NASA Technical Reports Server (NTRS)
Anderson, David T.; Davis, Scott; Zwier, Timothy S.; Nesbitt, David J.
1996-01-01
A novel pulsed, slit supersonic discharge source is described for generating intense jet-cooled densities of radicals (greater than 10(exp 12)/cu cm) and molecular ions (greater than 10(exp 10)/cu cm) under long absorption path (80 cm), supersonically cooled conditions. The design confines the discharge region upstream of the supersonic expansion orifice to achieve efficient rotational cooling down to 30 K or less. The collisionally collimated velocity distribution in the slit discharge geometry yields sub-Doppler spectral linewidths, which for open-shell radicals reveals spin-rotation splittings and broadening due to nuclear hyperfine structure. Application of the slit source for high-resolution, direct IR laser absorption spectroscopy in discharges is demonstrated on species such as OH, H3O(+) and N2H(+).
Plasma in a Pulsed Discharge Environment
NASA Technical Reports Server (NTRS)
Remy, J.; Bienier, L.; Salama, F.
2005-01-01
The plasma generated in a pulsed slit discharge nozzle is used to form molecular ions in an astrophysically relevant environment. The plasma has been characterized as a glow discharge in the abnormal regime. Laboratory studies help understand the formation processes of polycyclic aromatic hydrocarbon (PAH) ions that are thought to be the source of the ubiquitous unidentified infrared bands.
Clark, A.F.
1959-06-16
A means of eliminating oscillating electrons from the arc slit region of calutron ion sources is offered. Free electrons and ions generated by the beam bombarding atoms of ambient atmosphere are discharged by a fin arrangement which sets up an electric field. The discharged ions travel toward a recess in which a fin and blister'' effect limits oscillations to one region from which they are removed by reversed electric fields. (T.R.H.)
Radiation source with shaped emission
Kubiak, Glenn D.; Sweatt, William C.
2003-05-13
Employing a source of radiation, such as an electric discharge source, that is equipped with a capillary region configured into some predetermined shape, such as an arc or slit, can significantly improve the amount of flux delivered to the lithographic wafers while maintaining high efficiency. The source is particularly suited for photolithography systems that employs a ringfield camera. The invention permits the condenser which delivers critical illumination to the reticle to be simplified from five or more reflective elements to a total of three or four reflective elements thereby increasing condenser efficiency. It maximizes the flux delivered and maintains a high coupling efficiency. This architecture couples EUV radiation from the discharge source into a ring field lithography camera.
A Penning discharge source for extreme ultraviolet calibration
NASA Technical Reports Server (NTRS)
Finley, David S.; Jelinsky, Patrick; Bowyer, Stuart; Malina, Roger F.
1986-01-01
A Penning discharge lamp for use in the calibration of instruments and components for the extreme ultraviolet has been developed. This source is sufficiently light and compact to make it suitable for mounting on the movable slit assembly of a grazing incidence Rowland circle monochromator. Because this is a continuous discharge source, it is suitable for use with photon counting detectors. Line radiation is provided both by the gas and by atoms sputtered off the interchangeable metal cathodes. Usable lines are produced by species as highly ionized as Ne IV and Al V. The wavelength coverage provided is such that a good density of emission lines is available down to wavelengths as short as 100A. This source fills the gap between 100 and 300A, which is inadequately covered by the other available compact continuous radiation sources.
APPARATUS FOR PRODUCING IONS OF VAPORIZABLE MATERIALS
Starr, C.
1957-11-19
This patent relates to electronic discharge devices used as ion sources, and in particular describes an ion source for application in a calutron. The source utilizes two cathodes disposed at opposite ends of a longitudinal opening in an arc block fed with vaporized material. A magnetic field is provided parallel to the length of the arc block opening. The electrons from the cathodes are directed through slits in collimating electrodes into the arc block parallel to the magnetic field and cause an arc discharge to occur between the cathodes, as the arc block and collimating electrodes are at a positive potential with respect to the cathode. The ions are withdrawn by suitable electrodes disposed opposite the arc block opening. When such an ion source is used in a calutron, an arc discharge of increased length may be utilized, thereby increasing the efficiency and economy of operation.
NASA Astrophysics Data System (ADS)
Li, Xuechen; Chu, Jingdi; Zhang, Qi; Zhang, Panpan; Jia, Pengying; Dong, Lifang
2018-04-01
A diffuse argon plume at atmospheric pressure is generated downstream of a longitudinal slit jet equipped with a dielectric barrier discharge in a quadri-electrode configuration. Results indicate that both the plume length and the spectral line intensities increase with the increase in the peak voltage. With fast photography it is found that there is a clear difference for discharges with different polarities. The positive discharge is composed of nonuniform branching filaments; however, it is fairly uniform for the negative discharge. Due to the charge overflow of the intra-electrode discharge, the streamer mechanism is involved in the plume discharge. In fact, the positive discharge and the negative one correspond to a cathode-directed streamer and an anode-directed streamer, respectively. The formation mechanisms of the branching filaments and the diffuse background are discussed at last.
On-site SiH4 generator using hydrogen plasma generated in slit-type narrow gap
NASA Astrophysics Data System (ADS)
Takei, Norihisa; Shinoda, Fumiya; Kakiuchi, Hiroaki; Yasutake, Kiyoshi; Ohmi, Hiromasa
2018-06-01
We have been developing an on-site silane (SiH4) generator based on use of the chemical etching reaction between solid silicon (Si) and the high-density H atoms that are generated in high-pressure H2 plasma. In this study, we have developed a slit-type plasma source for high-efficiency SiH4 generation. High-density H2 plasma was generated in a narrow slit-type discharge gap using a 2.45 GHz microwave power supply. The plasma’s optical emission intensity distribution along the slit was measured and the resulting distribution was reflected by both the electric power distribution and the hydrogen gas flow. Because the Si etching rate strongly affects the SiH4 generation rate, the Si etching behavior was investigated with respect to variations in the experimental parameters. The weight etch rate increased monotonically with increasing input microwave power. However, the weight etch rate decreased with increasing H2 pressure and an increasing plasma gap. This reduction in the etch rate appears to be related to shrinkage of the plasma generation area because increased input power is required to maintain a constant plasma area with increasing H2 pressure and the increasing plasma gap. Additionally, the weight etch rate also increases with increasing H2 flow rate. The SiH4 generation rate of the slit-type plasma source was also evaluated using gas-phase Fourier transform infrared absorption spectroscopy and the material utilization efficiencies of both Si and the H2 gas for SiH4 gas formation were discussed. The main etch product was determined to be SiH4 and the developed plasma source achieved a SiH4 generation rate of 10 sccm (standard cubic centimeters per minute) at an input power of 900 W. In addition, the Si utilization efficiency exceeded 60%.
Backus, J.G.
1957-12-24
This patent relates to ion sources and more particularly describes an ion source for a calutron which has the advantage of efficient production of an ion beam and long operation time without recharging. The source comprises an arc block provided with an arc chamber connected to a plurality of series-connected charge chambers and means for heating the charge within the chambers. A cathode is disposed at one end of the arc chamber and enclosed hy a vapor tight housing to protect the cathode. The arc discharge is set up between the cathode and the block due to a difference in potentials placed on these parts, and a magnetic field is aligned with the arc discharge. Cooling of the arc block is accomplished by passing coolant through a hollow stem secured at one end to the block and rotatably mounted at the other end through the wall of the calutron. The ions are removed through a slit in the arc chamber by accelerating electrodes.
Sillito, A. M.
1977-01-01
1. An investigation has been made of the extent of inhibitory and excitatory components in the receptive field of superficial layer hypercomplex cells in the cat's striate cortex and the relation of the components to the length preference exhibited by these cells. 2. Maximal responses were produced by an optimal length stimulus moving through a restricted region of the receptive field. The length of this receptive field region was less than the total length of the excitatory zone as mapped with a very short slit. Slits of similar length to the excitatory zone produced a smaller response than an optimal length slit. 3. An increase of slit length so that it passed over receptive field regions either side of the excitatory zone resulted in an elimination of the response. When background discharge levels were increased by the iontophoretic application of D, L-homocysteic acid slits of this length were observed to produce a suppression of the resting discharge as they passed over the receptive field. They did not modify the resting discharge level when it was induced by the iontophoretic application of the GABA antagonist bicuculline. This data is taken to indicate that long slits activate a powerful post-synaptic inhibitory input to the cell. 4. Maximal inhibitory effects were only observed if the testing slit passed over the receptive field centre. That is slits with a gap positioned midway along their length so as to exclude the optimal excitatory response region surprisingly tended to produce excitatory effects rather than the expected inhibitory effects. It appears that simultaneous stimulation of the receptive field centre is a precondition for the inhibitory effect of stimulation of regions either side of the excitatory zone to be activated. 5. It is suggested that the interneurones mediating the inhibitory input to the superficial layer hypercomplex cells are driven both by cells in adjacent hypercolumns with receptive fields spatially displaced to either side of the excitatory zone and by cells in the same column, optimal inhibitory effects only being achieved when both sets of input to the interneurone are activated. PMID:604459
Jhanji, Vishal; Yang, Bingzhi; Yu, Marco; Ye, Cong; Leung, Christopher K S
2013-11-01
To compare corneal thickness and corneal elevation using swept source optical coherence tomography and slit scanning topography. Prospective study. 41 normal and 46 keratoconus subjects. All eyes were imaged using swept source optical coherence tomography and slit scanning tomography during the same visit. Mean corneal thickness and best-fit sphere measurements were compared between the instruments. Agreement of measurements between swept source optical coherence tomography and scanning slit topography was analyzed. Intra-rater reproducibility coefficient and intraclass correlation coefficient were evaluated. In normal eyes, central corneal thickness measured by swept source optical coherence tomography was thinner compared with slit scanning topography (p < 0.0001) and ultrasound pachymetry (p = < .0001). Ultrasound pachymetry readings had better 95% limits of agreement with swept source optical coherence tomography than slit scanning topography. In keratoconus eyes, central corneal thickness was thinner on swept source optical coherence tomography than slit scanning topography (p = 0.081) and ultrasound pachymetry (p = 0.001). There were significant differences between thinnest corneal thickness, and, anterior and posterior best-fit sphere measurements between both instruments (p < 0.05 for all). Overall, reproducibility coefficients and intraclass correlation coefficients were significantly better with swept source optical coherence tomography for measurement of central corneal thickness, anterior best-fit sphere and, posterior best-fit sphere (all p < 0.001). Corneal thickness and elevation measurements were significantly different between swept source optical coherence tomography and slit scanning topography. With better reproducibility coefficients and intraclass correlation coefficients, swept source optical coherence tomography may provide a reliable alternative for measurement of corneal parameters. © 2013 The Authors. Clinical and Experimental Ophthalmology © 2013 Royal Australian and New Zealand College of Ophthalmologists.
A Planar Source of Atmospheric-Pressure Plasma Jet
NASA Astrophysics Data System (ADS)
Zhdanova, O. S.; Kuznetsov, V. S.; Panarin, V. A.; Skakun, V. S.; Sosnin, E. A.; Tarasenko, V. F.
2018-01-01
In a single-barrier discharge with voltage sharpening and low gas consumption (up to 1 L/min), plane atmospheric pressure plasma jets with a width of up to 3 cm and length of up to 4 cm in air are formed in the slit geometry of the discharge zone. The energy, temperature, and spectral characteristics of the obtained jets have been measured. The radiation spectrum contains intense maxima corresponding to vibrational transitions of the second positive system of molecular nitrogen N2 ( C 3Π u → B 3Π g ) and comparatively weak transition lines of the first positive system of the N 2 + ion ( B 2Σ u + → X 2Σ g ). By an example of inactivation of the Staphylococcus aureus culture (strain ATCC 209), it is shown that plasma is a source of chemically active particles providing the inactivation of microorganisms.
Goto, Tomoaki; Shiba, Yojiro; Shibagaki, Kazuhiro; Nakaya, Kazuhiro
2013-06-01
We examined gill morphology and ventilatory function in the carpet shark family Parascylliidae using 14 preserved specimens of Parascyllium ferrugineum, P. variolatum, P. collare and Cirrhoscyllium japonicum, and two live specimens of P. ferrugineum and P. variolatum. Morphological examinations revealed eight morphological characteristics related to the fifth gill, based on comparisons with other elasmobranchs, viz. large fifth gill slit without gill filaments, anatomical modifications in the fourth ceratobranchial cartilage and coraco-branchialis muscle, and the hypaxialis muscle associated with the fifth gill arch. Ventilation examinations using dyed seawater and prey items showed different water flows through the gill slits for respiration and prey-capture actions. For respiration, water sucked into the mouth was expelled equally through the first to fourth gill slits via a "double-pump" action, there being no involvement of the fifth gill slit. In prey-capture, however, water sucked into the mouth was discharged only via the widely opened fifth gill slit. This form of water flow is similar to that in other benthic suction-feeding sharks (e.g., Chiloscyllium plagiosum), except for the active water discharge by wide expansion and contraction of the fifth parabranchial cavity. The latter is dependent upon the morphological modifications of the fourth and fifth gill arches, derived phylogenetically as a mechanistic suction specialization in Parascylliidae.
Measurements of the cesium flow from a surface-plasma H/sup -/ ion source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, H.V.; Allison, P.W.
1979-01-01
A surface ionization gauge (SIG) was constructed and used to measure the Cs/sup 0/ flow rate through the emission slit of a surface-plasma source (SPS) of H/sup -/ ions with Penning geometry. The equivalent cesium density in the SPS discharge is deduced from these flow measurements. For dc operation the optimum H/sup -/ current occurs at an equivalent cesium density of approx. 7 x 10/sup 12/ cm/sup -3/ (corresponding to an average cesium consumption rate of 0.5 mg/h). For pulsed operation the optimum H/sup -/ current occurs at an equivalent cesium density of approx. 2 x 10/sup 13/ cm/sup -3/more » (1-mg/h average cesium consumption rate). Cesium trapping by the SPS discharge was observed for both dc and pulsed operation. A cesium energy of approx. 0.1 eV is deduced from the observed time of flight to the SIG. In addition to providing information on the physics of the source, the SIG is a useful diagnostic tool for source startup and operation.« less
VizieR Online Data Catalog: Gas-phase detection of c-C3H3
NASA Astrophysics Data System (ADS)
Zhao, D.; Doney, K. D.; Linnartz, H.
2017-03-01
The experimental setup has been described in detail by Zhao et al. (2013CPL...565..132Z, 2014JMoSp.296....1Z). In brief, the c-C3H3+ cations are generated by discharging a propyne (C3H4):He ~ 1:200 gas mixture in a multi-layer slit discharge nozzle (Motylewski & Linnartz 1999RScI...70.1305M) in combination with a pulsed valve (General Valve, Series 9,2 mm orifice). The gas mixture is expanded with a backing pressure of ~7 bar through a 300umx3cm slit into a vacuum chamber. A pulsed negative high voltage (-600 V/300 mA) with a ~600 us duration is found to be optimum for c-C3H3+ production, is applied to the expanding gas mixture, and is set to coincide with the expanding gas pulse (~800 us). Continuous-wave cavity ring-down spectroscopy (cw-CRDS) is used to record spectra in direct absorption. The axis of the optical cavity is aligned parallel to and ~2 mm downstream of the slit nozzle throat. A single-mode cw optical parametric oscillator (Aculight), operating at ~3.15 um with a bandwidth <5x10-5cm-1, is employed as tunable IR light source. A hardware-based (boxcar integrator) multi-trigger and timing scheme recently reported by Zhao et al. (2013CPL...565..132Z) is used to apply cw-CRDS to the pulsed plasma. In the present experiment, typical ring-down time values are ~8-10 us, corresponding to a detection sensitivity, i.e., noise equivalent absorption, of up to ~2x10-7 per centimeter for the 3 cm long plasma jet. (1 data file).
Low energy, high power hydrogen neutral beam for plasma heating
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deichuli, P.; Davydenko, V.; Ivanov, A., E-mail: ivanov@inp.nsk.su
A high power, relatively low energy neutral beam injector was developed to upgrade of the neutral beam system of the gas dynamic trap device and C2-U experiment. The ion source of the injector produces a proton beam with the particle energy of 15 keV, current of up to 175 A, and pulse duration of a few milliseconds. The plasma emitter of the ion source is produced by superimposing highly ionized plasma jets from an array of four arc-discharge plasma generators. A multipole magnetic field produced with permanent magnets at the periphery of the plasma box is used to increase themore » efficiency and improve the uniformity of the plasma emitter. Multi-slit grids with 48% transparency are fabricated from bronze plates, which are spherically shaped to provide geometrical beam focusing. The focal length of the Ion Optical System (IOS) is 3.5 m and the initial beam diameter is 34 cm. The IOS geometry and grid potentials were optimized numerically to ensure accurate beam formation. The measured angular divergences of the beam are ±0.01 rad parallel to the slits and ±0.03 rad in the transverse direction.« less
Spatial Structure in the Infrared Spectra of Three Evolved Stars
NASA Astrophysics Data System (ADS)
Sloan, G. C.; Tandy, P. C.; Pirger, B. E.; Hodge, T. M.
1993-05-01
We have spatially resolved three evolved sources using GLADYS, a long-slit 10 microns spectrometer, at the Wyoming Infrared Observatory. These observations, made in 1993 March, were the first for GLADYS after a complete replacement of the detector drive electronics, ADCs, and hardware co-adder. We studied each source in a north/south and an east/west slit orientation. For each set of observations, we fit a gaussian to the spatial profile at each wavelength to create a spatiogram, or plot of the width of the spectrum as a function of wavelength. In both slit orientations, the spatiogram of alpha Orionis is widest at 10 microns, where the contribution from the silicate dust in the circumstellar shell is strongest. The FWHM at 10 microns is 2.0 arcsec, while our point-source comparison has a FWHM of 1.6 arcsec. These results are very similar to those presented for a N/S slit by Grasdalen, Sloan, and LeVan (1992, ApJ, 384, L25). IRC+10216 is also resolved in both slit orientations, having a FWHM of 1.9 arcsec at 11 microns, compared with 1.5 arcsec for a point source. No spectral structure is apparent in the spatiograms, indicating that there is little change in the spectral character of the emission across the source. AFGL 2688 (the Cygnus Egg) is clearly resolved in the N/S slit orientation, where its FWHM at 11 microns is 2.2 arcsec, but its spatiogram in the E/W slit orientation is barely distinguishable from that of a point source.
Sediment trapping efficiency of adjustable check dam in laboratory and field experiment
NASA Astrophysics Data System (ADS)
Wang, Chiang; Chen, Su-Chin; Lu, Sheng-Jui
2014-05-01
Check dam has been constructed at mountain area to block debris flow, but has been filled after several events and lose its function of trapping. For the reason, the main facilities of our research is the adjustable steel slit check dam, which with the advantages of fast building, easy to remove or adjust it function. When we can remove transverse beams to drain sediments off and keep the channel continuity. We constructed adjustable steel slit check dam on the Landow torrent, Huisun Experiment Forest station as the prototype to compare with model in laboratory. In laboratory experiments, the Froude number similarity was used to design the dam model. The main comparisons focused on types of sediment trapping and removing, sediment discharge, and trapping rate of slit check dam. In different types of removing transverse beam showed different kind of sediment removal and differences on rate of sediment removing, removing rate, and particle size distribution. The sediment discharge in check dam with beams is about 40%~80% of check dam without beams. Furthermore, the spacing of beams is considerable factor to the sediment discharge. In field experiment, this research uses time-lapse photography to record the adjustable steel slit check dam on the Landow torrent. The typhoon Soulik made rainfall amounts of 600 mm in eight hours and induced debris flow in Landow torrent. Image data of time-lapse photography demonstrated that after several sediment transport event the adjustable steel slit check dam was buried by debris flow. The result of lab and field experiments: (1)Adjustable check dam could trap boulders and stop woody debris flow and flush out fine sediment to supply the need of downstream river. (2)The efficiency of sediment trapping in adjustable check dam with transverse beams was significantly improved. (3)The check dam without transverse beams can remove the sediment and keep the ecosystem continuity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Benson, C.; Jaski, Y.; Powers, T.
2007-01-19
A new type of slit has been designed for use in the hard x-ray nanoprobe beamline at the Advanced Photon Source (APS). The design incorporates monolithic GlidCop slit bodies mounted to commercially available x-y drive systems. Long, tapered apertures with adjacent water-cooling channels intercept the x-ray beam, removing the high heat load produced by two collinear APS undulators. The apertures are L-shaped and provide both horizontal and vertical slits. The beam-defining edges, positioned at the end of the tapered surfaces, consist of two sets of tungsten blades. These blades produce an exit beam with sharp corners and assure a cleanmore » cut-off for the white beam edges. The slit assembly is designed to allow overlap of the slit edges to stop the beam.The white beam slit design accommodates 3100 W of total power with a peak power density of 763 W/mm2. The pink beam slit design accommodates 400 W of total power with a peak power density of 180 W/mm2. Detailed thermal analyses were performed to verify the slits' accuracy under full beam loading. The new concept allows beamline operations to 180 mA with a simplified design approach.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Benson, C.; Jaski, Y.; Maser, J.
2007-01-01
A new type of slit has been designed for use in the hard x-ray nanoprobe beamline at the Advanced Photon Source (APS). The design incorporates monolithic GlidCop slit bodies mounted to commercially available x-y drive systems. Long, tapered apertures with adjacent water-cooling channels intercept the x-ray beam, removing the high heat load produced by two collinear APS undulators. The apertures are L-shaped and provide both horizontal and vertical slits. The beam-defining edges, positioned at the end of the tapered surfaces, consist of two sets of tungsten blades. These blades produce an exit beam with sharp corners and assure a cleanmore » cut-off for the white beam edges. The slit assembly is designed to allow overlap of the slit edges to stop the beam. The white beam slit design accommodates 3100 W of total power with a peak power density of 763 W/mm2. The pink beam slit design accommodates 400 W of total power with a peak power density of 180 W/mm2. Detailed thermal analyses were performed to verify the slits accuracy under full beam loading. The new concept allows beamline operations to 180 mA with a simplified design approach.« less
A gas discharge lamp for the extreme ultraviolet.
Nicholson, A J
1970-05-01
A gas discharge lamp is described suitable for producing the many-lined spectrum of hydrogen (85-160 nm) and the Hopfield continuum in helium (60-100 nm). It was designed for use with a window-less monochromator to study photoionization and operates at pressures below 50 Torr. The hydrogen lamp has a mode of operation which concentrates the discharge into the monochromator entrance slit.
NASA Astrophysics Data System (ADS)
Kortyna, A.; Lesko, D. M. B.; Nesbitt, D. J.
2018-05-01
The combination of a pulsed supersonic slit-discharge source and single-mode difference frequency direct absorption infrared spectroscopy permit first high resolution infrared study of the iodomethyl (CH2I) radical, with the CH2I radical species generated in a slit jet Ne/He discharge and cooled to 16 K in the supersonic expansion. Dual laser beam detection and collisional collimation in the slit expansion yield sub-Doppler linewidths (60 MHz), an absolute frequency calibration of 13 MHz, and absorbance sensitivities within a factor of two of the shot-noise limit. Fully rovibrationally resolved direct absorption spectra of the CH2 symmetric stretch mode (ν2) are obtained and fitted to a Watson asymmetric top Hamiltonian with electron spin-rotation coupling, providing precision rotational constants and spin-rotation tensor elements for the vibrationally excited state. Analysis of the asymmetric top rotational constants confirms a vibrationally averaged planar geometry in both the ground- and first-excited vibrational levels. Sub-Doppler resolution permits additional nuclear spin hyperfine structures to be observed, with splittings in excellent agreement with microwave measurements on the ground state. Spectroscopic data on CH2I facilitate systematic comparison with previous studies of halogen-substituted methyl radicals, with the periodic trends strongly correlated with the electronegativity of the halogen atom. Interestingly, we do not observe any asymmetric CH2 stretch transitions, despite S/N ≈ 25:1 on strongest lines in the corresponding symmetric CH2 stretch manifold. This dramatic reversal of the more typical 3:1 antisymmetric/symmetric CH2 stretch intensity ratio signals a vibrational transition moment poorly described by simple "bond-dipole" models. Instead, the data suggest that this anomalous intensity ratio arises from "charge sloshing" dynamics in the highly polar carbon-iodine bond, as supported by ab initio electron differential density plots and indeed consistent with observations in other halomethyl radicals and protonated cluster ions.
Sinsheimer, John; Bouet, Nathalie; Ghose, Sanjit; ...
2016-10-06
A new system of slits called `spiderweb slits' have been developed for depth-resolved powder or polycrystalline X-ray diffraction measurements. The slits act on diffracted X-rays to select a particular gauge volume of sample, while absorbing diffracted X-rays from outside of this volume. Although the slit geometry is to some extent similar to that of previously developed conical slits or spiral slits, this new design has advantages over the previous ones in use for complex heterogeneous materials and in situ and operando diffraction measurements. For example, the slits can measure a majority of any diffraction cone for any polycrystalline material, overmore » a continuous range of diffraction angles, and work for X-ray energies of tens to hundreds of kiloelectronvolts. In addition, the design is generated and optimized using ray-tracing simulations, and fabricated through laser micromachining. The first prototype was successfully tested at the X17A beamline at the National Synchrotron Light Source, and shows similar performance to simulations, demonstrating gauge volume selection for standard powders, for all diffraction peaks over angles of 2–10°. A similar, but improved, design will be implemented at the X-ray Powder Diffraction beamline at the National Synchrotron Light Source II.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sinsheimer, John; Bouet, Nathalie; Ghose, Sanjit
2016-10-06
A new system of slits called `spiderweb slits' have been developed for depth-resolved powder or polycrystalline X-ray diffraction measurements. The slits act on diffracted X-rays to select a particular gauge volume of sample, while absorbing diffracted X-rays from outside of this volume. Although the slit geometry is to some extent similar to that of previously developed conical slits or spiral slits, this new design has advantages over the previous ones in use for complex heterogeneous materials andin situandoperandodiffraction measurements. For example, the slits can measure a majority of any diffraction cone for any polycrystalline material, over a continuous range ofmore » diffraction angles, and work for X-ray energies of tens to hundreds of kiloelectronvolts. The design is generated and optimized using ray-tracing simulations, and fabricated through laser micromachining. The first prototype was successfully tested at the X17A beamline at the National Synchrotron Light Source, and shows similar performance to simulations, demonstrating gauge volume selection for standard powders, for all diffraction peaks over angles of 2–10°. A similar, but improved, design will be implemented at the X-ray Powder Diffraction beamline at the National Synchrotron Light Source II.« less
NASA Astrophysics Data System (ADS)
Chang, Chih-Hsuan; Nesbitt, David J.
2018-01-01
Sub-Doppler infrared rovibrational transitions in the symmetric (v1) and antisymmetric (v6) NH stretch modes of the isotopomerically substituted ND2H2+ ammonium cation are reported for the first time in a slit jet discharge supersonic expansion spectrometer. The partially H/D substituted cation is generated by selective isotopic exchange of ND3 with H2O to form NHD2, followed by protonation with H3+ formed in the NHD2/H2/Ne slit-jet discharge expansion environment. Rotational assignment for ND2H2+ is confirmed rigorously by four line ground state combination differences, which agree to be within the sub-Doppler precision in the slit jet (˜9 MHz). Observation of both b-type (ν1) and c-type (ν6) bands enables high precision determination of the ground and vibrationally excited state rotational constants. From an asymmetric top Watson Hamiltonian analysis, the ground state constants are found to be A″ = 4.856 75(4) cm-1, B″ = 3.968 29(4) cm-1, and C″ = 3.446 67(6) cm-1, with band origins at 3297.5440(1) and 3337.9050(1) cm-1 for the v1 and v6 modes, respectively. This work permits prediction of precision microwave/mm-wave transitions, which should be invaluable in facilitating ongoing spectroscopic searches for partially deuterated ammonium cations in interstellar clouds and star-forming regions of the interstellar medium.
Ion source for high-precision mass spectrometry
Todd, Peter J.; McKown, Henry S.; Smith, David H.
1984-01-01
The invention is directed to a method for increasing the precision of positive-ion relative abundance measurements conducted in a sector mass spectrometer having an ion source for directing a beam of positive ions onto a collimating slit. The method comprises incorporating in the source an electrostatic lens assembly for providing a positive-ion beam of circular cross section for collimation by the slit.
Retrocausation acting in the single-electron double-slit interference experiment
NASA Astrophysics Data System (ADS)
Hokkyo, Noboru
The single electron double-slit interference experiment is given a time-symmetric interpretation and visualization in terms of the intermediate amplitude of transition between the particle source and the detection point. It is seen that the retarded (causal) amplitude of the electron wave expanding from the source shows an advanced (retrocausal) bifurcation and merging in passing through the double-slit and converges towards the detection point as if guided by the advanced (retrocausal) wave from the detected electron. An experiment is proposed to confirm the causation-retrocausation symmetry of the electron behavior by observing the insensitivity of the interference pattern to non-magnetic obstacles placed in the shadows of the retarded and advanced waves appearing on the rear and front sides of the double-slit.
Analysis of transmission through slit and multiple grooves structures for biosensors
NASA Astrophysics Data System (ADS)
Kim, Bong Ho; Nakarmi, Bikash; Won, Yong Hyub
2015-03-01
We analyze the transmission property of nanostructures made on silver and gold metal for the applications in optical biosensors. Various structures such as slit only, slit groove slit, and multiple slit and groove structures are taken into account to find the effect of various physical parameters such as number of grooves, number of slits and others on the transmission of different wavelength light sources through the structure. A broad wavelength of 400 nm to 900 nm is used to analyze the transmission through the structure. With these structures and broad light source, change in transmission intensity is analyzed with the change in the refractive index. The change in refractive index of the analyte varies transmission intensity and wavelength shift at the output beam which can be used for sensing the amount of analyte such as monitoring glucose amount on blood/saliva, hydrogen peroxide and others. The detection of these analytes can be used to detect the different disease. The analysis of the transmittance through the nanostructure can be used for the detection of several disease such as diabetes and others through the saliva, blood and others non-invasively.
A scheiner-principle vernier optometer
NASA Astrophysics Data System (ADS)
Cushman, William B.
1989-06-01
A method and optometer apparatus is disclosed for measuring the dark focus of accommodation. In a preferred embodiment, the optometer apparatus includes: a pinhole aperture plate having first and second horizontally positioned apertures disposed on opposite sides of a first optical axis; first and second orthogonally-oriented polarizing filters respectively covering the first and second horizontally positioned apertures; a positive lens having an optical axis on the first optical axis and being positioned at a distance of approximately one focal length from the pinhole aperture plate; a lens system having an optical axis on the first optical axis; a slit aperture plate having a vertical slit and being disposed on the first optical axis and between the positive lens and the lens system; third and fourth vertically positioned polarizing filters selectively disposed adjacent to the slit aperture plate to divide the slit vertically, a monochromatic light source for propagating light along the first optical axis through the lens system; and movable means attached to the slit aperture plate, the lens system and the monochromatic light source for moving the slit aperture plate.
Focusing and directional beaming effects of airborne sound through a planar lens with zigzag slits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tang, Kun; Qiu, Chunyin, E-mail: cyqiu@whu.edu.cn; Lu, Jiuyang
2015-01-14
Based on the Huygens-Fresnel principle, we design a planar lens to efficiently realize the interconversion between the point-like sound source and Gaussian beam in ambient air. The lens is constructed by a planar plate perforated elaborately with a nonuniform array of zigzag slits, where the slit exits act as subwavelength-sized secondary sources carrying desired sound responses. The experiments operated at audible regime agree well with the theoretical predictions. This compact device could be useful in daily life applications, such as for medical and detection purposes.
Ion source for high-precision mass spectrometry
Todd, P.J.; McKown, H.S.; Smith, D.H.
1982-04-26
The invention is directed to a method for increasing the precision of positive-ion relative abundance measurements conducted in a sector mass spectrometer having an ion source for directing a beam of positive ions onto a collimating slit. The method comprises incorporating in the source an electrostatic lens assembly for providing a positive-ion beam of circular cross section for collimation by the slit. 2 figures, 3 tables.
Design of a Prototype Positive Ion Source with Slit Aperture Type Extraction System
NASA Astrophysics Data System (ADS)
Sharma, Sanjeev K.; Vattilli, Prahlad; Choksi, Bhargav; Punyapu, Bharathi; Sidibomma, Rambabu; Bonagiri, Sridhar; Aggrawal, Deepak; Baruah, Ujjwal K.
2017-04-01
The neutral beam injector group at IPR aims at developing an experimental positive ion source capable of delivering H+ ion beam having energy of 30 - 40 keV and carrying an ion beam current of 5 A. The slit aperture based extraction system is chosen for extracting and accelerating the ions so as to achieve low divergence of the ion beam (< 0.5°). For producing H+ ions a magnetic multi-pole bucket type plasma chamber is selected. We calculated the magnetic field due to cusp magnets and trajectories (orbits) of the primary electrons to investigate the two magnetic configurations i.e. line cusp and checker board. Numerical simulation is also carried out by using OPERA-3D to study the characteristic performance of the slit aperture type extraction-acceleration system. We report here the results of the studies carried out on various aspects of the design of the slit aperture type positive ion source.
Apparatus and method for a light direction sensor
NASA Technical Reports Server (NTRS)
Leviton, Douglas B. (Inventor)
2011-01-01
The present invention provides a light direction sensor for determining the direction of a light source. The system includes an image sensor; a spacer attached to the image sensor, and a pattern mask attached to said spacer. The pattern mask has a slit pattern that as light passes through the slit pattern it casts a diffraction pattern onto the image sensor. The method operates by receiving a beam of light onto a patterned mask, wherein the patterned mask as a plurality of a slit segments. Then, diffusing the beam of light onto an image sensor and determining the direction of the light source.
Balashov, Victor; Cherkasova, Maria; Kruglov, Kirill; Kudriavtsev, Arseny; Masherov, Pavel; Mogulkin, Andrey; Obukhov, Vladimir; Riaby, Valentin; Svotina, Victoria
2017-08-01
A theoretical-experimental research has been carried out to determine the characteristics of a radio frequency (RF) ion source for the generation of a weakly expanding wedge-shaped xenon ion beam. Such ion beam geometry is of interest as a prototype of an on-board ion injector for contactless "ion shepherding" by service spacecraft to remove large space debris objects from geostationary orbits. The wedge shape of the ion beam increases its range. The device described herein comprises an inductive gas discharge chamber and a slit-type three-electrode ion extraction grid (IEG) unit. Calculations of accelerating cell geometries and ion trajectories determined the dependence of beam expansion half-angle on normalized perveance based on the measurements of the spatial distributions of the xenon plasma parameters at the IEG entrance for a xenon flow rate q ≈ 0.2 mg/s and an incident RF power P in ≤ 250 W at a driving frequency f = 2 MHz. Experimental studies showed that the ion beam, circular at the IEG exit, accepted the elliptical form at the distance of 580 mm with half-angle of beam expansion across IEG slits about 2°-3° and close to 0° along them. Thus, the obtained result proved the possibility of creating a new-generation on-board ion injector that could be used in spacecrafts for removal of debris.
HIGH RESOLUTION EMITTANCE MEASUREMENTS AT SNS FRONT END
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aleksandrov, Alexander V; Zhukov, Alexander P
2013-01-01
The Spallation Neutron Source (SNS) linac accelerates an H- beam from 2.5MeV up to 1GeV. Recently the emittance scanner in the MEBT (2.5 MeV) was upgraded. In addition to the slit - harp measurement, we now can use a slit installed on the same actuator as the harp. In combination with a faraday cup located downstream in DTL part of the linac, it represents a classical slit-slit emittance measurement device. While a slit slit scan takes much longer, it is immune to harp related problems such as wire cross talk, and thus looks promising for accurate halo measurements. Time resolutionmore » of the new device seems to be sufficient to estimate the amount of beam in the chopper gap (the scanner is downstream of the chopper), and probably to measure its emittance. This paper describes the initial measurements with the new device and some model validation data.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cen Jianyong; Yuan Ping; Qu Haiyan
2011-11-15
According to the spectra of cloud-to-ground (CG) lightning discharge plasma captured by a slit-less spectrograph and the information of synchronous radiated electric field, the temperatures, the total intensity of spectra, the peak value of current and its action integral of discharge plasma channel have been calculated. Furthermore, the correlativity of these parameters has been analyzed for the first time. The results indicate that the total intensity of spectra has a positive correlation to the discharge current in different strokes of one CG lightning, and the temperature of discharge plasma is direct proportion to the action integral in the first returnmore » strokes of different lightning.« less
Single slit interference made easy with a strand of hair and a laser
NASA Astrophysics Data System (ADS)
Messer, Rebecca
2018-01-01
Students can easily measure the width of a strand of their own hair with a monochromatic light source such as a laser. This inexpensive activity engages students in an application of single slit diffraction using Babinet's principle.
Slit Function Measurement of An Imaging Spectrograph Using Fourier Transform Techniques
NASA Technical Reports Server (NTRS)
Park, Hongwoo; Swimyard, Bruce; Jakobsen, Peter; Moseley, Harvey; Greenhouse, Matthew
2004-01-01
Knowledge of a spectrograph slit function is necessary to interpret the unresolved lines in an observed spectrum. A theoretical slit function can be calculated from the sizes of the entrance slit, the detector aperture when it functions as an exit slit, the dispersion characteristic of the disperser, and the point spread function of the spectrograph. A measured slit function is preferred to the theoretical one for the correct interpretation of the spectral data. In a scanning spectrometer with a single exit slit, the slit function is easily measured. In a fixed grating/or disperser spectrograph, illuminating the entrance slit with a near monochromatic light from a pre-monochrmator or a tunable laser and varying the wavelength of the incident light can measure the slit function. Even though the latter technique had been used successfully for the slit function measurements, it had been very laborious and it would be prohibitive to an imaging spectrograph or a multi-object spectrograph that has a large field of view. We explore an alternative technique that is manageable for the measurements. In the proposed technique, the imaging spectrograph is used as a detector of a Fourier transform spectrometer. This method can be applied not only to an IR spectrograph but also has a potential to a visible/UV spectrograph including a wedge filter spectrograph. This technique will require a blackbody source of known temperature and a bolometer to characterize the interferometer part of the Fourier Transform spectrometer. This pa?er will describe the alternative slit function measurement technique using a Fourier transform spectrometer.
Oppenheimer, F.
1958-08-19
The construction of an ion source is descrtbed wherein a uniform and elongated arc is established for employment in a calutron. The novel features of the . source include the positioning of a cathode at one end of an elongated extt slit of an arc chamber. and anode electrodes defintng the longitudinal margins of the exit opening. When the exit slit is orientated in a parallel relation to a magnetic field, the arc extends in the direction of the magnetic field along and between the anode electrodes, which are held at a positsve potential with respect to the cathode.
Presumed minor salivary gland secretion in a patient with a history of oral mucous membrane graft.
Kitagawa, Kiyotaka; Hayasaka, Seiji; Matsunou, Hisao; Nagaki, Yasunori
2003-08-01
To describe presumed minor salivary gland secretion in a patient with a history of oral mucous membrane graft in conjunctival plastic surgery. Interventional case report. A 74-year-old woman who had had an oral mucous membrane graft in the left eye complained of mucous discharge. Slit-lamp examination revealed a yellowish-red mass lesion in the superior bulbar conjunctiva. The lesion was excised. Histopathologic examination of the excised tissue revealed lobules and a duct of minor salivary glands. After removal of the mass, mucous discharge decreased. Minor salivary glands within a mucous membrane graft may cause mucous discharge in the eye.
Slit-Slat Collimator Equipped Gamma Camera for Whole-Mouse SPECT-CT Imaging
NASA Astrophysics Data System (ADS)
Cao, Liji; Peter, Jörg
2012-06-01
A slit-slat collimator is developed for a gamma camera intended for small-animal imaging (mice). The tungsten housing of a roof-shaped collimator forms a slit opening, and the slats are made of lead foils separated by sparse polyurethane material. Alignment of the collimator with the camera's pixelated crystal is performed by adjusting a micrometer screw while monitoring a Co-57 point source for maximum signal intensity. For SPECT, the collimator forms a cylindrical field-of-view enabling whole mouse imaging with transaxial magnification and constant on-axis sensitivity over the entire axial direction. As the gamma camera is part of a multimodal imaging system incorporating also x-ray CT, five parameters corresponding to the geometric displacements of the collimator as well as to the mechanical co-alignment between the gamma camera and the CT subsystem are estimated by means of bimodal calibration sources. To illustrate the performance of the slit-slat collimator and to compare its performance to a single pinhole collimator, a Derenzo phantom study is performed. Transaxial resolution along the entire long axis is comparable to a pinhole collimator of same pinhole diameter. Axial resolution of the slit-slat collimator is comparable to that of a parallel beam collimator. Additionally, data from an in-vivo mouse study are presented.
Chen, Jianjun; Sun, Chengwei; Li, Hongyun; Gong, Qihuang
2014-11-21
Surface-plasmon-polariton (SPP) launchers, which can couple the free space light to the SPPs on the metal surface, are among the key elements for the plasmonic devices and nano-photonic systems. Downscaling the SPP launchers below the diffraction limit and directly delivering the SPPs to the desired subwavelength plasmonic waveguides are of importance for high-integration plasmonic circuits. By designing a submicron double-slit structure with different slit widths, an ultra-broadband (>330 nm) unidirectional SPP launcher is realized theoretically and experimentally based on the different phase delays of SPPs propagating along the metal surface and the near-field interfering effect. More importantly, the broadband and unidirectional properties of the SPP launcher are still maintained when the slit length is reduced to a subwavelength scale. This can make the launcher occupy only a very small area of <λ(2)/10 on the metal surface. Such a robust unidirectional SPP launcher beyond the diffraction limit can be directly coupled to a subwavelength plasmonic waveguide efficiently, leading to an ultra-tight SPP source, especially as a subwavelength localized guided SPP source.
NASA Astrophysics Data System (ADS)
Lee, Hye-In; Pak, Soojong; Lee, Jae-Joon; Mace, Gregory N.; Jaffe, Daniel Thomas
2017-06-01
We developed an observation control software for the IGRINS (Immersion Grating Infrared Spectrograph) silt-viewing camera module, which points the astronomical target onto the spectroscopy slit and sends tracking feedbacks to the telescope control system (TCS). The point spread function (PSF) image is not following symmetric Gaussian profile. In addition, bright targets are easily saturated and shown as a donut shape. It is not trivial to define and find the center of the asymmetric PSF especially when most of the stellar PSF falls inside the slit. We made a center balancing algorithm (CBA) which derives the expected center position along the slit-width axis by referencing the stray flux ratios of both upper and lower sides of the slit. We compared accuracies of the CBA and those of a two-dimensional Gaussian fitting (2DGA) through simulations in order to evaluate the center finding algorithms. These methods were then verified with observational data. In this poster, we present the results of our tests and suggest a new algorithm for centering targets in the slit image of a spectrograph.
APPARATUS FOR PRODUCING IONS OF VAPORIZABLE MATERIALS
Wright, B.T.
1958-01-28
a uniform and copious supply of ions. The source comprises a hollow arc- block and means for establishing a magnetic field through the arc-block. Vaporization of the material to be ionized is produced by an electric heated filament. The arc producing structure within the arc-block consists of a cathode disposed between a pair of collimating electrodes along with an anode adjacent each collimating electrode on the side opposite the cathode. A positive potential applied to the anodes and collimating electrodes, with respect to the cathode, and the magnetic field act to accelerate the electrons from the cathode through a slit in each collimating clectrode towards the respective anode. In this manner a pair of collinear arc discharges are produced in the gas region which can be tapped for an abundant supply of ions of the material being analyzed.
Robust reflective pupil slicing technology
NASA Astrophysics Data System (ADS)
Meade, Jeffrey T.; Behr, Bradford B.; Cenko, Andrew T.; Hajian, Arsen R.
2014-07-01
Tornado Spectral Systems (TSS) has developed the High Throughput Virtual Slit (HTVSTM), robust all-reflective pupil slicing technology capable of replacing the slit in research-, commercial- and MIL-SPEC-grade spectrometer systems. In the simplest configuration, the HTVS allows optical designers to remove the lossy slit from pointsource spectrometers and widen the input slit of long-slit spectrometers, greatly increasing throughput without loss of spectral resolution or cross-dispersion information. The HTVS works by transferring etendue between image plane axes but operating in the pupil domain rather than at a focal plane. While useful for other technologies, this is especially relevant for spectroscopic applications by performing the same spectral narrowing as a slit without throwing away light on the slit aperture. HTVS can be implemented in all-reflective designs and only requires a small number of reflections for significant spectral resolution enhancement-HTVS systems can be efficiently implemented in most wavelength regions. The etendueshifting operation also provides smooth scaling with input spot/image size without requiring reconfiguration for different targets (such as different seeing disk diameters or different fiber core sizes). Like most slicing technologies, HTVS provides throughput increases of several times without resolution loss over equivalent slitbased designs. HTVS technology enables robust slit replacement in point-source spectrometer systems. By virtue of pupilspace operation this technology has several advantages over comparable image-space slicer technology, including the ability to adapt gracefully and linearly to changing source size and better vertical packing of the flux distribution. Additionally, this technology can be implemented with large slicing factors in both fast and slow beams and can easily scale from large, room-sized spectrometers through to small, telescope-mounted devices. Finally, this same technology is directly applicable to multi-fiber spectrometers to achieve similar enhancement. HTVS also provides the ability to anamorphically "stretch" the slit image in long-slit spectrometers, allowing the instrument designer to optimize the plate scale in the dispersion axis and cross-dispersion axes independently without sacrificing spatial information. This allows users to widen the input slit, with the associated gain of throughput and loss of spatial selectivity, while maintaining the spectral resolution of the spectrometer system. This "stretching" places increased requirements on detector focal plane height, as with image slicing techniques, but provides additional degrees of freedom to instrument designers to build the best possible spectrometer systems. We discuss the details of this technology for an astronomical context, covering the applicability from small telescope mounted spectrometers through long-slit imagers and radial-velocity engines. This powerful tool provides additional degrees of freedom when designing a spectrometer, enabling instrument designers to further optimize systems for the required scientific goals.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spaedtke, P.; Lang, R.; Maeder, J.
2012-02-15
Using improved beam diagnostic tools, the structure of an ion beam extracted from an electron cyclotron resonance ion source (ECRIS) becomes visible. Especially viewing targets to display the beam profile and pepper pot devices for emittance measurements turned out to be very useful. On the contrary, diagnostic tools integrating over one space coordinate like wire harps for profile measurements or slit-slit devices, respectively slit-grid devices to measure the emittance might be applicable for beam transport investigations in a quadrupole channel, but are not very meaningful for investigations regarding the given ECRIS symmetry. Here we try to reproduce the experimentally foundmore » structure on the ion beam by simulation. For the simulation, a certain model has to be used to reproduce the experimental results. The model is also described in this paper.« less
Schwend, Tyler; Lwigale, Peter Y.; Conrad, Gary W.
2012-01-01
The cornea, the most densely innervated tissue on the surface of the body, becomes innervated in a series of highly coordinated developmental events. During cornea development, chick trigeminal nerve growth cones reach the cornea margin at embryonic day (E)5, where they are initially repelled for days from E5-8, instead encircling the corneal periphery in a nerve ring prior to entering on E9. The molecular events coordinating growth cone guidance during cornea development are poorly understood. Here we evaluated a potential role for the Robo-Slit nerve guidance family. We found that Slit 1, 2 and 3 expression in the cornea and lens persisted during all stages of cornea innervation examined. Robo1 expression was developmentally regulated in trigeminal cell bodies, expressed robustly during nerve ring formation (E5-8), then later declining concurrent with projection of growth cones into the cornea. In this study we provide in vivo and in vitro evidence that Robo-Slit signaling guides trigeminal nerves during cornea innervation. Transient, localized inhibition of Robo-Slit signaling, by means of beads loaded with inhibitory Robo-Fc protein implanted into the developing eyefield in vivo, led to disorganized nerve ring formation and premature cornea innervation. Additionally, when trigeminal explants (source of neurons) were oriented adjacent to lens vesicles or corneas (source of repellant molecules) in organotypic tissue culture both lens and cornea tissues strongly repelled E7 trigeminal neurites, except in the presence of inhibitory Robo-Fc protein. In contrast, E10 trigeminal neurites were not as strongly repelled by cornea, and presence of Robo-Slit inhibitory protein had no effect. In full, these findings suggest that nerve repulsion from the lens and cornea during nerve ring formation is mediated by Robo-Slit signaling. Later, a shift in nerve guidance behavior occurs, in part due to molecular changes in trigeminal neurons, including Robo1 downregulation, thus allowing nerves to find the Slit-expressing cornea permissive for growth cones. PMID:22236962
Geisen, Marc J; Di Meglio, Thomas; Pasqualetti, Massimo; Ducret, Sebastien; Brunet, Jean-François; Chedotal, Alain; Rijli, Filippo M
2008-06-10
The pontine neurons (PN) represent a major source of mossy fiber projections to the cerebellum. During mouse hindbrain development, PN migrate tangentially and sequentially along both the anteroposterior (AP) and dorsoventral (DV) axes. Unlike DV migration, which is controlled by the Netrin-1/Dcc attractive pathway, little is known about the molecular mechanisms guiding PN migration along the AP axis. Here, we show that Hoxa2 and Hoxb2 are required both intrinsically and extrinsically to maintain normal AP migration of subsets of PN, by preventing their premature ventral attraction towards the midline. Moreover, the migration defects observed in Hoxa2 and Hoxb2 mutant mice were phenocopied in compound Robo1;Robo2, Slit1;Slit2, and Robo2;Slit2 knockout animals, indicating that these guidance molecules act downstream of Hox genes to control PN migration. Indeed, using chromatin immunoprecipitation assays, we further demonstrated that Robo2 is a direct target of Hoxa2 in vivo and that maintenance of high Robo and Slit expression levels was impaired in Hoxa2 mutant mice. Lastly, the analysis of Phox2b-deficient mice indicated that the facial motor nucleus is a major Slit signaling source required to prevent premature ventral migration of PN. These findings provide novel insights into the molecular control of neuronal migration from transcription factor to regulation of guidance receptor and ligand expression. Specifically, they address the question of how exposure to multiple guidance cues along the AP and DV axes is regulated at the transcriptional level and in turn translated into stereotyped migratory responses during tangential migration of neurons in the developing mammalian brain.
Hox Paralog Group 2 Genes Control the Migration of Mouse Pontine Neurons through Slit-Robo Signaling
Pasqualetti, Massimo; Ducret, Sebastien; Brunet, Jean-François; Chedotal, Alain; Rijli, Filippo M
2008-01-01
The pontine neurons (PN) represent a major source of mossy fiber projections to the cerebellum. During mouse hindbrain development, PN migrate tangentially and sequentially along both the anteroposterior (AP) and dorsoventral (DV) axes. Unlike DV migration, which is controlled by the Netrin-1/Dcc attractive pathway, little is known about the molecular mechanisms guiding PN migration along the AP axis. Here, we show that Hoxa2 and Hoxb2 are required both intrinsically and extrinsically to maintain normal AP migration of subsets of PN, by preventing their premature ventral attraction towards the midline. Moreover, the migration defects observed in Hoxa2 and Hoxb2 mutant mice were phenocopied in compound Robo1;Robo2, Slit1;Slit2, and Robo2;Slit2 knockout animals, indicating that these guidance molecules act downstream of Hox genes to control PN migration. Indeed, using chromatin immunoprecipitation assays, we further demonstrated that Robo2 is a direct target of Hoxa2 in vivo and that maintenance of high Robo and Slit expression levels was impaired in Hoxa2 mutant mice. Lastly, the analysis of Phox2b-deficient mice indicated that the facial motor nucleus is a major Slit signaling source required to prevent premature ventral migration of PN. These findings provide novel insights into the molecular control of neuronal migration from transcription factor to regulation of guidance receptor and ligand expression. Specifically, they address the question of how exposure to multiple guidance cues along the AP and DV axes is regulated at the transcriptional level and in turn translated into stereotyped migratory responses during tangential migration of neurons in the developing mammalian brain. PMID:18547144
Imamura, Hitoshi; Tabuchi, Hitoshi; Nakakura, Shunsuke; Nagasato, Daisuke; Baba, Hiroaki; Kiuchi, Yoshiaki
2018-04-01
To investigate the usability and the reproducibility of the tear meniscus values via swept-source optical coherence tomography (SS-OCT) and the conventional slit lamp microscope method with a graticule. The right eye was examined in 90 healthy adult subjects who were grouped according to age (group 1: 20-39 years; group 2: 40-59 years; group 3: ≥60 years). The tear meniscus height (TMH) and tear meniscus area were measured using SS-OCT and TMH by the slit lamp microscope method. The reproducibility of each method was calculated using intraclass correlation coefficients (ICCs) in additionally enrolled 30 healthy young subjects. We also evaluated TMH at 3 mm from the corneal center in both temporal and nasal directions using SS-OCT. The mean of the TMH values measured by SS-OCT was significantly higher than those measured by the slit lamp method (328 vs. 212 μm, P < 0.001, respectively). High reproducibility was observed for each method (ICC > 0.75 for both). No statistically significant differences were found in TMH among the age groups using both SS-OCT and slit lamp methods (P = 0.985, 0.380, respectively). TMH values at both sides of the corneal center were significantly smaller than those at the corneal center (P < 0.0001). TMH values obtained by the slit lamp method were lower than those obtained by SS-OCT. However, both methods yielded highly reproducible TMH measurements, suggesting that they are clinically useful. Tear meniscus values did not vary by age but by measurement points in our cohort.
NASA Technical Reports Server (NTRS)
1989-01-01
Electro-Expulsive Separation System, a low power electro-thermal deicer, was invented by Leonard A. Haslim from the Ames Research Center, who was named 1988 NASA Inventor of the Year for his work. Sold under license by Dataproducts New England, Inc., it consists of an elastic, rubber-like deicer boot on the wing's leading edge with copper ribbons embedded in it. Conductors are separated by slits in between and parallel to the ribbons. When the system is switched on, a bank of capacitors in the power supply discharges into the conductors which induces the conductor pairs to repel each other. This results in a powerful force causing the slit voids to expand explosively, removing ice on the wing. EESS is more flexible, more effective, and easier to maintain than previous systems. Potential ship, bridge and industrial applications are under study.
The Spartan-281 Far Ultraviolet Imaging Spectrograph
NASA Technical Reports Server (NTRS)
Carruthers, George R.; Heckathorn, Harry M.; Dufour, Reginald J.; Opal, Chet B.; Raymond, John C.
1988-01-01
The U.S. Naval Research Laboratory's Far Ultraviolet Imaging Spectrograph (FUVIS), currently under development for flight as a Spartan shuttle payload, is designed to perform spectroscopy of diffuse sources in the FUV with very high sensitivity and moderate spatial and spectral resolution. Diffuse nebulae, the general galactic background radiation, and artificially induced radiation associated with the Space Shuttle vehicle are sources of particular interest. The FUVIS instrument will cover the wavelength range of 970-2000 A with selectable resolutions of 5 and 30 A. It is a slit imaging spectrograph having 3 arcmin spatial resolution along its 2.7 deg long slit.
NASA Astrophysics Data System (ADS)
Rebelo Kornmeier, Joana; Ostermann, Andreas; Hofmann, Michael; Gibmeier, Jens
2014-02-01
Neutron strain diffractometers usually use slits to define a gauge volume within engineering samples. In this study a multi-channel parabolic neutron guide was developed to be used instead of the primary slit to minimise the loss of intensity and vertical definition of the gauge volume when using slits placed far away from the measurement position in bulky components. The major advantage of a focusing guide is that the maximum flux is not at the exit of the guide as for a slit system but at the focal point relatively far away from the exit of the guide. Monte Carlo simulations were used to optimise the multi-channel parabolic guide with respect to the instrument characteristics of the diffractometer STRESS-SPEC at the FRM II neutron source. Also the simulations are in excellent agreement with experimental measurements using the optimised multi-channel parabolic guide at the neutron diffractometer. In addition the performance of the guide was compared to the standard slit setup at STRESS-SPEC using a single bead weld sample used in earlier round robin tests for residual strain measurements.
Parameter estimation for slit-type scanning sensors
NASA Technical Reports Server (NTRS)
Fowler, J. W.; Rolfe, E. G.
1981-01-01
The Infrared Astronomical Satellite, scheduled for launch into a 900 km near-polar orbit in August 1982, will perform an infrared point source survey by scanning the sky with slit-type sensors. The description of position information is shown to require the use of a non-Gaussian random variable. Methods are described for deciding whether separate detections stem from a single common source, and a formulism is developed for the scan-to-scan problems of identifying multiple sightings of inertially fixed point sources for combining their individual measurements into a refined estimate. Several cases are given where the general theory yields results which are quite different from the corresponding Gaussian applications, showing that argument by Gaussian analogy would lead to error.
Fundamental Parameters Line Profile Fitting in Laboratory Diffractometers
Cheary, R. W.; Coelho, A. A.; Cline, J. P.
2004-01-01
The fundamental parameters approach to line profile fitting uses physically based models to generate the line profile shapes. Fundamental parameters profile fitting (FPPF) has been used to synthesize and fit data from both parallel beam and divergent beam diffractometers. The refined parameters are determined by the diffractometer configuration. In a divergent beam diffractometer these include the angular aperture of the divergence slit, the width and axial length of the receiving slit, the angular apertures of the axial Soller slits, the length and projected width of the x-ray source, the absorption coefficient and axial length of the sample. In a parallel beam system the principal parameters are the angular aperture of the equatorial analyser/Soller slits and the angular apertures of the axial Soller slits. The presence of a monochromator in the beam path is normally accommodated by modifying the wavelength spectrum and/or by changing one or more of the axial divergence parameters. Flat analyzer crystals have been incorporated into FPPF as a Lorentzian shaped angular acceptance function. One of the intrinsic benefits of the fundamental parameters approach is its adaptability any laboratory diffractometer. Good fits can normally be obtained over the whole 20 range without refinement using the known properties of the diffractometer, such as the slit sizes and diffractometer radius, and emission profile. PMID:27366594
NASA Astrophysics Data System (ADS)
Froger, E.; Marque, J. P.
The electromagnetic response of an orbiting satellite to an electrostatic discharge is compared to that of the same object subjected (in a susceptibility test) to an injection current. In the absence of actual data, the comparison was performed on the basis of two numerical simulations: one using the GEODE particle code for the orbiting case, and the other using the ALICE code for a representative injection configuration. It is found that the evolution of the electromagnetic fields is controlled in particular by the particle emission rhythm, giving rise to an ejection flux 'slit' whose rise time is about several tens of nanoseconds.
Laser synchronized high-speed shutter for spectroscopic application
Miles, Paul C.; Porter, Eldon L.; Prast, Thomas L.; Sunnarborg, Duane A.
2002-01-01
A fast mechanical shutter, based on rotating chopper wheels, has been designed and implemented to shutter the entrance slit of a spectrograph. This device enables an exposure time of 9 .mu.s to be achieved for a 0.8 mm wide spectrograph entrance slit, achieves 100% transmission in the open state, and an essentially infinite extinction ratio. The device further incorporates chopper wheel position sensing electronics to permit the synchronous triggering of a laser source.
Slit-check dams for the control of debris flow
NASA Astrophysics Data System (ADS)
Armanini, Aronne; Larcher, Michele
2017-04-01
Debris flows are paroxysmal events that mobilize, alongside water, huge quantities of sediment in a very short time, then with both solid and liquid huge discharges, possibly exceeding the capacity of the current torrent restoration works. In this respect, the climate change forcing cannot be ignored. In the majority of urbanized areas, that are generally the most vulnerable, there is often not enough space to create channelling works able to let the volumes pass through without overflowing. The simplest, less expensive and most sustainable solution consists in reducing the peak solid discharge by creating storage areas upstream of the settlements, typically upstream of the alluvial fans, allowing for reduced works of canalization, that are compatible with the constraints imposed by the urbanization. The general idea consists in storing a part of the flowing solids during the peak of the hydrograph and releasing it in a successive phase or during minor floods. For this purpose, and in order to optimize the solid peak discharge reduction, it is necessary that properly designed open-check dams, capable of inducing a significative sedimentation of the solid discharge only when this exceeds a design-threshold value, control the deposition basins. A correct design of the check dam is crucial in order to induce the sedimentation in the right amount and at the right moment: a too early sedimentation might fill the volume before the peak, like in the case of close-check dams, while a too weak sedimentation might not use the whole available volume. In both cases, the channelling works might not be sufficient to let all the flow pass through, compromising the safety of the settlement. To avoid this inconvenience, we propose the use of slit-check dams, whose efficiency has already been proved for bed load. Check dams are often designed only on the base of the designer's experience. Besides, even today it is often believed that the filtering effect of open check dams is exerted through a mechanical sieve, while it was proved that the retention of the solid material is rather due to a hydrodynamic effect induced by the narrowing of the section. Also in the case of debris flow, through proper balances of liquid and solid mass and energy it is possible to obtain a rational criterion for designing the width of the slit in order to obtain a sediment deposition of desired elevation for a given design discharge. In this way the use of the retention basin can be optimized in order to maximize the reduction of the debris flow peak discharge. Flume experiments were carried out in steady conditions at the University of Trento and confirmed with good agreement the prediction of the theory. As in the case of ordinary sediment transport, the clogging induced by the vegetal material represents the major problem for the operational reliability of this systems and needs therefore to be further investigated.
Double-slit experiment with single wave-driven particles and its relation to quantum mechanics.
Andersen, Anders; Madsen, Jacob; Reichelt, Christian; Rosenlund Ahl, Sonja; Lautrup, Benny; Ellegaard, Clive; Levinsen, Mogens T; Bohr, Tomas
2015-07-01
In a thought-provoking paper, Couder and Fort [Phys. Rev. Lett. 97, 154101 (2006)] describe a version of the famous double-slit experiment performed with droplets bouncing on a vertically vibrated fluid surface. In the experiment, an interference pattern in the single-particle statistics is found even though it is possible to determine unambiguously which slit the walking droplet passes. Here we argue, however, that the single-particle statistics in such an experiment will be fundamentally different from the single-particle statistics of quantum mechanics. Quantum mechanical interference takes place between different classical paths with precise amplitude and phase relations. In the double-slit experiment with walking droplets, these relations are lost since one of the paths is singled out by the droplet. To support our conclusions, we have carried out our own double-slit experiment, and our results, in particular the long and variable slit passage times of the droplets, cast strong doubt on the feasibility of the interference claimed by Couder and Fort. To understand theoretically the limitations of wave-driven particle systems as analogs to quantum mechanics, we introduce a Schrödinger equation with a source term originating from a localized particle that generates a wave while being simultaneously guided by it. We show that the ensuing particle-wave dynamics can capture some characteristics of quantum mechanics such as orbital quantization. However, the particle-wave dynamics can not reproduce quantum mechanics in general, and we show that the single-particle statistics for our model in a double-slit experiment with an additional splitter plate differs qualitatively from that of quantum mechanics.
Double-slit interferometry with a Bose-Einstein condensate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Collins, L.A.; Berman, G.P.; Bishop, A.R.
2005-03-01
A Bose-Einstein 'double-slit' interferometer has been recently realized experimentally by Y. Shin et al., Phys. Rev. Lett. 92 050405 (2004). We analyze the interferometric steps by solving numerically the time-dependent Gross-Pitaevskii equation in three-dimensional space. We focus on the adiabaticity time scales of the problem and on the creation of spurious collective excitations as a possible source of the strong degradation of the interference pattern observed experimentally. The role of quantum fluctuations is discussed.
A high flux source of swift oxygen atoms
NASA Technical Reports Server (NTRS)
Fink, M.; Kohl, D. A.; Keto, J. W.; Antoniewicz, P.
1987-01-01
A source of swift oxygen atoms is described which has several unique features. A high current ion beam is produced by a microwave discharge, accelerated to 10 keV and the mass selected by a modified Du Pont 21-110 mass spectrometer. The O(+) beam exciting the mass spectrometer is focused into a rectangular shape with an energy spread of less than 1 eV. The next section of the machine decelerates the ion beam into a counterpropagating electron beam in order to minimize space charge effects. After deceleration, the ion beam intersects at 90 deg, a neutral oxygen atom beam, which via resonant charge exchange produces a mixture of O(+) and O. Any remaining O(+) are swept out of the beam by an electric field and differentially pumped away while the desired O beam, collimated by slits, impinges on the target. In situ monitoring of the target surface is done by X-ray photoelectron or Auger spectroscopy. Faraday cups provide flux measurements in the ion sections while the neutral flux is determined by a special torsion balance or by a quadrupole mass spectrometer specially adapted for swift atoms. While the vacuum from the source through the mass spectrometer is maintained by diffusion pumps, the rest of the machine is UHV.
Detection of Real Flaw using Uniform Eddy Current Multi-probe
NASA Astrophysics Data System (ADS)
Fukuoka, Katsuhiro; Hashimoto, Mitsuo
The establishment of the nondestructive inspection technology with plant structures has been stimulated by the recent occurrence of cracks in the nuclear power plant structures. In this research, a uniform eddy current multi-probe to apply to the complex structure and inspect the cracks at high-speed data acquisition was developed. Pick-up coils of the developed probe were arranged on a flexible printed circuit board. This probe was able to obtain clear signal for an EDM (electro-discharge machining) slit with 0.5 mm depth and distinguish EDM slits arranged at 2 mm intervals. It was confirmed that the SCC (stress corrosion cracking) of real flaw was able to be detected with developed uniform eddy current multi-probe by using the ferrite core for the exciting coil and considering the impedance matching of the exciting coil and the flaw detection device.
H- beam transport experiments in a solenoid low energy beam transport.
Gabor, C; Back, J J; Faircloth, D C; Izaola, Z; Lawrie, S R; Letchford, A P
2012-02-01
The Front End Test Stand (FETS) is located at Rutherford Appleton Laboratory and aims for a high current, fast chopped 3 MeV H(-) ion beam suitable for future high power proton accelerators like ISIS upgrade. The main components of the front end are the Penning ion source, a low energy beam transport line, an radio-frequency quadrupole (RFQ) and a medium energy beam transport (MEBT) providing also a chopper section and rebuncher. FETS is in the stage of commissioning its low energy beam transport (LEBT) line consisting of three solenoids. The LEBT has to transport an H(-) high current beam (up to 60 mA) at 65 keV. This is the injection energy of the beam into the RFQ. The main diagnostics are slit-slit emittance scanners for each transversal plane. For optimizing the matching to the RFQ, experiments have been performed with a variety of solenoid settings to better understand the actual beam transport. Occasionally, source parameters such as extractor slit width and beam energy were varied as well. The paper also discusses simulations based on these measurements.
New redshift determinations for three 3C radio sources.
NASA Astrophysics Data System (ADS)
Reynaldi, V.
2017-01-01
I report the new redshift determinations of three radio sources 3C 196.1, 3C 268.2 and 3C 303.1 by using GMOS/Gemini North long-slit optical spectroscopy. The details of the observations are summarized in the following table (the B600 grating was used for the three observations): Object | RA(J2000) | DEC(J2000) | Date of obs. | width-slit(arcsec) | PA(deg) | Exp.Time(sec) 3C 196.1 | 8:15:27.8 | -03:08:27 | Mar 2012 | 0.5 | 50 | 2560 3C 268.2| |12:00:59.1 | 31:33:28 | Feb 2011 | 0.5 | 165 | 2576 3C 303.1 | 14:43:14.5 | 77:07:28 | Feb 2012 | 1 | 145 | 2560 The three of the sources have extended regions of ionized gas that do not obey a spherical distribution.
Optical double-slit particle measuring system
Tichenor, D.A.; Wang, J.C.F.; Hencken, K.R.
1982-03-25
A method for in situ measurement of particle size is described. The size information is obtained by scanning an image of the particle across a double-slit mask and observing the transmitted light. This method is useful when the particle size of primary interest is 3..mu..m and larger. The technique is well suited to applications in which the particles are non-spherical and have unknown refractive index. It is particularly well suited to high temperature environments in which the particle incandescence provides the light source.
Optical double-slit particle measuring system
Hencken, Kenneth R.; Tichenor, Daniel A.; Wang, James C. F.
1984-01-01
A method for in situ measurement of particle size is described. The size information is obtained by scanning an image of the particle across a double-slit mask and observing the transmitted light. This method is useful when the particle size of primary interest is 3 .mu.m and larger. The technique is well suited to applications in which the particles are non-spherical and have unknown refractive index. It is particularly well suited to high temperature environments in which the particle incandescence provides the light source.
Rotating Modulation Imager for the Orphan Source Search Problem
2008-01-01
black mask. If the photon hits an open element it is transmitted and the function M(x) = 1. If the photon hits a closed mask element it is not...photon enters the top mask pair in the third slit, but passes through the second slit on the bottom mask. With a single black mask this is physically...modulation efficiency changes as a function of mask thickness for both tungsten and lead masks. The black line shows how the field of view changes with
Sub-Doppler infrared spectroscopy of propargyl radical (H{sub 2}CCCH) in a slit supersonic expansion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, Chih-Hsuan; Nesbitt, David J.
The acetylenic CH stretch mode (ν{sub 1}) of propargyl (H{sub 2}CCCH) radical has been studied at sub-Doppler resolution (∼60 MHz) via infrared laser absorption spectroscopy in a supersonic slit-jet discharge expansion, where low rotational temperatures (T{sub rot} = 13.5(4) K) and lack of spectral congestion permit improved determination of band origin and rotational constants for the excited state. For the lowest J states primarily populated in the slit jet cooled expansion, fine structure due to the unpaired electron spin is resolved completely, which permits accurate analysis of electron spin-rotation interactions in the vibrationally excited states (ε{sub aa} = − 518.1(1.8),more » ε{sub bb} = − 13.0(3), ε{sub cc} = − 1.8(3) MHz). In addition, hyperfine broadening in substantial excess of the sub-Doppler experimental linewidths is observed due to nuclear spin–electron spin contributions at the methylenic (—CH{sub 2}) and acetylenic (—CH) positions, which permits detailed modeling of the fine/hyperfine structure line contours. The results are consistent with a delocalized radical spin density extending over both methylenic and acetylenic C atoms, in excellent agreement with simple resonance structures as well as ab initio theoretical calculations.« less
Slit lamps and lenses: a potential source of nosocomial infections?
Sobolewska, Bianka; Buhl, Michael; Liese, Jan; Ziemssen, Focke
2018-01-30
The aim of the study was to evaluate the bacterial contamination level of contact surfaces on slit lamps and the grip areas of lenses. Within unannounced audits, two regions of the slit lamps (headrest and joystick), indirect ophthalmoscopy devices, and ultrasound probes were obtained with rayon-tipped swab. Non-contact lenses used for indirect fundoscopy were pressed on RODAC (Replicate Organism Detection and Counting) plates. One hundred and eighty-one surfaces were sampled. The total number of colony-forming units was assessed and bacterial species were identified. Spa-typing and antimicrobial susceptibility testing were performed from Staphylococcus aureus isolates. Among the total bacterial isolates from ophthalmological equipment (lenses: 51 of 78, slit lamps: 43 of 88, ophthalmoscopy helmets: 3 of 8, ultrasound probes: 2 of 7), coagulase-negative staphylococci (CNS) was most frequently found, followed by Micrococcus spp. (lenses vs. slit lamps: P < 0.001 and P = 0.01, respectively). The bacterial contamination of lenses (76%) was significantly higher than that of slit lamps (54%) (P < 0.003). A significantly higher contamination with CNS was observed on lenses from residents vs. from consultants (78% vs. 35%, P = 0.01). A total of seven different spa-types of S. aureus were isolated. No correlation was found between S. aureus contamination of different ophthalmological equipments (Spearman's rank correlation coefficient, ρ = 0.04, P = 0.75). Methicillin-resistant S. aureus was not detected. Bacterial species of the normal skin flora were isolated from the ophthalmological equipment. The bacterial contamination of the portable devices was significantly higher than that of slit lamps. Therefore, proper hygiene of the mobile instruments should be monitored in order to prevent transmission of bacteria in residents and consultants.
The Algorithm for MODIS Wavelength On-Orbit Calibration Using the SRCA
NASA Technical Reports Server (NTRS)
Montgomery, Harry; Che, Nianzeng; Parker, Kirsten; Bowser, Jeff
1998-01-01
The Spectro-Radiometric Calibration Assembly (SRCA) provides on-orbit spectral calibration of the MODerate resolution Imaging Spectroradiometer (MODIS) reflected solar bands and this paper describes how it is accomplished. The SRCA has two adjacent exit slits: 1) Main slit and 2) Calibration slit. The output from the main slit is measured by a reference silicon photo-diode (SIPD) and then passes through the MODIS. The output from the calibration slit passes through a piece of didymium transmission glass and then it is measured by a calibration SIPD. The centroids of the sharp spectral peaks of a didymium glass are utilized as wavelength standards. After normalization using the reference SIPD signal to eliminate the effects of the illuminating source spectra, the calibration SIPD establishes the relationship between the peaks of the didymium spectra and the grating angle; this is accomplished through the grating equation. In the grating equation the monochromator parameters, Beta (half angle between the incident and diffractive beams) and Theta(sub off) (offset angle of the grating motor) are determined by matching, in a least square sense, the known centroid wavelengths of the didymium peaks and the calculated centroid grating angles from the calibration SIPD signals for the peaks. A displacement between the calibration SIPD and the reference SIPD complicates the signal processing.
NASA Astrophysics Data System (ADS)
Turcu, I. C. E.; Ross, I. N.; Schulz, M. S.; Daido, H.; Tallents, G. J.; Krishnan, J.; Dwivedi, L.; Hening, A.
1993-06-01
The properties of a coherent x-ray point source in the water window spectral region generated using a small commercially available KrF laser system focused onto a Mylar (essentially carbon) target have been measured. By operating the source in a low-pressure (approximately 20 Torr) nitrogen environment, the degree of monochromaticity was improved due to the nitrogen acting as an x-ray filter and relatively enhancing the radiation at a wavelength of 3.37 nm (C vi 1s-2p). X-ray pinhole camera images show a minimum source size of 12 μm. A Young's double slit coherence measurement gave fringe visibilities of approximately 62% for a slit separation of 10.5 μm at a distance of 31.7 cm from the source. To demonstrate the viability of the laser plasma as a source for coherent imaging applications a Gabor (in-line) hologram of two carbon fibers, of different sizes, was produced. The exposure time and the repetition rate was 2 min and 10 Hz, respectively.
NASA Astrophysics Data System (ADS)
Fan, Tingting; Yuan, Ping; Wang, Xuejuan; Cen, Jianyong; Chang, Xuan; Zhao, Yanyan
2017-09-01
The spectra of two negative cloud-to-ground lightning discharge processes with multi-return strokes are obtained by a slit-less high-speed spectrograph, which the temporal resolution is 110 μs. Combined with the synchronous electrical observation data and theoretical calculation, the physical characteristics during return strokes process are analysed. A positive correlation between discharge current and intensity of ionic lines in the spectra is verified, and based on this feature, the current evolution characteristics during four return strokes are investigated. The results show that the time from peak current to the half-peak value estimated by multi point-fitting is about 101 μs-139 μs. The Joule heat in per unit length of four return strokes channel is in the order of 105J/m-106 J/m. The radius of arc discharge channel is positively related to the discharge current, and the more intense the current is, the greater the radius of channel is. Furthermore, the evolution for radius of arc core channel in the process of return stroke is consistent with the change trend of discharge current after the peak value. Compared with the decay of the current, the temperature decreases more slowly.
Simulating Irregular Source Geometries for Ionian Plumes
NASA Astrophysics Data System (ADS)
McDoniel, W. J.; Goldstein, D. B.; Varghese, P. L.; Trafton, L. M.; Buchta, D. A.; Freund, J.; Kieffer, S. W.
2011-05-01
Volcanic plumes on Io respresent a complex rarefied flow into a near-vacuum in the presence of gravity. A 3D Direct Simulation Monte Carlo (DSMC) method is used to investigate the gas dynamics of such plumes, with a focus on the effects of source geometry on far-field deposition patterns. A rectangular slit and a semicircular half annulus are simulated to illustrate general principles, especially the effects of vent curvature on deposition ring structure. Then two possible models for the giant plume Pele are presented. One is a curved line source corresponding to an IR image of a particularly hot region in the volcano's caldera and the other is a large area source corresponding to the entire caldera. The former is seen to produce the features seen in observations of Pele's ring, but with an error in orientation. The latter corrects the error in orientation, but loses some structure. A hybrid simulation of 3D slit flow is also discussed.
A High-Speed Spectroscopy System for Observing Lightning and Transient Luminous Events
NASA Astrophysics Data System (ADS)
Boggs, L.; Liu, N.; Austin, M.; Aguirre, F.; Tilles, J.; Nag, A.; Lazarus, S. M.; Rassoul, H.
2017-12-01
Here we present a high-speed spectroscopy system that can be used to record atmospheric electrical discharges, including lightning and transient luminous events. The system consists of a Phantom V1210 high-speed camera, a Volume Phase Holographic (VPH) grism, an optional optical slit, and lenses. The spectrograph has the capability to record videos at speeds of 200,000 frames per second and has an effective wavelength band of 550-775 nm for the first order spectra. When the slit is used, the system has a spectral resolution of about 0.25 nm per pixel. We have constructed a durable enclosure made of heavy duty aluminum to house the high-speed spectrograph. It has two fans for continuous air flow and a removable tray to mount the spectrograph components. In addition, a Watec video camera (30 frames per second) is attached to the top of the enclosure to provide a scene view. A heavy duty Pelco pan/tilt motor is used to position the enclosure and can be controlled remotely through a Rasperry Pi computer. An observation campaign has been conducted during the summer and fall of 2017 at the Florida Institute of Technology. Several close cloud-to-ground discharges were recorded at 57,000 frames per second. The spectrum of a downward stepped negative leader and a positive cloud-to-ground return stroke will be reported on.
Rapid diagnosis of acanthamoeba keratitis using non-nutrient agar with a lawn of E. coli.
Borin, Samuel; Feldman, Ilan; Ken-Dror, Shifra; Briscoe, Daniel
2013-02-27
A patient presented with a corneal foreign body in his only eye. He was treated with prophylactic antibiotics and sent home, but deteriorated. He returned to the hospital 5 days later, and on slit-lamp examination, there was ciliary injection, corneal oedema and a 1 mm × 1 mm corneal abscess with mild anterior uveitis. Corneal scrapings were taken for culture on a non-nutrient agar with a lawn of Escherichia coli, on chocolate agar and on blood agar. He was treated with fortified gentamicin and cefazolin drops. He improved and was discharged 4 days after admission. On day 5, the culture results showed acanthamoeba. He was brought back to the hospital and treated with hourly chlorhexidine drops, ofloxacin six times daily and neomycin/dexamethasone drops once daily. On day 7, he was discharged to continue treatment at home, at which time his visual acuity in that eye was 6/9, and slit-lamp examination showed punctate keratitis and a stromal opacity with mild peripheral infiltration. Culture on non-nutrient agar with a lawn of E. coli is a rapid, reliable and less invasive alternative to corneal biopsy for the diagnosis of acanthamoeba infection. We suggest using this method where acanthamoeba is suspected. Owing to the risk of corneal abscess, orthokeratology should be avoided in an amblyopic patient or an only eye. Acanthamoeba infection may be masked by other eye diseases.
Approximation for the Rayleigh Resolution of a Circular Aperture
ERIC Educational Resources Information Center
Mungan, Carl E.
2009-01-01
Rayleigh's criterion states that a pair of point sources are barely resolved by an optical instrument when the central maximum of the diffraction pattern due to one source coincides with the first minimum of the pattern of the other source. As derived in standard introductory physics textbooks, the first minimum for a rectangular slit of width "a"…
The optical design of GMOX: a next-generation instrument concept for Gemini
NASA Astrophysics Data System (ADS)
Barkhouser, Robert; Robberto, Massimo; Smee, Stephen A.; Ninkov, Zoran; Gennaro, Mario; Heckman, Timothy
2016-08-01
We present the optical design of GMOX, the Gemini Multi-Object eXtra-wide-band spectrograph. GMOX was selected as part of the Gemini Instrument Feasibility Study to develop capabilities and requirements for the next facility instrument (Gen4#3) for the observatory. We envision GMOX covering the entire optical/near-IR wavelength range accessible from the ground, from 3500 Å in the U band up to 2.4 μm in the K band, with nominal resolving power R≃5,000. To maximize efficiency, the bandpass is split into three spectrograph arms - blue, red, and near-infrared - with the near-infrared arm further split into three channels covering the Y+J, H, and K bands. At the heart of each arm is a Digital Micromirror Device (DMD) serving as a programmable slit array. This technology will enable GMOX to simultaneously acquire hundreds of spectra of faint sources in crowded fields with unparalleled spatial resolution, optimally adapting to both seeing-limited and diffraction limited conditions provided by ALTAIR and GeMS at Gemini North and South, respectively. Fed by GeMS at f/33, GMOX can synthesize slits as small as 40 mas (corresponding to a single HST/WFC3 CCD pixel) over its entire 85"x45" field of view. With either ALTAIR or the native telescope focal ratio of f/16, both the slit and field sizes double. In this paper we discuss the conceptual optical design of GMOX including, for each arm: the pre-slit optics, DMD slit array, off-axis Schmidt collimator, VPH grating, and refractive spectrograph and slit-viewing cameras.
Experimental demonstration of interferometric imaging using photonic integrated circuits.
Su, Tiehui; Scott, Ryan P; Ogden, Chad; Thurman, Samuel T; Kendrick, Richard L; Duncan, Alan; Yu, Runxiang; Yoo, S J B
2017-05-29
This paper reports design, fabrication, and demonstration of a silica photonic integrated circuit (PIC) capable of conducting interferometric imaging with multiple baselines around λ = 1550 nm. The PIC consists of four sets of five waveguides (total of twenty waveguides), each leading to a three-band spectrometer (total of sixty waveguides), after which a tunable Mach-Zehnder interferometer (MZI) constructs interferograms from each pair of the waveguides. A total of thirty sets of interferograms (ten pairs of three spectral bands) is collected by the detector array at the output of the PIC. The optical path difference (OPD) of each interferometer baseline is kept to within 1 µm to maximize the visibility of the interference measurement. We constructed an experiment to utilize the two baselines for complex visibility measurement on a point source and a variable width slit. We used the point source to demonstrate near unity value of the PIC instrumental visibility, and used the variable slit to demonstrate visibility measurement for a simple extended object. The experimental result demonstrates the visibility of baseline 5 and 20 mm for a slit width of 0 to 500 µm in good agreement with theoretical predictions.
NASA Astrophysics Data System (ADS)
Lee, Jun Ho; Hwang, Sunglyoung; Jeong, Dohwan; Hong, Jinsuk; Kim, Youngsoo; Kim, Yeonsoo; Kim, Hyunsook
2017-09-01
We report an innovative simple alignment method for a VNIR spectrometer in the wavelength region of 400-900 nm; this device is later combined with fore-optics (a telescope) to form a f/2.5 hyperspectral imaging spectrometer with a field of view of +/-7.68°. The detector at the final image plane is a 640×480 charge-coupled device with a 24 μm pixel size. We first assembled the fore-optics and the spectrometer separately and then combined them via a slit co-located on the image plane of the fore-optics and the object plane of the spectrometer. The spectrometer was assembled in three steps. In the initial step, the optics was simply assembled with an optical axis guiding He-Ne laser. In the second step, we located a pin-hole on the slit plane and a Shack-Hartmann sensor on the detector plane. The wavefront errors over the full field were scanned simply by moving the point source along the slit direction while the Shack-Hartmann sensor was constantly conjugated to the pin-hole position by a motorized stage. Optimal alignment was then performed based on the reverse sensitivity method. In the final stage, the pin-hole and the Shack-Hartmann sensor were exchanged with an equispaced 10 pin-hole slit called a field identifier and a detector. The light source was also changed from the laser (single wavelength source) to a krypton lamp (discrete multi-wavelength source). We were then easily able to calculate the distortion and keystone on the detector plane without any scanning or moving optical components; rather, we merely calculated the spectral centroids of the 10 pin-holes on the detector. We then tuned the clocking angles of the convex grating and the detector to minimize the distortion and keystone. The final assembly was tested and found to have an RMS WFE < 90 nm over the entire field of view, a keystone of 0.08 pixels, a smile of 1.13 pixels and a spectral resolution of 4.32 nm.
A Computational and Experimental Study of Resonators in Three Dimensions
NASA Technical Reports Server (NTRS)
Tam, C. K. W.; Ju, H.; Jones, Michael G.; Watson, Willie R.; Parrott, Tony L.
2009-01-01
In a previous work by the present authors, a computational and experimental investigation of the acoustic properties of two-dimensional slit resonators was carried out. The present paper reports the results of a study extending the previous work to three dimensions. This investigation has two basic objectives. The first is to validate the computed results from direct numerical simulations of the flow and acoustic fields of slit resonators in three dimensions by comparing with experimental measurements in a normal incidence impedance tube. The second objective is to study the flow physics of resonant liners responsible for sound wave dissipation. Extensive comparisons are provided between computed and measured acoustic liner properties with both discrete frequency and broadband sound sources. Good agreements are found over a wide range of frequencies and sound pressure levels. Direct numerical simulation confirms the previous finding in two dimensions that vortex shedding is the dominant dissipation mechanism at high sound pressure intensity. However, it is observed that the behavior of the shed vortices in three dimensions is quite different from those of two dimensions. In three dimensions, the shed vortices tend to evolve into ring (circular in plan form) vortices, even though the slit resonator opening from which the vortices are shed has an aspect ratio of 2.5. Under the excitation of discrete frequency sound, the shed vortices align themselves into two regularly spaced vortex trains moving away from the resonator opening in opposite directions. This is different from the chaotic shedding of vortices found in two-dimensional simulations. The effect of slit aspect ratio at a fixed porosity is briefly studied. For the range of liners considered in this investigation, it is found that the absorption coefficient of a liner increases when the open area of the single slit is subdivided into multiple, smaller slits.
Portable emittance measurement device
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liakin, D.; Seleznev, D.; Orlov, A.
2010-02-15
In Institute for Theoretical and Experimental Physics (ITEP) the portable emittance measurements device is developed. It provides emittance measurements both with ''pepper-pot'' and ''two slits'' methods. Depending on the method of measurements, either slits or pepper-pot mask with scintillator are mounted on the two activators and are installed in two standard Balzer's cross chamber with CF-100 flanges. To match the angle resolution for measured beam, the length of the stainless steel pipe between two crosses changes is adjusted. The description of the device and results of emittance measurements at the ITEP ion source test bench are presented.
Accurate color measurement methods for medical displays.
Saha, Anindita; Kelley, Edward F; Badano, Aldo
2010-01-01
The necessity for standard instrumentation and measurements of color that are repeatable and reproducible is the major motivation behind this work. Currently, different instrumentation and methods can yield very different results when measuring the same feature such as color uniformity or color difference. As color increasingly comes into play in medical imaging diagnostics, display color will have to be quantified in order to assess whether the display should be used for imaging purposes. The authors report on the characterization of three novel probes for measuring display color with minimal contamination from screen areas outside the measurement spot or from off-normal emissions. They compare three probe designs: A modified small-spot luminance probe and two conic probe designs based on black frusta. To compare the three color probe designs, spectral and luminance measurements were taken with specialized instrumentation to determine the luminance changes and color separation abilities of the probes. The probes were characterized with a scanning slit method, veiling glare, and a moving laser and LED arrangement. The scanning slit measurement was done using a black slit plate over a white line on an LCD monitor. The luminance was measured in 1 mm increments from the center of the slit to +/- 15 mm above and below the slit at different distances between the probe and the slit. The veiling glare setup consisted of measurements of the luminance of a black spot pattern with a white disk of radius of 100 mm as the black spot increases in 1 mm radius increments. The moving LED and laser method consisted of a red and green light orthogonal to the probe tip for the light to directly shine into the probe. The green light source was moved away from the red source in 1 cm increments to measure color stray-light contamination at different probe distances. The results of the color testing using the LED and laser methods suggest a better performance of one of the frusta probes at shorter distances between the light sources, which translates to less contamination. The tails of the scans indicate the magnitude of the spread in signal due to light from areas outside the intended measurement spot. The measurements indicate a corresponding glare factor for a large spot of 140, 500, and 2000 for probe A, B1, and B2, respectively. The dual-laser setup suggests that color purity can be maintained up to a few tens of millimeters outside the measurement spot. The comparison shows that there are significant differences in the performance of each probe design, and that those differences have an effect on the measured quantity used to quantify display color. Different probe designs show different measurements of the level of light contamination that affects the quantitative color determination.
Identification of the source of permanent glare from a three-piece IOL.
Wolffe, M; Landry, R J; Alpar, J J
2007-08-01
To identify the source of unwanted glare images from a three-piece intraocular lens (IOL) implant following cataract surgery. The IOL and posterior capsule were examined under mydriatic and nonmydriatic conditions using direct focal illumination from a slit lamp biomicroscope. Direct focal illumination was undertaken with both a narrow beam (0.1 mm in width) and small spot (0.1 mm in diameter) to identify the points at which the glare images were stimulated. While observing the location of the beam with the slit lamp biomicroscope, the patient indicated when the glare images were stimulated. The nasal haptic insertion into the optic was identified as the source of temporal line images arising from lights such as headlamps from oncoming cars and street lamps. The adjacent edge of the IOL was also identified as the likely source of additional cob web-like light rays. The haptic insertions in three-piece IOLs may, under certain conditions, interfere with light entering the pupil and produce extraneous images. Large mesopic pupils and decentred IOLs are conditions that increase the likelihood of unwanted glare images.
Dynamics of coherent flow structures of a pulsating unsteady glottal jet in human phonation.
NASA Astrophysics Data System (ADS)
Neubauer, Juergen; Miraghaie, Reza; Berry, David
2004-11-01
The primary sound source for human voice is oscillation of the vocal folds in the larynx. Phonation is the self-sustained oscillation of the viscoelastic vocal fold tissue driven by the air flow from the lung. It is due to the flow-induced Hopf instability of the biomechanical-aerodynamic system of vocal folds coupled to the aeroacoustic driving air flow. The aim of this study is to provide insight to the aero-acoustic part of the primary sound source of human voice. A physical rubber model of vocal folds with air flow conditions typical for human phonation was used. This model exhibits self-sustained oscillations similar to those in human phonation. The oscillating physical model can be regarded as a dynamic slit-like orifice that discharges a pulsating unsteady jet. A left-right flapping of the glottal jet axis was detected using hotwire anemometer measurements of the unsteady glottal jet. Flow visualization experiments revealed the detachment of the glottal jet from the physical model folds during the accelerating and decelerating phase of the jet pulsation. Roll-up of large-scale vortex rings as well as secondary vortex shedding in the form of Von Karman street due to shear layer instability were found downstream of the physical model.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ju, Guangxu; Highland, Matthew J.; Thompson, Carol
In anticipation of the increased use of coherent X-ray methods and the need to upgrade beamlines to match improved source quality, here the coherence properties of the X-rays delivered by beamline 12ID-D at the Advanced Photon Source have been characterized. The measured X-ray divergence, beam size, brightness and coherent flux at energies up to 26 keV are compared with the calculated values from the undulator source, and the effects of beamline optics such as a mirror, monochromator and compound refractive lenses are evaluated. Diffraction patterns from slits as a function of slit width are analyzed using wave propagation theory tomore » obtain the beam divergence and thus coherence length. Imaging of the source using a compound refractive lens was found to be the most accurate method for determining the vertical divergence. While the brightness and coherent flux obtained without a monochromator ('pink beam') agree well with those calculated for the source, those measured with the monochromator were a factor of three to six lower than the source, primarily because of vertical divergence introduced by the monochromator. As a result, the methods described herein should be widely applicable for measuring the X-ray coherence properties of synchrotron beamlines.« less
Ju, Guangxu; Highland, Matthew J.; Thompson, Carol; ...
2018-06-13
In anticipation of the increased use of coherent X-ray methods and the need to upgrade beamlines to match improved source quality, here the coherence properties of the X-rays delivered by beamline 12ID-D at the Advanced Photon Source have been characterized. The measured X-ray divergence, beam size, brightness and coherent flux at energies up to 26 keV are compared with the calculated values from the undulator source, and the effects of beamline optics such as a mirror, monochromator and compound refractive lenses are evaluated. Diffraction patterns from slits as a function of slit width are analyzed using wave propagation theory tomore » obtain the beam divergence and thus coherence length. Imaging of the source using a compound refractive lens was found to be the most accurate method for determining the vertical divergence. While the brightness and coherent flux obtained without a monochromator ('pink beam') agree well with those calculated for the source, those measured with the monochromator were a factor of three to six lower than the source, primarily because of vertical divergence introduced by the monochromator. As a result, the methods described herein should be widely applicable for measuring the X-ray coherence properties of synchrotron beamlines.« less
Hössl, Bernhard; Böhm, Helmut J; Rammerstorfer, Franz G; Barth, Friedrich G
2007-04-01
Arachnid strain sensitive slit sensilla are elongated openings in the cuticle with aspect ratios (slit length l/slit width b) of up to 100. Planar Finite Element (FE) models are used to calculate the relative slit face displacements, Dc, at the centers of single slits and of arrangements of mechanically interacting slits under uni-axial compressive far-field loads. Our main objective is to quantitatively study the role of the following geometrical parameters in stimulus transformation: aspect ratio, slit shape, geometry of the slits' centerlines, load direction, lateral distance S, longitudinal shift lambda, and difference in slit length Deltal between neighboring slits. Slit face displacements are primarily sensitive to slit length and load direction but little affected by aspect ratios between 20 and 100. In stacks of five parallel slits at lateral distances typical of lyriform organs (S=0.03 l) the longitudinal shift lambda substantially influences slit compression. A change of lambda from 0 to 0.85 l causes changes of up to 420% in Dc. Even minor morphological variations in the arrangements can substantially influence the stimulus transformation. The site of transduction in real slit sensilla does not always coincide with the position of maximum slit compression predicted by simplified models.
Galaxy evolution spectroscopic explorer: scientific rationale
NASA Astrophysics Data System (ADS)
Heap, Sara; Ninkov, Zoran; Robberto, Massimo; Hull, Tony; Purves, Lloyd
2016-07-01
GESE is a mission concept consisting of a 1.5-m space telescope and UV multi-object slit spectrograph designed to help understand galaxy evolution in a critical era in the history of the universe, where the rate of star-formation stopped increasing and started to decline. To isolate and identify the various processes driving the evolution of these galaxies, GESE will obtain rest-frame far-UV spectra of 100,000 galaxies at redshifts, z 1-2. To obtain such a large number of spectra, multiplexing over a wide field is an absolute necessity. A slit device such as a digital micro-mirror device (DMD) or a micro-shutter array (MSA) enables spectroscopy of a hundred or more sources in a single exposure while eliminating overlapping spectra of other sources and blocking unwanted background like zodiacal light. We find that a 1.5-m space telescope with a MSA slit device combined with a custom orbit enabling long, uninterrupted exposures ( 10 hr) are optimal for this spectroscopic survey. GESE will not be operating alone in this endeavor. Together with x-ray telescopes and optical/near-IR telescopes like Subaru/Prime Focus Spectrograph, GESE will detect "feedback" from young massive stars and massive black holes (AGN's), and other drivers of galaxy evolution.
Galaxy Evolution Spectroscopic Explorer: Scientific Rationale
NASA Technical Reports Server (NTRS)
Heap, Sara; Ninkov, Zoran; Robberto, Massimo; Hull, Tony; Purves, Lloyd
2016-01-01
GESE is a mission concept consisting of a 1.5-m space telescope and UV multi-object slit spectrograph designed to help understand galaxy evolution in a critical era in the history of the universe, where the rate of star-formation stopped increasing and started to decline. To isolate and identify the various processes driving the evolution of these galaxies, GESE will obtain rest-frame far-UV spectra of 100,000 galaxies at redshifts, z approximately 1-2. To obtain such a large number of spectra, multiplexing over a wide field is an absolute necessity. A slit device such as a digital micro-mirror device (DMD) or a micro-shutter array (MSA) enables spectroscopy of a hundred or more sources in a single exposure while eliminating overlapping spectra of other sources and blocking unwanted background like zodiacal light. We find that a 1.5-m space telescope with a MSA slit device combined with a custom orbit enabling long, uninterrupted exposures (approximately 10 hr) are optimal for this spectroscopic survey. GESE will not be operating alone in this endeavor. Together with x-ray telescopes and optical/near-IR telescopes like Subaru/Prime Focus Spectrograph, GESE will detect "feedback" from young massive stars and massive black holes (AGN's), and other drivers of galaxy evolution.
NASA Astrophysics Data System (ADS)
Onaka, Takashi; Mori, Tamami; Sakon, Itsuki; Ardaseva, Aleksandra
2016-10-01
We present the results of near-infrared (2.5-5.4 μm) long-slit spectroscopy of the extended green object (EGO) G318.05+0.09 with AKARI. Two distinct sources are found in the slit. The brighter source has strong red continuum emission with H2O ice, CO2 ice, and CO gas and ice absorption features at 3.0, 4.25 μm, 4.67 μm, respectively, while the other greenish object shows peculiar emission that has double peaks at around 4.5 and 4.7 μm. The former source is located close to the ultra compact H II region IRAS 14498-5856 and is identified as an embedded massive young stellar object (YSO). The spectrum of the latter source can be interpreted by blueshifted (-3000 ˜ -6000 km s-1) optically thin emission of the fundamental ro-vibrational transitions (v=1{--}0) of CO molecules with temperatures of 12000-3700 K without noticeable H2 and H I emission. We discuss the nature of this source in terms of outflow associated with the young stellar object and supernova ejecta associated with a supernova remnant.
Space and time resolved representation of a vacuum arc light emission
NASA Astrophysics Data System (ADS)
Georgescu, N.; Sandolache, G.; Zoita, V.
1999-04-01
An optoelectronic multichannel detection system for the study of the visible light emission of a vacuum circuit breaker arc is described. The system consists of two multiple slit collimator assemblies coupled directly to the arc discharge chamber and an electronic detection part. The light emitted by the arc is collected by the two collimator assemblies and is transmitted through optical fibres to the electronic detection part. By using a new, simple computational method two-dimensional plots of the vacuum arc light emission at different times are obtained.
Development of a compact E ? B microchannel plate detector for beam imaging
Wiggins, B. B.; Singh, Varinderjit; Vadas, J.; ...
2017-06-17
A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E×B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in one-dimension. To assess the spatial resolution, the detector was illuminated by an α-source with an intervening mask that consists of a series of precisely-machined slits. The measured spatial resolution was 520 um source FWHM, which was improved to 413 um FWHM by performing an FFT of the signals, rejecting spurious signals on the delay line, and requiring a minimum signal amplitude. This measured spatialmore » resolution of 413 um FWHM corresponds to an intrinsic resolution of 334 um FWHM when the effect of the finite slit width is de-convoluted. To understand the measured resolution, the performance of the detector is simulated with the ion-trajectory code SIMION.« less
Development of a compact E ? B microchannel plate detector for beam imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wiggins, B. B.; Singh, Varinderjit; Vadas, J.
A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E×B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in one-dimension. To assess the spatial resolution, the detector was illuminated by an α-source with an intervening mask that consists of a series of precisely-machined slits. The measured spatial resolution was 520 um source FWHM, which was improved to 413 um FWHM by performing an FFT of the signals, rejecting spurious signals on the delay line, and requiring a minimum signal amplitude. This measured spatialmore » resolution of 413 um FWHM corresponds to an intrinsic resolution of 334 um FWHM when the effect of the finite slit width is de-convoluted. To understand the measured resolution, the performance of the detector is simulated with the ion-trajectory code SIMION.« less
Boundary-Layer Effects on Acoustic Transmission Through Narrow Slit Cavities.
Ward, G P; Lovelock, R K; Murray, A R J; Hibbins, A P; Sambles, J R; Smith, J D
2015-07-24
We explore the slit-width dependence of the resonant transmission of sound in air through both a slit array formed of aluminum slats and a single open-ended slit cavity in an aluminum plate. Our experimental results accord well with Lord Rayleigh's theory concerning how thin viscous and thermal boundary layers at a slit's walls affect the acoustic wave across the whole slit cavity. By measuring accurately the frequencies of the Fabry-Perot-like cavity resonances, we find a significant 5% reduction in the effective speed of sound through the slits when an individual viscous boundary layer occupies only 5% of the total slit width. Importantly, this effect is true for any airborne slit cavity, with the reduction being achieved despite the slit width being on a far larger scale than an individual boundary layer's thickness. This work demonstrates that the recent prevalent loss-free treatment of narrow slit cavities within acoustic metamaterials is unrealistic.
Negative ion source with low temperature transverse divergence optical system
Whealton, John H.; Stirling, William L.
1986-01-01
A negative ion source is provided which has extremely low transverse divergence as a result of a unique ion focusing system in which the focal line of an ion beam emanating from an elongated, concave converter surface is outside of the ion exit slit of the source and the path of the exiting ions. The beam source operates with a minimum ion temperature which makes possible a sharply focused (extremely low transverse divergence) ribbon like negative ion beam.
Negative ion source with low temperature transverse divergence optical system
Whealton, J.H.; Stirling, W.L.
1985-03-04
A negative ion source is provided which has extremely low transverse divergence as a result of a unique ion focusing system in which the focal line of an ion beam emanating from an elongated, concave converter surface is outside of the ion exit slit of the source and the path of the exiting ions. The beam source operates with a minimum ion temperature which makes possible a sharply focused (extremely low transverse divergence) ribbon like negative ion beam.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Englbrecht, F; Lindner, F; Bin, J
2016-06-15
Purpose: To measure and simulate well-defined electron spectra using a linear accelerator and a permanent-magnetic wide-angle spectrometer to test the performance of a novel reconstruction algorithm for retrieval of unknown electron-sources, in view of application to diagnostics of laser-driven particle acceleration. Methods: Six electron energies (6, 9, 12, 15, 18 and 21 MeV, 40cm × 40cm field-size) delivered by a Siemens Oncor linear accelerator were recorded using a permanent-magnetic wide-angle electron spectrometer (150mT) with a one dimensional slit (0.2mm × 5cm). Two dimensional maps representing beam-energy and entrance-position along the slit were measured using different scintillating screens, read by anmore » online CMOS detector of high resolution (0.048mm × 0.048mm pixels) and large field of view (5cm × 10cm). Measured energy-slit position maps were compared to forward FLUKA simulations of electron transport through the spectrometer, starting from IAEA phase-spaces of the accelerator. The latter ones were validated against measured depth-dose and lateral profiles in water. Agreement of forward simulation and measurement was quantified in terms of position and shape of the signal distribution on the detector. Results: Measured depth-dose distributions and lateral profiles in the water phantom showed good agreement with forward simulations of IAEA phase-spaces, thus supporting usage of this simulation source in the study. Measured energy-slit position maps and those obtained by forward Monte-Carlo simulations showed satisfactory agreement in shape and position. Conclusion: Well-defined electron beams of known energy and shape will provide an ideal scenario to study the performance of a novel reconstruction algorithm using measured and simulated signal. Future work will increase the stability and convergence of the reconstruction-algorithm for unknown electron sources, towards final application to the electrons which drive the interaction of TW-class laser pulses with nanometer thin target foils to accelerate protons and ions to multi-MeV kinetic energy. Cluster of Excellence of the German Research Foundation (DFG) “Munich-Centre for Advanced Photonics”.« less
Directional spectral emissivity measurement system
NASA Technical Reports Server (NTRS)
Halyo, Nesim (Inventor); Pandey, Dhirendra K. (Inventor)
1992-01-01
Apparatus and process for determining the emissivity of a test specimen including an integrated sphere having two concentric walls with a coolant circulating therebetween, and disposed within a chamber which may be under ambient, vacuum or inert gas conditions. A reference sample is disposed within the sphere with a monochromatic light source in optical alignment therewith. A pyrometer is in optical alignment with the test sample for obtaining continuous test sample temperature measurements during a test. An arcuate slit port is provided through the spaced concentric walls of the integrating sphere with a movable monochromatic light source extending through and movable along the arcuate slit port. A detector system extends through the integrating sphere for continuously detecting an integrated signal indicative of all radiation within its field of view, as a function of the emissivity of the test specimen at various temperatures and various angle position of the monochromatic light source. A furnace for heating the test sample to approximately 3000 K. and control mechanism for transferring the heated sample from the furnace to the test sample port in the integrating sphere is also contained within the chamber.
Coherence Length and Vibrations of the Coherence Beamline I13 at the Diamond Light Source
NASA Astrophysics Data System (ADS)
Wagner, U. H.; Parson, A.; Rau, C.
2017-06-01
I13 is a 250 m long hard x-ray beamline for imaging and coherent diffraction at the Diamond Light Source. The beamline (6 keV to 35 keV) comprises two independent experimental endstations: one for imaging in direct space using x-ray microscopy and one for imaging in reciprocal space using coherent diffraction based imaging techniques [1]. In particular the coherence experiments pose very high demands on the performance on the beamline instrumentation, requiring extensive testing and optimisation of each component, even during the assembly phase. Various aspects like the quality of optical components, the mechanical design concept, vibrations, drifts, thermal influences and the performance of motion systems are of particular importance. In this paper we study the impact of the front-end slit size (FE slit size), which determines the horizontal source size, onto the coherence length and the detrimental impact of monochromator vibrations using in-situ x-ray metrology in conjunction with fringe visibility measurements and vibration measurements, based on centroid tracking of an x-ray pencil beam with a photon-counting detector.
Braisted, Janet E; Ringstedt, Thomas; O'Leary, Dennis D M
2009-07-01
Thalamocortical axons (TCAs) originate in dorsal thalamus, extend ventrally along the lateral thalamic surface, and as they approach hypothalamus make a lateral turn into ventral telencephalon. In vitro studies show that hypothalamus releases a chemorepellent for TCAs, and analyses of knockout mice indicate that Slit chemorepellents and their receptor Robo2 influence TCA pathfinding. We show that Slit chemorepellents are the hypothalamic chemorepellent and act through Robos to steer TCAs into ventral telencephalon. During TCA pathfinding, Slit1 and Slit2 are expressed in hypothalamus and ventral thalamus and Robo1 and Robo2 are expressed in dorsal thalamus. In collagen gel cocultures of dorsal thalamus and Slit2-expressing cells, axon number and length are decreased on the explant side facing Slit2-expressing cells, overall axon outgrowth is diminished, and axons turn away from the Slit2-expressing cells. Thus, Slit2 is an inhibitor and chemorepellent for dorsal thalamic axons. Collagen gel cocultures of dorsal thalamus with sections of live diencephalon, with and without the hypothalamus portion overlaid with Robo2-fc-expressing cells to block Slit function, identify Slits as the hypothalamic chemorepellent. Thus, Slits are chemorepellents for TCAs endogenous to hypothalamus and steer TCAs from diencephalon into ventral telencephalon, a critical pathfinding event defective in Slit and Robo2 mutant mice.
Experimental comparison of various techniques for spot size measurement of high-energy X-ray
NASA Astrophysics Data System (ADS)
Wang, Yi; Li, Qin; Chen, Nan; Cheng, Jin-Ming; Li, Cheng-Gang; Li, Hong; Long, Quan-Hong; Shi, Jin-Shui; Deng, Jian-Jun
2016-08-01
In flash-radiography experiments, the quality of the acquired image strongly depends on the focal size of the X-ray source spot. A variety of techniques based on imaging of the pinhole, the slit and the rollbar are adopted to measure the focal spot size of the Dragon-I linear induction accelerator. The image of the pinhole provides a two-dimensional distribution of the X-ray spot, while those of the slit and the rollbar give a line-spread distribution and an edge-spread distribution, respectively. The spot size characterized by the full-width at half-maximum and that characterized by the LANL definition are calculated for comparison.
Pulsed Discharge Nozzle Cavity Ring Down Spectroscopy of Cold PAH Ions
NASA Technical Reports Server (NTRS)
Biennier, Ludovic; Salama, Farid; Allamandola, Louis J.; Scherer, James J.; DeVincenzi, Donald (Technical Monitor)
2002-01-01
The gas-phase electronic absorption spectra of the naphthalene (C10H8(+)) and acenaphthene (C12H10(+)) cations have been measured in the visible range in a free 10 jet planar expansion in an attempt to collect data in an astrophysically relevant environment. The direct absorption spectra of two out of four bands measured of the gas-phase cold naphthalene cation along with the gas-phase vibronic absorption spectrum of the cold acenaphthene cation are reported for the first time. The study has been carried out using the ultrasensitive and versatile technique of cavity ringdown spectroscopy (CRDS) coupled to a pulsed discharge slit nozzle (PDN). The new CRDS-PDN set up is described and its characteristics are evaluated. The direct-absorption spectra of the PAH ions are discussed and compared to the gas-phase and solid-phase data available in the literature. The analysis of the results show that cold, free flying PAH ions are generated in the argon discharge primarily through soft Penning ionization. This enables the intrinsic band profiles to be measured, a key requirement for astrophysical applications.
Tanabe, N; Go, K; Sakurada, Y; Imasawa, M; Mabuchi, F; Chiba, T; Abe, K; Kashiwagi, K
2011-01-01
To develop a remote-operating slit lamp microscope system (the remote slit lamp) as the core for highly specialized ophthalmology diagnoses, and to compare the utility of this system with the conventional slit lamp microscope system (the conventional slit lamp) in making a diagnosis. The remote slit lamp system was developed. Three factors were evaluated in comparison to the conventional slit lamp. The ability to acquire skills was investigated using a task loading system among specialists and residents in ophthalmology. Participants repeated a task up to ten times and the time required for each task was analyzed. The consistency of the two systems in making a diagnosis was investigated using eyes of patients with ocular diseases as well as healthy volunteers. The remote slit lamp is composed of a patient's unit and ophthalmologist's unit connected by high-speed internet. The two units share images acquired by the slit lamp in addition to the images and voices of patients and ophthalmologists. Both ophthalmology specialists and residents could minimize the completion times after several trials. The remote slit lamp took more time than the conventional slit lamp. Both systems showed a high consistency in evaluations among eyes with healthy eyes or those with ocular diseases. The remote slit lamp has a similar diagnostic ability, but required more examination time in comparison to the conventional slit lamp. The currently developed remote slit lamp has the potential to be employed for tele-medicine purposes in the field of ophthalmology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, He; Yuan, Ping; Cen, Jian-Yong
2014-03-15
A cloud-to-ground lightning with six return strokes has been recorded with a slit-less spectrograph in Qinghai province. According to the spectra of return strokes without continuous current, the electron density, the channel temperature, and the gas pressure have been calculated. Then, the correlativity of these parameters has been analyzed. The results indicate that the total intensity of spectra is positive correlated to the intensity of spectral line, they both decrease with time rapidly; furthermore, the channel temperature and the gas pressure decrease with time slowly in the similar trends.
Determination Of Slitting Criterion Parameter During The Multi Slit Rolling Process
NASA Astrophysics Data System (ADS)
Stefanik, Andrzej; Mróz, Sebastian; Szota, Piotr; Dyja, Henryk
2007-05-01
The rolling of rods with slitting of the strip calls for the use of special mathematical models that would allow for the separating of metal. A theoretical analysis of the effect of the gap of slitting rollers on the process of band slitting during the rolling of 20 mm and 16 mm-diameter ribbed rods rolled according to the two-strand technology was carried out within this study. For the numerical modeling of strip slitting the Forge3® computer program was applied. The strip slitting in the simulation is implemented by the algorithm of removing elements in which the critical value of the normalized Cockroft - Latham criterion has been exceeded. To determine the value of the criterion the inverse method was applied. Distance between a point, where crack begins, and point of contact metal with the slitting rollers was the parameter for analysis. Power and rolling torque during slit rolling were presented. Distribution and change of the stress in strand while slitting were presented.
NASA Astrophysics Data System (ADS)
Mihara, T.; Maxi Team
2010-12-01
Gas Slit Camera (GSC) is the instrument in the MAXI mission. The GSC utilizes twelve large area proportional counters (PC), a slit and slats collimator. The energy range is 2-30 keV. The GSC has two FOVs of 160 x 3 degrees. One is toward forward direction of ISS and the other is the zenithal direction. Two arches of FOV scans the sky in every 92 minutes with ISS rotation. The slats collimator makes the narrow arc FOV, and the one-dimensional position-resolution of the PC resolves the X-ray sources within the FOV. Thus the position resolution is determined by the slats collimator and a combination of the slit and the position resolution of the detector. These make the point spread function of 1.5 x 1.5 degrees. The background is 1.2 × 10^-4 c/s/cm2 /keV, which is almost the same level with Ginga/LAC. The 5-sigma sensitivity is 15 mCrab/day, which is improved to with the sqrt (t) law. It will reach the 5 sigma confusion limit of 0.5 mCrab in 900 days, if the particle-background estimation is accurate enough.
Phonon Conduction in Silicon Nanobeam Labyrinths
Park, Woosung; Romano, Giuseppe; Ahn, Ethan C.; ...
2017-07-24
Here we study single-crystalline silicon nanobeams having 470 nm width and 80 nm thickness cross section, where we produce tortuous thermal paths (i.e. labyrinths) by introducing slits to control the impact of the unobstructed “line-of-sight” (LOS) between the heat source and heat sink. The labyrinths range from straight nanobeams with a complete LOS along the entire length to nanobeams in which the LOS ranges from partially to entirely blocked by introducing slits, s = 95, 195, 245, 295 and 395 nm. The measured thermal conductivity of the samples decreases monotonically from ~47 W m -1K -1 for straight beam tomore » ~31 W m -1 K -1 for slit width of 395 nm. A model prediction through a combination of the Boltzmann transport equation and ab initio calculations shows an excellent agreement with the experimental data to within ~8%. The model prediction for the most tortuous path (s = 395 nm) is reduced by ~14% compared to a straight beam of equivalent cross section. This study suggests that LOS is an important metric for characterizing and interpreting phonon propagation in nanostructures.« less
Micromechanical slit positioning system as a transmissive spatial light modulator
NASA Astrophysics Data System (ADS)
Riesenberg, Rainer
2001-11-01
Micro-slits have been prepared with a slit-width and a slit- length of 2 ... 1000 micrometers . Linear and two-dimensional arrays up to 10 x 110 slits have been developed and completed with a piezo-actuator for shifting. This system is a so-called mechanical slit positioning system. The light is switched by simple one- or two-dimensional displacement of coded slit masks in a one- or two-layer architecture. The slit positioning system belongs to the transmissive class of MEMS-based spatial light modulators (SLM). It has fundamental advantages for optical contrast and also can be used in the full spectral region. Therefore transmissive versions of SLM should be a future solution. Instrument architectures based on the slit positioning system can increase the resolution by subpixel generation, the throughput by HADAMARD transform mode, or select objects for multi-object-spectroscopy. The linear slit positioning system was space qualified within an advanced micro- spectrometer. A NIR multi-object-spectrometer for the Next Generation Space Telescope (NGST) is based on a field selector for selecting objects. The field selector is a SLM, which could be implemented by a slit positioning system.
Penning discharge ion source with self-cleaning aperture
Gavin, Basil F.; MacGill, Robert A.; Thatcher, Raymond K.
1982-01-01
An ion source of the Penning discharge type having a self-cleaning aperture is provided by a second dynode (24) with an exit aperture (12) in a position opposite a first dynode 10a, from which the ions are sputtered, two opposing cathodes (14, 16), each with an anode (18, 20) for accelerating electrons emitted from the cathodes into a cylindrical space defined by the first and second dynode. A support gas maintained in this space is ionized by the electrons. While the cathodes are supplied with a negative pulse to emit electrons, the first dynode is supplied with a negative pulse (e.g., -300 V) to attract atoms of the ionized gas (plasma). At the same time, the second dynode may also be supplied with a small voltage that is negative with respect to the plasma (e.g., -5 V) for tuning the position of the plasma miniscus for optimum extraction geometry. When the negative pulse to the first dynode is terminated, the second dynode is driven strongly negative (e.g., -600 V) thereby allowing heavy sputtering to take place for a short period to remove virtually all of the atoms deposited on the second dynode from material sputtered off the first dynode. An extractor (22) immediately outside the exit aperture of the second dynode is maintained at ground potential during this entire period of sputtering while the anode, dynode and cathode reference voltage is driven strongly positive (about +20 kV to +30 kV) so that ions accelerated through the aperture will be at ground potential. In that manner, material from the first dynode deposited on the second dynode will be sputtered, in time, to add to the ion beam. Atoms sputtered from the second dynode which do not become ionized and exit through the slit will be redeposited on the first dynode, and hence recycled for further ion beam generation during subsequent operating cycles.
Passive control of base pressure on an axisymmetric blunt body using a perimetric slit
NASA Astrophysics Data System (ADS)
García de la Cruz, Juan Marcos; Oxlade, Anthony R.; Morrison, Jonathan F.
2017-04-01
The effect on the base pressure of a thin slit located at the base edge of a blunt axisymmetric body, communicating an internal cavity with the external flow, is investigated. A parametric study is performed of the effect on base pressure of changes in slit size and cavity depth. The base pressure increases initially with increasing cavity depth, but saturates at a depth which depends on the slit size. The base pressure increases monotonically up to 5 % with increasing slit size for the geometries tested. An upper limit of base pressure recovery of 20 % is extrapolated from the data. It is observed that the main effect of the slit is to reduce the instantaneous pressure asymmetry, which is linked to the total base pressure in a similar fashion for all the slit sizes. As a second-order effect, for highly asymmetric pressure distributions, the slit produces a base pressure increase not associated with the base pressure asymmetry. The results suggest a global effect of the slit on the wake due to a diametrical flow within the cavity driven by the pressure differences across the slit and regulated by the largest of the pressure drops between the slit and cavity. The slit also reduces the periodic base pressure fluctuations, corresponding mainly to the vortex shedding, and increases the rotational speed of the wake.
Slit2 signaling through Robo1 and Robo2 is required for retinal neovascularization
Rama, Nicolas; Dubrac, Alexandre; Mathivet, Thomas; Chárthaigh, Róisín-Ana Ní; Genet, Gael; Cristofaro, Brunella; Pibouin-Fragner, Laurence; Ma, Le; Eichmann, Anne; Chédotal, Alain
2016-01-01
Ocular neovascular diseases are a leading cause of blindness. Vascular endothelial growth factor (VEGF) blockade improves vision, but not all individuals respond to anti-VEGF treatment, making additional means to prevent neovascularization necessary. Slit-family proteins (Slits) are ligands of Roundabout (Robo) receptors that repel developing axons in the nervous system. Robo1 expression is altered in ocular neovascular diseases, and previous in vitro studies have reported both pro- and anti-angiogenic effects of Slits. However, genetic evidence supporting a role for Slits in ocular neovascularization is lacking. Here we generated conditional knockout mice deficient in various Slit and Robo proteins and found that Slit2 potently and selectively promoted angiogenesis via Robo1 and Robo2 in mouse postnatal retina and in a model of ocular neovascular disease. Mechanistically, Slit2 acting through Robo1 and Robo2 promoted the migration of endothelial cells. These receptors are required for both Slit2- and VEGF-induced Rac1 activation and lamellipodia formation. Thus, Slit2 blockade could potentially be used therapeutically to inhibit angiogenesis in individuals with ocular neovascular disease. PMID:25894826
Oppenheimer, F.F.
1959-06-01
A calutron ion source is described which masks the ends of the arc to provide a more stable beam from the middle portion. The masking is effected by milling the arc slit in a single sheet of material which is secured to the open face of the arc block. (T.R.H.)
Geometrical optics modeling of the grating-slit test.
Liang, Chao-Wen; Sasian, Jose
2007-02-19
A novel optical testing method termed the grating-slit test is discussed. This test uses a grating and a slit, as in the Ronchi test, but the grating-slit test is different in that the grating is used as the incoherent illuminating object instead of the spatial filter. The slit is located at the plane of the image of a sinusoidal intensity grating. An insightful geometrical-optics model for the grating-slit test is presented and the fringe contrast ratio with respect to the slit width and object-grating period is obtained. The concept of spatial bucket integration is used to obtain the fringe contrast ratio.
Zhou, Weiyan; Wang, Hongya; Yu, Wenzhen; Xie, Wankun; Zhao, Min; Huang, Lvzhen; Li, Xiaoxin
2017-01-01
The Slit-Robo signal has an important role in vasculogenesis and angiogenesis. Our study examined the expression of Slit2 and its receptor, Robo1, in a rat model of streptozotocin-induced diabetes and in patients with proliferative diabetic retinopathy. Diabetes was induced in male Sprague-Dawley rats via a single, intraperitoneal injection of streptozotocin. The rats were sacrificed 1, 3 or 6 months after the injection. The expression of Slit2 and Robo1 in retinal tissue was measured by real-time reverse transcription polymerase chain reaction (RT-PCR), and protein levels were measured by western blotting and immunohistochemistry. Recombinant N-Slit2 protein was used to study the effects of Slit2 on the expression of VEGF in vivo. The concentration of Slit2 protein in human eyes was measured by enzyme-linked immunosorbent assay in 27 eyes with proliferative diabetic retinopathy and 28 eyes in control group. The expression of Slit2, Robo1 and VEGF in the excised human fibrovascular membranes was examined by fluorescence immunostaining and semi-quantitative RT-PCR. The expression of Slit2 and Robo1 in the retina was altered after STZ injection. Recombinant N-Slit2 protein did not increase the retinal VEGF expression. Vitreous concentrations of Slit2 were significantly higher in the study group than in the control group. In the human fibrovascular membranes of the study group, the co-localization of VEGF with the markers for Slit2 and Robo1was observed. The expression of Slit2 mRNA, Robo1 mRNA, and VEGF mRNA was significantly higher in human fibrovascular proliferative diabetic retinopathy membranes than in the control membranes. The alteration of Slit2 and Robo1 expression in the retinas of diabetic rats and patients with proliferative diabetic retinopathy suggests a role for the Slit-Robo signal in the various stages diabetic retinopathy. Further studies should address the possible involvement of the Slit-Robo signal in the pathophysiological progress of diabetic retinopathy.
Liu, Dong; Xiao, Yan; Subramanian, Romesh R.; Okamoto, Ei-ichi; Wilcox, Josiah N.; Anderson, Leonard; De Leon, Hector
2016-01-01
Leukocyte infiltration of adventitial and perivascular tissues is an early event in the development of vascular remodeling after injury. We investigated whether Slit/Robo—an axonal chemorepellent system in vertebrate and invertebrate development—is activated during the inflammatory phase that follows endothelial denudation. Using the rat carotid artery model of angioplasty, we conducted a time course analysis of mRNAs encoding Slit ligands (Slit2 and Slit3) and Robo receptors (Robo1, Robo2 and Robo4), as well as proinflammatory cell adhesion molecule (CAM) genes. Adventitial inflammatory cells were counted in immunostained arterial sections. E-selectin, vascular CAM-1 (VCAM-1), and intercellular CAM-1 (ICAM-1) were upregulated 2–3 hr after injury, followed by infiltration of neutrophils and monocytes as evidenced by real-time PCR, in situ hybridization, and immunohistochemistry. Slit2, Slit3, and Robo genes exhibited no expression changes at 3 hr; however, they were markedly upregulated 1 day after angioplasty. ICAM-1 expression was reduced by 50%, and the number of adventitial neutrophils decreased by >75% one day after angioplasty. Slit2 has been shown to be a potent chemorepelent of leukocytes, endothelial cells and smooth muscle cells. Thus, we decided to further investigate the localization of Slit2 in injured vessels. Immunohistochemical stainings revealed the presence of Slit2 within the vessel wall and in the perivascular vasa vasorum of naive and injured arteries. Double immunohistochemical analyses showed that infiltrating monocytes expressed Slit2 in the perivascular and adventitial tissues of injured arteries 1 and 3 days postangioplasty. In addition, recombinant full-length Slit2 and Slit2-N/1118, an N-terminal fragment of Slit2, inhibited stromal cell-derived factor 1 (SDF-1)-mediated migration of circulating rat peripheral blood mononuclear cells. In summary, adventitial activation of CAM genes and neutrophil infiltration preceded upregulation of Slit/Robo genes. Sli2 expression colocalized with infiltrating inflammatory cells in the adventitial layer. This temporospatial association suggests that leukocyte chemorepellent Slit2 may be involved in halting the adventitial accumulation of inflammatory cells in injured vessels. PMID:26841069
Epinephrine Use in Clinical Trials of Sublingual Immunotherapy Tablets.
Nolte, Hendrik; Casale, Thomas B; Lockey, Richard F; Fogh, Bodil Svanholm; Kaur, Amarjot; Lu, Susan; Nelson, Harold S
Allergy immunotherapy can result in systemic allergic reactions and even life-threatening anaphylaxis requiring epinephrine administration. The objective of this study was to describe epinephrine use in the clinical trial development programs of 3 rapidly dissolving sublingual immunotherapy tablets (SLIT-tablets; Merck & Co., Inc., Kenilworth, NJ/ALK, Hørsholm, Denmark/Torii Pharmaceutical Co., Ltd., Tokyo, Japan). Data on epinephrine use were collected from 13 timothy grass SLIT-tablet trials (MK-7243; ≤2800 bioequivalent allergen units/75,000 SQ-T dose, n = 2497; placebo, n = 2139), 5 short ragweed SLIT-tablet trials (MK-3641; ≤12 Amb a 1-U, n = 1725; placebo, n = 770), and 11 house dust mite (HDM) SLIT-tablet trials (MK-8237; ≤12 SQ-HDM; n = 3930; placebo, n = 2246). In grass SLIT-tablet trials, epinephrine was used 13 times (grass SLIT-tablet, n = 10; placebo, n = 3). Eight administrations were for grass SLIT-tablet-related adverse events (AEs): 4 for systemic allergic reactions and 4 for local mouth and/or throat swelling. In ragweed SLIT-tablet trials, epinephrine was used 9 times in 8 subjects (ragweed SLIT-tablet, n = 7; placebo, n = 1 [2 administrations for protracted anaphylaxis]). Four administrations were for ragweed SLIT-tablet-related AEs: 1 for systemic allergic reaction and 3 for local mouth and/or pharynx/throat swelling. In HDM SLIT-tablet trials, epinephrine was administered 13 times (HDM SLIT-tablet, n = 8; placebo, n = 5). Four administrations were for HDM SLIT-tablet-related AEs: 1 for systemic allergic reaction and 3 for local events. Of the 16 epinephrine administrations for events related to SLIT-tablet treatment, 11 occurred within the first week of treatment (7 administrations on day 1) and 5 were subject self-administered. Epinephrine administrations in response to SLIT-tablet-related reactions in clinical trials are uncommon, typically occur within the first week of treatment, and are rarely self-administered. All SLIT-tablet-related events treated with epinephrine were nonserious. Copyright © 2016 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Grimshaw, R. H. J.; Baines, P. G.; Bell, R. C.
1985-07-01
We consider the three-dimensional reflection and diffraction properties of internal waves in a continuously stratified rotating fluid which are incident on the junction of a vertical slit and a half-space. This geometry is a model for submarine canyons on continental slopes in the ocean, where various physical phenomena embodying reflection and diffraction effects have been observed. Three types of incident wave are considered: (1) Kelvin waves in the slit (canyon); (2) Kelvin waves on the slope; and (3) plane internal waves incident from the half-space (ocean). These are scattered into Kelvin and Poincaré waves in the slit, a Kelvin wave on the slope and Poincaré waves in the half-space. Most of the discussion is centered around case (1). Various properties of the wave field are calculated for ranges of the parameters c/ cot θ, γα and ƒ/ω where cot θ is the topographic slope, c is the internal wave ray slope, α is the canyon half-width, γ is the down-slope wave-number, ƒ is the Coriolis parameter and ω is the wave frequency. Analytical results are obtained for small γα and some approximate results for larger values of γα. The results show that significant wave trapping may occur in oceanic situations, and that submarine canyons may act as source regions for internal Kelvin waves on the continental slope.
USDA-ARS?s Scientific Manuscript database
SLIT guidance ligands are secreted glycoproteins involved in organogenesis. SLIT proteins and their receptor have been linked to ovarian development in fetal sheep and luteal function in adult humans. In pigs, SLIT proteins have been associated with age at puberty (GWAS) and as a major node in genom...
Relation between one- and two-dimensional noise power spectra of magnetic resonance images.
Ichinoseki, Yuki; Machida, Yoshio
2017-06-01
Our purpose in this study was to elucidate the relation between the one-dimensional (1D) and two-dimensional (2D) noise power spectra (NPSs) in magnetic resonance imaging (MRI). We measured the 1D NPSs using the slit method and the radial frequency method. In the slit method, numerical slits 1 pixel wide and L pixels long were placed on a noise image (128 × 128 pixels) and scanned in the MR image domain. We obtained the 1D NPS using the slit method (1D NPS_Slit) and the 2D NPS of the noise region scanned by the slit (2D NPS_Slit). We also obtained 1D NPS using the radial frequency method (1D NPS_Radial) by averaging the NPS values on the circumference of a circle centered at the origin of the original 2D NPS. The properties of the 1D NPS_Slits varied with L and the scanning direction in PROPELLER MRI. The 2D NPS_Slit shapes matched that of the original 2D NPS, but were compressed by L/128. The central line profiles of the 2D NPS_Slits and the 1D NPS_Slits matched exactly. Therefore, the 1D NPS_Slits reflected not only the NPS values on the central axis of the original 2D NPS, but also the NPS values around the central axis. Moreover, the measurement precisions of the 1D NPS_Slits were lower than those of the 1D NPS_Radial. Consequently, it is necessary to select the approach applied for 1D NPS measurements according to the data acquisition method and the purpose of the noise evaluation.
40 CFR 122.29 - New sources and new dischargers.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 21 2010-07-01 2010-07-01 false New sources and new dischargers. 122... Application and Special NPDES Program Requirements § 122.29 New sources and new dischargers. (a) Definitions. (1) New source and new discharger are defined in § 122.2. [See Note 2.] (2) Source means any building...
Near-field thermal radiation of deep- subwavelength slits in the near infrared range.
Guo, Yan; Li, Kuanbiao; Xu, Ying; Wei, Kaihua
2017-09-18
We numerically investigate the thermal radiation of one-dimensional deep subwavelength slits in the near infrared range. Using numerical calculations of single-slit and multi-slit structures, we find that high-level radiation efficiency can be achieved for a wide spectrum when ultra-thin intermediate layers are used, and it is less affected by structure parameters. The underlying mechanisms involve Surface Plasmon Polaritons resonance and Fabry-Perot interference at each slit and the interaction between adjacent slits. This structure helps understand and improve the design of thermal radiation control devices.
Slit2 promotes tumor growth and invasion in chemically induced skin carcinogenesis.
Qi, Cuiling; Lan, Haimei; Ye, Jie; Li, Weidong; Wei, Ping; Yang, Yang; Guo, Simei; Lan, Tian; Li, Jiangchao; Zhang, Qianqian; He, Xiaodong; Wang, Lijing
2014-07-01
Slit, a neuronal guidance cue, binds to Roundabout (Robo) receptors to modulate neuronal, leukocytic, and endothelial migration. Slit has been reported to have an important effect on tumor growth and metastasis. In the current study, we evaluated the role of Slit2 in skin tumor growth and invasion in mice using a two-step chemical carcinogenesis protocol. We found that Slit2 expression correlated with the loss of basement membrane in the samples of human skin squamous cell carcinoma at different stages of disease progression. Slit2-Tg mice developed significantly more skin tumors than wild-type mice. Furthermore, the skin tumors that occurred in Slit2-Tg mice were significantly larger than those in the wild-type mice 10 weeks after 7,12-dimethylbenz[a]anthracene initiation until the end of the experiment. We also found that pathological development of the wild-type mice was delayed compared with that of Slit2-Tg mice. To further investigate the mechanism of increasing tumors in Slit2-Tg mice, we analyzed the expression of 5-bromo-2'-deoxyuridine (BrdU) in mouse skin lesions and found that the number of BrdU-positive cells and microvessel density in skin lesions were significantly higher in Slit2-Tg mice than in wild-type mice. Histological staining of PAS and type IV collagen and the colocalization of Slit2 and type IV collagen demonstrated varying degrees of loss of the basement membrane in the skin lesions from Slit2-Tg mice that were at the stage of carcinoma in situ. However, the basement membrane was well defined in the wild-type mice. In addition, MMP2, but not MMP9, was upregulated in the skin tissue of Slit2-Tg mice. Interruption of Slit2-Robo1 signaling by the antibody R5 significantly repressed the invasive capability of the squamous cell carcinoma cell line A431. Taken together, our findings reveal that Slit2 promotes DMBA/TPA-induced skin tumorigenesis by increasing cell proliferation, microvessel density, and invasive behavior of cutaneous squamous cell carcinoma, along with loss of basement membrane, by upregulation of MMP2 expression.
Westerman, Mary E; Tausch, Timothy J; Zhao, Lee C; Siegel, Jordan A; Starke, Nathan; Klein, Alexandra K; Morey, Allen F
2015-06-01
We present a novel technique using ventral slit with scrotal skin flaps (VSSF) for the reconstruction of adult buried penis without skin grafting. An initial ventral slit is made in the phimotic ring, and the penis is exposed. To cover the defect in the ventral shaft skin, local flaps are created by making a ventral midline scrotal incision with horizontal relaxing incisions. The scrotal flaps are rotated to resurface the ventral shaft. Clinical data analyzed included preoperative diagnoses, length of stay, blood loss, and operative outcomes. Complications were also recorded. Fifteen consecutive patients with a penis trapped due to lichen sclerosus (LS) or phimosis underwent repair with VSSF. Each was treated in the outpatient setting with no perioperative complications. Mean age was 51 years (range, 26-75 years), and mean body mass index was 42.6 kg/m(2) (range, 29.8-53.9 kg/m(2)). The majority of patients (13 of 15, 87%) had a pathologic diagnosis of LS. Mean estimated blood loss was 57 cc (range, 25-200 cc), mean operative time was 83 minutes (range, 35-145 minutes), and all patients were discharged on the day of surgery. The majority of patients (11 of 15, 73.3%) remain satisfied with their results and have required no further intervention. Recurrences in 3 of 15 (20.0%) were due to LS, panniculus migration, and concealment by edematous groin tissue; 2 of these patients underwent subsequent successful skin grafting. VSSF is a versatile, safe, and effective reconstructive option in appropriately selected patients with buried penis, which enables reconstruction of penile shaft skin defects without requiring complex skin grafting. Copyright © 2015 Elsevier Inc. All rights reserved.
A case of unilateral phthiriasis palpebrarum infestation involving the left eye.
Ashraf, Mohammad; Waris, Abdul; Kumar, Ashwini; Akhtar, Nahid
2014-06-06
Phthiriasis palpebrarum is a rare cause of eyelid infestation. We report a case of unilateral phthiriasis palpebrarum. A 28-year-old man presented with moderate itching associated with lacrimation and irritation in the left eye. The initial evaluation of the patient revealed multiple white dots on the left upper eyelashes. Slit-lamp examination revealed multiple nits attached to the base and shaft of the cilia. There was no hyperaemia or discharge present in the conjunctiva and the cornea was clear and shiny. The right eye was perfectly normal. The patient was treated with moxifloxacin eye ointment and was completely cured in 1 week. 2014 BMJ Publishing Group Ltd.
Advanced Optimal Extraction for the Spitzer/IRS
NASA Astrophysics Data System (ADS)
Lebouteiller, V.; Bernard-Salas, J.; Sloan, G. C.; Barry, D. J.
2010-02-01
We present new advances in the spectral extraction of pointlike sources adapted to the Infrared Spectrograph (IRS) on board the Spitzer Space Telescope. For the first time, we created a supersampled point-spread function of the low-resolution modules. We describe how to use the point-spread function to perform optimal extraction of a single source and of multiple sources within the slit. We also examine the case of the optimal extraction of one or several sources with a complex background. The new algorithms are gathered in a plug-in called AdOpt which is part of the SMART data analysis software.
Schmidt, F.H.
1958-08-12
An improved ion source is described for accurately presetting the size amd location of the gas and ion efflux opening. for determining the contour of the electrical field in the vicinity of the arc, and for generally improving the operation of the calutron source. The above features are accomplished by the use of a pair of electrically conductive coplanar plates mounted on opposite sides of the ion exit passage of the source ionization chamber and electrically connected to the source block. The plates are mounted on thc block for individual movement tramsversely of the exit slit and can be secured in place by clannping means.
Emittance formula for slits and pepper-pot measurement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, M.
1996-10-01
In this note, a rigid formula for slits and pepper-pot emittance measurement is derived. The derivation is based on the one- dimensional slit measurement setup. A mathematical generalization of the slit emittance formula to the pepper-pot measurement is discussed.
Hössl, Bernhard; Böhm, Helmut J; Schaber, Clemens F; Rammerstorfer, Franz G; Barth, Friedrich G
2009-09-01
Arachnid slit sensilla respond to minute strains in the exoskeleton. After having applied finite element (FE) analysis to simplified arrays of five straight slits (Hössl et al. J Comp Physiol A 193:445-459, 2007) we now present a computational study of the effects of more subtle natural variations in geometry, number and arrangement of slits on the slit face deformations. Our simulations show that even minor variations in these parameters can substantially influence a slit's directional response. Using white-light interferometric measurements of the surface deformations of a lyriform organ, it is shown that planar FE models are capable of predicting the principal characteristics of the mechanical responses. The magnitudes of the measured and calculated slit face deformations are in good agreement. At threshold, they measure between 1.7 and 43 nm. In a lyriform organ and a closely positioned loose group of slits, the detectable range of loads increases to approximately 3.5 times the range of the lyriform organ alone. Stress concentration factors (up to ca. 29) found in the vicinity of the slits were evaluated from the models. They are mitigated due to local thickening of the exocuticle and the arrangement of the chitinous microfibers that prevents the formation of cracks under physiological loading conditions.
On the mechanical interaction between a fluid-filled fracture and the earth's surface
Pollard, D.D.; Holzhausen, G.
1979-01-01
The mechanical interaction between a fluid-filled fracture (e.g., hydraulic fracture joint, or igneous dike) and the earth's surface is analyzed using a two-dimensional elastic solution for a slit of arbitrary inclination buried beneath a horizontal free surface and subjected to an arbitrary pressure distribution. The solution is obtained by iteratively superimposing two fundamental sets of analytical solutions. For uniform internal pressure the slit behaves essentially as if it were in an infinite region if the depth-to-center is three times greater than the half-length. For shallower slits interaction with the free surface is pronounced: stresses and displacements near the slit differ by more than 10% from values for the deeply buried slit. The following changes are noted as the depth-to-center decreases: 1. (1) the mode I stress intensity factor increases for both ends of the slit, but more rapidly at the upper end; 2. (2) the mode II stress-intensity factor is significantly different from zero (except for vertical slits) suggesting propagation out of the original plane of the slit; 3. (3) displacements of the slit wall are asymmetric such that the slit gaps open more widely near the upper end. Similar changes are noted if fluid density creates a linear pressure gradient that is smaller than the lithostatic gradient. Under such conditions natural fractures should propagate preferentially upward toward the earth's surface requiring less pressure as they grow in length. If deformation near the surface is of interest, the model should account explicitly for the free surface. Stresses and displacements at the free surface are not approximated very well by values calculated along a line in an infinite region, even when the slit is far from the line. As depth-to-center of a shallow pressurized slit decreases, the following changes are noted: 1. (1) displacements of the free surface increase to the same order of magnitude as the displacements of the slit walls, 2. (2) tensile stresses of magnitude greater than the pressure in the slit are concentrated along the free surface. The relative surface displacements over a shallow vertical slit are downward over the slit and upward to both sides of this area. The tensile stress acting parallel to the free surface over a shallow vertical slit is concentrated in two maxima adjacent to a point of very low stress immediately over the slit. The solution is used to estimate the length-to-depth ratio at which igneous sills have gained sufficient leverage on overlying strata to bend these strata upward and form a laccolith. The pronounced mode II stress intensity associated with shallow horizontal slits explains the tendency for some sills to climb to higher stratigraphie horizons as they grow in length. The bimodal tensile stress concentration over shallow vertical slits correlates qualitatively with the distribution of cracks and normal faults which flank fissure eruptions on volcanoes. The solution may be used to analyze surface displacements and tilts over massive hydraulic fractures in oil fields and to understand the behavior of hydraulic fractures in granite quarries. ?? 1979.
Kinematics of the Diffuse Ionized Gas Disk of Andromeda
NASA Astrophysics Data System (ADS)
Thelen, Alexander; Howley, K.; Guhathakurta, P.; Dorman, C.; SPLASH Collaboration
2012-01-01
This research focuses on the flattened rotating diffuse ionized gas (DIG) disk of the Andromeda Galaxy (M31). For this we use spectra from 25 multislit masks obtained by the SPLASH collaboration using the DEIMOS spectrograph on the Keck-II 10-meter telescope. Each mask contains 200 slits covering the region around M32 (S of the center of M31), the major axis of M31, and the SE minor axis. DIG emission was serendipitously detected in the background sky of these slits. By creating a normalized "sky spectrum” to remove various other sources of emission (such as night sky lines) in the background of these slits, we have examined the rotation of the DIG disk using individual line-of-sight velocity measurements of Hα, [NII] and [SII] emission. his emission is probably the result of newly formed stars ionizing the gas in the disk. The measured IG rotation will be compared to the rotation of M31's stellar disk and HI gas disk, as well as models of an infinitely thin rotating disk, to better understand the relationship between the components of the galactic disk and its differential rotation. We wish to acknowledge the NSF for funding on this project.
VizieR Online Data Catalog: WINERED CN-red band emission in comet C/2013 R1 (Shinnaka+, 2017)
NASA Astrophysics Data System (ADS)
Shinnaka, Y.; Kawakita, H.; Kondo, S.; Ikeda, Y.; Kobayashi, N.; Hamano, S.; Sameshima, H.; Fukue, K.; Matsunaga, N.; Yasui, C.; Izumi, N.; Mizumoto, M.; Otsubo, S.; Takenaka, K.; Watase, A.; Kawanishi, T.; Nakanishi, K.; Nakaoka, T.
2018-05-01
High-resolution spectroscopic observations of comet C/2013 R1 (Lovejoy; hereafter, comet Lovejoy) in the near-infrared wavelength region were performed using the WINERED spectrograph (Ikeda et al. 2016SPIE.9908E..5ZI) mounted on the Nasmyth focus of the 1.3 m Araki telescope (F/10) at Koyama Astronomical Observatory, Japan (Yoshikawa et al. 2012SPIE.8444E..6GY). We used a slit of length 47" and width 1.5". This slit width corresponds to a spectral resolving power of R=28000 (two pixels). The observations of comet Lovejoy were performed on 2013 November 30, from 19:08 UT to 21:04 UT; the total integration time was 6000 s on source. The heliocentric and geocentric distances were 0.91 au and 0.49 au, respectively, and the relative velocities of the comet to the Sun and observer were -14.5 km/s and 25.8 km/s, respectively, at the observations. We put the comet at the center of the slit during the exposures. Other calibration data (darks, flats, and comparison-lamp frames) were also acquired. (1 data file).
Diagnostic experiments at a 3 MeV test stand at Rutherford Appleton Laboratory (United Kingdom).
Gabor, C; Faircloth, D C; Lee, D A; Lawrie, S R; Letchford, A P; Pozimski, J K
2010-02-01
A front end is currently under construction consisting of a H(-) Penning ion source (65 keV, 60 mA), low energy beam transport (LEBT), and radio frequency quadrupole (3 MeV output energy) with a medium energy beam transport suitable for high power proton applications. Diagnostics can be divided either in destructive techniques such as beam profile monitor, pepperpot, slit-slit emittance scanner (preferably used during commissioning) or nondestructive, permanently installed devices such as photodetachment-based techniques. Another way to determine beam distributions is a scintillator with charge-coupled device camera. First experiments have been performed to control the beam injection into the LEBT. The influence of beam parameters such as particle energy and space-charge compensation on the two-dimensional distribution and profiles will be presented.
SpcAudace: Spectroscopic processing and analysis package of Audela software
NASA Astrophysics Data System (ADS)
Mauclaire, Benjamin
2017-11-01
SpcAudace processes long slit spectra with automated pipelines and performs astrophysical analysis of the latter data. These powerful pipelines do all the required steps in one pass: standard preprocessing, masking of bad pixels, geometric corrections, registration, optimized spectrum extraction, wavelength calibration and instrumental response computation and correction. Both high and low resolution long slit spectra are managed for stellar and non-stellar targets. Many types of publication-quality figures can be easily produced: pdf and png plots or annotated time series plots. Astrophysical quantities can be derived from individual or large amount of spectra with advanced functions: from line profile characteristics to equivalent width and periodogram. More than 300 documented functions are available and can be used into TCL scripts for automation. SpcAudace is based on Audela open source software.
Star scanner. [with a reticle with a pair of slits having differing separation
NASA Technical Reports Server (NTRS)
Gutshall, R. L.; Mcconaughey, R. T.; Volpe, F. A. (Inventor)
1974-01-01
A star scanner on a spin stabilized spacecraft is described which includes a reticle with a pair of slits having different separations as a function of the spacecraft vertical plane, to form a V slit. The time between a star image crossing one of the slits relative to a reference telemetry time provides an indication of azimuth angle. The time between the image crossing the two slits provides an indication of elevation angle of the star. If a star cluster is detected such that two stars pass the slits in less time than normally required for a single star to cross the two slits, an indication of the cluster occurrence is derived. Means are provided to prevent effective detection of large celestial bodies, such as the sun or moon.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kimura, Shin-Ichi; Ito, Takahiro; Hosaka, Masahito
A novel variably polarized angle-resolved photoemission spectroscopy beamline in the vacuum-ultraviolet (VUV) region has been installed at the UVSOR-II 750 MeV synchrotron light source. The beamline is equipped with a 3 m long APPLE-II type undulator with horizontally/vertically linear and right/left circular polarizations, a 10 m Wadsworth type monochromator covering a photon energy range of 6-43 eV, and a 200 mm radius hemispherical photoelectron analyzer with an electron lens of a {+-}18 deg. acceptance angle. Due to the low emittance of the UVSOR-II storage ring, the light source is regarded as an entrance slit, and the undulator light is directlymore » led to a grating by two plane mirrors in the monochromator while maintaining a balance between high-energy resolution and high photon flux. The energy resolving power (h{nu}/{Delta}h{nu}) and photon flux of the monochromator are typically 1x10{sup 4} and 10{sup 12} photons/s, respectively, with a 100 {mu}m exit slit. The beamline is used for angle-resolved photoemission spectroscopy with an energy resolution of a few meV covering the UV-to-VUV energy range.« less
[Remote Slit Lamp Microscope Consultation System Based on Web].
Chen, Junfa; Zhuo, Yong; Liu, Zuguo; Chen, Yanping
2015-11-01
To realize the remote operation of the slit lamp microscope for department of ophthalmology consultation, and visual display the real-time status of remote slit lamp microscope, a remote slit lamp microscope consultation system based on B/S structure is designed and implemented. Through framing the slit lamp microscope on the website system, the realtime acquisition and transmission of remote control and image data is realized. The three dimensional model of the slit lamp microscope is established and rendered on the web by using WebGL technology. The practical application results can well show the real-time interactive of the remote consultation system.
Transmission characteristics of a subwavelength metallic slit with perpendicular groove
NASA Astrophysics Data System (ADS)
Jin, Li; Zhou, Jun; Zou, Weibo; Zhang, Haopeng; Zhang, Lingfen
2011-12-01
The transmission property of a subwavelength metallic slit with perpendicular groove is investigated by using finite element method. The lengths for the slits at both sides of the groove are set as the length of a metallic slit without groove at the surface plasmon fundamental mode resonance. In the grooved subwavelength metallic slit, enhanced transmission is found to be attributed to two kinds of resonance including surface plasmon waveguide resonance along the propagating direction and the transversely constructive interferential resonance. For the former resonance, integer antinodes of surface plasmon are formed in the groove. For the later resonance, there is a tradeoff between the maximum amplitude and the full width at half maximum of the transmitted peaks with the change of the groove width. And, the transmission enhancement of the grooved subwavelength metallic slit is related to the number of groove and the incident wavelength. Furthermore, the above resonances also exist in the structure whose lengths of metallic slits are set as the length of a slit without groove at the surface plasmon high-order mode resonance. By optimizing the geometric parameters, the transmission enhancement of the grooved subwavelength metallic slit as high as about 15367% is achieved.
Apparent Corneal Ectasia After Bilateral Intrastromal Femtosecond Laser Treatment for Presbyopia.
Dukic, Adrijana; Bohac, Maja; Pasalic, Adi; Koncarevic, Mateja; Anticic, Marija; Patel, Sudi
2016-11-01
To report a case of apparent corneal ectasia after intrastromal femtosecond laser treatment for presbyopia (INTRACOR). A healthy 56-year-old male with low hyperopia underwent an unremarkable bilateral INTRACOR procedure in March/April 2011. The patient was discharged after follow-up and returned 5 years later. Before discharge, the monocular logarithm of the minimal angle of resolution uncorrected distance visual acuity (UDVA) values were R, 0.0 and L, 0.10. In both eyes near (UNVA) visual acuities were 0.0. There were signs of slight posterior central corneal steepening without loss of corneal stability. Five years postop, monocular UDVA and UNVA values were 0.4 and 0.0, respectively. Ectasia was observed in both eyes, and the centrally placed 5 concentric rings after the INTRACOR procedure were visible under slit-lamp biomicroscopy. There is no clear reason to explain why the patient developed bilateral corneal steepening. It could be that the patient's corneal stromal fibers gradually weakened over this 5-year period.
NASA Astrophysics Data System (ADS)
Qi, Yunping; Zhang, Xuewei; Hu, Yue; Nan, Xianghong; Wang, Xiangxian
2017-10-01
The non-resonantly enhanced optical transmission phenomenon of sub-wavelength metallic slits on a thin film is significant for broadband light integrated devices. In order to improve the EOT characteristics of sub-wavelength metallic slits further more, in this paper, wedge-shape metallic slits array embedded with rectangular cavities structure is proposed and its transmission properties are investigated using the finite element method. The results show that wedgeshape metallic slits array can achieve higher transmission compared with straight slits array embedded with rectangular cavities and the light is strongly localized and enhanced at the slit exits. We describe the phenomenon with a transmission line model. The width of entrance of the slit influences the transmission property: the transmittance can be 94%, after optimizing the structure parameters, with the widths 150nm and 30nm at the entrance and exit of the slit, respectively. The thickness of metal film influences the transmission peak position and transmission rate: when the increase of the thickness of the metal film, the transmittance increases and the transmission peak is red-shift, however, the law of long wavelength range is opposite. In addition, the effects of structural period of wedge-shaped slits embedded with rectangular cavities structure on the transmission property are also studied. These results would be helpful for optical signal transmission and the design of near field optical conductor devices with higher transmission capability.
Liu, Junhui; Hou, Weiping; Guan, Tao; Tang, Luyao; Zhu, Xufei; Li, Yi; Hou, Shihui; Zhang, Jun; Chen, Hua; Huang, Yunjian
2018-05-01
Abnormal angiogenesis plays a pathological role in diabetic nephropathy (DN), contributing to glomerular hypertrophy and microalbuminuria. Slit2/Robo1 signaling participates in angiogenesis in some pathological contexts, but whether it is involved in glomerular abnormal angiogenesis of early DN is unclear. The present study evaluated the effects of Slit2/Robo1 signaling pathway on angiogenesis of human renal glomerular endothelial cells (HRGECs) exposed to a diabetic-like environment or recombinant Slit2-N. To remove the effect of Slit2 derived from mesangial cells, human renal mesangial cells (HRMCs) grown in high glucose (HG) medium (33 mM) were transfected with Slit2 siRNA and then the HG-HRMCs-CM with Slit2 depletion was collected after 48 h. HRGECs were cultured in the HG-HRMCs-CM or recombinant Slit2-N for 0, 6, 12, 24, or 48 h. The mRNA and protein expressions of Slit2/Robo1, PI3K/Akt and HIF-1α/VEGF signaling pathways were detected by quantitative real-time PCR, western blotting, and ELISA, respectively. The CCK-8 cell proliferation assay, flow cytometry and the scratch wound-healing assay were used to assess cell proliferation, cycles, and migration, respectively. Matrigel was used to perform a tubule formation assay. Our results showed that the HG-HRMCs-CM with Slit2 depletion enhanced the activation of Slit2/Robo1, PI3K/Akt, and HIF-1α/VEGF signaling in HRGECs in time-dependent manner (0-24 h post-treatment). In addition, the HG-HRMCs-CM with Slit2 depletion significantly promoted HRGECs proliferation, migration, and tube formation. Pretreatment of HRGECs with Robo1 siRNA suppressed the activation of PI3K/Akt and HIF-1α/VEGF signaling and inhibited angiogenesis, whereas PI3K inhibitor suppressed HIF-1α/VEGF signaling, without influencing Robo1 expression. In the HRGECs treated with Slit2-N, Slit2-N time-dependently enhanced the activation of Robo1/PI3K/Akt/VEGF pathway but not HIF-1α activity, and promoted HRGECs proliferation, migration, and tube formation. The effects induced by Slit2 were also abolished by Robo1 siRNA and PI3K inhibitor. Taken together, our findings indicate that in a diabetic-like environment, in addition to mesangial cells, autocrine activation of Slit2/Robo1 signaling of HRGECs may contribute to angiogenesis of HRGECs through PI3K/Akt/VEGF pathway; therefore, Slit2/Robo1 signaling may be a potent therapeutic target for the treatment of abnormal angiogenesis in early DN and may have broad implications for the treatment of other diseases dependent on pathologic angiogenesis.
Radiographic screen-film noise power spectrum: variation with microdensitometer slit length.
Sandrik, J M; Wagner, R F
1981-08-15
When the noise power spectrum (NPS) of a radiographic screen-film system is measured by microdensito-metrically scanning the film with a long narrow slit, sufficient slit length allows estimation of a section of the 2-D NPS from the 1-D film scans; insufficient length causes underestimation of the NPS, particularly at low frequencies ( greater, similar1 cycle/mm). Spectra of Hi-Plus, Par Speed, and Detail screens used with XRP films measured as a function of microdensitometer slit length tended to plateau at long slit lengths. The slit length was considered sufficient when NPS components at 0.4 cycle/mm were within 5% of the plateau. This occurred for slit lengths of at least 4.2, 2.6, and 2.5 mm for Hi-Plus, Par Speed, and Detail systems, respectively.
NASA Astrophysics Data System (ADS)
Maeno, Tsuyoshi; Sakurai, Yukihiko; Unou, Takanori; Ichikawa, Kouji; Fujiwara, Osamu
It is well-known that electromagnetic (EM) disturbances in vehicle-mounted radios are mainly caused by conducted noise currents flowing through wiring-harnesses from vehicle-mounted printed circuit boards (PCBs) with common ground patterns with slits. To evaluate the noise current outflows from the PCBs of this kind, we previously measured noise current outflows from four types of simple three-layer PCBs having two perpendicular signal traces and different ground patterns with/without slits, and showed that slits on a ground pattern allow conducted noise currents to flow out from PCBs, while the levels for the symmetric slits ground type are smaller compared to the case for two asymmetric slits ground types. In the present study, to further investigate the above finding, we fabricated six types of simple two-layer PCBs having two parallel signal traces and different ground patterns with/without slits, and measured the cross-talk noise between the traces. As a result, we found that the ground patterns with the slits perpendicular to the traces increase the cross-talk noise levels, which are larger by 19-42 dB than those for the ground pattern with no slits, while the ground patterns with the slits in parallel with the traces can suppress the noise levels, which are slightly smaller by 2.5-4.5 dB compared to the case for the no-slit ground pattern. These results were confirmed by the FDTD simulation, and were also qualitatively explained from an equivalent bridge circuit model we previously proposed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mueller, M.M.
1979-11-01
A simple method for reconstructing spherically symmetric objects from slit-imaged emission was recently described by Vest and Steel. Although this method is valid for infinitesimal slit widths and practically noise-free irradiance data, it is shown here that its validity does not extend to slits of practical width in the laser-fusion program. However, a method is given for reducing the Vest--Steel plots with practical apertures to obtain information on core diameter, shell diameter, and shell thickness.
Precision optical slit for high heat load or ultra high vacuum
Andresen, N.C.; DiGennaro, R.S.; Swain, T.L.
1995-01-24
This invention relates generally to slits used in optics that must be precisely aligned and adjusted. The optical slits of the present invention are useful in x-ray optics, x-ray beam lines, optical systems in which the entrance slit is critical for high wavelength resolution. The invention is particularly useful in ultra high vacuum systems where lubricants are difficult to use and designs which avoid the movement of metal parts against one another are important, such as monochromators for high wavelength resolution with ultra high vacuum systems. The invention further relates to optical systems in which temperature characteristics of the slit materials is important. The present invention yet additionally relates to precision slits wherein the opposing edges of the slit must be precisely moved relative to a center line between the edges with each edge retaining its parallel orientation with respect to the other edge and/or the center line. 21 figures.
Precision optical slit for high heat load or ultra high vacuum
Andresen, Nord C.; DiGennaro, Richard S.; Swain, Thomas L.
1995-01-01
This invention relates generally to slits used in optics that must be precisely aligned and adjusted. The optical slits of the present invention are useful in x-ray optics, x-ray beam lines, optical systems in which the entrance slit is critical for high wavelength resolution. The invention is particularly useful in ultra high vacuum systems where lubricants are difficult to use and designs which avoid the movement of metal parts against one another are important, such as monochrometers for high wavelength resolution with ultra high vacuum systems. The invention further relates to optical systems in which temperature characteristics of the slit materials is important. The present invention yet additionally relates to precision slits wherein the opposing edges of the slit must be precisely moved relative to a center line between the edges with each edge retaining its parallel orientation with respect to the other edge and/or the center line.
Measuring Slit Width and Separation in a Diffraction Experiment
ERIC Educational Resources Information Center
Gan, K. K.; Law, A. T.
2009-01-01
We present a procedure for measuring slit width and separation in single- and double-slit diffraction experiments. Intensity spectra of diffracted laser light are measured with an optical sensor (PIN diode). Slit widths and separations are extracted by fitting to the measured spectra. We present a simple fitting procedure to account for the…
Time-resolved double-slit interference pattern measurement with entangled photons
Kolenderski, Piotr; Scarcella, Carmelo; Johnsen, Kelsey D.; Hamel, Deny R.; Holloway, Catherine; Shalm, Lynden K.; Tisa, Simone; Tosi, Alberto; Resch, Kevin J.; Jennewein, Thomas
2014-01-01
The double-slit experiment strikingly demonstrates the wave-particle duality of quantum objects. In this famous experiment, particles pass one-by-one through a pair of slits and are detected on a distant screen. A distinct wave-like pattern emerges after many discrete particle impacts as if each particle is passing through both slits and interfering with itself. Here we present a temporally- and spatially-resolved measurement of the double-slit interference pattern using single photons. We send single photons through a birefringent double-slit apparatus and use a linear array of single-photon detectors to observe the developing interference pattern. The analysis of the buildup allows us to compare quantum mechanics and the corpuscular model, which aims to explain the mystery of single-particle interference. Finally, we send one photon from an entangled pair through our double-slit setup and show the dependence of the resulting interference pattern on the twin photon's measured state. Our results provide new insight into the dynamics of the buildup process in the double-slit experiment, and can be used as a valuable resource in quantum information applications. PMID:24770360
Harada, Ken; Akashi, Tetsuya; Niitsu, Kodai; Shimada, Keiko; Ono, Yoshimasa A; Shindo, Daisuke; Shinada, Hiroyuki; Mori, Shigeo
2018-01-17
Advanced electron microscopy technologies have made it possible to perform precise double-slit interference experiments. We used a 1.2-MV field emission electron microscope providing coherent electron waves and a direct detection camera system enabling single-electron detections at a sub-second exposure time. We developed a method to perform the interference experiment by using an asymmetric double-slit fabricated by a focused ion beam instrument and by operating the microscope under a "pre-Fraunhofer" condition, different from the Fraunhofer condition of conventional double-slit experiments. Here, pre-Fraunhofer condition means that each single-slit observation was performed under the Fraunhofer condition, while the double-slit observations were performed under the Fresnel condition. The interference experiments with each single slit and with the asymmetric double slit were carried out under two different electron dose conditions: high-dose for calculation of electron probability distribution and low-dose for each single electron distribution. Finally, we exemplified the distribution of single electrons by color-coding according to the above three types of experiments as a composite image.
The extent of slits at the interfaces between luting cements and enamel, dentin and alloy.
Oilo, G
1978-01-01
Four different cements were used to assess the presence of slits at the cement/tooth or the cement/alloy interfaces using a tooth-crown model. The model consisted of ground sections of teeth and plane plates of silver/palladium alloy. The plates were fixed with bolts between two brass plates and with three different dimensions of the cement film between tooth and alloy, i.e. 50 micrometer, 100 micrometer and 200 micrometer. The tooth-alloy specimens were sectioned and the adaption of cements was studied with an indirect technique (replica) in a scanning electron microscope. The extent of slits was expressed as the length of all slits relative to the total length of the interface in each specimen. The results showed that the zinc phosphate cement and polycarboxylate cement exhibited a slight to moderate tendency to formation of slits at the interfaces. The EBA cement had a small extent of slits adjacent to thin cement films, but more slits were observed with increasing film thickness. The composite resin cement had a marked tendency to slit formation independent of the cement film thickness.
Progesterone down-regulates SLIT/ROBO expression in mouse corpus luteum.
Zhang, Xuejing; Mi, Meiyan; Hao, Weili; Fan, Qiongying; Gao, Bulang
2017-09-01
Progesterone produced by the corpus luteum (CL) is essential for preparation, implantation and maintenance of gestation. Furthermore, progesterone plays a protective role against luteolysis in rodents. It has been reported that Slit/Robo family members expressed in the CL and involved in prostaglandin F 2α (PGF 2α ) induced luteolysis. However, the interactions between progesterone and Slits/Robos in CL are not clear. This study was designed to examine whether or not luteolysis is regulated by the interaction of progesterone and Slits/Robos in mouse CL. In the current study, we used Real-time PCR to identify the effect of progesterone on Slit2/Robo1 expression in cultured luteal cells in vitro, and the exogenous progesterone injection on mouse luteolysis and Slit/Robo expression in vivo was studied via Real-time PCR and Western bolt. Our in vitro experiment revealed that 1μM progesterone significantly decreased Slit2/Robo1 mRNA levels at 6h, 12h and 24h. Our in vivo experiment showed that the mRNA and protein levels of Slit2 and Robo1 decreased significantly 7days after progesterone supplement. These findings indicate that progesterone maintains CL function and resists luteolysis possibly through down-regulating Slit/Robo signaling pathway in the CL. Copyright © 2017 Elsevier GmbH. All rights reserved.
The SLIT/ROBO pathway: a regulator of cell function with implications for the reproductive system
Dickinson, Rachel E; Duncan, W Colin
2010-01-01
The secreted SLIT glycoproteins and their Roundabout (ROBO) receptors were originally identified as important axon guidance molecules. They function as a repulsive cue with an evolutionarily conserved role in preventing axons from migrating to inappropriate locations during the assembly of the nervous system. In addition the SLIT-ROBO interaction is involved in the regulation of cell migration, cell death and angiogenesis and, as such, has a pivotal role during the development of other tissues such as the lung, kidney, liver and breast. The cellular functions that the SLIT/ROBO pathway controls during tissue morphogenesis are processes that are dysregulated during cancer development. Therefore inactivation of certain SLITs and ROBOs is associated with advanced tumour formation and progression in disparate tissues. Recent research has indicated that the SLIT/ROBO pathway could also have important functions in the reproductive system. The fetal ovary expresses most members of the SLIT and ROBO families. The SLITs and ROBOs also appear to be regulated by steroid hormones and regulate physiological cell functions in adult reproductive tissues such as the ovary and endometrium. Furthermore several SLITs and ROBOs are aberrantly expressed during the development of ovarian, endometrial, cervical and prostate cancer. This review will examine the roles this pathway could have in the development, physiology and pathology of the reproductive system and highlight areas for future research that could further dissect the influence of the SLIT/ROBO pathway in reproduction. PMID:20100881
The SLIT-ROBO pathway: a regulator of cell function with implications for the reproductive system.
Dickinson, Rachel E; Duncan, W Colin
2010-04-01
The secreted SLIT glycoproteins and their Roundabout (ROBO) receptors were originally identified as important axon guidance molecules. They function as a repulsive cue with an evolutionarily conserved role in preventing axons from migrating to inappropriate locations during the assembly of the nervous system. In addition the SLIT-ROBO interaction is involved in the regulation of cell migration, cell death and angiogenesis and, as such, has a pivotal role during the development of other tissues such as the lung, kidney, liver and breast. The cellular functions that the SLIT/ROBO pathway controls during tissue morphogenesis are processes that are dysregulated during cancer development. Therefore inactivation of certain SLITs and ROBOs is associated with advanced tumour formation and progression in disparate tissues. Recent research has indicated that the SLIT/ROBO pathway could also have important functions in the reproductive system. The fetal ovary expresses most members of the SLIT and ROBO families. The SLITs and ROBOs also appear to be regulated by steroid hormones and regulate physiological cell functions in adult reproductive tissues such as the ovary and endometrium. Furthermore several SLITs and ROBOs are aberrantly expressed during the development of ovarian, endometrial, cervical and prostate cancer. This review will examine the roles this pathway could have in the development, physiology and pathology of the reproductive system and highlight areas for future research that could further dissect the influence of the SLIT/ROBO pathway in reproduction.
Electron beam diagnostic for profiling high power beams
Elmer, John W [Danville, CA; Palmer, Todd A [Livermore, CA; Teruya, Alan T [Livermore, CA
2008-03-25
A system for characterizing high power electron beams at power levels of 10 kW and above is described. This system is comprised of a slit disk assembly having a multitude of radial slits, a conducting disk with the same number of radial slits located below the slit disk assembly, a Faraday cup assembly located below the conducting disk, and a start-stop target located proximate the slit disk assembly. In order to keep the system from over-heating during use, a heat sink is placed in close proximity to the components discussed above, and an active cooling system, using water, for example, can be integrated into the heat sink. During use, the high power beam is initially directed onto a start-stop target and after reaching its full power is translated around the slit disk assembly, wherein the beam enters the radial slits and the conducting disk radial slits and is detected at the Faraday cup assembly. A trigger probe assembly can also be integrated into the system in order to aid in the determination of the proper orientation of the beam during reconstruction. After passing over each of the slits, the beam is then rapidly translated back to the start-stop target to minimize the amount of time that the high power beam comes in contact with the slit disk assembly. The data obtained by the system is then transferred into a computer system, where a computer tomography algorithm is used to reconstruct the power density distribution of the beam.
Ultra-sensing with slit-enhanced infrared spectroscopy (Conference Presentation)
NASA Astrophysics Data System (ADS)
Mayerhöfer, Thomas G.; Knipper, Richard; Hübner, Uwe; Cialla-May, Dana; Weber, Karina; Popp, Jürgen
2017-02-01
Infrared spectroscopy enables the label-free detection of structure specific fingerprints of analytes. The sensitivity of corresponding methods can strongly be enhanced by attaching analytes on plasmonic active surfaces. We introduce a slit array metamaterial perfect absorber (SAMPA) [1] consisting of a dielectric layer sandwiched between two Au layers of which the upper layer is perforated with a periodic array of slits. This structure combines the principle of Extraordinary Optical Transmission (more light is transmitted through a hole than is incident on its surface) with that of Perfect Absorption (reflectance and transmittance are virtually zero). Accordingly, within the slights the electric fields are strongly enhanced and light-matter interaction is correspondingly greatly amplified. Thus, already small concentrations of analytes down to a monolayer can be detected and identified by their spectral fingerprints with a standard mid-infrared spectrometer. Closely related to the SAMPAs are plasmonic slit absorbers, which simply consist of slit arrays in thin gold layers deposited on a layer of Si3N4.[2] These slit arrays operate like unstructured gold layers if the incident light is polarized parallel to the long slit axes. In contrast, for light polarized perpendicular to the long slit axis, the plasmon is excited. By the introduction of a second slit, which is rotated relative to the first slit, both principal polarization states excite plasmon resonances which can be made to differ in wavelength. As a consequence, the operating wavelength range of this slit array can be tuned by adjusting the polarization state of the incoming light. [1] Mayerhöfer, T.G., et al.. ACS Photonics, 2015. 2(11): p. 1567-1575. [2] Knipper, R., et. al., in preparation.
2009-02-01
All Sky Survey ( 2MASS ) coordinates of the nucleus were used to verify the coordinates of each observation. The SH and LH staring observations include...isolate the nuclear region in the mapping obser- vations, fluxes were extracted from a single slit coinciding with the radio or 2MASS nuclear...presence of a hard X-ray point source coin- cident with either the radio or 2MASS nucleus and log(LX) 38 erg s−1. The resulting subsample consists of
Deformed ellipsoidal diffraction grating blank
NASA Technical Reports Server (NTRS)
Decew, Alan E., Jr.
1994-01-01
The Deformed Ellipsoidal Grating Blank (DEGB) is the primary component in an ultraviolet spectrometer. Since one of the major concerns for these instruments is throughput, significant efforts are made to reduce the number of components and subsequently reflections. Each reflection results in losses through absorption and scattering. It is these two sources of photon loss that dictated the requirements for the DEGB. The first goal is to shape the DEGB in such a way that the energy at the entrance slit is focused as well as possible on the exit slit. The second goal is to produce a surface smooth enough to minimize the photon loss due to scattering. The program was accomplished in three phases. The first phase was the fabrication planning. The second phase was the actual fabrication and initial testing. The last phase was the final testing of the completed DEGB.
STIS Target Acquisitions During SMOV
NASA Astrophysics Data System (ADS)
Katsanis, Rocio M.; Downes, Ron; Hartig, George; Kraemer, Steve
1997-07-01
We summarize the first results on the analysis of in-flight STIS target acquisition (ACQ and ACQ/PEAK). These results show that the STIS target acquisition (ACQ) is working very accurately for point sources (within 0.5 pixels = 0.025 arcseconds), about 4 times better than specified in the Instrument Handbook. As a result of the accuracy of the ACQ algorithm, we are no longer recommending to perform ACQ/PEAKs for the 0.2 arcsecond wide slits. For diffuse acquisitions the accuracy varies with target size. Although analysis of ACQ/PEAK data is hampered by a flight software problem, we anticipate that peakups will be accurate to roughly ±5% of the slit width (instead of the ±15% pr eviously advertised). We are implementing several enhancements to the flight software that will take effect by mid- August to improve the quality of the acquisitions.
Bravo-Abad, J; Martín-Moreno, L; García-Vidal, F J
2004-02-01
In this work we explore the transmission properties of a single slit in a metallic screen. We analyze the dependence of these properties on both slit width and angle of incident radiation. We study in detail the crossover between the subwavelength regime and the geometrical-optics limit. In the subwavelength regime, resonant transmission linked to the excitation of waveguide resonances is analyzed. Linewidth of these resonances and their associated electric-field intensities are controlled by just the width of the slit. More complex transmission spectra appear when the wavelength of light is comparable to the slit width. Rapid oscillations associated with the emergence of different propagating modes inside the slit are the main features appearing in this regime.
Structure and properties of optical-discharge plasma in CO2-laser beam near target surface
NASA Astrophysics Data System (ADS)
Danshchikov, Ye. V.; Dymshakov, V. A.; Lebedev, F. V.; Ryazanov, A. V.
1986-05-01
An experimental study of optical-discharge plasma in a CO2-laser beam at a target surface was made for the purpose of exploring the not yet understood role of this plasma in the laser-target interaction process. Such a plasma was produced by means of a quasi-continuous CO2-laser with an unstable resonator, its power being maintained constant for 1 ms periods. Its radiation was focused on the surfaces of thick and seeding thin Al, Ti, and Ta targets inclined at an approximately 70 deg. angle to the beam, inside a hermetic chamber containing air, argon, or helium under atmospheric pressure. The radiation intensity distribution over the focal plane and the nearest caustic surface in the laser beam was measured along with the plasma parameters, the latter by the methods of spectral analysis and photoelectric recording. The instrumentation for this purpose included an MDR-3 monochromator with an entrance slit, a double electron-optical converter, a memory oscillograph, and an SI-10-30 ribbon lamp as radiation reference standard. The results yielded integral diametral intensity distributions of the emission lines Ti-II (457.2 nm), Ti-I (464 nm), Ar-II (462 nm), radial and axial temperature profiles of optical discharge in metal vapor in surrounding gas, and the radial temperature profile of irradiated metal surface at successive instants of time. The results reveal marked differences between the structures and the properties of optical-discharge plasma in metal vapor and in surrounding gas, optical discharge in the former being characterized by localization within the laser beam and optical discharge in the latter being characterized by a drift away from the target.
High sensitivity pulse-counting mass spectrometer system for noble gas analysis
NASA Technical Reports Server (NTRS)
Hohenberg, C. M.
1980-01-01
A pulse-counting mass spectrometer is described which is comprised of a new ion source of cylindrical geometry, with exceptional optical properties (the Baur source), a dual focal plane externally adjustable collector slits, and a 17-stage Allen-type electron multiplier, all housed in a metal 21 cm radius, 90 deg magnetic sector flight tube. Mass discrimination of the instrument is less than 1 per mil per mass unit; the optical transmission is more than 90%; the source sensitivity (Faraday collection) is 4 ma/torr at 250 micron emission; and the abundance sensitivity is 30,000.
Ultrathin multi-slit metamaterial as excellent sound absorber: Influence of micro-structure
NASA Astrophysics Data System (ADS)
Ren, S. W.; Meng, H.; Xin, F. X.; Lu, T. J.
2016-01-01
An ultrathin (subwavelength) hierarchy multi-slit metamaterial with simultaneous negative effective density and negative compressibility is proposed to absorb sound over a wide frequency range. Different from conventional acoustic metamaterials having only negative real parts of acoustic parameters, the imaginary parts of effective density and compressibility are both negative for the proposed metamaterial, which result in superior viscous and thermal dissipation of sound energy. By combining the slit theory of sound absorption with the double porosity theory for porous media, a theoretical model is developed to investigate the sound absorption performance of the metamaterial. To verify the model, a finite element model is established to calculate the effective density, compressibility, and sound absorption of the metamaterial. It is theoretically and numerically confirmed that, upon introducing micro-slits into the meso-slits matrix, the multi-slit metamaterial possesses indeed negative imaginary parts of effective density and compressibility. The influence of micro-slits on the acoustical performance of the metamaterial is analyzed in the context of its specific surface area and static flow resistivity. This work shows great potential of multi-slit metamaterials in noise control applications that require both small volume and small weight of sound-absorbing materials.
Shape distortions and Gestalt grouping in anorthoscopic perception
Aydın, Murat; Herzog, Michael H.; Öğmen, Haluk
2011-01-01
When a figure moves behind a stationary narrow slit, observers often report seeing the figure as a whole, a phenomenon called slit viewing or anorthoscopic perception. Interestingly, in slit viewing, the figure is perceived compressed along the axis of motion. As with other perceptual distortions, it is unclear whether the perceptual space in the vicinity of the slit or the representation of the figure itself undergoes compression. In a psychophysical experiment, we tested these two hypotheses. We found that the percept of a stationary bar, presented within the slit, was not distorted even when at the same time a circle underwent compression by moving through the slit. This result suggests that the compression of form results from figural rather than from space compression. In support of this hypothesis, we found that when the bar was perceptually grouped with the circle, the bar appeared compressed. Our results show that, in slit viewing, the distortion occurs at a non-retinotopic level where grouped objects are jointly represented. PMID:19757947
Zhu, Yechuan; Yuan, Weizheng; Li, Wenli; Sun, Hao; Qi, Kunlun; Yu, Yiting
2018-01-15
Slit arrays based on noble metals have been widely proposed as planar transverse-magnetic (TM)-lenses, illuminated by a linearly polarized light with the polarization perpendicular to slits and implementing the focusing capability beyond the diffraction limit. However, due to intrinsic plasmonic losses, these TM-lenses cannot work efficiently in the ultraviolet wavelengths. In this Letter, taking advantage of the unique transmission through metallic slits not involving plasmonic losses, a metallic slit array with transverse-electric (TE)-polarized design is proposed, showing for the first time, to the best of our knowledge, the realization of sub-diffraction-limit focusing for ultraviolet light. Additionally, in contrast to the situations of TM-lenses, a wider slit leads to a greater phase delay and much larger slits can be arranged to construct the TE-lenses, which is quite beneficial for practical fabrication. Furthermore, deep-subwavelength focusing can be achieved by utilizing the immersing technology.
NASA Astrophysics Data System (ADS)
Shabani, H.; Doblas, A.; Saavedra, G.; Preza, C.
2018-02-01
Three-dimensional (3D) structured illumination (SI) patterns that include lateral and axial variations have attracted more attention recently as their use in fluorescence microscope enhances the 3D resolution of the native imaging system. 3D SI patterns have already been created by interfering three mutually-coherent waves using a diffraction grating or some electro-optical devices such as spatial light modulators. Here, an interesting approach to generate a 3D SI pattern of tunable modulation frequency is shown. Our proposed illumination system is based on the incoherent illumination of a Fresnel biprism using several equidistant linear sources (i.e., slits). Previously, we investigated and compared numerically this tunable SI microscopy (SIM) system with the one achieved with three-wave interference. In this contribution, we implement our proposed incoherent 3D SIM system of tunable-frequency in an open-setup. We evaluate the axial confinement of the illumination pattern obtained with this system by recording the SI pattern using a mirror sample and different number of slits and compare these data with simulation results. Moreover, we verify that with a higher number of slits used, the axial confinement of the pattern increases, and consequently, the system's optical sectioning capability improves.
Development of integrated photonic-dicers for reformatting the point-spread-function of a telescope
NASA Astrophysics Data System (ADS)
MacLachlan, David G.; Harris, Robert; Choudhury, Debaditya; Arriola, Alexander; Brown, Graeme; Allington-Smith, Jeremy; Thomson, Robert R.
2014-07-01
Spectroscopy is a technique of paramount importance to astronomy, as it enables the chemical composition, distances and velocities of celestial objects to be determined. As the diameter of a ground-based telescope increases, the pointspread- function (PSF) becomes increasingly degraded due to atmospheric seeing. A degraded PSF requires a larger spectrograph slit-width for efficient coupling and current spectrographs for large telescopes are already on the metre scale. This presents numerous issues in terms of manufacturability, cost and stability. As proposed in 2010 by Bland-Hawthorn et al, one approach which may help to improve spectrograph stability is a guided wave transition, known as a "photonic-lantern". These devices enable the low-loss reformatting of a multimode PSF into a diffraction-limited source (in one direction). This pseudo-slit can then be used as the input to a traditional spectrograph operating at the diffraction limit. In essence, this approach may enable the use of diffractionlimited spectrographs on large telescopes without an unacceptable reduction in throughput. We have recently demonstrated that ultrafast laser inscription can be used to realize "integrated" photoniclanterns, by directly writing three-dimensional optical waveguide structures inside a glass substrate. This paper presents our work on developing ultrafast laser inscribed devices capable of reformatting a multimode telescope PSF into a diffraction-limited slit.
Characteristics and performance of a two-lens slit spatial filter for high power lasers
NASA Astrophysics Data System (ADS)
Xiong, Han; Gao, Fan; Zhang, Xiang; Zhuang, Zhenwu; Zhao, Jianjun; Yuan, Xiao
2017-05-01
The characteristics of a two-lens slit spatial filtering system on image relay and spatial filtering are discussed with detailed theoretical calculation and numerical simulation. The slit spatial filter can be used as the cavity spatial filter in large laser systems, such as National Ignition Facility, which can significantly decrease the focal intensity in cavity spatial filter and suppress or even avoid the pinhole (slit) closure while keeping the output power and beam quality. Additionally, the overall length of the cavity spatial filter can be greatly reduced with the use of the two-lens slit spatial filter.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Guang; Li, Yan; Wang, Xiao-yu
2013-05-01
Formation of the neural tube is the morphological hallmark for development of the embryonic central nervous system (CNS). Therefore, neural tube development is a crucial step in the neurulation process. Slit/Robo signaling was initially identified as a chemo-repellent that regulated axon growth cone elongation, but its role in controlling neural tube development is currently unknown. To address this issue, we investigated Slit/Robo1 signaling in the development of chick neCollege of Life Sciences Biocentre, University of Dundee, Dundee DD1 5EH, UKural tube and transgenic mice over-expressing Slit2. We disrupted Slit/Robo1 signaling by injecting R5 monoclonal antibodies into HH10 neural tubes tomore » block the Robo1 receptor. This inhibited the normal development of the ventral body curvature and caused the spinal cord to curl up into a S-shape. Next, Slit/Robo1 signaling on one half-side of the chick embryo neural tube was disturbed by electroporation in ovo. We found that the morphology of the neural tube was dramatically abnormal after we interfered with Slit/Robo1 signaling. Furthermore, we established that silencing Robo1 inhibited cell proliferation while over-expressing Robo1 enhanced cell proliferation. We also investigated the effects of altering Slit/Robo1 expression on Sonic Hedgehog (Shh) and Pax7 expression in the developing neural tube. We demonstrated that over-expressing Robo1 down-regulated Shh expression in the ventral neural tube and resulted in the production of fewer HNK-1{sup +} migrating neural crest cells (NCCs). In addition, Robo1 over-expression enhanced Pax7 expression in the dorsal neural tube and increased the number of Slug{sup +} pre-migratory NCCs. Conversely, silencing Robo1 expression resulted in an enhanced Shh expression and more HNK-1{sup +} migrating NCCs but reduced Pax7 expression and fewer Slug{sup +} pre-migratory NCCs were observed. In conclusion, we propose that Slit/Robo1 signaling is involved in regulating neural tube development by tightly coordinating cell proliferation and differentiation during neurulation. - Highlights: ► The role of Slit/Robo1 signaling was investigated with chick and mouse models. ► Disturbance of Slit/Robo1 signaling resulted in neural tube defects. ► Slit/Robo1 signaling regulated the proliferation of neural tube cells. ► Slit/Robo1 signaling modulated the differentiation of neural tube cells. ► Slit/Robo1 signaling balanced the proliferation and differentiation of neural tube.« less
40 CFR 63.623 - Standards for new sources.
Code of Federal Regulations, 2013 CFR
2013-07-01
... discharged into the atmosphere from any affected source any gases which contain total fluorides in excess of... shall cause to be discharged into the atmosphere from any affected source any gases which contain total... this subpart shall cause to be discharged into the atmosphere from any affected source any gases which...
40 CFR 63.623 - Standards for new sources.
Code of Federal Regulations, 2011 CFR
2011-07-01
... discharged into the atmosphere from any affected source any gases which contain total fluorides in excess of... shall cause to be discharged into the atmosphere from any affected source any gases which contain total... this subpart shall cause to be discharged into the atmosphere from any affected source any gases which...
40 CFR 63.622 - Standards for existing sources.
Code of Federal Regulations, 2012 CFR
2012-07-01
... discharged into the atmosphere from any affected source any gases which contain total fluorides in excess of... shall cause to be discharged into the atmosphere from any affected source any gases which contain total... this subpart shall cause to be discharged into the atmosphere from any affected source any gases which...
40 CFR 63.623 - Standards for new sources.
Code of Federal Regulations, 2010 CFR
2010-07-01
... discharged into the atmosphere from any affected source any gases which contain total fluorides in excess of... shall cause to be discharged into the atmosphere from any affected source any gases which contain total... this subpart shall cause to be discharged into the atmosphere from any affected source any gases which...
40 CFR 63.622 - Standards for existing sources.
Code of Federal Regulations, 2011 CFR
2011-07-01
... discharged into the atmosphere from any affected source any gases which contain total fluorides in excess of... shall cause to be discharged into the atmosphere from any affected source any gases which contain total... this subpart shall cause to be discharged into the atmosphere from any affected source any gases which...
40 CFR 63.622 - Standards for existing sources.
Code of Federal Regulations, 2013 CFR
2013-07-01
... discharged into the atmosphere from any affected source any gases which contain total fluorides in excess of... shall cause to be discharged into the atmosphere from any affected source any gases which contain total... this subpart shall cause to be discharged into the atmosphere from any affected source any gases which...
40 CFR 63.623 - Standards for new sources.
Code of Federal Regulations, 2014 CFR
2014-07-01
... discharged into the atmosphere from any affected source any gases which contain total fluorides in excess of... shall cause to be discharged into the atmosphere from any affected source any gases which contain total... this subpart shall cause to be discharged into the atmosphere from any affected source any gases which...
40 CFR 63.622 - Standards for existing sources.
Code of Federal Regulations, 2010 CFR
2010-07-01
... discharged into the atmosphere from any affected source any gases which contain total fluorides in excess of... shall cause to be discharged into the atmosphere from any affected source any gases which contain total... this subpart shall cause to be discharged into the atmosphere from any affected source any gases which...
40 CFR 63.623 - Standards for new sources.
Code of Federal Regulations, 2012 CFR
2012-07-01
... discharged into the atmosphere from any affected source any gases which contain total fluorides in excess of... shall cause to be discharged into the atmosphere from any affected source any gases which contain total... this subpart shall cause to be discharged into the atmosphere from any affected source any gases which...
40 CFR 63.622 - Standards for existing sources.
Code of Federal Regulations, 2014 CFR
2014-07-01
... discharged into the atmosphere from any affected source any gases which contain total fluorides in excess of... shall cause to be discharged into the atmosphere from any affected source any gases which contain total... this subpart shall cause to be discharged into the atmosphere from any affected source any gases which...
Larenas-Linnemann, Désirée; Esch, Robert; Plunkett, Greg; Brown, Shannon; Maddox, Daniel; Barnes, Charles; Constable, Derek
2011-11-01
Sublingual immunotherapy (SLIT) has become established in Europe, and its efficacy is being evaluated in the United States. The doses used for SLIT in Europe today are difficult to evaluate, because each manufacturer expresses the potency of its extracts differently. To compare in vitro European SLIT maintenance solutions against US licensed standardized allergenic extract concentrates and to determine the monthly SLIT doses delivered expressed in bioequivalent allergy units ([B]AU). We studied Dermatophagoides pteronyssinus, timothy grass pollen, cat (hair) and short ragweed pollen allergen extracts. The SLIT maintenance solutions of 4 leading European manufacturers and standardized concentrate extracts of 3 US manufacturers were analyzed with the following assays: protein content, relative potency (immunoglobulin E [IgE]-binding enzyme-linked immunosorbent assay [ELISA] inhibition) and major allergen content. The relative monthly allergen dose in (B)AU was calculated for each recommended SLIT schedule. Relative potency was approximately 10 times higher for US concentrate standardized extracts-which are meant to be diluted-than for European SLIT maintenance solutions of D pteronyssinus and timothy grass pollen. For cat (hair) and short ragweed pollen, the difference was less. Measurements of relative potency and major allergen content correlated well. In our assays, European mite extracts contain a very low quantity of Der p 2 compared with US mites. Recommended SLIT doses in Europe vary widely among the manufacturers, but are consistently lower (Eur1) or higher (Eur4) over all four allergens tested. SLIT efficacy probably depends on additional factors apart from the exact dose. SLIT dose finding studies should be done for each product. Copyright © 2011 American College of Allergy. Published by Elsevier Inc. All rights reserved.
Slit-lamp photography and videography with high magnifications
Yuan, Jin; Jiang, Hong; Mao, Xinjie; Ke, Bilian; Yan, Wentao; Liu, Che; Cintrón-Colón, Hector R; Perez, Victor L; Wang, Jianhua
2015-01-01
Purpose To demonstrate the use of the slit-lamp photography and videography with extremely high magnifications for visualizing structures of the anterior segment of the eye. Methods A Canon 60D digital camera with Movie Crop Function was adapted into a Nikon FS-2 slit-lamp to capture still images and video clips of the structures of the anterior segment of the eye. Images obtained using the slit-lamp were tested for spatial resolution. The cornea of human eyes was imaged with the slit-lamp and the structures were compared with the pictures captured using the ultra-high resolution optical coherence tomography (UHR-OCT). The central thickness of the corneal epithelium and total cornea was obtained using the slit-lamp and the results were compared with the thickness obtained using UHR-OCT. Results High-quality ocular images and higher spatial resolutions were obtained by using the slit-lamp with extremely high magnifications and Movie Crop Function, rather than the traditional slit-lamp. The structures and characteristics of the cornea, such as the normal epithelium, abnormal epithelium of corneal intraepithelial neoplasia, LASIK interface, and contact lenses, were clearly visualized using this device. These features were confirmed by comparing the obtained images with those acquired using UHR-OCT. Moreover, the tear film debris on the ocular surface and the corneal nerve in the anterior corneal stroma were also visualized. The thicknesses of the corneal epithelium and total cornea were similar to that measured using UHR-OCT (P < 0.05). Conclusions We demonstrated that the slit-lamp photography and videography with extremely high magnifications allows better visualization of the anterior segment structures of the eye, especially of the epithelium, when compared with the traditional slit-lamp. PMID:26020484
Manzotti, G; Pappacoda, A; Dimatteo, M; Scolari, C; Riario-Sforza, G G; Incorvaia, C
2013-08-01
Specific immunotherapy (SIT) efficacy and safety by subcutaneous (SCIT) and sublingual (SLIT) route is supported by literature data. Pre-coseasonal treatment is currently the more accepted option for pollen immunotherapy in terms of costs and patient's compliance. This retrospective study evaluated the patient's preference concerning subcutaneous or sublingual route in pre-coseasonal treatment. We evaluated 145 patients (79 males, 66 females, age ranging from 14 to 69 years), suffering from moderate-severe rhino-conjunctivitis or mild bronchial asthma and with homogeneous characteristic according to allergic disease severity. We proposed either SLIT, with extracts by different producers, or SCIT with Pollinex 4 (Allergy Therapeutics, Worthing, UK), a product designed for ultra-short administration in 4 injections, highlighting for each kind of SIT the major practical advantages or burdens. Of 145 patients, 72 chose Pollinex 4 SCIT and 73 chose SLIT. SCIT-treated patients received a total of 90 vaccines (18 patients had double course of SCIT). SLIT-treated patients received a total of 87 vaccines (14 patients had double course of SLIT). In the SCIT group, there were 49 males and 23 females; in the SLIT group, there were 30 males and 43 females. Mean age was 36.5 years in SCIT group and 28.5 years in SLIT group. Males preferred SCIT (49 of 72 patients) and females preferred SLIT (43 of 73 patients). No severe reaction was observed either in SCIT or SLIT group. Patients are active subjects in decisional process. Trying to apply in real life the indications coming from guidelines about patient's preference is an important matter. In our patients SCIT with ultra short schedule and SLIT are similarly preferred.
A slit-lamp, which is a specialized magnifying microscope, is used to examine the structures of the eye (including the cornea, iris, vitreous, and retina). The slit-lamp is used to examine, treat (with a laser), ...
Mobilizing slit lamp to the field: A new affordable solution
Farooqui, Javed Hussain; Jorgenson, Richard; Gomaa, Ahmed
2015-01-01
We are describing a simple and affordable design to pack and carry the slit lamp to the field. Orbis staff working on the Flying Eye Hospital (FEH) developed this design to facilitate mobilization of the slit lamp to the field during various FEH programs. The solution involves using a big toolbox, a central plywood apparatus, and foam. These supplies were cut to measure and used to support the slit lamp after being fitted snuggly in the box. This design allows easy and safe mobilization of the slit lamp to remote places. It was developed with the efficient use of space in mind and it can be easily reproduced in developing countries using same or similar supplies. Mobilizing slit lamp will be of great help for staff and institutes doing regular outreach clinical work. PMID:26669342
The double slit experiment and the time reversed fire alarm
NASA Astrophysics Data System (ADS)
Halabi, Tarek
2011-03-01
When both slits of the double slit experiment are open, closing one paradoxically increases the detection rate at some points on the detection screen. Feynman famously warned that temptation to "understand" such a puzzling feature only draws us into blind alleys. Nevertheless, we gain insight into this feature by drawing an analogy between the double slit experiment and a time reversed fire alarm. Much as closing the slit increases probability of a future detection, ruling out fire drill scenarios, having heard the fire alarm, increases probability of a past fire (using Bayesian inference). Classically, Bayesian inference is associated with computing probabilities of past events. We therefore identify this feature of the double slit experiment with a time reversed thermodynamic arrow. We believe that much of the enigma of quantum mechanics is simply due to some variation of time's arrow.
[A micro-silicon multi-slit spectrophotometer based on MEMS technology].
Hao, Peng; Wu, Yi-Hui; Zhang, Ping; Liu, Yong-Shun; Zhang, Ke; Li, Hai-Wen
2009-06-01
A new mini-spectrophotometer was developed by adopting micro-silicon slit and pixel segmentation technology, and this spectrophotometer used photoelectron diode array as the detector by the back-dividing-light way. At first, the effect of the spectral bandwidth on the tested absorbance linear correlation was analyzed. A theory for the design of spectrophotometer's slit was brought forward after discussing the relationships between spectrophotometer spectrum band width and pre-and post-slits width. Then, the integrative micro-silicon-slit, which features small volume, high precision, and thin thickness, was manufactured based on the MEMS technology. Finally, a test was carried on linear absorbance solution by this spectrophotometer. The final result showed that the correlation coefficients were larger than 0.999, which means that the new mini-spectrophotometer with micro-silicon slit pixel segmentation has an obvious linear correlation.
Force transformation in spider strain sensors: white light interferometry
Schaber, Clemens F.; Gorb, Stanislav N.; Barth, Friedrich G.
2012-01-01
Scanning white light interferometry and micro-force measurements were applied to analyse stimulus transformation in strain sensors in the spider exoskeleton. Two compound or ‘lyriform’ organs consisting of arrays of closely neighbouring, roughly parallel sensory slits of different lengths were examined. Forces applied to the exoskeleton entail strains in the cuticle, which compress and thereby stimulate the individual slits of the lyriform organs. (i) For the proprioreceptive lyriform organ HS-8 close to the distal joint of the tibia, the compression of the slits at the sensory threshold was as small as 1.4 nm and hardly more than 30 nm, depending on the slit in the array. The corresponding stimulus forces were as small as 0.01 mN. The linearity of the loading curve seems reasonable considering the sensor's relatively narrow biological intensity range of operation. The slits' mechanical sensitivity (slit compression/force) ranged from 106 down to 13 nm mN−1, and gradually decreased with decreasing slit length. (ii) Remarkably, in the vibration-sensitive lyriform organ HS-10 on the metatarsus, the loading curve was exponential. The organ is thus adapted to the detection of a wide range of vibration amplitudes, as they are found under natural conditions. The mechanical sensitivities of the two slits examined in this organ in detail differed roughly threefold (522 and 195 nm mN−1) in the biologically most relevant range, again reflecting stimulus range fractionation among the slits composing the array. PMID:22031733
SLIT: indications, follow-up, and management.
Dávila, I; Navarro, A; Domínguez-Ortega, J; Alonso, A; Antolín-Amérigo, D; Diéguez, M C; González-Mancebo, E; Martíns, C; Martínez, C; Núñez, B; Prior, N; Rechel, M; Rosado, A; Ruiz-Hornillos, J; Sansosti, A; Torrecillas, M; Jerez, M J
2014-01-01
Specific sublingual immunotherapy (SLIT) has been proved to be a safe and effective approach in respiratory allergy. However, further research is required on aspects such as patient selection, use of optimal dosing, effects on asthma, long-term effects, and management of adverse reactions. In addition, the widely heterogeneous nature of studies on SLIT performed to date and the application of the criteria for subcutaneous immunotherapy make it difficult for the prescribing clinician to draw accurate and useful conclusions. Therefore, the QUASAR Group (QUality in the Administration of SLIT in Allergic Rhinitis), which comprises allergologists with broad clinical experience in SLIT, investigated the latest research findings and available data on this approach. Working parties were formed in 3 different categories: selection of candidates for SLIT, treatment efficacy, and adverse reactions. We performed a PubMed search for articles that were representative of each category and found 850. From these, we finally selected 266 articles, which were reviewed to retrieve data on SLIT. Evidence for each clinical question was graded according to the Oxford classification. The resulting text was evaluated on 3 occasions by all the members of the group until the final version was agreed upon. In this version, we review available evidence on SLIT, particularly with pollens, which is the subject of most articles. In areas where evidence is insufficient, an alternative agreed upon by the members of the QUASAR group is presented. Finally, we propose algorithms for selecting candidates for SLIT and for management of adverse events.
NASA Astrophysics Data System (ADS)
Yoon, Young Zoon; Kim, Hyochul; Park, Yeonsang; Kim, Jineun; Lee, Min Kyung; Kim, Un Jeong; Roh, Young-Geun; Hwang, Sung Woo
2016-09-01
Wearable devices often employ optical sensors, such as photoplethysmography sensors, for detecting heart rates or other biochemical factors. Pulse waveforms, rather than simply detecting heartbeats, can clarify arterial conditions. However, most optical sensor designs require close skin contact to reduce power consumption while obtaining good quality signals without distortion. We have designed a detection-gap-independent optical sensor array using divergence-beam-controlled slit lasers and distributed photodiodes in a pulse-detection device wearable over the wrist's radial artery. It achieves high biosignal quality and low power consumption. The top surface of a vertical-cavity surface-emitting laser of 850 nm wavelength was covered by Au film with an open slit of width between 500 nm and 1500 nm, which generated laser emissions across a large divergence angle along an axis orthogonal to the slit direction. The sensing coverage of the slit laser diode (LD) marks a 50% improvement over nonslit LD sensor coverage. The slit LD sensor consumes 100% more input power than the nonslit LD sensor to obtain similar optical output power. The slit laser sensor showed intermediate performance between LD and light-emitting diode sensors. Thus, designing sensors with multiple-slit LD arrays can provide useful and convenient ways for incorporating optical sensors in wrist-wearable devices.
A microbeam slit system for high beam currents
NASA Astrophysics Data System (ADS)
Vallentin, T.; Moser, M.; Eschbaumer, S.; Greubel, C.; Haase, T.; Reichart, P.; Rösch, T.; Dollinger, G.
2015-04-01
A new microbeam slit system for high beam currents of 10 μA was built up to improve the brightness transport of a proton beam with a kinetic energy of up to 25 MeV into the microprobe SNAKE. The new slit system features a position accuracy of less than 1 μm under normal operating conditions and less than 2 μm if the beam is switched on and off. The thermal management with a powerful watercooling and potential-free thermocouple feedback controlled heating cables is optimized for constant slit aperture at thermal power input of up to 250 W. The transparent zone is optimized to 0.7 μm due to the use of tungsten formed to a cylindrical surface with a radius r = 100 mm and mechanically lapped surface to minimize small angle scattering effects and to minimize the number of ions passing the slits with low energy loss. Electrical isolation of the slit tip enables slit current monitoring, e.g. for tandem accelerator feedback control. With the ability to transport up to 10 μA of protons with the new microslit system, the brightness Bexp transported into the microprobe was increased by a factor of 2 compared to low current injection using the old slit system.
Diagnostic system for profiling micro-beams
Elmer, John W.; Palmer, Todd A.; Teruya, Alan T.; Walton, Chris C.
2007-10-30
An apparatus for characterization of a micro beam comprising a micro modified Faraday cup assembly including a first layer of material, a second layer of material operatively connected to the first layer of material, a third layer of material operatively connected to the second layer of material, and a fourth layer of material operatively connected to the third layer of material. The first layer of material comprises an electrical conducting material and has at least one first layer radial slit extending through the first layer. An electrical ground is connected to the first layer. The second layer of material comprises an insulating material and has at least one second layer radial slit corresponding to the first layer radial slit in the first layer of material. The second layer radial slit extends through the second layer. The third layer of material comprises a conducting material and has at least one third layer radial slit corresponding to the second layer radial slit in the second layer of material. The third layer radial slit extends through the third layer. The fourth layer of material comprises an electrical conducting material but does not have slits. An electrical measuring device is connected to the fourth layer. The micro modified Faraday cup assembly is positioned to be swept by the micro beam.
Scatter Reduction In Conventional Radiographic Tomography Using Rotating Apertures
NASA Astrophysics Data System (ADS)
Rudin, Stephen; Bednarek, Daniel R.
1981-08-01
Since images in conventional radiographic tomography are in-herently low in subject contrast, it is essential that scattered radiation be prevented from reaching the image receptor. Scanning beam or slit radiographic techniques are known to be the most efficient scatter elimination methods, yet have been inapplicable to this area of radiography. In this work it is shown that the scanning beam method using rotating aperture wheel (RAW) devices can be used in conventional tomography. One coder wheel between the x-ray tube and patient and two scatter discriminator wheels between the patient and image recep-tor form sections of the RAW "projection cone" with the lines of radia-tion from the x-ray source forming the "flux pyramid." As long as the projection cone follows the motion of the x-ray flux pyramid (with the ratios of the distances between the x-ray source, RAWs, patient, and image receptor kept constant throughout the motion) any RAW pattern may be used. Simple relations are given which describe the geometric constraints for various tomographic motions. As in any application of scanning slit techniques, it is possible to use the excellent scatter elimination capabilities of a RAW device either to improve image contrast or to reduce patient dose.
Inexpensive Masks for Film Deposition
NASA Technical Reports Server (NTRS)
Conley, W. R.
1986-01-01
Sputtered sprayed lines less than 2 millimeters wide made by superimposing masks with partially overlapping openings. Slits first cut in masks by stamping or other economical process. Masks superimposed so slits define new openings narrower than original slits.
AKARI/IRC NEAR-INFRARED SPECTRAL ATLAS OF GALACTIC PLANETARY NEBULAE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ohsawa, Ryou; Onaka, Takashi; Sakon, Itsuki
2016-04-15
Near-infrared (2.5–5.0 μm) low-resolution (λ/Δλ ∼ 100) spectra of 72 Galactic planetary nebulae (PNe) were obtained with the Infrared Camera (IRC) in the post-helium phase. The IRC, equipped with a 1′ × 1′ window for spectroscopy of a point source, was capable of obtaining near-infrared spectra in a slit-less mode without any flux loss due to a slit. The spectra show emission features including hydrogen recombination lines and the 3.3–3.5 μm hydrocarbon features. The intensity and equivalent width of the emission features were measured by spectral fitting. We made a catalog providing unique information on the investigation of the near-infrared emission ofmore » PNe. In this paper, details of the observations and characteristics of the catalog are described.« less
Characterization and optimization for detector systems of IGRINS
NASA Astrophysics Data System (ADS)
Jeong, Ueejeong; Chun, Moo-Young; Oh, Jae Sok; Park, Chan; Yuk, In-Soo; Oh, Heeyoung; Kim, Kang-Min; Ko, Kyeong Yeon; Pavel, Michael D.; Yu, Young Sam; Jaffe, Daniel T.
2014-07-01
IGRINS (Immersion GRating INfrared Spectrometer) is a high resolution wide-band infrared spectrograph developed by the Korea Astronomy and Space Science Institute (KASI) and the University of Texas at Austin (UT). This spectrograph has H-band and K-band science cameras and a slit viewing camera, all three of which use Teledyne's λc~2.5μm 2k×2k HgCdTe HAWAII-2RG CMOS detectors. The two spectrograph cameras employ science grade detectors, while the slit viewing camera includes an engineering grade detector. Teledyne's cryogenic SIDECAR ASIC boards and JADE2 USB interface cards were installed to control those detectors. We performed experiments to characterize and optimize the detector systems in the IGRINS cryostat. We present measurements and optimization of noise, dark current, and referencelevel stability obtained under dark conditions. We also discuss well depth, linearity and conversion gain measurements obtained using an external light source.
Martina, E.F.
1958-10-14
An improved pulsed ion source of the type where the gas to be ionized is released within the source by momentary heating of an electrode occluded with the gas is presented. The other details of the ion source construction include an electron emitting filament and a positive reference grid, between which an electron discharge is set up, and electrode means for withdrawing the ions from the source. Due to the location of the gas source behind the electrode discharge region, and the positioning of the vacuum exhaust system on the opposite side of the discharge, the released gas is drawn into the electron discharge and ionized in accurately controlled amounts. Consequently, the output pulses of the ion source may be accurately controlled.
Improvement of unbalanced illumination induced telecentricity within the exposure slit
NASA Astrophysics Data System (ADS)
Jang, Jonghoon; Lee, ByeongSoo; Kang, Young Seog; Chang, Chansam; Kong, Jeong-Heung; Kim, Young Ha; Bouman, Wim; de Graaf, Roelof; Weichselbaum, Stefan; Droste, Richard; de Boeij, Wim P.; van Bussel, Bart; Neefs, Patrick; Rijke, Arij
2016-03-01
Adjustment and control of the illumination pupil asymmetry is relevant for wafer alignment and overlay of lithography tools. Pupil asymmetries can cause a tilt in aerial image (Aerial Image Tilt, or AIT). This AIT, combined with a focus offset, leads to a horizontal image shift. Pupil asymmetries can be related to a shift of the entire illumination pupil (geometrical telecentricity) caused by illuminator misalign. Another type of pupil asymmetry is energetic imbalance (quantified by pupil Center of Gravity, COG). The scanner can show pupil variation across the exposure slit. In general the COG at the edge of the slit is often worse than in the center part of the slit. Recently, ASML has released the NXT:1980Di that is equipped with an enhanced illuminator to improve pupil COG variation across the slit. In this paper we explore the performance of this scanner system and show that the AIT variation across the slit is also reduced significantly.
Generalization of the Schwarz–Christoffel mapping to multiply connected polygonal domains
Vasconcelos, Giovani L.
2014-01-01
A generalization of the Schwarz–Christoffel mapping to multiply connected polygonal domains is obtained by making a combined use of two preimage domains, namely, a rectilinear slit domain and a bounded circular domain. The conformal mapping from the circular domain to the polygonal region is written as an indefinite integral whose integrand consists of a product of powers of the Schottky-Klein prime functions, which is the same irrespective of the preimage slit domain, and a prefactor function that depends on the choice of the rectilinear slit domain. A detailed derivation of the mapping formula is given for the case where the preimage slit domain is the upper half-plane with radial slits. Representation formulae for other canonical slit domains are also obtained but they are more cumbersome in that the prefactor function contains arbitrary parameters in the interior of the circular domain. PMID:24910523
Generalization of the Schwarz-Christoffel mapping to multiply connected polygonal domains.
Vasconcelos, Giovani L
2014-06-08
A generalization of the Schwarz-Christoffel mapping to multiply connected polygonal domains is obtained by making a combined use of two preimage domains, namely, a rectilinear slit domain and a bounded circular domain. The conformal mapping from the circular domain to the polygonal region is written as an indefinite integral whose integrand consists of a product of powers of the Schottky-Klein prime functions, which is the same irrespective of the preimage slit domain, and a prefactor function that depends on the choice of the rectilinear slit domain. A detailed derivation of the mapping formula is given for the case where the preimage slit domain is the upper half-plane with radial slits. Representation formulae for other canonical slit domains are also obtained but they are more cumbersome in that the prefactor function contains arbitrary parameters in the interior of the circular domain.
NASA Astrophysics Data System (ADS)
Ueyama, Hiroya; Maeno, Tsuyoshi; Hirata, Akimasa; Wang, Jianqing; Fujiwara, Osamu
Electromagnetic disturbances for vehicle-mounted radios are well known to be caused mainly by conduction noise currents flowing out wire harnesses from printed circuit boards (PCBs) having a common ground layer with slits. In this study, in order to investigate how ground-layer slits affect the above conduction noise currents, we paid FM band induced voltages or crosstalks on the trace connected to the wire harnesss, and simulated with the FDTD method the crosstalk levels between two traces perpendicularly fabricated on three kinds of simple PCBs with different ground-layer slits, which were compared with measurement in the frequency range from 10 MHz to 1 GHz. As a result, we could confirm that the FDTD calculation approximately agrees with the measured results, and also that the crosstalk levels do not always increase with the slit number, which can be reduced by the slit layout.
Martina, E.F.
1958-04-22
An improved ion source particularly adapted to provide an intense beam of ions with minimum neutral molecule egress from the source is described. The ion source structure includes means for establishing an oscillating electron discharge, including an apertured cathode at one end of the discharge. The egress of ions from the source is in a pencil like beam. This desirable form of withdrawal of the ions from the plasma created by the discharge is achieved by shaping the field at the aperture of the cathode. A tubular insulator is extended into the plasma from the aperture and in cooperation with the electric fields at the cathode end of the discharge focuses the ions from the source,
Polarized hydrogen/deuterium molecules
NASA Astrophysics Data System (ADS)
Shestakov, Yu V.; Nikolenko, D. M.; Rachek, I. A.; Sadykov, R. Sh; Toporkov, D. K.; Yurchenko, A. V.; Zevakov, S. A.
2017-12-01
The prototype of a polarized molecular hydrogen/deuterium source which is based on the classical Stern-Gerlach separation scheme has been tested at the Budker Institute of Nuclear Physics (BINP), Novosibirsk. It consists of the circular slit nozzle cooled down to 6.5 K and the two superconducting sextupole magnets. The flux of polarized hydrogen molecules of 3·1012 mol/s was measured for a total gas flow through the nozzle of 5·10-2 Torr·l/s. The obtained results will be used to develop a much more intense source of polarized molecules.
[The study on the characteristics and particle densities of lightning discharge plasma].
Wang, Jie; Yuan, Ping; Zhang, Hua-ming; Shen, Xiao-zhi
2008-09-01
According to the wavelengths, relative intensities and transition parameters of lines in cloud-to-ground lightning spectra obtained by a slit-less spectrograph in Qinghai province and Xizang municipality, and by theoretical calculations of plasma, the average temperature and electron density for individual lightning discharge channel were calculated, and then, using Saha equations, electric charge conservation equations and particle conservation equations, the particle densities of every ionized-state, the mass density, pressure and the average ionization degree were obtained. Moreover, the average ionization degree and characteristics of particle distributions in each lightning discharge channel were analyzed. Local thermodynamic equilibrium and an optically thin emitting gas were assumed in the calculations. The result shows that the characteristics of lightning discharge plasma have strong relationships with lightning intensities. For a certain return stroke channel, both temperatures and electron densities of different positions show tiny trend of falling away with increasing height along the discharge channel. Lightning channels are almost completely ionized, and the first ionized particles occupy the main station while N II has the highest particle density. On the other hand, the relative concentrations of N II and O II are near a constant in lightning channels with different intensities. Generally speaking, the more intense the lightning discharge, the higher are the values of channel temperature, electron density and relative concentrations of highly ionized particles, but the lower the concentration of the neutral atoms. After considering the Coulomb interactions between positive and negative particles in the calculations, the results of ionization energies decrease, and the particle densities of atoms and first ionized ions become low while high-ionized ions become high. At a temperature of 28000 K, the pressure of the discharge channel due to electrons, atoms and ions is about 10 atmospheric pressure, and it changes for different lightning stroke with different intensity. The mass density of channel is lower and changes from 0.01 to 0.1 compared to the mass density of air at standard temperature and pressure (STP).
Emission Spectroscopy of the 4X Source Discharge With and Without N 2 Gas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, Horace Vernon
2016-01-14
This tech note summarizes the December, 1988 emission spectroscopy measurements made on the 4X source discharge with and without N₂ gas added to the H + Cs discharge. This study is motivated by the desire to understand why small amounts of N₂ gas added to the source discharge results in a reduction in the H⁻ beam noise. The beneficial effect of N₂ gas on H⁻ beam noise was first discovered by Bill Ingalls and Stu Orbesen on the ATS SAS source. For the 4X source the observed effect is that when N2 gas is added to the discharge the H⁻more » beam noise is reduced about a factor of 2.« less
Tsujino, Jiromaru; Harada, Yoshiki; Ihara, Shigeru; Kasahara, Kohei; Shimizu, Masanori; Ueoka, Tetsugi
2004-04-01
Ultrasonic high-frequency complex vibrations are effective for various ultrasonic high-power applications. Three types of ultrasonic complex vibration system with a welding tip vibrating elliptical to circular locus for packaging in microelectronics were studied. The complex vibration sources are using (1) a longitudinal-torsional vibration converter with diagonal slits that is driven only by a longitudinal vibration source, (2) a complex transverse vibration rod with several stepped parts that is driven by two longitudinal vibration source crossed at a right angle and (3) a longitudinal vibration circular disk and three longitudinal transducers that are installed at the circumference of the disk.
Single-Slit Diffraction and the Uncertainty Principle
ERIC Educational Resources Information Center
Rioux, Frank
2005-01-01
A theoretical analysis of single-slit diffraction based on the Fourier transform between coordinate and momentum space is presented. The transform between position and momentum is used to illuminate the intimate relationship between single-slit diffraction and uncertainty principle.
Atmospheric sampling glow discharge ionization source
McLuckey, Scott A.; Glish, Gary L.
1989-01-01
An atmospheric sampling glow discharge ionization source that can be used in combination with an analytical instrument which operates at high vacuum, such as a mass spectrometer. The atmospheric sampling glow discharge ionization source comprises a chamber with at least one pair of electrodes disposed therein, an inlet for a gaseous sample to be analyzed and an outlet communicating with an analyzer which operates at subatmospheric pressure. The ionization chamber is maintained at a pressure below atmospheric pressure, and a voltage difference is applied across the electrodes to induce a glow discharge between the electrodes, so that molecules passing through the inlet are ionized by the glow discharge and directed into the analyzer. The ionization source accepts the sample under atmospheric pressure conditions and processes it directly into the high vacuum instrument, bridging the pressure gap and drawing off unwanted atmospheric gases. The invention also includes a method for analyzing a gaseous sample using the glow discharge ionization source described above.
Optical Alignment and Diffraction Analysis for AIRES: An Airborne Infrared Echelle Spectrometer
NASA Technical Reports Server (NTRS)
Haas, Michael R.; Fonda, Mark (Technical Monitor)
2002-01-01
The optical design is presented for a long-slit grating spectrometer known as AIRES (Airborne InfraRed Echelle Spectrometer). The instrument employs two gratings in series: a small order sorter and a large steeply blazed echelle. The optical path includes four pupil and four field stops, including two narrow slits. A detailed diffraction analysis is performed using GLAD by Applied Optics Research to evaluate critical trade-offs between optical throughput, spectral resolution, and system weight and volume. The effects of slit width, slit length, oversizing the second slit relative to the first, on- vs off-axis throughput, and clipping at the pupil stops and other optical elements are discussed.
NASA Astrophysics Data System (ADS)
Sasoh, A.; Mizutani, K.; Iwakawa, A.
2017-06-01
Ion acceleration through a slowly diverging magnetic nozzle between a ring anode and a hollow cathode set on the axis of symmetry has been realized. Xenon was supplied as the propellant gas from an annular slit along the inner surface of the ring anode so that it was ionized near the anode, and the applied electric potential was efficiently transformed to an ion kinetic energy. As an electrostatic thruster, within the examined operation conditions, the thrust, F, almost scaled with the propellant mass flow rate; the discharge current, Jd, increased with the discharge voltage, Vd. An important characteristic was that the thrust also exhibited electromagnetic acceleration performance, i.e., the so-called "swirl acceleration," in which F ≅JdB Ra /√{2 }, where B and Ra were a magnetic field and an anode inner radius, respectively. Such a unique thruster performance combining both electrostatic and electromagnetic accelerations is expected to be useful as another option for in-space electric propulsion in its broad functional diversity.
Screen for Slit/Robo signaling in trunk neural cells reveals new players.
Martinez, Darwin; Zuhdi, Nora; Reyes, Michelle; Ortega, Blanca; Giovannone, Dion; Lee, Vivian M; de Bellard, Maria Elena
2018-06-01
Slits ligands and their Robo receptors are involved in quite disparate cell signaling pathways that include axon guidance, cell proliferation, cell motility and angiogenesis. Neural crest cells emerge by delamination from neural cells in the dorsal neural tube, and give rise to various components of the peripheral nervous system in vertebrates. It is well established that these cells change from a non-migratory to a highly migratory state allowing them to reach distant regions before they differentiate. However, but the mechanism controlling this delamination and subsequent migration are still not fully understood. The repulsive Slit ligand family members, have been classified also as true tumor suppressor molecules. The present study explored in further detail what possible Slit/Robo signals are at play in the trunk neural cells and neural crest cells by carrying out a microarray after Slit2 gain of function in trunk neural tubes. We found that in addition to molecules known to be downstream of Slit/Robo signaling, there were a large set of molecules known to be important in maintaining cells in non-motile, epithelia phenotype. Furthermore, we found new molecules previously not associated with Slit/Robo signaling: cell proliferation markers, Ankyrins and RAB intracellular transporters. Our findings suggest that neural crest cells use and array of different Slit/Robo pathways during their transformation from non-motile to highly motile cells. Copyright © 2018. Published by Elsevier B.V.
Enhanced modified faraday cup for determination of power density distribution of electron beams
Elmer, John W.; Teruya, Alan T.
2001-01-01
An improved tomographic technique for determining the power distribution of an electron or ion beam using electron beam profile data acquired by an enhanced modified Faraday cup to create an image of the current density in high and low power ion or electron beams. A refractory metal disk with a number of radially extending slits, one slit being about twice the width of the other slits, is placed above a Faraday cup. The electron or ion beam is swept in a circular pattern so that its path crosses each slit in a perpendicular manner, thus acquiring all the data needed for a reconstruction in one circular sweep. The enlarged slit enables orientation of the beam profile with respect to the coordinates of the welding chamber. A second disk having slits therein is positioned below the first slit disk and inside of the Faraday cup and provides a shield to eliminate the majority of secondary electrons and ions from leaving the Faraday cup. Also, a ring is located below the second slit disk to help minimize the amount of secondary electrons and ions from being produced. In addition, a beam trap is located in the Faraday cup to provide even more containment of the electron or ion beam when full beam current is being examined through the center hole of the modified Faraday cup.
Durham, Stephen R; Creticos, Peter S; Nelson, Harold S; Li, Ziliang; Kaur, Amarjot; Meltzer, Eli O; Nolte, Hendrik
2016-10-01
Data comparing the treatment effect of allergy immunotherapy and pharmacotherapy are lacking. We sought to indirectly compare the treatment effect of sublingual immunotherapy (SLIT)-tablets with pharmacotherapy for seasonal allergic rhinitis (SAR) and perennial allergic rhinitis (PAR). Pooled data from randomized, double-blind, placebo-controlled trials for the clinical development programs of selected allergic rhinitis treatments were evaluated. Total nasal symptom scores (TNSSs) relative to placebo were compared. Subjects scored symptoms daily during entire pollen seasons in 6 timothy grass SLIT-tablet trials (n = 3094) and 2 ragweed SLIT-tablet trials (n = 658) and during the last 8 weeks of treatment in 2 house dust mite (HDM) SLIT-tablet trials (n = 1768). Subjects scored symptoms daily in 7 montelukast (10 mg, n = 6799), 9 desloratadine (5 mg, n = 4455), and 8 mometasone furoate nasal spray (MFNS; 200 μg daily, n = 2140) SAR or PAR trials. SLIT-tablet trials allowed rescue medication use, whereas most pharmacotherapy trials did not. A fixed-effect meta-analysis method estimated differences in on-treatment average TNSSs. In grass and ragweed SLIT-tablet trials, overall improvement in TNSSs relative to placebo was 16.3% and 17.1%, respectively. In HDM SLIT-tablet trials, TNSS overall improvement relative to placebo was 16.1%. In the montelukast, desloratadine, and MFNS trials, TNSS overall improvement relative to placebo was 5.4%, 8.5%, and 22.2%, respectively, for SAR trials, and 3.7%, 4.8%, and 11.2%, respectively, for PAR trials. Although comparisons were limited by study design heterogeneity and use of rescue medications in SLIT-tablet trials, effects on nasal symptoms with timothy grass and ragweed SLIT-tablets were nearly as great as with MFNS and numerically greater than with montelukast and desloratadine for SAR. HDM SLIT-tablet effects were numerically greater than all pharmacotherapies for PAR. SLIT-tablets offer the additional benefit of long-term efficacy. Copyright © 2016 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.
Contralateral migration of oculomotor neurons is regulated by Slit/Robo signaling.
Bjorke, Brielle; Shoja-Taheri, Farnaz; Kim, Minkyung; Robinson, G Eric; Fontelonga, Tatiana; Kim, Kyung-Tai; Song, Mi-Ryoung; Mastick, Grant S
2016-10-22
Oculomotor neurons develop initially like typical motor neurons, projecting axons out of the ventral midbrain to their ipsilateral targets, the extraocular muscles. However, in all vertebrates, after the oculomotor nerve (nIII) has reached the extraocular muscle primordia, the cell bodies that innervate the superior rectus migrate to join the contralateral nucleus. This motor neuron migration represents a unique strategy to form a contralateral motor projection. Whether migration is guided by diffusible cues remains unknown. We examined the role of Slit chemorepellent signals in contralateral oculomotor migration by analyzing mutant mouse embryos. We found that the ventral midbrain expresses high levels of both Slit1 and 2, and that oculomotor neurons express the repellent Slit receptors Robo1 and Robo2. Therefore, Slit signals are in a position to influence the migration of oculomotor neurons. In Slit 1/2 or Robo1/2 double mutant embryos, motor neuron cell bodies migrated into the ventral midbrain on E10.5, three days prior to normal migration. These early migrating neurons had leading projections into and across the floor plate. In contrast to the double mutants, embryos which were mutant for single Slit or Robo genes did not have premature migration or outgrowth on E10.5, demonstrating a cooperative requirement of Slit1 and 2, as well as Robo1 and 2. To test how Slit/Robo midline repulsion is modulated, we found that the normal migration did not require the receptors Robo3 and CXCR4, or the chemoattractant, Netrin 1. The signal to initiate contralateral migration is likely autonomous to the midbrain because oculomotor neurons migrate in embryos that lack either nerve outgrowth or extraocular muscles, or in cultured midbrains that lacked peripheral tissue. Overall, our results demonstrate that a migratory subset of motor neurons respond to floor plate-derived Slit repulsion to properly control the timing of contralateral migration.
Are snakes particles or waves? Scattering of a limbless locomotor through a single slit
NASA Astrophysics Data System (ADS)
Qian, Feifei; Dai, Jin; Gong, Chaohui; Choset, Howie; Goldman, Daniel
Droplets on vertically vibrated fluid surfaces can walk and diffract through a single slit by a pilot wave hydrodynamic interaction [Couder, 2006; Bush, 2015]. Inspired by the correspondence between emergent macroscale dynamics and phenomena in quantum systems, we tested if robotic snakes, which resemble wave packets, behave emergently like particles or waves when interacting with an obstacle. In lab experiments and numerical simulations we measured how a multi-module snake-like robot swam through a single slit. We controlled the snake undulation gait as a fixed serpenoid traveling wave pattern with varying amplitude and initial phase, and we examined the snake trajectory as it swam through a slit with width d. Robot trajectories were straight before interaction with the slit, then exited at different scattering angle θ after the interaction due to a complex interaction of the body wave with the slit. For fixed amplitude and large d, the snake passed through the slit with minimal interaction and theta was ~ 0 . For sufficiently small d, θ was finite and bimodally distributed, depending on the initial phase. For intermediate d, θ was sensitive to initial phase, and the width of the distribution of θ increased with decreasing d.
A new slit lamp-based technique for anterior chamber angle estimation.
Gispets, Joan; Cardona, Genís; Tomàs, Núria; Fusté, Cèlia; Binns, Alison; Fortes, Miguel A
2014-06-01
To design and test a new noninvasive method for anterior chamber angle (ACA) estimation based on the slit lamp that is accessible to all eye-care professionals. A new technique (slit lamp anterior chamber estimation [SLACE]) that aims to overcome some of the limitations of the van Herick procedure was designed. The technique, which only requires a slit lamp, was applied to estimate the ACA of 50 participants (100 eyes) using two different slit lamp models, and results were compared with gonioscopy as the clinical standard. The Spearman nonparametric correlation between ACA values as determined by gonioscopy and SLACE were 0.81 (p < 0.001) and 0.79 (p < 0.001) for each slit lamp. Sensitivity values of 100 and 87.5% and specificity values of 75 and 81.2%, depending on the slit lamp used, were obtained for the SLACE technique as compared with gonioscopy (Spaeth classification). The SLACE technique, when compared with gonioscopy, displayed good accuracy in the detection of narrow angles, and it may be useful for eye-care clinicians without access to expensive alternative equipment or those who cannot perform gonioscopy because of legal constraints regarding the use of diagnostic drugs.
Broad-beam high-current dc ion source based on a two-stage glow discharge plasma.
Vizir, A V; Oks, E M; Yushkov, G Yu
2010-02-01
We have designed, made, and demonstrated a broad-beam, dc, ion source based on a two-stage, hollow-cathode, and glow discharges plasma. The first-stage discharge (auxiliary discharge) produces electrons that are injected into the cathode cavity of a second-stage discharge (main discharge). The electron injection causes a decrease in the required operating pressure of the main discharge down to 0.05 mTorr and a decrease in required operating voltage down to about 50 V. The decrease in operating voltage of the main discharge leads to a decrease in the fraction of impurity ions in the ion beam extracted from the main gas discharge plasma to less than 0.2%. Another feature of the source is a single-grid accelerating system in which the ion accelerating voltage is applied between the plasma itself and the grid electrode. The source has produced steady-state Ar, O, and N ion beams of about 14 cm diameter and current of more than 2 A at an accelerating voltage of up to 2 kV.
Towards higher stability of resonant absorption measurements in pulsed plasmas.
Britun, Nikolay; Michiels, Matthieu; Snyders, Rony
2015-12-01
Possible ways to increase the reliability of time-resolved particle density measurements in pulsed gaseous discharges using resonant absorption spectroscopy are proposed. A special synchronization, called "dynamic source triggering," between a gated detector and two pulsed discharges, one representing the discharge of interest and another being used as a reference source, is developed. An internal digital delay generator in the intensified charge coupled device camera, used at the same time as a detector, is utilized for this purpose. According to the proposed scheme, the light pulses from the reference source follow the gates of detector, passing through the discharge of interest only when necessary. This allows for the utilization of short-pulse plasmas as reference sources, which is critical for time-resolved absorption analysis of strongly emitting pulsed discharges. In addition to dynamic source triggering, the reliability of absorption measurements can be further increased using simultaneous detection of spectra relevant for absorption method, which is also demonstrated in this work. The proposed methods are illustrated by the time-resolved measurements of the metal atom density in a high-power impulse magnetron sputtering (HiPIMS) discharge, using either a hollow cathode lamp or another HiPIMS discharge as a pulsed reference source.
Transition from a spectrum filter to a polarizer in a metallic nano-slit array
Zhou, Jing; Guo, L. Jay
2014-01-01
The transition from a spectrum filter (resonant transmission) to a polarizer (broadband transmission) for TM polarized light is observed in a metallic nano-slit array as period is decreased. A theoretical model is developed and shows that the spectrum filter behavior is caused by the coupled slit/grating resonance. With decreasing period, the slit resonance is decoupled from the grating resonance, which then dominates the transmission spectrum and broadens the transmission peak. With further reducing period, the slit resonance diminishes and the peak spectrum transforms to a broadband transmission. This effect is the basis for the operation of wire grid polarizers. The transition is explained by the change of the impedance to the incoming wave. PMID:24402443
Transition from a spectrum filter to a polarizer in a metallic nano-slit array.
Zhou, Jing; Guo, L Jay
2014-01-09
The transition from a spectrum filter (resonant transmission) to a polarizer (broadband transmission) for TM polarized light is observed in a metallic nano-slit array as period is decreased. A theoretical model is developed and shows that the spectrum filter behavior is caused by the coupled slit/grating resonance. With decreasing period, the slit resonance is decoupled from the grating resonance, which then dominates the transmission spectrum and broadens the transmission peak. With further reducing period, the slit resonance diminishes and the peak spectrum transforms to a broadband transmission. This effect is the basis for the operation of wire grid polarizers. The transition is explained by the change of the impedance to the incoming wave.
Transition from a spectrum filter to a polarizer in a metallic nano-slit array
NASA Astrophysics Data System (ADS)
Zhou, Jing; Guo, L. Jay
2014-01-01
The transition from a spectrum filter (resonant transmission) to a polarizer (broadband transmission) for TM polarized light is observed in a metallic nano-slit array as period is decreased. A theoretical model is developed and shows that the spectrum filter behavior is caused by the coupled slit/grating resonance. With decreasing period, the slit resonance is decoupled from the grating resonance, which then dominates the transmission spectrum and broadens the transmission peak. With further reducing period, the slit resonance diminishes and the peak spectrum transforms to a broadband transmission. This effect is the basis for the operation of wire grid polarizers. The transition is explained by the change of the impedance to the incoming wave.
UVSTAR: An imaging spectrograph with telescope for the Shuttle Hitchhiker-M platform
NASA Technical Reports Server (NTRS)
Stalio, Roberto; Sandel, Bill R.; Broadfoot, A. Lyle
1993-01-01
UVSTAR is an EUV spectral imager intended as a facility instrument devoted to solar system and astronomy studies. It covers the wavelength range of 500 to 1250 A, with sufficient spectral resolution to separate emission lines and to form spectrally resolved images of extended plasma sources. Targets include the Io plasma torus at Jupiter, hot stars, planetary nebulae and bright galaxies. UVSTAR consists of a pair of telescopes and concave grating spectrographs that cover the overlapping spectral ranges of 500-900 and 850-1250 A. The telescopes use two 30 cm diameter off-axis paraboloids having focal length of 1.5 m. An image of the target is formed at the entrance slits of the two concave grating spectrographs. The gratings provide dispersion and re-image the slits at the detectors, intensified CCD's. The readout format of the detectors can be chosen by computer, and three slit widths are selectable to adapt the instrument to specific tasks. UVSTAR has internal gimbals which allow rotation of plus or minus 3 deg about each of two axes. Dedicated finding and tracking telescopes will acquire and track the target after rough pointing is achieved by orienting the Orbiter. Responsibilities for implementation and utilization of UVSTAR are shared by groups in Italy and the U.S. UVSTAR is scheduled for flight in early 1995, timed for an opportunity to observe the Jovian system.
NASA Astrophysics Data System (ADS)
Kawashima, Natsumi; Nogo, Kosuke; Hosono, Satsuki; Nishiyama, Akira; Wada, Kenji; Ishimaru, Ichiro
2016-11-01
The use of the wide-field-stop and beam-expansion method for sensitivity enhancement of one-shot Fourier spectroscopy is proposed to realize health care sensors installed in smartphones for daily monitoring. When measuring the spectral components of human bodies noninvasively, diffuse reflected light from biological membranes is too weak for detection using conventional hyperspectral cameras. One-shot Fourier spectroscopy is a spatial phase-shift-type interferometer that can determine the one-dimensional spectral characteristics from a single frame. However, this method has low sensitivity, so that only the spectral characteristics of light sources with direct illumination can be obtained, because a single slit is used as a field stop. The sensitivity of the proposed spectroscopic method is improved by using the wide-field-stop and beam-expansion method. The use of a wider field stop slit width increases the detected light intensity; however, this simultaneously narrows the diffraction angle. The narrower collimated objective beam diameter degrades the visibility of interferograms. Therefore, a plane-concave cylindrical lens between the objective plane and the single slit is introduced to expand the beam diameter. The resulting sensitivity improvement achieved when using the wide-field-stop and beam-expansion method allows the spectral characteristics of hemoglobin to be obtained noninvasively from a human palm using a midget lamp.
Regeneration and maintenance of the planarian midline is regulated by a slit orthologue.
Cebrià, Francesc; Guo, Tingxia; Jopek, Jessica; Newmark, Phillip A
2007-07-15
Several families of evolutionarily conserved axon guidance cues orchestrate the precise wiring of the nervous system during embryonic development. The remarkable plasticity of freshwater planarians provides the opportunity to study these molecules in the context of neural regeneration and maintenance. Here we characterize a homologue of the Slit family of guidance cues from the planarian Schmidtea mediterranea. Smed-slit is expressed along the planarian midline, in both dorsal and ventral domains. RNA interference (RNAi) targeting Smed-slit results in the collapse of many newly regenerated tissues at the midline; these include the cephalic ganglia, ventral nerve cords, photoreceptors, and the posterior digestive system. Surprisingly, Smed-slit RNAi knockdown animals also develop morphologically distinguishable, ectopic neural structures near the midline in uninjured regions of intact and regenerating planarians. These results suggest that Smed-slit acts not only as a repulsive cue required for proper midline formation during regeneration but that it may also act to regulate the behavior of neural precursors at the midline in intact planarians.
Srinivasan, Sathish; Rootman, David S
2007-09-01
To describe a new slit-lamp technique for draining interface fluid to manage complete donor disc detachments following Descemet's stripping (automated) endothelial keratoplasty (DSEK/DSAEK). Interventional case series. Five DSEK/DSAEK patients presented on the first postoperative day with complete detachment of the donor lenticule. Slit-lamp biomicroscopy showed interface fluid preventing attachment of the donor disc to the host stromal bed. A new slit-lamp technique is described to drain the interface fluid. This technique involved completely filling the anterior chamber with an air bubble using a 30-gauge needle on a 3 ml syringe. Following this, a 0.12 forceps was used to open the inferior mid-peripheral corneal drainage slit to drain the interface fluid. This technique was successful in draining the interface fluid in all five patients, leading to immediate complete reattachment of the donor disc. Donor disc detachments following DSEK/DSAEK can be successfully managed by this slit-lamp technique of draining the interface fluid.
2000-08-01
management for NPS. The State nonpoint Source Task Force coordinates joint watershed management efforts with SCS, USFS, BLM. Intense grazing and...nonpoint source water pollution discharges from unimproved lands, particularly military lands. Increasing emphasis at national and state levels on...lands, particularly military lands. Increasing emphasis at national and state levels on controlling pollutant discharges from nonpoint sources and
Leland, W.T.
1960-01-01
The ion source described essentially eliminater the problem of deposits of nonconducting materials forming on parts of the ion source by certain corrosive gases. This problem is met by removing both filament and trap from the ion chamber, spacing them apart and outside the chamber end walls, placing a focusing cylinder about the filament tip to form a thin collimated electron stream, aligning the cylinder, slits in the walls, and trap so that the electron stream does not bombard any part in the source, and heating the trap, which is bombarded by electrons, to a temperature hotter than that in the ion chamber, so that the tendency to build up a deposit caused by electron bombardment is offset by the extra heating supplied only to the trap.
Constricted glow discharge plasma source
Anders, Andre; Anders, Simone; Dickinson, Michael; Rubin, Michael; Newman, Nathan
2000-01-01
A constricted glow discharge chamber and method are disclosed. The polarity and geometry of the constricted glow discharge plasma source is set so that the contamination and energy of the ions discharged from the source are minimized. The several sources can be mounted in parallel and in series to provide a sustained ultra low source of ions in a plasma with contamination below practical detection limits. The source is suitable for applying films of nitrides such as gallium nitride and oxides such as tungsten oxide and for enriching other substances in material surfaces such as oxygen and water vapor, which are difficult process as plasma in any known devices and methods. The source can also be used to assist the deposition of films such as metal films by providing low-energy ions such as argon ions.
Slit-lamp photography made easy by a spot metering system.
Khaw, P T; Elkington, A R
1988-01-01
The use of a standard 35 mm camera with a spot metering system to take slit-lamp photographs is described. This system is mounted on a standard Haag-Streit slit-lamp and can be used with good results even by inexperienced operators. Images PMID:3390424
Atmospheric sampling glow discharge ionization source
McLuckey, S.A.; Glish, G.L.
1989-07-18
An atmospheric sampling glow discharge ionization source that can be used in combination with an analytical instrument which operates at high vacuum, such as a mass spectrometer. The atmospheric sampling glow discharge ionization source comprises a chamber with at least one pair of electrodes disposed therein, an inlet for a gaseous sample to be analyzed and an outlet communicating with an analyzer which operates at subatmospheric pressure. The ionization chamber is maintained at a pressure below atmospheric pressure, and a voltage difference is applied across the electrodes to induce a glow discharge between the electrodes, so that molecules passing through the inlet are ionized by the glow discharge and directed into the analyzer. The ionization source accepts the sample under atmospheric pressure conditions and processes it directly into the high vacuum instrument, bridging the pressure gap and drawing off unwanted atmospheric gases. The invention also includes a method for analyzing a gaseous sample using the glow discharge ionization source described above. 3 figs.
The safety and efficacy of sublingual and oral immunotherapy for milk allergy.
Keet, Corinne A; Frischmeyer-Guerrerio, Pamela A; Thyagarajan, Ananth; Schroeder, John T; Hamilton, Robert G; Boden, Stephen; Steele, Pamela; Driggers, Sarah; Burks, A Wesley; Wood, Robert A
2012-02-01
Oral immunotherapy (OIT) and sublingual immunotherapy (SLIT) are potential therapies for food allergy, but the optimal method of administration, mechanism of action, and duration of response remain unknown. We sought to explore the safety and efficacy of OIT and SLIT for the treatment of cow's milk (CM) allergy. We randomized children with CM allergy to SLIT alone or SLIT followed by OIT. After screening double-blind, placebo-controlled food challenges and initial SLIT escalation, subjects either continued SLIT escalation to 7 mg daily or began OIT to either 1000 mg (the OITB group) or 2000 mg (the OITA group) of milk protein. They were challenged with 8 g of milk protein after 12 and 60 weeks of maintenance. If they passed the 60-week challenge, therapy was withdrawn, with challenges repeated 1 and 6 weeks later. Mechanistic correlates included end point titration skin prick testing and measurement of CM-specific IgE and IgG(4) levels, basophil histamine release, constitutive CD63 expression, CD203c expression, and intracellular spleen tyrosine kinase levels. Thirty subjects with CM allergy aged 6 to 17 years were enrolled. After therapy, 1 of 10 subjects in the SLIT group, 6 of 10 subjects in the SLIT/OITB group, and 8 of 10 subjects in the OITA group passed the 8-g challenge (P = .002, SLIT vs OIT). After avoidance, 6 of 15 subjects (3 of 6 subjects in the OITB group and 3 of 8 subjects in the OITA group) regained reactivity, 2 after only 1 week. Although the overall reaction rate was similar, systemic reactions were more common during OIT than during SLIT. By the end of therapy, titrated CM skin prick test results and CD63 and CD203c expression decreased and CM-specific IgG(4) levels increased in all groups, whereas CM-specific IgE and spontaneous histamine release values decreased in only the OIT group. OIT was more efficacious for desensitization to CM than SLIT alone but was accompanied by more systemic side effects. Clinical desensitization was lost in some cases within 1 week off therapy. Copyright © 2011 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.
Primary lacrimal canaliculitis - A clinical entity often misdiagnosed.
Singh, Manpreet; Gautam, Natasha; Agarwal, Aniruddha; Kaur, Manpreet
2018-03-01
Primary lacrimal canaliculitis (PLC) is a unique disorder which often gets misdiagnosed by the general as well as speciality-trained ophthalmologists. Elderly patients with history of chronic or recurrent epiphora with discharge, often get mislead towards chronic dacryocystitis. The aim of our report is to discuss the misleading diseases in our PLC patients and to revisit this hidden disease. The patients of PLC who were previously misdiagnosed were studied. The clinical history, presenting clinical features, misdiagnosis, and final management of the patients is described. There were 5 misdiagnosed female patients. A history of chronic redness, watering, discharge, and medial canthal region edema lead to the misdiagnosis of chronic dacryocystitis in 3 (60%) and medial marginal chalazion in 2 (40%) cases. Slit-lamp examination revealed localized hyperemia (n = 5), classical pouting of lacrimal punctum (n = 3), and expressible purulent discharge (n = 3). Two patients without punctum pouting had an explicit yellowish hue/discoloration of the canalicular region. Our patients had a mean 4 visits before an accurate diagnosis. Three-snip punctoplasty with canalicular curettage was performed in three while two were managed conservatively. At last follow-up, all patients were symptom-free with punctum and canalicular scarring in three, who underwent surgery. PLC is a frequently misdiagnosed clinical entity which delays the initiation of appropriate treatment. A succinct magnified examination of punctum and canalicular region can provide sufficient clues pivotal for accurate diagnosis.
Code of Federal Regulations, 2010 CFR
2010-07-01
... subcategory of direct discharge point sources that do not use end-of-pipe biological treatment. 414.100... AND STANDARDS ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS Direct Discharge Point Sources That Do Not Use End-of-Pipe Biological Treatment § 414.100 Applicability; description of the subcategory of...
Corona discharges from a windmill and its lightning protection tower in winter thunderstorms
NASA Astrophysics Data System (ADS)
Wu, Ting; Wang, Daohong; Rison, William; Thomas, Ronald J.; Edens, Harald E.; Takagi, Nobuyuki; Krehbiel, Paul R.
2017-05-01
This paper presents lightning mapping array (LMA) observations of corona discharges from a windmill and its lightning protection tower in winter thunderstorms in Japan. Corona discharges from the windmill, called windmill coronas, and those from the tower, called tower coronas, are distinctly different. Windmill coronas occur with periodic bursts, generally radiate larger power, and possibly develop to higher altitudes than tower coronas do. A strong negative electric field is necessary for the frequent production of tower coronas but is not apparently related with windmill coronas. These differences are due to the periodic rotation of the windmill and the moving blades which can escape space charges produced by corona discharges and sustain a large local electric field. The production period of windmill coronas is related with the rotation period of the windmill. Surprisingly, for one rotation of the windmill, only two out of the three blades produce detectable discharges and source powers of discharges from these two blades are different. The reason for this phenomenon is still unclear. For tower coronas, the source rate can get very high only when there is a strong negative electric field, and the source power can get very high only when the source rate is very low. The relationship between corona discharges and lightning flashes is investigated. There is no direct evidence that corona discharges can increase the chance of upward leader initiation, but nearby lightning flashes can increase the source rate of corona discharges right after the flashes. The peak of the source height distribution of corona discharges is about 100 m higher than the top of the windmill and the top of the tower. Possible reasons for this result are discussed.
Extraction electrode geometry for a calutron
Veach, A.M.; Bell, W.A. Jr.
1975-09-23
This patent relates to an improved geometry for the extraction electrode and the ground electrode utilized in the operation of a calutron. The improved electrodes are constructed in a partial-picture-frame fashion with the slits of both electrodes formed by two tungsten elongated rods. Additional parallel spaced-apart rods in each electrode are used to establish equipotential surfaces over the rest of the front of the ion source. (auth)
NASA Technical Reports Server (NTRS)
Paciotti, Gabriel; Humphries, Martin; Rottmeier, Fabrice; Blecha, Luc
2014-01-01
In the frame of ESA's Solar Orbiter scientific mission, Almatech has been selected to design, develop and test the Slit Change Mechanism of the SPICE (SPectral Imaging of the Coronal Environment) instrument. In order to guaranty optical cleanliness level while fulfilling stringent positioning accuracies and repeatability requirements for slit positioning in the optical path of the instrument, a linear guiding system based on a double flexible blade arrangement has been selected. The four different slits to be used for the SPICE instrument resulted in a total stroke of 16.5 mm in this linear slit changer arrangement. The combination of long stroke and high precision positioning requirements has been identified as the main design challenge to be validated through breadboard models testing. This paper presents the development of SPICE's Slit Change Mechanism (SCM) and the two-step validation tests successfully performed on breadboard models of its flexible blade support system. The validation test results have demonstrated the full adequacy of the flexible blade guiding system implemented in SPICE's Slit Change Mechanism in a stand-alone configuration. Further breadboard test results, studying the influence of the compliant connection to the SCM linear actuator on an enhanced flexible guiding system design have shown significant enhancements in the positioning accuracy and repeatability of the selected flexible guiding system. Preliminary evaluation of the linear actuator design, including a detailed tolerance analyses, has shown the suitability of this satellite roller screw based mechanism for the actuation of the tested flexible guiding system and compliant connection. The presented development and preliminary testing of the high-precision long-stroke Slit Change Mechanism for the SPICE Instrument are considered fully successful such that future tests considering the full Slit Change Mechanism can be performed, with the gained confidence, directly on a Qualification Model. The selected linear Slit Change Mechanism design concept, consisting of a flexible guiding system driven by a hermetically sealed linear drive mechanism, is considered validated for the specific application of the SPICE instrument, with great potential for other special applications where contamination and high precision positioning are dominant design drivers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Xiangjun; Yao, Qisheng, E-mail: yymcyqs@126.com; Sun, Xinbo
Hypoxic acute kidney injury (AKI) is often incompletely repaired and leads to chronic kidney disease (CKD), which is characterized by tubulointerstitial inflammation and fibrosis. The Slit2 family of secreted glycoproteins is expressed in the kidney, it has been shown to exert an anti-inflammatory activity and prevent ischemic renal injury in vivo. However, whether Slit2 reduces renal fibrosis and inflammation after hypoxic and inflammatory epithelial cells injury in vitro remains unknown. In this study, we aimed to evaluate whether Slit2 ameliorated fibrosis and inflammation in two renal epithelial cells line challenged with hypoxia and lipopolysaccharide (LPS). Renal epithelial cells were treatedmore » with hypoxia and LPS to induce cell injury. Hoechst staining and Western blot analysis was conducted to examine epithelial cells injury. Immunofluorescence staining and Western blot analysis was performed to evaluate tubulointerstitial fibrosis. Real-time polymerase chain reaction (PCR) tested the inflammatory factor interleukin (IL)−1β and tumor necrosis factor (TNF)-α, and Western blot analysis determined the hypoxia-inducible factor (HIF)−1α, Toll-like receptor 4 (TLR4) and nuclear factor (NF)-κB. Results revealed that hypoxia induced epithelial cells apoptosis, inflammatory factor IL-1β and TNF-α release and tubulointerstitial fibrosis. LPS could exacerbate hypoxia -induced epithelial cells apoptosis, IL-1β and TNF-α release and fibrosis. Slit2 reduced the expression of fibronectin, the rate of epithelial cell apoptosis, and the expression of inflammatory factor. Slit2 could also inhibit the expression of TLR4 and NF-κB, but not the expression of HIF-1α. Therefore, Slit2 attenuated inflammation and fibrosis after LPS- and hypoxia-induced epithelial cells injury via the TLR4/NF-κB signaling pathway, but not depending on the HIF-1α signaling pathway. - Highlights: • Slit2 ameliorates inflammation after hypoxia-and LPS-induced epithelial cells injury. • Slit2 ameliorates fibrosis after hypoxia-and LPS-induced epithelial cells injury. • Slit2 ameliorates inflammation and fibrosis after hypoxia-and LPS-induced renal epithelial cells injury via TLR4/NF-κB.« less
Gellrich, Marcus-Matthias
2015-01-01
Fundus biomicroscopy with the slit lamp as it is practiced widely nowadays was not established until the 1980-es with the introduction of the Volk lenses +90 and +60D. Thereafter little progress has been made in retinal imaging with the slit lamp. It is the aim of this paper to fully exploit the potential of a video slit lamp for fundus documentation by using easily accessible additions. Suitable still images are easily retrieved from videorecordings of slit lamp examinations. The effects of changements in the slit lamp itself (slit beam and apertures) and its examination equipment (converging lenses from +40 to +90D) on quality and spectrum of fundus images are demonstrated. Imaging software is applied for reconstruction of larger fundus areas in a mosaic pattern (Hugin®) and to perform the flicker test in order to visualize changes in the same fundus area at different points of time (Power Point®). The three lenses +90/+60/+40D are a good choice for imaging the whole spectrum of retinal diseases. Displacement of the oblique slit light can be used to assess changes in the surface profile of the inner retina which occurs e.g. in macular holes or pigment epithelial detachment. The mosaic function in its easiest form (one strip macula adapted to one strip with the optic disc) provides an overview of the posterior pole comparable to a fundus camera's image. A reconstruction of larger fundus areas is feasible for imaging in vitreoretinal surgery or occlusive vessel disease. The flicker test is a fine tool for monitoring progressive glaucoma by changes in the optic disc, and it is also a valuable diagnostic tool in macular disease. Nearly all retinal diseases can be imaged with the slit lamp - irrespective whether they affect the posterior pole, mainly the optic nerve or the macula, the whole retina or only its periphery. Even a basic fundus controlled perimetry is possible. Therefore fundus videography with the slit lamp is a worthwhile approach especially for the many ophthalmologists without access to the most recent diagnostic equipment or a professional photographer at hand.
NASA Astrophysics Data System (ADS)
de Barros, Felipe P. J.
2018-07-01
Quantifying the uncertainty in solute mass discharge at an environmentally sensitive location is key to assess the risks due to groundwater contamination. Solute mass fluxes are strongly affected by the spatial variability of hydrogeological properties as well as release conditions at the source zone. This paper provides a methodological framework to investigate the interaction between the ubiquitous heterogeneity of the hydraulic conductivity and the mass release rate at the source zone on the uncertainty of mass discharge. Through the use of perturbation theory, we derive analytical and semi-analytical expressions for the statistics of the solute mass discharge at a control plane in a three-dimensional aquifer while accounting for the solute mass release rates at the source. The derived solutions are limited to aquifers displaying low-to-mild heterogeneity. Results illustrate the significance of the source zone mass release rate in controlling the mass discharge uncertainty. The relative importance of the mass release rate on the mean solute discharge depends on the distance between the source and the control plane. On the other hand, we find that the solute release rate at the source zone has a strong impact on the variance of the mass discharge. Within a risk context, we also compute the peak mean discharge as a function of the parameters governing the spatial heterogeneity of the hydraulic conductivity field and mass release rates at the source zone. The proposed physically-based framework is application-oriented, computationally efficient and capable of propagating uncertainty from different parameters onto risk metrics. Furthermore, it can be used for preliminary screening purposes to guide site managers to perform system-level sensitivity analysis and better allocate resources.
Crank angle detecting system for engines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yuzawa, H.; Nishiyama, M.; Nakamura, K.
1988-05-31
An ignition system for a multi-cylinder internal combustion engine is described comprising: (a) engine cylinders in which spark plugs are installed respectively, (b) indicating means disposed so as to synchronize with an engine crankshaft and formed with a large number of slits and a small number of slits, the large number of slits being provided for indicating crankshaft angular positions and the small number of slits being provided for indicating predetermined piston strokes and wherein the small number of slits have mutually different widths from each other to distinguish between piston strokes of at least the groups of cylinders; (c)more » sensing means for sensing crankshaft angular positions in cooperation with the large number of slits of the indicating means and outputting a crank angle signal representing the crankshaft angular position and for sensing the predetermined piston strokes in cooperation with the small number of slits and outputting different width piston stroke signals corresponding to the different width slits; (d) discriminating means for identifying each cylinder group and outputting cylinder group identification signals on the basis of the different width stroke signals derived from the sensing means; (e) ignition timing determining means for generating an ignition timing signal on the basis of the crank angle signal; (f) ignition coil controlling means for generating ignition coil current signals corresponding to the cylinder group identification signals; and (g) ignition timing controlling means for generating cylinder group ignition signals in response to the ignition coil current signals and ignition timing signal so that the spark plugs of each cylinder group are ignited at a proper time.« less
Cold and intense OH radical beam sources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ploenes, Ludger; Meerakker, Sebastiaan Y. T. van de; Haas, Dominik
2016-05-15
We present the design and performance of two supersonic radical beam sources: a conventional pinhole-discharge source and a dielectric barrier discharge (DBD) source, both based on the Nijmegen pulsed valve. Both designs have been characterized by discharging water molecules seeded in the rare gases Ar, Kr, or Xe. The resulting OH radicals have been detected by laser-induced fluorescence. The measured OH densities are (3.0 ± 0.6) × 10{sup 11} cm{sup -3} and (1.0 ± 0.5) × 10{sup 11} cm{sup -3} for the pinhole-discharge and DBD sources, respectively. The beam profiles for both radical sources show a relative longitudinal velocity spreadmore » of about 10%. The absolute rotational ground state population of the OH beam generated from the pinhole-discharge source has been determined to be more than 98%. The DBD source even produces a rotationally colder OH beam with a population of the ground state exceeding 99%. For the DBD source, addition of O{sub 2} molecules to the gas mixture increases the OH beam density by a factor of about 2.5, improves the DBD valve stability, and allows to tune the mean velocity of the radical beam.« less
Oliva, Carlos; Soldano, Alessia; Mora, Natalia; De Geest, Natalie; Claeys, Annelies; Erfurth, Maria-Luise; Sierralta, Jimena; Ramaekers, Ariane; Dascenco, Dan; Ejsmont, Radoslaw K; Schmucker, Dietmar; Sanchez-Soriano, Natalia; Hassan, Bassem A
2016-10-24
The axonal wiring molecule Slit and its Round-About (Robo) receptors are conserved regulators of nerve cord patterning. Robo receptors also contribute to wiring brain circuits. Whether molecular mechanisms regulating these signals are modified to fit more complex brain wiring processes is unclear. We investigated the role of Slit and Robo receptors in wiring Drosophila higher-order brain circuits and identified differences in the cellular and molecular mechanisms of Robo/Slit function. First, we find that signaling by Robo receptors in the brain is regulated by the Receptor Protein Tyrosine Phosphatase RPTP69d. RPTP69d increases membrane availability of Robo3 without affecting its phosphorylation state. Second, we detect no midline localization of Slit during brain development. Instead, Slit is enriched in the mushroom body, a neuronal structure covering large areas of the brain. Thus, a divergent molecular mechanism regulates neuronal circuit wiring in the Drosophila brain, partly in response to signals from the mushroom body. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Slits Affect the Timely Migration of Neural Crest Cells via Robo Receptor
Giovannone, Dion; Reyes, Michelle; Reyes, Rachel; Correa, Lisa; Martinez, Darwin; Ra, Hannah; Gomez, Gustavo; Kaiser, Josh; Ma, Le; Stein, Mary-Pat; de Bellard, Maria Elena
2013-01-01
SUMMARY Background Neural crest cells emerge by delamination from the dorsal neural tube and give rise to various components of the peripheral nervous system in vertebrate embryos. These cells change from non-motile into highly motile cells migrating to distant areas before further differentiation. Mechanisms controlling delamination and subsequent migration of neural crest cells are not fully understood. Slit2, a chemorepellant for axonal guidance that repels and stimulates motility of trunk neural crest cells away from the gut has recently been suggested to be a tumor suppressor molecule. The goal of this study was to further investigate the role of Slit2 in trunk neural crest cell migration by constitutive expression in neural crest cells. Results We found that Slit gain-of-function significantly impaired neural crest cell migration while Slit loss-of-function favored migration. In addition, we observed that the distribution of key cytoskeletal markers was disrupted in both gain and loss of function instances. Conclusions These findings suggest that Slit molecules might be involved in the processes that allow neural crest cells to begin migration and transitioning to a mesenchymal type. PMID:22689303
NASA Astrophysics Data System (ADS)
Ferdous, Md. Shafiul; Setyabudi, Sofyan Arief; Makabe, Chobin; Fujikawa, Masaki
2013-05-01
The fatigue and fracture behavior of C/C composites fabricated using fine-woven carbon fiber laminates with α = 0/90° direction were investigated. Also, the phenomenon of crack growth behavior and the shear damage in the fiber bundle was discussed. Slits of several sizes were cut on both sides of a test section and different sizes of slit length were chosen. The effect of the slit configuration on crack initiation and growth behavior was observed. Specimens with blunt-notches and center-holes were also used to compare the fatigue strength and crack growth behavior. Non-propagating cracks were observed and fatigue limit was defined as the maximum stress at which specimen did not break for N = 107 cycles stress application. The longest fatigue life was obtained in the case of specimens with shorter slits. The relationships between fatigue strengths and specimen shapes were analyzed by stress concentration, Kt, and stress intensity factor, KI. The effect of slit configuration on fatigue strength was then discussed regarding both the experimental and calculated consequences.
Frischmeyer-Guerrerio, Pamela A.; Keet, Corinne A.; Guerrerio, Anthony L.; Chichester, Kristin L.; Bieneman, Anja P.; Hamilton, Robert G.; Wood, Robert A.; Schroeder, John T.
2014-01-01
Sublingual (SLIT) and oral immunotherapy (OIT) are promising treatments for food allergy, but underlying mechanisms are poorly understood. Dendritic cells (DC) induce and maintain Th2-type allergen-specific T cells, and also regulate innate immunity through their expression of Toll-like receptors (TLRs). We examined how SLIT and OIT influenced DC innate and adaptive immune responses in children with IgE-mediated cow's milk (CM) allergy. SLIT, but not OIT, decreased TLR-induced IL-6 secretion by myeloid DCs (mDCs). SLIT and OIT altered mDC IL-10 secretion, a potent inhibitor of FcεRI-dependent pro-inflammatory responses. OIT uniquely augmented IFN-α and decreased IL-6 secretion by plasmacytoid DCs (pDCs), which was associated with reduced TLR-induced IL-13 release in pDC-T cell co-cultures. Both SLIT and OIT decreased Th2 cytokine secretion to CM in pDC-T, but not mDC-T, co-cultures. Therefore, SLIT and OIT exert unique effects on DC-driven innate and adaptive immune responses, which may inhibit allergic inflammation and promote tolerance. PMID:25173802
Multilayer hexagonal silicon forming in slit nanopore
He, Yezeng; Li, Hui; Sui, Yanwei; Qi, Jiqiu; Wang, Yanqing; Chen, Zheng; Dong, Jichen; Li, Xiongying
2015-01-01
The solidification of two-dimensional liquid silicon confined to a slit nanopore has been studied using molecular dynamics simulations. The results clearly show that the system undergoes an obvious transition from liquid to multilayer hexagonal film with the decrease of temperature, accompanied by dramatic change in potential energy, atomic volume, coordination number and lateral radial distribution function. During the cooling process, some hexagonal islands randomly appear in the liquid first, then grow up to grain nuclei, and finally connect together to form a complete polycrystalline film. Moreover, it is found that the quenching rate and slit size are of vital importance to the freezing structure of silicon film. The results also indicate that the slit nanopore induces the layering of liquid silicon, which further induces the slit size dependent solidification behavior of silicon film with different electrical properties. PMID:26435518
IRMS: Infrared Multi-Slit Spectrograph for TMT
NASA Astrophysics Data System (ADS)
U, Vivian; Mobasher, B.
2014-07-01
As one of the first-light instruments on the TMT, the IRMS is a near-infrared multi-slit spectrograph and imager designed to sample near the diffraction limit with the help of adaptive optics. Fed by the Narrow-Field Infrared Adaptive Optics Systems (NFIRAOS) on the TMT, the IRMS will provide near-infrared imaging and multi-object spectroscopy at Y, J, H, and K bands (0.9-2.5 microns) with moderate spectral resolution. With a field of view of ~2 arcmin on a side, it has a multiplex capability of up to 46 slits using a slit mask system on a cryogenic configurable slit unit. Here we present a preliminary version of the exposure time calculator for sensitivity comparison with Keck/MOSFIRE. Selected science cases are highlighted to demonstrate the need for IRMS in this upcoming thirty-meter class telescope era.
Functional metasurfaces based on metallic and dielectric subwavelength slits and stripes array
NASA Astrophysics Data System (ADS)
Guo, Yinghui; Pu, Mingbo; Li, Xiong; Ma, Xiaoliang; Gao, Ping; Wang, Yanqin; Luo, Xiangang
2018-04-01
Starting with the early works of extraordinary optical transmission and extraordinary Young’s interference, researchers have been fascinated by the unusual optical properties displayed by metallic holes/slits and subsequently found similar abnormities in dielectric counterparts. Benefiting from the shrinking wavelength of surface plasmon polaritons excited in metallic slits and high refractive index of dielectric stripes, one can realize local phase modulation and approach desired dispersion by engineering the geometries of a slits and stripes array. In this review, we review recent developments in functional metasurfaces composed of various metallic and dielectric subwavelength slits and stripes arrays, with special emphasis on achromatic, ultra-broadband, quasi-continuous, multifunctional and reconfigurable metasurfaces. Particular attention is paid to provide insight into the design strategies for these devices. Finally, we give an outlook of the development in this fascinating area.
High field pulsed microwiggler comprising a conductive tube with periodically space slots
Warren, R.W.
1992-09-01
A microwiggler assembly produces large magnetic fields for oscillating charged particle beams, particularly electron beams for free electron laser (FEL) application. A tube of electrically conductive material is formed with radial slots axially spaced at the period of the electron beam. The slots have alternate 180[degree] relationships and are formed to a maximum depth of 0.6 to 0.7 times the tube circumference. An optimum slot depth is selected to eliminate magnetic quadrupole fields within the microwiggler as determined from a conventional pulsed wire technique. Suitable slot configurations include single slits, double slits, triple slits, and elliptical slots. An axial electron beam direction is maintained by experimentally placing end slits adjacent entrance and exit portions of the assembly, where the end slit depth is determined by use of the pulsed wire technique outside the tube. 10 figs.
High field pulsed microwiggler comprising a conductive tube with periodically space slots
Warren, Roger W.
1992-01-01
A microwiggler assembly produces large magnetic fields for oscillating ched particle beams, particularly electron beams for free electron laser (FEL) application. A tube of electrically conductive material is formed with radial slots axially spaced at the period of the electron beam. The slots have alternate 180.degree. relationships and are formed to a maximum depth of 0.6 to 0.7 times the tube circumference. An optimum slot depth is selected to eliminate magnetic quadrupole fields within the microwiggler as determined from a conventional pulsed wire technique. Suitable slot configurations include single slits, double slits, triple slits, and elliptical slots. An axial electron beam direction is maintained by experimentally placing end slits adjacent entrance and exit portions of the assembly, where the end slit depth is determined by use of the pulsed wire technique outside the tube.
NASA Astrophysics Data System (ADS)
Williams, Darius; Marshall, Jennifer L.; Schmidt, Luke M.; Prochaska, Travis; DePoy, Darren L.
2018-01-01
The Giant Magellan Telescope Multi-object Astronomical and Cosmological Spectrograph (GMACS) is currently in development for the Giant Magellan Telescope (GMT). GMACS will employ slit masks with a usable diameter of approximately 0.450 m for the purpose of multi-slit spectroscopy. Of significant importance are the design constraints and parameters of the multi-object slit masks themselves as well as the means for mapping astronomical targets to physical mask locations. Analytical methods are utilized to quantify deformation effects on a potential slit mask due to thermal expansion and vignetting of target light cones. Finite element analysis (FEA) is utilized to simulate mask flexure in changing gravity vectors. The alpha version of the mask creation program for GMACS, GMACS Mask Simulator (GMS), a derivative of the OSMOS Mask Simulator (OMS), is introduced.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xie Yahong; Hu Chundong; Liu Sheng
2012-01-15
Arc discharge of a hot cathode bucket ion source tends to be unstable what attributes to the filament self-heating and energetic electrons backstreaming from the accelerator. A regulation method, which based on the ion density measurement by a Langmuir probe, is employed for stable arc discharge operation and long pulse ion beam generation. Long pulse arc discharge of 100 s is obtained based on this regulation method of arc power. It establishes a foundation for the long pulse arc discharge of a megawatt ion source, which will be utilized a high power neutral beam injection device.
Xie, Yahong; Hu, Chundong; Liu, Sheng; Jiang, Caichao; Li, Jun; Liang, Lizhen
2012-01-01
Arc discharge of a hot cathode bucket ion source tends to be unstable what attributes to the filament self-heating and energetic electrons backstreaming from the accelerator. A regulation method, which based on the ion density measurement by a Langmuir probe, is employed for stable arc discharge operation and long pulse ion beam generation. Long pulse arc discharge of 100 s is obtained based on this regulation method of arc power. It establishes a foundation for the long pulse arc discharge of a megawatt ion source, which will be utilized a high power neutral beam injection device.
Meng, Qingxiang; Liu, Xiaolong; Li, Peng; He, Long; Xie, Jinghua; Gao, Xionghui; Wu, Xiaozhong; Su, Fang; Liang, Yong
2016-08-01
This study aimed to investigate the clinical efficacy of sublingual immunotherapy (SLIT) with house dust mite (HDM) extract and to examine T helper 2 (Th2)-type immune responses mediated by the thymic stromal lymphopoietin (TSLP-OX40L) signaling pathway in patients with moderate to severe allergic rhinitis (AR) after 12-month HDM SLIT. Forty-six cases of HDM-sensitized patients with persistent AR in southern China were enrolled in this study. Clinical efficacy of SLIT was assessed by determining the individual nasal symptom score (INSS) and total nasal symptom score (TNSS) after 12-month HDM SLIT. Moreover, the TSLP-OX40L signaling pathway was investigated through measurements of TSLP by enzyme-labeled immunosorbent assay (ELISA) and OX40L by quantitative reverse transcription polymerase chain reaction (qRT-PCR) and flow cytometry. After 12 months of HDM SLIT, TNSS and INSS were significantly decreased overall compared with baseline values (p < 0.001). By the end of the 12-month HDM SLIT, TNSS had declined by ∼50% compared with baseline, and the corresponding level of TSLP in nasal lavage decreased significantly (p < 0.05). The level of OX40L messenger RNA (mRNA) in blood was markedly decreased significantly after 12-month HDM SLIT compared with baseline (t = 12.300, p < 0.05). Furthermore, significant decreases in OX40L expression on the surface of peripheral blood mononuclear cells (PBMCs) (t = 13.100, p < 0.05) and OX40L expression on the surface of CD11c+CD86+ cells in PBMCs (t = 9.946, p < 0.05) after 12-month HDM SLIT were observed. HDM SLIT downregulated Th2-type immune responses mediated by the TSLP-OX40L signaling pathway in patients with persistent moderate to severe AR. © 2016 ARS-AAOA, LLC.
Code of Federal Regulations, 2010 CFR
2010-07-01
... ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS Direct Discharge Point Sources That Use End-of-Pipe... subcategory of direct discharge point sources that use end-of-pipe biological treatment. 414.90 Section 414.90... that use end-of-pipe biological treatment. The provisions of this subpart are applicable to the process...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 29 2010-07-01 2010-07-01 false BAT and NSPS Effluent Limitations for Priority Pollutants for Direct Discharge Point Sources That use End-of-Pipe Biological Treatment 4 Table 4... Limitations for Priority Pollutants for Direct Discharge Point Sources That use End-of-Pipe Biological...
DOE Office of Scientific and Technical Information (OSTI.GOV)
M Severson; M Bissen; M Fisher
SRC has recently commissioned a new Varied Line-Spacing Plane Grating Monochromator (VLS-PGM) utilizing as its source a 1 m long APPLE II insertion device in short-straight-section 9 of the Aladdin storage ring. The insertion device reliably delivers horizontal, vertical, and right and left circularly polarized light to the beamline. Measurements from an in situ polarimeter can be used for undulator corrections to compensate for depolarizing effects of the beamline. The beamline has only three optical elements and covers the energy range from 11.1 to 270 eV using two varied line-spacing gratings. A plane mirror rotates to illuminate the gratings atmore » the correct angle to cancel the defocus term at all photon energies. An exit slit and elliptical-toroid refocusing mirror complete the beamline. Using a 50 {mu}m exit slit, the beamline provides moderate to high resolution, with measured flux in the mid 10{sup 12} (photons/s/200 mA) range, and a spot size of 400 {mu}m horizontal by 30 {mu}m vertical.« less
Development of intense terahertz coherent synchrotron radiation at KU-FEL
NASA Astrophysics Data System (ADS)
Sei, Norihiro; Zen, Heishun; Ohgaki, Hideaki
2016-10-01
We produced intense coherent synchrotron radiation (CSR) in the terahertz (THz) region using an S-band linac at the Kyoto University Free Electron Laser (KU-FEL), which is a mid-infrared free-electron laser facility. The CSR beam was emitted from short-pulse electron bunches compressed by a 180° arc, and was transferred to air at a large solid angle of 0.10 rad. The measured CSR energy was 55 μJ per 7 μs macropulse, and KU-FEL was one of the most powerful CSR sources in normal conducting linear accelerator facilities. The CSR spectra were measured using an uncooled pyroelectric detector and a Michelson-type interferometer designed specifically for the KU-FEL electron beam, and had a maximum at a frequency of 0.11 THz. We found that adjusting the energy slit enhanced the CSR energy and shortened the electron beam bunch length in the CSR spectra measurements. Our results demonstrated that the efficient use of the energy slit can help improve the characteristics of CSR.
Development of a new linearly variable edge filter (LVEF)-based compact slit-less mini-spectrometer
NASA Astrophysics Data System (ADS)
Mahmoud, Khaled; Park, Seongchong; Lee, Dong-Hoon
2018-02-01
This paper presents the development of a compact charge-coupled detector (CCD) spectrometer. We describe the design, concept and characterization of VNIR linear variable edge filter (LVEF)- based mini-spectrometer. The new instrument has been realized for operation in the 300 nm to 850 nm wavelength range. The instrument consists of a linear variable edge filter in front of CCD array. Low-size, light-weight and low-cost could be achieved using the linearly variable filters with no need to use any moving parts for wavelength selection as in the case of commercial spectrometers available in the market. This overview discusses the main components characteristics, the main concept with the main advantages and limitations reported. Experimental characteristics of the LVEFs are described. The mathematical approach to get the position-dependent slit function of the presented prototype spectrometer and its numerical de-convolution solution for a spectrum reconstruction is described. The performance of our prototype instrument is demonstrated by measuring the spectrum of a reference light source.
Ion optical design of a collinear laser-negative ion beam apparatus.
Diehl, C; Wendt, K; Lindahl, A O; Andersson, P; Hanstorp, D
2011-05-01
An apparatus for photodetachment studies on atomic and molecular negative ions of medium up to heavy mass (M ≃ 500) has been designed and constructed. Laser and ion beams are merged in the apparatus in a collinear geometry and atoms, neutral molecules and negative ions are detected in the forward direction. The ion optical design and the components used to optimize the mass resolution and the transmission through the extended field-free interaction region are described. A 90° sector field magnet with 50 cm bending radius in combination with two slits is used for mass dispersion providing a resolution of M∕ΔM≅800 for molecular ions and M∕ΔM≅400 for atomic ions. The difference in mass resolution for atomic and molecular ions is attributed to different energy distributions of the sputtered ions. With 1 mm slits, transmission from the source through the interaction region to the final ion detector was determined to be about 0.14%.
Sedaghat, Mohammad Reza; Daneshvar, Ramin; Kargozar, Abbas; Derakhshan, Akbar; Daraei, Mona
2010-12-01
To evaluate and compare central corneal thickness measurements using rotating Scheimpflug camera, scanning-slit topography, and ultrasound pachymetry in virgin, healthy corneas. Prospective, observational, cross-sectional study. Central corneal thickness in 157 healthy eyes of 157 patients without ocular abnormalities other than refractive errors was measured, in a sequential order, once with rotating Scheimpflug camera and scanning-slit topography and 3 times with ultrasound pachymetry as the last part of examination. All measurements were performed by a single experienced examiner. The results from scanning-slit topography are given with and without correction for "acoustic correction factor" of 0.92. The average measurements of central corneal thickness by rotating Scheimpflug imaging, scanning-slit pachymetry, and ultrasound were 537.15 ± 32.98 μm, 542.06 ± 39.04 μm, and 544.07 ± 34.75 μm, respectively. The mean differences between modalities were 6.92 μm between rotating Scheimpflug and ultrasound (P < .0001), 2.01 μm between corrected scanning-slit and ultrasound (P = .204), and 4.91 μm between corrected scanning-slit and rotating Scheimpflug imaging (P = .001). According to Bland-Altman analysis, highest agreement was between ultrasonic and rotating Scheimpflug pachymetry. In the assessment of normal corneas, rotating Scheimpflug topography measures central corneal thickness values with higher agreement to ultrasound pachymetry. Copyright © 2010 Elsevier Inc. All rights reserved.
Lin, Zhibin; Zhou, Lifeng; Luo, Xi; Xia, Wentong; Chen, Dehua; Xu, Rui; Wang, Jie; Luo, Renzhong; Xu, Geng; Li, Huabin
2013-08-01
To evaluate the clinical efficacy of sublingual immunotherapy (SLIT) with house-dust mite (HDM) extract and to examine the change of biomarkers (TIM-1, IL-5 and IL-10) after 6-month SLIT in children with allergic rhinitis (AR). One hundred and sixteen HDM-sensitized children with persistent AR were enrolled to assess the clinical efficacy of SLIT by determining the individual nasal symptom score (INSS) and total nasal symptom scores (TNSS) after 6-month SLIT. Moreover, the mRNA expression of TIM-1, IL-5 and IL-10 in peripheral blood mononuclear cells (PBMCs) was examined in 16 well-controlled and 12 uncontrolled AR patients using quantitative reverse transcription polymerase chain reaction (qRT-PCR). After 6-month SLIT, both TNSS and INSS scores were significantly decreased compared with the baseline value (p < 0.01). The rates for well-controlled, partly controlled and uncontrolled children were 43.1%, 32.8% and 24.1%, respectively. Accordingly, the mRNA levels of TIM-1 and IL-5 decreased significantly and IL-10 mRNA level increased significantly compared with the baseline value in well-controlled children (p < 0.05). Our findings suggest SLIT with HDM extract is effective and safe for AR children and TIM-1 may be considered as an indicator for evaluating the clinical efficacy of SLIT. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Zhang, Ya-Nan; Zhu, Xiu-Yun; Fang, Li-Ping; He, Peng; Wang, Zhi-Qiang; Chen, Geng; Sun, Liang; Ye, Zhan-Feng; Deng, Dao-Gui; Li, Jin-Bu
2015-01-01
Although the general pathway of sex pheromone synthesis in moth species has been established, the molecular mechanisms remain poorly understood. The common cutworm Spodoptera litura is an important agricultural pest worldwide and causes huge economic losses annually. The female sex pheromone of S. litura comprises Z9,E11-14:OAc, Z9,E12-14:OAc, Z9-14:OAc, and E11-14:OAc. By sequencing and analyzing the transcriptomic data of the sex pheromone glands, we identified 94 candidate genes related to pheromone biosynthesis (55 genes) or chemoreception (39 genes). Gene expression patterns and phylogenetic analysis revealed that two desaturase genes (SlitDes5 and SlitDes11) and one fatty acyl reductase gene (SlitFAR3) showed pheromone gland (PG) biased or specific expression, and clustered with genes known to be involved in pheromone synthesis in other moth species. Furthermore, 4 chemoreception related genes (SlitOBP6, SlitOBP11, SlitCSP3, and SlitCSP14) also showed higher expression in the PG, and could be additional candidate genes involved in sex pheromone transport. This study provides the first solid background information that should facilitate further elucidation of sex pheromone biosynthesis and transport, and indicates potential targets to disrupt sexual communication in S. litura for a novel pest management strategy. PMID:26445454
NASA Astrophysics Data System (ADS)
Dostanko, A. P.; Golosov, D. A.
2009-10-01
The possibility of using a plasma electron source (PES) with a discharge in crossed E × H field for compensating the ion beam from an end-Hall ion source (EHIS) is analyzed. The PES used as a neutralizer is mounted in the immediate vicinity of the EHIS ion generation and acceleration region at 90° to the source axis. The behavior of the discharge and emission parameters of the EHIS is determined for operation with a filament neutralizer and a plasma electron source. It is found that the maximal discharge current from the ion source attains a value of 3.8 A for operation with a PES and 4 A for operation with a filament compensator. It is established that the maximal discharge current for the ion source strongly depends on the working gas flow rate for low flow rates (up to 10 ml/min) in the EHIS; for higher flow rates, the maximum discharge current in the EHIS depends only on the emissivity of the PES. Analysis of the emission parameters of EHISs with filament and plasma neutralizers shows that the ion beam current and the ion current density distribution profile are independent of the type of the electron source and the ion current density can be as high as 0.2 mA/cm2 at a distance of 25 cm from the EHIS anode. The balance of currents in the ion source-electron source system is considered on the basis of analysis of operation of EHISs with various sources of electrons. It is concluded that the neutralization current required for operation of an ion source in the discharge compensation mode must be equal to or larger than the discharge current of the ion source. The use of PES for compensating the ion beam from an end-Hall ion source proved to be effective in processes of ion-assisted deposition of thin films using reactive gases like O2 or N2. The application of the PES technique makes it possible to increase the lifetime of the ion-assisted deposition system by an order of magnitude (the lifetime with a Ti cathode is at least 60 h and is limited by the replacement life of the deposited cathode insertion).
NASA Astrophysics Data System (ADS)
Brusseau, M. L.; Carroll, K. C.; Baker, J. B.; Allen, T.; DiGuiseppi, W.; Hatton, J.; Morrison, C.; Russo, A. E.; Berkompas, J. L.
2011-12-01
A large-scale permanganate-based in-situ chemical oxidation (ISCO) effort has been conducted over the past ten years at a federal Superfund site in Tucson, AZ, for which trichloroethene (TCE) is the primary contaminant of concern. Remediation performance was assessed by examining the impact of treatment on contaminant mass discharge, an approach that has been used for only a very few prior ISCO projects. Contaminant mass discharge tests were conducted before and after permanganate injection to measure the impact at the source-zone scale. The results indicate that ISCO caused a significant reduction in mass discharge (approximately 75%). The standard approach of characterizing discharge at the source-zone scale was supplemented with additional characterization at the plume scale, which was evaluated by examining the change in contaminant mass discharge associated with the pump-and-treat system. The integrated contaminant mass discharge decreased by approximately 70%, consistent with the source-zone-scale measurements. The integrated mass discharge rebounded from 0.1 to 0.2 Kg/d within one year after cessation of permanganate injections, after which it has been stable for several years. Collection of the integrated contaminant mass discharge data throughout the ISCO treatment period provided a high-resolution, real-time analysis of the site-wide impact of ISCO, thereby linking source-zone remediation to impacts on overall risk. The results indicate that ISCO was successful in reducing contaminant mass discharge at this site, which comprises a highly heterogeneous subsurface environment. Analysis of TCE sediment concentration data for core material collected before and after ISCO supports the hypothesis that the remaining mass discharge is associated in part with poorly-accessible contaminant mass residing within lower-permeability zones.
Brusseau, M L; Carroll, K C; Allen, T; Baker, J; Diguiseppi, W; Hatton, J; Morrison, C; Russo, A; Berkompas, J
2011-06-15
A large-scale permanganate-based in situ chemical oxidation (ISCO) effort has been conducted over the past ten years at a federal Superfund site in Tucson, AZ, for which trichloroethene (TCE) is the primary contaminant of concern. Remediation performance was assessed by examining the impact of treatment on contaminant mass discharge, an approach that has been used for only a very few prior ISCO projects. Contaminant mass discharge tests were conducted before and after permanganate injection to measure the impact at the source-zone scale. The results indicate that ISCO caused a significant reduction in mass discharge (approximately 75%). The standard approach of characterizing discharge at the source-zone scale was supplemented with additional characterization at the plume scale, which was evaluated by examining the change in contaminant mass discharge associated with the pump-and-treat system. The integrated contaminant mass discharge decreased by approximately 70%, consistent with the source-zone-scale measurements. The integrated mass discharge rebounded from 0.1 to 0.2 kg/d within one year after cessation of permanganate injections, after which it has been stable for several years. Collection of the integrated contaminant mass discharge data throughout the ISCO treatment period provided a high-resolution, real-time analysis of the site-wide impact of ISCO, thereby linking source-zone remediation to impacts on overall risk. The results indicate that ISCO was successful in reducing contaminant mass discharge at this site, which comprises a highly heterogeneous subsurface environment. Analysis of TCE sediment concentration data for core material collected before and after ISCO supports the hypothesis that the remaining mass discharge is associated in part with poorly accessible contaminant mass residing within lower-permeability zones.
Combined Sewer Overflows as a Source of Hormones to Surface Water
NASA Astrophysics Data System (ADS)
Phillips, P.; Chalmers, A.; Gray, J. L.; Foreman, W.; Kolpin, D. W.; Wall, G.; Esposito, K.
2009-12-01
Some sources of hormones to surface water, such as wastewater-treatment-plant (WWTP) effluent, have been well documented, but other sources, particularly wet-weather discharges from combined-sewer-overflows (CSOs), are not well characterized. Flow-weighted composite samples of secondarily treated WWTP effluent and untreated sewage discharges from WWTP inflows and CSO discharges were collected during 12 storms and 6 non-storm conditions from November 2007-December 2008 at the main Burlington Vermont WWTP. Concentrations of many androgens and estrogens were highest in samples from untreated sewage, and lower in samples from treated sewage. For example, concentrations of estriol in CSO samples ranged from 5 to over 100 ng/L (nanograms per liter), but were generally less than 1 ng/L in treated sewage. Many androgens were detected in CSO discharge samples in concentrations ranging from 1 to over 1000 ng/L, but were not detected above 1 ng/L in treated samples. For many of the hormones, including androgens and estriol, CSO discharges comprised over half of the total load discharged by the WWTP, even though annual CSO discharge is less than 10% of the treated plant discharge. These results indicate that untreated discharges during CSO events can be a major source of some hormones and other wastewater compounds to the environment.
Orlov, Tanya; Zohary, Ehud
2018-01-17
We typically recognize visual objects using the spatial layout of their parts, which are present simultaneously on the retina. Therefore, shape extraction is based on integration of the relevant retinal information over space. The lateral occipital complex (LOC) can represent shape faithfully in such conditions. However, integration over time is sometimes required to determine object shape. To study shape extraction through temporal integration of successive partial shape views, we presented human participants (both men and women) with artificial shapes that moved behind a narrow vertical or horizontal slit. Only a tiny fraction of the shape was visible at any instant at the same retinal location. However, observers perceived a coherent whole shape instead of a jumbled pattern. Using fMRI and multivoxel pattern analysis, we searched for brain regions that encode temporally integrated shape identity. We further required that the representation of shape should be invariant to changes in the slit orientation. We show that slit-invariant shape information is most accurate in the LOC. Importantly, the slit-invariant shape representations matched the conventional whole-shape representations assessed during full-image runs. Moreover, when the same slit-dependent shape slivers were shuffled, thereby preventing their spatiotemporal integration, slit-invariant shape information was reduced dramatically. The slit-invariant representation of the various shapes also mirrored the structure of shape perceptual space as assessed by perceptual similarity judgment tests. Therefore, the LOC is likely to mediate temporal integration of slit-dependent shape views, generating a slit-invariant whole-shape percept. These findings provide strong evidence for a global encoding of shape in the LOC regardless of integration processes required to generate the shape percept. SIGNIFICANCE STATEMENT Visual objects are recognized through spatial integration of features available simultaneously on the retina. The lateral occipital complex (LOC) represents shape faithfully in such conditions even if the object is partially occluded. However, shape must sometimes be reconstructed over both space and time. Such is the case in anorthoscopic perception, when an object is moving behind a narrow slit. In this scenario, spatial information is limited at any moment so the whole-shape percept can only be inferred by integration of successive shape views over time. We find that LOC carries shape-specific information recovered using such temporal integration processes. The shape representation is invariant to slit orientation and is similar to that evoked by a fully viewed image. Existing models of object recognition lack such capabilities. Copyright © 2018 the authors 0270-6474/18/380659-20$15.00/0.
Skoner, David P; Blaiss, Michael S; Dykewicz, Mark S; Smith, Nancy; Leatherman, Bryan; Bielory, Leonard; Walstein, Nicole; Craig, Timothy J; Allen-Ramey, Felicia
2014-01-01
Allergen immunotherapy (AIT) is used for the treatment of allergic rhinoconjunctivitis as a subcutaneous injection (subcutaneous immunotherapy [SCIT]). Extracts used for SCIT are also used off-label to formulate a liquid delivered as sublingual drops (sublingual immunotherapy [SLIT]). This study was designed to survey patients' experiences and beliefs regarding SCIT and SLIT. People who had ever been diagnosed with nasal and/or ocular allergies were identified in a 2012 telephone survey of U.S. households. Respondents were asked questions about their or their child's use of SCIT and SLIT and their beliefs about AIT. Of 2765 respondents, 46.5% had ever heard of AIT and 22.7% had ever initiated it: 20.9% with SCIT and 1.8% with SLIT (p < 0.0001). The most frequently cited reason for beginning AIT was that symptoms were unresolved with other medications (SCIT, 32.1%; SLIT, 14.0%). Some or full symptom relief was reported by 74.9% of respondents treated with SCIT and 66.0% of those treated with SLIT (p = 0.17 for SCIT versus SLIT). Approximately one-third of respondents who had ever heard of or had been treated with AIT said "don't know" when asked if immunotherapy controls allergy symptoms for years (33.6%), is a very safe treatment (29.3%), or can cure allergy symptoms (27.5%). Effective relief of allergy symptoms was cited most often as the primary benefit of SCIT (37.8%) and convenience was the primary benefit of SLIT (14%). Only one-fifth of respondents had ever been treated with AIT, largely with SCIT. More than one-half of respondents had never heard of AIT and respondents' beliefs indicated a need for educational efforts.
Collimator Design for a Brain SPECT/MRI Insert
NASA Astrophysics Data System (ADS)
Salvado, Debora; Erlandsson, Kjell; Bousse, Alexandre; Occhipinti, Michele; Busca, Paolo; Fiorini, Carlo; Hutton, Brian F.
2015-08-01
This project's goal is to design a SPECT insert for a clinical MRI system for simultaneous brain SPECT/MR imaging, with a high-sensitivity collimator and high-resolution detectors. We have compared eight collimator designs, four multi-pinhole and four multi-slit slit-slat configurations. The collimation was designed for a system with 2 rings of 25 5 × 5 cm detectors. We introduce the concept of 1/2-pinhole and 1/2-slit, which are transaxially shared between two adjacent detectors. Analytical geometric efficiency was calculated for an activity distribution corresponding to a human brain and a range of intrinsic detector resolutions Ri and target resolutions Rt at the centre of the FOV. Noise-free data were simulated with and without depth-of-interaction (DOI) information, 0.8 mm Ri and 10 mm Rt FWHM, and reconstructed for uniform, Defrise, Derenzo, and Zubal brain phantoms. Comparing the multi-pinhole and multi-slit slit-slat collimators, the former gives better reconstructed uniformity and transaxial resolution, while the latter gives better axial resolution. Although the 2 ×2-pinhole and 2-slit designs give the highest sensitivities, they result in a sub-optimal utilisation of the detector FOV. The best options are therefore the 5+ 2 1/2-pinhole and the 1 + 2 1/2-slit systems, with sensitivities of 1.8 ×10-4 and 3.2 ×10-4, respectively. Noiseless brain phantom reconstructions with the multi-pinhole collimator are slightly superior as compared to slit-slat, in terms of symmetry and accuracy of the activity distribution, but the same is not true when noise is included. DOI information reduces artefacts and improves uniformity in geometric phantoms. Further evaluation is needed with prototype collimators.
NASA Technical Reports Server (NTRS)
Yuan, S. W. K.; Lee, J. M.; Frederking, T. H. K.
1988-01-01
The turbulent transport mode of vapor liquid phase separators (VLPS) for He II has been investigated comparing passive porous plug separators with active phase separators (APS) using slits of variable flow paths within a common frame of reference. It is concluded that the basic transport regimes in both devices are identical. An integrated Gorter-Mellink (1949) equation, found previously to predict VLPS results of porous plugs, is employed to analyze APS data published in the literature. It is found that the Gorter-Mellink flow rate parameter for 9-micron and 14-micron APS slit widths are relatively independent of the slit width, having a rate constant of about 9 + or - 10 percent. This agrees with the early heat flow results for He II entropy transport at zero net mass flow in wide capillaries and slits.
Kiyokawa, Masatoshi; Sakuma, Toshiro; Hatano, Noriko; Mizota, Atsushi; Tanaka, Minoru
2009-06-01
The purpose of this article is to report the characteristics and advantages of using a newly designed quartz contact lens with slit illumination from an operating microscope for intraocular surgery. The new contact lens is made of quartz. The lens is convex-concave and is used in combination with slit illumination from an operating microscope. The optical properties of quartz make this lens less reflective with greater transmittance. The combination of a quartz contact lens with slit illumination provided a brighter and wider field of view than conventional lenses. This system enabled us to perform bimanual vitrectomy and scleral buckling surgery without indirect ophthalmoscope. Small intraocular structures in the posterior pole or in the periphery were detected more easily. In conclusion, the newly designed quartz lens with slit beam illumination from an operating microscope provided a bright, clear and wide surgical field, and allowed intraocular surgery to be performed more easily.
A Computational and Experimental Study of Slit Resonators
NASA Technical Reports Server (NTRS)
Tam, C. K. W.; Ju, H.; Jones, M. G.; Watson, W. R.; Parrott, T. L.
2003-01-01
Computational and experimental studies are carried out to offer validation of the results obtained from direct numerical simulation (DNS) of the flow and acoustic fields of slit resonators. The test cases include slits with 90-degree corners and slits with 45-degree bevel angle housed inside an acoustic impedance tube. Three slit widths are used. Six frequencies from 0.5 to 3.0 kHz are chosen. Good agreement is found between computed and measured reflection factors. In addition, incident sound waves having white noise spectrum and a prescribed pseudo-random noise spectrum are used in subsequent series of tests. The computed broadband results are again found to agree well with experimental data. It is believed the present results provide strong support that DNS can eventually be a useful and accurate prediction tool for liner aeroacoustics. The usage of DNS as a design tool is discussed and illustrated by a simple example.
Investigation on Multiple-Pulse Propulsion Performance for a Parabolic Nozzle with Inlet Slit
NASA Astrophysics Data System (ADS)
Wen, Ming; Hong, Yanji; Song, Junling
2011-11-01
The multiple-pulse impulse coupling coefficient Cm is lower than the single pulse one with the same laser parameters. It is always explained that air recovery in nozzle does not work on time. Three kinds of parabolic nozzles are employed to improve air recovery in the experiments and simulation. There exist inlet slits on side wall of them with width of 1 mm, 2 mm, respectively. The curves of thrust and the process of flow fluid field are presented to study the slit effects on Cm under 20 Hz pulse frequency. The results show: an inlet slit can accelerate the air breathing process in the nozzle and Cm for each pulse exhibits a little variation; the lower Cm is obtained due to the increasing energy loss by a larger size slit; the flat-roofed nozzle gets higher Cm than others.
Coleman, Hope A.; Labrador, Juan-Pablo; Chance, Rebecca K.; Bashaw, Greg J.
2010-01-01
Slits and their Roundabout (Robo) receptors mediate repulsive axon guidance at the Drosophila ventral midline and in the vertebrate spinal cord. Slit is cleaved to produce fragments with distinct signaling properties. In a screen for genes involved in Slit-Robo repulsion, we have identified the Adam family metalloprotease Kuzbanian (Kuz). Kuz does not regulate midline repulsion through cleavage of Slit, nor is Slit cleavage essential for repulsion. Instead, Kuz acts in neurons to regulate repulsion and Kuz can cleave the Robo extracellular domain in Drosophila cells. Genetic rescue experiments using an uncleavable form of Robo show that this receptor does not maintain normal repellent activity. Finally, Kuz activity is required for Robo to recruit its downstream signaling partner, Son of sevenless (Sos). These observations support the model that Kuz-directed cleavage is important for Robo receptor activation. PMID:20570941
Slit scan radiographic system for intermediate size rocket motors
NASA Astrophysics Data System (ADS)
Bernardi, Richard T.; Waters, David D.
1992-12-01
The development of slit-scan radiography capability for the NASA Advanced Computed Tomography Inspection System (ACTIS) computed tomography (CT) scanner at MSFC is discussed. This allows for tangential case interface (bondline) inspection at 2 MeV of intermediate-size rocket motors like the Hawk. Motorized mounting fixture hardware was designed, fabricated, installed, and tested on ACTIS. The ACTIS linear array of x-ray detectors was aligned parallel to the tangent line of a horizontal Hawk motor case. A 5 mm thick x-ray fan beam was used. Slit-scan images were produced with continuous rotation of a horizontal Hawk motor. Image features along Hawk motor case interfaces were indicated. A motorized exit cone fixture for ACTIS slit-scan inspection was also provided. The results of this SBIR have shown that slit scanning is an alternative imaging technique for case interface inspection. More data is required to qualify the technique for bondline inspection.
Teruya, Alan T [Livermore, CA; Elmer,; John, W [Danville, CA; Palmer, Todd A [State College, PA
2011-03-08
A diagnostic system for characterization of an electron beam or an ion beam includes an electrical conducting disk of refractory material having a circumference, a center, and a Faraday cup assembly positioned to receive the electron beam or ion beam. At least one slit in the disk provides diagnostic characterization of the electron beam or ion beam. The at least one slit is located between the circumference and the center of the disk and includes a radial portion that is in radial alignment with the center and a portion that deviates from radial alignment with the center. The electron beam or ion beam is directed onto the disk and translated to the at least one slit wherein the electron beam or ion beam enters the at least one slit for providing diagnostic characterization of the electron beam or ion beam.
Emittance studies of the 2.45 GHz permanent magnet ECR ion source
NASA Astrophysics Data System (ADS)
Zelenak, A.; Bogomolov, S. L.; Yazvitsky, N. Yu.
2004-05-01
During the past several years different types of permanent magnet 2.45 GHz (electron cyclotron resonance) ion sources were developed for production of singly charged ions. Ion sources of this type are used in the first stage of DRIBs project, and are planned to be used in the MASHA mass separator. The emittance of the beam provided by the source is one of the important parameters for these applications. An emittance scanner composed from a set of parallel slits and rotary wire beam profile monitor was used for the studying of the beam emittance characteristics. The emittance of helium and argon ion beams was measured with different shapes of the plasma electrode for several ion source parameters: microwave power, source potential, plasma aperture-puller aperture gap distance, gas pressure. The results of measurements are compared with previous simulations of ion optics.
Pizzi, Rita; Wang, Rui; Rossetti, Danilo
2016-01-01
This paper describes a computational approach to the theoretical problems involved in the Young's single-photon double-slit experiment, focusing on a simulation of this experiment in the absence of measuring devices. Specifically, the human visual system is used in place of a photomultiplier or similar apparatus. Beginning with the assumption that the human eye perceives light in the presence of very few photons, we measure human eye performance as a sensor in a double-slit one-photon-at-a-time experimental setup. To interpret the results, we implement a simulation algorithm and compare its results with those of human subjects under identical experimental conditions. In order to evaluate the perceptive parameters exactly, which vary depending on the light conditions and on the subject’s sensitivity, we first review the existing literature on the biophysics of the human eye in the presence of a dim light source, and then use the known values of the experimental variables to set the parameters of the computational simulation. The results of the simulation and their comparison with the experiment involving human subjects are reported and discussed. It is found that, while the computer simulation indicates that the human eye has the capacity to detect the corpuscular nature of photons under these conditions, this was not observed in practice. The possible reasons for the difference between theoretical prediction and experimental results are discussed. PMID:26816029
Sensitive glow discharge ion source for aerosol and gas analysis
Reilly, Peter T. A. [Knoxville, TN
2007-08-14
A high sensitivity glow discharge ion source system for analyzing particles includes an aerodynamic lens having a plurality of constrictions for receiving an aerosol including at least one analyte particle in a carrier gas and focusing the analyte particles into a collimated particle beam. A separator separates the carrier gas from the analyte particle beam, wherein the analyte particle beam or vapors derived from the analyte particle beam are selectively transmitted out of from the separator. A glow discharge ionization source includes a discharge chamber having an entrance orifice for receiving the analyte particle beam or analyte vapors, and a target electrode and discharge electrode therein. An electric field applied between the target electrode and discharge electrode generates an analyte ion stream from the analyte vapors, which is directed out of the discharge chamber through an exit orifice, such as to a mass spectrometer. High analyte sensitivity is obtained by pumping the discharge chamber exclusively through the exit orifice and the entrance orifice.
Managing commercial and light-industrial discharges to POTWs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fink, R.G.
1993-02-01
Discharging commercial and light-industrial wastewater to a publicly owned treatment works (POTW) is risky business. Pretreating wastewater using traditional methods may leave a wastestream's originator vulnerable to fines, civil and criminal punishment, cleanup costs, and cease-and-desist orders. EPA has tightened regulations applying to discharges from POTWs, which, in turn, are looking to industrial and commercial discharge sources to determine responsibility for toxic contaminants. Although EPA in the past focused on large point sources of contamination, the Agency has shifted its emphasis to smaller and more diverse nonpoint sources. One result is that POTWs no longer act as buffers for light-industrialmore » and commercial wastewater dischargers.« less
Combined corona discharge and UV photoionization source for ion mobility spectrometry.
Bahrami, Hamed; Tabrizchi, Mahmoud
2012-08-15
An ion mobility spectrometer is described which is equipped with two non-radioactive ion sources, namely an atmospheric pressure photoionization and a corona discharge ionization source. The two sources cannot only run individually but are additionally capable of operating simultaneously. For photoionization, a UV lamp was mounted parallel to the axis of the ion mobility cell. The corona discharge electrode was mounted perpendicular to the UV radiation. The total ion current from the photoionization source was verified as a function of lamp current, sample flow rate, and drift field. Simultaneous operation of the two ionization sources was investigated by recording ion mobility spectra of selected samples. The design allows one to observe peaks from either the corona discharge or photoionization individually or simultaneously. This makes it possible to accurately compare peaks in the ion mobility spectra from each individual source. Finally, the instrument's capability for discriminating two peaks appearing in approximately identical drift times using each individual ionization source is demonstrated. Copyright © 2012 Elsevier B.V. All rights reserved.
Onai, M; Etoh, H; Aoki, Y; Shibata, T; Mattei, S; Fujita, S; Hatayama, A; Lettry, J
2016-02-01
Recently, a filament driven multi-cusp negative ion source has been developed for proton cyclotrons in medical applications. In this study, numerical modeling of the filament arc-discharge source plasma has been done with kinetic modeling of electrons in the ion source plasmas by the multi-cusp arc-discharge code and zero dimensional rate equations for hydrogen molecules and negative ions. In this paper, main focus is placed on the effects of the arc-discharge power on the electron energy distribution function and the resultant H(-) production. The modelling results reasonably explains the dependence of the H(-) extraction current on the arc-discharge power in the experiments.
Pink-Beam, Highly-Accurate Compact Water Cooled Slits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lyndaker, Aaron; Deyhim, Alex; Jayne, Richard
2007-01-19
Advanced Design Consulting, Inc. (ADC) has designed accurate compact slits for applications where high precision is required. The system consists of vertical and horizontal slit mechanisms, a vacuum vessel which houses them, water cooling lines with vacuum guards connected to the individual blades, stepper motors with linear encoders, limit (home position) switches and electrical connections including internal wiring for a drain current measurement system. The total slit size is adjustable from 0 to 15 mm both vertically and horizontally. Each of the four blades are individually controlled and motorized. In this paper, a summary of the design and Finite Elementmore » Analysis of the system are presented.« less
NASA Astrophysics Data System (ADS)
Hausmann, Michael; Doelle, Juergen; Arnold, Armin; Stepanow, Boris; Wickert, Burkhard; Boscher, Jeannine; Popescu, Paul C.; Cremer, Christoph
1992-07-01
Laser fluorescence activated slit-scan flow cytometry offers an approach to a fast, quantitative characterization of chromosomes due to morphological features. It can be applied for screening of chromosomal abnormalities. We give a preliminary report on the development of the Heidelberg slit-scan flow cytometer. Time-resolved measurement of the fluorescence intensity along the chromosome axis can be registered simultaneously for two parameters when the chromosome axis can be registered simultaneously for two parameters when the chromosome passes perpendicularly through a narrowly focused laser beam combined by a detection slit in the image plane. So far automated data analysis has been performed off-line on a PC. In its final performance, the Heidelberg slit-scan flow cytometer will achieve on-line data analysis that allows an electro-acoustical sorting of chromosomes of interest. Interest is high in the agriculture field to study chromosome aberrations that influence the size of litters in pig (Sus scrofa domestica) breeding. Slit-scan measurements have been performed to characterize chromosomes of pigs; we present results for chromosome 1 and a translocation chromosome 6/15.
Plasma-surface interaction in negative hydrogen ion sources
NASA Astrophysics Data System (ADS)
Wada, Motoi
2018-05-01
A negative hydrogen ion source delivers more beam current when Cs is introduced to the discharge, but a continuous operation of the source reduces the beam current until more Cs is added to the source. This behavior can be explained by adsorption and ion induced desorption of Cs atoms on the plasma grid surface of the ion source. The interaction between the ion source plasma and the plasma grid surface of a negative hydrogen ion source is discussed in correlation to the Cs consumption of the ion source. The results show that operation with deuterium instead of hydrogen should require more Cs consumption and the presence of medium mass impurities as well as ions of the source wall materials in the arc discharge enlarges the Cs removal rate during an ion source discharge.
A cookbook for building a high-current dimpled H – magnetron source for accelerators
Bollinger, Daniel S.; Karns, Patrick R.; Tan, Cheng -Yang
2015-10-30
A high-current (>50 mA) dimpled H – magnetron source has been built at Fermilab for supplying H – beam to the entire accelerator complex. Despite many decades of expertise with slit H – magnetron sources at Fermilab, we were faced with many challenges from the dimpled H – magnetron source, which needed to be overcome in order to make it operational. Dimpled H – sources for high-energy physics are not new: Brookhaven National Laboratory has operated a dimpled H- source for more than two decades. However, the transference of that experience to Fermilab took about two years because a cookbookmore » for building this type of source did not exist and seemingly innocuous or undocumented choices had a huge impact on the success or failure for this type of source. Moreover, it is the goal of this paper to document the reasons for these choices and to present a cookbook for building and operating dimpled H – magnetron sources.« less
NASA Astrophysics Data System (ADS)
Cenedese, C.
2014-12-01
Idealized laboratory experiments investigate the glacier-ocean boundary dynamics near a vertical 'glacier' (i.e. no floating ice tongue) in a two-layer stratified fluid, similar to Sermilik Fjord where Helheim Glacier terminates. In summer, the discharge of surface runoff at the base of the glacier (subglacial discharge) intensifies the circulation near the glacier and increases the melt rate with respect to that in winter. In the laboratory, the effect of subglacial discharge is simulated by introducing fresh water at melting temperatures from either point or line sources at the base of an ice block representing the glacier. The circulation pattern observed both with and without subglacial discharge resembles those observed in previous studies. The buoyant plume of cold meltwater and subglacial discharge water entrains ambient water and rises vertically until it finds either the interface between the two layers or the free surface. The results suggest that the meltwater deposits within the interior of the water column and not entirely at the free surface, as confirmed by field observations. The submarine melt rate increases with the subglacial discharge rate. Furthermore, the same subglacial discharge causes greater submarine melting if it exits from a point source rather than from a line source. When the subglacial discharge exits from two point sources, two buoyant plumes are formed which rise vertically and interact. The results suggest that the distance between the two subglacial discharges influences the entrainment in the plumes and consequently the amount of submarine melting and the final location of the meltwater within the water column. Hence, the distribution and number of sources of subglacial discharge may play an important role in glacial melt rates and fjord stratification and circulation. Support was given by NSF project OCE-113008.
Quality of life outcomes with sublingual immunotherapy.
Wise, Sarah K; Woody, Jamie; Koepp, Sarah; Schlosser, Rodney J
2009-01-01
Immunotherapy is the titrated exposure of allergens to induce immunologic tolerance and offers long-term immune modification. Traditional subcutaneous immunotherapy (SCIT) has resulted in several deaths and raised safety concerns. Sublingual immunotherapy (SLIT) is an alternative administration route for allergen-specific immunotherapy. Compared to SCIT, SLIT has a shorter escalation phase, equal or greater efficacy for rhinitis, and an improved safety profile. The purpose of this study was to evaluate quality of life measures in a preliminary patient sample initiating SLIT at our institution. Patients with appropriate allergen reactivity were given the option to pursue immunotherapy by traditional SCIT or by SLIT techniques. Patients choosing SLIT completed the mini-Rhinoconjunctivitis Quality of Life Questionnaire (m-RQLQ), a 14-item Likert-type questionnaire, at baseline and during maintenance therapy. Patients typically reached maintenance dosing in less than 5 weeks. Paired m-RQLQ data were available for 15 patients after antigen titration. Initial m-RQLQ results indicate statistically significant (P < .05) improvement on 12 of 14 domains, including impact on regular and recreational activities, sleep, nose rubbing and nose blowing, stuffy nose and runny nose, itchy eyes, sore eyes, watery eyes, thirst, and tiredness. In addition, total m-RQLQ score showed statistically significant improvement (P = .001). No serious adverse events occurred with the initiation of SLIT. These results indicate that SLIT is effective in controlling allergic symptoms and is safe in an introductory patient sample. Double-blind placebo-controlled trials are needed to confirm our preliminary results.
Drosophila Neurexin IV Interacts with Roundabout and is Required for Repulsive Midline Axon Guidance
Banerjee, Swati; Blauth, Kevin; Peters, Kimberly; Rogers, Stephen L.; Fanning, Alan S.; Bhat, Manzoor A.
2010-01-01
Slit/Roundabout (Robo) signaling controls midline repulsive axon guidance. However, proteins that interact with Slit/Robo at the cell surface remain largely uncharacterized. Here, we report that the Drosophila transmembrane septate junction-specific protein, Neurexin IV (Nrx IV), functions in midline repulsive axon guidance. Nrx IV is expressed in the neurons of the developing ventral nerve cord and nrx IV mutants show crossing and circling of ipsilateral axons and fused commissures. Interestingly, the axon guidance defects observed in nrx IV mutants seem independent of its other binding partners such as Contactin and Neuroglian and the midline glia protein Wrapper that interacts in trans with Nrx IV. nrx IV mutants show diffuse Robo localization and dose-dependent genetic interactions between nrx IV/robo and nrx IV/slit indicate that they function in a common pathway. In vivo biochemical studies reveal that Nrx IV associates with Robo, Slit and Syndecan, and interactions between Robo and Slit, or Nrx IV and Slit, are affected in nrx IV and robo mutants, respectively. Coexpression of Nrx IV and Robo in mammalian cells confirms that these proteins retain the ability to interact in a heterologous system. Furthermore, we demonstrate that the extracellular region of Nrx IV is sufficient to rescue Robo localization and axon guidance phenotypes in nrx IV mutants. Together our studies establish that Nrx IV is essential for proper Robo localization, and identify Nrx IV as a novel interacting partner of the Slit/Robo signaling pathway. PMID:20410118
Banerjee, Swati; Blauth, Kevin; Peters, Kimberly; Rogers, Stephen L; Fanning, Alan S; Bhat, Manzoor A
2010-04-21
Slit/Roundabout (Robo) signaling controls midline repulsive axon guidance. However, proteins that interact with Slit/Robo at the cell surface remain largely uncharacterized. Here, we report that the Drosophila transmembrane septate junction-specific protein Neurexin IV (Nrx IV) functions in midline repulsive axon guidance. Nrx IV is expressed in the neurons of the developing ventral nerve cord, and nrx IV mutants show crossing and circling of ipsilateral axons and fused commissures. Interestingly, the axon guidance defects observed in nrx IV mutants seem independent of its other binding partners, such as Contactin and Neuroglian and the midline glia protein Wrapper, which interacts in trans with Nrx IV. nrx IV mutants show diffuse Robo localization, and dose-dependent genetic interactions between nrx IV/robo and nrx IV/slit indicate that they function in a common pathway. In vivo biochemical studies reveal that Nrx IV associates with Robo, Slit, and Syndecan, and interactions between Robo and Slit, or Nrx IV and Slit, are affected in nrx IV and robo mutants, respectively. Coexpression of Nrx IV and Robo in mammalian cells confirms that these proteins retain the ability to interact in a heterologous system. Furthermore, we demonstrate that the extracellular region of Nrx IV is sufficient to rescue Robo localization and axon guidance phenotypes in nrx IV mutants. Together, our studies establish that Nrx IV is essential for proper Robo localization and identify Nrx IV as a novel interacting partner of the Slit/Robo signaling pathway.
Novel Technique for Rebubbling DMEK Grafts at the Slit Lamp Using Intravenous Extension Tubing.
Sáles, Christopher S; Straiko, Michael D; Terry, Mark A
2016-04-01
To describe a novel technique for rebubbling DMEK grafts at the slit lamp using a cannula coupled to a syringe with intravenous (IV) extension tubing. We present a retrospective case series of eyes that underwent rebubbling using a novel technique at the slit lamp. The rebubbling apparatus is assembled using a standard 43-inch IV extension tube, a 5-cc luer lock syringe, and a 27-gauge cannula. The cannula is screwed onto one end of the extension tubing, and a 5-cc syringe that has been filled with air is screwed onto the opposite end. With the patient seated at the slit lamp, the cannula is positioned in the anterior chamber by the surgeon with one hand while the other hand operates the syringe and the joystick. We performed 5 rebubbling procedures at the slit lamp using a standard syringe and cannula. Despite suboptimal ergonomics with this approach, all of these cases achieved sufficient air fills without any complications. Four rebubbling procedures were subsequently performed at the slit lamp using our novel rebubbling technique. All of these cases also attained sufficient air fills without complications, but they were noted to be much easier to perform by the surgeon. Using IV extension tubing to couple a syringe to a cannula for rebubbling DMEK grafts at the slit lamp is ergonomically superior to the conventional alternative of using a standard cannula on a syringe. The technique is also simple and inexpensive to adopt.
Immunological mechanisms of sublingual allergen-specific immunotherapy.
Novak, Natalija; Bieber, T; Allam, J-P
2011-06-01
Within the last 100 years of allergen-specific immunotherapy, many clinical and scientific efforts have been made to establish alternative noninvasive allergen application strategies. Thus, intra-oral allergen delivery to the sublingual mucosa has been proven to be safe and effective. As a consequence, to date, sublingual immunotherapy (SLIT) is widely accepted by most allergists as an alternative to conventional subcutaneous immunotherapy. Although immunological mechanisms remain to be elucidated in detail, several studies in mice and humans within recent years provided deeper insights into local as well as systemic immunological features in response to SLIT. First of all, it was shown that the target organ, the oral mucosa, harbours a sophisticated immunological network as an important prerequisite for SLIT, which contains among other cells, local antigen-presenting cells (APC), such as dendritic cells (DCs), with a constitutive disposition to enforce tolerogenic mechanisms. Further on, basic research on local DCs within the oral mucosa gave rise to possible alternative strategies to deliver the allergens to other mucosal regions than sublingual tissue, such as the vestibulum oris. Moreover, characterization of oral DCs led to the identification of target structures for both allergens as well as adjuvants, which could be applied during SLIT. Altogether, SLIT came a long way since its very beginning in the last century and some, but not all questions about SLIT could be answered so far. However, recent research efforts as well as clinical approaches paved the way for another exciting 100 years of SLIT. © 2011 John Wiley & Sons A/S.
Temporal variation in spatial sources of mercury loading to rivers (presentation)
Source areas within the Fox River watershed (WI, USA) were mapped for individual discharge events. The spatial distribution of source areas varied between, and over the duration of, individual discharge events. The percent contribution of runoff by land cover type within source a...
SPECIAL ANALYSIS OF OPERATIONAL STORMWATER RUNOFF COVERS OVER SLIT TRENCHES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Collard, L; Luther Hamm, L
2008-12-18
Solid Waste Management (SWM) commissioned this Special Analysis (SA) to determine the effects of placing operational stormwater runoff covers (referred to as covers in the remainder of this document) over slit trench (ST) disposal units ST1 through ST7 (the center set of slit trenches). Previously the United States Department of Energy (DOE) entered into an agreement with the United States Environmental Protection Agency (EPA) and the South Carolina Department of Health and Environmental Control (SCDHEC) to place covers over Slit Trenches 1 and 2 to be able to continue disposing Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) solid wastemore » (see USDOE 2008). Because the covers changed the operating conditions, DOE Order 435.1 (DOE 1999) required that an SA be performed to assess the impact. This Special Analysis has been prepared to determine the effects of placing covers over slit trenches at about years 5, 10 and 15 of the 30-year operational period. Because some slit trenches have already been operational for about 15 years, results from analyzing covers at 5 years and 10 years provide trend analysis information only. This SA also examined alternatives of covering Slit Trenches 1 and 2 with one cover and Slit Trenches 3 and 4 with a second cover versus covering them all with a single cover. Based on modeling results, minimal differences exist between covering Slit Trench groups 1-2 and 3-4 with two covers or one large cover. This SA demonstrates that placement of covers over slit trenches will slow the subsequent release and transport of radionuclides in the vadose zone in the early time periods (from time of placement until about 100 years). Release and transport of some radionuclides in the vadose zone beyond 100 years were somewhat higher than for the case without covers. The sums-of-fractions (SOFs) were examined for the current waste inventory in ST1 and ST2 and for estimated inventories at closure for ST3 through ST7. In all cases SOFs were less than one (except for one SOF for ST5 that remained at one), indicating that there should be no unacceptable impacts on operations from placing covers for the cover alternatives that were analyzed. Minimal operational limits provided in Table 4 should be used as the new set of limits for Slit Trenches 1 through 7. ST1 and ST2 are expected to be covered about 15 years after the first disposal in ST1. Because the time of actual placement of covers over the other slit trenches is unknown, this SA did not consider limit increases, only limit decreases. Thus, each minimal operational limit is the minimum of the Performance Assessment (PA) final limit and the limit calculated in this SA if covers were placed at about 5, 10 or 15 years. If other cover times are desired, further analysis will be required.« less
Large area, surface discharge pumped, vacuum ultraviolet light source
Sze, Robert C.; Quigley, Gerard P.
1996-01-01
Large area, surface discharge pumped, vacuum ultraviolet (VUV) light source. A contamination-free VUV light source having a 225 cm.sup.2 emission area in the 240-340 nm region of the electromagnetic spectrum with an average output power in this band of about 2 J/cm.sup.2 at a wall-plug efficiency of approximately 5% is described. Only ceramics and metal parts are employed in this surface discharge source. Because of the contamination-free, high photon energy and flux, and short pulse characteristics of the source, it is suitable for semiconductor and flat panel display material processing.
MAXI/GSC 7-year Source Catalog
NASA Astrophysics Data System (ADS)
Ueda, Y.; Kawamuro, T.; Hori, T.; Shidatsu, M.; Tanimoto, A.; MAXI Team
2017-10-01
Monitor of All-sky X-ray Image (MAXI) on the International Space Station has been continuously observing the X-ray sky since its launch in 2009. The MAXI survey has achieved the best sensitivity in the 4-10 keV band as an all sky X-ray mission, and is complementary to the ROSAT all sky survey (<2 keV) and hard X-ray (>10 keV) surveys performed with Swift and INTEGRAL. Here we present the latest source catalog of MAXI/Gas Slit Camera (GSC) constructed from the first 7-year data, which is an extension of the 37-month catalog of the high Galactic-latitude sky (Hiroi et al. 2013). We summarize statistical properties of the X-ray sources and results of cross identification with other catalogs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chang, Chih-Hsuan; Nesbitt, David J.
A series of CH stretch modes in phenyl radical (C{sub 6}H{sub 5}) has been investigated via high resolution infrared spectroscopy at sub-Doppler resolution (∼60 MHz) in a supersonic discharge slit jet expansion. Two fundamental vibrations of a{sub 1} symmetry, ν{sub 1} and ν{sub 2}, are observed and rotationally analyzed for the first time, corresponding to in-phase and out-of-phase symmetric CH stretch excitation at the ortho/meta/para and ortho/para C atoms with respect to the radical center. The ν{sub 1} and ν{sub 2} band origins are determined to be 3073.968 50(8) cm{sup −1} and 3062.264 80(7) cm{sup −1}, respectively, which both agree within 5more » cm{sup −1} with theoretical anharmonic scaling predictions based on density functional B3LYP/6-311g++(3df,3dp) calculations. Integrated band strengths for each of the CH stretch bands are analyzed, with the relative intensities agreeing remarkably well with theoretical predictions. Frequency comparison with previous low resolution Ar-matrix spectroscopy [A. V. Friderichsen et al., J. Am. Chem. Soc. 123, 1977 (2001)] reveals a nearly uniform Δν ≈ + 10-12 cm{sup −1} blue shift between gas phase and Ar matrix values for ν{sub 1} and ν{sub 2}. This differs substantially from the much smaller red shift (Δν ≈ − 1 cm{sup −1}) reported for the ν{sub 19} mode, and suggests a simple physical model in terms of vibrational mode symmetry and crowding due to the matrix environment. Finally, the infrared phenyl spectra are well described by a simple asymmetric rigid rotor Hamiltonian and show no evidence for spectral congestion due to intramolecular vibrational coupling, which bodes well for high resolution studies of other ring radicals and polycyclic aromatic hydrocarbons. In summary, the combination of slit jet discharge methods with high resolution infrared lasers enables spectroscopic investigation of even highly reactive combustion and interstellar radical intermediates under gas phase, jet-cooled (T{sub rot} ≈ 11 K) conditions.« less
NASA Astrophysics Data System (ADS)
Chang, Chih-Hsuan; Nesbitt, David J.
2016-07-01
A series of CH stretch modes in phenyl radical (C6H5) has been investigated via high resolution infrared spectroscopy at sub-Doppler resolution (˜60 MHz) in a supersonic discharge slit jet expansion. Two fundamental vibrations of a1 symmetry, ν1 and ν2, are observed and rotationally analyzed for the first time, corresponding to in-phase and out-of-phase symmetric CH stretch excitation at the ortho/meta/para and ortho/para C atoms with respect to the radical center. The ν1 and ν2 band origins are determined to be 3073.968 50(8) cm-1 and 3062.264 80(7) cm-1, respectively, which both agree within 5 cm-1 with theoretical anharmonic scaling predictions based on density functional B3LYP/6-311g++(3df,3dp) calculations. Integrated band strengths for each of the CH stretch bands are analyzed, with the relative intensities agreeing remarkably well with theoretical predictions. Frequency comparison with previous low resolution Ar-matrix spectroscopy [A. V. Friderichsen et al., J. Am. Chem. Soc. 123, 1977 (2001)] reveals a nearly uniform Δν ≈ + 10-12 cm-1 blue shift between gas phase and Ar matrix values for ν1 and ν2. This differs substantially from the much smaller red shift (Δν ≈ - 1 cm-1) reported for the ν19 mode, and suggests a simple physical model in terms of vibrational mode symmetry and crowding due to the matrix environment. Finally, the infrared phenyl spectra are well described by a simple asymmetric rigid rotor Hamiltonian and show no evidence for spectral congestion due to intramolecular vibrational coupling, which bodes well for high resolution studies of other ring radicals and polycyclic aromatic hydrocarbons. In summary, the combination of slit jet discharge methods with high resolution infrared lasers enables spectroscopic investigation of even highly reactive combustion and interstellar radical intermediates under gas phase, jet-cooled (Trot ≈ 11 K) conditions.
The optical slit sensor as a standard sensor for spacecraft attitude determination
NASA Technical Reports Server (NTRS)
Wertz, J.
1975-01-01
The basic concept of an optical slit sensor as a standard altitude sensor is considered for any missions using a spinning spacecraft or where rotating sensors or mirrors could be used. Information available from a single sensor or from two sensors is analyzed. A standard slit sensor package is compared with the altitude package flown on the first synchronous meteorological satellite.
Effect of aperture geometry on heat transfer in tilted partially open cavities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elsayed, M.M.; Chakroun, W.
1999-11-01
Heat transfer in cavities is receiving increasing attention because of the various applications in engineering; e.g., passive solar heating, energy conservation in buildings, solar concentrating receivers, and electronic equipment. Here, convection from a square, tilted partially open cavity was investigated experimentally. The experiment was carried out to study the effect of the aperture geometry on the heat transfer between the cavity and the surrounding air. Four different geometrical arrangements for the opening were investigated: (1) high wall slit, (2) low wall slit, (3) centered wall slit, and (4) uniform wall slots. Each opening arrangement was studied at opening ratios (i.e.,more » ratio of opening height to cavity height) of 0.25, 0.5, and 0.75. The average heat transfer coefficient between the cavity and the surrounding air was estimated for each geometrical arrangement for tilt angles ranging from {minus}90 deg to +90 deg with increments of 15 deg and at a constant heat flux Grashof number of 5.5 x 10{sup 8}. The results showed that for tilt angles between 90 and 75 deg, the heat transfer coefficient has a small value that is independent of the geometrical arrangement of the opening. The value of the heat transfer coefficient increases sharply with decreasing tilt angle until an angle value of zero degrees is reached. The increase in the heat transfer coefficient continues in the negative range of tilt angle but not in the same rate as in the positive range of the tilt angle. The uniform slot arrangement gave in general higher heat transfer coefficient than the other three arrangements of the opening. Large differences in the heat transfer coefficient were observed between the high and the low wall slits where the high wall slit is found to transfer more heat to the surroundings than the low wall slit. Correlations were developed to predict the average Nusselt number of the cavity in terms of the opening ratio and the cavity tilt angle for cavities with high wall slit, low wall slit, centered wall slit, and the uniform wall slots.« less
Heat recovery system employing a temperature controlled variable speed fan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, W.T.
1986-05-20
A heat recovery system is described for use in recovering heat from an industrial process producing a heated fluid comprising: a source of inlet air; a housing coupled to the source and including a heat exchanger; means for passing the heated fluid through the heat exchanger; the housing including means for moving a variable volume of air adjustable over a continuous range from the source through the heat exchanger; air discharge means communicating with the housing for discharging air which has passed through the heat exchanger; a control system including first temperature sensing means for sensing the discharge temperature ofmore » the discharge air moving through the discharge means and a control circuit coupled to the first temperature sensing means and to the moving means for varying the volume of air moved in response to the sensed discharge temperature to control the temperature of discharge air passing through the discharge means at a first predetermined value; and the control system including second temperature sensing means for sensing the temperature of the source of inlet air and valve means coupled to and controlled by the control circuit to cause liquid to bypass the heat exchanger when the inlet air temperature rises above a second predetermined value.« less
Alternating current corona discharge/atmospheric pressure chemical ionization for mass spectrometry.
Habib, Ahsan; Usmanov, Dilshadbek; Ninomiya, Satoshi; Chen, Lee Chuin; Hiraoka, Kenzo
2013-12-30
Although alternating current (ac) corona discharge has been widely used in the fields of material science and technology, no reports have been published on its application to an atmospheric pressure chemical ionization (APCI) ion source. In this work, ac corona discharge for an APCI ion source has been examined for the first time. The ambient atmospheric pressure ac corona discharge (15 kHz, 2.6 kVptp ) was generated by using a stainless steel acupuncture needle. The generated ions were measured using an ion trap mass spectrometer. A comparative study on ac and direct current (dc) corona APCI ion sources was carried out using triacetone triperoxide and trinitrotoluene as test samples. The ac corona discharge gave ion signals as strong as dc corona discharge for both positive and negative ion modes. In addition, softer ionization was obtained with ac corona discharge than with dc corona discharge. The erosion of the needle tip induced by ac corona was less than that obtained with positive mode dc corona. A good 'yardstick' for assessing ac corona is that it can be used for both positive and negative ion modes without changing the polarity of the high-voltage power supply. Thus, ac corona can be an alternative to conventional dc corona for APCI ion sources. Copyright © 2013 John Wiley & Sons, Ltd.
[Automatic adjustment control system for DC glow discharge plasma source].
Wan, Zhen-zhen; Wang, Yong-qing; Li, Xiao-jia; Wang, Hai-zhou; Shi, Ning
2011-03-01
There are three important parameters in the DC glow discharge process, the discharge current, discharge voltage and argon pressure in discharge source. These parameters influence each other during glow discharge process. This paper presents an automatic control system for DC glow discharge plasma source. This system collects and controls discharge voltage automatically by adjusting discharge source pressure while the discharge current is constant in the glow discharge process. The design concept, circuit principle and control program of this automatic control system are described. The accuracy is improved by this automatic control system with the method of reducing the complex operations and manual control errors. This system enhances the control accuracy of glow discharge voltage, and reduces the time to reach discharge voltage stability. The glow discharge voltage stability test results with automatic control system are provided as well, the accuracy with automatic control system is better than 1% FS which is improved from 4% FS by manual control. Time to reach discharge voltage stability has been shortened to within 30 s by automatic control from more than 90 s by manual control. Standard samples like middle-low alloy steel and tin bronze have been tested by this automatic control system. The concentration analysis precision has been significantly improved. The RSDs of all the test result are better than 3.5%. In middle-low alloy steel standard sample, the RSD range of concentration test result of Ti, Co and Mn elements is reduced from 3.0%-4.3% by manual control to 1.7%-2.4% by automatic control, and that for S and Mo is also reduced from 5.2%-5.9% to 3.3%-3.5%. In tin bronze standard sample, the RSD range of Sn, Zn and Al elements is reduced from 2.6%-4.4% to 1.0%-2.4%, and that for Si, Ni and Fe is reduced from 6.6%-13.9% to 2.6%-3.5%. The test data is also shown in this paper.
2014-06-01
TECHNICAL REPORT 2077 June 2014 Modeling Tool to Quantify Metal Sources in Stormwater Discharges at Naval Facilities (NESDI Project 455... Stormwater Discharges at Naval Facilities (NESDI Project 455) Final Report and Guidance C. Katz K. Sorensen E. Arias SSC Pacific R. Pitt L. Talebi...demonstration/validation project to assess the use of the urban stormwater model Windows Source Loading and Management Model (WinSLAMM) to characterize
Young's double-slit interference with two-color biphotons.
Zhang, De-Jian; Wu, Shuang; Li, Hong-Guo; Wang, Hai-Bo; Xiong, Jun; Wang, Kaige
2017-12-12
In classical optics, Young's double-slit experiment with colored coherent light gives rise to individual interference fringes for each light frequency, referring to single-photon interference. However, two-photon double-slit interference has been widely studied only for wavelength-degenerate biphoton, known as subwavelength quantum lithography. In this work, we report double-slit interference experiments with two-color biphoton. Different from the degenerate case, the experimental results depend on the measurement methods. From a two-axis coincidence measurement pattern we can extract complete interference information about two colors. The conceptual model provides an intuitional picture of the in-phase and out-of-phase photon correlations and a complete quantum understanding about the which-path information of two colored photons.
NASA Astrophysics Data System (ADS)
Li, Xiaowei; Tan, Qiaofeng; Bai, Benfeng; Jin, Guofan
2011-06-01
We demonstrate experimentally the directional excitation of surface plasmon polaritons (SPPs) on a metal film by a subwavelength double slit under backside illumination, based on the interference of SPPs generated by the two slits. By varying the incident angle, the SPPs can be tunably directed into two opposite propagating directions with a predetermined splitting ratio. Under certain incident angle, unidirectional SPP excitation can be achieved. This compact directional SPP coupler is potentially useful for many on-chip applications. As an example, we show the integration of the double-slit couplers with SPP Bragg mirrors, which can effectively realize selective coupling of SPPs into different ports in an integrated plasmonic chip.
Linear wide angle sun sensor for spinning satellites
NASA Astrophysics Data System (ADS)
Philip, M. P.; Kalakrishnan, B.; Jain, Y. K.
1983-08-01
A concept is developed which overcomes the defects of the nonlinearity of response and limitation in range exhibited by the V-slit, N-slit, and crossed slit sun sensors normally used for sun elevation angle measurements on spinning spacecraft. Two versions of sensors based on this concept which give a linear output and have a range of nearly + or - 90 deg of elevation angle are examined. Results are presented for the application of the twin slit version of the sun sensor in the three Indian satellites, Rohini, Apple, and Bhaskara II, which was successfully used for spin rate control and spin axis orientation control corrections as well as for sun elevation angle and spin period measurements.
Ade, P. A. R.; Aghanim, N.; Arnaud, M.; ...
2016-02-09
In this paper, we present the results of approximately three years of observations of Planck Sunyaev-Zeldovich (SZ) sources with telescopes at the Canary Islands observatories as part of the general optical follow-up programme undertaken by the Planck Collaboration. In total, 78 SZ sources are discussed. Deep-imaging observations were obtained for most of these sources; spectroscopic observations in either in long-slit or multi-object modes were obtained for many. We effectively used 37.5 clear nights. We found optical counterparts for 73 of the 78 candidates. This sample includes 53 spectroscopic redshift determinations, 20 of them obtained with a multi-object spectroscopic mode. Finally,more » the sample contains new redshifts for 27 Planck clusters that were not included in the first Planck SZ source catalogue (PSZ1).« less
Wave-particle dualism and complementarity unraveled by a different mode
Menzel, Ralf; Puhlmann, Dirk; Heuer, Axel; Schleich, Wolfgang P.
2012-01-01
The precise knowledge of one of two complementary experimental outcomes prevents us from obtaining complete information about the other one. This formulation of Niels Bohr’s principle of complementarity when applied to the paradigm of wave-particle dualism—that is, to Young’s double-slit experiment—implies that the information about the slit through which a quantum particle has passed erases interference. In the present paper we report a double-slit experiment using two photons created by spontaneous parametric down-conversion where we observe interference in the signal photon despite the fact that we have located it in one of the slits due to its entanglement with the idler photon. This surprising aspect of complementarity comes to light by our special choice of the TEM01 pump mode. According to quantum field theory the signal photon is then in a coherent superposition of two distinct wave vectors giving rise to interference fringes analogous to two mechanical slits. PMID:22628561
Rigorous theory of the diffraction of Gaussian beams by finite gratings: TM polarization.
Mata-Mendez, O; Avendaño, J; Chavez-Rivas, F
2006-08-01
Diffraction of TM-polarized Gaussian beams by N equally spaced slits (finite grating) in a planar perfectly conducting thick screen is treated. We extend to the TM polarization case the results of a previous paper where the TE polarization was considered. The far-field diffraction patterns, the transmission coefficient tau, and the normally diffracted energy E as a function of several optogeometrical parameters are analyzed within the so-called vectorial region. The existence of constant-intensity angles in the far field when the incident beam wave is scanned along the N slits is shown. In addition, the property E=Ntau/lambda, valid in the scalar region, is extended to the TM polarization case in the vectorial region, lambda being the wavelength. The coupling between slits is analyzed, giving an oscillating amplitude-decreasing function as the separation between slits increases, where the period for these oscillations is the wavelength lambda. Finally, the extraordinary optical transmission phenomena that appear when the wavelength is larger than the slit width (subwavelength regime) are analyzed.
Collimation testing using slit Fresnel diffraction
NASA Astrophysics Data System (ADS)
Luo, Xiaohe; Hui, Mei; Wang, Shanshan; Hou, Yinlong; Zhou, Siyu; Zhu, Qiudong
2018-03-01
A simple collimation testing method based on slit Fresnel diffraction is proposed. The method needs only a CMOS and a slit with no requirement in dimensional accuracy. The light beam to be tested diffracts across the slit and forms a Fresnel diffraction pattern received by CMOS. After analysis, the defocusing amount and the distance between the primary peak point and secondary peak point of diffraction pattern fulfill an expression relationship and then the defocusing amount can be deduced from the expression. The method is applied to both the coherent beam and partially coherent beam, and these two beams are emitted from a laser and light-emitting diode (LED) with a spectrum width of about 50 nm in this paper. Simulations show that the wide spectrum of LED has the effect of smooth filtering to provide higher accuracy. Experiments show that the LED with a spectrum width of about 50 nm has a lower limitation error than the laser and can achieve up to 58.1601 μm with focal length 200 mm and slit width 15 mm.
Electro-optical design of a long slit streak tube
NASA Astrophysics Data System (ADS)
Tian, Liping; Tian, Jinshou; Wen, Wenlong; Chen, Ping; Wang, Xing; Hui, Dandan; Wang, Junfeng
2017-11-01
A small size and long slit streak tube with high spatial resolution was designed and optimized. Curved photocathode and screen were adopted to increase the photocathode working area and spatial resolution. High physical temporal resolution obtained by using a slit accelerating electrode. Deflection sensitivity of the streak tube was improved by adopting two-folded deflection plates. The simulations indicate that the photocathode effective working area can reach 30mm × 5mm. The static spatial resolution is higher than 40lp/mm and 12lp/mm along scanning and slit directions respectively while the physical temporal resolution is higher than 60ps. The magnification is 0.75 and 0.77 in scanning and slit directions. And also, the deflection sensitivity is as high as 37mm/kV. The external dimension of the streak tube are only ∅74mm×231mm. Thus, it can be applied to laser imaging radar system for large field of view and high range precision detection.
Caminati, Marco; Dama, Annarita; Schiappoli, Michele; Senna, Gianenrico
2013-10-01
Over the last 20 years, studies and clinical trials have demonstrated efficacy, safety and cost-effectiveness of sublingual immunotherapy (SLIT) for respiratory allergic diseases. Nevertheless, it seems to be mostly used as a second-line therapeutic option, and adherence to treatment is not always optimal. Selective literature research was done in Medline and PubMed, including guidelines, position papers and Cochrane meta-analyses concerning SLIT in adult patients. The most recent reviews confirm SLIT as viable and efficacious treatment especially for allergic rhinitis, even if the optimal dosage, duration, schedule are not clearly established for most of the products. Despite an optimal safety profile, tolerability and patient-reported outcomes concerning SLIT have received poor attention until now. Recently, new tools have been specifically developed in order to investigate these aspects. Regular assessment of tolerability profile and SLIT-related patient-reported outcomes will allow balancing efficacy with tolerability and all the other patient-related variables that may affect treatment effectiveness beyond its efficacy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mayoral-Astorga, L. A.; Gaspar-Armenta, J. A.; Ramos-Mendieta, F.
2016-04-15
We have studied numerically the diffraction of a surface plasmon polariton (SPP) when it encounters a wide multi-wavelength slit in conducting films. As a jump process a SPP is excited beyond the slit by wave scattering at the second slit edge. The exciting radiation is produced when the incident SPP collapses at the first slit edge. We have found that the transmitted SPP supports inherent and unavoidable interference with grazing scattered radiation; the spatial modulation extends to the fields in the diffraction region where a series of low intensity spots arises. We demonstrate that the SPP generated on the secondmore » slab depends on the frequency but not on the wave vector of the collapsed SPP; a SPP is transmitted even when the two metals forming the slit are different. The numerical results were obtained using the Finite Difference Time Domain (FDTD) method with a grid size λ/100.« less
MiR-218 Inhibits Invasion and Metastasis of Gastric Cancer by Targeting the Robo1 Receptor
Wu, Kaichun; Liu, Jie; Sun, Shiren; Guo, Xuegang; Wang, Biaoluo; Gang, Yi; Zhang, Yongguo; Li, Quanjiang; Qiao, Taidong; Zhao, Qingchuan; Nie, Yongzhan; Fan, Daiming
2010-01-01
MicroRNAs play key roles in tumor metastasis. Here, we describe the regulation and function of miR-218 in gastric cancer (GC) metastasis. miR-218 expression is decreased along with the expression of one of its host genes, Slit3 in metastatic GC. However, Robo1, one of several Slit receptors, is negatively regulated by miR-218, thus establishing a negative feedback loop. Decreased miR-218 levels eliminate Robo1 repression, which activates the Slit-Robo1 pathway through the interaction between Robo1 and Slit2, thus triggering tumor metastasis. The restoration of miR-218 suppresses Robo1 expression and inhibits tumor cell invasion and metastasis in vitro and in vivo. Taken together, our results describe a Slit-miR-218-Robo1 regulatory circuit whose disruption may contribute to GC metastasis. Targeting miR-218 may provide a strategy for blocking tumor metastasis. PMID:20300657
Oie, Yoshinori; Nishida, Kohji
2017-11-01
Detection of the exact area of corneal neovascularization using slit-lamp photography is often difficult. Thus, we evaluated corneal neovascularization in patients with limbal stem cell deficiency using optical coherence tomography angiography (OCTA). Five patients with 5 eyes showing partial or total limbal stem cell deficiency were enrolled. Three eyes had severe corneal scarring. Five 6- × 6-mm images (frontal, upper, lower, nasal, and temporal) were obtained by OCTA. Slit-lamp photography was performed for all patients on the same day. OCTA has 2 advantages over slit-lamp photography for clear demonstration of corneal neovascularization. First, OCTA can show neovascularization in cases with severe corneal opacification. Second, OCTA can detect not only large vessels but also small vessels that cannot be seen by slit-lamp photography. OCTA is a powerful tool for objective evaluation of vascularization in the anterior and posterior segments of the eye. We have demonstrated that OCTA can visualize corneal neovascularization in patients with corneal diseases more clearly than slit-lamp photography.
NASA Astrophysics Data System (ADS)
Tian, Yuan; Decker, Trevor K.; McClellan, Joshua S.; Bennett, Linsey; Li, Ailin; De la Cruz, Abraham; Andrews, Derek; Lammert, Stephen A.; Hawkins, Aaron R.; Austin, Daniel E.
2018-02-01
We present a new two-plate linear ion trap mass spectrometer that overcomes both performance-based and miniaturization-related issues with prior designs. Borosilicate glass substrates are patterned with aluminum electrodes on one side and wire-bonded to printed circuit boards. Ions are trapped in the space between two such plates. Tapered ejection slits in each glass plate eliminate issues with charge build-up within the ejection slit and with blocking of ions that are ejected at off-nominal angles. The tapered slit allows miniaturization of the trap features (electrode size, slit width) needed for further reduction of trap size while allowing the use of substrates that are still thick enough to provide ruggedness during handling, assembly, and in-field applications. Plate spacing was optimized during operation using a motorized translation stage. A scan rate of 2300 Th/s with a sample mixture of toluene and deuterated toluene (D8) and xylenes (a mixture of o-, m-, p-) showed narrowest peak widths of 0.33 Th (FWHM).
Ion energy spread and current measurements of the rf-driven multicusp ion source
NASA Astrophysics Data System (ADS)
Lee, Y.; Gough, R. A.; Kunkel, W. B.; Leung, K. N.; Perkins, L. T.; Pickard, D. S.; Sun, L.; Vujic, J.; Williams, M. D.; Wutte, D.
1997-03-01
Axial energy spread and useful beam current of positive ion beams have been carried out using a radio frequency (rf)-driven multicusp ion source. Operating the source with a 13.56 MHz induction discharge, the axial energy spread is found to be approximately 3.2 eV. The extractable beam current of the rf-driven source is found to be comparable to that of filament-discharge sources. With a 0.6 mm diameter extraction aperture, a positive hydrogen ion beam current density of 80 mA/cm2 can be obtained at a rf input power of 2.5 kW. The expected source lifetime is much longer than that of filament discharges.
Cao, Qianzhong; Lin, Yiquan; Xie, Zhubin; Shen, Weihua; Chen, Ying; Gan, Xiaoliang; Liu, Yizhi
2017-06-01
Pediatric ophthalmic examinations can be conducted under sedation either by chloral hydrate or by dexmedetomidine. The objective was to compare the success rates and quality of ophthalmic examination of children sedated by intranasal dexmedetomidine vs oral chloral hydrate. One hundred and forty-one children aged from 3 to 36 months (5-15 kg) scheduled to ophthalmic examinations were randomly sedated by either intranasal dexmedetomidine (2 μg·kg -1 , n = 71) or oral chloral hydrate (80 mg·kg -1 , n = 70). The primary endpoint was successful sedation to complete the examinations including slit-lamp photography, tonometry, anterior segment analysis, and refractive error inspection. The secondary endpoints included quality of eye position, intraocular pressure, onset time, duration of examination, recovery time, discharge time, any side effects during examination, and within 48 h after discharge. Sixty-one children were sedated by dexmedetomidine with a success rate of 85.9%, which is significantly higher than that by chloral hydrate (64.3%) [OR 3.39, 95% CI: 1.48-7.76, P = 0.003]. Furthermore, children in the dexmedetomidine group displayed better eye position in anterior segment analysis than in chloral hydrate group median difference. All children displayed stable hemodynamics and none suffered hypoxemia in both groups. Oral chloral hydrate induced higher percentages of vomiting and altered bowel habit after discharge than dexmedetomidine. Intranasal dexmedetomidine provides more successful sedation and better quality of ophthalmic examinations than oral chloral hydrate for small children. © 2017 John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mihailescu, Lucian
This disclosure provides systems, methods, and apparatus related to ion beam therapy. In one aspect, a system includes a position sensitive detector and a collimator. The position sensitive detector configured to detect gamma rays generated by an ion beam interacting with a target. The collimator is positioned between the target and the position sensitive detector. The collimator includes a plurality of knife-edge slits, with a first knife-edge slit intersecting with a second knife-edge slit.
Quantum games with a multi-slit electron diffraction set-up
NASA Astrophysics Data System (ADS)
Iqbal, A.
2003-05-01
A set-up is proposed to play a quantum version of the famous bimatrix game of Prisoners' Dilemma. Multi-slit electron diffraction with each player's pure strategy consisting of opening one of the two slits at his/her disposal are essential features of the set-up. Instead of entanglement the association of waves with travelling material objects is suggested as another resource to play quantum games.
Resonant Slit-type Probe with Rounded Matching Structure for Terahertz Imaging
NASA Astrophysics Data System (ADS)
Kim, Geun-Ju; Kim, Jung-Il; Kim, Sanghoon; Lee, Jeong-Hun; Jeon, Tae-In
2018-05-01
We propose a resonant slit-type probe with a rounded matching structure in the inner corner of the probe slit, for high-resolution terahertz (THz) imaging. The proposed probe can achieve high coupling efficiency and maintain a stable resonant frequency in spite of the increase in slit thickness. The THz signal measured by the proposed probe was 1.7 times more sensitive than that by a right angle structure probe when a 50 μm diameter metal ball was located 100 um away from the slits. The resonant frequency and return loss |S11| measurements of the prototype resonant probe using a vector network analyzer (VNA) were in good agreement with a simulation results. We achieved a spatial resolution of 100 μm with a slit height of 140 μm. Also, to determine the potential of the proposed probe in the THz applications, we measured THz images according to the thickness of covering flour and the distance between the probe and the flour for the foreign objects in the flour. The proposed probe detected a metal wire with a diameter of 70 μm beneath 1.5 mm of flour at a distance between flour and probe of 1 mm. Consequently, we confirmed that the proposed probe could potentially be applied as a new THz probe.
A simple method for panretinal imaging with the slit lamp.
Gellrich, Marcus-Matthias
2016-12-01
Slit lamp biomicroscopy of the retina with a convex lens is a key procedure in clinical practice. The methods presented enable ophthalmologists to adequately image large and peripheral parts of the fundus using a video-slit lamp and freely available stitching software. A routine examination of the fundus with a slit lamp and a +90 D lens is recorded on a video film. Later, sufficiently sharp still images are identified on the video sequence. These still images are imported into a freely available image-processing program (Hugin, for stitching mosaics together digitally) and corresponding points are marked on adjacent still images with some overlap. Using the digital stitching program Hugin panoramic overviews of the retina can be built which can extend to the equator. This allows to image diseases involving the whole retina or its periphery by performing a structured fundus examination with a video-slit lamp. Similar images with a video-slit lamp based on a fundus examination through a hand-held non-contact lens have not been demonstrated before. The methods presented enable those ophthalmologists without high-end imaging equipment to monitor pathological fundus findings. The suggested procedure might even be interesting for retinological departments if peripheral findings are to be documented which might be difficult with fundus cameras.
Imaging slit-coupled surface plasmon polaritons using conventional optical microscopy.
Mehfuz, R; Chowdhury, F A; Chau, K J
2012-05-07
We develop a technique that now enables surface plasmon polaritons (SPPs) coupled by nano-patterned slits in a metal film to be detected using conventional optical microscopy with standard objective lenses. The crux of this method is an ultra-thin polymer layer on the metal surface, whose thickness can be varied over a nanoscale range to enable controllable tuning of the SPP momentum. At an optimal layer thickness for which the SPP momentum matches the momentum of light emerging from the slit, the SPP coupling efficiency is enhanced about six times relative to that without the layer. The enhanced efficiency results in distinctive and bright plasmonic signatures near the slit visible by naked eye under an optical microscope. We demonstrate how this capability can be used for parallel measurement through a simple experiment in which the SPP propagation distance is extracted from a single microscope image of an illuminated array of nano-patterned slits on a metal surface. We also use optical microscopy to image the focal region of a plasmonic lens and obtain results consistent with a previously-reported results using near-field optical microscopy. Measurement of SPPs near a nano-slit using conventional and widely-available optical microscopy is an important step towards making nano-plasmonic device technology highly accessible and easy-to-use.
Brusseau, M. L.; Hatton, J.; DiGuiseppi, W.
2011-01-01
The long-term impact of source-zone remediation efforts was assessed for a large site contaminated by trichloroethene. The impact of the remediation efforts (soil vapor extraction and in-situ chemical oxidation) was assessed through analysis of plume-scale contaminant mass discharge, which was measured using a high-resolution data set obtained from 23 years of operation of a large pump-and-treat system. The initial contaminant mass discharge peaked at approximately 7 kg/d, and then declined to approximately 2 kg/d. This latter value was sustained for several years prior to the initiation of source-zone remediation efforts. The contaminant mass discharge in 2010, measured several years after completion of the two source-zone remediation actions, was approximately 0.2 kg/d, which is ten times lower than the value prior to source-zone remediation. The time-continuous contaminant mass discharge data can be used to evaluate the impact of the source-zone remediation efforts on reducing the time required to operate the pump-and-treat system, and to estimate the cost savings associated with the decreased operational period. While significant reductions have been achieved, it is evident that the remediation efforts have not completely eliminated contaminant mass discharge and associated risk. Remaining contaminant mass contributing to the current mass discharge is hypothesized to comprise poorly-accessible mass in the source zones, as well as aqueous (and sorbed) mass present in the extensive lower-permeability units located within and adjacent to the contaminant plume. The fate of these sources is an issue of critical import to the remediation of chlorinated-solvent contaminated sites, and development of methods to address these sources will be required to achieve successful long-term management of such sites and to ultimately transition them to closure. PMID:22115080
Variable-Size Bead Layer as Standard Reference for Endothelial Microscopes.
Tufo, Simona; Prazzoli, Erica; Ferraro, Lorenzo; Cozza, Federica; Borghesi, Alessandro; Tavazzi, Silvia
2017-02-01
For morphometric analysis of the cell mosaic of corneal endothelium, checking accuracy and precision of instrumentation is a key step. In this study, a standard reference sample is proposed, developed to reproduce the cornea with its shape and the endothelium with its intrinsic variability in the cell size. A polystyrene bead layer (representing the endothelium) was deposited on a lens (representing the cornea). Bead diameters were 20, 25, and 30 μm (fractions in number 55%, 30%, and 15%, respectively). Bead density and hexagonality were simulated to obtain the expected true values and measured using a slit-lamp endothelial microscope applied to 1) a Takagi 700GL slit lamp at 40× magnification (recommended standard setup) and 2) a Takagi 2ZL slit lamp at 25× magnification. The simulation provided the expected bead density 2001 mm and hexagonality 47%. At 40×, density and hexagonality were measured to be 2009 mm (SD 93 mm) and 45% (SD 3%). At 25× on a different slit lamp, the comparison between measured and expected densities provided the factor 1.526 to resize the image and to use the current algorithms of the slit-lamp endothelial microscope for cell recognition. A variable-size polystyrene bead layer on a lens is proposed as a standard sample mimicking the real shape of the cornea and the variability of cell size and cell arrangement of corneal endothelium. The sample is suggested to evaluate accuracy and precision of cell density and hexagonality obtained by different endothelial microscopes, including a slit-lamp endothelial microscope applied to different slit lamps, also at different magnifications.
Concept Study Report: Extreme-Ultraviolet Imaging Spectrometer Solar-B
NASA Technical Reports Server (NTRS)
Doschek, George, A.; Brown, Charles M.; Davila, Joseph M.; Dere, Kenneth P.; Korendyke, Clarence M.; Mariska, John T.; Seely, John F.
1999-01-01
We propose a next generation Extreme-ultraviolet Imaging Spectrometer (EIS) that for the first time combines high spectral, spatial, and temporal resolution in a single solar spectroscopic instrument. The instrument consists of a multilayer-coated off-axis telescope mirror and a multilayer-coated grating spectrometer. The telescope mirror forms solar images on the spectrometer entrance slit assembly. The spectrometer forms stigmatic spectra of the solar region located at the slit. This region is selected by the articulated telescope mirror. Monochromatic images are obtained either by rastering the solar region across a narrow entrance slit, or by using a very wide slit (called a slot) in place of the slit. Monochromatic images of the region centered on the slot are obtained in a single exposure. Half of each optic is coated to maximize reflectance at 195 Angstroms; the other half to maximize reflectance at 270 Angstroms. The two Extreme Ultraviolet (EUV) wavelength bands have been selected to maximize spectral and dynamical and plasma diagnostic capabilities. Spectral lines are observed that are formed over a temperature range from about 0.1 MK to about 20 MK. The main EIS instrument characteristics are: wavelength bands - 180 to 204 Angstroms; 250 to 290 Angstroms; spectral resolution - 0.0223 Angstroms/pixel (34.3km/s at 195 Angstroms and 23.6 km/s at 284 Angstroms); slit dimensions - 4 slits, two currently specified dimensions are 1" x 1024" and 50" x 1024" (the slot); largest spatial field of view in a single exposure - 50" x 1024"; highest time resolution for active region velocity studies - 4.4 s.
Large area, surface discharge pumped, vacuum ultraviolet light source
Sze, R.C.; Quigley, G.P.
1996-12-17
Large area, surface discharge pumped, vacuum ultraviolet (VUV) light source is disclosed. A contamination-free VUV light source having a 225 cm{sup 2} emission area in the 240-340 nm region of the electromagnetic spectrum with an average output power in this band of about 2 J/cm{sup 2} at a wall-plug efficiency of approximately 5% is described. Only ceramics and metal parts are employed in this surface discharge source. Because of the contamination-free, high photon energy and flux, and short pulse characteristics of the source, it is suitable for semiconductor and flat panel display material processing. 3 figs.
Takahashi, Toshiaki; Friedmacher, Florian; Zimmer, Julia; Puri, Prem
2017-06-01
Congenital diaphragmatic hernia (CDH) has been attributed to various developmental abnormalities of the underlying tissue components. N-deacetylase-N-sulfotransferase-1 (Ndst1) is a strongly expressed biosynthetic enzyme in endothelial cells, which has recently been identified as an important factor during diaphragmatic vascularization. Loss of endothelial Ndst1 has been demonstrated to cause angiogenic defects in the developing diaphragm and disrupt normal diaphragmatic development. Furthermore, deficiency of Ndst1 diminishes the expression of slit homolog 3 (Slit3), a known CDH-related gene that has been associated with reduced vascular density and muscle defects in the diaphragm of Slit3 -/- mice. We hypothesized that expression of Ndst1 and Slit3 is decreased in the diaphragmatic vasculature of fetal rats with nitrofen-induced CDH. Time-mated rats received either nitrofen or vehicle on gestational day 9 (D9). Fetal diaphragms were microdissected on D13, D15 and D18, and divided into control and nitrofen-exposed specimens. Gene expression levels of Ndst1 and Slit3 were assessed using qRT-PCR. Immunofluorescence-double-staining for Ndst1 and Slit3 was performed to evaluate protein expression and localization. Relative mRNA expression of Ndst1 and Slit3 was significantly decreased in pleuroperitoneal folds (D13), developing diaphragms (D15) and fully muscularized diaphragms (D18) of nitrofen-exposed fetuses compared to controls. Confocal-laser-scanning-microscopy revealed markedly diminished Ndst1 and Slit3 expression in endothelial cells within the diaphragmatic vasculature on D13, D15 and D18 compared to controls. Down-regulation of Ndst1 signaling in the developing diaphragm may impair endothelial cell migration and angiogenesis, thus leading to defective diaphragmatic vascular development and CDH. Ib. Copyright © 2017 Elsevier Inc. All rights reserved.
High-resolution spectroscopy of jet-cooled CH5+: Progress
NASA Astrophysics Data System (ADS)
Savage, C.; Dong, F.; Nesbitt, D. J.
2015-01-01
Protonated methane (CH5+) is thought to be a highly abundant molecular ion in interstellar medium, as well as a potentially bright μwave- mm wave emitter that could serve as a tracer for methane. This paper describes progress and first successful efforts to obtain a high resolution, supersonically cooled spectrum of CH5+ in the 2900-3100 cm-1 region, formed in a slit supersonic discharge at low jet temperatures and with sub-Doppler resolution. Short term precision in frequency measurement (< 5 MHz on an hour time scale) is obtained from a thermally controlled optical transfer cavity servoloop locked onto a frequency stabilized HeNe laser. Long term precision (< 20 MHz day-to-day) due to pressure, temperature and humidity dependent index of refraction effects in the optical transfer cavity is also present and discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Onai, M., E-mail: onai@ppl.appi.keio.ac.jp; Fujita, S.; Hatayama, A.
2016-02-15
Recently, a filament driven multi-cusp negative ion source has been developed for proton cyclotrons in medical applications. In this study, numerical modeling of the filament arc-discharge source plasma has been done with kinetic modeling of electrons in the ion source plasmas by the multi-cusp arc-discharge code and zero dimensional rate equations for hydrogen molecules and negative ions. In this paper, main focus is placed on the effects of the arc-discharge power on the electron energy distribution function and the resultant H{sup −} production. The modelling results reasonably explains the dependence of the H{sup −} extraction current on the arc-discharge powermore » in the experiments.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wickliff, D.S.; Solomon, D.K.; Farrow, N.D.
Solid Waste Storage Area (SWSA) 5 is known to be a significant source of contaminants, especially tritium ({sup 3}H), to the White Oak Creek (WOC) watershed. For example, Solomon et al. (1991) estimated the total {sup 3}H discharge in Melton Branch (most of which originates in SWSA 5) for the 1988 water year to be 1210 Ci. A critical issue for making decisions concerning remedial actions at SWSA 5 is knowing whether the annual contaminant discharge is increasing or decreasing. Because (1) the magnitude of the annual contaminant discharge is highly correlated to the amount of annual precipitation (Solomon etmore » al., 1991) and (2) a significant lag may exist between the time of peak contaminant release from primary sources (i.e., waste trenches) and the time of peak discharge into streams, short-term stream monitoring by itself is not sufficient for predicting future contaminant discharges. In this study we use {sup 3}H to examine the link between contaminant release from primary waste sources and contaminant discharge into streams. By understanding and quantifying subsurface transport processes, realistic predictions of future contaminant discharge, along with an evaluation of the effectiveness of remedial action alternatives, will be possible. The objectives of this study are (1) to characterize the subsurface movement of contaminants (primarily {sup 3}H) with an emphasis on the effects of matrix diffusion; (2) to determine the relative strength of primary vs secondary sources; and (3) to establish a methodology capable of determining whether the {sup 3}H discharge from SWSA 5 to streams is increasing or decreasing.« less
Preliminary investigation of processes that affect source term identification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wickliff, D.S.; Solomon, D.K.; Farrow, N.D.
Solid Waste Storage Area (SWSA) 5 is known to be a significant source of contaminants, especially tritium ({sup 3}H), to the White Oak Creek (WOC) watershed. For example, Solomon et al. (1991) estimated the total {sup 3}H discharge in Melton Branch (most of which originates in SWSA 5) for the 1988 water year to be 1210 Ci. A critical issue for making decisions concerning remedial actions at SWSA 5 is knowing whether the annual contaminant discharge is increasing or decreasing. Because (1) the magnitude of the annual contaminant discharge is highly correlated to the amount of annual precipitation (Solomon etmore » al., 1991) and (2) a significant lag may exist between the time of peak contaminant release from primary sources (i.e., waste trenches) and the time of peak discharge into streams, short-term stream monitoring by itself is not sufficient for predicting future contaminant discharges. In this study we use {sup 3}H to examine the link between contaminant release from primary waste sources and contaminant discharge into streams. By understanding and quantifying subsurface transport processes, realistic predictions of future contaminant discharge, along with an evaluation of the effectiveness of remedial action alternatives, will be possible. The objectives of this study are (1) to characterize the subsurface movement of contaminants (primarily {sup 3}H) with an emphasis on the effects of matrix diffusion; (2) to determine the relative strength of primary vs secondary sources; and (3) to establish a methodology capable of determining whether the {sup 3}H discharge from SWSA 5 to streams is increasing or decreasing.« less
Measurement-induced decoherence and information in double-slit interference.
Kincaid, Joshua; McLelland, Kyle; Zwolak, Michael
2016-07-01
The double slit experiment provides a classic example of both interference and the effect of observation in quantum physics. When particles are sent individually through a pair of slits, a wave-like interference pattern develops, but no such interference is found when one observes which "path" the particles take. We present a model of interference, dephasing, and measurement-induced decoherence in a one-dimensional version of the double-slit experiment. Using this model, we demonstrate how the loss of interference in the system is correlated with the information gain by the measuring apparatus/observer. In doing so, we give a modern account of measurement in this paradigmatic example of quantum physics that is accessible to students taking quantum mechanics at the graduate or senior undergraduate levels.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li Xiaowei; Tsinghua-Foxconn Nanotechnology Research Center, Tsinghua University, Beijing 100084; Tan Qiaofeng
2011-06-20
We demonstrate experimentally the directional excitation of surface plasmon polaritons (SPPs) on a metal film by a subwavelength double slit under backside illumination, based on the interference of SPPs generated by the two slits. By varying the incident angle, the SPPs can be tunably directed into two opposite propagating directions with a predetermined splitting ratio. Under certain incident angle, unidirectional SPP excitation can be achieved. This compact directional SPP coupler is potentially useful for many on-chip applications. As an example, we show the integration of the double-slit couplers with SPP Bragg mirrors, which can effectively realize selective coupling of SPPsmore » into different ports in an integrated plasmonic chip.« less
40 CFR 60.45Da - Standard for mercury (Hg).
Code of Federal Regulations, 2011 CFR
2011-07-01
... to the provisions of this subpart shall cause to be discharged into the atmosphere from any affected... must not discharge into the atmosphere any gases from a new affected source that contain Hg in excess... discharge into the atmosphere any gases from a new affected source that contain Hg in excess of 66 × 10− 6...
Slit-scanning differential x-ray phase-contrast mammography: proof-of-concept experimental studies.
Koehler, Thomas; Daerr, Heiner; Martens, Gerhard; Kuhn, Norbert; Löscher, Stefan; van Stevendaal, Udo; Roessl, Ewald
2015-04-01
The purpose of this work is to investigate the feasibility of grating-based, differential phase-contrast, full-field digital mammography (FFDM) in terms of the requirements for field-of-view (FOV), mechanical stability, and scan time. A rigid, actuator-free Talbot interferometric unit was designed and integrated into a state-of-the-art x-ray slit-scanning mammography system, namely, the Philips MicroDose L30 FFDM system. A dedicated phase-acquisition and phase retrieval method was developed and implemented that exploits the redundancy of the data acquisition inherent to the slit-scanning approach to image generation of the system. No modifications to the scan arm motion control were implemented. The authors achieve a FOV of 160 × 196 mm consisting of two disjoint areas measuring 77 × 196 mm with a gap of 6 mm between them. Typical scanning times vary between 10 and 15 s and dose levels are lower than typical FFDM doses for conventional scans with identical acquisition parameters due to the presence of the source-grating G0. Only minor to moderate artifacts are observed in the three reconstructed images, indicating that mechanical vibrations induced by other system components do not prevent the use of the platform for phase contrast imaging. To the best of our knowledge, this is the first attempt to integrate x-ray gratings hardware into a clinical mammography unit. The results demonstrate that a scanning differential phase contrast FFDM system that meets the requirements of FOV, stability, scan time, and dose can be build.
40 CFR 406.16 - Pretreatment standards for new sources.
Code of Federal Regulations, 2011 CFR
2011-07-01
... GUIDELINES AND STANDARDS GRAIN MILLS POINT SOURCE CATEGORY Corn Wet Milling Subcategory § 406.16 Pretreatment... new corn wet milling source to be discharged to the POTW (gallons per one hour for flow and pounds per... corn wet milling source to be discharged to POTW. S = existing peak load of POTW. K = 2. When the ratio...
Discharge source with gas curtain for protecting optics from particles
Fornaciari, Neal R.; Kanouff, Michael P.
2004-03-30
A gas curtain device is employed to deflect debris that is generated by an extreme ultraviolet and soft x-ray radiation discharge source such as an electric discharge plasma source. The gas curtain device projects a stream of gas over the path of the radiation to deflect debris particles into a direction that is different from that of the path of the radiation. The gas curtain can be employed to prevent debris accumulation on the optics used in photolithography.
Matthieu, D.E.; Carroll, K.C.; Mainhagu, J.; Morrison, C.; McMillan, A.; Russo, A.; Plaschke, M.
2013-01-01
The objective of this study was to characterize the temporal behavior of contaminant mass discharge, and the relationship between reductions in contaminant mass discharge and reductions in contaminant mass, for a very heterogeneous, highly contaminated source-zone field site. Trichloroethene is the primary contaminant of concern, and several lines of evidence indicate the presence of organic liquid in the subsurface. The site is undergoing groundwater extraction for source control, and contaminant mass discharge has been monitored since system startup. The results show a significant reduction in contaminant mass discharge with time, decreasing from approximately 1 to 0.15 kg/d. Two methods were used to estimate the mass of contaminant present in the source area at the initiation of the remediation project. One was based on a comparison of two sets of core data, collected 3.5 years apart, which suggests that a significant (~80%) reduction in aggregate sediment-phase TCE concentrations occurred between sampling events. The second method was based on fitting the temporal contaminant mass discharge data with a simple exponential source-depletion function. Relatively similar estimates, 784 and 993 kg, respectively, were obtained with the two methods. These data were used to characterize the relationship between reductions in contaminant mass discharge (CMDR) and reductions in contaminant mass (MR). The observed curvilinear relationship exhibits a reduction in contaminant mass discharge essentially immediately upon initiation of mass reduction. This behavior is consistent with a system wherein significant quantities of mass are present in hydraulically poorly accessible domains for which mass removal is influenced by rate-limited mass transfer. The results obtained from the present study are compared to those obtained from other field studies to evaluate the impact of system properties and conditions on mass-discharge and mass-removal behavior. The results indicated that factors such as domain scale, hydraulic-gradient status (induced or natural), and flushing-solution composition had insignificant impact on the CMDR-MR profiles and thus on underlying mass-removal behavior. Conversely, source-zone age, through its impact on contaminant distribution and accessibility, was implicated as a critical factor influencing the nature of the CMDR-MR relationship. PMID:23528743
Higher-Order Interference in Extensions of Quantum Theory
NASA Astrophysics Data System (ADS)
Lee, Ciarán M.; Selby, John H.
2017-01-01
Quantum interference, manifest in the two slit experiment, lies at the heart of several quantum computational speed-ups and provides a striking example of a quantum phenomenon with no classical counterpart. An intriguing feature of quantum interference arises in a variant of the standard two slit experiment, in which there are three, rather than two, slits. The interference pattern in this set-up can be written in terms of the two and one slit patterns obtained by blocking one, or more, of the slits. This is in stark contrast with the standard two slit experiment, where the interference pattern cannot be written as a sum of the one slit patterns. This was first noted by Rafael Sorkin, who raised the question of why quantum theory only exhibits irreducible interference in the two slit experiment. One approach to this problem is to compare the predictions of quantum theory to those of operationally-defined `foil' theories, in the hope of determining whether theories that do exhibit higher-order interference suffer from pathological—or at least undesirable—features. In this paper two proposed extensions of quantum theory are considered: the theory of Density Cubes proposed by Dakić, Paterek and Brukner, which has been shown to exhibit irreducible interference in the three slit set-up, and the Quartic Quantum Theory of Życzkowski. The theory of Density Cubes will be shown to provide an advantage over quantum theory in a certain computational task and to posses a well-defined mechanism which leads to the emergence of quantum theory—analogous to the emergence of classical physics from quantum theory via decoherence. Despite this, the axioms used to define Density Cubes will be shown to be insufficient to uniquely characterise the theory. In comparison, Quartic Quantum Theory is a well-defined theory and we demonstrate that it exhibits irreducible interference to all orders. This feature of Życzkowski's theory is argued not to be a genuine phenomenon, but to arise from an ambiguity in the current definition of higher-order interference in operationally-defined theories. Thus, to begin to understand why quantum theory is limited to a certain kind of interference, a new definition of higher-order interference is needed that is applicable to, and makes good operational sense in, arbitrary operationally-defined theories.
Wilczyński, Michał; Pośpiech-Zabierek, Aleksandra
2015-01-01
The accurate measurement of the anterior chamber internal diameter and depth is important in ophthalmic diagnosis and before some eye surgery procedures. The purpose of the study was to compare the white-to-white distance measurements performed using the IOL-Master and photography with internal anterior chamber diameter determined using slit lamp adapted optical coherence tomography in healthy eyes, and to compare anterior chamber depth measurements by IOL-Master and slit lamp adapted optical coherence tomography. The data were gathered prospectively from a non-randomized consecutive series of patients. The examined group consisted of 46 eyes of 39 patients. White-to-white was measured using IOL-Master and photographs of the eye were taken with a digital camera. Internal anterior chamber diameter was measured with slit-lamp adapted optical coherence tomography. Anterior chamber depth was measured using the IOL Master and slit-lamp adapted optical coherence tomography. Statistical analysis was performed using parametric tests. A Bland-Altman plot was drawn. White-to-white distance by the IOL Master was 11.8 +/- 0.40 mm, on photographs it was 11.29 +/- 0.58 mm and internal anterior chamber diameter by slit-lamp adapted optical coherence tomography was 11.34?0.54 mm. A significant difference was found between IOL-Master and slit-lamp adapted optical coherence tomography (p<0.01), as well as between IOL Master and digital photographs (p<0.01). There was no difference between SL-OCT and digital photographs (p>0.05). All measurements were correlated (Spearman p<0.001). Mean anterior chamber depth determined using the IOL-Master was 2.99 +/- 0.50 mm and by slit-lamp adapted optical coherence tomography was 2.56 +/- 0.46 mm. The difference was statistically significant (p<0.001). The correlation between the values was also statistically significant (Spearman, p<0.001). Automated measurements using IOL-Master yield constantly higher values than measurements based on direct eye visualization slit-lamp adapted optical coherence tomography and digital photographs. In order to obtain accurate measurements of the internal anterior chamber diameter and anterior chamber depth, a method involving direct visualization of intraocular structures should be used.
Assessing TCE source bioremediation by geostatistical analysis of a flux fence.
Cai, Zuansi; Wilson, Ryan D; Lerner, David N
2012-01-01
Mass discharge across transect planes is increasingly used as a metric for performance assessment of in situ groundwater remediation systems. Mass discharge estimates using concentrations measured in multilevel transects are often made by assuming a uniform flow field, and uncertainty contributions from spatial concentration and flow field variability are often overlooked. We extend our recently developed geostatistical approach to estimate mass discharge using transect data of concentration and hydraulic conductivity, so accounting for the spatial variability of both datasets. The magnitude and uncertainty of mass discharge were quantified by conditional simulation. An important benefit of the approach is that uncertainty is quantified as an integral part of the mass discharge estimate. We use this approach for performance assessment of a bioremediation experiment of a trichloroethene (TCE) source zone. Analyses of dissolved parent and daughter compounds demonstrated that the engineered bioremediation has elevated the degradation rate of TCE, resulting in a two-thirds reduction in the TCE mass discharge from the source zone. The biologically enhanced dissolution of TCE was not significant (~5%), and was less than expected. However, the discharges of the daughter products cis-1,2, dichloroethene (cDCE) and vinyl chloride (VC) increased, probably because of the rapid transformation of TCE from the source zone to the measurement transect. This suggests that enhancing the biodegradation of cDCE and VC will be crucial to successful engineered bioremediation of TCE source zones. © 2012, The Author(s). Ground Water © 2012, National Ground Water Association.
VizieR Online Data Catalog: 1H 0323+342 rest frame optical spectrum with GHAO (Leon+, 2014)
NASA Astrophysics Data System (ADS)
Leon Tavares, J.; Kotilainen, J.; Chavushyan, V.; Anorve, C.; Puerari, I.; Cruz-Gonzalez, I.; Patino-Alvarez, V.; Anton, S.; Carraminana, A.; Carrasco, L.; Guichard, J.; Karhunen, K.; Olguin-Iglesias, A.; Sanghvi, J.; Valdes, J.
2017-05-01
Within the framework of a spectrophotometric monitoring program of bright γ-ray sources (Patino-Alvarez et al. 2013, Proc. Fermi Symposium, arXiv:1303.1893), we undertook spectroscopic observations of 1H 0323+342 using the Boller & Chivens long-slit spectrograph on the 2.1 m Guillermo Haro Astrophysical Observatory (GHAO) in Sonora, Mexico. The spectra were obtained under photometric weather conditions (2012 September 17, 2013 January 9, 2013 February 7 and 11) using a slit width of 2.5 arcsec. The spectral resolution was R=15 Å and R=7 Å (FWHM) for the low-resolution and intermediate-resolution spectra, respectively. The wavelength range for the three low-resolution spectra is 3800-7100 Å, and for one intermediate-resolution spectrum the wavelength range is 4300-5900 Å. The signal-to-noise ratio (S/N) was >40 in the continuum near H{Beta}. To enable a wavelength calibration, HeAr lamp spectra were taken after each object exposure. Spectrophotometric standard stars were observed every night (at least two per night) to enable flux calibration. (1 data file).
Zhong, C; Yang, W; Li, Y; Zou, L; Deng, Z; Liu, M; Huang, X
2018-05-01
The efficacy and safety of sublingual immunotherapy (SLIT) in house dust mite-induced allergic asthma (AA) have yet to be firmly established, especially in adult patients. Our objective is to evaluate the efficacy of SLIT with Dermatophagoides farinae drops in adult patients with AA. One hundred and thirty-four adult patient data with house dust mite (HDM)-induced AA who had been treated for 2 years were collected. These patient data that we collected were divided into the SLIT group (n = 85) and control group (n = 49). All patients were treated with low to moderate dose of inhaled glucocorticoid and long-acting β2 agonists. Patients in the SLIT group were further treated with D. farinae drops. Clinical scores including the total asthma symptom score (TASS), total asthma medicine score (TAMS), asthma control test (ACT), and peak flow percentage (PEF%) were assessed before treatment and at yearly visits. The presence of adverse events (AEs) were recorded once a month. Before treatment, the PEF% in the SLIT group was significantly lower than that in the control group (p < 0.05). After 2 years, both treatments were effective in the clinical scores when compared with baseline values (all p < 0.001). Meanwhile, the SLIT group showed significantly lower TASS and TAMS (all p < 0.001) and higher ACT (p < 0.001) and PEF% (p < 0.05) when compared with the control group. No severe systemic AEs were reported. SLIT with D. farinae drops plus pharmacotherapy is more effective than routine drug treatment in adult patients with AA.
Oliphant, Huw; Kennedy, Alasdair; Comyn, Oliver; Spalton, David J; Nanavaty, Mayank A
2018-06-16
To compare slit lamp mounted cameras (SLC) versus digital compact camera (DCC) with slit-lamp adaptor when used by an inexperienced technician. In this cross sectional study, where posterior capsule opacification (PCO) was used as a comparator, patients were consented for one photograph with SLC and two with DCC (DCC1 and DCC2), with a slit-lamp adaptor. An inexperienced clinic technician, who took all the photographs and masked the images, recruited one eye of each patient. Images were graded for PCO using ECPO2000 software by two independent masked graders. Repeatability between DCC1 & DCC2 and limits-of-agreement between SLC and DCC1 mounted on slit-lamp with an adaptor were assessed. Coefficient-of-repeatability and Bland-Altmann plots were analyzed. Seventy-two patients (eyes) were recruited in the study. First 9 patients (eyes) were excluded due to unsatisfactory image quality from both the systems. Mean EPCO score for SLC was 2.28 (95% CI: 2.09 -2.45), for DCC1 was 2.28 (95% CI: 2.11-2.45), and for the DCC2 was 2.11 (95% CI: 2.11-2.45). There was no significant difference in EPCO scores between SLC Vs. DCC1 (p = 0.98) and between DCC1 and DCC 2 (p = 0.97). Coefficient of repeatability between DCC images was 0.42, and the coefficient of repeatability between DCC and SLC was 0.58. DCC on slit-lamp with an adaptor is comparable to a SLC. There is an initial learning curve, which is similar for both for an inexperienced person. This opens up the possibility for low cost anterior segment imaging in the clinical, research and teaching settings.
Slit2 Modulates the Inflammatory Phenotype of Orbit-Infiltrating Fibrocytes in Graves' Disease.
Fernando, Roshini; Grisolia, Ana Beatriz Diniz; Lu, Yan; Atkins, Stephen; Smith, Terry J
2018-06-15
Human CD34 + fibrocytes, circulating monocyte lineage progenitor cells, have recently been implicated in thyroid-associated ophthalmopathy (TAO), the ocular manifestation of Graves' disease (GD). Fibrocytes express constitutive MHC class II (MHC-2) and, surprisingly, thyroglobulin (Tg) and functional thyrotropin (TSH) receptor (TSHR). Underlying expression of these thyroid proteins is the autoimmune regulator protein (AIRE). Fibrocytes respond robustly to TSH and thyroid-stimulating Igs by generating extremely high levels of inflammatory cytokines, such as IL-6. In TAO, they appear to infiltrate the orbit, where they transition to CD34 + orbital fibroblasts (OF). There, they coexist with CD34 - OF as a mixed fibroblast population (GD-OF). In contrast to fibrocytes, GD-OF express vanishingly low levels of MHC-2, Tg, TSHR, and AIRE. Further, the amplitude of IL-6 induction by TSH in GD-OF is substantially lower. The molecular basis for this divergence between fibrocytes and CD34 + OF remains uncertain. In this article, we report that Slit2, an axon guidance glycoprotein, is constitutively expressed by the CD34 - OF subset of GD-OF. Culture conditioned medium (CM) generated by incubating with GD-OF and CD34 - OF substantially reduces levels of MHC-2, Tg, TSHR, and AIRE in fibrocytes. Expression can be restored by specifically depleting CM of Slit2. The effects of CD34 - OF CM are mimicked by recombinant human Slit2. TSH induces Slit2 levels in GD-OF by enhancing both Slit2 gene transcription and mRNA stability. These findings suggest that Slit2 represents a TSH-inducible factor within the TAO orbit that can modulate the inflammatory phenotype of CD34 + OF and therefore may determine the activity and severity of the disease. Copyright © 2018 by The American Association of Immunologists, Inc.
NASA Astrophysics Data System (ADS)
Ma, Huai-Lung; Kuo, Cheng-Hsiung
2017-05-01
Theoretical analysis on an oscillatory plane Poiseuille flow is conducted in terms of a non-dimensional ratio (η) of the channel half-width to Stokes' layer thickness. The cyclic velocity profiles, the phase shifts and the magnitudes among the driving pressure gradient, the induced wall shear stress, and the volume flux are investigated. Also, the flow physics at a different ratio η is demonstrated. In this study, the mechanism of the driving pressure gradient and the oscillating volume flux is similar to and can be employed to demonstrate the slit flow in the application of the novel vortex flow meter using a slit cylinder as a shedder. When applied to the novel vortex flow meter, the non-dimensional ratio η can be expressed as the relation of the slit width ratio (S/D), the Strouhal number, and the Reynolds number. Finally, a range of η between 0.97 < η < 20 will be suggested for the vortex flow meter at the design stage. Large values of η are employed at a high Reynolds number, and small η is used for low Reynolds number applications. In the novel vortex flow meters, a cylinder with a normal axial slit of width (S) is employed as the shedder. Due to the primary lock-on, the process of vortex shedding synchronizes with the rhythm of slit flow leading to a stable shedding frequency. The value η is well correlated by the value of ηopt obtained by experiments and shows a one-to-one correspondence to the slit ratio at each Reynolds number. Once the design value of ηopt is determined, the optimal slit ratio can be estimated for a fixed applied Reynolds number at the design stage.
Relationship between methylation and colonic inflammation in inflammatory bowel disease
Lobatón, Triana; Azuara, Daniel; Rodríguez-Moranta, Francisco; Loayza, Carolina; Sanjuan, Xavier; de Oca, Javier; Fernández-Robles, Ana; Guardiola, Jordi; Capellá, Gabriel
2014-01-01
AIM: To investigate the relationship between the methylation status in the SLIT2 and TGFB2 promoters and colonic inflammation in inflammatory bowel disease patients. METHODS: We evaluated the methylation status of 2 genes (SLIT2 and TGFB2) in 226 biopsies taken from 62 colonoscopies of 38 patients (29 ulcerative colitis and 9 Crohn’s colitis) using methylation-specific melting curve analysis. The relationships between methylation status and clinical, biological, endoscopic and histological activities were evaluated. Twenty-three of the 38 patients had a second colonoscopy and were included in a longitudinal analysis. Numerical results were given as the means ± SD of the sample and range, except when specified. Student t analysis, U Mann Whitney and ANOVA factor were used to compare the means. Qualitative results were based on the χ2 test. RESULTS: SLIT2 methylation was more frequent in samples with endoscopic activity than with endoscopic remission (55% vs 18%, P < 0.001). SLIT2 methylation was also higher in samples with acute inflammation (56.5%) than in samples with chronic (24%) or absent inflammation (15%) (P < 0.001). For TGFB2 methylation, the correlation was only significant with endoscopic activity. Methylation was higher in the distal colon for both genes (P < 0.001 for SLIT2 and P = 0.022 for TGFB2). In the multivariate analysis, only inflammation status (and not disease duration or extension) was independently associated with SLIT2 methylation [OR = 6.6 (95%CI: 1.65-27.36), P = 0.009]. In the longitudinal analysis, the maintenance of endoscopic remission was protective for methylation. CONCLUSION: Endoscopic and histological inflammation are predictive for SLIT2 methylation. PMID:25132780
2012-04-01
Both flame lengths shrink and large scale disruptions occur downstream with vortex shedding carrying reaction zones. Flames in both flameholders...9) the flame structure changes dramatically for both regular and open-slit V-gutter. Both flame lengths shrink and large scale disruptions occur...reduces the flame length . However, qualitatively the open-slit V-gutter appears to be more sensitive than the regular V-gutter. Both flames remain
Frizzled-3a and slit2 genetically interact to modulate midline axon crossing in the telencephalon.
Hofmeister, Wolfgang; Devine, Christine A; Rothnagel, Joseph A; Key, Brian
2012-07-01
The anterior commissure forms the first axon connections between the two sides of the embryonic telencephalon. We investigated the role of the transmembrane receptor Frizzled-3a in the development of this commissure using zebrafish as an experimental model. Knock down of Frizzled-3a resulted in complete loss of the anterior commissure. This defect was accompanied by a loss of the glial bridge, expansion of the slit2 expression domain and perturbation of the midline telencephalic-diencephalic boundary. Blocking Slit2 activity following knock down of Frizzled-3a effectively rescued the anterior commissure defect which suggested that Frizzled-3a was indirectly controlling the growth of axons across the rostral midline. We have shown here that Frizzled-3a is essential for normal development of the commissural plate and that loss-of-function causes Slit2-dependent defects in axon midline crossing in the embryonic vertebrate forebrain. These data supports a model whereby Wnt signaling through Frizzled-3a attenuates expression of Slit2 in the rostral midline of the forebrain. The absence of Slit2 facilitates the formation of a midline bridge of glial cells which is used as a substrate for commissural axons. In the absence of this platform of glia, commissural axons fail to cross the rostral midline of the forebrain. Crown Copyright © 2012. Published by Elsevier Ireland Ltd. All rights reserved.
Comparison of fan beam, slit-slat and multi-pinhole collimators for molecular breast tomosynthesis.
van Roosmalen, Jarno; Beekman, Freek J; Goorden, Marlies C
2018-05-16
Recently, we proposed and optimized dedicated multi-pinhole molecular breast tomosynthesis (MBT) that images a lightly compressed breast. As MBT may also be performed with other types of collimators, the aim of this paper is to optimize MBT with fan beam and slit-slat collimators and to compare its performance to that of multi-pinhole MBT to arrive at a truly optimized design. Using analytical expressions, we first optimized fan beam and slit-slat collimator parameters to reach maximum sensitivity at a series of given system resolutions. Additionally, we performed full system simulations of a breast phantom containing several tumours for the optimized designs. We found that at equal system resolution the maximum achievable sensitivity increases from pinhole to slit-slat to fan beam collimation with fan beam and slit-slat MBT having on average a 48% and 20% higher sensitivity than multi-pinhole MBT. Furthermore, by inspecting simulated images and applying a tumour-to-background contrast-to-noise (TB-CNR) analysis, we found that slit-slat collimators underperform with respect to the other collimator types. The fan beam collimators obtained a similar TB-CNR as the pinhole collimators, but the optimum was reached at different system resolutions. For fan beam collimators, a 6-8 mm system resolution was optimal in terms of TB-CNR, while with pinhole collimation highest TB-CNR was reached in the 7-10 mm range.
Adherence issues related to sublingual immunotherapy as perceived by allergists
Scurati, Silvia; Frati, Franco; Passalacqua, Gianni; Puccinelli, Paola; Hilaire, Cecile; Incorvaia, Cristoforo
2010-01-01
Objectives: Sublingual immunotherapy (SLIT) is a viable alternative to subcutaneous immunotherapy to treat allergic rhinitis and asthma, and is widely used in clinical practice in many European countries. The clinical efficacy of SLIT has been established in a number of clinical trials and meta-analyses. However, because SLIT is self-administered by patients without medical supervision, the degree of patient adherence with treatment is still a concern. The objective of this study was to evaluate the perception by allergists of issues related to SLIT adherence. Methods: We performed a questionnaire-based survey of 296 Italian allergists, based on the adherence issues known from previous studies. The perception of importance of each item was assessed by a VAS scale ranging from 0 to 10. Results: Patient perception of clinical efficacy was considered the most important factor (ranked 1 by 54% of allergists), followed by the possibility of reimbursement (ranked 1 by 34%), and by the absence of side effects (ranked 1 by 21%). Patient education, regular follow-up, and ease of use of SLIT were ranked first by less than 20% of allergists. Conclusion: These findings indicate that clinical efficacy, cost, and side effects are perceived as the major issues influencing patient adherence to SLIT, and that further improvement of adherence is likely to be achieved by improving the patient information provided by prescribers. PMID:20622914
Experimental and Analytical Studies of Shielding Concepts for Point Sources and Jet Noise.
1983-05-01
proximnity of the turbulent jet flow to the The Spectral Dynamics DSP 360 is a two channel real time analyzer incor- shielding surface, the edge will interact...However, this is achieved with a very long shield length equal to 190 unorthodox configurations. The emphasis is placed on the concept, times the slit...16 dB/dec. .Vn With this solid-gaseous combination, a 10 0 diameter shield of length 14 DVf =- sin 0 with a burner attached to the trailing edge
New gonioscopy system using only infrared light.
Sugimoto, Kota; Ito, Kunio; Matsunaga, Koichi; Miura, Katsuya; Esaki, Koji; Uji, Yukitaka
2005-08-01
To describe an infrared gonioscopy system designed to observe the anterior chamber angle under natural mydriasis in a completely darkened room. An infrared light filter was used to modify the light source of the slit-lamp microscope. A television monitor connected to a CCD monochrome camera was used to indirectly observe the angle. Use of the infrared system enabled observation of the angle under natural mydriasis in a completely darkened room. Infrared gonioscopy is a useful procedure for the observation of the angle under natural mydriasis.
Robo1/2 regulate follicle atresia through manipulating granulosa cell apoptosis in mice
Li, Jiangchao; Ye, Yuxiang; Zhang, Renli; Zhang, Lili; Hu, Xiwen; Han, Dong; Chen, Jiayuan; He, Xiaodong; Wang, Guang; Yang, Xuesong; Wang, Lijing
2015-01-01
Secreted Slit proteins and their Roundabout (Robo) receptors act as a repulsive cue to preventaxons from migrating to inappropriate locations during the development of the nervous system. Slit/Robo has also been implicated in reproductive system development, but the molecular mechanism of the Slit/Robo pathway in the reproductive system remains poorly understood. Using a transgenic mouse model, we investigated the function of the Slit/Robo pathway on ovarian follicle development and atresia. We first demonstrated that more offspring were born to mice with a partial knockout of the Robo1/2 genes in mice. We next showed that Robo1 and Robo2 are strongly expressed in ovarian granulosacells. Apoptosis in granulosa cells was reduced when Robo1/2 were partially knocked out, and this observation was further verified by in vitro Robo1/2 knockout experiments in mouse and human granulosa cells. We also found that ovarian angiogenesis wasenhanced by a partial lack of Robo1/2 genes. In summary, our data suggest that the Slit/Robo pathway can impact follicle development and atresia by influencinggranulosa cell apoptosis. PMID:25988316
Slit2 as a β-catenin/Ctnnb1-dependent retrograde signal for presynaptic differentiation
Wu, Haitao; Barik, Arnab; Lu, Yisheng; Shen, Chengyong; Bowman, Andrew; Li, Lei; Sathyamurthy, Anupama; Lin, Thiri W; Xiong, Wen-Cheng; Mei, Lin
2015-01-01
Neuromuscular junction formation requires proper interaction between motoneurons and muscle cells. β-Catenin (Ctnnb1) in muscle is critical for motoneuron differentiation; however, little is known about the relevant retrograde signal. In this paper, we dissected which functions of muscle Ctnnb1 are critical by an in vivo transgenic approach. We show that Ctnnb1 mutant without the transactivation domain was unable to rescue presynaptic deficits of Ctnnb1 mutation, indicating the involvement of transcription regulation. On the other hand, the cell-adhesion function of Ctnnb1 is dispensable. We screened for proteins that may serve as a Ctnnb1-directed retrograde factor and identified Slit2. Transgenic expression of Slit2 specifically in the muscle was able to diminish presynaptic deficits by Ctnnb1 mutation in mice. Slit2 immobilized on beads was able to induce synaptophysin puncta in axons of spinal cord explants. Together, these observations suggest that Slit2 serves as a factor utilized by muscle Ctnnb1 to direct presynaptic differentiation. DOI: http://dx.doi.org/10.7554/eLife.07266.001 PMID:26159615
Fabre, Caroline C G; Casal, José; Lawrence, Peter A
2010-09-01
The abdomen of adult Drosophila bears mechanosensory bristles with axons that connect directly to the CNS, each hemisegment contributing a separate nerve bundle. Here, we alter the amount of Engrailed protein and manipulate the Hedgehog signalling pathway in clones of cells to study their effects on nerve pathfinding within the peripheral nervous system. We find that high levels of Engrailed make the epidermal cells inhospitable to bristle neurons; sensory axons that are too near these cells are either deflected or fail to extend properly or at all. We then searched for the engrailed-dependent agent responsible for these repellent properties. We found slit to be expressed in the P compartment and, using genetic mosaics, present evidence that Slit is the responsible molecule. Blocking the activity of the three Robo genes (putative receptors for Slit) with RNAi supported this hypothesis. We conclude that, during normal development, gradients of Slit protein repel axons away from compartment boundaries - in consequence, the bristles from each segment send their nerves to the CNS in separated sets.
Ultra-small and broadband polarization splitters based on double-slit interference
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, Chengwei; Li, Hongyun; Gong, Qihuang
2016-03-07
An ultra-small and broadband polarization splitter is numerically and experimentally demonstrated based on the double-slit interference in a polymer-film-coated double-slit structure. The hybrid slab waveguide (air-polymer-Au) supports both the transverse-magnetic and transverse-electric modes. The incident beam from the back side can excite these two guided modes of orthogonally polarized states in the hybrid structure. By exploiting the difference slit widths and the large mode birefringence, these two guided modes propagate to the opposite directions along the front metal surface. Moreover, the short interference length broadens the operation bandwidth. Experimentally, a polarization splitter with a lateral dimension of only about 1.6 μmmore » and an operation bandwidth of 50 nm is realized. By designing the double-slit structure in a hybrid strip waveguide, the device dimension can be significant downscaled to about 0.3 × 1.3 μm{sup 2}. Such an ultra-small and broadband polarization splitter may find important applications in the integrated photonic circuits.« less
40 CFR 458.45 - Standards of performance for new sources.
Code of Federal Regulations, 2010 CFR
2010-07-01
... paragraph, which may be discharged from the carbon black lamp process by a new source subject to the provisions of this subpart: There shall be no discharge of process waste water pollutants to navigable waters. ...) EFFLUENT GUIDELINES AND STANDARDS CARBON BLACK MANUFACTURING POINT SOURCE CATEGORY Carbon Black Lamp...
Code of Federal Regulations, 2011 CFR
2011-07-01
... available technology economically achievable if discharges from such point sources normally exhibit a pH of... discharges from such point sources normally exhibit a pH equal to or greater than 6.0 prior to treatment: BAT... concentration or quality of pollutants which may be discharged by any existing coal preparation plant and coal...
Code of Federal Regulations, 2010 CFR
2010-07-01
... available technology economically achievable if discharges from such point sources normally exhibit a pH of... discharges from such point sources normally exhibit a pH equal to or greater than 6.0 prior to treatment: BAT... concentration or quality of pollutants which may be discharged by any existing coal preparation plant and coal...
Alger, Terry W.; Schlitt, Leland G.; Bradley, Laird P.
1976-06-15
A laser cavity electron beam injection device provided with a single elongated slit window for passing a suitably shaped electron beam and means for varying the current density of the injected electron beam.
Generation of surface plasmons with compact devices
NASA Astrophysics Data System (ADS)
Baron, A.; Lalanne, P.; Gan, C. H.; Hugonin, J. P.
2013-03-01
We review the properties of the generation of surface plasmons by subwavelength isolated slits in metal films and by small ensembles of slits. After an introduction, in Section 2, we recall the theoretical modal formalism that allows us to calculate the generation efficiency of SPP from the total field scattered by an indentation on a metal film. We also rapidly discuss the main results known of the SPP generation efficiency by subwavelength tiny slits or grooves. In Section 3, we consider the special case of wavelength-large slits that support two propagative modes and that allow us to dynamically control the direction of generated surface plasmons. In Section 4, we conclude by describing a compact and efficient device capable of launching SPPs in a single direction with a normally incident beam.
Measurement-induced decoherence and information in double-slit interference
Kincaid, Joshua; McLelland, Kyle; Zwolak, Michael
2016-01-01
The double slit experiment provides a classic example of both interference and the effect of observation in quantum physics. When particles are sent individually through a pair of slits, a wave-like interference pattern develops, but no such interference is found when one observes which “path” the particles take. We present a model of interference, dephasing, and measurement-induced decoherence in a one-dimensional version of the double-slit experiment. Using this model, we demonstrate how the loss of interference in the system is correlated with the information gain by the measuring apparatus/observer. In doing so, we give a modern account of measurement in this paradigmatic example of quantum physics that is accessible to students taking quantum mechanics at the graduate or senior undergraduate levels. PMID:27807373
Propellant Feed System for Swirl-Coaxial Injection
NASA Technical Reports Server (NTRS)
Reynolds, David Christopher (Inventor)
2015-01-01
A propellant feed system for swirl-coaxial injection of a liquid propellant includes a reservoir having a bottom plate and at least one tube originating in the bottom plate and extending therefrom. The tube has rectangular slits defined in and distributed tangentially and evenly about a portion of the tube that is disposed in the bottom plate. Drain holes are provided in the bottom plate and tunnels are defined in the bottom plate. Each tunnel fluidly couples one of the drain holes to a corresponding one of the rectangular slits. Each tunnel includes (i) a bend of at least 90.degree., and (ii) a straight portion leading to its corresponding rectangular slit wherein the straight portion is at least five times as long as a hydraulic diameter of the corresponding rectangular slit.
VizieR Online Data Catalog: Spectroscopy of candidate members in Taurus (Luhman+, 2017)
NASA Astrophysics Data System (ADS)
Luhman, K. L.; Mamajek, E. E.; Shukla, S. J.; Loutrel, N. P.
2017-06-01
We have obtained optical and near-infrared spectra of candidate members of Taurus. The spectra were collected with the Gemini Near-Infrared Imager (NIRI) using the K-band grism and 0.47'' slit (1.9-2.5μm, R=700), the Gemini Multi-Object Spectrograph (GMOS) using the 400line/mm grating and 0.75'' slit (0.56-1μm, R=1500), the Marcario Low-Resolution Spectrograph (LRS) on the Hobby-Eberly Telescope (HET) using the G3 grism and 2'' slit (0.63-0.91μm, R=1100), and SpeX at the NASA Infrared Telescope Facility (IRTF) using either the prism or SXD mode (R=150/750) and 0.8'' slit (0.8-2.5μm). (7 data files).
Efficient optical cloud removal technique for earth observation based on MOEMs device
NASA Astrophysics Data System (ADS)
Zamkotsian, Frédéric; Lanzoni, Patrick; Liotard, Arnaud; Viard, Thierry; Noell, Wilfried
2017-11-01
In Earth Observation instruments, observation of scenes including bright sources leads to an important degradation of the recorded signal. We propose a new concept to remove dynamically the bright sources and then obtain a field of view with an optically enhanced Signal-to-Noise Ratio (SNR). Micro-Opto-Electro-Mechanical Systems (MOEMS) could be key components in future generation of space instruments. MOEMS-based programmable slit masks will permit the straylight control in future Earth Observation instruments. Experimental demonstration of this concept has been conducted on a dedicated bench. This successful first demonstration shows the high potential of this new concept in future spectro-imager for Earth Observation.
Kasper, Joshua W.; Denver, Judish M.; McKenna, Thomas E.; Ullman, William J.
2010-01-01
A numerical groundwater-flow model was used to characterize the source area and volume of Phillips Branch, a baseflow-dominated stream incising a highly permeable unconfined aquifer on the low relief Delmarva Peninsula, USA. Particle-tracking analyses indicate that the source area (5.51 km2) is ~20% smaller than the topographically defined watershed (6.85 km2), and recharge entering ~37% of the surface watershed does not discharge to Phillips Branch. Groundwater residence time within the source volume ranges from a few days to almost 100 years, with 95% of the volume "flushing" within 50 years. Artificial discharge from groundwater pumping alters the shape of the source area and reduces baseflow due to the interception of stream flow paths, but has limited impacts on the residence time of groundwater discharged as baseflow. In contrast, artificial recharge from land-based wastewater disposal substantially reduces the source area, lowers the range in residence time due to the elimination of older flow paths to the stream, and leads to increased discharge to adjacent surface-water bodies. This research suggests that, in this and similar hydrogeologic settings, the "watershed" approach to water-resource management may be limited, particularly where anthropogenic stresses alter the transport of soluble contaminants through highly permeable unconfined aquifers.
Tong, Yindong; Bu, Xiaoge; Chen, Junyue; Zhou, Feng; Chen, Long; Liu, Maodian; Tan, Xin; Yu, Tao; Zhang, Wei; Mi, Zhaorong; Ma, Lekuan; Wang, Xuejun; Ni, Jing
2017-01-05
Based on a time-series dataset and the mass balance method, the contributions of various sources to the nutrient discharges from the Yangtze River to the East China Sea are identified. The results indicate that the nutrient concentrations vary considerably among different sections of the Yangtze River. Non-point sources are an important source of nutrients to the Yangtze River, contributing about 36% and 63% of the nitrogen and phosphorus discharged into the East China Sea, respectively. Nutrient inputs from non-point sources vary among the sections of the Yangtze River, and the contributions of non-point sources increase from upstream to downstream. Considering the rice growing patterns in the Yangtze River Basin, the synchrony of rice tillering and the wet seasons might be an important cause of the high nutrient discharge from the non-point sources. Based on our calculations, a reduction of 0.99Tg per year in total nitrogen discharges from the Yangtze River would be needed to limit the occurrences of harmful algal blooms in the East China Sea to 15 times per year. The extensive construction of sewage treatment plants in urban areas may have only a limited effect on reducing the occurrences of harmful algal blooms in the future. Copyright © 2016 Elsevier B.V. All rights reserved.
Plasma Ion Sources for Atmospheric Pressure Ionization Mass Spectrometry.
NASA Astrophysics Data System (ADS)
Zhao, Jian-Guo
1994-01-01
Atmospheric pressure ionization (API) sources using direct-current (DC) and radio-frequency (RF) plasma have been developed in this thesis work. These ion sources can provide stable discharge currents of ~ 1 mA, 2-3 orders of magnitude larger than that of the corona discharge, a widely used API source. The plasmas can be generated and maintained in 1 atm of various buffer gases by applying -500 to -1000 V (DC plasma) or 1-15 W with a frequency of 165 kHz (RF plasma) on the needle electrode. These ion sources have been used with liquid injection to detect various organic compounds of pharmaceutical, biotechnological and environmental interest. Key features of these ion sources include soft ionization with the protonated molecule as the largest peak, and superb sensitivity with detection limits in the low picogram or femtomole range and a linear dynamic range over ~4 orders of magnitude. The RF plasma has advantages over the DC plasma in its ability to operate in various buffer gases and to produce a more stable plasma. Factors influencing the performance of the ion sources have been studied, including RF power level, liquid flow rate, chamber temperature, solvent composition, and voltage affecting the collision induced dissociation (CID). Ionization of hydrocarbons by the RF plasma API source was also studied. Soft ionization is generally produced. To obtain high sensitivity, the ion source must be very dry and the needle-to-orifice distance must be small. Nitric oxide was used to enhance the sensitivity. The RF plasma source was then used for the analysis of hydrocarbons in auto emissions. Comparisons between the corona discharge and the RF plasma have been made in terms of discharge current, ion residence time, and the ion source model. The RF plasma source provides larger linear dynamic range and higher sensitivity than the corona discharge, due to its much larger discharge current. The RF plasma was also observed to provide longer ion residence times and was not limited by space-charge effect as in the corona source.
Using a pseudo-thermal light source to teach spatial coherence
NASA Astrophysics Data System (ADS)
Pieper, K.; Bergmann, A.; Dengler, R.; Rockstuhl, C.
2018-07-01
Teaching students spatial coherence constitutes a challenge. On the one hand, discussing it theoretically requires a quite demanding mathematical breadth. On the other hand, discussing it experimentally is hardly possible as coherence usually cannot be directly observed. To solve this problem, we show, by studying the contrast of interference patterns of a double slit, that speckles of a pseudo-thermal light source, consisting of a laser and a rotating diffuser disc, are equivalent to the spatial extent of coherent areas of a thermal light source. Coherent areas are spatial regions within which light can be considered as coherent. The unique advantage of such pseudo-thermal light source is the opportunity to directly observe the spatial extent of the coherent areas. This renders the phenomena perceptible and accessible by various experiments, as described in this contribution. This opens modern paths to teach spatial coherence to students with a notably reduced order of abstraction.
Schuder, Michael D.; Wang, Fang; Chang, Chih-Hsuan; Nesbitt, David J.
2017-01-01
The sub-Doppler CH-symmetric stretch (ν3) infrared absorption spectrum of a hydroxymethyl (CH2OH) radical is observed and analyzed with the radical formed in a slit-jet supersonic discharge expansion (Trot = 18 K) via Cl atom mediated H atom abstraction from methanol. The high sensitivity of the spectrometer and reduced spectral congestion associated with the cooled expansion enable first infrared spectroscopic observation of hydroxymethyl transitions from both ± symmetry tunneling states resulting from large amplitude COH torsional motion. Nuclear spin statistics due to exchange of the two methyl H-atoms aid in unambiguous rovibrational assignment of two A-type Ka = 0 ← 0 and Ka = 1 ← 1 bands out of each ± tunneling state, with additional spectral information obtained from spin-rotation splittings in P, Q, and R branch Ka = 1 ← 1 transitions that become resolved at low N. A high level ab initio potential surface (CCSD(T)-f12b/cc-pvnzf12 (n = 2,3)/CBS) is calculated in the large amplitude COH torsional and CH2 wag coordinates, which in the adiabatic approximation and with zero point correction predicts ground state tunneling splittings in good qualitative agreement with experiment. Of particular astrochemical interest, a combined fit of the present infrared ground state combination differences with recently reported millimeter-wave frequencies permits the determination of improved accuracy rotational constants for the ground vibrational state, which will facilitate ongoing millimeter/microwave searches for a hydroxymethyl radical in the interstellar medium. PMID:28527463
Imaging Spectrometer Designs Utilizing Immersed Gratings With Accessible Entrance Slit
Chrisp, Michael P.; Lerner, Scott A.
2006-03-21
A compact imaging spectrometer comprises an entrance slit, a catadioptric lens with a mirrored surface, a grating, and a detector array. The entrance slit directs light to the mirrored surface of the catadioptric lens; the mirrored surface reflects the light back through the lens to the grating. The grating receives the light from the catadioptric lens and diffracts the light to the lens away from the mirrored surface. The lens transmits the light and focuses it onto the detector array.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marseguerra, M.; Pauli, G.
1958-07-01
The kinetic behavior of thermal neutrons in a time-offlight spectrometer is examined. An analytical method for obtaining the expressions for the probability for slow neutron transmission through a revolving slit (the general case of a curved slit is considered) is presented and discussed in detail. (auth)
DC corona ozone generation enhanced by TiO2 photocatalyst
NASA Astrophysics Data System (ADS)
Pekã¡Rek, S.
2008-12-01
Non-thermal electrical discharges, such as corona discharge are apart of the source of ozone, charged, and excited species and acoustic noise also the source of electromagnetic radiation of different wavelengths. The important component of this radiation from the standpoint of photocatalyst activation is the ultraviolet radiation. We studied the role of UV radiation on corona discharge ozone production by placing the titanium dioxide photocatalyst into the discharge region. We used hollow needle to mesh DC corona discharge at atmospheric pressure with TiO2 globules on the mesh. The discharge was enhanced by the flow of air through the needle. We found that for the needle biased negatively addition of TiO2 photocatalyst on the mesh electrode drastically increases discharge ozone production as well as the ozone production yield. These quantities are also influenced by the mass of the used photocatalyst and its distribution in the discharge chamber.
Design and characterization of a hybrid-integrated MEMS scanning grating spectrometer
NASA Astrophysics Data System (ADS)
Grüger, Heinrich; Knobbe, Jens; Pügner, Tino; Schenk, Harald
2013-03-01
Grating spectrometer, like the well-established Czerny-Turner, are based on an optical design consisting of several components. Typically at least two slits, two mirrors, the grating stage and a detector are required. There has been much work to reduce this effort, setups using only one mirror (Ebert - Fastie) or the replacement of the entrance slit through the use of thin optical fibers as well as integrated electronic detector arrays instead of a moving grating and an exit slit and single detector device have been applied. Reduced effort comes along with performance limitations: Either the optical resolution or throughput is affected or the use of the system is limited to the availability of detectors arrays with reasonable price. Components in micro opto electro mechanical systems (MOEMS-) technology and spectroscopic systems based thereon have been developed to improve this situation. Miniaturized scanning gratings fabricated on bonded silicon on insulator (BSOI-) wafers were used to design grating spectrometer for the near infrared requiring single detectors only. Discrete components offer flexibility but also need for adjustment of two mirrors, grating stage, fiber mount and the detector with its slit and optionally a second slit in the entrance area. Further development leads towards the integration of the slits into the MOEMS chip, thus less effort for adjustment. Flexibility might be reduced as adjustments of the optical design or grating spacing would require a new chip with own set of masks. Nevertheless if extreme miniaturization is desired this approach seems to be promising. Besides this, high volume production might be able for a comparable low price. A new chip was developed offering grating, two slits and a cavity for the detector chip. The optical design was adjusted to a planar arrangement of grating and slits. A detector buried in a chip cavity required a new mounting strategy. Other optical components were optimized and fabricated then the systems was assembled with electronics and software adjusted to the new design including some new features like integrated position sensors. A first test of systems to grant function of all components is presented. Further work will be aimed at improved performance like higher resolution and lower SNR.
Hlushak, Stepan
2018-01-03
Temperature, pressure and pore-size dependences of the heat of adsorption, adsorption stress, and adsorption capacity of methane in simple models of slit and cylindrical carbon pores are studied using classical density functional theory (CDFT) and grand-canonical Monte-Carlo (MC) simulation. Studied properties depend nontrivially on the bulk pressure and the size of the pores. Heat of adsorption increases with loading, but only for sufficiently narrow pores. While the increase is advantageous for gas storage applications, it is less significant for cylindrical pores than for slits. Adsorption stress and the average adsorbed fluid density show oscillatory dependence on the pore size and increase with bulk pressure. Slit pores exhibit larger amplitude of oscillations of the normal adsorption stress with pore size increase than cylindrical pores. However, the increase of the magnitude of the adsorption stress with bulk pressure increase is more significant for cylindrical than for slit pores. Adsorption stress appears to be negative for a wide range of pore sizes and external conditions. The pore size dependence of the average delivered density of the gas is analyzed and the optimal pore sizes for storage applications are estimated. The optimal width of slit pore appears to be almost independent of storage pressure at room temperature and pressures above 10 bar. Similarly to the case of slit pores, the optimal radius of cylindrical pores does not exhibit much dependence on the storage pressure above 15 bar. Both optimal width and optimal radii of slit and cylindrical pores increase as the temperature decreases. A comparison of the results of CDFT theory and MC simulations reveals subtle but important differences in the underlying fluid models employed by the approaches. The differences in the high-pressure behaviour between the hard-sphere 2-Yukawa and Lennard-Jones models of methane, employed by the CDFT and MC approaches, respectively, result in an overestimation of the heat of adsorption by the CDFT theory at higher loadings. However, both adsorption stress and adsorption capacity appear to be much less sensitive to the differences between the models and demonstrate excellent agreement between the theory and the computer experiment.
Characteristics of a lithium-thionyl chloride battery as a memory back-up power source
NASA Astrophysics Data System (ADS)
Iwamaru, T.; Uetani, Y.
An Li/SOCl 2 battery of R6 size (ER6C) has been evaluated as a memory back-up power source for CMOS RAM. The working voltage is 3.6 V and the discharge capacity is 1900 mA h on a 1OK-ohm load. The cell exhibits satisfactory working voltage and discharge capacity over the temperature range -40 °C to 85 °C. The discharge reaction mechanism has been elucidated. Cumulative self discharge during 10 years discharge at 20 μA is estimated to be 3.5%. No serious problems have been observed during abuse tests.
40 CFR 122.29 - New sources and new dischargers.
Code of Federal Regulations, 2013 CFR
2013-07-01
... pollution treatment for the source. (b) Criteria for new source determination. (1) Except as otherwise... located; or (ii) It totally replaces the process or production equipment that causes the discharge of... plant; and the extent to which the new facility is engaged in the same general type of activity as the...
40 CFR 122.29 - New sources and new dischargers.
Code of Federal Regulations, 2012 CFR
2012-07-01
... pollution treatment for the source. (b) Criteria for new source determination. (1) Except as otherwise... located; or (ii) It totally replaces the process or production equipment that causes the discharge of... plant; and the extent to which the new facility is engaged in the same general type of activity as the...
40 CFR 122.29 - New sources and new dischargers.
Code of Federal Regulations, 2011 CFR
2011-07-01
... pollution treatment for the source. (b) Criteria for new source determination. (1) Except as otherwise... located; or (ii) It totally replaces the process or production equipment that causes the discharge of... plant; and the extent to which the new facility is engaged in the same general type of activity as the...
40 CFR 122.29 - New sources and new dischargers.
Code of Federal Regulations, 2014 CFR
2014-07-01
... pollution treatment for the source. (b) Criteria for new source determination. (1) Except as otherwise... located; or (ii) It totally replaces the process or production equipment that causes the discharge of... plant; and the extent to which the new facility is engaged in the same general type of activity as the...
Estimating discharge measurement uncertainty using the interpolated variance estimator
Cohn, T.; Kiang, J.; Mason, R.
2012-01-01
Methods for quantifying the uncertainty in discharge measurements typically identify various sources of uncertainty and then estimate the uncertainty from each of these sources by applying the results of empirical or laboratory studies. If actual measurement conditions are not consistent with those encountered in the empirical or laboratory studies, these methods may give poor estimates of discharge uncertainty. This paper presents an alternative method for estimating discharge measurement uncertainty that uses statistical techniques and at-site observations. This Interpolated Variance Estimator (IVE) estimates uncertainty based on the data collected during the streamflow measurement and therefore reflects the conditions encountered at the site. The IVE has the additional advantage of capturing all sources of random uncertainty in the velocity and depth measurements. It can be applied to velocity-area discharge measurements that use a velocity meter to measure point velocities at multiple vertical sections in a channel cross section.
Spill Prevention and Countermeasures Plan
1984-08-01
THE DISCHARGE OF OiIL AND HAZARDOUS SUBSTANCES AT RMA. THE SPCC PLAN IDENTIFIES POTENTIAL SOURCES OF OIL AND HAZARDOUS SUBSTANCES AND THE MEASURES...Control and Countermeasure (SPCC) Plan is to prevent and control the discharge of oil and hazardous sub- stances at Rocky Mountain Arsenal (RYA). The...SPCC Plan identifies potential sources of oil and hazardous substances and the measures required to prevent an accidental discharge resulting from
NPDES (National Pollution Discharge & Elimination System) Minor Dischargers
As authorized by the Clean Water Act, the National Pollutant Discharge Elimination System (NPDES) permit program controls water pollution by regulating point sources that discharge pollutants into waters of the United States. The NPDES permit program regulates direct discharges from municipal and industrial wastewater treatment facilities that discharge directly into surface waters. The NPDES permit program is part of the Permit Compliance System (PCS) which issues, records, tracks, and regulates point source discharge facilities. Individual homes that are connected to a municipal system, use a septic system, or do not have a surface discharge do not need an NPDES permit. Facilities in PCS are identified as either major or minor. Within the major/minor classification, facilities are grouped into municipals or non-municipals. In many cases, non-municipals are industrial facilities. This data layer contains Minor dischargers. Major municipal dischargers include all facilities with design flows of greater than one million gallons per day; minor dischargers are less that one million gallons per day. Essentially, a minor discharger does not meet the discharge criteria for a major. Since its introduction in 1972, the NPDES permit program is responsible for significant improvements to our Nation's water quality.
Temporal and spatial evolution of nanosecond microwave-driven plasma
NASA Astrophysics Data System (ADS)
Chang, C.; Chen, X. Q.; Zhu, M.; Pu, Y. K.
2018-06-01
In this paper, a method for simultaneously acquiring the temporal and spatial evolution of characteristic plasma spectra in a single microwave pulse is proposed and studied. By using multi-sub-beam fiber bundles coupled with a spectrometer and EMICCD (Electron-multiplying intensified charge-coupled device), the spatial distribution and time evolution of characteristic spectra of desorbed gases at the dielectric/vacuum interface during nanosecond microwave-driven plasma discharge are observed. Arrays of small align tubes punctured with metal walls of feed horn are filled with separate fibers of matched sizes and equal lengths. The output ends of fibers arranged in a single longitudinal column are connected to the entrance slit of a spectrometer, where the optical spectrum inputs to a high-speed EMICCD, to detect the rapid-varying time and space spectra of nanosecond giga-watt microwave discharges. The evolution of spectral clusters of N2 (C-B), N2+ (B-X), and the hydrogen atoms is discovered and monitored. The whole duration of light emission is much longer than the microwave pulse, and the intensities of ion N2+ (B-X) spectra increase after microwave pulses with rise times of 25-50 ns. The brightness distribution of plasma spectra in different space is observed and approximately consistent with the simulated E-field distribution.
Interference-induced angle-independent acoustical transparency
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qi, Lehua; Yu, Gaokun, E-mail: gkyu@ouc.edu.cn; Wang, Ning
2014-12-21
It is revealed that the Fano-like interference leads to the extraordinary acoustic transmission through a slab metamaterial of thickness much smaller than the wavelength, with each unit cell consisting of a Helmholtz resonator and a narrow subwavelength slit. More importantly, both the theoretical analysis and experimental measurement show that the angle-independent acoustical transparency can be realized by grafting a Helmholtz resonator and a quarter-wave resonator to the wall of a narrow subwavelength slit in each unit cell of a slit array. The observed phenomenon results from the interferences between the waves propagating in the slit, those re-radiated by the Helmholtzmore » resonator, and those re-radiated by the quarter-wave resonator. The proposed design may find its applications in designing angle-independent acoustical filters and controlling the phase of the transmitted waves.« less
Tuning Fano resonances with a nano-chamber of air.
Chen, Jianjun; He, Keke; Sun, Chengwei; Wang, Yujia; Li, Hongyun; Gong, Qihuang
2016-05-15
By designing a polymer-film-coated asymmetric metallic slit structure that only contains one nanocavity side-coupled with a subwavelength plasmonic waveguide, the Fano resonance is realized in the experiment. The Fano resonance originates from the interference between the narrow resonant spectra of the radiative light from the nanocavity and the broad nonresonant spectra of the directly transmitted light from the slit. The lateral dimension of the asymmetric slit is only 825 nm. Due to the presence of the soft polymer film, a nano-chamber of air is constructed. Based on the opto-thermal effect, the air volume in the nano-chamber is expanded by a laser beam, which blueshifts the Fano resonance. This tunable Fano resonance in such a submicron slit structure with a nano-chamber is of importance in the highly integrated plasmonic circuits.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Withers, L. P., E-mail: lpwithers@mitre.org; Narducci, F. A., E-mail: francesco.narducci@navy.mil
2015-06-15
The recent single-photon double-slit experiment of Steinberg et al., based on a weak measurement method proposed by Wiseman, showed that, by encoding the photon’s transverse momentum behind the slits into its polarization state, the momentum profile can subsequently be measured on average, from a difference of the separated fringe intensities for the two circular polarization components. They then integrated the measured average velocity field, to obtain the average trajectories of the photons enroute to the detector array. In this paper, we propose a modification of their experiment, to demonstrate that the average particle velocities and trajectories change when the modemore » of detection changes. The proposed experiment replaces a single detector by a pair of detectors with a given spacing between them. The pair of detectors is configured so that it is impossible to distinguish which detector received the particle. The pair of detectors is then analogous to the simple pair of slits, in that it is impossible to distinguish which slit the particle passed through. To establish the paradoxical outcome of the modified experiment, the theory and explicit three-dimensional formulas are developed for the bilocal probability and current densities, and for the average velocity field and trajectories as the particle wavefunction propagates in the volume of space behind the Gaussian slits. Examples of these predicted results are plotted. Implementation details of the proposed experiment are discussed.« less
Slit ventricle syndrome and early-onset secondary craniosynostosis in an infant
Ryoo, Hyun Gee; Kim, Seung-Ki; Cheon, Jung-Eun; Lee, Ji Yeoun; Wang, Kyu-Chang; Phi, Ji Hoon
2014-01-01
Patient: Female, 14 months Final Diagnosis: Slit ventricle syndrome Symptoms: Hydrocephalus • lethargy and seizure • vomiting Medication: — Clinical Procedure: — Specialty: Pediatrics and Neonatology Objective: Challenging differential diagnosis Background: Shunt surgery is a common solution for hydrocephalus in infancy. Slit ventricle syndrome and secondary craniosynostosis are late-onset complications after shunt placement; these 2 conditions occasionally occur together. Case Report: We report a case of early-onset secondary craniosynostosis with slit ventricle syndrome after shunt surgery in an infant, which led to a catastrophic increase in intracranial pressure (ICP). A 4-month-old girl with a Dandy-Walker malformation underwent a ventriculoperitoneal shunt procedure. Her head circumference (HC) gradually decreased to approximately the 5th percentile for her age group after shunt surgery. Seven months later, she developed increased ICP symptoms and underwent a shunt revision with a diagnosis of shunt malfunction. Her symptoms were temporarily relieved, but she repeatedly visited the emergency room (ER) for the same symptoms and finally collapsed, with an abrupt increase in ICP, 3 months later. Further evaluation revealed the emergence of sagittal synostosis at 7 months after initial shunt surgery. After reviewing all clinical data, slit ventricle syndrome combined with secondary craniosynostosis was diagnosed. Emergent cranial expansion surgery with shunt revision was performed, and the increased ICP signs subsided in the following days. Conclusions: Clinical suspicion and long-term HC monitoring are important in the diagnosis of slit ventricle syndrome and secondary craniosynostosis after shunt surgery, even in infants and young children. PMID:24944727
Comparison of fan beam, slit-slat and multi-pinhole collimators for molecular breast tomosynthesis
NASA Astrophysics Data System (ADS)
van Roosmalen, Jarno; Beekman, Freek J.; Goorden, Marlies C.
2018-05-01
Recently, we proposed and optimized dedicated multi-pinhole molecular breast tomosynthesis (MBT) that images a lightly compressed breast. As MBT may also be performed with other types of collimators, the aim of this paper is to optimize MBT with fan beam and slit-slat collimators and to compare its performance to that of multi-pinhole MBT to arrive at a truly optimized design. Using analytical expressions, we first optimized fan beam and slit-slat collimator parameters to reach maximum sensitivity at a series of given system resolutions. Additionally, we performed full system simulations of a breast phantom containing several tumours for the optimized designs. We found that at equal system resolution the maximum achievable sensitivity increases from pinhole to slit-slat to fan beam collimation with fan beam and slit-slat MBT having on average a 48% and 20% higher sensitivity than multi-pinhole MBT. Furthermore, by inspecting simulated images and applying a tumour-to-background contrast-to-noise (TB-CNR) analysis, we found that slit-slat collimators underperform with respect to the other collimator types. The fan beam collimators obtained a similar TB-CNR as the pinhole collimators, but the optimum was reached at different system resolutions. For fan beam collimators, a 6–8 mm system resolution was optimal in terms of TB-CNR, while with pinhole collimation highest TB-CNR was reached in the 7–10 mm range.
Luukko, Keijo; Løes, Sigbjørn; Furmanek, Tomasz; Fjeld, Karianne; Kvinnsland, Inger Hals; Kettunen, Paivi
2003-03-01
The final shape of the molar tooth crown is thought to be regulated by the transient epithelial signaling centers in the cusp tips, the secondary enamel knots (SEKs), which are believed to disappear after initiation of the cusp growth. We investigated the developmental fate of the signaling center using the recently characterized Slit1 enamel knot marker as a lineage tracer during morphogenesis of the first molar and crown calcification in the mouse. In situ hybridization analysis showed that after Fgf4 downregulation in the SEK, Slit1 expression persisted in the deep compartment of the knot. After the histological disappearance of the SEK, Slit1 expression was evident in a novel epithelial cell cluster, which we call the tertiary enamel knot (TEK) next to the enamel-free area (EFA)-epithelium at the cusp tips. In embryonic tooth, Slit1 was also observed in the stratum intermedium (SI) and stellate reticulum cells between the parallel SEKs correlating to the area where the inner enamel epithelium cells do not proliferate. After birth, the expression of Slit1 persisted in the SI cells of the transverse connecting lophs of the parallel cusps above the EFA-cells. These results demonstrate the presence of a novel putative signaling center, the TEK, in the calcifying tooth. Moreover, our results suggest that Slit1 signaling may be involved in the regulation of molar tooth shape by regulating epithelial cell proliferation and formation of EFA of the crown.
Herpetic keratouveitis mixed with bilateral Pseudomonas corneal ulcers in vitamin A deficiency.
Hsu, Hung-Yuan; Tsai, I-Lun; Kuo, Li-Lin; Tsai, Ching-Yao; Liou, Shiow-Wen; Woung, Lin-Chung
2015-02-01
A 56-year-old woman complained of blurred vision and pain in her right eye for several days. Slit lamp examination revealed a large epithelial defect and disciform stromal edema with ring infiltration in her right cornea. Unfortunately, hypopyon and purulent discharge subsequently developed in both eyes. Herpetic keratouveitis and a superimposed pseudomonas infection were diagnosed. A systemic review on the patient showed malnutrition due to her dietary preference and vegetarianism. After the infection was controlled, bilateral epithelial defects persisted for a long time. We performed amniotic membrane transplantation on both eyes and the clinical status improved with administration of vitamin and protein supplements. Although rare in Taiwan, vitamin A deficiency should be kept in mind when conjunctival and corneal xerosis occurred. Vitamin A supplements are suggested because of the increased susceptibility to infection in patients with this clinical status. Copyright © 2012. Published by Elsevier B.V.
Sen, Emine; Elgin, Ufuk; Koç, Fatih; Oztürk, Faruk
2011-01-01
Foreign bodies are usually detected at the first visit. However, they may be overlooked sometimes, especially in children, and may cause some clinical conditions including unilateral relapsing conjunctivitis. A five-year-old girl was presented to the emergency clinic of our hospital with epiphora, purulent discharge, eyelid swelling, and a foreign body feeling in her right eye. The symptoms had been present for one year, and the patient was treated for relapsing conjunctivitis. In slit lamp examination performed with difficulty because of the patient's lack of cooperation, a localized edema and erythema were observed under the right eyelid. An exploration under general anesthesia was planned, and a 1.5 cm-long subconjunctival grass inflorescence was removed. An unknown subconjunctival foreign body should be considered in each patient with relapsing conjunctivitis, especially in children, even in the absence of ocular trauma.
Characteristics of X-Ray Emission from the PFRC-2 Capacitively Coupled Plasma
NASA Astrophysics Data System (ADS)
Oliver, Richard; Pearcy, Jacob; Jandovitz, Peter; Swanson, Charles; Matteucci, Jackson; Cohen, Samuel; PFRC Team
2015-11-01
It is uncertain what causes keV X-rays emitted from the central-cell region of a cool (bulk Te ~ 4 eV), tenuous (ne ~1010 cm-3), 5 cm diameter, weakly ionized hydrogen plasma column generated in a tandem high-mirror-ratio mirror machine (PFRC-2 device) by a low-power, external, capacitively-coupled RF (27 MHz) antenna. We explored whether the energetic electrons responsible for the X-rays exist only in the central cell (ER) or also in the asymmetric mirror regions at opposite ends of the machine, as well as how the spectra compare if they do exist in both regions. To address this, we have designed, built, calibrated, installed and operated an X-ray detector system to view the PFRC-2 region near the RF antenna in one end cell (MC). We observe somewhat different X-ray spectra emanating from the two regions. The system comprises two Amptek XR-100CR detectors with moveable slits that scan across the plasma column. Further control of radial resolution (to 0.4 cm) is afforded by changing the detector-to-slit distance. Calibrations were performed with an 55Fe source. These data are being used to understand the source of the fast electrons that create the X-rays in the MC and in the ER. This work is supported by the US DOE Contract No. DE-AC02-09CH11466 and the Princeton Environmental Institute.
MERLIN - A meV Resolution Beamline at the ALS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reininger, Ruben; Bozek, John; Chuang, Y.-D.
2007-01-19
An ultra-high resolution beamline is being constructed at the Advanced Light Source (ALS) for the study of low energy excitations in strongly correlated systems with the use of high-resolution inelastic scattering and angle-resolved photoemission. This new beamline, given the acronym Merlin (for meV resolution line), will cover the energy range 10-150 eV. The monochromator has fixed entrance and exit slits and a plane mirror that can illuminate a spherical grating at the required angle of incidence (as in the SX-700 mechanism). The monochromator can be operated in two different modes. In the highest resolution mode, the energy scanning requires translatingmore » the monochromator chamber (total travel 1.1 m) as well as rotating the grating and the plane mirror in front of the grating. The resolution in this mode is practically determined by the slits width. In the second mode, the scanning requires rotating the grating and the plane mirror. This mode can be used to scan a few eV without a significant resolution loss. The source for the beamline is a 1.9 m long, 90 mm period quasi periodic EPU. The expected flux at the sample is higher than 1011 photons/s at a resolving power of 5 x 104 in the energy range 16-130 eV. A second set of gratings can be used to obtain higher flux at the expense of resolution.« less
Sodium Velocity Maps on Mercury
NASA Technical Reports Server (NTRS)
Potter, A. E.; Killen, R. M.
2011-01-01
The objective of the current work was to measure two-dimensional maps of sodium velocities on the Mercury surface and examine the maps for evidence of sources or sinks of sodium on the surface. The McMath-Pierce Solar Telescope and the Stellar Spectrograph were used to measure Mercury spectra that were sampled at 7 milliAngstrom intervals. Observations were made each day during the period October 5-9, 2010. The dawn terminator was in view during that time. The velocity shift of the centroid of the Mercury emission line was measured relative to the solar sodium Fraunhofer line corrected for radial velocity of the Earth. The difference between the observed and calculated velocity shift was taken to be the velocity vector of the sodium relative to Earth. For each position of the spectrograph slit, a line of velocities across the planet was measured. Then, the spectrograph slit was stepped over the surface of Mercury at 1 arc second intervals. The position of Mercury was stabilized by an adaptive optics system. The collection of lines were assembled into an images of surface reflection, sodium emission intensities, and Earthward velocities over the surface of Mercury. The velocity map shows patches of higher velocity in the southern hemisphere, suggesting the existence of sodium sources there. The peak earthward velocity occurs in the equatorial region, and extends to the terminator. Since this was a dawn terminator, this might be an indication of dawn evaporation of sodium. Leblanc et al. (2008) have published a velocity map that is similar.
Neutral particle dynamics in a high-power RF source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Todorov, D., E-mail: dimitar-tdrv@phys.uni-sofia.bg; Paunska, Ts.; Shivarova, A.
2015-04-08
Previous studies on the spatial discharge structure in the SPIDER source of negative hydrogen/deuterium ions carried out at low applied power are extended towards description of the discharge maintenance under the conditions of the actual rf power deposition of 100 kW planned for a single driver of the source. In addition to the expected higher electron density, the results show strong increase of the electron temperature and of the temperatures of the neutral species (hydrogen atoms and molecules). In the discussions, not only the spatial distribution of the plasma parameters but also that of the fluxes in the discharge (particlemore » and energy fluxes) is involved. The obtained results come in confirmation of basic concepts for low-pressure discharge maintenance: (i) mutually related electron density and temperature as a display of the generalized Schottky condition, (ii) discharge behavior governed by the fluxes, i.e. strong nonlocality in the discharge, and (iii) a non-ambipolarity in the discharge regime, which originates from shifted maxima of the electron density and temperature and shows evidence in a vortex electron flux and in a dc current in a rf discharge, the latter resulting from a shift in the positions of the maxima of the electron density and plasma potential.« less
Targeting skeletal endothelium to ameliorate bone loss.
Xu, Ren; Yallowitz, Alisha; Qin, An; Wu, Zhuhao; Shin, Dong Yeon; Kim, Jung-Min; Debnath, Shawon; Ji, Gang; Bostrom, Mathias P; Yang, Xu; Zhang, Chao; Dong, Han; Kermani, Pouneh; Lalani, Sarfaraz; Li, Na; Liu, Yifang; Poulos, Michael G; Wach, Amanda; Zhang, Yi; Inoue, Kazuki; Di Lorenzo, Annarita; Zhao, Baohong; Butler, Jason M; Shim, Jae-Hyuck; Glimcher, Laurie H; Greenblatt, Matthew B
2018-06-01
Recent studies have identified a specialized subset of CD31 hi endomucin hi (CD31 hi EMCN hi ) vascular endothelium that positively regulates bone formation. However, it remains unclear how CD31 hi EMCN hi endothelium levels are coupled to anabolic bone formation. Mice with an osteoblast-specific deletion of Shn3, which have markedly elevated bone formation, demonstrated an increase in CD31 hi EMCN hi endothelium. Transcriptomic analysis identified SLIT3 as an osteoblast-derived, SHN3-regulated proangiogenic factor. Genetic deletion of Slit3 reduced skeletal CD31 hi EMCN hi endothelium, resulted in low bone mass because of impaired bone formation and partially reversed the high bone mass phenotype of Shn3 -/- mice. This coupling between osteoblasts and CD31 hi EMCN hi endothelium is essential for bone healing, as shown by defective fracture repair in SLIT3-mutant mice and enhanced fracture repair in SHN3-mutant mice. Finally, administration of recombinant SLIT3 both enhanced bone fracture healing and counteracted bone loss in a mouse model of postmenopausal osteoporosis. Thus, drugs that target the SLIT3 pathway may represent a new approach for vascular-targeted osteoanabolic therapy to treat bone loss.
Rheometry of polymer melts using processing machines
NASA Astrophysics Data System (ADS)
Friesenbichler, Walter; Neunhäuserer, Andreas; Duretek, Ivica
2016-08-01
The technology of slit-die rheometry came into practice in the early 1960s. This technique enables engineers to measure the pressure drop very precisely along the slit die. Furthermore, slit-die rheometry widens up the measurable shear rate range and it is possible to characterize rheological properties of complicated materials such as wall slipping PVCs and high-filled compounds like long fiber reinforced thermoplastics and PIM-Feedstocks. With the use of slit-die systems in polymer processing machines e.g., Rauwendaal extrusion rheometer, by-pass extrusion rheometer, injection molding machine rheometers, new possibilities regarding rheological characterization of thermoplastics and elastomers at processing conditions near to practice opened up. Special slit-die systems allow the examination of the pressure-dependent viscosity and the characterization of cross-linking elastomers because of melt preparation and reachable shear rates comparable to typical processing conditions. As a result of the viscous dissipation in shear and elongational flows, when performing rheological measurements for high-viscous elastomers, temperature-correction of the apparent values has to be made. This technique was refined over the last years at Montanuniversitaet. Nowadays it is possible to characterize all sorts of rheological complicated polymeric materials under process- relevant conditions with viscosity values fully temperature corrected.
Towards evidence-based medicine in specific grass pollen immunotherapy.
Calderon, M; Mösges, R; Hellmich, M; Demoly, P
2010-04-01
When initiating grass pollen immunotherapy for seasonal allergic rhinoconjunctivitis, specialist physicians in many European countries must choose between modalities of differing pharmaceutical and regulatory status. We applied an evidence-based medicine (EBM) approach to commercially available subcutaneous and sublingual Gramineae grass pollen immunotherapies (SCIT and SLIT) by evaluating study design, populations, pollen seasons, treatment doses and durations, efficacy, quality of life, safety and compliance. After searching MEDLINE, Embase and the Cochrane Library up until January 2009, we identified 33 randomized, double-blind, placebo-controlled trials (including seven paediatric trials) with a total of 440 specific immunotherapy (SIT)-treated subjects in seven trials (0 paediatric) for SCIT with natural pollen extracts, 168 in three trials (0 paediatric) for SCIT with allergoids, 906 in 16 trials (five paediatric) for natural extract SLIT drops, 41 in two trials (one paediatric) for allergoid SLIT tablets and 1605 in five trials (two paediatric) for natural extract SLIT tablets. Trial design and quality varied significantly within and between SIT modalities. The multinational, rigorous trials of natural extract SLIT tablets correspond to a high level of evidence in adult and paediatric populations. The limited amount of published data on allergoids prevented us from judging the level of evidence for this modality.
AISI/DOE Technology Roadmap Program: Development of Cost-effective, Energy-efficient Steel Framing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nader R. Elhajj
2003-01-06
Steel members in wall construction form a thermal bridge that interrupts the insulation layer of a wall. This causes higher rate of heat transfer by conduction through the wall framing than through other parts of the wall. One method to reduce the thermal bridging effect is to provide a break, such as insulating sheathing. A thermally efficient slit-web and stud was developed in this program to mitigate the conductivity of steel. The thermal performance of the slit-web stud was evaluated at Oak Ridge National Laboratory using hotbox testing. The thermal test results showed that the prototype slit-web stud performed 17%more » better than the solid-web stud, using R-13 fiber glass batts with exterior OSB sheathing and interior drywall. The structural behavior of this slit-web stud was evaluated in axial, bending, shear, shearwall, and stub-column tests. Test results indicated that the slitweb stud performed similarly or better than the solid-web stud in most structural performance characteristics investigated. Thus, the prototype slit-web stud has been shown to be thermally efficient, economiexecy viable, structurally sound, easily manufactured and usable in a range of residential installations.« less
Li, Xing; Gao, Yaru; Jiang, Shuna; Ma, Li; Liu, Chunxiang; Cheng, Chuanfu
2015-02-09
Using an L-shaped metal nanoslit to generate waves of the pure photonic and plasmonic modes simultaneously, we perform an experimental solution for the scattered imaging of the interference of the two waves. From the fringe data of interference, the amplitudes and the wavevector components of the two waves are obtained. The initial phases of the two waves are obtained from the phase map reconstructed with the interference of the scattered image and the reference wave in the interferometer. The difference in the wavevector components gives rise to an additional phase delay. We introduce the scattering theory under Kirchhoff's approximation to metal slit regime and explain the wavevector difference reasonably. The solution of the quantities is a comprehensive reflection of excitation, scattering and interference of the two waves. By decomposing the polarized incident field with respect to the slit element, the scattered image produced by slit of arbitrary shape can be solved with the nanoscale Huygens-Fresnel principle. This is demonstrated by the experimental intensity pattern and phase map produced by a ring-slit and its consistency with the calculated results.
Probing Pre- and In-service Physics Teachers' Knowledge Using the Double-Slit Thought Experiment
NASA Astrophysics Data System (ADS)
Asikainen, Mervi A.; Hirvonen, Pekka E.
2014-09-01
This study describes the use of the double-slit thought experiment as a diagnostic tool for probing physics teachers' understanding. A total of 9 pre-service teachers and 18 in-service teachers with a variety of different experience in modern physics teaching at the upper secondary level responded in a paper-and-pencil test and three of these teachers were interviewed. The results showed that the physics teachers' thought experiments with classical particles, light, and electrons were often partial. Many teachers also suffered a lack of the basic ideas and principles of physics, which probably hindered thought experimenting. In particular, understanding the ontological nature of classical particles, light and electrons seemed to be essential in performing the double-slit experiment in an appropriate way. However, the in-service physics teachers who had teaching experience in modern physics were more prepared for the double-slit thought experiment than the pre-service teachers. The results suggest that both thought experiments and the double-slit experiment should be given more weight in physics teacher education, even if experience in modern physics teaching at upper secondary school seems to some extent to develop teachers' abilities.
Mass Spectrometry Vapor Analysis for Improving Explosives Detection Canine Proficiency
2017-02-10
ionization (SESI), 8,19-21 dielectric barrier discharge ionization (DBDI), 21,22 selected-ion-flow-tube (SIFT), 23,24 and proton transfer reaction...handled only with wood- en or Teflon® spatulas to prevent static discharge . Using these precautions, we never experienced an accidental detonation...ionization (SESI) and dielectric barrier discharge ionization (DBDI) sources were used for vapor ioni- zation. Source temperature was held at 100 o C
Origin of the Norton-type wave scattered by a subwavelength metallic slit
NASA Astrophysics Data System (ADS)
Le Perchec, Jérôme
2015-10-01
We clarify analytically and numerically the physical origin and the behavior of the Norton field scattered by a narrow slit, at optical frequencies. This apparent surface field, which comes in addition to the surface plasmon-polariton and classic cylindrical light waves, features its own radiation lobe associated with oscillating induced currents that spread over both horizontal metallic parts forming the slit. Theory is given taking into account the finite size of the aperture and is illustrated with materials such as gold and amorphous silicon in different spectral regions.
Spectral Analysis of the Shuttle Glow. SPAS II/IBSS Mission - AIS hardware
1992-04-23
Mirror Lens C Reflection) CiraCylindrical/-Lens • Plane Mirror j _Slit Slit Mro Fig. 7. Cross section through the reflective foreoptics of the UV Fig. 6...selection. The gratings in the The slit width of 0.045 mm restricted the angular spectrograph are deposited on Zerodur blanks, which width of the FOV...of th*i short fee-1 hlaa, t do, lmw b*WdW 3Wa APO=E OPTIC I VOL 31, ft. 16 1 1~ toes I 48 Secondary Mlirror Primary Mirror - lntaeranas Ptten Image
McKenzie, K.R.
1959-07-01
An electrode support which permits accurate alignment and adjustment of the electrode in a plurality of planes and about a plurality of axes in a calutron is described. The support will align the slits in the electrode with the slits of an ionizing chamber so as to provide for the egress of ions. The support comprises an insulator, a leveling plate carried by the insulator and having diametrically opposed attaching screws screwed to the plate and the insulator and diametrically opposed adjusting screws for bearing against the insulator, and an electrode associated with the plate for adjustment therewith.
The extraction of negative carbon ions from a volume cusp ion source
NASA Astrophysics Data System (ADS)
Melanson, Stephane; Dehnel, Morgan; Potkins, Dave; McDonald, Hamish; Hollinger, Craig; Theroux, Joseph; Martin, Jeff; Stewart, Thomas; Jackle, Philip; Philpott, Chris; Jones, Tobin; Kalvas, Taneli; Tarvainen, Olli
2017-08-01
Acetylene and carbon dioxide gases are used in a filament-powered volume-cusp ion source to produce negative carbon ions for the purpose of carbon implantation for gettering applications. The beam was extracted to an energy of 25 keV and the composition was analyzed with a spectrometer system consisting of a 90° dipole magnet and a pair of slits. It is found that acetylene produces mostly C2- ions (up to 92 µA), while carbon dioxide produces mostly O- with only trace amounts of C-. Maximum C2- current was achieved with 400 W of arc power and, the beam current and composition were found to be highly dependent on the pressure in the source. The beam properties as a function of source settings are analyzed, and plasma properties are measured with a Langmuir probe. Finally, we describe testing of a new RF H- ion source, found to produce more than 6 mA of CW H- beam.
Correcting STIS CCD Point-Source Spectra for CTE Loss
NASA Technical Reports Server (NTRS)
Goudfrooij, Paul; Bohlin, Ralph C.; Maiz-Apellaniz, Jesus
2006-01-01
We review the on-orbit spectroscopic observations that are being used to characterize the Charge Transfer Efficiency (CTE) of the STIS CCD in spectroscopic mode. We parameterize the CTE-related loss for spectrophotometry of point sources in terms of dependencies on the brightness of the source, the background level, the signal in the PSF outside the standard extraction box, and the time of observation. Primary constraints on our correction algorithm are provided by measurements of the CTE loss rates for simulated spectra (images of a tungsten lamp taken through slits oriented along the dispersion axis) combined with estimates of CTE losses for actual spectra of spectrophotometric standard stars in the first order CCD modes. For point-source spectra at the standard reference position at the CCD center, CTE losses as large as 30% are corrected to within approx.1% RMS after application of the algorithm presented here, rendering the Poisson noise associated with the source detection itself to be the dominant contributor to the total flux calibration uncertainty.
UV and X-ray Evolution of AR12230 as Observed with IRIS and FOXSI-II
NASA Astrophysics Data System (ADS)
Ryan, Daniel; Christe, Steven; Glesener, Lindsay; Vievering, Julie; Krucker, Sam; Ishikawa, Shin-Nosuke
2017-08-01
We present a multi-spectral and spatio-temporal analysis of AR12230 using both UV and X-ray spectroscopic imaging obtained as part of a coordinated observing campaign on 11 December 2014. The campaign involved IRIS (Interface Region Imaging Spectrometer) -- which provides both UV imaging and slit spectrograph observations of optically thick chromospheric and transition region emission -- and FOXSI-II (Focusing Optics X-ray Solar Imager) -- the second in a series of sounding rocket flights which combines grazing incidence direct focusing optics to produce solar X-ray spectroscopic imaging in the range 4-15keV. The active region exhibits a prolonged compact brightening in the IRIS 1330 A and 1400 A slit-jaw channels near the center of the active region throughout the duration of the observations. In the early phase of the observations FOXSI-II shows an X-ray source approximately 20x20 arcsec centered at the same location. The X-ray spectra show the presence of hot (~8 MK) thermal plasma and is suggestive of the presence of non-thermal electrons.. Later, two additional transient, spatially extended, simultaneous brightenings are observed, one of which was captured by the IRIS slit spectrograph. We combine these observations to explore the evolution and topology of the active region. Hydrodynamic modeling of the chromosphere is used to place a limit on the amount of non-thermal electrons required to produce the observed UV emission. This result is then compared to the limit inferred from the FOXSI-II X-ray spectra. Thus, we explore the role of non-thermal electrons and hydrodynamics in the energization and evolution of plasma in active regions.
Small Deflection Energy Analyzer for Energy and Angular Distributions
NASA Technical Reports Server (NTRS)
Herrero, Federico A.
2009-01-01
The development of the Small Deflection Energy Analyzer (SDEA) charged-particle spectrometer for energy and angle distributions responds to a longstanding need to measure the wind velocity vector in Earth s thermosphere, and to obtain the ion-drift vector in the ionosphere. The air and ions above 120 km are endowed with bulk velocities and temperatures just like air near the ground, but with separate spatial and temporal variations. It is important to understand these not only for study of the physics and chemistry of the Sun-Earth connection, but also for spacecraft orbit predictions, and communications through the ionosphere. The SDEA consists of a pair of parallel conducting plates separated by a small distance, with an entrance slit on one end, and an exit slit on the other. A voltage applied to these plates develops an electric field between the plates, and this field deflects ions passing through it. If an ion has too little energy, it will strike one of the plates. If it has too much, it will strike the back wall. An ion with the amount of energy being searched for will have its trajectory bent just enough to exit the back slit. The SDEA units are compact, rectangular, and operate with low voltages. The units can be built up into small arrays. These arrays could be used either to widen the field of view or to sharpen an existing one. This approach can also be used to obtain angular distributions in two planes simultaneously, thus cutting down the ion source power requirements in half. This geometry has enabled a new mass-spectrometer concept that can provide miniaturized mass spectrometers for use in industrial plants, air-pollution monitoring, and noxious-gas detection.
Foundations of DC plasma sources
NASA Astrophysics Data System (ADS)
Tomas Gudmundsson, Jon; Hecimovic, Ante
2017-12-01
A typical dc discharge is configured with the negative cathode at one end and a positive anode at the other end, separated by a gas filled gap, placed inside a long glass cylinder. A few hundred volts between the cathode and anode is required to maintain the discharge. The type of discharge that is formed between the two electrodes depends upon the pressure of the working gas, the nature of the working gas, the applied voltage and the geometry of the discharge. We discuss the current-voltage characteristics of the discharge as well as the distinct structure that develops in the glow discharge region. The dc glow discharge appears in the discharge current range from μA to mA at 0.5-300 Pa pressure. We discuss the various phenomena observed in the dc glow discharge, including the cathode region, the positive column, and striations. The dc glow discharge is maintained by the emission of secondary electrons from the cathode target due to the bombardment of ions. For decades, the dc glow discharge has been used as a sputter source. Then it is often operated as an obstructed abnormal glow discharge and the required applied voltage is in the range 2-5 kV. Typically, the cathode target (the material to be deposited) is connected to a negative voltage supply (dc or rf) and the substrate holder faces the target. The relatively high operating pressure, in the range from 2 to 4 Pa, high applied voltages, and the necessity to have a conductive target limit the application of dc glow discharge as a sputter source. In order to lower the discharge voltage and expand the operation pressure range, the lifetime of the electrons in target vicinity is increased through applying magnetic field, by adding permanent magnets behind the cathode target. This arrangement is coined the magnetron sputtering discharge. The various configurations of the magnetron sputtering discharge and its applications are described. Furthermore, the use of dc discharges for chemical analysis, the Penning discharge and the hollow cathode discharges and some of its applications are briefly discussed.
Plasma characteristics of direct current enhanced cylindrical inductively coupled plasma source
NASA Astrophysics Data System (ADS)
Yue, HUA; Jian, SONG; Zeyu, HAO; Chunsheng, REN
2018-06-01
Experimental results of a direct current enhanced inductively coupled plasma (DCE-ICP) source which consists of a typical cylindrical ICP source and a plate-to-grid DC electrode are reported. With the use of this new source, the plasma characteristic parameters, namely, electron density, electron temperature and plasma uniformity, are measured by Langmuir floating double probe. It is found that DC discharge enhances the electron density and decreases the electron temperature, dramatically. Moreover, the plasma uniformity is obviously improved with the operation of DC and radio frequency (RF) hybrid discharge. Furthermore, the nonlinear enhancement effect of electron density with DC + RF hybrid discharge is confirmed. The presented observation indicates that the DCE-ICP source provides an effective method to obtain high-density uniform plasma, which is desirable for practical industrial applications.
Laser-guided energetic discharges over large air gaps by electric-field enhanced plasma filaments
NASA Astrophysics Data System (ADS)
Théberge, Francis; Daigle, Jean-François; Kieffer, Jean-Claude; Vidal, François; Châteauneuf, Marc
2017-01-01
Recent works on plasma channels produced during the propagation of ultrashort and intense laser pulses in air demonstrated the guiding of electric discharges along the laser path. However, the short plasma lifetime limits the length of the laser-guided discharge. In this paper, the conductivity and lifetime of long plasma channels produced by ultrashort laser pulses is enhanced efficiently over many orders of magnitude by the electric field of a hybrid AC-DC high-voltage source. The AC electric pulse from a Tesla coil allowed to stimulate and maintain the highly conductive channel during few milliseconds in order to guide a subsequent 500 times more energetic discharge from a 30-kV DC source. This DC discharge was laser-guided over an air gap length of two metres, which is more than two orders of magnitude longer than the expected natural discharge length. Long plasma channel induced by laser pulses and stimulated by an external high-voltage source opens the way for wireless and efficient transportation of energetic current pulses over long air gaps and potentially for guiding lightning.
Laser-guided energetic discharges over large air gaps by electric-field enhanced plasma filaments
Théberge, Francis; Daigle, Jean-François; Kieffer, Jean-Claude; Vidal, François; Châteauneuf , Marc
2017-01-01
Recent works on plasma channels produced during the propagation of ultrashort and intense laser pulses in air demonstrated the guiding of electric discharges along the laser path. However, the short plasma lifetime limits the length of the laser-guided discharge. In this paper, the conductivity and lifetime of long plasma channels produced by ultrashort laser pulses is enhanced efficiently over many orders of magnitude by the electric field of a hybrid AC-DC high-voltage source. The AC electric pulse from a Tesla coil allowed to stimulate and maintain the highly conductive channel during few milliseconds in order to guide a subsequent 500 times more energetic discharge from a 30-kV DC source. This DC discharge was laser-guided over an air gap length of two metres, which is more than two orders of magnitude longer than the expected natural discharge length. Long plasma channel induced by laser pulses and stimulated by an external high-voltage source opens the way for wireless and efficient transportation of energetic current pulses over long air gaps and potentially for guiding lightning. PMID:28053312
Luo, Xi; Hong, Haiyu; Tang, Jun; Wu, Xingmei; Lin, Zhibin; Ma, Renqiang; Fan, Yunping; Xu, Geng; Liu, Dabo; Li, Huabin
2016-03-01
MicroRNAs (miRs) were recently recognized to be important for immune cell differentiation and immune regulation. However, whether miRs were involved in allergen-specific immunotherapy (SIT) remains largely unknown. This study sought to examine changes in miR-146a and T regulatory cells in children with persistent allergic rhinitis (AR) after 3 months of subcutaneous immunotherapy (SCIT) and sublingual immunotherapy (SLIT). Twenty-four HDM-sensitized children with persistent AR were enrolled and treated with SCIT (n=13) or SLIT (n=11) for 3 months. Relative miR-146a and Foxp3 mRNA expression, the TRAF6 protein level, and the ratio of post-treatment to baseline IL-10+CD4+ T cells between the SCIT and SLIT groups were examined in the peripheral blood mononuclear cells (PBMCs) of AR patients using quantitative reverse transcription polymerase chain reaction (qRT-PCR), flow cytometry, and Western blot analysis, respectively. Serum levels of IL-5 and IL-10 were determined using ELISA. After 3 months of SIT, both the TNSS and INSS scores were significantly decreased compared to the baseline value (P<0.01). The relative expression of miR-146a and Foxp3 mRNA was significantly increased after both SCIT and SLIT (P<0.01). The ratio of post-treatment to baseline IL-10⁺CD4⁺ T cells and the serum IL-10 level were significantly increased in both the SCIT and SLIT groups (P<0.01), whereas the TRAF6 protein level and serum IL-5 level were significantly decreased (P<0.01). No significant differences in these biomarkers were observed between the SCIT and SLIT groups. Our findings suggest that miR-146a and its related biomarkers may be comparably modulated after both SCIT and SLIT, highlighting miR-146a as a potential therapeutic target for the improved management of AR.
Maloney, Jennifer; Berman, Gary; Gagnon, Remi; Bernstein, David I; Nelson, Harold S; Kleine-Tebbe, Jörg; Kaur, Amarjot; Li, Qing; Nolte, Hendrik
2016-01-01
Dual treatment with grass and ragweed sublingual immunotherapy (SLIT) tablets has not been studied. To characterize the safety and tolerability of dual grass and ragweed SLIT-tablet administration. This open-label, multicenter trial (NCT02256553) enrolled North American adults (N = 102) allergic to grass and ragweed. The trial had 3 periods, each of 2 weeks duration. In period 1, subjects received once-daily timothy grass SLIT tablet (2800 bioequivalent allergen unit; Merck, Inc, Kenilworth, NJ/ALK, Hørsholm, Denmark). In period 2, subjects received a short ragweed SLIT tablet (12 Ambrosia artemisiifolia 1-U; Merck/ALK) every morning and a grass SLIT tablet every evening. In period 3, subjects received once-daily grass and ragweed SLIT tablets within 5 minutes (simultaneous intake). The primary end point was the proportion of subjects with 1 or more local swelling events in each period. Secondary end points were the proportion of subjects with 1 or more local adverse events (AEs), that discontinued the treatment because of AEs, and subjects with 1 or more local AEs requiring treatment. No severe swellings, systemic allergic reactions, asthma attacks, or reactions requiring epinephrine were reported. Most (99%) AEs were graded mild to moderate. The proportions of subjects with 1 or more local swelling events were 14%, 22%, and 15% for periods 1, 2, and 3, respectively. For periods 1, 2, and 3, the proportions of subjects with 1 or more local AEs were 71%, 69%, and 56%, respectively; the proportions discontinuing the treatment because of treatment-related AEs were 5%, 1%, and 2%, and the proportions with 1 or more local AEs requiring treatment were 4%, 4%, and 1%. In this trial, a 4-week sequential SLIT-tablet dosing schedule followed by simultaneous intake of timothy grass and ragweed tablets was well tolerated. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Study on a negative hydrogen ion source with hot cathode arc discharge.
Lin, S H; Fang, X; Zhang, H J; Qian, C; Ma, B H; Wang, H; Li, X X; Zhang, X Z; Sun, L T; Zhang, Z M; Yuan, P; Zhao, H W
2014-02-01
A negative hydrogen (H(-)) ion source with hot cathode arc discharge was designed and fabricated as a primary injector for a 10 MeV PET cyclotron at IMP. 1 mA dc H(-) beam with ɛ N, RMS = 0.08 π mm mrad was extracted at 25 kV. Halbach hexapole was adopted to confine the plasma. The state of arc discharge, the parameters including filament current, arc current, gas pressure, plasma electrode bias, and the ratio of I(e(-))/I(H(-)) were experimentally studied. The discussion on the result, and opinions to improve the source were given.
Demonstrations Using a Fabry-Perot. I. Multiple-Slit Interference
ERIC Educational Resources Information Center
Roychoudhuri, Chandrasekhar
1975-01-01
Describes a demonstration technique for showing multiple-slit interference patterns with the use of a Fabry-Perot etalon and a laser beam. A simple derivation of the analytical expression for such fringes is presented. (Author/CP)
Holographic Animation Apparatus.
ERIC Educational Resources Information Center
Johnston, Sean F.
1979-01-01
Describes a simple apparatus for producing strip holograms with a number of slit-shaped exposures displaced along the vertical direction. The hologram maintains full horizontal parallax, but the slit aperture reduces the vertical viewing angle of the animated object. (Author/GA)
The micro-mirror technology applied to astronomy: ANIS adaptive-slit near Infrared spectrograph
NASA Astrophysics Data System (ADS)
Burgarella, Denis; Buat, Veronique; Bely, Pierre; Grange, Robert
2018-04-01
This paper, "The micro-mirror technology applied to astronomy: ANIS adaptive-slit near Infrared spectrograph," was presented as part of International Conference on Space Optics—ICSO 1997, held in Toulouse, France.
Long-Slit Spectroscopy of R136 in 30 Doradus
NASA Astrophysics Data System (ADS)
Bostroem, K. A.; Crowther, P.; Lennon, D.; Walborn, N. R.
2013-01-01
R136 is a young, large starburst cluster in 30 Doradus. Its size and age make R136 an ideal cluster in which to study the massive end of the initial mass function (IMF), including stars up to 300 solar masses. In HST GO programs 12465 and 13052, the 52x0.2 arcsec slit of the Space Telescope Imaging Spectrograph (STIS) is stepped across the inner 4 arcsecs of R136. Seventeen consecutive slit locations in both the far ultra-violet (FUV) and optical provide low and medium resolution long-slit spectroscopy of over 100 stars in the region, many of which have never been resolved. The FUV data are combined into a single spectrum to simulate the observation of a more distant unresolved cluster. We present a comparison of individual spectra with the integrated cluster spectrum to determine the relative flux contributions of the brightest cluster members.
Ohno, Yumiko; Torikoshi, Masami; Suzuki, Masao; Umetani, Keiji; Imai, Yasuhiko; Uesugi, Kentaro; Yagi, Naoto
2008-07-01
A multislit collimator was designed and fabricated for basic studies on microbeam radiation therapy (MRT) with an x-ray energy of about 100 keV. It consists of 30 slits that are 25 microm high, 30 mm wide, and 5 mm thick in the beam direction. The slits were made of 25 microm-thick polyimide sheets that were separated by 175 microm-thick tungsten sheets. The authors measured the dose distribution of a single microbeam with a mean energy of 125 keV by a scanning slit method using a phosphor coupled to a charge coupled device camera and found that the ratios of the dose at the center of a microbeam to that at midpositions to adjacent slits were 1050 and 760 for each side of the microbeam. This dose distribution was well reproduced by the Monte Carlo simulation code PHITS.
NASA Astrophysics Data System (ADS)
Bartkowiak, M.; Hofmann, T.; Stüßer, N.
2017-02-01
Energy resolution is an important design goal for time-of-flight instruments and neutron spectroscopy. For high-resolution applications, it is required that the burst times of choppers be short, going down to the μs-range. To produce short pulses while maintaining high neutron flux, we propose beam masks with more than two slits on a counter-rotating 2-disc chopper, behind specially adapted focusing multi-channel guides. A novel non-regular arrangement of the slits ensures that the beam opens only once per chopper cycle, when the masks are congruently aligned. Additionally, beam splitting and intensity focusing by guides before and after the chopper position provide high intensities even for small samples. Phase-space analysis and Monte Carlo simulations on examples of four-slit masks with adapted guide geometries show the potential of the proposed setup.
Application of a three-lens slit spatial filter in high power lasers
NASA Astrophysics Data System (ADS)
Xiong, Han
2018-07-01
Combined with partial parameters in National Ignition Facility, the conceptual design of off-axial four-pass main laser optical system with a three-lens slit spatial filter has been discussed. Since the three-lens slit spatial filter can decline the focal intensity by about 3 orders of magnitudes than that in NIF system, the cutoff frequency in main amplifier cavity can be reduced from 51 × DL to 39 × DL for better beam quality. The main laser system for single beam line can be shortened from 174.7 m to 155.7 m and the spatial filter in high vacuum becomes 60 m instead of the original 83.5 m. Additionally, the pinhole closure could be avoided since the declining of focal intensity in slit spatial filter and the absence of pinhole aperture in the other (pinhole) spatial filter, which provides new ideas for the future high-power lasers.
Imaging spectrometer/camera having convex grating
NASA Technical Reports Server (NTRS)
Reininger, Francis M. (Inventor)
2000-01-01
An imaging spectrometer has fore-optics coupled to a spectral resolving system with an entrance slit extending in a first direction at an imaging location of the fore-optics for receiving the image, a convex diffraction grating for separating the image into a plurality of spectra of predetermined wavelength ranges; a spectrometer array for detecting the spectra; and at least one concave sperical mirror concentric with the diffraction grating for relaying the image from the entrance slit to the diffraction grating and from the diffraction grating to the spectrometer array. In one embodiment, the spectrometer is configured in a lateral mode in which the entrance slit and the spectrometer array are displaced laterally on opposite sides of the diffraction grating in a second direction substantially perpendicular to the first direction. In another embodiment, the spectrometer is combined with a polychromatic imaging camera array disposed adjacent said entrance slit for recording said image.
X-ray filter for x-ray powder diffraction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sinsheimer, John Jay; Conley, Raymond P.; Bouet, Nathalie C. D.
Technologies are described for apparatus, methods and systems effective for filtering. The filters may comprise a first plate. The first plate may include an x-ray absorbing material and walls defining first slits. The first slits may include arc shaped openings through the first plate. The walls of the first plate may be configured to absorb at least some of first x-rays when the first x-rays are incident on the x-ray absorbing material, and to output second x-rays. The filters may comprise a second plate spaced from the first plate. The second plate may include the x-ray absorbing material and wallsmore » defining second slits. The second slits may include arc shaped openings through the second plate. The walls of the second plate may be configured to absorb at least some of second x-rays and to output third x-rays.« less
Slit identification for a uranium slab using a binary classifier based on cosmic-ray muon scattering
NASA Astrophysics Data System (ADS)
Xiao, S.; He, W.; Chen, Y.; Dang, X.; Wu, L.; Shuai, M.
2017-12-01
Traditional muon tomographic method has been fraught with difficulty when it is applied to identify some defective high-Z objects or other complicated structures, since it usually gets into trouble when attempting to produce a precise three-dimensional image for such objects. In this paper, we present a binary classifier based on cosmic-ray muon scattering to identify the slit potentially located in a uranium slab. The superiority of this classifier is established by steering clear of the stubborn imaging procedure necessary for the conventional methods. Simulation results demonstrate its capability to spot a horizontal or vertical slit with a reasonable exposure time. The minimum width of a spotted slit is on the level of millimeters or even sub-millimeters. Therefore, this technique will be prospective in terms of monitoring the long-term status of nuclear storage and facilities in real life.
A mask quality control tool for the OSIRIS multi-object spectrograph
NASA Astrophysics Data System (ADS)
López-Ruiz, J. C.; Vaz Cedillo, Jacinto Javier; Ederoclite, Alessandro; Bongiovanni, Ángel; González Escalera, Víctor
2012-09-01
OSIRIS multi object spectrograph uses a set of user-customised-masks, which are manufactured on-demand. The manufacturing process consists of drilling the specified slits on the mask with the required accuracy. Ensuring that slits are on the right place when observing is of vital importance. We present a tool for checking the quality of the process of manufacturing the masks which is based on analyzing the instrument images obtained with the manufactured masks on place. The tool extracts the slit information from these images, relates specifications with the extracted slit information, and finally communicates to the operator if the manufactured mask fulfills the expectations of the mask designer. The proposed tool has been built using scripting languages and using standard libraries such as opencv, pyraf and scipy. The software architecture, advantages and limits of this tool in the lifecycle of a multiobject acquisition are presented.
Eigenmodes of Multilayer Slit Structures
NASA Astrophysics Data System (ADS)
Kovalenko, A. N.
2017-12-01
We generalize the high-efficiency numerical-analytical method of calculating the eigenmodes of a microstrip line, which was proposed in [1], to multilayer slit structures. The obtained relationships make it possible to allow for the multilayer nature of the medium on the basis of solving the electrodynamic problem for a two-layer structure. The algebraic models of a single line and coupled slit lines in a multilayer dielectric medium are constructed. The matrix elements of the system of linear algebraic equations, which is used to determine the expansion coefficients of the electric field inside the slits in a Chebyshev basis, are converted to rapidly convergent series. The constructed models allow one to use computer simulation to obtain numerical results with high speed and accuracy, regardless of the number of dielectric layers. The presented results of a numerical study of the method convergence confirm high efficiency of the method.
Effect of Ground Layer Patterns with Slits on Conducted Noise Currents from Printed Circuit Board
NASA Astrophysics Data System (ADS)
Maeno, Tsuyoshi; Unou, Takanori; Ichikawa, Kouji; Fujiwara, Osamu
Electromagnetic disturbances for vehicle-mounted radios can be caused by conducted noise currents that flows out from electronic equipment for vehicles to wire-harnesses. In this paper, for reducing the conducted noise currents from electronic equipment for vehicles, we made a simulation and experiment on how ground patterns affect the noise currents from three-layer printed circuit boards (PCBs) with slit-types and plane-type ground patterns. As a result, we could confirm that slits on a ground pattern allow conducted noise currents to flow out from PCBs to wire-harnesses. For the PCBs with plane-type ground and one of three slit-type patterns, on the other hand, both the simulation and examination showed that resonance phenomena occur at unexpected low-frequencies. A circuit analysis revealed that the above phenomena can be caused by the imbalance of a bridge circuit consisting of the trace circuits on the PCB.
An advanced negative hydrogen ion source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goncharov, Alexey A., E-mail: gonchar@iop.kiev.ua; Dobrovolsky, Andrey N.; Goretskii, Victor P.
2016-02-15
The results of investigation of emission productivity of negative particles source with cesiated combined discharge are presented. A cylindrical beam of negative hydrogen ions with density about 2 A/cm{sup 2} in low noise mode on source emission aperture is obtained. The total beam current values are up to 200 mA for negative hydrogen ions and up to 1.5 A for all negative particles with high divergence after source. The source has simple design and can produce stable discharge with low level of oscillation.
Hong, Peilong; Li, Liming; Liu, Jianji; Zhang, Guoquan
2016-03-29
Young's double-slit or two-beam interference is of fundamental importance to understand various interference effects, in which the stationary phase difference between two beams plays the key role in the first-order coherence. Different from the case of first-order coherence, in the high-order optical coherence the statistic behavior of the optical phase will play the key role. In this article, by employing a fundamental interfering configuration with two classical point sources, we showed that the high- order optical coherence between two classical point sources can be actively designed by controlling the statistic behavior of the relative phase difference between two point sources. Synchronous position Nth-order subwavelength interference with an effective wavelength of λ/M was demonstrated, in which λ is the wavelength of point sources and M is an integer not larger than N. Interestingly, we found that the synchronous position Nth-order interference fringe fingerprints the statistic trace of random phase fluctuation of two classical point sources, therefore, it provides an effective way to characterize the statistic properties of phase fluctuation for incoherent light sources.
Dar, Nasser Rashid; Khurshid, Tariq
2005-12-01
To determine and compare the diagnostic value of skin biopsy, saline aspirate smears, skin slit smears and skin biopsy impression smears to demonstrate Leishmania tropica (LT) bodies in cutaneous leishmaniasis and to determine any association within the applied diagnostic tests. An analytical study. Department of Dermatology, PNS Shifa, Karachi from January to December 2003. Seventyeight patients of cutaneous leishmaniasis were subjected to saline aspirate smears, skin slit smears, skin biopsy impression smears and skin biopsy and looked for LT bodies. The percentage positivity of all methods was calculated. McNemar test was applied to determine the association between percentage positivities of methods. Skin biopsy showed LT bodies in 70 (89.74%) patients, saline aspirate smears in 24 (30.76%), skin slit smears in 25 (32.05%) and skin biopsy impression smears in 27 (34.61%) patients. Smears demonstrated LT bodies in 10.25% cases in which biopsy was negative. Skin biopsy impression smears showed concordant results with skin biopsy in 20.51%, skin slit smears in 16.66% and saline aspirate smears in 19.25% of cases. Saline aspirate smears were positive in 48.1% of cases in which biopsy impression smears were negative, slit smears were positive in 50.9 % of cases in which biopsy impression smears were negative and slit smears were positive in 37% of cases in which saline aspirate smears were negative. Skin biopsy for histopathology is the most useful method in the demonstration of Leishmania parasite. Sensitivity of smears can be increased by a combination of various skin smears.
X-Ray Diffraction Wafer Mapping Method for Rhombohedral Super-Hetero-Epitaxy
NASA Technical Reports Server (NTRS)
Park, Yoonjoon; Choi, Sang Hyouk; King, Glen C.; Elliott, James R.; Dimarcantonio, Albert L.
2010-01-01
A new X-ray diffraction (XRD) method is provided to acquire XY mapping of the distribution of single crystals, poly-crystals, and twin defects across an entire wafer of rhombohedral super-hetero-epitaxial semiconductor material. In one embodiment, the method is performed with a point or line X-ray source with an X-ray incidence angle approximating a normal angle close to 90 deg, and in which the beam mask is preferably replaced with a crossed slit. While the wafer moves in the X and Y direction, a narrowly defined X-ray source illuminates the sample and the diffracted X-ray beam is monitored by the detector at a predefined angle. Preferably, the untilted, asymmetric scans are of {440} peaks, for twin defect characterization.
Statistical Limits to Super Resolution
NASA Astrophysics Data System (ADS)
Lucy, L. B.
1992-08-01
The limits imposed by photon statistics on the degree to which Rayleigh's resolution limit for diffraction-limited images can be surpassed by applying image restoration techniques are investigated. An approximate statistical theory is given for the number of detected photons required in the image of an unresolved pair of equal point sources in order that its information content allows in principle resolution by restoration. This theory is confirmed by numerical restoration experiments on synthetic images, and quantitative limits are presented for restoration of diffraction-limited images formed by slit and circular apertures.
SALT spectroscopic classification of Gaia18blo as AGN at z=2.09
NASA Astrophysics Data System (ADS)
Wyrzykowski, L.; Gromadzki, Sz.,; Kozlowski, M.; Buckley, D. A. H.; Ihanec, N.
2018-06-01
Gaia18blo (AT2018chv, 13:11:50.55 -37:30:49.43), was discovered by the Gaia Science Alerts programme on 2018-06-05 as a smooth 0.4 mag increase on a 18.9 mag blueish source at Galactic Plane latitude of about 25 deg (http://gsaweb.ast.cam.ac.uk/alerts/alert/Gaia18blo/) We observed the target with the Southern African Large Telescope (SALT) using the Robert Stobie Spectrograph (RSS) on 2018-06-08 with PG300 grating, slit size 1.5 arcsec.
Effects of Ultraviolet Radiation on the Oxygen Uptake Rate of the Rabbit Cornea
1989-07-01
typical of a noncoherent source Optometrist, Ph.D. exposure. IV Effects on Corneal Oxygen Uptake-Lattimore 117 AvxAtl,-blity Codes 1- -il and/or , "t i...romator entrance slit by the housing optics . A 10 reciprocity (i.e., the biologic effects or endpoints cm quartz-enclosed water chamber was placed be...remove the infrared radiation. The exit optical taneous output at 350.7 and 356.4 nm (3:1 ratio), beam was focused by a quartz lens with a beam size
Atom optics in the time domain
NASA Astrophysics Data System (ADS)
Arndt, M.; Szriftgiser, P.; Dalibard, J.; Steane, A. M.
1996-05-01
Atom-optics experiments are presented using a time-modulated evanescent light wave as an atomic mirror in the trampoline configuration, i.e., perpendicular to the direction of the atomic free fall. This modulated mirror is used to accelerate cesium atoms, to focus their trajectories, and to apply a ``multiple lens'' to separately focus different velocity classes of atoms originating from a point source. We form images of a simple two-slit object to show the resolution of the device. The experiments are modelled by a general treatment analogous to classical ray optics.
40 CFR 63.543 - Standards for process sources.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... (a) No owner or operator of a secondary lead smelter shall discharge or cause to be discharged into the atmosphere from any existing, new, or reconstructed blast, reverberatory, rotary, or electric... discharge or cause to be discharged into the atmosphere from any existing, new, or reconstructed blast...
Experimental Analysis of Pseudospark Sourced Electron Beam
NASA Astrophysics Data System (ADS)
Kumar, Niraj; Pal, U. N.; Verma, D. K.; Prajapati, J.; Kumar, M.; Meena, B. L.; Tyagi, M. S.; Srivastava, V.
2011-12-01
The pseudospark (PS) discharge has been shown to be a promising source of high brightness, high intensity electron beam pulses. The PS discharge sourced electron beam has potential applications in plasma filled microwave sources where normal material cathode cannot be used. Analysis of the electron beam profile has been done experimentally for different applied voltages. The investigation has been carried out at different axial and radial location inside the drift space in argon atmosphere. This paper represents experimentally found axial and radial variation of the beam current inside the drift tube of PS discharge based plasma cathode electron (PCE) gun. With the help of current density estimation the focusing and defocusing point of electron beam in axial direction can be analyzed.
Ardila-Rey, Jorge Alfredo; Rojas-Moreno, Mónica Victoria; Martínez-Tarifa, Juan Manuel; Robles, Guillermo
2014-02-19
Partial discharge (PD) detection is a standardized technique to qualify electrical insulation in machines and power cables. Several techniques that analyze the waveform of the pulses have been proposed to discriminate noise from PD activity. Among them, spectral power ratio representation shows great flexibility in the separation of the sources of PD. Mapping spectral power ratios in two-dimensional plots leads to clusters of points which group pulses with similar characteristics. The position in the map depends on the nature of the partial discharge, the setup and the frequency response of the sensors. If these clusters are clearly separated, the subsequent task of identifying the source of the discharge is straightforward so the distance between clusters can be a figure of merit to suggest the best option for PD recognition. In this paper, two inductive sensors with different frequency responses to pulsed signals, a high frequency current transformer and an inductive loop sensor, are analyzed to test their performance in detecting and separating the sources of partial discharges.
Precision Pulse Capsulotomy: Preclinical Safety and Performance of a New Capsulotomy Technology.
Chang, David F; Mamalis, Nick; Werner, Liliana
2016-02-01
To assess the preclinical safety and performance of a new precision pulse capsulotomy (PPC) method. Human cadaver eye studies and surgical, slit-lamp, and histopathologic evaluation in a consecutive series of 20 live rabbits. Human cadaver eyes and New Zealand white rabbits. Precision pulse capsulotomy uses a highly focused, fast, multipulse, low-energy discharge to produce a perfectly round anterior capsulotomy instantaneously and simultaneously along all 360°. Capsulotomies are performed using a disposable handpiece with a soft collapsible tip and circular nitinol cutting element. Miyake-Apple imaging and scanning electron microscopy (SEM) of PPC were conducted in human cadaver eyes. Surgical, postoperative slit-lamp, and histopathologic assessments of PPC were performed in 20 live rabbits and were compared with manual continuous curvilinear capsulorrhexis (CCC) in the fellow eye. Anterior chamber (AC) thermocouple temperature measurements were evaluated in a subset of rabbit eyes. Capsulotomy edge circularity, SEM morphologic features and zonular movement with PPC in human cadaver eyes. Anterior chamber temperature during PPC and grading of ocular inflammation, corneal endothelial damage, anterior capsular opacification (ACO), and posterior capsular opacification (PCO). Miyake-Apple imaging showed minimal zonular stress, and thermocouple measurements demonstrated negligible AC temperature changes during PPC. Precision pulse capsulotomy produced round, complete capsulotomies in all 20 rabbit eyes, leading to successful in-the-bag intraocular lens (IOL) implantation. Slit-lamp examinations at 3 days and 1, 2, and 4 weeks after surgery showed no significant differences between PPC and CCC in corneal edema, AC inflammatory reaction, capsular fibrosis, ACO, and PCO. Postmortem studies showed no difference in the corneal endothelium between PPC and CCC eyes. All IOLs were well centered in PPC eyes, and histopathologic analysis showed no greater inflammatory infiltrates. Precision pulse capsulotomy is a new method to automate consistent creation of a perfectly circular anterior capsulotomy with a disposable handheld instrument that can be used in the normal phacoemulsification surgical sequence. Compared with CCC in fellow rabbit eyes, PPC was equally safe and showed no greater zonular stress compared with CCC in human cadaver eyes. Human cadaver eye SEM showed a much smoother capsulotomy edge compared to those produced by femtosecond laser. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
An investigation into regular recruit wastage from the British Army, 1988.
Jefferson, T O
1990-10-01
A study was made of recruit medical discharges in the British Army in 1988 with the aim of ascertaining the number of medical discharges amongst recruits. AFBs 6863 (Notification of Discharge of a Regular Recruit) were used as the source of data. Recruit medical wastage rate for 1988 was 897 cases, or 16.7% of all known discharges. Three types of medical discharges were present. Four hundred and ninety-six Type 1 or concealed discharges, (9.2% of discharges for all reasons) were made up of cases who had not been boarded and had mainly been discharged under QR 9.381 (defect of enlistment). Two hundred and seventy-five Type 2 discharges (5.1% of discharges for all reasons) represented boarded cases discharged under QR 9.385 (ceasing to fulfil medical requirements). One hundred and twenty-six Type 3 discharges (2.3% of all discharges) were boarded cases mainly discharged under QR 9.381 (defect of enlistment). As all discharges under paragraphs other than QR 9.385 are given administrative discharge outflow code, only the 275 Type 2 discharges (or 31.7% of medical discharges) appeared on the Army's own source of medical data, the TRIMEDS database. This had the effect of concealing the majority of those discharges caused by conditions predating enlistment therefore decreasing the number of known false negatives not detected at recruiting medicals. The biggest causes of discharge were conditions of the lower limbs and back (54.5% of medical discharges), a conglomerate of minor categories of pathology (14.6%), asthma (9.6%) and deformities (7.4%). Within each type the bulk of the discharges was concealed in Type 1 discharges especially for conditions predating enlistment.(ABSTRACT TRUNCATED AT 250 WORDS)
Delineating Landfill Leachate Discharge To An Arsenic Contaminated Waterway
Discharge of contaminated ground water may serve as a primary and on-going source of contamination to surface water. A field investigation was conducted at a Superfund site in Massachusetts, USA to define the locus of contaminant flux and support source identification for arseni...
Note: Triggering behavior of a vacuum arc plasma source
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lan, C. H., E-mail: lanchaohui@163.com; Long, J. D.; Zheng, L.
2016-08-15
Axial symmetry of discharge is very important for application of vacuum arc plasma. It is discovered that the triggering method is a significant factor that would influence the symmetry of arc discharge at the final stable stage. Using high-speed multiframe photography, the transition processes from cathode-trigger discharge to cathode-anode discharge were observed. It is shown that the performances of the two triggering methods investigated are quite different. Arc discharge triggered by independent electric source can be stabilized at the center of anode grid, but it is difficult to achieve such good symmetry through resistance triggering. It is also found thatmore » the triggering process is highly correlated to the behavior of emitted electrons.« less
Energy & mass-charge distribution peculiarities of ion emitted from penning source
NASA Astrophysics Data System (ADS)
Mamedov, N. V.; Kolodko, D. V.; Sorokin, I. A.; Kanshin, I. A.; Sinelnikov, D. N.
2017-05-01
The optimization of hydrogen Penning sources used, in particular, in plasma chemical processing of materials and DLC deposition, is still very important. Investigations of mass-charge composition of these ion source emitted beams are particular relevant for miniature linear accelerators (neutron flux generators) nowadays. The Penning ion source energy and mass-charge ion distributions are presented. The relation between the discharge current abrupt jumps with increasing plasma density in the discharge center and increasing potential whipping (up to 50% of the anode voltage) is shown. Also the energy spectra in the discharge different modes as the pressure and anode potential functions are presented. It has been revealed that the atomic hydrogen ion concentration is about 5-10%, and it weakly depends on the pressure and the discharge current (in the investigated range from 1 to 10 mTorr and from 50 to 1000 μA) and increases with the anode voltage (up 1 to 3,5 kV).
NASA Astrophysics Data System (ADS)
Semenov, A. P.
1986-02-01
A plasmatic ion source was built in which the hollow cathode above the two discharge chamber cathodes is readily replaced upon depletion after 250 to 300 h. The emission outlet hole is restored to original size by replacement of the cathode insert, while gas is continuously admitted by means of a spring mechanism. The source operates in the Penning discharge mode, with argon as the working gas. The hollow cathode is 36 mm long and has an inside diameter of 4 mm. The other two cathodes serve as pole shoes of a toroidal ferrite magnet which produces a longitudinal magnet field of 0.1 T induction in the discharge chamber. All three cathodes are made of magnetic steel and are insulated from cylindrical copper anode by teflon spacers. Heat is dissipated by oil, which carries it away to a water cooled housing compartment. The source generates an ion emission current of 20 mA with a discharge current of 200 mA at a pull voltage of 20kV.
Brandt, Justin; Catchings, Rufus D.; Christensen, Allen H.; Flint, Alan L.; Gandhok, Gini; Goldman, Mark R.; Halford, Keith J.; Langenheim, V.E.; Martin, Peter; Rymer, Michael J.; Schroeder, Roy A.; Smith, Gregory A.; Sneed, Michelle; Martin, Peter
2011-01-01
Agua Caliente Spring, in downtown Palm Springs, California, has been used for recreation and medicinal therapy for hundreds of years and currently (2008) is the source of hot water for the Spa Resort owned by the Agua Caliente Band of the Cahuilla Indians. The Agua Caliente Spring is located about 1,500 feet east of the eastern front of the San Jacinto Mountains on the southeast-sloping alluvial plain of the Coachella Valley. The objectives of this study were to (1) define the geologic structure associated with the Agua Caliente Spring; (2) define the source(s), and possibly the age(s), of water discharged by the spring; (3) ascertain the seasonal and longer-term variability of the natural discharge, water temperature, and chemical characteristics of the spring water; (4) evaluate whether water-level declines in the regional aquifer will influence the temperature of the spring discharge; and, (5) estimate the quantity of spring water that leaks out of the water-collector tank at the spring orifice.
Radiating dipole model of interference induced in spacecraft circuitry by surface discharges
NASA Technical Reports Server (NTRS)
Metz, R. N.
1984-01-01
Spacecraft in geosynchronous orbit can be charged electrically to high voltages by interaction with the space plasma. Differential charging of spacecraft surfaces leads to arc and blowoff discharging. The discharges are thought to upset interior, computer-level circuitry. In addition to capacitive or electrostatic effects, significant inductive and less significant radiative effects of these discharges exist and can be modeled in a dipole approximation. Flight measurements suggest source frequencies of 5 to 50 MHz. Laboratory tests indicate source current strengths of several amperes. Electrical and magnetic fields at distances of many centimeters from such sources can be as large as tens of volts per meter and meter squared, respectively. Estimates of field attenuation by spacecraft walls and structures suggest that interior fields may be appreciable if electromagnetic shielding is much thinner than about 0.025 mm (1 mil). Pickup of such fields by wires and cables interconnecting circuit components could be a source of interference signals of several volts amplitude.
Suchetana, Bihu; Rajagopalan, Balaji; Silverstein, JoAnn
2017-11-15
A regression tree-based diagnostic approach is developed to evaluate factors affecting US wastewater treatment plant compliance with ammonia discharge permit limits using Discharge Monthly Report (DMR) data from a sample of 106 municipal treatment plants for the period of 2004-2008. Predictor variables used to fit the regression tree are selected using random forests, and consist of the previous month's effluent ammonia, influent flow rates and plant capacity utilization. The tree models are first used to evaluate compliance with existing ammonia discharge standards at each facility and then applied assuming more stringent discharge limits, under consideration in many states. The model predicts that the ability to meet both current and future limits depends primarily on the previous month's treatment performance. With more stringent discharge limits predicted ammonia concentration relative to the discharge limit, increases. In-sample validation shows that the regression trees can provide a median classification accuracy of >70%. The regression tree model is validated using ammonia discharge data from an operating wastewater treatment plant and is able to accurately predict the observed ammonia discharge category approximately 80% of the time, indicating that the regression tree model can be applied to predict compliance for individual treatment plants providing practical guidance for utilities and regulators with an interest in controlling ammonia discharges. The proposed methodology is also used to demonstrate how to delineate reliable sources of demand and supply in a point source-to-point source nutrient credit trading scheme, as well as how planners and decision makers can set reasonable discharge limits in future. Copyright © 2017 Elsevier B.V. All rights reserved.
Discharge planning, nursing home placement, and the Internet.
Collier, Eric J; Harrington, Charlene
2005-01-01
Effective discharge planning and well-coordinated case management related to nursing home (NH) placement are key services in acute-care hospitals. (1) identify the individuals and important factors involved in the discharge planning process; (2) describe the types/sources of information used by discharge planners to recommend specific nursing homes for patients and families; and (3) determine which methods are used to evaluate the quality of US nursing homes (NHs). Descriptive study, with a convenience sample of 41 discharge planners and case managers from California acute-care hospitals. This study found that patients, families, friends, and physicians are all involved in the discharge planning process along with discharge planners and/or case managers. Discharge planners/case managers were generally concerned about NH bed availability, geographic location, and financial considerations. Although the discharge planners and case managers were able to articulate important indicators of quality in NHs, such information was not routinely considered during discharge planning activities. Discharge planners and case managers need to play a more central role in the decision-making process related to the selection of a NH, especially because decisions are time-limited and can benefit from a well-planned discharge planning program that uses a variety of data on quality and costs. The widespread use of Internet-based information sources can be expanded to aid this process.
NASA Astrophysics Data System (ADS)
Borrello, M. C.; Scribner, M.; Chessin, K.
2013-12-01
A growing body of research draws attention to the negative environmental impacts on surface water from large livestock facilities. These impacts are mostly in the form of excessive nutrient loading resulting in significantly decreased oxygen levels. Over-application of animal waste on fields as well as direct discharge into surface water from facilities themselves has been identified as the main contributor to the development of hypoxic zones in Lake Erie, Chesapeake Bay and the Gulf of Mexico. Some regulators claim enforcement of water quality laws is problematic because of the nature and pervasiveness of non-point source impacts. Any direct discharge by a facility is a violation of permits governed by the Clean Water Act, unless the facility has special dispensation for discharge. Previous research by the principal author and others has shown runoff and underdrain transport are the main mechanisms by which nutrients enter surface water. This study utilized previous work to determine if the effects of non-point source discharge can be distinguished from direct (point-source) discharge using simple nutrient analysis and dissolved oxygen (DO) parameters. Nutrient and DO parameters were measured from three sites: 1. A stream adjacent to a field receiving manure, upstream of a large livestock facility with a history of direct discharge, 2. The same stream downstream of the facility and 3. A stream in an area relatively unimpacted by large-scale agriculture (control site). Results show that calculating a simple Pearson correlation coefficient (r) of soluble reactive phosphorus (SRP) and ammonia over time as well as temperature and DO, distinguishes non-point source from point source discharge into surface water. The r value for SRP and ammonia for the upstream site was 0.01 while the r value for the downstream site was 0.92. The control site had an r value of 0.20. Likewise, r values were calculated on temperature and DO for each site. High negative correlations between temperature and DO are indicative of a relatively unimpacted stream. Results from this study are commensurate with nutrient correlations and are: r = -0.97 for the upstream site, r = -0.21 for the downstream site and r = -0.89 for the control site. Results from every site tested were statistically significant (p ≤ 0.05). These results support previous studies and demonstrate that the simple analytical techniques mentioned provide an effective means for regulatory agencies and community groups to monitor and identify point source discharge from large livestock facilities.
The transmission characteristics of indoor particles under different ventilation conditions
NASA Astrophysics Data System (ADS)
Lv, Yang; Wang, Haifeng; Wei, Shanshan
2017-11-01
In modern society, ventilation is an important method for removing indoor particles. This study applies the parameter of attenuation index to analyze the effect of the removal of indoor particles in the two typical ventilation strategies called ceiling exhaust and slit exhaust strategy. Experiment was conducted in a chamber and riboflavin particles were used as the indoor particles source, instantaneous microbial detection (IMD) used to measure the particulate concentration. Conclusions can be found that air exchange rate is an important factor affecting the indoor particle concentration distribution. In the process of indoor free settling(air exchange rate is 0 h-1), the deposition rate were 0.086 h-1, 0.122 h-1, 0.173 h-1 for the particles of 0.5-1.0 μm, 1.0-3.0μm and 3.0-5.0 μm. When the air exchange rate increased to 2.5 h-1, the differences in the attenuation index is significant. There was also a significant linear relationship between air exchange rate and attenuation index. Furthermore, the effect of the slit exhaust strategy on the removal of coarse particles is more remarkable as the increasing air exchange rate.
High resolution collimator system for X-ray detector
Eberhard, Jeffrey W.; Cain, Dallas E.
1987-01-01
High resolution in an X-ray computerized tomography (CT) inspection system is achieved by using a collimator/detector combination to limit the beam width of the X-ray beam incident on a detector element to the desired resolution width. In a detector such as a high pressure Xenon detector array, a narrow tapered collimator is provided above a wide detector element. The collimator slits have any desired width, as small as a few mils at the top, the slit width is easily controlled, and they are fabricated on standard machines. The slit length determines the slice thickness of the CT image.
Flow visualization of a non-contact transport device by Coanda effect
NASA Astrophysics Data System (ADS)
Iki, Norihiko; Abe, Hiroyuki; Okada, Takashi
2014-08-01
AIST proposes new technology of non-contact transport device utilizing Coanda effect. A proposed non-contact transport device has a cylindrical body and circular slit for air. The air flow around non-contact device is turbulent and its flow pattern depends on the injection condition. Therefore we tried visualization of the air flow around non -contact device as the first step of PIV measurement. Several tracer particles were tried such as TiO2 particles, water droplets, potatoes starch, rice starch, corn starch. Hot-wire anemometer is employed to velocity measurement. TiO2 particles deposit inside of a slit and clogging of a slit occurs frequently. Potato starch particles do not clog a slit but they are too heavy to trace slow flow area. Water droplets by ultrasonic atomization also deposit inside of slit but they are useful to visualize flow pattern around a non-contact transport device by being supplied from circumference. Coanda effect of proposed non-contact transport device was confirmed and injected air flow pattern switches by a work. Air flow around non-contact trance port device is turbulent and its velocity range is wide. Therefore flow measurement by tracer part icle has traceability issue. Suitable tracer and exposure condition depends on target area.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Collard, L.B.
2003-08-25
This Special Analysis (SA) addresses two contaminants of concern, H-3 and I-129, in three Effluent Treatment Facility (ETF) Activated Carbon Vessels awaiting disposal as solid waste. The Unreviewed Disposal Question (UDQ) evaluation listed two options for disposal of this waste, disposal as Components-in-Grout (CIG) or disposal in Slit Trenches with sealed openings to restrict release of H-3 form the vessels. Consumption of the CIG inventory limit and consumption of CIG facility volume are shown for the ETF vessels to allow easy comparison with the consumption of Slit Trench inventory limit and consumption of the Slit Trench facility volume . Themore » inventory projections are based on doubling the inventory of the three ETF vessels in the E-Area to account for the unknown inventory of three ETF vessels in the ETF. When the grout ultimately is assumed to degrade hydraulically, the water movement is not impeded as much as the release is accelerated by the presence of the grout. Under these conditions for the CIG trenches relative to the Slit Trenches, the well concentrations are higher, the inventory limit is lower and for a given inventory the inventory limit consumption is higher.« less
Local immunological mechanisms of sublingual immunotherapy.
Allam, Jean-Pierre; Novak, Natalija
2011-12-01
To summarize novel insights into the immunological mechanisms of sublingual immunotherapy (SLIT). Within the recent decades, several alternative noninvasive allergen application strategies have been investigated in allergen-specific immunotherapy (AIT), of which intra-oral allergen application to sublingual mucosa has been proven to be well tolerated and effective. To date, SLIT is widely accepted by most allergists as an alternative option to conventional subcutaneous immunotherapy (SCIT). Although detailed immunological mechanisms remain to be elucidated, much scientific effort has been made to shed some light on local and systemic immunological responses to SLIT in mice as well as humans. Only a few studies focused on the detailed mechanisms following allergen application to the oral mucosa as part of the sophisticated mucosal immunological network. Within this network, the pro-tolerogenic properties of local antigen-presenting cells (APCs) such as dendritic cells - which are able to enforce tolerogenic mechanisms and to induce T-cell immune responses - play a central role. Further on, basic research focused not only on the immune response in nasal and bronchial mucosa but also on the systemic T-cell immune response. Thus, much exiting data have been published providing a better understanding of immunological features of SLIT but far more investigations are necessary to uncover further exciting details on the key mechanisms of SLIT.
NASA Astrophysics Data System (ADS)
Maeno, Tsuyoshi; Ueyama, Hiroya; Iida, Michihira; Fujiwara, Osamu
It is well known that electromagnetic disturbances in vehicle-mounted radios are mainly caused by conducted noise currents flowing through wiring-harnesses from vehicle-mounted printed circuit boards (PCBs) with common ground patterns with slits. To suppress the noise current outflows from the PCBs of this kind, we previously measured noise current outflows from simple two-layer PCBs having two parallel signal traces and different ground patterns with/without slits, which revealed that making slits with open ends on the ground patterns in parallel with the traces can reduce the conducted noise currents. In the present study, with the FDTD simulation, we investigated reduction characteristics of the FM-band cross-talk noise levels between two parallel signal traces for eighteen PCBs, which have different ground patterns with/without slits parallel to the traces and dielectric layers with different thickness. As a result, we found that the cross-talk reduction effect due to slits is obtained by 3.6-5.3dB, while the cross-talks between signal traces are reduced in inverse proportion to the square of the dielectric-layer thickness and in proportion to the square of the trace interval and, which can quantitatively be explained from an inductive coupling theory.
Experimental testing of impact force on rigid and flexible barriers - A comparison
NASA Astrophysics Data System (ADS)
Nagl, Georg; Hübl, Johannes; Chiari, Michael
2016-04-01
The Trattenbach endangers the main western railway track of Austria by floods and debris flows. Three check dams for debris retention were built in the proximal fan area several decades ago. With regard to an improvement of the protective function, these structures have to be renewed. The recent concept of the uppermost barrier is a type of an energy dissipation net structure, stopping debris flows with the ability of self-cleaning by subsequent floods or by machinery employment. The access to the basin is achieved through the slit when the net has been removed. This technical structure consists of a rigid open crown dam with a 4m wide slit. This slit is closed with a flexible net. To verify this protective system, 21 small scale experiments were conducted to test and optimize this new type of Slit Net Dam. To determine the forces on the barrier, in a first setup of experiments the impact forces on a rigid wall with 24 load cells were measured. In the second setup the slit barrier with the net was investigated. On four main cables the anchor forces were measured. In a further setup the basal distance between the channel and lowest net was varied. To study the emptying of the basin and the dosing effect on debris flows.
Ultraviolet radiation induced discharge laser
Gilson, Verle A.; Schriever, Richard L.; Shearer, James W.
1978-01-01
An ultraviolet radiation source associated with a suitable cathode-anode electrode structure, disposed in a gas-filled cavity of a high pressure pulsed laser, such as a transverse electric atmosphere (TEA) laser, to achieve free electron production in the gas by photoelectric interaction between ultraviolet radiation and the cathode prior to the gas-exciting cathode-to-anode electrical discharge, thereby providing volume ionization of the gas. The ultraviolet radiation is produced by a light source or by a spark discharge.
Mass discharge assessment at a brominated DNAPL site: Effects of known DNAPL source mass removal
NASA Astrophysics Data System (ADS)
Johnston, C. D.; Davis, G. B.; Bastow, T. P.; Woodbury, R. J.; Rao, P. S. C.; Annable, M. D.; Rhodes, S.
2014-08-01
Management and closure of contaminated sites is increasingly being proposed on the basis of mass flux of dissolved contaminants in groundwater. Better understanding of the links between source mass removal and contaminant mass fluxes in groundwater would allow greater acceptance of this metric in dealing with contaminated sites. Our objectives here were to show how measurements of the distribution of contaminant mass flux and the overall mass discharge emanating from the source under undisturbed groundwater conditions could be related to the processes and extent of source mass depletion. In addition, these estimates of mass discharge were sought in the application of agreed remediation targets set in terms of pumped groundwater quality from offsite wells. Results are reported from field studies conducted over a 5-year period at a brominated DNAPL (tetrabromoethane, TBA; and tribromoethene, TriBE) site located in suburban Perth, Western Australia. Groundwater fluxes (qw; L3/L2/T) and mass fluxes (Jc; M/L2/T) of dissolved brominated compounds were simultaneously estimated by deploying Passive Flux Meters (PFMs) in wells in a heterogeneous layered aquifer. PFMs were deployed in control plane (CP) wells immediately down-gradient of the source zone, before (2006) and after (2011) 69-85% of the source mass was removed, mainly by groundwater pumping from the source zone. The high-resolution (26-cm depth interval) measures of qw and Jc along the source CP allowed investigation of the DNAPL source-zone architecture and impacts of source mass removal. Comparable estimates of total mass discharge (MD; M/T) across the source zone CP reduced from 104 g day- 1 to 24-31 g day- 1 (70-77% reductions). Importantly, this mass discharge reduction was consistent with the estimated proportion of source mass remaining at the site (15-31%). That is, a linear relationship between mass discharge and source mass is suggested. The spatial detail of groundwater and mass flux distributions also provided further evidence of the source zone architecture and DNAPL mass depletion processes. This was especially apparent in different mass-depletion rates from distinct parts of the CP. High mass fluxes and groundwater fluxes located near the base of the aquifer dominated in terms of the dissolved mass flux in the profile, although not in terms of concentrations. Reductions observed in Jc and MD were used to better target future remedial efforts. Integration of the observations from the PFM deployments and the source mass depletion provided a basis for establishing flux-based management criteria for the site.
Mass discharge assessment at a brominated DNAPL site: Effects of known DNAPL source mass removal.
Johnston, C D; Davis, G B; Bastow, T P; Woodbury, R J; Rao, P S C; Annable, M D; Rhodes, S
2014-08-01
Management and closure of contaminated sites is increasingly being proposed on the basis of mass flux of dissolved contaminants in groundwater. Better understanding of the links between source mass removal and contaminant mass fluxes in groundwater would allow greater acceptance of this metric in dealing with contaminated sites. Our objectives here were to show how measurements of the distribution of contaminant mass flux and the overall mass discharge emanating from the source under undisturbed groundwater conditions could be related to the processes and extent of source mass depletion. In addition, these estimates of mass discharge were sought in the application of agreed remediation targets set in terms of pumped groundwater quality from offsite wells. Results are reported from field studies conducted over a 5-year period at a brominated DNAPL (tetrabromoethane, TBA; and tribromoethene, TriBE) site located in suburban Perth, Western Australia. Groundwater fluxes (qw; L(3)/L(2)/T) and mass fluxes (Jc; M/L(2)/T) of dissolved brominated compounds were simultaneously estimated by deploying Passive Flux Meters (PFMs) in wells in a heterogeneous layered aquifer. PFMs were deployed in control plane (CP) wells immediately down-gradient of the source zone, before (2006) and after (2011) 69-85% of the source mass was removed, mainly by groundwater pumping from the source zone. The high-resolution (26-cm depth interval) measures of qw and Jc along the source CP allowed investigation of the DNAPL source-zone architecture and impacts of source mass removal. Comparable estimates of total mass discharge (MD; M/T) across the source zone CP reduced from 104gday(-1) to 24-31gday(-1) (70-77% reductions). Importantly, this mass discharge reduction was consistent with the estimated proportion of source mass remaining at the site (15-31%). That is, a linear relationship between mass discharge and source mass is suggested. The spatial detail of groundwater and mass flux distributions also provided further evidence of the source zone architecture and DNAPL mass depletion processes. This was especially apparent in different mass-depletion rates from distinct parts of the CP. High mass fluxes and groundwater fluxes located near the base of the aquifer dominated in terms of the dissolved mass flux in the profile, although not in terms of concentrations. Reductions observed in Jc and MD were used to better target future remedial efforts. Integration of the observations from the PFM deployments and the source mass depletion provided a basis for establishing flux-based management criteria for the site. Copyright © 2013 Elsevier B.V. All rights reserved.
Blue, C.W.; Luce, J.S.
1960-07-19
An ion source is described and comprises an arc discharge parallel to the direction of and inside of a magnetic field. an accelerating electrode surrounding substantially all of the discharge except for ion exit apertures, and means for establishing an electric field between that electrode and the arc discharge. the electric field being oriented at an acute angle to the magnetic field. Ions are drawn through the exit apertures in the accelrating electrcde in a direction substantially divergent to the direction of the magnetic field and so will travel in a spiral orbit along the magnetic field such that the ions will not strike the source at any point in their orbit within the magnetic field.
Metod And Apparatus For Debris Mitigation For An Electrical Discharge Source
Klebanoff, Leonard E.; Silfvast, William T.; Rader, Daniel J.
2005-05-03
Method and apparatus for mitigating the transport of debris generated and dispersed from electric discharge sources by thermophoretic and electrostatic deposition. A member is positioned adjacent the front electrode of an electric discharge source and used to establish a temperature difference between it and the front electrode. By flowing a gas between the member and the front electrode a temperature gradient is established that can be used for thermophoretic deposition of particulate debris on either the member or front electrode depending upon the direction of the thermal gradient. Establishing an electric field between the member and front electrode can aid in particle deposition by electrostatic deposition.
Method and apparatus for debris mitigation for an electrical discharge source
Klebanoff, Leonard E [San Clemente, CA; Rader, Daniel J [Albuquerque, NM; Silfvast, William T [Helena, CA
2006-01-24
Method and apparatus for mitigating the transport of debris generated and dispersed from electric discharge sources by thermophoretic and electrostatic deposition. A member is positioned adjacent the front electrode of an electric discharge source and used to establish a temperature difference between it and the front electrode. By flowing a gas between the member and the front electrode a temperature gradient is established that can be used for thermophoretic deposition of particulate debris on either the member or front electrode depending upon the direction of the thermal gradient. Establishing an electric field between the member and front electrode can aid in particle deposition by electrostatic deposition.
40 CFR 414.111 - Toxic pollutant standards for indirect discharge point sources.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 29 2014-07-01 2012-07-01 true Toxic pollutant standards for indirect discharge point sources. 414.111 Section 414.111 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS Indirect...
40 CFR 414.111 - Toxic pollutant standards for indirect discharge point sources.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 28 2010-07-01 2010-07-01 true Toxic pollutant standards for indirect discharge point sources. 414.111 Section 414.111 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS Indirect...
40 CFR 414.111 - Toxic pollutant standards for indirect discharge point sources.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 30 2012-07-01 2012-07-01 false Toxic pollutant standards for indirect discharge point sources. 414.111 Section 414.111 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS Indirect...
40 CFR 414.111 - Toxic pollutant standards for indirect discharge point sources.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 29 2011-07-01 2009-07-01 true Toxic pollutant standards for indirect discharge point sources. 414.111 Section 414.111 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS Indirect...
40 CFR 414.111 - Toxic pollutant standards for indirect discharge point sources.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 30 2013-07-01 2012-07-01 true Toxic pollutant standards for indirect discharge point sources. 414.111 Section 414.111 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS ORGANIC CHEMICALS, PLASTICS, AND SYNTHETIC FIBERS Indirect...
Condenser for extreme-UV lithography with discharge source
Sweatt, William C.; Kubiak, Glenn D.
2001-01-01
Condenser system, for use with a ringfield camera in projection lithography, employs quasi grazing-incidence collector mirrors that are coated with a suitable reflective metal such as ruthenium to collect radiation from a discharge source to minimize the effect of contaminant accumulation on the collecting mirrors.
40 CFR 464.44 - New source performance standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., total phenols, oil and grease, and TSS. For non-continuous dischargers, annual average mass standards.... Concentration standards and annual average mass standards shall only apply to non-continuous dischargers. (a... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards. 464...
40 CFR 464.14 - New source performance standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., total phenols, oil and grease, and TSS. For non-continuous dischargers, annual average mass standards.... Concentration standards and annual average mass standards shall only apply to non-continuous dischargers. (a... 40 Protection of Environment 31 2013-07-01 2013-07-01 false New source performance standards. 464...
40 CFR 464.14 - New source performance standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., total phenols, oil and grease, and TSS. For non-continuous dischargers, annual average mass standards.... Concentration standards and annual average mass standards shall only apply to non-continuous dischargers. (a... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards. 464...
40 CFR 464.44 - New source performance standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., total phenols, oil and grease, and TSS. For non-continuous dischargers, annual average mass standards.... Concentration standards and annual average mass standards shall only apply to non-continuous dischargers. (a... 40 Protection of Environment 30 2014-07-01 2014-07-01 false New source performance standards. 464...
40 CFR 464.24 - New source performance standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., total phenols, oil and grease, and TSS. For non-continuous dischargers, annual average mass standards.... Concentration standards and annual average mass standards shall only apply to non-continuous dischargers. (a... 40 Protection of Environment 31 2013-07-01 2013-07-01 false New source performance standards. 464...
40 CFR 464.24 - New source performance standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., total phenols, oil and grease, and TSS. For non-continuous dischargers, annual average mass standards.... Concentration standards and annual average mass standards shall only apply to non-continuous dischargers. (a... 40 Protection of Environment 30 2011-07-01 2011-07-01 false New source performance standards. 464...
40 CFR 464.24 - New source performance standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., total phenols, oil and grease, and TSS. For non-continuous dischargers, annual average mass standards.... Concentration standards and annual average mass standards shall only apply to non-continuous dischargers. (a... 40 Protection of Environment 29 2010-07-01 2010-07-01 false New source performance standards. 464...
40 CFR 464.44 - New source performance standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., total phenols, oil and grease, and TSS. For non-continuous dischargers, annual average mass standards.... Concentration standards and annual average mass standards shall only apply to non-continuous dischargers. (a... 40 Protection of Environment 31 2013-07-01 2013-07-01 false New source performance standards. 464...
40 CFR 464.44 - New source performance standards.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., total phenols, oil and grease, and TSS. For non-continuous dischargers, annual average mass standards.... Concentration standards and annual average mass standards shall only apply to non-continuous dischargers. (a... 40 Protection of Environment 31 2012-07-01 2012-07-01 false New source performance standards. 464...
40 CFR 464.24 - New source performance standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., total phenols, oil and grease, and TSS. For non-continuous dischargers, annual average mass standards.... Concentration standards and annual average mass standards shall only apply to non-continuous dischargers. (a... 40 Protection of Environment 30 2014-07-01 2014-07-01 false New source performance standards. 464...
40 CFR 464.44 - New source performance standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., total phenols, oil and grease, and TSS. For non-continuous dischargers, annual average mass standards.... Concentration standards and annual average mass standards shall only apply to non-continuous dischargers. (a... 40 Protection of Environment 30 2011-07-01 2011-07-01 false New source performance standards. 464...
40 CFR 464.24 - New source performance standards.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., total phenols, oil and grease, and TSS. For non-continuous dischargers, annual average mass standards.... Concentration standards and annual average mass standards shall only apply to non-continuous dischargers. (a... 40 Protection of Environment 31 2012-07-01 2012-07-01 false New source performance standards. 464...
40 CFR 464.14 - New source performance standards.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., total phenols, oil and grease, and TSS. For non-continuous dischargers, annual average mass standards.... Concentration standards and annual average mass standards shall only apply to non-continuous dischargers. (a... 40 Protection of Environment 30 2014-07-01 2014-07-01 false New source performance standards. 464...
40 CFR 464.14 - New source performance standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., total phenols, oil and grease, and TSS. For non-continuous dischargers, annual average mass standards.... Concentration standards and annual average mass standards shall only apply to non-continuous dischargers. (a... 40 Protection of Environment 30 2011-07-01 2011-07-01 false New source performance standards. 464...
40 CFR 464.14 - New source performance standards.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., total phenols, oil and grease, and TSS. For non-continuous dischargers, annual average mass standards.... Concentration standards and annual average mass standards shall only apply to non-continuous dischargers. (a... 40 Protection of Environment 31 2012-07-01 2012-07-01 false New source performance standards. 464...
van der Weele, G M; Rietveld, R P; Wiersma, Tj; Goudswaard, A N
2007-06-02
The revised NHG-guideline 'The red eye' provides recommendations for the diagnosis and therapy in patients with a red eye. In the presence of pain, decreased visual acuity and photophobia (alarm symptoms) should be considered as sight threatening conditions. In most instances a red eye results from conjunctivitis. The complaint of (an) early morning glued eye(s) makes a bacterial origin of acute infectious conjunctivitis more likely. Itching and a history of infectious conjunctivitis make the probability of bacterial involvement less likely. The type of discharge does not help to adequately distinguish bacterial from viral conjunctivitis. Since an infectious conjunctivitis is a self-limiting condition, no treatment is necessary as a rule. Antibiotic treatment is only rational if conjunctivitis is (most probably) caused by bacteria. It has to be considered only if a patient suffers from much discomfort, if complaints do not begin to decline after 3 days and in patients with preexisting corneal defects. Because of widespread resistance to fusidic acid this should in principle not be prescribed for treatment of conjunctivitis; chloramphenicol is still the drug of choice. During revision of the guideline discussions concentrated on 2 aspects: the position of slit lamp biomicroscopy in general practice and giving a patient with keratoconjunctivitis photoelectrica the remainder of a 'minim' with anaesthetic eye drops. Regarding both topics it was decided not to change the recommendations of the former version of the guideline: the use of slit lamp biomicroscopy remains optional for general practitioners and it remains permitted to give the remainder of a 'minim' with anaesthetic eye drops to a patient with keratoconjunctivitis photoelectrica.
NASA Astrophysics Data System (ADS)
Poddar, Raju; Zawadzki, Robert J.; Cortés, Dennis E.; Mannis, Mark J.; Werner, John S.
2015-06-01
We present in vivo volumetric depth-resolved vasculature images of the anterior segment of the human eye acquired with phase-variance based motion contrast using a high-speed (100 kHz, 105 A-scans/s) swept source optical coherence tomography system (SSOCT). High phase stability SSOCT imaging was achieved by using a computationally efficient phase stabilization approach. The human corneo-scleral junction and sclera were imaged with swept source phase-variance optical coherence angiography and compared with slit lamp images from the same eyes of normal subjects. Different features of the rich vascular system in the conjunctiva and episclera were visualized and described. This system can be used as a potential tool for ophthalmological research to determine changes in the outflow system, which may be helpful for identification of abnormalities that lead to glaucoma.
NASA Astrophysics Data System (ADS)
Li, K. Betty; Goovaerts, Pierre; Abriola, Linda M.
2007-06-01
Contaminant mass discharge across a control plane downstream of a dense nonaqueous phase liquid (DNAPL) source zone has great potential to serve as a metric for the assessment of the effectiveness of source zone treatment technologies and for the development of risk-based source-plume remediation strategies. However, too often the uncertainty of mass discharge estimated in the field is not accounted for in the analysis. In this paper, a geostatistical approach is proposed to estimate mass discharge and to quantify its associated uncertainty using multilevel transect measurements of contaminant concentration (C) and hydraulic conductivity (K). The approach adapts the p-field simulation algorithm to propagate and upscale the uncertainty of mass discharge from the local uncertainty models of C and K. Application of this methodology to numerically simulated transects shows that, with a regular sampling pattern, geostatistics can provide an accurate model of uncertainty for the transects that are associated with low levels of source mass removal (i.e., transects that have a large percentage of contaminated area). For high levels of mass removal (i.e., transects with a few hot spots and large areas of near-zero concentration), a total sampling area equivalent to 6˜7% of the transect is required to achieve accurate uncertainty modeling. A comparison of the results for different measurement supports indicates that samples taken with longer screen lengths may lead to less accurate models of mass discharge uncertainty. The quantification of mass discharge uncertainty, in the form of a probability distribution, will facilitate risk assessment associated with various remediation strategies.
Monitoring and Morphologic Classification of Pediatric Cataract Using Slit-Lamp-Adapted Photography.
Long, Erping; Lin, Zhuoling; Chen, Jingjing; Liu, Zhenzhen; Cao, Qianzhong; Lin, Haotian; Chen, Weirong; Liu, Yizhi
2017-11-01
To investigate the feasibility of pediatric cataract monitoring and morphologic classification using slit lamp-adapted anterior segmental photography in a large cohort that included uncooperative children. Patients registered in the Childhood Cataract Program of the Chinese Ministry of Health were prospectively selected. Eligible patients underwent slit-lamp adapted anterior segmental photography to record and monitor the morphology of their cataractous lenses. A set of assistance techniques for slit lamp-adapted photography was developed to instruct the parents of uncooperative children how to help maintain the child's head position and keep the eyes open after sleep aid administration. Briefly, slit lamp-adapted photography was completed for all 438 children, including 260 (59.4%) uncooperative children with our assistance techniques. All 746 images of 438 patients successfully confirmed the diagnoses and classifications. Considering the lesion location, pediatric cataract morphologies could be objectively classified into the seven following types: total; nuclear; polar, including two subtypes (anterior and posterior); lamellar; nuclear combined with cortical, including three subtypes (coral-like, dust-like, and blue-dot); cortical; and Y suture. The top three types of unilateral cataracts were polar (55, 42.3%), total (42, 32.3%), and nuclear (23, 17.7%); and the top three types of bilateral cataracts were nuclear (110, 35.8%), total (102, 33.2%), and lamellar (34, 11.1%). Slit lamp-adapted anterior segmental photography is applicable for monitoring and classifying the morphologies of pediatric cataracts and is even safe and feasible for uncooperative children with assistance techniques and sleep aid administration. This study proposes a novel strategy for the preoperative evaluation and evidence-based management of pediatric ophthalmology (Clinical Trials.gov, NCT02748031).
Chemical laser exhaust pipe design research
NASA Astrophysics Data System (ADS)
Sun, Yunqiang; Huang, Zhilong; Chen, Zhiqiang; Ren, Zebin; Guo, Longde
2016-10-01
In order to weaken the chemical laser exhaust gas influence of the optical transmission, a vent pipe is advised to emissions gas to the outside of the optical transmission area. Based on a variety of exhaust pipe design, a flow field characteristic of the pipe is carried out by numerical simulation and analysis in detail. The research results show that for uniform deflating exhaust pipe, although the pipeline structure is cyclical and convenient for engineering implementation, but there is a phenomenon of air reflows at the pipeline entrance slit which can be deduced from the numerical simulation results. So, this type of pipeline structure does not guarantee seal. For the design scheme of putting the pipeline contract part at the end of the exhaust pipe, or using the method of local area or tail contraction, numerical simulation results show that backflow phenomenon still exists at the pipeline entrance slit. Preliminary analysis indicates that the contraction of pipe would result in higher static pressure near the wall for the low speed flow field, so as to produce counter pressure gradient at the entrance slit. In order to eliminate backflow phenomenon at the pipe entrance slit, concerned with the pipeline type of radial size increase gradually along the flow, flow field property in the pipe is analyzed in detail by numerical simulation methods. Numerical simulation results indicate that there is not reflow phenomenon at entrance slit of the dilated duct. However the cold air inhaled in the slit which makes the temperature of the channel wall is lower than the center temperature. Therefore, this kind of pipeline structure can not only prevent the leak of the gas, but also reduce the wall temperature. In addition, compared with the straight pipe connection way, dilated pipe structure also has periodic structure, which can facilitate system integration installation.
NASA Astrophysics Data System (ADS)
Fujiwara, K.; Shibahara, M.
2018-02-01
Molecular evaporation processes from a vapor-liquid interface formed in a slit-like pore were examined based on the classical molecular dynamics method, in order to elucidate a molecular mechanism of local mass and energy transports in a slit. The calculation system consisted of monatomic molecules and atoms which interact through the 12-6 Lennard-Jones potential. At first, a liquid was situated in a slit with a vapor-liquid interface, and instantaneous amounts of the mass and energy fluxes defined locally in the slit were obtained in two dimensions to reveal local fluctuation properties of the fluid in equilibrium states. Then, imposing a temperature gradient in the calculation system, non-equilibrium evaporation processes in the slit were investigated in details based on the local mass and energy fluxes. In this study, we focused on the fluid which is in the vicinity of the solid surface and in contact with the vapor phase. In the non-equilibrium evaporation processes, the results revealed that the local energy transport mechanism in the vicinity of the solid surface is different from that of the vapor phase, especially in the case of the relatively strong fluid-solid interaction. The results also revealed that the local mass transport in the vicinity of the solid surface can be interpreted based on the mechanism of the local energy transport, and the mechanism provides valuable information about pictures of the evaporation phenomena especially in the vicinity of the hydrophilic surfaces. It suggests that evaluating and changing this mechanism of the local energy transport are necessary to control the local mass flux more precisely in the vicinity of the solid surface.
De Castro, G; Zicari, A M; Indinnimeo, L; Tancredi, G; di Coste, A; Occasi, F; Castagna, G; Giancane, G; Duse, M
2013-08-01
Sublingual-specific immunotherapy (SLIT) is considered as a valid treatment of respiratory allergies. We performed a case-control study to evaluate the effect of SLIT in children with allergic asthma and rhinitis. The study plan included 140 patients (age 6-14 yr, 43% girls and 57% boys) presenting allergic rhinitis and/or asthma, 70 treated with SLIT actively for three years and 70 controls never treated with specific immunotherapy (only symptomatic drugs). Rhinitis Symptom Score (RSS), Asthma Symptom Score (ASS) and Medication Score (MS) were evaluated at beginning and during the 3 years of immunotherapy. results: There was a significant improvement of RSS (mean ± SD) in the SLIT group: baseline 5.31 ± 2.01, third year 1.38 ± 1.06 (p < 0.0001 vs baseline). baseline 5.00 ± 1.08, third year 4.68 ± 1.152 (P ¼ NS). ASS (mean ± SD) in the SLIT group: baseline 4.09 ± 2.21, third year 1.23 ± 1.4 (p < 0.0001 vs baseline). baseline 4.04 ± 2.46, third year 3.62 ± 2.26 (p ¼ NS). MS (mean ± SD) in the SLIT group: baseline 3.30 ± 1.4, third year 0.88 ± 1.26 (p < 0.0001 vs baseline). baseline 3.19 ± 1.23, third year 3.39 ± 1.12 (p ¼ NS). There are no statistically significant differences among monosensitized/polysensitized patients and at different age ranges. None of the patients included reported severe systemic reactions or anaphylaxis. During the treatment, the active group showed sustained reductions in mean asthma and rhinitis symptom scores when compared with controls to confirm the efficacy and safety of sublingual immunotherapy.
NASA Astrophysics Data System (ADS)
Miao, Connie; Chen, Jerry; Torres Hernandez, Jose; Guhathakurta, Puragra; Jang, Hyerin
2017-01-01
The stark difference between the chaotic internal motion of distant galaxies and the ordered rotation of typical local spiral galaxies suggests that disordered galaxies at high redshifts (i.e., early times in the Universe's history) gradually settle into well ordered disk morphologies with ordered rotation. We have used slit spectra obtained with Keck DEIMOS at four different position angles for 133 distant objects (z ~ 1.0) in the GOODS-N field. The emission lines in the 2D spectra of the galaxies were used to calculate the redshift/velocity at each spatial location. For each slit row, the distribution of flux over velocity was modeled as a Gaussian curve from which we obtained the radial velocity and spread of radial velocity. Rotation curves and velocity dispersions for each galaxy at each slit angle were plotted at these values. We qualitatively classified galaxies as regularly rotating, merging, face-on, or unable to be determined by examining overlays of the rotation curves from the four slit angles. We found that regular rotating galaxies tended to have peak velocity dispersion at the center while mergers had fairly constant velocity dispersions. Face-on galaxies had chaotic and inconsistent velocity dispersions between different slit angles. Regularly rotation galaxies represented 45% of our sample and mergers represented 27%. The relative percentage of galaxies that were either regularly rotating or mergers roughly matched those of the literature. This research was supported by NASA and the National Science Foundation. Most of this work was carried out by high school students working under the auspices of the Science Internship Program at UC Santa Cruz.
Kumar, Deepak; Englesbe, Alexander; Parman, Matthew; ...
2015-11-05
Tabletop reflex discharges in a Penning geometry have many applications including ion sources and eXtreme Ultra-Violet (XUV) sources. The presence of primary electrons accelerated across the cathode sheaths is responsible for the distribution of ion charge states and of the unusually high XUV brightness of these plasmas. Absolutely calibrated space resolved XUV spectra from a table top reflex discharge operating with Al cathodes and Ne gas are presented. The spectra are analyzed with a new and complete model for ion charge distribution in similar reflex discharges. The plasma in the discharge was found to have a density of ~10 18mmore » –3 with a significant fraction >0.01 of fast primary electrons. As a result, the implications of the new model on the ion states achievable in a tabletop reflex plasma discharge are also discussed.« less
Mathematical Fluid Dynamics of Plasma Flow Control over High Speed Wings
2010-12-01
discharges ( DBD ) that fall into a wider class of discharges known as surface barrier discharges (SBD). In 2004-2006 we have improved the fidelity of our...K E\\ exp K B\\ r + 4 T T , I CAp ./or /•: > 0 Jont --, ,/ ^ if y = fe ( , .(• < (). Ev < 0 0 if (/ = 0. i > 0 (2.20) (2.21...obtained data are not sufficient to predict the momentum and heat sources induced by actual DBD -plasma actuators. These sources result from few tens of
Formation of Nitrogen Oxides in an Apokamp-Type Plasma Source
NASA Astrophysics Data System (ADS)
Sosnin, É. A.; Goltsova, P. A.; Panarin, V. A.; Skakun, V. S.; Tarasenko, V. F.; Didenko, M. V.
2017-08-01
Using optical and chemical processes, the composition of the products of decay of the atmospheric-pressure non-equilibrium plasma is determined in a pulsed, high-voltage discharge in the modes of apokampic and corona discharges. It is shown that the products of decay primarily contain nitrogen oxides NO x, and in the mode of the corona discharge - ozone. Potential applications of this source of plasma are discussed with respect to plasma processing of the seeds of agricultural crops.
Propagating intensity disturbances in polar corona as seen from AIA/SDO
NASA Astrophysics Data System (ADS)
Krishna Prasad, S.; Banerjee, D.; Gupta, G. R.
2011-04-01
Context. Polar corona is often explored to find the energy source for the acceleration of the fast solar wind. Earlier observations show omni-presence of quasi-periodic disturbances, traveling outward, which is believed to be caused by the ubiquitous presence of outward propagating waves. These waves, mostly of compressional type, might provide the additional momentum and heat required for the fast solar wind acceleration. It has been conjectured that these disturbances are not due to waves but high speed plasma outflows, which are difficult to distinguish using the current available techniques. Aims: With the unprecedented high spatial and temporal resolution of AIA/SDO, we search for these quasi-periodic disturbances in both plume and interplume regions of the polar corona. We investigate their nature of propagation and search for a plausible interpretation. We also aim to study their multi-thermal nature by using three different coronal passbands of AIA. Methods: We chose several clean plume and interplume structures and studied the time evolution of specific channels by making artificial slits along them. Taking the average across the slits, space-time maps are constructed and then filtration techniques are applied to amplify the low-amplitude oscillations. To suppress the effect of fainter jets, we chose wider slits than usual. Results: In almost all the locations chosen, in both plume and interplume regions we find the presence of propagating quasi-periodic disturbances, of periodicities ranging from 10-30 min. These are clearly seen in two channels and in a few cases out to very large distances (≈250″) off-limb, almost to the edge of the AIA field of view. The propagation speeds are in the range of 100-170 km s-1. The average speeds are different for different passbands and higher in interplume regions. Conclusions: Propagating disturbances are observed, even after removing the effects of jets and are insensitive to changes in slit width. This indicates that a coherent mechanism is involved. In addition, the observed propagation speed varies between the different passpands, implying that these quasi-periodic intensity disturbances are possibly due to magneto-acoustic waves. The propagation speeds in interplume region are higher than in the plume region. Figures 4 and 5 and movies are only available in electronic form at http://www.aanda.org
Takahashi, Kazunori
2012-08-01
A radiofrequency (rf) antenna for helicon plasma thruster experiments is developed and tested using a permanent magnets helicon plasma source immersed in a vacuum chamber. A magnetic nozzle is provided by permanent magnets arrays and an argon plasma is produced by a 13.56 MHz radiofrequency helicon-wave or inductively-coupled discharge. A parasitic discharge outside the source tube is successfully suppressed by covering the rf antenna with a ceramic ring and a grounded shield; a decrease in the ion saturation current of a Langmuir probe located outside the source tube is observed and the ion saturation current on axis increases simultaneously, compared with the case of a standard uncovered rf antenna. It is also demonstrated that the covered antenna can yield stable operation of the source.