Small Animal Models for Evaluating Filovirus Countermeasures.
Banadyga, Logan; Wong, Gary; Qiu, Xiangguo
2018-05-11
The development of novel therapeutics and vaccines to treat or prevent disease caused by filoviruses, such as Ebola and Marburg viruses, depends on the availability of animal models that faithfully recapitulate clinical hallmarks of disease as it is observed in humans. In particular, small animal models (such as mice and guinea pigs) are historically and frequently used for the primary evaluation of antiviral countermeasures, prior to testing in nonhuman primates, which represent the gold-standard filovirus animal model. In the past several years, however, the filovirus field has witnessed the continued refinement of the mouse and guinea pig models of disease, as well as the introduction of the hamster and ferret models. We now have small animal models for most human-pathogenic filoviruses, many of which are susceptible to wild type virus and demonstrate key features of disease, including robust virus replication, coagulopathy, and immune system dysfunction. Although none of these small animal model systems perfectly recapitulates Ebola virus disease or Marburg virus disease on its own, collectively they offer a nearly complete set of tools in which to carry out the preclinical development of novel antiviral drugs.
DOT National Transportation Integrated Search
1977-01-01
In an effort to further the cause of increased safety for those who ride in commercial aircraft, this paper presents a detailed description of the genesis of a small-scale, laboratory test system that utilizes small animals to evaluate the relative t...
A novel small animal model to study the replication of simian foamy virus in vivo.
Blochmann, Rico; Curths, Christoph; Coulibaly, Cheick; Cichutek, Klaus; Kurth, Reinhard; Norley, Stephen; Bannert, Norbert; Fiebig, Uwe
2014-01-05
Preclinical evaluation in a small animal model would help the development of gene therapies and vaccines based on foamy virus vectors. The establishment of persistent, non-pathogenic infection with the prototype foamy virus in mice and rabbits has been described previously. To extend this spectrum of available animal models, hamsters were inoculated with infectious cell supernatant or bioballistically with a foamy virus plasmid. In addition, a novel foamy virus from a rhesus macaque was isolated and characterised genetically. Hamsters and mice were infected with this new SFVmac isolate to evaluate whether hamsters are also susceptible to infection. Both hamsters and mice developed humoral responses to either virus subtype. Virus integration and replication in different animal tissues were analysed by PCR and co-cultivation. The results strongly indicate establishment of a persistent infection in hamsters. These studies provide a further small animal model for studying FV-based vectors in addition to the established models. © 2013 Elsevier Inc. All rights reserved.
Jeong, Jeho; Chen, Qing; Febo, Robert; Yang, Jie; Pham, Hai; Xiong, Jian-Ping; Zanzonico, Pat B.; Deasy, Joseph O.; Humm, John L.; Mageras, Gig S.
2016-01-01
Although spatially precise systems are now available for small-animal irradiations, there are currently limited software tools available for treatment planning for such irradiations. We report on the adaptation, commissioning, and evaluation of a 3-dimensional treatment planning system for use with a small-animal irradiation system. The 225-kV X-ray beam of the X-RAD 225Cx microirradiator (Precision X-Ray) was commissioned using both ion-chamber and radiochromic film for 10 different collimators ranging in field size from 1 mm in diameter to 40 × 40 mm2. A clinical 3-dimensional treatment planning system (Metropolis) developed at our institution was adapted to small-animal irradiation by making it compatible with the dimensions of mice and rats, modeling the microirradiator beam orientations and collimators, and incorporating the measured beam data for dose calculation. Dose calculations in Metropolis were verified by comparison with measurements in phantoms. Treatment plans for irradiation of a tumor-bearing mouse were generated with both the Metropolis and the vendor-supplied software. The calculated beam-on times and the plan evaluation tools were compared. The dose rate at the central axis ranges from 74 to 365 cGy/min depending on the collimator size. Doses calculated with Metropolis agreed with phantom measurements within 3% for all collimators. The beam-on times calculated by Metropolis and the vendor-supplied software agreed within 1% at the isocenter. The modified 3-dimensional treatment planning system provides better visualization of the relationship between the X-ray beams and the small-animal anatomy as well as more complete dosimetric information on target tissues and organs at risk. It thereby enhances the potential of image-guided microirradiator systems for evaluation of dose–response relationships and for preclinical experimentation generally. PMID:25948321
Clemente, Miriam; Rey, Beatriz; Rodriguez-Pujadas, Aina; Breton-Lopez, Juani; Barros-Loscertales, Alfonso; Baños, Rosa M; Botella, Cristina; Alcañiz, Mariano; Avila, Cesar
2014-06-27
To date, still images or videos of real animals have been used in functional magnetic resonance imaging protocols to evaluate the brain activations associated with small animals' phobia. The objective of our study was to evaluate the brain activations associated with small animals' phobia through the use of virtual environments. This context will have the added benefit of allowing the subject to move and interact with the environment, giving the subject the illusion of being there. We have analyzed the brain activation in a group of phobic people while they navigated in a virtual environment that included the small animals that were the object of their phobia. We have found brain activation mainly in the left occipital inferior lobe (P<.05 corrected, cluster size=36), related to the enhanced visual attention to the phobic stimuli; and in the superior frontal gyrus (P<.005 uncorrected, cluster size=13), which is an area that has been previously related to the feeling of self-awareness. In our opinion, these results demonstrate that virtual stimulus can enhance brain activations consistent with previous studies with still images, but in an environment closer to the real situation the subject would face in their daily lives.
NASA Astrophysics Data System (ADS)
Boudousq, V.; Bordy, T.; Gonon, G.; Dinten, J. M.
2005-04-01
The LEXXOS (DMS, Montpellier, France) is the first axial and total body cone beam bone densitometer using a 2D digital radiographic detector. Technical principles and performances for BMD measurements have been presented in previous papers. Bone densitometers are also used on small animals for drug development. In this paper, we show how the LEXXOS system can be adapted to small animals examinations, and its performances are evaluated. At first, in order to take advantage of the whole area of the digital flat panel X-ray detector, the geometrical configuration has been adapted. Secondly, as small animals present low BMD, a specific dual energy calibration has been defined. This adapted system has then been evaluated on two sets of mice: six reference mice and six ovariectomized mice. Each month, these two populations have been examined and the total body BMD has been measured. This evaluation has shown that the right order of BMD magnitude has been obtained and, as expected, BMD increases on the two sets until age of puberty and after this period, decreases significantly for the ovariectomized set. Moreover, the bone image obtained by dual energy processing on LEXXOS presents a radiographic image quality providing with useful complementary information on bone morphometry and architecture.
Hrycushko, Brian A; Bing, Chenchen; Futch, Cecil; Wodzak, Michelle; Stojadinovic, Strahinja; Medin, Paul M; Chopra, Rajiv
2017-08-01
The protective effects of induced or even accidental hypothermia on the human body are widespread with several medical uses currently under active research. In vitro experiments using human cell lines have shown hypothermia provides a radioprotective effect that becomes more pronounced at large, single-fraction doses common to stereotactic body radiotherapy (SBRT) and stereotactic radiosurgery (SRS) treatments. This work describes the development of a system to evaluate local hypothermia for a radioprotective effect of the rat rectum during a large dose of radiation relevant to prostate SBRT. This includes the evaluation of a 3D-printed small animal rectal cooling device and the integration with a small animal irradiator. A 3-cm long, dual-lumen rectal temperature control apparatus (RTCA) was designed in SOLIDWORKS CAD for 3D printing. The RTCA was capable of recirculating flow in a device small enough for insertion into the rat rectum, with a metal support rod for strength as well as visibility during radiation treatment planning. The outer walls of the RTCA comprised of thin heat shrink plastic, achieving efficient heat transfer into adjacent tissues. Following leak-proof testing, fiber optic temperature probes were used to evaluate the temperature over time when placed adjacent to the cooling device within the rat rectum. MRI thermometry characterized the relative temperature distribution in concentric ROIs surrounding the probe. Integration with an image-guided small animal irradiator and associated treatment planning system included evaluation for imaging artifacts and effect of brass tubing on dose calculation. The rectal temperature adjacent to the cooling device decreased from body temperature to 15°C within 10-20 min from device insertion and was maintained at 15 ± 3°C during active cooling for the evaluated time of one hour. MR thermometry revealed a steep temperature gradient with increasing distance from the cooling device with the desired temperature range maintained within the surrounding few millimeters. A 3D-printed rectal cooling device was fabricated for the purpose of inducing local hypothermia in the rat rectum. The RTCA was simply integrated with an image-guided small animal irradiator and Monte Carlo-based treatment planning system to facilitate an in vivo investigation of the radioprotective effect of hypothermia for late rectal toxicity following a single large dose of radiation. © 2017 American Association of Physicists in Medicine.
PEGDA hydrogels as a replacement for animal tissues in mucoadhesion testing.
Eshel-Green, Tal; Eliyahu, Shaked; Avidan-Shlomovich, Shlomit; Bianco-Peled, Havazelet
2016-06-15
Utilization of animal parts in ex-vivo mucoadhesion assays is a common approach that presents many difficulties due to animal rights issues and large variance between animals. This study examines the suitability of two PEGDA (poly(ethylene glycol) diacrylate) based hydrogels to serve as tissue mimetics for mucoadhesion evaluation. One hydrogel, termed PEGDA-QT, was composed of pentaerythritol tetrakis (3-mercaptopropionate) and PEG and contained free thiol groups mimicking those found in natural mucosa. The other hydrogel was formed by UV (ultraviolet) curing of PEGDA and mimicked the mechanical property of mucosa but not its chemical constitute. When ranking different first generation mucoadhesive polymers using a tensile assay, both hydrogels showed good agreement with the ranking achieved for porcine small intestine. However, only PEGDA-QT and porcine small intestine shared a similar displacement curve. The same ranking for PEGDA-QT and porcine small intestine was also observed when comparing a second-generation mucoadhesive polymer, thiolated alginate, to native alginate. Our findings suggest that PEGDA-QT could serve as a replacement for porcine small intestine in both mucoadhesion evaluations using a tensile machine and the flow-through method for first and second-generation mucoadhesive polymers. Copyright © 2016 Elsevier B.V. All rights reserved.
The evaluation of 6 and 18 MeV electron beams for small animal irradiation
NASA Astrophysics Data System (ADS)
Chao, T. C.; Chen, A. M.; Tu, S. J.; Tung, C. J.; Hong, J. H.; Lee, C. C.
2009-10-01
A small animal irradiator is critical for providing optimal radiation dose distributions for pre-clinical animal studies. This paper focuses on the evaluation of using 6 or 18 MeV electron beams as small animal irradiators. Compared with all other prototypes which use photons to irradiate small animals, an electron irradiator has many advantages in its shallow dose distribution. Two major approaches including simulation and measurement were used to evaluate the feasibility of applying electron beams in animal irradiation. These simulations and measurements were taken in three different fields (a 6 cm × 6 cm square field, and 4 mm and 30 mm diameter circular fields) and with two different energies (6 MeV and 18 MeV). A PTW Semiflex chamber in a PTW-MP3 water tank, a PTW Markus chamber type 23343, a PTW diamond detector type 60003 and KODAK XV films were used to measure PDDs, lateral beam profiles and output factors for either optimizing parameters of Monte Carlo simulation or to verify Monte Carlo simulation in small fields. Results show good agreement for comparisons of percentage depth doses (<=2.5% for 6 MeV e; <=1.8% for 18 MeV e) and profiles (FWHM <= 0.5 mm) between simulations and measurements on the 6 cm field. Greater deviation can be observed in the 4 mm field, which is mainly caused by the partial volume effects of the detectors. The FWHM of the profiles for the 18 MeV electron beam is 32.6 mm in the 30 mm field, and 4.7 mm in the 4 mm field at d90. It will take 1-13 min to complete one irradiation of 5-10 Gy. In addition, two different digital phantoms were also constructed, including a homogeneous cylindrical water phantom and a CT-based heterogeneous mouse phantom, and were implemented into Monte Carlo to simulate dose distribution with different electron irradiations.
Small-Animal Molecular Imaging for Preclinical Cancer Research: .μPET and μ.SPECT.
Cuccurullo, Vincenzo; Di Stasio, Giuseppe D; Schillirò, Maria L; Mansi, Luigi
2016-01-01
Due to different sizes of humans and rodents, the performance of clinical imaging devices is not enough for a scientifically reliable evaluation in mice and rats; therefore dedicated small-animal systems with a much higher sensitivity and spatial resolution, compared to the ones used in humans, are required. Smallanimal imaging represents a cutting-edge research method able to approach an enormous variety of pathologies in which animal models of disease may be used to elucidate the mechanisms underlying the human condition and/or to allow a translational pharmacological (or other) evaluation of therapeutic tools. Molecular imaging, avoiding animal sacrifice, permits repetitive (i.e. longitudinal) studies on the same animal which becomes its own control. In this way also the over time evaluation of disease progression or of the treatment response is enabled. Many different rodent models have been applied to study almost all kind of human pathologies or to experiment a wide series of drugs and/or other therapeutic instruments. In particular, relevant information has been achieved in oncology by in vivo neoplastic phenotypes, obtained through procedures such as subcutaneous tumor grafts, surgical transplantation of solid tumor, orthotopic injection of tumor cells into specific organs/sites of interest, genetic modification of animals to promote tumor-genesis; in this way traditional or innovative treatments, also including gene therapy, of animals with a cancer induced by a known carcinogen may be experimented. Each model has its own disadvantage but, comparing different studies, it is possible to achieve a panoramic and therefore substantially reliable view on the specific subject. Small-animal molecular imaging has become an invaluable component of modern biomedical research that will gain probably an increasingly important role in the next few years.
USDA-ARS?s Scientific Manuscript database
Numerous modeling and field studies have evaluated the effectiveness of vegetative treatment systems in treating runoff from animal feeding operations; however, none have evaluated the effectiveness of vegetative treatment areas (VTA’s) receiving direct runoff from small swine operations during natu...
Boller, Manuel; Fletcher, Daniel J
2012-06-01
To describe the methodology used by the Reassessment Campaign on Veterinary Resuscitation (RECOVER) to evaluate the scientific evidence relevant to small animal CPR and to compose consensus-based clinical CPR guidelines for dogs and cats. This report is part of a series of 7 articles on the RECOVER evidence and knowledge gap analysis and consensus-based small animal CPR guidelines. It describes the organizational structure of RECOVER, the evaluation process employed, consisting of standardized literature searches, the analysis of relevant articles according to study design, species and predefined quality markers, and the drafting of clinical CPR guidelines based on these data. Therefore, this article serves as the methodology section for the subsequent 6 RECOVER articles. Academia, referral practice. RECOVER is a collaborative initiative that systematically evaluated the evidence on 74 topics relevant to small animal CPR and generated 101 clinical CPR guidelines from this analysis. All primary contributors were veterinary specialists, approximately evenly split between academic institutions and private referral practices. The evidence evaluation and guideline drafting processes were conducted according to a predefined sequence of steps designed to reduce bias and increase the repeatability of the findings, including multiple levels of review, culminating in a consensus process. Many knowledge gaps were identified that will allow prioritization of research efforts in veterinary CPR. Collaborative systematic evidence review is organizationally challenging but feasible and effective in veterinary medicine. More experience is needed to refine the process. © Veterinary Emergency and Critical Care Society 2012.
Ramme, Austin J; Voss, Kevin; Lesporis, Jurinus; Lendhey, Matin S; Coughlin, Thomas R; Strauss, Eric J; Kennedy, Oran D
2017-05-01
MicroCT imaging allows for noninvasive microstructural evaluation of mineralized bone tissue, and is essential in studies of small animal models of bone and joint diseases. Automatic segmentation and evaluation of articular surfaces is challenging. Here, we present a novel method to create knee joint surface models, for the evaluation of PTOA-related joint changes in the rat using an atlas-based diffeomorphic registration to automatically isolate bone from surrounding tissues. As validation, two independent raters manually segment datasets and the resulting segmentations were compared to our novel automatic segmentation process. Data were evaluated using label map volumes, overlap metrics, Euclidean distance mapping, and a time trial. Intraclass correlation coefficients were calculated to compare methods, and were greater than 0.90. Total overlap, union overlap, and mean overlap were calculated to compare the automatic and manual methods and ranged from 0.85 to 0.99. A Euclidean distance comparison was also performed and showed no measurable difference between manual and automatic segmentations. Furthermore, our new method was 18 times faster than manual segmentation. Overall, this study describes a reliable, accurate, and automatic segmentation method for mineralized knee structures from microCT images, and will allow for efficient assessment of bony changes in small animal models of PTOA.
Hand hygiene practices of veterinary support staff in small animal private practice.
Nakamura, R K; Tompkins, E; Braasch, E L; Martinez, J G; Bianco, D
2012-03-01
To evaluate the hand hygiene (HH) practices among veterinary technicians (VT) and veterinary support staff (VSS) in small animal private practice. This was a prospective questionnaire-based study involving 182 VT and VSS from 18 small animal hospitals in the USA. Questions asked included gender, number of animals handled per work shift, frequency of hand washing, reason for not washing more frequently, most common available hand washing agent, education regarding the importance of HH and frequency of ring wearing. Less than half of the respondents [76 of 182 (41·7%)] reported washing their hands regularly between handling patients and 154 of 182 (85·6%) believed they should have washed more frequently. The most commonly employed HH agent was hand soap [154 of 182 (84·6%)] and the most common reason cited for not washing more frequently was being too busy [132 of 182 (72·5%)]. Only 96 of 182 (52·7%) respondents were educated by doctors at their hospital regarding the importance of HH. The HH practices among VT and VSS in small animal private practice is poor. Hand soap was the most commonly employed agent among respondents in this study. Education of VT and VSS regarding the importance of HH requires improvement. © 2012 British Small Animal Veterinary Association.
Aide, Nicolas; Louis, Marie-Hélène; Dutoit, Soizic; Labiche, Alexandre; Lemoisson, Edwige; Briand, Mélanie; Nataf, Valérie; Poulain, Laurent; Gauduchon, Pascal; Talbot, Jean-Noël; Montravers, Françoise
2007-10-01
To evaluate the accuracy of semi-quantitative small-animal PET data, uncorrected for attenuation, and then of the same semi-quantitative data corrected by means of recovery coefficients (RCs) based on phantom studies. A phantom containing six fillable spheres (diameter range: 4.4-14 mm) was filled with an 18F-FDG solution (spheres/background activity=10.1, 5.1 and 2.5). RCs, defined as measured activity/expected activity, were calculated. Nude rats harbouring tumours (n=50) were imaged after injection of 18F-FDG and sacrificed. The standardized uptake value (SUV) in tumours was determined with small-animal PET and compared to ex-vivo counting (ex-vivo SUV). Small-animal PET SUVs were corrected with RCs based on the greatest tumour diameter. Tumour proliferation was assessed with cyclin A immunostaining and correlated to the SUV. RCs ranged from 0.33 for the smallest sphere to 0.72 for the largest. A sigmoidal correlation was found between RCs and sphere diameters (r(2)=0.99). Small-animal PET SUVs were well correlated with ex-vivo SUVs (y=0.48x-0.2; r(2)=0.71) and the use of RCs based on the greatest tumour diameter significantly improved regression (y=0.84x-0.81; r(2)=0.77), except for tumours with important necrosis. Similar results were obtained without sacrificing animals, by using PET images to estimate tumour dimensions. RC-based corrections improved correlation between small-animal PET SUVs and tumour proliferation (uncorrected data: Rho=0.79; corrected data: Rho=0.83). Recovery correction significantly improves both accuracy of small-animal PET semi-quantitative data in rat studies and their correlation with tumour proliferation, except for largely necrotic tumours.
Specific issues in small animal dosimetry and irradiator calibration
Yoshizumi, Terry; Brady, Samuel L.; Robbins, Mike E.; Bourland, J. Daniel
2013-01-01
Purpose In response to the increased risk of radiological terrorist attack, a network of Centers for Medical Countermeasures against Radiation (CMCR) has been established in the United States, focusing on evaluating animal model responses to uniform, relatively homogenous whole- or partial-body radiation exposures at relatively high dose rates. The success of such studies is dependent not only on robust animal models but on accurate and reproducible dosimetry within and across CMCR. To address this issue, the Education and Training Core of the Duke University School of Medicine CMCR organised a one-day workshop on small animal dosimetry. Topics included accuracy in animal dosimetry accuracy, characteristics and differences of cesium-137 and X-ray irradiators, methods for dose measurement, and design of experimental irradiation geometries for uniform dose distributions. This paper summarises the information presented and discussed. Conclusions Without ensuring accurate and reproducible dosimetry the development and assessment of the efficacy of putative countermeasures will not prove successful. Radiation physics support is needed, but is often the weakest link in the small animal dosimetry chain. We recommend: (i) A user training program for new irradiator users, (ii) subsequent training updates, and (iii) the establishment of a national small animal dosimetry center for all CMCR members. PMID:21961967
Implantable telemetry for small animals
NASA Astrophysics Data System (ADS)
1982-03-01
A series of totally implantable telemetry devices for use in measuring deep body parameters in small animals were developed. Under a collaborative agreement with NASA, several of these systems; the continuous wave Doppler ultrasonic flowmeter, the multichannel telemetry system, and the inductively-powered dual channel cardiac pacer were evaluated in a series of ten mongrel dogs (15 to 20 kg.). These systems were used to measure ascending aortic and coronary blood flow, aortic pressure, and subcutaneous EKG.
Implantable telemetry for small animals
NASA Technical Reports Server (NTRS)
1982-01-01
A series of totally implantable telemetry devices for use in measuring deep body parameters in small animals were developed. Under a collaborative agreement with NASA, several of these systems; the continuous wave Doppler ultrasonic flowmeter, the multichannel telemetry system, and the inductively-powered dual channel cardiac pacer were evaluated in a series of ten mongrel dogs (15 to 20 kg.). These systems were used to measure ascending aortic and coronary blood flow, aortic pressure, and subcutaneous EKG.
Lasnon, Charline; Quak, Elske; Briand, Mélanie; Gu, Zheng; Louis, Marie-Hélène; Aide, Nicolas
2013-01-17
The use of iodinated contrast media in small-animal positron emission tomography (PET)/computed tomography (CT) could improve anatomic referencing and tumor delineation but may introduce inaccuracies in the attenuation correction of the PET images. This study evaluated the diagnostic performance and accuracy of quantitative values in contrast-enhanced small-animal PET/CT (CEPET/CT) as compared to unenhanced small animal PET/CT (UEPET/CT). Firstly, a NEMA NU 4-2008 phantom (filled with 18F-FDG or 18F-FDG plus contrast media) and a homemade phantom, mimicking an abdominal tumor surrounded by water or contrast media, were used to evaluate the impact of iodinated contrast media on the image quality parameters and accuracy of quantitative values for a pertinent-sized target. Secondly, two studies in 22 abdominal tumor-bearing mice and rats were performed. The first animal experiment studied the impact of a dual-contrast media protocol, comprising the intravenous injection of a long-lasting contrast agent mixed with 18F-FDG and the intraperitoneal injection of contrast media, on tumor delineation and the accuracy of quantitative values. The second animal experiment compared the diagnostic performance and quantitative values of CEPET/CT versus UEPET/CT by sacrificing the animals after the tracer uptake period and imaging them before and after intraperitoneal injection of contrast media. There was minimal impact on IQ parameters (%SDunif and spillover ratios in air and water) when the NEMA NU 4-2008 phantom was filled with 18F-FDG plus contrast media. In the homemade phantom, measured activity was similar to true activity (-0.02%) and overestimated by 10.30% when vials were surrounded by water or by an iodine solution, respectively. The first animal experiment showed excellent tumor delineation and a good correlation between small-animal (SA)-PET and ex vivo quantification (r2 = 0.87, P < 0.0001). The second animal experiment showed a good correlation between CEPET/CT and UEPET/CT quantitative values (r2 = 0.99, P < 0.0001). Receiver operating characteristic analysis demonstrated better diagnostic accuracy of CEPET/CT versus UEPET/CT (senior researcher, area under the curve (AUC) 0.96 versus 0.77, P = 0.004; junior researcher, AUC 0.78 versus 0.58, P = 0.004). The use of iodinated contrast media for small-animal PET imaging significantly improves tumor delineation and diagnostic performance, without significant alteration of SA-PET quantitative accuracy and NEMA NU 4-2008 IQ parameters.
Bohndiek, Sarah E.; Bodapati, Sandhya; Van De Sompel, Dominique; Kothapalli, Sri-Rajasekhar; Gambhir, Sanjiv S.
2013-01-01
Photoacoustic imaging combines the high contrast of optical imaging with the spatial resolution and penetration depth of ultrasound. This technique holds tremendous potential for imaging in small animals and importantly, is clinically translatable. At present, there is no accepted standard physical phantom that can be used to provide routine quality control and performance evaluation of photoacoustic imaging instruments. With the growing popularity of the technique and the advent of several commercial small animal imaging systems, it is important to develop a strategy for assessment of such instruments. Here, we developed a protocol for fabrication of physical phantoms for photoacoustic imaging from polyvinyl chloride plastisol (PVCP). Using this material, we designed and constructed a range of phantoms by tuning the optical properties of the background matrix and embedding spherical absorbing targets of the same material at different depths. We created specific designs to enable: routine quality control; the testing of robustness of photoacoustic signals as a function of background; and the evaluation of the maximum imaging depth available. Furthermore, we demonstrated that we could, for the first time, evaluate two small animal photoacoustic imaging systems with distinctly different light delivery, ultrasound imaging geometries and center frequencies, using stable physical phantoms and directly compare the results from both systems. PMID:24086557
Advances in Small Animal Imaging Systems
NASA Astrophysics Data System (ADS)
Loudos, George K.
2007-11-01
The rapid growth in genetics and molecular biology combined with the development of techniques for genetically engineering small animals has led to an increased interest in in vivo laboratory animal imaging during the past few years. For this purpose, new instrumentation, data acquisition strategies, and image processing and reconstruction techniques are being developed, researched and evaluated. The aim of this article is to give a short overview of the state of the art technologies for high resolution and high sensitivity molecular imaging techniques, primarily positron emission tomography (PET) and single photon emission computed tomography (SPECT). The basic needs of small animal imaging will be described. The evolution in instrumentation in the past two decades, as well as the commercially available systems will be overviewed. Finally, the new trends in detector technology and preliminary results from challenging applications will be presented. For more details a number of references are provided.
Zhou, Zhiping; Ho, Sharon L; Singh, Ranjodh; Pisapia, David J; Souweidane, Mark M
2015-04-01
Diffuse intrinsic pontine gliomas (DIPGs) are inoperable and lethal high-grade gliomas lacking definitive therapy. Platelet-derived growth factor receptor (PDGFR) and its downstream signaling molecules are the most commonly overexpressed oncogenes in DIPG. This study tested the effective concentration of PDGFR pathway inhibitors in cell culture and then toxicity of these small-molecule kinase inhibitors delivered to the mouse brainstem via convection-enhanced delivery (CED) for potential clinical application. Effective concentrations of small-molecule kinase inhibitors were first established in cell culture from a mouse brainstem glioma model. Sixteen mice underwent CED, a local drug delivery technique, of saline or of single and multidrug combinations of dasatinib (2 M), everolimus (20 M), and perifosine (0.63 mM) in the pons. Animals were kept alive for 3 days following the completion of infusion. No animals displayed any immediate or delayed neurological deficits postoperatively. Histological analysis revealed edema, microgliosis, acute inflammation, and/or axonal injury in the experimental animals consistent with mild acute drug toxicity. Brainstem CED of small-molecule kinase inhibitors in the mouse did not cause serious acute toxicities. Future studies will be necessary to evaluate longer-term safety to prepare for potential clinical application.
Biological X-ray irradiator characterization for use with small animals and cells.
Bruno, A Colello; Mazaro, S J; Amaral, L L; Rego, E M; Oliveira, H F; Pavoni, J F
2017-03-02
This study presents the characterization of an X-ray irradiator through dosimetric tests, which confirms the actual dose rate that small animals and cells will be exposed to during radiobiological experiments. We evaluated the linearity, consistency, repeatability, and dose distribution in the positions in which the animals or cells are placed during irradiation. In addition, we evaluated the performance of the X-ray tube (voltage and tube operating current), the radiometric survey (leakage radiation) and safety devices. The irradiator default setting was established as 160 kV and 25 mA. Tests showed that the dose rate was linear overtime (R2=1) and remained stable for long (constant) and short (repeatability) intervals between readings. The mean dose rate inside the animal cages was 1.27±0.06 Gy/min with a uniform beam of 95.40% (above the minimum threshold guaranteed by the manufacturer). The mean dose rate inside the cell plates was 0.92±0.19 Gy/min. The dose rate dependence with tube voltage and current presented a quadratic and linear relationship, respectively. There was no observed mechanical failure during evaluation of the irradiator safety devices and the radiometric survey obtained a maximum ambient equivalent dose rate of 0.26 mSv/h, which exempts it from the radiological protection requirements of the International Atomic Energy Agency. The irradiator characterization enables us to perform radiobiological experiments, and assists or even replaces traditional therapy equipment (e.g., linear accelerators) for cells and small animal irradiation, especially in early research stages.
Aerophagia induced by the nasal obstruction on experimental animals.
Nakajima, K; Ohi, G
1977-04-01
The excessive accumulation of gas in the gastrointestinal tracts was invariably induced on experimental animals (mice, rats, guinea pigs, hamsters and rabbits) by simply obstructing nasal passages. The analysis of the gas showed the almost identical composition to the ambient air or flutus which was largely due to swallowed air. Also the numerous small foams were found on and underneath the epithelial lining of small intestine. The pathological evaluation was done both macroscopically and microscopically. Dying animals after nasal obstruction showed hemorrhagic and necrotic changes in the jejunum and ileum. This observation may cast some light to the pathogenesis of necrotizing enterocolitis in human neonatal.
NASA Technical Reports Server (NTRS)
Guthrie, R. K.
1976-01-01
The effects of increased concentrations of PSEUDOMONAS AERUGINOSA AND STAPHYLOCOCCUS in the total bacterial flora of small animals exposed to simulated spacecraft environments were evaluated. Tests to detect changes in infectivity, effects of antibiotic treatments, immune responses to bacterial antigens, and effectiveness of immune responses in the experimental environment were conducted. The most significant results appear to be the differences in immune responses at simulated altitudes and the production of infection in the presence of a specific antibody.
Real-time 3D motion tracking for small animal brain PET
NASA Astrophysics Data System (ADS)
Kyme, A. Z.; Zhou, V. W.; Meikle, S. R.; Fulton, R. R.
2008-05-01
High-resolution positron emission tomography (PET) imaging of conscious, unrestrained laboratory animals presents many challenges. Some form of motion correction will normally be necessary to avoid motion artefacts in the reconstruction. The aim of the current work was to develop and evaluate a motion tracking system potentially suitable for use in small animal PET. This system is based on the commercially available stereo-optical MicronTracker S60 which we have integrated with a Siemens Focus-220 microPET scanner. We present measured performance limits of the tracker and the technical details of our implementation, including calibration and synchronization of the system. A phantom study demonstrating motion tracking and correction was also performed. The system can be calibrated with sub-millimetre accuracy, and small lightweight markers can be constructed to provide accurate 3D motion data. A marked reduction in motion artefacts was demonstrated in the phantom study. The techniques and results described here represent a step towards a practical method for rigid-body motion correction in small animal PET. There is scope to achieve further improvements in the accuracy of synchronization and pose measurements in future work.
Stress assessment in small ruminants kept on city farms in southern Germany.
Schilling, Anna-Katarina; Reese, Sven; Palme, Rupert; Erhard, Michael; Wöhr, Anna-Caroline
2015-01-01
Sheep and goats are frequently used in nonhuman animal-assisted activities on city farms. There are few data available on this type of usage of small ruminants. Health evaluations, behavioral observations (feeding, resting, comfort, explorative and social behaviors), behavioral tests (human approach tests and touch test), and measurements of fecal cortisol metabolites and heart rate were performed to assess stress levels in 25 sheep and 32 goats on 7 city farms and 2 activity playgrounds in Germany. No evidence was found that the animals suffered from major distress. Health evaluations, behavioral observations, and behavioral tests proved to be the methods of stress assessment most suitable for routine on-farm checks in these settings.
Development of a Body Shield for Small Animal PET System to Reduce Random and Scatter Coincidences
NASA Astrophysics Data System (ADS)
Wada, Yasuhiro; Yamamoto, Seiichi; Watanabe, Yasuyoshi
2015-02-01
For small animal positron emission tomography (PET) research using high radioactivity, such as dynamic studies, the resulting high random coincidence rate of the system degrades image quality. The random coincidence rate is increased not only by the gamma photons from inside the axial-field-of-view (axial-FOV) of the PET system but also by those from outside the axial-FOV. For brain imaging in small animal studies, significant interference is observed from gamma photons emitted from the body. Single gamma photons from the body enter the axial-FOV and increase the random and scatter coincidences. Shielding against the gamma photons from outside the axial-FOV would improve the image quality. For this purpose, we developed a body shield for a small animal PET system, the microPET Primate 4-ring system, and evaluated its performance. The body shield is made of 9-mm-thick lead and it surrounds most of a rat's body. We evaluated the effectiveness of the body shield using a head phantom and a body phantom with a radioactivity concentration ratio of 1:2 and a maximum total activity of approximately 250 MBq. The random coincidence rate was dramatically decreased to 1/10, and the noise equivalent count rate (NECR) was increased 6 times with an activity of 7 MBq in the head phantom. The true count rate was increased to 35% due to the decrease in system deadtime. The average scatter fraction was decreased to 1/2.5 with the body shield. Count rate measurements of rat were also conducted with an injection activity of approximately 25 MBq of [C-11]N,N-dimethyl-2-(2-amino-4-cyanophenylthio) benzylamine ([C-11]DASB) and approximately 70 and 310 MBq of 2-deoxy-2-(F-18)fluoro-D-glucose ([F-18]FDG). Using the body shield, [F-18]FDG images of rats were improved by increasing the amount of radioactivity injected. The body shield designed for small animal PET systems is a promising tool for improving image quality and quantitation accuracy in small animal molecular imaging research.
Performance Evaluation of a PEM Scanner Using the NEMA NU 4—2008 Small Animal PET Standards
NASA Astrophysics Data System (ADS)
Luo, Weidong; Anashkin, Edward; Matthews, Christopher G.
2010-02-01
The recently published NEMA NU 4-2008 Standards has been specially designed for evaluating the performance of small animal PET scanners used in preclinical applications. In this paper, we report on the NU 4 performance of a clinical positron emission mammography (PEM) system. Since there are no PEM specific performance test protocols available, and the NU 2 protocol (intended for whole-body PET scanners) cannot be applied without modification due to the compact design of the PEM scanner, we decided to evaluate the NU 4 Standards as an alternative. We obtained the following results: Trans-axial spatial resolution 1.8 mm FWHM for high resolution reconstruction mode and 2.4 mm FWHM for standard resolution reconstruction mode with no significant variation within the field of view. The total system sensitivity was 0.16 cps/Bq. In image quality testing, the uniformity was found to be 3.9% STD at the standard resolution mode and 5.6% at the high resolution mode when measured with a 34 mm paddle separation. The NEMA NU 4-2008 Standards were found to be a practicable tool to evaluate the performance of the PEM scanner after some modifications to address the specifics of its detector configuration. Furthermore, the PEM scanner's in-plane spatial resolution was comparable to other small animal PET scanners with good image quality.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hrycushko, B; Medin, P
Purpose: The incidence of peripheral neuropathy has risen with increased utilization of SAbR. There is no consensus regarding the dose-tolerance of the peripheral nervous system. In 2015, we commenced an investigation to test the hypotheses that single-session irradiation to the pig spinal nerves exhibit a similar dose-tolerance as that of the spinal cord and that a dose-length effect exists. This work evaluates the direct application of small animal NTCP models to both large animal spinal cord and preliminary peripheral nerve data. Methods: To date, 16 of 25 Yucatan minipigs have received single-session SAbR to a 1.5cm length and 4 ofmore » 25 have received irradiation to a 0.5cm length of left-sided C6-C8 spinal nerves. Toxicity related gait change has been observed in 13 animals (9 from the long length group and 4 from the short). This preliminary data is overlaid on several dose-response models which have been fit to rodent spinal cord tolerance experiments. Model parameters define a toxicity profile between a completely serial or parallel behaving organ. Adequacy of model application, including how length effects are handled, to published minipig spinal cord dose-response data and to preliminary peripheral nerve response data was evaluated through residual analysis. Results: No rodent-derived dose-response models were directly applicable to all pig data for the different lengths irradiated. Several models fit the long-length irradiated spinal cord data well, with the more serial-like models fitting best. Preliminary data on the short-length irradiation suggests no length effect exists, disproving our hypothesis. Conclusion: Direct application of small-animal NTCP models to pig data suggests dose-length effect predictions from small animal data may not translate clinically. However, the small animal models used have not considered dose heterogeneity and it is expected that including the low-to-mid dose levels in the penumbral region will improve this match. This work was funded by the Cancer Prevention Research Institute of Texas (CPRIT).« less
Characterization of a high-purity germanium detector for small-animal SPECT
Johnson, Lindsay C; Campbell, Desmond L; Hull, Ethan L; Peterson, Todd E
2011-01-01
We present an initial evaluation of a mechanically-cooled, high-purity germanium double-sided strip detector as a potential gamma camera for small-animal SPECT. It is 90 mm in diameter and 10 mm thick with two sets of 16 orthogonal strips that have a 4.5 mm width with a 5 mm pitch. We found an energy resolution of 0.96% at 140 keV, an intrinsic efficiency of 43.3% at 122 keV and a FWHM spatial resolution of approximately 1.5 mm. We demonstrated depth-of-interaction estimation capability through comparison of pinhole acquisitions with a point source on and off axis. Finally, a flood-corrected-flood image exhibited a strip-level uniformity of less than 1%. This high-purity germanium offers many desirable properties for small-animal SPECT. PMID:21852723
Characterization of a high-purity germanium detector for small-animal SPECT.
Johnson, Lindsay C; Campbell, Desmond L; Hull, Ethan L; Peterson, Todd E
2011-09-21
We present an initial evaluation of a mechanically cooled, high-purity germanium double-sided strip detector as a potential gamma camera for small-animal SPECT. It is 90 mm in diameter and 10 mm thick with two sets of 16 orthogonal strips that have a 4.5 mm width with a 5 mm pitch. We found an energy resolution of 0.96% at 140 keV, an intrinsic efficiency of 43.3% at 122 keV and a FWHM spatial resolution of approximately 1.5 mm. We demonstrated depth-of-interaction estimation capability through comparison of pinhole acquisitions with a point source on and off axes. Finally, a flood-corrected flood image exhibited a strip-level uniformity of less than 1%. This high-purity germanium offers many desirable properties for small-animal SPECT.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, S; Kim, K; Jung, H
Purpose: The small animal irradiator has been used with small animals to optimize new radiation therapy as preclinical studies. The small animal was irradiated by whole- or partial-body exposure. In this study, the dosimetric characterizations of small animal irradiator were carried out in small field using Radiochromic films Material & Methods: The study was performed in commercial animal irradiator (XRAD-320, Precision x-ray Inc, North Brantford) with Radiochromic films (EBT2, Ashland Inc, Covington). The calibration curve was generated between delivery dose and optical density (red channel) and the films were scanned by and Epson 1000XL scanner (Epson America Inc., Long Beach,more » CA).We evaluated dosimetric characterization of irradiator using various filter supported by manufacturer in 260 kV. The various filters were F1 (2.0mm Aluminum (HVL = about 1.0mm Cu) and F2 (0.75mm Tin + 0.25mm Copper + 1.5mm Aluminum (HVL = about 3.7mm Cu). According to collimator size (3, 5, 7, 10 mm, we calculated percentage depth dose (PDD) and the surface –source distance(SSD) was 17.3 cm considering dose rate. Results: The films were irradiated in 260 kV, 10mA and we increased exposure time 5sec. intervals from 5sec. to 120sec. The calibration curve of films was fitted with cubic function. The correlation between optical density and dose was Y=0.1405 X{sup 3}−2.916 X{sup 2}+25.566 x+2.238 (R{sup 2}=0.994). Based on the calibration curve, we calculated PDD in various filters depending on collimator size. When compared PDD of specific depth (3mm) considering animal size, the difference by collimator size was 4.50% in free filter and F1 was 1.53% and F2 was within 2.17%. Conclusion: We calculated PDD curve in small animal irradiator depending on the collimator size and the kind of filter using the radiochromic films. The various PDD curve was acquired and it was possible to irradiate various dose using these curve.« less
Establishing a small animal model for evaluating protective immunity against mumps virus.
Pickar, Adrian; Xu, Pei; Elson, Andrew; Zengel, James; Sauder, Christian; Rubin, Steve; He, Biao
2017-01-01
Although mumps vaccines have been used for several decades, protective immune correlates have not been defined. Recently, mumps outbreaks have occurred in vaccinated populations. To better understand the causes of the outbreaks and to develop means to control outbreaks in mumps vaccine immunized populations, defining protective immune correlates will be critical. Unfortunately, no small animal model for assessing mumps immunity exists. In this study, we evaluated use of type I interferon (IFN) alpha/beta receptor knockout mice (IFN-α/βR-/-) for such a model. We found these mice to be susceptible to mumps virus administered intranasally and intracranially. Passive transfer of purified IgG from immunized mice protected naïve mice from mumps virus infection, confirming the role of antibody in protection and demonstrating the potential for this model to evaluate mumps immunity.
Anti-rotaviral effects of Glycyrrhiza uralensis extract in piglets with rotavirus diarrhea
2012-01-01
Background Since rotavirus is one of the leading pathogens that cause severe gastroenteritis and represents a serious threat to human and animal health, researchers have been searching for cheap, safe, and effective anti-rotaviral drugs. There is a widespread of interest in using natural products as antiviral agents, and among them, licorice derived from Glycyrrhiza spp. has exerted antiviral properties against several viruses. In this study, anti-rotaviral efficacy of Glycyrrhiza uralensis extract (GUE) as an effective and cheaper remedy without side-effects was evaluated in colostrums-deprived piglets after induction of rotavirus diarrhea. Methods Colostrums-deprived piglets were inoculated with porcine rotavirus K85 (G5P[7]) strain. On the onset of diarrhea, piglets were treated with different concentration of GUE. To evaluate the antiviral efficacy of GUE, fecal consistency score, fecal virus shedding and histological changes of the small intestine, mRNA expression levels of inflammation-related cytokines (IL8, IL10, IFN-β, IFN-γ and TNF-α), signaling molecules (p38 and JNK), and transcription factor (NFκB) in the small intestine and spleen were determined. Results Among the dosages (100-400 mg/ml) administrated to animals, 400 mg/ml of GUE cured diarrhea, and markedly improved small intestinal lesion score and fecal virus shedding. mRNA expression levels of inflammation-related cytokines (IL8, IL10, IFN-β, IFN-γ and TNF-α), signaling molecules (p38 and JNK), and transcription factor (NFκB) in the small intestine and spleen were markedly increased in animals with RVA-induced diarrhea, but dose- dependently decreased in GUE treated animals after RVA-induced diarrhea. Conclusions GUE cures rotaviral enteritis by coordinating antiviral and anti-inflammatory effects. Therapy of this herbal medicine can be a viable medication for curing rotaviral enteritis in animals and humans. PMID:23244491
A living model for obesity and aging research: Caenorhabditis elegans.
Shen, Peiyi; Yue, Yiren; Park, Yeonhwa
2018-03-24
Caenorhabditis elegans (C. elegans) is a free-living nematode that has been extensively utilized as an animal model for research involving aging and neurodegenerative diseases, like Alzheimer's and Parkinson's, etc. Compared with traditional animal models, this small nematode possesses many benefits, such as small body size, short lifespan, completely sequenced genome, and more than 65% of the genes associated with human disease. All these characteristics make this organism an ideal living system for obesity and aging studies. This review gives a brief introduction of C. elegans as an animal model, highlights some advantages of research using this model and describes methods to evaluate the effect of treatments on obesity and aging of this organism.
Mueller, Ralf S; Olivry, Thierry
2017-08-30
The gold standard to diagnose adverse food reactions (AFRs) in the dog and cat is currently an elimination diet with subsequent provocation trials. However, those trials are inconvenient and client compliance can be low. Our objective was to systematically review the literature to evaluate in vivo and in vitro tests used to diagnose AFR in small animals. We searched three databases (CAB Abstracts, MEDLINE and Web of Science) for pertinent references on September 16, 2016. Among 71, 544 and 41 articles found in the CAB Abstract, MEDLINE and Web of Science databases, respectively, we selected 22 articles and abstracts from conference proceedings that reported data usable for evaluation of tests for AFR. Serum tests for food-specific IgE and IgG, intradermal testing with food antigens, lymphocyte proliferation tests, fecal food-specific IgE, patch, gastroscopic, and colonoscopic testing were evaluated. Testing for serum food-specific IgE and IgG showed low repeatability and, in dogs, a highly variable accuracy. In cats, the accuracy of testing for food-specific IgE was low. Lymphocyte proliferation tests were more frequently positive and more accurate in animals with AFR, but, as they are more difficult to perform, they remain currently a research tool. All other reported tests were only evaluated by individual studies with small numbers of animals. Negative patch test reactions have a very high negative predictability in dogs and could enable a choice of ingredients for the elimination diet in selected patients. Gastroscopic and colonoscopic testing as well as food-specific fecal IgE or food-specific serum IgG measurements appear less useful. Currently, the best diagnostic procedure to identify AFRs in small animals remains an elimination diet with subsequent provocation trials.
Monte Carlo-based evaluation of S-values in mouse models for positron-emitting radionuclides
NASA Astrophysics Data System (ADS)
Xie, Tianwu; Zaidi, Habib
2013-01-01
In addition to being a powerful clinical tool, Positron emission tomography (PET) is also used in small laboratory animal research to visualize and track certain molecular processes associated with diseases such as cancer, heart disease and neurological disorders in living small animal models of disease. However, dosimetric characteristics in small animal PET imaging are usually overlooked, though the radiation dose may not be negligible. In this work, we constructed 17 mouse models of different body mass and size based on the realistic four-dimensional MOBY mouse model. Particle (photons, electrons and positrons) transport using the Monte Carlo method was performed to calculate the absorbed fractions and S-values for eight positron-emitting radionuclides (C-11, N-13, O-15, F-18, Cu-64, Ga-68, Y-86 and I-124). Among these radionuclides, O-15 emits positrons with high energy and frequency and produces the highest self-absorbed S-values in each organ, while Y-86 emits γ-rays with high energy and frequency which results in the highest cross-absorbed S-values for non-neighbouring organs. Differences between S-values for self-irradiated organs were between 2% and 3%/g difference in body weight for most organs. For organs irradiating other organs outside the splanchnocoele (i.e. brain, testis and bladder), differences between S-values were lower than 1%/g. These appealing results can be used to assess variations in small animal dosimetry as a function of total-body mass. The generated database of S-values for various radionuclides can be used in the assessment of radiation dose to mice from different radiotracers in small animal PET experiments, thus offering quantitative figures for comparative dosimetry research in small animal models.
Evaluation of micro-GPS receivers for tracking small-bodied mammals
Shipley, Lisa A.; Forbey, Jennifer S.; Olsoy, Peter J.
2017-01-01
GPS telemetry markedly enhances the temporal and spatial resolution of animal location data, and recent advances in micro-GPS receivers permit their deployment on small mammals. One such technological advance, snapshot technology, allows for improved battery life by reducing the time to first fix via postponing recovery of satellite ephemeris (satellite location) data and processing of locations. However, no previous work has employed snapshot technology for small, terrestrial mammals. We evaluated performance of two types of micro-GPS (< 20 g) receivers (traditional and snapshot) on a small, semi-fossorial lagomorph, the pygmy rabbit (Brachylagus idahoensis), to understand how GPS errors might influence fine-scale assessments of space use and habitat selection. During stationary tests, microtopography (i.e., burrows) and satellite geometry had the largest influence on GPS fix success rate (FSR) and location error (LE). There was no difference between FSR while animals wore the GPS collars above ground (determined via light sensors) and FSR generated during stationary, above-ground trials, suggesting that animal behavior other than burrowing did not markedly influence micro-GPS errors. In our study, traditional micro-GPS receivers demonstrated similar FSR and LE to snapshot receivers, however, snapshot receivers operated inconsistently due to battery and software failures. In contrast, the initial traditional receivers deployed on animals experienced some breakages, but a modified collar design consistently functioned as expected. If such problems were resolved, snapshot technology could reduce the tradeoff between fix interval and battery life that occurs with traditional micro-GPS receivers. Our results suggest that micro-GPS receivers are capable of addressing questions about space use and resource selection by small mammals, but that additional techniques might be needed to identify use of habitat structures (e.g., burrows, tree cavities, rock crevices) that could affect micro-GPS performance and bias study results. PMID:28301495
Exposure to Animal Feces and Human Health: A Systematic Review and Proposed Research Priorities
2017-01-01
Humans can be exposed to pathogens from poorly managed animal feces, particularly in communities where animals live in close proximity to humans. This systematic review of peer-reviewed and gray literature examines the human health impacts of exposure to poorly managed animal feces transmitted via water, sanitation, and hygiene (WASH)-related pathways in low- and middle-income countries, where household livestock, small-scale animal operations, and free-roaming animals are common. We identify routes of contamination by animal feces, control measures to reduce human exposure, and propose research priorities for further inquiry. Exposure to animal feces has been associated with diarrhea, soil-transmitted helminth infection, trachoma, environmental enteric dysfunction, and growth faltering. Few studies have evaluated control measures, but interventions include reducing cohabitation with animals, provision of animal feces scoops, controlling animal movement, creating safe child spaces, improving veterinary care, and hygiene promotion. Future research should evaluate: behaviors related to points of contact with animal feces; animal fecal contamination of food; cultural behaviors of animal fecal management; acute and chronic health risks associated with exposure to animal feces; and factors influencing concentrations and shedding rates of pathogens originating from animal feces. PMID:28926696
NASA Astrophysics Data System (ADS)
Badea, C. T.; Samei, E.; Ghaghada, K.; Saunders, R.; Yuan, H.; Qi, Y.; Hedlund, L. W.; Mukundan, S.
2008-03-01
Imaging tumor angiogenesis in small animals is extremely challenging due to the size of the tumor vessels. Consequently, both dedicated small animal imaging systems and specialized intravascular contrast agents are required. The goal of this study was to investigate the use of a liposomal contrast agent for high-resolution micro-CT imaging of breast tumors in small animals. A liposomal blood pool agent encapsulating iodine with a concentration of 65.5 mg/ml was used with a Duke Center for In Vivo Microscopy (CIVM) prototype micro-computed tomography (micro-CT) system to image the R3230AC mammary carcinoma implanted in rats. The animals were injected with equivalent volume doses (0.02 ml/kg) of contrast agent. Micro-CT with the liposomal blood pool contrast agent ensured a signal difference between the blood and the muscle higher than 450 HU allowing the visualization of the tumors 3D vascular architecture in exquisite detail at 100-micron resolution. The micro-CT data correlated well with the histological examination of tumor tissue. We also studied the ability to detect vascular enhancement with limited angle based reconstruction, i.e. tomosynthesis. Tumor volumes and their regional vascular percentage were estimated. This imaging approach could be used to better understand tumor angiogenesis and be the basis for evaluating anti-angiogenic therapies.
Final Report 2007: DOE-FG02-87ER60561
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kilbourn, Michael R
2007-04-26
This project involved a multi-faceted approach to the improvement of techniques used in Positron Emission Tomography (PET), from radiochemistry to image processing and data analysis. New methods for radiochemical syntheses were examined, new radiochemicals prepared for evaluation and eventual use in human PET studies, and new pre-clinical methods examined for validation of biochemical parameters in animal studies. The value of small animal PET imaging in measuring small changes of in vivo biochemistry was examined and directly compared to traditional tissue sampling techniques. In human imaging studies, the ability to perform single experimental sessions utilizing two overlapping injections of radiopharmaceuticals wasmore » tested, and it was shown that valid biochemical measures for both radiotracers can be obtained through careful pharmacokinetic modeling of the PET emission data. Finally, improvements in reconstruction algorithms for PET data from small animal PET scanners was realized and these have been implemented in commercial releases. Together, the project represented an integrated effort to improve and extend all basic science aspects of PET imaging at both the animal and human level.« less
Irradiation Design for an Experimental Murine Model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ballesteros-Zebadua, P.; Moreno-Jimenez, S.; Suarez-Campos, J. E.
2010-12-07
In radiotherapy and stereotactic radiosurgery, small animal experimental models are frequently used, since there are still a lot of unsolved questions about the biological and biochemical effects of ionizing radiation. This work presents a method for small-animal brain radiotherapy compatible with a dedicated 6MV Linac. This rodent model is focused on the research of the inflammatory effects produced by ionizing radiation in the brain. In this work comparisons between Pencil Beam and Monte Carlo techniques, were used in order to evaluate accuracy of the calculated dose using a commercial planning system. Challenges in this murine model are discussed.
Badke, Yvonne M; Bates, Ronald O; Ernst, Catherine W; Fix, Justin; Steibel, Juan P
2014-04-16
Genomic selection has the potential to increase genetic progress. Genotype imputation of high-density single-nucleotide polymorphism (SNP) genotypes can improve the cost efficiency of genomic breeding value (GEBV) prediction for pig breeding. Consequently, the objectives of this work were to: (1) estimate accuracy of genomic evaluation and GEBV for three traits in a Yorkshire population and (2) quantify the loss of accuracy of genomic evaluation and GEBV when genotypes were imputed under two scenarios: a high-cost, high-accuracy scenario in which only selection candidates were imputed from a low-density platform and a low-cost, low-accuracy scenario in which all animals were imputed using a small reference panel of haplotypes. Phenotypes and genotypes obtained with the PorcineSNP60 BeadChip were available for 983 Yorkshire boars. Genotypes of selection candidates were masked and imputed using tagSNP in the GeneSeek Genomic Profiler (10K). Imputation was performed with BEAGLE using 128 or 1800 haplotypes as reference panels. GEBV were obtained through an animal-centric ridge regression model using de-regressed breeding values as response variables. Accuracy of genomic evaluation was estimated as the correlation between estimated breeding values and GEBV in a 10-fold cross validation design. Accuracy of genomic evaluation using observed genotypes was high for all traits (0.65-0.68). Using genotypes imputed from a large reference panel (accuracy: R(2) = 0.95) for genomic evaluation did not significantly decrease accuracy, whereas a scenario with genotypes imputed from a small reference panel (R(2) = 0.88) did show a significant decrease in accuracy. Genomic evaluation based on imputed genotypes in selection candidates can be implemented at a fraction of the cost of a genomic evaluation using observed genotypes and still yield virtually the same accuracy. On the other side, using a very small reference panel of haplotypes to impute training animals and candidates for selection results in lower accuracy of genomic evaluation.
Alligood, Christina A; Dorey, Nicole R; Mehrkam, Lindsay R; Leighty, Katherine A
2017-05-01
Environmental enrichment in zoos and aquariums is often evaluated at two overlapping levels: published research and day-to-day institutional record keeping. Several authors have discussed ongoing challenges with small sample sizes in between-groups zoological research and have cautioned against the inappropriate use of inferential statistics (Shepherdson, , International Zoo Yearbook, 38, 118-124; Shepherdson, Lewis, Carlstead, Bauman, & Perrin, Applied Animal Behaviour Science, 147, 298-277; Swaisgood, , Applied Animal Behaviour Science, 102, 139-162; Swaisgood & Shepherdson, , Zoo Biology, 24, 499-518). Multi-institutional studies are the typically-prescribed solution, but these are expensive and difficult to carry out. Kuhar ( Zoo Biology, 25, 339-352) provided a reminder that inferential statistics are only necessary when one wishes to draw general conclusions at the population level. Because welfare is assessed at the level of the individual animal, we argue that evaluations of enrichment efficacy are often instances in which inferential statistics may be neither necessary nor appropriate. In recent years, there have been calls for the application of behavior-analytic techniques to zoo animal behavior management, including environmental enrichment (e.g., Bloomsmith, Marr, & Maple, , Applied Animal Behaviour Science, 102, 205-222; Tarou & Bashaw, , Applied Animal Behaviour Science, 102, 189-204). Single-subject (also called single-case, or small-n) designs provide a means of designing evaluations of enrichment efficacy based on an individual's behavior. We discuss how these designs might apply to research and practice goals at zoos and aquariums, contrast them with standard practices in the field, and give examples of how each could be successfully applied in a zoo or aquarium setting. © 2017 Wiley Periodicals, Inc.
A study of video frame rate on the perception of moving imagery detail
NASA Technical Reports Server (NTRS)
Haines, Richard F.; Chuang, Sherry L.
1993-01-01
The rate at which each frame of color moving video imagery is displayed was varied in small steps to determine what is the minimal acceptable frame rate for life scientists viewing white rats within a small enclosure. Two, twenty five second-long scenes (slow and fast animal motions) were evaluated by nine NASA principal investigators and animal care technicians. The mean minimum acceptable frame rate across these subjects was 3.9 fps both for the slow and fast moving animal scenes. The highest single trial frame rate averaged across all subjects for the slow and the fast scene was 6.2 and 4.8, respectively. Further research is called for in which frame rate, image size, and color/gray scale depth are covaried during the same observation period.
Brodin, N. Patrik; Chen, Yong; Yaparpalvi, Ravindra; Guha, Chandan; Tomé, Wolfgang A.
2015-01-01
Shielded 137Cs irradiators are routinely used in pre-clinical radiation research to perform in vitro or in vivo investigations. Without appropriate dosimetry and irradiation protocols in place, there can be large uncertainty in the delivered dose of radiation between irradiated subjects that could lead to inaccurate and possibly misleading results. Here, a dosimetric evaluation of the JL Shepard Mark I-68A 137Cs irradiator and an irradiation technique for whole-body irradiation of small animals that allows one to limit the between subject variation in delivered dose to ±3% are provided. Mathematical simulation techniques and Gafchromic EBT film were used to describe the region within the irradiation cavity with homogeneous dose distribution (100% ±5%), the dosimetric impact of varying source-to-subject distance, and the variation in attenuation thickness due to turntable rotation. Furthermore, an irradiation protocol and dosimetry formalism that allows calculation of irradiation time for whole-body irradiation of small animals is proposed, that is designed to ensure a more consistent dose delivery between irradiated subjects. To compare this protocol with the conventional irradiation protocol suggested by the vendor, high-resolution film dosimetry measurements evaluating the dose difference between irradiation subjects and the dose distribution throughout subjects was performed, using phantoms resembling small animals. Based on these results, there can be considerable variation in the delivered dose of > ±5% using the conventional irradiation protocol for whole-body irradiation doses below 5 Gy. Using the proposed irradiation protocol this variability can be reduced to within ±3% and the dosimetry formalism allows for more accurate calculation of the irradiation time in relation to the intended prescription dose. PMID:26710162
Noninvasive imaging of experimental lung fibrosis.
Zhou, Yong; Chen, Huaping; Ambalavanan, Namasivayam; Liu, Gang; Antony, Veena B; Ding, Qiang; Nath, Hrudaya; Eary, Janet F; Thannickal, Victor J
2015-07-01
Small animal models of lung fibrosis are essential for unraveling the molecular mechanisms underlying human fibrotic lung diseases; additionally, they are useful for preclinical testing of candidate antifibrotic agents. The current end-point measures of experimental lung fibrosis involve labor-intensive histological and biochemical analyses. These measures fail to account for dynamic changes in the disease process in individual animals and are limited by the need for large numbers of animals for longitudinal studies. The emergence of noninvasive imaging technologies provides exciting opportunities to image lung fibrosis in live animals as often as needed and to longitudinally track the efficacy of novel antifibrotic compounds. Data obtained by noninvasive imaging provide complementary information to histological and biochemical measurements. In addition, the use of noninvasive imaging in animal studies reduces animal usage, thus satisfying animal welfare concerns. In this article, we review these new imaging modalities with the potential for evaluation of lung fibrosis in small animal models. Such techniques include micro-computed tomography (micro-CT), magnetic resonance imaging, positron emission tomography (PET), single photon emission computed tomography (SPECT), and multimodal imaging systems including PET/CT and SPECT/CT. It is anticipated that noninvasive imaging will be increasingly used in animal models of fibrosis to gain insights into disease pathogenesis and as preclinical tools to assess drug efficacy.
Chebroux, A; Leece, E A; Brearley, J C
2015-04-01
To evaluate animal comfort and ease of placement of a veterinary-specific intravenous catheter compared with a catheter manufactured for human use. Fifty-nine veterinary undergraduates were recruited to perform intravenous catheterisations with two brands of over-the-needle catheter [Smiths Medical Jelco® (human use) and Abbott Animal Health catheter® (veterinary use)] in 69 healthy cats (n = 28) and dogs (n = 41) requiring general anaesthesia. After a standardised pre-anaesthetic medication, each animal was randomly allocated to have one of the two brands of catheter placed. Each student was allowed a maximum of three attempts to achieve cephalic vein catheterisation. The student and a single experienced observer evaluated each attempt. Observations related to ease of placement and to the animal's reaction were recorded. Human use catheters were placed in 34 and veterinary use in 35 animals. There was no difference in weight, sex or sedation score between the two groups. The number of failed attempts was similar between the two groups. There was no difference between groups for the number of animals reacting to catheter insertion. The two types of catheters evaluated are equally suitable for intravenous catheterisation of sedated animals by veterinary undergraduate students. © 2015 British Small Animal Veterinary Association.
Development of a combined microSPECT/CT system for small animal imaging
NASA Astrophysics Data System (ADS)
Sun, Mingshan
Modern advances in the biomedical sciences have placed increased attention on small animals such as mice and rats as models of human biology and disease in biological research and pharmaceutical development. Their small size and fast breeding rate, their physiologic similarity to human, and, more importantly, the availability of sophisticated genetic manipulations, all have made mice and rats the laboratory mammals of choice in these experimental studies. However, the increased use of small animals in biomedical research also calls for new instruments that can measure the anatomic and metabolic information noninvasively with adequate spatial resolution and measurement sensitivity to facilitate these studies. This dissertation describes the engineering development of a combined single photon emission computed tomography (SPECT) and X-ray computed tomography (CT) system dedicated for small animals imaging. The system aims to obtain both the anatomic and metabolic images with submillimeter spatial resolution in a way that the data can be correlated to provide improved image quality and to offer more complete biological evaluation for biomedical studies involving small animals. The project requires development of complete microSPECT and microCT subsystems. Both subsystems are configured with a shared gantry and animal bed with integrated instrumentation for data acquisition and system control. The microCT employs a microfocus X-ray tube and a CCD-based detector for low noise, high resolution imaging. The microSPECT utilizes three semiconductor detectors coupled with pinhole collimators. A significant contribution of this dissertation project is the development of iterative algorithms with geometrical compensation that allows radionuclide images to be reconstructed at submillimeter spatial resolution, but with significantly higher detection efficiency than conventional methods. Both subsystems are capable of helical scans, offering lengthened field of view and improved axial resolution. System performance of both modalities is characterized with phantoms and animals. The microSPECT shows 0.6 mm resolution and 60 cps/MBq detection efficiency for imaging mice with 0.5 mm pinholes. The microCT achieves 120 mum spatial resolution on detector but with a relatively low detective quantum efficiency of 0.2 at the zero frequency. The combined system demonstrates a flexible platform for instrumentation development and a valuable tool for biomedical research. In summary, this dissertation describes the development of a combined SPECT/CT system for imaging the physiological function and anatomical structure in small animals.
Xie, Tianwu; Zaidi, Habib
2016-01-01
The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future.
Residues of carcinogenic animal drugs in food: difficulties in evaluation of human safety.
Somogyi, A
1979-01-01
The indisputable need to intensify animal production in order to provide an adequate food supply for the world population involves the use of substances that are highly potent pharmacologically and toxicologically. The history of regulatory action with regard to such additives is similar to that for other substances: first, no regulation; next, an over-reaction; and now decisions based on judicious evaluation of scientific facts. One factor that differentiates the chemicals used in animal production from other food additives is that both the parent compounds and their metabolites appear in edible products, posing problems both for the analytical detection and safety evaluation of such residues. It would be unrealistic to propose 'zero' tolerances for these additives, even if they are carcinogenic. The benefits gained from drugs that cure and prevent infections and parasitic diseases in food-producing animals, and the fact that analytical methods can now detect very small quantities make the presence of low levels of these substances in food unobjectionable.
Bigham-Sadegh, Amin; Oryan, Ahmad
2015-06-01
In vitro assays can be useful in determining biological mechanism and optimizing scaffold parameters, however translation of the in vitro results to clinics is generally hard. Animal experimentation is a better approximation than in vitro tests, and usage of animal models is often essential in extrapolating the experimental results and translating the information in a human clinical setting. In addition, usage of animal models to study fracture healing is useful to answer questions related to the most effective method to treat humans. There are several factors that should be considered when selecting an animal model. These include availability of the animal, cost, ease of handling and care, size of the animal, acceptability to society, resistance to surgery, infection and disease, biological properties analogous to humans, bone structure and composition, as well as bone modeling and remodeling characteristics. Animal experiments on bone healing have been conducted on small and large animals, including mice, rats, rabbits, dogs, pigs, goats and sheep. This review also describes the molecular events during various steps of fracture healing and explains different means of fracture healing evaluation including biomechanical, histopathological and radiological assessments.
Estimating trends in alligator populations from nightlight survey data
Fujisaki, Ikuko; Mazzotti, Frank J.; Dorazio, Robert M.; Rice, Kenneth G.; Cherkiss, Michael; Jeffery, Brian
2011-01-01
Nightlight surveys are commonly used to evaluate status and trends of crocodilian populations, but imperfect detection caused by survey- and location-specific factors makes it difficult to draw population inferences accurately from uncorrected data. We used a two-stage hierarchical model comprising population abundance and detection probability to examine recent abundance trends of American alligators (Alligator mississippiensis) in subareas of Everglades wetlands in Florida using nightlight survey data. During 2001–2008, there were declining trends in abundance of small and/or medium sized animals in a majority of subareas, whereas abundance of large sized animals had either demonstrated an increased or unclear trend. For small and large sized class animals, estimated detection probability declined as water depth increased. Detection probability of small animals was much lower than for larger size classes. The declining trend of smaller alligators may reflect a natural population response to the fluctuating environment of Everglades wetlands under modified hydrology. It may have negative implications for the future of alligator populations in this region, particularly if habitat conditions do not favor recruitment of offspring in the near term. Our study provides a foundation to improve inferences made from nightlight surveys of other crocodilian populations.
Estimating trends in alligator populations from nightlight survey data
Fujisaki, Ikuko; Mazzotti, F.J.; Dorazio, R.M.; Rice, K.G.; Cherkiss, M.; Jeffery, B.
2011-01-01
Nightlight surveys are commonly used to evaluate status and trends of crocodilian populations, but imperfect detection caused by survey- and location-specific factors makes it difficult to draw population inferences accurately from uncorrected data. We used a two-stage hierarchical model comprising population abundance and detection probability to examine recent abundance trends of American alligators (Alligator mississippiensis) in subareas of Everglades wetlands in Florida using nightlight survey data. During 2001-2008, there were declining trends in abundance of small and/or medium sized animals in a majority of subareas, whereas abundance of large sized animals had either demonstrated an increased or unclear trend. For small and large sized class animals, estimated detection probability declined as water depth increased. Detection probability of small animals was much lower than for larger size classes. The declining trend of smaller alligators may reflect a natural population response to the fluctuating environment of Everglades wetlands under modified hydrology. It may have negative implications for the future of alligator populations in this region, particularly if habitat conditions do not favor recruitment of offspring in the near term. Our study provides a foundation to improve inferences made from nightlight surveys of other crocodilian populations. ?? 2011 US Government.
Khiaosa-ard, R; Zebeli, Q
2013-04-01
The present study aimed at investigating the effects of essential oils and their bioactive compounds (EOBC) on rumen fermentation in vivo as well as animal performance and feed efficiency in different ruminant species, using a meta-analysis approach. Ruminant species were classified into 3 classes consisting of beef cattle, dairy cattle, and small ruminants. Two datasets (i.e., rumen fermentation and animal performance) were constructed, according to the available dependent variables within each animal class, from 28 publications (34 experiments) comprising a total of 97 dietary treatments. In addition, changes in rumen fermentation parameters relative to controls (i.e., no EOBC supplementation) of all animal classes were computed. Data were statistically analyzed within each animal class to evaluate the EOBC dose effect, taking into account variations of other variables across experiments (e.g., diet, feeding duration). The dose effect of EOBC on relative changes in fermentation parameters were analyzed across all animal classes. The primary results were that EOBC at doses <0.75 g/kg diet DM acted as a potential methane inhibitor in the rumen as a result of decreased acetate to propionate ratio. These responses were more pronounced in beef cattle (methane, P = 0.001; acetate to propionate ratio, P = 0.005) than in small ruminants (methane, P = 0.068; acetate to propionate ratio, P = 0.056) and in dairy cattle (P > 0.05), respectively. The analysis of relative changes in rumen fermentation variables suggests that EOBC affected protozoa numbers (P < 0.001) but only high doses (>0.20 g/kg DM) of EOBC had an inhibitory effect on this variable whereas lower doses promoted the number. For performance data, because numbers of observations in beef cattle and small ruminants were small, only those of dairy cattle (DMI, milk yield and milk composition, and feed efficiency) were analyzed. The results revealed no effect of EOBC dose on most parameters, except increased milk protein percentage (P< 0.001) and content (P = 0.006). It appears that EOBC supplementation can enhance rumen fermentation in such a way (i.e., decreased acetate to propionate ratio) that may favor beef production. High doses of EOBC do not necessarily modify rumen fermentation or improve animal performance and feed efficiency. Furthermore, additional attention should be paid to diet composition and supplementation period when evaluating the effects of EOBC in ruminants.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xie, Tianwu; Zaidi, Habib, E-mail: habib.zaidi@hcuge.ch; Geneva Neuroscience Center, Geneva University, Geneva CH-1205
The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and themore » development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future.« less
NASA Astrophysics Data System (ADS)
Wei, Qingyang; Wang, Shi; Ma, Tianyu; Wu, Jing; Liu, Hui; Xu, Tianpeng; Xia, Yan; Fan, Peng; Lyu, Zhenlei; Liu, Yaqiang
2015-06-01
PET, SPECT and CT imaging techniques are widely used in preclinical small animal imaging applications. In this paper, we present a compact small animal PET/SPECT/CT tri-modality system. A dual-functional, shared detector design is implemented which enables PET and SPECT imaging with a same LYSO ring detector. A multi-pinhole collimator is mounted on the system and inserted into the detector ring in SPECT imaging mode. A cone-beam CT consisting of a micro focus X-ray tube and a CMOS detector is implemented. The detailed design and the performance evaluations are reported in this paper. In PET imaging mode, the measured NEMA based spatial resolution is 2.12 mm (FWHM), and the sensitivity at the central field of view (CFOV) is 3.2%. The FOV size is 50 mm (∅)×100 mm (L). The SPECT has a spatial resolution of 1.32 mm (FWHM) and an average sensitivity of 0.031% at the center axial, and a 30 mm (∅)×90 mm (L) FOV. The CT spatial resolution is 8.32 lp/mm @10%MTF, and the contrast discrimination function value is 2.06% with 1.5 mm size cubic box object. In conclusion, a compact, tri-modality PET/SPECT/CT system was successfully built with low cost and high performance.
Evaluation of a cone beam computed tomography geometry for image guided small animal irradiation.
Yang, Yidong; Armour, Michael; Wang, Ken Kang-Hsin; Gandhi, Nishant; Iordachita, Iulian; Siewerdsen, Jeffrey; Wong, John
2015-07-07
The conventional imaging geometry for small animal cone beam computed tomography (CBCT) is that a detector panel rotates around the head-to-tail axis of an imaged animal ('tubular' geometry). Another unusual but possible imaging geometry is that the detector panel rotates around the anterior-to-posterior axis of the animal ('pancake' geometry). The small animal radiation research platform developed at Johns Hopkins University employs the pancake geometry where a prone-positioned animal is rotated horizontally between an x-ray source and detector panel. This study is to assess the CBCT image quality in the pancake geometry and investigate potential methods for improvement. We compared CBCT images acquired in the pancake geometry with those acquired in the tubular geometry when the phantom/animal was placed upright simulating the conventional CBCT geometry. Results showed signal-to-noise and contrast-to-noise ratios in the pancake geometry were reduced in comparison to the tubular geometry at the same dose level. But the overall spatial resolution within the transverse plane of the imaged cylinder/animal was better in the pancake geometry. A modest exposure increase to two folds in the pancake geometry can improve image quality to a level close to the tubular geometry. Image quality can also be improved by inclining the animal, which reduces streak artifacts caused by bony structures. The major factor resulting in the inferior image quality in the pancake geometry is the elevated beam attenuation along the long axis of the phantom/animal and consequently increased scatter-to-primary ratio in that orientation. Not withstanding, the image quality in the pancake-geometry CBCT is adequate to support image guided animal positioning, while providing unique advantages of non-coplanar and multiple mice irradiation. This study also provides useful knowledge about the image quality in the two very different imaging geometries, i.e. pancake and tubular geometry, respectively.
Evaluation of a Cone Beam Computed Tomography Geometry for Image Guided Small Animal Irradiation
Yang, Yidong; Armour, Michael; Wang, Ken Kang-Hsin; Gandhi, Nishant; Iordachita, Iulian; Siewerdsen, Jeffrey; Wong, John
2015-01-01
The conventional imaging geometry for small animal cone beam computed tomography (CBCT) is that a detector panel rotates around the head-to-tail axis of an imaged animal (“tubular” geometry). Another unusual but possible imaging geometry is that the detector panel rotates around the anterior-to-posterior axis of the animal (“pancake” geometry). The small animal radiation research platform (SARRP) developed at Johns Hopkins University employs the pancake geometry where a prone-positioned animal is rotated horizontally between an x-ray source and detector panel. This study is to assess the CBCT image quality in the pancake geometry and investigate potential methods for improvement. We compared CBCT images acquired in the pancake geometry with those acquired in the tubular geometry when the phantom/animal was placed upright simulating the conventional CBCT geometry. Results showed signal-to-noise and contrast-to-noise ratios in the pancake geometry were reduced in comparison to the tubular geometry at the same dose level. But the overall spatial resolution within the transverse plane of the imaged cylinder/animal was better in the pancake geometry. A modest exposure increase to two folds in the pancake geometry can improve image quality to a level close to the tubular geometry. Image quality can also be improved by inclining the animal, which reduces streak artifacts caused by bony structures. The major factor resulting in the inferior image quality in the pancake geometry is the elevated beam attenuation along the long axis of the phantom/animal and consequently increased scatter-to-primary ratio in that orientation. Notwithstanding, the image quality in the pancake-geometry CBCT is adequate to support image guided animal positioning, while providing unique advantages of non-coplanar and multiple mice irradiation. This study also provides useful knowledge about the image quality in the two very different imaging geometries, i.e., pancake and tubular geometry, respectively. PMID:26083659
Monitoring of small laboratory animal experiments by a designated web-based database.
Frenzel, T; Grohmann, C; Schumacher, U; Krüll, A
2015-10-01
Multiple-parametric small animal experiments require, by their very nature, a sufficient number of animals which may need to be large to obtain statistically significant results.(1) For this reason database-related systems are required to collect the experimental data as well as to support the later (re-) analysis of the information gained during the experiments. In particular, the monitoring of animal welfare is simplified by the inclusion of warning signals (for instance, loss in body weight >20%). Digital patient charts have been developed for human patients but are usually not able to fulfill the specific needs of animal experimentation. To address this problem a unique web-based monitoring system using standard MySQL, PHP, and nginx has been created. PHP was used to create the HTML-based user interface and outputs in a variety of proprietary file formats, namely portable document format (PDF) or spreadsheet files. This article demonstrates its fundamental features and the easy and secure access it offers to the data from any place using a web browser. This information will help other researchers create their own individual databases in a similar way. The use of QR-codes plays an important role for stress-free use of the database. We demonstrate a way to easily identify all animals and samples and data collected during the experiments. Specific ways to record animal irradiations and chemotherapy applications are shown. This new analysis tool allows the effective and detailed analysis of huge amounts of data collected through small animal experiments. It supports proper statistical evaluation of the data and provides excellent retrievable data storage. © The Author(s) 2015.
Dynamic studies of small animals with a four-color diffuse optical tomography imager
NASA Astrophysics Data System (ADS)
Schmitz, Christoph H.; Graber, Harry L.; Pei, Yaling; Farber, Mark; Stewart, Mark; Levina, Rita D.; Levin, Mikhail B.; Xu, Yong; Barbour, Randall L.
2005-09-01
We present newly developed instrumentation for full-tomographic four-wavelength, continuous wave, diffuse optical tomography (DOT) imaging on small animals. A small-animal imaging stage was constructed, from materials compatible with in-magnet studies, which offers stereotaxic fixation of the animal and precise, stable probe positioning. Instrument performance, based on calibration and phantom studies, demonstrates excellent long-term signal stability. DOT measurements of the functional rat brain response to electric paw stimulation are presented, and these demonstrate high data quality and excellent sensitivity to hemodynamic changes. A general linear model analysis on individual trials is used to localize and quantify the occurrence of functional behavior associated with the different hemoglobin state responses. Statistical evaluation of outcomes of individual trials is employed to identify significant regional response variations for different stimulation sites. Image results reveal a diffuse cortical response and a strong reaction of the thalamus, both indicative of activation of pain pathways by the stimulation. In addition, a weaker lateralized functional component is observed in the brain response, suggesting presence of motor activation. An important outcome of the experiment is that it shows that reactions to individual provocations can be monitored, without having to resort to signal averaging. Thus the described technology may be useful for studies of long-term trends in hemodynamic response, as would occur, for example, in behavioral studies involving freely moving animals.
Hematology of healthy Florida manatees (Trichechus manatus).
Harvey, John W; Harr, Kendal E; Murphy, David; Walsh, Michael T; Nolan, Elizabeth C; Bonde, Robert K; Pate, Melanie G; Deutsch, Charles J; Edwards, Holly H; Clapp, William L
2009-06-01
Hematologic analysis is an important tool in evaluating the general health status of free-ranging manatees and in the diagnosis and monitoring of rehabilitating animals. The purpose of this study was to evaluate diagnostically important hematologic analytes in healthy manatees (Trichechus manatus) and to assess variations with respect to location (free ranging vs captive), age class (small calves, large calves, subadults, and adults), and gender. Blood was collected from 55 free-ranging and 63 captive healthy manatees. Most analytes were measured using a CELL-DYN 3500R; automated reticulocytes were measured with an ADVIA 120. Standard manual methods were used for differential leukocyte counts, reticulocyte and Heinz body counts, and plasma protein and fibrinogen concentrations. Rouleaux, slight polychromasia, stomatocytosis, and low numbers of schistocytes and nucleated RBCs (NRBCs) were seen often in stained blood films. Manual reticulocyte counts were higher than automated reticulocyte counts. Heinz bodies were present in erythrocytes of most manatees. Compared with free-ranging manatees, captive animals had slightly lower MCV, MCH, and eosinophil counts and slightly higher heterophil and NRBC counts, and fibrinogen concentration. Total leukocyte, heterophil, and monocyte counts tended to be lower in adults than in younger animals. Small calves tended to have higher reticulocyte counts and NRBC counts than older animals. Hematologic findings were generally similar between captive and free-ranging manatees. Higher manual reticulocyte counts suggest the ADVIA detects only reticulocytes containing large amounts of RNA. Higher reticulocyte and NRBC counts in young calves probably reflect an increased rate of erythropoiesis compared with older animals.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-27
... industry 223 entitled ``Small Entity Compliance Guide--Declaring Color Additives in Animal Foods.'' This... of certified color additives on the labels of animal food including animal feeds and pet foods. DATES... SECG entitled ``Small Entity Compliance Guide--Declaring Color Additives in Animal Foods.'' This SECG...
Green, Michael V.; Ostrow, Harold G.; Seidel, Jurgen; Pomper, Martin G.
2013-01-01
Human and small-animal positron emission tomography (PET) scanners with cylindrical geometry and conventional detectors exhibit a progressive reduction in radial spatial resolution with increasing radial distance from the geometric axis of the scanner. This “depth-of-interaction” (DOI) effect is sufficiently deleterious that many laboratories have devised novel schemes to reduce the magnitude of this effect and thereby yield PET images of greater quantitative accuracy. Here we examine experimentally the effects of a particular DOI correction method (dual-scintillator phoswich detectors with pulse shape discrimination) implemented in a small-animal PET scanner by comparing the same phantom and same mouse images with and without DOI correction. The results suggest that even this relatively coarse, two-level estimate of radial gamma ray interaction position significantly reduces the DOI parallax error. This study also confirms two less appreciated advantages of DOI correction: a reduction in radial distortion and radial source displacement as a source is moved toward the edge of the field of view and a resolution improvement detectable in the central field of view likely owing to improved spatial sampling. PMID:21084028
Green, Michael V; Ostrow, Harold G; Seidel, Jurgen; Pomper, Martin G
2010-12-01
Human and small-animal positron emission tomography (PET) scanners with cylindrical geometry and conventional detectors exhibit a progressive reduction in radial spatial resolution with increasing radial distance from the geometric axis of the scanner. This "depth-of-interaction" (DOI) effect is sufficiently deleterious that many laboratories have devised novel schemes to reduce the magnitude of this effect and thereby yield PET images of greater quantitative accuracy. Here we examine experimentally the effects of a particular DOI correction method (dual-scintillator phoswich detectors with pulse shape discrimination) implemented in a small-animal PET scanner by comparing the same phantom and same mouse images with and without DOI correction. The results suggest that even this relatively coarse, two-level estimate of radial gamma ray interaction position significantly reduces the DOI parallax error. This study also confirms two less appreciated advantages of DOI correction: a reduction in radial distortion and radial source displacement as a source is moved toward the edge of the field of view and a resolution improvement detectable in the central field of view likely owing to improved spatial sampling.
IDENTIFICATION AND CHARACTERIZATION OF DISEASE USING PULMONARY FUNCTION TESTS
Abstract
Pulmonary function testing is used routinely in human medicine to objectively define functional deficits in individuals with respiratory disease. Despite the fact that respiratory disease is a common problem in veterinary medicine, evaluation of the small animal pa...
Preliminary study for small animal preclinical hadrontherapy facility
NASA Astrophysics Data System (ADS)
Russo, G.; Pisciotta, P.; Cirrone, G. A. P.; Romano, F.; Cammarata, F.; Marchese, V.; Forte, G. I.; Lamia, D.; Minafra, L.; Bravatá, V.; Acquaviva, R.; Gilardi, M. C.; Cuttone, G.
2017-02-01
Aim of this work is the study of the preliminary steps to perform a particle treatment of cancer cells inoculated in small animals and to realize a preclinical hadrontherapy facility. A well-defined dosimetric protocol was developed to explicate the steps needed in order to perform a precise proton irradiation in small animals and achieve a highly conformal dose into the target. A precise homemade positioning and holding system for small animals was designed and developed at INFN-LNS in Catania (Italy), where an accurate Monte Carlo simulation was developed, using Geant4 code to simulate the treatment in order to choose the best animal position and perform accurately all the necessary dosimetric evaluations. The Geant4 application can also be used to realize dosimetric studies and its peculiarity consists in the possibility to introduce the real target composition in the simulation using the DICOM micro-CT image. This application was fully validated comparing the results with the experimental measurements. The latter ones were performed at the CATANA (Centro di AdroTerapia e Applicazioni Nucleari Avanzate) facility at INFN-LNS by irradiating both PMMA and water solid phantom. Dosimetric measurements were performed using previously calibrated EBT3 Gafchromic films as a detector and the results were compared with the Geant4 simulation ones. In particular, two different types of dosimetric studies were performed: the first one involved irradiation of a phantom made up of water solid slabs where a layer of EBT3 was alternated with two different slabs in a sandwich configuration, in order to validate the dosimetric distribution. The second one involved irradiation of a PMMA phantom made up of a half hemisphere and some PMMA slabs in order to simulate a subcutaneous tumour configuration, normally used in preclinical studies. In order to evaluate the accordance between experimental and simulation results, two different statistical tests were made: Kolmogorov test and gamma index test. This work represents the first step towards the realization of a preclinical hadrontherapy facility at INFN-LNS in Catania for the future in vivo studies.
Rey, Beatriz; Rodriguez-Pujadas, Aina; Breton-Lopez, Juani; Barros-Loscertales, Alfonso; Baños, Rosa M; Botella, Cristina; Alcañiz, Mariano; Avila, Cesar
2014-01-01
Background To date, still images or videos of real animals have been used in functional magnetic resonance imaging protocols to evaluate the brain activations associated with small animals’ phobia. Objective The objective of our study was to evaluate the brain activations associated with small animals’ phobia through the use of virtual environments. This context will have the added benefit of allowing the subject to move and interact with the environment, giving the subject the illusion of being there. Methods We have analyzed the brain activation in a group of phobic people while they navigated in a virtual environment that included the small animals that were the object of their phobia. Results We have found brain activation mainly in the left occipital inferior lobe (P<.05 corrected, cluster size=36), related to the enhanced visual attention to the phobic stimuli; and in the superior frontal gyrus (P<.005 uncorrected, cluster size=13), which is an area that has been previously related to the feeling of self-awareness. Conclusions In our opinion, these results demonstrate that virtual stimulus can enhance brain activations consistent with previous studies with still images, but in an environment closer to the real situation the subject would face in their daily lives. PMID:25654753
NASA Astrophysics Data System (ADS)
Jian, Yifan; Xu, Jing; Zawadzki, Robert J.; Sarunic, Marinko V.
2013-03-01
Small animal models of human retinal diseases are a critical component of vision research. In this report, we present an ultrahigh-resolution ultrahigh-speed adaptive optics optical coherence tomography (AO-OCT) system for small animal retinal imaging (mouse, fish, etc.). We adapted our imaging system to different types of small animals in accordance with the optical properties of their eyes. Results of AO-OCT images of small animal retinas acquired with AO correction are presented. Cellular structures including nerve fiber bundles, capillary networks and detailed double-cone photoreceptors are visualized.
GATE simulation of a new design of pinhole SPECT system for small animal brain imaging
NASA Astrophysics Data System (ADS)
Uzun Ozsahin, D.; Bläckberg, L.; El Fakhri, G.; Sabet, H.
2017-01-01
Small animal SPECT imaging has gained an increased interest over the past decade since it is an excellent tool for developing new drugs and tracers. Therefore, there is a huge effort on the development of cost-effective SPECT detectors with high capabilities. The aim of this study is to simulate the performance characteristics of new designs for a cost effective, stationary SPECT system dedicated to small animal imaging with a focus on mice brain. The conceptual design of this SPECT system platform, Stationary Small Animal SSA-SPECT, is to use many pixelated CsI:TI detector modules with 0.4 mm × 0.4 mm pixels in order to achieve excellent intrinsic detector resolution where each module is backed by a single pinhole collimator with 0.3 mm hole diameter. In this work, we present the simulation results of four variations of the SSA-SPECT platform where the number of detector modules and FOV size is varied while keeping the detector size and collimator hole size constant. Using the NEMA NU-4 protocol, we performed spatial resolution, sensitivity, image quality simulations followed by a Derenzo-like phantom evaluation. The results suggest that all four SSA-SPECT systems can provide better than 0.063% system sensitivity and < 1.5 mm FWHM spatial resolution without resolution recovery or other correction techniques. Specifically, SSA-SPECT-1 showed a system sensitivity of 0.09% in combination with 1.1 mm FWHM spatial resolution.
Stephens, Andrew N; Pereira-Fantini, Prue M; Wilson, Guineva; Taylor, Russell G; Rainczuk, Adam; Meehan, Katie L; Sourial, Magdy; Fuller, Peter J; Stanton, Peter G; Robertson, David M; Bines, Julie E
2010-03-05
Intestinal adaptation in response to the loss of the small intestine is essential to restore enteral autonomy in patients who have undergone massive small bowel resection (MSBR). In a proportion of patients, intestinal function is not restored, resulting in chronic intestinal failure (IF). Early referral of such patients for transplant provides the best prognosis; however, the molecular mechanisms underlying intestinal adaptation remain elusive and there is currently no convenient marker to predict whether patients will develop IF. We have investigated the adaptation response in a well-characterized porcine model of intestinal adaptation. 2D DIGE analysis of ileal epithelium from piglets recovering from massive small bowel resection (MSBR) identified over 60 proteins that changed specifically in MSBR animals relative to nonoperational or sham-operated controls. Three fatty acid binding proteins (L-FABP, FABP-6, and I-FABP) showed changes in MSBR animals. The expression changes and localization of each FABP were validated by immunoblotting and immunohistochemical analysis. FABP expression changes in MSBR animals occurred concurrently with altered triglyceride and bile acid metabolism as well as weight gain. The observed FABP expression changes in the ileal epithelium occur as part of the intestinal adaptation response and could provide a clinically useful marker to evaluate adaptation following MSBR.
2016-01-01
The standard approach in accounting for hierarchical differentiation in biology and the social sciences considers a hierarchy as a static distribution of individuals possessing differing amounts of some valued commodity, assumes that the hierarchy is generated by micro-level processes involving individuals, and attempts to reverse engineer the processes that produced the hierarchy. However, sufficient experimental and analytical results are available to evaluate this standard approach in the case of animal dominance hierarchies (pecking orders). Our evaluation using evidence from hierarchy formation in small groups of both hens and cichlid fish reveals significant deficiencies in the three tenets of the standard approach in accounting for the organization of dominance hierarchies. In consequence, we suggest that a new approach is needed to explain the organization of pecking orders and, very possibly, by implication, for other kinds of social hierarchies. We develop an example of such an approach that considers dominance hierarchies to be dynamic networks, uses dynamic sequences of interaction (dynamic network motifs) to explain the organization of dominance hierarchies, and derives these dynamic sequences directly from observation of hierarchy formation. We test this dynamical explanation using computer simulation and find a good fit with actual dynamics of hierarchy formation in small groups of hens. We hypothesize that the same dynamic sequences are used in small groups of many other animal species forming pecking orders, and we discuss the data required to evaluate our hypothesis. Finally, we briefly consider how our dynamic approach may be generalized to other kinds of social hierarchies using the example of the distribution of empty gastropod (snail) shells occupied in populations of hermit crabs. PMID:27410230
Samani, Mohsen Mosayebi; Mahnam, Amin; Hosseini, Nasrin
2014-04-01
Portable wireless neuro-stimulators have been developed to facilitate long-term cognitive and behavioral studies on the central nervous system in freely moving animals. These stimulators can provide precisely controllable input(s) to the nervous system, without distracting the animal attention with cables connected to its body. In this study, a low power backpack neuro-stimulator was developed for animal brain researches that can provides arbitrary stimulus waveforms for the stimulation, while it is small and light weight to be used for small animals including rats. The system consists of a controller that uses an RF link to program and activate a small and light microprocessor-based stimulator. A Howland current source was implemented to produce precise current controlled arbitrary waveform stimulations. The system was optimized for ultra-low power consumption and small size. The stimulator was first tested for its electrical specifications. Then its performance was evaluated in a rat experiment when electrical stimulation of medial longitudinal fasciculus induced circling behavior. The stimulator is capable of delivering programmed stimulations up to ± 2 mA with adjusting steps of 1 μA, accuracy of 0.7% and compliance of 6 V. The stimulator is 15 mm × 20 mm × 40 mm in size, weights 13.5 g without battery and consumes a total power of only 5.l mW. In the experiment, the rat could easily carry the stimulator and demonstrated the circling behavior for 0.1 ms current pulses of above 400 μA. The developed system has a competitive size and weight, whereas providing a wide range of operation and the flexibility of generating arbitrary stimulation patterns ideal for long-term experiments in the field of cognitive and neuroscience research.
Modeling in vivo fluorescence of small animals using TracePro software
NASA Astrophysics Data System (ADS)
Leavesley, Silas; Rajwa, Bartek; Freniere, Edward R.; Smith, Linda; Hassler, Richard; Robinson, J. Paul
2007-02-01
The theoretical modeling of fluorescence excitation, emission, and propagation within living tissue has been a limiting factor in the development and calibration of in vivo small animal fluorescence imagers. To date, no definitive calibration standard, or phantom, has been developed for use with small animal fluorescence imagers. Our work in the theoretical modeling of fluorescence in small animals using solid modeling software is useful in optimizing the design of small animal imaging systems, and in predicting their response to a theoretical model. In this respect, it is also valuable in the design of a fluorescence phantom for use in in vivo small animal imaging. The use of phantoms is a critical step in the testing and calibration of most diagnostic medical imaging systems. Despite this, a realistic, reproducible, and informative phantom has yet to be produced for use in small animal fluorescence imaging. By modeling the theoretical response of various types of phantoms, it is possible to determine which parameters are necessary for accurately modeling fluorescence within inhomogenous scattering media such as tissue. Here, we present the model that has been developed, the challenges and limitations associated with developing such a model, and the applicability of this model to experimental results obtained in a commercial small animal fluorescence imager.
Evaluating thermoregulation in reptiles: the fallacy of the inappropriately applied method.
Seebacher, Frank; Shine, Richard
2004-01-01
Given the importance of heat in most biological processes, studies on thermoregulation have played a major role in understanding the ecology of ectothermic vertebrates. It is, however, difficult to assess whether body temperature is actually regulated, and several techniques have been developed that allow an objective assessment of thermoregulation. Almost all recent studies on reptiles follow a single methodology that, when used correctly, facilitates comparisons between species, climates, and so on. However, the use of operative temperatures in this methodology assumes zero heat capacity of the study animals and is, therefore, appropriate for small animals only. Operative temperatures represent potentially available body temperatures accurately for small animals but can substantially overestimate the ranges of body temperature available to larger animals whose slower rates of heating and cooling mean that they cannot reach equilibrium if they encounter operative temperatures that change rapidly through either space or time. This error may lead to serious misinterpretations of field data. We derive correction factors specific for body mass and rate of movement that can be used to estimate body temperature null distributions of larger reptiles, thereby overcoming this methodological problem.
Scatter characterization and correction for simultaneous multiple small-animal PET imaging.
Prasad, Rameshwar; Zaidi, Habib
2014-04-01
The rapid growth and usage of small-animal positron emission tomography (PET) in molecular imaging research has led to increased demand on PET scanner's time. One potential solution to increase throughput is to scan multiple rodents simultaneously. However, this is achieved at the expense of deterioration of image quality and loss of quantitative accuracy owing to enhanced effects of photon attenuation and Compton scattering. The purpose of this work is, first, to characterize the magnitude and spatial distribution of the scatter component in small-animal PET imaging when scanning single and multiple rodents simultaneously and, second, to assess the relevance and evaluate the performance of scatter correction under similar conditions. The LabPET™-8 scanner was modelled as realistically as possible using Geant4 Application for Tomographic Emission Monte Carlo simulation platform. Monte Carlo simulations allow the separation of unscattered and scattered coincidences and as such enable detailed assessment of the scatter component and its origin. Simple shape-based and more realistic voxel-based phantoms were used to simulate single and multiple PET imaging studies. The modelled scatter component using the single-scatter simulation technique was compared to Monte Carlo simulation results. PET images were also corrected for attenuation and the combined effect of attenuation and scatter on single and multiple small-animal PET imaging evaluated in terms of image quality and quantitative accuracy. A good agreement was observed between calculated and Monte Carlo simulated scatter profiles for single- and multiple-subject imaging. In the LabPET™-8 scanner, the detector covering material (kovar) contributed the maximum amount of scatter events while the scatter contribution due to lead shielding is negligible. The out-of field-of-view (FOV) scatter fraction (SF) is 1.70, 0.76, and 0.11% for lower energy thresholds of 250, 350, and 400 keV, respectively. The increase in SF ranged between 25 and 64% when imaging multiple subjects (three to five) of different size simultaneously in comparison to imaging a single subject. The spill-over ratio (SOR) increases with increasing the number of subjects in the FOV. Scatter correction improved the SOR for both water and air cold compartments of single and multiple imaging studies. The recovery coefficients for different body parts of the mouse whole-body and rat whole-body anatomical models were improved for multiple imaging studies following scatter correction. The magnitude and spatial distribution of the scatter component in small-animal PET imaging of single and multiple subjects simultaneously were characterized, and its impact was evaluated in different situations. Scatter correction improves PET image quality and quantitative accuracy for single rat and simultaneous multiple mice and rat imaging studies, whereas its impact is insignificant in single mouse imaging.
PET performance evaluation of MADPET4: a small animal PET insert for a 7 T MRI scanner.
Omidvari, Negar; Cabello, Jorge; Topping, Geoffrey; Schneider, Florian R; Paul, Stephan; Schwaiger, Markus; Ziegler, Sibylle I
2017-11-01
MADPET4 is the first small animal PET insert with two layers of individually read out crystals in combination with silicon photomultiplier technology. It has a novel detector arrangement, in which all crystals face the center of field of view transaxially. In this work, the PET performance of MADPET4 was evaluated and compared to other preclinical PET scanners using the NEMA NU 4 measurements, followed by imaging a mouse-size hot-rod resolution phantom and two in vivo simultaneous PET/MRI scans in a 7 T MRI scanner. The insert had a peak sensitivity of 0.49%, using an energy threshold of 350 keV. A uniform transaxial resolution was obtained up to 15 mm radial offset from the axial center, using filtered back-projection with single-slice rebinning. The measured average radial and tangential resolutions (FWHM) were 1.38 mm and 1.39 mm, respectively. The 1.2 mm rods were separable in the hot-rod phantom using an iterative image reconstruction algorithm. The scatter fraction was 7.3% and peak noise equivalent count rate was 15.5 kcps at 65.1 MBq of activity. The FDG uptake in a mouse heart and brain were visible in the two in vivo simultaneous PET/MRI scans without applying image corrections. In conclusion, the insert demonstrated a good overall performance and can be used for small animal multi-modal research applications.
PET performance evaluation of MADPET4: a small animal PET insert for a 7 T MRI scanner
NASA Astrophysics Data System (ADS)
Omidvari, Negar; Cabello, Jorge; Topping, Geoffrey; Schneider, Florian R.; Paul, Stephan; Schwaiger, Markus; Ziegler, Sibylle I.
2017-11-01
MADPET4 is the first small animal PET insert with two layers of individually read out crystals in combination with silicon photomultiplier technology. It has a novel detector arrangement, in which all crystals face the center of field of view transaxially. In this work, the PET performance of MADPET4 was evaluated and compared to other preclinical PET scanners using the NEMA NU 4 measurements, followed by imaging a mouse-size hot-rod resolution phantom and two in vivo simultaneous PET/MRI scans in a 7 T MRI scanner. The insert had a peak sensitivity of 0.49%, using an energy threshold of 350 keV. A uniform transaxial resolution was obtained up to 15 mm radial offset from the axial center, using filtered back-projection with single-slice rebinning. The measured average radial and tangential resolutions (FWHM) were 1.38 mm and 1.39 mm, respectively. The 1.2 mm rods were separable in the hot-rod phantom using an iterative image reconstruction algorithm. The scatter fraction was 7.3% and peak noise equivalent count rate was 15.5 kcps at 65.1 MBq of activity. The FDG uptake in a mouse heart and brain were visible in the two in vivo simultaneous PET/MRI scans without applying image corrections. In conclusion, the insert demonstrated a good overall performance and can be used for small animal multi-modal research applications.
Hematology of healthy Florida manatees (Trichechus manatus)
Harvey, J.W.; Harr, K.E.; Murphy, D.; Walsh, M.T.; Nolan, E.C.; Bonde, R.K.; Pate, M.G.; Deutsch, C.J.; Edwards, H.H.; Clapp, W.L.
2009-01-01
Background: Hematologic analysis is an important tool in evaluating the general health status of free-ranging manatees and in the diagnosis and monitoring of rehabilitating animals. Objectives: The purpose of this study was to evaluate diagnostically important hematologic analytes in healthy manatees (Trichechus manatus) and to assess variations with respect to location (free ranging vs captive), age class (small calves, large calves, subadults, and adults), and gender. Methods: Blood was collected from 55 free-ranging and 63 captive healthy manatees. Most analytes were measured using a CELL-DYN 3500R; automated reticulocytes were measured with an ADVIA 120. Standard manual methods were used for differential leukocyte counts, reticulocyte and Heinz body counts, and plasma protein and fibrinogen concentrations. Results: Rouleaux, slight polychromasia, stomatocytosis, and low numbers of schistocytes and nucleated RBCs (NRBCs) were seen often in stained blood films. Manual reticulocyte counts were higher than automated reticulocyte counts. Heinz bodies were present in erythrocytes of most manatees. Compared with free-ranging manatees, captive animals had slightly lower MCV, MCH, and eosinophil counts and slightly higher heterophil and NRBC counts, and fibrinogen concentration. Total leukocyte, heterophil, and monocyte counts tended to be lower in adults than in younger animals. Small calves tended to have higher reticulocyte counts and NRBC counts than older animals. Conclusions: Hematologic findings were generally similar between captive and free-ranging manatees. Higher manual reticulocyte counts suggest the ADVIA detects only reticulocytes containing large amounts of RNA. Higher reticulocyte and NRBC counts in young calves probably reflect an increased rate of erythropoiesis compared with older animals. ?? 2009 American Society for Veterinary Clinical Pathology.
NASA Astrophysics Data System (ADS)
Trojanova, E.; Jakubek, J.; Turecek, D.; Sykora, V.; Francova, P.; Kolarova, V.; Sefc, L.
2018-01-01
The imaging method of SPECT (Single Photon Emission Computed Tomography) is used in nuclear medicine for diagnostics of various diseases or organs malfunctions. The distribution of medically injected, inhaled, or ingested radionuclides (radiotracers) in the patient body is imaged using gamma-ray sensitive camera with suitable imaging collimator. The 3D image is then calculated by combining many images taken from different observation angles. Most of SPECT systems use scintillator based cameras. These cameras do not provide good energy resolution and do not allow efficient suppression of unwanted signals such as those caused by Compton scattering. The main goal of this work is evaluation of Timepix3 detector properties for SPECT method for functional imaging of small animals during preclinical studies. Advantageous Timepix3 properties such as energy and spatial resolution are exploited for significant image quality improvement. Preliminary measurements were performed on specially prepared plastic phantom with cavities filled by radioisotopes and then repeated with in vivo mouse sample.
Ethical principles for novel therapies in veterinary practice.
Yeates, J W
2016-02-01
To present insights to aid decision-making about novel veterinary treatments from regulations concerning animal experimentation and human clinical medical trials. EU Directive 2010/63/EU on the protection of animals used for scientific purposes and EU Regulation 536/2014 on clinical trials on medicinal products for human use were analysed, evaluated and "translated" into relevant principles for veterinary surgeons. A number of principles are relevant, relating to treatment expectations, thresholds and objectives; client consent; minimising harms; personnel; review committees; assessment and publication. These principles should assist veterinary surgeons to make good ethical decisions about novel treatments. © 2015 British Small Animal Veterinary Association.
NASA Technical Reports Server (NTRS)
Kramer, George C.; Wade, Charles E.; Dubick, Michael A.; Atkins, James L.
2004-01-01
Introduction: Logistic constraints on combat casualty care preclude traditional resuscitation strategies which can require volumes and weights 3 fold or greater than hemorrhaged volume. We present a review of quantitative analyses of clinical and animal data on small volume strategies using 1) hypertonic-hyperosmotic solutions (HHS); 2) hemoglobin based oxygen carriers (HBOCs) and 3) closed-loop infusion regimens.Methods and Results: Literature searches and recent queries to industry and academic researchers have allowed us to evaluate the record of 81 human HHS studies (12 trauma trials), 19 human HBOCs studies (3trauma trials) and two clinical studies of closed-loop resuscitation.There are several hundreds animal studies and at least 82 clinical trials and reports evaluating small volume7.2%-7.5% hypertonic saline (HS) most often combined with colloids, e.g., dextran (HSD) or hetastarch(HSS). HSD and HSS data has been published for 1,108 and 392 patients, respectively. Human studies have documented volume sparing and hemodynamic improvements. Meta-analyses suggest improved survival for hypotensive trauma patients treated with HSD with significant reductions in mortality found for patients with blood pressure < 70 mmHg, head trauma, and penetrating injury requiring surgery. HSD and HSS have received regulatory approval in 14 and 3 countries, respectively, with 81,000+ units sold. The primary reported use was head injury and trauma resuscitation. Complications and reported adverse events are surprisingly rare and not significantly different from other solutions.HBOCs are potent volume expanders in addition to oxygen carriers with volume expansion greater than standard colloids. Several investigators have evaluated small volume hyperoncotic HBOCs or HS-HBOC formulations for hypotensive and normotensive resuscitation in animals. A consistent finding in resuscitation with HBOCs is depressed cardiac output. There is some evidence that HBOCs more efficiently unload oxygen from plasma hemoglobin as well as facilitate RBC unloading. We analyzed one volunteer study, 15 intraoperative trials, and 3 trauma studies using HBOCs. Perioperative studies generally suggest ability to deliver oxygen, but one trauma trial using HBOCs (HemAssist) for treatment of trauma resulted in a dramatic increase in mortality, while an intraoperative trauma study using Polyheme demonstrated reductions in blood use and lower mortality compared to historic controls of patients refusing blood. Transfusion reductions with HBOC use have been modest. Two HBOCs (Hemopure and Polyheme) are now in new or planned large-scale multicenter prehospital trials of trauma treatment. A new implementation of small volume resuscitation is closed-loop resuscitation (CLR), which employs microprocessors to titrate just enough fluid to reach a physiologic target . Animal studies suggest less risk of rebleeding in uncontrolled hemorrhage and a reduction in fluid needs with CLR. The first clinical application of CLR was treatment of burn shock and the US Army. Conclusions: Independently sponsored civilian trauma trials and clinical evaluations in operational combat conditions of different small volume strategies are warranted.
Going wild: what a global small-animal tracking system could do for experimental biologists.
Wikelski, Martin; Kays, Roland W; Kasdin, N Jeremy; Thorup, Kasper; Smith, James A; Swenson, George W
2007-01-01
Tracking animals over large temporal and spatial scales has revealed invaluable and spectacular biological information, particularly when the paths and fates of individuals can be monitored on a global scale. However, only large animals (greater than approximately 300 g) currently can be followed globally because of power and size constraints on the tracking devices. And yet the vast majority of animals is small. Tracking small animals is important because they are often part of evolutionary and ecological experiments, they provide important ecosystem services and they are of conservation concern or pose harm to human health. Here, we propose a small-animal satellite tracking system that would enable the global monitoring of animals down to the size of the smallest birds, mammals (bats), marine life and eventually large insects. To create the scientific framework necessary for such a global project, we formed the ICARUS initiative (www.IcarusInitiative.org), the International Cooperation for Animal Research Using Space. ICARUS also highlights how small-animal tracking could address some of the ;Grand Challenges in Environmental Sciences' identified by the US National Academy of Sciences, such as the spread of infectious diseases or the relationship between biological diversity and ecosystem functioning. Small-animal tracking would allow the quantitative assessment of dispersal and migration in natural populations and thus help solve enigmas regarding population dynamics, extinctions and invasions. Experimental biologists may find a global small-animal tracking system helpful in testing, validating and expanding laboratory-derived discoveries in wild, natural populations. We suggest that the relatively modest investment into a global small-animal tracking system will pay off by providing unprecedented insights into both basic and applied nature. Tracking small animals over large spatial and temporal scales could prove to be one of the most powerful techniques of the early 21st century, offering potential solutions to a wide range of biological and societal questions that date back two millennia to the Greek philosopher Aristotle's enigma about songbird migration. Several of the more recent Grand Challenges in Environmental Sciences, such as the regulation and functional consequences of biological diversity or the surveillance of the population ecology of zoonotic hosts, pathogens or vectors, could also be addressed by a global small-animal tracking system. Our discussion is intended to contribute to an emerging groundswell of scientific support to make such a new technological system happen.
GMOs in animal agriculture: time to consider both costs and benefits in regulatory evaluations.
Van Eenennaam, Alison L
2013-09-25
In 2012, genetically engineered (GE) crops were grown by 17.3 million farmers on over 170 million hectares. Over 70% of harvested GE biomass is fed to food producing animals, making them the major consumers of GE crops for the past 15 plus years. Prior to commercialization, GE crops go through an extensive regulatory evaluation. Over one hundred regulatory submissions have shown compositional equivalence, and comparable levels of safety, between GE crops and their conventional counterparts. One component of regulatory compliance is whole GE food/feed animal feeding studies. Both regulatory studies and independent peer-reviewed studies have shown that GE crops can be safely used in animal feed, and rDNA fragments have never been detected in products (e.g. milk, meat, eggs) derived from animals that consumed GE feed. Despite the fact that the scientific weight of evidence from these hundreds of studies have not revealed unique risks associated with GE feed, some groups are calling for more animal feeding studies, including long-term rodent studies and studies in target livestock species for the approval of GE crops. It is an opportune time to review the results of such studies as have been done to date to evaluate the value of the additional information obtained. Requiring long-term and target animal feeding studies would sharply increase regulatory compliance costs and prolong the regulatory process associated with the commercialization of GE crops. Such costs may impede the development of feed crops with enhanced nutritional characteristics and durability, particularly in the local varieties in small and poor developing countries. More generally it is time for regulatory evaluations to more explicitly consider both the reasonable and unique risks and benefits associated with the use of both GE plants and animals in agricultural systems, and weigh them against those associated with existing systems, and those of regulatory inaction. This would represent a shift away from a GE evaluation process that currently focuses only on risk assessment and identifying ever diminishing marginal hazards, to a regulatory approach that more objectively evaluates and communicates the likely impact of approving a new GE plant or animal on agricultural production systems.
GMOs in animal agriculture: time to consider both costs and benefits in regulatory evaluations
2013-01-01
In 2012, genetically engineered (GE) crops were grown by 17.3 million farmers on over 170 million hectares. Over 70% of harvested GE biomass is fed to food producing animals, making them the major consumers of GE crops for the past 15 plus years. Prior to commercialization, GE crops go through an extensive regulatory evaluation. Over one hundred regulatory submissions have shown compositional equivalence, and comparable levels of safety, between GE crops and their conventional counterparts. One component of regulatory compliance is whole GE food/feed animal feeding studies. Both regulatory studies and independent peer-reviewed studies have shown that GE crops can be safely used in animal feed, and rDNA fragments have never been detected in products (e.g. milk, meat, eggs) derived from animals that consumed GE feed. Despite the fact that the scientific weight of evidence from these hundreds of studies have not revealed unique risks associated with GE feed, some groups are calling for more animal feeding studies, including long-term rodent studies and studies in target livestock species for the approval of GE crops. It is an opportune time to review the results of such studies as have been done to date to evaluate the value of the additional information obtained. Requiring long-term and target animal feeding studies would sharply increase regulatory compliance costs and prolong the regulatory process associated with the commercialization of GE crops. Such costs may impede the development of feed crops with enhanced nutritional characteristics and durability, particularly in the local varieties in small and poor developing countries. More generally it is time for regulatory evaluations to more explicitly consider both the reasonable and unique risks and benefits associated with the use of both GE plants and animals in agricultural systems, and weigh them against those associated with existing systems, and those of regulatory inaction. This would represent a shift away from a GE evaluation process that currently focuses only on risk assessment and identifying ever diminishing marginal hazards, to a regulatory approach that more objectively evaluates and communicates the likely impact of approving a new GE plant or animal on agricultural production systems. PMID:24066781
NASA Astrophysics Data System (ADS)
Desbree, A.; Pain, F.; Gurden, H.; Pinot, L.; Grenier, D.; Zimmer, L.; Mastrippolito, R.; Laniece, P.
2005-10-01
Elucidating complex physiological mechanisms in small animal in vivo requires the development of new investigatory techniques including imaging with multiple modalities. Combining exploratory techniques has the tremendous advantage to record simultaneously complementary parameters on the same animal. In this field, an exciting challenge remains in the combination of nuclear magnetic resonance (NMR) and positron emission tomography (PET) since small animals studies are limited by strict technical constraints in vivo. Coupling NMR with a radiosensitive /spl beta/-MicroProbe offers therefore an interesting technical alternative. To assess the feasibility of this new dual-modality system, we designed theoretical and experimental approaches to test the ability of the /spl beta/-Microprobe to quantify radioactivity concentration in an intense magnetic field. In an initial step, simulations were carried out using Geant4. First, we evaluated the influence of a magnetic field on the probe detection volume. Then, the detection sensitivity and energy response of the probe were quantified. In a second step, experiments were run within a 7-T magnet to confirm our simulations results. We showed that using the probe in magnetic fields leads to a slight attenuation in sensitivity and an increase of the scintillation light yield. These data demonstrate the feasibility of combining NMR to the /spl beta/-MicroProbe.
Sukhotnik, Igor; Coran, Arnold G; Pollak, Yulia; Kuhnreich, Eviatar; Berkowitz, Drora; Saxena, Amulya K
2017-09-01
Notch signaling is thought to act to drive cell versification in the lining of the small intestine. The purpose of the present study was to evaluate the role of the Notch signaling pathway in stem cell differentiation in the late stages of intestinal adaptation after massive small bowel resection in a rat. Male Sprague-Dawley rats were randomly assigned to one of two experimental groups of eight rats each: Sham rats underwent bowel transection and reanastomosis, while SBS rats underwent 75% small bowel resection. Rats were euthanized on day 14 Illumina's Digital Gene Expression (DGE) analysis was used to determine Notch signaling gene expression profiling. Notch-related gene and protein expression was determined using real-time PCR, Western blot analysis, and immunohistochemistry. From seven investigated Notch-related (by DGE analysis) genes, six genes were upregulated in SBS vs. control animals with a relative change in gene expression level of 20% or more. A significant upregulation of Notch signaling-related genes in resected animals was accompanied by a significant increase in Notch-1 protein levels (Western blot analysis) and a significant increase in the number of Notch1 and Hes1 (target gene)-positive cells (immunohistochemistry) compared with sham animals. Evaluation of cell differentiation has shown a strong increase in total number of absorptive cells (unchanged secretory cells) compared with control rats. In conclusion, 2 wk after bowel resection in rats, stimulated Notch signaling directs the crypt cell population toward absorptive progenitors. NEW & NOTEWORTHY This study provides novel insight into the mechanisms of cell proliferation following massive small bowel resection. We show that 2 wk after bowel resection in rats, enhanced stem cell activity was associated with stimulated Notch signaling pathway. We demonstrate that activated Notch signaling cascade directs the crypt cell population toward absorptive progenitors. Copyright © 2017 the American Physiological Society.
Mokoele, Japhta M; Spencer, B Tom; van Leengoed, Leo A M G; Fasina, Folorunso O
2014-11-12
Limpopo is a very important area for pig production in terms of animal populations and contributions to transboundary animal disease spread. Emerging small-scale pig farmers (ESSPF) are being encouraged to establish operations and spread in South Africa; however, for these farmers to perform optimally, they need to understand the basics of animal agriculture and contribute to enhancing biosecurity and efficient production systems. In the present study, the limitations to efficient production amongst ESSPF were evaluated and some improvements were suggested. It was found that the ESSPF are dominated by males and include a large percentage of older persons. A total of 26.54% of these farmers have post-matriculation qualifications. Undefined and indigenous breeds still dominate their animal genetics. The animal health technicians are the preferred channels by which farmers report diseases to the authorities (52.47%) and only one out of five (20.37%) will preferably report a disease situation direct to a veterinarian. These farmers do not vaccinate their stock, and knowledge of biosecurity is poor. Antimicrobials, especially tetracyclines, are abused. Animals that are slaughtered within the community or sold at local sale points, pension pay stations and auction markets are likely candidates for disease spread. It is recommended that the younger generations are retained and incentivised in animal agriculture. Improved training on management, health, biosecurity and better market access must be provided for the ESSPF, whilst efforts should made to consolidate these farmers into small cooperatives. The current government agricultural support system will need to be reworked to benefit the resource-poor farmers. Collaborative efforts in disease reporting and management among veterinarians, animal health technicians and extension officers will become necessary. Finally, the creation of a progressive quality grading system for ESSPF should be planned by the industry and this should be attached to a reward system that will encourage these farmers to target good farming practice.
NASA Astrophysics Data System (ADS)
Choi, WooJhon; Drexler, Wolfgang; Fujimoto, James G.
Developing and validating new techniques and methods for small animal imaging is an important research area because there are many small animal models of retinal diseases such as diabetic retinopathy, age-related macular degeneration, and glaucoma [1-6]. Because the retina is a multilayered structure with distinct abnormalities occurring in different intraretinal layers at different stages of disease progression, there is a need for imaging techniques that enable visualization of these layers individually at different time points. Although postmortem histology and ultrastructural analysis can be performed for investigating microscopic changes in the retina in small animal models, this requires sacrificing animals, which makes repeated assessment of the same animal at different time points impossible and increases the number of animals required. Furthermore, some retinal processes such as neurovascular coupling cannot be fully characterized postmortem.
Small-animal dark-field radiography for pulmonary emphysema evaluation
NASA Astrophysics Data System (ADS)
Yaroshenko, Andre; Meinel, Felix G.; Hellbach, Katharina; Bech, Martin; Velroyen, Astrid; Müller, Mark; Bamberg, Fabian; Nikolaou, Konstantin; Reiser, Maximilian F.; Yildirim, Ali Ã.-.; Eickelberg, Oliver; Pfeiffer, Franz
2014-03-01
Chronic obstructive pulmonary disease (COPD) is one of the leading causes of morbidity and mortality worldwide and emphysema is one of its main components. The disorder is characterized by irreversible destruction of the alveolar walls and enlargement of distal airspaces. Despite the severe changes in the lung tissue morphology, conventional chest radiographs have only a limited sensitivity for the detection of mild to moderate emphysema. X-ray dark-field is an imaging modality that can significantly increase the visibility of lung tissue on radiographic images. The dark-field signal is generated by coherent, small-angle scattering of x-rays on the air-tissue interfaces in the lung. Therefore, morphological changes in the lung can be clearly visualized on dark-field images. This is demonstrated by a preclinical study with a small-animal emphysema model. To generate a murine model of pulmonary emphysema, a female C57BL/6N mouse was treated with a single orotracheal application of porcine pancreatic elastase (80 U/kg body weight) dissolved in phosphate-buffered saline (PBS). Control mouse received PBS. The mice were imaged using a small-animal dark-field scanner. While conventional x-ray transmission radiography images revealed only subtle indirect signs of the pulmonary disorder, the difference between healthy and emphysematous lungs could be clearly directly visualized on the dark-field images. The dose applied to the animals is compatible with longitudinal studies. The imaging results correlate well with histology. The results of this study reveal the high potential of dark-field radiography for clinical lung imaging.
NASA Astrophysics Data System (ADS)
Rangarajan, J. R.; Van Kuyck, K.; Himmelreich, U.; Nuttin, B.; Maes, F.; Suetens, P.
2011-03-01
Clinical and pre-clinical studies show that deep brain stimulation (DBS) of targeted brain regions by neurosurgical techniques ameliorate psychiatric disorder such as anorexia nervosa. Neurosurgical interventions in preclinical rodent brain are mostly accomplished manually with a 2D atlas. Considering both the large number of animals subjected to stereotactic surgical experiments and the associated imaging cost, feasibility of sophisticated pre-operative imaging based surgical path planning and/or robotic guidance is limited. Here, we spatially normalize vasculature information and assess the intra-strain variability in cerebral vasculature for a neurosurgery planning. By co-registering and subsequently building a probabilistic vasculature template in a standard space, we evaluate the risk of a user defined electrode trajectory damaging a blood vessel on its path. The use of such a method may not only be confined to DBS therapy in small animals, but also could be readily applicable to a wide range of stereotactic small animal surgeries like targeted injection of contrast agents and cell labeling applications.
Evaluation of Taterapox Virus in Small Animals.
Parker, Scott; Crump, Ryan; Hartzler, Hollyce; Buller, R Mark
2017-08-01
Taterapox virus (TATV), which was isolated from an African gerbil ( Tatera kempi ) in 1975, is the most closely related virus to variola; however, only the original report has examined its virology. We have evaluated the tropism of TATV in vivo in small animals. We found that TATV does not infect Graphiurus kelleni , a species of African dormouse, but does induce seroconversion in the Mongolian gerbil ( Meriones unguiculatus ) and in mice; however, in wild-type mice and gerbils, the virus produces an unapparent infection. Following intranasal and footpad inoculations with 1 × 10⁶ plaque forming units (PFU) of TATV, immunocompromised stat1 -/- mice showed signs of disease but did not die; however, SCID mice were susceptible to intranasal and footpad infections with 100% mortality observed by Day 35 and Day 54, respectively. We show that death is unlikely to be a result of the virus mutating to have increased virulence and that SCID mice are capable of transmitting TATV to C57BL/6 and C57BL/6 stat1 -/- animals; however, transmission did not occur from TATV inoculated wild-type or stat1 -/- mice. Comparisons with ectromelia (the etiological agent of mousepox) suggest that TATV behaves differently both at the site of inoculation and in the immune response that it triggers.
Zarghami, Niloufar; Jensen, Michael D; Talluri, Srikanth; Foster, Paula J; Chambers, Ann F; Dick, Frederick A; Wong, Eugene
2015-11-01
Small animal immobilization devices facilitate positioning of animals for reproducible imaging and accurate focal radiation therapy. In this study, the authors demonstrate the use of three-dimensional (3D) printing technology to fabricate a custom-designed mouse head restraint. The authors evaluate the accuracy of this device for the purpose of mouse brain irradiation. A mouse head holder was designed for a microCT couch using cad software and printed in an acrylic based material. Ten mice received half-brain radiation while positioned in the 3D-printed head holder. Animal placement was achieved using on-board image guidance and computerized asymmetric collimators. To evaluate the precision of beam localization for half-brain irradiation, mice were sacrificed approximately 30 min after treatment and brain sections were stained for γ-H2AX, a marker for DNA breaks. The distance and angle of the γ-H2AX radiation beam border to longitudinal fissure were measured on histological samples. Animals were monitored for any possible trauma from the device. Visualization of the radiation beam on ex vivo brain sections with γ-H2AX immunohistochemical staining showed a sharp radiation field within the tissue. Measurements showed a mean irradiation targeting error of 0.14±0.09 mm (standard deviation). Rotation between the beam axis and mouse head was 1.2°±1.0° (standard deviation). The immobilization device was easily adjusted to accommodate different sizes of mice. No signs of trauma to the mice were observed from the use of tooth block and ear bars. The authors designed and built a novel 3D-printed mouse head holder with many desired features for accurate and reproducible radiation targeting. The 3D printing technology was found to be practical and economical for producing a small animal imaging and radiation restraint device and allows for customization for study specific needs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zarghami, Niloufar, E-mail: nzargham@uwo.ca; Jensen, Michael D.; Talluri, Srikanth
Purpose: Small animal immobilization devices facilitate positioning of animals for reproducible imaging and accurate focal radiation therapy. In this study, the authors demonstrate the use of three-dimensional (3D) printing technology to fabricate a custom-designed mouse head restraint. The authors evaluate the accuracy of this device for the purpose of mouse brain irradiation. Methods: A mouse head holder was designed for a microCT couch using CAD software and printed in an acrylic based material. Ten mice received half-brain radiation while positioned in the 3D-printed head holder. Animal placement was achieved using on-board image guidance and computerized asymmetric collimators. To evaluate themore » precision of beam localization for half-brain irradiation, mice were sacrificed approximately 30 min after treatment and brain sections were stained for γ-H2AX, a marker for DNA breaks. The distance and angle of the γ-H2AX radiation beam border to longitudinal fissure were measured on histological samples. Animals were monitored for any possible trauma from the device. Results: Visualization of the radiation beam on ex vivo brain sections with γ-H2AX immunohistochemical staining showed a sharp radiation field within the tissue. Measurements showed a mean irradiation targeting error of 0.14 ± 0.09 mm (standard deviation). Rotation between the beam axis and mouse head was 1.2° ± 1.0° (standard deviation). The immobilization device was easily adjusted to accommodate different sizes of mice. No signs of trauma to the mice were observed from the use of tooth block and ear bars. Conclusions: The authors designed and built a novel 3D-printed mouse head holder with many desired features for accurate and reproducible radiation targeting. The 3D printing technology was found to be practical and economical for producing a small animal imaging and radiation restraint device and allows for customization for study specific needs.« less
Animal Model Development for the Penn State Pediatric Ventricular Assist Device
Carney, Elizabeth L.; Clark, J. Brian; Myers, John L.; Peterson, Rebecca; Wilson, Ronald P.; Weiss, William J.
2009-01-01
In March 2004, the National Heart, Lung, and Blood Institute (NHLBI) awarded five contracts to develop devices providing circulatory support for infants and small children with congenital and acquired cardiac disease. Since 2004, the team at Penn State College of Medicine has developed a pneumatically-actuated ventricular assist device (VAD) with mechanical tilting disk valves. To date, hemodynamic performance, thrombogenesis, and hemolysis have been chronically evaluated in 16 animals, including 4 pygmy goats and 12 sheep. Major complications, mainly respiratory failure, have been encountered and resolved by a multi-disciplinary team. Multi-modal analgesia, appropriate antibiotic therapy, and attentive animal care have contributed to successful outcomes. Time after implant has ranged from 0–40 days. Most recently, a sheep implanted with Version 3 Infant VAD was electively terminated at 35 days post-implant, with no major adverse events. This report describes a successful in vivo model for evaluating a pediatric VAD. PMID:19849686
Theoretical considerations on maximum running speeds for large and small animals.
Fuentes, Mauricio A
2016-02-07
Mechanical equations for fast running speeds are presented and analyzed. One of the equations and its associated model predict that animals tend to experience larger mechanical stresses in their limbs (muscles, tendons and bones) as a result of larger stride lengths, suggesting a structural restriction entailing the existence of an absolute maximum possible stride length. The consequence for big animals is that an increasingly larger body mass implies decreasing maximal speeds, given that the stride frequency generally decreases for increasingly larger animals. Another restriction, acting on small animals, is discussed only in preliminary terms, but it seems safe to assume from previous studies that for a given range of body masses of small animals, those which are bigger are faster. The difference between speed scaling trends for large and small animals implies the existence of a range of intermediate body masses corresponding to the fastest animals. Copyright © 2015 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Livesey, Dennis W.; Fong, Stephen
This small animal care course guide is designed for students who will be seeking employment in veterinary hospitals, kennels, grooming shops, pet shops, and small-animal laboratories. The guide begins with an introductory section that gives the educational philosophy of the course, job categories and opportunities, units of instruction required…
USDA-ARS?s Scientific Manuscript database
Locoweed poisoning has largely been attributed to the effects of mannosidase inhibiting swainsonine. However, there are many plants that contain mixtures of swainsonine and other glycosidase inhibiting alkaloids such as calystegines, castanospermine, and other minor alkaloids or metabolites like le...
INTERPRETATIONS AND LIMITATION OF PULMONARY FUNCTION TESTING IN SMALL LABORATORY ANIMALS
Pulmonary function tests are tools available to the researcher and clinician to evaluate the ability of the lung to perform its essential function of gas exchange. o meet this principal function, the lung needs to operate efficiently with minimal mechanical work as well as provid...
This project evaluates whether TGF beta inhibition during radiation therapy (RT) to breast cancer brain metastases (BCBM) provides greater...TNBC) brain metastasis. We provided image guided radiotherapy (IGRT) to murine BCBM using the small animal radiation research platform (SARRP) and
Eisenberg, Joseph N.S.; Trueba, Gabriel; Zhang, Lixin; Johnson, Timothy J.
2017-01-01
Summary: Small-scale food animal production is widely practiced around the globe, yet it is often overlooked in terms of the environmental health risks. Evidence suggests that small-scale food animal producers often employ the use of antimicrobials to improve the survival and growth of their animals, and that this practice leads to the development of antimicrobial resistance (AMR) that can potentially spread to humans. The nature of human–animal interactions in small-scale food animal production systems, generally practiced in and around the home, likely augments spillover events of AMR into the community on a scale that is currently unrecognized and deserves greater attention. https://doi.org/10.1289/EHP2116 PMID:29038091
Application of biological simulation models in estimating feed efficiency of finishing steers.
Williams, C B
2010-07-01
Data on individual daily feed intake, BW at 28-d intervals, and carcass composition were obtained on 1,212 crossbred steers. Within-animal regressions of cumulative feed intake and BW on linear and quadratic days on feed were used to quantify initial and ending BW, average daily observed feed intake (OFI), and ADG over a 120-d finishing period. Feed intake was predicted (PFI) with 3 biological simulation models (BSM): a) Decision Evaluator for the Cattle Industry, b) Cornell Value Discovery System, and c) NRC update 2000, using observed growth and carcass data as input. Residual feed intake (RFI) was estimated using OFI (RFI(EL)) in a linear statistical model (LSM), and feed conversion ratio (FCR) was estimated as OFI/ADG (FCR(E)). Output from the BSM was used to estimate RFI by using PFI in place of OFI with the same LSM, and FCR was estimated as PFI/ADG. These estimates were evaluated against RFI(EL) and FCR(E). In a second analysis, estimates of RFI were obtained for the 3 BSM as the difference between OFI and PFI, and these estimates were evaluated against RFI(EL). The residual variation was extremely small when PFI was used in the LSM to estimate RFI, and this was mainly due to the fact that the same input variables (initial BW, days on feed, and ADG) were used in the BSM and LSM. Hence, the use of PFI obtained with BSM as a replacement for OFI in a LSM to characterize individual animals for RFI was not feasible. This conclusion was also supported by weak correlations (<0.4) between RFI(EL) and RFI obtained with PFI in the LSM, and very weak correlations (<0.13) between RFI(EL) and FCR obtained with PFI. In the second analysis, correlations (>0.89) for RFI(EL) with the other RFI estimates suggest little difference between RFI(EL) and any of these RFI estimates. In addition, results suggest that the RFI estimates calculated with PFI would be better able to identify animals with low OFI and small ADG as inefficient compared with RFI(EL). These results may be due to the fact that computer models predict performance on an individual-animal basis in contrast to a LSM, which estimates a fixed relationship for all animals; hence, the BSM may provide RFI estimates that are closer to the true biological efficiency of animals. In addition, BSM may facilitate comparisons across different data sets and provide more accurate estimates of efficiency in small data sets where errors would be greater with a LSM.
StarScan: a web server for scanning small RNA targets from degradome sequencing data.
Liu, Shun; Li, Jun-Hao; Wu, Jie; Zhou, Ke-Ren; Zhou, Hui; Yang, Jian-Hua; Qu, Liang-Hu
2015-07-01
Endogenous small non-coding RNAs (sRNAs), including microRNAs, PIWI-interacting RNAs and small interfering RNAs, play important gene regulatory roles in animals and plants by pairing to the protein-coding and non-coding transcripts. However, computationally assigning these various sRNAs to their regulatory target genes remains technically challenging. Recently, a high-throughput degradome sequencing method was applied to identify biologically relevant sRNA cleavage sites. In this study, an integrated web-based tool, StarScan (sRNA target Scan), was developed for scanning sRNA targets using degradome sequencing data from 20 species. Given a sRNA sequence from plants or animals, our web server performs an ultrafast and exhaustive search for potential sRNA-target interactions in annotated and unannotated genomic regions. The interactions between small RNAs and target transcripts were further evaluated using a novel tool, alignScore. A novel tool, degradomeBinomTest, was developed to quantify the abundance of degradome fragments located at the 9-11th nucleotide from the sRNA 5' end. This is the first web server for discovering potential sRNA-mediated RNA cleavage events in plants and animals, which affords mechanistic insights into the regulatory roles of sRNAs. The StarScan web server is available at http://mirlab.sysu.edu.cn/starscan/. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.
Tillner, Falk; Thute, Prasad; Bütof, Rebecca; Krause, Mechthild; Enghardt, Wolfgang
2014-12-01
For translational cancer research, pre-clinical in-vivo studies using small animals have become indispensable in bridging the gap between in-vitro cell experiments and clinical implementation. When setting up such small animal experiments, various biological, technical and methodical aspects have to be considered. In this work we present a comprehensive topical review based on relevant publications on irradiation techniques used for pre-clinical cancer research in mice and rats. Clinical radiotherapy treatment devices for the application of external beam radiotherapy and brachytherapy as well as dedicated research irradiation devices are feasible for small animal irradiation depending on the animal model and the experimental goals. In this work, appropriate solutions for the technological transfer of human radiation oncology to small animal radiation research are summarised. Additionally, important information concerning the experimental design is provided such that reliable and clinically relevant results can be attained. Copyright © 2014. Published by Elsevier GmbH.
Comprehensive quality assurance phantom for the small animal radiation research platform (SARRP)
Jermoumi, M.; Korideck, H.; Bhagwat, M.; Zygmanski, P.; Makrigiogos, G.M.; Berbeco, R.I.; Cormack, R.C.; Ngwa, W.
2016-01-01
Purpose To develop and test the suitability and performance of a comprehensive quality assurance (QA) phantom for the Small Animal Radiation Research Platform (SARRP). Methods and materials A QA phantom was developed for carrying out daily, monthly and annual QA tasks including: imaging, dosimetry and treatment planning system (TPS) performance evaluation of the SARRP. The QA phantom consists of 15 (60 × 60 × 5 mm3) kV-energy tissue equivalent solid water slabs. The phantom can incorporate optically stimulated luminescence dosimeters (OSLD), Mosfet or film. One slab, with inserts and another slab with hole patterns are particularly designed for image QA. Results Output constancy measurement results showed daily variations within 3%. Using the Mosfet in phantom as target, results showed that the difference between TPS calculations and measurements was within 5%. Annual QA results for the Percentage depth dose (PDD) curves, lateral beam profiles, beam flatness and beam profile symmetry were found consistent with results obtained at commissioning. PDD curves obtained using film and OSLDs showed good agreement. Image QA was performed monthly, with image-quality parameters assessed in terms of CBCT image geometric accuracy, CT number accuracy, image spatial resolution, noise and image uniformity. Conclusions The results show that the developed QA phantom can be employed as a tool for comprehensive performance evaluation of the SARRP. The study provides a useful reference for development of a comprehensive quality assurance program for the SARRP and other similar small animal irradiators, with proposed tolerances and frequency of required tests. PMID:25964129
Comprehensive quality assurance phantom for the small animal radiation research platform (SARRP).
Jermoumi, M; Korideck, H; Bhagwat, M; Zygmanski, P; Makrigiogos, G M; Berbeco, R I; Cormack, R C; Ngwa, W
2015-07-01
To develop and test the suitability and performance of a comprehensive quality assurance (QA) phantom for the Small Animal Radiation Research Platform (SARRP). A QA phantom was developed for carrying out daily, monthly and annual QA tasks including: imaging, dosimetry and treatment planning system (TPS) performance evaluation of the SARRP. The QA phantom consists of 15 (60 × 60 × 5 mm(3)) kV-energy tissue equivalent solid water slabs. The phantom can incorporate optically stimulated luminescence dosimeters (OSLD), Mosfet or film. One slab, with inserts and another slab with hole patterns are particularly designed for image QA. Output constancy measurement results showed daily variations within 3%. Using the Mosfet in phantom as target, results showed that the difference between TPS calculations and measurements was within 5%. Annual QA results for the Percentage depth dose (PDD) curves, lateral beam profiles, beam flatness and beam profile symmetry were found consistent with results obtained at commissioning. PDD curves obtained using film and OSLDs showed good agreement. Image QA was performed monthly, with image-quality parameters assessed in terms of CBCT image geometric accuracy, CT number accuracy, image spatial resolution, noise and image uniformity. The results show that the developed QA phantom can be employed as a tool for comprehensive performance evaluation of the SARRP. The study provides a useful reference for development of a comprehensive quality assurance program for the SARRP and other similar small animal irradiators, with proposed tolerances and frequency of required tests. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
A flexible, small positron emission tomography prototype for resource-limited laboratories
NASA Astrophysics Data System (ADS)
Miranda-Menchaca, A.; Martínez-Dávalos, A.; Murrieta-Rodríguez, T.; Alva-Sánchez, H.; Rodríguez-Villafuerte, M.
2015-05-01
Modern small-animal PET scanners typically consist of a large number of detectors along with complex electronics to provide tomographic images for research in the preclinical sciences that use animal models. These systems can be expensive, especially for resource-limited educational and academic institutions in developing countries. In this work we show that a small-animal PET scanner can be built with a relatively reduced budget while, at the same time, achieving relatively high performance. The prototype consists of four detector modules each composed of LYSO pixelated crystal arrays (individual crystal elements of dimensions 1 × 1 × 10 mm3) coupled to position-sensitive photomultiplier tubes. Tomographic images are obtained by rotating the subject to complete enough projections for image reconstruction. Image quality was evaluated for different reconstruction algorithms including filtered back-projection and iterative reconstruction with maximum likelihood-expectation maximization and maximum a posteriori methods. The system matrix was computed both with geometric considerations and by Monte Carlo simulations. Prior to image reconstruction, Fourier data rebinning was used to increase the number of lines of response used. The system was evaluated for energy resolution at 511 keV (best 18.2%), system sensitivity (0.24%), spatial resolution (best 0.87 mm), scatter fraction (4.8%) and noise equivalent count-rate. The system can be scaled-up to include up to 8 detector modules, increasing detection efficiency, and its price may be reduced as newer solid state detectors become available replacing the traditional photomultiplier tubes. Prototypes like this may prove to be very valuable for educational, training, preclinical and other biological research purposes.
Day, M J; Karkare, U; Schultz, R D; Squires, R; Tsujimoto, H
2015-02-01
In 2012 and 2013, the World Small Animal Veterinary Association (WSAVA) Vaccination Guidelines Group (VGG) undertook fact-finding visits to several Asian countries, with a view to developing advice for small companion animal practitioners in Asia related to the administration of vaccines to dogs and cats. The VGG met with numerous first opinion practitioners, small animal association leaders, academic veterinarians, government regulators and industry representatives and gathered further information from a survey of almost 700 veterinarians in India, China, Japan and Thailand. Although there were substantial differences in the nature and magnitude of the challenges faced by veterinarians in each country, and also differences in the resources available to meet those challenges, overall, the VGG identified insufficient undergraduate and postgraduate training in small companion animal microbiology, immunology and vaccinology. In most of the countries, there has been little academic research into small animal infectious diseases. This, coupled with insufficient laboratory diagnostic support, has limited the growth of knowledge concerning the prevalence and circulating strains of key infectious agents in most of the countries visited. Asian practitioners continue to recognise clinical infections that are now considered uncommon or rare in western countries. In particular, canine rabies virus infection poses a continuing threat to animal and human health in this region. Both nationally manufactured and international dog and cat vaccines are variably available in the Asian countries, but the product ranges are small and dominated by multi-component vaccines with a licensed duration of immunity (DOI) of only 1 year, or no description of DOI. Asian practitioners are largely unaware of current global trends in small animal vaccinology or of the WSAVA vaccination guidelines. Consequently, most practitioners continue to deliver annual revaccination with both core and non-core vaccines to adult animals, with little understanding that "herd immunity" is more important than frequent revaccination of individual animals within the population. In this paper, the VGG presents the findings of this project and makes key recommendations for the Asian countries. The VGG recommends that (1) Asian veterinary schools review and increase as needed the amount of instruction in small animal vaccinology within their undergraduate curriculum and increase the availability of pertinent postgraduate education for practitioners; (2) national small animal veterinary associations, industry veterinarians and academic experts work together to improve the scientific evidence base concerning small animal infectious diseases and vaccination in their countries; (3) national small animal veterinary associations take leadership in providing advice to practitioners based on improved local knowledge and global vaccination guidelines; (4) licensing authorities use this enhanced evidence base to inform and support the registration of improved vaccine product ranges for use in their countries, ideally with DOI for core vaccines similar or equal to those of equivalent products available in western countries (i.e. 3 or 4 years). The VGG also endorses the efforts made by Asian governments, non-governmental organisations and veterinary practitioners in working towards the goal of global elimination of canine rabies virus infection. In this paper, the VGG offers both a current pragmatic and future aspirational approach to small animal vaccination in Asia. As part of this project, the VGG delivered continuing education to over 800 Asian practitioners at seven events in four countries. Accompanying this document is a list of 80 frequently asked questions (with answers) that arose during these discussions. The VGG believes that this information will be of particular value to Asian veterinarians as they move towards implementing global trends in small companion animal vaccinology. © 2014 WSAVA.
Exploring Small Animal Care. Teacher's Guide.
ERIC Educational Resources Information Center
Livesey, Dennis W.
This course guide in small animal care is designed to give students seeking employment in veterinary hospitals, kennels, or pet shops an opportunity to (1) develop basic skills in small animal handling, sanitation of housing, and nutrition, (2) acquire skills in dog and cat grooming, including shop operation, (3) develop attitudes which contribute…
1990-04-01
DECISION AIDS HAVE CREATED A VAST NEW POTENTIAL FOR SUPPORT OF STRATEGIC AND TACTICAL OPERATIONS. THE NON-MONOTONIC PROBABILIST (NMP), DEVELOPED BY...QUALITY OF THE NEW DESIGN WILL BE EVALUATED BY CREATING A VIDEO TAPE USING A VIDEO ANIMATION SYSTEM, AND A SOFTWARE SIMULATION OF THE NEW DESIGN. THE...FAULT TOLERANT, SECURE SHIPBOARD COMMUNICATIONS. THE LAN WILL UTILIZE PHOENIX DIGITAL’S FAULT TOLERANT, " SELF - HEALING " SMALL BUSINESS INNOVATION RESEARCH
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zeraatkar, Navid; Farahani, Mohammad Hossein; Rahmim, Arman
Purpose: Given increasing efforts in biomedical research utilizing molecular imaging methods, development of dedicated high-performance small-animal SPECT systems has been growing rapidly in the last decade. In the present work, we propose and assess an alternative concept for SPECT imaging enabling desktop open-gantry imaging of small animals. Methods: The system, PERSPECT, consists of an imaging desk, with a set of tilted detector and pinhole collimator placed beneath it. The object to be imaged is simply placed on the desk. Monte Carlo (MC) and analytical simulations were utilized to accurately model and evaluate the proposed concept and design. Furthermore, a dedicatedmore » image reconstruction algorithm, finite-aperture-based circular projections (FABCP), was developed and validated for the system, enabling more accurate modeling of the system and higher quality reconstructed images. Image quality was quantified as a function of different tilt angles in the acquisition and number of iterations in the reconstruction algorithm. Furthermore, more complex phantoms including Derenzo, Defrise, and mouse whole body were simulated and studied. Results: The sensitivity of the PERSPECT was 207 cps/MBq. It was quantitatively demonstrated that for a tilt angle of 30°, comparable image qualities were obtained in terms of normalized squared error, contrast, uniformity, noise, and spatial resolution measurements, the latter at ∼0.6 mm. Furthermore, quantitative analyses demonstrated that 3 iterations of FABCP image reconstruction (16 subsets/iteration) led to optimally reconstructed images. Conclusions: The PERSPECT, using a novel imaging protocol, can achieve comparable image quality performance in comparison with a conventional pinhole SPECT with the same configuration. The dedicated FABCP algorithm, which was developed for reconstruction of data from the PERSPECT system, can produce high quality images for small-animal imaging via accurate modeling of the system as incorporated in the forward- and back-projection steps. Meanwhile, the developed MC model and the analytical simulator of the system can be applied for further studies on development and evaluation of the system.« less
NASA Astrophysics Data System (ADS)
Alessio, R.; Nogueira, L. P.; Almeida, A. P.; Colaço, M. V.; Braz, D.; Andrade, C. B. V.; Salata, C.; Ferreira-Machado, S. C.; de Almeida, C. E.; Tromba, G.; Barroso, R. C.
2014-04-01
Three-dimensional microtomography has the potential to examine complete bones of small laboratory animals with very high resolution in a non-invasive way. One of the side effects caused by some chemotherapy drugs is the induction of amenorrhea, temporary or not, in premenopausal women, with a consequent decrease in estrogen production, which can lead to bone changes. In the present work, the femur heads of rats treated with chemotherapy drugs were evaluated by 3D histomorphometry using synchrotron radiation microcomputed tomography. Control animals were also evaluated for comparison. The 3D tomographic images were obtained at the SYRMEP (SYnchrotron Radiation for MEdical Physics) beamline at the Elettra Synchrotron Laboratory in Trieste, Italy. Results showed significant differences in morphometric parameters measured from the 3D images of femur heads of rats in both analyzed groups.
The ‘Dangerous’ Women of Animal Welfare: How British Veterinary Medicine Went to the Dogs
Gardiner, Andrew
2014-01-01
This paper examines the turn toward the small companion animal that occurred in British veterinary medicine in the twentieth century. The change in species emphasis is usually attributed to post-war socioeconomic factors, however this explanation ignores the extensive small animal treatment that was occurring outwith the veterinary profession in the interwar period. The success of this unqualified practice caused the veterinary profession to rethink attitudes to small animals (dogs initially, later cats) upon the decline of horse practice. This paper argues that a shift toward seeing the small animal as a legitimate veterinary patient was necessary before the specialty could become mainstream in the post-war years, and that this occurred between the wars as a result of the activities of British animal welfare charities, especially the People's Dispensary for Sick Animals of the Poor. PMID:25067889
Williams, David; Adeyeye, Nina; Visser, Erni
2017-01-01
In this study we aimed to examine wild European hedgehogs (Erinaceus europaeus) in rescue centres and to determine ocular abnormalities in this animal population. Three hundred animals varying in age from 2 months to 5 years were examined, 147 being male and 153 female. All animals were evaluated with direct and indirect ophthalmoscopy and slit lamp biomicroscopy in animals where lesions were detected. Tonometry using the Tonovet rebound tonometer was undertaken in selected animals as was assessment of tear production using the Schirmer I tear test. Four animals were affected by orbital infection, 3 were anophthalmic, 2 unilaterally and one bilaterally, 3 by conjunctivitis, 3 by non-ulcerative keratitis and 4 by uveitis with corneal oedema. Fifty seven animals were affected by cataract, 54 with bilateral nuclear lens opacities. Twenty six of these animals were young animals considered too small to hibernate. This report documents the first prospective study of ocular disease in the European hedgehog. The predominant finding was bilateral nuclear cataract seen particularly in young poorly growing animals. Investigation into the potential causation of cataracts by poor nutrition or poor feeding ability by lens opacification requires further study. PMID:29038778
Changes in leptospirosis etiology in animals and humans.
Vasylieva, Natalia; Andreychyn, Mykhaylo; Kravchuk, Yulia; Chervinska, Оlena; Iosyk, Iaryna
2017-12-23
Leptospirosis is endemic in Ternopil region. In Ukraine, the disease is registered in almost all regions, including the Ternopil region. The aim of the research is to study the regularities of epidemic and epizootic processes of leptospirosis, and the circulation of its pathogens among different sources (small mammals, animals) and humans. Etiologic spectrum of leptospirosis registered in Ternopil region in 1972-2016 among small mammals, farm animals and sick people was studied. Due to the analysis of pathogens circulation among different sources (small mammals, animals), as well as the annual morbidity in humans, it was proved that new leptospira serovars are endemic and brought into the regions mostly by farm animals. Farm animals introduce the infection to humans through the environment, sometimes within 3-5-years. The spread was observed of pathogen serovars, which are new in certain areas, among all types of mouse-like small mammals and rats. It was established that livestock and small mammals are parallel reservoirs. In the regions with endemic species, the structural modification in the etiology of leptospirosis in humans is caused by additional reservoirs among animals, as well as the circulation of other pathogen serovars that were absent in the main natural reservoir, i.e. mouse-like small mammals and rats. The constant monitoring of the population, contamination and carrier state of mouse-like small mammals, rats and farm animals, is required In order to predict the future epidemiological situation on leptospirosis among the population and to improve leptospirosis diagnosis.
Optimization and performance evaluation of the microPET II scanner for in vivo small-animal imaging
NASA Astrophysics Data System (ADS)
Yang, Yongfeng; Tai, Yuan-Chuan; Siegel, Stefan; Newport, Danny F.; Bai, Bing; Li, Quanzheng; Leahy, Richard M.; Cherry, Simon R.
2004-06-01
MicroPET II is a newly developed PET (positron emission tomography) scanner designed for high-resolution imaging of small animals. It consists of 17 640 LSO crystals each measuring 0.975 × 0.975 × 12.5 mm3, which are arranged in 42 contiguous rings, with 420 crystals per ring. The scanner has an axial field of view (FOV) of 4.9 cm and a transaxial FOV of 8.5 cm. The purpose of this study was to carefully evaluate the performance of the system and to optimize settings for in vivo mouse and rat imaging studies. The volumetric image resolution was found to depend strongly on the reconstruction algorithm employed and averaged 1.1 mm (1.4 µl) across the central 3 cm of the transaxial FOV when using a statistical reconstruction algorithm with accurate system modelling. The sensitivity, scatter fraction and noise-equivalent count (NEC) rate for mouse- and rat-sized phantoms were measured for different energy and timing windows. Mouse imaging was optimized with a wide open energy window (150-750 keV) and a 10 ns timing window, leading to a sensitivity of 3.3% at the centre of the FOV and a peak NEC rate of 235 000 cps for a total activity of 80 MBq (2.2 mCi) in the phantom. Rat imaging, due to the higher scatter fraction, and the activity that lies outside of the field of view, achieved a maximum NEC rate of 24 600 cps for a total activity of 80 MBq (2.2 mCi) in the phantom, with an energy window of 250-750 keV and a 6 ns timing window. The sensitivity at the centre of the FOV for these settings is 2.1%. This work demonstrates that different scanner settings are necessary to optimize the NEC count rate for different-sized animals and different injected doses. Finally, phantom and in vivo animal studies are presented to demonstrate the capabilities of microPET II for small-animal imaging studies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lalander, Cecilia Helena, E-mail: cecilia.lalander@slu.se; Komakech, Allan John; Department of Agricultural & Bio-systems Engineering, Makerere University, Kampala
Highlights: • Poor manure management can increase burden of disease and environmental impact. • A low-maintenance vermicompost reactor was set-up in Kampala, Uganda. • High material reduction (45.9%) and waste-to-biomass conversion (3.6% on a TS basis). • Five year return on investment of 275% of system in Uganda. • Technically and economically viable system for improved urban manure management. - Abstract: Inadequate organic waste management can contribute to the spread of diseases and have negative impacts on the environment. Vermicomposting organic waste could have dual beneficial effects by generating an economically viable animal feed protein in the form of wormmore » biomass, while alleviating the negative effects of poor organic waste management. In this study, a low-maintenance vermicomposting system was evaluated as manure and food waste management system for small-holder farmers. A vermicomposting system using the earthworm species Eudrilus eugeniae and treating cow manure and food waste was set up in Kampala, Uganda, and monitored for 172 days. The material degradation and protein production rates were evaluated after 63 days and at the end of the experiment. The material reduction was 45.9% and the waste-to-biomass conversion rate was 3.5% in the vermicomposting process on a total solids basis. A possible increase in the conversion rate could be achieved by increasing the frequency of worm harvesting. Vermicomposting was found to be a viable manure management method in small-scale urban animal agriculture; the return of investment was calculated to be 280% for treating the manure of a 450 kg cow. The vermicompost was not sanitised, although hygiene quality could be improved by introducing a post-stabilisation step in which no fresh material is added. The value of the animal feed protein generated in the process can act as an incentive to improve current manure management strategies.« less
NASA Astrophysics Data System (ADS)
Efthimiou, N.; Papadimitroulas, P.; Kostou, T.; Loudos, G.
2015-09-01
Commercial clinical and preclinical PET scanners rely on the full cylindrical geometry for whole body scans as well as for dedicated organs. In this study we propose the construction of a low cost dual-head C-shaped PET system dedicated for small animal brain imaging. Monte Carlo simulation studies were performed using GATE toolkit to evaluate the optimum design in terms of sensitivity, distortions in the FOV and spatial resolution. The PET model is based on SiPMs and BGO pixelated arrays. Four different configurations with C- angle 0°, 15°, 30° and 45° within the modules, were considered. Geometrical phantoms were used for the evaluation process. STIR software, extended by an efficient multi-threaded ray tracing technique, was used for the image reconstruction. The algorithm automatically adjusts the size of the FOV according to the shape of the detector's geometry. The results showed improvement in sensitivity of ∼15% in case of 45° C-angle compared to the 0° case. The spatial resolution was found 2 mm for 45° C-angle.
Computer-aided pulmonary image analysis in small animal models
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xu, Ziyue; Mansoor, Awais; Mollura, Daniel J.
Purpose: To develop an automated pulmonary image analysis framework for infectious lung diseases in small animal models. Methods: The authors describe a novel pathological lung and airway segmentation method for small animals. The proposed framework includes identification of abnormal imaging patterns pertaining to infectious lung diseases. First, the authors’ system estimates an expected lung volume by utilizing a regression function between total lung capacity and approximated rib cage volume. A significant difference between the expected lung volume and the initial lung segmentation indicates the presence of severe pathology, and invokes a machine learning based abnormal imaging pattern detection system next.more » The final stage of the proposed framework is the automatic extraction of airway tree for which new affinity relationships within the fuzzy connectedness image segmentation framework are proposed by combining Hessian and gray-scale morphological reconstruction filters. Results: 133 CT scans were collected from four different studies encompassing a wide spectrum of pulmonary abnormalities pertaining to two commonly used small animal models (ferret and rabbit). Sensitivity and specificity were greater than 90% for pathological lung segmentation (average dice similarity coefficient > 0.9). While qualitative visual assessments of airway tree extraction were performed by the participating expert radiologists, for quantitative evaluation the authors validated the proposed airway extraction method by using publicly available EXACT’09 data set. Conclusions: The authors developed a comprehensive computer-aided pulmonary image analysis framework for preclinical research applications. The proposed framework consists of automatic pathological lung segmentation and accurate airway tree extraction. The framework has high sensitivity and specificity; therefore, it can contribute advances in preclinical research in pulmonary diseases.« less
Sci-Thur AM: YIS – 08: Automated Imaging Quality Assurance for Image-Guided Small Animal Irradiators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnstone, Chris; Bazalova-Carter, Magdalena
Purpose: To develop quality assurance (QA) standards and tolerance levels for image quality of small animal irradiators. Methods: A fully automated in-house QA software for image analysis of a commercial microCT phantom was created. Quantitative analyses of CT linearity, signal-to-noise ratio (SNR), uniformity and noise, geometric accuracy, modulation transfer function (MTF), and CT number evaluation was performed. Phantom microCT scans from seven institutions acquired with varying parameters (kVp, mA, time, voxel size, and frame rate) and five irradiator units (Xstrahl SARRP, PXI X-RAD 225Cx, PXI X-RAD SmART, GE explore CT/RT 140, and GE Explore CT 120) were analyzed. Multi-institutional datamore » sets were compared using our in-house software to establish pass/fail criteria for each QA test. Results: CT linearity (R2>0.996) was excellent at all but Institution 2. Acceptable SNR (>35) and noise levels (<55HU) were obtained at four of the seven institutions, where failing scans were acquired with less than 120mAs. Acceptable MTF (>1.5 lp/mm for MTF=0.2) was obtained at all but Institution 6 due to the largest scan voxel size (0.35mm). The geometric accuracy passed (<1.5%) at five of the seven institutions. Conclusion: Our QA software can be used to rapidly perform quantitative imaging QA for small animal irradiators, accumulate results over time, and display possible changes in imaging functionality from its original performance and/or from the recommended tolerance levels. This tool will aid researchers in maintaining high image quality, enabling precise conformal dose delivery to small animals.« less
Renz, Bernhard W; Leitner, Kurt; Odermatt, Erich; Worthley, Daniel L; Angele, Martin K; Jauch, Karl-Walter; Lang, Reinhold A
2014-03-01
Intra-abdominal adhesions following surgery are a major source of morbidity and mortality including abdominal pain and small bowel obstruction. This study evaluated the safety of PVA gel (polyvinyl alcohol and carboxymethylated cellulose gel) on intestinal anastomoses and its potential effectiveness in preventing adhesions in a clinically relevant large animal model. Experiments were performed in a pig model with median laparotomy and intestinal anastomosis following small bowel resection. The primary endpoint was the safety of PVA on small intestinal anastomoses. We also measured the incidence of postoperative adhesions in PVA vs. control groups: group A (eight pigs): stapled anastomosis with PVA gel compared to group B (eight pigs), which had no PVA gel; group C (eight pigs): hand-sewn anastomosis with PVA gel compared to group B (eight pigs), which had no anti-adhesive barrier. Animals were sacrificed 14 days after surgery and analyzed. All anastomoses had a patent lumen without any stenosis. No anastomoses leaked at an intraluminal pressure of 40 cmH2O. Thus, anastomoses healed very well in both groups, regardless of whether PVA was administered. PVA-treated animals, however, had significantly fewer adhesions in the area of stapled anastomoses. The hand-sewn PVA group also had weaker adhesions and trended towards fewer adhesions to adjacent organs. These results suggest that PVA gel does not jeopardize the integrity of intestinal anastomoses. However, larger trials are needed to investigate the potential of PVA gel to prevent adhesions in gastrointestinal surgery.
Li, Wei; Liu, Xu; Zhang, Guoqian; Zhang, Linlin
2017-08-20
It has been proven that chlorogenic acids can produce anticancer effects by regulating cell cycle, inducing apoptosis, inhibiting cell growth, Notch signaling pathways are closely related to many human tumors. The aim of this study is to study the mechanism of chlorogenic acid on apoptosis of non-small lung cancer through Notch1 pathway in animal level, and hope to provide theory basis on clinical treatment and research aimed at targeting Notch1 signaling in non-small cell carcinoma (NSCLC). MTT assay was used to evaluate the A549 cell proliferation under the treatment of chlorogenic acid. The effect of chlorogenic acid on apoptotic and cell cycle were detected by flow cytometry. The animal model of A549 cell transplanted in nude was established, tumer size and weight were detected. The mRNA level of Notch1 signal pathway related facter were detected by RT-PCR; the expression of Notch1 signal pathway related facter in tumor tissue was detected by western blot. Chlorogenic acid inhibited the A549 cell proliferation. incresed cell apoptotic and cell percentagein G2/M (P<0.05), and in a dose-dependent manner. In animal model, tumer size and weight were lower than control group, the difference was statistically significant (P<0.05). The relative expression of mRNA of Notch1, VEGF, Delta4, HES1 and HEY1 were decreaced (P<0.05) in tumor tissue which treated with chlorogenic. The expression of Notch1 were decreaced, PTEN, p-PTEN, p-AKT were increced significantly in tumor tissue which treated with chlorogenic (P<0.05). Chlorogenic acid can regulate theapoptosis of non-small lung cancer through Notch pathway in animal level, which may be associated with the down-regulating the expression of VEGF and Delta4. Notch pathway may cross talk with PI3K/AKT pathway through PTEN in NSCLC.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, B; He, W; Cvetkovic, D
Purpose: The purpose of the study is to compare the volume measurement of subcutaneous tumors in mice with different imaging platforms, namely a GE MRI and a Sofie-Biosciences small animal CT scanner. Methods: A549 human lung carcinoma cells and FaDu human head and neck squamous cell carcinoma cells were implanted subcutaneously into flanks of nude mice. Three FaDu tumors and three A549 tumors were included in this study. The MRI scans were done with a GE Signa 1.5 Tesla MR scanner using a fast T2-weighted sequence (70mm FOV and 1.2mm slice thickness), while the CT scans were done with themore » CT scanner on a Sofie-Biosciences G8 PET/CT platform dedicated for small animal studies (48mm FOV and 0.2mm slice thickness). Imaging contrast agent was not used in this study. Based on the DICOM images from MRI and CT scans, the tumors were contoured with Philips DICOM Viewer and the tumor volumes were obtained by summing up the contoured area and multiplied by the slice thickness. Results: The volume measurements based on the CT scans agree reasonably with that obtained with MR images for the subcutaneous tumors. The mean difference in the absolute tumor volumes between MRI- and CT-based measurements was found to be −6.2% ± 1.0%, with the difference defined as (VMR – VCT)*100%/VMR. Furthermore, we evaluated the normalized tumor volumes, which were defined for each tumor as V/V{sub 0} where V{sub 0} stands for the volume from the first MR or CT scan. The mean difference in the normalized tumor volumes was found to be 0.10% ± 0.96%. Conclusion: Despite the fact that the difference between normal and abnormal tissues is often less clear on small animal CT images than on MR images, one can still obtain reasonable tumor volume information with the small animal CT scans for subcutaneous murine xenograft models.« less
Evaluation of dog owners' perceptions concerning radiation therapy
Denneberg, Nanna Åkerlund; Egenvall, Agneta
2009-01-01
Background External radiation therapy (RT) has been available for small animals in Sweden since 2006. This study was designed to obtain information on owner experiences and perceptions related to RT of cancer in their dogs. Another survey was used to determine the attitudes about use of RT in a group of Swedish veterinarians. Their responses were analyzed and compared to their level of knowledge of oncology and RT. Methods Owners of all dogs (n = 23) who had undergone RT for malignancy at Jönköping Small Animal Hospital between March 2006 to September 2007 were interviewed. A questionnaire was given to a selected group of veterinarians. Results All 23 owners responded. All owners thought that their dog did well during RT and most that their dog was also fine during the following phase when acute RT-related skin reactions occur and heal. Three owners stated that their dog had pain that negatively impacted quality of life because of radiation dermatitis. Five owners reported that RT positively impacted quality of life of the dog during the first weeks after RT because palliation was achieved. The owners were not disturbed by the efforts required of them. All but one owner (22 of 23) stated that they would make the same decision about RT again if a similar situation occurred. The most important factor for this decision was the chance to delay occurrence of tumour-related discomfort. The chance for cure was of less importance but still essential, followed by expected side effects. Time commitments, travel, number of treatments required and financial cost; all had low impact. The veterinarian survey showed that less background knowledge of small animal oncology/RT was associated with more negative expectations of RT for small animals. Conclusion The results show that for these owners, RT was a worthwhile treatment modality and that the discomfort for the dog was manageable and acceptable relative to the benefits. Improved continuing education about small animal RT in Sweden will likely result in increased evidence-based and positive treatment recommendations concerning RT by veterinarians. PMID:19402904
9 CFR 327.16 - Small importations for importer's own consumption; requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Small importations for importer's own consumption; requirements. 327.16 Section 327.16 Animals and Animal Products FOOD SAFETY AND INSPECTION... of this part but subject to applicable requirements under other laws, including the regulations in...
9 CFR 381.207 - Small importations for consignee's personal use, display, or laboratory analysis.
Code of Federal Regulations, 2010 CFR
2010-01-01
... MEAT AND POULTRY PRODUCTS INSPECTION AND VOLUNTARY INSPECTION AND CERTIFICATION POULTRY PRODUCTS... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Small importations for consignee's personal use, display, or laboratory analysis. 381.207 Section 381.207 Animals and Animal Products FOOD...
NASA Astrophysics Data System (ADS)
Lajtos, Imre; Czernin, Johannes; Dahlbom, Magnus; Daver, Freddie; Emri, Miklos; Farshchi-Heydari, Salman; Forgacs, Attila; Hoh, Carl K.; Joszai, Istvan; Krizsan, Aron K.; Lantos, Judit; Major, Peter; Molnar, Jozsef; Opposits, Gabor; Tron, Lajos; Vera, David R.; Balkay, Laszlo
2014-06-01
The contrast recovery coefficients (CRC) were evaluated for five different small animal PET scanners: GE Explore Vista, Genisys4, MiniPET-2, nanoScan PC and Siemens Inveon. The NEMA NU-4 2008 performance test with the suggested image quality phantom (NU4IQ) does not allow the determination of the CRC values for the hot regions in the phantom. This drawback of NU4IQ phantom motivated us to develop a new method for this purpose. The method includes special acquisition and reconstruction protocols using the original phantom, and results in an artificially merged image enabling the evaluation of CRC values. An advantageous feature of this method is that it stops the cold wall effect from distorting the CRC calculation. Our suggested protocol results in a set of CRC values contributing to the characterization of small animal PET scanners. GATE simulations were also performed to validate the new method and verify the evaluated CRC values. We also demonstrated that the numerical values of this parameter depend on the actual object contrast of the hot region(s) and this mainly comes from the spillover effect. This effect was also studied while analysing the background activity level around the hot rods. We revealed that the calculated background mean values depended on the target contrast in a scanner specific manner. Performing the artificially merged imaging procedure and additional simulations using the micro hollow sphere (MHS) phantom geometry, we also proved that the inactive wall around the hot spheres can have a remarkable impact on the calculated CRC. In conclusion, we have shown that the proposed artificial merging procedure and the commonly used NU4IQ phantom prescribed by the NEMA NU-4 can easily deliver reliable CRC data otherwise unavailable for the NU4IQ phantom in the conventional protocol or the MHS phantom.
Lajtos, Imre; Czernin, Johannes; Dahlbom, Magnus; Daver, Freddie; Emri, Miklos; Farshchi-Heydari, Salman; Forgacs, Attila; Hoh, Carl K; Joszai, Istvan; Krizsan, Aron K; Lantos, Judit; Major, Peter; Molnar, Jozsef; Opposits, Gabor; Tron, Lajos; Vera, David R; Balkay, Laszlo
2014-06-07
The contrast recovery coefficients (CRC) were evaluated for five different small animal PET scanners: GE Explore Vista, Genisys4, MiniPET-2, nanoScan PC and Siemens Inveon. The NEMA NU-4 2008 performance test with the suggested image quality phantom (NU4IQ) does not allow the determination of the CRC values for the hot regions in the phantom. This drawback of NU4IQ phantom motivated us to develop a new method for this purpose. The method includes special acquisition and reconstruction protocols using the original phantom, and results in an artificially merged image enabling the evaluation of CRC values. An advantageous feature of this method is that it stops the cold wall effect from distorting the CRC calculation. Our suggested protocol results in a set of CRC values contributing to the characterization of small animal PET scanners. GATE simulations were also performed to validate the new method and verify the evaluated CRC values. We also demonstrated that the numerical values of this parameter depend on the actual object contrast of the hot region(s) and this mainly comes from the spillover effect. This effect was also studied while analysing the background activity level around the hot rods. We revealed that the calculated background mean values depended on the target contrast in a scanner specific manner. Performing the artificially merged imaging procedure and additional simulations using the micro hollow sphere (MHS) phantom geometry, we also proved that the inactive wall around the hot spheres can have a remarkable impact on the calculated CRC. In conclusion, we have shown that the proposed artificial merging procedure and the commonly used NU4IQ phantom prescribed by the NEMA NU-4 can easily deliver reliable CRC data otherwise unavailable for the NU4IQ phantom in the conventional protocol or the MHS phantom.
Cardinale, Jens; Schäfer, Martin; Benešová, Martina; Bauder-Wüst, Ulrike; Leotta, Karin; Eder, Matthias; Neels, Oliver C; Haberkorn, Uwe; Giesel, Frederik L; Kopka, Klaus
2017-03-01
In recent years, several radiotracers targeting the prostate-specific membrane antigen (PSMA) have been introduced. Some of them have had a high clinical impact on the treatment of patients with prostate cancer. However, the number of 18 F-labeled tracers addressing PSMA is still limited. Therefore, we aimed to develop a radiofluorinated molecule resembling the structure of therapeutic PSMA-617. Methods: The nonradioactive reference compound PSMA-1007 and the precursor were produced by solid-phase chemistry. The radioligand 18 F-PSMA-1007 was produced by a 2-step procedure with the prosthetic group 6- 18 F-fluoronicotinic acid 2,3,5,6-tetrafluorophenyl ester. The binding affinity of the ligand for PSMA and its internalization properties were evaluated in vitro with PSMA-positive LNCaP (lymph node carcinoma of the prostate) cells. Further, organ distribution studies were performed with mice bearing LNCaP and PC-3 (prostate cancer cell line; PSMA-negative) tumors. Finally, small-animal PET imaging of an LNCaP tumor-bearing mouse was performed. Results: The identified ligand had a binding affinity of 6.7 ± 1.7 nM for PSMA and an exceptionally high internalization ratio (67% ± 13%) in vitro. In organ distribution studies, high and specific tumor uptake (8.0 ± 2.4 percentage injected dose per gram) in LNCaP tumor-bearing mice was observed. In the small-animal PET experiments, LNCaP tumors were clearly visualized. Conclusion: The radiofluorinated PSMA ligand showed promising characteristics in its preclinical evaluation, and the feasibility of prostate cancer imaging was demonstrated by small-animal PET studies. Therefore, we recommend clinical transfer of the radioligand 18 F-PSMA-1007 for use as a diagnostic PET tracer in prestaging and monitoring of prostate cancer. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
Bagci, Ulas; Foster, Brent; Miller-Jaster, Kirsten; Luna, Brian; Dey, Bappaditya; Bishai, William R; Jonsson, Colleen B; Jain, Sanjay; Mollura, Daniel J
2013-07-23
Infectious diseases are the second leading cause of death worldwide. In order to better understand and treat them, an accurate evaluation using multi-modal imaging techniques for anatomical and functional characterizations is needed. For non-invasive imaging techniques such as computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET), there have been many engineering improvements that have significantly enhanced the resolution and contrast of the images, but there are still insufficient computational algorithms available for researchers to use when accurately quantifying imaging data from anatomical structures and functional biological processes. Since the development of such tools may potentially translate basic research into the clinic, this study focuses on the development of a quantitative and qualitative image analysis platform that provides a computational radiology perspective for pulmonary infections in small animal models. Specifically, we designed (a) a fast and robust automated and semi-automated image analysis platform and a quantification tool that can facilitate accurate diagnostic measurements of pulmonary lesions as well as volumetric measurements of anatomical structures, and incorporated (b) an image registration pipeline to our proposed framework for volumetric comparison of serial scans. This is an important investigational tool for small animal infectious disease models that can help advance researchers' understanding of infectious diseases. We tested the utility of our proposed methodology by using sequentially acquired CT and PET images of rabbit, ferret, and mouse models with respiratory infections of Mycobacterium tuberculosis (TB), H1N1 flu virus, and an aerosolized respiratory pathogen (necrotic TB) for a total of 92, 44, and 24 scans for the respective studies with half of the scans from CT and the other half from PET. Institutional Administrative Panel on Laboratory Animal Care approvals were obtained prior to conducting this research. First, the proposed computational framework registered PET and CT images to provide spatial correspondences between images. Second, the lungs from the CT scans were segmented using an interactive region growing (IRG) segmentation algorithm with mathematical morphology operations to avoid false positive (FP) uptake in PET images. Finally, we segmented significant radiotracer uptake from the PET images in lung regions determined from CT and computed metabolic volumes of the significant uptake. All segmentation processes were compared with expert radiologists' delineations (ground truths). Metabolic and gross volume of lesions were automatically computed with the segmentation processes using PET and CT images, and percentage changes in those volumes over time were calculated. (Continued on next page)(Continued from previous page) Standardized uptake value (SUV) analysis from PET images was conducted as a complementary quantitative metric for disease severity assessment. Thus, severity and extent of pulmonary lesions were examined through both PET and CT images using the aforementioned quantification metrics outputted from the proposed framework. Each animal study was evaluated within the same subject class, and all steps of the proposed methodology were evaluated separately. We quantified the accuracy of the proposed algorithm with respect to the state-of-the-art segmentation algorithms. For evaluation of the segmentation results, dice similarity coefficient (DSC) as an overlap measure and Haussdorf distance as a shape dissimilarity measure were used. Significant correlations regarding the estimated lesion volumes were obtained both in CT and PET images with respect to the ground truths (R2=0.8922,p<0.01 and R2=0.8664,p<0.01, respectively). The segmentation accuracy (DSC (%)) was 93.4±4.5% for normal lung CT scans and 86.0±7.1% for pathological lung CT scans. Experiments showed excellent agreements (all above 85%) with expert evaluations for both structural and functional imaging modalities. Apart from quantitative analysis of each animal, we also qualitatively showed how metabolic volumes were changing over time by examining serial PET/CT scans. Evaluation of the registration processes was based on precisely defined anatomical landmark points by expert clinicians. An average of 2.66, 3.93, and 2.52 mm errors was found in rabbit, ferret, and mouse data (all within the resolution limits), respectively. Quantitative results obtained from the proposed methodology were visually related to the progress and severity of the pulmonary infections as verified by the participating radiologists. Moreover, we demonstrated that lesions due to the infections were metabolically active and appeared multi-focal in nature, and we observed similar patterns in the CT images as well. Consolidation and ground glass opacity were the main abnormal imaging patterns and consistently appeared in all CT images. We also found that the gross and metabolic lesion volume percentage follow the same trend as the SUV-based evaluation in the longitudinal analysis. We explored the feasibility of using PET and CT imaging modalities in three distinct small animal models for two diverse pulmonary infections. We concluded from the clinical findings, derived from the proposed computational pipeline, that PET-CT imaging is an invaluable hybrid modality for tracking pulmonary infections longitudinally in small animals and has great potential to become routinely used in clinics. Our proposed methodology showed that automated computed-aided lesion detection and quantification of pulmonary infections in small animal models are efficient and accurate as compared to the clinical standard of manual and semi-automated approaches. Automated analysis of images in pre-clinical applications can increase the efficiency and quality of pre-clinical findings that ultimately inform downstream experimental design in human clinical studies; this innovation will allow researchers and clinicians to more effectively allocate study resources with respect to research demands without compromising accuracy.
Weese, J S; Peregrine, A S; Armstrong, J
2002-08-01
Zoonotic diseases are an ever-present concern in small animal veterinary practice and are often overlooked. A variety of nonparasitic zoonotic diseases may be encountered in small animal practice, including cat scratch disease (bartonellosis), cat bite abscesses, rabies, leptospirosis, methicillin-resistant Staphylococcus aureus, Clostridium difficile-associated diarrhea, salmonellosis, avian chlamydiosis, campylobacteriosis, dermatophytosis, and blastomycosis. These may cause human disease ranging from mild and self-limiting to fatal. The risk of development of a zoonotic disease can be lessened by early recognition of infected animals, proper animal handling, basic biosecurity precautions, and, most importantly, personal hygiene.
Pneumonic plague pathogenesis and immunity in Brown Norway rats.
Anderson, Deborah M; Ciletti, Nancy A; Lee-Lewis, Hanni; Elli, Derek; Segal, Joshua; DeBord, Kristin L; Overheim, Katie A; Tretiakova, Maria; Brubaker, Robert R; Schneewind, Olaf
2009-03-01
The Brown Norway rat was recently described as a bubonic plague model that closely mimics human disease. We therefore evaluated the Brown Norway rat as an alternative small animal model for pneumonic plague and characterized both the efficacy and potency of vaccine candidates. When infected by intranasal instillation, these rats rapidly developed fatal pneumonic plague within 2 to 4 days of infection. Plague disease was characterized by severe alveolar edema and vascular hemorrhage in the lung in addition to fulminant necrotizing pneumonia caused by massive bacterial replication and inflammation. Twenty-four hours before death, animals developed systemic disease with an apparent delayed inflammatory response. We evaluated the ability of the protective antigen, LcrV, and a mutant derivative, V10, to protect these rats from pneumonic plague. Both were highly effective vaccines because complete protection was observed at challenge doses of 7500 LD(50). Antibody analyses suggested stronger potency of V10 immune sera compared with LcrV in the passive transfer of immunity to bubonic plague, with multiple neutralizing epitopes in LcrV. Taken together, these data demonstrate the effectiveness of inhibiting type III secretion in the prevention of pneumonic plague in rats and reveal critical contributions from both the cellular and humoral immune systems. Thus, the Brown Norway rat is an appealing alternative small animal model for the study of pneumonic plague pathogenesis and immunity.
Marcinkowski, Radosław; Mollet, Pieter; Van Holen, Roel; Vandenberghe, Stefaan
2016-03-07
The mouse model is widely used in a vast range of biomedical and preclinical studies. Thanks to the ability to detect and quantify biological processes at the molecular level in vivo, PET has become a well-established tool in these investigations. However, the need to visualize and quantify radiopharmaceuticals in anatomic structures of millimetre or less requires good spatial resolution and sensitivity from small-animal PET imaging systems.In previous work we have presented a proof-of-concept of a dedicated high-resolution small-animal PET scanner based on thin monolithic scintillator crystals and Digital Photon Counter photosensor. The combination of thin monolithic crystals and MLE positioning algorithm resulted in an excellent spatial resolution of 0.7 mm uniform in the entire field of view (FOV). However, the limitation of the scanner was its low sensitivity due to small thickness of the lutetium-yttrium oxyorthosilicate (LYSO) crystals (2 mm).Here we present an improved detector design for a small-animal PET system that simultaneously achieves higher sensitivity and sustains a sub-millimetre spatial resolution. The proposed detector consists of a 5 mm thick monolithic LYSO crystal optically coupled to a Digital Photon Counter. Mean nearest neighbour (MNN) positioning combined with depth of interaction (DOI) decoding was employed to achieve sub-millimetre spatial resolution. To evaluate detector performance the intrinsic spatial resolution, energy resolution and coincidence resolving time (CRT) were measured. The average intrinsic spatial resolution of the detector was 0.60 mm full-width-at-half-maximum (FWHM). A DOI resolution of 1.66 mm was achieved. The energy resolution was 23% FWHM at 511 keV and CRT of 529 ps were measured. The improved detector design overcomes the sensitivity limitation of the previous design by increasing the nominal sensitivity of the detector block and retains an excellent intrinsic spatial resolution.
Percutaneous radiofrequency ablation of lung tumors in a large animal model.
Ahrar, Kamran; Price, Roger E; Wallace, Michael J; Madoff, David C; Gupta, Sanjay; Morello, Frank A; Wright, Kenneth C
2003-08-01
Percutaneous radiofrequency ablation (RFA) is accepted therapy for liver tumors in the appropriate clinical setting, but its use in lung neoplasms remains investigational. We undertook this study to evaluate the feasibility and immediate effectiveness of RFA for treatment of both solitary pulmonary nodules and clusters of lung tumors in a large animal model. Percutaneous RFA of 14 lung tumors in five dogs was performed under CT guidance. Animals were euthanatized 8-48 hours after the procedure. The lungs and adjacent structures were harvested for gross and histopathologic evaluation. Five solitary pulmonary nodules (range, 17-26 mm) and three clusters of three nodules each (range, 7-17 mm per nodule) were treated with RFA. All ablations were technically successful. Perilesional ground-glass opacity and small asymptomatic pneumothoraces (n = 4) were visualized during the RFA sessions. One dog developed a large pneumothorax treated with tube thoracostomy but was euthanatized 8 hours post-RFA for persistent pneumothorax and continued breathing difficulty. Follow-up CT 48 hours post-RFA revealed opacification of the whole lung segment. Gross and histopathologic evaluation showed complete thermal coagulation necrosis of all treated lesions without evidence of any viable tumor. The region of thermal coagulation necrosis typically extended to the lung surface. Small regions of pulmonary hemorrhage and congestion often surrounded the areas of coagulation necrosis. RFA can be used to treat both solitary pulmonary nodules and clusters of tumor nodules in the canine lung tumor model. This model may be useful for development of specific RFA protocols for human lung tumors.
Zahabiun, Farzaneh; Sadjjadi, Seyed Mahmoud; Esfandiari, Farideh
2015-01-01
Permanent slide preparation of nematodes especially small ones is time consuming, difficult and they become scarious margins. Regarding this problem, a modified double glass mounting method was developed and compared with classic method. A total of 209 nematode samples from human and animal origin were fixed and stained with Formaldehyde Alcohol Azocarmine Lactophenol (FAAL) followed by double glass mounting and classic dehydration method using Canada balsam as their mounting media. The slides were evaluated in different dates and times, more than four years. Different photos were made with different magnification during the evaluation time. The double glass mounting method was stable during this time and comparable with classic method. There were no changes in morphologic structures of nematodes using double glass mounting method with well-defined and clear differentiation between different organs of nematodes in this method. Using this method is cost effective and fast for mounting of small nematodes comparing to classic method.
ZAHABIUN, Farzaneh; SADJJADI, Seyed Mahmoud; ESFANDIARI, Farideh
2015-01-01
Background: Permanent slide preparation of nematodes especially small ones is time consuming, difficult and they become scarious margins. Regarding this problem, a modified double glass mounting method was developed and compared with classic method. Methods: A total of 209 nematode samples from human and animal origin were fixed and stained with Formaldehyde Alcohol Azocarmine Lactophenol (FAAL) followed by double glass mounting and classic dehydration method using Canada balsam as their mounting media. The slides were evaluated in different dates and times, more than four years. Different photos were made with different magnification during the evaluation time. Results: The double glass mounting method was stable during this time and comparable with classic method. There were no changes in morphologic structures of nematodes using double glass mounting method with well-defined and clear differentiation between different organs of nematodes in this method. Conclusion: Using this method is cost effective and fast for mounting of small nematodes comparing to classic method. PMID:26811729
Chen, Chia-Lin; Wang, Yuchuan; Lee, Jason J. S.; Tsui, Benjamin M. W.
2011-01-01
Purpose We assessed the quantitation accuracy of small animal pinhole single photon emission computed tomography (SPECT) under the current preclinical settings, where image compensations are not routinely applied. Procedures The effects of several common image-degrading factors and imaging parameters on quantitation accuracy were evaluated using Monte-Carlo simulation methods. Typical preclinical imaging configurations were modeled, and quantitative analyses were performed based on image reconstructions without compensating for attenuation, scatter, and limited system resolution. Results Using mouse-sized phantom studies as examples, attenuation effects alone degraded quantitation accuracy by up to −18% (Tc-99m or In-111) or −41% (I-125). The inclusion of scatter effects changed the above numbers to −12% (Tc-99m or In-111) and −21% (I-125), respectively, indicating the significance of scatter in quantitative I-125 imaging. Region-of-interest (ROI) definitions have greater impacts on regional quantitation accuracy for small sphere sources as compared to attenuation and scatter effects. For the same ROI, SPECT acquisitions using pinhole apertures of different sizes could significantly affect the outcome, whereas the use of different radii-of-rotation yielded negligible differences in quantitation accuracy for the imaging configurations simulated. Conclusions We have systematically quantified the influence of several factors affecting the quantitation accuracy of small animal pinhole SPECT. In order to consistently achieve accurate quantitation within 5% of the truth, comprehensive image compensation methods are needed. PMID:19048346
From the microworld to King Kong
NASA Astrophysics Data System (ADS)
Duvivier, Damien; Wautelet, Michel
2006-09-01
The microworld inspires and fascinates many people. The behaviour of small animals in that miniature world differs from that of 'large' ones in the macroworld. For some people, the capacities of small animals are nearly miraculous. If we could imitate these small beings, our capabilities would increase many times over. Unfortunately, this is not reality. The behaviour of small animals is not miraculous. It is the aim of this paper to show why this is the case by taking into account so-called scaling laws, which allow us to deal with some science-fiction stories. These same scaling laws are used to study the morphology of the giant fictional animal King Kong.
Evaluation of Matrix9 silicon photomultiplier array for small-animal PET.
Du, Junwei; Schmall, Jeffrey P; Yang, Yongfeng; Di, Kun; Roncali, Emilie; Mitchell, Gregory S; Buckley, Steve; Jackson, Carl; Cherry, Simon R
2015-02-01
The MatrixSL-9-30035-OEM (Matrix9) from SensL is a large-area silicon photomultiplier (SiPM) photodetector module consisting of a 3 × 3 array of 4 × 4 element SiPM arrays (total of 144 SiPM pixels) and incorporates SensL's front-end electronics board and coincidence board. Each SiPM pixel measures 3.16 × 3.16 mm(2) and the total size of the detector head is 47.8 × 46.3 mm(2). Using 8 × 8 polished LSO/LYSO arrays (pitch 1.5 mm) the performance of this detector system (SiPM array and readout electronics) was evaluated with a view for its eventual use in small-animal positron emission tomography (PET). Measurements of noise, signal, signal-to-noise ratio, energy resolution, flood histogram quality, timing resolution, and array trigger error were obtained at different bias voltages (28.0-32.5 V in 0.5 V intervals) and at different temperatures (5 °C-25 °C in 5 °C degree steps) to find the optimal operating conditions. The best measured signal-to-noise ratio and flood histogram quality for 511 keV gamma photons were obtained at a bias voltage of 30.0 V and a temperature of 5 °C. The energy resolution and timing resolution under these conditions were 14.2% ± 0.1% and 4.2 ± 0.1 ns, respectively. The flood histograms show that all the crystals in the 1.5 mm pitch LSO array can be clearly identified and that smaller crystal pitches can also be resolved. Flood histogram quality was also calculated using different center of gravity based positioning algorithms. Improved and more robust results were achieved using the local 9 pixels for positioning along with an energy offset calibration. To evaluate the front-end detector readout, and multiplexing efficiency, an array trigger error metric is introduced and measured at different lower energy thresholds. Using a lower energy threshold greater than 150 keV effectively eliminates any mispositioning between SiPM arrays. In summary, the Matrix9 detector system can resolve high-resolution scintillator arrays common in small-animal PET with adequate energy resolution and timing resolution over a large detector area. The modular design of the Matrix9 detector allows it to be used as a building block for simple, low channel-count, yet high performance, small animal PET or PET/MRI systems.
Evaluation of Matrix9 silicon photomultiplier array for small-animal PET
Du, Junwei; Schmall, Jeffrey P.; Yang, Yongfeng; Di, Kun; Roncali, Emilie; Mitchell, Gregory S.; Buckley, Steve; Jackson, Carl; Cherry, Simon R.
2015-01-01
Purpose: The MatrixSL-9-30035-OEM (Matrix9) from SensL is a large-area silicon photomultiplier (SiPM) photodetector module consisting of a 3 × 3 array of 4 × 4 element SiPM arrays (total of 144 SiPM pixels) and incorporates SensL’s front-end electronics board and coincidence board. Each SiPM pixel measures 3.16 × 3.16 mm2 and the total size of the detector head is 47.8 × 46.3 mm2. Using 8 × 8 polished LSO/LYSO arrays (pitch 1.5 mm) the performance of this detector system (SiPM array and readout electronics) was evaluated with a view for its eventual use in small-animal positron emission tomography (PET). Methods: Measurements of noise, signal, signal-to-noise ratio, energy resolution, flood histogram quality, timing resolution, and array trigger error were obtained at different bias voltages (28.0–32.5 V in 0.5 V intervals) and at different temperatures (5 °C–25 °C in 5 °C degree steps) to find the optimal operating conditions. Results: The best measured signal-to-noise ratio and flood histogram quality for 511 keV gamma photons were obtained at a bias voltage of 30.0 V and a temperature of 5 °C. The energy resolution and timing resolution under these conditions were 14.2% ± 0.1% and 4.2 ± 0.1 ns, respectively. The flood histograms show that all the crystals in the 1.5 mm pitch LSO array can be clearly identified and that smaller crystal pitches can also be resolved. Flood histogram quality was also calculated using different center of gravity based positioning algorithms. Improved and more robust results were achieved using the local 9 pixels for positioning along with an energy offset calibration. To evaluate the front-end detector readout, and multiplexing efficiency, an array trigger error metric is introduced and measured at different lower energy thresholds. Using a lower energy threshold greater than 150 keV effectively eliminates any mispositioning between SiPM arrays. Conclusions: In summary, the Matrix9 detector system can resolve high-resolution scintillator arrays common in small-animal PET with adequate energy resolution and timing resolution over a large detector area. The modular design of the Matrix9 detector allows it to be used as a building block for simple, low channel-count, yet high performance, small animal PET or PET/MRI systems. PMID:25652479
Evaluation of Matrix9 silicon photomultiplier array for small-animal PET
DOE Office of Scientific and Technical Information (OSTI.GOV)
Du, Junwei, E-mail: jwdu@ucdavis.edu; Schmall, Jeffrey P.; Yang, Yongfeng
Purpose: The MatrixSL-9-30035-OEM (Matrix9) from SensL is a large-area silicon photomultiplier (SiPM) photodetector module consisting of a 3 × 3 array of 4 × 4 element SiPM arrays (total of 144 SiPM pixels) and incorporates SensL’s front-end electronics board and coincidence board. Each SiPM pixel measures 3.16 × 3.16 mm{sup 2} and the total size of the detector head is 47.8 × 46.3 mm{sup 2}. Using 8 × 8 polished LSO/LYSO arrays (pitch 1.5 mm) the performance of this detector system (SiPM array and readout electronics) was evaluated with a view for its eventual use in small-animal positron emission tomographymore » (PET). Methods: Measurements of noise, signal, signal-to-noise ratio, energy resolution, flood histogram quality, timing resolution, and array trigger error were obtained at different bias voltages (28.0–32.5 V in 0.5 V intervals) and at different temperatures (5 °C–25 °C in 5 °C degree steps) to find the optimal operating conditions. Results: The best measured signal-to-noise ratio and flood histogram quality for 511 keV gamma photons were obtained at a bias voltage of 30.0 V and a temperature of 5 °C. The energy resolution and timing resolution under these conditions were 14.2% ± 0.1% and 4.2 ± 0.1 ns, respectively. The flood histograms show that all the crystals in the 1.5 mm pitch LSO array can be clearly identified and that smaller crystal pitches can also be resolved. Flood histogram quality was also calculated using different center of gravity based positioning algorithms. Improved and more robust results were achieved using the local 9 pixels for positioning along with an energy offset calibration. To evaluate the front-end detector readout, and multiplexing efficiency, an array trigger error metric is introduced and measured at different lower energy thresholds. Using a lower energy threshold greater than 150 keV effectively eliminates any mispositioning between SiPM arrays. Conclusions: In summary, the Matrix9 detector system can resolve high-resolution scintillator arrays common in small-animal PET with adequate energy resolution and timing resolution over a large detector area. The modular design of the Matrix9 detector allows it to be used as a building block for simple, low channel-count, yet high performance, small animal PET or PET/MRI systems.« less
The evolution of juvenile animal testing for small and large molecules.
Baldrick, Paul
2013-11-01
Recent formalised regulatory requirements for ensuring safe use of new drugs in children has increased the requirement, when considered relevant, to perform juvenile animal testing before commencing paediatric clinical trials. A key goal of this work is to identify or examine for a developmental or toxicity finding not seen in other toxicology testing. With our current knowledge, this paper examines what types of testing are occurring, what novel findings are being seen and their relevance in the safety evaluation process. Furthermore, trends for now and the future in the type of juvenile animal testing will be described including a need for more focused study designs and more published data on modern cross-species postnatal development. Copyright © 2013 Elsevier Inc. All rights reserved.
Waspe, Adam C; McErlain, David D; Pitelka, Vasek; Holdsworth, David W; Lacefield, James C; Fenster, Aaron
2010-04-01
Preclinical research protocols often require insertion of needles to specific targets within small animal brains. To target biologically relevant locations in rodent brains more effectively, a robotic device has been developed that is capable of positioning a needle along oblique trajectories through a single burr hole in the skull under volumetric microcomputed tomography (micro-CT) guidance. An x-ray compatible stereotactic frame secures the head throughout the procedure using a bite bar, nose clamp, and ear bars. CT-to-robot registration enables structures identified in the image to be mapped to physical coordinates in the brain. Registration is accomplished by injecting a barium sulfate contrast agent as the robot withdraws the needle from predefined points in a phantom. Registration accuracy is affected by the robot-positioning error and is assessed by measuring the surface registration error for the fiducial and target needle tracks (FRE and TRE). This system was demonstrated in situ by injecting 200 microm tungsten beads into rat brains along oblique trajectories through a single burr hole on the top of the skull under micro-CT image guidance. Postintervention micro-CT images of each skull were registered with preintervention high-field magnetic resonance images of the brain to infer the anatomical locations of the beads. Registration using four fiducial needle tracks and one target track produced a FRE and a TRE of 96 and 210 microm, respectively. Evaluation with tissue-mimicking gelatin phantoms showed that locations could be targeted with a mean error of 154 +/- 113 microm. The integration of a robotic needle-positioning device with volumetric micro-CT image guidance should increase the accuracy and reduce the invasiveness of stereotactic needle interventions in small animals.
Dosimetry in small-animal CT using Monte Carlo simulations
NASA Astrophysics Data System (ADS)
Lee, C.-L.; Park, S.-J.; Jeon, P.-H.; Jo, B.-D.; Kim, H.-J.
2016-01-01
Small-animal computed tomography (micro-CT) imaging devices are increasingly being used in biological research. While investigators are mainly interested in high-contrast, low-noise, and high-resolution anatomical images, relatively large radiation doses are required, and there is also growing concern over the radiological risk from preclinical experiments. This study was conducted to determine the radiation dose in a mouse model for dosimetric estimates using the GEANT4 application for tomographic emission simulations (GATE) and to extend its techniques to various small-animal CT applications. Radiation dose simulations were performed with the same parameters as those for the measured micro-CT data, using the MOBY phantom, a pencil ion chamber and an electrometer with a CT detector. For physical validation of radiation dose, absorbed dose of brain and liver in mouse were evaluated to compare simulated results with physically measured data using thermoluminescent dosimeters (TLDs). The mean difference between simulated and measured data was less than 2.9% at 50 kVp X-ray source. The absorbed doses of 37 brain tissues and major organs of the mouse were evaluated according to kVp changes. The absorbed dose over all of the measurements in the brain (37 types of tissues) consistently increased and ranged from 42.4 to 104.0 mGy. Among the brain tissues, the absorbed dose of the hypothalamus (157.8-414.30 mGy) was the highest for the beams at 50-80 kVp, and that of the corpus callosum (11.2-26.6 mGy) was the lowest. These results can be used as a dosimetric database to control mouse doses and preclinical targeted radiotherapy experiments. In addition, to accurately calculate the mouse-absorbed dose, the X-ray spectrum, detector alignment, and uncertainty in the elemental composition of the simulated materials must be accurately modeled.
Cook, Andrea M; Moritz, Andreas; Freeman, Kathleen P; Bauer, Natali
2016-09-01
Scarce information exists about quality requirements and objective evaluation of performance of large veterinary bench top hematology analyzers. The study was aimed at comparing the observed total error (TEobs ) derived from meta-analysis of published method validation data to the total allowable error (TEa ) for veterinary hematology variables in small animals based on experts' opinions. Ideally, TEobs should be < TEa . An online survey was sent to veterinary experts in clinical pathology and small animal internal medicine for providing the maximal allowable deviation from a given result for each variable. Percent of TEa = (allowable median deviation/clinical threshold) * 100%. Second, TEobs for 3 laser-based bench top hematology analyzers (ADVIA 2120; Sysmex XT2000iV, and CellDyn 3500) was calculated based on method validation studies published between 2005 and 2013 (n = 4). The percent TEobs = 2 * CV (%) + bias (%). The CV was derived from published studies except for the ADVIA 2120 (internal data), and bias was estimated from the regression equation. A total of 41 veterinary experts (19 diplomates, 8 residents, 10 postgraduate students, 4 anonymous specialists) responded. The proposed range of TEa was wide, but generally ≤ 20%. The TEobs was < TEa for all variables and analyzers except for canine and feline HGB (high bias, low CV) and platelet counts (high bias, high CV). Overall, veterinary bench top analyzers fulfilled experts' requirements except for HGB due to method-related bias, and platelet counts due to known preanalytic/analytic issues. © 2016 American Society for Veterinary Clinical Pathology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Waspe, Adam C.; McErlain, David D.; Pitelka, Vasek
Purpose: Preclinical research protocols often require insertion of needles to specific targets within small animal brains. To target biologically relevant locations in rodent brains more effectively, a robotic device has been developed that is capable of positioning a needle along oblique trajectories through a single burr hole in the skull under volumetric microcomputed tomography (micro-CT) guidance. Methods: An x-ray compatible stereotactic frame secures the head throughout the procedure using a bite bar, nose clamp, and ear bars. CT-to-robot registration enables structures identified in the image to be mapped to physical coordinates in the brain. Registration is accomplished by injecting amore » barium sulfate contrast agent as the robot withdraws the needle from predefined points in a phantom. Registration accuracy is affected by the robot-positioning error and is assessed by measuring the surface registration error for the fiducial and target needle tracks (FRE and TRE). This system was demonstrated in situ by injecting 200 {mu}m tungsten beads into rat brains along oblique trajectories through a single burr hole on the top of the skull under micro-CT image guidance. Postintervention micro-CT images of each skull were registered with preintervention high-field magnetic resonance images of the brain to infer the anatomical locations of the beads. Results: Registration using four fiducial needle tracks and one target track produced a FRE and a TRE of 96 and 210 {mu}m, respectively. Evaluation with tissue-mimicking gelatin phantoms showed that locations could be targeted with a mean error of 154{+-}113 {mu}m. Conclusions: The integration of a robotic needle-positioning device with volumetric micro-CT image guidance should increase the accuracy and reduce the invasiveness of stereotactic needle interventions in small animals.« less
Preclinical Evaluation of 18F-JNJ64349311, a Novel PET Tracer for Tau Imaging.
Declercq, Lieven; Rombouts, Frederik; Koole, Michel; Fierens, Katleen; Mariën, Jonas; Langlois, Xavier; Andrés, José Ignacio; Schmidt, Mark; Macdonald, Gregor; Moechars, Diederik; Vanduffel, Wim; Tousseyn, Thomas; Vandenberghe, Rik; Van Laere, Koen; Verbruggen, Alfons; Bormans, Guy
2017-06-01
In this study, we have synthesized and evaluated 18 F-JNJ64349311, a tracer with high affinity for aggregated tau (inhibition constant value, 8 nM) and high (≥500×) in vitro selectivity for tau over β-amyloid, in comparison with the benchmark compound 18 F-AV1451 ( 18 F-T807) in mice, rats, and a rhesus monkey. Methods: In vitro binding characteristics were determined for Alzheimer's disease, progressive supranuclear palsy, and corticobasal degeneration patient brain tissue slices using autoradiography studies. Ex vivo biodistribution studies were performed in mice. Radiometabolites were quantified in the brain and plasma of mice and in the plasma of a rhesus monkey using high-performance liquid chromatography. Dynamic small-animal PET studies were performed in rats and a rhesus monkey to evaluate tracer pharmacokinetics in the brain. Results: Mouse biodistribution studies showed moderate initial brain uptake and rapid brain washout. Radiometabolite analyses after injection of 18 F-JNJ64349311 in mice showed the presence of a polar radiometabolite in plasma, but not in the brain. Semiquantitative autoradiography studies on postmortem tissue sections of human Alzheimer's disease brains showed highly displaceable binding to tau-rich regions. No specific binding was, however, found on human progressive supranuclear palsy and corticobasal degeneration brain slices. Small-animal PET scans of Wistar rats revealed moderate initial brain uptake (SUV, ∼1.5 at 1 min after injection) and rapid brain washout. Gradual bone uptake was, however, also observed. Blocking and displacement did not affect brain time-activity curves, suggesting no off-target specific binding of the tracer in the healthy rat brain. A small-animal PET scan of a rhesus monkey revealed moderate initial brain uptake (SUV, 1.9 at 1 min after injection) with a rapid washout. In the monkey, no bone uptake was detected during the 120-min scan. Conclusion: This biologic evaluation suggests that 18 F-JNJ64349311 is a promising tau PET tracer candidate, with a favorable pharmacokinetic profile, as compared with 18 F-AV1451. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
Performance Evaluation of the microPET®—FOCUS-F120
NASA Astrophysics Data System (ADS)
Laforest, Richard; Longford, Desmond; Siegel, Stefan; Newport, Danny F.; Yap, Jeffrey
2007-02-01
microPETreg-Focus-F120 is the latest model of dedicated small animal PET scanners from CTI-Concorde Microsystems LLC, (Knoxville, TN). This scanner, based on the geometry of the microPET-R4, takes advantage of several detector modifications to the coincidence processing electronics that improve the image resolution, sensitivity, and counting rate performance as compared to the predecessor models. This work evaluates the performance of the Focus-F120 system and shows its improvement over the earlier models. In particular, the spatial resolution is shown to improve from 2.32 to 1.69 mm at 5 mm radial distance and the peak absolute sensitivity increases from 4.1% to 7.1% compared to the microPET-R4. The counting rate capability, expressed in noise equivalent counting rate (NEC-1R), was shown to peak at over 800 kcps at 88 MBq for both systems using a mouse phantom. For this small phantom, the NECR counting rate is limited by the data transmission bandwidth between the scanner and the acquisition console. The rat-like phantom showed peak NEC-1R value at 300 kcps at 140 MBq. Evaluation of image quality and quantitation accuracy was also performed using specially designed phantoms and animal experiments
NASA Astrophysics Data System (ADS)
Munn, Adam J.; Kern, Pippa; McAllan, Bronwyn M.
2010-06-01
The severity, duration and amplitude of extreme weather events are forecast to intensify with current climate trends, over both long (e.g. seasonal) and short (e.g. daily) time-scales. As such, the predictability of food supplies for many small endotherms is likely to become increasingly important. Numerous small mammals and birds combat food shortages using torpor, a controlled reduction in metabolic rate and body temperature that helps lower their daily energy requirements. As such, torpor often has been cited as a key feature allowing some small endotherms to survive highly unpredictable climates, such as tropics or dry deserts, but mensurative demonstrations of this are lacking. We have shown here that when a small desert marsupial, the fat-tailed dunnart ( Sminthopsis crassicaudata), is offered unpredictable levels of daily food, they increase frequency of daily torpor and length of bouts compared with animals offered ad libitum food, but this was not found for animals offered a 70% food-restricted diet. Our data suggest that simple food restriction may not be sufficient for evaluating the efficacy of torpor as a strategy for managing unpredictable climates.
De Lin, Ming; Toncheva, Greta; Nguyen, Giao; Kim, Sangroh; Anderson-Evans, Colin; Johnson, G Allan; Yoshizumi, Terry T
2008-08-01
Digital subtraction angiography (DSA) X-ray imaging for small animals can be used for functional phenotyping given its ability to capture rapid physiological changes at high spatial and temporal resolution. The higher temporal and spatial requirements for small-animal imaging drive the need for short, high-flux X-ray pulses. However, high doses of ionizing radiation can affect the physiology. The purpose of this study was to verify and apply metal oxide semiconductor field effect transistor (MOSFET) technology to dosimetry for small-animal diagnostic imaging. A tungsten anode X-ray source was used to expose a tissue-equivalent mouse phantom. Dose measurements were made on the phantom surface and interior. The MOSFETs were verified with thermoluminescence dosimeters (TLDs). Bland-Altman analysis showed that the MOSFET results agreed with the TLD results (bias, 0.0625). Using typical small animal DSA scan parameters, the dose ranged from 0.7 to 2.2 cGy. Application of the MOSFETs in the small animal environment provided two main benefits: (1) the availability of results in near real-time instead of the hours needed for TLD processes and (2) the ability to support multiple exposures with different X-ray techniques (various of kVp, mA and ms) using the same MOSFET. This MOSFET technology has proven to be a fast, reliable small animal dosimetry method for DSA imaging and is a good system for dose monitoring for serial and gene expression studies.
Application of MOSFET Detectors for Dosimetry in Small Animal Radiography Using Short Exposure Times
De Lin, Ming; Toncheva, Greta; Nguyen, Giao; Kim, Sangroh; Anderson-Evans, Colin; Johnson, G. Allan; Yoshizumi, Terry T.
2008-01-01
Digital subtraction angiography (DSA) X-ray imaging for small animals can be used for functional phenotyping given its ability to capture rapid physiological changes at high spatial and temporal resolution. The higher temporal and spatial requirements for small-animal imaging drive the need for short, high-flux X-ray pulses. However, high doses of ionizing radiation can affect the physiology. The purpose of this study was to verify and apply metal oxide semiconductor field effect transistor (MOSFET) technology to dosimetry for small-animal diagnostic imaging. A tungsten anode X-ray source was used to expose a tissue-equivalent mouse phantom. Dose measurements were made on the phantom surface and interior. The MOSFETs were verified with thermoluminescence dosimeters (TLDs). Bland-Altman analysis showed that the MOSFET results agreed with the TLD results (bias, 0.0625). Using typical small animal DSA scan parameters, the dose ranged from 0.7 to 2.2 cGy. Application of the MOSFETs in the small animal environment provided two main benefits: (1) the availability of results in near real-time instead of the hours needed for TLD processes and (2) the ability to support multiple exposures with different X-ray techniques (various of kVp, mA and ms) using the same MOSFET. This MOSFET technology has proven to be a fast, reliable small animal dosimetry method for DSA imaging and is a good system for dose monitoring for serial and gene expression studies. PMID:18666818
Huang, Chi-Cheng; Wu, Chun-Hu; Huang, Ya-Yao; Tzen, Kai-Yuan; Chen, Szu-Fu; Tsai, Miao-Ling; Wu, Hsiao-Ming
2017-04-01
Performing quantitative small-animal PET with an arterial input function has been considered technically challenging. Here, we introduce a catheterization procedure that keeps a rat physiologically stable for 1.5 mo. We demonstrated the feasibility of quantitative small-animal 18 F-FDG PET in rats by performing it repeatedly to monitor the time course of variations in the cerebral metabolic rate of glucose (CMR glc ). Methods: Aseptic surgery was performed on 2 rats. Each rat underwent catheterization of the right femoral artery and left femoral vein. The catheters were sealed with microinjection ports and then implanted subcutaneously. Over the next 3 wk, each rat underwent 18 F-FDG quantitative small-animal PET 6 times. The CMR glc of each brain region was calculated using a 3-compartment model and an operational equation that included a k* 4 Results: On 6 mornings, we completed 12 18 F-FDG quantitative small-animal PET studies on 2 rats. The rats grew steadily before and after the 6 quantitative small-animal PET studies. The CMR glc of the conscious brain (e.g., right parietal region, 99.6 ± 10.2 μmol/100 g/min; n = 6) was comparable to that for 14 C-deoxyglucose autoradiographic methods. Conclusion: Maintaining good blood patency in catheterized rats is not difficult. Longitudinal quantitative small-animal PET imaging with an arterial input function can be performed routinely. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
Phillips, Brianne E; Venn-Watson, Stephanie; Archer, Linda L; Nollens, Hendrik H; Wellehan, James F X
2014-10-01
Hemochromatosis (iron storage disease) has been reported in diverse mammals including bottlenose dolphins (Tursiops truncatus). The primary cause of excessive iron storage in humans is hereditary hemochromatosis. Most human hereditary hemochromatosis cases (up to 90%) are caused by a point mutation in the hfe gene, resulting in a C282Y substitution leading to iron accumulation. To evaluate the possibility of a hereditary hemochromatosis-like genetic predisposition in dolphins, we sequenced the bottlenose dolphin hfe gene, using reverse transcriptase-PCR and hfe primers designed from the dolphin genome, from liver of affected and healthy control dolphins. Sample size included two case animals and five control animals. Although isotype diversity was evident, no coding differences were identified in the hfe gene between any of the animals examined. Because our sample size was small, we cannot exclude the possibility that hemochromatosis in dolphins is due to a coding mutation in the hfe gene. Other potential causes of hemochromatosis, including mutations in different genes, diet, primary liver disease, and insulin resistance, should be evaluated.
Many regions in the United States have excessive levels of ammonia in their drinking water sources (e.g., ground and surface waters) as a result of naturally occurring processes, agricultural and urban runoff, concentrated animal feeding operations, municipal wastewater treatment...
Visual implant elastomer mark retention through metamorphosis in amphibian larvae
Campbell Grant, Evan H.
2008-01-01
Questions in population ecology require the study of marked animals, and marks are assumed to be permanent and not overlooked by observers. I evaluated retention through metamorphosis of visual implant elastomer marks in larval salamanders and frogs and assessed error in observer identification of these marks. I found 1) individual marks were not retained in larval wood frogs (Rana sylvatica), whereas only small marks were likely to be retained in larval salamanders (Eurycea bislineata), and 2) observers did not always correctly identify marked animals. Evaluating the assumptions of marking protocols is important in the design phase of a study so that correct inference can be made about the population processes of interest. This guidance should be generally useful to the design of mark–recapture studies, with particular application to studies of larval amphibians.
Assessing Glomerular Filtration in Small Animals Using [68Ga]DTPA and [68Ga]EDTA with PET Imaging.
Gündel, Daniel; Pohle, Ulrike; Prell, Erik; Odparlik, Andreas; Thews, Oliver
2018-06-01
Determining the glomerular filtration rate (GFR) is essential for clinical medicine but also for pre-clinical animal studies. Functional imaging using positron emission tomography (PET) allows repetitive almost non-invasive measurements. The aim of the study was the development and evaluation of easily synthesizable PET tracers for GFR measurements in small animals. Diethylenetriaminepentaacetic acid (DTPA) and ethylenediaminetetraacetic acid (EDTA) were labeled with Ga-68. The binding to blood cells and plasma proteins was tested in vitro. The distribution of the tracers in rats was analyzed by PET imaging and ex vivo measurements. From the time-activity-curve of the blood compartment (heart) and the total tracer mass excreted by the kidney, the GFR was calculated. These values were compared directly with the inulin clearance in the same animals. Both tracers did not bind to blood cells. [ 68 Ga]DPTA but not [ 68 Ga]EDTA showed strong binding to plasma proteins. For this reason, [ 68 Ga]DPTA stayed much longer in the blood and only 30 % of the injected dose was eliminated by the kidney within 60 min whereas the excretion of [ 68 Ga]EDTA was 89 ± 1 %. The calculated GFR using [ 68 Ga]EDTA was comparable to the measured inulin clearance in the same animal. Using [ 68 Ga]-DPTA, the measurements led to values which were 80 % below the normal GFR. The results also revealed that definition of the volume of interest for the blood compartment affects the calculation and may lead to a slight overestimation of the GFR. [ 68 Ga]EDTA is a suitable tracer for GFR calculation from PET imaging in small animals. It is easy to be labeled, and the results are in good accordance with the inulin clearance. [ 68 Ga]DTPA led to a marked underestimation of GFR due to its strong binding to plasma proteins and is therefore not an appropriate tracer for GFR measurements.
Perspective: Dendrimer drugs for infection and inflammation.
Shaunak, Sunil
2015-12-18
Biologists are dissecting complex biological pathways at breath taking speed. It is opening up new opportunities for the therapeutic evaluation of novel dendrimer drugs. This review focuses on studies of small dendrimers decorated with sulfate, phosphonate, N-acetyl-cysteine, glucosamine and mannose in animal model studies of infection and inflammation. It highlights those animal model studies which have demonstrated the most promising dendrimer drug constructs as potential new medicines. The issues relating to their analytical chemistry that are slowing the progress of dendrimer drugs into the clinic are highlighted. It should be possible to solve these with additional analytical expertise because it is small dendrimers with only 16-32 peripheral groups that make for the best infection and inflammation related medicines. Public-private partnerships are now needed to progress these dendrimer drugs into proof-of-concept clinical trials. Copyright © 2015 Elsevier Inc. All rights reserved.
System Performance Simulations of the RatCAP Awake Rat Brain Scanner
NASA Astrophysics Data System (ADS)
Shokouhi, S.; Vaska, P.; Schlyer, D. J.; Stoll, S. P.; Villanueva, A.; Kriplani, A.; Woody, C. L.
2005-10-01
The capability to create high quality images from data acquired by the Rat Conscious Animal PET tomograph (RatCAP) has been evaluated using modified versions of the PET Monte Carlo code Simulation System for Emission Tomography (SimSET). The proposed tomograph consists of lutetium oxyorthosilicate (LSO) crystals arranged in 12 4 /spl times/ 8 blocks. The effects of the RatCAPs small ring diameter (/spl sim/40 mm) and its block detector geometry on image quality for small animal studies have been investigated. Since the field of view will be almost as large as the ring diameter, radial elongation artifacts due to parallax error are expected to degrade the spatial resolution and thus the image quality at the edge of the field of view. In addition to Monte Carlo simulations, some preliminary results of experimentally acquired images in both two-dimensional (2-D) and 3-D modes are presented.
NASA Astrophysics Data System (ADS)
Liu, Junting; Tian, Jie; Liang, Jimin; Li, Xiangsi; Yang, Xiang; Chen, Xiaofeng; Chen, Yi; Zhou, Yuanfang; Wang, Xiaorui
2011-03-01
Immunocytochemical and immunofluorescence staining are used for identifying the characteristics of metastasis in traditional ways. Micro-computed tomography (micro-CT) is a useful tool for monitoring and longitudinal imaging of tumor in small animal in vivo. In present study, we evaluated the feasibility of the detection for metastasis of gastric carcinoma by high-resolution micro-CT system with omnipaque accumulative enhancement method in the organs. Firstly, a high-resolution micro-CT ZKKS-MCT-sharp micro-CT was developed by our research group and Guangzhou Zhongke Kaisheng Medical Technology Co., Ltd. Secondly, several gastric carcinoma models were established through inoculating 2x106 BGC-823 gastric carcinoma cells subcutaneously. Thirdly, micro-CT scanning was performed after accumulative enhancement method of intraperitoneal injection of omnipaque contrast agent containing 360 mg iodine with a concentration of 350 mg I/ml. Finally, we obtained high-resolution anatomical information of the metastasis in vivo in a BALB/c NuNu nude mouse, the 3D tumor architecture is revealed in exquisite detail at about 35 μm spatial resolution. In addition, the accurate shape and volume of the micrometastasis as small as 0.78 mm3 can be calculated with our software. Overall, our data suggest that this imaging approach and system could be used to enhance the understanding of tumor proliferation, metastasis and could be the basis for evaluating anti-tumor therapies.
An improved camera trap for amphibians, reptiles, small mammals, and large invertebrates
Hobbs, Michael T.; Brehme, Cheryl S.
2017-01-01
Camera traps are valuable sampling tools commonly used to inventory and monitor wildlife communities but are challenged to reliably sample small animals. We introduce a novel active camera trap system enabling the reliable and efficient use of wildlife cameras for sampling small animals, particularly reptiles, amphibians, small mammals and large invertebrates. It surpasses the detection ability of commonly used passive infrared (PIR) cameras for this application and eliminates problems such as high rates of false triggers and high variability in detection rates among cameras and study locations. Our system, which employs a HALT trigger, is capable of coupling to digital PIR cameras and is designed for detecting small animals traversing small tunnels, narrow trails, small clearings and along walls or drift fencing.
An improved camera trap for amphibians, reptiles, small mammals, and large invertebrates.
Hobbs, Michael T; Brehme, Cheryl S
2017-01-01
Camera traps are valuable sampling tools commonly used to inventory and monitor wildlife communities but are challenged to reliably sample small animals. We introduce a novel active camera trap system enabling the reliable and efficient use of wildlife cameras for sampling small animals, particularly reptiles, amphibians, small mammals and large invertebrates. It surpasses the detection ability of commonly used passive infrared (PIR) cameras for this application and eliminates problems such as high rates of false triggers and high variability in detection rates among cameras and study locations. Our system, which employs a HALT trigger, is capable of coupling to digital PIR cameras and is designed for detecting small animals traversing small tunnels, narrow trails, small clearings and along walls or drift fencing.
Experimental root canal infections in conventional and germ-free mice.
Sobrinho, A P; Barros, M H; Nicoli, J R; Carvalho, M A; Farias, L M; Bambirra, E A; Bahia, M G; Vieira, E C
1998-06-01
A small animal model was evaluated to study the interrelationships between microorganisms after their implantation in root canals (inferior central incisors) using germ-free (GF) and conventional (CV) mice. The selected microorganisms were: Porphyromonas endodontalis (ATCC 35406), Eubacterium lentum (ATCC 25559), Peptostreptococcus anaerobius (ATCC 27337), Fusobacterium nucleatum (ATCC 10953), Escherichia coli (ATCC 25922), and Enterococcus faecalis (ATCC 4083). Only P. anaerobius, E. coli, and E. faecalis, respectively, were able to colonize when inoculated alone into the root canal of both CV and GF mice. E. lentum, when inoculated alone colonized only in CV animals. P. endodontalis and F. nucleatum were unable to colonize in CV and GF animals after single inoculation. It is concluded that the experimental animal model presented herein is valuable for ecological studies of root canal infections and that only some strict anaerobic bacteria are able to colonize mice root canals when inoculated by themselves alone in pure culture.
Severns, Paul M.
2015-01-01
Consumer-grade GPS units are a staple of modern field ecology, but the relatively large error radii reported by manufacturers (up to 10 m) ostensibly precludes their utility in measuring fine-scale movement of small animals such as insects. Here we demonstrate that for data collected at fine spatio-temporal scales, these devices can produce exceptionally accurate data on step-length and movement patterns of small animals. With an understanding of the properties of GPS error and how it arises, it is possible, using a simple field protocol, to use consumer grade GPS units to collect step-length data for the movement of small animals that introduces a median error as small as 11 cm. These small error rates were measured in controlled observations of real butterfly movement. Similar conclusions were reached using a ground-truth test track prepared with a field tape and compass and subsequently measured 20 times using the same methodology as the butterfly tracking. Median error in the ground-truth track was slightly higher than the field data, mostly between 20 and 30 cm, but even for the smallest ground-truth step (70 cm), this is still a signal-to-noise ratio of 3:1, and for steps of 3 m or more, the ratio is greater than 10:1. Such small errors relative to the movements being measured make these inexpensive units useful for measuring insect and other small animal movements on small to intermediate scales with budgets orders of magnitude lower than survey-grade units used in past studies. As an additional advantage, these units are simpler to operate, and insect or other small animal trackways can be collected more quickly than either survey-grade units or more traditional ruler/gird approaches. PMID:26312190
Breed, Greg A; Severns, Paul M
2015-01-01
Consumer-grade GPS units are a staple of modern field ecology, but the relatively large error radii reported by manufacturers (up to 10 m) ostensibly precludes their utility in measuring fine-scale movement of small animals such as insects. Here we demonstrate that for data collected at fine spatio-temporal scales, these devices can produce exceptionally accurate data on step-length and movement patterns of small animals. With an understanding of the properties of GPS error and how it arises, it is possible, using a simple field protocol, to use consumer grade GPS units to collect step-length data for the movement of small animals that introduces a median error as small as 11 cm. These small error rates were measured in controlled observations of real butterfly movement. Similar conclusions were reached using a ground-truth test track prepared with a field tape and compass and subsequently measured 20 times using the same methodology as the butterfly tracking. Median error in the ground-truth track was slightly higher than the field data, mostly between 20 and 30 cm, but even for the smallest ground-truth step (70 cm), this is still a signal-to-noise ratio of 3:1, and for steps of 3 m or more, the ratio is greater than 10:1. Such small errors relative to the movements being measured make these inexpensive units useful for measuring insect and other small animal movements on small to intermediate scales with budgets orders of magnitude lower than survey-grade units used in past studies. As an additional advantage, these units are simpler to operate, and insect or other small animal trackways can be collected more quickly than either survey-grade units or more traditional ruler/gird approaches.
Development and dosimetry of a small animal lung irradiation platform
McGurk, Ross; Hadley, Caroline; Jackson, Isabel L.; Vujaskovic, Zeljko
2015-01-01
Advances in large scale screening of medical counter measures for radiation-induced normal tissue toxicity are currently hampered by animal irradiation paradigms that are both inefficient and highly variable among institutions. Here, we introduce a novel high-throughput small animal irradiation platform for use in orthovoltage small animal irradiators. We used radiochromic film and metal oxide semiconductor field effect transistor detectors to examine several parameters, including 2D field uniformity, dose rate consistency, and shielding transmission. We posit that this setup will improve efficiency of drug screens by allowing for simultaneous, targeted irradiation of multiple animals, improving efficiency within a single institution. Additionally, we suggest that measurement of the described parameters in all centers conducting counter measure studies will improve the translatability of findings among institutions. We also investigated the use of tissue equivalent phantoms in performing dosimetry measurements for small animal irradiation experiments. Though these phantoms are commonly used in dosimetry, we recorded a significant difference in both the entrance and target tissue dose rates between euthanized rats and mice with implanted detectors and the corresponding phantom measurement. This suggests that measurements using these phantoms may not provide accurate dosimetry for in vivo experiments. Based on these measurements, we propose that this small animal irradiation platform can increase the capacity of animal studies by allowing for more efficient animal irradiation. We also suggest that researchers fully characterize the parameters of whatever radiation setup is in use in order to facilitate better comparison among institutions. PMID:23091878
Audiovisual Presentations on a Handheld PC are Preferred As an Educational Tool by NICU Parents.
Alur, P; Cirelli, J; Goodstein, M; Bell, T; Liss, J
2010-01-01
Health literacy is critical for understanding complex medical problems and necessary for the well being of the patient. Printed educational materials (PM) have limitations in explaining the dynamics of a disease process. Multimedia formats may be useful for enhancing the educational process. To evaluate whether a printed format or animation with commentary on a handheld personal computer (PC) is preferred as an educational tool by parents of a baby in the NICU. PARENTS EVALUATED TWO FORMATS: A 1-page illustrated document from the American Heart Association explaining patent ductus arteriosus (PDA) and animation with commentary on a handheld PC that explained the physiology of PDA in 1 minute. The reading grade level of the PM was 8.6 versus 18.6 for the audio portion of the animated presentation. Parents viewed each format and completed a four-item questionnaire. Parents rated both formats and indicated their preference as printed, animation, or both. Forty-six parents participated in the survey. Parents preferred animation over PM (50% vs. 17.4%. p = 0.02); 39.1% expressed that the animation was excellent; whereas 4.3% expressed that the PM was excellent (p<0.001). The order of presentation of formats, sex, age, and educational level of parents did not influence the method preferred (p>0.05). Parents preferred animation on a small screen handheld PC despite a much higher language level. Because handheld PCs are portable and inexpensive, they can be used effectively at the bedside with low-cost animation to enhance understanding of complex disease conditions.
Audiovisual Presentations on a Handheld PC are Preferred As an Educational Tool by NICU Parents
Alur, P.; Cirelli, J.; Goodstein, M.; Bell, T.; Liss, J.
2010-01-01
Background Health literacy is critical for understanding complex medical problems and necessary for the well being of the patient. Printed educational materials (PM) have limitations in explaining the dynamics of a disease process. Multimedia formats may be useful for enhancing the educational process. Objective To evaluate whether a printed format or animation with commentary on a handheld personal computer (PC) is preferred as an educational tool by parents of a baby in the NICU. Methods Parents evaluated two formats: A 1-page illustrated document from the American Heart Association explaining patent ductus arteriosus (PDA) and animation with commentary on a handheld PC that explained the physiology of PDA in 1 minute. The reading grade level of the PM was 8.6 versus 18.6 for the audio portion of the animated presentation. Parents viewed each format and completed a four-item questionnaire. Parents rated both formats and indicated their preference as printed, animation, or both. Results Forty-six parents participated in the survey. Parents preferred animation over PM (50% vs. 17.4%. p = 0.02); 39.1% expressed that the animation was excellent; whereas 4.3% expressed that the PM was excellent (p<0.001). The order of presentation of formats, sex, age, and educational level of parents did not influence the method preferred (p>0.05). Conclusion Parents preferred animation on a small screen handheld PC despite a much higher language level. Because handheld PCs are portable and inexpensive, they can be used effectively at the bedside with low-cost animation to enhance understanding of complex disease conditions. PMID:23616833
Butovich, Igor A.; Lu, Hua; McMahon, Anne; Eule, J. Corinna
2012-01-01
Purpose. Secretions that are produced by meibomian glands (also known as meibum) are a major source of lipids for the ocular surface of humans and animals alike. Many animal species have been evaluated for their meibomian lipidomes. However, there have been a very small number of studies in which the animals were compared with humans side by side. Therefore, the purpose of this study was to compare meibum collected from humans and three typical laboratory animals, canines, mice, and rabbits, for their meibomian lipid composition in order to determine which animal species most resembles humans. Methods. High pressure liquid chromatography (HPLC) and gas-liquid chromatography (GLC) in combination with mass spectrometry were used to evaluate lipidomes of all tested species. Results. Among three tested animal species, mice were found to be the closest match to humans in terms of their meibomian lipidomes, while canines were the second closest species. The lipids of these three species were close to each other structurally and, for most lipid classes, quantitatively. The rabbit meibomian lipidome, on the other hand, was vastly different from lipidomes of all other tested species. Interestingly, a previously described class of lipids, acylated omega-hydroxy fatty acids (OAHFA), was found to be present in every tested species as the major amphiphilic component of meibum. Conclusions. Our side by side comparison of the rabbit and the human meibum demonstrated their vast differences. Thus, the rabbit seems to be a poor animal model of the human tear film, at least when studying its biochemistry and biophysics. PMID:22918629
Advanced Small Animal Conformal Radiation Therapy Device.
Sharma, Sunil; Narayanasamy, Ganesh; Przybyla, Beata; Webber, Jessica; Boerma, Marjan; Clarkson, Richard; Moros, Eduardo G; Corry, Peter M; Griffin, Robert J
2017-02-01
We have developed a small animal conformal radiation therapy device that provides a degree of geometrical/anatomical targeting comparable to what is achievable in a commercial animal irradiator. small animal conformal radiation therapy device is capable of producing precise and accurate conformal delivery of radiation to target as well as for imaging small animals. The small animal conformal radiation therapy device uses an X-ray tube, a robotic animal position system, and a digital imager. The system is in a steel enclosure with adequate lead shielding following National Council on Radiation Protection and Measurements 49 guidelines and verified with Geiger-Mueller survey meter. The X-ray source is calibrated following AAPM TG-61 specifications and mounted at 101.6 cm from the floor, which is a primary barrier. The X-ray tube is mounted on a custom-made "gantry" and has a special collimating assembly system that allows field size between 0.5 mm and 20 cm at isocenter. Three-dimensional imaging can be performed to aid target localization using the same X-ray source at custom settings and an in-house reconstruction software. The small animal conformal radiation therapy device thus provides an excellent integrated system to promote translational research in radiation oncology in an academic laboratory. The purpose of this article is to review shielding and dosimetric measurement and highlight a few successful studies that have been performed to date with our system. In addition, an example of new data from an in vivo rat model of breast cancer is presented in which spatially fractionated radiation alone and in combination with thermal ablation was applied and the therapeutic benefit examined.
Allen, Samantha E; Boerlin, Patrick; Janecko, Nicol; Lumsden, John S; Barker, Ian K; Pearl, David L; Reid-Smith, Richard J; Jardine, Claire
2011-02-01
To assess the impacts of different types of human activity on the development of resistant bacteria in the feces of wild small mammals, we compared the prevalences and patterns of antimicrobial resistance and resistance genes in generic Escherichia coli and Salmonella enterica isolates from fecal samples collected from wild small mammals living in four environments: swine farms, residential areas, landfills, and natural habitats. Resistance to antimicrobials was observed in E. coli isolates from animals in all environments: 25/52 (48%) animals trapped at swine farms, 6/69 (9%) animals trapped in residential areas, 3/20 (15%) animals trapped at landfills, and 1/22 (5%) animals trapped in natural habitats. Animals trapped on farms were significantly more likely to carry E. coli isolates with resistance to tetracycline, ampicillin, sulfisoxazole, and streptomycin than animals trapped in residential areas. The resistance genes sul2, aadA, and tet(A) were significantly more likely to be detected in E. coli isolates from animals trapped on farms than from those trapped in residential areas. Three S. enterica serotypes (Give, Typhimurium, and Newport) were recovered from the feces of 4/302 (1%) wild small mammals. All Salmonella isolates were pansusceptible. Our results show that swine farm origin is significantly associated with the presence of resistant bacteria and resistance genes in wild small mammals in southern Ontario, Canada. However, resistant fecal bacteria were found in small mammals living in all environments studied, indicating that environmental exposure to antimicrobials, antimicrobial residues, resistant bacteria, or resistance genes is widespread.
Real-time phase-contrast x-ray imaging: a new technique for the study of animal form and function
Socha, John J; Westneat, Mark W; Harrison, Jon F; Waters, James S; Lee, Wah-Keat
2007-01-01
Background Despite advances in imaging techniques, real-time visualization of the structure and dynamics of tissues and organs inside small living animals has remained elusive. Recently, we have been using synchrotron x-rays to visualize the internal anatomy of millimeter-sized opaque, living animals. This technique takes advantage of partially-coherent x-rays and diffraction to enable clear visualization of internal soft tissue not viewable via conventional absorption radiography. However, because higher quality images require greater x-ray fluxes, there exists an inherent tradeoff between image quality and tissue damage. Results We evaluated the tradeoff between image quality and harm to the animal by determining the impact of targeted synchrotron x-rays on insect physiology, behavior and survival. Using 25 keV x-rays at a flux density of 80 μW/mm-2, high quality video-rate images can be obtained without major detrimental effects on the insects for multiple minutes, a duration sufficient for many physiological studies. At this setting, insects do not heat up. Additionally, we demonstrate the range of uses of synchrotron phase-contrast imaging by showing high-resolution images of internal anatomy and observations of labeled food movement during ingestion and digestion. Conclusion Synchrotron x-ray phase contrast imaging has the potential to revolutionize the study of physiology and internal biomechanics in small animals. This is the only generally applicable technique that has the necessary spatial and temporal resolutions, penetrating power, and sensitivity to soft tissue that is required to visualize the internal physiology of living animals on the scale from millimeters to microns. PMID:17331247
Camps-Bossacoma, Mariona; Pérez-Cano, Francisco J; Franch, Àngels; Untersmayr, Eva; Castell, Margarida
2017-04-01
Previous studies have attributed to the cocoa powder the capacity to attenuate the immune response in a rat oral sensitization model. To gain a better understanding of cocoa-induced mechanisms at small intestinal level, 3-week-old female Lewis rats were fed either a standard diet or a diet containing 10% cocoa for 4 weeks with or without concomitant oral sensitization with ovalbumin (OVA). Thereafter, we evaluated the lymphocyte composition of the Peyer's patches (PPL), small intestine epithelium (IEL) and lamina propria (LPL). Likewise, gene expression of several immune molecules was quantified in the small intestine. Moreover, histological samples were used to evaluate the proportion of goblet cells, IgA+ cells and granzyme+cells as well. In cocoa-fed animals, we identified a five-time reduction in the percentage of IgA+ cells in intestinal tissue together with a decreased proportion of TLR4+ IEL. Analyzing the lymphocyte composition, almost a double proportion of TCRγδ+cells and an increase of NK cell percentage in PPL and IEL were found. In addition, a rise in CD25+, CD103+ and CD62L- cell proportions was observed in CD4+ PPL from cocoa-fed animals, along with a decrease in gene expression of CD11b, CD11c and IL-10. These results suggest that changes in PPL and IEL composition and in the gene expression induced by the cocoa diet could be involved, among other mechanisms, on its tolerogenic effect. Copyright © 2017 Elsevier Inc. All rights reserved.
Camps-Bossacoma, Mariona; Pérez-Cano, Francisco J.; Franch, Àngels; Untersmayr, Eva; Castell, Margarida
2018-01-01
Previous studies have attributed to the cocoa powder the capacity to attenuate the immune response in a rat oral sensitization model. To gain a better understanding of cocoa-induced mechanisms at small intestinal level, 3-week-old female Lewis rats were fed either a standard diet or a diet containing 10% cocoa for 4 weeks with or without concomitant oral sensitization with ovalbumin (OVA). Thereafter, we evaluated the lymphocyte composition of the Peyer’s patches (PPL), small intestine epithelium (IEL) and lamina propria (LPL). Likewise, gene expression of several immune molecules was quantified in the small intestine. Moreover, histological samples were used to evaluate the proportion of goblet cells, IgA+ cells and granzyme+ cells as well. In cocoa-fed animals, we identified a five time reduction in the percentage of IgA+ cells in intestinal tissue together with a decreased proportion of TLR4+ IEL. Analyzing the lymphocyte composition, almost a double proportion of TCRγδ+ cells and an increase of NK cell percentage in PPL and IEL were found. In addition, a rise in CD25+, CD103+ and CD62L- cell proportions was observed in CD4+ PPL from cocoa-fed animals, along with a decrease in gene expression of CD11b, CD11c and IL-10. These results suggest that changes in PPL and IEL composition and in the gene expression induced by the cocoa diet could be involved, among other mechanisms, on its tolerogenic effect. PMID:28189917
Casteels, Cindy; Vunckx, Kathleen; Aelvoet, Sarah-Ann; Baekelandt, Veerle; Bormans, Guy; Van Laere, Koen; Koole, Michel
2013-01-01
Automated voxel-based or pre-defined volume-of-interest (VOI) analysis of small-animal PET data in mice is necessary for optimal information usage as the number of available resolution elements is limited. We have mapped metabolic ([(18)F]FDG) and dopamine transporter ([(18)F]FECT) small-animal PET data onto a 3D Magnetic Resonance Microscopy (MRM) mouse brain template and aligned them in space to the Paxinos co-ordinate system. In this way, ligand-specific templates for sensitive analysis and accurate anatomical localization were created. Next, using a pre-defined VOI approach, test-retest and intersubject variability of various quantification methods were evaluated. Also, the feasibility of mouse brain statistical parametric mapping (SPM) was explored for [(18)F]FDG and [(18)F]FECT imaging of 6-hydroxydopamine-lesioned (6-OHDA) mice. Twenty-three adult C57BL6 mice were scanned with [(18)F]FDG and [(18)F]FECT. Registrations and affine spatial normalizations were performed using SPM8. [(18)F]FDG data were quantified using (1) an image-derived-input function obtained from the liver (cMRglc), using (2) standardized uptake values (SUVglc) corrected for blood glucose levels and by (3) normalizing counts to the whole-brain uptake. Parametric [(18)F]FECT binding images were constructed by reference to the cerebellum. Registration accuracy was determined using random simulated misalignments and vectorial mismatch determination. Registration accuracy was between 0.21-1.11 mm. Regional intersubject variabilities of cMRglc ranged from 15.4% to 19.2%, while test-retest values were between 5.0% and 13.0%. For [(18)F]FECT uptake in the caudate-putamen, these values were 13.0% and 10.3%, respectively. Regional values of cMRglc positively correlated to SUVglc measured within the 45-60 min time frame (spearman r = 0.71). Next, SPM analysis of 6-OHDA-lesioned mice showed hypometabolism in the bilateral caudate-putamen and cerebellum, and an unilateral striatal decrease in DAT availability. MRM-based small-animal PET templates facilitate accurate assessment and spatial localization of mouse brain function using VOI or voxel-based analysis. Regional intersubject- and test-retest variations indicate that for these targets accuracy comparable to humans can be achieved.
Animals In Synchrotrons: Overcoming Challenges For High-Resolution, Live, Small-Animal Imaging
NASA Astrophysics Data System (ADS)
Donnelley, Martin; Parsons, David; Morgan, Kaye; Siu, Karen
2010-07-01
Physiological studies in small animals can be complicated, but the complexity is increased dramatically when performing live-animal synchrotron X-ray imaging studies. Our group has extensive experience in high-resolution live-animal imaging at the Japanese SPring-8 synchrotron, primarily examining airways in two-dimensions. These experiments normally image an area of 1.8 mm×1.2 mm at a pixel resolution of 0.45 μm and are performed with live, intact, anaesthetized mice. There are unique challenges in this experimental setting. Importantly, experiments must be performed in an isolated imaging hutch not specifically designed for small-animal imaging. This requires equipment adapted to remotely monitor animals, maintain their anesthesia, and deliver test substances while collecting images. The horizontal synchrotron X-ray beam has a fixed location and orientation that limits experimental flexibility. The extremely high resolution makes locating anatomical regions-of-interest slow and can result in a high radiation dose, and at this level of magnification small animal movements produce motion-artifacts that can render acquired images unusable. Here we describe our experimental techniques and how we have overcome several challenges involved in performing live mouse synchrotron imaging. Experiments have tested different mouse strains, with hairless strains minimizing overlying skin and hair artifacts. Different anesthetics have also be trialed due to the limited choices available at SPring-8. Tracheal-intubation methods have been refined and controlled-ventilation is now possible using a specialized small-animal ventilator. With appropriate animal restraint and respiratory-gating, motion-artifacts have been minimized. The animal orientation (supine vs. head-high) also appears to affect animal physiology, and can alter image quality. Our techniques and image quality at SPring-8 have dramatically improved and in the near future we plan to translate this experience to the Imaging and Medical Beamline at the Australian Synchrotron. Overcoming these challenges has permitted increasingly sophisticated imaging of animals with synchrotron X-rays, and we expect a bright future for these techniques.
Animals In Synchrotrons: Overcoming Challenges For High-Resolution, Live, Small-Animal Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Donnelley, Martin; Parsons, David; Women's and Children's Health Research Institute, Adelaide, South Australia
Physiological studies in small animals can be complicated, but the complexity is increased dramatically when performing live-animal synchrotron X-ray imaging studies. Our group has extensive experience in high-resolution live-animal imaging at the Japanese SPring-8 synchrotron, primarily examining airways in two-dimensions. These experiments normally image an area of 1.8 mmx1.2 mm at a pixel resolution of 0.45 {mu}m and are performed with live, intact, anaesthetized mice.There are unique challenges in this experimental setting. Importantly, experiments must be performed in an isolated imaging hutch not specifically designed for small-animal imaging. This requires equipment adapted to remotely monitor animals, maintain their anesthesia, andmore » deliver test substances while collecting images. The horizontal synchrotron X-ray beam has a fixed location and orientation that limits experimental flexibility. The extremely high resolution makes locating anatomical regions-of-interest slow and can result in a high radiation dose, and at this level of magnification small animal movements produce motion-artifacts that can render acquired images unusable. Here we describe our experimental techniques and how we have overcome several challenges involved in performing live mouse synchrotron imaging.Experiments have tested different mouse strains, with hairless strains minimizing overlying skin and hair artifacts. Different anesthetics have also be trialed due to the limited choices available at SPring-8. Tracheal-intubation methods have been refined and controlled-ventilation is now possible using a specialized small-animal ventilator. With appropriate animal restraint and respiratory-gating, motion-artifacts have been minimized. The animal orientation (supine vs. head-high) also appears to affect animal physiology, and can alter image quality. Our techniques and image quality at SPring-8 have dramatically improved and in the near future we plan to translate this experience to the Imaging and Medical Beamline at the Australian Synchrotron.Overcoming these challenges has permitted increasingly sophisticated imaging of animals with synchrotron X-rays, and we expect a bright future for these techniques.« less
The impact of wild birds and farm management on Campylobacter and Salmonella in small ruminants
USDA-ARS?s Scientific Manuscript database
This study was designed to evaluate the potential pathways and control of foodborne pathogen transmission between wild-birds and farm animals. At two farms, a total of 14 one-acre pastures were fenced to each host 12 sheep and 12 goats. For the control group, pastures were set-up with open water tub...
Zeilinger, Markus; Dumanic, Monika; Pichler, Florian; Budinsky, Lubos; Wadsak, Wolfgang; Pallitsch, Katharina; Spreitzer, Helmut; Lanzenberger, Rupert; Hacker, Marcus; Mitterhauser, Markus; Philippe, Cécile
2017-08-14
The MCHR1 is involved in the regulation of energy homeostasis and changes of the expression are linked to a variety of associated diseases, such as diabetes and adiposity. The study aimed at the in vitro and in vivo evaluation of [ 11 C]SNAP-7941 and [ 18 F]FE@SNAP as potential PET-tracers for the MCHR1. Competitive binding studies with non-radioactive derivatives and small-animal PET/CT and MRI brain studies were performed under baseline conditions and tracer displacement with the unlabelled MCHR1 antagonist (±)-SNAP-7941. Binding studies evinced high binding affinity of the non-radioactive derivatives. Small-animal imaging of [ 11 C]SNAP-7941 and [ 18 F]FE@SNAP evinced high tracer uptake in MCHR1-rich regions of the ventricular system. Quantitative analysis depicted a significant tracer reduction after displacement with (±)-SNAP-7941. Due to the high binding affinity of the non-labelled derivatives and the high specific tracer uptake of [ 11 C]SNAP-7941 and [ 18 F]FE@SNAP, there is strong evidence that both radiotracers may serve as highly suitable agents for specific MCHR1 imaging.
Introduction to clinical and laboratory (small-animal) image registration and fusion.
Zanzonico, Pat B; Nehmeh, Sadek A
2006-01-01
Imaging has long been a vital component of clinical medicine and, increasingly, of biomedical research in small-animals. Clinical and laboratory imaging modalities can be divided into two general categories, structural (or anatomical) and functional (or physiological). The latter, in particular, has spawned what has come to be known as "molecular imaging". Image registration and fusion have rapidly emerged as invaluable components of both clinical and small-animal imaging and has lead to the development and marketing of a variety of multi-modality, e.g. PET-CT, devices which provide registered and fused three-dimensional image sets. This paper briefly reviews the basics of image registration and fusion and available clinical and small-animal multi-modality instrumentation.
A thermocouple thermode for small animals
NASA Technical Reports Server (NTRS)
Williams, B. A.
1972-01-01
Thermode composed of two thin-walled stainless steel hypodermic needles and cooper-constantan thermocouple or small thermistor to indicate temperature at point of perfusion is used to measure brain temperature in animals. Because of relatively small size of thermode, structural damage to brain is minimized.
An improved camera trap for amphibians, reptiles, small mammals, and large invertebrates
2017-01-01
Camera traps are valuable sampling tools commonly used to inventory and monitor wildlife communities but are challenged to reliably sample small animals. We introduce a novel active camera trap system enabling the reliable and efficient use of wildlife cameras for sampling small animals, particularly reptiles, amphibians, small mammals and large invertebrates. It surpasses the detection ability of commonly used passive infrared (PIR) cameras for this application and eliminates problems such as high rates of false triggers and high variability in detection rates among cameras and study locations. Our system, which employs a HALT trigger, is capable of coupling to digital PIR cameras and is designed for detecting small animals traversing small tunnels, narrow trails, small clearings and along walls or drift fencing. PMID:28981533
Van Hoeven, Neal; Belser, Jessica A; Szretter, Kristy J; Zeng, Hui; Staeheli, Peter; Swayne, David E; Katz, Jacqueline M; Tumpey, Terrence M
2009-04-01
Although highly pathogenic avian influenza H5N1 viruses have yet to acquire the ability to transmit efficiently among humans, the increasing genetic diversity among these viruses and continued outbreaks in avian species underscore the need for more effective measures for the control and prevention of human H5N1 virus infection. Additional small animal models with which therapeutic approaches against virulent influenza viruses can be evaluated are needed. In this study, we used the guinea pig model to evaluate the relative virulence of selected avian and human influenza A viruses. We demonstrate that guinea pigs can be infected with avian and human influenza viruses, resulting in high titers of virus shedding in nasal washes for up to 5 days postinoculation (p.i.) and in lung tissue of inoculated animals. However, other physiologic indicators typically associated with virulent influenza virus strains were absent in this species. We evaluated the ability of intranasal treatment with human alpha interferon (alpha-IFN) to reduce lung and nasal wash titers in guinea pigs challenged with the reconstructed 1918 pandemic H1N1 virus or a contemporary H5N1 virus. IFN treatment initiated 1 day prior to challenge significantly reduced or prevented infection of guinea pigs by both viruses, as measured by virus titer determination and seroconversion. The expression of the antiviral Mx protein in lung tissue correlated with the reduction of virus titers. We propose that the guinea pig may serve as a useful small animal model for testing the efficacy of antiviral compounds and that alpha-IFN treatment may be a useful antiviral strategy against highly virulent strains with pandemic potential.
Goldhawk, C; Crowe, T; González, L A; Janzen, E; Kastelic, J; Pajor, E; Schwartzkopf-Genswein, K
2014-09-01
Measuring animal-level conditions during transit provides information regarding the true risk of environmental challenges to cattle welfare during transportation. However, due to constraints on placing loggers at the animal level, there is a need to identify appropriate proxy locations. The objective was to evaluate 8 distributions of ceiling-level loggers in the deck and belly compartments of pot-belly trailers for assessing animal-level temperature and humidity during 5 to 18 h commercial transportation of feeder cattle. Ambient conditions during transportation ranged from 3.6 to 45.2°C (20.3 ± 7.61°C, mean ± SD). When considering the entire journey, average differences between ceiling and animal-level temperatures were similar among logger layouts (P > 0.05). The uncertainty in the difference in temperature and humidity between locations was high relative to the magnitude of the difference between animal- and ceiling-level conditions. Single-logger layouts required larger adjustments to predict animal-level conditions within either compartment, during either the entire journey or when the trailer was stationary (P < 0.05). Within certain logger layouts, there were small but significant differences in the ability of regression equations to predict animal-level conditions that were associated with cattle weight and available space relative to body size. Furthermore, evaluation of logger layouts based solely on the entire journey without consideration of stationary periods did not adequately capture variability in layout performance. In conclusion, to adequately monitor animal-level temperature and humidity, 10 loggers distributed throughout the compartment was recommended over single-logger layouts within both the deck and belly compartments of pot-belly trailers transporting feeder cattle in warm weather.
Unmanned aircraft systems as a new source of disturbance for wildlife: A systematic review.
Mulero-Pázmány, Margarita; Jenni-Eiermann, Susanne; Strebel, Nicolas; Sattler, Thomas; Negro, Juan José; Tablado, Zulima
2017-01-01
The use of small Unmanned Aircraft Systems (UAS; also known as "drones") for professional and personal-leisure use is increasing enormously. UAS operate at low altitudes (<500 m) and in any terrain, thus they are susceptible to interact with local fauna, generating a new type of anthropogenic disturbance that has not been systematically evaluated. To address this gap, we performed a review of the existent literature about animals' responses to UAS flights and conducted a pooled analysis of the data to determine the probability and intensity of the disturbance, and to identify the factors influencing animals' reactions towards the small aircraft. We found that wildlife reactions depended on both the UAS attributes (flight pattern, engine type and size of aircraft) and the characteristics of animals themselves (type of animal, life-history stage and level of aggregation). Target-oriented flight patterns, larger UAS sizes, and fuel-powered (noisier) engines evoked the strongest reactions in wildlife. Animals during the non-breeding period and in large groups were more likely to show behavioral reactions to UAS, and birds are more prone to react than other taxa. We discuss the implications of these results in the context of wildlife disturbance and suggest guidelines for conservationists, users and manufacturers to minimize the impact of UAS. In addition, we propose that the legal framework needs to be adapted so that appropriate actions can be undertaken when wildlife is negatively affected by these emergent practices.
Animal damage to conifers on national forests in the Pacific Northwest region.
Glenn L. Crouch
1969-01-01
Animal damage to conifers is a timely topic in the Pacific Northwest. Foresters in this Region are increasingly concerned and perplexed by damage caused by animals to natural and planted seedlings and larger growing stock. Nearly every animal inhabiting for st land is believed to injure seedlings and small trees to some degree. Mice girdle small trees, and bears girdle...
9 CFR 2.1 - Requirements and application.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Section 2.1 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF... maintains a total of four or fewer breeding female dogs, cats, and/or small exotic or wild mammals, such as... than four breeding female dogs, cats, and/or small exotic or wild mammals, regardless of ownership, nor...
European Starlings Are Capable of Discriminating Subtle Size Asymmetries in Paired Stimuli
ERIC Educational Resources Information Center
Swaddle, John P.; Johnson, Charles W.
2007-01-01
Small deviations from bilateral symmetry (fluctuating asymmetries) are cues to fitness differences in some animals. Therefore, researchers have considered whether animals use these small asymmetries as visual cues to determine appropriate behavioral responses (e.g., mate preferences). However, there have been few systematic studies of animals'…
Nowakiewicz, Aneta; Ziółkowska, Grażyna; Zięba, Przemysław; Gnat, Sebastian; Wojtanowicz-Markiewicz, Katarzyna; Trościańczyk, Aleksandra
2016-02-01
The aim of the study was molecular analysis of coagulase-positive isolates of Staphylococcus bacteria obtained from wild animals and evaluation of their resistance to antimicrobial agents. A total of 76 rectal swabs were taken from wild animals. The species of the Staphylococcus isolates was determined by MALDI TOF MS, susceptibility to antimicrobials was evaluated by phenotypic and molecular methods, epidemiological analysis (ADSRRS-fingerprinting) was also carried out. MRSA isolate was typed by MLST and spa-typing. The animals tested, were carriers (n=38) of coagulase-positive Staphylococcus (S. aureus, S. pseudintermedius and S. delphini B). Analyzed isolates were resistant to 1 or 2 antimicrobials, which was confirmed by the presence of genes (blaZ, ermA, ermB, msrA, tetK and tetM). A multi-drug resistant and methicillin-resistant isolate of S. aureus was obtained as well (MRSA, ST8, t1635, PVL-positive and ACME-negative). The ADSRRS-fingerprinting method enabled interspecific and intraspecific differentiation of coagulase-positive Staphylococcus isolates, revealing a certain degree of correlation between the species of the isolate, and the degree of similarity between the isolates. The presence of resistance genes in 13% (5/38) of the isolates obtained from wild animals, including one methicillin-resistant isolate, is relatively small in comparison to the degree of colonization by resistant strains in humans, livestock or pets. Nevertheless, due to the possibility of contact between wild animals, domestic animals and humans, transmission of resistant strains is possible, as suggested by our isolation of a MRSA strain typed as ST8 and specific spa type t1635, which had previously been isolated exclusively from humans. Copyright © 2015 Elsevier Ltd. All rights reserved.
Study of Image Qualities From 6D Robot-Based CBCT Imaging System of Small Animal Irradiator.
Sharma, Sunil; Narayanasamy, Ganesh; Clarkson, Richard; Chao, Ming; Moros, Eduardo G; Zhang, Xin; Yan, Yulong; Boerma, Marjan; Paudel, Nava; Morrill, Steven; Corry, Peter; Griffin, Robert J
2017-01-01
To assess the quality of cone beam computed tomography images obtained by a robotic arm-based and image-guided small animal conformal radiation therapy device. The small animal conformal radiation therapy device is equipped with a 40 to 225 kV X-ray tube mounted on a custom made gantry, a 1024 × 1024 pixels flat panel detector (200 μm resolution), a programmable 6 degrees of freedom robot for cone beam computed tomography imaging and conformal delivery of radiation doses. A series of 2-dimensional radiographic projection images were recorded in cone beam mode by placing and rotating microcomputed tomography phantoms on the "palm' of the robotic arm. Reconstructed images were studied for image quality (spatial resolution, image uniformity, computed tomography number linearity, voxel noise, and artifacts). Geometric accuracy was measured to be 2% corresponding to 0.7 mm accuracy on a Shelley microcomputed tomography QA phantom. Qualitative resolution of reconstructed axial computed tomography slices using the resolution coils was within 200 μm. Quantitative spatial resolution was found to be 3.16 lp/mm. Uniformity of the system was measured within 34 Hounsfield unit on a QRM microcomputed tomography water phantom. Computed tomography numbers measured using the linearity plate were linear with material density ( R 2 > 0.995). Cone beam computed tomography images of the QRM multidisk phantom had minimal artifacts. Results showed that the small animal conformal radiation therapy device is capable of producing high-quality cone beam computed tomography images for precise and conformal small animal dose delivery. With its high-caliber imaging capabilities, the small animal conformal radiation therapy device is a powerful tool for small animal research.
Saumell, Carlos; Lifschitz, Adrián; Baroni, Renato; Fusé, Luis; Bistoletti, Mariana; Sagües, Federica; Bruno, Santiago; Alvarez, Gustavo; Lanusse, Carlos; Alvarez, Luis
2017-03-15
The goal of the current study was to evaluate the comparative efficacy of ivermectin (IVM) against small strongyles (cyathostomins) following its oral and intramuscular (IM) administration, in naturally parasitized horses. The parasitological data were complemented with the assessment of the plasma disposition kinetics of IVM. The trial included two different experiments. In experiment I, 40 horses naturally infected with small strongyles were randomly allocated into four experimental groups (n=10) and treated with IVM (0.2mg/kg) as follows: IVM oral paste, animals were orally treated with Eqvalan ® (IVM 1.87% paste, as the reference formulation) by the oral route; IVM oral solution, animals were orally treated with Remonta ® (IVM 2% solution, as a test formulation); IVM IM solution, animals were IM treated with the test product (Remonta ® IVM 2% solution); and control, animals were kept without treatment as untreated controls. In experiment II, 24 horses naturally parasitized with small strongyles were randomly allocated into the same four experimental groups (n=6) described for experiment I. Faecal samples were individually collected directly from the rectum of each horse prior (day -1) and at 7 and 15 (Experiment I) or 7, 15 and 21 (Experiment II) days after-treatment, to assess the eggs per gram (epg) counts and estimate the efficacy of the treatments. Additionally, the comparative plasma disposition kinetics of IVM in treated animals was assessed in experiment II. In both experiments, an excellent (100%) IVM efficacy was observed after its oral administration (test and reference formulations). However, the IM administration of IVM resulted in a low efficacy (36-64%). Similar IVM plasma concentration was observed after its oral administration as a paste or as a solution. The higher IVM plasma profiles observed after the IM administration accounted for an enhanced systemic availability. The improved IVM efficacy observed against adult cyathostomins after its oral administration can be explained by an enhanced drug exposure of the worms located at the lumen of the large intestine. These findings may have a direct impact on the practical use of macrocyclic lactones in horses. Copyright © 2017 Elsevier B.V. All rights reserved.
Principles of Wound Management and Wound Healing in Exotic Pets.
Mickelson, Megan A; Mans, Christoph; Colopy, Sara A
2016-01-01
The care of wounds in exotic animal species can be a challenging endeavor. Special considerations must be made in regard to the animal's temperament and behavior, unique anatomy and small size, and tendency toward secondary stress-related health problems. It is important to assess the entire patient with adequate systemic evaluation and consideration of proper nutrition and husbandry, which could ultimately affect wound healing. This article summarizes the general phases of wound healing, factors that affect healing, and principles of wound management. Emphasis is placed on novel methods of treating wounds and species differences in wound management and healing. Copyright © 2016 Elsevier Inc. All rights reserved.
2013-01-01
Background Infectious diseases are the second leading cause of death worldwide. In order to better understand and treat them, an accurate evaluation using multi-modal imaging techniques for anatomical and functional characterizations is needed. For non-invasive imaging techniques such as computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET), there have been many engineering improvements that have significantly enhanced the resolution and contrast of the images, but there are still insufficient computational algorithms available for researchers to use when accurately quantifying imaging data from anatomical structures and functional biological processes. Since the development of such tools may potentially translate basic research into the clinic, this study focuses on the development of a quantitative and qualitative image analysis platform that provides a computational radiology perspective for pulmonary infections in small animal models. Specifically, we designed (a) a fast and robust automated and semi-automated image analysis platform and a quantification tool that can facilitate accurate diagnostic measurements of pulmonary lesions as well as volumetric measurements of anatomical structures, and incorporated (b) an image registration pipeline to our proposed framework for volumetric comparison of serial scans. This is an important investigational tool for small animal infectious disease models that can help advance researchers’ understanding of infectious diseases. Methods We tested the utility of our proposed methodology by using sequentially acquired CT and PET images of rabbit, ferret, and mouse models with respiratory infections of Mycobacterium tuberculosis (TB), H1N1 flu virus, and an aerosolized respiratory pathogen (necrotic TB) for a total of 92, 44, and 24 scans for the respective studies with half of the scans from CT and the other half from PET. Institutional Administrative Panel on Laboratory Animal Care approvals were obtained prior to conducting this research. First, the proposed computational framework registered PET and CT images to provide spatial correspondences between images. Second, the lungs from the CT scans were segmented using an interactive region growing (IRG) segmentation algorithm with mathematical morphology operations to avoid false positive (FP) uptake in PET images. Finally, we segmented significant radiotracer uptake from the PET images in lung regions determined from CT and computed metabolic volumes of the significant uptake. All segmentation processes were compared with expert radiologists’ delineations (ground truths). Metabolic and gross volume of lesions were automatically computed with the segmentation processes using PET and CT images, and percentage changes in those volumes over time were calculated. (Continued on next page)(Continued from previous page) Standardized uptake value (SUV) analysis from PET images was conducted as a complementary quantitative metric for disease severity assessment. Thus, severity and extent of pulmonary lesions were examined through both PET and CT images using the aforementioned quantification metrics outputted from the proposed framework. Results Each animal study was evaluated within the same subject class, and all steps of the proposed methodology were evaluated separately. We quantified the accuracy of the proposed algorithm with respect to the state-of-the-art segmentation algorithms. For evaluation of the segmentation results, dice similarity coefficient (DSC) as an overlap measure and Haussdorf distance as a shape dissimilarity measure were used. Significant correlations regarding the estimated lesion volumes were obtained both in CT and PET images with respect to the ground truths (R2=0.8922,p<0.01 and R2=0.8664,p<0.01, respectively). The segmentation accuracy (DSC (%)) was 93.4±4.5% for normal lung CT scans and 86.0±7.1% for pathological lung CT scans. Experiments showed excellent agreements (all above 85%) with expert evaluations for both structural and functional imaging modalities. Apart from quantitative analysis of each animal, we also qualitatively showed how metabolic volumes were changing over time by examining serial PET/CT scans. Evaluation of the registration processes was based on precisely defined anatomical landmark points by expert clinicians. An average of 2.66, 3.93, and 2.52 mm errors was found in rabbit, ferret, and mouse data (all within the resolution limits), respectively. Quantitative results obtained from the proposed methodology were visually related to the progress and severity of the pulmonary infections as verified by the participating radiologists. Moreover, we demonstrated that lesions due to the infections were metabolically active and appeared multi-focal in nature, and we observed similar patterns in the CT images as well. Consolidation and ground glass opacity were the main abnormal imaging patterns and consistently appeared in all CT images. We also found that the gross and metabolic lesion volume percentage follow the same trend as the SUV-based evaluation in the longitudinal analysis. Conclusions We explored the feasibility of using PET and CT imaging modalities in three distinct small animal models for two diverse pulmonary infections. We concluded from the clinical findings, derived from the proposed computational pipeline, that PET-CT imaging is an invaluable hybrid modality for tracking pulmonary infections longitudinally in small animals and has great potential to become routinely used in clinics. Our proposed methodology showed that automated computed-aided lesion detection and quantification of pulmonary infections in small animal models are efficient and accurate as compared to the clinical standard of manual and semi-automated approaches. Automated analysis of images in pre-clinical applications can increase the efficiency and quality of pre-clinical findings that ultimately inform downstream experimental design in human clinical studies; this innovation will allow researchers and clinicians to more effectively allocate study resources with respect to research demands without compromising accuracy. PMID:23879987
Small animal radiotherapy research platforms
NASA Astrophysics Data System (ADS)
Verhaegen, Frank; Granton, Patrick; Tryggestad, Erik
2011-06-01
Advances in conformal radiation therapy and advancements in pre-clinical radiotherapy research have recently stimulated the development of precise micro-irradiators for small animals such as mice and rats. These devices are often kilovolt x-ray radiation sources combined with high-resolution CT imaging equipment for image guidance, as the latter allows precise and accurate beam positioning. This is similar to modern human radiotherapy practice. These devices are considered a major step forward compared to the current standard of animal experimentation in cancer radiobiology research. The availability of this novel equipment enables a wide variety of pre-clinical experiments on the synergy of radiation with other therapies, complex radiation schemes, sub-target boost studies, hypofractionated radiotherapy, contrast-enhanced radiotherapy and studies of relative biological effectiveness, to name just a few examples. In this review we discuss the required irradiation and imaging capabilities of small animal radiation research platforms. We describe the need for improved small animal radiotherapy research and highlight pioneering efforts, some of which led recently to commercially available prototypes. From this, it will be clear that much further development is still needed, on both the irradiation side and imaging side. We discuss at length the need for improved treatment planning tools for small animal platforms, and the current lack of a standard therein. Finally, we mention some recent experimental work using the early animal radiation research platforms, and the potential they offer for advancing radiobiology research.
Kondrup, S V; Anhøj, K P; Rødsgaard-Rosenbeck, C; Lund, T B; Nissen, M H; Sandøe, P
2016-12-10
This study examined the extent to which Danish veterinary practices encounter financially limited clients and how different factors relating to the animal, the client and the veterinarian affect decisions to provide treatment for these clients. 300 small animal practices were invited to participate in an online survey. 195 participated, giving a response rate of 65 per cent. The results show that Danish small animal veterinary practices encounter clients with limited finances regularly: 33.8 per cent of them 3-4 times, 24.6 per cent 5-10 times and 19.5 per cent 1-2 times a month. Only around 9 per cent reported having a written practice policy on handling financially limited clients. Factors affecting decisions to treat include the severity and type of the animal's condition, the medical care needed and the client's expressed emotions. The propensity to treat is significantly higher in female veterinarians and in situations involving unborn animals. The overall conclusion is that small animal veterinary practices often provide treatment to clients who are not able to pay-far beyond what is legally required. This can be considered a major economic and psychological challenge for the practising veterinarians. British Veterinary Association.
T-cell tracking using Cerenkov and Radioluminescence imaging.
Boschi, F; De Sanctis, F; Ugel, S; Spinelli, A E
2018-05-16
Cancer immunotherapy is a promising strategy based on the ability of the immune system to kill selected cells. In the development of an effective T-cell therapy the non-invasive cell tracking methods play a crucial role. Here we investigate the potentialities of T-cell marked with radionuclides in order to detect their localization with imaging techniques in small animal rodents. A protocol to label T-cells with 32 P-ATP was tested and evaluated. The homing of 32 P-ATP labeled T lymphocytes was investigated by Cerenkov luminescence imaging and radioluminescence imaging The first approach relies on the acquisition of Cerenkov photons produced by the beta particles emitted by the 32 P internalized by lymphocytes; the second one on the detection of photons coming from the conversion of radioactive energy in light done by scintillator crystals layered on the animals. The results show that T-cell biodistribution can be optically observed by both Cerenkov and radioluminescence imaging in small animal rodents in in-vivo and ex-vivo acquisitions. T-cell localization in the tumor mass was definitively confirmed by flow cytometry. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Wireless opto-electro neural interface for experiments with small freely behaving animals.
Jia, Yaoyao; Khan, Wasif; Lee, Byunghun; Fan, Bin; Madi, Fatma; Weber, Arthur; Li, Wen; Ghovanloo, Maysam
2018-05-25
We have developed a wireless opto-electro interface (WOENI) device, which combines electrocorticogram (ECoG) recording and optical stimulation for bi-directional neuromodulation on small, freely behaving animals, such as rodents. The device is comprised of two components, a detachable headstage and an implantable polyimide-based substrate. The headstage establishes a Bluetooth Low Energy (BLE) bi-directional data communication with an external custom-designed USB dongle for receiving user commands and optogenetic stimulation patterns, and sending digitalized ECoG data. The functionality and stability of the device were evaluated in vivo on freely behaving rats. When the animal received optical stimulation on the primary visual cortex (V1) and visual stimulation via eyes, spontaneous changes in ECoG signals were recorded from both left and right V1 during 4 consecutive experiments with 7-day intervals over a time span of 21 days following device implantation. Immunostained tissue analyses showed results consistent with ECoG analyses, validating the efficacy of optical stimulation to upregulate the activity of cortical neurons expressing ChR2. The proposed WOENI device is potentially a versatile tool in the studies that involve long-term optogenetic neuromodulation. © 2018 IOP Publishing Ltd.
A Wireless Implantable Micropump for Chronic Drug Infusion Against Cancer
Cobo, Angelica; Sheybani, Roya; Tu, Heidi; Meng, Ellis
2016-01-01
We present an implantable micropump with a miniature form factor and completely wireless operation that enables chronic drug administration intended for evaluation and development of cancer therapies in freely moving small research animals such as rodents. The low power electrolysis actuator avoids the need for heavy implantable batteries. The infusion system features a class E inductive powering system that provides on-demand activation of the pump as well as remote adjustment of the delivery regimen without animal handling. Micropump performance was demonstrated using a model anti-cancer application in which daily doses of 30 μL were supplied for several weeks with less than 6% variation in flow rate within a single pump and less than 8% variation across different pumps. Pumping under different back pressure, viscosity, and temperature conditions were investigated; parameters were chosen so as to mimic in vivo conditions. In benchtop tests under simulated in vivo conditions, micropumps provided consistent and reliable performance over a period of 30 days with less than 4% flow rate variation. The demonstrated prototype has potential to provide a practical solution for remote chronic administration of drugs to ambulatory small animals for research as well as drug discovery and development applications. PMID:26855476
McMillan, Matthew; Brearley, Jacqueline
2013-05-01
To evaluate the interobserver variability in the assignment of the American Society of Anesthesiologists Physical Status Classification (ASA-PSC) to compromised small animal patients amongst a group of veterinary anaesthetists. Anonymous internet survey. Hypothetical case presentations. Sixteen hypothetical small animal cases with differing degrees of physiological or patho-physiological compromise were presented as part of an internet survey. Respondents were asked to assign a single ASA-PSC to each case and also to answer a number of demographic questions. ASA-PSC scores were considered separately and then grouped as scores of I-II and III-V. Agreement was analysed using the modified kappa statistic for multiple observers. Data were then sorted into various demographic groups for further analysis. There were 144 respondents of which 60 (~42%) were anaesthesia diplomates, 24 (~17%) were post-residency (nondiploma holders), 24 (~17%) were current anaesthesia residents, 21 (~15%) were general practitioners, 12 (~8%) were veterinary nurses or technicians, and 3 (~2%) were interns. Although there was a majority agreement (>50% in a single category) in 15 of the 16 cases, ASA-PSC were spread over at least three ASA-PS classifications for every case. Overall agreement was considered only fair (κ = 0.24, mean ± SD agreement 46 ± 7%). When comparing grouped data (ASA-PSC I-II versus III-V) overall agreement remained fair (κ = 0.36, mean ± SD agreement 69 ± 19%). There was no difference in ASA-PSC assignment between any of the demographic groups investigated. This study suggests major discrepancies can occur between observers given identical information when using the ASA-PSC to categorise health status in compromised small animal patients. The significant potential for interobserver variability in classification allocation should be borne in mind when the ASA-PSC is used for clinical, scientific and statistical purposes. © 2013 The Authors. Veterinary Anaesthesia and Analgesia © 2013 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.
Observations Regarding Scatter Fraction and NEC Measurements for Small Animal PET
NASA Astrophysics Data System (ADS)
Yang, Yongfeng; Cherry, S. R.
2006-02-01
The goal of this study was to evaluate the magnitude and origin of scattered radiation in a small-animal PET scanner and to assess the impact of these findings on noise equivalent count rate (NECR) measurements, a metric often used to optimize scanner acquisition parameters and to compare one scanner with another. The scatter fraction (SF) was measured for line sources in air and line sources placed within a mouse-sized phantom (25 mm /spl phi//spl times/70 mm) and a rat-sized phantom (60 mm /spl phi//spl times/150 mm) on the microPET II small-animal PET scanner. Measurements were performed for lower energy thresholds ranging from 150-450 keV and a fixed upper energy threshold of 750 keV. Four different methods were compared for estimating the SF. Significant scatter fractions were measured with just the line source in the field of view, with the spatial distribution of these events consistent with scatter from the gantry and room environment. For mouse imaging, this component dominates over object scatter, and the measured SF is strongly method dependent. The environmental SF rapidly increases as the lower energy threshold decreases and can be more than 30% for an open energy window of 150-750 keV. The object SF originating from the mouse phantom is about 3-4% and does not change significantly as the lower energy threshold increases. The object SF for the rat phantom ranges from 10 to 35% for different energy windows and increases as the lower energy threshold decreases. Because the measured SF is highly dependent on the method, and there is as yet no agreed upon standard for animal PET, care must be exercised when comparing NECR for small objects between different scanners. Differences may be methodological rather than reflecting any relevant difference in the performance of the scanner. Furthermore, these results have implications for scatter correction methods when the majority of the detected scatter does not arise from the object itself.
Sensitivity and specificity of the FAMACHA(©) system in Suffolk sheep and crossbred Boer goats.
Sotomaior, Cristina Santos; Rosalinski-Moraes, Fernanda; da Costa, Alane Rayana Barbosa; Maia, Dhéri; Monteiro, Alda Lúcia Gomes; van Wyk, Jan A
2012-11-23
Sheep and goats are the species of farm animal with the highest growth rate in Paraná State. The main problems facing Paraná State flocks are gastrointestinal parasites and anthelmintic resistance. One of the newest resources used to slow down the development of anthelmintic resistance is the FAMACHA(©) system, a selective method useful for controlling gastrointestinal verminosis in small ruminants. The purpose of the present research was to evaluate the sensitivity and specificity of the FAMACHA(©) system in sheep and goats and to compare the results for both species. The conjunctivae of 83 Suffolk ewes and 60 adult crossbred Boer does were evaluated by the same trained person using the FAMACHA(©) system. The packed cell value (PCV) served as the gold standard for clinical FAMACHA(©) evaluation. To calculate the sensitivity and specificity of the FAMACHA(©) system, different criteria were adopted in turn: animals classified as FAMACHA(©) (F(©)) 4 and 5, or 3, 4 and 5, were considered to be anemic (positive test), and animals classified as F(©)1, 2 and 3, or 1 and 2 were considered to be non-anemic (negative test). Three standard values of PCV, namely ≤19%, ≤18% or ≤15%, were used to confirm anemia. At all cut-off levels, the sensitivity increased if F(©)3 animals were included as being anemic. However, changes in levels of sensitivity were associated with reciprocal changes in specificity. The sensitivity was higher for sheep than for goats, excepting when the criteria included PCV≤18 and F(©)3, F(©)4 and F(©)5 were considered positive. In contrast, the specificity was always lower in sheep for any criteria adopted. Other than in goats, using the ≤15 cut-off level for sheep, it is possible to opt not to drench the animals that were shown to be F(©)3 because the sensitivity is still high, indicating that few animals that should have been drenched were overlooked. In goats, in contrast, the low sensitivity at all cut-off levels made it too risky to leave F(©)3 animals undrenched. Even though the number of correct treatments for goats was always higher than that for sheep, the opposite was true for the kappa index for all the criteria tested. Therefore, the FAMACHA(©) system is suitable for the identification of anemic animals of both species. It is necessary that all small ruminants classified as FAMACHA(©) level 3 are also treated to increase the sensitivity of the method. Copyright © 2012 Elsevier B.V. All rights reserved.
Maxwell, Gavin; Aeby, Pierre; Ashikaga, Takao; Bessou-Touya, Sandrine; Diembeck, Walter; Gerberick, Frank; Kern, Petra; Marrec-Fairley, Monique; Ovigne, Jean-Marc; Sakaguchi, Hitoshi; Schroeder, Klaus; Tailhardat, Magali; Teissier, Silvia; Winkler, Petra
2011-01-01
Allergic contact dermatitis is a delayed-type hypersensitivity reaction induced by small reactive chemicals (haptens). Currently, the sensitising potential and potency of new chemicals is usually characterised using data generated via animal studies, such as the local lymph node assay (LLNA). There are, however, increasing public and political concerns regarding the use of animals for the testing of new chemicals. Consequently, the development of in vitro, in chemico or in silico models for predicting the sensitising potential and/or potency of new chemicals is receiving widespread interest. The Colipa Skin Tolerance task force currently collaborates with and/or funds several academic research groups to expand our understanding of the molecular and cellular events occurring during the acquisition of skin sensitisation. Knowledge gained from this research is being used to support the development and evaluation of novel alternative approaches for the identification and characterisation of skin sensitizing chemicals. At present three non-animal test methods (Direct Peptide Reactivity Assay (DPRA), Myeloid U937 Skin Sensitisation Test (MUSST) and human Cell Line Activation Test (hCLAT)) have been evaluated in Colipa interlaboratory ring trials for their potential to predict skin sensitisation potential and were recently submitted to ECVAM for formal pre-validation. Data from all three test methods will now be used to support the study and development of testing strategy approaches for skin sensitiser potency prediction. This publication represents the current viewpoint of the cosmetics industry on the feasibility of replacing the need for animal test data for informing skin sensitisation risk assessment decisions.
Noël, P; Fagot, H; Fabre, J M; Mann, C; Quenet, F; Guillon, F; Baumel, H; Domergue, J
1994-01-01
Laparoscopic intestinal anastomosis is not very reliable and needs to be evaluate in an experimental model in animals before being performed in man. The purpose of this study was to evaluate the feasibility, efficacy and safety of manual anastomosis comparatively to the standard stapling suture. Twenty female pigs weighing 20 +/- 5 kg. were used for this study. A 5 cm ileal segment resection was performed under laparoscopy. The animals were assigned to 2 groups. Group I: 10 animals underwent end-to-end hand-swen anastomosis with Polyglactin 910, dec 1.5. Group II: 10 animals underwent side-to-side anastomosis using the Endo stapler. Operating time and anastomosis time were compared using the Mann-Whitney test for statistical analysis. On the 15th postoperative day, the animals were sacrificed and the anastomoses were evaluated. There was no operating death in the 2 groups. The operative time was significantly longer in group I than in group II (p < 0.01), with 180 +/- 40 min vs 49 +/- 25 min respectively. This difference was due to the anastomosis time of 130 +/- 40 min vs 16 +/- 6 min respectively (p < 0.01). There was 1 postoperative death related to fistula and peritonitis in group I and none in group II. The post-operative follow-ing showed 5 anastomotic leakages (4 in group I and 1 in group II) and 2 relative stenoses in group I. This study shows the simplicity and rapidity of performing stapling intestinal anastomosis under laparoscopy. Hand-sewn anastomosis is technically more difficult to perform under laparoscopy and requires a greater experience.
Animal Well-Being in Small Poultry Flocks: Improving bird health and product quality
USDA-ARS?s Scientific Manuscript database
Consumer interest in farm animal welfare is increasing and, while there is little legislation, voluntary welfare assurance programs exist; however, most small poultry producers do not participate in these programs. Raising birds in small flocks has some inherent welfare advantages, such as ample sp...
Mélade, Julien; Dietrich, Muriel; Ramasindrazana, Beza; Soarimalala, Voahangy; Lagadec, Erwan; le Minter, Gildas; Tortosa, Pablo; Heraud, Jean-Michel; de Lamballerie, Xavier; Goodman, Steven M.; Dellagi, Koussay
2014-01-01
ABSTRACT The Paramyxoviridae form an increasingly diverse viral family, infecting a wide variety of different hosts. In recent years, they have been linked to disease emergence in many different animal populations and in humans. Bats and rodents have been identified as major animal populations capable of harboring paramyxoviruses, and host shifting between these animals is likely to be an important driving factor in the underlying evolutionary processes that eventually lead to disease emergence. Here, we have studied paramyxovirus circulation within populations of endemic and introduced wild small mammals of the southwestern Indian Ocean region and belonging to four taxonomic orders: Rodentia, Afrosoricida, Soricomorpha, and Chiroptera. We report elevated infection levels as well as widespread paramyxovirus dispersal and frequent host exchange of a newly emerging genus of the Paramyxoviridae, currently referred to as the unclassified morbillivirus-related viruses (UMRVs). In contrast to other genera of the Paramyxoviridae, where bats have been shown to be a key host species, we show that rodents (and, in particular, Rattus rattus) are significant spreaders of UMRVs. We predict that the ecological particularities of the southwestern Indian Ocean, where small mammal species often live in densely packed, multispecies communities, in combination with the increasing invasion of R. rattus and perturbations of endemic animal communities by active anthropological development, will have a major influence on the dynamics of UMRV infection. IMPORTANCE Identification of the infectious agents that circulate within wild animal reservoirs is essential for several reasons: (i) infectious disease outbreaks often originate from wild fauna; (ii) anthropological expansion increases the risk of contact between human and animal populations and, as a result, the risk of disease emergence; (iii) evaluation of pathogen reservoirs helps in elaborating preventive measures to limit the risk of disease emergence. Many paramyxoviruses for which bats and rodents serve as major reservoirs have demonstrated their potential to cause disease in humans and animals. In the context of the biodiversity hot spot of southwestern Indian Ocean islands and their rich endemic fauna, we show that highly diverse UMRVs exchange between various endemic animal species, and their dissemination likely is facilitated by the introduced Rattus rattus. Hence, many members of the Paramyxoviridae appear well adapted for the study of the viral phylodynamics that may be associated with disease emergence. PMID:24829336
Wu, C; de Jong, J R; Gratama van Andel, H A; van der Have, F; Vastenhouw, B; Laverman, P; Boerman, O C; Dierckx, R A J O; Beekman, F J
2011-09-21
Attenuation of photon flux on trajectories between the source and pinhole apertures affects the quantitative accuracy of reconstructed single-photon emission computed tomography (SPECT) images. We propose a Chang-based non-uniform attenuation correction (NUA-CT) for small-animal SPECT/CT with focusing pinhole collimation, and compare the quantitative accuracy with uniform Chang correction based on (i) body outlines extracted from x-ray CT (UA-CT) and (ii) on hand drawn body contours on the images obtained with three integrated optical cameras (UA-BC). Measurements in phantoms and rats containing known activities of isotopes were conducted for evaluation. In (125)I, (201)Tl, (99m)Tc and (111)In phantom experiments, average relative errors comparing to the gold standards measured in a dose calibrator were reduced to 5.5%, 6.8%, 4.9% and 2.8%, respectively, with NUA-CT. In animal studies, these errors were 2.1%, 3.3%, 2.0% and 2.0%, respectively. Differences in accuracy on average between results of NUA-CT, UA-CT and UA-BC were less than 2.3% in phantom studies and 3.1% in animal studies except for (125)I (3.6% and 5.1%, respectively). All methods tested provide reasonable attenuation correction and result in high quantitative accuracy. NUA-CT shows superior accuracy except for (125)I, where other factors may have more impact on the quantitative accuracy than the selected attenuation correction.
Hippen, Keli L; Watkins, Benjamin; Tkachev, Victor; Lemire, Amanda M; Lehnen, Charles; Riddle, Megan J; Singh, Karnail; Panoskaltsis-Mortari, Angela; Vanhove, Bernard; Tolar, Jakub; Kean, Leslie S; Blazar, Bruce R
2016-12-01
Graft-versus-host disease (GVHD) is a severe complication of hematopoietic stem cell transplantation. Current therapies to prevent alloreactive T cell activation largely cause generalized immunosuppression and may result in adverse drug, antileukemia and antipathogen responses. Recently, several immunomodulatory therapeutics have been developed that show efficacy in maintaining antileukemia responses while inhibiting GVHD in murine models. To analyze efficacy and better understand immunological tolerance, escape mechanisms, and side effects of clinical reagents, testing of species cross-reactive human agents in large animal GVHD models is critical. We have previously developed and refined a nonhuman primate (NHP) large animal GVHD model. However, this model is not readily amenable to semi-high throughput screening of candidate clinical reagents. Here, we report a novel, optimized NHP xenogeneic GVHD (xeno-GVHD) small animal model that recapitulates many aspects of NHP and human GVHD. This model was validated using a clinically available blocking, monovalent anti-CD28 antibody (FR104) whose effects in a human xeno-GVHD rodent model are known. Because human-reactive reagents may not be fully cross-reactive or effective in vivo on NHP immune cells, this NHP xeno-GVHD model provides immunological insights and direct testing on NHP-induced GVHD before committing to the intensive NHP studies that are being increasingly used for detailed evaluation of new immune therapeutic strategies before human trials.
Larsson, Daniel H; Lundström, Ulf; Westermark, Ulrica K; Arsenian Henriksson, Marie; Burvall, Anna; Hertz, Hans M
2013-02-01
Small-animal studies require images with high spatial resolution and high contrast due to the small scale of the structures. X-ray imaging systems for small animals are often limited by the microfocus source. Here, the authors investigate the applicability of liquid-metal-jet x-ray sources for such high-resolution small-animal imaging, both in tomography based on absorption and in soft-tissue tumor imaging based on in-line phase contrast. The experimental arrangement consists of a liquid-metal-jet x-ray source, the small-animal object on a rotating stage, and an imaging detector. The source-to-object and object-to-detector distances are adjusted for the preferred contrast mechanism. Two different liquid-metal-jet sources are used, one circulating a Ga∕In∕Sn alloy and the other an In∕Ga alloy for higher penetration through thick tissue. Both sources are operated at 40-50 W electron-beam power with ∼7 μm x-ray spots, providing high spatial resolution in absorption imaging and high spatial coherence for the phase-contrast imaging. High-resolution absorption imaging is demonstrated on mice with CT, showing 50 μm bone details in the reconstructed slices. High-resolution phase-contrast soft-tissue imaging shows clear demarcation of mm-sized tumors at much lower dose than is required in absorption. This is the first application of liquid-metal-jet x-ray sources for whole-body small-animal x-ray imaging. In absorption, the method allows high-resolution tomographic skeletal imaging with potential for significantly shorter exposure times due to the power scalability of liquid-metal-jet sources. In phase contrast, the authors use a simple in-line arrangement to show distinct tumor demarcation of few-mm-sized tumors. This is, to their knowledge, the first small-animal tumor visualization with a laboratory phase-contrast system.
A comparison study of different RF shields for an 8-element transceive small animal array at 9.4T.
Jin, Jin; Li, Yu; Liu, Feng; Weber, Ewald; Crozier, Stuart
2011-01-01
In this study, three types of radio-frequency shields are studied and compared in the context of ultra-high field small-animal magnetic resonance imaging. It has been demonstrated that the coil penetration depth and mutual coupling between the coils depend heavily on the type of shield employed. The results were used to guide the design of a 9.4T 8-element transceive small animal array, which provides high overall coil penetration.
An MRI system for imaging neonates in the NICU: initial feasibility study.
Tkach, Jean A; Hillman, Noah H; Jobe, Alan H; Loew, Wolfgang; Pratt, Ron G; Daniels, Barret R; Kallapur, Suhas G; Kline-Fath, Beth M; Merhar, Stephanie L; Giaquinto, Randy O; Winter, Patrick M; Li, Yu; Ikegami, Machiko; Whitsett, Jeffrey A; Dumoulin, Charles L
2012-11-01
Transporting premature infants from a neonatal intensive care unit (NICU) to a radiology department for MRI has medical risks and logistical challenges. To develop a small 1.5-T MRI system for neonatal imaging that can be easily installed in the NICU and to evaluate its performance using a sheep model of human prematurity. A 1.5-T MRI system designed for orthopedic use was adapted for neonatal imaging. The system was used for MRI examinations of the brain, chest and abdomen in 12 premature lambs during the first hours of life. Spin-echo, fast spin-echo and gradient-echo MR images were evaluated by two pediatric radiologists. All animals remained physiologically stable throughout the imaging sessions. Animals were imaged at two or three time points. Seven brain MRI examinations were performed in seven different animals, 23 chest examinations in 12 animals and 19 abdominal examinations in 11 animals. At each anatomical location, high-quality images demonstrating good spatial resolution, signal-to-noise ratio and tissue contrast were routinely obtained within 30 min using standard clinical protocols. Our preliminary experience demonstrates the feasibility and potential of the neonatal MRI system to provide state-of-the-art MRI capabilities within the NICU. Advantages include overall reduced cost and site demands, lower acoustic noise, improved ease of access and reduced medical risk to the neonate.
Effects of HIV-1 on Cognition in Humanized NSG Mice
NASA Astrophysics Data System (ADS)
Akhter, Sidra Pervez
Host species specificity of human immunodeficiency virus (HIV) creates a challenge to study the pathology, diagnostic tools, and therapeutic agents. The closely related simian immunodeficiency virus and studies of neurocognitive impairments on transgenic animals expressing partial viral genome have significant limitations. The humanized mice model provides a small animal system in which a human immune system can be engrafted and immunopathobiology of HIV-1 infection can be studied. However, features of HIV-associated neurocognitive disorders (HAND) were not evaluated in this model. Open field activity test was selected to characterize behavior of original strain NOD/scid-IL-2Rgammac null (NSG) mice, effects of engraftment of human CD34+ hematopoietic stem cells (HSCs) and functional human immune system (huNSG), and finally, investigate the behavior changes induced by chronic HIV-1 infection. Long-term infected HuNSG mice showed the loss of working memory and increased anxiety in the open field. Additionally, these animals were utilized for evaluation of central nervous system metabolic and structural changes. Detected behavioral abnormalities are correlated with obtained neuroimaging and histological abnormalities published.
Hartnack, Sonja; Springer, Svenja; Pittavino, Marta; Grimm, Herwig
2016-02-04
Euthanasia of pets has been described by veterinarians as "the best and the worst" of the profession. The most commonly mentioned ethical dilemmas veterinarians face in small animal practice are: limited treatment options due to financial constraints, euthanizing of healthy animals and owners wishing to continue treatment of terminally ill animals. The aim of the study was to gain insight into the attitudes of Austrian veterinarians towards euthanasia of small animals. This included assessing their agreement with euthanasia in exemplified case scenarios, potentially predicted by demographic variables (e.g. gender, age, working in small animal practice, employment, working in a team, numbers of performed euthanasia). Further describing the veterinarians' agreement with a number of different normative and descriptive statements, including coping strategies. A questionnaire with nine euthanasia scenarios, 26 normative and descriptive statements, and demographic data were sent to all members of the Austrian Chamber of Veterinary Surgeons (n = 2478). In total, 486 veterinarians answered sufficiently completely to enable analyses. Responses were first explored descriptively before being formally analysed using linear regression and additive Bayesian networks - a multivariate regression methodology - in order to identify joint relationships between the demographic variables, the statements and each of the nine euthanasia scenarios. Mutual dependencies between the demographic variables were found, i.e. female compared to male veterinarians worked mostly in small animal practice, and working mostly in small animal practice was linked to performing more euthanasia per month. Gender and age were found to be associated with views on euthanasia: female veterinarians and veterinarians having worked for less years were more likely to disagree with euthanasia in at least some of the convenience euthanasia scenarios. The number of veterinarians working together was found to be the variable with the highest number of links to other variables, demographic as well as ethical statements. This highlights the role of a team potentially providing support in stressful situations. The results are useful for a better understanding of coping strategies for veterinarians with moral stress due to euthanasia of small animals.
Small-animal research imaging devices.
Fine, Eugene J; Herbst, Lawrence; Jelicks, Linda A; Koba, Wade; Theele, Daniel
2014-01-01
The scientific study of living animals may be dated to Aristotle's original dissections, but modern animal studies are perhaps a century in the making, and advanced animal imaging has emerged only during the past few decades. In vivo imaging now occupies a growing role in the scientific research paradigm. Imaging of small animals has been particularly useful to help understand human molecular biology and pathophysiology using rodents, especially using genetically engineered mice (GEM) with spontaneous diseases that closely mimic human diseases. Specific examples of GEM models of veterinary diseases exist, but in general, GEM for veterinary research has lagged behind human research applications. However, the development of spontaneous disease models from GEM may also hold potential for veterinary research. The imaging techniques most widely used in small-animal research are CT, PET, single-photon emission CT, MRI, and optical fluorescent and luminescent imaging. Copyright © 2014 Elsevier Inc. All rights reserved.
Jesmer, Brett R.; Goheen, Jacob R.; Monteith, Kevin L.; Kauffman, Matthew J.
2017-01-01
Glucocorticoids (GC) and triiodothyronine (T3) are two endocrine markers commonly used to quantify resource limitation, yet the relationships between these markers and the energetic state of animals has been studied primarily in small-bodied species in captivity. Free-ranging animals, however, adjust energy intake in accordance with their energy reserves, a behavior known as state-dependent foraging. Further, links between life-history strategies and metabolic allometries cause energy intake and energy reserves to be more strongly coupled in small animals relative to large animals. Because GC and T3 may reflect energy intake or energy reserves, state-dependent foraging and body size may cause endocrine–energy relationships to vary among taxa and environments. To extend the utility of endocrine markers to large-bodied, free-ranging animals, we evaluated how state-dependent foraging, energy reserves, and energy intake influenced fecal GC and fecal T3 concentrations in free-ranging moose (Alces alces). Compared with individuals possessing abundant energy reserves, individuals with few energy reserves had higher energy intake and high fecal T3 concentrations, thereby supporting state-dependent foraging. Although fecal GC did not vary strongly with energy reserves, individuals with higher fecal GC tended to have fewer energy reserves and substantially greater energy intake than those with low fecal GC. Consequently, individuals with greater energy intake had both high fecal T3 and high fecal GC concentrations, a pattern inconsistent with previous documentation from captive animal studies. We posit that a positive relationship between GC and T3 may be expected in animals exhibiting state-dependent foraging if GC is associated with increased foraging and energy intake. Thus, we recommend that additional investigations of GC– and T3–energy relationships be conducted in free-ranging animals across a diversity of body size and life-history strategies before these endocrine markers are applied broadly to wildlife conservation and management.
Sandoval, John A; Lou, Derek; Engum, Scott A; Fisher, Lisa M; Bouchard, Christine M; Davis, Mary M; Grosfeld, Jay L
2006-03-01
Diaphragmatic reconstruction remains a challenging problem. There is limited information concerning the use of small intestinal submucosa (SIS) in congenital diaphragmatic hernia repair. A canine model was used to evaluate the use of a SIS patch in diaphragmatic reconstruction. Eleven beagle puppies (1.6-4.2 kg, 8 weeks old) underwent left subcostal laparotomy, central left hemidiaphragm excision (2 x 7 cm, 50% loss), and reconstruction with a 4-ply group I (n = 5) or 8-ply group II (n = 6) SIS patch. Chest radiographs were taken at time of operation and 3 and 6 months postoperatively. Animals were killed at 6 months. Adhesion formation (both pleural and abdominal), gross visual evaluation of the patch, and histology were compared. In group I (4-ply), 1 animal died at 3 months from patch deterioration accompanied by stomach herniation that resulted in respiratory failure. In the 4 remaining animals, chest radiographs showed no evidence of herniation or eventration. On physical examination, there was no evidence of chest wall deformity. During gross surgical examination, the 4-ply patches showed thinning, multiple defects, and liver herniation in 3 animals. In 1 pup, the patch was thickened, intact, well incorporated at the repair site, and adherent to the liver and spleen. In group II (8-ply), 1 animal died of cardiopulmonary failure in the early postoperative period. In the other 5 animals, chest radiographs showed evidence of eventration in 1. On gross examination the patch adhered to the liver in all 5 surviving animals. In 4, the patches were thickened, viable, but had some shrinkage. One patch pulled away from the native diaphragm laterally; however, no visceral herniation was present. In the 1 animal with eventration, there was no evidence of a patch. Adhesion scores (AS) were graded and determined by the sum of extent (0-4), type (0-4), and tenacity (0-3). Average abdominal AS in group I was 5.6 +/- 0.8 vs 10.2 +/- 0.2 (P = .079) for group II. Average lung AS was 0.6 +/- 0.6 in group I vs 3.8 +/- 1.1 (P = .0476) for group II. Histological examination showed group II patches had greater collagen deposition with central calcification and mild inflammation within the residual graft, whereas group I patches were much thinner and were composed of granulation tissue without evidence of residual graft. These data indicate that 8-ply SIS repair of diaphragmatic defects was superior (80%; 4/5 to 4-ply, 20%; 1/5, success). Organ adherence appears to be necessary for neovascularization of the SIS composite. Eight-ply grafts appear to be more durable and persist for a longer period, which may improve neovascularization. Long-term follow-up to evaluate remodeling characteristics of the patch material is required.
Oztürk, Hayrettin; Dokucu, Ali Ihsan; Yağmur, Yusuf; Sari, Ibrahim
2002-09-01
To evaluate whether L-arginine methyl ester (L-Arg) can improve the structure of the small intestine and enhance adaptation in an experimental model of short-bowel syndrome (SBS), 40 Sprague-Dawley rats were divided randomly into four groups of 10 each. In one group only a laparotomy was performed (G1). The remaining 30 rats underwent 90% small-bowel resection (SBR) and formed the three experimental groups: the SBR/untreated group (G2), the SBR/L-NAME-treated group (G3), and the SBR/ L-Arg-treated group (G4). Rats in G2 received no therapeutic treatment. Rats in the SBR/L-NAME and SBR/L-Arg treated groups received N-G-nitro-L-arginine-methyl ester (L-NAME) and L-Arg intraperitoneally for 3 weeks, respectively. The animals were weighed daily. All rats underwent a relaparotomy on day 21 of the experiment. Remnant small bowel was excised and evaluated for villus height and crypt cell mitoses. After the 90% SBR, all animals had from diarrhea and weight loss between the 1st and 6th postoperative days (POD). The body weight of the SBR/L-Arg group showed significant increases at POD 10 and 21 in comparison to the SBR/untreated and SBR/L-NAME groups (P < 0.001). The rats treated with L-Arg had significantly greater villus height and crypt-cell mitoses compared to the other groups (P < 0.0001, P < 0.001). These observations suggest that L-Arg treatment increases villus height and crypt-cell mitoses after massive SBR and may play a considerable role in the mucosal adaptive response in SBS in rats.
Tang, Shaojie; Yang, Yi; Tang, Xiangyang
2012-01-01
Interior tomography problem can be solved using the so-called differentiated backprojection-projection onto convex sets (DBP-POCS) method, which requires a priori knowledge within a small area interior to the region of interest (ROI) to be imaged. In theory, the small area wherein the a priori knowledge is required can be in any shape, but most of the existing implementations carry out the Hilbert filtering either horizontally or vertically, leading to a vertical or horizontal strip that may be across a large area in the object. In this work, we implement a practical DBP-POCS method with radial Hilbert filtering and thus the small area with the a priori knowledge can be roughly round (e.g., a sinus or ventricles among other anatomic cavities in human or animal body). We also conduct an experimental evaluation to verify the performance of this practical implementation. We specifically re-derive the reconstruction formula in the DBP-POCS fashion with radial Hilbert filtering to assure that only a small round area with the a priori knowledge be needed (namely radial DBP-POCS method henceforth). The performance of the practical DBP-POCS method with radial Hilbert filtering and a priori knowledge in a small round area is evaluated with projection data of the standard and modified Shepp-Logan phantoms simulated by computer, followed by a verification using real projection data acquired by a computed tomography (CT) scanner. The preliminary performance study shows that, if a priori knowledge in a small round area is available, the radial DBP-POCS method can solve the interior tomography problem in a more practical way at high accuracy. In comparison to the implementations of DBP-POCS method demanding the a priori knowledge in horizontal or vertical strip, the radial DBP-POCS method requires the a priori knowledge within a small round area only. Such a relaxed requirement on the availability of a priori knowledge can be readily met in practice, because a variety of small round areas (e.g., air-filled sinuses or fluid-filled ventricles among other anatomic cavities) exist in human or animal body. Therefore, the radial DBP-POCS method with a priori knowledge in a small round area is more feasible in clinical and preclinical practice.
Stickel, Jennifer R; Qi, Jinyi; Cherry, Simon R
2007-01-01
With the increasing use of in vivo imaging in mouse models of disease, there are many interesting applications that demand imaging of organs and tissues with submillimeter resolution. Though there are other contributing factors, the spatial resolution in small-animal PET is still largely determined by the detector pixel dimensions. In this work, a pair of lutetium oxyorthosilicate (LSO) arrays with 0.5-mm pixels was coupled to multichannel photomultiplier tubes and evaluated for use as high-resolution PET detectors. Flood histograms demonstrated that most crystals were clearly identifiable. Energy resolution varied from 22% to 38%. The coincidence timing resolution was 1.42-ns full width at half maximum (FWHM). The intrinsic spatial resolution was 0.68-mm FWHM as measured with a 30-gauge needle filled with (18)F. The improvement in spatial resolution in a tomographic setting is demonstrated using images of a line source phantom reconstructed with filtered backprojection and compared with images obtained from 2 dedicated small-animal PET scanners. Finally, a projection image of the mouse foot is shown to demonstrate the application of these 0.5-mm LSO detectors to a biologic task. A pair of highly pixelated LSO detections has been constructed and characterized for use as high-spatial-resolution PET detectors. It appears that small-animal PET systems capable of a FWHM spatial resolution of 600 microm or less are feasible and should be pursued.
Irreversible electroporation of the pancreas is feasible and safe in a porcine survival model.
Fritz, Stefan; Sommer, Christof M; Vollherbst, Dominik; Wachter, Miguel F; Longerich, Thomas; Sachsenmeier, Milena; Knapp, Jürgen; Radeleff, Boris A; Werner, Jens
2015-07-01
Use of thermal tumor ablation in the pancreatic parenchyma is limited because of the risk of pancreatitis, pancreatic fistula, or hemorrhage. This study aimed to evaluate the feasibility and safety of irreversible electroporation (IRE) in a porcine model. Ten pigs were divided into 2 study groups. In the first group, animals received IRE of the pancreatic tail and were killed after 60 minutes. In the second group, animals received IRE at the head of the pancreas and were followed up for 7 days. Clinical parameters, computed tomography imaging, laboratory results, and histology were obtained. All animals survived IRE ablation, and no cardiac adverse effects were noted. Sixty minutes after IRE, a hypodense lesion on computed tomography imaging indicated the ablation zone. None of the animals developed clinical signs of acute pancreatitis. Only small amounts of ascites fluid, with a transient increase in amylase and lipase levels, were observed, indicating that no pancreatic fistula occurred. This porcine model shows that IRE is feasible and safe in the pancreatic parenchyma. Computed tomography imaging reveals significant changes at 60 minutes after IRE and therefore might serve as an early indicator of therapeutic success. Clinical studies are needed to evaluate the efficacy of IRE in pancreatic cancer.
Lü, Rui
2017-09-01
Dynamic detection of transient redox changes in living cells and animals has broad implications for human health and disease diagnosis, because intracellular redox homeostasis regulated by reactive oxygen species (ROS) plays important role in cell functions, normal physiological functions and some serious human diseases (e.g., cancer, Alzheimer's disease, diabetes, etc.) usually have close relationship with the intracellular redox status. Small-molecule ROS-responsive fluorescent probes can act as powerful tools for dynamic detection of ROS and redox changes in living cells and animals through fluorescence imaging techniques; and great advances have been achieved recently in the design and synthesis of small-molecule ROS-responsive fluorescent probes. This article highlights up-to-date achievements in designing and using the reaction-based small-molecule fluorescent probes (with high sensitivity and selectivity to ROS and redox cycles) in the dynamic detection of ROS and transient redox changes in living cells and animals through fluorescence imaging. Copyright © 2017. Published by Elsevier Ltd.
Vaccination of small Asian mongoose (Herpestes javanicus) against rabies.
Blanton, Jesse D; Meadows, Anastasia; Murphy, Staci M; Manangan, Jamie; Hanlon, Cathleen A; Faber, Marie-Luise; Dietzschold, Bernhard; Rupprecht, Charles E
2006-07-01
Oral vaccination of free-ranging wildlife is a promising technique in rabies control. The small Asian mongoose (Herpestes javanicus) is an important reservoir of rabies on several Caribbean islands, but no vaccines have been evaluated for this species. Captive mongooses were used to test the safety and efficacy of the commercially licensed vaccinia-rabies glycoprotein (V-RG) recombinant vaccine and a newly developed genetically engineered oral rabies virus vaccine (SPBNGA-S). In one study using V-RG, no vaccinated animals developed detectable rabies virus-neutralizing antibodies, and all but one died after experimental challenge with rabies virus. In contrast, all animals given SPBNGA-S demonstrated seroconversion within 7 to 14 days after vaccination and survived rabies virus challenge. On the basis of these preliminary results indicating the greater efficacy of SPBNGA-S vs. V-RG vaccine, additional investigations will be necessary to determine the optimal dose and duration of vaccination, as well as incorporation of the SPBNGA-S vaccine into edible bait.
Tomorrow's vector vaccines for small ruminants.
Kyriakis, C S
2015-12-14
Inactivated and attenuated vaccines have contributed to the control or even the eradication of significant animal pathogens. However, these traditional vaccine technologies have limitations and disadvantages. Inactivated vaccines lack efficacy against certain pathogens, while attenuated vaccines are not always as safe. New technology vaccines, namely DNA and recombinant viral vector vaccines, are being developed and tested against pathogens of small ruminants. These vaccines induce both humoral and cellular immune responses, are safe to manufacture and use and can be utilized in strategies for differentiation of infected from vaccinated animals. Although there are more strict regulatory requirements for the safety standards of these vaccines, once a vaccine platform is evaluated and established, effective vaccines can be rapidly produced and deployed in the field to prevent spread of emerging pathogens. The present article offers an introduction to these next generation technologies and examples of vaccines that have been tested against important diseases of sheep and goats. Copyright © 2015 Elsevier B.V. All rights reserved.
Prevalence of Rift Valley fever infection in ruminants in Madagascar after the 2008 outbreak.
Jeanmaire, Elisabeth Marie; Rabenarivahiny, René; Biarmann, Marcellin; Rabibisoa, Lalao; Ravaomanana, Fleurette; Randriamparany, Tantely; Andriamandimby, Soa Fy; Diaw, Cécile Squarzoni; Fenozara, Peter; de La Rocque, Stéphane; Reynes, Jean-Marc
2011-04-01
A Rift Valley fever (RVF) outbreak occurred in Madagascar from January to May 2008. The objectives of this study were (1) to assess the current and past circulation of RVF virus (RVFV) in livestock in Madagascar and (2) to evaluate the extent and magnitude of the 2008 RVF outbreak in livestock. The results of a country-wide serosurvey conducted in August 2008 on small and large ruminants are reported here. The study included 3437 cattle and 989 small ruminants (227 sheep and 762 goats) sampled in 30 of the 111 Malagasy districts, selected to be representative of the different ecozones and livestock density areas. Sera of animals were tested for the detection of immunoglobulins M (IgM) and G (IgG) against RVFV using commercial enzyme-linked immunosorbent assays kits. Recent infections (presence of IgM against RVFV) were detected in only 9 cattle (0.3% [0.1-0.4]) and 33 small ruminant (3.3% [2.2-4.5]) samples. Past infections (presence of IgG and absence of IgM against RVFV) were detected in 887 cattle (25.8% [24.3-27.3]) and 244 small ruminant (24.7% [22.0-27.4]) samples. Past infections were detected in all sampled sites. All ecozones were affected. In the southern and northwestern areas, the prevalence of cattle showing evidence of past infection with RVFV increased with the age of the animals. Our results suggest that there has been country-wide circulation of RVFV in 2008 in Madagascar, including in parts of the country where no clinical illness, either in animals or in humans, was reported. The data also suggest that the southern and northwestern areas may be endemic for RVFV, and that the virus may spread when ecological conditions are favorable for its amplification.
History, ethics, advantages and limitations of experimental models for hepatic ablation.
Ong, Seok Ling; Gravante, Gianpiero; Metcalfe, Matthew S; Dennison, Ashley R
2013-01-14
Numerous techniques developed in medicine require careful evaluation to determine their indications, limitations and potential side effects prior to their clinical use. At present this generally involves the use of animal models which is undesirable from an ethical standpoint, requires complex and time-consuming authorization, and is very expensive. This process is exemplified in the development of hepatic ablation techniques, starting experiments on explanted livers and progressing to safety and efficacy studies in living animals prior to clinical studies. The two main approaches used are ex vivo isolated non-perfused liver models and in vivo animal models. Ex vivo non perfused models are less expensive, easier to obtain but not suitable to study the heat sink effect or experiments requiring several hours. In vivo animal models closely resemble clinical subjects but often are expensive and have small sample sizes due to ethical guidelines. Isolated perfused ex vivo liver models have been used to study drug toxicity, liver failure, organ transplantation and hepatic ablation and combine advantages of both previous models.
Fatahi, Zahra; Sadeghi, Bahman; Haghparast, Abbas
2018-01-30
The nucleus accumbens (NAc) plays a fundamental role in decision making and anticipation of reward. In addition, exogenous cannabinoids affect the behavior of humans and animals including disruption of short-term memory and cognitive impairments. Therefore, in this study, cannabinoid agonist and antagonist were administrated into the NAc to determine the effect of cannabinoid activation in the entire NAc on delay-based decision making. Rats were trained on a cost-benefit T-maze decision making task in which the animals were well-trained to choose between a small/immediate reward and a large/delay reward. After training, the animals were implanted with guide cannulae in the NAc. On test day, they received cannabinoid agonist (Win 55,212-2; 10, 50 and 100μM) and/or antagonist (AM251; 45μM) into the NAc. Percentage of high reward choice and latency of reward achievement were evaluated. Results showed that cannabinoid agonist administration caused a decrease in high reward choice such that rats selected small/immediate reward instead of large/delay reward. Moreover, in agonist-treated animals latency of reward achievement increased. Effects of cannabinoid activation on delay-based decision making with equivalent delays demonstrated that if the delay was equated on both arm goals, animals still had a preference for the high/delay reward, showing the results was not caused by an impairment of spatial preference or memory. These finding clarified that cannabinoid system activation in the entire NAc plays a critical role in the regulation of delay-based decision making. Copyright © 2017 Elsevier B.V. All rights reserved.
Mulherin, B L; Snyder, C J; Soukup, J W; Hetzel, S
2014-01-01
To determine differences in signalment between maxillomandibular (MM) and non-maxillomandibular (non-MM) trauma patients to help predict the type of injury sustained. A medical records database was searched from December 2003 to September 2012 to identify all MM trauma patients. A random sample of non-MM trauma patients was generated for comparison. Patient species, age, sex, weight, and injury aetiology were recorded for both populations. Sixty-seven MM trauma patients and 129 non-MM trauma patients were identified. Feline patients were almost twice as likely to be presented for MM trauma compared with non-MM trauma. The median weight of canine patients suffering MM injury was significantly less than that of non-MM patients (p = 0.025). A significant association existed between the causes of injuries associated with MM and non-MM trauma populations (p = 0.000023). The MM trauma patients were more likely to sustain injury as a result of an animal altercation (Bonferroni p = 0.001) while non-MM injuries were more likely to result from motor vehicle accidents (Bonferroni p = 0.001). Overall, animals that were less than one year of age with traumatic injuries were overrepresented (65/196) in comparison to the entire patient population. The results of this study may help guide clinicians in the evaluation and screening of trauma patients that are presented as an emergency. Cats, small dogs and animals suffering from animal altercations should all be closely evaluated for MM injury.
Seo, Jaehyeon; Son, Jaeman; Cho, Yeona; Park, Nohwon; Kim, Dong Wook; Kim, Jinsung; Yoon, Myonggeun
2018-04-12
Radiotherapy for the treatment of cancer in companion animals is currently administered using megavoltage X-ray machines. Because these machines are expensive, most animal hospitals do not perform radiotherapy. This study evaluated the ability of relatively inexpensive kilovoltage X-ray machines to treat companion animals. A simulation study based on a treatment planning system was performed for tumors of the brain (non-infectious meningoencephalitis), nasal cavity (malignant nasal tumors), forefoot (malignant muscular tumors), and abdomen (malignant intestinal tumors). The results of kilovoltage (300 kV and 450 kV) and megavoltage (6 MV) X-ray beams were compared. Whereas 300 kV and 6 MV X-ray beams provided optimal radiation dose homogeneity and conformity, respectively, for brain tumors, 6 MV X-rays provided optimal homogeneity and radiation conformity for nasal cavity, forefoot and abdominal tumors. Although megavoltage X-ray beams provided better radiation dose distribution in most treated animals, the differences between megavoltage and kilovoltage X-ray beams were relatively small. The similar therapeutic effects of kilovoltage and 6 MV X-ray beams suggest that kilovoltage X-ray beams may be effective alternatives to megavoltage X-ray beams in treating cancers in companion animals.
Chiba, T; Ohi, R
1998-01-01
Short-gut syndrome is likely to impair enteric fat utilization. This study was undertaken to develop a clinical test of lipid absorption without fecal collection. The absorption of enterally fed radioactive long-chain fatty acid, beta-methyl-p-(123I)-iodophenylpentadecanoic acid was investigated with continuous chyle collection in rats. The changes in excretion and time-dependent biodistribution of radioactivity of the enterally fed agent were assessed in normal control animals. Similarly, sequential urinary excretion and biodistribution were studied along with scintigraphy using sham-operated and short-gut animals. Approximately 64% of the enterally fed radioactivity was recovered in the collected chyle (24 hours). A comparison of normal control, sham-operated, and short-gut animals showed significantly less urinary and greater fecal excretions of radioactivity in short-gut animals. With the use of sequential scintigraphy, the small intestine, whole-body soft tissues, and urinary bladder were well visualized in sham-operated animals, whereas the large intestine and feces were demonstrated earlier in short-gut animals. Our results suggest that enteral feeding of the agent might be feasible for determining lipid absorption from the the dynamic changes of radioactivity in visualized abdominal organs and in urine.
Lee, Yi-Chen; Lu, Shui-Chin; Hsieh, Yu-Lin
2018-02-13
Patients with diabetes mellitus (DM) or those experiencing the neurotoxic effects of chemotherapeutic agents may develop sensation disorders due to degeneration and injury of small-diameter sensory neurons, referred to as small fiber neuropathy. Present animal models of small fiber neuropathy affect both large- and small-diameter sensory fibers and thus create a neuropathology too complex to properly assess the effects of injured small-diameter sensory fibers. Therefore, it is necessary to develop an experimental model of pure small fiber neuropathy to adequately examine these issues. This protocol describes an experimental model of small fiber neuropathy specifically affecting small-diameter sensory nerves with resiniferatoxin (RTX), an ultrapotent agonist of transient receptor potential vanilloid type 1 (TRPV1), through a single dose of intraperitoneal injection, referred to as RTX neuropathy. This RTX neuropathy showed pathological manifestations and behavioral abnormalities that mimic the clinical characteristics of patients with small fiber neuropathy, including intraepidermal nerve fiber (IENF) degeneration, specifically injury in small-diameter neurons, and induction of thermal hypoalgesia and mechanical allodynia. This protocol tested three doses of RTX (200, 50, and 10 µg/kg, respectively) and concluded that a critical dose of RTX (50 µg/kg) is required for the development of typical small fiber neuropathy manifestations, and prepared a modified immunostaining procedure to investigate IENF degeneration and neuronal soma injury. The modified procedure is fast, systematic, and economic. Behavioral evaluation of neuropathic pain is critical to reveal the function of small-diameter sensory nerves. The evaluation of mechanical thresholds in experimental rodents is particularly challenging and this protocol describes a customized metal mesh that is suitable for this type of assessment in rodents. In summary, RTX neuropathy is a new and easily established experimental model to evaluate the molecular significance and intervention underlying neuropathic pain for the development of therapeutic agents.
Frequency domain fluorescence diffuse tomography of small animals
NASA Astrophysics Data System (ADS)
Orlova, Anna G.; Turchin, Ilya V.; Kamensky, Vladislav A.; Plehanov, Vladimir I.; Balalaeva, Irina V.; Sergeeva, Ekaterina A.; Shirmanova, Marina V.; Kleshnin, Michail S.
2007-05-01
Fluorescent compounds for selective cancer cell marking are used for development of novel medical diagnostic methods, investigation of the influence of external factors on tumor growth, regress and metastasis. Only special tools for turbid media imaging, such as optical diffusion tomography permit noninvasive monitoring of fluorescent-labeled tumor alterations deep in animal tissue. In this work, the results of preliminary experiments utilizing frequency-domain fluorescent diffusion tomography (FD FDT) experimental setup in small animal are presented. Low-frequency modulated light (1 kHz) from Nd:YAG laser with second harmonic generation at the wavelength of 532 nm was used in the setup. The transilluminative planar configuration was used in the setup. A series of model experiments has been conducted and show good agreement between theoretical and experimental fluorescence intensity. Models of deep tumors were created by two methods: (1) glass capsules containing fluorophore solution were inserted into esophagus of small animals to simulate marked tumors; (2) a suspension of transfected HEΚ293-Turbo-RFP cells was subcutaneously injected to small animal. The conducted experiments have shown that FD FDT allows one to detect the presence of labeled tumor cells in small animals, to determine the volume of an experimental tumor, to perform 3D tumor reconstruction, as well as to conduct monitoring investigations. The obtained results demonstrate the potential capability of the FD FDT method for noninvasive whole-body imaging in cancer studies, diagnostics and therapy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Price, S; Yaddanapudi, S; Rangaraj, D
Purpose: Small animal irradiation can provide preclinical insights necessary for clinical advancement. In order to provide clinically relevant data, these small animal irradiations must be designed such that the treatment methods and results are comparable to clinical protocols, regardless of variations in treatment size and modality. Methods: Small animal treatments for four treatment sites (brain, liver, lung and spine) were investigated, accounting for change in treatment energy and target size. Up to five orthovoltage (300kVp) beams were used in the preclinical treatments, using circular, square, and conformal tungsten apertures, based on the treatment site. Treatments were delivered using the imagemore » guided micro irradiator (microIGRT). The plans were delivered to a mouse sized phantom and dose measurements in axial and coronal planes were performed using radiochromic film. The results of the clinical and preclinical protocols were characterized in terms of conformality number, CTV coverage, dose nonuniformity ratio, and organ at risk sparing. Results: Preclinical small animal treatment conformality was within 1–16% of clinical results for all treatment sites. The volume of the CTV receiving 100% of the prescription dose was typically within 10% of clinical values. The dose non-uniformity was consistently higher for preclinical treatments compared to clinical treatments, indicating hot spots in the target. The ratios of the mean dose in the target to the mean dose in an organ at risk were comparable if not better for preclinical versus clinical treatments. Finally, QUANTEC dose constraints were applied and the recommended morbidity limits were satisfied in each small animal treatment site. Conclusion: We have shown that for four treatment sites, preclinical 3D conformal small animal treatments can be clinically comparable if clinical protocols are followed. Using clinical protocols as the standard, preclinical irradiation methods can be altered and iteratively improved to achieve a clinically relevant irradiation model.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perks, J; Benedict, S; Lucero, S
Purpose: To document the support of radiobiological small animal research by a modern radiation oncology facility. This study confirms that a standard, human use linear accelerator can cover the range of experiments called for by researchers performing animal irradiation. A number of representative, anthropomorphic murine phantoms were made. The phantoms confirmed the small field photon and electron beams dosimetry validated the use of the linear accelerator for rodents. Methods: Laser scanning a model, CAD design and 3D printing produced the phantoms. The phantoms were weighed and CT scanned to judge their compatibility to real animals. Phantoms were produced to specificallymore » mimic lung, gut, brain, and othotopic lesion irradiations. Each phantom was irradiated with the same protocol as prescribed to the live animals. Delivered dose was measured with small field ion chambers, MOS/FETs or TLDs. Results: The density of the phantom material compared to density range across the real mice showed that the printed material would yield sufficiently accurate measurements when irradiated. The whole body, lung and gut irradiations were measured within 2% of prescribed doses with A1SL ion chamber. MOSFET measurements of electron irradiations for the orthotopic lesions allowed refinement of the measured small field output factor to better than 2% and validated the immunology experiment of irradiating one lesion and sparing another. Conclusion: Linacs are still useful tools in small animal bio-radiation research. This work demonstrated a strong role for the clinical accelerator in small animal research, facilitating standard whole body dosing as well as conformal treatments down to 1cm field. The accuracy of measured dose, was always within 5%. The electron irradiations of the phantom brain and flank tumors needed adjustment; the anthropomorphic phantoms allowed refinement of the initial output factor measurements for these fields which were made in a large block of solid water.« less
Lymph Node Metastases Optical Molecular Diagnostic and Radiation Therapy
2017-03-01
structures and not molecular functions. The one tool commonly used for metastases imaging is nuclear medicine. Positron emission tomography, PET, is...be visualized at a relevant stage., largely because most imaging is based upon structures and not molecular functions. But there are no tools to...system suitable for imaging signals from in small animals on the standard radiation therapy tools. (3) To evaluate the limits on structural , metabolic
Small prey species' behaviour and welfare: implications for veterinary professionals.
McBride, E Anne
2017-08-01
People have obligations to ensure the welfare of animals under their care. Offences under the UK Animal Welfare Act are acts, or failures of action, causing unnecessary suffering. Veterinary professionals need to be able to provide current, scientifically based prophylactic advice, and respect the limits of their expertise. The ethical concept of a life worth living and the Five Freedoms are core to welfare. Behaviour is a central component, both influencing and influenced by physical health. Owners frequently misunderstand the behaviour of small prey mammals and how to meet their needs. This review provides insight into the physical-social (external) and the cognitive-emotional (internal) environments of small prey mammals, contextualised within an evolutionary perspective. This is extrapolated to captivity and practical suggestions given for meeting behavioural freedoms and enhancing client understanding and enjoyment of their animals, thereby improving welfare. © 2017 British Small Animal Veterinary Association.
Dry coupling for whole-body small-animal photoacoustic computed tomography
NASA Astrophysics Data System (ADS)
Yeh, Chenghung; Li, Lei; Zhu, Liren; Xia, Jun; Li, Chiye; Chen, Wanyi; Garcia-Uribe, Alejandro; Maslov, Konstantin I.; Wang, Lihong V.
2017-04-01
We have enhanced photoacoustic computed tomography with dry acoustic coupling that eliminates water immersion anxiety and wrinkling of the animal and facilitates incorporating complementary modalities and procedures. The dry acoustic coupler is made of a tubular elastic membrane enclosed by a closed transparent water tank. The tubular membrane ensures water-free contact with the animal, and the closed water tank allows pressurization for animal stabilization. The dry coupler was tested using a whole-body small-animal ring-shaped photoacoustic computed tomography system. Dry coupling was found to provide image quality comparable to that of conventional water coupling.
Design and evaluation of a restraint-free small animal inhalation dosing chamber.
McConville, Jason T; Williams, Robert O; Carvalho, Thiago C; Iberg, Aimee N; Johnston, Keith P; Talbert, Robert L; Burgess, David; Peters, Jay I
2005-01-01
The aim of research was to design a small, restraint free, low stress animal dosing chamber for inhalation studies, and to investigate distribution of a model drug within the chamber. A small animal dosing chamber was designed that consisted of a polymethylmethacrylate (PMMA) airtight box (40.6 x 11.4 x 21.6 cm) with a hinged top, having a nominal wall thickness of 1.25 cm. The chamber was designed to hold up to 14 mice, each having a floor area of approximately 63 cm2, in accordance with Institutional Animal Care and Use Committee (IACUC) guidelines. A "rodent proof" distribution fan was attached to the center of the hinged closure lid. The chamber was divided into 1 inch2 zones (120 in total) to enable a profile of drug distribution within the chamber to be obtained. Small holes were drilled into the side of the chamber and sealed using Parafilm to allow access to the sampling zones. Syringes (5 mL) with appropriate length polytetrafluoroethylene (PTFE) tubing were inserted into the holes to reach the sampling zones (eight on either side of the chamber giving a total of 16 zones). An aqueous caffeine solution (2% w/v) in glycerol (25% w/v) was prepared and nebulized into the chamber using an Aeroneb Pro nebulizer. Caffeine containing droplets were circulated into the chamber at a flow rate of 1.5 L/min(-1), and the air was recirculated in a closed system for a total of 20 minutes to ensure a high concentration of caffeine droplets throughout. Following nebulization, air samples (5 mL) were withdrawn from the 16 sampling zones of the sealed chamber. The process was repeated in quadruplet until a total of 64 sampling zones had been sampled. The entire experiment was also repeated with the absence of the "rodent-proof" distribution fan. Drug concentrations were calculated from a calibration curve of caffeine using UV absorbance at 272 nm. An average mass of caffeine (Standard Deviation; S.D.) of 5.0 (4.2) mg was detected throughout the chamber when the distribution fan was fitted, and caffeine 12.6 (9.7) mg was detected without the fan. This indicated that presence of the fan caused impingement of the drug on both the chamber walls and fan components; effectively removing nebulized drug from circulation within the chamber. The distribution of drug was plotted using a 3D graph; this revealed a lower concentration at the periphery and a higher concentration in the center of the chamber both with and without the distribution fan in place. In conclusion, a humane, nonrestraint rodent dosing chamber was designed for the efficient delivery of nebulized drugs for up to 14 mice simultaneously. The highest levels of the model drug caffeine were detectable throughout the small animal dosing chamber without the distribution fan. A circulation flow rate of 1.5 L/min(-1) was found to be adequate to distribute drug in the chamber. Surprisingly, the results demonstrate that avoiding the use of a distribution fan altogether maximizes the drug concentration within the chamber by reducing impingement of the nebulized drug. The small animal, restraint-free dosing chamber represents an advancement in reproducible dosing via the pulmonary route in the small animal model. The dosing chamber may be adapted to present the lung with an almost unlimited array of compounds, encompassing drugs, toxic compounds, and even pathogens, while still maintaining a relatively stress-free microenvironment for the test subject and furthermore, total safety for the operator.
NASA Astrophysics Data System (ADS)
Ropert-Coudert, Yan; Knott, Nathan; Chiaradia, André; Kato, Akiko
2007-02-01
It is crucial in any bio-logging study to establish the potential effect that attachment of loggers may have on the animal. This ensures that the behaviour monitored by the loggers has a biological relevance, as well as for ethical reasons. Evaluation of the effects of externally attached loggers shows that they increase the drag of swimming animals and increase their energy expenditure. Nevertheless, little research has been done on the effects of size or position of such loggers. In this study, we tested whether the size (i.e. large: 4.9% versus small: 3.4% of the bird's frontal area) or the place of attachment (middle versus lower back) affected the diving behaviour of male and female little penguins ( Eudyptula minor). The positioning of the data logger on the middle or lower section of little penguins' back had little, if no effect, on the diving variables measured in this study. Size of the loggers, however, had strong effects. Birds with large loggers made shorter dives and reached shallower depths than those with small loggers. In addition, birds with large loggers made more dives probably to compensate for the extra cost of carrying a large logger. The measured variables also differed between the sexes, with males diving deeper and longer than females. Logger size had a sex-specific effect on the trip duration and descent speed, with males equipped with large loggers staying longer at sea than those with small loggers, and females with large loggers descending faster than those with small loggers. From our results, it appears that effects of logger position do not exist or are very small in comparison with the effects of logger size. The results of the current study indicate that the effects of size of loggers be evaluated more commonly in bio-logging research into the diving activity of free-ranging birds.
Jones, P H; Dawson, S; Gaskell, R M; Coyne, K P; Tierney, A; Setzkorn, C; Radford, A D; Noble, P-J M
2014-09-01
Using the Small Animal Veterinary Surveillance Network (SAVSNET), a national small animal disease-surveillance scheme, information on gastrointestinal disease was collected for a total of 76 days between 10 May 2010 and 8 August 2011 from 16,223 consultations (including data from 9115 individual dogs and 3462 individual cats) from 42 premises belonging to 19 UK veterinary practices. During that period, 7% of dogs and 3% of cats presented with diarrhoea. Adult dogs had a higher proportional morbidity of diarrhoea (PMD) than adult cats (P <0.001). This difference was not observed in animals <1 year old. Younger animals in both species had higher PMDs than adult animals (P < 0.001). Neutering was associated with reduced PMD in young male dogs. In adult dogs, miniature Schnauzers had the highest PMD. Most animals with diarrhoea (51%) presented having been ill for 2-4 days, but a history of vomiting or haemorrhagic diarrhoea was associated with a shorter time to presentation. The most common treatments employed were dietary modification (66% of dogs; 63% of cats) and antibacterials (63% of dogs; 49% of cats). There was variability in PMD between different practices. The SAVNET methodology facilitates rapid collection of cross-sectional data regarding diarrhoea, a recognised sentinel for infectious disease, and characterises data that could benchmark clinical practice and support the development of evidence-based medicine. Copyright © 2014 Elsevier Ltd. All rights reserved.
On the Utilization of Social Animals as a Model for Social Robotics
Miklósi, Ádám; Gácsi, Márta
2012-01-01
Social robotics is a thriving field in building artificial agents. The possibility to construct agents that can engage in meaningful social interaction with humans presents new challenges for engineers. In general, social robotics has been inspired primarily by psychologists with the aim of building human-like robots. Only a small subcategory of “companion robots” (also referred to as robotic pets) was built to mimic animals. In this opinion essay we argue that all social robots should be seen as companions and more conceptual emphasis should be put on the inter-specific interaction between humans and social robots. This view is underlined by the means of an ethological analysis and critical evaluation of present day companion robots. We suggest that human–animal interaction provides a rich source of knowledge for designing social robots that are able to interact with humans under a wide range of conditions. PMID:22457658
A technique for extracting blood samples from mice in fire toxicity tests
NASA Technical Reports Server (NTRS)
Bucci, T. J.; Hilado, C. J.; Lopez, M. T.
1976-01-01
The extraction of adequate blood samples from moribund and dead mice has been a problem because of the small quantity of blood in each animal and the short time available between the animals' death and coagulation of the blood. These difficulties are particularly critical in fire toxicity tests because removal of the test animals while observing proper safety precautions for personnel is time-consuming. Techniques for extracting blood samples from mice were evaluated, and a technique was developed to obtain up to 0.8 ml of blood from a single mouse after death. The technique involves rapid exposure and cutting of the posterior vena cava and accumulation of blood in the peritoneal space. Blood samples of 0.5 ml or more from individual mice have been consistently obtained as much as 16 minutes after apparent death. Results of carboxyhemoglobin analyses of blood appeared reproducible and consistent with carbon monoxide concentrations in the exposure chamber.
Retinoids and Retinal Diseases
Kiser, Philip D.; Palczewski, Krzysztof
2016-01-01
Recent progress in molecular understanding of the retinoid cycle in mammalian retina stems from painstaking biochemical reconstitution studies supported by natural or engineered animal models with known genetic lesions and studies of humans with specific genetic blinding diseases. Structural and membrane biology have been used to detect critical retinal enzymes and proteins and their substrates and ligands, placing them in a cellular context. These studies have been supplemented by analytical chemistry methods that have identified small molecules by their spectral characteristics, often in conjunction with the evaluation of models of animal retinal disease. It is from this background that rational therapeutic interventions to correct genetic defects or environmental insults are identified. Thus, most presently accepted modulators of the retinoid cycle already have demonstrated promising results in animal models of retinal degeneration. These encouraging signs indicate that some human blinding diseases can be alleviated by pharmacological interventions. PMID:27917399
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Reed F.; Hammoud, Dima A.; Lackemeyer, Matthew G.
Cowpox virus (CPXV) inoculation of nonhuman primates (NHPs) has been suggested as an alternate model for smallpox (Kramski et al., 2010, PLoS One, 5, e10412). Previously, we have demonstrated that intrabronchial inoculation of CPXV-Brighton Red (CPXV-BR) into cynomolgus monkeys resulted in a disease that shared many similarities to smallpox; however, severe respiratory tract disease was observed (Smith et al., 2011, J. Gen. Virol.). Here we describe the course of disease after small particle aerosol exposure of rhesus monkeys using computed tomography (CT) to monitor respiratory disease progression. Subjects developed a severe respiratory disease that was uniformly lethal at 5.7 log{submore » 10} PFU of CPXV-BR. CT indicated changes in lung architecture that correlated with changes in peripheral blood monocytes and peripheral oxygen saturation. While the small particle aerosol inoculation route does not accurately mimic human smallpox, the data suggest that CT can be used as a tool to monitor real-time disease progression for evaluation of animal models for human diseases. - Highlights: • Small particle aerosol exposure of rhesus results in a severe respiratory disease. • CT findings correlated with peripheral oxygen saturation and monocyte increases. • Virus dissemination was limited and mainly confined to the respiratory tract. • CT provides insight into pathogenesis to aid development of animal models of disease.« less
Ishimori, Yuu; Mitsunobu, Fumihiro; Yamaoka, Kiyonori; Tanaka, Hiroshi; Kataoka, Takahiro; Sakoda, Akihiro
2011-07-01
A radon test facility for small animals was developed in order to increase the statistical validity of differences of the biological response in various radon environments. This paper illustrates the performances of that facility, the first large-scale facility of its kind in Japan. The facility has a capability to conduct approximately 150 mouse-scale tests at the same time. The apparatus for exposing small animals to radon has six animal chamber groups with five independent cages each. Different radon concentrations in each animal chamber group are available. Because the first target of this study is to examine the in vivo behaviour of radon and its effects, the major functions to control radon and to eliminate thoron were examined experimentally. Additionally, radon progeny concentrations and their particle size distributions in the cages were also examined experimentally to be considered in future projects.
Canine obesity: is there a difference between veterinarian and owner perception?
White, G A; Hobson-West, P; Cobb, K; Craigon, J; Hammond, R; Millar, K M
2011-12-01
The overall aim of this study was to examine the nature of the relationship between dog-ownership and canine obesity, explored in two cohorts of overweight/obese or non-overweight dogs (n=125). This paper concentrates on the owners' perception of dog weight. A researcher-mediated questionnaire was used to collect data from dog owners attending a small veterinary practice. Interviewees (n=121) were asked qualitative and quantitative questions, designed to examine the owners' views of their relationship with their dogs. Although a high proportion of owners claimed to have discussed the dog's weight with their veterinarian, some discrepancies were apparent between owner perception of animal weight and the veterinarian's evaluation of body condition score. Owner disagreement was significantly greater for the veterinarian-defined overweight dogs (P=0·005). Owners often provide personal narratives to account for their dog's weight status. This study confirms the important role of the vet in providing information about the issue of dog weight but also suggests that providing verbal information is sometimes insufficient. The study also indicates the potential value of qualitative research methods to further understand client perception of complex animal care issues and highlights the need for further in-depth research. © 2011 British Small Animal Veterinary Association.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zamora, P.O.; Bender, H.; Biersack, H.J.
1995-07-01
The purpose of this study was to evaluate the therapeutic efficacy of Re-188-RC-160 in experimental models of human small cell lung carcinomas which mimic the clinical presentation. In the experimental model, cells from the human small cell lung carcinoma cell line NCI-H69 cells were inoculated into the thoracic cavity of athymic mice and rats. Subsequently, the biodistribution of Re-188-RC-160 after injection into the pleural cavity, a radiolabeled somatostatin analogue, was monitored as was the effect on the subsequent growth of tumors. The results presented here, and which are a part of a larger series of studies, suggest that Re-188-RC-160 canmore » be effectively used in this animal model to restrict the growth of small cell lung carcinoma in the thoracic cavity.« less
Medina, M; Collins, A G; Silberman, J D; Sogin, M L
2001-08-14
We studied the evolutionary relationships among basal metazoan lineages by using complete large subunit (LSU) and small subunit (SSU) ribosomal RNA sequences for 23 taxa. After identifying competing hypotheses, we performed maximum likelihood searches for trees conforming to each hypothesis. Kishino-Hasegawa tests were used to determine whether the data (LSU, SSU, and combined) reject any of the competing hypotheses. We also conducted unconstrained tree searches, compared the resulting topologies, and calculated bootstrap indices. Shimodaira-Hasegawa tests were applied to determine whether the data reject any of the topologies resulting from the constrained and unconstrained tree searches. LSU, SSU, and the combined data strongly contradict two assertions pertaining to sponge phylogeny. Hexactinellid sponges are not likely to be the basal lineage of a monophyletic Porifera or the sister group to all other animals. Instead, Hexactinellida and Demospongia form a well-supported clade of siliceous sponges, Silicea. It remains unclear, on the basis of these data alone, whether the calcarean sponges are more closely related to Silicea or to nonsponge animals. The SSU and combined data reject the hypothesis that Bilateria is more closely related to Ctenophora than it is to Cnidaria, whereas LSU data alone do not refute either hypothesis. LSU and SSU data agree in supporting the monophyly of Bilateria, Cnidaria, Ctenophora, and Metazoa. LSU sequence data reveal phylogenetic structure in a data set with limited taxon sampling. Continued accumulation of LSU sequences should increase our understanding of animal phylogeny.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Medina, Monica; Collins, Allen G.; Silberman, Jeffrey
2001-06-21
We studied the evolutionary relationships among basal metazoan lineages by using complete large subunit (LSU) and small subunit (SSU) ribosomal RNA sequences for 23 taxa. After identifying competing hypotheses, we performed maximum likelihood searches for trees conforming to each hypothesis. Kishino-Hasegawa tests were used to determine whether the data (LSU, SSU, and combined) reject any of the competing hypotheses. We also conducted unconstrained tree searches, compared the resulting topologies, and calculated bootstrap indices. Shimodaira-Hasegawa tests were applied to determine whether the data reject any of the topologies resulting from the constrained and unconstrained tree searches. LSU, SSU, and the combinedmore » data strongly contradict two assertions pertaining to sponge phylogeny. Hexactinellid sponges are not likely to be the basal lineage of amonophyletic Porifera or the sister group to all other animals. Instead, Hexactinellida and Demospongia form a well-supported clade of siliceous sponges, Silicea. It remains unclear, on the basis of these data alone, whether the calcarean sponges are more closely related to Silicea or to nonsponge animals. The SSU and combined data reject the hypothesis that Bilateria is more closely related to Ctenophora than it is to Cnidaria, whereas LSU data alone do not refute either hypothesis. LSU and SSU data agree in supporting the monophyly of Bilateria, Cnidaria, Ctenophora, and Metazoa. LSU sequence data reveal phylogenetic structure in a data set with limited taxon sampling. Continued accumulation of LSU sequences should increase our understanding of animal phylogeny.« less
Silvopasture: Small ruminants for establishment, management and usage
USDA-ARS?s Scientific Manuscript database
Small farm pastures, hayfields, and woodlots are very productive in terms of forage, animal and wood products. Inherent livestock production capability can be improved through better herbage and animal management. Woodlot management can increase economic return, species diversity, and farm aesthetic...
Bio-medical telemetry: Sensing and transmitting biological information from animals to man
NASA Technical Reports Server (NTRS)
Mackay, S.
1971-01-01
The application of small radio transmitters for monitoring biological activity in animals and humans is discussed. The microminiaturization of the electronic transmitters makes it possible for them to be swallowed and to operate within the body with no external connections. The small size also makes it possible for the transmitters to be surgically implanted or carried externally to monitor specific bodily functions. The use of satellites to monitor the activity of birds and animals carrying small transmitters is described. Photographs of birds, fish, and reptiles which were equipped with miniature electronic monitors are provided.
Image quality phantom and parameters for high spatial resolution small-animal SPECT
NASA Astrophysics Data System (ADS)
Visser, Eric P.; Harteveld, Anita A.; Meeuwis, Antoi P. W.; Disselhorst, Jonathan A.; Beekman, Freek J.; Oyen, Wim J. G.; Boerman, Otto C.
2011-10-01
At present, generally accepted standards to characterize small-animal single photon emission tomographs (SPECT) do not exist. Whereas for small-animal positron emission tomography (PET), the NEMA NU 4-2008 guidelines are available, such standards are still lacking for small-animal SPECT. More specifically, a dedicated image quality (IQ) phantom and corresponding IQ parameters are absent. The structures of the existing PET IQ phantom are too large to fully characterize the sub-millimeter spatial resolution of modern multi-pinhole SPECT scanners, and its diameter will not fit into all scanners when operating in high spatial resolution mode. We therefore designed and constructed an adapted IQ phantom with smaller internal structures and external diameter, and a facility to guarantee complete filling of the smallest rods. The associated IQ parameters were adapted from NEMA NU 4. An additional parameter, effective whole-body sensitivity, was defined since this was considered relevant in view of the variable size of the field of view and the use of multiple bed positions as encountered in modern small-animal SPECT scanners. The usefulness of the phantom was demonstrated for 99mTc in a USPECT-II scanner operated in whole-body scanning mode using a multi-pinhole mouse collimator with 0.6 mm pinhole diameter.
A cross-sectional study of small mammals for tick-borne pathogen infection in northern Mongolia.
Pulscher, Laura A; Moore, Thomas C; Caddell, Luke; Sukhbaatar, Lkhagvatseren; von Fricken, Michael E; Anderson, Benjamin D; Gonchigoo, Battsetseg; Gray, Gregory C
2018-01-01
Background : Tick-borne pathogens (TBPs) are frequently studied in developed nations but are often neglected in emerging countries. In Mongolia, TBP research is especially sparse, with few research reports focusing upon human and domestic animal disease and tick ecology. However, little information exists on TBPs in small mammals. Methods : In this 2016 cross-sectional pilot study, we sought to uniquely study wildlife for TBPs. We live-trapped small mammals, and tested their whole blood, serum and ear biopsy samples for molecular or serological evidence of Borrelia spp., Rickettsia spp., and Anaplasma spp. /Ehrlichia spp. Results : Of 64 small mammals collected, 56.0%, 39.0% and 0.0% of animals were positive by molecular assays for Borrelia spp., Rickettsia spp., and Anaplasma spp. /Erhlicia spp., respectively. 41.9% were seropositive for A. phagocytophilum and 24.2% of animals were seropositive for Rickettsia rickettsii . Conclusion : This pilot data demonstrates evidence of a number of TBPs among small mammal populations in northern Mongolia and suggests the need to further investigate what role these mammals play in human and domestic animal disease.
Companion animals and well-being in palliative care nursing: a literature review.
MacDonald, Julie M; Barrett, David
2016-02-01
To evaluate and critique current knowledge regarding the role of animals in palliative care. To explore the impact that animals may have on the well-being of individuals and to identify gaps in the evidence base. There is recognition that having a companion animal will affect patient experience. Similarly, there has been some previous exploration on the use of specific animal assisted therapies for patients with different healthcare needs. A literature review was conducted to identify published and unpublished research about companion animals or animal-assisted therapy in palliative and/or end-of-life care. The primary objective was to explore the impact of animals on well-being at the end of life. A search for literature was carried out using a variety of databases and different combinations of search terms linked to animals in palliative care. Included works were critically appraised and thematically analysed. A limited range of literature was identified. From the small number of studies included in the review (n = 4), it appears that there is some evidence of animals (either companion animals or those used specifically to enhance care) having a positive impact on the patient experience. This study suggests that animals play a large part in the lives of people receiving palliative care. Using animals to support care may also offer some benefits to the patient experience. However, there appears to be a dearth of high-quality literature in this area. More research is therefore required. Nurses providing palliative care need to be aware of the part that a companion animal may play in the life of patients. There may also be the opportunity for nurses in some settings to integrate animal therapy into their provision of palliative care. © 2015 John Wiley & Sons Ltd.
Quantification of mouse in vivo whole-body vibration amplitude from motion-blur using x-ray imaging.
Hu, Zhengyi; Welch, Ian; Yuan, Xunhua; Pollmann, Steven I; Nikolov, Hristo N; Holdsworth, David W
2015-08-21
Musculoskeletal effects of whole-body vibration on animals and humans have become an intensely studied topic recently, due to the potential of applying this method as a non-pharmacological therapy for strengthening bones. It is relatively easy to quantify the transmission of whole-body mechanical vibration through the human skeletal system using accelerometers. However, this is not the case for small-animal pre-clinical studies because currently available accelerometers have a large mass, relative to the mass of the animals, which causes the accelerometers themselves to affect the way vibration is transmitted. Additionally, live animals do not typically remain motionless for long periods, unless they are anesthetized, and they are required to maintain a static standing posture during these studies. These challenges provide the motivation for the development of a method to quantify vibrational transmission in small animals. We present a novel imaging technique to quantify whole-body vibration transmission in small animals using 280 μm diameter tungsten carbide beads implanted into the hind limbs of mice. Employing time-exposure digital x-ray imaging, vibrational amplitude is quantified based on the blurring of the implanted beads caused by the vibrational motion. Our in vivo results have shown this technique is capable of measuring vibration amplitudes as small as 0.1 mm, with precision as small as ±10 μm, allowing us to distinguish differences in the transmitted vibration at different locations on the hindlimbs of mice.
Quantification of mouse in vivo whole-body vibration amplitude from motion-blur using x-ray imaging
NASA Astrophysics Data System (ADS)
Hu, Zhengyi; Welch, Ian; Yuan, Xunhua; Pollmann, Steven I.; Nikolov, Hristo N.; Holdsworth, David W.
2015-08-01
Musculoskeletal effects of whole-body vibration on animals and humans have become an intensely studied topic recently, due to the potential of applying this method as a non-pharmacological therapy for strengthening bones. It is relatively easy to quantify the transmission of whole-body mechanical vibration through the human skeletal system using accelerometers. However, this is not the case for small-animal pre-clinical studies because currently available accelerometers have a large mass, relative to the mass of the animals, which causes the accelerometers themselves to affect the way vibration is transmitted. Additionally, live animals do not typically remain motionless for long periods, unless they are anesthetized, and they are required to maintain a static standing posture during these studies. These challenges provide the motivation for the development of a method to quantify vibrational transmission in small animals. We present a novel imaging technique to quantify whole-body vibration transmission in small animals using 280 μm diameter tungsten carbide beads implanted into the hind limbs of mice. Employing time-exposure digital x-ray imaging, vibrational amplitude is quantified based on the blurring of the implanted beads caused by the vibrational motion. Our in vivo results have shown this technique is capable of measuring vibration amplitudes as small as 0.1 mm, with precision as small as ±10 μm, allowing us to distinguish differences in the transmitted vibration at different locations on the hindlimbs of mice.
UTIs in small animal patients: part 1: etiology and pathogenesis.
Smee, Nicole; Loyd, Kimberly; Grauer, Greg
2013-01-01
Understanding how urinary tract infections (UTIs) can occur and how to classify them can help the practitioner to make a plan for treatment. This review summarizes the etiology, pathogenesis, and host defense mechanisms associated with bacterial UTIs in dogs and cats. UTIs in Small Animal Patients: Part 2: Diagnosis, Treatment, and Complications will appear in the March/April 2013 issue of the Journal of the American Animal Hospital Association.
Fluorescence diffuse tomography for detection of RFP-expressed tumors in small animals
NASA Astrophysics Data System (ADS)
Turchin, Ilya V.; Savitsky, Alexander P.; Kamensky, Vladislav A.; Plehanov, Vladimir I.; Orlova, Anna G.; Kleshnin, Mikhail S.; Shirmanova, Marina V.; Fix, Ilya I.; Popov, Vladimir O.
2007-07-01
Capabilities of tumor detection by different optical methods can be significantly improved by labeling of tumors with fluorescent markers. Creation of tumor cell lines transfected with fluorescent proteins provides the possibility not only to detect tumor, but also to conduct the intravital monitoring studies. Cell lines of human melanomas Mel-P, Mel-Kor and human embryonic kidney HEK-293 Phoenix were transfected with DsRed-Express and Turbo-RFP genes. Emission of RFP in the long-wave optical range permits detection of the deeply located tumors, which is essential for whole-body imaging. Only special tools for turbid media imaging, such as fluorescent diffusion tomography (FDT), enable noninvasive investigation of the internal structure of biological tissue. FDT setup for monitoring of tumor growth in small animals has been created. An animal is scanned in the transilluminative configuration by low-frequency modulated light (1 kHz) from Nd:YAG laser with second harmonic generation at the 532 nm wavelength. An optimizing algorithm for scanning of an experimantal animal is suggested. In vivo experiments were conducted immediately after the subcutaneously injection of fluorescing cells into small animals. It was shown that FDT method allows to detect the presence of fluorescent cells in small animals and can be used for monitoring of tumor growth and anticancer drug responce.
Performance evaluation of the Trans-PET® BioCaliburn® LH system: a large FOV small-animal PET system
NASA Astrophysics Data System (ADS)
Wang, Luyao; Zhu, Jun; Liang, Xiao; Niu, Ming; Wu, Xiaoke; Kao, Chien-Min; Kim, Heejong; Xie, Qingguo
2015-01-01
The Trans-PET® BioCaliburn® LH is a commercial positron emission tomography (PET) system for animal imaging. The system offers a large transaxial field-of-view (FOV) of 13.0 cm to allow imaging of multiple rodents or larger animals. This paper evaluates and reports the performance characteristics of this system. Methods: in this paper, the system was evaluated for its spatial resolutions, sensitivity, scatter fraction, count rate performance and image quality in accordance with the National Electrical Manufacturers Association (NEMA) NU-4 2008 specification with modifications. Phantoms and animals not specified in the NEMA specification were also scanned to provide further demonstration of its imaging capability. Results: the spatial resolution is 1.0 mm at the center. When using a 350-650 keV energy window and a 5 ns coincidence time window, the sensitivity at the center is 2.04%. The noise equivalent count-rate curve reaches a peak value of 62 kcps at 28 MBq for the mouse-sized phantom and a peak value of 25 kcps at 31 MBq for the rat-sized phantom. The scatter fractions are 8.4% and 17.7% for the mouse- and rat-sized phantoms, respectively. The uniformity and recovery coefficients measured by using the NEMA image-quality phantom both indicate good imaging performance, even though the reconstruction algorithm provided by the vendor does not implement all desired corrections. The Derenzo-phantom images show that the system can resolve 1.0 mm diameter rods. Animal studies demonstrate the capabilities of the system in dynamic imaging and to image multiple rodents. Conclusion: the Trans-PET® BioCaliburn® LH system offers high spatial resolution, a large transaixal FOV and adequate sensitivity. It produces animal images of good quality and supports dynamic imaging. The system is an attractive imaging technology for preclinical research.
Lead accumulation in woodchucks (Marmota monax) at small arms and skeet ranges.
Johnson, Mark S; Major, Michael A; Casteel, Stan W
2004-10-01
Increasing concern regarding the stewardship of US Army lands requires a proactive program to evaluate sites of potential risk. Small arms and upland skeet ranges are a potentially significant source of lead exposure for burrowing mammals. Woodchucks (Marmota monax) were evaluated for lead exposure in a previously used upland skeet range and a small arms range, respective to animals collected at two nearby reference locations. Soil lead concentrations collected at burrow entrances on the firing ranges were compared with blood, bone, kidney, liver, and fecal concentrations of woodchucks collected from the reference areas. No statistical differences were found in the lead concentrations in tissue between woodchucks in reference and firing ranges; concentrations of lead in liver and kidney were below detection limits. Levels in bone, blood, and feces suggest the bioavailability of lead at these various sites, although other factors (e.g., differences in foraging areas, age structure, habitat preferences, and environmental conditions) were also likely to influence exposure. Blood levels were below that which suggests toxicity. Further analysis of other ranges with higher lead concentrations and of small mammal species with smaller home ranges is recommended to further elucidate trends that could be extrapolated to other sites.
Molecular Imaging of Experimental Abdominal Aortic Aneurysms
Ramaswamy, Aneesh K.; Hamilton, Mark; Joshi, Rucha V.; Kline, Benjamin P.; Li, Rui; Wang, Pu; Goergen, Craig J.
2013-01-01
Current laboratory research in the field of abdominal aortic aneurysm (AAA) disease often utilizes small animal experimental models induced by genetic manipulation or chemical application. This has led to the use and development of multiple high-resolution molecular imaging modalities capable of tracking disease progression, quantifying the role of inflammation, and evaluating the effects of potential therapeutics. In vivo imaging reduces the number of research animals used, provides molecular and cellular information, and allows for longitudinal studies, a necessity when tracking vessel expansion in a single animal. This review outlines developments of both established and emerging molecular imaging techniques used to study AAA disease. Beyond the typical modalities used for anatomical imaging, which include ultrasound (US) and computed tomography (CT), previous molecular imaging efforts have used magnetic resonance (MR), near-infrared fluorescence (NIRF), bioluminescence, single-photon emission computed tomography (SPECT), and positron emission tomography (PET). Mouse and rat AAA models will hopefully provide insight into potential disease mechanisms, and the development of advanced molecular imaging techniques, if clinically useful, may have translational potential. These efforts could help improve the management of aneurysms and better evaluate the therapeutic potential of new treatments for human AAA disease. PMID:23737735
IFRD1 Is a Candidate Gene for SMNA on Chromosome 7q22-q23
Brkanac, Zoran; Spencer, David; Shendure, Jay; Robertson, Peggy D.; Matsushita, Mark; Vu, Tiffany; Bird, Thomas D.; Olson, Maynard V.; Raskind, Wendy H.
2009-01-01
We have established strong linkage evidence that supports mapping autosomal-dominant sensory/motor neuropathy with ataxia (SMNA) to chromosome 7q22-q32. SMNA is a rare neurological disorder whose phenotype encompasses both the central and the peripheral nervous system. In order to identify a gene responsible for SMNA, we have undertaken a comprehensive genomic evaluation of the region of linkage, including evaluation for repeat expansion and small deletions or duplications, capillary sequencing of candidate genes, and massively parallel sequencing of all coding exons. We excluded repeat expansion and small deletions or duplications as causative, and through microarray-based hybrid capture and massively parallel short-read sequencing, we identified a nonsynonymous variant in the human interferon-related developmental regulator gene 1 (IFRD1) as a disease-causing candidate. Sequence conservation, animal models, and protein structure evaluation support the involvement of IFRD1 in SMNA. Mutation analysis of IFRD1 in additional patients with similar phenotypes is needed for demonstration of causality and further evaluation of its importance in neurological diseases. PMID:19409521
Bartholomä, Mark D; He, Huamei; Pacak, Christina A; Dunning, Patricia; Fahey, Frederic H; McGowan, Francis X; Cowan, Douglas B; Treves, S Ted; Packard, Alan B
2013-11-01
Myocardial infarction is the leading cause of death in western countries, and positron emission tomography (PET) plays an increasing role in the diagnosis and treatment planning for this disease. However, the absence of an (18)F-labeled PET myocardial perfusion tracer hampers the widespread use of PET in myocardial perfusion imaging (MPI). We recently reported a potential MPI agent based on (18)F-labeled rhodamine B. The goal of this study was to more completely define the biological properties of (18)F-labeled rhodamine B with respect to uptake and localization in an animal model of myocardial infarction and to evaluate the uptake (18)F-labeled rhodamine B by cardiomyocytes. A total of 12 female Sprague Dawley rats with a permanent ligation of the left anterior descending artery (LAD) were studied with small-animal PET. The animals were injected with 100-150 μCi of (18)F-labeled rhodamine B diethylene glycol ester ([(18)F]RhoBDEGF) and imaged two days before ligation. The animals were imaged again two to ten days post-ligation. After the post-surgery scans, the animals were euthanized and the hearts were sectioned into 1mm slices and myocardial infarct size was determined by phosphorimaging and 2,3,5-triphenyltetrazolium chloride staining (TTC). In addition, the uptake of [(18)F]RhoBDEGF in isolated rat neonatal cardiomyocytes was determined by fluorescence microscopy. Small-animal PET showed intense and uniform uptake of [(18)F]RhoBDEGF throughout the myocardium in healthy rats. After LAD ligation, well defined perfusion defects were observed in the PET images. The defect size was highly correlated with the infarct size as determined ex vivo by phosphorimaging and TTC staining. In vitro, [(18)F]RhoBDEGF was rapidly internalized into rat cardiomyocytes with ~40 % of the initial activity internalized within the 60 min incubation time. Fluorescence microscopy clearly demonstrated localization of [(18)F]RhoBDEGF in the mitochondria of rat cardiomyocytes. Fluorine-18-labeled rhodamine B diethylene glycol ester ([(18)F]RhoBDEGF) provides excellent image quality and clear delineation of myocardial infarcts in a rat infarct model. In vitro studies demonstrate localization of the tracer in the mitochondria of cardiac myocytes. In combination, these results support the continued evaluation of this tracer for the PET assessment of myocardial perfusion. © 2013.
Bartholomä, Mark D.; He, Huamei; Pacak, Christina; Dunning, Patricia; Fahey, Frederic H.; McGowan, Francis; Cowan, Douglas; Treves, S. Ted; Packard, Alan B.
2013-01-01
Introduction Myocardial infarction is the leading cause of death in western countries, and positron emission tomography (PET) plays an increasing role in the diagnosis and treatment planning for this disease. However, the absence of an F-18-labeled PET myocardial perfusion tracer hampers the widespread use of PET in myocardial perfusion imaging (MPI). We recently reported a potential MPI agent based on F-18-labeled rhodamine B. The goal of this study was to more completely define the biological properties of F-18-labeled rhodamine B with respect to uptake and localization in an animal model of myocardial infarction and to evaluate the uptake F-18-labeled rhodamine B by cardiomyocytes. Methods A total of 12 female Sprague Dawley rats with a permanent ligation of the left anterior descending artery (LAD) were studied with small-animal PET. The animals were injected with 100–150 µCi of F-18-labeled rhodamine B diethylene glycol ester ([18F]RhoBDEGF) and imaged two days before ligation. The animals were imaged again two to ten days post-ligation. After the post-surgery scans, the animals were euthanized and the hearts were sectioned into 1 mm slices and myocardial infarct size was determined by phosphorimaging and 2,3,5-triphenyltetrazolium chloride staining (TTC). In addition, the uptake of [18F]RhoBDEGF in isolated rat neonatal cardiomyocytes was determined by fluorescence microscopy. Results Small-animal PET showed intense and uniform uptake of [18F]RhoBDEGF throughout the myocardium in healthy rats. After LAD ligation, well defined perfusion defects were observed in the PET images. The defect size was highly correlated with the infarct size as determined ex vivo by phosphorimaging and TTC staining. In vitro, [18F]RhoBDEGF was rapidly internalized into rat cardiomyocytes with ~40 % of the initial activity internalized within the 60 min incubation time. Fluorescence microscopy clearly demonstrated localization of [18F]RhoBDEGF in the mitochondria of rat cardiomyocytes. Conclusion Fluorine-18-labeled rhodamine B diethylene glycol ester ([18F]RhoBDEGF) provides excellent image quality and clear delineation of myocardial infarcts in a rat infarct model. In vitro studies demonstrate localization of the tracer in the mitochondria of cardiac myocytes. In combination, these results support the continued evaluation of this tracer for the PET assessment of myocardial perfusion. PMID:24011396
The present and future of opioid analgesics in small animal practice.
Simon, B T; Steagall, P V
2017-08-01
Opioids are the cornerstone for the treatment of acute pain in small animal patients. This is primarily because of their remarkable safety profile, high efficacy, and benefit of reversibility. There have been some significant advances in our knowledge on opioid pharmacology and clinical usage in companion animal medicine. This review discusses the progression of opioid use in small animal practice providing current misconceptions and controversies in light of routes of administration. Potential targets for research and drug development and novel therapies are discussed in addition to the concepts of glial cell modulators, individual variability, and opioid tolerance and hyperalgesia. The future brings an interesting perspective with the application of pharmacogenetics and individualized pain management in canine and feline practice. © 2016 John Wiley & Sons Ltd.
Development of a high-sensitivity BGO well counter for small animal PET studies.
Yamamoto, Seiichi; Watabe, Hiroshi; Kanai, Yasukazu; Watabe, Tadashi; Imaizumi, Masao; Shimosegawa, Eku; Hatazawa, Jun
2012-01-01
In quantitative measurements of small animal PET studies, blood sampling is limited due to the small amounts of blood such animals can provide. In addition, injection doses are quite limited. In this situation, a high-sensitivity well counter would be useful for reducing the amount of the blood sample needed from small animals. Bismuth germinate (BGO) has a high stopping power for high-energy gamma rays compared to NaI(Tl), which is commonly used for conventional well counters. We have developed a BGO well counter and have tested it for blood-sampling measurements in small animals. The BGO well counter uses a square BGO block (59 × 59 × 50 mm) with a square open space (27 × 27 × 34 mm) in the center of the block. The BGO block was optically coupled to a 59-mm square-shaped photomultiplier tube (PMT). Signals from the PMT were digitally processed for the integration and energy window setting. The results showed that the energy spectrum of the BGO well counter measured with a Na-22 point source provided counts that were about 6 times higher for a 1022-keV (511 keV × 2) gamma peak than the spectrum of a 2-in. NaI(Tl) well counter. The relative sensitivity of the developed BGO well counter was 3.4 times higher than that of a NaI(Tl) well counter. The time activity curve of arterial blood was obtained successfully with the BGO well counter for a F-18-FDG study on rat. The BGO well counter will contribute to reducing the amount of sampled blood and to improving the throughput of quantitative measurements in small animal PET studies.
Frelin-Labalme, Anne-Marie; Ledoux, Xavier
2017-01-01
Objective: Small animal image-guided irradiators have recently been developed to mimic the delivery techniques of clinical radiotherapy. A dosemeter adapted to millimetric beams of medium-energy X-rays is then required. This work presents the characterization of a dosemeter prototype for this particular application. Methods: A scintillating optical fibre dosemeter (called DosiRat) has been implemented to perform real-time dose measurements with the dedicated small animal X-RAD® 225Cx (Precision X-Ray, Inc., North Branford, CT) irradiator. Its sensitivity, stem effect, stability, linearity and measurement precision were determined in large field conditions for three different beam qualities, consistent with small animal irradiation and imaging parameters. Results: DosiRat demonstrates good sensitivity and stability; excellent air kerma and air kerma rate linearity; and a good repeatability for air kerma rates >1 mGy s−1. The stem effect was found to be negligible. DosiRat showed limited precision for low air kerma rate measurements (<1 mGy s−1), typically for imaging protocols. A positive energy dependence was found that can be accounted for by calibrating the dosemeter at the needed beam qualities. Conclusion: The dosimetric performances of DosiRat are very promising. Extensive studies of DosiRat energy dependence are still required. Further developments will allow to reduce the dosemeter size to ensure millimetric beams dosimetry and perform small animal in vivo dosimetry. Advances in knowledge: Among existing point dosemeters, very few are dedicated to both medium-energy X-rays and millimetric beams. Our work demonstrated that scintillating fibre dosemeters are suitable and promising tools for real-time dose measurements in the small animal field of interest. PMID:27556813
Synchrotron radiation microimaging in rabbit models of cancer for preclinical testing
NASA Astrophysics Data System (ADS)
Umetani, Keiji; Uesugi, Kentaro; Kobatake, Makito; Yamamoto, Akira; Yamashita, Takenori; Imai, Shigeki
2009-10-01
Preclinical laboratory animal imaging modalities such as microangiography and micro-computed tomography (micro-CT) have been developed at the SPring-8 BL20B2 bending magnet beamline. The objective of this paper is to demonstrate the usefulness of microangiography systems for physiological examinations of live animals and micro-CT systems for postmortem morphological examinations. Synchrotron radiation microangiography and micro-CT with contrast agents present the main advantageous capability of depicting the anatomy of small blood vessels with tens of micrometers' diameter. This paper reports two imaging instrument types and their respective applications to preclinical imaging of tumor angiogenic blood vessels in tumor-bearing rabbits, where tumor angiogenesis is characterized morphologically by an increased number of blood vessels. A microangiography system with spatial resolution around 10 μm has been used for therapeutically evaluating angiogenic vessels in a rabbit model of cancer for evaluating embolization materials in transcatheter arterial embolization and for radiation therapy. After an iodine contrast agent was injected into an artery, in vivo imaging was carried out using a high-resolution real-time detector incorporating an X-ray direct-conversion-type SATICON pickup tube. On the other hand, a micro-CT system capably performed three-dimensional visualization of tumor angiogenic blood vessels using tumor-transplanted rabbit specimens with a barium sulfate contrast agent injected into the blood vessels. For specimen imaging, a large-field high-resolution micro-CT system based on a 10-megapixel CCD camera was developed to study tumor-associated alterations in angioarchitecture. Evidence of increased vascularity by tumor angiogenesis and decreased vascularity by tumor treatments was achieved by physiological evaluation of angiogenic small blood vessels in microangiographic imaging and by morphological assessment in micro-CT imaging. These results demonstrate the accuracy and usefulness of microangiography and micro-CT systems for quantitative examination of animals' angioarchitecture, respectively, during live and postmortem examinations.
2014-09-30
TERM GOALS We recently developed small satellite-linked telemetry tags that are anchored with small attachment darts to the dorsal fins of small ...monitor the movements of numerous species not previously accessible because they were too large or difficult to capture safely, but too small for tags...cetaceans that provides the data needed to answer critical conservation and management questions without an adverse effect on the tagged animal. Therefore
Liu, Jingfei; Foiret, Josquin; Stephens, Douglas N.; Le Baron, Olivier; Ferrara, Katherine W.
2016-01-01
A 1.5 MHz prolate spheroidal therapeutic array with 128 circular elements was designed to accommodate standard imaging arrays for ultrasonic image-guided hyperthermia. The implementation of this dual-array system integrates real-time therapeutic and imaging functions with a single ultrasound system (Vantage 256, Verasonics). To facilitate applications involving small animal imaging and therapy the array was designed to have a beam depth of field smaller than 3.5 mm and to electronically steer over distances greater than 1 cm in both the axial and lateral directions. In order to achieve the required f number of 0.69, 1-3 piezocomposite modules were mated within the transducer housing. The performance of the prototype array was experimentally evaluated with excellent agreement with numerical simulation. A focal volume (2.70 mm (axial) × 0.65 mm (transverse) × 0.35 mm (transverse)) defined by the −6 dB focal intensity was obtained to address the dimensions needed for small animal therapy. An electronic beam steering range defined by the −3 dB focal peak intensity (17 mm (axial) × 14 mm (transverse) × 12 mm (transverse)) and −8 dB lateral grating lobes (24 mm (axial) × 18 mm (transverse) × 16 mm (transverse)) was achieved. The combined testing of imaging and therapeutic functions confirmed well-controlled local heating generation and imaging in a tissue mimicking phantom. This dual-array implementation offers a practical means to achieve hyperthermia and ablation in small animal models and can be incorporated within protocols for ultrasound-mediated drug delivery. PMID:27353347
Effect of National Football League games on small animal emergency room caseload.
Rozanski, Elizabeth A; Rondeau, Mark P; Shaw, Scott P; Rush, John E
2009-07-01
To evaluate whether games of popular professional football teams have an effect on small animal emergency room caseload and percentage of dogs and cats that subsequently are hospitalized, are euthanatized, or die following admission to veterinary emergency rooms located within a dedicated fan base. Prospective study. 818 dogs and cats admitted to the emergency room. During the 2007 New England Patriots (NEP) football season, small animal emergency room caseload was recorded for Sunday (4-hour blocks, 8:00 AM until 12:00 midnight) and Monday night (7:00 PM to 11:00 PM). Number of dogs and cats that subsequently were hospitalized, died, or were euthanatized was recorded. Mean game importance rating (GIR) was determined for NEP games (scale, 1 [mild] to 3 [great]). Percentage of dogs and cats admitted from 12:00 noon to 4:00 PM on Sundays during NEP games (mean GIR, 1.7) versus non-NEP games was not different. Mean +/- SD percentage of dogs and cats admitted from 4:00 PM to 8:00 PM on Sundays during NEP games (mean GIR, 2.4) versus non-NEP games was significantly different (18 +/- 5% and 25 +/- 7% of daily caseload, respectively). Percentage of dogs and cats admitted from 8:00 PM to 12:00 midnight on Sundays during NEP games (mean GIR, 2.1) versus non-NEP games was not different. Game type (NEP vs non-NEP) during emergency room admission did not influence whether dogs and cats subsequently were hospitalized, died, or were euthanatized. Professional sporting events may influence veterinary emergency room caseloads.
Engelskirchen, Simon; Ehlers, Jan; Kirk, Ansgar T; Tipold, Andrea; Dilly, Marc
2017-09-20
During five and a half years of studying veterinary medicine, students should in addition to theoretical knowledge acquire sufficient practical skills. Considering animal welfare and ethical aspects, opportunities for hands-on learning on living animals are limited because of the high annual number of students. The first German veterinary clinical-skills lab, established in 2013 at the University for Veterinary Medicine Hannover, Foundation (TiHo), offers opportunities for all students to learn, train and repeat clinical skills on simulators and models as frequently as they would like, until they feel sufficiently confident to transfer these skills to living animals. This study describes the establishment of clinical-skills lab training within the students' practical education, using the example of the small-animal clinic of the TiHo. Two groups of students were compared: without skills lab training (control group K) and with skills lab training (intervention group I). At the end of both the training and a subsequent 10-week clinical rotation in different sections of the clinic, an objective structured clinical examination (OSCE) was performed, testing the students' practical skills at 15 stations. An additional multiple-choice test was performed before and after the clinical rotation to evaluate the increased theoretical knowledge. Students of group I achieved significantly (p ≤ 0.05) better results in eight of the 15 tested skills. The multiple-choice test revealed a significant (p ≤ 0.05) gain of theoretical knowledge in both groups without any differences between the groups. Students displayed a high degree of acceptance of the skills lab training. Using simulators and models in veterinary education is an efficient teaching concept, and should be used continually and integrated in the curriculum.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cline, J.F.; Burton, F.G.; Cataldo, D.A.
1982-09-01
The objective of this project was to develop and evaluate the effectiveness of physical and chemical barriers designed to prevent plant and animal breachment of uranium mill tailings containment systems for an extended period of time. A polymeric carrier/biocide delivery system was developed and tested in the laboratory, greenhouse and field. A continuous flow technique was established to determine the release rates of the biocides from the PCD systems; polymeric carrier specifications were established. Studies were conducted to determine effective biocide concentrations required to produce a phytotoxic response and the relative rates of phytotoxin degradation resulting from chemical and biologicalmore » breakdown in soils. The final PCD system developed was a pelletized system containing 24% trifluralin, 18% carbon black and 58% polymer. Pellets were placed in the soil at the Grand Junction U-tailings site at one in. and two in. intervals. Data obtained in the field determined that the pellets released enough herbicide to the soil layer to stop root elongation past the barrier. Physical barriers to subsurface movement of burrowing animals were investigated. Small crushed stone (1 to 1 1/2 in. diameter) placed over asphalt emulsion and multilayer soil seals proved effective as barriers to a small mammal (ground squirrels) but were not of sufficient size to stop a larger animal (the prairie dog). No penetrations were made through the asphalt emulsion or the clay layer of the multilayer soil seals by either of the two mammals tested. A literature survey was prepared and published on the burrowing habits of the animals that may be found at U-tailings sites.« less
SU-E-T-457: Design and Characterization of An Economical 192Ir Hemi-Brain Small Animal Irradiator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grams, M; Wilson, Z; Sio, T
Purpose: To describe the design and dosimetric characterization of a simple and economical small animal irradiator. Methods: A high dose rate 192Ir brachytherapy source from a commercially available afterloader was used with a 1.3 centimeter thick tungsten collimator to provide sharp beam penumbra suitable for hemi-brain irradiation of mice. The unit is equipped with continuous gas anesthesia to allow robust animal immobilization. Dosimetric characterization of the device was performed with Gafchromic film. The penumbra from the small animal irradiator was compared under similar collimating conditions to the penumbra from 6 MV photons, 6 MeV electrons, and 20 MeV electrons frommore » a linear accelerator as well as 300 kVp photons from an orthovoltage unit and Monte Carlo simulated 90 MeV protons. Results: The tungsten collimator provides a sharp penumbra suitable for hemi-brain irradiation, and dose rates on the order of 200 cGy/minute were achieved. The sharpness of the penumbra attainable with this device compares favorably to those measured experimentally for 6 MV photons, and 6 and 20 MeV electron beams from a linear accelerator. Additionally, the penumbra was comparable to those measured for a 300 kVp orthovoltage beam and a Monte Carlo simulated 90 MeV proton beam. Conclusions: The small animal irradiator described here can be built for under $1,000 and used in conjunction with any commercial brachytherapy afterloader to provide a convenient and cost-effective option for small animal irradiation experiments. The unit offers high dose rate delivery and sharp penumbra, which is ideal for hemi-brain irradiation of mice. With slight modifications to the design, irradiation of sites other than the brain could be accomplished easily. Due to its simplicity and low cost, the apparatus described is an attractive alternative for small animal irradiation experiments requiring a sharp penumbra.« less
Di Ciano, Patricia; Le Foll, Bernard
2016-01-01
Gambling Disorder has serious consequences and no medications are currently approved for the treatment of this disorder. One factor that may make medication development difficult is the lack of animal models of gambling that would allow for the pre-clinical screening of efficacy. Despite this, there is evidence from clinical trials that opiate antagonists, in particular naltrexone, may be useful in treating gambling disorder. To-date, the effects of naltrexone on pre-clinical models of gambling have not been evaluated. The purpose of the present study was to evaluate the effects of naltrexone in an animal model of gambling, the rat gambling task (rGT), to determine whether this model has some predictive validity. The rGT is a model in which rats are given a choice of making either a response that produces a large reward or a small reward. The larger the reward, the greater the punishment, and thus this task requires that the animal inhibit the 'tempting' choice, as the smaller reward option produces overall the most number of rewards per session. People with gambling disorder chose the tempting option more, thus the rGT may provide a model of problem gambling. It was found that naltrexone improved performance on this task in a subset of animals that chose the 'tempting', disadvantageous choice, more at baseline. Thus, the results of this study suggest that the rGT should be further investigated as a pre-clinical model of gambling disorder and that further investigation into whether opioid antagonists are effective in treating Gambling Disorder may be warranted.
Yamamoto, Nobuyuki; Miyamoto, Koji; Katoh, Masakazu
2010-08-01
Alcohol-based hand rubs are widely used for infection control in clinical practice. However, it is known that frequent use of the alcohol-based hand rubs may cause skin irritation. To predict the skin irritation in human, animal experiments are quite useful. Especially, the Draize Test using rabbits is suitable for this purpose because their skin is highly sensitive. On the other hand, the development of alternative to animal experiments is important not only from the viewpoint of ethical aspects but also from the efficient research and development. Reconstructed human epidermis (RhE) was developed as a human skin equivalent model in vitro, and has been applied to the evaluation of skin irritation. But the RhE has not been utilized for the evaluation of alcohol-based hand rubs because of the high skin permeability and cytotoxicity of alcohols. The aim of this study was to develop a new method using the RhE in evaluation of skin irritation caused by alcohol-based hand rubs. The authors propose an experimental technique named "Skin model blowing method (SMBM)" consisting of the sequential procedure as follows; applying small amount of testing sample on RhE, blow-dry, post incubation, and cell viability measurement. According to the SMBM, the skin irritation caused by alcohol-based hand rubs could be evaluated under the similar condition of their actual use. It was found that a high correlation existed between the cell viability obtained from SMBM and the skin irritation index in rabbit which had been reported previously.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-01
... copper/brass tinklers or tube beads; 1 lot of small fragments of window glass; 1 shell bead; 1 bird bone whistle; 3 fragments of worked animal bone; 5 small pieces of wood; 5 pieces of unmodified animal bone; 1...
Towards a high sensitivity small animal PET system based on CZT detectors (Conference Presentation)
NASA Astrophysics Data System (ADS)
Abbaszadeh, Shiva; Levin, Craig
2017-03-01
Small animal positron emission tomography (PET) is a biological imaging technology that allows non-invasive interrogation of internal molecular and cellular processes and mechanisms of disease. New PET molecular probes with high specificity are under development to target, detect, visualize, and quantify subtle molecular and cellular processes associated with cancer, heart disease, and neurological disorders. However, the limited uptake of these targeted probes leads to significant reduction in signal. There is a need to advance the performance of small animal PET system technology to reach its full potential for molecular imaging. Our goal is to assemble a small animal PET system based on CZT detectors and to explore methods to enhance its photon sensitivity. In this work, we reconstruct an image from a phantom using a two-panel subsystem consisting of six CZT crystals in each panel. For image reconstruction, coincidence events with energy between 450 and 570 keV were included. We are developing an algorithm to improve sensitivity of the system by including multiple interaction events.
Effectiveness evaluation of several cattle anthelmintics via the fecal egg count reduction test.
Yazwinski, T A; Tucker, C A; Hornsby, J A; Powell, J G; Reynolds, J L; Johnson, Z B; Lindsey, W; Silver, T K
2009-07-01
Utilizing groups of cograzed, naturally infected beef-type heifers, three fecal egg count reduction tests were conducted in the later months of 2007 at the University of Arkansas. Each test was 28 days in length consisting of individual animal fecal nematode egg counts and coprocultures. Both original and generic ivermectin injectable formulations were used in two of the tests at 0.2 mg/kg BW, with FECR percentages never exceeding 90% in either test. Oral fenbendazole was evaluated at 5 and 10 mg/kg BW, with FECR%'s exceeding 90% on all occasions, but with a precipitous drop when recently treated animals were treated at the lower dose. Evaluated in one test, injectable moxidectin given at 0.2 mg/kg BW resulted in egg count reductions of 96-92% (days 7 to 28). Also evaluated in one test, albendazole delivered orally at 10 mg/kg BW was 98% and 97% effective at 17 and 28 days post-treatment. For all tests, coprocultures conducted post-treatment contained only Cooperia spp. larvae (benzimidazole use), relatively unmodified percentages of Cooperia spp. and Haemonchus spp. larvae (ivermectin use), and primarily Cooperia spp. larvae with a small percentage of Haemonchus spp. larvae (moxidectin use).
McDannold, Nathan; Arvanitis, Costas D; Vykhodtseva, Natalia; Livingstone, Margaret S
2012-07-15
The blood-brain barrier (BBB) prevents entry of most drugs into the brain and is a major hurdle to the use of drugs for brain tumors and other central nervous system disorders. Work in small animals has shown that ultrasound combined with an intravenously circulating microbubble agent can temporarily permeabilize the BBB. Here, we evaluated whether this targeted drug delivery method can be applied safely, reliably, and in a controlled manner on rhesus macaques using a focused ultrasound system. We identified a clear safety window during which BBB disruption could be produced without evident tissue damage, and the acoustic pressure amplitude where the probability for BBB disruption was 50% and was found to be half of the value that would produce tissue damage. Acoustic emission measurements seem promising for predicting BBB disruption and damage. In addition, we conducted repeated BBB disruption to central visual field targets over several weeks in animals trained to conduct complex visual acuity tasks. All animals recovered from each session without behavioral deficits, visual deficits, or loss in visual acuity. Together, our findings show that BBB disruption can be reliably and repeatedly produced without evident histologic or functional damage in a clinically relevant animal model using a clinical device. These results therefore support clinical testing of this noninvasive-targeted drug delivery method.
Nappier, Michael T; Corrigan, Virginia K; Bartl-Wilson, Lara E; Freeman, Mark; Werre, Stephen; Tempel, Eric
2017-01-01
The number of companion animal wellness visits in private practice has been decreasing, and one important factor cited is the lack of effective communication between veterinarians and pet owners regarding the importance of preventive care. Checklists have been widely used in many fields and are especially useful in areas where a complex task must be completed with multiple small steps, or when cognitive fatigue is evident. The use of checklists in veterinary medical education has not yet been thoroughly evaluated as a potential strategy to improve communication with pet owners regarding preventive care. The authors explored whether the use of a checklist based on the American Animal Hospital Association/American Veterinary Medical Association canine and feline preventive care guidelines would benefit senior veterinary students in accomplishing more complete canine and feline wellness visits. A group of students using provided checklists was compared to a control group of students who did not use checklists on the basis of their medical record notes from the visits. The students using the checklists were routinely more complete in several areas of a wellness visit vs. those who did not use the checklists. However, neither group of students routinely discussed follow-up care recommendations such as frequency or timing of follow-up visits. The study authors recommend considering checklist use for teaching and implementing wellness in companion animal primary care veterinary clinical teaching settings.
Preclinical evaluation of hydrogel sealed fluropassivated indigenous vascular prosthesis.
Unnikrishnan, Madathipat; Umashankar, P R; Viswanathan, Sidharth; Savlania, Ajay; Joseph, Roy; Muraleedharan, C V; Agrawal, Vivek; Shenoy, Sachin J; Krishnan, Lissy K; Mohanan, P V; Sabareeswaran, A
2017-11-01
Polyethylene terephthalate (PET) graft, designed and developed at our institute for vascular reconstruction, is porous to promote optimal incorporation and neointima formation, requiring pre-clotting or biomodification by sealing the pores before implantation. The objective of this study was to characterize, test and perform preclinical evaluation of hydrogel (alginate dialdehyde cross-linked gelatin) sealed fluoropassivated PET vascular prosthesis in pig model, so as to avoid pre-clotting, for its safety and efficacy before employing the indigenous and less expensive graft for clinical use. Hydrogel sealed, fluoropassivated PET vascular prosthesis were tested for haemocompatibility and toxicity followed by small animal toxicology tests and in vivo experiments in pigs receiving implantation at thoracic aorta. All 33 animals received test as well as control grafts with a plan for phased explantation at 2, 12 and 26 weeks. All animals underwent completion angiogram at the end of procedure as well as before graft explantation. Haemocompatibility tests for haemolysis and toxicity tests showed no adverse events in tested mice and rabbits. Completion angiogram showed intact anastamosis and patent graft in each animal in post-operative period and at explantation. Gross and histopathological examination showed well-encapsulated grafts, clean glistening neointima and no evidence of thrombus in both test and control grafts. Hydrogel sealed, fluoropassivated PET vascular prosthesis was found non-toxic, haemocompatible and remained patent in in vivo studies at planned intervals.
Preclinical evaluation of hydrogel sealed fluropassivated indigenous vascular prosthesis
Unnikrishnan, Madathipat; Umashankar, P.R.; Viswanathan, Sidharth; Savlania, Ajay; Joseph, Roy; Muraleedharan, C.V.; Agrawal, Vivek; Shenoy, Sachin J.; Krishnan, Lissy K.; Mohanan, P.V.; Sabareeswaran, A.
2017-01-01
Background & objectives: Polyethylene terephthalate (PET) graft, designed and developed at our institute for vascular reconstruction, is porous to promote optimal incorporation and neointima formation, requiring pre-clotting or biomodification by sealing the pores before implantation. The objective of this study was to characterize, test and perform preclinical evaluation of hydrogel (alginate dialdehyde cross-linked gelatin) sealed fluoropassivated PET vascular prosthesis in pig model, so as to avoid pre-clotting, for its safety and efficacy before employing the indigenous and less expensive graft for clinical use. Methods: Hydrogel sealed, fluoropassivated PET vascular prosthesis were tested for haemocompatibility and toxicity followed by small animal toxicology tests and in vivo experiments in pigs receiving implantation at thoracic aorta. All 33 animals received test as well as control grafts with a plan for phased explantation at 2, 12 and 26 weeks. All animals underwent completion angiogram at the end of procedure as well as before graft explantation. Results: Haemocompatibility tests for haemolysis and toxicity tests showed no adverse events in tested mice and rabbits. Completion angiogram showed intact anastamosis and patent graft in each animal in post-operative period and at explantation. Gross and histopathological examination showed well-encapsulated grafts, clean glistening neointima and no evidence of thrombus in both test and control grafts. Interpretation & conclusions: Hydrogel sealed, fluoropassivated PET vascular prosthesis was found non-toxic, haemocompatible and remained patent in in vivo studies at planned intervals. PMID:29512608
Ramírez-Iglesias, J R; Eleizalde, M C; Reyna-Bello, A; Mendoza, M
2017-06-01
In South America Trypanosoma evansi has been determined by molecular methods in cattle from Bolivia, Brazil, Colombia and Peru, reason for which the presence of this parasite is not excluded in Venezuelan livestock. Therefore, the aim of this study was to perform parasitological and molecular diagnosis of cattle trypanosomosis in small livestock units from two regions in this country. The parasitological diagnosis was carried out by MHCT and the molecular by PCR using genus-specific ITS1 primers that differentiate T. vivax and T. evansi infections. 47 cattle were evaluated in the "Laguneta de la Montaña" sector, Miranda State, where 3 animals were diagnosed as positive (6.4 %) by MHCT and 14 (30 %) by PCR as Trypanosoma spp., out of which 9 animals resulted positive for T. vivax , 3 for T. evansi and 2 with double infections. Whilst in the "San Casimiro" sector, State of Aragua, out of the 38 cattle evaluated 7 animals were diagnosed as positive (18.4 %) by MHCT and 19 (50 %) by PCR, determining only the presence of T. evansi in this locality. The molecular diagnosis by PCR using ITS1 primers allowed T. evansi detection in cattle field populations, which suggests the possible role of these animals as reservoirs in the epidemiology of the disease caused by T. evansi in Venezuela.
Inner ear test battery in guinea pig models - a review.
Young, Yi-Ho
2018-06-01
This study reviewed the development of the inner ear test battery comprising auditory brainstem response (ABR), and caloric, ocular vestibular-evoked myogenic potential (oVEMP), and cervical vestibular-evoked myogenic potential (cVEMP) tests in guinea pig models at our laboratory over the last 20 years. Detailed description of the methodology for testing the small animals is also included. Inner ear disorders, i.e. ototoxicity, noise exposure, or perilymph fistula were established in guinea pig models first. One to four weeks after operation, each animal underwent ABR, oVEMP, cVEMP, and caloric tests. Then, animals were sacrificed for morphological study in the temporal bones. Inner ear endorgans can be comprehensively evaluated in guinea pig models via an inner ear test battery, which provides thorough information on the cochlea, saccule, utricle, and semicircular canal function of guinea pigs. Coupled with morphological study in the temporal bones of the animals may help elucidate the mechanism of inner ear disorders in humans. The inner ear test battery in guinea pig models may encourage young researchers to perform basic study in animals and stimulate the progress of experimental otology which is in evolution.
Animal experimental studies using small intestine endoscope
Liu, Jin-Hua; Liu, Dan-Yang; Wang, Li; Han, Li-Ping; Qi, Zhe-Yu; Ren, Hai-Jun; Feng, Yan; Luan, Feng-Ming; Mi, Liang-Tian; Shan, Shu-Mei
2017-01-01
AIM To assess the feasibility and safety of a novel enteroscope, negative-pressure suction endoscope in examining the small intestine of a porcine model. METHODS In vitro experiments in small intestinal loops from 20 pigs and in vivo experiments in 20 living pigs were conducted. RESULTS In in vitro experiments, a negative pressure of > 0.06 MPa was necessary for optimal visualization of the intestine, and this pressure did not cause gross or histological damage to the mucosa. For satisfactory examination of the small intestine in vivo, higher negative pressure (> 1.00 MPa) was required. Despite this higher pressure, the small intestine did not show any gross or microscopic damage in the suctioned areas. The average time of examination in the living animals was 60 ± 7.67 min. The animals did not experience any apparent ill effects from the procedure. CONCLUSION Small intestine endoscope was safely performed within a reasonable time period and enabled complete visualization of the intestine in most cases. PMID:28611521
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larsson, Daniel H.; Lundstroem, Ulf; Burvall, Anna
Purpose: Small-animal studies require images with high spatial resolution and high contrast due to the small scale of the structures. X-ray imaging systems for small animals are often limited by the microfocus source. Here, the authors investigate the applicability of liquid-metal-jet x-ray sources for such high-resolution small-animal imaging, both in tomography based on absorption and in soft-tissue tumor imaging based on in-line phase contrast. Methods: The experimental arrangement consists of a liquid-metal-jet x-ray source, the small-animal object on a rotating stage, and an imaging detector. The source-to-object and object-to-detector distances are adjusted for the preferred contrast mechanism. Two different liquid-metal-jetmore » sources are used, one circulating a Ga/In/Sn alloy and the other an In/Ga alloy for higher penetration through thick tissue. Both sources are operated at 40-50 W electron-beam power with {approx}7 {mu}m x-ray spots, providing high spatial resolution in absorption imaging and high spatial coherence for the phase-contrast imaging. Results: High-resolution absorption imaging is demonstrated on mice with CT, showing 50 {mu}m bone details in the reconstructed slices. High-resolution phase-contrast soft-tissue imaging shows clear demarcation of mm-sized tumors at much lower dose than is required in absorption. Conclusions: This is the first application of liquid-metal-jet x-ray sources for whole-body small-animal x-ray imaging. In absorption, the method allows high-resolution tomographic skeletal imaging with potential for significantly shorter exposure times due to the power scalability of liquid-metal-jet sources. In phase contrast, the authors use a simple in-line arrangement to show distinct tumor demarcation of few-mm-sized tumors. This is, to their knowledge, the first small-animal tumor visualization with a laboratory phase-contrast system.« less
Ingham, S C; Hu, Y; Ané, C
2011-08-01
The objective of this study was to evaluate possible claims by advocates of small-scale dairy farming that milk from smaller Wisconsin farms is of higher quality than milk from larger Wisconsin farms. Reported bulk tank standard plate count (SPC) and somatic cell count (SCC) test results for Wisconsin dairy farms were obtained for February to December, 2008. Farms were sorted into 3 size categories using available size-tracking criteria: small (≤118 cows; 12,866 farms), large (119-713 cattle; 1,565 farms), and confined animal feeding operations (≥714 cattle; 160 farms). Group means were calculated (group=farm size category) for the farms' minimum, median, mean, 90th percentile, and maximum SPC and SCC. Statistical analysis showed that group means for median, mean, 90th percentile, and maximum SPC and SCC were almost always significantly higher for the small farm category than for the large farm and confined animal feeding operations farm categories. With SPC and SCC as quality criteria and the 3 farm size categories of ≤118, 119 to 713, and ≥714 cattle, the claim of Wisconsin smaller farms producing higher quality milk than Wisconsin larger farms cannot be supported. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Estimating Animal Abundance in Ground Beef Batches Assayed with Molecular Markers
Hu, Xin-Sheng; Simila, Janika; Platz, Sindey Schueler; Moore, Stephen S.; Plastow, Graham; Meghen, Ciaran N.
2012-01-01
Estimating animal abundance in industrial scale batches of ground meat is important for mapping meat products through the manufacturing process and for effectively tracing the finished product during a food safety recall. The processing of ground beef involves a potentially large number of animals from diverse sources in a single product batch, which produces a high heterogeneity in capture probability. In order to estimate animal abundance through DNA profiling of ground beef constituents, two parameter-based statistical models were developed for incidence data. Simulations were applied to evaluate the maximum likelihood estimate (MLE) of a joint likelihood function from multiple surveys, showing superiority in the presence of high capture heterogeneity with small sample sizes, or comparable estimation in the presence of low capture heterogeneity with a large sample size when compared to other existing models. Our model employs the full information on the pattern of the capture-recapture frequencies from multiple samples. We applied the proposed models to estimate animal abundance in six manufacturing beef batches, genotyped using 30 single nucleotide polymorphism (SNP) markers, from a large scale beef grinding facility. Results show that between 411∼1367 animals were present in six manufacturing beef batches. These estimates are informative as a reference for improving recall processes and tracing finished meat products back to source. PMID:22479559
Management of refractory epilepsy.
Muñana, Karen R
2013-05-01
The term refractory epilepsy is utilized in veterinary medicine to describe a condition in which an animal with epilepsy fails to attain satisfactory seizure control or suffers intolerable side effects despite appropriate therapy with conventional antiepileptic drugs. Refractory epilepsy is an important problem in small animal practice as it occurs in approximately one-third of dogs with epilepsy. Consequently, there is much interest in identifying ways to more effectively treat this population of animals. More than a dozen new antiepileptic drugs have been approved for humans over the last 2 decades, and several of these drugs, including gabapentin, zonisamide, levetiracetam, and pregabalin, have been evaluated for the treatment of refractory seizures in veterinary patients. Nonmedical methods to treat poorly controlled epilepsy are also being explored. The 2 alternative forms of therapy that have shown the most promise in humans with epilepsy are electrical stimulation of the brain and dietary modification, both of which have also been evaluated in dogs. This overview summarizes the available data on pharmacologic as well as nonmedical treatment options for dogs and cats with refractory epilepsy. Although many forms of therapy are currently being utilized in clinical practice, our knowledge of the safety and efficacy of these treatments is limited. Additional randomized controlled trials are needed to better evaluate these novel therapies for refractory epilepsy in dogs and cats. © 2013 Elsevier Inc. All rights reserved.
An evaluation of the accuracy and performance of lightweight GPS collars in a suburban environment.
Adams, Amy L; Dickinson, Katharine J M; Robertson, Bruce C; van Heezik, Yolanda
2013-01-01
The recent development of lightweight GPS collars has enabled medium-to-small sized animals to be tracked via GPS telemetry. Evaluation of the performance and accuracy of GPS collars is largely confined to devices designed for large animals for deployment in natural environments. This study aimed to assess the performance of lightweight GPS collars within a suburban environment, which may be different from natural environments in a way that is relevant to satellite signal acquisition. We assessed the effects of vegetation complexity, sky availability (percentage of clear sky not obstructed by natural or artificial features of the environment), proximity to buildings, and satellite geometry on fix success rate (FSR) and location error (LE) for lightweight GPS collars within a suburban environment. Sky availability had the largest affect on FSR, while LE was influenced by sky availability, vegetation complexity, and HDOP (Horizontal Dilution of Precision). Despite the complexity and modified nature of suburban areas, values for FSR (mean= 90.6%) and LE (mean = 30.1 m) obtained within the suburban environment are comparable to those from previous evaluations of GPS collars designed for larger animals and within less built-up environments. Due to fine-scale patchiness of habitat within urban environments, it is recommended that resource selection methods that are not reliant on buffer sizes be utilised for selection studies.
A Selective Critique of Animal Experiments in Human-Orientated Biological Research.
ERIC Educational Resources Information Center
Webb, G. P.
1990-01-01
The advantages and justifications for using small animals in human-oriented research are reviewed. Some of the pitfalls of extrapolating animal-derived data to humans are discussed. Several specific problems with animal experimentation are highlighted. (CW)
Schmidt, Ulrike; Keck, Martin E; Buell, Dominik R
2015-06-01
In the last couple of years, non-coding (nc) RNAs like micro-RNAs (miRNAs), small interference RNAs (siRNAs) and long ncRNAs (lncRNAs) have emerged as promising candidates for biomarkers and drug-targets in a variety of psychiatric disorders. In contrast to reports on ncRNAs in affective disorders, schizophrenia and anxiety disorders, manuscripts on ncRNAs in posttraumatic stress disorder (PTSD) and associated animal models are scarce. Aiming to stimulate ncRNA research in PTSD and to identify the hitherto most promising ncRNA candidates and associated pathways for psychotrauma research, we conducted the first review on ncRNAs in PTSD. We aimed to identify studies reporting on the expression, function and regulation of ncRNAs in PTSD patients and in animals exhibiting a PTSD-like syndrome. Following the PRISMA guidelines for systematic reviews, we systematically screened the PubMed database for clinical and animal studies on ncRNAs in PTSD, animal models for PTSD and animal models employing a classical fear conditioning paradigm. Using 112 different combinations of search terms, we retrieved 523 articles of which we finally included and evaluated three clinical and 12 animal studies. In addition, using the web-based tool DIANA miRPath v2.0, we searched for molecular pathways shared by the predicted targets of the here-evaluated miRNA candidates. Our findings suggest that mir-132, which has been found to be regulated in three of the here included studies, as well as miRNAs with an already established role in Alzheimer's disease (AD) seem to be particularly promising candidates for future miRNA studies in PTSD. These results are limited by the low number of human trials and by the heterogeneity of included animal studies. Copyright © 2015 Elsevier Ltd. All rights reserved.
Ten-year oral toxicity study with Norlestrin in rhesus monkeys.
Fitzgerald, J; de la Iglesia, F; Goldenthal, E I
1982-12-01
The long term effects of the oral contraceptive, Norlestrin, were evaluated in sexually mature female rhesus (Macaca mulatta) monkeys over a 10 year period. Norlestrin, a combination of norethindrone acetate and ethinylestradiol (50:1) was given orally on a continuous cyclic regimen of 21 d of dosing followed by 7 d without treatment. Groups of 16 monkeys each received the drug at dose levels of 0.05, 0.51, and 2.55 mg/kg representing multiples of 1, 10, and 50 times the human dose, respectively. A comparable group of 16 animals remained untreated and served as controls. Selected clinical and laboratory parameters were monitored throughout the study and all animals were necropsied and evaluated for gross and histopathologic changes. All dose levels were well tolerated and survival was not affected. There were no consistent treatment-related alterations in coagulation or other clinical laboratory parameters. Ophthalmologically, macular pigmentary anomalies were observed in all groups. Treatment-associated pathologic findings, representing exaggerated pharmacological responses with superimposed senile changes, including ovarian and uterine atrophy and dilatation of acini and ducts in the mammary gland. Periodic vaginal cytologic examination and mammary gland palpation did not demonstrate drug related changes. A small number of neoplasms was seen in all groups and a granulosa cell carcinoma of the ovary occurred in a control animal. The benign tumors consisted of three cutaneous papillomas: one in a low dose and one in a high dose animal, a uterine leiomyoma in one high dose animal, and a pancreatic duct adenoma in one low dose animal. The results of this study indicate that Norlestrin had no significant toxic manifestations or tumorigenic potential when administered on a cyclic regimen to female rhesus monkeys at levels up to 50 times the human dose for ten yr.
Martinez, Marie-José; Durand, Benoit; Calavas, Didier; Ducrot, Christian
2010-06-01
Demonstrating disease freedom is becoming important in different fields including animal disease control. Most methods consider sampling only from a homogeneous population in which each animal has the same probability of becoming infected. In this paper, we propose a new methodology to calculate the probability of detecting the disease if it is present in a heterogeneous population of small size with potentially different risk groups, differences in risk being defined using relative risks. To calculate this probability, for each possible arrangement of the infected animals in the different groups, the probability that all the animals tested are test-negative given this arrangement is multiplied by the probability that this arrangement occurs. The probability formula is developed using the assumption of a perfect test and hypergeometric sampling for finite small size populations. The methodology is applied to scrapie, a disease affecting small ruminants and characterized in sheep by a strong genetic susceptibility defining different risk groups. It illustrates that the genotypes of the tested animals influence heavily the confidence level of detecting scrapie. The results present the statistical power for substantiating disease freedom in a small heterogeneous population as a function of the design prevalence, the structure of the sample tested, the structure of the herd and the associated relative risks. (c) 2010 Elsevier B.V. All rights reserved.
Luethy, D; Stefanovski, D; Salber, R; Sweeney, R W
2017-11-01
Calculation of desired whole blood transfusion volume relies on an estimate of an animal's circulating blood volume, generally accepted to be 0.08 L/kg or 8% of the animal's body weight in kilograms. To use packed cell volume before and after whole blood transfusion to evaluate the accuracy of a commonly used equation to predict packed cell volume after transfusion in small ruminants and South American camelids; to determine the nature and frequency of adverse transfusion reactions in small ruminants and camelids after whole blood transfusion. Fifty-eight small ruminants and 22 alpacas that received whole blood transfusions for anemia. Retrospective case series; medical record review for small ruminants and camelids that received whole blood transfusions during hospitalization. Mean volume of distribution of blood as a fraction of body weight in sheep (0.075 L/kg, 7.5% BW) and goats (0.076 L/kg, 7.6% BW) differed significantly (P < 0.01) from alpacas (0.103 L/kg, 10.3% BW). Mild transfusion reactions were noted in 16% of transfusions. The generally accepted value of 8% for circulating blood volume (volume of distribution of blood) is adequate for calculation of transfusion volumes; however, use of the species-specific circulating blood volume can improve calculation of transfusion volume to predict and achieve desired packed cell volume. The incidence of transfusion reactions in small ruminants and camelids is low. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.
An inexpensive and portable microvolumeter for rapid evaluation of biological samples.
Douglass, John K; Wcislo, William T
2010-08-01
We describe an improved microvolumeter (MVM) for rapidly measuring volumes of small biological samples, including live zooplankton, embryos, and small animals and organs. Portability and low cost make this instrument suitable for widespread use, including at remote field sites. Beginning with Archimedes' principle, which states that immersing an arbitrarily shaped sample in a fluid-filled container displaces an equivalent volume, we identified procedures that maximize measurement accuracy and repeatability across a broad range of absolute volumes. Crucial steps include matching the overall configuration to the size of the sample, using reflected light to monitor fluid levels precisely, and accounting for evaporation during measurements. The resulting precision is at least 100 times higher than in previous displacement-based methods. Volumes are obtained much faster than by traditional histological or confocal methods and without shrinkage artifacts due to fixation or dehydration. Calibrations using volume standards confirmed accurate measurements of volumes as small as 0.06 microL. We validated the feasibility of evaluating soft-tissue samples by comparing volumes of freshly dissected ant brains measured with the MVM and by confocal reconstruction.
Using the NEMA NU 4 PET image quality phantom in multipinhole small-animal SPECT.
Harteveld, Anita A; Meeuwis, Antoi P W; Disselhorst, Jonathan A; Slump, Cornelis H; Oyen, Wim J G; Boerman, Otto C; Visser, Eric P
2011-10-01
Several commercial small-animal SPECT scanners using multipinhole collimation are presently available. However, generally accepted standards to characterize the performance of these scanners do not exist. Whereas for small-animal PET, the National Electrical Manufacturers Association (NEMA) NU 4 standards have been defined in 2008, such standards are still lacking for small-animal SPECT. In this study, the image quality parameters associated with the NEMA NU 4 image quality phantom were determined for a small-animal multipinhole SPECT scanner. Multiple whole-body scans of the NEMA NU 4 image quality phantom of 1-h duration were performed in a U-SPECT-II scanner using (99m)Tc with activities ranging between 8.4 and 78.2 MBq. The collimator contained 75 pinholes of 1.0-mm diameter and had a bore diameter of 98 mm. Image quality parameters were determined as a function of average phantom activity, number of iterations, postreconstruction spatial filter, and scatter correction. In addition, a mouse was injected with (99m)Tc-hydroxymethylene diphosphonate and was euthanized 6.5 h after injection. Multiple whole-body scans of this mouse of 1-h duration were acquired for activities ranging between 3.29 and 52.7 MBq. An increase in the number of iterations was accompanied by an increase in the recovery coefficients for the small rods (RC(rod)), an increase in the noise in the uniform phantom region, and a decrease in spillover ratios for the cold-air- and water-filled scatter compartments (SOR(air) and SOR(wat)). Application of spatial filtering reduced image noise but lowered RC(rod). Filtering did not influence SOR(air) and SOR(wat). Scatter correction reduced SOR(air) and SOR(wat). The effect of total phantom activity was primarily seen in a reduction of image noise with increasing activity. RC(rod), SOR(air), and SOR(wat) were more or less constant as a function of phantom activity. The relation between acquisition and reconstruction settings and image quality was confirmed in the (99m)Tc-hydroxymethylene diphosphonate mouse scans. Although developed for small-animal PET, the NEMA NU 4 image quality phantom was found to be useful for small-animal SPECT as well, allowing for objective determination of image quality parameters and showing the trade-offs between several of these parameters on variation of acquisition and reconstruction settings.
Preclinical Evaluation of RYM1, a Matrix Metalloproteinase-Targeted Tracer for Imaging Aneurysm.
Toczek, Jakub; Ye, Yunpeng; Gona, Kiran; Kim, Hye-Yeong; Han, Jinah; Razavian, Mahmoud; Golestani, Reza; Zhang, Jiasheng; Wu, Terence L; Jung, Jae-Joon; Sadeghi, Mehran M
2017-08-01
Matrix metalloproteinases (MMPs) play a key role in abdominal aortic aneurysm (AAA) development. Accordingly, MMP-targeted imaging provides important information regarding vessel wall biology in the course of aneurysm development. Given the small size of the vessel wall and its proximity with blood, molecular imaging of aneurysm optimally requires highly sensitive tracers with rapid blood clearance. To this end, we developed a novel hydrosoluble zwitterionic MMP inhibitor, RYM, on the basis of which a pan-MMP tracer, RYM1, was designed. Here, we describe the development and preclinical evaluation of RYM1 in comparison with RP805, a commonly used pan-MMP tracer in murine models of aneurysm. Methods: The macrocyclic hydroxamate-based pan-MMP inhibitor coupled with 6-hydrazinonicotinamide, RYM1, was synthesized and labeled with 99m Tc. Radiochemical stability of 99m Tc-RYM1 was evaluated by radio-high-performance liquid chromatography analysis. Tracer blood kinetics and biodistribution were compared with 99m Tc-RP805 in C57BL/6J mice ( n = 10). 99m Tc-RYM1 binding to aneurysm and specificity were evaluated by quantitative autoradiography in apolipoprotein E-deficient (apoE -/- ) mice with CaCl 2 -induced carotid aneurysm ( n = 11). Angiotensin II-infused apoE -/- ( n = 16) mice were used for small-animal SPECT/CT imaging. Aortic tissue MMP activity and macrophage marker CD68 expression were assessed by zymography and reverse-transcription polymerase chain reaction. Results: RYM1 showed nanomolar range inhibition constants for several MMPs. 99m Tc-RYM1 was radiochemically stable in mouse blood for 5 h and demonstrated rapid renal clearance and lower blood levels in vivo compared with 99m Tc-RP805. 99m Tc-RYM1 binding to aneurysm and its specificity were shown by autoradiography in carotid aneurysm. Angiotensin II infusion in apoE -/- mice for 4 wk resulted in AAA formation in 36% (4/11) of surviving animals. In vivo 99m Tc-RYM1 small-animal SPECT/CT images showed higher uptake of the tracer in AAA than nondilated aortae. Finally, aortic uptake of 99m Tc-RYM1 in vivo correlated with aortic MMP activity and CD68 expression. Conclusion: The newly developed pan-MMP inhibitor-based tracer 99m Tc-RYM1 displays favorable pharmacokinetics for early vascular imaging and enables specific detection of inflammation and MMP activity in aneurysm. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
Dissemination of parasites by animal movements in small ruminant farms.
Vasileiou, N G C; Fthenakis, G C; Papadopoulos, E
2015-09-30
The present paper discusses the spread of parasites by animal movements in small ruminant farms; it focuses in dissemination of parasitic forms that would lead to subsequent infection of sheep or goats. Systems of small ruminant production involve a component of animal movement (e.g., grazing) as part of routine husbandry, which favors spread of parasitic forms; that refers mainly to parasites of the digestive system (nematodes, trematodes, cestodes, protozoa), as well as helminthes of the respiratory system, although dissemination of the various parasitic forms in the environment would not always result to subsequent infection; external parasites may also be disseminated during movements, e.g., to inhabit wooden poles used in fencing. New livestock into a farm constitutes a biosecurity hazard and the most common means to introducing new parasitic pathogens into a farm; in contemporary small ruminant health management, this contributes in dissemination of anthelmintic resistant parasitic strains; other parasitic disease agents (e.g., mange mites, ticks) may also be spread into a farm that way. Often, especially in small scale farming, visits of rams or bucks take place from one farm to another during the mating season; in such cases, ectoparasites (e.g., mange mites) can be disseminated through direct contact of animals, as well other pathogens (e.g., Toxoplasma gondii, Neospora caninum) via the semen. During transportation of sheep/goats, parasitic forms can also spread, as well as during movement of sheep or goats to slaughterhouses, in which case dogs present in these places would contribute to their dissemination. Spread of life forms of various parasites can also occur from animal species present in the environment of sheep or goats; these include animals present within a farm, stray dogs roaming around a farm (e.g., for spread of Multiceps multiceps, Echinococcus granulosus, Taenia hydatigena, N. caninum), cats commanding the environment of a farm (e.g., for spread of T. gondii), cats or rats responsible for dissemination of fleas, which may also be spread by humans as well, and, finally, wildlife animals. Finally, life forms of parasites of small ruminants may be also spread indirectly, by material associated with sheep or goats (e.g., materials of humans visiting farms, animal feeds) that had been contaminated by faecal material of animals. Copyright © 2015 Elsevier B.V. All rights reserved.
Experience with a small animal hyperthermia ultrasound system (SAHUS): report on 83 tumours
NASA Astrophysics Data System (ADS)
Novák, P.; Moros, E. G.; Parry, J. J.; Rogers, B. E.; Myerson, R. J.; Zeug, A.; Locke, J. E.; Rossin, R.; Straube, W. L.; Singh, A. K.
2005-11-01
An external local ultrasound (US) system was developed to induce controlled hyperthermia of subcutaneously implanted tumours in small animals (e.g., mice and rats). It was designed to be compatible with a small animal positron emission tomography scanner (microPET) to facilitate studies of hyperthermia-induced tumour re-oxygenation using a PET radiopharmaceutical, but it is applicable for any small animal study requiring controlled heating. The system consists of an acrylic applicator bed with up to four independent 5 MHz planar disc US transducers of 1 cm in diameter, a four-channel radiofrequency (RF) generator, a multiple thermocouple thermometry unit, and a personal computer with custom monitoring and controlling software. Although the system presented here was developed to target tumours of up to 1 cm in diameter, the applicator design allows for different piezoelectric transducers to be exchanged and operated within the 3.5-6.5 MHz band to target different tumour sizes. Temperature feedback control software was developed on the basis of a proportional-integral-derivative (PID) approach when the measured temperatures were within a selectable temperature band about the target temperature. Outside this band, an on/off control action was applied. Perfused tissue-mimicking phantom experiments were performed to determine optimum controller gain constants, which were later employed successfully in animal experiments. The performance of the SAHUS (small animal hyperthermia ultrasound system) was tested using several tumour types grown in thighs of female nude (nu/nu) mice. To date, the system has successfully treated 83 tumours to target temperatures in the range of 41-43 °C for periods of 65 min on average.
Factors associated with the career path choices of veterinarians in western Canada
Jelinski, Murray D.; Campbell, John R.; Naylor, Jonathan M.; Lawson, Karen L.; Derkzen, Dena
2009-01-01
This second of 2 articles, relating to the veterinary profession in western Canada, explores the factors associated with veterinarians’ career path choices. Among other factors, companion animal (small animal and equine) (CA) practitioners were less likely to have been raised in, or near to, a small center (≤ 10 000), were more concerned with their workload (hours of work and number of nights on-call), and preferred to work in progressive practices. Food animal (FA) practitioners were more likely to be male, have been raised in a small center, have been raised in the Province of Saskatchewan, and to have self-assessed themselves as having an above average knowledge of agriculture at the time they applied for admission to veterinary college. Mixed animal (MA) practitioners had more factors in common with FA than with CA practitioners. Three main factors were associated with leaving mixed or food animal practice: hours of work and too many nights on-call, the level of remuneration, and lack of support and mentorship. PMID:19721783
2017-10-01
at the site of the VML. Prior small and large animal studies in our laboratory have demonstrated that minced muscle autograft (MMA), by virtue of...minced and placed intramuscularly at the site of the VML. Prior small and large animal studies in our laboratory have demonstrated that minced muscle...significant delay in the project initiation. First, a large animal study at the ISR indicated some concerns with the extra cellular matrix allograft that
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bookman, M.A.; Bast, R.C. Jr.
Small volume residual peritoneal disease in patients undergoing therapy for ovarian carcinoma remains an attractive, but elusive, target for immunobiological therapy. Hypothetical advantages and disadvantages of regional peritoneal therapy are being better defined through increased clinical experience and more sophisticated animal models. Developments in cytokine biology, adoptive cellular therapy, monoclonal antibody conjugation, and molecular biology continue to provide an exciting, and nearly overwhelming, array of reagents for clinical evaluation. Ongoing and anticipated investigational trials should provide intriguing data in years to follow.198 references.
Jahanmir, Said; Hunsberger, Andrew Z; Heshmat, Hooshang; Tomaszewski, Michael J; Walton, James F; Weiss, William J; Lukic, Branka; Pae, William E; Zapanta, Conrad M; Khalapyan, Tigran Z
2008-05-01
The MiTiHeart (MiTiHeart Corporation, Gaithersburg, MD, USA) left ventricular assist device (LVAD), a third-generation blood pump, is being developed for destination therapy for adult heart failure patients of small to medium frame that are not being served by present pulsatile devices. The pump design is based on a novel, patented, hybrid passive/active magnetic bearing system with backup hydrodynamic thrust bearing and exhibits low power loss, low vibration, and low hemolysis. Performance of the titanium alloy prototype was evaluated in a series of in vitro tests with blood analogue to map out the performance envelop of the pump. The LVAD prototype was implanted in a calf animal model, and the in vivo pump performance was evaluated. The animal's native heart imparted a strong pulsatility to the flow rate. These tests confirmed the efficacy of the MiTiHeart LVAD design and confirmed that the pulsatility does not adversely affect the pump performance.
Connolly, S M; Cromie, A R; Berry, D P
2016-05-01
The increased demand for animal-derived protein and energy for human consumption will have to be achieved through a combination of improved animal genetic merit and better management strategies. The objective of the present study was to quantify whether differences in genetic merit among animals materialised into phenotypic differences in commercial herds. Carcass phenotypes on 156 864 animals from 7301 finishing herds were used, which included carcass weight (kg), carcass conformation score (scale 1 to 15), carcass fat score (scale 1 to 15) at slaughter as well as carcass price. The price per kilogram and the total carcass value that the producer received for the animal at slaughter was also used. A terminal index, calculated in the national genetic evaluations, was obtained for each animal. The index was based on pedigree index for calving performance, feed intake and carcass traits from the national genetic evaluations. Animals were categorised into four terminal index groups on the basis of genetic merit estimates that were derived before the expression of the phenotypic information by the validation animals. The association between terminal index and phenotypic performance at slaughter was undertaken using mixed models; whether the association differed by gender (i.e. young bulls, steers and heifers) or by early life experiences (animals born in a dairy herd or beef herd) was also investigated. The regression coefficient of phenotypic carcass weight, carcass conformation and carcass fat on their respective estimated breeding values (EBVs) was 0.92 kg, 1.08 units and 0.79 units, respectively, which is close to the expectation of one. Relative to animals in the lowest genetic merit group, animals in the highest genetic merit group had, on average, a 38.7 kg heavier carcass, with 2.21 units greater carcass conformation, and 0.82 units less fat. The superior genetic merit animals were, on average, slaughtered 6 days younger than their inferior genetic merit contemporaries. The superior carcass characteristics of the genetically elite animals materialised in carcasses worth €187 more than those of the lowest genetic merit animals. Although the phenotypic difference in carcass traits of animals divergent in terminal index differed statistically by animal gender and early life experience, the detected interactions were generally biologically small. This study clearly indicates that selection on an appropriate terminal index will produce higher performing animals and this was consistent across all production systems investigated.
Effects of antenna length and material on output power and detection of miniature radio transmitters
Beeman, J.W.; Bower, N.; Juhnke, S.; Dingmon, L.; Van Den, Tillaart; Thomas, T.
2007-01-01
The optimal antenna of transmitters used in small aquatic animals is often a compromise between efficient radio wave propagation and effects on animal behavior. Radio transmission efficiency generally increases with diameter and length of the conductor, but increased antenna length or weight can adversely affect animal behavior. We evaluated the effects of changing antenna length and material on the subsequent tag output power, reception, and detection of tagged fish. In a laboratory, we compared the relative signal strengths in water of 150 MHz transmitters over a range of antenna lengths (from 6 to 30 cm) and materials (one weighing about half of the other). The peak relative signal strengths were at 20 and 22 cm, which are approximately one wavelength underwater at the test frequency. The peak relative signal strengths at these lengths were approximately 50% greater than those of 30 cm antennas, a length commonly used in fisheries research. Few significant differences were present in distances for the operator to hear or the telemetry receiver to decode transmitters from a boat-mounted receiving system based on antenna length, but the percent of tagged fish detected passing a hydroelectric dam fitted with an array of receiving systems was significantly greater at the antenna length with peak output power in laboratory tests. This study indicates careful choice of antenna length and material of small transmitters can be used to reduce weight and possible antenna effects on animal behavior, to maximize tag output power and detection, or to balance these factors based on the needs of the application. ?? 2007 Springer Science+Business Media B.V.
Pestka, James J.
2013-01-01
Although the acute toxic effects of trichothecene mycotoxin deoxynivalenol (DON or vomitoxin), a known cause of human food poisoning, have been well characterized in several animal species, much less is known about closely related 8-ketotrichothecenes that similarly occur in cereal grains colonized by toxigenic fusaria. To address this, we compared potencies of DON, 15-acetyldeoxynivalenol (15-ADON), 3-acetyldeoxynivalenol (3-ADON), fusarenon X (FX), and nivalenol (NIV) in the mink emesis model following intraperitoneal (ip) and oral administration. All five congeners dose-dependently induced emesis by both administration methods. With increasing doses, there were marked decreases in latency to emesis with corresponding increases in emesis duration and number of emetic events. The effective doses resulting in emetic events in 50% of the animals for ip exposure to DON, 15-ADON, 3-ADON, FX, and NIV were 80, 170, 180, 70, and 60 µg/kg bw, respectively, and for oral exposure, they were 30, 40, 290, 30, and 250 µg/kg bw, respectively. The emetic potency of DON determined here was comparable to that reported in analogous studies conducted in pigs and dogs, suggesting that the mink is a suitable small animal model for investigating acute trichothecene toxicity. The use of a mouse pica model, based on the consumption of kaolin, was also evaluated as a possible surrogate for studying emesis but was found unsuitable. From a public health perspective, comparative emetic potency data derived from small animal models such as the mink should be useful for establishing toxic equivalency factors for DON and other trichothecenes. PMID:22997060
A quality assurance phantom for the performance evaluation of volumetric micro-CT systems
NASA Astrophysics Data System (ADS)
Du, Louise Y.; Umoh, Joseph; Nikolov, Hristo N.; Pollmann, Steven I.; Lee, Ting-Yim; Holdsworth, David W.
2007-12-01
Small-animal imaging has recently become an area of increased interest because more human diseases can be modeled in transgenic and knockout rodents. As a result, micro-computed tomography (micro-CT) systems are becoming more common in research laboratories, due to their ability to achieve spatial resolution as high as 10 µm, giving highly detailed anatomical information. Most recently, a volumetric cone-beam micro-CT system using a flat-panel detector (eXplore Ultra, GE Healthcare, London, ON) has been developed that combines the high resolution of micro-CT and the fast scanning speed of clinical CT, so that dynamic perfusion imaging can be performed in mice and rats, providing functional physiological information in addition to anatomical information. This and other commercially available micro-CT systems all promise to deliver precise and accurate high-resolution measurements in small animals. However, no comprehensive quality assurance phantom has been developed to evaluate the performance of these micro-CT systems on a routine basis. We have designed and fabricated a single comprehensive device for the purpose of performance evaluation of micro-CT systems. This quality assurance phantom was applied to assess multiple image-quality parameters of a current flat-panel cone-beam micro-CT system accurately and quantitatively, in terms of spatial resolution, geometric accuracy, CT number accuracy, linearity, noise and image uniformity. Our investigations show that 3D images can be obtained with a limiting spatial resolution of 2.5 mm-1 and noise of ±35 HU, using an acquisition interval of 8 s at an entrance dose of 6.4 cGy.
Robotically assisted small animal MRI-guided mouse biopsy
NASA Astrophysics Data System (ADS)
Wilson, Emmanuel; Chiodo, Chris; Wong, Kenneth H.; Fricke, Stanley; Jung, Mira; Cleary, Kevin
2010-02-01
Small mammals, namely mice and rats, play an important role in biomedical research. Imaging, in conjunction with accurate therapeutic agent delivery, has tremendous value in small animal research since it enables serial, non-destructive testing of animals and facilitates the study of biomarkers of disease progression. The small size of organs in mice lends some difficulty to accurate biopsies and therapeutic agent delivery. Image guidance with the use of robotic devices should enable more accurate and repeatable targeting for biopsies and delivery of therapeutic agents, as well as the ability to acquire tissue from a pre-specified location based on image anatomy. This paper presents our work in integrating a robotic needle guide device, specialized stereotaxic mouse holder, and magnetic resonance imaging, with a long-term goal of performing accurate and repeatable targeting in anesthetized mice studies.
High-resolution short-exposure small-animal laboratory x-ray phase-contrast tomography
NASA Astrophysics Data System (ADS)
Larsson, Daniel H.; Vågberg, William; Yaroshenko, Andre; Yildirim, Ali Önder; Hertz, Hans M.
2016-12-01
X-ray computed tomography of small animals and their organs is an essential tool in basic and preclinical biomedical research. In both phase-contrast and absorption tomography high spatial resolution and short exposure times are of key importance. However, the observable spatial resolutions and achievable exposure times are presently limited by system parameters rather than more fundamental constraints like, e.g., dose. Here we demonstrate laboratory tomography with few-ten μm spatial resolution and few-minute exposure time at an acceptable dose for small-animal imaging, both with absorption contrast and phase contrast. The method relies on a magnifying imaging scheme in combination with a high-power small-spot liquid-metal-jet electron-impact source. The tomographic imaging is demonstrated on intact mouse, phantoms and excised lungs, both healthy and with pulmonary emphysema.
[New drugs for small animals in 2017].
Emmerich, Ilka Ute
2018-04-01
In 2017 the active pharmaceutical ingredient Lokivetmab (Cytopoint®), a caninized anti-canine Interleukin 31 monoclonal antibody, was released on the German market for small animals. One substance was authorized for an additional species. Sarolaner, an ectoparasiticide of the isoxazoline group, is now authorized for use in combination with Selamectin (Stronghold® Plus) additionally for cats. The testosterone derivate Nandrolone (Nandrosol®) and the combination of the benzodiazepine Zolazepam with the "dissociative anesthetic" Tiletamine (Zoletil®) were once again authorized. Furthermore, two veterinary drugs with a new combination of active ingredients, one drug with a new active ingredient and two veterinary drugs with a new pharmaceutical form have been launched on the market for small animals. Schattauer GmbH.
Cone Beam X-Ray Luminescence Tomography Imaging Based on KA-FEM Method for Small Animals.
Chen, Dongmei; Meng, Fanzhen; Zhao, Fengjun; Xu, Cao
2016-01-01
Cone beam X-ray luminescence tomography can realize fast X-ray luminescence tomography imaging with relatively low scanning time compared with narrow beam X-ray luminescence tomography. However, cone beam X-ray luminescence tomography suffers from an ill-posed reconstruction problem. First, the feasibility of experiments with different penetration and multispectra in small animal has been tested using nanophosphor material. Then, the hybrid reconstruction algorithm with KA-FEM method has been applied in cone beam X-ray luminescence tomography for small animals to overcome the ill-posed reconstruction problem, whose advantage and property have been demonstrated in fluorescence tomography imaging. The in vivo mouse experiment proved the feasibility of the proposed method.
[New drugs for small animals in 2010].
Emmerich, I U
2011-01-01
In 2010, no active pharmaceutical ingredients were released on the German market for small animals. Furthermore, no additional substances were authorized for additional species. Only one drug with an interesting new pharmaceutical form, two products with a new strength and one drug, which is interesting because of other criteria, were added to the market for small animals. In addition, nine active pharmaceutical ingredients with approval for use in human medicine, which are of potential interest for veterinary medicine, entered the market in 2010. Those are the analgesic Tapentadol, the antiallergicum Bilastine, the antiarrhythmics Dronedarone and Vernakalant, the antihaemorrhagic Eltrombopag, the bronchodilator Roflumilast, the hormone Corifollitropin alfa, the laxative Prucalopride and the cytostatic Mifamurtide.
NASA Astrophysics Data System (ADS)
Cao, Liji; Peter, Jörg
2013-06-01
The adoption of axially oriented line illumination patterns for fluorescence excitation in small animals for fluorescence surface imaging (FSI) and fluorescence optical tomography (FOT) is being investigated. A trimodal single-photon-emission-computed-tomography/computed-tomography/optical-tomography (SPECT-CT-OT) small animal imaging system is being modified for employment of point- and line-laser excitation sources. These sources can be arbitrarily positioned around the imaged object. The line source is set to illuminate the object along its entire axial direction. Comparative evaluation of point and line illumination patterns for FSI and FOT is provided involving phantom as well as mouse data. Given the trimodal setup, CT data are used to guide the optical approaches by providing boundary information. Furthermore, FOT results are also being compared to SPECT. Results show that line-laser illumination yields a larger axial field of view (FOV) in FSI mode, hence faster data acquisition, and practically acceptable FOT reconstruction throughout the whole animal. Also, superimposed SPECT and FOT data provide additional information on similarities as well as differences in the distribution and uptake of both probe types. Fused CT data enhance further the anatomical localization of the tracer distribution in vivo. The feasibility of line-laser excitation for three-dimensional fluorescence imaging and tomography is demonstrated for initiating further research, however, not with the intention to replace one by the other.
Selection methods for resistance to and tolerance of helminths in livestock
McManus, Concepta; Paim, Tiago do Prado; de Melo, Cristiano Barros; Brasil, Bruno S. A. F.; Paiva, Samuel R.
2014-01-01
Helminthiases are among the most important livestock diseases worldwide, in particular for small ruminants, which are the focus of this review. Resource Allocation Theory implies that high-productivity farm animals proportionate insufficient resources for adequate coping with stressful conditions. Significant differences between breeds and within breeds are seen, as well as genotype vs. environment interactions. With improvement of genetic host resistance to infection, transmission of infection will be impacted. On the other hand, genetic improvement of resilience can lead to a reduction in clinical signs of disease, but not necessarily reduce transmission of infection to other animals. Faecal egg count (FEC) is the main measurement used to evaluate helminthiasis load, despite the fact that the protocols and analytical methods can affect the results, and the FEC data frequently shows aggregative, negative skewed distribution, and a high coefficient of variation. Mass selection where heritability is generally medium to low generally produces slow results and low economic returns. Many studies have been published linking resistance to nematodes in livestock to Quantitative Trait Loci and most studies have concentrated on chromosomes where the major histocompatibility complex region is located. Nevertheless, these complex traits have been seen to be affected by thousands of variants that each has a small effect. More recent studies have shown that genome-wide selection strategies can be useful in selecting animals for improved production and resistance traits in this case. PMID:25350972
Paulmurugan, Ramasamy; Gambhir, Sanjiv S.
2014-01-01
Networks of protein interactions execute many different intracellular pathways. Small molecules either synthesized within the cell or obtained from the external environment mediate many of these protein-protein interactions. The study of these small molecule–mediated protein-protein interactions is important in understanding abnormal signal transduction pathways in a variety of disorders, as well as in optimizing the process of drug development and validation. In this study, we evaluated the rapamycin-mediated interaction of the human proteins FK506-binding protein (FKBP12) rapamycin-binding domain (FRB) and FKBP12 by constructing a fusion of these proteins with a split-Renilla luciferase or a split enhanced green fluorescent protein (split-EGFP) such that complementation of the reporter fragments occurs in the presence of rapamycin. Different linker peptides in the fusion protein were evaluated for the efficient maintenance of complemented reporter activity. This system was studied in both cell culture and xenografts in living animals. We found that peptide linkers with two or four EAAAR repeat showed higher protein-protein interaction–mediated signal with lower background signal compared with having no linker or linkers with amino acid sequences GGGGSGGGGS, ACGSLSCGSF, and ACGSLSCGS-FACGSLSCGSF. A 9 ± 2-fold increase in signal intensity both in cell culture and in living mice was seen compared with a system that expresses both reporter fragments and the interacting proteins separately. In this fusion system, rapamycin induced heterodimerization of the FRB and FKBP12 moieties occurred rapidly even at very lower concentrations (0.00001 nmol/L) of rapamycin. For a similar fusion system employing split-EGFP, flow cytometry analysis showed significant level of rapamycin-induced complementation. PMID:16103094
Paulmurugan, Ramasamy; Gambhir, Sanjiv S
2005-08-15
Networks of protein interactions execute many different intracellular pathways. Small molecules either synthesized within the cell or obtained from the external environment mediate many of these protein-protein interactions. The study of these small molecule-mediated protein-protein interactions is important in understanding abnormal signal transduction pathways in a variety of disorders, as well as in optimizing the process of drug development and validation. In this study, we evaluated the rapamycin-mediated interaction of the human proteins FK506-binding protein (FKBP12) rapamycin-binding domain (FRB) and FKBP12 by constructing a fusion of these proteins with a split-Renilla luciferase or a split enhanced green fluorescent protein (split-EGFP) such that complementation of the reporter fragments occurs in the presence of rapamycin. Different linker peptides in the fusion protein were evaluated for the efficient maintenance of complemented reporter activity. This system was studied in both cell culture and xenografts in living animals. We found that peptide linkers with two or four EAAAR repeat showed higher protein-protein interaction-mediated signal with lower background signal compared with having no linker or linkers with amino acid sequences GGGGSGGGGS, ACGSLSCGSF, and ACGSLSCGSFACGSLSCGSF. A 9 +/- 2-fold increase in signal intensity both in cell culture and in living mice was seen compared with a system that expresses both reporter fragments and the interacting proteins separately. In this fusion system, rapamycin induced heterodimerization of the FRB and FKBP12 moieties occurred rapidly even at very lower concentrations (0.00001 nmol/L) of rapamycin. For a similar fusion system employing split-EGFP, flow cytometry analysis showed significant level of rapamycin-induced complementation.
Coupler for surgery on small animals
NASA Technical Reports Server (NTRS)
Johnson, J. E., Jr.; Swartz, P. F.
1979-01-01
Minicoupler simplifies exchange of fluids with organs of laboratory animals enabling one person to perform surgery on experimental animals such as rats and mice. Innovation eliminates obstructing hands and instruments from areas of surgery.
NASA Astrophysics Data System (ADS)
Hu, Philip; Mingozzi, Marco; Higgins, Laura M.; Ganapathy, Vidya; Zevon, Margot; Riman, Richard E.; Roth, Charles M.; Moghe, Prabhas V.; Pierce, Mark C.
2015-03-01
We report the design, calibration, and testing of a pre-clinical small animal imaging platform for use with short-wave infrared (SWIR) emitting contrast agents. Unlike materials emitting at visible or near-infrared wavelengths, SWIR-emitting agents require detection systems with sensitivity in the 1-2 μm wavelength region, beyond the range of commercially available small animal imagers. We used a collimated 980 nm laser beam to excite rare-earth-doped NaYF4:Er,Yb nanocomposites, as an example of a SWIR emitting material under development for biomedical imaging applications. This beam was raster scanned across the animal, with fluorescence in the 1550 nm wavelength region detected by an InGaAs area camera. Background adjustment and intensity non-uniformity corrections were applied in software. The final SWIR fluorescence image was overlaid onto a standard white-light image for registration of contrast agent uptake with respect to anatomical features.
Transmission line based thermoacoustic imaging of small animals
NASA Astrophysics Data System (ADS)
Omar, Murad; Kellnberger, Stephan; Sergiadis, George; Razansky, Daniel; Ntziachristos, Vasilis
2013-06-01
We have generated high resolution images of RF-Contrast in small animals using nearfield thermoacoustic system. This enables us to see some anatomical features of a mouse such as the heart, the spine and the boundary. OCIS codes: (000.0000) General; (000.0000) General [8-pt. type. For codes, see www.opticsinfobase.org/submit/ocis.
In Vivo Small Animal Imaging using Micro-CT and Digital Subtraction Angiography
Badea, C.T.; Drangova, M.; Holdsworth, D.W.; Johnson, G.A.
2009-01-01
Small animal imaging has a critical role in phenotyping, drug discovery, and in providing a basic understanding of mechanisms of disease. Translating imaging methods from humans to small animals is not an easy task. The purpose of this work is to review in vivo X-ray based small animal imaging, with a focus on in vivo micro-computed tomography (micro-CT) and digital subtraction angiography (DSA). We present the principles, technologies, image quality parameters and types of applications. We show that both methods can be used not only to provide morphological, but also functional information, such as cardiac function estimation or perfusion. Compared to other modalities, x-ray based imaging is usually regarded as being able to provide higher throughput at lower cost and adequate resolution. The limitations are usually associated with the relatively poor contrast mechanisms and potential radiation damage due to ionizing radiation, although the use of contrast agents and careful design of studies can address these limitations. We hope that the information will effectively address how x-ray based imaging can be exploited for successful in vivo preclinical imaging. PMID:18758005
Chan, Ho Sze; Konijnenberg, Mark W; de Blois, Erik; Koelewijn, Stuart; Baum, Richard P; Morgenstern, Alfred; Bruchertseifer, Frank; Breeman, Wouter A; de Jong, Marion
2016-12-01
Targeted alpha therapy has been postulated to have great potential for the treatment of small clusters of tumour cells as well as small metastases. (213)Bismuth, an α-emitter with a half-life of 46 min, has shown to be effective in preclinical as well as in clinical applications. In this study, we evaluated whether (213)Bi-[DOTA(0), Tyr(3)]-octreotate ((213)Bi-DOTATATE), a (213)Bi-labelled somatostatin analogue with high affinity for somatostatin receptor subtype 2 (SSTR2), is suitable for the treatment of larger neuroendocrine tumours overexpressing SSTR2 in comparison to its effectiveness for smaller tumours. We performed a preclinical targeted radionuclide therapy study with (213)Bi-DOTATATE in animals bearing tumours of different sizes (50 and 200 mm(3)) using two tumour models: H69 (human small cell lung carcinoma) and CA20948 (rat pancreatic tumour). Pharmacokinetics was determined for calculation of dosimetry in organs and tumours. H69- or CA20948-xenografted mice with tumour volumes of approximately 120 mm(3) were euthanized at 10, 30, 60 and 120 min post injection of a single dose of (213)Bi-DOTATATE (1.5-4.8 MBq). To investigate the therapeutic efficacy of (213)Bi-DOTATATE, xenografted H69 and CA20948 tumour-bearing mice with tumour sizes of 50 and 200 mm(3) were administered daily with a therapeutic dose of (213)Bi-DOTATATE (0.3 nmol, 2-4 MBq) for three consecutive days. The animals were followed for 90 days after treatment. At day 90, mice were injected with 25 MBq (99m)Tc-DMSA and imaged by SPECT/CT to investigate possible renal dysfunction due to (213)Bi-DOTATATE treatment. Higher tumour uptakes were found in CA20948 tumour-bearing animals compared to those in H69 tumour-bearing mice with the highest tumour uptake of 19.6 ± 6.6 %IA/g in CA20948 tumour-bearing animals, while for H69 tumour-bearing mice, the highest tumour uptake was found to be 9.8 ± 2.4 %IA/g. Nevertheless, as the anti-tumour effect was more pronounced in H69 tumour-bearing mice, the survival rate was higher. Furthermore, in the small tumour groups, no regrowth of tumour was found in two H69 tumour-bearing mice and in one of the CA20948 tumour-bearing mice. No renal dysfunction was observed in (213)Bi-DOTATATE-treated mice after the doses were applied. (213)Bi-DOTATATE demonstrated a great therapeutic effect in both small and larger tumour lesions. Higher probability for stable disease was found in animals with small tumours. (213)Bi-DOTATATE was effective in different neuroendocrine (H69 and CA20948) tumour models with overexpression of SSTR2 in mice.
Dynamic traversal of high bumps and large gaps by a small legged robot
NASA Astrophysics Data System (ADS)
Gart, Sean; Winey, Nastasia; de La Tijera Obert, Rafael; Li, Chen
Small animals encounter and negotiate diverse obstacles comparable in size or larger than themselves. In recent experiments, we found that cockroaches can dynamically traverse bumps up to 4 times hip height and gaps up to 1 body length. To better understand the physics that governs these locomotor transitions, we studied a small six-legged robot negotiating high bumps and large gaps and compared it to animal observations. We found that the robot was able to traverse bumps as large as 1 hip height and gaps as wide as 0.5 body length. For the bump, the robot often climbed over to traverse when initial body yaw was small, but was often deflected laterally and failed to traverse when initial body yaw was large. A simple locomotion energy landscape model explained these observations. For the gap, traversal probability decreased with gap width, which was well explained by a simple Lagrangian model of a forward-moving rigid body falling over the gap edge. For both the bump and the gap, animal performance far exceeded that of the robot, likely due to their relatively higher running speeds and larger rotational oscillations prior to and during obstacle traversal. Differences between animal and robot obstacle negotiation behaviors revealed that animals used active strategies to overcome potential energy barriers.
Rapid Inversion: Running Animals and Robots Swing like a Pendulum under Ledges
Mongeau, Jean-Michel; McRae, Brian; Jusufi, Ardian; Birkmeyer, Paul; Hoover, Aaron M.; Fearing, Ronald; Full, Robert J.
2012-01-01
Escaping from predators often demands that animals rapidly negotiate complex environments. The smallest animals attain relatively fast speeds with high frequency leg cycling, wing flapping or body undulations, but absolute speeds are slow compared to larger animals. Instead, small animals benefit from the advantages of enhanced maneuverability in part due to scaling. Here, we report a novel behavior in small, legged runners that may facilitate their escape by disappearance from predators. We video recorded cockroaches and geckos rapidly running up an incline toward a ledge, digitized their motion and created a simple model to generalize the behavior. Both species ran rapidly at 12–15 body lengths-per-second toward the ledge without braking, dove off the ledge, attached their feet by claws like a grappling hook, and used a pendulum-like motion that can exceed one meter-per-second to swing around to an inverted position under the ledge, out of sight. We discovered geckos in Southeast Asia can execute this escape behavior in the field. Quantification of these acrobatic behaviors provides biological inspiration toward the design of small, highly mobile search-and-rescue robots that can assist us during natural and human-made disasters. We report the first steps toward this new capability in a small, hexapedal robot. PMID:22701594
Fluorescence diffuse tomography for detection of RFP-expressed tumors in small animals
NASA Astrophysics Data System (ADS)
Turchin, Ilya V.; Savitsky, Alexander P.; Kamensky, Vladislav A.; Plehanov, Vladimir I.; Meerovich, Irina G.; Arslanbaeva, Lyaisan R.; Jerdeva, Viktoria V.; Orlova, Anna G.; Kleshnin, Mikhail S.; Shirmanova, Marina V.; Fiks, Ilya I.
2007-02-01
Conventional optical imaging is restricted with tumor size due to high tissue scattering. Labeling of tumors by fluorescent markers improves sensitivity of tumor detection thus increasing the value of optical imaging dramatically. Creation of tumor cell lines transfected with fluorescent proteins gives the possibility not only to detect tumor, but also to conduct the intravital monitoring studies. Cell lines of human melanomas Mel-P, Mel-Kor and human embryonic kidney HEK-293 Phoenix were transfected with DsRed-Express and TurboRFP genes. Emission of RFP in the long-wave optical range permits detection of the deeply located tumors, which is essential for whole-body imaging. Only special tools for turbid media imaging, such as fluorescent diffusion tomography (FDT), enable noninvasive investigation of the internal structure of biological tissue. FDT setup for monitoring of tumor growth in small animals has been created. An animal is scanned in the transilluminative configuration by low-frequency modulated light (1 kHz) from Nd:YAG laser with second harmonic generation at the 532 nm wavelength. In vivo experiments were conducted immediately after the subcutaneously injection of fluorescing cells into small animals. It was shown that FDT method allows to detect the presence of fluorescent cells in small animals and can be used for monitoring of tumor growth and anticancer drug responce.
Grönlund Andersson, Ulrika; Wallensten, Anders; Hæggman, Sara; Greko, Christina; Hedin, Göran; Hökeberg, Ingegerd; Lindström, Fredrik; Olsson-Liljequist, Barbro; Smedjegård, Jan; Söderblom, Tomas; Windahl, Ulrika; Struwe, Johan
2014-04-01
Methicillin-resistant Staphylococcus aureus (MRSA) was found in a dog for the first time in Sweden in 2006. Between October 2006 and May 2007, MRSA was diagnosed in 7 more dogs that had been treated in 3 different small animal hospitals, located 150-200 km apart, in different counties of Sweden. Screening of the animal hospital staff and environment in these small animal hospitals showed 20 of 152 staff to be positive for MRSA, with rates between 2% and 18% in the different hospitals, while all 128 environmental samples were negative. All MRSA isolates from dogs and staff belonged to spa type t032, were Panton-Valentine leukocidin (PVL)-negative, and had indistinguishable pulsed-field gel electrophoresis patterns, except for 2 isolates with closely related patterns. To our knowledge, this is the first report of multiple outbreaks of MRSA in dogs caused by the same strain within a short time frame, and appearing in a country with low prevalence of MRSA in both humans and dogs. This highlights the importance of infection control programs in animal hospitals and in animal health care. Awareness of MRSA as an occupational risk for veterinary personnel is essential.
A dual RF resonator system for high-field functional magnetic resonance imaging of small animals.
Ludwig, R; Bodgdanov, G; King, J; Allard, A; Ferris, C F
2004-01-30
A new apparatus has been developed that integrates an animal restrainer arrangement for small animals with an actively tunable/detunable dual radio-frequency (RF) coil system for in vivo anatomical and functional magnetic resonance imaging of small animals at 4.7 T. The radio-frequency coil features an eight-element microstrip line configuration that, in conjunction with a segmented outer copper shield, forms a transversal electromagnetic (TEM) resonator structure. Matching and active tuning/detuning is achieved through fixed/variable capacitors and a PIN diode for each resonator element. These components along with radio-frequency chokes (RFCs) and blocking capacitors are placed on two printed circuit boards (PCBs) whose copper coated ground planes form the front and back of the volume coil and are therefore an integral part of the resonator structure. The magnetic resonance signal response is received with a dome-shaped single-loop surface coil that can be height-adjustable with respect to the animal's head. The conscious animal is immobilized through a mechanical arrangement that consists of a Plexiglas body tube and a head restrainer. This restrainer has a cylindrical holder with a mouthpiece and position screws to receive and restrain the head of the animal. The apparatus is intended to perform anatomical and functional magnetic resonance imaging in conscious animals such as mice, rats, hamsters, and marmosets. Cranial images acquired from fully conscious rats in a 4.7 T Bruker 40 cm bore animal scanner underscore the feasibility of this approach and bode well to extend this system to the imaging of other animals.
Management of occupational health risks in small-animal veterinary practices.
D'Souza, Eva; Barraclough, Richard; Fishwick, David; Curran, Andrew
2009-08-01
Small-animal work is a major element of veterinary practice in the UK and may be hazardous, with high levels of work-related injuries and ill-health reported in Australia and USA. There are no studies addressing the management of occupational health risks arising from small-animal work in the UK. To investigate the sources of health and safety information used and how health and safety and 12 specific occupational health risks are managed by practices. A cross-sectional postal survey of all small-animal veterinary practices in Hampshire. A response was mandatory as this was a Health & Safety Executive (HSE) inspection activity. A total of 118 (100%) practices responded of which 93 were eligible for inclusion. Of these, 99 and 86%, respectively, were aware of the Royal College of Veterinary Surgeons (RCVS) practice standards and had British Small Animal Veterinary Association (BSAVA) staff members, while only 51% had previous contact with HSE (publications, advice and visit). Ninety per cent had health and safety policies, but only 31% had trained responsible staff in health and safety. Specific health hazards such as occupational allergens and computer use were relatively overlooked both by practices and the RCVS/BSAVA guidance available in 2002. Failings in active health risk management systems could be due to a lack of training to ensure competence in those with responsibilities. Practices rely on guidance produced by their professional bodies. Current RCVS guidance, available since 2005, has remedied some previous omissions, but further improvements are recommended.
Microbial agents in macroscopically healthy mammary gland tissues of small ruminants.
Spuria, Liliana; Biasibetti, Elena; Bisanzio, Donal; Biasato, Ilaria; De Meneghi, Daniele; Nebbia, Patrizia; Robino, Patrizia; Bianco, Paolo; Lamberti, Michele; Caruso, Claudio; Di Blasio, Alessia; Peletto, Simone; Masoero, Loretta; Dondo, Alessandro; Capucchio, Maria Teresa
2017-01-01
Health of mammary glands is fundamental for milk and dairy products hygiene and quality, with huge impacts on consumers welfare. This study aims to investigate the microbial agents (bacteria, fungi and lentiviruses) isolated from 89 macroscopically healthy udders of regularly slaughtered small ruminants (41 sheep, 48 goats), also correlating their presence with the histological findings. Multinomial logistic regression was applied to evaluate the association between lesions and positivity for different microbial isolates, animal age and bacteria. Twenty-five samples were microbiologically negative; 138 different bacteria were isolated in 64 positive udders. Coagulase-negative staphylococci were the most prevalent bacteria isolated (46.42%), followed by environmental opportunists (34.76%), others (10.14%) and pathogens (8.68%). Most mammary glands showed coinfections (75%). Lentiviruses were detected in 39.3% of samples. Histologically, chronic non-suppurative mastitis was observed in 45/89 glands, followed by chronic mixed mastitis (12/89) and acute suppurative mastitis (4/89). Only 28 udders were normal. Histological lesions were significantly associated with the animal species and lentiviruses and coagulase-negative staphylococci infections. Goats had significantly higher risk to show chronic mixed mastitis compared to sheep. Goats showed a significantly lower risk (OR = 0.26; 95% CI [0.06-0.71]) of being infected by environmental opportunists compared to sheep, but higher risk (OR = 10.87; 95% CI [3.69-37.77]) of being infected with lentiviruses. The results of the present study suggest that macroscopically healthy glands of small ruminants could act as a reservoir of microbial agents for susceptible animals, representing a potential risk factor for the widespread of acute or chronic infection in the flock.
NASA Astrophysics Data System (ADS)
Liu, Jingfei; Foiret, Josquin; Stephens, Douglas N.; Le Baron, Olivier; Ferrara, Katherine W.
2016-07-01
A 1.5 MHz prolate spheroidal therapeutic array with 128 circular elements was designed to accommodate standard imaging arrays for ultrasonic image-guided hyperthermia. The implementation of this dual-array system integrates real-time therapeutic and imaging functions with a single ultrasound system (Vantage 256, Verasonics). To facilitate applications involving small animal imaging and therapy the array was designed to have a beam depth of field smaller than 3.5 mm and to electronically steer over distances greater than 1 cm in both the axial and lateral directions. In order to achieve the required f number of 0.69, 1-3 piezocomposite modules were mated within the transducer housing. The performance of the prototype array was experimentally evaluated with excellent agreement with numerical simulation. A focal volume (2.70 mm (axial) × 0.65 mm (transverse) × 0.35 mm (transverse)) defined by the -6 dB focal intensity was obtained to address the dimensions needed for small animal therapy. An electronic beam steering range defined by the -3 dB focal peak intensity (17 mm (axial) × 14 mm (transverse) × 12 mm (transverse)) and -8 dB lateral grating lobes (24 mm (axial) × 18 mm (transverse) × 16 mm (transverse)) was achieved. The combined testing of imaging and therapeutic functions confirmed well-controlled local heating generation and imaging in a tissue mimicking phantom. This dual-array implementation offers a practical means to achieve hyperthermia and ablation in small animal models and can be incorporated within protocols for ultrasound-mediated drug delivery.
Liu, Jingfei; Foiret, Josquin; Stephens, Douglas N; Le Baron, Olivier; Ferrara, Katherine W
2016-07-21
A 1.5 MHz prolate spheroidal therapeutic array with 128 circular elements was designed to accommodate standard imaging arrays for ultrasonic image-guided hyperthermia. The implementation of this dual-array system integrates real-time therapeutic and imaging functions with a single ultrasound system (Vantage 256, Verasonics). To facilitate applications involving small animal imaging and therapy the array was designed to have a beam depth of field smaller than 3.5 mm and to electronically steer over distances greater than 1 cm in both the axial and lateral directions. In order to achieve the required f number of 0.69, 1-3 piezocomposite modules were mated within the transducer housing. The performance of the prototype array was experimentally evaluated with excellent agreement with numerical simulation. A focal volume (2.70 mm (axial) × 0.65 mm (transverse) × 0.35 mm (transverse)) defined by the -6 dB focal intensity was obtained to address the dimensions needed for small animal therapy. An electronic beam steering range defined by the -3 dB focal peak intensity (17 mm (axial) × 14 mm (transverse) × 12 mm (transverse)) and -8 dB lateral grating lobes (24 mm (axial) × 18 mm (transverse) × 16 mm (transverse)) was achieved. The combined testing of imaging and therapeutic functions confirmed well-controlled local heating generation and imaging in a tissue mimicking phantom. This dual-array implementation offers a practical means to achieve hyperthermia and ablation in small animal models and can be incorporated within protocols for ultrasound-mediated drug delivery.
High Resolution PET with 250 micrometer LSO Detectors and Adaptive Zoom
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cherry, Simon R.; Qi, Jinyi
2012-01-08
There have been impressive improvements in the performance of small-animal positron emission tomography (PET) systems since their first development in the mid 1990s, both in terms of spatial resolution and sensitivity, which have directly contributed to the increasing adoption of this technology for a wide range of biomedical applications. Nonetheless, current systems still are largely dominated by the size of the scintillator elements used in the detector. Our research predicts that developing scintillator arrays with an element size of 250 {micro}m or smaller will lead to an image resolution of 500 {micro}m when using 18F- or 64Cu-labeled radiotracers, giving amore » factor of 4-8 improvement in volumetric resolution over the highest resolution research systems currently in existence. This proposal had two main objectives: (i) To develop and evaluate much higher resolution and efficiency scintillator arrays that can be used in the future as the basis for detectors in a small-animal PET scanner where the spatial resolution is dominated by decay and interaction physics rather than detector size. (ii) To optimize one such high resolution, high sensitivity detector and adaptively integrate it into the existing microPET II small animal PET scanner as a 'zoom-in' detector that provides higher spatial resolution and sensitivity in a limited region close to the detector face. The knowledge gained from this project will provide valuable information for building future PET systems with a complete ring of very high-resolution detector arrays and also lay the foundations for utilizing high-resolution detectors in combination with existing PET systems for localized high-resolution imaging.« less
Viola, M N Paso; Riccialdelli, L; Jaureguizar, A; Panarello, H O; Cappozzo, H L
2018-05-01
The aim of this study was to analyze the isotopic composition in muscle of striped weakfish Cynoscion guatucupa from Southwest Atlantic Ocean in order to evaluate a possible variation in δ13C and δ15N in response to dietary shifts that occur as animals grow. We also explored for isotopic evidence of differences between sample locations. The results showed an agreement between isotope analysis and previous conventional studies. Differences in the isotope composition between sampling location were not observed. A positive relation exists between isotope values and total body length of the animals. The Cluster analysis defined three groups of size classes, validated by the MDS. Differences in the relative consumption of prey species in each size class were also observed performing isotope mixing models (SIAR). Variation in δ15N among size classes would be associated with the consumption of a different type of prey as animals grow. Small striped weakfish feed on small crustaceans and progressively increase their consumption of fish (anchovy, Engraulis anchoita), increasing by this way their isotope values. On the other hand, differences in δ13C values seemed to be related to age-class specific spatial distribution patterns. Therefore, large and small striped weakfish remain specialized but feeding on different prey at different trophic levels. These results contribute to the study of the diet of striped weakfish, improve the isotopic ecology models and highlight on the importance of accounting for variation in the isotopic composition in response to dietary shifts with the size of one of the most important fishery resources in the region.
Soler, Carles; Contell, Jesús; Bori, Lorena; Sancho, María; García-Molina, Almudena; Valverde, Anthony; Segarvall, Jan
2017-01-01
This work provides information on the blue fox ejaculated sperm quality needed for seminal dose calculations. Twenty semen samples, obtained by masturbation, were analyzed for kinematic and morphometric parameters by using CASA-Mot and CASA-Morph system and principal component (PC) analysis. For motility, eight kinematic parameters were evaluated, which were reduced to PC1, related to linear variables, and PC2, related to oscillatory movement. The whole population was divided into three independent subpopulations: SP1, fast cells with linear movement; SP2, slow cells and nonoscillatory motility; and SP3, medium speed cells and oscillatory movement. In almost all cases, the subpopulation distribution by animal was significantly different. Head morphology analysis generated four size and four shape parameters, which were reduced to PC1, related to size, and PC2, related to shape of the cells. Three morphometric subpopulations existed: SP1: large oval cells; SP2: medium size elongated cells; and SP3: small and short cells. The subpopulation distribution differed between animals. Combining the kinematic and morphometric datasets produced PC1, related to morphometric parameters, and PC2, related to kinematics, which generated four sperm subpopulations - SP1: high oscillatory motility, large and short heads; SP2: medium velocity with small and short heads; SP3: slow motion small and elongated cells; and SP4: high linear speed and large elongated cells. Subpopulation distribution was different in all animals. The establishment of sperm subpopulations from kinematic, morphometric, and combined variables not only improves the well-defined fox semen characteristics and offers a good conceptual basis for fertility and sperm preservation techniques in this species, but also opens the door to use this approach in other species, included humans.
Soler, Carles; Contell, Jesús; Bori, Lorena; Sancho, María; García-Molina, Almudena; Valverde, Anthony; Segarvall, Jan
2017-01-01
This work provides information on the blue fox ejaculated sperm quality needed for seminal dose calculations. Twenty semen samples, obtained by masturbation, were analyzed for kinematic and morphometric parameters by using CASA-Mot and CASA-Morph system and principal component (PC) analysis. For motility, eight kinematic parameters were evaluated, which were reduced to PC1, related to linear variables, and PC2, related to oscillatory movement. The whole population was divided into three independent subpopulations: SP1, fast cells with linear movement; SP2, slow cells and nonoscillatory motility; and SP3, medium speed cells and oscillatory movement. In almost all cases, the subpopulation distribution by animal was significantly different. Head morphology analysis generated four size and four shape parameters, which were reduced to PC1, related to size, and PC2, related to shape of the cells. Three morphometric subpopulations existed: SP1: large oval cells; SP2: medium size elongated cells; and SP3: small and short cells. The subpopulation distribution differed between animals. Combining the kinematic and morphometric datasets produced PC1, related to morphometric parameters, and PC2, related to kinematics, which generated four sperm subpopulations – SP1: high oscillatory motility, large and short heads; SP2: medium velocity with small and short heads; SP3: slow motion small and elongated cells; and SP4: high linear speed and large elongated cells. Subpopulation distribution was different in all animals. The establishment of sperm subpopulations from kinematic, morphometric, and combined variables not only improves the well-defined fox semen characteristics and offers a good conceptual basis for fertility and sperm preservation techniques in this species, but also opens the door to use this approach in other species, included humans. PMID:27751987
[Cases of suspected poisoning in small animal practice - a retrospective and prospective survey].
Allkämper, Svenja; Kösters, Sarah; Campe, Amely; Kietzmann, Manfred; Kreienbrock, Lothar
2018-06-01
Systematic survey of data from cases of suspected poisoning in small animal practices. In 11 exemplary selected small animal practices, patient files from cases of suspected poisoning over 2006/2007, data entry forms of poisonings 2009-2010 and the contact group, which are all patients with at least one visit in 2007, were analysed. In 2007, approximately 1 in 200 dog and 1 in 500 cat patients were presented with poisoning. More than 70 % of cases concerned dogs. Some breeds of hunting dogs were more frequently affected than expected from their percentage in the practice population. Suspicion of poisoning was retrospective mainly founded in neutered dogs. In addition to numerous unspecific symptoms, bleeding was frequently observed. With central nervous system symptoms or a critical general condition a founded suspicion was observed more frequently. In cases of unfounded suspicion, inflammation of the gastrointestinal tract was mostly present. Other frequently seen diseases were infections, tumours and autoimmune diseases. The main toxins in the retrospective evaluation were coumarin derivatives (37 %), drugs (10 %) and chocolate (7 %). The prospective survey yielded a higher percentage of poisoning with drugs and plants. The diagnosis was mainly based on case history and clinical signs. Therapy was predominantly symptomatic. Poisoning with coumarin derivatives is the most frequent intoxication in dogs, but also cats. The risk from permethrin for cats remains current. In daily practice, therapy is mostly symptomatic without any specific toxicological evidence. Consequently, the causative toxin is frequently unknown. Therefore, additional methods for elimination (stomach/rectal lavage, medical coal, lipid therapy) should be included as therapeutical options. For a successful systematic prospective survey in daily practice a good collaboration between practice and investigator is necessary. Schattauer GmbH.
NASA Astrophysics Data System (ADS)
McDougald, Wendy A.; Collins, Richard; Green, Mark; Tavares, Adriana A. S.
2017-10-01
Obtaining accurate quantitative measurements in preclinical Positron Emission Tomography/Computed Tomography (PET/CT) imaging is of paramount importance in biomedical research and helps supporting efficient translation of preclinical results to the clinic. The purpose of this study was two-fold: (1) to investigate the effects of different CT acquisition protocols on PET/CT image quality and data quantification; and (2) to evaluate the absorbed dose associated with varying CT parameters. Methods: An air/water quality control CT phantom, tissue equivalent material phantom, an in-house 3D printed phantom and an image quality PET/CT phantom were imaged using a Mediso nanoPET/CT scanner. Collected data was analyzed using PMOD software, VivoQuant software and National Electric Manufactures Association (NEMA) software implemented by Mediso. Measured Hounsfield Unit (HU) in collected CT images were compared to the known HU values and image noise was quantified. PET recovery coefficients (RC), uniformity and quantitative bias were also measured. Results: Only less than 2% and 1% of CT acquisition protocols yielded water HU values < -80 and air HU values < -840, respectively. Four out of eleven CT protocols resulted in more than 100 mGy absorbed dose. Different CT protocols did not impact PET uniformity and RC, and resulted in <4% overall bias relative to expected radioactive concentration. Conclusion: Preclinical CT protocols with increased exposure times can result in high absorbed doses to the small animals. These should be avoided, as they do not contributed towards improved microPET/CT image quantitative accuracy and could limit longitudinal scanning of small animals.
TH-EF-207A-05: Feasibility of Applying SMEIR Method On Small Animal 4D Cone Beam CT Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhong, Y; Zhang, Y; Shao, Y
Purpose: Small animal cone beam CT imaging has been widely used in preclinical research. Due to the higher respiratory rate and heat beats of small animals, motion blurring is inevitable and needs to be corrected in the reconstruction. Simultaneous motion estimation and image reconstruction (SMEIR) method, which uses projection images of all phases, proved to be effective in motion model estimation and able to reconstruct motion-compensated images. We demonstrate the application of SMEIR for small animal 4D cone beam CT imaging by computer simulations on a digital rat model. Methods: The small animal CBCT imaging system was simulated with themore » source-to-detector distance of 300 mm and the source-to-object distance of 200 mm. A sequence of rat phantom were generated with 0.4 mm{sup 3} voxel size. The respiratory cycle was taken as 1.0 second and the motions were simulated with a diaphragm motion of 2.4mm and an anterior-posterior expansion of 1.6 mm. The projection images were calculated using a ray-tracing method, and 4D-CBCT were reconstructed using SMEIR and FDK methods. The SMEIR method iterates over two alternating steps: 1) motion-compensated iterative image reconstruction by using projections from all respiration phases and 2) motion model estimation from projections directly through a 2D-3D deformable registration of the image obtained in the first step to projection images of other phases. Results: The images reconstructed using SMEIR method reproduced the features in the original phantom. Projections from the same phase were also reconstructed using FDK method. Compared with the FDK results, the images from SMEIR method substantially improve the image quality with minimum artifacts. Conclusion: We demonstrate that it is viable to apply SMEIR method to reconstruct small animal 4D-CBCT images.« less
NASA Astrophysics Data System (ADS)
Konik, Arda; Madsen, Mark T.; Sunderland, John J.
2012-10-01
In human emission tomography, combined PET/CT and SPECT/CT cameras provide accurate attenuation maps for sophisticated scatter and attenuation corrections. Having proven their potential, these scanners are being adapted for small animal imaging using similar correction approaches. However, attenuation and scatter effects in small animal imaging are substantially less than in human imaging. Hence, the value of sophisticated corrections is not obvious for small animal imaging considering the additional cost and complexity of these methods. In this study, using GATE Monte Carlo package, we simulated the Inveon small animal SPECT (single pinhole collimator) scanner to find the scatter fractions of various sizes of the NEMA-mouse (diameter: 2-5.5 cm , length: 7 cm), NEMA-rat (diameter: 3-5.5 cm, length: 15 cm) and MOBY (diameter: 2.1-5.5 cm, length: 3.5-9.1 cm) phantoms. The simulations were performed for three radionuclides commonly used in small animal SPECT studies:99mTc (140 keV), 111In (171 keV 90% and 245 keV 94%) and 125I (effective 27.5 keV). For the MOBY phantoms, the total Compton scatter fractions ranged (over the range of phantom sizes) from 4-10% for 99mTc (126-154 keV), 7-16% for 111In (154-188 keV), 3-7% for 111In (220-270 keV) and 17-30% for 125I (15-45 keV) including the scatter contributions from the tungsten collimator, lead shield and air (inside and outside the camera heads). For the NEMA-rat phantoms, the scatter fractions ranged from 10-15% (99mTc), 17-23% 111In: 154-188 keV), 8-12% (111In: 220-270 keV) and 32-40% (125I). Our results suggest that energy window methods based on solely emission data are sufficient for all mouse and most rat studies for 99mTc and 111In. However, more sophisticated methods may be needed for 125I.
Agrawal, Priyanka; Soni, Sandeep; Mittal, Gaurav; Bhatnagar, Aseem
2015-01-01
Sildenafil citrate (SC) nebulization solution has the potential to treat pulmonary hypertension by delivering high concentration directly to the respiratory system while minimizing systemic drug exposure and associated toxicity. The objective of the present study was to evaluate the potential toxicity of aerosolized SC (inhaled) in Sprague dawley rats for 28 days. The rats were randomly divided into five groups (n = 6). Placebo (normal saline) was inhaled to group I (control). Group II was exposed to therapeutic dose (TD): 20 mg/kg, while group 3 and group 4 were exposed to 3 TD and 6 TD, respectively, till 28 days and toxicokinetic parameters were evaluated in group V. The particle size of the nebulized solution of SC (1%) was measured by using Anderson Cascade Impactor. At the end of experiment, all animals were sacrificed. Endpoints used to evaluate potential toxicity of inhaled sildenafil citrate were clinical observations, body weight, and clinical pathology along with broncho-alveolar lavage (BAL) Fluid investigation. ACI study has shown that more than 70% aerosolized drug particles were in submicron range (0.3-0.5 μm). There was no systemic toxicity or clinically limiting local respiratory toxicity associated with inhalation exposure to SC nebulization solution at 6 TD. No significant changes were observed in the level of different blood and BALF parameters in treated groups in comparison to control. Histopathological examination revealed no abnormal findings in the animals of treated group. The data demonstrate that aerosolized sildenafil citrate is well tolerated in rats and suggest its use in humans.
Valverde, Anthony; Arenán, Héctor; Sancho, María; Contell, Jesús; Yániz, Jesús; Fernández, Alejandro; Soler, Carles
2016-01-01
Sperm quality is evaluated for the calculation of sperm dosage in artificial reproductive programs. The most common parameter used is motility, but morphology has a higher potential as a predictor of genetic quality. Morphometry calculations from CASA-Morph technology improve morphological evaluation and allow mathematical approaches to the problem. Semen from 28 Holstein bulls was collected by artificial vagina, and several ejaculates were studied. After general evaluation, samples were diluted, packaged in 0.25 ml straws, and stored in liquid nitrogen. Two straws per sample were thawed, and slides were processed and stained with Diff-Quik. Samples were analyzed by a CASA-Morph system for eight morphometric parameters. In addition to the “classical” statistical approach, based on variance analysis (revealing differences between animals, ejaculates, and straws), principal component (PC) analysis showed that the variables were grouped into PC1, related to size, and PC2 to shape. Subpopulation structure analysis showed four groups, namely, big, small, short, and narrow from their dominant characteristics, representing 31.0%, 27.3%, 24.1%, and 17.7% of the total population, respectively. The distributions varied between animals and ejaculates, but between straws, there were no differences in only four animals. This modern approach of considering an ejaculate sperm population as divided into subpopulations reflecting quantifiable parameters generated by CASA-Morph systems technology opens a new view on sperm function. This is the first study applying this approach to evaluate different ejaculates and straws from the same individual. More work must be done to improve seminal dose calculations in assisted reproductive programs. PMID:27678464
Valverde, Anthony; Arenán, Héctor; Sancho, María; Contell, Jesús; Yániz, Jesús; Fernández, Alejandro; Soler, Carles
2016-01-01
Sperm quality is evaluated for the calculation of sperm dosage in artificial reproductive programs. The most common parameter used is motility, but morphology has a higher potential as a predictor of genetic quality. Morphometry calculations from CASA-Morph technology improve morphological evaluation and allow mathematical approaches to the problem. Semen from 28 Holstein bulls was collected by artificial vagina, and several ejaculates were studied. After general evaluation, samples were diluted, packaged in 0.25 ml straws, and stored in liquid nitrogen. Two straws per sample were thawed, and slides were processed and stained with Diff-Quik. Samples were analyzed by a CASA-Morph system for eight morphometric parameters. In addition to the "classical" statistical approach, based on variance analysis (revealing differences between animals, ejaculates, and straws), principal component (PC) analysis showed that the variables were grouped into PC1, related to size, and PC2 to shape. Subpopulation structure analysis showed four groups, namely, big, small, short, and narrow from their dominant characteristics, representing 31.0%, 27.3%, 24.1%, and 17.7% of the total population, respectively. The distributions varied between animals and ejaculates, but between straws, there were no differences in only four animals. This modern approach of considering an ejaculate sperm population as divided into subpopulations reflecting quantifiable parameters generated by CASA-Morph systems technology opens a new view on sperm function. This is the first study applying this approach to evaluate different ejaculates and straws from the same individual. More work must be done to improve seminal dose calculations in assisted reproductive programs.
Irradiation-hyperthermia in canine hemangiopericytomas: large-animal model for therapeutic response.
Richardson, R C; Anderson, V L; Voorhees, W D; Blevins, W E; Inskeep, T K; Janas, W; Shupe, R E; Babbs, C F
1984-11-01
Results of irradiation-hyperthermia treatment in 11 dogs with naturally occurring hemangiopericytoma were reported. Similarities of canine and human hemangiopericytomas were described. Orthovoltage X-irradiation followed by microwave-induced hyperthermia resulted in a 91% objective response rate. A statistical procedure was given to evaluate quantitatively the clinical behavior of locally invasive, nonmetastatic tumors in dogs that were undergoing therapy for control of local disease. The procedure used a small sample size and demonstrated distribution of the data on a scaled response as well as transformation of the data through classical parametric and nonparametric statistical methods. These statistical methods set confidence limits on the population mean and placed tolerance limits on a population percentage. Application of the statistical methods to human and animal clinical trials was apparent.
Raben, David; Bianco, Cataldo; Damiano, Vincenzo; Bianco, Roberto; Melisi, Davide; Mignogna, Chiara; D'Armiento, Francesco Paolo; Cionini, Luca; Bianco, A Raffaele; Tortora, Giampaolo; Ciardiello, Fortunato; Bunn, Paul
2004-08-01
Targeting the tumor vasculature may offer an alternative or complementary therapeutic approach to targeting growth factor signaling in lung cancer. The aim of these studies was to evaluate the antitumor effects in vivo of the combination of ZD6126, a tumor-selective vascular-targeting agent; ZD1839 (gefitinib, Iressa), an epidermal growth factor receptor tyrosine kinase inhibitor; and ionizing radiation in the treatment of non-small cell lung cancer xenograft model. Athymic nude mice with established flank A549 human non-small cell lung cancer xenograft model xenografts were treated with fractionated radiation therapy, ZD6126, ZD1839, or combinations of each treatment. ZD6126 (150 mg/kg) was given i.p. the day after each course of radiation. Animals treated with ZD1839 received 100 mg/kg per dose per animal, 5 or 7 days/wk for 2 weeks. Immunohistochemistry was done to evaluate the effects on tumor growth using an anti-Ki67 monoclonal antibody. Effects on tumor-induced vascularization were quantified using an anti-factor VIII-related antigen monoclonal antibody. ZD6126 attenuated the growth of human A549 flank xenografts compared with untreated animals. Marked antitumor effects were observed when animals were treated with a combination of ZD6126 and fractionated radiation therapy with protracted tumor regression. ZD6126 + ZD1839 resulted in a greater tumor growth delay than either agent alone. Similar additive effects were seen with ZD1839 + fractionated radiation. Finally, the addition of ZD6126 to ZD1839 and radiation therapy seemed to further improve tumor growth control, with a significant tumor growth delay compared with animals treated with single agent or with double combinations. Immunohistochemistry showed that ZD1839 induced a marked reduction in A549 tumor cell proliferation. Both ZD1839 and ZD6126 treatment substantially reduced tumor-induced angiogenesis. ZD6126 caused marked vessel destruction through loss of endothelial cells and thrombosis, substantially increasing the level of necrosis seen when combined with radiation therapy. The combination of radiation therapy, ZD6126, and ZD1839 induced the greatest effects on tumor growth and angiogenesis. This first report shows that a selective vascular-targeting agent (ZD6126) + an anti-epidermal growth factor receptor agent (ZD1839) and radiation have additive in vivo effects in a human cancer model. Targeting the tumor vasculature offers an excellent strategy to enhance radiation cytotoxicity. Polytargeted therapy with agents that interfere with both growth factor and angiogenic signaling warrants further investigation.
Anatomy, pathology, and physiology of the tracheobronchial tree: emphasis on the distal airways.
Hyde, Dallas M; Hamid, Qutayba; Irvin, Charles G
2009-12-01
This article covers the airway tree with respect to anatomy, pathology, and physiology. The anatomic portion discusses various primate groups so as to help investigators understand similarities and differences between animal models. An emphasis is on distal airway findings. The pathology section focuses on the inflammatory responses that occur in proximal and distal airways. The physiologic review brings together the anatomic and pathologic components to the functional state and proposes ways to evaluate the small airways in patients with asthma.
Electron-tracking Compton gamma-ray camera for small animal and phantom imaging
NASA Astrophysics Data System (ADS)
Kabuki, Shigeto; Kimura, Hiroyuki; Amano, Hiroo; Nakamoto, Yuji; Kubo, Hidetoshi; Miuchi, Kentaro; Kurosawa, Shunsuke; Takahashi, Michiaki; Kawashima, Hidekazu; Ueda, Masashi; Okada, Tomohisa; Kubo, Atsushi; Kunieda, Etuso; Nakahara, Tadaki; Kohara, Ryota; Miyazaki, Osamu; Nakazawa, Tetsuo; Shirahata, Takashi; Yamamoto, Etsuji; Ogawa, Koichi; Togashi, Kaori; Saji, Hideo; Tanimori, Toru
2010-11-01
We have developed an electron-tracking Compton camera (ETCC) for medical use. Our ETCC has a wide energy dynamic range (200-1300 keV) and wide field of view (3 sr), and thus has potential for advanced medical use. To evaluate the ETCC, we imaged the head (brain) and bladder of mice that had been administered with F-18-FDG. We also imaged the head and thyroid gland of mice using double tracers of F-18-FDG and I-131 ions.
A new tissue segmentation method to calculate 3D dose in small animal radiation therapy.
Noblet, C; Delpon, G; Supiot, S; Potiron, V; Paris, F; Chiavassa, S
2018-02-26
In pre-clinical animal experiments, radiation delivery is usually delivered with kV photon beams, in contrast to the MV beams used in clinical irradiation, because of the small size of the animals. At this medium energy range, however, the contribution of the photoelectric effect to absorbed dose is significant. Accurate dose calculation therefore requires a more detailed tissue definition because both density (ρ) and elemental composition (Z eff ) affect the dose distribution. Moreover, when applied to cone beam CT (CBCT) acquisitions, the stoichiometric calibration of HU becomes inefficient as it is designed for highly collimated fan beam CT acquisitions. In this study, we propose an automatic tissue segmentation method of CBCT imaging that assigns both density (ρ) and elemental composition (Z eff ) in small animal dose calculation. The method is based on the relationship found between CBCT number and ρ*Z eff product computed from known materials. Monte Carlo calculations were performed to evaluate the impact of ρZ eff variation on the absorbed dose in tissues. These results led to the creation of a tissue database composed of artificial tissues interpolated from tissue values published by the ICRU. The ρZ eff method was validated by measuring transmitted doses through tissue substitute cylinders and a mouse with EBT3 film. Measurements were compared to the results of the Monte Carlo calculations. The study of the impact of ρZ eff variation over the range of materials, from ρZ eff = 2 g.cm - 3 (lung) to 27 g.cm - 3 (cortical bone) led to the creation of 125 artificial tissues. For tissue substitute cylinders, the use of ρZ eff method led to maximal and average relative differences between the Monte Carlo results and the EBT3 measurements of 3.6% and 1.6%. Equivalent comparison for the mouse gave maximal and average relative differences of 4.4% and 1.2%, inside the 80% isodose area. Gamma analysis led to a 94.9% success rate in the 10% isodose area with 4% and 0.3 mm criteria in dose and distance. Our new tissue segmentation method was developed for 40kVp CBCT images. Both density and elemental composition are assigned to each voxel by using a relationship between HU and the product ρZ eff . The method, validated by comparing measurements and calculations, enables more accurate small animal dose distribution calculated on low energy CBCT images.
Role of probiotics in nutrition and health of small ruminants.
Abd El-Tawab, M M; Youssef, I M I; Bakr, H A; Fthenakis, G C; Giadinis, N D
2016-12-01
Small ruminants represent an important economic source in small farm systems and agriculture. Feed is the main component of livestock farming, which has gained special attention to improve animal performance. Many studies have been done to improve feed utilisation through addition of feed additives. For a long period, antibiotics have been widely used as growth promoters in livestock diets. Due to their ban in many countries, search for alternative feed additives has been intensified. Probiotics are one of these alternatives recognised to be safe to the animals. Use of probiotics in small ruminant nutrition has been confirmed to improve animal health, productivity and immunity. Probiotics improved growth performance through enhancing of rumen microbial ecosystem, nutrient digestibility and feed conversion rate. Moreover, probiotics have been reported to stabilise rumen pH, increase volatile fatty acids production and to stimulate lactic acid utilising protozoa, resulting in a highly efficient rumen function. Furthermore, use of probiotics has been found to increase milk production and can reduce incidence of neonatal diarrhea and mortality. However, actual mechanisms through which probiotics exert these functions are not known. Since research on application of probiotics in small ruminants is scarce, the present review attempts to discuss the potential roles of this class of feed additives on productive performance and health status of these animals.
High-resolution short-exposure small-animal laboratory x-ray phase-contrast tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Larsson, Daniel H.; Vågberg, William; Yaroshenko, Andre
X-ray computed tomography of small animals and their organs is an essential tool in basic and preclinical biomedical research. In both phase-contrast and absorption tomography high spatial resolution and short exposure times are of key importance. However, the observable spatial resolutions and achievable exposure times are presently limited by system parameters rather than more fundamental constraints like, e.g., dose. Here we demonstrate laboratory tomography with few-ten μm spatial resolution and few-minute exposure time at an acceptable dose for small-animal imaging, both with absorption contrast and phase contrast. The method relies on a magnifying imaging scheme in combination with a high-powermore » small-spot liquid-metal-jet electron-impact source. Lastly, the tomographic imaging is demonstrated on intact mouse, phantoms and excised lungs, both healthy and with pulmonary emphysema.« less
High-resolution short-exposure small-animal laboratory x-ray phase-contrast tomography
Larsson, Daniel H.; Vågberg, William; Yaroshenko, Andre; ...
2016-12-13
X-ray computed tomography of small animals and their organs is an essential tool in basic and preclinical biomedical research. In both phase-contrast and absorption tomography high spatial resolution and short exposure times are of key importance. However, the observable spatial resolutions and achievable exposure times are presently limited by system parameters rather than more fundamental constraints like, e.g., dose. Here we demonstrate laboratory tomography with few-ten μm spatial resolution and few-minute exposure time at an acceptable dose for small-animal imaging, both with absorption contrast and phase contrast. The method relies on a magnifying imaging scheme in combination with a high-powermore » small-spot liquid-metal-jet electron-impact source. Lastly, the tomographic imaging is demonstrated on intact mouse, phantoms and excised lungs, both healthy and with pulmonary emphysema.« less
NASA Astrophysics Data System (ADS)
Preissner, M.; Murrie, R. P.; Pinar, I.; Werdiger, F.; Carnibella, R. P.; Zosky, G. R.; Fouras, A.; Dubsky, S.
2018-04-01
We have developed an x-ray imaging system for in vivo four-dimensional computed tomography (4DCT) of small animals for pre-clinical lung investigations. Our customized laboratory facility is capable of high resolution in vivo imaging at high frame rates. Characterization using phantoms demonstrate a spatial resolution of slightly below 50 μm at imaging rates of 30 Hz, and the ability to quantify material density differences of at least 3%. We benchmark our system against existing small animal pre-clinical CT scanners using a quality factor that combines spatial resolution, image noise, dose and scan time. In vivo 4DCT images obtained on our system demonstrate resolution of important features such as blood vessels and small airways, of which the smallest discernible were measured as 55–60 μm in cross section. Quantitative analysis of the images demonstrate regional differences in ventilation between injured and healthy lungs.
Small Animal Massage Therapy: A Brief Review and Relevant Observations.
Formenton, Maira Rezende; Pereira, Marco Aurélio Amador; Fantoni, Denise Tabacchi
2017-12-01
Massage therapy is becoming increasingly popular in human and animal physiotherapy and rehabilitation. Wider application of the technique led to research efforts aimed at providing scientific support to anecdotal beneficial effects, particularly pain relief. Recent studies have shown that massage therapy alters dopamine and serotonin levels, decreases noradrenaline levels, and modulates the immune system. Psychological effects such as reduction of stress and anxiety, with improvement of depressive patients, have been reported in humans. This article set out to review the major aspects of massage therapy based on recent publications on the topic, and to extrapolate concepts and practical aspects described in human physiotherapy to the veterinary patient, particularly the applicability of different techniques in Small Animal Medicine. Indications of massage therapy in small animals include pain relief, orthopedic rehabilitation, Canine Sports Medicine, intensive care, and management of nonspecific edema. Techniques described in this article were originally intended for use in humans and scientific data supporting anecdotal, beneficial effects in domestic animals are still lacking; this fruitful area for research is therefore open to veterinary professionals. Copyright © 2017 Elsevier Inc. All rights reserved.
Biological Evaluation of 99mTc-HYNIC-EDDA/tricine-(Ser)-D4 Peptide for Tumor Targeting.
Kazemi, Ziba; Zahmatkesh, Mona Haddad; Abedi, Seyed Mohammad; Hosseinimehr, Seyed Jalal
2017-08-24
D4 small peptide (Leu-Ala-Arg-Leu-Leu-Thr) was selected as an appropriate agent for specific targeting of epidermal growth factor receptor (EGFR). The aim of study was to investigate the 99mTc-labeled D4 peptide for non-small cell lung tumor targeting. HYNIC-(Ser)3-D4 peptide was labeled with 99mTc using mixture of tricine and ethylenediamine diacetic acid (EDDA) as co-ligands. The in vitro cellular uptake of radiolabeled peptide was evaluated by blocking test on human non-small cell lung cancer (A-549) cell line and its biodistribution was evaluated in A-549 xenografted nude mice. This conjugated peptide was labeled with 99mTc in high radiochemical purity and it was highly stable in buffer and serum. The un-blocked to blocked cellular radioactivity ratio was 4- fold that showed a specific binding of this radiolabeled peptide on A-549 cell. Animal biodistribution in A-549 xenografted nude mice showed rapid clearance from blood and other non-target organs. Tumor uptake values as %ID/g (percentage of injection dose per gram of tissue) were 2.47% and 1.30% at 1 and 4 h after injection. This study showed the 99mTc-EDDA/tricine-HYNIC-(Ser)3-D4 peptide had tumor targeting on the non-small cell lung tumor. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
THE SHORT-TERM EFFECTS OF LEAD ON DOMESTIC AND WILD ANIMALS
Small quantities of lead, a ubiquitous and toxic element, may be found in practically all species of plants and animals. The list of animals, both domestic and wild, reportedly intoxicated by lead is impressive. The sources of lead poisoning vary with species of animals. Lead bas...
21 CFR 522.480 - Repository corticotropin injection.
Code of Federal Regulations, 2012 CFR
2012-04-01
... (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS IMPLANTATION OR INJECTABLE DOSAGE FORM NEW ANIMAL DRUGS... refrigerated. With prolonged use supplement daily diet with potassium chloride at one gram for small animals and from 5 to 10 grams for large animals. (4) Conditions of use. (i) It is used as an intramuscular or...
21 CFR 522.480 - Repository corticotropin injection.
Code of Federal Regulations, 2013 CFR
2013-04-01
... (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS IMPLANTATION OR INJECTABLE DOSAGE FORM NEW ANIMAL DRUGS... refrigerated. With prolonged use supplement daily diet with potassium chloride at one gram for small animals and from 5 to 10 grams for large animals. (4) Conditions of use. (i) It is used as an intramuscular or...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marks, Louise, E-mail: louise.marks@astrazeneca.com; Borland, Samantha; Philp, Karen
Despite rigorous preclinical and clinical safety evaluation, adverse cardiac effects remain a leading cause of drug attrition and post-approval drug withdrawal. A number of cardiovascular screens exist within preclinical development. These screens do not, however, provide a thorough cardiac liability profile and, in many cases, are not preventing the progression of high risk compounds. We evaluated the suitability of the anaesthetised guinea-pig for the assessment of drug-induced changes in cardiovascular parameters. Sodium pentobarbitone anaesthetised male guinea-pigs received three 15 minute intravenous infusions of ascending doses of amoxicillin, atenolol, clonidine, dobutamine, dofetilide, flecainide, isoprenaline, levosimendan, milrinone, moxifloxacin, nifedipine, paracetamol, verapamil ormore » vehicle, followed by a 30 minute washout. Dose levels were targeted to cover clinical exposure and above, with plasma samples obtained to evaluate effect/exposure relationships. Arterial blood pressure, heart rate, contractility function (left ventricular dP/dt{sub max} and QA interval) and lead II electrocardiogram were recorded throughout. In general, the expected reference compound induced effects on haemodynamic, contractility and electrocardiographic parameters were detected confirming that all three endpoints can be measured accurately and simultaneously in one small animal. Plasma exposures obtained were within, or close to the expected clinical range of therapeutic plasma levels. Concentration–effect curves were produced which allowed a more complete understanding of the margins for effects at different plasma exposures. This single in vivo screen provides a significant amount of information pertaining to the cardiovascular risk of drug candidates, ultimately strengthening strategies addressing cardiovascular-mediated compound attrition and drug withdrawal. -- Highlights: ► Evaluation of the anaesthetised guinea-pig to determine cardiac liability. ► Haemodynamic, contractility, ECG parameters and plasma exposure all measurable. ► Single small animal model offering extensive evaluation of a drug's CV risk. ► Potential to strengthen drug discovery cardiovascular strategy. ► Potential to halt progression of drugs with CV liability, reducing drug attrition.« less
Marketing small animal theriogenology services--one perspective.
Barber, J A
2007-08-01
Once a decision is made to add small animal theriogenology services to a practice, marketing strategies must be developed and implemented to attract clients to the new services. Marketing strategies for the niche market of theriogenology include start-up marketing methods, referral programs, internal marketing, and continued marketing. Marketing theriogenology services is a dynamic, ongoing process that never ends.
Hollow fiber-optic Raman probes for small experimental animals
NASA Astrophysics Data System (ADS)
Katagiri, Takashi; Hattori, Yusuke; Suzuki, Toshiaki; Matsuura, Yuji; Sato, Hidetoshi
2007-02-01
Two types of hollow fiber-optic probes are developed to measure the in vivo Raman spectra of small animals. One is the minimized probe which is end-sealed with the micro-ball lens. The measured spectra reflect the information of the sample's sub-surface. This probe is used for the measurement of the esophagus and the stomach via an endoscope. The other probe is a confocal Raman probe which consists of a single fiber and a lens system. It is integrated into the handheld microscope. A simple and small multimodal probe is realized because the hollow optical fiber requires no optical filters. The performance of each probe is examined and the effectiveness of these probes for in vivo Raman spectroscopy is shown by animal tests.
Experimental Acquisitions with ^125I on a Small Animal SPECT Device*
NASA Astrophysics Data System (ADS)
Knott, Kevin; Welsh, Robert E.; Bradley, Eric L.; Saha, Margaret S.; Kross, Brian; Majewski, Stan; Popov, Vladimir; Smith, Mark F.; Weisenberger, Andrew G.; Wojcik, Randolph
2001-04-01
We have performed single photon emission computed tomography (SPECT) studies on a small animal scanning system for which the detector employed position sensitive phototubes (125 mm dia. Hamamatsu R3292 and 18 x 18 mm Hamamatsu M-64) coupled to pixelated scintillators CsI(Tl) and CsI(Na) Phantom acquisitions were used to investigate the effects of angular sampling and scan time on reconstructed image quality and noise. Results from these studies will be described and extended to in vivo studies with small animals. *Supported in part by the Thomas F. and Kate Miller Jeffress Trust, the Department of Energy, The American Diabetes Association, The National Science Foundation, the Howard Hughes Foundation and the Virginia Commonwealth Health Research Board.
Mroz, Claudia; Gwida, Mayada; El-Ashker, Maged; El-Diasty, Mohamed; El-Beskawy, Mohamed; Ziegler, Ute; Eiden, Martin; Groschup, Martin H
2017-04-05
Rift Valley fever virus (RVFV) caused several outbreaks throughout the African continent and the Arabian Peninsula posing significant threat to human and animal health. In Egypt the first and most important Rift Valley fever epidemic occurred during 1977/78 with a multitude of infected humans and huge economic losses in livestock. After this major outbreak, RVF epidemics re-occurred in irregular intervals between 1993 and 2003. Seroprevalence of anti-RVFV antibodies in livestock during inter-epidemic periods can be used for supporting the evaluation of the present risk exposure for animal and public health. A serosurvey was conducted during 2014/2015 in non-vaccinated livestock including camels, sheep, goats and buffalos in different areas of the Nile River Delta as well as the furthermost southeast of Egypt to investigate the presence of anti-RVFV antibodies for further evaluating of the risk exposure for animal and human health. All animals integrated in this study were born after the last Egyptian RVF epidemic in 2003 and sampled buffalos and small ruminants were not imported from other endemic countries. A total of 873 serum samples from apparently healthy animals from different host species (camels: n = 221; sheep: n = 438; goats: n = 26; buffalo: n = 188) were tested serologically using RVFV competition ELISA, virus neutralization test and/or an indirect immunofluorescence assay, depending on available serum volume. Sera were assessed positive when virus neutralization test alone or least two assays produced consistent positive results. The overall seroprevalence was 2.29% (95%CI: 1.51-3.07) ranging from 0% in goats, 0.46% in sheep (95%CI: 0.41-0.5), and 3.17% in camels (95%CI: 0.86-5.48) up to 5.85% in buffalos (95%CI: 2.75-8.95). Our findings assume currently low level of circulating virus in the investigated areas and suggest minor indication for a new RVF epidemic. Further the results may indicate that during long inter-epidemic periods, maintenance of the virus occur in vectors and also most probably in buffaloes within cryptic cycle where sporadic, small and local epidemics may occur. Therefore, comprehensive and well-designed surveillance activities are urgently needed to detect first evidence for transition from endemic to epidemic cycle.
Angiogenic effects of borate glass microfibers in a rodent model.
Lin, Yinan; Brown, Roger F; Jung, Steven B; Day, Delbert E
2014-12-01
The primary objective of this research was to evaluate the use of bioactive borate-based glass microfibers for angiogenesis in soft tissue repair applications. The effect of these fibers on growth of capillaries and small blood vessels was compared to that of 45S5 silica glass microfibers and sham implant controls. Compressed mats of three types of glass microfibers were implanted subcutaneously in rats and tissues surrounding the implant sites histologically evaluated 2-4 weeks post surgery. Bioactive borate glass 13-93B3 supplemented with 0.4 wt % copper promoted extensive angiogenesis as compared to silica glass microfibers and sham control tissues. The angiogenic responses suggest the copper-containing 13-93B3 microfibers may be effective for treating chronic soft tissue wounds. A second objective was to assess the possible systemic cytotoxicity of dissolved borate ions and other materials released from implanted borate glass microfibers. Cytotoxicity was assessed via histological evaluation of kidney tissue collected from animals 4 weeks after subcutaneously implanting high amounts of the borate glass microfibers. The evaluation of the kidney tissue from these animals showed no evidence of chronic histopathological changes in the kidney. The overall results indicate the borate glass microfibers are safe and effective for soft tissue applications. © 2014 Wiley Periodicals, Inc.
Marijuana and Breastfeeding: Applicability of the Current Literature to Clinical Practice.
Mourh, Jasminder; Rowe, Hilary
2017-12-01
With recent legalization of marijuana in numerous U.S. states, the risk of marijuana exposure via breast milk is a rising concern. This review analyzes the available human and animal literature regarding maternal use of marijuana during lactation. The findings can be categorized into four areas of analysis: effects of marijuana on the mother, transfer into milk, transfer to the offspring, and effects on the offspring. Human and animal data have reported decreased prolactin levels as well as potential maternal psychological changes. Animal and human studies have reported transfer into milk; levels were detected in animal offspring, and metabolites were excreted by both human and animal offspring. Further, animal data have predominately displayed motor, neurobehavioral, and developmental effects, whereas human data suggested possible psychomotor outcomes; however, some studies reported no effect. Despite these results, many human studies were marred by limitations, including small sample sizes and confounding variables. Also, the applicability of animal data to the human population is questionable and the true risk of adverse effects is not entirely known. There are large gaps in the literature that need to be addressed; in particular, studies need to focus on evaluating the short- and long-term consequences of maternal marijuana use for the infant and the potential for different risks based on the frequency of maternal use. Until further evidence becomes available, practitioners need to weigh the benefits of breastfeeding for mother and child, with the potential influence of marijuana on infant development when determining the infant's most suitable form of nutrition.
ERIC Educational Resources Information Center
Hampson, Michael N.; McCracken, J. David
A study was conducted to identify the skills which are performed and essential for success in seven animal production and management (small animal care) occupations: animal health assistant, laboratory animal assistant, kennel worker, dog groomer, pet shop worker, stable worker, and zoo keeper. Specific objectives were (1) to develop and validate…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pasciak, A; The University of Tennessee Graduate School of Medicine, Knoxville, TN; Nodit, L
Purpose: In Yttrium-90 (90Y) radioembolization, non-target embolization (NTE) to the stomach or small bowel can result in ulceration, a rare but difficult to manage clinical complication. However, dosimetric thresholds for toxicity to these tissues from radioembolization have never been evaluated in a controlled setting. We performed an analysis of the effect of 90Y radioembolization in a porcine model at different absorbed-dose endpoints. Methods: Under approval of the University of Tennessee IACUC, 6 female pigs were included in this study. Animals underwent transfemoral angiography and infusion of calibrated dosages of 90Y resin microspheres into arteries supplying part of the gastric wall.more » A 99mTc-MAA simulation study was performed first to determine perfused tissue volume for treatment planning along with contrast-enhanced CT. The pigs were monitored for side effects for 9 weeks, after which time they were euthanized and their upper gastrointestinal tracts were harvested for analysis. Results: 90Y radioembolization was infused resulting in average absorbed doses of between 35.5 and 91.9 Gy to the gastric wall. No animal exhibited any signs of pain or gastrointestinal distress through the duration of the study. Excised tissue showed 1–2 small (<3.0 cm2) healed or healing superficial gastric lesions in 5 out of 6 animals. Histologic analysis demonstrated that lesion location was superficial to areas of abnormally high microsphere deposition. An analysis of microsphere deposition patterns within the gastric wall indicated a high preference for submucosal deposition. Dosimetric evaluation at the luminal mucosa performed based on microsphere deposition patterns confirmed that 90Y dosimetry techniques conventionally used in hepatic dosimetry provide a reasonable estimate of absorbed dose. Conclusion: The upper gastrointestinal tract may be less sensitive to 90Y radioembolization than previously thought. Lack of charged-particle equilibrium at the luminal mucosa may contribute to decreased toxicity of 90Y radioembolization compared to external-beam radiation therapy in gastrointestinal tissue. This project was supported by SIRTex Medical Ltd.« less
Morel, Nicolás; Signorini, Marcelo L; Mangold, Atilio J; Guglielmone, Alberto A; Nava, Santiago
2017-09-01
The aim of this work was to test the efficacy of strategic control methods of Rhipicephalus microplus infestation on beef cattle grazed in Panicum maximum grasses in northwestern Argentina. Also, an analysis to discern how the R. microplus population was distributed amongst cattle was also performed to determine if partial selective treatment or cull the small proportion of more heavily infested animals are feasible options to control this tick. The strategic scheme of treatments was designed to act on the small 1st generation of R. microplus in early spring and prevent in that way the appearance of the annual peak of abundance of R. microplus in summer and autumn. Animals of the group 1 were treated with ivermectin 3.15% on day 0 (25th September 2015), with fluazuron on day 32 (27th October 2015) and with fipronil on day 75 (9th December 2015). Animals of group 2 formed the control group. The overall effect of the treatments was positively significant. The number of ticks observed on the control group was significantly higher than the number of ticks observed on the treated group in all post-treatment counts (P<0.01), with the only exception of the count of March. The distribution of parasites among cattle in all counts was adjusted to the negative binomial distribution, but a temporal variation in the tick aggregation levels associated to changes in tick abundance was found. The higher the abundance of R. microplus, the lower the aggregation. It was found that the steers (15.8% of the total number of animals evaluated) belonging to the high infestation group accounted for 23.0% of the total ticks. The strategic control method evaluated during this study provides a remarkable overall effect against R. microplus because it significantly reduces the tick infestation on cattle with only three applications of acaricides in one-year period. The analyses of tick distribution amongst cattle suggest that partial selective treatment and culling do not represent feasible methods to control R. microplus infestation on cattle. Copyright © 2017 Elsevier B.V. All rights reserved.
Applications of penetrating radiation for small animal imaging
NASA Astrophysics Data System (ADS)
Hasegawa, Bruce H.; Wu, Max C.; Iwata, Koji; Hwang, Andrew B.; Wong, Kenneth H.; Barber, William C.; Dae, Michael W.; Sakdinawat, Anne E.
2002-11-01
Researchers long have relied on research involving small animals to unravel scientific mysteries in the biological sciences, and to develop new diagnostic and therapeutic techniques in the medical and health sciences. Within the past 2 decades, new techniques have been developed to manipulate the genome of the mouse, allowing the development of transgenic and knockout models of mammalian and human disease, development, and physiology. Traditionally, much biological research involving small animals has relied on the use of invasive methods such as organ harvesting, tissue sampling, and autoradiography during which the animal was sacrificed to perform a single measurement. More recently, imaging techniques have been developed that assess anatomy and physiology in the intact animal, in a way that allows the investigator to follow the progression of disease, or to monitor the response to therapeutic interventions. Imaging techniques that use penetrating radiation at millimeter or submillimeter levels to image small animals include x-ray computed tomography (microCT), single-photon emission computed tomography (microSPECT), and imaging positron emission computed tomography (microPET). MicroCT generates cross-sectional slices which reveal the structure of the object with spatial resolution in the range of 50 to 100 microns. MicroSPECT and microPET are radionuclide imaging techniques in which a radiopharmaceutical is injected into the animal that is accumulated to metabolism, blood flow, bone remodeling, tumor growth, or other biological processes. Both microSPECT and microPET offer spatial resolutions in the range of 1-2 millimeters. However, microPET records annihilation photons produced by a positron-emitting radiopharmaceutical using electronic coincidence, and has a sensitivity approximately two orders of magnitude better than microSPECT, while microSPECT is compatible with gamma-ray emitting radiopharmaceuticals that are less expensive and more readily available than those used with microPET. High-resolution dual-modality imaging systems now are being developed that combine microPET or microSPECT with microCT in a way that facilitates more direct correlation of anatomy and physiology in the same animal. Small animal imaging allows researchers to perform experiments that are not possible with conventional invasive techniques, and thereby are becoming increasingly important tools for discovery of fundamental biological information, and development of new diagnostic and therapeutic techniques in the biomedical sciences.
A simple, rapid, and sensitive system for the evaluation of anti-viral drugs in rats
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Xiaoguang; Department of Medical Microbiology, Harbin Medical University, Harbin 150086; Center for AIDS Research, Kumamoto University, 2-2-1 Honjo, Kumamoto 860-0811
Highlights: Black-Right-Pointing-Pointer We established a novel, simple and rapid in vivo system for evaluation of anti-HIV-1 drugs with rats. Black-Right-Pointing-Pointer The system may be applicable for other antiviral drugs, and/or useful for initial screening in vivo. Black-Right-Pointing-Pointer In this system, TRI-1144 displayed the most potent anti-HIV-1 activity in vivo. -- Abstract: The lack of small animal models for the evaluation of anti-human immunodeficiency virus type 1 (HIV-1) agents hampers drug development. Here, we describe the establishment of a simple and rapid evaluation system in a rat model without animal infection facilities. After intraperitoneal administration of test drugs to rats, antiviralmore » activity in the sera was examined by the MAGI assay. Recently developed inhibitors for HIV-1 entry, two CXCR4 antagonists, TF14016 and FC131, and four fusion inhibitors, T-20, T-20EK, SC29EK, and TRI-1144, were evaluated using HIV-1{sub IIIB} and HIV-1{sub BaL} as representative CXCR4- and CCR5-tropic HIV-1 strains, respectively. CXCR4 antagonists were shown to only possess anti-HIV-1{sub IIIB} activity, whereas fusion inhibitors showed both anti-HIV-1{sub IIIB} and anti-HIV-1{sub BaL} activities in rat sera. These results indicate that test drugs were successfully processed into the rat sera and could be detected by the MAGI assay. In this system, TRI-1144 showed the most potent and sustained antiviral activity. Sera from animals not administered drugs showed substantial anti-HIV-1 activity, indicating that relatively high dose or activity of the test drugs might be needed. In conclusion, the novel rat system established here, 'phenotypic drug evaluation', may be applicable for the evaluation of various antiviral drugs in vivo.« less
Barro, Ana M Bada; Rivero, Arianna Iglesias; Goñi, Avelina León; Navarro, Bárbara O González; Angarica, Meilis Mesa; Ramírez, Belinda Sánchez; Bedoya, Darel Martínez; Triana, Consuelo González; Rodríguez, Axel Mancebo; Parada, Ángel Casacó
2012-12-17
Human epidermal growth factor receptor (HER1) constitutes a tumor associated antigen. Its overexpression in many epithelial tumors has been associated with bad prognosis and poor survival. Cancer vaccine based on the extracellular domain (ECD) of HER1 and adjuvated in very small sized proteoliposomes (VSSP) and Montanide ISA 51-VG is a new and complementary approach for the treatment of epithelial tumors. The present study deals with the immunogenicity of this vaccine in Macaca fascicularis monkeys and evaluation of its toxicity during 12 months. Twelve monkeys were randomized into two groups of 3 animals per sex: control and vaccinated. Treated monkeys received 9 doses of vaccination and were daily inspected for clinical signs. Body weight, rectal temperature, cardiac and respiratory rates were measured during the study. Humoral immune response, clinical pathology parameters and delayed type hypensensitivity were analyzed. Skin biopsy was performed at the end of the study in all animals. Animal's survival in the study was 100% (n=12). Local reactions were observed at the administration site of four treated animals (n=6), with two showing slight inflammatory cutaneous damage. Clinical pathology parameters were not affected. HER1 vaccine induced high IgG antibodies titers in the treated animals even when DTH was not observed. The induced antibodies recognized HER1+ tumor cell lines, decreased HER1 phosphorylation and showed anti-proliferative and pro-apoptotic effects in H125 cells. In general the present study showed that HER1 vaccine induced specific immune response in M. fascicularis monkeys and was well tolerated, suggesting it could be safely used in clinical studies in epithelial cancer patients. Copyright © 2012 Elsevier Ltd. All rights reserved.
Evaluation of attenuation and scatter correction requirements in small animal PET and SPECT imaging
NASA Astrophysics Data System (ADS)
Konik, Arda Bekir
Positron emission tomography (PET) and single photon emission tomography (SPECT) are two nuclear emission-imaging modalities that rely on the detection of high-energy photons emitted from radiotracers administered to the subject. The majority of these photons are attenuated (absorbed or scattered) in the body, resulting in count losses or deviations from true detection, which in turn degrades the accuracy of images. In clinical emission tomography, sophisticated correction methods are often required employing additional x-ray CT or radionuclide transmission scans. Having proven their potential in both clinical and research areas, both PET and SPECT are being adapted for small animal imaging. However, despite the growing interest in small animal emission tomography, little scientific information exists about the accuracy of these correction methods on smaller size objects, and what level of correction is required. The purpose of this work is to determine the role of attenuation and scatter corrections as a function of object size through simulations. The simulations were performed using Interactive Data Language (IDL) and a Monte Carlo based package, Geant4 application for emission tomography (GATE). In IDL simulations, PET and SPECT data acquisition were modeled in the presence of attenuation. A mathematical emission and attenuation phantom approximating a thorax slice and slices from real PET/CT data were scaled to 5 different sizes (i.e., human, dog, rabbit, rat and mouse). The simulated emission data collected from these objects were reconstructed. The reconstructed images, with and without attenuation correction, were compared to the ideal (i.e., non-attenuated) reconstruction. Next, using GATE, scatter fraction values (the ratio of the scatter counts to the total counts) of PET and SPECT scanners were measured for various sizes of NEMA (cylindrical phantoms representing small animals and human), MOBY (realistic mouse/rat model) and XCAT (realistic human model) digital phantoms. In addition, PET projection files for different sizes of MOBY phantoms were reconstructed in 6 different conditions including attenuation and scatter corrections. Selected regions were analyzed for these different reconstruction conditions and object sizes. Finally, real mouse data from the real version of the same small animal PET scanner we modeled in our simulations were analyzed for similar reconstruction conditions. Both our IDL and GATE simulations showed that, for small animal PET and SPECT, even the smallest size objects (˜2 cm diameter) showed ˜15% error when both attenuation and scatter were not corrected. However, a simple attenuation correction using a uniform attenuation map and object boundary obtained from emission data significantly reduces this error in non-lung regions (˜1% for smallest size and ˜6% for largest size). In lungs, emissions values were overestimated when only attenuation correction was performed. In addition, we did not observe any significant improvement between the uses of uniform or actual attenuation map (e.g., only ˜0.5% for largest size in PET studies). The scatter correction was not significant for smaller size objects, but became increasingly important for larger sizes objects. These results suggest that for all mouse sizes and most rat sizes, uniform attenuation correction can be performed using emission data only. For smaller sizes up to ˜ 4 cm, scatter correction is not required even in lung regions. For larger sizes if accurate quantization needed, additional transmission scan may be required to estimate an accurate attenuation map for both attenuation and scatter corrections.
Considerations for the nonclinical safety evaluation of antibody drug conjugates for oncology.
Roberts, Stanley A; Andrews, Paul A; Blanset, Diann; Flagella, Kelly M; Gorovits, Boris; Lynch, Carmel M; Martin, Pauline L; Kramer-Stickland, Kimberly; Thibault, Stephane; Warner, Garvin
2013-12-01
Antibody drug conjugates (ADCs) include monoclonal antibodies that are linked to cytotoxic small molecules. A number of these agents are currently being developed as anti-cancer agents designed to improve the therapeutic index of the cytotoxin (i.e., cytotoxic small molecule or cytotoxic agent) by specifically delivering it to tumor cells. This paper presents primary considerations for the nonclinical safety evaluation of ADCs and includes strategies for the evaluation of the entire ADC or the various individual components (i.e., antibody, linker or the cytotoxin). Considerations are presented on how to design a nonclinical safety assessment program to identify the on- and off-target toxicities to enable first-in-human (FIH) studies. Specific discussions are also included that provide details as to the need and how to conduct the studies for evaluating ADCs in genetic toxicology, tissue cross-reactivity, safety pharmacology, carcinogenicity, developmental and reproductive toxicology, biotransformation, toxicokinetic monitoring, bioanalytical assays, immunogenicity testing, test article stability and the selection of the FIH dose. Given the complexity of these molecules and our evolving understanding of their properties, there is no single all-encompassing nonclinical strategy. Instead, each ADC should be evaluated on a case-by-case scientifically-based approach that is consistent with ICH and animal research guidelines. Copyright © 2013 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hiecklen, J.; Meagher, J.F.; Weaver, J.
1981-12-01
Long--Evans hooded rats were exposed by inhalation to 9-27 ppm diethylhydroxylamine and the vapor of diethylamine hydrogen sulfite. In one of three test chambers each containing 45-49 rats, the rats were also exposed to 9 +/- 2 ppm of nitroethane. In the first 12 months of the experiment two males and two females from both the control chamber and the chamber containing all three gases were sacrificed at 3-month intervals. After the first year only moribund animals were sacrificed except at the very end of the study when all remaining animals were sacrificed. Although hematological and blood chemistry evaluations indicatedmore » no significant differences between the control and exposed animals, gross and microscopic pathologic findings showed some variations, especially in the first year. Very early one test animal developed a hemangioendothelioma, but no additional ones developed later. Also hydrometra of the uterus, a condition common in old virgin female rats, was found in four exposed and one control female. Chronic tracheitis was found in five exposed and two control animals. Thyroid lesions were seen in the exposed animals after 6 months exposure, but not in animals exposed 9 months or longer. Examinations for animals exposed more than 1 year indicated no significant differences between the control and test groups, except for interstitial cell tumors of the testes which showed up in 4 of the 47 exposed males that were examined compared to 0 in the 25 control males. However, this incidence (8.5%) is too small to establish any definite conclusion.« less
Marino, Anna Maria Fausta; Percipalle, Maurizio; Giunta, Renato Paolo; Salvaggio, Antonio; Caracappa, Giulia; Alfonzetti, Tiziana; Aparo, Alessandra; Reale, Stefano
2017-03-01
We report a rapid and reliable method for the detection of Toxoplasma gondii in meat and animal tissues based on real-time polymerase chain reaction (PCR). Samples were collected from cattle, small ruminants, horses, and pigs raised or imported into Sicily, Italy. All DNA preparations were assayed by real-time PCR tests targeted to a 98-bp long fragment in the AF 529-bp repeat element and to the B1 gene using specific primers. Diagnostic sensitivity (100%), diagnostic specificity (100%), limit of detection (0.01 pg), efficiency (92-109%), and precision (mean coefficient of variation = 0.60%), repeatability (100%), reproducibility (100%), and robustness were evaluated using 240 DNA extracted samples (120 positives and 120 negative as per the OIE nested PCR method) from different matrices. Positive results were confirmed by the repetition of both real-time and nested PCR assays. Our study demonstrates the viability of a reliable, rapid, and specific real-time PCR on a large scale to monitor contamination with Toxoplasma cysts in meat and animal specimens. This validated method can be used for postmortem detection in domestic and wild animals and for food safety purposes.
Caron, Alexis; Lelong, Christine; Pascual, Marie-Hélène; Benning, Véronique
2015-03-01
Minimizing the number of animals in regulatory toxicity studies while achieving study objectives to support the development of future medicines contributes to good scientific and ethical practices. Recent advances in technology have enabled the development of miniaturized blood sampling methods (including microsampling and dried blood spots) applicable to toxicokinetic determinations of small-molecule drugs. Implementation of miniaturized blood sampling methods in the context of biotherapeutic drugs is desirable because a limitation to this type of medicine remains the total blood volume needed from a single animal to support toxicokinetic determinations of several analytes (parent drug, metabolites[s], antidrug antibodies, and so forth). We describe here the technical details, applicability, and relevance of new miniaturized blood sampling procedures in mice and nonhuman primates in the context of the toxicologic evaluation of biotherapeutic drugs consisting of antibody-drug conjugates developed for oncology indications. These examples illustrate how these techniques can benefit the reduction of animal usage in mouse toxicity studies by decreasing the number of animals dedicated to toxicokinetic determinations and the refinement of practices in nonhuman primate toxicity studies by decreasing the blood volume repeatedly drawn for toxicokinetic determinations.
Caron, Alexis; Lelong, Christine; Pascual, Marie-Hélène; Benning, Véronique
2015-01-01
Minimizing the number of animals in regulatory toxicity studies while achieving study objectives to support the development of future medicines contributes to good scientific and ethical practices. Recent advances in technology have enabled the development of miniaturized blood sampling methods (including microsampling and dried blood spots) applicable to toxicokinetic determinations of small-molecule drugs. Implementation of miniaturized blood sampling methods in the context of biotherapeutic drugs is desirable because a limitation to this type of medicine remains the total blood volume needed from a single animal to support toxicokinetic determinations of several analytes (parent drug, metabolites[s], antidrug antibodies, and so forth). We describe here the technical details, applicability, and relevance of new miniaturized blood sampling procedures in mice and nonhuman primates in the context of the toxicologic evaluation of biotherapeutic drugs consisting of antibody–drug conjugates developed for oncology indications. These examples illustrate how these techniques can benefit the reduction of animal usage in mouse toxicity studies by decreasing the number of animals dedicated to toxicokinetic determinations and the refinement of practices in nonhuman primate toxicity studies by decreasing the blood volume repeatedly drawn for toxicokinetic determinations. PMID:25836960
Guiden, Peter W; Orrock, John L
2017-02-01
Recent evidence suggests that invasive exotic plants can provide novel habitats that alter animal behavior. However, it remains unclear whether classic animal-habitat associations that influence the spatial distribution of plant-animal interactions, such as small mammal use of downed woody debris, persist in invaded habitats. We removed an invasive exotic shrub (buckthorn, Rhamnus cathartica) from 7 of 15 plots in Wisconsin. In each plot, we deployed 200 tagged Quercus rubra seeds in November 2014. After five months, tags were recovered to track spatial patterns of small mammal seed predation. Most recovered tags were associated with consumed seeds (95%); live-trapping, ancillary camera-trapping, and previous behavioral studies suggest that white-footed mice (Peromyscus leucopus) were responsible for most seed predation. In habitats without R. cathartica, most seed predation occurred near woody debris. In habitats with R. cathartica, small mammals rarely consumed seeds near woody debris, and seed predation occurred farther from the plot center and was less spatially clustered. Our results illustrate that invasive exotic shrubs can disrupt an otherwise common animal-habitat relationship. Failing to account for changes in habitat use may diminish our ability to predict animal distributions and outcomes of species interactions in novel habitats created by invasive exotic plants. © 2016 by the Ecological Society of America.
Predicted trends in the supply and demand of veterinarians in Japan.
Kimura, S; Shinkawa, S; Mago, J; Yamamoto, M; Sakai, M; Sugisaki, T; Karaki, H; Sugiura, K
2008-12-01
Currently in Japan, there are 32,000 active veterinarians, mainly engaged in small and large animal practice and public animal health and public health services. In the face of the notable increase in recent years in the proportion of female students enrolled in veterinary schools and in the number of households with companion animals, a model was developed to predict the supply and demand of veterinarians toward 2040 in Japan. Surveys were conducted on sampled households and veterinarians to estimate input variables used in the supply and demand model. From this data it is predicted that there might be somewhere between a shortage of 1,000 to an over-supply of 3,700 veterinarians engaged in small animal practice in 2040. This, however, will depend on possible changes in the number of visits made to veterinarians by small animal owners and the efficiency of practices in the future. The model also predicts that there will be a shortage of around 1,100 veterinarians in large animal practice in 2040. Considering the many assumptions made to estimate the input variables used in the model, the results of this study do not provide definitive conclusions, but provide a base for discussions on what will be needed in the veterinary profession in the future.
Barnes, T S; Goldizen, A W; Morton, J M; Coleman, G T
2008-05-01
Infection of small macropodids with the larval stage of Echinococcus granulosus can cause fatalities as well as significant pulmonary impairment and other adverse sequelae. The brush-tailed rock-wallaby (Petrogale penicillata) is a small macropodid listed as vulnerable on the IUCN's Red List of Threatened Species. This study used radiographic techniques to determine the prevalence and severity of pulmonary hydatid infection and growth rates of hydatid cysts in a wild population of this macropodid. The overall prevalence was 15.3% (9/59 animals) with 20.0% (8/40 animals) of adults infected. During the study period, the death of at least 1 infected animal was directly attributed to pulmonary hydatidosis. Rapid cyst growth occurred in some animals (up to 43% increase in cyst volume in 3 months). Cyst volume reduced lung capacity by up to 17%. Secondary pulmonary changes were uncommon but, in 1 animal, resulted in reduction in lung capacity by approximately 50%. Infection was associated with a higher blood urea concentration, but no significant differences in other blood variables were detected. These results indicate that hydatid infection may be a significant risk to threatened populations of small macropodids and should be addressed in conservation management plans for these animals.
[The detection of the influenza virus in the small intestine in diarrhea in piglets].
Slobodeniuk, V K; Mel'nikova, L A; Kvashnina, G A; Semenchenko, O G; Trofimova, M G; Tatarchuk, A T; Raĭkova, N L
1990-01-01
Electron microscopy used for examinations of small intestine suspensions of piglets in the prenatal and postnatal periods allowed influenza virions to be identified in virus population. An attempt was made to preserve the discovered population in alternating animal--cell culture--animal passages. Serological examinations of the swine herd confirmed the circulation of influenza viruses in the herd.
Franzius, Christiane; Hotfilder, Marc; Poremba, Christopher; Hermann, Sven; Schäfers, Klaus; Gabbert, Helmut Erich; Jürgens, Heribert; Schober, Otmar; Schäfers, Michael; Vormoor, Josef
2006-12-01
As primary osseous metastasis is the main adverse prognostic factor in patients with Ewing tumours, a NOD/scid mouse model for human Ewing tumour metastases has been established to examine the mechanisms of metastasis. The aim of this study was to evaluate the feasibility of diagnostic molecular imaging by small animal PET in this mouse model. Human Ewing tumour cells were transplanted into immune-deficient NOD/scid mice via s.c injection (n=17) or i.v. injection (n=17). The animals (mean weight 23.2 g) were studied 2-7 weeks after transplantation using a submillimetre resolution animal PET scanner. To assess glucose utilisation and bone metabolism, mice were scanned after intravenous injection of 9.6 MBq (mean) 2-[(18)F]fluoro-2-deoxy-D: -glucose (FDG) or 9.4 MBq (mean) [(18)F]fluoride. Whole-body PET images were analysed visually and semi-quantitatively [%ID/g, tumour to non-tumour ratio (T/NT)]. Foci of pathological uptake were identified with respect to the physiological organ uptake in corresponding regions. Subcutaneously transplanted Ewing tumours demonstrated a moderately increased glucose uptake (median %ID/g 2.5; median T/NT 2.2). After i.v. transplantation, the pattern of metastasis was similar to that in patients with metastases in lung, bone and soft tissue. These metastases showed an increased FDG uptake (median %ID/g 3.6; median T/NT 2.7). Osseous metastases were additionally visible on [(18)F]fluoride PET by virtue of decreased [(18)F]fluoride uptake (osteolysis; median %ID/g 8.4; median T/NT 0.59). Metastases were confirmed immunohistologically. Diagnostic molecular imaging of Ewing tumours and their small metastases in an in vivo NOD/scid mouse model is feasible using a submillimetre resolution PET scanner.
Clinical biochemistry in healthy manatees (Trichechus manatus latirostris).
Harvey, John W; Harr, Kendal E; Murphy, David; Walsh, Michael T; Chittick, Elizabeth J; Bonde, Robert K; Pate, Melanie G; Deutsch, Charles J; Edwards, Holly H; Haubold, Elsa M
2007-06-01
Florida manatees (Trichechus manatus latirostris) are endangered aquatic mammals living in coastal and riverine waterways of Florida and adjacent states. Serum or plasma biochemical analyses are important tools in evaluating the health of free-ranging and captive manatees. The purpose of this study was to measure diagnostically important analytes in the plasma of healthy manatees and to determine whether there was significant variation with respect to location (free-ranging versus captive), age class (small calves, large calves, subadults, adults), and gender. No significant differences in plasma sodium, potassium, bilirubin, glucose, alanine aminotransferase, or creatine kinase were found among these classes of animals. Compared to free-ranging manatees, captive animals had significantly lower mean concentrations of plasma chloride, phosphate, magnesium, triglycerides, anion gap, and lactate. Captive manatees had significantly higher mean values of total CO2, calcium, urea, creatinine, alkaline phosphatase, gamma-glutamyltransferase, total protein, albumin, and albumin/globulin ratio than did free-ranging animals. Differences in the environments of these two groups, including diet, temperature, salinity, and stress, might account for some of these results. The higher plasma lactate and anion gap concentrations and lower total CO2 concentrations of free-ranging manatees were probably due to greater exertion during capture, but the lack of elevated plasma creatine kinase activity relative to captive animals indicates that there was no serious muscle injury associated with capture. Plasma phosphate decreased and total globulins increased with age. Plasma cholesterol and triglyceride concentrations were highest in small calves. Plasma aspartate aminotransferase was higher in large calves than in adults and subadults, and the albumin/ globulin ratio was higher in subadults than in adults. Plasma total CO2 was higher and chloride was slightly lower in females than in males.
Clinical biochemistry in healthy manatees (Trichechus manatus latirostris)
Harvey, J.W.; Harr, K.E.; Murphy, D.; Walsh, M.T.; Chittick, E.J.; Bonde, R.K.; Pate, M.G.; Deutsch, C.J.; Edwards, H.H.; Haubold, E.M.
2007-01-01
Florida manatees (Trichechus manatus latirostris) are endangered aquatic mammals living in coastal and riverine waterways of Florida and adjacent states. Serum or plasma biochemical analyses are important tools in evaluating the health of free-ranging and captive manatees. The purpose of this study was to measure diagnostically important analytes in the plasma of healthy manatees and to determine whether there was significant variation with respect to location (free-ranging versus captive), age class (small calves, large calves, subadults, adults), and gender. No significant differences in plasma sodium, potassium, bilirubin, glucose, alanine aminotransferase, or creatine kinase were found among these classes of animals. Compared to free-ranging manatees, captive animals had significantly lower mean concentrations of plasma chloride, phosphate, magnesium, triglycerides, anion gap, and lactate. Captive manatees had significantly higher mean values of total CO2, calcium, urea, creatinine, alkaline phosphatase, gamma-glutamyltransferase, total protein, albumin, and albumin/globulin ratio than did free-ranging animals. Differences in the environments of these two groups, including diet, temperature, salinity, and stress, might account for some of these results. The higher plasma lactate and anion gap concentrations and lower total CO2 concentrations of free-ranging manatees were probably due to greater exertion during capture, but the lack of elevated plasma creatine kinase activity relative to captive animals indicates that there was no serious muscle injury associated with capture. Plasma phosphate decreased and total globulins increased with age. Plasma cholesterol and triglyceride concentrations were highest in small calves. Plasma aspartate aminotransferase was higher in large calves than in adults and subadults, and the albumin/ globulin ratio was higher in subadults than in adults. Plasma total CO2 was higher and chloride was slightly lower in females than in males.
Uncovering Spatial Variation in Acoustic Environments Using Sound Mapping.
Job, Jacob R; Myers, Kyle; Naghshineh, Koorosh; Gill, Sharon A
2016-01-01
Animals select and use habitats based on environmental features relevant to their ecology and behavior. For animals that use acoustic communication, the sound environment itself may be a critical feature, yet acoustic characteristics are not commonly measured when describing habitats and as a result, how habitats vary acoustically over space and time is poorly known. Such considerations are timely, given worldwide increases in anthropogenic noise combined with rapidly accumulating evidence that noise hampers the ability of animals to detect and interpret natural sounds. Here, we used microphone arrays to record the sound environment in three terrestrial habitats (forest, prairie, and urban) under ambient conditions and during experimental noise introductions. We mapped sound pressure levels (SPLs) over spatial scales relevant to diverse taxa to explore spatial variation in acoustic habitats and to evaluate the number of microphones needed within arrays to capture this variation under both ambient and noisy conditions. Even at small spatial scales and over relatively short time spans, SPLs varied considerably, especially in forest and urban habitats, suggesting that quantifying and mapping acoustic features could improve habitat descriptions. Subset maps based on input from 4, 8, 12 and 16 microphones differed slightly (< 2 dBA/pixel) from those based on full arrays of 24 microphones under ambient conditions across habitats. Map differences were more pronounced with noise introductions, particularly in forests; maps made from only 4-microphones differed more (> 4 dBA/pixel) from full maps than the remaining subset maps, but maps with input from eight microphones resulted in smaller differences. Thus, acoustic environments varied over small spatial scales and variation could be mapped with input from 4-8 microphones. Mapping sound in different environments will improve understanding of acoustic environments and allow us to explore the influence of spatial variation in sound on animal ecology and behavior.
Design of a multimodal fibers optic system for small animal optical imaging.
Spinelli, Antonello E; Pagliazzi, Marco; Boschi, Federico
2015-02-01
Small animals optical imaging systems are widely used in pre-clinical research to image in vivo the bio-distribution of light emitting probes using fluorescence or bioluminescence modalities. In this work we presented a set of simulated results of a novel small animal optical imaging module based on a fibers optics matrix, coupled with a position sensitive detector, devoted to acquire bioluminescence and Cerenkov images. Simulations were performed using GEANT 4 code with the GAMOS architecture using the tissue optics plugin. Results showed that it is possible to image a 30 × 30 mm region of interest using a fiber optics array containing 100 optical fibers without compromising the quality of the reconstruction. The number of fibers necessary to cover an adequate portion of a small animal is thus quite modest. This design allows integrating the module with magnetic resonance (MR) in order to acquire optical and MR images at the same time. A detailed model of the mouse anatomy, obtained by segmentation of 3D MRI images, will improve the quality of optical 3D reconstruction. Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Canale, Angelo; Cosci, Francesca; Canovai, Roberto; Giannotti, Paolo; Benelli, Giovanni
2014-01-01
Propolis is a resinous material collected by honeybees from the exudates and buds of plants. It has been widely used as a remedy by humans since ancient times, as well as for dietary supplements and cosmetics. European legislation recently focused on the quality and hygiene standards of foods, including beehive products, and extensive efforts have been made to avoid the presence of chemical contaminants, whilst in contrast few studies have investigated the magnitude of contamination by physical ones. We conducted a filth-test survey to evaluate the contamination of ethanolic extract of propolis by foreign materials. We also compared the abundance of contaminants in propolis extracts currently marketed by small beekeepers and industrial producers. We found different foreign materials in the ethanol extract of propolis. Contaminants differed in abundance, with a higher number of carbon particles (small beekeepers: 2.70 ± 0.63; industrial producers: 1.25 ± 0.49; mean (n/30 ml) ± SE) and other inorganic fragments (small beekeepers: 3.50 ± 0.31; industrial producers: 3.88 ± 1.11) than arthropod fragments (small beekeepers: 0.30 ± 0.21; industrial producers: 0.38 ± 0.26) and mammal hairs (small beekeepers: 0.10 ± 0.10; industrial producers: 0.38 ± 0.26). No differences in the abundance of foreign matter between propolis from small beekeepers and industrial producers were found, allowing us to point out an increased awareness by small producers of issues inherent in hygiene management. Contamination of propolis extracts by animal body parts, such as insect fragments, mites and rodent hairs, indicates poor management of hygiene in the production process and low effectiveness of the filtration phase. Animal-borne contaminants can act as pathogen vectors as well as introducing dangerous allergens when ingested or applied to human skin. The filth-test applied to ethanolic propolis extract quality control can be considered a promising tool, also for small beekeeper activities, since it is cheap and allows the quick interpretation of results.
Lavari, L; Burns, P; Páez, R; Reinheimer, J; Vinderola, G
2017-10-01
To evaluate the effects of spray drying of Lactobacillus rhamnosus 64 on its capacity to modulate the gut immune response and on the attenuation of TNBS-induced colitis in mice. Lactobacillus rhamnosus 64 was spray dried in cheese whey-starch solution and administered to mice for 3, 6 or 10 consecutive days. Peritoneal macrophage phagocytic activity, secretory IgA levels in the small intestinal fluid and TNFα, IFNγ, IL-10, IL-6 and IL-2 levels in homogenates of the small and large intestine were determined. The effects of spray drying were also evaluated in an acute model of Trinitrobenzenesulfonic acid (TNBS)-induced colitis. A shift in the regulation of immune parameters, particularly the cytokine profile, was observed for mice treated with the spray-dried culture, compared to the profile observed in animals that received the strain as fresh culture (FC). The spray-dried culture of L. rhamnosus 64 showed anti-inflammatory properties in murine model of TNBS-induced colitis. The spray-drying process of L. rhamnosus 64 in whey-starch modified its immunomodulating capacity in healthy animals and conferred enhanced protection in an in vivo model of inflammation. Probiotic capacity can be affected by spray drying in relation to the properties observed for the strain as an overnight FC. This fact should be taken into account when producing the culture for its application in the industry. © 2017 The Society for Applied Microbiology.
Simultaneous PET and Multispectral 3-Dimensional Fluorescence Optical Tomography Imaging System
Li, Changqing; Yang, Yongfeng; Mitchell, Gregory S.; Cherry, Simon R.
2015-01-01
Integrated PET and 3-dimensional (3D) fluorescence optical tomography (FOT) imaging has unique and attractive features for in vivo molecular imaging applications. We have designed, built, and evaluated a simultaneous PET and 3D FOT system. The design of the FOT system is compatible with many existing small-animal PET scanners. Methods The 3D FOT system comprises a novel conical mirror that is used to view the whole-body surface of a mouse with an electron-multiplying charge-coupled device camera when a collimated laser beam is projected on the mouse to stimulate fluorescence. The diffusion equation was used to model the propagation of optical photons inside the mouse body, and 3D fluorescence images were reconstructed iteratively from the fluorescence intensity measurements measured from the surface of the mouse. Insertion of the conical mirror into the gantry of a small-animal PET scanner allowed simultaneous PET and 3D FOT imaging. Results The mutual interactions between PET and 3D FOT were evaluated experimentally. PET has negligible effects on 3D FOT performance. The inserted conical mirror introduces a reduction in the sensitivity and noise-equivalent count rate of the PET system and increases the scatter fraction. PET–FOT phantom experiments were performed. An in vivo experiment using both PET and FOT was also performed. Conclusion Phantom and in vivo experiments demonstrate the feasibility of simultaneous PET and 3D FOT imaging. The first in vivo simultaneous PET–FOT results are reported. PMID:21810591
ULTRASONOGRAPHIC DETECTION OF INGESTED FISHING LINES IN LOGGERHEADS ( CARETTA CARETTA).
Franchini, Delia; Valastro, Carmela; Ciccarelli, Stefano; Caprio, Francesco; Lenoci, Diana; Di Bello, Antonio
2018-05-23
Loggerhead sea turtles ( Caretta caretta) are among the most frequent victims of bycatch in drifting longlines, and the ingestion of fish hooks and fishing lines is one of the most frequent causes of death of sea turtles. The aim of this study was to evaluate whether coelomic ultrasound (US) can be decisive, not only for diagnosis but also to optimize surgical planning based on preoperative evaluation of the bowel conditions and, in addition, to see if there are characteristic sonographic findings in sea turtles associated with the ingestion of fishing lines. Physical examination, hematology, blood chemistry, radiographs, and US examination were performed in 37 loggerhead sea turtles with suspected or known ingestion of fish hooks or monofilament fishing lines. During the ultrasonographic examinations, the loggerhead sea turtles were placed in dorsal recumbency and the prefemoral left and right acoustic windows were used. Nine wild loggerheads had sonographic findings of intestinal and coelomic abnormalities, and the sonographic images were compared with the surgical findings. Ultrasonography positively identified the foreign body in 89% (8/9) animals. The presence of intestinal plication (in all loggerhead turtles) and ultrasonographic visualization of the linear foreign body was always consistent with the ingestion of a fishing line. In sea turtles, fishing lines cause a corrugated appearance in the small intestine due to increased/unproductive peristalsis. The affected small bowel loops are usually dilated with fluid. In the present study, coelomic US allowed us to make a thorough evaluation of the characteristics, number, and severity of the bowel wall lesions in the animals, thus ensuring the planning of a correct surgical procedure. We suggest that US examination of the coelomic cavity should be complementary to radiographic survey in cases of suspected ingestion of fish hooks and fishing lines by sea turtles.
Green, Michael V; Seidel, Jurgen; Choyke, Peter L; Jagoda, Elaine M
2017-10-01
We describe a simple fixture that can be added to the imaging bed of a small-animal PET scanner that allows for automated counting of multiple organ or tissue samples from mouse-sized animals and counting of injection syringes prior to administration of the radiotracer. The combination of imaging and counting capabilities in the same machine offers advantages in certain experimental settings. A polyethylene block of plastic, sculpted to mate with the animal imaging bed of a small-animal PET scanner, is machined to receive twelve 5-ml containers, each capable of holding an entire organ from a mouse-sized animal. In addition, a triangular cross-section slot is machined down the centerline of the block to secure injection syringes from 1-ml to 3-ml in size. The sample holder is scanned in PET whole-body mode to image all samples or in one bed position to image a filled injection syringe. Total radioactivity in each sample or syringe is determined from the reconstructed images of these objects using volume re-projection of the coronal images and a single region-of-interest for each. We tested the accuracy of this method by comparing PET estimates of sample and syringe activity with well counter and dose calibrator estimates of these same activities. PET and well counting of the same samples gave near identical results (in MBq, R 2 =0.99, slope=0.99, intercept=0.00-MBq). PET syringe and dose calibrator measurements of syringe activity in MBq were also similar (R 2 =0.99, slope=0.99, intercept=- 0.22-MBq). A small-animal PET scanner can be easily converted into a multi-sample and syringe counting device by the addition of a sample block constructed for that purpose. This capability, combined with live animal imaging, can improve efficiency and flexibility in certain experimental settings. Copyright © 2017 Elsevier Inc. All rights reserved.
Prototype design of singles processing unit for the small animal PET
NASA Astrophysics Data System (ADS)
Deng, P.; Zhao, L.; Lu, J.; Li, B.; Dong, R.; Liu, S.; An, Q.
2018-05-01
Position Emission Tomography (PET) is an advanced clinical diagnostic imaging technique for nuclear medicine. Small animal PET is increasingly used for studying the animal model of disease, new drugs and new therapies. A prototype of Singles Processing Unit (SPU) for a small animal PET system was designed to obtain the time, energy, and position information. The energy and position is actually calculated through high precison charge measurement, which is based on amplification, shaping, A/D conversion and area calculation in digital signal processing domian. Analysis and simulations were also conducted to optimize the key parameters in system design. Initial tests indicate that the charge and time precision is better than 3‰ FWHM and 350 ps FWHM respectively, while the position resolution is better than 3.5‰ FWHM. Commination tests of the SPU prototype with the PET detector indicate that the system time precision is better than 2.5 ns, while the flood map and energy spectra concored well with the expected.
An environmental chamber system for prolonged metabolic studies on small animals
NASA Technical Reports Server (NTRS)
Jordan, J. P.; Huston, L. J.; Simmons, J. B., II; Clarkson, D. P.; Martz, W. W.; Schatte, C. L.
1973-01-01
Measurement of metabolic adaptation to marginally stressful environments requires both precise regulation of a variety of atmospheric factors for extended periods of time and the capacity to employ sensitive parameters in an undisturbed subject. This paper describes a metabolic chamber system which can simultaneously maintain groups of small animals in two completely separate closed environments having different pressures, temperatures and gas compositions for an indefinite period. Oxygen consumption, carbon dioxide production, food and water consumption and animal activity cycles can be continuously monitored and quantified 24 h per day while the animals are in an unrestrained state. Each chamber can be serviced and the animals handled, injected and sacrificed without subjecting them to barometric stress. Several unique electrical and mechanical components allow semi-automated data collection on a continuous basis for indefinite periods of time.
An Experimental Aneurysm Model: a Training Model for Neurointerventionalists
Grunwald, I.Q.; Romeike, B.; Eymann, R.; Roth, C.; Struffert, T.; Reith, W.
2006-01-01
Summary Reproducible animal models not only facilitate the pre-clinical assessment of aneurysm therapy but can also help in training for interventional procedures. The objective of this study was to find an animal model that can be used to test different endovascular occlusion techniques. Aneurysms in the right common carotid artery were created in 35 NZW rabbits by distal ligation and intraluminal elastase infusion. A total of 27 aneurysms were occluded by endovascular embolization with GDC-Coils. The time needed for placement of the microcatheter into the aneurysm by a professional interventionalist, a semi-professional interventionalist and a trainee was measured. The percentage of occlusion (occlusion rate) of the aneurysms was determined angiographically after embolization and again three months later, followed by a histological examination. Aneurysms of 2-6 mm size were reliably created in all 35 animals; mean size was 3.0 mm in height and 5.5 mm in diameter. Occlusion was achieved in 27 animals. Five animals from the group of 35 were initially planned as a control group with no embolization. We added to the control group one animal whose aneurysm could not be occluded endovascularly because of partial thrombosis and small size of the aneurysm. The angiographically determined mean occlusion rate was 89.5% ± 11.3% standard deviation. Histological evaluation of the six aneurysms of the control group showed that they remained patent. Aneurysms that underwent embolization showed organized thrombus formation with no signs of recanalization. Two animals died from anaesthesia related or embolic complications. The time needed by the professional did not significantly decrease, after a little practice the trainee was nearly as quick as the professional. The beginner showed extensive progress, reducing the time for catheter placement by more than 50%. This paper describes the angiographic and histopathologic findings and also demonstrates possible methods for training in interventional procedures. Animal models will play a vital part in the training of future interventionalists. This model has the capability of testing different embolization devices (GDC, Onyx®) and methods. Histologic long-term prognosis and the physical effect of the coils can be evaluated with this model. PMID:20569546
Houston, Derek D.; Azeem, Shahan; Lundy, Coady W.; Sato, Yuko; Guo, Baoqing; Blanchong, Julie A.; Gauger, Phillip C.; Marks, David R.
2017-01-01
Background Avian influenza virus (AIV) infections occur naturally in wild bird populations and can cross the wildlife-domestic animal interface, often with devastating impacts on commercial poultry. Migratory waterfowl and shorebirds are natural AIV reservoirs and can carry the virus along migratory pathways, often without exhibiting clinical signs. However, these species rarely inhabit poultry farms, so transmission into domestic birds likely occurs through other means. In many cases, human activities are thought to spread the virus into domestic populations. Consequently, biosecurity measures have been implemented to limit human-facilitated outbreaks. The 2015 avian influenza outbreak in the United States, which occurred among poultry operations with strict biosecurity controls, suggests that alternative routes of virus infiltration may exist, including bridge hosts: wild animals that transfer virus from areas of high waterfowl and shorebird densities. Methods Here, we examined small, wild birds (songbirds, woodpeckers, etc.) and mammals in Iowa, one of the regions hit hardest by the 2015 avian influenza epizootic, to determine whether these animals carry AIV. To assess whether influenza A virus was present in other species in Iowa during our sampling period, we also present results from surveillance of waterfowl by the Iowa Department of Natural Resources and Unites Stated Department of Agriculture. Results Capturing animals at wetlands and near poultry facilities, we swabbed 449 individuals, internally and externally, for the presence of influenza A virus and no samples tested positive by qPCR. Similarly, serology from 402 animals showed no antibodies against influenza A. Although several species were captured at both wetland and poultry sites, the overall community structure of wild species differed significantly between these types of sites. In contrast, 83 out of 527 sampled waterfowl tested positive for influenza A via qPCR. Discussion These results suggest that even though influenza A viruses were present on the Iowa landscape at the time of our sampling, small, wild birds and rodents were unlikely to be frequent bridge hosts. PMID:29255648
Activation of the cannabinoid system in the nucleus accumbens affects effort-based decision making.
Fatahi, Zahra; Haghparast, Abbas
2018-02-01
Effort-based decision making addresses how we make an action choice based on an integration of action and goal values. The nucleus accumbens (NAc) is implicated in allowing an animal to overcome effort constraints to obtain greater benefits, and it has been previously shown that cannabis derivatives may affect such processes. Therefore, in this study, we intend to evaluate the involvement of the cannabinoid system in the entire NAc on effort-based decision making. Rats were trained in a T-maze cost-benefit decision making the task in which they could choose either to climb a barrier to obtain a large reward in one arm or run into the other arm without a barrier to obtaining a small reward. Following training, the animals were bilaterally implanted with guide cannulae in the NAc. On test day, rats received cannabinoid agonist (Win 55,212-2; 2, 10 and 50μM) and/or antagonist (AM251; 45μM), afterward percentage of large reward choice and latency of reward attainment were investigated. Results revealed that the administration of cannabinoid agonist led to decrease of large reward choice percentage such that the animals preferred to receive a small reward with low effort instead of receiving a large reward with high effort. The administration of antagonist solely did not affect effort-based decision making, but did attenuate the Win 55,212-2-induced impairments in effort allocation. In agonist-treated animals, the latency of reward collection increased. Moreover, when the effort was equated on both arms, the animals returned to choosing large reward showing that obtained results were not caused by spatial memory impairment. Our finding suggested that activation of the cannabinoid system in the NAc impaired effort-based decision making and led to rats were less willing to invest the physical effort to gain large reward. Copyright © 2017 Elsevier Inc. All rights reserved.
FIMTrack: An open source tracking and locomotion analysis software for small animals.
Risse, Benjamin; Berh, Dimitri; Otto, Nils; Klämbt, Christian; Jiang, Xiaoyi
2017-05-01
Imaging and analyzing the locomotion behavior of small animals such as Drosophila larvae or C. elegans worms has become an integral subject of biological research. In the past we have introduced FIM, a novel imaging system feasible to extract high contrast images. This system in combination with the associated tracking software FIMTrack is already used by many groups all over the world. However, so far there has not been an in-depth discussion of the technical aspects. Here we elaborate on the implementation details of FIMTrack and give an in-depth explanation of the used algorithms. Among others, the software offers several tracking strategies to cover a wide range of different model organisms, locomotion types, and camera properties. Furthermore, the software facilitates stimuli-based analysis in combination with built-in manual tracking and correction functionalities. All features are integrated in an easy-to-use graphical user interface. To demonstrate the potential of FIMTrack we provide an evaluation of its accuracy using manually labeled data. The source code is available under the GNU GPLv3 at https://github.com/i-git/FIMTrack and pre-compiled binaries for Windows and Mac are available at http://fim.uni-muenster.de.
Magnetic hyperthermia with hard-magnetic nanoparticles
NASA Astrophysics Data System (ADS)
Kashevsky, Bronislav E.; Kashevsky, Sergey B.; Korenkov, Victor S.; Istomin, Yuri P.; Terpinskaya, Tatyana I.; Ulashchik, Vladimir S.
2015-04-01
Recent clinical trials of magnetic hyperthermia have proved, and even hardened, the Ankinson-Brezovich restriction as upon magnetic field conditions applicable to any site of human body. Subject to this restriction, which is harshly violated in numerous laboratory and small animal studies, magnetic hyperthermia can relay on rather moderate heat source, so that optimization of the whole hyperthermia system remains, after all, the basic problem predetermining its clinical perspectives. We present short account of our complex (theoretical, laboratory and small animal) studies to demonstrate that such perspectives should be related with the hyperthermia system based on hard-magnetic (Stoner-Wohlfarth type) nanoparticles and strong low-frequency fields rather than with superparamagnetic (Brownian or Neél) nanoparticles and weak high-frequency fields. This conclusion is backed by an analytical evaluation of the maximum absorption rates possible under the field restriction in the ideal hard-magnetic (Stoner-Wohlarth) and the ideal superparamagnetic (single relaxation time) systems, by theoretical and experimental studies of the dynamic magnetic hysteresis in suspensions of movable hard-magnetic particles, by producing nanoparticles with adjusted coercivity and suspensions of such particles capable of effective energy absorption and intratumoral penetration, and finally, by successful treatment of a mice model tumor under field conditions acceptable for whole human body.
Sinha, Sougata; Dey, Gourab; Kumar, Sunil; Mathew, Jomon; Mukherjee, Trinetra; Mukherjee, Subhrakanti; Ghosh, Subrata
2013-11-27
Structure-interaction/fluorescence relationship studies led to the development of a small chemical library of Zn(2+)-specific cysteamine-based molecular probes. The probe L5 with higher excitation/emission wavelengths, which absorbs in the visible region and emits in the green, was chosen as a model imaging material for biological studies. After successful imaging of intracellular zinc in four different kinds of cells including living organisms, plant, and animal cells, in vivo imaging potential of L5 was evaluated using plant systems. In vivo imaging of translocation of zinc through the stem of a small herb with a transparent stem, Peperomia pellucida, confirmed the stability of L5 inside biological systems and the suitability of L5 for real-time analysis. Similarly, fluorescence imaging of zinc in gram sprouts revealed the efficacy of the probe in the detection and localization of zinc in cereal crops. This imaging technique will help in knowing the efficiency of various techniques used for zinc enrichment of cereal crops. Computational analyses were carried out to better understand the structure, the formation of probe-Zn(2+) complexes, and the emission properties of these complexes.
Modality comparison for small animal radiotherapy: A simulation study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bazalova, Magdalena, E-mail: bazalova@stanford.edu; Nelson, Geoff; Noll, John M.
Purpose: Small animal radiation therapy has advanced significantly in recent years. Whereas in the past dose was delivered using a single beam and a lead shield for sparing of healthy tissue, conformal doses can be now delivered using more complex dedicated small animal radiotherapy systems with image guidance. The goal of this paper is to investigate dose distributions for three small animal radiation treatment modalities. Methods: This paper presents a comparison of dose distributions generated by the three approaches—a single-field irradiator with a 200 kV beam and no image guidance, a small animal image-guided conformal system based on a modified microCTmore » scanner with a 120 kV beam developed at Stanford University, and a dedicated conformal system, SARRP, using a 220 kV beam developed at Johns Hopkins University. The authors present a comparison of treatment plans for the three modalities using two cases: a mouse with a subcutaneous tumor and a mouse with a spontaneous lung tumor. A 5 Gy target dose was calculated using the EGSnrc Monte Carlo codes. Results: All treatment modalities generated similar dose distributions for the subcutaneous tumor case, with the highest mean dose to the ipsilateral lung and bones in the single-field plan (0.4 and 0.4 Gy) compared to the microCT (0.1 and 0.2 Gy) and SARRP (0.1 and 0.3 Gy) plans. The lung case demonstrated that due to the nine-beam arrangements in the conformal plans, the mean doses to the ipsilateral lung, spinal cord, and bones were significantly lower in the microCT plan (2.0, 0.4, and 1.9 Gy) and the SARRP plan (1.5, 0.5, and 1.8 Gy) than in single-field irradiator plan (4.5, 3.8, and 3.3 Gy). Similarly, the mean doses to the contralateral lung and the heart were lowest in the microCT plan (1.5 and 2.0 Gy), followed by the SARRP plan (1.7 and 2.2 Gy), and they were highest in the single-field plan (2.5 and 2.4 Gy). For both cases, dose uniformity was greatest in the single-field irradiator plan followed by the SARRP plan due to the sensitivity of the lower energy microCT beam to target heterogeneities and image noise. Conclusions: The two treatment planning examples demonstrate that modern small animal radiotherapy techniques employing image guidance, variable collimation, and multiple beam angles deliver superior dose distributions to small animal tumors as compared to conventional treatments using a single-field irradiator. For deep-seated mouse tumors, however, higher-energy conformal radiotherapy could result in higher doses to critical organs compared to lower-energy conformal radiotherapy. Treatment planning optimization for small animal radiotherapy should therefore be developed to take full advantage of the novel conformal systems.« less
The influence of intention and outcome on evaluations of social interaction.
Wu, Xiaoying; Hua, Rui; Yang, Zhangxiang; Yin, Jun
2018-01-01
Reading and making sense of social interactions between individuals is an important part of our daily social lives. Given that actions tend to be interpreted in terms of intent within the observed outcome, we investigated how intent and outcome interactively influence evaluations of social interactions. Through visual animations, intent was operationalized as an agent's (i.e., actor's) act intentionally or unintentionally having an influence on another agent (i.e., affectee). In Experiment 1, the act was helpful and the consequences brought small or great benefits to the affectee. In Experiment 2, the act was harmful and brought small or great losses to the affectee. We found that for both helpful and harmful contexts, social interaction evaluations were influenced by an interaction between the intent and outcome of the act. Specifically, great help/harm (i.e., the great-benefits or great-losses condition) was rated as a stronger social interaction than small help/harm, and the difference was larger in the intentional condition than in the unintentional condition. Furthermore, regardless of the interaction valence, the effect of the intent was larger than the effect of the outcome when evaluating social interaction. This result suggests that observers consider the intent and outcome jointly when evaluating a given social interaction, and the intent has a privileged role in this process. These findings are consistent with the idea that the intent is often deemed to be the cause driving the effect of outcome, and they help us to understand how social interactions are constructed within the action understanding system. Copyright © 2017 Elsevier B.V. All rights reserved.
Kozak, Robert; He, Shihua; Kroeker, Andrea; de La Vega, Marc-Antoine; Audet, Jonathan; Wong, Gary; Urfano, Chantel; Antonation, Kym; Embury-Hyatt, Carissa; Kobinger, Gary P; Qiu, Xiangguo
2016-10-15
Bundibugyo virus (BDBV) is the etiological agent of a severe hemorrhagic fever in humans with a case-fatality rate ranging from 25 to 36%. Despite having been known to the scientific and medical communities for almost 1 decade, there is a dearth of studies on this pathogen due to the lack of a small animal model. Domestic ferrets are commonly used to study other RNA viruses, including members of the order Mononegavirales To investigate whether ferrets were susceptible to filovirus infections, ferrets were challenged with a clinical isolate of BDBV. Animals became viremic within 4 days and succumbed to infection between 8 and 9 days, and a petechial rash was observed with moribund ferrets. Furthermore, several hallmarks of human filoviral disease were recapitulated in the ferret model, including substantial decreases in lymphocyte and platelet counts and dysregulation of key biochemical markers related to hepatic/renal function, as well as coagulation abnormalities. Virological, histopathological, and immunohistochemical analyses confirmed uncontrolled BDBV replication in the major organs. Ferrets were also infected with Ebola virus (EBOV) to confirm their susceptibility to another filovirus species and to potentially establish a virus transmission model. Similar to what was seen with BDBV, important hallmarks of human filoviral disease were observed in EBOV-infected ferrets. This study demonstrates the potential of this small animal model for studying BDBV and EBOV using wild-type isolates and will accelerate efforts to understand filovirus pathogenesis and transmission as well as the development of specific vaccines and antivirals. The 2013-2016 outbreak of Ebola virus in West Africa has highlighted the threat posed by filoviruses to global public health. Bundibugyo virus (BDBV) is a member of the genus Ebolavirus and has caused outbreaks in the past but is relatively understudied, likely due to the lack of a suitable small animal model. Such a model for BDBV is crucial to evaluating vaccines and therapies and potentially understanding transmission. To address this, we demonstrated that ferrets are susceptible models to BDBV infection as well as to Ebola virus infection and that no virus adaptation is required. Moreover, these animals develop a disease that is similar to that seen in humans and nonhuman primates. We believe that this will improve the ability to study BDBV and provide a platform to test vaccines and therapeutics. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Kozak, Robert; He, Shihua; Kroeker, Andrea; de La Vega, Marc-Antoine; Audet, Jonathan; Wong, Gary; Urfano, Chantel; Antonation, Kym; Embury-Hyatt, Carissa; Kobinger, Gary P.
2016-01-01
ABSTRACT Bundibugyo virus (BDBV) is the etiological agent of a severe hemorrhagic fever in humans with a case-fatality rate ranging from 25 to 36%. Despite having been known to the scientific and medical communities for almost 1 decade, there is a dearth of studies on this pathogen due to the lack of a small animal model. Domestic ferrets are commonly used to study other RNA viruses, including members of the order Mononegavirales. To investigate whether ferrets were susceptible to filovirus infections, ferrets were challenged with a clinical isolate of BDBV. Animals became viremic within 4 days and succumbed to infection between 8 and 9 days, and a petechial rash was observed with moribund ferrets. Furthermore, several hallmarks of human filoviral disease were recapitulated in the ferret model, including substantial decreases in lymphocyte and platelet counts and dysregulation of key biochemical markers related to hepatic/renal function, as well as coagulation abnormalities. Virological, histopathological, and immunohistochemical analyses confirmed uncontrolled BDBV replication in the major organs. Ferrets were also infected with Ebola virus (EBOV) to confirm their susceptibility to another filovirus species and to potentially establish a virus transmission model. Similar to what was seen with BDBV, important hallmarks of human filoviral disease were observed in EBOV-infected ferrets. This study demonstrates the potential of this small animal model for studying BDBV and EBOV using wild-type isolates and will accelerate efforts to understand filovirus pathogenesis and transmission as well as the development of specific vaccines and antivirals. IMPORTANCE The 2013-2016 outbreak of Ebola virus in West Africa has highlighted the threat posed by filoviruses to global public health. Bundibugyo virus (BDBV) is a member of the genus Ebolavirus and has caused outbreaks in the past but is relatively understudied, likely due to the lack of a suitable small animal model. Such a model for BDBV is crucial to evaluating vaccines and therapies and potentially understanding transmission. To address this, we demonstrated that ferrets are susceptible models to BDBV infection as well as to Ebola virus infection and that no virus adaptation is required. Moreover, these animals develop a disease that is similar to that seen in humans and nonhuman primates. We believe that this will improve the ability to study BDBV and provide a platform to test vaccines and therapeutics. PMID:27489269
Hussein, Mahmoud R; Abu-Dief, Eman E; Kamel, Esam; Abou El-Ghait, Amal T; Abdulwahed, Saad Rezk; Ahmad, Mohamed H
2008-11-01
Roentgen irradiation can affect normal cells, especially the rapidly growing ones such as the mucosal epithelial cells of the small intestine. The small intestine is the most radiosensitive gastrointestinal organ and patients receiving radiotherapy directed to the abdomen or pelvis may develop radiation enteritis. Although roentgen rays are widely used for both imaging and therapeutic purposes, our knowledge about the morphological changes associated with radiation enteritis is lacking. This study tries to tests the hypothesis that "the intake of melatonin can minimize the morphological features of cell damage associated with radiation enteritis". We performed this investigation to test our hypothesis and to examine the possible radioprotective effects of melatonin in acute radiation enteritis. To achieve these goals, an animal model consisting of 60 Albino rats was established. The animals were divided into five groups: Group 1, non-irradiated; Group 2, X-ray irradiated (X-ray irradiation, 8 Grays); Group 3, X-ray irradiated-pretreated with solvent (ethanol and phosphate buffered saline); Group 4, non-irradiated-group treated with melatonin, and Group 5, X-ray irradiated-pretreated with melatonin. The small intestines were evaluated for gross (macroscopic), histological, morphometric (light microscopy), and ultrastructural changes (transmission electron microscopy). We found morphological variations among the non-irradiated-group, X-ray irradiated-group and X-ray irradiated-intestines of the animals pretreated with melatonin. The development of acute radiation enteritis in X-ray irradiated-group (Groups 2 and 3) was associated with symptoms of enteritis (diarrhea and abdominal distention) and histological features of mucosal injury (mucosal ulceration, necrosis of the epithelial cells). There was a significant reduction of the morphometric parameters (villous count, villous height, crypt height and villous/crypt height ratio). Moreover, the ultrastructural features of cell damage were evident including: apoptosis, lack of parallel arrangement of the microvilli, loss of the covering glycocalyx, desquamation of the microvilli, vacuolation of the apical parts of the cells, dilatation of the rough endoplasmic reticulum, and damage of the mitochondrial cristae. In the non-irradiated-group and in X-ray irradiated-intestines of the animals pretreated with melatonin (Group 5), these changes were absent and the intestinal mucosal structure was preserved. Administration of melatonin prior to irradiation can protect the intestine against X-rays destructive effects, i.e. radiation enteritis. The clinical applications of these observations await further studies.
Paterson, R T; Joaquín, N; Chamón, K; Palomino, E
2001-02-01
The productivity of the scavenging, small animal species (chickens, ducks, pigs, hair sheep and guinea-pigs) commonly found on small-scale farms at the forest margin in subtropical Bolivia was monitored over a full year. Chickens and guinea-pigs were kept mainly for home consumption, while ducks and pigs were kept mainly for sale. Sheep served both purposes, depending upon the family requirements. In the absence of veterinary treatment, the productivity varied greatly between farms. Pigs gave the greatest gross return, but received the largest amount of supplementary feed. Under the existing system, chickens, ducks and sheep all gave similar gross returns per breeding female, although chickens produced good returns and made a large contribution to the family diet where the reproductive efficiency was high and the chick mortality was low. Mortality resulting from disease was a major problem in poultry, while internal parasites appeared to be important limiting factors in pigs and sheep. Guinea-pigs showed no major problems apart from theft, and were an important dietary component for immigrant families from the highlands of the country. Small animal species have largely been ignored by agricultural research and development activities in Bolivia and elsewhere. They currently make significant contributions to the livelihoods of poor people in terms of both income and food security, and this could be greatly increased by simple improvements in animal husbandry.
9 CFR 104.4 - Products for research and evaluation.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Products for research and evaluation. 104.4 Section 104.4 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT... BIOLOGICAL PRODUCTS § 104.4 Products for research and evaluation. (a) An application for a U.S. Veterinary...
9 CFR 112.9 - Biological products imported for research and evaluation.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 9 Animals and Animal Products 1 2012-01-01 2012-01-01 false Biological products imported for research and evaluation. 112.9 Section 112.9 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION... PACKAGING AND LABELING § 112.9 Biological products imported for research and evaluation. A biological...
9 CFR 112.9 - Biological products imported for research and evaluation.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 9 Animals and Animal Products 1 2013-01-01 2013-01-01 false Biological products imported for research and evaluation. 112.9 Section 112.9 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION... PACKAGING AND LABELING § 112.9 Biological products imported for research and evaluation. A biological...
9 CFR 112.9 - Biological products imported for research and evaluation.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 9 Animals and Animal Products 1 2011-01-01 2011-01-01 false Biological products imported for research and evaluation. 112.9 Section 112.9 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION... PACKAGING AND LABELING § 112.9 Biological products imported for research and evaluation. A biological...
9 CFR 112.9 - Biological products imported for research and evaluation.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 9 Animals and Animal Products 1 2014-01-01 2014-01-01 false Biological products imported for research and evaluation. 112.9 Section 112.9 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION... PACKAGING AND LABELING § 112.9 Biological products imported for research and evaluation. A biological...
9 CFR 112.9 - Biological products imported for research and evaluation.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Biological products imported for research and evaluation. 112.9 Section 112.9 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION... PACKAGING AND LABELING § 112.9 Biological products imported for research and evaluation. A biological...
Besson, Thomas; Debayle, Delphine; Diochot, Sylvie; Salinas, Miguel; Lingueglia, Eric
2016-08-01
Extracting venom from small species is usually challenging. We describe here an affordable and versatile electrical venom extractor based on the Arduino(®) Mega 2560 Board, which is designed to extract venom from arthropods and other small animals. The device includes fine tuning of stimulation time and voltage. It was used to collect venom without apparent deleterious effects, and characterized for the first time the venom of Zoropsis spinimana, a common spider in French Mediterranean regions. Copyright © 2016 Elsevier Ltd. All rights reserved.
Monagail, Michéal Mac; Cummins, Enda; Bermejo, Ricardo; Daly, Eve; Costello, Declan; Morrison, Liam
2018-06-20
Seaweed has a long-associated history of use as a supplemented livestock feed, providing nutrients and vitamins essential to maintaining animal health. Some species of seaweed, particularly the fucoids, are well-known accumulators of the metalloid arsenic (As). Arsenic toxicity to humans is well established even at low exposure levels and is considered a class 1 human carcinogen. As mankind's appetite for livestock produce continues to grow unabated, there is a concern that consumption of livestock produce reared on a diet supplemented with seaweed animal feed (SAF) may pose a threat to the human population due to potentially high levels of As present in seaweed. To address this concern and provide end users, including industry, consumers, policymakers and regulators with information on the exposure associated with As in commercial seaweed animal feed, the estimated daily intake (EDI) of As was calculated to evaluate potential human exposure levels. Using As data from a commercially available seaweed meal over a five-year period (2012-2017) a population exposure assessment was carried out. A Monte Carlo simulation model was developed to characterise the feed to food transfer of As from animal feed to animal produce such as beef, milk, chicken, and eggs. The model examined initial levels in seaweed, inclusion rate in animal feed, animal feeding rates and potential transfer to food produced from a supplemented diet of SAF. The analysis of seaweed animal feed showed that inorganic As was a small fraction of the total As found in seaweed meal (80:1). Statistical analysis found significant differences in the concentration of As in seaweed animal feed depending on the grain size (p < 0.001), with higher As concentrations in smaller sized grain fractions. Due to several detoxification steps and subsequent rapid excretion from the bodies of livestock, a very low carryover rate of As compounds from seaweed animal feed into livestock produce was observed. The EDI calculated in this study for the livestock produce evaluated at the 95th confidence interval was <0.01% of suggested safe levels of inorganic As intake. The threat to the general population as a result of consumption of livestock products reared on a diet consisting of SAF is found to be negligible. Copyright © 2018 Elsevier Ltd. All rights reserved.
Arthofer, Wolfgang; Decristoforo, Clemens; Schlick-Steiner, Birgit C.; Steiner, Florian M.
2016-01-01
Knowledge of a species’ ecology, including its movement in time and space, is key for many questions in biology and conservation. While numerous tools for tracking larger animals are available, millimetre-sized insects are averse to standard tracking and labelling procedures. Here, we evaluated the applicability of ultra-low, permission-exempt activities of the metastable isomer of the radionuclide Technetium-99 for labelling and field detection of the mountain fly Drosophila nigrosparsa. We demonstrate that an activity of less than 10 MBq is sufficient to label dozens of flies and detect single individuals using standard radiation protection monitors. The methodology presented here is applicable to many small-sized, low-mobility animals as well as independent from light and weather conditions and visual contact with the target organism. PMID:27812000
Design and adaptation of a folded split ring resonator antenna for use in an animal-borne sensor
NASA Astrophysics Data System (ADS)
Dodson, S. C.; Wiid, P. G.; Niesler, T. R.
2018-03-01
We present the design, optimisation and practical evaluation of a folded split ring resonator (FSRR) antenna for the purpose of radio communication with an animal-borne sensor. We show that the measurements agree with the simulated results and that we are able to produce an electrically small antenna with low mismatch, high radiation efficiency and a quasi-isotropic radiation pattern. We then adapt the topology of the design from a circular to a rectangular shape, to completely fit inside the sensor enclosure. A quasi-isotropic pattern is maintained as well as low mismatch by appropriate tuning. There is a decrease in radiation efficiency which may be countered by a thinner substrate and retuning. We conclude that the adapted FSRR antenna is a suitable design for our application.
Flores-Jiménez, Nancy G; Rojas-Lemus, Marcela; Fortoul, Teresa I; Zepeda-Rodríguez, Armando; López-Camacho, Perla Y; Anacleto-Santos, Jhony; Gutiérrez, Filiberto Malagón; Basurto-Islas, Gustavo; Rivera-Fernández, Norma
2018-06-20
The indiscriminate use of herbal products is increasingly growing worldwide; nonetheless consumers are not warned about the potential health risks that these products may cause. Hintonia latiflora (Hl) is a tree native to the American continent belonging to the Rubiaceae family and its stem bark is empirically used mainly to treat diabetes and malaria; supplements containing Hl are sold in America and Europe without medical prescription, thus scientific information regarding its toxicity as a consequence of a regular consumption is needed. In the present study, the histopathological effect of 200 and 1000 mg/kg of Hintonia latiflora methanolic stem bark extract (HlMeOHe) was evaluated in the small bowel, liver, pancreas, kidneys and brain of CD-1 male mice after oral sub-acute treatment for 28 days. No histopathological alterations were observed in the brain and small bowel of the treated animals; however, mice presented diarrhea from day 2 of treatment with both doses. No histological changes were observed in the tissues collected from the animals treated with 200 mg /kg, except for the liver that depicted periportal hepatitis. Animals treated with the higher dose showed in the liver sections hydropic degeneration, hepatitis and necrosis, kidney sections depicted tubular necrosis and in pancreas sections, hydropic degeneration of the pancreatic islets was observed. In conclusion, HlMeOHe damaged the liver with an oral dose of 200 mg/kg, and at 1000 mg/kg injured the kidneys and pancreas of the CD-1 male mice.
Gay, Wilfried; Lauret, Evelyne; Boson, Bertrand; Larghero, Jérome; Matheux, Franck; Peyramaure, Sophie; Rousseau, Véronique; Dormont, Dominique; De Maeyer, Edward; Le Grand, Roger
2004-01-01
Background The aim of this study was to evaluate gene therapy for AIDS based on the transduction of circulating lymphocytes with a retroviral vector giving low levels of constitutive macaque interferon β production in macaques chronically infected with a pathogenic isolate of SIVmac251. Results Two groups of three animals infected for more than one year with a pathogenic primary isolate of SIVmac251 were included in this study. The macaques received three infusions of their own lymphocytes transduced ex vivo with the construct encoding macaque IFN-β (MaIFN-β or with a vector carrying a version of the MaIFN-β gene with a deletion preventing translation of the mRNA. Cellular or plasma viremia increased transiently following injection in most cases, regardless of the retroviral construct used. Transduced cells were detected only transiently after each infusion, among the peripheral blood mononuclear cells of all the animals, with copy numbers of 10 to 1000 per 106 peripheral mononuclear cells. Conclusion Long-term follow-up indicated that the transitory presence of such a small number of cells producing such small amounts of MaIFN-β did not prevent animals from the progressive decrease in CD4+ cell count typical of infection with simian immunodeficiency virus. These results reveal potential pitfalls for future developments of gene therapy strategies of HIV infection. PMID:15447786
Experiment K-7-29: Connective Tissue Studies. Part 3; Rodent Tissue Repair: Skeletal Muscle
NASA Technical Reports Server (NTRS)
Stauber, W.; Fritz, V. K.; Burkovskaya, T. E.; Ilyina-Kakueva, E. I.
1994-01-01
Myofiber injury-repair was studied in the rat gastrocnemius following a crush injury to the lower leg prior to flight in order to understand if the regenerative responses of muscles are altered by the lack of gravitational forces during Cosmos 2044 flight. After 14 days of flight, the gastrocnemius muscle was removed from the 5 injured flight rodents and various Earth-based treatment groups for comparison. The Earth-based animals consisted of three groups of five rats with injured muscles from a simulated, tail-suspended, and vivarium as well as an uninjured basal group. The gastrocnemius muscle from each was evaluated by histochemical and immunohistochemical techniques to document myofiber, vascular, and connective tissue alterations following injury. In general the repair process was somewhat similar in all injured muscle samples with regard to extracellular matrix organization and myofiber regeneration. Small and large myofibers were present with a newly organized extracellular matrix indicative of myogenesis and muscle regeneration. In the tail-suspended animals, a more complete repair was observed with no enlarged area of non-muscle cells or matrix material visible. In contrast, the muscle samples from the flight animals were less well differentiated with more macrophages and blood vessels in the repair region but small myofibers and proteoglycans, nevertheless, were in their usual configuration. Thus, myofiber repair did vary in muscles from the different groups, but for the most part, resulted in functional muscle tissue.
DiFilippo, Frank P.
2008-01-01
A multi-pinhole collimation device is developed that uses the gamma camera detectors of a clinical SPECT or SPECT-CT scanner to produce high resolution SPECT images. The device consists of a rotating cylindrical collimator having 22 tungsten pinholes with 0.9 mm diameter apertures and an animal bed inside the collimator that moves linearly to provide helical or ordered-subsets axial sampling. CT images also may be acquired on a SPECT-CT scanner for purposes of image co-registration and SPECT attenuation correction. The device is placed on the patient table of the scanner without attaching to the detectors or scanner gantry. The system geometry is calibrated in-place from point source data and is then used during image reconstruction. The SPECT imaging performance of the device is evaluated with test phantom scans. Spatial resolution from reconstructed point source images is measured to be 0.6 mm full width at half maximum or better. Micro-Derenzo phantom images demonstrate the ability to resolve 0.7 mm diameter rod patterns. The axial slabs of a Micro-Defrise phantom are visualized well. Collimator efficiency exceeds 0.05% at the center of the field of view, and images of a uniform phantom show acceptable uniformity and minimal artifact. The overall simplicity and relatively good imaging performance of the device make it an interesting low-cost alternative to dedicated small animal scanners. PMID:18635899
Unmanned aircraft systems as a new source of disturbance for wildlife: A systematic review
Jenni-Eiermann, Susanne; Strebel, Nicolas; Sattler, Thomas; Negro, Juan José; Tablado, Zulima
2017-01-01
The use of small Unmanned Aircraft Systems (UAS; also known as “drones”) for professional and personal-leisure use is increasing enormously. UAS operate at low altitudes (<500 m) and in any terrain, thus they are susceptible to interact with local fauna, generating a new type of anthropogenic disturbance that has not been systematically evaluated. To address this gap, we performed a review of the existent literature about animals’ responses to UAS flights and conducted a pooled analysis of the data to determine the probability and intensity of the disturbance, and to identify the factors influencing animals’ reactions towards the small aircraft. We found that wildlife reactions depended on both the UAS attributes (flight pattern, engine type and size of aircraft) and the characteristics of animals themselves (type of animal, life-history stage and level of aggregation). Target-oriented flight patterns, larger UAS sizes, and fuel-powered (noisier) engines evoked the strongest reactions in wildlife. Animals during the non-breeding period and in large groups were more likely to show behavioral reactions to UAS, and birds are more prone to react than other taxa. We discuss the implications of these results in the context of wildlife disturbance and suggest guidelines for conservationists, users and manufacturers to minimize the impact of UAS. In addition, we propose that the legal framework needs to be adapted so that appropriate actions can be undertaken when wildlife is negatively affected by these emergent practices. PMID:28636611
Mucosal IgA increase in rats by continuous CLA feeding during suckling and early infancy.
Pérez-Cano, Francisco J; Ramírez-Santana, Carolina; Molero-Luís, Marta; Castell, Margarida; Rivero, Montserrat; Castellote, Cristina; Franch, Angels
2009-03-01
The aim of this work was to establish the effect of the cis9,trans11 conjugated linoleic acid (CLA) isomer on mucosal immunity during early life in rats, a period when mucosal immunoglobulin production is poorly developed, as is also the case in humans. CLA supplementation was performed during three life periods: gestation, suckling, and early infancy. The immune status of supplemented animals was evaluated at two time points: at the end of the suckling period (21-day-old rats) and 1 week after weaning (28-day-old rats). Secretory IgA was quantified in intestinal washes from 28-day-old rats by ELISA technique. IgA, TGFbeta, and PPARgamma mRNA expression was measured in small intestine and colon by real time PCR, using Taqman specific probes and primers. IgA mucosal production was enhanced in animals supplemented with CLA during suckling and early infancy: in 28-day-old rats, IgA mRNA expression was increased in small intestine and colon by approximately 6- and 4-fold, respectively, and intestinal IgA protein by approximately 2-fold. TGFbeta gene expression was independent of age and type of tissue considered, and was not modified by dietary CLA. Gene expression of PPARgamma, a possible mediator of CLA's effects was also upregulated in animals receiving CLA during early life. In conclusion, dietary supplementation with CLA during suckling and extended to early infancy enhances development of the intestinal immune response in rats.
Selection methods for resistance to and tolerance of helminths in livestock.
McManus, Concepta; do Prado Paim, Tiago; de Melo, Cristiano Barros; Brasil, Bruno S A F; Paiva, Samuel R
2014-01-01
Helminthiases are among the most important livestock diseases worldwide, in particular for small ruminants, which are the focus of this review. Resource Allocation Theory implies that high-productivity farm animals proportionate insufficient resources for adequate coping with stressful conditions. Significant differences between breeds and within breeds are seen, as well as genotype vs. environment interactions. With improvement of genetic host resistance to infection, transmission of infection will be impacted. On the other hand, genetic improvement of resilience can lead to a reduction in clinical signs of disease, but not necessarily reduce transmission of infection to other animals. Faecal egg count (FEC) is the main measurement used to evaluate helminthiasis load, despite the fact that the protocols and analytical methods can affect the results, and the FEC data frequently shows aggregative, negative skewed distribution, and a high coefficient of variation. Mass selection where heritability is generally medium to low generally produces slow results and low economic returns. Many studies have been published linking resistance to nematodes in livestock to Quantitative Trait Loci and most studies have concentrated on chromosomes where the major histocompatibility complex region is located. Nevertheless, these complex traits have been seen to be affected by thousands of variants that each has a small effect. More recent studies have shown that genome-wide selection strategies can be useful in selecting animals for improved production and resistance traits in this case. © C. McManus et al., published by EDP Sciences, 2014.
NASA Astrophysics Data System (ADS)
Di Filippo, Frank P.
2008-08-01
A multi-pinhole collimation device is developed that uses the gamma camera detectors of a clinical SPECT or SPECT-CT scanner to produce high-resolution SPECT images. The device consists of a rotating cylindrical collimator having 22 tungsten pinholes with 0.9 mm diameter apertures and an animal bed inside the collimator that moves linearly to provide helical or ordered-subsets axial sampling. CT images also may be acquired on a SPECT-CT scanner for purposes of image co-registration and SPECT attenuation correction. The device is placed on the patient table of the scanner without attaching to the detectors or scanner gantry. The system geometry is calibrated in-place from point source data and is then used during image reconstruction. The SPECT imaging performance of the device is evaluated with test phantom scans. Spatial resolution from reconstructed point source images is measured to be 0.6 mm full width at half maximum or better. Micro-Derenzo phantom images demonstrate the ability to resolve 0.7 mm diameter rod patterns. The axial slabs of a Micro-Defrise phantom are visualized well. Collimator efficiency exceeds 0.05% at the center of the field of view, and images of a uniform phantom show acceptable uniformity and minimal artifact. The overall simplicity and relatively good imaging performance of the device make it an interesting low-cost alternative to dedicated small animal scanners.
Geo-PET: A novel generic organ-pet for small animal organs and tissues
NASA Astrophysics Data System (ADS)
Sensoy, Levent
Reconstructed tomographic image resolution of small animal PET imaging systems is improving with advances in radiation detector development. However the trend towards higher resolution systems has come with an increase in price and system complexity. Recent developments in the area of solid-state photomultiplication devices like silicon photomultiplier arrays (SPMA) are creating opportunities for new high performance tools for PET scanner design. Imaging of excised small animal organs and tissues has been used as part of post-mortem studies in order to gain detailed, high-resolution anatomical information on sacrificed animals. However, this kind of ex-vivo specimen imaging has largely been limited to ultra-high resolution muCT. The inherent limitations to PET resolution have, to date, excluded PET imaging from these ex-vivo imaging studies. In this work, we leverage the diminishing physical size of current generation SPMA designs to create a very small, simple, and high-resolution prototype detector system targeting ex-vivo tomographic imaging of small animal organs and tissues. We investigate sensitivity, spatial resolution, and the reconstructed image quality of a prototype small animal PET scanner designed specifically for imaging of excised murine tissue and organs. We aim to demonstrate that a cost-effective silicon photomultiplier (SiPM) array based design with thin crystals (2 mm) to minimize depth of interaction errors might be able to achieve sub-millimeter resolution. We hypothesize that the substantial decrease in sensitivity associated with the thin crystals can be compensated for with increased solid angle detection, longer acquisitions, higher activity and wider acceptance energy windows (due to minimal scatter from excised organs). The constructed system has a functional field of view (FoV) of 40 mm diameter, which is adequate for most small animal specimen studies. We perform both analytical (3D-FBP) and iterative (ML-EM) methods in order to reconstruct tomographic images. Results demonstrate good agreement between the simulation and the prototype. Our detector system with pixelated crystals is able to separate small objects as close as 1.25 mm apart, whereas spatial resolution converges to the theoretical limit of 1.6 mm (half the size of the smallest detecting element), which is to comparable to the spatial resolution of the existing commercial small animal PET systems. Better system spatial resolution is achievable with new generation SiPM detector boards with 1 mm x 1 mm cell dimensions. We demonstrate through Monte Carlo simulations that it is possible to achieve sub-millimeter spatial image resolution (0.7 mm for our scanner) in complex objects using monolithic crystals and exploiting the light-sharing mechanism among the neighboring detector cells. Results also suggest that scanner (or object) rotation minimizes artifacts arising from poor angular sampling, which is even more significant in smaller PET designs as the gaps between the sensitive regions of the detector have a more exaggerated effect on the overall reconstructed image quality when the design is more compact. Sensitivity of the system, on the other hand, can be doubled by adding two additional detector heads resulting in a, fully closed, 4? geometry.
Cardiac Radionuclide Imaging in Rodents: A Review of Methods, Results, and Factors at Play
Cicone, Francesco; Viertl, David; Quintela Pousa, Ana Maria; Denoël, Thibaut; Gnesin, Silvano; Scopinaro, Francesco; Vozenin, Marie-Catherine; Prior, John O.
2017-01-01
The interest around small-animal cardiac radionuclide imaging is growing as rodent models can be manipulated to allow the simulation of human diseases. In addition to new radiopharmaceuticals testing, often researchers apply well-established probes to animal models, to follow the evolution of the target disease. This reverse translation of standard radiopharmaceuticals to rodent models is complicated by technical shortcomings and by obvious differences between human and rodent cardiac physiology. In addition, radionuclide studies involving small animals are affected by several extrinsic variables, such as the choice of anesthetic. In this paper, we review the major cardiac features that can be studied with classical single-photon and positron-emitting radiopharmaceuticals, namely, cardiac function, perfusion and metabolism, as well as the results and pitfalls of small-animal radionuclide imaging techniques. In addition, we provide a concise guide to the understanding of the most frequently used anesthetics such as ketamine/xylazine, isoflurane, and pentobarbital. We address in particular their mechanisms of action and the potential effects on radionuclide imaging. Indeed, cardiac function, perfusion, and metabolism can all be significantly affected by varying anesthetics and animal handling conditions. PMID:28424774
A new class of animal collagen masquerading as an insect silk
Sutherland, Tara D.; Peng, Yong Y.; Trueman, Holly E.; Weisman, Sarah; Okada, Shoko; Walker, Andrew A.; Sriskantha, Alagacone; White, Jacinta F.; Huson, Mickey G.; Werkmeister, Jerome A.; Glattauer, Veronica; Stoichevska, Violet; Mudie, Stephen T.; Haritos, Victoria S.; Ramshaw, John A. M.
2013-01-01
Collagen is ubiquitous throughout the animal kingdom, where it comprises some 28 diverse molecules that form the extracellular matrix within organisms. In the 1960s, an extracorporeal animal collagen that forms the cocoon of a small group of hymenopteran insects was postulated. Here we categorically demonstrate that the larvae of a sawfly species produce silk from three small collagen proteins. The native proteins do not contain hydroxyproline, a post translational modification normally considered characteristic of animal collagens. The function of the proteins as silks explains their unusual collagen features. Recombinant proteins could be produced in standard bacterial expression systems and assembled into stable collagen molecules, opening the door to manufacture a new class of artificial collagen materials. PMID:24091725
Utilization and cost of log production from animal loging operations
Suraj P. Shrestha; Bobby L. Lanford; Robert B. Rummer; Mark Dubois
2006-01-01
Forest harvesting with animals is a labor-intensive operation. It is expensive to use machines on smaller woodlots, which require frequent moves if mechanically logged. So, small logging systems using animals may be more cost effective. In this study, work sampling was used for five animal logging operations in Alabama to measure productive and non-productive time...
A survey of animal-powered logging in Alabama
Christopher W. Toms; Mark R. Dubois; John C. Bliss; John H. Wilhoit; Robert B. Rummer
2001-01-01
In a state with a very large, highly mechanized timber harvesting industry, animal-powered logging still occupies a niche in Alabama as a small-scale harvesting alternative. This article summarizes the results from a study that examined the extent of animal logging in Alabama. We investigated this topic by asking who is logging with animals, where are they working,...
Practices in Wound Healing Studies of Plants
Thakur, Rupesh; Jain, Nitika; Pathak, Raghvendra; Sandhu, Sardul Singh
2011-01-01
Wounds are the result of injuries to the skin that disrupt the other soft tissue. Healing of a wound is a complex and protracted process of tissue repair and remodeling in response to injury. Various plant products have been used in treatment of wounds over the years. Wound healing herbal extracts promote blood clotting, fight infection, and accelerate the healing of wounds. Phytoconstituents derived from plants need to be identified and screened for antimicrobial activity for management of wounds. The in vitro assays are useful, quick, and relatively inexpensive. Small animals provide a multitude of model choices for various human wound conditions. The study must be conducted after obtaining approval of the Ethics Committee and according to the guidelines for care and use of animals. The prepared formulations of herbal extract can be evaluated by various physicopharmaceutical parameters. The wound healing efficacies of various herbal extracts have been evaluated in excision, incision, dead space, and burn wound models. In vitro and in vivo assays are stepping stones to well-controlled clinical trials of herbal extracts. PMID:21716711
The zoonotic potential of Clostridium difficile from small companion animals and their owners.
Rabold, Denise; Espelage, Werner; Abu Sin, Muna; Eckmanns, Tim; Schneeberg, Alexander; Neubauer, Heinrich; Möbius, Nadine; Hille, Katja; Wieler, Lothar H; Seyboldt, Christian; Lübke-Becker, Antina
2018-01-01
Clostridium difficile infections (CDI) in humans range from asymptomatic carriage to life-threatening intestinal disease. Findings on C. difficile in various animal species and an overlap in ribotypes (RTs) suggest potential zoonotic transmission. However, the impact of animals for human CDI remains unclear. In a large-scale survey we collected 1,447 fecal samples to determine the occurrence of C. difficile in small companion animals (dogs and cats) and their owners and to assess potential epidemiological links within the community. The Germany-wide survey was conducted from July 2012-August 2013. PCR ribotyping, Multilocus VNTR Analysis (MLVA) and PCR detection of toxin genes were used to characterize isolated C. difficile strains. A database was defined and logistic regression used to identify putative factors associated with fecal shedding of C. difficile. In total, 1,418 samples met the inclusion criteria. The isolation rates for small companion animals and their owners within the community were similarly low with 3.0% (25/840) and 2.9% (17/578), respectively. PCR ribotyping revealed eight and twelve different RTs in animals and humans, respectively, whereas three RTs were isolated in both, humans and animals. RT 014/0, a well-known human hospital-associated lineage, was predominantly detected in animal samples. Moreover, the potentially highly pathogenic RTs 027 and 078 were isolated from dogs. Even though, C. difficile did not occur simultaneously in animals and humans sharing the same household. The results of the epidemiological analysis of factors associated with fecal shedding of C. difficile support the hypothesis of a zoonotic potential. Molecular characterization and epidemiological analysis revealed that the zoonotic risk for C. difficile associated with dogs and cats within the community is low but cannot be excluded.
MR images of mouse brain using clinical 3T MR scanner and 4CH-Mouse coil
NASA Astrophysics Data System (ADS)
Lim, Soo Mee; Park, Eun Mi; Lyoo, In Kyoon; Lee, Junghyun; Han, Bo Mi; Lee, Jeong Kyong; Lee, Su Bin
2015-07-01
Objectives: Although small-bore high-field magnets are useful for research in small rodent models,this technology, however, has not been easily accessible to most researchers. This current study, thus,tried to evaluate the usability of 4CH-Mouse coil (Philips Healthcare, Best, the Netherlands) forpreclinical investigations in clinical 3T MR scan environment. We evaluated the effects of ischemicpreconditioning (IP) in the mouse stroke model with clinical 3T MR scanner and 4CH-Mouse coil. Materials and Methods: Experiments were performed on male C57BL/6 mice that either received the IP or sham operation (control). Three different MR sequences including diffusion weighted images (DWI), T2-weighted images (T2WI), and fluid attenuated inversion recovery (FLAIR) were performed on the mouse brains following 24, 72 hours of middle cerebral artery occlusion (MCAO) and analyzed for infarct lesions. Results: The images showed that the IP-treated mouse brains had significantly smaller infarct volumes compared to the control group. Of the MR sequences employed, the T2WI showed the highest level of correlations with postmortem infarct volume measurements. Conclusions: The clinical 3T MR scanner turned out to have a solid potential as a practical tool for imaging small animal brains. MR sequences including DWI, T2WI, FLAIR were obtained with acceptable resolution and in a reasonable time constraint in evaluating a mouse stroke model brain.
Meyer, Allison M; Caton, Joel S
2016-01-01
Small-intestinal growth and function are critical for optimal animal growth and health and play a major role in nutrient digestion and absorption, energy and nutrient expenditure, and immunological competence. During fetal and perinatal development, the small intestine is affected by the maternal environment and nutrient intake. In ruminants, altered small-intestinal mass, villi morphology, hypertrophy, hyperplasia, vascularity, and gene expression have been observed as a result of poor gestational nutrition or intrauterine growth restriction. Although many of these data come from fetal stages, data have also demonstrated that nutrition during mid- and late gestation affects lamb small-intestinal growth, vascularity, digestive enzyme activity, and gene expression at 20 and 180 d of age as well. The small intestine is known to be a highly plastic tissue, changing with nutrient intake and physiological state even in adulthood, and the maternal small intestine adapts to pregnancy and advancing gestation. In ruminants, the growth, vascularity, and gene expression of the maternal small intestine also adapt to the nutritional plane and specific nutrient intake such as high selenium during pregnancy. These changes likely alter both pre- and postnatal nutrient delivery to offspring. More research is necessary to better understand the role of the offspring and maternal small intestines in whole-animal responses to developmental programming, but programming of this plastic tissue seems to play a dynamic role in gestational nutrition impacts on the whole animal. PMID:27180380
Noninvasive Raman spectroscopy of rat tibiae: approach to in vivo assessment of bone quality
Okagbare, Paul I.; Begun, Dana; Tecklenburg, Mary; Awonusi, Ayorinde; Goldstein, Steven A.
2012-01-01
Abstract. We report on in vivo noninvasive Raman spectroscopy of rat tibiae using robust fiber-optic Raman probes and holders designed for transcutaneous Raman measurements in small animals. The configuration allows placement of multiple fibers around a rat leg, maintaining contact with the skin. Bone Raman data are presented for three regions of the rat tibia diaphysis with different thicknesses of overlying soft tissue. The ability to perform in vivo noninvasive Raman measurement and evaluation of subtle changes in bone composition is demonstrated with rat leg phantoms in which the tibia has carbonated hydroxylapatite, with different carbonate contents. Our data provide proof of the principle that small changes in bone composition can be monitored through soft tissue at anatomical sites of interest in biomedical studies. PMID:23085899
Noninvasive Raman spectroscopy of rat tibiae: approach to in vivo assessment of bone quality.
Okagbare, Paul I; Begun, Dana; Tecklenburg, Mary; Awonusi, Ayorinde; Goldstein, Steven A; Morris, Michael D
2012-09-01
We report on in vivo noninvasive Raman spectroscopy of rat tibiae using robust fiber-optic Raman probes and holders designed for transcutaneous Raman measurements in small animals. The configuration allows placement of multiple fibers around a rat leg, maintaining contact with the skin. Bone Raman data are presented for three regions of the rat tibia diaphysis with different thicknesses of overlying soft tissue. The ability to perform in vivo noninvasive Raman measurement and evaluation of subtle changes in bone composition is demonstrated with rat leg phantoms in which the tibia has carbonated hydroxylapatite, with different carbonate contents. Our data provide proof of the principle that small changes in bone composition can be monitored through soft tissue at anatomical sites of interest in biomedical studies.
A Multi-Mode Shock Tube for Investigation of Blast-Induced Traumatic Brain Injury
Reneer, Dexter V.; Hisel, Richard D.; Hoffman, Joshua M.; Kryscio, Richard J.; Lusk, Braden T.
2011-01-01
Abstract Blast-induced mild traumatic brain injury (bTBI) has become increasingly common in recent military conflicts. The mechanisms by which non-impact blast exposure results in bTBI are incompletely understood. Current small animal bTBI models predominantly utilize compressed air-driven membrane rupture as their blast wave source, while large animal models use chemical explosives. The pressure-time signature of each blast mode is unique, making it difficult to evaluate the contributions of the different components of the blast wave to bTBI when using a single blast source. We utilized a multi-mode shock tube, the McMillan blast device, capable of utilizing compressed air- and compressed helium-driven membrane rupture, and the explosives oxyhydrogen and cyclotrimethylenetrinitramine (RDX, the primary component of C-4 plastic explosives) as the driving source. At similar maximal blast overpressures, the positive pressure phase of compressed air-driven blasts was longer, and the positive impulse was greater, than those observed for shockwaves produced by other driving sources. Helium-driven shockwaves more closely resembled RDX blasts, but by displacing air created a hypoxic environment within the shock tube. Pressure-time traces from oxyhydrogen-driven shockwaves were very similar those produced by RDX, although they resulted in elevated carbon monoxide levels due to combustion of the polyethylene bag used to contain the gases within the shock tube prior to detonation. Rats exposed to compressed air-driven blasts had more pronounced vascular damage than those exposed to oxyhydrogen-driven blasts of the same peak overpressure, indicating that differences in blast wave characteristics other than peak overpressure may influence the extent of bTBI. Use of this multi-mode shock tube in small animal models will enable comparison of the extent of brain injury with the pressure-time signature produced using each blast mode, facilitating evaluation of the blast wave components contributing to bTBI. PMID:21083431
Miyake, Masateru; Koga, Toshihisa; Kondo, Satoshi; Yoda, Noriaki; Emoto, Chie; Mukai, Tadashi; Toguchi, Hajime
2017-01-01
An adequate evaluation system for drug intestinal absorption is essential in the pharmaceutical industry. Previously, we established a novel prediction system of drug intestinal absorption in humans, using the mini-Ussing chamber equipped with human intestinal tissues. In this system, the TI value was defined as the sum of drug amounts transported to the basal-side component (X corr ) and drug amounts accumulated in the tissue (T corr ), which are normalized by AUC of a drug in the apical compartment, as an index for drug absorption. In order to apply this system to the screening assay, it is important to understand the differences between animal and human tissues in the intestinal absorption of drugs. In this study, the transport index (TI) values of three drugs, with different levels of membrane permeability, were determined to evaluate the rank order of drug absorbability in intestinal tissues from rats, dogs, and monkeys. The TI values in small intestinal tissues in rats and dogs showed a good correlation with those in humans. On the other hand, the correlation of TI values in monkeys was lower compared to rats and dogs. The rank order of the correlation coefficient between human and investigated animal tissues was as follows: dog (r 2 =0.978), rat (r 2 =0.955), and monkey (r 2 =0.620). TI values in large intestinal tissues from rats (r 2 =0.929) and dogs (r 2 =0.808) also showed a good correlation. The obtained TI values in small intestinal tissues in rats and dogs were well correlated with the fraction of drug absorbed (F a ) in humans. From these results, the mini-Ussing chamber, equipped with intestinal tissues in rats and dogs, would be useful as a screening tool in the drug discovery stage. In addition, the obtained TI values can be used for the prediction of the F a in humans. Copyright © 2016 Elsevier B.V. All rights reserved.
A multi-mode shock tube for investigation of blast-induced traumatic brain injury.
Reneer, Dexter V; Hisel, Richard D; Hoffman, Joshua M; Kryscio, Richard J; Lusk, Braden T; Geddes, James W
2011-01-01
Blast-induced mild traumatic brain injury (bTBI) has become increasingly common in recent military conflicts. The mechanisms by which non-impact blast exposure results in bTBI are incompletely understood. Current small animal bTBI models predominantly utilize compressed air-driven membrane rupture as their blast wave source, while large animal models use chemical explosives. The pressure-time signature of each blast mode is unique, making it difficult to evaluate the contributions of the different components of the blast wave to bTBI when using a single blast source. We utilized a multi-mode shock tube, the McMillan blast device, capable of utilizing compressed air- and compressed helium-driven membrane rupture, and the explosives oxyhydrogen and cyclotrimethylenetrinitramine (RDX, the primary component of C-4 plastic explosives) as the driving source. At similar maximal blast overpressures, the positive pressure phase of compressed air-driven blasts was longer, and the positive impulse was greater, than those observed for shockwaves produced by other driving sources. Helium-driven shockwaves more closely resembled RDX blasts, but by displacing air created a hypoxic environment within the shock tube. Pressure-time traces from oxyhydrogen-driven shockwaves were very similar those produced by RDX, although they resulted in elevated carbon monoxide levels due to combustion of the polyethylene bag used to contain the gases within the shock tube prior to detonation. Rats exposed to compressed air-driven blasts had more pronounced vascular damage than those exposed to oxyhydrogen-driven blasts of the same peak overpressure, indicating that differences in blast wave characteristics other than peak overpressure may influence the extent of bTBI. Use of this multi-mode shock tube in small animal models will enable comparison of the extent of brain injury with the pressure-time signature produced using each blast mode, facilitating evaluation of the blast wave components contributing to bTBI.
Design, construction and testing of a DC bioeffects test enclosure for small animals. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frazier, M J; Preache, M M
1980-11-01
This final report describes both the engineering development of a DC bioeffects test enclosure for small laboratory animals, and the biological protocol for the use of such enclosures in the testing of animals to determine possible biological effects of the environment associated with HVDC transmission lines. The test enclosure which has been designed is a modular unit, which will house up to eight rat-sized animals in individual compartments. Multiple test enclosures can be used to test larger numbers of animals. A prototype test enclosure has been fabricated and tested to characterize its electrical performance characteristics. The test enclosure provides amore » simulation of the dominant environment associated with HVDC transmission lines; namely, a static electric field and an ion current density. A biological experimental design has been developed for assessing the effects of the dominant components of the HVDC transmission line environment.« less
Domestic animals as carriers of Bordetella species in Senegal.
Ngom, Abdoulaye; Boulanger, Denis; Ndiaye, Tofène; Mboup, Souleymane; Bada-Alambedji, Rianatou; Simondon, François; Ayih-Akakpo, Ayayi Justin
2006-01-01
Despite intense efforts to maintain a high level of vaccine coverage against human whooping cough, rural senegalese areas are still endemic for Bordetella pertussis. One explanation being the potential existence of animal reservoirs, the objective of this work was to precise the carriage by domestic animals of bacteria belonging to the genus Bordetella in Senegal. Bacteriological samples (swabs and aspirates) were obtained from various domestic animals living in different parts of the country. No B. pertussis nor B. parapertussis were isolated. However, for the first time to our knowledge, B. bronchiseptica was identified from small ruminants located in Africa. The positive animals were two goats and two sheep from Dakar slaughterhouse together with a goat living in a rural compound. The fact that it was identified in goats and sheep underlines the potential zoonotic of that bacterial species in countries where small ruminants are of economical and cultural relevance.
Inhalation toxicity studies: OECD guidelines in relation to REACH and scientific developments.
Arts, Josje H E; Muijser, H; Jonker, D; van de Sandt, J J M; Bos, P M J; Feron, V J
2008-06-01
The OECD Health Effects Test Guidelines (TGs) provide guidance concerning the use of methods for the identification and characterization of hazards from chemical substances. These TGs are largely based on tests in routine use for many years and are known to yield information relevant to various types of toxicity. They have proven their value in practice and will remain of paramount importance for decades to come. However, the TGs describe mostly animal assays, and there is an increasingly strong urge to reduce animal testing on ethical grounds. In addition, assessment procedures are generally considered too slow and too rigid, which has resulted in elaborate testing of a relatively small number of chemicals, while virtually nothing is known about the vast majority of compounds. The major objectives of Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) are to improve the knowledge about the properties and use of chemicals and to speed up the procedure of risk assessment. The REACH text contains information requirements that can be met by OECD TGs but REACH also provides rules for adaptation of the standard testing regime. Also, various components of "Intelligent Testing Strategies" are described in order to limit animal testing. This paper briefly describes the OECD TGs for inhalation toxicity studies, including those in preparation, and their role in future hazard identification. This will be discussed in relation to the evaluation of the safety of thousands of chemicals in a relatively short period of time and scientific developments, including the use of alternatives to animal testing.
SCG/Kinjoh mice: a model of ANCA-associated crescentic glomerulonephritis with immune deposits.
Neumann, Irmgard; Birck, Rainer; Newman, Mark; Schnülle, Peter; Kriz, Wilhelm; Nemoto, Kyuichi; Yard, Benito; Waldherr, Rüdiger; Van Der Woude, Fokko J
2003-07-01
Spontaneous crescentic glomerulonephritis-forming/Kinjoh (SCG/Kj) mice spontaneously develop crescentic glomerulonephritis (CGN), systemic vasculitis, and perinuclear ANCA (pANCA), and have been suggested as an animal model for human antineutrophil cytoplasmic antibody (ANCA)-associated vasculitis (AASV). Since no systematic serologic, immunohistologic, or structural evaluation had been performed thus far, we reinvestigated the development of ANCA and CGN in these mice. SCG/Kj mice were subjected to serologic and urinary analysis, as well as histologic evaluation of the kidneys by standard light, immunofluorescence, and electron microscopy at regular intervals during the course of the disease. Perinuclear ANCA developed as early as the 6th week of life, increasing both in frequency and titer in up to 100% of animals at week 20. Crescent formation began at week 10 and peaked at week 16, maximally affecting 57% of glomeruli. Crescent formation was initiated by "activated" podocytes that formed cell bridges between tuft and Bowman's capsule. The typical picture of a diffuse immune complex nephritis was found in all animals as early as 8 weeks. Fluorescence intensity increased with age and became strongly positive for immunoglobulin (Ig)A, IgM, IgG, and C3 in the mesangium and along the peripheral capillary loops. Although ANCAs were found in the majority of animals, the massive presence of glomerular immune deposits differed from the pauci-immune pattern found in human AASV, making this model not completely representative for human ANCA-associated CGN. However, the spontaneous and concomitant development of pANCA, small vessel vasculitis, and CGN raises the opportunity to analyze pathogenetic links between these disease manifestations in vivo.
Paprottka, P M; Zengel, P; Cyran, C C; Ingrisch, M; Nikolaou, K; Reiser, M F; Clevert, D A
2014-01-01
To evaluate the ultrasound tissue elasticity imaging by comparison to multimodality imaging using image fusion with Magnetic Resonance Imaging (MRI) and conventional grey scale imaging with additional elasticity-ultrasound in an experimental small-animal-squamous-cell carcinoma-model for the assessment of tissue morphology. Human hypopharynx carcinoma cells were subcutaneously injected into the left flank of 12 female athymic nude rats. After 10 days (SD ± 2) of subcutaneous tumor growth, sonographic grey scale including elasticity imaging and MRI measurements were performed using a high-end ultrasound system and a 3T MR. For image fusion the contrast-enhanced MRI DICOM data set was uploaded in the ultrasonic device which has a magnetic field generator, a linear array transducer (6-15 MHz) and a dedicated software package (GE Logic E9), that can detect transducers by means of a positioning system. Conventional grey scale and elasticity imaging were integrated in the image fusion examination. After successful registration and image fusion the registered MR-images were simultaneously shown with the respective ultrasound sectional plane. Data evaluation was performed using the digitally stored video sequence data sets by two experienced radiologist using a modified Tsukuba Elasticity score. The colors "red and green" are assigned for an area of soft tissue, "blue" indicates hard tissue. In all cases a successful image fusion and plan registration with MRI and ultrasound imaging including grey scale and elasticity imaging was possible. The mean tumor volume based on caliper measurements in 3 dimensions was ~323 mm3. 4/12 rats were evaluated with Score I, 5/12 rates were evaluated with Score II, 3/12 rates were evaluated with Score III. There was a close correlation in the fused MRI with existing small necrosis in the tumor. None of the scored II or III lesions was visible by conventional grey scale. The comparison of ultrasound tissue elasticity imaging enables a secure differentiation between different tumor tissue areas in comparison to image fusion with MRI in our small study group. Therefore ultrasound tissue elasticity imaging might be used for fast detection of tumor response in the future whereas conventional grey scale imaging alone could not provide the additional information. By using standard, contrast-enhanced MRI images for reliable and reproducible slice positioning, the strongly user-dependent limitation of ultrasound tissue elasticity imaging may be overcome, especially for a comparison between baseline and follow-up measurements.
1982-03-01
plyethylene PVC landfill- HypalonM PE, CPE, neoprene, EPDM ,* bentqcnite ethylene propylene rubber elasticized polvoleiin 20. A94V C? (Coit" an 0*V" aid...materials include Hyralon®, butyl rubber , EPDM , CPE, neo- prene, polyethylene, polypropylene, PVC8 and elasticized polyolefin. With all of these...and animal and vegetable fats and oils (Geswein, 1975). EPDM , or etiylene propylene rubber , is a terpolymer of ethylene, propylene and a small amount
Seifertová, Marta; Čechová, Eliška; Llansola, Marta; Felipo, Vicente; Vykoukalová, Martina; Kočan, Anton
2017-10-01
We developed a simple analytical method for the simultaneous determination of representatives of various groups of neurotoxic insecticides (carbaryl, chlorpyrifos, cypermethrin, and α-endosulfan and β-endosulfan and their metabolite endosulfan sulfate) in limited amounts of animal tissues containing different amounts of lipids. Selected tissues (rodent fat, liver, and brain) were extracted in a special in-house-designed mini-extractor constructed on the basis of the Soxhlet and Twisselmann extractors. A dried tissue sample placed in a small cartridge was extracted, while the nascent extract was simultaneously filtered through a layer of sodium sulfate. The extraction was followed by combined clean-up, including gel permeation chromatography (in case of high lipid content), ultrasonication, and solid-phase extraction chromatography using C 18 on silica and aluminum oxide. Gas chromatography coupled with high-resolution mass spectrometry was used for analyte separation, detection, and quantification. Average recoveries for individual insecticides ranged from 82 to 111%. Expanded measurement uncertainties were generally lower than 35%. The developed method was successfully applied to rat tissue samples obtained from an animal model dealing with insecticide exposure during brain development. This method may also be applied to the analytical treatment of small amounts of various types of animal and human tissue samples. A significant advantage achieved using this method is high sample throughput due to the simultaneous treatment of many samples. Graphical abstract Optimized workflow for the determination of selected insecticides in small amounts of animal tissue including newly developed mini-extractor.
Kipperman, Barry; Morris, Patricia; Rollin, Bernard
2018-05-12
Small animal veterinarians' opinions were investigated regarding the frequency and nature of ethical dilemmas encountered, beliefs regarding euthanasia and balancing client and animal interests, prevalence and value of ethics training and proposals to mitigate the stressful effects of ethical dilemmas. The majority (52 per cent) of 484 respondents in the USA indicated via an online survey experiencing an ethical dilemma regarding the interests of clients and those of their patients at least weekly. Scenarios involving client financial concerns were commonly reported causes of ethical conflicts. While only 20 per cent of respondents indicated that other practitioners prioritise patient interests, 50 per cent of respondents characterised their own behaviour as prioritising patients. Most respondents (52 per cent) reported that ethical dilemmas are the leading cause, or are one of many equal causes, of work-related stress. Less experienced practitioners, general practitioners and associate veterinarians were more likely to encounter situations they defined as ethical dilemmas, and female respondents were more likely to find ethical dilemmas stressful. Most small animal veterinarians experience ethical dilemmas regularly, which contribute to moral stress. Results suggested that most small animal practitioners believe that greater awareness of moral stress and providing training in ethical theories and tools for coping with ethical dilemmas can ameliorate moral stress. © British Veterinary Association (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Ultrasonographic anatomy of bearded dragons (Pogona vitticeps).
Bucy, Daniel S; Guzman, David Sanchez-Migallon; Zwingenberger, Allison L
2015-04-15
To determine which organs can be reliably visualized ultrasonographically in bearded dragons (Pogona vitticeps), describe their normal ultrasonographic appearance, and describe an ultrasonographic technique for use with this species. Cross-sectional study. 14 healthy bearded dragons (6 females and 8 males). Bearded dragons were manually restrained in dorsal and sternal recumbency, and coelomic organs were evaluated by use of linear 7- to 15-MHz and microconvex 5- to 8-MHz transducers. Visibility, size, echogenicity, and ultrasound transducer position were assessed for each organ. Coelomic ultrasonography with both microconvex and linear ultrasound transducers allowed for visualization of the heart, pleural surface of the lungs, liver, caudal vena cava, aorta, ventral abdominal vein, gallbladder, fat bodies, gastric fundus, cecum, colon, cloaca, kidneys, and testes or ovaries in all animals. The pylorus was visualized in 12 of 14 animals. The small intestinal loops were visualized in 12 of 14 animals with the linear transducer, but could not be reliably identified with the microconvex transducer. The hemipenes were visualized in 7 of 8 males. The adrenal glands and spleen were not identified in any animal. Anechoic free coelomic fluid was present in 11 of 14 animals. Heart width, heart length, ventricular wall thickness, gastric fundus wall thickness, and height of the caudal poles of the kidneys were positively associated with body weight. Testis width was negatively associated with body weight in males. Results indicated coelomic ultrasonography is a potentially valuable imaging modality for assessment of most organs in bearded dragons and can be performed in unsedated animals.
Closing the phosphorus cycle in a food system: insights from a modelling exercise.
van Kernebeek, H R J; Oosting, S J; van Ittersum, M K; Ripoll-Bosch, R; de Boer, I J M
2018-05-21
Mineral phosphorus (P) used to fertilise crops is derived from phosphate rock, which is a finite resource. Preventing and recycling mineral P waste in the food system, therefore, are essential to sustain future food security and long-term availability of mineral P. The aim of our modelling exercise was to assess the potential of preventing and recycling P waste in a food system, in order to reduce the dependency on phosphate rock. To this end, we modelled a hypothetical food system designed to produce sufficient food for a fixed population with a minimum input requirement of mineral P. This model included representative crop and animal production systems, and was parameterised using data from the Netherlands. We assumed no import or export of feed and food. We furthermore assumed small P soil losses and no net P accumulation in soils, which is typical for northwest European conditions. We first assessed the minimum P requirement in a baseline situation, that is 42% of crop waste is recycled, and humans derived 60% of their dietary protein from animals (PA). Results showed that about 60% of the P waste in this food system resulted from wasting P in human excreta. We subsequently evaluated P input for alternative situations to assess the (combined) effect of: (1) preventing waste of crop and animal products, (2) fully recycling waste of crop products, (3) fully recycling waste of animal products and (4) fully recycling human excreta and industrial processing water. Recycling of human excreta showed most potential to reduce P waste from the food system, followed by prevention and finally recycling of agricultural waste. Fully recycling P could reduce mineral P input by 90%. Finally, for each situation, we studied the impact of consumption of PA in the human diet from 0% to 80%. The optimal amount of animal protein in the diet depended on whether P waste from animal products was prevented or fully recycled: if it was, then a small amount of animal protein in the human diet resulted in the most sustainable use of P; but if it was not, then the most sustainable use of P would result from a complete absence of animal protein in the human diet. Our results apply to our hypothetical situation. The principles included in our model however, also hold for food systems with, for example, different climatic and soil conditions, farming practices, representative types of crops and animals and population densities.
Introducing Therioepistemology: the study of how knowledge is gained from animal research.
Garner, Joseph P; Gaskill, Brianna N; Weber, Elin M; Ahloy-Dallaire, Jamie; Pritchett-Corning, Kathleen R
2017-03-22
This focus issue of Lab Animal coincides with a tipping point in biomedical research. For the first time, the scale of the reproducibility and translatability crisis is widely understood beyond the small cadre of researchers who have been studying it and the pharmaceutical and biotech companies who have been living it. Here we argue that an emerging literature, including the papers in this focus issue, has begun to congeal around a set of recurring themes, which themselves represent a paradigm shift. This paradigm shift can be characterized at the micro level as a shift from asking "what have we controlled for in this model?" to asking "what have we chosen to ignore in this model, and at what cost?" At the macro level, it is a shift from viewing animals as tools (the furry test tube), to viewing them as patients in an equivalent human medical study. We feel that we are witnessing the birth of a new discipline, which we term Therioepistemology, or the study of how knowledge is gained from animal research. In this paper, we outline six questions that serve as a heuristic for critically evaluating animal-based biomedical research from a therioepistemological perspective. These six questions sketch out the broad reaches of this new discipline, though they may change or be added to as this field evolves. Ultimately, by formalizing therioepistemology as a discipline, we can begin to discuss best practices that will improve the reproducibility and translatability of animal-based research, with concomitant benefits in terms of human health and animal well-being.
Topashka-Ancheva, Margarita; Beltcheva, Michaela; Metcheva, Roumiana; Rojas, J Antonio Heredia; Rodriguez-De la Fuente, Abraham O; Gerasimova, Tsvetelina; Rodríguez-Flores, Laura E; Teodorova, Svetla E
2012-06-01
The detoxification capacity of the clinoptilolite modification KLS-10-MA used as food additive in small mammals, chronically lead-exposed, was proven for the first time. The modified clinoptilolite was prepared based on natural Bulgarian clinoptilolite deposits. As a powder, it was mechanically mixed at 12.5% concentration with the conventional forage for small rodents. Lead in the form of aqueous solution of Pb(NO(3))(2) was diluted in the drinking water. In the ecotoxicological experiment covering 90 days, imprinting control region laboratory mice were used. They were allocated into four groups: group 1, (control): animals fed with conventional food for small rodents and water; group 2: animals fed with conventional food + clinosorbent KLS-10-MA and water; group 3: animals fed with conventional food and water + Pb(NO(3))(2); and group 4: animals fed with conventional food + KLS-10-MA and water + Pb(NO(3))(2). A group of non-exposed healthy animals was fed with conventional forage mixed with KLS-10-MA to prove eventual toxicity of the sorbent and influence on growth performance. The changes in the chromosome structure, mitotic index, erythrocyte form, erythropoiesis, and body weight gain were recorded. On day 90, the following relations were established: Pb-exposed and clinoptilolite-supplemented mice exhibited 2.3-fold lower chromosome aberrations frequency, 2.5-fold higher mitotic index, and 1.5-fold higher percentage normal erythrocytes 1.3-fold higher body weight compared to Pb-exposed and unsupplemented animals. The obtained data showed that the sorbent is practically non-toxic. The results of the present study encourage a further elaboration of a reliable drug based on the tested substance in the cases of chronic lead intoxication.
Borggren, Marie; Vinner, Lasse; Andresen, Betina Skovgaard; Grevstad, Berit; Repits, Johanna; Melchers, Mark; Elvang, Tara Laura; Sanders, Rogier W; Martinon, Frédéric; Dereuddre-Bosquet, Nathalie; Bowles, Emma Joanne; Stewart-Jones, Guillaume; Biswas, Priscilla; Scarlatti, Gabriella; Jansson, Marianne; Heyndrickx, Leo; Grand, Roger Le; Fomsgaard, Anders
2013-07-19
HIV-1 DNA vaccines have many advantageous features. Evaluation of HIV-1 vaccine candidates often starts in small animal models before macaque and human trials. Here, we selected and optimized DNA vaccine candidates through systematic testing in rabbits for the induction of broadly neutralizing antibodies (bNAb). We compared three different animal models: guinea pigs, rabbits and cynomolgus macaques. Envelope genes from the prototype isolate HIV-1 Bx08 and two elite neutralizers were included. Codon-optimized genes, encoded secreted gp140 or membrane bound gp150, were modified for expression of stabilized soluble trimer gene products, and delivered individually or mixed. Specific IgG after repeated i.d. inoculations with electroporation confirmed in vivo expression and immunogenicity. Evaluations of rabbits and guinea pigs displayed similar results. The superior DNA construct in rabbits was a trivalent mix of non-modified codon-optimized gp140 envelope genes. Despite NAb responses with some potency and breadth in guinea pigs and rabbits, the DNA vaccinated macaques displayed less bNAb activity. It was concluded that a trivalent mix of non-modified gp140 genes from rationally selected clinical isolates was, in this study, the best option to induce high and broad NAb in the rabbit model, but this optimization does not directly translate into similar responses in cynomolgus macaques.
Borggren, Marie; Vinner, Lasse; Andresen, Betina Skovgaard; Grevstad, Berit; Repits, Johanna; Melchers, Mark; Elvang, Tara Laura; Sanders, Rogier W; Martinon, Frédéric; Dereuddre-Bosquet, Nathalie; Bowles, Emma Joanne; Stewart-Jones, Guillaume; Biswas, Priscilla; Scarlatti, Gabriella; Jansson, Marianne; Heyndrickx, Leo; Le Grand, Roger; Fomsgaard, Anders
2013-01-01
HIV-1 DNA vaccines have many advantageous features. Evaluation of HIV-1 vaccine candidates often starts in small animal models before macaque and human trials. Here, we selected and optimized DNA vaccine candidates through systematic testing in rabbits for the induction of broadly neutralizing antibodies (bNAb). We compared three different animal models: guinea pigs, rabbits and cynomolgus macaques. Envelope genes from the prototype isolate HIV-1 Bx08 and two elite neutralizers were included. Codon-optimized genes, encoded secreted gp140 or membrane bound gp150, were modified for expression of stabilized soluble trimer gene products, and delivered individually or mixed. Specific IgG after repeated i.d. inoculations with electroporation confirmed in vivo expression and immunogenicity. Evaluations of rabbits and guinea pigs displayed similar results. The superior DNA construct in rabbits was a trivalent mix of non-modified codon-optimized gp140 envelope genes. Despite NAb responses with some potency and breadth in guinea pigs and rabbits, the DNA vaccinated macaques displayed less bNAb activity. It was concluded that a trivalent mix of non-modified gp140 genes from rationally selected clinical isolates was, in this study, the best option to induce high and broad NAb in the rabbit model, but this optimization does not directly translate into similar responses in cynomolgus macaques. PMID:26344115
Frueh, Florian S.; Körbel, Christina; Gassert, Laura; Müller, Andreas; Gousopoulos, Epameinondas; Lindenblatt, Nicole; Giovanoli, Pietro; Laschke, Matthias W.; Menger, Michael D.
2016-01-01
Secondary lymphedema is a common complication of cancer treatment characterized by chronic limb swelling with interstitial inflammation. The rodent hindlimb is a widely used model for the evaluation of novel lymphedema treatments. However, the assessment of limb volume in small animals is challenging. Recently, high-resolution three-dimensional (3D) imaging modalities have been introduced for rodent limb volumetry. In the present study we evaluated the validity of microcomputed tomography (μCT), magnetic resonance imaging (MRI) and ultrasound in comparison to conventional measuring techniques. For this purpose, acute lymphedema was induced in the mouse hindlimb by a modified popliteal lymphadenectomy. The 4-week course of this type of lymphedema was first assessed in 6 animals. In additional 12 animals, limb volumes were analyzed by μCT, 9.4 T MRI and 30 MHz ultrasound as well as by planimetry, circumferential length and paw thickness measurements. Interobserver correlation was high for all modalities, in particular for μCT analysis (r = 0.975, p < 0.001). Importantly, caliper-measured paw thickness correlated well with μCT (r = 0.861), MRI (r = 0.821) and ultrasound (r = 0.800). Because the assessment of paw thickness represents a time- and cost-effective approach, it may be ideally suited for the quantification of rodent hindlimb lymphedema. PMID:27698469
77 FR 76815 - Handling of Animals; Contingency Plans
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-31
... contingency plan system be implemented to accommodate small businesses. As a practical matter, one would... No. APHIS-2006-0159] RIN 0579-AC69 Handling of Animals; Contingency Plans AGENCY: Animal and Plant... regulations to add requirements for contingency planning and training of personnel by research facilities and...
Congenital spinal malformations in small animals.
Westworth, Diccon R; Sturges, Beverly K
2010-09-01
Congenital anomalies of the spine are common in small animals. The type of deformity, location, severity, time of onset of associated clinical signs, and progression of neurologic dysfunction varies widely. To promote clearer understanding, the authors present the various spinal malformations using modified human classification schemes and use current widely accepted definitions and terminology. The diagnostic approach, including utilization of advanced imaging, and surgical management is emphasized. Copyright 2010. Published by Elsevier Inc.
2016-10-01
2016 4. TITLE AND SUBTITLE Studying the Immunomodulatory Effects of Small Molecule Ras-Inhibitors in Animal Models of Rheumatoid Arthritis 5a...TERMS Ras GTPases; Rheumatoid Arthritis (RA); Farnesylthiosalicylic acid (FTS); T helper cells, disease-modifying antirheumatic drugs (DMARDs...anergy and to restore IL-2 production. Importantly, T cells from patients with Rheumatoid Arthritis (RA) display augmented activation of the Ras
2016-10-01
Studying the Immunomodulatory Effects of Small Molecule Ras-Inhibitors in Animal Models of Rheumatoid Arthritis 5a. CONTRACT NUMBER 5b. GRANT... Rheumatoid Arthritis (RA); Farnesylthiosalicylic acid (FTS); T helper cells, disease-modifying antirheumatic drugs (DMARDs); targeted synthetic DMARDs 16...active Ras was shown to reverse anergy and to restore IL-2 production. Importantly, T cells from patients with Rheumatoid Arthritis (RA) display
Transition by head-on collision: mechanically mediated manoeuvres in cockroaches and small robots.
Jayaram, Kaushik; Mongeau, Jean-Michel; Mohapatra, Anand; Birkmeyer, Paul; Fearing, Ronald S; Full, Robert J
2018-02-01
Exceptional performance is often considered to be elegant and free of 'errors' or missteps. During the most extreme escape behaviours, neural control can approach or exceed its operating limits in response time and bandwidth. Here we show that small, rapid running cockroaches with robust exoskeletons select head-on collisions with obstacles to maintain the fastest escape speeds possible to transition up a vertical wall. Instead of avoidance, animals use their passive body shape and compliance to negotiate challenging environments. Cockroaches running at over 1 m or 50 body lengths per second transition from the floor to a vertical wall within 75 ms by using their head like an automobile bumper, mechanically mediating the manoeuvre. Inspired by the animal's behaviour, we demonstrate a passive, high-speed, mechanically mediated vertical transitions with a small, palm-sized legged robot. By creating a collision model for animal and human materials, we suggest a size dependence favouring mechanical mediation below 1 kg that we term the 'Haldane limit'. Relying on the mechanical control offered by soft exoskeletons represents a paradigm shift for understanding the control of small animals and the next generation of running, climbing and flying robots where the use of the body can off-load the demand for rapid sensing and actuation. © 2018 The Authors.
Transition by head-on collision: mechanically mediated manoeuvres in cockroaches and small robots
Mongeau, Jean-Michel; Mohapatra, Anand; Birkmeyer, Paul; Fearing, Ronald S.; Full, Robert J.
2018-01-01
Exceptional performance is often considered to be elegant and free of ‘errors’ or missteps. During the most extreme escape behaviours, neural control can approach or exceed its operating limits in response time and bandwidth. Here we show that small, rapid running cockroaches with robust exoskeletons select head-on collisions with obstacles to maintain the fastest escape speeds possible to transition up a vertical wall. Instead of avoidance, animals use their passive body shape and compliance to negotiate challenging environments. Cockroaches running at over 1 m or 50 body lengths per second transition from the floor to a vertical wall within 75 ms by using their head like an automobile bumper, mechanically mediating the manoeuvre. Inspired by the animal's behaviour, we demonstrate a passive, high-speed, mechanically mediated vertical transitions with a small, palm-sized legged robot. By creating a collision model for animal and human materials, we suggest a size dependence favouring mechanical mediation below 1 kg that we term the ‘Haldane limit’. Relying on the mechanical control offered by soft exoskeletons represents a paradigm shift for understanding the control of small animals and the next generation of running, climbing and flying robots where the use of the body can off-load the demand for rapid sensing and actuation. PMID:29445036
Gamma-Ray Focusing Optics for Small Animal Imaging
NASA Technical Reports Server (NTRS)
Pivovaroff, M. J.; Barber, W. C.; Craig, W. W.; Hasegawa, B. H.; Ramsey, B. D.; Taylor, C.
2004-01-01
There is a well-established need for high-resolution radionuclide imaging techniques that provide non-invasive measurement of physiological function in small animals. We, therefore, have begun developing a small animal radionuclide imaging system using grazing incidence mirrors to focus low-energy gamma-rays emitted by I-125, and other radionuclides. Our initial prototype optic, fabricated from thermally-formed glass, demonstrated a resolution of 1500 microns, consistent with the performance predicted by detailed simulations. More recently, we have begun constructing mirrors using a replication technique that reduces low spatial frequency errors in the mirror surface, greatly improving the resolution. Each technique offers particular advantages: e.g., multilayer coatings are easily deposited on glass, while superior resolution is possible with replicated optics. Scaling the results from our prototype optics, which only have a few nested shells, to system where the lens has a full complement of several tens of nested shells, a sensitivity of approx. 1 cps/micro Ci is possible, with the exact number dependent on system magnification and radionuclide species. (Higher levels of efficiency can be obtained with multi-optic imaging systems.) The gamma-ray lens will achieve a resolution as good as 100 microns, independent of the final sensitivity. The combination of high spatial resolution and modest sensitivity will enable in vivo single photon emission imaging studies in small animals.
NASA Astrophysics Data System (ADS)
Zhang, Edward Z.; Laufer, Jan; Beard, Paul
2007-02-01
A 3D photoacoustic imaging instrument for characterising small animal models of human disease processes has been developed. The system comprises an OPO excitation source and a backward-mode planar ultrasound imaging head based upon a Fabry Perot polymer film sensing interferometer (FPI). The mirrors of the latter are transparent between 590 - 1200nm but highly reflective between 1500-1600nm. This enables nanosecond excitation laser pulses in the former wavelength range, where biological tissues are relatively transparent, to be transmitted through the sensor head into the tissue. The resulting photoacoustic signals arrive at the sensor where they modulate the optical thickness of the FPI and therefore its reflectivity. By scanning a CW focused interrogating laser beam at 1550nm across the surface of the sensor, the spatial-temporal distribution of the photoacoustic signals can therefore be mapped in 2D enabling a 3D photoacoustic image to be reconstructed. To demonstrate the application of the system to imaging small animals such as mice, 3D images of the vascular anatomy of the mouse brain and the microvasculature in the skin around the abdomen were obtained non invasively. It is considered that this system provides a practical alternative to photoacoustic scanners based upon piezoelectric detectors for high resolution non invasive small animal imaging.
CubeSat Mission- Near-Earth Asteroid Scout (animation only, no audio)
2016-09-21
The Near-Earth Asteroid Scout, or NEA Scout, is a robotic reconnaissance mission that will deploy a 6U CubeSat to fly by and return data from an asteroid representative of possible human destinations. Using a solar sail for its propulsion system, it will perform reconnaissance of an asteroid, take pictures and observe its position in space. Launching on NASA's Space Launch System rocket, the CubeSat deployment animation starts at the 1:25 timecode with the solar sail deployment animation beginning at the 2:54 timecode. The NEA Scout team is currently evaluating a range of targets, and is continually updating the candidate pool based on new discoveries and expected performance. NEA Scout is one of three payloads selected by NASA’s Human Exploration and Operations Mission Directorate. These small satellites were chosen to address Strategic Knowledge Gaps (SKGs) and help inform research strategies and prioritize technology development for future human and robotic exploration. It is being developed at NASA’s Marshall Space Flight Center in Huntsville, Alabama. Learn more by visiting http://www.nasa.gov/content/nea-scout
Effect of spaceflight on the extracellular matrix of skeletal muscle after a crush injury
NASA Technical Reports Server (NTRS)
Stauber, W. T.; Fritz, V. K.; Burkovskaia, T. E.; Il'ina-Kakueva, E. I.
1992-01-01
The organization and composition of the extracellular matrix were studied in the crush-injured gastrocnemius muscle of rats subjected to 0 G. After 14 days of flight on Cosmos 2044, the gastrocnemius muscle was removed and evaluated by histochemical and immunohistochemical techniques from the five injured flight rodents and various earth-based treatment groups. In general, the repair process was similar in all injured muscle samples with regard to the organization of the extracellular matrix and myofibers. Small and large myofibers were present within an expanded extracellular matrix, indicative of myogenesis and muscle regeneration. In the tail-suspended animals, a more complete repair was observed with nonenlarged area of nonmuscle cells or matrix material visible. In contrast, the muscle samples from the flight animals were less well organized and contained more macrophages and blood vessels in the repair region, indicative of a delayed repair process, but did not demonstrate any chronic inflammation. Myofiber repair did vary in muscles from the different groups, being slowest in the flight animals and most complete in the tail-suspended ones.
Detection of dietary DNA, protein, and glyphosate in meat, milk, and eggs.
Van Eenennaam, A L; Young, A E
2017-07-01
Products such as meat, milk, and eggs from animals that have consumed genetically engineered (GE) feed are not currently subject to mandatory GE labeling requirements. Some voluntary "non-genetically modified organism" labeling has been associated with such products, indicating that the animals were not fed GE crops, as there are no commercialized GE food animals. This review summarizes the available scientific literature on the detection of dietary DNA and protein in animal products and briefly discusses the implications of mandatory GE labeling for products from animals that have consumed GE feed. Because glyphosate is used on some GE crops, the available studies on glyphosate residues in animal products are also reviewed. In GE crops, recombinant DNA (rDNA) makes up a small percentage of the plant's total DNA. The final amount of DNA in food/feed depends on many factors including the variable number and density of cells in the edible parts, the DNA-containing matrix, environmental conditions, and the specific transgenic event. Processing treatments and animals' digestive systems degrade DNA into small fragments. Available reports conclude that endogenous DNA and rDNA are processed in exactly the same way in the gastrointestinal tract and that they account for a very small proportion of food intake by weight. Small pieces of high copy number endogenous plant genes have occasionally been detected in meat and milk. Similarly sized pieces of rDNA have also been identified in meat, primarily fish, although detection is inconsistent. Dietary rDNA fragments have not been detected in chicken or quail eggs or in fresh milk from cows or goats. Collectively, studies have failed to identify full-length endogenous or rDNA transcripts or recombinant proteins in meat, milk, or eggs. Similarly, because mammals do not bioaccumulate glyphosate and it is rapidly excreted, negligible levels of glyphosate in cattle, pig and poultry meat, milk, and eggs have been reported. Despite consumer concern about the presence of trace concentrations of glyphosate that might have been applied to feed crops and/or the presence of rDNA or recombinant proteins in meat, milk, and eggs, the available data do not provide evidence to suggest that products from animals that have consumed approved GE feed crops differ in any distinguishable way from those derived from animals fed conventional feed or that products from animals fed GE feedstuffs pose novel health risks.
Martin, John T; Milby, Andrew H; Ikuta, Kensuke; Poudel, Subash; Pfeifer, Christian G; Elliott, Dawn M; Smith, Harvey E; Mauck, Robert L
2015-10-01
Tissue engineering strategies have emerged in response to the growing prevalence of chronic musculoskeletal conditions, with many of these regenerative methods currently being evaluated in translational animal models. Engineered replacements for fibrous tissues such as the meniscus, annulus fibrosus, tendons, and ligaments are subjected to challenging physiologic loads, and are difficult to track in vivo using standard techniques. The diagnosis and treatment of musculoskeletal conditions depends heavily on radiographic assessment, and a number of currently available implants utilize radiopaque markers to facilitate in vivo imaging. In this study, we developed a nanofibrous scaffold in which individual fibers included radiopaque nanoparticles. Inclusion of radiopaque particles increased the tensile modulus of the scaffold and imparted radiation attenuation within the range of cortical bone. When scaffolds were seeded with bovine mesenchymal stem cells in vitro, there was no change in cell proliferation and no evidence of promiscuous conversion to an osteogenic phenotype. Scaffolds were implanted ex vivo in a model of a meniscal tear in a bovine joint and in vivo in a model of total disc replacement in the rat coccygeal spine (tail), and were visualized via fluoroscopy and microcomputed tomography. In the disc replacement model, histological analysis at 4 weeks showed that the scaffold was biocompatible and supported the deposition of fibrous tissue in vivo. Nanofibrous scaffolds that include radiopaque nanoparticles provide a biocompatible template with sufficient radiopacity for in vivo visualization in both small and large animal models. This radiopacity may facilitate image-guided implantation and non-invasive long-term evaluation of scaffold location and performance. The healing capacity of fibrous musculoskeletal tissues is limited, and injury or degeneration of these tissues compromises the standard of living of millions in the US. Tissue engineering repair strategies for the intervertebral disc, meniscus, tendon and ligament have progressed from in vitro to in vivo evaluation using a variety of animal models, and the clinical application of these technologies is imminent. The composition of most scaffold materials however does not allow for visualization by methods available to clinicians (e.g., radiography), and thus it is not possible to assess their performance in situ. In this work, we describe a radiopaque nanofibrous scaffold that can be visualized radiographically in both small and large animal models and serve as a framework for the development of an engineered fibrous tissue. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Tabassum, Syeda; Zhao, Yanyu; Istfan, Raeef; Wu, Junjie; Waxman, David J; Roblyer, Darren
2016-10-01
Determination of chemotherapy efficacy early during treatment would provide more opportunities for physicians to alter and adapt treatment plans. Diffuse optical technologies may be ideally suited to track early biological events following chemotherapy administration due to low cost and high information content. We evaluated the use of spatial frequency domain imaging (SFDI) to characterize a small animal tumor model in order to move towards the goal of endogenous optical monitoring of cancer therapy in a controlled preclinical setting. The effects of key measurement parameters including the choice of imaging spatial frequency and the repeatability of measurements were evaluated. The precision of SFDI optical property extractions over repeat mouse measurements was determined to be within 3.52% for move and replace experiments. Baseline optical properties and chromophore values as well as intratumor heterogeneity were evaluated over 25 tumors. Additionally, tumor growth and chemotherapy response were monitored over a 45 day longitudinal study in a small number of mice to demonstrate the ability of SFDI to track treatment effects. Optical scattering and oxygen saturation increased as much as 70% and 25% respectively in treated tumors, suggesting SFDI may be useful for preclinical tracking of cancer therapies.
Zhu, Shaomei; Liu, Bochao; Xu, Yuxia; Sun, Yachun; Wang, Yilin; Wang, Yuanzhan; Shuai, Lifang; Chen, Zixuan; Allain, Jean-Pierre
2016-01-01
ABSTRACT A lack of immunocompetent-small-primate models has been an obstacle for developing hepatitis C virus (HCV) vaccines and affordable antiviral drugs. In this study, HCV/GB virus B (GBV-B) chimeric virus carrying the major nonstructural proteins NS2 to NS4A (HCV NS2 to -4A chimera) was produced and used to infect common marmosets, since HCV NS2 to NS4A proteins are critical proteases and major antigens. Seven marmosets were inoculated intrahepatically with HCV NS2 to -4A chimera RNA for primary infection or intravenously injected with chimera-containing serum for passage infection. Three animals used as controls were injected with phosphate-buffered saline (PBS) or GBV-B, respectively. Six of seven HCV NS2 to -4A chimera-infected marmosets exhibited consistent viremia and one showed transient viremia during the course of follow-up detection. All six infected animals with persistent circulating viremia presented characteristics typical of viral hepatitis, including viral RNA and proteins in hepatocytes and histopathological changes in liver tissue. Viremia was consistently detected for 5 to 54 weeks of follow-up. FK506 immunosuppression facilitated the establishment of persistent chimera infection in marmosets. An animal with chimera infection spontaneously cleared the virus in blood 7 weeks following the first inoculation, but viral-RNA persistence, low-level viral protein, and mild necroinflammation remained in liver tissue. The specific antibody and T-cell response to HCV NS3 in this viremia-resolved marmoset was boosted by rechallenging, but no viremia was detected during 57 weeks of follow-up. The chimera-infected marmosets described can be used as a suitable small-primate animal model for studying novel antiviral drugs and T-cell-based vaccines against HCV infection. IMPORTANCE HCV infection causes approximately 70% of chronic hepatitis and is frequently associated with primary liver cancer globally. Chimpanzees have been used as a reliable primate model for HCV infection, but ethical considerations have restricted their utility in biomedical research. GB virus B (GBV-B) is a flavivirus related to HCV. It can infect common marmosets, a New World small primate, and induces viral hepatitis similar to HCV infection in humans. To minimize differences between GBV-B and HCV, we generated HCV NS2 to -4A/GBV-B chimeric viruses and established a chimera-infected marmoset model. HCV NS2 to -4A chimera-infected marmosets provide a small-animal model for evaluating novel antiviral drugs targeting HCV NS3-NS4A protease and T-cell-based HCV vaccines. PMID:27384651
Zhu, Shaomei; Li, Tingting; Liu, Bochao; Xu, Yuxia; Sun, Yachun; Wang, Yilin; Wang, Yuanzhan; Shuai, Lifang; Chen, Zixuan; Allain, Jean-Pierre; Li, Chengyao
2016-09-15
A lack of immunocompetent-small-primate models has been an obstacle for developing hepatitis C virus (HCV) vaccines and affordable antiviral drugs. In this study, HCV/GB virus B (GBV-B) chimeric virus carrying the major nonstructural proteins NS2 to NS4A (HCV NS2 to -4A chimera) was produced and used to infect common marmosets, since HCV NS2 to NS4A proteins are critical proteases and major antigens. Seven marmosets were inoculated intrahepatically with HCV NS2 to -4A chimera RNA for primary infection or intravenously injected with chimera-containing serum for passage infection. Three animals used as controls were injected with phosphate-buffered saline (PBS) or GBV-B, respectively. Six of seven HCV NS2 to -4A chimera-infected marmosets exhibited consistent viremia and one showed transient viremia during the course of follow-up detection. All six infected animals with persistent circulating viremia presented characteristics typical of viral hepatitis, including viral RNA and proteins in hepatocytes and histopathological changes in liver tissue. Viremia was consistently detected for 5 to 54 weeks of follow-up. FK506 immunosuppression facilitated the establishment of persistent chimera infection in marmosets. An animal with chimera infection spontaneously cleared the virus in blood 7 weeks following the first inoculation, but viral-RNA persistence, low-level viral protein, and mild necroinflammation remained in liver tissue. The specific antibody and T-cell response to HCV NS3 in this viremia-resolved marmoset was boosted by rechallenging, but no viremia was detected during 57 weeks of follow-up. The chimera-infected marmosets described can be used as a suitable small-primate animal model for studying novel antiviral drugs and T-cell-based vaccines against HCV infection. HCV infection causes approximately 70% of chronic hepatitis and is frequently associated with primary liver cancer globally. Chimpanzees have been used as a reliable primate model for HCV infection, but ethical considerations have restricted their utility in biomedical research. GB virus B (GBV-B) is a flavivirus related to HCV. It can infect common marmosets, a New World small primate, and induces viral hepatitis similar to HCV infection in humans. To minimize differences between GBV-B and HCV, we generated HCV NS2 to -4A/GBV-B chimeric viruses and established a chimera-infected marmoset model. HCV NS2 to -4A chimera-infected marmosets provide a small-animal model for evaluating novel antiviral drugs targeting HCV NS3-NS4A protease and T-cell-based HCV vaccines. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Semiautomated analysis of small-animal PET data.
Kesner, Adam L; Dahlbom, Magnus; Huang, Sung-Cheng; Hsueh, Wei-Ann; Pio, Betty S; Czernin, Johannes; Kreissl, Michael; Wu, Hsiao-Ming; Silverman, Daniel H S
2006-07-01
The objective of the work reported here was to develop and test automated methods to calculate biodistribution of PET tracers using small-animal PET images. After developing software that uses visually distinguishable organs and other landmarks on a scan to semiautomatically coregister a digital mouse phantom with a small-animal PET scan, we elastically transformed the phantom to conform to those landmarks in 9 simulated scans and in 18 actual PET scans acquired of 9 mice. Tracer concentrations were automatically calculated in 22 regions of interest (ROIs) reflecting the whole body and 21 individual organs. To assess the accuracy of this approach, we compared the software-measured activities in the ROIs of simulated PET scans with the known activities, and we compared the software-measured activities in the ROIs of real PET scans both with manually established ROI activities in original scan data and with actual radioactivity content in immediately harvested tissues of imaged animals. PET/atlas coregistrations were successfully generated with minimal end-user input, allowing rapid quantification of 22 separate tissue ROIs. The simulated scan analysis found the method to be robust with respect to the overall size and shape of individual animal scans, with average activity values for all organs tested falling within the range of 98% +/- 3% of the organ activity measured in the unstretched phantom scan. Standardized uptake values (SUVs) measured from actual PET scans using this semiautomated method correlated reasonably well with radioactivity content measured in harvested organs (median r = 0.94) and compared favorably with conventional SUV correlations with harvested organ data (median r = 0.825). A semiautomated analytic approach involving coregistration of scan-derived images with atlas-type images can be used in small-animal whole-body radiotracer studies to estimate radioactivity concentrations in organs. This approach is rapid and less labor intensive than are traditional methods, without diminishing overall accuracy. Such techniques have the possibility of saving time, effort, and the number of animals needed for such assessments.
Real-Time Microfluidic Blood-Counting System for PET and SPECT Preclinical Pharmacokinetic Studies.
Convert, Laurence; Lebel, Réjean; Gascon, Suzanne; Fontaine, Réjean; Pratte, Jean-François; Charette, Paul; Aimez, Vincent; Lecomte, Roger
2016-09-01
Small-animal nuclear imaging modalities have become essential tools in the development process of new drugs, diagnostic procedures, and therapies. Quantification of metabolic or physiologic parameters is based on pharmacokinetic modeling of radiotracer biodistribution, which requires the blood input function in addition to tissue images. Such measurements are challenging in small animals because of their small blood volume. In this work, we propose a microfluidic counting system to monitor rodent blood radioactivity in real time, with high efficiency and small detection volume (∼1 μL). A microfluidic channel is built directly above unpackaged p-i-n photodiodes to detect β-particles with maximum efficiency. The device is embedded in a compact system comprising dedicated electronics, shielding, and pumping unit controlled by custom firmware to enable measurements next to small-animal scanners. Data corrections required to use the input function in pharmacokinetic models were established using calibrated solutions of the most common PET and SPECT radiotracers. Sensitivity, dead time, propagation delay, dispersion, background sensitivity, and the effect of sample temperature were characterized. The system was tested for pharmacokinetic studies in mice by quantifying myocardial perfusion and oxygen consumption with (11)C-acetate (PET) and by measuring the arterial input function using (99m)TcO4 (-) (SPECT). Sensitivity for PET isotopes reached 20%-47%, a 2- to 10-fold improvement relative to conventional catheter-based geometries. Furthermore, the system detected (99m)Tc-based SPECT tracers with an efficiency of 4%, an outcome not possible through a catheter. Correction for dead time was found to be unnecessary for small-animal experiments, whereas propagation delay and dispersion within the microfluidic channel were accurately corrected. Background activity and sample temperature were shown to have no influence on measurements. Finally, the system was successfully used in animal studies. A fully operational microfluidic blood-counting system for preclinical pharmacokinetic studies was developed. Microfluidics enabled reliable and high-efficiency measurement of the blood concentration of most common PET and SPECT radiotracers with high temporal resolution in small blood volume. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Oral vaccination of captive small Indian mongoose (Herpestes auropunctatus) against rabies.
Vos, Ad; Kretzschmar, Antje; Ortmann, Steffen; Lojkic, Ivana; Habla, Christiane; Müller, Thomas; Kaiser, Christian; Hundt, Boris; Schuster, Peter
2013-10-01
The small Indian mongoose (Herpestes auropunctatus), a rabies reservoir species on several Islands in the Caribbean, was successfully immunized against rabies for the first time by offering animals a vaccine bait specifically designed for this small carnivore. The bait contained on average 0.6 mL of the genetically modified replication-competent rabies virus construct SPBN GASGAS (10(8.5) focus-forming units/mL). Three of four mongooses offered a bait developed an immune response above 0.5 IU/mL, but the response was less pronounced than in two animals offered the vaccine by direct oral instillation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Birkner, R.; Meyer, R.; Trautmann, J.
1957-01-01
ABS>The effect of small doses of whole-body x radiation on the septicemia caused by Klebsiella pneumoniac Friedlander in white mice depends on the moment of the irradiation, the dose, the temporal dose distribution, the age and the sex of the animals, as well as on the quantity of germs applied. Animals die more rapidly if irradiations have been applied previous to the infection, while irradiations after infections lead to longer life. (auth)
Leptospirosis in sheep and goats under tropical conditions.
Martins, Gabriel; Lilenbaum, Walter
2014-01-01
Inadequate management practices and poor reproductive performance have been reported as fundamental factors on reducing the levels of productivity in livestock. Different pathogens have been reported in small ruminants' herds/flocks with reproductive failures. The aim of the present study was to review aspects of leptospirosis in small ruminants, mainly its impact on reproduction and consequently on productivity of the herds/flocks under tropical conditions. Leptospiral infection in goats and sheep is common in several countries, and those species can also act as carriers of leptospires. Severe disease is often associated to young animals and is frequently associated to incidental serovars. In contrast, subclinical infection is mainly characterized by reproductive problems, such as infertility, abortion, occurrence of stillbirths, and weak lambs/goat kids. Moreover, laboratorial tests are essential to achieve an accurate diagnosis of the infection. Microscopic agglutination test is the most common indirect test of leptospirosis, being used worldwide. In small ruminants, PCR consists on a recommendable method for diagnosing animals that carry leptospires. Control of leptospirosis in small ruminants involves measures such as the identification and treatment of the carriers and other sources of infection, quarantine in acquired animals, and systematic immunization with commercial vaccines containing the circulating serovars in the herd/flock. Productivity of small ruminant breeding can dramatically increase with adequate sanitary conditions and control of leptospirosis. Immunization of all the animals combined to the treatment of carriers may successfully control the infection and importantly reduce the economic reproductive hazards that are observed under tropical conditions.
Sukhotnik, Igor; Mogilner, Jorge G; Lerner, Aaron; Coran, Arnold G; Lurie, Michael; Miselevich, Iness; Shiloni, Eitan
2005-06-01
The nitric oxide precursor L-arginine (ARG) has been shown to influence intestinal structure and absorptive function. It is also well known that the route of administration modulates the effects of ARG. The present study evaluated the effects of parenteral ARG on structural intestinal adaptation, cell proliferation, and apoptosis in a rat model of short bowel syndrome (SBS). Male Sprague-Dawley rats were divided into three experimental groups: Sham rats underwent bowel transection and reanastomosis, SBS rats underwent a 75% small bowel resection, and SBS-ARG rats underwent a 75% small bowel resection and were treated with ARG given subcutaneously at a dose of 300 mug/kg, once daily, from days 3 to 14. Parameters of intestinal adaptation, enterocyte proliferation, and enterocyte apoptosis were determined on day 15 following operation. The SBS rats demonstrated a significant increase in jejunal and ileal bowel and mucosal weight, villus height and crypt depth, and cell proliferation index compared with the sham group. The SBS-ARG animals demonstrated lower ileal bowel and mucosal weights, jejunal mucosal DNA and ileal mucosal protein, and jejunal and ileal villus height and crypt depth compared with SBS animals. The SBS-ARG rats also had a lower cell proliferation index in both jejunum and ileum and a greater enterocyte apoptotic index in ileum compared with the SBS-untreated group. In conclusion, in a rat model of SBS, parenteral arginine inhibits structural intestinal adaptation. Decreased cell proliferation and increased apoptosis are the main mechanisms responsible for decreased cell mass.
Pain assessment in animal models of osteoarthritis.
Piel, Margaret J; Kroin, Jeffrey S; van Wijnen, Andre J; Kc, Ranjan; Im, Hee-Jeong
2014-03-10
Assessment of pain in animal models of osteoarthritis is integral to interpretation of a model's utility in representing the clinical condition, and enabling accurate translational medicine. Here we describe behavioral pain assessments available for small and large experimental osteoarthritic pain animal models. Copyright © 2013 Elsevier B.V. All rights reserved.
9 CFR 2.1 - Requirements and application.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Section 2.1 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF... required to obtain a license; (iii) Any person who maintains a total of three (3) or fewer breeding female... that collectively maintains a total of more than three breeding female dogs, cats, and/or small exotic...
9 CFR 2.1 - Requirements and application.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Section 2.1 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF... required to obtain a license; (iii) Any person who maintains a total of three (3) or fewer breeding female... that collectively maintains a total of more than three breeding female dogs, cats, and/or small exotic...
9 CFR 2.1 - Requirements and application.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Section 2.1 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF... required to obtain a license; (iii) Any person who maintains a total of three (3) or fewer breeding female... that collectively maintains a total of more than three breeding female dogs, cats, and/or small exotic...
9 CFR 2.1 - Requirements and application.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Section 2.1 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE, DEPARTMENT OF... required to obtain a license; (iii) Any person who maintains a total of three (3) or fewer breeding female... that collectively maintains a total of more than three breeding female dogs, cats, and/or small exotic...
AMMONIA ABATEMENT SYSTEM FOR WHOLE-BODY SMALL ANIMAL INHALATION EXPOSURES TO ACID MODELS
Conducting whole-body acid aerosol inhalation exposures of laboratory animals is complicated by ammonia arising from the excrement of the test animals which is sufficient to completely neutralize much of the acid aerosol. he neutralization of acid by ammonia con only be controlle...
Manzano-Szalai, Krisztina; Pali-Schöll, Isabella; Krishnamurthy, Durga; Stremnitzer, Caroline; Flaschberger, Ingo; Jensen-Jarolim, Erika
2016-01-01
In highly sensitized patients, the encounter with a specific allergen from food, insect stings or medications may rapidly induce systemic anaphylaxis with potentially lethal symptoms. Countless animal models of anaphylaxis, most often in BALB/c mice, were established to understand the pathophysiology and to prove the safety of different treatments. The most common symptoms during anaphylactic shock are drop of body temperature and reduced physical activity. To refine, improve and objectify the currently applied manual monitoring methods, we developed an imaging method for the automated, non-invasive measurement of the whole-body surface temperature and, at the same time, of the horizontal and vertical movement activity of small animals. We tested the anaphylaxis imaging in three in vivo allergy mouse models for i) milk allergy, ii) peanut allergy and iii) egg allergy. These proof-of-principle experiments suggest that the imaging technology represents a reliable non-invasive method for the objective monitoring of small animals during anaphylaxis over time. We propose that the method will be useful for monitoring diseases associated with both, changes in body temperature and in physical behaviour. PMID:26963393
The hydrodynamic principle for the caudal fin shape of small aquatic animals
NASA Astrophysics Data System (ADS)
Lee, Jeongsu; Park, Yong-Jai; Cho, Kyu-Jin; Kim, Ho-Young
2014-11-01
The shape of caudal fins of small aquatic animals is completely different from that of large cruising animals like dolphin and tuna which have high aspect-ratio lunate tail. To unveil the physical principle behind natural selection of caudal fins of small aquatic animals, here we investigate the hydrodynamics of an angularly reciprocating plate as a model for the caudal fin oscillation. We find that the thrust production of a reciprocating plate at high Strouhal numbers is dominated by generation of two distinct vortical structures associated with the acceleration and deceleration of the plate regardless of their shape. Based on our observations, we construct a scaling law to predict the thrust of the flapping plate, which agrees well with the experimental data. We then seek the optimal aspect ratio to maximize thrust and efficiency of a flapping plate for fixed flapping frequency and amplitude. Thrust is maximized for the aspect ratio of approximately 0.7. We also theoretically explain the power law behaviors of the thrust and efficiency as a function of the aspect ratio.
High proportion of cactus species threatened with extinction.
Goettsch, Bárbara; Hilton-Taylor, Craig; Cruz-Piñón, Gabriela; Duffy, James P; Frances, Anne; Hernández, Héctor M; Inger, Richard; Pollock, Caroline; Schipper, Jan; Superina, Mariella; Taylor, Nigel P; Tognelli, Marcelo; Abba, Agustín M; Arias, Salvador; Arreola-Nava, Hilda J; Baker, Marc A; Bárcenas, Rolando T; Barrios, Duniel; Braun, Pierre; Butterworth, Charles A; Búrquez, Alberto; Caceres, Fátima; Chazaro-Basañez, Miguel; Corral-Díaz, Rafael; Del Valle Perea, Mario; Demaio, Pablo H; Duarte de Barros, Williams A; Durán, Rafael; Yancas, Luis Faúndez; Felger, Richard S; Fitz-Maurice, Betty; Fitz-Maurice, Walter A; Gann, George; Gómez-Hinostrosa, Carlos; Gonzales-Torres, Luis R; Patrick Griffith, M; Guerrero, Pablo C; Hammel, Barry; Heil, Kenneth D; Hernández-Oria, José Guadalupe; Hoffmann, Michael; Ishihara, Mario Ishiki; Kiesling, Roberto; Larocca, João; León-de la Luz, José Luis; Loaiza S, Christian R; Lowry, Martin; Machado, Marlon C; Majure, Lucas C; Ávalos, José Guadalupe Martínez; Martorell, Carlos; Maschinski, Joyce; Méndez, Eduardo; Mittermeier, Russell A; Nassar, Jafet M; Negrón-Ortiz, Vivian; Oakley, Luis J; Ortega-Baes, Pablo; Ferreira, Ana Beatriz Pin; Pinkava, Donald J; Porter, J Mark; Puente-Martinez, Raul; Gamarra, José Roque; Pérez, Patricio Saldivia; Martínez, Emiliano Sánchez; Smith, Martin; Manuel Sotomayor M Del C, J; Stuart, Simon N; Muñoz, José Luis Tapia; Terrazas, Teresa; Terry, Martin; Trevisson, Marcelo; Valverde, Teresa; Van Devender, Thomas R; Véliz-Pérez, Mario Esteban; Walter, Helmut E; Wyatt, Sarah A; Zappi, Daniela; Alejandro Zavala-Hurtado, J; Gaston, Kevin J
2015-10-05
A high proportion of plant species is predicted to be threatened with extinction in the near future. However, the threat status of only a small number has been evaluated compared with key animal groups, rendering the magnitude and nature of the risks plants face unclear. Here we report the results of a global species assessment for the largest plant taxon evaluated to date under the International Union for Conservation of Nature (IUCN) Red List Categories and Criteria, the iconic Cactaceae (cacti). We show that cacti are among the most threatened taxonomic groups assessed to date, with 31% of the 1,478 evaluated species threatened, demonstrating the high anthropogenic pressures on biodiversity in arid lands. The distribution of threatened species and the predominant threatening processes and drivers are different to those described for other taxa. The most significant threat processes comprise land conversion to agriculture and aquaculture, collection as biological resources, and residential and commercial development. The dominant drivers of extinction risk are the unscrupulous collection of live plants and seeds for horticultural trade and private ornamental collections, smallholder livestock ranching and smallholder annual agriculture. Our findings demonstrate that global species assessments are readily achievable for major groups of plants with relatively moderate resources, and highlight different conservation priorities and actions to those derived from species assessments of key animal groups.
In vitro transcriptomic prediction of hepatotoxicity for early drug discovery
Cheng, Feng; Theodorescu, Dan; Schulman, Ira G.; Lee, Jae K.
2012-01-01
Liver toxicity (hepatotoxicity) is a critical issue in drug discovery and development. Standard preclinical evaluation of drug hepatotoxicity is generally performed using in vivo animal systems. However, only a small number of preselected compounds can be examined in vivo due to high experimental costs. A more efficient yet accurate screening technique which can identify potentially hepatotoxic compounds in the early stages of drug development would thus be valuable. Here, we develop and apply a novel genomic prediction technique for screening hepatotoxic compounds based on in vitro human liver cell tests. Using a training set of in vivo rodent experiments for drug hepatotoxicity evaluation, we discovered common biomarkers of drug-induced liver toxicity among six heterogeneous compounds. This gene set was further triaged to a subset of 32 genes that can be used as a multi-gene expression signature to predict hepatotoxicity. This multi-gene predictor was independently validated and showed consistently high prediction performance on five test sets of in vitro human liver cell and in vivo animal toxicity experiments. The predictor also demonstrated utility in evaluating different degrees of toxicity in response to drug concentrations which may be useful not only for discerning a compound’s general hepatotoxicity but also for determining its toxic concentration. PMID:21884709
Suspension-Feeding Vertebrates.
ERIC Educational Resources Information Center
Sanderson, S. Laurie; Wassersug, Richard
1990-01-01
Described are animals that can filter their food out of the water. Various structures modified to strain plankton and small animals from water are detailed. The adaptive significance of these structures is discussed. (CW)
Economic performance of small ruminants in mixed-farming systems of Southern Ethiopia.
Legesse, Getahun; Siegmund-Schultze, Marianna; Abebe, Girma; Zárate, Anne Valle
2010-10-01
This study evaluates the household income contribution and the profitability of traditional small ruminant enterprises in two mixed-farming systems of southern Ethiopia (viz. Adilo and Kofele). Small ruminant production is an integral part of mixed systems in the Ethiopian highlands. The assessment of the current economic performance of small ruminants indicates production-related opportunities and constraints and provides baseline data against which the success of future interventions can be measured. Detailed information on economic parameters was gathered through a 1-year period of flock and household monitoring (155 households) between September 2005 and August 2006. Structured surveys were conducted with the participating households to elicit information on income-expense details of small ruminant and other agricultural enterprises. Small ruminants contributed considerably to cash income and to a limited extent to human nutrition especially when other sources were in short supply. The annual profit per animal ranged from 20 to 37 Ethiopian Birr. The return to capital was 17% in Kofele and 29% in Adilo, with both values vastly exceeding the national interest rate. The sale of small ruminants contributed to 39% and 23% of total farm cash income among small ruminant keepers in Adilo and Kofele, respectively. Sale prices are highest before holidays. Researches should target at how to use available feed resources in a timely and cost-effective fashion to make use of the seasonal market opportunities.
The Mini Space Farm—A Food Regenerative System in the Long-term Manned Space Mission.
NASA Astrophysics Data System (ADS)
Zhang, Mao
In this invention we propose rearing six types of small animals which are mainly insects, all the biological wastes (bio-waste) in the space human life environment, including the human and animal feces, inedible parts of the plants and animals, food bits and other bio-wastes,can be feedstuff for rearing these six small animals, each one can recycle and digest the specific wastes to be their nourishing biomass. The biomass of these six animals, combine with the inedible parts of the space plants, will further be used as feedstuff for feeding edible animals of poultry, aquatics, amphibians, even the livestock. The meat, egg and milk from these edible animals are taken as human's animal food. Here we name these animals are as Edible Animal (EA), these six small animals are as Recycling Animals (RA). The water and nutrition left in the residues after rearing the RA can be recycled again by other RA or used to fertilize the space plants. The appropriate space plants include both terrestrial and aquatic species, such as vegetable,grain,feeding plant,edible algae and germs,also be cultivated as vegetarian food which have already successfully developed by NASA and other countries. These RA have strong reproduction ability, short life cycle, rich of nutrition, and can be easily reared in high densities with high efficiency in microgravity. Like the RA, the EA and space plants, they can be continuously reared in cages,boxes and water tanks as the solid manner, their optimal growth temperature and the humidity are same with RA, so they can be fed in the same cabin. Rearing RA, EA and plants together can provide a self-sustaining food system with minimum volume, weight, energy, labor and cost, which is the basis for realizing mini space farm in long term manned space missions. In this way, two kinds of mini space farm models have been designed: A cabin model to be used on ISS and flight craft functioning within a microgravity environment, and a greenhouse model to be used on planetary habitats with low gravity.
Interactions between fleshy fruits and frugivores in a tropical seasonal forest in Thailand.
Kitamura, Shumpei; Yumoto, Takakazu; Poonswad, Pilai; Chuailua, Phitaya; Plongmai, Kamol; Maruhashi, Tamaki; Noma, Naohiko
2002-12-01
Large frugivores are considered to be important seed dispersers for many tropical plant species. Their roles as seed dispersers are not well known in Southeast Asia, where degraded landscapes typically lack these animals. Interactions between 259 (65 families) vertebrate-dispersed fruits and frugivorous animals (including 7 species of bulbul, 1 species of pigeon, 4 species of hornbill, 2 species of squirrel, 3 species of civet, 2 species of gibbon, 1 species of macaque, 2 species of bear, 2 species of deer, and 1 species of elephant) were studied for 3 years in a tropical seasonal forest in Khao Yai National Park, Thailand. The purpose was to examine the dietary overlaps among the large frugivores and the characteristics of fruits they consumed. Most fruit species are eaten by various kinds of frugivores; no close relationship between a particular fruit and a frugivore was found. The number of frugivore groups that served a given plant species was negatively correlated with seed size. Additionally, the fruit/seed diameters consumed by bulbuls were significantly smaller than consumed by the other nine groups. These trends of fruit characteristics were consistent with those observed elsewhere in Southeast Asia: small fruits and large, soft fruits with many small seeds are consumed by a wide spectrum of frugivores while larger fruits with a single large seed are consumed by relatively few potential dispersers. Importantly, these large, single-seed fruits are not consumed by the small frugivores that thrive in small forest fragments and degraded areas in Southeast Asia. To insure the natural seed dispersal process in the forest, an evaluation of all frugivore groups in the forest is urgently needed in Southeast Asia.
Yuan, Ming-Long; Dou, Wei; Barker, Stephen C.; Wang, Jin-Jun
2012-01-01
Booklice (order Psocoptera) in the genus Liposcelis are major pests to stored grains worldwide and are closely related to parasitic lice (order Phthiraptera). We sequenced the mitochondrial (mt) genome of Liposcelis bostrychophila and found that the typical single mt chromosome of bilateral animals has fragmented into and been replaced by two medium-sized chromosomes in this booklouse; each of these chromosomes has about half of the genes of the typical mt chromosome of bilateral animals. These mt chromosomes are 8,530 bp (mt chromosome I) and 7,933 bp (mt chromosome II) in size. Intriguingly, mt chromosome I is twice as abundant as chromosome II. It appears that the selection pressure for compact mt genomes in bilateral animals favors small mt chromosomes when small mt chromosomes co-exist with the typical large mt chromosomes. Thus, small mt chromosomes may have selective advantages over large mt chromosomes in bilateral animals. Phylogenetic analyses of mt genome sequences of Psocodea (i.e. Psocoptera plus Phthiraptera) indicate that: 1) the order Psocoptera (booklice and barklice) is paraphyletic; and 2) the order Phthiraptera (the parasitic lice) is monophyletic. Within parasitic lice, however, the suborder Ischnocera is paraphyletic; this differs from the traditional view that each suborder of parasitic lice is monophyletic. PMID:22479490
Saito, Mika; Nakata, Katsushi; Nishijima, Taku; Yamashita, Katsuhiro; Saito, Anna; Ogura, Go
2009-06-01
A project to eradicate invasive small Asian mongooses (Herpestes javanicus) is underway to conserve the unique ecosystem of Okinawa Island, Japan. In the present study, we tried to elucidate whether the mongoose is a host of Japanese encephalitis virus (JEV) and to evaluate the reliability of surveillance of Japanese encephalitis (JE) using this species. Culex tritaeniorhynchus, the main vector mosquito of JEV, feeds on the mongoose. Eighty-five (35.4%) of 240 wild small Asian mongooses captured between 2001 and 2005 had neutralizing antibodies against more than one of four JEV strains. Prevalence rates of JEV antibodies tended to increase with body weight and length of the animals. One of three sentinel mongooses showed a temporal change in antibody titer. These results indicate that the small Asian mongooses on Okinawa Island are sensitive to JEV. From the antibody titers and the locations of capture, the JEV active area was clarified. We propose that surveillance of JE using mongooses captured under the eradication program is reliable.
Assessment of Spectral Doppler in Preclinical Ultrasound Using a Small-Size Rotating Phantom
Yang, Xin; Sun, Chao; Anderson, Tom; Moran, Carmel M.; Hadoke, Patrick W.F.; Gray, Gillian A.; Hoskins, Peter R.
2013-01-01
Preclinical ultrasound scanners are used to measure blood flow in small animals, but the potential errors in blood velocity measurements have not been quantified. This investigation rectifies this omission through the design and use of phantoms and evaluation of measurement errors for a preclinical ultrasound system (Vevo 770, Visualsonics, Toronto, ON, Canada). A ray model of geometric spectral broadening was used to predict velocity errors. A small-scale rotating phantom, made from tissue-mimicking material, was developed. True and Doppler-measured maximum velocities of the moving targets were compared over a range of angles from 10° to 80°. Results indicate that the maximum velocity was overestimated by up to 158% by spectral Doppler. There was good agreement (<10%) between theoretical velocity errors and measured errors for beam-target angles of 50°–80°. However, for angles of 10°–40°, the agreement was not as good (>50%). The phantom is capable of validating the performance of blood velocity measurement in preclinical ultrasound. PMID:23711503
Evaluation of harmonic direction-finding systems for detecting locomotor activity
Boyarski, V.L.; Rodda, G.H.; Savidge, J.A.
2007-01-01
We conducted a physical simulation experiment to test the efficacy of harmonic direction finding for remotely detecting locomotor activity in animals. The ability to remotely detect movement helps to avoid disturbing natural movement behavior. Remote detection implies that the observer can sense only a change in signal bearing. In our simulated movements, small changes in bearing (<5.7??) were routinely undetectable. Detectability improved progressively with the size of the simulated animal movement. The average (??SD) of reflector tag movements correctly detected for 5 observers was 93.9 ?? 12.8% when the tag was moved ???11.5??; most observers correctly detected tag movements ???20.1??. Given our data, one can assess whether the technique will be effective for detecting movements at an observation distance appropriate for the study organism. We recommend that both habitat and behavior of the organism be taken into consideration when contemplating use of this technique for detecting locomotion.
Toribo, S.G.; Gray, B.R.; Liang, S.
2011-01-01
The N-mixture model proposed by Royle in 2004 may be used to approximate the abundance and detection probability of animal species in a given region. In 2006, Royle and Dorazio discussed the advantages of using a Bayesian approach in modelling animal abundance and occurrence using a hierarchical N-mixture model. N-mixture models assume replication on sampling sites, an assumption that may be violated when the site is not closed to changes in abundance during the survey period or when nominal replicates are defined spatially. In this paper, we studied the robustness of a Bayesian approach to fitting the N-mixture model for pseudo-replicated count data. Our simulation results showed that the Bayesian estimates for abundance and detection probability are slightly biased when the actual detection probability is small and are sensitive to the presence of extra variability within local sites.
[Helminths of carnivores relevant to veterinary practice].
Hasslinger, M A
1986-01-01
Especially in an urban environment man and carnivores live closely together, whereby one has to pay attention not only to animal parasites, but also to human pathogenic connections regarding these parasites. Because of the infection risk the animal owner has to be competently informed by his veterinarian. While some cestodes make great demands on hygiene, with others the cycle can be interrupted by consequent diet restrictions. Of all nematodes the stomach worm of the cat is of greater importance as it is easily overlooked because of its small size, is difficult to diagnose and is occurring in our regions with an infestation rate of about 40%. "Larva migrans visceralis" and "Larva migrans cutanea" caused by ascaride and hookworm larvae are important in human medicine and demand therapeutic measures. The contamination of parks, playgrounds and beaches with these parasites caused by carnivores requires a critical evaluation of the human pathogen interests.
ERIC Educational Resources Information Center
Kimbrough, T. Daniel; Llewellyn, Gerald C.
1973-01-01
Describes a surgical technique for performing pinealectomics, applicable to classroom and laboratory studies, by using a head-holding device for small animals and a flat dissecting tray outfitted with holding straps for larger animals. (CC)
The modified hole board--measuring behavior, cognition and social interaction in mice and rats.
Labots, Maaike; Van Lith, Hein A; Ohl, Frauke; Arndt, Saskia S
2015-04-08
This protocol describes the modified hole board (mHB), which combines features from a traditional hole board and open field and is designed to measure multiple dimensions of unconditioned behavior in small laboratory mammals (e.g., mice, rats, tree shrews and small primates). This paradigm is a valuable alternative for the use of a behavioral test battery, since a broad behavioral spectrum of an animal's behavioral profile can be investigated in one single test. The apparatus consists of a box, representing the 'protected' area, separated from a group compartment. A board, on which small cylinders are staggered in three lines, is placed in the center of the box, representing the 'unprotected' area of the set-up. The cognitive abilities of the animals can be measured by baiting some cylinders on the board and measuring the working and reference memory. Other unconditioned behavior, such as activity-related-, anxiety-related- and social behavior, can be observed using this paradigm. Behavioral flexibility and the ability to habituate to a novel environment can additionally be observed by subjecting the animals to multiple trials in the mHB, revealing insight into the animals' adaptive capacities. Due to testing order effects in a behavioral test battery, naïve animals should be used for each individual experiment. By testing multiple behavioral dimensions in a single paradigm and thereby circumventing this issue, the number of experimental animals used is reduced. Furthermore, by avoiding social isolation during testing and without the need to food deprive the animals, the mHB represents a behavioral test system, inducing if any, very low amount of stress.
2015-10-01
Models of Rheumatoid Arthritis PRINCIPAL INVESTIGATOR: Yoel Kloog RECIPIENT: Tel Aviv University TEL AVIV 69978 Israel REPORT DATE: October...TITLE AND SUBTITLE Studying the Immunomodulatory Effects of Small Molecule Ras- Inhibitors in Animal Models of Rheumatoid Arthritis 5a. CONTRACT NUMBER... Rheumatoid Arthritis (RA) display augmented activation of the Ras/Raf/MEK/ERK1/2 signaling pathway, and accordingly overexpression of active K-RAS in
A small nonhuman primate model for filovirus-induced disease.
Carrion, Ricardo; Ro, Youngtae; Hoosien, Kareema; Ticer, Anysha; Brasky, Kathy; de la Garza, Melissa; Mansfield, Keith; Patterson, Jean L
2011-11-25
Ebolavirus and Marburgvirus are members of the filovirus family and induce a fatal hemorrhagic disease in humans and nonhuman primates with 90% case fatality. To develop a small nonhuman primate model for filovirus disease, common marmosets (Callithrix jacchus) were intramuscularly inoculated with wild type Marburgvirus Musoke or Ebolavirus Zaire. The infection resulted in a systemic fatal disease with clinical and morphological features closely resembling human infection. Animals experienced weight loss, fever, high virus titers in tissue, thrombocytopenia, neutrophilia, high liver transaminases and phosphatases and disseminated intravascular coagulation. Evidence of a severe disseminated viral infection characterized principally by multifocal to coalescing hepatic necrosis was seen in EBOV animals. MARV-infected animals displayed only moderate fibrin deposition in the spleen. Lymphoid necrosis and lymphocytic depletion observed in spleen. These findings provide support for the use of the common marmoset as a small nonhuman primate model for filovirus induced hemorrhagic fever. Copyright © 2011 Elsevier Inc. All rights reserved.
Vulnerability of a killer whale social network to disease outbreaks
NASA Astrophysics Data System (ADS)
Guimarães, Paulo R., Jr.; de Menezes, Márcio Argollo; Baird, Robin W.; Lusseau, David; Guimarães, Paulo; Dos Reis, Sérgio F.
2007-10-01
Emerging infectious diseases are among the main threats to conservation of biological diversity. A crucial task facing epidemiologists is to predict the vulnerability of populations of endangered animals to disease outbreaks. In this context, the network structure of social interactions within animal populations may affect disease spreading. However, endangered animal populations are often small and to investigate the dynamics of small networks is a difficult task. Using network theory, we show that the social structure of an endangered population of mammal-eating killer whales is vulnerable to disease outbreaks. This feature was found to be a consequence of the combined effects of the topology and strength of social links among individuals. Our results uncover a serious challenge for conservation of the species and its ecosystem. In addition, this study shows that the network approach can be useful to study dynamical processes in very small networks.
An atmospheric exposure chamber for small animals
NASA Technical Reports Server (NTRS)
Glaser, R. M.; Weiss, H. S.; Pitt, J. F.; Grimard, M.
1982-01-01
The purpose of this project was to design a long-term environmental exposure chamber for small animals. This chamber is capable of producing hypoxic, normoxic and hyperoxic atmospheres which are closely regulated. The chamber, which is of the recycling type, is fashioned after clear plastic germ-free isolators. Oxygen concentration is set and controlled by a paramagnetic O2 analyzer and a 3-way solenoid valve. In this way either O2 or N2 may be provided to the system by way of negative O2 feedback. Relative humidity is maintained at 40-50 percent by a refrigeration type dryer. Carbon dioxide is absorbed by indicating soda lime. A diaphragm pump continuously circulates chamber gas at a high enough flow rate to prevent buildup of CO2 and humidity. This chamber has been used for numerous studies which involve prolonged exposure of small animals to various O2 concentrations.
Multi-institutional MicroCT image comparison of image-guided small animal irradiators
NASA Astrophysics Data System (ADS)
Johnstone, Chris D.; Lindsay, Patricia; E Graves, Edward; Wong, Eugene; Perez, Jessica R.; Poirier, Yannick; Ben-Bouchta, Youssef; Kanesalingam, Thilakshan; Chen, Haijian; E Rubinstein, Ashley; Sheng, Ke; Bazalova-Carter, Magdalena
2017-07-01
To recommend imaging protocols and establish tolerance levels for microCT image quality assurance (QA) performed on conformal image-guided small animal irradiators. A fully automated QA software SAPA (small animal phantom analyzer) for image analysis of the commercial Shelley micro-CT MCTP 610 phantom was developed, in which quantitative analyses of CT number linearity, signal-to-noise ratio (SNR), uniformity and noise, geometric accuracy, spatial resolution by means of modulation transfer function (MTF), and CT contrast were performed. Phantom microCT scans from eleven institutions acquired with four image-guided small animal irradiator units (including the commercial PXi X-RAD SmART and Xstrahl SARRP systems) with varying parameters used for routine small animal imaging were analyzed. Multi-institutional data sets were compared using SAPA, based on which tolerance levels for each QA test were established and imaging protocols for QA were recommended. By analyzing microCT data from 11 institutions, we established image QA tolerance levels for all image quality tests. CT number linearity set to R 2 > 0.990 was acceptable in microCT data acquired at all but three institutions. Acceptable SNR > 36 and noise levels <55 HU were obtained at five of the eleven institutions, where failing scans were acquired with current-exposure time of less than 120 mAs. Acceptable spatial resolution (>1.5 lp mm-1 for MTF = 0.2) was obtained at all but four institutions due to their large image voxel size used (>0.275 mm). Ten of the eleven institutions passed the set QA tolerance for geometric accuracy (<1.5%) and nine of the eleven institutions passed the QA tolerance for contrast (>2000 HU for 30 mgI ml-1). We recommend performing imaging QA with 70 kVp, 1.5 mA, 120 s imaging time, 0.20 mm voxel size, and a frame rate of 5 fps for the PXi X-RAD SmART. For the Xstrahl SARRP, we recommend using 60 kVp, 1.0 mA, 240 s imaging time, 0.20 mm voxel size, and 6 fps. These imaging protocols should result in high quality images that pass the set tolerance levels on all systems. Average SAPA computation time for complete QA analysis for a 0.20 mm voxel, 400 slice Shelley phantom microCT data set was less than 20 s. We present image quality assurance recommendations for image-guided small animal radiotherapy systems that can aid researchers in maintaining high image quality, allowing for spatially precise conformal dose delivery to small animals.
Jiang, Ying; Zhang, Xuemei; Mu, Hongjie; Hua, Hongchen; Duan, Dongyu; Yan, Xiuju; Wang, Yiyun; Meng, Qingqing; Lu, Xiaoyan; Wang, Aiping; Liu, Wanhui; Li, Youxin; Sun, Kaoxiang
2018-11-01
A microsphere-gel in situ forming implant (MS-Gel ISFI) dual-controlled drug delivery system was applied to a high water-soluble small-molecule compound Rasagiline mesylate (RM) for effective treatment of Parkinson's disease. This injectable complex depot system combined an in situ phase transition gel with high drug-loading and encapsulation efficiency RM-MS prepared by a modified emulsion-phase separation method and optimized by Box-Behnken design. It was evaluated for in vitro drug release, in vivo pharmacokinetics, and in vivo pharmacodynamics. We found that the RM-MS-Gel ISFI system showed no initial burst release and had a long period of in vitro drug release (60 days). An in vivo pharmacokinetic study indicated a significant reduction (p < .01) in the initial high plasma drug concentration of the RM-MS-Gel ISFI system compared to that of the single RM-MS and RM-in situ gel systems after intramuscular injection to rats. A pharmacodynamic study demonstrated a significant reduction (p < .05) in 6-hydroxydopamine-induced contralateral rotation behavior and an effective improvement (p < .05) in dopamine levels in the striatum of the lesioned side after 28 days in animals treated with the RM-MS-Gel ISFI compared with that of animals treated with saline. MS-embedded in situ phase transition gel is superior for use as a biodegradable and injectable sustained drug delivery system with a low initial burst and long period of drug release for highly hydrophilic small molecule drugs.
Conservation of small RNA pathways in platypus
Murchison, Elizabeth P.; Kheradpour, Pouya; Sachidanandam, Ravi; Smith, Carly; Hodges, Emily; Xuan, Zhenyu; Kellis, Manolis; Grützner, Frank; Stark, Alexander; Hannon, Gregory J.
2008-01-01
Small RNA pathways play evolutionarily conserved roles in gene regulation and defense from parasitic nucleic acids. The character and expression patterns of small RNAs show conservation throughout animal lineages, but specific animal clades also show variations on these recurring themes, including species-specific small RNAs. The monotremes, with only platypus and four species of echidna as extant members, represent the basal branch of the mammalian lineage. Here, we examine the small RNA pathways of monotremes by deep sequencing of six platypus and echidna tissues. We find that highly conserved microRNA species display their signature tissue-specific expression patterns. In addition, we find a large rapidly evolving cluster of microRNAs on platypus chromosome X1, which is unique to monotremes. Platypus and echidna testes contain a robust Piwi-interacting (piRNA) system, which appears to be participating in ongoing transposon defense. PMID:18463306
Conservation of small RNA pathways in platypus.
Murchison, Elizabeth P; Kheradpour, Pouya; Sachidanandam, Ravi; Smith, Carly; Hodges, Emily; Xuan, Zhenyu; Kellis, Manolis; Grützner, Frank; Stark, Alexander; Hannon, Gregory J
2008-06-01
Small RNA pathways play evolutionarily conserved roles in gene regulation and defense from parasitic nucleic acids. The character and expression patterns of small RNAs show conservation throughout animal lineages, but specific animal clades also show variations on these recurring themes, including species-specific small RNAs. The monotremes, with only platypus and four species of echidna as extant members, represent the basal branch of the mammalian lineage. Here, we examine the small RNA pathways of monotremes by deep sequencing of six platypus and echidna tissues. We find that highly conserved microRNA species display their signature tissue-specific expression patterns. In addition, we find a large rapidly evolving cluster of microRNAs on platypus chromosome X1, which is unique to monotremes. Platypus and echidna testes contain a robust Piwi-interacting (piRNA) system, which appears to be participating in ongoing transposon defense.