tti, skin temperature (Tsk), rectal temperature (Tre), and blood flow were measured during the immersions. For all temperature conditions, the temperature profile inside the limb was linear as a function of the radial distance from the forearm axis (P less than 0.001). Temperature gradient measured in the forearm ranged from 0.2 +/- 0.1 degrees C C cm (Tw = 36 degrees C) to 2.3 +/- 0.5 degrees C cm (Tw = 15 degrees C). The maximal Tti was measured in all cases at the longitudinal axis of the forearm and was in all experimental conditions lower than Tre. On immersion at Tw less than 36 degrees C, the whole forearm can be considered to be part of the shell of the body. With these experimental data, mathematical equations were developed to predict, with an accuracy of at least 0.6 degrees C, the Tti at any depth inside the forearm at steady state during thermal stress.(ABSTRACT TRUNCATED AT 250 WORDS)
Physiological strain of stock car drivers during competitive racing.
Carlson, Lara A; Ferguson, David P; Kenefick, Robert W
2014-08-01
Heat strain experienced by motorsport athletes competing in National Association for Stock Car Automobile Racing (NASCAR) may be significant enough to impair performance or even result in a life-threatening accident. There is a need to carefully quantify heat strain during actual NASCAR race competitions in order to faithfully represent the magnitude of the problem and conceptualize future mitigation practices. The purpose of this investigation was to quantify the thermoregulatory and physiological strain associated with competitive stock car driving. Eight male stock car drivers (29.0±10.0yr; 176.2±3.3cm, 80.6±15.7kg) participated in sanctioned stock car races. Physiological measurements included intestinal core (Tc) and skin (Tsk) temperatures, heart rate (HR), blood pressure, and body mass before and after completion of the race. Pre-race Tc was 38.1±0.1°C which increased to 38.6±0.2°C post-race (p=0.001). Tsk increased from 36.1±0.2°C pre-race to 37.3±0.3°C post-race (p=0.001) whereas the core-to-skin temperature gradient decreased from a pre-race value of 2.0±0.3°C to 1.3±0.3°C post-race (p=0.005). HRs post-race were 80±0.1% of the drivers' age-predicted maximum HR. Physiological Strain Index (PSI) post-race was 4.9, which indicates moderate strain. Drivers' thermal sensation based on the ASHRAE Scale increased from 1.3±0.5 to 2.8±0.4, and their perception of exertion (RPE) responses also increased from 8.4±1.6 to 13.9±1.8 after competition. Heat strain associated with competitive stock car racing is significant. These findings suggest the need for heat mitigation practices and provide evidence that motorsport should consider strategies to become heat acclimatized to better meet the thermoregulatory and cardiovascular challenges of motorsport competition. Copyright © 2014 Elsevier Ltd. All rights reserved.
Barwood, Martin J; Newton, Phillip S; Tipton, Michael J
2009-04-01
Recent research has focused on developing air-ventilated garments to improve evaporative cooling in military settings. This study assessed a ventilated vest (Vest) in hot (45 degrees C), dry (10% RH) ambient conditions over 6 h of rest and exercise. It was hypothesized that the Vest would lower the thermal strain and increase the amount of exercise done by subjects. Eight healthy heat-acclimated men, wearing combat clothing, body armor, and a 19-kg load in webbing walked on a treadmill at 5 km h(-1) at a 2% incline until rectal temperature (T(rec)) reached 38.5 degrees C. They then rested until T(re) reached 38 degrees C, at which point they recommenced walking. On one occasion the subjects wore a Vest, blowing ambient air around the torso. On the second occasion subjects did not wear the vest (NoVest). Exercise/rest ratio, T(rec), skin temperature (T(sk)), sweat responses, rating of perceived exertion (RPE), and thermal comfort (TC) were measured. Subjects wearing theVest exercised for significantly longer (18%; 11 min/h) as a percentage of total exposure time, stopped exercise significantly less often [Mean (SD); NoVest: 3 (2) stops; Vest: 1 (2) stops], and maintained significantly lower skin temperature under the body armor [T(chest): NoVest 37.55 (0.51) degrees C; Vest: 35.33 (1.00) degrees C; T(back): NoVest: 36.85 (0.83) degrees C; Vest: 35.84 (0.88) degrees C]. The Vest provided 28 W of cooling during exercise and 73 W when at rest as estimated by thermometry. A ventilated vest can provide cooling, and thereby reduce thermal strain and increase exercise done in dry environmental temperatures up to 45 degrees C, without causing skin irritation and discomfort.
Effects of airflow on body temperatures and sleep stages in a warm humid climate
NASA Astrophysics Data System (ADS)
Tsuzuki, Kazuyo; Okamoto-Mizuno, Kazue; Mizuno, Koh; Iwaki, Tatsuya
2008-03-01
Airflow is an effective way to increase heat loss—an ongoing process during sleep and wakefulness in daily life. However, it is unclear whether airflow stimulates cutaneous sensation and disturbs sleep or reduces the heat load and facilitates sleep. In this study, 17 male subjects wearing short pyjamas slept on a bed with a cotton blanket under two of the following conditions: (1) air temperature (Ta) 26°C, relative humidity (RH) 50%, and air velocity (V) 0.2 m s-1; (2) Ta 32°C, RH 80%, V 1.7 m s-1; (3) Ta 32°C; RH 80%, V 0.2 m s-1 (hereafter referred to as 26/50, 32/80 with airflow, and 32/80 with still air, respectively). Electroencephalograms, electrooculograms, and mental electromyograms were obtained for all subjects. Rectal (Tre) and skin (Ts) temperatures were recorded continuously during the sleep session, and body-mass was measured before and after the sleep session. No significant differences were observed in the duration of sleep stages between subjects under the 26/50 and 32/80 with airflow conditions; however, the total duration of wakefulness decreased significantly in subjects under the 32/80 with airflow condition compared to that in subjects under the 32/80 with still air condition ( P < 0.05). Tre, Tsk, Ts, and body-mass loss under the 32/80 with airflow condition were significantly higher compared to those under the 26/50 condition, and significantly lower than those under the 32/80 with still air condition ( P < 0.05). An alleviated heat load due to increased airflow was considered to exist between the 32/80 with still air and the 26/50 conditions. Airflow reduces the duration of wakefulness by decreasing Tre, Tsk, Ts, and body-mass loss in a warm humid condition.
Effect of heat on firefighters' work performance and physiology.
Larsen, Brianna; Snow, Rodney; Aisbett, Brad
2015-10-01
Wildland firefighters often perform their duties under both hot and mild ambient temperatures. However, the direct impact of different ambient temperatures on firefighters' work performance has not been quantified. This study compared firefighters' work performance and physiology during simulated wildland firefighting work in hot (HOT; 32°C, 43% RH) and temperate (CON; 19°C, 56% RH) conditions. Firefighters (n=38), matched and allocated to either the CON (n=18) or HOT (n=20) condition, performed simulated self-paced wildland fire suppression tasks (e.g., hose rolling/dragging, raking) in firefighting clothing for six hours, separated by dedicated rest breaks. Task repetitions were counted (and converted to distance or area). Core temperature (Tc), skin temperature (Tsk), and heart rate were recorded continuously throughout the protocol. Urine output was measured before and during the protocol, and urine specific gravity (USG) analysed, to estimate hydration. Ad libitum fluid intake was also recorded. There were no differences in overall work output between conditions for any physical task. Heart rate was higher in the HOT (55±2% HRmax) compared to the CON condition (51±2% HRmax) for the rest periods between bouts, and for the static hose hold task (69±3% HRmax versus 65±3% HRmax). Tc and Tsk were 0.3±0.1°C and 3.1±0.2°C higher in the HOT compared to the CON trial. Both pre- and within- shift fluid intake were increased two-fold in the heat, and participants in the heat recorded lower USG results than their CON counterparts. There was no difference between the CON and HOT conditions in terms of their work performance, and firefighters in both experimental groups increased their work output over the course of the simulated shift. Though significantly hotter, participants in the heat also managed to avoid excessive cardiovascular and thermal strain, likely aided by the frequent rest breaks in the protocol, and through doubling their fluid intake. Therefore, it can be concluded that wildland firefighters are able to safely and efficiently perform their duties under hot conditions, at least over six hours. Copyright © 2015 Elsevier Ltd. All rights reserved.
2012-07-01
Scleroderma in the Tsk/2 Mouse Strain: Implications for Human Scleroderma Pathogenesis and Subset Distinctions PRINCIPAL INVESTIGATOR: Michael...SUBTITLE Identification of the Gene Scleroderma in the Tsk/2 Mouse Strain: Implications 5a. CONTRACT NUMBER for Human Scleroderma Pathogenesis and...Tsk2/+ mouse model of scleroderma .” Drexel University College of Medicine, Discovery Day Research Symposium, Philadelphia, Pennsylvania
Passive Heating Attenuates Post-exercise Cardiac Autonomic Recovery in Healthy Young Males
Peçanha, Tiago; Forjaz, Cláudia L. de Moraes; Low, David A.
2017-01-01
Post-exercise heart rate (HR) recovery (HRR) presents a biphasic pattern, which is mediated by parasympathetic reactivation and sympathetic withdrawal. Several mechanisms regulate these post-exercise autonomic responses and thermoregulation has been proposed to play an important role. The aim of this study was to test the effects of heat stress on HRR and HR variability (HRV) after aerobic exercise in healthy subjects. Twelve healthy males (25 ± 1 years, 23.8 ± 0.5 kg/m2) performed 14 min of moderate-intensity cycling exercise (40–60% HRreserve) followed by 5 min of loadless active recovery in two conditions: heat stress (HS) and normothermia (NT). In HS, subjects dressed in a whole-body water-perfused tube-lined suit to increase internal temperature (Tc) by ~1°C. In NT, subjects did not wear the suit. HR, core and skin temperatures (Tc and Tsk), mean arterial pressure (MAP) skin blood flow (SKBF), and cutaneous vascular conductance (CVC) were measured throughout and analyzed during post-exercise recovery. HRR was assessed through calculations of HR decay after 60 and 300 s of recovery (HRR60s and HRR300s), and the short- and long-term time constants of HRR (T30 and HRRt). Post-exercise HRV was examined via calculations of RMSSD (root mean square of successive RR intervals) and RMS (root mean square residual of RR intervals). The HS protocol promoted significant thermal stress and hemodynamic adjustments during the recovery (HS-NT differences: Tc = +0.7 ± 0.3°C; Tsk = +3.2 ± 1.5°C; MAP = −12 ± 14 mmHg; SKBF = +90 ± 80 a.u; CVC = +1.5 ± 1.3 a.u./mmHg). HRR and post-exercise HRV were significantly delayed in HS (e.g., HRR60s = 27 ± 9 vs. 44 ± 12 bpm, P < 0.01; HRR300s = 39 ± 12 vs. 59 ± 16 bpm, P < 0.01). The effects of heat stress (e.g., the HS-NT differences) on HRR were associated with its effects on thermal and hemodynamic responses. In conclusion, heat stress delays HRR, and this effect seems to be mediated by an attenuated parasympathetic reactivation and sympathetic withdrawal after exercise. In addition, the impact of heat stress on HRR is related to the magnitude of the heat stress-induced thermal stress and hemodynamic changes. PMID:29311799
Jay, Ollie; Reardon, Francis D; Webb, Paul; Ducharme, Michel B; Ramsay, Tim; Nettlefold, Lindsay; Kenny, Glen P
2007-08-01
Changes in mean body temperature (DeltaT(b)) estimated by the traditional two-compartment model of "core" and "shell" temperatures and an adjusted two-compartment model incorporating a correction factor were compared with values derived by whole body calorimetry. Sixty participants (31 men, 29 women) cycled at 40% of peak O(2) consumption for 60 or 90 min in the Snellen calorimeter at 24 or 30 degrees C. The core compartment was represented by esophageal, rectal (T(re)), and aural canal temperature, and the shell compartment was represented by a 12-point mean skin temperature (T(sk)). Using T(re) and conventional core-to-shell weightings (X) of 0.66, 0.79, and 0.90, mean DeltaT(b) estimation error (with 95% confidence interval limits in parentheses) for the traditional model was -95.2% (-83.0, -107.3) to -76.6% (-72.8, -80.5) after 10 min and -47.2% (-40.9, -53.5) to -22.6% (-14.5, -30.7) after 90 min. Using T(re), X = 0.80, and a correction factor (X(0)) of 0.40, mean DeltaT(b) estimation error for the adjusted model was +9.5% (+16.9, +2.1) to -0.3% (+11.9, -12.5) after 10 min and +15.0% (+27.2, +2.8) to -13.7% (-4.2, -23.3) after 90 min. Quadratic analyses of calorimetry DeltaT(b) data was subsequently used to derive best-fitting values of X for both models and X(0) for the adjusted model for each measure of core temperature. The most accurate model at any time point or condition only accounted for 20% of the variation observed in DeltaT(b) for the traditional model and 56% for the adjusted model. In conclusion, throughout exercise the estimation of DeltaT(b) using any measure of core temperature together with mean skin temperature irrespective of weighting is inaccurate even with a correction factor customized for the specific conditions.
Monticone, Marco; Ambrosini, Emilia; Rocca, Barbara; Foti, Calogero; Ferrante, Simona
2017-06-01
The Tampa Scale of Kinesiophobia (TSK) is a commonly-used measure for the assessment of fear of movement beliefs in chronic complaints, but its responsiveness in subjects after lumbar fusion has been never reported. Evaluating the responsiveness and minimal clinically important differences (MCIDs) for the TSK and its subscales after lumbar fusion. Population-based cohort study. Secondary care rehabilitation hospital. In-patients undergoing rehabilitation after lumbar fusion. At the beginning and end of a four-week motor and cognitive-behavioral rehabilitation program, 180 patients completed the TSK. After the intervention, the global perceived effect (GPE) was analyzed to produce a dichotomous outcome (improved vs. stable). Responsiveness for the TSK and its subscales were calculated by distribution (effect size [ES], standardized response mean [SRM]) and anchor-based methods (receiver operating characteristics (ROC) curves; correlations between change scores of the TSK and its subscales and GPE). ROC curves were also used to compute MCID values. The ES ranged from 1.63 to 1.77 and the SRM from 1.25 to 1.39 for TSK and its subscales. The ROC analyses revealed a value of area under the curve (0.999 [95% CI: 0.978; 1.000], 0.998 [95% CI: 0.975; 1.000], 0.990 [95% CI: 0.962; 0.999] for the TSK, Harm and Activity Avoidance subscales, respectively). MCID values greater than 6 (95% CI: >5; >6), 4 (95% CI: >3; >5), and 2 (95% CI: >2; >2) were achieved for the TSK, Harm and Activity Avoidance subscales, respectively. Correlations between change scores of the TSK and its subscales and GPE were high (0.786-0.830). The TSK and its subscales were sensitive in detecting clinical changes in subjects undergoing rehabilitation after lumbar fusion. The obtained MCID values will help in the design of future randomized controlled trials and in the interpretation of the clinical impact of a rehabilitation program after lumbar fusion.
Cardiovascular Drift during Training for Fitness in Patients with Metabolic Syndrome.
Morales-Palomo, Felix; Ramirez-Jimenez, Miguel; Ortega, Juan Fernando; Pallares, Jesus Garcia; Mora-Rodriguez, Ricardo
2017-03-01
The health benefits of a training program are largely influenced by the exercise dose and intensity. We sought to determine whether during a training bout of continuous versus interval exercise the workload needs to be reduced to maintain the prescribed target heart rate (HR). Fourteen obese (31 ± 4 kg·m) middle-age (57 ± 8 yr) individuals with metabolic syndrome, underwent two exercise training bouts matched by energy expenditure (i.e., 70 ± 5 min of continuous exercise [CE] or 45 min of interval exercise, high-intensity interval training [HIIT]). All subjects completed both trials in a randomized order. HR, power output (W), percent dehydration, intestinal and skin temperature (TINT and TSK), mean arterial pressure, cardiac output (CO), stroke volume (SV), and blood lactate concentration (La) were measured at the initial and latter stages of each trial to assess time-dependent drift. During the HIIT trial, power output was lowered by 30 ± 16 W to maintain the target HR, whereas a 10 ± 11 W reduction was needed in the CE trial (P < 0.05). Energy expenditure, CO, and SV declined with exercise time only in the HIIT trial (15%, 10%, and 13%, respectively). During HIIT, percent dehydration, TINT, and TSK increased more than during the CE trial (all P = 0.001). Mean arterial pressure and La were higher in HIIT without time drift in any trial. Our findings suggests that while CE results in mild power output reductions to maintain target HR, the increasingly popular HIIT results in marked reductions in power output, energy expenditure, and CO (21%, 15%, and 10%, respectively). HIIT based on target HR may result in lower than expected training adaptations because of workload adjustments to avoid HR drift.
Influence of environmental temperature on duathlon performance.
Sparks, S A; Cable, N T; Doran, D A; Maclaren, D P M
The aim of this study was to evaluate the physiological, metabolic and performance responses to duathlon performance under a range of ambient temperatures. Ten male recreational athletes performed three self-paced duathlon time trials consisting of a 5 km run (R1), a 30 km cycle and a 5 km run (R2) at 10 degrees C, 20 degrees C and 30 degrees C and a relative humidity of 50%. Performance times, heart rate (HR), rating of perceived exertion (RPE), core temperature (Tc) and skin temperature (Tsk) were measured every kilometre. Carbohydrate and fat oxidation rates were calculated via expired gas analysis at the first and fourth kilometres during both running stages. Blood samples were taken before and after exercise for the determination of prolactin concentration.Overall performance was significantly faster at 10 degrees C (100.76+/-5.32 min) than at 30 degrees C (105.38 +/- 4.28 min). Significantly higher Tc was noted in the 30 degrees C trial than in the 10 degrees C trial, with concomitant elevations in prolactin after exercise (19.88 +/- 6.48 ng/ml at 30 degrees C; 13.10 +/- 8.75 ng/ml at 10 degrees C). The rates of carbohydrate oxidation did not differ between conditions, although fat oxidation rates were highest at 10 degrees C. Elevated ambient temperature has a negative effect on duathlon performance. This effect may be reflected in increased Tc and prolactin concentration.
Postexercise Cooling Rates in 2 Cooling Jackets
Brade, Carly; Dawson, Brian; Wallman, Karen; Polglaze, Ted
2010-01-01
Abstract Context: Cooling jackets are a common method for removing stored heat accumulated during exercise. To date, the efficiency and practicality of different types of cooling jackets have received minimal investigation. Objective: To examine whether a cooling jacket containing a phase-change material (PC17) results in more rapid postexercise cooling than a gel cooling jacket and a no-jacket (control) condition. Design: Randomized, counterbalanced design with 3 experimental conditions. Setting: Participants exercised at 75% V̇o2max workload in a hot climate chamber (temperature = 35.0 ± 1.4°C, relative humidity = 52 ± 4%) for 30 minutes, followed by postexercise cooling for 30 minutes in cool laboratory conditions (ambient temperature = 24.9 ± 1.8°C, relative humidity = 39% ± 10%). Patients or Other Participants: Twelve physically active men (age = 21.3 ± 1.1 years, height = 182.7 ± 7.1 cm, body mass = 76.2 ± 9.5 kg, sum of 6 skinfolds = 50.5 ± 6.9 mm, body surface area = 1.98 ± 0.14 m2, V̇o2max = 49.0 ± 7.0 mL·kg−1·min−1) participated. Intervention(s): Three experimental conditions, consisting of a PC17 jacket, a gel jacket, and no jacket. Main Outcome Measure(s): Core temperature (TC), mean skin temperature (TSk), and TC cooling rate (°C/min). Results: Mean peak TC postexercise was 38.49 ± 0.42°C, 38.57 ± 0.41°C, and 38.55 ± 0.40°C for the PC17 jacket, gel jacket, and control conditions, respectively. No differences were observed in peak TC cooling rates among the PC17 jacket (0.038 ± 0.007°C/min), gel jacket (0.040 ± 0.009°C/min), and control (0.034 ± 0.010°C/min, P > .05) conditions. Between trials, no differences were calculated for mean TSk cooling. Conclusions: Similar cooling rates for all 3 conditions indicate that there is no benefit associated with wearing the PC17 or gel jacket. PMID:20210620
Cramer, Matthew N.; Gagnon, Daniel; Crandall, Craig G.; Jay, Ollie
2016-01-01
Attenuated skin blood flow (SkBF) is often assumed to impair core temperature (Tc) regulation. Profound pharmacologically-induced reductions in SkBF (~85%) lead to impaired sweating but whether the smaller attenuations in SkBF (~20%) more associated with ageing and certain diseases lead to decrements in sweating and maximum heat loss potential is unknown. Seven healthy males (28±4y) completed a 30-min equilibration period at 41°C and a vapour pressure (Pa) of 2.57 kPa followed by incremental steps in Pa of 0.17 kPa every 6-min to 5.95 kPa. Differences in heat loss potential were assessed by identifying the critical vapour pressure (Pcrit) at which an upward inflection in Tc occurred. Three separate treatments elicited changes in plasma volume to achieve three distinct levels of SkBF: control (CON), diuretic-induced iso-osmotic dehydration to lower SkBF (DEH), and continuous saline infusion to maintain SkBF (SAL). Tc, mean skin temperature (Tsk), heart rate, mean laser-Doppler flux (forearm, thigh; LDFmean), mean local sweat rate (forearm, thigh; LSRmean), and metabolic rate were measured. In DEH, a 14.2±5.7% lower plasma volume resulted in a ~20% lower LDFmean (DEH: 139±23, CON: 176±22, SAL: 186±22 PU; P=0.034). However, LSRmean and whole-body sweat losses were unaffected by treatment throughout (P>0.482). Pcrit for Tc was similar between treatments (CON: 5.05±0.30, DEH: 4.93±0.16, SAL: 5.12±0.10 kPa; P=0.166). Further, no differences were observed in the Tsk−Ta gradient, metabolic rate, or changes in Tc (P>0.197). In conclusion, a ~20% reduction in SkBF alters neither sweat rate nor the upper limit for heat loss from the skin during non-encapsulated passive heat stress. PMID:27859929
Takahashi, Takehiro; Asano, Yoshihide; Ichimura, Yohei; Toyama, Tetsuo; Taniguchi, Takashi; Noda, Shinji; Akamata, Kaname; Tada, Yayoi; Sugaya, Makoto; Kadono, Takafumi; Sato, Shinichi
2015-01-01
Bleomycin-induced fibrosis and the tight skin (TSK/+) mouse are well-established experimental murine models of human systemic sclerosis (SSc). Growing evidence has demonstrated the pivotal role of Toll-like receptors (TLRs) in several autoimmune inflammatory diseases, including SSc. This study was undertaken to determine the role of TLR-4 in the fibrotic processes in these murine models. We generated a murine model of bleomycin-induced SSc using TLR-4(-/-) mice and TLR-4(-/-) ;TSK/+ mice. The mechanisms by which TLR-4 contributes to pathologic tissue fibrosis were investigated in these 2 models by histologic examination, hydroxyproline assay, enzyme-linked immunosorbent assay, real-time polymerase chain reaction, and flow cytometry. Dermal and lung fibrosis was attenuated in bleomycin-treated TLR-4(-/-) mice compared with their wild-type counterparts. Inflammatory cell infiltration, expression of various inflammatory cytokines, and pathologic angiogenesis induced by bleomycin treatment were suppressed with TLR-4 deletion. Furthermore, the increased expression of interleukin-6 (IL-6) in fibroblasts, endothelial cells, and immune cells in response to bleomycin in vivo and to lipopolysaccharide in vitro was notably abrogated in the absence of TLR-4. Moreover, TLR-4 deletion was associated with alleviated B cell activation and skew toward a Th2/Th17 response against bleomycin treatment. Importantly, in TSK/+ mice, another SSc murine model, TLR-4 abrogation attenuated hypodermal fibrosis. These results indicate the pivotal contribution of TLR-4 to the pathologic tissue fibrosis of SSc murine models. Our results indicate the critical role of TLR-4 signaling in the development of tissue fibrosis, suggesting that biomolecular TLR-4 targeting might be a potential therapeutic approach to SSc. Copyright © 2015 by the American College of Rheumatology.
Jennings, John D.; Holowatz, Lacy A.; Kenney, W. Larry
2009-01-01
Primary human aging may be associated with augmented Rho kinase (ROCK)-mediated contraction of vascular smooth muscle and ROCK-mediated inhibition of nitric oxide synthase (NOS). We hypothesized that the contribution of ROCK to reflex vasoconstriction (VC) is greater in aged skin. Cutaneous VC was elicited by 1) whole body cooling [mean skin temperature (Tsk) = 30.5°C] and 2) local norepinephrine (NE) infusion (1 × 10−6 M). Four microdialysis fibers were placed in the forearm skin of eight young (Y) and eight older (O) subjects for infusion of 1) Ringer solution (control), 2) 3 mM fasudil (ROCK inhibition), 3) 20 mM NG-nitro-l-arginine methyl ester (NOS inhibition), and 4) both ROCK + NOS inhibitors. Red cell flux was measured by laser-Doppler flowmetry over each site. Cutaneous vascular conductance (CVC) was calculated as flux/mean arterial pressure and normalized to baseline CVC (%ΔCVCbaseline). VC was reduced at the control site in O during cooling (Y, −34 ± 3; and O, −18 ± 3%ΔCVCbaseline; P < 0.001) and NE infusion (Y, −53 ± 4, and O, −41 ± 9%ΔCVCbaseline; P = 0.006). Fasudil attenuated VC in both age groups during mild cooling; however, this reduction remained only in O but not in Y skin during moderate cooling (Y, −30 ± 5; and O, −7 ± 1%ΔCVCbaseline; P = 0.016) and was not altered by NOS inhibition. Fasudil blunted NE-mediated VC in both age groups (Y, −23 ± 4; and O, −7 ± 3%ΔCVCbaseline; P < 0.01). Cumulatively, these data indicate that reflex VC is more reliant on ROCK in aged skin such that approximately half of the total VC response to whole body cooling is ROCK dependent. PMID:19717729
Tsuji, Michio; Kume, Masashi; Tuneoka, Hideyuki; Yoshida, Tetsuya
2014-08-01
This study investigated whether wearing common white sportswear can reduce heat stress more than being semi-nude during exercise of different intensities performed under radiant heat and wind conditions, such as a hot summer day. After a 20-min rest period, eight male subjects performed three 20 min sessions of cycling exercise at a load intensity of 20 % or 50 % of their peak oxygen uptake (VO2peak) in a room maintained at a wet bulb globe temperature (WBGT) of 28.7 ± 0.1 °C using two spot lights and a fan (0.8 m/s airflow). Subjects wore common white sportswear (WS) consisting of a long-sleeved shirt (45 % cotton and 55 % polyester) and short pants (100 % polyester), or only swimming pants (SP) under the semi-nude condition. The mean skin temperature (Tsk) was greater when subjects wore SP than WS under both the 20 % and 50 % exercise conditions. During the 50 % exercise, the rating of perceived exertion (RPE) and thermal sensation (TS), and the increases in esophageal temperature (ΔTes) and heart rate were significantly higher (P<0.001-0.05), or tended to be higher (P<0.07), in the WS than SP trials at the end of the third 20-min exercise session. The total sweat loss (m sw,tot) was also significantly higher in the WS than in the SP trials (P<0.05). However, during the 20 % exercise, the m sw,tot during exercise, and the ΔTes, RPE and TS at the end of the second and third sessions of exercise did not differ significant between conditions. The heat storage (S), calculated from the changes in the mean body temperature (0.9Tes + 0.1 Tsk), was significantly lower in the WS trials than in the SP trials during the 20 min resting period before exercise session. However, S was similar between conditions during the 20 % exercise, but was greater in the WS than in the SP trials during 50 % exercise. These results suggest that, under conditions of radiant heat and wind at a WBGT greater than 28 °C, the heat stress associated with wearing common WS is similar to that of being semi-nude during light exercise, but was greater during moderate exercise, and the storage of body heat can be reduced by wearing WS during rest periods.
Koho, Petteri; Borodulin, Katja; Kautiainen, Hannu; Kujala, Urho; Pohjolainen, Timo; Hurri, Heikki
2015-03-01
To create reference values for the general Finnish population using the Tampa Scale of Kinesiophobia (TSK-FIN), to study gender differences in the TSK-FIN, to assess the internal consistency of the TSK-FIN, to estimate the prevalence of high levels of kinesiophobia in Finnish men and women, and to examine the association between kinesiophobia and leisure-time physical activity and the impact of co-morbidities on kinesiophobia. The study population comprised 455 men and 579 women. Participants completed a self-administered questionnaire about their socio-demographic factors, leisure-time physical activity, co-morbidities and kinesiophobia. The mean TSK-FIN score was significantly higher for men (mean 34.2, standard deviation (SD) 6.9) compared with women (mean 32.9, SD 6.5), with an age-adjusted p = 0.004 for the difference between men and women. Cronbach's alpha was 0.72, indicating substantial internal consistency. Men over 55 years of age and women over 65 years of age had a higher (p < 0.001) TSK score compared with younger people. There was a significant (p < 0.001) inverse association between kinesiophobia and leisure-time physical activity among both sexes. The presence of cardiovascular disease, musculoskeletal disease or a mental disorder was associated with a higher TSK-FIN score compared with the absence of the aforementioned disorders. We present here the reference values for the TSK-FIN. The reference values and prevalence among the general population may help clinicians to define the level of kinesiophobia among patients. Disorders other than musculoskeletal diseases were associated with kinesiophobia, which should be noted in daily practice.
Aguiar, A S; Bataglion, C; Visscher, C M; Bevilaqua Grossi, D; Chaves, T C
2017-07-01
Fear of movement (kinesiophobia) seems to play an important role in the development of chronic pain. However, for temporomandibular disorders (TMD), there is a scarcity of studies about this topic. The Tampa Scale for Kinesiophobia for TMD (TSK/TMD) is the most widely used instrument to measure fear of movement and it is not available in Brazilian Portuguese. The purpose of this study was to culturally adapt the TSK/TMD to Brazilian Portuguese and to assess its psychometric properties regarding internal consistency, reliability, and construct and structural validity. A total of 100 female patients with chronic TMD participated in the validation process of the TSK/TMD-Br. The intraclass correlation coefficient (ICC) was used for statistical analysis of reliability (test-retest), Cronbach's alpha for internal consistency, Spearman's rank correlation for construct validity and confirmatory factor analysis (CFA) for structural validity. CFA endorsed the pre-specified model with two domains and 12-items (Activity Avoidance - AA/Somatic Focus - SF) and all items obtained a loading factor greater than 0·4. Acceptable levels of reliability were found (ICC > 0·75) for all questions and domains of the TSK/TMD-Br. For internal consistency, Cronbach's α of 0·78 for both domains were found. Moderate correlations (0·40 < r < 0.60) were observed for 84% of the analyses conducted between TSK/TMD-Br scores versus catastrophising, depression and jaw functional limitation. TSK/TMD-Br 12 items and two-factor demonstrated sound psychometric properties (transcultural validity, reliability, internal consistency and structural validity). In such a way, the instrument can be used in clinical settings and for research purposes. © 2017 John Wiley & Sons Ltd.
Odaka, M; Hasegawa, M; Hamaguchi, Y; Ishiura, N; Kumada, S; Matsushita, T; Komura, K; Sato, S; Takehara, K; Fujimoto, M
2010-02-01
Studies have demonstrated that B cells play important roles in systemic sclerosis (SSc), especially through the CD19/CD22 autoimmune loop. CD22 is a B cell-specific inhibitory receptor that dampens B cell antigen receptor (BCR) signalling via tyrosine phosphorylation-dependent mechanism. In this study, we examined the presence and functional property of circulating autoantibodies reacting with CD22 in systemic sclerosis. Serum samples from 10 tight skin (TSK/+) mice and 50 SSc patients were assessed for anti-CD22 autoantibodies by enzyme-linked immunosorbent assays using recombinant mouse or human CD22. The association between anti-CD22 antibodies and clinical features was also investigated in SSc patients. Furthermore, the influence of SSc serum including anti-CD22 autoantibodies for CD22 tyrosine phosphorylation was examined by Western blotting using phosphotyrosine-specific antibodies reacting with four major tyrosine motifs of CD22 cytoplasmic domain. Anti-CD22 autoantibodies were positive in 80% of TSK/+ mice and in 22% of SSc patients. Patients positive for anti-CD22 antibodies showed significantly higher modified Rodnan skin thickness score compared with patients negative for anti-CD22 antibodies. Furthermore, anti-CD22 antibodies from patients' sera were capable of reducing phosphorylation of all four CD22 tyrosine motifs, while sera negative for anti-CD22 antibodies did not affect CD22 phosphorylation. Thus, a subset of SSc patients possessed autoantibodies reacting with a major inhibitory B cell response regulator, CD22. Because these antibodies can interfere CD22-mediated suppression onto B cell activation in vitro, SSc B cells produce functional autoantibodies that can enhance their own activation. This unique regulation may contribute to the autoimmune aspect of SSc.
Multiple Days of Heat Exposure on Firefighters' Work Performance and Physiology.
Larsen, Brianna; Snow, Rod; Vincent, Grace; Tran, Jacqueline; Wolkow, Alexander; Aisbett, Brad
2015-01-01
This study assessed the accumulated effect of ambient heat on the performance of, and physiological and perceptual responses to, intermittent, simulated wildfire fighting tasks over three consecutive days. Firefighters (n = 36) were matched and allocated to either the CON (19°C) or HOT (33°C) condition. They performed three days of intermittent, self-paced simulated firefighting work, interspersed with physiological testing. Task repetitions were counted (and converted to distance or area) to determine work performance. Participants were asked to rate their perceived exertion and thermal sensation after each task. Heart rate, core temperature (Tc), and skin temperature (Tsk) were recorded continuously throughout the simulation. Fluids were consumed ad libitum. Urine volume was measured throughout, and urine specific gravity (USG) analysed, to estimate hydration. All food and fluid consumption was recorded. There was no difference in work output between experimental conditions. However, significant variation in performance responses between individuals was observed. All measures of thermal stress were elevated in the HOT, with core and skin temperature reaching, on average, 0.24 ± 0.08°C and 2.81 ± 0.20°C higher than the CON group. Participants' doubled their fluid intake in the HOT condition, and this was reflected in the USG scores, where the HOT participants reported significantly lower values. Heart rate was comparable between conditions at nearly all time points, however the peak heart rate reached each circuit was 7 ± 3% higher in the CON trial. Likewise, RPE was slightly elevated in the CON trial for the majority of tasks. Participants' work output was comparable between the CON and HOT conditions, however the performance change over time varied significantly between individuals. It is likely that the increased fluid replacement in the heat, in concert with frequent rest breaks and task rotation, assisted with the regulation of physiological responses (e.g., heart rate, core temperature).
Multiple Days of Heat Exposure on Firefighters’ Work Performance and Physiology
Larsen, Brianna; Snow, Rod; Vincent, Grace; Tran, Jacqueline; Wolkow, Alexander; Aisbett, Brad
2015-01-01
This study assessed the accumulated effect of ambient heat on the performance of, and physiological and perceptual responses to, intermittent, simulated wildfire fighting tasks over three consecutive days. Firefighters (n = 36) were matched and allocated to either the CON (19°C) or HOT (33°C) condition. They performed three days of intermittent, self-paced simulated firefighting work, interspersed with physiological testing. Task repetitions were counted (and converted to distance or area) to determine work performance. Participants were asked to rate their perceived exertion and thermal sensation after each task. Heart rate, core temperature (Tc), and skin temperature (Tsk) were recorded continuously throughout the simulation. Fluids were consumed ad libitum. Urine volume was measured throughout, and urine specific gravity (USG) analysed, to estimate hydration. All food and fluid consumption was recorded. There was no difference in work output between experimental conditions. However, significant variation in performance responses between individuals was observed. All measures of thermal stress were elevated in the HOT, with core and skin temperature reaching, on average, 0.24 ± 0.08°C and 2.81 ± 0.20°C higher than the CON group. Participants’ doubled their fluid intake in the HOT condition, and this was reflected in the USG scores, where the HOT participants reported significantly lower values. Heart rate was comparable between conditions at nearly all time points, however the peak heart rate reached each circuit was 7 ± 3% higher in the CON trial. Likewise, RPE was slightly elevated in the CON trial for the majority of tasks. Participants’ work output was comparable between the CON and HOT conditions, however the performance change over time varied significantly between individuals. It is likely that the increased fluid replacement in the heat, in concert with frequent rest breaks and task rotation, assisted with the regulation of physiological responses (e.g., heart rate, core temperature). PMID:26379284
Coombs, G B; Cramer, M N; Ravanelli, N M; Morris, N B; Jay, O
2015-06-01
Acute acetaminophen (ACT) ingestion has been reported to reduce thermal strain during cycling in the heat. In this study, nine active participants ingested 20 mg of ACT per kg of total body mass (ACT) or a placebo (PLA), 60 min prior to cycling at a fixed rate of metabolic heat production (ACT: 8.3 ± 0.3 W/kg; PLA: 8.5 ± 0.5 W/kg), which was equivalent to 55 ± 6% VO2max , for 60 min at 34.5 ± 0.1 °C, 52 ± 1% relative humidity. Resting rectal temperature (Tre ; ACT: 36.70 ± 0.17 °C; PLA: 36.80 ± 0.16 °C, P = 0.24), esophageal temperature (Tes ; ACT: 36.54 ± 0.22 °C; PLA: 36.61 ± 0.17 °C, P = 0.50) and mean skin temperature (Tsk ; ACT: 34.00 ± 0.14 °C; PLA: 33.96 ± 0.20 °C, P = 0.70) were all similar among conditions. At end-exercise, no differences in ΔTre (ACT: 1.12 ± 0.15 °C; PLA: 1.11 ± 0.21 °C, P = 0.92), ΔTes (ACT: 0.90 ± 0.28 °C; PLA: 0.88 ± 0.23 °C, P = 0.84), ΔTsk (ACT: 0.80 ± 0.39 °C; PLA: 0.70 ± 0.46 °C, P = 0.63), mean local sweat rate (ACT: 1.02 ± 0.15 mg/cm(2) /min; PLA: 1.02 ± 0.13 mg/cm(2) /min, P = 0.98) and whole-body sweat loss (ACT: 663 ± 83 g; PLA: 663 ± 77 g, P = 0.995) were evident. Furthermore, ratings of perceived exertion and thermal sensation and thermal comfort were not different between ACT and PLA conditions. In conclusion, ACT ingested 60 min prior to moderate intensity exercise in hot-humid conditions does not alter physiologic thermoregulatory control nor perceived strain. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Influence of repeated daily menthol exposure on human temperature regulation and perception.
Gillis, D Jason; Weston, Neil; House, James R; Tipton, Michael J
2015-02-01
A single exposure to menthol can, depending on concentration, enhance both cool sensations and encourage body heat storage. This study tested whether there is an habituation in either response after repeated-daily exposures. Twenty-two participants were assigned to one of three spray groups: Control (CON; n=6), 0.05% L-menthol (M(0.05%); n=8), and 0.2% L-menthol (M(0.2%); n=8). On Monday (20°C, 50% rh) participants were sprayed with 100 mL of solution and undertook 40 min of cycling at 45% of their peak power (Ex1), from Tuesday to Thursday (30°C, 50% rh) they were sprayed twice daily whilst resting (R1 to R6), Friday was a repeat of Monday (Ex2). Thermal sensation (TS), thermal comfort, perceived exertion, irritation, rectal and skin temperature (Tsk), skin blood flow (SkBF) and sweat rate were monitored. A two-way ANOVA (alpha=0.05) compared responses from the beginning (Ex1, R1) and end (Ex2, R5) of the testing week. M(0.2%) induced significantly (P<0.05) cooler TS at the beginning of the week (Ex1, R1) compared to the end (Ex2, R5), indicating habituation of TS; this was not observed in M(0.05%). No other perceptual or physiological responses habituated. 0.2% Menthol caused a heat storage response, mediated by vasoconstriction, at the beginning and end of the week, suggesting the habituation of TS occurred in a pathway specific to sensation. In summary, the cooling influence of 0.2% menthol habituates after repeated-daily exposures, but with no habituation in heat storage. Copyright © 2014 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Yang, G.; Lin, Y.; Bhattacharya, P.
2007-12-01
To achieve an effective and safe operation on the machine system where the human interacts with the machine mutually, there is a need for the machine to understand the human state, especially cognitive state, when the human's operation task demands an intensive cognitive activity. Due to a well-known fact with the human being, a highly uncertain cognitive state and behavior as well as expressions or cues, the recent trend to infer the human state is to consider multimodality features of the human operator. In this paper, we present a method for multimodality inferring of human cognitive states by integrating neuro-fuzzy network and information fusion techniques. To demonstrate the effectiveness of this method, we take the driver fatigue detection as an example. The proposed method has, in particular, the following new features. First, human expressions are classified into four categories: (i) casual or contextual feature, (ii) contact feature, (iii) contactless feature, and (iv) performance feature. Second, the fuzzy neural network technique, in particular Takagi-Sugeno-Kang (TSK) model, is employed to cope with uncertain behaviors. Third, the sensor fusion technique, in particular ordered weighted aggregation (OWA), is integrated with the TSK model in such a way that cues are taken as inputs to the TSK model, and then the outputs of the TSK are fused by the OWA which gives outputs corresponding to particular cognitive states under interest (e.g., fatigue). We call this method TSK-OWA. Validation of the TSK-OWA, performed in the Northeastern University vehicle drive simulator, has shown that the proposed method is promising to be a general tool for human cognitive state inferring and a special tool for the driver fatigue detection.
Askary-Ashtiani, Ahmadreza; Ebrahimi-Takamejani, Ismail; Torkaman, Giti; Amiri, Mohsen; Mousavi, Seyed Javad
2014-08-15
Validation of 2 self-report questionnaires. To evaluate the internal consistency, reliability, and construct validity of the Persian versions of the fear avoidance beliefs questionnaire (FABQ) and the Tampa Scale of Kinesiophobia (TSK) in patients with acute and chronic neck pain. The FABQ and TSK are 2 important measures to evaluate fear of pain and fear avoidance beliefs in patients with spinal pain. To date, the psychometric properties of these questionnaires have not been demonstrated in Persian-speaking patients with neck pain in Iran. One hundred sixty-six patients with acute and chronic neck pain participated in the study. The construct validity of the questionnaires was evaluated by measuring convergent and known-groups validity. The visual analogue scale measure of pain, neck disability index, hospital anxiety and depression scale, and the physical (PCS-12) and mental (MCS-12) summary scores of the Short Form health survey (SF-12) were used to test construct validity of the Persian FABQ and TSK. In addition, 50 randomly selected patients with chronic neck pain were asked to complete the questionnaires 48 hours later for the second time. Cronbach α coefficient for the FABQ and TSK in patients with acute and chronic pain was in the range from 0.77 to 0.92 and 0.77 to 0.78, respectively. The Persian FABQ and TSK showed satisfactory test-retest reliability with intraclass correlation coefficient of more than 0.80. There were moderate to strong correlations between the Persian FABQ and TSK scores and the neck disability index (r = 0.44-0.55), Depression subscales of the hospital anxiety and depression scale (r = 0.42-0.48), and PCS-12 (r =-0.34 to -0.62). The Persian FABQ and TSK have acceptable reliability and validity for measuring pain related fear and avoidance beliefs among Persian-speaking patients with acute and chronic neck pain. However, considering the study limitations, the findings should be interpreted with caution. 3.
Multitask TSK fuzzy system modeling by mining intertask common hidden structure.
Jiang, Yizhang; Chung, Fu-Lai; Ishibuchi, Hisao; Deng, Zhaohong; Wang, Shitong
2015-03-01
The classical fuzzy system modeling methods implicitly assume data generated from a single task, which is essentially not in accordance with many practical scenarios where data can be acquired from the perspective of multiple tasks. Although one can build an individual fuzzy system model for each task, the result indeed tells us that the individual modeling approach will get poor generalization ability due to ignoring the intertask hidden correlation. In order to circumvent this shortcoming, we consider a general framework for preserving the independent information among different tasks and mining hidden correlation information among all tasks in multitask fuzzy modeling. In this framework, a low-dimensional subspace (structure) is assumed to be shared among all tasks and hence be the hidden correlation information among all tasks. Under this framework, a multitask Takagi-Sugeno-Kang (TSK) fuzzy system model called MTCS-TSK-FS (TSK-FS for multiple tasks with common hidden structure), based on the classical L2-norm TSK fuzzy system, is proposed in this paper. The proposed model can not only take advantage of independent sample information from the original space for each task, but also effectively use the intertask common hidden structure among multiple tasks to enhance the generalization performance of the built fuzzy systems. Experiments on synthetic and real-world datasets demonstrate the applicability and distinctive performance of the proposed multitask fuzzy system model in multitask regression learning scenarios.
Krieg, Thomas; Abraham, David; Lafyatis, Robert
2007-01-01
Fibrosis, characterized by excessive extracellular matrix accumulation, is a common feature of many connective tissue diseases, notably scleroderma (systemic sclerosis). Experimental studies suggest that a complex network of intercellular interactions involving endothelial cells, epithelial cells, fibroblasts and immune cells, using an array of molecular mediators, drives the pathogenic events that lead to fibrosis. Transforming growth factor-β and endothelin-1, which are part of a cytokine hierarchy with connective tissue growth factor, are key mediators of fibrogenesis and are primarily responsible for the differentiation of fibroblasts toward a myofibroblast phenotype. The tight skin mouse (Tsk-1) model of cutaneous fibrosis suggests that numerous other genes may also be important. PMID:17767742
Solar cycles and depositional processes in annual 10Be from two varved lake sediment records
NASA Astrophysics Data System (ADS)
Czymzik, Markus; Muscheler, Raimund; Brauer, Achim; Adolphi, Florian; Ott, Florian; Kienel, Ulrike; Dräger, Nadine; Słowiński, Michał; Aldahan, Ala; Possnert, Göran
2015-10-01
Beryllium 10 concentrations (10Becon) were measured at annual resolution from varved sediment cores of Lakes Tiefer See (TSK) and Czechowskie (JC) for the period 1983-2009 (∼solar cycles 22 and 23). Calibrating the 10Becon time-series against complementing proxy records from the same archive as well as local precipitation and neutron monitor data, reflecting solar forced changes in atmospheric radionuclide production, allowed (i) identifying the main depositional processes and (ii) evaluating the potential for solar activity reconstruction. 10Becon in TSK and JC sediments are significantly correlated to varying neutron monitor counts (TSK: r = 0.5, p = 0.05, n = 16; JC: r = 0.46, p = 0.03, n = 22). However, the further correlations with changes in organic carbon contents in TSK as well as varying organic carbon and detrital matter contents in JC point to catchment specific biases in the 10Becon time-series. In an attempt to correct for these biases multiple regression analysis was applied to extract an atmospheric 10Be production signal (10Beatmosphere). To increase the signal to noise ratio a 10Be composite record (10Becomposite) was calculated from the TSK and JC 10Beatmosphere time-series. 10Becomposite is significantly correlated to variations in the neutron monitor record (r = 0.49, p = 0.01, n = 25) and matches the expected amplitude changes in 10Be production between solar cycle minima and maxima. This calibration study on 10Be from two sites indicates the large potential but also, partly site-specific, limitations of 10Be in varved lake sediments for solar activity reconstruction.
Extracting TSK-type Neuro-Fuzzy model using the Hunting search algorithm
NASA Astrophysics Data System (ADS)
Bouzaida, Sana; Sakly, Anis; M'Sahli, Faouzi
2014-01-01
This paper proposes a Takagi-Sugeno-Kang (TSK) type Neuro-Fuzzy model tuned by a novel metaheuristic optimization algorithm called Hunting Search (HuS). The HuS algorithm is derived based on a model of group hunting of animals such as lions, wolves, and dolphins when looking for a prey. In this study, the structure and parameters of the fuzzy model are encoded into a particle. Thus, the optimal structure and parameters are achieved simultaneously. The proposed method was demonstrated through modeling and control problems, and the results have been compared with other optimization techniques. The comparisons indicate that the proposed method represents a powerful search approach and an effective optimization technique as it can extract the accurate TSK fuzzy model with an appropriate number of rules.
Physiological and perceptual effects of precooling in wheelchair basketball athletes
Pumpa, Kate; Knight, Emma; Miller, Joanna
2016-01-01
Objective To investigate the physiological and perceptual effects of three precooling strategies during pre-exercise rest in athletes with a spinal cord injury (SCI). Design Randomized, counterbalanced. Participants were precooled, then rested for 60 minutes (22.7 ± 0.2°C, 64.2 ± 2.6%RH). Setting National Wheelchair Basketball Training Centre, Australia. Participants Sixteen wheelchair basketball athletes with a SCI. Interventions Participants were precooled through; 1) 10 minutes of 15.8°C cold water immersion (CWI), 2) ingestion of 6.8 g/kg−1 of slushie (S) from sports drink; 3) ingestion of 6.8 g/kg−1 of slushie with application of iced towels to the legs, torso and back/arms (ST); or 4) ingestion of 6.8 g/kg−1 of room temperature (22.3°C) sports drink (CON). Outcome measures Core temperature (Tgi), skin temperature (Tsk), heart rate (HR), and thermal and gastrointestinal comfort. Results Following CWI, a significant reduction in Tgi was observed compared to CON, with a greatest reduction of 1.58°C occurring 40 minutes post-cooling (95% CI [1.07, 2.10]). A significant reduction in Tgi following ST compared to CON was also observed at 20 minutes (0.56°C; [0.03, 1.09]) and 30 minutes (0.56°C; [0.04, 1.09]) post-cooling. Additionally, a significant interaction between impairment level and time was observed for Tgi and HR, demonstrating athletes with a higher level of impairment experienced a greater reduction in HR and significant decrease in rate of decline in Tgi, compared to lesser impaired athletes. Conclusion CWI and ST can effectively lower body temperature in athletes with a SCI, and may assist in tolerating warm conditions. PMID:27192132
Adamczyk, Jakub Grzegorz; Krasowska, Ilona; Boguszewski, Dariusz; Reaburn, Peter
2016-08-01
Cold water immersion (CWI) and ice massage (IM) are commonly used treatments to prevent the delay onset of muscle soreness (DOMS); however, little is known on their relative benefits and effectiveness to lower tissue temperature. This study was designed to evaluate the effectiveness of IM and CMI on tissue temperature and potential benefit to preventing DOMS. The research encompassed 36 subjects divided into three groups of twelve depending on the form of recovery: ice massage (IM), cold-water immersion (CWI), or passive recovery (PAS). All the participants were asked to jump as high as possible from a full squat for one minute. Thermal imaging was conducted at rest, immediately following the exercise, immediately after the trial, following the recovery treatment, and after 30min of rest. Their pain levels were assessed using the Visual Analogue Scale (VAS). After applying the selected method for supporting recovery, the LA level decreased by 4.25mmol/L in the IM group, and by 4.96mmol/L in the CWI group (IM vs. CWI p>0.05). The 2.75mmol/L decrease in lactate concentration in the PAS group was significantly lower than in the other groups (IM vs. PAS p<0.05/ CWI vs. PAS p<0.01). In both groups, Tsk after 30min was significantly lower (ΔTsk~0.5°C) than at rest (p<0.05). In turn, Tsk in the PAS group returned to the resting values (p>0.05). Seventy-two hours after the exercise, a clear decrease in discomfort was observed in the IM and CWI groups compared to the PAS group. The two applied treatments have proven to be effective both in utilizing lactate and preventing DOMS. Depending on training requirements, we recommend the use of IM when athletes experience localized muscle fatigue. One the other hand, CWI is recommended in situations of global or generalized muscle injury or fatigue. Copyright © 2016 Elsevier Ltd. All rights reserved.
Chmielewski, Terese L; Jones, Debi; Day, Tim; Tillman, Susan M; Lentz, Trevor A; George, Steven Z
2008-12-01
Cross-sectional. To measure fear of movement/reinjury levels and determine the association with function at different timeframes during anterior cruciate ligament (ACL) reconstruction rehabilitation. We hypothesized that fear of movement/reinjury would decrease during rehabilitation and be inversely related with function. Fear of movement/reinjury can prevent return to sports after ACL reconstruction, but it has not been studied during rehabilitation. Demographic data and responses on the shortened version of Tampa Scale for Kinesiophobia (TSK-11), 8-Item Short-Form Health Survey (SF-8), and International Knee Documentation Committee (IKDC) subjective form were extracted from a clinical database for 97 patients in the first year after ACL reconstruction. Three groups were formed: group 1, less than or equal to 90 days; group 2, 91 to 180 days; group 3: 181 to 372 days post-ACL reconstruction. Group differences in TSK-11 score, SF-8 bodily pain rating, and IKDC scores were determined. Hierarchical linear regression models were created for each group, with IKDC score as the dependent variable and demographic factors, SF-8 bodily pain rating, and TSK-11 score as independent variables. TSK-11 score was higher in group 1 than in group 3 (P < .05). Across the groups, SF-8 bodily pain rating decreased (P < .001) and IKDC score increased (P < .001). SF-8 bodily pain rating was a significant factor in the regression model for all groups, whereas TSK-11 score only contributed to the regression model in group 3 (partial correlation, -0.529). Pain was consistently associated with function across the timeframes studied. Fear of movement/reinjury levels appear to decrease during ACL reconstruction rehabilitation and are associated with function in the timeframe when patients return to sports. Prognosis, level 4.
Perceptual responses while wearing an American football uniform in the heat.
Johnson, Evan C; Ganio, Matthew S; Lee, Elaine C; Lopez, Rebecca M; McDermott, Brendon P; Casa, Douglas J; Maresh, Carl M; Armstrong, Lawrence E
2010-01-01
The protective equipment worn during American football has been shown to increase thermal strain; however, the perception of this increased heat has not been examined. To evaluate perceptual responses of American football players while wearing different uniforms during exercise in the heat and to evaluate how these responses may be used to monitor athlete safety. Randomized controlled trial. Human Performance Laboratory. Ten men with more than 3 years of competitive experience as football linemen (age = 23.8 +/- 1.3 years, height = 183.9 +/- 1.8 cm, mass = 117.4 +/- 3.5 kg, body fat = 30.1% +/- 1.7%) participated. On 3 occasions in hot, humid (33 degrees C, 48%-49% relative humidity) environmental conditions, participants completed 10 minutes of strenuous repetitive box lifting (RBL), 10 minutes of seated rest, and up to 60 minutes of treadmill walking. At each trial, they wore a different uniform condition: control (CON) clothing comprising shorts, socks, and sneakers; partial (PART) National Football League (NFL) uniform comprising the uniform without helmet or shoulder pads; or full (FULL) NFL uniform. Exercise, meals, and hydration status were controlled. Rectal temperature (T(re)), skin temperature (T(sk)), rating of perceived exertion (RPE), thermal perception (THM), perception of thirst (TST), and perception of muscle pain (MPN) were obtained for time points matched across trials. Nineteen of the 30 trials ended before 60 minutes of treadmill walking as a result of participant exhaustion. Mean treadmill time was longer for the CON condition (51.7 +/- 13.4 minutes) than for the PART (43.1 +/- 15.6 minutes; t(9) = 3.092, P = .01) or the FULL (36.2 +/- 13.2 minutes; t(9) = 4.393, P = .002) conditions. Neck and forearm T(sk) increased between the initial time point and the end of exercise in the PART (33.6 +/- 0.9 degrees C and 35.0 +/- 0.6 degrees C, respectively; F(2,18) = 9.034, P < .001) and the FULL (33.4 +/- 0.9 degrees C and 35.2 +/- 0.6 degrees C, respectively; F(2,18) = 21.011, P = .002) conditions. Rate of T(re) rise was greater in the FULL (0.042 +/- 0.010 degrees C/min) than in the PART (0.034 +/- 0.006 degrees C/min) condition (F(2,27) = 10.69, P = .04). We found a relationship at the post-RBL and final time points between RPE and THM (r = 0.75, P < .001 and r = 0.59, P < .001, respectively), RPE and TST (r = 0.76, P < .001 and r = 0.61, P < .001, respectively), and RPE and MPN (r = 0.63, P < .001 and r = 0.64, P < .001, respectively). The RPE was greater at the end of exercise in the PART (17 +/- 2) and FULL (18 +/- 1) conditions than in the CON (15 +/- 3) condition (F(2,18) = 7.403, P = .005). Although no differences in perceptual scales existed between the PART and FULL conditions, the T(sk) and rate of T(re) increase differed, indicating that football athletes find it difficult to perceptually rate exercise conditions as potentially dangerous hyperthermia develops. In addition, correlations between the perceptual scales further defined perceptual responses during exercise in the heat.
Koho, P; Aho, S; Kautiainen, H; Pohjolainen, T; Hurri, H
2014-12-01
To estimate the internal consistency, test-retest reliability and comparability of paper and computer versions of the Finnish version of the Tampa Scale of Kinesiophobia (TSK-FIN) among patients with chronic pain. In addition, patients' personal experiences of completing both versions of the TSK-FIN and preferences between these two methods of data collection were studied. Test-retest reliability study. Paper and computer versions of the TSK-FIN were completed twice on two consecutive days. The sample comprised 94 consecutive patients with chronic musculoskeletal pain participating in a pain management or individual rehabilitation programme. The group rehabilitation design consisted of physical and functional exercises, evaluation of the social situation, psychological assessment of pain-related stress factors, and personal pain management training in order to regain overall function and mitigate the inconvenience of pain and fear-avoidance behaviour. The mean TSK-FIN score was 37.1 [standard deviation (SD) 8.1] for the computer version and 35.3 (SD 7.9) for the paper version. The mean difference between the two versions was 1.9 (95% confidence interval 0.8 to 2.9). Test-retest reliability was 0.89 for the paper version and 0.88 for the computer version. Internal consistency was considered to be good for both versions. The intraclass correlation coefficient for comparability was 0.77 (95% confidence interval 0.66 to 0.85), indicating substantial reliability between the two methods. Both versions of the TSK-FIN demonstrated substantial intertest reliability, good test-retest reliability, good internal consistency and acceptable limits of agreement, suggesting their suitability for clinical use. However, subjects tended to score higher when using the computer version. As such, in an ideal situation, data should be collected in a similar manner throughout the course of rehabilitation or clinical research. Copyright © 2014 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Thomas, J. C.; Cobbold, P. R.; Shein, V. S.; Le Douaran, S.
1999-11-01
The Turan and south Kazak domains (TSK) are in central Asia, between the Caspian Sea and the Tien Shan. The area is covered by sediments, deposited since the Late Permian during a series of tectonic events closely related to the history of two oceanic domains, Paleotethys and Neotethys. Sedimentary basins on the TSK therefore provide constraints on the tectonic development of the southern margin of Eurasia since the Late Permian. Our study is based on structure-contour maps and isopach maps of five key stratigraphic markers, of Late Permian to Tertiary age. Isopach maps help locate major faults and delimit sedimentary basins, providing information on vertical motions and, in some instances, horizontal motions. Subsidence associated with extension appears to have dominated the TSK, from the Late Permian to the Eocene. The extension may have been of back-arc type in southern Eurasia, next to the active margin, where the Paleotethys and Neotethys successively subducted toward the north. Here, sedimentary basins are both wide and deep (up to 15 km). During the Mesozoic, two compressional events of regional significance occurred in association with accretion of continental blocks at the southern margin of Eurasia. The first one, at the end of the Triassic, led to strong selective inversion of basins over the Turan domain. The second one, during the Late Jurassic-Early Cretaceous, had weaker effects. Since the Oligocene, following collision of both India and Arabia with Eurasia, inversion has become more generalized and compressional basins have formed on the TSK. Throughout the entire history of development of the TSK, from the Late Permian to the Tertiary, structures of Paleozoic and early Mesozoic age have exerted a strong control on sedimentation and especially on the location of depocenters. The south Kazak domain has registered little subsidence, in comparison with the Turan domain, where some basins have become very deep.
Moran, Robert W; Rushworth, Wendy M; Mason, Jesse
2017-12-01
Healthcare practitioner beliefs influence advice and management provided to patients with back pain. Several instruments measuring practitioner beliefs have been developed but psychometric properties for some have not been investigated. To investigate internal consistency, test-retest reliability and convergent validity of the Fear Avoidance Beliefs Tool (FABT), the Tampa Scale of Kinesiophobia for Health Care Providers (TSK-HC), the Back Pain Attitudes Questionnaire (Back-PAQ), and the Health Care Pain and Impairment Relationship Scale (HC-PAIRS). A secondary aim was to explore beliefs of New Zealand osteopaths and physiotherapists regarding low back pain. FABT, TSK-HC, Back-PAQ, and HC-PAIRS were administered twice, 14 days apart. Data from 91 osteopaths and 35 physiotherapists were analysed. The FABT, TSK-HC and Back-PAQ each demonstrated excellent internal consistency, (Cronbach's α = 0.92, 0.91, and 0.91 respectively), and excellent test-retest reliability (lower limit of 95% CI for intraclass correlation coefficient >0.75). Correlations between instruments (Pearson's r = 0.51 to 0.77, p < 0.001) demonstrated good convergent validity. There was a medium to large effect (Cohen's d > 0.47) for mean differences in scores, for all instruments, between professions. This study found excellent internal consistency, test-retest reliability and good convergent validity for the FABT, TSK-HC, and Back-PAQ. Previously reported internal consistency, test-retest and convergent validity of the HC-PAIRS were confirmed, and test-retest reliability was excellent. There were significant scoring differences on each instrument between professions, and while both groups demonstrated fear avoidant beliefs, physiotherapist respondent scores indicated that as a group, they held fewer fear-avoidant beliefs than osteopath respondents. Copyright © 2017 Elsevier Ltd. All rights reserved.
Flouris, Andreas D; Dinas, Petros C; Tsitoglou, Kiriakos; Patramani, Ioanna; Koutedakis, Yiannis; Kenny, Glen P
2015-07-01
We introduce a non-invasive and accurate method to assess tibialis anterior muscle temperature (Tm) during rest, cycling exercise, and post-exercise recovery using the insulation disk (INDISK) technique. Twenty-six healthy males (23.6 ± 6.2 years; 24.1 ± 3.1 body mass index) were randomly allocated into the 'model' (n = 16) and the 'validation' (n = 10) groups. Participants underwent 20 min supine rest, 20 min cycling exercise at 60% of age-predicted maximum heart rate, and 20 min supine post-exercise recovery. In the model group, Tm (34.55 ± 1.02 °C) was greater than INDISK temperature (Tid; 32.44 ± 1.23 °C; p < 0.001) and skin surface temperature (Tsk; 29.84 ± 1.47 °C; p < 0.001) throughout the experimental protocol. The strongest prediction model (R(2) = 0.646) incorporated Tid and the difference between the current Tid temperature and that recorded four minutes before. No mean difference (p > 0.05) and a strong correlation (r = 0.804; p < 0.001) were observed between Tm and predicted Tm (predTm) in the model group. Cross-validation analyses in the validation group demonstrated no mean difference (p > 0.05), a strong correlation (r = 0.644; p < 0.001), narrow 95% limits of agreement (-0.06 ± 1.51), and low percent coefficient of variation (2.24%) between Tm (34.39 ± 1.00 °C) and predTm (34.45 ± 0.73 °C). We conclude that the novel technique accurately predicts Tm during rest, cycling exercise, and post-exercise recovery, providing a valid and cost-efficient alternative when direct Tm measurement is not feasible.
Oostendorp, Rob A B; Elvers, Hans; Mikolajewska, Emilia; Laekeman, Marjan; Roussel, Nathalie; van der Zanden, Olaf; Nijs, Jo; Samwel, Han
2017-11-06
Manual physical therapists (MPTs) working in primary care get limited information about patient's courses of (chronic) low back pain (LBP). Identification of kinesiophobia is mostly based on clinical perception. The aim of this study was to evaluate the association between the scores with which manual physical therapists in a primary care setting identify kinesiophobia in patients with low back pain, and the patients' self-reported measures of kinesiophobia. The cross-sectional study comprised 104 patients with LBP and 17 MPTs. Patients first independently completed the Tampa Scale for Kinesiophobia (TSK-17). The therapists, blinded to the TSK-scores, rated their perception of a patient's kinesiophobia using the Visual Analogue Scale-Estimation (VAS-est) and the accuracy of their ratings using the Visual Analogue Scale-Accuracy (VAS-ac). Kendall's tau b was used to determine the level of correlation between scores on the TSK-17 and the VAS-est.
2014-07-01
onto an 8% SDS gel. Proteins were transferred to a polyvinylidene fluoride membrane, blocked in 5% nonfat milk in Tris-buffered saline, probed with...a)marker)of)fibrosis)[3,)4]),)we)assessed)both) protein )and)mRNA)levels)in)fibroblasts)that)received)DNA)from)a) plasmid)containing)a)single)allele...of)a)single)Col3a1%gene.)In)three)independent)experiments,)COL1A1) protein ) was)significantly)elevated)after)48)hours)of)transfection)with)Col3a1Tsk2
Mekjavic, Igor B; Golja, Petra; Tipton, Michael J; Eiken, Ola
2005-10-01
The present study evaluated the effect of 35 days of experimental horizontal bed-rest on exercise and immersion thermoregulatory function. Fifteen healthy male volunteers were assigned to either a Control (n = 5) or Bed-rest (n = 10) group. Thermoregulatory function was evaluated during a 30-min bout of submaximal exercise on a cycle ergometer, followed immediately by a 100-min immersion in 28 degrees C water. For the Bed-rest group, exercise and immersion thermoregulatory responses observed post-bed-rest were compared with those after a 5 week supervised active recovery period. In both trials, the absolute work load during the exercise portion of the test was identical. During the exercise and immersion, we recorded skin temperature, rectal temperature, the difference in temperature between the forearm and third digit of the right hand (DeltaT(forearm-fingertip))--an index of skin blood flow, sweating rate from the forehead, oxygen uptake and heart rate at minute intervals. Subjects provided ratings of temperature perception and thermal comfort at 5-min intervals. Exercise thermoregulatory responses after bed-rest and recovery were similar. Subjective ratings of temperature perception and thermal comfort during immersion indicated that subjects perceived similar combinations of Tsk and Tre to be warmer and thermally less uncomfortable after bed-rest. The average (SD) exercise-induced increase in Tre relative to resting values was not significantly different between the Post-bed-rest (0.4 (0.2) degrees C) and Recovery (0.5 (0.2) degrees C) trials. During the post-exercise immersion, the decrease in Tre, relative to resting values, was significantly (P < 0.05) greater in the Post-bed-rest trial (0.9 (0.5) degrees C) than after recovery (0.4 (0.3) degrees C). DeltaT(forearm-fingertip) was 5.2 (0.9) degrees C and 5.8 (1.0) degrees C at the end of the post-bed-rest and recovery immersions, respectively. The gain of the shivering response (increase in VO(2) relative to the decrease in Tre; VO(2)/Tre) was 1.19 l min(-1) degrees C(-1) in the Recovery trial, and was significantly attenuated to 0.51 l min(-1) degrees C(-1) in the Post-bed-rest trial. The greater cooling rate observed in the post-bed-rest trial is attributed to the greater heat loss and reduced heat production. The former is the result of attenuated cold-induced vasoconstriction and enhanced sweating rate, and the latter a result of a lower shivering VO(2) response.
Jiang, Yizhang; Wu, Dongrui; Deng, Zhaohong; Qian, Pengjiang; Wang, Jun; Wang, Guanjin; Chung, Fu-Lai; Choi, Kup-Sze; Wang, Shitong
2017-12-01
Recognition of epileptic seizures from offline EEG signals is very important in clinical diagnosis of epilepsy. Compared with manual labeling of EEG signals by doctors, machine learning approaches can be faster and more consistent. However, the classification accuracy is usually not satisfactory for two main reasons: the distributions of the data used for training and testing may be different, and the amount of training data may not be enough. In addition, most machine learning approaches generate black-box models that are difficult to interpret. In this paper, we integrate transductive transfer learning, semi-supervised learning and TSK fuzzy system to tackle these three problems. More specifically, we use transfer learning to reduce the discrepancy in data distribution between the training and testing data, employ semi-supervised learning to use the unlabeled testing data to remedy the shortage of training data, and adopt TSK fuzzy system to increase model interpretability. Two learning algorithms are proposed to train the system. Our experimental results show that the proposed approaches can achieve better performance than many state-of-the-art seizure classification algorithms.
Dietary nitrate reduces the O2 cost of desert marching but elevates the rise in core temperature.
Kuennen, Matthew; Jansen, Lisa; Gillum, Trevor; Granados, Jorge; Castillo, Weston; Nabiyar, Ahmad; Christmas, Kevin
2015-12-01
Dietary nitrate (NO3 (-)) supplementation reduces the O2 cost of fixed-workload tasks performed in temperate environments but has not been examined in the heat. If this effect were retained it could reduce heatstroke risk in military personnel that are deployed for desert combat. Nine men completed three 45 min loaded battle marches at a standard cadence (4.83 km h(-1)/1.5 % grade) while wearing full combat gear [BDU, boots, body armor (8 kg), NBC suit] and carrying a loaded rucksack (16 kg). The 1st March (FAM) commenced in a temperate environment. The 2nd and 3rd commenced in simulated dry desert conditions (41 °C/20 % RH) and required subjects to ingest the beetroot juice equivalent of 8.4 mmol NO3 (-) (BRJ) or a NO3 (-) depleted placebo (PLA) for 6 days prior. VO2, VCO2, V E, core (T re), skin (T sk), and mean body (T b) temperatures, HR, and physiological strain index (PSI) were measured continuously. Thermal sensation, generalized discomfort, and perceived exertion (RPE) were measured at 5 min intervals. Heat storage (HS) was calculated. Blood markers of gastrointestinal permeability (TNF, Il-6, HO-1) were measured before and after exercise. VO2 in BRJ was lower than PLA from 1 to 12; 16 to 26; and 29 to 45 min of exercise (p < 0.05). VCO2 in BRJ was lower than PLA from 1 to 12 min (p < 0.05). V E in BRJ was lower than PLA from 1 to 20 min of exercise (p < 0.05). T re and T b in BRJ exceeded PLA from 16 to 45 min (p < 0.05). TNF, Il-6, and HO-1 were reduced in BRJ (p < 0.05) while HR, PSI, Tsk, and HS were not altered (p > 0.05). Thermal sensation, generalized discomfort, and RPE were elevated in BRJ from 40 to 45, 25 to 45, and 10 to 45 min, respectively (p < 0.01). Metabolic efficiency was improved in BRJ. Paradoxically, body temperatures rose more. This was not due to gut permeability. Therefore, we speculate that based on elimination of other possibilities, blood redistribution from skin to skeletal muscle may have contributed to impaired heat exchange.
Environmental Mycobiome Modifiers of Inflammation and Fibrosis in Systemic Sclerosis
2015-09-01
deleterious compared with a complete genetic deficiency of COL3A1. Col3a1Tsk2 induces increased COL1A1 and ECM production in vitro Because the...Col3a1-KO/KO homozygote at birth. Using the production of COL1A1 as a measure of fibrosis 800 600 400 200 100 50 W T ( 10 ) W T ( 12 ) T sk 2...independent experiments, COL1A1 protein was significantly elevated after 48 hours of transfection with Col3a1Tsk2 relative to transfection with Col3a1WT
A three-compartment thermometry model for the improved estimation of changes in body heat content.
Jay, Ollie; Gariépy, Louise M; Reardon, Francis D; Webb, Paul; Ducharme, Michel B; Ramsay, Tim; Kenny, Glen P
2007-01-01
The aim of this study was to use whole body calorimetry to directly measure the change in body heat content (DeltaH(b)) during steady-state exercise and compare these values with those estimated using thermometry. The thermometry models tested were the traditional two-compartment model of "core" and "shell" temperatures, and a three-compartment model of "core," "muscle," and "shell" temperatures; with individual compartments within each model weighted for their relative influence upon DeltaH(b) by coefficients subject to a nonnegative and a sum-to-one constraint. Fifty-two participants performed 90 min of moderate-intensity exercise (40% of Vo(2 peak)) on a cycle ergometer in the Snellen air calorimeter, at regulated air temperatures of 24 degrees C or 30 degrees C and a relative humidity of either 30% or 60%. The "core" compartment was represented by temperatures measured in the esophagus (T(es)), rectum (T(re)), and aural canal (T(au)), while the "muscle" compartment was represented by regional muscle temperature measured in the vastus lateralis (T(vl)), triceps brachii (T(tb)), and upper trapezius (T(ut)). The "shell" compartment was represented by the weighted mean of 12 skin temperatures (T(sk)). The whole body calorimetry data were used to derive optimally fitting two- and three-compartment thermometry models. The traditional two-compartment model was found to be statistically biased, systematically underestimating DeltaH(b) by 15.5% (SD 31.3) at 24 degrees C and by 35.5% (SD 21.9) at 30 degrees C. The three-compartment model showed no such bias, yielding a more precise estimate of DeltaH(b) as evidenced by a mean estimation error of 1.1% (SD 29.5) at 24 degrees C and 5.4% (SD 30.0) at 30 degrees C with an adjusted R(2) of 0.48 and 0.51, respectively. It is concluded that a major source of error in the estimation of DeltaH(b) using the traditional two-compartment thermometry model is the lack of an expression independently representing the heat storage in muscle during exercise.
Kinesiophobia and Its Association With Health-Related Quality of Life Across Injury Locations.
Goldberg, Penny; Zeppieri, Giorgio; Bialosky, Joel; Bocchino, Charlotte; van den Boogaard, Jon; Tillman, Susan; Chmielewski, Terese L
2018-01-01
To compare baseline kinesiophobia levels and their association with health-related quality of life across injury locations. Retrospective cross-sectional study. Single, large outpatient physical therapy clinic within an academic medical center. Patients (N=1233) who underwent an initial evaluation for a diagnosis related to musculoskeletal pain and completed the 11-item version of the Tampa Scale for Kinesiophobia (TSK-11) and the Medical Outcomes Study 8-Item Short-Form Health Survey (SF-8) questionnaires within 7 days of their first visit were eligible for inclusion. Three hundred eighty patients were excluded because of missing data or because they were younger than 18 years. A total of 853 patients (mean age, 43.55y; range, 18-94y) were included. Not applicable. Comparison of baseline kinesiophobia levels and their association with health-related quality of life across injury locations in an outpatient physical therapy setting. Separate analysis of variance models compared TSK-11 scores based on involved body region, and Pearson correlation coefficients were used to examine the association between TSK-11 scores and the SF-8 subscales at each body region. TSK-11 scores did not differ by body region (range, 23.9-26.1). Weak to moderate negative correlations existed between kinesiophobia and the SF-8 subscales. Kinesiophobia levels appear elevated and negatively associated with health-related quality of life at initial physical therapy evaluation regardless of injury location. These findings suggest that physical therapists in outpatient orthopedic settings should implement routine kinesiophobia assessment and provide stratified care based on kinesiophobia levels across musculoskeletal conditions. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Calley, Darren Q; Jackson, Steven; Collins, Heather; George, Steven Z
2010-12-01
Cross-sectional. To evaluate the accuracy with which physical therapists identify fear-avoidance beliefs in patients with low back pain by comparing therapist ratings of perceived patient fear-avoidance to the Fear-Avoidance Beliefs Questionnaire (FABQ), Tampa Scale of Kinesiophobia 11-item (TSK-11), and Pain Catastrophizing Scale (PCS). To compare the concurrent validity of therapist ratings of perceived patient fear-avoidance and a 2-item questionnaire on fear of physical activity and harm, with clinical measures of fear-avoidance (FABQ, TSK-11, PCS), pain intensity as assessed with a numeric pain rating scale (NPRS), and disability as assessed with the Oswestry Disability Questionnaire (ODQ). The need to consider psychosocial factors for identifying patients at risk for disability and chronic low back pain has been well documented. Yet the ability of physical therapists to identify fear-avoidance beliefs using direct observation has not been studied. Eight physical therapists and 80 patients with low back pain from 3 physical therapy clinics participated in the study. Patients completed the FABQ, TSK-11, PCS, ODQ, NPRS, and a dichotomous 2-item fear-avoidance screening questionnaire. Following the initial evaluation, physical therapists rated perceived patient fear-avoidance on a 0-to-10 scale and recorded 2 influences on their ratings. Spearman correlation and independent t tests determined the level of association of therapist 0-to-10 ratings and 2-item screening with fear-avoidance and clinical measures. Therapist ratings of perceived patient fear-avoidance had fair to moderate interrater reliability (ICC2,1 = 0.663). Therapist ratings did not strongly correlate with FABQ or TSK-11 scores. Instead, they unexpectedly had stronger associations with ODQ and PCS scores. Both 2-item screening questions were associated with FABQ-physical activity scores, while the fear of physical activity question was also associated with FABQ-work, TSK-11, PCS, and ODQ scores. Therapists' ratings of perceived patient fear-avoidance were not associated with self-reported fear-avoidance scores, showing a potential disconnect between therapist judgments and commonly used fear-avoidance measures. Instead, therapist ratings had small but statistically significant correlations with pain catastrophizing and disability, findings that may support therapists' inability to discriminate fear-avoidance from these other factors. The 2-item screening questions based on fear of physical activity and harm showed potential to identify elevated FABQ physical activity scores. Differential diagnosis, level 2b.
Paterno, Mark V; Flynn, Kaitlyn; Thomas, Staci; Schmitt, Laura C
Outcomes after anterior cruciate ligament reconstruction (ACLR) are highly variable. Previous studies have failed to report the relationship between fear, objective measures of function, and reinjury rates. The purpose of this study was to determine whether fear was related to functional performance measures and risk of second ACL injury after ACLR and return to sport (RTS). Fear will be associated with performance on functional testing and second ACL injury rate. Prospective cohort study. Level 2. A total of 40 patients cleared to RTS after ACLR completed the Tampa Scale of Kinesiophobia (TSK-11), hop testing, and quadriceps strength testing, bilaterally. Patients were tracked for 12 months after RTS to identify the incidence of second ACL injury. Chi-square analyses determined whether patients with high fear (TSK-11, ≥17) were more likely to have lower levels of activity, greater asymmetry on functional testing, and higher reinjury rates. Patients with greater fear on the TSK-11 (≥17) at RTS were 4 times (odds ratio [OR], 3.73; 95% CI, 0.98-14.23) more likely to report lower levels of activity, 7 times (OR, 7.1; 95% CI, 1.5-33.0) more likely to have a hop limb symmetry lower than 95%, and 6 times (OR, 6.0; 95% CI, 1.3-27.8) more likely to have quadriceps strength symmetry lower than 90%. Patients who went on to suffer an ipsilateral second ACL injury had a greater TSK-11 score at the time of RTS (mean, 19.8 ± 4.0) than those who did not suffer a second ACL injury (mean, 16.4 ± 3.6) ( P = 0.03). Patients with a TSK-11 score of 19 or greater at the time of RTS were 13 times (relative risk, 13.0; 95% CI, 2.1-81.0) more likely to suffer a second ACL tear within 24 months after RTS. Patients with greater self-reported fear were less active, presented with lower single-leg hop performance and isometric quadriceps strength, and had an increased risk of suffering a second ACL injury in the 24 months after RTS. Self-reported fear of movement/reinjury after ACLR at the time of RTS may be an important measure to incorporate into discharge criteria prior to release to return to pivoting and cutting sports after ACLR.
El-Nagar, Ahmad M
2018-01-01
In this study, a novel structure of a recurrent interval type-2 Takagi-Sugeno-Kang (TSK) fuzzy neural network (FNN) is introduced for nonlinear dynamic and time-varying systems identification. It combines the type-2 fuzzy sets (T2FSs) and a recurrent FNN to avoid the data uncertainties. The fuzzy firing strengths in the proposed structure are returned to the network input as internal variables. The interval type-2 fuzzy sets (IT2FSs) is used to describe the antecedent part for each rule while the consequent part is a TSK-type, which is a linear function of the internal variables and the external inputs with interval weights. All the type-2 fuzzy rules for the proposed RIT2TSKFNN are learned on-line based on structure and parameter learning, which are performed using the type-2 fuzzy clustering. The antecedent and consequent parameters of the proposed RIT2TSKFNN are updated based on the Lyapunov function to achieve network stability. The obtained results indicate that our proposed network has a small root mean square error (RMSE) and a small integral of square error (ISE) with a small number of rules and a small computation time compared with other type-2 FNNs. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.
Genetic reinforcement learning through symbiotic evolution for fuzzy controller design.
Juang, C F; Lin, J Y; Lin, C T
2000-01-01
An efficient genetic reinforcement learning algorithm for designing fuzzy controllers is proposed in this paper. The genetic algorithm (GA) adopted in this paper is based upon symbiotic evolution which, when applied to fuzzy controller design, complements the local mapping property of a fuzzy rule. Using this Symbiotic-Evolution-based Fuzzy Controller (SEFC) design method, the number of control trials, as well as consumed CPU time, are considerably reduced when compared to traditional GA-based fuzzy controller design methods and other types of genetic reinforcement learning schemes. Moreover, unlike traditional fuzzy controllers, which partition the input space into a grid, SEFC partitions the input space in a flexible way, thus creating fewer fuzzy rules. In SEFC, different types of fuzzy rules whose consequent parts are singletons, fuzzy sets, or linear equations (TSK-type fuzzy rules) are allowed. Further, the free parameters (e.g., centers and widths of membership functions) and fuzzy rules are all tuned automatically. For the TSK-type fuzzy rule especially, which put the proposed learning algorithm in use, only the significant input variables are selected to participate in the consequent of a rule. The proposed SEFC design method has been applied to different simulated control problems, including the cart-pole balancing system, a magnetic levitation system, and a water bath temperature control system. The proposed SEFC has been verified to be efficient and superior from these control problems, and from comparisons with some traditional GA-based fuzzy systems.
Vincent, Heather K; Lamb, Kelley M; Day, Tim I; Tillman, Susan M; Vincent, Kevin R; George, Steven Z
2010-08-01
To compare fear of movement in patients with different body mass index (BMI) values referred for rehabilitative care of the knee and to examine whether this fear contributed to self-reported knee-related function. We hypothesized that fear of movement would be elevated with increasing BMI and that fear would correspond with lower self-report knee-related function and lower quality of life (QOL). Retrospective cross-sectional study. Outpatient therapy clinic affiliated with a tertiary care hospital. Patients with knee pain diagnoses (n = 278) were stratified into 4 BMI groups (in < or =25 kg/m(2) nonobese; 25-29.9 kg/m(2) overweight; 30-39.9 kg/m(2) obese; > or =40 kg/m(2) morbidly obese). The Tampa Scale of Kinesiophobia (TSK; fear of movement), International Knee Documentation (IKDC; knee function), and Short-Form 8 (SF-8; QOL) scores were main outcomes. Pain and straight leg raise test scores also were collected. After review of the medical records, descriptive statistics and nonparametric tests were performed, and TSK, QOL, and SF-8 scores were compared. Hierarchical regression modeling determined the contribution of TSK scores to the variance of IKDC scores. Pain scores were greatest in the nonobese group and lowest in the morbidly obese group (7.5 +/- 2.6 points vs 4.8 +/- 3.1 points; P < .05). TSK scores in morbidly obese patients were greater than in nonobese patients (27.1 +/- 7.7 points vs 22.0 +/- 6.6 points; P = .002). The SF-8 mental-physical subscores were 27% to 32% lower in the morbidly obese than nonobese patients (both P < .0001). IKDC scores were lower in the morbidly obese than nonobese patients (32.1 +/- 19.2 points vs 50.9 +/- 23.8 points; P = .0001). Pain severity and TSK scores contributed 28.6% and 7.1% to the variance of the IKDC scores (overall R(2) = 68.6). Morbid obesity is associated with elevated fear of movement. Pain was the strongest predictor of IKDC scores, and fear of movement enhanced this predictive value of the regression model. Despite lower absolute pain severity in the morbidly obese group, this fear may influence IKDC scores in this population. Morbidly obese patients might benefit from rehabilitation activities that reduce fear of movement to optimize participation in rehabilitation activity. Copyright © 2010 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.
The effects of solar radiation on thermal comfort.
Hodder, Simon G; Parsons, Ken
2007-01-01
The aim of this study was to investigate the relationship between simulated solar radiation and thermal comfort. Three studies investigated the effects of (1) the intensity of direct simulated solar radiation, (2) spectral content of simulated solar radiation and (3) glazing type on human thermal sensation responses. Eight male subjects were exposed in each of the three studies. In Study 1, subjects were exposed to four levels of simulated solar radiation: 0, 200, 400 and 600 Wm(-2). In Study 2, subjects were exposed to simulated solar radiation with four different spectral contents, each with a total intensity of 400 Wm(-2) on the subject. In Study 3, subjects were exposed through glass to radiation caused by 1,000 Wm(-2) of simulated solar radiation on the exterior surface of four different glazing types. The environment was otherwise thermally neutral where there was no direct radiation, predicted mean vote (PMV)=0+/-0.5, [International Standards Organisation (ISO) standard 7730]. Ratings of thermal sensation, comfort, stickiness and preference and measures of mean skin temperature (t(sk)) were taken. Increase in the total intensity of simulated solar radiation rather than the specific wavelength of the radiation is the critical factor affecting thermal comfort. Thermal sensation votes showed that there was a sensation scale increase of 1 scale unit for each increase of direct radiation of around 200 Wm(-2). The specific spectral content of the radiation has no direct effect on thermal sensation. The results contribute to models for determining the effects of solar radiation on thermal comfort in vehicles, buildings and outdoors.
Sugeno-Fuzzy Expert System Modeling for Quality Prediction of Non-Contact Machining Process
NASA Astrophysics Data System (ADS)
Sivaraos; Khalim, A. Z.; Salleh, M. S.; Sivakumar, D.; Kadirgama, K.
2018-03-01
Modeling can be categorised into four main domains: prediction, optimisation, estimation and calibration. In this paper, the Takagi-Sugeno-Kang (TSK) fuzzy logic method is examined as a prediction modelling method to investigate the taper quality of laser lathing, which seeks to replace traditional lathe machines with 3D laser lathing in order to achieve the desired cylindrical shape of stock materials. Three design parameters were selected: feed rate, cutting speed and depth of cut. A total of twenty-four experiments were conducted with eight sequential runs and replicated three times. The results were found to be 99% of accuracy rate of the TSK fuzzy predictive model, which suggests that the model is a suitable and practical method for non-linear laser lathing process.
Heat stress and a countermeasure in the Shuttle rescueman's suit
NASA Technical Reports Server (NTRS)
Doerr, D. F.; Reed, H.; Convertino, V. A.
1992-01-01
Rescue of the astronaut flight crew from a contingency landing may risk exposure of the rescue crew to toxic propellants spilling from potentially ruptured tanks in the crew module area. An Aquala dry diver's suit has been in service by the rescue team to preclude exposure, especially in the water rescue scenario. Heat stress has become a factor of concern in recent years when older and less physically-fit team members work in this suit. Methods: Field testing was initiated using fully instrumented rescue men in a simulated scenario to determine the extent of heat stress. Two tests were accomplished, one in the normal (N) configuration and one with a proposed cooling countermeasure, the Steele vest (S). Results: Heat stress was high as indicated by average rectal temperatures (Tre) of 38.28 degrees C(100.9 degrees F) after the 45 minute protocol. Slopes of the regression equations describing the increase in Tre with time were greater (P less than 0.05) with N (0.073 plus or minus .008) compared to S (0.060 plus or minus .007). Projection of time to the 38.89 degree C (102 degree F) limit was increased by 15.3 percent with the vest. Mean skin temperature (Tsk) was higher (P less than 0.05) in N (38.33 plus or minus .11 degrees C) compared to S (34.33 plus or minus .39 degrees C). Average heart rate was higher (P less than 0.05 in N than S. Sweat loss, as measured by weight loss, was more (P less than 0.05) for N (1.09 plus or minus .09 kg versus 0.77 plus or minus .06 kg). Air usage, while slightly less for S, was not statistically different. Conclusion: The use of the cool vest provided significant relief from thermal stress in spite of the addition of 3.4 kg (7.5 pounds) weight and some loss in mobility.
High skin temperature and hypohydration impair aerobic performance.
Sawka, Michael N; Cheuvront, Samuel N; Kenefick, Robert W
2012-03-01
This paper reviews the roles of hot skin (>35°C) and body water deficits (>2% body mass; hypohydration) in impairing submaximal aerobic performance. Hot skin is associated with high skin blood flow requirements and hypohydration is associated with reduced cardiac filling, both of which act to reduce aerobic reserve. In euhydrated subjects, hot skin alone (with a modest core temperature elevation) impairs submaximal aerobic performance. Conversely, aerobic performance is sustained with core temperatures >40°C if skin temperatures are cool-warm when euhydrated. No study has demonstrated that high core temperature (∼40°C) alone, without coexisting hot skin, will impair aerobic performance. In hypohydrated subjects, aerobic performance begins to be impaired when skin temperatures exceed 27°C, and even warmer skin exacerbates the aerobic performance impairment (-1.5% for each 1°C skin temperature). We conclude that hot skin (high skin blood flow requirements from narrow skin temperature to core temperature gradients), not high core temperature, is the 'primary' factor impairing aerobic exercise performance when euhydrated and that hypohydration exacerbates this effect.
Schafer, Dorothea; Boogaart, Sheri; Johnson, Lynette; Keezel, Catherine; Ruperts, Liga; Vander Laan, Karen J
2014-02-01
Appropriate thermoregulation affects both morbidity and mortality in the neonatal setting. Nurses rely on information from temperature sensors and radiant warmers or incubators to appropriately maintain a neonate's body temperature. Skin temperature sensors must be repositioned to prevent skin irritation and breakdown. This study addresses whether there is a significant difference between skin sensor temperature readings from 3 locations on the neonate and whether there is a significant difference between skin sensor temperatures compared with digital axillary temperatures. The study participants included 36 hemodynamically stable neonates, with birth weight of 750 g or more and postnatal age of 15 days or more, in a neonatal intensive care unit. Gestational age ranged from 29.6 to 36.1 weeks at the time of data collection. A method-comparison design was used to evaluate the level of agreement between skin sensor temperatures and digital axillary thermometer measurements. When the neonate's skin sensor was scheduled for routine site change, 3 new skin sensors were placed-1 each on the right upper abdomen, left flank, and right axilla. The neonate was placed in a supine position and redressed or rewrapped if previously dressed or wrapped. Subjects served as their own controls, with temperatures measured at all 3 skin sensor sites and followed by a digital thermometer measurement in the left axilla. The order of skin sensor temperature measurements was randomly assigned by a computer-generated number sequence. An analysis of variance for repeated measures was used to test for statistical differences between the skin sensor temperatures. The difference in axillary and skin sensor temperatures was calculated by subtracting the reference standard temperature (digital axillary) from the test temperatures (skin temperatures at 3 different locations), using the Bland-Altman method. The level of significance was set at P < .05. No statistically significant differences were found between skin temperature readings obtained from the 3 sites (F2,70 = 2.993, P = .57). Differences between skin temperature readings and digital axillary temperature were also not significant when Bland-Altman graphs were plotted. For hemodynamically stable neonates in a supine position, there were no significant differences between skin sensor temperatures on abdomen, flank, or axilla or between skin sensor temperatures and a digital axillary temperature. This may increase nurses' confidence that various sites will produce accurate temperature readings.
Matseliukh, O V; Nidialkova, N A; Varbanets', L D
2012-01-01
The scheme of isolation and purification of Bacillus thuringiensis IMV B-7324 peptidase has been developed. This scheme includes ammonium sulfate precipitation and chromatography on neutral and charged TSK-gels. It was found that the enzyme hydrolyzes elastin and fibrin. The molecular weight is 26 kDa. It was shown that the enzyme is an alkaline serine peptidase. The optimal pH of hydrolysis of elastin and fibrin were 9.0 and 10.0, respectively. The optimal temperature of elastin and fibrin hydrolysis are 40 and 50 degrees C, respectively. The high stability of the purified preparation in the studied range of pH and temperature was shown. The stabilizing effect of zinc at a concentration of 1 mM on the elastase activity, and the inhibitory effect of other divalent cations under study have been established. The investigated chloride and acetate anions reduced activity by 20%, while phosphate anions increased activity by 15-30%.
Multi Groups Cooperation based Symbiotic Evolution for TSK-type Neuro-Fuzzy Systems Design
Cheng, Yi-Chang; Hsu, Yung-Chi
2010-01-01
In this paper, a TSK-type neuro-fuzzy system with multi groups cooperation based symbiotic evolution method (TNFS-MGCSE) is proposed. The TNFS-MGCSE is developed from symbiotic evolution. The symbiotic evolution is different from traditional GAs (genetic algorithms) that each chromosome in symbiotic evolution represents a rule of fuzzy model. The MGCSE is different from the traditional symbiotic evolution; with a population in MGCSE is divided to several groups. Each group formed by a set of chromosomes represents a fuzzy rule and cooperate with other groups to generate the better chromosomes by using the proposed cooperation based crossover strategy (CCS). In this paper, the proposed TNFS-MGCSE is used to evaluate by numerical examples (Mackey-Glass chaotic time series and sunspot number forecasting). The performance of the TNFS-MGCSE achieves excellently with other existing models in the simulations. PMID:21709856
Knox, D M
1999-06-01
To ascertain the effects of 1-, 1 1/2-, and 2-hour turning intervals on nursing home residents' skin over the sacrum and trochanters. (1) the higher the core body temperature, the higher the skin surface temperature; (2) the 2-hour turning interval would have significantly higher skin surface temperature; (3) there would be no relationship between skin surface temperature and interface pressure; and (4) the sacrum would have the lowest skin surface temperature. Modified Latin-square. For-profit nursing home. Convenience sample of 26 residents who scored < 3 on the Short Portable Mini-Mental Status Questionnaire and did not have (1) open wounds; (2) albumin levels < 3.3 mg/dL; (3) severe arthritis; (4) cortisone, anticoagulation, insulin therapy or 3 medications for hypertension; and/or (5) were totally bedridden. First Temp measured core temperature; a disposable thermistor temperature probe, skin temperature; and a digital interface pressure evaluator, the interface pressure. Negative correlation (r = -.33, P = .003) occurred between core body temperature and skin surface temperature. Skin surface temperature rose at the end of the 2-hour turning interval but was not significant (F = (2.68) = .73, P = .49). Weak negative relationship (r = -12, P = .29) occurred between skin surface temperature and interface pressure, and sacral skin surface temperature was significantly lower for the left trochanter only (F = (8.68) = 7.05, P = .002). Although hypotheses were not supported, more research is needed to understand how time in position and multiple chronic illnesses interact to affect skin pressure tolerance.
Layden, Joseph D; Malkova, Dalia; Nimmo, Myra A
2004-09-01
The main aim of this study was to investigate if whole body fat oxidation, after acipimox administration, during submaximal exercise in the cold, is different from that at temperate environments. Seven healthy recreationally active male subjects cycled at 70% Vo(2peak) for 60 minutes; once at 0 degrees C and once at 20 degrees C. To exclude availability, and therefore oxidation of plasma-derived nonesterified fatty acids (NEFA), 90 minutes before each cycling bout, subjects ingested 250 mg of the antilipolytic drug, acipimox. Blood and expired gas measurements were obtained at rest, immediately before exercise, and at 15, 30, 45, and 60 minutes of exercise. In both trials, after the ingestion of acipimox, plasma NEFA concentrations fell dramatically and immediately before and during exercise were lower than 0.05 mmol. L(-1) in both trials. Pre-exercise and exercise values of glycerol, glucose, triacylglycerol (TG), and rectal temperature (T(re)) were not different between the 0 degrees C and 20 degrees C trials. During exercise at 0 degrees C, skin temperature (T(sk)) was significantly reduced from pre-exercise values (P <.05) and at all time points was significantly lower than during exercise at 20 degrees C. Muscle temperature did not differ between trials but in both trials was lower (P <.05) at 1 cm depth than at 3 cm and 2 cm. Gross energy expenditure of cycling (0 degrees C trial, 3.6 +/- 0.1 MJ; 20 degrees C trial, 3.6 +/- 0.1 MJ), the oxidation rates of carbohydrate (0 degrees C, 32.4 +/- 0.5 KJ. min(-1); 20 degrees C, 32.6 +/- 0.7 KJ. min(-1)) and fat (0 degrees C, 24.6 +/- 1.2 KJ. min(-1); 20 degrees C, 23.0 +/- 1.8 KJ. min(-1)), and the proportion of energy derived from fat (0 degrees C, 45 +/- 1 %; 20 degrees C, 40 +/- 4%) and carbohydrate (0 degrees C, 55 +/- 1%; 20 degrees C, 58 +/- 3%) were not different between the 2 trials. In conclusion, after acipimox administration, whole body fat oxidation during exercise, designed to avoid adjustment of core temperature or thermogenesis, is not different at 0 degrees C compared with 20 degrees C. This allows the inference that during submaximal exercise, cold has no effect on the utilization of intramuscular TG (IMTG).
Petrofsky, Jerrold; Paluso, Dominic; Anderson, Devyn; Swan, Kristin; Yim, Jong Eun; Murugesan, Vengatesh; Chindam, Tirupathi; Goraksh, Neha; Alshammari, Faris; Lee, Haneul; Trivedi, Moxi; Hudlikar, Akshay N; Katrak, Vahishta
2011-04-01
As predicted by the Pennes equation, skin blood flow is a major contributor to the removal of heat from an external heat source. This protects the skin from erythema and burns. But, for a person in a thermally neutral room, the skin is normally much cooler than arterial blood. Therefore, if skin blood flow (BF) increases, it should initially warm the skin paradoxically. To examine this phenomenon, 10 young male and female subjects participated in a series of experiments to examine the contribution of skin blood flow in the initial warming the skin after the application of local heat. Heat flow was measured by the use of a thermode above the brachioradialis muscle. The thermode was warmed by constant temperature water at 44°C entering the thermode at a water flow rate of 100 cm(3)/min. Skin temperature was measured by a thermistor and blood flow in the underlying skin was measured by a laser Doppler imager in single point mode. The results of the experiments showed that, when skin temperature is cool (31-32°C), the number of calories being transferred to the skin from the thermode cannot account for the rise in skin temperature alone. A significant portion of the rise in skin temperature is due to the warm arterialized blood traversing the skin from the core areas of the body. However, as skin temperature approaches central core temperature, it becomes less of a heat source and more of a heat sync such that when skin temperature is at or above core temperature, the blood flow to the skin, as predicted by Pennes, becomes a heat sync pulling heat from the thermode. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.
Control of skin blood flow, sweating, and heart rate - Role of skin vs. core temperature
NASA Technical Reports Server (NTRS)
Wyss, C. R.; Brengelmann, G. L.; Johnson, J. M.; Rowell, L. B.; Niederberger, M.
1974-01-01
A study was conducted to generate quantitative expressions for the influence of core temperature, skin temperature, and the rate of change of skin temperature on sweat rate, skin blood flow, and heart rate. A second goal of the study was to determine whether the use of esophageal temperature rather than the right atrial temperature as a measure of core temperature would lead to different conclusions about the control of measured effector variables.
Aerial thermography studies of power plant heated lakes
NASA Astrophysics Data System (ADS)
Villa-Aleman, Eliel; Garrett, Alfred J.; Kurzeja, Robert J.; Pendergast, Malcolm M.
2000-03-01
Remote sensing temperature measurements of water bodies is complicated by the temperature differences between the true surface or `skin' water and the bulk water below. Weather conditions control the reduction of the skin temperature relative to the bulk water temperature. Typical skin temperature depressions range from a few tenths of a degree Celsius to more than one degree. In this research project, the Savannah River Technology Center used aerial thermography and surface-based meteorological and water temperature measurements to study a power plant cooling lake in South Carolina. Skin and bulk water temperatures were measured simultaneously for imagery calibration and to product a database for modeling of skin temperature depressions as a function of weather and bulk water temperatures. This paper will present imagery that illustrates how the skin temperature depression was affected by different conditions in several locations on the lake and will present skin temperature modeling results.
Supraclavicular skin temperature and BAT activity in lean healthy adults.
van der Lans, Anouk A J J; Vosselman, Maarten J; Hanssen, Mark J W; Brans, Boudewijn; van Marken Lichtenbelt, Wouter D
2016-01-01
The 'gold standard' for measuring brown adipose tissue (BAT) in humans is [(18)F]FDG-PET/CT-imaging. With this technique subjects are exposed to ionizing radiation and are therefore limited in the number of scans that can be performed. We investigated the relation between supraclavicular skin temperatures and BAT activity values using a strictly temperature-controlled air-cooling protocol. Data of 36 male subjects was analyzed. BAT activity was evaluated by [(18)F]FDG-PET/CT-imaging and skin temperature was measured by means of wireless temperature sensors. Supraclavicular skin temperature dropped less compared to skin temperatures at other sites (all P values <0.01). A significant positive correlation was found between the change in supraclavicular skin temperature with BAT activity (R (2) 0.23), and the change in supraclavicular skin temperature and non-shivering thermogenesis (R (2) 0.18, both P values <0.01). The correlations indicate that supraclavicular skin temperature (changes) can potentially be used as a qualitative measure of BAT activity and BAT thermogenesis.
Estimation of Thermal Sensation Based on Wrist Skin Temperatures.
Sim, Soo Young; Koh, Myung Jun; Joo, Kwang Min; Noh, Seungwoo; Park, Sangyun; Kim, Youn Ho; Park, Kwang Suk
2016-03-23
Thermal comfort is an essential environmental factor related to quality of life and work effectiveness. We assessed the feasibility of wrist skin temperature monitoring for estimating subjective thermal sensation. We invented a wrist band that simultaneously monitors skin temperatures from the wrist (i.e., the radial artery and ulnar artery regions, and upper wrist) and the fingertip. Skin temperatures from eight healthy subjects were acquired while thermal sensation varied. To develop a thermal sensation estimation model, the mean skin temperature, temperature gradient, time differential of the temperatures, and average power of frequency band were calculated. A thermal sensation estimation model using temperatures of the fingertip and wrist showed the highest accuracy (mean root mean square error [RMSE]: 1.26 ± 0.31). An estimation model based on the three wrist skin temperatures showed a slightly better result to the model that used a single fingertip skin temperature (mean RMSE: 1.39 ± 0.18). When a personalized thermal sensation estimation model based on three wrist skin temperatures was used, the mean RMSE was 1.06 ± 0.29, and the correlation coefficient was 0.89. Thermal sensation estimation technology based on wrist skin temperatures, and combined with wearable devices may facilitate intelligent control of one's thermal environment.
Estimation of Thermal Sensation Based on Wrist Skin Temperatures
Sim, Soo Young; Koh, Myung Jun; Joo, Kwang Min; Noh, Seungwoo; Park, Sangyun; Kim, Youn Ho; Park, Kwang Suk
2016-01-01
Thermal comfort is an essential environmental factor related to quality of life and work effectiveness. We assessed the feasibility of wrist skin temperature monitoring for estimating subjective thermal sensation. We invented a wrist band that simultaneously monitors skin temperatures from the wrist (i.e., the radial artery and ulnar artery regions, and upper wrist) and the fingertip. Skin temperatures from eight healthy subjects were acquired while thermal sensation varied. To develop a thermal sensation estimation model, the mean skin temperature, temperature gradient, time differential of the temperatures, and average power of frequency band were calculated. A thermal sensation estimation model using temperatures of the fingertip and wrist showed the highest accuracy (mean root mean square error [RMSE]: 1.26 ± 0.31). An estimation model based on the three wrist skin temperatures showed a slightly better result to the model that used a single fingertip skin temperature (mean RMSE: 1.39 ± 0.18). When a personalized thermal sensation estimation model based on three wrist skin temperatures was used, the mean RMSE was 1.06 ± 0.29, and the correlation coefficient was 0.89. Thermal sensation estimation technology based on wrist skin temperatures, and combined with wearable devices may facilitate intelligent control of one’s thermal environment. PMID:27023538
Gil-Martínez, Alfonso; Navarro-Fernández, Gonzalo; Mangas-Guijarro, María Ángeles; Lara-Lara, Manuel; López-López, Almudena; Fernández-Carnero, Josué; La Touche, Roy
2017-11-01
To compare patients with chronic migraine (CM) and chronic temporomandibular disorders (TMD) on disability, pain, and fear avoidance factors and to associate these variables within groups. Descriptive, cross-sectional study. A neurology department and a temporomandibular disorders consult in a tertiary care center. A total of 50 patients with CM and 51 patients with chronic TMD, classified by international criteria classifications. The variables evaluated included pain intensity (visual analog scale [VAS]), neck disability (NDI), craniofacial pain and disability (CF-PDI), headache impact (HIT-6), pain catastrophizing (PCS), and kinesiophobia (TSK-11). Statistically significant differences were found between the CM group and the chronic TMD group in CF-PDI (P < 0.001), PCS (P = 0.03), and HIT-6 (P < 0.001); however, there were no differences between the CM group and the VAS, NDI, and TSK-11 groups (P > 0.05). For the chronic TMD group, the combination of NDI and TSK-11 was a significant covariate model of CF-PDI (adjusted R2 = 0.34). In the CM group, the regression model showed that NDI was a significant predictive factor for HIT-6 (adjusted R2 = 0.19). Differences between the CM group and the chronic TMD group were found in craniofacial pain and disability, pain catastrophizing, and headache impact, but they were similar for pain intensity, neck disability, and kinesiophobia. Neck disability and kinesiophobia were covariates of craniofacial pain and disability (34% of variance) for chronic TMD. In the CM group, neck disability was a predictive factor for headache impact (19.3% of variance). © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com
Accurate and precise characterization of exposure of aquatic ecological resources to chemical stressors is required for ecological risk assessment. Within this assessment, the study of the vulnerability of these resources requires comparative exposure assessments across watershe...
Relationships between skin temperature and temporal summation of heat and cold pain.
Mauderli, Andre P; Vierck, Charles J; Cannon, Richard L; Rodrigues, Anthony; Shen, Chiayi
2003-07-01
Temporal summation of heat pain during repetitive stimulation is dependent on C nociceptor activation of central N-methyl-d-aspartate (NMDA) receptor mechanisms. Moderate temporal summation is produced by sequential triangular ramps of stimulation that control skin temperature between heat pulses but do not elicit distinct first and second pain sensations. Dramatic summation of second pain is produced by repeated contact of the skin with a preheated thermode, but skin temperature between taps is not controlled by this procedure. Therefore relationships between recordings of skin temperature and psychophysical ratings of heat pain were evaluated during series of repeated skin contacts. Surface and subcutaneous recordings of skin temperatures revealed efficient thermoregulatory compensation for heat stimulation at interstimulus intervals (ISIs) ranging from 2 to 8 s. Temporal summation of heat pain was strongly influenced by the ISIs and cannot be explained by small increases in skin temperature between taps or by heat storage throughout a stimulus series. Repetitive brief contact with a precooled thermode was utilized to evaluate whether temporal summation of cold pain occurs, and if so, whether it is influenced by skin temperature. Surface and subcutaneous recordings of skin temperature revealed a sluggish thermoregulatory compensation for repetitive cold stimulation. In contrast to heat stimulation, skin temperature did not recover between cold stimuli throughout ISIs of 3-8 s. Psychophysically, repetitive cold stimulation produced an aching pain sensation that progressed gradually and radiated beyond the site of stimulation. The magnitude of aching pain was well related to skin temperature and thus appeared to be established primarily by peripheral factors.
van der Heide, Astrid; Werth, Esther; Donjacour, Claire E H M; Reijntjes, Robert H A M; Lammers, Gert Jan; Van Someren, Eus J W; Baumann, Christian R; Fronczek, Rolf
2016-11-01
Previous laboratory studies in narcolepsy patients showed altered core body and skin temperatures, which are hypothesised to be related to a disturbed sleep wake regulation. In this ambulatory study we assessed temperature profiles in normal daily life, and whether sleep attacks are heralded by changes in skin temperature. Furthermore, the effects of three months of treatment with sodium oxybate (SXB) were investigated. Twenty-five narcolepsy patients and 15 healthy controls were included. Core body, proximal and distal skin temperatures, and sleep-wake state were measured simultaneously for 24 hours in ambulatory patients. This procedure was repeated in 16 narcolepsy patients after at least 3 months of stable treatment with SXB. Increases in distal skin temperature and distal-to-proximal temperature gradient (DPG) strongly predicted daytime sleep attacks (P < 0.001). As compared to controls, patients had a higher proximal and distal skin temperature in the morning, and a lower distal skin temperature during the night (all P < 0.05). Furthermore, they had a higher core body temperature during the first part of the night (P < 0.05), which SXB decreased (F = 4.99, df = 1, P = 0.03) to a level similar to controls. SXB did not affect skin temperature. This ambulatory study demonstrates that daytime sleep attacks were preceded by clear changes in distal skin temperature and DPG. Furthermore, changes in core body and skin temperature in narcolepsy, previously only studied in laboratory settings, were partially confirmed. Treatment with SXB resulted in a normalisation of the core body temperature profile. Future studies should explore whether predictive temperature changes can be used to signal or even prevent sleep attacks. © 2016 Associated Professional Sleep Societies, LLC.
Hadid, A; Yanovich, R; Erlich, T; Khomenok, G; Moran, D S
2008-09-01
The present study was conducted in order to evaluate whether physiological strain is alleviated by a new personal cooling system (CS) consisting of a layered vest and integrated blower that generate a flow of air. Twelve male volunteers were exposed to climatic conditions of 40 degrees C, 40%RH (40/40), and 35 degrees C, 60%RH (35/60) during a 115 min exercise routine, followed by 70 min resting recovery, while wearing a battle dress uniform (BDU) and a ballistic vest, with (COOL) or without (NOCOOL) CS. The CS was able to attenuate the physiological strain levels during exercise, when compared to identical exposures without the CS. Temperature elevation, (DeltaT (re)) after 100 min of exercise, was lower by 0.26 +/- 0.20 and 0.34 +/- 0.21 degrees C in 40/40 and 35/60, respectively, (p < 0.05). Mean skin temperature (T(sk)) was lower by 0.9 +/- 0.4 and 0.6 +/- 0.5 degrees C for 40/40 and 35/60, respectively. Heart rate (HR) was not significantly different for COOL versus NOCOOL for 40/40. At 35/60, HR was lower by 10 beats per min (bpm) (p < 0.05). Physiological strain index (PSI) was 9 and 21% lower for the 40/40 and 35/60, respectively, for COOL versus NOCOOL (p < 0.05). Heat storage (S) rates were 19 and 24% lower and sweat rates were 21 and 25% lower for the 40/40 and 35/60, respectively, for COOL versus NOCOOL (p < 0.05). However, the CS was not effective in alleviating physiological strain during resting recovery with no difference in T (re) cooling rate, S, or HR drop rate between groups over resting recovery periods. The CS tested in this study was found to be an effective tool for lowering physiological strain while exercising but not during resting recovery. Therefore, the CS should be further developed in order to achieve greater attenuation of the thermal strain during exercise and improve effectiveness during rest. Overall, it has the potential to be useful for both military and sports personnel.
Breathable and Stretchable Temperature Sensors Inspired by Skin.
Chen, Ying; Lu, Bingwei; Chen, Yihao; Feng, Xue
2015-06-22
Flexible electronics attached to skin for healthcare, such as epidermal electronics, has to struggle with biocompatibility and adapt to specified environment of skin with respect to breath and perspiration. Here, we report a strategy for biocompatible flexible temperature sensors, inspired by skin, possessing the excellent permeability of air and high quality of water-proof by using semipermeable film with porous structures as substrate. We attach such temperature sensors to underarm and forearm to measure the axillary temperature and body surface temperature respectively. The volunteer wears such sensors for 24 hours with two times of shower and the in vitro test shows no sign of maceration or stimulation to the skin. Especially, precise temperature changes on skin surface caused by flowing air and water dropping are also measured to validate the accuracy and dynamical response. The results show that the biocompatible temperature sensor is soft and breathable on the human skin and has the excellent accuracy compared to mercury thermometer. This demonstrates the possibility and feasibility of fully using the sensors in long term body temperature sensing for medical use as well as sensing function of artificial skin for robots or prosthesis.
A New Approach to Defining Human Touch Temperature Standards
NASA Technical Reports Server (NTRS)
Ungar, Eugene; Stroud, Kenneth
2010-01-01
Defining touch temperature limits for skin contact with both hot and cold objects is important to prevent pain and skin damage, which may affect task performance or become a safety concern. Pain and skin damage depend on the skin temperature during contact, which depends on the contact thermal conductance, the object's initial temperature, and its material properties. However, previous spacecraft standards have incorrectly defined touch temperature limits in terms of a single object temperature value for all materials, or have provided limited material-specific values which do not cover the gamut of likely designs. A new approach has been developed for updated NASA standards, which defines touch temperature limits in terms of skin temperature at pain onset for bare skin contact with hot and cold objects. The authors have developed an analytical verification method for safe hot and cold object temperatures for contact times from 1 second to infinity.
A New Approach to Defining Human Touch Temperature Standards
NASA Technical Reports Server (NTRS)
Ungar, Eugene; Stroud, Kenneth
2009-01-01
Defining touch temperature limits for skin contact with both hot and cold objects is important to prevent pain and skin damage, which may affect task performance or become a safety concern. Pain and skin damage depend on the resulting skin temperature during contact, which depends on the object s initial temperature, its material properties and its ability to transfer heat. However, previous spacecraft standards have incorrectly defined touch temperature limits in terms of a single object temperature value for all materials, or have provided limited material-specific values which do not cover the gamut of most designs. A new approach is being used in new NASA standards, which defines touch temperature limits in terms of skin temperature at pain onset for bare skin contact with hot and cold objects. The authors have developed an analytical verification method for safe hot and cold object temperatures for contact times from 1 second to infinity.
Tansey, E A; Roe, S M; Johnson, C J
2014-03-01
When a subject is heated, the stimulation of temperature-sensitive nerve endings in the skin, and the raising of the central body temperature, results in the reflex release of sympathetic vasoconstrictor tone in the skin of the extremities, causing a measurable temperature increase at the site of release. In the sympathetic release test, the subject is gently heated by placing the feet and calves in a commercially available foot warming pouch or immersing the feet and calves in warm water and wrapping the subject in blankets. Skin blood flow is estimated from measurements of skin temperature in the fingers. Normally skin temperature of the fingers is 65-75°F in cool conditions (environmental temperature: 59-68°F) and rises to 85-95°F during body heating. Deviations in this pattern may mean that there is abnormal sympathetic vasoconstrictor control of skin blood flow. Abnormal skin blood flow can substantially impair an individual's ability to thermoregulate and has important clinical implications. During whole body heating, the skin temperature from three different skin sites is monitored and oral temperature is monitored as an index of core temperature. Students determine the fingertip temperature at which the reflex release of sympathetic activity occurs and its maximal attainment, which reflects the vasodilating capacity of this cutaneous vascular bed. Students should interpret typical sample data for certain clinical conditions (Raynaud's disease, peripheral vascular disease, and postsympathectomy) and explain why there may be altered skin blood flow in these disorders.
Hand and finger dexterity as a function of skin temperature, EMG, and ambient condition.
Chen, Wen-Lin; Shih, Yuh-Chuan; Chi, Chia-Fen
2010-06-01
This article examines the changes in skin temperature (finger, hand, forearm), manual performance (hand dexterity and strength), and forearm surface electromyograph (EMG) through 40-min, 11 degrees C water cooling followed by 15-min, 34 degrees C water rewarming; additionally, it explores the relationship between dexterity and the factors of skin temperature, EMG, and ambient condition. Hand exposure in cold conditions is unavoidable and significantly affects manual performance. Two tasks requiring gross and fine dexterity were designed, namely, nut loosening and pin insertion, respectively. The nested-factorial design includes factors of gender, participant (nested within gender), immersion duration, muscle type (for EMG), and location (for skin temperature). The responses are changes in dexterity, skin temperature, normalized amplitude of EMG, and grip strength. Finally, factor analysis and stepwise regression are used to explore factors affecting hand and finger dexterity. Dexterity, EMG, and skin temperature fell with prolonged cooling, but the EMG of the flexor digitorum superficialis remained almost unchanged during the nut loosening task. All responses but the forearm skin temperature recovered to the baseline level at the end of rewarming. The three factors extracted by factor analysis are termed skin temperature, ambient condition, and EMG. They explain approximately two thirds of the variation of the linear models for both dexterities, and the factor of skin temperature is the most influential. Sustained cooling and warming significantly decreases and increases finger, hand, and forearm skin temperature. Dexterity, strength, and EMG are positively correlated to skin temperature. Therefore, keeping the finger, hand, and forearm warm is important to maintaining hand performance. The findings could be helpful to building safety guidelines for working in cold environments.
Effect of hypoxic breathing on cutaneous temperature recovery in man
NASA Astrophysics Data System (ADS)
Fahim, Mohammad
1992-03-01
Effect of hypoxia (12% O2) on skin temperature recovery was studied on healthy young men. Forty male volunteers free of any respiratory disorder were randomly selected to participate in the study. Skin temperature, peripheral blood flow, heart rate and end expiratory PO2 and PCO2 were measured. During hyoxic ventilation the peripheral blood flow was reduced and a corresponding drop in skin temperature occurred. This was partly due to hyperventilation associated with hypoxic ventilation. The recovery of skin temperature after cooling the hand for 2 min in cold water (10 12° C) took 5.5±0.1 min during normal air breathing; during hypoxic ventilation even after 9.1±0.3 min when the skin temperature recovery curve plateaued, the skin temperature remained about 2° C below control. The results of the present investigation indicate that hypoxia interferes with the normal functioning of the thermoregulatory mechanism in man. Hyperventilation associated with hypoxic ventilation is also partly responsible for incomplete recovery of skin temperature.
Use of skin temperature to predict tolerance to thermal environments.
DOT National Transportation Integrated Search
1971-01-01
Skin temperature is a sensitive index of the effect of the thermal environment on the seminude man. Skin temperatures and tolerance times from several studies have been utilized in an attempt to establish a relationship between (1) final skin tempera...
Wingo, Jonathan E; Low, David A; Keller, David M; Brothers, R Matthew; Shibasaki, Manabu; Crandall, Craig G
2010-11-01
Sweat rate (SR) is reduced in locally cooled skin, which may result from decreased temperature and/or parallel reductions in skin blood flow. The purpose of this study was to test the hypotheses that decreased skin blood flow and decreased local temperature each independently attenuate sweating. In protocols I and II, eight subjects rested supine while wearing a water-perfused suit for the control of whole body skin and internal temperatures. While 34°C water perfused the suit, four microdialysis membranes were placed in posterior forearm skin not covered by the suit to manipulate skin blood flow using vasoactive agents. Each site was instrumented for control of local temperature and measurement of local SR (capacitance hygrometry) and skin blood flow (laser-Doppler flowmetry). In protocol I, two sites received norepinephrine to reduce skin blood flow, while two sites received Ringer solution (control). All sites were maintained at 34°C. In protocol II, all sites received 28 mM sodium nitroprusside to equalize skin blood flow between sites before local cooling to 20°C (2 sites) or maintenance at 34°C (2 sites). In both protocols, individuals were then passively heated to increase core temperature ~1°C. Both decreased skin blood flow and decreased local temperature attenuated the slope of the SR to mean body temperature relationship (2.0 ± 1.2 vs. 1.0 ± 0.7 mg·cm(-2)·min(-1)·°C(-1) for the effect of decreased skin blood flow, P = 0.01; 1.2 ± 0.9 vs. 0.07 ± 0.05 mg·cm(-2)·min(-1)·°C(-1) for the effect of decreased local temperature, P = 0.02). Furthermore, local cooling delayed the onset of sweating (mean body temperature of 37.5 ± 0.4 vs. 37.6 ± 0.4°C, P = 0.03). These data demonstrate that local cooling attenuates sweating by independent effects of decreased skin blood flow and decreased local skin temperature.
Insulation disks on the skin to estimate muscle temperature.
Brajkovic, Dragan; Ducharme, Michel B; Webb, Paul; Reardon, Frank D; Kenny, Glen P
2006-08-01
This study examined the use of insulation disks placed on the skin to estimate muscle temperature in resting subjects exposed to a thermoneutral (28 degrees C) ambient environment. The working hypothesis was that the skin temperature under each insulation disk would increase to a value corresponding to a specific muscle temperature measured by a control probe at 0.8+/-0.2, 1.3+/-0.2, 1.8+/-0.2, 2.3+/-0.2, and 2.8+/-0.2 cm below the skin surface. Eight subjects sat for 120 min while lateral thigh skin temperatures and vastus lateralis muscle temperature were directly measured. Vastus lateralis temperature was estimated non-invasively using two 5 cm diameter foam neoprene disks which were placed on top of the skin temperature probes (from time 60 to 120 min) located at 15.3 and 26.3 cm superior to the patella. The disks at the two locations were 3.2 and 4.8 mm thick, respectively. The placement of the 3.2- and 4.8-mm disks on the thigh for a minimum of 15 and 20 min, respectively, resulted in an increase in skin temperature under the disks which corresponded to the lateral thigh muscle temperature measured directly and invasively at 0.8+/-0.2 and 1.3+/-0.2 cm, respectively, below the skin.
Station Magnitude Bias - Its Determination, Causes, and Effects
1977-04-29
TSK Tsukuba, Honshu, Japan TUC (W) Tucson, Arizona TUL (W) Tulsa, Oklahoma TVO Taravao, French Polynesia UBO* Uinta Basin , Utah VAH Vaihoa...8217 structures such as the western US, and lowest in stable regions such as shields and deep ocean basins . High attenuation further appears to be well
van der Heide, Astrid; Werth, Esther; Donjacour, Claire E.H.M.; Reijntjes, Robert H.A.M.; Lammers, Gert Jan; Van Someren, Eus J.W.; Baumann, Christian R.; Fronczek, Rolf
2016-01-01
Study Objectives: Previous laboratory studies in narcolepsy patients showed altered core body and skin temperatures, which are hypothesised to be related to a disturbed sleep wake regulation. In this ambulatory study we assessed temperature profiles in normal daily life, and whether sleep attacks are heralded by changes in skin temperature. Furthermore, the effects of three months of treatment with sodium oxybate (SXB) were investigated. Methods: Twenty-five narcolepsy patients and 15 healthy controls were included. Core body, proximal and distal skin temperatures, and sleep-wake state were measured simultaneously for 24 hours in ambulatory patients. This procedure was repeated in 16 narcolepsy patients after at least 3 months of stable treatment with SXB. Results: Increases in distal skin temperature and distal-to-proximal temperature gradient (DPG) strongly predicted daytime sleep attacks (P < 0.001). As compared to controls, patients had a higher proximal and distal skin temperature in the morning, and a lower distal skin temperature during the night (all P < 0.05). Furthermore, they had a higher core body temperature during the first part of the night (P < 0.05), which SXB decreased (F = 4.99, df = 1, P = 0.03) to a level similar to controls. SXB did not affect skin temperature. Conclusions: This ambulatory study demonstrates that daytime sleep attacks were preceded by clear changes in distal skin temperature and DPG. Furthermore, changes in core body and skin temperature in narcolepsy, previously only studied in laboratory settings, were partially confirmed. Treatment with SXB resulted in a normalisation of the core body temperature profile. Future studies should explore whether predictive temperature changes can be used to signal or even prevent sleep attacks. Citation: van der Heide A, Werth E, Donjacour CE, Reijntjes RH, Lammers GJ, Van Someren EJ, Baumann CR, Fronczek R. Core body and skin temperature in type 1 narcolepsy in daily life; effects of sodium oxybate and prediction of sleep attacks. SLEEP 2016;39(11):1941–1949. PMID:27568803
Hyperbaric gaseous cryotherapy: effects on skin temperature and systemic vasoconstriction.
Mourot, Laurent; Cluzeau, Christian; Regnard, Jacques
2007-10-01
To compare skin-surface cooling caused by the application of an ice bag (15min) and the projection of carbon dioxide microcristals (2min) under high pressure (75 bar) and low temperature (-78 degrees C), a modality called hyperbaric gaseous cryotherapy. Randomized controlled trial with repeated measure. Laboratory experiment. Twelve healthy male subjects (mean +/- standard deviation, 22.9+/-1.8y). Ice bag and hyperbaric gaseous cryotherapy were randomly applied on the skin of the nondominant hand. Skin temperature of the cooled (dorsal and palmar sides) and contralateral (dorsal side) hands were continuously measured with thermistor surface-contact probes before, during, and after (30min) cooling. Hyperbaric gaseous cryotherapy projection induced a large decrease (P<.05) of the dorsal skin temperature of the cooled hand (from 32.5 degrees +/-0.5 degrees C to 7.3 degrees +/-0.8 degrees C) and a significant decrease of the skin temperature of the palmar side and of the contralateral hand. The skin temperature of the dorsal side of the cooled hand was decreased with an ice bag (from 32.5 degrees +/-0.6 degrees C to 13.9 degrees +/-0.7 degrees C, P<.05). However, the lowest temperature was significantly higher than during hyperbaric gaseous cryotherapy, and no significant changes in the other skin temperatures were observed. Rewarming was equal after the 2 modalities, highlighting a more rapid increase of the skin temperature after hyperbaric gaseous cryotherapy. Hyperbaric gaseous cryotherapy projection decreased the skin temperature of the cooled and contralateral hand, suggesting a systemic skin vasoconstriction response. On the other hand, the vascular responses triggered by ice pack cooling appeared limited and localized to the cooled area.
Separation of carbohydrates using hydrophilic interaction liquid chromatography.
Fu, Qing; Liang, Tu; Li, Zhenyu; Xu, Xiaoyong; Ke, Yanxiong; Jin, Yu; Liang, Xinmiao
2013-09-20
A strategy was developed to rapidly evaluate chromatographic properties of hydrophilic interaction chromatography (HILIC) columns for separating carbohydrates. Seven HILIC columns (Silica, Diol, TSK Amide-80, XAmide, Click Maltose, Click β-CD, and Click TE-Cys columns) were evaluated by using three monosaccharide and seven disaccharides as probes. The influence of column temperature on the peak shape and tautomerization of carbohydrates, as well as column selectivity were investigated. The influence of surface charge property on the retention was also studied by using glucose, glucuronic acid, and glucosamine, which indicated that buffer salt concentration and pH value in mobile phase was necessary to control the ionic interactions between ionic carbohydrates and HILIC columns. According to evaluation results, the XAmide column was selected as an example to establish experimental schemes for separation of complex mixtures of oligosaccharide. Copyright © 2013 Elsevier Ltd. All rights reserved.
Effect of temperature on the passivation behavior of steel rebar
NASA Astrophysics Data System (ADS)
Chen, Shan-meng; Cao, Bei; Wu, Yin-shun; Ma, Ke
2014-05-01
Steel rebar normally forms an oxide or rusty skin before it is embedded into concrete and the passivation properties of this skin will be heavily influenced by temperature. To study the effect of temperature on the passivation properties of steel rebar under different surface conditions, we conducted scanning electron microscopy (SEM) observations and electrochemical measurements, such as measurements of the free corrosion potential and polarization curves of HPB235 steel rebar. These measurements identified three kinds of surfaces: polished, oxide skin, and rusty skin. Our results show that the passivation properties of all the surface types decrease with the increase of temperature. Temperature has the greatest effect on the rusty-skin rebar and least effect on the polished steel rebar, because of cracks and crevices on the mill scale on the steel rebar's surface. The rusty-skin rebar exhibits the highest corrosion rate because crevice corrosion can accelerate the corrosion of the steel rebar, particularly at high temperature. The results also indicate that the threshold temperatures of passivation for the oxide-skin rebar and the rusty-skin rebar are 37°C and 20°C, respectively.
Breathable and Stretchable Temperature Sensors Inspired by Skin
NASA Astrophysics Data System (ADS)
Chen, Ying; Lu, Bingwei; Chen, Yihao; Feng, Xue
2015-06-01
Flexible electronics attached to skin for healthcare, such as epidermal electronics, has to struggle with biocompatibility and adapt to specified environment of skin with respect to breath and perspiration. Here, we report a strategy for biocompatible flexible temperature sensors, inspired by skin, possessing the excellent permeability of air and high quality of water-proof by using semipermeable film with porous structures as substrate. We attach such temperature sensors to underarm and forearm to measure the axillary temperature and body surface temperature respectively. The volunteer wears such sensors for 24 hours with two times of shower and the in vitro test shows no sign of maceration or stimulation to the skin. Especially, precise temperature changes on skin surface caused by flowing air and water dropping are also measured to validate the accuracy and dynamical response. The results show that the biocompatible temperature sensor is soft and breathable on the human skin and has the excellent accuracy compared to mercury thermometer. This demonstrates the possibility and feasibility of fully using the sensors in long term body temperature sensing for medical use as well as sensing function of artificial skin for robots or prosthesis.
Breathable and Stretchable Temperature Sensors Inspired by Skin
Chen, Ying; Lu, Bingwei; Chen, Yihao; Feng, Xue
2015-01-01
Flexible electronics attached to skin for healthcare, such as epidermal electronics, has to struggle with biocompatibility and adapt to specified environment of skin with respect to breath and perspiration. Here, we report a strategy for biocompatible flexible temperature sensors, inspired by skin, possessing the excellent permeability of air and high quality of water-proof by using semipermeable film with porous structures as substrate. We attach such temperature sensors to underarm and forearm to measure the axillary temperature and body surface temperature respectively. The volunteer wears such sensors for 24 hours with two times of shower and the in vitro test shows no sign of maceration or stimulation to the skin. Especially, precise temperature changes on skin surface caused by flowing air and water dropping are also measured to validate the accuracy and dynamical response. The results show that the biocompatible temperature sensor is soft and breathable on the human skin and has the excellent accuracy compared to mercury thermometer. This demonstrates the possibility and feasibility of fully using the sensors in long term body temperature sensing for medical use as well as sensing function of artificial skin for robots or prosthesis. PMID:26095941
de Velasco, Jesus Barraza; Tattersall, Glenn J
2008-09-01
One physiological mechanism used by reptiles to remain within thermal optima is their ability to reversibly alter skin colour, imparting changes in overall reflectance, and influencing the rate of heat gain from incident radiation. The ability to lighten or darken their skin is caused by the movement of pigment within the dermal chromatophore cells. Additionally, lizards, as ectotherms, significantly lower their preferred body temperatures when experiencing stressors such as hypoxia. This decrease in preferred temperature has been proposed to be the result of a downward adjustment of the thermal set-point, the temperature around which the body temperature is typically defended. We tested the hypothesis that lightening of the skin in lizards would be modified by hypoxia in a manner consistent with the known reduction in preferred temperatures. Skin colouration values of the dorsal skin of bearded dragons were analysed at three different levels of oxygen (20.8, 9.9 and 4.9 kPa) and at temperatures spanning the preferred temperature range (30, 32, 34, 36, 38 and 40 C). Hypoxic lizards lightened their skin at lower ambient temperatures more than normoxic ones, and in an oxygen-dependent fashion. The orchestrated adjustment of skin reflectance suggests that this physiological trait is being regulated at a new and lower set-point. Evidence from this study demonstrates that skin colouration plays a role in body temperature regulation and that the reduction in temperature set-point so prevalent in hypoxia is also manifested in this physiological trait.
WE-FG-202-01: Early Prediction of Radiotherapy Induced Skin Reactions Using Dynamic Infrared Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biswal, N; Cifter, G; Sun, J
Purpose: To predict radiotherapy induced skin reactions using dynamic infrared imaging. Methods: Thermal images were captured by our homebuilt system consisting of two flash lamps and an infrared (IR) camera. The surface temperature of the skin was first raised by ∼ 6 oC from ∼1 ms flashes. The camera then captured a series of IR images for 10 seconds. For each image, a baseline skin temperature was recorded for 0.5sec before heat impulse. The temporal temperature gradients were calculated between a reference point (immediately after the flash) and at a time point 9sec after that. Thermal effusivity, an intrinsic thermalmore » property of a material, was calculated from the surface temperature decay of skin. We present experimental data in five patients undergoing radiation therapy, of which 2 were Head & Neck, 1 was Sarcoma and 2 were Breast cancer patients. The prescribed doses were 45 – 60 Gy in 25 – 30 fractions. Each patient was imaged before treatment and after every fifth fraction until end of the treatment course. An area on the skin, outside the radiation field, was imaged as control region. During imaging, each patient’s irradiated skins were scored based on RTOG skin morbidity scoring criteria. Results: Temperature gradient, which is the temperature recovery rate, depends on the thermal properties of underlying tissue. It was observed that, the skin temperature and temporal temperature gradient increases with delivered radiation dose and skin RTOG score. The treatment does not change effusivity of superficial skin layer, however there was a significant difference in effusivity between treated and control areas at depth of ∼ 1.5 – 1.8 mm, increases with dose. Conclusion: The higher temporal temperature gradient and effusivity from irradiated areas suggest that there is more fluid under the irradiated skin, which causes faster temperature recovery. The mentioned effects may be predictors of Moist Desquamation.« less
Schey, Bernadette M; Williams, David Y; Bucknall, Tracey
2010-01-01
To examine the evidential basis underpinning the monitoring of skin temperature and core-peripheral temperature gradient as elements of hemodynamic assessment in critically ill and adult cardiac surgical patients. Twenty-six studies examining the efficacy of skin temperature or temperature gradient as markers of hemodynamic status were selected as part of an integrative review. Evidence pertaining to the efficacy of these parameters as markers of cardiac function is equivocal and has not been well appraised in the adult cardiac surgical population. Skin temperature and systemic vascular resistance are also affected by factors other than cardiac output. Skin temperature and core-peripheral temperature gradient should not be considered in isolation from other hemodynamic parameters when assessing cardiac status until they are validated by further large-scale prospective studies. 2010. Published by Mosby, Inc.
Evaluation of Skin Temperatures Retrieved from GOES-8
NASA Technical Reports Server (NTRS)
Suggs, Ronnie, J.; Jedlovec, G. J.; Lapenta, W. M.; Haines, S. L.
2000-01-01
Skin temperatures derived from geostationary satellites have the potential of providing the temporal and spatial resolution needed for model assimilation. To adequately assess the potential improvements in numerical model forecasts that can be made by assimilating satellite data, an estimate of the accuracy of the skin temperature product is necessary. A particular skin temperature algorithm, the Physical Split Window Technique, that uses the longwave infrared channels of the GOES Imager has shown promise in recent model assimilation studies to provide land surface temperatures with reasonable accuracy. A comparison of retrieved GOES-8 skin temperatures from this algorithm with in situ measurements is presented. Various retrieval algorithm issues are addressed including surface emissivity
Komen, M M C; Smorenburg, C H; Nortier, J W R; van der Ploeg, T; van den Hurk, C J G; van der Hoeven, J J M
2016-12-01
The success of scalp cooling in preventing or reducing chemotherapy induced alopecia (CIA) is highly variable between patients undergoing similar chemotherapy regimens. A decrease of the scalp skin temperature seems to be an important factor, but data on the optimum temperature reached by scalp cooling to prevent CIA are lacking. This study investigated the relation between scalp skin temperature and its efficacy to prevent CIA. In this explorative study, scalp skin temperature was measured during scalp cooling in 62 breast cancer patients undergoing up to six cycles of anthracycline containing chemotherapy. Scalp skin temperature was measured by using two thermocouples at both temporal sides of the head. The primary end-point was the need for a wig or other head covering. Maximal cooling was reached after 45 min and was continued for 90 min after chemotherapy infusion. The scalp skin temperature after 45 min cooling varied from 10 °C to 31 °C, resulting in a mean scalp skin temperature of 19 °C (SEM: 0,4). Intrapersonal scalp skin temperatures during cooling were consistent for each chemotherapy cycle (ANOVA: P = 0,855). Thirteen out of 62 patients (21%) did not require a wig or other head covering. They appeared to have a significantly lower mean scalp skin temperature (18 °C; SEM: 0,7) compared to patients with alopecia (20 °C; SEM: 0,5) (P = 0,01). The efficacy of scalp cooling during chemotherapy is temperature dependent. A precise cut-off point could not be detected, but the best results seem to be obtained when the scalp temperature decreases below 18 °C. TRIALREGISTER. 3082. Copyright © 2016 Elsevier Ltd. All rights reserved.
Spatial temperature distribution in human hairy and glabrous skin after infrared CO2 laser radiation
2010-01-01
Background CO2 lasers have been used for several decades as an experimental non-touching pain stimulator. The laser energy is absorbed by the water content in the most superficial layers of the skin. The deeper located nociceptors are activated by passive conduction of heat from superficial to deeper skin layers. Methods In the current study, a 2D axial finite element model was developed and validated to describe the spatial temperature distribution in the skin after infrared CO2 laser stimulation. The geometry of the model was based on high resolution ultrasound scans. The simulations were compared to the subjective pain intensity ratings from 16 subjects and to the surface skin temperature distributions measured by an infrared camera. Results The stimulations were sensed significantly slower and less intense in glabrous skin than they were in hairy skin (MANOVA, p < 0.001). The model simulations of superficial temperature correlated with the measured skin surface temperature (r > 0.90, p < 0.001). Of the 16 subjects tested; eight subjects reported pricking pain in the hairy skin following a stimulus of 0.6 J/cm2 (5 W, 0.12 s, d1/e2 = 11.4 mm) only two reported pain to glabrous skin stimulation using the same stimulus intensity. The temperature at the epidermal-dermal junction (depth 50 μm in hairy and depth 133 μm in glabrous skin) was estimated to 46°C for hairy skin stimulation and 39°C for glabrous skin stimulation. Conclusions As compared to previous one dimensional heat distribution models, the current two dimensional model provides new possibilities for detailed studies regarding CO2 laser stimulation intensity, temperature levels and nociceptor activation. PMID:21059226
Wistrand, Camilla; Söderquist, Bo; Magnusson, Anders; Nilsson, Ulrica
2015-01-01
In clinical practice, patients who are awake often comment that cold surgical skin disinfectant is unpleasant. This is not only a problem of patients' experience; heat loss during the disinfection process is a problem that can result in hypothermia. Evidence for the efficacy of preheated disinfection is scarce. We tested whether preheated skin disinfectant was non-inferior to room-temperature skin disinfectant on reducing bacterial colonization during pacemaker implantation. This randomized, controlled, non-inferiority trial included 220 patients allocated to skin disinfection with preheated (36 °C) or room-temperature (20 °C) chlorhexidine solution in 70 % ethanol. Cultures were obtained by swabbing at 4 time-points; 1) before skin disinfection (skin surface), 2) after skin disinfection (skin surface), 3) after the incision (subcutaneously in the wound), and 4) before suturing (subcutaneously in the wound). The absolute difference in growth between patients treated with preheated versus room-temperature skin disinfectant was zero (90 % CI -0.101 to 0.101; preheated: 30 of 105 [28.6 %] vs. room-temperature: 32 of 112 [28.6 %]). The pre-specified margin for statistical non-inferiority in the protocol was set at 10 % for the preheated disinfectant. There were no significant differences between groups regarding SSIs three month postoperatively, which occurred in 0.9 % (1 of 108) treated with preheated and 1.8 % (2 of 112) treated with room-temperature skin disinfectant. Preheated skin disinfection is non-inferior to room-temperature disinfection in bacterial reduction. We therefore suggest that preheated skin disinfection become routine in clean surgery. The study is registered at ClinicalTrials.gov (NCTO2260479).
Is Kinesio Taping to Generate Skin Convolutions Effective for Increasing Local Blood Circulation?
Yang, Jae-Man; Lee, Jung-Hoon
2018-01-01
Background It is unclear whether traditional application of Kinesio taping, which produces wrinkles in the skin, is effective for improving blood circulation. This study investigated local skin temperature changes after the application of an elastic therapeutic tape using convolution and non-convolution taping methods (CTM/NCTM). Material/Methods Twenty-eight pain-free men underwent CTM and NCTM randomly applied to the right and left sides of the lower back. Using infrared thermography, skin temperature was measured before, immediately after application, 5 min later, 15 min later, and after the removal of the tape. Results Both CTM and NCTM showed a slight, but significant, decrease in skin temperature for up to 5 min. The skin temperature at 15 min and after the removal of the tape was not significantly different from the initial temperature for CTM and NCTM. There were also no significant differences in the skin temperatures between CTM and NCTM. Conclusions Our findings do not support a therapeutic effect of wrinkling the skin with elastic tape application as a technique to increase local blood flow. PMID:29332101
Is Kinesio Taping to Generate Skin Convolutions Effective for Increasing Local Blood Circulation?
Yang, Jae-Man; Lee, Jung-Hoon
2018-01-14
BACKGROUND It is unclear whether traditional application of Kinesio taping, which produces wrinkles in the skin, is effective for improving blood circulation. This study investigated local skin temperature changes after the application of an elastic therapeutic tape using convolution and non-convolution taping methods (CTM/NCTM). MATERIAL AND METHODS Twenty-eight pain-free men underwent CTM and NCTM randomly applied to the right and left sides of the lower back. Using infrared thermography, skin temperature was measured before, immediately after application, 5 min later, 15 min later, and after the removal of the tape. RESULTS Both CTM and NCTM showed a slight, but significant, decrease in skin temperature for up to 5 min. The skin temperature at 15 min and after the removal of the tape was not significantly different from the initial temperature for CTM and NCTM. There were also no significant differences in the skin temperatures between CTM and NCTM. CONCLUSIONS Our findings do not support a therapeutic effect of wrinkling the skin with elastic tape application as a technique to increase local blood flow.
Characterisation of regional skin temperatures in recreational surfers wearing a 2-mm wetsuit.
Corona, Luis J; Simmons, Grant H; Nessler, Jeff A; Newcomer, Sean C
2018-05-01
The purpose of this study was to investigate skin temperatures across surfers' bodies while wearing a wetsuit during recreational surfing. Forty-six male recreational surfers participated in this study. Participants were instrumented with eight wireless iButton thermal sensors for the measurement of skin temperature, a Polar RCX5 heart rate monitor and a 2-mm full wetsuit. Following instrumentation, participants were instructed to engage in recreational surfing activities as normal. Significant differences (p < 0.001) in skin temperature (T sk ) were found across the body while wearing a wetsuit during recreational surfing. In addition, regional skin temperature changed across the session for several regions of the body (p < 0.001), and the magnitude of these changes varied significantly between regions. We show for the first time that significant differences exist in skin temperature across the body while wearing a wetsuit during a typical recreational surfing session. These findings may have implications for future wetsuit design. Practitioner Summary: This study investigated the impact of wearing a wetsuit during recreational surfing on regional skin temperatures. Results from this study suggest that skin temperatures differ significantly across the body while wearing a 2-mm wetsuit during recreational surfing. These findings may have implications for future wetsuit design.
Firdaus, M Lutfi; Norisuye, Kazuhiro; Sato, Taishi; Urushihara, Shouhei; Nakagawa, Yusuke; Umetani, Shigeo; Sohrin, Yoshiki
2007-02-05
Here, we present the first simultaneous preconcentration and determination of ultratrace (pmol kg(-1) level) Zr, Hf, Nb, Ta and W in seawater, both in the form of dissolved and acid-dissolvable species. 8-Hydroxyquinoline (8HQ) bonded covalently to a vinyl polymer resin, TSK-8HQ, was used in a chelating adsorbent column to concentrate the metals. The greatest advantage of this resin is its endurance to 5M HF, since this is an effective eluent for all five metals. The analytes were successfully concentrated from 250 mL seawater with a 50-fold concentration factor through the column extraction and evaporation. The detection limit was 0.009-0.15 pmol kg(-1). The procedure blank determined using ultra pure water as a sample was 0.005-0.37 pmol kg(-1). The five metals were quantitatively recovered from seawater with good precision (2-4%). The effect of sample pH, sample flow rate, eluent composition and sample pretreatment were carefully studied. This method was applied to seawater.
Work ability is influenced by kinesiophobia among patients with persistent pain.
Åkerström, Mona-Lisa; Grimby-Ekman, Anna; Lundberg, Mari
2017-08-01
The purpose of this study was to investigate how kinesiophobia fluctuates in patients over a four weeks multimodal rehabilitation program and to study the relationship between work ability and kinesiophobia. The study included 112 patients (94 women, 18 men). Measurements were made before, directly after, 2 months after, and 12 months after the program. The level of work ability was rated by the patients on a scale from 0% to 100%, and kinesiophobia was measured by the Swedish version of the Tampa Scale for Kinesiophobia (TSK-SV). Kinesiophobia decreased between the start of the multimodal rehabilitation program and the follow-up periods. Work ability increased over time, but not between baseline and the 2-month follow-up. Decreases in the TSK-SV score between baseline and the 2-month follow-up were related to the increased probability of improved work ability at the 12-month follow-up. In conclusion, a decrease in kinesiophobia seems to be related to increased work ability of patients participating in a 4-week multimodal rehabilitation program.
An All-Silk-Derived Dual-Mode E-skin for Simultaneous Temperature-Pressure Detection.
Wang, Chunya; Xia, Kailun; Zhang, Mingchao; Jian, Muqiang; Zhang, Yingying
2017-11-15
Flexible skin-mimicking electronics are highly desired for development of smart human-machine interfaces and wearable human-health monitors. Human skins are able to simultaneously detect different information, such as touch, friction, temperature, and humidity. However, due to the mutual interferences of sensors with different functions, it is still a big challenge to fabricate multifunctional electronic skins (E-skins). Herein, a combo temperature-pressure E-skin is reported through assembling a temperature sensor and a strain sensor in both of which flexible and transparent silk-nanofiber-derived carbon fiber membranes (SilkCFM) are used as the active material. The temperature sensor presents high temperature sensitivity of 0.81% per centigrade. The strain sensor shows an extremely high sensitivity with a gauge factor of ∼8350 at 50% strain, enabling the detection of subtle pressure stimuli that induce local strain. Importantly, the structure of the SilkCFM in each sensor is designed to be passive to other stimuli, enabling the integrated E-skin to precisely detect temperature and pressure at the same time. It is demonstrated that the E-skin can detect and distinguish exhaling, finger pressing, and spatial distribution of temperature and pressure, which cannot be realized using single mode sensors. The remarkable performance of the silk-based combo temperature-pressure sensor, together with its green and large-scalable fabrication process, promising its applications in human-machine interfaces and soft electronics.
Skin temperature in the extremities of healthy and neurologically impaired children.
Svedberg, Lena E; Stener-Victorin, Elisabet; Nordahl, Gunnar; Lundeberg, Thomas
2005-01-01
Little emphasis has been accorded to peripheral skin temperature impairments in children with neurological disorders but attention has been paid to the significance of cold extremities (autonomic failure) for well-being and quality of life in adults stroke patients. Therefore, it seems important to investigate skin temperature in children with neurological disorder, especially when their communication is impaired. In the present study, we wanted to objectively verify any skin temperature differences between pre-school children with and without neurological disorders and also ascertain if any correlation existed between skin temperature and physical activity. Skin temperatures in 25 healthy children and 15 children with cerebral or spinal cord damages were assessed using infrared radiation. The temperatures were recorded on the palm and the dorsal surface of the hands and on the sole and dorsal surface of the feet three times at 15-minute intervals over 30min. A significant lower mean skin temperature in all measurement points was seen in non-walking children with cerebral damages compared to healthy controls. Also, the mean skin temperature was significantly lower in all foot measuring points in the children with cerebral damages that were unable to walk compared to those walking. In conclusion, as cold extremities may result in impaired well-being and hypothetically may be associated with other symptoms born by the child, further investigations of thermal dysfunction and autonomic function are of importance and treatment may be warranted.
Hodges, Gary J.; Johnson, John M.
2015-01-01
The vascular response to local skin cooling is dependent in part on a cold-induced translocation of α2C-receptors and an increased α-adrenoreceptor function. To discover whether β-adrenergic function might contribute, we examined whether β-receptor sensitivity to the β-agonist isoproterenol was affected by local skin temperature. In seven healthy volunteers, skin blood flow was measured from the forearm by laser-Doppler flowmetry and blood pressure was measured by finger photoplethysmography. Data were expressed as cutaneous vascular conductance (CVC; laser-Doppler flux/mean arterial blood pressure). Pharmacological agents were administered via intradermal microdialysis. We prepared four skin sites: one site was maintained at a thermoneutral temperature of 34°C (32 ± 10%CVCmax) one site was heated to 39°C (38 ± 11%CVCmax); and two sites were cooled, one to 29°C (22 ± 7%CVCmax) and the other 24°C (16 ± 4%CVCmax). After 20 min at these temperatures to allow stabilization of skin blood flow, isoproterenol was perfused in concentrations of 10, 30, 100, and 300 μM. Each concentration was perfused for 15 min. Relative to the CVC responses to isoproterenol at the thermoneutral skin temperature (34°C) (+21 ± 10%max), low skin temperatures reduced (at 29°C) (+17 ± 6%max) or abolished (at 24°C) (+1 ± 5%max) the vasodilator response, and warm (39°C) skin temperatures enhanced the vasodilator response (+40 ± 9%max) to isoproterenol. These data indicate that β-adrenergic function was influenced by local skin temperature. This finding raises the possibility that a part of the vasoconstrictor response to direct skin cooling could include reduced background β-receptor mediated vasodilation. PMID:25701007
Hodges, Gary J; Kellogg, Dean L; Johnson, John M
2015-04-01
The vascular response to local skin cooling is dependent in part on a cold-induced translocation of α2C-receptors and an increased α-adrenoreceptor function. To discover whether β-adrenergic function might contribute, we examined whether β-receptor sensitivity to the β-agonist isoproterenol was affected by local skin temperature. In seven healthy volunteers, skin blood flow was measured from the forearm by laser-Doppler flowmetry and blood pressure was measured by finger photoplethysmography. Data were expressed as cutaneous vascular conductance (CVC; laser-Doppler flux/mean arterial blood pressure). Pharmacological agents were administered via intradermal microdialysis. We prepared four skin sites: one site was maintained at a thermoneutral temperature of 34°C (32 ± 10%CVCmax) one site was heated to 39°C (38 ± 11%CVCmax); and two sites were cooled, one to 29°C (22 ± 7%CVCmax) and the other 24°C (16 ± 4%CVCmax). After 20 min at these temperatures to allow stabilization of skin blood flow, isoproterenol was perfused in concentrations of 10, 30, 100, and 300 μM. Each concentration was perfused for 15 min. Relative to the CVC responses to isoproterenol at the thermoneutral skin temperature (34°C) (+21 ± 10%max), low skin temperatures reduced (at 29°C) (+17 ± 6%max) or abolished (at 24°C) (+1 ± 5%max) the vasodilator response, and warm (39°C) skin temperatures enhanced the vasodilator response (+40 ± 9%max) to isoproterenol. These data indicate that β-adrenergic function was influenced by local skin temperature. This finding raises the possibility that a part of the vasoconstrictor response to direct skin cooling could include reduced background β-receptor mediated vasodilation. Copyright © 2015 the American Physiological Society.
Martinez-Tellez, Borja; Sanchez-Delgado, Guillermo; Acosta, Francisco M; Alcantara, Juan M A; Boon, Mariëtte R; Rensen, Patrick C N; Ruiz, Jonatan R
2017-09-05
Cold exposure is necessary to activate human brown adipose tissue (BAT), resulting in heat production. Skin temperature is an indirect measure to monitor the body's reaction to cold. The aim of this research was to study whether the most used equations to estimate parameters of skin temperature in BAT-human studies measure the same values of temperature in young lean men (n = 11: 23.4 ± 0.5 years, fat mass: 19.9 ± 1.2%). Skin temperature was measured with 26 ibuttons at 1-minute intervals in warm and cold room conditions. We used 12 equations to estimate parameters of mean, proximal, and distal skin temperature as well as skin temperature gradients. Data were analysed with Temperatus software. Significant differences were found across equations to measure the same parameters of skin temperature in warm and cold room conditions, hampering comparison across studies. Based on these findings, we suggest to use a set of 14 ibuttons at anatomical positions reported by ISO STANDARD 9886:2004 plus five ibuttons placed on the right supraclavicular fossa, right middle clavicular bone, right middle upper forearm, right top of forefinger, and right upper chest.
Skin temperature changes induced by strong static magnetic field exposure.
Ichioka, Shigeru; Minegishi, Masayuki; Iwasaka, Masakazu; Shibata, Masahiro; Nakatsuka, Takashi; Ando, Joji; Ueno, Shoogo
2003-09-01
High intensity static magnetic fields, when applied to the whole body of the anesthetized rat, have previously been reported to decrease skin temperature. The hypothesis of the present study was that in diamagnetic water, molecules in the air play significant roles in the mechanism of skin temperature decrease. We used a horizontal cylindrical superconducting magnet. The magnet produced 8 T at its center. A thermistor probe was inserted in a subcutaneous pocket of the anesthetized rats to measure skin temperature. Animals (n=10) were placed in an open plastic holder in which the ambient air was free to move in any direction (group I). Animals (n=10) were placed in a closed holder in which the air circulation toward the direction of weak magnetic field was restricted (group II). Each holder was connected to a hydrometer to measure humidity around the animal in the holder. The data acquisition phase consisted of a 5 min baseline interval, followed by inserting the animal together with the holder into the center of the magnet bore for a 5 min exposure and a 5 min postexposure period outside the bore. In group I, skin temperature and humidity around the animal significantly decreased during exposure, followed by recovery after exposure. In group II, skin temperature and humidity did not decrease during the measurement. The skin temperature decrease was closely related to the decrease in humidity around the body of the animal in the holder, and the changes were completely blocked by restricting the air circulation in the direction of the bore entrance. Possible mechanisms responsible for the decrease in skin temperature may be associated with magnetically induced movement of water vapor at the skin surface, leading to skin temperature decrease. Copyright 2003 Wiley-Liss, Inc.
Effect of skin temperature on the cholinergic sensitivity of the human eccrine sweat gland.
DiPasquale, Dana M; Buono, Michael J; Kolkhorst, Fred W
2003-12-01
Although sweat gland activity is directly controlled by the central nervous system, which detects changes in core body temperature, sweat glands can also be influenced by local cutaneous thermal conditions. The present study sought to determine the effect of local skin temperature on pilocarpine-induced sweating within a range of typical skin temperatures. Thirteen subjects (30 +/- 6 years; 172 +/- 11 cm; 72.8 +/- 11.0 kg) had forearm sweat rates measured at rest following pilocarpine iontophoresis at each of three skin temperatures in randomized order: warm (T(warm) = 37.1 +/- 0.9 degrees C), control (T(con) = 32.3 +/- 1.4 degrees C), and cool (T(cool) = 26.6 +/- 1.3 degrees C). T(skin) was raised and lowered with an electric heating pad and gel ice pack, respectively. Forearm T(skin) was measured with a skin temperature probe. Pilocarpine iontophoresis was used on an approximately 7 cm(2) area of the anterior forearm to stimulate localized sweating. Following stimulation, sweat was collected from the area for 15 min with a Macroduct Sweat Collection System. There was a higher sweat rate at T(warm) (p = 0.001) and T(con) (p = 0.006) compared to that at T(cool). However, there was no difference between the sweat rate at T(warm) and that at T(con) (p = 0.127). These results indicated that skin temperatures below approximately 32 degrees C affect local sweat production primarily by altering glandular sensitivity to the neurotransmitter, whereas skin temperatures above approximately 32 degrees C predominantly affect neurotransmitter release. Furthermore, sweat glands display maximal or near maximal cholinergic sensitivity at resting skin temperature in a thermoneutral environment.
Segal, Ava D; Klute, Glenn K
2016-01-01
Thermal comfort remains a common problem for people with lower-limb amputation. Both donning a prosthesis and engaging in activity at room temperature can increase residual limb skin temperature; however, the effects of activity on skin temperature and comfort in more extreme environments remain unknown. We examined residual limb skin temperatures and perceived thermal comfort (PTC; 11-point Likert scale) of participants with unilateral transtibial amputation (n = 8) who were snowshoeing in a cold environment. Residual limb skin temperature increased by 3.9°C [3.0°C to 4.7°C] (mean difference [95% confidence interval (CI)], p < 0.001) after two 30 min exercise sessions separated by a 5 min rest session. Minimal cooling (-0.2°C [-1.1°C to 0.6°C]) occurred during the rest period. Similar changes in PTC were found for the residual limb, intact limb, and whole body, with a mean scale increase of 1.6 [1.1 to 2.1] and 1.3 [0.8 to 1.8] for the first and second exercise sessions, respectively (p < 0.001). Activity in a cold environment caused similar increases in residual limb skin temperature as those found in studies conducted at room temperature. Participants with amputation perceived warming as their skin temperature increased during exercise followed by the perception of cooling during rest, despite minimal associated decreases in skin temperature.
High Skin Temperature and Hypohydration Impair Aerobic Performance
2012-01-01
hypohydration) in impairing submaximal aerobic performance. Hot skin is associated with high skin blood flow requirements and hypohydration is...the aerobic performance impairment (-1.5% for each l°C skin temperature). We conclude that hot skin ( high skin blood flow requirements from narrow...associated with high skin blood flow requirements and hypohydration is associated with reduced cardiac filling, both of which act to reduce aerobic
Remote kinematic training for patients with chronic neck pain: a randomised controlled trial.
Sarig Bahat, Hilla; Croft, Kate; Carter, Courtney; Hoddinott, Anna; Sprecher, Elliot; Treleaven, Julia
2018-06-01
To evaluate short- and intermediate-term effects of kinematic training (KT) using virtual reality (VR) or laser in patients with chronic neck pain. A randomised controlled trial with three arms (laser, VR, control) to post-intervention (N = 90), and two arms (laser or VR) continuing to 3 months follow-up. Home training intervention was provided during 4 weeks to VR and laser groups while control group waited. Primary outcome measures included neck disability index (NDI), global perceived effect (GPE), and cervical motion velocity (mean and peak). Secondary outcome measures included pain intensity (VAS), health status (EQ5D), kinesiophobia (TSK), range, smoothness, and accuracy of neck motion as measured by the neck VR system. Measures were taken at baseline, immediately post-training, and 3 months later. Ninety patients with neck pain were randomised to the trial, of which 76 completed 1 month follow-up, and 56 the 3 months follow-up. Significant improvements were demonstrated in NDI and velocity with good effect sizes in intervention groups compared to control. No within-group changes were presented in the control group, compared to global improvements in intervention groups. Velocity significantly improved at both time points in both groups. NDI, VAS, EQ5D, TSK and accuracy significantly improved at both time points in VR and in laser at 3 months evaluation in all but TSK. GPE scores showed 74-84% of participants perceived improvement and/or were satisfied. Significant advantages to the VR group compared to laser were found in velocity, pain intensity, health status and accuracy at both time points. The results support home kinematic training using VR or laser for improving disability, neck pain and kinematics in the short and intermediate term with an advantage to the VR group. The results provide directions for future research, use and development. ACTRN12615000231549.
Fear of Movement Is Related to Trunk Stiffness in Low Back Pain
Karayannis, Nicholas V.; Smeets, Rob J. E. M.; van den Hoorn, Wolbert; Hodges, Paul W.
2013-01-01
Background Psychological features have been related to trunk muscle activation patterns in low back pain (LBP). We hypothesised higher pain-related fear would relate to changes in trunk mechanical properties, such as higher trunk stiffness. Objectives To evaluate the relationship between trunk mechanical properties and psychological features in people with recurrent LBP. Methods The relationship between pain-related fear (Tampa Scale for Kinesiophobia, TSK; Photograph Series of Daily Activities, PHODA-SeV; Fear Avoidance Beliefs Questionnaire, FABQ; Pain Catastrophizing Scale, PCS) and trunk mechanical properties (estimated from the response of the trunk to a sudden sagittal plane forwards or backwards perturbation by unpredictable release of a load) was explored in a case-controlled study of 14 LBP participants. Regression analysis (r 2) tested the linear relationships between pain-related fear and trunk mechanical properties (trunk stiffness and damping). Mechanical properties were also compared with t-tests between groups based on stratification according to high/low scores based on median values for each psychological measure. Results Fear of movement (TSK) was positively associated with trunk stiffness (but not damping) in response to a forward perturbation (r2 = 0.33, P = 0.03), but not backward perturbation (r2 = 0.22, P = 0.09). Other pain-related fear constructs (PHODA-SeV, FABQ, PCS) were not associated with trunk stiffness or damping. Trunk stiffness was greater for individuals with high kinesiophobia (TSK) for forward (P = 0.03) perturbations, and greater with forward perturbation for those with high fear avoidance scores (FABQ-W, P = 0.01). Conclusions Fear of movement is positively (but weakly) associated with trunk stiffness. This provides preliminary support an interaction between biological and psychological features of LBP, suggesting this condition may be best understood if these domains are not considered in isolation. PMID:23826339
Formenti, Damiano; Ludwig, Nicola; Gargano, Marco; Bosio, Andrea; Rampinini, Ermanno; Alberti, Giampietro
2018-01-01
Although moderate relationships (|r| ∼ 0.5) were reported between skin temperature and performance-related variables (e.g., kinetic), it remains unclear whether skin temperature asymmetry reflects muscle force imbalance in cycling. Therefore, the aim of this study was to assess whether a relationship exists between kinetic and thermal asymmetry during a fatiguing exercise. Ten elite cyclists were enrolled and tested on a maximal incremental cycling test. Peak crank torques of both legs were obtained at the initial and final workload. Likewise, bilateral skin temperatures were recorded before and after exercise. Asymmetric indexes were also calculated for kinetic (AIK) and skin temperature (AIT) outcomes. The bilateral peak crank torques showed a larger difference at the final compared to the initial workload (p < 0.05) of the incremental exercise. Conversely, the bilateral skin temperature did not show any differences at both initial and final workload (p > 0.05). Additionally, trivial relationships were reported between AIK and AIT (−0.3 < r < 0.2) at the initial and final workload. The obtained results showed that changes in bilateral kinetic values did not reflect concurrent changes in bilateral skin temperatures. This finding emphasizes the difficulty of associating the asymmetry of skin temperature with those of muscle effort in elite cyclists. Lastly, our study also provided further insights on thermal skin responses during exhaustive cycling exercise in very highly-trained athletes. PMID:29507831
Thomas, Karen A; Burr, Robert; Wang, Shu-Yuann; Lentz, Martha J; Shaver, Joan
2004-01-01
Data from 2 separate studies were used to examine the relationships of axillary or thoracic skin temperature to rectal temperature and to determine the phase relationships of the circadian rhythms of these temperatures. In study 1, axillary skin and rectal temperatures were recorded in 19 healthy women, 21 to 36 years of age. In study 2, thoracic skin and rectal temperatures were recorded in 74 healthy women, 39 to 59 years of age. In both studies, temperatures were recorded continuously for 24 h while subjects carried out normal activities. Axillary and thoracic probes were insulated purposely to prevent ambient effects. Cosinor analysis was employed to estimate circadian rhythm mesor, amplitude, and acrophase. In addition, correlations between temperatures at various measurement sites were calculated and agreement determined. The circadian timing of axillary and skin temperature did not closely approximate that of rectal temperature: the mean acrophase (clock time) for study 1 was 18:57 h for axillary temperature and 16:12 h for rectal; for study 2, it was 03:05 h for thoracic and 15:05 h for rectal. Across individual subjects, the correlations of axillary or thoracic temperatures with rectal temperatures were variable. Results do not support the use of either axillary or skin temperature as a substitute for rectal temperature in circadian rhythm research related to adult women.
Oh, Ju Hyun; Hong, Soo Yeong; Park, Heun; Jin, Sang Woo; Jeong, Yu Ra; Oh, Seung Yun; Yun, Junyeong; Lee, Hanchan; Kim, Jung Wook; Ha, Jeong Sook
2018-02-28
In this study, we demonstrate the fabrication of a highly sensitive flexible temperature sensor with a bioinspired octopus-mimicking adhesive. A resistor-type temperature sensor consisting of a composite of poly(N-isopropylacrylamide) (pNIPAM)-temperature sensitive hydrogel, poly(3,4-ethylenedioxythiophene) polystyrene sulfonate, and carbon nanotubes exhibits a very high thermal sensitivity of 2.6%·°C -1 between 25 and 40 °C so that the change in skin temperature of 0.5 °C can be accurately detected. At the same time, the polydimethylsiloxane adhesive layer of octopus-mimicking rim structure coated with pNIPAM is fabricated through the formation of a single mold by utilizing undercut phenomenon in photolithography. The fabricated sensor shows stable and reproducible detection of skin temperature under repeated attachment/detachment cycles onto skin without any skin irritation for a long time. This work suggests a high potential application of our skin-attachable temperature sensor to wearable devices for medical and health-care monitoring.
Thomas, K A; Burr, R
1999-06-01
Incubator thermal environments produced by skin versus air servo-control were compared. Infant abdominal skin and incubator air temperatures were recorded from 18 infants in skin servo-control and 14 infants in air servo-control (26- to 29-week gestational age, 14 +/- 2 days postnatal age) for 24 hours. Differences in incubator and infant temperature, neutral thermal environment (NTE) maintenance, and infant and incubator circadian rhythm were examined using analysis of variance and scatterplots. Skin servo-control resulted in more variable air temperature, yet more stable infant temperature, and more time within the NTE. Circadian rhythm of both infant and incubator temperature differed by control mode and the relationship between incubator and infant temperature rhythms was a function of control mode. The differences between incubator control modes extend beyond temperature stability and maintenance of NTE. Circadian rhythm of incubator and infant temperatures is influenced by incubator control.
Effect of ambient temperature on the thermal profile of the human forearm, hand, and fingers
NASA Technical Reports Server (NTRS)
Montgomery, L. D.; Williams, B. A.
1976-01-01
Forearm, hand, and finger skin temperatures were measured on the right and left sides of seven resting men. The purpose was to determine the bilateral symmetry of these segmental temperature profiles at ambient temperatures from 10 to 45 C. Thermistors placed on the right and left forearms, hands, and index fingers were used to monitor the subjects until equilibration was reached at each ambient temperature. Additionally, thermal profiles of both hands were measured with copper-constantan thermocouples. During one experimental condition (23 C ambient), rectal, ear canal, and 24 skin temperatures were measured on each subject. Average body and average skin temperatures are given for each subject at the 23 C ambient condition. Detailed thermal profiles are also presented for the dorsal, ventral, and circumferential left forearm, hand, and finger skin temperatures at 23 C ambient. No significant differences were found between the mean skin temperatures of the right and left contralateral segments at any of the selected ambient temperatures.
Toward a fuzzy logic control of the infant incubator.
Reddy, Narender P; Mathur, Garima; Hariharan, S I
2009-10-01
Premature birth is a world wide problem. Thermo regulation is a major problem in premature infants. Premature infants are often kept in infant incubators providing convective heating. Currently either the incubator air temperature is sensed and used to control the heat flow, or infant's skin temperature is sensed and used in the close loop control. Skin control often leads to large fluctuations in the incubator air temperature. Air control also leads to skin temperature fluctuations. The question remains if both the infant's skin temperature and the incubator air temperature can be simultaneously used in the control. The purpose of the present study was to address this question by developing a fuzzy logic control which incorporates both incubator air temperature and infant's skin temperature to control the heating. The control was evaluated using a lumped parameter mathematical model of infant-incubator system (Simon, B. N., N. P. Reddy, and A. Kantak, J. Biomech. Eng. 116:263-266, 1994). Simulation results confirmed previous experimental results that the on-off skin control could lead to fluctuations in the incubator air temperature, and the air control could lead to too slow rise time in the core temperature. The fuzzy logic provides a smooth control with the desired rise time.
Freezing temperature of finger skin.
Wilson, O; Goldman, R F; Molnar, G W
1976-10-01
In 45 subjects, 154 frostnips of the finger were induced by cooling in air at -15 degrees C with various wind speeds. The mean supercooled skin temperature at which frostnip appeared was -9.4 degrees C. The mean skin temperature rise due to heat of fusion at ice crystallization was 5.3 degrees C. The skin temperature rose to what was termed the apparent freezing point. The relation of this point to the supercooled skin temperature was analyzed for the three wind speeds used. An apparent freezing point for a condition of no supercooling was calculated, estimating the highest temperature at which skin freezes at a given wind speed. The validity of the obtained differences in apparent freezing point was tested by an analysis of covariance. Although not statistically significant, the data suggest that the apparent freezing point with no supercooling decreases with increasing wind velocity. The highest calculated apparent freezing point at -15 degrees C and 6.8 m/s was 1.2 degrees C lower than the true freezing point for skin previously determined in brine, which is a statistically significant difference.
NASA Astrophysics Data System (ADS)
Mackaro, Scott M.; McNider, Richard T.; Biazar, Arastoo Pour
2012-03-01
Skin temperatures that reflect the radiating temperature of a surface observed by infrared radiometers are one of the most widely available products from polar orbiting and geostationary satellites and the most commonly used satellite data in land surface assimilation. Past work has indicated that a simple land surface scheme with a few key parameters constrained by observations such as skin temperatures may be preferable to complex land use schemes with many unknown parameters. However, a true radiating skin temperature is sometimes not a prognostic variable in weather forecast models. Additionally, recent research has shown that skin temperatures cannot be directly used in surface similarity forms for inferring fluxes. This paper examines issues encountered in using satellite derived skin temperatures to improve surface flux specifications in weather forecast and air quality models. Attention is given to iterations necessary when attempting to nudge the surface energy budget equation to a desired state. Finally, the issue of mathematical operator splitting is examined in which the surface energy budget calculations are split with the atmospheric vertical diffusion calculations. However, the high level of connectivity between the surface and first atmospheric level means that the operator splitting leads to high frequency oscillations. These oscillations may hinder the assimilation of skin temperature derived moisture fluxes.
A modeling study on the influence of blood flow regulation on skin temperature pulsations
NASA Astrophysics Data System (ADS)
Tang, Yanliang; Mizeva, Irina; He, Ying
2017-04-01
Nowadays together with known optic techniques of microcirculation blood flow monitoring, skin temperature measurements are developed as well. In this paper, a simple one-dimensional bioheat transfer model was developed to analyse the heat wave transport in biological tissue, where an arteriole vessel with pulsatile blood is located. The simulated results show that the skin temperature oscillation amplitudes attenuate with the increase of blood flow oscillation frequency which gives the same tendency as that in the experiments. The parameter analyses further show that the amplitude of oscillation is also influenced by oscillation amplitude of blood and effective thermal conductivity. When oscillation amplitude of blood flow and effective thermal conductivity increase, the amplitude of skin temperature oscillation increases nonlinearly. Variation of effective thermal convective influence to the time delay of the thermal wave on the skin surface and distort it. Combination of two measurement techniques: one for estimation blood flow oscillations in the microvessels and other to the skin temperature measurement can produce additional information about the skin properties.
Normal range and lateral symmetry in the skin temperature profile of pregnant women
NASA Astrophysics Data System (ADS)
Pereira, Tânia; Nogueira-Silva, Cristina; Simoes, Ricardo
2016-09-01
Body skin temperature is a useful parameter for diagnosing diseases and infrared thermography can be a powerful tool in providing important information to detect body temperature changes in a noninvasive way. The aim of this work was to study the pattern of skin temperature during pregnancy, to establish skin temperature reference values and to find correlations between these and the pregnant population characteristics. Sixty-one healthy pregnant women (mean age 30.6 ± 5.1 years) in the 8th-40th gestational week with normal pregnancies were examined in 31 regions of interest (ROI). The ROIs were defined all over the body in order to determine the most influenced by factors such as age or body mass index (BMI). The results obtained in this work highlight that in normal pregnant women the skin temperature is symmetrically distributed, with the symmetrical areas differing less than 0.5 °C , with a mean value of 0.25 ± 0.23 °C . This study identified a significant negative correlation between the BMI and temperature. Age has been shown to have great influence on the skin temperature, with a significant increase of temperature observed with age. This work explores a novel medical application of infrared thermography and provides a characterization of thermal skin profile in human pregnancy for a large set of ROIs while also evaluating the effects of age and BMI.
Infrared thermography based studies on mobile phone induced heating
NASA Astrophysics Data System (ADS)
Lahiri, B. B.; Bagavathiappan, S.; Soumya, C.; Jayakumar, T.; Philip, John
2015-07-01
Here, we report the skin temperature rise due to the absorption of radio frequency (RF) energy from three handheld mobile phones using infrared thermography technique. Experiments are performed under two different conditions, viz. when the mobile phones are placed in soft touch with the skin surface and away from the skin surface. Additionally, the temperature rise of mobile phones during charging, operation and simultaneous charging and talking are monitored under different exposure conditions. It is observed that the temperature of the cheek and ear regions monotonically increased with time during the usage of mobile phones and the magnitude of the temperature rise is higher for the mobile phone with higher specific absorption rate. The increase in skin temperature is higher when the mobile phones are in contact with the skin surface due to the combined effect of absorption of RF electromagnetic power and conductive heat transfer. The increase in the skin temperature in non-contact mode is found to be within the safety limit of 1 °C. The measured temperature rise is in good agreement with theoretical predictions. The empirical equation obtained from the temperature rise on the cheek region of the subjects correlates well with the specific absorption rate of the mobile phones. Our study suggests that the use of mobile phones in non-contact mode can significantly lower the skin temperature rise during its use and hence, is safer compared to the contact mode.
Electrocutaneous sensitivity: effects of skin temperature.
Larkin, W D; Reilly, J P
1986-01-01
The effect of human skin temperature on electrocutaneous sensitivity was examined using brief capacitive discharges. Stimuli were designed to ensure that sensory effects would be independent of skin resistance and would reflect underlying neural excitability as closely as possible. Skin temperature was manipulated by immersing the forearm in circulating hot or cold air. Detection thresholds on the arm and fingertip were raised by cooling, but were not altered by heating. Temperature-related sensitivity shifts were described by the same multiplicative factors for both threshold and suprathreshold levels. The temperature coefficient (Q10) for cutaneous sensitivity under these conditions was approximately 1.3.
Lenders, J W; Salemans, J; de Boo, T; Lemmens, W A; Thien, T; van't Laar, A
1986-03-01
A double-blind randomized study was designed to investigate differences in the recovery of finger skin temperature after finger cooling during dosing with placebo or one of four beta-blockers: propranolol, atenolol, pindolol, and acebutolol. In 11 normotensive nonsmoking subjects, finger skin temperature was measured with a thermocouple before and 20 minutes after immersion of one hand in a water bath at 16 degrees C. This finger cooling test caused no significant changes in systemic hemodynamics such as arterial blood pressure, heart rate, and forearm blood flow. The recovery of finger skin temperature during propranolol dosing was better than that during pindolol and atenolol dosing. There were no differences between the recoveries of skin temperature during pindolol, atenolol, and acebutolol dosing. Thus we could demonstrate no favorable effect of intrinsic sympathomimetic activity or beta 1-selectivity on the recovery of finger skin temperature after finger cooling.
Modeling Skin Injury from Hot Rice Porridge Spills
2018-01-01
The present work analyzes skin burns from spills of hot rice and milk products. The traditional Norwegian rice porridge serves as an example. By testing spills on objects emulating an arm, it was concluded that spills were seldom thinner than 3 mm, and stayed in place due to the viscosity of the porridge for more than one minute. The Pennes bioheat equation was solved numerically for such spills, including heat conduction to the skin and convective heat losses from the porridge surface. Temperatures were analyzed in the porridge and skin layers, and the resulting skin injury was calculated based on the basal layer temperature. Parameters influencing burn severity, such as porridge layer thickness, porridge temperature, removal of the porridge and thermal effects of post scald tempered (15 °C) water cooling were analyzed. The spilled porridge resulted in a prolonged heat supply to the skin, and the skin injury developed significantly with time. The porridge temperature turned out to be the most important injury parameter. A 70 °C porridge temperature could develop superficial partial-thickness burns. Porridge temperatures at processing temperatures nearly instantly developed severe burns. It was demonstrated that prompt removal of the hot porridge significantly reduced the injury development. The general advice is to avoid serving porridge and similar products at temperatures above 65 °C and, if spilled on the skin, to remove it quickly. After such scald incidents, it is advised to cool the injured area by tempered water for a prolonged period to stimulate healing. PMID:29677134
Du, Xiuyuan; Li, Baizhan; Liu, Hong; Yang, Dong; Yu, Wei; Liao, Jianke; Huang, Zhichao; Xia, Kechao
2014-01-01
This paper reports on studies of the effect of temperature step-change (between a cool and a neutral environment) on human thermal sensation and skin temperature. Experiments with three temperature conditions were carried out in a climate chamber during the period in winter. Twelve subjects participated in the experiments simulating moving inside and outside of rooms or cabins with air conditioning. Skin temperatures and thermal sensation were recorded. Results showed overshoot and asymmetry of TSV due to the step-change. Skin temperature changed immediately when subjects entered a new environment. When moving into a neutral environment from cool, dynamic thermal sensation was in the thermal comfort zone and overshoot was not obvious. Air-conditioning in a transitional area should be considered to limit temperature difference to not more than 5°C to decrease the unacceptability of temperature step-change. The linear relationship between thermal sensation and skin temperature or gradient of skin temperature does not apply in a step-change environment. There is a significant linear correlation between TSV and Qloss in the transient environment. Heat loss from the human skin surface can be used to predict dynamic thermal sensation instead of the heat transfer of the whole human body. PMID:25136808
The physico-chemical properties of pangas catfish (Pangasius pangasius) skin gelatin
NASA Astrophysics Data System (ADS)
Pradarameswari, K. A.; Zaelani, K.; Waluyo, E.; Nurdiani, R.
2018-04-01
Gelatin can be used as emulsifier and stabilizer in food products. Until now, the most widely used raw materials for the production of gelatin industry are cow bone, cow skin and pig skin. Fish gelatin has been highlighted as a better alternative to replace mammals gelatin based on ethical and religious perspective. Fish gelatin was extracted from Pangas catfish skin to determine its physico-chemical properties. Different temperatures (45 °C, 50 °C, 55 °C) were employed during gelatin extraction. Higher temperature increased the yield and fat contents of Pangas catfish skin gelatin. In contrary, higher water, protein, ash contents were observed during lower temperature. Temperature significantly (p < 0.05) affected the gel strength, viscosity, melting point, and gelling point of fish skin gelatin. Based on the FTIR spectrum catfish skin gelatin functional groups can be identified as N-H, O-H, C = H, C-O and C-H.
NASA Astrophysics Data System (ADS)
Gao, Li; Zhang, Yihui; Malyarchuk, Viktor; Jia, Lin; Jang, Kyung-In; Chad Webb, R.; Fu, Haoran; Shi, Yan; Zhou, Guoyan; Shi, Luke; Shah, Deesha; Huang, Xian; Xu, Baoxing; Yu, Cunjiang; Huang, Yonggang; Rogers, John A.
2014-09-01
Characterization of temperature and thermal transport properties of the skin can yield important information of relevance to both clinical medicine and basic research in skin physiology. Here we introduce an ultrathin, compliant skin-like, or ‘epidermal’, photonic device that combines colorimetric temperature indicators with wireless stretchable electronics for thermal measurements when softly laminated on the skin surface. The sensors exploit thermochromic liquid crystals patterned into large-scale, pixelated arrays on thin elastomeric substrates; the electronics provide means for controlled, local heating by radio frequency signals. Algorithms for extracting patterns of colour recorded from these devices with a digital camera and computational tools for relating the results to underlying thermal processes near the skin surface lend quantitative value to the resulting data. Application examples include non-invasive spatial mapping of skin temperature with milli-Kelvin precision (±50 mK) and sub-millimetre spatial resolution. Demonstrations in reactive hyperaemia assessments of blood flow and hydration analysis establish relevance to cardiovascular health and skin care, respectively.
Gao, Li; Zhang, Yihui; Malyarchuk, Viktor; Jia, Lin; Jang, Kyung-In; Webb, R Chad; Fu, Haoran; Shi, Yan; Zhou, Guoyan; Shi, Luke; Shah, Deesha; Huang, Xian; Xu, Baoxing; Yu, Cunjiang; Huang, Yonggang; Rogers, John A
2014-09-19
Characterization of temperature and thermal transport properties of the skin can yield important information of relevance to both clinical medicine and basic research in skin physiology. Here we introduce an ultrathin, compliant skin-like, or 'epidermal', photonic device that combines colorimetric temperature indicators with wireless stretchable electronics for thermal measurements when softly laminated on the skin surface. The sensors exploit thermochromic liquid crystals patterned into large-scale, pixelated arrays on thin elastomeric substrates; the electronics provide means for controlled, local heating by radio frequency signals. Algorithms for extracting patterns of colour recorded from these devices with a digital camera and computational tools for relating the results to underlying thermal processes near the skin surface lend quantitative value to the resulting data. Application examples include non-invasive spatial mapping of skin temperature with milli-Kelvin precision (±50 mK) and sub-millimetre spatial resolution. Demonstrations in reactive hyperaemia assessments of blood flow and hydration analysis establish relevance to cardiovascular health and skin care, respectively.
Supraclavicular skin temperature as a measure of 18F-FDG uptake by BAT in human subjects.
Boon, Mariëtte R; Bakker, Leontine E H; van der Linden, Rianne A D; Pereira Arias-Bouda, Lenka; Smit, Frits; Verberne, Hein J; van Marken Lichtenbelt, Wouter D; Jazet, Ingrid M; Rensen, Patrick C N
2014-01-01
Brown adipose tissue (BAT) has emerged as a novel player in energy homeostasis in humans and is considered a potential new target for combating obesity and related diseases. The current 'gold standard' for quantification of BAT volume and activity is cold-induced 18F-FDG uptake in BAT. However, use of this technique is limited by cost and radiation exposure. Given the fact that BAT is a thermogenic tissue, mainly located in the supraclavicular region, the aim of the current study was to investigate whether cold-induced supraclavicular skin temperature and core body temperature may be alternative markers of BAT activation in humans. BAT volume and activity were measured in 24 healthy lean adolescent males (mean age 24.1±0.8 years), using cold-induced 18F-FDG uptake with PET-CT. Core body temperature was measured continuously in the small intestine with use of an ingestible telemetric capsule and skin temperature was measured by eighteen wireless iButtons attached to the skin following ISO-defined locations. Proximal and distal (hand/feet) skin temperatures markedly decreased upon cold exposure, while supraclavicular skin temperature significantly increased (35.2±0.1 vs. 35.5±0.1°C, p = 0.001). Furthermore, cold-induced supraclavicular skin temperature positively correlated with both total (R2 = 0.28, P = 0.010) and clavicular BAT volume (R2 = 0.20, P = 0.030) and clavicular SUVmax (R2 = 0.27, P = 0.010), while core body temperature did not. Supraclavicular skin temperature as measured by iButtons may have predictive value for BAT detection in adult humans. This is highly desirable considering the increasing interest in pharmacological interventions to stimulate BAT in human subjects. NTR 2473.
Beyond the classic thermoneutral zone
Kingma, Boris RM; Frijns, Arjan JH; Schellen, Lisje; van Marken Lichtenbelt, Wouter D
2014-01-01
The thermoneutral zone is defined as the range of ambient temperatures where the body can maintain its core temperature solely through regulating dry heat loss, i.e., skin blood flow. A living body can only maintain its core temperature when heat production and heat loss are balanced. That means that heat transport from body core to skin must equal heat transport from skin to the environment. This study focuses on what combinations of core and skin temperature satisfy the biophysical requirements of being in the thermoneutral zone for humans. Moreover, consequences are considered of changes in insulation and adding restrictions such as thermal comfort (i.e. driver for thermal behavior). A biophysical model was developed that calculates heat transport within a body, taking into account metabolic heat production, tissue insulation, and heat distribution by blood flow and equates that to heat loss to the environment, considering skin temperature, ambient temperature and other physical parameters. The biophysical analysis shows that the steady-state ambient temperature range associated with the thermoneutral zone does not guarantee that the body is in thermal balance at basal metabolic rate per se. Instead, depending on the combination of core temperature, mean skin temperature and ambient temperature, the body may require significant increases in heat production or heat loss to maintain stable core temperature. Therefore, the definition of the thermoneutral zone might need to be reformulated. Furthermore, after adding restrictions on skin temperature for thermal comfort, the ambient temperature range associated with thermal comfort is smaller than the thermoneutral zone. This, assuming animals seek thermal comfort, suggests that thermal behavior may be initiated already before the boundaries of the thermoneutral zone are reached. PMID:27583296
2013-01-01
Background The aim of the study was to evaluate the performance of contact heat thermal stimulation in horses at different body sites and under different environmental conditions and different test situations. Five warm-blood horses were equipped with the thermal probe located on the skin of nostril (N), withers (W) or coronary band (C). Skin temperature and reaction temperature (thermal threshold) at each location were measured and percent thermal excursion (% TE = 100 * (threshold temperature - skin temperature)/(cut-out temperature - skin temperature) was calculated. Environmental conditions were changed in partial random order for all locations, so each horse was tested in its familiar box stall and stocks, in the morning and evening and at warm and cold ambient temperatures. Type of reaction to the stimulus and horse’s general behaviour during stimulation were recorded. The stimulation sites were examined for the occurrence of possible skin lesions. Results Skin temperatures were significantly different during warm and cold ambient temperatures at all three locations, but remained constant over repeated stimulation. An obvious response to stimulation before reaching cut-out temperature could be detected most frequently at N and W in boxes during warm ambient temperatures. The most frequent type of reaction to thermal stimulation at the nostril was headshaking (64.6%), skin twitching at the withers (82.9%) and hoof withdrawal at the coronary band (79.2%). Conclusion The outcome of thermal threshold testing depended on ambient temperature, stimulation site and environment. Best results with the WTT2 in horses were obtained at the nostrils or withers in a familiar environment at warm ambient temperatures. PMID:23298405
Beyond the classic thermoneutral zone: Including thermal comfort.
Kingma, Boris Rm; Frijns, Arjan Jh; Schellen, Lisje; van Marken Lichtenbelt, Wouter D
2014-01-01
The thermoneutral zone is defined as the range of ambient temperatures where the body can maintain its core temperature solely through regulating dry heat loss, i.e., skin blood flow. A living body can only maintain its core temperature when heat production and heat loss are balanced. That means that heat transport from body core to skin must equal heat transport from skin to the environment. This study focuses on what combinations of core and skin temperature satisfy the biophysical requirements of being in the thermoneutral zone for humans. Moreover, consequences are considered of changes in insulation and adding restrictions such as thermal comfort (i.e. driver for thermal behavior). A biophysical model was developed that calculates heat transport within a body, taking into account metabolic heat production, tissue insulation, and heat distribution by blood flow and equates that to heat loss to the environment, considering skin temperature, ambient temperature and other physical parameters. The biophysical analysis shows that the steady-state ambient temperature range associated with the thermoneutral zone does not guarantee that the body is in thermal balance at basal metabolic rate per se. Instead, depending on the combination of core temperature, mean skin temperature and ambient temperature, the body may require significant increases in heat production or heat loss to maintain stable core temperature. Therefore, the definition of the thermoneutral zone might need to be reformulated. Furthermore, after adding restrictions on skin temperature for thermal comfort, the ambient temperature range associated with thermal comfort is smaller than the thermoneutral zone. This, assuming animals seek thermal comfort, suggests that thermal behavior may be initiated already before the boundaries of the thermoneutral zone are reached.
Poller, Christin; Hopster, Klaus; Rohn, Karl; Kästner, Sabine Br
2013-01-08
The aim of the study was to evaluate the performance of contact heat thermal stimulation in horses at different body sites and under different environmental conditions and different test situations. Five warm-blood horses were equipped with the thermal probe located on the skin of nostril (N), withers (W) or coronary band (C). Skin temperature and reaction temperature (thermal threshold) at each location were measured and percent thermal excursion (% TE = 100 * (threshold temperature - skin temperature)/(cut-out temperature - skin temperature) was calculated. Environmental conditions were changed in partial random order for all locations, so each horse was tested in its familiar box stall and stocks, in the morning and evening and at warm and cold ambient temperatures. Type of reaction to the stimulus and horse's general behaviour during stimulation were recorded. The stimulation sites were examined for the occurrence of possible skin lesions. Skin temperatures were significantly different during warm and cold ambient temperatures at all three locations, but remained constant over repeated stimulation. An obvious response to stimulation before reaching cut-out temperature could be detected most frequently at N and W in boxes during warm ambient temperatures. The most frequent type of reaction to thermal stimulation at the nostril was headshaking (64.6%), skin twitching at the withers (82.9%) and hoof withdrawal at the coronary band (79.2%). The outcome of thermal threshold testing depended on ambient temperature, stimulation site and environment. Best results with the WTT2 in horses were obtained at the nostrils or withers in a familiar environment at warm ambient temperatures.
Thermoregulatory control of finger blood flow
NASA Technical Reports Server (NTRS)
Wenger, C. B.; Roberts, M. F.; Nadel, E. R.; Stolwijk, J. A. J.
1975-01-01
In the present experiment, exercise was used to vary internal temperature and ambient air heat control was used to vary skin temperature. Finger temperature was fixed at about 35.7 C. Esophageal temperature was measured with a thermocouple at the level of the left atrium, and mean skin temperature was calculated from a weighted mean of thermocouple temperatures at different skin sites. Finger blood flow was measured by electrocapacitance plethysmography. An equation in these quantities is given which accounts for the data garnered.
Effects of pressure, cold and gloves on hand skin temperature and manual performance of divers.
Zander, Joanna; Morrison, James
2008-09-01
Cold water immersion and protective gloves are associated with decreased manual performance. Although neoprene gloves slow hand cooling, there is little information on whether they provide sufficient protection when diving in cold water. Nine divers wearing three-fingered neoprene gloves and dry suits were immersed in water at 25 and 4 degrees C, at depths of 0.4 msw (101 kPa altitude adjusted) and 40 msw (497 kPa) in a hyperbaric chamber. Skin temperatures were measured at the fingers, hand, forearm, chest and head. Grip strength, tactile sensitivity and manual dexterity were measured at three time intervals. There was an exponential decay in finger and back of hand skin temperatures with exposure time in 4 degrees C water. Finger and back of hand skin temperatures were lower at 40 msw than at 0.4 msw (P < 0.05). There was no effect of pressure or temperature on grip strength. Tactile sensitivity decreased linearly with finger skin temperature at both pressures. Manual dexterity was not affected by finger skin temperature at 0.4 msw, but decreased with fall in finger skin temperature at 40 msw. Results show that neoprene gloves do not provide adequate thermal protection in 4 degrees C water and that impairment of manual performance is dependent on the type of task, depth and exposure time.
Temperature Control in a Franz Diffusion Cell Skin Sonoporation Setup
NASA Astrophysics Data System (ADS)
Robertson, Jeremy; Becker, Sid
2017-11-01
In vitro experimental studies that investigate ultrasound enhanced transdermal drug delivery employ Franz diffusion cells. Because of absorption, the temperature of the coupling fluid often increases drastically during the ultrasound application. The current methodologies for controlling the coupling fluid temperature require either replacement of the coupling fluid during the experiment or the application of a time consuming duty cycle. This paper introduces a novel method for temperature control that allows for a wide variety of coupling fluid temperatures to be maintained. This method employs a peristaltic pump to circulate the coupling fluid through a thermoelectric cooling device. This temperature control method allowed for an investigation into the role of coupling fluid temperature on the inertial cavitation that impacts the skin aperture (inertial cavitation is thought to be the main cause of ultrasound induced skin permeability increase). Both foil pitting and passive cavitation detection experiments indicated that effective inertial cavitation activity decreases with increasing coupling fluid temperature. This finding suggests that greater skin permeability enhancement can be achieved if a lower coupling fluid temperature is maintained during skin insonation.
Mori, Hidetoshi; Kuge, Hiroshi; Tanaka, Tim Hideaki; Taniwaki, Eiichi; Ohsawa, Hideo
2011-06-01
To determine whether any difference exists in responses to indirect moxibustion (IM) relative to thermal stimulation duration. In experiment 1, 9 subjects attended two experimental sessions consisting of single stimulation with IM or triple stimulation with IM, using a crossover design. A K-type thermocouple temperature probe was fixed on the skin surface at the GV14 acupuncture point. IM stimulation was administered to the top of the probe in order to measure the temperature curve. In addition, each subject evaluated his or her subjective feeling of heat on a visual analogue scale after each stimulation. Experiment 2 was conducted on 42 participants, divided into three groups according to the envelope allocation method: single stimulation with IM (n=20), triple stimulation with IM (n=11) and a control group (n=11). A thermograph was used to obtain the skin temperature on the posterior trunk of the participant. To analyse skin temperature, four arbitrary frames (the scapular, interscapular, lumbar and vertebral regions) were made on the posterior trunk. In experiment 1, no significant difference in maximum temperature was found in IM and subjective feeling of heat intensity between single and triple stimulation with IM. In experiment 2, increases in skin temperature occurred on the posterior trunk, but no differences in skin temperature occurred between the groups receiving single and triple stimulation with IM. No difference exists in the skin temperature response to moxibustion between the single and triple stimulation with IM.
Thermal Skin Damage During Reirradiation and Hyperthermia Is Time-Temperature Dependent
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bakker, Akke, E-mail: akke.bakker@amc.uva.nl; Kolff, M. Willemijn; Holman, Rebecca
Purpose: To investigate the relationship of thermal skin damage (TSD) to time–temperature isoeffect levels for patients with breast cancer recurrence treated with reirradiation plus hyperthermia (reRT + HT), and to investigate whether the treatment history of previous treatments (scar tissue) is a risk factor for TSD. Methods and Materials: In this observational study, temperature characteristics of hyperthermia sessions were analyzed in 262 patients with recurrent breast cancer treated in the AMC between 2010 and 2014 with reirradiation and weekly hyperthermia for 1 hour. Skin temperature was measured using a median of 42 (range, 29-82) measurement points per hyperthermia session. Results: Sixty-eight patients (26%) developed 79more » sites of TSD, after the first (n=26), second (n=17), third (n=27), and fourth (n=9) hyperthermia session. Seventy percent of TSD occurred on or near scar tissue. Scar tissue reached higher temperatures than other skin tissue (0.4°C, P<.001). A total of 102 measurement points corresponded to actual TSD sites in 35 of 79 sessions in which TSD developed. Thermal skin damage sites had much higher maximum temperatures than non-TSD sites (2.8°C, P<.001). Generalized linear mixed models showed that the probability of TSD is related to temperature and thermal dose values (P<.001) and that scar tissue is more at risk (odds ratio 0.4, P<.001). Limiting the maximum temperature of a measurement point to 43.7°C would mean that the probability of observing TSD was at most 5%. Conclusion: Thermal skin damage during reRT + HT for recurrent breast cancer was related to higher local temperatures and time–temperature isoeffect levels. Scar tissue reached higher temperatures than other skin tissue, and TSD occurred at lower temperatures and thermal dose values in scar tissue compared with other skin tissue. Indeed, TSD developed often on and around scar tissue from previous surgical procedures.« less
Method and apparatus to measure the depth of skin burns
Dickey, Fred M.; Holswade, Scott C.
2002-01-01
A new device for measuring the depth of surface tissue burns based on the rate at which the skin temperature responds to a sudden differential temperature stimulus. This technique can be performed without physical contact with the burned tissue. In one implementation, time-dependent surface temperature data is taken from subsequent frames of a video signal from an infrared-sensitive video camera. When a thermal transient is created, e.g., by turning off a heat lamp directed at the skin surface, the following time-dependent surface temperature data can be used to determine the skin burn depth. Imaging and non-imaging versions of this device can be implemented, thereby enabling laboratory-quality skin burn depth imagers for hospitals as well as hand-held skin burn depth sensors the size of a small pocket flashlight for field use and triage.
Khoshnevis, Sepideh; Craik, Natalie K; Matthew Brothers, R; Diller, Kenneth R
2016-03-01
The goal of this study was to investigate the persistence of cold-induced vasoconstriction following cessation of active skin-surface cooling. This study demonstrates a hysteresis effect that develops between skin temperature and blood perfusion during the cooling and subsequent rewarming period. An Arctic Ice cryotherapy unit (CTU) was applied to the knee region of six healthy subjects for 60 min of active cooling followed by 120 min of passive rewarming. Multiple laser Doppler flowmetry perfusion probes were used to measure skin blood flow (expressed as cutaneous vascular conductance (CVC)). Skin surface cooling produced a significant reduction in CVC (P < 0.001) that persisted throughout the duration of the rewarming period. In addition, there was a hysteresis effect between CVC and skin temperature during the cooling and subsequent rewarming cycle (P < 0.01). Mixed model regression (MMR) showed a significant difference in the slopes of the CVC-skin temperature curves during cooling and rewarming (P < 0.001). Piecewise regression was used to investigate the temperature thresholds for acceleration of CVC during the cooling and rewarming periods. The two thresholds were shown to be significantly different (P = 0.003). The results show that localized cooling causes significant vasoconstriction that continues beyond the active cooling period despite skin temperatures returning toward baseline values. The significant and persistent reduction in skin perfusion may contribute to nonfreezing cold injury (NFCI) associated with cryotherapy.
Khoshnevis, Sepideh; Craik, Natalie K.; Matthew Brothers, R.; Diller, Kenneth R.
2016-01-01
The goal of this study was to investigate the persistence of cold-induced vasoconstriction following cessation of active skin-surface cooling. This study demonstrates a hysteresis effect that develops between skin temperature and blood perfusion during the cooling and subsequent rewarming period. An Arctic Ice cryotherapy unit (CTU) was applied to the knee region of six healthy subjects for 60 min of active cooling followed by 120 min of passive rewarming. Multiple laser Doppler flowmetry perfusion probes were used to measure skin blood flow (expressed as cutaneous vascular conductance (CVC)). Skin surface cooling produced a significant reduction in CVC (P < 0.001) that persisted throughout the duration of the rewarming period. In addition, there was a hysteresis effect between CVC and skin temperature during the cooling and subsequent rewarming cycle (P < 0.01). Mixed model regression (MMR) showed a significant difference in the slopes of the CVC–skin temperature curves during cooling and rewarming (P < 0.001). Piecewise regression was used to investigate the temperature thresholds for acceleration of CVC during the cooling and rewarming periods. The two thresholds were shown to be significantly different (P = 0.003). The results show that localized cooling causes significant vasoconstriction that continues beyond the active cooling period despite skin temperatures returning toward baseline values. The significant and persistent reduction in skin perfusion may contribute to nonfreezing cold injury (NFCI) associated with cryotherapy. PMID:26632263
Lee, Shong-Leih; Lu, Yung-Hsiang
2014-08-01
Heat transfer in a unit three-dimensional skin tissue with an embedded vascular system of actual histology structure is computed in the present work. The tissue temperature and the blood temperatures in artery and vein vessels are solved with a multi-grid system. The mean temperature of the tissue over the cross-section of the unit skin area is evaluated. The resulting one-dimensional function is regarded as the temperature of healthy tissue (or injured skin but the blood perfusion is still normally working) for large area of skin in view of the symmetric and periodic structure of the paired artery-vein vessels in nature. A three-dimensional bioheat equation then is formulated by the superposition of the skin burn wound effect and the healthy skin temperature with and without thermal radiation exposure. When this bioheat equation is employed to simulate ADT process on burn wounds, the decaying factor of the skin surface temperature is found to be a sharply decreasing function of time in the self-cooling stage after a thermal radiation heating. Nevertheless, the boundary of non-healing (needing surgery) and healing regions in a large burn wound can be estimated by tracking the peak of the gradient of decaying factor within 30 s after the thermal radiation is turned off. Experimental studies on the full ADT procedure are needed to justify the assumptions in the present computation. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.
STS-132 crew during their PDRS N-TSK MRM training in the building 16 cupola trainer.
2009-12-22
JSC2009-E-286971 (22 Dec. 2009) --- Astronauts Piers Sellers (left) and Garrett Reisman, both STS-132 mission specialists, participate in an exercise in the systems engineering simulator in the Avionics Systems Laboratory at NASA?s Johnson Space Center. The facility includes moving scenes of full-sized International Space Station components over a simulated Earth.
STS-132 crew during their PDRS N-TSK MRM training in the building 16 cupola trainer.
2009-12-22
JSC2009-E-286964 (22 Dec. 2009) --- Astronauts Ken Ham (foreground), STS-132 commander; and Mike Good, mission specialist, participate in an exercise in the systems engineering simulator in the Avionics Systems Laboratory at NASA?s Johnson Space Center. The facility includes moving scenes of full-sized International Space Station components over a simulated Earth.
STS-132 crew during their PDRS N-TSK MRM training in the building 16 cupola trainer.
2009-12-22
JSC2009-E-286961 (22 Dec. 2009) --- Astronaut Tony Antonelli, STS-132 pilot, uses a communication system during an exercise in the systems engineering simulator in the Avionics Systems Laboratory at NASA?s Johnson Space Center. The facility includes moving scenes of full-sized International Space Station components over a simulated Earth.
STS-132 crew during their PDRS N-TSK MRM training in the building 16 cupola trainer.
2009-12-22
JSC2009-E-286960 (22 Dec. 2009) --- Astronaut Tony Antonelli, STS-132 pilot, uses a communication system during an exercise in the systems engineering simulator in the Avionics Systems Laboratory at NASA?s Johnson Space Center. The facility includes moving scenes of full-sized International Space Station components over a simulated Earth.
Concentrating Solar Power Projects - La Africana | Concentrating Solar
: Posadas (Córdoba) Owner(s): Ortiz/TSK/Magtel (100%) Technology: Parabolic trough Turbine Capacity: Net -Field Outlet Temp: 393°C Solar-Field Temp Difference: 100°C Power Block Turbine Capacity (Gross): 50.0 MW Turbine Capacity (Net): 50.0 MW Output Type: Steam Rankine Cooling Method: Wet cooling Thermal
Key, Douglas J
2014-07-01
This study incorporates concurrent thermal camera imaging as a means of both safely extending the length of each treatment session within skin surface temperature tolerances and to demonstrate not only the homogeneous nature of skin surface temperature heating but the distribution of that heating pattern as a reflection of localization of subcutaneous fat distribution. Five subjects were selected because of a desire to reduce abdomen and flank fullness. Full treatment field thermal camera imaging was captured at 15 minute intervals, specifically at 15, 30, and 45 minutes into active treatment with the purpose of monitoring skin temperature and avoiding any patterns of skin temperature excess. Peak areas of heating corresponded anatomically to the patients' areas of greatest fat excess ie, visible "pinchable" fat. Preliminary observation of high-resolution thermal camera imaging used concurrently with focused field RF therapy show peak skin heating patterns overlying the areas of greatest fat excess.
Runeman, Bo; Rybo, Göran; Forsgren-Brusk, Ulla; Larkö, Olle; Larsson, Peter; Faergemann, Jan
2004-01-01
The aim of this study was to confirm findings that vapour-impermeable panty liners might impair skin climate, and to assess their impact on the skin microflora. Temperature, surface pH and aerobic microflora were measured on vulvar skin of 102 women. The mean skin temperature was 1.1 degrees C higher when using a vapour-impermeable panty liner compared with not using one. Use of panty liners with vapour-permeable back sheets and acidic cores resulted in skin temperature, pH and microflora levels that were very close to those observed in persons not using liners. The temperature, pH and total number of microorganisms were significantly lower for users of vapour-permeable panty liners than for users of vapour-impermeable ones (p <0.05, p<0.001 and p<0.001, respectively). The microorganism densities were usually higher when using the vapour-impermeable panty liner, but mean differences were minor. The use of panty liners seems not to imply a microbial risk for normal, healthy women.
Biometrical characteristics and physiological responses to a local cold exposure of the extremities.
Savourey, G; Sendowski, I; Bittel, J
1996-01-01
The aim of this study was firstly to describe the physiological responses observed in 19 subjects during immersion of the arm up to the elbow in water at 5 degrees C (5 min) followed by a 10-min recovery and secondly, to correlate the observed physiological responses with biometrical characteristics of the subjects (maximal oxygen uptake, VO2max, percentage fat content of whole body, BF, and arm, forearm and hand skinfold thickness). The results showed that the time courses of changes in forearm and hand skin temperature were different compared to those of finger skin temperatures both during local cooling and during rewarming (P < 0.05). Cardiovascular responses (heart rate, systolic and diastolic blood pressures) and finger skin temperatures were not related to the biometrical characteristics of the subjects. However, at the end of the immersion, decreased hand skin temperature was correlated to VO2max (r = 0.45, P < or = 0.05) whereas decreased forearm skin temperature was correlated both to VO2max (r = 0.44, P < or = 0.05) and to skinfold thickness (r = -0.44, P < or = 0.05) but not to BF. During the beginning of the recovery period only, outside, inside forearm and hand skin temperatures were related to VO2max (r = 0.54, P < or = 0.05; r = 0.66, P < or = 0.01 and r = 0.45, P < or = 0.05, respectively) and all the skinfold thicknesses (r = -0.47 to -0.71, P < or = 0.05). It was concluded that the local skin temperature profiles differed according to the upper limb segment both during cooling and during early rewarming. Moreover, VO2max and upper limb skinfold thickness but not BF did influence the forearm and hand skin temperature changes during cooling and early rewarming but not the finger skin temperature changes and cardiovascular responses.
Skin Temperature Rhythms in Humans Respond to Changes in the Timing of Sleep and Light.
Cuesta, Marc; Boudreau, Philippe; Cermakian, Nicolas; Boivin, Diane B
2017-06-01
Body temperature is known to vary with circadian phase and to be influenced by factors that can mask its circadian expression. We wanted to test whether skin temperature rhythms were sensitive to an abrupt shift of the sleep schedule and to the resetting effects of light. Nineteen healthy subjects spent 6 days in time isolation and underwent a simulated night-shift procedure. They were assigned to either a control group ( n = 10) or bright light group ( n = 9) and measurements were taken under a baseline day-oriented schedule and during the 4 th cycle of a night-oriented schedule. In the bright light group, participants were exposed to a 3-cycle 8-h exposure of ~6,500 lux at night, while the control group remained in dim light conditions (~3 lux). Skin temperature was recorded in 10 and 4 participants from the control and bright light groups, respectively. We found significant circadian rhythms of plasma melatonin, core body temperature (CBT), and skin temperature at baseline for both groups ( p < 0.001 for all). Rhythms of melatonin, CBT, and skin temperature following night shifts were significantly phase delayed by about 7 to 9 h ( p < 0.05) in response to bright light at night, whereas there was no shift in the control group. In addition, we found that at bedtime melatonin does not consistently increase before the increase in distal skin temperature and subsequent decrease in CBT, in contrast to what has been previously reported. The present study shows that, in constant posture conditions, skin temperature rhythms have an evoked component sensitive to abrupt changes in the timing of sleep. They also comprise an endogenous component that is sensitive to the resetting effects of bright light exposure. These results have applications for the determination of circadian phase, as skin temperature is less intrusive than rectal temperature recordings.
Observations and model predictions of water skin temperatures at MTI core site lakes and reservoirs
NASA Astrophysics Data System (ADS)
Garrett, Alfred J.; Kurzeja, Robert J.; O'Steen, Byron L.; Parker, Matthew J.; Pendergast, Malcolm M.; Villa-Aleman, Eliel; Pagnutti, Mary A.
2001-08-01
The Savannah River Technology Center (SRTC) measured water skin temperatures at four of the Multi-spectral Thermal Imager (MTI) core sites. The depression of the skin temperature relative to the bulk water temperature ((Delta) T) a few centimeters below the surface is a complex function of the weather conditions, turbulent mixing in the water and the bulk water temperature. Observed skin temperature depressions range from near zero to more than 1.0 degree(s)C. Skin temperature depressions tend to be larger when the bulk water temperature is high, but large depressions were also observed in cool bodies of water in calm conditions at night. We compared (Delta) T predictions from three models (SRTC, Schlussel and Wick) against measured (Delta) T's from 15 data sets taken at the MTI core sites. The SRTC and Wick models performed somewhat better than the Schlussel model, with RMSE and average absolute errors of about 0.2 degree(s)C, relative to 0.4 degree(s)C for the Schlussel model. The average observed (Delta) T for all 15 databases was -0.7 degree(s)C.
Skin temperature response to a liquid meal intake is different in men than in women.
Martinez-Tellez, Borja; Ortiz-Alvarez, Lourdes; Sanchez-Delgado, Guillermo; Xu, Huiwen; Acosta, Francisco M; Merchan-Ramirez, Elisa; Muñoz-Hernandez, Victoria; Martinez-Avila, Wendy D; Contreras-Gomez, Miguel A; Gil, Angel; Labayen, Idoia; Ruiz, Jonatan R
2018-06-02
The thermic effect of food (TEF) refers to the increase of the metabolic rate and body temperature in response to a single meal. To date, most of the studies have focused to determine the TEF in terms of energy expenditure, but little is known about which is the response in terms of skin temperature. The aim of this study was to analyze whether the thermic effect of food (TEF) on the skin temperature with a standardized and individualized liquid meal test is different in young adult men than in young adult women. A total of 104 young adults (36 men and 68 women, age: 18-25 years old) consumed a standardized and individualized liquid meal (energy intake: 50% of measured basal metabolic rate, 50% carbohydrates, 35% fat, 15% protein). The skin temperature was measured by means of 17 iButtons during 3 h and 20 min. The mean, proximal, distal, and supraclavicular skin temperature, as well as the peripheral gradient, were determined as a proxy of a peripheral vasoconstriction. The participants reported the thermal sensation of the whole body, clavicular, feet, and hands zones. The body composition was measured by dual X-ray absorptiometry. The overall, mean, proximal, and supraclavicular skin temperature significantly increased after the meal intake (all P < 0.05 vs. the baseline temperature). There was a postprandial peripheral vasoconstriction right after the meal intake and over the first hour and a peripheral vasodilatation during the second and third hour. Women had a higher increase in all skin temperature parameters in comparison to men (all, P < 0.05), whereas there were no sex differences in the proximal skin temperature (P = 0.279). The pattern of thermal sensation was similar between sexes, but women always felt colder than men. All of the results persisted after adjusting the analyses for body composition or menstrual cycle. A standardized and individualized liquid meal test increases the skin temperature in young adults, being the thermic effect higher in women than in men. Copyright © 2018 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Xu, Tianbai; Wang, Wenbo; Bian, Xiaolei; Wang, Xiaoxue; Wang, Xiaozhi; Luo, J K; Dong, Shurong
2015-08-13
Human skin contains multiple receptors, and is able to sense various stimuli such as temperature, pressure, force, corrosion etc, and to feel pains and the shape of objects. The development of skin-like sensors capable of sensing these stimuli is of great importance for various applications such as robots, touch detection, temperature monitoring, strain gauges etc. Great efforts have been made to develop high performance skin-like sensors, but they are far from perfect and much inferior to human skin as most of them can only sense one stimulus with focus on pressure (strain) or temperature, and are unable to visualize sensations and shape of objects. Here we report a skin-like sensor which imitates real skin with multiple receptors, and a new concept of pain sensation. The sensor with very high resolution not only has multiple sensations for touch, pressure, temperature, but also is able to sense various pains and reproduce the three dimensional shape of an object in contact.
Effects of wall temperature on skin-friction measurements by oil-film interferometry
NASA Astrophysics Data System (ADS)
Bottini, H.; Kurita, M.; Iijima, H.; Fukagata, K.
2015-10-01
Wind-tunnel skin-friction measurements with thin-oil-film interferometry have been taken on an aluminum sample to investigate the effects of wall temperature on the accuracy of the technique. The sample has been flush-mounted onto a flat plate with an electric heater at its bottom and mirror-smooth temperature-sensitive paint sprayed on its top. The heater has varied the sample temperature from ambient to 328 K, and the paint has permitted wall temperature measurements on the same area of the skin-friction measurements and during the same test. The measured wall temperatures have been used to calculate the correct oil viscosities, and these viscosities and the constant nominal viscosity at 298 K have been used to calculate two different sets of skin-friction coefficients. These sets have been compared to each other and with theoretical values. This comparison shows that the effects of wall temperature on the accuracy of skin-friction measurements are sensible, and more so as wall temperature differs from 298 K. Nonetheless, they are effectively neutralized by the use of wall temperature measurements in combination with the correct oil viscosity-temperature law. In this regard, the special temperature-sensitive paint developed for this study shows advantages with respect to more traditional wall temperature measurement techniques.
Changes of oxygen content in facial skin before and after cigarette smoking.
Fan, Guo-Biao; Wu, Pei-Lan; Wang, Xue-Min
2012-11-01
Cigarette smoking not only causes systemic health problems, but may also be an underlying cause of premature skin aging. Cigarette smokers frequently have morphological changes in facial skin that may be attributed to reduced oxygen in this region. The purpose of this study was to measure the oxygen content in facial skin before and after smoking. Twenty-five volunteers participated in this study. Changes in oxygen content of the facial skin were measured before and after 30 min of cigarette smoking. Skin temperature and oxygen content were evaluated in the periorbital and periolar regions. There was a significant increase in temperature after smoking. The oxy hemoglobin and partial pressure of oxygen decreased in both the periocular and perioral areas after smoking. There were no changes in deoxy hemoglobin and partial pressure of carbon dioxide at these areas. Significant changes were seen in temperature and oxygen content after only 30 min of smoking. The results from this study suggest that alterations in the skin temperature and oxygen content in facial skin after smoking may be an underlying cause of premature skin aging. © 2011 John Wiley & Sons A/S.
Prediction of human core body temperature using non-invasive measurement methods.
Niedermann, Reto; Wyss, Eva; Annaheim, Simon; Psikuta, Agnes; Davey, Sarah; Rossi, René Michel
2014-01-01
The measurement of core body temperature is an efficient method for monitoring heat stress amongst workers in hot conditions. However, invasive measurement of core body temperature (e.g. rectal, intestinal, oesophageal temperature) is impractical for such applications. Therefore, the aim of this study was to define relevant non-invasive measures to predict core body temperature under various conditions. We conducted two human subject studies with different experimental protocols, different environmental temperatures (10 °C, 30 °C) and different subjects. In both studies the same non-invasive measurement methods (skin temperature, skin heat flux, heart rate) were applied. A principle component analysis was conducted to extract independent factors, which were then used in a linear regression model. We identified six parameters (three skin temperatures, two skin heat fluxes and heart rate), which were included for the calculation of two factors. The predictive value of these factors for core body temperature was evaluated by a multiple regression analysis. The calculated root mean square deviation (rmsd) was in the range from 0.28 °C to 0.34 °C for all environmental conditions. These errors are similar to previous models using non-invasive measures to predict core body temperature. The results from this study illustrate that multiple physiological parameters (e.g. skin temperature and skin heat fluxes) are needed to predict core body temperature. In addition, the physiological measurements chosen in this study and the algorithm defined in this work are potentially applicable as real-time core body temperature monitoring to assess health risk in broad range of working conditions.
Biothermomechanics of skin tissues
NASA Astrophysics Data System (ADS)
Xu, F.; Lu, T. J.; Seffen, K. A.
Biothermomechanics of skin is highly interdisciplinary involving bioheat transfer, burn damage, biomechanics and neurophysiology. During heating, thermally induced mechanical stress arises due to the thermal denaturation of collagen, resulting in macroscale shrinkage. Thus, the strain, stress, temperature and thermal pain/damage are highly correlated; in other words, the problem is fully coupled. The aim of this study is to develop a computational approach to examine the heat transfer process and the heat-induced mechanical response, so that the differences among the clinically applied heating modalities can be quantified. Exact solutions for temperature, thermal damage and thermal stress for a single-layer skin model were first derived for different boundary conditions. For multilayer models, numerical simulations using the finite difference method (FDM) and finite element method (FEM) were used to analyze the temperature, burn damage and thermal stress distributions in the skin tissue. The results showed that the thermomechanical behavior of skin tissue is very complex: blood perfusion has little effect on thermal damage but large influence on skin temperature distribution, which, in turn, influences significantly the resulting thermal stress field; the stratum corneum layer, although very thin, has a large effect on the thermomechanical behavior of skin, suggesting that it should be properly accounted for in the modeling of skin thermal stresses; the stress caused by non-uniform temperature distribution in the skin may also contribute to the thermal pain sensation.
Effects of Cooling During Exercise on Thermoregulatory Responses of Men With Paraplegia.
Bongers, Coen C W G; Eijsvogels, Thijs M H; van Nes, Ilse J W; Hopman, Maria T E; Thijssen, Dick H J
2016-05-01
People with spinal cord injury (SCI) have an altered afferent input to the thermoregulatory center, resulting in a reduced efferent response (vasomotor control and sweating capacity) below the level of the lesion. Consequently, core body temperature rises more rapidly during exercise in individuals with SCI compared with people who are able-bodied. Cooling strategies may reduce the thermophysiological strain in SCI. The aim of this study was to examine the effects of a cooling vest on the core body temperature response of people with a thoracic SCI during submaximal exercise. Ten men (mean age=44 years, SD=11) with a thoracic lesion (T4-T5 or below) participated in this randomized crossover study. Participants performed two 45-minute exercise bouts at 50% maximal workload (ambient temperature 25°C), with participants randomized to a group wearing a cooling vest or a group wearing no vest (separate days). Core body temperature and skin temperature were continuously measured, and thermal sensation was assessed every 3 minutes. Exercise resulted in an increased core body temperature, skin temperature, and thermal sensation, whereas cooling did not affect core body temperature. The cooling vest effectively decreased skin temperature, increased the core-to-trunk skin temperature gradient, and tended to lower thermal sensation compared with the control condition. The lack of differences in core body temperature among conditions may be a result of the relative moderate ambient temperature in which the exercise was performed. Despite effectively lowering skin temperature and increasing the core-to-trunk skin temperature gradient, there was no impact of the cooling vest on the exercise-induced increase in core body temperature in men with low thoracic SCI. © 2016 American Physical Therapy Association.
Effects of whole body cryotherapy and cold water immersion on knee skin temperature.
Costello, J T; Donnelly, A E; Karki, A; Selfe, J
2014-01-01
This study sought to (a) compare and contrast the effect of 2 commonly used cryotherapy treatments, 4 min of -110 °C whole body cryotherapy and 8 °C cold water immersion, on knee skin temperature and (b) establish whether either protocol was capable of achieving a skin temperature (<13 °C) believed to be required for analgesic purposes. After ethics committee approval and written informed consent was obtained, 10 healthy males (26.5±4.9 yr, 183.5±6.0 cm, 90.7±19.9 kg, 26.8±5.0 kg/m2, 23.0±9.3% body fat; mean±SD) participated in this randomised controlled crossover study. Skin temperature around the patellar region was assessed in both knees via non-contact, infrared thermal imaging and recorded pre-, immediately post-treatment and every 10 min thereafter for 60 min. Compared to baseline, average, minimum and maximum skin temperatures were significantly reduced (p<0.001) immediately post-treatment and at 10, 20, 30, 40, 50 and 60 min after both cooling modalities. Average and minimum skin temperatures were lower (p<0.05) immediately after whole body cryotherapy (19.0±0.9 °C) compared to cold water immersion (20.5±0.6 °C). However, from 10 to 60 min post, the average, minimum and maximum skin temperatures were lower (p<0.05) following the cold water treatment. Finally, neither protocol achieved a skin temperature believed to be required to elicit an analgesic effect. © Georg Thieme Verlag KG Stuttgart · New York.
Biofeedback-assisted relaxation training to decrease test anxiety in nursing students.
Prato, Catherine A; Yucha, Carolyn B
2013-01-01
Nursing students experiencing debilitating test anxiety may be unable to demonstrate their knowledge and have potential for poor academic performance. A biofeedback-assisted relaxation training program was created to reduce test anxiety. Anxiety was measured using Spielberger's Test Anxiety Inventory and monitoring peripheral skin temperature, pulse, and respiration rates during the training. Participants were introduced to diaphragmatic breathing, progressive muscle relaxation, and autogenic training. Statistically significant changes occurred in respiratory rates and skin temperatures during the diaphragmatic breathing session; respiratory rates and peripheral skin temperatures during progressive muscle relaxation session; respiratory and pulse rates, and peripheral skin temperatures during the autogenic sessions. No statistically significant difference was noted between the first and second TAI. Subjective test anxiety scores of the students did not decrease by the end of training. Autogenic training session was most effective in showing a statistically significant change in decreased respiratory and pulse rates and increased peripheral skin temperature.
Jones, Helen; Eijsvogels, Thijs M H; Nyakayiru, Jean; Verheggen, Rebecca J H M; Thompson, Andrew; Groothuis, Jan T; Atkinson, Greg; Hopman, Maria T E; Thijssen, Dick H J
2014-03-01
Individuals with a spinal cord injury (SCI) demonstrate altered circadian variation in thermoregulatory control. Recently, we reported that tetraplegia is associated with a blunted release of melatonin in the evening. In order to examine whether this finding relates to circadian thermoregulation, we compared the correlations between evening changes in melatonin, core and skin temperature between thoracic and cervical SCI and able-bodied participants. In 10 able-bodied, 9 paraplegic and 8 tetraplegic participants, we measured, between 1900 and 2300 h, core temperature, proximal skin temperature (above and below the level of the lesion) and physical activity. Salivary melatonin was also sampled during this period and analyzed using enzyme linked immunosorbant assay. Between 1900 and 2300 h, core and upper limb skin temperature gradually decreased in all groups (p = 0.01). A significant group × time interaction was evident in lower body skin temperature (p = 0.03). Lower body skin temperature was significantly higher in able-bodied controls compared with tetraplegics between 1900 and 2000 h (p < 0.05). In able-bodied and paraplegic participants, the changes in melatonin and core temperature were inversely correlated (r = -0.44 and -0.54, respectively, both p = 0.01). Melatonin and mean skin temperature changes were also inversely correlated (able-bodied controls: r = -0.24; p = 0.05 and paraplegics: r = -0.30; p= 0.02). The inverse correlation between evening changes in melatonin and thermoregulation is of a similar magnitude in paraplegic and able-bodied controls. In contrast, changes in skin temperature, below the level of the lesion, are unrelated to changes in melatonin in tetraplegics.
Romeijn, Nico; Verweij, Ilse M; Koeleman, Anne; Mooij, Anne; Steimke, Rosa; Virkkala, Jussi; van der Werf, Ysbrand; Van Someren, Eus J W
2012-12-01
Vigilance is affected by induced and spontaneous skin temperature fluctuations. Whereas sleep deprivation strongly affects vigilance, no previous study examined in detail its effect on human skin temperature fluctuations and their association with vigilance. In a repeated-measures constant routine design, skin temperatures were assessed continuously from 14 locations while performance was assessed using a reaction time task, including eyes-open video monitoring, performed five times a day for 2 days, after a normal sleep or sleep deprivation night. Participants were seated in a dimly lit, temperature-controlled laboratory. Eight healthy young adults (five males, age 22.0 ± 1.8 yr (mean ± standard deviation)). One night of sleep deprivation. Mixed-effect regression models were used to evaluate the effect of sleep deprivation on skin temperature gradients of the upper (ear-mastoid), middle (hand-arm), and lower (foot-leg) body, and on the association between fluctuations in performance and in temperature gradients. Sleep deprivation induced a marked dissociation of thermoregulatory skin temperature gradients, indicative of attenuated heat loss from the hands co-occurring with enhanced heat loss from the feet. Sleep deprivation moreover attenuated the association between fluctuations in performance and temperature gradients; the association was best preserved for the upper body gradient. Sleep deprivation disrupts coordination of fluctuations in thermoregulatory skin temperature gradients. The dissociation of middle and lower body temperature gradients may therefore be evaluated as a marker for sleep debt, and the upper body gradient as a possible aid in vigilance assessment when sleep debt is unknown. Importantly, our findings suggest that sleep deprivation affects the coordination between skin blood flow fluctuations and the baroreceptor-mediated cardiovascular regulation that prevents venous pooling of blood in the lower limbs when there is the orthostatic challenge of an upright posture.
Supraclavicular Skin Temperature as a Measure of 18F-FDG Uptake by BAT in Human Subjects
van der Linden, Rianne A. D.; Pereira Arias-Bouda, Lenka; Smit, Frits; Verberne, Hein J.; van Marken Lichtenbelt, Wouter D.
2014-01-01
Background Brown adipose tissue (BAT) has emerged as a novel player in energy homeostasis in humans and is considered a potential new target for combating obesity and related diseases. The current ‘gold standard’ for quantification of BAT volume and activity is cold-induced 18F-FDG uptake in BAT. However, use of this technique is limited by cost and radiation exposure. Given the fact that BAT is a thermogenic tissue, mainly located in the supraclavicular region, the aim of the current study was to investigate whether cold-induced supraclavicular skin temperature and core body temperature may be alternative markers of BAT activation in humans. Subjects/Methods BAT volume and activity were measured in 24 healthy lean adolescent males (mean age 24.1±0.8 years), using cold-induced 18F-FDG uptake with PET-CT. Core body temperature was measured continuously in the small intestine with use of an ingestible telemetric capsule and skin temperature was measured by eighteen wireless iButtons attached to the skin following ISO-defined locations. Results Proximal and distal (hand/feet) skin temperatures markedly decreased upon cold exposure, while supraclavicular skin temperature significantly increased (35.2±0.1 vs. 35.5±0.1°C, p = 0.001). Furthermore, cold-induced supraclavicular skin temperature positively correlated with both total (R2 = 0.28, P = 0.010) and clavicular BAT volume (R2 = 0.20, P = 0.030) and clavicular SUVmax (R2 = 0.27, P = 0.010), while core body temperature did not. Conclusions Supraclavicular skin temperature as measured by iButtons may have predictive value for BAT detection in adult humans. This is highly desirable considering the increasing interest in pharmacological interventions to stimulate BAT in human subjects. Trial Registration NTR 2473 PMID:24922545
Boron/aluminum skins for the DC-10 aft pylon
NASA Technical Reports Server (NTRS)
Elliott, S. Y.
1975-01-01
Boron/aluminum pylon boat tail skins were designed and fabricated and installed on the DC-10 aircraft for a 5-year flight service demonstration test. Inspection and tests of the exposed skins will establish the ability of the boron/aluminum composite to withstand long time flight service conditions, which include exposure to high temperatures, sonic fatigue, and flutter. The results of a preliminary testing program yield room temperature and elevated temperature data on the tension, compression, in-plane shear, interlaminar shear, bolt bearing, and tension fatigue properties of the boron/aluminum laminates. Present technology was used in the fabrication of the skins. Although maximum weight saving was not sought, weight of the constant thickness boron/aluminum skin is 26% less than the chemically milled titanium skin.
Mendt, Stefan; Maggioni, Martina Anna; Nordine, Michael; Steinach, Mathias; Opatz, Oliver; Belavý, Daniel; Felsenberg, Dieter; Koch, Jochim; Shang, Peng; Gunga, Hanns-Christian; Stahn, Alexander
2017-01-01
Continuous recordings of core body temperature (CBT) are a well-established approach in describing circadian rhythms. Given the discomfort of invasive CBT measurement techniques, the use of skin temperature recordings has been proposed as a surrogate. More recently, we proposed a heat-flux approach (the so-called Double Sensor) for monitoring CBT. Studies investigating the reliability of the heat-flux approach over a 24-hour period, as well as comparisons with skin temperature recordings, are however lacking. The first aim of the study was therefore to compare rectal, skin, and heat-flux temperature recordings for monitoring circadian rhythm. In addition, to assess the optimal placement of sensor probes, we also investigated the effect of different anatomical measurement sites, i.e. sensor probes positioned at the forehead vs. the sternum. Data were collected as part of the Berlin BedRest study (BBR2-2) under controlled, standardized, and thermoneutral conditions. 24-hours temperature data of seven healthy males were collected after 50 days of -6° head-down tilt bed-rest. Mean Pearson correlation coefficients indicated a high association between rectal and forehead temperature recordings (r > 0.80 for skin and Double Sensor). In contrast, only a poor to moderate relationship was observed for sensors positioned at the sternum (r = -0.02 and r = 0.52 for skin and Double Sensor, respectively). Cross-correlation analyses further confirmed the feasibility of the forehead as a preferred monitoring site. The phase difference between forehead Double Sensor and rectal recordings was not statistically different from zero (p = 0.313), and was significantly smaller than the phase difference between forehead skin and rectal temperatures (p = 0.016). These findings were substantiated by cosinor analyses, revealing significant differences for mesor, amplitude, and acrophase between rectal and forehead skin temperature recordings, but not between forehead Double Sensor and rectal temperature measurements. Finally, Bland-Altman analysis indicated narrower limits of agreement for rhythm parameters between rectal and Double Sensor measurements compared to between rectal and skin recordings, irrespective of the measurement site (i.e. forehead, sternum). Based on these data we conclude that (1) Double Sensor recordings are significantly superior to skin temperature measurements for non-invasively assessing the circadian rhythm of rectal temperature, and (2) temperature rhythms from the sternum are less reliable than from the forehead. We suggest that forehead Double Sensor recordings may provide a surrogate for rectal temperature in circadian rhythm research, where constant routine protocols are applied. Future studies will be needed to assess the sensor's ecological validity outside the laboratory under changing environmental and physiological conditions.
Skin temperature, thermal comfort, sweating, clothing and activity of men sledging in Antarctica
Budd, G. M.
1966-01-01
1. Three men were studied while dog-sledging 320 km in 12 days in Antarctica. Conventional Antarctic clothing (`sweaters and windproofs') was worn. Four hundred observations were made of medial thigh skin temperature, thermal comfort, sweating, clothing, activity and environmental conditions. 2. Work occupied an average of 11·0 hr/day and sleep 7·5 hr. Estimated daily energy expenditure averaged 5100 kcal (range 2740-6660 kcal). 3. Skin temperature fell on exposure to cold despite the clothing worn, but was not changed by the level of activity. Sweating, and thermal comfort, were directly related to both skin temperature and activity. 4. Inside the tent, the modal value of skin temperature was 33° C (range 27-36° C) and the men were comfortable in 94% of observations. 5. During the 9·2 hr/day spent outdoors the modal value of skin temperature was 27° C (range 18-33° C) and the men felt too cold (but did not shiver) in 11% (range 7-20%) of observations, suggesting that cold stress was not negligible. However, they also felt too hot in 20% of observations and were sweating in 23%. PMID:5914254
Nam, G W; Baek, J H; Koh, J S; Hwang, J-K
2015-02-01
Age, gender, regional, and ethnic differences influence skin conditions. The purpose of this study was to observe the effects of environments, especially the air temperature, relative humidity, air pressure, duration of sunshine, and precipitation on skin, and the seasonal variation in skin hydration, sebum, scales, brightness, and elasticity in Korean females. The study included 89 Korean subjects, aged 29.7 ± 6.2 years. The five skin biophysical parameters (skin hydration, sebum, scales, brightness, and elasticity) were measured at six sites: forehead, under the eye, frontal cheek, crow's foot, lateral cheek, and inner forearm. Skin hydration was measured using the Corneometer® CM 825. Skin sebum was measured with Sebumeter® SM 815. Skin scaliness was measured with Visioscan® VC 98. Skin brightness (L* value) was measured by using Spectrophotometer. A suction chamber device, Cutometer® MPA 580, was used to measure the skin elasticity. The measurements were performed every month for 13 months, from April 2007 to April 2008. There were significantly seasonal variations in environmental factors. The air temperature was the lowest in January (-1.7°C), and the highest in August (26.5°C). The relative humidity was the lowest in February (46%), and the highest in July and August (75%). There was a negative correlation between skin scaliness and three environmental factors such as air temperature, relative humidity, and highest precipitation. There was a positive correlation between skin scaliness and two environmental factors such as air pressure and duration of sunshine. Elasticity was correlated with air temperature positively and with air pressure negatively. The correlations shown between the skin biophysical parameters and environmental factors demonstrate that the skin biophysical parameters are affected by environmental factors. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
NASA Technical Reports Server (NTRS)
Radakovich, Jon; Bosilovich, M.; Chern, Jiun-dar; daSilva, Arlindo
2004-01-01
The NASA/NCAR Finite Volume GCM (fvGCM) with the NCAR CLM (Community Land Model) version 2.0 was integrated into the NASA/GMAO Finite Volume Data Assimilation System (fvDAS). A new method was developed for coupled skin temperature assimilation and bias correction where the analysis increment and bias correction term is passed into the CLM2 and considered a forcing term in the solution to the energy balance. For our purposes, the fvDAS CLM2 was run at 1 deg. x 1.25 deg. horizontal resolution with 55 vertical levels. We assimilate the ISCCP-DX (30 km resolution) surface temperature product. The atmospheric analysis was performed 6-hourly, while the skin temperature analysis was performed 3-hourly. The bias correction term, which was updated at the analysis times, was added to the skin temperature tendency equation at every timestep. In this presentation, we focus on the validation of the surface energy budget at the in situ reference sites for the Coordinated Enhanced Observation Period (CEOP). We will concentrate on sites that include independent skin temperature measurements and complete energy budget observations for the month of July 2001. In addition, MODIS skin temperature will be used for validation. Several assimilations were conducted and preliminary results will be presented.
Kräuchi, Kurt; Konieczka, Katarzyna; Roescheisen-Weich, Corina; Gompper, Britta; Hauenstein, Daniela; Schoetzau, Andreas; Fraenkl, Stephan; Flammer, Josef
2014-02-01
Diurnal cycle variations in body-heat loss and heat production, and their resulting core body temperature (CBT), are relatively well investigated; however, little is known about their variations across the menstrual cycle under ambulatory conditions. The main purpose of this study was to determine whether menstrual cycle variations in distal and proximal skin temperatures exhibit similar patterns to those of diurnal variations, with lower internal heat conductance when CBT is high, i.e. during the luteal phase. Furthermore, we tested these relationships in two groups of women, with and without thermal discomfort of cold extremities (TDCE). In total, 19 healthy eumenorrheic women with regular menstrual cycles (28-32 days), 9 with habitual TDCE (ages 29 ± 1.5 year; BMI 20.1 ± 0.4) and 10 controls without these symptoms (CON: aged 27 ± 0.8 year; BMI 22.7 ± 0.6; p < 0.004 different to TDCE) took part in the study. Twenty-eight days continuous ambulatory skin temperature measurements of distal (mean of hands and feet) and proximal (mean of sternum and infraclavicular regions) skin regions, thighs, and calves were carried out under real-life, ambulatory conditions (i-Buttons® skin probes, sampling rate: 2.5 min). The distal minus proximal skin temperature gradient (DPG) provided a valuable measure for heat redistribution from the core to the shell, and, hence, for internal heat conduction. Additionally, basal body temperature was measured sublingually directly after waking up in bed. Mean diurnal amplitudes in skin temperatures increased from proximal to distal skin regions and the 24-h mean values were inversely related. TDCE compared to CON showed significantly lower hand skin temperatures and DPG during daytime. However, menstrual cycle phase did not modify these diurnal patterns, indicating that menstrual and diurnal cycle variations in skin temperatures reveal additive effects. Most striking was the finding that all measured skin temperatures, together with basal body temperature, revealed a similar menstrual cycle variation (independent of BMI), with highest and lowest values during the luteal and follicular phases, respectively. These findings lead to the conclusion that in contrast to diurnal cycle, variations in CBT variation across the menstrual cycle cannot be explained by changes in internal heat conduction under ambulatory conditions. Although no measurements of metabolic heat production were carried out increased metabolic heat generation during the luteal phase seems to be the most plausible explanation for similar body temperature increases.
NASA Astrophysics Data System (ADS)
Zhang, Wencan; Chen, Jiqing; Lan, Fengchong
2014-03-01
The existing investigations on thermal comfort mostly focus on the thermal environment conditions, especially of the air-flow field and the temperature distributions in vehicle cabin. Less attention appears to direct to the thermal comfort or thermal sensation of occupants, even to the relationship between thermal conditions and thermal sensation. In this paper, a series of experiments were designed and conducted for understanding the non-uniform conditions and the occupant's thermal responses in vehicle cabin during the heating period. To accurately assess the transient temperature distribution in cabin in common daily condition, the air temperature at a number of positions is measured in a full size vehicle cabin under natural winter environment in South China by using a discrete thermocouples network. The occupant body is divided into nine segments, the skin temperature at each segment and the occupant's local thermal sensation at the head, body, upper limb and lower limb are monitored continuously. The skin temperature is observed by using a discrete thermocouples network, and the local thermal sensation is evaluated by using a seven-point thermal comfort survey questionnaire proposed by American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc(ASHRAE) Standard. The relationship between the skin temperature and the thermal sensation is discussed and regressed by statistics method. The results show that the interior air temperature is highly non-uniform over the vehicle cabin. The locations where the occupants sit have a significant effect on the occupant's thermal responses, including the skin temperature and the thermal sensation. The skin temperature and thermal sensation are quite different between body segments due to the effect of non-uniform conditions, clothing resistance, and the human thermal regulating system. A quantitative relationship between the thermal sensation and the skin temperature at each body segment of occupant in real life traffic is presented. The investigation result indicates that the skin temperature is a robust index to evaluate the thermal sensation. Applying the skin temperature to designing and controlling parameters of the heating, ventilation and air conditioning(HVAC) system may benefit the thermal comfort and reducing energy consumption.
STS-132 crew during their PDRS N-TSK MRM training in the building 16 cupola trainer.
2009-12-22
JSC2009-E-286973 (22 Dec. 2009) --- Astronauts Ken Ham (left), STS-132 commander; Tony Antonelli (center), pilot; and Mike Good, mission specialist, participate in an exercise in the systems engineering simulator in the Avionics Systems Laboratory at NASA?s Johnson Space Center. The facility includes moving scenes of full-sized International Space Station components over a simulated Earth.
STS-132 crew during their PDRS N-TSK MRM training in the building 16 cupola trainer.
2009-12-22
JSC2009-E-286968 (22 Dec. 2009) --- Astronauts Ken Ham (left), STS-132 commander; Tony Antonelli (right), pilot; and Mike Good, mission specialist, participate in an exercise in the systems engineering simulator in the Avionics Systems Laboratory at NASA?s Johnson Space Center. The facility includes moving scenes of full-sized International Space Station components over a simulated Earth.
Feigenbaum, Luis A; Baraga, Michael; Kaplan, Lee D; Roach, Kathryn E; Calpino, Kathryn M; Dorsey, Katie; Martorelli, Cristina; Sagarduy, Beatriz; King, Lesley-Anne; Scavo, Vincent A
2015-02-01
Much attention has been solely paid to physical outcome measures for return to sport after injury in the past. However, current research shows that the psychological component of these injuries can be more predictive of return to sport than physical outcome measures. The purpose of this case report is to describe the successful return to sport following surgery of a complicated tibia and fibula fracture of a Division I collegiate women's soccer player with a low level of kinesiophobia. A 22-year-old female sustained a closed traumatic mid-shaft fracture of her tibia and fibula. During a high velocity play she sustained a direct blow while colliding with an opposing player's cleats. As a result of the play, her distal tibia was displaced 908 to the rest of her leg. She underwent a closed reduction and tibial internal fixation with an intramedullary rod. Outcome scores were tracked using the IKDC and TSK-11. The IKDC measures symptoms, function, and sport activity related to knee injuries. The TSK-11 measures fear of movement and re-injury, which was important to assess during this case due to the gruesome nature of the injury. At 4 months, the subject became symptomatic over the fibula and was diagnosed with a fibular nonunion fracture. This was unexpected due to the low incidence of and usual asymptomatic nature of fibular nonunion fractures, which required an additional surgery. TSK-11 scores ranged from 19-20 throughout, signifying low levels of kinesiophobia. IKDC scores improved from 8.05 to 60.92. The subject ultimately signed a professional soccer contract. The rehabilitation of this subject was complex due to her low levels of kinesiophobia, self-guided overtraining, and the potential role they may have had in her fibular nonunion fracture. This case study demonstrates a successful outcome despite a unique injury presentation, multiple surgeries, and low levels of kinesiophobia. While a low level of kinesiophobia can be detrimental to rehabilitation compliance, it may have benefited her in the long-term. 5.
Hasselberg, Michael J; McMahon, James; Parker, Kathy
2013-01-01
Changes in core body temperature due to heat transfer through the skin have a major influence on sleep regulation. Traditional measures of skin temperature are often complicated by extensive wiring and are not practical for use in normal living conditions. This review describes studies examining the reliability, validity and utility of the iButton®, a wireless peripheral thermometry device, in sleep/wake research. A review was conducted of English language literature on the iButton as a measure of circadian body temperature rhythms associated with the sleep/wake cycle. Seven studies of the iButtton as a measure of human body temperature were included. The iButton was found to be a reliable and valid measure of body temperature. Its application to human skin was shown to be comfortable and tolerable with no significant adverse reactions. Distal skin temperatures were negatively correlated with sleep/wake activity, and the temperature gradient between the distal and proximal skin (DPG) was identified as an accurate physiological correlate of sleep propensity. Methodological issues included site of data logger placement, temperature masking factors, and temperature data analysis. The iButton is an inexpensive, wireless data logger that can be used to obtain a valid measurement of human skin temperature. It is a practical alternative to traditional measures of circadian rhythms in sleep/wake research. Further research is needed to determine the utility of the iButton in vulnerable populations, including those with neurodegenerative disorders and memory impairment and pediatric populations. Copyright © 2011 Elsevier B.V. All rights reserved.
Cox, Jill; Kaes, Loretta; Martinez, Miguel; Moles, Daniel
2016-10-01
Skin temperature may help prospectively determine whether an area of skin discoloration will evolve into necrosis. A prospective, observational study was conducted in 7 skilled nursing facilities to determine if skin temperature measured using infrared thermography could predict the progression of discolored intact skin (blanchable erythema, Stage 1 pressure ulcer, or sus- pected deep tissue injury [sDTI]) to necrosis and to evaluate if nurses could effectively integrate thermography into the clinical setting. Patients residing in or presenting to the facility between October 2014 and August 2015 with a pressure-related area of discolored skin determined to be blanchable erythema, a Stage 1 pressure ulcer, or sDTI and anticipated length of stay >6 days were assessed at initial presentation of the discolored area and after 7 and 14 days by facility nurses trained on camera operation and study protocol. Variables included patient demographic and clinical data, data related to the discolored area (eg, size, date of initial discovery), and temperature and appearance differences between discolored and adjacent intact skin. Skin temperatures at the discolored and adjacent areas were measured during the initial assessment. All facility pressure ulcer prevention and treatment protocols derived from evidence-based clinical practice guidelines remained in use during the study time period. Participating nurses completed a 2-part, pencil/paper survey to examine the feasibility of incorporating thermography for skin assessment into practice. Data analyses were performed using descriptive statistics (frequency analyses) and bivariate analysis (t-tests and chi-squared tests); logistic regression was used to assess associations among patient and pressure ulcer variables. Of the 67 patients studied, the overall mean age was 85 years (SD 10); 52 were women; 63 were Caucasian; and the top 3 diagnoses, accounting for 60% of the study sample, included neurologic (ie, cardiovascular acci- dent/dementia [14, 21%]), cardiac-related (14, 21%), and orthopedic (13, 19%) conditions. Twenty-eight (28) participants were long-term care patients, and 39 were admitted as short-stay patients. The most frequently reported location of discolored intact skin on presentation was the heel (27, 40%). The mean temperature at the site of the discolored skin was 33.6 ̊ C (SD 3) and at the adjacent skin was 33.5 ̊ C (SD 2.5). The mean size of the areas of discoloration was 11 cm2 (SD 21). Capillary refill of the discolored area was absent on initial presentation in 49 patients (72%), and demarcation of the discolored borders was evident for 45 (66%). Of the 67 patients, 30 (45%) experienced complete resolution of the discolored area. At day 7, 8 (16%) of the remaining 50 patients in the sample exhibited skin necrosis and at day 14, a total of 12 patients of the remaining 37 (32%) exhibited skin necrosis. At day 7, skin necrosis was significantly associated with admission to a subacute unit (P = 0.01) and at day 14 to negative capillary refill at initial presentation (P = 0.02). Regardless of skin temperature, negative capillary refill at presentation was significantly associated with skin necrosis at day 7 (P = 0.04). A dichotomous variable was constructed to examine patients with cooler temperatures at the site as compared to their adjacent skin and persons with warmer skin temperatures at the center of the discolored skin for the presence of skin necrosis at both day 7 and day 14. In multivariate analysis, patients with cooler rather than warmer skin temperatures at the center of the discolored area as compared to the adjacent skin were more likely to develop necrosis by day 7 (OR 18.8; P = 0.05; CI: 104-342.44). Participating nurses were uncertain about the feasibility of integrating thermography into practice. Larger prospective studies with more heterogeneous samples are needed to determine the validity of skin temperature measurement as a predictor of skin necrosis and the utility of implementing thermography into clinical practice.
Hot or not? Thermal reactions to social contact.
Hahn, Amanda C; Whitehead, Ross D; Albrecht, Marion; Lefevre, Carmen E; Perrett, David I
2012-10-23
Previous studies using thermal imaging have suggested that face and body temperature increase during periods of sexual arousal. Additionally, facial skin temperature changes are associated with other forms of emotional arousal, including fear and stress. This study investigated whether interpersonal social contact can elicit facial temperature changes. Study 1: infrared images were taken during a standardized interaction with a same- and opposite-sex experimenter using skin contact in a number of potentially high-intimate (face and chest) and low-intimate (arm and palm) locations. Facial skin temperatures significantly increased from baseline during the face and chest contact, and these temperature shifts were larger when contact was made by an opposite-sex experimenter. Study 2: the topography of facial temperature change was investigated in five regions: forehead, periorbital, nose, mouth and cheeks. Increased temperature in the periorbital, nose and mouth regions predicted overall facial temperature shifts to social contact. Our findings demonstrate skin temperature changes are a sensitive index of arousal during interpersonal interactions.
Characteristics of wettedness and equi-skin temperature line in the evaporative regulation region
NASA Astrophysics Data System (ADS)
Mochida, T.
1983-07-01
As a result of the analysis of physiological experimental data, the characteristics of the wettedness were clarified, i.e., the value of the wettedness is not constant but differs in accordance with the environmental humidity even when the skin temperature is the same, and it was shown that the evaporative heat loss from the skin surface is inversely proportional to the wetttedness. Based on the properties of the wetedness observed, a new thermal sensation chart in the evaporative regulation region was proposed as an index for evaluating the warmth or the coldness in the environment. The feature of the present chart is that the locus of the equal skin temperature appears as a curved line on the psychrometric chart and that the wettedness on the equi-skin temperature line is not constant but takes varying values. The curved equal skin temperature line means that the influence of the environmental humidity on thermal sensation becomes smaller as the humidity of the environmental humidity on thermal sensation becomes smaller as the humidity of the environment is lowered.
Mechanisms of Drying of Skin Forming Materials
NASA Astrophysics Data System (ADS)
Hassan, Haydar Mahmood
Available from UMI in association with The British Library. The literature relating to evaporation from single droplets of pure liquids, and to the drying of droplets containing solids and of droplet sprays has been reviewed. The heat and mass transfer rates for a single droplet suspended from a nozzle were studied within a 42mm I.D. horizontal wind tunnel designed to supply hot dry air, to simulate conditions encountered in practical spray dryer. A novel rotating glass nozzle was developed to facilitate direct measurements of droplet weight and core temperature. This design minimised heat conduction through the nozzle. Revised correlations were obtained for heat and mass transfer coefficients, for evaporation from pure water droplets suspended from a rotating nozzle. (UNFORMATTED TABLE OR EQUATION FOLLOWS)eqalign {rm Nu&= rm 2.0 + 0.27 ({1over B})^{0.18}Re^{0.5}Pr ^{0.33}crrm Sh&= rm 2.0 + 0.575({Ta-Ts over Tamb})^{ -0.04}Re^{0.5}Sc^{0.33 }cr}(TABLE/EQUATION ENDS)Experimental drying studies were carried out on single droplets of different types of skin-forming materials, namely, custard, starch, gelatin, skim milk and fructose at air temperatures ranging from 19^circC to 198 ^circC. Dried crusts were recovered and examined by Scanning Electron Microscopy. Skin-forming materials were classified into three types according to the mechanisms of skin formation. In the first type (typified by droplets of custard and starch) skin formed due to gelatinisation at high temperatures. Increasing the drying temperature resulted in increased crust resistance to mass transfer due to increased granule swelling and the crust resistance was completely transferred to a skin resistance at drying temperatures >150 ^circC. In the second type e.g. gelatin droplets the skin formed immediately drying had taken place at any drying temperature. At drying temperature >60^circC a more resistant skin was formed. In the third type (typified by droplets of skim milk and fructose) the skin appeared on the droplet at a certain stage of the drying process under any drying conditions. As the drying temperature was increased the resistance of the skin to mass transfer increased. The drying rate history of any material depended upon the nature of the skin formed which, in turn, depended upon the drying conditions. A mathematical model was proposed for the drying of the first type of skin-forming material. This was based on the assumption that, once all the granules gelatinised at the gelatinisation temperature, a skin appeared instantaneously on the droplet surface. The experimentally-observed times at which the skin appeared on the droplets surfaces were in excellent agreement with those predicted from the model. The work should assist in understanding the fundamentals of particulate drying processes, particularly when skin -formation occurs and may be a crucial factor in volatiles retention.
Diurnal and nocturnal skin temperature regulation in chronic complex regional pain syndrome.
Schilder, Johanna C M; Niehof, Sjoerd P; Marinus, Johan; van Hilten, Jacobus J
2015-03-01
Skin temperature changes due to vasomotor disturbances are important features of complex regional pain syndrome (CRPS). Because this phenomenon has only been studied under controlled conditions, information on daily circadian variability is lacking. Also, studies in chronic CRPS patients with abnormal posturing, in which coldness of the affected extremity is more common, do not exist. We examined the response to external heating as well as circadian temperature changes over several days in the affected legs of 14 chronic CRPS patients with abnormal posturing and 17 controls. Skin temperatures were recorded hourly for 14 days using wireless sensors. Although the patients' affected extremities were significantly colder before external heating, the vasodilatory response was similar in the 2 groups. Additionally, median skin temperature differences between both legs and their variability was larger in patients than in controls during the day, but not during the night. These findings indicate that the mechanisms underlying impaired skin circulation in CRPS during daytime are reversible under certain circumstances. The large variation in skin temperature differences during the day questions the validity of using a single measurement in the diagnosis of CRPS, and our results indicate that only temperature differences >1.0 °C should be considered to reflect vasomotor disturbances. This article shows that chronic CRPS patients have a normal vasodilatory response to external heating and that skin temperature differences between the affected and unaffected lower limbs, which were highly variable during daytime, disappeared during sleep. This indicates that part of the vasomotor regulation in these patients is still functional. Copyright © 2015 American Pain Society. Published by Elsevier Inc. All rights reserved.
Ho, Hung Chak; Knudby, Anders; Xu, Yongming; Hodul, Matus; Aminipouri, Mehdi
2016-02-15
Apparent temperature is more closely related to mortality during extreme heat events than other temperature variables, yet spatial epidemiology studies typically use skin temperature (also known as land surface temperature) to quantify heat exposure because it is relatively easy to map from satellite data. An empirical approach to map apparent temperature at the neighborhood scale, which relies on publicly available weather station observations and spatial data layers combined in a random forest regression model, was demonstrated for greater Vancouver, Canada. Model errors were acceptable (cross-validated RMSE=2.04 °C) and the resulting map of apparent temperature, calibrated for a typical hot summer day, corresponded well with past temperature research in the area. A comparison with field measurements as well as similar maps of skin temperature and air temperature revealed that skin temperature was poorly correlated with both air temperature (R(2)=0.38) and apparent temperature (R(2)=0.39). While the latter two were more similar (R(2)=0.87), apparent temperature was predicted to exceed air temperature by more than 5 °C in several urban areas as well as around the confluence of the Pitt and Fraser rivers. We conclude that skin temperature is not a suitable proxy for human heat exposure, and that spatial epidemiology studies could benefit from mapping apparent temperature, using an approach similar to the one reported here, to better quantify differences in heat exposure that exist across an urban landscape. Copyright © 2015 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Biswal, N C; Wu, Z; Chu, J
Purpose: To assess the potential of dynamic infrared imaging to evaluate early skin reactions during radiation therapy in cancer patients. Methods: Thermal images were captured by our home-built system consisting of two flash lamps and an infrared (IR) camera. The surface temperature of the skin was first raised by ∼ 6 °C from ∼1 ms short flashes; the camera then captured a series of IR images for 10 seconds. For each image series, a basal temperature was recorded for 0.5 seconds before flash was triggered. The temperature gradients (ε) were calculated between a reference point (immediately after the flash) andmore » at a time point of 2sec, 4sec and 9sec after that. A 1.0 cm region of interest (ROI) on the skin was drawn; the mean and standard deviations of the ROIs were calculated. The standard ε values for normal human skins were evaluated by imaging 3 healthy subjects with different skin colors. All of them were imaged on 3 separate days for consistency checks. Results: The temperature gradient, which is the temperature recovery rate, depends on the thermal properties of underlying tissue, i.e. thermal conductivity. The average ε for three volunteers averaged over 3 measurements were 0.64±0.1, 0.72±0.2 and 0.80±0.3 at 2sec, 4sec and 9sec respectively. The standard deviations were within 1.5%–3.2%. One of the volunteers had a prior small skin burn on the left wrist and the ε values for the burned site were around 9% (at 4sec) and 13% (at 9sec) lower than that from the nearby normal skin. Conclusion: The temperature gradients from the healthy subjects were reproducible within 1.5%–3.2 % and that from a burned skin showed a significant difference (9%–13%) from the normal skin. We have an IRB approved protocol to image head and neck patients scheduled for radiation therapy.« less
Su, Ya; Yao, X. Steve; Li, Zhihong; Meng, Zhuo; Liu, Tiegen; Wang, Longzhi
2015-01-01
We present detailed measurement results of optical attenuation’s thermal coefficients (referenced to the temperature of the skin surface) in different depth regions of in vivo human forearm skins using optical coherence tomography (OCT). We first design a temperature control module with an integrated optical probe to precisely control the surface temperature of a section of human skin. We propose a method of using the correlation map to identify regions in the skin having strong correlations with the surface temperature of the skin and find that the attenuation coefficient in these regions closely follows the variation of the surface temperature without any hysteresis. We observe a negative thermal coefficient of attenuation in the epidermis. While in dermis, the slope signs of the thermal coefficient of attenuation are different at different depth regions for a particular subject, however, the depth regions with a positive (or negative) slope are different in different subjects. We further find that the magnitude of the thermal coefficient of attenuation coefficient is greater in epidermis than in dermis. We believe the knowledge of such thermal properties of skins is important for several noninvasive diagnostic applications, such as OCT glucose monitoring, and the method demonstrated in this paper is effective in studying the optical and biological properties in different regions of skin. PMID:25780740
[Atopic eczema: psychophysiological reactivity with standardized stressors].
Münzel, K; Schandry, R
1990-11-01
In 18 atopic eczema patients with active symptomatology and 15 control subjects a comparison of reactivity to psychological stressors was made. The physiological measures were heart rate, peripheral vasomotor response, skin resistance level, spontaneous fluctuations of the skin resistance, and forearm skin temperature. In addition, self-ratings of subjective state, situational anxiety, and social anxiety were assessed. Mental arithmetic performed undisturbed and in distracting conditions, and anticipation of the latter and of having to speak in public served as stressors. The results show higher reaction values of the eczema patients for heart rate, peripheral vasomotor response, fluctuations of skin resistance and subjective tension. A subgroup of patients with extreme skin irritation (itching) reacted with an elevation of skin temperature, in contrast to control subjects and patients with less marked itching, in whom skin temperature dropped slightly. The results suggest that atopic eczema may have a psychophysiological component.
Heat transfer analysis of skin during thermal therapy using thermal wave equation.
Kashcooli, Meisam; Salimpour, Mohammad Reza; Shirani, Ebrahim
2017-02-01
Specifying exact geometry of vessel network and its effect on temperature distribution in living tissues is one of the most complicated problems of the bioheat field. In this paper, the effects of blood vessels on temperature distribution in a skin tissue subjected to various thermal therapy conditions are investigated. Present model consists of counter-current multilevel vessel network embedded in a three-dimensional triple-layered skin structure. Branching angles of vessels are calculated using the physiological principle of minimum work. Length and diameter ratios are specified using length doubling rule and Cube law, respectively. By solving continuity, momentum and energy equations for blood flow and Pennes and modified Pennes bioheat equations for the tissue, temperature distributions in the tissue are measured. Effects of considering modified Pennes bioheat equation are investigated, comprehensively. It is also observed that blood has an impressive role in temperature distribution of the tissue, especially at high temperatures. The effects of different parameters such as boundary conditions, relaxation time, thermal properties of skin, metabolism and pulse heat flux on temperature distribution are investigated. Tremendous effect of boundary condition type at the lower boundary is noted. It seems that neither insulation nor constant temperature at this boundary can completely describe the real physical phenomena. It is expected that real temperature at the lower levels is somewhat between two predicted values. The effect of temperature on the thermal properties of skin tissue is considered. It is shown that considering temperature dependent values for thermal conductivity is important in the temperature distribution estimation of skin tissue; however, the effect of temperature dependent values for specific heat capacity is negligible. It is seen that considering modified Pennes equation in processes with high heat flux during low times is significant. Copyright © 2016 Elsevier Ltd. All rights reserved.
Thermal insulation and body temperature wearing a thermal swimsuit during water immersion.
Wakabayashi, Hitoshi; Hanai, Atsuko; Yokoyama, Shintaro; Nomura, Takeo
2006-09-01
This study evaluated the effects of a thermal swimsuit on body temperatures, thermoregulatory responses and thermal insulation during 60 min water immersion at rest. Ten healthy male subjects wearing either thermal swimsuits or normal swimsuits were immersed in water (26 degrees C or 29 degrees C). Esophageal temperature, skin temperatures and oxygen consumption were measured during the experiments. Metabolic heat production was calculated from oxygen consumption. Heat loss from skin to the water was calculated from the metabolic heat production and the change in mean body temperature during water immersion. Total insulation and tissue insulation were estimated by dividing the temperature difference between the esophagus and the water or the esophagus and the skin with heat loss from the skin. Esophageal temperature with a thermal swimsuit was higher than that with a normal swimsuit at the end of immersion in both water temperature conditions (p<0.05). Oxygen consumption, metabolic heat production and heat loss from the skin were less with the thermal swimsuit than with a normal swimsuit in both water temperatures (p<0.05). Total insulation with the thermal swimsuit was higher than that with a normal swimsuit due to insulation of the suit at both water temperatures (p<0.05). Tissue insulation was similar in all four conditions, but significantly higher with the thermal swimsuit in both water temperature conditions (p<0.05), perhaps due to of the attenuation of shivering during immersion with a thermal swimsuit. A thermal swimsuit can increase total insulation and reduce heat loss from the skin. Therefore, subjects with thermal swimsuits can maintain higher body temperatures than with a normal swimsuit and reduce shivering thermo-genesis.
MacRae, Braid A; Annaheim, Simon; Spengler, Christina M; Rossi, René M
2018-01-01
Background: Skin temperature ( T skin ) is commonly measured using T skin sensors affixed directly to the skin surface, although the influence of setup variables on the measured outcome requires clarification. Objectives: The two distinct objectives of this systematic review were (1) to examine measurements from contact T skin sensors considering equilibrium temperature and temperature disturbance, sensor attachments, pressure, environmental temperature, and sensor type, and (2) to characterise the contact T skin sensors used, conditions of use, and subsequent reporting in studies investigating sports, exercise, and other physical activity. Data sources and study selection: For the measurement comparison objective, Ovid Medline and Scopus were used (1960 to July 2016) and studies comparing contact T skin sensor measurements in vivo or using appropriate physical models were included. For the survey of use, Ovid Medline was used (2011 to July 2016) and studies using contact temperature sensors for the measurement of human T skin in vivo during sport, exercise, and other physical activity were included. Study appraisal and synthesis methods: For measurement comparisons, assessments of risk of bias were made according to an adapted version of the Cochrane Collaboration's risk of bias tool. Comparisons of temperature measurements were expressed, where possible, as mean difference and 95% limits of agreement (LoA). Meta-analyses were not performed due to the lack of a common reference condition. For the survey of use, extracted information was summarised in text and tabular form. Results: For measurement comparisons, 21 studies were included. Results from these studies indicated minor (<0.5°C) to practically meaningful (>0.5°C) measurement bias within the subgroups of attachment type, applied pressure, environmental conditions, and sensor type. The 95% LoA were often within 1.0°C for in vivo studies and 0.5°C for physical models. For the survey of use, 172 studies were included. Details about T skin sensor setup were often poorly reported and, from those reporting setup information, it was evident that setups widely varied in terms of type of sensors, attachments, and locations used. Conclusions: Setup variables and conditions of use can influence the measured temperature from contact T skin sensors and thus key setup variables need to be appropriately considered and consistently reported.
Perceptions of temperature, moisture and comfort in clothing during environmental transients.
Li, Y
2005-02-22
A study has been carried out to investigate the psychophysical mechanisms of the perception of temperature and moisture sensations in clothing during environmental transients. A series of wear trials was conducted to measure the psychological perception of thermal and moisture sensations and the simultaneous temperature and humidity at the skin surface, fabric surface and in the clothing under simulated moderate rain conditions. Jumpers made from wool and acrylic fibres were used in the trial. Analysis has been carried out to study the relationship between psychological perceptions of temperature and moisture and the objectively measured skin and fabric temperatures and relative humidity in clothing microclimate. The perception of warmth seems to follow Fechner's law and Stevens' power law, having positive relationships with the skin temperature and fabric temperatures. The perception of dampness appears to follow Fechner's law more closely than Stevens' power law with a negative relationship with skin temperature, and is nonlinearly and positively correlated with relative humidity in clothing microclimate. The perception of comfort is positively related to the perception of warmth and negatively to the perception of dampness. This perception of comfort is positively related to the skin temperature, which appears to follow both Fechner's law and Stevens' law, also non-linearly and negatively related to relative humidity in clothing microclimate.
[Viability and antigenic changes in the skin after preservation under different temperatures].
Ju, X; Zhu, Z; Li, C
1995-11-01
Oxygen consumption and succinate dehydrogenase contents were determined to compare mean viabilities (%) of human cadaver and guinea pig skin stored under different temperature: 4 C, -20 C, -80 C, and -196 C. The results showed that the mean viability (%) of skin cryopreserved under -196 C was superior to those under 4 C, -20 C, and -80 C (70.8%, 61% respectively for -196 C, P < 0.05 or 0.01). Microimmunoelectrophoresis and rocket immunoelectrophoresis were performed for related antigens and antibodies. The results of microimmunoelectrophoresis showed that the antigenicities were different for four groups. Antigenicity of fresh skin was highest. The higher the storage temperature, the lower the antigenicity of skin was.
NASA Astrophysics Data System (ADS)
Kim, Jae-Young; Jang, Kyungmin; Yang, Seung-Jin; Baek, Jun-Hyeok; Park, Jong-Rak; Yeom, Dong-Il; Kim, Ji-Sun; Kim, Hyung-Sik; Jun, Jae-Hoon; Chung, Soon-Cheol
2016-04-01
We studied the thermal and the mechanical effects induced by pulsed laser absorption in human skin by numerically solving the heat-transfer and the thermoelastic wave equations. The simulation of the heat-transfer equation yielded the spatiotemporal distribution of the temperature increase in the skin, which was then used in the driving term of the thermoelastic wave equation. We compared our simulation results for the temperature increase and the skin displacements with the measured and numerical results, respectively. For the comparison, we used a recent report by Jun et al. [Sci. Rep. 5, 11016 (2015)], who measured in vivo skin temperature and performed numerical simulation of the thermoelastic wave equation using a simple assumption about the temporal evolution of the temperature distribution, and found their results to be in good agreement with our results. In addition, we obtained solutions for the stresses in the human skin and analyzed their dynamic behaviors in detail.
Wheelchair cushion effect on skin temperature, heat flux, and relative humidity.
Stewart, S F; Palmieri, V; Cochran, G V
1980-05-01
For patients subject to decubitus ulcers, wheelchair cushions should be prescribed with knowledge of the cushion's effect on the thermal as well as mechanical environment of the skin. To define thermal effects that may be encountered during routine use, tests werr made on 24 commercially available cushions. Skin temperature, heat flux and relative humidity were measured under the ischial tuberosities of a normal 24-year-old man during a 1-hour period of sitting on each cushion. After 1 hour, skin temperatures increased by means of 3.4 C and 2.8 C on foams and viscoelastic foams and there were slight decreases in heat flux as compared with control values in air. On gels, skin temperatures remained constant and heat flux increased, while water "floatation" pads caused a mean skin temperature decreased of 2.7 C along with a marked increase in heat flux. Relative humidity at the skin cushion interface increased by 10.4%, 22.8% and 19.8% on foams, gels and water floatation pads, as compared with room air values. Representative cushions from each of the general types (foam, viscoelastic foam, gel and water floatation) also were subjected to 2-hour tests which indicated the measured parameters continued to change asymptotically.
Ice slurry ingestion reduces both core and facial skin temperatures in a warm environment.
Onitsuka, Sumire; Zheng, Xinyan; Hasegawa, Hiroshi
2015-07-01
Internal body cooling by ingesting ice slurry has recently attracted attention. Because ice slurries are ingested through the mouth, it is possible that this results in conductive cooling of the facial skin and brain. However, no studies have investigated this possibility. Thus, the aim of this study was to investigate the effects of ice slurry ingestion on forehead skin temperature at the point of conductive cooling between the forehead skin and brain. Eight male subjects ingested either 7.5g/kg of ice slurry (-1°C; ICE), a cold sports drink (4°C; COOL), or a warm sports drink (37°C; CON) for 15min in a warm environment (30°C, 80% relative humidity). Then, they remained at rest for 1h. As physiological indices, rectal temperature (Tre), mean skin temperature, forehead skin temperature (Thead), heart rate, nude body mass, and urine specific gravity were measured. Subjective thermal sensation (TS) was measured at 5-min intervals throughout the experiment. With ICE, Tre and Thead were significantly reduced compared with CON and COOL conditions (p<0.05). The results of the other physiological indices were not significantly different. TS with ICE was significantly lower than that with CON and COOL (p<0.05) and was correlated with Tre or Thead (p<0.05). These results indicate that ice slurry ingestion may induce conductive cooling between forehead skin and brain, and reduction in core and forehead skin temperature reduced thermal sensation. Copyright © 2015 Elsevier Ltd. All rights reserved.
THERMAL TRANSITIONS IN NORMAL AND DEUTERATED RAT-TAIL TENDON, HUMAN SKIN, AND TUNA-FISH SKIN
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rigby, B.J.
1962-07-30
The transition temperature and shrinkage temperature of collogens were determined in normal and deuterated rat-tail tendon, human skin, and tuna-fish skin. Increases were observed in the deuterated samples. Results, obtained with solid collagen, are compared with those obtained with collagen in solution. It is concluded that hydrogen bonds are involved in both reactions. (C.H.)
The use of thermal imaging to monitoring skin temperature during cryotherapy: A systematic review
NASA Astrophysics Data System (ADS)
Matos, Filipe; Neves, Eduardo Borba; Norte, Marco; Rosa, Claudio; Reis, Victor Machado; Vilaça-Alves, José
2015-11-01
Cryotherapy has been applied on clinical injuries and as a method for exercise recovery. It is aimed to reduce edema, nervous conduction velocity, and tissue metabolism, as well as to accelerate the recovery process of the muscle injury induced by exercise. Objective: This review aim to investigate the applicability of thermal imaging as a method for monitoring skin temperature during cryotherapy. Method: Search the Web of Science database using the terms "Cryotherapy", "Thermography", "Thermal Image" and "Cooling". Results: Nineteen studies met the inclusion criteria and pass the PEDro scale quality evaluation. Evidence support the use of thermal imaging as a method for monitoring the skin temperature during cryotherapy, and it is superior to other contact methods and subjective methods of assessing skin temperature. Conclusion: Thermography seems to be an efficient, trustworthy and secure method in order to monitoring skin temperature during cryotherapy application. Evidence supports the use of thermography in detriment of contact methods as well as other subjective ones.
Stress Evaluation while Prolonged Driving Operation Using the Facial Skin Temperature
NASA Astrophysics Data System (ADS)
Asano, Hirotoshi; Muto, Takumi; Ide, Hideto
There is a relation to the accident of a car and the physiological and psychological state of a driver. The stress may lead to the fall of a fatigue or attentiveness. Therefore, it is an important subject from viewpoint such as accident prevention to evaluate the mental state of a driver. The study aimed at the development of a quantitative instrumentation technology of the stress when a subject is driving for a long time. First of all, we measured the physiological and psychological stress of a driver. The facial skin temperature and ventricular rate that was driver's physiological amount were measured and compared it with visual analog scale of the subjective amount. It was able to be obtaining of the high correlation in facial skin temperature and visual analog scale from the outcome of the experiment. Therefore, the possibility of appreciable of driver's stress at a facial skin temperature was shown. As a result of the experiment, we showed a possibility that facial skin temperature could evaluate long driving stress.
Inkjet-Printed Graphene/PEDOT:PSS Temperature Sensors on a Skin-Conformable Polyurethane Substrate.
Vuorinen, Tiina; Niittynen, Juha; Kankkunen, Timo; Kraft, Thomas M; Mäntysalo, Matti
2016-10-18
Epidermal electronic systems (EESs) are skin-like electronic systems, which can be used to measure several physiological parameters from the skin. This paper presents materials and a simple, straightforward fabrication process for skin-conformable inkjet-printed temperature sensors. Epidermal temperature sensors are already presented in some studies, but they are mainly fabricated using traditional photolithography processes. These traditional fabrication routes have several processing steps and they create a substantial amount of material waste. Hence utilizing printing processes, the EES may become attractive for disposable systems by decreasing the manufacturing costs and reducing the wasted materials. In this study, the sensors are fabricated with inkjet-printed graphene/PEDOT:PSS ink and the printing is done on top of a skin-conformable polyurethane plaster (adhesive bandage). Sensor characterization was conducted both in inert and ambient atmosphere and the graphene/PEDOT:PSS temperature sensors (thermistors) were able reach higher than 0.06% per degree Celsius sensitivity in an optimal environment exhibiting negative temperature dependence.
NASA Technical Reports Server (NTRS)
Susskind, Joel; Lee, Jae N.; Iredell, Lena
2013-01-01
The AIRS Science Team Version-6 data set is a valuable resource for meteorological studies. Quality Controlled earth's surface skin temperatures are produced on a 45 km x 45 km spatial scale under most cloud cover conditions. The same retrieval algorithm is used for all surface types under all conditions. This study used eleven years of AIRS monthly mean surface skin temperature and cloud cover products to show that land surface skin temperatures have decreased significantly in some areas and increased significantly in other areas over the period September 2002 through August 2013. These changes occurred primarily at 1:30 PM but not at 1:30 AM. Cooling land areas contained corresponding increases in cloud cover over this time period, with the reverse being true for warming land areas. The cloud cover anomaly patterns for a given month are affected significantly by El Nino/La Nina activity, and anomalies in cloud cover are a driving force behind anomalies in land surface skin temperature.
Yang, Jie; Weng, Wenguo; Wang, Faming; Song, Guowen
2017-05-01
This paper aims to integrate a human thermoregulatory model with a clothing model to predict core and skin temperatures. The human thermoregulatory model, consisting of an active system and a passive system, was used to determine the thermoregulation and heat exchanges within the body. The clothing model simulated heat and moisture transfer from the human skin to the environment through the microenvironment and fabric. In this clothing model, the air gap between skin and clothing, as well as clothing properties such as thickness, thermal conductivity, density, porosity, and tortuosity were taken into consideration. The simulated core and mean skin temperatures were compared to the published experimental results of subject tests at three levels of ambient temperatures of 20 °C, 30 °C, and 40 °C. Although lower signal-to-noise-ratio was observed, the developed model demonstrated positive performance at predicting core temperatures with a maximum difference between the simulations and measurements of no more than 0.43 °C. Generally, the current model predicted the mean skin temperatures with reasonable accuracy. It could be applied to predict human physiological responses and assess thermal comfort and heat stress. Copyright © 2017 Elsevier Ltd. All rights reserved.
Relationship between skin temperature and muscle activation during incremental cycle exercise.
Priego Quesada, Jose I; Carpes, Felipe P; Bini, Rodrigo R; Salvador Palmer, Rosario; Pérez-Soriano, Pedro; Cibrián Ortiz de Anda, Rosa M
2015-02-01
While different studies showed that better fitness level adds to the efficiency of the thermoregulatory system, the relationship between muscular effort and skin temperature is still unknown. Therefore, the present study assessed the relationship between neuromuscular activation and skin temperature during cycle exercise. Ten physically active participants performed an incremental workload cycling test to exhaustion while neuromuscular activations were recorded (via surface electromyography - EMG) from rectus femoris, vastus lateralis, biceps femoris and gastrocnemius medialis. Thermographic images were recorded before, immediately after and 10 min after finishing the cycling test, at four body regions of interest corresponding to the muscles where neuromuscular activations were monitored. Frequency band analysis was conducted to assess spectral properties of EMG signals in order to infer on priority in recruitment of motor units. Significant inverse relationship between changes in skin temperature and changes in overall neuromuscular activation for vastus lateralis was observed (r<-0.5 and p<0.04). Significant positive relationship was observed between skin temperature and low frequency components of neuromuscular activation from vastus lateralis (r>0.7 and p<0.01). Participants with larger overall activation and reduced low frequency component for vastus lateralis activation presented a better adaptive response of their thermoregulatory system by showing fewer changes in skin temperature after incremental cycling test. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
1979-01-01
NASA's Ames Research Center has designed a simple but medically important device--one which holds temperature probes, called thermistors, to a person's skin without affecting the characteristics of the skin segment being measured. The device improves the accuracy of skin surface temperature measurements, valuable data in health evaluation. The need for such a device was recognized in the course of life science experiments at Ames. In earlier methods, the sensing head of the temperature probe was affixed to the patient's skin by tape or elastic bands. This created a heat variance which altered skin temperature readings. The Ames-developed thermistor holder is a plastic ring with tab extensions, shown in the upper photo on the chest, arm and leg of the patient undergoing examination. The ring holds the sensing head of the temperature probe and provides firm, constant pressure between the skin and the probe. The tabs help stabilize the ring and provide attachment points for the fastening tape or bands, which do not directly touch the sensor. With this new tool, it is possible to determine more accurately the physiological effects of strenuous exercise, particularly on the treadmill. The holder is commercially available from Yellow Springs Instrument Company, Inc., Yellow Springs, Ohio, which is producing the device under a NASA patent license.
Souza-Barros, Leanna; Dhaidan, Ghaith; Maunula, Mikko; Solomon, Vaeda; Gabison, Sharon; Lilge, Lothar; Nussbaum, Ethne L
2018-04-01
To examine the role of skin color and tissue thickness on transmittance, reflectance, and skin heating using red and infrared laser light. Forty volunteers were measured for skin color and skin-fold thickness at a standardized site near the elbow. Transmittance, reflectance and skin temperature were recorded for energy doses of 2, 6, 9, and 12 Joules using 635 nm (36 mW) and 808 nm (40 mW) wavelength laser diodes with irradiances within American National Standards Institute safety guidelines (4.88 mm diameter, 0.192 W/cm 2 and 4.88 mm diameter, 0.214 W/cm 2 , respectively). The key factors affecting reflectance to an important degree were skin color and wavelength. However, the skin color effects were different for the two wavelengths: reflectance decreased for darker skin with a greater decrease for red light than near infrared light. Transmittance was greater using 808 nm compared with 635 nm. However, the effect was partly lost when the skin was dark rather than light, and was increasingly lost as tissue thickness increased. Dose had an increasing effect on temperature (0.7-1.6°C across the 6, 9, and 12 J doses); any effects of wavelength, skin color, and tissue thickness were insignificant compared to dose effects. Subjects themselves were not aware of the increased skin temperature. Transmittance and reflectance changes as a function of energy were very small and likely of no clinical significance. Absorption did not change with higher energy doses and increasing temperature. Skin color and skin thickness affect transmittance and reflectance of laser light and must be accounted for when selecting energy dose to ensure therapeutic effectiveness at the target tissue. Skin heating appears not to be a concern when using 635 and 808 nm lasers at energy doses of up to 12 J and irradiance within American National Standards Institute standards. Photobiomodulation therapy should never exceed the American National Standards Institute recommendation for the maximum permissible exposure to the skin. Lasers Surg. Med. 50:291-301, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
The Environment and the Microbial Ecology of Human Skin
McBride, Mollie E.; Duncan, W. Christopher; Knox, J. M.
1977-01-01
Microbial flora of the skin of three human population groups representing different natural environments was examined quantitatively and qualitatively to determine whether environmental differences in temperature and humidity can influence the microbial flora of normal skin. Five anatomical skin sites - hands, back, axillae, groin, and feet - were sampled from 10 subjects working in a high-humidity, high-temperature environment, 10 subjects from a low-temperature, high-humidity environment, and 10 subjects working in a moderate-temperature and low-humidity environment. Bacterial populations were significantly larger from the back, axillae, and feet in individuals from the high-temperature and high-humidity environment as compared to the moderate-temperature, low-humidity environment. High humidity and low temperature had no significant effect on total populations, but this group showed a higher frequency of isolation of fungi, and gram-negative bacteria from the back and feet. Although there was an indication that increase in the environmental humidity could result in an increased frequency of isolation of gram-negative bacteria, there was no evidence that an increase in either temperature or humidity altered the relative proportions of gram-negative bacteria in the predominantly gram-positive microbial flora found on normal skin. It was concluded that, although climatic changes may cause fluctation in microbial populations from certain sites, they are not a major influence on the ecology of the microbial flora of normal skin in the natural environment. The variables introduced by studying individuals in their natural environment and the influence of these on the results are discussed. PMID:16345214
Abdoun, Khalid A; Samara, Emad M; Okab, Aly B; Al-Haidary, Ahmed A
2012-07-01
It was the aim of this study to investigate the regional variations in surface temperature and sweating rate and to visualize body thermal windows responsible for the dissipation of excess body heat in dromedary camels. This study was conducted on five dromedary camels with mean body weight of 450 ± 20.5 kg and 2 years of age. Sweating rate, skin and body surface temperature showed significant (P < 0.001) circadian variation together with the variation in ambient temperature. However, daily mean values of sweating rate, skin and body surface temperature measured on seven regions of the camel body did not significantly differ. The variation in body surface temperature compared to the variation in skin temperature was higher in the hump compared to the axillary and flank regions, indicating the significance of camel's fur in protecting the skin from daily variation in ambient temperature. Infrared thermography revealed that flank and axillary regions had lower thermal gradients at higher ambient temperature (T(a) ) and higher thermal gradients at lower T(a) , which might indicate the working of flank and axillary regions as thermal windows dissipating heat during the night. Sweating rate showed moderate correlation to skin and body surface temperatures, which might indicate their working as potential thermal drivers of sweating in camels. © 2012 The Authors. Animal Science Journal © 2012 Japanese Society of Animal Science.
Energy exchanges of swimming man
NASA Technical Reports Server (NTRS)
Nadel, E. R.; Holmer, I.; Bergh, U.; Astrand, P.-O.; Stolwijk, J. A. J.
1974-01-01
Three male swimmers underwent 10-min resting and 20-min swimming (breaststroke) exposures in a swimming flume. Water temperatures in separate exposures were 18, 26, and 33 C. At each water temperature the subjects rested and swam at water velocities of 0.50, 0.75, and 0.95 m/sec, which were designed to produce around 40, 70, and 100% of maximal aerobic power. Measurements were made of esophageal temperature, four skin temperatures, water temperature, heat flow from five local skin surfaces (Hatfield-Turner disks), and oxygen uptake. Calculations were made of mean area-weighted skin temperature and heat flow, metabolic rate, and heat storage. Internal body temperature changes after 20 min of swimming were related to water temperature, swimming intensity, and body composition.
Gowrishankar, T R; Stewart, Donald A; Martin, Gregory T; Weaver, James C
2004-11-17
Investigation of bioheat transfer problems requires the evaluation of temporal and spatial distributions of temperature. This class of problems has been traditionally addressed using the Pennes bioheat equation. Transport of heat by conduction, and by temperature-dependent, spatially heterogeneous blood perfusion is modeled here using a transport lattice approach. We represent heat transport processes by using a lattice that represents the Pennes bioheat equation in perfused tissues, and diffusion in nonperfused regions. The three layer skin model has a nonperfused viable epidermis, and deeper regions of dermis and subcutaneous tissue with perfusion that is constant or temperature-dependent. Two cases are considered: (1) surface contact heating and (2) spatially distributed heating. The model is relevant to the prediction of the transient and steady state temperature rise for different methods of power deposition within the skin. Accumulated thermal damage is estimated by using an Arrhenius type rate equation at locations where viable tissue temperature exceeds 42 degrees C. Prediction of spatial temperature distributions is also illustrated with a two-dimensional model of skin created from a histological image. The transport lattice approach was validated by comparison with an analytical solution for a slab with homogeneous thermal properties and spatially distributed uniform sink held at constant temperatures at the ends. For typical transcutaneous blood gas sensing conditions the estimated damage is small, even with prolonged skin contact to a 45 degrees C surface. Spatial heterogeneity in skin thermal properties leads to a non-uniform temperature distribution during a 10 GHz electromagnetic field exposure. A realistic two-dimensional model of the skin shows that tissue heterogeneity does not lead to a significant local temperature increase when heated by a hot wire tip. The heat transport system model of the skin was solved by exploiting the mathematical analogy between local thermal models and local electrical (charge transport) models, thereby allowing robust, circuit simulation software to obtain solutions to Kirchhoff's laws for the system model. Transport lattices allow systematic introduction of realistic geometry and spatially heterogeneous heat transport mechanisms. Local representations for both simple, passive functions and more complex local models can be easily and intuitively included into the system model of a tissue.
STS-132 crew during their PDRS N-TSK MRM training in the building 16 cupola trainer.
2009-12-22
JSC2009-E-286974 (22 Dec. 2009) --- Astronauts Ken Ham (left background), STS-132 commander; Tony Antonelli (right background), pilot; and Mike Good, mission specialist, participate in an exercise in the systems engineering simulator in the Avionics Systems Laboratory at NASA?s Johnson Space Center. The facility includes moving scenes of full-sized International Space Station components over a simulated Earth.
STS-132 crew during their PDRS N-TSK MRM training in the building 16 cupola trainer.
2009-12-22
JSC2009-E-286962 (22 Dec. 2009) --- Astronauts Ken Ham (right background), STS-132 commander; Tony Antonelli (left), pilot; and Mike Good, mission specialist, participate in an exercise in the systems engineering simulator in the Avionics Systems Laboratory at NASA?s Johnson Space Center. The facility includes moving scenes of full-sized International Space Station components over a simulated Earth.
STS-132 crew during their PDRS N-TSK MRM training in the building 16 cupola trainer.
2009-12-22
JSC2009-E-286976 (22 Dec. 2009) --- Astronauts Ken Ham (left), STS-132 commander; Tony Antonelli (right background), pilot; and Mike Good, mission specialist, participate in an exercise in the systems engineering simulator in the Avionics Systems Laboratory at NASA?s Johnson Space Center. The facility includes moving scenes of full-sized International Space Station components over a simulated Earth.
STS-132 crew during their PDRS N-TSK MRM training in the building 16 cupola trainer.
2009-12-22
JSC2009-E-286972 (22 Dec. 2009) --- Astronauts Ken Ham (right background), STS-132 commander; Tony Antonelli (left), pilot; and Mike Good, mission specialist, participate in an exercise in the systems engineering simulator in the Avionics Systems Laboratory at NASA?s Johnson Space Center. The facility includes moving scenes of full-sized International Space Station components over a simulated Earth.
Of Ballots and Bullets: Explaining Civilian Control of the Military in Turkey, 2002-2011
2014-09-01
had failed? Using the theory of electoral competition, this dissertation demonstrates the link between elections and policy making, and how together...AKP succeed where other political parties had failed? Using the theory of electoral competition, this dissertation demonstrates the link between...between the AKP and the TSK are informed by a variety of theories , electoral competition and the incentive structure created by elections best explains
Roelofs, Jeffrey; Peters, Madelon L; Fassaert, Thijs; Vlaeyen, Johan W S
2005-05-01
The present study sought to investigate to what extent patients with chronic low back pain and pain-free control subjects selectively attend to pain-related stimuli as measured with 2 dot-probe tasks with word stimuli and pictorial stimuli. Selective attentional processing was measured by means of 3 indices: the bias index, a congruency effect, and an incongruency effect. Pain-related fear as a trait measure (Tampa Scale for Kinesiophobia [TSK]) was expected to be positively associated with all indices of selective attentional processing of pain stimuli. Results were analyzed with repeated-measures analysis of variance. An incongruency effect was found for patients and to a significantly less degree for pain-free control subjects on the dot-probe task with pictorial stimuli, indicating that pain patients have difficulty disengaging from threat pictures. Pain-related fear as a trait measure (TSK) was not associated with selective attentional processing of word and pictorial stimuli in either pain patients or control subjects. Results from the present study are discussed, and directions for future research are provided. Demonstrating difficulty to disengage from threat might be clinically relevant because patients might pay less attention to fear-disconfirming information and remain engaged in avoidance, which might eventually lead to prolonged anxiety states.
SVR versus neural-fuzzy network controllers for the sagittal balance of a biped robot.
Ferreira, João P; Crisóstomo, Manuel M; Coimbra, A Paulo
2009-12-01
The real-time balance control of an eight-link biped robot using a zero moment point (ZMP) dynamic model is difficult due to the processing time of the corresponding equations. To overcome this limitation, two alternative intelligent computing control techniques were compared: one based on support vector regression (SVR) and another based on a first-order Takagi-Sugeno-Kang (TSK)-type neural-fuzzy (NF) network. Both methods use the ZMP error and its variation as inputs and the output is the correction of the robot's torso necessary for its sagittal balance. The SVR and the NF were trained based on simulation data and their performance was verified with a real biped robot. Two performance indexes are proposed to evaluate and compare the online performance of the two control methods. The ZMP is calculated by reading four force sensors placed under each robot's foot. The gait implemented in this biped is similar to a human gait that was acquired and adapted to the robot's size. Some experiments are presented and the results show that the implemented gait combined either with the SVR controller or with the TSK NF network controller can be used to control this biped robot. The SVR and the NF controllers exhibit similar stability, but the SVR controller runs about 50 times faster.
Comparison of infrared thermometer with thermocouple for monitoring skin temperature.
Matsukawa, T; Ozaki, M; Nishiyama, T; Imamura, M; Kumazawa, T
2000-02-01
To test the hypothesis that the infrared thermometer (Genius) is comparably useful with thermocouples that are routinely used for skin temperature monitoring. Prospective, controlled, not blinded study. Operating room of a university hospital. Ten healthy male volunteers. Volunteers were minimally clothed and were initially warmed by a forced air warmer until they became vasodilated at the finger and the foot for approximately 30 mins. Subsequently, they were kept in the room with no blanket. Skin temperatures were measured continuously with the Mon-a-Therm thermocouple and were also measured with the Genius thermometer just before and after the warming and subsequently every 10 mins for 70 mins. Forearm and finger-tip skin temperatures and skin-surface temperature gradients (from arm to finger and from calf to toe) measured by the Genius thermometer were compared with those measured by the Mon-a-Therm thermocouple using linear regression and Bland and Altman statistics. Forearm temperature and finger-tip temperature ranged from approximately 31 degrees to approximately 36.5 degrees C (87.8-97.7 degrees F) and approximately 22.5 degrees to approximately 36 degrees C (72.5-96.8 degrees F), respectively. Gradients (from arm to finger and from calf to toe) ranged from approximately -3 degrees to approximately 10 degrees C (26.6-50.0 degrees F) and approximately -3 degrees to approximately 11 degrees C (26.6-51.8 degrees F), respectively. Correlations between the temperatures measured by the Genius thermometer and those by the Mon-a-Therm thermocouple were similar and reliable. The correlation coefficients were as follows: 0.78 at forearm, 0.97 at finger-tip, and 0.97 at skin-surface temperature gradients. The infrared thermometer with a special probe is useful to measure the change of skin-surface temperatures and to evaluate the severity of shock in patients.
Modeling Burns for Pre-Cooled Skin Flame Exposure
2017-01-01
On a television show, a pre-cooled bare-skinned person (TV host) passed through engulfing kerosene flames. The assumption was that a water film should protect him during 0.74 s flame exposure in an environment of 86 kW/m2 heat flux. The TV host got light burn inflammation on the back, arms and legs. The present work studies skin temperatures and burn damage integral of such dangerous flame exposure. The skin temperature distribution during water spray pre-cooling, transport to the flames, flame exposure, transport to the water pool, and final water pool cooling is modelled numerically. Details of the temperature development of the skin layers are presented, as well as the associated damage integral. It is shown that 5 °C water spray applied for a 30 s period pre-cooled the skin sufficiently to prevent severe skin injury. Soot marks indicate that the water layer evaporated completely in some areas resulting in skin flame contact. This exposed dry skin directly to the flames contributing significantly to the damage integral. It is further analyzed how higher water temperature, shorter pre-cooling period or longer flame exposure influence the damage integral. It is evident that minor changes in conditions could lead to severe burns and that high heat flux levels at the end of the exposure period are especially dangerous. This flame stunt should never be repeated. PMID:28880253
Validation of the thermophysiological model by Fiala for prediction of local skin temperatures
NASA Astrophysics Data System (ADS)
Martínez, Natividad; Psikuta, Agnes; Kuklane, Kalev; Quesada, José Ignacio Priego; de Anda, Rosa María Cibrián Ortiz; Soriano, Pedro Pérez; Palmer, Rosario Salvador; Corberán, José Miguel; Rossi, René Michel; Annaheim, Simon
2016-12-01
The most complete and realistic physiological data are derived from direct measurements during human experiments; however, they present some limitations such as ethical concerns, time and cost burden. Thermophysiological models are able to predict human thermal response in a wide range of environmental conditions, but their use is limited due to lack of validation. The aim of this work was to validate the thermophysiological model by Fiala for prediction of local skin temperatures against a dedicated database containing 43 different human experiments representing a wide range of conditions. The validation was conducted based on root-mean-square deviation (rmsd) and bias. The thermophysiological model by Fiala showed a good precision when predicting core and mean skin temperature (rmsd 0.26 and 0.92 °C, respectively) and also local skin temperatures for most body sites (average rmsd for local skin temperatures 1.32 °C). However, an increased deviation of the predictions was observed for the forehead skin temperature (rmsd of 1.63 °C) and for the thigh during exercising exposures (rmsd of 1.41 °C). Possible reasons for the observed deviations are lack of information on measurement circumstances (hair, head coverage interference) or an overestimation of the sweat evaporative cooling capacity for the head and thigh, respectively. This work has highlighted the importance of collecting details about the clothing worn and how and where the sensors were attached to the skin for achieving more precise results in the simulations.
Buis, Arjan
2016-01-01
Elevated skin temperature at the body/device interface of lower-limb prostheses is one of the major factors that affect tissue health. The heat dissipation in prosthetic sockets is greatly influenced by the thermal conductive properties of the hard socket and liner material employed. However, monitoring of the interface temperature at skin level in lower-limb prosthesis is notoriously complicated. This is due to the flexible nature of the interface liners used which requires consistent positioning of sensors during donning and doffing. Predicting the residual limb temperature by monitoring the temperature between socket and liner rather than skin and liner could be an important step in alleviating complaints on increased temperature and perspiration in prosthetic sockets. To predict the residual limb temperature, a machine learning algorithm – Gaussian processes is employed, which utilizes the thermal time constant values of commonly used socket and liner materials. This Letter highlights the relevance of thermal time constant of prosthetic materials in Gaussian processes technique which would be useful in addressing the challenge of non-invasively monitoring the residual limb skin temperature. With the introduction of thermal time constant, the model can be optimised and generalised for a given prosthetic setup, thereby making the predictions more reliable. PMID:27695626
Mathur, Neha; Glesk, Ivan; Buis, Arjan
2016-06-01
Elevated skin temperature at the body/device interface of lower-limb prostheses is one of the major factors that affect tissue health. The heat dissipation in prosthetic sockets is greatly influenced by the thermal conductive properties of the hard socket and liner material employed. However, monitoring of the interface temperature at skin level in lower-limb prosthesis is notoriously complicated. This is due to the flexible nature of the interface liners used which requires consistent positioning of sensors during donning and doffing. Predicting the residual limb temperature by monitoring the temperature between socket and liner rather than skin and liner could be an important step in alleviating complaints on increased temperature and perspiration in prosthetic sockets. To predict the residual limb temperature, a machine learning algorithm - Gaussian processes is employed, which utilizes the thermal time constant values of commonly used socket and liner materials. This Letter highlights the relevance of thermal time constant of prosthetic materials in Gaussian processes technique which would be useful in addressing the challenge of non-invasively monitoring the residual limb skin temperature. With the introduction of thermal time constant, the model can be optimised and generalised for a given prosthetic setup, thereby making the predictions more reliable.
Forriez, O; Masseline, J; Coadic, D; David, V; Trouiller, P; Sztrymf, B
2017-02-02
To test the effect of a new coverlet device, allowing air circulation at the body/underlying surface interface, on skin microclimate management. This prospective observational pilot study took place in a 15-bed university-affiliated intensive care unit. Overall, 34 mechanically ventilated patients were included. Skin humidity and temperature were monitored before and after the implementation of the tested device at the occiput, scapulas, buttocks and sacrum. Humidity and temperature were evaluated through surface skin impedance and an infra-red thermometer, respectively. Health professionals were asked to evaluate the device. After implementation of the coverlet device, there was a rapid, sustained and significant decrease in skin humidity at all sites ranging from 6 % to 15 %, excluding the occiput. Skin temperature also significantly decreased from 1 % at both scapulas, but not at the other studied body sites. No side effects were observed. Health professionals reported that the device was easy and quick to install. Although they did not report a subjective improvement in skin moisture or temperature, they considered the device to be efficient. Although limited by its design, this pilot study suggests a good efficacy of the studied device on skin microclimate management. Further data are warranted to test the clinical implications of our findings.
Skin temperature response to cryotherapy.
Chesterton, Linda S; Foster, Nadine E; Ross, Lesley
2002-04-01
To compare the localized skin-cooling effects of 2 cryotherapy modalities and to review the clinical relevance of the results. Randomized controlled trial with repeated measures. Laboratory experiment. Convenience sample of 20 volunteers (13 women, 7 men), ages 21.3 to 44 years (mean, 31.3 +/- 6.8 y). A flexible frozen gel pack, a 454 g packet of frozen peas, or a control applied to the anterior thigh. No blinding was undertaken. Surface skin temperature under the modality at baseline and 10 and 20 minutes after application. Significant effects were recorded for modality (F(2) = 290.56, P <.0001), time (F(1.27) = 1868.07, P <.0001), and their interaction (F(2.09) = 305.47, P <.0001). After 20 minutes, frozen peas produced the lowest mean skin temperature +/- standard deviation of 10.8 degrees C +/- 2.28 degrees C compared with 14.4 degrees C +/- 2.53 degrees C from the gel pack and 26.1 degrees C +/- 1.75 degrees C from the control. Skin temperature fell between both time periods with the application of frozen peas but stabilized after 10 minutes of gel pack and control application. Application of frozen peas produced mean skin temperatures adequate to induce localized skin analgesia, to reduce nerve conduction velocity, and to reduce metabolic enzyme activity to clinically relevant levels. Flexible frozen gel packs did not cool skin sufficiently to achieve these levels. Copyright 2002 by the American Congress of Rehabilitation Medicine and the American Academy of Physical Medicine and Rehabilitation
2016-01-01
Physical stability of synthetic skin samples during their exposure to microwave heating was investigated to demonstrate the use of the metal-assisted and microwave-accelerated decrystallization (MAMAD) technique for potential biomedical applications. In this regard, optical microscopy and temperature measurements were employed for the qualitative and quantitative assessment of damage to synthetic skin samples during 20 s intermittent microwave heating using a monomode microwave source (at 8 GHz, 2–20 W) up to 120 s. The extent of damage to synthetic skin samples, assessed by the change in the surface area of skin samples, was negligible for microwave power of ≤7 W and more extensive damage (>50%) to skin samples occurred when exposed to >7 W at initial temperature range of 20–39 °C. The initial temperature of synthetic skin samples significantly affected the extent of change in temperature of synthetic skin samples during their exposure to microwave heating. The proof of principle use of the MAMAD technique was demonstrated for the decrystallization of a model biological crystal (l-alanine) placed under synthetic skin samples in the presence of gold nanoparticles. Our results showed that the size (initial size ∼850 μm) of l-alanine crystals can be reduced up to 60% in 120 s without damage to synthetic skin samples using the MAMAD technique. Finite-difference time-domain-based simulations of the electric field distribution of an 8 GHz monomode microwave radiation showed that synthetic skin samples are predicted to absorb ∼92.2% of the microwave radiation. PMID:27917407
Okutsu, I
1982-05-01
Blood circulation must be carefully evaluated following the microvascular anastomosis, such replantation of the digits and hands, free toe-to-hand transfer, and free flaps. From May 173, we have performed replantation of forty-five digits, seven wrists or forearm in thirty-four patients and one leg in one patient. The overall survival rate was 92.5%, including near total amputation. Also, from May 1974, we have performed eleven free flaps or free musculocutaneous flaps in ten patients. Seven out of eleven free flaps survived without any problems. The clinical inspections such as skin color and capillary refill are of subjective nature, and not always reliable. Therefore, from 1974, we have been measuring the skin temperature in the revascularized parts by means of a thermister. We usually use an electric blanket to warm the proximal part of the operated limb to maintain the peripheral circulation. Under normal ward environment, we analyzed the patterns of temperature fluctuations, and compared them against the revascularized parts and control sites. On our animal experiments, with the rats' hind limbs, a drastic temperature drop by about 2.0 degrees C was observed in 30 min, compared against the control group, when either artery or vein or both were obstructed. In the cases of the replantations, the skin temperature of control digits ranged from 30.4 to 37.1 degrees C. It usually remained above 32.0 degrees, fluctuating within 3 degrees. Also the skin temperatures of the successfully replanted parts and free flaps usually indicated the level above 32.0 degrees C, which corresponds to more than 80% of the axillary temperature in replanted cases and 90% in free flaps. In one failure case of replantation, the skin temperature fluctuated fom 27.2 to 32.1 degrees. On the fifth post operative day, the temperature suddenly dropped by 5 degrees in two hours. Arteriography was performed, and the arterial obstruction was confirmed. For the four flap operations, the skin temperatures had dropped below 32.0 degrees C, of which two had recovered by an auto-vein graft and the removal of haematoma respectively. We have concluded from these results, that the critical skin temperature in replantation and free flap cases was apparently above 32.0 degrees C in the normal ward environment. Based on our experiences, we have designed a continuous skin temperature monitoring device which consists of a resistance bridge and a thermister. The power source is a D.C. 12V. A high accuracy is maintained at the range of 32.1 +/- 0.3 degrees C when the system is set at 32.0 degrees C in the ward. The circuit is designed to flash a blue lamp when the temperature of the operated site is maintained above the pre-established temperature, while a red lamp and buzz signal give a warning when the temperature drops below the pre-established temperature. This equipment and skin thermometer have been simultaneously used following the various operations of microvascular anastomoses...
Wakabayashi, Hitoshi; Wijayanto, Titis; Lee, Joo-Young; Hashiguchi, Nobuko; Saat, Mohamed; Tochihara, Yutaka
2011-07-01
This study investigated the differences in heat dissipation response to intense heat stress during exercise in hot and humid environments between tropical and temperate indigenes with matched physical characteristics. Ten Japanese (JP) and ten Malaysian (MY) males participated in this study. Subjects performed exercise for 60 min at 55% peak oxygen uptake in 32°C air with 70% relative humidity, followed by 30 min recovery. The increase in rectal temperature (T(re)) was smaller in MY during exercise compared to JP. The local sweat rate and total body mass loss were similar in both groups. Both skin blood flow and mean skin temperature was lower in MY compared to JP. A significantly greater increase in hand skin temperature was observed in MY during exercise, which is attributable to heat loss due to the greater surface area to mass ratio and large number of arteriovenous anastomoses. Also, the smaller increase in T(re) in MY may be explained by the presence of a significantly greater core-skin temperature gradient in MY than JP. The thermal gradient is also a major factor in increasing the convective heat transfer from core to skin as well as skin blood flow. It is concluded that the greater core-skin temperature gradient observed in MY is responsible for the smaller increase in T(re).
Skin temperature increase mediated by wearable, long duration, low-intensity therapeutic ultrasound
NASA Astrophysics Data System (ADS)
Langer, Matthew D.; Huang, Wenyi; Ghanem, Angi; Guo, Yuan; Lewis, George K.
2017-03-01
One of the safety concerns with the delivery of therapeutic ultrasound is overheating of the transducer-skin interface due to poor or improper coupling. The objective of this research was to define a model that could be used to calculate the heating in the skin as a result of a novel, wearable long-duration ultrasound device. This model was used to determine that the maximum heating in the skin remained below the minimum threshold necessary to cause thermal injury over multiple hours of use. In addition to this model data, a human clinical study used wire thermocouples on the skin surface to measure heating characteristics during treatment with the sustained ultrasound system. Parametric analysis of the model determined that the maximum temperature increase is at the surface of the skin ranged from 40-41.8° C when perfusion was taken into account. The clinical data agreed well with the model predictions. The average steady state temperature observed across all 44 subjects was 40°C. The maximum temperature observed was less than 44° C, which is clinically safe for over 5 hours of human skin contact. The resultant clinical temperature data paired well with the model data suggesting the model can be used for future transducer and ultrasound system design simulation. As a result, the device was validated for thermal safety for typical users and use conditions.
NASA Astrophysics Data System (ADS)
Adolph, A. C.; Albert, M. R.; Hall, D. K.
2017-12-01
As rapid warming of the Arctic occurs, it is imperative that we monitor climate parameters such as temperature over large areas to understand and predict the extent of climate changes. Temperatures are often tracked using in-situ 2 m air temperatures, but in remote locations such as on the Greenland Ice Sheet, temperature can be studied more comprehensively using remote sensing techniques. Because of the presence of surface-based temperature inversions in ice-covered areas, differences between 2 m air temperature and skin temperature can be significant and are particularly relevant when considering validation and application of remote sensing temperature data. We present results from a field campaign at Summit Station in Greenland to study surface temperature using the following measurements: skin temperature measured by IR sensors, thermochrons, and thermocouples; 2 m air temperature measured by a NOAA meteorological station; and two different MODerate-resolution Imaging Spectroradiometer (MODIS) surface temperature products. We confirm prior findings that in-situ 2 m air temperature is often significantly higher in the summer than in-situ skin temperature when incoming solar radiation and wind speed are low. This inversion may account for biases in previous MODIS surface temperature studies that used 2 m air temperature for validation. As compared to the in-situ IR skin temperature measurements, the MOD/MYD11 Collection 6 surface-temperature standard product has an RMSE of 1.0°C, and that the MOD29 Collection 6 product has an RMSE of 1.5°C, spanning a range of temperatures from -35°C to -5°C. For our study area and time series, MODIS surface temperature products agree with skin temperatures better than many previous studies have indicated, especially at temperatures below -20°C where other studies found a significant cold bias. Further investigation at temperatures below -35°C is warranted to determine if this bias does indeed exist.
Characteristics of the local cutaneous sensory thermoneutral zone
Zhang, Hui; Arens, Edward A.
2017-01-01
Skin temperature detection thresholds have been used to measure human cold and warm sensitivity across the temperature continuum. They exhibit a sensory zone within which neither warm nor cold sensations prevail. This zone has been widely assumed to coincide with steady-state local skin temperatures between 32 and 34°C, but its underlying neurophysiology has been rarely investigated. In this study we employ two approaches to characterize the properties of sensory thermoneutrality, testing for each whether neutrality shifts along the temperature continuum depending on adaptation to a preceding thermal state. The focus is on local spots of skin on the palm. Ten participants (age: 30.3 ± 4.8 yr) underwent two experiments. Experiment 1 established the cold-to-warm inter-detection threshold range for the palm’s glabrous skin and its shift as a function of 3 starting skin temperatures (26, 31, or 36°C). For the same conditions, experiment 2 determined a thermally neutral zone centered around a thermally neutral point in which thermoreceptors’ activity is balanced. The zone was found to be narrow (~0.98 to ~1.33°C), moving with the starting skin temperature over the temperature span 27.5–34.9°C (Pearson r = 0.94; P < 0.001). It falls within the cold-to-warm inter-threshold range (~2.25 to ~2.47°C) but is only half as wide. These findings provide the first quantitative analysis of the local sensory thermoneutral zone in humans, indicating that it does not occur only within a specific range of steady-state skin temperatures (i.e., it shifts across the temperature continuum) and that it differs from the inter-detection threshold range both quantitatively and qualitatively. These findings provide insight into thermoreception neurophysiology. NEW & NOTEWORTHY Contrary to a widespread concept in human thermoreception, we show that local sensory thermoneutrality is achievable outside the 32–34°C skin temperature range. We propose that sensory adaption underlies a new mechanism of temperature integration. Also, we have developed from vision research a new quantitative test addressing the balance in activity of cutaneous cold and warm thermoreceptors. This could have important clinical (assessment of somatosensory abnormalities in neurological disease) and applied (design of personal comfort systems) implications. PMID:28148644
Infrared thermography in newborns: the first hour after birth.
Christidis, Iris; Zotter, Heinz; Rosegger, Hellfried; Engele, Heidi; Kurz, Ronald; Kerbl, Reinhold
2003-01-01
It was the aim of this study to investigate the surface temperature in newborns within the first hour after delivery. Furthermore, the influence of different environmental conditions with regard to surface temperature was documented. Body surface temperature was recorded under several environmental conditions by use of infrared thermography. 42 newborns, all delivered at term and with weight appropriate for date, were investigated under controlled conditions. The surface temperature immediately after birth shows a uniform picture of the whole body; however, it is significantly lower than the core temperature. Soon after birth, peripheral sites become cooler whereas a constant temperature is maintained at the trunk. Bathing in warm water again leads to a more even temperature profile. Radiant heaters and skin-to-skin contact with the mother are both effective methods to prevent heat loss in neonates. Infrared thermography is a simple and reliable tool for the measurement of skin temperature profiles in neonates. Without the need of direct skin contact, it may be helpful for optimizing environmental conditions at delivery suites and neonatal intensive-care units. Copyright 2003 S. Karger AG, Basel
Habituation of the metabolic and ventilatory responses to cold-water immersion in humans.
Tipton, Michael J; Wakabayashi, Hitoshi; Barwood, Martin J; Eglin, Clare M; Mekjavic, Igor B; Taylor, Nigel A S
2013-01-01
An experiment was undertaken to answer long-standing questions concerning the nature of metabolic habituation in repeatedly cooled humans. It was hypothesised that repeated skin and deep-body cooling would produce such a habituation that would be specific to the magnitude of the cooling experienced, and that skin cooling alone would dampen the cold-shock but not the metabolic response to cold-water immersion. Twenty-one male participants were divided into three groups, each of which completed two experimental immersions in 12°C water, lasting until either rectal temperature fell to 35°C or 90min had elapsed. Between these two immersions, the control group avoided cold exposures, whilst two experimental groups completed five additional immersions (12°C). One experimental group repeatedly immersed for 45min in average, resulting in deep-body (1.18°C) and skin temperature reductions. The immersions in the second experimental group were designed to result only in skin temperature reductions, and lasted only 5min. Only the deep-body cooling group displayed a significantly blunted metabolic response during the second experimental immersion until rectal temperature decreased by 1.18°C, but no habituation was observed when they were cooled further. The skin cooling group showed a significant habituation in the ventilatory response during the initial 5min of the second experimental immersion, but no alteration in the metabolic response. It is concluded that repeated falls of skin and deep-body temperature can habituate the metabolic response, which shows tissue temperature specificity. However, skin temperature cooling only will lower the cold-shock response, but appears not to elicit an alteration in the metabolic response. Copyright © 2012 Elsevier Ltd. All rights reserved.
Prediction of threshold pain skin temperature from thermal properties of materials in contact.
Stoll, A M; Chianta, M A; Piergallini, J R
1982-12-01
Aerospace design engineers have long sought concrete data with respect to the thermal safety of materials in contact with human skin. A series of studies on this subject has been completed and some of the results have been reported earlier. In these studies over 2,000 observations were made of pain threshold during contact with materials at elevated temperatures. Six materials were used representing the full range of thermal properties from good conductors to good insulators. Previous reports gave methods for determining the maximum permissible temperatures for any material in safe contact with bare skin for 1-5 s solely from a knowledge of its thermal properties. This report presents the comparison of the theoretical and experimental contact temperatures at pain threshold and provides a method for deriving the skin temperature productive of threshold pain from the thermal properties of any material within the range of those studies. Ratios reflecting the heat transfer coefficient associated with the materials in contact are related to their thermal properties so that the skin temperature at pain threshold may be determined from that calculated from heat transfer theory. Tabular and graphical representation of these data permits interpolation within the range of properties so that any material of known thermal conductivity, density and specific heat may be assessed with respect to its effect on the skin temperature during contact to the end point of pain. These data, in conjunction with those already reported, constitute a system for the complete assessment of the thermal aspects of practically any material suitable for construction and manufacturing applications with respect to safe contact with human skin.
NASA Astrophysics Data System (ADS)
Neves, Eduardo Borba; Cunha, Raphael Martins; Rosa, Claudio; Antunes, Natacha Sousa; Felisberto, Ivo Miguel Vieira; Vilaça-Alves, José; Reis, Victor Machado
2016-03-01
It was known that the thermal response varies according to some variables. Until now, there are no studies that have investigated the relationship of skin temperature and heart rate during and after the workout, either the thermal behavior during postural changes. Objective: the aim of this study was to evaluate the behavior of skin temperature and heart rate, during exercise and up to an hour of recovery (with postural change), performed in two different intensities sessions (70% and 85% of 10 repetitions maximum) and observe the correlation between them. Method: This was a short longitudinal study, carried out with women aged from 18 to 30 years. A sample of 31 untrained women, aged 18 and 30 was used. The volunteers were randomized into two groups: Biceps Group (BG), with 15 women, and Quadriceps Group (QG) with 16 women. Results: During and after completion of the exercise session, there was a significant reduction in skin temperature on the active muscles in both groups (BG and QG), with similar thermal responses for the two intensities studied (70% and 85%) to the minute 15 (which marks the end of the recovery in the standing position). From minute 15 to minute 20-60, the skin temperature increases abruptly and significantly, returning to levels close to those observed before exercise. Conclusion: There were no statistical differences in thermal response to exercises in 70% or 85% of 10RM. There is a negative correlation between heart rate and skin temperature when untrained women perform anaerobic exercise. It was observed that after a change of posture (from a standing position to a sitting posture) skin temperature increased abruptly and significantly.
THERMAL COMFORT IN RELATION TO MEAN SKIN TEMPERATURE,
Nude men were exposed to a range of ambient temperatures and were brought to a condition of thermal comfort by adjustment of the incident radiation...was evident that mean skin temperature, per se, was not a dependable criterion of thermal comfort . (Author)
The effects of body thermal state on manual performance.
DOT National Transportation Integrated Search
1968-05-01
Thirty-six young men were exposed for 2 hours to environmental temperatures of 10, 26.7, or 46C. Measurements of rectal and skin temperature, heart rate and respiratory rate were made, and average skin and average body temperatures were calculated. M...
Z. Sacharuk, Viviane; A. Lovatel, Gisele; Ilha, Jocemar; Marcuzzo, Simone; Severo do Pinho, Alexandre; L. Xavier, Léder; A. Zaro, Milton; Achaval, Matilde
2011-01-01
INTRODUCTION: Peripheral nerves are often damaged by direct mechanical injury, diseases, and tumors. The peripheral nerve injuries that result from these conditions can lead to a partial or complete loss of motor, sensory, and autonomic functions, which in turn are related to changes in skin temperature, in the involved segments of the body. The aim of this study was to evaluate the changes in hind paw skin temperature after sciatic nerve crush in rats in an attempt to determine whether changes in skin temperature correlate with the functional recovery of locomotion. METHODS: Wistar rats were divided into three groups: control (n = 7), sham (n = 25), and crush (n = 25). All groups were subjected to thermographic, functional, and histological assessments. RESULTS: ΔT in the crush group was different from the control and sham groups at the 1st, 3rd and 7rd postoperative days (p<0.05). The functional recovery from the crush group returned to normal values between the 3rd and 4th week post-injury, and morphological analysis of the nerve revealed incomplete regeneration at the 4th week after injury. DISCUSSION: This study is the first demonstration that sciatic nerve crush in rats induces an increase in hind paw skin temperature and that skin temperature changes do not correlate closely with functional recovery PMID:21876984
Dynamic Infrared Thermography Study of Blood Flow Relative to Lower Limp Position
NASA Astrophysics Data System (ADS)
Stathopoulos, I.; Skouroliakou, K.; Michail, C.; Valais, I.
2015-09-01
Thermography is an established method for studying skin temperature distribution. Temperature distribution on body surface is influenced by a variety of physiological mechanisms and has been proven a reliable indicator of various physiological disorders. Blood flow is an important factor that influences body heat diffusion and skin temperature. In an attempt to validate and further elucidate thermal models characterizing the human skin, dynamic thermography of the lower limp in horizontal and vertical position was performed, using a FLIR T460 thermographic camera. Temporal variation of temperature was recorded on five distinct points of the limp. Specific points were initially cooled by the means of an ice cube and measurements of the skin temperature were obtained every 30 seconds as the skin temperature was locally reduced and afterwards restored at its initial value. The return to thermal balance followed roughly the same pattern for all points of measurement, although the heating rate was faster when the foot was in horizontal position. Thermal balance was achieved faster at the spots that were positioned on a vein passage. Our results confirm the influence of blood flow on the thermal regulation of the skin. Spots located over veins exhibit different thermal behaviour due to thermal convection through blood flow. Changing the position of the foot from vertical to horizontal, effectively affects blood perfusion as in the vertical position blood circulation is opposed by gravity.
Prediction of facial cooling while walking in cold wind.
Tikuisis, Peter; Ducharme, Michel B; Brajkovic, Dragan
2007-09-01
A dynamic model of cheek cooling has been modified to account for increased skin blood circulation of individuals walking in cold wind. This was achieved by modelling the cold-induced vasodilation response to cold as a varying blood perfusion term, which provided a source of convective heat to the skin tissues of the model. Physiologically-valid blood perfusion was fitted to replicate the cheek skin temperature responses of 12 individuals experimentally exposed to air temperatures from -10 to 10 degrees C at wind speeds from 2 to 8 ms(-1). Resultant cheek skin temperatures met goodness-of-fit criteria and implications on wind chill predictions are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singha, Bandana; Solanki, Chetan Singh
Formation of boron skin is an unavoidable phenomenon in p-type emitter formation with boron dopant source. The boron skin thickness is generally less than 100 nm and difficult to remove by chemical and physical means. Low temperature oxidation (LTO) used in this work is useful in removing boron skin thickness up to 30 nm and improves the emitter performance. The effective minority carrier lifetime gets improved by more than 30% after using LTO and leakage current of the emitter gets lowered by 100 times thereby showing the importance of low temperature oxidation in boron spin on dopant diffused emitters.
Petrofsky, Jerrold Scott; Laymon, Michael; Berk, Lee; Bains, Gurinder
2016-03-01
The purpose of this study was to compare the effects of over-the-counter treatments-ThermaCare HeatWraps (chemical reaction to produce heat above the skin), Icy Hot Patch, and Icy Hot Cream (topically applied menthol)-on skin and deep tissue temperature. This was a longitudinal crossover study. On each of 3 days, a ThermaCare HeatWrap, Icy Hot Cream, or Icy Hot Patch was applied randomly over the quadriceps muscle in 15 healthy volunteers with normal body mass. Skin and muscle temperature and blood flow were measured by laser flowmetry every 15 minutes for 2 hours. After 2 hours, mean temperature decreased by 2.1°C (7.0%; P = .02) in skin and 1.0°C (2.9%; P = .01) in muscle with Icy Hot Cream. Icy Hot Patch decreased skin and muscle temperature by 1.7°C (5.4%; P = .03) and 1.3°C (3.8%; P = .01), respectively. In contrast, ThermaCare raised skin and muscle temperature by 7.8°C (25.8%; P = .001) and 2.7°C (7.7%; P = .002), respectively; both were significantly warmer with ThermaCare vs either Icy Hot product (all P < .007). Icy Hot products produced a net decrease in skin blood flow (Cream: 56.7 flux [39.3%; P = .003]; Patch: 19.1 flux [16.7%; P = .045]). Muscle blood flow decreased with the Patch (6.7 flux [7.0%; P = .02]). After a period of fluctuations, Icy Hot Cream produced a net increase vs baseline of 7.0 flux (16.9%; P = .02). ThermaCare more than doubled blood flow in skin (83.3 flux [109.7%; P = .0003]) and muscle (25.1 flux [148.5%; P = .004]). In this group of 15 healthy volunteers, ThermaCare HeatWraps provided the greatest degree of tissue warming and increase in tissue blood flow.
NASA Astrophysics Data System (ADS)
Priego Quesada, Jose Ignacio; Martínez Guillamón, Natividad; Cibrián Ortiz de Anda, Rosa M.a.; Psikuta, Agnes; Annaheim, Simon; Rossi, René Michel; Corberán Salvador, José Miguel; Pérez-Soriano, Pedro; Salvador Palmer, Rosario
2015-09-01
The aim of the present study was to compare infrared thermography and thermal contact sensors for measuring skin temperature during cycling in a moderate environment. Fourteen cyclists performed a 45-min cycling test at 50% of peak power output. Skin temperatures were simultaneously recorded by infrared thermography and thermal contact sensors before and immediately after cycling activity as well as after 10 min cooling-down, representing different skin wetness and blood perfusion states. Additionally, surface temperature during well controlled dry and wet heat exchange (avoiding thermoregulatory responses) using a hot plate system was assessed by infrared thermography and thermal contact sensors. In human trials, the inter-method correlation coefficient was high when measured before cycling (r = 0.92) whereas it was reduced immediately after the cycling (r = 0.82) and after the cooling-down phase (r = 0.59). Immediately after cycling, infrared thermography provided lower temperature values than thermal contact sensors whereas it presented higher temperatures after the cooling-down phase. Comparable results as in human trials were observed for hot plate tests in dry and wet states. Results support the application of infrared thermography for measuring skin temperature in exercise scenarios where perspiration does not form a water film.
Morita, Viviane de Souza; de Almeida, Vitor Rosa; Matos, João Batista; Vicentini, Tamiris Iara; van den Brand, Henry; Boleli, Isabel Cristina
2016-01-01
Skin and feather characteristics, which play a critical role in body temperature maintenance, can be affected by incubation circumstances, such as incubation temperature. However, no study to date has assessed the influence of incubation temperature during the fetal stage on morphometric characteristics and vascular development of the skin, feather characteristics, and their relationship to hormone levels and preferred temperature in later life in chickens. Broiler breeder eggs were exposed to low (36°C), control (37.5°C), or high (39°C) temperatures (treatments LT, CK, and HT, respectively) from day 13 of incubation onward, because it is known that the endocrine axes are already established at this time. During this period, eggshell temperature of HT eggs (38.8±0.33°C) was higher than of LT (37.4±0.08°C) and CK eggs (37.8 ±0.15°C). The difference between eggshell and incubator air temperature diminished with the increasing incubation temperature, and was approximately zero for HT. HT hatchlings had higher surface temperature on the head, neck, and back, and thinner and more vascularized skin than did CK and LT hatchlings. No differences were found among treatments for body weight, total feather weight, number and length of barbs, barbule length, and plasma T4 concentration. LT hatchlings showed lower plasma T3 and GH, as well as lower T3/T4 ratio and decreased vascularity in the neck, back, and thigh skin compared to CK hatchlings. On the other hand, HT hatchlings had decreased skin thickness and increased vascularity, and preferred a higher ambient temperature compared to CK and HT hatchlings. In addition, for all treatments, surface temperature on the head was higher than of the other body regions. We conclude that changes in skin thickness and vascularity, as well as changes in thyroid and growth hormone levels, are the result of embryonic strategies to cope with higher or lower than normal incubation temperatures. Additionally exposure to increased temperature during incubation is an environmental factor that can exert early-life influence on ambient temperature preference of broiler hatchlings in later life. PMID:27183111
Morita, Viviane de Souza; Almeida, Vitor Rosa de; Matos, João Batista; Vicentini, Tamiris Iara; van den Brand, Henry; Boleli, Isabel Cristina
2016-01-01
Skin and feather characteristics, which play a critical role in body temperature maintenance, can be affected by incubation circumstances, such as incubation temperature. However, no study to date has assessed the influence of incubation temperature during the fetal stage on morphometric characteristics and vascular development of the skin, feather characteristics, and their relationship to hormone levels and preferred temperature in later life in chickens. Broiler breeder eggs were exposed to low (36°C), control (37.5°C), or high (39°C) temperatures (treatments LT, CK, and HT, respectively) from day 13 of incubation onward, because it is known that the endocrine axes are already established at this time. During this period, eggshell temperature of HT eggs (38.8±0.33°C) was higher than of LT (37.4±0.08°C) and CK eggs (37.8 ±0.15°C). The difference between eggshell and incubator air temperature diminished with the increasing incubation temperature, and was approximately zero for HT. HT hatchlings had higher surface temperature on the head, neck, and back, and thinner and more vascularized skin than did CK and LT hatchlings. No differences were found among treatments for body weight, total feather weight, number and length of barbs, barbule length, and plasma T4 concentration. LT hatchlings showed lower plasma T3 and GH, as well as lower T3/T4 ratio and decreased vascularity in the neck, back, and thigh skin compared to CK hatchlings. On the other hand, HT hatchlings had decreased skin thickness and increased vascularity, and preferred a higher ambient temperature compared to CK and HT hatchlings. In addition, for all treatments, surface temperature on the head was higher than of the other body regions. We conclude that changes in skin thickness and vascularity, as well as changes in thyroid and growth hormone levels, are the result of embryonic strategies to cope with higher or lower than normal incubation temperatures. Additionally exposure to increased temperature during incubation is an environmental factor that can exert early-life influence on ambient temperature preference of broiler hatchlings in later life.
... tinged skin or pale skin Low body temperature (hypothermia) Passing out (unconsciousness) and can't be awakened ... level may drop low enough to cause seizures. Hypothermia. Your body temperature may drop so low that ...
Physiological and Psychological Evaluation of Strength of Auditory Stimulus
NASA Astrophysics Data System (ADS)
Umehara, Susumu; Asano, Hirotoshi; Ide, Hideto
In this study, we evaluated the pleasantness or unpleasantness experienced by human beings depending on the intensity of sound; using the nasal skin temperature that was determined using thermograms obtained from an infrared thermograph. Many studies have been carried out on the influence of sound intensity on human beings. However, the effect of sound has not been evaluated on the basis of facial skin temperature. We evaluated the experienced with variations in changes in the pleasure or displeasure noise; this was evaluated on the basis of facial skin temperature, electroencephalogram, and heart rate variability. The experimental results showed that the effect of variations in the sound intensity on the changes in the pleasure or displeasure experienced by human beings can be quantitatively evaluated on the basis of facial skin temperature.
NASA Technical Reports Server (NTRS)
Castro, Sandra L.; Emery, William J.
2002-01-01
The focus of this research was to determine whether the accuracy of satellite measurements of sea surface temperature (SST) could be improved by explicitly accounting for the complex temperature gradients at the surface of the ocean associated with the cool skin and diurnal warm layers. To achieve this goal, work centered on the development and deployment of low-cost infrared radiometers to enable the direct validation of satellite measurements of skin temperature. During this one year grant, design and construction of an improved infrared radiometer was completed and testing was initiated. In addition, development of an improved parametric model for the bulk-skin temperature difference was completed using data from the previous version of the radiometer. This model will comprise a key component of an improved procedure for estimating the bulk SST from satellites. The results comprised a significant portion of the Ph.D. thesis completed by one graduate student and they are currently being converted into a journal publication.
NASA Astrophysics Data System (ADS)
Adolph, Alden C.; Albert, Mary R.; Hall, Dorothy K.
2018-03-01
As rapid warming of the Arctic occurs, it is imperative that climate indicators such as temperature be monitored over large areas to understand and predict the effects of climate changes. Temperatures are traditionally tracked using in situ 2 m air temperatures and can also be assessed using remote sensing techniques. Remote sensing is especially valuable over the Greenland Ice Sheet, where few ground-based air temperature measurements exist. Because of the presence of surface-based temperature inversions in ice-covered areas, differences between 2 m air temperature and the temperature of the actual snow surface (referred to as skin
temperature) can be significant and are particularly relevant when considering validation and application of remote sensing temperature data. We present results from a field campaign extending from 8 June to 18 July 2015, near Summit Station in Greenland, to study surface temperature using the following measurements: skin temperature measured by an infrared (IR) sensor, 2 m air temperature measured by a National Oceanic and Atmospheric Administration (NOAA) meteorological station, and a Moderate Resolution Imaging Spectroradiometer (MODIS) surface temperature product. Our data indicate that 2 m air temperature is often significantly higher than snow skin temperature measured in situ, and this finding may account for apparent biases in previous studies of MODIS products that used 2 m air temperature for validation. This inversion is present during our study period when incoming solar radiation and wind speed are both low. As compared to our in situ IR skin temperature measurements, after additional cloud masking, the MOD/MYD11 Collection 6 surface temperature standard product has an RMSE of 1.0 °C and a mean bias of -0.4 °C, spanning a range of temperatures from -35 to -5 °C (RMSE = 1.6 °C and mean bias = -0.7 °C prior to cloud masking). For our study area and time series, MODIS surface temperature products agree with skin surface temperatures better than previous studies indicated, especially at temperatures below -20 °C, where other studies found a significant cold bias. We show that the apparent cold bias present in other comparisons of 2 m air temperature and MODIS surface temperature may be a result of the near-surface temperature inversion. Further investigation of how in situ IR skin temperatures compare to MODIS surface temperature at lower temperatures (below -35 °C) is warranted to determine whether a cold bias exists for those temperatures.
Distribution of skin temperature in Mexican children.
Kolosovas-Machuca, Eleazar Samuel; González, Francisco Javier
2011-08-01
Infrared thermography can be a valuable diagnostic tool in the evaluation and management of several pathologies; however, the temperature pattern of the healthy body should be known in order to perform a more precise clinical evaluation. A total of 25 healthy children (10 female and 15 male) were examined with a thermographic camera. Eighty-four temperature points of the body were recorded, saved in a database, and analyzed. The measurements showed that the forehead, neck, and the cervical area have the highest average temperatures of the whole body, and that the temperature distribution between boys and girls is very similar. The difference in skin temperature along the y-axis of the body varied up to 5.1°C; however, the average difference in skin temperature along the x-axis of the body was 0.7°C. These temperature variations observed in children are lower than the ones reported for adults, which could be due to a greater variation of body fat distribution in adults. This study shows that thermography could be a good tool for disease diagnosis in children as there is a lower skin temperature variation among children than among adults. © 2011 John Wiley & Sons A/S.
Erenberk, Ufuk; Torun, Emel; Ozkaya, Emin; Uzuner, Selcuk; Demir, Aysegul Dogan; Dundaroz, Rusen
2013-12-01
The aim of this study was to determine if the skin temperature of febrile children is affected by the child's exposure to cold outdoor temperatures immediately prior to the taking of that temperature. A total of 150 febrile and non-febrile children (aged 3-10 years) who had walked to the hospital's pediatric emergency department and were thus exposed to outside cold weather were enrolled in the study. Using infrared thermometry, forehead and chest skin temperatures were simultaneously measured every 2 min during the first 14 min after presentation. Temperatures were recorded and differences between the two measurements were calculated. By the fifth evaluation (10 min from the first reading), skin temperatures from forehead and chest had equalized. Determination of fever from the body parts that had been exposed to cold environmental conditions may cause contradictory results if taken while the child is still chilled from exposure to the cold. For accuracy, children should be acclimated to the indoor temperature before taking body temperature readings. Acclimation takes at least 10 min after coming in from cold weather outside. © 2013 The Authors. Pediatrics International © 2013 Japan Pediatric Society.
Azuma, Akifumi; Yakushiji, Hiroshi; Koshita, Yoshiko; Kobayashi, Shozo
2012-10-01
Temperature and light are important environmental factors that affect flavonoid biosynthesis in grape berry skin. However, the interrelationships between temperature and light effects on flavonoid biosynthesis have not been fully elucidated at the molecular level. Here, we investigated the effects of temperature and light conditions on the biosynthesis of flavonoids (anthocyanins and flavonols) and the expression levels of related genes in an in vitro environmental experiment using detached grape berries. Sufficient anthocyanin accumulation in the grape skin was observed under a low temperature (15 °C) plus light treatment, whereas high temperature (35 °C) or dark treatment severely suppressed anthocyanin accumulation. This indicates that the accumulation of anthocyanins is dependent on both low temperature and light. qRT-PCR analysis showed that the responses of three MYB-related genes (VlMYBA1-3, VlMYBA1-2, and VlMYBA2) to temperature and light differed greatly even though the products of all three genes had the ability to regulate anthocyanin biosynthesis pathway genes. Furthermore, the expression levels of other MYB-related genes and many flavonoid biosynthesis pathway genes were regulated independently by temperature and light. We also found that temperature and light conditions affected the anthocyanin composition in the skin through the regulation of flavonoid biosynthesis pathway genes. Our results suggest that low temperature and light have a synergistic effect on the expression of genes in the flavonoid biosynthesis pathway. These findings provide new information about the relationships between environmental factors and flavonoid accumulation in grape berry skin.
Gowrishankar, TR; Stewart, Donald A; Martin, Gregory T; Weaver, James C
2004-01-01
Background Investigation of bioheat transfer problems requires the evaluation of temporal and spatial distributions of temperature. This class of problems has been traditionally addressed using the Pennes bioheat equation. Transport of heat by conduction, and by temperature-dependent, spatially heterogeneous blood perfusion is modeled here using a transport lattice approach. Methods We represent heat transport processes by using a lattice that represents the Pennes bioheat equation in perfused tissues, and diffusion in nonperfused regions. The three layer skin model has a nonperfused viable epidermis, and deeper regions of dermis and subcutaneous tissue with perfusion that is constant or temperature-dependent. Two cases are considered: (1) surface contact heating and (2) spatially distributed heating. The model is relevant to the prediction of the transient and steady state temperature rise for different methods of power deposition within the skin. Accumulated thermal damage is estimated by using an Arrhenius type rate equation at locations where viable tissue temperature exceeds 42°C. Prediction of spatial temperature distributions is also illustrated with a two-dimensional model of skin created from a histological image. Results The transport lattice approach was validated by comparison with an analytical solution for a slab with homogeneous thermal properties and spatially distributed uniform sink held at constant temperatures at the ends. For typical transcutaneous blood gas sensing conditions the estimated damage is small, even with prolonged skin contact to a 45°C surface. Spatial heterogeneity in skin thermal properties leads to a non-uniform temperature distribution during a 10 GHz electromagnetic field exposure. A realistic two-dimensional model of the skin shows that tissue heterogeneity does not lead to a significant local temperature increase when heated by a hot wire tip. Conclusions The heat transport system model of the skin was solved by exploiting the mathematical analogy between local thermal models and local electrical (charge transport) models, thereby allowing robust, circuit simulation software to obtain solutions to Kirchhoff's laws for the system model. Transport lattices allow systematic introduction of realistic geometry and spatially heterogeneous heat transport mechanisms. Local representations for both simple, passive functions and more complex local models can be easily and intuitively included into the system model of a tissue. PMID:15548324
Kim, Siyeon; Lee, Joo-Young
2016-04-01
The aim of this study was to investigate stable and valid measurement sites of skin temperatures as a non-invasive variable to predict deep-body temperature while wearing firefighters' personal protective equipment (PPE) during air temperature changes. Eight male firefighters participated in an experiment which consisted of 60-min exercise and 10-min recovery while wearing PPE without self-contained breathing apparatus (7.75 kg in total PPE mass). Air temperature was periodically fluctuated from 29.5 to 35.5 °C with an amplitude of 6 °C. Rectal temperature was chosen as a deep-body temperature, and 12 skin temperatures were recorded. The results showed that the forehead and chest were identified as the most valid sites to predict rectal temperature (R(2) = 0.826 and 0.824, respectively) in an environment with periodically fluctuated air temperatures. This study suggests that particular skin temperatures are valid as a non-invasive variable when predicting rectal temperature of an individual wearing PPE in changing ambient temperatures. Practitioner Summary: This study should offer assistance for developing a more reliable indirect indicating system of individual heat strain for firefighters in real time, which can be used practically as a precaution of firefighters' heat-related illness and utilised along with physiological monitoring.
Turbine vane with high temperature capable skins
Morrison, Jay A [Oviedo, FL
2012-07-10
A turbine vane assembly includes an airfoil extending between an inner shroud and an outer shroud. The airfoil can include a substructure having an outer peripheral surface. At least a portion of the outer peripheral surface is covered by an external skin. The external skin can be made of a high temperature capable material, such as oxide dispersion strengthened alloys, intermetallic alloys, ceramic matrix composites or refractory alloys. The external skin can be formed, and the airfoil can be subsequently bi-cast around or onto the skin. The skin and the substructure can be attached by a plurality of attachment members extending between the skin and the substructure. The skin can be spaced from the outer peripheral surface of the substructure such that a cavity is formed therebetween. Coolant can be supplied to the cavity. Skins can also be applied to the gas path faces of the inner and outer shrouds.
The effect of using different regions of interest on local and mean skin temperature.
Maniar, Nirav; Bach, Aaron J E; Stewart, Ian B; Costello, Joseph T
2015-01-01
The dynamic nature of tissue temperature and the subcutaneous properties, such as blood flow, fatness, and metabolic rate, leads to variation in local skin temperature. Therefore, we investigated the effects of using multiple regions of interest when calculating weighted mean skin temperature from four local sites. Twenty-six healthy males completed a single trial in a thermonetural laboratory (mean ± SD): 24.0 (1.2)°C; 56 (8%) relative humidity; <0.1 m/s air speed). Mean skin temperature was calculated from four local sites (neck, scapula, hand and shin) in accordance with International Standards using digital infrared thermography. A 50 mm × 50 mm, defined by strips of aluminium tape, created six unique regions of interest, top left quadrant, top right quadrant, bottom left quadrant, bottom right quadrant, centre quadrant and the entire region of interest, at each of the local sites. The largest potential error in weighted mean skin temperature was calculated using a combination of a) the coolest and b) the warmest regions of interest at each of the local sites. Significant differences between the six regions interest were observed at the neck (P<0.01), scapula (P<0.001) and shin (P<0.05); but not at the hand (P = 0.482). The largest difference (± SEM) at each site was as follows: neck 0.2 (0.1)°C; scapula 0.2 (0.0)°C; shin 0.1 (0.0)°C and hand 0.1 (0.1)°C. The largest potential error (mean ± SD) in weighted mean skin temperature was 0.4 (0.1)°C (P<0.001) and the associated 95% limits of agreement for these differences was 0.2-0.5 °C. Although we observed differences in local and mean skin temperature based on the region of interest employed, these differences were minimal and are not considered physiologically meaningful. Copyright © 2015 Elsevier Ltd. All rights reserved.
Active and passive heat stress similarly compromise tolerance to a simulated hemorrhagic challenge.
Pearson, J; Lucas, R A I; Schlader, Z J; Zhao, J; Gagnon, D; Crandall, C G
2014-10-01
Passive heat stress increases core and skin temperatures and reduces tolerance to simulated hemorrhage (lower body negative pressure; LBNP). We tested whether exercise-induced heat stress reduces LBNP tolerance to a greater extent relative to passive heat stress, when skin and core temperatures are similar. Eight participants (6 males, 32 ± 7 yr, 176 ± 8 cm, 77.0 ± 9.8 kg) underwent LBNP to presyncope on three separate and randomized occasions: 1) passive heat stress, 2) exercise in a hot environment (40°C) where skin temperature was moderate (36°C, active 36), and 3) exercise in a hot environment (40°C) where skin temperature was matched relative to that achieved during passive heat stress (∼38°C, active 38). LBNP tolerance was quantified using the cumulative stress index (CSI). Before LBNP, increases in core temperature from baseline were not different between trials (1.18 ± 0.20°C; P > 0.05). Also before LBNP, mean skin temperature was similar between passive heat stress (38.2 ± 0.5°C) and active 38 (38.2 ± 0.8°C; P = 0.90) trials, whereas it was reduced in the active 36 trial (36.6 ± 0.5°C; P ≤ 0.05 compared with passive heat stress and active 38). LBNP tolerance was not different between passive heat stress and active 38 trials (383 ± 223 and 322 ± 178 CSI, respectively; P = 0.12), but both were similarly reduced relative to active 36 (516 ± 147 CSI, both P ≤ 0.05). LBNP tolerance is not different between heat stresses induced either passively or by exercise in a hot environment when skin temperatures are similarly elevated. However, LBNP tolerance is influenced by the magnitude of the elevation in skin temperature following exercise induced heat stress. Copyright © 2014 the American Physiological Society.
NASA Technical Reports Server (NTRS)
Chesters, D.
1984-01-01
An algorithm for calculating the atmospheric transmittance in the 10 to 20 micro m spectral band from a known temperature and dewpoint profile, and then using this transmittance to estimate the surface (skin) temperature from a VISSR observation in the 11 micro m window is presented. Parameterizations are drawn from the literature for computing the molecular absorption due to the water vapor continuum, water vapor lines, and carbon dioxide lines. The FORTRAN code is documented for this application, and the sensitivity of the derived skin temperature to variations in the model's parameters is calculated. The VISSR calibration uncertainties are identified as the largest potential source of error.
The effect of aging on conductive heat exchange in the skin at two environmental temperatures.
Petrofsky, Jerrold S; Lohman, Everett; Suh, Hye Jin; Garcia, Jason; Anders, Alexa; Sutterfield, Cassandra; Khandge, Chetan
2006-10-01
Ageing diminishes the blood flow (BF) response of the skin to autonomic stressors. While the diminished response of skin BF to global heating has been well documented, the effect of this reduction in skin BF on the ability of the skin to dissipate heat has not. When heat is added to the skin by the application of hot packs, if heat is not adequately removed, the skin can become dangerously hot and become damaged. The present investigation examined the heat dissipating properties of the skin in older individuals. This study has importance for the therapeutic application of hot packs which might cause burns easier in older people. In the present investigation, 10 younger and 10 older subjects were examined. The average age of the younger group was 25.9+/-3.4 years and the older group was 60 +/- 5.8 years. Heat was applied through a 49 gram brass probe that was heated to 41 degrees C and by a Peltier junction in a cool and warm environment. Skin required about 20 calories of heat to raise skin temperature 1 degrees C the cool room and double this Figure in the warm room. Ageing reduced the caloric requirement to increase skin temperature under both conditions (p < 0.01). The results of the experiments showed that older individuals had impaired ability of the skin to dissipate heat in both environments. Special precautions should be taken in physical therapy when applying hot packs in older populations.
2004-01-01
would be required to keep the animals relatively motionless in this position would likely exert undue emotional stress on the animals that could, in...34). The positive relationship of TEWL to skin temperature in psoriasis and eczema is different from that obtained in normal skin and can be...temperature in psoriasis and eczema . J Invest Dermatol 1975; 64(5):313-315. 36. Bircher AJ. Laser Doppler measurement of skin blood flux: variation and
A System Approach to Navy Medical Education and Training. Appendix 16. Aviation Technician.
1974-08-31
PHYSICAL/EMCTICNAL RESPONSE Tn ITREATMENT/DIAGNOSTIC PROCEDURES 5 IrSERVE/REPOPT SYMPTO4S OF SIDE EFFECTS TO TREATENT/MEOICATION 6 ICHECK TEXTURE OF...SKIN, E.G. DRY, OILY, SCALY 7 ICHECK COLOR OF SKIN, E.G. CYANOSIS, BLANCHING, JAUNPICE, MOTTLING 8 ICHECK TEMPERATURE OF SKIN j 9 IPERFORM...CIRCULATION CHECK, E.G. COLOR, PULSE, TEmPERATUrE OF ISKIN, CAPILLARY RETURN 10 ICHECK SKIN FOR ABNORMAL CONDITIONS, E.G. PPESSURE SORES, IBRUISES, NEEDLE MARKS
The effect of environmental humidity and temperature on skin barrier function and dermatitis.
Engebretsen, K A; Johansen, J D; Kezic, S; Linneberg, A; Thyssen, J P
2016-02-01
Physicians are aware that climatic conditions negatively affect the skin. In particular, people living in equator far countries such as the Northern parts of Europe and North America are exposed to harsh weather during the winter and may experience dry and itchy skin, or deterioration of already existing dermatoses. We searched the literature for studies that evaluated the mechanisms behind this phenomenon. Commonly used meteorological terms such as absolute humidity, relative humidity and dew point are explained. Furthermore, we review the negative effect of low humidity, low temperatures and different seasons on the skin barrier and on the risk of dermatitis. We conclude that low humidity and low temperatures lead to a general decrease in skin barrier function and increased susceptible towards mechanical stress. Since pro-inflammatory cytokines and cortisol are released by keratinocytes, and the number of dermal mast cells increases, the skin also becomes more reactive towards skin irritants and allergens. Collectively, published data show that cold and dry weather increase the prevalence and risk of flares in patients with atopic dermatitis. © 2015 European Academy of Dermatology and Venereology.
Brajkovic, Dragan; Ducharme, Michel B
2005-07-01
This study evaluated a zero-heat-flow (ZHF), non-invasive temperature probe for in- vivo measurement of resting muscle temperature for up to 2 cm below the skin surface. The ZHF probe works by preventing heat loss from the tissue below the probe by actively heating the tissue until no temperature gradient exists across the probe. The skin temperature under the probe is then used as an indicator of the muscle temperature below. Eight subjects sat for 130 min during exposure to 28 degrees C air. Vastus lateralis (lateral thigh) muscle temperature was measured non-invasively using a ZHF probe which covered an invasive multicouple probe (which measured tissue temperature 0.5 cm, 1 cm, 1.5 cm, and 2 cm below the skin) located 15 cm superior to the patella (T (covered)). T (covered) was evaluated against an uncovered control multicouple probe located 20 cm superior to the patella (T (uncovered)). Rectal temperature and lateral thigh skin temperature were also measured. Mean T (uncovered) (based on average temperatures at the 0.5 cm, 1 cm, 1.5 cm, and 2 cm depths) and Mean T (covered) were similar from time 0 min to 60 min. However, when the ZHF was turned on at 70 min, Mean T (covered) increased by 2.11 +/- 0.20 degrees C by 130 min, while T (uncovered) remained stable. The ZHF probe temperature was similar to T (covered) at 1 cm and after time 85 min, significantly higher than T (covered) at the 0.5 cm, 1.5 cm, and 2 cm depths; however from a physiological standpoint, the temperatures between the different depths and the ZHF probe could be considered uniform (< or =0.2 degrees C separation). Rectal and thigh skin temperatures were stable at 36.99 +/- 0.08 degrees C and 32.82 +/- 0.23 degrees C, respectively. In conclusion, the non-invasive ZHF probe temperature was similar to the T (covered) temperatures directly measured up to 2 cm beneath the surface of the thigh, but all T (covered) temperatures were not representative of the true muscle temperature up to 2 cm below the skin because the ZHF probe heated the muscle by 2.11 +/- 0.20 degrees C during its operation.
NASA Technical Reports Server (NTRS)
Quinn, R. D.; Gong, L.
1978-01-01
Skin temperatures, shearing forces, surface static pressures, and boundary layer pitot pressures and total temperatures were measured on a hollow cylinder 3.04 meters long and 0.437 meter in diameter mounted beneath the fuselage of the YF-12A airplane. The data were obtained at a nominal free stream Mach number of 3.0 and at wall-to-recovery temperature ratios of 0.66 to 0.91. The free stream Reynolds number had a minimal value of 4.2 million per meter. Heat transfer coefficients and skin friction coefficients were derived from skin temperature time histories and shear force measurements, respectively. Boundary layer velocity profiles were derived from pitot pressure measurements, and a Reynolds analogy factor of 1.11 was obtained from the measured heat transfer and skin friction data. The skin friction coefficients predicted by the theory of van Driest were in excellent agreement with the measurements. Theoretical heat transfer coefficients, in the form of Stanton numbers calculated by using a modified Reynolds analogy between skin friction and heat transfer, were compared with measured values. The measured velocity profiles were compared to Coles' incompressible law-of-the-wall profile.
Surface Emissivity Effects on Thermodynamic Retrieval of IR Spectral Radiance
NASA Technical Reports Server (NTRS)
Zhou, Daniel K.; Larar, Allen M.; Smith, William L.; Liu, Xu
2006-01-01
The surface emissivity effect on the thermodynamic parameters (e.g., the surface skin temperature, atmospheric temperature, and moisture) retrieved from satellite infrared (IR) spectral radiance is studied. Simulation analysis demonstrates that surface emissivity plays an important role in retrieval of surface skin temperature and terrestrial boundary layer (TBL) moisture. NAST-I ultraspectral data collected during the CLAMS field campaign are used to retrieve thermodynamic properties of the atmosphere and surface. The retrievals are then validated by coincident in-situ measurements, such as sea surface temperature, radiosonde temperature and moisture profiles. Retrieved surface emissivity is also validated by that computed from the observed radiance and calculated emissions based on the retrievals of surface temperature and atmospheric profiles. In addition, retrieved surface skin temperature and emissivity are validated together by radiance comparison between the observation and retrieval-based calculation in the window region where atmospheric contribution is minimized. Both simulation and validation results have lead to the conclusion that variable surface emissivity in the inversion process is needed to obtain accurate retrievals from satellite IR spectral radiance measurements. Retrieval examples are presented to reveal that surface emissivity plays a significant role in retrieving accurate surface skin temperature and TBL thermodynamic parameters.
The Effect of Cushion Properties on Skin Temperature and Humidity at the Body-Support Interface.
Hsu, Tzu-Wen; Yang, Shu-Yu; Liu, Jung-Tai; Pan, Cheng-Tang; Yang, Yu-Sheng
2016-09-29
To explore the effects of various cushions on skin temperature and moisture at the body-seat interface during a 2-h period of continuous sitting. Seventy-eight participants were randomly assigned to sit on one of the three types of wheelchair cushion for unrelieved sitting over 2 h. Skin temperature and relative humidity (RH) were measured under the subjects' ischial tuberosities and thighs bilaterally with digital temperature and humidity sensors. Data were collected before sitting and at 15-min intervals thereafter. Participants sitting on foam-fluid hybrid cushions showed significantly lower skin temperatures than those sitting on air-filled and foam cushions (p < 0.05), but RH did not differ significantly among the cushions (p = 0.97). The three cushions produced a similar increasing trend in RH over time and RH reached a plateau during the 2-h sitting period. In order to select the appropriate wheelchair cushion, the microclimate (heat and moisture control) between the body-seat interface should be considered as well as pressure distribution. In comparison with foam-fluid hybrid cushions, the air-filled rubber and foam cushions tended to increase skin temperature by several degrees after prolonged sitting. However, cushion materials did not have significant differences in moisture accumulations.
The effect of cushion properties on skin temperature and humidity at the body-support interface.
Hsu, Tzu-Wen; Yang, Shu-Yu; Liu, Jung-Tai; Pan, Cheng-Tang; Yang, Yu-Sheng
2016-09-29
The purpose of this study is to explore the effects of various cushions on skin temperature and moisture at the body-seat interface during a 2-hour period of continuous sitting. Seventy-eight participants were randomly assigned to sit on one of the three types of wheelchair cushions for unrelieved sitting for over 2 hours. Skin temperature and relative humidity (RH) were measured under the subjects' ischial tuberosities and thighs bilaterally with digital temperature and humidity sensors. Data were collected before sitting and at 15-minute intervals thereafter. Participants sitting on foam-fluid hybrid cushions showed significantly lower skin temperatures than those sitting on air-filled and foam cushions (p < 0.05), but RH did not differ significantly among the cushions (p = 0.97). The three cushions produced a similar increasing trend in RH over time and RH reached a plateau during the 2-hour sitting period. To select the appropriate wheelchair cushion, the microclimate (heat and moisture control) between the body-seat interface should be considered as well as pressure distribution. In comparison with foam-fluid hybrid cushions, the air-filled rubber and foam cushions tended to increase skin temperature by several degrees after prolonged sitting. However, cushion materials did not have significant differences in moisture accumulations.
NASA Astrophysics Data System (ADS)
Alappattu, Denny P.; Wang, Qing; Yamaguchi, Ryan; Lind, Richard J.; Reynolds, Mike; Christman, Adam J.
2017-08-01
The sea surface temperature (SST) relevant to air-sea interaction studies is the temperature immediately adjacent to the air, referred to as skin SST. Generally, SST measurements from ships and buoys are taken at depths varies from several centimeters to 5 m below the surface. These measurements, known as bulk SST, can differ from skin SST up to O(1°C). Shipboard bulk and skin SST measurements were made during the Coupled Air-Sea Processes and Electromagnetic ducting Research east coast field campaign (CASPER-East). An Infrared SST Autonomous Radiometer (ISAR) recorded skin SST, while R/V Sharp's Surface Mapping System (SMS) provided bulk SST from 1 m water depth. Since the ISAR is sensitive to sea spray and rain, missing skin SST data occurred in these conditions. However, SMS measurement is less affected by adverse weather and provided continuous bulk SST measurements. It is desirable to correct the bulk SST to obtain a good representation of the skin SST, which is the objective of this research. Bulk-skin SST difference has been examined with respect to meteorological factors associated with cool skin and diurnal warm layers. Strong influences of wind speed, diurnal effects, and net longwave radiation flux on temperature difference are noticed. A three-step scheme is established to correct for wind effect, diurnal variability, and then for dependency on net longwave radiation flux. Scheme is tested and compared to existing correction schemes. This method is able to effectively compensate for multiple factors acting to modify bulk SST measurements over the range of conditions experienced during CASPER-East.
Simhon, David; Halpern, Marisa; Brosh, Tamar; Vasilyev, Tamar; Ravid, Avi; Tennenbaum, Tamar; Nevo, Zvi; Katzir, Abraham
2007-02-01
A feedback temperature-controlled laser soldering system (TCLS) was used for bonding skin incisions on the backs of pigs. The study was aimed: 1) to characterize the optimal soldering parameters, and 2) to compare the immediate and long-term wound healing outcomes with other wound closure modalities. A TCLS was used to bond the approximated wound margins of skin incisions on porcine backs. The reparative outcomes were evaluated macroscopically, microscopically, and immunohistochemically. The optimal soldering temperature was found to be 65 degrees C and the operating time was significantly shorter than with suturing. The immediate tight sealing of the wound by the TCLS contributed to rapid, high quality wound healing in comparison to Dermabond or Histoacryl cyanoacrylate glues or standard suturing. TCLS of incisions in porcine skin has numerous advantages, including rapid procedure and high quality reparative outcomes, over the common standard wound closure procedures. Further studies with a variety of skin lesions are needed before advocating this technique for clinical use.
Vos, Pieter; De Cock, Paul; Munde, Vera; Petry, Katja; Van Den Noortgate, Wim; Maes, Bea
2012-01-01
Identifying emotions in people with severe and profound intellectual disabilities is a difficult challenge. Since self-reports are not available, behaviour is the most used source of information. Given the limitations and caveats associated with using behaviour as the sole source of information about their emotions, it is important to supplement behavioural information with information from another source. As it is accepted that emotions consist of language, behaviour and physiology, in this article we investigated if physiology could give information about the emotions of people with severe and profound intellectual disabilities. To this aim we tested hypotheses derived from the motivational model of Bradley, Codispoti, Cuthbert, and Lang (2001) about the relation between heart rate and the valence of emotions and between heart rate, skin conductance and skin temperature and behavioural expressions of emotions of people with severe and profound intellectual disability. We presented 27 participants with 4 staff-selected negative and 4 staff-selected positive stimuli. The situations were videotaped and their heart rate, skin conductance and skin temperature was measured. Each behaviour of the participant was coded using the observational method developed by Petry and Maes (2006). As hypothesized, we found a lower heart rate when participants were presented with negative stimuli than when they were presented with positive stimuli in the first 6s of stimuli presentation. Their skin temperature was higher for the expression of low intensity negative emotions compared to the expression of low intensity positive emotions. The results suggest that, as with people without disability, heart rate and skin temperature can give information about the emotions of persons with severe and profound ID. Copyright © 2012 Elsevier Ltd. All rights reserved.
Oztas, Zafer; Barut Selver, Ozlem; Akkin, Cezmi; Canturk, Ecem; Afrashi, Filiz
2016-05-01
In our study, we aimed to investigate the correlation of handheld infrared skin thermometer and videothermography device for the measurement of corneal temperature. Forty healthy individuals (80 eyes) were enrolled to the study. Participants underwent a detailed ophthalmologic examination and medical history review for excluding any ocular and systemic diseases. The measurements of the central corneal temperature were performed in a room having constant temperature, humidity, and brightness levels. To avoid any variability, all the temperature measurements were performed in the same examination room by a single examiner. The temperature was measured with a handheld infrared skin thermometer (MEDISANA, FTN) from the corneal surface. The same instrument was also used to measure the subjects' body temperature. Moreover, the subjects underwent the corneal temperature measurement by a noncontact videothermography device (Optris PI 450; Optris GmbH). The male to female ratio was 19:21 among the subjects. The mean age was 25.1±4.7 years. The mean body temperature was 36.93±0.33°C. The mean corneal temperatures measured by the handheld infrared skin thermometer and the ocular videothermography device were 36.94±0.28°C and 35.61±0.61°C, respectively (P<0.01). The mean temperature difference was 1.34±0.57°C, with a 95% confidence interval. There was a moderate correlation between the corneal temperatures measured by the 2 devices in the right, the left eyes, and both eyes, respectively (P=0.450, 0.539, 0.490). Handheld infrared skin thermometers can be used for the evaluation of the corneal temperature. These devices may provide a simple, practical, and cheaper way to detect the corneal temperature, and the widely performed corneal temperature measurements may afford us to understand the temperature variability in numerous ocular conditions in a better way.
Design of a detection system of highlight LED arrays' effect on the human organization
NASA Astrophysics Data System (ADS)
Chen, Shuwang; Shi, Guiju; Xue, Tongze; Liu, Yanming
2009-05-01
LED (Light Emitting Diode) has many advantages in the intensity, wavelength, practicality and price, so it is feasible to apply in biomedicine engineering. A system for the research on the effect of highlight LED arrays to human organization is designed. The temperature of skin surface can rise if skin and organization are in irradiation by highlight LED arrays. The metabolism and blood circulation of corresponding position will be quicker than those not in the shine, so the surface temperature will vary in different position of skin. The structure of LED source arrays system is presented and a measure system for studying LED's influence on human organization is designed. The temperature values of shining point are detected by infrared temperature detector. Temperature change is different according to LED parameters, such as the number, irradiation time and luminous intensity of LED. Experimental device is designed as an LED arrays pen. The LED arrays device is used to shine the points of human body, then it may effect on personal organization as well as the acupuncture. The system is applied in curing a certain skin disease, such as age pigment, skin cancer and fleck.
1994-05-01
TskY=250K) ... 5-27 6-1. Treeline Correlation With 10.1 Microns ...................... 6-2 6-2. Mean Contrast: CARC Panel vs. Treeline ...6-3 6-3. CARC Panel and Treeline .............................. 6-5 6-4. Signal-to-Clutter Ratio for CARC Panel vs. Treeline ............. 6-6 6...5. Low Emissivity Panel and Treeline ......................... 6-7 xii TABLES 4-1: Sensor Characterization Test Summary ....................... 4-2 4
NASA Astrophysics Data System (ADS)
Kubota, Kouhei; Nuruki, Atsuo; Tamari, Youzou; Yunokuchi, Kazutomo
Recently, the stiff shoulder accompanying the muscle fatigue becomes an issue of public concern. Therefore, we paid attention to the effect of the thermal and magnetic stimulation for the muscle fatigue. The maximum voluntary contraction has recovered significantly, and also peripheral blood flow has increased by stimulation. In order to evaluate if the thermal and magnetic stimulation has any effects, three parameters was measured, which are the maximum voluntary contraction, peripheral blood flow and skin temperature. The skin temperature, however, did not changed significantly.
Alekseev, S I; Ziskin, M S; Fesenko, E E
2011-01-01
The possibility of using thermocouples for the artifact-free measurements of skin temperature during millimeter wave exposure was studied. The distributions of the specific absorption rate (SAR) in the human skin were calculated for different orientations of the thermocouple relative to the E-field of exposure. It was shown that, at the parallel orientation of a thermocouple relative to the E-field, SAR significantly increased at the tip of the thermocouple. This can result in an overheating of the thermocouple. At the perpendicular orientation of a thermocouple, the distortions of the SAR were insignificant. The data obtained confirm that the skin temperature can be measured with a thermocouple during exposure under the condition that the thermocouple is located perpendicular to the E-vector of the electromagnetic field. For the accurate determination of SAR from the rate of the initial temperature rise, it is necessary to fit the temperature kinetics measured with the thermocouple to the solution of the bio-heat transfer equation.
Thermal responses and perceptions under distinct ambient temperature and wind conditions.
Shimazaki, Yasuhiro; Yoshida, Atsumasa; Yamamoto, Takanori
2015-01-01
Wind conditions are widely recognized to influence the thermal states of humans. In this study, we investigated the relationship between wind conditions and thermal perception and energy balance in humans. The study participants were exposed for 20 min to 3 distinct ambient temperatures, wind speeds, and wind angles. During the exposure, the skin temperatures as a physiological reaction and mental reactions of the human body were measured and the energy balance was calculated based on the human thermal-load method. The results indicate that the human thermal load is an accurate indicator of human thermal states under all wind conditions. Furthermore, wind speed and direction by themselves do not account for the human thermal experience. Because of the thermoregulation that occurs to prevent heat loss and protect the core of the body, a low skin temperature was maintained and regional differences in skin temperature were detected under cool ambient conditions. Thus, the human thermal load, which represents physiological parameters such as skin-temperature change, adequately describes the mixed sensation of the human thermal experience. Copyright © 2015 Elsevier Ltd. All rights reserved.
Variation in rhinarium temperature indicates sensory specializations in placental mammals.
Gläser, Nele; Kröger, Ronald H H
2017-07-01
The rhinarium, a specialized nose-tip characterized by an area of naked and wet skin around the nostrils, is a typical mammalian structure. The type and amount of innervation suggests a sensory role and morphological diversity implies so far unidentified species-specific functional specializations. Rhinaria also vary in temperature and this may be related to the functions of these sensory organs. We performed a comparative study on rhinarium temperature in order to learn more about possible correlations with phylogeny and ecology. We have concentrated on terrestrial carnivorans and large herbivores, but also investigated a number of other species, some of them lacking typical rhinaria. We used infrared (IR) thermography to determine nose skin temperatures from safe distances and without interfering with the animals' behavior. In all groups studied, the temperature of the rhinarium/nose-tip decreased with decreasing ambient temperature. At all ambient temperatures, rhinarium temperature was lower, by 9-17°C, in carnivorans compared to herbivores. Glires (rodents and lagomorphs), haplorrhine primates, and omnivorous Perisso- and Artiodactyla were intermediate. In strepsirrhine primates, rhinarium temperature was similar to ambient temperature. Our findings in Strepsirrhini are consistent with the hypothesis that their rhinaria have an indirect role in chemical communication. Warm rhinaria in herbivores suggest a tactile function, while the low skin temperatures on carnivoran rhinaria may make the skin particularly sensitive to warming. Copyright © 2017 Elsevier Ltd. All rights reserved.
Khalil, Omar S; Yeh, Shu-Jen; Lowery, Michael G; Wu, Xiaomao; Hanna, Charles F; Kantor, Stanislaw; Jeng, Tzyy-Wen; Kanger, Johannes S; Bolt, Rene A; de Mul, Frits F
2003-04-01
We determine temperature effect on the absorption and reduced scattering coefficients (mu(a) and mu(s)(')) of human forearm skin. Optical and thermal simulation data suggest that mu( a) and mu(s)(') are determined within a temperature-controlled depth of approximately 2 mm. Cutaneous mu(s)(') change linearly with temperature. Change in mu(a) was complex and irreversible above body normal temperatures. Light penetration depth (delta) in skin increased on cooling, with considerable person-to-person variations. We attribute the effect of temperature on mu(s)(') to change in refractive index mismatch, and its effect on mu(a) to perfusion changes. The reversible temperature effect on mu (s)(' ) was maintained during more than 90 min. contact between skin and the measuring probe, where temperature was modulated between 38 and 22 degrees C for multiple cycles While temperature modulated mu(s)(' ) instantaneously and reversibly, mu(a) exhibited slower response time and consistent drift. There was a statistically significant upward drift in mu(a) and a mostly downward drift in mu( s)(') over the contact period. The drift in temperature-induced fractional change in mu(s)(') was less statistically significant than the drift in mu(s)('). Deltamu( s)(') values determined under temperature modulation conditions may have less nonspecific drift than mu(s)(') which may have significance for noninvasive determination of analytes in human tissue.
Histamine response and local cooling in the human skin: involvement of H1- and H2-receptors.
Grossmann, M; Jamieson, M J; Kirch, W
1999-08-01
Histamine may contribute locally to cutaneous blood flow control under normal and pathologic conditions. The objective of this study was to observe the influence of skin temperature on histamine vasodilation, and the roles of H1-and H2-receptors using novel noninvasive methods. Eleven healthy subjects received, double-blind, single doses of the H1-receptor antagonist cetirizine (10 mg), cetirizine (10 mg) plus the H2-receptor antagonist cimetidine (400 mg), or placebo on separate occasions. Histamine was dosed cumulatively by iontophoresis to the forearm skin at 34 degrees C and 14 degrees C. Laser-Doppler flux (LDF) was measured at the same sites using customised probeholder/iontophoretic chambers with Peltier cooling elements. Finger mean arterial pressure (MAP) was measured and cutaneous vascular conductance calculated as LDF/MAP. Histamine vasodilation was reduced in cold skin. Cetirizine shifted the histamine dose-response at both temperatures: statistically significantly at 14 degrees C only. Combined H1- and H2-receptor antagonism shifted the response significantly at both temperatures. H1- and H2-receptors mediate histamine-induced skin vasodilation. The sensitivity of these receptors, particularly the H1- receptor, is attenuated at low skin temperature. Whether the reduced effect in cold skin represents specific receptor or postreceptor desensitization, or nonspecific attenuation of cutaneous vasodilation remains to be elucidated.
Padula, Cristina; Pescina, Silvia; Nicoli, Sara; Santi, Patrizia
2018-02-15
The aim of this work was to characterize in vitro and ex vivo the performances of Durogesic and of two bioequivalent generic products, by evaluating: (a) fentanyl release; (b) fentanyl permeation across porcine skin and (c) fentanyl ease of extraction. Additional characteristics studied are the effect of temperature and skin integrity, applied individually or combined, to check a possible synergism. The two generic patches resulted equivalent to the originator according to the new Guideline. Nevertheless, the same data reported in a different way, i.e. considering the total amount of drug permeated from the whole patch over the application time, highlight differences among the patches. The additional tests performed showed that skin integrity does not represent a barrier for fentanyl permeation across the skin, regardless of the type and complexity of the patch. The effect of temperature resulted critical for two out of three patches, probably due to the different composition and to the different structure. The combination of skin damage and elevated temperature did not produce a synergistic effect. Fentanyl extraction was different for the different products and variable according to the conditions used. The results reported in the present work underline the influence of patch composition and complexity on fentanyl extraction, release and skin permeation, in particular in conditions that can be critical, such as elevated temperature. In particular, the effect of critical variables, such as skin integrity and temperature, should be addressed to in the development of a new or new generic patch and new discriminant tests should be developed. Copyright © 2017 Elsevier B.V. All rights reserved.
Kudo, Yukiko; Sasaki, Makiko; Kikuchi, Yukiko; Sugiyama, Reiko; Hasebe, Makiko; Ishii, Noriko
2018-06-19
The present study was conducted in order to clarify the effects of a warm hand bath at 40°C for 10 min on the blood flow in the shoulder, skin and deep body temperature, autonomic nervous activity, and subjective comfort in healthy women. The study's participants were 40 healthy adult women who were randomly assigned to either a structured hand bath first and no hand bath second (Group A) or to no hand bath first and a hand bath second (Group B). The blood flow in the shoulder, skin and deep body temperature, autonomic nervous activity, and subjective comfort then were recorded in all the participants. A repeated-measures ANOVA revealed no significant difference in the blood flow in the right shoulder or deep body temperature between groups. The skin temperature of the hands, forearms, and arms was significantly increased, but not of the face and upper back. The skin temperature of the forearms was maintained at 0.5°C-1°C higher for 30 min in the hand bath group, compared with the no hand bath group. The hand bath group had a significantly higher heart rate while bathing and a significantly lower parasympathetic nerve activity level during bathing. No significant difference was seen in the sympathetic activity level between groups. The hand bath group had a significantly higher subjective comfort level. Hand baths can improve the level of subjective comfort and increase the heart rate and might affect autonomic nervous activity. The skin temperature of the forearms was maintained for 30 min in the hand bath group. © 2018 Japan Academy of Nursing Science.
Muscle, skin and core temperature after -110°c cold air and 8°c water treatment.
Costello, Joseph Thomas; Culligan, Kevin; Selfe, James; Donnelly, Alan Edward
2012-01-01
The aim of this investigation was to elucidate the reductions in muscle, skin and core temperature following exposure to -110°C whole body cryotherapy (WBC), and compare these to 8°C cold water immersion (CWI). Twenty active male subjects were randomly assigned to a 4-min exposure of WBC or CWI. A minimum of 7 days later subjects were exposed to the other treatment. Muscle temperature in the right vastus lateralis (n=10); thigh skin (average, maximum and minimum) and rectal temperature (n=10) were recorded before and 60 min after treatment. The greatest reduction (P<0.05) in muscle (mean ± SD; 1 cm: WBC, 1.6 ± 1.2°C; CWI, 2.0 ± 1.0°C; 2 cm: WBC, 1.2 ± 0.7°C; CWI, 1.7 ± 0.9°C; 3 cm: WBC, 1.6 ± 0.6°C; CWI, 1.7 ± 0.5°C) and rectal temperature (WBC, 0.3 ± 0.2°C; CWI, 0.4 ± 0.2°C) were observed 60 min after treatment. The largest reductions in average (WBC, 12.1 ± 1.0°C; CWI, 8.4 ± 0.7°C), minimum (WBC, 13.2 ± 1.4°C; CWI, 8.7 ± 0.7°C) and maximum (WBC, 8.8 ± 2.0°C; CWI, 7.2 ± 1.9°C) skin temperature occurred immediately after both CWI and WBC (P<0.05). Skin temperature was significantly lower (P<0.05) immediately after WBC compared to CWI. The present study demonstrates that a single WBC exposure decreases muscle and core temperature to a similar level of those experienced after CWI. Although both treatments significantly reduced skin temperature, WBC elicited a greater decrease compared to CWI. These data may provide information to clinicians and researchers attempting to optimise WBC and CWI protocols in a clinical or sporting setting.
ATR-IR study of skin components: Lipids, proteins and water. Part I: Temperature effect
NASA Astrophysics Data System (ADS)
Olsztyńska-Janus, S.; Pietruszka, A.; Kiełbowicz, Z.; Czarnecki, M. A.
2018-01-01
In this work we report the studies of the effect of temperature on skin components, such as lipids, proteins and water. Modifications of lipids structure induced by increasing temperature (from 20 to 90 °C) have been studied using ATR-IR (Attenuated Total Reflectance Infrared) spectroscopy, which is a powerful tool for characterization of the molecular structure and properties of tissues, such as skin. Due to the small depth of penetration (0.6-5.6 μm), ATR-IR spectroscopy probes only the outermost layer of the skin, i.e. the stratum corneum (SC). The assignment of main spectral features of skin components allows for the determination of phase transitions from the temperature dependencies of band intensities [e.g. νas(CH2) and νs(CH2)]. The phase transitions were determined by using two methods: the first one was based on the first derivative of the Boltzmann function and the second one employed tangent lines of sigmoidal, aforementioned dependencies. The phase transitions in lipids were correlated with modifications of the structure of water and proteins.
Al-Armaghany, Allann; Tong, Kenneth; Highton, David; Leung, Terence S
2016-01-01
We have previously developed a hybrid microwave-optical system to monitor microvascular changes in response to thermal provocation in muscle. The hybrid probe is capable of inducing deep heat from the skin surface using mild microwaves (1-3 W) and raises the tissue temperature by a few degrees Celsius. This causes vasodilation and the subsequent increase in blood volume is detected by the hybrid probe using near infrared spectroscopy. The hybrid probe is also equipped with a skin cooling system which lowers the skin temperature while allowing microwaves to warm up deeper tissues. The hybrid system can be used to assess the condition of the vasculature in response to thermal stimulation. In this validation study, thermal imaging has been used to assess the temperature distribution on the surface of phantoms and human calf, following microwave warming. The results show that the hybrid system is capable of changing the skin temperature with a combination of microwave warming and skin cooling. It can also detect thermal responses in terms of changes of oxy/deoxy-hemoglobin concentrations.
Majewski, Sebastian; Pietrzak, Anna; Tworek, Damian; Szewczyk, Karolina; Kumor-Kisielewska, Anna; Kurmanowska, Zofia; Górski, Paweł; Zalewska-Janowska, Anna; Piotrowski, Wojciech Jerzy
2017-01-01
The systemic (extrapulmonary) effects and comorbidities of chronic obstructive pulmonary disease (COPD) contribute substantially to its burden. The supposed link between COPD and its systemic effects on distal organs could be due to the low-grade systemic inflammation. The aim of this study was to investigate whether the systemic inflammation may influence the skin condition in COPD patients. Forty patients with confirmed diagnosis of COPD and a control group consisting of 30 healthy smokers and 20 healthy never-smokers were studied. Transepidermal water loss, stratum corneum hydration, skin sebum content, melanin index, erythema index, and skin temperature were measured with worldwide-acknowledged biophysical measuring methods at the volar forearm of all participants using a multifunctional skin physiology monitor. Biomarkers of systemic inflammation, including high-sensitivity C-reactive protein (hsCRP), interleukin-6 (IL-6), and tumor necrosis factor α (TNF-α), were measured in serum using commercially available enzyme-linked immunosorbent assays. There were significant differences between COPD patients and healthy never-smokers in skin temperature, melanin index, sebum content, and hydration level ( P <0.05), but not for transepidermal water loss and erythema index. No significant difference was noted between COPD patients and smokers in any of the biophysical properties of the skin measured. The mean levels of hsCRP and IL-6 in serum were significantly higher in COPD patients and healthy smokers in comparison with healthy never-smokers. There were significant correlations between skin temperature and serum hsCRP ( R =0.40; P =0.02) as well as skin temperature and serum IL-6 ( R =0.49; P =0.005) in smokers. Stratum corneum hydration correlated significantly with serum TNF-α ( R =0.37; P =0.01) in COPD patients. Differences noted in several skin biophysical properties and biomarkers of systemic inflammation between COPD patients, smokers, and healthy never-smokers may suggest a possible link between smoking-driven, low-grade systemic inflammation, and the overall skin condition.
Madden, Victoria J; Catley, Mark J; Grabherr, Luzia; Mazzola, Francesca; Shohag, Mohammad; Moseley, G Lorimer
2016-01-01
Background. Nd:YAP laser is widely used to investigate the nociceptive and pain systems, generating perpetual and laser-evoked neurophysiological responses. A major procedural concern for the use of Nd:YAP laser stimuli in experimental research is the risk of skin damage. The absorption of Nd:YAP laser stimuli is greater in darker skin, or in pale skin that has been darkened with ink, prompting some ethics boards to refuse approval to experimenters wishing to track stimulus location by marking the skin with ink. Some research questions, however, require laser stimuli to be delivered at particular locations or within particular zones, a requirement that is very difficult to achieve if marking the skin is not possible. We thoroughly searched the literature for experimental evidence and protocol recommendations for safe delivery of Nd:YAP laser stimuli over marked skin, but found nothing. Methods. We designed an experimental protocol to define safe parameters for the use of Nd:YAP laser stimuli over skin that has been marked with black dots, and used thermal imaging to assess the safety of the procedure at the forearm and the back. Results. Using thermal imaging and repeated laser stimulation to ink-marked skin, we demonstrated that skin temperature did not increase progressively across the course of the experiment, and that the small change in temperature seen at the forearm was reversed during the rest periods between blocks. Furthermore, no participant experienced skin damage due to the procedure. Conclusion. This protocol offers parameters for safe, confident and effective experimentation using repeated Nd:YAP laser on skin marked with ink, thus paving the way for investigations that depend on it.
Temperament affects sympathetic nervous function in a normal population.
Kim, Bora; Lee, Jae-Hon; Kang, Eun-Ho; Yu, Bum-Hee
2012-09-01
Although specific temperaments have been known to be related to autonomic nervous function in some psychiatric disorders, there are few studies that have examined the relationship between temperaments and autonomic nervous function in a normal population. In this study, we examined the effect of temperament on the sympathetic nervous function in a normal population. Sixty eight healthy subjects participated in the present study. Temperament was assessed using the Korean version of the Cloninger Temperament and Character Inventory (TCI). Autonomic nervous function was determined by measuring skin temperature in a resting state, which was recorded for 5 minutes from the palmar surface of the left 5th digit using a thermistor secured with a Velcro® band. Pearson's correlation analysis and multiple linear regression were used to examine the relationship between temperament and skin temperature. A higher harm avoidance score was correlated with a lower skin temperature (i.e. an increased sympathetic tone; r=-0.343, p=0.004) whereas a higher persistence score was correlated with a higher skin temperature (r=0.433, p=0.001). Hierarchical linear regression analysis revealed that harm avoidance was able to predict the variance of skin temperature independently, with a variance of 7.1% after controlling for sex, blood pressure and state anxiety and persistence was the factor predicting the variance of skin temperature with a variance of 5.0%. These results suggest that high harm avoidance is related to an increased sympathetic nervous function whereas high persistence is related to decreased sympathetic nervous function in a normal population.
Temperament Affects Sympathetic Nervous Function in a Normal Population
Kim, Bora; Lee, Jae-Hon; Kang, Eun-Ho
2012-01-01
Objective Although specific temperaments have been known to be related to autonomic nervous function in some psychiatric disorders, there are few studies that have examined the relationship between temperaments and autonomic nervous function in a normal population. In this study, we examined the effect of temperament on the sympathetic nervous function in a normal population. Methods Sixty eight healthy subjects participated in the present study. Temperament was assessed using the Korean version of the Cloninger Temperament and Character Inventory (TCI). Autonomic nervous function was determined by measuring skin temperature in a resting state, which was recorded for 5 minutes from the palmar surface of the left 5th digit using a thermistor secured with a Velcro® band. Pearson's correlation analysis and multiple linear regression were used to examine the relationship between temperament and skin temperature. Results A higher harm avoidance score was correlated with a lower skin temperature (i.e. an increased sympathetic tone; r=-0.343, p=0.004) whereas a higher persistence score was correlated with a higher skin temperature (r=0.433, p=0.001). Hierarchical linear regression analysis revealed that harm avoidance was able to predict the variance of skin temperature independently, with a variance of 7.1% after controlling for sex, blood pressure and state anxiety and persistence was the factor predicting the variance of skin temperature with a variance of 5.0%. Conclusion These results suggest that high harm avoidance is related to an increased sympathetic nervous function whereas high persistence is related to decreased sympathetic nervous function in a normal population. PMID:22993530
A comparison of temperature profile depending on skin types for laser hair removal therapy.
Kim, Tae-Hoon; Lee, Gwi-Won; Youn, Jong-In
2014-11-01
Although numerous lasers with different wavelengths are available for laser hair removal, their use in individuals with dark-pigmented skin remains a challenge. The present study aims to develop a numerical heat diffusion model considering skin types over various wavelengths. This numerical mode uses Pennes approximation to represent heat from metabolism, blood perfusion and an external heating source. The heat diffusion model is experimentally validated by using agar-based skin tissue phantoms. Diode lasers with four different wavelengths were used with two antithetical skin models. The pulse width and beam spot size were set to 200 ms and 1 cm(2), respectively. Temperature distribution along the hair structure and skin tissue was examined to determine both thermal confinement and heat transfer to the hair follicle. Experimental results are well matched with the numerical results. The results show that for the light skin model, thermal confinement is well achieved over various wavelengths, and treatment efficacy is expected to be better at a shorter wavelength. Otherwise, for the dark skin model, thermal confinement is poorly achieved as the wavelength decreases (<808 nm) and the temperature gap between the hair tip and the hair root is significantly large compared with the light skin model, which may lead to adverse effects. We believe that the developed numerical model will help to establish optimal laser parameters for different individuals during laser hair removal.
NASA Astrophysics Data System (ADS)
Louie, Daniel C.; Tchvialeva, Lioudmilla; Zeng, Haishan; Lee, Tim K.
2017-02-01
Skin roughness is an important parameter in the characterization of skin and skin lesions, particularly for the purposes of skin cancer detection. Our group had previously constructed a laser speckle device that can detect the roughness in microrelief of the skin. This paper reports on findings made for the further miniaturization of our existing portably-sized device. These findings include the feasibility of adopting a laser diode without temperature control, and the use of a single CCD camera for detection. The coherence length of a laser is a crucial criterion for speckle measurements as it must be within a specific range. The coherence length of a commercial grade 405 nm laser diode was found to be of an appropriate length. Also, after a short warm-up period the coherence length of the laser was found to remain relatively stable, even without temperature control. Although the laser's temperature change during operation may affect its power output and the shape of its spectrum, these are only minor factors in speckle contrast measurements. Our second finding covers a calibration curve to relate speckle measurements to roughness using only parallel polarization from one CCD camera. This was created using experimental data from skin phantoms and tested on in-vivo skin. These improvements are important steps forward in the ongoing development of the laser speckle device, especially towards a clinical device to measure skin roughness and evaluate skin lesions.
Lee, Eunyoung; Lee, Bum-Jin; Ha, Jaehyoun; Shin, Hyun-Jung; Chung, Jin-Oh
2016-09-01
This study was aimed at assessing the therapeutic efficacy of green tea on peripheral skin for cold hypersensitive subjects, who had the feeling of cold hands and feet at cold temperatures, one of the most common complaints in Asian women. This randomized and placebo-controlled clinical study included 60 female Korean subjects who had the feeling of cold hands and feet at cold temperatures. The subjects were randomly assigned into two groups to receive fermented green tea or a placebo (hot water). The skin temperature of the hands and feet was measured using digital infrared thermography at the baseline and at 15, 30, 45, and 60 min after the oral administration of the tea or placebo. The skin temperature of the hands and feet of the fermented green tea-administered group was significantly higher than that of the placebo-administered group. The temperature difference between the finger and the dorsum of the hand was significantly lower in the fermented green tea-administered group than that in the placebo group. Fermented green tea is helpful for cold hypersensitivity. This is the first clinical study to evaluate the efficacy of fermented green tea on peripheral skin in subjects having the feeling of cold hands and feet at cold temperatures by infrared thermography. However, further studies are necessary to evaluate the long-term effects of the fermented green tea for cold hypersensitivity and to elucidate the underlying physiological mechanism. © 2015 Wiley Periodicals, Inc.
A multivariable model for predicting the frictional behaviour and hydration of the human skin.
Veijgen, N K; van der Heide, E; Masen, M A
2013-08-01
The frictional characteristics of skin-object interactions are important when handling objects, in the assessment of perception and comfort of products and materials and in the origins and prevention of skin injuries. In this study, based on statistical methods, a quantitative model is developed that describes the friction behaviour of human skin as a function of the subject characteristics, contact conditions, the properties of the counter material as well as environmental conditions. Although the frictional behaviour of human skin is a multivariable problem, in literature the variables that are associated with skin friction have been studied using univariable methods. In this work, multivariable models for the static and dynamic coefficients of friction as well as for the hydration of the skin are presented. A total of 634 skin-friction measurements were performed using a recently developed tribometer. Using a statistical analysis, previously defined potential influential variables were linked to the static and dynamic coefficient of friction and to the hydration of the skin, resulting in three predictive quantitative models that descibe the friction behaviour and the hydration of human skin respectively. Increased dynamic coefficients of friction were obtained from older subjects, on the index finger, with materials with a higher surface energy at higher room temperatures, whereas lower dynamic coefficients of friction were obtained at lower skin temperatures, on the temple with rougher contact materials. The static coefficient of friction increased with higher skin hydration, increasing age, on the index finger, with materials with a higher surface energy and at higher ambient temperatures. The hydration of the skin was associated with the skin temperature, anatomical location, presence of hair on the skin and the relative air humidity. Predictive models have been derived for the static and dynamic coefficient of friction using a multivariable approach. These two coefficients of friction show a strong correlation. Consequently the two multivariable models resemble, with the static coefficient of friction being on average 18% lower than the dynamic coefficient of friction. The multivariable models in this study can be used to describe the data set that was the basis for this study. Care should be taken when generalising these results. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Physiological and subjective responses to low relative humidity.
Sunwoo, Yujin; Chou, Chinmei; Takeshita, Junko; Murakami, Motoko; Tochihara, Yutaka
2006-01-01
In order to investigate the influence of low relative humidity, we measured saccharin clearance time (SCT), frequency of blinking, heart rate (HR), blood pressure, hydration state of skin, transepidermal water loss (TEWL), recovery sebum level and skin temperature as physiological responses. We asked subjects to judge thermal, dryness and comfort sensations as subjective responses using a rating scale. Sixteen non-smoking healthy male students were selected. The pre-room conditions were maintained at an air temperature (Ta) of 25 degrees C and a relative humidity (RH) of 50%. The test room conditions were adjusted to provide a Ta of 25 degrees C and RH levels of 10%, 30% and 50%.RH had no effect on the activity of the sebaceous gland and on cardiovascular reactions like blood pressure and HR. However, it was obvious that low RH affects SCT, the dryness of the ocular mucosa and the stratum corneum of the skin and causes a decrease in mean skin temperature. Under 30% RH, the eyes and skin become dry, and under 10% RH the nasal mucous membrane becomes dry as well as the eyes and skin, and the mean skin temperature decreases. These findings suggested that to avoid dryness of the eyes and skin, it is necessary to maintain an RH greater than 30%, and to avoid dryness of the nasal mucous membrane, it is necessary to maintain an RH greater than 10%. Subjects felt cold immediately after a change in RH while they had only a slight perception of dryness at the change of humidity.
Space Launch Complex 6 Wastewater Treatment Facilities Evaluation, Vandenberg AFB, California.
1987-02-01
Sgt Tammy Johnson, AiC Roberto Rolon and AlC Pete Davis without whose valuable assistance this survey could never have been accomplished. We also...lLt Francis E. Slavich, MSgt Horace C. Burbage, Sgt Tammy Johnson, AlCs Roberto Rolon and Pete Davis. The objectives of the survey were to evaluate the...TSK Brooks AFB TX 78235-5301 Defense Technical Information Center (DTIC) 2 Cameron Station Alexandria VA 22319 HQ USAF/LEEV 1 Bolling AFB DC 20330
1998-02-01
diet of higher trophic level species, such as raptors. Ord’s Kangaroo Rat (Dipodomys ordii). The Ord’s kangaroo rat is chiefly a nocturnal mammal...sandy soils. The entrances of these burrow systems are plugged during the day to maintain humidity and coolness. The kangaroo rat can obtain...sufficient quantities of water from the metabolism of food in their diet, but will drink water when it is available. TSK 0003/SWERA/Rev Final Rpt/November
Design of sports clothing for hot environments.
Varadaraju, R; Srinivasan, J
2018-02-22
The clothing design based on sweat distribution pattern is called as body mapping clothing. Comparisons of three designs of body mapped and one conventional design of T-shirt was done in a wearer testing at a controlled chamber of 33 °C and 60% relativity humidity in a treadmill at 12 km/h for 40 min followed by 10 min resting. It is concluded that with the full body mapped T-shirt the increase in skin temperature is reduced in the chest area, shoulder, the body back by 47%,44% and 55% respectively; the increase in skin micro climate relative humidity is reduced in the chest area, shoulder, the body back by 54%,39.2% and 53% respectively; the increase in heart beat rate is reduced by 5.1%; the subjective perceptions of skin temperature, skin moisture and comfort are better; the wearer will be able to improve the running performance due better comfort level in terms lesser increase skin temperature, skin micro climate relative humidity and heart beat rate. Copyright © 2018 Elsevier Ltd. All rights reserved.
Variation in skin biology to climate in Shanghai, China.
Liu, Xiaoping; Gao, Yanrui; Zhang, Yiyi; Wang, Xuemin
2017-09-01
To explore the relationship between climate and skin condition, and to investigate the variation of skin biology to climatic change. In total, 2005 healthy Chinese volunteers living in Shanghai (aged 13-69 years) were recruited. Transepidermal water loss (TEWL) and SCH were tested on six sites (forehead, cheek, nasolabial, inner forearm, dorsal hand, and palm) by noninvasive devices between January 2005 and December 2012. The corresponding climate data were recorded by local Weather Bureau. TEWL was increased with atmospheric pressure and decreased with temperature, steam pressure, and relative humidity (p < 0.05). SCH was increased with steam pressure and decreased with atmospheric pressure (p < 0.05); there was no obvious trend between SCH and temperature and SCH and relative humidity. To investigate the climate parameters together, we introduced these correlated factors into the multivariate linear regression model which demonstrated that temperature and steam pressure were main factors related to skin biological parameters. At different sites, the effect of climatic factors on skin biology was diverse. Skin biological parameters are associated with climatic factors. Different sites have different sensitivity to climate factors.
Female upper body and breast skin temperature and thermal comfort following exercise.
Ayres, B; White, J; Hedger, W; Scurr, J
2013-01-01
Breast support reduces breast pain and movement during exercise, however, an extra layer of clothing may affect thermoregulation. This preliminary study investigated female upper body and breast skin temperature and thermal comfort following short-duration exercise. Eight female participants with C-cup breasts had thermal images (infra-red camera, FLIR systems) of the bare breasts, the breasts in two sports bras (composite and polyester) and the abdomen, taken before and after 20 min of exercise at 28(o)C. Following exercise, bare-breast, bra and abdomen temperatures reduced by 0.61(o)C, 0.92(o)C and 2.06(o)C, respectively. The polyester sports bra demonstrated greater thermal comfort and enabled a greater change in skin temperature than the composite sports bra. It is concluded that following short-duration exercise, sports bras reduced the cooling ability of the breast. Material properties of the bras affect thermal comfort and post-exercise skin temperature; this should be an important consideration for sports bra manufacturers. This study investigates the effect of sports bras on thermal regulation of the breast following exercise. Sports bras negatively affected the cooling ability of the skin on the breast, with the material properties of the bra affecting thermal comfort following exercise. These results present important considerations for sports bra manufacturers.
NASA Astrophysics Data System (ADS)
Prats, Jordi; Reynaud, Nathalie; Rebière, Delphine; Peroux, Tiphaine; Tormos, Thierry; Danis, Pierre-Alain
2018-04-01
The spatial and temporal coverage of the Landsat satellite imagery make it an ideal resource for the monitoring of water temperature over large territories at a moderate spatial and temporal scale at a low cost. We used Landsat 5 and Landsat 7 archive images to create the Lake Skin Surface Temperature (LakeSST) data set, which contains skin water surface temperature data for 442 French water bodies (natural lakes, reservoirs, ponds, gravel pit lakes and quarry lakes) for the period 1999-2016. We assessed the quality of the satellite temperature measurements by comparing them to in situ measurements and taking into account the cool skin and warm layer effects. To estimate these effects and to investigate the theoretical differences between the freshwater and seawater cases, we adapted the COARE 3.0 algorithm to the freshwater environment. We also estimated the warm layer effect using in situ data. At the reservoir of Bimont, the estimated cool skin effect was about -0.3 and -0.6 °C most of time, while the warm layer effect at 0.55 m was negligible on average, but could occasionally attain several degrees, and a cool layer was often observed in the night. The overall RMSE of the satellite-derived temperature measurements was about 1.2 °C, similar to other applications of satellite images to estimate freshwater surface temperatures. The LakeSST data can be used for studies on the temporal evolution of lake water temperature and for geographical studies of temperature patterns. The LakeSST data are available at https://doi.org/10.5281/zenodo.1193745.
... system. One of the main functions of the skin is protection. It protects the body from external factors such as bacteria, chemicals, and temperature. The skin contains secretions that can kill bacteria and the ...
Zheng, Yun; Li, Jin-Qing; Chen, Min-Shan; Zhang, Yao-Jun; Zhang, Ya-Qi
2004-11-01
The application and development of traditional percutaneous microwave coagulation therapy (PMCT) has been limited by high shaft temperature. The "air-cooled" PMCT is the newest advancement. This study was to compare shaft temperature related treatment efficacy between "air-cooled" PMCT and traditional PMCT. Two pigs underwent traditional PMCT, and "air-cooled" PMCT at 80 W for 10 min separately. Skin injury, surface temperature of guide-needle, charring tissue sticking to the shaft, and lesion shape in 2 pigs were compared. Five patients with liver tumor received traditional PMCT, and 8 patients with liver tumor received "air-cooled" PMCT. Feeling of pain, skin injury, charring tissue sticking to the shaft, local therapeutic efficacy, and recurrence of these 2 groups of patients were compared. In the pig underwent traditional PMCT, surface temperature of guide-needle reached 119-160 Centigrade; skin burn around puncture points was serious; charring tissue stuck to the front of electrodes; a trail sign was observed in coagulated lesion. In the pig underwent "air-cooled" PMCT, surface temperature of guide-needle was 28.8-39.9 Centigrade; no skin injury was found around puncture points; no charring tissue stuck to the front of electrodes; no obvious trail sign was observed in coagulated lesion. In 5 patients received traditional PMCT, 3 had skin injury; 2 had charring tissue stuck to the front of electrode; all felt moderate or serious epigastric pain lasted for 1-8 weeks; 4 had complete coagulation; 1 had local recurrence. In 8 patients received "air-cooled" PMCT, no one had skin injury, and charring tissue stuck to "air-cooled" electrode; 4 felt slight epigastric pain within 1 week; all had complete coagulation; no local recurrence was found. The technique of "air-cooled" electrode may decrease temperature of shaft safely and reliably, and eliminate side effects arose from high temperature of shaft. Treatment efficacy of "air-cooled" PMCT is better than that of traditional PMCT.
Baldus, Sandra; Kluth, Karsten; Strasser, Helmut
2012-01-01
So far, it was unclear to what extent working in deep cold-storage depots has an influence on female order-pickers body core temperature and skin surface temperature considering different age groups. Physiological effects of order-picking in a chill room (+3°C) and cold store (-24°C) were examined on 30 female subjects (Ss), classified in two age groups (20- to 35- year-olds and 40- to 65-year-olds). The body core temperature was taken every 15 min at the tympanum and the skin surface temperature was recorded continuously at seven different positions. Working in the chill room induced a decrease of the body core temperature up to 0.5K in comparison to the value at the outset for both age groups which could be compensated by all Ss during the breaks. Working in the cold store caused a decline up to 1.1K for the younger Ss and 1.3K for the older Ss. A complete warming-up during the breaks was often not possible. Regarding the skin surface temperature, working in the chill room can be considered as unproblematic, whereas significantly lower temperatures at nose, fingers and toes, associated with substantial negative subjective sensations, were recorded while working in the cold store.
Mao, G; Flach, C R; Mendelsohn, R; Walters, R M
2012-08-01
To image SDS distribution across different skin regions, to compare the permeability difference between porcine and human skin, and to evaluate the interaction between SDS and skin. Full thickness porcine and human skin was treated with acyl chain perdeuterated SDS (SDS-d(25)) at room temperature and at 34 °C for 3, 24 and 40 h. SDS distribution in skin was monitored by confocal Raman and IR microspectroscopic imaging. Permeation profiles of SDS-d(25) in skin were derived from the band intensities of the CD(2) stretching vibrations. The interaction between SDS and skin was monitored through the CH(2) and CD(2) stretching frequencies and the Amide I and II spectral region. SDS-d(25) penetrates both porcine and human skin in a time and temperature-dependent manner, with slightly higher permeability through the stratum corneum (SC) in porcine skin. When SDS permeates into the SC, its chains are more ordered compared to SDS micelles. The secondary structure of keratin in the SC is not affected by SDS-d(25). The spatial distribution of SDS-d(25) in skin was obtained for the first time. Infrared microscopic imaging provides unique opportunities to measure concentration profiles of exogenous materials in skin and offers insights to interaction between permeants and skin.
Physical Retrieval of Surface Emissivity Spectrum from Hyperspectral Infrared Radiances
NASA Technical Reports Server (NTRS)
Li, Jun; Weisz, Elisabeth; Zhou, Daniel K.
2007-01-01
Retrieval of temperature, moisture profiles and surface skin temperature from hyperspectral infrared (IR) radiances requires spectral information about the surface emissivity. Using constant or inaccurate surface emissivities typically results in large retrieval errors, particularly over semi-arid or arid areas where the variation in emissivity spectrum is large both spectrally and spatially. In this study, a physically based algorithm has been developed to retrieve a hyperspectral IR emissivity spectrum simultaneously with the temperature and moisture profiles, as well as the surface skin temperature. To make the solution stable and efficient, the hyperspectral emissivity spectrum is represented by eigenvectors, derived from the laboratory measured hyperspectral emissivity database, in the retrieval process. Experience with AIRS (Atmospheric InfraRed Sounder) radiances shows that a simultaneous retrieval of the emissivity spectrum and the sounding improves the surface skin temperature as well as temperature and moisture profiles, particularly in the near surface layer.
ERIC Educational Resources Information Center
Tansey, E. A.; Roe, S. M.; Johnson, C. J.
2014-01-01
When a subject is heated, the stimulation of temperature-sensitive nerve endings in the skin, and the raising of the central body temperature, results in the reflex release of sympathetic vasoconstrictor tone in the skin of the extremities, causing a measurable temperature increase at the site of release. In the sympathetic release test, the…
Yamamoto, Yuki; Yamamoto, Daisuke; Takada, Makoto; Naito, Hiroyoshi; Arie, Takayuki; Akita, Seiji; Takei, Kuniharu
2017-09-01
Wearable, flexible healthcare devices, which can monitor health data to predict and diagnose disease in advance, benefit society. Toward this future, various flexible and stretchable sensors as well as other components are demonstrated by arranging materials, structures, and processes. Although there are many sensor demonstrations, the fundamental characteristics such as the dependence of a temperature sensor on film thickness and the impact of adhesive for an electrocardiogram (ECG) sensor are yet to be explored in detail. In this study, the effect of film thickness for skin temperature measurements, adhesive force, and reliability of gel-less ECG sensors as well as an integrated real-time demonstration is reported. Depending on the ambient conditions, film thickness strongly affects the precision of skin temperature measurements, resulting in a thin flexible film suitable for a temperature sensor in wearable device applications. Furthermore, by arranging the material composition, stable gel-less sticky ECG electrodes are realized. Finally, real-time simultaneous skin temperature and ECG signal recordings are demonstrated by attaching an optimized device onto a volunteer's chest. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Okuyama, Mayumi; Nishida, Masumi
2016-01-01
The aim of the present study was to examine the association between impending dehydration among elderly people in nursing homes and physical signs, including the axillary skin temperature, humidity, intraoral moisture content, and salivary components. The study included 78 elderly individuals who required long-term care in a nursing home (11 men and 67 women; average age, 86.6±7.3 years). The elderly subjects were classified in two groups according to their serum osmolality levels: those with levels between the upper limit reference value (292 mOsm/kg H2O) and the diagnostic reference value of dehydration (300 mOsm/kg H2O) were classified into the boundary zone group and those with levels of <292 mOsm/kg H2O were classified into the normal range group. The following parameters were measured: basic attributes (age, gender and level of care required), body mass index, diet, daily fluid intake per kilogram of body weight, physiological indicators (blood pressure, pulse rate, body temperature, axillary skin temperature, humidity, total body water, body water rate, internal liquid rate, external solution rate, blood components, intraoral water amount, and salivary components), and the indoor environment (room temperature and humidity). We then performed a statistical analysis to compare the boundary zone group with the normal range group. After adjusting for age and the daily fluid intake per kilogram of body weight (<25 ml/≥25 ml), we performed a logistic regression analysis (the boundary zone group was used as an independent variable) for variables that had significance levels of <0.05 (except for blood components). The univariate analysis revealed significant differences in the following parameters: the serum sodium, chloride, and creatinine levels; the blood sugar level; the urea nitrogen/creatinine ratio; the axillary skin temperature; and room humidity. Only the axillary skin temperature showed a significant association in the final model of the logistic regression analysis (odds ratio, 3.664; 95% confidence interval, 1.101-12.197; p = 0.034). As the axillary skin temperature increased by 1°C, there was a 3.67-fold risk of being classified into the boundary zone group instead of the normal range group. Thus, the axillary skin temperature was associated with impending dehydration.
Renero-C, Francisco-J
2017-01-01
Background : Thermoregulation is a complex autonomic process to keep or to dissipate heat in the human body. Methods : In this work, by means of the thermogram of the plantar skin, the thermoregulation of healthy individuals, overweight-obese, and diabetic is discussed. Results : The thermograms of the plantar skin, for the healthy individuals, are: (1) symmetrical, the temperature distribution of the right foot being a mirror image of that of the left foot ; (2) the thermograms of women, on average, are 3°C colder than those of the men; and (3) the temperature distributions decrease distally from the medial longitudinal arch. The plantar skin thermograms of overweight-obese individuals show: (1) increased average temperature of both feet and for both genders; (2) no symmetry between the left and right feet thermograms; and (3) the temperature distribution is still decreasing from the medial longitudinal arch to the periphery of the foot. However, the standard deviation, for each averaged temperature of the angiosomes, shows greater uncertainty. Most thermograms of diabetic individuals show temperature increase on the plantar skin, and are mostly symmetric between left and right feet. Conclusions: An asymmetric thermogram of the plantar skin of diabetic individuals, where one foot is hotter than the other, may mean that the coldest foot is losing the capacity to communicate properly with the central nervous system and/or that vasoconstriction/vasodilatation is having problems in regulating the passing of blood through the vessels. Thus, the asymmetric thermograms of diabetic patients, and particularly those coldest regions of foot are of interest, because of the reduction of the local autonomic sensing and the lack of achieving properly the passing of the blood.
Definition of the thermographic regions of interest in cycling by using a factor analysis
NASA Astrophysics Data System (ADS)
Priego Quesada, Jose Ignacio; Lucas-Cuevas, Angel Gabriel; Salvador Palmer, Rosario; Pérez-Soriano, Pedro; Cibrián Ortiz de Anda, Rosa M.a.
2016-03-01
Research in exercise physiology using infrared thermography has increased in the last years. However, the definition of the Regions of Interest (ROIs) varies strongly between studies. Therefore, the aim of this study was to use a factor analysis approach to define highly correlated groups of thermographic ROIs during a cycling test. Factor analyses were performed based on the moment of measurement and on the variation of skin temperatures as a result of the cycling exercise. 19 male participants cycled during 45 min at 50% of their individual peak power output with a cadence of 90 rpm. Infrared thermography was used to measure skin temperatures in sixteen ROIs of the trunk and lower limbs at three moments: before, immediately after and 10 min after the cycling test. Factor analyses were used to identify groups of ROIs based on the skin absolute temperatures at each moment of measurement as well as on skin temperature variations between moments. All the factor analyses performed for each moment and skin temperature variation explained more than the 80% of the variance. Different groups of ROIs were obtained when the analysis was based on the moment of measurement or on the effect of exercise on the skin temperature. Furthermore, some ROIs were grouped in the same way in both analyses (e.g. the ROIs of the trunk), whereas other regions (legs and their joints) were grouped differently in each analysis. Differences between groups of ROIs are related to their tissue composition, muscular activity and capacity of sweating. In conclusion, the resultant groups of ROIs were coherent and could help researchers to define the ROIs in future thermal studies.
Air conditioner operation behaviour based on students' skin temperature in a classroom.
Song, Gook-Sup; Lim, Jae-Han; Ahn, Tae-Kyung
2012-01-01
A total of 25 college students participated in a study to determine when they would use an air conditioner during a lecture in a university classroom. The ambient temperature and relative humidity were measured 75 cm above the floor every minute. Skin temperatures were measured every minute at seven points, according to the recommendation of Hardy and Dubois. The average clothing insulation value (CLO) of subjects was 0.53 ± 0.07 CLO. The mean air velocity in the classroom was 0.13 ± 0.028 m/s. When the subjects turned the air conditioner both on and off, the average ambient temperatures, relative humidity and mean skin temperatures were 27.4 and 23.7 °C (p = 0.000), 40.9 and 40.0% (p = 0.528) and 32.7 and 32.2 °C (p = 0.024), respectively. When the status of the air conditioner was changed, the differences of skin temperatures in core body parts (head, abdomen and thigh) were not statistically significant. However, in the extremities (mid-lower arm, hand, shin and instep), the differences were statistically significant. Subjects preferred a fluctuating environment to a constant temperature condition. We found that a changing environment does not affect classroom study. Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Skin temperature reveals the intensity of acute stress
Herborn, Katherine A.; Graves, James L.; Jerem, Paul; Evans, Neil P.; Nager, Ruedi; McCafferty, Dominic J.; McKeegan, Dorothy E.F.
2015-01-01
Acute stress triggers peripheral vasoconstriction, causing a rapid, short-term drop in skin temperature in homeotherms. We tested, for the first time, whether this response has the potential to quantify stress, by exhibiting proportionality with stressor intensity. We used established behavioural and hormonal markers: activity level and corticosterone level, to validate a mild and more severe form of an acute restraint stressor in hens (Gallus gallus domesticus). We then used infrared thermography (IRT) to non-invasively collect continuous temperature measurements following exposure to these two intensities of acute handling stress. In the comb and wattle, two skin regions with a known thermoregulatory role, stressor intensity predicted the extent of initial skin cooling, and also the occurrence of a more delayed skin warming, providing two opportunities to quantify stress. With the present, cost-effective availability of IRT technology, this non-invasive and continuous method of stress assessment in unrestrained animals has the potential to become common practice in pure and applied research. PMID:26434785
Skin temperature reveals the intensity of acute stress.
Herborn, Katherine A; Graves, James L; Jerem, Paul; Evans, Neil P; Nager, Ruedi; McCafferty, Dominic J; McKeegan, Dorothy E F
2015-12-01
Acute stress triggers peripheral vasoconstriction, causing a rapid, short-term drop in skin temperature in homeotherms. We tested, for the first time, whether this response has the potential to quantify stress, by exhibiting proportionality with stressor intensity. We used established behavioural and hormonal markers: activity level and corticosterone level, to validate a mild and more severe form of an acute restraint stressor in hens (Gallus gallus domesticus). We then used infrared thermography (IRT) to non-invasively collect continuous temperature measurements following exposure to these two intensities of acute handling stress. In the comb and wattle, two skin regions with a known thermoregulatory role, stressor intensity predicted the extent of initial skin cooling, and also the occurrence of a more delayed skin warming, providing two opportunities to quantify stress. With the present, cost-effective availability of IRT technology, this non-invasive and continuous method of stress assessment in unrestrained animals has the potential to become common practice in pure and applied research. Copyright © 2015 Elsevier Inc. All rights reserved.
Harada, Shingo; Kanao, Kenichiro; Yamamoto, Yuki; Arie, Takayuki; Akita, Seiji; Takei, Kuniharu
2014-12-23
A three-axis tactile force sensor that determines the touch and slip/friction force may advance artificial skin and robotic applications by fully imitating human skin. The ability to detect slip/friction and tactile forces simultaneously allows unknown objects to be held in robotic applications. However, the functionalities of flexible devices have been limited to a tactile force in one direction due to difficulties fabricating devices on flexible substrates. Here we demonstrate a fully printed fingerprint-like three-axis tactile force and temperature sensor for artificial skin applications. To achieve economic macroscale devices, these sensors are fabricated and integrated using only printing methods. Strain engineering enables the strain distribution to be detected upon applying a slip/friction force. By reading the strain difference at four integrated force sensors for a pixel, both the tactile and slip/friction forces can be analyzed simultaneously. As a proof of concept, the high sensitivity and selectivity for both force and temperature are demonstrated using a 3×3 array artificial skin that senses tactile, slip/friction, and temperature. Multifunctional sensing components for a flexible device are important advances for both practical applications and basic research in flexible electronics.
Polidori, G; Marreiro, A; Pron, H; Lestriez, P; Boyer, F C; Quinart, H; Tourbah, A; Taïar, R
2016-11-01
This article establishes the basics of a theoretical model for the constitutive law that describes the skin temperature and thermolysis heat losses undergone by a subject during a session of whole-body cryotherapy (WBC). This study focuses on the few minutes during which the human body is subjected to a thermal shock. The relationship between skin temperature and thermolysis heat losses during this period is still unknown and have not yet been studied in the context of the whole human body. The analytical approach here is based on the hypothesis that the skin thermal shock during a WBC session can be thermally modelled by the sum of both radiative and free convective heat transfer functions. The validation of this scientific approach and the derivation of temporal evolution thermal laws, both on skin temperature and dissipated thermal power during the thermal shock open many avenues of large scale studies with the aim of proposing individualized cryotherapy protocols as well as protocols intended for target populations. Furthermore, this study shows quantitatively the substantial imbalance between human metabolism and thermolysis during WBC, the explanation of which remains an open question. Copyright © 2016 Elsevier Ltd. All rights reserved.
Cutaneous Heat Loss with Three Surgical Drapes, One Impervious to Moisture
Maglinger, Paul E.; Sessler, Daniel I.; Lenhardt, Rainer
2005-01-01
A new surgical drape, which is impervious to moisture, presumably reduces evaporative heat loss. We compared cutaneous heat loss and skin temperature in volunteers covered with this drape to two conventional surgical drapes (Large Surgical Drape and Medline Proxima). With IRB approval and informed consent, we calculated cutaneous heat loss and skin-surface temperatures from 15 area-weighted thermal flux transducers in 8 volunteers. In random order, each of the drapes was evaluated with dry transducers and moistened transducers (simulating wet skin). After a 20-minute uncovered control period, volunteers were covered from the neck down for 40 minutes. Data were recorded continuously and averaged over 10-minutes. Results were similar for all three drapes for dry or moist conditions. Under dry conditions, baseline heat loss was 82±14 watts (W) and decreased 30% with a surgical drape (P<0.001). Under moist conditions, baseline heat loss was 231±45 W and decreased 29% with a drape covering (P<0.001). Moist skin increased heat loss 282% (P<0.001). There were no clinically important differences in skin temperature among the covers with dry or moist skin. Moist skin increased heat loss nearly three-fold, but there were no differences among the drapes. We conclude that loss is comparable with impervious and conventional drapes with either moist or dry skin. PMID:15728062
The effect of compressed air massage on skin blood flow and temperature.
Mars, Maurice; Maharaj, Sunil S; Tufts, Mark
2005-01-01
Compressed air massage is a new treatment modality that uses air under pressure to massage skin and muscle. It is claimed to improve skin blood flow but this has not been verified. Several pilot studies were undertaken to determine the effects of compressed air massage on skin blood flow and temperature. Skin blood flow (SBF), measured using laser Doppler fluxmetry and skin temperature was recorded under several different situations: (i) treatment, at 1 Bar pressure using a single-hole (5-mm) applicator head, for 1 min at each of several sites on the right and left lower legs, with SBF measured on the dorsum of the left foot; (ii) at the same treatment pressure, SBF was measured over the left tibialis anterior when treatment was performed at different distances from the probe; (iii) SBF and skin temperature of the lower leg were measured with treatment at 0 or 1 Bar for 45 min, using two different applicator heads; (iv) SBF was measured on the dorsum of the foot of 10 subjects with treatment for 1 min at 0, 0.5, 1, 1.5 and 2 Bar using three different applicator heads. (i) SBF of the left foot was not altered by treatment of the right leg or chest, but was significantly increased during treatment of the left sole and first web, p < 0.0001. (ii) SBF over the tibialis anterior was increased when treatment was 5 cm from the probe, p < 0.0001, but not when 10 cm away. iii) SBF was significantly elevated throughout the 45-min treatments at 1 Bar and returned to normal within 1 min of stopping treatment. Skin temperature fell by 6.8 degrees C and 4.3 degrees C after 45-min treatments at 1 Bar, and slight rewarming occurred within 15 min. At 0 Bar, no change in SBF or temperature was noted. (iv) A near-linear increase in SBF was noted with increasing treatment pressure for two of the three applicator heads. Compressed air massage causes an immediate increase in SBF, and an immediate fall in SBF when treatment is stopped. The effect appears to be locally and not centrally mediated and is related to the pressure used. Treatment cools the skin for at least 15 min after a 45-min treatment.
In-flight boundary-layer measurements on a hollow cylinder at a Mach number of 3.0
NASA Technical Reports Server (NTRS)
Quinn, R. D.; Gong, L.
1980-01-01
Skin temperatures, shear forces, surface static pressures, boundary layer pitot pressures, and boundary layer total temperatures were measured on the external surface of a hollow cylinder that was 3.04 meters long and 0.437 meter in diameter and was mounted beneath the fuselage of the YF-12A airplane. The data were obtained at a nominal free stream Mach number of 3.0 (a local Mach number of 2.9) and at wall to recovery temperature ratios of 0.66 to 0.91. The local Reynolds number had a nominal value of 4,300,000 per meter. Heat transfer coefficients and skin friction coefficients were derived from skin temperature time histories and shear force measurements, respectively. In addition, boundary layer velocity profiles were derived from pitot pressure measurements, and a Reynolds analogy factor was obtained from the heat transfer and skin friction measurements. The measured data are compared with several boundary layer prediction methods.
Studying the effects of the heat stress on the various layers of human skin using damage function
NASA Astrophysics Data System (ADS)
Aijaz, Mir; Khanday, M. A.
2016-03-01
This paper develops a model to identify the effects of thermal stress on temperature distribution and damage in human dermal regions. The design and selection of the model takes into account many factors effecting the temperature distribution of skin, e.g., thermal conductance, perfusion, metabolic heat generation and thermal protective capabilities of the skin. The transient temperature distribution within the region is simulated using a two-dimensional finite element model of the Pennes’ bioheat equation. The relationship between temperature and time is integrated to view the damage caused to human skin by using Henriques’ model Henriques, F. C., Arch. Pathol. 43 (1947) 489-502]. The Henriques’ damage model is found to be more desirable for use in predicting the threshold of thermal damage. This work can be helpful in both emergency medicines as well as to plastic surgeon in deciding upon a course of action for the treatment of different burn injuries.
Maley, Matthew J; Minett, Geoffrey M; Bach, Aaron J E; Zietek, Stephanie A; Stewart, Kelly L; Stewart, Ian B
2018-01-01
The present study aimed to compare a range of cooling methods possibly utilised by occupational workers, focusing on their effect on body temperature, perception and manual dexterity. Ten male participants completed eight trials involving 30 min of seated rest followed by 30 min of cooling or control of no cooling (CON) (34°C, 58% relative humidity). The cooling methods utilised were: ice cooling vest (CV0), phase change cooling vest melting at 14°C (CV14), evaporative cooling vest (CVEV), arm immersion in 10°C water (AI), portable water-perfused suit (WPS), heliox inhalation (HE) and ice slushy ingestion (SL). Immediately before and after cooling, participants were assessed for fine (Purdue pegboard task) and gross (grip and pinch strength) manual dexterity. Rectal and skin temperature, as well as thermal sensation and comfort, were monitored throughout. Compared with CON, SL was the only method to reduce rectal temperature (P = 0.012). All externally applied cooling methods reduced skin temperature (P<0.05), though CV0 resulted in the lowest skin temperature versus other cooling methods. Participants felt cooler with CV0, CV14, WPS, AI and SL (P<0.05). AI significantly impaired Purdue pegboard performance (P = 0.001), but did not affect grip or pinch strength (P>0.05). The present study observed that ice ingestion or ice applied to the skin produced the greatest effect on rectal and skin temperature, respectively. AI should not be utilised if workers require subsequent fine manual dexterity. These results will help inform future studies investigating appropriate pre-cooling methods for the occupational worker.
Structure and Function of Skin: The Application of THz Radiation in Dermatology
NASA Astrophysics Data System (ADS)
Jo, Seong Jin; Kwon, Oh Sang
Skin, the largest organ of human being, is a soft membrane covering the exterior of the body. It protects the host from mechanical injuries, toxic materials, pathogenic organisms, and so on. Although its basic function is protection from the environment like this, it is not a simple and static shield but a complex and dynamic organ which performs important roles in maintaining the homeostasis of the body. Skin controls evaporation to prevent massive water loss, and regulates body temperature by controlling the blood flow of skin and perspiration [1]. It is responsible for the synthesis of vitamin D and a storage center for lipid and water. In addition, skin contains nerve endings and provides sensation for temperature, touch, pressure, and vibration.
NASA Astrophysics Data System (ADS)
Sari, Ellyta; Pasymi; Khatab, Umar; Desmiarti, Reni; Ariansyah, Rian; Hariadi; Sutra
2018-03-01
Biobriquettes as alternative energy that can replace the role of kerosene. Biobriquettes made from agricultural waste biomass. Biobriquettes durian peel has been researched and developed continuously to obtain optimal quality in terms of calorific value, compressive strength and duration of ignition. In making durian peel biobriquettes needed other biomass mix to sustain duration of Ignition for biobriquettes durian skin quickly burned out. Stages of making biobriquettes durian skin are: material of drying, carbonization of biomass, grinding, mixing with adhesives, and printing. Carbonization process is a process that is important in obtaining the biomass charcoal. Carbonization is done by means of karbonisator pyrolysis. The purpose of this research is to study the process of carbonization to obtain biobriquettes durian skin that of quality in terms of value compressive strength, calorific value, and duration of ignition. Variations that done was kind mix of biomass,coconut shells and palm shells with the massa ratio 2 : 1, type of adhesive used tapioca powder and banana peels, carbonization of temperature 200°C. 300°C and 400 °C. The results showed that the highest compressive strength of the durian skin with a mixture of coconut shell and adhesive tapioca powder and carbonization temperature of 300 °C namely 12,7 g/cm2. The calorific value of the highest on the mix of skin durian with coconut shells and adhesive banana skin with temperature of carbonization 400 °C ie 6040 cal/g, and duration of ignition highest on a mixture of skin durian with coconut shell and adhesive banana skin at a temperature of carbonization 300 °C is 73 minutes.
Kaewruang, Phanngam; Benjakul, Soottawat; Prodpran, Thummanoon
2013-06-01
Gelatins extracted from the skin of unicorn leatherjacket at different temperatures (45, 55, 65 and 75°C) in the presence and the absence of soybean trypsin inhibitor (SBTI; 100 units/g pretreated skin) for 12h were characterised. In general, the addition of SBTI resulted in the lower yield, regardless of extraction temperature. Higher yield was obtained when higher extraction temperature was used (P<0.05). Gelatin from skin extracted at 75°C in the absence of SBTI showed the highest yield (10.66 ± 0.41%) (based on dry weight). The highest α-amino group content was observed in gelatin extracted at 55°C without SBTI incorporated. The band intensity of β-chain and α-chains increased as the extraction temperature increased, particularly above 55°C. Gelatin extracted at 65°C with and without SBTI incorporation exhibited the highest gel strength (178.00 ± 7.50 g and 170.47 ± 1.30 g, respectively). FTIR spectra indicated that a greater loss of molecular order of triple helix with a higher degradation was found in gelatin extracted at 55°C in the absence SBTI. Gelatin extracted at 65°C, either with or without SBTI, had the highest EAI and ESI with high foam expansion and stability. Thus, the extraction of gelatin from the skin of unicorn leatherjacket at temperature sufficiently high could render the gelatin with less degradation. Copyright © 2012 Elsevier Ltd. All rights reserved.
Källman, Ulrika; Engström, Maria; Bergstrand, Sara; Ek, Anna-Christina; Fredrikson, Mats; Lindberg, Lars-Göran; Lindgren, Margareta
2015-03-01
Although repositioning is considered an important intervention to prevent pressure ulcers, tissue response during loading in different lying positions has not been adequately explored. To compare the effects of different lying positions on interface pressure, skin temperature, and tissue blood flow in nursing home residents. From May 2011 to August 2012, interface pressure, skin temperature, and blood flow at three tissue depths were measured for 1 hr over the sacrum in 30° supine tilt and 0° supine positions and over the trochanter major in 30° lateral and 90° lateral positions in 25 residents aged 65 years or older. Measurement of interface pressure was accomplished using a pneumatic pressure transmitter connected to a digital manometer, skin temperature using a temperature sensor, and blood flow using photoplethysmography and laser Doppler flowmetry. Interface pressure was significantly higher in the 0° supine and 90° lateral positions than in 30° supine tilt and 30° lateral positions. The mean skin temperature increased from baseline in all positions. Blood flow was significantly higher in the 30° supine tilt position compared to the other positions. A hyperemic response in the post pressure period was seen at almost all tissue depths and positions. The 30° supine tilt position generated less interface pressure and allowed greater tissue perfusion, suggesting that this position is the most beneficial. © The Author(s) 2014.
Validation of a new whole-body cryotherapy chamber based on forced convection.
Bouzigon, Romain; Arfaoui, Ahlem; Grappe, Frédéric; Ravier, Gilles; Jarlot, Benoit; Dugue, Benoit
2017-04-01
Whole-body cryotherapy (WBC) and partial-body cryotherapy (PBC) are two methods of cold exposure (from -110 to -195°C according to the manufacturers). However, temperature measurement in the cold chamber during a PBC exposure revealed temperatures ranging from -25 to -50°C next to the skin of the subjects (using isolating layer placed between the sensor and the skin). This discrepancy is due to the human body heat transfer. Moreover, on the surface of the body, an air layer called the boundary layer is created during the exposure and limits heat transfer from the body to the cabin air. Incorporating forced convection in a chamber with a participant inside could reduce this boundary layer. The aim of this study was to explore the use of a new WBC technology based on forced convection (frontal unilateral wind) through the measurement of skin temperature. Fifteen individuals performed a 3-min WBC exposure at -40°C with an average wind speed of 2.3ms -1 . The subjects wore a headband, a surgical mask, underwear, gloves and slippers. The skin temperature of the participants was measured with a thermal camera just before exposure, just after exposure and at 1, 3, 5, 10, 15 and 20min after exposure. Mean skin temperature significantly dropped by 11°C just after exposure (p<0.001) and then significantly increased during the 20-min post exposure period (p<0.001). No critically low skin temperature was observed at the end of the cold exposure. This decrease was greater than the mean decreases in all the cryosauna devices with reported exposures between -140°C and -160°C and those in two other WBC devices with reported exposures between -60°C and -110°C. The use of this new technology provides the ability to reach decreases in skin temperature similar to other technologies. The new chamber is suitable and relevant for use as a WBC device. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Egbunike, G. N.; Ogunmola, A. L.; Amakiri, S. F.
1983-09-01
The relative importance of dry- and wet-bulb temperatures on cutaneous function in Bos indicus and Bos taurus females under humid tropical climatic conditions was evaluated. The parameters investigated were sweating rate and skin temperature, while the species utilised were zebu White Fulani ( Bos indicus) and German Brown and German Black and White ( Bos taurus). The sweating rate, irrespective of breed, differed with the site of sampling and was more influenced by dry-bulb (59%) than by wet-bulb temperature (41%). Skin temperature responded more to wet-bulb temperature in White Fulani and German Black and White cattle, but not in German Brown cattle. It is concluded that the response of the animals, with respect to sweating, was similar but that the efficiency of sweating, judged by the lowering of skin temperature, was higher in Bos indicus than in Bos taurus. This, in part, may explain the higher degree of comfort demonstrated by Bos indicus under tropical conditions.
Zhang, Fengjiao; Zang, Yaping; Huang, Dazhen; Di, Chong-an; Zhu, Daoben
2015-09-21
Skin-like temperature- and pressure-sensing capabilities are essential features for the next generation of artificial intelligent products. Previous studies of e-skin and smart elements have focused on flexible pressure sensors, whereas the simultaneous and sensitive detection of temperature and pressure with a single device remains a challenge. Here we report developing flexible dual-parameter temperature-pressure sensors based on microstructure-frame-supported organic thermoelectric (MFSOTE) materials. The effective transduction of temperature and pressure stimuli into two independent electrical signals permits the instantaneous sensing of temperature and pressure with an accurate temperature resolution of <0.1 K and a high-pressure-sensing sensitivity of up to 28.9 kPa(-1). More importantly, these dual-parameter sensors can be self-powered with outstanding sensing performance. The excellent sensing properties of MFSOTE-based devices, together with their unique advantages of low cost and large-area fabrication, make MFSOTE materials possess promising applications in e-skin and health-monitoring elements.
NASA Astrophysics Data System (ADS)
Zhang, Fengjiao; Zang, Yaping; Huang, Dazhen; di, Chong-An; Zhu, Daoben
2015-09-01
Skin-like temperature- and pressure-sensing capabilities are essential features for the next generation of artificial intelligent products. Previous studies of e-skin and smart elements have focused on flexible pressure sensors, whereas the simultaneous and sensitive detection of temperature and pressure with a single device remains a challenge. Here we report developing flexible dual-parameter temperature-pressure sensors based on microstructure-frame-supported organic thermoelectric (MFSOTE) materials. The effective transduction of temperature and pressure stimuli into two independent electrical signals permits the instantaneous sensing of temperature and pressure with an accurate temperature resolution of <0.1 K and a high-pressure-sensing sensitivity of up to 28.9 kPa-1. More importantly, these dual-parameter sensors can be self-powered with outstanding sensing performance. The excellent sensing properties of MFSOTE-based devices, together with their unique advantages of low cost and large-area fabrication, make MFSOTE materials possess promising applications in e-skin and health-monitoring elements.
Muscle, Skin and Core Temperature after −110°C Cold Air and 8°C Water Treatment
Costello, Joseph Thomas; Culligan, Kevin; Selfe, James; Donnelly, Alan Edward
2012-01-01
The aim of this investigation was to elucidate the reductions in muscle, skin and core temperature following exposure to −110°C whole body cryotherapy (WBC), and compare these to 8°C cold water immersion (CWI). Twenty active male subjects were randomly assigned to a 4-min exposure of WBC or CWI. A minimum of 7 days later subjects were exposed to the other treatment. Muscle temperature in the right vastus lateralis (n = 10); thigh skin (average, maximum and minimum) and rectal temperature (n = 10) were recorded before and 60 min after treatment. The greatest reduction (P<0.05) in muscle (mean ± SD; 1 cm: WBC, 1.6±1.2°C; CWI, 2.0±1.0°C; 2 cm: WBC, 1.2±0.7°C; CWI, 1.7±0.9°C; 3 cm: WBC, 1.6±0.6°C; CWI, 1.7±0.5°C) and rectal temperature (WBC, 0.3±0.2°C; CWI, 0.4±0.2°C) were observed 60 min after treatment. The largest reductions in average (WBC, 12.1±1.0°C; CWI, 8.4±0.7°C), minimum (WBC, 13.2±1.4°C; CWI, 8.7±0.7°C) and maximum (WBC, 8.8±2.0°C; CWI, 7.2±1.9°C) skin temperature occurred immediately after both CWI and WBC (P<0.05). Skin temperature was significantly lower (P<0.05) immediately after WBC compared to CWI. The present study demonstrates that a single WBC exposure decreases muscle and core temperature to a similar level of those experienced after CWI. Although both treatments significantly reduced skin temperature, WBC elicited a greater decrease compared to CWI. These data may provide information to clinicians and researchers attempting to optimise WBC and CWI protocols in a clinical or sporting setting. PMID:23139763
Microclimate and development of pressure ulcers and superficial skin changes.
Yusuf, Saldy; Okuwa, Mayumi; Shigeta, Yoshie; Dai, Misako; Iuchi, Terumi; Rahman, Sulaiman; Usman, Awaluddin; Kasim, Sukmawati; Sugama, Junko; Nakatani, Toshio; Sanada, Hiromi
2015-02-01
This study aims to evaluate the microclimate and development of pressure ulcers and superficial skin changes. A prospective cohort study was conducted in an acute care ward in Indonesia. Risk factors for pressure ulcers and superficial skin changes were identified based on the Bergstrom Braden conceptual model. Microclimate data were collected every 3 days for 15 days while the development of pressure ulcers and superficial skin changes was observed every day. Pressure ulcers and superficial skin changes were developed in 20 of the 71 participants. Total mean difference in skin temperature was higher for patients with pressure ulcers and superficial skin changes (0·9 ± 0·6°C) compared with controls (0·6 ± 0·8°C) (P = 0·071). Binary logistic regression predictor values for pressure ulcers and superficial skin changes were 0·111 for type of sheet and 0·347 for Braden Scale results. In conclusion, difference in skin temperature seems to be a predictor for pressure ulcer development and superficial skin changes, while synthetic fibre sheets are able to maintain a beneficial microclimate. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Marcos-Martín, Fernando; González-Ferrero, Luis; Martín-Alcocer, Noelia; Paris-Alemany, Alba; La Touche, Roy
2018-01-17
The purpose of this prospective case series was to observe and describe changes in patients with chronic cervico-craniofacial pain of muscular origin treated with multimodal physiotherapy based on a biobehavioral approach. Nine patients diagnosed with chronic myofascial temporomandibular disorder and neck pain were treated with 6 sessions over the course of 2 weeks including: (1) orthopedic manual physiotherapy (joint mobilizations, neurodynamic mobilization, and dynamic soft tissue mobilizations); (2) therapeutic exercises (motor control and muscular endurance exercises); and (3) patient education. The outcome measures of craniofacial (CF-PDI) and neck disability (NDI), kinesiophobia (TSK-11) and catastrophizing (PCS), and range of cervical and mandibular motion (ROM) and posture were collected at baseline, and at 2 and 14 weeks post-baseline. Compared to baseline, statistically significant (p < 0.01) and clinically meaningful improvements that surpassed the minimal detectable change were observed at 14 weeks in CF-PDI (mean change, 8.11 points; 95% confidence interval (CI): 2.55 to 13.69; d = 1.38), in NDI (mean change, 5 cm; 95% CI: 1.74-8.25; d = 0.98), and in the TSK-11 (mean change, 6.55 cm; 95% CI: 2.79-10.32; d = 1.44). Clinically meaningful improvements in self-reported disability, psychological factors, ROM, and craniocervical posture were observed following a multimodal physiotherapy treatment based on a biobehavioral approach.
Filingeri, Davide; Morris, Nathan B; Jay, Ollie
2017-01-01
What is the central question of this study? Investigations on inhibitory/facilitatory modulation of vision, touch and pain show that conditioning stimuli outside the receptive field of testing stimuli modulate the central processing of visual, touch and painful stimuli. We asked whether contextual modulation also exists in human temperature integration. What is the main finding and its importance? Progressive decreases in whole-body mean skin temperature (the conditioning stimulus) significantly increased local thermosensitivity to skin warming but not cooling (the testing stimuli) in a dose-dependent fashion. In resembling the central mechanisms underlying endogenous analgesia, our findings point to the existence of an endogenous thermosensory system in humans that could modulate local skin thermal sensitivity to facilitate thermal behaviour. Although inhibitory/facilitatory central modulation of vision and pain has been investigated, contextual modulation of skin temperature integration has not been explored. Hence, we tested whether progressive decreases in whole-body mean skin temperature (T sk ; a large conditioning stimulus) alter the magnitude estimation of local warming and cooling stimuli applied to hairy and glabrous skin. On four separate occasions, eight men (27 ± 5 years old) underwent a 30 min whole-body cooling protocol (water-perfused suit; temperature, 5°C), during which a quantitative thermosensory test, consisting of reporting the perceived magnitude of warming and cooling stimuli (±8°C from 30°C baseline) applied to the hand (palm/dorsum) and foot (sole/dorsum), was performed before cooling and every 10 min thereafter. The cooling protocol resulted in large progressive reductions in T sk [10 min, -3.36°C (95% confidence interval -2.62 to -4.10); 20 min, -5.21°C (-4.47 to -5.95); and 30 min, -6.32°C (-5.58 to -7.05); P < 0.001], with minimal changes (∼0.08°C) in rectal temperature. While thermosensitivity to local skin cooling remained unchanged (P = 0.831), sensitivity to skin warming increased significantly at each level of T sk for all skin regions [10 min, +4.9% (-1.1 to +11.0); 20 min, +6.1% (+0.1-12.2); and 30 min, +7.9% (+1.9-13.9); P = 0.009]. Linear regression indicated a 1.2% °C -1 increase in warm thermosensitivity with whole-body skin cooling. Overall, large decreases in T sk significantly facilitated warm but not cold sensory processing of local thermal stimuli, in a dose-dependent fashion. In highlighting a novel feature of human temperature integration, these findings point to the existence of an endogenous thermosensory system that could modulate local skin thermal sensitivity in relationship to whole-body thermal states. © 2016 The Authors. Experimental Physiology © 2016 The Physiological Society.
Imamura, Tetsuya; Ishizuka, Osamu; Sudha, Gautam Silwal; Lei, Zhang; Hosoda, Tomoka; Noguchi, Wataru; Yamagishi, Takahiro; Yokoyama, Hitoshi; Kurizaki, Yoshiki; Nishizawa, Osamu
2013-06-01
We determined if THC-002, a galenical produced from Ba-Wei-Die-Huang-Wan, could increase skin temperature and inhibit detrusor overactivity induced by sudden whole body cooling. Further, we determined if THC-002 could decrease expression of transient receptor potential melastatin 8 (TRPM8) channels associated with the cold responses. Hind leg skin temperature of female 10-week-old Sprague-Dawley rats was measured by thermal imaging. Experimental rats (n = 12) were given oral 100 mg/kg THC-002 daily for one week, and controls (n = 12) were similarly treated with THC-002-free solution. Afterwards, thermal imaging and cystometric investigations of the freely moving conscious rats were performed at room temperature (RT, 27 ± 2°C) for 20 min. The rats were then transferred to a low temperature (LT, 4 ± 2°C) environment during which thermal imaging and cystometric measurements were taken at 5, 10, 20, 30, and 40 min. Afterward, the skin tissues were harvested to estimate expression levels of TRPM8 channels by immunohistochemistry and real-time reverse-transcription polymerase chain reaction. The RT skin temperature of THC-002-treated rats was significantly higher than controls. During the first 20 min under LT, the control rats exhibited cold stress-induced detrusor overactivity such as decreased voiding interval and bladder capacity. THC-002 partially inhibited the detrusor overactivity patterns. During the second 20 min, skin temperature was relatively stable, and the detrusor overactivity of both groups slowly disappeared. THC-002 significantly reduced expression of TRPM8 channel protein and mRNA. THC-002 inhibited cold stress-induced detrusor overactivity resulting from decreasing skin temperature. Therefore, THC-002 might provide resistance to cold stress-exacerbated lower urinary tract symptoms. Copyright © 2012 Wiley Periodicals, Inc.
Methodology for estimation of time-dependent surface heat flux due to cryogen spray cooling.
Tunnell, James W; Torres, Jorge H; Anvari, Bahman
2002-01-01
Cryogen spray cooling (CSC) is an effective technique to protect the epidermis during cutaneous laser therapies. Spraying a cryogen onto the skin surface creates a time-varying heat flux, effectively cooling the skin during and following the cryogen spurt. In previous studies mathematical models were developed to predict the human skin temperature profiles during the cryogen spraying time. However, no studies have accounted for the additional cooling due to residual cryogen left on the skin surface following the spurt termination. We formulate and solve an inverse heat conduction (IHC) problem to predict the time-varying surface heat flux both during and following a cryogen spurt. The IHC formulation uses measured temperature profiles from within a medium to estimate the surface heat flux. We implement a one-dimensional sequential function specification method (SFSM) to estimate the surface heat flux from internal temperatures measured within an in vitro model in response to a cryogen spurt. Solution accuracy and experimental errors are examined using simulated temperature data. Heat flux following spurt termination appears substantial; however, it is less than that during the spraying time. The estimated time-varying heat flux can subsequently be used in forward heat conduction models to estimate temperature profiles in skin during and following a cryogen spurt and predict appropriate timing for onset of the laser pulse.
Sagaidachnyi, A A; Fomin, A V; Usanov, D A; Skripal, A V
2017-02-01
The determination of the relationship between skin blood flow and skin temperature dynamics is the main problem in thermography-based blood flow imaging. Oscillations in skin blood flow are the source of thermal waves propagating from micro-vessels toward the skin's surface, as assumed in this study. This hypothesis allows us to use equations for the attenuation and dispersion of thermal waves for converting the temperature signal into the blood flow signal, and vice versa. We developed a spectral filtering approach (SFA), which is a new technique for thermography-based blood flow imaging. In contrast to other processing techniques, the SFA implies calculations in the spectral domain rather than in the time domain. Therefore, it eliminates the need to solve differential equations. The developed technique was verified within 0.005-0.1 Hz, including the endothelial, neurogenic and myogenic frequency bands of blood flow oscillations. The algorithm for an inverse conversion of the blood flow signal into the skin temperature signal is addressed. The examples of blood flow imaging of hands during cuff occlusion and feet during heating of the back are illustrated. The processing of infrared (IR) thermograms using the SFA allowed us to restore the blood flow signals and achieve correlations of about 0.8 with a waveform of a photoplethysmographic signal. The prospective applications of the thermography-based blood flow imaging technique include non-contact monitoring of the blood supply during engraftment of skin flaps and burns healing, as well the use of contact temperature sensors to monitor low-frequency oscillations of peripheral blood flow.
Intra-articular temperatures of the knee in sports – An in-vivo study of jogging and alpine skiing
Becher, Christoph; Springer, Jan; Feil, Sven; Cerulli, Guiliano; Paessler, Hans H
2008-01-01
Background Up to date, no information exists about the intra-articular temperature changes of the knee related to activity and ambient temperature. Methods In 6 healthy males, a probe for intra-articular measurement was inserted into the notch of the right knee. Each subject was jogging on a treadmill in a closed room at 19°C room temperature and skiing in a ski resort at -3°C outside temperature for 60 minutes. In both conditions, temperatures were measured every fifteen minutes intra-articulary and at the skin surface of the knee. A possible influence on joint function and laxity was evaluated before and after activity. Statistical analysis of intra-articular and skin temperatures was done using nonparametric Wilcoxon's sign rank sum test and Mann-Whitney's-U-Test. Results Median intra-articular temperatures increased from 31.4°C before activity by 2.1°C, 4°C, 5.8°C and 6.1°C after 15, 30, 45 and 60 min of jogging (all p ≤ 0.05). Median intra-articular temperatures dropped from 32.2°C before activity by 0.5°C, 1.9°C, 3.6°C and 1.1°C after 15, 30, 45 and 60 min of skiing (all n.s.). After 60 minutes of skiing (jogging), the median intra-articular temperature was 19.6% (8.7%) higher than the skin surface temperature at the knee. Joint function and laxity appeared not to be different before and after activity within both groups. Conclusion This study demonstrates different changes of intra-articular and skin temperatures during sports in jogging and alpine skiing and suggests that changes are related to activity and ambient temperature. PMID:18405365
Intelligent neonatal monitoring based on a virtual thermal sensor
2014-01-01
Background Temperature measurement is a vital part of daily neonatal care. Accurate measurements are important for detecting deviations from normal values for both optimal incubator and radiant warmer functioning. The purpose of monitoring the temperature is to maintain the infant in a thermoneutral environmental zone. This physiological zone is defined as the narrow range of environmental temperatures in which the infant maintains a normal body temperature without increasing his or her metabolic rate and thus oxygen consumption. Although the temperature measurement gold standard is the skin electrode, infrared thermography (IRT) should be considered as an effortless and reliable tool for measuring and mapping human skin temperature distribution and assist in assessing thermoregulatory reflexes. Methods Body surface temperature was recorded under several clinical conditions using an infrared thermography imaging technique. Temperature distributions were recorded as real-time video, which was analyzed to evaluate mean skin temperatures. Emissivity variations were considered for optimal neonatal IRT correction for which the compensation vector was overlaid on the tracking algorithm to improve the temperature reading. Finally, a tracking algorithm was designed for active follow-up of the defined region of interest over a neonate’s geometry. Results The outcomes obtained from the thermal virtual sensor demonstrate its ability to accurately track different geometric profiles and shapes over the external anatomy of a neonate. Only a small percentage of the motion detection attempts failed to fit tracking scenarios due to the lack of a properly matching matrix for the ROI profile over neonate’s body surface. Conclusions This paper presents the design and implementation of a virtual temperature sensing application that can assist neonatologists in interpreting a neonate’s skin temperature patterns. Regarding the surface temperature, the influence of different environmental conditions inside the incubator has been confirming. PMID:24580961
Intelligent neonatal monitoring based on a virtual thermal sensor.
Abbas, Abbas K; Leonhardt, Steffen
2014-03-02
Temperature measurement is a vital part of daily neonatal care. Accurate measurements are important for detecting deviations from normal values for both optimal incubator and radiant warmer functioning. The purpose of monitoring the temperature is to maintain the infant in a thermoneutral environmental zone. This physiological zone is defined as the narrow range of environmental temperatures in which the infant maintains a normal body temperature without increasing his or her metabolic rate and thus oxygen consumption. Although the temperature measurement gold standard is the skin electrode, infrared thermography (IRT) should be considered as an effortless and reliable tool for measuring and mapping human skin temperature distribution and assist in assessing thermoregulatory reflexes. Body surface temperature was recorded under several clinical conditions using an infrared thermography imaging technique. Temperature distributions were recorded as real-time video, which was analyzed to evaluate mean skin temperatures. Emissivity variations were considered for optimal neonatal IRT correction for which the compensation vector was overlaid on the tracking algorithm to improve the temperature reading. Finally, a tracking algorithm was designed for active follow-up of the defined region of interest over a neonate's geometry. The outcomes obtained from the thermal virtual sensor demonstrate its ability to accurately track different geometric profiles and shapes over the external anatomy of a neonate. Only a small percentage of the motion detection attempts failed to fit tracking scenarios due to the lack of a properly matching matrix for the ROI profile over neonate's body surface. This paper presents the design and implementation of a virtual temperature sensing application that can assist neonatologists in interpreting a neonate's skin temperature patterns. Regarding the surface temperature, the influence of different environmental conditions inside the incubator has been confirming.
... of the body. The skin and its derivatives (hair, nails, sweat and oil glands) make up the integumentary system. One of the main functions of the skin is protection. It protects the body from external factors such as bacteria, chemicals, and temperature.
Ultrathin conformal devices for precise and continuous thermal characterization of human skin
Webb, R. Chad; Bonifas, Andrew P.; Behnaz, Alex; Zhang, Yihui; Yu, Ki Jun; Cheng, Huanyu; Shi, Mingxing; Bian, Zuguang; Liu, Zhuangjian; Kim, Yun-Soung; Yeo, Woon-Hong; Park, Jae Suk; Song, Jizhou; Li, Yuhang; Huang, Yonggang; Gorbach, Alexander M.; Rogers, John A.
2013-01-01
Precision thermometry of the skin can, together with other measurements, provide clinically relevant information about cardiovascular health, cognitive state, malignancy and many other important aspects of human physiology. Here, we introduce an ultrathin, compliant skin-like sensor/actuator technology that can pliably laminate onto the epidermis to provide continuous, accurate thermal characterizations that are unavailable with other methods. Examples include non-invasive spatial mapping of skin temperature with millikelvin precision, and simultaneous quantitative assessment of tissue thermal conductivity. Such devices can also be implemented in ways that reveal the time-dynamic influence of blood flow and perfusion on these properties. Experimental and theoretical studies establish the underlying principles of operation, and define engineering guidelines for device design. Evaluation of subtle variations in skin temperature associated with mental activity, physical stimulation and vasoconstriction/dilation along with accurate determination of skin hydration through measurements of thermal conductivity represent some important operational examples. PMID:24037122
NASA Astrophysics Data System (ADS)
Li, He; Cui, Yun
2017-12-01
Nowadays, flexible electronic devices are increasingly used in direct contact with human skin to monitor the real-time health of human body. Based on the Fourier heat conduction equation and Pennes bio-heat transfer equation, this paper deduces the analytical solutions of one - dimensional heat transfer for flexible electronic devices integrated with human skin under the condition of a constant power. The influence of contact thermal resistance between devices and skin is considered as well. The corresponding finite element model is established to verify the correctness of analytical solutions. The results show that the finite element analysis agrees well with the analytical solution. With bigger thermal resistance, temperature increase of skin surface will decrease. This result can provide guidance for the design of flexible electronic devices to reduce the negative impact that exceeding temperature leave on human skin.
Ultrathin conformal devices for precise and continuous thermal characterization of human skin
NASA Astrophysics Data System (ADS)
Webb, R. Chad; Bonifas, Andrew P.; Behnaz, Alex; Zhang, Yihui; Yu, Ki Jun; Cheng, Huanyu; Shi, Mingxing; Bian, Zuguang; Liu, Zhuangjian; Kim, Yun-Soung; Yeo, Woon-Hong; Park, Jae Suk; Song, Jizhou; Li, Yuhang; Huang, Yonggang; Gorbach, Alexander M.; Rogers, John A.
2013-10-01
Precision thermometry of the skin can, together with other measurements, provide clinically relevant information about cardiovascular health, cognitive state, malignancy and many other important aspects of human physiology. Here, we introduce an ultrathin, compliant skin-like sensor/actuator technology that can pliably laminate onto the epidermis to provide continuous, accurate thermal characterizations that are unavailable with other methods. Examples include non-invasive spatial mapping of skin temperature with millikelvin precision, and simultaneous quantitative assessment of tissue thermal conductivity. Such devices can also be implemented in ways that reveal the time-dynamic influence of blood flow and perfusion on these properties. Experimental and theoretical studies establish the underlying principles of operation, and define engineering guidelines for device design. Evaluation of subtle variations in skin temperature associated with mental activity, physical stimulation and vasoconstriction/dilation along with accurate determination of skin hydration through measurements of thermal conductivity represent some important operational examples.
Gefen, Amit
2011-08-01
In this study, a mathematical model is developed for analyzing the effects of the microclimate on skin tolerance to superficial pressure ulcers (SPUs). The modeling identified the following factors as such that decrease the tolerance of skin to SPUs: (i) increase in the skin temperature, (ii) increase in the ambient temperature, (iii) increase in the relative humidity, (iv) increase in the skin-support (or skin-clothing-support) contact pressures, and (v) decrease in permeabilities of the materials contacting the skin or being close to it, e.g. the covering sheet of the support and clothing. The modeling is consistent with relevant empirical findings and clinical observations documented in the literature, explains them from a basic science aspect, and can be further developed for design of interventions, safer patient clothing and supports that consider the optimization of microclimate factors. Copyright © 2010 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.
Nonextensive statistics and skin depth of transverse wave in collisional plasma
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hashemzadeh, M., E-mail: hashemzade@gmail.com
Skin depth of transverse wave in a collisional plasma is studied taking into account the nonextensive electron distribution function. Considering the kinetic theory for charge particles and using the Bhatnagar-Gross-Krook collision model, a generalized transverse dielectric permittivity is obtained. The transverse dispersion relation in different frequency ranges is investigated. Obtaining the imaginary part of the wave vector from the dispersion relation, the skin depth for these frequency ranges is also achieved. Profiles of the skin depth show that by increasing the q parameter, the penetration depth decreases. In addition, the skin depth increases by increasing the electron temperature. Finally, itmore » is found that in the high frequency range and high electron temperature, the penetration depth decreases by increasing the collision frequency. In contrast, by increasing the collision frequency in a highly collisional frequency range, the skin depth of transverse wave increases.« less
NASA Astrophysics Data System (ADS)
Gomez-Tames, Jose; Sugiyama, Yukiya; Laakso, Ilkka; Tanaka, Satoshi; Koyama, Soichiro; Sadato, Norihiro; Hirata, Akimasa
2016-12-01
Transcranial direct current stimulation (tDCS) is a neuromodulation scheme where a small current is delivered to the brain via two electrodes attached to the scalp. The electrode design is an important topic, not only as regards efficacy, but also from a safety perspective, as tDCS may be related to skin lesions that are sometimes observed after stimulation. Previous computational models of tDCS have omitted the effects of microscopic structures in the skin, and the different soak conditions of the electrodes, and model validation has been limited. In this study, multiphysics and multiscale analysis are proposed to demonstrate the importance of microscopic modeling of the skin, in order to clarify the effects of the internal electric field, and to examine temperature elevation around the electrodes. This novel microscopic model of the skin layer took into consideration the effect of saline/water penetration in hair follicles and sweat ducts on the field distribution around the electrodes. The temperature elevation in the skin was then computed by solving the bioheat equation. Also, a multiscale model was introduced to account for macroscopic and microscopic tissues of the head and skin, which was validated by measurement of the head resistance during tDCS. As a result, the electric field in the microscopic model of the skin was less localized when the follicles/ducts were filled with saline instead of hair or tap water. Temperature elevation was also lessened with saline, in comparison with other substances. Saline, which may penetrate the hair follicles and sweat ducts, suppressed the field concentration around the electrodes. For conventional magnitudes of current injection, and a head resistance of less than 10 kΩ, the temperature elevation in the skin when using saline-soaked electrodes was low, less than 0.1 °C, and unlikely to cause adverse thermal effects.
Effects of hypobaric pressure on human skin: implications for cryogen spray cooling (part II).
Aguilar, Guillermo; Franco, Walfre; Liu, Jie; Svaasand, Lars O; Nelson, J Stuart
2005-02-01
Clinical results have demonstrated that dark purple port wine stain (PWS) birthmarks respond favorably to laser induced photothermolysis after the first three to five treatments. Nevertheless, complete blanching is rarely achieved and the lesions stabilize at a red-pink color. In a feasibility study (Part I), we showed that local hypobaric pressure on PWS human skin prior to laser irradiation induced significant lesion blanching. The objective of the present study (Part II) is to investigate the effects of hypobaric pressures on the efficiency of cryogen spray cooling (CSC), a technique that assists laser therapy of PWS and other dermatoses. Experiments were carried out within a suction cup and vacuum chamber to study the effect of hypobaric pressure on the: (1) interaction of cryogen sprays with human skin; (2) spray atomization; and (3) thermal response of a model skin phantom. A high-speed camera was used to acquire digital images of spray impingement on in vivo human skin and spray cones generated at different hypobaric pressures. Subsequently, liquid cryogen was sprayed onto a skin phantom at atmospheric and 17, 34, 51, and 68 kPa (5, 10, 15, and 20 in Hg) hypobaric pressures. A fast-response temperature sensor measured sub-surface phantom temperature as a function of time. Measurements were used to solve an inverse heat conduction problem to calculate surface temperatures, heat flux, and overall heat extraction at the skin phantom surface. Under hypobaric pressures, cryogen spurts did not produce skin indentation and only minimal frost formation. Sprays also showed shorter jet lengths and better atomization. Lower minimum surface temperatures and higher overall heat extraction from skin phantoms were reached. The combined effects of hypobaric pressure result in more efficient cryogen evaporation that enhances heat extraction and, therefore, improves the epidermal protection provided by CSC. (c) 2005 Wiley-Liss, Inc.
Roustit, Matthieu; Hellmann, Marcin; Cracowski, Claire; Blaise, Sophie; Cracowski, Jean-Luc
2012-01-01
Digital skin vasoconstriction on local cooling is exaggerated in primary Raynaud’s phenomenon (RP) compared to controls. A significant part of such vasoconstriction relies on the nitric oxide (NO) pathway inhibition. We tested the effect of PDE5 inhibitor sildenafil, which potentiates the effect of NO, on skin blood flow. We recruited 15 patients with primary RP, performing local cooling without sildenafil (day 1), after a single 50 mg oral dose (day 2), and 100 mg (day 3). Skin blood flow, skin temperature and arterial pressure were recorded, and data were expressed as cutaneous vascular conductance (CVC). Sildenafil at 100 mg, but not 50 mg, significantly lessened the cooling-induced decrease in CVC. It also increased resting CVC and skin temperature. These data suggest that 100 mg sildenafil improves digital skin blood flow to local cooling in primary RP. The benefit of sildenafil “as required” should be confirmed in a randomized controlled trial. PMID:22453196
Incubator temperature control: effects on the very low birthweight infant.
Ducker, D A; Lyon, A J; Ross Russell, R; Bass, C A; McIntosh, N
1985-01-01
We studied temperature stability in 22 infants of birthweight less than 1500 g in the first four days of life. Infants were nursed in incubators using either air mode control or skin temperature servo control. Data were collected continuously using a computer linked monitoring system. Skin temperature control resulted in a less stable thermal environment than air mode control. Increased thermal stability in the incubator on air mode control may well be beneficial, particularly to sick, very low birthweight infants. PMID:4062342
Bishop, Mark D.; Fritz, Julie M.; Robinson, Michael E.; Asal, Nabih R.; Nisenzon, Anne N.
2013-01-01
Background Psychologically informed practice emphasizes routine identification of modifiable psychological risk factors being highlighted. Objective The purpose of this study was to test the predictive validity of the STarT Back Screening Tool (SBT) in comparison with single-construct psychological measures for 6-month clinical outcomes. Design This was an observational, prospective cohort study. Methods Patients (n=146) receiving physical therapy for low back pain were administered the SBT and a battery of psychological measures (Fear-Avoidance Beliefs Questionnaire physical activity scale and work scale [FABQ-PA and FABQ-W, respectively], Pain Catastrophizing Scale [PCS], 11-item version of the Tampa Scale of Kinesiophobia [TSK-11], and 9-item Patient Health Questionnaire [PHQ-9]) at initial evaluation and 4 weeks later. Treatment was at the physical therapist's discretion. Clinical outcomes consisted of pain intensity and self-reported disability. Prediction of 6-month clinical outcomes was assessed for intake SBT and psychological measure scores using multiple regression models while controlling for other prognostic variables. In addition, the predictive capabilities of intake to 4-week changes in SBT and psychological measure scores for 6-month clinical outcomes were assessed. Results Intake pain intensity scores (β=.39 to .45) and disability scores (β=.47 to .60) were the strongest predictors in all final regression models, explaining 22% and 24% and 43% and 48% of the variance for the respective clinical outcome at 6 months. Neither SBT nor psychological measure scores improved prediction of 6-month pain intensity. The SBT overall scores (β=.22) and SBT psychosocial scores (β=.25) added to the prediction of disability at 6 months. Four-week changes in TSK-11 scores (β=−.18) were predictive of pain intensity at 6 months. Four-week changes in FABQ-PA scores (β=−.21), TSK-11 scores (β=−.20) and SBT overall scores (β=−.18) were predictive of disability at 6 months. Limitations Physical therapy treatment was not standardized or accounted for in the analysis. Conclusions Prediction of clinical outcomes by psychology-based measures was dependent upon the clinical outcome domain of interest. Similar to studies from the primary care setting, initial screening with the SBT provided additional prognostic information for 6-month disability and changes in SBT overall scores may provide important clinical decision-making information for treatment monitoring. PMID:23125279
Lentz, Trevor A; Zeppieri, Giorgio; George, Steven Z; Tillman, Susan M; Moser, Michael W; Farmer, Kevin W; Chmielewski, Terese L
2015-02-01
Fear of reinjury and lack of confidence influence return-to-sport outcomes after anterior cruciate ligament (ACL) reconstruction. The physical, psychosocial, and functional recovery of patients reporting fear of reinjury or lack of confidence as their primary barrier to resuming sports participation is unknown. To compare physical impairment, functional, and psychosocial measures between subgroups based on return-to-sport status and fear of reinjury/lack of confidence in the return-to-sport stage and to determine the association of physical impairment and psychosocial measures with function for each subgroup at 6 months and 1 year after surgery. Case-control study; Level of evidence, 3. Physical impairment (quadriceps index [QI], quadriceps strength/body weight [QSBW], hamstring:quadriceps strength ratio [HQ ratio], pain intensity), self-report of function (International Knee Documentation Committee [IKDC]), and psychosocial (Tampa Scale for Kinesiophobia-shortened form [TSK-11]) measures were collected at 6 months and 1 year after surgery in 73 patients with ACL reconstruction. At 1 year, subjects were divided into "return-to-sport" (YRTS) or "not return-to-sport" (NRTS) subgroups based on their self-reported return to preinjury sport status. Patients in the NRTS subgroup were subcategorized as NRTS-Fear/Confidence if fear of reinjury/lack of confidence was the primary reason for not returning to sports, and all others were categorized as NRTS-Other. A total of 46 subjects were assigned to YRTS, 13 to NRTS-Other, and 14 to NRTS-Fear/Confidence. Compared with the YRTS subgroup, the NRTS-Fear/Confidence subgroup was older and had lower QSBW, lower IKDC score, and higher TSK-11 score at 6 months and 1 year; however, they had similar pain levels. In the NRTS-Fear/Confidence subgroup, the IKDC score was associated with QSBW and pain at 6 months and QSBW, QI, pain, and TSK-11 scores at 1 year. Elevated pain-related fear of movement/reinjury, quadriceps weakness, and reduced IKDC score distinguish patients who are unable to return to preinjury sports participation because of fear of reinjury/lack of confidence. Despite low average pain ratings, fear of pain may influence function in this subgroup. Assessment of fear of reinjury, quadriceps strength, and self-reported function at 6 months may help identify patients at risk for not returning to sports at 1 year and should be considered for inclusion in return-to-sport guidelines. © 2014 The Author(s).
Body temperature and resistance to evaporative water loss in tropical Australian frogs.
Tracy, Christopher R; Christian, Keith A; Betts, Gregory; Tracy, C Richard
2008-06-01
Although the skin of most amphibians measured to date offers no resistance to evaporative water loss (EWL), some species, primarily arboreal frogs, produce skin secretions that increase resistance to EWL. At high air temperatures, it may be advantageous for amphibians to increase EWL as a means to decrease body temperature. In Australian hylid frogs, most species do not decrease their resistance at high air temperature, but some species with moderate resistance (at moderate air temperatures) gradually decrease resistance with increasing air temperature, and some species with high resistance (at moderate air temperatures) abruptly decrease resistance at high air temperatures. Lower skin resistance at high air temperatures decreases the time to desiccation, but the lower body temperatures allow the species to avoid their critical thermal maximum (CT(Max)) body temperatures. The body temperatures of species with low to moderate resistances to EWL that do not adjust resistance at high air temperatures do not warm to their CT(Max), although for some species, this is because they have high CT(Max) values. As has been reported previously for resistance to EWL generally, the response pattern of change of EWL at high air temperatures has apparently evolved independently among Australian hylids. The mechanisms involved in causing resistance and changes in resistance are unknown.
Correlation of Wissler Human Thermal Model Blood Flow and Shiver Algorithms
NASA Technical Reports Server (NTRS)
Bue, Grant; Makinen, Janice; Cognata, Thomas
2010-01-01
The Wissler Human Thermal Model (WHTM) is a thermal math model of the human body that has been widely used to predict the human thermoregulatory response to a variety of cold and hot environments. The model has been shown to predict core temperature and skin temperatures higher and lower, respectively, than in tests of subjects in crew escape suit working in a controlled hot environments. Conversely the model predicts core temperature and skin temperatures lower and higher, respectively, than in tests of lightly clad subjects immersed in cold water conditions. The blood flow algorithms of the model has been investigated to allow for more and less flow, respectively, for the cold and hot case. These changes in the model have yielded better correlation of skin and core temperatures in the cold and hot cases. The algorithm for onset of shiver did not need to be modified to achieve good agreement in cold immersion simulations
NASA Astrophysics Data System (ADS)
Shreve, Cheney
2010-12-01
With more than sixty free and publicly available high-quality datasets, including ecosystem variables, radiation budget variables, and land cover products, the MODIS instrument and the MODIS scientific team have contributed significantly to scientific investigations of ecosystems across the globe. The MODIS instrument, launched in December 1999, has 36 spectral bands, a viewing swath of 2330 km, and acquires data at 250 m, 500 m, and 1000 m spatial resolution every one to two days. Radiation budget variables include surface reflectance, skin temperature, emissivity, and albedo, to list a few. Ecosystem variables include several vegetation indices and productivity measures. Land cover characteristics encompass land cover classifications as well as model parameters and vegetation classifications. Many of these products are instrumental in constraining global climate models and climate change studies, as well as monitoring events such as the recent flooding in Pakistan, the unprecedented oil spill in the Gulf of Mexico, or phytoplankton bloom in the Barents Sea. While product validation efforts by the MODIS scientific team are both vigorous and continually improving, validation is unquestionably one of the most difficult tasks when dealing with remotely derived datasets, especially at the global scale. The quality and availability of MODIS data have led to widespread usage in the scientific community that has further contributed to validation and development of the MODIS products. In their recent paper entitled 'Land surface skin temperature climatology: benefitting from the strengths of satellite observations', Jin and Dickinson review the scientific theory behind, and demonstrate application of, a MODIS temperature product: surface skin temperature. Utilizing datasets from the Global Historical Climatological Network (GHCN), daily skin and air temperature from the Atmospheric Radiation Measurement (ARM) program, and MODIS products (skin temperature, albedo, land cover, water vapor, cloud cover), they show that skin temperature is clearly a different physical parameter from air temperature and varies from air temperature in magnitude, response to atmospheric conditions, and diurnal phase. Although the accuracy of skin temperature (Tskin) algorithms has improved to within 0.5-1°C for field measurements and clear-sky satellite observations (Becker and Li 1995, Goetz et al 1995, Wan and Dozier 1996), general confusion regarding the physical definition of 'surface temperature' and how it can be used for climate studies has persisted throughout the scientific community and limited the applications of these data (Jin and Dickinson 2010). For example, satellite sea surface temperature was used as evidence of global climate change instead of skin temperature in the IPCC 2001 and 2007 reports (Jin and Dickinson 2010). This work provides clarity in the theoretical definition of temperature variables, demonstrates the difference between air and skin temperature, and aids the understanding of the MODIS Tskin product, which could be very beneficial for future climate studies. As outlined by Jin and Dickinson, 'surface temperature' is a vague term commonly used in reference to air temperature, aerodynamic temperature, and skin temperature. Air temperature (Tair), or thermodynamic temperature, is measured by an in situ instrument usually 1.5-2 m above the ground. Aerodynamic temperature (Taero) refers to the temperature at the height of the roughness length of heat. Satellite derived skin temperature (Tskin) is the radiometric temperature derived from the inverse of Planck's function. While these different temperature variables are typically correlated, they differ as a result of environmental conditions (e.g. land cover and sky conditions; Jin and Dickinson 2010). With an extensive network of Tair measurements, some have questioned the benefits of using Tskin at all (Peterson et al 1997, 1998). Tskin and Tair can vary depending on land cover or sky conditions and variations may be large, e.g., for sparsely vegetated areas where net radiation is largely balanced by sensible heat flux (Hall et al 1992, Sun and Mahrt 1995, Jin et al 1997). Tskin can be higher than Taero at midday and lower at night (Sun and Mahrt 1995) and some models use Taero to approximate surface radiative temperature (Hubband and Monteith 1986). One of the strengths of the MODIS instrument is the simultaneous collection of surface and atmospheric conditions. By incorporating a range of MODIS variables in their comparison to Tskin, the authors examine the relationship of Tskin to atmospheric and surface conditions. Results from their global evaluation of Tskin highlight its variability on an inter-annual basis, its variation with solar zenith angle, and diurnal variations, which are not achievable with Tair measurements. Comparison with land cover type illustrates the seasonality of Tskin for different land covers. Comparison with the enhanced vegetation index (EVI) suggests more vegetation reduces skin temperature. Using the MODIS albedo, they demonstrate a clear relationship between yearly averaged Tskin and land surface albedo. Lastly, their examination of water vapor and cloud cover in comparison to Tskin suggests similar seasonality between these two variables. The MODIS Tskin product is not without uncertainty; retrieving Tskin requires a calculation of radiative transfer to account for atmospheric emission and molecular absorption, which is time and resource intensive (Jin and Dickinson 2010). Additionally, surface emissivity, instrument noise, and view angle geometry contribute to error in Tskin estimations (Jin and Dickinson 2010). The transparency of the scientific theory underlying this work, and the clear demonstration of the distinction between temperature measures on varying scales, demonstrates the usefulness of Tskin despite the uncertainties. Perhaps equally as important is the tone; in a time when the controversy surrounding climate change is peaking and the very ethics of the scientific community are being questioned, it is more critical than ever to be transparent in one's work and to assist the scientific community in understanding the tools we have available to us for investigating climate change. References Becker F and Li Z-L 1995 Surface temperature and emissivity at different scales: definition, measurement and related problems Remote Sensing Rev. 12 225-53 Goetz S J, Halthore R, Hall F G and Markham B L 1995 Surface temperature retrieval in a temperate grassland with multi-resolution sensors J. Geophys. Res. Atmos. 100 25397-410 Hall F G, Huemmrich K F, Goetz P J, Sellers P J and Nickeson J E 1992 Satellite remote sensing of the surface energy balance: success, failures and unresolved issues in FIFE J. Geophys. Res. Atmos. 97 19061-90 Jin M and Dickinson R E 2010 Land surface skin temperature climatology: benefitting from the strengths of satellite observations Environ. Res. Lett. 5 044004 Jin M, Dickinson R E and Vogelmann A M 1997 A comparison of CCM2/BATS skin temperature and surface-air temperature with satellite and surface observations J. Climate 10 1505-24 Hubband N D S and Monteith J L 1986 Radiative surface temperature and energy balance of a wheat canopy Boundary Layer Meteorol. 36 107-16 Peterson T C and Vose R S 1997 An overview of the Global Historical Climatology Network temperature data base Bull. Am. Meteorol. Soc. 78 2837-49 Peterson T C, Karl T R, Jamason P F, Knight R and Easterling D R 1998 The first difference method: maximizing station density for the calculation of long-term global temperature change J. Geophys. Res. Atmos. 103 25967-74 Sun J and Mahrt L 1995 Determination of surface fluxes from the surface radiative temperature Atmos. Sci. 52 1096-106 Wan Z and Dozier J 1996 A generalized split-window algorithm for retrieving land-surface temperature from space IEEE Trans. Geosci. Remote Sensing 34 892-905
Zherebtsov, Evgeny A; Zherebtsova, Angelina I; Doronin, Alexander; Dunaev, Andrey V; Podmasteryev, Konstantin V; Bykov, Alexander; Meglinski, Igor
2017-04-01
We introduce a noninvasive diagnostic approach for functional monitoring of blood microflows in capillaries and thermoregulatory vessels within the skin. The measuring system is based on the combined use of laser Doppler flowmetry and skin contact thermometry. The obtained results suggest that monitoring of blood microcirculation during the occlusion, performed in conjunction with the skin temperature measurements in the thermally stabilized medium, has a great potential for quantitative assessment of angiospatic dysfunctions of the peripheral blood vessels. The indices of blood flow reserve and temperature response were measured and used as the primarily parameters of the functional diagnostics of the peripheral vessels of skin. Utilizing these parameters, a simple phenomenological model has been suggested to identify patients with angiospastic violations in the vascular system.
NASA Astrophysics Data System (ADS)
Zherebtsov, Evgeny A.; Zherebtsova, Angelina I.; Doronin, Alexander; Dunaev, Andrey V.; Podmasteryev, Konstantin V.; Bykov, Alexander; Meglinski, Igor
2017-04-01
We introduce a noninvasive diagnostic approach for functional monitoring of blood microflows in capillaries and thermoregulatory vessels within the skin. The measuring system is based on the combined use of laser Doppler flowmetry and skin contact thermometry. The obtained results suggest that monitoring of blood microcirculation during the occlusion, performed in conjunction with the skin temperature measurements in the thermally stabilized medium, has a great potential for quantitative assessment of angiospatic dysfunctions of the peripheral blood vessels. The indices of blood flow reserve and temperature response were measured and used as the primarily parameters of the functional diagnostics of the peripheral vessels of skin. Utilizing these parameters, a simple phenomenological model has been suggested to identify patients with angiospastic violations in the vascular system.
Ghoseiri, Kamiar; Zheng, Yong Ping; Leung, Aaron K L; Rahgozar, Mehdi; Aminian, Gholamreza; Masoumi, Mehdi; Safari, Mohammad Reza
2018-01-01
The snug fit of a prosthetic socket over the residual limb can disturb thermal balance and put skin integrity in jeopardy by providing an unpleasant and infectious environment. The prototype of a temperature measurement and control (TM&C) system was previously introduced to resolve thermal problems related to prostheses. This study evaluates its clinical application in a setting with reversal, single subject design. The TM&C system was installed on a fabricated prosthetic socket of a man with unilateral transtibial amputation. Skin temperature of the residual limb without prosthesis at baseline and with prosthesis during rest and walking was evaluated. The thermal sense and thermal comfort of the participant were also evaluated. The results showed different skin temperature around the residual limb with a temperature decrease tendency from proximal to distal. The TM&C system decreased skin temperature rise after prosthesis wearing. The same situation occurred during walking, but the thermal power of the TM&C system was insufficient to overcome heat build-up in some regions of the residual limb. The participant reported no significant change of thermal sense and thermal comfort. Further investigations are warranted to examine thermography pattern of the residual limb, thermal sense, and thermal comfort in people with amputation.
Wu, Zhibin; Li, Nianping; Cui, Haijiao; Peng, Jinqing; Chen, Haowen; Liu, Penglong
2017-01-01
Existing thermal comfort field studies are mainly focused on the relationship between the indoor physical environment and the thermal comfort. In numerous chamber experiments, physiological parameters were adopted to assess thermal comfort, but the experiments’ conclusions may not represent a realistic thermal environment due to the highly controlled thermal environment and few occupants. This paper focuses on determining the relationships between upper extremity skin temperatures (i.e., finger, wrist, hand and forearm) and the indoor thermal comfort. Also, the applicability of predicting thermal comfort by using upper extremity skin temperatures was explored. Field studies were performed in office buildings equipped with split air-conditioning (SAC) located in the hot summer and cold winter (HSCW) climate zone of China during the summer of 2016. Psychological responses of occupants were recorded and physical and physiological factors were measured simultaneously. Standard effective temperature (SET*) was used to incorporate the effect of humidity and air velocity on thermal comfort. The results indicate that upper extremity skin temperatures are good indicators for predicting thermal sensation, and could be used to assess the thermal comfort in terms of physiological mechanism. In addition, the neutral temperature was 24.7 °C and the upper limit for 80% acceptability was 28.2 °C in SET*. PMID:28934173
Wu, Zhibin; Li, Nianping; Cui, Haijiao; Peng, Jinqing; Chen, Haowen; Liu, Penglong
2017-09-21
Existing thermal comfort field studies are mainly focused on the relationship between the indoor physical environment and the thermal comfort. In numerous chamber experiments, physiological parameters were adopted to assess thermal comfort, but the experiments' conclusions may not represent a realistic thermal environment due to the highly controlled thermal environment and few occupants. This paper focuses on determining the relationships between upper extremity skin temperatures (i.e., finger, wrist, hand and forearm) and the indoor thermal comfort. Also, the applicability of predicting thermal comfort by using upper extremity skin temperatures was explored. Field studies were performed in office buildings equipped with split air-conditioning (SAC) located in the hot summer and cold winter (HSCW) climate zone of China during the summer of 2016. Psychological responses of occupants were recorded and physical and physiological factors were measured simultaneously. Standard effective temperature (SET*) was used to incorporate the effect of humidity and air velocity on thermal comfort. The results indicate that upper extremity skin temperatures are good indicators for predicting thermal sensation, and could be used to assess the thermal comfort in terms of physiological mechanism. In addition, the neutral temperature was 24.7 °C and the upper limit for 80% acceptability was 28.2 °C in SET*.
Influence of cooling face masks on nasal air conditioning and nasal geometry.
Lindemann, J; Hoffmann, T; Koehl, A; Walz, E M; Sommer, F
2017-06-01
Nasal geometries and temperature of the nasal mucosa are the primary factors affecting nasal air conditioning. Data on intranasal air conditioning after provoking the trigeminal nerve with a cold stimulus simulating the effects of an arctic condition is still missing. The objective was to investigate the influence of skin cooling face masks on nasal air conditioning, mucosal temperature and nasal geometry. Standardized in vivo measurements of intranasal air temperature, humidity and mucosal temperature were performed in 55 healthy subjects at defined detection sites before and after wearing a cooling face mask. Measurements of skin temperature, rhinomanometry and acoustic rhinometry were accomplished. After wearing the face mask the facial skin temperature was significantly reduced. Intranasal air temperature did not change. Absolute humidity and mucosal temperature increased significantly. The acoustic rhinometric results showed a significant increase of the volumes and the cross-sectional areas. There was no change in nasal airflow. Nasal mucosal temperature, humidity of inhaled air, and volume of the anterior nose increased after application of a cold face mask. The response is mediated by the trigeminal nerve. Increased mucosal temperatures as well as changes in nasal geometries seem to guarantee sufficient steady intranasal nasal air conditioning.
Elevated-Temperature Tests Under Static and Aerodynamic Conditions on Honeycomb-Core Sandwich Panels
NASA Technical Reports Server (NTRS)
Groen, Joseph M.; Johnson, Aldie E., Jr.
1959-01-01
Stainless-steel honeycomb-core sandwich panels which differed primarily in skin thicknesses were tested at elevated temperatures under static and aerodynamic conditions. The results of these tests were evaluated to determine the insulating effectiveness and structural integrity of the panels. The static radiant-heating tests were performed in front of a quartz-tube radiant heater at panel skin temperatures up to 1,5000 F. The aerodynamic tests were made in a Mach 1.4 heated blowdown wind tunnel. The tunnel temperature was augmented by additional heat supplied by a radiant heater which raised the panel surface temperature above 8000 F during air flow. Static radiant-heating tests of 2 minutes duration showed that all the panels protected the load-carrying structure about equally well. Thin-skin panels showed an advantage for this short-time test over thick-skin panels from a standpoint of weight against insulation. Permanent inelastic strains in the form of local buckles over each cell of the honeycomb core caused an increase in surface roughness. During the aero- dynamic tests all of the panels survived with little or no damage, and panel flutter did not occur.
NASA Technical Reports Server (NTRS)
Jenkins, J. M.
1979-01-01
Additional information was added to a growing data base from which estimates of finite element model complexities can be made with respect to thermal stress analysis. The manner in which temperatures were smeared to the finite element grid points was examined from the point of view of the impact on thermal stress calculations. The general comparison of calculated and measured thermal stresses is guite good and there is little doubt that the finite element approach provided by NASTRAN results in correct thermal stress calculations. Discrepancies did exist between measured and calculated values in the skin and the skin/frame junctures. The problems with predicting skin thermal stress were attributed to inadequate temperature inputs to the structural model rather than modeling insufficiencies. The discrepancies occurring at the skin/frame juncture were most likely due to insufficient modeling elements rather than temperature problems.
Wolf, M B; Garner, R P
1997-01-01
A model was developed of transient changes in metabolic heat production and core temperature for humans subjected to cold conditions. It was modified to predict thermal effects of the upper parts of the body being sprayed with water from a system designed to reduce the smoke effects of an airplane fire. Temperature changes were computed at 25 body segments in response to water immersion, cold-air exposure, and windy conditions. Inputs to the temperature controller were: (a) temperature change signals from skin segments and (b) an integrated signal of the product of skin and head-core (hypothalamic) temperature changes. The controller stimulated changes in blood flow to skin and muscle and heat production by shivering. Two controller parameters were adjusted to obtain good predictions of temperature and heat-production experimental data in head-out, water-immersion (0 degree-28 degrees C) studies in humans. A water layer on the skin whose thickness decreased transiently due to evaporation was added to describe the effects of the water-spray system. Because the layer evaporated rapidly in a very cold and windy environment, its additional cooling effect over a 60-min exposure period was minimal. The largest additional decrease in rectal temperature due to the water layer was < 1 degree C, which was in normal conditions where total decreases were small.
Hibst, Raimund; Saal, David; Russ, Detlef; Kunzi-Rapp, Karin; Kienle, Alwin; Stock, Karl
2010-01-01
Modern operating microscopes offer high power illumination to ensure optimal visualization, but can also cause thermal damage. The aim of our study is to quantify the thermal effects in vivo and discuss conditions for safe use. In a pilot study on volunteers, we measured the temperature at the skin surface during microscope illumination, including the influence of anaesthesia and the effects of staining, draping, or moistening of the skin. Irradiation within the limit given by safety regulations (200 mW/cm(2)) results in skin surface temperature of 43 degrees C. Higher intensities (forearm 335 mW/cm(2), back 250 mW/cm(2)) are tolerated, resulting in reversible hyperaemia. At a very high illumination intensity (750 mW/cm(2)), pain occurs within 30 s at temperatures of 46 degrees C+/-1 degrees C (hand and forearm), and 43 degrees C+/-2 degrees C (back), respectively. Anaesthesia has no distinct effect on the temperature, whereas staining and drapes result in much higher temperatures (>100 degrees C). Moistening at practicable flow rates can reduce temperature efficiently when combined with a light absorbing and water absorbent drape. In conclusion, surgeons must be aware that surgical microscope illumination without protective means can cause skin temperatures to rise much above pain threshold, which in our study serves as a (conservative) benchmark for potential damage.
NASA Astrophysics Data System (ADS)
Hibst, Raimund; Saal, David; Russ, Detlef; Kunzi-Rapp, Karin; Kienle, Alwin; Stock, Karl
2010-07-01
Modern operating microscopes offer high power illumination to ensure optimal visualization, but can also cause thermal damage. The aim of our study is to quantify the thermal effects in vivo and discuss conditions for safe use. In a pilot study on volunteers, we measured the temperature at the skin surface during microscope illumination, including the influence of anaesthesia and the effects of staining, draping, or moistening of the skin. Irradiation within the limit given by safety regulations (200 mW/cm2) results in skin surface temperature of 43 °C. Higher intensities (forearm 335 mW/cm2, back 250 mW/cm2) are tolerated, resulting in reversible hyperaemia. At a very high illumination intensity (750 mW/cm2), pain occurs within 30 s at temperatures of 46 °C+/-1 °C (hand and forearm), and 43 °C+/-2 °C (back), respectively. Anaesthesia has no distinct effect on the temperature, whereas staining and drapes result in much higher temperatures (>100 °C). Moistening at practicable flow rates can reduce temperature efficiently when combined with a light absorbing and water absorbent drape. In conclusion, surgeons must be aware that surgical microscope illumination without protective means can cause skin temperatures to rise much above pain threshold, which in our study serves as a (conservative) benchmark for potential damage.
Regional differences in sweat rate response of steers to short-term heat stress
NASA Astrophysics Data System (ADS)
Scharf, B.; Wax, L. E.; Aiken, G. E.; Spiers, D. E.
2008-11-01
Six Angus steers (319 ± 8.5 kg) were assigned to one of two groups (hot or cold exposure) of three steers each, and placed into two environmental chambers initially maintained at 16.5-18.8°C air temperature ( T a). Cold chamber T a was lowered to 8.4°C, while T a within the hot chamber was increased to 32.7°C over a 24-h time period. Measurements included respiration rate, and air and body (rectal and skin) temperatures. Skin temperature was measured at shoulder and rump locations, with determination of sweat rate using a calibrated moisture sensor. Rectal temperature did not change in cold or hot chambers. However, respiration rate nearly doubled in the heat ( P < 0.05), increasing when T a was above 24°C. Skin temperatures at the two locations were highly correlated ( P < 0.05) with each other and with T a. In contrast, sweat rate showed differences at rump and shoulder sites. Sweat rate of the rump exhibited only a small increase with T a. However, sweat rate at the shoulder increased more than four-fold with increasing T a. Increased sweat rate in this region is supported by an earlier report of a higher density of sweat glands in the shoulder compared to rump regions. Sweat rate was correlated with several thermal measurements to determine the best predictor. Fourth-order polynomial expressions of short-term rectal and skin temperature responses to hot and cold exposures produced r values of 0.60, 0.84, and 0.98, respectively. These results suggest that thermal inputs other than just rectal or skin temperature drive the sweat response in cattle.
Minett, Geoffrey M.; Bach, Aaron J. E.; Zietek, Stephanie A.; Stewart, Kelly L.; Stewart, Ian B.
2018-01-01
Objective The present study aimed to compare a range of cooling methods possibly utilised by occupational workers, focusing on their effect on body temperature, perception and manual dexterity. Methods Ten male participants completed eight trials involving 30 min of seated rest followed by 30 min of cooling or control of no cooling (CON) (34°C, 58% relative humidity). The cooling methods utilised were: ice cooling vest (CV0), phase change cooling vest melting at 14°C (CV14), evaporative cooling vest (CVEV), arm immersion in 10°C water (AI), portable water-perfused suit (WPS), heliox inhalation (HE) and ice slushy ingestion (SL). Immediately before and after cooling, participants were assessed for fine (Purdue pegboard task) and gross (grip and pinch strength) manual dexterity. Rectal and skin temperature, as well as thermal sensation and comfort, were monitored throughout. Results Compared with CON, SL was the only method to reduce rectal temperature (P = 0.012). All externally applied cooling methods reduced skin temperature (P<0.05), though CV0 resulted in the lowest skin temperature versus other cooling methods. Participants felt cooler with CV0, CV14, WPS, AI and SL (P<0.05). AI significantly impaired Purdue pegboard performance (P = 0.001), but did not affect grip or pinch strength (P>0.05). Conclusion The present study observed that ice ingestion or ice applied to the skin produced the greatest effect on rectal and skin temperature, respectively. AI should not be utilised if workers require subsequent fine manual dexterity. These results will help inform future studies investigating appropriate pre-cooling methods for the occupational worker. PMID:29357373
Accuracy of tympanic and infrared skin thermometers in children.
Paes, B F; Vermeulen, K; Brohet, R M; van der Ploeg, T; de Winter, J P
2010-12-01
Rectal measurement is considered a gold standard in many healthcare systems for body temperature measurement in children. Although this method has several disadvantages, an ideal alternative thermometer has not yet been introduced. However tympanic and infrared skin thermometers are potential alternatives. A prospective cohort study was performed including 100 children between 0 and 18 years of age admitted to the general paediatric ward of Spaarne Hospital in The Netherlands between January and March 2009. The objectives of this study are to evaluate the accuracy of tympanic and two types of infrared skin thermometers (Beurer and Thermofocus) compared to rectal measurement and furthermore to evaluate the influence of different variables on temperature measurements. Compared to rectal measurement (37.56°C), the mean temperatures of the tympanic (37.29°C), Beurer (36.79°C) and Thermofocus (37.30°C) thermometers differed significantly (p<0.001). Mean and SD of differences between rectal temperature and temperature measured with these alternative devices varied significantly (p<0.001). Sensitivity, specificity, positive and negative predictive values for detecting rectal fever measured with the tympanic, Beurer and Thermofocus thermometers are unacceptable, especially for the Beurer thermometer. This difference in temperature between rectal and the alternative thermometers remained after stratification on gender, age, skin colour and otoscopic abnormalities. In this study the authors demonstrated that the tympanic, Beurer and Thermofocus thermometers cannot reliably predict rectal temperature. Therefore the authors do not advise replacement of rectal measurement as the gold standard for detecting fever in children by one of these devices. When rectal measurement is not used, the infrared skin thermometers appear to perform less well than tympanic measurements.
Effect of ambient temperature on human pain and temperature perception.
Strigo, I A; Carli, F; Bushnell, M C
2000-03-01
Animal studies show reduced nociceptive responses to noxious heat stimuli and increases in endogenous beta-endorphin levels in cold environments, suggesting that human pain perception may be dependent on ambient temperature. However, studies of changes in local skin temperature on human pain perception have yielded variable results. This study examines the effect of both warm and cool ambient temperature on the perception of noxious and innocuous mechanical and thermal stimuli. Ten subjects (7 men and 3 women, aged 20-23 yr) used visual analog scales to rate the stimulus intensity, pain intensity, and unpleasantness of thermal (0-50 degrees C) and mechanical (1.2-28.9 g) stimuli applied on the volar forearm with a 1-cm2 contact thermode and von Frey filaments, respectively. Mean skin temperatures were measured throughout the experiment by infrared pyrometer. Each subject was tested in ambient temperatures of 15 degrees C (cool), 25 degrees C (neutral), and 35 degrees C (warm) on separate days, after a 30-min acclimation to the environment. Studies began in the morning after an 8-h fast. Mean skin temperature was altered by ambient temperature (cool room: 30.1 degrees C; neutral room: 33.4 degrees C; warm room: 34.5 degrees C; P < 0.0001). Ambient temperature affected both heat (44-50 degrees C) and cold (25-0 degrees C) perception (P < 0.01). Stimulus intensity ratings tended to be lower in the cool than in the neutral environment (P < 0.07) but were not different between the neutral and warm environments. Unpleasantness ratings revealed that cold stimuli were more unpleasant than hot stimuli in the cool room and that noxious heat stimuli were more unpleasant in a warm environment. Environmental temperature did not alter ratings of warm (37 and 40 degrees C) or mechanical stimuli. These results indicate that, in humans, a decrease in skin temperature following exposure to cool environments reduces thermal pain. Suppression of Adelta primary afferent cold fiber activity has been shown to increase cold pain produced by skin cooling. Our current findings may represent the reverse phenomenon, i.e., a reduction in thermal nociceptive transmission by the activation of Adelta cutaneous cold fibers.
Recent Progress in Electronic Skin
Wang, Xiandi; Dong, Lin; Zhang, Hanlu; Yu, Ruomeng; Wang, Zhong Lin
2015-01-01
The skin is the largest organ of the human body and can sense pressure, temperature, and other complex environmental stimuli or conditions. The mimicry of human skin's sensory ability via electronics is a topic of innovative research that could find broad applications in robotics, artificial intelligence, and human–machine interfaces, all of which promote the development of electronic skin (e‐skin). To imitate tactile sensing via e‐skins, flexible and stretchable pressure sensor arrays are constructed based on different transduction mechanisms and structural designs. These arrays can map pressure with high resolution and rapid response beyond that of human perception. Multi‐modal force sensing, temperature, and humidity detection, as well as self‐healing abilities are also exploited for multi‐functional e‐skins. Other recent progress in this field includes the integration with high‐density flexible circuits for signal processing, the combination with wireless technology for convenient sensing and energy/data transfer, and the development of self‐powered e‐skins. Future opportunities lie in the fabrication of highly intelligent e‐skins that can sense and respond to variations in the external environment. The rapidly increasing innovations in this area will be important to the scientific community and to the future of human life. PMID:27980911
Runeman, Bo; Rybo, Göran; Forsgren-Brusk, Ulla; Larkö, Olle; Larsson, Peter; Faergemann, Jan
2005-01-01
The aim of the present study was to investigate if tight-fitting underwear (string panties) equipped with string panty liners affected the vulvar skin microenvironment differently to regular panties with standard panty liners. Thirty-two healthy women participated in a crossover study where temperature, humidity, surface pH and aerobic microflora were measured on vulvar skin. Vulvar skin temperature was 35.2 +/- 0.19 (mean +/- SEM) and 35.3 +/- 0.17 degrees C, respectively, for the two underwear systems. Mean humidity and mean skin surface pH at vulvar skin did not differ between the two systems. Barely noticeable differences were found for the aerobic microflora both at labium majus and at perineum. The mean total number of microorganisms in the two different panty liners was the same, 6.0 +/- 0.15 and 6.0 +/- 0.16, respectively (log CFU per panty liner). The differences in panty and panty liner design studied seem to have negligible impact on the vulvar skin microclimate, skin surface pH and aerobic microflora. No support was found for the assumption that a string panty system would result in higher contamination of vulvar skin by anorectal microflora.
Rungruang, S; Collier, J L; Rhoads, R P; Baumgard, L H; de Veth, M J; Collier, R J
2014-01-01
Twenty-four multiparous high-producing dairy cows (40.0±1.4kg/d) were used in a factorial design to evaluate effects of 2 environments [thermoneutral (TN) and heat stress (HS)] and a dose range of dietary rumen-protected niacin (RPN; 0, 4, 8, or 12g/d) on body temperature, sweating rate, feed intake, water intake, production parameters, and blood niacin concentrations. Temperature-humidity index values during TN never exceeded 68 (stress threshold), whereas temperature-humidity index values during HS were above 68 for 24h/d. The HS environment increased hair coat and skin, rectal, and vaginal temperatures; respiration rate; skin and hair coat evaporative heat loss; and water intake and decreased DMI (3.5kg/d), milk yield (4.1kg/d), 4% fat-corrected milk (2.7kg/d), and milk protein yield (181.7g/d). Sweating rate increased during HS (12.7g/m(2) per h) compared with TN, but this increase was only 10% of that reported in summer-acclimated cattle. Niacin supplementation did not affect sweating rate, dry-matter intake, or milk yield in either environment. Rumen-protected niacin increased plasma and milk niacin concentrations in a linear manner. Heat stress reduced niacin concentration in whole blood (7.86 vs. 6.89μg/mL) but not in milk. Reduced blood niacin concentration was partially corrected by dietary RPN. An interaction existed between dietary RPN and environment; dietary RPN linearly increased water intake in both environments, but the increase was greater during HS conditions. Increasing dietary RPN did not influence skin temperatures. During TN, supplementing 12g/d of RPN increased hair coat (unshaved skin; 30.3 vs. 31.3°C at 1600h) but not shaved skin (32.8 vs. 32.9°C at 1600h) temperature when compared with 0g/d at all time points, whereas the maximum temperature (18°C) of the room was lower than skin temperature. These data suggest that dietary RPN increased water intake during both TN and HS and hair coat temperature during TN; however, core body temperature was unaffected. Thus, encapsulated niacin did not improve thermotolerance of winter-acclimated lactating dairy cows exposed to moderate thermal stress in Arizona. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Ohkawara, H; Kitagawa, T; Fukushima, N; Ito, T; Sawa, Y; Yoshimine, T
2012-05-01
As there is only one skin procurement organization in Japan the Japan Skin Bank Network (JSBN), all skin grafts procured in Japan are sent by a commercialized delivery system. Preliminarily, bottles containing saline were transported in a cardboard box using a so-called "cooled home delivery service" using a truck with a refrigerated cargo container. During transportation the temperature in the cardboard box increased to 18°C in summer and decreased to -5°C in winter. For these reasons, we investigated whether a newly developed container "Medi Cube" would be useful to transport skin grafts. Four bottles with a capacity of 300 mL containing 150 mL of saline in a Medi Cube container were transported from Osaka to the JSBN in Tokyo between 4 PM and 10 AM using a commercialized cooled home delivery service. Two bottles were transported in a Medi Cube container without phase change materials (PCM) in winter and summer, respectively. Another two bottles were transported in the Medi Cube with PCMs in winter. The temperatures inside saline, inside a transportation container, and outside the container, and air temperature were monitored continuously with a recordable thermometer. The temperatures inside saline and inside a Medi Cube container were maintained between 3 and 6°C, even when the temperature outside the container increased during parking. The temperature inside a Medi Cube container without PCM decreased to -3°C when the inside of the cargo container was overcooled in winter. However, the temperatures inside saline and inside a Medi Cube container with PCM were between 3 and 6°C, even when the temperature outside the container decreased to below 0°C in winter. A Medi Cube container with PCM provided a safe, easy, and cost-effective method for overnight transportation of skin grafts. Copyright © 2012 Elsevier Inc. All rights reserved.
Therapeutic Magnets Do Not Affect Tissue Temperatures
Sweeney, Kathleen B.; Ingersoll, Christopher D.; Swez, John A.
2001-01-01
Objective: Manufacturers of commercially available “therapeutic” magnets claim that these magnets cause physiologic thermal effects that promote tissue healing. We conducted this study to determine if skin or intramuscular temperatures differed among magnet, sham, and control treatments during 60 minutes of application to the quadriceps muscle. Design and Setting: A 3 × 3 mixed-model, factorial design with repeated measures on both independent variables was used. The first independent variable, application duration, had 3 random levels (20, 40, and 60 minutes). The second independent variable, treatment, had 3 fixed levels (magnet, sham, and control). The dependent variable was tissue temperature (°C). Measurement depth served as a control variable, with 2 levels: skin and 1 cm below the fat layer. Data were collected in a thermoneutral laboratory setting and analyzed using a repeated-measures analysis of variance. Subjects: The study included 13 healthy student volunteers (8 men, 5 women; age, 20.5 ± 0.9 years; height, 176.8 ± 10.4 cm; weight, 73.8 ± 11.8 kg; anterior thigh skinfold thickness, 16.9 ± 6.5 mm). Measurements: Temperatures were measured at 30-second intervals using surface and implantable thermocouples. Temperature data at 20, 40, and 60 minutes were used for analysis. Each subject received all 3 treatments on different days. Results: Neither skin nor intramuscular temperatures were different across the 3 treatments at any time. For both skin and intramuscular temperatures, a statistically significant but not clinically meaningful temperature increase (less than 1°C), was observed over time within treatments, but this increase was similar in all treatment groups. Conclusions: No meaningful thermal effect was observed with any treatment over time, and treatments did not differ from each other. We conclude that flexible therapeutic magnets were not effective for increasing skin or deep temperatures, contradicting one of the fundamental claims made by magnet distributors. PMID:12937511
Hot bats: extreme thermal tolerance in a desert heat wave
NASA Astrophysics Data System (ADS)
Bondarenco, Artiom; Körtner, Gerhard; Geiser, Fritz
2014-08-01
Climate change is predicted to increase temperature extremes and thus thermal stress on organisms. Animals living in hot deserts are already exposed to high ambient temperatures ( T a) making them especially vulnerable to further warming. However, little is known about the effect of extreme heat events on small desert mammals, especially tree-roosting microbats that are not strongly protected from environmental temperature fluctuations. During a heat wave with record T as at Sturt National Park, we quantified the thermal physiology and behaviour of a single free-ranging little broad-nosed ( Scotorepens greyii, henceforth Scotorepens) and two inland freetail bats ( Mormopterus species 3, henceforth Mormopterus) using temperature telemetry over 3 days. On 11 and 13 January, maximum T a was ˜45.0 °C, and all monitored bats were thermoconforming. On 12 January 2013, when T a exceeded 48.0 °C, Scotorepens abandoned its poorly insulated roost during the daytime, whereas both Mormopterus remained in their better insulated roosts and were mostly thermoconforming. Maximum skin temperatures ( T skin) ranged from 44.0 to 44.3 °C in Scotorepens and from 40.0 to 45.8 °C in Mormopterus, and these are the highest T skin values reported for any free-ranging bat. Our study provides the first evidence of extensive heat tolerance in free-ranging desert microbats. It shows that these bats can tolerate the most extreme T skin range known for mammals (3.3 to 45.8 °C) and delay regulation of T skin by thermoconforming over a wide temperature range and thus decrease the risks of dehydration and consequently death.
Safety assessment of near infrared light emitting diodes for diffuse optical measurements
Bozkurt, Alper; Onaral, Banu
2004-01-01
Background Near infrared (NIR) light has been used widely to monitor important hemodynamic parameters in tissue non-invasively. Pulse oximetry, near infrared spectroscopy, and diffuse optical tomography are examples of such NIR light-based applications. These and other similar applications employ either lasers or light emitting diodes (LED) as the source of the NIR light. Although the hazards of laser sources have been addressed in regulations, the risk of LED sources in such applications is still unknown. Methods Temperature increase of the human skin caused by near infrared LED has been measured by means of in-vivo and in-vitro experiments. Effects of the conducted and radiated heat in the temperature increase have been analyzed separately. Results Elevations in skin temperature up to 10°C have been observed. The effect of radiated heat due to NIR absorption is low – less than 0.5°C – since emitted light power is comparable to the NIR part of sunlight. The conducted heat due to semiconductor junction of the LED can cause temperature increases up to 9°C. It has been shown that adjusting operational parameters by amplitude modulating or time multiplexing the LED decreases the temperature increase of the skin significantly. Conclusion In this study, we demonstrate that the major risk source of the LED in direct contact with skin is the conducted heat of the LED semiconductor junction, which may cause serious skin burns. Adjusting operational parameters by amplitude modulating or time multiplexing the LED can keep the LED within safe temperature ranges. PMID:15035670
Self-paced cycling performance and recovery under a hot and highly humid environment after cooling.
Gonzales, B R; Hagin, V; Guillot, R; Placet, V; Monnier-Benoit, P; Groslambert, A
2014-02-01
This study investigated the effects of pre- and post-cooling on self-paced time-trial cycling performance and recovery of cyclists exercising under a hot and highly humid environment (29.92 °C-78.52% RH). Ten male cyclists performed a self-paced 20-min time trial test (TT20) on a cyclo-ergometer while being cooled by a cooling vest and a refrigerating headband during the warm-up and the recovery period. Heart rate, power output, perceived exertion, thermal comfort, skin and rectal temperatures were recorded. Compared to control condition (222.78 ± 47 W), a significant increase (P<0.05) in the mean power output during the TT20 (239.07 ± 45 W; +7.31%) was recorded with a significant (P<0.05) decrease in skin temperature without affecting perceived exertion, heart rate, or rectal temperature at the end of the TT20. However, pace changes occurred independently of skin or rectal temperatures variations but a significant difference (P<0.05) in the body's heat storage was observed between both conditions. This result suggests that a central programmer using body's heat storage as an input may influence self-paced time-trial performance. During the recovery period, post-cooling significantly decreased heart rate, skin and rectal temperatures, and improved significantly (P<0.05) thermal comfort. Therefore, in hot and humid environments, wearing a cooling vest and a refrigerating headband during warm-up improves self-paced performance, and appears to be an effective mean of reaching skin rest temperatures more rapidly during recovery.
NASA Astrophysics Data System (ADS)
Trofimov, Vyacheslav A.; Trofimov, Vladislav V.
2015-05-01
As it is well-known, application of the passive THz camera for the security problems is very promising way. It allows seeing concealed object without contact with a person and this camera is non-dangerous for a person. In previous papers, we demonstrate new possibility of the passive THz camera using for a temperature difference observing on the human skin if this difference is caused by different temperatures inside the body. For proof of validity of our statement we make the similar physical experiment using the IR camera. We show a possibility of temperature trace on human body skin, caused by changing of temperature inside the human body due to water drinking. We use as a computer code that is available for treatment of images captured by commercially available IR camera, manufactured by Flir Corp., as well as our developed computer code for computer processing of these images. Using both codes we demonstrate clearly changing of human body skin temperature induced by water drinking. Shown phenomena are very important for the detection of forbidden samples and substances concealed inside the human body using non-destructive control without X-rays using. Early we have demonstrated such possibility using THz radiation. Carried out experiments can be used for counter-terrorism problem solving. We developed original filters for computer processing of images captured by IR cameras. Their applications for computer processing of images results in a temperature resolution enhancing of cameras.
Thermographic diagnostics to discriminate skin lesions: a clinical study
NASA Astrophysics Data System (ADS)
Stringasci, Mirian Denise; Moriyama, Lilian Tan; Salvio, Ana Gabriela; Bagnato, Vanderlei Salvador; Kurachi, Cristina
2015-06-01
Cancer is responsible for about 13% of all causes of death in the world. Over 7 million people die annually of this disease. In most cases, the survival rates are greater when diagnosed in early stages. It is known that tumor lesions present a different temperature compared with the normal tissues. Some studies have been performed in an attempt to establish new diagnosis methods, targeting this temperature difference. In this study, we aim to investigate the use of a handheld thermographic camera to discriminate skin lesions. The patients presenting Basal Cell Carcinoma, Squamous Cell Carcinoma, Actinic Keratosis, Pigmented Seborrheic Keratosis, Melanoma or Intradermal Nevus lesions have been investigated at the Skin Departament of Amaral Carvalho Hospital. Patients are selected by a dermatologist, and the lesion images are recorded using an infrared camera. The images are evaluated taken into account the temperature level, and differences into lesion areas, borders, and between altered and normal skin. The present results show that thermography may be an important tool for aiding in the clinical diagnostics of superficial skin lesions.
Simhon, David; Halpern, Marisa; Brosh, Tamar; Vasilyev, Tamar; Ravid, Avi; Tennenbaum, Tamar; Nevo, Zvi; Katzir, Abraham
2007-01-01
Background: A feedback temperature-controlled laser soldering system (TCLS) was used for bonding skin incisions on the backs of pigs. The study was aimed: 1) to characterize the optimal soldering parameters, and 2) to compare the immediate and long-term wound healing outcomes with other wound closure modalities. Materials and Methods: A TCLS was used to bond the approximated wound margins of skin incisions on porcine backs. The reparative outcomes were evaluated macroscopically, microscopically, and immunohistochemically. Results: The optimal soldering temperature was found to be 65°C and the operating time was significantly shorter than with suturing. The immediate tight sealing of the wound by the TCLS contributed to rapid, high quality wound healing in comparison to Dermabond or Histoacryl cyanoacrylate glues or standard suturing. Conclusions: TCLS of incisions in porcine skin has numerous advantages, including rapid procedure and high quality reparative outcomes, over the common standard wound closure procedures. Further studies with a variety of skin lesions are needed before advocating this technique for clinical use. PMID:17245173
Thermal sensation during mild hyperthermia is modulated by acute postural change in humans
NASA Astrophysics Data System (ADS)
Takeda, Ryosuke; Imai, Daiki; Suzuki, Akina; Ota, Akemi; Naghavi, Nooshin; Yamashina, Yoshihiro; Hirasawa, Yoshikazu; Yokoyama, Hisayo; Miyagawa, Toshiaki; Okazaki, Kazunobu
2016-12-01
Thermal sensation represents the primary stimulus for behavioral and autonomic thermoregulation. We assessed whether the sensation of skin and core temperatures for the driving force of behavioral thermoregulation was modified by postural change from the supine (Sup) to sitting (Sit) during mild hyperthermia. Seventeen healthy young men underwent measurements of noticeable increase and decrease (±0.1 °C/s) of skin temperature (thresholds of warm and cold sensation on the skin, 6.25 cm2 of area) at the forearm and chest and of the whole-body warm sensation in the Sup and Sit during normothermia (NT; esophageal temperature (Tes), ˜36.6 °C) and mild hyperthermia (HT; Tes, ˜37.2 °C; lower legs immersion in 42 °C of water). The threshold for cold sensation on the skin at chest was lower during HT than NT in the Sit ( P < 0.05) but not in Sup, and at the forearm was lower during HT than NT in the Sup and further in Sit (both, P < 0.05), with interactive effects of temperature (NT vs. HT) × posture (Sup vs. Sit) (chest, P = 0.08; forearm, P < 0.05). The threshold for warm sensation on the skin at both sites remained unchanged with changes in body posture or temperature. The whole-body warm sensation was higher during HT than NT in both postures and higher in the Sit than Sup during both NT and HT (all, P < 0.05). Thus, thermal sensation during mild hyperthermia is modulated by postural change from supine to sitting to sense lesser cold on the skin and more whole-body warmth.
Thermal sensation during mild hyperthermia is modulated by acute postural change in humans.
Takeda, Ryosuke; Imai, Daiki; Suzuki, Akina; Ota, Akemi; Naghavi, Nooshin; Yamashina, Yoshihiro; Hirasawa, Yoshikazu; Yokoyama, Hisayo; Miyagawa, Toshiaki; Okazaki, Kazunobu
2016-12-01
Thermal sensation represents the primary stimulus for behavioral and autonomic thermoregulation. We assessed whether the sensation of skin and core temperatures for the driving force of behavioral thermoregulation was modified by postural change from the supine (Sup) to sitting (Sit) during mild hyperthermia. Seventeen healthy young men underwent measurements of noticeable increase and decrease (±0.1 °C/s) of skin temperature (thresholds of warm and cold sensation on the skin, 6.25 cm 2 of area) at the forearm and chest and of the whole-body warm sensation in the Sup and Sit during normothermia (NT; esophageal temperature (T es ), ∼36.6 °C) and mild hyperthermia (HT; T es , ∼37.2 °C; lower legs immersion in 42 °C of water). The threshold for cold sensation on the skin at chest was lower during HT than NT in the Sit (P < 0.05) but not in Sup, and at the forearm was lower during HT than NT in the Sup and further in Sit (both, P < 0.05), with interactive effects of temperature (NT vs. HT) × posture (Sup vs. Sit) (chest, P = 0.08; forearm, P < 0.05). The threshold for warm sensation on the skin at both sites remained unchanged with changes in body posture or temperature. The whole-body warm sensation was higher during HT than NT in both postures and higher in the Sit than Sup during both NT and HT (all, P < 0.05). Thus, thermal sensation during mild hyperthermia is modulated by postural change from supine to sitting to sense lesser cold on the skin and more whole-body warmth.
Churyukanov, Maxim; Plaghki, Léon; Legrain, Valéry; Mouraux, André
2012-01-01
Brief high-power laser pulses applied onto the hairy skin of the distal end of a limb generate a double sensation related to the activation of Aδ- and C-fibres, referred to as first and second pain. However, neurophysiological and behavioural responses related to the activation of C-fibres can be studied reliably only if the concomitant activation of Aδ-fibres is avoided. Here, using a novel CO2 laser stimulator able to deliver constant-temperature heat pulses through a feedback regulation of laser power by an online measurement of skin temperature at target site, combined with an adaptive staircase algorithm using reaction-time to distinguish between responses triggered by Aδ- and C-fibre input, we show that it is possible to estimate robustly and independently the thermal detection thresholds of Aδ-fibres (46.9±1.7°C) and C-fibres (39.8±1.7°C). Furthermore, we show that both thresholds are dependent on the skin temperature preceding and/or surrounding the test stimulus, indicating that the Aδ- and C-fibre afferents triggering the behavioural responses to brief laser pulses behave, at least partially, as detectors of a change in skin temperature rather than as pure level detectors. Most importantly, our results show that the difference in threshold between Aδ- and C-fibre afferents activated by brief laser pulses can be exploited to activate C-fibres selectively and reliably, provided that the rise in skin temperature generated by the laser stimulator is well-controlled. Our approach could constitute a tool to explore, in humans, the physiological and pathophysiological mechanisms involved in processing C- and Aδ-fibre input, respectively. PMID:22558230
Bach, Aaron J E; Stewart, Ian B; Disher, Alice E; Costello, Joseph T
2015-01-01
Skin temperature assessment has historically been undertaken with conductive devices affixed to the skin. With the development of technology, infrared devices are increasingly utilised in the measurement of skin temperature. Therefore, our purpose was to evaluate the agreement between four skin temperature devices at rest, during exercise in the heat, and recovery. Mean skin temperature ([Formula: see text]) was assessed in thirty healthy males during 30 min rest (24.0 ± 1.2°C, 56 ± 8%), 30 min cycle in the heat (38.0 ± 0.5°C, 41 ± 2%), and 45 min recovery (24.0 ± 1.3°C, 56 ± 9%). [Formula: see text] was assessed at four sites using two conductive devices (thermistors, iButtons) and two infrared devices (infrared thermometer, infrared camera). Bland-Altman plots demonstrated mean bias ± limits of agreement between the thermistors and iButtons as follows (rest, exercise, recovery): -0.01 ± 0.04, 0.26 ± 0.85, -0.37 ± 0.98°C; thermistors and infrared thermometer: 0.34 ± 0.44, -0.44 ± 1.23, -1.04 ± 1.75°C; thermistors and infrared camera (rest, recovery): 0.83 ± 0.77, 1.88 ± 1.87°C. Pairwise comparisons of [Formula: see text] found significant differences (p < 0.05) between thermistors and both infrared devices during resting conditions, and significant differences between the thermistors and all other devices tested during exercise in the heat and recovery. These results indicate poor agreement between conductive and infrared devices at rest, during exercise in the heat, and subsequent recovery. Infrared devices may not be suitable for monitoring [Formula: see text] in the presence of, or following, metabolic and environmental induced heat stress.
Jay, Ollie; Havenith, George
2006-05-01
To assess the presence and magnitude of the effect of skin blood flow on finger skin cooling on contact with cold objects against the background of circulatory disorder risks in occupational exposures, this study investigates the effect of zero vs. close-to-maximal hand blood flow on short-term (< or =180 s) skin contact cooling response at a contact pressure that allows capillary perfusion of the distal pulp of the fingertip. Six male volunteers touched a block of aluminium with a finger contact force of 0.5 N at a temperature of -2 degrees C under a vasodilated and an occluded condition. Before both conditions, participants were required to exercise in a hot room for > or = 30 min for cutaneous vasodilation to occur (increase in rectal temperature of 1 degrees C). Under the vasodilated condition, forearm blood flow rate rose as high as 16.8 ml.100 ml(-1).min(-1). Under the occluded condition, the arm was exsanguinated, after which a blood pressure cuff was secured on the wrist inducing arterial occlusion. Contact temperature of the finger pad during the subsequent cold contact exposure was measured. No significant difference was found between the starting skin temperatures for the two blood flow conditions, but a distinct difference in shape of the contact cooling curve was apparent between the two blood flow conditions, with Newtonian cooling observed under the occluded condition, whereas a rewarming of the finger skin toward the end of the exposure occurred for the vasodilated condition. Blood flow was found to significantly increase contact temperature from 40 s onward (P < 0.01). It is concluded that, at a finger contact force compatible with capillary perfusion of the finger pad ( approximately 0.5 N), circulating blood provides a heat input source that significantly affects finger skin contact cooling during a vasodilated state.
2013-07-01
www.le.ac.uk/ge/collagen/), in addition to mutations on COL1A1 and COL5A2. These mutations result in amino acid substitutions, RNA splicing...fibrillogenesis of type I collagen resulting in thinner collagen fibrils [29]. In the absence of PIIINP, Romanic and colleagues demonstrate that COL1A1 is...larger, shorter, and apparently stiffer; whereas in the presence of PIIINP/ COL1A1 copolymer, the type I collagen was longer, thinner, and more
NASA Technical Reports Server (NTRS)
Bales, Thomas T.
1992-01-01
Vugraphs are presented to show the use of refractory materials for the skin of the High speed Civil Transport (HSCT). Examples are given of skin temperature ranges, failure mode weight distribution, tensile properties as a function of temperature, and components to be constructed from composite materials. The responsibilities of various aircraft companies for specific aircraft components are defined.
Yoshimura, Mine; Nakagami, Gojiro; Iizaka, Shinji; Yoshida, Mikako; Uehata, Yoko; Kohno, Michihiro; Kasuya, Yusuke; Mae, Tomoko; Yamasaki, Takashi; Sanada, Hiromi
2015-01-01
Preventing pressure ulcers is important in patients undergoing procedures in the park-bench position. We hypothesized that the microclimate around the skin is a significant risk factor for developing pressure ulcers. This research continuously assessed factors of the microclimate in terms of skin temperature and perspiration as well as the interface pressure in order to determine whether the microclimate is an independent risk factor for the development of park-bench position-related pressure ulcers (PBP-PUs). A prospective observational study was conducted among patients undergoing elective surgery in the park-bench position at a general hospital in the metropolitan area of Japan between April and November 2014. Factors of the microclimate, including skin temperature and perspiration, in addition to the interface pressure were continuously measured throughout surgery. Twenty-nine patients were analyzed (mean age 44.4 ± 13.2 years, male 44.8%). Of these 29 patients, seven (24.1%) developed Category I PBP-PUs. The change in skin temperature from baseline to the end of surgery (2.7 ± 0.3 °C vs. 1.9 ± 0.8 °C) and the average peak pressure (119.1 ± 36.8 mmHg vs. 94.5 ± 23.1 mmHg) were significantly higher in the patients with PBP-PUs than in those without PBP-PUs. There were no significant differences in the amount of perspiration between the two groups. A hierarchical logistic regression analysis showed that the change in skin temperature was significantly related to the development of PBP-PUs (unit = 0.1 °C: odds ratio 1.44, 95% confidential interval 1.09-2.33) when adjusted for the average peak pressure and length of surgery. Our results suggest that a change in skin temperature toward a higher value is an independent risk factor for the development of PBP-PUs. Proper intraoperative management of skin temperature may therefore be a promising candidate as a preventive method against PBP-PU development. © 2015 by the Wound Healing Society.
Lee, Young-Mee
2011-02-01
The purpose of this study was to evaluate the effects of self-foot reflexology on stress (perceived stress, urine cortisol level, and serum cortisol level), fatigue, skin temperature and immune response in female undergraduate students. The research design was a nonequivalent control group pretest-post test design. Participants were 60 university students: 30 in the experiment group and 30 in the control group. The period of this study was from April to June 2010. The program was performed for 1 hr a session, three times a week for 6 weeks. The data were analyzed using the SPSS/WIN 17.0 program. The results showed that self-foot reflexology was effective in reducing perceived stress and fatigue, and raised skin temperature in female undergraduate students. But cortisol levels and immune response were not statistically significant different. The results of this study indicate that self-foot reflexology is an effective nursing intervention in reducing perceived stress and fatigue and, in improving skin temperature. Therefore, it is recommended that this be used in clinical practice as an effective nursing intervention for in female undergraduate students.
NASA Astrophysics Data System (ADS)
Zhao, Shu-Xia
2018-03-01
In this work, the behavior of electron temperature against the power in argon inductively coupled plasma is investigated by a fluid model. The model properly reproduces the non-monotonic variation of temperature with power observed in experiments. By means of a novel electron mean energy equation proposed for the first time in this article, this electron temperature behavior is interpreted. In the overall considered power range, the skin effect of radio frequency electric field results in localized deposited power density, responsible for an increase of electron temperature with power by means of one parameter defined as power density divided by electron density. At low powers, the rate fraction of multistep and Penning ionizations of metastables that consume electron energy two times significantly increases with power, which dominates over the skin effect and consequently leads to the decrease of temperature with power. In the middle power regime, a transition region of temperature is given by the competition between the ionizing effect of metastables and the skin effect of electric field. The power location where the temperature alters its trend moves to the low power end as increasing the pressure due to the lack of metastables. The non-monotonic curve of temperature is asymmetric at the short chamber due to the weak role of skin effect in increasing the temperature and tends symmetric when axially prolonging the chamber. Still, the validity of the fluid model in this prediction is estimated and the role of neutral gas heating is guessed. This finding is helpful for people understanding the different trends of temperature with power in the literature.
Guo, Hui; Liu, Xia-Lei; Wang, Yu-Ling; Li, Jing-Yi; Lu, Wu-Zhu; Xian, Jian-Zhong; Zhang, Bai-Meng; Li, Jian
2014-06-01
This study was to evaluate the efficacy of subcutaneous administration of 5% dextrose in water (D5W), to prevent skin injury during radiofrequency (RF) ablation. Twenty-four rabbits were divided into three groups: a pre-injection group, a perfusion group, and a control group. Ablative zones were created in the superficial part of the thigh muscle for 6 min. A needle was placed subcutaneously for injection of D5W, and a thermal sensor was positioned nearby for real-time temperature monitoring. The sizes of the ablative zones were measured by contrast-enhanced ultrasonography, and severity of the observed skin injury were scored semi-quantitatively and compared. The highest temperature, the duration of the temperature above 50 °C, and the rise time of the post-procedure temperature were all highest in the control group (p < 0.001), while these values were lower in the perfusion group than those in the pre-injection group (p < 0.001). Post-procedure skin injury was most severe in the control group (p < 0.001). On post-procedure day 1, no significant difference was found between the skin injury of the pre-injection group and the perfusion group (p = 0.091), while the skin injury of the perfusion group was less severe than that of the pre-injection group on post-procedure day 14 (p = 0.004). No significant difference was found in the sizes of the ablative zones among the groups (p = 0.720). Subcutaneous perfusion with D5W is effective in protecting the skin against burns during RF ablation without compromising the effect of ablation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Santa Cruz, G. A.; Gonzalez, S. J.; Bertotti, J.
2009-10-15
Purpose: The purpose of this study is to assess the potential of dynamic infrared imaging (DIRI) as a functional, noninvasive technique for evaluating the skin acute toxicity and tumor control within the framework of the Argentine boron neutron capture therapy (BNCT) program for cutaneous malignant melanoma. Methods: Two patients enrolled in the Argentine phase I/II BNCT clinical trial for cutaneous malignant melanoma were studied with DIRI. An uncooled infrared camera, providing a video output signal, was employed to register the temperature evolution of the normal skin and tumor regions in patients subjected to a mild local cooling (cold stimulus). Inmore » order to study the spatial correlation between dose and acute skin reactions, three-dimensional representations of the superficial dose delivered to skin were constructed and cameralike projections of the dose distribution were coregistered with visible and infrared images. Results: The main erythematous reaction was observed clinically between the second and fifth week post-BNCT. Concurrently, with its clinical onset, a reactive increase above the basal skin temperature was observed with DIRI in the third week post-BNCT within regions that received therapeutic doses. Melanoma nodules appeared as highly localized hyperthermic regions. 2 min after stimulus, these regions reached a temperature plateau and increased in size. Temperature differences with respect to normal skin up to 10 deg. C were observed in the larger nodules. Conclusions: Preliminary results suggest that DIRI, enhanced by the application of cold stimuli, may provide useful functional information associated with the metabolism and vasculature of tumors and inflammatory processes related to radiation-induced changes in the skin as well. These capabilities are aimed at complementing the clinical observations and standard imaging techniques, such as CT and Doppler ultrasound.« less
Incorporating neurophysiological concepts in mathematical thermoregulation models
NASA Astrophysics Data System (ADS)
Kingma, Boris R. M.; Vosselman, M. J.; Frijns, A. J. H.; van Steenhoven, A. A.; van Marken Lichtenbelt, W. D.
2014-01-01
Skin blood flow (SBF) is a key player in human thermoregulation during mild thermal challenges. Various numerical models of SBF regulation exist. However, none explicitly incorporates the neurophysiology of thermal reception. This study tested a new SBF model that is in line with experimental data on thermal reception and the neurophysiological pathways involved in thermoregulatory SBF control. Additionally, a numerical thermoregulation model was used as a platform to test the function of the neurophysiological SBF model for skin temperature simulation. The prediction-error of the SBF-model was quantified by root-mean-squared-residual (RMSR) between simulations and experimental measurement data. Measurement data consisted of SBF (abdomen, forearm, hand), core and skin temperature recordings of young males during three transient thermal challenges (1 development and 2 validation). Additionally, ThermoSEM, a thermoregulation model, was used to simulate body temperatures using the new neurophysiological SBF-model. The RMSR between simulated and measured mean skin temperature was used to validate the model. The neurophysiological model predicted SBF with an accuracy of RMSR < 0.27. Tskin simulation results were within 0.37 °C of the measured mean skin temperature. This study shows that (1) thermal reception and neurophysiological pathways involved in thermoregulatory SBF control can be captured in a mathematical model, and (2) human thermoregulation models can be equipped with SBF control functions that are based on neurophysiology without loss of performance. The neurophysiological approach in modelling thermoregulation is favourable over engineering approaches because it is more in line with the underlying physiology.
NASA Technical Reports Server (NTRS)
Beumer, Ronald J.
1989-01-01
The effectiveness of different low air velocities in maintaining thermal comfort and homeostasis during exercise at space station operational temperature and humidity was investigated. Five male subjects exercised on a treadmill for successive ten minute periods at 60, 71, and 83 percent of maximum oxygen consumption at each of four air velocities, 30, 50, 80, and 120 ft/min, at 22 C and 62 percent relative humidity. No consistent trends or statistically significant differences between air velocities were found in body weight loss, sweat accumulation, or changes in rectal, skin, and body temperatures. Occurrence of the smallest body weight loss at 120 ft/min, the largest sweat accumulation at 30 ft/min, and the smallest rise in rectal temperature and the greatest drop in skin temperature at 120 ft/min all suggested more efficient evaporative cooling at the highest velocity. Heat storage at all velocities was evidenced by increased rectal and body temperatures; skin temperatures declined or increased only slightly. Body and rectal temperature increases corresponded with increased perception of warmth and slight thermal discomfort as exercise progressed. At all air velocities, mean thermal perception never exceeded warm and mean discomfort, greatest at 30 ft/min, was categorized at worst as uncomfortable; sensation of thermal neutrality and comfort returned rapidly after cessation of exercise. Suggestions for further elucidation of the effects of low air velocities on thermal comfort and homeostasis include larger numbers of subjects, more extensive skin temperature measurements and more rigorous analysis of the data from this study.
Kiyatkin, Eugene A.
2010-01-01
Although pharmacological blockade of both dopamine (DA) and opiate receptors has an inhibiting effect on appetitive motivated behaviors, it is still unclear which physiological mechanisms affected by these treatments underlie the behavioral deficit. To clarify this issue, we examined how pharmacological blockade of either DA (SCH23390 + eticlopride at 0.2 mg/kg each) or opioid receptors (naloxone 1 mg/kg) affects motor activity and temperature fluctuations in the nucleus acumens (NAcc), temporal muscle, and facial skin associated with motivated Coca-Cola drinking behavior in rats. In drug-free conditions, presentation of a cup containing 5 ml of Coca-Cola induced locomotor activation and rapid NAcc temperature increases, which both transiently decreased during drinking, and phasically increased again after the cup was emptied. Muscle temperatures followed this pattern, but increases were weaker and more delayed than those in the NAcc. Skin temperature rapidly dropped after cup presentation, remained at low levels during consumption, and slowly restored during post-consumption behavioral activation. By itself, DA receptor blockade induced robust decrease in spontaneous locomotion, moderate increases in brain and muscle temperatures, and a relative increase in skin temperatures, suggesting metabolic activation coupled with adynamia. Following this treatment (∼180 min), motor activation to cup presentation and Coca-Cola consumption were absent, but rats showed NAcc and muscle temperature increases following cup presentation comparable to control. Therefore, DA receptor blockade does not affect significantly central and peripheral autonomic responses to appetitive stimuli, but eliminates their behavior-activating effects, thus disrupting appetitive behavior and blocking consumption. Naloxone alone slightly decreased brain and muscle temperatures and increased skin temperatures, pointing at the enhanced heat loss and possible minor inhibition of basal metabolic activity. This treatment (∼60 min) had minimal effects on the latencies of drinking, but increased its total duration, with licking interrupted by pauses and retreats. This behavioral attenuation was coupled with weaker than in control locomotor activation and diminished temperature fluctuations in each recording location. Therefore, attenuation of normal behavioral and physiological responses to appetitive stimuli appears to underlie modest inhibiting effects of opiate receptor blockade on motivated behavior and consumption. PMID:20167257
Renero-C, Francisco-J
2018-01-01
Background: One of the complications of the diabetes mellitus is the amputation of the lower limbs. This complication may be developed after an insidious ulcer, that may be raised by the peripheral neuropathy or the ischaemic limb, and that the ulcer get infected. That is, to develop an ulcer, in the diabetic patient, three factors should be taken into the account, the autonomic nervous system, the blood supply and the inmune system. Methods: In this work, the thermogram is used to identify regions on the plantar skin with blood supply deficiencies and the behaviour of the thermoregulation process. Within the thermogram of the plantar skin, it can be identify local regions with low and high temperatures that corresponds to ischemic or inflammatory process on that part of the skin. Results: The findings within the 186 thermograms of diabetic patients, obtained from three hospitals and from INAOE facilities, showed, first, the thermograms of the plantar skin of two diabetic patients, acquired in two different times show that the temperature distribution and the average temperatures, vary slightly for a period of weeks. Second, the thermograms of two patients, who both developed insidious ulcers which evolved favourable, demonstrated the importance of the immune system and the drug therapy. These patients are, one who has a Charcot foot, and in the second one, the patient had loss the sensibility of the feet. Finally, the thermograms of two patients, showing abrupt temperature change within small regions in the plantar skin, are discussed. Conclusion: A diabetic patient, with an asymmetric thermogram, as physiological interpretation of the thermoregulation, may indicate a decrease of the blood supply, which may be corroborated by vascular ultrasound. The regions of abrupt temperature change, cold or hot spots, may correspond to ischaemic or inflammatory processes.
Renero-C, Francisco-J
2018-01-01
ABSTRACT Background: One of the complications of the diabetes mellitus is the amputation of the lower limbs. This complication may be developed after an insidious ulcer, that may be raised by the peripheral neuropathy or the ischaemic limb, and that the ulcer get infected. That is, to develop an ulcer, in the diabetic patient, three factors should be taken into the account, the autonomic nervous system, the blood supply and the inmune system. Methods: In this work, the thermogram is used to identify regions on the plantar skin with blood supply deficiencies and the behaviour of the thermoregulation process. Within the thermogram of the plantar skin, it can be identify local regions with low and high temperatures that corresponds to ischemic or inflammatory process on that part of the skin. Results: The findings within the 186 thermograms of diabetic patients, obtained from three hospitals and from INAOE facilities, showed, first, the thermograms of the plantar skin of two diabetic patients, acquired in two different times show that the temperature distribution and the average temperatures, vary slightly for a period of weeks. Second, the thermograms of two patients, who both developed insidious ulcers which evolved favourable, demonstrated the importance of the immune system and the drug therapy. These patients are, one who has a Charcot foot, and in the second one, the patient had loss the sensibility of the feet. Finally, the thermograms of two patients, showing abrupt temperature change within small regions in the plantar skin, are discussed. Conclusion: A diabetic patient, with an asymmetric thermogram, as physiological interpretation of the thermoregulation, may indicate a decrease of the blood supply, which may be corroborated by vascular ultrasound. The regions of abrupt temperature change, cold or hot spots, may correspond to ischaemic or inflammatory processes. PMID:29410772
Device Would Monitor Body Parameters Continuously
NASA Technical Reports Server (NTRS)
Cook, Joseph S., Jr.
1995-01-01
Proposed miniature electronic circuit continuously measures temperature of human subject. Once mounted on subject's skin with medical adhesive tape, electronic thermometer remains in thermal equilibrium with subject's body; thereafter, no need to wait until thermometer reaches body temperature before taking reading. Design provides for switches used to set alarm alerting medical attendants if subject's temperature exceeds critical level. For use on very young child, electronic thermometer sewed into shirt or other suitable garment; device held in contact with skin, and child could not swallow it. Replacement of sensor and computing algorithm changes temperature monitor to cardiorespiratory monitor.
Laistler, Elmar; Poirier-Quinot, Marie; Lambert, Simon A; Dubuisson, Rose-Marie; Girard, Olivier M; Moser, Ewald; Darrasse, Luc; Ginefri, Jean-Christophe
2015-02-01
To demonstrate the feasibility of a highly sensitive superconducting surface coil for microscopic MRI of the human skin in vivo in a clinical 1.5 Tesla (T) scanner. A 12.4-mm high-temperature superconducting coil was used at 1.5T for phantom and in vivo skin imaging. Images were inspected to identify fine anatomical skin structures. Signal-to-noise ratio (SNR) improvement by the high-temperature superconducting (HTS) coil, as compared to a commercial MR microscopy coil was quantified from phantom imaging; the gain over a geometrically identical coil made from copper (cooled or not) was theoretically deduced. Noise sources were identified to evaluate the potential of HTS coils for future studies. In vivo skin images with isotropic 80 μm resolution were demonstrated revealing fine anatomical structures. The HTS coil improved SNR by a factor 32 over the reference coil in a nonloading phantom. For calf imaging, SNR gains of 380% and 30% can be expected over an identical copper coil at room temperature and 77 K, respectively. The high sensitivity of HTS coils allows for microscopic imaging of the skin at 1.5T and could serve as a tool for dermatology in a clinical setting. © 2013 Wiley Periodicals, Inc.
Autonomic nervous system response patterns specificity to basic emotions.
Collet, C; Vernet-Maury, E; Delhomme, G; Dittmar, A
1997-01-12
The aim of this study was to test the assumption that the autonomic nervous system responses to emotional stimuli are specific. A series of six slides was randomly presented to the subjects while six autonomic nervous system (ANS) parameters were recorded: skin conductance, skin potential, skin resistance, skin blood flow, skin temperature and instantaneous respiratory frequency. Each slide induced a basic emotion: happiness, surprise, anger, fear, sadness and disgust. Results have been first considered with reference to electrodermal responses (EDR) and secondly through thermo-vascular and respiratory variations. Classical as well as original indices were used to quantify autonomic responses. The six basic emotions were distinguished by Friedman variance analysis. Thus, ANS values corresponding to each emotion were compared two-by-two. EDR distinguished 13 emotion-pairs out of 15. 10 emotion-pairs were separated by skin resistance as well as skin conductance ohmic perturbation duration indices whereas conductance amplitude was only capable of distinguishing 7 emotion-pairs. Skin potential responses distinguished surprise and fear from sadness, and fear from disgust, according to their elementary pattern analysis in form and sign. Two-by-two comparisons of skin temperature, skin blood flow (estimated by the new non-oscillary duration index) and instantaneous respiratory frequency, enabled the distinction of 14 emotion-pairs out of 15. 9 emotion-pairs were distinguished by the non-oscillatory duration index values. Skin temperature was demonstrated to be different i.e. positive versus negative in response to anger and fear. The instantaneous respiratory frequency perturbation duration index was the only one capable of separating sadness from disgust. From the six ANS parameters study, different autonomic patterns were identified, each characterizing one of the six basic emotion used as inducing signals. No index alone, nor group of parameters (EDR and thermovascular for instance) were capable of distinguishing each emotion from another. However, electrodermal, thermo-vascular and respiratory responses taken as a whole, redundantly separated each emotion thus demonstrating the specificity of autonomic patterns.
Bakker, Akke; Holman, Rebecca; Rodrigues, Dario B; Dobšíček Trefná, Hana; Stauffer, Paul R; van Tienhoven, Geertjan; Rasch, Coen R N; Crezee, Hans
2018-04-27
Tumor response and treatment toxicity are related to minimum and maximum tissue temperatures during hyperthermia, respectively. Using a large set of clinical data, we analyzed the number of sensors required to adequately monitor skin temperature during superficial hyperthermia treatment of breast cancer patients. Hyperthermia treatments monitored with >60 stationary temperature sensors were selected from a database of patients with recurrent breast cancer treated with re-irradiation (23 × 2 Gy) and hyperthermia using single 434 MHz applicators (effective field size 351-396 cm 2 ). Reduced temperature monitoring schemes involved randomly selected subsets of stationary skin sensors, and another subset simulating continuous thermal mapping of the skin. Temperature differences (ΔT) between subsets and complete sets of sensors were evaluated in terms of overall minimum (T min ) and maximum (T max ) temperature, as well as T90 and T10. Eighty patients were included yielding a total of 400 hyperthermia sessions. Median ΔT was <0.01 °C for T90, its 95% confidence interval (95%CI) decreased to ≤0.5 °C when >50 sensors were used. Subsets of <10 sensors result in underestimation of T max up to -2.1 °C (ΔT 95%CI), which decreased to -0.5 °C when >50 sensors were used. Thermal profiles (8-21 probes) yielded a median ΔT < 0.01 °C for T90 and T max , with a 95%CI of -0.2 °C and 0.4 °C, respectively. The detection rate of T max ≥43 °C is ≥85% while using >50 stationary sensors or thermal profiles. Adequate coverage of the skin temperature distribution during superficial hyperthermia treatment requires the use of >50 stationary sensors per 400 cm 2 applicator. Thermal mapping is a valid alternative.
Performance evaluation of Iranian cooling vest on the physiological indices in hot climatic chamber
Dehghan, Habibollah; Gharehbaei, Somayeh; Mahaki, Behzad
2016-01-01
Background: Heat stress is a threat to those who work in high temperatures. The purpose in this study was an examination of the cooling ability of Iranian phase change material (PCM) cold vest in hot and dry conditions in a climatic chamber. Materials and Methods: This experimental study was implemented on 12 male students (age 23.7 ± 2.8 years, weight 66.1 ± 11.4 kg, and VO2 max 2.53 L/min) in 2013. The heat strain score index (HSSI), skin temperature and oral temperature, and heartbeat in two phases with and without cooling vest was measured during 30 min in a climatic chamber (temperature 38.8 ± 1.3°C humidity ratio 32.9 ± 2.3%) and in two activity intensity of 2.4 and 4.8 km/h speed on the treadmill, and the data differences between groups “with” and “without” vest were tested by t-test and repeated measurement. The level of significance was considered as 0.05. Results: The change in heartbeat at two activities, the oral temperature and heat strain score at 4.8 km/h, did not differ significantly between groups (with and without vest), as expected (P > 0.05). However, the change in skin temperature at two activities, oral temperature and heat strain score at 2.4 km/h, was significant between groups, as expected (P < 0.05). The average of skin temperature at 15th and 30th min during the experiment at two activities of 2.4 and 4.8 km/h was significant. Conclusion: The findings of the study indicated that using the Iranian PCM cold vest in hot and dry climate can affect the reduction of skin temperature, oral temperature, and HSSI in light activities. PMID:27500168
Performance evaluation of Iranian cooling vest on the physiological indices in hot climatic chamber.
Dehghan, Habibollah; Gharehbaei, Somayeh; Mahaki, Behzad
2016-01-01
Heat stress is a threat to those who work in high temperatures. The purpose in this study was an examination of the cooling ability of Iranian phase change material (PCM) cold vest in hot and dry conditions in a climatic chamber. This experimental study was implemented on 12 male students (age 23.7 ± 2.8 years, weight 66.1 ± 11.4 kg, and VO2 max 2.53 L/min) in 2013. The heat strain score index (HSSI), skin temperature and oral temperature, and heartbeat in two phases with and without cooling vest was measured during 30 min in a climatic chamber (temperature 38.8 ± 1.3°C humidity ratio 32.9 ± 2.3%) and in two activity intensity of 2.4 and 4.8 km/h speed on the treadmill, and the data differences between groups "with" and "without" vest were tested by t-test and repeated measurement. The level of significance was considered as 0.05. The change in heartbeat at two activities, the oral temperature and heat strain score at 4.8 km/h, did not differ significantly between groups (with and without vest), as expected (P > 0.05). However, the change in skin temperature at two activities, oral temperature and heat strain score at 2.4 km/h, was significant between groups, as expected (P < 0.05). The average of skin temperature at 15(th) and 30(th) min during the experiment at two activities of 2.4 and 4.8 km/h was significant. The findings of the study indicated that using the Iranian PCM cold vest in hot and dry climate can affect the reduction of skin temperature, oral temperature, and HSSI in light activities.
Yoshida-Amano, Yasuko; Nomura, Tomoko; Sugiyama, Yoshinori; Iwata, Kayoko; Higaki, Yuko; Tanahashi, Masanori
2017-02-01
Cutaneous blood flow plays an important role in the thermoregulation, oxygen supply, and nutritional support necessary to maintain the skin. However, there is little evidence for a link between blood flow and skin physiology. Therefore, we conducted surveys of healthy volunteers to determine the relationship(s) between dry skin properties and cutaneous vascular function. Water content of the stratum corneum, transepidermal water loss, and visual dryness score were investigated as dry skin parameters. Cutaneous blood flow in the resting state, the recovery rate (RR) of skin temperature on the hand after a cold-stress test, and the responsiveness of facial skin blood flow to local cooling were examined as indices of cutaneous vascular functions. The relationships between dry skin parameters and cutaneous vascular functions were assessed. The RR correlated negatively with the visual dryness score of skin on the leg but correlated positively with water content of the stratum corneum on the arm. No significant correlation between the resting state of blood flow and dry skin parameters was observed. In both the face and the body, deterioration in skin dryness from summer to winter was significant in subjects with low RR. The RR correlated well with the responsiveness of facial skin blood flow to local cooling, indicating that the RR affects systemic dry skin conditions. These results suggest that the RR but not blood flow at the resting state is associated with dry skin conditions and is involved in skin homeostasis during seasonal environmental changes. © 2016 The Authors. International Journal of Dermatology published by John Wiley & Sons Ltd on behalf of International Society of Dermatology.
A Flexible and Wearable Human Stress Monitoring Patch
Yoon, Sunghyun; Sim, Jai Kyoung; Cho, Young-Ho
2016-01-01
A human stress monitoring patch integrates three sensors of skin temperature, skin conductance, and pulsewave in the size of stamp (25 mm × 15 mm × 72 μm) in order to enhance wearing comfort with small skin contact area and high flexibility. The skin contact area is minimized through the invention of an integrated multi-layer structure and the associated microfabrication process; thus being reduced to 1/125 of that of the conventional single-layer multiple sensors. The patch flexibility is increased mainly by the development of flexible pulsewave sensor, made of a flexible piezoelectric membrane supported by a perforated polyimide membrane. In the human physiological range, the fabricated stress patch measures skin temperature with the sensitivity of 0.31 Ω/°C, skin conductance with the sensitivity of 0.28 μV/0.02 μS, and pulse wave with the response time of 70 msec. The skin-attachable stress patch, capable to detect multimodal bio-signals, shows potential for application to wearable emotion monitoring. PMID:27004608
Dynamics of laser ablation at the early stage during and after ultrashort pulse
NASA Astrophysics Data System (ADS)
Ilnitsky, D. K.; Khokhlov, V. A.; Zhakhovsky, V. V.; Petrov, Yu V.; Migdal, K. P.; Inogamov, N. A.
2016-11-01
Study of material flow in two-temperature states is needed for a fundamental understanding the physics of femtosecond laser ablation. To explore phenomena at a very early stage of laser action on a metallic target our in-house two-temperature hydrodynamics code is used here. The early stage covers duration of laser pulse with next first few picoseconds. We draw attention to the difference in behavior at this stage between the cases: (i) of an ultrathin film (thickness of order of skin depth d skin or less), (ii) thin films (thickness of a film is 4-7 of d skin for gold), and (iii) bulk targets (more than 10d skin for gold). We demonstrate that these differences follow from a competition among conductive cooling of laser excited electrons in a skin layer, electron-ion coupling, and hydrodynamics of unloading caused by excess of pressure of excited free electrons. Conductive cooling of the skin needs a heat sink, which is performed by the cold material outside the skin. Such sink is unavailable in the ultrathin films.
Interaction of 1.319 μm laser with skin: an optical-thermal-damage model and experimental validation
NASA Astrophysics Data System (ADS)
Jiao, Luguang; Yang, Zaifu; Wang, Jiarui
2014-09-01
With the widespread use of high-power laser systems operating within the wavelength region of approximately 1.3 to 1.4 μm, it becomes very necessary to refine the laser safety guidelines setting the exposure limits for the eye and skin. In this paper, an optical-thermal-damage model was developed to simulate laser propagation, energy deposition, heat transfer and thermal damage in the skin for 1.319 μm laser irradiation. Meanwhile, an experiment was also conducted in vitro to measure the tempreture history of a porcine skin specimen irradiated by a 1.319 μm laser. Predictions from the model included light distribution in the skin, temperature response and thermal damge level of the tissue. It was shown that the light distribution region was much larger than that of the incident laser at the wavelength of 1.319 μm, and the maximum value of the fluence rate located on the interior region of the skin, not on the surface. By comparing the calculated temperature curve with the experimentally recorded temperautre data, good agreement was shown betweeen them, which validated the numerical model. The model also indicated that the damage integral changed little when the temperature of skin tissue was lower than about 55 °C, after that, the integral increased rapidly and denatunation of the tissue would occur. Based on this model, we can further explore the damage mechanisms and trends for the skin and eye within the wavelength region of 1.3 μm to 1.4 μm, incorporating with in vivo experimental investigations.
2002-03-01
Surface Temperature and Polygraph Measures 19 References Cook , E. and Turpin , G. ( 1997 ). Differentiating orienting, startle, and defense responses... Turpin , 1997 ). The results of the present study also suggest that, in the forehead and periorbital region, the situation is complex. A multivariate...Facial Skin Surface Temperature and Polygraph Measures 3 areas would be differentially affected by participants’ fear-induced central and ANS responses to
A Study of Thermistor Performance within a Textile Structure.
Hughes-Riley, Theodore; Lugoda, Pasindu; Dias, Tilak; Trabi, Christophe L; Morris, Robert H
2017-08-05
Textiles provide an ideal structure for embedding sensors for medical devices. Skin temperature measurement is one area in which a sensor textile could be particularly beneficial; pathological skin is normally very sensitive, making the comfort of anything placed on that skin paramount. Skin temperature is an important parameter to measure for a number of medical applications, including for the early detection of diabetic foot ulcer formation. To this end an electronic temperature-sensor yarn was developed by embedding a commercially available thermistor chip into the fibres of a yarn, which can be used to produce a textile or a garment. As part of this process a resin was used to encapsulate the thermistor. This protects the thermistor from mechanical and chemical stresses, and also allows the sensing yarn to be washed. Building off preliminary work, the behaviour and performance of an encapsulated thermistor has been characterised to determine the effect of encapsulation on the step response time and absolute temperature measurements. Over the temperature range of interest only a minimal effect was observed, with step response times varying between 0.01-0.35 s. A general solution is presented for the heat transfer coefficient compared to size of the micro-pod formed by the encapsulation of the thermistor. Finally, a prototype temperature-sensing sock was produced using a network of sensing yarns as a demonstrator of a system that could warn of impending ulcer formation in diabetic patients.
Mathur, Neha; Glesk, Ivan; Buis, Arjan
2016-10-01
Monitoring of the interface temperature at skin level in lower-limb prosthesis is notoriously complicated. This is due to the flexible nature of the interface liners used impeding the required consistent positioning of the temperature sensors during donning and doffing. Predicting the in-socket residual limb temperature by monitoring the temperature between socket and liner rather than skin and liner could be an important step in alleviating complaints on increased temperature and perspiration in prosthetic sockets. In this work, we propose to implement an adaptive neuro fuzzy inference strategy (ANFIS) to predict the in-socket residual limb temperature. ANFIS belongs to the family of fused neuro fuzzy system in which the fuzzy system is incorporated in a framework which is adaptive in nature. The proposed method is compared to our earlier work using Gaussian processes for machine learning. By comparing the predicted and actual data, results indicate that both the modeling techniques have comparable performance metrics and can be efficiently used for non-invasive temperature monitoring. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Thermal stress analysis of space shuttle orbiter wing skin panel and thermal protection system
NASA Technical Reports Server (NTRS)
Ko, William L.; Jenkins, Jerald M.
1987-01-01
Preflight thermal stress analysis of the space shuttle orbiter wing skin panel and the thermal protection system (TPS) was performed. The heated skin panel analyzed was rectangular in shape and contained a small square cool region at its center. The wing skin immediately outside the cool region was found to be close to the state of elastic instability in the chordwise direction based on the conservative temperature distribution. The wing skin was found to be quite stable in the spanwise direction. The potential wing skin thermal instability was not severe enough to tear apart the strain isolation pad (SIP) layer. Also, the preflight thermal stress analysis was performed on the TPS tile under the most severe temperature gradient during the simulated reentry heating. The tensile thermal stress induced in the TPS tile was found to be much lower than the tensile strength of the TPS material. The thermal bending of the TPS tile was not severe enough to cause tearing of the SIP layer.
Hot bats: extreme thermal tolerance in a desert heat wave.
Bondarenco, Artiom; Körtner, Gerhard; Geiser, Fritz
2014-08-01
Climate change is predicted to increase temperature extremes and thus thermal stress on organisms. Animals living in hot deserts are already exposed to high ambient temperatures (T a) making them especially vulnerable to further warming. However, little is known about the effect of extreme heat events on small desert mammals, especially tree-roosting microbats that are not strongly protected from environmental temperature fluctuations. During a heat wave with record T as at Sturt National Park, we quantified the thermal physiology and behaviour of a single free-ranging little broad-nosed (Scotorepens greyii, henceforth Scotorepens) and two inland freetail bats (Mormopterus species 3, henceforth Mormopterus) using temperature telemetry over 3 days. On 11 and 13 January, maximum T a was ∼45.0 °C, and all monitored bats were thermoconforming. On 12 January 2013, when T a exceeded 48.0 °C, Scotorepens abandoned its poorly insulated roost during the daytime, whereas both Mormopterus remained in their better insulated roosts and were mostly thermoconforming. Maximum skin temperatures (T skin) ranged from 44.0 to 44.3 °C in Scotorepens and from 40.0 to 45.8 °C in Mormopterus, and these are the highest T skin values reported for any free-ranging bat. Our study provides the first evidence of extensive heat tolerance in free-ranging desert microbats. It shows that these bats can tolerate the most extreme T skin range known for mammals (3.3 to 45.8 °C) and delay regulation of T skin by thermoconforming over a wide temperature range and thus decrease the risks of dehydration and consequently death.
Sharma, Kavita; Ko, Eun Young; Assefa, Awraris D; Ha, Soyoung; Nile, Shivraj H; Lee, Eul Tai; Park, Se Won
2015-06-01
Heating effect on total phenol, flavonoids, antioxidant activity, and sugar content of six onion varieties has been quantitatively investigated to explore the effect of different temperatures. The onion varieties comprised one red-skinned variety, two white-skinned varieties, and three yellow-skinned varieties. The heating temperature was scanned at 80°C, 100°C, 120°C, and 150°C for 30 minutes each, and quantitative analysis was performed relative to the powdered onion at ambient temperature. Quercetin, glucosides and sugar content were analyzed using high-performance liquid chromatography. The total phenolic and antioxidant content increased in all six varieties. The total flavonoid levels showed a considerable change. On heating the onion samples at 120°C for 30 minutes, the red-skinned variety showed the highest level of total phenolic content [13712.67 ± 1034.85 μg of gallic acid equivalent/g dry weight (μg GAE/g DW)] and total flavonoids [3456.00 ± 185.82 μg of quercetin equivalents/g dry weight (μg Q/g DW)], whereas the content of total phenolics and total flavonoids were 13611.83 ± 341.61 μg GAE/g DW and 3482.87 ± 117.17 μg Q/g DW, respectively, for the yellow-skinned (Sunpower) variety. Quercetin and its glucoside contents increased up to 120°C and then decreased at 150°C, whereas the sugar content continuously decreased with heating. All cultivars showed the same pattern in the heating effect, and the predominant flavonoids were destroyed at higher temperatures. Therefore, it is improper to expose onion powder to a temperature higher than 120°C. Copyright © 2015. Published by Elsevier B.V.
Prediction of Skin Temperature Distribution in Cosmetic Laser Surgery
NASA Astrophysics Data System (ADS)
Ting, Kuen; Chen, Kuen-Tasnn; Cheng, Shih-Feng; Lin, Wen-Shiung; Chang, Cheng-Ren
2008-01-01
The use of lasers in cosmetic surgery has increased dramatically in the past decade. To achieve minimal damage to tissues, the study of the temperature distribution of skin in laser irradiation is very important. The phenomenon of the thermal wave effect is significant due to the highly focused light energy of lasers in very a short time period. The conventional Pennes equation does not take the thermal wave effect into account, which the thermal relaxation time (τ) is neglected, so it is not sufficient to solve instantaneous heating and cooling problem. The purpose of this study is to solve the thermal wave equation to determine the realistic temperature distribution during laser surgery. The analytic solutions of the thermal wave equation are compared with those of the Pennes equation. Moreover, comparisons are made between the results of the above equations and the results of temperature measurement using an infrared thermal image instrument. The thermal wave equation could likely to predict the skin temperature distribution in cosmetic laser surgery.
Deguines, C; Dégrugilliers, L; Ghyselen, L; Chardon, K; Bach, V; Tourneux, P
2013-03-01
Very-low-birth-weight (VLBW) neonates require regular nursing procedures with frequent opening of the incubator resulting in a decrease in incubator air temperature. This study was designed to assess changes in the thermal status of VLBW neonates according to the type of nursing care and incubator openings. Thirty-one VLBW neonates (mean gestational age: 28.7 ± 0.3 weeks of gestation) were included. Over a 10-day period, each opening of the incubator was recorded together with details about caregiving. Body temperature was recorded continuously, and door opening and closing events were recorded by a video camera. This study analysed 1,798 caregiving procedures with mean durations ranging from 6.2 ± 2.1 to 88.5 ± 33.4 min. Abdominal skin temperature decreased by up to 1.08°C/h for procedures such as tracheal intubation (p < 0.01). The temperature decrease was strongly correlated with the type of procedure (p < 0.01), incubator opening (p < 0.01) and procedure duration (p < 0.01). The procedure duration accounted for only 10% of the abdominal skin temperature change (p < 0.01). For VLBW neonates nursed in skin temperature servo-control incubators, the decrease in abdominal skin temperature during caregiving was correlated with the type of procedure, incubator opening modalities and procedure duration. These parameters should be considered to optimize the thermal management of VLBW neonates. ©2012 The Author(s)/Acta Paediatrica ©2012 Foundation Acta Paediatrica.
Temperature variation, bacterial diversity and fungal infection dynamics in the amphibian skin.
Longo, Ana V; Zamudio, Kelly R
2017-09-01
Host-associated bacterial communities on the skin act as the first line of defence against invading pathogens. Yet, for most natural systems, we lack a clear understanding of how temperature variability affects structure and composition of skin bacterial communities and, in turn, promotes or limits the colonization of opportunistic pathogens. Here, we examine how natural temperature fluctuations might be related to changes in skin bacterial diversity over time in three amphibian populations infected by the pathogenic fungus Batrachochytrium dendrobatidis (Bd). Our focal host species (Eleutherodactylus coqui) is a direct-developing frog that has suffered declines at some populations in the last 20 years, while others have not experienced any changes. We quantified skin bacterial alpha- and beta-diversity at four sampling time points, a period encompassing two seasons and ample variation in natural infections and environmental conditions. Despite the different patterns of infection across populations, we detected an overall increase in bacterial diversity through time, characterized by the replacement of bacterial operational taxonomic units (OTUs). Increased frog body temperatures possibly allowed the colonization of bacteria as well as the recruitment of a subset of indicator OTUs, which could have promoted the observed changes in diversity patterns. Our results suggest that natural environmental fluctuations might be involved in creating opportunities for bacterial replacement, potentially attenuating pathogen transmission and thus contributing to host persistence in E. coqui populations. © 2017 John Wiley & Sons Ltd.
Isolation of two biologically active cell surface proteins from Brucella abortus by chromatofocusing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tabatabai, L.B.; Deyoe, B.L.
1983-01-01
Brucella abortus contains a group of immunogenic cell surface proteins which have potential value as a vaccine or as a diagnostic reagent for the prevention and diagnosis of bovine brucellosis. Under nondenaturing conditions, these proteins range in molecular weight from 10,000-124,000, as determined by high performance liquid chromatography (HPLC) on TSK 3000sw. By analytical isoelectrofocusing, 6 major protein bands could be distinguished with pI's ranging from 4.0 to 6.0 and 3 additional major proteins with pI's of 7.5, 9.5, and 10. By chromatofocusing on Polybuffer Exchanger 94 with a pH gradient from 6-4, two of the six proteins from pImore » 4-6 were separated, a pI 4.9 and a pI 4.7 protein; a third fraction contained the high pI proteins. The former two proteins were homogeneous by analytical isoelectrofocusing, and a molecular weight of 54,000 daltons was found for both protein species by HPLC on TSK 3000sw. The pI 4-6 and not the pI 9.5 and 10 proteins, could be radiolabeled when intact cells were radioiodinated with diazotized (/sup 125/I)-iodosulfanilic acid. Biological activity of the proteins as assessed in lemmings indicated that immunization with the pI 4.7 and 4.9 proteins afforded better protection against experimental brucellosis than immunization with the high pI proteins. These results support our view that a single surface protein may be sufficient for the prevention of experimental brucellosis.« less
He, S L; Wang, J H; Ji, P
2018-03-01
To validate the Pain Resilience Scale (PRS) for use in Chinese patients with temporomandibular disorders (TMD) pain. According to international guidelines, the original PRS was first translated and cross-culturally adapted to formulate the Chinese version of PRS (PRS-C). A total of 152 patients with TMD pain were recruited to complete series of questionnaires. Reliability of the PRS-C was investigated using internal consistency and test-retest reliability. Validity of the PRS-C was calculated using cross-cultural validity and convergent validity. Cross-cultural validity was evaluated by examining the confirmatory factor analysis (CFA). And convergent validity was examined through correlating the PRS-C scores with scores of 2 commonly used pain-related measures (the Connor-Davidson Resilience Scale [CD-RISC] and the Tampa Scale for Kinesiophobia for Temporomandibular Disorders [TSK-TMD]). The PRS-C had a high internal consistency (Cronbach's alpha = 0.92) and good test-retest reliability (intra-class correlation coefficient [ICC] = 0.81). The CFA supported a 2-factor model for the PRS-C with acceptable fit to the data. The fit indices were chi-square/DF = 2.21, GFI = 0.91, TLI = 0.97, CFI = 0.98 and RMSEA = 0.08. As regards convergent validity, the PRS-C evidenced moderate-to-good relationships with the CD-RISC and the TSK-TMD. The PRS-C shows good psychometric properties and could be considered as a reliable and valid measure to evaluate pain-related resilience in patients with TMD pain. © 2017 John Wiley & Sons Ltd.
Stretchable silicon nanoribbon electronics for skin prosthesis.
Kim, Jaemin; Lee, Mincheol; Shim, Hyung Joon; Ghaffari, Roozbeh; Cho, Hye Rim; Son, Donghee; Jung, Yei Hwan; Soh, Min; Choi, Changsoon; Jung, Sungmook; Chu, Kon; Jeon, Daejong; Lee, Soon-Tae; Kim, Ji Hoon; Choi, Seung Hong; Hyeon, Taeghwan; Kim, Dae-Hyeong
2014-12-09
Sensory receptors in human skin transmit a wealth of tactile and thermal signals from external environments to the brain. Despite advances in our understanding of mechano- and thermosensation, replication of these unique sensory characteristics in artificial skin and prosthetics remains challenging. Recent efforts to develop smart prosthetics, which exploit rigid and/or semi-flexible pressure, strain and temperature sensors, provide promising routes for sensor-laden bionic systems, but with limited stretchability, detection range and spatio-temporal resolution. Here we demonstrate smart prosthetic skin instrumented with ultrathin, single crystalline silicon nanoribbon strain, pressure and temperature sensor arrays as well as associated humidity sensors, electroresistive heaters and stretchable multi-electrode arrays for nerve stimulation. This collection of stretchable sensors and actuators facilitate highly localized mechanical and thermal skin-like perception in response to external stimuli, thus providing unique opportunities for emerging classes of prostheses and peripheral nervous system interface technologies.
The effect of acclimatization and ambient temperature on heat withdrawal threshold in rats.
Vítková, J; Loučka, M; Boček, J; Vaculín, S
2015-01-01
Nociception in rats is frequently measured in terms of latency of withdrawal reaction to radiant heat (thermal nociceptive threshold). The aim of this study was to determine how much housing acclimatization and ambient temperature affect the results of thermal pain threshold testing. All experiments used adult male Wistar rats. Thermal pain thresholds were tested using the radiant heat withdrawal reaction at three different body sites: forepaws, hind paws and tail. Skin temperature was measured using an Infrared thermometer and ambient temperature was set at 18, 20, 24 or 26 °C. The results demonstrate that (1) thermal pain threshold was inversely related to both ambient and skin temperature; (2) housing acclimatization and repeated testing had no effect on nociceptive thresholds at any of the three body sites; (3) a resting, cranio-caudal distribution, of nociceptive sensitivity was observed; (4) hind paws and tail were more sensitive to changes of skin and ambient temperature than forepaws. These findings show the importance of recording laboratory conditions in experiments and their influence on results. © 2014 European Pain Federation - EFIC®
PHYSIOLOGICAL RESPONSE PATTERNS IN CARDIAC PATIENTS,
CARDIOVASCULAR DISEASES, ETIOLOGY), HEART, DISEASES, ELECTROENCEPHALOGRAPHY, GALVANIC SKIN RESPONSE, PULSE RATE, BODY TEMPERATURE, SKIN(ANATOMY...HYPERTENSION, ATHEROSCLEROSIS , RHEUMATIC DISEASES, EMOTIONS, REACTION(PSYCHOLOGY), PERSONALITY, PSYCHOLOGY, PATHOLOGY, MEDICAL EXAMINATION
Evidence against a 40 degrees C core temperature threshold for fatigue in humans.
Ely, Brett R; Ely, Matthew R; Cheuvront, Samuel N; Kenefick, Robert W; Degroot, David W; Montain, Scott J
2009-11-01
Evidence suggests that core temperatures of approximately 40 degrees C can induce fatigue, although this may be confounded by coincident elevations in skin temperatures and maximal cardiovascular strain. In an observational field study to examine core temperature threshold for fatigue, we investigated whether running performance is impaired when rectal temperature (T(re)) is >40 degrees C and skin temperature remains modest. Seventeen competitive runners (7/10 women/men: 8 km best 1,759 +/- 78/1,531 +/- 60 s) completed 8-km track time trials in cool (WBGT approximately 13 degrees C; n = 6), warm (WBGT approximately 27 degrees C; n = 4), or both (n = 7) conditions. T(re), chest skin temperature, and heart rate were logged continuously; elapsed time was recorded every 200 m. Running velocity for T(re) >40 degrees C was compared with that for T(re) <40 degrees C for each runner. Changes in running velocity over the last 600 m were compared between runners with T(re) >40 degrees C and <40 degrees C. Twelve runners achieved T(re) >40.0 degrees C with >or=600 m remaining (range 600-3,400 m). Average running velocity for T(re) <40 degrees C (282 +/- 27 m/min) was not different from that for T(re) >40 degrees C (279 +/- 28 m/min; P = 0.82). There were no differences in running velocity during the final 600 m between runners with final T(re) >40 degrees C or <40 degrees C (P = 0.16). Chest skin temperature ranged from 30 to 34 degrees C, and heart rate was >95% of age-predicted maximum. Our observation that runners were able to sustain running velocity despite T(re) >40 degrees C is evidence against 40 degrees C representing a "critical" core temperature limit to performance.
The relationship between radiant heat, air temperature and thermal comfort at rest and exercise.
Guéritée, Julien; Tipton, Michael J
2015-02-01
The aims of the present work were to investigate the relationships between radiant heat load, air velocity and body temperatures with or without coincidental exercise to determine the physiological mechanisms that drive thermal comfort and thermoregulatory behaviour. Seven male volunteers wearing swimming trunks in 18°C, 22°C or 26°C air were exposed to increasing air velocities up to 3 m s(-1) and self-adjusted the intensity of the direct radiant heat received on the front of the body to just maintain overall thermal comfort, at rest or when cycling (60 W, 60 rpm). During the 30 min of the experiments, skin and rectal temperatures were continuously recorded. We hypothesized that mean body temperature should be maintained stable and the intensity of the radiant heat and the mean skin temperatures would be lower when cycling. In all conditions, mean body temperature was lower when facing winds of 3 m s(-1) than during the first 5 min, without wind. When facing winds, in all but the 26°C air, the radiant heat was statistically higher at rest than when exercising. In 26°C air mean skin temperature was lower at rest than when exercising. No other significant difference was observed. In all air temperatures, high correlation coefficients were observed between the air velocity and the radiant heat load. Other factors that we did not measure may have contributed to the constant overall thermal comfort status despite dropping mean skin and body temperatures. It is suggested that the allowance to behaviourally adjust the thermal environment increases the tolerance of cold discomfort. Copyright © 2014 Elsevier Inc. All rights reserved.
Oizumi, Takuya; Laakso, Ilkka; Hirata, Akimasa; Fujiwara, Osamu; Watanabe, Soichi; Taki, Masao; Kojima, Masami; Sasaki, Hiroshi; Sasaki, Kazuyuki
2013-07-01
The eye is said to be one of the most sensitive organs to microwave heating. According to previous studies, the possibility of microwave-induced cataract formation has been experimentally investigated in rabbit and monkey eyes, but not for the human eye due to ethical reasons. In the present study, the temperature elevation in the lens, the skin around the eye and the core temperature of numerical human and rabbit models for far-field and near-field exposures at 2.45 GHz are investigated. The temperature elevations in the human and rabbit models were compared with the threshold temperatures for inducing cataracts, thermal pain in the skin and reversible health effects such as heat exhaustion or heat stroke. For plane-wave exposure, the core temperature elevation is shown to be essential both in the human and in the rabbit models as suggested in the international guidelines and standards. For localised exposure of the human eye, the temperature elevation of the skin was essential, and the lens temperature did not reach its threshold for thermal pain. On the other hand, the lens temperature elevation was found to be dominant for the rabbit eye.
Nakata, Shogo; Arie, Takayuki; Akita, Seiji; Takei, Kuniharu
2017-03-24
Real-time daily healthcare monitoring may increase the chances of predicting and diagnosing diseases in their early stages which, currently, occurs most frequently during medical check-ups. Next-generation noninvasive healthcare devices, such as flexible multifunctional sensor sheets designed to be worn on skin, are considered to be highly suitable candidates for continuous real-time health monitoring. For healthcare applications, acquiring data on the chemical state of the body, alongside physical characteristics such as body temperature and activity, are extremely important for predicting and identifying potential health conditions. To record these data, in this study, we developed a wearable, flexible sweat chemical sensor sheet for pH measurement, consisting of an ion-sensitive field-effect transistor (ISFET) integrated with a flexible temperature sensor: we intend to use this device as the foundation of a fully integrated, wearable healthcare patch in the future. After characterizing the performance, mechanical flexibility, and stability of the sensor, real-time measurements of sweat pH and skin temperature are successfully conducted through skin contact. This flexible integrated device has the potential to be developed into a chemical sensor for sweat for applications in healthcare and sports.
Kobayashi, Makoto
2016-04-01
We present a 21-year-old female with Horner syndrome due to spinal cord infarction. In this patient, infrared thermography revealed a hemibody skin temperature increase followed by excessive focal decreases, indicating skin vasomotor hemiparesis and overactivity.
Contact Force Compensated Thermal Stimulators for Holistic Haptic Interfaces.
Sim, Jai Kyoung; Cho, Young-Ho
2016-05-01
We present a contact force compensated thermal stimulator that can provide a consistent tempera- ture sensation on the human skin independent of the contact force between the thermal stimulator and the skin. Previous passive thermal stimulators were not capable of providing a consistent tem- perature on the human skin even when using identical heat source voltage due to an inconsistency of the heat conduction, which changes due to the force-dependent thermal contact resistance. We propose a force-based feedback method that monitors the contact force and controls the heat source voltage according to this contact force, thus providing consistent temperature on the skin. We composed a heat circuit model equivalent to the skin heat-transfer rate as it is changed by the contact forces; we obtained the optimal voltage condition for the constant skin heat-transfer rate independent of the contact force using a numerical estimation simulation tool. Then, in the experiment, we heated real human skin at the obtained heat source voltage condition, and investigated the skin heat transfer-rate by measuring the skin temperature at various times at different levels of contact force. In the numerical estimation results, the skin heat-transfer rate for the contact forces showed a linear profile in the contact force range of 1-3 N; from this profile we obtained the voltage equation for heat source control. In the experimental study, we adjusted the heat source voltage according to the contact force based on the obtained equation. As a result, without the heat source voltage control for the contact forces, the coefficients of variation (CV) of the skin heat-transfer rate in the contact force range of 1-3 N was found to be 11.9%. On the other hand, with the heat source voltage control for the contact forces, the CV of the skin heat-transfer rate in the contact force range of 1-3 N was found to be barely 2.0%, which indicate an 83.2% improvement in consistency compared to the skin heat-transfer rate without the heat source voltage control. The present technique provides a consistent temperature sensation on the human skin independent of the body movement environment; therefore, it has high potential for use in holistic haptic interfaces that have thermal displays.
Study of the effect of temperature on the optical properties of Latin skins
NASA Astrophysics Data System (ADS)
Quistián-Vázquez, Brenda; Morales-Cruzado, Beatriz; Sarmiento-Gómez, Erick; Pérez-Gutiérrez, Francisco G.
2017-02-01
Photodynamic therapy (PDT) is a very effective technique for treatment of certain types of cancer, among the most common, skin cancer. PDT requires the presence of three elements: the photosensitizer, light and oxygen. Penetration depth of light into the tumor depends on both the characteristics of the tissue to be treated and the wavelength. As the light dose to be delivered in each lesion depends on the optical properties of the tissue, all the effects that change these properties should be considered in order to choose suitable doses. There are some studies that have determined the maximum dose of radiation tolerated for certain types of skin, but the influence of the temperature on the optical properties, especially for darker skin types, remains unknown. In this study, we analyzed the optical properties of skin in vivo of different Latin volunteers in order to study the influence of the temperature on the optical properties and thereby to define more precisely the dose of light to be received by each patient in a personalized way. The optical properties of skin in vivo were investigated using an optical system that included an integrating sphere, a tungsten lamp and a spectrophotometer. Such experimental set up-allowed to obtain spectra reflectance of various volunteers and from this measurement, the absorption coefficient was recovered by Inverse Adding Doubling (IAD) program.
Hammond, L E; Cuttell, S; Nunley, P; Meyler, J
2014-01-01
This study explored whether anthropometric measures influence magnitude of skin cooling following exposure to whole body cryotherapy (WBC). Height, weight, body fat percentage, and lean mass were measured in 18 male and 14 female participants. Body surface area, body surface area to mass ratio, body mass index, fat-free mass index, and fat mass index were calculated. Thermal images were captured before and after WBC (-60°C for 30 seconds, -110°C for 2 minutes). Skin temperature was measured at the chest, arm, thigh, and calf. Mean skin temperature before and after WBC and change in mean skin temperature (ΔT sk) were calculated. ΔT sk was significantly greater in females (12.07 ± 1.55°C) than males (10.12 ± 1.86°C; t(30) = -3.09, P = .004). A significant relationship was observed between body fat percentage and ΔT sk in the combined dataset (P = .002, r = .516) and between fat-free mass index and ΔT sk in males (P = .005, r = .622). No other significant associations were found. Skin response of individuals to WBC appears to depend upon anthropometric variables and sex, with individuals with a higher adiposity cooling more than thinner individuals. Effects of sex and anthompometrics should be considered when designing WBC research or treatment protocols.
Hammond, L. E.; Cuttell, S.; Nunley, P.; Meyler, J.
2014-01-01
This study explored whether anthropometric measures influence magnitude of skin cooling following exposure to whole body cryotherapy (WBC). Height, weight, body fat percentage, and lean mass were measured in 18 male and 14 female participants. Body surface area, body surface area to mass ratio, body mass index, fat-free mass index, and fat mass index were calculated. Thermal images were captured before and after WBC (−60°C for 30 seconds, −110°C for 2 minutes). Skin temperature was measured at the chest, arm, thigh, and calf. Mean skin temperature before and after WBC and change in mean skin temperature (ΔT sk) were calculated. ΔT sk was significantly greater in females (12.07 ± 1.55°C) than males (10.12 ± 1.86°C; t(30) = −3.09, P = .004). A significant relationship was observed between body fat percentage and ΔT sk in the combined dataset (P = .002, r = .516) and between fat-free mass index and ΔT sk in males (P = .005, r = .622). No other significant associations were found. Skin response of individuals to WBC appears to depend upon anthropometric variables and sex, with individuals with a higher adiposity cooling more than thinner individuals. Effects of sex and anthompometrics should be considered when designing WBC research or treatment protocols. PMID:25061612