Sample records for small detection volume

  1. Quantification of Protozoa and Viruses from Small Water Volumes

    PubMed Central

    Bonilla, J. Alfredo; Bonilla, Tonya D.; Abdelzaher, Amir M.; Scott, Troy M.; Lukasik, Jerzy; Solo-Gabriele, Helena M.; Palmer, Carol J.

    2015-01-01

    Large sample volumes are traditionally required for the analysis of waterborne pathogens. The need for large volumes greatly limits the number of samples that can be processed. The goals of this study were to compare extraction and detection procedures for quantifying protozoan parasites and viruses from small volumes of marine water. The intent was to evaluate a logistically simpler method of sample collection and processing that would facilitate direct pathogen measures as part of routine monitoring programs. Samples were collected simultaneously using a bilayer device with protozoa capture by size (top filter) and viruses capture by charge (bottom filter). Protozoan detection technologies utilized for recovery of Cryptosporidium spp. and Giardia spp. were qPCR and the more traditional immunomagnetic separation—IFA-microscopy, while virus (poliovirus) detection was based upon qPCR versus plaque assay. Filters were eluted using reagents consistent with the downstream detection technologies. Results showed higher mean recoveries using traditional detection methods over qPCR for Cryptosporidium (91% vs. 45%) and poliovirus (67% vs. 55%) whereas for Giardia the qPCR-based methods were characterized by higher mean recoveries (41% vs. 28%). Overall mean recoveries are considered high for all detection technologies. Results suggest that simultaneous filtration may be suitable for isolating different classes of pathogens from small marine water volumes. More research is needed to evaluate the suitability of this method for detecting pathogens at low ambient concentration levels. PMID:26114244

  2. Quantification of Protozoa and Viruses from Small Water Volumes.

    PubMed

    Bonilla, J Alfredo; Bonilla, Tonya D; Abdelzaher, Amir M; Scott, Troy M; Lukasik, Jerzy; Solo-Gabriele, Helena M; Palmer, Carol J

    2015-06-24

    Large sample volumes are traditionally required for the analysis of waterborne pathogens. The need for large volumes greatly limits the number of samples that can be processed. The aims of this study were to compare extraction and detection procedures for quantifying protozoan parasites and viruses from small volumes of marine water. The intent was to evaluate a logistically simpler method of sample collection and processing that would facilitate direct pathogen measures as part of routine monitoring programs. Samples were collected simultaneously using a bilayer device with protozoa capture by size (top filter) and viruses capture by charge (bottom filter). Protozoan detection technologies utilized for recovery of Cryptosporidium spp. and Giardia spp. were qPCR and the more traditional immunomagnetic separation-IFA-microscopy, while virus (poliovirus) detection was based upon qPCR versus plaque assay. Filters were eluted using reagents consistent with the downstream detection technologies. Results showed higher mean recoveries using traditional detection methods over qPCR for Cryptosporidium (91% vs. 45%) and poliovirus (67% vs. 55%) whereas for Giardia the qPCR-based methods were characterized by higher mean recoveries (41% vs. 28%). Overall mean recoveries are considered high for all detection technologies. Results suggest that simultaneous filtration may be suitable for isolating different classes of pathogens from small marine water volumes. More research is needed to evaluate the suitability of this method for detecting pathogens at low ambient concentration levels.

  3. Towards Universal Screening for Toxoplasmosis: Rapid, Cost-effective and Simultaneous Detection of Toxoplasma Anti-IgG, IgM and IgA Antibodies Using Very Small Serum Volumes

    EPA Pesticide Factsheets

    No dataset associated with this publication.This dataset is associated with the following publication:Augustine, S. Towards Universal Screening for Toxoplasmosis: Rapid, Cost-effective and Simultaneous Detection of Toxoplasma Anti-IgG, IgM and IgA Antibodies Using Very Small Serum Volumes. JOURNAL OF CLINICAL MICROBIOLOGY. American Society for Microbiology, Washington, DC, USA, 56(7): 1-2, (2016).

  4. Implications of improved diagnostic imaging of small nodal metastases in head and neck cancer: Radiotherapy target volume transformation and dose de-escalation.

    PubMed

    van den Bosch, Sven; Vogel, Wouter V; Raaijmakers, Cornelis P; Dijkema, Tim; Terhaard, Chris H J; Al-Mamgani, Abrahim; Kaanders, Johannes H A M

    2018-05-03

    Diagnostic imaging continues to evolve, and now has unprecedented accuracy for detecting small nodal metastasis. This influences the tumor load in elective target volumes and subsequently has consequences for the radiotherapy dose required to control disease in these volumes. Small metastases that used to remain subclinical and were included in elective volumes, will nowadays be detected and included in high-dose volumes. Consequentially, high-dose volumes will more often contain low-volume disease. These target volume transformations lead to changes in the tumor burden in elective and "gross" tumor volumes with implications for the radiotherapy dose prescribed to these volumes. For head and neck tumors, nodal staging has evolved from mere palpation to combinations of high-resolution imaging modalities. A traditional nodal gross tumor volume in the neck typically had a minimum diameter of 10-15 mm, while nowadays much smaller tumor deposits are detected in lymph nodes. However, the current dose levels for elective nodal irradiation were empirically determined in the 1950s, and have not changed since. In this report the radiobiological consequences of target volume transformation caused by modern imaging of the neck are evaluated, and theoretically derived reductions of dose in radiotherapy for head and neck cancer are proposed. The concept of target volume transformation and subsequent strategies for dose adaptation applies to many other tumor types as well. Awareness of this concept may result in new strategies for target definition and selection of dose levels with the aim to provide optimal tumor control with less toxicity. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  5. COMPARISON OF THORACIC ULTRASONOGRAPHY AND RADIOGRAPHY FOR THE DETECTION OF INDUCED SMALL VOLUME PNEUMOTHORAX IN THE HORSE.

    PubMed

    Partlow, Jessica; David, Florent; Hunt, Luanne Michelle; Relave, Fabien; Blond, Laurent; Pinilla, Manuel; Lavoie, Jean-Pierre

    2017-05-01

    Small volume pneumothorax can be challenging to diagnose in horses. The current standard method for diagnosis is standing thoracic radiography. We hypothesized that thoracic ultrasonography would be more sensitive. Objectives of this prospective, experimental study were to describe a thoracic ultrasound method for detection of small volume pneumothorax in horses and to compare results of radiography and ultrasound in a sample of horses with induced small volume pneumothorax. Six mature healthy horses were recruited for this study. For each horse, five 50 ml air boluses were sequentially introduced via a teat cannula into the pleural space. Lateral thoracic radiographs and standardized ultrasound (2D and M-mode) examinations of both hemithoraces were performed following administration of each 50 ml air bolus. Radiographs and ultrasound images/videos were analyzed for detection of pneumothorax by four independent investigators who were unaware of treatment status. Sensitivity, specificity, positive predictive values, negative predictive values, and agreement among investigators (Kappa test, κ) were calculated for radiography, 2D and M-mode ultrasound. Comparisons were made using a chi-squared exact test with significance set at P < 0.05. Two-dimensional (84%) and M-mode (80%) ultrasound were more sensitive than radiography (48%) for pneumothorax detection (P = 0.02 and P = 0.04, respectively). Specificity and positive predictive values were similar for all three imaging modalities (P = 1). Agreement between investigators for pneumothorax detection was excellent for 2D ultrasound (κ = 1), very good for M-mode ultrasound (κ = 0.87), and good for radiography (κ = 0.79). Findings from this experimental study supported the use of thoracic ultrasonography as a diagnostic method for detecting pneumothorax in horses. © 2017 American College of Veterinary Radiology.

  6. Development of a high-sensitivity and portable cell using Helmholtz resonance for noninvasive blood glucose-level measurement based on photoacoustic spectroscopy.

    PubMed

    Tachibana, K; Okada, K; Kobayashi, R; Ishihara, Y

    2016-08-01

    We describe the possibility of high-sensitivity noninvasive blood glucose measurement based on photoacoustic spectroscopy (PAS). The demand for noninvasive blood glucose-level measurement has increased due to the explosive increase in diabetic patients. We have developed a noninvasive blood glucose-level measurement based on PAS. The conventional method uses a straight-type resonant cell. However, the cell volume is large, which results in a low detection sensitivity and difficult portability. In this paper, a small-sized Helmholtz-type resonant cell is proposed to improve detection sensitivity and portability by reducing the cell dead volume. First, the acoustic property of the small-sized Helmholtz-type resonant cell was evaluated by performing an experiment using a silicone rubber. As a result, the detection sensitivity of the small-sized Helmholtz-type resonant cell was approximately two times larger than that of the conventional straight-type resonant cell. In addition, the inside volume was approximately 30 times smaller. Second, the detection limits of glucose concentration were estimated by performing an experiment using glucose solutions. The experimental results showed that a glucose concentration of approximately 1% was detected by the small-sized Helmholtz-type resonant cell. Although these results on the sensitivity of blood glucose-level measurement are currently insufficient, they suggest that miniaturization of a resonance cell is effective in the application of noninvasive blood glucose-level measurement.

  7. Infrared astronomical satellite (IRAS) catalogs and atlases. Volume 7: The small scale structure catalog

    NASA Technical Reports Server (NTRS)

    Helou, George (Editor); Walker, D. W. (Editor)

    1988-01-01

    The Infrared Astronomical Satellite (IRAS) was launched January 26, 1983. During its 300-day mission, it surveyed over 96 pct of the celestial sphere at four infrared wavelengths, centered approximately at 12, 25, 60, and 100 microns. Volume 1 describes the instrument, the mission, and the data reduction process. Volumes 2 through 6 present the observations of the approximately 245,000 individual point sources detected by IRAS; each volume gives sources within a specified range of declination. Volume 7 gives the observations of the approximately 16,000 sources spatially resolved by IRAS and smaller than 8'. This is Volume 7, The Small Scale Structure Catalog.

  8. Possible standoff detection of ionizing radiation using high-power THz electromagnetic waves

    NASA Astrophysics Data System (ADS)

    Nusinovich, Gregory S.; Sprangle, Phillip; Romero-Talamas, Carlos A.; Rodgers, John; Pu, Ruifeng; Kashyn, Dmytro G.; Antonsen, Thomas M., Jr.; Granatstein, Victor L.

    2012-06-01

    Recently, a new method of remote detection of concealed radioactive materials was proposed. This method is based on focusing high-power short wavelength electromagnetic radiation in a small volume where the wave electric field exceeds the breakdown threshold. In the presence of free electrons caused by ionizing radiation, in this volume an avalanche discharge can then be initiated. When the wavelength is short enough, the probability of having even one free electron in this small volume in the absence of additional sources of ionization is low. Hence, a high breakdown rate will indicate that in the vicinity of this volume there are some materials causing ionization of air. To prove this concept a 0.67 THz gyrotron delivering 200-300 kW power in 10 microsecond pulses is under development. This method of standoff detection of concealed sources of ionizing radiation requires a wide range of studies, viz., evaluation of possible range, THz power and pulse duration, production of free electrons in air by gamma rays penetrating through container walls, statistical delay time in initiation of the breakdown in the case of low electron density, temporal evolution of plasma structure in the breakdown and scattering of THz radiation from small plasma objects. Most of these issues are discussed in the paper.

  9. Preparative electrophoresis with on-column optical fiber monitoring and direct elution into a minimized volume.

    PubMed

    Jackson, George W; Willson, Richard

    2005-11-01

    A "column-format" preparative electrophoresis device which obviates the need for gel extraction or secondary electro-elution steps is described. Separated biomolecules are continuously detected and eluted directly into a minimal volume of free solution for subsequent use. An optical fiber allows the species of interest to be detected just prior to elution from the gel column, and a small collection volume is created by addition of an ion-exchange membrane near the end of the column.

  10. Prototype of microbolometer thermal infrared camera for forest fire detection from space

    NASA Astrophysics Data System (ADS)

    Guerin, Francois; Dantes, Didier; Bouzou, Nathalie; Chorier, Philippe; Bouchardy, Anne-Marie; Rollin, Joël.

    2017-11-01

    The contribution of the thermal infrared (TIR) camera to the Earth observation FUEGO mission is to participate; to discriminate the clouds and smoke; to detect the false alarms of forest fires; to monitor the forest fires. Consequently, the camera needs a large dynamic range of detectable radiances. A small volume, low mass and power are required by the small FUEGO payload. These specifications can be attractive for other similar missions.

  11. Detection of IDH1 mutation in the plasma of patients with glioma.

    PubMed

    Boisselier, Blandine; Gállego Pérez-Larraya, Jaime; Rossetto, Marta; Labussière, Marianne; Ciccarino, Pietro; Marie, Yannick; Delattre, Jean-Yves; Sanson, Marc

    2012-10-16

    The IDH1(R132H) mutation is both a strong prognostic predictor and a diagnostic hallmark of gliomas and therefore has major clinical relevance. Here, we developed a new technique to detect the IDH1(R132H) mutation in the plasma of patients with glioma. Small-size DNA (150-250 base pairs) was extracted from the plasma of 31 controls and 80 patients with glioma with known IDH1(R132H) status and correlated with MRI data. The IDH1(R132H) mutation was detected by a combination of coamplification at lower denaturation temperature and digital PCR. The small size DNA concentration was 1.2 ng/mL (range 0.1-6.6) in controls vs 1.2 ng/mL (range 0.1-50.3) in patients with glioma (p = not significant) and 0.9 ng/mL (0.0-3.0) in low-grade gliomas vs 1.5 ng/mL in high-grade gliomas (p < 0.01). The small size DNA concentration correlated with enhancing tumor volume (1.6 ng/mL [0.4-24.9] when <10 cm(3) and 14.0 ng/mL [0.6-50.3] when ≥10 cm(3)). The IDH1(R132H) mutation was detected in 15 out of 25 plasma DNA mixtures (60%) from patients with mutated tumors and in none of the 14 patients with a nonmutated tumor. The sensitivity increased with enhancing tumor volume (3/9 in nonenhancing tumors, 6/10 for enhancing volume <10 cm(3), and 6/6 for enhancing volume ≥10 cm(3)). With a specificity of 100% and a sensitivity related to the tumor volume and contrast enhancement, IDH1(R132H) identification has a valuable diagnostic accuracy in patients not amenable to biopsy.

  12. Modified Technique For Chemisorption Measurements

    NASA Technical Reports Server (NTRS)

    Schryer, David R.; Brown, Kenneth G.; Schryer, Jacqueline

    1989-01-01

    In measurements of chemisorption of CO on Pt/SnO2 catalyst observed that if small numbers of relatively large volumes of adsorbate gas are passed through sample, very little removal of CO detected. In these cases little or no CO has been chemisorbed on Pt/SnO2. Technique of using large number of small volumes of adsorbate gas to measure chemisorption applicable to many gas/material combinations other than CO on Pt/SnO2. Volume used chosen so that at least 10 percent of adsorbate gas removed during each exposure.

  13. Absorbance and fluorometric sensing with capillary wells microplates.

    PubMed

    Tan, Han Yen; Cheong, Brandon Huey-Ping; Neild, Adrian; Liew, Oi Wah; Ng, Tuck Wah

    2010-12-01

    Detection and readout from small volume assays in microplates are a challenge. The capillary wells microplate approach [Ng et al., Appl. Phys. Lett. 93, 174105 (2008)] offers strong advantages in small liquid volume management. An adapted design is described and shown here to be able to detect, in a nonimaging manner, fluorescence and absorbance assays minus the error often associated with meniscus forming at the air-liquid interface. The presence of bubbles in liquid samples residing in microplate wells can cause inaccuracies. Pipetting errors, if not adequately managed, can result in misleading data and wrong interpretations of assay results; particularly in the context of high throughput screening. We show that the adapted design is also able to detect for bubbles and pipetting errors during actual assay runs to ensure accuracy in screening.

  14. Transport of Gas and Solutes in Permeable Estuarine Sediments

    DTIC Science & Technology

    2012-09-30

    produce his Ph.D. dissertation based on this reserach . The acoustic method for detecting and measuring small gas bubbles in marine sands. This...the detection and quantification of small free gas volumes in sandy coastal sediments. After introducing and explaining the instrument, the paper ...influence the sediment erosion threshold, biogeochemical zonations, living space for organisms and thereby the role of the sediments in the cycles of

  15. Absorbance and fluorometric sensing with capillary wells microplates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tan, Han Yen; Cheong, Brandon Huey-Ping; Neild, Adrian

    2010-12-15

    Detection and readout from small volume assays in microplates are a challenge. The capillary wells microplate approach [Ng et al., Appl. Phys. Lett. 93, 174105 (2008)] offers strong advantages in small liquid volume management. An adapted design is described and shown here to be able to detect, in a nonimaging manner, fluorescence and absorbance assays minus the error often associated with meniscus forming at the air-liquid interface. The presence of bubbles in liquid samples residing in microplate wells can cause inaccuracies. Pipetting errors, if not adequately managed, can result in misleading data and wrong interpretations of assay results; particularly inmore » the context of high throughput screening. We show that the adapted design is also able to detect for bubbles and pipetting errors during actual assay runs to ensure accuracy in screening.« less

  16. A new single crystal diamond dosimeter for small beam: comparison with different commercial active detectors.

    PubMed

    Marsolat, F; Tromson, D; Tranchant, N; Pomorski, M; Le Roy, M; Donois, M; Moignau, F; Ostrowsky, A; De Carlan, L; Bassinet, C; Huet, C; Derreumaux, S; Chea, M; Cristina, K; Boisserie, G; Bergonzo, P

    2013-11-07

    Recent developments of new therapy techniques using small photon beams, such as stereotactic radiotherapy, require suitable detectors to determine the delivered dose with a high accuracy. The dosimeter has to be as close as possible to tissue equivalence and to exhibit a small detection volume compared to the size of the irradiation field, because of the lack of lateral electronic equilibrium in small beam. Characteristics of single crystal diamond (tissue equivalent material Z = 6, high density) make it an ideal candidate to fulfil most of small beam dosimetry requirements. A commercially available Element Six electronic grade synthetic diamond was used to develop a single crystal diamond dosimeter (SCDDo) with a small detection volume (0.165 mm(3)). Long term stability was studied by irradiating the SCDDo in a (60)Co beam over 14 h. A good stability (deviation less than ± 0.1%) was observed. Repeatability, dose linearity, dose rate dependence and energy dependence were studied in a 10 × 10 cm(2) beam produced by a Varian Clinac 2100 C linear accelerator. SCDDo lateral dose profile, depth dose curve and output factor (OF) measurements were performed for small photon beams with a micro multileaf collimator m3 (BrainLab) attached to the linac. This study is focused on the comparison of SCDDo measurements to those obtained with different commercially available active detectors: an unshielded silicon diode (PTW 60017), a shielded silicon diode (Sun Nuclear EDGE), a PinPoint ionization chamber (PTW 31014) and two natural diamond detectors (PTW 60003). SCDDo presents an excellent spatial resolution for dose profile measurements, due to its small detection volume. Low energy dependence (variation of 1.2% between 6 and 18 MV photon beam) and low dose rate dependence of the SCDDo (variation of 1% between 0.53 and 2.64 Gy min(-1)) are obtained, explaining the good agreement between the SCDDo and the efficient unshielded diode (PTW 60017) in depth dose curve measurements. For field sizes ranging from 0.6 × 0.6 to 10 × 10 cm(2), OFs obtained with the SCDDo are between the OFs measured with the PinPoint ionization chamber and the Sun Nuclear EDGE diode that are known to respectively underestimate and overestimate OF values in small beam, due to the large detection volume of the chamber and the non-water equivalence of both detectors.

  17. Detection of the presence of Chlamydia trachomatis bacteria using diffusing wave spectroscopy with a small number of scatterers

    NASA Astrophysics Data System (ADS)

    Ulyanov, Sergey; Ulianova, Onega; Filonova, Nadezhda; Moiseeva, Yulia; Zaitsev, Sergey; Saltykov, Yury; Polyanina, Tatiana; Lyapina, Anna; Kalduzova, Irina; Larionova, Olga; Utz, Sergey; Feodorova, Valentina

    2018-04-01

    Theory of diffusing wave spectroscopy has been firstly adapted to the problem of rapid detection of Chlamydia trachomatis bacteria in blood samples of Chlamydia patients. Formula for correlation function of temporal fluctuations of speckle intensity is derived for the case of small number of scattering events. Dependence of bandwidth of spectrum on average number of scatterers is analyzed. Set-up for detection of the presence of C. trachomatis cells in aqueous suspension is designed. Good agreement between theoretical results and experimental data is shown. Possibility of detection of the presence of C. trachomatis cells in probing volume using diffusing wave spectroscopy with a small number of scatterers is successfully demonstrated for the first time.

  18. Brain atrophy and cerebral small vessel disease: a prospective follow-up study.

    PubMed

    Nitkunan, Arani; Lanfranconi, Silvia; Charlton, Rebecca A; Barrick, Thomas R; Markus, Hugh S

    2011-01-01

    cerebral small vessel disease (SVD) is the most common cause of vascular dementia. Interest in the use of surrogate markers is increasing. The aims of this study were to determine if brain volume was different between patients with SVD and control subjects, whether it correlated with cognition in SVD, and whether changes in brain volume could be detected during prospective follow-up. thirty-five patients (mean age, 68.8 years) who had a lacunar stroke and radiological evidence of confluent leukoaraiosis and 70 age- and gender-matched control subjects were recruited. Whole-brain T1-weighted imaging and neuropsychological testing were performed after 1 year on all patients and after 2 years for the control subjects. Fully automated software was used to determine brain volume and percentage brain volume change. An executive function score was derived. there was a significant difference in brain volume between the patients with SVD and control subjects (mean ± SD [mL] 1529 ± 84 versus 1573 ± 69, P=0.019). In the patients with SVD, there was a significant association between brain volume and executive function (r=0.501, P<0.05). The mean ± SD yearly brain atrophy rate for patients with SVD and control subjects was significantly different (-0.914% ± 0.8% versus -0.498% ± 0.4%, respectively, P=0.017). No change in executive function score was detected over this period. brain volume is reduced in SVD and a decline is detectable prospectively. The correlation with executive function at a cross-sectional level and the change in brain volume with time are both promising for the use of brain atrophy as a surrogate marker of SVD progression.

  19. Seismic monitoring of small alpine rockfalls - validity, precision and limitations

    NASA Astrophysics Data System (ADS)

    Dietze, Michael; Mohadjer, Solmaz; Turowski, Jens M.; Ehlers, Todd A.; Hovius, Niels

    2017-10-01

    Rockfall in deglaciated mountain valleys is perhaps the most important post-glacial geomorphic process for determining the rates and patterns of valley wall erosion. Furthermore, rockfall poses a significant hazard to inhabitants and motivates monitoring efforts in populated areas. Traditional rockfall detection methods, such as aerial photography and terrestrial laser scanning (TLS) data evaluation, provide constraints on the location and released volume of rock but have limitations due to significant time lags or integration times between surveys, and deliver limited information on rockfall triggering mechanisms and the dynamics of individual events. Environmental seismology, the study of seismic signals emitted by processes at the Earth's surface, provides a complementary solution to these shortcomings. However, this approach is predominantly limited by the strength of the signals emitted by a source and their transformation and attenuation towards receivers. To test the ability of seismic methods to identify and locate small rockfalls, and to characterise their dynamics, we surveyed a 2.16 km2 large, near-vertical cliff section of the Lauterbrunnen Valley in the Swiss Alps with a TLS device and six broadband seismometers. During 37 days in autumn 2014, 10 TLS-detected rockfalls with volumes ranging from 0.053 ± 0.004 to 2.338 ± 0.085 m3 were independently detected and located by the seismic approach, with a deviation of 81-29+59 m (about 7 % of the average inter-station distance of the seismometer network). Further potential rockfalls were detected outside the TLS-surveyed cliff area. The onset of individual events can be determined within a few milliseconds, and their dynamics can be resolved into distinct phases, such as detachment, free fall, intermittent impact, fragmentation, arrival at the talus slope and subsequent slope activity. The small rockfall volumes in this area require significant supervision during data processing: 2175 initially picked potential events reduced to 511 potential events after applying automatic rejection criteria. The 511 events needed to be inspected manually to reveal 19 short earthquakes and 37 potential rockfalls, including the 10 TLS-detected events. Rockfall volume does not show a relationship with released seismic energy or peak amplitude at this spatial scale due to the dominance of other, process-inherent factors, such as fall height, degree of fragmentation, and subsequent talus slope activity. The combination of TLS and environmental seismology provides, despite the significant amount of manual data processing, a detailed validation of seismic detection of small volume rockfalls, and revealed unprecedented temporal, spatial and geometric details about rockfalls in steep mountainous terrain.

  20. A computer system for analysis and transmission of spirometry waveforms using volume sampling.

    PubMed

    Ostler, D V; Gardner, R M; Crapo, R O

    1984-06-01

    A microprocessor-controlled data gathering system for telemetry and analysis of spirometry waveforms was implemented using a completely digital design. Spirometry waveforms were obtained from an optical shaft encoder attached to a rolling seal spirometer. Time intervals between 10-ml volume changes (volume sampling) were stored. The digital design eliminated problems of analog signal sampling. The system measured flows up to 12 liters/sec with 5% accuracy and volumes up to 10 liters with 1% accuracy. Transmission of 10 waveforms took about 3 min. Error detection assured that no data were lost or distorted during transmission. A pulmonary physician at the central hospital reviewed the volume-time and flow-volume waveforms and interpretations generated by the central computer before forwarding the results and consulting with the rural physician. This system is suitable for use in a major hospital, rural hospital, or small clinic because of the system's simplicity and small size.

  1. In vitro platelet quality in storage containers used for pediatric transfusions.

    PubMed

    Weiss, Sandra; Scammell, Kenneth; Levin, Elena; Culibrk, Brankica; Zolfaghari, Sima; Gyöngyössy-Issa, Maria I C; Acker, Jason P

    2012-08-01

    The in vitro quality of small-volume platelet (PLT) aliquots for pediatric transfusions was assessed to determine the best practice approach. Small volumes (50 mL) of single apheresis PLT components (APCs), collected on either CaridianBCT Trima or Haemonetics MCS+ instruments, were aliquoted on Days 2, 3, 4, and 5 postcollection into Fenwal PL1240 or 4R2014 bags or 60-mL polypropylene syringes. Samples were tested for in vitro quality at their recommended expiry times (4 hr for 4R2014 bags and syringes or Day 5 for PL1240 bags). Assays included pH, CD62P expression, and metabolic measures. CD62P expression increased throughout storage in all containers. Among the small-volume containers, pH, pCO(2) , lactate, and bicarbonate varied considerably. Regardless of the day of aliquoting, pCO(2) was significantly higher and pO(2) was significantly lower in gas-impermeable syringes than other containers. No bacterial growth was detected in any sample. The quality of APCs aliquoted into small-volume containers meets regulatory requirements and is generally equivalent to that of full-volume APCs at expiry. © 2012 American Association of Blood Banks.

  2. Influence of carbon nanoparticle modification on the mechanical and electrical properties of epoxy in small volumes.

    PubMed

    Leopold, Christian; Augustin, Till; Schwebler, Thomas; Lehmann, Jonas; Liebig, Wilfried V; Fiedler, Bodo

    2017-11-15

    The influence of nanoparticle morphology and filler content on the mechanical and electrical properties of carbon nanoparticle modified epoxy is investigated regarding small volumes. Three types of particles, representing spherical, tubular and layered morphologies are used. A clear size effect of increasing true failure strength with decreasing volume is found for neat and carbon black modified epoxy. Carbon nanotube (CNT) modified epoxy exhibits high potential for strength increase, but dispersion and purity are critical. In few layer graphene modified epoxy, particles are larger than statistically distributed defects and initiate cracks, counteracting any size effect. Different toughness increasing mechanisms on the nano- and micro-scale depending on particle morphology are discussed based on scanning electron microscopy images. Electrical percolation thresholds in the small volume fibres are significantly higher compared to bulk volume, with CNT being found to be the most suitable morphology to form electrical conductive paths. Good correlation between electrical resistance change and stress strain behaviour under tensile loads is observed. The results show the possibility to detect internal damage in small volumes by measuring electrical resistance and therefore indicate to the high potential for using CNT modified polymers in fibre reinforced plastics as a multifunctional, self-monitoring material with improved mechanical properties. Copyright © 2017. Published by Elsevier Inc.

  3. Susceptibility-matched plugs for microcoil NMR probes

    NASA Astrophysics Data System (ADS)

    Kc, Ravi; Gowda, Yashas N.; Djukovic, Danijel; Henry, Ian D.; Park, Gregory H. J.; Raftery, Daniel

    2010-07-01

    For mass-limited samples, the residual sample volume outside the detection coil is an important concern, as is good base line resolution. Here, we present the construction and evaluation of magnetic susceptibility-matched plugs for microcoil NMR sample cells which address these issues. Mixed-epoxy glue and ultem tube plugs that have susceptibility values close to those of perfluorocarbon FC-43 (fluorinert) and copper were used in small volume (0.5-2 μL) and larger volume (15-20 μL) thin glass capillary sample cells. Using these plugs, the sample volume efficiency (i.e. ratio of active volume to total sample volume in the microcoil NMR cell) was improved by 6-12-fold without sensitivity and resolution trade-offs. Comparison with laser etched or heat etched microcoil sample cells is provided. The approaches described are potentially useful in metabolomics for biomarkers detection in mass limited biological samples.

  4. Susceptibility-matched plugs for microcoil NMR probes.

    PubMed

    Kc, Ravi; Gowda, Yashas N; Djukovic, Danijel; Henry, Ian D; Park, Gregory H J; Raftery, Daniel

    2010-07-01

    For mass-limited samples, the residual sample volume outside the detection coil is an important concern, as is good base line resolution. Here, we present the construction and evaluation of magnetic susceptibility-matched plugs for microcoil NMR sample cells which address these issues. Mixed-epoxy glue and ultem tube plugs that have susceptibility values close to those of perfluorocarbon FC-43 (fluorinert) and copper were used in small volume (0.5-2 microL) and larger volume (15-20 microL) thin glass capillary sample cells. Using these plugs, the sample volume efficiency (i.e. ratio of active volume to total sample volume in the microcoil NMR cell) was improved by 6-12-fold without sensitivity and resolution trade-offs. Comparison with laser etched or heat etched microcoil sample cells is provided. The approaches described are potentially useful in metabolomics for biomarkers detection in mass limited biological samples. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  5. Susceptibility-matched plugs for microcoil NMR probes

    PubMed Central

    Kc, Ravi; Gowda, Yashas N.; Djukovic, Danijel; Henry, Ian D; Park, Gregory H J; Raftery, Daniel

    2010-01-01

    For mass limited samples, the residual sample volume outside the detection coil is an important concern, as is good base line resolution. Here, we present the construction and evaluation of magnetic susceptibility-matched plugs for microcoil NMR sample cells which address these issues. Mixed-epoxy glue and ultem tube plugs that have susceptibility values close to those of perfluorocarbon FC-43 (fluorinert) and copper were used in small volume (0.5 to 2 μL) and larger volume (15 to 20 μL) thin glass capillary sample cells. Using these plugs, the sample volume efficiency (i.e. ratio of active volume to total sample volume in the microcoil NMR cell) was improved by 6 to 12 fold without sensitivity and resolution trade-offs. Comparison with laser etched or heat etched microcoil sample cells is provided. The approaches described are potentially useful in metabolomics for biomarkers detection in mass limited biological samples. PMID:20510638

  6. Fully Automated Centrifugal Microfluidic Device for Ultrasensitive Protein Detection from Whole Blood.

    PubMed

    Park, Yang-Seok; Sunkara, Vijaya; Kim, Yubin; Lee, Won Seok; Han, Ja-Ryoung; Cho, Yoon-Kyoung

    2016-04-16

    Enzyme-linked immunosorbent assay (ELISA) is a promising method to detect small amount of proteins in biological samples. The devices providing a platform for reduced sample volume and assay time as well as full automation are required for potential use in point-of-care-diagnostics. Recently, we have demonstrated ultrasensitive detection of serum proteins, C-reactive protein (CRP) and cardiac troponin I (cTnI), utilizing a lab-on-a-disc composed of TiO2 nanofibrous (NF) mats. It showed a large dynamic range with femto molar (fM) detection sensitivity, from a small volume of whole blood in 30 min. The device consists of several components for blood separation, metering, mixing, and washing that are automated for improved sensitivity from low sample volumes. Here, in the video demonstration, we show the experimental protocols and know-how for the fabrication of NFs as well as the disc, their integration and the operation in the following order: processes for preparing TiO2 NF mat; transfer-printing of TiO2 NF mat onto the disc; surface modification for immune-reactions, disc assembly and operation; on-disc detection and representative results for immunoassay. Use of this device enables multiplexed analysis with minimal consumption of samples and reagents. Given the advantages, the device should find use in a wide variety of applications, and prove beneficial in facilitating the analysis of low abundant proteins.

  7. Confocal Raman Microscopy for in Situ Measurement of Octanol-Water Partitioning within the Pores of Individual C18-Functionalized Chromatographic Particles.

    PubMed

    Kitt, Jay P; Harris, Joel M

    2015-05-19

    Octanol-water partitioning is one of the most widely used predictors of hydrophobicity and lipophilicity. Traditional methods for measuring octanol-water partition coefficients (K(ow)), including shake-flasks and generator columns, require hours for equilibration and milliliter quantities of sample solution. These challenges have led to development of smaller-scale methods for measuring K(ow). Recent advances in microfluidics have produced faster and smaller-volume approaches to measuring K(ow). As flowing volumes are reduced, however, separation of water and octanol prior to measurement and detection in small volumes of octanol phase are especially challenging. In this work, we reduce the receiver volume of octanol-water partitioning measurements from current practice by six-orders-of-magnitude, to the femtoliter scale, by using a single octanol-filled reversed-phase, octadecylsilane-modified (C18-silica) chromatographic particle as a collector. The fluid-handling challenges of working in such small volumes are circumvented by eliminating postequilibration phase separation. Partitioning is measured in situ within the pore-confined octanol phase using confocal Raman microscopy, which is capable of detecting and quantifying a wide variety of molecular structures. Equilibration times are fast (less than a minute) because molecular diffusion is efficient over distance scales of micrometers. The demonstrated amount of analyte needed to carry out a measurement is very small, less than 50 fmol, which would be a useful attribute for drug screening applications or testing of small quantities of environmentally sensitive compounds. The method is tested for measurements of pH-dependent octanol-water partitioning of naphthoic acid, and the results are compared to both traditional shake-flask measurements and sorption onto C18-modified silica without octanol present within the pores.

  8. Clinical evaluation of the reproducibility of volume measurements of pulmonary nodules

    NASA Astrophysics Data System (ADS)

    Wormanns, Dag; Kohl, Gerhard; Klotz, Ernst; Heindel, Walter; Diederich, Stefan

    2002-05-01

    High reproducibility of volumetric measurements is an important prerequisite for follow-up of small lung nodules in order to differentiate malignant from benign lesions in a lung cancer screening setting. This study was aimed to evaluate the measurement reproducibility of a new software tool for pulmonary nodule volumetry. In an ongoing study, 147 pulmonary nodules (size 1.6-17.5 mm) were examined with low-dose multidetector CT (Siemens Somatom Volume Zoom, 120 kVp, 20 mAs, detector collimation 4x1 mm, normalized pitch 1.75, slice thickness 1.25 mm, reconstruction increment 0.8 mm). Two consecutive low-dose scans covering the whole lung volume were performed within a few minutes. Between both scans, patients were asked to leave the CT scanner, and the second scan was planned independently from the first one. For all visually detected pulmonary nodules with a diameter <20 mm nodule volume was determined on both scans using a software prototype containing segmentation and volumetry algorithms. Results from both scans were compared. Nodule volume differences were determined as difference between the first and second measurement and ranged from 169 to 87%. The performance of the diagnostic test was measured using ROC analysis. For the detection of a volume doubling the area under curve (Az) was 0.98, for a growth of 50% the Az was 0.89. Further refinement of the segmentation algorithm should lead to more consistent measurements in ill-defined nodules. In conclusion, volumetric measurement of pulmonary nodules in multislice CT data sets is a reliable tool for the detection of growth in small pulmonary nodules.

  9. Small-volume multiparametric electrochemical detection at low cost polymeric devices featuring nanoelectrodes

    NASA Astrophysics Data System (ADS)

    Kitsara, Maria; Cirera, Josep Maria; Aller-Pellitero, Miguel; Sabaté, Neus; Punter, Jaume; Colomer-Farrarons, Jordi; Miribel-Català, Pere; del Campo, F. Javier

    2015-06-01

    The development of a low-cost multiparametric platform for enzymatic electrochemical biosensing that can be integrated in a disposable, energy autonomous analytical device is the target of the current work. We propose a technology to fabricate nano-electrodes and ultimately biosensors on flexible polymeric-based substrates (cyclo olefin polymer, and polyimide) using standard microfabrication (step and repeat lithography and lift-off) and rapid prototyping techniques (blade cutting). Our target is towards the fabrication of a miniaturized prototype that can work with small sample volumes in the range of 5-10μL without the need for external pumps for sample loading and handling. This device can be used for the simultaneous detection of metabolites such as glucose, cholesterol and triglycerides for the early diagnosis of diabetes.

  10. Detection of Micrococcus luteus biofilm formation in microfluidic environments by pH measurement using an ion-sensitive field-effect transistor.

    PubMed

    Matsuura, Koji; Asano, Yuka; Yamada, Akira; Naruse, Keiji

    2013-02-18

    Biofilm formation in microfluidic channels is difficult to detect because sampling volumes are too small for conventional turbidity measurements. To detect biofilm formation, we used an ion-sensitive field-effect transistor (ISFET) measurement system to measure pH changes in small volumes of bacterial suspension. Cells of Micrococcus luteus (M. luteus) were cultured in polystyrene (PS) microtubes and polymethylmethacrylate (PMMA)-based microfluidic channels laminated with polyvinylidene chloride. In microtubes, concentrations of bacteria and pH in the suspension were analyzed by measuring turbidity and using an ISFET sensor, respectively. In microfluidic channels containing 20 μL of bacterial suspension, we measured pH changes using the ISFET sensor and monitored biofilm formation using a microscope. We detected acidification and alkalinization phases of M. luteus from the ISFET sensor signals in both microtubes and microfluidic channels. In the alkalinization phase, after 2 day culture, dense biofilm formation was observed at the bottom of the microfluidic channels. In this study, we used an ISFET sensor to detect biofilm formation in clinical and industrial microfluidic environments by detecting alkalinization of the culture medium. 

  11. Label-free and ultrasensitive fluorescence detection of cocaine based on a strategy that utilizes DNA-templated silver nanoclusters and the nicking endonuclease-assisted signal amplification method.

    PubMed

    Zhang, Kai; Wang, Ke; Zhu, Xue; Zhang, Jue; Xu, Lan; Huang, Biao; Xie, Minhao

    2014-01-07

    A general and reliable strategy for the detection of cocaine was proposed utilizing DNA-templated silver nanoclusters as signal indicators and the nicking endonuclease-assisted signal amplification method. This strategy can detect cocaine specifically with a detection limit as low as 2 nM by using a small volume of 5 μL.

  12. Concentration methods for high-resolution THz spectroscopy of nucleic-acid biomolecules and crystals

    NASA Astrophysics Data System (ADS)

    Brown, E. R.; Zhang, W.; Mendoza, E. A.; Kuznetsova, Y.; Brueck, S. R. J.; Rahman, M.; Norton, M. L.

    2012-03-01

    Biomolecules can exhibit low-lying vibrational modes in the THz region which are detectable in transmission given a strong molecular dipole moment and optical depth, and a spectrometer of adequate sensitivity. The nucleic acids are particularly interesting because of applications such as label-free gene assay, bio-agent detection, etc. However for nucleic acids, sample preparation and THz coupling are of paramount importance because of the strong absorption by liquid water and the small concentration of molecules present in physiological solutions. Concentration methods become necessary to make the THz vibrational modes detectable, either by concentrating the nucleic-acid sample itself in a small volume but large area, or by concentrating the THz radiation down to the volume of the sample. This paper summarizes one type of the first method: nanofluidic channel arrays for biological nucleic acids; and two types of the second method: (1) a circular-waveguide pinhole, and (2) a circular-waveguide, conical-horn coupling structure, both for DNA crystals. The first method has been demonstrated on a very short artificial nucleic acid [small-interfering (si) RNA (17-to-25 bp)] and a much longer, biological molecule [Lambda-phage DNA (48.5 kbp)]. The second method has been demonstrated on small (~100 micron) single crystals of DNA grown by the sitting-drop method.

  13. Sensitive Detection of Small Particles in Fluids Using Optical Fiber Tip with Dielectrophoresis

    PubMed Central

    Tai, Yi-Hsin; Chang, Dao-Ming; Pan, Ming-Yang; Huang, Ding-Wei; Wei, Pei-Kuen

    2016-01-01

    This work presents using a tapered fiber tip coated with thin metallic film to detect small particles in water with high sensitivity. When an AC voltage applied to the Ti/Al coated fiber tip and indium tin oxide (ITO) substrate, a gradient electric field at the fiber tip induced attractive/repulsive force to suspended small particles due to the frequency-dependent dielectrophoresis (DEP) effect. Such DEP force greatly enhanced the concentration of the small particles near the tip. The increase of the local concentration also increased the scattering of surface plasmon wave near the fiber tip. Combined both DEP effect and scattering optical near-field, we show the detection limit of the concentration for 1.36 μm polystyrene beads can be down to 1 particle/mL. The detection limit of the Escherichia coli (E. coli) bacteria was 20 CFU/mL. The fiber tip sensor takes advantages of ultrasmall volume, label-free and simple detection system. PMID:26927128

  14. Fundamentals and practice for ultrasensitive laser-induced fluorescence detection in microanalytical systems.

    PubMed

    Johnson, Mitchell E; Landers, James P

    2004-11-01

    Laser-induced fluorescence is an extremely sensitive method for detection in chemical separations. In addition, it is well-suited to detection in small volumes, and as such is widely used for capillary electrophoresis and microchip-based separations. This review explores the detailed instrumental conditions required for sub-zeptomole, sub-picomolar detection limits. The key to achieving the best sensitivity is to use an excitation and emission volume that is matched to the separation system and that, simultaneously, will keep scattering and luminescence background to a minimum. We discuss how this is accomplished with confocal detection, 90 degrees on-capillary detection, and sheath-flow detection. It is shown that each of these methods have their advantages and disadvantages, but that all can be used to produce extremely sensitive detectors for capillary- or microchip-based separations. Analysis of these capabilities allows prediction of the optimal means of achieving ultrasensitive detection on microchips.

  15. Conflicts between sensory performance and locomotion in weakly electric fish

    NASA Astrophysics Data System (ADS)

    Maciver, Malcolm; Shirgaonkar, Anup; Patankar, Neelesh

    2008-11-01

    The knifefish Apteronotus albifrons hunts for small water insects at night using a self-generated electric field to perceive its world. Using this unique sensory adaptation, the fish senses prey that are near its body with a detection volume that approximates a cylinder that has a length ten times its radius, similar to the fish's elongated body plan. If the fish swims straight, then the back portion of the actively generated detection volume is scanning fluid already scanned by the front portion, but the energy expended to overcome drag is minimized. If it swims with the body pitched, then the rate of volume scanned for prey is increased, but the energy needed to overcome body drag is also increased. In this work we examine the compromise the fish makes between minimizing energy in overcoming drag and maximizing scan rate. We use computational fluid dynamics simulations to assess the impact of changes in body pitch angle on drag, and computational neuroscience simulations to assess the shape and size of the prey detection volume and how body angle changes the scan volume rate.

  16. Integrated hollow microneedle-optofluidic biosensor for therapeutic drug monitoring in sub-nanoliter volumes

    NASA Astrophysics Data System (ADS)

    Ranamukhaarachchi, Sahan A.; Padeste, Celestino; Dübner, Matthias; Häfeli, Urs O.; Stoeber, Boris; Cadarso, Victor J.

    2016-07-01

    Therapeutic drug monitoring (TDM) typically requires painful blood drawn from patients. We propose a painless and minimally-invasive alternative for TDM using hollow microneedles suitable to extract extremely small volumes (<1 nL) of interstitial fluid to measure drug concentrations. The inner lumen of a microneedle is functionalized to be used as a micro-reactor during sample collection to trap and bind target drug candidates during extraction, without requirements of sample transfer. An optofluidic device is integrated with this microneedle to rapidly quantify drug analytes with high sensitivity using a straightforward absorbance scheme. Vancomycin is currently detected by using volumes ranging between 50-100 μL with a limit of detection (LoD) of 1.35 μM. The proposed microneedle-optofluidic biosensor can detect vancomycin with a sample volume of 0.6 nL and a LoD of <100 nM, validating this painless point of care system with significant potential to reduce healthcare costs and patients suffering.

  17. Integrated hollow microneedle-optofluidic biosensor for therapeutic drug monitoring in sub-nanoliter volumes

    PubMed Central

    Ranamukhaarachchi, Sahan A.; Padeste, Celestino; Dübner, Matthias; Häfeli, Urs O.; Stoeber, Boris; Cadarso, Victor J.

    2016-01-01

    Therapeutic drug monitoring (TDM) typically requires painful blood drawn from patients. We propose a painless and minimally-invasive alternative for TDM using hollow microneedles suitable to extract extremely small volumes (<1 nL) of interstitial fluid to measure drug concentrations. The inner lumen of a microneedle is functionalized to be used as a micro-reactor during sample collection to trap and bind target drug candidates during extraction, without requirements of sample transfer. An optofluidic device is integrated with this microneedle to rapidly quantify drug analytes with high sensitivity using a straightforward absorbance scheme. Vancomycin is currently detected by using volumes ranging between 50–100 μL with a limit of detection (LoD) of 1.35 μM. The proposed microneedle-optofluidic biosensor can detect vancomycin with a sample volume of 0.6 nL and a LoD of <100 nM, validating this painless point of care system with significant potential to reduce healthcare costs and patients suffering. PMID:27380889

  18. Suitability of frequency modulated thermal wave imaging for skin cancer detection-A theoretical prediction.

    PubMed

    Bhowmik, Arka; Repaka, Ramjee; Mulaveesala, Ravibabu; Mishra, Subhash C

    2015-07-01

    A theoretical study on the quantification of surface thermal response of cancerous human skin using the frequency modulated thermal wave imaging (FMTWI) technique has been presented in this article. For the first time, the use of the FMTWI technique for the detection and the differentiation of skin cancer has been demonstrated in this article. A three dimensional multilayered skin has been considered with the counter-current blood vessels in individual skin layers along with different stages of cancerous lesions based on geometrical, thermal and physical parameters available in the literature. Transient surface thermal responses of melanoma during FMTWI of skin cancer have been obtained by integrating the heat transfer model for biological tissue along with the flow model for blood vessels. It has been observed from the numerical results that, flow of blood in the subsurface region leads to a substantial alteration on the surface thermal response of the human skin. The alteration due to blood flow further causes a reduction in the performance of the thermal imaging technique during the thermal evaluation of earliest melanoma stages (small volume) compared to relatively large volume. Based on theoretical study, it has been predicted that the method is suitable for detection and differentiation of melanoma with comparatively large volume than the earliest development stages (small volume). The study has also performed phase based image analysis of the raw thermograms to resolve the different stages of melanoma volume. The phase images have been found to be clearly individuate the different development stages of melanoma compared to raw thermograms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Optimization of the performance of the polymerase chain reaction in silicon-based microstructures.

    PubMed Central

    Taylor, T B; Winn-Deen, E S; Picozza, E; Woudenberg, T M; Albin, M

    1997-01-01

    We have demonstrated the ability to perform real-time homogeneous, sequence specific detection of PCR products in silicon microstructures. Optimal design/ processing result in equivalent performance (yield and specificity) for high surface-to-volume silicon structures as compared to larger volume reactions in polypropylene tubes. Amplifications in volumes as small as 0.5 microl and thermal cycling times reduced as much as 5-fold from that of conventional systems have been demonstrated for the microstructures. PMID:9224619

  20. Apparatus and process for microbial detection and enumeration

    NASA Technical Reports Server (NTRS)

    Wilkins, J. R.; Grana, D. (Inventor)

    1982-01-01

    An apparatus and process for detecting and enumerating specific microorganisms from large volume samples containing small numbers of the microorganisms is presented. The large volume samples are filtered through a membrane filter to concentrate the microorganisms. The filter is positioned between two absorbent pads and previously moistened with a growth medium for the microorganisms. A pair of electrodes are disposed against the filter and the pad electrode filter assembly is retained within a petri dish by retainer ring. The cover is positioned on base of petri dish and sealed at the edges by a parafilm seal prior to being electrically connected via connectors to a strip chart recorder for detecting and enumerating the microorganisms collected on filter.

  1. Size distribution and growth rate of crystal nuclei near critical undercooling in small volumes

    NASA Astrophysics Data System (ADS)

    Kožíšek, Z.; Demo, P.

    2017-11-01

    Kinetic equations are numerically solved within standard nucleation model to determine the size distribution of nuclei in small volumes near critical undercooling. Critical undercooling, when first nuclei are detected within the system, depends on the droplet volume. The size distribution of nuclei reaches the stationary value after some time delay and decreases with nucleus size. Only a certain maximum size of nuclei is reached in small volumes near critical undercooling. As a model system, we selected recently studied nucleation in Ni droplet [J. Bokeloh et al., Phys. Rev. Let. 107 (2011) 145701] due to available experimental and simulation data. However, using these data for sample masses from 23 μg up to 63 mg (corresponding to experiments) leads to the size distribution of nuclei, when no critical nuclei in Ni droplet are formed (the number of critical nuclei < 1). If one takes into account the size dependence of the interfacial energy, the size distribution of nuclei increases to reasonable values. In lower volumes (V ≤ 10-9 m3) nucleus size reaches some maximum extreme size, which quickly increases with undercooling. Supercritical clusters continue their growth only if the number of critical nuclei is sufficiently high.

  2. Real-Time Microfluidic Blood-Counting System for PET and SPECT Preclinical Pharmacokinetic Studies.

    PubMed

    Convert, Laurence; Lebel, Réjean; Gascon, Suzanne; Fontaine, Réjean; Pratte, Jean-François; Charette, Paul; Aimez, Vincent; Lecomte, Roger

    2016-09-01

    Small-animal nuclear imaging modalities have become essential tools in the development process of new drugs, diagnostic procedures, and therapies. Quantification of metabolic or physiologic parameters is based on pharmacokinetic modeling of radiotracer biodistribution, which requires the blood input function in addition to tissue images. Such measurements are challenging in small animals because of their small blood volume. In this work, we propose a microfluidic counting system to monitor rodent blood radioactivity in real time, with high efficiency and small detection volume (∼1 μL). A microfluidic channel is built directly above unpackaged p-i-n photodiodes to detect β-particles with maximum efficiency. The device is embedded in a compact system comprising dedicated electronics, shielding, and pumping unit controlled by custom firmware to enable measurements next to small-animal scanners. Data corrections required to use the input function in pharmacokinetic models were established using calibrated solutions of the most common PET and SPECT radiotracers. Sensitivity, dead time, propagation delay, dispersion, background sensitivity, and the effect of sample temperature were characterized. The system was tested for pharmacokinetic studies in mice by quantifying myocardial perfusion and oxygen consumption with (11)C-acetate (PET) and by measuring the arterial input function using (99m)TcO4 (-) (SPECT). Sensitivity for PET isotopes reached 20%-47%, a 2- to 10-fold improvement relative to conventional catheter-based geometries. Furthermore, the system detected (99m)Tc-based SPECT tracers with an efficiency of 4%, an outcome not possible through a catheter. Correction for dead time was found to be unnecessary for small-animal experiments, whereas propagation delay and dispersion within the microfluidic channel were accurately corrected. Background activity and sample temperature were shown to have no influence on measurements. Finally, the system was successfully used in animal studies. A fully operational microfluidic blood-counting system for preclinical pharmacokinetic studies was developed. Microfluidics enabled reliable and high-efficiency measurement of the blood concentration of most common PET and SPECT radiotracers with high temporal resolution in small blood volume. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  3. PCR-based detection of Toxoplasma gondii DNA in blood and ocular samples for diagnosis of ocular toxoplasmosis.

    PubMed

    Bourdin, C; Busse, A; Kouamou, E; Touafek, F; Bodaghi, B; Le Hoang, P; Mazier, D; Paris, L; Fekkar, A

    2014-11-01

    PCR detection of Toxoplasma gondii in blood has been suggested as a possibly efficient method for the diagnosis of ocular toxoplasmosis (OT) and furthermore for genotyping the strain involved in the disease. To assess this hypothesis, we performed PCR with 121 peripheral blood samples from 104 patients showing clinical and/or biological evidence of ocular toxoplasmosis and from 284 (258 patients) controls. We tested 2 different extraction protocols, using either 200 μl (small volume) or 2 ml (large volume) of whole blood. Sensitivity was poor, i.e., 4.1% and 25% for the small- and large-volume extractions, respectively. In comparison, PCR with ocular samples yielded 35.9% sensitivity, while immunoblotting and calculation of the Goldmann-Witmer coefficient yielded 47.6% and 72.3% sensitivities, respectively. Performing these three methods together provided 89.4% sensitivity. Whatever the origin of the sample (ocular or blood), PCR provided higher sensitivity for immunocompromised patients than for their immunocompetent counterparts. Consequently, PCR detection of Toxoplasma gondii in blood samples cannot currently be considered a sufficient tool for the diagnosis of OT, and ocular sampling remains necessary for the biological diagnosis of OT. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  4. Forced oscillometry track sites of airway obstruction in bronchial asthma.

    PubMed

    Hafez, Manal Refaat; Abu-Bakr, Samiha Mohamed; Mohamed, Alyaa Abdelnaser

    2015-07-01

    Spirometry is the most commonly used method for assessment of airway function in bronchial asthma but has several limitations. Forced oscillometry was developed as a patient-friendly test that requires passive cooperation of the patient breathing normally through the mouth. To compare spirometry with forced oscillometry to assess the role of forced oscillometry in the detection of the site of airway obstruction. This case-and-control study included 50 patients with known stable asthma and 50 age- and sex-matched healthy subjects. All participants underwent spirometry (ratio of force expiration volume in 1 second to forced vital capacity, percentage predicted for forced expiration volume in 1 second, percentage predicted for forced vital capacity, percentage predicted for vital capacity, and forced expiratory flow at 25-75%) and forced oscillometry (resistance at 5, 20, and 5-20 Hz). By spirometry, all patients with asthma had airway obstruction, 8% had isolated small airway obstruction, 10% had isolated large airway obstruction, and 82% had large and small airway obstruction. By forced oscillometry, 12% had normal airway resistance, 50% had isolated small airway obstruction with frequency-dependent resistance, and 38% had large and small airway obstruction with frequency-independent resistance. There was significant difference between techniques for the detection of the site of airway obstruction (P = .012). Forced oscillometry indices were negatively correlated with spirometric indices (P < .01). Forced oscillometry as an effortless test, conducted during quiet tidal breathing, and does not alter airway caliber; thus, it can detect normal airway function better than spirometry in patients with asthma. Forced oscillometry detects isolated small airway obstruction better than spirometry in bronchial asthma. Copyright © 2015 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  5. Photoacoustics of disperse systems: Below cavitation threshold

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Egerev, Sergey; Ovchinnikov, Oleg

    2012-05-24

    The paper considers photoacoustic (PA) conversion while irradiating suspensions in extra-small volume probes with laser pulses having small fluence values. Only linear and nonlinear thermooptical laser sound generation regimes were observed. Thus, good repeatability of acoustic signal parameters informative about probe content was achieved. The experiment conducted has shown how one can avoid the decrease of particles detection sensitivity for the thermooptical mode.

  6. Effects of exchanged cation on the microporosity of montmorillonite

    USGS Publications Warehouse

    Rutherford, David W.; Chiou, Cary T.; Eberl, Dennis D.

    1997-01-01

    The micropore volumes of 2 montmorillonites (SAz-1 and SWy-1), each exchanged with Ca, Na, K, Cs and tetramethylammonium (TMA) ions, were calculated from the measured vapor adsorption data of N2 and neo-hexane by use of t- and αs-plots. The corresponding surface areas of the exchanged clays were determined from Brunauer-Emmett-Teller (BET) plots of N2 adsorption data. Micropore volumes and surface areas of the samples increased with the size of exchanged cation: TMA > Cs > K > Ca > Na. The SAz-1 exchanged clays showed generally greater micropore volumes and surface areas than the corresponding SWy-1 clays. The vapor adsorption data and d(001) measurements for dry clay samples were used together to evaluate the likely locations and accessibility of clay micropores, especially the relative accessibility of their interlayer spacing. For both source clays exchanged with Na, Ca and K ions, the interlayer spacing appeared to be too small to admit nonpolar gases and the accessible micropores appeared to have dimensions greater than 5.0 Å, the limiting molecular dimension of neo-hexane. In these systems, there was a good consistency of micropore volumes detected by N2 and neo-hexane. When the clays were intercalated with relatively large cations (TMA and possibly Cs), the large layer expansion created additional microporosity, which was more readily accessible to small N2 than to relatively large neo-hexane. Hence, the micropore volume as detected by N2 was greater than that detected by neo-hexane. The micropore volumes with pore dimensions greater than 5 Å determined for clays exchanged with Na, Ca and K likely resulted from the pores on particle edges and void created by overlap regions of layers. The increase in micropore volumes with pore dimensions less than 5 Å determined for clays exchanged with TMA and possibly Cs could be caused by opening of the interlayer region by the intercalation of these large cations.

  7. Molecular diagnostics using magnetic nanobeads

    NASA Astrophysics Data System (ADS)

    Zardán Gómez de la Torre, Teresa; Strömberg, Mattias; Göransson, Jenny; Gunnarsson, Klas; Nilsson, Mats; Svedlindh, Peter; Strømme, Maria

    2010-01-01

    In this paper, we investigate the volume-amplified magnetic nanobead detection assay with respect to bead size, bead concentration and bead oligonucleotide surface coverage in order to improve the understanding of the underlying microscopic mechanisms. It has been shown that: (i) the immobilization efficiency of the beads depends on the surface coverage of oligonucleotides, (ii) by using lower amounts of probe-tagged beads, detection sensitivity can be improved and (iii) using small enough beads enables both turn-off and turn-on detection. Finally, biplex detection was demonstrated.

  8. Small volume acid reflux in gastroesophageal reflux disease patients with hiatal hernia is only detectable by pH-metry but not by multichannel intraluminal impedance.

    PubMed

    Weigt, J; Malfertheiner, P

    2013-07-01

    Until now, it is uncertain if the so-called pH-only reflux episodes that consist of a pH drop without evidence of retrograde bolus movement in multichannel intraluminal impedance (MII) represent reflux episodes or artifacts. Hiatal hernia (HH) may allow reflux of small volumes to occur that can be detected by pH-metry but not by MII. The aim was to search for a mechanism that can explain pH-only reflux, 20 patients (12 females and 8 males, median age 52 years, interquartile range [IQR]: 40.5-60.75 years) were investigated with MII-pH off PPI. Impedance and pH-metry data were analyzed separately. The differences in detection rate of acid reflux between pH-metry and MII were correlated with the presence of HH. In an in vitro experiment, MII-pH probes were flushed with citric acid in plastic tubes of different size with capillary diameter and diameters of 2.5 mm and 4.5 mm, while recording pH values and impedance. HH was present in six patients and absent in 14 patients. In patients with HH in comparison with patients with absent HH, the difference of acid reflux detection between pH-metry and MII is significantly higher (70%, IQR: 15-88% and 3.6%, IQR: 0-31%, respectively). In vitro all simulated reflux lead to a fall in pH whereas a corresponding decrease in impedance was only recognizable in the 4.5-mm plastic tubes. Acid reflux episodes in patients with HH are more frequently detected by pH-metry than by MII. Small volume reflux that does not lead to a decrease in impedance is the likely explanation for this phenomenon. © 2012 Copyright the Authors. Journal compilation © 2012, Wiley Periodicals, Inc. and the International Society for Diseases of the Esophagus.

  9. Developments in Analytical Chemistry: Acoustically Levitated Drop Reactors for Enzyme Reaction Kinetics and Single-Walled Carbon Nanotube-Based Sensors for Detection of Toxic Organic Phosphonates

    ERIC Educational Resources Information Center

    Field, Christopher Ryan

    2009-01-01

    Developments in analytical chemistry were made using acoustically levitated small volumes of liquid to study enzyme reaction kinetics and by detecting volatile organic compounds in the gas phase using single-walled carbon nanotubes. Experience gained in engineering, electronics, automation, and software development from the design and…

  10. Characterization of Large Volume CLYC Scintillators for Nuclear Security Applications

    NASA Astrophysics Data System (ADS)

    Soundara-Pandian, Lakshmi; Tower, J.; Hines, C.; O'Dougherty, P.; Glodo, J.; Shah, K.

    2017-07-01

    We report on our development of large volume Cs2LiYCl6 (CLYC) detectors for nuclear security applications. Three-inch diameter boules have been grown and 3-in right cylinders have been fabricated. Crystals containing either >95% 6Li or >99% 7Li have been grown for applications specific to thermal or fast neutron detection, respectively. We evaluated their gamma and neutron detection properties and the performance is as good as small size crystals. Gamma and neutron efficiencies were measured for large crystals and compared with smaller size crystals. With their excellent performance characteristics, and the ability to detect fast neutrons, CLYC detectors are excellent triple-mode scintillators for use in handheld and backpack instruments for nuclear security applications.

  11. Recent advances in chemiluminescence detection coupled with capillary electrophoresis and microchip capillary electrophoresis.

    PubMed

    Liu, Yuxuan; Huang, Xiangyi; Ren, Jicun

    2016-01-01

    CE is an ideal analytical method for extremely volume-limited biological microenvironments. However, the small injection volume makes it a challenge to achieve highly sensitive detection. Chemiluminescence (CL) detection is characterized by providing low background with excellent sensitivity because of requiring no light source. The coupling of CL with CE and MCE has become a powerful analytical method. So far, this method has been widely applied to chemical analysis, bioassay, drug analysis, and environment analysis. In this review, we first introduce some developments for CE-CL and MCE-CL systems, and then put the emphasis on the applications in the last 10 years. Finally, we discuss the future prospects. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Organic materials and devices for detecting ionizing radiation

    DOEpatents

    Doty, F Patrick [Livermore, CA; Chinn, Douglas A [Livermore, CA

    2007-03-06

    A .pi.-conjugated organic material for detecting ionizing radiation, and particularly for detecting low energy fission neutrons. The .pi.-conjugated materials comprise a class of organic materials whose members are intrinsic semiconducting materials. Included in this class are .pi.-conjugated polymers, polyaromatic hydrocarbon molecules, and quinolates. Because of their high resistivities (.gtoreq.10.sup.9 ohmcm), these .pi.-conjugated organic materials exhibit very low leakage currents. A device for detecting and measuring ionizing radiation can be made by applying an electric field to a layer of the .pi.-conjugated polymer material to measure electron/hole pair formation. A layer of the .pi.-conjugated polymer material can be made by conventional polymer fabrication methods and can be cast into sheets capable of covering large areas. These sheets of polymer radiation detector material can be deposited between flexible electrodes and rolled up to form a radiation detector occupying a small volume but having a large surface area. The semiconducting polymer material can be easily fabricated in layers about 10 .mu.m to 100 .mu.m thick. These thin polymer layers and their associated electrodes can be stacked to form unique multi-layer detector arrangements that occupy small volume.

  13. [Detection of intraorbital foreign material using MDCT].

    PubMed

    Hoffstetter, P; Friedrich, C; Framme, C; Hoffstetter, M; Zorger, N; Stierstorfer, K; Ross, C; Uller, W; Müller-Wille, R; Rennert, J; Jung, E M; Schreyer, A G

    2011-06-01

    To judge the possibilities of detection of orbital foreign bodies in multidetector CT (MDCT) with a focus on glass slivers. Experimental systematic measuring of Hounsfield Units (HU) of 20 different materials, containing 16 different types of glass with 4 different types of ophthalmic lenses among them. The measurements were performed using a standardized protocol with an orbita phantom being scanned with 16-slice MDCT. Using the resulting density values, the smallest detectable volume was calculated. Using this data we produced slivers of 5 different glass types in the sub-millimeter range and calculated their volume. Those micro-slivers underwent another CT scan using the same protocol as mentioned above to experimentally discern and confirm the detection limit for micro-slivers made of different materials. Glass has comparatively high density values of at least 2000 HU. The density of glasses with strong refraction is significantly higher and reaches up to 12 400 HU. We calculated a minimum detectable volume of 0.07 mm (3) for glass with a density of 2000 HU. Only glass slivers with a density higher than 8300 HU were experimentally detectable in the sub-millimeter range up to a volume as small as 0.01 mm (3). Less dense glass slivers could not be seen, even though their volume was above the theoretically calculated threshold for detection. Due to its high density of at least 2000 HU, glass is usually easily recognizable as an orbital foreign body. The detection threshold depends on the object's density and size and can be as low as 0.01 mm (3) in the case of glass with strong refraction and thus high density. The detection of glass as an orbital foreign body seems to be secure for slivers with a volume of at least 0.2 mm (3) for all types of glass. © Georg Thieme Verlag KG Stuttgart · New York.

  14. [Pulmonary cystic disease may be a rare complication to recurrent respiratory human papilloma virus infection].

    PubMed

    Laurberg, Peter Thaysen; Weinreich, Ulla M Øller

    2014-12-08

    A 19-year-old woman with a history of juvenile laryngeal papillomatosis (JLP), treated since childhood with multiple resections, was admitted with symptoms of pneumonia. A chest X-ray and CAT-scan revealed multiple lung cysts and a bronchoalveolar lavage detected human papilloma virus 11. The patient responded well to antibiotics. A body plethysmography showed small lung volumes and low diffusion capacity for carbon monoxide, but normal volume diffusion capacity divided by alveolar volume. Pulmonary cystic disease should be considered when patients with JLP have symptoms of pneumonia.

  15. Rapid method for measuring rotenone in water at piscicidal concentrations

    USGS Publications Warehouse

    Dawson, V.K.; Harman, P.D.; Schultz, D.P.; Allen, J.L.

    1983-01-01

    A high-performance liquid chromatography (HPLC) procedure that is rapid, specific, and sensitive (limit of detection <0.005 mg/liter) was developed for monitoring application and degradation rates of rotenone. For analysis, a water sample is buffered to pH 5 and injected through a Sep Pak(R) C18 disposable cartridge. The cartridge adsorbs and retains the rotenone which then can be eluted quantitatively from the cartridge with a small volume of methanol. This step effectively concentrates the sample and provides sample cleanup. The methanol extract is analyzed directly by HPLC on an MCH 10 reverse-phase column; methanol: water (75:25, volume : volume) is the mobile phase and flow rate is 1.5 ml/minute. The rotenone is detected by ultraviolet spectrophotometry at a wavelength of 295 nm.

  16. [Pulmonary function in patients with disseminated pulmonary tuberculosis].

    PubMed

    Nefedov, V B; Shergina, E A; Popova, L A

    2007-01-01

    Vital capacity (VC), forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), FEV1/VC%, PEF, MEF25%, MEF50%, MEF75%, TLS, TGV, pulmonary residual volume (PRV), Raw, Rin, Rex, DLCO-SB, DLCO-SS, PaO2, and PaCO2 were determined in 29 patients with disseminated pulmonary tuberculosis. Pulmonary dysfunction was detected in 93.1% of the patients. Changes were found in lung volumes and capacities in 65.5%, impaired bronchial patency and pulmonary gas exchange dysfunction were in 79.3 and 37.9%, respectively. The changes in pulmonary volumes and capacities appeared as increased PRV, decreased VC, FVC, and TLS, decreased and increased TGV; impaired bronchial patency presented as decreased PEF, MEF25%, MEF50%, MEF75%, and FEV1/VC% and increased Raw, Rin, and Rex; pulmonary gas exchange dysfunction manifested itself as reduced DLCO-SS and PaO2 and decreased and increased PaCO2. The observed functional changes varied from slight to significant and pronounced with a preponderance of small disorders, a lower detection rate of significant disorders, and rare detection of very pronounced ones.

  17. Simulating the water budget of a Prairie Potholes complex from LiDAR and hydrological models in North Dakota, USA

    USGS Publications Warehouse

    Huang, Shengli; Young, Claudia; Abdul-Aziz, Omar I.; Dahal, Devendra; Feng, Min; Liu, Shuguang

    2013-01-01

    Hydrological processes of the wetland complex in the Prairie Pothole Region (PPR) are difficult to model, partly due to a lack of wetland morphology data. We used Light Detection And Ranging (LiDAR) data sets to derive wetland features; we then modelled rainfall, snowfall, snowmelt, runoff, evaporation, the “fill-and-spill” mechanism, shallow groundwater loss, and the effect of wet and dry conditions. For large wetlands with a volume greater than thousands of cubic metres (e.g. about 3000 m3), the modelled water volume agreed fairly well with observations; however, it did not succeed for small wetlands (e.g. volume less than 450 m3). Despite the failure for small wetlands, the modelled water area of the wetland complex coincided well with interpretation of aerial photographs, showing a linear regression with R2 of around 0.80 and a mean average error of around 0.55 km2. The next step is to improve the water budget modelling for small wetlands.

  18. In vivo detection of small tumour lesions by multi-pinhole SPECT applying a 99mTc-labelled nanobody targeting the Epidermal Growth Factor Receptor

    PubMed Central

    Krüwel, Thomas; Nevoltris, Damien; Bode, Julia; Dullin, Christian; Baty, Daniel; Chames, Patrick; Alves, Frauke

    2016-01-01

    The detection of tumours in an early phase of tumour development in combination with the knowledge of expression of tumour markers such as epidermal growth factor receptor (EGFR) is an important prerequisite for clinical decisions. In this study we applied the anti-EGFR nanobody 99mTc-D10 for visualizing small tumour lesions with volumes below 100 mm3 by targeting EGFR in orthotopic human mammary MDA-MB-468 and MDA-MB-231 and subcutaneous human epidermoid A431 carcinoma mouse models. Use of nanobody 99mTc-D10 of a size as small as 15.5 kDa enables detection of tumours by single photon emission computed tomography (SPECT) imaging already 45 min post intravenous administration with high tumour uptake (>3% ID/g) in small MDA-MB-468 and A431 tumours, with tumour volumes of 52.5 mm3 ± 21.2 and 26.6 mm3 ± 16.7, respectively. Fast blood clearance with a serum half-life of 4.9 min resulted in high in vivo contrast and ex vivo tumour to blood and tissue ratios. In contrast, no accumulation of 99mTc-D10 in MDA-MB-231 tumours characterized by a very low expression of EGFR was observed. Here we present specific and high contrast in vivo visualization of small human tumours overexpressing EGFR by preclinical multi-pinhole SPECT shortly after administration of anti-EGFR nanobody 99mTc-D10. PMID:26912069

  19. Photoinduced Electron Transfer Based Ion Sensing within an Optical Fiber

    PubMed Central

    Englich, Florian V.; Foo, Tze Cheung; Richardson, Andrew C.; Ebendorff-Heidepriem, Heike; Sumby, Christopher J.; Monro, Tanya M.

    2011-01-01

    We combine suspended-core microstructured optical fibers with the photoinduced electron transfer (PET) effect to demonstrate a new type of fluorescent optical fiber-dip sensing platform for small volume ion detection. A sensor design based on a simple model PET-fluoroionophore system and small core microstructured optical fiber capable of detecting sodium ions is demonstrated. The performance of the dip sensor operating in a high sodium concentration regime (925 ppm Na+) and for lower sodium concentration environments (18.4 ppm Na+) is explored and future approaches to improving the sensor’s signal stability, sensitivity and selectivity are discussed. PMID:22163712

  20. Automated gas chromatography

    DOEpatents

    Mowry, C.D.; Blair, D.S.; Rodacy, P.J.; Reber, S.D.

    1999-07-13

    An apparatus and process for the continuous, near real-time monitoring of low-level concentrations of organic compounds in a liquid, and, more particularly, a water stream. A small liquid volume of flow from a liquid process stream containing organic compounds is diverted by an automated process to a heated vaporization capillary where the liquid volume is vaporized to a gas that flows to an automated gas chromatograph separation column to chromatographically separate the organic compounds. Organic compounds are detected and the information transmitted to a control system for use in process control. Concentrations of organic compounds less than one part per million are detected in less than one minute. 7 figs.

  1. Automated gas chromatography

    DOEpatents

    Mowry, Curtis D.; Blair, Dianna S.; Rodacy, Philip J.; Reber, Stephen D.

    1999-01-01

    An apparatus and process for the continuous, near real-time monitoring of low-level concentrations of organic compounds in a liquid, and, more particularly, a water stream. A small liquid volume of flow from a liquid process stream containing organic compounds is diverted by an automated process to a heated vaporization capillary where the liquid volume is vaporized to a gas that flows to an automated gas chromatograph separation column to chromatographically separate the organic compounds. Organic compounds are detected and the information transmitted to a control system for use in process control. Concentrations of organic compounds less than one part per million are detected in less than one minute.

  2. Bismuth-Based, Disposable Sensor for the Detection of Hydrogen Sulfide Gas.

    PubMed

    Rosolina, Samuel M; Carpenter, Thomas S; Xue, Zi-Ling

    2016-02-02

    A new sensor for the detection of hydrogen sulfide (H2S) gas has been developed to replace commercial lead(II) acetate-based test papers. The new sensor is a wet, porous, paper-like substrate coated with Bi(OH)3 or its alkaline derivatives at pH 11. In contrast to the neurotoxic lead(II) acetate, bismuth is used due to its nontoxic properties, as Bi(III) has been a reagent in medications such as Pepto-Bismol. The reaction between H2S gas and the current sensor produces a visible color change from white to yellow/brown, and the sensor responds to ≥ 30 ppb H2S in a total volume of 1.35 L of gas, a typical volume of human breath. The alkaline, wet coating helps the trapping of acidic H2S gas and its reaction with Bi(III) species, forming colored Bi2S3. The sensor is suitable for testing human bad breath and is at least 2 orders of magnitude more sensitive than a commercial H2S test paper based on Pb(II)(acetate)2. The small volume of 1.35-L H2S is important, as the commercial Pb(II)(acetate)2-based paper requires large volumes of 5 ppm H2S gas. The new sensor reported here is inexpensive, disposable, safe, and user-friendly. A simple, laboratory setup for generating small volumes of ppb-ppm of H2S gas is also reported.

  3. 3D ultrasound volume stitching using phase symmetry and harris corner detection for orthopaedic applications

    NASA Astrophysics Data System (ADS)

    Dalvi, Rupin; Hacihaliloglu, Ilker; Abugharbieh, Rafeef

    2010-03-01

    Stitching of volumes obtained from three dimensional (3D) ultrasound (US) scanners improves visualization of anatomy in many clinical applications. Fast but accurate volume registration remains the key challenge in this area.We propose a volume stitching method based on efficient registration of 3D US volumes obtained from a tracked US probe. Since the volumes, after adjusting for probe motion, are coarsely registered, we obtain salient correspondence points in the central slices of these volumes. This is done by first removing artifacts in the US slices using intensity invariant local phase image processing and then applying the Harris Corner detection algorithm. Fast sub-volume registration on a small neighborhood around the points then gives fast, accurate 3D registration parameters. The method has been tested on 3D US scans of phantom and real human radius and pelvis bones and a phantom human fetus. The method has also been compared to volumetric registration, as well as feature based registration using 3D-SIFT. Quantitative results show average post-registration error of 0.33mm which is comparable to volumetric registration accuracy (0.31mm) and much better than 3D-SIFT based registration which failed to register the volumes. The proposed method was also much faster than volumetric registration (~4.5 seconds versus 83 seconds).

  4. Detecting vapour bubbles in simulations of metastable water

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    González, Miguel A.; Abascal, Jose L. F.; Valeriani, Chantal, E-mail: christoph.dellago@univie.ac.at, E-mail: cvaleriani@quim.ucm.es

    2014-11-14

    The investigation of cavitation in metastable liquids with molecular simulations requires an appropriate definition of the volume of the vapour bubble forming within the metastable liquid phase. Commonly used approaches for bubble detection exhibit two significant flaws: first, when applied to water they often identify the voids within the hydrogen bond network as bubbles thus masking the signature of emerging bubbles and, second, they lack thermodynamic consistency. Here, we present two grid-based methods, the M-method and the V-method, to detect bubbles in metastable water specifically designed to address these shortcomings. The M-method incorporates information about neighbouring grid cells to distinguishmore » between liquid- and vapour-like cells, which allows for a very sensitive detection of small bubbles and high spatial resolution of the detected bubbles. The V-method is calibrated such that its estimates for the bubble volume correspond to the average change in system volume and are thus thermodynamically consistent. Both methods are computationally inexpensive such that they can be used in molecular dynamics and Monte Carlo simulations of cavitation. We illustrate them by computing the free energy barrier and the size of the critical bubble for cavitation in water at negative pressure.« less

  5. Detection of protease and protease activity using a single nanoscrescent SERS probe

    DOEpatents

    Liu, Gang L.; Ellman, Jonathan A.; Lee, Luke P.; Chen, Fanqing Frank

    2013-01-29

    This invention pertains to the in vitro detection of proteases using a single peptide-conjugate nanocrescent surface enhanced Raman scattering (SERS) probes with at least nanomolar sensitivity. The probe enables detection of proteolytic activity in extremely small volume and at low concentration. In certain embodiments the probes comprise an indicator for the detection of an active protease, where the indicator comprises a nanocrescent attached to a peptide, where said peptide comprises a recognition site for the protease and a Raman tag attached to the peptide.

  6. Detection of protease and protease activity using a single nanocrescent SERS probe

    DOEpatents

    Liu, Gang L.; Ellman, Jonathan A.; Lee, Luke P.; Chen, Fanqing Frank

    2015-09-29

    This invention pertains to the in vitro detection of proteases using a single peptide-conjugate nanocrescent surface enhanced Raman scattering (SERS) probes with at least nanomolar sensitivity. The probe enables detection of proteolytic activity in extremely small volume and at low concentration. In certain embodiments the probes comprise an indicator for the detection of an active protease, where the indicator comprises a nanocrescent attached to a peptide, where said peptide comprises a recognition site for the protease and a Raman tag attached to the peptide.

  7. Small-volume cavity cell using hollow optical fiber for Raman scattering-based gas detection

    NASA Astrophysics Data System (ADS)

    Okita, Y.; Katagiri, T.; Matsuura, Y.

    2011-03-01

    The highly sensitive Raman cell based on the hollow optical fiber that is suitable for the real-time breath analysis is reported. Hollow optical fiber with inner coating of silver is used as a gas cell and a Stokes light collector. A very small cell whose volume is only 0.4 ml or less enables fast response and real-time measurement of trace gases. To increase the sensitivity the cell is arranged in a cavity which includes of a long-pass filter and a high reflective mirror. The sensitivity of the cavity cell is more than two times higher than that of the cell without cavity.

  8. Whispering gallery mode resonators for rapid label-free biosensing in small volume droplets.

    PubMed

    Wildgen, Sarah M; Dunn, Robert C

    2015-03-23

    Rapid biosensing requires fast mass transport of the analyte to the surface of the sensing element. To optimize analysis times, both mass transport in solution and the geometry and size of the sensing element need to be considered. Small dielectric spheres, tens of microns in diameter, can act as label-free biosensors using whispering gallery mode (WGM) resonances. WGM resonances are sensitive to the effective refractive index, which changes upon analyte binding to recognition sites on functionalized resonators. The spherical geometry and tens of microns diameter of these resonators provides an efficient target for sensing while their compact size enables detection in limited volumes. Here, we explore conditions leading to rapid analyte detection using WGM resonators as label-free sensors in 10 μL sample droplets. Droplet evaporation leads to potentially useful convective mixing, but also limits the time over which analysis can be completed. We show that active droplet mixing combined with initial binding rate measurements is required for accurate nanomolar protein quantification within the first minute following injection.

  9. F.I.D.O. Focused Integration for Debris Observation

    NASA Astrophysics Data System (ADS)

    Ploschnitznig, J.

    2013-09-01

    The fact that satellites play a growing role in our day-to-day live, contributes to the overall assessment that these assets must be protected. As more and more objects enter space and begin to clutter this apparently endless vacuum, we begin to realize that these objects and associated debris become a potential and recurring threat. The space surveillance community routinely attempts to catalog debris through broad area search collection profiles, hoping to detect and track smaller and smaller objects. There are technical limitations to each collection system, we propose there may be new ways to increase the detection capability, effectively "Teaching an old dog (FIDO), new tricks." Far too often, we are justly criticized for never "stepping out of the box". The philosophy of "if it's not broke, don't fix it" works great if you assume that we are not broke. The assumption that in order to "Find" new space junk we need to increase our surveillance windows and try to cover as much space as possible may be appropriate for Missile Defense, but inappropriate for finding small space debris. Currently, our Phased Array Early Warning Systems support this yearly search program to try to acquire and track space small debris. A phased array can electronically scan the horizons very quickly, but the radar does have limitations. There is a closed-loop resource management equation that must be satisfied. By increasing search volume, we effectively reduce our instantaneous sensitivity which will directly impact our ability to find smaller and smaller space debris. Our proposal will be to focus on increasing sensitivity by reducing the search volume to statistically high probability of detection volumes in space. There are two phases to this proposal, a theoretical and empirical. Theoretical: The first phase will be to investigate the current space catalog and use existing ephemeris data on all satellites in the Space Surveillance Catalog to identify volumes of space with a high likelihood of encountering transiting satellite. Also during this phase, candidate radar systems will be characterized to determine sensitivity levels necessary to detect certain sized objects. Data integration plays a critical role in lowering the noise floor of the collection area in order to detect smaller and smaller objects. Reducing the search volume to these high probability of intercept areas will allow the use of data integration to increase the likelihood of detection of small Radar Cross Section objects. Empirical: The next phase is to employ this technique using a legacy collection system. The collection community may choose any collection system. The goal will be to demonstrate how focusing on a very specific area and employing data integration will increase the likelihood of detection of smaller objects. This will result in the creation of an Inter Range Vector (IRV), which can be handed-off to downrange collection systems for additional tracking. The goal of FIDO will be demonstrate how these legacy systems can be better employed to help find smaller and smaller debris.

  10. A novel device for quantitative measurement of chloride concentration by fluorescence indicator

    NASA Astrophysics Data System (ADS)

    Wang, Junsheng; Wu, Xudong; Chon, Chanhee; Gonska, Tanja; Li, Dongqing

    2012-02-01

    Cystic fibrosis (CF) is a life-threatening genetic disease. At present, the common method for diagnosis of CF is to detect the chloride concentration in sweat using ion-selective electrodes. However, the current sweat testing methods require a relatively large quantity of sweat sample, at least 25 µL, which is very difficult to obtain, especially for newborns. This paper presents a new method and a new device for rapid detection of the chloride concentration from a small volume of solution. In this method, the chloride concentration is determined quantitatively by the fluorescence intensity of MQAE, a chloride ion fluorescent indicator. In this device, the sample is carried by a small piece of filter paper on a cover glass exposed to an UV LED light source. The resulting fluorescent signals are detected by a Si photodiode. Data acquisition and processing are accomplished by LabVIEW software in a PDA. Based on the Stern-Volmer relationship, the effects of different parameters on the fluorescence intensity were analyzed. The observed significant difference between 40 and 60 mM (the borderline of chloride concentration for CF) is discussed in this paper. The results show that detection can be completed within 10 s. The minimum detectable volume of the chloride solution is 1 μL. The novel method and the device are of great potential for CF diagnosis.

  11. Comparison of computed radiography and conventional radiography in detection of small volume pneumoperitoneum.

    PubMed

    Marolf, Angela; Blaik, Margaret; Ackerman, Norman; Watson, Elizabeth; Gibson, Nicole; Thompson, Margret

    2008-01-01

    The role of digital imaging is increasing as these systems are becoming more affordable and accessible. Advantages of computed radiography compared with conventional film/screen combinations include improved contrast resolution and postprocessing capabilities. Computed radiography's spatial resolution is inferior to conventional radiography; however, this limitation is considered clinically insignificant. This study prospectively compared digital imaging and conventional radiography in detecting small volume pneumoperitoneum. Twenty cadaver dogs (15-30 kg) were injected with 0.25, 0.25, and 0.5 ml for 1 ml total of air intra-abdominally, and radiographed sequentially using computed and conventional radiographic technologies. Three radiologists independently evaluated the images, and receiver operating curve (ROC) analysis compared the two imaging modalities. There was no statistical difference between computed and conventional radiography in detecting free abdominal air, but overall computed radiography was relatively more sensitive based on ROC analysis. Computed radiographic images consistently and significantly demonstrated a minimal amount of 0.5 ml of free air based on ROC analysis. However, no minimal air amount was consistently or significantly detected with conventional film. Readers were more likely to detect free air on lateral computed images than the other projections, with no significant increased sensitivity between film/screen projections. Further studies are indicated to determine the differences or lack thereof between various digital imaging systems and conventional film/screen systems.

  12. Validation of a New Small-Volume Sodium Citrate Collection Tube for Coagulation Testing in Critically Ill Patients with Coagulopathy.

    PubMed

    Adam, Elisabeth H; Zacharowski, Kai; Hintereder, Gudrun; Raimann, Florian; Meybohm, Patrick

    2018-06-01

    Blood loss due to phlebotomy leads to hospital-acquired anemia and more frequent blood transfusions that may be associated with increased risk of morbidity and mortality in critically ill patients. Multiple blood conservation strategies have been proposed in the context of patient blood management to minimize blood loss. Here, we evaluated a new small-volume sodium citrate collection tube for coagulation testing in critically ill patients. In 46 critically adult ill patients admitted to an interdisciplinary intensive care unit, we prospectively compared small-volume (1.8 mL) sodium citrate tubes with the conventional (3 mL) sodium citrate tubes. The main inclusion criterium was a proven coagulopathy (Quick < 60% and/or aPTT > 40 second) due to anticoagulation therapy or perioperative coagulopathy. In total, 92 coagulation analyses were obtained. Linear correlation analysis detected a positive relationship for 7 coagulation parameters (Prothrombin Time, r = 0.987; INR, r = 0.985; activated Partial Thromboplastin Time, r = 0.967; Thrombin Clotting Time, r = 0.969; Fibrinogen, r = 0.986; Antithrombin, r = 0.988; DDimer, r = 0.969). Bland-Altman analyses revealed an absolute mean of differences of almost zero. Ninety-five percent of data were within two standard deviations of the mean difference suggesting interchangeability. As systematic deviations between measured parameters of the two tubes were very unlikely, test results of small-volume (1.8 mL) sodium citrate tubes were equal to conventional (3 mL) sodium citrate tubes and can be considered interchangeable. Small-volume sodium citrate tubes reduced unnecessary diagnostic-related blood loss by about 40% and, therefore, should be the new standard of care for routine coagulation analysis in critically ill patients.

  13. Mapping the MRI voxel volume in which thermal noise matches physiological noise--implications for fMRI.

    PubMed

    Bodurka, J; Ye, F; Petridou, N; Murphy, K; Bandettini, P A

    2007-01-15

    This work addresses the choice of the imaging voxel volume in blood oxygen level dependent (BOLD) functional magnetic resonance imaging (fMRI). Noise of physiological origin that is present in the voxel time course is a prohibitive factor in the detection of small activation-induced BOLD signal changes. If the physiological noise contribution dominates over the temporal fluctuation contribution in the imaging voxel, further increases in the voxel signal-to-noise ratio (SNR) will have diminished corresponding increases in temporal signal-to-noise (TSNR), resulting in reduced corresponding increases in the ability to detect activation induced signal changes. On the other hand, if the thermal and system noise dominate (suggesting a relatively low SNR) further decreases in SNR can prohibit detection of activation-induced signal changes. Here we have proposed and called the "suggested" voxel volume for fMRI the volume where thermal plus system-related and physiological noise variances are equal. Based on this condition we have created maps of fMRI suggested voxel volume from our experimental data at 3T, since this value will spatially vary depending on the contribution of physiologic noise in each voxel. Based on our fast EPI segmentation technique we have found that for gray matter (GM), white matter (WM), and cerebral spinal fluid (CSF) brain compartments the mean suggested cubical voxel volume is: (1.8 mm)3, (2.1 mm)3 and (1.4 mm)3, respectively. Serendipitously, (1.8 mm)3 cubical voxel volume for GM approximately matches the cortical thickness, thus optimizing BOLD contrast by minimizing partial volume averaging. The introduced suggested fMRI voxel volume can be a useful parameter for choice of imaging volume for functional studies.

  14. Predicting treatment related imaging changes (TRICs) after radiosurgery for brain metastases using treatment dose and conformality metrics.

    PubMed

    Taylor, B Frazier; Knisely, Jonathan P; Qian, Jack M; Yu, James B; Chiang, Veronica L

    2016-01-01

    Treatment-related imaging changes (TRICs) after stereotactic radiosurgery (SRS) involves the benign transient enlargement of radiographic lesions after treatment. Identifying the radiation dose volumes and conformality metrics associated with TRICs for different post-treatment periods would be helpful and improve clinical decision making. 367 metastases in 113 patients were treated using Gamma Knife SRS between 1/1/2007-12/31/2009. Each metastasis was measured at each imaging follow-up to detect TRICs (defined as ≥ 20% increase in volume). Fluctuations in small volume lesions (less than 108 mm 3 ) were ignored given widely variable conformity indices (CI) for small volumes. The Karolinska Adverse Radiation Effect (KARE) factor, Paddick's CI, Shaw's CI, tumor volume (TV), 10 Gy (V10) and 12 Gy (V12) volumes, and prescription isodose volume (PIV) were calculated. From 0-6 months, all measures correlated with the incidence of TRICs (p<.001), except KARE, which was inversely correlated. During the 6-12 month period all measures except KARE were still correlated. Beyond 12 months, no correlation was found between any of the measures and the development of TRICs. All metrics except KARE were associated with TRICs from 0-12 months only. Additional patient and treatment factors may become dominant at greater times after SRS.

  15. Use of a capillary electrophoresis instrument with laser-induced fluorescence detection for DNA quantitation. Comparison of YO-PRO-1 and PicoGreen assays.

    PubMed

    Guillo, Christelle; Ferrance, Jerome P; Landers, James P

    2006-04-28

    Highly selective and sensitive assays are required for detection and quantitation of the small masses of DNA typically encountered in clinical and forensic settings. High detection sensitivity is achieved using fluorescent labeling dyes and detection techniques such as spectrofluorometers, microplate readers and cytometers. This work describes the use of a laser-induced fluorescence (LIF) detector in conjunction with a commercial capillary electrophoresis instrument for DNA quantitation. PicoGreen and YO-PRO-1, two fluorescent DNA labeling dyes, were used to assess the potential of the system for routine DNA analysis. Linearity, reproducibility, sensitivity, limits of detection and quantitation, and sample stability were examined for the two assays. The LIF detector response was found to be linear (R2 > 0.999) and reproducible (RSD < 9%) in both cases. The PicoGreen assay displayed lower limits of detection and quantitation (20 pg and 60 pg, respectively) than the YO-PRO-1 assay (60 pg and 260 pg, respectively). Although a small variation in fluorescence was observed for the DNA/dye complexes over time, quantitation was not significantly affected and the solutions were found to be relatively stable for 80 min. The advantages of the technique include a 4- to 40-fold reduction in the volume of sample required compared to traditional assays, a 2- to 20-fold reduction in the volume of reagents consumed, fast and automated analysis, and low cost (no specific instrumentation required).

  16. On-Chip Spyhole Nanoelectrospray Ionization Mass Spectrometry for Sensitive Biomarker Detection in Small Volumes

    NASA Astrophysics Data System (ADS)

    Zhong, Xiaoqin; Qiao, Liang; Stauffer, Géraldine; Liu, Baohong; Girault, Hubert H.

    2018-03-01

    A polyimide microfluidic chip with a microhole emitter (Ø 10-12 μm) created on top of a microchannel by scanning laser ablation has been designed for nanoelectrospray ionization (spyhole-nanoESI) to couple microfluidics with mass spectrometry. The spyhole-nanoESI showed higher sensitivity compared to standard ESI and microESI from the end of the microchannel. The limits of detection (LOD) for peptide with the spyhole-nanoESI MS reached 50 pM, which was 600 times lower than that with standard ESI. The present microchip emitter allows the analysis of small volumes of samples. As an example, a small cell lung cancer biomarker, neuron-specific enolase (NSE), was detected by monitoring the transition of its unique peptide with the spyhole-nanoESI MS/MS. NSE at 0.2 nM could be well identified with a signal to noise ratio (S/N) of 50, and thereby its LOD was estimated to be 12 pM. The potential application of the spyhole-nanoESI MS/MS in cancer diagnosis was further demonstrated with the successful detection of 2 nM NSE from 1 μL of human serum. Before the detection, the serum sample spiked with NSE was first depleted with immune spin column, then desalted by centrifugal filter device, and finally digested by trypsin, without any other complicated preparation steps. The concentration matched the real condition of clinical samples. In addition, the microchips can be disposable to avoid any cross contamination. The present technique provides a highly efficient way to couple microfluidics with MS, which brings additional values to various microfluidics and MS-based analysis.

  17. Real-Time Polymerase Chain Reaction for Detection of Schistosoma DNA in Small-Volume Urine Samples Reflects Focal Distribution of Urogenital Schistosomiasis in Primary School Girls in KwaZulu Natal, South Africa

    PubMed Central

    Pillay, Pavitra; Taylor, Myra; Zulu, Siphosenkosi G.; Gundersen, Svein G.; Verweij, Jaco J.; Hoekstra, Pytsje; Brienen, Eric A. T.; Kleppa, Elisabeth; Kjetland, Eyrun F.; van Lieshout, Lisette

    2014-01-01

    Schistosoma haematobium eggs and Schistosoma DNA levels were measured in urine samples from 708 girls recruited from 18 randomly sampled primary schools in South Africa. Microscopic analysis of two 10-mL urine subsamples collected on three consecutive days confirmed high day-to-day variation; 103 (14.5%) girls had positive results at all six examinations, and at least one positive sample was seen in 225 (31.8%) girls. Schistosoma-specific DNA, which was measured in a 200-μL urine subsample by using real-time polymerase chain reaction, was detected in 180 (25.4%) cases, and levels of DNA corresponded significantly with average urine egg excretion. In concordance with microscopic results, polymerase chain reaction results were significantly associated with history of gynecologic symptoms and confirmed highly focal distribution of urogenital schistosomiasis. Parasite-specific DNA detection has a sensitivity comparable to single urine microscopy and could be used as a standardized high-throughput procedure to assess distribution of urogenital schistosomiasis in relatively large study populations by using small sample volumes. PMID:24470560

  18. Focusing analytes from 50 μL into 500 pL: On-chip focusing from large sample volumes using isotachophoresis.

    PubMed

    van Kooten, Xander F; Truman-Rosentsvit, Marianna; Kaigala, Govind V; Bercovici, Moran

    2017-09-05

    The use of on-chip isotachophoresis assays for diagnostic applications is often limited by the small volumes of standard microfluidic channels. Overcoming this limitation is particularly important for detection of 'discrete' biological targets (such as bacteria) at low concentrations, where the volume of processed liquid in a standard microchannel might not contain any targets. We present a novel microfluidic chip that enables ITP focusing of target analytes from initial sample volumes of 50 μL into a concentrated zone with a volume of 500 pL, corresponding to a 100,000-fold increase in mean concentration, and a 300,000-fold increase in peak concentration. We present design considerations for limiting sample dispersion in such large-volume focusing (LVF) chips and discuss the trade-off between assay time and Joule heating, which ultimately governs the scalability of LVF designs. Finally, we demonstrate a 100-fold improvement of ITP focusing performance in the LVF chip as compared to conventional microchannels, and apply this enhancement to achieve highly sensitive detection of both molecular targets (DNA, down to 10 fM) and whole bacteria (down to 100 cfu/mL).

  19. Lacunar Infarcts, but Not Perivascular Spaces, Are Predictors of Cognitive Decline in Cerebral Small-Vessel Disease

    PubMed Central

    Trippier, Sarah; Lawrence, Andrew J.; Lambert, Christian; Zeestraten, Eva; Williams, Owen A.; Patel, Bhavini; Morris, Robin G.; Barrick, Thomas R.; MacKinnon, Andrew D.; Markus, Hugh S.

    2018-01-01

    Background and Purpose— Cerebral small-vessel disease is a major cause of cognitive impairment. Perivascular spaces (PvS) occur in small-vessel disease, but their relationship to cognitive impairment remains uncertain. One reason may be difficulty in distinguishing between lacunes and PvS. We determined the relationship between baseline PvS score and PvS volume with change in cognition over a 5-year follow-up. We compared this to the relationship between baseline lacune count and total lacune volume with cognition. In addition, we examined change in PvS volume over time. Methods— Data from the prospective SCANS study (St Georges Cognition and Neuroimaging in Stroke) of patients with symptomatic lacunar stroke and confluent leukoaraiosis were used (n=121). Multimodal magnetic resonance imaging was performed annually for 3 years and neuropsychological testing annually for 5 years. Lacunes were manually identified and distinguished from PvS. PvS were rated using a validated visual rating scale, and PvS volumes calculated using T1-weighted images. Linear mixed-effect models were used to determine the impact of PvS and lacunes on cognition. Results— Baseline PvS scores or volumes showed no association with cognitive indices. No change was detectable in PvS volumes over the 3 years. In contrast, baseline lacunes associated with all cognitive indices and predicted cognitive decline over the 5-year follow-up. Conclusions— Although a feature of small-vessel disease, PvS are not a predictor of cognitive decline, in contrast to lacunes. This study highlights the importance of carefully differentiating between lacunes and PvS in studies investigating vascular cognitive impairment. PMID:29438074

  20. Quantifying Standing Dead Tree Volume and Structural Loss with Voxelized Terrestrial Lidar Data

    NASA Astrophysics Data System (ADS)

    Popescu, S. C.; Putman, E.

    2017-12-01

    Standing dead trees (SDTs) are an important forest component and impact a variety of ecosystem processes, yet the carbon pool dynamics of SDTs are poorly constrained in terrestrial carbon cycling models. The ability to model wood decay and carbon cycling in relation to detectable changes in tree structure and volume over time would greatly improve such models. The overall objective of this study was to provide automated aboveground volume estimates of SDTs and automated procedures to detect, quantify, and characterize structural losses over time with terrestrial lidar data. The specific objectives of this study were: 1) develop an automated SDT volume estimation algorithm providing accurate volume estimates for trees scanned in dense forests; 2) develop an automated change detection methodology to accurately detect and quantify SDT structural loss between subsequent terrestrial lidar observations; and 3) characterize the structural loss rates of pine and oak SDTs in southeastern Texas. A voxel-based volume estimation algorithm, "TreeVolX", was developed and incorporates several methods designed to robustly process point clouds of varying quality levels. The algorithm operates on horizontal voxel slices by segmenting the slice into distinct branch or stem sections then applying an adaptive contour interpolation and interior filling process to create solid reconstructed tree models (RTMs). TreeVolX estimated large and small branch volume with an RMSE of 7.3% and 13.8%, respectively. A voxel-based change detection methodology was developed to accurately detect and quantify structural losses and incorporated several methods to mitigate the challenges presented by shifting tree and branch positions as SDT decay progresses. The volume and structural loss of 29 SDTs, composed of Pinus taeda and Quercus stellata, were successfully estimated using multitemporal terrestrial lidar observations over elapsed times ranging from 71 - 753 days. Pine and oak structural loss rates were characterized by estimating the amount of volumetric loss occurring in 20 equal-interval height bins of each SDT. Results showed that large pine snags exhibited more rapid structural loss in comparison to medium-sized oak snags in this study.

  1. Advances in statistics

    Treesearch

    Howard Stauffer; Nadav Nur

    2005-01-01

    The papers included in the Advances in Statistics section of the Partners in Flight (PIF) 2002 Proceedings represent a small sample of statistical topics of current importance to Partners In Flight research scientists: hierarchical modeling, estimation of detection probabilities, and Bayesian applications. Sauer et al. (this volume) examines a hierarchical model...

  2. Opportunities for bead-based multiplex assays in veterinary diagnostic laboratories

    USDA-ARS?s Scientific Manuscript database

    Bead based multiplex assays (BBMA) also referred to as Luminex, MultiAnalyte Profiling or cytometric bead array (CBA) assays, are applicable for high throughput, simultaneous detection of multiple analytes in solution (from several, up to 50-500 analytes within a single, small sample volume). Curren...

  3. Second-Trimester 3-Dimensional Placental Sonography as a Predictor of Small-for-Gestational-Age Birth Weight.

    PubMed

    Quant, Hayley S; Sammel, Mary D; Parry, Samuel; Schwartz, Nadav

    2016-08-01

    We previously reported the association between first-trimester 3-dimensional (3D) placental measurements and small-for-gestational-age (SGA) neonates. In this study, we sought to determine whether second-trimester measurements further contribute to the antenatal detection of SGA and preeclampsia. We prospectively collected 3D sonographic volume sets and uterine artery pulsatility indices of singleton pregnancies at 18 to 24 weeks. Placental volume, placental quotient (placental volume/gestational age), mean placental diameter and chorionic diameter, placental morphologic index (mean placental diameter/placental quotient), placental chorionic index (mean chorionic diameter/placental quotient), and placental growth (volume per week) were assessed and evaluated as predictors of SGA and preeclampsia as a composite and alone. Of 373 pregnancies, the composite outcome occurred in 67 (18.0%): 36 (9.7%) manifested SGA alone; 27 (7.2%) developed preeclampsia alone, and 4 (1.1%) developed both. The placental volume, placental quotient, mean placental diameter, mean chorionic diameter, and volume per week were significantly smaller, whereas the placental morphologic index and chorionic index were significantly larger in pregnancies with the composite outcome (P < .01). Further analyses revealed that the significant associations with placental parameters were limited to the SGA outcome. Each placental measure remained significantly associated with SGA after adjusting for confounders. The mean uterine artery pulsatility index was not associated with either outcome. Placental parameters were moderately predictive of SGA, with adjusted areas under the curve ranging from 0.72 to 0.76. Sensitivity for detection of SGA ranged from 32.5% to 45.0%, with positive predictive values ranging from 17.3% to 22.7%. Second-trimester 3D placental measurements can identify pregnancies at risk of SGA. However, there appears to be no significant improvement compared to those obtained in the first trimester.

  4. Small-Volume Injections: Evaluation of Volume Administration Deviation From Intended Injection Volumes.

    PubMed

    Muffly, Matthew K; Chen, Michael I; Claure, Rebecca E; Drover, David R; Efron, Bradley; Fitch, William L; Hammer, Gregory B

    2017-10-01

    In the perioperative period, anesthesiologists and postanesthesia care unit (PACU) nurses routinely prepare and administer small-volume IV injections, yet the accuracy of delivered medication volumes in this setting has not been described. In this ex vivo study, we sought to characterize the degree to which small-volume injections (≤0.5 mL) deviated from the intended injection volumes among a group of pediatric anesthesiologists and pediatric postanesthesia care unit (PACU) nurses. We hypothesized that as the intended injection volumes decreased, the deviation from those intended injection volumes would increase. Ten attending pediatric anesthesiologists and 10 pediatric PACU nurses each performed a series of 10 injections into a simulated patient IV setup. Practitioners used separate 1-mL tuberculin syringes with removable 18-gauge needles (Becton-Dickinson & Company, Franklin Lakes, NJ) to aspirate 5 different volumes (0.025, 0.05, 0.1, 0.25, and 0.5 mL) of 0.25 mM Lucifer Yellow (LY) fluorescent dye constituted in saline (Sigma Aldrich, St. Louis, MO) from a rubber-stoppered vial. Each participant then injected the specified volume of LY fluorescent dye via a 3-way stopcock into IV tubing with free-flowing 0.9% sodium chloride (10 mL/min). The injected volume of LY fluorescent dye and 0.9% sodium chloride then drained into a collection vial for laboratory analysis. Microplate fluorescence wavelength detection (Infinite M1000; Tecan, Mannedorf, Switzerland) was used to measure the fluorescence of the collected fluid. Administered injection volumes were calculated based on the fluorescence of the collected fluid using a calibration curve of known LY volumes and associated fluorescence.To determine whether deviation of the administered volumes from the intended injection volumes increased at lower injection volumes, we compared the proportional injection volume error (loge [administered volume/intended volume]) for each of the 5 injection volumes using a linear regression model. Analysis of variance was used to determine whether the absolute log proportional error differed by the intended injection volume. Interindividual and intraindividual deviation from the intended injection volume was also characterized. As the intended injection volumes decreased, the absolute log proportional injection volume error increased (analysis of variance, P < .0018). The exploratory analysis revealed no significant difference in the standard deviations of the log proportional errors for injection volumes between physicians and pediatric PACU nurses; however, the difference in absolute bias was significantly higher for nurses with a 2-sided significance of P = .03. Clinically significant dose variation occurs when injecting volumes ≤0.5 mL. Administering small volumes of medications may result in unintended medication administration errors.

  5. Multimodal MRI in cerebral small vessel disease: its relationship with cognition and sensitivity to change over time.

    PubMed

    Nitkunan, Arani; Barrick, Tom R; Charlton, Rebecca A; Clark, Chris A; Markus, Hugh S

    2008-07-01

    Cerebral small vessel disease is the most common cause of vascular dementia. Interest in using MRI parameters as surrogate markers of disease to assess therapies is increasing. In patients with symptomatic sporadic small vessel disease, we determined which MRI parameters best correlated with cognitive function on cross-sectional analysis and which changed over a period of 1 year. Thirty-five patients with lacunar stroke and leukoaraiosis were recruited. They underwent multimodal MRI (brain volume, fluid-attenuated inversion recovery lesion load, lacunar infarct number, fractional anisotropy, and mean diffusivity from diffusion tensor imaging) and neuropsychological testing. Twenty-seven agreed to reattend for repeat MRI and neuropsychology at 1 year. An executive function score correlated most strongly with diffusion tensor imaging (fractional anisotropy histogram, r=-0.640, P=0.004) and brain volume (r=0.501, P=0.034). Associations with diffusion tensor imaging were stronger than with all other MRI parameters. On multiple regression of all imaging parameters, a model that contained brain volume and fractional anisotropy, together with age, gender, and premorbid IQ, explained 74% of the variance of the executive function score (P=0.0001). Changes in mean diffusivity and fractional anisotropy were detectable over the 1-year follow-up; in contrast, no change in other MRI parameters was detectable over this time period. A multimodal MRI model explains a large proportion of the variation in executive function in cerebral small vessel disease. In particular, diffusion tensor imaging correlates best with executive function and is the most sensitive to change. This supports the use of MRI, in particular diffusion tensor imaging, as a surrogate marker in treatment trials.

  6. A SIMPLE AND FAST EXTRACTION METHOD FOR ORGANOCHLORINE PESTICIDES AND POLYCHLORINATED BIPHENYLS IN SMALL VOLUMES OF AVIAN SERUM

    EPA Science Inventory

    A solid-phase extraction (SPE) method was developed using 8 M urea to desorb and extract organochlorine pesticides (OCs) and polychlorinated biphenyls (PCBs) from avian serum for analysis by capillary gas chromatography with electron capture detection (GC-ECD). The analytes were ...

  7. Gold Nanorods as Plasmonic Sensors for Particle Diffusion.

    PubMed

    Wulf, Verena; Knoch, Fabian; Speck, Thomas; Sönnichsen, Carsten

    2016-12-01

    Plasmonic gold nanoparticles are normally used as sensor to detect analytes permanently bound to their surface. If the interaction between the analyte and the nanosensor surface is negligible, it only diffuses through the sensor's sensing volume, causing a small temporal shift of the plasmon resonance position. By using a very sensitive and fast detection scheme, we are able to detect these small fluctuations in the plasmon resonance. With the help of a theoretical model consistent with our detection geometry, we determine the analyte's diffusion coefficient. The method is verified by observing the trends upon changing diffusor size and medium viscosity, and the diffusion coefficients obtained were found to reflect reduced diffusion close to a solid interface. Our method, which we refer to as NanoPCS (for nanoscale plasmon correlation spectroscopy), is of practical importance for any application involving the diffusion of analytes close to nanoparticles.

  8. Electrical impedance tomography can rapidly detect small pneumothoraces in surfactant-depleted piglets.

    PubMed

    Bhatia, Risha; Schmölzer, Georg M; Davis, Peter G; Tingay, David G

    2012-02-01

    Diagnosis of pneumothorax relies on clinical suspicion and chest X-ray, and is often delayed. We aimed to determine whether electrical impedance tomography (EIT) can accurately identify the presence of surgically created pneumothoraces before significant changes in clinical parameters. Six anesthetized and muscle-relaxed piglets with surfactant-depleted lungs were studied. Following chest drain insertion into the right ventral chest, 10-20 ml aliquots of air were instilled into the pleural space to a maximum volume of 200 ml. The pneumothorax was drained by attaching a Heimlich valve to the chest drain. At each instillation and after draining the pneumothorax, global and regional end-expiratory intra-thoracic volumes (EEV) were measured using respiratory inductive plethysmography (RIP) and EIT concurrently with [Formula: see text], heart rate and blood pressure. A significantly greater change in both global EEV(RIP) and EEV within the right ventral quadrant was seen at all volume instillations, from as little as 10 ml, compared with all other quadrants. There was no difference in EEV within the left ventral and both dorsal quadrants. Sp(O)(2) fell below 90% at 100 ml instillation. Tachycardia occurred at 140 ml instillation. EIT identified a 60% resolution of pneumothoraces within 60 s of attachment of the Heimlich valve. EIT accurately detects very small pneumothoraces before physiological parameters change.

  9. Mesial Temporal Sclerosis: Accuracy of NeuroQuant versus Neuroradiologist.

    PubMed

    Azab, M; Carone, M; Ying, S H; Yousem, D M

    2015-08-01

    We sought to compare the accuracy of a volumetric fully automated computer assessment of hippocampal volume asymmetry versus neuroradiologists' interpretations of the temporal lobes for mesial temporal sclerosis. Detecting mesial temporal sclerosis (MTS) is important for the evaluation of patients with temporal lobe epilepsy as it often guides surgical intervention. One feature of MTS is hippocampal volume loss. Electronic medical record and researcher reports of scans of patients with proved mesial temporal sclerosis were compared with volumetric assessment with an FDA-approved software package, NeuroQuant, for detection of mesial temporal sclerosis in 63 patients. The degree of volumetric asymmetry was analyzed to determine the neuroradiologists' threshold for detecting right-left asymmetry in temporal lobe volumes. Thirty-six patients had left-lateralized MTS, 25 had right-lateralized MTS, and 2 had bilateral MTS. The estimated accuracy of the neuroradiologist was 72.6% with a κ statistic of 0.512 (95% CI, 0.315-0.710) [moderate agreement, P < 3 × 10(-6)]), whereas the estimated accuracy of NeuroQuant was 79.4% with a κ statistic of 0.588 (95% CI, 0.388-0.787) [moderate agreement, P < 2 × 10(-6)]). This discrepancy in accuracy was not statistically significant. When at least a 5%-10% volume discrepancy between temporal lobes was present, the neuroradiologists detected it 75%-80% of the time. As a stand-alone fully automated software program that can process temporal lobe volume in 5-10 minutes, NeuroQuant compares favorably with trained neuroradiologists in predicting the side of mesial temporal sclerosis. Neuroradiologists can often detect even small temporal lobe volumetric changes visually. © 2015 by American Journal of Neuroradiology.

  10. Automatic extraction and processing of small RNAs on a multi-well/multi-channel (M&M) chip.

    PubMed

    Zhong, Runtao; Flack, Kenneth; Zhong, Wenwan

    2012-12-07

    The study of the regulatory roles in small RNAs can be accelerated by techniques that permit simple, low-cost, and rapid extraction of small RNAs from a small number of cells. In order to ensure highly specific and sensitive detection, the extracted RNAs should be free of the background nucleic acids and present stably in a small volume. To meet these criteria, we designed a multi-well/multi-channel (M&M) chip to carry out automatic and selective isolation of small RNAs via solid-phase extraction (SPE), followed by reverse-transcription (RT) to convert them to the more stable cDNAs in a final volume of 2 μL. Droplets containing buffers for RNA binding, washing, and elution were trapped in microwells, which were connected by one channel, and suspended in mineral oil. The silica magnetic particles (SMPs) for SPE were moved along the channel from well to well, i.e. in between droplets, by a fixed magnet and a translation stage, allowing the nucleic acid fragments to bind to the SMPs, be washed, and then be eluted for RT reaction within 15 minutes. RNAs shorter than 63 nt were selectively enriched from cell lysates, with recovery comparable to that of a commercial kit. Physical separation of the droplets on our M&M chip allowed the usage of multiple channels for parallel processing of multiple samples. It also permitted smooth integration with on-chip RT-PCR, which simultaneously detected the target microRNA, mir-191, expressed in fewer than 10 cancer cells. Our results have demonstrated that the M&M chip device is a valuable and cost-saving platform for studying small RNA expression patterns in a limited number of cells with reasonable sample throughput.

  11. Fibre optic sensor for the detection of adulterant traces in coconut oil

    NASA Astrophysics Data System (ADS)

    Sheeba, M.; Rajesh, M.; Vallabhan, C. P. G.; Nampoori, V. P. N.; Radhakrishnan, P.

    2005-11-01

    The design and development of a fibre optic evanescent wave refractometer for the detection of trace amounts of paraffin oil and palm oil in coconut oil is presented. This sensor is based on a side-polished plastic optical fibre. At the sensing region, the cladding and a small portion of the core are removed and the fibre nicely polished. The sensing region is fabricated in such a manner that it sits perfectly within a bent mould. This bending of the sensing region enhances its sensitivity. The oil mixture of different mix ratios is introduced into the sensing region and we observed a sharp decrease in the output intensity. The observed variation in the intensity is found to be linear and the detection limit is 2% (by volume) paraffin oil/palm oil in coconut oil. The resolution of this refractometric sensor is of the order of 10-3. Since coconut oil is consumed in large volumes as edible oil in south India, this fibre optic sensor finds great relevance for the detection of adulterants such as paraffin oil or palm oil which are readily miscible in coconut oil. The advantage of this type of sensor is that it is inexpensive and easy to set up. Another attraction of the side-polished fibre is that only a very small amount of analyte is needed and its response time is only 7 s.

  12. Microfluidics-based integrated airborne pathogen detection systems

    NASA Astrophysics Data System (ADS)

    Northrup, M. Allen; Alleman-Sposito, Jennifer; Austin, Todd; Devitt, Amy; Fong, Donna; Lin, Phil; Nakao, Brian; Pourahmadi, Farzad; Vinas, Mary; Yuan, Bob

    2006-09-01

    Microfluidic Systems is focused on building microfluidic platforms that interface front-end mesofluidics to handle real world sample volumes for optimal sensitivity coupled to microfluidic circuitry to process small liquid volumes for complex reagent metering, mixing, and biochemical analysis, particularly for pathogens. MFSI is the prime contractor on two programs for the US Department of Homeland Security: BAND (Bioagent Autonomous Networked Detector) and IBADS (Instantaneous Bio-Aerosol Detection System). The goal of BAND is to develop an autonomous system for monitoring the air for known biological agents. This consists of air collection, sample lysis, sample purification, detection of DNA, RNA, and toxins, and a networked interface to report the results. For IBADS, MFSI is developing the confirmatory device which must verify the presence of a pathogen with 5 minutes of an air collector/trigger sounding an alarm. Instrument designs and biological assay results from both BAND and IBADS will be presented.

  13. Rostral cranial fossa as a site for cerebrospinal fluid drainage - volumetric studies in dog breeds of different size and morphotype.

    PubMed

    Sokołowski, Wojciech; Czubaj, Norbert; Skibniewski, Michał; Barszcz, Karolina; Kupczyńska, Marta; Kinda, Wojciech; Kiełbowicz, Zdzisław

    2018-05-18

    Hydrocephalus is a multifactorial condition, whose aetiology is not fully understood. Congenital hydrocephalus frequently occurs in small and brachycephalic dog breeds. Although it is widely accepted that the cribriform plate located in the rostral cranial fossa (RCF) is a site of cerebrospinal fluid (CSF) drainage, the RCF has not been studied extensively. Literature reports indicate that a decreased caudal cranial fossa (CCF) volume in the course of the Chiari-like malformation may obstruct CSF circulation. We hypothesised that morphological diversity among different breeds in the volume of the RCF may affect CSF circulation. The aim of the study was to carry out a volumetric analysis of the RCF and the cranial cavity and to determine the ratio between them in dog breeds of different size and morphotype. We performed computed tomography (CT) morphometric analysis of the RCF compartment by obtaining volume measurements from the transverse and reformatted sagittal and dorsal planes. The rostral cranial fossa percentage - volume of the rostral cranial fossa/volume of cranial cavity × 100 (volRCF/volCC × 100) was lower in small and brachycephalic dog breeds than in the other dogs. A reduced RCF volume was detected in small and brachycephalic dog breeds, some of which are predisposed to congenital hydrocephalus. This may lead to overcrowding of brain parenchyma in the RCF and may impede CSF circulation. Our observations may be useful for future studies focusing on the causes and new therapies to treat conditions such as hydrocephalus and syringomyelia.

  14. 75 FR 29605 - Clean Alternative Fuel Vehicle and Engine Conversions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-26

    ... Small Volume Manufacturers and Small Volume Test Groups 1. Definition of Small Volume Manufacturers, Small Volume Test Groups, and Small Volume Engine Families a. Light-Duty and Heavy-Duty Complete... and Engines 2. Test Groups, Engine Families, and Evaporative Families a. Test Groups for Light-Duty...

  15. Optics-Integrated Microfluidic Platforms for Biomolecular Analyses

    PubMed Central

    Bates, Kathleen E.; Lu, Hang

    2016-01-01

    Compared with conventional optical methods, optics implemented on microfluidic chips provide small, and often much cheaper ways to interrogate biological systems from the level of single molecules up to small model organisms. The optical probing of single molecules has been used to investigate the mechanical properties of individual biological molecules; however, multiplexing of these measurements through microfluidics and nanofluidics confers many analytical advantages. Optics-integrated microfluidic systems can significantly simplify sample processing and allow a more user-friendly experience; alignments of on-chip optical components are predetermined during fabrication and many purely optical techniques are passively controlled. Furthermore, sample loss from complicated preparation and fluid transfer steps can be virtually eliminated, a particularly important attribute for biological molecules at very low concentrations. Excellent fluid handling and high surface area/volume ratios also contribute to faster detection times for low abundance molecules in small sample volumes. Although integration of optical systems with classical microfluidic analysis techniques has been limited, microfluidics offers a ready platform for interrogation of biophysical properties. By exploiting the ease with which fluids and particles can be precisely and dynamically controlled in microfluidic devices, optical sensors capable of unique imaging modes, single molecule manipulation, and detection of minute changes in concentration of an analyte are possible. PMID:27119629

  16. Defense Small Business Innovation Research Program (SBIR). Volume 4. Defense Agencies Abstracts of Phase 1 Awards. 1990

    DTIC Science & Technology

    1990-01-01

    RI 02871 Program Manager: T. DEEGAN Contract #: Title: LF DETECTION OF AIRCRAFT Topic #: DARPA90-049 Office: ID #: 50506 TECHNICAL ABSTRACT - COMBAT...INNOVATION RESEARCH PROGRAM - PHASE I SDIO Solicitation 90.1 TORRANCE, CA 90505 Program Manager: JAMES E CRAIG Contract #: Title: NONINTRUSIVE OPTICAL

  17. Statistical Power of Psychological Research: What Have We Gained in 20 Years?

    ERIC Educational Resources Information Center

    Rossi, Joseph S.

    1990-01-01

    Calculated power for 6,155 statistical tests in 221 journal articles published in 1982 volumes of "Journal of Abnormal Psychology,""Journal of Consulting and Clinical Psychology," and "Journal of Personality and Social Psychology." Power to detect small, medium, and large effects was .17, .57, and .83, respectively. Concluded that power of…

  18. Integrating quantitative PCR and Bayesian statistics in quantifying human adenoviruses in small volumes of source water.

    PubMed

    Wu, Jianyong; Gronewold, Andrew D; Rodriguez, Roberto A; Stewart, Jill R; Sobsey, Mark D

    2014-02-01

    Rapid quantification of viral pathogens in drinking and recreational water can help reduce waterborne disease risks. For this purpose, samples in small volume (e.g. 1L) are favored because of the convenience of collection, transportation and processing. However, the results of viral analysis are often subject to uncertainty. To overcome this limitation, we propose an approach that integrates Bayesian statistics, efficient concentration methods, and quantitative PCR (qPCR) to quantify viral pathogens in water. Using this approach, we quantified human adenoviruses (HAdVs) in eighteen samples of source water collected from six drinking water treatment plants. HAdVs were found in seven samples. In the other eleven samples, HAdVs were not detected by qPCR, but might have existed based on Bayesian inference. Our integrated approach that quantifies uncertainty provides a better understanding than conventional assessments of potential risks to public health, particularly in cases when pathogens may present a threat but cannot be detected by traditional methods. © 2013 Elsevier B.V. All rights reserved.

  19. Whispering Gallery Mode Resonators for Rapid Label-Free Biosensing in Small Volume Droplets

    PubMed Central

    Wildgen, Sarah M.; Dunn, Robert C.

    2015-01-01

    Rapid biosensing requires fast mass transport of the analyte to the surface of the sensing element. To optimize analysis times, both mass transport in solution and the geometry and size of the sensing element need to be considered. Small dielectric spheres, tens of microns in diameter, can act as label-free biosensors using whispering gallery mode (WGM) resonances. WGM resonances are sensitive to the effective refractive index, which changes upon analyte binding to recognition sites on functionalized resonators. The spherical geometry and tens of microns diameter of these resonators provides an efficient target for sensing while their compact size enables detection in limited volumes. Here, we explore conditions leading to rapid analyte detection using WGM resonators as label-free sensors in 10 μL sample droplets. Droplet evaporation leads to potentially useful convective mixing, but also limits the time over which analysis can be completed. We show that active droplet mixing combined with initial binding rate measurements is required for accurate nanomolar protein quantification within the first minute following injection. PMID:25806835

  20. A high-throughput assay format for determination of nitrate reductase and nitrite reductase enzyme activities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McNally, N.; Liu, Xiang Yang; Choudary, P.V.

    1997-01-01

    The authors describe a microplate-based high-throughput procedure for rapid assay of the enzyme activities of nitrate reductase and nitrite reductase, using extremely small volumes of reagents. The new procedure offers the advantages of rapidity, small sample size-nanoliter volumes, low cost, and a dramatic increase in the throughput sample number that can be analyzed simultaneously. Additional advantages can be accessed by using microplate reader application software packages that permit assigning a group type to the wells, recording of the data on exportable data files and exercising the option of using the kinetic or endpoint reading modes. The assay can also bemore » used independently for detecting nitrite residues/contamination in environmental/food samples. 10 refs., 2 figs.« less

  1. 40 CFR Appendix 7 to Subpart A of... - Determination of the Amount of Non-Aqueous Drilling Fluid (NAF) Base Fluid From Drill Cuttings by...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... multiplying the density of the small volume NAF-cuttings discharges (ρsvd) times the volume of the small...-cuttings discharges (kg) ρsvd = density of the small volume NAF-cuttings discharges (kg/bbl) VSVD = volume of the small volume NAF-cuttings discharges (bbl) The density of the small volume NAF-cuttings...

  2. 40 CFR Appendix 7 to Subpart A of... - Determination of the Amount of Non-Aqueous Drilling Fluid (NAF) Base Fluid From Drill Cuttings by...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... multiplying the density of the small volume NAF-cuttings discharges (ρsvd) times the volume of the small...-cuttings discharges (kg) ρsvd = density of the small volume NAF-cuttings discharges (kg/bbl) VSVD = volume of the small volume NAF-cuttings discharges (bbl) The density of the small volume NAF-cuttings...

  3. 40 CFR Appendix 7 to Subpart A of... - Determination of the Amount of Non-Aqueous Drilling Fluid (NAF) Base Fluid From Drill Cuttings by...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... multiplying the density of the small volume NAF-cuttings discharges (ρsvd) times the volume of the small...-cuttings discharges (kg) ρsvd = density of the small volume NAF-cuttings discharges (kg/bbl) VSVD = volume of the small volume NAF-cuttings discharges (bbl) The density of the small volume NAF-cuttings...

  4. Improved Diffuse Fluorescence Flow Cytometer Prototype for High Sensitivity Detection of Rare Circulating Cells In Vivo

    NASA Astrophysics Data System (ADS)

    Pestana, Noah Benjamin

    Accurate quantification of circulating cell populations is important in many areas of pre-clinical and clinical biomedical research, for example, in the study of cancer metastasis or the immune response following tissue and organ transplants. Normally this is done "ex-vivo" by drawing and purifying a small volume of blood and then analyzing it with flow cytometry, hemocytometry or microfludic devices, but the sensitivity of these techniques are poor and the process of handling samples has been shown to affect cell viability and behavior. More recently "in vivo flow cytometry" (IVFC) techniques have been developed where fluorescently-labeled cells flowing in a small blood vessel in the ear or retina are analyzed, but the sensitivity is generally poor due to the small sampling volume. To address this, our group recently developed a method known as "Diffuse Fluorescence Flow Cytometry" (DFFC) that allows detection and counting of rare circulating cells with diffuse photons, offering extremely high single cell counting sensitivity. In this thesis, an improved DFFC prototype was designed and validated. The chief improvements were three-fold, i) improved optical collection efficiency, ii) improved detection electronics, and iii) development of a method to mitigate motion artifacts during in vivo measurements. In combination, these improvements yielded an overall instrument detection sensitivity better than 1 cell/mL in vivo, which is the most sensitive IVFC system reported to date. Second, development and validation of a low-cost microfluidic device reader for analysis of ocular fluids is described. We demonstrate that this device has equivalent or better sensitivity and accuracy compared a fluorescence microscope, but at an order-of-magnitude reduced cost with simplified operation. Future improvements to both instruments are also discussed.

  5. Two alternative DNA extraction methods to improve the detection of Mycobacterium-tuberculosis-complex members in cattle and red deer tissue samples.

    PubMed

    Fell, Shari; Bröckl, Stephanie; Büttner, Mathias; Rettinger, Anna; Zimmermann, Pia; Straubinger, Reinhard K

    2016-09-15

    Bovine tuberculosis (bTB), which is caused by Mycobacterium bovis and M. caprae, is a notifiable animal disease in Germany. Diagnostic procedure is based on a prescribed protocol that is published in the framework of German bTB legislation. In this protocol small sample volumes are used for DNA extraction followed by real-time PCR analyses. As mycobacteria tend to concentrate in granuloma and the infected tissue in early stages of infection does not necessarily show any visible lesions, it is likely that DNA extraction from only small tissue samples (20-40 mg) of a randomly chosen spot from the organ and following PCR testing may result in false negative results. In this study two DNA extraction methods were developed to process larger sample volumes to increase the detection sensitivity of mycobacterial DNA in animal tissue. The first extraction method is based on magnetic capture, in which specific capture oligonucleotides were utilized. These nucleotides are linked to magnetic particles and capture Mycobacterium-tuberculosis-complex (MTC) DNA released from 10 to 15 g of tissue material. In a second approach remaining sediments from the magnetic capture protocol were further processed with a less complex extraction protocol that can be used in daily routine diagnostics. A total number of 100 tissue samples from 34 cattle (n = 74) and 18 red deer (n = 26) were analyzed with the developed protocols and results were compared to the prescribed protocol. All three extraction methods yield reliable results by the real-time PCR analysis. The use of larger sample volume led to a sensitivity increase of DNA detection which was shown by the decrease of Ct-values. Furthermore five samples which were tested negative or questionable by the official extraction protocol were detected positive by real time PCR when the alternative extraction methods were used. By calculating the kappa index, the three extraction protocols resulted in a moderate (0.52; protocol 1 vs 3) to almost perfect agreement (1.00; red deer sample testing with all protocols). Both new methods yielded increased detection rates for MTC DNA detection in large sample volumes and consequently improve the official diagnostic protocol.

  6. Droplet-based magnetic bead immunoassay using microchannel-connected multiwell plates (μCHAMPs) for the detection of amyloid beta oligomers.

    PubMed

    Park, Min Cheol; Kim, Moojong; Lim, Gun Taek; Kang, Sung Min; An, Seong Soo A; Kim, Tae Song; Kang, Ji Yoon

    2016-06-21

    Multiwell plates are regularly used in analytical research and clinical diagnosis but often require laborious washing steps and large sample or reagent volumes (typically, 100 μL per well). To overcome such drawbacks in the conventional multiwell plate, we present a novel microchannel-connected multiwell plate (μCHAMP) that can be used for automated disease biomarker detection in a small sample volume by performing droplet-based magnetic bead immunoassay inside the plate. In this μCHAMP-based immunoassay platform, small volumes (30-50 μL) of aqueous-phase working droplets are stably confined within each well by the simple microchannel structure (200-300 μm in height and 0.5-1 mm in width), and magnetic beads are exclusively transported into an adjacent droplet through the oil-filled microchannels assisted by a magnet array aligned beneath and controlled by a XY-motorized stage. Using this μCHAMP-based platform, we were able to perform parallel detection of synthetic amyloid beta (Aβ) oligomers as a model analyte for the early diagnosis of Alzheimer's disease (AD). This platform easily simplified the laborious and consumptive immunoassay procedure by achieving automated parallel immunoassay (32 assays per operation in 3-well connected 96-well plate) within 1 hour and at low sample consumption (less than 10 μL per assay) with no cumbersome manual washing step. Moreover, it could detect synthetic Aβ oligomers even below 10 pg mL(-1) concentration with a calculated detection limit of ∼3 pg mL(-1). Therefore, the μCHAMP and droplet-based magnetic bead immunoassay, with the combination of XY-motorized magnet array, would be a useful platform in the diagnosis of human disease, including AD, which requires low consumption of the patient's body fluid sample and automation of the entire immunoassay procedure for high processing capacity.

  7. Reflotron cholesterol measurement in general practice: accuracy and detection of errors.

    PubMed

    Ball, M J; Robertson, I K; Woods, M

    1994-11-01

    Comparison of cholesterol determinations by nurses using a Reflotron analyser in a general practice setting showed a good correlation with plasma cholesterol determinations by wet chemistry in a clinical biochemistry laboratory. A limited number of comparisons did, however, give a much lower result on the Reflotron. In an experimental situation, small sample volumes (which could result from poor technique) were shown to produce falsely low readings. A simple method which may immediately detect falsely low Reflotron readings is discussed.

  8. Micro-satellite for space debris observation by optical sensors

    NASA Astrophysics Data System (ADS)

    Thillot, Marc; Brenière, Xavier; Midavaine, Thierry

    2017-11-01

    The purpose of this theoretical study carried out under CNES contract is to analyze the feasibility of small space debris detection and classification with an optical sensor on-board micro-satellite. Technical solutions based on active and passive sensors are analyzed and compared. For the most appropriated concept an optimization was made and theoretical performances in terms of number of detection versus class of diameter were calculated. Finally we give some preliminary physical sensor features to illustrate the concept (weight, volume, consumption,…).

  9. Detection of prostate cancer index lesions with multiparametric magnetic resonance imaging (mp-MRI) using whole-mount histological sections as the reference standard.

    PubMed

    Russo, Filippo; Regge, Daniele; Armando, Enrico; Giannini, Valentina; Vignati, Anna; Mazzetti, Simone; Manfredi, Matteo; Bollito, Enrico; Correale, Loredana; Porpiglia, Francesco

    2016-07-01

    To evaluate the sensitivity of multiparametric magnetic resonance imaging (mp-MRI) for detecting prostate cancer foci, including the largest (index) lesions. In all, 115 patients with biopsy confirmed prostate cancer underwent mp-MRI before radical prostatectomy. A single expert radiologist recorded all prostate cancer foci including the index lesion 'blinded' to the pathologist's biopsy report. Stained whole-mount histological sections were used as the reference standard. All lesions were contoured by an experienced uropathologist who assessed their volume and pathological Gleason score. All lesions with a volume of >0.5 mL and/or pathological Gleason score of >6 were defined as clinically significant prostate cancer. Multivariate analysis was used to ascertain the characteristics of lesions identified by MRI. In all, 104 of 115 index lesions were correctly diagnosed by mp-MRI (sensitivity 90.4%; 95% confidence interval [CI] 83.5-95.1%), including 98/105 clinically significant index lesions (93.3%; 95% CI 86.8-97.3%), among which three of three lesions had a volume of <0.5 mL and Gleason score of >6. Overall, mp-MRI detected 131/206 lesions including 13 of 68 'insignificant' prostate cancers. The multivariate logistic regression modelling showed that pathological Gleason score (odds ratio [OR] 11.7, 95% CI 2.3-59.8; P = 0.003) and lesion volume (OR 4.24, 95% CI 1.3-14.7; P = 0.022) were independently associated with the detection of index lesions at MRI. This study shows that mp-MRI has a high sensitivity for detecting clinically significant prostate cancer index lesions, while having disappointing results for the detection of small-volume, low Gleason score prostate cancer foci. Thus, mp-MRI could be used to stratify patients according to risk, allowing better treatment selection. © 2015 The Authors BJU International © 2015 BJU International Published by John Wiley & Sons Ltd.

  10. Real-Time, Single-Step Bioassay Using Nanoplasmonic Resonator With Ultra-High Sensitivity

    NASA Technical Reports Server (NTRS)

    Zhang, Xiang (Inventor); Chen, Fanqing Frank (Inventor); Su, Kai-Hang (Inventor); Wei, Qi-Huo (Inventor); Ellman, Jonathan A. (Inventor); Sun, Cheng (Inventor)

    2014-01-01

    A nanoplasmonic resonator (NPR) comprising a metallic nanodisk with alternating shielding layer(s), having a tagged biomolecule conjugated or tethered to the surface of the nanoplasmonic resonator for highly sensitive measurement of enzymatic activity. NPRs enhance Raman signals in a highly reproducible manner, enabling fast detection of protease and enzyme activity, such as Prostate Specific Antigen (paPSA), in real-time, at picomolar sensitivity levels. Experiments on extracellular fluid (ECF) from paPSA-positive cells demonstrate specific detection in a complex bio-fluid background in real-time single-step detection in very small sample volumes.

  11. Real-time, single-step bioassay using nanoplasmonic resonator with ultra-high sensitivity

    DOEpatents

    Zhang, Xiang; Ellman, Jonathan A; Chen, Fanqing Frank; Su, Kai-Hang; Wei, Qi-Huo; Sun, Cheng

    2014-04-01

    A nanoplasmonic resonator (NPR) comprising a metallic nanodisk with alternating shielding layer(s), having a tagged biomolecule conjugated or tethered to the surface of the nanoplasmonic resonator for highly sensitive measurement of enzymatic activity. NPRs enhance Raman signals in a highly reproducible manner, enabling fast detection of protease and enzyme activity, such as Prostate Specific Antigen (paPSA), in real-time, at picomolar sensitivity levels. Experiments on extracellular fluid (ECF) from paPSA-positive cells demonstrate specific detection in a complex bio-fluid background in real-time single-step detection in very small sample volumes.

  12. Adaptation of reference volumes for correlation-based digital holographic particle tracking

    NASA Astrophysics Data System (ADS)

    Hesseling, Christina; Peinke, Joachim; Gülker, Gerd

    2018-04-01

    Numerically reconstructed reference volumes tailored to particle images are used for particle position detection by means of three-dimensional correlation. After a first tracking of these positions, the experimentally recorded particle images are retrieved as a posteriori knowledge about the particle images in the system. This knowledge is used for a further refinement of the detected positions. A transparent description of the individual algorithm steps including the results retrieved with experimental data complete the paper. The work employs extraordinarily small particles, smaller than the pixel pitch of the camera sensor. It is the first approach known to the authors that combines numerical knowledge about particle images and particle images retrieved from the experimental system to an iterative particle tracking approach for digital holographic particle tracking velocimetry.

  13. Using large volume samplers for the monitoring of particle bound micro pollutants in rivers

    NASA Astrophysics Data System (ADS)

    Kittlaus, Steffen; Fuchs, Stephan

    2015-04-01

    The requirements of the WFD as well as substance emission modelling at the river basin scale require stable monitoring data for micro pollutants. The monitoring concepts applied by the local authorities as well as by many scientists use single sampling techniques. Samples from water bodies are usually taken in volumes of about one litre and depending on predetermined time steps or through discharge thresholds. For predominantly particle bound micro pollutants the small sample size of about one litre results in a very small amount of suspended particles. To measure micro pollutant concentrations in these samples is demanding and results in a high uncertainty of the measured concentrations, if the concentration is above the detection limit in the first place. In many monitoring programs most of the measured values were below the detection limit. This results in a high uncertainty if river loads were calculated from these data sets. The authors propose a different approach to gain stable concentration values for particle bound micro pollutants from river monitoring: A mixed sample of about 1000 L was pumped in a tank with a dirty-water pump. The sampling usually is done discharge dependant by using a gauge signal as input for the control unit. After the discharge event is over or the tank is fully filled, the suspended solids settle in the tank for 2 days. After this time a clear separation of water and solids can be shown. A sample (1 L) from the water phase and the total mass of the settled solids (about 10 L) are taken to the laboratory for analysis. While the micro pollutants can't hardly be detected in the water phase, the signal from the sediment is high above the detection limit, thus certain and very stable. From the pollutant concentration in the solid phase and the total tank volume the initial pollutant concentration in the sample can be calculated. If the concentration in the water phase is detectable, it can be used to correct the total load. This relatively low cost approach (less costs for analysis because of small sample number) allows to quantify the pollutant load, to derive dissolved-solid partition coefficients and to quantify the pollutant load in different particle size classes.

  14. Rapid Evaluation of Platelet Function With T2 Magnetic Resonance

    PubMed Central

    Cuker, Adam; Husseinzadeh, Holleh; Lebedeva, Tatiana; Marturano, Joseph E.; Massefski, Walter; Lowery, Thomas J.; Lambert, Michele P.; Abrams, Charles S.; Weisel, John W.

    2016-01-01

    Objectives: The clinical diagnosis of qualitative platelet disorders (QPDs) based on light transmission aggregometry (LTA) requires significant blood volume, time, and expertise, all of which can be barriers to utilization in some populations and settings. Our objective was to develop a more rapid assay of platelet function by measuring platelet-mediated clot contraction in small volumes (35 µL) of whole blood using T2 magnetic resonance (T2MR). Methods: We established normal ranges for platelet-mediated clot contraction using T2MR, used these ranges to study patients with known platelet dysfunction, and then evaluated agreement between T2MR and LTA with arachidonic acid, adenosine diphosphate, epinephrine, and thrombin receptor activator peptide. Results: Blood from 21 healthy donors was studied. T2MR showed 100% agreement with LTA with each of the four agonists and their cognate inhibitors tested. T2MR successfully detected abnormalities in each of seven patients with known QPDs, with the exception of one patient with a novel mutation leading to Hermansky-Pudlak syndrome. T2MR appeared to detect platelet function at similar or lower platelet counts than LTA. Conclusions: T2MR may provide a clinically useful approach to diagnose QPDs using small volumes of whole blood, while also providing new insight into platelet biology not evident using plasma-based platelet aggregation tests. PMID:28028118

  15. Aerial Vehicles to Detect Maximum Volume of Plume Material Associated with Habitable Areas in Extreme Environments

    NASA Technical Reports Server (NTRS)

    Gunasekara, Onalli; Wong, Uland Y.; Furlong, Michael P.; Dille, Michael

    2017-01-01

    Current technologies of exploring habitable areas of icy moons are limited to flybys of space probes. This research project addresses long-term navigation of icy moons by developing a MATLAB adjustable trajectory based on the volume of plume material observed. Plumes expose materials from the sub-surface without accessing the subsurface. Aerial vehicles capable of scouting vapor plumes and detecting maximum plume material volumes, which are considered potentially habitable in inhospitable environments, would enable future deep-space missions to search for extraterrestrial organisms on the surface of icy moons. Although this platform is still a prototype, it demonstrates the potential aerial vehicles can have in improving the capabilities of long-term space navigation and enabling technology for detecting life in extreme environments. Additionally, this work is developing the capabilities that could be utilized as a platform for space biology research. For example, aerial vehicles that are sent to map extreme environments of icy moons or the planet Mars, could also carry small payloads with automated cell-biology experiments, designed to probe the biological response of low-gravity and high-radiation planetary environments, serving as a pathfinder for future human missions.

  16. Association of Progressive Multifocal Leukoencephalopathy Lesion Volume With JC Virus Polymerase Chain Reaction Results in Cerebrospinal Fluid of Natalizumab-Treated Patients With Multiple Sclerosis.

    PubMed

    Wijburg, Martijn T; Kleerekooper, Iris; Lissenberg-Witte, Birgit I; de Vos, Marlieke; Warnke, Clemens; Uitdehaag, Bernard M J; Barkhof, Frederik; Killestein, Joep; Wattjes, Mike P

    2018-03-12

    The JC virus (JCV) was named after the first patient to be described with progressive multifocal leukoencephalopathy (PML), John Cunningham. Detection of JC virus DNA in cerebrospinal fluid (CSF) by polymerase chain reaction (PCR), and of specific lesions by brain magnetic resonance imaging (MRI), are both considered essential for the diagnosis of natalizumab-associated PML (NTZ-PML) in patients with multiple sclerosis. However, strict pharmacovigilance by MRI can result in detection of patients with small lesions and undetectable JCV DNA in CSF. To investigate the association of PML lesion characteristics on MRI with both qualitative and quantitative JCV PCR results in CSF of patients with NTZ-PML. This was a retrospective, cross-sectional study conducted from January 2007 to December 2014 in patients considered to have NTZ-PML based on a set of predefined criteria. Follow-up was at least 6 months. Data of patients from the Dutch-Belgian NTZ-PML cohort and patients treated at multiple medical centers in Belgium and the Netherlands and selected for research purposes were included as a convenience sample. Brain MRI scans were analyzed for PML lesion volume, location, dissemination, and signs of inflammation. Associations of the qualitative and quantitative CSF JCV PCR results with PML MRI characteristics were calculated. Of the 73 patients screened, 56 were included (37 were women). At inclusion, 9 patients (16.1%) had undetectable JCV DNA in CSF. Patients with a positive PCR had larger total PML lesion volumes than those with undetectable JCV DNA (median volume, 22.9 mL; interquartile range, 9.2-60.4 mL vs median volume, 6.7 mL; interquartile range, 4.9-14.7 mL; P = .008), and logistic regression showed that a lower PML lesion volume significantly increased the probability for undetectable JCV DNA. There was a positive correlation between PML lesion volume and JCV copy numbers (Spearman ρ, 0.32; P = .03). Progressive multifocal leukoencephalopathy lesion volume was higher in patients with PML symptoms and in patients with more widespread lesion dissemination. No association was found between PCR results and PML lesion dissemination, signs of inflammation, or PML symptoms. Smaller NTZ-PML lesions are associated with a higher likelihood of undetectable JCV DNA in CSF. This may preclude a formal diagnosis of PML and can complicate patient treatment in patients with small MRI lesions highly suggestive of PML detected early through pharmacovigilance.

  17. A Small-scale Model to Assess the Risk of Leachables from Single-use Bioprocess Containers through Protein Quality Characterization.

    PubMed

    Xiao, Nina J; Medley, Colin D; Shieh, Ian C; Downing, Gregory; Pizarro, Shelly; Liu, Jun; Patel, Ankit R

    Leachables from single-use bioprocess containers (BPCs) are a source of process-related impurities that have the potential to alter product quality of biotherapeutics and affect patient health. Leachables often exist at very low concentrations, making it difficult to detect their presence and challenging to assess their impact on protein quality. A small-scale stress model based on assessing protein stability was developed to evaluate the potential risks associated with storing biotherapeutics in disposable bags caused by the presence of leachables. Small-scale BPCs were filled with protein solution at high surface area-to-volume ratios (≥3× the surface area-to-volume ratio of manufacturing-scale BPCs) and incubated at stress temperatures (e.g., 25 °C or 30 °C for up to 12 weeks) along with an appropriate storage vessel (e.g., glass vial or stainless steel) as a control for side-by-side comparison. Changes in protein size variants measured by size exclusion chromatography, capillary electrophoresis, and particle formation for two monoclonal antibodies using both the small-scale stress model and a control revealed a detrimental effect of gamma-irradiated BPCs on protein aggregation and significant BPC difference between earlier and later batches. It was found that preincubation of the empty BPCs prior to protein storage improved protein stability, suggesting the presence of volatile or heat-sensitive leachables (heat-labile or thermally degraded). In addition, increasing the polysorbate 20 concentration lowered, but did not completely mitigate, the leachable-protein interactions, indicating the presence of a hydrophobic leachable. Overall, this model can inform the risk of BPC leachables on biotherapeutics during routine manufacturing and assist in making decisions on the selection of a suitable BPC for the manufacturing process by assessing changes in product quality. Leachables from single-use systems often exist in small quantities and are difficult to detect with existing analytical methods. The presence of relevant detrimental leachables from single-use bioprocess containers (BPCs) can be indirectly detected by studying the stability of monoclonal antibodies via changes by size exclusion chromatography, capillary electrophoresis sodium dodecyl sulfate, and visible/sub-visible particles using a small-scale stress model containing high surface area-to-volume ratio at elevated temperature alongside with an appropriate control (e.g., glass vials or stainless steel containers). These changes in protein quality attributes allowed the evaluation of potential risks associated with adopting single-use bioprocess containers for storage as well as bag quality and bag differences between earlier and later batches. These leachables appear to be generated during the bag sterilization process by gamma irradiation. Improvements in protein stability after storage in "preheated" bags indicated that these leachables may be thermally unstable or volatile. The effect of surfactant levels, storage temperatures, surface area-to-volume ratios, filtration, and buffer exchange on leachables and protein stability were also assessed. © PDA, Inc. 2016.

  18. Drop-on-demand sample introduction system coupled with the flowing atmospheric-pressure afterglow for direct molecular analysis of complex liquid micro-volume samples

    PubMed Central

    Schaper, J. Niklas; Pfeuffer, Kevin P.; Shelley, Jacob T.; Bings, Nicolas H.

    2012-01-01

    One of the fastest developing fields in analytical spectrochemistry in recent years is ambient desorption/ionization mass spectrometry (ADI-MS). This burgeoning interest has been due to the demonstrated advantages of the method: simple mass spectra, little or no sample preparation, and applicability to samples in the solid, liquid, or gaseous state. One such ADI-MS source, the flowing atmospheric-pressure afterglow (FAPA), is capable of direct analysis of solids just by aiming the source at the solid surface and sampling the produced ions into a mass spectrometer. However, direct introduction of significant volumes of liquid samples into this source has not been possible, as solvent loads can quench the afterglow and, thus, the formation of reagent ions. As a result, the analysis of liquid samples is preferably carried out by analyzing dried residues or by desorbing small amounts of liquid samples directly from the liquid surface. In the former case, reproducibility of sample introduction is crucial if quantitative results are desired. In the present study, introduction of liquid samples as very small droplets helps overcome the issues of sample positioning and reduced levels of solvent intake. A recently developed “drop-on-demand” (DOD) aerosol generator is capable of reproducibly producing very small volumes of liquid (~17 pL). In this paper, the coupling of FAPA-MS and DOD is reported and applications are suggested. Analytes representing different classes of substances were tested and limits of detections were determined. Matrix tolerance was investigated for drugs of abuse and their metabolites by analyzing raw urine samples and quantification without the use of internal standards. Limits of detection below 2 µg/mL, without sample pretreatment, were obtained. PMID:23025277

  19. Higher cost of implementing Xpert(®) MTB/RIF in Ugandan peripheral settings: implications for cost-effectiveness.

    PubMed

    Hsiang, E; Little, K M; Haguma, P; Hanrahan, C F; Katamba, A; Cattamanchi, A; Davis, J L; Vassall, A; Dowdy, D

    2016-09-01

    Initial cost-effectiveness evaluations of Xpert(®) MTB/RIF for tuberculosis (TB) diagnosis have not fully accounted for the realities of implementation in peripheral settings. To evaluate costs and diagnostic outcomes of Xpert testing implemented at various health care levels in Uganda. We collected empirical cost data from five health centers utilizing Xpert for TB diagnosis, using an ingredients approach. We reviewed laboratory and patient records to assess outcomes at these sites and10 sites without Xpert. We also estimated incremental cost-effectiveness of Xpert testing; our primary outcome was the incremental cost of Xpert testing per newly detected TB case. The mean unit cost of an Xpert test was US$21 based on a mean monthly volume of 54 tests per site, although unit cost varied widely (US$16-58) and was primarily determined by testing volume. Total diagnostic costs were 2.4-fold higher in Xpert clinics than in non-Xpert clinics; however, Xpert only increased diagnoses by 12%. The diagnostic costs of Xpert averaged US$119 per newly detected TB case, but were as high as US$885 at the center with the lowest volume of tests. Xpert testing can detect TB cases at reasonable cost, but may double diagnostic budgets for relatively small gains, with cost-effectiveness deteriorating with lower testing volumes.

  20. MRI Brain Tumor Segmentation and Necrosis Detection Using Adaptive Sobolev Snakes.

    PubMed

    Nakhmani, Arie; Kikinis, Ron; Tannenbaum, Allen

    2014-03-21

    Brain tumor segmentation in brain MRI volumes is used in neurosurgical planning and illness staging. It is important to explore the tumor shape and necrosis regions at different points of time to evaluate the disease progression. We propose an algorithm for semi-automatic tumor segmentation and necrosis detection. Our algorithm consists of three parts: conversion of MRI volume to a probability space based on the on-line learned model, tumor probability density estimation, and adaptive segmentation in the probability space. We use manually selected acceptance and rejection classes on a single MRI slice to learn the background and foreground statistical models. Then, we propagate this model to all MRI slices to compute the most probable regions of the tumor. Anisotropic 3D diffusion is used to estimate the probability density. Finally, the estimated density is segmented by the Sobolev active contour (snake) algorithm to select smoothed regions of the maximum tumor probability. The segmentation approach is robust to noise and not very sensitive to the manual initialization in the volumes tested. Also, it is appropriate for low contrast imagery. The irregular necrosis regions are detected by using the outliers of the probability distribution inside the segmented region. The necrosis regions of small width are removed due to a high probability of noisy measurements. The MRI volume segmentation results obtained by our algorithm are very similar to expert manual segmentation.

  1. MRI brain tumor segmentation and necrosis detection using adaptive Sobolev snakes

    NASA Astrophysics Data System (ADS)

    Nakhmani, Arie; Kikinis, Ron; Tannenbaum, Allen

    2014-03-01

    Brain tumor segmentation in brain MRI volumes is used in neurosurgical planning and illness staging. It is important to explore the tumor shape and necrosis regions at di erent points of time to evaluate the disease progression. We propose an algorithm for semi-automatic tumor segmentation and necrosis detection. Our algorithm consists of three parts: conversion of MRI volume to a probability space based on the on-line learned model, tumor probability density estimation, and adaptive segmentation in the probability space. We use manually selected acceptance and rejection classes on a single MRI slice to learn the background and foreground statistical models. Then, we propagate this model to all MRI slices to compute the most probable regions of the tumor. Anisotropic 3D di usion is used to estimate the probability density. Finally, the estimated density is segmented by the Sobolev active contour (snake) algorithm to select smoothed regions of the maximum tumor probability. The segmentation approach is robust to noise and not very sensitive to the manual initialization in the volumes tested. Also, it is appropriate for low contrast imagery. The irregular necrosis regions are detected by using the outliers of the probability distribution inside the segmented region. The necrosis regions of small width are removed due to a high probability of noisy measurements. The MRI volume segmentation results obtained by our algorithm are very similar to expert manual segmentation.

  2. Airborne chemistry: acoustic levitation in chemical analysis.

    PubMed

    Santesson, Sabina; Nilsson, Staffan

    2004-04-01

    This review with 60 references describes a unique path to miniaturisation, that is, the use of acoustic levitation in analytical and bioanalytical chemistry applications. Levitation of small volumes of sample by means of a levitation technique can be used as a way to avoid solid walls around the sample, thus circumventing the main problem of miniaturisation, the unfavourable surface-to-volume ratio. Different techniques for sample levitation have been developed and improved. Of the levitation techniques described, acoustic or ultrasonic levitation fulfils all requirements for analytical chemistry applications. This technique has previously been used to study properties of molten materials and the equilibrium shape()and stability of liquid drops. Temperature and mass transfer in levitated drops have also been described, as have crystallisation and microgravity applications. The airborne analytical system described here is equipped with different and exchangeable remote detection systems. The levitated drops are normally in the 100 nL-2 microL volume range and additions to the levitated drop can be made in the pL-volume range. The use of levitated drops in analytical and bioanalytical chemistry offers several benefits. Several remote detection systems are compatible with acoustic levitation, including fluorescence imaging detection, right angle light scattering, Raman spectroscopy, and X-ray diffraction. Applications include liquid/liquid extractions, solvent exchange, analyte enrichment, single-cell analysis, cell-cell communication studies, precipitation screening of proteins to establish nucleation conditions, and crystallisation of proteins and pharmaceuticals.

  3. Refinements of environmental assessment during an outbreak investigation of invasive aspergillosis in a leukemia and bone marrow transplant unit.

    PubMed

    Thio, C L; Smith, D; Merz, W G; Streifel, A J; Bova, G; Gay, L; Miller, C B; Perl, T M

    2000-01-01

    To investigate an outbreak of aspergillosis in a leukemia and bone marrow transplant (BMT) unit and to improve environmental assessment strategies to detect Aspergillus. Epidemiological investigation and detailed environmental assessment. A tertiary-care university hospital with a 37-bed leukemia and BMT unit Leukemic or BMT patients with invasive aspergillosis identified through prospective surveillance and confirmed by chart review. We verified the diagnosis of invasive fungal infection by reviewing medical charts of at-risk patients, performing a case-control study to determine risk factors for infection, instituting wet mopping to clean all floors, providing N95 masks to protect patients outside high-efficiency particulate air (HEPA)-filtered areas, altering traffic patterns into the unit, and performing molecular typing of selected Aspergillus flavus isolates. To assess the environment, we verified pressure relationships between the rooms and hallway and between buildings, and we compared the ability of large-volume (1,200 L) and small-volume (160 L) air samplers to detect Aspergillus spores. Of 29 potential invasive aspergillosis cases, 21 were confirmed by medical chart review. Risk factors for developing invasive aspergillosis included the length of time since malignancy was diagnosed (odds ratio [OR], 1.0; P=.05) and hospitalization in a patient room located near a stairwell door (OR, 3.7; P=.05). Two of five A. flavus patient isolates were identical to one of the environmental isolates. The pressure in most of the rooms was higher than in the corridors, but the pressure in the oncology unit was negative with respect to the physically adjacent hospital; consequently, the unit acted essentially as a vacuum that siphoned non-HEPA-filtered air from the main hospital. Of the 78 samples obtained with a small-volume air sampler, none grew an Aspergillus species, whereas 10 of 40 cultures obtained with a large-volume air sampler did. During active construction, Aspergillus spores may have entered the oncology unit from the physically adjacent hospital because the air pressure differed. Guidelines that establish the minimum acceptable pressures and specify which pressure relationships to test in healthcare settings are needed. Our data show that large-volume air samples are superior to small-volume samples to assess for Aspergillus in the healthcare environment.

  4. SU-E-I-10: Investigation On Detectability of a Small Target for Different Slice Direction of a Volumetric Cone Beam CT Image

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, C; Han, M; Baek, J

    Purpose: To investigate the detectability of a small target for different slice direction of a volumetric cone beam CT image and its impact on dose reduction. Methods: Analytic projection data of a sphere object (1 mm diameter, 0.2/cm attenuation coefficient) were generated and reconstructed by FDK algorithm. In this work, we compared the detectability of the small target from four different backprojection Methods: hanning weighted ramp filter with linear interpolation (RECON 1), hanning weighted ramp filter with Fourier interpolation (RECON2), ramp filter with linear interpolation (RECON 3), and ramp filter with Fourier interpolation (RECON4), respectively. For noise simulation, 200 photonsmore » per measurement were used, and the noise only data were reconstructed using FDK algorithm. For each reconstructed volume, axial and coronal slice were extracted and detection-SNR was calculated using channelized Hotelling observer (CHO) with dense difference-of-Gaussian (D-DOG) channels. Results: Detection-SNR of coronal images varies for different backprojection methods, while axial images have a similar detection-SNR. Detection-SNR{sup 2} ratios of coronal and axial images in RECON1 and RECON2 are 1.33 and 1.15, implying that the coronal image has a better detectability than axial image. In other words, using coronal slices for the small target detection can reduce the patient dose about 33% and 15% compared to using axial slices in RECON 1 and RECON 2. Conclusion: In this work, we investigated slice direction dependent detectability of a volumetric cone beam CT image. RECON 1 and RECON 2 produced the highest detection-SNR, with better detectability in coronal slices. These results indicate that it is more beneficial to use coronal slice to improve detectability of a small target in a volumetric cone beam CT image. This research was supported by the MSIP (Ministry of Science, ICT and Future Planning), Korea, under the IT Consilience Creative Program (NIPA-2014-H0201-14-1002) supervised by the NIPA (National IT Industry Promotion Agency). Authors declares that s/he has no conflict of Interest in relation to the work in this abstract.« less

  5. Antenna-Coupled Superconducting Tunnel Junctions with Single-Electron Transistor Readout for Detection of Sub-mm Radiation

    NASA Technical Reports Server (NTRS)

    Stevenson, T. R.; Hsieh, W.-T.; Li, M. J.; Stahle, C. M.; Wollack, E. J.; Schoelkopf, R. J.; Teufel, J.; Krebs, Carolyn (Technical Monitor)

    2002-01-01

    Antenna-coupled superconducting tunnel junction detectors have the potential for photon-counting sensitivity at sub-mm wavelengths. The device consists of an antenna structure to couple radiation into a small superconducting volume and cause quasiparticle excitations, and a single-electron transistor to measure currents through tunnel junction contacts to the absorber volume. We will describe optimization of device parameters, and recent results on fabrication techniques for producing devices with high yield for detector arrays. We will also present modeling of expected saturation power levels, antenna coupling, and rf multiplexing schemes.

  6. Design of an integrated sensor system for the detection of traces of different molecules in the air

    NASA Astrophysics Data System (ADS)

    Strle, D.; Muševič, I.

    2015-04-01

    This article presents the design of a miniature detection system and its associated signal processing electronics, which can detect and selectively recognize vapor traces of different materials in the air - including explosives. It is based on the array of surface-functionalized COMB capacitive sensors and extremely low noise, analog, integrated electronic circuit, hardwired digital signal processing hardware and additional software running on a PC. The instrument is sensitive and selective, consumes a minimum amount of energy, is very small (few mm3) and cheap to produce in large quantities, and is insensitive to mechanical influences. Using an electronic detection system built of low noise analog front-end and hard-wired digital signal processing, it is possible to detect less than 0.3ppt of TNT molecules in the atmosphere (3 TNT molecules in 1013 molecules of the air) at 25°C on a 1 Hz bandwidth using very small volume and approx. 10 mA current from a 5V supply voltage. The sensors are implemented in a modified MEMS process and analog electronics in 0.18 um CMOS technology.

  7. [Design of Portable Spirometer Based on Internet of Things of Medicine].

    PubMed

    He, Yichen; Yang, Bo; Xiong, Shiqi; Li, Qing

    2018-02-08

    A kind of portable device for detecting common lung function parameters is mentioned in this paper. Using the singlechip microcomputer as the master control block to collect and process the data from high-accuracy gas pressure sensor, through the way of parametric calibration and linear interpolation to test and calculate the Forced Vital Capacity (FVC), Peak Expiratory Flow (PEF), Forced Expiratory Volume in one second (FEV1), and FEV1/FVC. Meanwhile, the detected parameters can be uploaded to the intelligent mobile terminal through the wireless transmission module. The device is able to show expiratory volume-time curve and the final parameters clearly, the error of measurement is less than 5%. In addition, that device is small and convenient, not only is good for clinical application, but also can be used for family in a house.

  8. A finite element model of remote palpation of breast lesions using radiation force: factors affecting tissue displacement.

    PubMed

    Nightingale, K R; Nightingale, R W; Palmeri, M L; Trahey, G E

    2000-01-01

    The early detection of breast cancer reduces patient mortality. The most common method of breast cancer detection is palpation. However, lesions that lie deep within the breast are difficult to palpate when they are small. Thus, a method of remote palpation, which may allow the detection of small lesions lying deep within the breast, is currently under investigation. In this method, acoustic radiation force is used to apply localized forces within tissue (to tissue volumes on the order of 2 mm3) and the resulting tissue displacements are mapped using ultrasonic correlation based methods. A volume of tissue that is stiffer than the surrounding medium (i.e., a lesion) distributes the force throughout the tissue beneath it, resulting in larger regions of displacement, and smaller maximum displacements. The resulting displacement maps may be used to image tissue stiffness. A finite-element-model (FEM) of acoustic remote palpation is presented in this paper. Using this model, a parametric analysis of the affect of varying tissue and acoustic beam characteristics on radiation force induced tissue displacements is performed. The results are used to evaluate the potential of acoustic remote palpation to provide useful diagnostic information in a clinical setting. The potential for using a single diagnostic transducer to both generate radiation force and track the resulting displacements is investigated.

  9. Real-time 3D change detection of IEDs

    NASA Astrophysics Data System (ADS)

    Wathen, Mitch; Link, Norah; Iles, Peter; Jinkerson, John; Mrstik, Paul; Kusevic, Kresimir; Kovats, David

    2012-06-01

    Road-side bombs are a real and continuing threat to soldiers in theater. CAE USA recently developed a prototype Volume based Intelligence Surveillance Reconnaissance (VISR) sensor platform for IED detection. This vehicle-mounted, prototype sensor system uses a high data rate LiDAR (1.33 million range measurements per second) to generate a 3D mapping of roadways. The mapped data is used as a reference to generate real-time change detection on future trips on the same roadways. The prototype VISR system is briefly described. The focus of this paper is the methodology used to process the 3D LiDAR data, in real-time, to detect small changes on and near the roadway ahead of a vehicle traveling at moderate speeds with sufficient warning to stop the vehicle at a safe distance from the threat. The system relies on accurate navigation equipment to geo-reference the reference run and the change-detection run. Since it was recognized early in the project that detection of small changes could not be achieved with accurate navigation solutions alone, a scene alignment algorithm was developed to register the reference run with the change detection run prior to applying the change detection algorithm. Good success was achieved in simultaneous real time processing of scene alignment plus change detection.

  10. Inpatient Rehabilitation Volume and Functional Outcomes in Stroke, Lower Extremity Fracture, and Lower Extremity Joint Replacement

    PubMed Central

    Graham, James E.; Deutsch, Anne; O’Connell, Ann A.; Karmarkar, Amol M.; Granger, Carl V.; Ottenbacher, Kenneth J.

    2013-01-01

    Background It is unclear if volume-outcome relationships exist in inpatient rehabilitation. Objectives Assess associations between facility volumes and two patient-centered outcomes in the three most common diagnostic groups in inpatient rehabilitation. Research Design We used hierarchical linear and generalized linear models to analyze administrative assessment data from patients receiving inpatient rehabilitation services for stroke (n=202,423), lower extremity fracture (n=132,194), or lower extremity joint replacement (n=148,068) between 2006 and 2008 in 717 rehabilitation facilities across the U.S. Facilities were assigned to quintiles based on average annual diagnosis-specific patient volumes. Measures Discharge functional status (FIM instrument) and probability of home discharge. Results Facility-level factors accounted for 6–15% of the variance in discharge FIM total scores and 3–5% of the variance in home discharge probability across the 3 diagnostic groups. We used the middle volume quintile (Q3) as the reference group for all analyses and detected small, but statistically significant (p < .01) associations with discharge functional status in all three diagnosis groups. Only the highest volume quintile (Q5) reached statistical significance, displaying higher functional status ratings than Q3 each time. The largest effect was observed in FIM total scores among fracture patients, with only a 3.6-point difference in Q5 and Q3 group means. Volume was not independently related to home discharge. Conclusions Outcome-specific volume effects ranged from small (functional status) to none (home discharge) in all three diagnostic groups. Patients with these conditions can be treated locally rather than at higher-volume regional centers. Further regionalization of inpatient rehabilitation services is not needed for these conditions. PMID:23579350

  11. Inpatient rehabilitation volume and functional outcomes in stroke, lower extremity fracture, and lower extremity joint replacement.

    PubMed

    Graham, James E; Deutsch, Anne; O'Connell, Ann A; Karmarkar, Amol M; Granger, Carl V; Ottenbacher, Kenneth J

    2013-05-01

    It is unclear if volume-outcome relationships exist in inpatient rehabilitation. Assess associations between facility volumes and 2 patient-centered outcomes in the 3 most common diagnostic groups in inpatient rehabilitation. We used hierarchical linear and generalized linear models to analyze administrative assessment data from patients receiving inpatient rehabilitation services for stroke (n=202,423), lower extremity fracture (n=132,194), or lower extremity joint replacement (n=148,068) between 2006 and 2008 in 717 rehabilitation facilities across the United States. Facilities were assigned to quintiles based on average annual diagnosis-specific patient volumes. Discharge functional status (FIM instrument) and probability of home discharge. Facility-level factors accounted for 6%-15% of the variance in discharge FIM total scores and 3%-5% of the variance in home discharge probability across the 3 diagnostic groups. We used the middle volume quintile (Q3) as the reference group for all analyses and detected small, but statistically significant (P<0.01) associations with discharge functional status in all 3 diagnosis groups. Only the highest volume quintile (Q5) reached statistical significance, displaying higher functional status ratings than Q3 each time. The largest effect was observed in FIM total scores among fracture patients, with only a 3.6-point difference in Q5 and Q3 group means. Volume was not independently related to home discharge. Outcome-specific volume effects ranged from small (functional status) to none (home discharge) in all 3 diagnostic groups. Patients with these conditions can be treated locally rather than at higher volume regional centers. Further regionalization of inpatient rehabilitation services is not needed for these conditions.

  12. Detection and volume estimation of artificial hematomas in the subcutaneous fatty tissue: comparison of different MR sequences at 3.0 T.

    PubMed

    Ogris, Kathrin; Petrovic, Andreas; Scheicher, Sylvia; Sprenger, Hanna; Urschler, Martin; Hassler, Eva Maria; Yen, Kathrin; Scheurer, Eva

    2017-06-01

    In legal medicine, reliable localization and analysis of hematomas in subcutaneous fatty tissue is required for forensic reconstruction. Due to the absence of ionizing radiation, magnetic resonance imaging (MRI) is particularly suited to examining living persons with forensically relevant injuries. However, there is limited experience regarding MRI signal properties of hemorrhage in soft tissue. The aim of this study was to evaluate MR sequences with respect to their ability to show high contrast between hematomas and subcutaneous fatty tissue as well as to reliably determine the volume of artificial hematomas. Porcine tissue models were prepared by injecting blood into the subcutaneous fatty tissue to create artificial hematomas. MR images were acquired at 3T and four blinded observers conducted manual segmentation of the hematomas. To assess segmentability, the agreement of measured volume with the known volume of injected blood was statistically analyzed. A physically motivated normalization taking into account partial volume effect was applied to the data to ensure comparable results among differently sized hematomas. The inversion recovery sequence exhibited the best segmentability rate, whereas the T1T2w turbo spin echo sequence showed the most accurate results regarding volume estimation. Both sequences led to reproducible volume estimations. This study demonstrates that MRI is a promising forensic tool to assess and visualize even very small amounts of blood in soft tissue. The presented results enable the improvement of protocols for detection and volume determination of hemorrhage in forensically relevant cases and also provide fundamental knowledge for future in-vivo examinations.

  13. Detecting bacteria and Determining Their Susceptibility to Antibiotics by Stochastic Confinement in Nanoliter Droplets using Plug-Based Microfluidics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boedicker, J.; Li, L; Kline, T

    2008-01-01

    This article describes plug-based microfluidic technology that enables rapid detection and drug susceptibility screening of bacteria in samples, including complex biological matrices, without pre-incubation. Unlike conventional bacterial culture and detection methods, which rely on incubation of a sample to increase the concentration of bacteria to detectable levels, this method confines individual bacteria into droplets nanoliters in volume. When single cells are confined into plugs of small volume such that the loading is less than one bacterium per plug, the detection time is proportional to plug volume. Confinement increases cell density and allows released molecules to accumulate around the cell, eliminatingmore » the pre-incubation step and reducing the time required to detect the bacteria. We refer to this approach as stochastic confinement. Using the microfluidic hybrid method, this technology was used to determine the antibiogram - or chart of antibiotic sensitivity - of methicillin-resistant Staphylococcus aureus (MRSA) to many antibiotics in a single experiment and to measure the minimal inhibitory concentration (MIC) of the drug cefoxitin (CFX) against this strain. In addition, this technology was used to distinguish between sensitive and resistant strains of S. aureus in samples of human blood plasma. High-throughput microfluidic techniques combined with single-cell measurements also enable multiple tests to be performed simultaneously on a single sample containing bacteria. This technology may provide a method of rapid and effective patient-specific treatment of bacterial infections and could be extended to a variety of applications that require multiple functional tests of bacterial samples on reduced timescales.« less

  14. 40 CFR 86.1826-01 - Assigned deterioration factors for small volume manufacturers and small volume test groups.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... durability groups) that is equipped with unproven emission control systems. (v) The manufacturer must... small volume manufacturers and small volume test groups. 86.1826-01 Section 86.1826-01 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW...

  15. 40 CFR 86.1826-01 - Assigned deterioration factors for small volume manufacturers and small volume test groups.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... durability groups) that is equipped with unproven emission control systems. (v) The manufacturer must... small volume manufacturers and small volume test groups. 86.1826-01 Section 86.1826-01 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW...

  16. 40 CFR 86.1826-01 - Assigned deterioration factors for small volume manufacturers and small volume test groups.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... durability groups) that is equipped with unproven emission control systems. (v) The manufacturer must... small volume manufacturers and small volume test groups. 86.1826-01 Section 86.1826-01 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW...

  17. 40 CFR 86.1826-01 - Assigned deterioration factors for small volume manufacturers and small volume test groups.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... durability groups) that is equipped with unproven emission control systems. (v) The manufacturer must... small volume manufacturers and small volume test groups. 86.1826-01 Section 86.1826-01 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW...

  18. Quantification of myo-inositol, 1,5-anhydro-D-sorbitol, and D-chiro-inositol using high-performance liquid chromatography with electrochemical detection in very small volume clinical samples

    PubMed Central

    Schimpf, Karen J.; Meek, Claudia C.; Leff, Richard D.; Phelps, Dale L.; Schmitz, Daniel J.; Cordle, Christopher T.

    2015-01-01

    Inositol is a six-carbon sugar alcohol and is one of nine biologically significant isomers of hexahydroxycyclohexane. Myo-inositol is the primary biologically active form and is present in higher concentrations in the fetus and newborn than in adults. It is currently being examined for the prevention of retinopathy of prematurity in newborn preterm infants. A robust method for quantifying myo-inositol (MI), D-chiro-inositol (DCI) and 1,5-anhydro-D-sorbitol (ADS) in very small-volume (25 μL) urine, blood serum and/or plasma samples was developed. Using a multiple-column, multiple mobile phase liquid chromatographic system with electrochemical detection, the method was validated with respect to (a) selectivity, (b) accuracy/recovery, (c) precision/reproducibility, (d) sensitivity, (e) stability and (f) ruggedness. The standard curve was linear and ranged from 0.5 to 30 mg/L for each of the three analytes. Above-mentioned performance measures were within acceptable limits described in the Food and Drug Administration’s Guidance for Industry: Bioanalytical Method Validation. The method was validated using blood serum and plasma collected using four common anticoagulants, and also by quantifying the accuracy and sensitivity of MI measured in simulated urine samples recovered from preterm infant diaper systems. The method performs satisfactorily measuring the three most common inositol isomers on 25 μL clinical samples of serum, plasma milk, and/or urine. Similar performance is seen testing larger volume samples of infant formulas and infant formula ingredients. MI, ADS and DCI may be accurately tested in urine samples collected from five different preterm infant diapers if the urine volume is greater than 2–5 mL. PMID:26010453

  19. Magnetic particles as liquid carriers in the microfluidic lab-in-tube approach to detect phase change.

    PubMed

    Blumenschein, Nicholas A; Han, Daewoo; Caggioni, Marco; Steckl, Andrew J

    2014-06-11

    Magnetic beads (MBs) with ∼1.9 μm average diameter were used to transport specific microliter-scale volumes of liquids between adjacent reservoirs within a closed tube under the influence of a magnetic field. The tube's inner surface is coated with a hydrophobic layer, enabling the formation of a surface tension valve by inserting an air gap between reservoirs. This transfer process was implemented by keeping the MBs stationary with a fixed external magnet while the liquid reservoirs were translated by a computer-controlled syringe pump system. The magnet induces the aggregation of MBs in a loosely packed cluster (void volume ∼90-95%) against the tube's inner wall. The liquid trapped in the MB cluster is transported across the air gap between reservoirs. Fluorescence intensity from a dye placed in one reservoir is used to measure the volume of liquid transferred between reservoirs. The carry-over liquid volume is controlled by the mass of the MBs within the device. The typical volume of liquid carried by the MB cluster is ∼2 to 3 μL/mg of beads, allowing the use of small samples. This technique can be used to study the effect of small compositional variation on the properties of fluid mixtures. The feasibility of this "lab-in-tube" approach for binary phase diagram determination in a water-surfactant (C12E5) system was demonstrated.

  20. Impact of computed tomography and {sup 18}F-deoxyglucose coincidence detection emission tomography image fusion for optimization of conformal radiotherapy in non-small-cell lung cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deniaud-Alexandre, Elisabeth; Touboul, Emmanuel; Lerouge, Delphine

    2005-12-01

    Purpose: To report a retrospective study concerning the impact of fused {sup 18}F-fluoro-deoxy-D-glucose (FDG)-hybrid positron emission tomography (PET) and CT images on three-dimensional conformal radiotherapy planning for patients with non-small-cell lung cancer. Methods and Materials: A total of 101 patients consecutively treated for Stage I-III non-small-cell lung cancer were studied. Each patient underwent CT and FDG-hybrid PET for simulation treatment in the same treatment position. Images were coregistered using five fiducial markers. Target volume delineation was initially performed on the CT images, and the corresponding FDG-PET data were subsequently used as an overlay to the CT data to define themore » target volume. Results: {sup 18}F-fluoro-deoxy-D-glucose-PET identified previously undetected distant metastatic disease in 8 patients, making them ineligible for curative conformal radiotherapy (1 patient presented with some positive uptake corresponding to concomitant pulmonary tuberculosis). Another patient was ineligible for curative treatment because the fused PET-CT images demonstrated excessively extensive intrathoracic disease. The gross tumor volume (GTV) was decreased by CT-PET image fusion in 21 patients (23%) and was increased in 24 patients (26%). The GTV reduction was {>=}25% in 7 patients because CT-PET image fusion reduced the pulmonary GTV in 6 patients (3 patients with atelectasis) and the mediastinal nodal GTV in 1 patient. The GTV increase was {>=}25% in 14 patients owing to an increase in the pulmonary GTV in 11 patients (4 patients with atelectasis) and detection of occult mediastinal lymph node involvement in 3 patients. Of 81 patients receiving a total dose of {>=}60 Gy at the International Commission on Radiation Units and Measurements point, after CT-PET image fusion, the percentage of total lung volume receiving >20 Gy increased in 15 cases and decreased in 22. The percentage of total heart volume receiving >36 Gy increased in 8 patients and decreased in 14. The spinal cord volume receiving at least 45 Gy (2 patients) decreased. Multivariate analysis showed that tumor with atelectasis was the single independent factor that resulted in a significant effect on the modification of the size of the GTV by FDG-PET: tumor with atelectasis (with vs. without atelectasis, p = 0.0001). Conclusion: The results of our study have confirmed that integrated hybrid PET/CT in the treatment position and coregistered images have an impact on treatment planning and management of non-small-cell lung cancer. However, FDG images using dedicated PET scanners and respiration-gated acquisition protocols could improve the PET-CT image coregistration. Furthermore, the impact on treatment outcome remains to be demonstrated.« less

  1. Lung volume quantified by MRI reflects extracellular-matrix deposition and altered pulmonary function in bleomycin models of fibrosis: effects of SOM230.

    PubMed

    Egger, Christine; Gérard, Christelle; Vidotto, Nella; Accart, Nathalie; Cannet, Catherine; Dunbar, Andrew; Tigani, Bruno; Piaia, Alessandro; Jarai, Gabor; Jarman, Elizabeth; Schmid, Herbert A; Beckmann, Nicolau

    2014-06-15

    Idiopathic pulmonary fibrosis is a progressive and lethal disease, characterized by loss of lung elasticity and alveolar surface area, secondary to alveolar epithelial cell injury, reactive inflammation, proliferation of fibroblasts, and deposition of extracellular matrix. The effects of oropharyngeal aspiration of bleomycin in Sprague-Dawley rats and C57BL/6 mice, as well as of intratracheal administration of ovalbumin to actively sensitized Brown Norway rats on total lung volume as assessed noninvasively by magnetic resonance imaging (MRI) were investigated here. Lung injury and volume were quantified by using nongated or respiratory-gated MRI acquisitions [ultrashort echo time (UTE) or gradient-echo techniques]. Lung function of bleomycin-challenged rats was examined additionally using a flexiVent system. Postmortem analyses included histology of collagen and hydroxyproline assays. Bleomycin induced an increase of MRI-assessed total lung volume, lung dry and wet weights, and hydroxyproline content as well as collagen amount. In bleomycin-treated rats, gated MRI showed an increased volume of the lung in the inspiratory and expiratory phases of the respiratory cycle and a temporary decrease of tidal volume. Decreased dynamic lung compliance was found in bleomycin-challenged rats. Bleomycin-induced increase of MRI-detected lung volume was consistent with tissue deposition during fibrotic processes resulting in decreased lung elasticity, whereas influences by edema or emphysema could be excluded. In ovalbumin-challenged rats, total lung volume quantified by MRI remained unchanged. The somatostatin analog, SOM230, was shown to have therapeutic effects on established bleomycin-induced fibrosis in rats. This work suggests MRI-detected total lung volume as readout for tissue-deposition in small rodent bleomycin models of pulmonary fibrosis. Copyright © 2014 the American Physiological Society.

  2. First Order Statistics of Speckle around a Scatterer Volume Density Edge and Edge Detection in Ultrasound Images.

    NASA Astrophysics Data System (ADS)

    Li, Yue

    1990-01-01

    Ultrasonic imaging plays an important role in medical imaging. But the images exhibit a granular structure, commonly known as speckle. The speckle tends to mask the presence of low-contrast lesions and reduces the ability of a human observer to resolve fine details. Our interest in this research is to examine the problem of edge detection and come up with methods for improving the visualization of organ boundaries and tissue inhomogeneity edges. An edge in an image can be formed either by acoustic impedance change or by scatterer volume density change (or both). The echo produced from these two kinds of edges has different properties. In this work, it has been proved that the echo from a scatterer volume density edge is the Hilbert transform of the echo from a rough impedance boundary (except for a constant) under certain conditions. This result can be used for choosing the correct signal to transmit to optimize the performance of edge detectors and characterizing an edge. The signal to noise ratio of the echo produced by a scatterer volume density edge is also obtained. It is found that: (1) By transmitting a signal with high bandwidth ratio and low center frequency, one can obtain a higher signal to noise ratio. (2) For large area edges, the farther the transducer is from the edge, the larger is the signal to noise ratio. But for small area edges, the nearer the transducer is to the edge, the larger is the signal to noise ratio. These results enable us to maximize the signal to noise ratio by adjusting these parameters. (3) The signal to noise ratio is not only related to the ratio of scatterer volume densities at the edge, but also related to the absolute value of scatterer volume densities. Some of these results have been proved through simulation and experiment. Different edge detection methods have been used to detect simulated scatterer volume density edges to compare their performance. A so-called interlaced array method has been developed for speckle reduction in the images formed by synthetic aperture focussing technique, and experiments have been done to evaluate its performance.

  3. Digital stereophotogrammetry based on circular markers and zooming cameras: evaluation of a method for 3D analysis of small motions in orthopaedic research

    PubMed Central

    2011-01-01

    Background Orthopaedic research projects focusing on small displacements in a small measurement volume require a radiation free, three dimensional motion analysis system. A stereophotogrammetrical motion analysis system can track wireless, small, light-weight markers attached to the objects. Thereby the disturbance of the measured objects through the marker tracking can be kept at minimum. The purpose of this study was to develop and evaluate a non-position fixed compact motion analysis system configured for a small measurement volume and able to zoom while tracking small round flat markers in respect to a fiducial marker which was used for the camera pose estimation. Methods The system consisted of two web cameras and the fiducial marker placed in front of them. The markers to track were black circles on a white background. The algorithm to detect a centre of the projected circle on the image plane was described and applied. In order to evaluate the accuracy (mean measurement error) and precision (standard deviation of the measurement error) of the optical measurement system, two experiments were performed: 1) inter-marker distance measurement and 2) marker displacement measurement. Results The first experiment of the 10 mm distances measurement showed a total accuracy of 0.0086 mm and precision of ± 0.1002 mm. In the second experiment, translations from 0.5 mm to 5 mm were measured with total accuracy of 0.0038 mm and precision of ± 0.0461 mm. The rotations of 2.25° amount were measured with the entire accuracy of 0.058° and the precision was of ± 0.172°. Conclusions The description of the non-proprietary measurement device with very good levels of accuracy and precision may provide opportunities for new, cost effective applications of stereophotogrammetrical analysis in musculoskeletal research projects, focusing on kinematics of small displacements in a small measurement volume. PMID:21284867

  4. [Development of a continuous blood pressure monitoring and recording system].

    PubMed

    Zhang, Yang; Li, Yong; Gao, Shumei; Song, Yilin

    2012-09-01

    A small experimental system is constructed with working principle of continuous blood pressure monitoring based on the volume compensation method. The preliminary experimental results show that the system can collect blood pressure signals at the radial artery effectively. The digital PID algorithm can track the variation of blood pressure. And the accuracy of continuous blood pressure detecting achieve the level of same kind of product.

  5. Optical Mass Gauging System for Measuring Liquid Levels in a Reduced Gravity Environment

    NASA Technical Reports Server (NTRS)

    Sullenberger, Ryan M.; Munoz, Wesley M.; Lyon, Matt P.; Vogel, Kenny; Yalin, Azer P.; Korman, Valentin; Polzin, Kurt A.

    2010-01-01

    A compact and rugged fiber-coupled liquid volume sensor designed for flight on a sounding rocket platform is presented. The sensor consists of a Mach-Zehnder interferometer capable of measuring the amount of liquid contained in a tank under any gravitational conditions, including a microgravity environment, by detecting small changes in the index of refraction of the gas contained within a sensing region. By monitoring changes in the interference fringe pattern as the system undergoes a small compression provided by a piston, the ullage volume of a tank can be directly measured allowing for a determination of the liquid volume. To demonstrate the technique, data are acquired using two tanks containing different volumes of liquid, which are representative of the levels of liquid in a tank at different time periods during a mission. The two tanks are independently exposed to the measurement apparatus, allowing for a determination of the liquid level in each. In a controlled, laboratory test of the unit, the system demonstrated a capability of measuring a liquid level in an individual tank of 10.53 mL with a 2% error. The overall random uncertainty for the flight system is higher than that one test, at +/- 1.5 mL.

  6. Application of imaging fusion combining contrast-enhanced ultrasound and magnetic resonance imaging in detection of hepatic cellular carcinomas undetectable by conventional ultrasound.

    PubMed

    Dong, Yi; Wang, Wen-Ping; Mao, Feng; Ji, Zheng-Biao; Huang, Bei-Jian

    2016-04-01

    The aim of this study is to explore the value of volume navigation image fusion-assisted contrast-enhanced ultrasound (CEUS) in detection for radiofrequency ablation guidance of hepatocellular carcinomas (HCCs), which were undetectable on conventional ultrasound. From May 2012 to May 2014, 41 patients with 49 HCCs were included in this study. All lesions were detected by dynamic magnetic resonance imaging (MRI) and planned for radiofrequency ablation but were undetectable on conventional ultrasound. After a bolus injection of 2.4 ml SonoVue® (Bracco, Italy), LOGIQ E9 ultrasound system with volume navigation system (version R1.0.5, GE Healthcare, Milwaukee, WI, USA) was used to fuse CEUS and MRI images. The fusion time, fusion success rate, lesion enhancement pattern, and detection rate were analyzed. Image fusions were conducted successfully in 49 HCCs, the technical success rate was 100%. The average fusion time was (9.2 ± 2.1) min (6-12 min). The mean diameter of HCCs was 25.2 ± 5.3 mm (mean ± SD), and mean depth was 41.8 ± 17.2 mm. The detection rate of HCCs using CEUS/MRI imaging fusion (95.9%, 47/49) was significantly higher than CEUS (42.9%, 21/49) (P < 0.05). For small HCCs (diameter, 1-2 cm), the detection rate using imaging fusion (96.9%, 32/33) was also significantly higher than CEUS (18.2%, 6/33) (P < 0.01). All HCCs displayed a rapid wash-in pattern in the arterial phase of CEUS. Imaging fusion combining CEUS and MRI is a promising technique to improve the detection, precise localization, and accurate diagnosis of undetectable HCCs on conventional ultrasound, especially small and atypical HCCs. © 2015 Journal of Gastroenterology and Hepatology Foundation and John Wiley & Sons Australia, Ltd.

  7. Cone-beam volume CT mammographic imaging: feasibility study

    NASA Astrophysics Data System (ADS)

    Chen, Biao; Ning, Ruola

    2001-06-01

    X-ray projection mammography, using a film/screen combination or digital techniques, has proven to be the most effective imaging modality for early detection of breast cancer currently available. However, the inherent superimposition of structures makes small carcinoma (a few millimeters in size) difficult to detect in the occultation case or in dense breasts, resulting in a high false positive biopsy rate. The cone-beam x-ray projection based volume imaging using flat panel detectors (FPDs) makes it possible to obtain three-dimensional breast images. This may benefit diagnosis of the structure and pattern of the lesion while eliminating hard compression of the breast. This paper presents a novel cone-beam volume CT mammographic imaging protocol based on the above techniques. Through computer simulation, the key issues of the system and imaging techniques, including the x-ray imaging geometry and corresponding reconstruction algorithms, x-ray characteristics of breast tissues, x-ray setting techniques, the absorbed dose estimation and the quantitative effect of x-ray scattering on image quality, are addressed. The preliminary simulation results support the proposed cone-beam volume CT mammographic imaging modality in respect to feasibility and practicability for mammography. The absorbed dose level is comparable to that of current two-view mammography and would not be a prominent problem for this imaging protocol. Compared to traditional mammography, the proposed imaging protocol with isotropic spatial resolution will potentially provide significantly better low contrast detectability of breast tumors and more accurate location of breast lesions.

  8. Assessment of Uncertainty-Based Screening Volumes for NASA Robotic LEO and GEO Conjunction Risk Assessment

    NASA Technical Reports Server (NTRS)

    Narvet, Steven W.; Frigm, Ryan C.; Hejduk, Matthew D.

    2011-01-01

    Conjunction Assessment operations require screening assets against the space object catalog by placing a pre-determined spatial volume around each asset and predicting when another object will violate that volume. The selection of the screening volume used for each spacecraft is a trade-off between observing all conjunction events that may pose a potential risk to the primary spacecraft and the ability to analyze those predicted events. If the screening volumes are larger, then more conjunctions can be observed and therefore the probability of a missed detection of a high risk conjunction event is small; however, the amount of data which needs to be analyzed increases. This paper characterizes the sensitivity of screening volume size to capturing typical orbit uncertainties and the expected number of conjunction events observed. These sensitivities are quantified in the form of a trade space that allows for selection of appropriate screen-ing volumes to fit the desired concept of operations, system limitations, and tolerable analyst workloads. This analysis will specifically highlight the screening volume determination and selection process for use in the NASA Conjunction Assessment Risk Analysis process but will also provide a general framework for other Owner / Operators faced with similar decisions.

  9. High-Collection-Efficiency Fluorescence Detection Cell

    NASA Technical Reports Server (NTRS)

    Hanisco, Thomas; Cazorla, Maria; Swanson, Andrew

    2013-01-01

    A new fluorescence cell has been developed for the laser induced fluorescence (LIF) detection of formaldehyde. The cell is used to sample a flow of air that contains trace concentrations of formaldehyde. The cell provides a hermetically sealed volume in which a flow of air containing formaldehyde can be illuminated by a laser. The cell includes the optics for transmitting the laser beam that is used to excite the formaldehyde and for collecting the resulting fluorescence. The novelty of the cell is its small size and simple design that provides a more robust and cheaper alternative to the state of the art. Despite its simplicity, the cell provides the same sensitivity to detection as larger, more complicated cells.

  10. Role of computed tomography angiography in detection and staging of small bowel carcinoid tumors

    PubMed Central

    Bonekamp, David; Raman, Siva P; Horton, Karen M; Fishman, Elliot K

    2015-01-01

    Small-bowel carcinoid tumors are the most common form (42%) of gastrointestinal carcinoids, which by themselves comprise 70% of neuroendocrine tumors. Although primary small bowel neoplasms are overall rare (3%-6% of all gastrointestinal neoplasms), carcinoids still represent the second most common (20%-30%) primary small-bowel malignancy after small bowel adenocarcinoma. Their imaging evaluation is often challenging. State-of-the-art high-resolution multiphasic computed tomography together with advanced postprocessing methods provides an excellent tool for their depiction. The manifold interactive parameter choices however require knowledge of when to use which technique. Here, we discuss the imaging appearance and evaluation of duodenal, jejunal and ileal carcinoid tumors, including the imaging features of the primary tumor, locoregional mesenteric nodal metastases, and distant metastatic disease. A protocol for optimal lesion detection is presented, including the use of computed tomography enterography, volume acquisition, computed tomography angiography and three-dimensional mapping. Imaging findings are illustrated with a series of challenging cases which illustrate the spectrum of possible disease in the small bowel and mesentery, the range of possible appearances in the bowel itself on multiphase data and extraluminal findings such as the desmoplastic reaction in mesentery and hypervascular liver metastases. Typical imaging pitfalls and pearls are illustrated. PMID:26435774

  11. Solution nuclear magnetic resonance spectroscopy on a nanostructured diamond chip.

    PubMed

    Kehayias, P; Jarmola, A; Mosavian, N; Fescenko, I; Benito, F M; Laraoui, A; Smits, J; Bougas, L; Budker, D; Neumann, A; Brueck, S R J; Acosta, V M

    2017-08-04

    Sensors using nitrogen-vacancy centers in diamond are a promising tool for small-volume nuclear magnetic resonance (NMR) spectroscopy, but the limited sensitivity remains a challenge. Here we show nearly two orders of magnitude improvement in concentration sensitivity over previous nitrogen-vacancy and picoliter NMR studies. We demonstrate NMR spectroscopy of picoliter-volume solutions using a nanostructured diamond chip with dense, high-aspect-ratio nanogratings, enhancing the surface area by 15 times. The nanograting sidewalls are doped with nitrogen-vacancies located a few nanometers from the diamond surface to detect the NMR spectrum of roughly 1 pl of fluid lying within adjacent nanograting grooves. We perform 1 H and 19 F nuclear magnetic resonance spectroscopy at room temperature in magnetic fields below 50 mT. Using a solution of CsF in glycerol, we determine that 4 ± 2 × 10 12 19 F spins in a 1 pl volume can be detected with a signal-to-noise ratio of 3 in 1 s of integration.Nitrogen vacancy (NV) centres in diamond can be used for NMR spectroscopy, but increased sensitivity is needed to avoid long measurement times. Kehayias et al. present a nanostructured diamond grating with a high density of NV centres, enabling NMR spectroscopy of picoliter-volume solutions.

  12. Optimization of Evans blue quantitation in limited rat tissue samples

    PubMed Central

    Wang, Hwai-Lee; Lai, Ted Weita

    2014-01-01

    Evans blue dye (EBD) is an inert tracer that measures plasma volume in human subjects and vascular permeability in animal models. Quantitation of EBD can be difficult when dye concentration in the sample is limited, such as when extravasated dye is measured in the blood-brain barrier (BBB) intact brain. The procedure described here used a very small volume (30 µl) per sample replicate, which enabled high-throughput measurements of the EBD concentration based on a standard 96-well plate reader. First, ethanol ensured a consistent optic path length in each well and substantially enhanced the sensitivity of EBD fluorescence spectroscopy. Second, trichloroacetic acid (TCA) removed false-positive EBD measurements as a result of biological solutes and partially extracted EBD into the supernatant. Moreover, a 1:2 volume ratio of 50% TCA ([TCA final] = 33.3%) optimally extracted EBD from the rat plasma protein-EBD complex in vitro and in vivo, and 1:2 and 1:3 weight-volume ratios of 50% TCA optimally extracted extravasated EBD from the rat brain and liver, respectively, in vivo. This procedure is particularly useful in the detection of EBD extravasation into the BBB-intact brain, but it can also be applied to detect dye extravasation into tissues where vascular permeability is less limiting. PMID:25300427

  13. Optimization of Evans blue quantitation in limited rat tissue samples

    NASA Astrophysics Data System (ADS)

    Wang, Hwai-Lee; Lai, Ted Weita

    2014-10-01

    Evans blue dye (EBD) is an inert tracer that measures plasma volume in human subjects and vascular permeability in animal models. Quantitation of EBD can be difficult when dye concentration in the sample is limited, such as when extravasated dye is measured in the blood-brain barrier (BBB) intact brain. The procedure described here used a very small volume (30 µl) per sample replicate, which enabled high-throughput measurements of the EBD concentration based on a standard 96-well plate reader. First, ethanol ensured a consistent optic path length in each well and substantially enhanced the sensitivity of EBD fluorescence spectroscopy. Second, trichloroacetic acid (TCA) removed false-positive EBD measurements as a result of biological solutes and partially extracted EBD into the supernatant. Moreover, a 1:2 volume ratio of 50% TCA ([TCA final] = 33.3%) optimally extracted EBD from the rat plasma protein-EBD complex in vitro and in vivo, and 1:2 and 1:3 weight-volume ratios of 50% TCA optimally extracted extravasated EBD from the rat brain and liver, respectively, in vivo. This procedure is particularly useful in the detection of EBD extravasation into the BBB-intact brain, but it can also be applied to detect dye extravasation into tissues where vascular permeability is less limiting.

  14. Sensitive analysis of steroid estrogens and bisphenol a in small volumes of water using isotope-dilution ultra-performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Chang, Hong; Shen, Xiaoyan; Shao, Bing; Wu, Fengchang

    2018-04-01

    An isotope-dilution ultra-performance liquid chromatography-electrospray tandem mass spectrometry method combined with dansylation was established to sensitively quantify four steroid estrogens (estrone, 17α-estradiol, 17β-estradiol and 17α-ethynylestradiol) and bisphenol A in sewage influent and effluent. A simple hexane extraction was performed from a small volume (10 mL), followed by dansyl chloride derivatization and purification with a silica cartridge. The method effectively reduced the matrix effects in sample extract and permitted the selective and sensitive determination of target compounds from complicated matrices. The detection limits of the method for steroid estrogens were 0.20-0.90 ng L -1 in influent and 0.10-0.20 ng L -1 in effluent samples. For bisphenol A, the limits detection of the method were 20 and 0.80 for influent and effluent samples, respectively. Recoveries of 85%-96% were observed in all matrices. The method was applied to analyze residual estrogens and bisphenol A in sewage influent and effluent samples from Beijing, China. The concentrations of bisphenol A (636-1200 ng L -1 ) were up to 250 times higher than those of steroid estrogens. Estrone was the dominant estrogen in influent and effluent samples, while similar concentrations of 17α-estradiol and 17β-estradiol were detected in all samples. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Surveillance of Vittaforma corneae in hot springs by a small-volume procedure.

    PubMed

    Chen, Jung-Sheng; Hsu, Tsui-Kang; Hsu, Bing-Mu; Huang, Tung-Yi; Huang, Yu-Li; Shaio, Men-Fang; Ji, Dar-Der

    2017-07-01

    Vittaforma corneae is an obligate intracellular fungus and can cause human ocular microsporidiosis. Although accumulating reports of V. corneae causing keratoconjunctivitis in both healthy and immunocompromised persons have been published, little is known about the organism's occurrence in aquatic environments. Limitations in detection sensitivity have meant a large sampling volume is required to detect the pathogen up to now, which is problematic. A recent study in Taiwan has shown that some individuals suffering from microsporidial keratitis (MK) were infected after exposure to the pathogen at a hot spring. As a consequence of this, a survey and analysis of environmental V. corneae present in hot springs became an urgent need. In this study, sixty water samples from six hot spring recreation areas around Taiwan were analyzed. One liter of water from each sample site was filtered to harvest the fungi. The positive samples were detected using a modified nested PCR approach followed by sequencing using specific SSU rRNA gene primer pairs for V. corneae. In total fifteen V. corneae-like isolates were identified (25.0% of sites). Among them, six isolates, which were collected from recreational areas B, C and D, were highly similar to known V. corneae keratitis strains from Taiwan and other countries. Furthermore, five isolates, which were collected from recreation areas A, C, E and F, were very similar to Vittaforma-like diarrhea strains isolated in Portugal. Cold spring water tubs and public foot bath pools had the highest detection rate (50%), suggesting that hot springs might be contaminated via untreated water sources. Comparing the detection rate across different regions of Taiwan, Taitung, which is in the east of the island, gave the highest positive rate (37.5%). Statistical analysis showed that outdoor/soil exposure and a high heterotrophic plate count (HPC) were risk factors for the occurrence of V. corneae. Our findings provide empirical evidence supporting the need for proper control and regulations at hot spring recreational waters in order to avoid health risks from this pathogen. Finally, we have developed a small volume procedure for detecting V. corneae in water samples and this has proved to be very useful. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Comparison of standard- and low-tube voltage 320-detector row volume CT angiography in detection of intracranial aneurysms with digital subtraction angiography as gold standard.

    PubMed

    Sun, Gang; Ding, Juan; Lu, Yang; Li, Min; Li, Li; Li, Guo-ying; Zhang, Xu-ping

    2012-03-01

    The aim of this study was to prospectively assess the effect of low-tube voltage (80 kVp) 320-detector row volume computed tomographic (CT) angiography (L-VCTA) in the detection of intracranial aneurysms, with three-dimensional (3D) spin digital subtraction angiography (DSA) as the gold standard. Forty-eight patients with clinically suspected subarachnoid hemorrhages were divided into two groups. One group underwent L-VCTA and DSA, while the other group underwent conventional-tube voltage (120 kVp) volume CT angiography (C-VCTA) and DSA. Vascular enhancement, image quality, detection accuracy of aneurysms, and radiation dose were compared between the two groups. For objective image quality, the L-VCTA group had higher mean vessel attenuation, correlated with higher image noise and lower signal-to-noise ratio, than the C-VCTA group. For subjective image quality, there were no significant differences between the two groups regarding scores for arterial enhancement, depiction of small arterial detail, interference of venous structures, and overall image quality scores. The mean effective dose for the L-VCTA group was significantly lower than for the C-VCTA group (0.56 ± 0.25 vs 1.84 ± 0.002 mSv), with a reduction of radiation dose of 69.73%. With 3D DSA as the reference standard, the sensitivity, specificity, and accuracy in the L-VCTA and C-VCTA groups were 94.12%, 100%, 94.4% and 100%, 100%, and 100%, respectively. In both groups, there were significant correlations for maximum aneurysm diameter measurements between volume CT angiography and 3D DSA; no statistical difference in the mean maximum diameter of each aneurysm was measured between volume CT angiography and 3D DSA. L-VCTA is helpful in detecting intracranial aneurysms, with results similar to those of 3D DSA, but at a lower radiation dose than C-VCTA. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.

  17. Design considerations of a hollow microneedle-optofluidic biosensing platform incorporating enzyme-linked assays

    NASA Astrophysics Data System (ADS)

    Ranamukhaarachchi, Sahan A.; Padeste, Celestino; Häfeli, Urs O.; Stoeber, Boris; Cadarso, Victor J.

    2018-02-01

    A hollow metallic microneedle is integrated with microfluidics and photonic components to form a microneedle-optofluidic biosensor suitable for therapeutic drug monitoring (TDM) in biological fluids, like interstitial fluid, that can be collected in a painless and minimally-invasive manner. The microneedle inner lumen surface is bio-functionalized to trap and bind target analytes on-site in a sample volume as small as 0.6 nl, and houses an enzyme-linked assay on its 0.06 mm2 wall. The optofluidic components are designed to rapidly quantify target analytes present in the sample and collected in the microneedle using a simple and sensitive absorbance scheme. This contribution describes how the biosensor components were optimized to detect in vitro streptavidin-horseradish peroxidase (Sav-HRP) as a model analyte over a large detection range (0-7.21 µM) and a very low limit of detection (60.2 nM). This biosensor utilizes the lowest analyte volume reported for TDM with microneedle technology, and presents significant avenues to improve current TDM methods for patients, by potentially eliminating blood draws for several drug candidates.

  18. High-Performance Substrates for SERS Detection via Microphotonic Photopolymer Characterization and Coating With Functionalized Hydrogels

    DTIC Science & Technology

    2006-11-26

    with controlled micro and nanostructure for highly selective, high sensitivity assays. The process was modeled and a procedure for fabricating SERS...small volumes with controlled micro and nanostructure for highly selective, high sensitivity assays. We proved the feasibility of the technique and...films templated by colloidal crystals. The control over the film structure allowed optimizing their performance for potential sensor applications. The

  19. Partitioning of body fluids in the Lake Nicaragua shark and three marine sharks.

    PubMed

    THORSON, T B

    1962-11-09

    The relative volumes of major body fluids of freshwater and marine sharks are remarkably similar in spite of the differences in external medium and in osmotic pressure of body fluids. The small differences detected are in agreement with differences reported in comparisons of freshwater and marine teleosts: a slightly higher total water content and a smiller ratio of extracellular to intracellular fluids in freshwater forms.

  20. “Nanofiltration” Enabled by Super-Absorbent Polymer Beads for Concentrating Microorganisms in Water Samples

    NASA Astrophysics Data System (ADS)

    Xie, Xing; Bahnemann, Janina; Wang, Siwen; Yang, Yang; Hoffmann, Michael R.

    2016-02-01

    Detection and quantification of pathogens in water is critical for the protection of human health and for drinking water safety and security. When the pathogen concentrations are low, large sample volumes (several liters) are needed to achieve reliable quantitative results. However, most microbial identification methods utilize relatively small sample volumes. As a consequence, a concentration step is often required to detect pathogens in natural waters. Herein, we introduce a novel water sample concentration method based on superabsorbent polymer (SAP) beads. When SAP beads swell with water, small molecules can be sorbed within the beads, but larger particles are excluded and, thus, concentrated in the residual non-sorbed water. To illustrate this approach, millimeter-sized poly(acrylamide-co-itaconic acid) (P(AM-co-IA)) beads are synthesized and successfully applied to concentrate water samples containing two model microorganisms: Escherichia coli and bacteriophage MS2. Experimental results indicate that the size of the water channel within water swollen P(AM-co-IA) hydrogel beads is on the order of several nanometers. The millimeter size coupled with a negative surface charge of the beads are shown to be critical in order to achieve high levels of concentration. This new concentration procedure is very fast, effective, scalable, and low-cost with no need for complex instrumentation.

  1. "Nanofiltration" Enabled by Super-Absorbent Polymer Beads for Concentrating Microorganisms in Water Samples.

    PubMed

    Xie, Xing; Bahnemann, Janina; Wang, Siwen; Yang, Yang; Hoffmann, Michael R

    2016-02-15

    Detection and quantification of pathogens in water is critical for the protection of human health and for drinking water safety and security. When the pathogen concentrations are low, large sample volumes (several liters) are needed to achieve reliable quantitative results. However, most microbial identification methods utilize relatively small sample volumes. As a consequence, a concentration step is often required to detect pathogens in natural waters. Herein, we introduce a novel water sample concentration method based on superabsorbent polymer (SAP) beads. When SAP beads swell with water, small molecules can be sorbed within the beads, but larger particles are excluded and, thus, concentrated in the residual non-sorbed water. To illustrate this approach, millimeter-sized poly(acrylamide-co-itaconic acid) (P(AM-co-IA)) beads are synthesized and successfully applied to concentrate water samples containing two model microorganisms: Escherichia coli and bacteriophage MS2. Experimental results indicate that the size of the water channel within water swollen P(AM-co-IA) hydrogel beads is on the order of several nanometers. The millimeter size coupled with a negative surface charge of the beads are shown to be critical in order to achieve high levels of concentration. This new concentration procedure is very fast, effective, scalable, and low-cost with no need for complex instrumentation.

  2. “Nanofiltration” Enabled by Super-Absorbent Polymer Beads for Concentrating Microorganisms in Water Samples

    PubMed Central

    Xie, Xing; Bahnemann, Janina; Wang, Siwen; Yang, Yang; Hoffmann, Michael R.

    2016-01-01

    Detection and quantification of pathogens in water is critical for the protection of human health and for drinking water safety and security. When the pathogen concentrations are low, large sample volumes (several liters) are needed to achieve reliable quantitative results. However, most microbial identification methods utilize relatively small sample volumes. As a consequence, a concentration step is often required to detect pathogens in natural waters. Herein, we introduce a novel water sample concentration method based on superabsorbent polymer (SAP) beads. When SAP beads swell with water, small molecules can be sorbed within the beads, but larger particles are excluded and, thus, concentrated in the residual non-sorbed water. To illustrate this approach, millimeter-sized poly(acrylamide-co-itaconic acid) (P(AM-co-IA)) beads are synthesized and successfully applied to concentrate water samples containing two model microorganisms: Escherichia coli and bacteriophage MS2. Experimental results indicate that the size of the water channel within water swollen P(AM-co-IA) hydrogel beads is on the order of several nanometers. The millimeter size coupled with a negative surface charge of the beads are shown to be critical in order to achieve high levels of concentration. This new concentration procedure is very fast, effective, scalable, and low-cost with no need for complex instrumentation. PMID:26876979

  3. Childhood-Onset Asthma in Smokers. Association between CT Measures of Airway Size, Lung Function, and Chronic Airflow Obstruction

    PubMed Central

    Hardin, Megan E.; Come, Carolyn E.; San José Estépar, Raúl; Ross, James C.; Kurugol, Sila; Okajima, Yuka; Han, MeiLan K.; Kim, Victor; Ramsdell, Joe; Silverman, Edwin K.; Crapo, James D.; Lynch, David A.; Make, Barry; Barr, R. Graham; Hersh, Craig P.; Washko, George R.

    2014-01-01

    Rationale and Objectives: Asthma is associated with chronic airflow obstruction. Our goal was to assess the association of computed tomographic measures of airway wall volume and lumen volume with the FEV1 and chronic airflow obstruction in smokers with childhood-onset asthma. Methods: We analyzed clinical, lung function, and volumetric computed tomographic airway volume data from 7,266 smokers, including 590 with childhood-onset asthma. Small wall volume and small lumen volume of segmental airways were defined as measures 1 SD below the mean. We assessed the association between small wall volume, small lumen volume, FEV1, and chronic airflow obstruction (post-bronchodilator FEV1/FVC ratio < 0.7) using linear and logistic models. Measurements and Main Results: Compared with subjects without childhood-onset asthma, those with childhood-onset asthma had smaller wall volume and lumen volume (P < 0.0001) of segmental airways. Among subjects with childhood-onset asthma, those with the smallest wall volume and lumen volume had the lowest FEV1 and greatest odds of chronic airflow obstruction. A similar tendency was seen in those without childhood-onset asthma. When comparing these two groups, both small wall volume and small lumen volume were more strongly associated with FEV1 and chronic airflow obstruction among subjects with childhood-asthma in multivariate models. Conclusion: In smokers with childhood-onset asthma, smaller airways are associated with reduced lung function and chronic airflow obstruction. Clinical trial registered with www.clinicaltrials.gov (NCT00608764). PMID:25296268

  4. Childhood-onset asthma in smokers. association between CT measures of airway size, lung function, and chronic airflow obstruction.

    PubMed

    Diaz, Alejandro A; Hardin, Megan E; Come, Carolyn E; San José Estépar, Raúl; Ross, James C; Kurugol, Sila; Okajima, Yuka; Han, MeiLan K; Kim, Victor; Ramsdell, Joe; Silverman, Edwin K; Crapo, James D; Lynch, David A; Make, Barry; Barr, R Graham; Hersh, Craig P; Washko, George R

    2014-11-01

    Asthma is associated with chronic airflow obstruction. Our goal was to assess the association of computed tomographic measures of airway wall volume and lumen volume with the FEV1 and chronic airflow obstruction in smokers with childhood-onset asthma. We analyzed clinical, lung function, and volumetric computed tomographic airway volume data from 7,266 smokers, including 590 with childhood-onset asthma. Small wall volume and small lumen volume of segmental airways were defined as measures 1 SD below the mean. We assessed the association between small wall volume, small lumen volume, FEV1, and chronic airflow obstruction (post-bronchodilator FEV1/FVC ratio < 0.7) using linear and logistic models. Compared with subjects without childhood-onset asthma, those with childhood-onset asthma had smaller wall volume and lumen volume (P < 0.0001) of segmental airways. Among subjects with childhood-onset asthma, those with the smallest wall volume and lumen volume had the lowest FEV1 and greatest odds of chronic airflow obstruction. A similar tendency was seen in those without childhood-onset asthma. When comparing these two groups, both small wall volume and small lumen volume were more strongly associated with FEV1 and chronic airflow obstruction among subjects with childhood-asthma in multivariate models. In smokers with childhood-onset asthma, smaller airways are associated with reduced lung function and chronic airflow obstruction. Clinical trial registered with www.clinicaltrials.gov (NCT00608764).

  5. Automated Propulsion Data Screening demonstration system

    NASA Technical Reports Server (NTRS)

    Hoyt, W. Andes; Choate, Timothy D.; Whitehead, Bruce A.

    1995-01-01

    A fully-instrumented firing of a propulsion system typically generates a very large quantity of data. In the case of the Space Shuttle Main Engine (SSME), data analysis from ground tests and flights is currently a labor-intensive process. Human experts spend a great deal of time examining the large volume of sensor data generated by each engine firing. These experts look for any anomalies in the data which might indicate engine conditions warranting further investigation. The contract effort was to develop a 'first-cut' screening system for application to SSME engine firings that would identify the relatively small volume of data which is unusual or anomalous in some way. With such a system, limited and expensive human resources could focus on this small volume of unusual data for thorough analysis. The overall project objective was to develop a fully operational Automated Propulsion Data Screening (APDS) system with the capability of detecting significant trends and anomalies in transient and steady-state data. However, the effort limited screening of transient data to ground test data for throttle-down cases typical of the 3-g acceleration, and for engine throttling required to reach the maximum dynamic pressure limits imposed on the Space Shuttle. This APDS is based on neural networks designed to detect anomalies in propulsion system data that are not part of the data used for neural network training. The delivered system allows engineers to build their own screening sets for application to completed or planned firings of the SSME. ERC developers also built some generic screening sets that NASA engineers could apply immediately to their data analysis efforts.

  6. Accurate high-speed liquid handling of very small biological samples.

    PubMed

    Schober, A; Günther, R; Schwienhorst, A; Döring, M; Lindemann, B F

    1993-08-01

    Molecular biology techniques require the accurate pipetting of buffers and solutions with volumes in the microliter range. Traditionally, hand-held pipetting devices are used to fulfill these requirements, but many laboratories have also introduced robotic workstations for the handling of liquids. Piston-operated pumps are commonly used in manually as well as automatically operated pipettors. These devices cannot meet the demands for extremely accurate pipetting of very small volumes at the high speed that would be necessary for certain applications (e.g., in sequencing projects with high throughput). In this paper we describe a technique for the accurate microdispensation of biochemically relevant solutions and suspensions with the aid of a piezoelectric transducer. It is suitable for liquids of a viscosity between 0.5 and 500 milliPascals. The obtainable drop sizes range from 5 picoliters to a few nanoliters with up to 10,000 drops per second. Liquids can be dispensed in single or accumulated drops to handle a wide volume range. The system proved to be excellently suitable for the handling of biological samples. It did not show any detectable negative impact on the biological function of dissolved or suspended molecules or particles.

  7. A simple high-performance liquid chromatography for the determination of linezolid in human plasma and saliva.

    PubMed

    Hara, Shuuji; Uchiyama, Masanobu; Yoshinari, Masami; Matsumoto, Taichi; Jimi, Shiro; Togawa, Atsushi; Takata, Tohru; Takamatsu, Yasushi

    2015-09-01

    Linezolid is an antimicrobial agent for the treatment of multiresistant Gram-positive infections. A practical high-performance liquid chromatography method was developed for the determination of linezolid in human plasma and saliva. Linezolid and an internal standard (o-ethoxybenzamide) were extracted from plasma and saliva with ethyl acetate and analyzed on a Capcell Pak C18 MG column with UV detection at 254 nm. The calibration curve was linear through the range 0.5-50 µg/mL using a 200 μL sample volume. The intra- and interday precisions were all <6.44% for plasma and 5.60% for saliva. The accuracies ranged from 98.8 to 110% for both matrices. The mean recoveries of linezolid were 80.8% for plasma and 79.0% for saliva. This method was used to determine the plasma and saliva concentrations of linezolid in healthy volunteers who were orally administered a 600 mg dose of linezolid. Our liquid-liquid extraction procedure is easy and requires a small volume of plasma or saliva (200 μL). This small volume can be advantageous in clinical pharmacokinetic studies, especially if children participate. Copyright © 2015 John Wiley & Sons, Ltd.

  8. Direct and long-term detection of gene doping in conventional blood samples.

    PubMed

    Beiter, T; Zimmermann, M; Fragasso, A; Hudemann, J; Niess, A M; Bitzer, M; Lauer, U M; Simon, P

    2011-03-01

    The misuse of somatic gene therapy for the purpose of enhancing athletic performance is perceived as a coming threat to the world of sports and categorized as 'gene doping'. This article describes a direct detection approach for gene doping that gives a clear yes-or-no answer based on the presence or absence of transgenic DNA in peripheral blood samples. By exploiting a priming strategy to specifically amplify intronless DNA sequences, we developed PCR protocols allowing the detection of very small amounts of transgenic DNA in genomic DNA samples to screen for six prime candidate genes. Our detection strategy was verified in a mouse model, giving positive signals from minute amounts (20 μl) of blood samples for up to 56 days following intramuscular adeno-associated virus-mediated gene transfer, one of the most likely candidate vector systems to be misused for gene doping. To make our detection strategy amenable for routine testing, we implemented a robust sample preparation and processing protocol that allows cost-efficient analysis of small human blood volumes (200 μl) with high specificity and reproducibility. The practicability and reliability of our detection strategy was validated by a screening approach including 327 blood samples taken from professional and recreational athletes under field conditions.

  9. Further analysis of clinical feasibility of OCT-based glaucoma diagnosis with Pigment epithelium central limit- Inner limit of the retina Minimal Distance (PIMD)

    NASA Astrophysics Data System (ADS)

    Söderberg, Per G.; Malmberg, Filip; Sandberg-Melin, Camilla

    2017-02-01

    The present study aimed to elucidate if comparison of angular segments of Pigment epithelium central limit- Inner limit of the retina Minimal Distance, measured over 2π radians in the frontal plane (PIMD-2π) between visits of a patient, renders sufficient precision for detection of loss of nerve fibers in the optic nerve head. An optic nerve head raster scanned cube was captured with a TOPCON 3D OCT 2000 (Topcon, Japan) device in one early to moderate stage glaucoma eye of each of 13 patients. All eyes were recorded at two visits less than 1 month apart. At each visit, 3 volumes were captured. Each volume was extracted from the OCT device for analysis. Then, angular PIMD was segmented three times over 2π radians in the frontal plane, resolved with a semi-automatic algorithm in 500 equally separated steps, PIMD-2π. It was found that individual segmentations within volumes, within visits, within subjects can be phase adjusted to each other in the frontal plane using cross-correlation. Cross correlation was also used to phase adjust volumes within visits within subjects and visits to each other within subjects. Then, PIMD-2π for each subject was split into 250 bundles of 2 adjacent PIMDs. Finally, the sources of variation for estimates of segments of PIMD-2π were derived with analysis of variance assuming a mixed model. The variation among adjacent PIMDS was found very small in relation to the variation among segmentations. The variation among visits was found insignificant in relation to the variation among volumes and the variance for segmentations was found to be on the order of 20 % of that for volumes. The estimated variances imply that, if 3 segmentations are averaged within a volume and at least 10 volumes are averaged within a visit, it is possible to estimate around a 10 % reduction of a PIMD-2π segment from baseline to a subsequent visit as significant. Considering a loss rate for a PIMD-2π segment of 23 μm/yr., 4 visits per year, and averaging 3 segmentations per volume and 3 volumes per visit, a significant reduction from baseline can be detected with a power of 80 % in about 18 months. At higher loss rate for a PIMD-2π segment, a significant difference from baseline can be detected earlier. Averaging over more volumes per visit considerably decreases the time for detection of a significant reduction of a segment of PIMD-2π. Increasing the number of segmentations averaged per visit only slightly reduces the time for detection of a significant reduction. It is concluded that phase adjustment in the frontal plane with cross correlation allows high precision estimates of a segment of PIMD-2π that imply substantially shorter followup time for detection of a significant change than mean deviation (MD) in a visual field estimated with the Humphrey perimeter or neural rim area (NRA) estimated with the Heidelberg retinal tomograph.

  10. Evaluating of small intracranial aneurysms by 64-detector CT Angiography: a comparison with 3-dimensional rotation DSA or surgical findings.

    PubMed

    Zhang, He; Hou, Chang; Zhou, Zhi; Zhang, Hao; Zhou, Gen; Zhang, Gui

    2014-01-01

    The diagnostic performance of 64-detector computed tomographic angiography (CTA) for detection of small intracranial aneurysms (SIAs) was evaluated. In this prospective study, 112 consecutive patients underwent 64-detector CTA before volume-rendering rotation digital subtraction angiography (VR-RDSA) or surgery. VR-RDSA or intraoperative findings or both were used as the gold standards. The accuracy, sensitivity, specificity, and positive predictive values (PPV) and negative predictive values (NPV), as measures to detect or rule out SIAs, were determined by patient-based and aneurysm size-based evaluations. The reference standard methods revealed 84 small aneurysms in 71 patients. The results of patient-based 64-detector CTA evaluation for SIAs were: accuracy, 98.2%; sensitivity, 98.6%; specificity, 97.6%; PPV, 98.6%; and NPV, 97.6%. The aneurysm-based evaluation results were: accuracy, 96.8%; sensitivity, 97.6%; specificity, 95.1%; PPV, 97.6%; and NPV, 95.1%. Two false-positive and two false-negative findings for aneurysms <3 mm in size occurred in the 64-detector CTA analysis. The diagnostic performance of 64-detector CTA did not improve much compared with 16-detector CTA for detecting SIAs, especially for very small aneurysms. VR-RDSA is still necessary for patients with a history of subarachnoid hemorrhage if the CTA findings are negative. Copyright © 2012 by the American Society of Neuroimaging.

  11. A newly validated high-performance liquid chromatography method with diode array ultraviolet detection for analysis of the antimalarial drug primaquine in the blood plasma.

    PubMed

    Carmo, Ana Paula Barbosa do; Borborema, Manoella; Ribeiro, Stephan; De-Oliveira, Ana Cecilia Xavier; Paumgartten, Francisco Jose Roma; Moreira, Davyson de Lima

    2017-01-01

    Primaquine (PQ) diphosphate is an 8-aminoquinoline antimalarial drug with unique therapeutic properties. It is the only drug that prevents relapses of Plasmodium vivax or Plasmodium ovale infections. In this study, a fast, sensitive, cost-effective, and robust method for the extraction and high-performance liquid chromatography with diode array ultraviolet detection (HPLC-DAD-UV ) analysis of PQ in the blood plasma was developed and validated. After plasma protein precipitation, PQ was obtained by liquid-liquid extraction and analyzed by HPLC-DAD-UV with a modified-silica cyanopropyl column (250mm × 4.6mm i.d. × 5μm) as the stationary phase and a mixture of acetonitrile and 10mM ammonium acetate buffer (pH = 3.80) (45:55) as the mobile phase. The flow rate was 1.0mL·min-1, the oven temperature was 50OC, and absorbance was measured at 264nm. The method was validated for linearity, intra-day and inter-day precision, accuracy, recovery, and robustness. The detection (LOD) and quantification (LOQ) limits were 1.0 and 3.5ng·mL-1, respectively. The method was used to analyze the plasma of female DBA-2 mice treated with 20mg.kg-1 (oral) PQ diphosphate. By combining a simple, low-cost extraction procedure with a sensitive, precise, accurate, and robust method, it was possible to analyze PQ in small volumes of plasma. The new method presents lower LOD and LOQ limits and requires a shorter analysis time and smaller plasma volumes than those of previously reported HPLC methods with DAD-UV detection. The new validated method is suitable for kinetic studies of PQ in small rodents, including mouse models for the study of malaria.

  12. [Determination of four phenolic endocrine disruptors in environmental water samples by high performance liquid chromatography-fluorescence detection using dispersive liquid-liquid microextraction coupled with derivatization].

    PubMed

    Wang, Xiaoyan; Qi, Weimei; Zhao, Xian'en; Lü, Tao; Wang, Xiya; Zheng, Longfang; Yan, Yehao; You, Jinmao

    2014-06-01

    To achieve accurate, fast and sensitive detection of phenolic endocrine disruptors in small volume of environmental water samples, a method of dispersive liquid-liquid microextraction (DLLME) coupled with fluorescent derivatization was developed for the determination of bisphenol A, nonylphenol, octylphenol and 4-tert-octylphenol in environmental water samples by high performance liquid chromatography-fluorescence detection (HPLC-FLD). The DLLME and derivatization conditions were investigated, and the optimized DLLME conditions for small volume of environmental water samples (pH 4.0) at room temperature were as follows: 70 microL chloroform as extraction solvent, 400 microL acetonitrile as dispersing solvent, vortex mixing for 3 min, and then high-speed centrifugation for 2 min. Using 2-[2-(7H-dibenzo [a, g] carbazol-7-yl)-ethoxy] ethyl chloroformate (DBCEC-Cl) as precolumn derivatization reagent, the stable derivatives of the four phenolic endocrine disruptors were obtained in pH 10.5 Na2CO3-NaHCO3 buffer/acetonitrile at 50 degrees C for 3 min, and then separated within 10 min by HPLC-FLD. The limits of detection (LODs) were in the range of 0.9-1.6 ng/L, and the limits of quantification (LOQs) were in the range of 3.8-7.1 ng/L. This method had perfect linearity, precision and recovery results, and showed obvious advantages and practicality comparing to the previously reported methods. It is a convenient and validated method for the routine analysis of phenolic endocrine disruptors in waste water of paper mill, lake water, domestic wastewater, tap water, etc.

  13. Detection and Clinical Patterns of Nephron Hypertrophy and Nephrosclerosis Among Apparently Healthy Adults.

    PubMed

    Denic, Aleksandar; Alexander, Mariam P; Kaushik, Vidhu; Lerman, Lilach O; Lieske, John C; Stegall, Mark D; Larson, Joseph J; Kremers, Walter K; Vrtiska, Terri J; Chakkera, Harini A; Poggio, Emilio D; Rule, Andrew D

    2016-07-01

    Even among ostensibly healthy adults, there is often mild pathology in the kidney. The detection of kidney microstructural variation and pathology by imaging and the clinical pattern associated with these structural findings is unclear. Cross-sectional (clinical-pathologic correlation). Living kidney donors at Mayo Clinic (Minnesota and Arizona sites) and Cleveland Clinic 2000 to 2011. Predonation kidney function, risk factors, and contrast computed tomographic scan of the kidneys. These scans were segmented for cortical volume and medullary volume, reviewed for parenchymal cysts, and scored for kidney surface roughness. Nephrosclerosis (glomerulosclerosis, interstitial fibrosis/tubular atrophy, and arteriosclerosis) and nephron size (glomerular volume, mean profile tubular area, and cortical volume per glomerulus) determined from an implantation biopsy of the kidney cortex at donation. Among 1,520 living kidney donors, nephrosclerosis associated with increased kidney surface roughness, cysts, and smaller cortical to medullary volume ratio. Larger nephron size (nephron hypertrophy) associated with larger cortical volume. Nephron hypertrophy and larger cortical volume associated with higher systolic blood pressure, glomerular filtration rate, and urine albumin excretion; larger body mass index; higher serum uric acid level; and family history of end-stage renal disease. Both nephron hypertrophy and nephrosclerosis associated with older age and mild hypertension. The net effect of both nephron hypertrophy and nephrosclerosis associating with cortical volume was that nephron hypertrophy diminished volume loss with age-related nephrosclerosis and fully negated volume loss with mild hypertension-related nephrosclerosis. Kidney donors are selected on health, restricting the spectrum of pathologic findings. Kidney biopsies in living donors are a small tissue sample leading to imprecise estimates of structural findings. Among apparently healthy adults, the microstructural findings of nephron hypertrophy and nephrosclerosis differ in their associations with kidney function, macrostructure, and risk factors. Copyright © 2016 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  14. Exploitation of immunofluorescence for the quantification and characterization of small numbers of Pasteuria endospores.

    PubMed

    Costa, Sofia R; Kerry, Brian R; Bardgett, Richard D; Davies, Keith G

    2006-12-01

    The Pasteuria group of endospore-forming bacteria has been studied as a biocontrol agent of plant-parasitic nematodes. Techniques have been developed for its detection and quantification in soil samples, and these mainly focus on observations of endospore attachment to nematodes. Characterization of Pasteuria populations has recently been performed with DNA-based techniques, which usually require the extraction of large numbers of spores. We describe a simple immunological method for the quantification and characterization of Pasteuria populations. Bayesian statistics were used to determine an extraction efficiency of 43% and a threshold of detection of 210 endospores g(-1) sand. This provided a robust means of estimating numbers of endospores in small-volume samples from a natural system. Based on visual assessment of endospore fluorescence, a quantitative method was developed to characterize endospore populations, which were shown to vary according to their host.

  15. Sensitivity of the Saline Load Test for Traumatic Arthrotomy of the Ankle With Ankle Arthroscopy Simulation.

    PubMed

    Bohl, Daniel D; Frank, Rachel M; Lee, Simon; Hamid, Kamran S; Holmes, George B; Lin, Johnny; Lee, Simon

    2018-06-01

    The saline load test has been used to evaluate for traumatic arthrotomy in orthopedics. The purpose of this study was to determine the volume of saline required to detect traumatic arthrotomy of the ankle. Forty-two patients undergoing elective ankle arthroscopy were prospectively enrolled. For each patient, a standard 4-mm anteromedial portal was established. Next, an 18-gauge needle was inserted at the site of the anterolateral portal. Sterile saline was slowly injected through the needle until saline extravasated from the anteromedial portal. Saline volumes at the time of extravasation were recorded and analyzed. The saline volume required to achieve extravasation ranged from 0.2 to 60.0 mL. The median saline volume required to achieve extravasation was 9.7 mL (interquartile range, 3.8-29.6 mL); however, 5 of 42 patients required volumes between 50.0 and 60.0 mL. A total of 50.0 mL was required to achieve 90% sensitivity, 55.0 mL to achieve 95% sensitivity, and 60.0 mL to achieve 99% sensitivity. The previously recommended 30 mL of saline required to reliably detect traumatic arthrotomy of the ankle may be too small a volume. The present study suggests that clinicians should attempt to inject 60 mL of saline to effectively rule out a traumatic arthrotomy injury. Because of the study's methods involving an anteromedial arthrotomy with anterolateral saline injection, these findings may be most valid for arthrotomies on the medial side of the ankle.

  16. 40 CFR 1051.635 - What provisions apply to new manufacturers that are small businesses?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Act. For example, we may place sales limits on companies that we designate to be small-volume....201) that manufactures recreational vehicles, but does not otherwise qualify for the small-volume manufacturer provisions of this part, you may ask us to designate you to be a small-volume manufacturer. You...

  17. Rapid analysis of aflatoxins B1, B2, and ochratoxin A in rice samples using dispersive liquid-liquid microextraction combined with HPLC.

    PubMed

    Lai, Xian-Wen; Sun, Dai-Li; Ruan, Chun-Qiang; Zhang, He; Liu, Cheng-Lan

    2014-01-01

    A novel, simple, and rapid method is presented for the analysis of aflatoxin B1, aflatoxin B2, and ochratoxin A in rice samples by dispersive liquid-liquid microextraction combined with LC and fluorescence detection. After extraction of the rice samples with a mixture of acetonitrile/water/acetic acid, mycotoxins were rapidly partitioned into a small volume of organic solvent (chloroform) by dispersive liquid-liquid microextraction. The three mycotoxins were simultaneously determined by LC with fluorescence detection after precolumn derivatization for aflatoxin B1 and B2. Parameters affecting both extraction and dispersive liquid-liquid microextraction procedures, including the extraction solvent, the type and volume of extractant, the volume of dispersive solvent, the addition of salt, the pH and the extraction time, were optimized. The optimized protocol provided an enrichment factor of approximately 1.25 and with detection of limits (0.06-0.5 μg/kg) below the maximum levels imposed by current regulations for aflatoxins and ochratoxin A. The mean recovery of three mycotoxins ranged from 82.9-112%, with a RSD less than 7.9% in all cases. The method was successfully applied to measure mycotoxins in commercial rice samples collected from local supermarkets in China. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. 40 CFR 80.1622 - Approval for small refiner and small volume refinery status.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... appropriate data to correct the record when the company submits its application. (ii) Foreign small refiners... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Approval for small refiner and small... Approval for small refiner and small volume refinery status. (a) Applications for small refiner or small...

  19. Quantifying the performance of in vivo portal dosimetry in detecting four types of treatment parameter variations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bojechko, C.; Ford, E. C., E-mail: eford@uw.edu

    Purpose: To quantify the ability of electronic portal imaging device (EPID) dosimetry used during treatment (in vivo) in detecting variations that can occur in the course of patient treatment. Methods: Images of transmitted radiation from in vivo EPID measurements were converted to a 2D planar dose at isocenter and compared to the treatment planning dose using a prototype software system. Using the treatment planning system (TPS), four different types of variability were modeled: overall dose scaling, shifting the positions of the multileaf collimator (MLC) leaves, shifting of the patient position, and changes in the patient body contour. The gamma passmore » rate was calculated for the modified and unmodified plans and used to construct a receiver operator characteristic (ROC) curve to assess the detectability of the different parameter variations. The detectability is given by the area under the ROC curve (AUC). The TPS was also used to calculate the impact of the variations on the target dose–volume histogram. Results: Nine intensity modulation radiation therapy plans were measured for four different anatomical sites consisting of 70 separate fields. Results show that in vivo EPID dosimetry was most sensitive to variations in the machine output, AUC = 0.70 − 0.94, changes in patient body habitus, AUC = 0.67 − 0.88, and systematic shifts in the MLC bank positions, AUC = 0.59 − 0.82. These deviations are expected to have a relatively small clinical impact [planning target volume (PTV) D{sub 99} change <7%]. Larger variations have even higher detectability. Displacements in the patient’s position and random variations in MLC leaf positions were not readily detectable, AUC < 0.64. The D{sub 99} of the PTV changed by up to 57% for the patient position shifts considered here. Conclusions: In vivo EPID dosimetry is able to detect relatively small variations in overall dose, systematic shifts of the MLC’s, and changes in the patient habitus. Shifts in the patient’s position which can introduce large changes in the target dose coverage were not readily detected.« less

  20. Microvolume index of refraction determinations by interferometric backscatter

    NASA Astrophysics Data System (ADS)

    Bornhop, Darryl J.

    1995-06-01

    A new method has been applied to the determination of fluid bulk properties in small detection volumes. Through the use of an unfocused He-Ne laser beam and a cylindrical tube of capillary dimensions, relative refractive-index measurements are possible. The backscattered light from the illumination of a tube of capillary dimensions produces an interference pattern that is spatially defined and that contains information related to the bulk properties of the fluid contained in the tube. Positional changes in the intensity-modulated beam profile (interference fringes) are directly related to the refractive index of the fluid in the tube. The determination of dn/n at the 10-7 level is possible in probe volumes of 350 pL. The technique has been applied to tubes as small as 75 mu m inner diameter and as large as 1.0 mm inner diameter. No modification of the simple optical bench is required for facilitating the determination of refractive index for the complete range of tube diameters.

  1. Improved Ambient Pressure Pyroelectric Ion Source

    NASA Technical Reports Server (NTRS)

    Beegle, Luther W.; Kim, Hugh I.; Kanik, Isik; Ryu, Ernest K.; Beckett, Brett

    2011-01-01

    The detection of volatile vapors of unknown species in a complex field environment is required in many different applications. Mass spectroscopic techniques require subsystems including an ionization unit and sample transport mechanism. All of these subsystems must have low mass, small volume, low power, and be rugged. A volatile molecular detector, an ambient pressure pyroelectric ion source (APPIS) that met these requirements, was recently reported by Caltech researchers to be used in in situ environments.

  2. NRL SSD Research Achievements: 19601970. Volume 1

    DTIC Science & Technology

    2015-10-30

    radio sources between declinations +10 and -20,” Mills, B.Y., Slee O.B., Hill, E.R. 1958, Australian J. Phys., 11 , 360-387 12. “SPEAR: Small Payload... 11 . SPONSOR / MONITOR’S REPORT NUMBER(S) 12. DISTRIBUTION / AVAILABILITY STATEMENT 13. SUPPLEMENTARY NOTES 14. ABSTRACT 15. SUBJECT TERMS 16...from a tour-de-force lunar occultation rocket experiment; and the First Detection of X-Ray Pulsations from the Crab Pulsar that matched the radio

  3. High-resolution magnetic resonance spectroscopy using a solid-state spin sensor

    NASA Astrophysics Data System (ADS)

    Glenn, David R.; Bucher, Dominik B.; Lee, Junghyun; Lukin, Mikhail D.; Park, Hongkun; Walsworth, Ronald L.

    2018-03-01

    Quantum systems that consist of solid-state electronic spins can be sensitive detectors of nuclear magnetic resonance (NMR) signals, particularly from very small samples. For example, nitrogen–vacancy centres in diamond have been used to record NMR signals from nanometre-scale samples, with sensitivity sufficient to detect the magnetic field produced by a single protein. However, the best reported spectral resolution for NMR of molecules using nitrogen–vacancy centres is about 100 hertz. This is insufficient to resolve the key spectral identifiers of molecular structure that are critical to NMR applications in chemistry, structural biology and materials research, such as scalar couplings (which require a resolution of less than ten hertz) and small chemical shifts (which require a resolution of around one part per million of the nuclear Larmor frequency). Conventional, inductively detected NMR can provide the necessary high spectral resolution, but its limited sensitivity typically requires millimetre-scale samples, precluding applications that involve smaller samples, such as picolitre-volume chemical analysis or correlated optical and NMR microscopy. Here we demonstrate a measurement technique that uses a solid-state spin sensor (a magnetometer) consisting of an ensemble of nitrogen–vacancy centres in combination with a narrowband synchronized readout protocol to obtain NMR spectral resolution of about one hertz. We use this technique to observe NMR scalar couplings in a micrometre-scale sample volume of approximately ten picolitres. We also use the ensemble of nitrogen–vacancy centres to apply NMR to thermally polarized nuclear spins and resolve chemical-shift spectra from small molecules. Our technique enables analytical NMR spectroscopy at the scale of single cells.

  4. Ring-oven based preconcentration technique for microanalysis: simultaneous determination of Na, Fe, and Cu in fuel ethanol by laser induced breakdown spectroscopy.

    PubMed

    Cortez, Juliana; Pasquini, Celio

    2013-02-05

    The ring-oven technique, originally applied for classical qualitative analysis in the years 1950s to 1970s, is revisited to be used in a simple though highly efficient and green procedure for analyte preconcentration prior to its determination by the microanalytical techniques presently available. The proposed preconcentration technique is based on the dropwise delivery of a small volume of sample to a filter paper substrate, assisted by a flow-injection-like system. The filter paper is maintained in a small circular heated oven (the ring oven). Drops of the sample solution diffuse by capillarity from the center to a circular area of the paper substrate. After the total sample volume has been delivered, a ring with a sharp (c.a. 350 μm) circular contour, of about 2.0 cm diameter, is formed on the paper to contain most of the analytes originally present in the sample volume. Preconcentration coefficients of the analyte can reach 250-fold (on a m/m basis) for a sample volume as small as 600 μL. The proposed system and procedure have been evaluated to concentrate Na, Fe, and Cu in fuel ethanol, followed by simultaneous direct determination of these species in the ring contour, employing the microanalytical technique of laser induced breakdown spectroscopy (LIBS). Detection limits of 0.7, 0.4, and 0.3 μg mL(-1) and mean recoveries of (109 ± 13)%, (92 ± 18)%, and (98 ± 12)%, for Na, Fe, and Cu, respectively, were obtained in fuel ethanol. It is possible to anticipate the application of the technique, coupled to modern microanalytical and multianalyte techniques, to several analytical problems requiring analyte preconcentration and/or sample stabilization.

  5. Treatment of early non-small cell lung cancer, stage IA, by image-guided robotic stereotactic radioablation--CyberKnife.

    PubMed

    Brown, William T; Wu, Xiaodong; Amendola, Beatriz; Perman, Mark; Han, Hoke; Fayad, Fahed; Garcia, Silvio; Lewin, Alan; Abitbol, Andre; de la Zerda, Alberto; Schwade, James G

    2007-01-01

    To evaluate the efficacy of using image-guided robotic stereotactic radioablation as an alternative treatment modality for patients with surgically resectable, but medically inoperable, T1 N0 M0, stage IA non-small cell lung cancer. Between January 2004 and May 2006, 19 patients, 11 women and 8 men ranging in age from 52 to 88 years, with stage IA non-small cell lung cancer were treated. Tumor volume ranged from 1.7 to 13 mL. Total doses ranged from 24 to 60 Gy delivered in 3 fractions. Eleven patients received 60 Gy. Real-time target localization was accomplished by radiographic detection of fiducial marker(s) implanted within the tumor combined with respiratory motion tracking. All patients tolerated radioablation well with fatigue as the main side effect. Fourteen patients are alive from 1 to 25 months posttreatment. Four patients died: 2 of comorbid disease and 2 of cancer progression (status post 60 and 55.5 Gy). Three patients developed grade I radiation pneumonitis. Two patients have stable disease. In 3 patients, cancer recurred in the planning treatment volume: in 2 patients after treatment with 60 Gy and in 1 patient after treatment with 55.5 Gy. One patient had local control in the target volume but developed metastasis to the ipsilateral hilum. Nine patients had a complete response and show no evidence of disease. In our early experience, stereotactic radioablation using the CyberKnife system appears to be a safe, minimally invasive, and effective modality for treating early stage lung cancer in patients with medically inoperable disease. Dose escalation and/or increasing the treatment volumes, with the aid of the high conformality of this technique, may help to achieve further improvements in these promising results.

  6. Hypervelocity Impact (HVI). Volume 8; Tile Small Targets A-1, Ag-1, B-1, and Bg-1

    NASA Technical Reports Server (NTRS)

    Gorman, Michael R.; Ziola, Steven M.

    2007-01-01

    During 2003 and 2004, the Johnson Space Center's White Sands Testing Facility in Las Cruces, New Mexico conducted hypervelocity impact tests on the space shuttle wing leading edge. Hypervelocity impact tests were conducted to determine if Micro-Meteoroid/Orbital Debris impacts could be reliably detected and located using simple passive ultrasonic methods. The objective of Targets A-1, Ag-1, B-1, and Bg-1 was to study hypervelocity impacts on the reinforced Shuttle Heat Shield Tiles of the Wing. Impact damage was detected using lightweight, low power instrumentation capable of being used in flight.

  7. Hypervelocity Impact (HVI). Volume 2; WLE Small-Scale Fiberglass Panel Flat Multi-Layer Targets A-1, A-2, and B-1

    NASA Technical Reports Server (NTRS)

    Gorman, Michael R.; Ziola, Steven M.

    2007-01-01

    During 2003 and 2004, the Johnson Space Center's White Sands Testing Facility in Las Cruces, New Mexico conducted hypervelocity impact tests on the space shuttle wing leading edge. Hypervelocity impact tests were conducted to determine if Micro-Meteoroid/Orbital Debris impacts could be reliably detected and located using simple passive ultrasonic methods. The objective of Targets A-1, A-2, and B-2 was to study hypervelocity impacts through multi-layered panels simulating Whipple shields on spacecraft. Impact damage was detected using lightweight, low power instrumentation capable of being used in flight.

  8. Hypervelocity Impact (HVI). Volume 4; WLE Small-Scale Fiberglass Panel Flat Target C-2

    NASA Technical Reports Server (NTRS)

    Gorman, Michael R.; Ziola, Steven M.

    2007-01-01

    During 2003 and 2004, the Johnson Space Center's White Sands Testing Facility in Las Cruces, New Mexico conducted hypervelocity impact tests on the space shuttle wing leading edge. Hypervelocity impact tests were conducted to determine if Micro-Meteoroid/Orbital Debris impacts could be reliably detected and located using simple passive ultrasonic methods. The objective of Target C-2 was to study impacts through the reinforced carboncarbon (RCC) panels of the Wing Leading Edge. Fiberglass was used in place of RCC in the initial tests. Impact damage was detected using lightweight, low power instrumentation capable of being used in flight.

  9. Hypervelocity Impact (HVI). Volume 3; WLE Small-Scale Fiberglass Panel Flat Target C-1

    NASA Technical Reports Server (NTRS)

    Gorman, Michael R.; Ziola, Steven M.

    2007-01-01

    During 2003 and 2004, the Johnson Space Center's White Sands Testing Facility in Las Cruces, New Mexico conducted hypervelocity impact tests on the space shuttle wing leading edge. Hypervelocity impact tests were conducted to determine if Micro-Meteoroid/Orbital Debris impacts could be reliably detected and located using simple passive ultrasonic methods. The objective of Target C-1 was to study hypervelocity impacts on the reinforced carbon-carbon (RCC) panels of the Wing Leading Edge. Fiberglass was used in place of RCC in the initial tests. Impact damage was detected using lightweight, low power instrumentation capable of being used in flight.

  10. Detection of flat colorectal polyps at screening CT colonography in comparison with conventional polypoid lesions.

    PubMed

    Sakamoto, Takashi; Mitsuzaki, Katsuhiko; Utsunomiya, Daisuke; Matsuda, Katsuhiko; Yamamura, Sadahiro; Urata, Joji; Kawakami, Megumi; Yamashita, Yasuyuki

    2012-09-01

    Although the screening of small, flat polyps is clinically important, the role of CT colonography (CTC) screening in their detection has not been thoroughly investigated. To evaluate the detection capability and usefulness of CTC in the screening of flat and polypoid lesions by comparing CTC with optic colonoscopy findings as the gold standard. We evaluated the CTC detection capability for flat colorectal polyps with a flat surface and a height not exceeding 3 mm (n = 42) by comparing to conventional polypoid lesions (n = 418) according to the polyp diameter. Four types of reconstruction images including multiplanar reconstruction, volume rendering, virtual gross pathology, and virtual endoscopic images were used for visual analysis. We compared the abilities of the four reconstructions for polyp visualization. Detection sensitivity for flat polyps was 31.3%, 44.4%, and 87.5% for lesions measuring 2-3 mm, 4-5 mm, and ≥6 mm, respectively; the corresponding sensitivity for polypoid lesions was 47.6%, 79.0%, and 91.7%. The overall sensitivity for flat lesions (47.6%) was significantly lower than polypoid lesions (64.1%). Virtual endoscopic imaging showed best visualization among the four reconstructions. Colon cancers were detected in eight patients by optic colonoscopy, and CTC detected colon cancers in all eight patients. CTC using 64-row multidetector CT is useful for colon cancer screening to detect colorectal polyps while the detection of small, flat lesions is still challenging.

  11. Solid-contact potentiometric polymer membrane microelectrodes for the detection of silver ions at the femtomole level

    PubMed Central

    Rubinova, Nastassia; Chumbimuni-Torres, Karin; Bakker, Eric

    2010-01-01

    In recent years, ion-selective electrodes based on polymer membranes have been shown to exhibit detection limits that are often in the nanomolar concentration range, and thus drastically lower than traditionally accepted. Since potentiometry is less dependent on scaling laws that other established analytical techniques, their performance in confined sample volumes is explored here. Solid-contact silver-selective microelectrodes, with a sodium-selective microelectrode as a reference, were inserted into a micropipette tip used as a 50-μl sample. The observed potential stabilities, reproducibilities and detection limits were attractive and largely matched that for large 100-ml samples. This should pave the way for further experiments to detecting ultra-small total ion concentrations by potentiometry, especially when used as a transducer after an amplification step in bioanalysis. PMID:20543910

  12. Determination of dioxin-like polychlorinated biphenyls in 1 mL whole blood using programmable temperature vaporization large volume injection coupled to gas chromatogram and high-resolution mass spectrometry.

    PubMed

    Shen, Haitao; Guan, Rongfa; Li, Jingguang; Zhang, Lei; Ren, Yiping; Xu, Xiaomin; Song, Yang; Zhao, Yunfeng; Han, Jianlong; Wu, Yongning

    2013-03-12

    A sensitive method based on programmable temperature vaporization large volume injection coupled to gas chromatogram and high-resolution mass spectrometry (PTV-GC-HRMS) has been developed for the determination of ultra trace levels of dioxin-like polychlorinated biphenyls (DL PCBs) in small amounts of human blood. Blood samples (1mL) were first extracted by column extraction and then purified with column chromatorgraphies. Final extracts (20μL) were introduced to the PTV injector under the solvent vent mode and detected by GC-HRMS (SIM mode). PTV parameters were observed by changing one factor at a time (practical conditions: vent flow: 50mLmin(-1), vent pressure: 0kPa and vent time: 0.1min), recoveries of most PCB congeners ranged from 55.1% to 108%, and method detection limits were in the range of 0.11-1.63pgg(-1). Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Prototype of a Muon Tomography Station with GEM detectors for Detection of Shielded Nuclear Contraband

    NASA Astrophysics Data System (ADS)

    Staib, Michael; Bhopatkar, Vallary; Bittner, William; Hohlmann, Marcus; Locke, Judson; Twigger, Jessie; Gnanvo, Kondo

    2012-03-01

    Muon tomography for homeland security aims at detecting well-shielded nuclear contraband in cargo and imaging it in 3D. The technique exploits multiple scattering of atmospheric cosmic ray muons, which is stronger in dense, high-Z materials, e.g. enriched uranium, than in low-Z and medium-Z shielding materials. We have constructed and are operating a compact Muon Tomography Station (MTS) that tracks muons with eight 30 cm x 30 cm Triple Gas Electron Multiplier (GEM) detectors placed on the sides of a cubic-foot imaging volume. A point-of-closest-approach algorithm applied to reconstructed incident and exiting tracks is used to create a tomographic reconstruction of the material within the active volume. We discuss the performance of this MTS prototype including characterization and commissioning of the GEM detectors and the data acquisition systems. We also present experimental tomographic images of small high-Z objects including depleted uranium with and without shielding and discuss the performance of material discrimination using this method.

  14. Highly efficient circulating tumor cell isolation from whole blood and label-free enumeration using polymer-based microfluidics with an integrated conductivity sensor.

    PubMed

    Adams, André A; Okagbare, Paul I; Feng, Juan; Hupert, Matuesz L; Patterson, Don; Göttert, Jost; McCarley, Robin L; Nikitopoulos, Dimitris; Murphy, Michael C; Soper, Steven A

    2008-07-09

    A novel microfluidic device that can selectively and specifically isolate exceedingly small numbers of circulating tumor cells (CTCs) through a monoclonal antibody (mAB) mediated process by sampling large input volumes (>/=1 mL) of whole blood directly in short time periods (<37 min) was demonstrated. The CTCs were concentrated into small volumes (190 nL), and the number of cells captured was read without labeling using an integrated conductivity sensor following release from the capture surface. The microfluidic device contained a series (51) of high-aspect ratio microchannels (35 mum width x 150 mum depth) that were replicated in poly(methyl methacrylate), PMMA, from a metal mold master. The microchannel walls were covalently decorated with mABs directed against breast cancer cells overexpressing the epithelial cell adhesion molecule (EpCAM). This microfluidic device could accept inputs of whole blood, and its CTC capture efficiency was made highly quantitative (>97%) by designing capture channels with the appropriate widths and heights. The isolated CTCs were readily released from the mAB capturing surface using trypsin. The released CTCs were then enumerated on-device using a novel, label-free solution conductivity route capable of detecting single tumor cells traveling through the detection electrodes. The conductivity readout provided near 100% detection efficiency and exquisite specificity for CTCs due to scaling factors and the nonoptimal electrical properties of potential interferences (erythrocytes or leukocytes). The simplicity in manufacturing the device and its ease of operation make it attractive for clinical applications requiring one-time use operation.

  15. Highly Efficient Circulating Tumor Cell Isolation from Whole Blood and Label-Free Enumeration Using Polymer-Based Microfluidics with an Integrated Conductivity Sensor

    PubMed Central

    Adams, André A.; Okagbare, Paul I.; Feng, Juan; Hupert, Matuesz L.; Patterson, Don; Göttert, Jost; McCarley, Robin L.; Nikitopoulos, Dimitris; Murphy, Michael C.; Soper, Steven A.

    2008-01-01

    A novel microfluidic device that can selectively and specifically isolate exceedingly small numbers of circulating tumor cells (CTCs) through a monoclonal antibody (mAB) mediated process by sampling large input volumes (≥1 mL) of whole blood directly in short time periods (<37 min) was demonstrated. The CTCs were concentrated into small volumes (190 nL), and the number of cells captured was read without labeling using an integrated conductivity sensor following release from the capture surface. The microfluidic device contained a series (51) of high-aspect ratio microchannels (35 μm width × 150 μm depth) that were replicated in poly(methyl methacrylate), PMMA, from a metal mold master. The microchannel walls were covalently decorated with mABs directed against breast cancer cells overexpressing the epithelial cell adhesion molecule (EpCAM). This microfluidic device could accept inputs of whole blood, and its CTC capture efficiency was made highly quantitative (>97%) by designing capture channels with the appropriate widths and heights. The isolated CTCs were readily released from the mAB capturing surface using trypsin. The released CTCs were then enumerated on-device using a novel, label-free solution conductivity route capable of detecting single tumor cells traveling through the detection electrodes. The conductivity readout provided near 100% detection efficiency and exquisite specificity for CTCs due to scaling factors and the nonoptimal electrical properties of potential interferences (erythrocytes or leukocytes). The simplicity in manufacturing the device and its ease of operation make it attractive for clinical applications requiring one-time use operation. PMID:18557614

  16. ELISA-type assays of trace biomarkers using microfluidic methods.

    PubMed

    Dong, Jinhua; Ueda, Hiroshi

    2017-09-01

    Recently, great progress has been achieved for analytical technologies for biological substances. Traditionally, detection methods for analytes mainly rely on large instrumental analyses. These methods require costly equipment, skilled operators and long measurement time despite their generally low sensitivity. In contrast, immunoassays are becoming more and more popular for it is powerful, inexpensive, and convenient nature. Immunoassay has a range of applications, because it employs antibody, a protein produced by plasma cells in the acquired immune system to identify and neutralize diverse pathogens and other exogenous substances. However, the sensitivity of conventional immunoassays so far is limited by their reaction principles and detection methods. The microfluidics technology is the one that manipulates small volumes of fluid and flow, which has the potential to miniaturize many laboratory procedures. Immunoassays on microfluidic devices have been studied extensively and have gained significant attention owing to intrinsic advantages offered by the assay platforms. The techniques have allowed the miniaturization of conventional immunoassay and bring the advantages such as small volumes of samples and reagents as well as the decrease of contamination, which results in the decline of false-positive results. Ultimately, the combination of immunoassays with microfluidics affords a promising platform for multiple, sensitive, and automatic point-of-care diagnostics. Recent achievements on microfluidic devices and immunoassay detection systems including digital assay employing single molecule will be introduced in detail and the strategies for faster and more sensitive configurations in microfluidic immunosensors will be highlighted. WIREs Nanomed Nanobiotechnol 2017, 9:e1457. doi: 10.1002/wnan.1457 For further resources related to this article, please visit the WIREs website. © 2017 Wiley Periodicals, Inc.

  17. Nanoparticle functionalised small-core suspended-core fibre - a novel platform for efficient sensing.

    PubMed

    Doherty, Brenda; Csáki, Andrea; Thiele, Matthias; Zeisberger, Matthias; Schwuchow, Anka; Kobelke, Jens; Fritzsche, Wolfgang; Schmidt, Markus A

    2017-02-01

    Detecting small quantities of specific target molecules is of major importance within bioanalytics for efficient disease diagnostics. One promising sensing approach relies on combining plasmonically-active waveguides with microfluidics yielding an easy-to-use sensing platform. Here we introduce suspended-core fibres containing immobilised plasmonic nanoparticles surrounding the guiding core as a concept for an entirely integrated optofluidic platform for efficient refractive index sensing. Due to the extremely small optical core and the large adjacent microfluidic channels, over two orders of magnitude of nanoparticle coverage densities have been accessed with millimetre-long sample lengths showing refractive index sensitivities of 170 nm/RIU for aqueous analytes where the fibre interior is functionalised by gold nanospheres. Our concept represents a fully integrated optofluidic sensing system demanding small sample volumes and allowing for real-time analyte monitoring, both of which are highly relevant within invasive bioanalytics, particularly within molecular disease diagnostics and environmental science.

  18. Effect of sample volume on metastable zone width and induction time

    NASA Astrophysics Data System (ADS)

    Kubota, Noriaki

    2012-04-01

    The metastable zone width (MSZW) and the induction time, measured for a large sample (say>0.1 L) are reproducible and deterministic, while, for a small sample (say<1 mL), these values are irreproducible and stochastic. Such behaviors of MSZW and induction time were theoretically discussed both with stochastic and deterministic models. Equations for the distribution of stochastic MSZW and induction time were derived. The average values of stochastic MSZW and induction time both decreased with an increase in sample volume, while, the deterministic MSZW and induction time remained unchanged. Such different behaviors with variation in sample volume were explained in terms of detection sensitivity of crystallization events. The average values of MSZW and induction time in the stochastic model were compared with the deterministic MSZW and induction time, respectively. Literature data reported for paracetamol aqueous solution were explained theoretically with the presented models.

  19. Detection of Botulinum Neurotoxin Serotype A, B, and F Proteolytic Activity in Complex Matrices with Picomolar to Femtomolar Sensitivity

    PubMed Central

    Dunning, F. Mark; Ruge, Daniel R.; Piazza, Timothy M.; Stanker, Larry H.; Zeytin, Füsûn N.

    2012-01-01

    Rapid, high-throughput assays that detect and quantify botulinum neurotoxin (BoNT) activity in diverse matrices are required for environmental, clinical, pharmaceutical, and food testing. The current standard, the mouse bioassay, is sensitive but is low in throughput and precision. In this study, we present three biochemical assays for the detection and quantification of BoNT serotype A, B, and F proteolytic activities in complex matrices that offer picomolar to femtomolar sensitivity with small assay volumes and total assay times of less than 24 h. These assays consist of magnetic beads conjugated with BoNT serotype-specific antibodies that are used to purify BoNT from complex matrices before the quantification of bound BoNT proteolytic activity using the previously described BoTest reporter substrates. The matrices tested include human serum, whole milk, carrot juice, and baby food, as well as buffers containing common pharmaceutical excipients. The limits of detection were below 1 pM for BoNT/A and BoNT/F and below 10 pM for BoNT/B in most tested matrices using 200-μl samples and as low as 10 fM for BoNT/A with an increased sample volume. Together, these data describe rapid, robust, and high-throughput assays for BoNT detection that are compatible with a wide range of matrices. PMID:22923410

  20. A Model of Thermal Conductivity for Planetary Soils. 2; Theory for Cemented Soils

    NASA Technical Reports Server (NTRS)

    Piqueux, S.; Christensen, P. R.

    2009-01-01

    A numerical model of heat conduction through particulate media made of spherical grains cemented by various bonding agents is presented. The pore-filling gas conductivity, volume fraction, and thermal conductivity of the cementing phase are tunable parameters. Cement fractions <0.001-0.01% in volume have small effects on the soil bulk thermal conductivity. A significant conductivity increase (factor 3-8) is observed for bond fractions of 0.01 to 1% in volume. In the 1 to 15% bond fraction domain, the conductivity increases continuously but less intensely (25-100% conductivity increase compared to a 1% bond system). Beyond 15% of cements, the conductivity increases vigorously and the bulk conductivity rapidly approaches that of bedrock. The composition of the cements (i.e. conductivity) has little influence on the bulk thermal inertia of the soil, especially if the volume of bond <10%. These results indicate that temperature measurements are sufficient to detect cemented soils and quantify the amount of cementing phase, but the mineralogical nature of the bonds and the typical grain size are unlikely to be determined from orbit. On Mars, a widespread surface unit characterized by a medium albedo (0.19-0.26) and medium/high thermal inertia (200-600 J s(0.5)/sq m/K) has long been hypothesized to be associated with a duricrust. The fraction of cement required to fit the thermal data is less than approx.1-5% by volume. This small amount of material is consistent with orbital observations, confirming that soil cementation is an important factor controlling the thermal inertia of the Martian surface

  1. A model of thermal conductivity for planetary soils: 2. Theory for cemented soils

    NASA Astrophysics Data System (ADS)

    Piqueux, S.; Christensen, P. R.

    2009-09-01

    A numerical model of heat conduction through particulate media made of spherical grains cemented by various bonding agents is presented. The pore-filling gas conductivity, volume fraction, and thermal conductivity of the cementing phase are tunable parameters. Cement fractions <0.001-0.01% in volume have small effects on the soil bulk thermal conductivity. A significant conductivity increase (factor 3-8) is observed for bond fractions of 0.01 to 1% in volume. In the 1 to 15% bond fraction domain, the conductivity increases continuously but less intensely (25-100% conductivity increase compared to a 1% bond system). Beyond 15% of cements, the conductivity increases vigorously and the bulk conductivity rapidly approaches that of bedrock. The composition of the cements (i.e. conductivity) has little influence on the bulk thermal inertia of the soil, especially if the volume of bond <10%. These results indicate that temperature measurements are sufficient to detect cemented soils and quantify the amount of cementing phase, but the mineralogical nature of the bonds and the typical grain size are unlikely to be determined from orbit. On Mars, a widespread surface unit characterized by a medium albedo (0.19-0.26) and medium/high thermal inertia (200-600 J s-0.5 m-2 K-1) has long been hypothesized to be associated with a duricrust. The fraction of cement required to fit the thermal data is less than ˜1-5% by volume. This small amount of material is consistent with orbital observations, confirming that soil cementation is an important factor controlling the thermal inertia of the Martian surface.

  2. Prediction of Packed Cell Volume after Whole Blood Transfusion in Small Ruminants and South American Camelids: 80 Cases (2006-2016).

    PubMed

    Luethy, D; Stefanovski, D; Salber, R; Sweeney, R W

    2017-11-01

    Calculation of desired whole blood transfusion volume relies on an estimate of an animal's circulating blood volume, generally accepted to be 0.08 L/kg or 8% of the animal's body weight in kilograms. To use packed cell volume before and after whole blood transfusion to evaluate the accuracy of a commonly used equation to predict packed cell volume after transfusion in small ruminants and South American camelids; to determine the nature and frequency of adverse transfusion reactions in small ruminants and camelids after whole blood transfusion. Fifty-eight small ruminants and 22 alpacas that received whole blood transfusions for anemia. Retrospective case series; medical record review for small ruminants and camelids that received whole blood transfusions during hospitalization. Mean volume of distribution of blood as a fraction of body weight in sheep (0.075 L/kg, 7.5% BW) and goats (0.076 L/kg, 7.6% BW) differed significantly (P < 0.01) from alpacas (0.103 L/kg, 10.3% BW). Mild transfusion reactions were noted in 16% of transfusions. The generally accepted value of 8% for circulating blood volume (volume of distribution of blood) is adequate for calculation of transfusion volumes; however, use of the species-specific circulating blood volume can improve calculation of transfusion volume to predict and achieve desired packed cell volume. The incidence of transfusion reactions in small ruminants and camelids is low. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  3. Computer-aided pulmonary image analysis in small animal models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, Ziyue; Mansoor, Awais; Mollura, Daniel J.

    Purpose: To develop an automated pulmonary image analysis framework for infectious lung diseases in small animal models. Methods: The authors describe a novel pathological lung and airway segmentation method for small animals. The proposed framework includes identification of abnormal imaging patterns pertaining to infectious lung diseases. First, the authors’ system estimates an expected lung volume by utilizing a regression function between total lung capacity and approximated rib cage volume. A significant difference between the expected lung volume and the initial lung segmentation indicates the presence of severe pathology, and invokes a machine learning based abnormal imaging pattern detection system next.more » The final stage of the proposed framework is the automatic extraction of airway tree for which new affinity relationships within the fuzzy connectedness image segmentation framework are proposed by combining Hessian and gray-scale morphological reconstruction filters. Results: 133 CT scans were collected from four different studies encompassing a wide spectrum of pulmonary abnormalities pertaining to two commonly used small animal models (ferret and rabbit). Sensitivity and specificity were greater than 90% for pathological lung segmentation (average dice similarity coefficient > 0.9). While qualitative visual assessments of airway tree extraction were performed by the participating expert radiologists, for quantitative evaluation the authors validated the proposed airway extraction method by using publicly available EXACT’09 data set. Conclusions: The authors developed a comprehensive computer-aided pulmonary image analysis framework for preclinical research applications. The proposed framework consists of automatic pathological lung segmentation and accurate airway tree extraction. The framework has high sensitivity and specificity; therefore, it can contribute advances in preclinical research in pulmonary diseases.« less

  4. Quantum Dot-Fullerene Based Molecular Beacon Nanosensors for Rapid, Highly Sensitive Nucleic Acid Detection.

    PubMed

    Liu, Ye; Kannegulla, Akash; Wu, Bo; Cheng, Li-Jing

    2018-05-15

    Spherical fullerene (C 60 ) can quench the fluorescence of a quantum dot (QD) through energy transfer and charge transfer processes, with the quenching efficiency regulated by the number of proximate C 60 on each QD. With the quenching property and its small size compared with other nanoparticle-based quenchers, it is advantageous to group a QD reporter and multiple C 60 -labeled oligonucleotide probes to construct a molecular beacon (MB) probe for sensitive, robust nucleic acid detection. We demonstrated a rapid, high-sensitivity DNA detection method using the nanosensors composed of QD-C 60 based MBs carried by magnetic nanoparticles (MNPs). The assay was accelerated by first dispersing the nanosensors in analytes for highly efficient DNA capture resulting from short-distance 3-dimensional diffusion of targets to the sensor surface and then concentrating the nanosensors to a substrate by magnetic force to amplify the fluorescence signal for target quantification. The enhanced mass transport enabled a rapid detection (< 10 min) with a small sample volume (1-10 µl). The high signal-to-noise ratio produced by the QD-C 60 pairs and magnetic concentration yielded a detection limit of 100 fM (~106 target DNA copies for a 10 µl analyte). The rapid, sensitive, label-free detection method will benefit the applications in point-of-care molecular diagnostic technologies.

  5. Real-Time Optical Surveillance of LEO/MEO with Small Telescopes

    NASA Astrophysics Data System (ADS)

    Zimmer, P.; McGraw, J.; Ackermann, M.

    J.T. McGraw and Associates, LLC operates two proof-of-concept wide-field imaging systems to test novel techniques for uncued surveillance of LEO/MEO/GEO and, in collaboration with the University of New Mexico (UNM), uses a third small telescope for rapidly queued same-orbit follow-up observations. Using our GPU-accelerated detection scheme, the proof-of-concept systems operating at sites near and within Albuquerque, NM, have detected objects fainter than V=13 at greater than 6 sigma significance. This detection approximately corresponds to a 16 cm object with albedo of 0.12 at 1000 km altitude. Dozens of objects are measured during each operational twilight period, many of which have no corresponding catalog object. The two proof-of-concept systems, separated by ~30km, work together by taking simultaneous images of the same orbital volume to constrain the orbits of detected objects using parallax measurements. These detections are followed-up by imaging photometric observations taken at UNM to confirm and further constrain the initial orbit determination and independently assess the objects and verify the quality of the derived orbits. This work continues to demonstrate that scalable optical systems designed for real-time detection of fast moving objects, which can be then handed off to other instruments capable of tracking and characterizing them, can provide valuable real-time surveillance data at LEO and beyond, which substantively informs the SSA process.

  6. Fishing in the Water: Effect of Sampled Water Volume on Environmental DNA-Based Detection of Macroinvertebrates.

    PubMed

    Mächler, Elvira; Deiner, Kristy; Spahn, Fabienne; Altermatt, Florian

    2016-01-05

    Accurate detection of organisms is crucial for the effective management of threatened and invasive species because false detections directly affect the implementation of management actions. The use of environmental DNA (eDNA) as a species detection tool is in a rapid development stage; however, concerns about accurate detections using eDNA have been raised. We evaluated the effect of sampled water volume (0.25 to 2 L) on the detection rate for three macroinvertebrate species. Additionally, we tested (depending on the sampled water volume) what amount of total extracted DNA should be screened to reduce uncertainty in detections. We found that all three species were detected in all volumes of water. Surprisingly, however, only one species had a positive relationship between an increased sample volume and an increase in the detection rate. We conclude that the optimal sample volume might depend on the species-habitat combination and should be tested for the system where management actions are warranted. Nevertheless, we minimally recommend sampling water volumes of 1 L and screening at least 14 μL of extracted eDNA for each sample to reduce uncertainty in detections when studying macroinvertebrates in rivers and using our molecular workflow.

  7. Multispectral Mueller polarimetric imaging detecting residual cancer and cancer regression after neoadjuvant treatment for colorectal carcinomas

    NASA Astrophysics Data System (ADS)

    Pierangelo, Angelo; Manhas, Sandeep; Benali, Abdelali; Fallet, Clément; Totobenazara, Jean-Laurent; Antonelli, Maria-Rosaria; Novikova, Tatiana; Gayet, Brice; De Martino, Antonello; Validire, Pierre

    2013-04-01

    This work is devoted to a first exploration of Mueller polarimetric imaging for the detection of residual cancer after neoadjuvant treatment for the rectum. Three samples of colorectal carcinomas treated by radiochemotherapy together with one untreated sample are analyzed ex vivo before fixation in formalin by using a multispectral Mueller polarimetric imaging system operated from 500 to 700 nm. The Mueller images, analyzed using the Lu-Chipmann decomposition, show negligible diattenuation and retardation. The nonirradiated rectum exhibits a variation of depolarization with cancer evolution stage. At all wavelengths on irradiated samples, the contrast between the footprint of the initial tumor and surrounding healthy tissue is found to be much smaller for complete tumor regression than when a residual tumor is present, even at volume fractions of the order of 5%. This high sensitivity is attributed to the modification of stromal collagen induced by the cancer. The depolarization contrast between treated cancer and healthy tissue is found to increase monotonously with the volume fraction of residual cancer in the red part of the spectrum. Polarimetric imaging is a promising technique for detecting short-time small residual cancers, which is valuable information for pathological diagnosis and patient management by clinicians.

  8. Prevalence of gastrointestinal helminths and anthelmintic resistance on small-scale farms in Gauteng Province, South Africa.

    PubMed

    Tsotetsi, Ana Mbokeleng; Njiro, Stephen; Katsande, Tendai Charles; Moyo, Gugulethu; Baloyi, Faculty; Mpofu, Jaison

    2013-03-01

    The present study was conducted to determine the prevalence and distribution of gastrointestinal helminths, to detect the presence of anthelmintic resistance in livestock from small-scale farms and to determine the level of helminthosis awareness among small-scale farmers in Gauteng Province, South Africa. Blood and faecal samples were collected from cattle (n = 314), sheep (n = 256) and goats (n = 311). Faecal egg counts and cultures were done, helminth genera identified and packed cell volume was assessed to detect anaemia. A faecal egg count reduction test was used to determine anthelmintic resistance against albendazole (7.5 mg/kg), levamisole (5 mg/kg) and ivermectin (0.2 mg/kg) on five small ruminant farms. A high prevalence of both nematodes and trematodes was observed; however, only 1 % of cattle had high nematode egg counts compared to goats (30 %) and sheep (32 %). Only 5 % of the animals were anaemic. Haemonchus and Calicophoron were the most dominant helminth genera in the studied ruminants. Anthelmintic resistance was detected against the three tested drugs on all the screened farms, except against albendazole and levamisole in sheep from Hammanskraal and Nigel, respectively. About 88 % of interviewed farmers were aware of veterinary helminthosis, 67 % treated against helminths and 83 % provided their livestock with nutritional supplements. This study showed that a high prevalence of helminthosis and anthelmintic resistance does occur in the study area, thus relevant strategic interventions are recommended.

  9. Detection of Influenza Virus with Specific Subtype by Using Localized Surface Plasmons Excited on a Flat Metal Surface

    NASA Astrophysics Data System (ADS)

    Ning, Jun; Nagata, Kotaro; Ainai, Akira; Hasegawa, Hideki; Kano, Hiroshi

    2013-08-01

    We report on a method to determine subtype of influenza viruses by using surface plasmons localized in microscopic region on a flat metal surface. In this method, refractive index variation arisen from interactions between viruses and their monoclonal antibodies is measured. The developed sensor shows stability of refractive index in the order of 10-4 against sample exchange. In our experiment, A/H1N1 viruses are distinguished from A/H3N2 viruses by using monoclonal antibodies immobilized on the metal surface. Since the measurement probe has the volume of ˜6 al, the method has potential to handle multiple subtypes in the measurement of a sample with ultra small volume.

  10. Identifying High-Risk Patients without Labeled Training Data: Anomaly Detection Methodologies to Predict Adverse Outcomes

    PubMed Central

    Syed, Zeeshan; Saeed, Mohammed; Rubinfeld, Ilan

    2010-01-01

    For many clinical conditions, only a small number of patients experience adverse outcomes. Developing risk stratification algorithms for these conditions typically requires collecting large volumes of data to capture enough positive and negative for training. This process is slow, expensive, and may not be appropriate for new phenomena. In this paper, we explore different anomaly detection approaches to identify high-risk patients as cases that lie in sparse regions of the feature space. We study three broad categories of anomaly detection methods: classification-based, nearest neighbor-based, and clustering-based techniques. When evaluated on data from the National Surgical Quality Improvement Program (NSQIP), these methods were able to successfully identify patients at an elevated risk of mortality and rare morbidities following inpatient surgical procedures. PMID:21347083

  11. Utility of a prototype liposomal contrast agent for x-ray imaging of breast cancer: a proof of concept using micro-CT in small animals

    NASA Astrophysics Data System (ADS)

    Badea, C. T.; Samei, E.; Ghaghada, K.; Saunders, R.; Yuan, H.; Qi, Y.; Hedlund, L. W.; Mukundan, S.

    2008-03-01

    Imaging tumor angiogenesis in small animals is extremely challenging due to the size of the tumor vessels. Consequently, both dedicated small animal imaging systems and specialized intravascular contrast agents are required. The goal of this study was to investigate the use of a liposomal contrast agent for high-resolution micro-CT imaging of breast tumors in small animals. A liposomal blood pool agent encapsulating iodine with a concentration of 65.5 mg/ml was used with a Duke Center for In Vivo Microscopy (CIVM) prototype micro-computed tomography (micro-CT) system to image the R3230AC mammary carcinoma implanted in rats. The animals were injected with equivalent volume doses (0.02 ml/kg) of contrast agent. Micro-CT with the liposomal blood pool contrast agent ensured a signal difference between the blood and the muscle higher than 450 HU allowing the visualization of the tumors 3D vascular architecture in exquisite detail at 100-micron resolution. The micro-CT data correlated well with the histological examination of tumor tissue. We also studied the ability to detect vascular enhancement with limited angle based reconstruction, i.e. tomosynthesis. Tumor volumes and their regional vascular percentage were estimated. This imaging approach could be used to better understand tumor angiogenesis and be the basis for evaluating anti-angiogenic therapies.

  12. Detecting single viruses and nanoparticles using whispering gallery microlasers.

    PubMed

    He, Lina; Ozdemir, Sahin Kaya; Zhu, Jiangang; Kim, Woosung; Yang, Lan

    2011-06-26

    There is a strong demand for portable systems that can detect and characterize individual pathogens and other nanoscale objects without the use of labels, for applications in human health, homeland security, environmental monitoring and diagnostics. However, most nanoscale objects of interest have low polarizabilities due to their small size and low refractive index contrast with the surrounding medium. This leads to weak light-matter interactions, and thus makes the label-free detection of single nanoparticles very difficult. Micro- and nano-photonic devices have emerged as highly sensitive platforms for such applications, because the combination of high quality factor Q and small mode volume V leads to significantly enhanced light-matter interactions. For example, whispering gallery mode microresonators have been used to detect and characterize single influenza virions and polystyrene nanoparticles with a radius of 30 nm (ref. 12) by measuring in the transmission spectrum either the resonance shift or mode splitting induced by the nanoscale objects. Increasing Q leads to a narrower resonance linewidth, which makes it possible to resolve smaller changes in the transmission spectrum, and thus leads to improved performance. Here, we report a whispering gallery mode microlaser-based real-time and label-free detection method that can detect individual 15-nm-radius polystyrene nanoparticles, 10-nm gold nanoparticles and influenza A virions in air, and 30 nm polystyrene nanoparticles in water. Our approach relies on measuring changes in the beat note that is produced when an ultra-narrow emission line from a whispering gallery mode microlaser is split into two modes by a nanoscale object, and these two modes then interfere. The ultimate detection limit is set by the laser linewidth, which can be made much narrower than the resonance linewidth of any passive resonator. This means that microlaser sensors have the potential to detect objects that are too small to be detected by passive resonator sensors.

  13. SERS detection of Biomolecules at Physiological pH via aggregation of Gold Nanorods mediated by Optical Forces and Plasmonic Heating

    NASA Astrophysics Data System (ADS)

    Fazio, Barbara; D'Andrea, Cristiano; Foti, Antonino; Messina, Elena; Irrera, Alessia; Donato, Maria Grazia; Villari, Valentina; Micali, Norberto; Maragò, Onofrio M.; Gucciardi, Pietro G.

    2016-06-01

    Strategies for in-liquid molecular detection via Surface Enhanced Raman Scattering (SERS) are currently based on chemically-driven aggregation or optical trapping of metal nanoparticles in presence of the target molecules. Such strategies allow the formation of SERS-active clusters that efficiently embed the molecule at the “hot spots” of the nanoparticles and enhance its Raman scattering by orders of magnitude. Here we report on a novel scheme that exploits the radiation pressure to locally push gold nanorods and induce their aggregation in buffered solutions of biomolecules, achieving biomolecular SERS detection at almost neutral pH. The sensor is applied to detect non-resonant amino acids and proteins, namely Phenylalanine (Phe), Bovine Serum Albumin (BSA) and Lysozyme (Lys), reaching detection limits in the μg/mL range. Being a chemical free and contactless technique, our methodology is easy to implement, fast to operate, needs small sample volumes and has potential for integration in microfluidic circuits for biomarkers detection.

  14. SERS detection of Biomolecules at Physiological pH via aggregation of Gold Nanorods mediated by Optical Forces and Plasmonic Heating

    PubMed Central

    Fazio, Barbara; D’Andrea, Cristiano; Foti, Antonino; Messina, Elena; Irrera, Alessia; Donato, Maria Grazia; Villari, Valentina; Micali, Norberto; Maragò, Onofrio M.; Gucciardi, Pietro G.

    2016-01-01

    Strategies for in-liquid molecular detection via Surface Enhanced Raman Scattering (SERS) are currently based on chemically-driven aggregation or optical trapping of metal nanoparticles in presence of the target molecules. Such strategies allow the formation of SERS-active clusters that efficiently embed the molecule at the “hot spots” of the nanoparticles and enhance its Raman scattering by orders of magnitude. Here we report on a novel scheme that exploits the radiation pressure to locally push gold nanorods and induce their aggregation in buffered solutions of biomolecules, achieving biomolecular SERS detection at almost neutral pH. The sensor is applied to detect non-resonant amino acids and proteins, namely Phenylalanine (Phe), Bovine Serum Albumin (BSA) and Lysozyme (Lys), reaching detection limits in the μg/mL range. Being a chemical free and contactless technique, our methodology is easy to implement, fast to operate, needs small sample volumes and has potential for integration in microfluidic circuits for biomarkers detection. PMID:27246267

  15. 40 CFR 1054.635 - What special provisions apply for small-volume engine and equipment manufacturers?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... special provisions in this part for small-volume engine and equipment manufacturers. (a) If you qualify... qualify under paragraph (1) or (2) of the definition of small-volume engine manufacturer or under...) Additional lead time and other provisions related to the transition to new emission standards. See § 1054.145...

  16. Automatic segmentation of tumor-laden lung volumes from the LIDC database

    NASA Astrophysics Data System (ADS)

    O'Dell, Walter G.

    2012-03-01

    The segmentation of the lung parenchyma is often a critical pre-processing step prior to application of computer-aided detection of lung nodules. Segmentation of the lung volume can dramatically decrease computation time and reduce the number of false positive detections by excluding from consideration extra-pulmonary tissue. However, while many algorithms are capable of adequately segmenting the healthy lung, none have been demonstrated to work reliably well on tumor-laden lungs. Of particular challenge is to preserve tumorous masses attached to the chest wall, mediastinum or major vessels. In this role, lung volume segmentation comprises an important computational step that can adversely affect the performance of the overall CAD algorithm. An automated lung volume segmentation algorithm has been developed with the goals to maximally exclude extra-pulmonary tissue while retaining all true nodules. The algorithm comprises a series of tasks including intensity thresholding, 2-D and 3-D morphological operations, 2-D and 3-D floodfilling, and snake-based clipping of nodules attached to the chest wall. It features the ability to (1) exclude trachea and bowels, (2) snip large attached nodules using snakes, (3) snip small attached nodules using dilation, (4) preserve large masses fully internal to lung volume, (5) account for basal aspects of the lung where in a 2-D slice the lower sections appear to be disconnected from main lung, and (6) achieve separation of the right and left hemi-lungs. The algorithm was developed and trained to on the first 100 datasets of the LIDC image database.

  17. Molecular Volumes and the Stokes-Einstein Equation

    ERIC Educational Resources Information Center

    Edward, John T.

    1970-01-01

    Examines the limitations of the Stokes-Einstein equation as it applies to small solute molecules. Discusses molecular volume determinations by atomic increments, molecular models, molar volumes of solids and liquids, and molal volumes. Presents an empirical correction factor for the equation which applies to molecular radii as small as 2 angstrom…

  18. Mid-IR spectroscopic instrumentation for point-of-care diagnosis using a hollow silica waveguide gas cell

    NASA Astrophysics Data System (ADS)

    Francis, Daniel; Hodgkinson, Jane; Walton, Christopher; Sizer, Jeremy; Black, Paul; Livingstone, Beth; Fowler, Dawn P.; Patel, Mitesh K.; Tatam, Ralph P.

    2017-02-01

    Laser spectroscopy provides the basis of instrumentation developed for the diagnosis of infectious disease, via quantification of organic biomarkers that are produced by associated bacteria. The technology is centred on a multichannel pulsed quantum cascade laser system that allows multiple lasers with different wavelengths to be used simultaneously, each selected to monitor a different diagnostic biomarker. The instrument also utilizes a hollow silica waveguide (HSW) gas cell which has a very high ratio of interaction pathlength to internal volume. This allows sensitive detection of low volume gas species from small volume biological samples. The spectroscopic performance of a range of HSW gas cells with different lengths and bore diameters has been assessed using methane as a test gas and a best-case limit of detection of 0.26 ppm was determined. The response time of this cell was measured as a 1,000 sccm flow of methane passed through it and was found to be 0.75 s. These results are compared with those obtained using a multi-pass Herriot cell. A prototype instrument has been built and approved for clinical trials for detection of lung infection in acute-care patients via analysis of ventilator breath. Demonstration of the instrument for headspace gas analysis is made by monitoring the methane emission from bovine faeces. The manufacture of a hospital-ready device for monitoring biomarkers of infection in the exhaled breath of intensive care ventilator patients is also presented.

  19. Long-term ground penetrating radar monitoring of a small volume DNAPL release in a natural groundwater flow field.

    PubMed

    Hwang, Yong Keun; Endres, Anthony L; Piggott, Scott D; Parker, Beth L

    2008-04-04

    An earlier field experiment at Canadian Forces Base Borden by Brewster and Annan [Geophysics 59 (1994) 1211] clearly demonstrated the capability of ground penetrating radar (GPR) reflection profiling to detect and monitor the formation of DNAPL layers in the subsurface. Their experiment involved a large volume release (770 L) of tetrachloroethylene into a portion of the sand aquifer that was hydraulically isolated from groundwater flow by sheet pile walls. In this study, we evaluated the ability of GPR profiling to detect and monitor much smaller volume releases (50 L). No subsurface confining structure was used in this experiment; hence, the DNAPL impacted zone was subjected to the natural groundwater flow regime. This condition allowed us to geophysically monitor the DNAPL mass loss over a 66 month period. Reflectivity variations on the GPR profiles were used to infer the presence and evolution of the solvent layers. GPR imaging found significant reflectivity increases due to solvent layer formation during the two week period immediately after the release. These results demonstrated the capacity of GPR profiling for the detection and monitoring of lesser volume DNAPL releases that are more representative of small-scale industrial spills. The GPR imaged solvent layers subsequently reduced in both areal extent and reflectivity after 29 months and almost completely disappeared by the end of the 66 month monitoring period. Total DNAPL mass estimates based on GPR profiling data indicated that the solvent mass was reduced to 34%-36% of its maximum value after 29 months; only 4%-9% of the solvent mass remained in the study area after 66 months. These results are consistent with independent hydrogeological estimates of remaining DNAPL mass based on the downgradient monitoring of the dissolved solvent phase. Hence, we have concluded that the long-term GPR reflectivity changes of the DNAPL layers are likely the result from the dissolution of chlorinated solvents residing in those layers. The long-term monitoring results demonstrated that GPR profiling is a promising non-invasive method for use at DNAPL contaminated sites in sandy aquifers where temporal information about immiscible contaminant mass depletion due to either natural flow or remediation is needed. However, our results also indicated that the GPR signature of older DNAPL impacted zones may not differ greatly from the uncontaminated background if significant mass reduction due to dissolution has occurred.

  20. Salt-induced aggregation and fusion of dioctadecyldimethylammonium chloride and sodium dihexadecylphosphate vesicles.

    PubMed Central

    Carmona-Ribeiro, A M; Chaimovich, H

    1986-01-01

    Small dioctadecyldimethylammonium chloride (DODAC) vesicles prepared by sonication fuse upon addition of NaCl as detected by several methods (electron microscopy, trapped volume determinations, temperature-dependent phase transition curves, and osmometer behavior. In contrast, small sodium dihexadecyl phosphate (DHP) vesicles mainly aggregate upon NaCl addition as shown by electron microscopy and the lack of osmometer behavior. Scatter-derived absorbance changes of small and large DODAC or DHP vesicles as a function of time after salt addition were obtained for a range of NaCl or amphiphile concentration. These changes were interpreted in accordance with a phenomenological model based upon fundamental light-scattering laws and simple geometrical considerations. Short-range hydration repulsion between DODAC (or DHP) vesicles is possibly the main energy barrier for the fusion process. Images FIGURE 2 FIGURE 9 PMID:3779002

  1. PCR-Based Method for Detecting Viral Penetration of Medical Exam Gloves

    PubMed Central

    Broyles, John M.; O'Connell, Kevin P.; Korniewicz, Denise M.

    2002-01-01

    The test approved by the U.S. Food and Drug Administration for assessment of the barrier quality of medical exam gloves includes visual inspection and a water leak test. Neither method tests directly the ability of gloves to prevent penetration by microorganisms. Methods that use microorganisms (viruses and bacteria) to test gloves have been developed but require classical culturing of the organism to detect it. We have developed a PCR assay for bacteriophage φX174 that allows the rapid detection of penetration of gloves by this virus. The method is suitable for use with both latex and synthetic gloves. The presence of glove powder on either latex or synthetic gloves had no effect on the ability of the PCR assay to detect bacteriophage DNA. The assay is rapid, sensitive, and inexpensive; requires only small sample volumes; and can be automated. PMID:12149320

  2. In Situ Hot-Spot Assembly as a General Strategy for Probing Single Biomolecules.

    PubMed

    Liu, Huiqiao; Li, Qiang; Li, Mingmin; Ma, Sisi; Liu, Dingbin

    2017-05-02

    Single-molecule detection using surface-enhanced Raman spectroscopy (SERS) has attracted increasing attention in chemical and biomedical analysis. However, it remains a major challenge to probe single biomolecules by means of SERS hot spots owing to the small volume of hot spots and their random distribution on substrates. We here report an in situ hot-spot assembly method as a general strategy for probing single biomolecules. As a proof-of-concept, this proposed strategy was successfully used for the detection of single microRNA-21 (miRNA-21, a potential cancer biomarker) at the single-cell level, showing great capability in differentiating the expression of miRNA-21 in single cancer cells from normal cells. This approach was further extended to single-protein detection. The versatility of the strategy opens an exciting avenue for single-molecule detection of biomarkers of interest and thus holds great promise in a variety of biological and biomedical applications.

  3. Use of dye to distinguish salt and protein crystals under microcrystallization conditions

    NASA Technical Reports Server (NTRS)

    Cosenza, Larry (Inventor); Gester, Thomas E. (Inventor); Bray, Terry L. (Inventor); DeLucas, Lawrence J. (Inventor); Hamrick, David T. (Inventor)

    2007-01-01

    An improved method of screening crystal growth conditions is provided wherein molecules are crystallized from solutions containing dyes. These dyes are selectively incorporated or associated with crystals of particular character thereby rendering crystals of particular character colored and improving detection of the dyed crystals. A preferred method involves use of dyes in protein solutions overlayed by oil. Use of oil allows the use of small volumes of solution and facilitates the screening of large numbers of crystallization conditions in arrays using automated devices that dispense appropriate solutions to generate crystallization trials, overlay crystallization trials with an oil, provide appropriate conditions conducive to crystallization and enhance detection of dyed (colored) or undyed (uncolored) crystals that result.

  4. A Miniaturized QEPAS Trace Gas Sensor with a 3D-Printed Acoustic Detection Module.

    PubMed

    Yang, Xiaotao; Xiao, Youhong; Ma, Yufei; He, Ying; Tittel, Frank K

    2017-07-31

    A 3D printing technique was introduced to a quartz-enhanced photoacoustic spectroscopy (QEPAS) sensor and is reported for the first time. The acoustic detection module (ADM) was designed and fabricated using the 3D printing technique and the ADM volume was compressed significantly. Furthermore, a small grin lens was used for laser focusing and facilitated the beam adjustment in the 3D-printed ADM. A quartz tuning fork (QTF) with a low resonance frequency of 30.72 kHz was used as the acoustic wave transducer and acetylene (C₂H₂) was chosen as the analyte. The reported miniaturized QEPAS trace gas sensor is useful in actual sensor applications.

  5. Drop-on-demand sample introduction system coupled with the flowing atmospheric-pressure afterglow for direct molecular analysis of complex liquid microvolume samples.

    PubMed

    Schaper, J Niklas; Pfeuffer, Kevin P; Shelley, Jacob T; Bings, Nicolas H; Hieftje, Gary M

    2012-11-06

    One of the fastest developing fields in analytical spectrochemistry in recent years is ambient desorption/ionization mass spectrometry (ADI-MS). This burgeoning interest has been due to the demonstrated advantages of the method: simple mass spectra, little or no sample preparation, and applicability to samples in the solid, liquid, or gaseous state. One such ADI-MS source, the flowing atmospheric-pressure afterglow (FAPA), is capable of direct analysis of solids just by aiming the source at the solid surface and sampling the produced ions into a mass spectrometer. However, direct introduction of significant volumes of liquid samples into this source has not been possible, as solvent loads can quench the afterglow and, thus, the formation of reagent ions. As a result, the analysis of liquid samples is preferably carried out by analyzing dried residues or by desorbing small amounts of liquid samples directly from the liquid surface. In the former case, reproducibility of sample introduction is crucial if quantitative results are desired. In the present study, introduction of liquid samples as very small droplets helps overcome the issues of sample positioning and reduced levels of solvent intake. A recently developed "drop-on-demand" (DOD) aerosol generator is capable of reproducibly producing very small volumes of liquid (∼17 pL). In this paper, the coupling of FAPA-MS and DOD is reported and applications are suggested. Analytes representing different classes of substances were tested and limits of detections were determined. Matrix tolerance was investigated for drugs of abuse and their metabolites by analyzing raw urine samples and quantification without the use of internal standards. Limits of detection below 2 μg/mL, without sample pretreatment, were obtained.

  6. Measurement of small lesions near metallic implants with mega-voltage cone beam CT

    NASA Astrophysics Data System (ADS)

    Grigorescu, Violeta; Prevrhal, Sven; Pouliot, Jean

    2008-03-01

    Metallic objects severely limit diagnostic CT imaging because of their high X-ray attenuation in the diagnostic energy range. In contrast, radiation therapy linear accelerators now offer CT imaging with X-ray energies in the megavolt range, where the attenuation coefficients of metals are significantly lower. We hypothesized that Mega electron-Voltage Cone-Beam CT (MVCT) implemented on a radiation therapy linear accelerator can detect and quantify small features in the vicinity of metallic implants with accuracy comparable to clinical Kilo electron-Voltage CT (KVCT) for imaging. Our test application was detection of osteolytic lesions formed near the metallic stem of a hip prosthesis, a condition of severe concern in hip replacement surgery. Both MVCT and KVCT were used to image a phantom containing simulated osteolytic bone lesions centered around a Chrome-Cobalt hip prosthesis stem with hemispherical lesions with sizes and densities ranging from 0.5 to 4 mm radius and 0 to 500 mg•cm -3, respectively. Images for both modalities were visually graded to establish lower limits of lesion visibility as a function of their size. Lesion volumes and mean density were determined and compared to reference values. Volume determination errors were reduced from 34%, on KVCT, to 20% for all lesions on MVCT, and density determination errors were reduced from 71% on KVCT to 10% on MVCT. Localization and quantification of lesions was improved with MVCT imaging. MVCT offers a viable alternative to clinical CT in cases where accurate 3D imaging of small features near metallic hardware is critical. These results need to be extended to other metallic objects of different composition and geometry.

  7. How To Set Up Your Own Small Business. Volumes I-II and Overhead Transparencies.

    ERIC Educational Resources Information Center

    Fallek, Max

    This two-volume textbook and collection of overhead transparency masters is intended for use in a course in setting up a small business. The following topics are covered in the first volume: getting off to a good start, doing market research, forecasting sales, financing a small business, understanding the different legal needs of different types…

  8. USEPA MANUAL OF METHODS FOR VIROLOGY | Science ...

    EPA Pesticide Factsheets

    This chapter describes procedures for the detection of coliphases in water matrices. These procedures are based on those presented in the Supplement to the 20th Edition of Standard Methods for the Examination of Water and Eastewater and EPA Methods 1601 and 1602. Two quantitative procedures and one qualitative, presence-absence procedures are presented. The procedures can be used, without supplementary methods, to assay small volumes of water (10 mL to 1L). For larger volumes (>100L), large-scale concentration methods such as described in Chapter 14 may be incorporated into the assay scheme. However, as some concentration procedures may result in appreciable loss or inactivation of coliphage, it is recommended that the suitability of any large volume concentration method be evaluated in measured recovery trials before implementation. Develop sensitive techniques to detect and identify emerging human waterborne pathogenic viruses and viruses on the CCL.Determine effectiveness of viral indicators to measure microbial quality in water matrices.Support activities: (a) culture and distribution of mammalian cells for Agency and scientific community research needs, (b) provide operator expertise for research requiring confocal and electron microscopy, (c) glassware cleaning, sterilization and biological waste disposal for the Cincinnati EPA facility, (d) operation of infectious pathogenic suite, (e) maintenance of walk-in constant temperature rooms and (f) provid

  9. An improved analytical strategy combining microextraction by packed sorbent combined with ultra high pressure liquid chromatography for the determination of fluoxetine, clomipramine and their active metabolites in human urine.

    PubMed

    Alves, Vera; Gonçalves, João; Conceição, Carlota; Teixeira, Helena M; Câmara, José S

    2015-08-21

    A powerful and sensitive method, by microextraction packed sorbent (MEPS), and ultra-high performance liquid chromatography (UHPLC) with a photodiode array (PDA) detection, is described for the determination of fluoxetine, clomipramine and their active metabolites in human urine samples. The MEPS variables, such as sample volume, pH, number of extraction cycles (draw-eject), and desorption conditions (solvent and solvent volume of elution) were optimized. The analysis were carried out using small sample volumes (500μL) and in a short time period (5min for the entire sample preparation step). Good linearity was obtained for all antidepressants with the correlation coefficients (R(2)) above 0.9965. The limits of detection (LOD) ranged from 0.068 to 0.087μgmL(-1). The recoveries were from 93% to 98%, with relative standard deviations less than 6%. The inter-day precision, expressed as the relative standard deviation, varied between 3.8% and 8.5% while the intra-day precision between 3.0% and 7.1%. In order to evaluate the proposed method for clinical use, the MEPS/UHPLC-PDA method was applied to analysis of urine samples from depressed patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Hydration heat of alkali activated fine-grained ceramic

    NASA Astrophysics Data System (ADS)

    Jerman, Miloš; Černý, Robert

    2017-07-01

    Early-age hydration heat of alkali activated ceramic dust is studied as a function of silicate modulus. A mixture of sodium hydroxide and water glass is used as alkali activator. The measurements are carried out using a large-volume isothermal heat flow calorimeter which is capable of detecting even very small values of specific heat power. Experimental results show that the specific hydration heat power of alkali activated fine-ground ceramic is very low and increases with the decreasing silicate modulus of the mix.

  11. Acoustic detection of air shower cores

    NASA Technical Reports Server (NTRS)

    Gao, X.; Liu, Y.; Du, S.

    1985-01-01

    At an altitude of 1890m, a pre-test with an Air shower (AS) core selector and a small acoustic array set up in an anechoic pool with a volume of 20x7x7 cu m was performed, beginning in Aug. 1984. In analyzing the waveforms recorded during the effective working time of 186 hrs, three acoustic signals which cannot be explained as from any source other than AS cores were obtained, and an estimation of related parameters was made.

  12. Minutes of the Explosives Safety Seminar (25th) Held in Anaheim, California on 18-20 August 1992. Volume 1

    DTIC Science & Technology

    1992-08-20

    project. There is no doubt that we would have otherwise spent many years in proving project feasibility and trialing the specific demilitarisation...SUCH ROCKET MOTORS AS THE ONE USED IN THE BULLPUP SYSTEM WERE CONSIDERED. A. DRAINING AND NEUTRALIZING THE OXIDIZER BY CAUSTIC SODA AND THEN SIMPLE...INHIBITED RED FUMING NITRIC ACID WAS DETECTED IN SMALL AMOUNTS. 482 CONSEQUENTLY. THE "EMPTY" CASES WERE PLACED INTO A TANK CONTAINING WATER AND CAUSTIC

  13. Deployable pressurized cell structure for a micrometeoroid detector

    NASA Technical Reports Server (NTRS)

    Kinard, W. H. (Inventor)

    1974-01-01

    This disclosure comprises a plurality of individual pressurized cells which are caused to leak in response to a micrometeoroid penetration, the leak being sensed by appropriate instrumentation. The plurality of cells may be rolled into a compact arrangement such that the volume of the micrometeoroid detector is small and therefore readily packed in a payload of a launch vehicle. Once the payload is placed in orbit, the rolled up cells can be released, pressurized and provide a relatively rigid, large surface area for detecting micrometeoroid penetration.

  14. Defense Small Business Innovation Research Program (SBIR). Volume 3. Air Force Abstracts of Phase 1 Awards

    DTIC Science & Technology

    1990-01-01

    THERE WILL BE A CONTINUING NEED FOR A SENSITIVE, RAPID, AND ECONOMICAL TESTING PROCEDURE CAPABLE OF DETECTING DEFECTS AND PROVIDING FEEDBACK FOR QUALITY...SOLUTIONS. THE DKF METHOD PROVIDES OPTIMAL OR NEAR-OPTIMAL ACCURACY, REDUCE PROCESSING BURDEN, AND IMPROVE FAULT TOLERANCE. THE DKF/MMAE ( DMAE ) TECHNIQUES...DEVICES FOR B-SiC IS TO BE ABLE TO CONSISTENTLY PRODUCE INTRINSIC FILMS WITH VERY LOW DEFECTS AND TO DEVELOP SCHOTTKY AND OHMIC CONTACT MATERIALS THAT WILL

  15. Volume estimation of small phantoms and rat kidneys using three-dimensional ultrasonography and a position sensor.

    PubMed

    Strømmen, Kenneth; Stormark, Tor André; Iversen, Bjarne M; Matre, Knut

    2004-09-01

    To evaluate the accuracy of small volume estimation, both in vivo and in vitro, measurements with a three-dimensional (3D) ultrasound (US) system were carried out. A position sensor was used and the transmitting frequency was 10 MHz. Balloons with known volumes were scanned while rat kidneys were scanned in vivo and in vitro. The Archimedes' principle was used to estimate the true volume. For balloons, the 3D US system gave very good agreement with true volumes in the volume range 0.1 to 10.0 mL (r = 0.999, n = 45, mean difference +/- 2SD = 0.245 +/- 0.370 mL). For rat kidneys in vivo (volume range 0.6 to 2.7 mL) the method was less accurate (r = 0.800, n = 10, mean difference +/- 2SD = -0.288 +/- 0.676 mL). For rat kidneys in vitro (volume range 0.3 to 2.7 mL) the results showed good agreement (r = 0.981, n = 23, mean difference +/- 2SD = 0.039 +/- 0.254 mL). For balloons, kidneys in vivo and in vitro, the mean percentage error was 9.3 +/- 4.8%, -17.1 +/- 17.4%, and 4.6 +/- 11.5%, respectively. This method can estimate the volume of small phantoms and rat kidneys and opens new possibilities for volume measurements of small objects and the study of organ function in small animals. (E-mail ).

  16. Laboratory-Scale Simulation and Real-Time Tracking of a Microbial Contamination Event and Subsequent Shock-Chlorination in Drinking Water

    PubMed Central

    Besmer, Michael D.; Sigrist, Jürg A.; Props, Ruben; Buysschaert, Benjamin; Mao, Guannan; Boon, Nico; Hammes, Frederik

    2017-01-01

    Rapid contamination of drinking water in distribution and storage systems can occur due to pressure drop, backflow, cross-connections, accidents, and bio-terrorism. Small volumes of a concentrated contaminant (e.g., wastewater) can contaminate large volumes of water in a very short time with potentially severe negative health impacts. The technical limitations of conventional, cultivation-based microbial detection methods neither allow for timely detection of such contaminations, nor for the real-time monitoring of subsequent emergency remediation measures (e.g., shock-chlorination). Here we applied a newly developed continuous, ultra high-frequency flow cytometry approach to track a rapid pollution event and subsequent disinfection of drinking water in an 80-min laboratory scale simulation. We quantified total (TCC) and intact (ICC) cell concentrations as well as flow cytometric fingerprints in parallel in real-time with two different staining methods. The ingress of wastewater was detectable almost immediately (i.e., after 0.6% volume change), significantly changing TCC, ICC, and the flow cytometric fingerprint. Shock chlorination was rapid and detected in real time, causing membrane damage in the vast majority of bacteria (i.e., drop of ICC from more than 380 cells μl-1 to less than 30 cells μl-1 within 4 min). Both of these effects as well as the final wash-in of fresh tap water followed calculated predictions well. Detailed and highly quantitative tracking of microbial dynamics at very short time scales and for different characteristics (e.g., concentration, membrane integrity) is feasible. This opens up multiple possibilities for targeted investigation of a myriad of bacterial short-term dynamics (e.g., disinfection, growth, detachment, operational changes) both in laboratory-scale research and full-scale system investigations in practice. PMID:29085343

  17. Development of a rapid and sensitive method combining a cellulose ester microfilter and a real-time quantitative PCR assay to detect Campylobacter jejuni and Campylobacter coli in 20 liters of drinking water or low-turbidity waters.

    PubMed

    Tissier, Adeline; Denis, Martine; Hartemann, Philippe; Gassilloud, Benoît

    2012-02-01

    Investigations of Campylobacter jejuni and Campylobacter coli in samples of drinking water suspected of being at the origin of an outbreak very often lead to negative results. One of the reasons for this failure is the small volume of water typically used for detecting these pathogens (10 to 1,000 ml). The efficiencies of three microfilters and different elution procedures were determined using real-time quantitative PCR to propose a procedure allowing detection of Campylobacter in 20 liters of drinking water or low-turbidity water samples. The results showed that more than 80% of the bacteria inoculated in 1 liter of drinking water were retained on each microfilter. An elution with a solution containing 3% beef extract, 0.05 M glycine at pH 9, combined with direct extraction of the bacterial genomes retained on the cellulose ester microfilter, allowed recovery of 87.3% (±22% [standard deviation]) of Campylobacter per 1 liter of tap water. Recoveries obtained from 20-liter volumes of tap water spiked with a C. coli strain were 69.5% (±10.3%) and 78.5% (±15.1%) for 91 CFU and 36 CFU, respectively. Finally, tests performed on eight samples of 20 liters of groundwater collected from an alluvial well used for the production of drinking water revealed the presence of C. jejuni and C. coli genomes, whereas no bacteria were detected with the normative culture method in volumes ranging from 10 to 1,000 ml. In the absence of available epidemiological data and information on bacterial viability, these last results indicate only that the water resource is not protected from contamination by Campylobacter.

  18. Development of a Rapid and Sensitive Method Combining a Cellulose Ester Microfilter and a Real-Time Quantitative PCR Assay To Detect Campylobacter jejuni and Campylobacter coli in 20 Liters of Drinking Water or Low-Turbidity Waters

    PubMed Central

    Tissier, Adeline; Denis, Martine; Hartemann, Philippe

    2012-01-01

    Investigations of Campylobacter jejuni and Campylobacter coli in samples of drinking water suspected of being at the origin of an outbreak very often lead to negative results. One of the reasons for this failure is the small volume of water typically used for detecting these pathogens (10 to 1,000 ml). The efficiencies of three microfilters and different elution procedures were determined using real-time quantitative PCR to propose a procedure allowing detection of Campylobacter in 20 liters of drinking water or low-turbidity water samples. The results showed that more than 80% of the bacteria inoculated in 1 liter of drinking water were retained on each microfilter. An elution with a solution containing 3% beef extract, 0.05 M glycine at pH 9, combined with direct extraction of the bacterial genomes retained on the cellulose ester microfilter, allowed recovery of 87.3% (±22% [standard deviation]) of Campylobacter per 1 liter of tap water. Recoveries obtained from 20-liter volumes of tap water spiked with a C. coli strain were 69.5% (±10.3%) and 78.5% (±15.1%) for 91 CFU and 36 CFU, respectively. Finally, tests performed on eight samples of 20 liters of groundwater collected from an alluvial well used for the production of drinking water revealed the presence of C. jejuni and C. coli genomes, whereas no bacteria were detected with the normative culture method in volumes ranging from 10 to 1,000 ml. In the absence of available epidemiological data and information on bacterial viability, these last results indicate only that the water resource is not protected from contamination by Campylobacter. PMID:22138985

  19. Voxel-based morphometry and automated lobar volumetry: The trade-off between spatial scale and statistical correction

    PubMed Central

    Voormolen, Eduard H.J.; Wei, Corie; Chow, Eva W.C.; Bassett, Anne S.; Mikulis, David J.; Crawley, Adrian P.

    2011-01-01

    Voxel-based morphometry (VBM) and automated lobar region of interest (ROI) volumetry are comprehensive and fast methods to detect differences in overall brain anatomy on magnetic resonance images. However, VBM and automated lobar ROI volumetry have detected dissimilar gray matter differences within identical image sets in our own experience and in previous reports. To gain more insight into how diverging results arise and to attempt to establish whether one method is superior to the other, we investigated how differences in spatial scale and in the need to statistically correct for multiple spatial comparisons influence the relative sensitivity of either technique to group differences in gray matter volumes. We assessed the performance of both techniques on a small dataset containing simulated gray matter deficits and additionally on a dataset of 22q11-deletion syndrome patients with schizophrenia (22q11DS-SZ) vs. matched controls. VBM was more sensitive to simulated focal deficits compared to automated ROI volumetry, and could detect global cortical deficits equally well. Moreover, theoretical calculations of VBM and ROI detection sensitivities to focal deficits showed that at increasing ROI size, ROI volumetry suffers more from loss in sensitivity than VBM. Furthermore, VBM and automated ROI found corresponding GM deficits in 22q11DS-SZ patients, except in the parietal lobe. Here, automated lobar ROI volumetry found a significant deficit only after a smaller subregion of interest was employed. Thus, sensitivity to focal differences is impaired relatively more by averaging over larger volumes in automated ROI methods than by the correction for multiple comparisons in VBM. These findings indicate that VBM is to be preferred over automated lobar-scale ROI volumetry for assessing gray matter volume differences between groups. PMID:19619660

  20. Phylogenetic ctDNA analysis depicts early stage lung cancer evolution

    PubMed Central

    Abbosh, Christopher; Birkbak, Nicolai J.; Wilson, Gareth A.; Jamal-Hanjani, Mariam; Constantin, Tudor; Salari, Raheleh; Le Quesne, John; Moore, David A; Veeriah, Selvaraju; Rosenthal, Rachel; Marafioti, Teresa; Kirkizlar, Eser; Watkins, Thomas B K; McGranahan, Nicholas; Ward, Sophia; Martinson, Luke; Riley, Joan; Fraioli, Francesco; Al Bakir, Maise; Grönroos, Eva; Zambrana, Francisco; Endozo, Raymondo; Bi, Wenya Linda; Fennessy, Fiona M.; Sponer, Nicole; Johnson, Diana; Laycock, Joanne; Shafi, Seema; Czyzewska-Khan, Justyna; Rowan, Andrew; Chambers, Tim; Matthews, Nik; Turajlic, Samra; Hiley, Crispin; Lee, Siow Ming; Forster, Martin D.; Ahmad, Tanya; Falzon, Mary; Borg, Elaine; Lawrence, David; Hayward, Martin; Kolvekar, Shyam; Panagiotopoulos, Nikolaos; Janes, Sam M; Thakrar, Ricky; Ahmed, Asia; Blackhall, Fiona; Summers, Yvonne; Hafez, Dina; Naik, Ashwini; Ganguly, Apratim; Kareht, Stephanie; Shah, Rajesh; Joseph, Leena; Quinn, Anne Marie; Crosbie, Phil; Naidu, Babu; Middleton, Gary; Langman, Gerald; Trotter, Simon; Nicolson, Marianne; Remmen, Hardy; Kerr, Keith; Chetty, Mahendran; Gomersall, Lesley; Fennell, Dean; Nakas, Apostolos; Rathinam, Sridhar; Anand, Girija; Khan, Sajid; Russell, Peter; Ezhil, Veni; Ismail, Babikir; Irvin-sellers, Melanie; Prakash, Vineet; Lester, Jason; Kornaszewska, Malgorzata; Attanoos, Richard; Adams, Haydn; Davies, Helen; Oukrif, Dahmane; Akarca, Ayse U; Hartley, John A; Lowe, Helen L; Lock, Sara; Iles, Natasha; Bell, Harriet; Ngai, Yenting; Elgar, Greg; Szallasi, Zoltan; Schwarz, Roland F; Herrero, Javier; Stewart, Aengus; Quezada, Sergio A; Peggs, Karl S.; Van Loo, Peter; Dive, Caroline; Lin, Jimmy; Rabinowitz, Matthew; Aerts, Hugo JWL; Hackshaw, Allan; Shaw, Jacqui A; Zimmermann, Bernhard G.; Swanton, Charles

    2017-01-01

    Summary The early detection of relapse following primary surgery for non-small cell lung cancer and the characterization of emerging subclones seeding metastatic sites might offer new therapeutic approaches to limit tumor recurrence. The potential to non-invasively track tumor evolutionary dynamics in ctDNA of early-stage lung cancer is not established. Here we conduct a tumour-specific phylogenetic approach to ctDNA profiling in the first 100 TRACERx (TRAcking non-small cell lung Cancer Evolution through therapy (Rx)) study participants, including one patient co-recruited to the PEACE (Posthumous Evaluation of Advanced Cancer Environment) post-mortem study. We identify independent predictors of ctDNA release and perform tumor volume limit of detection analyses. Through blinded profiling of post-operative plasma, we observe evidence of adjuvant chemotherapy resistance and identify patients destined to experience recurrence of their lung cancer. Finally, we show that phylogenetic ctDNA profiling tracks the subclonal nature of lung cancer relapse and metastases, providing a new approach for ctDNA driven therapeutic studies PMID:28445469

  1. Cystic echinococcosis in a wild population of the brush-tailed rock-wallaby (Petrogale penicillata), a threatened macropodid.

    PubMed

    Barnes, T S; Goldizen, A W; Morton, J M; Coleman, G T

    2008-05-01

    Infection of small macropodids with the larval stage of Echinococcus granulosus can cause fatalities as well as significant pulmonary impairment and other adverse sequelae. The brush-tailed rock-wallaby (Petrogale penicillata) is a small macropodid listed as vulnerable on the IUCN's Red List of Threatened Species. This study used radiographic techniques to determine the prevalence and severity of pulmonary hydatid infection and growth rates of hydatid cysts in a wild population of this macropodid. The overall prevalence was 15.3% (9/59 animals) with 20.0% (8/40 animals) of adults infected. During the study period, the death of at least 1 infected animal was directly attributed to pulmonary hydatidosis. Rapid cyst growth occurred in some animals (up to 43% increase in cyst volume in 3 months). Cyst volume reduced lung capacity by up to 17%. Secondary pulmonary changes were uncommon but, in 1 animal, resulted in reduction in lung capacity by approximately 50%. Infection was associated with a higher blood urea concentration, but no significant differences in other blood variables were detected. These results indicate that hydatid infection may be a significant risk to threatened populations of small macropodids and should be addressed in conservation management plans for these animals.

  2. Femtomole-Scale High-Throughput Screening of Protein Ligands with Droplet-Based Thermal Shift Assay.

    PubMed

    Liu, Wen-Wen; Zhu, Ying; Fang, Qun

    2017-06-20

    There is a great demand to measure protein-ligand interactions in rapid and low cost way. Here, we developed a microfluidic droplet-based thermal shift assay (dTSA) system for high-throughput screening of small-molecule protein ligands. The system is composed of a nanoliter droplet array chip, a microfluidic droplet robot, and a real-time fluorescence detection system. Total 324 assays could be performed in parallel in a single chip with an 18 × 18 droplet array. The consumption of dTSA for each protein or ligand sample was only 5 nL (femtomole scale), which is significantly reduced by over 3 orders of magnitude compared with those in 96- or 384-well plate-based systems. We also observed the implementation of TSA in nanoliter droplet format could substantially improve assay precision with relative standard deviation (RSD) of 0.2% (n = 50), which can be ascribed to the enhanced thermal conduction in small volume reactors. The dTSA system was optimized by studying the effect of droplet volumes, as well as protein and fluorescent dye (SYPRO Orange) concentrations. To demonstrate its potential in drug discovery, we applied the dTSA system in screening inhibitors of human thrombin with a commercial library containing 100 different small molecule compounds, and two inhibitors were successfully identified and confirmed.

  3. High resolution gas volume change sensor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dirckx, Joris J. J.; Aernouts, Jef E. F.; Aerts, Johan R. M.

    2007-05-15

    Changes of gas quantity in a system can be measured either by measuring pressure changes or by measuring volume changes. As sensitive pressure sensors are readily available, pressure change is the commonly used technique. In many physiologic systems, however, buildup of pressure influences the gas exchange mechanisms, thus changing the gas quantity change rate. If one wants to study the gas flow in or out of a biological gas pocket, measurements need to be done at constant pressure. In this article we present a highly sensitive sensor for quantitative measurements of gas volume change at constant pressure. The sensor ismore » based on optical detection of the movement of a droplet of fluid enclosed in a capillary. The device is easy to use and delivers gas volume data at a rate of more than 15 measurements/s and a resolution better than 0.06 {mu}l. At the onset of a gas quantity change the sensor shows a small pressure artifact of less than 15 Pa, and at constant change rates the pressure artifact is smaller than 10 Pa or 0.01% of ambient pressure.« less

  4. Determination of polycyclic aromatic hydrocarbons in drinking water samples by solid-phase nanoextraction and high-performance liquid chromatography.

    PubMed

    Wang, Huiyong; Campiglia, Andres D

    2008-11-01

    A novel alternative is presented for the extraction and preconcentration of polycyclic aromatic hydrocarbons (PAH) from water samples. The new approachwhich we have named solid-phase nanoextraction (SPNE)takes advantage of the strong affinity that exists between PAH and gold nanoparticles. Carefully optimization of experimental parameters has led to a high-performance liquid chromatography method with excellent analytical figures of merit. Its most striking feature correlates to the small volume of water sample (500 microL) for complete PAH analyses. The limits of detection ranged from 0.9 (anthracene) to 58 ng.L (-1) (fluorene). The relative standard deviations at medium calibration concentrations vary from 3.2 (acenaphthene) to 9.1% (naphthalene). The analytical recoveries from tap water samples of the six regulated PAH varied from 83.3 +/- 2.4 (benzo[ k]fluoranthene) to 95.7 +/- 4.1% (benzo[ g,h,i]perylene). The entire extraction procedure consumes less than 100 microL of organic solvents per sample, which makes it environmentally friendly. The small volume of extracting solution makes SPNE a relatively inexpensive extraction approach.

  5. Automatic Thickness and Volume Estimation of Sprayed Concrete on Anchored Retaining Walls from Terrestrial LIDAR Data

    NASA Astrophysics Data System (ADS)

    Martínez-Sánchez, J.; Puente, I.; GonzálezJorge, H.; Riveiro, B.; Arias, P.

    2016-06-01

    When ground conditions are weak, particularly in free formed tunnel linings or retaining walls, sprayed concrete can be applied on the exposed surfaces immediately after excavation for shotcreting rock outcrops. In these situations, shotcrete is normally applied conjointly with rock bolts and mesh, thereby supporting the loose material that causes many of the small ground falls. On the other hand, contractors want to determine the thickness and volume of sprayed concrete for both technical and economic reasons: to guarantee their structural strength but also, to not deliver excess material that they will not be paid for. In this paper, we first introduce a terrestrial LiDAR-based method for the automatic detection of rock bolts, as typically used in anchored retaining walls. These ground support elements are segmented based on their geometry and they will serve as control points for the co-registration of two successive scans, before and after shotcreting. Then we compare both point clouds to estimate the sprayed concrete thickness and the expending volume on the wall. This novel methodology is demonstrated on repeated scan data from a retaining wall in the city of Vigo (Spain), resulting in a rock bolts detection rate of 91%, that permits to obtain a detailed information of the thickness and calculate a total volume of 3597 litres of concrete. These results have verified the effectiveness of the developed approach by increasing productivity and improving previous empirical proposals for real time thickness estimation.

  6. 2.5D change detection from satellite imagery to monitor small-scale mining activities in the Democratic Republic of the Congo

    NASA Astrophysics Data System (ADS)

    Kranz, Olaf; Lang, Stefan; Schoepfer, Elisabeth

    2017-09-01

    Mining natural resources serve fundamental societal needs or commercial interests, but it may well turn into a driver of violence and regional instability. In this study, very high resolution (VHR) optical stereo satellite data are analysed to monitor processes and changes in one of the largest artisanal and small-scale mining sites in the Democratic Republic of the Congo, which is among the world's wealthiest countries in exploitable minerals To identify the subtle structural changes, the applied methodological framework employs object-based change detection (OBCD) based on optical VHR data and generated digital surface models (DSM). Results prove the DSM-based change detection approach enhances the assessment gained from sole 2D analyses by providing valuable information about changes in surface structure or volume. Land cover changes as analysed by OBCD reveal an increase in bare soil area by a rate of 47% between April 2010 and September 2010, followed by a significant decrease of 47.5% until March 2015. Beyond that, DSM differencing enabled the characterisation of small-scale features such as pits and excavations. The presented Earth observation (EO)-based monitoring of mineral exploitation aims at a better understanding of the relations between resource extraction and conflict, and thus providing relevant information for potential mitigation strategies and peace building.

  7. State-of-the-art magnetic resonance imaging of pancreatic cancer.

    PubMed

    Schima, Wolfgang; Ba-Ssalamah, Ahmed; Goetzinger, Peter; Scharitzer, Martina; Koelblinger, Claus

    2007-12-01

    Technical advances of magnetic resonance imaging (MRI), including ultrahigh-field magnetic resonance at 3.0 T, parallel imaging techniques, and multichannel receive coils of the abdomen, have promoted MRI of the pancreas. For adenocarcinoma, which is the most common malignant pancreatic tumor, helical CT has been most often used for detection and staging, but it has limitations in the detection of small cancers 2 cm in diameter or less (sensitivity, 63%). Moreover, it is not very accurate in determining nonresectability, because small liver metastases, peritoneal carcinomatosis, and subtle signs of vascular infiltration may be missed. At ultrahigh field at 3.0 T, gadolinium-enhanced MRI using volume-interpolated 3-dimensional gradient-recalled echo pulse sequences with near-isotropic voxels are very useful for detection of subtle abnormalities. Mangafodipir-enhanced MRI reveals a very high tumor-pancreas contrast, which helps to diagnose small cancers. Contrast-enhanced MRI is a problem-solving tool in case of equivocal CT: it helps to differentiate between cancer and focal pancreatitis. Neuroendocrine carcinoma may present with a spectrum of appearances at MRI, but the primary tumor and liver metastases are hypervascular in approximately 70%. In this article, pancreas imaging protocols for 1.5 and 3.0 T are explained. We present the imaging features of pancreatic cancer and the important questions in staging, which should be addressed by the radiologist.

  8. Small tractors for harvesting fuelwood in low-volume small-diameter hardwood stands

    Treesearch

    Neil K. Huyler; Chris B. LeDoux

    1989-01-01

    Much of the nonindustrial, private forest land in the Northeast is characterized by small diameter trees with low volume. Conventional harvesting systems used in logging these stands generally results in submarginal economic returns. Often, small-scale harvesting systems have economic advantages in these areas. Time and motion studies were conducted for several small...

  9. Method for preparing small volume reaction containers

    DOEpatents

    Retterer, Scott T.; Doktycz, Mitchel J.

    2017-04-25

    Engineered reaction containers that can be physically and chemically defined to control the flux of molecules of different sizes and charge are disclosed. Methods for constructing small volume reaction containers through a combination of etching and deposition are also disclosed. The methods allow for the fabrication of multiple devices that possess features on multiple length scales, specifically small volume containers with controlled porosity on the nanoscale.

  10. Influence of Adaptive Statistical Iterative Reconstruction on coronary plaque analysis in coronary computed tomography angiography.

    PubMed

    Precht, Helle; Kitslaar, Pieter H; Broersen, Alexander; Dijkstra, Jouke; Gerke, Oke; Thygesen, Jesper; Egstrup, Kenneth; Lambrechtsen, Jess

    The purpose of this study was to study the effect of iterative reconstruction (IR) software on quantitative plaque measurements in coronary computed tomography angiography (CCTA). Thirty patients with a three clinical risk factors for coronary artery disease (CAD) had one CCTA performed. Images were reconstructed using FBP, 30% and 60% adaptive statistical IR (ASIR). Coronary plaque analysis was performed as per patient and per vessel (LM, LAD, CX and RCA) measurements. Lumen and vessel volumes and plaque burden measurements were based on automatic detected contours in each reconstruction. Lumen and plaque intensity measurements and HU based plaque characterization were based on corrected contours copied to each reconstruction. No significant changes between FBP and 30% ASIR were found except for lumen- (-2.53 HU) and plaque intensities (-1.28 HU). Between FBP and 60% ASIR the change in total volume showed an increase of 0.94%, 4.36% and 2.01% for lumen, plaque and vessel, respectively. The change in total plaque burden between FBP and 60% ASIR was 0.76%. Lumen and plaque intensities decreased between FBP and 60% ASIR with -9.90 HU and -1.97 HU, respectively. The total plaque component volume changes were all small with a maximum change of -1.13% of necrotic core between FBP and 60% ASIR. Quantitative plaque measurements only showed modest differences between FBP and the 60% ASIR level. Differences were increased lumen-, vessel- and plaque volumes, decreased lumen- and plaque intensities and a small percentage change in the individual plaque component volumes. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  11. Small Business Management and Ownership. Volume Four. Mini-Problems in Entrepreneurship.

    ERIC Educational Resources Information Center

    Shuchat, Jo

    The mini-problems presented in this volume are provided to augment the introductory course, "Minding Your Own Small Business," and the advanced course, "Something Ventured, Something Gained," in small business ownership and management. They can also be used in conjunction with other instructional materials in small business…

  12. Array Formatting of the Heat-Transfer Method (HTM) for the Detection of Small Organic Molecules by Molecularly Imprinted Polymers

    PubMed Central

    Wackers, Gideon; Vandenryt, Thijs; Cornelis, Peter; Kellens, Evelien; Thoelen, Ronald; De Ceuninck, Ward; Losada-Pérez, Patricia; van Grinsven, Bart; Peeters, Marloes; Wagner, Patrick

    2014-01-01

    In this work we present the first steps towards a molecularly imprinted polymer (MIP)-based biomimetic sensor array for the detection of small organic molecules via the heat-transfer method (HTM). HTM relies on the change in thermal resistance upon binding of the target molecule to the MIP-type receptor. A flow-through sensor cell was developed, which is segmented into four quadrants with a volume of 2.5 μL each, allowing four measurements to be done simultaneously on a single substrate. Verification measurements were conducted, in which all quadrants received a uniform treatment and all four channels exhibited a similar response. Subsequently, measurements were performed in quadrants, which were functionalized with different MIP particles. Each of these quadrants was exposed to the same buffer solution, spiked with different molecules, according to the MIP under analysis. With the flow cell design we could discriminate between similar small organic molecules and observed no significant cross-selectivity. Therefore, the MIP array sensor platform with HTM as a readout technique, has the potential to become a low-cost analysis tool for bioanalytical applications. PMID:24955945

  13. Quantifying viruses and bacteria in wastewater—Results, interpretation methods, and quality control

    USGS Publications Warehouse

    Francy, Donna S.; Stelzer, Erin A.; Bushon, Rebecca N.; Brady, Amie M.G.; Mailot, Brian E.; Spencer, Susan K.; Borchardt, Mark A.; Elber, Ashley G.; Riddell, Kimberly R.; Gellner, Terry M.

    2011-01-01

    Membrane bioreactors (MBR), used for wastewater treatment in Ohio and elsewhere in the United States, have pore sizes small enough to theoretically reduce concentrations of protozoa and bacteria, but not viruses. Sampling for viruses in wastewater is seldom done and not required. Instead, the bacterial indicators Escherichia coli (E. coli) and fecal coliforms are the required microbial measures of effluents for wastewater-discharge permits. Information is needed on the effectiveness of MBRs in removing human enteric viruses from wastewaters, particularly as compared to conventional wastewater treatment before and after disinfection. A total of 73 regular and 28 quality-control (QC) samples were collected at three MBR and two conventional wastewater plants in Ohio during 23 regular and 3 QC sampling trips in 2008-10. Samples were collected at various stages in the treatment processes and analyzed for bacterial indicators E. coli, fecal coliforms, and enterococci by membrane filtration; somatic and F-specific coliphage by the single agar layer (SAL) method; adenovirus, enterovirus, norovirus GI and GII, rotavirus, and hepatitis A virus by molecular methods; and viruses by cell culture. While addressing the main objective of the study-comparing removal of viruses and bacterial indicators in MBR and conventional plants-it was realized that work was needed to identify data analysis and quantification methods for interpreting enteric virus and QC data. Therefore, methods for quantifying viruses, qualifying results, and applying QC data to interpretations are described in this report. During each regular sampling trip, samples were collected (1) before conventional or MBR treatment (post-preliminary), (2) after secondary or MBR treatment (post-secondary or post-MBR), (3) after tertiary treatment (one conventional plant only), and (4) after disinfection (post-disinfection). Glass-wool fiber filtration was used to concentrate enteric viruses from large volumes, and small volume grab samples were collected for direct-plating analyses for bacterial indicators and coliphage. After filtration, the viruses were eluted from the filter and further concentrated. The final concentrated sample volume (FCSV) was used for enteric virus analysis by use of two methods-cell culture and a molecular method, polymerase chain reaction (PCR). Quantitative PCR (qPCR) for DNA viruses and quantitative reverse-transcriptase PCR (qRT-PCR) for RNA viruses were used in this study. To support data interpretations, the assay limit of detection (ALOD) was set for each virus assay and used to determine sample reporting limits (SRLs). For qPCR and qRT-PCR the ALOD was an estimated value because it was not established according to established method detection limit procedures. The SRLs were different for each sample because effective sample volumes (the volume of the original sample that was actually used in each analysis) were different for each sample. Effective sample volumes were much less than the original sample volumes because of reductions from processing steps and (or) from when dilutions were made to minimize the effects from PCR-inhibiting substances. Codes were used to further qualify the virus data and indicate the level of uncertainty associated with each measurement. Quality-control samples were used to support data interpretations. Field and laboratory blanks for bacteria, coliphage, and enteric viruses were all below detection, indicating that it was unlikely that samples were contaminated from equipment or processing procedures. The absolute value log differences (AVLDs) between concurrent replicate pairs were calculated to identify the variability associated with each measurement. For bacterial indicators and coliphage, the AVLD results indicated that concentrations <10 colony-forming units or plaque-forming units per 100 mL can differ between replicates by as much as 1 log, whereas higher concentrations can differ by as much as 0.3 log. The AVLD results for viruses indicated that differences between replicates can be as great as 1.2 log genomic copies per liter, regardless of the concentration of virus. Relatively large differences in molecular results for viruses between replicate pairs were likely due to lack of precision for samples with small effective volumes. Concentrations of E. coli, fecal coliforms, enterococci, and somatic and F-specific coliphage in post-secondary and post-tertiary samples in conventional plants were higher than those in post-MBR samples. In post-MBR and post-secondary samples, concentrations of somatic coliphage were higher than F-specific coliphage. In post-disinfection samples from two MBR plants (the third MBR plant had operational issues) and the ultraviolet conventional plant, concentrations for all bacterial indicators and coliphage were near or below detection; from the chlorine conventional plant, concentrations in post-disinfection samples were in the single or double digits. All of the plants met the National Pollutant Discharge Elimination System required effluent limits established for fecal coliforms. Norovirus GII and hepatitis A virus were not detected in any samples, and rotavirus was detected in one sample but could not be quantified. Adenovirus was found in 100 percent, enterovirus in over one-half, and norovirus GI in about one-half of post-preliminary wastewater samples. Adenovirus and enterovirus were detected throughout the treatment processes, and norovirus GI was detected less often than the other two enteric viruses. Culturable viruses were detected in post-preliminary samples and in only two post-treatment samples from the plant with operational issues.

  14. Microfluidic cantilever detects bacteria and measures their susceptibility to antibiotics in small confined volumes

    NASA Astrophysics Data System (ADS)

    Etayash, Hashem; Khan, M. F.; Kaur, Kamaljit; Thundat, Thomas

    2016-10-01

    In the fight against drug-resistant bacteria, accurate and high-throughput detection is essential. Here, a bimaterial microcantilever with an embedded microfluidic channel with internal surfaces chemically or physically functionalized with receptors selectively captures the bacteria passing through the channel. Bacterial adsorption inside the cantilever results in changes in the resonance frequency (mass) and cantilever deflection (adsorption stress). The excitation of trapped bacteria using infrared radiation (IR) causes the cantilever to deflect in proportion to the infrared absorption of the bacteria, providing a nanomechanical infrared spectrum for selective identification. We demonstrate the in situ detection and discrimination of Listeria monocytogenes at a concentration of single cell per μl. Trapped Escherichia coli in the microchannel shows a distinct nanomechanical response when exposed to antibiotics. This approach, which combines enrichment with three different modes of detection, can serve as a platform for the development of a portable, high-throughput device for use in the real-time detection of bacteria and their response to antibiotics.

  15. Impact of FDG-PET on radiation therapy volume delineation in non-small-cell lung cancer.

    PubMed

    Bradley, Jeffrey; Thorstad, Wade L; Mutic, Sasa; Miller, Tom R; Dehdashti, Farrokh; Siegel, Barry A; Bosch, Walter; Bertrand, Rudi J

    2004-05-01

    Locoregional failure remains a significant problem for patients receiving definitive radiation therapy alone or combined with chemotherapy for non-small-cell lung cancer (NSCLC). Positron emission tomography (PET) with [(18)F]fluoro-2-deoxy-d-glucose (FDG) has proven to be a valuable diagnostic and staging tool for NSCLC. This prospective study was performed to determine the impact of treatment simulation with FDG-PET and CT on radiation therapy target volume definition and toxicity profiles by comparison to simulation with computed tomography (CT) scanning alone. Twenty-six patients with Stages I-III NSCLC were studied. Each patient underwent sequential CT and FDG-PET simulation on the same day. Immobilization devices used for both simulations included an alpha cradle, a flat tabletop, 6 external fiducial markers, and a laser positioning system. A radiation therapist participated in both simulations to reproduce the treatment setup. Both the CT and fused PET/CT image data sets were transferred to the radiation treatment planning workstation for contouring. Each FDG-PET study was reviewed with the interpreting nuclear radiologist before tumor volumes were contoured. The fused PET/CT images were used to develop the three-dimensional conformal radiation therapy (3DCRT) plan. A second physician, blinded to the results of PET, contoured the gross tumor volumes (GTV) and planning target volumes (PTV) from the CT data sets, and these volumes were used to generate mock 3DCRT plans. The PTV was defined by a 10-mm margin around the GTV. The two 3DCRT plans for each patient were compared with respect to the GTV, PTV, mean lung dose, volume of normal lung receiving > or =20 Gy (V20), and mean esophageal dose. The FDG-PET findings altered the AJCC TNM stage in 8 of 26 (31%) patients; 2 patients were diagnosed with metastatic disease based on FDG-PET and received palliative radiation therapy. Of the 24 patients who were planned with 3DCRT, PET clearly altered the radiation therapy volume in 14 (58%), as follows. PET helped to distinguish tumor from atelectasis in all 3 patients with atelectasis. Unsuspected nodal disease was detected by PET in 10 patients, and 1 patient had a separate tumor focus detected within the same lobe of the lung. Increases in the target volumes led to increases in the mean lung dose, V20, and mean esophageal dose. Decreases in the target volumes in the patients with atelectasis led to decreases in these normal-tissue toxicity parameters. Radiation targeting with fused FDG-PET and CT images resulted in alterations in radiation therapy planning in over 50% of patients by comparison with CT targeting. The increasing availability of integrated PET/CT units will facilitate the use of this technology for radiation treatment planning. A confirmatory multicenter, cooperative group trial is planned within the Radiation Therapy Oncology Group.

  16. Characterising the grey matter correlates of leukoaraiosis in cerebral small vessel disease.

    PubMed

    Lambert, Christian; Sam Narean, Janakan; Benjamin, Philip; Zeestraten, Eva; Barrick, Thomas R; Markus, Hugh S

    2015-01-01

    Cerebral small vessel disease (SVD) is a heterogeneous group of pathological disorders that affect the small vessels of the brain and are an important cause of cognitive impairment. The ischaemic consequences of this disease can be detected using MRI, and include white matter hyperintensities (WMH), lacunar infarcts and microhaemorrhages. The relationship between SVD disease severity, as defined by WMH volume, in sporadic age-related SVD and cortical thickness has not been well defined. However, regional cortical thickness change would be expected due to associated phenomena such as underlying ischaemic white matter damage, and the observation that widespread cortical thinning is observed in the related genetic condition CADASIL (Righart et al., 2013). Using MRI data, we have developed a semi-automated processing pipeline for the anatomical analysis of individuals with cerebral small vessel disease and applied it cross-sectionally to 121 subjects diagnosed with this condition. Using a novel combined automated white matter lesion segmentation algorithm and lesion repair step, highly accurate warping to a group average template was achieved. The volume of white matter affected by WMH was calculated, and used as a covariate of interest in a voxel-based morphometry and voxel-based cortical thickness analysis. Additionally, Gaussian Process Regression (GPR) was used to assess if the severity of SVD, measured by WMH volume, could be predicted from the morphometry and cortical thickness measures. We found significant (Family Wise Error corrected p < 0.05) volumetric decline with increasing lesion load predominately in the parietal lobes, anterior insula and caudate nuclei bilaterally. Widespread significant cortical thinning was found bilaterally in the dorsolateral prefrontal, parietal and posterio-superior temporal cortices. These represent distinctive patterns of cortical thinning and volumetric reduction compared to ageing effects in the same cohort, which exhibited greater changes in the occipital and sensorimotor cortices. Using GPR, the absolute WMH volume could be significantly estimated from the grey matter density and cortical thickness maps (Pearson's coefficients 0.80 and 0.75 respectively). We demonstrate that SVD severity is associated with regional cortical thinning. Furthermore a quantitative measure of SVD severity (WMH volume) can be predicted from grey matter measures, supporting an association between white and grey matter damage. The pattern of cortical thinning and volumetric decline is distinctive for SVD severity compared to ageing. These results, taken together, suggest that there is a phenotypic pattern of atrophy associated with SVD severity.

  17. Neutral particle beam sensing and steering

    DOEpatents

    Maier, II, William B.; Cobb, Donald D.; Robiscoe, Richard T.

    1991-01-01

    The direction of a neutral particle beam (NPB) is determined by detecting Ly.alpha. radiation emitted during motional quenching of excited H(2S) atoms in the beam during movement of the atoms through a magnetic field. At least one detector is placed adjacent the beam exit to define an optical axis that intercepts the beam at a viewing angle to include a volume generating a selected number of photons for detection. The detection system includes a lens having an area that is small relative to the NPB area and a pixel array located in the focal plane of the lens. The lens viewing angle and area pixel array are selected to optimize the beam tilt sensitivity. In one embodiment, two detectors are placed coplanar with the beam axis to generate a difference signal that is insensitive to beam variations other than beam tilt.

  18. Normal tissue toxicity after small field hypofractionated stereotactic body radiation.

    PubMed

    Milano, Michael T; Constine, Louis S; Okunieff, Paul

    2008-10-31

    Stereotactic body radiation (SBRT) is an emerging tool in radiation oncology in which the targeting accuracy is improved via the detection and processing of a three-dimensional coordinate system that is aligned to the target. With improved targeting accuracy, SBRT allows for the minimization of normal tissue volume exposed to high radiation dose as well as the escalation of fractional dose delivery. The goal of SBRT is to minimize toxicity while maximizing tumor control. This review will discuss the basic principles of SBRT, the radiobiology of hypofractionated radiation and the outcome from published clinical trials of SBRT, with a focus on late toxicity after SBRT. While clinical data has shown SBRT to be safe in most circumstances, more data is needed to refine the ideal dose-volume metrics.

  19. Detection of lipopolysaccharides in serum using a waveguide-based optical biosensor

    NASA Astrophysics Data System (ADS)

    Noormohamed, Aneesa; Stromberg, Loreen R.; Anderson, Aaron S.; Karim, Zachary; Dighe, Priya; Kempaiah, Prakasha; Ong'echa, John M.; Perkins, Douglas J.; Doggett, Norman; McMahon, Benjamin; Mukundan, Harshini

    2017-02-01

    Direct ultra-sensitive detection of pathogen biomarkers in blood could provide a universal strategy for diagnosis of bacterial infections, which remain a leading cause of morbidity and mortality in many areas of the world. Many factors complicate diagnosis, including the presence of multiple co-infections in a given patient, and lack of infrastructure in rural settings. In some pediatric patients, such as those in areas with poor resources, an additional challenge exists with low sample volumes due to age and other health factors such as anemia and dehydration. Our team is working on developing novel diagnostic assays, with a waveguide-based biosensor platform, to rapidly and specifically identify pathogen biomarkers from small samples of serum or plasma, allowing for the timely and sensitive diagnosis of infection at the point of care. In addition to the platform, we have developed novel membrane insertion and lipoprotein capture assay methods, to capture lipidated pathogen biomarkers in aqueous blood, by virtue of their interactions with host lipoprotein carriers. Herein, we demonstrate our efforts to adapt the lipoprotein capture assay for the detection of small concentrations of pathogen-secreted lipopolysaccharides in aqueous blood, with the ultimate aim of diagnosing Gram-negative infections effectively.

  20. In2O3 nanowire based field effect transistor for biological sensors.

    NASA Astrophysics Data System (ADS)

    Zeng, Zhongming; Wang, Kai; Zhou, Weilie

    2008-03-01

    Semiconductor nanowires (NWs) are attracting considerable attention due to their nanoscale dimensions and enormous surface-to-volume ratios. Many applications have been demonstrated in toxic gas, protein, small molecule and viruses sensing because of their superior sensing performances. Indium oxide (In2O3) NWs have been successfully applied for toxic gas and small organic molecule sensing. In our experiment, In2O3 NWs based field effect transistors (FET) are fabricated for virus (Ricin) detections. Single-crystalline In2O3 NWs with diameters around 100 nm were synthesized by the thermal evaporation. The nanodevice based on In2O3 NWs bridges the source/drain electrodes with a channel length of ˜5 μm. Basic transport properties of devices were measured before biological detection. The I-V curves with the gate voltage Vg=0 shows good ohmic contact and the resistance is about 10 Mφ. The back-gate effect on the conductivity showed that In2O3 NW is working as n-type channel with obvious back-gate effect, which is much stronger than the reported results. The nanodevices used as virus detection will be also discussed.

  1. Real-time 3D ultrasound guidance of autonomous surgical robot for shrapnel detection and breast biopsy

    NASA Astrophysics Data System (ADS)

    Rogers, Albert J.; Light, Edward D.; von Allmen, Daniel; Smith, Stephen W.

    2009-02-01

    Two studies have been conducted using real time 3D ultrasound and an automated robot system for carrying out surgical tasks. The first task is to perform a breast lesion biopsy automatically after detection by ultrasound. Combining 3D ultrasound with traditional mammography allows real time guidance of the biopsy needle. Image processing techniques analyze volumes to calculate the location of a target lesion. This position was converted into the coordinate system of a three axis robot which moved a needle probe to touch the lesion. The second task is to remove shrapnel from a tissue phantom autonomously. In some emergency situations, shrapnel detection in the body is necessary for quick treatment. Furthermore, small or uneven shrapnel geometry may hinder location by typical ultrasound imaging methods. Vibrations and small displacements can be induced in ferromagnetic shrapnel by a variable electromagnet. We used real time 3D color Doppler to locate this motion for 2 mm long needle fragments and determined the 3D position of the fragment in the scanner coordinates. The rms error of the image guided robot for 5 trials was 1.06 mm for this task which was accomplished in 76 seconds.

  2. Scavenging flow velocity in small two-strokes at high engine speed

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ekenberg, M.; Johansson, B.

    1995-12-31

    2D-LDV-measurements were made on the flow from one transfer channel into the cylinder in a small two-stroke SI engine. The LDV measuring volume was located just outside the transfer port. The engine was a carburetted piston-ported crankcase compression chainsaw engine and it was run with wide open throttle at 9000 RPM. The muffler was removed to enable access into the cylinder. No additional seeding was used; the fuel and/or oil was not entirely vaporized as it entered the cylinder. Very high velocities ({approximately}275 m/s) were detected in the beginning of the scavenging phase. The horizontal velocity was, during the wholemore » scavenging phase, higher than the vertical.« less

  3. Two-Dimensional Photonic Crystals for Sensitive Microscale Chemical and Biochemical Sensing

    PubMed Central

    Miller, Benjamin L.

    2015-01-01

    Photonic crystals – optical devices able to respond to changes in the refractive index of a small volume of space – are an emerging class of label-free chemical-and bio-sensors. This review focuses on one class of photonic crystal, in which light is confined to a patterned planar material layer of sub-wavelength thickness. These devices are small (on the order of tens to 100s of microns square), suitable for incorporation into lab-on-a-chip systems, and in theory can provide exceptional sensitivity. We introduce the defining characteristics and basic operation of two-dimensional photonic crystal sensors, describe variations of their basic design geometry, and summarize reported detection results from chemical and biological sensing experiments. PMID:25563402

  4. Big Cat Coalitions: A Comparative Analysis of Regional Brain Volumes in Felidae.

    PubMed

    Sakai, Sharleen T; Arsznov, Bradley M; Hristova, Ani E; Yoon, Elise J; Lundrigan, Barbara L

    2016-01-01

    Broad-based species comparisons across mammalian orders suggest a number of factors that might influence the evolution of large brains. However, the relationship between these factors and total and regional brain size remains unclear. This study investigated the relationship between relative brain size and regional brain volumes and sociality in 13 felid species in hopes of revealing relationships that are not detected in more inclusive comparative studies. In addition, a more detailed analysis was conducted of four focal species: lions ( Panthera leo ), leopards ( Panthera pardus ), cougars ( Puma concolor ), and cheetahs ( Acinonyx jubatus ). These species differ markedly in sociality and behavioral flexibility, factors hypothesized to contribute to increased relative brain size and/or frontal cortex size. Lions are the only truly social species, living in prides. Although cheetahs are largely solitary, males often form small groups. Both leopards and cougars are solitary. Of the four species, leopards exhibit the most behavioral flexibility, readily adapting to changing circumstances. Regional brain volumes were analyzed using computed tomography. Skulls ( n = 75) were scanned to create three-dimensional virtual endocasts, and regional brain volumes were measured using either sulcal or bony landmarks obtained from the endocasts or skulls. Phylogenetic least squares regression analyses found that sociality does not correspond with larger relative brain size in these species. However, the sociality/solitary variable significantly predicted anterior cerebrum (AC) volume, a region that includes frontal cortex. This latter finding is despite the fact that the two social species in our sample, lions and cheetahs, possess the largest and smallest relative AC volumes, respectively. Additionally, an ANOVA comparing regional brain volumes in four focal species revealed that lions and leopards, while not significantly different from one another, have relatively larger AC volumes than are found in cheetahs or cougars. Further, female lions possess a significantly larger AC volume than conspecific males; female lion values were also larger than those of the other three species (regardless of sex). These results may reflect greater complexity in a female lion's social world, but additional studies are necessary. These data suggest that within family comparisons may reveal variations not easily detected by broad comparative analyses.

  5. Big Cat Coalitions: A Comparative Analysis of Regional Brain Volumes in Felidae

    PubMed Central

    Sakai, Sharleen T.; Arsznov, Bradley M.; Hristova, Ani E.; Yoon, Elise J.; Lundrigan, Barbara L.

    2016-01-01

    Broad-based species comparisons across mammalian orders suggest a number of factors that might influence the evolution of large brains. However, the relationship between these factors and total and regional brain size remains unclear. This study investigated the relationship between relative brain size and regional brain volumes and sociality in 13 felid species in hopes of revealing relationships that are not detected in more inclusive comparative studies. In addition, a more detailed analysis was conducted of four focal species: lions (Panthera leo), leopards (Panthera pardus), cougars (Puma concolor), and cheetahs (Acinonyx jubatus). These species differ markedly in sociality and behavioral flexibility, factors hypothesized to contribute to increased relative brain size and/or frontal cortex size. Lions are the only truly social species, living in prides. Although cheetahs are largely solitary, males often form small groups. Both leopards and cougars are solitary. Of the four species, leopards exhibit the most behavioral flexibility, readily adapting to changing circumstances. Regional brain volumes were analyzed using computed tomography. Skulls (n = 75) were scanned to create three-dimensional virtual endocasts, and regional brain volumes were measured using either sulcal or bony landmarks obtained from the endocasts or skulls. Phylogenetic least squares regression analyses found that sociality does not correspond with larger relative brain size in these species. However, the sociality/solitary variable significantly predicted anterior cerebrum (AC) volume, a region that includes frontal cortex. This latter finding is despite the fact that the two social species in our sample, lions and cheetahs, possess the largest and smallest relative AC volumes, respectively. Additionally, an ANOVA comparing regional brain volumes in four focal species revealed that lions and leopards, while not significantly different from one another, have relatively larger AC volumes than are found in cheetahs or cougars. Further, female lions possess a significantly larger AC volume than conspecific males; female lion values were also larger than those of the other three species (regardless of sex). These results may reflect greater complexity in a female lion’s social world, but additional studies are necessary. These data suggest that within family comparisons may reveal variations not easily detected by broad comparative analyses. PMID:27812324

  6. Novel approach for the refractive index gradient measurement in microliter volumes using fiber-optic technology

    NASA Astrophysics Data System (ADS)

    Synovec, Robert E.; Renn, Curtiss N.

    1991-07-01

    The refractive index gradient (RIG) of hydrodynamically controlled profiles can be universally, yet sensitively, measured by carefully probing the radial RIG passing through a z-configuration flow cell. Fiber optic technology is applied in order to provide a narrow, collimated probe beam (100 micrometers diameter) that is deflected by a RIG and measured by a position sensitive detector. The fiber optic construction allows one to probe very small volumes (1 (mu) L to 3 (mu) L) amenable to microbore liquid chromatography ((mu) LC). The combination of (mu) LC and RIG detection is very useful for the analysis of trace quantities (ng injected amounts) of chemical species that are generally difficult to measure, i.e., species that are not amenable to absorbance detection or related techniques. Furthermore, the RIG detector is compatible with conventional mobile phase gradient and thermal gradient (mu) LC, unlike traditional RI detectors. A description of the RIG detector coupled with (mu) LC for the analysis of complex polymer samples is reported. Also, exploration into using the RIG detector for supercritical fluid chromatography is addressed.

  7. A New Clinical Instrument for The Early Detection of Cataract Using Dynamic Light Scattering and Corneal Topography

    NASA Technical Reports Server (NTRS)

    Ansari, Rafat R.; Datiles, Manuel B., III; King, James F.

    2000-01-01

    A growing cataract can be detected at the molecular level using the technique of dynamic light scattering (DLS). However, the success of this method in clinical use depends upon the precise control of the scattering volume inside a patient's eye and especially during patient's repeat visits. This is important because the scattering volume (cross-over region between the scattered fight and incident light) inside the eye in a high-quality DLS set-up is very small (few microns in dimension). This precise control holds the key for success in the longitudinal studies of cataract and during anti-cataract drug screening. We have circumvented these problems by fabricating a new DLS fiber optic probe with a working distance of 40 mm and by mounting it inside a cone of a corneal analyzer. This analyzer is frequently used in mapping the corneal topography during PRK (photorefractive keratectomy) and LASIK (laser in situ keratomileusis) procedures in shaping of the cornea to correct myopia. This new instrument and some preliminary clinical tests on one of us (RRA) showing the data reproducibility are described.

  8. New clinical instrument for the early detection of cataract using dynamic light scattering and corneal topography

    NASA Astrophysics Data System (ADS)

    Ansari, Rafat R.; Datiles, Manuel B., III; King, James F.

    2000-06-01

    A growing cataract can be detected at the molecular level using the technique of dynamic light scattering (DLS). However, the success of this method in clinical use depends upon the precise control of the scattering volume inside a patient's eye and especially during patient's repeat visits. This is important because the scattering volume (cross-over region between the scattered light and incident light) inside the eye in a high-quality DLS set-up is very small (few microns in dimension). This precise control holds the key for success in the longitudinal studies of cataract and during anti-cataract drug screening. We have circumvented these problems by fabricating a new DLS fiber optic probe with a working distance of 40 mm and by mounting it inside a cone of a corneal analyzer. This analyzer is frequently used in mapping the corneal topography during PRK (photorefractive keratectomy) and LASIK (laser in situ keratomileusis) procedures in shaping of the cornea to correct myopia. This new instrument and some preliminary clinical tests on one of us (RRA) showing the data reproducibility are described.

  9. Multinuclear nanoliter one-dimensional and two-dimensional NMR spectroscopy with a single non-resonant microcoil

    NASA Astrophysics Data System (ADS)

    Fratila, Raluca M.; Gomez, M. Victoria; Sýkora, Stanislav; Velders, Aldrik H.

    2014-01-01

    Nuclear magnetic resonance (NMR) spectroscopy is a powerful analytical technique, but its low sensitivity and highly sophisticated, costly, equipment severely constrain more widespread applications. Here we show that a non-resonant planar transceiver microcoil integrated in a microfluidic chip (detection volume 25 nl) can detect different nuclides in the full broad-band range of Larmor frequencies (at 9.4 T from 61 to 400 MHz). Routine one-dimensional (1D) and two-dimensional (2D), homo- and heteronuclear experiments can be carried out using the broad-band coil set-up. Noteworthy, heteronuclear 2D experiments can be performed in a straightforward manner on virtually any combination of nuclides (from classical 1H-13C to more exotic combinations like 19F-31P) both in coupled and decoupled mode. Importantly, the concept of a non-resonant system provides magnetic field-independent NMR probes; moreover, the small-volume alleviates problems related to field inhomogeneity, making the broad-band coil an attractive option for, for example, portable and table-top NMR systems.

  10. AUTOMATED CELL SEGMENTATION WITH 3D FLUORESCENCE MICROSCOPY IMAGES.

    PubMed

    Kong, Jun; Wang, Fusheng; Teodoro, George; Liang, Yanhui; Zhu, Yangyang; Tucker-Burden, Carol; Brat, Daniel J

    2015-04-01

    A large number of cell-oriented cancer investigations require an effective and reliable cell segmentation method on three dimensional (3D) fluorescence microscopic images for quantitative analysis of cell biological properties. In this paper, we present a fully automated cell segmentation method that can detect cells from 3D fluorescence microscopic images. Enlightened by fluorescence imaging techniques, we regulated the image gradient field by gradient vector flow (GVF) with interpolated and smoothed data volume, and grouped voxels based on gradient modes identified by tracking GVF field. Adaptive thresholding was then applied to voxels associated with the same gradient mode where voxel intensities were enhanced by a multiscale cell filter. We applied the method to a large volume of 3D fluorescence imaging data of human brain tumor cells with (1) small cell false detection and missing rates for individual cells; and (2) trivial over and under segmentation incidences for clustered cells. Additionally, the concordance of cell morphometry structure between automated and manual segmentation was encouraging. These results suggest a promising 3D cell segmentation method applicable to cancer studies.

  11. Fiducial migration following small peripheral lung tumor image-guided CyberKnife stereotactic radiosurgery

    NASA Astrophysics Data System (ADS)

    Strulik, Konrad L.; Cho, Min H.; Collins, Brian T.; Khan, Noureen; Banovac, Filip; Slack, Rebecca; Cleary, Kevin

    2008-03-01

    To track respiratory motion during CyberKnife stereotactic radiosurgery in the lung, several (three to five) cylindrical gold fiducials are implanted near the planned target volume (PTV). Since these fiducials remain in the human body after treatment, we hypothesize that tracking fiducial movement over time may correlate with the tumor response to treatment and pulmonary fibrosis, thereby serving as an indicator of treatment success. In this paper, we investigate fiducial migration in 24 patients through examination of computed tomography (CT) volume images at four time points: pre-treatment, three, six, and twelve month post-treatment. We developed a MATLAB based GUI environment to display the images, identify the fiducials, and compute our performance measure. After we semi-automatically segmented and detected fiducial locations in CT images of the same patient over time, we identified them according to their configuration and introduced a relative performance measure (ACD: average center distance) to detect their migration. We found that the migration tended to result in a movement towards the fiducial center of the radiated tissue area (indicating tumor regression) and may potentially be linked to the patient prognosis.

  12. A Deep Penetration Problem Calculation Using AETIUS:An Easy Modeling Discrete Ordinates Transport Code UsIng Unstructured Tetrahedral Mesh, Shared Memory Parallel

    NASA Astrophysics Data System (ADS)

    KIM, Jong Woon; LEE, Young-Ouk

    2017-09-01

    As computing power gets better and better, computer codes that use a deterministic method seem to be less useful than those using the Monte Carlo method. In addition, users do not like to think about space, angles, and energy discretization for deterministic codes. However, a deterministic method is still powerful in that we can obtain a solution of the flux throughout the problem, particularly as when particles can barely penetrate, such as in a deep penetration problem with small detection volumes. Recently, a new state-of-the-art discrete-ordinates code, ATTILA, was developed and has been widely used in several applications. ATTILA provides the capabilities to solve geometrically complex 3-D transport problems by using an unstructured tetrahedral mesh. Since 2009, we have been developing our own code by benchmarking ATTILA. AETIUS is a discrete ordinates code that uses an unstructured tetrahedral mesh such as ATTILA. For pre- and post- processing, Gmsh is used to generate an unstructured tetrahedral mesh by importing a CAD file (*.step) and visualizing the calculation results of AETIUS. Using a CAD tool, the geometry can be modeled very easily. In this paper, we describe a brief overview of AETIUS and provide numerical results from both AETIUS and a Monte Carlo code, MCNP5, in a deep penetration problem with small detection volumes. The results demonstrate the effectiveness and efficiency of AETIUS for such calculations.

  13. Effects of amyloid and small vessel disease on white matter network disruption.

    PubMed

    Kim, Hee Jin; Im, Kiho; Kwon, Hunki; Lee, Jong Min; Ye, Byoung Seok; Kim, Yeo Jin; Cho, Hanna; Choe, Yearn Seong; Lee, Kyung Han; Kim, Sung Tae; Kim, Jae Seung; Lee, Jae Hong; Na, Duk L; Seo, Sang Won

    2015-01-01

    There is growing evidence that the human brain is a large scale complex network. The structural network is reported to be disrupted in cognitively impaired patients. However, there have been few studies evaluating the effects of amyloid and small vessel disease (SVD) markers, the common causes of cognitive impairment, on structural networks. Thus, we evaluated the association between amyloid and SVD burdens and structural networks using diffusion tensor imaging (DTI). Furthermore, we determined if network parameters predict cognitive impairments. Graph theoretical analysis was applied to DTI data from 232 cognitively impaired patients with varying degrees of amyloid and SVD burdens. All patients underwent Pittsburgh compound-B (PiB) PET to detect amyloid burden, MRI to detect markers of SVD, including the volume of white matter hyperintensities and the number of lacunes, and detailed neuropsychological testing. The whole-brain network was assessed by network parameters of integration (shortest path length, global efficiency) and segregation (clustering coefficient, transitivity, modularity). PiB retention ratio was not associated with any white matter network parameters. Greater white matter hyperintensity volumes or lacunae numbers were significantly associated with decreased network integration (increased shortest path length, decreased global efficiency) and increased network segregation (increased clustering coefficient, increased transitivity, increased modularity). Decreased network integration or increased network segregation were associated with poor performances in attention, language, visuospatial, memory, and frontal-executive functions. Our results suggest that SVD alters white matter network integration and segregation, which further predicts cognitive dysfunction.

  14. Satellite Observations of Antarctic Sea Ice Thickness and Volume

    NASA Technical Reports Server (NTRS)

    Kurtz, Nathan; Markus, Thorsten

    2012-01-01

    We utilize satellite laser altimetry data from ICESat combined with passive microwave measurements to analyze basin-wide changes in Antarctic sea ice thickness and volume over a 5 year period from 2003-2008. Sea ice thickness exhibits a small negative trend while area increases in the summer and fall balanced losses in thickness leading to small overall volume changes. Using a five year time-series, we show that only small ice thickness changes of less than -0.03 m/yr and volume changes of -266 cu km/yr and 160 cu km/yr occurred for the spring and summer periods, respectively. The calculated thickness and volume trends are small compared to the observational time period and interannual variability which masks the determination of long-term trend or cyclical variability in the sea ice cover. These results are in stark contrast to the much greater observed losses in Arctic sea ice volume and illustrate the different hemispheric changes of the polar sea ice covers in recent years.

  15. Experimental determination of the PTW 60019 microDiamond dosimeter active area and volume

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marinelli, Marco, E-mail: marco.marinelli@uniroma2

    Purpose: Small field output correction factors have been studied by several research groups for the PTW 60019 microDiamond (MD) dosimeter, by comparing the response of such a device with both reference dosimeters and Monte Carlo simulations. A general good agreement is observed for field sizes down to about 1 cm. However, evident inconsistencies can be noticed when comparing some experimental results and Monte Carlo simulations obtained for smaller irradiation fields. This issue was tentatively attributed by some authors to unintentional large variations of the MD active surface area. The aim of the present study is a nondestructive experimental determination ofmore » the MD active surface area and active volume. Methods: Ten MD dosimeters, one MD prototype, and three synthetic diamond samples were investigated in the present work. 2D maps of the MD response were recorded under scanned soft x-ray microbeam irradiation, leading to an experimental determination of the device active surface area. Profiles of the device responses were measured as well. In order to evaluate the MD active volume, the thickness of the diamond sensing layer was independently evaluated by capacitance measurements and alpha particle detection experiments. The MD sensitivity, measured at the PTW calibration laboratory, was also used to calculate the device active volume thickness. Results: An average active surface area diameter of (2.19 ± 0.02) mm was evaluated by 2D maps and response profiles of all the MDs. Average active volume thicknesses of (1.01 ± 0.13) μm and (0.97 ± 0.14) μm were derived by capacitance and sensitivity measurements, respectively. The obtained results are well in agreement with the nominal values reported in the manufacturer dosimeter specifications. A homogeneous response was observed over the whole device active area. Besides the one from the device active volume, no contributions from other components of the housing nor from encapsulation materials were observed in the 2D response maps. Conclusions: The obtained results demonstrate the high reproducibility of the MD fabrication process. The observed discrepancies among the output correction factors reported by several authors for MD response in very small fields are very unlikely to be ascribed to unintentional variations of the device active surface area and volume. It is the opinion of the authors that the role of the volume averaging as well as of other perturbation effects should be separately investigated instead, both experimentally and by Monte Carlo simulations, in order to better clarify the behaviour of the MD response in very small fields.« less

  16. Apparatus and method for collection and concentration of respirable particles into a small fluid volume

    DOEpatents

    Simon, Jonathan N.; Brown, Steve B.

    2002-01-01

    An apparatus and method for the collection of respirable particles and concentration of such particles into a small fluid volume. The apparatus captures and concentrates small (1-10 .mu.m) respirable particles into a sub-millileter volume of fluid. The method involves a two step operation, collection and concentration: wherein collection of particles is by a wetted surface having small vertical slits that act as capillary channels; and concentration is carried out by transfer of the collected particles to a small volume (sub-milliliter) container by centrifugal force whereby the particles are forced through the vertical slits and contact a non-wetted wall surface, and are deflected to the bottom where they are contained for analysis, such as a portable flow cytometer or a portable PCR DNA analysis system.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Levine, E.; Cook, L.T.; Grantham, J.J.

    Hepatic CT findings were analyzed in 44 patients with autosomal-dominant polycystic kidney disease and were correlated with liver and renal function tests and liver, splenic, and renal CT volume measurements. CT showed many large liver cysts in 31.8% of patients, small liver cysts in 25%, and no liver cysts in 43.2%. Patients with many large cysts often showed increased liver volumes. There was no correlation between severity of liver involvement and extent of renal cystic disease as determined from urea nitrogen and creatinine levels and renal volumes. Liver function tests were normal except in two patients, one with a cholangiocarcinoma,more » which may have arisen from a cyst, and the other with an infected liver cyst and chronic active hepatitis. Accordingly, if liver function tests are abnormal, an attempt should be made to identify complications of polycystic liver disease such as tumor cyst infection, and biliary obstruction. CT is a useful method for detecting liver cysts and identifying patients at risk for these complications.« less

  18. Interior tomographic imaging for x-ray coherent scattering (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Pang, Sean; Zhu, Zheyuan

    2017-05-01

    Conventional computed tomography reconstructs the attenuation only high-dimensional images. Coherent scatter computed tomography, which reconstructs the angular dependent scattering profiles of 3D objects, can provide molecular signatures that improves the accuracy of material identification and classification. Coherent scatter tomography are traditionally acquired by setups similar to x-ray powder diffraction machine; a collimated source in combination with 2D or 1D detector collimation in order to localize the scattering point. In addition, the coherent scatter cross-section is often 3 orders of magnitude lower than that of the absorption cross-section for the same material. Coded aperture and structured illumination approaches has been shown to greatly improve the collection efficiency. In many applications, especially in security imaging and medical diagnosis, fast and accurate identification of the material composition of a small volume within the whole object would lead to an accelerated imaging procedure and reduced radiation dose. Here, we report an imaging method to reconstruct the material coherent scatter profile within a small volume. The reconstruction along one radial direction can reconstruct a scalar coherent scattering tomographic image. Our methods takes advantage of the finite support of the scattering profile in small angle regime. Our system uses a pencil beam setup without using any detector side collimation. Coherent scatter profile of a 10 mm scattering sample embedded in a 30 mm diameter phantom was reconstructed. The setup has small form factor and is suitable for various portable non-destructive detection applications.

  19. Commercial multicopter unmanned aircraft system as a tool for early stage forest survey after wind damage

    NASA Astrophysics Data System (ADS)

    Mokros, Martin; Vybostok, Jozef; Merganic, Jan; Tomastik, Julian; Cernava, Juraj

    2017-04-01

    In recent years unmanned aircraft systems (UAS) are objects of research in many areas. This trend can be seen also in forest research where researchers are focusing on height, diameter and tree crown measurements, monitoring of forest fire, forest gaps and health condition. Our research is focusing on the use of UAS for detecting areas disturbed by wind and deriving the volume of fallen trees for management purposes. This information is crucial after the wind damage happened. We used DJI Phantom 2 Vision+ and acquired the imagery of one forest stand (5.7 ha). The UAS is a quadcopter "all in one" solution. It has a built-in camera with gimbal and a remote controller. The camera is controlled through the application (android/ios). The built-in camera has an image resolution of 4384×3288 (14 megapixels). We have placed five crosses within the plot to be able to georeference the point cloud from UAS. Their positions were measured by Topcon Hiper GGD survey-grade GNSS receiver. We measured the border of damaged area by four different GNSS devices - GeoExplorer 6000, Trimble Nomad, Garmin GPSMAP 60 CSx and by smartphone Sony Xperia X. To process images from UAS we used Agisoft Photoscan Professional, while ArcGIS 10.2 was used to calculate and compare the areas . From the UAS point cloud we calculated DTM and DSM and deducted them. The areas where the difference was close to zero (-0.2 to 0.2) were signed as potentially wind damage areas. Then we filtered the areas that were not signed correctly (for example routes). The calculated area from UAS was 2.66 ha, GeoExplorer 6000 was 2.20 ha, Nomad was 2.06 ha, Garmin was 2.21 ha and from Xperia was the area 2.24 ha. The differences between UAS and GPS devices vary from 0.42 ha to 0.6 ha. The differences were mostly caused by inability to detect small spots of fallen trees on UAS data. These small spots are difficult to measure by GPS devices because the signal is very poor under tree crowns and also it is difficult to find such small spots within the area. Based on the derived area and per hectare volume of the most common tree specie from forest plan (Fagus sylvatica 83%) we calculated the volume of damaged trees and compared the result with data from forest district. The forest district harvested all damaged trees and measured their volume. The volume derived from UAS and forest plan data was 918 m3 and volume measured by forest district was 775 m3. The difference was 143 m3 (18%). The next step of our research is to verify the use of fixed wing UAS for larger areas.

  20. Reusable and Mediator-Free Cholesterol Biosensor Based on Cholesterol Oxidase Immobilized onto TGA-SAM Modified Smart Bio-Chips

    PubMed Central

    Rahman, Mohammed M.

    2014-01-01

    A reusable and mediator-free cholesterol biosensor based on cholesterol oxidase (ChOx) was fabricated based on self-assembled monolayer (SAM) of thioglycolic acid (TGA) (covalent enzyme immobilization by dropping method) using bio-chips. Cholesterol was detected with modified bio-chip (Gold/Thioglycolic-acid/Cholesterol-oxidase i.e., Au/TGA/ChOx) by reliable cyclic voltammetric (CV) technique at room conditions. The Au/TGA/ChOx modified bio-chip sensor demonstrates good linearity (1.0 nM to 1.0 mM; R = 0.9935), low-detection limit (∼0.42 nM, SNR∼3), and higher sensitivity (∼74.3 µAµM−1cm−2), lowest-small sample volume (50.0 μL), good stability, and reproducibility. To the best of our knowledge, this is the first statement with a very high sensitivity, low-detection limit, and low-sample volumes are required for cholesterol biosensor using Au/TGA/ChOx-chips assembly. The result of this facile approach was investigated for the biomedical applications for real samples at room conditions with significant assembly (Au/TGA/ChOx) towards the development of selected cholesterol biosensors, which can offer analytical access to a large group of enzymes for wide range of biomedical applications in health-care fields. PMID:24949733

  1. Method for measurement of radon diffusion and solubility in solid materials

    NASA Astrophysics Data System (ADS)

    Maier, Andreas; Weber, Uli; Dickmann, Jannis; Breckow, Joachim; van Beek, Patrick; Schardt, Dieter; Kraft, Gerhard; Fournier, Claudia

    2018-02-01

    In order to study the permeation i.e. the diffusion and solubility of radon gas in biological material, a new setup was constructed and a novel analysis was applied to obtain diffusion and solubility coefficients. Thin slabs of solid materials were installed between detector housing and the surrounding radon exposure chamber of 50 Ls volume. In this setup radon can diffuse through thin test samples into a cylindrical volume of 5 mm height and 20 mm diameter and reach an α-particle detector. There the 5.49 MeV α-decay of the penetrating radon atoms is measured by a silicon surface barrier detector. The time dependent activities inside the small detector volume are recorded after injection of a known radon activity concentration into the outer chamber. Analyzing the time behavior of the integral α-activity from radon in the small vessel, both, the diffusion coefficient and solubility of the test material can be determined, based on a new mathematical model of the diffusion process concerning the special boundary conditions given by the experimental setup. These first measurements were intended as proof of concept for the detection system and the data analysis. Thin polyethylene foils (LDPE) were selected as material for the diffusion measurements and the results were in agreement with data from literature. In further measurements, we will concentrate on biological material like bone, fat and other tissues.

  2. Microsystem strategies for sample preparation in biological detection.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    James, Conrad D.; Galambos, Paul C.; Bennett, Dawn Jonita

    2005-03-01

    The objective of this LDRD was to develop microdevice strategies for dealing with samples to be examined in biological detection systems. This includes three sub-components: namely, microdevice fabrication, sample delivery to the microdevice, and sample processing within the microdevice. The first component of this work focused on utilizing Sandia's surface micromachining technology to fabricate small volume (nanoliter) fluidic systems for processing small quantities of biological samples. The next component was to develop interfaces for the surface-micromachined silicon devices. We partnered with Micronics, a commercial company, to produce fluidic manifolds for sample delivery to our silicon devices. Pressure testing was completedmore » to examine the strength of the bond between the pressure-sensitive adhesive layer and the silicon chip. We are also pursuing several other methods, both in house and external, to develop polymer-based fluidic manifolds for packaging silicon-based microfluidic devices. The second component, sample processing, is divided into two sub-tasks: cell collection and cell lysis. Cell collection was achieved using dielectrophoresis, which employs AC fields to collect cells at energized microelectrodes, while rejecting non-cellular particles. Both live and dead Staph. aureus bacteria have been collected using RF frequency dielectrophoresis. Bacteria have been separated from polystyrene microspheres using frequency-shifting dielectrophoresis. Computational modeling was performed to optimize device separation performance, and to predict particle response to the dielectrophoretic traps. Cell lysis is continuing to be pursued using microactuators to mechanically disrupt cell membranes. Novel thermal actuators, which can generate larger forces than previously tested electrostatic actuators, have been incorporated with and tested with cell lysis devices. Significant cell membrane distortion has been observed, but more experiments need to be conducted to determine the effects of the observed distortion on membrane integrity and cell viability. Finally, we are using a commercial PCR DNA amplification system to determine the limits of detectable sample size, and to examine the amplification of DNA bound to microspheres. Our objective is to use microspheres as capture-and-carry chaperones for small molecules such as DNA and proteins, enabling the capture and concentration of the small molecules using dielectrophoresis. Current tests demonstrated amplification of DNA bound to micron-sized polystyrene microspheres using 20-50 microliter volume size reactions.« less

  3. Parsing partial molar volumes of small molecules: a molecular dynamics study.

    PubMed

    Patel, Nisha; Dubins, David N; Pomès, Régis; Chalikian, Tigran V

    2011-04-28

    We used molecular dynamics (MD) simulations in conjunction with the Kirkwood-Buff theory to compute the partial molar volumes for a number of small solutes of various chemical natures. We repeated our computations using modified pair potentials, first, in the absence of the Coulombic term and, second, in the absence of the Coulombic and the attractive Lennard-Jones terms. Comparison of our results with experimental data and the volumetric results of Monte Carlo simulation with hard sphere potentials and scaled particle theory-based computations led us to conclude that, for small solutes, the partial molar volume computed with the Lennard-Jones potential in the absence of the Coulombic term nearly coincides with the cavity volume. On the other hand, MD simulations carried out with the pair interaction potentials containing only the repulsive Lennard-Jones term produce unrealistically large partial molar volumes of solutes that are close to their excluded volumes. Our simulation results are in good agreement with the reported schemes for parsing partial molar volume data on small solutes. In particular, our determined interaction volumes() and the thickness of the thermal volume for individual compounds are in good agreement with empirical estimates. This work is the first computational study that supports and lends credence to the practical algorithms of parsing partial molar volume data that are currently in use for molecular interpretations of volumetric data.

  4. Detection methods for human enteric viruses in representative foods.

    PubMed

    Leggitt, P R; Jaykus, L A

    2000-12-01

    Although viral foodborne disease is a significant problem, foods are rarely tested for viral contamination, and when done, testing is limited to shellfish commodities. In this work, we report a method to extract and detect human enteric viruses from alternative food commodities using an elution-concentration approach followed by detection using reverse transcription-polymerase chain reaction (RT-PCR). Fifty-gram lettuce or hamburger samples were artificially inoculated with poliovirus type 1 (PV1), hepatitis A virus (HAV), or the Norwalk virus and processed by the sequential steps of homogenization, filtration, Freon extraction (hamburger), and polyethylene glycol (PEG) precipitation. To reduce volumes further and remove RT-PCR inhibitors, a secondary PEG precipitation was necessary, resulting in an overall 10- to 20-fold sample size reduction from 50 g to 3 to 5 ml. Virus recoveries in secondary PEG concentrates ranged from 10 to 70% for PV1 and 2 to 4% for HAV as evaluated by mammalian cell culture infectivity assay. Total RNA from PEG concentrates was extracted to a small volume (30 to 40 microl) and subjected to RT-PCR amplification of viral RNA sequences. Detection limit studies indicated that viral RNA was consistently detected by RT-PCR at initial inoculum levels > or =102 PFU/50-g food sample for PV1 and > or =10(3) PFU/50-g food sample for HAV. In similar studies with the Norwalk virus, detection at inoculum levels > or =1.5 X 10(3) PCR-amplifiable units/50-g sample for both food products was possible. All RT-PCR amplicons were confirmed by subsequent Southern hybridization. The procedure reported represents progress toward the development of methods to detect human enteric viral contamination in foods other than shellfish.

  5. Comparison between Hydrogen, Methane and Ethylene Fuels in a 3-D Scramjet at Mach 8

    DTIC Science & Technology

    2016-06-24

    characteristics in air. The disadvantage of hydrogen is its low density, which is a particular problem for small vehicles with significant internal...characteristics in air. The disadvantage of hydrogen is its low density, which is a particular problem for small vehicles with significant internal volume...The low energy per unit volume of gaseous hydrogen, however, is a significant problem for small vehicles with internal volume constraints, in addition

  6. Brain tissue volumes in the general elderly population. The Rotterdam Scan Study.

    PubMed

    Ikram, M Arfan; Vrooman, Henri A; Vernooij, Meike W; van der Lijn, Fedde; Hofman, Albert; van der Lugt, Aad; Niessen, Wiro J; Breteler, Monique M B

    2008-06-01

    We investigated how volumes of cerebrospinal fluid (CSF), grey matter (GM) and white matter (WM) varied with age, sex, small vessel disease and cardiovascular risk factors in the Rotterdam Scan Study. Participants (n=490; 60-90 years) were non-demented and 51.0% had hypertension, 4.9% had diabetes mellitus, 17.8% were current smoker and 54.0% were former smoker. We segmented brain MR-images into GM, normal WM, white matter lesion (WML) and CSF. Brain infarcts were rated visually. Volumes were expressed as percentage of intra-cranial volume. With increasing age, volumes of total brain, normal WM and total WM decreased; that of GM remained unchanged; and that of WML increased, in both men and women. Excluding persons with infarcts did not alter these results. Persons with larger load of small vessel disease had smaller brain volume, especially normal WM volume. Diastolic blood pressure, diabetes mellitus and current smoking were also related to smaller brain volume. In the elderly, higher age, small vessel disease and cardiovascular risk factors are associated with smaller brain volume, especially WM volume.

  7. Matched filter based detection of floating mines in IR spacetime

    NASA Astrophysics Data System (ADS)

    Borghgraef, Alexander; Lapierre, Fabian; Philips, Wilfried; Acheroy, Marc

    2009-09-01

    Ship-based automatic detection of small floating objects on an agitated sea surface remains a hard problem. Our main concern is the detection of floating mines, which proved a real threat to shipping in confined waterways during the first Gulf War, but applications include salvaging,search-and-rescue and perimeter or harbour defense. IR video was chosen for its day-and-night imaging capability, and its availability on military vessels. Detection is difficult because a rough sea is seen as a dynamic background of moving objects with size order, shape and temperature similar to those of the floating mine. We do find a determinant characteristic in the target's periodic motion, which differs from that of the propagating surface waves composing the background. The classical detection and tracking approaches give bad results when applied to this problem. While background detection algorithms assume a quasi-static background, the sea surface is actually very dynamic, causing this category of algorithms to fail. Kalman or particle filter algorithms on the other hand, which stress temporal coherence, suffer from tracking loss due to occlusions and the great noise level of the image. We propose an innovative approach. This approach uses the periodicity of the objects movement and thus its temporal coherence. The principle is to consider the video data as a spacetime volume similar to a hyperspectral data cube by replacing the spectral axis with a temporal axis. We can then apply algorithms developed for hyperspectral detection problems to the detection of small floating objects. We treat the detection problem using multilinear algebra, designing a number of finite impulse response filters (FIR) maximizing the target response. The algorithm was applied to test footage of practice mines in the infrared.

  8. Seismicity patterns during a period of inflation at Sierra Negra volcano, Galápagos Ocean Island Chain

    NASA Astrophysics Data System (ADS)

    Davidge, Lindsey; Ebinger, Cynthia; Ruiz, Mario; Tepp, Gabrielle; Amelung, Falk; Geist, Dennis; Coté, Dustin; Anzieta, Juan

    2017-03-01

    Basaltic shield volcanoes of the western Galápagos islands are among the most rapidly deforming volcanoes worldwide, but little was known of the internal structure and brittle deformation processes accompanying inflation and deflation cycles. A 15-station broadband seismic array was deployed on and surrounding Sierra Negra volcano, Galápagos from July 2009 through June 2011 to characterize seismic strain patterns during an inter-eruption inflation period and to evaluate single and layered magma chamber models for ocean island volcanoes. We compare precise earthquake locations determined from a 3D velocity model and from a double difference cluster method. Using first-motion of P-arrivals, we determine focal mechanisms for 8 of the largest earthquakes (ML ≤ 1.5) located within the array. Most of the 2382 earthquakes detected by the array occurred beneath the broad (∼9 km-wide) Sierra Negra caldera, at depths from surface to about 8 km below sea level. Although outside our array, frequent and larger magnitude (ML ≤ 3.4) earthquakes occurred at Alcedo and Fernandina volcano, and in a spatial cluster beneath the shallow marine platform between Fernandina and Sierra Negra volcanoes. The time-space relations and focal mechanism solutions from a 4-day long period of intense seismicity June 4-9, 2010 along the southeastern flank of Sierra Negra suggests that the upward-migrating earthquake swarm occurred during a small volume intrusion at depths 5-8 km subsurface, but there was no detectable signal in InSAR data to further constrain geometry and volume. Focal mechanisms of earthquakes beneath the steep intra-caldera faults and along the ring fault system are reverse and strike-slip. These new seismicity data integrated with tomographic, geodetic, and petrological models indicate a stratified magmatic plumbing system: a shallow sill beneath the large caldera that is supplied by magma from a large volume deeper feeding system. The large amplitude inter-eruption inflation of the shallow sill beneath the Sierra Negra caldera is accompanied by only very small magnitude earthquakes, although historical records indicate that larger magnitude earthquakes (Mw <6) occur during eruptions, trapdoor faulting episodes without eruptions, and large volume flank intrusions.

  9. Development test results of the Portable, Reconfigurable Sky Sensor (PRSS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blattman, D.A.

    1993-12-31

    The protection of assets against surreptitious access from the sky is a continuing problem. The Portable, Reconfigurable Sky Sensor is designed to provide volumetric intruder detection against low-observable aircraft, helicopters, and parachutists in the sky. Multiple systems may be joined to form continuous detection volume for applications such as borders. The PRSS is resistant to nuisance alarms due to wind up to 70 mph, rain/snow up to 6 inches/hour or small targets such as birds. The PRSS has been successfully tested against multiple intrusions with altitude range from 50 to 3,000 feet and cross-range up to 3,000 feet. This papermore » summarizes some of these field tests and lists specifications and potential uses.« less

  10. Positional calibration of an ultrasound image-guided robotic breast biopsy system.

    PubMed

    Nelson, Thomas R; Tran, Amy; Fakourfar, Hourieh; Nebeker, Jakob

    2012-03-01

    Precision biopsy of small lesions is essential in providing high-quality patient diagnosis and management. Localization depends on high-quality imaging. We have developed a dedicated, fully automatic volume breast ultrasound (US) imaging system for early breast cancer detection. This work focuses on development of an image-guided robotic biopsy system that is integrated with the volume breast US system for performing minimally invasive breast biopsies. The objective of this work was to assess the positional accuracy of the robotic system for breast biopsy. We have adapted a compact robotic arm for performing breast biopsy. The arm incorporates a force torque sensor and is modified to accommodate breast biopsy sampling needles mounted on the robot end effector. Volume breast US images are used as input to a targeting algorithm that provides the physician with control of biopsy device guidance and trajectory optimization. In this work, the positional accuracy was evaluated using (1) a light-emitting diode (LED) mounted on the end effector and (2) a LED mounted on the end of a biopsy needle, each of which was imaged for each robot controller position as part of mapping the positional accuracy throughout a volume that would contain the breast. We measured the error in each location and the cumulative error. Robotic device performance over the volume provided mean accuracy ± SD of 0.76 ± 0.13 mm (end effector) and 0.55 ± 0.13 mm (needle sample location), sufficient for a targeting accuracy within ±1 mm, which is suitable for clinical use. Depth positioning error also was small: 0.38 ± 0.03 mm. Reproducibility was excellent with less than 0.5% variation. Overall accuracy and reproducibility of the compact robotic device were excellent, well within clinical biopsy performance requirements. Volume breast US data provide high-quality input to a biopsy sampling algorithm under physician control. Robotic devices may provide more precise device placement, assisting physicians with biopsy procedures.

  11. Small Power Systems Solar Electric Workshop Proceedings. Volume 1: Executive report. Volume 2: Invited papers

    NASA Technical Reports Server (NTRS)

    Ferber, R. (Editor); Evans, D. (Editor)

    1978-01-01

    The background, objectives and methodology used for the Small Power Systems Solar Electric Workshop are described, and a summary of the results and conclusions developed at the workshop regarding small solar thermal electric power systems is presented.

  12. Desalting by crystallization: detection of attomole biomolecules in picoliter buffers by mass spectrometry.

    PubMed

    Gong, Xiaoyun; Xiong, Xingchuang; Wang, Song; Li, Yanyan; Zhang, Sichun; Fang, Xiang; Zhang, Xinrong

    2015-10-06

    Sensitive detection of biomolecules in small-volume samples by mass spectrometry is, in many cases, challenging because of the use of buffers to maintain the biological activities of proteins and cells. Here, we report a highly effective desalting method for picoliter samples. It was based on the spontaneous separation of biomolecules from salts during crystallization of the salts. After desalting, the biomolecules were deposited in the tip of the quartz pipet because of the evaporation of the solvent. Subsequent detection of the separated biomolecules was achieved using solvent assisted electric field induced desorption/ionization (SAEFIDI) coupled with mass spectrometry. It allowed for direct desorption/ionization of the biomolecules in situ from the tip of the pipet. The organic component in the assistant solvent inhibited the desorption/ionization of salts, thus assured successful detection of biomolecules. Proteins and peptides down to 50 amol were successfully detected using our method even if there were 3 × 10(5) folds more amount of salts in the sample. The concentration and ion species of the salts had little influence on the detection results.

  13. Small Autonomous Aircraft Servo Health Monitoring

    NASA Technical Reports Server (NTRS)

    Quintero, Steven

    2008-01-01

    Small air vehicles offer challenging power, weight, and volume constraints when considering implementation of system health monitoring technologies. In order to develop a testbed for monitoring the health and integrity of control surface servos and linkages, the Autonomous Aircraft Servo Health Monitoring system has been designed for small Uninhabited Aerial Vehicle (UAV) platforms to detect problematic behavior from servos and the air craft structures they control, This system will serve to verify the structural integrity of an aircraft's servos and linkages and thereby, through early detection of a problematic situation, minimize the chances of an aircraft accident. Embry-Riddle Aeronautical University's rotary-winged UAV has an Airborne Power management unit that is responsible for regulating, distributing, and monitoring the power supplied to the UAV's avionics. The current sensing technology utilized by the Airborne Power Management system is also the basis for the Servo Health system. The Servo Health system measures the current draw of the servos while the servos are in Motion in order to quantify the servo health. During a preflight check, deviations from a known baseline behavior can be logged and their causes found upon closer inspection of the aircraft. The erratic behavior nay include binding as a result of dirt buildup or backlash caused by looseness in the mechanical linkages. Moreover, the Servo Health system will allow elusive problems to be identified and preventative measures taken to avoid unnecessary hazardous conditions in small autonomous aircraft.

  14. Deviation from Power Law Behavior in Landslide Phenomenon

    NASA Astrophysics Data System (ADS)

    Li, L.; Lan, H.; Wu, Y.

    2013-12-01

    Power law distribution of magnitude is widely observed in many natural hazards (e.g., earthquake, floods, tornadoes, and forest fires). Landslide is unique as the size distribution of landslide is characterized by a power law decrease with a rollover in the small size end. Yet, the emergence of the rollover, i.e., the deviation from power law behavior for small size landslides, remains a mystery. In this contribution, we grouped the forces applied on landslide bodies into two categories: 1) the forces proportional to the volume of failure mass (gravity and friction), and 2) the forces proportional to the area of failure surface (cohesion). Failure occurs when the forces proportional to volume exceed the forces proportional to surface area. As such, given a certain mechanical configuration, the failure volume to failure surface area ratio must exceed a corresponding threshold to guarantee a failure. Assuming all landslides share a uniform shape, which means the volume to surface area ratio of landslide regularly increase with the landslide volume, a cutoff of landslide volume distribution in the small size end can be defined. However, in realistic landslide phenomena, where heterogeneities of landslide shape and mechanical configuration are existent, a simple cutoff of landslide volume distribution does not exist. The stochasticity of landslide shape introduce a probability distribution of the volume to surface area ratio with regard to landslide volume, with which the probability that the volume to surface ratio exceed the threshold can be estimated regarding values of landslide volume. An experiment based on empirical data showed that this probability can induce the power law distribution of landslide volume roll down in the small size end. We therefore proposed that the constraints on the failure volume to failure surface area ratio together with the heterogeneity of landslide geometry and mechanical configuration attribute for the deviation from power law behavior in landslide phenomenon. Figure shows that a rollover of landslide size distribution in the small size end is produced as the probability for V/S (the failure volume to failure surface ratio of landslide) exceeding the mechanical threshold applied to the power law distribution of landslide volume.

  15. 40 CFR 80.595 - How does a small or GPA refiner apply for a motor vehicle diesel fuel volume baseline for the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... for a motor vehicle diesel fuel volume baseline for the purpose of extending their gasoline sulfur... a small or GPA refiner apply for a motor vehicle diesel fuel volume baseline for the purpose of... duration of the GPA standards under § 80.540 must apply for a motor vehicle diesel fuel volume baseline by...

  16. Defense Small Business Innovation Research Program (SBIR). Volume 4. Defense Agency Projects, Abstracts of Phase 1 Awards from FY 1989 SBIR Solicitation

    DTIC Science & Technology

    1990-04-01

    EXPLOSIVE ACTIVITY . FINDINGS AND MEASUREMENTS FROM EACH IMAGE WILL BE COMBINED IN A GEOGRAPHIC INFORMATION DATA BASE . VARIOUS IMAGE AND MAP PROJECTS WILL BE...PROPOSAL OF LAND MINES DETECTION BY A NUCLEAR ACTIVATION METHOD IS BASED ON A NEW EXTREMELY INTENSE, COMPACT PULSED SOURCE OF 14.1 MeV NEUTRONS (WITH A...CONVENTIONAL KNOWLEDGE- BASED SYSTEMS TOPIC# 38 OFFICE: PM/SBIR IDENT#: 33862 CASE- BASED REASONING (CBR) REPRESENTS A POWERFUL NEW PARADIGM FOR BUILDING EXPERT

  17. Liquid chromatographic determination of florfenicol in the plasma of multiple species of fish

    USGS Publications Warehouse

    Vue, C.; Schmidt, L.J.; Stehly, G.R.; Gingerich, W.H.

    2002-01-01

    A simple method was developed for determining florfenicol concentration in a small volume (250 mul) of plasma from five phylogenetically diverse species of freshwater fish. Florfenicol was isolated from the plasma matrix through C-18 solid-phase extraction and quantified by reversed-phase high-performance liquid chromatography with UV detection. The accuracy (84-104%), precision (%RSDless than or equal to8), and sensitivity (quantitation limit <30 ng/ml) of the method indicate its usefulness for conducting pharmacokinetic studies on a variety of freshwater fish. Published by Elsevier Science B.V.

  18. Locked Nucleic Acid Flow Cytometry-fluorescence in situ Hybridization (LNA flow-FISH): A Method for Bacterial Small RNA Detection

    DTIC Science & Technology

    2012-01-10

    flow cytometry, locked nucleic acid, sRNA, Vibrio , Date Published: 1/10/2012 This is an open-access article distributed under the terms of the Creative...solubilization process to maintain a 10 mL volume. Aliquot the 60% dextran sulfate solution and store at -20 °C until use. 1. Harvest 1x108 cells of...bioluminescent Vibrio campbellii or your bacteria of interest and transfer them into a 1.5 mL microcentrifuge tube. This quantity of cells provides

  19. Sensitive liquid refractive index sensors using tapered optical fiber tips.

    PubMed

    Tai, Yi-Hsin; Wei, Pei-Kuen

    2010-04-01

    An optical fiber sensor based on the change of optical confinement in a subwavelength tip is presented. The optical spot is substantially increased when the environmental refractive index (RI) increases from 1.3 to 1.4. By measuring the intensity of low angular spectral components, an intensity sensitivity up to 8000% per RI unit is achieved. The fiber tip sensors take advantage of the small detection volume and real-time responses. We demonstrate the application of the nanofiber sensors for measuring concentrations of acids and evaporation rates of aqueous mixtures.

  20. A pH sensing system using fluorescence-based fibre optical sensor capable of small volume sample measurement

    NASA Astrophysics Data System (ADS)

    Deng, Shijie; McAuliffe, Michael A. P.; Salaj-Kosla, Urszula; Wolfe, Raymond; Lewis, Liam; Huyet, Guillaume

    2017-02-01

    In this work, a low cost optical pH sensing system that allows for small volume sample measurements was developed. The system operates without the requirement of laboratory instruments (e.g. laser source, spectrometer and CCD camera), this lowers the cost and enhances the portability. In the system, an optical arrangement employing a dichroic filter was used which allows the excitation and emission light to be transmitted using a single fibre thus improving the collection efficiency of the fluorescence signal and also the ability of inserting measurement. The pH sensor in the system uses bromocresol purple as the indicator which is immobilised by sol-gel technology through a dip-coating process. The sensor material was coated on the tip of a 1 mm diameter optical fibre which makes it possible for inserting into very small volume samples to measure the pH. In the system, a LED with a peak emission wavelength of 465 nm is used as the light source and a silicon photo-detector is used to detect the uorescence signal. Optical filters are applied after the LED and in front of the photo-detector to separate the excitation and emission light. The fluorescence signal collected is transferred to a PC through a DAQ and processed by a Labview-based graphic-user-interface (GUI). Experimental results show that the system is capable of sensing pH values from 5.3 to 8.7 with a linear response of R2=0.969. Results also show that the response times for a pH changes from 5.3 to 8.7 is approximately 150 s and for a 0.5 pH changes is approximately 50 s.

  1. Whole-breast irradiation: a subgroup analysis of criteria to stratify for prone position treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramella, Sara, E-mail: s.ramella@unicampus.it; Trodella, Lucio; Ippolito, Edy

    2012-07-01

    To select among breast cancer patients and according to breast volume size those who may benefit from 3D conformal radiotherapy after conservative surgery applied with prone-position technique. Thirty-eight patients with early-stage breast cancer were grouped according to the target volume (TV) measured in the supine position: small ({<=}400 mL), medium (400-700 mL), and large ({>=}700 ml). An ad-hoc designed and built device was used for prone set-up to displace the contralateral breast away from the tangential field borders. All patients underwent treatment planning computed tomography in both the supine and prone positions. Dosimetric data to explore dose distribution and volumemore » of normal tissue irradiated were calculated for each patient in both positions. Homogeneity index, hot spot areas, the maximum dose, and the lung constraints were significantly reduced in the prone position (p < 0.05). The maximum heart distance and the V{sub 5Gy} did not vary consistently in the 2 positions (p = 0.06 and p = 0.7, respectively). The number of necessary monitor units was significantly higher in the supine position (312 vs. 232, p < 0.0001). The subgroups analysis pointed out the advantage in lung sparing in all TV groups (small, medium and large) for all the evaluated dosimetric constraints (central lung distance, maximum lung distance, and V{sub 5Gy}, p < 0.0001). In the small TV group, a dose reduction in nontarget areas of 22% in the prone position was detected (p = 0.056); in the medium and high TV groups, the difference was of about -10% (p = NS). The decrease in hot spot areas in nontarget tissues was 73%, 47%, and 80% for small, medium, and large TVs in the prone position, respectively. Although prone breast radiotherapy is normally proposed in patients with breasts of large dimensions, this study gives evidence of dosimetric benefit in all patient subgroups irrespective of breast volume size.« less

  2. A novel wearable device for continuous, non-invasion blood pressure measurement.

    PubMed

    Xin, Qin; Wu, Jianping

    2017-08-01

    In this paper, we have developed a wearable cuffless device for daily blood pressure (BP) measurement. We incorporated the light based sensor and other hard wares in a small volume for BP detection. With optimized algorithm, the real-time BP reading could be achieved, the data could be presented in the screen and be transmitted by internet of things (IoT) for history data comparison and multi-terminal viewing. Thus, further analysis provides the probability for diet or sports suggestion and alarm. We have measured BP from more than 60 subjects, compare to traditional mercury blood pressure meter, no obvious error in both systolic blood pressure (SBP) and diastolic blood pressure (DBP) are detected. Such device can be used for continues non-invasion BP detection, and further data docking and health analysis could be achieved. Copyright © 2017. Published by Elsevier Ltd.

  3. Procedure for detecting and confirming pentobarbital residues in dog food by gas chromatography/mass spectrometry.

    PubMed

    Adam, L A; Reeves, V B

    1998-01-01

    The method described detects and confirms presence of pentobarbital residues in dry, extruded feeds at concentrations of 5-20 ppb. Dried feed is ground to a uniform powder and shaken overnight in methanol. A portion of the methanolic extract is evaporated, and the residue is reconstituted in phosphate-buffered saline. The aqueous extract is cleaned with a solid-phase extraction cartridge designed to extract barbiturate residues from biological matrixes. Dimethyl sulfoxide, tetramethylammonium hydroxide, and iodomethane are added to derivatize pentobarbital, 1,3-Dimethyl-pentobarbital is then acidified with dilute hydrochloric acid and extracted with isooctane. The organic layer is transferred and evaporated under a stream of nitrogen. The residue is reconstituted in a small volume of ethyl acetate for analysis by gas chromatography/mass spectrometry. The limit of detection is approximately 0.7 ppb. The method was validated with pentobarbital-fortified feed samples containing high concentrations of meat and bone meal.

  4. Solar System Exploration Division Strategic Plan, volume 1. Executive summary and overview

    NASA Technical Reports Server (NTRS)

    1991-01-01

    This first document is the first of a six-volume series presenting the Solar System Exploration Division's Strategic Plan for the 10-year period FY 1994 to FY 2003. The overall strategy is characterized by five fundamental precepts: (1) execute the current program; (2) improve the vitality of the program and the planetary science community; (3) initiate innovative, small, low-cost planetary missions; (4) initiate new major and moderate missions; and (5) prepare for the next generation of missions. This Strategic Plan describes in detail our proposed approach to accomplish these goals. Volume 1 provides first an Executive Summary of highlights of each of the six volumes, and then goes on to present an overview of the plan, including a discussion of the planning context and strategic approach. Volumes 2, 3, 4, and 5 describe in detail the initiatives proposed. An integral part of each of these volumes is a set of responses to the mission selection criteria questions developed by the Space and Earth Science Advisory Committee. Volume 2, Mission From Planet Earth, describes a strategy for exploring the Moon and Mars and sets forth proposed moderate missions--Lunar Observer and a Mars lander network. Volume 3, Pluto Flyby/Neptune Orbiter, discusses our proposed major new start candidate for the FY 1994 to FY 1998 time frame. Volume 4, Discovery, describes the Near-Earth Asteroid Rendezvous, as well as other candidates for this program of low-cost planetary missions. Volume 5, Toward Other Planetary Systems, describes a major research and analysis augmentation that focuses on extrasolar planet detection and the study of planetary system processes. Finally, Volume 6 summarizes the technology program that the division has structured around these four initiatives.

  5. Immunocytometric quantitation of foeto-maternal haemorrhage with the Abbott Cell-Dyn CD4000 haematology analyser.

    PubMed

    Little, B H; Robson, R; Roemer, B; Scott, C S

    2005-02-01

    This study evaluated the extended use of a haematology analyser (Abbott Cell-Dyn CD4000) for the immunofluorescent enumeration of foeto-maternal haemorrhage (FMH) with fluorescein isothiocyanate-labelled monoclonal anti-RhD. Method performance was assessed with artificial FMH standards, and a series of 44 clinical samples. Within run precision was <15% (coefficient of variation, CV) for FMH volumes of 3 ml and above, 18.8% at an FMH volume of 2 ml and 31.7% at an FMH volume of 1 ml. Linearity analysis showed excellent agreement (observed FMH% = 0.98x expected FMH% + 0.02), and a close relationship (R(2) = 0.99) between observed and expected FMH percentages. The lower limit of quantification of the CD4000 (SRP-Ret) method with a maximum CV of 15% was 1.6 ml, and the limit of detection was <1 ml. Parallel Kleihauer-Betke test (KBT) assessments of FMH standards showed an overall trend for higher KBT values (observed = 1.25x expected - 0.38). At an FMH level of 4 ml, KBT observer estimates ranged from 0.57 to 11.94 ml with a mean inter-observer CV of 63%. For 44 clinical samples, there was decision point agreement between KBT and SRP-Ret results for 42 samples with an FMH of <2 ml. Analysis in the low FMH range (<1 ml) showed that small volume foetal leaks could be detected with the SRP-Ret method in most of 23 samples with negative KBT results. CD4000 SRP-Ret method performance for FMH determination was similar to that reported for flow cytometry.

  6. Impact of Use of Smaller Volume, Smaller Vacuum Blood Collection Tubes on Hemolysis in Emergency Department Blood Samples.

    PubMed

    Phelan, Michael P; Reineks, Edmunds Z; Berriochoa, Jacob P; Schold, Jesse D; Hustey, Fredric M; Chamberlin, Janelle; Kovach, Annmarie

    2017-10-01

    Hemolyzed blood samples commonly occur in hospital emergency departments (EDs). Our objective was to determine whether replacing standard large-volume/high-vacuum sample tubes with low-volume/low-vacuum tubes would significantly affect ED hemolysis. This was a prospective intervention of the use of small-volume/vacuum collection tubes. We evaluated all potassium samples in ED patients and associated hemolysis. We used χ2 tests to compare hemolysis incidence prior to and following utilization of small tubes for chemistry collection. There were 35,481 blood samples collected during the study period. Following implementation of small-volume tubes, overall hemolysis decreased from a baseline of 11.8% to 2.9% (P < .001) with corresponding reductions in hemolysis with comment (8.95% vs 1.99%; P < .001) gross hemolysis (2.84% vs 0.90%; P < .007). This work demonstrates that significant improvements in ED hemolysis can be achieved by utilization of small-volume/vacuum sample collection tubes. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  7. Small Bowel Dose Parameters Predicting Grade ≥3 Acute Toxicity in Rectal Cancer Patients Treated With Neoadjuvant Chemoradiation: An Independent Validation Study Comparing Peritoneal Space Versus Small Bowel Loop Contouring Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Banerjee, Robyn, E-mail: robynbanerjee@gmail.com; Chakraborty, Santam; Nygren, Ian

    Purpose: To determine whether volumes based on contours of the peritoneal space can be used instead of individual small bowel loops to predict for grade ≥3 acute small bowel toxicity in patients with rectal cancer treated with neoadjuvant chemoradiation therapy. Methods and Materials: A standardized contouring method was developed for the peritoneal space and retrospectively applied to the radiation treatment plans of 67 patients treated with neoadjuvant chemoradiation therapy for rectal cancer. Dose-volume histogram (DVH) data were extracted and analyzed against patient toxicity. Receiver operating characteristic analysis and logistic regression were carried out for both contouring methods. Results: Grade ≥3more » small bowel toxicity occurred in 16% (11/67) of patients in the study. A highly significant dose-volume relationship between small bowel irradiation and acute small bowel toxicity was supported by the use of both small bowel loop and peritoneal space contouring techniques. Receiver operating characteristic analysis demonstrated that, for both contouring methods, the greatest sensitivity for predicting toxicity was associated with the volume receiving between 15 and 25 Gy. Conclusion: DVH analysis of peritoneal space volumes accurately predicts grade ≥3 small bowel toxicity in patients with rectal cancer receiving neoadjuvant chemoradiation therapy, suggesting that the contours of the peritoneal space provide a reasonable surrogate for the contours of individual small bowel loops. The study finds that a small bowel V15 less than 275 cc and a peritoneal space V15 less than 830 cc are associated with a less than 10% risk of grade ≥3 acute toxicity.« less

  8. Surface Modification of Silicon Pillar Arrays To Enhance Fluorescence Detection of Uranium and DNA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lincoln, Danielle R.; Charlton, Jennifer J.; Hatab, Nahla A.

    There is an ever-growing need for detection methods that are both sensitive and efficient, such that reagent and sample consumption is minimized. Nanopillar arrays offer an attractive option to fill this need by virtue of their small scale in conjunction with their field enhancement intensity gains. This work investigates the use of nanopillar substrates for the detection of the uranyl ion and DNA, two analytes unalike but for their low quantum efficiencies combined with the need for high-throughput analyses. Here in this paper, the adaptability of these platforms was explored, as methods for the successful surface immobilization of both analytesmore » were developed and compared, resulting in a limit of detection for the uranyl ion of less than 1 ppm with a 0.2 μL sample volume. Moreover, differentiation between single-stranded and double-stranded DNA was possible, including qualitative identification between double-stranded DNA and DNA of the same sequence, but with a 10-base-pair mismatch.« less

  9. Surface Modification of Silicon Pillar Arrays To Enhance Fluorescence Detection of Uranium and DNA

    DOE PAGES

    Lincoln, Danielle R.; Charlton, Jennifer J.; Hatab, Nahla A.; ...

    2017-10-27

    There is an ever-growing need for detection methods that are both sensitive and efficient, such that reagent and sample consumption is minimized. Nanopillar arrays offer an attractive option to fill this need by virtue of their small scale in conjunction with their field enhancement intensity gains. This work investigates the use of nanopillar substrates for the detection of the uranyl ion and DNA, two analytes unalike but for their low quantum efficiencies combined with the need for high-throughput analyses. Here in this paper, the adaptability of these platforms was explored, as methods for the successful surface immobilization of both analytesmore » were developed and compared, resulting in a limit of detection for the uranyl ion of less than 1 ppm with a 0.2 μL sample volume. Moreover, differentiation between single-stranded and double-stranded DNA was possible, including qualitative identification between double-stranded DNA and DNA of the same sequence, but with a 10-base-pair mismatch.« less

  10. Electrochemical product detection of an asymmetric convective polymerase chain reaction.

    PubMed

    Duwensee, Heiko; Mix, Maren; Stubbe, Marco; Gimsa, Jan; Adler, Marcel; Flechsig, Gerd-Uwe

    2009-10-15

    For the first time, we describe the application of heated microwires for an asymmetric convective polymerase chain reaction (PCR) in a modified PCR tube in a small volume. The partly single-stranded product was labeled with the electrochemically active compound osmium tetroxide bipyridine using a partially complementary protective strand with five mismatches compared to the single-stranded product. The labeled product could be successfully detected at a gold electrode modified with a complementary single-stranded capture probe immobilized via a thiol-linker. Our simple thermo-convective PCR yielded electrochemically detectable products after only 5-10 min. A significant discrimination between complementary and non-complementary target was possible using different immobilized capture probes. The total product yield was approx. half the amount of the classical thermocycler PCR. Numerical simulations describing the thermally driven convective PCR explain the received data. Discrimination between complementary capture probes and non-complementary capture probes was performed using square-wave voltammetry. The coupling of asymmetric thermo-convective PCR with electrochemical detection is very promising for future compact DNA sensor devices.

  11. Evaluation of a near-infrared-type contrast medium extravasation detection system using a swine model.

    PubMed

    Ishihara, Toshihiro; Kobayashi, Tatsushi; Ikeno, Naoya; Hayashi, Takayuki; Sakakibara, Masahiro; Niki, Noboru; Satake, Mitsuo; Moriyama, Noriyuki

    2014-01-01

    To refine the development and evaluate the near-infrared (NIR) extravasation detection system and its ability to detect extravasation during a contrast-enhanced computed tomography (CT) examination. The NIR extravasation detection system projects the NIR light through the surface of the human skin then, using its sensory system, will monitor the changes in the amount of NIR that reflected, which varies based on absorption properties.Seven female pigs were used to evaluate the contrast media extravasation detection system, using a 20-gauge intravenous catheter, when injected at a rate of 1 mL/s into 4 different locations just under the skin in the thigh section. Using 3-dimensional CT images, we evaluated the extravasations between time and volume, depth and volume, and finally depth and time to detect. We confirmed that the NIR light, 950-nm wavelength, used by the extravasation detection system is well absorbed by contrast media, making changes easy to detect. The average time to detect an extravasation was 2.05 seconds at a depth of 2.0 mm below the skin with a volume of 1.3 mL, 2.57 seconds at a depth between 2.1 and 5 mm below the skin and a volume of 3.47 mL, 10.5 seconds for depths greater than 5.1 mm and a volume of 11.1 mL. The detection accuracy was significantly deteriorated when the depth exceeded 5.0 mm (Tukey-Kramer, P < 0.05) CONCLUSIONS: The extravasation system detection system that is using NIR has a high level of detection sensitivity. The sensitivity enables the system to detect extravasation at depths less than 2 mm with a volume of 1.5 mL and at depths less than 5 mm with a volume of 3.5 mL. The extravasation detection system could be suitable for use during examinations.

  12. Axion searches with microwave filters: the RADES project

    NASA Astrophysics Data System (ADS)

    Álvarez Melcón, Alejandro; Arguedas Cuendis, Sergio; Cogollos, Cristian; Díaz-Morcillo, Alejandro; Döbrich, Babette; Gallego, Juan Daniel; Gimeno, Benito; Irastorza, Igor G.; José Lozano-Guerrero, Antonio; Malbrunot, Chloé; Navarro, Pablo; Peña Garay, Carlos; Redondo, Javier; Vafeiadis, Theodoros; Wuensch, Walter

    2018-05-01

    We propose, design and construct a variant of the conventional axion haloscope concept that could be competitive in the search for dark matter axions of masses in the decade 10–100 μeV. Theses masses are located somewhat above the mass range in which existing experiments have reached sensitivity to benchmark QCD axion models. Our haloscope consists of an array of small microwave cavities connected by rectangular irises, in an arrangement commonly used in radio-frequency filters. The size of the unit cavity determines the main resonant frequency, while the possibility to connect a large number of cavities allows to reach large detection volumes. We develop the theoretical framework of the detection concept, and present design prescriptions to optimize detection capabilities. We describe the design and realization of a first small-scale prototype of this concept, called Relic Axion Detector Exploratory Setup (RADES). It consists of a copper-coated stainless steel five-cavities microwave filter with the detecting mode operating at around 8.4 GHz. This structure has been electromagnetically characterized at 2 K and 298 K, and it is now placed in ultra-high vacuum in one of the twin-bores of the 9 T CAST dipole magnet at CERN. We describe the data acquisition system developed for relic axion detection, and present preliminary results of the electromagnetic properties of the microwave filter, which show the potential of filters to reach QCD axion window sensitivity at X-band frequencies.

  13. Study and Experiment on Non-Contact Voltage Sensor Suitable for Three-Phase Transmission Line

    PubMed Central

    Zhou, Qiang; He, Wei; Xiao, Dongping; Li, Songnong; Zhou, Kongjun

    2015-01-01

    A voltage transformer, as voltage signal detection equipment, plays an important role in a power system. Presently, more and more electric power systems are adopting potential transformer and capacitance voltage transformers. Transformers are often large in volume and heavyweight, their insulation design is difficult, and an iron core or multi-grade capacitance voltage division structure is generally adopted. As a result, the detection accuracy of transformer is reduced, a huge phase difference exists between detection signal and voltage signal to be measured, and the detection signal cannot accurately and timely reflect the change of conductor voltage signal to be measured. By aiming at the current problems of electric transformation, based on electrostatic induction principle, this paper designed a non-contact voltage sensor and gained detection signal of the sensor through electrostatic coupling for the electric field generated by electric charges of the conductor to be measured. The insulation structure design of the sensor is simple and its volume is small; phase difference of sensor measurement is effectively reduced through optimization design of the electrode; and voltage division ratio and measurement accuracy are increased. The voltage sensor was tested on the experimental platform of simulating three-phase transmission line. According to the result, the designed non-contact voltage sensor can realize accurate and real-time measurement for the conductor voltage. It can be applied to online monitoring for the voltage of three-phase transmission line or three-phase distribution network line, which is in accordance with the development direction of the smart grid. PMID:26729119

  14. Study and Experiment on Non-Contact Voltage Sensor Suitable for Three-Phase Transmission Line.

    PubMed

    Zhou, Qiang; He, Wei; Xiao, Dongping; Li, Songnong; Zhou, Kongjun

    2015-12-30

    A voltage transformer, as voltage signal detection equipment, plays an important role in a power system. Presently, more and more electric power systems are adopting potential transformer and capacitance voltage transformers. Transformers are often large in volume and heavyweight, their insulation design is difficult, and an iron core or multi-grade capacitance voltage division structure is generally adopted. As a result, the detection accuracy of transformer is reduced, a huge phase difference exists between detection signal and voltage signal to be measured, and the detection signal cannot accurately and timely reflect the change of conductor voltage signal to be measured. By aiming at the current problems of electric transformation, based on electrostatic induction principle, this paper designed a non-contact voltage sensor and gained detection signal of the sensor through electrostatic coupling for the electric field generated by electric charges of the conductor to be measured. The insulation structure design of the sensor is simple and its volume is small; phase difference of sensor measurement is effectively reduced through optimization design of the electrode; and voltage division ratio and measurement accuracy are increased. The voltage sensor was tested on the experimental platform of simulating three-phase transmission line. According to the result, the designed non-contact voltage sensor can realize accurate and real-time measurement for the conductor voltage. It can be applied to online monitoring for the voltage of three-phase transmission line or three-phase distribution network line, which is in accordance with the development direction of the smart grid.

  15. Analysis of exhaled breath by laser detection

    NASA Astrophysics Data System (ADS)

    Thrall, Karla D.; Toth, James J.; Sharpe, Steven W.

    1996-04-01

    The goal of our work is two fold: (1) to develop a portable rapid laser based breath analyzer for monitoring metabolic processes, and (2) predict these metabolic processes through physiologically based pharmacokinetic (PBPK) modeling. Small infrared active molecules such as ammonia, carbon monoxide, carbon dioxide, methane and ethane are present in exhaled breath and can be readily detected by laser absorption spectroscopy. In addition, many of the stable isotopomers of these molecules can be accurately detected, making it possible to follow specific metabolic processes. Potential areas of applications for this technology include the diagnosis of certain pathologies (e.g. Helicobacter Pylori infection), detection of trauma due to either physical or chemical causes and monitoring nutrient uptake (i.e., malnutrition). In order to understand the origin and elucidate the metabolic processes associated with these small molecules, we are employing physiologically based pharmacokinetic (PBPK) models. A PBPK model is founded on known physiological processes (i.e., blood flow rates, tissue volumes, breathing rate, etc.), chemical-specific processes (i.e., tissue solubility coefficients, molecular weight, chemical density, etc.), and on metabolic processes (tissue site and rate of metabolic biotransformation). Since many of these processes are well understood, a PBPK model can be developed and validated against the more readily available experimental animal data, and then by extrapolating the parameters to apply to man, the model can predict chemical behavior in humans.

  16. Measuring and Modeling Xenon Uptake in Plastic Beta-Cells

    NASA Astrophysics Data System (ADS)

    Suarez, R.; Hayes, J. C.; Harper, W. W.; Humble, P.; Ripplinger, M. D.; Stephenson, D. E.; Williams, R. M.

    2013-12-01

    The precision of the stable xenon volume measurement in atmospheric monitoring radio-xenon systems is a critical parameter used to determine the activity concentration of a radio-xenon sample. Typically these types of systems use a plastic scintillating beta-cell as part of a beta-gamma detection scheme to measure the radioactivity present in the gas sample. Challenges arise when performing the stable xenon calculation during or after radioactive counting of the sample due to xenon uptake into the plastic beta-cells. Plastic beta cells can adsorb as much as 5% of the sample during counting. If quantification is performed after counting, the uptake of xenon into the plastic results in an underestimation of the xenon volume measurement. This behavior also causes what is typically known as 'memory effect' in the cell. Experiments were conducted using a small volume low pressure range thermal conductivity sensor to quantify the amount of xenon uptake into the cell over a given period of time. Understanding the xenon uptake in the cell provides a better estimate of the stable volume which improves the overall measurement capability of the system. The results from these experiments along with modeling will be presented.

  17. Fast automated dual-syringe based dispersive liquid-liquid microextraction coupled with gas chromatography-mass spectrometry for the determination of polycyclic aromatic hydrocarbons in environmental water samples.

    PubMed

    Guo, Liang; Tan, Shufang; Li, Xiao; Lee, Hian Kee

    2016-03-18

    An automated procedure, combining low density solvent based solvent demulsification dispersive liquid-liquid microextraction (DLLME) with gas chromatography-mass spectrometry analysis, was developed for the determination of polycyclic aromatic hydrocarbons (PAHs) in environmental water samples. Capitalizing on a two-rail commercial autosampler, fast solvent transfer using a large volume syringe dedicated to the DLLME process, and convenient extract collection using a small volume microsyringe for better GC performance were enabled. Extraction parameters including the type and volume of extraction solvent, the type and volume of dispersive solvent and demulsification solvent, extraction and demulsification time, and the speed of solvent injection were investigated and optimized. Under the optimized conditions, the linearity ranged from 0.1 to 50 μg/L, 0.2 to 50 μg/L, and 0.5 to 50 μg/L, depending on the analytes. Limits of detection were determined to be between 0.023 and 0.058 μg/L. The method was applied to determine PAHs in environmental water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Optimal ventilation of the anesthetized pediatric patient.

    PubMed

    Feldman, Jeffrey M

    2015-01-01

    Mechanical ventilation of the pediatric patient is challenging because small changes in delivered volume can be a significant fraction of the intended tidal volume. Anesthesia ventilators have traditionally been poorly suited to delivering small tidal volumes accurately, and pressure-controlled ventilation has become used commonly when caring for pediatric patients. Modern anesthesia ventilators are designed to deliver small volumes accurately to the patient's airway by compensating for the compliance of the breathing system and delivering tidal volume independent of fresh gas flow. These technology advances provide the opportunity to implement a lung-protective ventilation strategy in the operating room based upon control of tidal volume. This review will describe the capabilities of the modern anesthesia ventilator and the current understanding of lung-protective ventilation. An optimal approach to mechanical ventilation for the pediatric patient is described, emphasizing the importance of using bedside monitors to optimize the ventilation strategy for the individual patient.

  19. Development of gas chromatography-flame ionization detection system with a single column and liquid nitrogen-free for measuring atmospheric C2-C12 hydrocarbons.

    PubMed

    Liu, Chengtang; Mu, Yujing; Zhang, Chenglong; Zhang, Zhibo; Zhang, Yuanyuan; Liu, Junfeng; Sheng, Jiujiang; Quan, Jiannong

    2016-01-04

    A liquid nitrogen-free GC-FID system equipped with a single column has been developed for measuring atmospheric C2-C12 hydrocarbons. The system is consisted of a cooling unit, a sampling unit and a separation unit. The cooling unit is used to meet the temperature needs of the sampling unit and the separation unit. The sampling unit includes a dehydration tube and an enrichment tube. No breakthrough of the hydrocarbons was detected when the temperature of the enrichment tube was kept at -90 °C and sampling volume was 400 mL. The separation unit is a small round oven attached on the cooling column. A single capillary column (OV-1, 30 m × 0.32 mm I.D.) was used to separate the hydrocarbons. An optimal program temperature (-60 ∼ 170 °C) of the oven was achieved to efficiently separate C2-C12 hydrocarbons. There were good linear correlations (R(2)=0.993-0.999) between the signals of the hydrocarbons and the enrichment amount of hydrocarbons, and the relative standard deviation (RSD) was less than 5%, and the method detection limits (MDLs) for the hydrocarbons were in the range of 0.02-0.10 ppbv for sampling volume of 400 mL. Field measurements were also conducted and more than 50 hydrocarbons from C2 to C12 were detected in Beijing city. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Endoclips vs large or small-volume epinephrine in peptic ulcer recurrent bleeding

    PubMed Central

    Ljubicic, Neven; Budimir, Ivan; Biscanin, Alen; Nikolic, Marko; Supanc, Vladimir; Hrabar, Davor; Pavic, Tajana

    2012-01-01

    AIM: To compare the recurrent bleeding after endoscopic injection of different epinephrine volumes with hemoclips in patients with bleeding peptic ulcer. METHODS: Between January 2005 and December 2009, 150 patients with gastric or duodenal bleeding ulcer with major stigmata of hemorrhage and nonbleeding visible vessel in an ulcer bed (Forrest IIa) were included in the study. Patients were randomized to receive a small-volume epinephrine group (15 to 25 mL injection group; Group 1, n = 50), a large-volume epinephrine group (30 to 40 mL injection group; Group 2, n = 50) and a hemoclip group (Group 3, n = 50). The rate of recurrent bleeding, as the primary outcome, was compared between the groups of patients included in the study. Secondary outcomes compared between the groups were primary hemostasis rate, permanent hemostasis, need for emergency surgery, 30 d mortality, bleeding-related deaths, length of hospital stay and transfusion requirements. RESULTS: Initial hemostasis was obtained in all patients. The rate of early recurrent bleeding was 30% (15/50) in the small-volume epinephrine group (Group 1) and 16% (8/50) in the large-volume epinephrine group (Group 2) (P = 0.09). The rate of recurrent bleeding was 4% (2/50) in the hemoclip group (Group 3); the difference was statistically significant with regard to patients treated with either small-volume or large-volume epinephrine solution (P = 0.0005 and P = 0.045, respectively). Duration of hospital stay was significantly shorter among patients treated with hemoclips than among patients treated with epinephrine whereas there were no differences in transfusion requirement or even 30 d mortality between the groups. CONCLUSION: Endoclip is superior to both small and large volume injection of epinephrine in the prevention of recurrent bleeding in patients with peptic ulcer. PMID:22611315

  1. Age-related cognitive decline coincides with accelerated volume loss of the dorsal but not ventral hippocampus in mice.

    PubMed

    Reichel, J M; Bedenk, B T; Czisch, M; Wotjak, C T

    2017-01-01

    Even in the absence of neurodegenerative diseases, progressing age often coincides with cognitive decline and morphological changes. However, longitudinal studies that directly link these two processes are missing. In this proof-of-concept study we therefore performed repeated within-subject testing of healthy male R26R mice in a spatial learning task in combination with manganese-enhanced volumetric MRI analyses at the ages of 8, 16, and 24 months. We grouped the mice into good and poor performers (n = 6, each), based on their spatial learning abilities at the age of 24 months. Using this stratification, we failed to detect a priori volume differences, but observed a significant decrease in total hippocampal volume over time for both groups. Interestingly, this volume decrease was specific for the dorsal hippocampus and significantly accelerated in poor performers between 16 and 24 months of age. This is the first time that individual changes in hippocampal volume were traced alongside cognitive performance within the same subjects over 1½ years. Our study points to a causal link between volume loss of the dorsal hippocampus and cognitive impairments. In addition, it suggests accelerated degenerative processes rather than a priori volume differences as determining trajectories of age-related cognitive decline. Despite the relatively small sample sizes, the strong behavioral and moderate morphological alterations demonstrate the general feasibility of longitudinal studies of age-related decline in cognition and hippocampus integrity. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  2. Pulsed Direct Current Electrospray: Enabling Systematic Analysis of Small Volume Sample by Boosting Sample Economy.

    PubMed

    Wei, Zhenwei; Xiong, Xingchuang; Guo, Chengan; Si, Xingyu; Zhao, Yaoyao; He, Muyi; Yang, Chengdui; Xu, Wei; Tang, Fei; Fang, Xiang; Zhang, Sichun; Zhang, Xinrong

    2015-11-17

    We had developed pulsed direct current electrospray ionization mass spectrometry (pulsed-dc-ESI-MS) for systematically profiling and determining components in small volume sample. Pulsed-dc-ESI utilized constant high voltage to induce the generation of single polarity pulsed electrospray remotely. This method had significantly boosted the sample economy, so as to obtain several minutes MS signal duration from merely picoliter volume sample. The elongated MS signal duration enable us to collect abundant MS(2) information on interested components in a small volume sample for systematical analysis. This method had been successfully applied for single cell metabolomics analysis. We had obtained 2-D profile of metabolites (including exact mass and MS(2) data) from single plant and mammalian cell, concerning 1034 components and 656 components for Allium cepa and HeLa cells, respectively. Further identification had found 162 compounds and 28 different modification groups of 141 saccharides in a single Allium cepa cell, indicating pulsed-dc-ESI a powerful tool for small volume sample systematical analysis.

  3. Research highlights: increasing paper possibilities.

    PubMed

    Wu, Chueh-Yu; Adeyiga, Oladunni; Lin, Jonathan; Di Carlo, Dino

    2014-09-07

    In this issue we highlight three recent papers that demonstrate new strategies to extend the capabilities of paper microfluidics. Paper (a mesh of porous fibers) has a long history as a substrate to perform biomolecular assays. Traditional lateral flow immunoassays (LFAs) are widely used for rapid diagnostic tests, and perform well when a yes or no answer is required and the analyte of interest is at relatively high concentrations. High concentrations are required because usually only a small volume of analyte-containing fluid flows past the detection region, leading to a limited signal. Further, the small pores within paper matrices prevent the use of paper to control the flow of larger particles and cells, limiting the use of paper microfluidics for cell-based diagnostics. The work we highlight addresses these important unmet challenges in paper microfluidics: enriching low concentration analytes to a higher concentration in a smaller volume that can be processed effectively, and using paper to pump flows in larger channels amenable to cells. Applying these new approaches may allow diagnosis of disease states currently technically unachievable using current LFA systems, while maintaining many of the "un-instrumented" advantages of an assay on self-wicking paper.

  4. Fragment size distribution in viscous bag breakup of a drop

    NASA Astrophysics Data System (ADS)

    Kulkarni, Varun; Bulusu, Kartik V.; Plesniak, Michael W.; Sojka, Paul E.

    2015-11-01

    In this study we examine the drop size distribution resulting from the fragmentation of a single drop in the presence of a continuous air jet. Specifically, we study the effect of Weber number, We, and Ohnesorge number, Oh on the disintegration process. The regime of breakup considered is observed between 12 <= We <= 16 for Oh <= 0.1. Experiments are conducted using phase Doppler anemometry. Both the number and volume fragment size probability distributions are plotted. The volume probability distribution revealed a bi-modal behavior with two distinct peaks: one corresponding to the rim fragments and the other to the bag fragments. This behavior was suppressed in the number probability distribution. Additionally, we employ an in-house particle detection code to isolate the rim fragment size distribution from the total probability distributions. Our experiments showed that the bag fragments are smaller in diameter and larger in number, while the rim fragments are larger in diameter and smaller in number. Furthermore, with increasing We for a given Ohwe observe a large number of small-diameter drops and small number of large-diameter drops. On the other hand, with increasing Oh for a fixed We the opposite is seen.

  5. Phylogenetic ctDNA analysis depicts early-stage lung cancer evolution.

    PubMed

    Abbosh, Christopher; Birkbak, Nicolai J; Wilson, Gareth A; Jamal-Hanjani, Mariam; Constantin, Tudor; Salari, Raheleh; Le Quesne, John; Moore, David A; Veeriah, Selvaraju; Rosenthal, Rachel; Marafioti, Teresa; Kirkizlar, Eser; Watkins, Thomas B K; McGranahan, Nicholas; Ward, Sophia; Martinson, Luke; Riley, Joan; Fraioli, Francesco; Al Bakir, Maise; Grönroos, Eva; Zambrana, Francisco; Endozo, Raymondo; Bi, Wenya Linda; Fennessy, Fiona M; Sponer, Nicole; Johnson, Diana; Laycock, Joanne; Shafi, Seema; Czyzewska-Khan, Justyna; Rowan, Andrew; Chambers, Tim; Matthews, Nik; Turajlic, Samra; Hiley, Crispin; Lee, Siow Ming; Forster, Martin D; Ahmad, Tanya; Falzon, Mary; Borg, Elaine; Lawrence, David; Hayward, Martin; Kolvekar, Shyam; Panagiotopoulos, Nikolaos; Janes, Sam M; Thakrar, Ricky; Ahmed, Asia; Blackhall, Fiona; Summers, Yvonne; Hafez, Dina; Naik, Ashwini; Ganguly, Apratim; Kareht, Stephanie; Shah, Rajesh; Joseph, Leena; Marie Quinn, Anne; Crosbie, Phil A; Naidu, Babu; Middleton, Gary; Langman, Gerald; Trotter, Simon; Nicolson, Marianne; Remmen, Hardy; Kerr, Keith; Chetty, Mahendran; Gomersall, Lesley; Fennell, Dean A; Nakas, Apostolos; Rathinam, Sridhar; Anand, Girija; Khan, Sajid; Russell, Peter; Ezhil, Veni; Ismail, Babikir; Irvin-Sellers, Melanie; Prakash, Vineet; Lester, Jason F; Kornaszewska, Malgorzata; Attanoos, Richard; Adams, Haydn; Davies, Helen; Oukrif, Dahmane; Akarca, Ayse U; Hartley, John A; Lowe, Helen L; Lock, Sara; Iles, Natasha; Bell, Harriet; Ngai, Yenting; Elgar, Greg; Szallasi, Zoltan; Schwarz, Roland F; Herrero, Javier; Stewart, Aengus; Quezada, Sergio A; Peggs, Karl S; Van Loo, Peter; Dive, Caroline; Lin, C Jimmy; Rabinowitz, Matthew; Aerts, Hugo J W L; Hackshaw, Allan; Shaw, Jacqui A; Zimmermann, Bernhard G; Swanton, Charles

    2017-04-26

    The early detection of relapse following primary surgery for non-small-cell lung cancer and the characterization of emerging subclones, which seed metastatic sites, might offer new therapeutic approaches for limiting tumour recurrence. The ability to track the evolutionary dynamics of early-stage lung cancer non-invasively in circulating tumour DNA (ctDNA) has not yet been demonstrated. Here we use a tumour-specific phylogenetic approach to profile the ctDNA of the first 100 TRACERx (Tracking Non-Small-Cell Lung Cancer Evolution Through Therapy (Rx)) study participants, including one patient who was also recruited to the PEACE (Posthumous Evaluation of Advanced Cancer Environment) post-mortem study. We identify independent predictors of ctDNA release and analyse the tumour-volume detection limit. Through blinded profiling of postoperative plasma, we observe evidence of adjuvant chemotherapy resistance and identify patients who are very likely to experience recurrence of their lung cancer. Finally, we show that phylogenetic ctDNA profiling tracks the subclonal nature of lung cancer relapse and metastasis, providing a new approach for ctDNA-driven therapeutic studies.

  6. Small Business Management Volume III: Curriculum. An Adult Education Program.

    ERIC Educational Resources Information Center

    Persons, Edgar A.; Swanson, Gordon I.

    The small business management adult education program outlined in this curriculum guide is designed to help small business entrepreneurs solve their business management problems and attain the goals they have established for their businesses and their families. (An instructor's manual and practice problems are in separate volumes.) The 3-year…

  7. 40 CFR 80.250 - How is the small refiner sulfur baseline and volume determined?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 17 2012-07-01 2012-07-01 false How is the small refiner sulfur... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Sulfur Hardship Provisions § 80.250 How is the small refiner sulfur baseline and volume determined? (a)(1) The...

  8. 40 CFR 80.250 - How is the small refiner sulfur baseline and volume determined?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 16 2011-07-01 2011-07-01 false How is the small refiner sulfur... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Sulfur Hardship Provisions § 80.250 How is the small refiner sulfur baseline and volume determined? (a)(1) The...

  9. 40 CFR 80.250 - How is the small refiner sulfur baseline and volume determined?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 17 2014-07-01 2014-07-01 false How is the small refiner sulfur... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Sulfur Hardship Provisions § 80.250 How is the small refiner sulfur baseline and volume determined? (a)(1) The...

  10. 40 CFR 80.250 - How is the small refiner sulfur baseline and volume determined?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 17 2013-07-01 2013-07-01 false How is the small refiner sulfur... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Sulfur Hardship Provisions § 80.250 How is the small refiner sulfur baseline and volume determined? (a)(1) The...

  11. 40 CFR 80.250 - How is the small refiner sulfur baseline and volume determined?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false How is the small refiner sulfur... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Sulfur Hardship Provisions § 80.250 How is the small refiner sulfur baseline and volume determined? (a)(1) The...

  12. Substantial Expansion of Detectable Size Range in Ionic Current Sensing through Pores by Using a Microfluidic Bridge Circuit.

    PubMed

    Yasaki, Hirotoshi; Yasui, Takao; Yanagida, Takeshi; Kaji, Noritada; Kanai, Masaki; Nagashima, Kazuki; Kawai, Tomoji; Baba, Yoshinobu

    2017-10-11

    Measuring ionic currents passing through nano- or micropores has shown great promise for the electrical discrimination of various biomolecules, cells, bacteria, and viruses. However, conventional measurements have shown there is an inherent limitation to the detectable particle volume (1% of the pore volume), which critically hinders applications to real mixtures of biomolecule samples with a wide size range of suspended particles. Here we propose a rational methodology that can detect samples with the detectable particle volume of 0.01% of the pore volume by measuring a transient current generated from the potential differences in a microfluidic bridge circuit. Our method substantially suppresses the background ionic current from the μA level to the pA level, which essentially lowers the detectable particle volume limit even for relatively large pore structures. Indeed, utilizing a microscale long pore structure (volume of 5.6 × 10 4 aL; height and width of 2.0 × 2.0 μm; length of 14 μm), we successfully detected various samples including polystyrene nanoparticles (volume: 4 aL), bacteria, cancer cells, and DNA molecules. Our method will expand the applicability of ionic current sensing systems for various mixed biomolecule samples with a wide size range, which have been difficult to measure by previously existing pore technologies.

  13. Lab-on-a-chip modules for detection of highly pathogenic bacteria: from sample preparation to detection

    NASA Astrophysics Data System (ADS)

    Julich, S.; Kopinč, R.; Hlawatsch, N.; Moche, C.; Lapanje, A.; Gärtner, C.; Tomaso, H.

    2014-05-01

    Lab-on-a-chip systems are innovative tools for the detection and identification of microbial pathogens in human and veterinary medicine. The major advantages are small sample volume and a compact design. Several fluidic modules have been developed to transform analytical procedures into miniaturized scale including sampling, sample preparation, target enrichment, and detection procedures. We present evaluation data for single modules that will be integrated in a chip system for the detection of pathogens. A microfluidic chip for purification of nucleic acids was established for cell lysis using magnetic beads. This assay was evaluated with spiked environmental aerosol and swab samples. Bacillus thuringiensis was used as simulant for Bacillus anthracis, which is closely related but non-pathogenic for humans. Stationary PCR and a flow-through PCR chip module were investigated for specific detection of six highly pathogenic bacteria. The conventional PCR assays could be transferred into miniaturized scale using the same temperature/time profile. We could demonstrate that the microfluidic chip modules are suitable for the respective purposes and are promising tools for the detection of bacterial pathogens. Future developments will focus on the integration of these separate modules to an entire lab-on-a-chip system.

  14. Counting Particles Emitted by Stratospheric Aircraft and Measuring Size of Particles Emitted by Stratospheric Aircraft

    NASA Technical Reports Server (NTRS)

    Wilson, James Charles

    1994-01-01

    There were two principal objectives of the cooperative agreement between NASA and the University of Denver. The first goal was to modify the design of the ER-2 condensation nuclei counter (CNC) so that the effective lower detection limit would be improved at high altitudes. This improvement was sought because, in the instrument used prior to 1993, diffusion losses prevented the smallest detectable particles from reaching the detection volume of the instrument during operation at low pressure. Therefore, in spite of the sensor's ability to detect particles as small as 0.008 microns in diameter, many of these particles were lost in transport to the sensing region and were not counted. Most of the particles emitted by aircraft are smaller than 0.1 micron in diameter. At the start date of this work, May 1990, continuous sizing techniques available on the ER-2 were only capable of detecting particles larger than 0.17 micron. Thus, the second objective of this work was to evaluate candidate sizing techniques in an effort to gain additional information concerning the size of particles emitted by aircraft.

  15. Non-Destructive Detection of Wire Rope Discontinuities from Residual Magnetic Field Images Using the Hilbert-Huang Transform and Compressed Sensing

    PubMed Central

    Zhang, Juwei; Tan, Xiaojiang; Zheng, Pengbo

    2017-01-01

    Electromagnetic methods are commonly employed to detect wire rope discontinuities. However, determining the residual strength of wire rope based on the quantitative recognition of discontinuities remains problematic. We have designed a prototype device based on the residual magnetic field (RMF) of ferromagnetic materials, which overcomes the disadvantages associated with in-service inspections, such as large volume, inconvenient operation, low precision, and poor portability by providing a relatively small and lightweight device with improved detection precision. A novel filtering system consisting of the Hilbert-Huang transform and compressed sensing wavelet filtering is presented. Digital image processing was applied to achieve the localization and segmentation of defect RMF images. The statistical texture and invariant moment characteristics of the defect images were extracted as the input of a radial basis function neural network. Experimental results show that the RMF device can detect defects in various types of wire rope and prolong the service life of test equipment by reducing the friction between the detection device and the wire rope by accommodating a high lift-off distance. PMID:28300790

  16. Fast cholesterol detection using flow injection microfluidic device with functionalized carbon nanotubes based electrochemical sensor.

    PubMed

    Wisitsoraat, A; Sritongkham, P; Karuwan, C; Phokharatkul, D; Maturos, T; Tuantranont, A

    2010-12-15

    This work reports a new cholesterol detection scheme using functionalized carbon nanotube (CNT) electrode in a polydimethylsiloxane/glass based flow injection microfluidic chip. CNTs working, silver reference and platinum counter electrode layers were fabricated on the chip by sputtering and low temperature chemical vapor deposition methods. Cholesterol oxidase prepared in polyvinyl alcohol solution was immobilized on CNTs by in-channel flow technique. Cholesterol analysis based on flow injection chronoamperometric measurement was performed in 150-μm-wide and 150-μm-deep microchannels. Fast and sensitive real-time detection was achieved with high throughput of more than 60 samples per hour and small sample volume of 15 μl. The cholesterol sensor had a linear detection range between 50 and 400 mg/dl. In addition, low cross-sensitivities toward glucose, ascorbic acid, acetaminophen and uric acid were confirmed. The proposed system is promising for clinical diagnostics of cholesterol with high speed real-time detection capability, very low sample consumption, high sensitivity, low interference and good stability. Copyright © 2010 Elsevier B.V. All rights reserved.

  17. Robust high-performance nanoliter-volume single-cell multiple displacement amplification on planar substrates.

    PubMed

    Leung, Kaston; Klaus, Anders; Lin, Bill K; Laks, Emma; Biele, Justina; Lai, Daniel; Bashashati, Ali; Huang, Yi-Fei; Aniba, Radhouane; Moksa, Michelle; Steif, Adi; Mes-Masson, Anne-Marie; Hirst, Martin; Shah, Sohrab P; Aparicio, Samuel; Hansen, Carl L

    2016-07-26

    The genomes of large numbers of single cells must be sequenced to further understanding of the biological significance of genomic heterogeneity in complex systems. Whole genome amplification (WGA) of single cells is generally the first step in such studies, but is prone to nonuniformity that can compromise genomic measurement accuracy. Despite recent advances, robust performance in high-throughput single-cell WGA remains elusive. Here, we introduce droplet multiple displacement amplification (MDA), a method that uses commercially available liquid dispensing to perform high-throughput single-cell MDA in nanoliter volumes. The performance of droplet MDA is characterized using a large dataset of 129 normal diploid cells, and is shown to exceed previously reported single-cell WGA methods in amplification uniformity, genome coverage, and/or robustness. We achieve up to 80% coverage of a single-cell genome at 5× sequencing depth, and demonstrate excellent single-nucleotide variant (SNV) detection using targeted sequencing of droplet MDA product to achieve a median allelic dropout of 15%, and using whole genome sequencing to achieve false and true positive rates of 9.66 × 10(-6) and 68.8%, respectively, in a G1-phase cell. We further show that droplet MDA allows for the detection of copy number variants (CNVs) as small as 30 kb in single cells of an ovarian cancer cell line and as small as 9 Mb in two high-grade serous ovarian cancer samples using only 0.02× depth. Droplet MDA provides an accessible and scalable method for performing robust and accurate CNV and SNV measurements on large numbers of single cells.

  18. Predicting clinical outcomes in chordoma patients receiving immunotherapy: a comparison between volumetric segmentation and RECIST.

    PubMed

    Fenerty, Kathleen E; Folio, Les R; Patronas, Nicholas J; Marté, Jennifer L; Gulley, James L; Heery, Christopher R

    2016-08-23

    The Response Evaluation Criteria in Solid Tumors (RECIST) are the current standard for evaluating disease progression or therapy response in patients with solid tumors. RECIST 1.1 calls for axial, longest-diameter (or perpendicular short axis of lymph nodes) measurements of a maximum of five tumors, which limits clinicians' ability to adequately measure disease burden, especially in patients with irregularly shaped tumors. This is especially problematic in chordoma, a disease for which RECIST does not always adequately capture disease burden because chordoma tumors are typically irregularly shaped and slow-growing. Furthermore, primary chordoma tumors tend to be adjacent to vital structures in the skull or sacrum that, when compressed, lead to significant clinical consequences. Volumetric segmentation is a newer technology that allows tumor burden to be measured in three dimensions on either MR or CT. Here, we compared the ability of RECIST measurements and tumor volumes to predict clinical outcomes in a cohort of 21 chordoma patients receiving immunotherapy. There was a significant difference in radiologic time to progression Kaplan-Meier curves between clinical outcome groups using volumetric segmentation (P = 0.012) but not RECIST (P = 0.38). In several cases, changes in volume were earlier and more sensitive reflections of clinical status. RECIST is a useful evaluation method when obvious changes are occurring in patients with chordoma. However, in many cases, RECIST does not detect small changes, and volumetric assessment was capable of detecting changes and predicting clinical outcome earlier than RECIST. Although this study was small and retrospective, we believe our results warrant further research in this area.

  19. Structural evaluation of an amyloid fibril model using small-angle x-ray scattering

    NASA Astrophysics Data System (ADS)

    Dahal, Eshan; Choi, Mina; Alam, Nadia; Bhirde, Ashwinkumar A.; Beaucage, Serge L.; Badano, Aldo

    2017-08-01

    Amyloid fibrils are highly structured protein aggregates associated with a wide range of diseases including Alzheimer’s and Parkinson’s. We report a structural investigation of an amyloid fibril model prepared from a commonly used plasma protein (bovine serum albumin (BSA)) using small-angle x-ray scattering (SAXS) technique. As a reference, the size estimates from SAXS are compared to dynamic light scattering (DLS) data and the presence of amyloid-like fibrils is confirmed using Congo red absorbance assay. Our SAXS results consistently show the structural transformation of BSA from spheroid to rod-like elongated structures during the fibril formation process. We observe the elongation of fibrils over two months with fibril length growing from 35.9  ±  3.0 nm to 51.5  ±  2.1 nm. Structurally metastable fibrils with distinct SAXS profiles have been identified. As proof of concept, we demonstrate the use of such distinct SAXS profiles to detect fibrils in the mixture solutions of two species by estimating their volume fractions. This easily detectable and well-characterized amyloid fibril model from BSA can be readily used as a control or standard reference to further investigate SAXS applications in the detection of structurally diverse amyloid fibrils associated with protein aggregation diseases.

  20. Analysis of small droplets with a new detector for liquid chromatography based on laser-induced breakdown spectroscopy

    NASA Astrophysics Data System (ADS)

    Janzen, Christoph; Fleige, Rüdiger; Noll, Reinhard; Schwenke, Heinrich; Lahmann, Wilhelm; Knoth, Joachim; Beaven, Peter; Jantzen, Eckard; Oest, Andreas; Koke, Peter

    2005-08-01

    The miniaturization of analytical techniques is a general trend in speciation analytics. We have developed a new analytical technique combining high pressure liquid chromatography (HPLC) with laser-induced breakdown spectroscopy (LIBS). This enables a molecule-specific separation followed by an element-specific analysis of smallest amounts of complex samples. The liquid flow coming from a HPLC pump is transformed into a continuous stream of small droplets (diameter 50-100 μm, volume 65-500 pl) using a piezoelectric pulsed nozzle. After the detection of single droplets with a droplet detector, a Q-switched Nd:YAG Laser is triggered to emit a synchronized laser pulse that irradiates a single droplet. The droplets are evaporated and transformed to the plasma state. The spectrum emitted from the plasma is collected by a spherical mirror and directed through the entrance slit of a Paschen-Runge spectrometer equipped with channel photomultipliers. The spectrometer detects 31 elements simultaneously covering a spectral range from 120 to 589 nm. Purging the measurement chamber with argon enables the detection of vacuum-UV lines. Since the sample is transferred to the plasma state without dilution, very low flow rates in the sub-μl/min range can be realised.

  1. An Assessment of Ground-Based Techniques for Detecting Other Planetary Systems. Volume 2: Position papers

    NASA Technical Reports Server (NTRS)

    Black, D. C.; Brunk, W. E.

    1980-01-01

    The capabilities of several astronomical interferomenter system concepts are assessed and the effects of the Earth's atmosphere on astrometric precision are examined in detail. Included is an examination of the use of small aperture interferometry to detect planets in binary star systems. It is estimated that, for differential astrometric observation, an amplitude interferometer having two separate telescopes should permit observations of stars as faint as 14th magnitude and a positional accuracy of 0.00005 arc-sec. Instrumental, atmospheric, and photon noise errors that apply to interferometric observation are examined. It is suggested that the effects of atmospheric turbulence may be eliminated with the use of two color refractometer systems. Several sites for future telescopes dedicated to the search for planetary systems are identified.

  2. New detection system and signal processing for the tokamak ISTTOK heavy ion beam diagnostic.

    PubMed

    Henriques, R B; Nedzelskiy, I S; Malaquias, A; Fernandes, H

    2012-10-01

    The tokamak ISTTOK havy ion beam diagnostic (HIBD) operates with a multiple cell array detector (MCAD) that allows for the plasma density and the plasma density fluctuations measurements simultaneously at different sampling volumes across the plasma. To improve the capability of the plasma density fluctuations investigations, a new detection system and new signal conditioning amplifier have been designed and tested. The improvements in MCAD design are presented which allow for nearly complete suppression of the spurious plasma background signal by applying a biasing potential onto special electrodes incorporated into MCAD. The new low cost and small size transimpedance amplifiers are described with the parameters of 400 kHz, 10(7) V/A, 0.4 nA of RMS noise, adequate for the plasma density fluctuations measurements.

  3. Photoacoustic imaging to detect rat brain activation after cocaine hydrochloride injection

    NASA Astrophysics Data System (ADS)

    Jo, Janggun; Yang, Xinmai

    2011-03-01

    Photoacoustic imaging (PAI) was employed to detect small animal brain activation after the administration of cocaine hydrochloride. Sprague Dawley rats were injected with different concentrations (2.5, 3.0, and 5.0 mg per kg body) of cocaine hydrochloride in saline solution through tail veins. The brain functional response to the injection was monitored by photoacoustic tomography (PAT) system with horizontal scanning of cerebral cortex of rat brain. Photoacoustic microscopy (PAM) was also used for coronal view images. The modified PAT system used multiple ultrasonic detectors to reduce the scanning time and maintain a good signal-to-noise ratio (SNR). The measured photoacoustic signal changes confirmed that cocaine hydrochloride injection excited high blood volume in brain. This result shows PAI can be used to monitor drug abuse-induced brain activation.

  4. Superhydrophobic SERS substrates based on silicon hierarchical nanostructures

    NASA Astrophysics Data System (ADS)

    Chen, Xuexian; Wen, Jinxiu; Zhou, Jianhua; Zheng, Zebo; An, Di; Wang, Hao; Xie, Weiguang; Zhan, Runze; Xu, Ningsheng; Chen, Jun; She, Juncong; Chen, Huanjun; Deng, Shaozhi

    2018-02-01

    Silicon nanostructures have been cultivated as promising surface enhanced Raman scattering (SERS) substrates in terms of their low-loss optical resonance modes, facile functionalization, and compatibility with today’s state-of-the-art CMOS techniques. However, unlike their plasmonic counterparts, the electromagnetic field enhancements induced by silicon nanostructures are relatively small, which restrict their SERS sensing limit to around 10-7 M. To tackle this problem, we propose here a strategy for improving the SERS performance of silicon nanostructures by constructing silicon hierarchical nanostructures with a superhydrophobic surface. The hierarchical nanostructures are binary structures consisted of silicon nanowires (NWs) grown on micropyramids (MPs). After being modified with perfluorooctyltriethoxysilane (PFOT), the nanostructure surface shows a stable superhydrophobicity with a high contact angle of ˜160°. The substrate can allow for concentrating diluted analyte solutions into a specific area during the evaporation of the liquid droplet, whereby the analytes are aggregated into a small volume and can be easily detected by the silicon nanostructure SERS substrate. The analyte molecules (methylene blue: MB) enriched from an aqueous solution lower than 10-8 M can be readily detected. Such a detection limit is ˜100-fold lower than the conventional SERS substrates made of silicon nanostructures. Additionally, the detection limit can be further improved by functionalizing gold nanoparticles onto silicon hierarchical nanostructures, whereby the superhydrophobic characteristics and plasmonic field enhancements can be combined synergistically to give a detection limit down to ˜10-11 M. A gold nanoparticle-functionalized superhydrophobic substrate was employed to detect the spiked melamine in liquid milk. The results showed that the detection limit can be as low as 10-5 M, highlighting the potential of the proposed superhydrophobic SERS substrate in practical food safety inspection applications.

  5. Evaluation of needle trap micro-extraction and automatic alveolar sampling for point-of-care breath analysis.

    PubMed

    Trefz, Phillip; Rösner, Lisa; Hein, Dietmar; Schubert, Jochen K; Miekisch, Wolfram

    2013-04-01

    Needle trap devices (NTDs) have shown many advantages such as improved detection limits, reduced sampling time and volume, improved stability, and reproducibility if compared with other techniques used in breath analysis such as solid-phase extraction and solid-phase micro-extraction. Effects of sampling flow (2-30 ml/min) and volume (10-100 ml) were investigated in dry gas standards containing hydrocarbons, aldehydes, and aromatic compounds and in humid breath samples. NTDs contained (single-bed) polymer packing and (triple-bed) combinations of divinylbenzene/Carbopack X/Carboxen 1000. Substances were desorbed from the NTDs by means of thermal expansion and analyzed by gas chromatography-mass spectrometry. An automated CO2-controlled sampling device for direct alveolar sampling at the point-of-care was developed and tested in pilot experiments. Adsorption efficiency for small volatile organic compounds decreased and breakthrough increased when sampling was done with polymer needles from a water-saturated matrix (breath) instead from dry gas. Humidity did not affect analysis with triple-bed NTDs. These NTDs showed only small dependencies on sampling flow and low breakthrough from 1-5 %. The new sampling device was able to control crucial parameters such as sampling flow and volume. With triple-bed NTDs, substance amounts increased linearly with increasing sample volume when alveolar breath was pre-concentrated automatically. When compared with manual sampling, automatic sampling showed comparable or better results. Thorough control of sampling and adequate choice of adsorption material is mandatory for application of needle trap micro-extraction in vivo. The new CO2-controlled sampling device allows direct alveolar sampling at the point-of-care without the need of any additional sampling, storage, or pre-concentration steps.

  6. [Effects of Losartan on expression of heme oxygenases in volume-overloaded rats with left-to-right shunt].

    PubMed

    Yuan, Li-Xing; Liu, Han-Min; Li, Mi; Gao, Ju; Zhou, Tong-Fu

    2005-09-01

    To study the expression of heme oxygenase-1 mRNA and pulmonary remodeling before and after surgical establishment of left-to-right shunt in volume-overloaded SD rats and rats with Losartan intervention. Left-to-right shunt volume-overloaded SD rat models were established by aortocaval shunt operation. Seven rats with shunt were placed on Losartan (Losartan group), 7 rats with but not given Losartan were included in the operation group, and 4 rats after sham operation served as controls. Pulmonary pressure and right ventricular pressure were measured during catheterization. The relative weights ventricles were determined after execution of the rats. Pulmonary vascular remodeling parameters, including percentage arterial wall thickness and percentage muscularized small arteries, were assessed by morphometry. Heme oxygenase-1 (HO-1) mRNA expression and heme oxygenase-2 (HO-2) mRNA expression were detected RT-PCR method. Pulmonary artery pressure and right ventricular relative weight decreased significantly in the rats of Losartan group; in addition, the percentage arterial wall thickness and percentage of muscularized small arteries in the Losartan group were reduced as compared with those in the operation group. The level 1 mRAN expression in rats with shunt was significantly higher than that in rats without shunt. The level mRNA expression in the Losartan group decreased remarkably as compared against that in the operation The level of HO-1 mRNA expression in lungs was significantly higher than that in ventricles. There statistically significant differences in HO-2 mRNA expression levels between the three rat groups. Losartan intervention can markedly reduce pulmonary pressure, inhibit vascular remodeling in volume-overloaded left-to-right shunt rats, and result in down-regulation of HO-1 mRNA expression.

  7. Quantitative volumetric imaging of normal, neoplastic and hyperplastic mouse prostate using ultrasound.

    PubMed

    Singh, Shalini; Pan, Chunliu; Wood, Ronald; Yeh, Chiuan-Ren; Yeh, Shuyuan; Sha, Kai; Krolewski, John J; Nastiuk, Kent L

    2015-09-21

    Genetically engineered mouse models are essential to the investigation of the molecular mechanisms underlying human prostate pathology and the effects of therapy on the diseased prostate. Serial in vivo volumetric imaging expands the scope and accuracy of experimental investigations of models of normal prostate physiology, benign prostatic hyperplasia and prostate cancer, which are otherwise limited by the anatomy of the mouse prostate. Moreover, accurate imaging of hyperplastic and tumorigenic prostates is now recognized as essential to rigorous pre-clinical trials of new therapies. Bioluminescent imaging has been widely used to determine prostate tumor size, but is semi-quantitative at best. Magnetic resonance imaging can determine prostate volume very accurately, but is expensive and has low throughput. We therefore sought to develop and implement a high throughput, low cost, and accurate serial imaging protocol for the mouse prostate. We developed a high frequency ultrasound imaging technique employing 3D reconstruction that allows rapid and precise assessment of mouse prostate volume. Wild-type mouse prostates were examined (n = 4) for reproducible baseline imaging, and treatment effects on volume were compared, and blinded data analyzed for intra- and inter-operator assessments of reproducibility by correlation and for Bland-Altman analysis. Examples of benign prostatic hyperplasia mouse model prostate (n = 2) and mouse prostate implantation of orthotopic human prostate cancer tumor and its growth (n =  ) are also demonstrated. Serial measurement volume of the mouse prostate revealed that high frequency ultrasound was very precise. Following endocrine manipulation, regression and regrowth of the prostate could be monitored with very low intra- and interobserver variability. This technique was also valuable to monitor the development of prostate growth in a model of benign prostatic hyperplasia. Additionally, we demonstrate accurate ultrasound image-guided implantation of orthotopic tumor xenografts and monitoring of subsequent tumor growth from ~10 to ~750 mm(3) volume. High frequency ultrasound imaging allows precise determination of normal, neoplastic and hyperplastic mouse prostate. Low cost and small image size allows incorporation of this imaging modality inside clean animal facilities, and thereby imaging of immunocompromised models. 3D reconstruction for volume determination is easily mastered, and both small and large relative changes in volume are accurately visualized. Ultrasound imaging does not rely on penetration of exogenous imaging agents, and so may therefore better measure poorly vascularized or necrotic diseased tissue, relative to bioluminescent imaging (IVIS). Our method is precise and reproducible with very low inter- and intra-observer variability. Because it is non-invasive, mouse models of prostatic disease states can be imaged serially, reducing inter-animal variability, and enhancing the power to detect small volume changes following therapeutic intervention.

  8. Archimedes Revisited: A Faster, Better, Cheaper Method of Accurately Measuring the Volume of Small Objects

    ERIC Educational Resources Information Center

    Hughes, Stephen W.

    2005-01-01

    A little-known method of measuring the volume of small objects based on Archimedes' principle is described, which involves suspending an object in a water-filled container placed on electronic scales. The suspension technique is a variation on the hydrostatic weighing technique used for measuring volume. The suspension method was compared with two…

  9. Spatiotemporal characteristics and vascular sources of neural-specific and -nonspecific fMRI signals at submillimeter columnar resolution

    PubMed Central

    Moon, Chan Hong; Fukuda, Mitsuhiro; Kim, Seong-Gi

    2012-01-01

    The neural specificity of hemodynamic-based functional magnetic resonance imaging (fMRI) signals are dependent on both the vascular regulation and the sensitivity of the applied fMRI technique to different types and sizes of blood vessels. In order to examine the specificity of MRI-detectable hemodynamic responses, submillimeter blood oxygenation-level dependent (BOLD) and cerebral blood volume (CBV) fMRI studies were performed in a well-established cat orientation column model at 9.4 Tesla. Neural-nonspecific and -specific signals were separated by comparing the fMRI responses of orthogonal orientation stimuli. The BOLD response was dominantly neural-nonspecific, mostly originating from pial and intracortical emerging veins, and thus was highly correlated with baseline blood volume. Uneven baseline CBV may displace or distort small functional domains in high-resolution BOLD maps. The CBV response in the parenchyma exhibited dual spatiotemporal characteristics, a fast and early neural-nonspecific response (with 4.3-s time constant) and a slightly slower and delayed neural-specific response (with 9.4-s time constant). The nonspecific CBV signal originates from early-responding arteries and arterioles, while the specific CBV response, which is not correlated with baseline blood volume, arises from late-responding microvessels including small pre-capillary arterioles and capillaries. Our data indicate that although the neural specificity of CBV fMRI signals is dependent on stimulation duration, high-resolution functional maps can be obtained from steady-state CBV studies. PMID:22960251

  10. Large-aperture MOEMS Fabry-Perot interferometer for miniaturized spectral imagers

    NASA Astrophysics Data System (ADS)

    Rissanen, Anna; Langner, Andreas; Viherkanto, Kai; Mannila, Rami

    2015-02-01

    VTT's optical MEMS Fabry-Perot interferometers (FPIs) are tunable optical filters, which enable miniaturization of spectral imagers into small, mass producible hand-held sensors with versatile optical measurement capabilities. FPI technology has also created a basis for various hyperspectral imaging instruments, ranging from nanosatellites, environmental sensing and precision agriculture with UAVs to instruments for skin cancer detection. Until now, these application demonstrations have been mostly realized with piezo-actuated FPIs fabricated by non-monolithical assembly method, suitable for achieving very large optical apertures and with capacity to small-to-medium volumes; however large-volume production of MEMS manufacturing supports the potential for emerging spectral imaging applications also in large-volume applications, such as in consumer/mobile products. Previously reported optical apertures of MEMS FPIs in the visible range have been up to 2 mm in size; this paper presents the design, successful fabrication and characterization of MEMS FPIs for central wavelengths of λ = 500 nm and λ = 650 nm with optical apertures up to 4 mm in diameter. The mirror membranes of the FPI structures consist of ALD (atomic layer deposited) TiO2-Al2O3 λ/4- thin film Bragg reflectors, with the air gap formed by sacrificial polymer etching in O2 plasma. The entire fabrication process is conducted below 150 °C, which makes it possible to monolithically integrate the filter structures on other ICdevices such as detectors. The realized MEMS devices are aimed for nanosatellite space application as breadboard hyperspectral imager demonstrators.

  11. Biomonitoring of perfluorinated compounds in a drop of blood.

    PubMed

    Mao, Pan; Wang, Daojing

    2015-06-02

    Biomonitoring of pollutants and their metabolites and derivatives using biofluids provides new opportunities for spatiotemporal assessment of human risks to environmental exposures. Perfluorinated compounds (PFCs) have been used widely in industry and pose significant environmental concerns due to their stability and bioaccumulation in humans and animals. However, current methods for extraction and measurement of PFCs require relatively large volumes (over one hundred microliters) of blood samples, and therefore, are not suitable for frequent blood sampling and longitudinal biomonitoring of PFCs. We have developed a new microassay, enabled by our silicon microfluidic chip platform, for analyzing PFCs in small volumes (less than five microliters) of blood. Our assay integrates on-chip solid-phase extraction (SPE) with online nanoflow liquid chromatography-electrospray ionization-mass spectrometry (nanoLC-ESI-MS) detection. We demonstrated high sample recovery, excellent interday and intraday accuracy and precision, and a limit of detection down to 50 femtogram of PFCs, in one microliter of human plasma. We validated our assay performance using pooled human plasma and NIST SRM 1950 samples. Our microfluidic chip-based assay may enable frequent longitudinal biomonitoring of PFCs and other environmental toxins using a finger prick of blood, thereby providing new insights into their bioaccumulation, bioavailability, and toxicity.

  12. On-Chip Magnetic Bead Manipulation and Detection Using a Magnetoresistive Sensor-Based Micro-Chip: Design Considerations and Experimental Characterization

    PubMed Central

    Gooneratne, Chinthaka P.; Kodzius, Rimantas; Li, Fuquan; Foulds, Ian G.; Kosel, Jürgen

    2016-01-01

    The remarkable advantages micro-chip platforms offer over cumbersome, time-consuming equipment currently in use for bio-analysis are well documented. In this research, a micro-chip that includes a unique magnetic actuator (MA) for the manipulation of superparamagnetic beads (SPBs), and a magnetoresistive sensor for the detection of SPBs is presented. A design methodology, which takes into account the magnetic volume of SPBs, diffusion and heat transfer phenomena, is presented with the aid of numerical analysis to optimize the parameters of the MA. The MA was employed as a magnetic flux generator and experimental analysis with commercially available COMPEL™ and Dynabeads® demonstrated the ability of the MA to precisely transport a small number of SPBs over long distances and concentrate SPBs to a sensing site for detection. Moreover, the velocities of COMPEL™ and Dynabead® SPBs were correlated to their magnetic volumes and were in good agreement with numerical model predictions. We found that 2.8 μm Dynabeads® travel faster, and can be attracted to a magnetic source from a longer distance, than 6.2 μm COMPEL™ beads at magnetic flux magnitudes of less than 10 mT. The micro-chip system could easily be integrated with electronic circuitry and microfluidic functions, paving the way for an on-chip biomolecule quantification device. PMID:27571084

  13. On-Chip Magnetic Bead Manipulation and Detection Using a Magnetoresistive Sensor-Based Micro-Chip: Design Considerations and Experimental Characterization.

    PubMed

    Gooneratne, Chinthaka P; Kodzius, Rimantas; Li, Fuquan; Foulds, Ian G; Kosel, Jürgen

    2016-08-26

    The remarkable advantages micro-chip platforms offer over cumbersome, time-consuming equipment currently in use for bio-analysis are well documented. In this research, a micro-chip that includes a unique magnetic actuator (MA) for the manipulation of superparamagnetic beads (SPBs), and a magnetoresistive sensor for the detection of SPBs is presented. A design methodology, which takes into account the magnetic volume of SPBs, diffusion and heat transfer phenomena, is presented with the aid of numerical analysis to optimize the parameters of the MA. The MA was employed as a magnetic flux generator and experimental analysis with commercially available COMPEL™ and Dynabeads(®) demonstrated the ability of the MA to precisely transport a small number of SPBs over long distances and concentrate SPBs to a sensing site for detection. Moreover, the velocities of COMPEL™ and Dynabead(®) SPBs were correlated to their magnetic volumes and were in good agreement with numerical model predictions. We found that 2.8 μm Dynabeads(®) travel faster, and can be attracted to a magnetic source from a longer distance, than 6.2 μm COMPEL™ beads at magnetic flux magnitudes of less than 10 mT. The micro-chip system could easily be integrated with electronic circuitry and microfluidic functions, paving the way for an on-chip biomolecule quantification device.

  14. High efficiency microfluidic beta detector for pharmacokinetic studies in small animals

    NASA Astrophysics Data System (ADS)

    Convert, Laurence; Girard-Baril, Frédérique; Renaudin, Alan; Grondin, Étienne; Jaouad, Abdelatif; Aimez, Vincent; Charette, Paul; Lecomte, Roger

    2011-10-01

    New radiotracers are continuously being developed to improve diagnostic efficiency using Single Photon Emission Computed Tomography (SPECT) or Positron Emission Tomography (PET). The characterization of their pharmacokinetics requires blood radioactivity monitoring over time during the scan and is very challenging in small animals because of the low volume of blood available. In this work, a prototype microfluidic blood counter made of a microchannel atop a silicon substrate containing PIN photodiodes is proposed to improve beta detection efficiency in a small volume by eliminating unnecessary interfaces between fluid and detector. A flat rectangular-shaped epoxy channel, 36 μm×1.26 mm cross section and 31.5 mm in length, was microfabricated over a die containing an array of 2×2 mm 2 PIN photodiodes, leaving only a few micrometers of epoxy floor layer between the fluid and the photodiode sensitive surface. This geometry leads to a quasi 2D source, optimizing geometrical detection efficiency that was estimated at 41% using solid angle calculation. CV- IV measurements were made at each fabrication step to confirm that the microchannel components had no significant effects on the diodes' electrical characteristics. The chip was wire-bonded to a PCB and connected to charge sensitive preamplifier and amplifier modules for pulse shaping. Energy spectra recorded for different isotopes showed continuous beta distribution for PET isotopes and monoenergetic conversion electron peaks for 99mTc. Absolute sensitivity was determined for the most popular PET and SPECT radioisotopes and ranged from 26% to 33% for PET tracers ( 18F, 13N, 11C, 68Ga) and more than 2% for 99mTc. Input functions were successfully simulated with 18F, confirming the setup's suitability for pharmacokinetic modeling of PET and SPECT radiotracers in animal experiments. By using standard materials and procedures, the fabrication process is well suited to on-chip microfluidic functionality, allowing full characterization of new radiotracers.

  15. Antarctic icebergs distributions 1992-2014

    NASA Astrophysics Data System (ADS)

    Tournadre, J.; Bouhier, N.; Girard-Ardhuin, F.; Rémy, F.

    2016-01-01

    Basal melting of floating ice shelves and iceberg calving constitute the two almost equal paths of freshwater flux between the Antarctic ice cap and the Southern Ocean. The largest icebergs (>100 km2) transport most of the ice volume but their basal melting is small compared to their breaking into smaller icebergs that constitute thus the major vector of freshwater. The archives of nine altimeters have been processed to create a database of small icebergs (<8 km2) within open water containing the positions, sizes, and volumes spanning the 1992-2014 period. The intercalibrated monthly ice volumes from the different altimeters have been merged in a homogeneous 23 year climatology. The iceberg size distribution, covering the 0.1-10,000 km2 range, estimated by combining small and large icebergs size measurements follows well a power law of slope -1.52 ± 0.32 close to the -3/2 laws observed and modeled for brittle fragmentation. The global volume of ice and its distribution between the ocean basins present a very strong interannual variability only partially explained by the number of large icebergs. Indeed, vast zones of the Southern Ocean free of large icebergs are largely populated by small iceberg drifting over thousands of kilometers. The correlation between the global small and large icebergs volumes shows that small icebergs are mainly generated by large ones breaking. Drifting and trapping by sea ice can transport small icebergs for long period and distances. Small icebergs act as an ice diffuse process along large icebergs trajectories while sea ice trapping acts as a buffer delaying melting.

  16. 40 CFR 86.1838-01 - Small volume manufacturer certification procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... paragraph (c)(2). (i) Small volume in-use verification test vehicles may be procured from customers or may... miles, a manufacturer may demonstrate to the satisfaction of the Agency that, based on owner survey data...

  17. New intravascular flow sensor using fiber optics

    NASA Astrophysics Data System (ADS)

    Stenow, Erik N. D.

    1994-12-01

    A new sensor using fiber optics is suggested for blood flow measurements in small vessels. The sensor principle and a first evaluation on a flow model are presented. The new sensor uses small CO2 gas bubbles as flow markers for optical detection. When the bubbles pass an optical window, light emitted from one fiber is reflected and scattered into another fiber. The sensor has been proven to work in a 3 mm flow model using two 110 micrometers optical fibers and a 100 micrometers steel capillary inserted into a 1 mm guide wire. The evaluation of a sensor archetype shows that the new sensor provides a promising method for intravascular blood flow measurement in small vessels. The linearity for steady state flow is studied in the flow interval 30 - 130 ml/min. comparison with ultrasound Doppler flowmetry was performed for pulsatile flow in the interval 25 - 125 ml/min. with a pulse length between 0.5 and 2 s. The use of intravascular administered CO2 in small volumes is harmless because the gas is rapidly dissolved in whole blood.

  18. Effects of horizontal plyometric training volume on soccer players' performance.

    PubMed

    Yanci, Javier; Los Arcos, Asier; Camara, Jesús; Castillo, Daniel; García, Alberto; Castagna, Carlo

    2016-01-01

    The aim of this study was to examine the dose response effect of strength and conditioning programmes, involving horizontally oriented plyometric exercises, on relevant soccer performance variables. Sixteen soccer players were randomly allocated to two 6-week plyometric training groups (G1 and G2) differing by imposed (twice a week) training volume. Post-training G1 (4.13%; d = 0.43) and G2 (2.45%; d = 0.53) moderately improved their horizontal countermovement jump performance. Significant between-group differences (p < 0.01) in the vertical countermovement jump for force production time (T2) were detected post-training. No significant and practical (p > 0.05, d = trivial or small) post-training improvements in sprint, change of direction ability (CODA) and horizontal arm swing countermovement jump were reported in either group. Horizontal plyometric training was effective in promoting improvement in injury prevention variables. Doubling the volume of a horizontal plyometric training protocol was shown to have no additional effect over functional aspects of soccer players' performance.

  19. Estimating stem volume and biomass of Pinus koraiensis using LiDAR data.

    PubMed

    Kwak, Doo-Ahn; Lee, Woo-Kyun; Cho, Hyun-Kook; Lee, Seung-Ho; Son, Yowhan; Kafatos, Menas; Kim, So-Ra

    2010-07-01

    The objective of this study was to estimate the stem volume and biomass of individual trees using the crown geometric volume (CGV), which was extracted from small-footprint light detection and ranging (LiDAR) data. Attempts were made to analyze the stem volume and biomass of Korean Pine stands (Pinus koraiensis Sieb. et Zucc.) for three classes of tree density: low (240 N/ha), medium (370 N/ha), and high (1,340 N/ha). To delineate individual trees, extended maxima transformation and watershed segmentation of image processing methods were applied, as in one of our previous studies. As the next step, the crown base height (CBH) of individual trees has to be determined; information for this was found in the LiDAR point cloud data using k-means clustering. The LiDAR-derived CGV and stem volume can be estimated on the basis of the proportional relationship between the CGV and stem volume. As a result, low tree-density plots had the best performance for LiDAR-derived CBH, CGV, and stem volume (R (2) = 0.67, 0.57, and 0.68, respectively) and accuracy was lowest for high tree-density plots (R (2) = 0.48, 0.36, and 0.44, respectively). In the case of medium tree-density plots accuracy was R (2) = 0.51, 0.52, and 0.62, respectively. The LiDAR-derived stem biomass can be predicted from the stem volume using the wood basic density of coniferous trees (0.48 g/cm(3)), and the LiDAR-derived above-ground biomass can then be estimated from the stem volume using the biomass conversion and expansion factors (BCEF, 1.29) proposed by the Korea Forest Research Institute (KFRI).

  20. Modulation infrared thermometry of caloric effects at up to kHz frequencies

    NASA Astrophysics Data System (ADS)

    Döntgen, Jago; Rudolph, Jörg; Waske, Anja; Hägele, Daniel

    2018-03-01

    We present a novel non-contact method for the direct measurement of caloric effects in low volume samples. The adiabatic temperature change ΔT of a magnetocaloric sample is very sensitively determined from thermal radiation. Rapid modulation of ΔT is induced by an oscillating external magnetic field. Detection of thermal radiation with a mercury-cadmium-telluride detector allows for measurements at field frequencies exceeding 1 kHz. In contrast to thermoacoustic methods, our method can be employed in vacuum which enhances adiabatic conditions especially in the case of small volume samples. Systematic measurements of the magnetocaloric effect as a function of temperature, magnetic field amplitude, and modulation frequency give a detailed picture of the thermal behavior of the sample. Highly sensitive measurements of the magnetocaloric effect are demonstrated on a 2 mm thick sample of gadolinium and a 60 μm thick Fe80B12Nb8 ribbon.

  1. Applications of thermal remote sensing to detailed ground water studies

    NASA Technical Reports Server (NTRS)

    Souto-Maior, J.

    1973-01-01

    Three possible applications of thermal (8-14 microns) remote sensing to detailed hydrogeologic studies are discussed in this paper: (1) the direct detection of seeps and springs, (2) the indirect evaluation of shallow ground water flow through its thermal effects on the land surface, and (3) the indirect location of small volumes of ground water inflow into surface water bodies. An investigation carried out with this purpose in an area containing a complex shallow ground water flow system indicates that the interpretation of the thermal imageries is complicated by many factors, among which the most important are: (1) altitude, angle of view, and thermal-spatial resolution of the sensor; (2) vegetation type, density, and vigor; (3) topography; (4) climatological and micrometeorological effects; (5) variation in soil type and soil moisture; (6) variation in volume and temperature of ground water inflow; (7) the hydraulic characteristics of the receiving water body, and (8) the presence of decaying organic material.

  2. An inexpensive and portable microvolumeter for rapid evaluation of biological samples.

    PubMed

    Douglass, John K; Wcislo, William T

    2010-08-01

    We describe an improved microvolumeter (MVM) for rapidly measuring volumes of small biological samples, including live zooplankton, embryos, and small animals and organs. Portability and low cost make this instrument suitable for widespread use, including at remote field sites. Beginning with Archimedes' principle, which states that immersing an arbitrarily shaped sample in a fluid-filled container displaces an equivalent volume, we identified procedures that maximize measurement accuracy and repeatability across a broad range of absolute volumes. Crucial steps include matching the overall configuration to the size of the sample, using reflected light to monitor fluid levels precisely, and accounting for evaporation during measurements. The resulting precision is at least 100 times higher than in previous displacement-based methods. Volumes are obtained much faster than by traditional histological or confocal methods and without shrinkage artifacts due to fixation or dehydration. Calibrations using volume standards confirmed accurate measurements of volumes as small as 0.06 microL. We validated the feasibility of evaluating soft-tissue samples by comparing volumes of freshly dissected ant brains measured with the MVM and by confocal reconstruction.

  3. The Different Volume Effects of Small-Bowel Toxicity During Pelvic Irradiation Between Gynecologic Patients With and Without Abdominal Surgery: A Prospective Study With Computed Tomography-Based Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, E.-Y.; Graduate Institute of Clinical Medical Sciences, Chang Gung University College of Medicine, Kaohsiung, Taiwan; School of Traditional Chinese Medicine, Chang Gung University College of Medicine, Kaohsiung, Taiwan

    Purpose: To evaluate the effect of abdominal surgery on the volume effects of small-bowel toxicity during whole-pelvic irradiation in patients with gynecologic malignancies. Methods and Materials: From May 2003 through November 2006, 80 gynecologic patients without (Group I) or with (Group II) prior abdominal surgery were analyzed. We used a computed tomography (CT) planning system to measure the small-bowel volume and dosimetry. We acquired the range of small-bowel volume in 10% (V10) to 100% (V100) of dose, at 10% intervals. The onset and grade of diarrhea during whole-pelvic irradiation were recorded as small-bowel toxicity up to 39.6 Gy in 22more » fractions. Results: The volume effect of Grade 2-3 diarrhea existed from V10 to V100 in Group I patients and from V60 to V100 in Group II patients on univariate analyses. The V40 of Group I and the V100 of Group II achieved most statistical significance. The mean V40 was 281 {+-} 27 cm{sup 3} and 489 {+-} 34 cm{sup 3} (p < 0.001) in Group I patients with Grade 0-1 and Grade 2-3 diarrhea, respectively. The corresponding mean V100 of Group II patients was 56 {+-} 14 cm{sup 3} and 132 {+-} 19 cm{sup 3} (p = 0.003). Multivariate analyses revealed that V40 (p = 0.001) and V100 (p = 0.027) were independent factors for the development of Grade 2-3 diarrhea in Groups I and II, respectively. Conclusions: Gynecologic patients without and with abdominal surgery have different volume effects on small-bowel toxicity during whole-pelvic irradiation. Low-dose volume can be used as a predictive index of Grade 2 or greater diarrhea in patients without abdominal surgery. Full-dose volume is more important than low-dose volume for Grade 2 or greater diarrhea in patients with abdominal surgery.« less

  4. Measuring pedestrian volumes and conflicts. Volume 1, Pedestrian volume sampling

    DOT National Transportation Integrated Search

    1987-12-01

    This final report presents the findings, conclusions, and recommendations of the study conducted to develop a model to predict pedestrian volumes using small sampling schemes. This research produced four pedestrian volume prediction models (i.e., 1-,...

  5. Evaluation of the DIRAMIC system for detection of urinary tract infections and for Escherichia coli identification.

    PubMed

    Travieso Ruiz, Fernando; Roura Carmona, Gloria; Romay Penabad, Cheyla; Contreras Alarcón, Rolando

    2004-01-01

    The use of the DIRAMIC system for the detection of urinary tract infections (UTI) and the possibility to identify Escherichia coli in the same culture media was evaluated. The results from DIRAMIC detection system were compared to counts of colony forming units per milliliter (CFU/ml) of urine inoculated in CLED Medium; 884 urine specimens were processed taking > or =10(4) CFU/ml as criteria of positive urine culture counts. For E. coli identification, substrates for the determination of beta-glucuronidase and tryptophanase were incorporated to the culture medium and named DETID-Ec. Outputs were compared to those from API RAPIDEC-ur strips. The DIRAMIC system can detect UTI, with a sensitivity and specificity of 82.25 and 94.49%, respectively. It was possible to identify E. coli during detection with 87.50% of sensitivity and 95.96% of specificity. The small volumes of culture medium used in the DIRAMIC system as well as the short times for the detection make the system a rapid and economical method for screening UTI. Furthermore, by using DETID-Ec culture medium the time and the number of biochemical tests necessary for the E. coli identification are lowered.

  6. Particle detection systems and methods

    DOEpatents

    Morris, Christopher L.; Makela, Mark F.

    2010-05-11

    Techniques, apparatus and systems for detecting particles such as muons and neutrons. In one implementation, a particle detection system employs a plurality of drift cells, which can be for example sealed gas-filled drift tubes, arranged on sides of a volume to be scanned to track incoming and outgoing charged particles, such as cosmic ray-produced muons. The drift cells can include a neutron sensitive medium to enable concurrent counting of neutrons. The system can selectively detect devices or materials, such as iron, lead, gold, uranium, plutonium, and/or tungsten, occupying the volume from multiple scattering of the charged particles passing through the volume and can concurrently detect any unshielded neutron sources occupying the volume from neutrons emitted therefrom. If necessary, the drift cells can be used to also detect gamma rays. The system can be employed to inspect occupied vehicles at border crossings for nuclear threat objects.

  7. Remote visual detection of impacts on the lunar surface

    NASA Technical Reports Server (NTRS)

    Melosh, H. Jay; Artemjeva, N. A.; Golub, A. P.; Nemchinov, I. V.; Shuvalov, V. V.; Trubetskaya, I. A.

    1993-01-01

    We propose a novel method of remotely observing impacts on the airless Moon that may extend the present data base on meteoroids down to 1 m in diameter. Meteorites or comets of radius approximately 1-100 m are burnt away or dispersed in the atmospheres of the Earth and Venus. However, when such objects strike the Moon they deposit their energy in a small initial volume, forming a plasma plume whose visible and infrared radiation may be visible from the Earth. We consider impacts of model SiO2 projectiles on the surface of an SiO2 model Moon.

  8. Nano/microfluidics for diagnosis of infectious diseases in developing countries

    PubMed Central

    Lee, Won Gu; Kim, Yun-Gon; Chung, Bong Geun; Demirci, Utkan; Khademhosseini, Ali

    2010-01-01

    Nano/microfluidic technologies are emerging as powerful enabling tools for diagnosis and monitoring of infectious diseases in both developed and developing countries. Miniaturized nano/microfluidic platforms that precisely manipulate small fluid volumes can be used to enable medical diagnosis in a more rapid and accurate manner. In particular, these nano/microfluidic diagnostic technologies are potentially applicable to global health applications, because they are disposable, inexpensive, portable, and easy-to-use for detection of infectious diseases. In this paper, we review recent developments in nano/microfluidic technologies for clinical point-of-care applications at resource-limited settings in developing countries. PMID:19954755

  9. MTO-like reference mask modeling for advanced inverse lithography technology patterns

    NASA Astrophysics Data System (ADS)

    Park, Jongju; Moon, Jongin; Son, Suein; Chung, Donghoon; Kim, Byung-Gook; Jeon, Chan-Uk; LoPresti, Patrick; Xue, Shan; Wang, Sonny; Broadbent, Bill; Kim, Soonho; Hur, Jiuk; Choo, Min

    2017-07-01

    Advanced Inverse Lithography Technology (ILT) can result in mask post-OPC databases with very small address units, all-angle figures, and very high vertex counts. This creates mask inspection issues for existing mask inspection database rendering. These issues include: large data volumes, low transfer rate, long data preparation times, slow inspection throughput, and marginal rendering accuracy leading to high false detections. This paper demonstrates the application of a new rendering method including a new OASIS-like mask inspection format, new high-speed rendering algorithms, and related hardware to meet the inspection challenges posed by Advanced ILT masks.

  10. A Continuation of Base-Line Studies for Environmentally Monitoring Space Transportation System (STS) at John F. Kennedy Space Center. Volume 1; Terrestrial Community Analysis

    NASA Technical Reports Server (NTRS)

    Stout, I. J.

    1979-01-01

    Vegetation and small mammal populations in or around the Merritt Island area were studied. Thirty sites were selected from plant communities which were relatively free of logging, grazing, and clearing operations. The vegetative analysis was designed to yield a quantitative description and ecological explanation of the major types of upland vegetation in order to determine the possible future effects of NASA space activities on them. Changes in the relative abundance of small mammal populations, species diversity, standing crop biomass, reproductive activity, and other demographic features were documented in order to gather sufficient information on these populations so that it would be possible to detect even the smaller nonnatural behavior changes in the mammals which might be attributable to NASA space activities.

  11. Mechanistic Fluid Transport Model to Estimate Gastrointestinal Fluid Volume and Its Dynamic Change Over Time.

    PubMed

    Yu, Alex; Jackson, Trachette; Tsume, Yasuhiro; Koenigsknecht, Mark; Wysocki, Jeffrey; Marciani, Luca; Amidon, Gordon L; Frances, Ann; Baker, Jason R; Hasler, William; Wen, Bo; Pai, Amit; Sun, Duxin

    2017-11-01

    Gastrointestinal (GI) fluid volume and its dynamic change are integral to study drug disintegration, dissolution, transit, and absorption. However, key questions regarding the local volume and its absorption, secretion, and transit remain unanswered. The dynamic fluid compartment absorption and transit (DFCAT) model is proposed to estimate in vivo GI volume and GI fluid transport based on magnetic resonance imaging (MRI) quantified fluid volume. The model was validated using GI local concentration of phenol red in human GI tract, which was directly measured by human GI intubation study after oral dosing of non-absorbable phenol red. The measured local GI concentration of phenol red ranged from 0.05 to 168 μg/mL (stomach), to 563 μg/mL (duodenum), to 202 μg/mL (proximal jejunum), and to 478 μg/mL (distal jejunum). The DFCAT model characterized observed MRI fluid volume and its dynamic changes from 275 to 46.5 mL in stomach (from 0 to 30 min) with mucus layer volume of 40 mL. The volumes of the 30 small intestine compartments were characterized by a max of 14.98 mL to a min of 0.26 mL (0-120 min) and a mucus layer volume of 5 mL per compartment. Regional fluid volumes over 0 to 120 min ranged from 5.6 to 20.38 mL in the proximal small intestine, 36.4 to 44.08 mL in distal small intestine, and from 42 to 64.46 mL in total small intestine. The DFCAT model can be applied to predict drug dissolution and absorption in the human GI tract with future improvements.

  12. Volumetric analysis of the hypothalamus, amygdala and hippocampus in non-suicidal and suicidal mood disorder patients--a post-mortem study.

    PubMed

    Bielau, Hendrik; Brisch, Ralf; Gos, Tomasz; Dobrowolny, Henrik; Baumann, Bruno; Mawrin, Christian; Kreutzmann, Peter; Bernstein, Hans-Gert; Bogerts, Bernhard; Steiner, Johann

    2013-11-01

    In recent years, the hypothalamus, amygdala and hippocampus have attracted increased interest with regard to the effects of stress on neurobiological systems in individuals with depression and suicidal behaviour. A large body of evidence indicates that these subcortical regions are involved in the pathogenetic mechanisms of mood disorders and suicide. The current neuroimaging techniques inadequately resolve the structural components of small and complex brain structures. In previous studies, our group was able to demonstrate a structural and neuronal pathology in mood disorders. However, the impact of suicide remains unclear. In the current study we used volumetric measurements of serial postmortem sections with combined Nissl-myelin staining to investigate the hypothalamus, amygdala and hippocampus in suicide victims with mood disorders (n = 11), non-suicidal mood disorder patients (n = 9) and control subjects (n = 23). Comparisons between the groups by using an ANCOVA showed a significant overall difference for the hypothalamus (p = 0.001) with reduced volumes in non-suicidal patients compared to suicide victims (p = 0.018) and controls (p = 0.006). To our surprise, the volumes between the suicide victims and controls did not differ significantly. For the amygdala and hippocampus no volume changes between the groups could be detected (all p values were n. s.). In conclusion our data suggest a structural hypothalamic pathology in non-suicidal mood disorder patients. The detected differences between suicidal and non-suicidal patients suggest that suicidal performances might be related to the degree of structural deficits.

  13. Source tracking of leaky sewers: a novel approach combining fecal indicators in water and sediments.

    PubMed

    Guérineau, Hélène; Dorner, Sarah; Carrière, Annie; McQuaid, Natasha; Sauvé, Sébastien; Aboulfadl, Khadija; Hajj-Mohamad, Mariam; Prévost, Michèle

    2014-07-01

    In highly urbanized areas, surface water and groundwater are particularly vulnerable to sewer exfiltration. In this study, as an alternative to Microbial Source Tracking (MST) methods, we propose a new method combining microbial and chemical fecal indicators (Escherichia coli (E. coli)) and wastewater micropollutants (WWMPs) analysis both in water and sediment samples and under different meteorological conditions. To illustrate the use of this method, wastewater exfiltration and subsequent infiltration were identified and quantified by a three-year field study in an urban canal. The gradients of concentrations observed suggest that several sources of fecal contamination of varying intensity may be present along the canal, including feces from resident animal populations, contaminated surface run-off along the banks and under bridge crossings, release from contaminated banks, entrainment of contaminated sediments, and most importantly sewage exfiltration. Calculated exfiltration-infiltration volumes varied between 0.6 and 15.7 m(3)/d per kilometer during dry weather, and between 1.1 and 19.5 m(3)/d per kilometer during wet weather. WWMPs were mainly diluted and degraded below detection limits in water. E. coli remains the best exfiltration indicator given a large volume of dilution and a high abundance in the wastewater source. WWMPs are effective for detecting cumulated contamination in sediments from a small volume source and are particularly important because E. coli on its own does not allow source tracking. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Preliminary Measures of Instructor Learning in Teaching Junctional Tourniquet Users.

    PubMed

    Kragh, John F; Aden, James K; Shackelford, Stacy; Dubick, Michael A

    2016-01-01

    The objective of the present study was to assess the effect of instructor learning on student performance in use of junctional tourniquets. From a convenience sample of data available after another study, we used a manikin for assessment of control of bleeding from a right groin gunshot wound. Blood loss was measured by the instructor while training users. The data set represented a group of 30 persons taught one at a time. The first measure was a plot of mean blood loss volumes for the sequential users. The second measure was a plot of the cumulative sum (CUSUM) of mean blood loss (BL) volumes for users. Mean blood loss trended down as the instructor gained experience with each newly instructed user. User performance continually improved as the instructor gained more experience with teaching. No plateau effect was observed within the 30 users. The CUSUM plot illustrated a turning point or cusp at the seventh user. The prior portion of the plot (users 1-7) had the greatest improvement; performance did not improve as much thereafter. The improvement after the seventh user was the only change detected in the instructor's trend of performance. The instructor's teaching experience appeared to directly affect user performance; in a model of junctional hemorrhage, the volume of blood loss from the manikin during junctional tourniquet placement was a useful metric of instructor learning. The CUSUM technique detected a small but meaningful change in trend where the instructor learning curve was greatest while working with the first seven users. 2016.

  15. Toward high-resolution NMR spectroscopy of microscopic liquid samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butler, Mark C.; Mehta, Hardeep S.; Chen, Ying

    A longstanding limitation of high-resolution NMR spectroscopy is the requirement for samples to have macroscopic dimensions. Commercial probes, for example, are designed for volumes of at least 5 mL, in spite of decades of work directed toward the goal of miniaturization. Progress in miniaturizing inductive detectors has been limited by a perceived need to meet two technical requirements: (1) minimal separation between the sample and the detector, which is essential for sensitivity, and (2) near-perfect magnetic-field homogeneity at the sample, which is typically needed for spectral resolution. The first of these requirements is real, but the second can be relaxed,more » as we demonstrate here. By using pulse sequences that yield high-resolution spectra in an inhomogeneous field, we eliminate the need for near-perfect field homogeneity and the accompanying requirement for susceptibility matching of microfabricated detector components. With this requirement removed, typical imperfections in microfabricated components can be tolerated, and detector dimensions can be matched to those of the sample, even for samples of volume << 5 uL. Pulse sequences that are robust to field inhomogeneity thus enable small-volume detection with optimal sensitivity. We illustrate the potential of this approach to miniaturization by presenting spectra acquired with a flat-wire detector that can easily be scaled to subnanoliter volumes. In particular, we report high-resolution NMR spectroscopy of an alanine sample of volume 500 pL.« less

  16. A Full Automatic Device for Sampling Small Solution Volumes in Photometric Titration Procedure Based on Multicommuted Flow System

    PubMed Central

    Borges, Sivanildo S.; Vieira, Gláucia P.; Reis, Boaventura F.

    2007-01-01

    In this work, an automatic device to deliver titrant solution into a titration chamber with the ability to determine the dispensed volume of solution, with good precision independent of both elapsed time and flow rate, is proposed. A glass tube maintained at the vertical position was employed as a container for the titrant solution. Electronic devices were coupled to the glass tube in order to control its filling with titrant solution, as well as the stepwise solution delivering into the titration chamber. The detection of the titration end point was performed employing a photometer designed using a green LED (λ=545 nm) and a phototransistor. The titration flow system comprised three-way solenoid valves, which were assembled to allow that the steps comprising the solution container loading and the titration run were carried out automatically. The device for the solution volume determination was designed employing an infrared LED (λ=930 nm) and a photodiode. When solution volume delivered from proposed device was within the range of 5 to 105 μl, a linear relationship (R = 0.999) between the delivered volumes and the generated potential difference was achieved. The usefulness of the proposed device was proved performing photometric titration of hydrochloric acid solution with a standardized sodium hydroxide solution and using phenolphthalein as an external indicator. The achieved results presented relative standard deviation of 1.5%. PMID:18317510

  17. A prospective pilot study measuring muscle volumetric change in amyotrophic lateral sclerosis.

    PubMed

    Jenkins, Thomas M; Burness, Christine; Connolly, Daniel J; Rao, D Ganesh; Hoggard, Nigel; Mawson, Susan; McDermott, Christopher J; Wilkinson, Iain D; Shaw, Pamela J

    2013-09-01

    Our objective was to investigate the potential of muscle volume, measured with magnetic resonance (MR), as a biomarker to quantify disease progression in patients with amyotrophic lateral sclerosis (ALS). In this longitudinal pilot study, we first sought to determine the stability of volumetric muscle MR measurements in 11 control subjects at two time-points. We assessed feasibility of detecting atrophy in four patients with ALS, followed at three-month intervals for 12 months. Muscle power and MR volume were measured in thenar eminence (TEm), first dorsal interosseous (1DIO), tibialis anterior (TA) and tongue. Changes over time were assessed using linear regression models and t-tests. Results demonstrated that, in controls, no volumetric MR changes were seen (mean volume variation in all muscles < 5%, p > 0.1). In patients, between-subject heterogeneity was identified. Trends for volume loss were found in TEm (mean, - 26.84%, p = 0.056) and TA (- 8.29%, p = 0.077), but not in 1DIO (- 18.47%, p = 0.121) or tongue (< 5%, p = 0.367). In conclusion, volumetric muscle MR appears a stable measure in controls, and progressive volume loss was demonstrable in individuals with ALS in whom clinical weakness progressed. In this small study, subclinical atrophy was not demonstrable using muscle MR. Clinico-radiological discordance between muscle weakness and MR atrophy could reflect a contribution of upper motor neuron pathology.

  18. Interaction between BDNF rs6265 Met allele and low family cohesion is associated with smaller left hippocampal volume in pediatric bipolar disorder.

    PubMed

    Zeni, Cristian Patrick; Mwangi, Benson; Cao, Bo; Hasan, Khader M; Walss-Bass, Consuelo; Zunta-Soares, Giovana; Soares, Jair C

    2016-01-01

    Genetic and environmental factors are implicated in the onset and evolution of pediatric bipolar disorder, and may be associated to structural brain abnormalities. The aim of our study was to assess the impact of the interaction between the Brain-Derived Neurotrophic Factor (BDNF) rs6265 polymorphism and family functioning on hippocampal volumes of children and adolescents with bipolar disorder, and typically-developing controls. We evaluated the family functioning cohesion subscale using the Family Environment Scale-Revised, genotyped the BDNF rs6265 polymorphism, and performed structural brain imaging in 29 children and adolescents with bipolar disorder, and 22 healthy controls. We did not find significant differences between patients with BD or controls in left or right hippocampus volume (p=0.44, and p=0.71, respectively). However, we detected a significant interaction between low scores on the cohesion subscale and the presence of the Met allele at BNDF on left hippocampal volume of patients with bipolar disorder (F=3.4, p=0.043). None of the factors independently (BDNF Val66Met, cohesion scores) was significantly associated with hippocampal volume differences. small sample size, cross-sectional study. These results may lead to a better understanding of the impact of the interaction between genes and environment factors on brain structures associated to bipolar disorder and its manifestations. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. An efficient biosensor made of an electromagnetic trap and a magneto-resistive sensor.

    PubMed

    Li, Fuquan; Kosel, Jürgen

    2014-09-15

    Magneto-resistive biosensors have been found to be useful because of their high sensitivity, low cost, small size, and direct electrical output. They use super-paramagnetic beads to label a biological target and detect it via sensing the stray field. In this paper, we report a new setup for magnetic biosensors, replacing the conventional "sandwich" concept with an electromagnetic trap. We demonstrate the capability of the biosensor in the detection of E. coli. The trap is formed by a current-carrying microwire that attracts the magnetic beads into a sensing space on top of a tunnel magneto-resistive sensor. The sensor signal depends on the number of beads in the sensing space, which depends on the size of the beads. This enables the detection of biological targets, because such targets increase the volume of the beads. Experiments were carried out with a 6 µm wide microwire, which attracted the magnetic beads from a distance of 60 μm, when a current of 30 mA was applied. A sensing space of 30 µm in length and 6 µm in width was defined by the magnetic sensor. The results showed that individual E. coli bacterium inside the sensing space could be detected using super-paramagnetic beads that are 2.8 µm in diameter. The electromagnetic trap setup greatly simplifies the device and reduces the detection process to two steps: (i) mixing the bacteria with magnetic beads and (ii) applying the sample solution to the sensor for measurement, which can be accomplished within about 30 min with a sample volume in the µl range. This setup also ensures that the biosensor can be cleaned easily and re-used immediately. The presented setup is readily integrated on chips via standard microfabrication techniques. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Integrated chemical/biochemical sample collection, pre-concentration, and analysis on a digital microfluidic lab-on-a-chip platform

    NASA Astrophysics Data System (ADS)

    Fair, Richard B.; Khlystov, A.; Srinivasan, Vijay; Pamula, Vamsee K.; Weaver, Kathryn N.

    2004-12-01

    An ideal on-site chemical/biochemical analysis system must be inexpensive, sensitive, fully automated and integrated, reliable, and compatible with a broad range of samples. The advent of digital microfluidic lab-on-a-chip (LoC) technology offers such a detection system due to the advantages in portability, reduction of the volumes of the sample and reagents, faster analysis times, increased automation, low power consumption, compatibility with mass manufacturing, and high throughput. We describe progress towards integrating sample collection onto a digital microfluidic LoC that is a component of a cascade impactor device. The sample collection is performed by impacting airborne particles directly onto the surface of the chip. After the collection phase, the surface of the chip is washed with a micro-droplet of solvent. The droplet will be digitally directed across the impaction surface, dissolving sample constituents. Because of the very small droplet volume used for extraction of the sample from a wide colection area, the resulting solution is realatively concentrated and the analytes can be detected after a very short sampling time (1 min) due to such pre-concentration. After the washing phase, the droplet is mixed with specific reagents that produce colored reaction products. The concentration of the analyte is quantitatively determined by measuring absorption at target wavelengths using a simple light emitting diode and photodiode setup. Specific applications include automatic measurements of major inorganic ions in aerosols, such as sulfate, nitrate and ammonium, with a time resolution of 1 min and a detection limit of 30 nm/m3. We have already demonstrated the detection and quantification of nitroaromatic explosives without integrating the sample collection. Other applications being developed include airborne bioagent detection.

  1. GMP Cryopreservation of Large Volumes of Cells for Regenerative Medicine: Active Control of the Freezing Process

    PubMed Central

    Massie, Isobel; Selden, Clare; Hodgson, Humphrey; Gibbons, Stephanie; Morris, G. John

    2014-01-01

    Cryopreservation protocols are increasingly required in regenerative medicine applications but must deliver functional products at clinical scale and comply with Good Manufacturing Process (GMP). While GMP cryopreservation is achievable on a small scale using a Stirling cryocooler-based controlled rate freezer (CRF) (EF600), successful large-scale GMP cryopreservation is more challenging due to heat transfer issues and control of ice nucleation, both complex events that impact success. We have developed a large-scale cryocooler-based CRF (VIA Freeze) that can process larger volumes and have evaluated it using alginate-encapsulated liver cell (HepG2) spheroids (ELS). It is anticipated that ELS will comprise the cellular component of a bioartificial liver and will be required in volumes of ∼2 L for clinical use. Sample temperatures and Stirling cryocooler power consumption was recorded throughout cooling runs for both small (500 μL) and large (200 mL) volume samples. ELS recoveries were assessed using viability (FDA/PI staining with image analysis), cell number (nuclei count), and function (protein secretion), along with cryoscanning electron microscopy and freeze substitution techniques to identify possible injury mechanisms. Slow cooling profiles were successfully applied to samples in both the EF600 and the VIA Freeze, and a number of cooling and warming profiles were evaluated. An optimized cooling protocol with a nonlinear cooling profile from ice nucleation to −60°C was implemented in both the EF600 and VIA Freeze. In the VIA Freeze the nucleation of ice is detected by the control software, allowing both noninvasive detection of the nucleation event for quality control purposes and the potential to modify the cooling profile following ice nucleation in an active manner. When processing 200 mL of ELS in the VIA Freeze—viabilities at 93.4%±7.4%, viable cell numbers at 14.3±1.7 million nuclei/mL alginate, and protein secretion at 10.5±1.7 μg/mL/24 h were obtained which, compared well with control ELS (viability −98.1%±0.9%; viable cell numbers −18.3±1.0 million nuclei/mL alginate; and protein secretion −18.7±1.8 μg/mL/24 h). Large volume GMP cryopreservation of ELS is possible with good functional recovery using the VIA Freeze and may also be applied to other regenerative medicine applications. PMID:24410575

  2. Pressure-jump small-angle x-ray scattering detected kinetics of staphylococcal nuclease folding.

    PubMed Central

    Woenckhaus, J; Köhling, R; Thiyagarajan, P; Littrell, K C; Seifert, S; Royer, C A; Winter, R

    2001-01-01

    The kinetics of chain disruption and collapse of staphylococcal nuclease after positive or negative pressure jumps was monitored by real-time small-angle x-ray scattering under pressure. We used this method to probe the overall conformation of the protein by measuring its radius of gyration and pair-distance-distribution function p(r) which are sensitive to the spatial extent and shape of the particle. At all pressures and temperatures tested, the relaxation profiles were well described by a single exponential function. No fast collapse was observed, indicating that the rate limiting step for chain collapse is the same as that for secondary and tertiary structure formation. Whereas refolding at low pressures occurred in a few seconds, at high pressures the relaxation was quite slow, approximately 1 h, due to a large positive activation volume for the rate-limiting step for chain collapse. A large increase in the system volume upon folding implies significant dehydration of the transition state and a high degree of similarity in terms of the packing density between the native and transition states in this system. This study of the time-dependence of the tertiary structure in pressure-induced folding/unfolding reactions demonstrates that novel information about the nature of protein folding transitions and transition states can be obtained from a combination of small-angle x-ray scattering using high intensity synchrotron radiation with the high pressure perturbation technique. PMID:11222312

  3. Cancer-cells on a chip for label-free optic detection of secreted molecules

    NASA Astrophysics Data System (ADS)

    Berthuy, Ophélie I.; Blum, Loïc. J.; Marquette, Christophe A.

    2015-05-01

    To unravel cell complexity, living-cell chips have been developed that allow delivery of experimental stimuli but also measurement of the resulting cellular responses. We have been developing a new concept for multiplexed detection of biomolecules secreted by different cancer cells. In the present report, we are making the proof of concept of cell small populations (from 1 to 100 cells) spotting, culture and secretion detection on a gold surface. For that purpose, antibodies and different cell lines were spotted using a piezoelectric spotter. In order to keep the cells in a hydrated environment during the robotized micropipetting and to address different cell lines on a single chip, a biocompatible alginate polymer was used. This approach enables the encapsulation of the cell in a very small volume (30 nL), directly on the substrate and permits a precise control of the number of cells in each alginate bead. After 24h of culture, the adherent cells are ready for surface plasmon resonance imaging (SPRi) experimentation. To enable the detection of secreted proteins, various antibodies are immobilized in an organized manner on a SPRi sensor and permitted the multiplex detection of different proteins secreted by the different cultured cell lines. Evidence of the real-time detection will be presented for Prostate Specific Antigen (PSA) and β-2-microglobulin (B2M) secreted by prostate cancer cells following induction by dihydrotestosterone (DHT). Different kinetics for the two secreted proteins were then demonstrated and precisely determined using the chip. There is no doubt that our chip will, in a near future, be applied to more multiplexed and complex biological secretion systems for which kinetic data are at the moment not reachable using standard cellular biology tools.

  4. Nanoparticle Enhancement Cascade for Sensitive Multiplex Measurements of Biomarkers in Complex Fluids with Surface Plasmon Resonance Imaging.

    PubMed

    Hendriks, Jan; Stojanovic, Ivan; Schasfoort, Richard B M; Saris, Daniël B F; Karperien, Marcel

    2018-06-05

    There is a large unmet need for reliable biomarker measurement systems for clinical application. Such systems should meet challenging requirements for large scale use, including a large dynamic detection range, multiplexing capacity, and both high specificity and sensitivity. More importantly, these requirements need to apply to complex biological samples, which require extensive quality control. In this paper, we present the development of an enhancement detection cascade for surface plasmon resonance imaging (SPRi). The cascade applies an antibody sandwich assay, followed by neutravidin and a gold nanoparticle enhancement for quantitative biomarker measurements in small volumes of complex fluids. We present a feasibility study both in simple buffers and in spiked equine synovial fluid with four cytokines, IL-1β, IL-6, IFN-γ, and TNF-α. Our enhancement cascade leads to an antibody dependent improvement in sensitivity up to 40 000 times, resulting in a limit of detection as low as 50 fg/mL and a dynamic detection range of more than 7 logs. Additionally, measurements at these low concentrations are highly reliable with intra- and interassay CVs between 2% and 20%. We subsequently showed this assay is suitable for multiplex measurements with good specificity and limited cross-reactivity. Moreover, we demonstrated robust detection of IL-6 and IL-1β in spiked undiluted equine synovial fluid with small variation compared to buffer controls. In addition, the availability of real time measurements provides extensive quality control opportunities, essential for clinical applications. Therefore, we consider this method is suitable for broad application in SPRi for multiplex biomarker detection in both research and clinical settings.

  5. Does more favourable handling of the cerebrospinal fluid increase the diagnostic sensitivity of Borrelia burgdorferi sensu lato-specific PCR in Lyme neuroborreliosis?

    PubMed

    Forselv, Kristine J N; Lorentzen, Åslaug R; Ljøstad, Unn; Mygland, Åse; Eikeland, Randi; Kjelland, Vivian; Noraas, Sølvi; Quarsten, Hanne

    2018-04-01

    Tests for direct detection of Borrelia burgdorferi sensu lato (Bb) in Lyme neuroborreliosis (LNB) are needed. Detection of Bb DNA using PCR is promising, but clinical utility is hampered by low diagnostic sensitivity. We aimed to examine whether diagnostic sensitivity can be improved by the use of larger cerebrospinal fluid (CSF) volumes and faster handling of samples. Patients who underwent CSF examination for LNB were included. We collected two millilitres of CSF for PCR analysis, extracted DNA from the pellets within 24 h and analysed the eluate by two real-time PCR protocols (16S rRNA and OspA). Patients who fulfilled diagnostic criteria for LNB were classified as LNB cases and the rest as controls. Bb DNA in CSF was detected by PCR in seven of 28 adults with LNB. Two were Bb antibody negative. No Bb DNA was detected in CSF from 137 controls. Diagnostic sensitivity was 25% and specificity 100%. There was a non-significant trend towards larger CSF sample volume, faster handling of the sample, shorter duration of symptoms, and higher CSF cell count in the PCR-positive cases. We did not find that optimized handling of CSF increased diagnostic sensitivity of PCR in adults with LNB. However, our case series is small and we hypothesize that the importance of these factors will be clarified in further studies with larger case series and altered study design. PCR for diagnosis of LNB may be useful in cases without Bb antibodies due to short duration of symptoms.

  6. Small-volume amnioinfusion: a potential stimulus of intrapartum fetal heart rate accelerations.

    PubMed

    Wax, Joseph R; Flaherty, Nina; Pinette, Michael G; Blackstone, Jacquelyn; Cartin, Angelina

    2004-02-01

    We describe a recurrent nonreassuring fetal heart rate pattern in which small-volume amnioinfusions apparently evoked fetal heart rate accelerations suggested fetal well-being, allowing that progressive labor that culminated in the vaginal delivery of a healthy infant.

  7. System for detecting operating errors in a variable valve timing engine using pressure sensors

    DOEpatents

    Wiles, Matthew A.; Marriot, Craig D

    2013-07-02

    A method and control module includes a pressure sensor data comparison module that compares measured pressure volume signal segments to ideal pressure volume segments. A valve actuation hardware remedy module performs a hardware remedy in response to comparing the measured pressure volume signal segments to the ideal pressure volume segments when a valve actuation hardware failure is detected.

  8. Detecting both melanoma depth and volume in vivo with a handheld photoacoustic probe

    NASA Astrophysics Data System (ADS)

    Zhou, Yong; Li, Guo; Zhu, Liren; Li, Chiye; Cornelius, Lynn A.; Wang, Lihong V.

    2016-03-01

    We applied a linear-array-based photoacoustic probe to detect the tumor depth and volume of melanin-containing melanoma in nude mice in vivo. We demonstrated the ability of this linear-array-based system to measure both the depth and volume of melanoma through phantom, ex vivo, and in vivo experiments. The volume detection ability also enables us to accurately calculate the rate of growth of the tumor, which is important in quantifying tumor activity. Our results show that this system can be used for clinical melanoma diagnosis and treatment at the bedside.

  9. Composition Pulse Time-Of-Flight Mass Flow Sensor

    DOEpatents

    Mosier, Bruce P.; Crocker, Robert W.; Harnett, Cindy K. l

    2004-01-13

    A device for measuring fluid flow rates over a wide range of flow rates (<1 nL/min to >10 .mu.L/min) and at pressures at least as great as 10,000 psi. The invention is particularly adapted for use in microfluidic systems. The device operates by producing compositional variations in the fluid, or pulses, that are subsequently detected downstream from the point of creation to derive a flow rate. Each pulse, comprising a small fluid volume, whose composition is different from the mean composition of the fluid, can be created by electrochemical means, such as by electrolysis of a solvent, electrolysis of a dissolved species, or electrodialysis of a dissolved ionic species. Measurements of the conductivity of the fluid can be used to detect the arrival time of the pulses, from which the fluid flow rate can be determined

  10. Spin wave propagation detected over 100 μm in half-metallic Heusler alloy Co2MnSi

    NASA Astrophysics Data System (ADS)

    Stückler, Tobias; Liu, Chuanpu; Yu, Haiming; Heimbach, Florian; Chen, Jilei; Hu, Junfeng; Tu, Sa; Alam, Md. Shah; Zhang, Jianyu; Zhang, Youguang; Farrell, Ian L.; Emeny, Chrissy; Granville, Simon; Liao, Zhi-Min; Yu, Dapeng; Zhao, Weisheng

    2018-03-01

    The field of magnon spintronics offers a charge current free way of information transportation by using spin waves (SWs). Compared to forward volume spin waves for example, Damon-Eshbach (DE) SWs need a relatively weak external magnetic field which is suitable for small spintronic devices. In this work we study DE SWs in Co2MnSi, a half-metallic Heusler alloy with significant potential for magnonics. Thin films have been produced by pulsed laser deposition. Integrated coplanar waveguide (CPW) antennas with different distances between emitter and detection antenna have been prepared on a Co2MnSi film. We used a vector network analyzer to measure spin wave reflection and transmission. We observe spin wave propagation up to 100 μm, a new record for half-metallic Heusler thin films.

  11. Direct electrochemical stripping detection of cystic-fibrosis-related DNA linked through cadmium sulfide quantum dots

    NASA Astrophysics Data System (ADS)

    Marin, Sergio; Merkoçi, Arben

    2009-02-01

    Electrochemical detection of a cadmium sulfide quantum dots (CdS QDs)-DNA complex connected to paramagnetic microbeads (MB) was performed without the need for chemical dissolving. The method is based on dropping 20 µl of CdS QD-DNA-MB suspension on the surface of a screen-printed electrode. It is followed by magnetic collection on the surface of the working electrode and electrochemical detection using square-wave voltammetry (SWV), giving a well-shaped and sensitive analytical signal. A cystic-fibrosis-related DNA sequence was sandwiched between the two DNA probes. One DNA probe is linked via biotin-streptavidin bonding with MB and the other one via thiol groups with the CdS QD used as tags. Nonspecific signals of DNA were minimized using a blocking agent and the results obtained were successfully employed in a model DNA sensor with an interest in future applications in the clinical field. The developed nanoparticle biosensing system may offer numerous opportunities in other fields where fast, low cost and efficient detection of small volume samples is required.

  12. Community biomass handbook volume 4: enterprise development for integrated wood manufacturing

    Treesearch

    Eini Lowell; D.R. Becker; D. Smith; M. Kauffman; D. Bihn

    2017-01-01

    The Community Biomass Handbook Volume 4: Enterprise Development for Integrated Wood Manufacturing is a guide for creating sustainable business enterprises using small diameter logs and biomass. This fourth volume is a companion to three Community Biomass Handbook volumes: Volume 1: Thermal Wood Energy; Volume 2: Alaska, Where Woody Biomass Can Work; and Volume 3: How...

  13. Biophotonics determination of 6-benzylaminopurine (6-BAP) plant growth regulator using OFRR biosensor

    NASA Astrophysics Data System (ADS)

    Yang, Gilmo; Kang, Sukwon; Lee, Kangjin; Kim, Giyoung; Son, Jaeryong; Mo, Changyeun

    2010-04-01

    The identification of pesticide and 6-benzylaminopurine (6-BAP) plant growth regulator was carried out using a label-free opto-fluidic ring resonator (OFRR) biosensor. The OFRR sensing platform is a recent advancement in opto-fluidic technology that integrates photonic sensing technology with microfluidics. It features quick detection time, small sample volume, accurate quantitative and kinetic results. The most predominant advantage of the OFRR integrated with microfluidics is that we can potentially realize the multi-channel and portable biosensor that detects numerous analytes simultaneously. Antisera for immunoassay were raised in rabbits against the 6-BAP-BSA conjugate. Using the immunization protocol and unknown cytokinin reacting with same antibody, comparable sensitivity and specificity were obtained. 6-BAP antibody was routinely used for cytokinin analysis. A sensitive and simple OFRR method with a good linear relationship was developed for the determination of 6-BAP. The detection limit was also examined. The biosensor demonstrated excellent reproducibility when periodically exposed to 6-BAP.

  14. Towards Optical Partial Discharge Detection with Micro Silicon Photomultipliers

    PubMed Central

    Ren, Ming; Song, Bo; Dong, Ming

    2017-01-01

    Optical detection is reliable in intrinsically characterizing partial discharges (PDs). Because of the great volume and high-level power supply of the optical devices that can satisfy the requirements in photosensitivity, optical PD detection can merely be used in laboratory studies. To promote the practical application of the optical approach in an actual power apparatus, a silicon photomultiplier (SiPM)-based PD sensor is introduced in this paper, and its basic properties, which include the sensitivity, pulse resolution, correlation with PD severity, and electromagnetic (EM) interference immunity, are experimentally evaluated. The stochastic phase-resolved PD pattern (PRPD) for three typical insulation defects are obtained by SiPM PD detector and are compared with those obtained using a high-frequency current transformer (HFCT) and a vacuum photomultiplier tube (PMT). Because of its good performances in the above aspects and its additional advantages, such as the small size, low power supply, and low cost, SiPM offers great potential in practical optical PD monitoring. PMID:29125544

  15. Towards Optical Partial Discharge Detection with Micro Silicon Photomultipliers.

    PubMed

    Ren, Ming; Zhou, Jierui; Song, Bo; Zhang, Chongxing; Dong, Ming; Albarracín, Ricardo

    2017-11-10

    Optical detection is reliable in intrinsically characterizing partial discharges (PDs). Because of the great volume and high-level power supply of the optical devices that can satisfy the requirements in photosensitivity, optical PD detection can merely be used in laboratory studies. To promote the practical application of the optical approach in an actual power apparatus, a silicon photomultiplier (SiPM)-based PD sensor is introduced in this paper, and its basic properties, which include the sensitivity, pulse resolution, correlation with PD severity, and electromagnetic (EM) interference immunity, are experimentally evaluated. The stochastic phase-resolved PD pattern (PRPD) for three typical insulation defects are obtained by SiPM PD detector and are compared with those obtained using a high-frequency current transformer (HFCT) and a vacuum photomultiplier tube (PMT). Because of its good performances in the above aspects and its additional advantages, such as the small size, low power supply, and low cost, SiPM offers great potential in practical optical PD monitoring.

  16. Nucifer: A small electron-antineutrino detector for fundamental and safeguard studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Letourneau, A.; Bui, V. M.; Cribier, M.

    The Nucifer detector will be deployed in the next few months at the Osiris research reactor in France. Nucifer is a 1-ton Gd-doped liquid scintillator detector devoted to reactor antineutrino studies. It will be installed 7 m away from the compact core of the Osiris reactor. The design of such small volume detector has been focused on high detection efficiency and good background rejection. Over the last decades, our understanding of the neutrino properties has been improved and allows today the possibility to apply the detection of antineutrinos to automatic and to non intrusively survey nuclear power plant. This hasmore » triggered the interest of the International Atomic Energy Agency (IAEA), which is interested by developing new safeguard techniques for next generation reactors. The sensitivity of such technique has to be proved and demonstrated. On the other hand there is still some issues in our understanding of the neutrino properties as the observed deficit in the antineutrino rate at short distances (< 100 m) that can not be explained by oscillations in the 3-flavors neutrino model. If a global systematic error is rejected, such anomaly opens the door to new physic that can be assessed with small detectors placed close to the core. Here we review the Nucifer detector in this context and the tests we are performing. (authors)« less

  17. Perivascular spaces on 7 Tesla brain MRI are related to markers of small vessel disease but not to age or cardiovascular risk factors

    PubMed Central

    Zwanenburg, Jaco JM; Reinink, Rik; Wisse, Laura EM; Luijten, Peter R; Kappelle, L Jaap; Geerlings, Mirjam I; Biessels, Geert Jan

    2016-01-01

    Cerebral perivascular spaces (PVS) are small physiological structures around blood vessels in the brain. MRI visible PVS are associated with ageing and cerebral small vessel disease (SVD). 7 Tesla (7T) MRI improves PVS detection. We investigated the association of age, vascular risk factors, and imaging markers of SVD with PVS counts on 7 T MRI, in 50 persons aged ≥ 40. The average PVS count ± SD in the right hemisphere was 17 ± 6 in the basal ganglia and 71 ± 28 in the semioval centre. We observed no relation between age or vascular risk factors and PVS counts. The presence of microbleeds was related to more PVS in the basal ganglia (standardized beta 0.32; p = 0.04) and semioval centre (standardized beta 0.39; p = 0.01), and white matter hyperintensity volume to more PVS in the basal ganglia (standardized beta 0.41; p = 0.02). We conclude that PVS counts on 7T MRI are high and are related SVD markers, but not to age and vascular risk factors. This latter finding may indicate that due to the high sensitivity of 7T MRI, the correlation of PVS counts with age or vascular risk factors may be attenuated by the detection of “normal”, non-pathological PVS. PMID:27154503

  18. Detecting metastasis of gastric carcinoma using high-resolution micro-CT system: in vivo small animal study

    NASA Astrophysics Data System (ADS)

    Liu, Junting; Tian, Jie; Liang, Jimin; Li, Xiangsi; Yang, Xiang; Chen, Xiaofeng; Chen, Yi; Zhou, Yuanfang; Wang, Xiaorui

    2011-03-01

    Immunocytochemical and immunofluorescence staining are used for identifying the characteristics of metastasis in traditional ways. Micro-computed tomography (micro-CT) is a useful tool for monitoring and longitudinal imaging of tumor in small animal in vivo. In present study, we evaluated the feasibility of the detection for metastasis of gastric carcinoma by high-resolution micro-CT system with omnipaque accumulative enhancement method in the organs. Firstly, a high-resolution micro-CT ZKKS-MCT-sharp micro-CT was developed by our research group and Guangzhou Zhongke Kaisheng Medical Technology Co., Ltd. Secondly, several gastric carcinoma models were established through inoculating 2x106 BGC-823 gastric carcinoma cells subcutaneously. Thirdly, micro-CT scanning was performed after accumulative enhancement method of intraperitoneal injection of omnipaque contrast agent containing 360 mg iodine with a concentration of 350 mg I/ml. Finally, we obtained high-resolution anatomical information of the metastasis in vivo in a BALB/c NuNu nude mouse, the 3D tumor architecture is revealed in exquisite detail at about 35 μm spatial resolution. In addition, the accurate shape and volume of the micrometastasis as small as 0.78 mm3 can be calculated with our software. Overall, our data suggest that this imaging approach and system could be used to enhance the understanding of tumor proliferation, metastasis and could be the basis for evaluating anti-tumor therapies.

  19. A new multimodality system for quantitative in vivo studies in small animals: combination of nuclear magnetic resonance and the radiosensitive /spl beta/-MicroProbe

    NASA Astrophysics Data System (ADS)

    Desbree, A.; Pain, F.; Gurden, H.; Pinot, L.; Grenier, D.; Zimmer, L.; Mastrippolito, R.; Laniece, P.

    2005-10-01

    Elucidating complex physiological mechanisms in small animal in vivo requires the development of new investigatory techniques including imaging with multiple modalities. Combining exploratory techniques has the tremendous advantage to record simultaneously complementary parameters on the same animal. In this field, an exciting challenge remains in the combination of nuclear magnetic resonance (NMR) and positron emission tomography (PET) since small animals studies are limited by strict technical constraints in vivo. Coupling NMR with a radiosensitive /spl beta/-MicroProbe offers therefore an interesting technical alternative. To assess the feasibility of this new dual-modality system, we designed theoretical and experimental approaches to test the ability of the /spl beta/-Microprobe to quantify radioactivity concentration in an intense magnetic field. In an initial step, simulations were carried out using Geant4. First, we evaluated the influence of a magnetic field on the probe detection volume. Then, the detection sensitivity and energy response of the probe were quantified. In a second step, experiments were run within a 7-T magnet to confirm our simulations results. We showed that using the probe in magnetic fields leads to a slight attenuation in sensitivity and an increase of the scintillation light yield. These data demonstrate the feasibility of combining NMR to the /spl beta/-MicroProbe.

  20. Construction of a Liposome Dialyzer for preparation of high-value, small-volume liposome formulations

    PubMed Central

    Adamala, Katarzyna; Engelhart, Aaron E.; Kamat, Neha P.; Jin, Lin; Szostak, Jack W.

    2016-01-01

    The liposome dialyzer is a small-volume equilibrium dialysis device, built from commercially available materials, that is designed for rapid exchange of small volumes of an extraliposomal reagent pool against a liposome preparation. The dialyzer is prepared by modification of commercially available dialysis cartridges and consists of a reactor with two 300 µL chambers and a 1.56 cm2 dialysis surface area. The dialyzer is prepared in three stages: 1) disassembly of dialysis cartridges to obtain required parts; 2) assembly of the dialyzer; and 3) sealing the dialyzer with epoxy. Preparation of the dialyser takes about 1.5 h, not including overnight epoxy curing. Each round of dialysis takes 1–24 h, depending on the analyte and membrane employed. We previously used the dialyzer for small-volume nonenzymatic RNA synthesis reactions inside fatty acid vesicles. In this protocol, we demonstrate other applications, including removal of unencapsulated calcein from vesicles, remote loading, and vesicle microscopy. PMID:26020615

  1. Construction of a liposome dialyzer for the preparation of high-value, small-volume liposome formulations.

    PubMed

    Adamala, Katarzyna; Engelhart, Aaron E; Kamat, Neha P; Jin, Lin; Szostak, Jack W

    2015-06-01

    The liposome dialyzer is a small-volume equilibrium dialysis device, built from commercially available materials, that is designed for the rapid exchange of small volumes of an extraliposomal reagent pool against a liposome preparation. The dialyzer is prepared by modification of commercially available dialysis cartridges (Slide-A-Lyzer cassettes), and it consists of a reactor with two 300-μl chambers and a 1.56-cm(2) dialysis surface area. The dialyzer is prepared in three stages: (i) disassembling the dialysis cartridges to obtain the required parts, (ii) assembling the dialyzer and (iii) sealing the dialyzer with epoxy. Preparation of the dialyzer takes ∼1.5 h, not including overnight epoxy curing. Each round of dialysis takes 1-24 h, depending on the analyte and membrane used. We previously used the dialyzer for small-volume non-enzymatic RNA synthesis reactions inside fatty acid vesicles. In this protocol, we demonstrate other applications, including removal of unencapsulated calcein from vesicles, remote loading and vesicle microscopy.

  2. A radiographic method to estimate lung volume and its use in small mammals.

    PubMed

    Canals, Mauricio; Olivares, Ricardo; Rosenmann, Mario

    2005-01-01

    In this paper we develop a method to estimate lung volume using chest x-rays of small mammals. We applied this method to assess the lung volume of several rodents. We showed that a good estimator of the lung volume is: V*L = 0.496 x VRX approximately equal to 1/2 x VRX, where VRX is a measurement obtained from the x-ray that represents the volume of a rectangular box containing the lungs and mediastinum organs. The proposed formula may be interpreted as the volume of an ellipsoid formed by both lungs joined at their bases. When that relationship was used to estimate lung volume, values similar to those expected from allometric relationship were found in four rodents. In two others, M. musculus and R. norvegicus, lung volume was similar to reported data, although values were lower than expected.

  3. Molecular Profiling of Malignant Pleural Effusion in Metastatic Non-Small-Cell Lung Carcinoma. The Effect of Preanalytical Factors.

    PubMed

    Carter, Jamal; Miller, James Adam; Feller-Kopman, David; Ettinger, David; Sidransky, David; Maleki, Zahra

    2017-07-01

    Non-small-cell lung cancer (NSCLC)-associated malignant pleural effusions (MPEs) are sometimes the only available specimens for molecular analysis. This study evaluates diagnostic yield of NSCLC-associated MPE, its adequacy for molecular profiling and the potential influence of MPE volume/cellularity on the analytic sensitivity of our assays. Molecular results of 50 NSCLC-associated MPE cases during a 5-year period were evaluated. Molecular profiling was performed on cell blocks and consisted of fluorescent in situ hybridization (FISH) for ALK gene rearrangements and the following sequencing platforms: Sanger sequencing (for EGFR) and high-throughput pyrosequencing (for KRAS and BRAF) during the first 4 years of the study period, and targeted next-generation sequencing performed thereafter. A total of 50 NSCLC-associated MPE cases were identified where molecular testing was requested. Of these, 17 cases were excluded: 14 cases (28%) due to inadequate tumor cellularity and 3 cases due to unavailability of the slides to review. A total of 27 out of 50 MPE cases (54%) underwent at least EGFR and KRAS sequencing and FISH for ALK rearrangement. Of the 27 cases with molecular testing results available, a genetic abnormality was detected in 16 cases (59%). The most common genetic aberrations identified involved EGFR ( 9 ) and KRAS ( 7 ). Six cases had ALK FISH only, of which one showed rearrangement. MPE volume was not associated with overall cellularity or tumor cellularity (P = 0.360). Molecular profiling of MPE is a viable alternative to testing solid tissue in NSCLC. This study shows successful detection of genetic aberrations in 59% of samples with minimal risk of false negative.

  4. Gene doping detection: evaluation of approach for direct detection of gene transfer using erythropoietin as a model system.

    PubMed

    Baoutina, A; Coldham, T; Bains, G S; Emslie, K R

    2010-08-01

    As clinical gene therapy has progressed toward realizing its potential, concern over misuse of the technology to enhance performance in athletes is growing. Although 'gene doping' is banned by the World Anti-Doping Agency, its detection remains a major challenge. In this study, we developed a methodology for direct detection of the transferred genetic material and evaluated its feasibility for gene doping detection in blood samples from athletes. Using erythropoietin (EPO) as a model gene and a simple in vitro system, we developed real-time PCR assays that target sequences within the transgene complementary DNA corresponding to exon/exon junctions. As these junctions are absent in the endogenous gene due to their interruption by introns, the approach allows detection of trace amounts of a transgene in a large background of the endogenous gene. Two developed assays and one commercial gene expression assay for EPO were validated. On the basis of ability of these assays to selectively amplify transgenic DNA and analysis of literature on testing of gene transfer in preclinical and clinical gene therapy, it is concluded that the developed approach would potentially be suitable to detect gene doping through gene transfer by analysis of small volumes of blood using regular out-of-competition testing.

  5. Classification of SD-OCT volumes for DME detection: an anomaly detection approach

    NASA Astrophysics Data System (ADS)

    Sankar, S.; Sidibé, D.; Cheung, Y.; Wong, T. Y.; Lamoureux, E.; Milea, D.; Meriaudeau, F.

    2016-03-01

    Diabetic Macular Edema (DME) is the leading cause of blindness amongst diabetic patients worldwide. It is characterized by accumulation of water molecules in the macula leading to swelling. Early detection of the disease helps prevent further loss of vision. Naturally, automated detection of DME from Optical Coherence Tomography (OCT) volumes plays a key role. To this end, a pipeline for detecting DME diseases in OCT volumes is proposed in this paper. The method is based on anomaly detection using Gaussian Mixture Model (GMM). It starts with pre-processing the B-scans by resizing, flattening, filtering and extracting features from them. Both intensity and Local Binary Pattern (LBP) features are considered. The dimensionality of the extracted features is reduced using PCA. As the last stage, a GMM is fitted with features from normal volumes. During testing, features extracted from the test volume are evaluated with the fitted model for anomaly and classification is made based on the number of B-scans detected as outliers. The proposed method is tested on two OCT datasets achieving a sensitivity and a specificity of 80% and 93% on the first dataset, and 100% and 80% on the second one. Moreover, experiments show that the proposed method achieves better classification performances than other recently published works.

  6. Analytical evaluation of BEA zeolite for the pre-concentration of polycyclic aromatic hydrocarbons and their subsequent chromatographic analysis in water samples.

    PubMed

    Wilson, Walter B; Costa, Andréia A; Wang, Huiyong; Dias, José A; Dias, Sílvia C L; Campiglia, Andres D

    2012-07-06

    The analytical performance of BEA - a commercial zeolite - is evaluated for the pre-concentration of fifteen Environmental Protection Agency - polycyclic aromatic hydrocarbons and their subsequent HPLC analysis in tap and lake water samples. The pre-concentration factors obtained with BEA have led to a method with excellent analytical figures of merit. One milliliter aliquots were sufficient to obtain excellent precision of measurements at the parts-per-trillion concentration level with relative standard deviations varying from 4.1% (dibenzo[a,h]anthracene) to 13.4% (pyrene). The limits of detection were excellent as well and varied between 1.1 (anthracene) and 49.9 ng L(-1) (indeno[1,2,3-cd]pyrene). The recovery values of all the studied compounds meet the criterion for regulated polycyclic aromatic hydrocarbons, which mandates relative standard deviations equal or lower than 25%. The small volume of organic solvents (100 μL per sample) and amount of BEA (2 mg per sample) makes sample pre-concentration environmentally friendly and cost effective. The extraction procedure is well suited for numerous samples as the small working volume (1 mL) facilitates the implementation of simultaneous sample extraction. These are attractive features when routine monitoring of numerous samples is contemplated. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Measuring Blood Glucose Concentrations in Photometric Glucometers Requiring Very Small Sample Volumes.

    PubMed

    Demitri, Nevine; Zoubir, Abdelhak M

    2017-01-01

    Glucometers present an important self-monitoring tool for diabetes patients and, therefore, must exhibit high accuracy as well as good usability features. Based on an invasive photometric measurement principle that drastically reduces the volume of the blood sample needed from the patient, we present a framework that is capable of dealing with small blood samples, while maintaining the required accuracy. The framework consists of two major parts: 1) image segmentation; and 2) convergence detection. Step 1 is based on iterative mode-seeking methods to estimate the intensity value of the region of interest. We present several variations of these methods and give theoretical proofs of their convergence. Our approach is able to deal with changes in the number and position of clusters without any prior knowledge. Furthermore, we propose a method based on sparse approximation to decrease the computational load, while maintaining accuracy. Step 2 is achieved by employing temporal tracking and prediction, herewith decreasing the measurement time, and, thus, improving usability. Our framework is tested on several real datasets with different characteristics. We show that we are able to estimate the underlying glucose concentration from much smaller blood samples than is currently state of the art with sufficient accuracy according to the most recent ISO standards and reduce measurement time significantly compared to state-of-the-art methods.

  8. Development and validation of a sensitive HPLC method for the quantification of HI-6 in guinea pig plasma and evaluated in domestic swine.

    PubMed

    Bohnert, Sara; Vair, Cory; Mikler, John

    2010-05-15

    A rapid and small volume assay to quantify HI-6 in plasma was developed to further the development and licensing of an intravenous formulation of HI-6. The objective of this method was to develop a sensitive and rapid assay that clearly resolved HI-6 and an internal standard in saline and plasma matrices. A fully validated method using ion-pair HPLC and 2-PAM as the internal standard fulfilled these requirements. Small plasma samples of 35 microL were extracted using acidification, filtration and neutralization. Linearity was shown for over 4 microg/mL to 1mg/mL with accuracy and precision within 6% relative error at the lower limit of detection. This method was utilized in the pharmacokinetic analysis HI-6 dichloride (2Cl) and HI-6 dimethane sulfonate (DMS) in anaesthetized guinea pigs and domestic swine following an intravenous bolus administration. From the resultant pharmacokinetic parameters a target plasma concentration of 100 microM was established and maintained in guinea pigs receiving an intravenous infusion. This validated method allows for the analysis of low volume samples, increased sample numbers and is applicable to the determination of pharmacokinetic profiles and parameters. Copyright (c) 2010. Published by Elsevier B.V.

  9. A generalized quantitative interpretation of dark-field contrast for highly concentrated microsphere suspensions

    PubMed Central

    Gkoumas, Spyridon; Villanueva-Perez, Pablo; Wang, Zhentian; Romano, Lucia; Abis, Matteo; Stampanoni, Marco

    2016-01-01

    In X-ray grating interferometry, dark-field contrast arises due to partial extinction of the detected interference fringes. This is also called visibility reduction and is attributed to small-angle scattering from unresolved structures in the imaged object. In recent years, analytical quantitative frameworks of dark-field contrast have been developed for highly diluted monodisperse microsphere suspensions with maximum 6% volume fraction. These frameworks assume that scattering particles are separated by large enough distances, which make any interparticle scattering interference negligible. In this paper, we start from the small-angle scattering intensity equation and, by linking Fourier and real-space, we introduce the structure factor and thus extend the analytical and experimental quantitative interpretation of dark-field contrast, for a range of suspensions with volume fractions reaching 40%. The structure factor accounts for interparticle scattering interference. Without introducing any additional fitting parameters, we successfully predict the experimental values measured at the TOMCAT beamline, Swiss Light Source. Finally, we apply this theoretical framework to an experiment probing a range of system correlation lengths by acquiring dark-field images at different energies. This proposed method has the potential to be applied in single-shot-mode using a polychromatic X-ray tube setup and a single-photon-counting energy-resolving detector. PMID:27734931

  10. Volume measurements on three-dimensional photogrammetry after extended strip versus total cranial remodeling for sagittal synostosis: A comparative cohort study.

    PubMed

    van Veelen, Marie-Lise C; Jippes, Marielle; Carolina, Julius-Carl A; de Rooi, Johan; Dirven, Clemens M F; van Adrichem, Leon N A; Mathijssen, Irene M

    2016-10-01

    Surgery for sagittal synostosis aims at correction of skull shape and restoration of growth potential. Small cranial volume is associated with raised intracranial pressure (ICP). Although many techniques have been described, information on postoperative volume related to early and late remodeling is lacking. Between 2004 and 2008, a total of 95 patients were collected who underwent either early extended strip craniectomy or late total cranial remodeling according to age of presentation. Volume was measured on three-dimensional (3D) photogrammetry. Volume measurements were related to cranial index (CI), head circumference (HCsd), and signs of raised ICP. In a small subset of patients, volume measurements on 3D photogrammetry were assessed for inter- and intrarater reliability and compared to 3D computed tomography (CT). Volume was increased in all patients before and after surgery compared to normative values. Postoperatively, late total cranial remodeling resulted in a slightly larger volume than early extended strip craniectomy. Volume measurements showed a good correlation with HCsd (0.67) and a poor relationship with CI (0.13). Headache occurred more frequently in patients with a lower cranial volume. Although papilledema and reoperation showed the same trend, the numbers were too small for statistical analysis. Reproducibility of volume measurements on 3D photogrammetry was high, as was the correlation with measurements on CT. Late total cranial remodeling results in a larger postoperative volume, as measured on 3D photogrammetry, than extended strip craniectomy. Clinical signs of raised ICP occur more frequently in patients with a smaller volume. To measure volume, 3D photogrammetry is a good alternative to CT. Copyright © 2016. Published by Elsevier Ltd.

  11. Dependence of the clustering properties of galaxies on stellar velocity dispersion in the Main galaxy sample of SDSS DR10

    NASA Astrophysics Data System (ADS)

    Deng, Xin-Fa; Song, Jun; Chen, Yi-Qing; Jiang, Peng; Ding, Ying-Ping

    2014-08-01

    Using two volume-limited Main galaxy samples of the Sloan Digital Sky Survey Data Release 10 (SDSS DR10), we investigate the dependence of the clustering properties of galaxies on stellar velocity dispersion by cluster analysis. It is found that in the luminous volume-limited Main galaxy sample, except at r=1.2, richer and larger systems can be more easily formed in the large stellar velocity dispersion subsample, while in the faint volume-limited Main galaxy sample, at r≥0.9, an opposite trend is observed. According to statistical analyses of the multiplicity functions, we conclude in two volume-limited Main galaxy samples: small stellar velocity dispersion galaxies preferentially form isolated galaxies, close pairs and small group, while large stellar velocity dispersion galaxies preferentially inhabit the dense groups and clusters. However, we note the difference between two volume-limited Main galaxy samples: in the faint volume-limited Main galaxy sample, at r≥0.9, the small stellar velocity dispersion subsample has a higher proportion of galaxies in superclusters ( n≥200) than the large stellar velocity dispersion subsample.

  12. Lightning Mapping Observations of Volume-Filling Small Discharges in Thunderstorms

    NASA Astrophysics Data System (ADS)

    Rison, W.; Krehbiel, P. R.; Thomas, R. J.; Rodeheffer, D.

    2013-12-01

    Lightning is usually considered to be a large-scale electrical discharge in the atmosphere. For example, the American Meteorological Society's Glossary of Meteorology defines lightning as "a transient, high-current electric discharge with pathlengths measured in kilometers" (http://glossary.ametsoc.org/wiki/Lightning). There have been several reported examples of short-duration discharges in thunderstorms, which have a duration of a few microseconds to less than a millisecond, and have a small spatial extent These short-duration discharges were located at high altitudes (> 14 km), altitudes consistent with being located between the upper positive charge and the negative screening layer. At these altitudes, the electric field needed to initiate an electrical discharge is much lower than it is at the altitudes of initiation for IC (~8 km) or CG (~5 km) flashes. We have recently reported on short-duration "precursor" discharges with durations of a few microseconds to a few milliseconds, which occur in the high-fields between the mid-level negative and upper positive charge regions. These "precursor" discharges are discrete in both time and space, being separated in time by hundreds of milliseconds to several seconds, and localized in space, usually very close to the initiation location of a subsequent IC discharge. We have recently observed nearly continuous, volume filling short-duration discharges in several thunderstorms. These discharges have durations of much less than a millisecond, spatial extents of less than a few hundred meters, and occur randomly in the volume between the mid-level negative and upper positive charge regions. During an active period, these discharges occur every few milliseconds. The rates of these discharges decreases dramatically to a few per second following an IC discharge, then increases to several hundred per second until the next discharge. In a storm just off the Florida coast, one cell was producing a large number of these small discharges, while a contemporaneous cell a few kilometers west produced no detectable small discharges. Short-duration discharges occur at altitudes between 10 km and 14 km in the intervals between lightning discharges. The rates of short-duration discharges decreases dramatically after a lightning discharge.

  13. The Consequences of Metric Production for Small Manufacturers. Volume II. Case Studies of Large Business-Small Business Interaction,

    DTIC Science & Technology

    1982-02-08

    II 00 CASE STUDIES OF LARGE BUSINESS - SMALL BUSINESS INTERACTION ’C- DTIC. Henry H1. Hitchcock dlELECTE7 Joseph F. Coates Marcy M. Canavan AUGG261982...J wis&omWWS1ARET N W WASIINGTOW. OC NO$I THE CONSEQUENCES OF METRIC PRODUCTION FOR SMALL MANUFACTURERS Volume 11 CASE STUDIES OF LARGE BUSINESS ... SMALL BUSINESS INTERACTION Accesqi~r, For NTIS GRA&t DTIC TAB Unannoun~ced J’htiI’ctof _ Henry H. Hitchcock vi 1ribr i t o aes Joseph F. Coates Avail arid

  14. Systems for detecting charged particles in object inspection

    DOEpatents

    Morris, Christopher L.; Makela, Mark F.

    2013-08-20

    Techniques, apparatus and systems for detecting particles such as muons. In one implementation, a monitoring system has a cosmic ray-produced charged particle tracker with a plurality of drift cells. The drift cells, which can be for example aluminum drift tubes, can be arranged at least above and below a volume to be scanned to thereby track incoming and outgoing charged particles, such as cosmic ray-produced muons, while also detecting gamma rays. The system can selectively detect devices or materials, such as iron, lead, gold and/or tungsten, occupying the volume from multiple scattering of the charged particles passing through the volume and can also detect any radioactive sources occupying the volume from gamma rays emitted therefrom. If necessary, the drift tubes can be sealed to eliminate the need for a gas handling system. The system can be employed to inspect occupied vehicles at border crossings for nuclear threat objects.

  15. The Retriever, Volume 2, Nos. 1 & 2, 1967. ERIC Clearinghouse on Rural Education and Small Schools (CRESS) Newsletter.

    ERIC Educational Resources Information Center

    ERIC Clearinghouse on Rural Education and Small Schools, Las Cruces, NM.

    Volume 2, Numbers 1 and 2 of the ERIC/CRESS (Educational Research Information Center/Clearinghouse on Rural education and Small Schools) newsletter focus on the status of CRESS and innovations in the small rural school. Issue Number 1 discusses the status of the Clearinghouse at the end of 3 months into the second year of operation. A 14-item…

  16. COLLECTION EFFICIENCY OF THE HIGH VOLUME SMALL SURFACE SAMPLER ON WORN CARPETS

    EPA Science Inventory

    Collection Efficiency of the High Volume Small Surface Sampler on Worn Carpets

    Erik R. Svendsen*?, Peter S. Thorne*, Stephen J. Reynolds*?, Patrick T. O'Shaughnessy*, Alba Quinones*, Dale Zimmerman*, and Nervana Metwali*

    *University of Iowa College of Public Health<...

  17. Black Cherry Volume Tables for Furniture-Type, Flat, 4/4-Inch Dimension from Small Low-Quality Trees.

    Treesearch

    Eugene F. Landt

    1974-01-01

    Volume tables are given for yield of clear-one-side, flat dimension from small, low-quality trees and boldts removed in a stand improvement cut of 54- to 76-year-old black cherry trees from northern Pennsylvania.

  18. Soft Maple Volume Tables for Furniture-Type, Flat, 4/4-Inch Dimension from Small Low-Quality Trees

    Treesearch

    Eugene F. Landt

    1974-01-01

    Volume tables are given for yield of clear-one-side, flat dimension from small low-quality trees and bolts removed in a stand improvemtn cut of 18- to 44-year-old soft maple trees in southern Illinois.

  19. Novel drift structures for silicon and compound semiconductor X-ray and gamma-ray detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patt, B.E.; Iwanczyk, J.S.

    Recently developed silicon- and compound-semiconductor-based drift detector structures have produced excellent performance for charged particles, X-rays, and gamma rays and for low-signal visible light detection. The silicon drift detector (SDD) structures that the authors discuss relate to direct X-ray detectors and scintillation photon detectors coupled with scintillators for gamma rays. Recent designs include several novel features that ensure very low dark current and hence low noise. In addition, application of thin window technology ensures a very high quantum efficiency entrance window on the drift photodetector. The main features of the silicon drift structures for X rays and light detection aremore » very small anode capacitance independent of the overall detector size, low noise, and high throughput. To take advantage of the small detector capacitance, the first stage of the electronics needs to be integrated into the detector anode. In the gamma-ray application, factors other than electronic noise dominate, and there is no need to integrate the electronics into the anode. Thus, a different drift structure is needed in conjunction with a high-Z material. The main features in this case are large active detector volume and electron-only induced signal.« less

  20. High-frequency Ultrasound Imaging of Mouse Cervical Lymph Nodes.

    PubMed

    Walk, Elyse L; McLaughlin, Sarah L; Weed, Scott A

    2015-07-25

    High-frequency ultrasound (HFUS) is widely employed as a non-invasive method for imaging internal anatomic structures in experimental small animal systems. HFUS has the ability to detect structures as small as 30 µm, a property that has been utilized for visualizing superficial lymph nodes in rodents in brightness (B)-mode. Combining power Doppler with B-mode imaging allows for measuring circulatory blood flow within lymph nodes and other organs. While HFUS has been utilized for lymph node imaging in a number of mouse  model systems, a detailed protocol describing HFUS imaging and characterization of the cervical lymph nodes in mice has not been reported. Here, we show that HFUS can be adapted to detect and characterize cervical lymph nodes in mice. Combined B-mode and power Doppler imaging can be used to detect increases in blood flow in immunologically-enlarged cervical nodes. We also describe the use of B-mode imaging to conduct fine needle biopsies of cervical lymph nodes to retrieve lymph tissue for histological  analysis. Finally, software-aided steps are described to calculate changes in lymph node volume and to visualize changes in lymph node morphology following image reconstruction. The ability to visually monitor changes in cervical lymph node biology over time provides a simple and powerful technique for the non-invasive monitoring of cervical lymph node alterations in preclinical mouse models of oral cavity disease.

  1. Automatic detection and segmentation of brain metastases on multimodal MR images with a deep convolutional neural network.

    PubMed

    Charron, Odelin; Lallement, Alex; Jarnet, Delphine; Noblet, Vincent; Clavier, Jean-Baptiste; Meyer, Philippe

    2018-04-01

    Stereotactic treatments are today the reference techniques for the irradiation of brain metastases in radiotherapy. The dose per fraction is very high, and delivered in small volumes (diameter <1 cm). As part of these treatments, effective detection and precise segmentation of lesions are imperative. Many methods based on deep-learning approaches have been developed for the automatic segmentation of gliomas, but very little for that of brain metastases. We adapted an existing 3D convolutional neural network (DeepMedic) to detect and segment brain metastases on MRI. At first, we sought to adapt the network parameters to brain metastases. We then explored the single or combined use of different MRI modalities, by evaluating network performance in terms of detection and segmentation. We also studied the interest of increasing the database with virtual patients or of using an additional database in which the active parts of the metastases are separated from the necrotic parts. Our results indicated that a deep network approach is promising for the detection and the segmentation of brain metastases on multimodal MRI. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Instrumentation of Molecular Imaging on Site-Specific Targeting Fluorescent Peptide for Early Detection of Breast Cancer

    NASA Astrophysics Data System (ADS)

    Yu, Ping; Ma, Lixin

    2012-02-01

    In this work we developed two biomedical imaging techniques for early detection of breast cancer. Both image modalities provide molecular imaging capability to probe site-specific targeting dyes. The first technique, heterodyne CCD fluorescence mediated tomography, is a non-invasive biomedical imaging that uses fluorescent photons from the targeted dye on the tumor cells inside human breast tissue. The technique detects a large volume of tissue (20 cm) with a moderate resolution (1 mm) and provides the high sensitivity. The second technique, dual-band spectral-domain optical coherence tomography, is a high-resolution tissue imaging modality. It uses a low coherence interferometer to detect coherent photons hidden in the incoherent background. Due to the coherence detection, a high resolution (20 microns) is possible. We have finished prototype imaging systems for the development of both image modalities and performed imaging experiments on tumor tissues. The spectroscopic/tomographic images show contrasts of dense tumor tissues and tumor necrotic regions. In order to correlate the findings from our results, a diffusion-weighted magnetic resonance imaging (MRI) of the tumors was performed using a small animal 7-Telsa MRI and demonstrated excellent agreement.

  3. Hot-Volumes as Uniform and Reproducible SERS-Detection Enhancers in Weakly-Coupled Metallic Nanohelices

    NASA Astrophysics Data System (ADS)

    Caridad, José M.; Winters, Sinéad; McCloskey, David; Duesberg, Georg S.; Donegan, John F.; Krstić, Vojislav

    2017-03-01

    Reproducible and enhanced optical detection of molecules in low concentrations demands simultaneously intense and homogeneous electric fields acting as robust signal amplifiers. To generate such sophisticated optical near-fields, different plasmonic nanostructures were investigated in recent years. These, however, exhibit either high enhancement factor (EF) or spatial homogeneity but not both. Small interparticle gaps or sharp nanostructures show enormous EFs but no near-field homogeneity. Meanwhile, approaches using rounded and separated monomers create uniform near-fields with moderate EFs. Here, guided by numerical simulations, we show how arrays of weakly-coupled Ag nanohelices achieve both homogeneous and strong near-field enhancements, reaching even the limit forreproducible detection of individual molecules. The unique near-field distribution of a single nanohelix consists of broad hot-spots, merging with those from neighbouring nanohelices in specific array configurations and generating a wide and uniform detection zone (“hot-volume”). We experimentally assessed these nanostructures via surface-enhanced Raman spectroscopy, obtaining a corresponding EF of ~107 and a relative standard deviation <10%. These values demonstrate arrays of nanohelices as state-of-the-art substrates for reproducible optical detection as well as compelling nanostructures for related fields such as near-field imaging.

  4. Electrochemical and photoelectrochemical nano-immunesensing using origami paper based method.

    PubMed

    Hasanzadeh, Mohammad; Shadjou, Nasrin

    2016-04-01

    Patterned paper has characteristics that lead to miniaturized assays that run by capillary action with small volumes of fluids. These methods suggest a path for the development of simple, inexpensive, and portable diagnostic assays that can be useful in remote settings, where simple immunoassays are becoming increasingly important for detecting disease and monitoring health. Incorporation of nanomaterials plays a major role in sensing probe immobilization and detection sensitivity of paper-based devices. Nanomaterial properties, such as increased surface area, have aided with signal amplification and lower detection limits. This review focuses on application of nanomaterials as signal amplification elements on origami paper-based electro-analytical devices for immune biomarkers detection with a brief introduction about various fabrication techniques and designs, biological and detection methods. In this review, we comprehensively summarize the selected latest research articles from 2013 to May 2015 on application of nanomaterials in various types of origami paper based electrochemical and photoelectrochemical immunosensors. The review breaks into two parts. The first part devotes to the development and applications of nanomaterials in electrochemical immunesensing. The second part provides an overview of recent origami paper based photoelectrochemical immunosensors. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Detecting an Extended Light Source through a Lens

    ERIC Educational Resources Information Center

    Litaker, E. T.; Machacek, J. R.; Gay, T. J.

    2011-01-01

    We present a Monte Carlo simulation of a cylindrical luminescent volume and a typical lens-detector system. The results of this simulation yield a graphically simple picture of the regions within the cylindrical volume from which this system detects light. Because the cylindrical volume permits large angles of incidence, we use a modification of…

  6. The Dose-Volume Relationship of Small Bowel Irradiation and Acute Grade 3 Diarrhea During Chemoradiotherapy for Rectal Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robertson, John M.; Lockman, David; Yan Di

    Purpose: Previous work has found a highly significant relationship between the irradiated small-bowel volume and development of Grade 3 small-bowel toxicity in patients with rectal cancer. This study tested the previously defined parameters in a much larger group of patients. Methods and Materials: A total of 96 consecutive patients receiving pelvic radiation therapy for rectal cancer had treatment planning computed tomographic scans with small-bowel contrast that allowed the small bowel to be outlined with calculation of a small-bowel dose-volume histogram for the initial intended pelvic treatment to 45 Gy. Patients with at least one parameter above the previously determined dose-volumemore » parameters were considered high risk, whereas those with all parameters below these levels were low risk. The grade of diarrhea and presence of liquid stool was determined prospectively. Results: There was a highly significant association with small-bowel dose-volume and Grade 3 diarrhea (p {<=} 0.008). The high-risk and low-risk parameters were predictive with Grade 3 diarrhea in 16 of 51 high-risk patients and in 4 of 45 low-risk patients (p = 0.01). Patients who had undergone irradiation preoperatively had a lower incidence of Grade 3 diarrhea than those treated postoperatively (18% vs. 28%; p = 0.31); however, the predictive ability of the high-risk/low-risk parameters was better for preoperatively (p = 0.03) than for postoperatively treated patients (p = 0.15). Revised risk parameters were derived that improved the overall predictive ability (p = 0.004). Conclusions: The highly significant dose-volume relationship and validity of the high-risk and low-risk parameters were confirmed in a large group of patients. The risk parameters provided better modeling for the preoperative patients than for the postoperative patients.« less

  7. Quantification of gastrointestinal liquid volumes and distribution following a 240 mL dose of water in the fasted state.

    PubMed

    Mudie, Deanna M; Murray, Kathryn; Hoad, Caroline L; Pritchard, Susan E; Garnett, Martin C; Amidon, Gordon L; Gowland, Penny A; Spiller, Robin C; Amidon, Gregory E; Marciani, Luca

    2014-09-02

    The rate and extent of drug dissolution and absorption from solid oral dosage forms is highly dependent upon the volumes and distribution of gastric and small intestinal water. However, little is known about the time courses and distribution of water volumes in vivo in an undisturbed gut. Previous imaging studies offered a snapshot of water distribution in fasted humans and showed that water in the small intestine is distributed in small pockets. This study aimed to quantify the volume and number of water pockets in the upper gut of fasted healthy humans following ingestion of a glass of water (240 mL, as recommended for bioavailability/bioequivalence (BA/BE) studies), using recently validated noninvasive magnetic resonance imaging (MRI) methods. Twelve healthy volunteers underwent upper and lower abdominal MRI scans before drinking 240 mL (8 fluid ounces) of water. After ingesting the water, they were scanned at intervals for 2 h. The drink volume, inclusion criteria, and fasting conditions matched the international standards for BA/BE testing in healthy volunteers. The images were processed for gastric and intestinal total water volumes and for the number and volume of separate intestinal water pockets larger than 0.5 mL. The fasted stomach contained 35 ± 7 mL (mean ± SEM) of resting water. Upon drinking, the gastric fluid rose to 242 ± 9 mL. The gastric water volume declined rapidly after that with a half emptying time (T50%) of 13 ± 1 min. The mean gastric volume returned back to baseline 45 min after the drink. The fasted small bowel contained a total volume of 43 ± 14 mL of resting water. Twelve minutes after ingestion of water, small bowel water content rose to a maximum value of 94 ± 24 mL contained within 15 ± 2 pockets of 6 ± 2 mL each. At 45 min, when the glass of water had emptied completely from the stomach, total intestinal water volume was 77 ± 15 mL distributed into 16 ± 3 pockets of 5 ± 1 mL each. MRI provided unprecedented insights into the time course, number, volume, and location of water pockets in the stomach and small intestine under conditions that represent standard BA/BE studies using validated techniques. These data add to our current understanding of gastrointestinal physiology and will help improve physiological relevance of in vitro testing methods and in silico transport analyses for prediction of bioperformance of oral solid dosage forms, particularly for low solubility Biopharmaceutics Classification System (BCS) Class 2 and Class 4 compounds.

  8. Dual multispectral and 3D structured light laparoscope

    NASA Astrophysics Data System (ADS)

    Clancy, Neil T.; Lin, Jianyu; Arya, Shobhit; Hanna, George B.; Elson, Daniel S.

    2015-03-01

    Intraoperative feedback on tissue function, such as blood volume and oxygenation would be useful to the surgeon in cases where current clinical practice relies on subjective measures, such as identification of ischaemic bowel or tissue viability during anastomosis formation. Also, tissue surface profiling may be used to detect and identify certain pathologies, as well as diagnosing aspects of tissue health such as gut motility. In this paper a dual modality laparoscopic system is presented that combines multispectral reflectance and 3D surface imaging. White light illumination from a xenon source is detected by a laparoscope-mounted fast filter wheel camera to assemble a multispectral image (MSI) cube. Surface shape is then calculated using a spectrally-encoded structured light (SL) pattern detected by the same camera and triangulated using an active stereo technique. Images of porcine small bowel were acquired during open surgery. Tissue reflectance spectra were acquired and blood volume was calculated at each spatial pixel across the bowel wall and mesentery. SL features were segmented and identified using a `normalised cut' algoritm and the colour vector of each spot. Using the 3D geometry defined by the camera coordinate system the multispectral data could be overlaid onto the surface mesh. Dual MSI and SL imaging has the potential to provide augmented views to the surgeon supplying diagnostic information related to blood supply health and organ function. Future work on this system will include filter optimisation to reduce noise in tissue optical property measurement, and minimise spot identification errors in the SL pattern.

  9. Compensating temperature-induced ultrasonic phase and amplitude changes

    NASA Astrophysics Data System (ADS)

    Gong, Peng; Hay, Thomas R.; Greve, David W.; Junker, Warren R.; Oppenheim, Irving J.

    2016-04-01

    In ultrasonic structural health monitoring (SHM), environmental and operational conditions, especially temperature, can significantly affect the propagation of ultrasonic waves and thus degrade damage detection. Typically, temperature effects are compensated using optimal baseline selection (OBS) or optimal signal stretch (OSS). The OSS method achieves compensation by adjusting phase shifts caused by temperature, but it does not fully compensate phase shifts and it does not compensate for accompanying signal amplitude changes. In this paper, we develop a new temperature compensation strategy to address both phase shifts and amplitude changes. In this strategy, OSS is first used to compensate some of the phase shifts and to quantify the temperature effects by stretching factors. Based on stretching factors, empirical adjusting factors for a damage indicator are then applied to compensate for the temperature induced remaining phase shifts and amplitude changes. The empirical adjusting factors can be trained from baseline data with temperature variations in the absence of incremental damage. We applied this temperature compensation approach to detect volume loss in a thick wall aluminum tube with multiple damage levels and temperature variations. Our specimen is a thick-walled short tube, with dimensions closely comparable to the outlet region of a frac iron elbow where flow-induced erosion produces the volume loss that governs the service life of that component, and our experimental sequence simulates the erosion process by removing material in small damage steps. Our results show that damage detection is greatly improved when this new temperature compensation strategy, termed modified-OSS, is implemented.

  10. Fractal dimension of microbead assemblies used for protein detection.

    PubMed

    Hecht, Ariel; Commiskey, Patrick; Lazaridis, Filippos; Argyrakis, Panos; Kopelman, Raoul

    2014-11-10

    We use fractal analysis to calculate the protein concentration in a rotating magnetic assembly of microbeads of size 1 μm, which has optimized parameters of sedimentation, binding sites and magnetic volume. We utilize the original Forrest-Witten method, but due to the relatively small number of bead particles, which is of the order of 500, we use a large number of origins and also a large number of algorithm iterations. We find a value of the fractal dimension in the range 1.70-1.90, as a function of the thrombin concentration, which plays the role of binding the microbeads together. This is in good agreement with previous results from magnetorotation studies. The calculation of the fractal dimension using multiple points of reference can be used for any assembly with a relatively small number of particles. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Pre-Capture Privacy for Small Vision Sensors.

    PubMed

    Pittaluga, Francesco; Koppal, Sanjeev Jagannatha

    2017-11-01

    The next wave of micro and nano devices will create a world with trillions of small networked cameras. This will lead to increased concerns about privacy and security. Most privacy preserving algorithms for computer vision are applied after image/video data has been captured. We propose to use privacy preserving optics that filter or block sensitive information directly from the incident light-field before sensor measurements are made, adding a new layer of privacy. In addition to balancing the privacy and utility of the captured data, we address trade-offs unique to miniature vision sensors, such as achieving high-quality field-of-view and resolution within the constraints of mass and volume. Our privacy preserving optics enable applications such as depth sensing, full-body motion tracking, people counting, blob detection and privacy preserving face recognition. While we demonstrate applications on macro-scale devices (smartphones, webcams, etc.) our theory has impact for smaller devices.

  12. Earth observations taken from shuttle orbiter Discovery on STS-70 mission

    NASA Image and Video Library

    1995-07-21

    STS070-717-011 (13-22 JULY 1995) --- Volcanic landscapes with a thin dusting of snow appear in this near-vertical view of the dry, high spine of the Andes Mountains at around 28 degrees south latitude. Strong westerly winds (from left) have blown the snow off the highest volcanic peaks (center and bottom): many of these peaks rise higher than 20,000 feet. A small, dry lake appears top right, the white color derived from salts. The border between Argentina and Chile winds from volcano to volcano and passes just left of the small blue lake (left center). Black lava flows can be detected bottom right. The larger area of brown-pink rocks (bottom rock) is also an area of volcanic rocks, of a type known as ash flow tuffs which are violently extruded, often in volumes measured in cubic kilometers.

  13. 40 CFR 1045.635 - What special provisions apply for small-volume engine manufacturers?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false What special provisions apply for small-volume engine manufacturers? 1045.635 Section 1045.635 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...

  14. 40 CFR 1045.635 - What special provisions apply for small-volume engine manufacturers?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false What special provisions apply for small-volume engine manufacturers? 1045.635 Section 1045.635 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...

  15. 40 CFR 1045.635 - What special provisions apply for small-volume engine manufacturers?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false What special provisions apply for small-volume engine manufacturers? 1045.635 Section 1045.635 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...

  16. 40 CFR 1045.635 - What special provisions apply for small-volume engine manufacturers?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false What special provisions apply for small-volume engine manufacturers? 1045.635 Section 1045.635 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...

  17. 40 CFR 86.1823-08 - Durability demonstration procedures for exhaust emissions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) General Compliance Provisions for Control of Air Pollution From New and In... § 86.1801. Eligible small volume manufacturers or small volume test groups may optionally meet the...

  18. 40 CFR 86.1823-08 - Durability demonstration procedures for exhaust emissions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) General Compliance Provisions for Control of Air Pollution From New and In... § 86.1801. Eligible small volume manufacturers or small volume test groups may optionally meet the...

  19. 40 CFR 86.1824-08 - Durability demonstration procedures for evaporative emissions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... for evaporative emissions. Eligible small-volume manufacturers or small-volume test groups may...-based measurements except the bleed emission test. The standard for bleed emissions applies for the full... manufacturer must conduct at least one evaporative emission test at each of the five different mileage points...

  20. 40 CFR 86.1824-08 - Durability demonstration procedures for evaporative emissions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the applicability provisions of § 86.1801. Eligible small volume manufacturers or small volume test... manufacturer must conduct at least one evaporative emission test at each of the five different mileage points... the highest mileage point run during mileage accumulation (e.g. the full useful life mileage...

  1. 40 CFR 86.094-14 - Small-volume manufacturers certification procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES General Provisions for Emission Regulations for 1977 and Later Model Year New Light-Duty Vehicles, Light...-Fueled, Liquefied Petroleum Gas-Fueled and Methanol-Fueled Heavy-Duty Vehicles § 86.094-14 Small-volume...

  2. 40 CFR 1045.635 - What special provisions apply for small-volume engine manufacturers?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false What special provisions apply for small-volume engine manufacturers? 1045.635 Section 1045.635 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...

  3. 40 CFR 86.095-14 - Small-volume manufacturers certification procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-Fueled, Liquefied Petroleum Gas-Fueled and Methanol-Fueled Heavy-Duty Vehicles § 86.095-14 Small-volume... are exempted from the high altitude emission standards. (18) Proof that the manufacturer has obtained... as proof that the manufacturer has obtained or entered an agreement to purchase the insurance policy...

  4. 40 CFR 86.095-14 - Small-volume manufacturers certification procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-Fueled, Liquefied Petroleum Gas-Fueled and Methanol-Fueled Heavy-Duty Vehicles § 86.095-14 Small-volume... are exempted from the high altitude emission standards. (18) Proof that the manufacturer has obtained... as proof that the manufacturer has obtained or entered an agreement to purchase the insurance policy...

  5. Compilation of 1985 annual reports of the Navy elf (extremely low frequency) communications system ecological monitoring program. Volume 2. Tabs D-G. Annual progress report, January-December 1985

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Band, R.N.; Snider, R.J.; Snider, R.M.

    1986-07-01

    This volume consists of the following reports: Soil Amoeba; Soil and Litter Arthropoda and Earthworm Studies; Biological Studies on Pollinating Insects: Megachilid Bees; Small Vertebrates: Small Mammals and Nesting Birds.

  6. 40 CFR 86.1826-01 - Assigned deterioration factors for small-volume manufacturers and small-volume test groups.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... applying deterioration factors. Manufacturers may use assigned deterioration factors that the Administrator determines and prescribes. (1) The deterioration factors will be the Administrator's estimate, periodically... using the industry-wide database of previously completed durability data vehicles or engines used for...

  7. Detection of atomic scale changes in the free volume void size of three-dimensional colorectal cancer cell culture using positron annihilation lifetime spectroscopy.

    PubMed

    Axpe, Eneko; Lopez-Euba, Tamara; Castellanos-Rubio, Ainara; Merida, David; Garcia, Jose Angel; Plaza-Izurieta, Leticia; Fernandez-Jimenez, Nora; Plazaola, Fernando; Bilbao, Jose Ramon

    2014-01-01

    Positron annihilation lifetime spectroscopy (PALS) provides a direct measurement of the free volume void sizes in polymers and biological systems. This free volume is critical in explaining and understanding physical and mechanical properties of polymers. Moreover, PALS has been recently proposed as a potential tool in detecting cancer at early stages, probing the differences in the subnanometer scale free volume voids between cancerous/healthy skin samples of the same patient. Despite several investigations on free volume in complex cancerous tissues, no positron annihilation studies of living cancer cell cultures have been reported. We demonstrate that PALS can be applied to the study in human living 3D cell cultures. The technique is also capable to detect atomic scale changes in the size of the free volume voids due to the biological responses to TGF-β. PALS may be developed to characterize the effect of different culture conditions in the free volume voids of cells grown in vitro.

  8. Detection of Atomic Scale Changes in the Free Volume Void Size of Three-Dimensional Colorectal Cancer Cell Culture Using Positron Annihilation Lifetime Spectroscopy

    PubMed Central

    Castellanos-Rubio, Ainara; Merida, David; Garcia, Jose Angel; Plaza-Izurieta, Leticia; Fernandez-Jimenez, Nora; Plazaola, Fernando; Bilbao, Jose Ramon

    2014-01-01

    Positron annihilation lifetime spectroscopy (PALS) provides a direct measurement of the free volume void sizes in polymers and biological systems. This free volume is critical in explaining and understanding physical and mechanical properties of polymers. Moreover, PALS has been recently proposed as a potential tool in detecting cancer at early stages, probing the differences in the subnanometer scale free volume voids between cancerous/healthy skin samples of the same patient. Despite several investigations on free volume in complex cancerous tissues, no positron annihilation studies of living cancer cell cultures have been reported. We demonstrate that PALS can be applied to the study in human living 3D cell cultures. The technique is also capable to detect atomic scale changes in the size of the free volume voids due to the biological responses to TGF-β. PALS may be developed to characterize the effect of different culture conditions in the free volume voids of cells grown in vitro. PMID:24392097

  9. Role of New Functional MRI Techniques in the Diagnosis, Staging, and Followup of Gynecological Cancer: Comparison with PET-CT

    PubMed Central

    Alvarez Moreno, Elena; Jimenez de la Peña, Mar; Cano Alonso, Raquel

    2012-01-01

    Recent developments in diagnostic imaging techniques have magnified the role and potential of both MRI and PET-CT in female pelvic imaging. This article reviews the techniques and clinical applications of new functional MRI (fMRI) including diffusion-weighted MRI (DWI), dynamic contrast-enhanced (DCE)-MRI, comparing with PET-CT. These new emerging provide not only anatomic but also functional imaging, allowing detection of small volumes of active tumor at diagnosis and early disease relapse, which may not result in detectable morphological changes at conventional imaging. This information is useful in distinguishing between recurrent/residual tumor and post-treatment changes and assessing treatment response, with a clear impact on patient management. Both PET-CT and now fMRI have proved to be very valuable tools for evaluation of gynecologic tumors. Most papers try to compare these techniques, but in our experience both are complementary in management of these patients. Meanwhile PET-CT is superior in diagnosis of ganglionar disease; fMRI presents higher accuracy in local preoperative staging. Both techniques can be used as biomarkers of tumor response and present high accuracy in diagnosis of local recurrence and peritoneal dissemination, with complementary roles depending on histological type, anatomic location and tumoral volume. PMID:22315683

  10. Experimental evidence for negative turgor pressure in small leaf cells of Robinia pseudoacacia L versus large cells of Metasequoia glyptostroboides Hu et W.C. Cheng. 2. Höfler diagrams below the volume of zero turgor and the theoretical implication for pressure-volume curves of living cells.

    PubMed

    Yang, Dongmei; Li, Junhui; Ding, Yiting; Tyree, Melvin T

    2017-03-01

    The physiological advantages of negative turgor pressure, P t , in leaf cells are water saving and homeostasis of reactants. This paper advances methods for detecting the occurrence of negative P t in leaves. Biomechanical models of pressure-volume (PV) curves predict that negative P t does not change the linearity of PV curve plots of inverse balance pressure, P B , versus relative water loss, but it does predict changes in either the y-intercept or the x-intercept of the plots depending on where cell collapse occurs in the P B domain because of negative P t . PV curve analysis of Robinia leaves revealed a shift in the x-intercept (x-axis is relative water loss) of PV curves, caused by negative P t of palisade cells. The low x-intercept of the PV curve was explained by the non-collapse of palisade cells in Robinia in the P B domain. Non-collapse means that P t smoothly falls from positive to negative values with decreasing cell volume without a dramatic change in slope. The magnitude of negative turgor in non-collapsing living cells was as low as -1.3 MPa and the relative volume of the non-collapsing cell equaled 58% of the total leaf cell volume. This study adds to the growing evidence for negative P t . © 2016 John Wiley & Sons Ltd.

  11. Improving the accuracy of ionization chamber dosimetry in small megavoltage x-ray fields

    NASA Astrophysics Data System (ADS)

    McNiven, Andrea L.

    The dosimetry of small x-ray fields is difficult, but important, in many radiation therapy delivery methods. The accuracy of ion chambers for small field applications, however, is limited due to the relatively large size of the chamber with respect to the field size, leading to partial volume effects, lateral electronic disequilibrium and calibration difficulties. The goal of this dissertation was to investigate the use of ionization chambers for the purpose of dosimetry in small megavoltage photon beams with the aim of improving clinical dose measurements in stereotactic radiotherapy and helical tomotherapy. A new method for the direct determination of the sensitive volume of small-volume ion chambers using micro computed tomography (muCT) was investigated using four nominally identical small-volume (0.56 cm3) cylindrical ion chambers. Agreement between their measured relative volume and ionization measurements (within 2%) demonstrated the feasibility of volume determination through muCT. Cavity-gas calibration coefficients were also determined, demonstrating the promise for accurate ion chamber calibration based partially on muCT. The accuracy of relative dose factor measurements in 6MV stereotactic x-ray fields (5 to 40mm diameter) was investigated using a set of prototype plane-parallel ionization chambers (diameters of 2, 4, 10 and 20mm). Chamber and field size specific correction factors ( CSFQ ), that account for perturbation of the secondary electron fluence, were calculated using Monte Carlo simulation methods (BEAM/EGSnrc simulations). These correction factors (e.g. CSFQ = 1.76 (2mm chamber, 5mm field) allow for accurate relative dose factor (RDF) measurement when applied to ionization readings, under conditions of electronic disequilibrium. With respect to the dosimetry of helical tomotherapy, a novel application of the ion chambers was developed to characterize the fan beam size and effective dose rate. Characterization was based on an adaptation of the computed tomography dose index (CTDI), a concept normally used in diagnostic radiology. This involved experimental determination of the fan beam thickness using the ion chambers to acquire fan beam profiles and extrapolation to a 'zero-size' detector. In conclusion, improvements have been made in the accuracy of small field dosimetry measurements in stereotactic radiotherapy and helical tomotherapy. This was completed through introduction of an original technique involving micro-CT imaging for sensitive volume determination and potentially ion chamber calibration coefficients, the use of appropriate Monte Carlo derived correction factors for RDF measurement, and the exploitation of the partial volume effect for helical tomotherapy fan beam dosimetry. With improved dosimetry for a wide range of challenging small x-ray field situations, it is expected that the patient's radiation safety will be maintained, and that clinical trials will adopt calibration protocols specialized for modern radiotherapy with small fields or beamlets. Keywords. radiation therapy, ionization chambers, small field dosimetry, stereotactic radiotherapy, helical tomotherapy, micro-CT.

  12. Measuring pedestrian volumes and conflicts. Volume III, Measuring pedestrian volumes : a users manual

    DOT National Transportation Integrated Search

    1988-03-01

    Users of the manual are expected to be in divisions responsible for pedestrian safety in cities, counties, and other jurisdictions. The users manual outlines a step-by-step procedure to measure pedestrian volumes using small count intervals. Appendix...

  13. Identification of extracellular miRNA in archived serum samples by next-generation sequencing from RNA extracted using multiple methods.

    PubMed

    Gautam, Aarti; Kumar, Raina; Dimitrov, George; Hoke, Allison; Hammamieh, Rasha; Jett, Marti

    2016-10-01

    miRNAs act as important regulators of gene expression by promoting mRNA degradation or by attenuating protein translation. Since miRNAs are stably expressed in bodily fluids, there is growing interest in profiling these miRNAs, as it is minimally invasive and cost-effective as a diagnostic matrix. A technical hurdle in studying miRNA dynamics is the ability to reliably extract miRNA as small sample volumes and low RNA abundance create challenges for extraction and downstream applications. The purpose of this study was to develop a pipeline for the recovery of miRNA using small volumes of archived serum samples. The RNA was extracted employing several widely utilized RNA isolation kits/methods with and without addition of a carrier. The small RNA library preparation was carried out using Illumina TruSeq small RNA kit and sequencing was carried out using Illumina platform. A fraction of five microliters of total RNA was used for library preparation as quantification is below the detection limit. We were able to profile miRNA levels in serum from all the methods tested. We found out that addition of nucleic acid based carrier molecules had higher numbers of processed reads but it did not enhance the mapping of any miRBase annotated sequences. However, some of the extraction procedures offer certain advantages: RNA extracted by TRIzol seemed to align to the miRBase best; extractions using TRIzol with carrier yielded higher miRNA-to-small RNA ratios. Nuclease free glycogen can be carrier of choice for miRNA sequencing. Our findings illustrate that miRNA extraction and quantification is influenced by the choice of methodologies. Addition of nucleic acid- based carrier molecules during extraction procedure is not a good choice when assaying miRNA using sequencing. The careful selection of an extraction method permits the archived serum samples to become valuable resources for high-throughput applications.

  14. Hollow fibers for compact infrared gas sensors

    NASA Astrophysics Data System (ADS)

    Lambrecht, A.; Hartwig, S.; Herbst, J.; Wöllenstein, J.

    2008-02-01

    Hollow fibers can be used for compact infrared gas sensors. The guided light is absorbed by the gas introduced into the hollow core. High sensitivity and a very small sampling volume can be achieved depending on fiber parameters i.e. attenuation, flexibility, and gas exchange rates. Different types of infrared hollow fibers including photonic bandgap fibers were characterized using quantum cascade lasers and thermal radiation sources. Obtained data are compared with available product specifications. Measurements with a compact fiber based ethanol sensor are compared with a system simulation. First results on the detection of trace amounts of the explosive material TATP using hollow fibers and QCL will be shown.

  15. Functionalized Gold Nanoparticles and Their Biomedical Applications

    PubMed Central

    Tiwari, Pooja M.; Vig, Komal; Dennis, Vida A.; Singh, Shree R.

    2011-01-01

    Metal nanoparticles are being extensively used in various biomedical applications due to their small size to volume ratio and extensive thermal stability. Gold nanoparticles (GNPs) are an obvious choice due to their amenability of synthesis and functionalization, less toxicity and ease of detection. The present review focuses on various methods of functionalization of GNPs and their applications in biomedical research. Functionalization facilitates targeted delivery of these nanoparticles to various cell types, bioimaging, gene delivery, drug delivery and other therapeutic and diagnostic applications. This review is an amalgamation of recent advances in the field of functionalization of gold nanoparticles and their potential applications in the field of medicine and biology. PMID:28348279

  16. SAR studies in the Yuma Desert, Arizona: Sand penetration, geology, and the detection of military ordnance debris

    USGS Publications Warehouse

    Schaber, G.G.

    1999-01-01

    Synthetic Aperture Radar (SAR) images acquired over part of the Yuma Desert in southwestern Arizona demonstrate the ability of C-band (5.7-cm wavelength), L-band (24.5 cm), and P-band (68 cm) AIRSAR signals to backscatter from increasingly greater depths reaching several meters in blow sand and sandy alluvium. AIRSAR images obtained within the Barry M. Goldwater Bombing and Gunnery Range near Yuma, Arizona, show a total reversal of C- and P-band backscatter contrast (image tone) for three distinct geologic units. This phenomenon results from an increasingly greater depth of radar imaging with increasing radar wavelength. In the case of sandy- and small pebble-alluvium surfaces mantled by up to several meters of blow sand, backscatter increases directly with SAR wavelength as a result of volume scattering from a calcic soil horizon at shallow depth and by volume scattering from the root mounds of healthy desert vegetation that locally stabilize blow sand. AIRSAR images obtained within the military range are also shown to be useful for detecting metallic military ordnance debris that is located either at the surface or covered by tens of centimeters to several meters of blow sand. The degree of detectability of this ordnance increases with SAR wavelength and is clearly maximized on P-band images that are processed in the cross-polarized mode (HV). This effect is attributed to maximum signal penetration at P-band and the enhanced PHV image contrast between the radar-bright ordnance debris and the radar-dark sandy desert. This article focuses on the interpretation of high resolution AIRSAR images but also Compares these airborne SAR images with those acquired from spacecraft sensors such as ERS-SAR and Space Radar Laboratory (SIR-C/X-SAR).Synthetic Aperture Radar (SAR) images acquired over part of the Yuma Desert in southwestern Arizona demonstrate the ability of C-band (5.7-cm wavelength), L-band (24.5 cm), and P-band (68 cm) AIRSAR signals to backscatter from increasingly greater depths reaching several meters in blow sand and sandy alluvium. AIRSAR images obtained within the Barry M. Goldwater Bombing and Gunnery Range near Yuma, Arizona, show a total reversal of C- and P-band backscatter contrast (image tone) for three distinct geologic units. This phenomenon results from an increasingly greater depth of radar imaging with increasing radar wavelength. In the case of sandy- and small pebble-alluvium surfaces mantled by up to several meters of blow sand, backscatter increases directly with SAR wavelength as a result of volume scattering from a calcic soil horizon at shallow depth and by volume scattering from the root mounds of healthy desert vegetation that locally stabilize blow sand. AIRSAR images obtained within the military range are also shown to be useful for detecting metallic military ordnance debris that is located either at the surface or covered by tens of centimeters to several meters of blow sand. The degree of detectability of this ordnance increases with SAR wavelength and is clearly maximized on P-band images that are processed in the cross-polarized mode (HV). This effect is attributed to maximum signal penetration at P-band and the enhanced PHV image contrast between the radar-bright ordnance debris and the radar-dark sandy desert. This article focuses on the interpretation of high resolution AIRSAR images but also compares these airborne SAR images with those acquired from spacecraft sensors such as ERS-SAR and Space Radar Laboratory (SIR-C/X-SAR).

  17. Modern Sorters for Soil Segregation on Large Scale Remediation Projects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shonka, J.J.; Kelley, J.E.; O'Brien, J.M.

    2008-01-15

    In the mid-1940's, Dr. C. Lapointe developed a Geiger tube based uranium ore scanner and picker to replace hand-cobbing. In the 1990's, a modern version of the Lapointe Picker for soil sorting was developed around the need to clean the Johnston Atoll of plutonium. It worked well with sand, but these systems are ineffective with soil, especially with wet conditions. Additionally, several other constraints limited throughput. Slow moving belts and thin layers of material on the belt coupled with the use of multiple small detectors and small sorting gates make these systems ineffective for high throughput. Soil sorting of clay-bearingmore » soils and building debris requires a new look at both the material handling equipment, and the radiation detection methodology. A new class of Super-Sorters has attained throughput of one hundred times that of the old designs. Higher throughput means shorter schedules which reduce costs substantially. The planning, cost, implementation, and other site considerations for these new Super-Sorters are discussed. Modern soil segregation was developed by Ed Bramlitt of the Defense Nuclear Agency for clean up at Johnston Atoll. The process eventually became the Segmented Gate System (SGS). This system uses an array of small sodium iodide (NaI) detectors, each viewing a small volume (segment), that control a gate. The volume in the gate is approximately one kg. This system works well when the material to be processed is sand; however, when the material is wet and sticky (soils with clays) the system has difficulty moving the material through the gates. Super-Sorters are a new class of machine designed to take advantage of high throughput aggregate processing conveyors, large acquisition volumes, and large NaI detectors using gamma spectroscopy. By using commercially available material handling equipment, the system can attain processing rates of up to 400 metric tons/hr with spectrum acquisition approximately every 0.5 sec, so the acquisition volume is 50 kilograms or less. Smaller sorting volumes can be obtained with lower throughput or by re-sorting the diverted material. This equipment can also handle large objects. The use of spectroscopy systems allows several regions of- interest to be set. Super-Sorters can bring waste processing charges down to less than $30/ metric ton on smaller jobs and can save hundreds of dollars per metric ton in disposal charges. The largest effect on the overall project cost occurs during planning and implementation. The overall goal is reduction of the length of the project, which dictates the most efficient soil processing. With all sorting systems the parameters that need to be accounted for are matrix type, soil feed rate, soil pre-processing, site conditions, and regulatory issues. The soil matrix and its ability to flow are extremely crucial to operations. It is also important to consider that as conditions change (i.e., moisture), the flowability of the soil matrix will change. Many soil parameters have to be considered: cohesive strength, internal and wall friction, permeability, and bulk density as a function of consolidating pressure. Clay bearing soils have very low permeability and high cohesive strength which makes them difficult to process, especially when wet. Soil feed speed is dependent on the equipment present and the ability to move the soil in the Super-Sorter processing area. When a Super-Sorter is running at 400 metric tons per hour it is difficult to feed the system. As an example, front-end loaders with large buckets would move approximately 5-10 metric tons of material, and 400 metric tons per hour would require 50-100 bucket-loads per hour to attain. Because the flowability of the soil matrix is important, poor material is often pre-processed before it is added to the feed hopper of the 'survey' conveyor. This pre-processing can consist of a 'grizzly' to remove large objects from the soil matrix, followed screening plant to prepare the soil so that it feeds well. Hydrated lime can be added to improve material properties. Site conditions (site area, typical weather conditions, etc.) also play a large part in project planning. Downtime lengthens project schedule and costs. The system must be configured to handle weather conditions or other variables that affect throughput. The largest single factor that plays into the project design is the regulatory environment. Before a sorter can be utilized, an averaging mass must be established by the regulator(s). There currently are no standards or guidelines in this area. The differences between acquisition mass and averaging mass are very important. The acquisition mass is defined based on the acquisition time and the geometry of the detectors. The averaging mass can then be as small as the acquisition mass or as large as several hundred tons (the averaging mass is simply the sum of a number of acquisitions). It is important to define volumetric limits and any required point-source limits. Super-Sorters handle both of these types of limits simultaneously. The minimum detectable activity for Super- Sorters is a function of speed. The chart below illustrates the detection confidence level for a 0.1 {mu}Ci point source of Ra-226 vs alarm point for three different sorter process rates. The minimal detection activity and diversion volume for a Super-Sorter is also a function of the acquisition mass. The curves were collected using a 0-15 kg acquisition mass. Diversion volumes ranged from 20-30 kg for a point source diversion. Soil Super-Sorters should be considered for every D and D project where it is desirable to reduce the waste stream. A volume reduction of 1:1000 can be gained for each pass through a modern sorter, resulting in significant savings in disposal costs.« less

  18. Brain structural changes and their correlation with vascular disease in type 2 diabetes mellitus patients: a voxel-based morphometric study.

    PubMed

    Wang, Chunxia; Fu, Kailiang; Liu, Huaijun; Xing, Fei; Zhang, Songyun

    2014-08-15

    Voxel-based morphometry has been used in the study of alterations in brain structure in type 1 diabetes mellitus patients. These changes are associated with clinical indices. The age at onset, pathogenesis, and treatment of type 1 diabetes mellitus are different from those for type 2 diabetes mellitus. Thus, type 1 and type 2 diabetes mellitus may have different impacts on brain structure. Only a few studies of the alterations in brain structure in type 2 diabetes mellitus patients using voxel-based morphometry have been conducted, with inconsistent results. We detected subtle changes in the brain structure of 23 cases of type 2 diabetes mellitus, and demonstrated that there was no significant difference between the total volume of gray and white matter of the brain of type 2 diabetes mellitus patients and that in controls. Regional atrophy of gray matter mainly occurred in the right temporal and left occipital cortex, while regional atrophy of white matter involved the right temporal lobe and the right cerebellar hemisphere. The ankle-brachial index in patients with type 2 diabetes mellitus strongly correlated with the volume of brain regions in the default mode network. The ankle-brachial index, followed by the level of glycosylated hemoglobin, most strongly correlated with the volume of gray matter in the right temporal lobe. These data suggest that voxel-based morphometry could detect small structural changes in patients with type 2 diabetes mellitus. Early macrovascular atherosclerosis may play a crucial role in subtle brain atrophy in type 2 diabetes mellitus patients, with chronic hyperglycemia playing a lesser role.

  19. Concentration of Enteroviruses, Adenoviruses, and Noroviruses from Drinking Water by Use of Glass Wool Filters▿

    PubMed Central

    Lambertini, Elisabetta; Spencer, Susan K.; Bertz, Phillip D.; Loge, Frank J.; Kieke, Burney A.; Borchardt, Mark A.

    2008-01-01

    Available filtration methods to concentrate waterborne viruses are either too costly for studies requiring large numbers of samples, limited to small sample volumes, or not very portable for routine field applications. Sodocalcic glass wool filtration is a cost-effective and easy-to-use method to retain viruses, but its efficiency and reliability are not adequately understood. This study evaluated glass wool filter performance to concentrate the four viruses on the U.S. Environmental Protection Agency contaminant candidate list, i.e., coxsackievirus, echovirus, norovirus, and adenovirus, as well as poliovirus. Total virus numbers recovered were measured by quantitative reverse transcription-PCR (qRT-PCR); infectious polioviruses were quantified by integrated cell culture (ICC)-qRT-PCR. Recovery efficiencies averaged 70% for poliovirus, 14% for coxsackievirus B5, 19% for echovirus 18, 21% for adenovirus 41, and 29% for norovirus. Virus strain and water matrix affected recovery, with significant interaction between the two variables. Optimal recovery was obtained at pH 6.5. No evidence was found that water volume, filtration rate, and number of viruses seeded influenced recovery. The method was successful in detecting indigenous viruses in municipal wells in Wisconsin. Long-term continuous filtration retained viruses sufficiently for their detection for up to 16 days after seeding for qRT-PCR and up to 30 days for ICC-qRT-PCR. Glass wool filtration is suitable for large-volume samples (1,000 liters) collected at high filtration rates (4 liters min−1), and its low cost makes it advantageous for studies requiring large numbers of samples. PMID:18359827

  20. Liquid chromatography/Fourier transform IR spectrometry interface flow cell

    DOEpatents

    Johnson, Charles C.; Taylor, Larry T.

    1986-01-01

    A zero dead volume (ZDV) microbore high performance liquid chromatography (.mu.HPLC)/Fourier transform infrared (FTIR) interface flow cell includes an IR transparent crystal having a small diameter bore therein through which a sample liquid is passed. The interface flow cell further includes a metal holder in combination with a pair of inner, compressible seals for directly coupling the thus configured spectrometric flow cell to the outlet of a .mu.HPLC column end fitting to minimize the transfer volume of the effluents exiting the .mu.HPLC column which exhibit excellent flow characteristics due to the essentially unencumbered, open-flow design. The IR beam passes transverse to the sample flow through the circular bore within the IR transparent crystal, which is preferably comprised of potassium bromide (KBr) or calcium fluoride (CaF.sub.2), so as to minimize interference patterns and vignetting encountered in conventional parallel-plate IR cells. The long IR beam pathlength and lensing effect of the circular cross-section of the sample volume in combination with the refractive index differences between the solvent and the transparent crystal serve to focus the IR beam in enhancing sample detection sensitivity by an order of magnitude.

  1. Liquid chromatography/Fourier transform IR spectrometry interface flow cell

    DOEpatents

    Johnson, C.C.; Taylor, L.T.

    1985-01-04

    A zero dead volume (ZDV) microbore high performance liquid chromatography (..mu.. HPLC)/Fourier transform infrared (FTIR) interface flow cell includes an IR transparent crystal having a small diameter bore therein through which a sample liquid is passed. The interface flow cell further includes a metal holder in combination with a pair of inner, compressible seals for directly coupling the thus configured spectrometric flow cell to the outlet of a ..mu.. HPLC column end fitting to minimize the transfer volume of the effluents exiting the ..mu.. HPLC column which exhibit excellent flow characteristics due to the essentially unencumbered, open-flow design. The IR beam passes transverse to the sample flow through the circular bore within the IR transparent crystal, which is preferably comprised of potassium bromide (KBr) or calcium fluoride (CaF/sub 2/), so as to minimize interference patterns and vignetting encountered in conventional parallel-plate IR cells. The long IR beam pathlength and lensing effect of the circular cross-section of the sample volume in combination with the refractive index differences between the solvent and the transparent crystal serve to focus the IR beam in enhancing sample detection sensitivity by an order of magnitude.

  2. Electroosmotic flow analysis of a branched U-turn nanofluidic device.

    PubMed

    Parikesit, Gea O F; Markesteijn, Anton P; Kutchoukov, Vladimir G; Piciu, Oana; Bossche, Andre; Westerweel, Jerry; Garini, Yuval; Young, Ian T

    2005-10-01

    In this paper, we present the analysis of electroosmotic flow in a branched -turn nanofluidic device, which we developed for detection and sorting of single molecules. The device, where the channel depth is only 150 nm, is designed to optically detect fluorescence from a volume as small as 270 attolitres (al) with a common wide-field fluorescent setup. We use distilled water as the liquid, in which we dilute 110 nm fluorescent beads employed as tracer-particles. Quantitative imaging is used to characterize the pathlines and velocity distribution of the electroosmotic flow in the device. Due to the device's complex geometry, the electroosmotic flow cannot be solved analytically. Therefore we use numerical flow simulation to model our device. Our results show that the deviation between measured and simulated data can be explained by the measured Brownian motion of the tracer-particles, which was not incorporated in the simulation.

  3. Applied Imagistics of Ischaemic Heart a Survey. From the Epidemiology of Stable Angina In Order to Better Prevent Sudden Cardiac Death

    NASA Astrophysics Data System (ADS)

    Petruse, Radu Emanuil; Batâr, Sergiu; Cojan, Adela; Maniţiu, Ioan

    2014-11-01

    Coronary computed tomography angiography (CCTA) allows coronary artery visualization and the detection of coronary stenoses. In addition; it has been suggested as a novel, noninvasive modality for coronary atherosclerotic plaque detection, characterization, and quantification. Accurate identification of coronary plaques is challenging, especially for the noncalcified plaques, due to many factors such as the small size of coronary arteries, reconstruction artifacts caused by irregular heartbeats, beam hardening, and partial volume averaging. The development of 16, 32, 64 and the latest 320 row multidetector CT not only increases the spatial and the temporal resolution significantly, but also increases the number of images to be interpreted by radiologists substantially. Radiologists have to visually examine each coronary artery for suspicious stenosis using visualization tools such as multiplanar reformatting (MPR) and curved planar reformatting (CPR) provided by the review workstation in clinical practice

  4. Dynamic Bayesian network modeling for longitudinal brain morphometry

    PubMed Central

    Chen, Rong; Resnick, Susan M; Davatzikos, Christos; Herskovits, Edward H

    2011-01-01

    Identifying interactions among brain regions from structural magnetic-resonance images presents one of the major challenges in computational neuroanatomy. We propose a Bayesian data-mining approach to the detection of longitudinal morphological changes in the human brain. Our method uses a dynamic Bayesian network to represent evolving inter-regional dependencies. The major advantage of dynamic Bayesian network modeling is that it can represent complicated interactions among temporal processes. We validated our approach by analyzing a simulated atrophy study, and found that this approach requires only a small number of samples to detect the ground-truth temporal model. We further applied dynamic Bayesian network modeling to a longitudinal study of normal aging and mild cognitive impairment — the Baltimore Longitudinal Study of Aging. We found that interactions among regional volume-change rates for the mild cognitive impairment group are different from those for the normal-aging group. PMID:21963916

  5. Development of a Photothermal Absorbance Detector for Use with Microfluidic Devices

    PubMed Central

    Dennis, Patty J.; Ferguson Welch, Erin R.; Alarie, Jean Pierre; Ramsey, J. Michael; Jorgenson, James W.

    2010-01-01

    The development of a photothermal absorbance detector for use with microfluidic devices is described. Unlike thermooptical techniques that rely on measuring refractive index changes, the solution viscosity is probed by continuously monitoring solution conductivity. Platinum electrodes microfabricated on a quartz substrate and bonded to a substrate containing the microchannels enable contact conductivity measurements. The effects of excitation frequency and voltage, electrode spacing, laser power, and laser modulation (chopping) frequency were evaluated experimentally. In the current configuration a limit of detection of 5 nM for DABSYL-tagged glucosamine was obtained using long injections (to give flat-topped peaks). This corresponds to an absorbance of 4.4 × 10−7 AU. Separation and detection of DABSYL-tagged glycine, proline, and tryptophan is also shown to demonstrate the feasibility of the method. In addition, simulations were used to investigate the applicability of the technique to small volume platforms. PMID:20411923

  6. A rapid high-performance liquid-chromatographic method for simultaneously determining the concentrations of TFM and Bayer 73 in water during lampricide treatments

    USGS Publications Warehouse

    Dawson, V.K.

    1982-01-01

    The high-performance liquid-chromatography (HPLC) procedure requires only minutes per sample, is specific, and is relatively sensitive (limit of detection 18 disposable cartridge. The cartridge adsorbs and retains both the lampricides and the internal standard. The quantitative elution of the three chemicals from the cartridge with a small volume of methanol effectively concentrates the sample and provides sample cleanup. The methanol extract is then analyzed directly by HPLC on an MCH 10 reverse phase column by using a methanol:0.01 mol/L acetate buffer (87:13, v:v) as the mobile phase at 2 mL/min and detected by ultraviolet spectrophotometry at 330 (or 254) nm. A microprocessor data system further facilitates the procedure by quantifying off-scale peaks and yielding results directly in units of concentration (mg/L).

  7. [Study on remote sensing of methane leakage using a tunable diode laser].

    PubMed

    Fan, Hong; Gao, Xiao-Ming; Bao, Jian; Wang, Xia; Huang, Teng; Huang, Wei; Cao, Zhen-Song; Zhang, Wei-Jun

    2006-08-01

    The leak of natural gas is not only an economic loss, but also the fountain of danger. Conventional detection techniques of natural gas pipe leak have low efficiency and slow respond time, therefore, it is difficult for them to suit practice application. Optical sensors based on NIR tunable diode laser absorption spectroscopy were widely used because of high sensitivity, small volume and less maintenance. In the present paper, a portable remote sensor of natural gas pipeline leak was reported. The sensor used a ratio of second to first harmonic signals as calibration method, and the results show a good consistency between the concentrations and the ratios of second to first harmonic signals. The effect of different topographic scattering targets on the ratio detection was measured and analyzed. The results show that the ratio of second to first harmonic signals can be used in practical application.

  8. 40 CFR 94.209 - Special provisions for post-manufacture marinizers and small-volume manufacturers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-manufacture marinizers and small-volume manufacturers. 94.209 Section 94.209 Protection of Environment... COMPRESSION-IGNITION ENGINES Certification Provisions § 94.209 Special provisions for post-manufacture... demonstrate one of the following: (1) It is a post-manufacture marinizer and that the base engines used for...

  9. Measuring Very Small Quantities: Fascinating Suggestions for Math or Science.

    ERIC Educational Resources Information Center

    Thompson, John Taylor

    1989-01-01

    Described are several activities for teaching children to determine mass and volume. Included are the masses of a water drop and a grain of rice; the volume of a water drop and small solids; and measuring the width of a hair. Procedures and materials for the activities are discussed. (CW)

  10. Basics of Sterile Compounding: Particulate Matter.

    PubMed

    Akers, Michael J

    2017-01-01

    This article focuses on the requirements for particulate matter in sterile products. Topics include particles and quality, particulate matter standards (large- and small-volume injectables), development of the small-volume injectable test, electronic (light obscuration) and microscope testing, and special requirements for particulate matter in biopharmaceutical preparations. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  11. 40 CFR 86.1838-01 - Small-volume manufacturer certification procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES General Compliance Provisions for Control of Air Pollution From New and In-Use Light-Duty Vehicles, Light-Duty Trucks, and Complete Otto-Cycle Heavy-Duty Vehicles § 86.1838-01 Small-volume manufacturer...

  12. A Portable Immunoassay Platform for Multiplexed Detection of Biotoxins in Clinical and Environmental Samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Koh, Chung-Yan; Piccini, Matthew Ernest; Schaff, Ulrich Y.

    Multiple cases of attempted bioterrorism events using biotoxins have highlighted the urgent need for tools capable of rapid screening of suspect samples in the field (e.g., mailroom and public events). We present a portable microfluidic device capable of analyzing environmental (e.g., white powder), food (e.g., milk) and clinical (e.g., blood) samples for multiplexed detection of biotoxins. The device is rapid (<15-30 min sample-to-answer), sensitive (< 0.08 pg/mL detection limit for botulinum toxin), multiplexed (up to 64 parallel assays) and capable of analyzing small volume samples (< 20 μL total sample input). The immunoassay approach (SpinDx) is based on binding ofmore » toxins in a sample to antibody-laden capture particles followed by sedimentation of particles through a density-media in a microfluidic disk and quantification using a laser-induced fluorescence detector. A direct, blinded comparison with a gold standard ELISA revealed a 5-fold more sensitive detection limit for botulinum toxin while requiring 250-fold less sample volume and a 30 minute assay time with a near unity correlation. A key advantage of the technique is its compatibility with a variety of sample matrices with no additional sample preparation required. Ultrasensitive quantification has been demonstrated from direct analysis of multiple clinical, environmental and food samples, including white powder, whole blood, saliva, salad dressing, whole milk, peanut butter, half and half, honey, and canned meat. We believe that this device can met an urgent need in screening both potentially exposed people as well as suspicious samples in mail-rooms, airports, public sporting venues and emergency rooms. The general-purpose immunodiagnostics device can also find applications in screening of infectious and systemic diseases or serve as a lab device for conducting rapid immunoassays.« less

  13. Feasibility study of mid-infrared absorption spectroscopy using electrospray ionization

    NASA Astrophysics Data System (ADS)

    Ahmed, Tahsin; Foster, Erick; Bohn, Paul; Howard, Scott

    2016-09-01

    Precise detection of trace amount of molecules, such as the disease biomarkers present in biofluids or explosive residues, requires high sensitivity detection. electrospray ionization-mass spectrometry (ESI-MS) is a common and effective technique for sensitive trace molecular detection in small-volume liquid samples. In ESI-MS, nano-liter volume samples are ionized and aerosolized by ESI, and fed into MS for mass analysis. ESI-MS has proven to be a reliable ionization technique for coupling liquid phase separations like liquid chromatography (LC) and capillary zone electrophoresis (CE) with the highly specific resolving power of MS. While CE and ESI can be performed on a microfluidic chip having a footprint of a few cm2, MS is typically at least 100 times bigger in size than a micro-chip. A reduced size, weight, and power profile would enable semi-portable applications in forensics, environmental monitoring, defense, and biological/pharmaceutical applications. To achieve this goal, we present an initial study evaluating the use of mid-infrared absorption spectroscopy (MIRAS) in place of MS to create a ESI-MIRAS system. To establish feasibility, we perform ESI-MIRAS on phospholipid samples, which have been previously demonstrated to be separable by CE. Phospholipids are biomarkers of degenerative neurological, kidney, and bone diseases and can be found in biofluids such as blood, urine and cerebrospinal fluid. To establish sensitivity limits, calibration samples of 100 μM concentration are electrospray deposited on to a grounded Si wafer for different times (1 minutes to 4 minutes with a 1 minute step). The minimum detectable concentration-time product, where a FTIR globar is used as the MIR source, is found 200 μM·s.

  14. Delineating Concealed Faults within Cogdell Oil Field via Earthquake Detection

    NASA Astrophysics Data System (ADS)

    Aiken, C.; Walter, J. I.; Brudzinski, M.; Skoumal, R.; Savvaidis, A.; Frohlich, C.; Borgfeldt, T.; Dotray, P.

    2016-12-01

    Cogdell oil field, located within the Permian Basin of western Texas, has experienced several earthquakes ranging from magnitude 1.7 to 4.6, most of which were recorded since 2006. Using the Earthscope USArray, Gan and Frohlich [2013] relocated some of these events and found a positive correlation in the timing of increased earthquake activity and increased CO2 injection volume. However, focal depths of these earthquakes are unknown due to 70 km station spacing of the USArray. Accurate focal depths as well as new detections can delineate subsurface faults and establish whether earthquakes are occurring in the shallow sediments or in the deeper basement. To delineate subsurface fault(s) in this region, we first detect earthquakes not currently listed in the USGS catalog by applying continuous waveform-template matching algorithms to multiple seismic data sets. We utilize seismic data spanning the time frame of 2006 to 2016 - which includes data from the U.S. Geological Survey Global Seismographic Network, the USArray, and the Sweetwater, TX broadband and nodal array located 20-40 km away. The catalog of earthquakes enhanced by template matching reveals events that were well recorded by the large-N Sweetwater array, so we are experimenting with strategies for optimizing template matching using different configurations of many stations. Since earthquake activity in the Cogdell oil field is on-going (a magnitude 2.6 occurred on May 29, 2016), a temporary deployment of TexNet seismometers has been planned for the immediate vicinity of Cogdell oil field in August 2016. Results on focal depths and detection of small magnitude events are pending this small local network deployment.

  15. Accurate detection for a wide range of mutation and editing sites of microRNAs from small RNA high-throughput sequencing profiles

    PubMed Central

    Zheng, Yun; Ji, Bo; Song, Renhua; Wang, Shengpeng; Li, Ting; Zhang, Xiaotuo; Chen, Kun; Li, Tianqing; Li, Jinyan

    2016-01-01

    Various types of mutation and editing (M/E) events in microRNAs (miRNAs) can change the stabilities of pre-miRNAs and/or complementarities between miRNAs and their targets. Small RNA (sRNA) high-throughput sequencing (HTS) profiles can contain many mutated and edited miRNAs. Systematic detection of miRNA mutation and editing sites from the huge volume of sRNA HTS profiles is computationally difficult, as high sensitivity and low false positive rate (FPR) are both required. We propose a novel method (named MiRME) for an accurate and fast detection of miRNA M/E sites using a progressive sequence alignment approach which refines sensitivity and improves FPR step-by-step. From 70 sRNA HTS profiles with over 1.3 billion reads, MiRME has detected thousands of statistically significant M/E sites, including 3′-editing sites, 57 A-to-I editing sites (of which 32 are novel), as well as some putative non-canonical editing sites. We demonstrated that a few non-canonical editing sites were not resulted from mutations in genome by integrating the analysis of genome HTS profiles of two human cell lines, suggesting the existence of new editing types to further diversify the functions of miRNAs. Compared with six existing studies or methods, MiRME has shown much superior performance for the identification and visualization of the M/E sites of miRNAs from the ever-increasing sRNA HTS profiles. PMID:27229138

  16. Acoustic Detection of Phase Transitions at the Nanoscale

    DOE PAGES

    Vasudevan, Rama K.; Khassaf, Hamidreza; Cao, Ye; ...

    2016-01-25

    On page 478, N. Bassiri-Gharb and co-workers demonstrate acoustic detection in nanoscale volumes by use of an atomic force microscope tip technique. Elastic changes in volume are measured by detecting changes in resonance of the cantilever. Also, the electric field in this case causes a phase transition, which is modeled by Landau theory.

  17. Laser optoacoustic tomography for medical diagnostics: principles

    NASA Astrophysics Data System (ADS)

    Oraevsky, Alexander A.; Esenaliev, Rinat O.; Jacques, Steven L.; Tittel, Frank K.

    1996-04-01

    This paper is to describe principles of laser optoacoustic tomography for medical diagnostics. Two types of imaging modes are presented. The first is the tomography in transmission mode, which utilizes detection of stress transients transmitted from the laser-excited volume toward the depth through thick layers of tissue. The second is the tomography in reflection mode which utilizes detection of stress transients generated in superficial tissue layer and reflected back toward tissue surface. To distinguish the two modes, we have abbreviated them as (1) laser optoacoustic tomography in transmission mode, LOATT, and (2) time-resolved stress detection tomography of light absorption, TRSDTLA, in reflection mode where emphasis is made on high spatial resolution of images. The basis for laser optoacoustic tomography is the time-resolved detection of laser-induced transient stress waves, selectively generated in absorbing tissues of diagnostic interest. Such a technique allows one to visualize absorbed light distribution in turbid biological tissues irradiated by short laser pulses. Laser optoacoustic tomography can be used for detection of tissue pathological changes that result in either increased concentration of various tissue chromophores such as hemoglobin or in development of enhanced microcirculation in diseased tissue. Potential areas of applications are diagnosis of cancer, brain hemorrhages, arterial atherosclerotic plaques, and other diseased tissues. In addition, it can provide feedback information during medical treatments. Both LOATT and TRSDTLA utilize laser excitation of biological tissues and sensitive detection of laser-induced stress waves. Optical selectivity is based upon differences in optical properties of pathologically different tissues. Sensitivity comes from stress generation under irradiation conditions of temporal stress confinement. The use of sensitive wide-band lithium niobate acoustic transducers expands limits of laser optoacoustic tomography. The technology allows us to determine directly temperature distributions in tissues and locate tissues volumes with different absorption. To demonstrate principles of TRSDTLA, experiments were conducted in vivo with mice-model for breast cancer using specially designed front-surface transducers- reflectometers. To present advantages and limitation of LOATT, experiments were performed in phantoms made of gel with polystyrene spheres colored with copper sulfate. Our experimental results and theoretical calculations show that TRSDTLA can be applied for non- invasive histology of layered tissues with in-depth resolution of up to 2 microns. TRSDTLA in acoustic reflection mode is promising for diagnostics of skin and ocular diseases. LOATT in acoustic transmission mode can be applied for detection of small tissue volumes with enhanced absorption located inside organs at the depth of up to 10 cm.

  18. Analysis of lipoprotein profiles of healthy cats by gel-permeation high-performance liquid chromatography

    PubMed Central

    MIZUTANI, Hisashi; SAKO, Toshinori; OKUDA, Hiroko; ARAI, Nobuaki; KURIYAMA, Koji; MORI, Akihiro; YOSHIMURA, Itaru; KOYAMA, Hidekazu

    2016-01-01

    Density gradient ultracentrifugation (DGUC) and gel electrophoresis are conventionally used to obtain lipoprotein profiles of animals. We recently applied high-performance liquid chromatography with a gel permeation column (GP-HPLC) and an on-line dual enzymatic system to dogs for lipoprotein profile analysis. We compared the GP-HPLC with DGUC as a method to obtain a feline lipoprotein profile. The lipoprotein profiles showed large and small peaks, which corresponded to high-density lipoprotein (HDL) and low-density lipoprotein (LDL), respectively, whereas very low-density lipoprotein (VLDL) and chylomicron (CM) were only marginally detected. This profile was very similar to that of dogs reported previously. Healthy cats also had a small amount of cholesterol-rich particles distinct from the normal LDL or HDL profile. There was no difference in lipoprotein profiles between the sexes, but males had a significantly larger LDL particle size (P=0.015). This study shows the feasibility of GP-HPLC for obtaining accurate lipoprotein profiles with small sample volumes and provides valuable reference data for healthy cats that should facilitate diagnoses. PMID:27170431

  19. Pilot-scale demonstration of phytofiltration for treatment of arsenic in New Mexico drinking water.

    PubMed

    Elless, Mark P; Poynton, Charissa Y; Willms, Cari A; Doyle, Mike P; Lopez, Alisa C; Sokkary, Dale A; Ferguson, Bruce W; Blaylock, Michael J

    2005-10-01

    Arsenic contamination of drinking water poses serious health risks to millions of people worldwide. To reduce such risks, the United States Environmental Protection Agency recently lowered the Maximum Contaminant Level for arsenic in drinking water from 50 to 10 microgL(-1). The majority of water systems requiring compliance are small systems that serve less than 10,000 people. Current technologies used to clean arsenic-contaminated water have significant drawbacks, particularly for small treatment systems. In this pilot-scale demonstration, we investigated the use of arsenic-hyperaccumulating ferns to remove arsenic from drinking water using a continuous flow phytofiltration system. Over the course of a 3-month demonstration period, the system consistently produced water having an arsenic concentration less than the detection limit of 2 microgL(-1), at flow rates as high as 1900 L day(-1) for a total treated water volume of approximately 60,000 L. Our results demonstrate that phytofiltration provides the basis for a solar-powered hydroponic technique to enable small-scale cleanup of arsenic-contaminated drinking water.

  20. Automatic Earthquake Detection and Location by Waveform coherency in Alentejo (South Portugal) Using CatchPy

    NASA Astrophysics Data System (ADS)

    Custodio, S.; Matos, C.; Grigoli, F.; Cesca, S.; Heimann, S.; Rio, I.

    2015-12-01

    Seismic data processing is currently undergoing a step change, benefitting from high-volume datasets and advanced computer power. In the last decade, a permanent seismic network of 30 broadband stations, complemented by dense temporary deployments, covered mainland Portugal. This outstanding regional coverage currently enables the computation of a high-resolution image of the seismicity of Portugal, which contributes to fitting together the pieces of the regional seismo-tectonic puzzle. Although traditional manual inspections are valuable to refine automatic results they are impracticable with the big data volumes now available. When conducted alone they are also less objective since the criteria is defined by the analyst. In this work we present CatchPy, a scanning algorithm to detect earthquakes in continuous datasets. Our main goal is to implement an automatic earthquake detection and location routine in order to have a tool to quickly process large data sets, while at the same time detecting low magnitude earthquakes (i.e. lowering the detection threshold). CatchPY is designed to produce an event database that could be easily located using existing location codes (e.g.: Grigoli et al. 2013, 2014). We use CatchPy to perform automatic detection and location of earthquakes that occurred in Alentejo region (South Portugal), taking advantage of a dense seismic network deployed in the region for two years during the DOCTAR experiment. Results show that our automatic procedure is particularly suitable for small aperture networks. The event detection is performed by continuously computing the short-term-average/long-term-average of two different characteristic functions (CFs). For the P phases we used a CF based on the vertical energy trace while for S phases we used a CF based on the maximum eigenvalue of the instantaneous covariance matrix (Vidale 1991). Seismic event location is performed by waveform coherence analysis, scanning different hypocentral coordinates (Grigoli et al. 2013, 2014). The reliability of automatic detections, phase pickings and locations are tested trough the quantitative comparison with manual results. This work is supported by project QuakeLoc, reference: PTDC/GEO-FIQ/3522/2012

  1. Boundary Element Method in a Self-Gravitating Elastic Half-Space and Its Application to Deformation Induced by Magma Chambers

    NASA Astrophysics Data System (ADS)

    Fang, M.; Hager, B. H.

    2014-12-01

    In geophysical applications the boundary element method (BEM) often carries the essential physics in addition to being an efficient numerical scheme. For use of the BEM in a self-gravitating uniform half-space, we made extra effort and succeeded in deriving the fundamental solution analytically in closed-form. A problem that goes deep into the heart of the classic BEM is encountered when we try to apply the new fundamental solution in BEM for deformation field induced by a magma chamber or a fluid-filled reservoir. The central issue of the BEM is the singular integral arising from determination of the boundary values. A widely employed technique is to rescale the singular boundary point into a small finite volume and then shrink it to extract the limits. This operation boils down to the calculation of the so-called C-matrix. Authors in the past take the liberty of either adding or subtracting a small volume. By subtracting a small volume, the C-matrix is (1/2)I on a smooth surface, where I is the identity matrix; by adding a small volume, we arrive at the same C-matrix in the form of I - (1/2)I. This evenness is a result of the spherical symmetry of Kelvin's fundamental solution employed. When the spherical symmetry is broken by gravity, the C-matrix is polarized. And we face the choice between right and wrong, for adding and subtracting a small volume yield different C-matrices. Close examination reveals that both derivations, addition and subtraction of a small volume, are ad hoc. To resolve the issue we revisit the Somigliana identity with a new derivation and careful step-by-step anatomy. The result proves that even though both adding and subtracting a small volume appear to twist the original boundary, only addition essentially modifies the original boundary and consequently modifies the physics of the original problem in a subtle way. The correct procedure is subtraction. We complete a new BEM theory by introducing in full analytical form what we call the singular stress tensor for the fundamental solution. We partition the stress tensor of the fundamental solution into a singular part and a regular part. In this way all singular integrals systematically shift into the easy singular stress tensor. Applications of this new BEM to deformation and gravitational perturbation induced by magma chambers of finite volume will be presented.

  2. Echocardiography underestimates stroke volume and aortic valve area: implications for patients with small-area low-gradient aortic stenosis.

    PubMed

    Chin, Calvin W L; Khaw, Hwan J; Luo, Elton; Tan, Shuwei; White, Audrey C; Newby, David E; Dweck, Marc R

    2014-09-01

    Discordance between small aortic valve area (AVA; < 1.0 cm(2)) and low mean pressure gradient (MPG; < 40 mm Hg) affects a third of patients with moderate or severe aortic stenosis (AS). We hypothesized that this is largely due to inaccurate echocardiographic measurements of the left ventricular outflow tract area (LVOTarea) and stroke volume alongside inconsistencies in recommended thresholds. One hundred thirty-three patients with mild to severe AS and 33 control individuals underwent comprehensive echocardiography and cardiovascular magnetic resonance imaging (MRI). Stroke volume and LVOTarea were calculated using echocardiography and MRI, and the effects on AVA estimation were assessed. The relationship between AVA and MPG measurements was then modelled with nonlinear regression and consistent thresholds for these parameters calculated. Finally the effect of these modified AVA measurements and novel thresholds on the number of patients with small-area low-gradient AS was investigated. Compared with MRI, echocardiography underestimated LVOTarea (n = 40; -0.7 cm(2); 95% confidence interval [CI], -2.6 to 1.3), stroke volumes (-6.5 mL/m(2); 95% CI, -28.9 to 16.0) and consequently, AVA (-0.23 cm(2); 95% CI, -1.01 to 0.59). Moreover, an AVA of 1.0 cm(2) corresponded to MPG of 24 mm Hg based on echocardiographic measurements and 37 mm Hg after correction with MRI-derived stroke volumes. Based on conventional measures, 56 patients had discordant small-area low-gradient AS. Using MRI-derived stroke volumes and the revised thresholds, a 48% reduction in discordance was observed (n = 29). Echocardiography underestimated LVOTarea, stroke volume, and therefore AVA, compared with MRI. The thresholds based on current guidelines were also inconsistent. In combination, these factors explain > 40% of patients with discordant small-area low-gradient AS. Copyright © 2014 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  3. Sensitivity to detect small coronary artery calcium lesions with varying slice thickness using electron beam tomography.

    PubMed

    Mao, Songshou; Child, Janis; Carson, Sivi; Liu, Steve C K; Oudiz, Ronald J; Budoff, Matthew J

    2003-03-01

    To estimate the sensitivity to find small coronary artery calcium lesions with use of different slice widths with electron beam tomography. Two studies were performed. Study 1 utilized double scanning of a stationary cork phantom with three different slice thickness (1.5, 3, and 6 mm). Fifty different calcific lesions (all <20 mm2 in area) fitted in 10 cork coronary arteries were utilized. The calcium foci area, peak value and score were measured and compared. In group 2, 30 patients underwent coronary artery calcium (CAC) screen studies. Each patient was scanned with both 3-mm and 6-mm scan widths in a same study time. Lesions with < 20 mm2 of area of CAC were measured on both 3-mm and 6-mm images. The mean and peak Hounsfield unit measure, and Agatston score were compared between both images. In the cork study, the sensitivity to detect small calcium foci were 96% (48/50), 82% (41/50), and 34% (17/50) in images with 1.5-, 3-, and 6-mm slice thickness, respectively. There is a smaller value in mass, and calcium volume in 6-mm images than 1.5-mm and 3-mm images ( P< 0.001). There was no significant difference between the true value and measured value from 1.5-mm and 3-mm images. In the human study, 18 (30%) of 60 CAC lesions with an area < 20 mm2 defined on 3 mm images were not visible on 6-mm images. Sensitivity of small lesions (P< 5 mm2) was 48% using 6-mm slices. There was a smaller value in CAC area, mean and peak Hounsfield units and score measured from 6-mm images, as compared with 3 mm slices ( P< 0.05). Thinner slice imaging has a higher sensitivity to detect small calcium focus. There was no significant change in score between 3 mm and 1.5 mm on the cork phantom study. However, the use of 6-mm slices should be discouraged, as this protocol both underestimates calcific mass and misses a significant number of calcific lesions in both a phantom and human study.

  4. Monte Carlo calculation of the sensitivity of a commercial dose calibrator to gamma and beta radiation.

    PubMed

    Laedermann, Jean-Pascal; Valley, Jean-François; Bulling, Shelley; Bochud, François O

    2004-06-01

    The detection process used in a commercial dose calibrator was modeled using the GEANT 3 Monte Carlo code. Dose calibrator efficiency for gamma and beta emitters, and the response to monoenergetic photons and electrons was calculated. The model shows that beta emitters below 2.5 MeV deposit energy indirectly in the detector through bremsstrahlung produced in the chamber wall or in the source itself. Higher energy beta emitters (E > 2.5 MeV) deposit energy directly in the chamber sensitive volume, and dose calibrator sensitivity increases abruptly for these radionuclides. The Monte Carlo calculations were compared with gamma and beta emitter measurements. The calculations show that the variation in dose calibrator efficiency with measuring conditions (source volume, container diameter, container wall thickness and material, position of the source within the calibrator) is relatively small and can be considered insignificant for routine measurement applications. However, dose calibrator efficiency depends strongly on the inner-wall thickness of the detector.

  5. Time reversal optical tomography and decomposition methods for detection and localization of targets in highly scattering turbid media

    NASA Astrophysics Data System (ADS)

    Wu, Binlin

    New near-infrared (NIR) diffuse optical tomography (DOT) approaches were developed to detect, locate, and image small targets embedded in highly scattering turbid media. The first approach, referred to as time reversal optical tomography (TROT), is based on time reversal (TR) imaging and multiple signal classification (MUSIC). The second approach uses decomposition methods of non-negative matrix factorization (NMF) and principal component analysis (PCA) commonly used in blind source separation (BSS) problems, and compare the outcomes with that of optical imaging using independent component analysis (OPTICA). The goal is to develop a safe, affordable, noninvasive imaging modality for detection and characterization of breast tumors in early growth stages when those are more amenable to treatment. The efficacy of the approaches was tested using simulated data, and experiments involving model media and absorptive, scattering, and fluorescent targets, as well as, "realistic human breast model" composed of ex vivo breast tissues with embedded tumors. The experimental arrangements realized continuous wave (CW) multi-source probing of samples and multi-detector acquisition of diffusely transmitted signal in rectangular slab geometry. A data matrix was generated using the perturbation in the transmitted light intensity distribution due to the presence of absorptive or scattering targets. For fluorescent targets the data matrix was generated using the diffusely transmitted fluorescence signal distribution from the targets. The data matrix was analyzed using different approaches to detect and characterize the targets. The salient features of the approaches include ability to: (a) detect small targets; (b) provide three-dimensional location of the targets with high accuracy (~within a millimeter or 2); and (c) assess optical strength of the targets. The approaches are less computation intensive and consequently are faster than other inverse image reconstruction methods that attempt to reconstruct the optical properties of every voxel of the sample volume. The location of a target was estimated to be the weighted center of the optical property of the target. Consequently, the locations of small targets were better specified than those of the extended targets. It was more difficult to retrieve the size and shape of a target. The fluorescent measurements seemed to provide better accuracy than the transillumination measurements. In the case of ex vivo detection of tumors embedded in human breast tissue, measurements using multiple wavelengths provided more robust results, and helped suppress artifacts (false positives) than that from single wavelength measurements. The ability to detect and locate small targets, speedier reconstruction, combined with fluorophore-specific multi-wavelength probing has the potential to make these approaches suitable for breast cancer detection and diagnosis.

  6. Object strength--an accurate measure for small objects that is insensitive to partial volume effects.

    PubMed

    Tofts, P S; Silver, N C; Barker, G J; Gass, A

    2005-07-01

    There are currently four problems in characterising small nonuniform lesions or other objects in Magnetic Resonance images where partial volume effects are significant. Object size is over- or under-estimated; boundaries are often not reproducible; mean object value cannot be measured; and fuzzy borders cannot be accommodated. A new measure, Object Strength, is proposed. This is the sum of all abnormal intensities, above a uniform background value. For a uniform object, this is simply the product of the increase in intensity and the size of the object. Biologically, this could be at least as relevant as existing measures of size or mean intensity. We hypothesise that Object Strength will perform better than traditional area measurements in characterising small objects. In a pilot study, the reproducibility of object strength measurements was investigated using MR images of small multiple sclerosis (MS) lesions. In addition, accuracy was investigated using artificial lesions of known volume (0.3-6.2 ml) and realistic appearance. Reproducibility approached that of area measurements (in 33/90 lesion reports the difference between repeats was less than for area measurements). Total lesion volume was accurate to 0.2%. In conclusion, Object Strength has potential for improved characterisation of small lesions and objects in imaging and possibly spectroscopy.

  7. Crossed, Small-Deflection Energy Analyzer for Wind/Temperature Spectrometer

    NASA Technical Reports Server (NTRS)

    Herrero, Federico A.; Finne, Theodore T.

    2010-01-01

    Determination of neutral winds and ion drifts in low-Earth-orbit missions requires measurements of the angular and energy distributions of the flux of neutrals and ions entering the satellite from the ram direction. The magnitude and direction of the neutral-wind (or ion-drift) determine the location of the maximum in the angular distribution of the flux. Knowledge of the angle of maximum flux with respect to satellite coordinates (pointing) is essential to determine the wind (or ion-drift) vector. The crossed Small-Deflection Energy Analyzer (SDEA) spectrometer (see Figure 1) occupies minimal volume and consumes minimal power. Designed for upper atmosphere/ionosphere investigations at Earth altitudes above 100 km, the spectrometer operates by detecting the angular and energy distributions of neutral atoms/molecules and ions in two mutually perpendicular planes. In this configuration, the two detection planes actually cross at the spectrometer center. It is possible to merge two SDEAs so they share a common optical axis and alternate measurements between two perpendicular planes, and reduce the number of ion sources from two to one. This minimizes the volume and footprint significantly and reduces the ion source power by a factor of two. The area of the entrance aperture affects the number of ions detected/second and also determines the energy resolution. Thermionic emitters require heater power of about 100 mW to produce 1 mA of electron beam current. Typically, electron energy is about 100 eV and requires a 100-V supply for electron acceleration to supply an additional 100 mW of power. Thus, ion source power is at most 200 mW. If two ion sources were to be used, the ion source power would be, at most, 400 mW. Detector power, deflection voltage power, and microcontroller and other functions require less than 150 mW. A WTS (wind/ temperature spectrometer) with two separate optical axes would consume about 650 mW, while the crossed SDEA described here consumes about 350 mW. The entrance aperture has a diameter of 0.004 in. (0.10 mm) to provide the required energy resolution between 0.05 and 0.15. This design (see Figure 2) provides a WTS occupying a volume less than 40 cm(sup 3), on a footprint of diameter about 1.5 in. (38 mm). The Crossed SDEA offers many advantages in the measurements of neutral wind and ion drifts in the Earth's thermosphere. As such, it will be useful in future commercial satellites dedicated to monitoring the ionosphere with a view to improving the integrity and predictability of GPS operations.

  8. 40 CFR 1051.625 - What special provisions apply to unique snowmobile designs for small-volume manufacturers?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false What special provisions apply to unique snowmobile designs for small-volume manufacturers? 1051.625 Section 1051.625 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM RECREATIONAL ENGINES AND VEHICLES Compliance...

  9. SU-G-IeP4-11: Monitoring Tumor Growth in Subcutaneous Murine Tumor Model in Vivo: A Comparison Between MRI and Small Animal CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, B; He, W; Cvetkovic, D

    Purpose: The purpose of the study is to compare the volume measurement of subcutaneous tumors in mice with different imaging platforms, namely a GE MRI and a Sofie-Biosciences small animal CT scanner. Methods: A549 human lung carcinoma cells and FaDu human head and neck squamous cell carcinoma cells were implanted subcutaneously into flanks of nude mice. Three FaDu tumors and three A549 tumors were included in this study. The MRI scans were done with a GE Signa 1.5 Tesla MR scanner using a fast T2-weighted sequence (70mm FOV and 1.2mm slice thickness), while the CT scans were done with themore » CT scanner on a Sofie-Biosciences G8 PET/CT platform dedicated for small animal studies (48mm FOV and 0.2mm slice thickness). Imaging contrast agent was not used in this study. Based on the DICOM images from MRI and CT scans, the tumors were contoured with Philips DICOM Viewer and the tumor volumes were obtained by summing up the contoured area and multiplied by the slice thickness. Results: The volume measurements based on the CT scans agree reasonably with that obtained with MR images for the subcutaneous tumors. The mean difference in the absolute tumor volumes between MRI- and CT-based measurements was found to be −6.2% ± 1.0%, with the difference defined as (VMR – VCT)*100%/VMR. Furthermore, we evaluated the normalized tumor volumes, which were defined for each tumor as V/V{sub 0} where V{sub 0} stands for the volume from the first MR or CT scan. The mean difference in the normalized tumor volumes was found to be 0.10% ± 0.96%. Conclusion: Despite the fact that the difference between normal and abnormal tissues is often less clear on small animal CT images than on MR images, one can still obtain reasonable tumor volume information with the small animal CT scans for subcutaneous murine xenograft models.« less

  10. Evaluation of Small Mass Spectrometer Systems

    NASA Technical Reports Server (NTRS)

    Arkin, C. Richard; Griffin, Timothy P.; Ottens, Andrew K.; Diaz, Jorge A.; Follistein, Duke W.; Adams, Fredrick W.; Helms, William R.; Voska, N. (Technical Monitor)

    2002-01-01

    This work is aimed at understanding the aspects of designing a miniature mass spectrometer (MS) system. A multitude of commercial and government sectors, such as the military, environmental agencies and industrial manufacturers of semiconductors, refrigerants, and petroleum products, would find a small, portable, rugged and reliable MS system beneficial. Several types of small MS systems are evaluated and discussed, including linear quadrupole, quadrupole ion trap, time of flight and sector. The performance of each system in terms of accuracy, precision, limits of detection, response time, recovery time, scan rate, volume and weight is assessed. A performance scale is setup to rank each systems and an overall performance score is given to each system. All experiments involved the analysis of hydrogen, helium, oxygen and argon in a nitrogen background with the concentrations of the components of interest ranging from 0-5000 part-per-million (ppm). The relative accuracies of the systems vary from < 1% to approx. 40% with an average below 10%. Relative precisions varied from 1% to 20%, with an average below 5%. The detection limits had a large distribution, ranging from 0.2 to 170 ppm. The systems had a diverse response time ranging from 4 s to 210 s as did the recovery time with a 6 s to 210 s distribution. Most instruments had scan times near, 1 s, however one instrument exceeded 13 s. System weights varied from 9 to 52 kg and sizes from 15 x 10(exp 3)cu cm to 110 x 10(exp 3) cu cm.

  11. Novel Stool-Based Protein Biomarkers for Improved Colorectal Cancer Screening: A Case-Control Study.

    PubMed

    Bosch, Linda J W; de Wit, Meike; Pham, Thang V; Coupé, Veerle M H; Hiemstra, Annemieke C; Piersma, Sander R; Oudgenoeg, Gideon; Scheffer, George L; Mongera, Sandra; Sive Droste, Jochim Terhaar; Oort, Frank A; van Turenhout, Sietze T; Larbi, Ilhame Ben; Louwagie, Joost; van Criekinge, Wim; van der Hulst, Rene W M; Mulder, Chris J J; Carvalho, Beatriz; Fijneman, Remond J A; Jimenez, Connie R; Meijer, Gerrit A

    2017-12-19

    The fecal immunochemical test (FIT) for detecting hemoglobin is used widely for noninvasive colorectal cancer (CRC) screening, but its sensitivity leaves room for improvement. To identify novel protein biomarkers in stool that outperform or complement hemoglobin in detecting CRC and advanced adenomas. Case-control study. Colonoscopy-controlled referral population from several centers. 315 stool samples from one series of 12 patients with CRC and 10 persons without colorectal neoplasia (control samples) and a second series of 81 patients with CRC, 40 with advanced adenomas, and 43 with nonadvanced adenomas, as well as 129 persons without colorectal neoplasia (control samples); 72 FIT samples from a third independent series of 14 patients with CRC, 16 with advanced adenomas, and 18 with nonadvanced adenomas, as well as 24 persons without colorectal neoplasia (control samples). Stool samples were analyzed by mass spectrometry. Classification and regression tree (CART) analysis and logistic regression analyses were performed to identify protein combinations that differentiated CRC or advanced adenoma from control samples. Antibody-based assays for 4 selected proteins were done on FIT samples. In total, 834 human proteins were identified, 29 of which were statistically significantly enriched in CRC versus control stool samples in both series. Combinations of 4 proteins reached sensitivities of 80% and 45% for detecting CRC and advanced adenomas, respectively, at 95% specificity, which was higher than that of hemoglobin alone (P < 0.001 and P = 0.003, respectively). Selected proteins could be measured in small sample volumes used in FIT-based screening programs and discriminated between CRC and control samples (P < 0.001). Lack of availability of antibodies prohibited validation of the top protein combinations in FIT samples. Mass spectrometry of stool samples identified novel candidate protein biomarkers for CRC screening. Several protein combinations outperformed hemoglobin in discriminating CRC or advanced adenoma from control samples. Proof of concept that such proteins can be detected with antibody-based assays in small sample volumes indicates the potential of these biomarkers to be applied in population screening. Center for Translational Molecular Medicine, International Translational Cancer Research Dream Team, Stand Up to Cancer (American Association for Cancer Research and the Dutch Cancer Society), Dutch Digestive Foundation, and VU University Medical Center.

  12. An improved three-dimensional non-scanning laser imaging system based on digital micromirror device

    NASA Astrophysics Data System (ADS)

    Xia, Wenze; Han, Shaokun; Lei, Jieyu; Zhai, Yu; Timofeev, Alexander N.

    2018-01-01

    Nowadays, there are two main methods to realize three-dimensional non-scanning laser imaging detection, which are detection method based on APD and detection method based on Streak Tube. However, the detection method based on APD possesses some disadvantages, such as small number of pixels, big pixel interval and complex supporting circuit. The detection method based on Streak Tube possesses some disadvantages, such as big volume, bad reliability and high cost. In order to resolve the above questions, this paper proposes an improved three-dimensional non-scanning laser imaging system based on Digital Micromirror Device. In this imaging system, accurate control of laser beams and compact design of imaging structure are realized by several quarter-wave plates and a polarizing beam splitter. The remapping fiber optics is used to sample the image plane of receiving optical lens, and transform the image into line light resource, which can realize the non-scanning imaging principle. The Digital Micromirror Device is used to convert laser pulses from temporal domain to spatial domain. The CCD with strong sensitivity is used to detect the final reflected laser pulses. In this paper, we also use an algorithm which is used to simulate this improved laser imaging system. In the last, the simulated imaging experiment demonstrates that this improved laser imaging system can realize three-dimensional non-scanning laser imaging detection.

  13. Detection of triazole deicing additives in soil samples from airports with low, mid, and large volume aircraft deicing activities.

    PubMed

    McNeill, K S; Cancilla, D A

    2009-03-01

    Soil samples from three USA airports representing low, mid, and large volume users of aircraft deicing fluids (ADAFs) were analyzed by LC/MS/MS for the presence of triazoles, a class of corrosion inhibitors historically used in ADAFs. Triazoles, specifically the 4-methyl-1H-benzotriazole and the 5-methyl-1H-benzotriazole, were detected in a majority of samples and ranged from 2.35 to 424.19 microg/kg. Previous studies have focused primarily on ground and surface water impacts of larger volume ADAF users. The detection of triazoles in soils at low volume ADAF use airports suggests that deicing activities may have a broader environmental impact than previously considered.

  14. Evaluation of counting methods for oceanic radium-228

    NASA Astrophysics Data System (ADS)

    Orr, James C.

    1988-07-01

    Measurement of open ocean 228Ra is difficult, typically requiring at least 200 L of seawater. The burden of collecting and processing these large-volume samples severely limits the widespread use of this promising tracer. To use smaller-volume samples, a more sensitive means of analysis is required. To seek out new and improved counting method(s), conventional 228Ra counting methods have been compared with some promising techniques which are currently used for other radionuclides. Of the conventional methods, α spectrometry possesses the highest efficiency (3-9%) and lowest background (0.0015 cpm), but it suffers from the need for complex chemical processing after sampling and the need to allow about 1 year for adequate ingrowth of 228Th granddaughter. The other two conventional counting methods measure the short-lived 228Ac daughter while it remains supported by 228Ra, thereby avoiding the complex sample processing and the long delay before counting. The first of these, high-resolution γ spectrometry, offers the simplest processing and an efficiency (4.8%) comparable to α spectrometry; yet its high background (0.16 cpm) and substantial equipment cost (˜30,000) limit its widespread use. The second no-wait method, β-γ coincidence spectrometry, also offers comparable efficiency (5.3%), but it possesses both lower background (0.0054 cpm) and lower initial cost (˜12,000). Three new (i.e., untried for 228Ra) techniques all seem to promise about a fivefold increase in efficiency over conventional methods. By employing liquid scintillation methods, both α spectrometry and β-γ coincidence spectrometry can improve their counter efficiency while retaining low background. The third new 228Ra counting method could be adapted from a technique which measures 224Ra by 220Rn emanation. After allowing for ingrowth and then counting for the 224Ra great-granddaughter, 228Ra could be back calculated, thereby yielding a method with high efficiency, where no sample processing is required. The efficiency and background of each of the three new methods have been estimated and are compared with those of the three methods currently employed to measure oceanic 228Ra. From efficiency and background, the relative figure of merit and the detection limit have been determined for each of the six counters. These data suggest that the new counting methods have the potential to measure most 228Ra samples with just 30 L of seawater, to better than 5% precision. Not only would this reduce the time, effort, and expense involved in sample collection, but 228Ra could then be measured on many small-volume samples (20-30 L) previously collected with only 226Ra in mind. By measuring 228Ra quantitatively on such small-volume samples, three analyses (large-volume 228Ra, large-volume 226Ra, and small-volume 226Ra) could be reduced to one, thereby dramatically improving analytical precision.

  15. Detector to detector corrections: a comprehensive experimental study of detector specific correction factors for beam output measurements for small radiotherapy beams.

    PubMed

    Azangwe, Godfrey; Grochowska, Paulina; Georg, Dietmar; Izewska, Joanna; Hopfgartner, Johannes; Lechner, Wolfgang; Andersen, Claus E; Beierholm, Anders R; Helt-Hansen, Jakob; Mizuno, Hideyuki; Fukumura, Akifumi; Yajima, Kaori; Gouldstone, Clare; Sharpe, Peter; Meghzifene, Ahmed; Palmans, Hugo

    2014-07-01

    The aim of the present study is to provide a comprehensive set of detector specific correction factors for beam output measurements for small beams, for a wide range of real time and passive detectors. The detector specific correction factors determined in this study may be potentially useful as a reference data set for small beam dosimetry measurements. Dose response of passive and real time detectors was investigated for small field sizes shaped with a micromultileaf collimator ranging from 0.6 × 0.6 cm(2) to 4.2 × 4.2 cm(2) and the measurements were extended to larger fields of up to 10 × 10 cm(2). Measurements were performed at 5 cm depth, in a 6 MV photon beam. Detectors used included alanine, thermoluminescent dosimeters (TLDs), stereotactic diode, electron diode, photon diode, radiophotoluminescent dosimeters (RPLDs), radioluminescence detector based on carbon-doped aluminium oxide (Al2O3:C), organic plastic scintillators, diamond detectors, liquid filled ion chamber, and a range of small volume air filled ionization chambers (volumes ranging from 0.002 cm(3) to 0.3 cm(3)). All detector measurements were corrected for volume averaging effect and compared with dose ratios determined from alanine to derive a detector correction factors that account for beam perturbation related to nonwater equivalence of the detector materials. For the detectors used in this study, volume averaging corrections ranged from unity for the smallest detectors such as the diodes, 1.148 for the 0.14 cm(3) air filled ionization chamber and were as high as 1.924 for the 0.3 cm(3) ionization chamber. After applying volume averaging corrections, the detector readings were consistent among themselves and with alanine measurements for several small detectors but they differed for larger detectors, in particular for some small ionization chambers with volumes larger than 0.1 cm(3). The results demonstrate how important it is for the appropriate corrections to be applied to give consistent and accurate measurements for a range of detectors in small beam geometry. The results further demonstrate that depending on the choice of detectors, there is a potential for large errors when effects such as volume averaging, perturbation and differences in material properties of detectors are not taken into account. As the commissioning of small fields for clinical treatment has to rely on accurate dose measurements, the authors recommend the use of detectors that require relatively little correction, such as unshielded diodes, diamond detectors or microchambers, and solid state detectors such as alanine, TLD, Al2O3:C, or scintillators.

  16. Massive-training artificial neural network (MTANN) for reduction of false positives in computer-aided detection of polyps: Suppression of rectal tubes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suzuki, Kenji; Yoshida, Hiroyuki; Naeppi, Janne

    2006-10-15

    One of the limitations of the current computer-aided detection (CAD) of polyps in CT colonography (CTC) is a relatively large number of false-positive (FP) detections. Rectal tubes (RTs) are one of the typical sources of FPs because a portion of a RT, especially a portion of a bulbous tip, often exhibits a cap-like shape that closely mimics the appearance of a small polyp. Radiologists can easily recognize and dismiss RT-induced FPs; thus, they may lose their confidence in CAD as an effective tool if the CAD scheme generates such ''obvious'' FPs due to RTs consistently. In addition, RT-induced FPs maymore » distract radiologists from less common true positives in the rectum. Therefore, removal RT-induced FPs as well as other types of FPs is desirable while maintaining a high sensitivity in the detection of polyps. We developed a three-dimensional (3D) massive-training artificial neural network (MTANN) for distinction between polyps and RTs in 3D CTC volumetric data. The 3D MTANN is a supervised volume-processing technique which is trained with input CTC volumes and the corresponding ''teaching'' volumes. The teaching volume for a polyp contains a 3D Gaussian distribution, and that for a RT contains zeros for enhancement of polyps and suppression of RTs, respectively. For distinction between polyps and nonpolyps including RTs, a 3D scoring method based on a 3D Gaussian weighting function is applied to the output of the trained 3D MTANN. Our database consisted of CTC examinations of 73 patients, scanned in both supine and prone positions (146 CTC data sets in total), with optical colonoscopy as a reference standard for the presence of polyps. Fifteen patients had 28 polyps, 15 of which were 5-9 mm and 13 were 10-25 mm in size. These CTC cases were subjected to our previously reported CAD scheme that included centerline-based segmentation of the colon, shape-based detection of polyps, and reduction of FPs by use of a Bayesian neural network based on geometric and texture features. Application of this CAD scheme yielded 96.4% (27/28) by-polyp sensitivity with 3.1 (224/73) FPs per patient, among which 20 FPs were caused by RTs. To eliminate the FPs due to RTs and possibly other normal structures, we trained a 3D MTANN with ten representative polyps and ten RTs, and applied the trained 3D MTANN to the above CAD true- and false-positive detections. In the output volumes of the 3D MTANN, polyps were represented by distributions of bright voxels, whereas RTs and other normal structures partly similar to RTs appeared as darker voxels, indicating the ability of the 3D MTANN to suppress RTs as well as other normal structures effectively. Application of the 3D MTANN to the CAD detections showed that the 3D MTANN eliminated all RT-induced 20 FPs, as well as 53 FPs due to other causes, without removal of any true positives. Overall, the 3D MTANN was able to reduce the FP rate of the CAD scheme from 3.1 to 2.1 FPs per patient (33% reduction), while the original by-polyp sensitivity of 96.4% was maintained.« less

  17. Stochastic theory of large-scale enzyme-reaction networks: Finite copy number corrections to rate equation models

    NASA Astrophysics Data System (ADS)

    Thomas, Philipp; Straube, Arthur V.; Grima, Ramon

    2010-11-01

    Chemical reactions inside cells occur in compartment volumes in the range of atto- to femtoliters. Physiological concentrations realized in such small volumes imply low copy numbers of interacting molecules with the consequence of considerable fluctuations in the concentrations. In contrast, rate equation models are based on the implicit assumption of infinitely large numbers of interacting molecules, or equivalently, that reactions occur in infinite volumes at constant macroscopic concentrations. In this article we compute the finite-volume corrections (or equivalently the finite copy number corrections) to the solutions of the rate equations for chemical reaction networks composed of arbitrarily large numbers of enzyme-catalyzed reactions which are confined inside a small subcellular compartment. This is achieved by applying a mesoscopic version of the quasisteady-state assumption to the exact Fokker-Planck equation associated with the Poisson representation of the chemical master equation. The procedure yields impressively simple and compact expressions for the finite-volume corrections. We prove that the predictions of the rate equations will always underestimate the actual steady-state substrate concentrations for an enzyme-reaction network confined in a small volume. In particular we show that the finite-volume corrections increase with decreasing subcellular volume, decreasing Michaelis-Menten constants, and increasing enzyme saturation. The magnitude of the corrections depends sensitively on the topology of the network. The predictions of the theory are shown to be in excellent agreement with stochastic simulations for two types of networks typically associated with protein methylation and metabolism.

  18. Department of Defense Fiscal Year (FY) 2005 Budget Estimates. Research, Development, Test and Evaluation, Defense-Wide. Volume 1 - Defense Advanced Research Projects Agency

    DTIC Science & Technology

    2004-02-01

    UNCLASSIFIED − Conducted experiments to determine the usability of general-purpose anomaly detection algorithms to monitor a large, complex military...reaction and detection modules to perform tailored analysis sequences to monitor environmental conditions, health hazards and physiological states...scalability of lab proven anomaly detection techniques for intrusion detection in real world high volume environments. Narrative Title FY 2003

  19. 'Non-hypotensive' hypovolaemia reduces ascending aortic dimensions in humans

    NASA Technical Reports Server (NTRS)

    Taylor, J. A.; Halliwill, J. R.; Brown, T. E.; Hayano, J.; Eckberg, D. L.

    1995-01-01

    1. The notion that small, 'non-hypotensive' reductions of effective blood volume alter neither arterial pressure nor arterial baroreceptor activity is pervasive in the experimental literature. We tested two hypotheses: (a) that minute arterial pressure and cardiac autonomic outflow changes during hypovolaemia induced by lower body suction in humans are masked by alterations in breathing, and (b) that evidence for arterial baroreflex engagement might be obtained from measurements of thoracic aorta dimensions. 2. In two studies, responses to graded lower body suction at 0 (control), 5, 10, 15, 20 and 40 mmHg were examined in twelve and ten healthy young men, respectively. In the first, arterial pressure (photoplethysmograph), R-R interval, and respiratory sinus arrhythmia amplitude (complex demodulation) were measured during uncontrolled and controlled breathing (constant breathing frequency and tidal volume). In the second, cross-sectional areas of the ascending thoracic aorta were calculated from nuclear magnetic resonance images. 3. Lower body suction with controlled breathing resulted in an increased arterial pulse pressure at mild levels (5-20 mmHg; ANOVA, P < 0.05) and a decreased arterial pulse pressure at moderate levels (40 mmHg; ANOVA, P < 0.05). Both R-R intervals and respiratory sinus arrhythmia were negatively related to lower body suction level, whether group averages (general linear regression, r > 0.92) or individual subjects (orthogonal polynomials, 12 of 12 subjects) were assessed. 4. Aortic pulse area decreased progressively and significantly during mild lower body suction, with 47% of the total decline occurring by 5 mmHg. 5. These results suggest that small reductions of effective blood volume reduce aortic baroreceptive areas and trigger haemodynamic adjustments which are so efficient that alterations in arterial pressure escape detection by conventional means.

  20. A contactless ultrasonic surface wave approach to characterize distributed cracking damage in concrete.

    PubMed

    Ham, Suyun; Song, Homin; Oelze, Michael L; Popovics, John S

    2017-03-01

    We describe an approach that utilizes ultrasonic surface wave backscatter measurements to characterize the volume content of relatively small distributed defects (microcrack networks) in concrete. A simplified weak scattering model is used to demonstrate that the scattered wave field projected in the direction of the surface wave propagation is relatively insensitive to scatterers that are smaller than the propagating wavelength, while the scattered field projected in the opposite direction is more sensitive to sub-wavelength scatterers. Distributed microcracks in the concrete serve as the small scatterers that interact with a propagating surface wave. Data from a finite element simulation were used to demonstrate the viability of the proposed approach, and also to optimize a testing configuration to collect data. Simulations were validated through experimental measurements of ultrasonic backscattered surface waves from test samples of concrete constructed with different concentrations of fiber filler (0.0, 0.3 and 0.6%) to mimic increasing microcrack volume density and then samples with actual cracking induced by controlled thermal cycles. A surface wave was induced in the concrete samples by a 50kHz ultrasonic source operating 10mm above the surface at an angle of incidence of 9°. Silicon-based miniature MEMS acoustic sensors located a few millimeters above the concrete surface both behind and in front of the sender were used to detect leaky ultrasonic surface waves emanating from concrete. A normalized backscattered energy parameter was calculated from the signals. Statistically significant differences in the normalized backscattered energy were observed between concrete samples with varying levels of simulated and actual cracking damage volume. Copyright © 2016 Elsevier B.V. All rights reserved.

Top