Sample records for slide agglutination method

  1. Typing of Haemophilus influenzae by Coagglutination and Conventional Slide Agglutination

    PubMed Central

    Shively, Roxanne G.; Shigel, Janet T.; Peterson, Ellena M.; De La Maza, Luis M.

    1981-01-01

    Coagglutination was compared with conventional slide agglutination for the typing of 297 clinical isolates of Haemophilus sp. A 100% correlation was found with the H. influenzae type b isolates. Coagglutination showed no false-positive reactions with the nontypable strains of H. influenzae and H. parainfluenzae isolates; however, conventional slide agglutination exhibited many false-positive and non-interpretable reactions. PMID:6977555

  2. Studying red blood cell agglutination by measuring membrane viscosity with optical tweezers

    NASA Astrophysics Data System (ADS)

    Fernandes, Heloise P.; Fontes, Adriana; de Thomaz, André A.; Barbosa, Luiz C.; Barjas-Castro, Maria L.; Cesar, Carlos L.

    2007-09-01

    The red blood cell (RBC) viscoelastic membrane contains proteins and glycoproteins embedded in a fluid lipid bilayer that are responsible for cell agglutination. Manipulating RBCs rouleaux with a double optical tweezers, we observed that the cells slide easily one over the others but are strongly connected by their edges. An explanation for this behavior could be the fact that when the cells slide one over the others, proteins are dragged through the membrane. It confers to the movement a viscous characteristic that is dependent of the velocity between the RBCs and justifies why is so easy to slide them apart. Therefore, in a first step of this work, by measuring the force as a function of the relative velocity between two cells, we confirmed this assumption and used this viscous characteristic of the RBC rouleaux to determine the apparent membrane viscosity of the cell. As this behavior is related to the proteins interactions, we can use the apparent membrane viscosity to obtain a better understanding about cell agglutination. Methods related to cell agglutination induced by antigen-antibody interactions are the basis of most of tests used in transfusion centers. Then, in a second step of this work, we measured the apparent membrane viscosity using antibodies. We observed that this methodology is sensitive to different kinds of bindings between RBCs. Better comprehension of the forces and bindings between RBCs could improve the sensibility and specificity of the hemagglutination reactions and also guides the development of new potentiator substances.

  3. False-positive cryptococcal antigen latex agglutination caused by disinfectants and soaps.

    PubMed Central

    Blevins, L B; Fenn, J; Segal, H; Newcomb-Gayman, P; Carroll, K C

    1995-01-01

    Five disinfectants or soaps were tested to determine if any could be responsible for false-positive results obtained with the Latex-Crypto Antigen Detection System kit (Immuno-Mycologics, Inc., Norman, Okla.). Three disinfectants or soaps (Derma soap, 7X, and Bacdown) produced false-positive agglutination after repeated washing of ring slides during testing of a known negative cerebrospinal fluid specimen. PMID:7650214

  4. Development of a simple and rapid method for the specific identification of organism causing anthrax by slide latex agglutination.

    PubMed

    Sumithra, T G; Chaturvedi, V K; Gupta, P K; Sunita, S C; Rai, A K; Kutty, M V H; Laxmi, U; Murugan, M S

    2014-05-01

    A specific latex agglutination test (LAT) based on anti-PA (protective antigen) antibodies having detection limit of 5 × 10(4) formalin treated Bacillus anthracis cells or 110 ng of PA was optimized in this study. The optimized LAT could detect anthrax toxin in whole blood as well as in serum from the animal models of anthrax infection. The protocol is a simple and promising method for the specific detection of bacteria causing anthrax under routine laboratory, as well as in field, conditions without any special equipments or expertise. The article presents the first report of a latex agglutination test for the specific identification of the cultures of bacteria causing anthrax. As the test is targeting one of anthrax toxic protein (PA), this can also be used to determine virulence of suspected organisms. At the same time, the same LAT can be used directly on whole blood or sera samples under field conditions for the specific diagnosis of anthrax. © 2013 The Society for Applied Microbiology.

  5. Sensitivity and specificity of typhoid fever rapid antibody tests for laboratory diagnosis at two sub-Saharan African sites

    PubMed Central

    Keddy, Karen H; Sooka, Arvinda; Letsoalo, Maupi E; Hoyland, Greta; Chaignat, Claire Lise; Morrissey, Anne B; Crump, John A

    2011-01-01

    Abstract Objective To evaluate three commercial typhoid rapid antibody tests for Salmonella Typhi antibodies in patients suspected of having typhoid fever in Mpumalanga, South Africa, and Moshi, United Republic of Tanzania. Methods The diagnostic accuracy of Cromotest® (semiquantitative slide agglutination and single tube Widal test), TUBEX® and Typhidot® was assessed against that of blood culture. Performance was modelled for scenarios with pretest probabilities of 5% and 50%. Findings In total 92 patients enrolled: 53 (57.6%) from South Africa and 39 (42.4%) from the United Republic of Tanzania. Salmonella Typhi was isolated from the blood of 28 (30.4%) patients. The semiquantitative slide agglutination and single-tube Widal tests had positive predictive values (PPVs) of 25.0% (95% confidence interval, CI: 0.6–80.6) and 20.0% (95% CI: 2.5–55.6), respectively. The newer typhoid rapid antibody tests had comparable PPVs: TUBEX®, 54.1% (95% CI: 36.9–70.5); Typhidot® IgM, 56.7% (95% CI: 37.4–74.5); and Typhidot® IgG, 54.3% (95% CI: 36.6–71.2). For a pretest probability of 5%, PPVs were: TUBEX®, 11.0% (95% CI: 6.6–17.9); Typhidot® IgM, 9.1% (95% CI: 5.8–14.0); and Typhidot® IgG, 11.0% (6.3–18.4). For a pretest probability of 50%, PPVs were: TUBEX®, 70.2% (95% CI: 57.3–80.5); Typhidot® IgM, 65.6% (95% CI: 54.0–75.6); and Typhidot® IgG, 70.0% (95% CI: 56.0–81.1). Conclusion Semiquantitative slide agglutination and single-tube Widal tests performed poorly. TUBEX® and Typhidot® may be suitable when pretest probability is high and blood cultures are unavailable, but their performance does not justify deployment in routine care settings in sub-Saharan Africa. PMID:21897484

  6. [Evaluation of the usefulness of the agglutination test with Mangifera indica extract for the identification of pathogenic Yersinia enterocolitica strains].

    PubMed

    Kałuzewski, S; Gierczyński, R; Szych, J; Jagielski, M

    1997-01-01

    The study was performed on 137 Y. enterocolitica strains belonging to various serological groups, including 75 03 group strains isolated form human clinical material. The agglutination test on slides was carried out on this strains using Mangifera indica extract of own production. Agglutinating preparation obtained from the seeds of M. indica agglutinated Y. enterocolitica organisms possessing the pVY plasmid and CRMOX+ phenotype in dilutions to 1.56 micrograms/ml. In identification tests conducted parallelly agglutination solution was used in concentrations of 100 and 10 micrograms/ml. All clones of Y. enterocolitica from O3 group from cultures at 37 degrees C and with CRMOX+ phenotype possessing the pVY plasmid were agglutinated by the extract. Agglutination failed to develop in the cultures of these clones incubated at 25 degrees C. Yersinia clones not containing the pVY plasmid with CRMOX- phenotype were resistant to agglutination. The virulence plasmid was found in 44 out of 75 strains of Y. enterocolitica O3 and was identified by restriction analysis after plasmid DNA digestion with Eco RI enzyme. The obtained results agreed with those of Wauters et al. in 1995 and confirmed the opinion of these authors on the usefulness of the test with M. indica agglutinin for the identification of virulent Y. enterocolitica strains.

  7. Evaluation of four slide test kits for the detection of human chorionic gonadotropin in urine

    PubMed Central

    Dietrich, Michael; French, J. A.

    1974-01-01

    Three “indirect-type” slide tests utilizing the principle of hemagglutination inhibition and one new “direct-type” slide test employing direct agglutination were evaluated for their sensitivity in detecting human chorionic gonadotropin (HCG) in urine. The results of positive tests in a group of woman in very early pregnancy were correlated with the “days after last menses”. In this series the direct slide test was the most accurate. A control must be used with each direct test to indicate interfering substances and when such are present a different test must be used. All tests were found to be of the relative sensitivity stated by the manufacturer. PMID:4851924

  8. Serodiagnosis of infectious mononucleosis with a bovine erythrocyte glycoprotein.

    PubMed

    Fletcher, M A; Klimas, N G; Latif, Z A; Caldwell, K E

    1983-09-01

    A glycoprotein from bovine erythrocyte membrane was evaluated in two immunoassays as a reagent for the serodiagnosis of infectious mononucleosis (IM). We previously reported that a partially purified preparation of this glycoprotein, when attached to latex beads, agglutinated in the presence of IM heterophile antibody. In the present study, we used a highly purified form of the glycoprotein both as an agglutinating reagent, covalently bound to latex, and in a solid-phase sandwich-type radioimmunoassay (RIA) for IM antibody detection in a larger population of patients. We tested serum samples from college students with symptoms suggestive of IM with the latex reagent (143 samples) and with the RIA (245 samples). Correlation of these two tests, both with each other and with the classical differentially absorbed, agglutination tests for Paul-Bunnell antibody in IM sera, using fresh sheep or horse cells, was excellent (greater than 97% agreement). The new tests also corresponded in most cases with a rapid, unabsorbed preserved horse erythrocyte slide test. However, in this study of 245 samples, both apparent false-positives (5 samples) and apparent false-negatives (3 samples) were observed with this slide test. In conclusion, we found that the bovine glycoprotein as a reagent can facilitate the diagnosis of IM, giving results comparable to those with erythrocyte agglutination tests on differentially absorbed sera. The advantages are ease and speed of performance (latex test), potential for automation (RIA test), stability and uniformity of the glycoprotein reagent (latex and RIA tests), and most importantly, the ability to use unabsorbed sera (latex and RIA tests).

  9. Evaluation of a new automated instrument for pretransfusion testing.

    PubMed

    Morelati, F; Revelli, N; Maffei, L M; Poretti, M; Santoro, C; Parravicini, A; Rebulla, P; Cole, R; Sirchia, G

    1998-10-01

    A number of automated devices for pretransfusion testing have recently become available. This study evaluated a fully automated device based on column agglutination technology (AutoVue System, Ortho, Raritan, NJ). Some 6747 tests including forward and reverse ABO group, Rh type and phenotype, antibody screen, autocontrol, and crossmatch were performed on random samples from 1069 blood donors, 2063 patients, and 98 newborns and cord blood. Also tested were samples from 168 immunized patients and 53 donors expressing weak or variant A and D antigens. Test results and technician times required for their performance were compared with those obtained by standard methods (manual column agglutination technology, slide, semiautomatic handler). No erroneous conclusions were found in regard to the 5028 ABO group and Rh type or phenotype determinations carried out with the device. The device rejected 1.53 percent of tests for sample inadequacy. Of the remaining 18 tests with discrepant results found with the device and not confirmed with the standard methods, 6 gave such results because of mixed-field reactions, 10 gave negative results with A2 RBCs in reverse ABO grouping, and 2 gave very weak positive reactions in antibody screening and crossmatching. In the samples from immunized patients, the device missed one weak anti-K, whereas standard methods missed five weak antibodies. In addition, 48, 34, and 31 of the 53 weak or variant antigens were detected by the device, the slide method, and the semiautomated handler, respectively. Technician time with the standard methods was 1.6 to 7 times higher than that with the device. The technical performance of the device compared favorably with that of standard methods, with a number of advantages, including in particular the saving of technician time. Sample inadequacy was the most common cause of discrepancy, which suggests that standardization of sample collection can further improve the performance of the device.

  10. Updated Campylobacter jejuni capsule PCR multiplex typing system and its application to clinical isolates from south and southeast Asia

    USDA-ARS?s Scientific Manuscript database

    Campylobacter jejuni produces a polysaccharide capsule that is the major determinant of the Penner serotyping scheme. This passive slide agglutination typing system was developed in the early 1980’s and was recognized for over two decades as gold standard for C. jejuni typing. A preliminary multiple...

  11. Cross-reactions in Legionella antisera with Bordetella pertussis strains.

    PubMed Central

    Benson, R F; Thacker, W L; Plikaytis, B B; Wilkinson, H W

    1987-01-01

    While preparing slide agglutination test antisera and immunofluorescence conjugates for the identification of Legionella species and serogroups, we found that several of the reagents cross-reacted with Bordetella pertussis strains. To determine the extent of this problem and to estimate the specificity of Legionella reagents, we tested slide agglutination test antisera against 22 species and 35 serogroups with 92 bacterial strains representing 19 genera. The only cross-reactions observed were with Legionella pneumophila serogroup 10, L. maceachernii, L. gormanii, and L. feeleii serogroup 1 antisera and 4 of 10 B. pertussis strains. Nineteen conjugates, previously available from the Centers for Disease Control but no longer distributed as reference reagents, were tested with the four cross-reactive B. pertussis strains. Two conjugates, L. micdadei and L. wadsworthii, stained three of the B. pertussis strains at a fluorescence intensity of greater than or equal to 3+. All cross-reactions were removed from the antisera and conjugates by absorption with the cross-reacting strain without diminishing the homologous reaction. Special emphasis should be placed on the identification and removal of cross-reactions in Legionella reagents with strains that have similar morphologic and growth characteristics. PMID:2883198

  12. Evaluation of new indigenous “point-of-care” ABO and Rh grouping device

    PubMed Central

    Tiwari, Aseem Kumar; Setya, Divya; Aggarwal, Geet; Arora, Dinesh; Dara, Ravi C.; Ratan, Ankita; Bhardwaj, Gunjan; Acharya, Devi Prasad

    2018-01-01

    BACKGROUND: Erycard 2.0 is a “point-of-care” device that is primarily being used for patient blood grouping before transfusion. MATERIALS AND METHODS: Erycard 2.0 was compared with conventional slide technology for accuracy and time taken for ABO and Rh forward grouping result with column agglutination technology (CAT) being the gold standard. Erycard 2.0 as a device was also evaluated for its stability under different storage conditions and stability of result till 48 h. In addition, grouping of hemolyzed samples was also tested with Erycard 2.0. Ease of use of Erycard 2.0 was evaluated with a survey among paramedical staff. RESULTS: Erycard 2.0 demonstrated 100% concordance with CAT as compared with slide technique (98.9%). Mean time taken per test by Erycard 2.0 and slide technique was 5.13 min and 1.7 min, respectively. After pretesting storage under different temperature and humidity conditions, Erycard 2.0 did not show any deviation from the result. The result did not change even after 48 h of testing and storage under room temperature. 100% concordance was recorded between pre- and post-hemolyzed blood grouping. Ease of use survey revealed that Erycard 2.0 was more acceptable to paramedical staff for its simplicity, objectivity, and performance than conventional slide technique. CONCLUSION: Erycard 2.0 can be used as “point-of-care” device for blood donor screening for ABO and Rh blood group and can possibly replace conventional slide technique. PMID:29403211

  13. Evaluation of a surface plasmon resonance imaging-based multiplex O-antigen serogrouping for Escherichia coli using eleven major serotypes of Shiga -toxin-producing E. coli.

    PubMed

    Nakano, Satoshi; Nagao, Miki; Yamasaki, Tomomi; Morimura, Hiroyuki; Hama, Natsuki; Iijima, Yoshio; Shinomiya, Hiroto; Tanaka, Michio; Yamamoto, Masaki; Matsumura, Yasufumi; Miyake, Shiro; Ichiyama, Satoshi

    2018-06-01

    The early detection of Shiga toxin-producing Escherichia coli (STEC) is important for early diagnosis and preventing the spread of STEC. Although the confirmatory test for STEC should be based on the detection of Shiga toxin using molecular analysis, isolation permits additional characterization of STEC using a variety of methods, including O:H serotyping. The conventional slide agglutination O-antigen serogrouping used in many clinical laboratories is laborious and time-consuming. Surface plasmon resonance (SPR)-based immunosensors are commonly used to investigate a large variety of bio-interactions such as antibody/antigen, peptide/antibody, DNA/DNA, and antibody/bacteria interactions. SPR imaging (SPRi) is characterized by multiplexing capabilities for rapidly screening (approximately 100 to several hundred sensorgrams in parallel) molecules. SPRi-based O-antigen serogrouping method for STEC was recently developed by detecting the interactions between O-antigen-specific antibodies and bacterial cells themselves. The aim of this study was to evaluate its performance for E. coli serogrouping using clinical STEC isolates by comparing the results of slide agglutination tests. We tested a total of 188 isolates, including O26, O45, O91, O103, O111, O115, O121, O128, O145, O157, and O159. The overall sensitivity of SPRi-based O-antigen serogrouping was 98.9%. Only two O157 isolates were misidentified as nontypeable and O121. The detection limits of all serotypes were distributed between 1.1 × 10 6 and 17.6 × 10 6  CFU/ml. Pulsed-field gel electrophoresis (PFGE) revealed the heterogeneity of the examined isolates. In conclusion, SPRi is a useful method for the O-antigen serogrouping of STEC isolates, but the further evaluation of non-O157 minor serogroups is needed. Copyright © 2018 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  14. Measurement of RBC agglutination with microscopic cell image analysis in a microchannel chip.

    PubMed

    Cho, Chi Hyun; Kim, Ju Yeon; Nyeck, Agnes E; Lim, Chae Seung; Hur, Dae Sung; Chung, Chanil; Chang, Jun Keun; An, Seong Soo A; Shin, Sehyun

    2014-01-01

    Since Landsteiner's discovery of ABO blood groups, RBC agglutination has been one of the most important immunohematologic techniques for ABO and RhD blood groupings. The conventional RBC agglutination grading system for RhD blood typings relies on macroscopic reading, followed by the assignment of a grade ranging from (-) to (4+) to the degree of red blood cells clumping. However, with the new scoring method introduced in this report, microscopically captured cell images of agglutinated RBCs, placed in a microchannel chip, are used for analysis. Indeed, the cell images' pixel number first allows the differentiation of agglutinated and non-agglutinated red blood cells. Finally, the ratio of agglutinated RBCs per total RBC counts (CRAT) from 90 captured images is then calculated. During the trial, it was observed that the agglutinated group's CRAT was significantly higher (3.77-0.003) than that of the normal control (0). Based on these facts, it was established that the microchannel method was more suitable for the discrimination between agglutinated RBCs and non-agglutinated RhD negative, and thus more reliable for the grading of RBCs agglutination than the conventional method.

  15. Leptospira and Brucella antibodies in collared anteaters (Tamandua tetradactyla) in Brazilian zoos.

    PubMed

    Sales, Indiara dos Santos; Folly, Márcio Manhães; Garcia, Luize Néli Nunes; Ramos, Tatiane Mendes Varela; da Silva, Mariana Cristina; Pereira, Martha Maria

    2012-12-01

    The presence of Leptospira spp. and Brucella spp. antibodies was investigated in serum samples from 28 collared anteaters (Tamandua tetradactyla) kept in seven Brazilian zoos. Sera were tested against 19 Leptospira serovars using microscopic agglutination. Samples reacted to the following serovars: two (7.14%) to Patoc, three (10.71%) to Tarrasovi, three (10.71%) to both Patoc and Tarrasovi, two (7.14%) to Wolffi, and one (3.57%) to Australis. Two (7.14%) samples reacted to the buffered Brucella antigen test, but no confirmatory reaction occurred using the 2-mercaptoethanol slow slide agglutination test. No sample was reactive in the agar gel immunodiffusion test for rugose species of Brucella. The presence of anti-leptospira agglutinins in captive T. tetradactyla serum indicates that this species may be susceptible to infection by these bacteria.

  16. A novel flow cytometry-based assay for the quantification of antibody-dependent pneumococcal agglutination

    PubMed Central

    van der Gaast—de Jongh, Christa E.; Diavatopoulos, Dimitri A.; de Jonge, Marien I.

    2017-01-01

    The respiratory pathogen Streptococcus pneumoniae is a major cause of diseases such as otitis media, pneumonia, sepsis and meningitis. The first step towards infection is colonization of the nasopharynx. Recently, it was shown that agglutinating antibodies play an important role in the prevention of mucosal colonization with S. pneumoniae. Here, we present a novel method to quantify antibody-dependent pneumococcal agglutination in a high-throughput manner using flow cytometry. We found that the concentration of agglutinating antibodies against pneumococcal capsule are directly correlated with changes in the size and complexity of bacterial aggregates, as measured by flow cytometry and confirmed by light microscopy. Using the increase in size, we determined the agglutination index. The cutoff value was set by measuring a series of non-agglutinating antibodies. With this method, we show that not only anti-polysaccharide capsule antibodies are able to induce agglutination but that also anti-PspA protein antibodies have agglutinating capabilities. In conclusion, we have described and validated a novel method to quantify pneumococcal agglutination, which can be used to screen sera from murine or human vaccination studies, in a high-throughput manner. PMID:28288168

  17. A critical review of published methods for analysis of red cell antigen-antibody reactions by flow cytometry, and approaches for resolving problems with red cell agglutination.

    PubMed

    Arndt, Patricia A; Garratty, George

    2010-07-01

    Flow cytometry operators often apply familiar white blood cell (WBC) methods when studying red blood cell (RBC) antigens and antibodies. Some WBC methods are not appropriate for RBCs, as the analysis of RBCs requires special considerations, for example, avoidance of agglutination. One hundred seventy-six published articles from 88 groups studying RBC interactions were reviewed. Three fourths of groups used at least one unnecessary WBC procedure for RBCs, and about one fourth did not use any method to prevent/disperse RBC agglutination. Flow cytometric studies were performed to determine the effect of RBC agglutination on results and compare different methods of preventing and/or dispersing agglutination. The presence of RBC agglutinates have been shown to be affected by the type of pipette tip used for mixing RBC suspensions, the number of antigen sites/RBC, the type and concentration of primary antibody, and the type of secondary antibody. For quantitation methods, for example, fetal maternal hemorrhage, the presence of agglutinates have been shown to adversely affect results (fewer fetal D+ RBCs detected). Copyright 2010 Elsevier Inc. All rights reserved.

  18. The value of automated gel column agglutination technology in the identification of true inherited D blood types in massively transfused patients.

    PubMed

    Summers, Thomas; Johnson, Viviana V; Stephan, John P; Johnson, Gloria J; Leonard, George

    2009-08-01

    Massive transfusion of D- trauma patients in the combat setting involves the use of D+ red blood cells (RBCs) or whole blood along with suboptimal pretransfusion test result documentation. This presents challenges to the transfusion service of tertiary care military hospitals who ultimately receive these casualties because initial D typing results may only reflect the transfused RBCs. After patients are stabilized, mixed-field reaction results on D typing indicate the patient's true inherited D phenotype. This case series illustrates the utility of automated gel column agglutination in detecting mixed-field reactions in these patients. The transfusion service test results, including the automated gel column agglutination D typing results, of four massively transfused D- patients transfused D+ RBCs is presented. To test the sensitivity of the automated gel column agglutination method in detecting mixed-field agglutination reactions, a comparative analysis of three automated technologies using predetermined mixtures of D+ and D- RBCs is also presented. The automated gel column agglutination method detected mixed-field agglutination in D typing in all four patients and in the three prepared control specimens. The automated microwell tube method identified one of the three prepared control specimens as indeterminate, which was subsequently manually confirmed as a mixed-field reaction. The automated solid-phase method was unable to detect any mixed fields. The automated gel column agglutination method provides a sensitive means for detecting mixed-field agglutination reactions in the determination of the true inherited D phenotype of combat casualties transfused massive amounts of D+ RBCs.

  19. Production of latex agglutination reagents for pneumococcal serotyping

    PubMed Central

    2013-01-01

    Background The current ‘gold standard’ for serotyping pneumococci is the Quellung test. This technique is laborious and requires a certain level of training to correctly perform. Commercial pneumococcal latex agglutination serotyping reagents are available, but these are expensive. In-house production of latex agglutination reagents can be a cost-effective alternative to using commercially available reagents. This paper describes a method for the production and quality control (QC) of latex reagents, including problem solving recommendations, for pneumococcal serotyping. Results Here we describe a method for the production of latex agglutination reagents based on the passive adsorption of antibodies to latex particles. Sixty-five latex agglutination reagents were made using the PneuCarriage Project (PCP) method, of which 35 passed QC. The other 30 reagents failed QC due to auto-agglutination (n=2), no reactivity with target serotypes (n=8) or cross-reactivity with non-target serotypes (n=20). Dilution of antisera resulted in a further 27 reagents passing QC. The remaining three reagents passed QC when prepared without centrifugation and wash steps. Protein estimates indicated that latex reagents that failed QC when prepared using the PCP method passed when made with antiserum containing ≤ 500 μg/ml of protein. Sixty-one nasopharyngeal isolates were serotyped with our in-house latex agglutination reagents, with the results showing complete concordance with the Quellung reaction. Conclusions The method described here to produce latex agglutination reagents allows simple and efficient serotyping of pneumococci and may be applicable to latex agglutination reagents for typing or identification of other microorganisms. We recommend diluting antisera or removing centrifugation and wash steps for any latex reagents that fail QC. Our latex reagents are cost-effective, technically undemanding to prepare and remain stable for long periods of time, making them ideal for use in low-income countries. PMID:23379961

  20. Systems, devices, and methods for agglutination assays using sedimentation

    DOEpatents

    Schaff, Ulrich Y.; Sommer, Gregory J.; Singh, Anup K.

    2016-01-26

    Embodiments of the present invention include methods for conducting agglutination assays using sedimentation. Aggregates may be exposed to sedimentation forces and travel through a density medium to a detection area. Microfluidic devices, such as microfluidic disks, are described for conducting the agglutination assays, as are systems for conducting the assays.

  1. [Microbiology--laboratory examinations for bacterias].

    PubMed

    Hen, Renjun; Imafuku, Yuji; Yoshida, Hiroshi

    2002-11-01

    As it has been required to identify pathogenic microbes in shorter times, simple and rapid methods have been developed and used. Here, we summarized the present situation of rapid diagnostic testing in clinical microbiology in Japan, and also presented our results on PBP2' detection. The rapid test kits available in Japan for E. coli, Helicobacter pylori, Salmonella, Streptococcus and Staphylococcus aureus were described. Rapid examination methods are based mainly on immunologic reactions, which included slide agglutination using latex particle, immunochromatography and ELISA. Times required for the identification are 10 to 15 minutes. Moreover, rapid test kits employing PCR are also marketed. Further, we evaluated MRSA-LA "Seiken" which is a rapid detection kit for PBP2' produced by MRSA. The test was shown to be highly sensitive and specific. For the rapid identification of pathogenic microbes, simple and rapid test kits described here will be used more in clinical diagnosis.

  2. Rapid presumptive identification of Cryptococcus neoformans by staphylococcal coagglutination.

    PubMed Central

    Maccani, J E

    1981-01-01

    A coagglutination reagent was prepared by sensitizing the Cowan I strain of Staphylococcus aureus with rabbit immune globulin directed against Cryptococcus neofromans A15 and absorbed with C. laurentii. This reagent was evaluated for its usefulness in differentiating C. neoformans from other yeast colonies rapidly. Antigen-containing extracts were prepared form Sabouraud dextrose agar cultures of 48 C. neoformans, 33 other Cryptococcus species, 21 Candida, 4 Torulopsis, 3 Saccharomyces, and 2 Rhodotorula strains. This was done by suspending a 0.001-ml loopful of colony growth in 0.5 ml of phenolized saline, mixing for 30 s, and then centrifuging. Equal volumes (50 microliters) of coagglutination reagent and yeast extract were mixed within marked circles on a glass slide and then mechanically rotated at 180 rpm for 8 min. Forty-five of the 48 strains of C. neoformans produced strong (3+ to 4+) agglutination, and 3 strains of serotype C produced weak (1+ to 2+) agglutination with the reagent. Other Cryptococcus species which reacted positively were 4 C. albidus subsp. diffluens, 7 C. albidus subsp. albidus, and 2 C. terreus strains; however, false-positive errors in identification were circumvented by performing a supplemental rapid test for nitrate utilization which differentiated these yeasts from C. neoformans. None of the other yeasts tested (including 14 C. laurentii, 2 C. luteolus, and 2 C. uniguttulatus strains) produced any degree of agglutination with the reagent. A commercial cryptococcal latex agglutination reagent (Crypto-Test, Microbiological Associates, Walkersville, Md.) proved less reliable for identifying C. neoformans yeast colonies because of cross-reactions which occurred with all other species of Cryptococcus tested. PMID:7016909

  3. Enteric Bacterial Pathogens in Children with Diarrhea in Niger: Diversity and Antimicrobial Resistance

    PubMed Central

    Moumouni, Aissatou; Gouali, Malika; Mamaty, Abdoul-Aziz; Grais, Rebecca F.

    2015-01-01

    Background Although rotavirus is the leading cause of severe diarrhea among children in sub-Saharan Africa, better knowledge of circulating enteric pathogenic bacteria and their antimicrobial resistance is crucial for prevention and treatment strategies. Methodology/Principal Findings As a part of rotavirus gastroenteritis surveillance in Maradi, Niger, we performed stool culture on a sub-population of children under 5 with moderate-to-severe diarrhea between April 2010 and March 2012. Campylobacter, Shigella and Salmonella were sought with conventional culture and biochemical methods. Shigella and Salmonella were serotyped by slide agglutination. Enteropathogenic Escherichia coli (EPEC) were screened by slide agglutination with EPEC O-typing antisera and confirmed by detection of virulence genes. Antimicrobial susceptibility was determined by disk diffusion. We enrolled 4020 children, including 230 with bloody diarrhea. At least one pathogenic bacterium was found in 28.0% of children with watery diarrhea and 42.2% with bloody diarrhea. Mixed infections were found in 10.3% of children. EPEC, Salmonella and Campylobacter spp. were similarly frequent in children with watery diarrhea (11.1%, 9.2% and 11.4% respectively) and Shigella spp. were the most frequent among children with bloody diarrhea (22.1%). The most frequent Shigella serogroup was S. flexneri (69/122, 56.5%). The most frequent Salmonella serotypes were Typhimurimum (71/355, 20.0%), Enteritidis (56/355, 15.8%) and Corvallis (46/355, 13.0%). The majority of putative EPEC isolates was confirmed to be EPEC (90/111, 81.1%). More than half of all Enterobacteriaceae were resistant to amoxicillin and co-trimoxazole. Around 13% (46/360) Salmonella exhibited an extended-spectrum beta-lactamase phenotype. Conclusions This study provides updated information on enteric bacteria diversity and antibiotic resistance in the Sahel region, where such data are scarce. Whether they are or not the causative agent of diarrhea, bacterial infections and their antibiotic resistance profiles should be closely monitored in countries like Niger where childhood malnutrition pre-disposes to severe and invasive infections. PMID:25799400

  4. Ultraviolet and visible light spectrophotometric approach to blood typing: objective analysis by agglutination index.

    PubMed

    Narayanan, S; Orton, S; Leparc, G F; Garcia-Rubio, L H; Potter, R L

    1999-10-01

    A new blood typing technology based on ultraviolet (UV) and visible light spectroscopy (UV/visible spectroscopy) has been developed. Blood groups and types are determined by quantifying reproducible changes in the UV and visible light spectra of blood in the presence of agglutinating antibodies. Samples of red cells in the presence and absence of agglutinating antibodies were examined by UV/visible spectroscopy. Blood groups and types were determined by comparing the optical density spectra obtained between 665 and 1000 nm. These comparisons generate numbers (agglutination index) ranging from 0 to 100, with smaller numbers corresponding to lack of agglutination and larger numbers corresponding to agglutination. The optical density of agglutinated blood is dramatically different from that of unagglutinated blood. The agglutination index derived from the relative slopes of the spectra is an objective indicator of agglutination strength. An agglutination index greater than 17 consistently and accurately established blood group- and type-specific agglutination. The method accurately predicted A, B, and O blood groups, and D type in over 275 samples. Scattering theory-based calculations of relative volumes of red cells before and after agglutination show a direct correlation with the agglutination index and provide the theoretical basis of the analysis. This quantitative technique is reproducible and has the potential for automation.

  5. Application of a spectrally filtered probing light beam and RGB decomposition of microphotographs for flow registration of ultrasonically enhanced agglutination of erythrocytes

    NASA Astrophysics Data System (ADS)

    Doubrovski, V. A.; Ganilova, Yu. A.; Zabenkov, I. V.

    2013-08-01

    We propose a development of the flow microscopy method to increase the resolving power upon registration of erythrocyte agglutination. We experimentally show that the action of a ultrasonic standing wave on an agglutinating mixture blood-serum leads to the formation of so large erythrocytic immune complexes that it seems possible to propose a new two-wave optical method of registration of the process of erythrocyte agglutination using the RGB decomposition of microphotographs of the flow of the mixture under study. This approach increases the reliability of registration of erythrocyte agglutination and, consequently, increases the reliability of blood typing. Our results can be used in the development of instruments for automatic human blood typing.

  6. Conventional Rapid Latex Agglutination in Estimation of von Willebrand Factor: Method Revisited and Potential Clinical Applications

    PubMed Central

    Che Hussin, Che Maraina

    2014-01-01

    Measurement of von Willebrand factor antigen (VWF : Ag) levels is usually performed in a specialised laboratory which limits its application in routine clinical practice. So far, no commercial rapid test kit is available for VWF : Ag estimation. This paper discusses the technical aspect of latex agglutination method which was established to suit the purpose of estimating von Willebrand factor (VWF) levels in the plasma sample. The latex agglutination test can be performed qualitatively and semiquantitatively. Reproducibility, stability, linearity, limit of detection, interference, and method comparison studies were conducted to evaluate the performance of this test. Semiquantitative latex agglutination test was strongly correlated with the reference immunoturbidimetric assay (Spearman's rho = 0.946, P < 0.001, n = 132). A substantial agreement (κ = 0.77) was found between qualitative latex agglutination test and the reference assay. Using the scoring system for the rapid latex test, no agglutination is with 0% VWF : Ag (control negative), 1+ reaction is equivalent to <20% VWF : Ag, and 4+ reaction indicates >150% VWF : Ag (when comparing with immunoturbidimetric assay). The findings from evaluation studies suggest that latex agglutination method is suitable to be used as a rapid test kit for the estimation of VWF : Ag levels in various clinical conditions associated with high levels and low levels of VWF : Ag. PMID:25759835

  7. [An evaluation of the effectiveness of laboratory diagnostic methods for brucellosis].

    PubMed

    Gandara, B; Zheludkov, M M; Chernysheva, M I

    1994-01-01

    The diagnostic value of bacteriological and serological methods for the laboratory diagnosis of brucellosis was studied. In the analysis of milk and cheese specimens Brucella cultures were isolated and differentiated as B.melitensis, biovar I, and B.abortus, biovar 4. In 25.6% of cases B.melitensis culture, biovar 1, was isolated from the blood of persons suspected for brucellosis. The isolation of B.melitensis culture from milk showed that this infective agent migrated from small animals to cattle, which was indicative of a high risk of human infection in the state of Zacatecas, Mexico. The comparative evaluation of serological diagnostic methods (the agglutination test in test tubes, Huddleson's slide test, the acidic rose bengal test and the 2-mercaptoethanol test) showed high sensitivity of rapid tests (Huddleson's test and the rose bengal test in 93.7% and 87.9% of cases respectively). The 2-mercaptoethanol test which gave positive results in 63.8% of cases provided additional information characterizing the course of infections process.

  8. Simple Tests for Rapid Detection of Canine Parvovirus Antigen and Canine Parvovirus-Specific Antibodies▿ †

    PubMed Central

    Marulappa, Shashidhara Y.; Kapil, Sanjay

    2009-01-01

    Canine parvovirus (CPV) is the number one viral cause of enteritis, morbidity, and mortality in 8-week-old young puppies. We have developed twin assays (slide agglutination test [SAT] for CPV antigen and slide inhibition test [SIT] for CPV antibody) that are sensitive, specific, cost-effective, generic for all genotypes of CPV, and provide instant results for CPV antigen detection in feces and antibody quantification in serum. We found these assays to be useful for routine applications in kennels with large numbers of puppies at risk. The results of these assays are available in 1 min and do not require any special instrumentation. SAT-SIT technology will find applications in rapid screening of samples for other hemagglutinating emerging viruses of animals and humans (influenza virus and severe acute respiratory syndrome coronavirus). PMID:18987166

  9. Diagnosis and Treatment of Typhoid Fever and Associated Prevailing Drug Resistance in Northern Ethiopia.

    PubMed

    Wasihun, Araya Gebreyesus; Wlekidan, Letemichael Negash; Gebremariam, Senay Aregawi; Welderufael, Abadi Luel; Muthupandian, Saravanan; Haile, Tadesse Dejenie; Dejene, Tsehaye Asmelash

    2015-06-01

    To determine diagnostic value of the Widal test, treatment pattern of febrile patients and antimicrobial drug susceptibility pattern of blood isolates. Using cross sectional methods, blood samples were collected for culture and Widal test from 502 febrile outpatients attending Mekelle hospital and Mekelle health center with similar symptoms to typhoid. Sensitivity, specificity for anti-TH and anti-TO titers using culture confirmed typhoid fever cases, and Kappa agreement between Titer and slide Widal tests were calculated. Treatment pattern of patients and antimicrobial susceptibility pattern of the blood isolates was assessed. From the 502 febrile patients, 8(1.6%) of them had culture-proven typhoid fever. However, patients who have results indicative of recent infection by O and H antigens of the Widal slide agglutination test were 343 (68.5%), with specificity and sensitivity of 33% and 100%, respectively. Over prescription of antibiotics was seen by Widal slide test for Ciprofloxacin 268 (76.1%), Amoxicillin- Clavulanic acid 9(2.6%), Amoxicillin 8(2.4%) and Chloranphenicol 8(2.4%). Tube titer positivity was seen in 23(5.3%) patients with 75% sensitivity and 95.8% specificity. Widal slide and Tube titer tests showed poor agreement for both antigens (kappa=0.02 for O) and (Kappa=0.09 for H). A single anti-TH titer of ≥ 1:160 and anti-TO titer ≥ 1:80 higher in our study showed an indication for typhoid fever infection. Drug resistance pattern of blood isolates ranges from 0-89.7% for gram positive and 0-100% for Gram negative, with an overall multi-drug resistance rate of 61.7%. Patients were wrongly diagnosed and treated for typhoid fever by Widal test. The tube titration method was relatively good but still had poor sensitivity. Blood isolates showed multi drug resistance, which may be due to the indiscriminate prescription as seen in this study. Based on our results, the slide Widal test is not helpful in the diagnosis of typhoid, hence other tests with rapid, feasible, better sensitivity and specificity are urgently needed in Ethiopia. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. STUDIES ON THE ANTIGENIC STRUCTURE OF SOME MAMMALIAN SPERMATOZOA

    PubMed Central

    Henle, Werner; Henle, Gertrude; Chambers, Leslie A.

    1938-01-01

    1. A method has been described for separation of heads and tails of mammalian spermatozoa. 2. By means of absorption technique applied to homologous spermatozoal sera, head-specific and tail-specific antigens could be demonstrated. Both are heat-labile. 3. A heat-stable antigen was found to be common to both heads and tails. This substance is species-specific. 4. Antibodies against the head- and tail-specific antigens led to two different types of agglutination as shown by the slide method. 5. Using heterologous antisera against spermatozoa three different cross-reacting antigens could be observed, two in the heads, one in the tails. 6. One of the head-antigens is not active in the native cell; it comes to action only after breaking the cell. Antibodies against this substance were not found in antisera against native bull spermatozoa but were formed when vibrated spermatozoa or heads were injected into rabbits. 7. The cross-reactions can be removed from an antiserum leaving the head- as well as the tail-specific reaction intact. PMID:19870792

  11. Determination of degree of RBC agglutination for blood typing using a small quantity of blood sample in a microfluidic system.

    PubMed

    Chang, Yaw-Jen; Ho, Ching-Yuan; Zhou, Xin-Miao; Yen, Hsiu-Rong

    2018-04-15

    Blood typing assay is a critical test to ensure the serological compatibility of a donor and an intended recipient prior to a blood transfusion. This paper presents a microfluidic blood typing system using a small quantity of blood sample to determine the degree of agglutination of red blood cell (RBC). Two measuring methods were proposed: impedimetric measurement and electroanalytical measurement. The charge transfer resistance in the impedimetric measurement and the power parameter in the electroanalytical measurement were used for the analysis of agglutination level. From the experimental results, both measuring methods provide quantitative results, and the parameters are linearly and monotonically related to the degree of RBC agglutination. However, the electroanalytical measurement is more reliable than the impedimetric technique because the impedimetric measurement may suffer from many influencing factors, such as chip conditions. Five levels from non-agglutination (level 0) to strong agglutination (level 4+) can be discriminated in this study, conforming to the clinical requirement to prevent any risks in transfusion. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Tube and column agglutination technology for autocontrol testing.

    PubMed

    Courtney, J E; Vincent, J L; Indrikovs, A J

    2001-01-01

    The incidence of positive autocontrol test results with column agglutination technology is a concern. This study investigates the incidence and significance of positive autocontrols in the ID Micro Typing System (gel) and the Gamma ReACT (ReACT). The study encompassed a total of 1021 randomly selected samples from patients and 95 samples from donors collected during 1 month. The autocontrol testing was carried out according to the manufacturer's instructions for the column agglutination tests. The tube method was carried out using low-ionic-strength solution (LISS). The direct antiglobulin test (DAT) was performed using the tube method, and further investigated with elution studies if warranted. Seventy-nine patient's samples (7.74%) had a positive autocontrol: the gel test, 72 (91.13%); ReACT, 21 (26.58%); and the tube method, 27 (34.18%). Of the 79 positive autocontrols, 44 samples had a negative DAT. Of the samples with positive DAT results, only one possessed a clinically significant antibody, anti-D. Moreover, the same sample also tested positive in all three methods. Column agglutination techniques have increased sensitivity for a positive autocontrol beyond the conventional tube method. However, ReACT and gel tests differ significantly in their frequency of positives. Investigation of the significance of a positive autocontrol in column agglutination technology when the conventional tube method is also positive is suggested.

  13. Light-scattering analysis of ultrasonic wave's influence on the RBC agglutination in vitro

    NASA Astrophysics Data System (ADS)

    Doubrovski, Valeri A.; Dvoretski, Costanten N.

    1999-04-01

    Elastic light scattering is one of the most often used optical methods to analyze the cells agglutination reaction - the base of a great number of medical diagnostic test and biomedical investigations. The increase of the resolution of methods and apparatus towards the induced cells aggregation - the foundation of the reaction of agglutination, is quite an actual problem. The solution of this problem increases the reliability of the diagnostic test and gives an opportunity to achieve the diagnostic information in the cases when the traditional approaches do not lead to the diagnostic results. The attempt to increase the resolution of the immune reaction analyzer by means of ultrasonic waves action on the reagent mixture in vitro is taken in this paper. The RBC agglutination reaction which is usually used for the blood group type examination is chosen as an example of an object of the investigation. Different laser optical trains of the devices based on the turbidimetric and nephelometric methods and their combination are analyzed here. The influence of the ultrasonic wave time interval action and of the features of the sample preparation procedure on the resolution towards the agglutination process was investigated in this work. It is shown that the ultrasonic wave action on the reagent mixture leads to a large gain in the resolution of the device towards the RBC agglutination process. The experiments showed that the resolution of the device was enough to register the agglutination process even for the erythrocytes with weak agglutination ability when the reaction was invisible without ultrasonic action. It occurred that the diagnostic test time was more than by an order shortened due to the ultrasonic wave action. The optimal ultrasonic time interval action, the sample preparation technology and experimental technique were defined. The principle of the ultrasonic wave action on the cells agglutination process suggested here can be spread out on the immune molecular media. The results may be useful to develop new apparatus and methods for the aims of medical laboratory diagnostics.

  14. Evaluation of new indigenous "point-of-care" ABO and Rh grouping device.

    PubMed

    Tiwari, Aseem Kumar; Setya, Divya; Aggarwal, Geet; Arora, Dinesh; Dara, Ravi C; Ratan, Ankita; Bhardwaj, Gunjan; Acharya, Devi Prasad

    2018-01-01

    Erycard 2.0 is a "point-of-care" device that is primarily being used for patient blood grouping before transfusion. Erycard 2.0 was compared with conventional slide technology for accuracy and time taken for ABO and Rh forward grouping result with column agglutination technology (CAT) being the gold standard. Erycard 2.0 as a device was also evaluated for its stability under different storage conditions and stability of result till 48 h. In addition, grouping of hemolyzed samples was also tested with Erycard 2.0. Ease of use of Erycard 2.0 was evaluated with a survey among paramedical staff. Erycard 2.0 demonstrated 100% concordance with CAT as compared with slide technique (98.9%). Mean time taken per test by Erycard 2.0 and slide technique was 5.13 min and 1.7 min, respectively. After pretesting storage under different temperature and humidity conditions, Erycard 2.0 did not show any deviation from the result. The result did not change even after 48 h of testing and storage under room temperature. 100% concordance was recorded between pre- and post-hemolyzed blood grouping. Ease of use survey revealed that Erycard 2.0 was more acceptable to paramedical staff for its simplicity, objectivity, and performance than conventional slide technique. Erycard 2.0 can be used as "point-of-care" device for blood donor screening for ABO and Rh blood group and can possibly replace conventional slide technique.

  15. Weak "A" blood subgroup discrimination by a rheo-optical method: a new application of laser backscattering

    NASA Astrophysics Data System (ADS)

    Rasia, Rodolfo J.; Rasia-Valverde, Juana R.; Stoltz, Jean F.

    1996-01-01

    Laser backscattering is an excellent tool to investigate size and concentration of suspended particles. It was successfully applied to the analysis of erythrocyte aggregation. A method is proposed that applies laser backscattering to the evaluation of the strength of the immunologic erythrocyte agglutination by approaching the energy required for the mechanical dissociation of agglutinates. Mills and Snabre have proposed a theory of laser backscattering for erythrocyte aggregation analysis. It is applied here to analyze the dissociation process of erythrocyte agglutinates performed by imposing a constant shear rate to the agglutinate suspension in a couette viscometer until a dispersion of isolated red cells is attained. Experimental verifications of the method were performed on the erythrocytes of the ABO group reacting against an anti-A test serum in twofold series dilutions. Spent energy is approached by a numerical process carried out on the backscattered intensity data registered during mechanical dissociation. Velocities of agglutination and dissociation lead to the calculation of dissociation parameters These values are used to evaluate the strength of the immunological reaction and to discriminate weak subgroups of ABO system.

  16. Serological study of brucellosis in Argentine Creole sheep.

    PubMed

    López, Gustavo E; Peña, Sabrina; Escobar, Gabriela I; Hasan, Déborah B; Lucero, Nidia E

    2018-01-05

    Ovine cattle was introduced into America during the Spanish conquest with the second journey of Columbus to the Antilles and was disseminated throughout the region. In 1587, sheep were introduced into Argentina, later developing into the "Creole" breed. We selected 486 animals from different Argentine provinces with the aim of determining the serological status of brucellosis caused by Brucella melitensis and Brucella ovis. For the detection of antibodies against smooth Brucella spp., the Rose Bengal test (RBT) was performed as screening test while the serum agglutination test (SAT) and 2 mercapto-ethanol (2ME) were run as a confirmatory technique. Moreover, for the detection of antibodies against rough Brucella spp., we used the rapid slide agglutination test (RSAT) for screening and an indirect ELISA (IELISA) as confirmatory assay. This study showed that the total positive percentage of brucellosis due to B. ovis was 2.9%. Excluding the animals mixed with the Suffolk breed; seropositivity would be 0.6%. All animals tested negative for brucellosis caused by B. melitensis. Copyright © 2017 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Comparison of Various Methods in the Diagnosis of Entamoeba histolytica in Stool and Serum Specimens

    PubMed Central

    Uslu, Hakan; Aktas, Osman; Uyanik, Muhammet Hamidullah

    2016-01-01

    Objective: Entamoeba histolytica is indistinguishable from Entamoeba dispar in direct microscopic examination. A definitive diagnosis of E. histolytica is important in terms of the treatment of the patient and to avoid unnecessary costs. This study’s aim is to determine the prevalence of E. histolytica and to make a comparison of the different diagnostic tests in the patients specimens defined as E. histolytica/E. dispar infection. Materials and Methods: Faecal and serum specimens of 90 patients defined as E. histolytica/E. dispar with microscopy (wet mount examination with 0.85% saline and Lugol’s iodine) were examined. Stool samples were examined by trichrome staining for trophozoites and cysts and by immunoassay methods for specific adhesin antigens (Wampole ® E. histolytica II antigen testing) and for specific serine-rich 30 kD membrane protein (Serazym® E. histolytica antigen testing). Anti-E. histolytica antibodies were investigated using a latex slide test and indirect hemagglutination methods in serum specimens. Results: Presence of E. histolytica was not confirmed in 31.1% cases with trichrome staining, 62.2% of the Wampole antigen test, 64.4%, of the Serazym antigen test, 73.3% of the indirect hemagglutination test and 75.6%. of the latex agglutination. Considering the common results from Wampole and Serazym antigen testing as a reference standard, the specificity/sensitivity is 100/53.85% for trichrome staining, 75.00/98.11% for the latex agglutination test and 78.57/96.77% for the indirect hemagglutination test. Conclusion: It has been shown that investigation of E. histolytica in stools by direct wet-smear microscopy alone can cause significant false positive results. To obtain a reliable diagnosis for E. histolytica and to avoid unnecessary treatment for this parasite, at least one more specific assay, particularly an antigen testing and microscopy, is required. PMID:27551176

  18. Agglutination of Helicobacter pylori coccoids by lectins

    PubMed Central

    Khin, Mar Mar; Hua, Jie Song; Ng, Han Cong; Wadström, Torkel; Ho, Bow

    2000-01-01

    AIM: To study the agglutination pattern of Helicobacter pylori coccoid and spiral forms. METHODS: Assays of agglutination and agglutination inhibition were applied using fifteen commercial lectins. RESULTS: Strong agglutination was observed with mannose-specific Concanavalin A (Con A), fucose-specific Tetragonolobus purpureas (Lotus A) and N-acetyl glucosamine-specific Triticum vulgaris (WGA) lectins. Mannose and fucose specific lectins were reactive with all strains of H. pylori coccoids as compared to the spirals. Specific carbohydrates, glycoproteins and mucin were shown to inhibit H. pylori lectin-agglutination reactions. Pre-treatment of the bacterial cells with formalin and sulphuric acid did not alter the agglutination patterns with lectins. However, sodium periodate treatment of bacterial cells were shown to inhibit agglutination reaction with Con A, Lotus A and WGA lectins. On the contrary, enzymatic treatment of coccoids and spirals did not show marked inhibition of H. pylori lectin agglutination. Interes tingly, heating of H. pylori cells at 60 °C for 1 h was shown to augment the agglutination with all of the lectins tested. CONCLUSION: The considerable differences in lectin agglutination patterns seen among the two differentiated forms of H. pylori might be attributable to the structural changes during the events of morphological transformation, resulting in exposing or masking some of the sugar residues on the cell surface. Possibility of various sugar residues on the cell wall of the coccoids may allow them to bind to different carbohydrate receptors on gastric mucus and epithelial cells. The coccoids with adherence characteristics like the spirals could aid in the pathogenic process of Helicobacter infection. This may probably lead to different clinical outcome of H. pylori associated gastroduodenal disease. PMID:11819557

  19. An integrated fiberoptic-microfluidic device for agglutination detection and blood typing.

    PubMed

    Ramasubramanian, Melur K; Alexander, Stewart P

    2009-02-01

    In this paper, an integrated fiberoptic-microfluidic device for the detection of agglutination for blood type cross-matching has been described. The device consists of a straight microfluidic channel through with a reacted RBC suspension is pumped with the help of a syringe pump. The flow intersects an optical path created by an emitter-received fiber optic pair integrated into the microfluidic device. A 650 nm laser diode is used as the light source and a silicon photodiode is used to detect the light intensity. The spacing between the tips of the two optic fibers can be adjusted. When fiber spacing is large and the concentration of the suspension is high, scattering phenomenon becomes the dominant mechanism for agglutination detection while at low concentrations and small spacing, optointerruption becomes the dominant mechanism. An agglutination strength factor (ASF) is calculated from the data. Studies with a variety of blood types indicate that the sensing method correctly identifies the agglutination reaction in all cases. A disposable integrated device can be designed for future implementation of the method for near-bedside pre-transfusion check.

  20. Simplified spectraphotometric method for the detection of red blood cell agglutination.

    PubMed

    Ramasubramanian, Melur; Anthony, Steven; Lambert, Jeremy

    2008-08-01

    Human error is the most significant factor attributed to incompatible blood transfusions. A spectrophotometric approach to blood typing has been developed by examining the spectral slopes of dilute red blood cell (RBC) suspensions in saline, in the presence and absence of various antibodies, offering a technique for the quantitative determination of agglutination intensity [Transfusion39, 1051, 1999TRANAT0041-113210.1046/j.1537-2995.1999.39101051.x]. We offer direct theoretical prediction of the observed change in slope in the 660-1000 nm range through the use of the T-matrix approach and Lorenz-Mie theory for light scattering by dilute RBC suspensions. Following a numerical simulation using the T-matrix code, we present a simplified sensing method for detecting agglutination. The sensor design has been prototyped, fully characterized, and evaluated through a complete set of tests with over 60 RBC samples and compared with the full spectrophotometric method. The LED and photodiode pairs are found to successfully reproduce the spectroscopic determination of red blood cell agglutination.

  1. Comparison of four methods for rapid identification of Staphylococcus aureus directly from BACTEC 9240 blood culture system.

    PubMed

    Ozen, N S; Ogunc, D; Mutlu, D; Ongut, G; Baysan, B O; Gunseren, F

    2011-01-01

    Differentiation of Staphylococcus aureus (S. aureus) from coagulase-negative staphylococci is very important in blood stream infections. Identification of S. aureus and coagulase-negative staphylococci (CoNS) from blood cultures takes generally 18-24 h after positive signaling on continuously monitored automated blood culture system. In this study, we evaluated the performance of tube coagulase test (TCT), slide agglutination test (Dry Spot Staphytect Plus), conventional polymerase chain reaction (PCR) and LightCycler Staphylococcus MGrade kit directly from blood culture bottles to achieve rapid identification of S. aureus by using the BACTEC 9240 blood culture system. A total of 129 BACTEC 9240 bottles growing gram-positive cocci suggesting Staphylococci were tested directly from blood culture broths (BCBs) with TCT, Dry Spot Staphytect Plus, conventional PCR and LightCycler Staphylococcus MGrade kit for rapid identification of S. aureus. The sensitivities of the tests were 99, 68, 99 and 100%, respectively. Our results suggested that 2 h TCT was found to be simple and inexpensive method for the rapid identification of S. aureus directly from positive blood cultures.

  2. Comparison of a New and Rapid Method: Brucella Coombs Gel Test With Other Diagnostic Tests.

    PubMed

    Kalem, Fatma; Ergün, Ayşe Gül; Durmaz, Süleyman; Doğan, Metin; Ertuğrul, Ömür; Gündem, Seval

    2016-09-01

    The aim of this study was to detect reliability of Brucella Coombs gel test (BCGT) by comparing with with ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination methods in serological diagnosis of brucellosis. Brucella Coombs gel test (BCGT), Brucella ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination tests of 78 patients with presumptive diagnosis of brucellosis which were sent to Microbiology Laboratory of Konya Numune Hospital from various regions of Konya were studied. Of 78 patients with ELISA IgG and IgM, STA, BICA and BCGT; 26, 21, 10, 12 and 12 were positive. When compared with BICA, the sensitivity and specifity of BCGT were 100% and 100%, respectively. According to results BCGT can be used as a diagnostic test in routine laboratories after more comprehensive studies in control groups and patients. © 2016 Wiley Periodicals, Inc.

  3. Measuring electrical and mechanical properties of red blood cells with a double optical tweezers

    NASA Astrophysics Data System (ADS)

    Fontes, Adriana; Fernandes, Heloise P.; Barjas-Castro, Maria L.; de Thomaz, André A.; Pozzo, Liliana d. Y.; Barbosa, Luiz C.; Cesar, Carlos L.

    2006-08-01

    The fluid lipid bilayer viscoelastic membrane of red blood cells (RBC) contains antigen glycolproteins and proteins which can interact with antibodies to cause cell agglutination. This is the basis of most of the immunohematologic tests in blood banks and the identification of the antibodies against the erythrocyte antigens is of fundamental importance for transfusional routines. The negative charges of the RBCs creates a repulsive electric (zeta) potential between the cells and prevents their aggregation in the blood stream. The first counterions cloud strongly binded moving together with the RBC is called the compact layer. This report proposes the use of a double optical tweezers for a new procedure for measuring: (1) the apparent membrane viscosity, (2) the cell adhesion, (3) the zeta potential and (4) the compact layer's size of the charges formed around the cell in the electrolytic solution. To measure the membrane viscosity we trapped silica beads strongly attached to agglutinated RBCs and measured the force to slide one RBC over the other as a function of the relative velocity. The RBC adhesion was measured by slowly displacing two RBCs apart until the disagglutination happens. The compact layer's size was measured using the force on the silica bead attached to a single RBC in response to an applied voltage and the zeta potential was obtained by measuring the terminal velocity after releasing the RBC from the optical trap at the last applied voltage. We believe that the methodology here proposed can improve the methods of diagnosis in blood banks.

  4. Typhoid fever in a Tertiary Hospital in Nigeria: Another look at the Widal agglutination test as a preferred option for diagnosis

    PubMed Central

    Enabulele, Osahon; Awunor, Simeon Nyemike

    2016-01-01

    Background: Single Widal agglutination test rather than blood culture, is commonly employed to diagnose typhoid fever in Nigeria. We took another look at the Widal agglutination test as a preferred option for diagnosis of typhoid fever by determining the specificity and sensitivity of Widal agglutination test in febrile adult patients. Materials and Methods: Two hundred and seventy-one blood samples from consecutive adults (>18 years) with febrile illness attending the General Practice Clinic of the University of Benin Teaching Hospital were tested using the Widal agglutination test, blood culture, and malaria parasite test on each sample to establish the diagnosis of typhoid fever. Results: Of the 271 blood samples 124 (45.76%) were positive following a Widal agglutination test, 60 (22.10%) blood samples grew Salmonella organisms on blood culture while 55 (20.29%) blood samples showed a co-infection of typhoid fever and malaria. A sensitivity of 35%, specificity of 51%, positive predictive value of 17%, and a negative predictive value of 73% were observed for Widal agglutination test as a diagnostic modality for typhoid fever infection. Conclusion: A single Widal agglutination test is not a valid diagnostic option for typhoid fever while co-infection with malaria parasite is the preponderant microbiological finding in typhoid fever infections. The severity of malaria parasitemia is associated with positive titers on Widal test. PMID:27397952

  5. The Staphylococcus aureus ArlRS Two-Component System Is a Novel Regulator of Agglutination and Pathogenesis

    PubMed Central

    Walker, Jennifer N.; Crosby, Heidi A.; Spaulding, Adam R.; Salgado-Pabón, Wilmara; Malone, Cheryl L.; Rosenthal, Carolyn B.; Schlievert, Patrick M.; Boyd, Jeffrey M.; Horswill, Alexander R.

    2013-01-01

    Staphylococcus aureus is a prominent bacterial pathogen that is known to agglutinate in the presence of human plasma to form stable clumps. There is increasing evidence that agglutination aids S. aureus pathogenesis, but the mechanisms of this process remain to be fully elucidated. To better define this process, we developed both tube based and flow cytometry methods to monitor clumping in the presence of extracellular matrix proteins. We discovered that the ArlRS two-component system regulates the agglutination mechanism during exposure to human plasma or fibrinogen. Using divergent S. aureus strains, we demonstrated that arlRS mutants are unable to agglutinate, and this phenotype can be complemented. We found that the ebh gene, encoding the Giant Staphylococcal Surface Protein (GSSP), was up-regulated in an arlRS mutant. By introducing an ebh complete deletion into an arlRS mutant, agglutination was restored. To assess whether GSSP is the primary effector, a constitutive promoter was inserted upstream of the ebh gene on the chromosome in a wildtype strain, which prevented clump formation and demonstrated that GSSP has a negative impact on the agglutination mechanism. Due to the parallels of agglutination with infective endocarditis development, we assessed the phenotype of an arlRS mutant in a rabbit combined model of sepsis and endocarditis. In this model the arlRS mutant displayed a large defect in vegetation formation and pathogenesis, and this phenotype was partially restored by removing GSSP. Altogether, we have discovered that the ArlRS system controls a novel mechanism through which S. aureus regulates agglutination and pathogenesis. PMID:24367264

  6. Antibodies to Coprococcus comes in sera of patients with Crohn's disease. Isolation and purification of the agglutinating antigen tested with an ELISA technique.

    PubMed

    Hazenberg, M P; van de Merwe, J P; Peña, A S; Pennock-Schröder, A M; van Lieshout, L M

    1987-07-01

    Previous studies showed that agglutinating antibodies to Coprococcus comes, an anaerobic Gram-positive coccoid rod isolated from the faecal flora of patients with Crohn's disease, are more frequently found in sera of Crohn patients than in ulcerative colitis patients and healthy subjects. Isolation of the antigen may be useful in developing a more sensitive and specific diagnostic test. The present study describes first a method to improve the presentation of the relevant agglutinating antigen by the bacterium and second, the purification by column chromatography of a relatively crude antigen extract of C. comes described previously by Hazenberg et al. (1). Comparative results with the agglutination reactions and ELISA technique of extensive series of patients with Crohn's disease and healthy subjects have shown that the agglutinating antigen of C. comes has been isolated. Although the present ELISA technique cannot replace the simple and reliable agglutination reaction for screening purposes, the purified antigen will allow further immunological studies and it is to be hoped that a deeper insight into pathogenesis of the disease will be gained.

  7. Studying red blood cell agglutination by measuring electrical and mechanical properties with a double optical tweezers

    NASA Astrophysics Data System (ADS)

    Fontes, Adriana; Fernandes, Heloise P.; de Thomaz, André A.; Barbosa, Luiz C.; Barjas-Castro, Maria L.; Cesar, Carlos L.

    2007-07-01

    The red blood cell (RBC) viscoelastic membrane contains proteins and glycolproteins embedded in, or attached, to a fluid lipid bilayer and are negatively charged, which creates a repulsive electric (zeta) potential between the cells and prevents their aggregation in the blood stream. The basis of the immunohematologic tests is the interaction between antigens and antibodies that causes hemagglutination. The identification of antibodies and antigens is of fundamental importance for the transfusional routine. This agglutination is induced by decreasing the zeta-potential through the introduction of artificial potential substances. This report proposes the use of the optical tweezers to measure the membrane viscosity, the cell adhesion, the zeta-potential and the size of the double layer of charges (CLC) formed around the cell in an electrolytic solution. The adhesion was quantified by slowly displacing two RBCs apart until the disagglutination. The CLC was measured using the force on the bead attached to a single RBC in response to an applied voltage. The zeta-potential was obtained by measuring the terminal velocity after releasing the RBC from the optical trap at the last applied voltage. For the membrane viscosity experiment, we trapped a bead attached to RBCs and measured the force to slide one RBC over the other as a function of the relative velocity. After we tested the methodology, we performed measurements using antibody and potential substances. We observed that this experiment can provide information about cell agglutination that helps to improve the tests usually performed in blood banks. We also believe that this methodology can be applied for measurements of zeta-potentials in other kind of samples.

  8. Latex agglutination inhibition card test for gentamicin assay: clinical evaluation and comparison with radioimmunoassay and bioassay.

    PubMed Central

    Standiford, H C; Bernstein, D; Nipper, H C; Caplan, E; Tatem, B; Hall, J S; Reynolds, J

    1981-01-01

    Gentamicin levels were determined in 100 serum specimens by a new latex agglutination inhibition card test, a radioimmunoassay (RIA), and a bioassay. Correlation coefficients determined by linear regression analysis demonstrated that the levels obtained by the latex agglutination inhibition card test had a high degree of correlation with the RIA and could be performed much faster and more economically when processing small numbers of specimens. The bioassay had a slightly lower degree of correlation with both the RIA and the latex test and was adversely influenced by concurrently administered antibiotics which could not be eliminated by beta-lactamase. When measuring gentamicin concentrations above 2 micrograms/ml, the coefficient of variation was less than 14% for the latex agglutination assay compared with 15% for the bioassay and 12% for RIA. The latex agglutination inhibition card test is a rapid, accurate, specific, and reproducible method for monitoring gentamicin levels in patients and is particularly applicable for laboratories processing small numbers of specimens. PMID:7247384

  9. A study of the transport and immobilisation mechanisms of human red blood cells in a paper-based blood typing device using confocal microscopy.

    PubMed

    Li, Lizi; Tian, Junfei; Ballerini, David; Li, Miaosi; Shen, Wei

    2013-09-07

    Recent research on the use of bioactive paper for human blood typing has led to the discovery of a new method for identifying the haemagglutination of red blood cells (RBCs). When a blood sample is introduced onto paper treated with the grouping antibodies, RBCs undergo haemagglutination with the corresponding grouping antibodies, forming agglutinated cell aggregates in the paper. A subsequent washing of the paper with saline buffer could not remove these aggregates from the paper; this phenomenon provides a new method for rapid, visual identification of the antibody-specific haemagglutination reactions and thus the determination of the blood type. This study aims to understand the mechanism of RBC immobilization inside the paper which follows haemagglutination reactions. Confocal microscopy is used to observe the morphology of the free and agglutinated RBCs that are labelled with FITC. Chromatographic elution patterns of both agglutinated and non-agglutinated RBCs are studied to gain insight into the transport behaviour of free RBCs and agglutinated aggregates. This work provides new information about RBC haemagglutination inside the fibre network of paper on a microscopic level, which is important for the future design of paper-based blood typing devices with high sensitivity and assaying speed.

  10. Preliminary evaluation of a gel tube agglutination major cross-match method in dogs.

    PubMed

    Villarnovo, Dania; Burton, Shelley A; Horney, Barbara S; MacKenzie, Allan L; Vanderstichel, Raphaël

    2016-09-01

    A major cross-match gel tube test is available for use in dogs yet has not been clinically evaluated. This study compared cross-match results obtained using the gel tube and the standard tube methods for canine samples. Study 1 included 107 canine sample donor-recipient pairings cross-match tested with the RapidVet-H method gel tube test and compared results with the standard tube method. Additionally, 120 pairings using pooled sera containing anti-canine erythrocyte antibody at various concentrations were tested with leftover blood from a hospital population to assess sensitivity and specificity of the gel tube method in comparison with the standard method. The gel tube method had a good relative specificity of 96.1% in detecting lack of agglutination (compatibility) compared to the standard tube method. Agreement between the 2 methods was moderate. Nine of 107 pairings showed agglutination/incompatibility on either test, too few to allow reliable calculation of relative sensitivity. Fifty percent of the gel tube method results were difficult to interpret due to sample spreading in the reaction and/or negative control tubes. The RapidVet-H method agreed with the standard cross-match method on compatible samples, but detected incompatibility in some sample pairs that were compatible with the standard method. Evaluation using larger numbers of incompatible pairings is needed to assess diagnostic utility. The gel tube method results were difficult to categorize due to sample spreading. Weak agglutination reactions or other factors such as centrifuge model may be responsible. © 2016 American Society for Veterinary Clinical Pathology.

  11. Process to create simulated lunar agglutinate particles

    NASA Technical Reports Server (NTRS)

    Gustafson, Robert J. (Inventor); Gustafson, Marty A. (Inventor); White, Brant C. (Inventor)

    2011-01-01

    A method of creating simulated agglutinate particles by applying a heat source sufficient to partially melt a raw material is provided. The raw material is preferably any lunar soil simulant, crushed mineral, mixture of crushed minerals, or similar material, and the heat source creates localized heating of the raw material.

  12. Prevalance of ABO and Rhesus Blood Groups in Blood Donors: A Study from a Tertiary Care Teaching Hospital of Kumaon Region of Uttarakhand.

    PubMed

    Garg, Parul; Upadhyay, Saloni; Chufal, Sanjay Singh; Hasan, Yuman; Tayal, Ishwer

    2014-12-01

    Backround: ABO and Rhesus (Rh) blood group antigens are hereditary characters and are useful in population genetic studies, in resolving medico-legal issues and more importantly for the immunologic safety of blood during transfusion. This study is aimed to determine the distribution pattern of the ABO and Rh blood groups among blood donors in Kumaon region of Uttarakhand and compare it with other data from similar studies within the India and all over the world. It is a retrospective study carried out at blood bank of Shushila Tewari Hospital of Government Medical College, Haldwani from January 2012 to December 2013. The study was conducted on 12,701 blood donors. ABO and Rh typing was done using slide agglutination method with antisera ABO and Rh (Tulip diagnostics ltd). Doubtful cases were confirmed by tube agglutination method and reverse grouping using known pooled A and B cells. The age group and sex of donors, frequency of ABO and Rh blood groups were reported in simple percentages. The predominant donors belonged to age group between 18-35years (84.28%). Male donors were more than female donors, ratio being 352:1. Replacement donors (99.71%) were much more than voluntary donors (0.91%). The most common blood group was B (32.07%) and least common being AB (10.53%). Blood group 'O' and 'A' had same frequency. The prevalence of Rhesus positive and negative distribution in the studied population was 94.49% and 5.51% respectively. Blood group frequency with respect to ABO and Rhesus positive was found to be shown by formula B> O>A >AB. The frequency for ABO and Rhesus negative was given by the formula B>A>O>AB. Knowledge of frequencies of the different blood groups is very important for blood banks and transfusion service policies that could contribute significantly to the National Health System.

  13. [Influence of S-nitrosoglutathione on agglutination and nitric oxide concentration in frozen platelets].

    PubMed

    Wu, Tao; Liu, Jing-Han; Li, Hui; Zhou, Wu; Wang, Shu-Ying

    2012-04-01

    The aim of this study was to investigate the influence of S-nitrosoglutathione (GSNO) on agglutination and nitric oxide (NO) concentration in frozen platelets. The agglutination of platelets was detected by using platelet agglutination apparatus, the level of NO in platelets was detected by the nitrate enzyme reduction method. The results showed that the rates of agglutination in freeze platelets and frozen platelets treated with GSNO were (35.47 ± 2.93) and (24.43 ± 3.07), which were significantly lower than that in fresh liquid platelets (63.44 ± 2.96). The level of NO concentration in frozen platelets was (22.16 ± 6.38), which was significantly lower than that in fresh liquid platelets (31.59 ± 16.88). The level of NO concentration in frozen platelets treated with GSNO was (45.64 ± 6.31), which was significantly higher than that in fresh liquid platelets (P < 0.01). It is concluded that GSNO increases the concentration of NO in frozen platelets, inhibits platelet activation and maintains platelet function, thus GSNO can be used as a frozen protective agent.

  14. Detection of Salmonella enterica serovar Enteritidis (SE) Antibodies in Serum Using A Polystyrene Bead/SE Flagella Agglutination Assay

    USDA-ARS?s Scientific Manuscript database

    Serologic screening of flocks can be an important method to detect Salmonella enteritidis (SE) infections but can be labor intensive or lack specificity. Our goal was to develop a rapid agglutination assay using SE flagella adsorbed to polystyrene beads as a simple, relatively specific test to dete...

  15. MEMS reagent and sample handling procedure: Feasibility of viral antibody detection by passive immune agglutination

    NASA Technical Reports Server (NTRS)

    Bailey, G. D.; Tenoso, H. J.

    1975-01-01

    An attempt was made to develop a test requiring no preadsorption steps for the assessment of antibodies to rubella and mumps viruses using the passive immune agglutination (PIA) method. Both rubella and mumps antigens and antibodies were prepared. Direct PIA tests, using rubella antigen-coated beads, and indirect PIA tests, using rubella antibody-coated beads, were investigated. Attempts, using either method, were unsuccessful. Serum interference along with nonspecific agglutination of beads by the rubella antigen resulted in no specific response under the test conditions investigated. A new, highly sensitive approach, the enzyme immunoassay (EIA) test system, is recommended to overcome the nonspecificity. This system is a logical outgrowth of some of the solid phase work done on MEMS and represents the next generation tests system that can be directly applied to early disease detection and monitoring.

  16. The role of RhD agglutination for the detection of weak D red cells by anti-D flow cytometry.

    PubMed

    Grey, D E; Davies, J I; Connolly, M; Fong, E A; Erber, W N

    2005-04-01

    Anti-D flow cytometry is an accurate method for quantifying feto-maternal haemorrhage (FMH). However, weak D red cells with <1000 RhD sites are not detectable using this methodology but are immunogenic. As quantitation of RhD sites is not practical, an alternative approach is required to identify those weak D fetal red cells where anti-D flow cytometry is inappropriate. We describe a simple algorithm based on RhD agglutination and flow cytometry peak separation. All weak D (n = 34) gave weak agglutination with RUM-1 on immediate spin (grading

  17. A comparison of sperm agglutination and immobilization assays with a quantitative ELISA for anti-sperm antibody in serum.

    PubMed

    Lynch, D M; Leali, B A; Howe, S E

    1986-08-01

    An enzyme-linked immunosorbent assay (ELISA) that quantitates antisperm antibody in serum was compared with standard sperm agglutination and immobilization assays with the use of sera from 40 normal and 292 subfertile individuals. Quantitation of the assay was accomplished by standardizing assay parameters, including the incorporation of a standard reference curve, the number of whole target sperm, the optimal dilution of serum, the selection of microtiter plate, and the time and temperatures involved in the adsorption and incubation phases. With this method, the level of antisperm antibody binding to target sperm in 40 normal fertile individuals was found to be 2.3 (+/- 1.1 standard deviation [SD]) fg immunoglobulin (Ig)/sperm. An increased mean level of 7.4 +/- 3.7 fg Ig/sperm was determined in 84 infertile patients with positive agglutination and/or immobilization tests. In 208 individuals with negative agglutination and immobilization tests the mean concentration of antisperm antibody was 2.5 +/- 1.3 fg Ig/sperm. Postvasectomy patients assayed by this method had a mean Ig binding value of 7.1 +/- 2.4 fg Ig/sperm. The infertile group with positive agglutination and/or immobilization tests had a significantly higher mean antisperm antibody level than the normal fertile group, according to the Student's t-test for independent samples (P less than 0.001). This indirect serum-based assay reproducibly quantitates antisperm antibody binding to whole target sperm, suggests the normal and abnormal levels of antisperm antibody, and correlates with standard functional assays.

  18. Diagnosis of toxoplasmic encephalitis in patients with acquired immunodeficiency syndrome by using a new serologic method.

    PubMed Central

    Suzuki, Y; Israelski, D M; Dannemann, B R; Stepick-Biek, P; Thulliez, P; Remington, J S

    1988-01-01

    The present study was performed to develop a serological method for diagnosing toxoplasmic encephalitis in patients with acquired immunodeficiency syndrome (AIDS). The trophozoite form of Toxoplasma gondii, fixed with either Formalin or acetone, was used in a modification of an agglutination method previously shown to differentiate between the acute and the chronic (latent) stages of infection with toxoplasma in immunologically normal persons. By using these antigens in separate tests and evaluating the data for statistical significance, 70% of patients with AIDS with biopsy-proven toxoplasmic encephalitis were distinguished from control, ambulatory patients with AIDS with toxoplasma antibodies but without signs or symptoms of central nervous system involvement. In a separate study, the agglutination tests identified from controls 84% of patients with AIDS with two or more brain lesions detected by computed-tomographic or magnetic-resonance-imaging scans and suspected of having toxoplasmic encephalitis. Thus, these agglutination tests should prove valuable for the noninvasive diagnosis of toxoplasmic encephalitis in patients with AIDS. PMID:3230132

  19. Comparison of optomagnetic and AC susceptibility readouts in a magnetic nanoparticle agglutination assay for detection of C-reactive protein.

    PubMed

    Fock, Jeppe; Parmvi, Mattias; Strömberg, Mattias; Svedlindh, Peter; Donolato, Marco; Hansen, Mikkel Fougt

    2017-02-15

    There is an increasing need to develop biosensor methods that are highly sensitive and that can be combined with low-cost consumables. The use of magnetic nanoparticles (MNPs) is attractive because their detection is compatible with low-cost disposables and because application of a magnetic field can be used to accelerate assay kinetics. We present the first study and comparison of the performance of magnetic susceptibility measurements and a newly proposed optomagnetic method. For the comparison we use the C-reactive protein (CRP) induced agglutination of identical samples of 100nm MNPs conjugated with CRP antibodies. Both methods detect agglutination as a shift to lower frequencies in measurements of the dynamics in response to an applied oscillating magnetic field. The magnetic susceptibility method probes the magnetic response whereas the optomagnetic technique probes the modulation of laser light transmitted through the sample. The two techniques provided highly correlated results upon agglutination when they measure the decrease of the signal from the individual MNPs (turn-off detection strategy), whereas the techniques provided different results, strongly depending on the read-out frequency, when detecting the signal due to MNP agglomerates (turn-on detection strategy). These observations are considered to be caused by differences in the volume-dependence of the magnetic and optical signals from agglomerates. The highest signal from agglomerates was found in the optomagnetic signal at low frequencies. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Evaluation of different methods to detect methicillin resistance in Staphylococcus aureus (MRSA).

    PubMed

    Alipour, Farzad; Ahmadi, Malahat; Javadi, Shahram

    2014-01-01

    The studies suggest that dogs living with human are potential risk of becoming MRSA carrier and increased risk of infections caused by MRSA. Phenotypic methods to detect methicillin resistance in Staphylococcus aureus (MRSA) are inadequate. The objective of the present study was to determine methicillin resistance in S. aureus by phenotypic susceptibility test (oxacillin disk diffusion, cefoxitin disk diffusion, oxacillin screen agar) and molecular methods (PCR as a gold standard) and the latex agglutination test for the detection of PBP2a and to evaluate the results of these tests for its sensitivity and specificity. A total of 100 swab samples were taken from muzzle site, in more contact with human, of dogs and MRSA were isolated. Oxacillin (1 μg), cefoxitin (30 μg) disk diffusion and oxacillin screen agar method were used. The isolates were also subjected to latex agglutination test for detection of PBP2a and PCR to detect mecA gene. By PCR 37% of isolates show the presence of mecA. Latex agglutination was found to be the most sensitive (97.29%) and cefoxitin disk diffusion to be the most specific (96.82%) tests for detection of MRSA. Our finding showed that combining oxacillin screen agar or cefoxitin disk diffusion with latex agglutination improves sensitivity and specificity to detect methicillin resistance S. aureus (MRSA) isolates. Copyright © 2014 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  1. [The incidence of agglutination and its influence on sperm quality and fertility of boar semen].

    PubMed

    Bollwein, Heinrich; Petschow, Karola; Weber, Frank; Leiding, Claus; Stolla, Rudolf

    2004-01-01

    The aim of this study was to examine the incidence of sperm agglutinations and their relationships with sperm quality and fertility. Semen samples of 40 boars of an AI-station were investigated. Nineteen of the 40 investigated boars showed a constantly low (< 10% agglutinated sperm), 3 an intermediate (10-20%) and 6 boars a high level (> 20%) of agglutination in raw semen. The degree of agglutination in sperm samples of 12 boars varied distinctly during the investigation period. During summer more (P < 0.05) agglutinated sperm were observed (11.0 +/- 11.6%) than during winter (6.2 +/- 7.3%). There was no association between bacterial contamination and incidence of agglutinations (P > 0.05). After dilution in extender the percentage of agglutinated sperm decreased from 6.2 +/- 7.3% to 1.1 +/- 1.4% (P < 0.0001). Twenty-four hours after dilution the percentage of progressively motile sperm was 7.4% lower (P < 0.05) in ejaculates with an initially high degree of agglutination (> 20% agglutinated sperm) compared to samples with an initially low degree of agglutinated sperm (< 10%). Plasma membrane integrity, mitochondrial membrane potential, acrosome reaction and chromatin structure were independent (P > 0.05) from the level of agglutination. Fertility data did not differ (P > 0.05) between boars with low and high numbers of agglutinated sperm in raw semen. The results show that there are individual, ejaculatory and seasonal variations in the incidence and degree of agglutination. Agglutinations have a negative effect on motility of sperm and disappear to a large extent after dilution in sperm extender. They have no negative consequences on fertility.

  2. Chemical aspects of agglutinate formation - Relationships between agglutinate composition and the composition of the bulk soil. [lunar surface composition

    NASA Technical Reports Server (NTRS)

    Via, W. N.; Taylor, L. A.

    1976-01-01

    Attention is centered on the nature and intensity of geochemical fractionation accompanying agglutination of several size fractions of the immature Apollo-16 soil sample 67460, from North Ray Crater. The soil features coarse mean grain size about 150 microns, low (20 wt.%) magnetic agglutinate content, and a bimodal grain size distribution. The magnetic fraction included both agglutinates and magnetic non-agglutinates (glass-free microbreccias with 30-60 micron native FeNi grains hosted in a matrix of pyroxene, ilmenite, and olivine). The separation process residue contained nonmagnetic agglutinates with compositions near pure plagioclase. The magnetic agglutinate fraction appears selectively enriched in ferromagnesian elements to the partial exclusion of plagioclase elements. Agglutinate glass chemistry based solely on magnetic separation is deprecated on the basis of the results.

  3. Bacterial meningitis in children under 15 years of age in Nepal.

    PubMed

    Shrestha, Rajani Ghaju; Tandukar, Sarmila; Ansari, Shamshul; Subedi, Akriti; Shrestha, Anisha; Poudel, Rekha; Adhikari, Nabaraj; Basnyat, Shital Raj; Sherchand, Jeevan Bahadur

    2015-08-19

    Bacterial meningitis in children is a life-threatening problem resulting in severe morbidity and mortality. For the prompt initiation of antibacterial therapy, rapid and reliable diagnostic methods are of utmost importance. Therefore, this study was designed to find out the rate of bacterial pathogens of meningitis from suspected cases by performing conventional methods and latex agglutination. A descriptive type of study was carried out from May 2012 to April 2013. Cerebrospinal fluid (CSF) specimens from 252 suspected cases of meningitis were subjected for Gram staining, bacterial culture and latex agglutination test. The identification of growth of bacteria was done following standard microbiological methods recommended by American Society for Microbiology. Antibiotic sensitivity testing was done by modified Kirby-Bauer disk diffusion method. From the total 252 suspected cases, 7.2 % bacterial meningitis was revealed by Gram staining and culture methods whereas latex agglutination method detected 5.6 %. Gram-negative organisms contributed the majority of the cases (72.2 %) with Haemophilus influenzae as the leading pathogen for meningitis. Overall, 33.3 % mortality rate was found. In conclusion, a significant rate of bacterial meningitis was found in this study prompting concern for national wide surveillance.

  4. Serotyping reanalysis of unserotypable Actinobacillus pleuropneumoniae isolates by agar gel diffusion test.

    PubMed

    Morioka, Ayako; Shimazaki, Yoko; Uchiyama, Mariko; Suzuki, Shoko

    2016-05-03

    We observed increasing unserotypable (UT) Actinobacillus pleuropneumoniae isolates using agar gel diffusion (AGD) test. To reanalyze their serovar, we performed rapid slide agglutination (RSA) test and multiplex PCR for 47 UT isolates. Of these, 25 were serovar 1 (UT-serovar 1), 20 were serovar 2 (UT-serovar 2) and 2 were serovar 15 (UT-serovar 15). We examined serotyping antigen extraction temperature to determine heat influence. UT-serovar 1 and 15 were influenced by heat, because their precipitation lines were observed in the case of low antigen extraction temperature. To investigate the relationship between antigenicity and genotype, we performed pulsed-field gel electrophoresis (PFGE) analysis using UT-serovar 2 and 15. The predominant PFGE pattern of UT-serovar 2 was identical to that of serovar 2.

  5. Serotyping reanalysis of unserotypable Actinobacillus pleuropneumoniae isolates by agar gel diffusion test

    PubMed Central

    MORIOKA, Ayako; SHIMAZAKI, Yoko; UCHIYAMA, Mariko; SUZUKI, Shoko

    2016-01-01

    We observed increasing unserotypable (UT) Actinobacillus pleuropneumoniae isolates using agar gel diffusion (AGD) test. To reanalyze their serovar, we performed rapid slide agglutination (RSA) test and multiplex PCR for 47 UT isolates. Of these, 25 were serovar 1 (UT-serovar 1), 20 were serovar 2 (UT-serovar 2) and 2 were serovar 15 (UT-serovar 15). We examined serotyping antigen extraction temperature to determine heat influence. UT-serovar 1 and 15 were influenced by heat, because their precipitation lines were observed in the case of low antigen extraction temperature. To investigate the relationship between antigenicity and genotype, we performed pulsed-field gel electrophoresis (PFGE) analysis using UT-serovar 2 and 15. The predominant PFGE pattern of UT-serovar 2 was identical to that of serovar 2. PMID:26726101

  6. Lack of chemical fractionation in major and minor elements during agglutinate formation. [in lunar soil

    NASA Technical Reports Server (NTRS)

    Hu, H.-N.; Taylor, L. A.

    1977-01-01

    Rhodes et al. (1975, 1976) and Adams et al. (1975) have reported that the agglutinate fraction of the soils on the lunar surface displays a marked enrichment in Fe, Mg, Ti, K, and La, and a depletion in Ca, Na, Al, and Eu, relative to the bulk soils. The reported investigation is concerned with a testing of the theory of chemical fractionation involving magnetic separation which was developed in connection with these findings. Soils 64421 and 71501 were sieved and the magnetic fractions separated according to the method developed by Adams and McCord (1973). Analyses of agglutinitic glass did not indicate any appreciable chemical fractionation for the major and minor elements accompanying the agglutination process. It was found that most, if not all fractionations reported can be accounted for completely by the magnetic nonagglutinate impurities in the agglutinate fraction. It is, therefore, concluded that there appears to be no reason to make use of any chemical fractionation theory, whose validity remains to be demonstrated.

  7. Direct detection of methicillin resistance in Staphylococcus aureus in blood culture broth by use of a penicillin binding protein 2a latex agglutination test.

    PubMed

    Qian, Qinfang; Venkataraman, Lata; Kirby, James E; Gold, Howard S; Yamazumi, Toshiaki

    2010-04-01

    We studied the utility of performing a penicillin binding protein 2a latex agglutination (PBP-LA) assay directly on Bactec blood culture broth samples containing Staphylococcus aureus to rapidly detect methicillin resistance. The sensitivity, specificity, positive predictive value, and negative predictive value of this method were 94.1%, 97.5%, 98%, and 92.9%, respectively.

  8. Loop-Mediated Isothermal Amplification of the sefA Gene for Rapid Detection of Salmonella Enteritidis and Salmonella Gallinarum in Chickens.

    PubMed

    Gong, Jiansen; Zhuang, Linlin; Zhu, Chunhong; Shi, Shourong; Zhang, Di; Zhang, Linji; Yu, Yan; Dou, Xinhong; Xu, Bu; Wang, Chengming

    2016-04-01

    Salmonella spp. pose a threat to both human and animal health, with more than 2600 serovars having been reported to date. Salmonella serovars are usually identified by slide agglutination tests, which are labor intensive and time consuming. In an attempt to develop a more rapid screening method for the major poultry Salmonella serovars, we developed a loop-mediated isothermal amplification (LAMP) assay, which directly detected the sefA gene, a fimbrial operon gene existing in several specific serovars of Salmonella enterica including the major poultry serovars, namely Salmonella enterica serovar Enteritidis (Salmonella Enteritidis) and Salmonella enterica serovar Gallinarum (Salmonella Gallinarum). With the 177 bacterial strains we tested, positive reactions were only observed with 85 strains of serovar Salmonella Enteritidis and Salmonella Gallinarum. The detection limit of the LAMP assay was 4 CFU/reaction with genomic DNAs of Salmonella Enteritidis (ATCC 13076) from pure culture and 400 CFU/ reaction with DNA extracted from spiked chicken feces. The LAMP assay was more sensitive than conventional culture, especially without enrichment, in detecting Salmonella Enteritidis (CMCC 50041) in the spiked fecal samples. The results show the sefA LAMP method is a rapid, sensitive, specific, and practical method for directly detection of Salmonella Enteritidis and Salmonella Gallinarum in chickens. The sefA LAMP assay can potentially serve as new on-site diagnostics in the poultry industry.

  9. Methicillin-Resistant Staphylococcus aureus: Comparison of Susceptibility Testing Methods and Analysis of mecA-Positive Susceptible Strains

    PubMed Central

    Sakoulas, George; Gold, Howard S.; Venkataraman, Lata; DeGirolami, Paola C.; Eliopoulos, George M.; Qian, Qinfang

    2001-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is responsible for an increasing number of serious nosocomial and community-acquired infections. Phenotypic heterogeneous drug resistance (heteroresistance) to antistaphylococcal beta-lactams affects the results of susceptibility testing. The present study compared the MRSA-Screen latex agglutination test (Denka Seiken Co., Ltd., Tokyo, Japan) for detection of PBP 2a with agar dilution, the VITEK-1 and VITEK-2 systems (bioMérieux, St. Louis, Mo.), and the oxacillin agar screen test for detection of MRSA, with PCR for the mecA gene used as the “gold standard” assay. Analysis of 107 methicillin-susceptible S. aureus (MSSA) isolates and 203 MRSA isolates revealed that the MRSA-Screen latex agglutination test is superior to any single phenotype-based susceptibility testing method, with a sensitivity of 100% and a specificity of 99.1%. Only one isolate that lacked mecA was weakly positive by the MRSA-Screen latex agglutination test. This isolate was phenotypically susceptible to oxacillin and did not contain the mecA gene by Southern blot hybridization. The oxacillin agar screen test, the VITEK-1 system, the VITEK-2 system, and agar dilution showed sensitivities of 99.0, 99.0, 99.5, and 99%, respectively, and specificities of 98.1, 100, 97.2, and 100%, respectively. The differences in sensitivity or specificity were not statistically significant. Oxacillin bactericidal assays showed that mecA- and PBP 2a-positive S. aureus isolates that are susceptible to antistaphylococcal beta-lactams by conventional methods are functionally resistant to oxacillin. We conclude that the accuracy of the MRSA-Screen latex agglutination method for detection of PBP 2a approaches the accuracy of PCR and is more accurate than any susceptibility testing method used alone for the detection of MRSA. PMID:11682512

  10. Molecular typing of Sarcocystis neurona: current status and future trends.

    PubMed

    Elsheikha, Hany M; Mansfield, Linda S

    2007-10-21

    Sarcocystis neurona is an important protozoal pathogen because it causes the serious neurological disease equine protozoal myeloencephalitis (EPM). The capacity of this organism to cause a wide spectrum of neurological signs in horses and the broad geographic distribution of observed cases in the Americas drive the need for sensitive, reliable and rapid typing methods to characterize strains. Various molecular methods have been developed and used to diagnose EPM due to S. neurona, to identify S. neurona isolates and to determine the heterogeneity and evolutionary relatedness within this species and related Sarcocystis spp. These methods included sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), immuno-fluorescent assay (IFA), slide agglutination test (SAT), SnSAG-specific ELISA, random amplified polymorphic DNA (RAPD), PCR-based restriction fragment length polymorphism (RFLP), amplified fragment length polymorphism (AFLP) fingerprinting, and sequence analysis of surface protein genes, ribosomal genes, microsatellite alleles and other molecular markers. Here, the utility of these molecular methods is reviewed and evaluated with respect to the need for molecular approaches that utilize well-characterized polymorphic, simple, independent, and stable genetic markers. These tools have the potential to add to knowledge of the genetic population structure of S. neurona and to provide new insights into the pathogenesis of EPM and S. neurona epidemiology. In particular, these methods provide new tools to address the hypothesis that particular genetic variants are associated with adverse clinical outcomes (severe pathotypes). The ultimate goal is to utilize them in future studies to improve treatment and prevention strategies.

  11. Klebsiella pneumoniae type 3 fimbriae agglutinate yeast in a mannose-resistant manner.

    PubMed

    Stahlhut, Steen G; Struve, Carsten; Krogfelt, Karen A

    2012-03-01

    The ability of bacterial pathogens to express different fimbrial adhesins plays a significant role in virulence. Thus, specific detection of fimbrial expression is an important task in virulence characterization and epidemiological studies. Most clinical Klebsiella pneumoniae isolates express type 1 and type 3 fimbriae, which are characterized by mediation of mannose-sensitive agglutination of yeast cells and agglutination of tannic acid-treated ox red blood cells (RBCs), respectively. It has been observed that K. pneumoniae isolates agglutinate yeast cells and commercially available sheep RBCs in a mannose-resistant manner. Thus, this study was initiated to identify the adhesin involved. Screening of a mutant library surprisingly revealed that the mannose-resistant agglutination of yeast and sheep RBCs was mediated by type 3 fimbriae. Specific detection of type 1 fimbriae expression in K. pneumoniae was feasible only by the use of guinea pig RBCs. This was further verified by the use of isogenic fimbriae mutants and by cloning and expressing K. pneumoniae fimbrial gene clusters in Escherichia coli. Yeast agglutination assays are commonly used to detect type 1 fimbriae expression but should not be used for bacterial species able to express type 3 fimbriae. For these species, the use of guinea pig blood for specific type 1 fimbriae detection is essential. The use of commercially available sheep RBCs or yeast is an easy alternative to traditional methods to detect type 3 fimbriae expression. Easy and specific detection of expression of type 1 and type 3 fimbriae is essential in the continuous characterization of these important adhesive virulence factors present in members of the Enterobacteriaceae.

  12. STUDIES ON THE BIOLOGY OF STREPTOCOCCUS

    PubMed Central

    Stevens, Franklin A.; Dochez, A. R.

    1926-01-01

    1. Strains of hemolytic streptococci isolated from cases of erysipelas agglutinate in a high percentage of instances with erysipelas immune sera. When agglutination occurs with one serum, the strain usually agglutinates with all other erysipelas sera. 2. Erysipelas immune sera agglutinate strains from erysipelas in a higher percentage of instances than they agglutinate scarlatinal strains. 3. Strains from miscellaneous pyogenic infections may agglutinate in these sera, but the percentage of positive reactions is low and a strain usually agglutinates in but one or two of several sera. 4. Erysipelas strains which agglutinate in immune sera are not necessarily identical, although identical strains may occur. Similarly, identical strains may occur among scarlatinal strains agglutinated by scarlatinal immune sera. 5. Erysipelas strains form a closely related group of hemolytic streptococci. Scarlatinal strains form an equally compact group. The two groups are related antigenically but less closely related than the strains within the groups. These groups are related to pyogenic strains, but less closely than they are related to each other. 6. Erysipelas, scarlatinal, or pyogenic strains which agglutinate in erysipelas or scarlatinal sera are capable of absorbing the agglutinin for all other strains except the homologous strain and strains identical with it. Strains identical with the homologous strain absorb the agglutinin completely. 7. Erysipelas or scarlatinal strains may absorb the common group agglutinin from their respective sera, when they are incapable of agglutination in these sera. 8. The agglutinogen is probably of complex or composite nature, with characteristic variations in the scarlet fever and erysipelas groups. PMID:19869130

  13. [Methicillin resistance detection in Staphylococcus aureus: comparison between conventional methods and MRSA-Screen latex agglutination technique].

    PubMed

    Soloaga, R; Corso, A; Gagetti, P; Faccone, D; Galas, M

    2004-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is a significant pathogen that has emerged over the last four decades, causing both nosocomial and community-acquired infections. Rapid and accurate detection of methicillin resistance in S. aureus is important for the use of appropriate antimicrobial therapy and for the control of nosocomial spread of MRSA strains. We evaluated the efficiency of conventional methods for detection of methicillin resistance such as the disk diffusion, agar dilution, oxacillin agar screen test, and the latex agglutination test MRSA-Screen latex, in 100 isolates of S. aureus, 79 mecA positive and 21 mecA negative. The MRSA-Screen latex (Denka Seiken, Niigata, Japón), is a latex agglutination method that detects the presence of PLP-2a, product of mecA gene in S. aureus. The PCR of the mecA gene was used as the "gold standard" for the evaluation of the different methods tested. The percentages of sensitivity and specificity were as follows: disk difusión 97 and 100%, agar dilution 97 and 95%, oxacillin agar screen test 100 and 100%, and MRSA-Screen latex, 100 and 100 %. All methods presented high sensitivity and specificity, but MRSA-Screen latex had the advantage of giving a reliable result, equivalent to PCR, in only 15 minutes.

  14. Lab-on-a-disc agglutination assay for protein detection by optomagnetic readout and optical imaging using nano- and micro-sized magnetic beads.

    PubMed

    Uddin, Rokon; Burger, Robert; Donolato, Marco; Fock, Jeppe; Creagh, Michael; Hansen, Mikkel Fougt; Boisen, Anja

    2016-11-15

    We present a biosensing platform for the detection of proteins based on agglutination of aptamer coated magnetic nano- or microbeads. The assay, from sample to answer, is integrated on an automated, low-cost microfluidic disc platform. This ensures fast and reliable results due to a minimum of manual steps involved. The detection of the target protein was achieved in two ways: (1) optomagnetic readout using magnetic nanobeads (MNBs); (2) optical imaging using magnetic microbeads (MMBs). The optomagnetic readout of agglutination is based on optical measurement of the dynamics of MNB aggregates whereas the imaging method is based on direct visualization and quantification of the average size of MMB aggregates. By enhancing magnetic particle agglutination via application of strong magnetic field pulses, we obtained identical limits of detection of 25pM with the same sample-to-answer time (15min 30s) using the two differently sized beads for the two detection methods. In both cases a sample volume of only 10µl is required. The demonstrated automation, low sample-to-answer time and portability of both detection instruments as well as integration of the assay on a low-cost disc are important steps for the implementation of these as portable tools in an out-of-lab setting. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Diagnosis of myocardial infarction based on lectin-induced erythrocyte agglutination: a feasibility study

    NASA Astrophysics Data System (ADS)

    Bocsi, József; Nieschke, Kathleen; Mittag, Anja; Reichert, Thomas; Laffers, Wiebke; Marecka, Monika; Pierzchalski, Arkadiusz; Piltz, Joachim; Esche, Hans-Jürgen; Wolf, Günther; Dähnert, Ingo; Baumgartner, Adolf; Tarnok, Attila

    2014-03-01

    Myocardial infarction (MI) is an acute life-threatening disease with a high incidence worldwide. Aim of this study was to test lectin-carbohydrate binding-induced red blood cell (RBC) agglutination as an innovative tool for fast, precise and cost effective diagnosis of MI. Five lectins (Ricinus communis agglutinin (RCA), Phaseolus vulgaris erythroagglutinin (PHA), Datura stramonium agglutinin (DSA), Artocarpus agglutinin (ArA), Triticum agglutinin (TA)) were tested for ability to differentiate between agglutination characteristics in patients with MI (n = 101) or angina pectoris without MI (AP) (n = 34) and healthy volunteers (HV) as control (n =68) . RBC agglutination was analyzed by light absorbance of a stirred RBC suspension in the green to red light spectrum in an agglutimeter (amtec, Leipzig, Germany) for 15 min after lectin addition. Mean cell count in aggregates was estimated from light absorbance by a mathematical model. Each lectin induced RBC agglutination. RCA led to the strongest RBC agglutination (~500 RBCs/aggregate), while the others induced substantially slower agglutination and lead to smaller aggregate sizes (5-150 RBCs/aggregate). For all analyzed lectins the lectin-induced RBC agglutination of MI or AP patients was generally higher than for HV. However, only PHA induced agglutination that clearly distinguished MI from HV. Variance analysis showed that aggregate size after 15 min. agglutination induced by PHA was significantly higher in the MI group (143 RBCs/ aggregate) than in the HV (29 RBC-s/aggregate, p = 0.000). We hypothesize that pathological changes during MI induce modification of the carbohydrate composition on the RBC membrane and thus modify RBC agglutination. Occurrence of carbohydrate-lectin binding sites on RBC membranes provides evidence about MI. Due to significant difference in the rate of agglutination between MI > HV the differentiation between these groups is possible based on PHA-induced RBC-agglutination. This novel assay could serve as a rapid, cost effective valuable new tool for diagnosis of MI.

  16. Use of two conventional staining methods to assess the acrosomal status of stallion spermatozoa.

    PubMed

    Runcan, E E; Pozor, M A; Zambrano, G L; Benson, S; Macpherson, M L

    2014-07-01

    The acrosome is a highly specialised region of the spermatozoon that is essential for fertilisation. Defects or dysfunction of this structure have been associated with fertility problems in man and various domestic species including stallions. Current methods of evaluating the acrosome of stallion spermatozoa are time consuming and require specialised equipment, which is cost prohibitive to the average practitioner. To evaluate 2 conventional stains (Dip Quick and Spermac) and determine their usefulness in assessing acrosome integrity in stallions as compared with specific acrosomal labelling with a fluorescein-conjugated lectin - a method that has been validated for acrosome status evaluation in stallions. In vivo experimental design. Semen from 6 mature Miniature horse stallions of known fertility was collected on 5 separate occasions. To increase the number of reacted acrosomes, portions of each ejaculate were incubated with the calcium ionophore, A23187. Ejaculates were divided and semen samples were processed according to recommendations for fluorescein-conjugated peanut lectin, Pisum sativum agglutin, Dip Quick, and Spermac staining methods. Slides were evaluated independently by 2 separate investigators. Spermatozoa were classified as having intact, reacting, reacted or defective acrosomes. All parameters obtained by both investigators, using all 3 staining methods were highly correlated (P<0.001). There was no statistical difference (P>0.05) between investigators or staining method for the percentages of intact or reacted acrosomes. However, there was a significant difference between investigators and staining methods for determining reacting acrosome percentages (P<0.05). Dip Quick and Spermac stains are useful for determining intact vs. reacted acrosomes for stallion spermatozoa. © 2013 EVJ Ltd.

  17. Naturally occurring pepsin agglutinators in the serum of subhuman primates*

    PubMed Central

    Litwin, S. D.

    1970-01-01

    Antibodies directed against both human and infrahuman pepsin digested γ-globulin were present in a majority of the primate sera tested. The subhuman pepsin agglutinators paralleled previously described human pepsin agglutinators in respect to their wide distribution in normal sera, their specificity and cross-reactivity, and their immunochemical features. The pepsin agglutinators† at different primate levels appeared closely related. Among the subhuman pepsin agglutinators a subspecificity was described for a subhuman primate antigen. This finding suggested some limited differences between the subhuman pepsin agglutinators and the human pepsin agglutinators. Experimental immunization of four cynomologous monkeys failed to elicit or alter these serum reactants. PMID:4097824

  18. Agglutination of Mouse Erythrocytes by Eperythrozoon coccoides

    PubMed Central

    Iralu, Vichazelhu; Ganong, Kevin D.

    1983-01-01

    Erythrocytes from blood of mice infected with Eperythrozoon coccoides for 3 or 4 days agglutinated spontaneously. Washed E. coccoides particles agglutinated washed erythrocytes of uninfected mice. E. coccoides-mediated agglutination of normal mouse erythrocytes would be an excellent system for studies of bacterial adhesion. Images PMID:6832825

  19. Isolation and identification of Duck tembusu virus strain lH and development of latex-agglutination diagnostic method for rapid detection of antibodies.

    PubMed

    Wang, Quanxi; Wen, Yaping; Yifan Huang; Wu, Yijian; Cai, Yilong; Xu, Lihui; Wang, Changkang; Li, Ang; Wu, Baocheng; Chen, Jilong

    2014-12-01

    SUMMARY. An outbreak of egg-drop syndrome occurred on a Sheldrake duck farm in Longhai in Fujian Province, China, in 2012. The main clinical symptoms were sharply reduced egg production, crooked necks, and death. We isolated the virus from the sick ducks, identified it, and observed the histopathologic changes after viral infection. We detected viral RNA in the blood and feces of the infected ducks and developed a latex-agglutination diagnostic method to detect anti-Tembusu-virus antibodies. Our results show that the pathogenic virus is a Tembusu virus. The histopathologic changes included follicular cell degeneration and necrosis, follicular cavity filled with blood cells, massive necrosis in the brain, and degeneration and necrosis of the nerve and glial cells. When the transmission of the virus in the infected ducks was studied, the duck blood was positive for viral nucleic acid for up to 29 days, and the feces were positive for viral nucleic acid for up to 13 days. We successfully established a simple, rapid, and easy- to-use latex-agglutination diagnostic method for the detection of antibodies against duck Tembusu virus.

  20. THE INFLUENCE OF X-RAYS ON THE AGGLUTINATION REACTION IN ANIMALS VACCINATED AGAINST BRUCELLOSIS (in Russian)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhidovtsev, V.M.

    1961-08-01

    Tests on rabbits immunized with dry. live brucellosis vaccine and irradiated with 100, 200, and 400 r at the height of agglutination showed a drop in agglutin titer with increased x-ray dose. The higher the dose the faster is the drop n agglutin. (R.V.J.)

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dolmashkin, A A; Dubrovskii, V A; Zabenkov, I V

    The possibility is demonstrated to determine the human blood group by recording the scattering of laser radiation with the help of the digital imaging method. It is experimentally shown that the action of a standing ultrasound wave leads to acceleration of the agglutination reaction of red blood cells, to formation of larger immune complexes of red blood cells, and, as a consequence, to acceleration of their sedimentation. In the absence of agglutination of red blood cells the ultrasound does not enhance the relevant processes. This difference in the results of ultrasound action on the mixture of blood and serum allowsmore » a method of blood typing to be offered. Theoretical modelling of the technique of the practical blood typing, carried out on the basis of the elastic light scattering theory, agrees well with the experimental results, which made it possible to plan further improvement of the proposed method. The studies of specific features of sedimentation of red blood cells and their immune complexes were aimed at the optimisation of the sample preparation, i.e., at the search for such experimental conditions that provide the maximal resolution of the method and the device for registering the reaction of red blood cells agglutination. The results of the study may be used in designing the instrumentation for blood group assessment in humans.« less

  2. An Easy Method for Preparing Presentation Slides.

    ERIC Educational Resources Information Center

    Wright, Norman A.; Blevins, Dennis D.

    1984-01-01

    Describes a simplified method of preparing 35mm projection slides with a minimum of equipment and expertise. The quality of these slides compares favorably to professionally produced diazo slides. Twenty-five slides can easily be prepared in less than three hours. Material cost per slide is comparable to professional color slide processing. (JN)

  3. Blood group typing based on recording the elastic scattering of laser radiation using the method of digital imaging

    NASA Astrophysics Data System (ADS)

    Dolmashkin, A. A.; Dubrovskii, V. A.; Zabenkov, I. V.

    2012-05-01

    The possibility is demonstrated to determine the human blood group by recording the scattering of laser radiation with the help of the digital imaging method. It is experimentally shown that the action of a standing ultrasound wave leads to acceleration of the agglutination reaction of red blood cells, to formation of larger immune complexes of red blood cells, and, as a consequence, to acceleration of their sedimentation. In the absence of agglutination of red blood cells the ultrasound does not enhance the relevant processes. This difference in the results of ultrasound action on the mixture of blood and serum allows a method of blood typing to be offered. Theoretical modelling of the technique of the practical blood typing, carried out on the basis of the elastic light scattering theory, agrees well with the experimental results, which made it possible to plan further improvement of the proposed method. The studies of specific features of sedimentation of red blood cells and their immune complexes were aimed at the optimisation of the sample preparation, i.e., at the search for such experimental conditions that provide the maximal resolution of the method and the device for registering the reaction of red blood cells agglutination. The results of the study may be used in designing the instrumentation for blood group assessment in humans.

  4. Comparison of methods for the detection of coliphages in recreational water at two California, United States beaches.

    PubMed

    Rodríguez, Roberto A; Love, David C; Stewart, Jill R; Tajuba, Julianne; Knee, Jacqueline; Dickerson, Jerold W; Webster, Laura F; Sobsey, Mark D

    2012-04-01

    Methods for detection of two fecal indicator viruses, F+ and somatic coliphages, were evaluated for application to recreational marine water. Marine water samples were collected during the summer of 2007 in Southern California, United States from transects along Avalon Beach (n=186 samples) and Doheny Beach (n=101 samples). Coliphage detection methods included EPA method 1601 - two-step enrichment (ENR), EPA method 1602 - single agar layer (SAL), and variations of ENR. Variations included comparison of two incubation times (overnight and 5-h incubation) and two final detection steps (lysis zone assay and a rapid latex agglutination assay). A greater number of samples were positive for somatic and F+ coliphages by ENR than by SAL (p<0.01). The standard ENR with overnight incubation and detection by lysis zone assay was the most sensitive method for the detection of F+ and somatic coliphages from marine water, although the method takes up to three days to obtain results. A rapid 5-h enrichment version of ENR also performed well, with more positive samples than SAL, and could be performed in roughly 24h. Latex agglutination-based detection methods require the least amount of time to perform, although the sensitivity was less than lysis zone-based detection methods. Rapid culture-based enrichment of coliphages in marine water may be possible by further optimizing culture-based methods for saline water conditions to generate higher viral titers than currently available, as well as increasing the sensitivity of latex agglutination detection methods. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Red cell surface changes in cold agglutination

    PubMed Central

    Salsbury, A. J.; Clarke, J. A.; Shand, W. S.

    1968-01-01

    Surface changes in red blood cells undergoing cold agglutination have been investigated using the Cambridge Stereoscan electron microscope. On incubation of red cells with a cold agglutinin of anti-I specificity at 4°C, circular shadows on the red cell membrane developed within 2 min. At the same time the membrane showed a granularity and processes began to develop on the surface. These processes increased in length, the processes of contiguous cells became interlinked and agglutination was complete after incubation of 1 hr. On warming an agglutinated specimen, the process was reversed with separation of red cells and retraction of the finger-like processes to yield discrete red cells of normal appearance. The addition of heparin in vivo prevented agglutination but did not inhibit surface changes completely. Complement appeared to play no part in the production of cold agglutination due to these antibodies or in the reversal of agglutination by warming. The significance of the surface changes described in relation to previous information on the mechanism of agglutination, has been discussed. ImagesFig. 1Fig. 2Fig. 3Fig. 4Fig. 5Fig. 6Fig. 7Fig. 8Fig. 9Fig. 10Fig. 11 PMID:5655472

  6. Comparison of four DNA extraction methods for the detection of Mycobacterium leprae from Ziehl-Neelsen-stained microscopic slides.

    PubMed

    Ruiz-Fuentes, Jenny Laura; Díaz, Alexis; Entenza, Anayma Elena; Frión, Yahima; Suárez, Odelaisy; Torres, Pedro; de Armas, Yaxsier; Acosta, Lucrecia

    2015-12-01

    The diagnosis of leprosy has been a challenge due to the low sensibility of the conventional methods and the impossibility of culturing the causative organism. In this study, four methods for Mycobacterium leprae nucleic-acid extraction from Ziehl-Neelsen-stained slides (ZNS slides) were compared: Phenol/chloroform, Chelex 100 resin, and two commercial kits (Wizard Genomic DNA Purification Kit and QIAamp DNA Mini Kit). DNA was extracted from four groups of slides: a high-codification-slide group (bacteriological index [BI]⩾4), a low-codification-slide group (BI=1), a negative-slide group (BI=0), and a negative-control-slide group (BI=0). Quality DNA was evidenced by the amplification of specific repetitive element present in M. leprae genomic DNA (RLEP) using a nested polymerase chain reaction. This is the first report comparing four different extraction methods for obtaining M. leprae DNA from ZNS slides in Cuban patients, and applied in molecular diagnosis. Good-quality DNA and positive amplification were detected in the high-codification-slide group with the four methods, while from the low-codification-slide group only the QIAGEN and phenol-chloroform methods obtained amplification of M. leprae. In the negative-slide group, only the QIAGEN method was able to obtain DNA with sufficient quality for positive amplification of the RLEP region. No amplification was observed in the negative-control-slide group by any method. Patients with ZNS negative slides can still transmit the infection, and molecular methods can help identify and treat them, interrupting the chain of transmission and preventing the onset of disabilities. The ZNS slides can be sent easily to reference laboratories for later molecular analysis that can be useful not only to improve the diagnosis, but also for the application of other molecular techniques. Copyright © 2015 Asian-African Society for Mycobacteriology. Published by Elsevier Ltd. All rights reserved.

  7. Agglutinates as recorders of regolith evolution - Application to the Apollo 17 drill core

    NASA Technical Reports Server (NTRS)

    Laul, J. C.; Smith, M. R.; Papike, J. J.; Simon, S. B.

    1984-01-01

    Chemical data are reported for agglutinates from 26 depth intervals of the Apollo 17 deep drill core, and the compositions of the agglutinates are compared with those of the soils in which they occur. The agglutinate sequence suggests a scenario in which several closely-spaced depositional events were involved in the formation of the drill core, rather than a continuous accumulation process.

  8. Agglutinates as recorders of regolith evolution - Application to the Apollo 17 drill core

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laul, J.C.; Smith, M.R.

    1984-11-15

    Chemical data are reported for agglutinates from 26 depth intervals of the Apollo 17 deep drill core, and the compositions of the agglutinates are compared with those of the soils in which they occur. The agglutinate sequence suggests a scenario in which several closely-spaced depositional events were involved in the formation of the drill core, rather than a continuous accumulation process.

  9. Comparison of gel column, card, and cartridge techniques for dog erythrocyte antigen 1.1 blood typing

    PubMed Central

    Seth, Mayank; Jackson, Karen V.; Winzelberg, Sarah; Giger, Urs

    2012-01-01

    Objective To compare accuracy and ease of use of a card agglutination assay, an immunochromatographic cartridge method, and a gel-based method for canine blood typing. Sample Blood samples from 52 healthy blood donor dogs, 10 dogs with immune-mediated hemolytic anemia (IMHA), and 29 dogs with other diseases. Procedures Blood samples were tested in accordance with manufacturer guidelines. Samples with low PCVs were created by the addition of autologous plasma to separately assess the effects of anemia on test results. Results Compared with a composite reference standard of agreement between 2 methods, the gel-based method was found to be 100% accurate. The card agglutination assay was 89% to 91% accurate, depending on test interpretation, and the immunochromatographic cartridge method was 93% accurate but 100% specific. Errors were observed more frequently in samples from diseased dogs, particularly those with IMHA. In the presence of persistent autoagglutination, dog erythrocyte antigen (DEA) 1.1 typing was not possible, except with the immunochromatographic cartridge method. Conclusions and Clinical Relevance The card agglutination assay and immunochromatographic cartridge method, performed by trained personnel, were suitable for in-clinic emergency DEA 1.1 blood typing. There may be errors, particularly for samples from dogs with IMHA, and the immunochromatographic cartridge method may have an advantage of allowing typing of samples with persistent autoagglutination. The laboratory gel-based method would be preferred for routine DEA 1.1 typing of donors and patients if it is available and time permits. Current DEA 1.1 typing techniques appear to be appropriately standardized and easy to use. PMID:22280380

  10. Studies on a Factor in Sweet Potato Root Which Agglutinates Spores of Ceratocystis fimbriata, Black Rot Fungus 1

    PubMed Central

    Kojime, Mineo; Kawakita, Kazuhito; Uritani, Ikuzo

    1982-01-01

    A factor which agglutinated the spores of Ceratocystis fimbriata in the presence of Ca2+ was purified from sweet potato (Ipomea batatas Lam cv. Norin[1]) root. Element composition of the purified factor was as follows; analysis found: C (29.8%), H (3.97%), O (65.34%), N (0.81%): calculated for C43H69O70N1: C (30.02%), H (4.01%), O (65.15%), N (0.81%). The factor was mainly composed of galacturonic acid (53% of dry weight) and contained arabinose, fucose, and unidentified component as minor components. The factor also agglutinated A-, B-, AB-, and O types of human erythrocytes to almost the same degree in the presence of Ca2+. The differential spore-agglutinating activity of the factor depended on the pH of the assay medium; it agglutinated similarly the germinated spores of sweet potato and coffee strains at pH 7.5 and 5.5, whereas it displayed a distinct differential agglutinating activity at pH 6.5. The factor was assayed for spore-agglutinating activity at pH 6.5, using the germinated and ungerminated spores of seven strains of C. fimbriata; sweet potato, coffee, prune, cacao, oak, taro, and almond strains. The factor agglutinated ungerminated spores of all seven strains similarly, although small differences were observed among strains. On the other hand, a clear differential agglutination was observed among the germinated spores of various strains; sweet potato and almond strains were highly insensitive in comparison with other strains. The growth of the agglutinated spores of C. fimbriata was inhibited. These results are discussed in relation to host-parasite specificity. Images PMID:16662232

  11. Agglutination of intravenously administered phosphatidylcholine-containing lipid emulsions with serum C-reactive protein.

    PubMed

    Tugirimana, Pierrot; Speeckaert, Marijn M; Fiers, Tom; De Buyzere, Marc L; Kint, Jos; Benoit, Dominique; Delanghe, Joris R

    2013-04-01

    C-reactive protein (CRP) is able to bind phospholipids in the presence of calcium. We wanted to investigate the reaction of CRP with various commercial fat emulsions and to explore the impact of CRP agglutination on serum CRP levels. Serum specimens were mixed with Intralipid 20% (soybean oil-based fat emulsion), Structolipid (structured oil-based fat emulsion), Omegaven (fish oil-based fat emulsion), or SMOFlipid (mixed soybean oil-, olive oil-, and fish oil-based emulsion) in Tris-calcium buffer (pH 7.5). After 30 minutes of incubation at 37°C, CRP-phospholipid complexes were turbidimetrically quantified and flow cytometric analysis was performed. Similarly, CRP complexes were monitored in vivo, following administration of fat emulsion. CRP was able to agglutinate phospholipid-containing lipid droplets present in the soybean oil-based fat emulsion and the structured oil-based fat emulsion. To a lesser extent, agglutination was observed for fish oil-containing fat emulsions, whereas no agglutination was noticed for the mixed soybean oil-, olive oil-, and fish oil-based emulsion. Results for propofol-containing emulsions were comparable. Agglutination correlated with phospholipid content of the emulsions. When in vivo agglutination occurred, plasma CRP values dropped due to consumption of CRP by phospholipid-induced agglutination. In this in vitro experiment, we demonstrated agglutination of CRP with phospholipids in various fat emulsions. Research studies are required in patients to determine which effects occur with various intravenous fat emulsions.

  12. Rapid preparation of lecture slides.

    PubMed

    Persson, A V; Frusha, J D; Chevalier, R J

    1985-02-01

    When lecture slides must be prepared at a moment's notice, these methods of rapid preparation will allow you to create good quality slides. Although rush jobs are usually associated with higher costs, using these methods will keep the price per slide to a minimum. An investment must be made for the initial equipment, but the cost per slide is much less than that of slides produced by the standard methods. Type produced by typewriters or computer printers is adequate for most slides, but better slides can be produced with KroyType or Letraset letters. The KL film is preferred for reverse slides of text or line drawings, and the RPC film for production of radiographic slides. If an X-omat developer is not available, Polaroid film is a good alternative for rapid production of slides. The KL reverse slide projects best and can be colored, but RPC film produces a good positive slide of typed material. We have also photographed from a computer terminal screen using the KL film to make positive slides, the Polaroid continuous tone film for reverse slides, and Polaroid color film for color slides of material composed on a computer terminal with multicolor and graphics capabilities.

  13. Cross-reactions between alpha-streptococci and Omniserum, a polyvalent pneumococcal serum, demonstrated by direct immunofluorescence, immunoelectroosmophoresis, and latex agglutination.

    PubMed Central

    Holmberg, H; Danielsson, D; Hardie, J; Krook, A; Whiley, R

    1985-01-01

    In recent years several groups have used serological methods to demonstrate pneumococcal capsular antigens in sputum. In the present study 123 strains of alpha-hemolytic streptococci (including 97 strains from sputum or pharyngeal specimens) were tested for cross-reactions with a polyvalent antipneumococcal serum (Omniserum). Representatives of the following species were included: Streptococcus bovis, S. equinus, S. intermedius, S. lactis, S. milleri, S. mitis, S. mutans, S. sobrinus, S. salivarius, S. sanguis, S. suis, and Aerococcus viridans. Serological reactions were detected by direct immunofluorescence, immunoelectroosmophoresis, and latex agglutination. Fifteen (12%) of the strains gave positive reactions by all three methods. Positive reactions were also observed with another 32 strains (26%) with two of the methods, whereas 37 strains (30%) gave positive reactions by just one technique. Altogether 84 (68%) strains gave positive reactions with one or more of the methods. Latex agglutination gave positive reactions with 26 (21%) strains compared with 57 (46%) in immunofluorescence and 63 (51%) in immunoelectroosmophoresis. Absorption of the antiserum with one alpha-hemolytic strain reduced but did not entirely eliminate the cross-reactions with five tested strains. These findings indicate a potential risk of cross-reactions with polyvalent antipneumococcal serum in tests carried out on sputa or other specimens which may be contaminated with alpha-hemolytic streptococci. PMID:3889046

  14. Using slides to test for changes in crown defoliation assessment methods. Part I: Visual assessment of slides.

    PubMed

    Dobbertin, Matthias; Hug, Christian; Mizoue, Nobuya

    2004-11-01

    In this study we used photographs of tree crowns to test whether the assessment methods for tree defoliation in Switzerland have changed over time. We randomly selected 24 series of slides of Norway spruce with field assessments made between 1986 and 1995. The slides were randomly arranged and assessed by three experts without prior knowledge of the year when the slide was taken or the tree number. Defoliation was assessed using the Swiss reference photo guide. Although the correlations between the field assessments and slide assessments were high (Spearman's rank correlation coefficient ranged between 0.79 and 0.83), we found significant differences between field and slide assessments (4.3 to 9% underprediction by the slide assessors) and between the slide assessments. However, no significant trends in field assessment methods could be detected. When the mean differences between field and slide assessments were subtracted, in some years, field assessors consistently underpredicted (1990, 1992) or overpredicted defoliation (1987, 1991). Defoliation tended to be overpredicted in slides taken against the light, and underpredicted for trees with more than 25% crown overlap. We conclude that slide series can be used to detect changes in assessment methods. However, potential observer bias calls for more objective methods of assessment.

  15. New Model for Agglutinitic Glass Formation from LSCC Data

    NASA Technical Reports Server (NTRS)

    Pieters, C. M.; Taylor, L. A.

    2003-01-01

    Since the return of the first lunar samples it has been well known that glass-welded aggregates (agglutinates) accumulate in lunar soil as the result of multiple processes, many of which are driven by micrometeorite impacts. The proportion of agglutinates increases with increasing exposure to the space environment, and for an individual soil the proportion of agglutinates also increases with decreasing particle size. Detailed chemical and petrographic analyses of a suite of mare soils and their agglutinate constituents prepared by the Lunar Soil Characterization Consortium appeared to confirm the "Fusion of the Finest Fraction" model for agglutinate formation (or F3) proposed by Papike et al. However, recent LSCC data for highland soils are not consistent with the F3 model and alternate models for agglutinate formation must be revisited. Instead, we suggest differential melting of soil species may be more consistent with the full range of soil data to date.

  16. [Epidemiological profile and antibiotic resistance of Pseudomonas aeruginosa isolates in burn and traumatology center in Tunisia over a three-year period].

    PubMed

    Zoghlami, Ayoub; Kanzari, Lamia; Boukadida, Jalel; Messadi, Amen Allah; Ghanem, Abdelraouef

    2012-11-01

    Pseudomonas aeruginosa is a known opportunistic pathogen frequently causing serious infections in burned patients. To analyze the epidemiological profile of Pseudomonas aeruginosa isolated in a Tunisian burn unit. During a 3-year period (from 01 July 2008 to 30 June 2011), 544 non repetitive strains of P. aeruginosa were isolated from burn patients. Susceptibility to antibiotics was assessed according to CA-SFM guidelines. Serotypes were identified by slide agglutination test using P.aeruginosa O antisera (Biorad). Producing carbapenemase was analyzed for 202 imipenem resistant isolates by EDTA test. Susceptibility testing data were stored in a laboratory data base using whonet 5.3 software. The most frequent sites of isolation were cutaneous infections and blood cultures (83.4%). The percentages of resistant isolates were as follows: ceftazidime: 34%; imipenem: 37.1%, ciprofloxacin: 27.1% and amikacin: 29.6%. The most prevalent serotypes were: 011(51%), 06(17%), 03 (8%), 04(12%), 012(5%). Among the 202 imipenem resistant strains, 58% expressed a metallocarbapenemase. All theses strains were resistant to all tested antibiotics except colistin and belonged to the serotype O11. The dissemination of carbapenemases strains must be contained by implementation of timely identification, strict isolation methods and better hygienic procedures.

  17. Cryptococcus gattii in urban trees from cities in North-eastern Argentina.

    PubMed

    Mazza, Mariana; Refojo, Nicolás; Bosco-Borgeat, María Eugenia; Taverna, Constanza Giselle; Trovero, Alicia Cristina; Rogé, Ariel; Davel, Graciela

    2013-11-01

    In the city of Buenos Aires, Argentina, Cryptococcus gattii genotype AFLP4/VGI was found to be associated with decaying wood in hollows of different tree species. The aim of this study was to investigate the presence of C. gattii in the environment of riverside cities of the river Paraná, and to describe its serotypes and molecular types. Five hundred samples were collected in 50 parks by swabbing tree hollows. The samples were inoculated on caffeic acid agar supplemented with chloramphenicol, and incubated at 28 °C for 1 week with a daily observation. The isolates were identified by conventional methods. The serotype was determined by slide agglutination with specific antisera. Molecular typing was carried out by PCR-RFLP of the URA5 gene. Four isolates of C. gattii were recovered: Cryptococcus gattii serotype B, genotype AFLP4/VGI, isolated from Eucalyptus sp. in the city of Rosario and from Grevillea robusta in the city of La Paz; and C. gattii serotype C, genotype AFLP5/VGIII, isolated from two different Tipuana tipu trees in the city of Resistencia. Here, we report for the first time the isolation of C. gattii serotype C, genotype AFLP5/VGIII, from environmental samples in Argentina. © 2013 Blackwell Verlag GmbH.

  18. Real time observation and automated measurement of red blood cells agglutination inside a passive microfluidic biochip containing embedded reagents.

    PubMed

    Huet, Maxime; Cubizolles, Myriam; Buhot, Arnaud

    2017-07-15

    The process of agglutination is commonly used for the detection of biomarkers like proteins or viruses. The multiple bindings between micrometer sized particles, either latex beads or red blood cells (RBCs), create aggregates that are easily detectable and give qualitative information about the presence of the biomarkers. In most cases, the detection is made by simple naked-eye observation of agglutinates without any access to the kinetics of agglutination. In this study, we address the development of a real-time time observation of RBCs agglutination. Using ABO blood typing as a proof-of-concept, we developed i) an integrated biological protocol suitable for further use as point-of-care (POC) analysis and ii) two dedicated image processing algorithms for the real-time and quantitative measurement of agglutination. Anti-A or anti-B typing reagents were dried inside the microchannel of a passive microfluidic chip designed to enhance capillary flow. A blood drop deposit at the tip of the biochip established a simple biological protocol. In situ agglutination of autologous RBCs was achieved by means of embedded reagents and real time agglutination process was monitored by video recording. Using a training set of 24 experiments, two real-time indicators based on correlation and variance of gray levels were optimized and then further confirmed on a validation set. 100% correct discrimination between positive and negative agglutinations was performed within less than 2min by measuring real-time evolution of both correlation and variance indicators. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. [Serotype distribution and antimicrobial resistance of Salmonella isolates from retail chicken carcasses in six provinces of China].

    PubMed

    Hu, Y J; He, Y Y; Wang, Y R; Liu, C; Wang, M M; Gan, X; Wang, W; Yan, S F; Bai, Y; Peng, Z X; Li, F Q; Xu, J

    2018-04-06

    Objective: To obtain the serotype diversity and antimicrobial resistance of Salmonella isolates recovered from retail chicken carcasses for sale in six regions of China. Methods: From August 2010 to March 2012, each month 20 retail chicken carcasses including freshly slaughtered, chilled and frozen samples were collected from supermarkets and farmer's markets in 7 monitoring sites in Beijing, Jilin province, Inner Mongolia Autonomous, Shanxi province, Jiangsu province and Guangdong province, respectively. Samples were routinely collected for 12 months for each site. 1 680 chicken carcasses were collected in total and 2 629 Salmonella strains were isolated by PCR and biochemical method. Luminex xMAP method and classical slide agglutination method were carried out to determine isolates' serotypes. Minimal inhibitory concentrations (MICs) of 10 classes of antimicrobials including 14 agents were determined using broth micro-dilution method. Mocular methods were used to determine antimicrobial resistance genes of CIP-CTX-CT co-resistant isolates. Results: In all, 2 629 Salmonella isolates, there were 17 seorgroups and 58 serotypes, B and D1 were the dominant serogroups with rates of 34.7% ( n= 913) and 31.0% ( n= 815), Enteritidis (30.8%, n= 810), Indiana (17.6%, n= 463), Infantis (10.6%, n= 278) were the top three serovars. We found 224 CIP-CTX co-resistant S . Indiana containing 3 colistin resistant strains, one of them carrying mcr -1 gene and being ESBLs positive, which demonstrated a nine multi drug resistance against 11 antimicrobials tested. Conclusion: These data began to describe the complicated serovar diversity and heavy antimicrobial resistance of Salmonella isolates recovered from retail chicken carcasses in six regions of China. The findings highlight the emergence of ciprofloxacin and cefotaxime co-resistant S . Indiana and also a mcr -1 positive S . Indiana with heavy multi drug resistance.

  20. Typhoid fever in a Tertiary Hospital in Nigeria: Another look at the Widal agglutination test as a preferred option for diagnosis.

    PubMed

    Enabulele, Osahon; Awunor, Simeon Nyemike

    2016-01-01

    Single Widal agglutination test rather than blood culture, is commonly employed to diagnose typhoid fever in Nigeria. We took another look at the Widal agglutination test as a preferred option for diagnosis of typhoid fever by determining the specificity and sensitivity of Widal agglutination test in febrile adult patients. Two hundred and seventy-one blood samples from consecutive adults (>18 years) with febrile illness attending the General Practice Clinic of the University of Benin Teaching Hospital were tested using the Widal agglutination test, blood culture, and malaria parasite test on each sample to establish the diagnosis of typhoid fever. Of the 271 blood samples 124 (45.76%) were positive following a Widal agglutination test, 60 (22.10%) blood samples grew Salmonella organisms on blood culture while 55 (20.29%) blood samples showed a co-infection of typhoid fever and malaria. A sensitivity of 35%, specificity of 51%, positive predictive value of 17%, and a negative predictive value of 73% were observed for Widal agglutination test as a diagnostic modality for typhoid fever infection. A single Widal agglutination test is not a valid diagnostic option for typhoid fever while co-infection with malaria parasite is the preponderant microbiological finding in typhoid fever infections. The severity of malaria parasitemia is associated with positive titers on Widal test.

  1. Culturing and extraction of Coprococcus comes, absorption of serumagglutinins by soluble fractions and relation between agglutinins and antibodies in sera of patients with Crohn's disease.

    PubMed

    Hazenberg, M P; Pennock-Schröder, A M; van de Merwe, J P

    1986-01-01

    Agglutinating antibodies to Coprococcus comes and three other obligately anaerobic coccoid rods from the intestinal flora are used in the diagnosis of Crohn's disease. Further studies on the pathogenetic role as well as the development of more sensitive and specific methods for detecting antibodies require extraction of the antigen fractions. Culturing methods to obtain C. comes with optimal antigen presentation and isolation of soluble antigen fractions were therefore developed. Hot water extraction of whole cells and subsequent removal of proteins with trichloroacetic acid provided a fraction that absorbed serum agglutinins, was useful for an enzyme-linked immunosorbent assay and induced agglutinating antibodies in rats.

  2. Preventing Staphylococcus aureus sepsis through the inhibition of its agglutination in blood.

    PubMed

    McAdow, Molly; Kim, Hwan Keun; Dedent, Andrea C; Hendrickx, Antoni P A; Schneewind, Olaf; Missiakas, Dominique M

    2011-10-01

    Staphylococcus aureus infection is a frequent cause of sepsis in humans, a disease associated with high mortality and without specific intervention. When suspended in human or animal plasma, staphylococci are known to agglutinate, however the bacterial factors responsible for agglutination and their possible contribution to disease pathogenesis have not yet been revealed. Using a mouse model for S. aureus sepsis, we report here that staphylococcal agglutination in blood was associated with a lethal outcome of this disease. Three secreted products of staphylococci--coagulase (Coa), von Willebrand factor binding protein (vWbp) and clumping factor (ClfA)--were required for agglutination. Coa and vWbp activate prothrombin to cleave fibrinogen, whereas ClfA allowed staphylococci to associate with the resulting fibrin cables. All three virulence genes promoted the formation of thromboembolic lesions in heart tissues. S. aureus agglutination could be disrupted and the lethal outcome of sepsis could be prevented by combining dabigatran-etexilate treatment, which blocked Coa and vWbp activity, with antibodies specific for ClfA. Together these results suggest that the combined administration of direct thrombin inhibitors and ClfA-antibodies that block S. aureus agglutination with fibrin may be useful for the prevention of staphylococcal sepsis in humans.

  3. Direct agglutination test for serologic diagnosis of Neospora caninum infection.

    PubMed

    Romand, S; Thulliez, P; Dubey, J P

    1998-01-01

    A direct agglutination test was evaluated for the detection and quantitation of IgG antibodies to Neospora caninum in both experimental and natural infections in various animal species. As compared with results obtained by the indirect fluorescent antibody test, the direct agglutination test appeared reliable for the serologic diagnosis of neosporosis in a variety of animal species. The direct agglutination test should provide easily available and inexpensive tools for serologic testing for antibodies to N. caninum in many host species.

  4. Mutant botrocetin-2 inhibits von Willebrand factor-induced platelet agglutination.

    PubMed

    Matsui, T; Hori, A; Hamako, J; Matsushita, F; Ozeki, Y; Sakurai, Y; Hayakawa, M; Matsumoto, M; Fujimura, Y

    2017-03-01

    Essentials Botrocetin-2 (Bot2) binds to von Willebrand factor (VWF) and induces platelet agglutination. We identified Bot2 residues that are required for binding to VWF and glycoprotein (GP) Ib. We produced a mutant Bot2 that binds to VWF but inhibits platelet agglutination. Mutant Bot2 could be used as a potential anti-thrombotic reagent to block VWF-GPIb interaction. Background Botrocetin-2 (Bot2) is a botrocetin-like protein composed of α and β subunits that have been cloned from the snake Bothrops jararaca. Bot2 binds specifically to von Willebrand factor (VWF), and the complex induces glycoprotein (GP) Ib-dependent platelet agglutination. Objectives To exploit Bot2's VWF-binding capacity in order to attempt to create a mutant Bot2 that binds to VWF but inhibits platelet agglutination. Methods and Results Several point mutations were introduced into Bot2 cDNA, and the recombinant protein (recombinant Bot2 [rBot2]) was purified on an anti-botrocetin column. The mutant rBot2 with either Ala at Asp70 in the β subunit (Aspβ70Ala), or Argβ115Ala and Lysβ117Ala, showed reduced platelet agglutination-inducing activity. rBot2 with Aspβ70Ala showed little binding activity towards immobilized VWF on an ELISA plate, whereas rBot2 with Argβ115Ala/Lysβ117Ala showed reduced binding activity towards GPIb (glycocalicin) after forming a complex with VWF. rBot2 point-mutated to oppositely charged Glu at both Argβ115 and Lysβ117 showed normal binding activity towards VWF but no platelet-agglutinating activity. Furthermore, this doubly mutated protein inhibited ristocetin-induced or high shear stress-induced platelet aggregation, and restrained thrombus formation under flow conditions. Conclusions Asp70 in the β subunit of botrocetin is important for VWF binding, and Arg115 and Lys117 in the β subunit are essential for interaction with GPIb. Doubly mutated rBot2, with Argβ115Glu and Lysβ117Glu, repels GPIb and might have potential as an antithrombotic reagent that specifically blocks VWF function. This is the first report on an artificial botrocetin that can inhibit the VWF-GPIb interaction. © 2017 International Society on Thrombosis and Haemostasis.

  5. Galactosyltransferase and Concanavalin A Agglutination of Cells

    PubMed Central

    Podolsky, Daniel K.; Weiser, Milton M.; Mont, J. Thomas La; Isselbacher, Kurt J.

    1974-01-01

    A correlation has been observed between concanavalin A agglutination of various cell types and the presence of surface membrane galactosyltransferase (1-O-α-D-Galactosyl-myo-inositol:raffinose galactosyltransferase, EC 2.4.1.67) activity. Moreover, a reduction to less than 50% of cell surface galactosyltransferase activity occurred after treatment with concanavalin A; other cell surface glycosyltransferase enzyme activities examined were unaffected by concanavalin A treatment. To confirm the participation of cell surface galactosyltransferase in concanavalin A-induced cell agglutination, the enzyme from rabbit erythrocytes was solubilized by sonication and purified by preparative polyacrylamide gel electrophoresis. It was possible to achieve a purified preparation of rabbit erythrocyte galactosyltransferase by separation on concanavalin A-Sepharose. The purified enzyme showed visible immunoprecipitation (Ouchterlony) with concanavalin A. Furthermore, human erythrocytes, which are not normally agglutinated by concanavalin A, became agglutinable by the lectin when the erythrocytes were preincubated with purified galactosyltransferase. These experiments suggest a direct and possible specific role of cell surface galactosyltransferase enzyme in the mechanism of concanavalin A agglutination of cells. Images PMID:4522801

  6. Single agglutinates: A comparative study of compositions of agglutinitic glass, whole-grain, bulk soil, and FMR

    NASA Technical Reports Server (NTRS)

    Basu, A.; Robinson, R.; Mckay, D. S.; Blanchard, D. P.; Morris, R. V.; Wentworth, Susan J.

    1994-01-01

    Previous workers on single agglutinates have variously interpreted the composition of agglutinitic glass to represent impact melts of (1) bulk soil, (2) mixed components in finer sizes, and (3) microtargets. Separately, Papike has argued in favor of fusion of the finest fraction of bulk soils. Thirty-four single agglutinates were hand-picked from the mature Apollo 16 soil 61181 (I(sub s)/FeO = 82) and the FMR and chemical composition (INAA for Fe, Sc, Sm, Co, Ni, and Cr) of each agglutinate particle were measured. Thirteen of these single agglutinates were selected for electron beam microanalysis and imaging. Less than 1 micron spots were analyzed (for Na, Mg, Al, Si, P, S, K, Ca, Ti, Cr, Mn, Fe, Ni, and Ba) on pure glassy areas (approximately ten in each particle) selected on the basis of optical and BSE images (avoiding all clasts and inclusions) with an electron microprobe to obtain average glass compositions of each single agglutinate.

  7. An Alternative Chemical Redox Method for the Production of Bispecific Antibodies: Implication in Rapid Detection of Food Borne Pathogens

    PubMed Central

    Owais, Mohammad; Kazmi, Shadab; Tufail, Saba; Zubair, Swaleha

    2014-01-01

    Bi-functional antibodies with the ability to bind two unrelated epitopes have remarkable potential in diagnostic and bio-sensing applications. In the present study, bispecific antibodies that recognize human red blood cell (RBC) and the food borne pathogen Listeria monocytogenes (L. monocytogenes) were engineered. The procedure involves initial reduction of a mixture of anti-RBC and anti-Listeria antibodies followed by gradual re-oxidation of the reduced disulphides. This facilitates association of the separated antibody chains and formation of hybrid immunoglobulins with affinity for the L. monocytogenes and human RBC. The bispecific antibodies caused the agglutination of the RBCs only in the presence of L. monocytogenes cells. The agglutination process necessitated the specific presence of L. monocytogenes and the red colored clumps formed were readily visible with naked eyes. The RBC agglutination assay described here provides a remarkably simple approach for the rapid and highly specific screening of various pathogens in their biological niches. PMID:24637674

  8. Paper diagnostic for instantaneous blood typing.

    PubMed

    Khan, Mohidus Samad; Thouas, George; Shen, Wei; Whyte, Gordon; Garnier, Gil

    2010-05-15

    Agglutinated blood transports differently onto paper than stable blood with well dispersed red cells. This difference was investigated to develop instantaneous blood typing tests using specific antibody-antigen interactions to trigger blood agglutination. Two series of experiments were performed. The first related the level of agglutination and the fluidic properties of blood on its transport in paper. Blood samples were mixed at different ratios with specific and nonspecific antibodies; a droplet of each mixture was deposited onto a filter paper strip, and the kinetics of wicking and red cell separation were measured. Agglutinated blood phase separated, with the red blood cells (RBC) forming a distinct spot upon contact with paper while the plasma wicked; in contrast, stable blood suspensions wicked uniformly. The second study analyzed the wicking and the chromatographic separation of droplets of blood deposited onto paper strips pretreated with specific and nonspecific antibodies. Drastic differences in transport occurred. Blood agglutinated by interaction with one of its specific antibodies phase separated, causing a chromatographic separation. The red cells wicked very little while the plasma wicked at a faster rate than the original blood sample. Blood agglutination and wicking in paper followed the concepts of colloids chemistry. The immunoglobin M antibodies agglutinated the red blood cells by polymer bridging, upon selective adsorption on the specific antigen at their surface. The transport kinetics was viscosity controlled, with the viscosity of red cells drastically increasing upon blood agglutination. Three arm prototypes were investigated for single-step blood typing.

  9. Agglutination of human erythrocytes by the interaction of Zn(2+)ion with histidine-651 on the extracellular domain of band 3.

    PubMed

    Kiyotake, Kento; Ochiai, Hideharu; Yamaguchi, Takeo

    2016-05-01

    Clustering of band 3, chloride/bicarbonate exchanger, has been reported in Zn(2+)-treated human erythrocytes. However, the agglutination of human erythrocytes is also induced by the interaction of Zn(2+)ion with histidine on band 3. Identification of histidine that interacts with Zn(2+)ion remains to be determined. The Zn(2+)-induced agglutination of human erythrocytes was unaffected by chymotrypsin cleavage of the small loop region containing His-547 in the extracellular domain of band 3. On the other hand, papain digestion of the large loop region containing His-651 in band 3 inhibited such Zn(2+)-induced agglutination. Moreover, Zn(2+)-induced erythrocyte agglutination was inhibited by the peptide (ARGWVIHPLG) containing His-651, but not by the peptide such as ARGWVIRPLG, which His-651 was substituted by arginine. Among 10 kinds of animal erythrocytes tested, interestingly, no agglutination by Zn(2+)ions was observed in cow cells only that the forth amino acid in the upstream from His-669 on the large loop of cow band 3 is aspartate (Asp-665) instead of glycine. As expected, the agglutination of human erythrocytes by Zn(2+) ions was inhibited in the presence of aspartate. These data indicate that the interaction of Zn(2+) ion with His-651 residue of band 3 plays an important role in the Zn(2+)-induced agglutination of human erythrocytes. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. A method for reducing the sloughing of thick blood films for malaria diagnosis.

    PubMed

    Norgan, Andrew P; Arguello, Heather E; Sloan, Lynne M; Fernholz, Emily C; Pritt, Bobbi S

    2013-07-08

    The gold standard for malaria diagnosis is the examination of thick and thin blood films. Thick films contain 10 to 20 times more blood than thin films, correspondingly providing increased sensitivity for malaria screening. A potential complication of thick film preparations is sloughing of the blood droplet from the slide during staining or rinsing, resulting in the loss of sample. In this work, two methods for improving thick film slide adherence ('scratch' (SCM) and 'acetone dip' (ADM) methods) were compared to the 'standard method' (SM) of thick film preparation. Standardized blood droplets from 26 previously examined EDTA whole blood specimens (22 positive and four negative) were concurrently spread on glass slides using the SM, ADM, and SCM. For the SM and ADM prepared slides, the droplet was gently spread to an approximate 22 millimeters in diameter spot on the slide using the edge of a second glass slide. For the SCM, the droplet was spread by carefully grinding (or scratching) it into the slide with the point of a second glass slide. Slides were dried for one hour in a laminar flow hood. For the ADM, slides were dipped once in an acetone filled Coplin jar and allowed to air dry. All slides were then Giemsa-stained and examined in a blinded manner. Adherence was assessed by blinded reviewers. No significant or severe defects were observed for slides prepared with the SCM. In contrast, 8 slides prepared by the ADM and 3 prepared using the SM displayed significant or severe defects. Thick films prepared by the three methods were microscopically indistinguishable and concordant results (positive or negative) were obtained for the three methods. Estimated parasitaemia of the blood samples ranged from 25 to 429,169 parasites/μL of blood. The SCM is an inexpensive, rapid, and simple method that improves the adherence of thick blood films to standard glass slides without altering general slide preparation, microscopic appearance or interpretability. Using the SCM, thick films can be reliably examined less than two hours after sample receipt. This represents a significant diagnostic improvement over protocols requiring extended drying periods.

  11. Efficacy of a chairside diagnostic test kit for estimation of C-reactive protein levels in periodontal disease

    PubMed Central

    Nagarale, Girish; Ravindra, S.; Thakur, Srinath; Setty, Swati

    2010-01-01

    Background: C-reactive protein [CRP] levels increase to hundreds of mg/mL within hours following infection. Studies have shown that serum CRP levels were elevated in periodontal disease. However, in all the previous studies, CRP levels were measured by using high-sensitivity CRP assay kits with minimal detection limits of 0.1 to 3 mg/L, which was much below the normal value of 10 mg/L. These high-sensitivity CRP assays need a proper laboratory setup, and these methods cannot be used as a routine chair-side test in the dental office. Aim: The purpose of this study was to investigate the serum CRP levels in subjects with periodontal disease by using a rapid chair-side diagnostic test kit with a lower detection limit of 6 mg/L and to compare the CRP levels before and after periodontal therapy. Materials and Methods: A total of 45 systemically healthy subjects were selected for the study. Subjects were divided into three groups: group A: healthy controls, group B: gingivitis, group C: periodontitis. Serum levels of CRP were determined by using a latex slide agglutination method with commercially available kit with lower detection limit of 6 mg/L. Results: CRP was negative in all the 15 subjects in groups A and B at baseline, 7th and 30th day. CRP was positive only in 2 subjects in Group C at baseline and 7th day. Conclusion: Estimation of serum CRP by using a rapid chair-side diagnostic test kit is not of any significance in subjects with periodontitis. PMID:21731244

  12. A novel paper-based assay for the simultaneous determination of Rh typing and forward and reverse ABO blood groups.

    PubMed

    Noiphung, Julaluk; Talalak, Kwanrutai; Hongwarittorrn, Irin; Pupinyo, Naricha; Thirabowonkitphithan, Pannawich; Laiwattanapaisal, Wanida

    2015-05-15

    We propose a new, paper-based analytical device (PAD) for blood typing that allows for the simultaneous determination of ABO and Rh blood groups on the same device. The device was successfully fabricated by using a combination of wax printing and wax dipping methods. A 1:2 blood dilution was used for forward grouping, whereas whole blood could be used for reverse grouping. A 30% cell suspension of A-cells or B-cells was used for haemagglutination on the reverse grouping side. The total assay time was 10 min. The ratio between the distance of red blood cell movement and plasma separation is the criterion for agglutination and indicates the presence of the corresponding antigen or antibody. The proposed PAD has excellent reproducibility in that the same blood groups, namely A, AB, and O, were reported by using different PADs that were fabricated on the same day (n=10). The accuracy for detecting blood group A (n=12), B (n=13), AB (n=9), O (n=14), and Rh (n=48) typing were 92%, 85%, 89%, 93%, and 96%, respectively, in comparison with the conventional slide test method. The haematocrit of the sample affects the accuracy of the results, and appropriate dilution is suggested before typing. In conclusion, this study proposes a novel method that is straightforward, time-saving, and inexpensive for the simultaneous determination of ABO and Rh blood groups, which is promising for use in developing countries. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Agglutination reactions of human leucocytes

    PubMed Central

    Schulz, Jeanette; Muller, Helga

    1963-01-01

    Agglutination tests with various sera and leucocytes from 58 leukaemic patients and 61 patients without leukaemia are reported. The agglutination of white blood cells by guinea-pig serum is of limited value in the diagnosis of leukaemia, though the test may be helpful in distinguishing leukaemia from other lymphomatous disorders. Leuco-autoagglutinins were demonstrated more frequently than expected. Eleven leukaemic and six non-leukaemic sera agglutinated autologous leucocytes. White blood cell agglutinins showed no apparent relationship to maturity or numbers of circulating leucocytes or to previous blood transfusions, x-irradiation, or therapy with antimetabolites. PMID:14044034

  14. Preventing Staphylococcus aureus Sepsis through the Inhibition of Its Agglutination in Blood

    PubMed Central

    McAdow, Molly; Kim, Hwan Keun; DeDent, Andrea C.; Hendrickx, Antoni P. A.; Schneewind, Olaf; Missiakas, Dominique M.

    2011-01-01

    Staphylococcus aureus infection is a frequent cause of sepsis in humans, a disease associated with high mortality and without specific intervention. When suspended in human or animal plasma, staphylococci are known to agglutinate, however the bacterial factors responsible for agglutination and their possible contribution to disease pathogenesis have not yet been revealed. Using a mouse model for S. aureus sepsis, we report here that staphylococcal agglutination in blood was associated with a lethal outcome of this disease. Three secreted products of staphylococci - coagulase (Coa), von Willebrand factor binding protein (vWbp) and clumping factor (ClfA) – were required for agglutination. Coa and vWbp activate prothrombin to cleave fibrinogen, whereas ClfA allowed staphylococci to associate with the resulting fibrin cables. All three virulence genes promoted the formation of thromboembolic lesions in heart tissues. S. aureus agglutination could be disrupted and the lethal outcome of sepsis could be prevented by combining dabigatran-etexilate treatment, which blocked Coa and vWbp activity, with antibodies specific for ClfA. Together these results suggest that the combined administration of direct thrombin inhibitors and ClfA-antibodies that block S. aureus agglutination with fibrin may be useful for the prevention of staphylococcal sepsis in humans. PMID:22028651

  15. Agglutination by anti-capsular polysaccharide antibody is associated with protection against experimental human pneumococcal carriage

    PubMed Central

    Reiné, J; Zangari, T; Owugha, JT; Pennington, SH; Gritzfeld, JF; Wright, AD; Collins, AM; van Selm, S; de Jonge, MI; Gordon, SB; Weiser, JN; Ferreira, DM

    2016-01-01

    The ability of pneumococcal conjugate vaccine (PCV) to decrease transmission by blocking the acquisition of colonization has been attributed to herd immunity. We describe the role of mucosal IgG to capsular polysaccharide (CPS) in mediating protection from carriage, translating our findings from a murine model to humans. We used a flow-cytometric assay to quantify antibody-mediated agglutination demonstrating that hyperimmune sera generated against an unencapsulated mutant was poorly agglutinating. Passive immunization with this antiserum was ineffective to block acquisition of colonization compared to agglutinating antisera raised against the encapsulated parent strain. In the human challenge model samples were collected from PCV and control vaccinated adults. In PCV-vaccinated subjects IgG levels to CPS were increased in serum and nasal wash (NW). IgG to the inoculated strain CPS dropped in NW samples after inoculation suggesting its sequestration by colonizing pneumococci. In post-vaccination NW samples pneumococci were heavily agglutinated compared to pre-vaccination samples in subjects protected against carriage. Our results indicate that pneumococcal agglutination mediated by CPS specific antibodies is a key mechanism of protection against acquisition of carriage. Capsule may be the only vaccine target that can elicit strong agglutinating antibody responses, leading to protection against carriage acquisition and generation of herd immunity. PMID:27579859

  16. [Response of Calliphora vicina larval hemocytes to abiotic and biotic foreign particles injection].

    PubMed

    Kind, T V

    2012-01-01

    Human erythrocytes injection into the body cavity of Calliphora vicina postfeeding larvae results to their fast binding by thrombocytoidal fragments with agglutinates formation. There were almost none sites of lysis and degradation of erythrocytes in agglutinates even after shape modification and strands generation. Exceptions are zones of agglutinates with juvenile hemocytes, where destruction of erythrocytes is seen. The sequential injection of erythrocytes and charcoal particles leads to charcoal adhesion at first to agglutinates periphery and later to more deep stratum of cytoplasm between the erythrocytes. Under such conditions agglutinate formation period is accompanied with morphology variations which do not influence the intensity of agglutinating reaction. Juvenile plasmatocytes phagocytized the charcoal particles regardless of their concentration and duration of previous contact with erythrocytes. When mixture of abiotic and biotic particles was injected into post feeding larvae, crythrocytes and charcoal generate independent aggregations in the range of separate agglutinates. At the same time plasmatocytes form nodules consisting of temporary cell aggregations covered with cores of non phagocytized charcoal particles. These data testified that presumably lectin receptors responsible for foreign biotic and abiotic particles recognition are very near but not identical for different types of hemocytes. They may be specifical (for plasmatocytes) or integrated to different parts of cellular membrane (in thrombocytoids).

  17. Immunoassay control method based on light scattering

    NASA Astrophysics Data System (ADS)

    Bilyi, Olexander I.; Kiselyov, Eugene M.; Petrina, R. O.; Ferensovich, Yaroslav P.; Yaremyk, Roman Y.

    1999-11-01

    The physics principle of registration immune reaction by light scattering methods is concerned. The operation of laser nephelometry for measuring antigen-antibody reaction is described. The technique of obtaining diagnostic and immune reactions of interaction latex agglutination for diphtheria determination is described.

  18. Evaluation of agglutination strength by a flow-induced cell movement assay based surface plasmon resonance (SPR) technique.

    PubMed

    Sudprasert, Krisda; Peungthum, Patjaree; Vongsakulyanon, Apirom; Amarit, Ratthasart; Somboonkaew, Armote; Sutapun, Boonsong; Kitpoka, Pimpun; Kunakorn, Mongkol; Srikhirin, Toemsak

    2015-02-07

    A flow-induced cell movement assay combined with a surface plasmon resonance (SPR) technique was developed to quantify the agglutination strength, derived from the standard tube-agglutination test. Red blood cells (RBCs), based on the ABO blood group system, were specifically captured by anti-A and/or anti-B antibodies immobilized on a sensor surface. The agglutination strength corresponds to the amount of antigen-antibody interactions or the strength of RBC adhesion. Under a shear flow, the adherent RBCs were forced to move out of the region of interest with different average cell velocities (vc) depending upon the adhesion strength and wall shear stress (WSS). That is, a higher adhesion strength (higher agglutination strength) or lower WSS represents a lower vc or vice versa. In this work, the agglutination strength was derived from the vc that was calculated from the time derivative of the relative SPR signal by using a simple model of cell movement response, whose validity was verified. The vc values of different samples were correlated with their agglutination strengths at a given WSS and antibody surface density. The vc decreased as the agglutination strength increased, which can be considered as a linear regression. The coefficient of variation of the calculated vc decreased to 0.1 as vc increased to 30 μm min(-1). The sensitivity of this assay can be controlled by optimizing the antibody surface density or the WSS. This assay has the capability to resolve the antigen density of A1 and B RBCs from that of A1B RBCs.

  19. A comparative study of Widal test with blood culture in the diagnosis of typhoid fever in febrile patients.

    PubMed

    Andualem, Gizachew; Abebe, Tamrat; Kebede, Nigatu; Gebre-Selassie, Solomon; Mihret, Adane; Alemayehu, Haile

    2014-09-17

    Typhoid fever is a major health problem in developing countries and its diagnosis on clinical ground is difficult. Diagnosis in developing countries including Ethiopia is mostly done by Widal test. However, the value of the test has been debated. Hence, evaluating the result of this test is necessary for correct interpretation of the result. The main aim of this study was to compare the result of Widal test and blood culture in the diagnosis of typhoid fever in febrile patients. Blood samples were collected from 270 febrile patients with symptoms clinically similar to typhoid fever and visiting St. Paul's General Specialized Hospitals from mid December 2010 to March 2011. Blood culture was used to isolate S.typhi and S.paratyphi. Slide agglutination test and tube agglutination tests were used for the determination of antibody titer. An antibody titer of ≥1:80 for anti TO and ≥1:160 for anti TH were taken as a cut of value to indicate recent infection of typhoid fever. One hundred and eighty six (68.9%) participants were females and eighty four (31.1%) were males. 7 (2.6%) cases of S. typhi and 4 (1.5%) cases of S. paratyphi were identified with the total prevalence of typhoid fever 4.1%. The total number of patients who have indicative of recent infection by either of O and H antigens Widal test is 88 (32.6%). The sensitivity, specificity, Positive predictive Value and Negative predictive Value of Widal test were 71.4%, 68.44%, 5.7% and 98.9% respectively. Widal test has a low sensitivity, specificity and PPV, but it has good NPV which indicates that negative Widal test result have a good indication for the absence of the disease.

  20. Sero-epidemiological survey and risk factors associated with brucellosis in dogs in south-western Nigeria.

    PubMed

    Ayoola, Modupe Comfort; Ogugua, Akwoba Joseph; Akinseye, Victor Oluwatoyin; Joshua, Tunde Olu; Banuso, Morenikeji Folusho; Adedoyin, Folashade Julianah; Adesokan, Hezekiah Kehinde; Omobowale, Temidayo Olutayo; Abiola, John Olusoji; Otuh, Patricia Ihuaku; Nottidge, Helen Oyebukola; Dale, Emma-Jane; Perrett, Lorraine; Taylor, Andrew; Stack, Judy; Cadmus, Simeon Idowu Babalola

    2016-01-01

    In Nigeria, there is limited information on brucellosis particularly in dogs, despite its public health implications. We undertook a sero-epidemiological survey of brucellosis in dogs to determine the prevalence of the disease and associated risk factors for its occurrence in Nigeria. A cross-sectional study was conducted to screen dogs in south-western Nigeria for antibodies to Brucella sp using the rapid slide agglutination test (RSA) and Rose Bengal test (RBT), with positive samples confirmed respectively by serum agglutination test (SAT) and competitive enzyme linked immunosorbent assay (cELISA). Data were analyzed with STATA-12. From the 739 dog sera tested, 81 (10.96%) were positive by RSA and 94 (12.72%) by RBT; these were corroborated with SAT (4/81; 4.94%) and cELISA (1/94; 1.06%), respectively. Logistic regression identified location (OR=0.04; 95% CI: 0.02-0.09), breed (OR=1.71; 95% CI: 1.34-2.19), age (OR=0.10; 95% CI: 0.04-0.30) and management system (OR=8.51; 95% CI: 1.07-68.05) as risk factors for Brucella infection by RSA. However, location (OR=10.83; 95% CI: 5.48-21.39) and history of infertility (OR=2.62; 95% CI: 1.41-4.84) were identified as risk factors using RBT. Given the 10.96% to 12.72% seroprevalence of brucellosis recorded in this study, we advocate control of the disease in dogs, and public health education for those at risk of infection. Again, further studies are required to elucidate the role of dogs in the epidemiology of brucellosis in Nigeria considering the conducive human-animal interface and ecological factors responsible for the transmission of the disease.

  1. Signature-tagged mutagenesis screening revealed a novel smooth-to-rough transition determinant of Salmonella enterica serovar Enteritidis.

    PubMed

    Jiao, Yang; Guo, Rongxian; Tang, Peipei; Kang, Xilong; Yin, Junlei; Wu, Kaiyue; Geng, Shizhong; Li, Qiuchun; Sun, Jun; Xu, Xiulong; Zhou, Xiaohui; Gan, Junji; Jiao, Xinan; Liu, Xiufan; Pan, Zhiming

    2017-03-03

    Salmonella enterica serovar Enteritidis (S. Enteritidis) has emerged as one of the most important food-borne pathogens for humans. Lipopolysaccharide (LPS), as a component of the outer membrane, is responsible for the virulence and smooth-to-rough transition in S. Enteritidis. In this study, we screened S. Enteritidis signature-tagged transposon mutant library using monoclonal antibody against somatic O 9 antigen (O 9 MAb) and O 9 factor rabbit antiserum to identify novel genes that are involved in smooth-to-rough transition. A total of 480 mutants were screened and one mutant with transposon insertion in rfbG gene had smooth-to-rough transition phenotype. In order to verify the role of rfbG gene, an rfbG insertion or deletion mutant was constructed using λ-Red recombination system. Phenotypic and biological analysis revealed that rfbG insertion or deletion mutants were similar to the wild-type strain in growth rate and biochemical properties, but the swimming motility was reduced. SE Slide Agglutination test and ELISA test showed that rfbG mutants do not stimulate animals to produce agglutinating antibody. In addition, the half-lethal dose (LD 50 ) of the rfbG deletion mutant strain was 10 6.6 -fold higher than that of the parent strain in a mouse model when injected intraperitoneally. These data indicate that the rfbG gene is involved in smooth-to-rough transition, swimming motility and virulence of S. Enteritidis. Furthermore, somatic O-antigen antibody-based approach to screen signature-tagged transposon mutants is feasible to clarify LPS biosynthesis and to find suitable markers in DIVA-vaccine research.

  2. 9 CFR 147.1 - The standard tube agglutination test. 1

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false The standard tube agglutination test. 1 147.1 Section 147.1 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... Blood Testing Procedures § 147.1 The standard tube agglutination test. 1 1 The procedure described is a...

  3. 9 CFR 147.1 - The standard tube agglutination test. 1

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false The standard tube agglutination test. 1 147.1 Section 147.1 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... Blood Testing Procedures § 147.1 The standard tube agglutination test. 1 1 The procedure described is a...

  4. 9 CFR 147.1 - The standard tube agglutination test. 1

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false The standard tube agglutination test. 1 147.1 Section 147.1 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... Blood Testing Procedures § 147.1 The standard tube agglutination test. 1 1 The procedure described is a...

  5. 9 CFR 147.1 - The standard tube agglutination test. 1

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false The standard tube agglutination test. 1 147.1 Section 147.1 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... Blood Testing Procedures § 147.1 The standard tube agglutination test. 1 1 The procedure described is a...

  6. 9 CFR 147.1 - The standard tube agglutination test. 1

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false The standard tube agglutination test. 1 147.1 Section 147.1 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... Blood Testing Procedures § 147.1 The standard tube agglutination test. 1 1 The procedure described is a...

  7. Dodecamer is required for agglutination of Litopenaeus vannamei hemocyanin with bacterial cells and red blood cells.

    PubMed

    Pan, Jian-yi; Zhang, Yue-ling; Wang, San-ying; Peng, Xuan-xian

    2008-01-01

    Hemocyanins are multi-functional proteins, although they are well known to be respiratory proteins of invertebrate to date. In the present study, the agglutination ability of two oligomers of hemocyanin, hexamer and dodecamer, with pathogenic bacteria and red blood cells (RBCs) is investigated in pacific white shrimp, Litopenaeus vannamei. Hexameric hemocyanin exhibits an extremely high stability even in the absence of Ca(2+) and in alkaline pH. Dodecamer (di-hexamer) is easily dissociated into hexamers in unphysiological conditions. Hexamer and dodecamer are interchanged reciprocally with environmental conditions. Both oligomers can bind to bacteria and RBCs, but agglutination is observed only using dodecamer but not using hexamer in agglutination assay. However, the agglutination is detected when hexamer is utilized in the presence of antiserum against hemocyanin. These results indicate that dodecamer of hemocyanin is required for agglutination with bacteria and RBCs. It can be logically inferred that there is only one carbohydrate-binding site to bacterial cells and RBCs in the hexamer, while at least two sites in the dodecamer. Our finding has provided new insights into structural-functional relationship of hemocyanin.

  8. Anejaculation following spinal cord injury does not induce sperm-agglutinating antibodies.

    PubMed

    Dahlberg, A; Hovatta, O

    1989-02-01

    Antisperm antibodies were tested for by the MAR-test and the tray agglutination test in 16 men with spinal cord injury. None of these men could ejaculate without artificial methods. Seven men ejaculated externally by vibrator stimulation or electroejaculation, while seven exhibited retrograde ejaculation; in two cases no semen was obtained. Sperm density in the external ejaculations was high (average = 405 x 10(6)/ml), with 10-45% motility. None of these 16 men had antisperm antibodies. This result indicates that anejaculation and sperm retention in men with spinal cord injury, even of 30 years duration, does not result in antisperm antibody formation.

  9. Morphological, Cultural, Biochemical, and Serological Comparison of Japanese Strains of Vibrio parahemolyticus with Related Cultures Isolated in the United States

    PubMed Central

    Twedt, Robert M.; Spaulding, Procter L.; Hall, Herbert E.

    1969-01-01

    Morphological, cultural, biochemical, and serological characteristics of 79 strains of Vibrio parahemolyticus isolated from patients suffering from gastroenteric disease in Japan were compared with 17 suspected V. parahemolyticus cultures isolated from wound infections and 14 nonpathogenic vibrios isolated from an estuarine environment in the United States. These groups were differentiated on the basis of several key reactions which included: the range of growth temperature and salt tolerance; the production of catalase and acetoin; the hydrolysis of starch; the fermentation and utilization as single carbon source of sucrose, cellobiose, and arabinose; and the ability to swarm on 1% agar. The separation of the groups on the basis of cultural and biochemical analyses was confirmed by means of slide agglutinations with specific anti-K antisera. The results of this study strongly suggest that the wound infection isolates are V. parahemolyticus species which are easily distinguished from the nonpathogenic estuarine vibrios. PMID:5784207

  10. Morphological, cultural, biochemical, and serological comparison of Japanese strains of Vibrio parahemolyticus with related cultures isolated in the United States.

    PubMed

    Twedt, R M; Spaulding, P L; Hall, H E

    1969-05-01

    Morphological, cultural, biochemical, and serological characteristics of 79 strains of Vibrio parahemolyticus isolated from patients suffering from gastroenteric disease in Japan were compared with 17 suspected V. parahemolyticus cultures isolated from wound infections and 14 nonpathogenic vibrios isolated from an estuarine environment in the United States. These groups were differentiated on the basis of several key reactions which included: the range of growth temperature and salt tolerance; the production of catalase and acetoin; the hydrolysis of starch; the fermentation and utilization as single carbon source of sucrose, cellobiose, and arabinose; and the ability to swarm on 1% agar. The separation of the groups on the basis of cultural and biochemical analyses was confirmed by means of slide agglutinations with specific anti-K antisera. The results of this study strongly suggest that the wound infection isolates are V. parahemolyticus species which are easily distinguished from the nonpathogenic estuarine vibrios.

  11. Results of a 6-month survey of stool cultures for Escherichia coli O157:H7.

    PubMed

    Marshall, W F; McLimans, C A; Yu, P K; Allerberger, F J; Van Scoy, R E; Anhalt, J P

    1990-06-01

    Escherichia coli O157:H7 is a recently recognized enteric pathogen that causes acute hemorrhagic colitis. Although the infection is usually self-limited, it may be complicated by hemolytic uremic syndrome and thrombotic thrombocytopenic purpura. At our institution, stool specimens are now routinely cultured for this organism. To determine the prevalence of E. coli O157:H7-associated diarrhea in our patient population, we surveyed all submitted stool cultures for 6 months for this organism. Specimens were screened for non-sorbitol fermenting E. coli and confirmed by slide-agglutination and immobilization testing. Of 2,164 specimens, 10 yielded E. coli O157:H7. It was the fourth most common bacterial stool pathogen found. Bloody diarrhea and abdominal pain were the most common symptoms of the infected patients. E. coli O157:H7 causes sporadic infections in our patient population and should be considered in the differential diagnosis of acute hemorrhagic colitis.

  12. Differential actions of proteinases and neuraminidase on mammalian erythrocyte surface and its impact on erythrocyte agglutination by concanavalin A.

    PubMed

    Sharma, Savita; Gokhale, Sadashiv M

    2012-12-01

    Action of proteinases viz. trypsin and chymotrypsin, and neuraminidase on intact erythrocyte membrane proteins and glycophorins (sialoglycoproteins) exposed to cell surface and its impact on lectin (concanavalin A)-mediated agglutination were studied in Homo sapiens (human), Capra aegagrus hircus (goat) and Bubalus bubalis (buffalo). Membrane proteins and glycophorins analysis by SDS-PAGE as visualized by coomassie brilliant blue and periodic acid-schiff stains, respectively, and agglutination behaviour revealed marked differences: 1) there were prominent dissimilarities in the number and molecular weights of glycophorins in human, goat and buffalo erythrocyte membranes; 2) proteinase action(s) on human and buffalo erythrocyte surface membrane proteins and glycophorins showed similarity but was found different in goat; 3) significant differences in erythrocyte agglutinability with concanavalin A can be attributed to differences in membrane composition and alterations in the surface proteins after enzyme treatment; 4) a direct correlation was found between degradation of glycophorins and concanavalin A agglutinability; 5) action of neuraminidase specifically indicated the negative role of cell surface sialic acids in determining concanavalin A agglutinability of goat and buffalo erythrocytes, similar to human. Present studies clearly indicate that there are some basic differences in human, goat and buffalo erythrocyte membrane proteins, especially with respect to glycophorins, which determine the concanavalin A-mediated agglutination in enzyme treated erythrocytes.

  13. Antibody blocks acquisition of bacterial colonization through agglutination

    PubMed Central

    Roche, A. M.; Richard, A. L.; Rahkola, J. T.; Janoff, E. N.; Weiser, J. N.

    2014-01-01

    Invasive infection often begins with asymptomatic colonization of mucosal surfaces. A murine model of bacterial colonization with Streptococcus pneumoniae was used to study the mechanism for mucosal protection by immunoglobulin. In previously colonized immune mice, bacteria were rapidly sequestered within large aggregates in the nasal lumen. To further examine the role of bacterial agglutination in protection by specific antibodies, mice were passively immunized with IgG purified from anti-pneumococcal sera or pneumococcal type-specific monoclonal human IgA (hIgA1 or hIgA2). Systemically-delivered IgG accessed the mucosal surface and blocked acquisition of colonization and transmission between littermates. Optimal protection by IgG was independent of Fc fragment and complement and, therefore, did not involve an opsonophagocytic mechanism. Enzymatic digestion or reduction of IgG prior to administration showed that protection required divalent binding that maintained its agglutinating effect. Divalent hIgA1 is cleaved by the pneumococcal member of a family of bacterial proteases that generate monovalent Fabα fragments. Thus, passive immunization with hIgA1 blocked colonization by an IgA1-protease deficient mutant (agglutinated), but not the protease-producing wild-type parent (not agglutinated), whereas protease-resistant hIgA2 agglutinated and blocked colonization by both. Our findings highlight the importance of agglutinating antibodies in mucosal defense and reveal how successful pathogens evade this effect. PMID:24962092

  14. [Differentiation of nonspecific serological reactions in brucellosis].

    PubMed

    Khristoforov, L

    1979-01-01

    Differentiation of non-specific agglutination was performed by the complement binding reaction, Coombs' reaction, Hajdu reaction, the surface fixation and agglutination reaction and the reaction of complement binding with heterologic antigens. For that purpose the following were used: 1) Serums--antiglobulin against cattle globulin, 5720 serum of various animals which had manifested non-specific agglutination with brucella antigen and brucella serums of experimentally infected sheep, of naturally infected swine and of cattle--received from abroad. 2) Antigens--of Br. abortus 99, of bacteria heterologic to brucellae: Proteus vulgaris, Listeria monocytogenes, Staphylococcus albus, Escherichia coli, Streptococcus pyogenes, S. abortus ovis, for O and OH agglutination, water extraction antigens--for complement binding and concentrated suspensions of all bacteria used in brucellose and non-brucellose serum absorption. Highest number of non-specific reactions were observed in cattle serums and lowest--in goat serums. Titers with heterologic antigens were higher than these with brucella antigens. Often the serum having non-specific agglutiantion reacted not only with one, but with more heterologic antigens. Non-specific complement binding reactions were not produced in complete antibodies with the brucella antigen. Heterologic brucella antigens were exhausted more fully than heterologic complement binding antibodies. In their effectiveness (differentiation of non-specific agglutination with brucella antigen in cattle serum) the serological reactions studied rank as follows: complement binding reaction, slow agglutination with serums absorbed by heterologic antigens, surface fixation reaction, Coombs' reaction, and Hadju agglutination.

  15. Passive immunization with Leptospira LPS-specific agglutinating but not non-agglutinating monoclonal antibodies protect guinea pigs from fatal pulmonary hemorrhages induced by serovar Copenhageni challenge.

    PubMed

    Challa, Sreerupa; Nally, Jarlath E; Jones, Carroll; Sheoran, Abhineet S

    2011-06-15

    Leptospira interrogans serovar Copenhageni causes pulmonary hemorrhages with respiratory failure, a major cause of death in leptospirosis patients. Protective immunity to Leptospira is known to correlate with the production of leptospiral lipopolysaccharide (L-LPS)-specific agglutinating antibodies. We generated L-LPS-specific mouse monoclonal antibodies (MAbs) and investigated if these MAbs can protect guinea pigs against fatal pulmonary hemorrhages caused by serovar Copenhageni. The MAbs L8H4 and L9B11 against 22kDa L-LPS agglutinated leptospires and completely protected guinea pigs from the development of fatal pulmonary hemorrhages by serovar Copenhageni, whereas the MAb L4C1 against 8kDa L-LPS neither agglutinated the bacteria nor protected the animals against the fatal pulmonary hemorrhages. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Differential Lectin Agglutination of Fetal, Dividing-Postnatal, and Malignant Hepatocytes

    PubMed Central

    Becker, F. F.

    1974-01-01

    Numerous studies have reported the capacity of the lectin, concanavalin A, to agglutinate selected cell-types. The finding that cells transformed in culture, embryonic cells, and malignant cells are all agglutinated by this substance, may contribute to our understanding of the oncogenic process. The present study compared the response to concanavalin A of rat hepatocytes derived from livers of differing developmental and mitotic-status as well as those derived from malignant liver tumors (hepatomas). Fetal hepatocytes and hepatoma cells were highly susceptible to agglutination while hepatocytes from post-natal livers, whether dividing or quiescent, were not. Treatment with protease(s) did not make the interphase hepatocyte agglutinable. These data emphasize the importance of examining a wide variety of cells in attempting to understand the interaction of lectins on cell surfaces, and further, demonstrate the value of obtaining cells directly from tissue(s) during differing physiologic and pathologic states. Images PMID:4373708

  17. Surgical management of vulvovaginal agglutination due to lichen planus.

    PubMed

    Fairchild, Pamela S; Haefner, Hope K

    2016-02-01

    Lichen planus is a rare dermatological disorder that is often associated with painful and disfiguring vulvovaginal effects. At the University of Michigan Center for Vulvar Diseases, we see many women with vulvovaginal lichen planus each year, with marked scarring and vulvovaginal agglutination that precludes vaginal intercourse and causes difficulty with urination. Through our experience, we developed a protocol for the operative management and postoperative care for severe vulvovaginal agglutination. Our objective is to share this protocol with a wider audience so that providers who see patients with these devastating effects of lichen planus can benefit from our experience to better serve this patient population. The figure represents a case of erosive lichen planus with early vaginal agglutination. The video reviews the pathophysiology and presentation of lichen planus. We then present a case of scarring and agglutination in a young woman, including our surgical management and postoperative care recommendations. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Nature of a Red Cell Sensitizing Substance from Streptococci1

    PubMed Central

    Jackson, Robert W.; Moskowitz, Merwin

    1966-01-01

    Jackson, Robert W. (Purdue University, Lafayette, Ind.), and Merwin Moskowitz. Nature of a red cell sensitizing substance from streptococci. J. Bacteriol. 91:2205–2209. 1966.—A method for purifying a streptococcal antigen which sensitizes red cells to agglutination by antiserum is described. The antigen, when purified by this method, is almost exclusively composed of glycerophosphate and d-alanine. The ratio of alanine to glycerophosphate varies from 1:5 to 1:3. The glycerophosphate is polymerized and is thus a teichoic acid. The polyglycerophosphate appears to be the antigenic determinant for agglutination. d-Alanine is readily removed by mild base and appears to be necessary for the attachment of the teichoic acid to red cells. Quantitative removal of alanine does not affect the ability of the polymer to absorb antibody from serum. PMID:5329284

  19. Elemental X-ray mapping of agglutinated foraminifer tests: A non- destructive technique for determining compositional characteristics.

    USGS Publications Warehouse

    Commeau, R.F.; Reynolds, Leslie A.; Poag, C.W.

    1985-01-01

    The composition of agglutinated foraminiferal tests vary remarkably in response to local substrate characteristics, physiochemical properties of the water column and species- dependant selectivity of test components. We have employed a technique that combines a scanning electron microscope with an energy dispersive X-ray spectrometer system to identify major and minor elemental constituents of agglutinated foraminiferal walls. As a sample is bombarded with a beam of high energy electrons, X-rays are generated that are characteristic of the elements present. As a result, X- ray density maps can be produced for each of several elements present in the tests of agglutinated foraminifers. 

  20. Comparison of counter-immunoelectrophoresis with other serological tests in the diagnosis of human brucellosis

    PubMed Central

    Díaz, R.; Maravi-Poma, E.; Rivero, A.

    1976-01-01

    Sera from 65 persons with clinical brucellosis were employed in a comparison of standard and rapid serological tests. The results obtained with the Rose Bengal test correlated very well with those of the standard tube agglutination test, whereas results with the rapid plate agglutination test and the Coombs (antiglobulin) test were inferior. Absorption of patients' sera with specific anti-human immunoglobulin sera showed that IgM was active in the Rose Bengal test but not in the Coombs test, whereas IgG and IgA were active in both tests. In addition to the A & M antigen, which plays the most important role in the agglutination, Rose Bengal, and Coombs tests, other antigenic fractions of Brucella were examined in precipitation tests. A protein antigen reacted with 94% of the sera in counter-immunoelectrophoresis. On the basis of the results with both groups of sera, the Rose Bengal test and counter-immunoelectrophoresis appear to be the most promising methods for diagnosing clinical brucellosis. The tests differ qualitatively since different Brucella antigens are employed. PMID:791532

  1. Development and evaluation of an off-the-slide genotyping technique for identifying Giardia cysts and Cryptosporidium oocysts directly from US EPA Method 1623 slides

    EPA Science Inventory

    ABSTRACT Aims This study developed and systematically evaluated performance and limit of detection of an off-the-slide genotyping procedure for both Cryptosporidium oocysts and Giardia cysts. Methods and Results Slide standards containing flow sorted (oo)cysts were used to e...

  2. Discriminating the hemolytic risk of blood type A plasmas using the complement hemolysis using human erythrocytes (CHUHE) assay.

    PubMed

    Cunnion, Kenji M; Hair, Pamela S; Krishna, Neel K; Sass, Megan A; Enos, Clinton W; Whitley, Pamela H; Maes, Lanne Y; Goldberg, Corinne L

    2017-03-01

    The agglutination-based cross-matching method is sensitive for antibody binding to red blood cells but is only partially predictive of complement-mediated hemolysis, which is important in many acute hemolytic transfusion reactions. Here, we describe complement hemolysis using human erythrocytes (CHUHE) assays that directly evaluate complement-mediated hemolysis between individual serum-plasma and red blood cell combinations. The CHUHE assay is used to evaluate correlations between agglutination titers and complement-mediated hemolysis as well as the hemolytic potential of plasma from type A blood donors. Plasma or serum from each type A blood donor was incubated with AB or B red blood cells in the CHUHE assay and measured for free hemoglobin release. CHUHE assays for serum or plasma demonstrate a wide, dynamic range and high sensitivity for complement-mediated hemolysis for individual serum/plasma and red blood cell combinations. CHUHE results suggest that agglutination assays alone are only moderately predictive of complement-mediated hemolysis. CHUHE results also suggest that plasma from particular type A blood donors produce minimal complement-mediated hemolysis, whereas plasma from other type A blood donors produce moderate to high-level complement-mediated hemolysis, depending on the red blood cell donor. The current results indicate that the CHUHE assay can be used to assess complement-mediated hemolysis for plasma or serum from a type A blood donor, providing additional risk discrimination over agglutination titers alone. © 2016 AABB.

  3. Immunogold-agglutination assay for direct detection of HPV-16 E6 and L1 proteins from clinical specimens.

    PubMed

    Bhattarakosol, Parvapan; Plaignam, Kamolwan; Sereemaspun, Amornpun

    2018-05-01

    HPV-16 infection is the most common cause of cervical cancer. As HPV-16 transforms the cell, E6 oncoprotein is over-expressed. Therefore, molecular detection of HPV-16 E6 mRNA is now being used for diagnosis and prediction of cancer development. Besides detecting E6 mRNA, a rapid lateral flow detecting the E6 protein using enzyme immunoassay is also now on market with a sensitivity of 53.5% for cervical intraepithelial neoplasia (CIN)-3 or more severe (CIN-3+). Here, an immunogold-agglutination assay was developed to detect not only HPV-16 E6 protein but also L1, a major capsid protein found in the productive stage of the virus. Evaluation of this test using HPV-16 DNA positive cervical samples showed that the HPV-16 E6 immunogold-agglutination assay results correlated well with the progression of the cervical lesions, i.e., 10.34% of CIN-1, 68.75% of CIN-3 and 80% of cancer (CaCx) and none for healthy normal samples. Interestingly, the HPV-16 L1 protein was found in most of the cases with cancer indicating the possibility of virion production. Immunogold-agglutination assay for E6 protein is simpler, easier to be performed with a sensitivity of 73.1% for CIN-3+ suggesting a good method for laboratory diagnostic use. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Comparison of agglutinating and neutralizing antibodies to serovar hardjo in sows immunized with two commercial whole culture polivalent anti-leptospira bacterins

    PubMed Central

    Soto, Francisco Rafael Martins; Pinheiro, Sônia Regina; Morais, Zenaide Maria; Gonçales, Amane Paldês; de Azevedo, Sérgio Santos; Bernardi, Fernanda; Camargo, Sebastião Rodrigues; Vasconcellos, Silvio Arruda

    2008-01-01

    It was performed the comparison of the intensity and duration of agglutinating and neutralizing antibodies to serovar Hardjo in swines vaccinated with two commercial anti-leptospira bacterins. Sows no reactive to 24 Leptospira sp serovars in the microscopic agglutination test (MAT) were divided in three groups: Group A (n=08): received two vaccine A doses with 30 days interval, Group B (n=08) two vaccine B doses with 30 days interval and Group C (n=08): control no vaccinated against leptospirosis.Blood samples were collected each 30 days during six months following the first vaccination. The sera were tested by MAT and growth inhibition test (GIT) to serovar Hardjo in order to evaluate respectively agglutinating and neutralizing antibodies. It was found that neutralizing antibodies persisted for a longer time than the agglutinating ones and that the absence of agglutinating antibodies does not means in the absence of the neutralizing. The peaks of agglutinating antibodies was obtained at least 30 days earlier than that produced by neutralizing. The duration of both kinds of antibodies measured differed between the two bacterines tested. The period for inducing neutralizing antibodies against serovar Hardjo indicated that gilts must be immunized with two doses of whole culture anti-leptospira bacterines applied 30 days each other at least 90 days before the first mating. For the maintenance of hight levels of neutralizing antibodies the revaccinations must be performed every six months after the first vaccination. PMID:24031250

  5. Lectin-induced agglutination method of urinary exosomes isolation followed by mi-RNA analysis: Application for prostate cancer diagnostic.

    PubMed

    Samsonov, Roman; Shtam, Tatiana; Burdakov, Vladimir; Glotov, Andrey; Tsyrlina, Evgenia; Berstein, Lev; Nosov, Alexander; Evtushenko, Vladimir; Filatov, Michael; Malek, Anastasia

    2016-01-01

    Prostate cancer is the most common cancer in men. Prostate-specific antigen has, however, insufficient diagnostic specificity. Novel complementary diagnostic approaches are greatly needed. MiRNAs are small regulatory RNAs which play an important role in tumorogenesis and are being investigated as a cancer biomarker. In addition to their intracellular regulatory functions, miRNAs are secreted into the extracellular space and can be found in various body fluids, including urine. The stability of extracellular miRNAs is defined by association with proteins, lipoprotein particles, and membrane vesicles. Among the known forms of miRNA packaging, tumour-derived exosome-enclosed miRNAs is thought to reflect the vital activity of cancer cells. The assessment of the exosomal fraction of urinary miRNA may present a new and highly specific method for prostate cancer diagnostics; however, this is challenged by the absence of reliable and inexpensive methods for isolation of exosomes. Prostate cancer (PC) cell lines and urine samples collected from 35 PC patients and 35 healthy donors were used in the study. Lectins, phytohemagglutinin, and concanavalin A were used to induce agglutination of exosomes. The efficiency of isolation process was evaluated by AFM and DLS assays. The protein content of isolated exosomes was analysed by western blotting. Exosomal RNA was assayed by automated electrophoresis and expression level of selected miRNAs was evaluated by RT-qPCR. The diagnostic potency of the urinary exosomal miRNA assessment was estimated by the ROC method. The formation of multi-vesicular agglutinates in urine can be induced by incubation with lectin at a final concentration of 2 mg/ml. These agglutinates contain urinary exosomes and may be pelleted by centrifugation with a relatively low G-force. The analysis of PC-related miRNA in urinary exosomes revealed significant up-regulation of miR-574-3p, miR-141-5p, and miR-21-5p associated with PC. Lectin-induced aggregation is a low-cost and easily performed method for isolation of exosomes from urine. Isolated exosomes can be further analysed in terms of miRNA content. The miRNA profile of urinary exosomes reflects development of prostate cancer and may present a promising diagnostic tool. © 2015 Wiley Periodicals, Inc.

  6. Adaptive Actor-Critic Design-Based Integral Sliding-Mode Control for Partially Unknown Nonlinear Systems With Input Disturbances.

    PubMed

    Fan, Quan-Yong; Yang, Guang-Hong

    2016-01-01

    This paper is concerned with the problem of integral sliding-mode control for a class of nonlinear systems with input disturbances and unknown nonlinear terms through the adaptive actor-critic (AC) control method. The main objective is to design a sliding-mode control methodology based on the adaptive dynamic programming (ADP) method, so that the closed-loop system with time-varying disturbances is stable and the nearly optimal performance of the sliding-mode dynamics can be guaranteed. In the first step, a neural network (NN)-based observer and a disturbance observer are designed to approximate the unknown nonlinear terms and estimate the input disturbances, respectively. Based on the NN approximations and disturbance estimations, the discontinuous part of the sliding-mode control is constructed to eliminate the effect of the disturbances and attain the expected equivalent sliding-mode dynamics. Then, the ADP method with AC structure is presented to learn the optimal control for the sliding-mode dynamics online. Reconstructed tuning laws are developed to guarantee the stability of the sliding-mode dynamics and the convergence of the weights of critic and actor NNs. Finally, the simulation results are presented to illustrate the effectiveness of the proposed method.

  7. Rapid detection of hemagglutination using restrictive microfluidic channels equipped with waveguide-mode sensors

    NASA Astrophysics Data System (ADS)

    Ashiba, Hiroki; Fujimaki, Makoto; Awazu, Koichi; Fu, Mengying; Ohki, Yoshimichi; Tanaka, Torahiko; Makishima, Makoto

    2016-02-01

    Hemagglutination is utilized for various immunological assays, including blood typing and virus detection. Herein, we describe a method of rapid hemagglutination detection based on a microfluidic channel installed on an optical waveguide-mode sensor. Human blood samples mixed with hemagglutinating antibodies associated with different blood groups were injected into the microfluidic channel, and reflectance spectra of the samples were measured after stopping the flow. The agglutinated and nonagglutinated samples were distinguishable by the alterations in their reflectance spectra with time; the microfluidic channels worked as spatial restraints for agglutinated red blood cells. The demonstrated system allowed rapid hemagglutination detection within 1 min. The suitable height of the channels was also discussed.

  8. Analysis of the 3D structure og agglutinated erythrocyte using CellScan and confocal microscopy: characterization by FLIM-FRET

    NASA Astrophysics Data System (ADS)

    Riquelme, Bibiana D.; Dumas, Dominique; Valverde de Rasia, Juana; Rasia, Rodolfo J.; Stoltz, Jean Francois

    2003-10-01

    We report the adhesion of human erythrocyte membranes mediated by monoclonal antibodies anti-glycophorin. The distribution of the linked antibodies on membrane was identified with selective fluorescence labels. To analyze the antibody distribution on interfacial region between two cells agglutinated and on its surface, three types of fluorescence marked strategy were evaluated. The 3D images were obtained in a CellScan and Confocal Laser Scanning Microscopy CLSM. We considered the FRET signal to characterize the agglutination of Red Blood Cells (RBC) by specific monoclonal antibodies (anti-glycophorin A or B). The fluorescence labeling demonstrated that distribution of antibody on erythrocyte membranes is not homogeneous. The fluorescence intensity on contact region in the agglutinated is bigger than the intensity on exterior surface. Tentatively, we interpreted these intensity differences in terms of the mobility of antibody linked to the glycocalix on cell surface. Such mobility has a large consequence in the morphology of cellular agglutinated.

  9. A Transformational Approach to Slip-Slide Factoring

    ERIC Educational Resources Information Center

    Steckroth, Jeffrey

    2015-01-01

    In this "Delving Deeper" article, the author introduces the slip-slide method for solving Algebra 1 mathematics problems. This article compares the traditional method approach of trial and error to the slip-slide method of factoring. Tools that used to be taken for granted now make it possible to investigate relationships visually,…

  10. Genetic basis for loss of immuno-reactive O-chain in Salmonella enterica serovar Enteritidis veterinary isolates.

    PubMed

    Szabo, Istvan; Grafe, Marianne; Kemper, Nicole; Junker, Ernst; Malorny, Burkhard

    2017-05-01

    Fifty-two rough Salmonella enterica serovar Enteritidis (S. Enteritidis) isolates from broilers and the environment were characterized for their serological and genotypic properties. Under routine diagnostic serotyping methods such isolates lack the immuno-reactivity of the O-chain of the lipopolysaccharide (LPS), and are referred to as non-typeable. Using a modified slide agglutination method, the isolates could be differentiated into three different serological variants. Twenty-six isolates (50%) were defined as semi-rough, nineteen isolates (37%) as deep-rough, four isolates (8%) as rough and three isolates could not be assigned. Genetically, all semi-rough isolates lacked the wzyB gene encoding the O-antigen polymerase. Two isolates carried a frameshift mutation in wzyB. In 15 of 23 cases deep-rough or rough isolates had a single point mutation, a single - or double-nucleotide insert or deletion in the wbaP gene. The mutational changes lead to expression of truncated (premature) protein, resulting in the loss of the immuno-reactive O-chain. Both rough and smooth S. Enteritidis isolates showed identical or highly similar XbaI-PFGE profiles. Our results indicate that the loss of a functional LPS in S. Enteritidis isolates is caused by a variety of different mutation events within the wzyB (semi-rough) or the wbaP (deep-rough) gene and is not a result of a vertical spread of a specific S. Enteritidis subtype. The defect of the LPS may be a common evolutionary mechanism through which host defence can be escaped. Copyright © 2017. Published by Elsevier B.V.

  11. Efficacy of a chairside diagnostic test kit for estimation of C-reactive protein levels in periodontal disease.

    PubMed

    Nagarale, Girish; Ravindra, S; Thakur, Srinath; Setty, Swati

    2010-10-01

    C-reactive protein [CRP] levels increase to hundreds of mg/mL within hours following infection. Studies have shown that serum CRP levels were elevated in periodontal disease. However, in all the previous studies, CRP levels were measured by using high-sensitivity CRP assay kits with minimal detection limits of 0.1 to 3 mg/L, which was much below the normal value of 10 mg/L. These high-sensitivity CRP assays need a proper laboratory setup, and these methods cannot be used as a routine chair-side test in the dental office. The purpose of this study was to investigate the serum CRP levels in subjects with periodontal disease by using a rapid chair-side diagnostic test kit with a lower detection limit of 6 mg/L and to compare the CRP levels before and after periodontal therapy. A total of 45 systemically healthy subjects were selected for the study. Subjects were divided into three groups: group A: healthy controls, group B: gingivitis, group C: periodontitis. Serum levels of CRP were determined by using a latex slide agglutination method with commercially available kit with lower detection limit of 6 mg/L. CRP was negative in all the 15 subjects in groups A and B at baseline, 7th and 30th day. CRP was positive only in 2 subjects in Group C at baseline and 7th day. Estimation of serum CRP by using a rapid chair-side diagnostic test kit is not of any significance in subjects with periodontitis.

  12. Effects of processing and in vitro proteolytic digestion on soybean and yambean hemagglutinins.

    PubMed

    Ojimelukwe, P C; Onuoha, C C; Obanu, Z A

    1995-06-01

    Some conventional processing methods were applied on yambean and soybean seeds and flour samples. They include soaking fermentation, cooking whole seeds in the presence and absence of trona, autoclaving and dry heat treatment of flour samples. Hemagglutinating activity was assayed for after processing treatments. The hemagglutinating proteins from these seeds were classified based on their solubility properties. Effects of the presence of 0.01% concentration of trypsin, pepsin and proteases on agglutination of human red blood cells were also evaluated. Most processing methods, particularly cooking whole seeds for 1-2 h, soaking and fermentation, reduced hemagglutinating activity on cow red blood cells. Size reduction accompanied by heat treatment was effective in eliminating hemagglutination. Both the albumin and globulin fractions of the soybean showed hemagglutinating activity but only the albumin fraction of the yambean had agglutinating properties. Proteolytic action of proteases was more effective in reduction of hemagglutinating activity than that of trypsin and pepsin.

  13. Molecular diagnosis of non-serotypeable Shigella spp.: problems and prospects.

    PubMed

    Muthuirulandi Sethuvel, Dhiviya Prabaa; Devanga Ragupathi, Naveen Kumar; Anandan, Shalini; Walia, Kamini; Veeraraghavan, Balaji

    2017-02-01

    It is not always possible to identify Shigella serogroups/serotypes by biochemical properties alone. Specific identification requires serotyping. Occasionally, isolates that resemble Shigella spp. biochemically, but are non-agglutinable with available antisera, have been observed. Several mechanisms have been reported to limit the efficiency of the serotyping assay. Serotype conversion is a major mechanism in Shigella spp. to escape protective host immune responses. This easy conversion through significant modification of the O-antigen backbone results in different serotypes, which makes laboratory identification difficult. Furthermore, members of the family Enterobacteriaceae are closely related and there is antigenic cross-over (intra- and inter-specific cross-reaction) which affects the agglutination reaction. The performance of the available methods for identification of non-serotypeable Shigella is discussed here, and reveals them to be non-reliable. This shows a need for an alternative method for identification and typing of Shigella spp.

  14. Time-varying sliding-coefficient-based decoupled terminal sliding-mode control for a class of fourth-order systems.

    PubMed

    Bayramoglu, Husnu; Komurcugil, Hasan

    2014-07-01

    A time-varying sliding-coefficient-based decoupled terminal sliding mode control strategy is presented for a class of fourth-order systems. First, the fourth-order system is decoupled into two second-order subsystems. The sliding surface of each subsystem was designed by utilizing time-varying coefficients. Then, the control target of one subsystem to another subsystem was embedded. Thereafter, a terminal sliding mode control method was utilized to make both subsystems converge to their equilibrium points in finite time. The simulation results on the inverted pendulum system demonstrate that the proposed method exhibits a considerable improvement in terms of a faster dynamic response and lower IAE and ITAE values as compared with the existing decoupled control methods. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  15. Adaptive Localization of Focus Point Regions via Random Patch Probabilistic Density from Whole-Slide, Ki-67-Stained Brain Tumor Tissue

    PubMed Central

    Alomari, Yazan M.; MdZin, Reena Rahayu

    2015-01-01

    Analysis of whole-slide tissue for digital pathology images has been clinically approved to provide a second opinion to pathologists. Localization of focus points from Ki-67-stained histopathology whole-slide tissue microscopic images is considered the first step in the process of proliferation rate estimation. Pathologists use eye pooling or eagle-view techniques to localize the highly stained cell-concentrated regions from the whole slide under microscope, which is called focus-point regions. This procedure leads to a high variety of interpersonal observations and time consuming, tedious work and causes inaccurate findings. The localization of focus-point regions can be addressed as a clustering problem. This paper aims to automate the localization of focus-point regions from whole-slide images using the random patch probabilistic density method. Unlike other clustering methods, random patch probabilistic density method can adaptively localize focus-point regions without predetermining the number of clusters. The proposed method was compared with the k-means and fuzzy c-means clustering methods. Our proposed method achieves a good performance, when the results were evaluated by three expert pathologists. The proposed method achieves an average false-positive rate of 0.84% for the focus-point region localization error. Moreover, regarding RPPD used to localize tissue from whole-slide images, 228 whole-slide images have been tested; 97.3% localization accuracy was achieved. PMID:25793010

  16. [Analysis for Discordance of Positive and Negative Blood Typing by Gel Card].

    PubMed

    Li, Cui-Ying; Xu, Hong; Lei, Hui-Fen; Liu, Juan; Li, Xiao-Wei

    2017-08-01

    To explore the method of Gel card identifying ABO blood group, determine the inconsistent cause and the distribution of disease affecting factors, and put forward a method of its solutions. To collect 240 positive and negative typing-discordant blood speciments from patients examined by Gel card and send these speciments to blood type reference laboratory for examining with the classic tube method and serological test, such as salivary blood-group substance, in order to performe genotyping method when serologic test can not be determined. Among 240 positive and negative typing-discordant blood speciments from patients examined by Gel card, 107 blood speciments were positive and negative consistent examined by false agglutination test (44.58%), 133 blood specinents were discordent examined by false agglutination (55.42%), out of them, 35 cases (14.58%) with inconsistent cold agglutination test, 22 cases (9.17%) with weakened AB antigenicity, 16 cases (6.67%) with ABO subtyping, 12 cases (5.00%) with positive direct antiglobulin test, 11 cases (4.58%) with reduced or without antibodies, 11 cases (4.58%) with false aggregation caused by drugs or protein, 11 cases (4.58%) with salivary blood-type substances, 8 cases (3.33%) with non-ABO alloantibody, and 7 cases (2.92%) with allogeneic bone marrow transplantation. The distribution of disease were following: blood disease (16.83%), tumor (11.88%), and cardiopulmonary diseases (11.39%); chi-square test results indicated that the distribution significantly different. The analysis of ABO blood grouping shows a variety factors influencing positive and negative blood typing, and the Gel Card identification can produc more false positive blood types. Therefore, more attention should be paid on the high incidence diseases, such as blood disease, tumor, and cardiopulmonary disease.

  17. Comparison of Non-Culture-Based Methods for Detection of Systemic Fungal Infections, with an Emphasis on Invasive Candida Infections

    PubMed Central

    White, P. Lewis; Archer, Alice E.; Barnes, Rosemary A.

    2005-01-01

    The accepted limitations associated with classic culture techniques for the diagnosis of invasive fungal infections have lead to the emergence of many non-culture-based methods. With superior sensitivities and quicker turnaround times, non-culture-based methods may aid the diagnosis of invasive fungal infections. In this review of the diagnostic service, we assessed the performances of two antigen detection techniques (enzyme-linked immunosorbent assay [ELISA] and latex agglutination) with a molecular method for the detection of invasive Candida infection and invasive aspergillosis. The specificities for all three assays were high (≥97%), although the Candida PCR method had enhanced sensitivity over both ELISA and latex agglutination with values of 95%, 75%, and 25%, respectively. However, calculating significant sensitivity values for the Aspergillus detection methods was not feasible due to a low number of proven/probable cases. Despite enhanced sensitivity, the PCR method failed to detect nucleic acid in a probable case of invasive Candida infection that was detected by ELISA. In conclusion, both PCR and ELISA techniques should be used in unison to aid the detection of invasive fungal infections. PMID:15872239

  18. EDTA-temperature-Induced pseudohematocytopenia in a patient with multiple myeloma.

    PubMed

    Zhang, Lixia; Pan, Shiyang; Zhang, Jie; Lu, Lin; Xie, Erfu; Ye, Qin

    2012-01-01

    Platelet clumping caused by ethylenediamine tetraacetic acid (EDTA) and erythrocyte agglutination caused by cold agglutinins are often found in clinical findings. However, erythrocyte agglutination induced by EDTA has not been reported as yet. Spurious low red blood cell (RBC), white blood cell (WBC), and platelet counts were observed in a patient blood sample collected in EDTA in vitro at room temperature and 37 degrees C. However, the phenomena were only observed in the sodium citrate and heparin anticoagulated blood at room temperature, but not at 37 degrees C. Both erythrocyte agglutination and platelet clumping were observed in the peripheral blood smear. These data suggest an EDTA-temperature-induced pseudohematocytopenia. It is a very rare phenomenon to observe erythrocyte agglutination induced by EDTA and temperature.

  19. Method and system for ultra-precision positioning

    DOEpatents

    Montesanti, Richard C.; Locke, Stanley F.; Thompson, Samuel L.

    2005-01-11

    An apparatus and method is disclosed for ultra-precision positioning. A slide base provides a foundational support. A slide plate moves with respect to the slide base along a first geometric axis. Either a ball-screw or a piezoelectric actuator working separate or in conjunction displaces the slide plate with respect to the slide base along the first geometric axis. A linking device directs a primary force vector into a center-line of the ball-screw. The linking device consists of a first link which directs a first portion of the primary force vector to an apex point, located along the center-line of the ball-screw, and a second link for directing a second portion of the primary force vector to the apex point. A set of rails, oriented substantially parallel to the center-line of the ball-screw, direct movement of the slide plate with respect to the slide base along the first geometric axis and are positioned such that the apex point falls within a geometric plane formed by the rails. The slide base, the slide plate, the ball-screw, and the linking device together form a slide assembly. Multiple slide assemblies can be distributed about a platform. In such a configuration, the platform may be raised and lowered, or tipped and tilted by jointly or independently displacing the slide plates.

  20. A Computer System for Making Quick and Economical Color Slides.

    ERIC Educational Resources Information Center

    Pryor, Harold George

    1986-01-01

    A computer-based method for producing 35mm color slides has been used in Ohio State University's College of Dentistry. The method can produce both text and slides in less than two hours, providing substantial flexibility in planning and revising visual presentations. (Author/MLW)

  1. Recognition of the Species of Origin of Cells in Culture by Mixed Agglutination

    PubMed Central

    Coombs, R. R. A.; Daniel, Mary R.; Gurner, B. W.; Kelus, A.

    1961-01-01

    Preliminary experiment on the mixed agglutination reaction suggests that this reaction will afford a useful method for identifying the species of origin of cells maintained in culture. The reaction depends on the presence of antigens characteristic of the species, common to both tissue cells and red cells. Culture cells derived from man, ox, pig and rat could be distinguished one from the other. Fibroblasts of the mouse may be differentiated from those of the rat by means of a rat anti-mouse red-cell serum or a mouse anti-rat red-cell serum. Experiments are reported on trial absorption procedures to render the sera completely species-specific in their reactions. ImagesFIG. 1 PMID:13695283

  2. Erythrocyte agglutination by wheat germ agglutinin: ionic strength dependence of the contact seam topology.

    PubMed

    Rolfe, M; Parmar, A; Hoy, T G; Coakley, W T

    2001-01-01

    The topology of the cell-cell contact seam formed when normal or pronase pre-treated (PPT) erythrocytes are exposed to wheat germ agglutinin (WGA) in isotonic media of different ionic strengths was examined here. Lectin uptake and cell agglutination were also quantified. Agglutination of normal cells was gradually and significantly inhibited as ionic strength (IS) was reduced from 0.15 (buffered 145 mm NaCl) to 0.105. Agglutination was less inhibited in PPT cells, even when IS was reduced to 0.09. Cell contact seams formed during agglutination showed patterns of localized contacts. The scale of the patterns, i.e. the average lateral separation distance of contact regions, was 0.62 microm for normal cells and was significantly shorter, at 0.44 microm, for PPT cells at an IS of 0.15. The scale increased significantly for both cell types when the IS was reduced to 0.09. Flow cytometry measurements showed that WGA uptake by normal cells increased slightly, whilst that for PPT cells was unchanged, as IS was decreased from 0.15 to 0.09. The results imply that, whilst ionic strength change does not exert a strong influence on intermolecular WGA-ligand binding, physico-chemical modification of the interaction between cells modulates not only the extent and progression of the biospecific lectin-induced cell-cell agglutination but also the topology of the contact seam. The IS dependence of contact separation in WGA-agglutinated cells is contrasted here with that reported for cells adhering in dextran solutions. The influence of IS change and pronase pre-treatment on contact pattern are consistent with predictions, from interfacial instability theory, of punctuate thinning of the aqueous layer separating bilayer membranes in close apposition.

  3. STUDIES OF ANTIGENIC DIFFERENCES AMONG STRAINS OF INFLUENZA A BY MEANS OF RED CELL AGGLUTINATION

    PubMed Central

    Hirst, George K.

    1943-01-01

    A study of cross inhibition tests among strains of influenza A virus and their antisera showed that the results obtained were subject to a certain amount of variation due to the red cells, the virus suspensions, and the ferret antisera employed. Methods have been demonstrated for handling the data obtained from such tests, so that these variables were corrected or avoided, making it possible to use the agglutination technique for antigenic comparisons. The antigenic pattern of eighteen strains of influenza A virus, obtained from the 1940–41 epidemic in the United States, has been compared by means of agglutination inhibition tests with ferret antisera. No significant antigenic differences were found among sixteen of these strains (all isolated from throat washings by the inoculation of chick embryos) although they were obtained from individuals in widely separated regions of the country. Two strains, from cases occurring early in the epidemic and isolated from throat washings by ferret and mouse passage, showed a slight but significant strain difference from the other strains and from each other. One of the 1940–41 strains on cross test resembled the PR8 strain more closely than any other stock strain tested. PMID:19871338

  4. Agglutination Assays of the Plasmodium falciparum-Infected Erythrocyte.

    PubMed

    Tan, Joshua; Bull, Peter C

    2015-01-01

    The agglutination assay is used to determine the ability of antibodies to recognize parasite variant antigens on the surface of Plasmodium falciparum-infected erythrocytes. In this technique, infected erythrocytes are selectively labelled with a DNA-binding fluorescent dye and mixed with antibodies of interest to allow antibody-surface antigen binding. Recognition of surface antigens by the antibodies can result in the formation of agglutinates containing multiple parasite-infected erythrocytes. These can be viewed and quantified using a fluorescence microscope.

  5. Antimicrobial Action and Cell Agglutination by the Eosinophil Cationic Protein Are Modulated by the Cell Wall Lipopolysaccharide Structure

    PubMed Central

    Pulido, David; Moussaoui, Mohammed; Andreu, David; Nogués, M. Victòria

    2012-01-01

    Antimicrobial proteins and peptides (AMPs) are essential effectors of innate immunity, acting as a first line of defense against bacterial infections. Many AMPs exhibit high affinity for cell wall structures such as lipopolysaccharide (LPS), a potent endotoxin able to induce sepsis. Hence, understanding how AMPs can interact with and neutralize LPS endotoxin is of special relevance for human health. Eosinophil cationic protein (ECP) is an eosinophil secreted protein with high activity against both Gram-negative and Gram-positive bacteria. ECP has a remarkable affinity for LPS and a distinctive agglutinating activity. By using a battery of LPS-truncated E. coli mutant strains, we demonstrate that the polysaccharide moiety of LPS is essential for ECP-mediated bacterial agglutination, thereby modulating its antimicrobial action. The mechanism of action of ECP at the bacterial surface is drastically affected by the LPS structure and in particular by its polysaccharide moiety. We have also analyzed an N-terminal fragment that retains the whole protein activity and displays similar cell agglutination behavior. Conversely, a fragment with further minimization of the antimicrobial domain, though retaining the antimicrobial capacity, significantly loses its agglutinating activity, exhibiting a different mechanism of action which is not dependent on the LPS composition. The results highlight the correlation between the protein's antimicrobial activity and its ability to interact with the LPS outer layer and promote bacterial agglutination. PMID:22330910

  6. Antimicrobial action and cell agglutination by the eosinophil cationic protein are modulated by the cell wall lipopolysaccharide structure.

    PubMed

    Pulido, David; Moussaoui, Mohammed; Andreu, David; Nogués, M Victòria; Torrent, Marc; Boix, Ester

    2012-05-01

    Antimicrobial proteins and peptides (AMPs) are essential effectors of innate immunity, acting as a first line of defense against bacterial infections. Many AMPs exhibit high affinity for cell wall structures such as lipopolysaccharide (LPS), a potent endotoxin able to induce sepsis. Hence, understanding how AMPs can interact with and neutralize LPS endotoxin is of special relevance for human health. Eosinophil cationic protein (ECP) is an eosinophil secreted protein with high activity against both Gram-negative and Gram-positive bacteria. ECP has a remarkable affinity for LPS and a distinctive agglutinating activity. By using a battery of LPS-truncated E. coli mutant strains, we demonstrate that the polysaccharide moiety of LPS is essential for ECP-mediated bacterial agglutination, thereby modulating its antimicrobial action. The mechanism of action of ECP at the bacterial surface is drastically affected by the LPS structure and in particular by its polysaccharide moiety. We have also analyzed an N-terminal fragment that retains the whole protein activity and displays similar cell agglutination behavior. Conversely, a fragment with further minimization of the antimicrobial domain, though retaining the antimicrobial capacity, significantly loses its agglutinating activity, exhibiting a different mechanism of action which is not dependent on the LPS composition. The results highlight the correlation between the protein's antimicrobial activity and its ability to interact with the LPS outer layer and promote bacterial agglutination.

  7. Experimental shock metamorphism of terrestrial basalts: Agglutinate-like particle formation, petrology, and magnetism

    NASA Astrophysics Data System (ADS)

    Badyukov, Dmitrii D.; Bezaeva, Natalia S.; Rochette, Pierre; Gattacceca, Jérôme; Feinberg, Joshua M.; Kars, Myriam; Egli, Ramon; Raitala, Jouko; Kuzina, Dilyara M.

    2018-01-01

    Hypervelocity impacts occur on bodies throughout our solar system, and play an important role in altering the mineralogy, texture, and magnetic properties in target rocks at nanometer to planetary scales. Here we present the results of hypervelocity impact experiments conducted using a two-stage light-gas gun with 5 mm spherical copper projectiles accelerated toward basalt targets with 6 km s-1 impact velocities. Four different types of magnetite- and titanomagnetite-bearing basalts were used as targets for seven independent experiments. These laboratory impacts resulted in the formation of agglutinate-like particles similar in texture to lunar agglutinates, which are an important fraction of lunar soil. Materials recovered from the impacts were examined using a suite of complementary techniques, including optical and scanning electron microscopy, micro-Raman spectroscopy, and high- and low-temperature magnetometry, to investigate the texture, chemistry, and magnetic properties of newly formed agglutinate-like particles and were compared to unshocked basaltic parent materials. The use of Cu-projectiles, rather than Fe- and Ni-projectiles, avoids magnetic contamination in the final shock products and enables a clearer view of the magnetic properties of impact-generated agglutinates. Agglutinate-like particles show shock features, such as melting and planar deformation features, and demonstrate shock-induced magnetic hardening (two- to seven-fold increases in the coercivity of remanence Bcr compared to the initial target materials) and decreases in low-field magnetic susceptibility and saturation magnetization.

  8. Host-Guest Complexes of Cyclodextrins and Nanodiamonds as a Strong Non-Covalent Binding Motif for Self-Assembled Nanomaterials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schibilla, Frauke; Voskuhl, Jens; Fokina, Natalie A.

    We report the inclusion of carboxy- and amine-substituted molecular nanodiamonds (NDs) adamantane, diamantane, and triamantane by β-cyclodextrin and γ-cyclodextrin (β-CD and γ-CD), which have particularly well-suited hydrophobicity and symmetry for an optimal fit of the host and guest molecules. We studied the host–guest interactions in detail and generally observed 1:1 association of the NDs with the larger γ-CD cavity, but observed 1:2 association for the largest ND in the series (triamantane) with β-CD. Here, we found higher binding affinities for carboxy-substituted NDs than for amine-substituted NDs. Additionally, cyclodextrin vesicles (CDVs) were decorated with d-mannose by using adamantane, diamantane, and triamantanemore » as non-covalent anchors, and the resulting vesicles were compared with the lectin concanavalin A in agglutination experiments. Agglutination was directly correlated to the host–guest association: adamantane showed lower agglutination than di- or triamantane with β-CDV and almost no agglutination with γ-CDV, whereas high agglutination was observed for di- and triamantane with γ-CDV.« less

  9. Host-Guest Complexes of Cyclodextrins and Nanodiamonds as a Strong Non-Covalent Binding Motif for Self-Assembled Nanomaterials

    DOE PAGES

    Schibilla, Frauke; Voskuhl, Jens; Fokina, Natalie A.; ...

    2017-11-06

    We report the inclusion of carboxy- and amine-substituted molecular nanodiamonds (NDs) adamantane, diamantane, and triamantane by β-cyclodextrin and γ-cyclodextrin (β-CD and γ-CD), which have particularly well-suited hydrophobicity and symmetry for an optimal fit of the host and guest molecules. We studied the host–guest interactions in detail and generally observed 1:1 association of the NDs with the larger γ-CD cavity, but observed 1:2 association for the largest ND in the series (triamantane) with β-CD. Here, we found higher binding affinities for carboxy-substituted NDs than for amine-substituted NDs. Additionally, cyclodextrin vesicles (CDVs) were decorated with d-mannose by using adamantane, diamantane, and triamantanemore » as non-covalent anchors, and the resulting vesicles were compared with the lectin concanavalin A in agglutination experiments. Agglutination was directly correlated to the host–guest association: adamantane showed lower agglutination than di- or triamantane with β-CDV and almost no agglutination with γ-CDV, whereas high agglutination was observed for di- and triamantane with γ-CDV.« less

  10. Registration of organs with sliding interfaces and changing topologies

    NASA Astrophysics Data System (ADS)

    Berendsen, Floris F.; Kotte, Alexis N. T. J.; Viergever, Max A.; Pluim, Josien P. W.

    2014-03-01

    Smoothness and continuity assumptions on the deformation field in deformable image registration do not hold for applications where the imaged objects have sliding interfaces. Recent extensions to deformable image registration that accommodate for sliding motion of organs are limited to sliding motion along approximately planar surfaces or cannot model sliding that changes the topological configuration in case of multiple organs. We propose a new extension to free-form image registration that is not limited in this way. Our method uses a transformation model that consists of uniform B-spline transformations for each organ region separately, which is based on segmentation of one image. Since this model can create overlapping regions or gaps between regions, we introduce a penalty term that minimizes this undesired effect. The penalty term acts on the surfaces of the organ regions and is optimized simultaneously with the image similarity. To evaluate our method registrations were performed on publicly available inhale-exhale CT scans for which performances of other methods are known. Target registration errors are computed on dense landmark sets that are available with these datasets. On these data our method outperforms the other methods in terms of target registration error and, where applicable, also in terms of overlap and gap volumes. The approximation of the other methods of sliding motion along planar surfaces is reasonably well suited for the motion present in the lung data. The ability of our method to handle sliding along curved boundaries and for changing region topology configurations was demonstrated on synthetic images.

  11. An Automated Blur Detection Method for Histological Whole Slide Imaging

    PubMed Central

    Moles Lopez, Xavier; D'Andrea, Etienne; Barbot, Paul; Bridoux, Anne-Sophie; Rorive, Sandrine; Salmon, Isabelle; Debeir, Olivier; Decaestecker, Christine

    2013-01-01

    Whole slide scanners are novel devices that enable high-resolution imaging of an entire histological slide. Furthermore, the imaging is achieved in only a few minutes, which enables image rendering of large-scale studies involving multiple immunohistochemistry biomarkers. Although whole slide imaging has improved considerably, locally poor focusing causes blurred regions of the image. These artifacts may strongly affect the quality of subsequent analyses, making a slide review process mandatory. This tedious and time-consuming task requires the scanner operator to carefully assess the virtual slide and to manually select new focus points. We propose a statistical learning method that provides early image quality feedback and automatically identifies regions of the image that require additional focus points. PMID:24349343

  12. Diagnostic digital cytopathology: Are we ready yet?

    PubMed Central

    House, Jarret C.; Henderson-Jackson, Evita B.; Johnson, Joseph O.; Lloyd, Mark C.; Dhillon, Jasreman; Ahmad, Nazeel; Hakam, Ardeshir; Khalbuss, Walid E.; Leon, Marino E.; Chhieng, David; Zhang, Xiaohui; Centeno, Barbara A.; Bui, Marilyn M.

    2013-01-01

    Background: The cytology literature relating to diagnostic accuracy using whole slide imaging is scarce. We studied the diagnostic concordance between glass and digital slides among diagnosticians with different profiles to assess the readiness of adopting digital cytology in routine practice. Materials and Methods: This cohort consisted of 22 de-identified previously screened and diagnosed cases, including non-gynecological and gynecological slides using standard preparations. Glass slides were digitalized using Aperio ScanScope XT (×20 and ×40). Cytopathologists with (3) and without (3) digital experience, cytotechnologists (4) and senior pathology residents (2) diagnosed the digital slides independently first and recorded the results. Glass slides were read and recorded separately 1-3 days later. Accuracy of diagnosis, time to diagnosis and diagnostician's profile were analyzed. Results: Among 22 case pairs and four study groups, correct diagnosis (93% vs. 86%) was established using glass versus digital slides. Both methods more (>95%) accurately diagnosed positive cases than negatives. Cytopathologists with no digital experience were the most accurate in digital diagnosis, even the senior members. Cytotechnologists had the fastest diagnosis time (3 min/digital vs. 1.7 min/glass), but not the best accuracy. Digital time was 1.5 min longer than glass-slide time/per case for cytopathologists and cytotechnologists. Senior pathology residents were slower and less accurate with both methods. Cytopathologists with digital experience ranked 2nd fastest in time, yet last in accuracy for digital slides. Conclusions: There was good overall diagnostic agreement between the digital whole-slide images and glass slides. Although glass slide diagnosis was more accurate and faster, the results of technologists and pathologists with no digital cytology experience suggest that solid diagnostic ability is a strong indicator for readiness of digital adoption. PMID:24392242

  13. The relationship between fluorescent, agglutinating, and precipitating antibodies to Candida albicans and their immunoglobin classes

    PubMed Central

    Lehner, T.; Buckley, Helen R.; Murray, I. G.

    1972-01-01

    A parallel study of fluorescent, agglutinating, and precipitating antibodies to Candida albicans revealed that precipitating antibodies belong to the IgG class, whereas agglutinating antibodies reside in the IgG, IgM, and IgA classes. The three types as well as the three classes of antibodies were found in Candida endocarditis and mucocutaneous candidiasis. Immuno-absorption studies suggest that the three serological tests estimate antibodies to mannan determinants of Candida albicans. Images PMID:4555044

  14. Haemagglutination and surface structures in strains of Clostridium spiroforme.

    PubMed

    Baldassarri, L; Pantosti, A; Caprioli, A; Mastrantonio, P; Donelli, G

    1989-07-01

    Five strains of Clostridium spiroforme were examined for their surface properties. All strains were able to agglutinate human erythrocytes. Electron microscopy showed a ruthenium red-positive capsule mediating the attachment of bacteria to erythrocytes. Two strains, showing the lowest degree of haemagglutination, exhibited an additional external layer of filamentous structures, possibly interfering with the agglutinating activity. In spite of their agglutinating ability, the C. spiroforme strains did not show surface hydrophobicity, thus suggesting the possible existence of a new type of clostridial adhesin.

  15. PubMed Central

    Petithory, J. C.; Ambroise-Thomas, P.; De Loye, J.; Pelloux, H.; Goullier-Fleuret, A.; Milgram, M.; Buffard, C.; Garin, J. P.

    1996-01-01

    Reported are the results of a multicentre study involving 40 laboratories that was carried out in France to assess all the currently available methods used for the serodiagnosis of toxoplasmosis. For this purpose 10 batches of control sera were prepared with titres in the range 0-260 IU per ml. These sera were tested in nine laboratories using immunofluorescence methods; in three laboratories using dye tests; in forty laboratories using enzyme-linked immunosorbent assay; in four laboratories using direct agglutination and haemagglutination; in seven laboratories using the high-sensitivity IgG agglutination test; and in three laboratories using the latex agglutination test. In this way, 70 series of titrations were carried out using seven procedures and the results were compared with those obtained using the WHO reference serum in 15 cases, with the French national E6 serum in 16 other cases, and in 39 cases using 15 reference sera supplied by the reagent manufacturers. Rigorous comparison of the tests was not possible in all cases because one aim of the study was to ensure that the tests were carried out under the usual working conditions that prevailed in the participating laboratories. The results obtained indicate that the serological tests currently available for toxoplasmosis are acceptable for its serodiagnosis. Presentation of the titres in IU has advantages; however, caution is required since the definition of IU varies according to the test and reagents used. It is therefore essential that the conditions and limits for a positive reaction be carefully defined in each case, especially for commercially available kits. PMID:8829878

  16. Validation of a Microsphere Immunoassay for Serological Leptospirosis Diagnosis in Human Serum by Comparison to the Current Gold Standard

    PubMed Central

    Wynwood, Sarah J.; Burns, Mary-Anne A.; Graham, Glenn C.; Weier, Steven L.; McKay, David B.; Craig, Scott B.

    2015-01-01

    A microsphere immunoassay (MIA) utilising Luminex xMap technology that is capable of determining leptospirosis IgG and IgM independently was developed. The MIA was validated using 200 human samples submitted for routine leptospirosis serology testing. The traditional microscopic agglutination (MAT) method (now 100 years old) suffers from a significant range of technical problems including a dependence on antisera which is difficult to source and produce, false positive reactions due to auto-agglutination and an inability to differentiate between IgG and IgM antibodies. A comparative validation method of the MIA against the MAT was performed and used to determine the ability of the MIA to detect leptospiral antibodies when compared with the MAT. The assay was able to determine samples in the reactive, equivocal and non-reactive ranges when compared to the MAT and was able to differentiate leptospiral IgG antibodies from leptospiral IgM antibodies. The MIA is more sensitive than the MAT and in true infections was able to detect low levels of antibody in the later stages of the acute phase as well as detect higher levels of IgM antibody earlier in the immune phase of the infection. The relatively low cost, high throughput platform and significantly reduced dependency on large volumes of rabbit antisera make this assay worthy of consideration for any microbiological assay that currently uses agglutination assays. PMID:25807009

  17. [Diagnosis of human brucellosis. Role of pH in the seroagglutination test and influence of pH on the agglutinating activity of IgM, IgG and IgA antibodies].

    PubMed

    Rubio Vallejo, Manuel; del Pozo, José L; Del Pozo León, José Luis; Hernández-Molina, Juan Manuel; Dorronsoro Ibero, Inés; Marrodán Ciordia, Teresa; Díaz García, Ramón

    2002-04-01

    To evaluate the role of pH in the seroagglutination test (SAT)and Rose Bengal (RB) test, and to determine the influence of pH on the agglutinating activity of IgM, IgG and IgA antibodies. The SAT was performed at pH 7.2 or pH 5.0 in standard microtiter-type polystyrene plates using Ring Test antigen or the Brucella suspension (BRUCAPT) provided in the Brucellacapt kits. Specific antibodies against native hapten were determined by radial immunodiffusion. Additionally, IgG, IgA and IgM fractions were separated from 8 sera by absorption chromatography and their agglutinating capacity was studied at pH 7.2 and 5.0. We studied 72 sera from patients with clinical brucellosis taken at the time of hospitalization, 16 from persons in contact with infected animals, and 16 from healthy donors. SAT results at pH 5.0 correlated with those obtained with the Rose Bengal test. Four Rose Bengal-positive sera were found to be SAT-negative at pH 7.2 and SAT-positive at pH 5.0. SAT performed at pH 5.0 with BRUCAPT antigen yielded higher titers than tests performed at pH 7.2 or 5.0 with Ring Test antigen (p < 0.001), with highest titers in IDR-positive sera. Among the 8 IgG fractions, all but one agglutinated at pH 7.2, and in 4, IgG titers showed significant increases at pH 5.0. Three IgA fractions were SAT-negative at pH 7.2 and SAT-positive at pH 5.0; the other 5 agglutinated at both pH conditions and were DTT-sensitive. All IgA fractions but one were positive by Rose Bengal. Agglutinating activity of the IgM fraction was not affected by pH. The SAT performed with the buffer and antigen suspension included in the Brucellacapt kit (pH 5.0) is highly useful for detecting agglutinating and non-agglutinating antibodies at pH 7.2.

  18. Trajectory control method of stratospheric airship based on the sliding mode control and prediction in wind field

    NASA Astrophysics Data System (ADS)

    Zhang, Jia-shi; Yang, Xi-xiang

    2017-11-01

    The stratospheric airship has the characteristics of large inertia, long time delay and large disturbance of wind field , so the trajectory control is very difficult .Build the lateral three degrees of freedom dynamic model which consider the wind interference , the dynamics equation is linearized by the small perturbation theory, propose a trajectory control method Combine with the sliding mode control and prediction, design the trajectory controller , takes the HAA airship as the reference to carry out simulation analysis. Results show that the improved sliding mode control with front-feedback method not only can solve well control problems of airship trajectory in wind field, but also can effectively improve the control accuracy of the traditional sliding mode control method, solved problems that using the traditional sliding mode control to control. It provides a useful reference for dynamic modeling and trajectory control of stratospheric airship.

  19. Standardization of whole slide image morphologic assessment with definition of a new application: Digital slide dynamic morphometry.

    PubMed

    Puppa, Giacomo; Risio, Mauro; Sheahan, Kieran; Vieth, Michael; Zlobec, Inti; Lugli, Alessandro; Pecori, Sara; Wang, Lai Mun; Langner, Cord; Mitomi, Hiroyuki; Nakamura, Takatoshi; Watanabe, Masahiko; Ueno, Hideki; Chasle, Jacques; Senore, Carlo; Conley, Stephen A; Herlin, Paulette; Lauwers, Gregory Y

    2011-01-01

    In histopathology, the quantitative assessment of various morphologic features is based on methods originally conceived on specific areas observed through the microscope used. Failure to reproduce the same reference field of view using a different microscope will change the score assessed. Visualization of a digital slide on a screen through a dedicated viewer allows selection of the magnification. However, the field of view is rectangular, unlike the circular field of optical microscopy. In addition, the size of the selected area is not evident, and must be calculated. A digital slide morphometric system was conceived to reproduce the various methods published for assessing tumor budding in colorectal cancer. Eighteen international experts in colorectal cancer were invited to participate in a web-based study by assessing tumor budding with five different methods in 100 digital slides. The specific areas to be tested by each method were marked by colored circles. The areas were grouped in a target-like pattern and then saved as an .xml file. When a digital slide was opened, the .xml file was imported in order to perform the measurements. Since the morphometric tool is composed of layers that can be freely moved on top of the digital slide, the technique was named digital slide dynamic morphometry. Twelve investigators completed the task, the majority of them performing the multiple evaluations of each of the cases in less than 12 minutes. Digital slide dynamic morphometry has various potential applications and might be a useful tool for the assessment of histologic parameters originally conceived for optical microscopy that need to be quantified.

  20. A review of Brucella seroprevalence among humans and animals in Bangladesh with special emphasis on epidemiology, risk factors and control opportunities.

    PubMed

    Islam, Md Ariful; Khatun, Mst Minara; Werre, Stephen R; Sriranganathan, Nammalwar; Boyle, Stephen M

    2013-10-25

    Brucellosis is a neglected bacterial zoonotic disease in many countries affecting both humans and animals. The aim of this paper is to review published reports of the seroprevalence of brucellosis in humans and animals (cattle, buffalo, sheep, goats and dogs) in Bangladesh. The prevalence studies are based primarily on the following serological tests: rose bengal plate agglutination test (RBT), plate agglutination test (PAT), tube agglutination test (TAT), mercaptoethanol agglutination test (MET), standard tube agglutination test (STAT), slow agglutination test (SAT), milk ring test (MRT), indirect enzyme-linked immunosorbant assay (I-ELISA), competitive ELISA (C-ELISA) and fluorescent polarization assay (FPA). Seroprevalences of brucellosis were found to be affected by the sensitivity and specificity of serological tests employed. Brucellosis prevalence varied based on occupations of people (2.5-18.6%) and species of animals (3.7% in cattle, 4.0% in buffalo, 3.6% in goats and 7.3% in sheep). The prevalence of brucellosis in humans was reported in livestock farmers (2.6-21.6%), milkers (18.6%), butchers (2.5%) and veterinarians (5.3-11.1%) who have direct contact with animal and its products or who consume raw milk. According to published reports brucellosis does affect people and livestock of Bangladesh. There is an immediate need for a concerted effort to control and eradicate brucellosis from domesticated animals in Bangladesh. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Seroprevalence of Helicobacter pylori in dyspeptic patients and its relationship with HIV infection, ABO blood groups and life style in a university hospital, Northwest Ethiopia

    PubMed Central

    Moges, Feleke; Kassu, Afework; Mengistu, Getahun; Adugna, Solomon; Andualem, Berhanu; Nishikawa, Takeshi; Ota, Fusao

    2006-01-01

    AIM: To determine the prevalence of Helicobacter pylori (H pylori) among dyspeptic patients and to assess the relationship between H pylori infection, blood group, HIV infection and life style of the patients. METHODS: In a hospital-based cross-sectional study, patients attending Outpatient Department of University of Gondar Hospital were enrolled. Socio-demographic information was collected using questionnaires. Serum was analyzed for anti-H pylori IgG antibodies using a commercial kit. HIV serostatus was determined by enzyme-linked immunosorbent assay (ELISA). Blood grouping was performed by slide agglutination tests. RESULTS: A total of 215 dyspeptic patients were included in the study. One hundred and sixteen patients (54%) were females and 99 (46%) were males. Anti-H pylori IgG antibodies were detected in sera of 184 (85.6%) patients. The prevalence was significantly higher in patients aged 50 years and above. Twenty point five percent of the patients were found to be seropositive for HIV. No significant association was found between sex, ABO blood groups, consumption of spicy diets, socio-economic status and seropositivity for H pylori. However, alcohol consumption was significantly associated with H pylori serology. CONCLUSION: The prevalence of H pylori infection is associated with a history of alcohol intake and older age. The effect of different diet, alcohol and socioeconomic status as risk factors for H pylori infection needs further study. PMID:16610007

  2. Automated single-slide staining device

    NASA Technical Reports Server (NTRS)

    Wilkins, J. R.; Mills, S. M. (Inventor)

    1977-01-01

    A simple apparatus and method is disclosed for making individual single Gram stains on bacteria inoculated slides to assist in classifying bacteria in the laboratory as Gram-positive or Gram-negative. The apparatus involves positioning a single inoculated slide in a stationary position and thereafter automatically and sequentially flooding the slide with increments of a primary stain, a mordant, a decolorizer, a counterstain and a wash solution in a sequential manner without the individual lab technician touching the slide and with minimum danger of contamination thereof from other slides.

  3. Genetic and mechanistic evaluation for the weak A phenotype in Ael blood type with IVS6 + 5G>A ABO gene mutation.

    PubMed

    Chen, D-P; Sun, C-F; Ning, H-C; Peng, C-T; Wang, W-T; Tseng, C-P

    2015-01-01

    Ael is a rare blood type that is characterized by weak agglutination of RBCs when reacts with anti-A antibody in adsorption-elution test. Although IVS6 + 5G→A mutation is known to associate with the Ael blood type, genetic and mechanistic evaluation for the weak agglutination of Ael with IVS6 + 5G→A mutation has not yet been completely addressed. In this study, five cases of confirmed Ael individuals were analysed. The cDNAs for the A(el) alleles were obtained by cloning method for sequence analyses. The erythroleukemia K562 cells were used as the cell study model and were transfected with the A(el) expression construct. Flow cytometry analysis was then performed to determine the levels of surface antigen expression. The results indicated that IVS6 + 5G→A attributes to all cases of Ael . RT-PCR analyses revealed the presence of at least 10 types of aberrant A(el) splicing transcripts. Most of the transcripts caused early termination and produced non-functional protein during translation. Nevertheless, the transcript without exons 5-6 was predicted to generate functional Ael glycosyltransferase lacking 57 amino acids at the N-terminal segment. When the exons 5-6 deletion transcript was stably expressed in the K562 cells, weak agglutination of the cells can be induced by adding anti-A antibody followed by adsorption-elution test. This study demonstrates that aberrant splicing of A transcripts contributes to weak A expression and the weak agglutination of Ael -RBCs, adding to the complexity for the regulatory mechanisms of ABO gene expression. © 2014 International Society of Blood Transfusion.

  4. Bioactive extracts of red seaweeds Pterocladiella capillacea and Osmundaria obtusiloba (Floridophyceae: Rhodophyta) with antioxidant and bacterial agglutination potential.

    PubMed

    de Alencar, Daniel Barroso; de Carvalho, Fátima Cristiane Teles; Rebouças, Rosa Helena; Dos Santos, Daniel Rodrigues; Dos Santos Pires-Cavalcante, Kelma Maria; de Lima, Rebeca Larangeira; Baracho, Bárbara Mendes; Bezerra, Rayssa Mendes; Viana, Francisco Arnaldo; Dos Fernandes Vieira, Regine Helena Silva; Sampaio, Alexandre Holanda; de Sousa, Oscarina Viana; Saker-Sampaio, Silvana

    2016-04-01

    To evaluate the antioxidant, antibacterial and bacterial cell agglutination activities of the hexane (Hex) and 70% ethanol (70% EtOH) extracts of two species of red seaweeds Pterocladiella capillacea (P. capillacea) and Osmundaria obtusiloba. In vitro antioxidant activity was determined by DPPH radical scavenging assay, ferric-reducing antioxidant power assay, ferrous ion chelating assay, β-carotene bleaching assay and total phenolic content quantification. Antimicrobial activity was tested using the method of disc diffusion on Mueller-Hinton medium. The ability of algal extracts to agglutinate bacterial cells was also tested. The 70% EtOH extract of the two algae showed the highest values of total phenolic content compared to the Hex extract. The results of DPPH for both extracts (Hex, 70% EtOH) of Osmundaria obtusiloba (43.46% and 99.47%) were higher than those of P. capillacea (33.04% and 40.81%) at a concentration of 1000 μg/mL. As for the ferrous ion chelating, there was an opposite behavior, extracts of P. capillacea had a higher activity. The extracts showed a low ferric-reducing antioxidant power, with optical density ranging from 0.054 to 0.180. Antioxidant activities of all extracts evaluated for β-carotene bleaching were above 40%. There was no antibacterial activity against bacterial strains tested. However, the extracts of both species were able to agglutinate bacterial Gram positive cells of Staphylococcus aureus and Gram negative cells of Escherichia coli, multidrug-resistant Salmonella and Vibrio harveyi. This is the first report of the interaction between these algal extracts, rich in natural compounds with antioxidant potential, and Gram positive and Gram negative bacterial cells. Copyright © 2016 Hainan Medical College. Production and hosting by Elsevier B.V. All rights reserved.

  5. A Low-Wear Driving Method of Ultrasonic Motors

    NASA Astrophysics Data System (ADS)

    Ishii, Takaaki; Takahashi, Hisanori; KentaroNakamura, KentaroNakamura; Ueha, Sadayuki

    1999-05-01

    The life of ultrasonic motors is limited by the wear of friction materials used for the contact surfaces. In order to reduce the wear of the friction material, we have to reduce the sliding speed between the sliding surfaces of the motor. In this report, we propose a new driving method to reduce the sliding speed of the motor by shaping the vibration speed waveform. The sliding loss was calculated and wear reduction effect was confirmed. A wear test was carried out under no-load condition. This method prolongs the life of an ultrasonic motor by about 3.4-fold. The results and wear reduction effects are also described.

  6. Soybean extracts facilitate bacterial agglutination and prevent biofilm formation on orthodontic wire.

    PubMed

    Lee, Heon-Jin; Kwon, Tae-Yub; Kim, Kyo-Han; Hong, Su-Hyung

    2014-01-01

    Soybean is an essential food ingredient that contains a class of organic compounds known as isoflavones. It is also well known that several plant agglutinins interfere with bacterial adherence to smooth surfaces. However, little is known about the effects of soybean extracts or genistein (a purified isoflavone from soybean) on bacterial biofilm formation. We evaluated the effects of soybean (Glycine max) extracts, including fermented soybean and genistein, on streptococcal agglutination and attachment onto stainless steel orthodontic wire. After cultivating streptococci in biofilm medium containing soybean extracts and orthodontic wire, the viable bacteria attached to the wire were counted. Phase-contrast microscopy and scanning electron microscopy (SEM) analyses were conducted to evaluate bacterial agglutination and attachment. Our study showed that soybean extracts induce agglutination between streptococci, which results in bacterial precipitation. Conversely, viable bacterial counting and SEM image analysis of Streptococcus mutans attached to the orthodontic wire show that bacterial attachment decreases significantly when soybean extracts were added. However, there was no significant change in pre-attached S. mutans biofilm in response to soybean. A possible explanation for these results is that increased agglutination of planktonic streptococci by soybean extracts results in inhibition of bacterial attachment onto the orthodontic wire.

  7. Comparison of mounting methods for the evaluation of fibers by phase contrast microscopy.

    PubMed

    Lee, Eun Gyung; Pang, Thomas W S; Nelson, John; Andrew, Mike; Harper, Martin

    2011-07-01

    The objectives of this study were to evaluate mounting methods for fiber examination of air sample filters by phase contrast microscopy (PCM) and to evaluate differences in fiber counts that might be due to fiber movement. Acetone/triacetin (AT) with various amounts of triacetin and acetone/Euparal (AE) where the mounting medium was placed between the cleared filter wedge and the coverslip were tested as a function of time. Field sample slides collected from a taconite iron-ore processing mill, a tremolitic talc-ore processing mill, and from around a crusher in a meta-basalt stone quarry were prepared with relocatable coverslips to revisit the same field areas on the slides. For each slide, three or four field areas were randomly selected and pictures were taken every 2 weeks to determine any sign of fiber movement over time. For 11 AT slides (named as AT-3.5) prepared with 3.5 μl of the mounting medium according to the NIOSH 7400 method, no fiber movements were detected over 59 weeks. On the other hand, AT slides prepared with larger quantities (10, 15, and 20 μl) of the mounting medium (named as AT-10) and AE slides prepared with ∼10 μl mounting medium showed fiber movement from the eighth day at the earliest. Fiber movement began earlier for the slides mounted with excess triacetin than for those mounted with Euparal. The sample slide storage method, either vertically or horizontally, did not seem to accelerate fiber movement. Additionally, two other modified methods, dimethylformamide solution/Euparal (mDE) and dimethylformamide solution/triacetin (mDT), were also prepared where the mounting medium was placed between the cleared filter wedge and the glass slide. The findings of fiber movements were similar; when 3.5 μl of triacetin was used for the mDT slides, fiber movements were not detected, while fibers on slides prepared with 10 μl triacetin (mDT-10) moved around. No fiber movements were observed for the mDE slides at any time during 59 weeks. Once fiber movement started, fibers moved over distances measured from 4 μm and up to >1000 μm within 22 weeks. However, since then, no further fiber movements have been observed in any field sample slides. Additional sample slides, two Amosite and two chrysotile, were prepared from Union for International Cancer Control (UICC) samples using the AT method with 5 μl triacetin mounting medium. Fiber movements were also observed in these samples; chrysotile fibers began to migrate in 3 weeks, while Amosite fiber movement started after 3 months. Although fiber movement was observed for the AT-10, AE, and mDT-10 sample slides, fiber counts were not significantly different from AT-3.5 and mDE samples that exhibited no fiber movement. Although fiber counts would not be significantly changed by fiber movement, the type and amount of mounting medium for sample slide preparation remains critical for issues such as quality assurance and training of analysts by revisiting the same fibers.

  8. Methods for processing and imaging marsh foraminifera

    USGS Publications Warehouse

    Dreher, Chandra A.; Flocks, James G.

    2011-01-01

    This study is part of a larger U.S. Geological Survey (USGS) project to characterize the physical conditions of wetlands in southwestern Louisiana. Within these wetlands, groups of benthic foraminifera-shelled amoeboid protists living near or on the sea floor-can be used as agents to measure land subsidence, relative sea-level rise, and storm impact. In the Mississippi River Delta region, intertidal-marsh foraminiferal assemblages and biofacies were established in studies that pre-date the 1970s, with a very limited number of more recent studies. This fact sheet outlines this project's improved methods, handling, and modified preparations for the use of Scanning Electron Microscope (SEM) imaging of these foraminifera. The objective is to identify marsh foraminifera to the taxonomic species level by using improved processing methods and SEM imaging for morphological characterization in order to evaluate changes in distribution and frequency relative to other environmental variables. The majority of benthic marsh foraminifera consists of agglutinated forms, which can be more delicate than porcelaneous forms. Agglutinated tests (shells) are made of particles such as sand grains or silt and clay material, whereas porcelaneous tests consist of calcite.

  9. 9 CFR 147.7 - Standard test procedures for mycoplasma. 5

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... plate agglutination test, the tube agglutination test, and the enzyme-linked immunosorbent assay (ELISA... accurate however, and are useful in evaluating serum samples that react with the ELISA, plate, and/or tube...

  10. 9 CFR 147.7 - Standard test procedures for mycoplasma. 5

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... plate agglutination test, the tube agglutination test, and the enzyme-linked immunosorbent assay (ELISA... accurate however, and are useful in evaluating serum samples that react with the ELISA, plate, and/or tube...

  11. 9 CFR 147.7 - Standard test procedures for mycoplasma. 5

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... plate agglutination test, the tube agglutination test, and the enzyme-linked immunosorbent assay (ELISA... accurate however, and are useful in evaluating serum samples that react with the ELISA, plate, and/or tube...

  12. 9 CFR 147.6 - Procedure for determining the status of flocks reacting to tests for Mycoplasma gallisepticum...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... agglutination test, enzyme-labeled immunosorbent assay (ELISA), official molecular examination procedure, or... the tube agglutination, ELISA, or serum plate test is positive, the hemaglutination inhibition (HI...

  13. 9 CFR 147.6 - Procedure for determining the status of flocks reacting to tests for Mycoplasma gallisepticum...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... agglutination test, enzyme-labeled immunosorbent assay (ELISA), official molecular examination procedure, or... the tube agglutination, ELISA, or serum plate test is positive, the hemaglutination inhibition (HI...

  14. 9 CFR 147.7 - Standard test procedures for mycoplasma. 5

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... plate agglutination test, the tube agglutination test, and the enzyme-linked immunosorbent assay (ELISA... accurate however, and are useful in evaluating serum samples that react with the ELISA, plate, and/or tube...

  15. 9 CFR 147.6 - Procedure for determining the status of flocks reacting to tests for Mycoplasma gallisepticum...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... agglutination test, enzyme-labeled immunosorbent assay (ELISA), official molecular examination procedure, or... the tube agglutination, ELISA, or serum plate test is positive, the hemaglutination inhibition (HI...

  16. 9 CFR 147.7 - Standard test procedures for mycoplasma. 5

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... plate agglutination test, the tube agglutination test, and the enzyme-linked immunosorbent assay (ELISA... accurate however, and are useful in evaluating serum samples that react with the ELISA, plate, and/or tube...

  17. Student perceptions of digital versus traditional slide use in undergraduate education.

    PubMed

    Solberg, Brooke L

    2012-01-01

    Digitized slides provide a number of intriguing benefits for educators. Before their implementation, however, educators should consider student opinion related to their use. This mixed-methods study directly compared Medical Laboratory Science (MLS) student perceptions of learning experiences in both digital and traditional slide laboratory settings. Results suggested that the majority of students preferred learning with digital slides, and numerous reasons for this preference were identified. Survey responses indicated that students using digital slides tended to view their performances, instructor feedback, and their learning environment more positively than students using traditional slides. Apprehensions about digital slide use were also detected from students preferring traditional slides. These findings provide a guide on how best to exploit both digital and traditional slides in an educational setting.

  18. Research on Synthetic Aperture Radar Processing for the Spaceborne Sliding Spotlight Mode.

    PubMed

    Shen, Shijian; Nie, Xin; Zhang, Xinggan

    2018-02-03

    Gaofen-3 (GF-3) is China' first C-band multi-polarization synthetic aperture radar (SAR) satellite, which also provides the sliding spotlight mode for the first time. Sliding-spotlight mode is a novel mode to realize imaging with not only high resolution, but also wide swath. Several key technologies for sliding spotlight mode in spaceborne SAR with high resolution are investigated in this paper, mainly including the imaging parameters, the methods of velocity estimation and ambiguity elimination, and the imaging algorithms. Based on the chosen Convolution BackProjection (CBP) and PFA (Polar Format Algorithm) imaging algorithms, a fast implementation method of CBP and a modified PFA method suitable for sliding spotlight mode are proposed, and the processing flows are derived in detail. Finally, the algorithms are validated by simulations and measured data.

  19. Second order sliding mode control for a quadrotor UAV.

    PubMed

    Zheng, En-Hui; Xiong, Jing-Jing; Luo, Ji-Liang

    2014-07-01

    A method based on second order sliding mode control (2-SMC) is proposed to design controllers for a small quadrotor UAV. For the switching sliding manifold design, the selection of the coefficients of the switching sliding manifold is in general a sophisticated issue because the coefficients are nonlinear. In this work, in order to perform the position and attitude tracking control of the quadrotor perfectly, the dynamical model of the quadrotor is divided into two subsystems, i.e., a fully actuated subsystem and an underactuated subsystem. For the former, a sliding manifold is defined by combining the position and velocity tracking errors of one state variable, i.e., the sliding manifold has two coefficients. For the latter, a sliding manifold is constructed via a linear combination of position and velocity tracking errors of two state variables, i.e., the sliding manifold has four coefficients. In order to further obtain the nonlinear coefficients of the sliding manifold, Hurwitz stability analysis is used to the solving process. In addition, the flight controllers are derived by using Lyapunov theory, which guarantees that all system state trajectories reach and stay on the sliding surfaces. Extensive simulation results are given to illustrate the effectiveness of the proposed control method. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  20. A technigue exploitation about anti-slide tire polyploid on ice-snow road in winter

    NASA Astrophysics Data System (ADS)

    Xiaojie, Qi; Qiang, Wang; Zhao, Yang; Yunlong, Wang; Guotian, Wang; Degang, Lv

    2017-04-01

    Present studies focus on improving anti-slide property of tyes on ice-snow road by changing material modification of tyre tread and designing groove. However, the basic reason causing starting slide, long braking distance, turning slide slip and so on of tyres used in winter is that tyre tread materials are unitary and homogenous rubber composite which can’t coordinate driving demands of tyres in winter under muti-work condition, and can’t exert their best property when starting, braking and sliding slip. In order to improve comprehensive anti-slide property of tyres, this paper discusses about changing structure, shape and distribution proportion among haploid materials of tyre tread rubber. Polyploid bubber tyre tread technique based on artificial neural network which is in favor of starting, braking and anti-slide slip is optimized and combined. Friction feature and anti-slide mechanism on ice-snow road of polyploid rubber tyre tread are studied using testing technique of low-temperature cabin and computer simulation. A set high anti-slide theories and realizing method systems of polyploid rubber composite formed from basic theory, models and technique method are developped which will be applied into solving anti-slide problem of winter tyres, provide theory instruction for studies on high anti-slide winter tyres, and promote development of application and usage safety of winter tyres.

  1. Evolution of Shock Melt Compositions in Lunar Agglutinates

    NASA Technical Reports Server (NTRS)

    Vance, A. M.; Christoffersen, R.; Keller, L. P.

    2015-01-01

    Lunar agglutinates are aggregates of regolith grains fused together in a glassy matrix of shock melt produced during smaller-scale (mostly micrometeorite) impacts. Agglutinate formation is a key space weathering process under which the optically-active component of nanophase metallic Fe (npFe(sup 0)) is added to the lunar regolith. Here we have used energy-dispersive X-ray (EDX) compositional spectrum imaging in the SEM to quantify the chemical homogeneity of agglutinitic glass, correlate its homogeneity to its parent soil maturity, and identify the principle chemical components contributing to the shock melt compositional variations.

  2. Evaluating the visibility of presentation slides

    NASA Astrophysics Data System (ADS)

    Sugawara, Genki; Umezu, Nobuyuki

    2017-03-01

    Presentations using slide software such as PowerPoint are widely performed in offices and schools. The improvement of presentation skills among ordinary people is required because these days such an opportunity of giving presentation is becoming so common. One of the key factors for making successful presentation is the visibility of the slides, as well as the contents themselves. We propose an algorithm to numerically evaluate the visibility of presentation slides. Our method receives a presentation as a set of images and eliminates the background from the slides to extract characters and figures. This algorithm then evaluates the visibility according to the number and size of characters, their colors, and figure layouts. The slide evaluation criteria are based on the series of experiments with 20 participants to parameterize typical values for visual elements in slides. The algorithm is implemented on an iMac and takes 0.5 sec. to evaluate a slide image. The evaluation score is given as a value between 0 and 100 and the users can improve their slide pages with lower scores. Our future work includes a series of experiments with various presentations and extending our method to publish as a web-based rating service for learning presentation skills.

  3. Terminal Sliding Mode Tracking Controller Design for Automatic Guided Vehicle

    NASA Astrophysics Data System (ADS)

    Chen, Hongbin

    2018-03-01

    Based on sliding mode variable structure control theory, the path tracking problem of automatic guided vehicle is studied, proposed a controller design method based on the terminal sliding mode. First of all, through analyzing the characteristics of the automatic guided vehicle movement, the kinematics model is presented. Then to improve the traditional expression of terminal sliding mode, design a nonlinear sliding mode which the convergence speed is faster than the former, verified by theoretical analysis, the design of sliding mode is steady and fast convergence in the limited time. Finally combining Lyapunov method to design the tracking control law of automatic guided vehicle, the controller can make the automatic guided vehicle track the desired trajectory in the global sense as well as in finite time. The simulation results verify the correctness and effectiveness of the control law.

  4. Roughened glass slides and a spectrophotometer for the detection of the wavelength-dependent refractive index of transparent liquids.

    PubMed

    Niskanen, Ilpo; Räty, Jukka; Myllylä, Risto; Sutinen, Veijo; Matsuda, Kiyofumi; Homma, Kazuhiro; Silfsten, Pertti; Peiponen, Kai-Erik

    2012-07-01

    We describe a method to determine the wavelength-dependent refractive index of liquids by measurement of light transmittance with a spectrophotometer. The method is based on using roughened glass slides with different a priori known refractive indices and immersing the slides into the transparent liquid with unknown refractive index. Using the dispersion data on the glass material it is possible to find the index match between the liquid and the glass slide, and hence the refractive index of the liquid.

  5. Volatile element depletion and K-39/K-41 fractionation in lunar soils

    NASA Technical Reports Server (NTRS)

    Church, S. E.; Tilton, G. R.; Wright, J. E.; Lee-Hu, C.-N.

    1976-01-01

    Evidence for selective loss and isotopic fractionation (in the case of K) of volatile elements during formation of agglutinates by micrometeoritic bombardment of lunar soils is presented. Concentrations and isotopic compositions of volatile elements (K, Rb, Pb) and nonvolatile elements (U, Th, Ba, Sr, rare earths) in separates taken from soils 14163, 14259, 15041, 68501, and 71500 are examined. Rayleigh fractionation calculations applied to K-39/K-41 isotopic data indicate ten-fold recycling of bulk soil, to account for observed isotopic anomalies. The lunar soil fines fraction seems to be a site of deposition for volatile or labile Pb produced during agglutination. Local fines (below 75 microns) are viewed as representative of the parent material for agglutinates formed in situ by micrometeoritic impact. Magnetic separation of agglutinates from soil 68501 revealed a bimodal population, with one class comprising welded blocky magnetic glasses.

  6. Hybridoma cell agglutination as a novel test to detect circulating antigen of Schistosoma japonicum.

    PubMed

    Li, Yong-Long; Liu, Wenqi; Ruppel, Andreas

    2003-01-01

    We developed a serodiagnostic test which is based on the agglutination of hybridoma cells. In the presence of specific antigen, agglutination of the fixed and stained cells occurs and can be visualized in analogy to traditional erythrocyte agglutination. The procedures were developed with a murine cell line producing a monoclonal antibody against a schistosome gut protein and sera of patients and mice infected with Schistosoma japonicum. This test is capable of detecting circulating antigen during pre-patency in mice infected with 50 cercariae. Its sensitivity was high with acute schistosomiasis japonica (97%, n = 32) and moderate with chronic cases (75%, n = 57). No positive reactions were obtained with healthy persons (n = 78) or patients infected with other parasites (Chlonorchis sinensis, n = 20; Paragonimus westermani, n = 20; Plasmodium vivax, n = 10) or suffering from lupus erythomatodus (n = 5) or mononucleosis (n = 10).

  7. The specificity of Centruroides sculpturatus Ewing (Arizona lethal scorpion) hemolymph agglutinins.

    PubMed

    Vasta, G R; Cohen, E

    1982-01-01

    C. sculpturatus sera agglutinate human erythrocytes independently of the ABO blood group, enzyme treatment, incubation temperature or sex of the scorpions. Tested with human lymphocytes and reptile and bird erythrocytes, C. sculpturatus serum reacts like an anti-sialic acid agglutinin. With leukemic lymphocytes, titers are higher than with normal lymphocytes. Mammalian erythrocytes show characteristic agglutination patterns for C. sculpturatus for Limulus polyphemus (horseshoe crab) that suggest different receptors for agglutinins of both species. Cross absorption and elution experiments indicate the presence of at least two specific agglutinins in C. sculpturatus serum. Agglutination is inhibited by N-acetylneuraminic acid and N-glycolyneuraminic acid, for all erythrocytes tested. Calcium is required for optimal activity of C. sculpturatus agglutinins. C. sculpturatus agglutinating activity is destroyed at 65% degrees C for 20 minutes. Titers are decreased by 2-mercaptoethanol, and more so after alkylation with iodoacetic acid suggesting that disulfide bonds are present in C. sculpturatus agglutinin molecules.

  8. Simulation of Mechanical Behavior of Agglutinates

    NASA Technical Reports Server (NTRS)

    Nakagawa, Masami; Moon, Tae-Hyun

    2005-01-01

    Due to lack of "real" lunar soil or even lunar simulant, it is difficult to characterize the interaction between lunar soil (or simulant) with different surfaces that are involved in excavation and processing machinery. One unique feature possessed by lunar soil is the agglutinates produced by repeated high-speed micrometeoroid impacts and subsequent pulverization[l and 2]. The large particles are impacted by micrometeoroids [Fig.l] and pulverized to produce finer particles. This process continues until there are no more "large" particles left on the surface of the moon. Due to high impact speed, the impact melting process fuses fines to make agglutinates such as shown in Fig. 2. We will present a series of simulation results and movies will be shown to indicate brittle behavior of each individual agglutinate and also similar compressibility charts shown by Carrier et al. [3]. Fig. 3 shows our preliminary result of the simulated oedometer tests.

  9. Evaluation of the usefulness of six commercial agglutination assays for serologic diagnosis of toxoplasmosis.

    PubMed

    Villard, Odile; Cimon, Bernard; Franck, Jacqueline; Fricker-Hidalgo, Hélène; Godineau, Nadine; Houze, Sandrine; Paris, Luc; Pelloux, Hervé; Villena, Isabelle; Candolfi, Ermanno

    2012-07-01

    Six agglutination tests for detecting Toxoplasma gondii-specific antibodies (immunoglobulin G or M) in serum were performed and compared. In total, 599 sera were examined using direct and indirect agglutination assays. Sensitivity varied from 93.7% to 100% and specificity from 97.1% to 99.2%. In a selected population with interfering diseases, the percentage of false positives ranged from 4.3% to 10.9%. Although an overall agreement of 100% was found for chronic toxoplasmosis, sensitivity for the detection of confirmed acute toxoplasmosis ranged from 86.4% to 97.3%. Regarding the large variability in terms of the performance of the 6 assays, tests based on the hemagglutination principle were found to be better than the other agglutination tests for all the panels evaluated, meaning that they could be used as qualitative or semiquantitative low-cost screening assays. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Monounsaturated fatty acid ether oligomers formed during heating of virgin olive oil show agglutination activity against human red blood cells.

    PubMed

    Patrikios, Ioannis S; Mavromoustakos, Thomas M

    2014-01-29

    The present work focuses on the characterization of molecules formed when virgin olive oil is heated at 130 °C for 24 h open in air, which are found to be strong agglutinins. The hemagglutinating activity of the newly formed molecule isolated from the heated virgin olive oil sample was estimated against human red blood cells (RBCs). Dimers and polymers (high molecular weight molecules) were identified through thin layer chromatography (TLC) of the oil mixture. (1)H and (13)C nuclear magnetic resonance (NMR) and gas chromatography-mass spectroscopy (GC-MS) were the methods used for structural characterization. Among others, oligomerization of at least two monounsaturated fatty acids (FA) by an ether linkage between the hydrocarbon chains is involved. Light microscopy was used to characterize and visualize the agglutination process. Agglutination without fusion or lysis was observed. It was concluded that the heating of virgin olive oil open in air, among other effects, produces oligomerization as well as polymerization of unsaturated FA, possibly of monohydroxy, monounsaturated FA that is associated with strong hemagglutinating activity against human RBCs. The nutritional value and the effects on human health of such oligomers are not discussed in the literature and remain to be investigated.

  11. A simple nucleic acid hybridization/latex agglutination assay for the rapid detection of polymerase chain reaction amplicons.

    PubMed

    Vollenhofer-Schrumpf, Sabine; Buresch, Ronald; Schinkinger, Manfred

    2007-03-01

    We have developed a new method for the detection of nucleic acid hybridization, based on a simple latex agglutination test that can be evaluated by the unaided eye. Nucleic acid, e.g., a polymerase chain reaction (PCR) product, is denatured and incubated with polystyrene beads carrying covalently bound complementary oligonucleotide sequences. Hybridization of the nucleic acids leads to aggregation of the latex particles, thereby verifying the presence of target sequence. The test is performed at room temperature, and results are available within 10 min. As a proof of principle, the hybridization/latex agglutination assay was applied to the detection of purified PCR fragments either specific for Salmonella spp. or a synthetic sequence, and to the detection of Salmonella enterica in artificially contaminated chicken samples. A few nanograms of purified PCR fragments were detectable. In artificially contaminated chicken samples, 3 colony-forming units (cfu)/25 g were detected in one of three replicates, and 30 cfu/25 g were detected in both of two replicates when samples for PCR were taken directly from primary enrichment, demonstrating the practical applicability of this test system. Even multiplex detection might be achievable. This novel kind of assay could be useful for a range of applications where hybridization of nucleic acids, e.g., PCR fragments, is to be detected.

  12. Detection of acute childhood meningitis by PCR, culture and agglutination tests in Tabriz, Iran.

    PubMed

    Ghotaslou, Reza; Farajnia, Safar; Yeganeh, Fatemeh; Abdoli-Oskouei, Shahram; Ahangarzadeh Rezaee, Mohammad; Barzegar, Mohammad

    2012-01-01

    Meningitis is one of the hazardous and life threatening infections and is associated with mortality and morbidity. The aim of this study was to determine etiological agents of childhood bacterial meningitis. The culture, Gram staining, agglutination and PCR assays were used to examine CSF specimens from 277 patients with presumed bacterial meningitis for the occurrence of 4 most common infectious agents consist of N. meningitis, H. influnsae, S. pneumoniae and S. agalactiae between 2008 and 2009 at different wards of the Children Hospital of Tabriz. The mean age of patients was 35 ± 2 (Mean ± SEM) month, (minimum 11 days maximum 14 years), of all cases 59.6% male and 40.4% female. Overall the diagnosis was confirmed with a CSF culture in 11/277 (3.97%), by agglutination test in 14/277 (5.05%). The isolated bacteria included S. pneumoniae 5 cases, H. influnsae 2 cases, N. meningitis 3 cases and P. aeroginusae 1 case. A positive PCR assay allowed us to diagnose bacterial meningitis in 19 patients (6.8%). In the present study, we found PCR to be a useful and sensitive method for the detection of bacterial DNA in the CSF samples from suspected meningitis patients. Furthermore, to maximize management of meningitis cases, a combination of culture and PCR is necessary.

  13. Survey: interpolation methods for whole slide image processing.

    PubMed

    Roszkowiak, L; Korzynska, A; Zak, J; Pijanowska, D; Swiderska-Chadaj, Z; Markiewicz, T

    2017-02-01

    Evaluating whole slide images of histological and cytological samples is used in pathology for diagnostics, grading and prognosis . It is often necessary to rescale whole slide images of a very large size. Image resizing is one of the most common applications of interpolation. We collect the advantages and drawbacks of nine interpolation methods, and as a result of our analysis, we try to select one interpolation method as the preferred solution. To compare the performance of interpolation methods, test images were scaled and then rescaled to the original size using the same algorithm. The modified image was compared to the original image in various aspects. The time needed for calculations and results of quantification performance on modified images were also compared. For evaluation purposes, we used four general test images and 12 specialized biological immunohistochemically stained tissue sample images. The purpose of this survey is to determine which method of interpolation is the best to resize whole slide images, so they can be further processed using quantification methods. As a result, the interpolation method has to be selected depending on the task involving whole slide images. © 2016 The Authors Journal of Microscopy © 2016 Royal Microscopical Society.

  14. Effect of salivary agglutination on oral streptococcal clearance by human polymorphonuclear neutrophil granulocytes

    PubMed Central

    Itzek, Andreas; Chen, Zhiyun; Merritt, Justin; Kreth, Jens

    2016-01-01

    Salivary agglutination is an important host defense mechanism to aggregate oral commensal bacteria as well as invading pathogens. Saliva flow and subsequent swallowing more easily clear aggregated bacteria compared to single cells. Phagocytic clearance of bacteria through polymorphonuclear neutrophil granulocytes also seems to increase to a certain extent with the size of bacterial aggregates. To determine a connection between salivary agglutination and the host innate immune response by phagocytosis, an in vitro agglutination assay was developed reproducing the average size of salivary bacterial aggregates. Using the oral commensal Streptococcus gordonii as a model organism, the effect of salivary agglutination to the phagocytic clearance through polymorphonuclear neutrophil granulocytes was investigated. Here we describe that salivary aggregates of S. gordonii are readily cleared through phagocytosis, while single bacterial cells showed a significant delay in being phagocytosed and killed. Furthermore, prior to phagocytosis the polymorphonuclear neutrophil granulocytes were able to induce a specific de-aggregation, which was dependent on serine protease activity. The herein presented data suggest that salivary agglutination of bacterial cells leads to an ideal size for recognition by polymorphonuclear neutrophil granulocytes. As a first line of defense, these phagocytic cells are able to recognize the aggregates and de-aggregate them via serine proteases to a more manageable size for efficient phagocytosis and subsequent killing in the phagolysosome. This observed mechanism not only prevents the rapid spreading of oral bacterial cells while entering the bloodstream but would also avoid degranulation of involved polymorphonuclear neutrophil granulocytes thus preventing collateral damage to nearby tissue. PMID:27194631

  15. Effect of salivary agglutination on oral streptococcal clearance by human polymorphonuclear neutrophil granulocytes.

    PubMed

    Itzek, A; Chen, Z; Merritt, J; Kreth, J

    2017-06-01

    Salivary agglutination is an important host defense mechanism to aggregate oral commensal bacteria as well as invading pathogens. Saliva flow and subsequent swallowing more easily clear aggregated bacteria compared with single cells. Phagocytic clearance of bacteria through polymorphonuclear neutrophil granulocytes also seems to increase to a certain extent with the size of bacterial aggregates. To determine a connection between salivary agglutination and the host innate immune response by phagocytosis, an in vitro agglutination assay was developed reproducing the average size of salivary bacterial aggregates. Using the oral commensal Streptococcus gordonii as a model organism, the effect of salivary agglutination on phagocytic clearance through polymorphonuclear neutrophil granulocytes was investigated. Here we describe how salivary aggregates of S. gordonii are readily cleared through phagocytosis, whereas single bacterial cells showed a significant delay in being phagocytosed and killed. Furthermore, before phagocytosis the polymorphonuclear neutrophil granulocytes were able to induce a specific de-aggregation, which was dependent on serine protease activity. The data presented suggest that salivary agglutination of bacterial cells leads to an ideal size for recognition by polymorphonuclear neutrophil granulocytes. As a first line of defense, these phagocytic cells are able to recognize the aggregates and de-aggregate them via serine proteases to a more manageable size for efficient phagocytosis and subsequent killing in the phagolysosome. This observed mechanism not only prevents the rapid spreading of oral bacterial cells while entering the bloodstream but would also avoid degranulation of involved polymorphonuclear neutrophil granulocytes, so preventing collateral damage to nearby tissue. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. The Production of Nominal and Verbal Inflection in an Agglutinative Language: Evidence from Hungarian

    PubMed Central

    Peckham, Don; Szanka, Szilvia; Gazso, Dorottya; Lovassy, Noemi; Ullman, Michael T.

    2015-01-01

    The contrast between regular and irregular inflectional morphology has been useful in investigating the functional and neural architecture of language. However, most studies have examined the regular/irregular distinction in non-agglutinative Indo-European languages (primarily English) with relatively simple morphology. Additionally, the majority of research has focused on verbal rather than nominal inflectional morphology. The present study attempts to address these gaps by introducing both plural and past tense production tasks in Hungarian, an agglutinative non-Indo-European language with complex morphology. Here we report results on these tasks from healthy Hungarian native-speaking adults, in whom we examine regular and irregular nominal and verbal inflection in a within-subjects design. Regular and irregular nouns and verbs were stem on frequency, word length, and phonological structure, and both accuracy and response times were acquired. The results revealed that the regular/irregular contrast yields similar patterns in Hungarian, for both nominal and verbal inflection, as in previous studies of non-agglutinative Indo-European languages: the production of irregular inflected forms was both less accurate and slower than of regular forms, both for plural and past-tense inflection. The results replicate and extend previous findings to an agglutinative language with complex morphology. Together with previous studies, the evidence suggests that the regular/irregular distinction yields a basic behavioral pattern that holds across language families and linguistic typologies. Finally, the study sets the stage for further research examining the neurocognitive substrates of regular and irregular morphology in an agglutinative non-Indo-European language. PMID:25769039

  17. Sliding vane geometry turbines

    DOEpatents

    Sun, Harold Huimin; Zhang, Jizhong; Hu, Liangjun; Hanna, Dave R

    2014-12-30

    Various systems and methods are described for a variable geometry turbine. In one example, a turbine nozzle comprises a central axis and a nozzle vane. The nozzle vane includes a stationary vane and a sliding vane. The sliding vane is positioned to slide in a direction substantially tangent to an inner circumference of the turbine nozzle and in contact with the stationary vane.

  18. Dynamic Sliding Analysis of a Gravity Dam with Fluid-Structure-Foundation Interaction Using Finite Elements and Newmark's Sliding Block Analysis

    NASA Astrophysics Data System (ADS)

    Goldgruber, Markus; Shahriari, Shervin; Zenz, Gerald

    2015-11-01

    To reduce the natural hazard risks—due to, e.g., earthquake excitation—seismic safety assessments are carried out. Especially under severe loading, due to maximum credible or the so-called safety evaluation earthquake, critical infrastructure, as these are high dams, must not fail. However, under high loading local failure might be allowed as long as the entire structure does not collapse. Hence, for a dam, the loss of sliding stability during a short time period might be acceptable if the cumulative displacements after an event are below an acceptable value. This performance is not only valid for gravity dams but also for rock blocks as sliding is even more imminent in zones with higher seismic activity. Sliding modes cannot only occur in the dam-foundation contact, but also in sliding planes formed due to geological conditions. This work compares the qualitative possible and critical displacements for two methods, the well-known Newmark's sliding block analysis and a Fluid-Foundation-Structure Interaction simulation with the finite elements method. The results comparison of the maximum displacements at the end of the seismic event of the two methods depicts that for high friction angles, they are fairly close. For low friction angles, the results are differing more. The conclusion is that the commonly used Newmark's sliding block analysis and the finite elements simulation are only comparable for high friction angles, where this factor dominates the behaviour of the structure. Worth to mention is that the proposed simulation methods are also applicable to dynamic rock wedge problems and not only to dams.

  19. Global Sliding Mode Control for the Bank-to-Turn of Hypersonic Glide Vehicle

    NASA Astrophysics Data System (ADS)

    Zhang, J.; Yu, Y. F.; Yan, P. P.; Fan, Y. H.; Guo, X. W.

    2017-03-01

    The technology of Bank-to-Turn has been recognized as an attractive direction due to their significance for the control of hypersonic glide vehicle. Strong coupling existing among pitch, yaw and roll channel was a great challenge for banking to turn, and thus a novel global sliding mode controller was designed for hypersonic glider in this paper. Considering the coupling among channels as interference, we can use invariance principle of sliding mode motion to realize the decoupling control. The global sliding mode control system could eliminate the stage of reaching, which can lead to the realization of whole systematic process decoupling control. When the global sliding mode factor was designed, a minimum norm pole assignment method of the sliding mode matrix was introduced to improve the robustness of the system. The method of continuity of symbolic function was adopted to overcome the chatter, which furtherly modify the transient performance of the system. The simulation results show that this method has good performance of three channel decoupling control and guidance command tracking. And it can meet the requirements of the dynamic performance of the system.

  20. SPH-based numerical simulations of flow slides in municipal solid waste landfills.

    PubMed

    Huang, Yu; Dai, Zili; Zhang, Weijie; Huang, Maosong

    2013-03-01

    Most municipal solid waste (MSW) is disposed of in landfills. Over the past few decades, catastrophic flow slides have occurred in MSW landfills around the world, causing substantial economic damage and occasionally resulting in human victims. It is therefore important to predict the run-out, velocity and depth of such slides in order to provide adequate mitigation and protection measures. To overcome the limitations of traditional numerical methods for modelling flow slides, a mesh-free particle method entitled smoothed particle hydrodynamics (SPH) is introduced in this paper. The Navier-Stokes equations were adopted as the governing equations and a Bingham model was adopted to analyse the relationship between material stress rates and particle motion velocity. The accuracy of the model is assessed using a series of verifications, and then flow slides that occurred in landfills located in Sarajevo and Bandung were simulated to extend its applications. The simulated results match the field data well and highlight the capability of the proposed SPH modelling method to simulate such complex phenomena as flow slides in MSW landfills.

  1. 'Agglutination and flocculation' of stem cells collected by apheresis due to cryofibrinogen.

    PubMed

    Siegenthaler, M A; Vu, D-H; Ebnöther, M; Ketterer, N; Luthi, F; Schmid, P; Bargetzi, M; Gasparini, D; Tissot, J-D

    2004-04-01

    Collection of peripheral stem cells by apheresis is a well-described process. Here, investigations concerning 'agglutination and flocculation' of stem cells collected from two patients are described. In both cases, cryoproteins were observed and cryofibrinogen was identified using high-resolution two-dimensional electrophoresis. In one case, peripheral stem cells were collected after a second course of mobilization, and the cells were immediately washed at 37 degrees C before being frozen, allowing their use, despite the presence of cryofibrinogen. In the other case, 'agglutination' was reversed by warming the bag, and plasma was removed before freezing.

  2. The Rapid Diagnosis of Leptospirosis: A Prospective Comparison of the Dot Enzyme-Linked Immunosorbent Assay and the Genus-Specific Microscopic Agglutination Test at Different Stages of Illness

    DTIC Science & Technology

    1988-04-01

    stages of illness. 12 09RSONAL AU’THORt(S) George WttT4y M . Aiquiza, Laurei P. Padre, Ma. Linda Tuazon, Lar,:y- W. awbi 13s. TYPE OF REPORT I ]b TIME...agglutination test at different stages of illness George Watt, Lily M , Alquiza, Laurena Padre, Ma. Linda Tuazon, and Larry W. Laughlin REPORT NO. TR...MICROSCOPIC AGGLUTINATION TEST AT DIFFERENT STAGES OF ILLNESS GLORGE WATT. LILY M . ALQUIZA, LAURENA P. PADRE. MAR! • LINDA TAUZON, and LARRY W

  3. Development of a blocking latex agglutination test for the detection of antibodies to chicken anemia virus.

    PubMed

    Trinh, Dai Quang; Ogawa, Haruko; Bui, Vuong Nghia; Nguyen, Tham Thi Hong; Gronsang, Dulyatad; Baatartsogt, Tugsbaatar; Kizito, Mugimba Kahoza; AboElkhair, Mohammed; Yamaguchi, Shigeo; Nguyen, Viet Khong; Imai, Kunitoshi

    2015-09-01

    A blocking latex agglutination test (b-LAT) developed in this study was evaluated for the detection of antibodies against chicken anemia virus (CAV) in chickens. Polystyrene latex beads were coupled with a neutralizing monoclonal antibody (mAb) to CAV (mAb-beads). When mAb-beads were mixed with antigens prepared from the lysate of MDCC-MSB1 cells infected with CAV, agglutination occurred. A short pre-incubation of CAV antigens with CAV-specific antiserum inhibited the agglutination of mAb-beads. The test results were obtained within 5min. The specificity of b-LAT was evaluated using sera from specific pathogen-free chickens and sera containing antibodies to avian influenza virus, Newcastle disease virus, infectious bursal disease virus, and Marek's disease virus; nonspecific agglutination and cross-reactivity with antibodies to unrelated viruses were not observed. The examination of 94 serum samples collected from commercial breeder chickens of various ages (17-63 weeks) revealed good agreement (93.6%, Kappa value=0.82) between b-LAT and a virus neutralization test, known to be most sensitive and specific in the detection of antibodies to CAV. These results indicate that b-LAT, a simple and rapid test, is a useful and reliable tool in CAV serology. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Red Blood Cell Agglutination for Blood Typing Within Passive Microfluidic Biochips.

    PubMed

    Huet, Maxime; Cubizolles, Myriam; Buhot, Arnaud

    2018-04-19

    Pre-transfusion bedside compatibility test is mandatory to check that the donor and the recipient present compatible groups before any transfusion is performed. Although blood typing devices are present on the market, they still suffer from various drawbacks, like results that are based on naked-eye observation or difficulties in blood handling and process automation. In this study, we addressed the development of a red blood cells (RBC) agglutination assay for point-of-care blood typing. An injection molded microfluidic chip that is designed to enhance capillary flow contained anti-A or anti-B dried reagents inside its microchannel. The only blood handling step in the assay protocol consisted in the deposit of a blood drop at the tip of the biochip, and imaging was then achieved. The embedded reagents were able to trigger RBC agglutination in situ, allowing for us to monitor in real time the whole process. An image processing algorithm was developed on diluted bloods to compute real-time agglutination indicator and was further validated on undiluted blood. Through this proof of concept, we achieved efficient, automated, real time, and quantitative measurement of agglutination inside a passive biochip for blood typing which could be further generalized to blood biomarker detection and quantification.

  5. A micro-rheological method for determination of blood type.

    PubMed

    Makulska, Sylwia; Jakiela, Slawomir; Garstecki, Piotr

    2013-07-21

    The measurement of time and distance can be used for determining agglutination in small (nL) samples of liquid. We demonstrate the use of this new scheme of detection in typing and subtyping blood in a simple microfluidic system that monitors the speed of flow of microdroplets. The system (i) accepts small samples of liquids deposited directly onto the chip, (ii) forms droplets on demand from these samples, (iii) merges the droplets, and (iv) measures their speed in a microchannel. A sequence of measurements on different combinations of blood and antibodies can thus be used to determine blood type with the estimated probability of mistyping being less than 1 in a million tests. In addition, in the agglutinated samples, red blood cells concentrate at the rear of the droplets yielding an additional vista for detection and suggesting a possible mechanism for separations.

  6. Application of Sliding Mode Methods to the Design of Reconfigurable Flight Control Systems

    NASA Technical Reports Server (NTRS)

    Wells, Scott R.

    2002-01-01

    Observer-based sliding mode control is investigated for application to aircraft reconfigurable flight control. A comprehensive overview of reconfigurable flight control is given, including, a review of the current state-of-the-art within the subdisciplines of fault detection, parameter identification, adaptive control schemes, and dynamic control allocation. Of the adaptive control methods reviewed, sliding mode control (SMC) appears very promising due its property of invariance to matched uncertainty. An overview of sliding mode control is given and its remarkable properties are demonstrated by example. Sliding mode methods, however, are difficult to implement because unmodeled parasitic dynamics cause immediate and severe instability. This presents a challenge for all practical applications with limited bandwidth actuators. One method to deal with parasitic dynamics is the use of an asymptotic observer in the feedback path. Observer-based SMC is investigated, and a method for selecting observer gains is offered. An additional method for shaping the feedback loop using a filter is also developed. It is shown that this SMC prefilter is equivalent to a form of model reference hedging. A complete design procedure is given which takes advantage of the sliding mode boundary layer to recast the SMC as a linear control law. Frequency domain loop shaping is then used to design the sliding manifold. Finally, three aircraft applications are demonstrated. An F-18/HARV is used to demonstrate a SISO pitch rate tracking controller. It is also used to demonstrate a MIMO lateral-directional roll rate tracking controller. The last application is a full linear six degree-of-freedom advanced tailless fighter model. The observer-based SMC is seen to provide excellent tracking with superior robustness to parameter changes and actuator failures.

  7. Application of whole slide image markup and annotation for pathologist knowledge capture

    PubMed Central

    Campbell, Walter S.; Foster, Kirk W.; Hinrichs, Steven H.

    2013-01-01

    Objective: The ability to transfer image markup and annotation data from one scanned image of a slide to a newly acquired image of the same slide within a single vendor platform was investigated. The goal was to study the ability to use image markup and annotation data files as a mechanism to capture and retain pathologist knowledge without retaining the entire whole slide image (WSI) file. Methods: Accepted mathematical principles were investigated as a method to overcome variations in scans of the same glass slide and to accurately associate image markup and annotation data across different WSI of the same glass slide. Trilateration was used to link fixed points within the image and slide to the placement of markups and annotations of the image in a metadata file. Results: Variation in markup and annotation placement between WSI of the same glass slide was reduced from over 80 μ to less than 4 μ in the x-axis and from 17 μ to 6 μ in the y-axis (P < 0.025). Conclusion: This methodology allows for the creation of a highly reproducible image library of histopathology images and interpretations for educational and research use. PMID:23599902

  8. Combination of statistical and physically based methods to assess shallow slide susceptibility at the basin scale

    NASA Astrophysics Data System (ADS)

    Oliveira, Sérgio C.; Zêzere, José L.; Lajas, Sara; Melo, Raquel

    2017-07-01

    Approaches used to assess shallow slide susceptibility at the basin scale are conceptually different depending on the use of statistical or physically based methods. The former are based on the assumption that the same causes are more likely to produce the same effects, whereas the latter are based on the comparison between forces which tend to promote movement along the slope and the counteracting forces that are resistant to motion. Within this general framework, this work tests two hypotheses: (i) although conceptually and methodologically distinct, the statistical and deterministic methods generate similar shallow slide susceptibility results regarding the model's predictive capacity and spatial agreement; and (ii) the combination of shallow slide susceptibility maps obtained with statistical and physically based methods, for the same study area, generate a more reliable susceptibility model for shallow slide occurrence. These hypotheses were tested at a small test site (13.9 km2) located north of Lisbon (Portugal), using a statistical method (the information value method, IV) and a physically based method (the infinite slope method, IS). The landslide susceptibility maps produced with the statistical and deterministic methods were combined into a new landslide susceptibility map. The latter was based on a set of integration rules defined by the cross tabulation of the susceptibility classes of both maps and analysis of the corresponding contingency tables. The results demonstrate a higher predictive capacity of the new shallow slide susceptibility map, which combines the independent results obtained with statistical and physically based models. Moreover, the combination of the two models allowed the identification of areas where the results of the information value and the infinite slope methods are contradictory. Thus, these areas were classified as uncertain and deserve additional investigation at a more detailed scale.

  9. 3D DEM analyses of the 1963 Vajont rock slide

    NASA Astrophysics Data System (ADS)

    Boon, Chia Weng; Houlsby, Guy; Utili, Stefano

    2013-04-01

    The 1963 Vajont rock slide has been modelled using the distinct element method (DEM). The open-source DEM code, YADE (Kozicki & Donzé, 2008), was used together with the contact detection algorithm proposed by Boon et al. (2012). The critical sliding friction angle at the slide surface was sought using a strength reduction approach. A shear-softening contact model was used to model the shear resistance of the clayey layer at the slide surface. The results suggest that the critical sliding friction angle can be conservative if stability analyses are calculated based on the peak friction angles. The water table was assumed to be horizontal and the pore pressure at the clay layer was assumed to be hydrostatic. The influence of reservoir filling was marginal, increasing the sliding friction angle by only 1.6˚. The results of the DEM calculations were found to be sensitive to the orientations of the bedding planes and cross-joints. Finally, the failure mechanism was investigated and arching was found to be present at the bend of the chair-shaped slope. References Boon C.W., Houlsby G.T., Utili S. (2012). A new algorithm for contact detection between convex polygonal and polyhedral particles in the discrete element method. Computers and Geotechnics, vol 44, 73-82, doi.org/10.1016/j.compgeo.2012.03.012. Kozicki, J., & Donzé, F. V. (2008). A new open-source software developed for numerical simulations using discrete modeling methods. Computer Methods in Applied Mechanics and Engineering, 197(49-50), 4429-4443.

  10. Impacts of papain and neuraminidase enzyme treatment on electrohydrodynamics and IgG-mediated agglutination of type A red blood cells.

    PubMed

    Hyono, Atsushi; Gaboriaud, Fabien; Mazda, Toshio; Takata, Youichi; Ohshima, Hiroyuki; Duval, Jérôme F L

    2009-09-15

    The stability of native and enzyme-treated human red blood cells of type A (Rh D positive) against agglutination is investigated under conditions where it is mediated by immunoglobuline G (IgG) anti-D antibody binding. The propensity of cells to agglutinate is related to their interphasic (electrokinetic) properties. These properties significantly depend on the concentration of proteolytic papain enzyme and protease-free neuraminidase enzyme that the cells are exposed to. The analysis is based on the interpretation of electrophoretic data of cells by means of the numerical theory for the electrokinetics of soft (bio)particles. A significant reduction of the hydrodynamic permeability of the external soft glycoprotein layer of the cells is reported under the action of papain. This reflects a significant decrease in soft surface layer thickness and a loss in cell surface integrity/rigidity, as confirmed by nanomechanical AFM analysis. Neuraminidase action leads to an important decrease in the interphase charge density by removing sialic acids from the cell soft surface layer. This is accompanied by hydrodynamic softness modulations less significant than those observed for papain-treated cells. On the basis of these electrohydrodynamic characteristics, the overall interaction potential profiles between two native cells and two enzyme-treated cells are derived as a function of the soft surface layer thickness in the Debye-Hückel limit that is valid for cell suspensions under physiological conditions (approximately 0.16 M). The thermodynamic computation of cell suspension stability against IgG-mediated agglutination then reveals that a decrease in the cell surface layer thickness is more favorable than a decrease in interphase charge density for inducing agglutination. This is experimentally confirmed by agglutination data collected for papain- and neuraminidase-treated cells.

  11. Comparative evaluation of recombinant LigB protein and heat-killed antigen-based latex agglutination test with microscopic agglutination test for diagnosis of bovine leptospirosis.

    PubMed

    Nagalingam, Mohandoss; Thirumalesh, Sushma Rahim Assadi; Kalleshamurthy, Triveni; Niharika, Nakkala; Balamurugan, Vinayagamurthy; Shome, Rajeswari; Sengupta, Pinaki Prasad; Shome, Bibek Ranjan; Prabhudas, Krishnamsetty; Rahman, Habibur

    2015-10-01

    This study aimed to develop latex agglutination test (LAT) using recombinant leptospiral immunoglobulin-like protein (LigB) (rLigB) antigen and compare its diagnostic efficacy with LAT using conventional heat-killed leptospiral antigen and microscopic agglutination test (MAT) in diagnosing bovine leptospirosis. The PCR-amplified 1053-bp ligB gene sequences from Leptospira borgpetersenii Hardjo serovar were cloned in pET 32 (a) vector at EcoRI and NotI sites and expressed in BL21 E. coli cells as fusion protein with thioredoxin (-57 kDa) and characterized by SDS-PAGE and immunoblot. Out of 390 serum samples [cattle (n = 214), buffaloes (n = 176)] subjected to MAT, 115 samples showed reciprocal titre≥100 up to 1600 against one or more serovars. For recombinant LigB protein/antigen-based LAT, agglutination was observed in the positive sample, while no agglutination was observed in the negative sample. Similarly, heat-killed leptospiral antigen was prepared from and used in LAT for comparison with MAT. A two-sided contingency table was used for analysis of LAT using both the antigens separately against MAT for 390 serum samples. The sensitivity, specificity and positive and negative predictive values of recombinant LigB LAT were found to be 75.65, 91.27, 78.38 and 89.96 %, respectively, and that of heat-killed antigen-based LAT were 72.17, 89.82, 74.77 and 88.53 %, respectively, in comparison with MAT. This developed test will be an alternative/complementary to the existing battery of diagnostic assays/tests for specific detection of pathogenic Leptospira infection in bovine population.

  12. Properties of Streptococcus mutans Grown in a Synthetic Medium: Binding of Glucosyltransferase and In Vitro Adherence, and Binding of Dextran/Glucan and Glycoprotein and Agglutination

    PubMed Central

    Wu-Yuan, Christine D.; Tai, Stella; Slade, Hutton D.

    1979-01-01

    The influence of culture media on various properties of Streptococcus mutans was investigated. Strains of S. mutans (serotypes c, d, f, and g) were grown in a complex medium (Todd-Hewitt broth [THB]) or a synthetic medium (SYN). The SYN cells, in contrast to THB cells, did not bind extracellular glucosyltransferase and did not produce in vitro adherence. Both types of cells possessed constitutive levels of glucosyltransferase. B13 cells grown in SYN plus invertase-treated glucose possessed the same level of constitutive enzyme as THB cells. In contrast to THB cells, the SYN cells of seven serotype strains did not agglutinate upon the addition of high-molecular-weight dextran/glucan. Significant quantities of lower-molecular-weight (2 × 104 or 7 × 104) dextran and B13 glucan were bound by SYN cells. SYN cells agglutinated weakly in anti-glucan serum (titers, 0 to 16), whereas THB cells possessed titers of 32 to 256. Evidence for the existence of a second binding site in agglutination which does not possess a glucan-like polymer has been obtained. B13 cells grown in invertase-treated THB agglutinated to the same degree as normal THB cells. The nature of this site is unknown. SYN cells possess the type-specific polysaccharide antigen. B13 cells did not bind from THB a glycoprotein which reacts with antisera to the A, B, or T blood group antigens or which allows agglutination upon the addition of dextran. The results demonstrate that S. mutans grown in a chemically defined medium possesse markedly different biochemical and biological activities than cells grown in a complex organic medium. PMID:457252

  13. How to Prepare Clay-Lift and Sandwich Slides.

    ERIC Educational Resources Information Center

    Barman, Charles R.

    1984-01-01

    Describes two techniques for making 35 millimeter slides without using photographic film. One method uses clear adhesive contact paper and the other uses transparency film. Both techniques are inexpensive and require only a few minutes of preparation per slide. (JM)

  14. Clustering methods applied in the detection of Ki67 hot-spots in whole tumor slide images: an efficient way to characterize heterogeneous tissue-based biomarkers.

    PubMed

    Lopez, Xavier Moles; Debeir, Olivier; Maris, Calliope; Rorive, Sandrine; Roland, Isabelle; Saerens, Marco; Salmon, Isabelle; Decaestecker, Christine

    2012-09-01

    Whole-slide scanners allow the digitization of an entire histological slide at very high resolution. This new acquisition technique opens a wide range of possibilities for addressing challenging image analysis problems, including the identification of tissue-based biomarkers. In this study, we use whole-slide scanner technology for imaging the proliferating activity patterns in tumor slides based on Ki67 immunohistochemistry. Faced with large images, pathologists require tools that can help them identify tumor regions that exhibit high proliferating activity, called "hot-spots" (HSs). Pathologists need tools that can quantitatively characterize these HS patterns. To respond to this clinical need, the present study investigates various clustering methods with the aim of identifying Ki67 HSs in whole tumor slide images. This task requires a method capable of identifying an unknown number of clusters, which may be highly variable in terms of shape, size, and density. We developed a hybrid clustering method, referred to as Seedlink. Compared to manual HS selections by three pathologists, we show that Seedlink provides an efficient way of detecting Ki67 HSs and improves the agreement among pathologists when identifying HSs. Copyright © 2012 International Society for Advancement of Cytometry.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lei, Hongzhuan; Lu, Zhiming; Vesselinov, Velimir Valentinov

    These are slides from a presentation on identifying heterogeneities in subsurface environment using the level set method. The slides start with the motivation, then explain Level Set Method (LSM), the algorithms, some examples are given, and finally future work is explained.

  16. Spatial Normalization of Reverse Phase Protein Array Data

    PubMed Central

    Kaushik, Poorvi; Molinelli, Evan J.; Miller, Martin L.; Wang, Weiqing; Korkut, Anil; Liu, Wenbin; Ju, Zhenlin; Lu, Yiling; Mills, Gordon; Sander, Chris

    2014-01-01

    Reverse phase protein arrays (RPPA) are an efficient, high-throughput, cost-effective method for the quantification of specific proteins in complex biological samples. The quality of RPPA data may be affected by various sources of error. One of these, spatial variation, is caused by uneven exposure of different parts of an RPPA slide to the reagents used in protein detection. We present a method for the determination and correction of systematic spatial variation in RPPA slides using positive control spots printed on each slide. The method uses a simple bi-linear interpolation technique to obtain a surface representing the spatial variation occurring across the dimensions of a slide. This surface is used to calculate correction factors that can normalize the relative protein concentrations of the samples on each slide. The adoption of the method results in increased agreement between technical and biological replicates of various tumor and cell-line derived samples. Further, in data from a study of the melanoma cell-line SKMEL-133, several slides that had previously been rejected because they had a coefficient of variation (CV) greater than 15%, are rescued by reduction of CV below this threshold in each case. The method is implemented in the R statistical programing language. It is compatible with MicroVigene and SuperCurve, packages commonly used in RPPA data analysis. The method is made available, along with suggestions for implementation, at http://bitbucket.org/rppa_preprocess/rppa_preprocess/src. PMID:25501559

  17. A Locally Adaptive Regularization Based on Anisotropic Diffusion for Deformable Image Registration of Sliding Organs

    PubMed Central

    Pace, Danielle F.; Aylward, Stephen R.; Niethammer, Marc

    2014-01-01

    We propose a deformable image registration algorithm that uses anisotropic smoothing for regularization to find correspondences between images of sliding organs. In particular, we apply the method for respiratory motion estimation in longitudinal thoracic and abdominal computed tomography scans. The algorithm uses locally adaptive diffusion tensors to determine the direction and magnitude with which to smooth the components of the displacement field that are normal and tangential to an expected sliding boundary. Validation was performed using synthetic, phantom, and 14 clinical datasets, including the publicly available DIR-Lab dataset. We show that motion discontinuities caused by sliding can be effectively recovered, unlike conventional regularizations that enforce globally smooth motion. In the clinical datasets, target registration error showed improved accuracy for lung landmarks compared to the diffusive regularization. We also present a generalization of our algorithm to other sliding geometries, including sliding tubes (e.g., needles sliding through tissue, or contrast agent flowing through a vessel). Potential clinical applications of this method include longitudinal change detection and radiotherapy for lung or abdominal tumours, especially those near the chest or abdominal wall. PMID:23899632

  18. A locally adaptive regularization based on anisotropic diffusion for deformable image registration of sliding organs.

    PubMed

    Pace, Danielle F; Aylward, Stephen R; Niethammer, Marc

    2013-11-01

    We propose a deformable image registration algorithm that uses anisotropic smoothing for regularization to find correspondences between images of sliding organs. In particular, we apply the method for respiratory motion estimation in longitudinal thoracic and abdominal computed tomography scans. The algorithm uses locally adaptive diffusion tensors to determine the direction and magnitude with which to smooth the components of the displacement field that are normal and tangential to an expected sliding boundary. Validation was performed using synthetic, phantom, and 14 clinical datasets, including the publicly available DIR-Lab dataset. We show that motion discontinuities caused by sliding can be effectively recovered, unlike conventional regularizations that enforce globally smooth motion. In the clinical datasets, target registration error showed improved accuracy for lung landmarks compared to the diffusive regularization. We also present a generalization of our algorithm to other sliding geometries, including sliding tubes (e.g., needles sliding through tissue, or contrast agent flowing through a vessel). Potential clinical applications of this method include longitudinal change detection and radiotherapy for lung or abdominal tumours, especially those near the chest or abdominal wall.

  19. The relationship of the lunar regolith less than 10 micrometer fraction and agglutinates. I - A model for agglutinate formation and some indirect supportive evidence

    NASA Technical Reports Server (NTRS)

    Papike, J. J.; Simon, S. B.; White, C.; Laul, J. C.

    1982-01-01

    The first part of a study of the 'less than 10 micrometer' soil fraction and agglutinates is concerned with the chemical systematics of the considered fraction of lunar soils, taking into account a model for agglutinate formation based on the fusion of the finest fraction (FFF). Attention is given to some evidence which supports the FFF model. The evidence is based on some indirect approaches to an estimation of the composition of the fused soil component. It is found that the 'less than 10 micrometer' soil fraction from all Apollo sites except Apollo 16 (which can be explained) is more feldspathic and enriched in incompatible elements (e.g., K and Th) than the bulk soil. It is concluded that these systematics result from simple comminution in which feldspar breaks down to finer sizes than pyroxene and olivine and the fine-grained incompatible-element-enriched mesostasis concentrates in the 'less than 10 micrometer' soil fraction.

  20. Agglutinates as recorders of fossil soil compositions. [of Apollo 17 lunar probes

    NASA Technical Reports Server (NTRS)

    Taylor, G. J.; Wentworth, S.; Warner, R. D.; Keil, K.

    1978-01-01

    The composition of agglutinates in polished sections of the Apollo 17 drill core was studied in an attempt to deduce the nature of the Taurus-Littrow valley regolith prior to the formation of the Camelot and Central Cluster craters. The agglutinate compositions in the soils differed from the host soil compositions except for samples from the North Massif. Local materials from the valley floor and the massifs appear to form the pre-Central Cluster regolith. It is also shown that chemical mixing models for bulk soil compositions can be misleading unless the petrologic characteristics of each soil are taken into account.

  1. Darkfield Adapter for Whole Slide Imaging: Adapting a Darkfield Internal Reflection Illumination System to Extend WSI Applications

    PubMed Central

    Kawano, Yoshihiro; Higgins, Christopher; Yamamoto, Yasuhito; Nyhus, Julie; Bernard, Amy; Dong, Hong-Wei; Karten, Harvey J.; Schilling, Tobias

    2013-01-01

    We present a new method for whole slide darkfield imaging. Whole Slide Imaging (WSI), also sometimes called virtual slide or virtual microscopy technology, produces images that simultaneously provide high resolution and a wide field of observation that can encompass the entire section, extending far beyond any single field of view. For example, a brain slice can be imaged so that both overall morphology and individual neuronal detail can be seen. We extended the capabilities of traditional whole slide systems and developed a prototype system for darkfield internal reflection illumination (DIRI). Our darkfield system uses an ultra-thin light-emitting diode (LED) light source to illuminate slide specimens from the edge of the slide. We used a new type of side illumination, a variation on the internal reflection method, to illuminate the specimen and create a darkfield image. This system has four main advantages over traditional darkfield: (1) no oil condenser is required for high resolution imaging (2) there is less scatter from dust and dirt on the slide specimen (3) there is less halo, providing a more natural darkfield contrast image, and (4) the motorized system produces darkfield, brightfield and fluorescence images. The WSI method sometimes allows us to image using fewer stains. For instance, diaminobenzidine (DAB) and fluorescent staining are helpful tools for observing protein localization and volume in tissues. However, these methods usually require counter-staining in order to visualize tissue structure, limiting the accuracy of localization of labeled cells within the complex multiple regions of typical neurohistological preparations. Darkfield imaging works on the basis of light scattering from refractive index mismatches in the sample. It is a label-free method of producing contrast in a sample. We propose that adapting darkfield imaging to WSI is very useful, particularly when researchers require additional structural information without the use of further staining. PMID:23520500

  2. Optimal second order sliding mode control for nonlinear uncertain systems.

    PubMed

    Das, Madhulika; Mahanta, Chitralekha

    2014-07-01

    In this paper, a chattering free optimal second order sliding mode control (OSOSMC) method is proposed to stabilize nonlinear systems affected by uncertainties. The nonlinear optimal control strategy is based on the control Lyapunov function (CLF). For ensuring robustness of the optimal controller in the presence of parametric uncertainty and external disturbances, a sliding mode control scheme is realized by combining an integral and a terminal sliding surface. The resulting second order sliding mode can effectively reduce chattering in the control input. Simulation results confirm the supremacy of the proposed optimal second order sliding mode control over some existing sliding mode controllers in controlling nonlinear systems affected by uncertainty. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  3. Sliding mode output feedback control based on tracking error observer with disturbance estimator.

    PubMed

    Xiao, Lingfei; Zhu, Yue

    2014-07-01

    For a class of systems who suffers from disturbances, an original output feedback sliding mode control method is presented based on a novel tracking error observer with disturbance estimator. The mathematical models of the systems are not required to be with high accuracy, and the disturbances can be vanishing or nonvanishing, while the bounds of disturbances are unknown. By constructing a differential sliding surface and employing reaching law approach, a sliding mode controller is obtained. On the basis of an extended disturbance estimator, a creative tracking error observer is produced. By using the observation of tracking error and the estimation of disturbance, the sliding mode controller is implementable. It is proved that the disturbance estimation error and tracking observation error are bounded, the sliding surface is reachable and the closed-loop system is robustly stable. The simulations on a servomotor positioning system and a five-degree-of-freedom active magnetic bearings system verify the effect of the proposed method. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  4. The incomplete anti-Rh antibody agglutination mechanism of trypsinized ORh+ red cells.

    PubMed Central

    Margni, R A; Leoni, J; Bazzurro, M

    1977-01-01

    The capacity for binding to trypsinized and non-trypsinized ORh+ red cells, of the IgG incomplete anti-Rh antibody and its F(ab')2 and Fc fragments has been investigated. An analysis has also been made of the capacity of non-specific human IgG, aggregated non-specific human IgG, human IgM (19S) and IgM (7S), and of fragments Fcgamma, Fcmu and Fc5mu to inhibit the agglutination of trypsinized ORh+ red cells by the IgG incomplete anti-Rh antibody. The results obtained indicate that these antibodies behave in a similar manner to that of nonprecipitating antibodies, and that the agglutination of trypsinized red cells seems to be a mixed reaction due to the interaction of an Fab fragment with its Rh antigenic determinant present in the surface of a red cell and the Fc of the same molecule with a receptor for Fc present in adjacent red cells. The trypsin treatment apparently results in the liberation of occult Fc receptors. It has also been demonstrated that in the agglutination of ORh+ red cells by IgG incomplete anti-Rh antibody in the presence of albumin, interaction must occur in some manner between the albumin and the Fc fragment since the F(ab')2 fragment does not give rise to agglutination under such conditions. Images Figure 1 PMID:415968

  5. Comparison of methods for the extraction of DNA from formalin-fixed, paraffin-embedded archival tissues.

    PubMed

    Sengüven, Burcu; Baris, Emre; Oygur, Tulin; Berktas, Mehmet

    2014-01-01

    Discussing a protocol involving xylene-ethanol deparaffinization on slides followed by a kit-based extraction that allows for the extraction of high quality DNA from FFPE tissues. DNA was extracted from the FFPE tissues of 16 randomly selected blocks. Methods involving deparaffinization on slides or tubes, enzyme digestion overnight or for 72 hours and isolation using phenol chloroform method or a silica-based commercial kit were compared in terms of yields, concentrations and the amplifiability. The highest yield of DNA was produced from the samples that were deparaffinized on slides, digested for 72 hours and isolated with a commercial kit. Samples isolated with the phenol-chloroform method produced DNA of lower purity than the samples that were purified with kit. The samples isolated with the commercial kit resulted in better PCR amplification. Silica-based commercial kits and deparaffinized on slides should be considered for DNA extraction from FFPE.

  6. Slip and Slide Method of Factoring Trinomials with Integer Coefficients over the Integers

    ERIC Educational Resources Information Center

    Donnell, William A.

    2012-01-01

    In intermediate and college algebra courses there are a number of methods for factoring quadratic trinomials with integer coefficients over the integers. Some of these methods have been given names, such as trial and error, reversing FOIL, AC method, middle term splitting method and slip and slide method. The purpose of this article is to discuss…

  7. Adaptive fuzzy sliding control of single-phase PV grid-connected inverter.

    PubMed

    Fei, Juntao; Zhu, Yunkai

    2017-01-01

    In this paper, an adaptive fuzzy sliding mode controller is proposed to control a two-stage single-phase photovoltaic (PV) grid-connected inverter. Two key technologies are discussed in the presented PV system. An incremental conductance method with adaptive step is adopted to track the maximum power point (MPP) by controlling the duty cycle of the controllable power switch of the boost DC-DC converter. An adaptive fuzzy sliding mode controller with an integral sliding surface is developed for the grid-connected inverter where a fuzzy system is used to approach the upper bound of the system nonlinearities. The proposed strategy has strong robustness for the sliding mode control can be designed independently and disturbances can be adaptively compensated. Simulation results of a PV grid-connected system verify the effectiveness of the proposed method, demonstrating the satisfactory robustness and performance.

  8. Are the Major Agglutinative Languages Genetically Related?

    ERIC Educational Resources Information Center

    Hakola, H. P. A.

    1989-01-01

    Examination of accidental CVC and CV correspondences among languages representing 5 large families of agglutinative languages found that comparison pairs had much more similarity between basic 100-word vocabularies than would have been possible by mere chance, supporting the hypothesis that those 5 language families were mutually related.…

  9. Single-molecule detection of proteins with antigen-antibody interaction using resistive-pulse sensing of submicron latex particles

    NASA Astrophysics Data System (ADS)

    Takakura, T.; Yanagi, I.; Goto, Y.; Ishige, Y.; Kohara, Y.

    2016-03-01

    We developed a resistive-pulse sensor with a solid-state pore and measured the latex agglutination of submicron particles induced by antigen-antibody interaction for single-molecule detection of proteins. We fabricated the pore based on numerical simulation to clearly distinguish between monomer and dimer latex particles. By measuring single dimers agglutinated in the single-molecule regime, we detected single human alpha-fetoprotein molecules. Adjusting the initial particle concentration improves the limit of detection (LOD) to 95 fmol/l. We established a theoretical model of the LOD by combining the reaction kinetics and the counting statistics to explain the effect of initial particle concentration on the LOD. The theoretical model shows how to improve the LOD quantitatively. The single-molecule detection studied here indicates the feasibility of implementing a highly sensitive immunoassay by a simple measurement method using resistive-pulse sensing.

  10. Diagnosis of group A streptococcal infections directly from throat secretions.

    PubMed Central

    Edwards, E A; Phillips, I A; Suiter, W C

    1982-01-01

    The diagnosis of group A streptococcal disease still relies on isolation of group A streptococcal strains on sheep blood agar followed by presumptive identification based on bacitracin sensitivity or the results of the more precise serogrouping methods such as the Lancefield precipitin test. A technique that would permit rapid identification of streptococcal infections directly from throat secretions would allow immediate appropriate antimicrobial therapy for the management of streptococcal infections to be started. We have been able to identify soluble group A antigen directly from throat secretions by using a latex agglutination test. In a clinical trial in which latex (Streptex group A) and conventional culturing techniques were used, 53 throat secretion cultures were tested: 26 were positive by both procedures, 5 were positive by culture only, 3 were positive by the latex agglutination test only, and 19 were negative by both tests. Images PMID:7042747

  11. Assessment of methicillin resistant Staphylococcus Aureus detection methods: analytical comparative study.

    PubMed

    Ibrahim, Omer Mohammed Ali; Bilal, Naser Eldin; Osman, Omran Fadl; Magzoub, Magzoub Abbas

    2017-01-01

    The heterogeneous expression of methicillin resistance in Staphylococcus aureus (MRSA) affects the efficiency of tests available to detect it. The objective of this study was to assess four phenotypic tests used to detect MRSA. This is an analytical comparative study conducted among sudanese patients during period from May 2012 to July 2014, Staphylococcus aureus strains were isolated and identified by conventional methods, and then confirmed by PCR detection of coagulase gene. PCR detection of mecA gene was used as a gold standard to assess oxacillin resistance screen agar base (ORSAB), oxacillin disc, cefoxitin disc (at different temperatures and incubation periods) and MRSA-latex agglutination test. S.aureus ATCC 25923 was used as control. Sensitivity and specificity were calculated. MRSA- latex agglutination was the most accurate test; it showed 100% of both sensitivity and specificity, followed by cefoxitin disc with sensitivity of 98.48% and specificity of 100%. However, both of oxacillin disc and oxacillin resistance screen agar base showed less accurate results, and were affected by incubation periods. Oxacillin disc after 24 h incubation both at 30°C and 35°C showed sensitivity and specificity values of 87.88% and 96.23%, respectively. However, after 48h incubation the test at 30°C showed sensitivity and specificity values of 89.39%, and 94.34%, respectively. At 35°C (48h) it showed values of 89.39%, 92.45% respectively. Specificity of ORSAB was more than oxacillin disc at 35°C after 24h incubation 98.11% and 96.23%, respectively. MRSA- latex agglutination and cefoxitin disc diffusion tests are recommended for routine detection of MRSA.

  12. Development and evaluation of an off-the-slide genotyping technique for identifying Giardia cysts and Cryptosporidium oocysts directly from US EPA Method 1623 slides.

    PubMed

    Ware, M W; Keely, S P; Villegas, E N

    2013-07-01

    This study developed and systematically evaluated performance and limit of detection of an off-the-slide genotyping procedure for both Cryptosporidium oocysts and Giardia cysts. Slide standards containing flow-sorted (oo)cysts were used to evaluate the off-the-slide genotyping procedure by microscopy and PCR. Results show approximately 20% of cysts and oocysts are lost during staining. Although transfer efficiency from the slide to the PCR tube could not be determined by microscopy, it was observed that the transfer process aided in the physical lysis of the (oo)cysts likely releasing DNA. PCR detection rates for a single event on a slide were 44% for Giardia and 27% for Cryptosporidium, and a minimum of five cysts and 20 oocysts are required to achieve a 90% PCR detection rate. A Poisson distribution analysis estimated the relative PCR target densities and limits of detection, it showed that 18 Cryptosporidium and five Giardia replicates are required for a 95% probability of detecting a single (oo)cyst on a slide. This study successfully developed and evaluated recovery rates and limits of detection of an off-the-slide genotyping procedure for both Cryptosporidium and Giardia (oo)cysts from the same slide. This off-the-slide genotyping technique is a simple and low cost tool that expands the applications of US EPA Method 1623 results by identifying the genotypes and assemblages of the enumerated Cryptosporidium and Giardia. This additional information will be useful for microbial risk assessment models and watershed management decisions. Journal of Applied Microbiology Published [2013]. This article is a U.S. Government work and is in the public domain in the USA.

  13. Study on the Prevalence of Leptospirosis among Fever Cases Reported from Private Clinics in the Urban areas of Villupuram District, Tamil Nadu, India

    PubMed Central

    Basker, Parasuraman; Kannan, Pichai; Kolandaswamy, Karumana Gounder

    2014-01-01

    Objectives To know the prevalence of leptospirosis cases reported in private clinics among fever cases in Villupuram District, Tamil Nadu, India to know its real magnitude of the problem and to diagnose Leptospirosis among fever cases from differential diagnosis. Methods 1502 Blood serum samples collected from three urban towns namely Kallakurichi (Latitude: 11° 73′ N; Longitude: 78° 97′ E), Villupuram (Latitude: 11° 75′ N; Longitude: 79° 92′ E) and Thindivanam (Latitude: 12° 25′ N; Longitude: 79° 65′ E) in fifteen clinics based on case definition of leptospirosis delineated by the National Vector Borne Disease Control Programme (NVBDCP), Government of India. Samples were tested in the laboratory of the Zonal Entomological Team (ZET), Cuddalore with Macroscopic Slide Agglutination Test (MSAT) and Ig-M ELISA. Result There were 65 positive cases detected from 1502 blood serum samples in both MSAT and Ig-M ELISA. It could be known that there was 4% cases contributed from private clinics among fever cases. From this study, further it was known that all age groups of people affected irrespective of sexes based on their living condition associated with the environment prevailed of the disease. Conclusion From this study, it was quantified that 4% of cases reported in private clinics among fever cases and its findings ascertained both the importance of differential diagnosis as well as reports that should be included to the Government for knowing its real magnitude for planning. PMID:24955313

  14. Quality of commercially produced Shigella serogrouping and serotyping antisera.

    PubMed Central

    Evins, G M; Gheesling, L L; Tauxe, R V

    1988-01-01

    Shigella grouping antisera from five manufacturers and typing antisera from two were purchased and evaluated with homologous and heterologous Shigella strains in the slide agglutination test. Only 31 of 73 (42%) antisera were satisfactory. In many instances, the antisera gave negative, as opposed to weak, reactions when they should have given strong positive reactions. Four reagents cross-reacted with Shigella strains. Of the 19 polyvalent grouping antisera to subgroups Shigella dysenteriae serotypes 1 through 7, S. flexneri serotypes 1 through 6, S. boydii serotypes 1 through 7, and S. sonnei forms I, II, only one S. sonnei reagent and five S. flexneri reagents were satisfactory with greater than or equal to 90% of the homologous strains. The reagent of poorest quality was satisfactory with only 18% of the homologous strains. There were three polyvalent antisera to the higher types of S. dysenteriae and S. boydii, which were available from only one company, that adequately identified 80, 63, and 65% of the homologous strains. Typing antisera were available from only two companies, and 30 of 51 (59%) were satisfactory. Commercially available Shigella antisera are inadequate for the laboratory testing required for planning the development of and evaluating Shigella vaccines. PMID:3281972

  15. Robust Neural Sliding Mode Control of Robot Manipulators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nguyen Tran Hiep; Pham Thuong Cat

    2009-03-05

    This paper proposes a robust neural sliding mode control method for robot tracking problem to overcome the noises and large uncertainties in robot dynamics. The Lyapunov direct method has been used to prove the stability of the overall system. Simulation results are given to illustrate the applicability of the proposed method.

  16. Comparison of Methods for the Extraction of DNA from Formalin-Fixed, Paraffin-Embedded Archival Tissues

    PubMed Central

    Sengüven, Burcu; Baris, Emre; Oygur, Tulin; Berktas, Mehmet

    2014-01-01

    Aim: Discussing a protocol involving xylene-ethanol deparaffinization on slides followed by a kit-based extraction that allows for the extraction of high quality DNA from FFPE tissues. Methods: DNA was extracted from the FFPE tissues of 16 randomly selected blocks. Methods involving deparaffinization on slides or tubes, enzyme digestion overnight or for 72 hours and isolation using phenol chloroform method or a silica-based commercial kit were compared in terms of yields, concentrations and the amplifiability. Results: The highest yield of DNA was produced from the samples that were deparaffinized on slides, digested for 72 hours and isolated with a commercial kit. Samples isolated with the phenol-chloroform method produced DNA of lower purity than the samples that were purified with kit. The samples isolated with the commercial kit resulted in better PCR amplification. Conclusion: Silica-based commercial kits and deparaffinized on slides should be considered for DNA extraction from FFPE. PMID:24688314

  17. Cytopathology whole slide images and adaptive tutorials for postgraduate pathology trainees: a randomized crossover trial.

    PubMed

    Van Es, Simone L; Kumar, Rakesh K; Pryor, Wendy M; Salisbury, Elizabeth L; Velan, Gary M

    2015-09-01

    To determine whether cytopathology whole slide images and virtual microscopy adaptive tutorials aid learning by postgraduate trainees, we designed a randomized crossover trial to evaluate the quantitative and qualitative impact of whole slide images and virtual microscopy adaptive tutorials compared with traditional glass slide and textbook methods of learning cytopathology. Forty-three anatomical pathology registrars were recruited from Australia, New Zealand, and Malaysia. Online assessments were used to determine efficacy, whereas user experience and perceptions of efficiency were evaluated using online Likert scales and open-ended questions. Outcomes of online assessments indicated that, with respect to performance, learning with whole slide images and virtual microscopy adaptive tutorials was equivalent to using traditional methods. High-impact learning, efficiency, and equity of learning from virtual microscopy adaptive tutorials were strong themes identified in open-ended responses. Participants raised concern about the lack of z-axis capability in the cytopathology whole slide images, suggesting that delivery of z-stacked whole slide images online may be important for future educational development. In this trial, learning cytopathology with whole slide images and virtual microscopy adaptive tutorials was found to be as effective as and perceived as more efficient than learning from glass slides and textbooks. The use of whole slide images and virtual microscopy adaptive tutorials has the potential to provide equitable access to effective learning from teaching material of consistently high quality. It also has broader implications for continuing professional development and maintenance of competence and quality assurance in specialist practice. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Frictional sliding inclusions

    NASA Astrophysics Data System (ADS)

    Huang, Jin H.; Furuhashi, R.; Mura, T.

    1993-02-01

    S OLUTIONS ARE presented in closed form by using an averaging method for inclusions sliding along an interface due to uniform eigenstrains precribed in the inclusions. The associated stress fields are also analytically determined. A parameter s is introduced to indicate the relative magnitude of sliding compared with the extreme cases of perfect bonding and perfect sliding. When the parameter s becomes zero, the present solution coincides with Eshelby's solution which is the perfectly bonded case. In contrast, when the parameter s is unity, the solution agrees with Volterra's solution (M URA and F URUHASHI, 1984, J. appl. Mech.51, 308] for the perfect sliding case. Because of non-uniform elastic fields caused by sliding along the interface, the well-known Eshelby tensor is modified for the sliding inclusions. Moreover, based on the Mori-Tanaka theory (M ORI and T ANAKA, 1973, Acta Metall.21, 571), an overall stress-strain relation is established to characterize the sliding effect on the overall elastic moduli.

  19. Color standardization in whole slide imaging using a color calibration slide

    PubMed Central

    Bautista, Pinky A.; Hashimoto, Noriaki; Yagi, Yukako

    2014-01-01

    Background: Color consistency in histology images is still an issue in digital pathology. Different imaging systems reproduced the colors of a histological slide differently. Materials and Methods: Color correction was implemented using the color information of the nine color patches of a color calibration slide. The inherent spectral colors of these patches along with their scanned colors were used to derive a color correction matrix whose coefficients were used to convert the pixels’ colors to their target colors. Results: There was a significant reduction in the CIELAB color difference, between images of the same H & E histological slide produced by two different whole slide scanners by 3.42 units, P < 0.001 at 95% confidence level. Conclusion: Color variations in histological images brought about by whole slide scanning can be effectively normalized with the use of the color calibration slide. PMID:24672739

  20. Quantification of histochemical stains using whole slide imaging: development of a method and demonstration of its usefulness in laboratory quality control.

    PubMed

    Gray, Allan; Wright, Alex; Jackson, Pete; Hale, Mike; Treanor, Darren

    2015-03-01

    Histochemical staining of tissue is a fundamental technique in tissue diagnosis and research, but it suffers from significant variability. Efforts to address this include laboratory quality controls and quality assurance schemes, but these rely on subjective interpretation of stain quality, are laborious and have low reproducibility. We aimed (1) to develop a method for histochemical stain quantification using whole slide imaging and image analysis and (2) to demonstrate its usefulness in measuring staining variation. A method to quantify the individual stain components of histochemical stains on virtual slides was developed. It was evaluated for repeatability and reproducibility, then applied to control sections of an appendix to quantify H&E staining (H/E intensities and H:E ratio) between automated staining machines and to measure differences between six regional diagnostic laboratories. The method was validated with <0.5% variation in H:E ratio measurement when using the same scanner for a batch of slides (ie, it was repeatable) but was not highly reproducible between scanners or over time, where variation of 7% was found. Application of the method showed H:E ratios between three staining machines varied from 0.69 to 0.93, H:E ratio variation over time was observed. Interlaboratory comparison demonstrated differences in H:E ratio between regional laboratories from 0.57 to 0.89. A simple method using whole slide imaging can be used to quantify and compare histochemical staining. This method could be deployed in routine quality assurance and quality control. Work is needed on whole slide imaging devices to improve reproducibility. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  1. Rapid and Accurate Multiple Testing Correction and Power Estimation for Millions of Correlated Markers

    PubMed Central

    Han, Buhm; Kang, Hyun Min; Eskin, Eleazar

    2009-01-01

    With the development of high-throughput sequencing and genotyping technologies, the number of markers collected in genetic association studies is growing rapidly, increasing the importance of methods for correcting for multiple hypothesis testing. The permutation test is widely considered the gold standard for accurate multiple testing correction, but it is often computationally impractical for these large datasets. Recently, several studies proposed efficient alternative approaches to the permutation test based on the multivariate normal distribution (MVN). However, they cannot accurately correct for multiple testing in genome-wide association studies for two reasons. First, these methods require partitioning of the genome into many disjoint blocks and ignore all correlations between markers from different blocks. Second, the true null distribution of the test statistic often fails to follow the asymptotic distribution at the tails of the distribution. We propose an accurate and efficient method for multiple testing correction in genome-wide association studies—SLIDE. Our method accounts for all correlation within a sliding window and corrects for the departure of the true null distribution of the statistic from the asymptotic distribution. In simulations using the Wellcome Trust Case Control Consortium data, the error rate of SLIDE's corrected p-values is more than 20 times smaller than the error rate of the previous MVN-based methods' corrected p-values, while SLIDE is orders of magnitude faster than the permutation test and other competing methods. We also extend the MVN framework to the problem of estimating the statistical power of an association study with correlated markers and propose an efficient and accurate power estimation method SLIP. SLIP and SLIDE are available at http://slide.cs.ucla.edu. PMID:19381255

  2. Monitoring environmental change with color slides

    Treesearch

    Arthur W. Magill

    1989-01-01

    Monitoring human impact on outdoor recreation sites and view landscapes is necessary to evaluate influences which may require corrective action and to determine if management is achieving desired goals. An inexpensive method to monitor environmental change is to establish camera points and use repeat color slides. Successful monitoring from slides requires the observer...

  3. Design and analysis of adaptive Super-Twisting sliding mode control for a microgyroscope.

    PubMed

    Feng, Zhilin; Fei, Juntao

    2018-01-01

    This paper proposes a novel adaptive Super-Twisting sliding mode control for a microgyroscope under unknown model uncertainties and external disturbances. In order to improve the convergence rate of reaching the sliding surface and the accuracy of regulating and trajectory tracking, a high order Super-Twisting sliding mode control strategy is employed, which not only can combine the advantages of the traditional sliding mode control with the Super-Twisting sliding mode control, but also guarantee that the designed control system can reach the sliding surface and equilibrium point in a shorter finite time from any initial state and avoid chattering problems. In consideration of unknown parameters of micro gyroscope system, an adaptive algorithm based on Lyapunov stability theory is designed to estimate the unknown parameters and angular velocity of microgyroscope. Finally, the effectiveness of the proposed scheme is demonstrated by simulation results. The comparative study between adaptive Super-Twisting sliding mode control and conventional sliding mode control demonstrate the superiority of the proposed method.

  4. M-cholinoreactivity of erythrocytes of non-pregnant and pregnant women evaluated by changes in the rate of erythrocyte agglutination under the influence of acetylcholine.

    PubMed

    Strelnikova, A I; Tsirkin, V I; Krysova, A V; Hlybova, S V; Dmitrieva, S L

    2012-12-01

    Acetylcholine (5.5×10(-10)-5.5×10(-6)M) accelerated erythrocyte agglutination in men, non-pregnant women in follicular phase of the menstrual cycle, and pregnant women in the first trimester. The effect was blocked with atropine (5.5×10(-6)M). Acetylcholine had no effect on the rate of erythrocyte agglutination in non-pregnant women in the luteal phase and pregnant women in the second and third trimesters, which coincided with the development of myometrium refractoriness to acetylcholine in pregnant women. The results indicate that erythrocytes can reflect M-cholinoreactivity of internal organs.

  5. Integral Sliding Mode Fault-Tolerant Control for Uncertain Linear Systems Over Networks With Signals Quantization.

    PubMed

    Hao, Li-Ying; Park, Ju H; Ye, Dan

    2017-09-01

    In this paper, a new robust fault-tolerant compensation control method for uncertain linear systems over networks is proposed, where only quantized signals are assumed to be available. This approach is based on the integral sliding mode (ISM) method where two kinds of integral sliding surfaces are constructed. One is the continuous-state-dependent surface with the aim of sliding mode stability analysis and the other is the quantization-state-dependent surface, which is used for ISM controller design. A scheme that combines the adaptive ISM controller and quantization parameter adjustment strategy is then proposed. Through utilizing H ∞ control analytical technique, once the system is in the sliding mode, the nature of performing disturbance attenuation and fault tolerance from the initial time can be found without requiring any fault information. Finally, the effectiveness of our proposed ISM control fault-tolerant schemes against quantization errors is demonstrated in the simulation.

  6. Adaptive fuzzy sliding control of single-phase PV grid-connected inverter

    PubMed Central

    Zhu, Yunkai

    2017-01-01

    In this paper, an adaptive fuzzy sliding mode controller is proposed to control a two-stage single-phase photovoltaic (PV) grid-connected inverter. Two key technologies are discussed in the presented PV system. An incremental conductance method with adaptive step is adopted to track the maximum power point (MPP) by controlling the duty cycle of the controllable power switch of the boost DC-DC converter. An adaptive fuzzy sliding mode controller with an integral sliding surface is developed for the grid-connected inverter where a fuzzy system is used to approach the upper bound of the system nonlinearities. The proposed strategy has strong robustness for the sliding mode control can be designed independently and disturbances can be adaptively compensated. Simulation results of a PV grid-connected system verify the effectiveness of the proposed method, demonstrating the satisfactory robustness and performance. PMID:28797060

  7. Combined neutrophil and erythrocyte agglutination in a 7-year-old boy.

    PubMed

    Yenson, Paul R; Fleming, Adam; Kaikov, Yigal; Wadsworth, Louis D

    2007-09-01

    Leukoagglutination is a rare in vitro phenomenon, with demonstration of both temperature and/or ethylenediaminetetraacetic acid dependence. We report a case of combined leukocyte and erythrocyte agglutination in a 7-year-old male with Mycoplasma pneumoniae and Epstein-Barr virus coinfection. To our knowledge, this morphologic finding has not previously been described.

  8. Interfering lipoproteins in magnetic field-assisted agglutination of superparamagnetic particles immunoassay.

    PubMed

    Cauet, Gilles; Daynès, Aurélien; Temurok, Nevzat

    2016-04-01

    The technology of magnetic field-assisted immuno-agglutination of superparamagnetic particles allows sensitive detection of biomarkers in whole blood. However, we observed non-specific agglutination (NSA), due to interfering plasma proteins, that negatively affects C-reactive protein immunoassay. The objective of the study was to identify the plasma proteins involved and to eliminate these interferences. Plasma was fractionated by size exclusion HPLC and each fraction was tested for non-specific agglutination. In addition, plasma proteins bound to magnetic particles were analyzed by SDS-gel electrophoresis and identified by mass spectrometry. We found that NSA was due to the binding of some lipoproteins to the particles. NSA was observed in the presence of purified LDL and VLDL but not HDL. NSA was mediated by the binding of ApoB100 to magnetic particles through its heparin binding sites. These interferences could be eliminated by addition of heparin or other polyanions like dextran sulfate to the assay buffer. NSA results from the binding of some plasma lipoproteins to magnetic particles. The use of a polyanion to eliminate these interferences allows the formulation of a stable reagent.

  9. Integrated investigation of the mixed origin of lunar sample 72161,11

    NASA Technical Reports Server (NTRS)

    Basu, A.; Des Marais, D. J.; Hayes, J. M.; Meinschein, W. G.

    1975-01-01

    The comminution-agglutination model and the solar-wind implantation-retention model are used to postulate the origins of the particulate components of lunar sample (72161,11), a submillimeter fraction of a surface sample for the dark mantle regolith at LRV-3. Grain-size analysis was performed by wet sieving with liquid argon, and analyses for CO2, CO, CH4, and H2 were carried out by stepwise pyrolysis in a helium atmosphere. The results indicate that the present sample is from a mature regolith, but the agglutinate content is only 30% in the particle-size range between 90 and 177 microns, indicating an apparent departure from steady state. Analyses of the carbon, methane, and hydrogen concentrations in size fractions larger than 149 microns show that the volume-correlated component of these species increases with increased grain size. It is suggested that the observed increase can be explained in terms of mixing of a dominant local population of coarser agglutinates having high carbon and hydrogen concentrations with an imported population of finer agglutinates relatively poor in carbon and hydrogen.

  10. Lectins discriminate between pathogenic and nonpathogenic South American trypanosomes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    de Miranda Santos, I.K.; Pereira, M.E.

    1984-09-01

    Cell surface carbohydrates of Trypanosoma cruzi, Trypanosoma rangeli, and Trypanosoma conorhini were analyzed by a micro-agglutination assay employing 27 highly purified lectins and by binding assays using various /sup 125/I-labeled lectins. The following seven lectins discriminated between the trypanosomes: 1) tomato lectin (an N-acetyl-D-glucosamine-binding protein), both in purified form and as crude tomato juice; 2) Bauhinea purpurea and Sophora japonica lectins (both N-acetyl-D-galactosamine-binding proteins), which selectively agglutinated T. cruzi; 3) Vicia villosa (an N-acetyl-D-galactosamine-binding protein) which was specific for T. rangeli; 4) peanut lectin (a D-galactose-binding protein) both in purified form and as crude saline extract; and 5) Ulex europaeusmore » and Lotus tetragonolobus (both L-fucose-binding proteins) lectins which reacted only with T. conorhini. Binding studies with 125I-labeled lectins were performed to find whether unagglutinated cells of the three different species of trypanosomes might have receptors for these lectins, in which case absence of agglutination could be due to a peculiar arrangement of the receptors. These assays essentially confirmed the agglutination experiments.« less

  11. Screening of agglutinins in marine algae from Fujian coast of China

    NASA Astrophysics Data System (ADS)

    Zheng, Yi; Lu, Hai-Sheng

    2002-09-01

    Thirty-three species of marine algae belonging to Rhodophyta, Phaeophyta and Chlorophyta from the Fujian coast were examined for agglutinins with different animal and human erythrocytes. Protein extracts from 26 species were active against at least one type of the erythrocytes tested. There were 3 species ( Grateloupia imbricata, Ishige foliacea and Entermorpha prolifera) whose extracts could agglutimate all the erythrocytes used. The lowest protein concentration required to produce erythrocyte agglutination varied remarkably, from 3.1 μg/ml to 500 μg/ml. The strongest activity was found in the agglutination of rabbit erythrocytes by Gloiopeltis furcata extract. Inhibition assays performed with nine mono- and bisaccharides indicated that agglutinations of rabbit erythrocytes by extracts of 7 species were inhibited by one or more types of the sugars assayed. The agglutinating activity shown by extracts of most species was not affected when the test solution was heated to 90°C, but was lost at 95°C 100°C. A few extracts lost their activity at 60°C, 65°C and 75°C, respectively.

  12. Avian P1 antigens inhibit agglutination mediated by P fimbriae of uropathogenic Escherichia coli.

    PubMed Central

    Johnson, J R; Swanson, J L; Neill, M A

    1992-01-01

    Whole egg white from pigeon, dove, and cockatiel eggs, as well as the ovomucoid fraction of pigeon egg white, exhibited strong P1 antigenic activities and inhibited agglutination of human P1 erythrocytes and of digalactoside-coated latex beads by P-fimbriated Escherichia coli strains. In contrast, chicken egg white exhibited only weak P1 antigenic activity and had little impact on P-fimbrial agglutination. These preparations did not affect hemagglutination by E. coli strains expressing mannose-resistant adhesins other than P fimbriae, i.e., Dr, F1845, and S adhesins. Human anti-P1 serum diminished the P-fimbrial inhibitory activities of pigeon egg white and pigeon ovomucoid. Pigeon ovomucoid was equipotent on a molar basis with globoside, and the pigeon, dove, and cockatiel egg white preparations were equipotent with each other in P-fimbrial inhibition. Incubation of p erythrocytes in whole egg whites or in pigeon ovomucoid did not render them agglutinable by P-fimbriated bacteria, whereas incubation in globoside did. These data demonstrate that whole egg whites (and their ovomucoid fraction) from members of the families Columbidae (pigeons and doves) and Psittacidae (parrots) specifically and potently inhibit P-fimbrial agglutination, probably by providing P1 antigen as a receptor for the P-fimbrial adhesin. Avian egg white preparations may facilitate adhesin characterization of wild-type uropathogenic strains and may useful in preventing upper urinary tract infections due to P-fimbriated E. coli. PMID:1346125

  13. Studies on the interaction of the Sophora japonica lectin and concanavalin A with erythrocytes and lymphocytes.

    PubMed Central

    Poretz, R D; Barth, R F

    1976-01-01

    The agglutinating activity of lectins from the seeds of Sophora japonica and Canavalia ensiformis (concanavalin A) with human and murine erythrocytes and lymphocytes have been compared to one another and related to the mitogenic and immunosuppressive properties of these purified proteins. The S. japonica lectin, which demonstrates blood group specificity, is more active than concanavalin A with human erythrocytes, but has a much lower reactivity than concanavalin A with murine red blood cells. Ficin treatment of human erythrocytes results in an increase in agglutinability by both lectins as well as causing the appearance of S. japonica lectin receptors on type O cells. Treatment of murine reythrocytes with ficin alone or followed by beta-galactosidase causes the cells to be more reactive with concanavalin A. Beta-Galactosidase alone has no observable affect on the cells. In contrast, the agglutinability of cells by the S. japonica lectin increases after ficin treatment but is not affected by beta-galaetosidose treatment either after or in the absence of ficinization. Murine lymphocytes react with both lectins in a manner paralleling the agglutination patterns of murine erythrocytes. The S. japonica lectin appears to be devoid of mitogenic and immuno-suppressive activity, in contrast to concanavalin A which suppresses the T helper-dependent antibody response to sheep erythrocytes. These results are discussed in terms of the types of lectin receptors on lymphocytes related to agglutination, induction of blastogenesis and immuno-suppression. PMID:955676

  14. IMMUNOREACTIONS INVOLVING PLATELETS

    PubMed Central

    Shulman, N. Raphael

    1958-01-01

    Quantitative aspects of platelet agglutination and inhibition of clot retraction by the antibody of quinidine purpura were described. The reactions appeared to depend on formation of types of antibody-quinidine-platelet complexes which could fix complement but complement was not necessary for these reactions. Complement fixation was at least 10 times more sensitive than platelet agglutination or inhibition of clot retraction for measurement and detection of antibody activity. Although it has been considered that antibodies of drug purpura act as platelet lysins in the presence of complement and that direct lysis of platelets accounts for development of thrombocytopenia in drug purpura, the present study suggests that attachment of antibody produces a change in platelets which is manifested in vitro only by increased susceptibility to non-specific factors which can alter the stability of platelets in the absence of antibody. The attachment of antibody to platelets in vivo may only indirectly affect platelet survival. In contrast to human platelets, dog, rabbit, and guinea pig platelets, and normal or trypsin-treated human red cells did not agglutinate, fix complement, or adsorb antibody; and intact human endothelial cells did not fix complement or adsorb antibody. Rhesus monkey platelets were not agglutinated by the antibody but did adsorb antibody and fix complement although their activity in these reactions differed quantitatively from that of human platelets. Cinchonine could be substituted for quinidine in agglutination and inhibition of clot retraction reactions but quinine and cinchonidine could not. Attempts to cause passive anaphylaxis in guinea pigs with the antibody of quinidine purpura were not successful. PMID:13525580

  15. Modeling of Virion Collisions in Cervicovaginal Mucus Reveals Limits on Agglutination as the Protective Mechanism of Secretory Immunoglobulin A

    PubMed Central

    Chen, Alex; McKinley, Scott A.; Shi, Feng; Wang, Simi; Mucha, Peter J.; Harit, Dimple; Forest, M. Gregory; Lai, Samuel K.

    2015-01-01

    Secretory immunoglobulin A (sIgA), a dimeric antibody found in high quantities in the gastrointestinal mucosa, is broadly associated with mucosal immune protection. A distinguishing feature of sIgA is its ability to crosslink pathogens, thereby creating pathogen/sIgA aggregates that are too large to traverse the dense matrix of mucin fibers in mucus layers overlying epithelial cells and consequently reducing infectivity. Here, we use modeling to investigate this mechanism of “immune exclusion” based on sIgA-mediated agglutination, in particular the potential use of sIgA to agglutinate HIV in cervicovaginal mucus (CVM) and prevent HIV transmission. Utilizing reported data on HIV diffusion in CVM and semen, we simulate HIV collision kinetics in physiologically-thick mucus layers–a necessary first step for sIgA-induced aggregation. We find that even at the median HIV load in semen of acutely infected individuals possessing high viral titers, over 99% of HIV virions will penetrate CVM and reach the vaginal epithelium without colliding with another virion. These findings imply that agglutination is unlikely to be the dominant mechanism of sIgA-mediated protection against HIV or other sexually transmitted pathogens. Rather, we surmise that agglutination is most effective against pathogens either present at exceedingly high concentrations or that possess motility mechanisms other than Brownian diffusion that significantly enhance encounter rates. PMID:26132216

  16. Passivity-based sliding mode control for a polytopic stochastic differential inclusion system.

    PubMed

    Liu, Leipo; Fu, Zhumu; Song, Xiaona

    2013-11-01

    Passivity-based sliding mode control for a polytopic stochastic differential inclusion (PSDI) system is considered. A control law is designed such that the reachability of sliding motion is guaranteed. Moreover, sufficient conditions for mean square asymptotic stability and passivity of sliding mode dynamics are obtained by linear matrix inequalities (LMIs). Finally, two examples are given to illustrate the effectiveness of the proposed method. © 2013 ISA. Published by ISA. All rights reserved.

  17. Ultra-precision positioning assembly

    DOEpatents

    Montesanti, Richard C.; Locke, Stanley F.; Thompson, Samuel L.

    2002-01-01

    An apparatus and method is disclosed for ultra-precision positioning. A slide base provides a foundational support. A slide plate moves with respect to the slide base along a first geometric axis. Either a ball-screw or a piezoelectric actuator working separate or in conjunction displaces the slide plate with respect to the slide base along the first geometric axis. A linking device directs a primary force vector into a center-line of the ball-screw. The linking device consists of a first link which directs a first portion of the primary force vector to an apex point, located along the center-line of the ball-screw, and a second link for directing a second portion of the primary force vector to the apex point. A set of rails, oriented substantially parallel to the center-line of the ball-screw, direct movement of the slide plate with respect to the slide base along the first geometric axis and are positioned such that the apex point falls within a geometric plane formed by the rails. The slide base, the slide plate, the ball-screw, and the linking device together form a slide assembly. Multiple slide assemblies can be distributed about a platform. In such a configuration, the platform may be raised and lowered, or tipped and tilted by jointly or independently displacing the slide plates.

  18. A critical role for the regulation of Syk from agglutination to aggregation in human platelets.

    PubMed

    Shih, Chun-Ho; Chiang, Tin-Bin; Wang, Wen-Jeng

    2014-01-10

    Agglucetin, a tetrameric glycoprotein (GP) Ibα agonist from Formosan Agkistrodon acutus venom, has been characterized as an agglutination inducer in human washed platelets (WPs). In platelet-rich plasma (PRP), agglucetin dramatically elicits a biphasic response of agglutination and subsequent aggregation. For clarifying the intracellular signaling events from agglutination to aggregation in human platelets, we examined the essential signaling molecules involved through the detection of protein tyrosine phosphorylation (PTP). In WPs, an anti-GPIbα monoclonal antibody (mAb) AP1, but not a Src kinase inhibitor PP1, completely inhibited agglucetin-induced agglutination. However, PP1 but not AP1 had a potent suppression on platelet aggregation by a GPVI activator convulxin. The PTP analyses showed agglucetin alone can cause a weak pattern involving sequential phosphorylation of Lyn/Fyn, Syk, SLP-76 and phospholipase Cγ2 (PLCγ2). Furthermore, a Syk-selective kinase inhibitor, piceatannol, significantly suppressed the aggregating response in agglucetin-activated PRP. Analyzed by flow cytometry, the binding capacity of fluorophore-conjugated PAC-1, a mAb recognizing activated integrin αIIbβ3, was shown to increase in agglucetin-stimulated platelets. Again, piceatannol but not PP1 had a concentration-dependent suppression on agglucetin-induced αIIbβ3 exposure. Moreover, the formation of signalosome, including Syk, SLP-76, VAV, adhesion and degranulation promoting adapter protein (ADAP) and PLCγ2, are required for platelet aggregation in agglucetin/fibrinogen-activated platelets. In addition, GPIbα-ligation via agglucetin can substantially promote the interactions between αIIbβ3 and fibrinogen. Therefore, the signal pathway of Lyn/Fyn/Syk/SLP-76/ADAP/VAV/PLCγ2/PKC is sufficient to trigger platelet aggregation in agglucetin/fibrinogen-pretreated platelets. Importantly, Syk may function as a major regulator for the response from GPIbα-initiated agglutination to integrin αIIbβ3-dependent aggregation in human platelets. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. A scallop C-type lectin from Argopecten irradians (AiCTL5) with activities of lipopolysaccharide binding and Gram-negative bacteria agglutination.

    PubMed

    Mu, Changkao; Song, Xiaoyan; Zhao, Jianmin; Wang, Lingling; Qiu, Limei; Zhang, Huan; Zhou, Zhi; Wang, Mengqiang; Song, Linsheng; Wang, Chunlin

    2012-05-01

    C-type lectins are a family of calcium-dependent carbohydrate-binding proteins. In the present study, a C-type lectin (designated as AiCTL5) was identified and characterized from Argopecten irradians. The full-length cDNA of AiCTL5 was of 673 bp, containing a 5' untranslated region (UTR) of 24 bp, a 3' UTR of 130 bp with a poly (A) tail, and an open reading frame (ORF) of 519 bp encoding a polypeptide of 172 amino acids with a putative signal peptide of 17 amino acids. A C-type lectin-like domain (CRD) containing 6 conserved cysteines and a putative glycosylation sites were identified in the deduced amino acid sequence of AiCTL5. AiCTL5 shared 11%-27.5% identity with the previous reported C-type lectin from A. irradians. The cDNA fragment encoding the mature peptide of AiCTL5 was recombined into pET-21a (+) with a C-terminal hexa-histidine tag fused in-frame, and expressed in Escherichia coli Origami (DE3). The recombinant AiCTL5 (rAiCTL5) agglutinated Gram-negative E. coli TOP10F' and Listonella anguillarum, but did not agglutinate Gram-positive bacteria Bacillus thuringiensis and Micrococcus luteus, and the agglutination could be inhibited by EDTA, indicating that AiCTL5 was a Ca(2+)-dependent lectin. rAiCTL5 exhibited a significantly strong activity to bind LPS from E. coli, which conformed to the agglutinating activity toward Gram-negative bacteria. Moreover, rAiCTL5 also agglutinated rabbit erythrocytes. These results indicated that AiCTL5 could function as a pattern recognition receptor to protect bay scallop from Gram-negative bacterial infection, and also provide evidence to understand the structural and functional diverse of lectin. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Short preheating at 41°C leads to a red blood cells count comparable to that in RET channel of Sysmex analysers in samples showing cold agglutination.

    PubMed

    La Gioia, Antonio; Fumi, Maurizio; Fiorini, Fabiana; Pezzati, Paola; Balboni, Fiamma; Bombara, Maria; Marini, Alessandra; Pancione, Ylenia; Solarino, Leonardo; Marchese, Elisa; Sale, Silvia; Rocco, Vincenzo; Fiorini, Marcello

    2018-03-13

    The presence of cold agglutinin in blood samples can cause a spontaneous agglutination of red blood cells (RBCs) when low temperature occurs. This phenomenon causes a spurious lowering of RBC count on the automated haematological analysers that are detected by incongruous values (≥370 g/L) of the mean cellular haemoglobi concentration (MCHC). A preheating at 37°C can remove the RBC agglutination generally resulting in a reliable count. It has been reported that the same result can be reached by using the optical reticulocyte (RET) channel of Sysmex analysers where the RBC count is not influenced by the presence of cold agglutinin. This study aims to evaluate these data in a larger population, with regard to environmental conditions on Sysmex analysers. We have also evaluated the influence of different thermal pretreatments on the RBC count. This study was performed on 96 remnants of peripheral blood samples (48 with MCHC in normal range and 48 with MCHC > 370 g/L) which have been analysed in different preanalytical conditions on the Sysmex analysers. A preheating of samples at 41°C for 1 min leads to a reversibility of the cold agglutination comparable to the one observed in the RET channel and yields better results compared with 37°C for 2 hours. None of described procedures assure the complete cold agglutination reversibility in every case. Consequently, since the haematological analysers not yet provide reliable parameters to confirm the complete resolution of agglutination, further verification of RBC count accuracy needs to be performed. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. A low cost and high throughput magnetic bead-based immuno-agglutination assay in confined droplets.

    PubMed

    Teste, Bruno; Ali-Cherif, Anaïs; Viovy, Jean Louis; Malaquin, Laurent

    2013-06-21

    Although passive immuno-agglutination assays consist of one step and simple procedures, they are usually not adapted for high throughput analyses and they require expensive and bulky equipment for quantitation steps. Here we demonstrate a low cost, multimodal and high throughput immuno-agglutination assay that relies on a combination of magnetic beads (MBs), droplets microfluidics and magnetic tweezers. Antibody coated MBs were used as a capture support in the homogeneous phase. Following the immune interaction, water in oil droplets containing MBs and analytes were generated and transported in Teflon tubing. When passing in between magnetic tweezers, the MBs contained in the droplets were magnetically confined in order to enhance the agglutination rate and kinetics. When releasing the magnetic field, the internal recirculation flows in the droplet induce shear forces that favor MBs redispersion. In the presence of the analyte, the system preserves specific interactions and MBs stay in the aggregated state while in the case of a non-specific analyte, redispersion of particles occurs. The analyte quantitation procedure relies on the MBs redispersion rate within the droplet. The influence of different parameters such as magnetic field intensity, flow rate and MBs concentration on the agglutination performances have been investigated and optimized. Although the immuno-agglutination assay described in this work may not compete with enzyme linked immunosorbent assay (ELISA) in terms of sensitivity, it offers major advantages regarding the reagents consumption (analysis is performed in sub microliter droplet) and the platform cost that yields to very cheap analyses. Moreover the fully automated analysis procedure provides reproducible analyses with throughput well above those of existing technologies. We demonstrated the detection of biotinylated phosphatase alkaline in 100 nL sample volumes with an analysis rate of 300 assays per hour and a limit of detection of 100 pM.

  2. Optimal second order sliding mode control for linear uncertain systems.

    PubMed

    Das, Madhulika; Mahanta, Chitralekha

    2014-11-01

    In this paper an optimal second order sliding mode controller (OSOSMC) is proposed to track a linear uncertain system. The optimal controller based on the linear quadratic regulator method is designed for the nominal system. An integral sliding mode controller is combined with the optimal controller to ensure robustness of the linear system which is affected by parametric uncertainties and external disturbances. To achieve finite time convergence of the sliding mode, a nonsingular terminal sliding surface is added with the integral sliding surface giving rise to a second order sliding mode controller. The main advantage of the proposed OSOSMC is that the control input is substantially reduced and it becomes chattering free. Simulation results confirm superiority of the proposed OSOSMC over some existing. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  3. Projective synchronization of nonidentical fractional-order neural networks based on sliding mode controller.

    PubMed

    Ding, Zhixia; Shen, Yi

    2016-04-01

    This paper investigates global projective synchronization of nonidentical fractional-order neural networks (FNNs) based on sliding mode control technique. We firstly construct a fractional-order integral sliding surface. Then, according to the sliding mode control theory, we design a sliding mode controller to guarantee the occurrence of the sliding motion. Based on fractional Lyapunov direct methods, system trajectories are driven to the proposed sliding surface and remain on it evermore, and some novel criteria are obtained to realize global projective synchronization of nonidentical FNNs. As the special cases, some sufficient conditions are given to ensure projective synchronization of identical FNNs, complete synchronization of nonidentical FNNs and anti-synchronization of nonidentical FNNs. Finally, one numerical example is given to demonstrate the effectiveness of the obtained results. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Zooming in: high resolution 3D reconstruction of differently stained histological whole slide images

    NASA Astrophysics Data System (ADS)

    Lotz, Johannes; Berger, Judith; Müller, Benedikt; Breuhahn, Kai; Grabe, Niels; Heldmann, Stefan; Homeyer, André; Lahrmann, Bernd; Laue, Hendrik; Olesch, Janine; Schwier, Michael; Sedlaczek, Oliver; Warth, Arne

    2014-03-01

    Much insight into metabolic interactions, tissue growth, and tissue organization can be gained by analyzing differently stained histological serial sections. One opportunity unavailable to classic histology is three-dimensional (3D) examination and computer aided analysis of tissue samples. In this case, registration is needed to reestablish spatial correspondence between adjacent slides that is lost during the sectioning process. Furthermore, the sectioning introduces various distortions like cuts, folding, tearing, and local deformations to the tissue, which need to be corrected in order to exploit the additional information arising from the analysis of neighboring slide images. In this paper we present a novel image registration based method for reconstructing a 3D tissue block implementing a zooming strategy around a user-defined point of interest. We efficiently align consecutive slides at increasingly fine resolution up to cell level. We use a two-step approach, where after a macroscopic, coarse alignment of the slides as preprocessing, a nonlinear, elastic registration is performed to correct local, non-uniform deformations. Being driven by the optimization of the normalized gradient field (NGF) distance measure, our method is suitable for differently stained and thus multi-modal slides. We applied our method to ultra thin serial sections (2 μm) of a human lung tumor. In total 170 slides, stained alternately with four different stains, have been registered. Thorough visual inspection of virtual cuts through the reconstructed block perpendicular to the cutting plane shows accurate alignment of vessels and other tissue structures. This observation is confirmed by a quantitative analysis. Using nonlinear image registration, our method is able to correct locally varying deformations in tissue structures and exceeds the limitations of globally linear transformations.

  5. The Introduction of Crystallographic Concepts Using Lap-Dissolve Slide Techniques.

    ERIC Educational Resources Information Center

    Bodner, George M.; And Others

    1980-01-01

    Describes a method using lap-dissolve slide techniques with two or more slide projectors focused on a single screen for presenting visual effects that show structural features in extended arrays of atoms, or ions involving up to several hundred atoms. Presents an outline of an introduction to the structures of crystalline solids. (CS)

  6. Measuring the Photocatalytic Breakdown of Crystal Violet Dye using a Light Emitting Diode Approach

    NASA Technical Reports Server (NTRS)

    Ryan, Robert E.; Underwood, Lauren W.; O'Neal, Duane; Pagnutti, Mary; Davis, Bruce A.

    2009-01-01

    A simple method to estimate the photocatalytic reactivity performance of spray-on titanium dioxide coatings for transmissive glass surfaces was developed. This novel technique provides a standardized method to evaluate the efficiency of photocatalytic material systems over a variety of illumination levels. To date, photocatalysis assessments have generally been conducted using mercury black light lamps. Illumination levels for these types of lamps are difficult to vary, consequently limiting their use for assessing material performance under a diverse range of simulated environmental conditions. This new technique uses an ultraviolet (UV) gallium nitride (GaN) light emitting diode (LED) array instead of a traditional black light to initiate and sustain photocatalytic breakdown. This method was tested with a UV-resistant dye (crystal violet) applied to a titanium dioxide coated glass slide. Experimental control is accomplished by applying crystal violet to both titanium dioxide coated slides and uncoated control slides. A slide is illuminated by the UV LED array, at various light levels representative of outdoor and indoor conditions, from the dye side of the slide. To monitor degradation of the dye over time, a temperature-stabilized white light LED, whose emission spectrum overlaps with the dye absorption spectrum, is used to illuminate the opposite side of the slide. Using a spectrometer, the amount of light from the white light LED transmitted through the slide as the dye degrades is monitored as a function of wavelength and time and is subsequently analyzed. In this way, the rate of degradation for photocatalytically coated versus uncoated slide surfaces can be compared. Results demonstrate that the dye absorption decreased much more rapidly on the photocatalytically coated slides than on the control uncoated slides, and that dye degradation is dependent on illumination level. For photocatalytic activity assessment purposes, this experimental configuration and methodology minimizes many external variable effects and enables small changes in absorption to be measured. This research also compares the advantages of this innovative LED light source design over traditional mercury black light systems and non- LED lamp approaches. This novel technology begins to address the growing need for a standard method that can assess the performance of photocatalytic materials before deployment for large scale, real world use.

  7. Sliding window prior data assisted compressed sensing for MRI tracking of lung tumors.

    PubMed

    Yip, Eugene; Yun, Jihyun; Wachowicz, Keith; Gabos, Zsolt; Rathee, Satyapal; Fallone, B G

    2017-01-01

    Hybrid magnetic resonance imaging and radiation therapy devices are capable of imaging in real-time to track intrafractional lung tumor motion during radiotherapy. Highly accelerated magnetic resonance (MR) imaging methods can potentially reduce system delay time and/or improves imaging spatial resolution, and provide flexibility in imaging parameters. Prior Data Assisted Compressed Sensing (PDACS) has previously been proposed as an acceleration method that combines the advantages of 2D compressed sensing and the KEYHOLE view-sharing technique. However, as PDACS relies on prior data acquired at the beginning of a dynamic imaging sequence, decline in image quality occurs for longer duration scans due to drifts in MR signal. Novel sliding window-based techniques for refreshing prior data are proposed as a solution to this problem. MR acceleration is performed by retrospective removal of data from the fully sampled sets. Six patients with lung tumors are scanned with a clinical 3 T MRI using a balanced steady-state free precession (bSSFP) sequence for 3 min at approximately 4 frames per second, for a total of 650 dynamics. A series of distinct pseudo-random patterns of partial k-space acquisition is generated such that, when combined with other dynamics within a sliding window of 100 dynamics, covers the entire k-space. The prior data in the sliding window are continuously refreshed to reduce the impact of MR signal drifts. We intended to demonstrate two different ways to utilize the sliding window data: a simple averaging method and a navigator-based method. These two sliding window methods are quantitatively compared against the original PDACS method using three metrics: artifact power, centroid displacement error, and Dice's coefficient. The study is repeated with pseudo 0.5 T images by adding complex, normally distributed noise with a standard deviation that reduces image SNR, relative to original 3 T images, by a factor of 6. Without sliding window implemented, PDACS-reconstructed dynamic datasets showed progressive increases in image artifact power as the 3 min scan progresses. With sliding windows implemented, this increase in artifact power is eliminated. Near the end of a 3 min scan at 3 T SNR and 5× acceleration, implementation of an averaging (navigator) sliding window method improves our metrics by the following ways: artifact power decreases from 0.065 without sliding window to 0.030 (0.031), centroid error decreases from 2.64 to 1.41 mm (1.28 mm), and Dice coefficient agreement increases from 0.860 to 0.912 (0.915). At pseudo 0.5 T SNR, the improvements in metrics are as follows: artifact power decreases from 0.110 without sliding window to 0.0897 (0.0985), centroid error decreases from 2.92 mm to 1.36 mm (1.32 mm), and Dice coefficient agreements increases from 0.851 to 0.894 (0.896). In this work we demonstrated the negative impact of slow changes in MR signal for longer duration PDACS dynamic scans, namely increases in image artifact power and reductions of tumor tracking accuracy. We have also demonstrated sliding window implementations (i.e., refreshing of prior data) of PDACS are effective solutions to this problem at both 3 T and simulated 0.5 T bSSFP images. © 2016 American Association of Physicists in Medicine.

  8. Performance of residents using digital images versus glass slides on certification examination in anatomical pathology: a mixed methods pilot study

    PubMed Central

    Mirham, Lorna; Naugler, Christopher; Hayes, Malcolm; Ismiil, Nadia; Belisle, Annie; Sade, Shachar; Streutker, Catherine; MacMillan, Christina; Rasty, Golnar; Popovic, Snezana; Joseph, Mariamma; Gabril, Manal; Barnes, Penny; Hegele, Richard G.; Carter, Beverley; Yousef, George M.

    2016-01-01

    Background: It is anticipated that many licensing examination centres for pathology will begin fully digitizing the certification examinations. The objective of our study was to test the feasibility of a fully digital examination and to assess the needs, concerns and expectations of pathology residents in moving from a glass slide-based examination to a fully digital examination. Methods: We conducted a mixed methods study that compared, after randomization, the performance of senior residents (postgraduate years 4 and 5) in 7 accredited anatomical pathology training programs across Canada on a pathology examination using either glass slides or digital whole-slide scanned images of the slides. The pilot examination was followed by a post-test survey. In addition, pathology residents from all levels of training were invited to participate in an online survey. Results: A total of 100 residents participated in the pilot examination; 49 were given glass slides instead of digital images. We found no significant difference in examination results between the 2 groups of residents (estimated marginal mean 8.23/12, 95% confidence interval [CI] 7.72-8.87, for glass slides; 7.84/12, 95% CI 7.28-8.41, for digital slides). In the post-test survey, most of the respondents expressed concerns with the digital examination, including slowly functioning software, blurring and poor detail of images, particularly nuclear features. All of the respondents of the general survey (n = 179) agreed that additional training was required if the examination were to become fully digital. Interpretation: Although the performance of residents completing pathology examinations with glass slides was comparable to that of residents using digital images, our study showed that residents were not comfortable with the digital technology, especially given their current level of exposure to it. Additional training may be needed before implementing a fully digital examination, with consideration for a gradual transition. PMID:27280119

  9. Sliding mode control method having terminal convergence in finite time

    NASA Technical Reports Server (NTRS)

    Venkataraman, Subramanian T. (Inventor); Gulati, Sandeep (Inventor)

    1994-01-01

    An object of this invention is to provide robust nonlinear controllers for robotic operations in unstructured environments based upon a new class of closed loop sliding control methods, sometimes denoted terminal sliders, where the new class will enforce closed-loop control convergence to equilibrium in finite time. Improved performance results from the elimination of high frequency control switching previously employed for robustness to parametric uncertainties. Improved performance also results from the dependence of terminal slider stability upon the rate of change of uncertainties over the sliding surface rather than the magnitude of the uncertainty itself for robust control. Terminal sliding mode control also yields improved convergence where convergence time is finite and is to be controlled. A further object is to apply terminal sliders to robot manipulator control and benchmark performance with the traditional computed torque control method and provide for design of control parameters.

  10. Georadar and geoelectricity method to identify the determine zone of sliding landslide

    NASA Astrophysics Data System (ADS)

    Dalimunthe, Y. K.; Hamid, A.

    2018-01-01

    The aim of this research is to determine the contrast between the sliding plane by observing the parameters of rock types, fractures, and faults that could potentially land slides in Bandar Baru, Lampung Barat, Indonesia by both methods of georadar and geoelectricity. This research uses radar reflection profiling configuration for georadar and dipole-dipole configuration for geoelectricity. For georadar data processing has been done with Reflexwave software and for geoelectricity, data processing has been done with Earthimager 2DINV software to interpret subsurface section. Results of research by both methods of georadar and geoelectricity shows the area of contact between the sand stone with resistivity value of 200-1449 Ωm and clay stone with a resistivity value of 32-100 Ωm at the limit depth of 9 m as a potential zone of sliding landslides where the physical properties of clay stone easily derail massive material on it.

  11. Robust sliding mode control applied to double Inverted pendulum system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mahjoub, Sonia; Derbel, Nabil; Mnif, Faical

    A three hierarchical sliding mode control is presented for a class of an underactuated system which can overcome the mismatched perturbations. The considered underactuated system is a double inverted pendulum (DIP), can be modeled by three subsystems. Such structure allows the construction of several designs of hierarchies for the controller. For all hierarchical designs, the asymptotic stability of every layer sliding mode surface and the sliding mode surface of subsystems are proved theoretically by Barbalat's lemma. Simulation results show the validity of these methods.

  12. Isolation and characterization of Escherichia coli pili from diverse clinical sources.

    PubMed

    Salit, I E; Vavougios, J; Hofmann, T

    1983-11-01

    Bacteria which attach to different mucous membranes should have differing specificities of adherence in vitro. Human Escherichia coli isolates from blood and urine (pathogens) and from stool and throat (commensals) were characterized as to the patterns of hemagglutination (HA), as well as the structure and function of their pili. Bacterial HA was done in microtiter plates and on slides after bacterial growth in broth or agar. Human erythrocytes were agglutinated by 95% of the pathogens and 65 to 70% of the commensals grown in broth or agar. Mannose-resistant HA was characteristically caused by pathogens, and commensals characteristically caused mannose-sensitive HA of guinea pig cells. Strains often had both mannose-resistant and mannose-sensitive reactions, or even a mannose-paradoxical reaction. Pathogens more often caused HA, but titers were lower than those for commensals. Slide HA was less sensitive than the microtiter method. All isolates were piliated. Commensals also had more pili than pathogens when grown in broth (117.8 versus 38.3 pili per bacterium), but pathogens had more pili after growth on agar (32.1 versus 8.1 pili per bacterium). Isolates causing high-titer HA had large numbers of pili (greater than 85 pili per bacterium), but some well-piliated strains were non-hemagglutinating. Pili were purified from seven E. coli strains from different sites of isolation and with different erythrocyte-binding specificity. Pili usually migrated as a single band on sodium dodecyl sulfate-polyacrylamide gel electrophoresis. However, more than one type of pilus could be copurified from some strains since there were two or more bands after separation in octyl-glucoside and two different amino terminal sequences. Protein sequencing was done on five different pili: four resembled type 1 pili and one was a P fimbria. The type 1-like pili (strains 2239 and 9353) had an initial variable sequence of 1 to 5 residues, followed by a common region of 21 residues. The P fimbria (strain 7714) had different erythrocyte-binding specificity but was still 27% homologous with 2239 and 9353. E. coli strains from different body sites have characteristic attachments to erythrocytes. Pili derived from these different sources may also have different binding specificity, but they are similar in primary structure.

  13. Isolation and characterization of Escherichia coli pili from diverse clinical sources.

    PubMed Central

    Salit, I E; Vavougios, J; Hofmann, T

    1983-01-01

    Bacteria which attach to different mucous membranes should have differing specificities of adherence in vitro. Human Escherichia coli isolates from blood and urine (pathogens) and from stool and throat (commensals) were characterized as to the patterns of hemagglutination (HA), as well as the structure and function of their pili. Bacterial HA was done in microtiter plates and on slides after bacterial growth in broth or agar. Human erythrocytes were agglutinated by 95% of the pathogens and 65 to 70% of the commensals grown in broth or agar. Mannose-resistant HA was characteristically caused by pathogens, and commensals characteristically caused mannose-sensitive HA of guinea pig cells. Strains often had both mannose-resistant and mannose-sensitive reactions, or even a mannose-paradoxical reaction. Pathogens more often caused HA, but titers were lower than those for commensals. Slide HA was less sensitive than the microtiter method. All isolates were piliated. Commensals also had more pili than pathogens when grown in broth (117.8 versus 38.3 pili per bacterium), but pathogens had more pili after growth on agar (32.1 versus 8.1 pili per bacterium). Isolates causing high-titer HA had large numbers of pili (greater than 85 pili per bacterium), but some well-piliated strains were non-hemagglutinating. Pili were purified from seven E. coli strains from different sites of isolation and with different erythrocyte-binding specificity. Pili usually migrated as a single band on sodium dodecyl sulfate-polyacrylamide gel electrophoresis. However, more than one type of pilus could be copurified from some strains since there were two or more bands after separation in octyl-glucoside and two different amino terminal sequences. Protein sequencing was done on five different pili: four resembled type 1 pili and one was a P fimbria. The type 1-like pili (strains 2239 and 9353) had an initial variable sequence of 1 to 5 residues, followed by a common region of 21 residues. The P fimbria (strain 7714) had different erythrocyte-binding specificity but was still 27% homologous with 2239 and 9353. E. coli strains from different body sites have characteristic attachments to erythrocytes. Pili derived from these different sources may also have different binding specificity, but they are similar in primary structure. Images PMID:6139339

  14. The Classroom-Friendly ABO Blood Types Kit: Blood Agglutination Simulation

    ERIC Educational Resources Information Center

    Arnold, Savittree Rochanasmita; Kruatong, Tussatrin; Dahsah, Chanyah; Suwanjinda, Duongdearn

    2012-01-01

    The classroom-friendly ABO blood type kit was developed by combining advantages of modelling and a simulation laboratory to teach the topics of ABO blood types and blood transfusion. Teachers can easily simulate the agglutination reaction on a blood type testing plate in the classroom, and show the students how this reaction occurs by using the…

  15. GENETIC ANALYSIS OF THE AGGA LOCUS INVOLVED IN AGGLUTINATION ND ADHERENCE OF PSEUDOMONAS PUTIDA, A BENEFICIAL FLUORESCENT PSEUDOMONAD

    EPA Science Inventory

    An isolate of Pseudomonas putida, which rapidly adheres to plant roots is agglutinated by a glycoprotein from root surfaces. gglutination is presented and adherence to the root surface is diminished by Tn5 insertion in mutant 5123. wo cosmid clones from wild type P putida and 2.7...

  16. Synthesis for Lunar Simulants: Glass, Agglutinate, Plagioclase, Breccia

    NASA Technical Reports Server (NTRS)

    Weinstein, Michael; Wilson, Stephen A.; Rickman, Douglas L.; Stoeser, Douglas

    2012-01-01

    The video describes a process for making glass for lunar regolith simulants that was developed from a patented glass-producing technology. Glass composition can be matched to simulant design and specification. Production of glass, pseudo agglutinates, plagioclase, and breccias is demonstrated. The system is capable of producing hundreds of kilograms of high quality glass and simulants per day.

  17. Lead isotopic studies of lunar soils - Their bearing on the time scale of agglutinate formation

    NASA Technical Reports Server (NTRS)

    Church, S. E.; Tilton, G. R.; Chen, J. H.

    1976-01-01

    Fines (smaller than 75 microns) and bulk soil were studied to analyze loss of volatile lead; losses of the order of 10% to 30% radiogenic lead during the production of agglutinates are assessed. Lead isotope data from fine-agglutinate pairs are analyzed for information on the time scale of micrometeorite bombardment, from the chords generated by the data in concordia diagrams. Resulting mean lead loss ages were compared to spallogenic gas exposure ages for all samples. Labile parentless radiogenic Pb residing preferentially on or in the fines is viewed as possibly responsible for aberrant lead loss ages. Bulk soils plot above the concordia curve (in a field of excess radiogenic Pb) for all samples with anomalous ages.

  18. Use of RBC-O and S-MCV parameters of SYSMEX XE-2100 in a patient with RBC cold agglutination.

    PubMed

    Wang, Hong; Lu, Lin; Zhou, Yun; Liu, Jian; Qian, Min; Tang, Weiming; Jie, Zhang; Pan, Shiyang

    2013-01-01

    Sometimes EDTA blood of erythrocyte agglutination cannot be well resolved by incubation at 37 degrees C. In this case report, however, such a specimen was detected from a lymphoma patient at room temperature by using RBC-O and S-MCV parameters of the SYSMEX XE-2100 hematology analyzer. The specimen was diluted with 0.9% NaCL solution at 1:1 before measurement. HCT, MCV, and MCHC, corrected by RBC-O, HGB and S-MCV, were all in their normal ranges. This case indicates that RBC-O and S-MCV parameters of XE-2100 can be used in the routine blood examination of erythrocyte agglutination specimen at room temperature.

  19. [Preparation and characterization of follwing the national standard anti-Brucella abortus serum, bovine].

    PubMed

    Li, Cui; Guan, Fushi; Dai, Zhihong; Jiang, Hui; Wen, Fang; Lu, Lianshou; Wang, Zaishi

    2011-05-01

    To prepare anti-Brucella abortus serum used for calibrate the agglutination test follwing the national standard, 4 anti-Brucella abortus sera were obtained from 4 cows infected with Brucella abortus naturally. By potency testing, the third serum was selected. Sterility, vaccum degree, residual moisture, uniformity and stability of this standard material were tested and proved to meet the national standard. Referring to the international standard, RBT (Rose-Bengal plate agglutination test), SAT (standard tube agglutination) and CFT (complement fixation test) titers of this standard material were measured to be 1:160 "+" 1:2 400 "++" and 1:800 "++", which are identical with the collaborative assay results. International unit of the standard material is 4 000 IU/mL.

  20. Recycled grains in lunar soils as an additional, necessary, regolith evolution parameter

    NASA Technical Reports Server (NTRS)

    Basu, A.

    1990-01-01

    Recycled lunar soil grains are defined as those soil grains that have been a part of either regolith breccias or agglutinates; thus, mineral grains, rock fragments, older agglutinates, and volcanic glass spherules, if dislodged from an agglutinate or a regolith breccia, would all qualify as recycled grains. This paper shows that it is possible to estimate the proportion of recycled material in lunar soils. Optical data from 12 soils in the Apollo 16 core 64001/2 were collected to estimate the proportion (W) of recycled crystalline grains in each of these soils. The W values show a correspondence with other independently derived parameters and the history of the core soils, indicating that W can be used as a valid soil-evolution parameter.

  1. Sequence-dependent nucleosome sliding in rotation-coupled and uncoupled modes revealed by molecular simulations

    PubMed Central

    Tan, Cheng; Takada, Shoji

    2017-01-01

    While nucleosome positioning on eukaryotic genome play important roles for genetic regulation, molecular mechanisms of nucleosome positioning and sliding along DNA are not well understood. Here we investigated thermally-activated spontaneous nucleosome sliding mechanisms developing and applying a coarse-grained molecular simulation method that incorporates both long-range electrostatic and short-range hydrogen-bond interactions between histone octamer and DNA. The simulations revealed two distinct sliding modes depending on the nucleosomal DNA sequence. A uniform DNA sequence showed frequent sliding with one base pair step in a rotation-coupled manner, akin to screw-like motions. On the contrary, a strong positioning sequence, the so-called 601 sequence, exhibits rare, abrupt transitions of five and ten base pair steps without rotation. Moreover, we evaluated the importance of hydrogen bond interactions on the sliding mode, finding that strong and weak bonds favor respectively the rotation-coupled and -uncoupled sliding movements. PMID:29194442

  2. A new optimal sliding mode controller design using scalar sign function.

    PubMed

    Singla, Mithun; Shieh, Leang-San; Song, Gangbing; Xie, Linbo; Zhang, Yongpeng

    2014-03-01

    This paper presents a new optimal sliding mode controller using the scalar sign function method. A smooth, continuous-time scalar sign function is used to replace the discontinuous switching function in the design of a sliding mode controller. The proposed sliding mode controller is designed using an optimal Linear Quadratic Regulator (LQR) approach. The sliding surface of the system is designed using stable eigenvectors and the scalar sign function. Controller simulations are compared with another existing optimal sliding mode controller. To test the effectiveness of the proposed controller, the controller is implemented on an aluminum beam with piezoceramic sensor and actuator for vibration control. This paper includes the control design and stability analysis of the new optimal sliding mode controller, followed by simulation and experimental results. The simulation and experimental results show that the proposed approach is very effective. © 2013 ISA. Published by Elsevier Ltd. All rights reserved.

  3. Measuring Glial Metabolism in Repetitive Brain Trauma and Alzheimer’s Disease

    DTIC Science & Technology

    2016-09-01

    Six methods: Single value decomposition (SVD), wavelet, sliding window, sliding window with Gaussian weighting, spline and spectral improvements...comparison of a range of different denoising methods for dynamic MRS. Six denoising methods were considered: Single value decomposition (SVD), wavelet...project by improving the software required for the data analysis by developing six different denoising methods. He also assisted with the testing

  4. QUANTITATIVE ASPECTS OF THE RED BLOOD CELL AGGLUTINATION TEST FOR INFLUENZA VIRUS

    PubMed Central

    Miller, Gail Lorenz; Stanley, W. M.

    1944-01-01

    A detailed study has been made of the nature of the variables inherent in the chicken red cell agglutination test for influenza virus in an effort to obtain a method of measurement of biological activity of sufficient accuracy that it might be employed as a reliable index of chemical purity of preparations of the virus. It was found that the temperature at which the test is conducted has a marked effect on the titer, whereas within the range of pH 6–8 the pH has a negligible effect. It was also found that a variation in results may be encountered due to a variation in the specific behavior of red cells from different chickens and to an instability of the red cells themselves. Preparations of purified influenza virus held at 4°C., on the other hand, were found to be stable with respect to chicken red cell agglutinating activity for several months. This fact, together with the fact that in duplicate measurements upon different samples the accuracy was such that the chances were 19 out of 20 that differences of 8.4 per cent in the mean end points were significant, made it possible to establish a reproducible standard of CCA activity based on a unit weight of purified virus material. As a result, it was possible to devise a standardized procedure for carrying out with high accuracy quantitative measurements of influenza virus. PMID:19871362

  5. On the numerical modeling of sliding beams: A comparison of different approaches

    NASA Astrophysics Data System (ADS)

    Steinbrecher, Ivo; Humer, Alexander; Vu-Quoc, Loc

    2017-11-01

    The transient analysis of sliding beams represents a challenging problem of structural mechanics. Typically, the sliding motion superimposed by large flexible deformation requires numerical methods as, e.g., finite elements, to obtain approximate solutions. By means of the classical sliding spaghetti problem, the present paper provides a guideline to the numerical modeling with conventional finite element codes. For this purpose, two approaches, one using solid elements and one using beam elements, respectively, are employed in the analysis, and the characteristics of each approach are addressed. The contact formulation realizing the interaction of the beam with its support demands particular attention in the context of sliding structures. Additionally, the paper employs the sliding-beam formulation as a third approach, which avoids the numerical difficulties caused by the large sliding motion through a suitable coordinate transformation. The present paper briefly outlines the theoretical fundamentals of the respective approaches for the modeling of sliding structures and gives a detailed comparison by means of the sliding spaghetti serving as a representative example. The specific advantages and limitations of the different approaches with regard to accuracy and computational efficiency are discussed in detail. Through the comparison, the sliding-beam formulation, which proves as an effective approach for the modeling, can be validated for the general problem of a sliding structure subjected to large deformation.

  6. [Construction of the DNA vaccine of major outer membrane protein of Neisseria gonorrhoeae and investigation of immune effects after vaccination].

    PubMed

    Liao, Fang; He, Chao; Liu, Hai-Peng; Song, Qi-Fa; Yan, Jie

    2006-11-01

    To clone PIB gene of Neisseria gonorrhoeae, and to construct a recombinant eukaryotic expression vector pCI-PIB and to understand the effects of pCI-PIB vaccination in mice to induce specific humoral and cellular immune responses. The entire PIB gene of Neisseria gonorrhoeae (960 bp) was amplified by using PCR. An eukaryotic eukaryotic vector pCI-PIB was then constructed. BALB/c mice (n = 65, 100 microg/time/mouse) were immunized with pCI-PIB by intramuscular injection. ABC assay was employed to examine the PIB expression in muscular cells of the pCI-PIB-immunized mice (n = 10). ELISA and MTT assays were used to measure the effects of humoral and cellular immune responses of the remaining pCI-PIB-immunized mice. By using slide agglutination test and complement bacteriolytic test, the serum anti-bacterial activity of the pCI-PIB immunized mice was determined. The entire PIB gene amplification fragment of the expected size (960 bp) was successfully obtained by PCR. In comparison with the reported PIB gene sequence (GenBank No: AF090801), the homology of nucleotide sequence of the target inserted fragment in the recombinant plasmid pCI-PIB was as high as 99.28%. The muscular cells of the immunized mice could take in pCI-PIB and then express PIB. In the pCI-PIB immunized mice, the higher titer (1:4000) of specific serum IgG and the specific T lymphocyte response were found. The proliferation index (4.031) was significantly higher than that of the controls (1.127) (t = 71.71, P < 0.05). The sera and washings from the pCI-PIB immunized mice could agglutinate Neisseria gonorrhoeae and kill this microbe in presence of complements. In this study we successfully constructed a recombinant eukaryotic expression vector pCI-PIB. The mice inoculated with pCI-PIB might efficiently produce the specific humoral and cellular immune responses, suggesting that pCI-PIB should be potential service as a candidate of Neisseria gonorrhoeae DNA vaccines.

  7. Effective classification of the prevalence of Schistosoma mansoni.

    PubMed

    Mitchell, Shira A; Pagano, Marcello

    2012-12-01

    To present an effective classification method based on the prevalence of Schistosoma mansoni in the community. We created decision rules (defined by cut-offs for number of positive slides), which account for imperfect sensitivity, both with a simple adjustment of fixed sensitivity and with a more complex adjustment of changing sensitivity with prevalence. To reduce screening costs while maintaining accuracy, we propose a pooled classification method. To estimate sensitivity, we use the De Vlas model for worm and egg distributions. We compare the proposed method with the standard method to investigate differences in efficiency, measured by number of slides read, and accuracy, measured by probability of correct classification. Modelling varying sensitivity lowers the lower cut-off more significantly than the upper cut-off, correctly classifying regions as moderate rather than lower, thus receiving life-saving treatment. The classification method goes directly to classification on the basis of positive pools, avoiding having to know sensitivity to estimate prevalence. For model parameter values describing worm and egg distributions among children, the pooled method with 25 slides achieves an expected 89.9% probability of correct classification, whereas the standard method with 50 slides achieves 88.7%. Among children, it is more efficient and more accurate to use the pooled method for classification of S. mansoni prevalence than the current standard method. © 2012 Blackwell Publishing Ltd.

  8. Sliding mode control of magnetic suspensions for precision pointing and tracking applications

    NASA Technical Reports Server (NTRS)

    Misovec, Kathleen M.; Flynn, Frederick J.; Johnson, Bruce G.; Hedrick, J. Karl

    1991-01-01

    A recently developed nonlinear control method, sliding mode control, is examined as a means of advancing the achievable performance of space-based precision pointing and tracking systems that use nonlinear magnetic actuators. Analytic results indicate that sliding mode control improves performance compared to linear control approaches. In order to realize these performance improvements, precise knowledge of the plant is required. Additionally, the interaction of an estimating scheme and the sliding mode controller has not been fully examined in the literature. Estimation schemes were designed for use with this sliding mode controller that do not seriously degrade system performance. The authors designed and built a laboratory testbed to determine the feasibility of utilizing sliding mode control in these types of applications. Using this testbed, experimental verification of the authors' analyses is ongoing.

  9. Microscopic validation of whole mouse micro-metastatic tumor imaging agents using cryo-imaging and sliding organ image registration

    NASA Astrophysics Data System (ADS)

    Liu, Yiqiao; Zhou, Bo; Qutaish, Mohammed; Wilson, David L.

    2016-03-01

    We created a metastasis imaging, analysis platform consisting of software and multi-spectral cryo-imaging system suitable for evaluating emerging imaging agents targeting micro-metastatic tumor. We analyzed CREKA-Gd in MRI, followed by cryo-imaging which repeatedly sectioned and tiled microscope images of the tissue block face, providing anatomical bright field and molecular fluorescence, enabling 3D microscopic imaging of the entire mouse with single metastatic cell sensitivity. To register MRI volumes to the cryo bright field reference, we used our standard mutual information, non-rigid registration which proceeded: preprocess --> affine --> B-spline non-rigid 3D registration. In this report, we created two modified approaches: mask where we registered locally over a smaller rectangular solid, and sliding organ. Briefly, in sliding organ, we segmented the organ, registered the organ and body volumes separately and combined results. Though sliding organ required manual annotation, it provided the best result as a standard to measure other registration methods. Regularization parameters for standard and mask methods were optimized in a grid search. Evaluations consisted of DICE, and visual scoring of a checkerboard display. Standard had accuracy of 2 voxels in all regions except near the kidney, where there were 5 voxels sliding. After mask and sliding organ correction, kidneys sliding were within 2 voxels, and Dice overlap increased 4%-10% in mask compared to standard. Mask generated comparable results with sliding organ and allowed a semi-automatic process.

  10. Detection of License Plate using Sliding Window, Histogram of Oriented Gradient, and Support Vector Machines Method

    NASA Astrophysics Data System (ADS)

    Astawa, INGA; Gusti Ngurah Bagus Caturbawa, I.; Made Sajayasa, I.; Dwi Suta Atmaja, I. Made Ari

    2018-01-01

    The license plate recognition usually used as part of system such as parking system. License plate detection considered as the most important step in the license plate recognition system. We propose methods that can be used to detect the vehicle plate on mobile phone. In this paper, we used Sliding Window, Histogram of Oriented Gradient (HOG), and Support Vector Machines (SVM) method to license plate detection so it will increase the detection level even though the image is not in a good quality. The image proceed by Sliding Window method in order to find plate position. Feature extraction in every window movement had been done by HOG and SVM method. Good result had shown in this research, which is 96% of accuracy.

  11. A method of mounting multiple otoliths for beam-based microchemical analyses

    USGS Publications Warehouse

    Donohoe, C.J.; Zimmerman, C.E.

    2010-01-01

    Beam-based analytical methods are widely used to measure the concentrations of elements and isotopes in otoliths. These methods usually require that otoliths be individually mounted and prepared to properly expose the desired growth region to the analytical beam. Most analytical instruments, such as LA-ICPMS and ion and electron microprobes, have sample holders that will accept only one to six slides or mounts at a time. We describe a method of mounting otoliths that allows for easy transfer of many otoliths to a single mount after they have been prepared. Such an approach increases the number of otoliths that can be analyzed in a single session by reducing the need open the sample chamber to exchange slides-a particularly time consuming step on instruments that operate under vacuum. For ion and electron microprobes, the method also greatly reduces the number of slides that must be coated with an electrical conductor prior to analysis. In this method, a narrow strip of cover glass is first glued at one end to a standard microscope slide. The otolith is then mounted in thermoplastic resin on the opposite, free end of the strip. The otolith can then be ground and flipped, if needed, by reheating the mounting medium. After otolith preparation is complete, the cover glass is cut with a scribe to free the otolith and up to 20 small otoliths can be arranged on a single petrographic slide. ?? 2010 The Author(s).

  12. The specificity of the cross-reacting antibodies in blood group O sera which produce mixed agglutination

    PubMed Central

    Franks, D.; Liske, Rosemary

    1968-01-01

    γM cross-reacting antibodies in group O sera produce mixed agglutination with secretor buccal cells, but not with non-secretor cells. The mixed agglutination with sera which also contain immune anti-B is produced only with A buccal cells and B indicator red cells, and not with B buccal cells, and is inhibited by B secretor saliva or galactose, but not by A secretor saliva. Mixed agglutination with sera containing immune anti-A is produced only with B buccal cells and A indicator red cells, and is inhibited by A secretor saliva or 2-acetamido-2-deoxygalactose (N-acetyl-D-galactosamine), but not by B secretor saliva. If two sera, one containing immune anti-A and the other containing immune anti-B, are mixed together in equal volumes, mixed agglutination is no longer produced with either A buccal cells (and B indicator red cells) or B buccal cells (and A indicator red cells). These observations are thought to be most readily explicable by the hypothesis that the combining site on the cross-reacting antibody is smaller than on specific anti-A or anti-B, and that it reacts with that part of the antigenic determinant which is common to both A and B antigens. As a consequence of the restricted size of the combining site, it is suggested that cross-reacting antibody will have a lower affinity for A or B antigens than specific anti-A or anti-B does, and competes unsuccessfully with specific anti-A or anti-B for combination with antigen on buccal cells. PMID:5638582

  13. Development of enhancing agglutination reaction using gold nanoparticle for pre-transfusion testing.

    PubMed

    Choktaweesak, N; Krasathong, P; Ammaranond, P

    2016-10-01

    To explore an alternative way for antibody detection testing, the examination of gold nanoparticle solution for enhancing unexpected antibodies for pre-transfusion testing was investigated. Exposure of foreign antigens on red blood cells from transfusion can trigger the immune system to produce unexpected antibodies. This immunological response may cause the complication to future transfusion. For detection of unexpected antibodies, the antibody screening test is performed approximately 30-60 min. To reduce turnaround time, enhancing reagent, low-ionic strength solution (LISS), is widely used. However, cost of enhancing reagent is an issue which has concerned in resource limited countries. Gold nanoparticle solution can increase red blood cells agglutination reaction. To solve this issue, study of gold nanoparticle solution was investigated. Samples were performed comparing between LISS and gold nanoparticle solution at antiglobulin phase. After reading the agglutination reaction, supernatants were collected and measured at the optical density at 760 nm by spectrophotometer. The optical density in the tube of gold nanoparticle solution was higher than in the tube of 2-5% cell suspension and monoclonal antibody. It has been observed that gold nanoparticle solution enhanced the reaction of agglutination 98% while LISS enhanced the agglutination only 60·8%. Employing a commercially available enhancing reagent, parallel samples confirmed results providing validation of the assay. It approximately costs $1 US dollars compared to $30 for a commercially available reagent. The low cost and yet effective time-consuming test for antibody screening is a practical and viable solution alternative way for performing in antibody screening test in resource limited countries. © 2016 British Blood Transfusion Society.

  14. Studies on allergenic algae of Delhi area: botanical aspects.

    PubMed

    Mittal, A; Agarwal, M K; Shivpuri, D N

    1979-04-01

    To study distribution of algae in and around Delhi aerobiological surveys were undertaken for two consecutive years (September, 1972, to August, 1974). The surveys were accomplished by (a) slide exposure method and (b) culture plate exposure method. A total of 850 slides were exposed using Durham's gravity sampling device. Of these, 560 slides were exposed during 1973 (272 slides at two meter and 288 at ten meter height) and the rest (290 slides) were exposed during 1974 at ten meter height. A total of 858 culture plates were exposed (276 for one hour and 282 for two hours) during 1973 and the rest (300 culture plates) were exposed during 1974 at ten meter height for two hours duration only. Air was found to be rich in algae flora during the months of September to November. The dominant forms of algae present were all blue greens. This might be due to the relative greater resistance of blue green algae to unfavorable conditions.

  15. Bayesian estimation of sensitivity and specificity of the modified agglutination test and bioassay for detection of Toxoplasma gondii in free-range chickens

    USDA-ARS?s Scientific Manuscript database

    Toxoplasma gondii infects virtually all warm-blooded animals worldwide. Serological tests, including the modified agglutination test (MAT), are often used to determine exposure to the parasite. The MAT can be used for all hosts because it does not need species-specific reagents and has been shown to...

  16. Rapid detection of hepatitis B virus surface antigen by an agglutination assay mediated by a bispecific diabody against both human erythrocytes and hepatitis B virus surface antigen.

    PubMed

    Chen, Yu-Ping; Qiao, Yuan-Yuan; Zhao, Xiao-Hang; Chen, Hong-Song; Wang, Yan; Wang, Zhuozhi

    2007-06-01

    Bispecific antibodies have immense potential for use in clinical applications. In the present study, a bispecific diabody against human red blood cells (RBCs) and hepatitis B virus surface antigen (HBsAg) was used to detect HBsAg in blood specimens. The bispecific diabody was constructed by crossing over the variable region of the heavy chains and the light chains of anti-RBC and anti-HBsAg antibodies with a short linker, SRGGGS. In enzyme-linked immunosorbent assays, this bispecific diabody showed specific binding to both RBCs and HBsAg. When this bispecific diabody was mixed with human blood specimens in the presence of HBsAg, the dual binding sites of the diabody caused agglutination of human RBCs. This diabody-mediated agglutination assay was then used to test 712 clinical blood specimens and showed 97.7% sensitivity and 100% specificity when the results were compared with those of the conventional immunoassay, which was used as a reference. This autologous RBC agglutination assay provides a simple approach for rapid screening for HBsAg in blood specimens.

  17. Rapid Detection of Hepatitis B Virus Surface Antigen by an Agglutination Assay Mediated by a Bispecific Diabody against Both Human Erythrocytes and Hepatitis B Virus Surface Antigen▿

    PubMed Central

    Chen, Yu-Ping; Qiao, Yuan-Yuan; Zhao, Xiao-Hang; Chen, Hong-Song; Wang, Yan; Wang, Zhuozhi

    2007-01-01

    Bispecific antibodies have immense potential for use in clinical applications. In the present study, a bispecific diabody against human red blood cells (RBCs) and hepatitis B virus surface antigen (HBsAg) was used to detect HBsAg in blood specimens. The bispecific diabody was constructed by crossing over the variable region of the heavy chains and the light chains of anti-RBC and anti-HBsAg antibodies with a short linker, SRGGGS. In enzyme-linked immunosorbent assays, this bispecific diabody showed specific binding to both RBCs and HBsAg. When this bispecific diabody was mixed with human blood specimens in the presence of HBsAg, the dual binding sites of the diabody caused agglutination of human RBCs. This diabody-mediated agglutination assay was then used to test 712 clinical blood specimens and showed 97.7% sensitivity and 100% specificity when the results were compared with those of the conventional immunoassay, which was used as a reference. This autologous RBC agglutination assay provides a simple approach for rapid screening for HBsAg in blood specimens. PMID:17442848

  18. Age-Related Buildup of Humoral Immunity against Epitopes for Rosette Formation and Agglutination in African Areas of Malaria Endemicity

    PubMed Central

    Barragan, Antonio; Kremsner, Peter G.; Weiss, Walter; Wahlgren, Mats; Carlson, Johan

    1998-01-01

    In this report, we show an age-related buildup of agglutinating activity as well as serum activity against rosette formation in children living in areas of Kenya and Gabon where malaria is endemic. Sera from Kenyans in general exhibited a stronger and wider immune response toward the epitopes, probably reflecting a difference in transmission patterns between the two areas. Thus, our results indicate that repeated malaria attacks in areas of endemicity, and consequently exposure to different isolate-specific antigens, will elicit an antibody-mediated response eventually enabling recognition of the majority of rosetting and agglutinating antigens. The correlation between antirosetting and agglutinating capacity was poor in individual cases, indicating that the rosetting epitopes are only a minor part of the highly diverse surface-exposed antigens (mainly PfEMP1) on the surface of parasitized erythrocytes toward which antibodies may react. These data together with our previous findings that the protection against cerebral malaria correlates with presence of antirosetting antibodies shed new light on our understanding of the gradual acquisition of immunity toward severe complications of malarial infection which children reared in areas of endemicity attain. PMID:9746579

  19. Relationships between host body condition and immunocompetence, not host sex, best predict parasite burden in a bat-helminth system.

    PubMed

    Warburton, Elizabeth M; Pearl, Christopher A; Vonhof, Maarten J

    2016-06-01

    Sex-biased parasitism highlights potentially divergent approaches to parasite resistance resulting in differing energetic trade-offs for males and females; however, trade-offs between immunity and self-maintenance could also depend on host body condition. We investigated these relationships in the big brown bat, Eptesicus fuscus, to determine if host sex or body condition better predicted parasite resistance, if testosterone levels predicted male parasite burdens, and if immune parameters could predict male testosterone levels. We found that male and female hosts had similar parasite burdens and female bats scored higher than males in only one immunological measure. Top models of helminth burden revealed interactions between body condition index and agglutination score as well as between agglutination score and host sex. Additionally, the strength of the relationships between sex, agglutination, and helminth burden is affected by body condition. Models of male parasite burden provided no support for testosterone predicting helminthiasis. Models that best predicted testosterone levels did not include parasite burden but instead consistently included month of capture and agglutination score. Thus, in our system, body condition was a more important predictor of immunity and worm burden than host sex.

  20. Novel method for the high-throughput processing of slides for the comet assay

    PubMed Central

    Karbaschi, Mahsa; Cooke, Marcus S.

    2014-01-01

    Single cell gel electrophoresis (the comet assay), continues to gain popularity as a means of assessing DNA damage. However, the assay's low sample throughput and laborious sample workup procedure are limiting factors to its application. “Scoring”, or individually determining DNA damage levels in 50 cells per treatment, is time-consuming, but with the advent of high-throughput scoring, the limitation is now the ability to process significant numbers of comet slides. We have developed a novel method by which multiple slides may be manipulated, and undergo electrophoresis, in batches of 25 rather than individually and, importantly, retains the use of standard microscope comet slides, which are the assay convention. This decreases assay time by 60%, and benefits from an electrophoresis tank with a substantially smaller footprint, and more uniform orientation of gels during electrophoresis. Our high-throughput variant of the comet assay greatly increases the number of samples analysed, decreases assay time, number of individual slide manipulations, reagent requirements and risk of damage to slides. The compact nature of the electrophoresis tank is of particular benefit to laboratories where bench space is at a premium. This novel approach is a significant advance on the current comet assay procedure. PMID:25425241

  1. Novel method for the high-throughput processing of slides for the comet assay.

    PubMed

    Karbaschi, Mahsa; Cooke, Marcus S

    2014-11-26

    Single cell gel electrophoresis (the comet assay), continues to gain popularity as a means of assessing DNA damage. However, the assay's low sample throughput and laborious sample workup procedure are limiting factors to its application. "Scoring", or individually determining DNA damage levels in 50 cells per treatment, is time-consuming, but with the advent of high-throughput scoring, the limitation is now the ability to process significant numbers of comet slides. We have developed a novel method by which multiple slides may be manipulated, and undergo electrophoresis, in batches of 25 rather than individually and, importantly, retains the use of standard microscope comet slides, which are the assay convention. This decreases assay time by 60%, and benefits from an electrophoresis tank with a substantially smaller footprint, and more uniform orientation of gels during electrophoresis. Our high-throughput variant of the comet assay greatly increases the number of samples analysed, decreases assay time, number of individual slide manipulations, reagent requirements and risk of damage to slides. The compact nature of the electrophoresis tank is of particular benefit to laboratories where bench space is at a premium. This novel approach is a significant advance on the current comet assay procedure.

  2. Rapid Methods for the Laboratory Identification of Pathogenic Microorganisms.

    DTIC Science & Technology

    1981-09-01

    Preliminary results provide strong evidence to show that the fungi, Candida and Cryptococcus , can be raoidly differentiated by a lectin test. SFor Oro...SUMMATION LECTIN-YEAST INTERACTIONS Objective: To find a lectin that selectively agglutinates Cryptococcus neoformans (the etiologic agent of...peanut), Conavalia ensiformis (Con A) and mango extract may potentially be utilized to differentiate Cryptococcus from the other yeasts most commonly

  3. Molecular diagnostics for human leptospirosis.

    PubMed

    Waggoner, Jesse J; Pinsky, Benjamin A

    2016-10-01

    The definitive diagnosis of leptospirosis, which results from infection with spirochetes of the genus Leptospira, currently relies on the use of culture, serological testing (microscopic agglutination testing), and molecular detection. The purpose of this review is to describe new molecular diagnostics for Leptospira and discuss advancements in the use of available methods. Efforts have been focused on improving the clinical sensitivity of Leptospira detection using molecular methods. In this review, we describe a reoptimized pathogenic species-specific real-time PCR (targeting lipL32) that has demonstrated improved sensitivity, findings by two groups that real-time reverse-transcription PCR assays targeting the 16S rrs gene can improve detection, and two new loop-mediated amplification techniques. Quantitation of leptospiremia, detection in different specimen types, and the complementary roles played by molecular detection and microscopic agglutination testing will be discussed. Finally, a protocol for Leptospira strain subtyping using variable number tandem repeat targets and high-resolution melting will be described. Molecular diagnostics have an established role for the diagnosis of leptospirosis and provide an actionable diagnosis in the acute setting. The use of real-time reverse-transcription PCR for testing serum/plasma and cerebrospinal fluid, when available, may improve the detection of Leptospira without decreasing clinical specificity.

  4. Evaluation of a rapid method for the detection of streptococcal group A antigen directly from throat swabs.

    PubMed Central

    Venezia, R A; Ryan, A; Alward, S; Kostun, W A

    1985-01-01

    Throat swabs from 196 pediatric patients were processed by a direct extraction-latex agglutination method (Group A Strep Direct Antigen Identification Test [DAI]) that detects group A streptococci in the specimen. The method requires a 45-min enzymatic extraction period at 37 degrees C and a 4-min reaction period with antibody-linked latex particles. The results were compared with those of the culture and fluorescent antibody methods and the clinical presentation of the patient for pharyngitis. Ninety-three percent of the specimens resulted in agreement by all tests, and 28% were culture positive for group A streptococci. Compared with the culture method, the DAI had a sensitivity and a specificity of 83% and 99%, respectively. The positive predictive values were 98% versus the culture method and 93% versus the fluorescent antibody method, whereas the negative predictive values were 94% versus both other methods. Of the 14 discrepant results when both clinical presentation of an acute pharyngitis and the test results were compared, the culture method provided the best correlation. An additional 64 specimens were processed by the DAI and another direct extraction-latex agglutination method (Culturette Ten-Minute Group A Strep ID Test), and the results were compared with those of the culture method. This group had a 40.6% culture isolation rate for group A streptococci. The sensitivity and specificity of the DAI and Strep ID methods versus the culture method were 81 and 100%, and 77 and 97%, respectively. These results indicate that the DAI is accurate for diagnosing group A streptococcal pharyngitis directly from throat swabs. However, negative results in the presence of a symptomatic patient must be confirmed by standard culture techniques. PMID:3884656

  5. Dinitrophenyl-reactive immunoglobulins in the serum of normal bowfin, Amia calva

    PubMed Central

    Bradshaw, Claire; Sigel, M. M.

    1972-01-01

    The sera from unimmunized bowfin agglutinate a large variety of red cells. Although they precipitate DNP-BSA they manifest only slight agglutinating capacity for DNP-coated cells. 15S immunoglobulin isolated by DEAE-cellulose chromatography followed by Sephadex G-200 gel filtration possessed a high level of broad reactivity towards unmodified DNP-coated cells, whereas the 7S immunoglobulin isolated by this procedure was inactive. However, following precipitation of whole serum with DNP-BSA both molecules could be recovered in a form which demonstrated specificity for DNP, in that both precipitated DNP-BSA and agglutinated DNP-coated cells but not unmodified cells. The mechanism of activation of the 7S molecule is not known but the data suggest that this immunoglobulin is divalent. ImagesFIG. 3FIG. 4 PMID:4624342

  6. Clinical utility of an automated instrument for gram staining single slides.

    PubMed

    Baron, Ellen Jo; Mix, Samantha; Moradi, Wais

    2010-06-01

    Gram stains of 87 different clinical samples were prepared by the laboratory's conventional methods (automated or manual) and by a new single-slide-type automated staining instrument, GG&B AGS-1000. Gram stains from either heat- or methanol-fixed slides stained with the new instrument were easy to interpret, and results were essentially the same as those from the methanol-fixed slides prepared as a part of the routine workflow. This instrument is well suited to a rapid-response laboratory where Gram stain requests are commonly received on a stat basis.

  7. A multiple-well method for immunohistochemical testing of many reagents on a single microscopic slide.

    PubMed

    McKeever, P E; Letica, L H; Shakui, P; Averill, D R

    1988-09-01

    Multiple wells (M-wells) have been made over tissue sections on single microscopic slides to simultaneously localize binding specificity of many antibodies. More than 20 individual 4-microliter wells over tissue have been applied/slide, representing more than a 5-fold improvement in wells/slide and a 25-fold reduction in reagent volume over previous methods. More than 30 wells/slide have been applied over cellular monolayers. To produce the improvement, previous strategies of placing specimens into wells were changed to instead create wells over the specimen. We took advantage of the hydrophobic properties of paint to surround the wells and to segregate the various different primary antibodies. Segregation was complete on wells alternating with and without primary monoclonal antibody. The procedure accommodates both frozen and paraffin sections, yielding slides which last more than a year. After monoclonal antibody detection, standard histologic stains can be applied as counterstains. M-wells are suitable for localizing binding of multiple reagents or sample unknowns (polyclonal or monoclonal antibodies, hybridoma supernatants, body fluids, lectins) to either tissues or cells. Their small sample volume and large number of sample wells/slide could be particularly useful for early screening of hybridoma supernatants and for titration curves in immunohistochemistry (McKeever PE, Shakui P, Letica LH, Averill DR: J Histochem Cytochem 36:931, 1988).

  8. Gravitational sliding of the Mt. Etna massif along a sloping basement

    NASA Astrophysics Data System (ADS)

    Murray, John B.; van Wyk de Vries, Benjamin; Pitty, Andy; Sargent, Phil; Wooller, Luke

    2018-04-01

    Geological field evidence and laboratory modelling indicate that volcanoes constructed on slopes slide downhill. If this happens on an active volcano, then the movement will distort deformation data and thus potentially compromise interpretation. Our recent GPS measurements demonstrate that the entire edifice of Mt. Etna is sliding to the ESE, the overall direction of slope of its complex, rough sedimentary basement. We report methods of discriminating the sliding vector from other deformation processes and of measuring its velocity, which averaged 14 mm year-1 during four intervals between 2001 and 2012. Though sliding of one sector of a volcano due to flank instability is widespread and well-known, this is the first time basement sliding of an entire active volcano has been directly observed. This is important because the geological record shows that such sliding volcanoes are prone to devastating sector collapse on the downslope side, and whole volcano migration should be taken into account when assessing future collapse hazard. It is also important in eruption forecasting, as the sliding vector needs to be allowed for when interpreting deformation events that take place above the sliding basement within the superstructure of the active volcano, as might occur with dyke intrusion or inflation/deflation episodes.

  9. A continuum treatment of sliding in Eulerian simulations of solid-solid and solid-fluid interfaces

    NASA Astrophysics Data System (ADS)

    Subramaniam, Akshay; Ghaisas, Niranjan; Lele, Sanjiva

    2017-11-01

    A novel treatment of sliding is developed for use in an Eulerian framework for simulating elastic-plastic deformations of solids coupled with fluids. In this method, embedded interfacial boundary conditions for perfect sliding are imposed by enforcing the interface normal to be a principal direction of the Cauchy stress and appropriate consistency conditions ensure correct transmission and reflection of waves at the interface. This sliding treatment may be used either to simulate a solid-solid sliding interface or to incorporate an internal slip boundary condition at a solid-fluid interface. Sliding laws like the Coulomb friction law can also be incorporated with relative ease into this framework. Simulations of sliding interfaces are conducted using a 10th order compact finite difference scheme and a Localized Artificial Diffusivity (LAD) scheme for shock and interface capturing. 1D and 2D simulations are used to assess the accuracy of the sliding treatment. The Richmyer-Meshkov instability between copper and aluminum is simulated with this sliding treatment as a demonstration test case. Support for this work was provided through Grant B612155 from the Lawrence Livermore National Laboratory, US Department of Energy.

  10. Kinetic of antigent-antibody reactions with scattering method

    NASA Astrophysics Data System (ADS)

    Bilyi, Olexander I.; Kiselyov, Yevgen M.; Novikov, Volodymyr P.

    2001-07-01

    The immune reactions of interaction antigen-antibody represent specific effect of an antigene with an antibody, which outcome are the complex immune aggregates forming precipitate in case of a soluble antigene, or agglutinate in case of a corpuscular antigene. Immunological methods which uses in the quality of carrier protein latex's polymeric microspheresis, gained name and method latex agglutination. Polymeric microspheresis have the array of advantages before biological carries, which consist in the opportunity of the variation of attributes surface and size microspheresis in the broad band of meanings with the preservation of narrow distribution particles behind measurements, the putting of functional groups, necessary for bunch with ligand on stage their synthesis, in ragidity at storage. The quantitative evaluation of parameters of a response of interaction antigen-antibody in immunology is possible by optical methods on a measurement of a modification of intensity of a light stream of a solution in an outcome of a course of a reaction. Concentration of immune complexes determine both on slacking a taking place stream of light, and on a modification of intensity of a stream of light scattering suspended particles in a solution. The process light scattering by colloidal aggregates are formed from suspension microspheresis with adsorbed on their surface protein is described. In report the physics principle of registration immune reaction by light scattering methods is concerned. The results of the effectiveness latex's preparation created on basis of the polymeric carries is described.

  11. A comparative study to evaluate the effects of ligation methods on friction in sliding mechanics using 0.022" slot brackets in dry state: An In-vitro study

    PubMed Central

    Vinay, K; Venkatesh, M J; Nayak, Rabindra S; Pasha, Azam; Rajesh, M; Kumar, Pradeep

    2014-01-01

    Background: Friction between archwires and brackets is assuming greater importance for finishing with increased use of sliding mechanics in orthodontics as friction impedes the desired tooth movement. The following study is conducted to compare and evaluate the effect of ligation on friction in sliding mechanics using 0.022" slot bracket in dry condition. Materials & Methods: In the study 48 combinations of brackets, archwires and different ligation techniques were tested in order to provide best combination that offers less friction during sliding mechanics. Instron- 4467 machine was used to evaluate static and kinetic friction force values and the results were subjected to Statistical Analysis and Anova test. Results: The results of the study showed that 0.022" metal brackets, Stainless steel wires and Slick modules provided the optimum frictional resistance to sliding mechanics. It is observed that frictional forces of 0.019" x 0.025" were higher when compared with 0.016" x 0.022" Stainless steel archwire due to the increase in dimension. Self-ligating brackets offered least friction followed by mini twin, variable force, regular stainless steel, ceramic with metal insert bracket and ceramic brackets. The stainless steel ligature offered less resistance than slick and grey modules, and TMA wires recorded maximum friction. Conclusion: The stainless steel archwire of 0.019" x 0.025" dimension are preferred during sliding mechanics, these archwires with variable force brackets ligated with Slick Modules offer decreased friction and is cost effective combination which can be utilized during sliding mechanics. How to cite the article: Vinay K, Venkatesh MJ, Nayak RS, Pasha A, Rajesh M, Kumar P. A comparative study to evaluate the effects of ligation methods on friction in sliding mechanics using 0.022" slot brackets in dry state: An In-vitro study. J Int Oral Health 2014;6(2):76-83. PMID:24876706

  12. Studies of the antibody nature of the rheumatoid factor

    PubMed Central

    Aho, K.; Harboe, M.; Leikola, J.

    1964-01-01

    The reaction of the rheumatoid factor (RF) with 7S γ-globulin antibodies of nine persons immunized with sheep erythrocytes was studied. All of a panel of rheumatoid sera with high Waaler-Rose titres agglutinated sheep cells sensitized with the human anti-sheep cell antibodies and O Rh positive cells sensitized with the `diagnostic' anti-CD serum Ripley. The RF measurable with these systems could be absorbed to diphtheria toxoid—human antitoxin precipitate, whereas the absorption with egg albumin—rabbit anti-egg albumin precipitate did not result in any appreciable titre reduction. However, the eluate from the rabbit precipitate was highly active in these systems, whereas Rh positive cells sensitized with anti-Rh sera suitable for Gm(a) typing were not regularly agglutinated. A markedly greater concentration of native than of heat-aggregated γ-globulin was needed for inhibition of the agglutination by the RF of cells heavily sensitized with the human anti-sheep cell antibodies. No appreciable difference in this respect was seen when using lightly sensitized cells. Only the heavily sensitized cells fixed complement. The `natural' 7S γ-globulin antibodies against sheep cells were neither suited for demonstration of RF nor did they fix complement. Sheep cells coated with 7S γ-globulin antibodies of a Gm(a+) person were agglutinated by a non-rheumatoid anti-Gm(a) serum, and this system was well suited for Gm(a) typing, whereas cells coated with antibodies of a Gm(a-) person were not agglutinated. Rheumatoid anti-Gm(a) sera agglutinated cells sensitized with antibodies of both Gm(a+) and Gm(a-) persons. Using cells coated with Gm(a+) antibodies, some distinction between Gm(a+) and Gm(a-) sera could be obtained under carefully controlled conditions. The use of a Gm(a-) coat resulted in a slight difference in the inhibiting capacity, which had no relation to the serum's Gm(a) type. The results suggest that the reaction of the RF with sheep cells heavily sensitized with human anti-sheep cell antibodies is essentially an interaction of the RF with immune aggregated γ-globulin, whereas when using lightly sensitized cells the individual γ-globulin molecules play a prominent role. PMID:14193154

  13. Outbreak of uncommon O4 non-agglutinating Salmonella typhimurium linked to minced pork, Saxony-Anhalt, Germany, January to April 2013.

    PubMed

    Alt, Katja; Simon, Sandra; Helmeke, Carina; Kohlstock, Claudia; Prager, Rita; Tietze, Erhard; Rabsch, Wolfgang; Karagiannis, Ioannis; Werber, Dirk; Frank, Christina; Fruth, Angelika

    2015-01-01

    In January 2013, the National Reference Centre for Salmonella (NRC) detected a salmonellosis cluster in Saxony-Anhalt, Germany, caused by uncommon O4 non-agglutinating, monophasic Salmonella (S.) Typhimurium DT193. Circulating predominant monophasic S. Typhimurium DT193 clones typically display resistance phenotype ASSuT. We investigated common exposures to control the outbreak, and conducted microbiological investigations to assess the strains' phenotype. We conducted a case-control study defining cases as persons living or working in Saxony-Anhalt diagnosed with the O4 non-agglutinating strain between January and March 2013. We selected two controls contemporarily reported with norovirus infection, frequency-matched on residence and age group, per case. We interviewed regarding food consumption, especially pork and its place of purchase. We calculated odds ratios (ORs) with 95% confidence intervals (95% CI) using logistic regression. The NRC investigated human and food isolates by PCR, SDS-PAGE, MLST, PFGE, MLVA and susceptibility testing. Altogether, 68 O4 non-agglutinating human isolates were confirmed between January and April 2013. Of those, 61 were assigned to the outbreak (median age 57 years, 44% female); 83% cases ≥ 60 years were hospitalized. Eating raw minced pork from butcheries within 3 days was associated with disease (31 cases, 28 controls; OR adjusted for sex: 3.6; 95% CI: 1.0-13). Phage type DT193 and MLST ST34 were assigned, and isolates' lipopolysaccharide (LPS) matched control strains. Isolates linked to Saxony-Anhalt exhibited PFGE type 5. ASSuT- and ACSSuT phenotype proportions were 34 and 39% respectively; 54% were resistant to chloramphenicol. Three pork isolates matched the outbreak strain. Raw minced pork was the most likely infection vehicle in this first reported outbreak caused by O4 non-agglutinating, mostly chloramphenicol-resistant S. Typhimurium DT193. High hospitalization proportions demand awareness on the risk of consumption of raw pork among elderly. LPS analysis indicated O4 expression; therefore, testing with antisera from different lots is recommendable in unexpected agglutination reactions.

  14. Color accuracy and reproducibility in whole slide imaging scanners

    PubMed Central

    Shrestha, Prarthana; Hulsken, Bas

    2014-01-01

    Abstract We propose a workflow for color reproduction in whole slide imaging (WSI) scanners, such that the colors in the scanned images match to the actual slide color and the inter-scanner variation is minimum. We describe a new method of preparation and verification of the color phantom slide, consisting of a standard IT8-target transmissive film, which is used in color calibrating and profiling the WSI scanner. We explore several International Color Consortium (ICC) compliant techniques in color calibration/profiling and rendering intents for translating the scanner specific colors to the standard display (sRGB) color space. Based on the quality of the color reproduction in histopathology slides, we propose the matrix-based calibration/profiling and absolute colorimetric rendering approach. The main advantage of the proposed workflow is that it is compliant to the ICC standard, applicable to color management systems in different platforms, and involves no external color measurement devices. We quantify color difference using the CIE-DeltaE2000 metric, where DeltaE values below 1 are considered imperceptible. Our evaluation on 14 phantom slides, manufactured according to the proposed method, shows an average inter-slide color difference below 1 DeltaE. The proposed workflow is implemented and evaluated in 35 WSI scanners developed at Philips, called the Ultra Fast Scanners (UFS). The color accuracy, measured as DeltaE between the scanner reproduced colors and the reference colorimetric values of the phantom patches, is improved on average to 3.5 DeltaE in calibrated scanners from 10 DeltaE in uncalibrated scanners. The average inter-scanner color difference is found to be 1.2 DeltaE. The improvement in color performance upon using the proposed method is apparent with the visual color quality of the tissue scans. PMID:26158041

  15. Plan averaging for multicriteria navigation of sliding window IMRT and VMAT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Craft, David, E-mail: dcraft@partners.org; Papp, Dávid; Unkelbach, Jan

    2014-02-15

    Purpose: To describe a method for combining sliding window plans [intensity modulated radiation therapy (IMRT) or volumetric modulated arc therapy (VMAT)] for use in treatment plan averaging, which is needed for Pareto surface navigation based multicriteria treatment planning. Methods: The authors show that by taking an appropriately defined average of leaf trajectories of sliding window plans, the authors obtain a sliding window plan whose fluence map is the exact average of the fluence maps corresponding to the initial plans. In the case of static-beam IMRT, this also implies that the dose distribution of the averaged plan is the exact dosimetricmore » average of the initial plans. In VMAT delivery, the dose distribution of the averaged plan is a close approximation of the dosimetric average of the initial plans. Results: The authors demonstrate the method on three Pareto optimal VMAT plans created for a demanding paraspinal case, where the tumor surrounds the spinal cord. The results show that the leaf averaged plans yield dose distributions that approximate the dosimetric averages of the precomputed Pareto optimal plans well. Conclusions: The proposed method enables the navigation of deliverable Pareto optimal plans directly, i.e., interactive multicriteria exploration of deliverable sliding window IMRT and VMAT plans, eliminating the need for a sequencing step after navigation and hence the dose degradation that is caused by such a sequencing step.« less

  16. Invasive Haemophilus influenzae disease in the vaccine era in Rio de Janeiro, Brazil

    PubMed Central

    Tuyama, Mari; Corrêa-Antônio, Jessica; Schlackman, Jessica; Marsh, Jane W; Rebelo, Maria C; Cerqueira, Elaine O; Nehab, Márcio; Kegele, Fabíola; Carmo, Getúlio F; Thielmann, Dominique CA; Barroso, Paulo F; Harrison, Lee H; Barroso, David E

    2017-01-01

    BACKGROUND Haemophilus influenzae (Hi) serotype b (Hib) conjugate vaccine was incorporated into the infant immunisation schedule in Brazil in 1999, where Hib was one of the major etiologic sources of community-acquired bacterial meningitis. OBJECTIVES The purpose of this study is to describe the molecular epidemiology of invasive Hi disease in Rio de Janeiro state, Brazil, before and after vaccine introduction. METHODS Surveillance data from 1986 to 2014 were analysed. Hi isolates recovered from cerebrospinal fluid (CSF) or blood from 1993 to 2014 were serotyped by slide agglutination, genotyped by multilocus sequence typing (MLST), and the capsule type evaluation, differentiation of serologically non-typeable isolates, and characterisation of the capsule (cap) locus was done by polymerase chain reaction. Antimicrobial susceptibility testing was performed using E-test. FINDINGS From 1986 to 1999 and from 2000 to 2014, 2580 and 197 (42% without serotype information) confirmed cases were reported, respectively. The case fatality rate was 17% and did not correlate with the strain. Hib and b- variant isolates belonged to ST-6, whereas serotype a isolates belonged to the ST-23 clonal complex. Serotype a appeared to emerge during the 2000s. Non-encapsulated isolates were non-clonal and distinct from the encapsulated isolates. Ampicillin-resistant isolates were either of serotype b or were non-encapsulated, and all of them were β-lactamase-positive but amoxicillin-clavulanic acid susceptible. MAIN CONCLUSIONS Although Hi meningitis became a relatively rare disease in Rio de Janeiro after the introduction of the Hib conjugate vaccine, the isolates recovered from patients have become more diverse. These results indicate the need to implement an enhanced surveillance system to continue monitoring the impact of the Hib conjugate vaccine. PMID:28225904

  17. Prevalence and characterization of multi-drug resistant Salmonella Enterica serovar Gallinarum biovar Pullorum and Gallinarum from chicken

    PubMed Central

    Parvej, Md. Shafiullah; Nazir, K. H. M. Nazmul Hussain; Rahman, M. Bahanur; Jahan, Mueena; Khan, Mohammad Ferdousur Rahman; Rahman, Marzia

    2016-01-01

    Aim: Salmonella is an important zoonotic pathogen responsible for animal and human diseases. The aim of the present study was to determine the prevalence and stereotyping of Salmonella isolates isolated from apparently healthy poultry. Furthermore, the clonal relatedness among the isolated Salmonella serovars was assessed. Materials and Methods: A total of 150 cloacal swab samples from apparently healthy chickens were collected, and were subjected for the isolation and identification of associated Salmonella organisms. The isolated colonies were identified and characterized on the basis of morphology, cultural characters, biochemical tests, slide agglutination test, polymerase chain reaction, and pulsed-field gel electrophoresis (PFGE). Antibiotic sensitivity patterns were also investigated using commonly used antibiotics. Results: Of the 150 samples, 11 (7.33%) produced characteristics pink colony with black center on XLD agar medium, and all were culturally and biochemically confirmed to be Salmonella. All possessed serovar-specific gene SpeF and reacted uniformly with group D antisera, suggesting that all of the isolates were Salmonella Enterica serovar Gallinarum, biovar Pullorum and/or Gallinarum. Antimicrobial susceptibility testing revealed that 54.54% of the isolated Salmonella Enterica serovars were highly sensitive to ciprofloxacin, whereas the 81.81% isolates were resistant to amoxycillin, doxycycline, kanamycin, gentamycin, and tetracycline. Pulsed-field gel electrophoresis of the XbaI-digested genomic DNA exhibited identical banding patterns, suggesting that the multidrug resistant Salmonella Enterica serovars occurring in commercial layers are highly clonal in Bangladesh. Conclusion: The present study was conducted to find out the prevalence of poultry Salmonella in layer chicken and to find out the clonal relationship among them. The data in this study suggest the prevalence of Salmonella Enterica, which is multidrug resistant and highly clonal for commercial layers of Bangladesh. PMID:27051187

  18. Automated single-slide staining system

    NASA Technical Reports Server (NTRS)

    Mills, S. M.; Wilkins, J. R.

    1974-01-01

    Apparatus developed to Gram-stain single slides automatically is flexible enough to accommodate other types of staining procedures. Method frees operator and eliminates necessity for subjective evaluations as to length of staining or decolorizing time.

  19. Evaluation of a rapid agglutination method for detection of equine red cell surface antigens (Ca and Aa) as part of pretransfusion testing.

    PubMed

    Owens, Sean D; Snipes, Joy; Magdesian, K Gary; Christopher, Mary M

    2008-03-01

    Blood typing before transfusion minimizes the risk of transfusion reactions and prevents immunization of the recipient against incompatible RBC antigens. The major RBC antigens that warrant identification before packed RBC or whole blood transfusions in horses are Ca and Aa. Standard blood-typing protocols are time-consuming (2.5-3.0 hours) and impractical in emergency settings. The purpose of this study was to determine whether equine RBCs could be typed for Ca and Aa antigens using sera from horses with RBC antibodies in a modified rapid (15 minute) blood-typing protocol. Serum was obtained from a horse with anti-Ca antibodies and from another horse with anti-Aa antibodies. The presence of agglutinating antibodies was confirmed with antibody screening. Venous blood samples, collected in citrate-phosphate-dextrose, were obtained from 21 horses of various breeds. Samples were blood typed in the Veterinary Medical Teaching Hospital Hematology Laboratory using standard methodology. Washed RBCs from each of the 21 horses were incubated individually with anti-Ca and anti-Aa sera at dilutions of 1:4, 1:8, and 1:16 for 15 and 30 minutes at room temperature and 37 degrees C. Of the 21 horses, 13 were identified as Aa+/Ca+, four were Aa+/Ca-, two were Aa-/Ca+, and two were Aa-/Ca-. All 17 Aa-positive horses had a positive agglutination reaction at all dilutions of anti-Aa serum, incubation times, and temperatures, while all Aa-negative horses were negative. Each Ca-positive horse had a positive agglutination reaction at all incubation time points and temperatures up to the 1:16 dilution of the anti-Ca serum. All Ca-negative horses were negative at all times, temperatures, and dilutions of anti-Ca serum. Use of the modified protocol on 26 hospitalized horses resulted in accurate typing, based on complete antibody screens. These results support the hypothesis that equine RBCs can be blood typed using a rapid (15 minute) protocol, at room temperature, for the presence of Ca and Aa antigens using equine-derived antisera. This technique may be beneficial for pretransfusion testing of equine patients in an emergency setting.

  20. Inference of Antibiotic Resistance and Virulence Among Diverse Group A Streptococcus Strains Using emm Sequencing and Multilocus Genotyping Methods

    DTIC Science & Technology

    2009-09-04

    apparent GAS-associated conditions were sampled by oropharyn- geal swab. Swabs were streaked on blood agar plates using Table 3. Isolate properties by...testing, samples were re-streaked on blood agar plates (5% sheep blood in TSA base) (Hardy Diagnostics, Santa Maria, CA), and incubated at 35–37uC with 5–10...sensitivity (A-disk method, Hardy Diagnostics) and positive GAS latex agglutination reaction (Hardy Diagnostics). Confirmed GAS isolates were then

  1. [The mechanism of change in speed of agglutination of human erythrocytes under the influence of adrenaline].

    PubMed

    Volodchenko, A I; Tsirkin, V I; Kostiaev, A A

    2014-01-01

    In the study of red blood cells of 80 men found that adrenaline (10(-10) - 10(-6) g/mL) and phenylephrine (10-(10) - 10(-6) g/mL) dose-dependently increase the speed of agglutination of red blood cells, according to the decrease in agglutination of the start time and ginipral (10(-10) - 10(-7) g/mL), on the contrary, decreases it. The effect of adrenaline and phenylephrine is blocked by nicergoline (10(-6) g/mL), increased obzidan (10(-6) g/mL) and does not change under the action ofyohimbine (10(-6) g/mL) and atenolol (10(-6) g/mL). These data indicate that the speed of agglutination increases with activation alpha1-adrenergic receptor (AR) and decreases in the activation of beta2-AR, while the activation of alpha2- and beta1-AR does not affect it. Trifluoperazine (10(-6) g/mL) as the calmodulin antagonist, barium chloride (10(-6) g/mL) as a blocked of Ca(2+)-dependent K(+)-channels and indomethacine (10(-6) g/mL) as an inhibitor of cyclooxygenase and phospholipase A2 inhibit the ability of adrenaline to increases the speed of agglutination of red blood cells. This suggests that the effect of adrenaline caused an increase in erythrocyte entry of Ca2+, activation of calmodulin, cyclooxygenase, phospholipase A2 and the release of K+ from red blood cell through the Ca(2+)-dependent K+ channels, which is regarded as a manifestation of eryptosis. Indirectly, this means that more efficient activation of alpha1-AR and beta2-AR, respectively, increases or, conversely, decreases the rate of eryptosis.

  2. Assessing the chronology of bedrock landslides in the Oregon Coastal Range using visible near-infrared spectroscopy

    NASA Astrophysics Data System (ADS)

    Mathabane, N.; Cerovski-Darriau, C.; Sweeney, K. E.; Roering, J. J.

    2013-12-01

    Obtaining accurate chronological data for landslides is critical to understanding their causes as well as their dynamics. The ability to easily and inexpensively date various parts of a landslide can provide insight not only into the 'When' of landslides but also on the 'How' and 'Why' as well. In this study, we apply visible near-infrared (VisNIR) spectroscopy as a means to date landslide soils in a setting with uniform climate and bedrock lithology. In our Oregon Coast Range site, as sandstone-derived soils weather over time, pedogenic hematite accumulates and alters the color of the soil at a quantifiable and discernable rate. This rate having already been established through a soil chronosequence study, we can use the redness of a soil as a proxy for soil age. This is a potentially economical dating method as it does not rely on expensive radioisotopes and requires only a small amount of sample to process. We collected 39 B-horizon soil samples from 7 different slides and used VisNIR spectroscopy to identify the soil residence time of the landslides. The majority of the samples possessed ages between 75,000 and 150,000 years of age, though several slides registered ages over 200,000 years. The average percent error associated with the landslide ages was ~30-35%, although this value was lower for younger slides (<100,000 years) and greater for slides (>200,000 years). Younger slides were more homogenous in age while older slides exhibited more variability. Additionally, there was lower variability in auger-collected samples when compared to samples collected from road-cuts. Our results suggest that VisNIR spectroscopy may prove a more useful dating method on younger, less disturbed landslides but fail to truly capture the age of older, more complicated slides due to its reliance on a specific pedogentic model for hematite weathering as well as the increased risk for complex slide history. This method could be useful in a regional characterization of landslide chronology for similar biomes and provide scientists with a currently lacking catalogue of ancient landslide ages. Such a catalogue could provide significant insight into the mechanisms and potential triggers of bedrock landslides. Landslide ages and geospatial distribution of the four largest slides sampled in the course of this study. There was significant local variability in slide ages, especially in older, redder slides like Vaughn and Wolf Creek.

  3. Diagnosis and treatment of Neospora caninum--associated dermatitis in a red fox (Vulpes vulpes) with concurrent Toxoplasma gondii infection.

    PubMed

    Duhey, Jitender P; Whitesell, Leah E; Culp, William E; Daye, Sharon

    2014-06-01

    A 3-mo-old red fox (Vulpes vulpes) developed generalized crusty plaques on its body during rehabilitation after an automobile accident requiring amputation of one leg. Histologic examination of skin lesion biopsy revealed granulomatous dermatitits with many intralesional protozoal tachyzoites. The protozoa stained positively with antibodies to Neospora caninum but not to Toxoplasma gondii. Treatment with clindamycin hydrochloride (10 mg/kg, twice daily, s.c.) for 1 mo completely resolved lesions, and protozoa were not demonstrable in biopsy of skin after treatment. The fox had agglutinating antibodies to T. gondii (modified agglutination test, titer 1:3200) and N. caninum (Neospora agglutination test, titer 1:25), and viable T. gondii (genotype III) was isolated from the skin biopsy after treatment. This is the first report of clinical neosporosis in a wild canid.

  4. STUDIES ON THE BIOLOGY OF STREPTOCOCCUS

    PubMed Central

    Stevens, Franklin A.; Dochez, A. R.

    1924-01-01

    1. Strains of hemolytic streptococci from cases of scarlet fever occurring in New York, San Francisco, Chicago, Baltimore, and Copenhagen, Denmark, all interagglutinate with immune sera prepared with these strains. 2. Sera prepared with these strains do not agglutinate pyogenic streptococci or strains isolated from cases of septic sore throat. 3. The strains obtained from the throats of patients from an epidemic of scarlet fever and the strain from the milk responsible for this epidemic fall into the scarlatinal group according to these agglutination tests. 4. Absorption tests can be carried out with these strains and sera under proper conditions. 5. A group of hemolytic streptococci biologically distinct from streptococci from other sources than scarlet fever is constantly associated with scarlatina. They constitute a group of closely related streptococci which may be identified by agglutination tests. PMID:19868913

  5. [Serodiagnosis of toxoplasmosis: a comparative multicenter study of a standard scale through various actual tests and expression of the results in international units. Groupe de travail toxoplasmose du Contrôle national de qualité en parasotologie. Syndicat des fabricants de réactifs de laboratoire. Groupe de travail standardisation des tests sérologiques du Réseau européen de lutte contre la toxoplasmose congénitale].

    PubMed

    Petithory, J C; Ambroise-Thomas, P; De Loye, J; Pelloux, H; Goullier-Fleuret, A; Milgram, M; Buffard, C; Garin, J P

    1996-01-01

    Reported are the results of a multicentre study involving 40 laboratories that was carried out in France to assess all the currently available methods used for the serodiagnosis of toxoplasmosis. For this purpose 10 batches of control sera were prepared with titres in the range 0-260 IU per ml. These sera were tested in nine laboratories using immunofluorescence methods; in three laboratories using dye tests; in forty laboratories using enzyme-linked immunosorbent assay; in four laboratories using direct agglutination and haemagglutination; in seven laboratories using the high-sensitivity IgG agglutination test; and in three laboratories using the latex agglutination test. In this way, 70 series of titrations were carried out using seven procedures and the results were compared with those obtained using the WHO reference serum in 15 cases, with the French national E6 serum in 16 other cases, and in 39 cases using 15 reference sera supplied by the reagent manufacturers. Rigorous comparison of the tests was not possible in all cases because one aim of the study was to ensure that the tests were carried out under the usual working conditions that prevailed in the participating laboratories. The results obtained indicate that the serological tests currently available for toxoplasmosis are acceptable for its serodiagnosis. Presentation of the titres in IU has advantages; however, caution is required since the definition of IU varies according to the test and reagents used. It is therefore essential that the conditions and limits for a positive reaction be carefully defined in each case, especially for commercially available kits.

  6. INRA, a new high-frequency antigen in the INDIAN (IN023) blood group system

    PubMed Central

    Joshi, Sanmukh R.; Sheladiya, Ankita; Mendapara-Dobariya, Kinjal V.

    2017-01-01

    BACKGROUND: The INDIAN blood group system comprises 4 antigens sensitive to enzymes and 2-aminoethyl isothiouronium bromide (AET). AIM: The patient's antibody was investigated for its specificity to the high-frequency antigens (HFA) of this system. MATERIAL AND METHODS: Low ionic strength solution (LISS)-tube/LISS-indirect antiglobulin test (IAT) methods were used. The patient's red blood cells (RBCs) were tested with antisera to HFA. Her antibody was tested with RBCs lacking the HFA. Furthermore, it was tested with RBCs as untreated or treated with enzyme or AET. The genetic sequence was studied for mutation in CD44 gene that encodes INDIAN antigens. RESULTS: The patient was grouped A1B, RhD+, antibody screening test positive, direct antiglobulin test negative. A negative autocontrol test had suggested to the alloantibody being present. Antibody had agglutinated RBCs in LISS-tube at RT and by LISS-IAT at 37°C. The RBCs of the 11-cell panel, those lacking HFA and from 50 random donors, were agglutinated by her antibody indicating its specificity to the HFA, though the RBCs of Lu (a-b-)/In (Lu) type showed a weaker reaction. The patient's RBCs were agglutinated by antisera to a number of the enzyme-sensitive HFA, including those of INDIAN blood groups. The antibody showed reduced reactivity with the RBCs treated with papain, chymotrypsin, and AET but resistant to trypsin and dithiothreitol. The patient's genetic sequence revealed a novel homozygous mutation 449G>A in exon 5 of CD44. CONCLUSION: The antibody to enzyme sensitive HFA was tested for serological and molecular genetics studies and found to be directed to the novel HFA, named as INRA of the INDIAN blood group system and was assigned a numerical symbol IN: 005 by the International Society of Blood Transfusion (ISBT). PMID:28970678

  7. Mechanical interlocking of cotton fibers on slightly textured surfaces of metallic cylinders

    PubMed Central

    Zhang, Youqiang; Tian, Yu; Meng, Yonggang

    2016-01-01

    Mechanical interlocking is widely applied in industry and general lives of human beings. In this work, we realized the control of locking or sliding states of cotton fibers on the metal surfaces with slightly different textures through traditional machining. Three types of sliding states, i.e., locking, one-way sliding, and two-way sliding have been achieved. It is found that the locking or sliding of the cotton fibers on the metallic cylinder depends on the friction coefficient and the ratio of cotton fiber diameter, 2r, to the height of the rough peaks, h, of metal surfaces. When the critical ratio h/r exceeds 1, the cotton fibers could tightly attach to the metallic surface through mechanical interlocking. This work provided a convenient and universal method for the control of interlocking or sliding of fiber-based materials on textured surfaces. PMID:27156720

  8. Clinical Utility of an Automated Instrument for Gram Staining Single Slides ▿

    PubMed Central

    Baron, Ellen Jo; Mix, Samantha; Moradi, Wais

    2010-01-01

    Gram stains of 87 different clinical samples were prepared by the laboratory's conventional methods (automated or manual) and by a new single-slide-type automated staining instrument, GG&B AGS-1000. Gram stains from either heat- or methanol-fixed slides stained with the new instrument were easy to interpret, and results were essentially the same as those from the methanol-fixed slides prepared as a part of the routine workflow. This instrument is well suited to a rapid-response laboratory where Gram stain requests are commonly received on a stat basis. PMID:20410348

  9. Short segment search method for phylogenetic analysis using nested sliding windows

    NASA Astrophysics Data System (ADS)

    Iskandar, A. A.; Bustamam, A.; Trimarsanto, H.

    2017-10-01

    To analyze phylogenetics in Bioinformatics, coding DNA sequences (CDS) segment is needed for maximal accuracy. However, analysis by CDS cost a lot of time and money, so a short representative segment by CDS, which is envelope protein segment or non-structural 3 (NS3) segment is necessary. After sliding window is implemented, a better short segment than envelope protein segment and NS3 is found. This paper will discuss a mathematical method to analyze sequences using nested sliding window to find a short segment which is representative for the whole genome. The result shows that our method can find a short segment which more representative about 6.57% in topological view to CDS segment than an Envelope segment or NS3 segment.

  10. Switching PD-based sliding mode control for hovering of a tilting-thruster underwater robot.

    PubMed

    Jin, Sangrok; Bak, Jeongae; Kim, Jongwon; Seo, TaeWon; Kim, Hwa Soo

    2018-01-01

    This paper presents a switching PD-based sliding mode control (PD-SMC) method for the 6-degree-of-freedom (DOF) hovering motion of the underwater robot with tilting thrusters. Four thrusters of robot can be tilted simultaneously in the horizontal and vertical directions, and the 6-DOF motion is achieved by switching between two thruster configurations. Therefore, the tilting speed of thruster becomes the most essential parameter to determine the stability of hovering motion. Even though the previous PD control ensures stable hovering motion within a certain ranges of tilting speed, a PD-SMC is suggested in this paper by combining PD control with sliding mode control in order to achieve acceptable hovering performance even at the much lower tilting speeds. Also, the sign function in the sliding mode control is replaced by a sigmoid function to reduce undesired chattering. Simulations show that while PD control is effective only for tilting duration of 600 ms, the PD-based sliding mode control can guarantee the stable hovering motion of underwater robot even for the tilting duration of up to 1500 ms. Extensive experimental results confirm the hovering performance of the proposed PD-SMC method is much superior to that of PD method for much larger tilting durations.

  11. Red blood cell membrane viscoelasticity, agglutination and zeta potential measurements with double optical tweezers

    NASA Astrophysics Data System (ADS)

    Fontes, Adriana; Fernandes, Heloise P.; Barjas-Castro, Maria L.; de Thomaz, André A.; de Ysasa Pozzo, Liliana; Barbosa, Luiz C.; Cesar, Carlos L.

    2006-02-01

    The red blood cell (RBC) viscoelastic membrane contains proteins and glycolproteins embedded in, or attached, to a fluid lipid bilayer and are negatively charged, which creates a repulsive electric (zeta) potential between the cells and prevents their aggregation in the blood stream. There are techniques, however, to decrease the zeta potential to allow cell agglutination which are the basis of most of the tests of antigen-antibody interactions in blood banks. This report shows the use of a double optical tweezers to measure RBC membrane viscosity, agglutination and zeta potential. In our technique one of the optical tweezers trap a silica bead that binds strongly to a RBC at the end of a RBCs rouleaux and, at the same time, acts as a pico-Newton force transducer, after calibration through its displacement from the equilibrium position. The other optical tweezers trap the RBC at the other end. To measure the membrane viscosity the optical force is measured as a function of the velocity between the RBCs. To measure the adhesion the tweezers are slowly displaced apart until the RBCs disagglutination happens. The RBC zeta potential is measured in two complimentary ways, by the force on the silica bead attached to a single RBC in response to an applied electric field, and the conventional way, by the measurement of terminal velocity of the RBC after released from the optical trap. These two measurements provide information about the RBC charges and, also, electrolytic solution properties. We believe this can improve the methods of diagnosis in blood banks.

  12. Validation of paper-based assay for rapid blood typing.

    PubMed

    Al-Tamimi, Mohammad; Shen, Wei; Zeineddine, Rania; Tran, Huy; Garnier, Gil

    2012-02-07

    We developed and validated a new paper-based assay for the detection of human blood type. Our method involves spotting a 3 μL blood sample on a paper surface where grouping antibodies have already been introduced. A thin film chromatograph tank was used to chromatographically elute the blood spot with 0.9% NaCl buffer for 10 min by capillary absorption. Agglutinated red blood cells (RBCs) were fixed on the paper substrate, resulting in a high optical density of the spot, with no visual trace in the buffer wicking path. Conversely, nonagglutinated RBCs could easily be eluted by the buffer and had low optical density of the spot and clearly visible trace of RBCs in the buffer wicking path. Different paper substrates had comparable ability to fix agglutinated blood, while a more porous substrate like Kleenex paper had enhanced ability to elute nonagglutinated blood. Using optimized conditions, a rapid assay for detection of blood groups was developed by spotting blood to antibodies absorbed to paper and eluted with 200 μL of 0.9% NaCl buffer directly by pipetting. RBCs fixation on paper accurately detected blood groups (ABO and RhD) using ascending buffer for 10 min or using a rapid elution step in 100/100 blood samples including 4 weak AB and 4 weak RhD samples. The assay has excellent reproducibility where the same blood group was obtained in 26 samples assessed in 2 different days. Agglutinated blood fixation on porous paper substrate provides a new, simple, and sensitive assay for rapid detection of blood group for point-of-care applications. © 2011 American Chemical Society

  13. Development and evaluation of a recombinant-glycoprotein-based latex agglutination test for rabies virus antibody assessment.

    PubMed

    Jemima, Ebenezer Angel; Manoharan, Seeralan; Kumanan, Kathaperumal

    2014-08-01

    The measurement of neutralizing antibodies induced by the glycoprotein of rabies virus is indispensable for assessing the level of neutralizing antibodies in animals or humans. A rapid fluorescent focus inhibition test (RFFIT) has been approved by WHO and is the most widely used method to measure the virus-neutralizing antibody content in serum, but a rapid test system would be of great value to screen large numbers of serum samples. To develop and evaluate a latex agglutination test (LAT) for measuring rabies virus antibodies, a recombinant glycoprotein was expressed in an insect cell system and purified, and the protein was coated onto latex beads at concentrations of 0.1, 0.25, 0.5, 0.75, and 1 mg/ml to find out the optimal concentration for coating latex beads. It was found that 0.5 mg/ml of recombinant protein was optimal for coating latex beads, and this concentration was used to sensitize the latex beads for screening of dog serum samples. Grading of LAT results was done with standard reference serum with known antibody titers. A total of 228 serum samples were tested, out of which 145 samples were positive by both RFFIT and LAT, and the specificity was found to be 100 %. In RFFIT, 151 samples were positive, the sensitivity was found to be 96.03 %, and the accuracy/concordance was found to be 97.39 %. A rapid field test-a latex agglutination test (LAT)-was developed and evaluated for rabies virus antibody assessment using recombinant glycoprotein of rabies virus expressed in an insect cell system.

  14. Prehospital Use of Plasma for Traumatic Hemorrhage

    DTIC Science & Technology

    2014-06-01

    known reagent B- cells o Mix o Spin in centrifuge for 15 seconds o Read for agglutination macroscopically o If agglutination is present, the unit...of days in the hospital, number of days on a ventilator, number of operations, number of infections, and cumulative utilization of blood products...procedure development and the items to be accomplished follow: GOALS:  Safe and adequate delivery, storage, and handover of plasma from Blood

  15. Unevenness of Sliding Surface of Overhead Rigid Conductor Lines and Method for Reducing Unevenness

    NASA Astrophysics Data System (ADS)

    Aboshi, Mitsuo; Shimizu, Masashi

    Rigid conductor lines are used in many subways, because the use of such conductor lines reduces the risk of accidents and because less space is required for their installation. However, as the unevenness of the sliding surface of the rigid conductor lines significantly influences the fluctuations in the contact force between pantographs and contact lines, it is necessary to decrease the unevenness at the construction as well as the maintenance stages. In order to investigate the installation accuracy of overhead rigid conductor lines, we have developed a device that accurately and continuously measures the unevenness of the sliding surface. By using this measuring device, we have confirmed that the unevenness of the sliding surface depends on various factors such as the sag between the support points, the deformation of the aluminum base or the conductive rail in the case of a long wavelength, the slight sagging unevenness between the bolts of the long ear, the undulating wear etc. This paper describes the actual unevenness conditions and the technical methods for decreasing the unevenness of the sliding surface of overhead rigid conductor lines.

  16. Sliding Mode Approaches for Robust Control, State Estimation, Secure Communication, and Fault Diagnosis in Nuclear Systems

    NASA Astrophysics Data System (ADS)

    Ablay, Gunyaz

    Using traditional control methods for controller design, parameter estimation and fault diagnosis may lead to poor results with nuclear systems in practice because of approximations and uncertainties in the system models used, possibly resulting in unexpected plant unavailability. This experience has led to an interest in development of robust control, estimation and fault diagnosis methods. One particularly robust approach is the sliding mode control methodology. Sliding mode approaches have been of great interest and importance in industry and engineering in the recent decades due to their potential for producing economic, safe and reliable designs. In order to utilize these advantages, sliding mode approaches are implemented for robust control, state estimation, secure communication and fault diagnosis in nuclear plant systems. In addition, a sliding mode output observer is developed for fault diagnosis in dynamical systems. To validate the effectiveness of the methodologies, several nuclear plant system models are considered for applications, including point reactor kinetics, xenon concentration dynamics, an uncertain pressurizer model, a U-tube steam generator model and a coupled nonlinear nuclear reactor model.

  17. The platelet count in EDTA-anticoagulated blood from patients with thrombocytopenia may be underestimated when measured in routine laboratories.

    PubMed

    Podda, Gian Marco; Pugliano, Mariateresa; Femia, Eti Alessandra; Mezzasoma, Anna Maria; Gresele, Paolo; Carpani, Giovanni; Cattaneo, Marco

    2012-07-01

    Spuriously low platelet counts (PCs) can be observed in normal blood samples anticoagulated with ethylenediamine tetra-acetic acid (EDTA)and, much less frequently, with citrate-tris-pyridossalphosphate (CPT),due to time-dependent in vitro platelet agglutination. Accuracy in PC determination is essential as PC is one of the parameters that usually guides treatment for thrombocytopenic patients. PCs of 93 thrombocy to penic patients were measured in EDTA- or CPT-anticoagulated blood samples immediately after sampling (t0) and 90 min (t90) after storage at room temperature. The presence of platelet agglutinates in blood samples was determined by examining blood smears using optical microscopy.PCs decreased at t90 with both anticoagulants. Platelet agglutinates were present at t90 in 27% of EDTA-samples vs. 2% of CPT-samples with decreased PCs (P < 0.001). Based on PCs in EDTA-samples, 15 patients (16%) shifted from a lower bleeding risk at t0 to a higher bleeding risk category at t90 (P 5 0.019), compared to 5 (5%) patients, based on PCs in CPT-samples. Therefore, time-dependent in vitro platelet agglutination in EDTA-blood samples may cause underestimation of PCs in thrombocytopenic patients, possibly leading to improper management.

  18. Glycomics-based analysis of chicken red blood cells provides insight into the selectivity of the viral agglutination assay.

    PubMed

    Aich, Udayanath; Beckley, Nia; Shriver, Zachary; Raman, Rahul; Viswanathan, Karthik; Hobbie, Sven; Sasisekharan, Ram

    2011-05-01

    Agglutination of red blood cells (RBCs), including chicken RBCs (cRBCs), has been used extensively to estimate viral titer, to screen glycan-receptor binding preference, and to assess the protective response of vaccines. Although this assay enjoys widespread use, some virus strains do not agglutinate RBCs. To address these underlying issues and to increase the usefulness of cRBCs as tools for studying viruses, such as influenza, we analyzed the cell surface N-glycans of cRBCs. On the basis of the results obtained from complementary analytical strategies, including MS, 1D and 2D-NMR spectroscopy, exoglycosidase digestions, and HPLC profiling, we report the major glycan structures present on cRBCs. By comparing the glycan structures of cBRCs with those of representative human upper respiratory cells, we offer a possible explanation for the fact that certain influenza strains do not agglutinate cRBCs, using specific human-adapted influenza hemagglutinins as examples. Finally, recent understanding of the role of various glycan structures in high affinity binding to influenza hemagglutinins provides context to our findings. These results illustrate that the field of glycomics can provide important information with respect to the experimental systems used to characterize, detect and study viruses. © 2011 The Authors Journal compilation © 2011 FEBS.

  19. Automated point-of-care testing for ABO agglutination test: proof of concept and validation.

    PubMed

    El Kenz, H; Corazza, F

    2015-07-01

    ABO-incompatible red blood cell transfusions still represent an important hazard in transfusion medicine. Therefore, some countries have introduced a systematic bedside ABO agglutination test checking that the right blood is given to the right patient. However, this strategy requires an extremely time-consuming learning programme and relies on a subjective interpretation of ABO test cards agglutination. We developed a prototype of a fully automated device performing the bedside agglutination test that could be completed by reading of a barcoded wristband. This POCT checks the ABO compatibility between the patient and the blood bag. Proof of concept and analytical validation of the prototype has been completed on 451 blood samples: 238 donor packed red blood cells, 137 consecutive unselected patients for whom a blood group determination had been ordered and on 76 patient samples selected with pathology that could possibly interfere with or impair performances of the assay. We observed 100% concordance for ABO blood groups between the POCT and the laboratory instrument. These preliminary results demonstrate the feasibility of ABO determination with a simple POCT device eliminating manipulation and subjective interpretation responsible for transfusion errors. This device should be linked to the blood bank system allowing all cross-check of the results. © 2015 International Society of Blood Transfusion.

  20. [Evaluation of Prolex for the rapid identification of streptococci isolated in medical microbiology].

    PubMed

    Loubinoux, J; Mihaila-Amrouche, L; Bouvet, A

    2004-10-01

    The need to rapidly identify streptococci responsible for acute infectious diseases has led to the development of agglutination techniques that are able to identify streptococcal group antigens (A, B, C, D, F, and G) directly from primoculture colonies on blood agar. The Prolex agglutination tests (Pro-Lab Diagnostics, Richmond Hill, Ontario, Canada), distributed in France by i2a, have been used for the determination of group antigens of 166 isolates of streptococci and enterococci previously identified in the National Reference Center for Streptococci. The results obtained with the Prolex reagents have permitted to correctly identify all pyogenic beta-hemolytic streptococci (23 Streptococcus pyogenes, 21 Streptococcus agalactiae, 33 Streptococcus dysgalactiae subsp. equisimilis including 6 group C and 27 group G, and 5 Streptococcus porcinus including 4 group B). Four differences between unexpected agglutinations (A or F) and species identifications have been obtained. These differences were observed for four non-hemolytic isolates of Streptococcus mutans, Streptococcus gordonii, Streptococcus infantarius, and Streptococcus suis. The anti-D reagent has been of value as a marker for isolates of enterococci. Thus, these results confirm the abilities of these agglutination tests for the grouping of beta-hemolytic streptococci. Moreover, the use of Prolex has the advantage to be rapid because of the non-enzymatic but chemical extraction of streptococcal antigens.

  1. The contribution of MIB 1 in the accurate grading of vulvar intraepithelial neoplasia.

    PubMed Central

    van Beurden, M; de Craen, A J; de Vet, H C; Blaauwgeers, J L; Drillenburg, P; Gallee, M P; de Kraker, N W; Lammes, F B; ten Kate, F J

    1999-01-01

    AIM: To determine the interobserver variation in scoring presence and grade of vulvar intraepithelial neoplasia (VIN) in haematoxylin/eosin (H/E) slides, MIB 1 slides, and the combined use of H/E and MIB 1 slides. METHODS: 10 slides were stained with H/E and MIB 1 with each of the following diagnoses: normal vulvar skin, VIN 1, VIN 2, and VIN 3. Six observers first scored the H/E slides separately from the MIB 1 slides and second the combined H/E and MIB 1 slides. RESULTS: Unweighted group kappa for MIB 1 was 0.62 and the weighted group kappa was 0.91. This was significantly better than the unweighted group kappa for H/E slides (0.47, p = 0.023) as well as the weighted group kappa for H/E slides (0.82, p = 0.014). There was no improvement by the combined use of H/E and MIB 1 slides. VIN 2 is far less confused with VIN 3 in the combined use of H/E and MIB 1 slides (9%) than in H/E slides (38%) (p = 0.007). There is a tendency to grade VIN in a two tailed grading system rather than a three tailed grading system, which became more apparent with the combined use of H/E and MIB 1 slides. CONCLUSIONS: The interobserver variation with sole use of MIB 1 is better than with the use of H/E stain in VIN. The use of MIB 1 in grading VIN diminishes confusion between VIN 2 and VIN 3 fourfold. A two tailed grading system for VIN seems already to work in daily practice. Images PMID:10690171

  2. Microscopic validation of whole mouse micro-metastatic tumor imaging agents using cryo-imaging and sliding organ image registration.

    PubMed

    Liu, Yiqiao; Zhou, Bo; Qutaish, Mohammed; Wilson, David L

    2016-01-01

    We created a metastasis imaging, analysis platform consisting of software and multi-spectral cryo-imaging system suitable for evaluating emerging imaging agents targeting micro-metastatic tumor. We analyzed CREKA-Gd in MRI, followed by cryo-imaging which repeatedly sectioned and tiled microscope images of the tissue block face, providing anatomical bright field and molecular fluorescence, enabling 3D microscopic imaging of the entire mouse with single metastatic cell sensitivity. To register MRI volumes to the cryo bright field reference, we used our standard mutual information, non-rigid registration which proceeded: preprocess → affine → B-spline non-rigid 3D registration. In this report, we created two modified approaches: mask where we registered locally over a smaller rectangular solid, and sliding organ . Briefly, in sliding organ , we segmented the organ, registered the organ and body volumes separately and combined results. Though s liding organ required manual annotation, it provided the best result as a standard to measure other registration methods. Regularization parameters for standard and mask methods were optimized in a grid search. Evaluations consisted of DICE, and visual scoring of a checkerboard display. Standard had accuracy of 2 voxels in all regions except near the kidney, where there were 5 voxels sliding. After mask and sliding organ correction, kidneys sliding were within 2 voxels, and Dice overlap increased 4%-10% in mask compared to standard . Mask generated comparable results with sliding organ and allowed a semi-automatic process.

  3. Assessing the composition of fragmented agglutinated foraminiferal assemblages in ancient sediments: comparison of counting and area-based methods in Famennian samples (Late Devonian)

    NASA Astrophysics Data System (ADS)

    Girard, Catherine; Dufour, Anne-Béatrice; Charruault, Anne-Lise; Renaud, Sabrina

    2018-01-01

    Benthic foraminifera have been used as proxies for various paleoenvironmental variables such as food availability, carbon flux from surface waters, microhabitats, and indirectly water depth. Estimating assemblage composition based on morphotypes, as opposed to genus- or species-level identification, potentially loses important ecological information but opens the way to the study of ancient time periods. However, the ability to accurately constrain benthic foraminiferal assemblages has been questioned when the most abundant foraminifera are fragile agglutinated forms, particularly prone to fragmentation. Here we test an alternate method for accurately estimating the composition of fragmented assemblages. The cumulated area per morphotype method is assessed, i.e., the sum of the area of all tests or fragments of a given morphotype in a sample. The percentage of each morphotype is calculated as a portion of the total cumulated area. Percentages of different morphotypes based on counting and cumulated area methods are compared one by one and analyzed using principal component analyses, a co-inertia analysis, and Shannon diversity indices. Morphotype percentages are further compared to an estimate of water depth based on microfacies description. Percentages of the morphotypes are not related to water depth. In all cases, counting and cumulated area methods deliver highly similar results, suggesting that the less time-consuming traditional counting method may provide robust estimates of assemblages. The size of each morphotype may deliver paleobiological information, for instance regarding biomass, but should be considered carefully due to the pervasive issue of fragmentation.

  4. Uncertainty Quantification for Robust Control of Wind Turbines using Sliding Mode Observer

    NASA Astrophysics Data System (ADS)

    Schulte, Horst

    2016-09-01

    A new quantification method of uncertain models for robust wind turbine control using sliding-mode techniques is presented with the objective to improve active load mitigation. This approach is based on the so-called equivalent output injection signal, which corresponds to the average behavior of the discontinuous switching term, establishing and maintaining a motion on a so-called sliding surface. The injection signal is directly evaluated to obtain estimates of the uncertainty bounds of external disturbances and parameter uncertainties. The applicability of the proposed method is illustrated by the quantification of a four degree-of-freedom model of the NREL 5MW reference turbine containing uncertainties.

  5. QUALITY ASSESSMENT OF CONFOCAL MICROSCOPY SLIDE-BASED SYSTEMS: INSTABLITY

    EPA Science Inventory

    Background: All slide-based fluorescence cytometry detections systems basically include an excitation light source, intermediate optics, and a detection device (CCD or PMT). Occasionally, this equipment becomes unstable, generating unreliable and inferior data. Methods: A num...

  6. Composite fuzzy sliding mode control of nonlinear singularly perturbed systems.

    PubMed

    Nagarale, Ravindrakumar M; Patre, B M

    2014-05-01

    This paper deals with the robust asymptotic stabilization for a class of nonlinear singularly perturbed systems using the fuzzy sliding mode control technique. In the proposed approach the original system is decomposed into two subsystems as slow and fast models by the singularly perturbed method. The composite fuzzy sliding mode controller is designed for stabilizing the full order system by combining separately designed slow and fast fuzzy sliding mode controllers. The two-time scale design approach minimizes the effect of boundary layer system on the full order system. A stability analysis allows us to provide sufficient conditions for the asymptotic stability of the full order closed-loop system. The simulation results show improved system performance of the proposed controller as compared to existing methods. The experimentation results validate the effectiveness of the proposed controller. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  7. A novel adaptive switching function on fault tolerable sliding mode control for uncertain stochastic systems.

    PubMed

    Zahiripour, Seyed Ali; Jalali, Ali Akbar

    2014-09-01

    A novel switching function based on an optimization strategy for the sliding mode control (SMC) method has been provided for uncertain stochastic systems subject to actuator degradation such that the closed-loop system is globally asymptotically stable with probability one. In the previous researches the focus on sliding surface has been on proportional or proportional-integral function of states. In this research, from a degree of freedom that depends on designer choice is used to meet certain objectives. In the design of the switching function, there is a parameter which the designer can regulate for specified objectives. A sliding-mode controller is synthesized to ensure the reachability of the specified switching surface, despite actuator degradation and uncertainties. Finally, the simulation results demonstrate the effectiveness of the proposed method. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  8. Application of whole slide image markup and annotation for pathologist knowledge capture.

    PubMed

    Campbell, Walter S; Foster, Kirk W; Hinrichs, Steven H

    2013-01-01

    The ability to transfer image markup and annotation data from one scanned image of a slide to a newly acquired image of the same slide within a single vendor platform was investigated. The goal was to study the ability to use image markup and annotation data files as a mechanism to capture and retain pathologist knowledge without retaining the entire whole slide image (WSI) file. Accepted mathematical principles were investigated as a method to overcome variations in scans of the same glass slide and to accurately associate image markup and annotation data across different WSI of the same glass slide. Trilateration was used to link fixed points within the image and slide to the placement of markups and annotations of the image in a metadata file. Variation in markup and annotation placement between WSI of the same glass slide was reduced from over 80 μ to less than 4 μ in the x-axis and from 17 μ to 6 μ in the y-axis (P < 0.025). This methodology allows for the creation of a highly reproducible image library of histopathology images and interpretations for educational and research use.

  9. Automated classification of brain tumor type in whole-slide digital pathology images using local representative tiles.

    PubMed

    Barker, Jocelyn; Hoogi, Assaf; Depeursinge, Adrien; Rubin, Daniel L

    2016-05-01

    Computerized analysis of digital pathology images offers the potential of improving clinical care (e.g. automated diagnosis) and catalyzing research (e.g. discovering disease subtypes). There are two key challenges thwarting computerized analysis of digital pathology images: first, whole slide pathology images are massive, making computerized analysis inefficient, and second, diverse tissue regions in whole slide images that are not directly relevant to the disease may mislead computerized diagnosis algorithms. We propose a method to overcome both of these challenges that utilizes a coarse-to-fine analysis of the localized characteristics in pathology images. An initial surveying stage analyzes the diversity of coarse regions in the whole slide image. This includes extraction of spatially localized features of shape, color and texture from tiled regions covering the slide. Dimensionality reduction of the features assesses the image diversity in the tiled regions and clustering creates representative groups. A second stage provides a detailed analysis of a single representative tile from each group. An Elastic Net classifier produces a diagnostic decision value for each representative tile. A weighted voting scheme aggregates the decision values from these tiles to obtain a diagnosis at the whole slide level. We evaluated our method by automatically classifying 302 brain cancer cases into two possible diagnoses (glioblastoma multiforme (N = 182) versus lower grade glioma (N = 120)) with an accuracy of 93.1% (p < 0.001). We also evaluated our method in the dataset provided for the 2014 MICCAI Pathology Classification Challenge, in which our method, trained and tested using 5-fold cross validation, produced a classification accuracy of 100% (p < 0.001). Our method showed high stability and robustness to parameter variation, with accuracy varying between 95.5% and 100% when evaluated for a wide range of parameters. Our approach may be useful to automatically differentiate between the two cancer subtypes. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Integrated Data Collection and Analysis Project: Friction Correlation Study

    DTIC Science & Technology

    2015-08-01

    methods authorized in AOP-7 include Pendulum Friction, Rotary Friction, Sliding Friction (ABL), BAM Friction and Steel/Fiber Shoe Methods. The...sensitivity can be obtained by Pendulum Friction, Rotary Friction, Sliding Friction (such as the ABL), BAM Friction and Steel/Fiber Shoe Methods.3, 4 Within...Figure 4.16 A variable compressive force is applied downward through the wheel hydraulically (50-1995 psi). The 5 kg pendulum impacts (8 ft/sec is the

  11. The bovine immune response to Brucella abortus. II. Elimination of some sporadic serological reactions by chelation of divalent cations.

    PubMed Central

    Nielsen, K; Samagh, B S; Speckmann, G; Stemshorn, B

    1979-01-01

    The standard agglutination tests for detecting antibody to Brucella abortus were modified by addition of chelating agents (EDTA and EGTA) to the antigens. Approximately 80% of "singleton" agglutination test reactions, negative on the diagnostic complement fixation test, obtained with cattle sera were eliminated while no decrease in titer was apparent when sera from B. abortus infected or vaccinated cattle were tested. PMID:121242

  12. STUDIES ON THE ANTIGENIC PROPERTIES OF COMPLEMENT

    PubMed Central

    Klein, Paul G.; Burkholder, Peter M.

    1960-01-01

    Sheep erythrocytes sensitized with amboceptor and persensitized thereafter with guinea pig complement are agglutinated by rabbit anti-guinea pig globulin and by immune sera obtained by injection of rabbits with fixed complement. In this agglutination neither C'1 nor C'2 takes part. Fixed C'4 acts as an agglutinogen. An additional agglutinogen, distinct from C'4, was found on persensitized cells. This additional agglutinogen appears to be distinct from hemolytically active C'3. PMID:14409703

  13. Comparison of the H7 latex agglutination test with a fliCh7 real-time PCR assay for confirmation of the H type of Escherichia coli O157:H7

    USDA-ARS?s Scientific Manuscript database

    Escherichia coli O157:H7 is a food-borne pathogen that causes hemorrhagic colitis and hemolytic uremic syndrome. Positive identification of E. coli O157:H7 is made using biochemical tests and latex agglutination using specific antisera. However, under certain conditions, some E. coli O157:H7 isolate...

  14. Humoral responses in human organ transplantation

    PubMed Central

    Waller, Marion; Pierce, J. C.; Moncure, C. W.; Hume, D. M.

    1972-01-01

    The plasmas of fifteen patients undergoing organ transplantation were serially tested for a variety of humoral antibodies. The antibodies studied were those which usually reflect covert immunologic events, i.e. the antiglobulins (rheumatoid factors and serum agglutinators), heterophile antibodies and typical and atypical isoantibodies. Although the isoantibodies and the heterophile antibodies were not significantly stimulated by organ transplantation, the administration of ALG (horse antilymphocyte globulin) invariably led to the presence of antihorse globulin antibodies. Three patients were Rh negative and received organs from Rh-positive donors. However, only one of the patients responded with anti-Rh antibodies, but these antibodies exceeded in titre the anti-Rh antibodies usually observed following intentional immunization of normal volunteers. The most startling observation was the significant increase in titres of the serum agglutinators in eight of the patients. These observations suggest that the antigen–antibody complexes associated with chronic rejection may stimulate the production of the serum agglutinators. PMID:4625156

  15. Assessment of red blood cell parameters and peripheral smear at different temperatures in case of cold agglutination disease.

    PubMed

    Gupta, V

    2014-03-01

    Cold agglutination disease (CAD) is characterized by an auto-antibody which is able to agglutinate red blood cells (RBCs) at temperatures lower than that of the body, and subsequently to activate the complement system responsible for lysis of RBCs. Patients show hemolytic anemia of varying degrees of severity, which arise or worsen upon exposure to low temperatures. We describe a case who presented with fever and symptoms of asthenia. His investigations yielded bizarre RBC parameters which led to suspicion of a rare CAD, which was confirmed on reviewing RBC parameters, peripheral smear and direct Coomb's test at different temperatures. Hence, we suggest assessment of bizarre RBC parameters and peripheral smear can help in laboratory testing and diagnosis of CAD. It should also not pose embarrassment in laboratory testing to the pathologist for making an early and accurate diagnosis, thus emphasizing the need for an early treatment of CAD.

  16. Evaluation of a latex agglutination assay for the identification of Burkholderia pseudomallei and Burkholderia mallei.

    PubMed

    Duval, Brea D; Elrod, Mindy G; Gee, Jay E; Chantratita, Narisara; Tandhavanant, Sarunporn; Limmathurotsakul, Direk; Hoffmaster, Alex R

    2014-06-01

    Cases of melioidosis and glanders are rare in the United States, but the etiologic agents of each disease (Burkholderia pseudomallei and Burkholderia mallei, respectively) are classified as Tier 1 select agents because of concerns about their potential use as bioterrorism agents. A rapid, highly sensitive, and portable assay for clinical laboratories and field use is required. Our laboratory has further evaluated a latex agglutination assay for its ability to identify B. pseudomallei and B. mallei isolates. This assay uses a monoclonal antibody that specifically recognizes the capsular polysaccharide produced by B. pseudomallei and B. mallei, but is absent in closely related Burkholderia species. A total of 110 B. pseudomallei and B. mallei were tested, and 36 closely related Burkholderia species. The latex agglutination assay was positive for 109 of 110 (99.1% sensitivity) B. pseudomallei and B. mallei isolates tested. © The American Society of Tropical Medicine and Hygiene.

  17. Stratigraphy and depositional history of the Apollo 17 drill core

    NASA Technical Reports Server (NTRS)

    Taylor, G. J.; Warner, R. D.; Keil, K.

    1979-01-01

    Lithologic abundances obtained from modal analyses of a continuous string of polished thin sections indicate that the Apollo 17 deep drill core can be divided into three main zones: An upper zone (0-19 cm depth) characterized by high abundances of agglutinates (30%) and a high ratio of mare to non-mare lithic fragments (less than 0.8); a coarse-grained layer (24-56 cm) rich in fragments of high-Ti mare basalts and mineral fragments derived from them, and poor in agglutinates (6%); and a lower zone (56-285 cm) characterized by variable but generally high agglutinate abundances (25%) and a low ratio of mare to nonmare lithic fragments (0.6). Using observations of the geology of the landing site, the principles of cratering dynamics, and the vast amount of data collected on the core, the following depositional history for the section of regolith sampled by the Apollo 17 drill core: was devised.

  18. SEROLOGICAL TYPING OF STAPHYLOCOCCI BY MEANS OF FLUORESCENT ANTIBODIES I.

    PubMed Central

    Cohen, Jay O.; Oeding, Per

    1962-01-01

    Cohen, Jay O. (Communicable Disease Center, Atlanta, Ga.) and Per Oeding. Serological typing of staphylococci by means of fluorescent antibodies. I. Development of specific reagents for seven serological factors. J. Bacteriol. 84:735–741. 1962—Fluorescent antibody reagents for identifying seven antigenic factors of staphylococci have been prepared. The fluorescent staining reactions of these reagents were compared to the agglutination reactions with diagnostic cultures of coagulase-positive staphylococci. Correlation between the two serological tests was almost complete with factors a, b, i, and k. The c fluorescent antibody reagent had a somewhat broader spectrum of activity than the corresponding agglutination serum, whereas the m fluorescent antibody reagent stained fewer strains than were agglutinated in m serum. The fluorescent antibody reagent for h factor stained strains possessing h1 factor but not strains possessing only h2 factor. Fluorescent antibody reagents for specific staphylococcal factors did not stain strains of group A streptococci. PMID:14022057

  19. Directional acceleration vector-driven displacement of fluids (DAVD-DOF)

    NASA Technical Reports Server (NTRS)

    Clarke, Mark S. F. (Inventor); Feeback, Daniel L. (Inventor)

    2004-01-01

    Centrifugal analyzer and method for staining biological or non-biological samples in microgravity, wherein the method utilizes an increase in weight of a fluid sample as a function of g-load, to overcome cohesive and frictional forces from preventing its movement in a preselected direction. Apparatus is characterized by plural specimen reservoirs and channels in a slide, each channel being of differing cross-section, wherein respective samples are selectively dispensed, from the reservoirs in response to an imposed g-factor, precedent to sample staining. Within the method, one thus employs microscope slides which define channels, each being of a differing cross-section dimension relative to others. In combination therewith, centrifugal slide mounting apparatus controllably imposes g-vectors of differing magnitudes within a defined structure of the centrifuge such as a chip array.

  20. Terminal Sliding Mode-Based Consensus Tracking Control for Networked Uncertain Mechanical Systems on Digraphs.

    PubMed

    Chen, Gang; Song, Yongduan; Guan, Yanfeng

    2018-03-01

    This brief investigates the finite-time consensus tracking control problem for networked uncertain mechanical systems on digraphs. A new terminal sliding-mode-based cooperative control scheme is developed to guarantee that the tracking errors converge to an arbitrarily small bound around zero in finite time. All the networked systems can have different dynamics and all the dynamics are unknown. A neural network is used at each node to approximate the local unknown dynamics. The control schemes are implemented in a fully distributed manner. The proposed control method eliminates some limitations in the existing terminal sliding-mode-based consensus control methods and extends the existing analysis methods to the case of directed graphs. Simulation results on networked robot manipulators are provided to show the effectiveness of the proposed control algorithms.

  1. An entirely automated method to score DSS-induced colitis in mice by digital image analysis of pathology slides

    PubMed Central

    Kozlowski, Cleopatra; Jeet, Surinder; Beyer, Joseph; Guerrero, Steve; Lesch, Justin; Wang, Xiaoting; DeVoss, Jason; Diehl, Lauri

    2013-01-01

    SUMMARY The DSS (dextran sulfate sodium) model of colitis is a mouse model of inflammatory bowel disease. Microscopic symptoms include loss of crypt cells from the gut lining and infiltration of inflammatory cells into the colon. An experienced pathologist requires several hours per study to score histological changes in selected regions of the mouse gut. In order to increase the efficiency of scoring, Definiens Developer software was used to devise an entirely automated method to quantify histological changes in the whole H&E slide. When the algorithm was applied to slides from historical drug-discovery studies, automated scores classified 88% of drug candidates in the same way as pathologists’ scores. In addition, another automated image analysis method was developed to quantify colon-infiltrating macrophages, neutrophils, B cells and T cells in immunohistochemical stains of serial sections of the H&E slides. The timing of neutrophil and macrophage infiltration had the highest correlation to pathological changes, whereas T and B cell infiltration occurred later. Thus, automated image analysis enables quantitative comparisons between tissue morphology changes and cell-infiltration dynamics. PMID:23580198

  2. Enhanced post wash retention of combed DNA molecules by varying multiple combing parameters.

    PubMed

    Yadav, Hemendra; Sharma, Pulkit

    2017-11-01

    Recent advances in genomics have created a need for efficient techniques for deciphering information hidden in various genomes. Single molecule analysis is one such technique to understand molecular processes at single molecule level. Fiber- FISH performed with the help of DNA combing can help us in understanding genetic rearrangements and changes in genome at single DNA molecule level. For performing Fiber-FISH we need high retention of combed DNA molecules post wash as Fiber-FISH requires profuse washing. We optimized combing process involving combing solution, method of DNA mounting on glass slides and coating of glass slides to enhance post-wash retention of DNA molecules. It was found that average number of DNA molecules observed post-wash per field of view was maximum with our optimized combing solution. APTES coated glass slides showed lesser retention than PEI surface but fluorescent intensity was higher in case of APTES coated surface. Capillary method used to mount DNA on glass slides also showed lesser retention but straight DNA molecules were observed as compared to force flow method. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Performance of a malaria microscopy image analysis slide reading device

    PubMed Central

    2012-01-01

    Background Viewing Plasmodium in Romanovsky-stained blood has long been considered the gold standard for diagnosis and a cornerstone in management of the disease. This method however, requires a subjective evaluation by trained, experienced diagnosticians and establishing proficiency of diagnosis is fraught with many challenges. Reported here is an evaluation of a diagnostic system (a “device” consisting of a microscope, a scanner, and a computer algorithm) that evaluates scanned images of standard Giemsa-stained slides and reports species and parasitaemia. Methods The device was challenged with two independent tests: a 55 slide, expert slide reading test the composition of which has been published by the World Health Organization (“WHO55” test), and a second test in which slides were made from a sample of consenting subjects participating in a malaria incidence survey conducted in Equatorial Guinea (EGMIS test). These subjects’ blood was tested by malaria RDT as well as having the blood smear diagnosis unequivocally determined by a worldwide panel of a minimum of six reference microscopists. Only slides with unequivocal microscopic diagnoses were used for the device challenge, n = 119. Results On the WHO55 test, the device scored a “Level 4” using the WHO published grading scheme. Broken down by more traditional analysis parameters this result was translated to 89% and 70% sensitivity and specificity, respectively. Species were correctly identified in 61% of the slides and the quantification of parasites fell within acceptable range of the validated parasitaemia in 10% of the cases. On the EGMIS test it scored 100% and 94% sensitivity/specificity, with 64% of the species correct and 45% of the parasitaemia within an acceptable range. A pooled analysis of the 174 slides used for both tests resulted in an overall 92% sensitivity and 90% specificity with 61% species and 19% quantifications correct. Conclusions In its current manifestation, the device performs at a level comparable to that of many human slide readers. Because its use requires minimal additional equipment and it uses standard stained slides as starting material, its widespread adoption may eliminate the current uncertainty about the quality of microscopic diagnoses worldwide. PMID:22559294

  4. Evaluation of a New and Rapid Serologic Test for Detecting Brucellosis: Brucella Coombs Gel Test.

    PubMed

    Hanci, Hayrunisa; Igan, Hakan; Uyanik, Muhammet Hamidullah

    2017-01-01

    Many serological tests have been used for the diagnosis of human brucellosis. A new serological method is identified as Brucella Coombs gel test based on the principle of centrifugation gel system similar to the gel system used in blood group determination. In this system, if Brucella antibodies were present in the serum, antigen and antibody would remain as a pink complex on the gel. Otherwise, the pink Brucella antigens would precipitate at the bottom of the gel card system. In this study, we aimed to compare the Brucella Coombs gel test, a new, rapid screen and titration method for detection of non-agglutinating IgG with the Brucella Coombs test. For this study, a total of 88 serum samples were obtained from 45 healthy persons and 43 individuals who had clinical signs and symptoms of brucellosis. For each specimen, Rose Bengal test, standard agglutination test, Coombs test and Brucella Coombs gel test were carried out. Sensitivity and specificity of Brucella Coombs gel test were found as 100.0 and 82.2%, respectively. Brucella Coombs gel test can be used as a screening test with high sensitivity. By the help of pink Brucella antigen precipitation, the tests' evaluation is simple and objective. In addition, determination of Brucella antibody by rapid titration offers another important advantage.

  5. Routine Digital Pathology Workflow: The Catania Experience

    PubMed Central

    Fraggetta, Filippo; Garozzo, Salvatore; Zannoni, Gian Franco; Pantanowitz, Liron; Rossi, Esther Diana

    2017-01-01

    Introduction: Successful implementation of whole slide imaging (WSI) for routine clinical practice has been accomplished in only a few pathology laboratories worldwide. We report the transition to an effective and complete digital surgical pathology workflow in the pathology laboratory at Cannizzaro Hospital in Catania, Italy. Methods: All (100%) permanent histopathology glass slides were digitized at ×20 using Aperio AT2 scanners. Compatible stain and scanning slide racks were employed to streamline operations. eSlide Manager software was bidirectionally interfaced with the anatomic pathology laboratory information system. Virtual slide trays connected to the two-dimensional (2D) barcode tracking system allowed pathologists to confirm that they were correctly assigned slides and that all tissues on these glass slides were scanned. Results: Over 115,000 glass slides were digitized with a scan fail rate of around 1%. Drying glass slides before scanning minimized them sticking to scanner racks. Implementation required introduction of a 2D barcode tracking system and modification of histology workflow processes. Conclusion: Our experience indicates that effective adoption of WSI for primary diagnostic use was more dependent on optimizing preimaging variables and integration with the laboratory information system than on information technology infrastructure and ensuring pathologist buy-in. Implementation of digital pathology for routine practice not only leveraged the benefits of digital imaging but also creates an opportunity for establishing standardization of workflow processes in the pathology laboratory. PMID:29416914

  6. Development of a standardized testing system for orthodontic sliding mechanics.

    PubMed

    Fathimani, Maryam; Melenka, Garrett W; Romanyk, Dan L; Toogood, Roger W; Heo, Giseon; Carey, Jason P; Major, Paul W

    2015-01-01

    The primary objective of this study was to develop a computer-controlled three-dimensional friction measuring system, the orthodontic friction simulator (OFS). A clinically-based in vitro experiment considering wet and dry friction for conventionally and self-ligated brackets is presented to elucidate debate surrounding sliding mechanics and illustrate capabilities of the OFS. The OFS was designed and manufactured using sound engineering principles and with the primary concern of being able to measure all forces and moments generated during sliding mechanics. This required the implementation of a six-axis load cell. A variety of translation and rotation stages were also incorporated to allow for precise positioning of the bracket relative to the archwire. Once designed and built, the OFS was then used to compare conventional and self-ligation methods in both the wet and dry state. Damon Q brackets and 0.018″ × 0.025″ stainless steel wires were used for all tests with a sample size of n = 65 for each ligation method. Archwires were pulled at a speed of 0.1 mm/s in 11 increments of 0.1 mm. At each increment, the bracket would be rotated 0.5° resulting in a total archwire travel of 1.1 mm and a second-order bracket angle range of 0°-5°. A repeated measures ANOVA was conducted to determine if ligation method and/or addition of moisture effected resulting orthodontic loads. The developed equipment for studying orthodontic sliding mechanics was able to measure forces and moments in all three directions; a capability not previously realized in the literature. Additionally, it was found that passive ligation significantly reduced resistance to sliding, P ≤ 0.05, while the dry/wet state did not. The OFS certainly proved to be an adequate instrument for the scientific evaluation of orthodontic sliding mechanics. It is capable of measuring loads generated in all directions and is a fully automated apparatus allowing for simple and repeatable friction tests to be conducted. Furthermore, the addition of saliva was not found to significantly influence the loads generated during sliding mechanics regardless of ligation method.

  7. Image microarrays (IMA): Digital pathology's missing tool

    PubMed Central

    Hipp, Jason; Cheng, Jerome; Pantanowitz, Liron; Hewitt, Stephen; Yagi, Yukako; Monaco, James; Madabhushi, Anant; Rodriguez-canales, Jaime; Hanson, Jeffrey; Roy-Chowdhuri, Sinchita; Filie, Armando C.; Feldman, Michael D.; Tomaszewski, John E.; Shih, Natalie NC.; Brodsky, Victor; Giaccone, Giuseppe; Emmert-Buck, Michael R.; Balis, Ulysses J.

    2011-01-01

    Introduction: The increasing availability of whole slide imaging (WSI) data sets (digital slides) from glass slides offers new opportunities for the development of computer-aided diagnostic (CAD) algorithms. With the all-digital pathology workflow that these data sets will enable in the near future, literally millions of digital slides will be generated and stored. Consequently, the field in general and pathologists, specifically, will need tools to help extract actionable information from this new and vast collective repository. Methods: To address this limitation, we designed and implemented a tool (dCORE) to enable the systematic capture of image tiles with constrained size and resolution that contain desired histopathologic features. Results: In this communication, we describe a user-friendly tool that will enable pathologists to mine digital slides archives to create image microarrays (IMAs). IMAs are to digital slides as tissue microarrays (TMAs) are to cell blocks. Thus, a single digital slide could be transformed into an array of hundreds to thousands of high quality digital images, with each containing key diagnostic morphologies and appropriate controls. Current manual digital image cut-and-paste methods that allow for the creation of a grid of images (such as an IMA) of matching resolutions are tedious. Conclusion: The ability to create IMAs representing hundreds to thousands of vetted morphologic features has numerous applications in education, proficiency testing, consensus case review, and research. Lastly, in a manner analogous to the way conventional TMA technology has significantly accelerated in situ studies of tissue specimens use of IMAs has similar potential to significantly accelerate CAD algorithm development. PMID:22200030

  8. The Use of Various Failure Criteria as Applied to High Speed Wear

    DTIC Science & Technology

    2011-12-01

    This research has been aimed at developing methods to predict mechanical wear of sliding bodies at high velocities. Specifically, wear of test sled...Several failure criteria were evaluated as possible methods to estimate damaged material from the sliding body . The Johnson and Cook constitutive...Data [11] . . . . . . . . . . . . . 12 1.11. Finite Element Model Used by Burton [11] . . . . . . . . . . . 12 1.12. HHSTT Third Stage Velocity

  9. Carbon nanotube/biocompatible bola-amphiphile supramolecular biohybrid materials: preparation and their application in bacterial cell agglutination.

    PubMed

    Yu, Guocan; Li, Jinying; Yu, Wei; Han, Chengyou; Mao, Zhengwei; Gao, Changyou; Huang, Feihe

    2013-11-26

    Supramolecular biohybrid materials were successfully constructed driven by non-covalent interactions between three biocompatible bolaform amphiphiles and single walled carbon nanotubes (SWNTs). The existence of galactoses in these supramolecular systems endowed the hybrid materials with interesting bio-function. By introducing the SWNTs as semi-flexible platforms, these supramolecular biohybrid materials display excellent agglutination ability for E. coli. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. The utility of direct agglutination (DAT) and fast agglutination screening (FAST) tests in serodiagnosis of experimental microsporidiosis.

    PubMed

    Abou El Naga, Iman F; Gaafar, Maha R; El-Zawawy, Lobna A; El-Said, Doaa; Mossallam, Sherin F

    2008-12-01

    The present study was designed to evaluate the efficiency of two serodiagnostic tests; the direct agglutination test (DAT) and the fast agglutination screening test (FAST) in the diagnosis of Microsporidia in experimentally infected mice and to differentiate between different species of the parasite. The swiss albino mice were divided into non infected control and infected experimental groups which were further subdivided into ten subgroups. Ten samples of microsporidial spores were isolated from ten human stools and each one was used to infect each subgroup of mice. Stool and sera were collected weekly from each subgroup from the 1st to the 4th week post infection (PI). DAT & FAST tests, using antigen prepared from the different species of microsporidial spores were used to detect antibodies in sera of different mice subgroups. The cross reactivity of microsporidial spores with the antibodies of Cyclospora cyatenensis and Cryptosporidium parvum was investigated by DAT & FAST. The results proved that DAT & FAST were effective in detecting microsporidial antibodies in sera of experimentally infected mice from the 2nd week PI till the end of the study, without cross reactivity with C. cyatenensis or C. parvum. They failed to differentiate between different Microspoiridia species used but, they gave good interpretation and they were specific and sensitive, and did not need sophisticated equipments.

  11. Protection against Escherichia coli K1 infection in newborn rats by antibody to K1 capsular polysaccharide antigen.

    PubMed

    Bortolussi, R; Ferrier, P

    1980-04-01

    The protective value of antibody to the K1 capsular polysaccharide antigen of Escherichia coli was investigated in a newborn rat model of E. coli K1 infection. Pregnant rats were immunized intravenously with E. coli, and the agglutinating titer to meningococcal group B polysaccharide, which is identical to K1 polysaccharide, was measured in the serum of rats and their offspring. Convalescent serum from rat mothers showed an increased antibody titer in animals injected twice but not once with E. coli K1. Although no agglutinating antibody was detected in the serum of rat pups, animals suckled by mothers having a meningococcal group B agglutinating titer of 1:8 or greater had reduced infection and mortality rates after intraperitoneal injection with E. coli K1 compared with animals suckled by mothers having a low titer of agglutinating antibody (P less than 0.05). In addition, greater protection could be conferred on rat sucklings by oral supplementation with a horse serum rich in antibody to meningococcal group B polysaccharide, suggesting that antibody was abosorbed from the gastrointestinal tract and by itself could be protective. These studies demonstrated that antibody to the capsular polysaccharide of E. coli K1 altered the severity of E. coli K1 infection. Final clearance of bacteria from the blood appeared to await the maturation of other host defense systems in the newborn rat.

  12. Reciprocal Sliding Friction Model for an Electro-Deposited Coating and Its Parameter Estimation Using Markov Chain Monte Carlo Method

    PubMed Central

    Kim, Kyungmok; Lee, Jaewook

    2016-01-01

    This paper describes a sliding friction model for an electro-deposited coating. Reciprocating sliding tests using ball-on-flat plate test apparatus are performed to determine an evolution of the kinetic friction coefficient. The evolution of the friction coefficient is classified into the initial running-in period, steady-state sliding, and transition to higher friction. The friction coefficient during the initial running-in period and steady-state sliding is expressed as a simple linear function. The friction coefficient in the transition to higher friction is described with a mathematical model derived from Kachanov-type damage law. The model parameters are then estimated using the Markov Chain Monte Carlo (MCMC) approach. It is identified that estimated friction coefficients obtained by MCMC approach are in good agreement with measured ones. PMID:28773359

  13. Finite-time output feedback control of uncertain switched systems via sliding mode design

    NASA Astrophysics Data System (ADS)

    Zhao, Haijuan; Niu, Yugang; Song, Jun

    2018-04-01

    The problem of sliding mode control (SMC) is investigated for a class of uncertain switched systems subject to unmeasurable state and assigned finite (possible short) time constraint. A key issue is how to ensure the finite-time boundedness (FTB) of system state during reaching phase and sliding motion phase. To this end, a state observer is constructed to estimate the unmeasured states. And then, a state estimate-based SMC law is designed such that the state trajectories can be driven onto the specified integral sliding surface during the assigned finite time interval. By means of partitioning strategy, the corresponding FTB over reaching phase and sliding motion phase are guaranteed and the sufficient conditions are derived via average dwell time technique. Finally, an illustrative example is given to illustrate the proposed method.

  14. New methods of pregnancy testing in adolescent girls.

    PubMed

    Saxena, B B

    1981-05-01

    The knowledge and use of newer, more sensitive, and reliable pregnancy tests which are easily accessible and of moderate cost are the 1st steps in the early diagnosis and management of pregnancy, especially in adolescent girls. Accurate diagnosis of pregnancy soon after conception offers the option of abortion by simple, effective, and inexpensive procedures or early initiation of prenatal maternity care. Discussion focuses on the symptoms of pregnancy and the historical development and basis of pregnancy tests as well as the specific types of pregnancy tests. The most familiar sign of pregnancy is the missed period. Other symptoms that provide presumptive evidence of pregnancy include fatigue and lassitude, increased body temperature, and breast fullness or pain. Feelings of nausea, vomiting, and weight gain may appear after 2 weeks. The diagnosis of pregnancy by the detection of the human chorionic gonadotropin was initially described 53 years ago by Selmar Aschheim and Bernhardt Zondek. Improvements in the techniques for the measurement of human chorionic gonadotropin (hCG) have been directly related to the progress in the purification and isolation of hCG and elucidation of the amino acid sequence of the hormone-nonspecific alpha subunit and hormone-specific beta subunit of hCG. The history, physical examination, and pregnancy tests will generally provide sufficient information for a definite diagnosis of pregnancy. The presence of hCG in the urine or blood is the most accurate of all the indications of pregnancy. During the last century, 4 different techniques for the determination of hCG in blood and/or urine have been developed. These include the following and are reviewed in detail: 1) bioassays in intact laboratory animals; 2) immunologic tube or slide methods with heme- or latex-agglutination inhibition, as well as the more recently developed competitive protein binding method such as 3) radioimmunoassay (RIA) for the use of radioisotope labeled hormone and the specific antiserum against hCG; and 4) radioreceptorassay by the use of radioisotope-labeled hormone with biological activity and the specific receptors as the binding proteins.

  15. Comparing whole slide digital images versus traditional glass slides in the detection of common microscopic features seen in dermatitis

    PubMed Central

    Vyas, Nikki S.; Markow, Michael; Prieto-Granada, Carlos; Gaudi, Sudeep; Turner, Leslie; Rodriguez-Waitkus, Paul; Messina, Jane L.; Jukic, Drazen M.

    2016-01-01

    Background: The quality and limitations of digital slides are not fully known. We aimed to estimate intrapathologist discrepancy in detecting specific microscopic features on glass slides and digital slides created by scanning at ×20. Methods: Hematoxylin and eosin and periodic acid–Schiff glass slides were digitized using the Mirax Scan (Carl Zeiss Inc., Germany). Six pathologists assessed 50–71 digital slides. We recorded objective magnification, total time, and detection of the following: Mast cells; eosinophils; plasma cells; pigmented macrophages; melanin in the epidermis; fungal bodies; neutrophils; civatte bodies; parakeratosis; and sebocytes. This process was repeated using the corresponding glass slides after 3 weeks. The diagnosis was not required. Results: The mean time to assess digital slides was 176.77 s and 137.61 s for glass slides (P < 0.001, 99% confidence interval [CI]). The mean objective magnification used to detect features using digital slides was 18.28 and 14.07 for glass slides (P < 0.001, 99.99% CI). Parakeratosis, civatte bodies, pigmented macrophages, melanin in the epidermis, mast cells, eosinophils, plasma cells, and neutrophils, were identified at lower objectives on glass slides (P = 0.023–0.001, 95% CI). Average intraobserver concordance ranged from κ = 0.30 to κ = 0.78. Features with poor to fair average concordance were: Melanin in the epidermis (κ = 0.15–0.58); plasma cells (κ = 0.15–0.49); and neutrophils (κ = 0.12–0.48). Features with moderate average intrapathologist concordance were: parakeratosis (κ = 0.21–0.61); civatte bodies (κ = 0.21–0.71); pigment-laden macrophages (κ = 0.34–0.66); mast cells (κ = 0.29–0.78); and eosinophils (κ = 0.31–0.79). The average intrapathologist concordance was good for sebocytes (κ = 0.51–1.00) and fungal bodies (κ = 0.47–0.76). Conclusions: Telepathology using digital slides scanned at ×20 is sufficient for detection of histopathologic features routinely encountered in dermatitis cases, though less efficient than glass slides. PMID:27563489

  16. Development of a serology-based assay for efficacy evaluation of a lactococcicosis vaccine in Seriola fish.

    PubMed

    Nakajima, Nao; Kawanishi, Michiko; Imamura, Saiki; Hirano, Fumiya; Uchiyama, Mariko; Yamamoto, Kinya; Nagai, Hidetaka; Futami, Kunihiko; Katagiri, Takayuki; Maita, Masashi; Kijima, Mayumi

    2014-05-01

    Lactococcicosis is an infection caused by the bacterium Lactococcus garvieae and creates serious economic damage to cultured marine and fresh water fish industries. The use of the assay currently applied to evaluate the potency of the lactococcicosis vaccine is contingent upon meeting specific parameters after statistical analysis of the percent survival of the vaccinated yellowtail or greater amberjack fish after challenge with a virulent strain of L. garvieae. We found that measuring the serological response with a quantitative agglutinating antibody against the L. garvieae antigen (phenotype KG+) was an effective method of monitoring the potency of lactococcicosis vaccines. Vaccinated fish had significantly higher antibody titers than control fish when the L. garvieae Lg2-S strain was used as an antigen. Furthermore, the titer of the KG + agglutinating antibody was correlated with vaccine potency, and the cut-off titer was determined by comparing the data with those from the challenge test. An advantage of the proposed serology-based potency assay is that it will contribute to reduced numbers of animal deaths during vaccine potency evaluations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. INFECTIOUS MYXOMATOSIS OF RABBITS

    PubMed Central

    Rivers, Thomas M.; Ward, S. M.

    1937-01-01

    From the results of the experiments described in this paper it is obvious that large amounts of elementary bodies of myxoma can be obtained in a relatively pure state by means of the methods used. Furthermore, it is evident that infectious myxomatosis is a viral disease in which elementary bodies of the same order of magnitude as vaccinal elementary bodies play a conspicuous rô1e in that they either represent the etiological agent or are intimately associated with it. The bodies are specifically agglutinated by antimyxoma serum and are agglutinated to a less extent by serum from rabbits convalescing from fibroma, a disease closely related to myxoma. In virus-free filtrates of emulsions prepared from infected skin there is a soluble precipitinogen or precipitinogens specific for the malady. Moreover, a specific precipitinogen or precipitinogens are demonstrable in virus-free serum of animals acutely ill as a result of extensive infection with myxoma virus. It is believed that this is the second viral disease, yellow fever (14) being the first, in which a specific soluble antigen free from virus has been found in the serum of ill animals. PMID:19870643

  18. Rocket and Two Dimensional Immunoelectrophoresis in Diagnosis of Caprine Brucellosis

    PubMed Central

    MEHRABANI, Davood; GHOLAMI, Zahra; KOHANTEB, Jamshid; SEPEHRIMANESH, Masood; HOSSEINI, Seyed Mohammad Hossein

    2015-01-01

    Background: Brucellosis is a major bacterial zoonosis of global importance with the causative organisms of Gram-negative facultative intracellular pathogens. The aims of this study were to standardize two immunoelectrophoretic techniques, rocket and cross immunoelectrophoresis, and compare their results with other conventional serodiagnostic tests. Methods: Sera from 15 sheep, without any history of brucellosis vaccination, infected with Brucella melitensis M16 subcutaneously, were employed in a comparison of culture, precipitating, and immunoelectrophoretic tests. A 125 days serologic follow-up was performed after the infection was started. As a reference, these tests also done in the five healthy sheep. Results: The results obtained with the rocket immunoelectrophoresis test correlated very well with those of the cross immunoelectrophoresis, whereas results of other tests such as culture, Rose Bengal, standard tube agglutination and 2-mercaptoethanol seruagglutination tests were inferior. Conclusion: As agglutination test shows cross reaction and a prozone phenomenon, and in blood culture, the bacteria is not always detectable, so they are time consuming rocket and cross immunoelectrophoresis are recommended because their results can be obtained in a shorter time. PMID:26587475

  19. INRA, a new high-frequency antigen in the INDIAN (IN023) blood group system.

    PubMed

    Joshi, Sanmukh R; Sheladiya, Ankita; Mendapara-Dobariya, Kinjal V

    2017-01-01

    The INDIAN blood group system comprises 4 antigens sensitive to enzymes and 2-aminoethyl isothiouronium bromide (AET). The patient's antibody was investigated for its specificity to the high-frequency antigens (HFA) of this system. Low ionic strength solution (LISS)-tube/LISS-indirect antiglobulin test (IAT) methods were used. The patient's red blood cells (RBCs) were tested with antisera to HFA. Her antibody was tested with RBCs lacking the HFA. Furthermore, it was tested with RBCs as untreated or treated with enzyme or AET. The genetic sequence was studied for mutation in CD44 gene that encodes INDIAN antigens. The patient was grouped A1B, RhD+, antibody screening test positive, direct antiglobulin test negative. A negative autocontrol test had suggested to the alloantibody being present. Antibody had agglutinated RBCs in LISS-tube at RT and by LISS-IAT at 37°C. The RBCs of the 11-cell panel, those lacking HFA and from 50 random donors, were agglutinated by her antibody indicating its specificity to the HFA, though the RBCs of Lu (a-b-)/In (Lu) type showed a weaker reaction. The patient's RBCs were agglutinated by antisera to a number of the enzyme-sensitive HFA, including those of INDIAN blood groups. The antibody showed reduced reactivity with the RBCs treated with papain, chymotrypsin, and AET but resistant to trypsin and dithiothreitol. The patient's genetic sequence revealed a novel homozygous mutation 449G>A in exon 5 of CD44 . The antibody to enzyme sensitive HFA was tested for serological and molecular genetics studies and found to be directed to the novel HFA, named as INRA of the INDIAN blood group system and was assigned a numerical symbol IN: 005 by the International Society of Blood Transfusion (ISBT).

  20. New Laboratory Observations of Thermal Pressurization Weakening

    NASA Astrophysics Data System (ADS)

    Badt, N.; Tullis, T. E.; Hirth, G.

    2017-12-01

    Dynamic frictional weakening due to pore fluid thermal pressurization has been studied under elevated confining pressure in the laboratory, using a rotary-shear apparatus having a sample with independent pore pressure and confining pressure systems. Thermal pressurization is directly controlled by the permeability of the rocks, not only for the initiation of high-speed frictional weakening but also for a subsequent sequence of high-speed sliding events. First, the permeability is evaluated at different effective pressures using a method where the pore pressure drop and the flow-through rate are compared using Darcy's Law as well as a pore fluid oscillation method, the latter method also permitting measurement of the storage capacity. Then, the samples undergo a series of high-speed frictional sliding segments at a velocity of 2.5 mm/s, under an applied confining pressure and normal stress of 45 MPa and 50 MPa, respectively, and an initial pore pressure of 25 MPa. Finally the rock permeability and storage capacity are measured again to assess the evolution of the rock's pore fluid properties. For samples with a permeability of 10-20 m2 thermal pressurization promotes a 40% decrease in strength. However, after a sequence of three high-speed sliding events, the magnitude of weakening diminishes progressively from 40% to 15%. The weakening events coincide with dilation of the sliding interface. Moreover, the decrease in the weakening degree with progressive fast-slip events suggest that the hydraulic diffusivity may increase locally near the sliding interface during thermal pressurization-enhanced slip. This could result from stress- or thermally-induced damage to the host rock, which would perhaps increase both permeability and storage capacity, and so possibly decrease the susceptibility of dynamic weakening due to thermal pressurization in subsequent high-speed sliding events.

  1. A method for quantitative analysis of clump thickness in cervical cytology slides.

    PubMed

    Fan, Yilun; Bradley, Andrew P

    2016-01-01

    Knowledge of the spatial distribution and thickness of cytology specimens is critical to the development of digital slide acquisition techniques that minimise both scan times and image file size. In this paper, we evaluate a novel method to achieve this goal utilising an exhaustive high-resolution scan, an over-complete wavelet transform across multi-focal planes and a clump segmentation of all cellular materials on the slide. The method is demonstrated with a quantitative analysis of ten normal, but difficult to scan Pap stained, Thin-prep, cervical cytology slides. We show that with this method the top and bottom of the specimen can be estimated to an accuracy of 1 μm in 88% and 97% of the fields of view respectively. Overall, cellular material can be over 30 μm thick and the distribution of cells is skewed towards the cover-slip (top of the slide). However, the median clump thickness is 10 μm and only 31% of clumps contain more than three nuclei. Therefore, by finding a focal map of the specimen the number of 1 μm spaced focal planes that are required to be scanned to acquire 95% of the in-focus material can be reduced from 25.4 to 21.4 on average. In addition, we show that by considering the thickness of the specimen, an improved focal map can be produced which further reduces the required number of 1 μm spaced focal planes to 18.6. This has the potential to reduce scan times and raw image data by over 25%. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Direct detection of Mycobacterium tuberculosis rifampin resistance in bio-safe stained sputum smears.

    PubMed

    Lavania, Surabhi; Anthwal, Divya; Bhalla, Manpreet; Singh, Nagendra; Haldar, Sagarika; Tyagi, Jaya Sivaswami

    2017-01-01

    Direct smear microscopy of sputum forms the mainstay of TB diagnosis in resource-limited settings. Stained sputum smear slides can serve as a ready-made resource to transport sputum for molecular drug susceptibility testing. However, bio-safety is a major concern during transport of sputum/stained slides and for laboratory workers engaged in processing Mycobacterium tuberculosis infected sputum specimens. In this study, a bio-safe USP (Universal Sample Processing) concentration-based sputum processing method (Bio-safe method) was assessed on 87 M. tuberculosis culture positive sputum samples. Samples were processed for Ziehl-Neelsen (ZN) smear, liquid culture and DNA isolation. DNA isolated directly from sputum was subjected to an IS6110 PCR assay. Both sputum DNA and DNA extracted from bio-safe ZN concentrated smear slides were subjected to rpoB PCR and simultaneously assessed by DNA sequencing for determining rifampin (RIF) resistance. All sputum samples were rendered sterile by Bio-safe method. Bio-safe smears exhibited a 5% increment in positivity over direct smear with a 14% increment in smear grade status. All samples were positive for IS6110 and rpoB PCR. Thirty four percent samples were RIF resistant by rpoB PCR product sequencing. A 100% concordance (κ value = 1) was obtained between sequencing results derived from bio-safe smear slides and bio-safe sputum. This study demonstrates that Bio-safe method can address safety issues associated with sputum processing, provide an efficient alternative to sample transport in the form of bio-safe stained concentrated smear slides and can also provide information on drug (RIF) resistance by direct DNA sequencing.

  3. Direct detection of Mycobacterium tuberculosis rifampin resistance in bio-safe stained sputum smears

    PubMed Central

    Lavania, Surabhi; Anthwal, Divya; Bhalla, Manpreet; Singh, Nagendra; Haldar, Sagarika; Tyagi, Jaya Sivaswami

    2017-01-01

    Direct smear microscopy of sputum forms the mainstay of TB diagnosis in resource-limited settings. Stained sputum smear slides can serve as a ready-made resource to transport sputum for molecular drug susceptibility testing. However, bio-safety is a major concern during transport of sputum/stained slides and for laboratory workers engaged in processing Mycobacterium tuberculosis infected sputum specimens. In this study, a bio-safe USP (Universal Sample Processing) concentration-based sputum processing method (Bio-safe method) was assessed on 87 M. tuberculosis culture positive sputum samples. Samples were processed for Ziehl-Neelsen (ZN) smear, liquid culture and DNA isolation. DNA isolated directly from sputum was subjected to an IS6110 PCR assay. Both sputum DNA and DNA extracted from bio-safe ZN concentrated smear slides were subjected to rpoB PCR and simultaneously assessed by DNA sequencing for determining rifampin (RIF) resistance. All sputum samples were rendered sterile by Bio-safe method. Bio-safe smears exhibited a 5% increment in positivity over direct smear with a 14% increment in smear grade status. All samples were positive for IS6110 and rpoB PCR. Thirty four percent samples were RIF resistant by rpoB PCR product sequencing. A 100% concordance (κ value = 1) was obtained between sequencing results derived from bio-safe smear slides and bio-safe sputum. This study demonstrates that Bio-safe method can address safety issues associated with sputum processing, provide an efficient alternative to sample transport in the form of bio-safe stained concentrated smear slides and can also provide information on drug (RIF) resistance by direct DNA sequencing. PMID:29216262

  4. The increased flexibility of CDR loops generated in antibodies by Congo red complexation favors antigen binding.

    PubMed

    Krol, Marcin; Roterman, Irena; Drozd, Anna; Konieczny, Leszek; Piekarska, Barbara; Rybarska, Janina; Spolnik, Paweł; Stopa, Barbara

    2006-02-01

    The dye Congo red and related self-assembling compounds were found to stabilize immune complexes by binding to antibodies currently engaged in complexation to antigen. In our simulations, it was shown that the site that becomes accessible for binding the supramolecular dye ligand is located in the V domain, and is normally occupied by the N-terminal polypeptide chain fragment. The binding of the ligand disrupts the beta-structure in the domain, increasing the plasticity of the antigen-binding site. The higher fluctuation of CDR-bearing loops enhances antigen binding, and allows even low-affinity antibodies to be engaged in immune complexes. Experimental observations of the enhancement effect were supported by theoretical studies using L lambda chain (4BJL-PDB identification) and the L chain from the complex of IgM-rheumatoid factor bound to the CH3 domain of the Fc fragment (1ADQ-PDB identification) as the initial structures for theoretical studies of dye-induced changes. Commercial IgM-type rheumatoid factor (human) and sheep red blood cells with coupled IgG (human) were used for experimental tests aimed to reveal the dye-enhancement effect in this system. The specificity of antigen-antibody interaction enhanced by dye binding was studied using rabbit anti-sheep red cell antibodies to agglutinate red cells of different species. Red blood cells of hoofed mammals (horse, goat) showed weak enhancement of agglutination in the presence of Congo red. Neither agglutination nor enhancement were observed in the case of human red cells. The dye-enhancement capability in the SRBC-antiSRBC system was lost after pepsin-digestion of antibodies producing (Fab)2 fragments still agglutinating red cells. Monoclonal (myeloma) IgG, L lambda chain and ovoalbumin failed to agglutinate red cells, as expected, and showed no enhancement effect. This indicates that the enhancement effect is specific.

  5. Ergonomic evaluation of slide boards used by home care aides to assist client transfers.

    PubMed

    Sun, Chuan; Buchholz, Bryan; Quinn, Margaret; Punnett, Laura; Galligan, Catherine; Gore, Rebecca

    2018-07-01

    Home care aides risk musculoskeletal injury because they lift and move clients; the body weight of most adults exceeds the NIOSH recommended limit for lifting. Methods to reduce manual patient lifting in institutional settings are often technically or economically infeasible in home care. Our goal was to identify suitable, safe, low-technology transfer devices for home care use. Sixteen experienced home care aides performed client transfers from wheelchair to bed (upward) and bed to wheelchair (downward) in a simulated home care environment (laboratory), using four different slide boards and by hand without a device. Aides' hand forces were measured during client transfers; aides also evaluated usability of each board. Hand forces exerted while using slide boards were mostly lower than in manual transfer, and forces were lower in downward versus upward transfers. Aides judged a board with a sliding mechanism easier to use than boards without a sliding mechanism. Practitioner Summary: This paper provides quantitative biomechanical measurements showing that slide boards reduced the hand forces needed by home care aides to transfer clients from bed to wheel chair and vice versa, compared to manual lifting. Using a semi-quantitative usability survey, aides identified boards with a sliding mechanism easiest to use.

  6. Numerical analysis of the transportation characteristics of a self-running sliding stage based on near-field acoustic levitation.

    PubMed

    Feng, Kai; Liu, Yuanyuan; Cheng, Miaomiao

    2015-12-01

    Owing to its distinct non-contact and oil-free characteristics, a self-running sliding stage based on near-field acoustic levitation can be used in an environment, which demands clean rooms and zero noise. This paper presents a numerical analysis on the lifting and transportation capacity of a non-contact transportation system. Two simplified structure models, namely, free vibration and force vibration models, are proposed for the study of the displacement amplitude distribution of two cases using the finite element method. After coupling the stage displacement into the film thickness, the Reynolds equation is solved by the finite difference method to obtain the lifting and thrusting forces. Parametric analyses of the effects of amplitude, frequency, and standing wave ratio (SWR) on the sliding stage dynamic performance are investigated. Numerical results show good agreement with published experimental values. The predictions also reveal that greater transportation capacity of the self-running sliding stage is generally achieved at less SWR and at higher amplitude.

  7. Sliding Mode Control of Fractional-Order Delayed Memristive Chaotic System with Uncertainty and Disturbance

    NASA Astrophysics Data System (ADS)

    Ding, Da-Wei; Liu, Fang-Fang; Chen, Hui; Wang, Nian; Liang, Dong

    2017-12-01

    In this paper, a simplest fractional-order delayed memristive chaotic system is proposed in order to control the chaos behaviors via sliding mode control strategy. Firstly, we design a sliding mode control strategy for the fractional-order system with time delay to make the states of the system asymptotically stable. Then, we obtain theoretical analysis results of the control method using Lyapunov stability theorem which guarantees the asymptotic stability of the non-commensurate order and commensurate order system with and without uncertainty and an external disturbance. Finally, numerical simulations are given to verify that the proposed sliding mode control method can eliminate chaos and stabilize the fractional-order delayed memristive system in a finite time. Supported by the National Nature Science Foundation of China under Grant No. 61201227, Funding of China Scholarship Council, the Natural Science Foundation of Anhui Province under Grant No. 1208085M F93, 211 Innovation Team of Anhui University under Grant Nos. KJTD007A and KJTD001B

  8. Generalized Chirp Scaling Combined with Baseband Azimuth Scaling Algorithm for Large Bandwidth Sliding Spotlight SAR Imaging

    PubMed Central

    Yi, Tianzhu; He, Zhihua; He, Feng; Dong, Zhen; Wu, Manqing

    2017-01-01

    This paper presents an efficient and precise imaging algorithm for the large bandwidth sliding spotlight synthetic aperture radar (SAR). The existing sub-aperture processing method based on the baseband azimuth scaling (BAS) algorithm cannot cope with the high order phase coupling along the range and azimuth dimensions. This coupling problem causes defocusing along the range and azimuth dimensions. This paper proposes a generalized chirp scaling (GCS)-BAS processing algorithm, which is based on the GCS algorithm. It successfully mitigates the deep focus along the range dimension of a sub-aperture of the large bandwidth sliding spotlight SAR, as well as high order phase coupling along the range and azimuth dimensions. Additionally, the azimuth focusing can be achieved by this azimuth scaling method. Simulation results demonstrate the ability of the GCS-BAS algorithm to process the large bandwidth sliding spotlight SAR data. It is proven that great improvements of the focus depth and imaging accuracy are obtained via the GCS-BAS algorithm. PMID:28555057

  9. Studies with Laser Cooled Atoms and Single Molecules

    DTIC Science & Technology

    2007-09-01

    between soda lime glass slides. The bond-setting time can be tailored to allow time for precision optical alignment. We also extended our previous single...This method achieves 100% successful bonding rates between soda lime glass slides. The bond-setting time and be can tailored to allow time for...simple method to bond optical components using silica nanoparticle sol-gel chemistry. The silica nanoparticles polymerize into highly branched

  10. An Analysis of Transmission and Storage Gains from Sliding Checksum Methods

    DTIC Science & Technology

    1998-11-01

    analysed a protocol "rsync" for synchronising related files at different ends of a communications channel with a minimum of transmitted data. This report...Sliding Checksum Methods Executive Summary In a previous report we described, modelled and analysed a protocol "rsync" for synchronising related...collaborative writing of documentation and synchronisation of distributed databases in the situation where no one location is aware of the differences

  11. Rapid detection of methicillin resistance in coagulase-negative staphylococci by a penicillin-binding protein 2a-specific latex agglutination test.

    PubMed

    Horstkotte, M A; Knobloch, J K; Rohde, H; Mack, D

    2001-10-01

    The detection of PBP 2a by the MRSA-Screen latex agglutination test with 201 clinical coagulase-negative staphylococci had an initial sensitivity of 98% and a high degree of specificity for Staphylococcus epidermidis strains compared to PCR for mecA. Determination of oxacillin MICs evaluated according to the new breakpoint (0.5 microg/ml) of the National Committee for Clinical Laboratory Standards exhibited an extremely low specificity for this population.

  12. A sperm-agglutinating lectin from seeds of Jack fruit (Artocarpus heterophyllus).

    PubMed

    Namjuntra, P; Muanwongyathi, P; Chulavatnatol, M

    1985-04-30

    A lectin specific for N-acetylgalactosamine was isolated from seed extract of Jack fruit (Artocarpus heterophyllus) by ammonium sulfate precipitation, followed by affinity chromatography on a Affigel-galactosamine-agarose column. The lectin possessed agglutinating activities for human and rat sperm as well as human red blood cells. It was found to have Mr = 62,000 consisting of two dissimilar subunits of Mr = 18,000 and 13,000. It also cross-reacted with an antibody against the lectin of Osage Orange (Maclura pomifera).

  13. A novel method for preparing histology slides to integrate the teaching of gross and microscopic anatomy.

    PubMed

    Provo-Klimek, Judy A; Troyer, Deryl L

    2002-01-01

    The authors have previously reported the development of a novel technique for sampling and preparing tissue slides for routine microscopic examination, without the use of a microtome. Termed "RAMP" (Rapid Adhesive Mediated Procedure), this simple, albeit somewhat crude, technique holds promise as a method that can be used in the field by veterinary practitioners for rapid microscopic evaluations to obtain early preliminary estimates of the nature of a mass or lesion. We incorporated the use of this method into a gross anatomy course in an attempt to gauge its utility for novices in tissue sampling and histology slide preparation. By having each group of students take a tissue sample from their cadaver, the activity simulated an actual necropsy situation in which practitioners in the field might use the technique. Because students were able to follow their specimen from sampling to microscopic examination, the activity provided a valuable integration of their learning of gross and microscopic anatomy. We conducted an evaluation of the process and the resulting slides with two successive classes of students. We conclude that the RAMP method is reasonably successful in the hands of individuals not trained in tissue preparation; was well received by the students as a valuable learning tool; and could potentially yield useful histological information for practicing veterinarians. Limitations of the method are also discussed.

  14. The Stability Analysis Method of the Cohesive Granular Slope on the Basis of Graph Theory.

    PubMed

    Guan, Yanpeng; Liu, Xiaoli; Wang, Enzhi; Wang, Sijing

    2017-02-27

    This paper attempted to provide a method to calculate progressive failure of the cohesivefrictional granular geomaterial and the spatial distribution of the stability of the cohesive granular slope. The methodology can be divided into two parts: the characterization method of macro-contact and the analysis of the slope stability. Based on the graph theory, the vertexes, the edges and the edge sequences are abstracted out to characterize the voids, the particle contact and the macro-contact, respectively, bridging the gap between the mesoscopic and macro scales of granular materials. This paper adopts this characterization method to extract a graph from a granular slope and characterize the macro sliding surface, then the weighted graph is analyzed to calculate the slope safety factor. Each edge has three weights representing the sliding moment, the anti-sliding moment and the braking index of contact-bond, respectively, . The safety factor of the slope is calculated by presupposing a certain number of sliding routes and reducing Weight repeatedly and counting the mesoscopic failure of the edge. It is a kind of slope analysis method from mesoscopic perspective so it can present more detail of the mesoscopic property of the granular slope. In the respect of macro scale, the spatial distribution of the stability of the granular slope is in agreement with the theoretical solution.

  15. Microfluidic extraction and microarray detection of biomarkers from cancer tissue slides

    NASA Astrophysics Data System (ADS)

    Nguyen, H. T.; Dupont, L. N.; Jean, A. M.; Géhin, T.; Chevolot, Y.; Laurenceau, E.; Gijs, M. A. M.

    2018-03-01

    We report here a new microfluidic method allowing for the quantification of human epidermal growth factor receptor 2 (HER2) expression levels from formalin-fixed breast cancer tissues. After partial extraction of proteins from the tissue slide, the extract is routed to an antibody (Ab) microarray for HER2 titration by fluorescence. Then the HER2-expressing cell area is evaluated by immunofluorescence (IF) staining of the tissue slide and used to normalize the fluorescent HER2 signal measured from the Ab microarray. The number of HER2 gene copies measured by fluorescence in situ hybridization (FISH) on an adjacent tissue slide is concordant with the normalized HER2 expression signal. This work is the first study implementing biomarker extraction and detection from cancer tissue slides using microfluidics in combination with a microarray system, paving the way for further developments towards multiplex and precise quantification of cancer biomarkers.

  16. Finite-time control for nonlinear spacecraft attitude based on terminal sliding mode technique.

    PubMed

    Song, Zhankui; Li, Hongxing; Sun, Kaibiao

    2014-01-01

    In this paper, a fast terminal sliding mode control (FTSMC) scheme with double closed loops is proposed for the spacecraft attitude control. The FTSMC laws are included both in an inner control loop and an outer control loop. Firstly, a fast terminal sliding surface (FTSS) is constructed, which can drive the inner loop tracking-error and the outer loop tracking-error on the FTSS to converge to zero in finite time. Secondly, FTSMC strategy is designed by using Lyaponov's method for ensuring the occurrence of the sliding motion in finite time, which can hold the character of fast transient response and improve the tracking accuracy. It is proved that FTSMC can guarantee the convergence of tracking-error in both approaching and sliding mode surface. Finally, simulation results demonstrate the effectiveness of the proposed control scheme. © 2013 ISA. Published by Elsevier Ltd. All rights reserved.

  17. Rapid and Facile Microwave-Assisted Surface Chemistry for Functionalized Microarray Slides

    PubMed Central

    Lee, Jeong Heon; Hyun, Hoon; Cross, Conor J.; Henary, Maged; Nasr, Khaled A.; Oketokoun, Rafiou; Choi, Hak Soo; Frangioni, John V.

    2011-01-01

    We describe a rapid and facile method for surface functionalization and ligand patterning of glass slides based on microwave-assisted synthesis and a microarraying robot. Our optimized reaction enables surface modification 42-times faster than conventional techniques and includes a carboxylated self-assembled monolayer, polyethylene glycol linkers of varying length, and stable amide bonds to small molecule, peptide, or protein ligands to be screened for binding to living cells. We also describe customized slide racks that permit functionalization of 100 slides at a time to produce a cost-efficient, highly reproducible batch process. Ligand spots can be positioned on the glass slides precisely using a microarraying robot, and spot size adjusted for any desired application. Using this system, we demonstrate live cell binding to a variety of ligands and optimize PEG linker length. Taken together, the technology we describe should enable high-throughput screening of disease-specific ligands that bind to living cells. PMID:23467787

  18. Deformation and stabilisation mechanisms of slow rock slides in crystalline bedrock

    NASA Astrophysics Data System (ADS)

    Zangerl, C.; Prager, C.

    2009-04-01

    Deep-seated rock slides are slope instabilities which are characterised by deformation along one or several shear zones where most of the measured total slope displacement localizes. Generally, a high danger potential is given when rock slides fail in a rapid manner characterised by very high sliding velocities and/or when they develop into long run-out rock avalanches. However several field surveys and deformation monitoring data show that numerous deep-seated rock slides do not fail in a high velocity regime. In fact, many slides creep downwards at rates of some centimetres per year or even less and do not show any evidence for non-reversible acceleration in the past or in the future. Furthermore some of these slope instabilities are actually inactive (dormant) or have even reached a stabilised final state. Deformation monitoring on active rock slides show that acceleration phases characterised by velocities up to meters per day can occur. The trigger for these phases can be manifold and include heavy rainfall, snow melt, water level fluctuations of reservoirs at the slope foot, changes in the slope's equilibrium state due to antecedent slow creeping processes, changes in the material behaviour within the sliding zone, erosion along the foot of the slope, etc. Whereas the role of these triggers in promoting phases of acceleration are generally understood, the same can not be said regarding the kinematics and dynamic processes/mechanisms by which rock slide masses re-stabilise once the trigger impetus has been removed. In the context of this study the term "stabilisation" is used for rock slides which decelerate from high velocities to slow base activities or even stop moving after a certain amount of displacement. Given that reliable rock slide forecasts require the fundamental understanding of possible slope stabilisation mechanisms this study focuses on field-based and numerically obtained key-properties which influence the long-term slope deformation behaviour. On a regional scale several valleys located in amphibolites, ortho- and paragneisses of the Ötztal-Stubai crystalline basement (i.e. Kaunertal, Pitztal, Ötztal, Lüsenstal, all located in North Tyrol, Austria) were investigated. Therefore geological and morphological basis data were compiled and re-evaluated, remote sensing methods (i.e. airborne laser scanning terrain models and orthofotos) applied and field mapping campaigns performed. On a local scale several rock slides were investigated and analysed in high detail with regard to their lithological and structural inventory, geometry of sliding masses and -zones, failure mechanisms, kinematics and temporal deformation characteristics. Field data clearly show that competent rock masses, e.g. orthogneisses and amphibolites, are affected by rapid failure events and therefore are characterised by "brittle" rock mass behaviour. In contrast, the majority of the slowly moving and "self-stabilising" rock slides are located totally or partly in mica-rich incompetent crystalline rock masses, e.g. paragneisses and micaschists, and are characterised by moderately dipping sliding zones. Apart from a causal lithological influence, numerous field observations demonstrate a major influence of pre-existing geological structures on the formation and deformation behaviour of these rock slides. The nature of rock slides implies that the temporal deformation behaviour is primarily dominated by two key-features of the sliding zone i.e. the mechanical properties (shear strain strengthening or weakening) and the effective in-situ stresses. The in-situ stresses along a sliding zone are influenced by the geometry of both the sliding mass and sliding zone, the internal deformation of the sliding mass and the pore pressures. All these properties can vary during progressive shear displacements. Especially large shear displacements in the range of tens to hundreds of metres along a distinct sliding zone can cause significant in-situ stress changes which in turn may influence the slope deformation behaviour and stabilisation mechanisms. In order to study these processes for selected case studies in paragneissic rock masses the impact of the sliding mass geometry and sliding zone shape on the in-situ stresses has been investigated by applying the discrete element method. This numerical approach enables the simulation of large shear displacements and complex block assembly interactions. Results show that slope stabilisation can be achieved when the dip angle of the sliding zone flattens downslope. In this case and after a certain amount of displacement the lower part of the rock slide mass reaches stable slope conditions (shear strength of the sliding zone material exceeds the shear stress acting on the sliding zone) and acts as a resisting mass for the still unstable upper part of the slope. Furthermore numerical models show that secondary slides at the lower part of the slope have a similar effect. In both case cases the observed slope stabilisation can be clearly attributed to the formation of natural buttressing masses at the toe.

  19. A comparative study to evaluate the effects of ligation methods on friction in sliding mechanics using 0.022" slot brackets in dry state: An In-vitro study.

    PubMed

    Vinay, K; Venkatesh, M J; Nayak, Rabindra S; Pasha, Azam; Rajesh, M; Kumar, Pradeep

    2014-04-01

    Friction between archwires and brackets is assuming greater importance for finishing with increased use of sliding mechanics in orthodontics as friction impedes the desired tooth movement. The following study is conducted to compare and evaluate the effect of ligation on friction in sliding mechanics using 0.022" slot bracket in dry condition. In the study 48 combinations of brackets, archwires and different ligation techniques were tested in order to provide best combination that offers less friction during sliding mechanics. Instron- 4467 machine was used to evaluate static and kinetic friction force values and the results were subjected to Statistical Analysis and Anova test. The results of the study showed that 0.022" metal brackets, Stainless steel wires and Slick modules provided the optimum frictional resistance to sliding mechanics. It is observed that frictional forces of 0.019" x 0.025" were higher when compared with 0.016" x 0.022" Stainless steel archwire due to the increase in dimension. Self-ligating brackets offered least friction followed by mini twin, variable force, regular stainless steel, ceramic with metal insert bracket and ceramic brackets. The stainless steel ligature offered less resistance than slick and grey modules, and TMA wires recorded maximum friction. The stainless steel archwire of 0.019" x 0.025" dimension are preferred during sliding mechanics, these archwires with variable force brackets ligated with Slick Modules offer decreased friction and is cost effective combination which can be utilized during sliding mechanics. How to cite the article: Vinay K, Venkatesh MJ, Nayak RS, Pasha A, Rajesh M, Kumar P. A comparative study to evaluate the effects of ligation methods on friction in sliding mechanics using 0.022" slot brackets in dry state: An In-vitro study. J Int Oral Health 2014;6(2):76-83.

  20. Current Sensor Fault Diagnosis Based on a Sliding Mode Observer for PMSM Driven Systems

    PubMed Central

    Huang, Gang; Luo, Yi-Ping; Zhang, Chang-Fan; Huang, Yi-Shan; Zhao, Kai-Hui

    2015-01-01

    This paper proposes a current sensor fault detection method based on a sliding mode observer for the torque closed-loop control system of interior permanent magnet synchronous motors. First, a sliding mode observer based on the extended flux linkage is built to simplify the motor model, which effectively eliminates the phenomenon of salient poles and the dependence on the direct axis inductance parameter, and can also be used for real-time calculation of feedback torque. Then a sliding mode current observer is constructed in αβ coordinates to generate the fault residuals of the phase current sensors. The method can accurately identify abrupt gain faults and slow-variation offset faults in real time in faulty sensors, and the generated residuals of the designed fault detection system are not affected by the unknown input, the structure of the observer, and the theoretical derivation and the stability proof process are concise and simple. The RT-LAB real-time simulation is used to build a simulation model of the hardware in the loop. The simulation and experimental results demonstrate the feasibility and effectiveness of the proposed method. PMID:25970258

  1. Field-programmable analogue arrays for the sensorless control of DC motors

    NASA Astrophysics Data System (ADS)

    Rivera, J.; Dueñas, I.; Ortega, S.; Del Valle, J. L.

    2018-02-01

    This work presents the analogue implementation of a sensorless controller for direct current motors based on the super-twisting (ST) sliding mode technique, by means of field programmable analogue arrays (FPAA). The novelty of this work is twofold, first is the use of the ST algorithm in a sensorless scheme for DC motors, and the implementation method of this type of sliding mode controllers in FPAAs. The ST algorithm reduces the chattering problem produced with the deliberate use of the sign function in classical sliding mode approaches. On the other hand, the advantages of the implementation method over a digital one are that the controller is not digitally approximated, the controller gains are not fine tuned and the implementation does not require the use of analogue-to-digital and digital-to-analogue converter circuits. In addition to this, the FPAA is a reconfigurable, lower cost and power consumption technology. Simulation and experimentation results were registered, where a more accurate transient response and lower power consumption were obtained by the proposed implementation method when compared to a digital implementation. Also, a more accurate performance by the DC motor is obtained with proposed sensorless ST technique when compared with a classical sliding mode approach.

  2. Clinico-serologic co-relation in bi-directional ABO incompatible hemopoietic stem cell transplantation.

    PubMed

    Basu, Sabita; Dhar, Supriya; Mishra, Deepak; Chandy, Mammen

    2015-01-01

    The ABO blood group system is of prime significance in red cell transfusion and organ transplantation. However, ABO compatibility is not critical in allogenic hemopoietic stem cell transplantation (HSCT) and approximately 40-50% of hemopoietic stem cell transplants are ABO incompatible. This incompatibility may be major, minor or bi-directional. Though there are descriptions of transfusion practice and protocols in ABO incompatible HSCT, there are considerable variations and transfusion support in these patients can be very challenging. The immunohematologic observations in two cases of bi-directional ABO incompatible HSCT have been described, and clinico-serologic correlation has been attempted. In both cases, peripheral blood stem cell harvests were obtained using the Cobe spectra cell separator. Immunohematologic assessments in the donor and recipient were done as a part of pre HSCT evaluation. Both the standard tube technique and column agglutination method (Ortho Biovue Micro Bead System) was used. Antibody screen was done by column agglutination method using three cell panel (Surgiscreen cells). Isoagglutinin titration was done by the master dilution method and standard validated techniques were used. The pattern of laboratory findings in the two cases was different and so were the clinical outcomes. Although there was early engraftment in the first case, the second case developed pure red cell aplasia and this was well-reflected in the immunohematologic assessments. Immunohematologic assessment correlated well with the clinical picture and could be used to predict clinical outcome and onset of complications in ABO incompatible HSCT.

  3. Methodology for the Assessment of 3D Conduction Effects in an Aerothermal Wind Tunnel Test

    NASA Technical Reports Server (NTRS)

    Oliver, Anthony Brandon

    2010-01-01

    This slide presentation reviews a method for the assessment of three-dimensional conduction effects during test in a Aerothermal Wind Tunnel. The test objectives were to duplicate and extend tests that were performed during the 1960's on thermal conduction on proturberance on a flat plate. Slides review the 1D versus 3D conduction data reduction error, the analysis process, CFD-based analysis, loose coupling method that simulates a wind tunnel test run, verification of the CFD solution, Grid convergence, Mach number trend, size trends, and a Sumary of the CFD conduction analysis. Other slides show comparisons to pretest CFD at Mach 1.5 and 2.16 and the geometries of the models and grids.

  4. Dynamic boundary layer based neural network quasi-sliding mode control for soft touching down on asteroid

    NASA Astrophysics Data System (ADS)

    Liu, Xiaosong; Shan, Zebiao; Li, Yuanchun

    2017-04-01

    Pinpoint landing is a critical step in some asteroid exploring missions. This paper is concerned with the descent trajectory control for soft touching down on a small irregularly-shaped asteroid. A dynamic boundary layer based neural network quasi-sliding mode control law is proposed to track a desired descending path. The asteroid's gravitational acceleration acting on the spacecraft is described by the polyhedron method. Considering the presence of input constraint and unmodeled acceleration, the dynamic equation of relative motion is presented first. The desired descending path is planned using cubic polynomial method, and a collision detection algorithm is designed. To perform trajectory tracking, a neural network sliding mode control law is given first, where the sliding mode control is used to ensure the convergence of system states. Two radial basis function neural networks (RBFNNs) are respectively used as an approximator for the unmodeled term and a compensator for the difference between the actual control input with magnitude constraint and nominal control. To improve the chattering induced by the traditional sliding mode control and guarantee the reachability of the system, a specific saturation function with dynamic boundary layer is proposed to replace the sign function in the preceding control law. Through the Lyapunov approach, the reachability condition of the control system is given. The improved control law can guarantee the system state move within a gradually shrinking quasi-sliding mode band. Numerical simulation results demonstrate the effectiveness of the proposed control strategy.

  5. Validation of the Sysmex sp-1000i automated slide preparer-stainer in a clinical laboratory

    PubMed Central

    de Bitencourt, Eberson Damião dos Santos; Voegeli, Carlos Franco; Onzi, Gabriela dos Santos; Boscato, Sara Cardoso; Ghem, Carine; Munhoz, Terezinha

    2013-01-01

    Background The speed and quality of information have become essential items in the release of laboratory reports. The Sysmex®SP1000-I device has been developed to prepare and stain smear slides. However, for a device to be cleared for use in the laboratory routine it must pass through a validation process. Objective To evaluate the performance and reliability of the Sysmex® SP-1000i slide preparer-stainer incorporated into the routine of a hospital laboratory in Porto Alegre. Methods Peripheral blood samples of patients attending the laboratory for ambulatory exams with leukocyte counts between 7000/°L and 12,000/°L were evaluated, independent of gender and age. Two slides were prepared for each sample using the Sysmex® SP-1000i equipment; one of the slides was used to perform quality control tests using the CellaVision® DM96 device, and the other slide was used to compare pre-classification by the same device and the classification performed by a pharmacist-biochemist. Results The results of all the slides used as controls were acceptable according to the quality control test as established by the manufacturer of the device. In the comparison between the automated pre-classification and the classification made by the professional, there was an acceptable variation in the differential counts of leukocytes for 90% of the analyzed slides. Pearson correlation coefficient showed a strong correlation for band neutrophils (r = 0.802; p-value < 0.001), segmented neutrophils (r = 0.963; p-value < 0.001), eosinophils (r = 0.958; p-value < 0.001), lymphocytes (r = 0.985; p-value < 0.001) and atypical lymphocytes (r = 0.866; p-value < 0.001) using both methods. The red blood cell analysis was adequate for all slides analyzed by the equipment and by the professional. Conclusion The new Sysmex®SP1000-i methodology was found to be reliable, fast and safe for the routines of medium and large laboratories, improving the quality of microscopic analysis in complete blood counts. PMID:24478606

  6. Failure mechanism of coated biomaterials under high impact-sliding contact stresses

    NASA Astrophysics Data System (ADS)

    Chen, Ying

    This study uses a newly developed testing method--- inclined cyclic impact-sliding test to investigate the failure behaviors of different types of biomaterials, (SS316L, Ti6Al4V and CoCr) coated by different coatings (TiN, DLC and PEO), under extremely high dynamic contact stress conditions. This test method can simulate the combined impact and sliding/rolling loading conditions, which is very practical in many aspects of commercial usages. During the tests, fatigue cracking, chipping, peeling and material transferring were observed in damaged area. This research is mainly focused on the failure behaviors of load-bearing materials which cyclic impacting and sliding are always involved. This purpose was accomplished in the three stages: First, impact-sliding test was carried out on TiN coated unhardened M2. It was found that soft substrate can cause early failure of coating due to the considerable plastic deformation in the substrate. In this case, stronger substrate is required to support coating better when tested under high contact stresses. Second, PEO coated Ti-6Al-4V was tested under pure sliding and impact-sliding wear conditions. PEO coating was found not strong enough to afford the high contact pressure under cyclic impact-sliding wear test due to its porous surface structure. However, the wear performance of PEO coating was enhanced due to the sub-stoichiometric oxide. To sum up, for load-bearing biomedical implants involved in high impacting movement, PEO coating may not be a promising surface protection. Third, the dense, smooth PVD/CVD bio-inert coatings were reconsidered. DLC and TiN coatings, combined by different substrates together with different interface materials were tested under the cyclic impact-sliding test using a set of proper loading. The results show that to choose a proper combination of coating, interface and substrate based on their mechanical properties is of great importance under the test condition. Hard substrates provide support to coating better and a ductile and adhesive interface layer can delay the cracked coating from peeled-off.

  7. A method for normalizing pathology images to improve feature extraction for quantitative pathology.

    PubMed

    Tam, Allison; Barker, Jocelyn; Rubin, Daniel

    2016-01-01

    With the advent of digital slide scanning technologies and the potential proliferation of large repositories of digital pathology images, many research studies can leverage these data for biomedical discovery and to develop clinical applications. However, quantitative analysis of digital pathology images is impeded by batch effects generated by varied staining protocols and staining conditions of pathological slides. To overcome this problem, this paper proposes a novel, fully automated stain normalization method to reduce batch effects and thus aid research in digital pathology applications. Their method, intensity centering and histogram equalization (ICHE), normalizes a diverse set of pathology images by first scaling the centroids of the intensity histograms to a common point and then applying a modified version of contrast-limited adaptive histogram equalization. Normalization was performed on two datasets of digitized hematoxylin and eosin (H&E) slides of different tissue slices from the same lung tumor, and one immunohistochemistry dataset of digitized slides created by restaining one of the H&E datasets. The ICHE method was evaluated based on image intensity values, quantitative features, and the effect on downstream applications, such as a computer aided diagnosis. For comparison, three methods from the literature were reimplemented and evaluated using the same criteria. The authors found that ICHE not only improved performance compared with un-normalized images, but in most cases showed improvement compared with previous methods for correcting batch effects in the literature. ICHE may be a useful preprocessing step a digital pathology image processing pipeline.

  8. Serotyping of Actinobacillus pleuropneumoniae serotype 5 strains using a monoclonal-based polystyrene agglutination test.

    PubMed Central

    Dubreuil, J D; Letellier, A; Stenbaek, E; Gottschalk, M

    1996-01-01

    A polystyrene agglutination test has been developed for serotyping Actinobacillus pleuropneumoniae serotype 5a and 5b strains. Protein A-coated polystyrene microparticles were sensitized with a murine monoclonal antibody recognizing an epitope on serotype 5 LPS-O chain as shown by SDS-PAGE and Western blotting. A total of 205 A. pleuropneumoniae, strains including all 12 serotype reference strains and 13 strains representing 8 common bacterial species associated with swine or related to A. pleuropneumoniae, were tested by mixing 25 microL of polystyrene reagent with the same volume of a dense suspension of bacterial cells grown for 18 h. All A. pleuropneumoniae strains had been previously serotyped using standard procedures. The polystyrene agglutination test was rapid (less than 3 min) and easy to perform. Overall a very good correlation (97.3%) with the standard techniques was found. The sensitized polystyrene particles were stable for at least 6 mo. Images Figure 1. PMID:8825998

  9. A deep-sea agglutinated foraminifer tube constructed with planktonic foraminifer shells of a single species

    NASA Astrophysics Data System (ADS)

    Pearson, Paul N.; Expedition 363 Shipboard Scientific Party, IODP

    2018-01-01

    Agglutinated foraminifera are marine protists that show apparently complex behaviour in constructing their shells, involving selecting suitable sedimentary grains from their environment, manipulating them in three dimensions, and cementing them precisely into position. Here we illustrate a striking and previously undescribed example of complex organisation in fragments of a tube-like foraminifer (questionably assigned to Rhabdammina) from 1466 m water depth on the northwest Australian margin. The tube is constructed from well-cemented siliciclastic grains which form a matrix into which hundreds of planktonic foraminifer shells are regularly spaced in apparently helical bands. These shells are of a single species, Turborotalita clarkei, which has been selected to the exclusion of all other bioclasts. The majority of shells are set horizontally in the matrix with the umbilical side upward. This mode of construction, as is the case with other agglutinated tests, seems to require either an extraordinarily selective trial-and-error process at the site of cementation or an active sensory and decision-making system within the cell.

  10. Molecular dynamic simulation of Copper and Platinum nanoparticles Poiseuille flow in a nanochannels

    NASA Astrophysics Data System (ADS)

    Toghraie, Davood; Mokhtari, Majid; Afrand, Masoud

    2016-10-01

    In this paper, simulation of Poiseuille flow within nanochannel containing Copper and Platinum particles has been performed using molecular dynamic (MD). In this simulation LAMMPS code is used to simulate three-dimensional Poiseuille flow. The atomic interaction is governed by the modified Lennard-Jones potential. To study the wall effects on the surface tension and density profile, we placed two solid walls, one at the bottom boundary and the other at the top boundary. For solid-liquid interactions, the modified Lennard-Jones potential function was used. Velocity profiles and distribution of temperature and density have been obtained, and agglutination of nanoparticles has been discussed. It has also shown that with more particles, less time is required for the particles to fuse or agglutinate. Also, we can conclude that the agglutination time in nanochannel with Copper particles is faster that in Platinum nanoparticles. Finally, it is demonstrated that using nanoparticles raises thermal conduction in the channel.

  11. [Study on the extraction technology and hypoglycemic activity of lectin from Trichosanthes kirilowi].

    PubMed

    Li, Qiong; Ye, Xiao-Li; Zeng, Hong; Chen, Xin; Li, Xue-Gang

    2012-03-01

    To extract lectins from Trichosanthes kirilowi and study their hypoglycemic activity. The optimal extraction process included the following parameters were conformed by optimization analysis,lectins extracted from Trichosanthes kirilowi was achieved by ammonium sulfate precipitation; The agglutinate activity was determined by using the agglutination test with 5% human blood cells. Human hepatocarcinoma cell HepG2 and the alloxan-induced diabetic mice model were used to assess hypoglycemic activity of Lectin in Trichosanthes kirilowi. The agglutination indexes of lectins extraction buffer were 32; The cell and mice tests indicated that the lectins exhibited hypoglycemic activity in the 70% saturation. The optimum extraction technology is as follows: extraction with PBS, the material-water ratio is 1:30, the extraction time is 24 h, while the concentration of sodium chloride is 0 mol/L and pH is 7.2. Precipitate lectins by ammonium sulfate in the 70% saturation, centrifugal speed is 10 000 tracted from Trichosanthes kirilowi exposes proper hypoglycemic activity.

  12. siRNA delivery targeting to the lung via agglutination-induced accumulation and clearance of cationic tetraamino fullerene.

    PubMed

    Minami, Kosuke; Okamoto, Koji; Doi, Kent; Harano, Koji; Noiri, Eisei; Nakamura, Eiichi

    2014-05-12

    The efficient treatment of lung diseases requires lung-selective delivery of agents to the lung. However, lung-selective delivery is difficult because the accumulation of micrometer-sized carriers in the lung often induces inflammation and embolization-related toxicity. Here we demonstrate a lung-selective delivery system of small interfering RNA (siRNA) by controlling the size of carrier vehicle in blood vessels. The carrier is made of tetra(piperazino)fullerene epoxide (TPFE), a water-soluble cationic tetraamino fullerene. TPFE and siRNA form sub-micrometer-sized complexes in buffered solution and these complexes agglutinate further with plasma proteins in the bloodstream to form micrometer-sized particles. The agglutinate rapidly clogs the lung capillaries, releases the siRNA into lung cells to silence expression of target genes, and is then cleared rapidly from the lung after siRNA delivery. We applied our delivery system to an animal model of sepsis, indicating the potential of TPFE-based siRNA delivery for clinical applications.

  13. siRNA delivery targeting to the lung via agglutination-induced accumulation and clearance of cationic tetraamino fullerene

    NASA Astrophysics Data System (ADS)

    Minami, Kosuke; Okamoto, Koji; Doi, Kent; Harano, Koji; Noiri, Eisei; Nakamura, Eiichi

    2014-05-01

    The efficient treatment of lung diseases requires lung-selective delivery of agents to the lung. However, lung-selective delivery is difficult because the accumulation of micrometer-sized carriers in the lung often induces inflammation and embolization-related toxicity. Here we demonstrate a lung-selective delivery system of small interfering RNA (siRNA) by controlling the size of carrier vehicle in blood vessels. The carrier is made of tetra(piperazino)fullerene epoxide (TPFE), a water-soluble cationic tetraamino fullerene. TPFE and siRNA form sub-micrometer-sized complexes in buffered solution and these complexes agglutinate further with plasma proteins in the bloodstream to form micrometer-sized particles. The agglutinate rapidly clogs the lung capillaries, releases the siRNA into lung cells to silence expression of target genes, and is then cleared rapidly from the lung after siRNA delivery. We applied our delivery system to an animal model of sepsis, indicating the potential of TPFE-based siRNA delivery for clinical applications.

  14. Serodiagnosis of bovine leptospirosis by IgG-enzyme-linked immunosorbent assay and latex agglutination test.

    PubMed

    Senthilkumar, T M A; Subathra, M; Ramadass, P; Ramaswamy, V

    2010-02-01

    The efficacy of a recombinant leptospiral outer membrane protein LipL41 as an antigen for conducting IgG-Enzyme linked immunosorbent assay (ELISA) and latex agglutination test (LAT) for serodiagnosis of bovine leptospirosis was evaluated. The recombinant LipL41 antigen developed and used for detecting the antibodies was specific in detection of the pathogenic serovars of Leptospira, as the expression of the LipL41 antigen is restricted only to pathogenic leptospires. A total of 430 bovine serum samples were subjected to IgG-ELISA and LAT, and the sensitivity and specificity were assessed in comparison with microscopic agglutination test (MAT). The sensitivity and specificity of IgG-ELISA and LAT were 86.84% and 93.16%, and 95.42% and 98.33% respectively. Both the tests are found to be sensitive, specific and concurred with the standard MAT. The study concluded that the rLipL41 protein could be used as a potential diagnostic antigen in different assay formats for bovine leptospirosis.

  15. Minimization of bacterial size allows for complement evasion and is overcome by the agglutinating effect of antibody

    PubMed Central

    Dalia, Ankur B.; Weiser, Jeffrey N.

    2011-01-01

    SUMMARY The complement system, which functions by lysing pathogens directly or by promoting their uptake by phagocytes, is critical for controlling many microbial infections. Here we show that in Streptococcus pneumoniae, increasing bacterial chain length sensitizes this pathogen to complement deposition and subsequent uptake by human neutrophils. Consistent with this, we show that minimizing chain length provides wild-type bacteria with a competitive advantage in vivo in a model of systemic infection. Investigating how the host overcomes this virulence strategy, we find that antibody promotes complement-dependent opsonophagocytic killing of Streptococcus pneumoniae and lysis of Haemophilus influenzae independent of Fc-mediated effector functions. Consistent with the agglutinating effect of antibody, F(ab′)2 but not Fab could promote this effect. Therefore, increasing pathogen size, whether by natural changes in cellular morphology or via antibody-mediated agglutination, promotes complement-dependent killing. These observations have broad implications for how cell size and morphology can affect virulence among pathogenic microbes. PMID:22100164

  16. siRNA delivery targeting to the lung via agglutination-induced accumulation and clearance of cationic tetraamino fullerene

    PubMed Central

    MINAMI, Kosuke; OKAMOTO, Koji; DOI, Kent; HARANO, Koji; NOIRI, Eisei; NAKAMURA, Eiichi

    2014-01-01

    The efficient treatment of lung diseases requires lung-selective delivery of agents to the lung. However, lung-selective delivery is difficult because the accumulation of micrometer-sized carriers in the lung often induces inflammation and embolization-related toxicity. Here we demonstrate a lung-selective delivery system of small interfering RNA (siRNA) by controlling the size of carrier vehicle in blood vessels. The carrier is made of tetra(piperazino)fullerene epoxide (TPFE), a water-soluble cationic tetraamino fullerene. TPFE and siRNA form sub-micrometer-sized complexes in buffered solution and these complexes agglutinate further with plasma proteins in the bloodstream to form micrometer-sized particles. The agglutinate rapidly clogs the lung capillaries, releases the siRNA into lung cells to silence expression of target genes, and is then cleared rapidly from the lung after siRNA delivery. We applied our delivery system to an animal model of sepsis, indicating the potential of TPFE-based siRNA delivery for clinical applications. PMID:24814863

  17. Automated complete slide digitization: a medium for simultaneous viewing by multiple pathologists.

    PubMed

    Leong, F J; McGee, J O

    2001-11-01

    Developments in telepathology robotic systems have evolved the concept of a 'virtual microscope' handling 'digital slides'. Slide digitization is a method of archiving salient histological features in numerical (digital) form. The value and potential of this have begun to be recognized by several international centres. Automated complete slide digitization has application at all levels of clinical practice and will benefit undergraduate, postgraduate, and continuing education. Unfortunately, as the volume of potential data on a histological slide represents a significant problem in terms of digitization, storage, and subsequent manipulation, the reality of virtual microscopy to date has comprised limited views at inadequate resolution. This paper outlines a system refined in the authors' laboratory, which employs a combination of enhanced hardware, image capture, and processing techniques designed for telepathology. The system is able to scan an entire slide at high magnification and create a library of such slides that may exist on an internet server or be distributed on removable media (such as CD-ROM or DVD). A digital slide allows image data manipulation at a level not possible with conventional light microscopy. Combinations of multiple users, multiple magnifications, annotations, and addition of ancillary textual and visual data are now possible. This demonstrates that with increased sophistication, the applications of telepathology technology need not be confined to second opinion, but can be extended on a wider front. Copyright 2001 John Wiley & Sons, Ltd.

  18. Prediction Study on Anti-Slide Control of Railway Vehicle Based on RBF Neural Networks

    NASA Astrophysics Data System (ADS)

    Yang, Lijun; Zhang, Jimin

    While railway vehicle braking, Anti-slide control system will detect operating status of each wheel-sets e.g. speed difference and deceleration etc. Once the detected value on some wheel-set is over pre-defined threshold, brake effort on such wheel-set will be adjusted automatically to avoid blocking. Such method takes effect on guarantee safety operation of vehicle and avoid wheel-set flatness, however it cannot adapt itself to the rail adhesion variation. While wheel-sets slide, the operating status is chaotic time series with certain law, and can be predicted with the law and experiment data in certain time. The predicted values can be used as the input reference signals of vehicle anti-slide control system, to judge and control the slide status of wheel-sets. In this article, the RBF neural networks is taken to predict wheel-set slide status in multi-step with weight vector adjusted based on online self-adaptive algorithm, and the center & normalizing parameters of active function of the hidden unit of RBF neural networks' hidden layer computed with K-means clustering algorithm. With multi-step prediction simulation, the predicted signal with appropriate precision can be used by anti-slide system to trace actively and adjust wheel-set slide tendency, so as to adapt to wheel-rail adhesion variation and reduce the risk of wheel-set blocking.

  19. Influence of Forming Conditions on Springback in V-bending Process Using Servo Press

    NASA Astrophysics Data System (ADS)

    Abe, Shinya; Takahashi, Susumu

    To improve fuel efficiency, aluminum alloys and high tensile steel sheets are increasingly being applied to automotive body parts. However, it is difficult to obtain accurate dimensions of formed parts. Therefore, technologies for reducing springback for the part formed by press are strongly demanded. It is said that the die holding time at the bottom dead center of a servo press slide can affect springback. To clarify the forming mechanisms of this phenomenon, a V bending test with a servo press was performed. Aluminum alloys sheets are applied as specimens. The location of press slide was measured by linear scales. It was found that the movement of the slide in a slide motion program differs from the actual movement of the slide. It is important to confirm if the slide is located in the position specified in the program. In addition, a springback angle measurement system is proposed that uses laser displacement measurement apparatus. Because it avoids human error, the proposed measurement system is more accurate than the image processing method.

  20. SWCD: a sliding window and self-regulated learning-based background updating method for change detection in videos

    NASA Astrophysics Data System (ADS)

    Işık, Şahin; Özkan, Kemal; Günal, Serkan; Gerek, Ömer Nezih

    2018-03-01

    Change detection with background subtraction process remains to be an unresolved issue and attracts research interest due to challenges encountered on static and dynamic scenes. The key challenge is about how to update dynamically changing backgrounds from frames with an adaptive and self-regulated feedback mechanism. In order to achieve this, we present an effective change detection algorithm for pixelwise changes. A sliding window approach combined with dynamic control of update parameters is introduced for updating background frames, which we called sliding window-based change detection. Comprehensive experiments on related test videos show that the integrated algorithm yields good objective and subjective performance by overcoming illumination variations, camera jitters, and intermittent object motions. It is argued that the obtained method makes a fair alternative in most types of foreground extraction scenarios; unlike case-specific methods, which normally fail for their nonconsidered scenarios.

  1. Determination of immune status in dogs against CPV-2 by recombinant protein based latex agglutination test.

    PubMed

    Thomas, Jobin; Singh, Mithilesh; Goswami, T K; Glora, Philma; Chakravarti, Soumendu; Chander, Vishal; Upmanyu, Vikramaditya; Verma, Suman; Sharma, Chhavi; Mahendran, K

    2017-09-01

    Canine parvoviral enteritis is a highly contagious viral illness caused by canine parvovirus-2 (CPV-2) which affects puppies of mainly 6-20 weeks of age. Vaccination is pivotal in preventing and controlling CPV-2 infection. Determination of antibody status is a critical determinant for successful vaccination. The hemagglutination inhibition (HI) test is 'gold standard' test for quantification of antibodies specific to CPV-2, although the execution of this test is not feasible under field conditions. The present study was undertaken to develop a point of care testing to determine immune status prior to CPV-2 vaccination or to detect seroconversion in immunized dogs by latex agglutination test (LAT) using recombinant antigen. Truncated portion of VP2 protein (tVP2) of CPV-2 was selected on the basis of antigenic indices, overexpressed the recombinant protein in E. coli system and was subsequently used in development of LAT. A total of 59 serum samples obtained from vaccinated (n = 54) and healthy unvaccinated (n = 5) dogs were tested. The positivity was observed in 85% (46/54) of these dogs with varying agglutination pattern. The overall sensitivity and specificity of latex agglutination test in comparison to HI test was recorded as 90% and 88% respectively with an agreement value of 90% (CI = 95%). Copyright © 2017 International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.

  2. Altered expression of blood group A and H antigens on red cells from an acute leukemic patient.

    PubMed

    Matsuki, T; Shimano, S; Furukawa, K

    1992-01-01

    Alternate expressions of the blood group A and H antigens on red cells are described in a patient with acute myelocytic leukemia. The patient's red cells showed mixed field agglutination with anti-A and anti-H sera and lectins, and no agglutination with anti-B serum. The agglutinability of the A red cells with Dolichos biflorus lectin was between A1 and A2 (A intermediate). Inagglutinable red cells were separated with anti-A agglutinin, and the proportion was about 80% of total cells. The agglutinating activity with Ulex europaeus anti-H of red cells, which were inagglutinable with anti-A, was 16 times weaker than that of group O cells. The weaker reaction with Ricinus communis lectin and the stronger reaction with Psathyrella velutina lectin on the inagglutinable cells with anti-A than those on the group O cells suggest that fucosyl alpha (1-2) and galactosyl beta (1-4) residues at the nonreducing end of carbohydrate chains of H antigens on the red cells were diminished, and N-acetylglucosaminyl beta (1-3) residues were sequentially exposed. His saliva contained A and H substances in normal amounts of a secretor. Serum alpha-N-acetylgalactosaminyltransferase activity which converts O red cells to A red cells was the same as those in sera from A1 individuals. These results suggest that the synthesis of H precursors is partially blocked in this patient's red cells.

  3. Seroepidemiology of leptospirosis in livestock in Trinidad.

    PubMed

    Suepaul, Sharianne M; Carrington, Christine V; Campbell, Mervyn; Borde, Gustave; Adesiyun, Abiodun Adewale

    2011-02-01

    A study was conducted to determine the seroprevalence of leptospirosis and infecting serovars across livestock (cattle, sheep, goats, and pigs) in Trinidad using the microscopic agglutination test with an international panel of 23 serovars. Of a total of 590 cattle tested, 21.5% were seropositive with agglutinations to 13 of the 23 antigens used in the panel. Icterohaemorrhagiae (9.3%), Sejroe (4.1%), Ballum (4.1%), and Autumnalis (1.9%) were the predominant serogroups detected in the cattle sampled (n = 590). Of 222 sheep tested, 5.0% were seropositive with agglutinations to five serovars belonging to two serogroups. These serogroups were Autumnalis at 2.7%, and Icterohaemorrhagiae at 2.3% of all sheep tested (n = 222). Of a total of 180 goats tested, 3.3% were seropositive, all agglutinating to the Icterohaemorrhagiae serogroup, 1.7% to serovar Copenhageni, 1.1% to serovar Mankarso, and 0.6% to serovar Icterohaemorrhagiae. Among pigs (n = 200), 5.0% were seropositive for five serovars belonging to three serogroups. These serogroups were Icterohaemorrhagiae at 2.5%, Australis at 2%, and Ballum at 0.5%. Overall, age and sex of animals were not significantly associated with leptospirosis with the exception of cattle where age was a significant factor for seropositivity. It was concluded that for livestock, leptospirosis may be an important zoonotic and economic disease, particularly in the case of cattle. It is imperative that the impact of leptospirosis on abortion, stillbirths, and decreased milk production in livestock in the country be assessed.

  4. Agglutinating mouse IgG3 compares favourably with IgMs in typing of the blood group B antigen: Functionality and stability studies

    PubMed Central

    Klaus, Tomasz; Bzowska, Monika; Kulesza, Małgorzata; Kabat, Agnieszka Martyna; Jemioła-Rzemińska, Małgorzata; Czaplicki, Dominik; Makuch, Krzysztof; Jucha, Jarosław; Karabasz, Alicja; Bereta, Joanna

    2016-01-01

    Mouse immunoglobulins M (IgMs) that recognize human blood group antigens induce haemagglutination and are used worldwide for diagnostic blood typing. Contrary to the current belief that IgGs are too small to simultaneously bind antigens on two different erythrocytes, we obtained agglutinating mouse IgG3 that recognized antigen B of the human ABO blood group system. Mouse IgG3 is an intriguing isotype that has the ability to form Fc-dependent oligomers. However, F(ab′)2 fragments of the IgG3 were sufficient to agglutinate type B red blood cells; therefore, IgG3-triggered agglutination did not require oligomerization. Molecular modelling indicated that mouse IgG3 has a larger range of Fab arms than other mouse IgG subclasses and that the unique properties of mouse IgG3 are likely due to the structure of its hinge region. With a focus on applications in diagnostics, we compared the stability of IgG3 and two IgMs in formulated blood typing reagents using an accelerated storage approach and differential scanning calorimetry. IgG3 was much more stable than IgMs. Interestingly, the rapid decrease in IgM activity was caused by aggregation of the molecules and a previously unknown posttranslational proteolytic processing of the μ heavy chain. Our data point to mouse IgG3 as a potent diagnostic tool. PMID:27484487

  5. [Yes, we should keep ABO agglutination test within bedside transfusion checks].

    PubMed

    Daurat, G

    2008-11-01

    ABO incompatible transfusions are still a frequent cause of serious adverse transfusion reactions. Bedside check is intended to detect patient errors and prevent ABO mismatch. France is one of the few countries that includes ABO agglutination test for red blood cells in bedside checks. Evaluation of this ABO agglutination test, performed with a special card, shows that, on the field, despite frequent users' mishandling, it can detect up to 93% of ABO incompatibilities. This is not enough to rely on this sole test for bedside checks. But, linking it with an another test, currently, checks that the right blood is given to the right patient, rises the sensitivity of the whole bedside procedure up to an estimated 99.65%, for detection of ABO incompatibilities. This linkage has been introduced in the French regulation in 2003. Since then, the incidence of ABO incompatible transfusions has decreased dramatically and faster than in any other country, so France has now, probably, the lowest rate of ABO incompatible transfusions. The investigation of the few ABO accidents that still occur, shows that professionals have always bypassed this linkage. On the other hand, introducing bedside recipient and blood products barcode or radio-chip checks in all the 1500 French hospitals, though technically possible, would provide very little enhancement and lead to major difficulties and expenses. Linkage of ABO agglutination test to patient and blood checks within the bedside procedure has proved to be efficient and should be kept.

  6. Latex agglutination using the periplasmic proteins antigen of Brucella melitensis is a successful, rapid, and specific serodiagnostic test for ovine brucellosis

    PubMed Central

    Ismael, Alaa Bassuny; Swelum, Ayman Abdel-Aziz; Mostafa, Salama A-H; Alhumiany, Abdel-Rahman A

    2016-01-01

    Brucellosis, especially caused by Brucella melitensis, is considered the most-widespread zoonosis in the world, particularly in developing countries. This study was planned to develop an accurate test for diagnosis of ovine brucellosis using a specific hot saline extracted soluble Brucella melitensis periplasmic proteins (SBPPs). The efficacy of the latex agglutination test (LAT) using SBPPs compared to the Rose Bengal test (RBT), buffered plate agglutination test (BPAT), serum agglutination test (SAT), and an indirect enzyme-linked immunosorbent assay (i-ELISA) was evaluated in the field diagnosis of ovine brucellosis. The test performance was evaluated by estimating sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), disease prevalence (DP), positive likelihood ratio (PLR), and negative likelihood ratio (NLR) using test agreement and bacteriological culture in 1777 samples. The false-positive result was significantly (P ⩽0.05) lower in LAT than RBT, BPAT, SAT, and i-ELISA. With reference to test agreement, the Se, Sp, PPV, and PLR were highest (P ⩽0.05) in LAT 99.33%, 99.88%, 98.68%, and 827.25%, respectively. With reference to bacteriological culture, the LAT and i-ELISA tests showed a significant difference in Se with SAT. However, no significant difference in specificity was detected. The DP was 8.44% in the five tests. In conclusion, LAT using SBPPs of B. melitensis could be a suitable serodiagnostic field test for ovine brucellosis, with high sensitivity and specificity. PMID:27207442

  7. Latex agglutination using the periplasmic proteins antigen of Brucella melitensis is a successful, rapid, and specific serodiagnostic test for ovine brucellosis.

    PubMed

    Ismael, Alaa Bassuny; Swelum, Ayman Abdel-Aziz; Mostafa, Salama A-H; Alhumiany, Abdel-Rahman A

    2016-09-01

    Brucellosis, especially caused by Brucella melitensis, is considered the most-widespread zoonosis in the world, particularly in developing countries. This study was planned to develop an accurate test for diagnosis of ovine brucellosis using a specific hot saline extracted soluble Brucella melitensis periplasmic proteins (SBPPs). The efficacy of the latex agglutination test (LAT) using SBPPs compared to the Rose Bengal test (RBT), buffered plate agglutination test (BPAT), serum agglutination test (SAT), and an indirect enzyme-linked immunosorbent assay (i-ELISA) was evaluated in the field diagnosis of ovine brucellosis. The test performance was evaluated by estimating sensitivity (Se), specificity (Sp), positive predictive value (PPV), negative predictive value (NPV), disease prevalence (DP), positive likelihood ratio (PLR), and negative likelihood ratio (NLR) using test agreement and bacteriological culture in 1777 samples. The false-positive result was significantly (P ⩽0.05) lower in LAT than RBT, BPAT, SAT, and i-ELISA. With reference to test agreement, the Se, Sp, PPV, and PLR were highest (P ⩽0.05) in LAT 99.33%, 99.88%, 98.68%, and 827.25%, respectively. With reference to bacteriological culture, the LAT and i-ELISA tests showed a significant difference in Se with SAT. However, no significant difference in specificity was detected. The DP was 8.44% in the five tests. In conclusion, LAT using SBPPs of B. melitensis could be a suitable serodiagnostic field test for ovine brucellosis, with high sensitivity and specificity. © The Author(s) 2016.

  8. STUDIES ON THE BIOLOGY OF STREPTOCOCCUS

    PubMed Central

    Bliss, Walter Parks

    1922-01-01

    1. Hemolytic streptococcus has been found in 100 per cent of the throats of patients with scarlet fever during the 1st week of the disease. 2. The average length of time that these organisms are present in the throat varies from 10 to 20 days. 3. No morphological or cultural characteristics peculiar to the hemolytic streptococcus from scarlet fever can be demonstrated. 4. Ten immune sera have been prepared from different strains of scarlet fever streptococci and each of the sera agglutinated more than 80 per cent of the strains isolated from scarlatinal throats. On the other hand, scarlatinal streptococci are not agglutinated by immune sera prepared from hemolytic streptococci isolated from other pathological sources. 5. Serum from patients convalescent from scarlet fever agglutinates weakly or not at all the homologous strain of hemolytic streptococcus. 6. The specificity of the agglutination reaction of scarlatinal streptococci is confirmed by absorption experiments. 7. Scarlatinal antistreptococcic serum affords some degree of protection against virulent scarlet fever streptococci but has no protective power against hemolytic streptococci from other diseases. 8. In a small epidemic of scarlet fever a healthy carrier of hemolytic streptococcus was detected; the organism carried was identical in its serological reactions with strains of hemolytic streptococci isolated from active cases of scarlet fever. 9. In a study of a number of contacts with a case of scarlet fever, in only one instance was a scarlatinal type of hemolytic streptococcus recovered from the throat. PMID:19868695

  9. Mechanisms of red blood cells agglutination in antibody-treated paper.

    PubMed

    Jarujamrus, Purim; Tian, Junfei; Li, Xu; Siripinyanond, Atitaya; Shiowatana, Juwadee; Shen, Wei

    2012-05-07

    Recent reports on using bio-active paper and bio-active thread to determine human blood type have shown a tremendous potential of using these low-cost materials to build bio-sensors for blood diagnosis. In this work we focus on understanding the mechanisms of red blood cell agglutination in the antibody-loaded paper. We semi-quantitatively evaluate the percentage of antibody molecules that are adsorbed on cellulose fibres and can potentially immobilize red blood cells on the fibre surface, and the percentage of the molecules that can desorb from the cellulose fibre surface into the blood sample and cause haemagglutination reaction in the bulk of a blood sample. Our results show that 34 to 42% of antibody molecules in the papers treated with commercial blood grouping antibodies can desorb from the fibre surface. When specific antibody molecules are released into the blood sample via desorption, haemagglutination reaction occurs in the blood sample. The reaction bridges the red cells in the blood sample bulk to the layer of red cells immobilized on the fibre surface by the adsorbed antibody molecules. The desorbed antibody also causes agglutinated lumps of red blood cells to form. These lumps cannot pass through the pores of the filter paper. The immobilization and filtration of agglutinated red cells give reproducible identification of positive haemagglutination reaction. Results from this study provide information for designing new bio-active paper-based devices for human blood typing with improved sensitivity and specificity.

  10. Cryptosporidium Off-The-Slide Genotyping: Recovery of Oocysts Extracted from Slides Examined by Method 1623

    EPA Science Inventory

    Cryptosporidium has been found world wide and is an important waterborne parasite causing a self-limiting diarrhea; however, in the immunocompromised it may become chronic and can even lead to death. To characterize the risk of exposure to Cryptosporidium in water the USEPA enac...

  11. Enhancing Creative Thinking through Designing Electronic Slides

    ERIC Educational Resources Information Center

    Mokaram, Al-Ali Khaled; Al-Shabatat, Ahmad Mohammad; Fong, Fook Soon; Abdallah, Andaleeb Ahmad

    2011-01-01

    During the shifting of teaching and learning methods using computer technologies, much emphasis was paid on the knowledge content more than the thinking skills. Thus, this study investigated the effects of a computer application, namely, designing electronic slides on the development of creative thinking skills of a sample of undergraduate…

  12. Finite-time synchronization for second-order nonlinear multi-agent system via pinning exponent sliding mode control.

    PubMed

    Hou, Huazhou; Zhang, Qingling

    2016-11-01

    In this paper we investigate the finite-time synchronization for second-order multi-agent system via pinning exponent sliding mode control. Firstly, for the nonlinear multi-agent system, differential mean value theorem is employed to transfer the nonlinear system into linear system, then, by pinning only one node in the system with novel exponent sliding mode control, we can achieve synchronization in finite time. Secondly, considering the 3-DOF helicopter system with nonlinear dynamics and disturbances, the novel exponent sliding mode control protocol is applied to only one node to achieve the synchronization. Finally, the simulation results show the effectiveness and the advantages of the proposed method. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.

  13. Advanced Interval Type-2 Fuzzy Sliding Mode Control for Robot Manipulator.

    PubMed

    Hwang, Ji-Hwan; Kang, Young-Chang; Park, Jong-Wook; Kim, Dong W

    2017-01-01

    In this paper, advanced interval type-2 fuzzy sliding mode control (AIT2FSMC) for robot manipulator is proposed. The proposed AIT2FSMC is a combination of interval type-2 fuzzy system and sliding mode control. For resembling a feedback linearization (FL) control law, interval type-2 fuzzy system is designed. For compensating the approximation error between the FL control law and interval type-2 fuzzy system, sliding mode controller is designed, respectively. The tuning algorithms are derived in the sense of Lyapunov stability theorem. Two-link rigid robot manipulator with nonlinearity is used to test and the simulation results are presented to show the effectiveness of the proposed method that can control unknown system well.

  14. Color standardization and optimization in whole slide imaging.

    PubMed

    Yagi, Yukako

    2011-03-30

    Standardization and validation of the color displayed by digital slides is an important aspect of digital pathology implementation. While the most common reason for color variation is the variance in the protocols and practices in the histology lab, the color displayed can also be affected by variation in capture parameters (for example, illumination and filters), image processing and display factors in the digital systems themselves. We have been developing techniques for color validation and optimization along two paths. The first was based on two standard slides that are scanned and displayed by the imaging system in question. In this approach, one slide is embedded with nine filters with colors selected especially for H&E stained slides (looking like tiny Macbeth color chart); the specific color of the nine filters were determined in our previous study and modified for whole slide imaging (WSI). The other slide is an H&E stained mouse embryo. Both of these slides were scanned and the displayed images were compared to a standard. The second approach was based on our previous multispectral imaging research. As a first step, the two slide method (above) was used to identify inaccurate display of color and its cause, and to understand the importance of accurate color in digital pathology. We have also improved the multispectral-based algorithm for more consistent results in stain standardization. In near future, the results of the two slide and multispectral techniques can be combined and will be widely available. We have been conducting a series of researches and developing projects to improve image quality to establish Image Quality Standardization. This paper discusses one of most important aspects of image quality - color.

  15. Pork Meat as a Potential Source of Salmonella enterica subsp. arizonae Infection in Humans

    PubMed Central

    Kritas, Spyridon; Govaris, Alexander; Burriel, Angeliki R.

    2014-01-01

    Salmonella enterica subsp. arizonae was isolated from 13 of 123 slaughtered pigs in central Greece. The samples cultured were feces, ileum tissue, mesenteric lymph nodes, and gallbladder swabs. A total of 74 isolates from 492 samples were identified as Salmonella spp. by use of standard laboratory culture media and two commercial micromethods and by use of a polyvalent slide agglutination test for the detection of O and H antigens. Among them were 19 (25.68%) suspected to be S. enterica subsp. arizonae according to analysis with standard laboratory culture media. Of those, 14 were identified as S. enterica subsp. arizonae by the API 20E (bioMérieux, France) and the Microgen GnA+B-ID (Microgen Bioproducts, Ltd., United Kingdom) identification systems. All the isolates were tested for resistance to 23 antimicrobials. Strains identified as S. enterica subsp. arizonae were resistant to 17 (70.8%) antibiotics. The highest proportions of resistance were observed for sulfamethoxazole-trimethoprim (71.4%), tetracycline (71.4%), ampicillin (64.3%), and amoxicillin (57.1%). Two isolates were resistant to aztreonam (7.1%) and tigecycline (7.1%), used only for the treatment of humans. Thus, pork meat may play a role in the transmission of antibiotic-resistant S. enterica subsp. arizonae to human consumers. This is the first report of S. enterica subsp. arizonae isolation from pigs. PMID:24335956

  16. Pork meat as a potential source of Salmonella enterica subsp. arizonae infection in humans.

    PubMed

    Evangelopoulou, Grammato; Kritas, Spyridon; Govaris, Alexander; Burriel, Angeliki R

    2014-03-01

    Salmonella enterica subsp. arizonae was isolated from 13 of 123 slaughtered pigs in central Greece. The samples cultured were feces, ileum tissue, mesenteric lymph nodes, and gallbladder swabs. A total of 74 isolates from 492 samples were identified as Salmonella spp. by use of standard laboratory culture media and two commercial micromethods and by use of a polyvalent slide agglutination test for the detection of O and H antigens. Among them were 19 (25.68%) suspected to be S. enterica subsp. arizonae according to analysis with standard laboratory culture media. Of those, 14 were identified as S. enterica subsp. arizonae by the API 20E (bioMérieux, France) and the Microgen GnA+B-ID (Microgen Bioproducts, Ltd., United Kingdom) identification systems. All the isolates were tested for resistance to 23 antimicrobials. Strains identified as S. enterica subsp. arizonae were resistant to 17 (70.8%) antibiotics. The highest proportions of resistance were observed for sulfamethoxazole-trimethoprim (71.4%), tetracycline (71.4%), ampicillin (64.3%), and amoxicillin (57.1%). Two isolates were resistant to aztreonam (7.1%) and tigecycline (7.1%), used only for the treatment of humans. Thus, pork meat may play a role in the transmission of antibiotic-resistant S. enterica subsp. arizonae to human consumers. This is the first report of S. enterica subsp. arizonae isolation from pigs.

  17. A method for normalizing pathology images to improve feature extraction for quantitative pathology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tam, Allison; Barker, Jocelyn; Rubin, Daniel

    Purpose: With the advent of digital slide scanning technologies and the potential proliferation of large repositories of digital pathology images, many research studies can leverage these data for biomedical discovery and to develop clinical applications. However, quantitative analysis of digital pathology images is impeded by batch effects generated by varied staining protocols and staining conditions of pathological slides. Methods: To overcome this problem, this paper proposes a novel, fully automated stain normalization method to reduce batch effects and thus aid research in digital pathology applications. Their method, intensity centering and histogram equalization (ICHE), normalizes a diverse set of pathology imagesmore » by first scaling the centroids of the intensity histograms to a common point and then applying a modified version of contrast-limited adaptive histogram equalization. Normalization was performed on two datasets of digitized hematoxylin and eosin (H&E) slides of different tissue slices from the same lung tumor, and one immunohistochemistry dataset of digitized slides created by restaining one of the H&E datasets. Results: The ICHE method was evaluated based on image intensity values, quantitative features, and the effect on downstream applications, such as a computer aided diagnosis. For comparison, three methods from the literature were reimplemented and evaluated using the same criteria. The authors found that ICHE not only improved performance compared with un-normalized images, but in most cases showed improvement compared with previous methods for correcting batch effects in the literature. Conclusions: ICHE may be a useful preprocessing step a digital pathology image processing pipeline.« less

  18. Deep Learning for Classification of Colorectal Polyps on Whole-slide Images

    PubMed Central

    Korbar, Bruno; Olofson, Andrea M.; Miraflor, Allen P.; Nicka, Catherine M.; Suriawinata, Matthew A.; Torresani, Lorenzo; Suriawinata, Arief A.; Hassanpour, Saeed

    2017-01-01

    Context: Histopathological characterization of colorectal polyps is critical for determining the risk of colorectal cancer and future rates of surveillance for patients. However, this characterization is a challenging task and suffers from significant inter- and intra-observer variability. Aims: We built an automatic image analysis method that can accurately classify different types of colorectal polyps on whole-slide images to help pathologists with this characterization and diagnosis. Setting and Design: Our method is based on deep-learning techniques, which rely on numerous levels of abstraction for data representation and have shown state-of-the-art results for various image analysis tasks. Subjects and Methods: Our method covers five common types of polyps (i.e., hyperplastic, sessile serrated, traditional serrated, tubular, and tubulovillous/villous) that are included in the US Multisociety Task Force guidelines for colorectal cancer risk assessment and surveillance. We developed multiple deep-learning approaches by leveraging a dataset of 2074 crop images, which were annotated by multiple domain expert pathologists as reference standards. Statistical Analysis: We evaluated our method on an independent test set of 239 whole-slide images and measured standard machine-learning evaluation metrics of accuracy, precision, recall, and F1 score and their 95% confidence intervals. Results: Our evaluation shows that our method with residual network architecture achieves the best performance for classification of colorectal polyps on whole-slide images (overall accuracy: 93.0%, 95% confidence interval: 89.0%–95.9%). Conclusions: Our method can reduce the cognitive burden on pathologists and improve their efficacy in histopathological characterization of colorectal polyps and in subsequent risk assessment and follow-up recommendations. PMID:28828201

  19. Validation of various adaptive threshold methods of segmentation applied to follicular lymphoma digital images stained with 3,3’-Diaminobenzidine&Haematoxylin

    PubMed Central

    2013-01-01

    The comparative study of the results of various segmentation methods for the digital images of the follicular lymphoma cancer tissue section is described in this paper. The sensitivity and specificity and some other parameters of the following adaptive threshold methods of segmentation: the Niblack method, the Sauvola method, the White method, the Bernsen method, the Yasuda method and the Palumbo method, are calculated. Methods are applied to three types of images constructed by extraction of the brown colour information from the artificial images synthesized based on counterpart experimentally captured images. This paper presents usefulness of the microscopic image synthesis method in evaluation as well as comparison of the image processing results. The results of thoughtful analysis of broad range of adaptive threshold methods applied to: (1) the blue channel of RGB, (2) the brown colour extracted by deconvolution and (3) the ’brown component’ extracted from RGB allows to select some pairs: method and type of image for which this method is most efficient considering various criteria e.g. accuracy and precision in area detection or accuracy in number of objects detection and so on. The comparison shows that the White, the Bernsen and the Sauvola methods results are better than the results of the rest of the methods for all types of monochromatic images. All three methods segments the immunopositive nuclei with the mean accuracy of 0.9952, 0.9942 and 0.9944 respectively, when treated totally. However the best results are achieved for monochromatic image in which intensity shows brown colour map constructed by colour deconvolution algorithm. The specificity in the cases of the Bernsen and the White methods is 1 and sensitivities are: 0.74 for White and 0.91 for Bernsen methods while the Sauvola method achieves sensitivity value of 0.74 and the specificity value of 0.99. According to Bland-Altman plot the Sauvola method selected objects are segmented without undercutting the area for true positive objects but with extra false positive objects. The Sauvola and the Bernsen methods gives complementary results what will be exploited when the new method of virtual tissue slides segmentation be develop. Virtual Slides The virtual slides for this article can be found here: slide 1: http://diagnosticpathology.slidepath.com/dih/webViewer.php?snapshotId=13617947952577 and slide 2: http://diagnosticpathology.slidepath.com/dih/webViewer.php?snapshotId=13617948230017. PMID:23531405

  20. Molecular identification of Mycoplasma synoviae from seroprevalent commercial breeder farms at Chittagong district, Bangladesh

    PubMed Central

    Uddin, Md. Inkeyas; Abid, Md. Harisul; Islam, Md. Shafiqul; Rakib, Tofazzal Md.; Sen, Ashim Baran; Chowdhury, Shah Mohammed Ziqrul Haq; Anwar, Md. Nurul; Kamaruddin, Kazi Md.

    2016-01-01

    Aim: Worldwide, Mycoplasma synoviae (MS) is an important pathogen of poultry, especially for chicken and turkey. It causes respiratory tract infection and infectious sinusitis. The study was conducted to determine the seroprevalence of MS infection with associated risk factors and identification of MS organism in unvaccinated flocks of commercial breeder farms of the Chittagong district, Bangladesh. Materials and Methods: A total of 365 serum samples were collected and tested for MS using serum plate agglutination (SPA) test for determination of MS seroprevalence. On the other hand, tracheal swabs were collected from each seropositive flocks for polymerase chain reaction (PCR) to determine the presence of MS organism. Results: Among the farms, the highest prevalence was found to be 69% and the lowest prevalence was 28% with the average 60%. The seroprevalence of MS infection in breeder farms was highest 70% with the flock size >10,000 birds, whereas it was lowest 57% in the flocks ranging from 4000 to 7000. According to age group, the prevalence was found highest 70% in >60 weeks age group of birds and lowest 42% in 10-19 weeks group. The seroprevalence of MS in winter season was found as highest as 64%, whereas it was found lowest 60% in the summer season. There was a statistically significant difference (p<0.01) among the seroprevalence of MS in different breeder farms, flock size, and age groups, but there was no significant (p>0.05) difference in the winter, summer, and rainy season. To confirm the presence of MS in the samples, PCR test was applied using specific primers to amplify a 214 bp region of the 16S rRNA gene of the organism. In PCR, all seropositive flocks showed a positive result for MS. Conclusion: As the plate agglutination test result showed 100% similar with PCR result, it can be suggested that agglutination test is better than molecular and culture techniques for MS detection and it is also cheaper and less time-consuming method. PMID:27847414

  1. Smith predictor with sliding mode control for processes with large dead times

    NASA Astrophysics Data System (ADS)

    Mehta, Utkal; Kaya, İbrahim

    2017-11-01

    The paper discusses the Smith Predictor scheme with Sliding Mode Controller (SP-SMC) for processes with large dead times. This technique gives improved load-disturbance rejection with optimum input control signal variations. A power rate reaching law is incorporated in the sporadic part of sliding mode control such that the overall performance recovers meaningfully. The proposed scheme obtains parameter values by satisfying a new performance index which is based on biobjective constraint. In simulation study, the efficiency of the method is evaluated for robustness and transient performance over reported techniques.

  2. Leader–follower fixed-time consensus of multi-agent systems with high-order integrator dynamics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tian, Bailing; Zuo, Zongyu; Wang, Hong

    The leader-follower fixed-time consensus of high-order multi-agent systems with external disturbances is investigated in this paper. A novel sliding manifold is designed to ensure that the tracking errors converge to zero in a fixed-time during the sliding motion. Then, a distributed control law is designed based on Lyapunov technique to drive the system states to the sliding manifold in finite-time independent of initial conditions. Finally, the efficiency of the proposed method is illustrated by numerical simulations.

  3. Block Slides on Extremely Weak Tectonic Clay Seams in Openly Folded Tertiary Mud-Rocks at Auckland and the Rangitikei Valley, North Island, New Zealand

    NASA Astrophysics Data System (ADS)

    Prebble, Warwick M.; Williams, Ann L.

    2016-06-01

    Block slides have developed on extremely weak, thin clay seams of tectonic origin, parallel to bedding in gently dipping sandstones and mudstones of Tertiary age. Two areas of noted instability are investigated at Auckland and the Rangitikei valley. Dimensions range from 100 m across × 100 m long for short displacement block slides up to 4 km across × 3 km long for large landslide complexes in which block slides are a major component. Displacements of blocks range from incipient (cm) through short (30 m) to 2 or 3 km for large slides. Many of the Auckland slides are dormant but likely to move in a 2000 year return period earthquake or 100 year high intensity rain storm. At Rangitikei there are many active, younger slides. Sliding rates for active failures vary from a few cm/year to 50 m in 30 min. Host rocks are weak to very weak clayey sandstones and sandy mudstones. The seams are rich in smectite. They have polished and crushed walls, may have slickensides and some contain rounded rock fragments. Laboratory shear strength of the seams is 13 kPa cohesion and 13° friction, with a lower bound of 8° at zero cohesion. Strength is increased at the field scale by waviness, steps and splays. Continuity can be demonstrated over distances of hundreds of metres. Key investigation methods were mapping, shafts and trenches. Tectonic uplift, folding and faulting of the weak Tertiary strata and river down-cutting are perpetuating block slide development.

  4. Cholera studies*

    PubMed Central

    Pollitzer, R.

    1956-01-01

    The first portion of this study describes in detail the different aspects of stool examinations, including the collection, preservation, and pooling of specimens, macroscopic and bacterioscopic examination, enrichment methods, and cultivation on a variety of solid media. The author also deals with the examination of vomits and of water. The performance and value of different identification tests (agglutination, haemolysis, and bacteriophage) and confirmatory tests are then considered. An annex is included on bacteriological procedures in the laboratory diagnosis of cholera. PMID:13356145

  5. [A novel M142T mutation in the B glycosyltransferase gene associated with B3 variant in Chinese].

    PubMed

    Xu, Xian-guo; Hong, Xiao-zhen; Liu, Ying; Zhu, Fa-ming; Lv, Hang-jun; Yan, Li-xing

    2009-06-01

    To investigate the molecular genetic basis of the B3 variant of ABO blood group system with mixed-field hemagglutination in Chinese. Serological techniques were performed to characterize the erythrocyte phenotype of two discrepant samples. A sequential agglutination method and 13 short tandem repeat (STR) loci were tested to exclude the possibility of exogenous or endogenous DNA chimera. Mutations in exons 6 and 7, including partial intron of the ABO gene, were screened by polymerase chain reaction and DNA sequencing. Haplotypes of the two individuals were also analyzed by sequencing. A mixed-field hemagglutination of RBCs with anti-B and anti-AB antibodies was detected in the two unrelated individuals. Exogenous ABO-incompatible RBC transfusion and endogenous genetic chimera were excluded by sequential agglutination method and STR. The ABO phenotypes of the two individuals were classified as A1B3 according to the ABO subgroup definition. The sequence region from intron 5 to 3'-UTR of the B allele was identical to that of ABO*B101 allele, except for a T to C substitution at nucleotide position 425 in exon 7. This substitution resulted in an amino acid change of M142T in the B glycosyltransferase. A novel B allele with 425T>C substitution resulting in B3 subgroup was identified in two Chinese individuals.

  6. Mouse cursor movement and eye tracking data as an indicator of pathologists’ attention when viewing digital whole slide images

    PubMed Central

    Raghunath, Vignesh; Braxton, Melissa O.; Gagnon, Stephanie A.; Brunyé, Tad T.; Allison, Kimberly H.; Reisch, Lisa M.; Weaver, Donald L.; Elmore, Joann G.; Shapiro, Linda G.

    2012-01-01

    Context: Digital pathology has the potential to dramatically alter the way pathologists work, yet little is known about pathologists’ viewing behavior while interpreting digital whole slide images. While tracking pathologist eye movements when viewing digital slides may be the most direct method of capturing pathologists’ viewing strategies, this technique is cumbersome and technically challenging to use in remote settings. Tracking pathologist mouse cursor movements may serve as a practical method of studying digital slide interpretation, and mouse cursor data may illuminate pathologists’ viewing strategies and time expenditures in their interpretive workflow. Aims: To evaluate the utility of mouse cursor movement data, in addition to eye-tracking data, in studying pathologists’ attention and viewing behavior. Settings and Design: Pathologists (N = 7) viewed 10 digital whole slide images of breast tissue that were selected using a random stratified sampling technique to include a range of breast pathology diagnoses (benign/atypia, carcinoma in situ, and invasive breast cancer). A panel of three expert breast pathologists established a consensus diagnosis for each case using a modified Delphi approach. Materials and Methods: Participants’ foveal vision was tracked using SensoMotoric Instruments RED 60 Hz eye-tracking system. Mouse cursor movement was tracked using a custom MATLAB script. Statistical Analysis Used: Data on eye-gaze and mouse cursor position were gathered at fixed intervals and analyzed using distance comparisons and regression analyses by slide diagnosis and pathologist expertise. Pathologists’ accuracy (defined as percent agreement with the expert consensus diagnoses) and efficiency (accuracy and speed) were also analyzed. Results: Mean viewing time per slide was 75.2 seconds (SD = 38.42). Accuracy (percent agreement with expert consensus) by diagnosis type was: 83% (benign/atypia); 48% (carcinoma in situ); and 93% (invasive). Spatial coupling was close between eye-gaze and mouse cursor positions (highest frequency ∆x was 4.00px (SD = 16.10), and ∆y was 37.50px (SD = 28.08)). Mouse cursor position moderately predicted eye gaze patterns (Rx = 0.33 and Ry = 0.21). Conclusions: Data detailing mouse cursor movements may be a useful addition to future studies of pathologists’ accuracy and efficiency when using digital pathology. PMID:23372984

  7. Rock Slide Risk Assessment: A Semi-Quantitative Approach

    NASA Astrophysics Data System (ADS)

    Duzgun, H. S. B.

    2009-04-01

    Rock slides can be better managed by systematic risk assessments. Any risk assessment methodology for rock slides involves identification of rock slide risk components, which are hazard, elements at risk and vulnerability. For a quantitative/semi-quantitative risk assessment for rock slides, a mathematical value the risk has to be computed and evaluated. The quantitative evaluation of risk for rock slides enables comparison of the computed risk with the risk of other natural and/or human-made hazards and providing better decision support and easier communication for the decision makers. A quantitative/semi-quantitative risk assessment procedure involves: Danger Identification, Hazard Assessment, Elements at Risk Identification, Vulnerability Assessment, Risk computation, Risk Evaluation. On the other hand, the steps of this procedure require adaptation of existing or development of new implementation methods depending on the type of landslide, data availability, investigation scale and nature of consequences. In study, a generic semi-quantitative risk assessment (SQRA) procedure for rock slides is proposed. The procedure has five consecutive stages: Data collection and analyses, hazard assessment, analyses of elements at risk and vulnerability and risk assessment. The implementation of the procedure for a single rock slide case is illustrated for a rock slope in Norway. Rock slides from mountain Ramnefjell to lake Loen are considered to be one of the major geohazards in Norway. Lake Loen is located in the inner part of Nordfjord in Western Norway. Ramnefjell Mountain is heavily jointed leading to formation of vertical rock slices with height between 400-450 m and width between 7-10 m. These slices threaten the settlements around Loen Valley and tourists visiting the fjord during summer season, as the released slides have potential of creating tsunami. In the past, several rock slides had been recorded from the Mountain Ramnefjell between 1905 and 1950. Among them, four of the slides caused formation of tsunami waves which washed up to 74 m above the lake level. Two of the slides resulted in many fatalities in the inner part of the Loen Valley as well as great damages. There are three predominant joint structures in Ramnefjell Mountain, which controls failure and the geometry of the slides. The first joint set is a foliation plane striking northeast-southwest and dipping 35˚ -40˚ to the east-southeast. The second and the third joint sets are almost perpendicular and parallel to the mountain side and scarp, respectively. These three joint sets form slices of rock columns with width ranging between 7-10 m and height of 400-450 m. It is stated that the joints in set II are opened between 1-2 m, which may bring about collection of water during heavy rainfall or snow melt causing the slices to be pressed out. It is estimated that water in the vertical joints both reduces the shear strength of sliding plane and causes reduction of normal stress on the sliding plane due to formation of uplift force. Hence rock slides in Ramnefjell mountain occur in plane failure mode. The quantitative evaluation of rock slide risk requires probabilistic analysis of rock slope stability and identification of consequences if the rock slide occurs. In this study failure probability of a rock slice is evaluated by first-order reliability method (FORM). Then in order to use the calculated probability of failure value (Pf) in risk analyses, it is required to associate this Pf with frequency based probabilities (i.ePf / year) since the computed failure probabilities is a measure of hazard and not a measure of risk unless they are associated with the consequences of the failure. This can be done by either considering the time dependent behavior of the basic variables in the probabilistic models or associating the computed Pf with frequency of the failures in the region. In this study, the frequency of previous rock slides in the previous century in Remnefjell is used for evaluation of frequency based probability to be used in risk assessment. The major consequence of a rock slide is generation of a tsunami in the lake Loen, causing inundation of residential areas around the lake. Risk is assessed by adapting damage probability matrix approach, which is originally developed for risk assessment for buildings in case of earthquake.

  8. Comparison of the manual, semiautomatic, and automatic selection and leveling of hot spots in whole slide images for Ki-67 quantification in meningiomas.

    PubMed

    Swiderska, Zaneta; Korzynska, Anna; Markiewicz, Tomasz; Lorent, Malgorzata; Zak, Jakub; Wesolowska, Anna; Roszkowiak, Lukasz; Slodkowska, Janina; Grala, Bartlomiej

    2015-01-01

    Background. This paper presents the study concerning hot-spot selection in the assessment of whole slide images of tissue sections collected from meningioma patients. The samples were immunohistochemically stained to determine the Ki-67/MIB-1 proliferation index used for prognosis and treatment planning. Objective. The observer performance was examined by comparing results of the proposed method of automatic hot-spot selection in whole slide images, results of traditional scoring under a microscope, and results of a pathologist's manual hot-spot selection. Methods. The results of scoring the Ki-67 index using optical scoring under a microscope, software for Ki-67 index quantification based on hot spots selected by two pathologists (resp., once and three times), and the same software but on hot spots selected by proposed automatic methods were compared using Kendall's tau-b statistics. Results. Results show intra- and interobserver agreement. The agreement between Ki-67 scoring with manual and automatic hot-spot selection is high, while agreement between Ki-67 index scoring results in whole slide images and traditional microscopic examination is lower. Conclusions. The agreement observed for the three scoring methods shows that automation of area selection is an effective tool in supporting physicians and in increasing the reliability of Ki-67 scoring in meningioma.

  9. Comparison of the Manual, Semiautomatic, and Automatic Selection and Leveling of Hot Spots in Whole Slide Images for Ki-67 Quantification in Meningiomas

    PubMed Central

    Swiderska, Zaneta; Korzynska, Anna; Markiewicz, Tomasz; Lorent, Malgorzata; Zak, Jakub; Wesolowska, Anna; Roszkowiak, Lukasz; Slodkowska, Janina; Grala, Bartlomiej

    2015-01-01

    Background. This paper presents the study concerning hot-spot selection in the assessment of whole slide images of tissue sections collected from meningioma patients. The samples were immunohistochemically stained to determine the Ki-67/MIB-1 proliferation index used for prognosis and treatment planning. Objective. The observer performance was examined by comparing results of the proposed method of automatic hot-spot selection in whole slide images, results of traditional scoring under a microscope, and results of a pathologist's manual hot-spot selection. Methods. The results of scoring the Ki-67 index using optical scoring under a microscope, software for Ki-67 index quantification based on hot spots selected by two pathologists (resp., once and three times), and the same software but on hot spots selected by proposed automatic methods were compared using Kendall's tau-b statistics. Results. Results show intra- and interobserver agreement. The agreement between Ki-67 scoring with manual and automatic hot-spot selection is high, while agreement between Ki-67 index scoring results in whole slide images and traditional microscopic examination is lower. Conclusions. The agreement observed for the three scoring methods shows that automation of area selection is an effective tool in supporting physicians and in increasing the reliability of Ki-67 scoring in meningioma. PMID:26240787

  10. The Stability Analysis Method of the Cohesive Granular Slope on the Basis of Graph Theory

    PubMed Central

    Guan, Yanpeng; Liu, Xiaoli; Wang, Enzhi; Wang, Sijing

    2017-01-01

    This paper attempted to provide a method to calculate progressive failure of the cohesive-frictional granular geomaterial and the spatial distribution of the stability of the cohesive granular slope. The methodology can be divided into two parts: the characterization method of macro-contact and the analysis of the slope stability. Based on the graph theory, the vertexes, the edges and the edge sequences are abstracted out to characterize the voids, the particle contact and the macro-contact, respectively, bridging the gap between the mesoscopic and macro scales of granular materials. This paper adopts this characterization method to extract a graph from a granular slope and characterize the macro sliding surface, then the weighted graph is analyzed to calculate the slope safety factor. Each edge has three weights representing the sliding moment, the anti-sliding moment and the braking index of contact-bond, respectively, E1E2E3E1E2E3. The safety factor of the slope is calculated by presupposing a certain number of sliding routes and reducing Weight E3 repeatedly and counting the mesoscopic failure of the edge. It is a kind of slope analysis method from mesoscopic perspective so it can present more detail of the mesoscopic property of the granular slope. In the respect of macro scale, the spatial distribution of the stability of the granular slope is in agreement with the theoretical solution. PMID:28772596

  11. Landslide tsunami hazard in New South Wales, Australia: novel observations from 3D modelling

    NASA Astrophysics Data System (ADS)

    Power, Hannah; Clarke, Samantha; Hubble, Tom

    2015-04-01

    This paper examines the potential of tsunami inundation generated from two case study sites of submarine mass failures on the New South Wales coast of Australia. Two submarine mass failure events are investigated: the Bulli Slide and the Shovel Slide. Both slides are located approximately 65 km southeast of Sydney and 60 km east of the township of Wollongong. The Bulli Slide (~20 km3) and the Shovel Slide (7.97 km3) correspond to the two largest identified erosional surface submarine landslides scars of the NSW continental margin (Glenn et al. 2008; Clarke 2014) and represent examples of large to very large submarine landslide scars. The Shovel Slide is a moderately thick (80-165 m), moderately wide to wide (4.4 km) slide, and is located in 880 m water depth; and the Bulli Slide is an extremely thick (200-425 m), very wide (8.9 km) slide, and is located in 1500 m water depth. Previous work on the east Australian margin (Clarke et al., 2014) and elsewhere (Harbitz et al., 2013) suggests that submarine landslides similar to the Bulli Slide or the Shovel Slide are volumetrically large enough and occur at shallow enough water depths (400-2500 m) to generate substantial tsunamis that could cause widespread damage on the east Australian coast and threaten coastal communities (Burbidge et al. 2008; Clarke 2014; Talukder and Volker 2014). Currently, the tsunamogenic potential of these two slides has only been investigated using 2D modelling (Clarke 2014) and to date it has been difficult to establish the onshore tsunami surge characteristics for the submarine landslides with certainty. To address this knowledge gap, the forecast inundation as a result of these two mass failure events was investigated using a three-dimensional model (ANUGA) that predicts water flow resulting from natural hazard events such as tsunami (Nielsen et al., 2005). The ANUGA model solves the two-dimensional shallow water wave equations and accurately models the process of wetting and drying thus making it ideal for simulating inundation due to tsunami. The model generates a surface wave profile based on the dimensions of the submarine mass failure event using the method of Ward et al. (2005). Inundation maps are shown for these two slides and sensitivity analysis is conducted to identify the characteristics of the slides that are most influential on inundation areas and depths.

  12. Art History Interactive Videodisc Project at the University of Iowa.

    ERIC Educational Resources Information Center

    Sustik, Joan M.

    A project which developed a retrieval system to evaluate the advantages and disadvantages of an interactive computer and video display system over traditional methods for using a slide library is described in this publication. The art school slide library of the University of Iowa stores transparencies which are arranged alphabetically within…

  13. An Investigation of the Incorporation of Virtual Microscopy in the Cytotechnology Educational Curriculum

    ERIC Educational Resources Information Center

    Mukherjee, Maheswari S.

    2012-01-01

    Traditionally, cytotechnology (CT) students have been trained by using light microscopy (LM) and glass slides. However, this method of training has some drawbacks. Several other educational programs with similar issues have incorporated virtual microscopy (VM) in their curricula. In VM, the specimens on glass slides are converted into virtual…

  14. The Slide-Lecture: An Alternative to Chalkdust?

    ERIC Educational Resources Information Center

    Wilkins, S. A.

    Many instructors teaching large survey courses use the chalkboard to aid their lectures in spite of the waste of class time in writing and erasing, the clutter and confusion that may result, and the messiness of chalkdust. As an alternative, the slide-lecture method has been used for several years at Bossier Community College in teaching…

  15. Studying the Activities of Microorganisms in Soil Using Slides.

    ERIC Educational Resources Information Center

    Cullimore, D. Roy; Pipe, Annette E.

    1980-01-01

    Two implanted slide techniques are described by which activity of proteolylic bacteria and the growth of algae in the soil can be readily studied by school students using simple apparatus and methods. Variations are suggested for studying the effects of agricultural practices and environmental conditions on the soil bacteria and algae. (Author/DS)

  16. Sex-Role Learning: A Test of the Selective Attention Hypothesis

    ERIC Educational Resources Information Center

    Bryan, Janice Westlund; Luria, Zella

    1978-01-01

    Describes 2 experiments in which children ages 5-6 and 9-10 years viewed slides of male and female models performing matched acts which were sex-appropriate, sex-inappropriate, or sex-neutral. Visual attention was assessed by the method of feedback electroencephalography. Recall and preference for the slides were also measured. (Author/JMB)

  17. Whole slide imaging of unstained tissue using lensfree microscopy

    NASA Astrophysics Data System (ADS)

    Morel, Sophie Nhu An; Hervé, Lionel; Bordy, Thomas; Cioni, Olivier; Delon, Antoine; Fromentin, Catherine; Dinten, Jean-Marc; Allier, Cédric

    2016-04-01

    Pathologist examination of tissue slides provides insightful information about a patient's disease. Traditional analysis of tissue slides is performed under a binocular microscope, which requires staining of the sample and delays the examination. We present a simple cost-effective lensfree imaging method to record 2-4μm resolution wide-field (10 mm2 to 6 cm2) images of unstained tissue slides. The sample processing time is reduced as there is no need for staining. A wide field of view (10 mm2) lensfree hologram is recorded in a single shot and the image is reconstructed in 2s providing a very fast acquisition chain. The acquisition is multispectral, i.e. multiple holograms are recorded simultaneously at three different wavelengths, and a dedicated holographic reconstruction algorithm is used to retrieve both amplitude and phase. Whole tissue slides imaging is obtained by recording 130 holograms with X-Y translation stages and by computing the mosaic of a 25 x 25 mm2 reconstructed image. The reconstructed phase provides a phase-contrast-like image of the unstained specimen, revealing structures of healthy and diseased tissue. Slides from various organs can be reconstructed, e.g. lung, colon, ganglion, etc. To our knowledge, our method is the first technique that enables fast wide-field lensfree imaging of such unlabeled dense samples. This technique is much cheaper and compact than a conventional phase contrast microscope and could be made portable. In sum, we present a new methodology that could quickly provide useful information when a rapid diagnosis is needed, such as tumor margin identification on frozen section biopsies during surgery.

  18. Neural network-based sliding mode control for atmospheric-actuated spacecraft formation using switching strategy

    NASA Astrophysics Data System (ADS)

    Sun, Ran; Wang, Jihe; Zhang, Dexin; Shao, Xiaowei

    2018-02-01

    This paper presents an adaptive neural networks-based control method for spacecraft formation with coupled translational and rotational dynamics using only aerodynamic forces. It is assumed that each spacecraft is equipped with several large flat plates. A coupled orbit-attitude dynamic model is considered based on the specific configuration of atmospheric-based actuators. For this model, a neural network-based adaptive sliding mode controller is implemented, accounting for system uncertainties and external perturbations. To avoid invalidation of the neural networks destroying stability of the system, a switching control strategy is proposed which combines an adaptive neural networks controller dominating in its active region and an adaptive sliding mode controller outside the neural active region. An optimal process is developed to determine the control commands for the plates system. The stability of the closed-loop system is proved by a Lyapunov-based method. Comparative results through numerical simulations illustrate the effectiveness of executing attitude control while maintaining the relative motion, and higher control accuracy can be achieved by using the proposed neural-based switching control scheme than using only adaptive sliding mode controller.

  19. The virtual case: a new method to completely digitize cytological and histological slides.

    PubMed

    Demichelis, F; Barbareschi, M; Dalla Palma, P; Forti, S

    2002-08-01

    The purpose of this study was to present a new method for handling histological/cytological cases. Thanks to the introduction of information technology in pathology, including the amenities afforded by robotic microscopes and digital imaging, tissue slides can be represented and evaluated using digital techniques in order to construct virtual cases through completely automated procedures. A virtual case (VC) is composed of a collection of digital images representing a histological/cytological slide at all magnification levels together with all relevant clinical data. In the present study, we describe an automated system to manage robotic microscope and image acquisition for the proper construction of VCs. These can then be viewed on a computer by means of an interface ("user-friendly") that allows one to select the more appropriate fields and to examine them at different magnifications, rapidly going from panoramic views to high resolution and vice versa. In comparison with glass slides, VCs have several advantages arising from their digital nature and can be considered a common platform for a wide range of applications such as teleconsultation, education, research, and quality control and proficiency tests.

  20. Sliding Mode Fault Tolerant Control with Adaptive Diagnosis for Aircraft Engines

    NASA Astrophysics Data System (ADS)

    Xiao, Lingfei; Du, Yanbin; Hu, Jixiang; Jiang, Bin

    2018-03-01

    In this paper, a novel sliding mode fault tolerant control method is presented for aircraft engine systems with uncertainties and disturbances on the basis of adaptive diagnostic observer. By taking both sensors faults and actuators faults into account, the general model of aircraft engine control systems which is subjected to uncertainties and disturbances, is considered. Then, the corresponding augmented dynamic model is established in order to facilitate the fault diagnosis and fault tolerant controller design. Next, a suitable detection observer is designed to detect the faults effectively. Through creating an adaptive diagnostic observer and based on sliding mode strategy, the sliding mode fault tolerant controller is constructed. Robust stabilization is discussed and the closed-loop system can be stabilized robustly. It is also proven that the adaptive diagnostic observer output errors and the estimations of faults converge to a set exponentially, and the converge rate greater than some value which can be adjusted by choosing designable parameters properly. The simulation on a twin-shaft aircraft engine verifies the applicability of the proposed fault tolerant control method.

  1. Robust current control-based generalized predictive control with sliding mode disturbance compensation for PMSM drives.

    PubMed

    Liu, Xudong; Zhang, Chenghui; Li, Ke; Zhang, Qi

    2017-11-01

    This paper addresses the current control of permanent magnet synchronous motor (PMSM) for electric drives with model uncertainties and disturbances. A generalized predictive current control method combined with sliding mode disturbance compensation is proposed to satisfy the requirement of fast response and strong robustness. Firstly, according to the generalized predictive control (GPC) theory based on the continuous time model, a predictive current control method is presented without considering the disturbance, which is convenient to be realized in the digital controller. In fact, it's difficult to derive the exact motor model and parameters in the practical system. Thus, a sliding mode disturbance compensation controller is studied to improve the adaptiveness and robustness of the control system. The designed controller attempts to combine the merits of both predictive control and sliding mode control, meanwhile, the controller parameters are easy to be adjusted. Lastly, the proposed controller is tested on an interior PMSM by simulation and experiment, and the results indicate that it has good performance in both current tracking and disturbance rejection. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  2. Deep Learning for Classification of Colorectal Polyps on Whole-slide Images.

    PubMed

    Korbar, Bruno; Olofson, Andrea M; Miraflor, Allen P; Nicka, Catherine M; Suriawinata, Matthew A; Torresani, Lorenzo; Suriawinata, Arief A; Hassanpour, Saeed

    2017-01-01

    Histopathological characterization of colorectal polyps is critical for determining the risk of colorectal cancer and future rates of surveillance for patients. However, this characterization is a challenging task and suffers from significant inter- and intra-observer variability. We built an automatic image analysis method that can accurately classify different types of colorectal polyps on whole-slide images to help pathologists with this characterization and diagnosis. Our method is based on deep-learning techniques, which rely on numerous levels of abstraction for data representation and have shown state-of-the-art results for various image analysis tasks. Our method covers five common types of polyps (i.e., hyperplastic, sessile serrated, traditional serrated, tubular, and tubulovillous/villous) that are included in the US Multisociety Task Force guidelines for colorectal cancer risk assessment and surveillance. We developed multiple deep-learning approaches by leveraging a dataset of 2074 crop images, which were annotated by multiple domain expert pathologists as reference standards. We evaluated our method on an independent test set of 239 whole-slide images and measured standard machine-learning evaluation metrics of accuracy, precision, recall, and F1 score and their 95% confidence intervals. Our evaluation shows that our method with residual network architecture achieves the best performance for classification of colorectal polyps on whole-slide images (overall accuracy: 93.0%, 95% confidence interval: 89.0%-95.9%). Our method can reduce the cognitive burden on pathologists and improve their efficacy in histopathological characterization of colorectal polyps and in subsequent risk assessment and follow-up recommendations.

  3. Adaptive backstepping sliding mode control with fuzzy monitoring strategy for a kind of mechanical system.

    PubMed

    Song, Zhankui; Sun, Kaibiao

    2014-01-01

    A novel adaptive backstepping sliding mode control (ABSMC) law with fuzzy monitoring strategy is proposed for the tracking-control of a kind of nonlinear mechanical system. The proposed ABSMC scheme combining the sliding mode control and backstepping technique ensure that the occurrence of the sliding motion in finite-time and the trajectory of tracking-error converge to equilibrium point. To obtain a better perturbation rejection property, an adaptive control law is employed to compensate the lumped perturbation. Furthermore, we introduce fuzzy monitoring strategy to improve adaptive capacity and soften the control signal. The convergence and stability of the proposed control scheme are proved by using Lyaponov's method. Finally, numerical simulations demonstrate the effectiveness of the proposed control scheme. © 2013 ISA. Published by Elsevier Ltd. All rights reserved.

  4. Comparison of a virtual microscope laboratory to a regular microscope laboratory for teaching histology.

    PubMed

    Harris, T; Leaven, T; Heidger, P; Kreiter, C; Duncan, J; Dick, F

    2001-02-01

    Emerging technology now exists to digitize a gigabyte of information from a glass slide, save it in a highly compressed file format, and deliver it over the web. By accessing these images with a standard web browser and viewer plug-in, a computer can emulate a real microscope and glass slide. Using this new technology, the immediate aims of our project were to digitize the glass slides from urinary tract, male genital, and endocrine units and implement them in the Spring 2000 Histology course at the University of Iowa, and to carry out a formative evaluation of the virtual slides of these three units in a side-by-side comparison with the regular microscope laboratory. The methods and results of this paper will describe the technology employed to create the virtual slides, and the formative evaluation carried out in the course. Anat Rec (New Anat) 265:10-14, 2001. Copyright 2001 Wiley-Liss, Inc.

  5. External quality assurance as a revalidation method for pathologists in pediatric histopathology: Comparison of four international programs

    PubMed Central

    Sergi, Consolato; Mikuz, Gregor

    2008-01-01

    Aim External quality assurance (EQA) is an extremely valuable resource for clinical pathologists to maintain high standards, improve diagnostic skills, and possibly revalidate medical license. The aim of this study was to participate in and compare four international slide survey programs (UK, IAP-Germany, USA-Canada, Australasia) in pediatric histopathology for clinical pathologists with the aim to use it as a revalidation method. Methods The following parameters were evaluated: number of circulations per year, number of slides, membership requirement, proof of significant pediatric pathology work, open to overseas participants, laboratory accreditation, issue of continuing professional development certificates and credits, slides discussion meeting, use of digital images, substandard performance letter, and anonymity of responses. Results The UK scheme, which has sampling procedure over several time frames (2 circulations/year, 30 slides), partial confidentiality, and multiple sources of data and assessors, can be used as a model for revalidation. The US-Canadian and Australasian schemes only partially fulfill the revalidation requirements. The IAP scheme appears to be essentially an educational program and may be unsuitable for revalidation. Conclusion The purposes and programs of EQA schemes vary worldwide. In order for it to be used for revalidation, it is advisable that EQA schemes are immediately unified. PMID:19014480

  6. Latex agglutination test (LAT) for the diagnosis of typhoid fever.

    PubMed

    Sahni, Gopal Shankar

    2013-06-01

    The efficacy of latex agglutination test in the rapid diagnosis of typhoid fever was studied and the result compared with that of blood culture. This study included 80 children suffering from typhoid fever, among which 40 were confirmed by blood culture isolation and 40 had possible typhoid fever based on high Widal's titre (a four-fold rise in the titre of antibody to typhi "O" and "H" antigen was considered as a positive Widal's test result). Eighty children, 40 with febrile illness confirmed to be other than typhoid and 40 normal healthy children were used as negative controls. The various groups were: (i) Study group ie, group I had 40 children confirmed by culture isolation of Salmonella typhi(confirmed typhoid cases). (ii) Control groups ie, (a) group II with 40 febrile controls selected from paediatrics ward where cause other than S typhi has been established, (b) group III with 40 afebrile healthy controls that were siblings of the children admitted in paediatric ward for any reason with no history of fever and TAB vaccination in the last one year, and (c) group IV with 40 children with high Widal's titre in paired sera sample. Widal's test with paired sera with a one week interval between collections were done in all 40 patients. Latex aggtutination test which could detect 900 ng/ml of antigen as observed in checker board titration, was positive in all 40 children from group I who had positive blood culture and in 30 children from group IV who had culture negative and had high Widal's titre positive. Latex agglutination test was positive in 4 children in group II and none in group III. Using blood culture positive cases as true positive and children in groups II and III as true negative, the test had a sensitivity of 100% and specificity of 96%. Latex agglutination test was found to be significantly sensitive (100%) and specific (96%) and could detect 75% more cases in group IV (possible typhoid cases). Thus latex agglutination test can be used for rapid diagnosis of typhoid fever though it cannot replace conventional blood culture required for isolation of organism to report the antibiotic sensitivity.

  7. The neuraminidases of MDCK grown human influenza A(H3N2) viruses isolated since 1994 can demonstrate receptor binding.

    PubMed

    Mohr, Peter G; Deng, Yi-Mo; McKimm-Breschkin, Jennifer L

    2015-04-22

    The neuraminidases (NAs) of MDCK passaged human influenza A(H3N2) strains isolated since 2005 are reported to have dual functions of cleavage of sialic acid and receptor binding. NA agglutination of red blood cells (RBCs) can be inhibited by neuraminidase inhibitors (NAIs), thus distinguishing it from haemagglutinin (HA) binding. We wanted to know if viruses prior to 2005 can demonstrate this property. Pairs of influenza A(H3N2) isolates ranging from 1993-2008 passaged in parallel only in eggs or in MDCK cells were tested for inhibition of haemagglutination by various NAIs. Only viruses isolated since 1994 and cultured in MDCK cells bound chicken RBCs solely through their NA. NAI inhibition of agglutination of turkey RBCs was seen for some, but not all of these same MDCK grown viruses. Efficacy of inhibition of enzyme activity and haemagglutination differed between NAIs. For many viruses lower concentrations of oseltamivir could inhibit agglutination compared to zanamivir, although they could both inhibit enzyme activity at comparable concentrations. An E119V mutation reduced sensitivity to oseltamivir and 4-aminoDANA for both the enzyme assay and inhibition of agglutination. Sequence analysis of the NAs and HAs of some paired viruses revealed mutations in the haemagglutinin of all egg passaged viruses. For many of the paired egg and MDCK cultured viruses we found no differences in their NA sequences by Sanger sequencing. However, deep sequencing of MDCK grown isolates revealed low levels of variant populations with mutations at either D151 or T148 in the NA, suggesting mutations at either site may be able to confer this property. The NA active site of MDCK cultured human influenza A(H3N2) viruses isolated since 1994 can express dual enzyme and receptor binding functions. Binding correlated with either D151 or T148 mutations. The catalytic and receptor binding sites do not appear to be structurally identical since relative concentrations of the NAIs to inhibit enzyme activity and agglutination differ.

  8. On decentralized adaptive full-order sliding mode control of multiple UAVs.

    PubMed

    Xiang, Xianbo; Liu, Chao; Su, Housheng; Zhang, Qin

    2017-11-01

    In this study, a novel decentralized adaptive full-order sliding mode control framework is proposed for the robust synchronized formation motion of multiple unmanned aerial vehicles (UAVs) subject to system uncertainty. First, a full-order sliding mode surface in a decentralized manner is designed to incorporate both the individual position tracking error and the synchronized formation error while the UAV group is engaged in building a certain desired geometric pattern in three dimensional space. Second, a decentralized virtual plant controller is constructed which allows the embedded low-pass filter to attain the chattering free property of the sliding mode controller. In addition, robust adaptive technique is integrated in the decentralized chattering free sliding control design in order to handle unknown bounded uncertainties, without requirements for assuming a priori knowledge of bounds on the system uncertainties as stated in conventional chattering free control methods. Subsequently, system robustness as well as stability of the decentralized full-order sliding mode control of multiple UAVs is synthesized. Numerical simulation results illustrate the effectiveness of the proposed control framework to achieve robust 3D formation flight of the multi-UAV system. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  9. Lot quality assurance sampling of sputum acid-fast bacillus smears for assessing sputum smear microscopy centers.

    PubMed

    Selvakumar, N; Murthy, B N; Prabhakaran, E; Sivagamasundari, S; Vasanthan, Samuel; Perumal, M; Govindaraju, R; Chauhan, L S; Wares, Fraser; Santha, T; Narayanan, P R

    2005-02-01

    Assessment of 12 microscopy centers in a tuberculosis unit by blinded checking of eight sputum smears selected by using a lot quality assurance sampling (LQAS) method and by unblinded checking of all positive and five negative slides, among the slides examined in a month in a microscopy centre, revealed that the LQAS method can be implemented in the field to monitor the performance of acid-fast bacillus microscopy centers in national tuberculosis control programs.

  10. Lot Quality Assurance Sampling of Sputum Acid-Fast Bacillus Smears for Assessing Sputum Smear Microscopy Centers

    PubMed Central

    Selvakumar, N.; Murthy, B. N.; Prabhakaran, E.; Sivagamasundari, S.; Vasanthan, Samuel; Perumal, M.; Govindaraju, R.; Chauhan, L. S.; Wares, Fraser; Santha, T.; Narayanan, P. R.

    2005-01-01

    Assessment of 12 microscopy centers in a tuberculosis unit by blinded checking of eight sputum smears selected by using a lot quality assurance sampling (LQAS) method and by unblinded checking of all positive and five negative slides, among the slides examined in a month in a microscopy centre, revealed that the LQAS method can be implemented in the field to monitor the performance of acid-fast bacillus microscopy centers in national tuberculosis control programs. PMID:15695704

  11. Evolution of Shock Melt Compositions in Lunar Regoliths

    NASA Technical Reports Server (NTRS)

    Vance, A. M.; Christoffersen, R.; Keller, L. P.; Berger, E. L.; Noble, S. K.

    2016-01-01

    Space weathering processes - driven primarily by solar wind ion and micrometeorite bombardment, are constantly changing the surface regoliths of airless bodies, such as the Moon. It is essential to study lunar soils in order to fully under-stand the processes of space weathering, and how they alter the optical reflectance spectral properties of the lunar surface relative to bedrock. Lunar agglutinates are aggregates of regolith grains fused together in a glassy matrix of shock melt produced during micrometeorite impacts into the lunar regolith. The formation of the shock melt component in agglutinates involves reduction of Fe in the target material to generate nm-scale spherules of metallic Fe (nanophase Fe0 or npFe0). The ratio of elemental Fe, in the form of npFe0, to FeO in a given bulk soil indicates its maturity, which increases with length of surface exposure as well as being typically higher in the finer-size fraction of soils. The melting and mixing process in agglutinate formation remain poorly understood. This includes incomplete knowledge regarding how the homogeneity and overall compositional trends of the agglutinate glass portions (agglutinitic glass) evolve with maturity. The aim of this study is to use sub-micrometer scale X-ray compositional mapping and image analysis to quantify the chemical homogeneity of agglutinitic glass, correlate its homogeneity to its parent soil maturity, and identify the principal chemical components contributing to the shock melt composition variations. An additional focus is to see if agglutinitic glass contains anomalously high Fe sub-micron scale compositional domains similar to those recently reported in glassy patina coatings on lunar rocks.

  12. On a grain of sand - a microhabitat for the opportunistic agglutinated foraminifera Hemisphaerammina apta n. sp., from the early Eocene Arctic Ocean

    NASA Astrophysics Data System (ADS)

    McNeil, David H.; Neville, Lisa A.

    2018-02-01

    Hemisphaerammina apta n. sp. is an attached monothalamous agglutinated foraminifera discovered in shelf sediments of the early Eocene Arctic Ocean. It is a simple yet distinctive component of the endemic agglutinated foraminiferal assemblage that colonized the Arctic Ocean after the microfaunal turnover caused by the Paleocene-Eocene Thermal Maximum. Associated foraminifera are characterized by a high percentage of monothalamous species (up to 60 %) and are entirely agglutinated indicating a brackish (mesohaline) early Eocene Arctic Ocean. Hemisphaerammina apta occurs exclusively as individuals attached to fine detrital grains (0.2 to 1.8 mm) of sediment. It is a small species (0.06 to 0.2 mm in diameter), fine-grained, with a low hemispherical profile, no floor across the attachment area, no substantive marginal flange, no internal structures, and no aperture. Lacking an aperture, it apparently propagated and fed through minute (micrometre-sized) interstitial pores in the test wall. Attachment surfaces vary from concave to convex and rough to smooth. Grains for attachment are diverse in shape and type but are predominantly of quartz and chert. The presence of H. apta in the early Eocene was an opportunistic response to an environment with an active hydrological system (storm events). Attachment to grains of sand would provide a more stable base on a sea floor winnowed by storm-generated currents. Active transport is indicated by the relative abundance of reworked foraminifera mixed with in situ species. Contemporaneous reworking and colonization by H. apta is suggested by its attachment to a reworked specimen of Cretaceous foraminifera.

  13. A comparison of five serological tests for bovine brucellosis.

    PubMed Central

    Dohoo, I R; Wright, P F; Ruckerbauer, G M; Samagh, B S; Robertson, F J; Forbes, L B

    1986-01-01

    Five serological assays: the buffered plate antigen test, the standard tube agglutination test, the complement fixation test, the hemolysis-in-gel test and the indirect enzyme immunoassay were diagnostically evaluated. Test data consisted of results from 1208 cattle in brucellosis-free herds, 1578 cattle in reactor herds of unknown infection status and 174 cattle from which Brucella abortus had been cultured. The complement fixation test had the highest specificity in both nonvaccinated and vaccinated cattle. The indirect enzyme immunoassay, if interpreted at a high threshold, also exhibited a high specificity in both groups of cattle. The hemolysis-in-gel test had a very high specificity when used in nonvaccinated cattle but quite a low specificity among vaccinates. With the exception of the complement fixation test, all tests had high sensitivities if interpreted at the minimum threshold. However, the sensitivities of the standard tube agglutination test and indirect enzyme immunoassay, when interpreted at high thresholds were comparable to that of the complement fixation test. A kappa statistic was used to measure the agreement between the various tests. In general the kappa statistics were quite low, suggesting that the various tests may detect different antibody isotypes. There was however, good agreement between the buffered plate antigen test and standard tube agglutination test (the two agglutination tests evaluated) and between the complement fixation test and the indirect enzyme immunoassay when interpreted at a high threshold. With the exception of the buffered plate antigen test, all tests were evaluated as confirmatory tests by estimating their specificity and sensitivity on screening-test positive samples.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:3539295

  14. Antigenic and functional characterization of p57 produced by Renibacterium salmoninarum

    USGS Publications Warehouse

    Weins, G.; Chien, M.S.; Winton, J.R.; Kaatari, S.L.

    1999-01-01

    Renibacterium salmoninarum, the causative agent of bacterial kidney disease, produces large quantities of a 57-58 kDa protein (p57) during growth in broth culture and during infection of salmonid fish. Biological activities of secreted p57 include agglutination of salrnonid leucocytes and rabbit erythrocytes. We define the location of epitopes on p57 recognized by agglutination-blocking monoclonal antibodies (MAbs) 4Cl1, 4H8 and 4D3, and demonstrate that the majority of secreted p57 is a nlonomer that retains salrnonid leucocyte agglutinat~ng activity. The 3 MAbs bound a recombinant, amino-terminal fragment of p57 (211 aa) but not a carboxy-terminal fragment (315 aa) demonstrating that the neutralizing epitopes are located within the amino-terminal portion of p57. When combinations of the MAbs were used in an antigen capture ELISA. the epitopes recognized by the 3 MAbs were shown to be sterically separate. However, when the same MAb was used as both the coating and detection MAb, binding of the biotinylated detection MAb was not observed. These data indicate that the epitopes recognized by the 3 agglutination-blocking antibodies are functionally available only once per molecule and that native p57 exists as a monomer Similar ELISA results were obtained when kidney tissues from 3 naturally infected chinook salmon were assayed. Finally, a p57 monomer was purified using anion exchange and size exclusion chromatography that retained in vitro agglutinating activity. A model in which p57 is released from R. salmoninarum as a biologically active monomer during infection of salmonid fish is proposed.

  15. Immediate Effects of Neurodynamic Sliding versus Muscle Stretching on Hamstring Flexibility in Subjects with Short Hamstring Syndrome

    PubMed Central

    Castellote-Caballero, Yolanda; Valenza, Maríe C.; Puentedura, Emilio J.; Fernández-de-las-Peñas, César; Alburquerque-Sendín, Francisco

    2014-01-01

    Background. Hamstring injuries continue to affect active individuals and although inadequate muscle extensibility remains a commonly accepted factor, little is known about the most effective method to improve flexibility. Purpose. To determine if an isolated neurodynamic sciatic sliding technique would improve hamstring flexibility to a greater degree than stretching or a placebo intervention in asymptomatic subjects with short hamstring syndrome (SHS). Study Design. Randomized double-blinded controlled trial. Methods. One hundred and twenty subjects with SHS were randomized to 1 of 3 groups: neurodynamic sliding, hamstring stretching, and placebo control. Each subject's dominant leg was measured for straight leg raise (SLR) range of motion (ROM) before and after interventions. Data were analyzed with a 3 × 2 mixed model ANOVA followed by simple main effects analyses. Results. At the end of the study, more ROM was observed in the Neurodynamic and Stretching groups compared to the Control group and more ROM in the Neurodynamic group compared to Stretching group. Conclusion. Findings suggest that a neurodynamic sliding technique will increase hamstring flexibility to a greater degree than static hamstring stretching in healthy subjects with SHS. Clinical Relevance. The use of neurodynamic sliding techniques to improve hamstring flexibility in sports may lead to a decreased incidence in injuries; however, this needs to be formally tested. PMID:26464889

  16. Using a visual discrimination model for the detection of compression artifacts in virtual pathology images.

    PubMed

    Johnson, Jeffrey P; Krupinski, Elizabeth A; Yan, Michelle; Roehrig, Hans; Graham, Anna R; Weinstein, Ronald S

    2011-02-01

    A major issue in telepathology is the extremely large and growing size of digitized "virtual" slides, which can require several gigabytes of storage and cause significant delays in data transmission for remote image interpretation and interactive visualization by pathologists. Compression can reduce this massive amount of virtual slide data, but reversible (lossless) methods limit data reduction to less than 50%, while lossy compression can degrade image quality and diagnostic accuracy. "Visually lossless" compression offers the potential for using higher compression levels without noticeable artifacts, but requires a rate-control strategy that adapts to image content and loss visibility. We investigated the utility of a visual discrimination model (VDM) and other distortion metrics for predicting JPEG 2000 bit rates corresponding to visually lossless compression of virtual slides for breast biopsy specimens. Threshold bit rates were determined experimentally with human observers for a variety of tissue regions cropped from virtual slides. For test images compressed to their visually lossless thresholds, just-noticeable difference (JND) metrics computed by the VDM were nearly constant at the 95th percentile level or higher, and were significantly less variable than peak signal-to-noise ratio (PSNR) and structural similarity (SSIM) metrics. Our results suggest that VDM metrics could be used to guide the compression of virtual slides to achieve visually lossless compression while providing 5-12 times the data reduction of reversible methods.

  17. Investigation of transient temperature's influence on damage of high-speed sliding electrical contact rail surface

    NASA Astrophysics Data System (ADS)

    Zhang, Yuyan; Sun, Shasha; Guo, Quanli; Yang, Degong; Sun, Dongtao

    2016-11-01

    In the high speed sliding electrical contact with large current, the temperature of contact area rises quickly under the coupling action of the friction heating, the Joule heating and electric arc heating. The rising temperature seriously affects the conductivity of the components and the yield strength of materials, as well affects the contact state and lead to damage, so as to shorten the service life of the contact elements. Therefore, there is vital significance to measure the temperature accurately and investigate the temperature effect on damage of rail surface. Aiming at the problem of components damage in high speed sliding electrical contact, the transient heat effect on the contact surface was explored and its influence and regularity on the sliding components damage was obtained. A kind of real-time temperature measurement method on rail surface of high speed sliding electrical contact is proposed. Under the condition of 2.5 kA current load, based on the principle of infrared radiation non-contact temperature sensor was used to measure the rail temperature. The dynamic distribution of temperature field was obtained through the simulation analysis, further, the connection between temperature changes and the rail surface damage morphology, the damage volume was analyzed and established. Finally, the method to reduce rail damage and improve the life of components by changing the temperature field was discussed.

  18. Applications and challenges of digital pathology and whole slide imaging.

    PubMed

    Higgins, C

    2015-07-01

    Virtual microscopy is a method for digitizing images of tissue on glass slides and using a computer to view, navigate, change magnification, focus and mark areas of interest. Virtual microscope systems (also called digital pathology or whole slide imaging systems) offer several advantages for biological scientists who use slides as part of their general, pharmaceutical, biotechnology or clinical research. The systems usually are based on one of two methodologies: area scanning or line scanning. Virtual microscope systems enable automatic sample detection, virtual-Z acquisition and creation of focal maps. Virtual slides are layered with multiple resolutions at each location, including the highest resolution needed to allow more detailed review of specific regions of interest. Scans may be acquired at 2, 10, 20, 40, 60 and 100 × or a combination of magnifications to highlight important detail. Digital microscopy starts when a slide collection is put into an automated or manual scanning system. The original slides are archived, then a server allows users to review multilayer digital images of the captured slides either by a closed network or by the internet. One challenge for adopting the technology is the lack of a universally accepted file format for virtual slides. Additional challenges include maintaining focus in an uneven sample, detecting specimens accurately, maximizing color fidelity with optimal brightness and contrast, optimizing resolution and keeping the images artifact-free. There are several manufacturers in the field and each has not only its own approach to these issues, but also its own image analysis software, which provides many options for users to enhance the speed, quality and accuracy of their process through virtual microscopy. Virtual microscope systems are widely used and are trusted to provide high quality solutions for teleconsultation, education, quality control, archiving, veterinary medicine, research and other fields.

  19. Non-typhoidal Salmonella serotypes, antimicrobial resistance and co-infection with parasites among patients with diarrhea and other gastrointestinal complaints in Addis Ababa, Ethiopia.

    PubMed

    Eguale, Tadesse; Gebreyes, Wondwossen A; Asrat, Daniel; Alemayehu, Haile; Gunn, John S; Engidawork, Ephrem

    2015-11-04

    Non-typhoidal Salmonella (NTS) is an important public health problem worldwide. Consumption of animal-derived food products and direct and/or indirect contact with animals are the major routes of acquiring infection with NTS. Published information, particularly on the serotype distribution of NTS among human patients with gastroenteritis and associated risk factors, is scarce in Ethiopia. This study investigated the prevalence, risk factors, serotype distribution and antimicrobial susceptibility of Salmonella species among diarrheic out-patients attending health centers in Addis Ababa and patients with various gastrointestinal complaints at Tikur Anbessa Specialized Hospital (TASH). Stool samples were cultured for Salmonella species according to the WHO Global Foodborne Infections Network laboratory protocol. Salmonella serotyping was conducted using slide agglutination and microplate agglutination techniques. Antibiotic susceptibility testing was performed using the disk diffusion method according to Clinical and Laboratory Standards Institute guidelines. A total of 59 (6.2 %) stool samples, out of 957 were culture positive for Salmonella species. Fifty-five (7.2 %) of 765 diarrheic patients from health centers and 4 (2.1 %) of 192 patients from TASH were culture positive for Salmonella species. Multivariable logistic regression analysis after adjusting for all other variables revealed statistically significant association of Salmonella infection with consumption of raw vegetables (OR = 1.91, 95 % CI = 1.29-2.83, χ(2) = 4.74, p = 0.025) and symptom of watery diarrhea (OR = 3.3, 95 % CI = 1.23-8.88, χ(2) = 10.54, p = 0.005). Eleven serotypes were detected, and the most prominent were S. Typhimurium (37.3 %), S. Virchow (34 %), and S. Kottbus (10.2 %). Other serotypes were S. Miami, S. Kentucky, S. Newport, S. Enteritidis, S. Braenderup, S. Saintpaul, S. Concord and S. V:ROUGH-O. Resistance to three or more antimicrobials was detected in 27 (40.3 %) of the isolates. Resistance to five or more antimicrobials was detected in 17 (25.4 %). Resistance to individual antimicrobials was found at varying proportions: streptomycin (50; 74.6 %), nitrofurantoin (27; 40.3 %), sulfisoxazole (26; 38.8 %), kanamycin (23; 34.3 %), cephalothin (12; 17.9 %), and ampicillin (11; 16.4 %) respectively. Two S. Kentucky, one S. Typhimurium and one S. Concord isolates were multi-drug resistant to more than 10 antimicrobials. The study demonstrated significant association of Salmonella infection with consumption of raw vegetables. There was no significant association of Salmonella infection with co-occurring parasites. The study also showed the dominance of S. Typhimurium and S. Virchow in primary health care units. Overall, prevalence of MDR was low compared to previous studies. Although their proportion was low, S. Kentucky and S. Concord demonstrated wider spectrum of MDR. Continuous monitoring of circulating serotypes, antimicrobial resistance profile and characterization on molecular resistance determinants is essential for proper treatment of patients and for identifying potential environmental origins of antimicrobial resistance.

  20. Sliding mode control for a two-joint coupling nonlinear system based on extended state observer.

    PubMed

    Zhao, Ling; Cheng, Haiyan; Wang, Tao

    2018-02-01

    A two-joint coupling nonlinear system driven by pneumatic artificial muscles is introduced in this paper. A sliding mode controller with extended state observer is proposed to cope with nonlinearities and disturbances for the two-joint coupling nonlinear system. In addition, convergence of the extended state observer is presented and stability analysis of the closed-loop system is also demonstrated with the sliding mode controller. Lastly, some experiments are carried out to show the reality effectiveness of the proposed method. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

Top