Sample records for small light weight

  1. Joint Small Arms Technology Development Strategy for Joint Service Small Arms Science and Technology Investments

    DTIC Science & Technology

    2016-01-26

    Scope/Objectives Reiterating, this discussion is limited to small arms; those of .50 caliber and smaller plus low velocity and high 40mm...ballistic trajectory are included, plus abilities to engage targets in defilade such as by fragmentation effects for enemy located behind retaining walls...Electromagnetic Pulse (EMP) Weapons 3 2 Light Weight Small Arms / Light Weight Materials 2 2 Munition Guidance 2 2 Pain Beams 2 2 Barrel Coatings 1 1

  2. Defense Small Business Innovation Research Program (SBIR) FY 1983.

    DTIC Science & Technology

    1983-05-31

    matching networks for application in the frequency band below 30 MHz. The antenna should be light - weight, rapidly erectable and capable of operation while...munitions concealed within this terrain. m. More Efficient Utilization of Fuel in Light Trucks and Off-Road Vehi- cles (11) Current research is focusing on...affixed. The material must be light - * weight, small, and inexpensive to buy and install. d. Hard Coatings for Optical Systems (7) Broadband sensors

  3. A small and light weight heat exchanger for on-board helium refrigerator

    NASA Technical Reports Server (NTRS)

    Koizumi, T.; Takahashi, M.; Uchida, T.; Kanazawa, Y.; Suzuki, M.

    1983-01-01

    A small and light weight heat exchanger used for small helium refrigerator has been developed by Sumitomo Heavy Industries, Ltd. This heat exchanger is a laminated metal heat exchanger which consists of perforated aluminum metal plates and glassfiber reinforced plastic separators. The size is from 100 mm to 28 mm in diameter and about 300 mm in length. The weight is from 2.5 kg to 0.6 kg. Also it can be used between room temperature and liquid helium temperature. The thermal efficiency obtained has been more than 96%. The heat exchanger has been practically used for on-board helium refrigerator in Japanese National Railways' superconducting magnetic levitated trains.

  4. Design and fabrication of light weight current collectors for direct methanol fuel cells using the micro-electro mechanical system technique

    NASA Astrophysics Data System (ADS)

    Sung, Min-Feng; Kuan, Yean-Der; Chen, Bing-Xian; Lee, Shi-Min

    The direct methanol fuel cell (DMFC) is suitable for portable applications. Therefore, a light weight and small size is desirable. The main objective of this paper is to design and fabricate a light weight current collector for DMFC usage. The light weight current collector mainly consists of a substrate with two thin film metal layers. The substrate of the current collector is an FR4 epoxy plate. The thin film metal layers are accomplished by the thermo coater technique to coat metal powders onto the substrate surfaces. The developed light weight current collectors are further assembled to a single cell DMFC test fixture to measure the cell performance. The results show that the proposed current collectors could even be applied to DMFCs because they are light, thin and low cost and have potential for mass production.

  5. Design of light-small high-speed image data processing system

    NASA Astrophysics Data System (ADS)

    Yang, Jinbao; Feng, Xue; Li, Fei

    2015-10-01

    A light-small high speed image data processing system was designed in order to meet the request of image data processing in aerospace. System was constructed of FPGA, DSP and MCU (Micro-controller), implementing a video compress of 3 million pixels@15frames and real-time return of compressed image to the upper system. Programmable characteristic of FPGA, high performance image compress IC and configurable MCU were made best use to improve integration. Besides, hard-soft board design was introduced and PCB layout was optimized. At last, system achieved miniaturization, light-weight and fast heat dispersion. Experiments show that, system's multifunction was designed correctly and worked stably. In conclusion, system can be widely used in the area of light-small imaging.

  6. Light-assisted drying (LAD) of small volume biologics: a comparison of two IR light sources

    NASA Astrophysics Data System (ADS)

    Young, Madison A.; Van Vorst, Matthew; Elliott, Gloria D.; Trammell, Susan R.

    2016-03-01

    Protein therapeutics have been developed to treat diseases ranging from arthritis and psoriasis to cancer. A challenge in the development of protein-based drugs is maintaining the protein in the folded state during processing and storage. We are developing a novel processing method, light-assisted drying (LAD), to dehydrate proteins suspended in a sugar (trehalose) solution for storage at supra-zero temperatures. Our technique selectively heats the water in small volume samples using near-IR light to speed dehydration which prevents sugar crystallization that can damage embedded proteins. In this study, we compare the end moisture content (EMC) as a function of processing time of samples dried with two different light sources, Nd:YAG (1064 nm) and Thulium fiber (1850 nm) lasers. EMC is the ratio of water to dry weight in a sample and the lower the EMC the higher the possible storage temperature. LAD with the 1064 and 1850 nm lasers yielded 78% and 65% lower EMC, respectively, than standard air-drying. After 40 minutes of LAD with 1064 and 1850 nm sources, EMCs of 0.27+/-.27 and 0.15+/-.05 gH2O/gDryWeight were reached, which are near the desired value of 0.10 gH2O/gDryWeight that enables storage in a glassy state without refrigeration. LAD is a promising new technique for the preparation of biologics for anhydrous preservation.

  7. A small, sensitive, light-weight, and disposable aerosol spectrometer for balloon and UAV applications

    NASA Astrophysics Data System (ADS)

    Fahey, D. W.; Gao, R.; Thornberry, T. D.; Rollins, D. W.; Schwarz, J. P.; Perring, A. E.

    2013-12-01

    In-situ sampling with particle size spectrometers is an important method to provide detailed size spectra for atmospheric aerosol in the troposphere and stratosphere. The spectra are essential for understanding aerosol sources and aerosol chemical evolution and removal, and for aerosol remote sensing validation. These spectrometers are usually bulky, heavy, and expensive, thereby limiting their application to specific airborne platforms. Here we report a new type of small and light-weight optical aerosol particle size spectrometer that is sensitive enough for many aerosol applications yet is inexpensive enough to be disposable. 3D printing is used for producing structural components for simplicity and low cost. Weighing less than 1 kg individually, we expect these spectrometers can be deployed successfully on small unmanned aircraft systems (UASs) and up to 25 km on weather balloons. Immediate applications include the study of Arctic haze using the Manta UAS, detection of the Asian Tropopause Aerosol Layer in the Asian monsoon system and SAGE III validation onboard weather balloons.

  8. PULSE COUNTER

    DOEpatents

    Trumbo, D.E.

    1959-02-10

    A transistorized pulse-counting circuit adapted for use with nuclear radiation detecting detecting devices to provide a small, light weight portable counter is reported. The small size and low power requirements of the transistor are of particular value in this instance. The circuit provides an adjustable count scale with a single transistor which is triggered by the accumulated charge on a storage capacitor.

  9. Strain Modal Analysis of Small and Light Pipes Using Distributed Fibre Bragg Grating Sensors

    PubMed Central

    Huang, Jun; Zhou, Zude; Zhang, Lin; Chen, Juntao; Ji, Chunqian; Pham, Duc Truong

    2016-01-01

    Vibration fatigue failure is a critical problem of hydraulic pipes under severe working conditions. Strain modal testing of small and light pipes is a good option for dynamic characteristic evaluation, structural health monitoring and damage identification. Unique features such as small size, light weight, and high multiplexing capability enable Fibre Bragg Grating (FBG) sensors to measure structural dynamic responses where sensor size and placement are critical. In this paper, experimental strain modal analysis of pipes using distributed FBG sensors ispresented. Strain modal analysis and parameter identification methods are introduced. Experimental strain modal testing and finite element analysis for a cantilever pipe have been carried out. The analysis results indicate that the natural frequencies and strain mode shapes of the tested pipe acquired by FBG sensors are in good agreement with the results obtained by a reference accelerometer and simulation outputs. The strain modal parameters of a hydraulic pipe were obtained by the proposed strain modal testing method. FBG sensors have been shown to be useful in the experimental strain modal analysis of small and light pipes in mechanical, aeronautic and aerospace applications. PMID:27681728

  10. LED and Semiconductor Photo-effects on Living Things

    NASA Astrophysics Data System (ADS)

    Fujiyasu, Hiroshi; Ishigaki, Takemitsu; Fujiyasu, Kentarou; Ujihara, Shirou; Watanabe, Naoharu; Sunayama, Shunji; Ikoma, Shuuji

    We have studied LED irradiation effects on plants and animals in the visible to UV region of light from GaN LEDs. The results are as follows. Blue light considers to be effective for pearl cultivation or for attraction of small fishes living in near the surface of sea such as Pompano or Sardine, white light radiation is effective for cultivation of botanical plankton for shells. Other experiments of UV light irradiation attracting effect on baby sea turtle and the germination UV effect of mushroom, green light weight enhance effect on baby pigs, light vernalization effect of vegitable and Ge far infrared therapic effect on human body are also given.

  11. Weight and volume yields from thinning two oak-hickory stands

    Treesearch

    E. Paul Craft; John E. Baumgras

    1979-01-01

    Two sample plots in oak-hickory stands of poletimber-small sawtimber were thinned to determine product yields from thinnings. One stand received a light thinning; the other was heavily thinned. Light thinning reduced basal area from 120 ft² to 84 ft² per acre and removed 22 tons of roundwopd per acre, including 2,543 board feet of sawed products and 7...

  12. Gain weight by "going diet?" Artificial sweeteners and the neurobiology of sugar cravings: Neuroscience 2010.

    PubMed

    Yang, Qing

    2010-06-01

    America's obesity epidemic has gathered much media attention recently. A rise in the percent of the population who are obese coincides with an increase in the widespread use of non-caloric artificial sweeteners, such as aspartame (e.g., Diet Coke) and sucralose (e.g., Pepsi One), in food products (Figure 1). Both forward and reverse causalities have been proposed. While people often choose "diet" or "light" products to lose weight, research studies suggest that artificial sweeteners may contribute to weight gain. In this mini-review, inspired by a discussion with Dr. Dana Small at Yale's Neuroscience 2010 conference in April, I first examine the development of artificial sweeteners in a historic context. I then summarize the epidemiological and experimental evidence concerning their effects on weight. Finally, I attempt to explain those effects in light of the neurobiology of food reward.

  13. Runtime Performance Monitoring Tool for RTEMS System Software

    NASA Astrophysics Data System (ADS)

    Cho, B.; Kim, S.; Park, H.; Kim, H.; Choi, J.; Chae, D.; Lee, J.

    2007-08-01

    RTEMS is a commercial-grade real-time operating system that supports multi-processor computers. However, there are not many development tools for RTEMS. In this paper, we report new RTEMS-based runtime performance monitoring tool. We have implemented a light weight runtime monitoring task with an extension to the RTEMS APIs. Using our tool, software developers can verify various performance- related parameters during runtime. Our tool can be used during software development phase and in-orbit operation as well. Our implemented target agent is light weight and has small overhead using SpaceWire interface. Efforts to reduce overhead and to add other monitoring parameters are currently under research.

  14. Super Ball Bot - Structures for Planetary Landing and Exploration, NIAC Phase 2 Final Report

    NASA Technical Reports Server (NTRS)

    SunSpiral, Vytas; Agogino, Adrian; Atkinson, David

    2015-01-01

    Small, light-weight and low-cost missions will become increasingly important to NASA's exploration goals. Ideally teams of small, collapsible, light weight robots, will be conveniently packed during launch and would reliably separate and unpack at their destination. Such robots will allow rapid, reliable in-situ exploration of hazardous destination such as Titan, where imprecise terrain knowledge and unstable precipitation cycles make single-robot exploration problematic. Unfortunately landing lightweight conventional robots is difficult with current technology. Current robot designs are delicate, requiring a complex combination of devices such as parachutes, retrorockets and impact balloons to minimize impact forces and to place a robot in a proper orientation. Instead we are developing a radically different robot based on a "tensegrity" structure and built purely with tensile and compression elements. Such robots can be both a landing and a mobility platform allowing for dramatically simpler mission profile and reduced costs. These multi-purpose robots can be light-weight, compactly stored and deployed, absorb strong impacts, are redundant against single-point failures, can recover from different landing orientations and can provide surface mobility. These properties allow for unique mission profiles that can be carried out with low cost and high reliability and which minimizes the inefficient dependance on "use once and discard" mass associated with traditional landing systems. We believe tensegrity robot technology can play a critical role in future planetary exploration.

  15. Ultrathin metallized PBI paper

    NASA Technical Reports Server (NTRS)

    Chenevey, E. C.

    1978-01-01

    A study to determine the feasibility of preparing ultrathin papers with a target weight of 3.5 g/m squared from polybenzimidazole (PBI) fibrids was undertaken. Small hand sheets of target weight were fabricated. They were light brown, low density materials with sufficient strength to be readily handleable. Characterization of these sheets included strength, fold endurance, thermal gravimetric analysis in air and nitrogen and photomicrographs. Two different batches of PBI fibrids were studied and differences in fabrication performance were noted. In neither case could target weight papers be prepared using conventional paper making techniques.

  16. Metrology and Alignment of Light Weight Grazing Incidence X-Ray Mirrors

    NASA Technical Reports Server (NTRS)

    Zhang, William; Content, David; Petre, Robert; Saha, Timo

    2000-01-01

    Metrology and alignment of light weight X-ray optics have been a challenge for two reasons: (1) that the intrinsic mirror quality and distortions caused by handling can not be easily separated, and (2) the diffraction limits of the visible light become a severe problem at the order of one arc-minute. Traditional methods of using a normal incident pencil or small parallel beam which monitors a tiny fraction of the mirror in question at a given time can not adequately monitor those distortions. We are developing a normal incidence setup that monitors a large fraction, if not the whole, of the mirror at any given time. It will allow us to align thin X-ray mirrors to-an accuracy of a few arc seconds or to a limit dominated by the mirror intrinsic quality.

  17. Diffusion of Small Sticky Nanoparticles in a Polymer Melt: A Dynamic Light Scattering Study

    NASA Astrophysics Data System (ADS)

    Carroll, Bobby; Bocharova, Vera; Cheng, Shiwang; Yamamoto, Umi; Kisliuk, Alex; Schweizer, Ken; Sokolov, Alexei

    The study of dynamics in complex fluids such as polymers has gained a broad interest in advanced materials and biomedical applications. Of particular interest is the motion of nanoparticles in these systems, which influences the mechanical and structural properties of composite materials, properties of colloidal systems, and biochemical processes in biological systems. Theoretical work predicts a violation of Stokes-Einstein (SE) relationship for diffusion of small nanoparticles in strongly-entangled polymer melt systems, with diffusion of nanoparticles much faster than expected DSE. It is attributed to differences between local and macroscopic viscosity. In this study, the diffusion of nanoparticles in polymer melts below and above entanglement molecular weight is measured using dynamic light scattering. The measured results are compared with simulations that provide quantitative predictions for SE violations. Our results are two-fold: (1) diffusion at lower molecular weights is slower than expected DSE due to chain absorption; and (2) diffusion becomes much (20 times) faster than DSE, at higher entanglements due to a reduced local viscosity.

  18. Concepts for the development of light-weight composite structures for rotor burst containment

    NASA Technical Reports Server (NTRS)

    Holms, A. G.

    1977-01-01

    Based on published results on rotor burst containment with single materials, and on body armor using composite materials, a set of hypotheses is established as to what variables might control the design of a weight-efficient protective device. Based on modern concepts for the design and analysis of small optimum seeking experiments, a particular experiment for evaluating the hypotheses and materials was designed. The design and methods for the analysis of results are described.

  19. Spectrum-Modulating Fiber-Optic Sensors

    NASA Technical Reports Server (NTRS)

    Beheim, Glenn; Fritsch, Klaus

    1989-01-01

    Family of spectrum-modulating fiber-optic sensors undergoing development for use in aircraft-engine control systems. Fiber-optic sensors offer advantages of small size, high bandwidth, immunity to electromagnetic interference, and light weight. Furthermore, they reduce number of locations on aircraft to which electrical power has to be supplied.

  20. Tabletop computed lighting for practical digital photography.

    PubMed

    Mohan, Ankit; Bailey, Reynold; Waite, Jonathan; Tumblin, Jack; Grimm, Cindy; Bodenheimer, Bobby

    2007-01-01

    We apply simplified image-based lighting methods to reduce the equipment, cost, time, and specialized skills required for high-quality photographic lighting of desktop-sized static objects such as museum artifacts. We place the object and a computer-steered moving-head spotlight inside a simple foam-core enclosure and use a camera to record photos as the light scans the box interior. Optimization, guided by interactive user sketching, selects a small set of these photos whose weighted sum best matches the user-defined target sketch. Unlike previous image-based relighting efforts, our method requires only a single area light source, yet it can achieve high-resolution light positioning to avoid multiple sharp shadows. A reduced version uses only a handheld light and may be suitable for battery-powered field photography equipment that fits into a backpack.

  1. Study of small turbofan engines applicable to single-engine light airplanes

    NASA Technical Reports Server (NTRS)

    Merrill, G. L.

    1976-01-01

    The design, efficiency and cost factors are investigated for application of turbofan propulsion engines to single engine, general aviation light airplanes. A companion study of a hypothetical engine family of a thrust range suitable to such aircraft and having a high degree of commonality of design features and parts is presented. Future turbofan powered light airplanes can have a lower fuel consumption, lower weight, reduced airframe maintenance requirements and improved engine overhaul periods as compared to current piston engined powered airplanes. Achievement of compliance with noise and chemical emission regulations is expected without impairing performance, operating cost or safety.

  2. Scuba Weights

    NASA Technical Reports Server (NTRS)

    1995-01-01

    The Attitude Adjuster is a system for weight repositioning corresponding to a SCUBA diver's changing positions. Compact tubes on the diver's air tank permit controlled movement of lead balls within the Adjuster, automatically repositioning when the diver changes position. Manufactured by Think Tank Technologies, the system is light and small, reducing drag and energy requirements and contributing to lower air consumption. The Mid-Continent Technology Transfer Center helped the company with both technical and business information and arranged for the testing at Marshall Space Flight Center's Weightlessness Environmental Training Facility for astronauts.

  3. Can flexibility help you float?

    NASA Astrophysics Data System (ADS)

    Burton, L. J.; Bush, J. W. M.

    2012-10-01

    We consider the role of flexibility in the weight-bearing characteristics of bodies floating at an interface. Specifically, we develop a theoretical model for a two-dimensional thin floating plate that yields the maximum stable plate load and optimal stiffness for weight support. Plates small relative to the capillary length are primarily supported by surface tension, and their weight-bearing potential does not benefit from flexibility. Above a critical size comparable to the capillary length, flexibility assists interfacial flotation. For plates on the order of and larger than the capillary length, deflection from an initially flat shape increases the force resulting from hydrostatic pressure, allowing the plate to support a greater load. In this large plate limit, the shape that bears the most weight is a semicircle, which displaces the most fluid above the plate for a fixed plate length. Exact results for maximum weight-bearing plate shapes are compared to analytic approximations made in the limits of large and small plate sizes. The value of flexibility for floating to a number of biological organisms is discussed in light of our study.

  4. An Arbitrary Waveform Wearable Neuro-stimulator System for Neurophysiology Research on Freely Behaving Animals.

    PubMed

    Samani, Mohsen Mosayebi; Mahnam, Amin; Hosseini, Nasrin

    2014-04-01

    Portable wireless neuro-stimulators have been developed to facilitate long-term cognitive and behavioral studies on the central nervous system in freely moving animals. These stimulators can provide precisely controllable input(s) to the nervous system, without distracting the animal attention with cables connected to its body. In this study, a low power backpack neuro-stimulator was developed for animal brain researches that can provides arbitrary stimulus waveforms for the stimulation, while it is small and light weight to be used for small animals including rats. The system consists of a controller that uses an RF link to program and activate a small and light microprocessor-based stimulator. A Howland current source was implemented to produce precise current controlled arbitrary waveform stimulations. The system was optimized for ultra-low power consumption and small size. The stimulator was first tested for its electrical specifications. Then its performance was evaluated in a rat experiment when electrical stimulation of medial longitudinal fasciculus induced circling behavior. The stimulator is capable of delivering programmed stimulations up to ± 2 mA with adjusting steps of 1 μA, accuracy of 0.7% and compliance of 6 V. The stimulator is 15 mm × 20 mm × 40 mm in size, weights 13.5 g without battery and consumes a total power of only 5.l mW. In the experiment, the rat could easily carry the stimulator and demonstrated the circling behavior for 0.1 ms current pulses of above 400 μA. The developed system has a competitive size and weight, whereas providing a wide range of operation and the flexibility of generating arbitrary stimulation patterns ideal for long-term experiments in the field of cognitive and neuroscience research.

  5. A new perspective on the raindrop size distribution and its implications for retrievals of light rainfall

    NASA Astrophysics Data System (ADS)

    Gatlin, P. N.; Thurai, M.; Petersen, W. A.; Bringi, V. N.

    2017-12-01

    As GPM facilitates precipitation estimation at higher latitudes where light rainfall is more common it becomes more important that we can fully describe the raindrop size distribution (RSD) across the continuum of observed raindrop sizes. An adequate understanding and the capability to represent the RSD in light rain and drizzle extends from GPM radar algorithms into radiometer-based algorithms, where auto-conversion from cloud to rainwater contents and size distributions becomes important for light rain/drizzle estimation. This study provides insights into the effect of small raindrops on our ability to accurately map rainfall. The RSD has been widely defined using a gamma distribution—the assumption often being verified and approach being reinforced using measurements that imperfectly measure the small end of the RSD. However, we find that the gamma model as it is applied in its current form, to include commonly used disdrometer measurements to define it, is not capable of accurately describing the small raindrops we have observed during light rainfall. We demonstrate the difficulty encountered at light rain rates (e.g., 0.5 mm/hr or less) and for drops typically < 0.6 - 0.7 mm in diameter using a disdrometer with a pixel resolution of 50 microns operated alongside a 2DVD, with both instruments inside a small DFIR wind fence. Measurements were made in two locations with different climates—Greely, Colorado and Huntsville, Alabama. The resultant comparison reveals that the gamma RSD model overestimates the characteristic raindrop diameter (Dm), especially for light rainfall. A generalized gamma distribution provides a closer fit to the RSD observations across the continuum of raindrop sizes and highlights a drizzle mode of the RSD exists that would otherwise not be described with the commonly used gamma RSD model. Our analysis also suggests that RSD-based separation of stratiform and convective rainfall requires special consideration for light rainfall cases, especially those with small mass-weighted mean diameters (Dm < 0.6 mm).

  6. Solar flare and pulsar detection with small balloon borne scintillator detector

    NASA Astrophysics Data System (ADS)

    Sarkar, Ritabrata; Chakrabarti, Sandip Kumar; Bhowmick, Debashis; Bhattacharya, Arnab

    2016-07-01

    We present radiation measurement data from the Sun and the Crab Pulsar using a very light weight payload comprising a scintillator detector from one of the ongoing missions carried out by Indian Centre for Space Physics, India. This is a unique observation in the sense that the payload containing the detector unit was carried off above the Earth atmosphere using small weather balloons in a very cost effective way and with severe weight constraints. In this Mission we have been able to observe two consecutive solar flares and radiation from the Crab pulsar when the payload was under 30 km altitude. We present a brief description of the mission strategy and the temporal and spectral analysis of the data from those sources.

  7. Scaling laws for light weight optics, studies of light weight mirrors mounting and dynamic mirror stress, and light weight mirror and mount designs

    NASA Technical Reports Server (NTRS)

    Vukobratovich, Daniel; Richard, Ralph M.; Valente, Tina M.; Cho, Myung K.

    1990-01-01

    Scaling laws for light-weight optical systems are examined. A cubic relationship between mirror diameter and weight has been suggested and used by many designers of optical systems as the best description for all light-weight mirrors. A survey of existing light-weight systems in the open literature was made to clarify this issue. Fifty existing optical systems were surveyed with all varieties of light-weight mirrors including glass and beryllium structured mirrors, contoured mirrors, and very thin solid mirrors. These mirrors were then categorized and weight to diameter ratio was plotted to find a best curve for each case. A best fitting curve program tests nineteen different equations and ranks a goodness-to-fit for each of these equations. The resulting relationship found for each light-weight mirror category helps to quantify light-weight optical systems and methods of fabrication and provides comparisons between mirror types.

  8. Photoperiod shift effects on yield characteristics of rice

    NASA Technical Reports Server (NTRS)

    Volk, G. M.; Mitchell, C. A.

    1995-01-01

    Edible yield must be maximized for each crop species selected for inclusion in the Controlled Ecological Life-Support System (CELSS) proposed by NASA to support long-term manned space missions. In a greenhouse study aimed at increasing biomass partitioning to rice (Oryza sativa L.) grain, plants of the high yielding semi-dwarf rice cultivar Ai-Nan-Tsao were started in pots under 8-h photoperiods at a density of 212 plants m-2. After different periods of time under 8-h photoperiods, pots were switched to continuous light for the remainder of the cropping cycle. Continuous light did not delay time to first panicle emergence (60 d) or time to harvest (83 d). There was a positive correlation between the length of continuous light treatments and nongrain biomass. Grain yield (1.6 +/- 0.2 g plant-1) did not increase in continuous light. Yield-efficiency rate (grain weight per length of cropping cycle, canopy volume, and weight of nongrain shoot biomass) was used to compare treatments. Small Ai-Nan-Tsao rice canopies grown under 8-h photoperiods were more efficient producers of grain than canopies grown under continuous light for a portion of the rice cropping cycle.

  9. Study of small turbofan engines applicable to single-engine light airplanes. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Merrill, G.L.

    1976-09-01

    The design, efficiency and cost factors are investigated for application of turbofan propulsion engines to single engine, general aviation light airplanes. A companion study of a hypothetical engine family of a thrust range suitable to such aircraft and having a high degree of commonality of design features and parts is presented. Future turbofan powered light airplanes can have a lower fuel consumption, lower weight, reduced airframe maintenance requirements and improved engine overhaul periods as compared to current piston engined powered airplanes. Achievement of compliance with noise and chemical emission regulations is expected without impairing performance, operating cost or safety.

  10. Local Positioning System Using Flickering Infrared LEDs

    PubMed Central

    Raharijaona, Thibaut; Mawonou, Rodolphe; Nguyen, Thanh Vu; Colonnier, Fabien; Boyron, Marc; Diperi, Julien; Viollet, Stéphane

    2017-01-01

    A minimalistic optical sensing device for the indoor localization is proposed to estimate the relative position between the sensor and active markers using amplitude modulated infrared light. The innovative insect-based sensor can measure azimuth and elevation angles with respect to two small and cheap active infrared light emitting diodes (LEDs) flickering at two different frequencies. In comparison to a previous lensless visual sensor that we proposed for proximal localization (less than 30 cm), we implemented: (i) a minimalistic sensor in terms of small size (10 cm3), light weight (6 g) and low power consumption (0.4 W); (ii) an Arduino-compatible demodulator for fast analog signal processing requiring low computational resources; and (iii) an indoor positioning system for a mobile robotic application. Our results confirmed that the proposed sensor was able to estimate the position at a distance of 2 m with an accuracy as small as 2-cm at a sampling frequency of 100 Hz. Our sensor can be also suitable to be implemented in a position feedback loop for indoor robotic applications in GPS-denied environment. PMID:29099743

  11. Carbon Fiber Mirror for a CubeSat Telescope

    NASA Astrophysics Data System (ADS)

    Kim, Young-Soo; Jang, Jeong Gyun; Kim, Jihun; Nam, Uk Won

    2017-08-01

    Telescope mirrors made by carbon fibers have been increasingly used especially for space applications, and they may replace the traditional glass mirrors. Glass mirrors are easy to fabricate, but needed to be carefully handled as they are brittle. Other materials have also been considered for telescope mirrors, such as metals, plastics, and liquids even. However glass and glass ceramics are still commonly and dominantly used.Carbon fiber has mainly been used for mechanical supports like truss structure and telescope tubes, as it is stiff and light-weight. It can also be a good material for telescope mirrors, as it has additional merits of non-brittle and very low thermal expansion. Therefore, carbon fiber mirror would be suitable for space telescopes which should endure the harsh vibration conditions during launch.A light-weight telescope made by carbon fiber has been designed for a small satellite which would have much less weight than conventional ones. In this poster, mirror materials are reviewed, and a design of carbon fiber telescope is presented and discussed.

  12. Silicon-Etalon Fiber-Optic Temperature Sensor

    NASA Technical Reports Server (NTRS)

    Beheim, Glenn; Fritsch, Klaus; Flatico, Joseph M.; Azar, Massood Tabib

    1993-01-01

    Developmental temperature sensor consists of silicon Fabry-Perot etalon attached to end of optical fiber. Features immunity to electrical interference, small size, light weight, safety, and chemical inertness. Output encoded in ration of intensities at two different wavelengths, rather than in overall intensity, with result that temperature readings not degraded much by changes in transmittance of fiber-optic link.

  13. Direct-current converter for gas-discharge lamps

    NASA Technical Reports Server (NTRS)

    Lutus, P.

    1980-01-01

    Metal/halide and similar gas-discharge lamps are powered from low-voltage dc source using small efficient converter. Converter is useful whenever 60-cycle ac power is not available or where space and weight allocations are limited. Possible applications are offshore platforms, mobile homes, and emergency lighting. Design innovations give supply high reliability and efficiency up to 75 percent.

  14. Development and investigation of single-scan TV radiography for the acquisition of dynamic physiologic data

    NASA Technical Reports Server (NTRS)

    Baily, N. A.

    1975-01-01

    A light amplifier for large flat screen fluoroscopy was investigated which will decrease both its size and weight. The work on organ contouring was extended to yield volumes. This is a simple extension since the fluoroscopic image contains density (gray scale) information which can be translated as tissue thickness, integrated, yielding accurate volume data in an on-line situation. A number of devices were developed for analog image processing of video signals, operating on-line in real time, and with simple selection mechanisms. The results show that this approach is feasible and produces are improvement in image quality which should make diagnostic error significantly lower. These are all low cost devices, small and light in weight, thereby making them usable in a space environment, on the Ames centrifuge, and in a typical clinical situation.

  15. Scaling laws for light-weight optics

    NASA Technical Reports Server (NTRS)

    Valente, Tina M.

    1990-01-01

    Scaling laws for light-weight optical systems are examined. A cubic relationship between mirror diameter and weight has been suggested and used by many designers of optical systems as the best description for all light-weight mirrors. A survey of existing light-weight systems in the open literature has been made to clarify this issue. Fifty existing optical systems were surveyed with all varieties of light-weight mirrors including glass and beryllium structured mirrors, contoured mirrors, and very thin solid mirrors. These mirrors were then categorized and weight to diameter ratio was plotted to find a best fit curve for each case. A best fitting curve program tests nineteen different equations and ranks a 'goodness of fit' for each of these equations. The resulting relationship found for each light-weight mirror category helps to quantify light-weight optical systems and methods of fabrication and provides comparisons between mirror types.

  16. Research of the small satellite data management system

    NASA Astrophysics Data System (ADS)

    Yu, Xiaozhou; Zhou, Fengqi; Zhou, Jun

    2007-11-01

    Small satellite is the integration of light weight, small volume and low launch cost. It is a promising approach to realize the future space mission. A detailed study of the data management system has been carried out, with using new reconfiguration method based on System On Programmable Chip (SOPC). Compared with common structure of satellite, the Central Terminal Unit (CTU), the Remote Terminal Unit (RTU) and Serial Data Bus (SDB) of the data management are all integrated in single chip. Thus the reliability of the satellite is greatly improved. At the same time, the data management system has powerful performance owing to the modern FPGA processing ability.

  17. Compact Efficient Lidar Receiver for Measuring Atmospheric Aerosols

    NASA Technical Reports Server (NTRS)

    Gili, Christopher; De Young, Russell

    2006-01-01

    A small, light weight, and efficient aerosol lidar receiver was constructed and tested. Weight and space savings were realized by using rigid optic tubes and mounting cubes to package the steering optics and detectors in a compact assembly. The receiver had a 1064nm channel using an APD detector. The 532nm channel was split (90/10) into an analog channel (90%) and a photon counting channel (10%). The efficiency of the 1064nm channel with optical filter was 44.0%. The efficiency of the analog 532nm channel was 61.4% with the optical filter, and the efficiency of the 532nm photon counting channel was 7.6% with the optical filter. The results of the atmospheric tests show that the detectors were able to consistently return accurate results. The lidar receiver was able to detect distinct cloud layers, and the lidar returns also agreed across the different detectors. The use of a light weight fiber-coupled telescope reduced weight and allowed great latitude in detector assembly positioning due to the flexibility enabled by the use of fiber optics. The receiver is now ready to be deployed for aircraft or ground based aerosol lidar measurements.

  18. Study on a practical robotic follower to support home oxygen therapy patients--questionnaire-based concept evaluation by the patients-.

    PubMed

    Endo, Gen; Iemura, Yu; Fukushima, Edwardo F; Hirose, Shigeo; Iribe, Masatsugu; Ikeda, Ryota; Onishi, Kohei; Maeda, Naoto; Takubo, Toshio; Ohira, Mineko

    2013-06-01

    Home oxygen therapy (HOT) is a medical treatment for the patients suffering from severe lung diseases. Although walking outdoors is recommended for the patients to maintain physical strength, the patients always have to carry a portable oxygen supplier which is not sufficiently light weight for this purpose. Our ultimate goal is to develop a mobile robot to carry an oxygen tank and follow a patient in an urban outdoor environment. We have proposed a mobile robot with a tether interface to detect the relative position of the foregoing patient. In this paper, we report the questionnaire-based evaluation about the two developed prototypes by the HOT patients. We conduct maneuvering experiments, and then obtained questionnaire-based evaluations from the 20 patients. The results show that the basic following performance is sufficient and the pulling force of the tether is sufficiently small for the patients. Moreover, the patients prefer the small-sized prototype for compactness and light weight to the middle-sized prototype which can carry larger payload. We also obtained detailed requests to improve the robots. Finally the results show the general concept of the robot is favorably received by the patients.

  19. [Effect of chronic intake of dietary fiber complex on the intestinal structure and function in hypercholesterolemic rats].

    PubMed

    Ma, Zhengwei; Zhang, Xizhong

    2003-07-01

    To investigate the long-term effect of dietary fiber complex (DFC) on intestinal structure and function in hypercholesterolemic rats, 60 healthy SD rats were feed with food rich in lipids and hypercholesterolemic animal models were established. The animals were randomly divided into 5 groups. Rats were fed DFC at levels of 4%, 16%, or 64% for three month in the experimental groups. Wheat fiber was used in the hypercholesterolemic control (HC) group and rats feeding on normal food were used as normal control (NC). Morphology of the small intestine, reticum and caecum were observed by light and electron microscope examination. Intestinal function was measured physically. The results showed that (1) compared with NC group, fecal weight was significantly raised in DFC group of higher level (group D and E, P < 0.05); (2) the weights of small intestine wall in D and E group were significantly higher than those of NC and HC group and weights of caecum wall in E group were significantly higher than those of NC and HC group (P < 0.05); (3) widen villi and thickened muscle layer of small intestine were observed in DFC group of higher level. No demonstrable changes in reticulum morphology in any group of animals were found under the observation of light microscope (4) microvilla becoming short and/or absent, mitochondria swelling, impairment of the integrity of the cristae were commonly observed in DFC groups. Conclusions Long-term intake of DFC composed mainly of Hippophae rhamnoides L, Bran, oat bran and guar gum at higher levels might induce some morphological changes of intestine and caecum. Therefore, DFC might be used at low level as an effective cholesterol-lowering agent.

  20. Mars Sample Return mission utilizing in-situ propellant production

    NASA Technical Reports Server (NTRS)

    Zubrin, Robert; Price, Steve

    1995-01-01

    This report presents the results of a study examining the potential of in-situ propellant production (ISPP) on Mars to aid in achieving a low cost Mars Sample Return (MSR) mission. Two versions of such a mission were examined: a baseline version employing a dual string spacecraft, and a light weight version employing single string architecture with selective redundancy. Both systems employed light weight avionics currently being developed by Lockheed Martin, Jet Propulsion Lab and elsewhere in the aerospace community, both used a new concept for a simple, light weight parachuteless sample return capsule, both used a slightly modified version of the Mars Surveyor lander currently under development at Lockheed Martin for flight in 1998, and both used a combination of the Sabatier-electrolysis and reverse water gas shift ISPP systems to produce methane/oxygen propellant on Mars by combining a small quantity of imported hydrogen with the Martian CO2 atmosphere. It was found that the baseline mission could be launched on a Delta 7925 and return a 0.5 kg sample with 82 percent mission launch margin;over and beyond subsystem allocated contingency masses . The lightweight version could be launched on a Mid-Lite vehicle and return a 0.25 kg sample with 11 percent launch margin, over and above subsystem contingency mass allocations.

  1. Design and stray light analysis of ultra-thin geometrical waveguide

    NASA Astrophysics Data System (ADS)

    Wang, Qiwei; Cheng, Dewen; Hou, Qichao; Hu, Yuan; Wang, Yongtian

    2015-08-01

    Nowadays, the waveguide has the advantages of small thickness and light weight so that it attracts more and more attention in the field of near-eye display. However, as a major problem, stray lights generated in the waveguide seriously degrade the display quality. In this paper, a geometrical waveguide with a beam-splitting mirror array (BSMA) is designed by using the non-sequential ray-tracing software LightTools, and great efforts are paid to study the causes and solutions of the stray light. With mass calculation and optimization based on the criterion of stray light/useful light ratio, an optimum design with the least amount of stray lights is found. To further eliminate the stray light, a novel structure that couples the rays into the waveguide is designed. The optimized waveguide has a FOV of 36° in the pupil-expanding direction of the waveguide, with stray light energy reduced to 1% over the useful light, the exit pupil diameter is 11.6mm at an eye relief of 20mm and the thickness is 2.4mm.

  2. A portable high power microwave source with permanent magnets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Wei; Zhang, Jun; Li, Zhi-qiang

    A high power microwave source with permanent magnets is proposed in this paper. The source has the length 330 mm, maximum diameter 350 mm, and total weight 50 kg, including 25 kg of permanent magnets. 1 GW of microwave power with Gaussian radiation pattern and 24% of microwave power generation efficiency in a pulse duration of 75 ns are obtained in the experiment. Operating frequency of the source is 2.32 GHz. Such a small size, light weight, and highly stable in operation source will be used in portable repetitive high power microwave generation systems.

  3. 46 CFR 160.171-9 - Construction.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... (110 lb.) to 150 kg (330 lb.) and in height from 1.5 m (59 in.) to 1.9 m (75 in.). Each child size suit must fit children or small adults ranging in weight from 20 kg (44 lb.) to 50 kg (110 lb.) and in... shoulder area and so that the light when attached does not damage the suit and cannot adversely affect its...

  4. 46 CFR 160.171-9 - Construction.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (110 lb.) to 150 kg (330 lb.) and in height from 1.5 m (59 in.) to 1.9 m (75 in.). Each child size suit must fit children or small adults ranging in weight from 20 kg (44 lb.) to 50 kg (110 lb.) and in... shoulder area and so that the light when attached does not damage the suit and cannot adversely affect its...

  5. 46 CFR 160.171-9 - Construction.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... (110 lb.) to 150 kg (330 lb.) and in height from 1.5 m (59 in.) to 1.9 m (75 in.). Each child size suit must fit children or small adults ranging in weight from 20 kg (44 lb.) to 50 kg (110 lb.) and in... shoulder area and so that the light when attached does not damage the suit and cannot adversely affect its...

  6. Closing the Gap Between Research and Field Applications for Multi-UAV Cooperative Missions

    DTIC Science & Technology

    2013-09-01

    IMU Inertial Measurement Units INCOSE International Council on Systems Engineering ISR Intelligence Surveillance and Reconnaissance ISTAR...light-weight and low-cost inertial measurement units ( IMUs ) are widely adopted for navigation of small- scale UAVs. Low-costs IMUs are characterized...by high measurement noises and large measurement biases. Hence pure initial navigation using low-cost IMUs drifts rapidly. In practice, inertial

  7. Photolithographic patterning of vacuum-deposited organic light emitting devices

    NASA Astrophysics Data System (ADS)

    Tian, P. F.; Burrows, P. E.; Forrest, S. R.

    1997-12-01

    We demonstrate a photolithographic technique to fabricate vacuum-deposited organic light emitting devices. Photoresist liftoff combined with vertical deposition of the emissive organic materials and the metal cathode, followed by oblique deposition of a metal cap, avoids the use of high processing temperatures and the exposure of the organic materials to chemical degradation. The unpackaged devices show no sign of deterioration in room ambient when compared with conventional devices fabricated using low-resolution, shadow mask patterning. Furthermore, the devices are resistant to rapid degradation when operated in air for extended periods. This work illustrates a potential foundation for the volume production of very high-resolution, full color, flat panel displays based on small molecular weight organic light emitting devices.

  8. A Dual Polarization, Active, Microstrip Antenna for an Orbital Imaging Radar System Operating at L-Band

    NASA Technical Reports Server (NTRS)

    Kelly, Kenneth C.; Huang, John

    1999-01-01

    A highly successful Earth orbiting synthetic antenna aperture radar (SAR) system, known as the SIR-C mission, was carried into orbit in 1994 on a U.S. Shuttle (Space Transportation System) mission. The radar system was mounted in the cargo bay with no need to fold, or in any other way reduce the size of the antennas for launch. Weight and size were not limited for the L-Band, C-Band, and X-Band radar systems of the SIR-C radar imaging mission; the set of antennas weighed 10,500 kg, the L-Band antenna having the major share of the weight. This paper treats designing an L-Band antenna functionally similar to that used for SIR-C, but at a fraction of the cost and at a weight in the order of 250 kg. Further, the antenna must be folded to fit into the small payload shroud of low cost booster rocket systems. Over 31 square meters of antenna area is required. This low weight, foldable, electronic scanning antenna is for the proposed LightSAR radar system which is to be placed in Earth orbit on a small, dedicated space craft at the lowest possible cost for an efficient L-Band radar imaging system. This LightSAR spacecraft radar is to be continuously available for at least five operational years, and have the ability to map or repeat-map any area on earth within a few days of any request. A microstrip patch array, with microstrip transmission lines heavily employed in the aperture and in the corporate feed network, was chosen as the low cost approach for this active dual-polarization, 80 MHz (6.4%) bandwidth antenna design.

  9. A Dual Polarization, Active, Microstrip Antenna for an Orbital Imaging Radar System Operating at L-Band

    NASA Technical Reports Server (NTRS)

    Kelly, Kenneth C.; Huang, John

    2000-01-01

    A highly successful Earth orbiting synthetic antenna aperture radar (SAR) system, known as the SIR-C mission, was carried into orbit in 1994 on a U.S. Shuttle (Space Transportation System) mission. The radar system was mounted in the cargo bay with no need to fold, or in any other way reduce the size of the antennas for launch. Weight and size were not limited for the L-Band, C-Band, and X-Band radar systems of the SIR-C radar imaging mission; the set of antennas weighed 10,500 kg, the L-Band antenna having the major share of the weight. This paper treats designing an L-Band antenna functionally similar to that used for SIR-C, but at a fraction of the cost and at a weight in the order of 250 kg. Further, the antenna must be folded to fit into the small payload shroud of low cost booster rocket systems. Over 31 square meters of antenna area is required. This low weight, foldable, electronic scanning antenna is for the proposed LightSAR radar system which is to be placed in Earth orbit on a small, dedicated space craft at the lowest possible cost for an efficient L- Band radar imaging system. This LightSAR spacecraft radar is to be continuously available for at least five operational years, and have the ability to map or repeat-map any area on earth within a few days of any request. A microstrip patch array, with microstrip transmission lines heavily employed in the aperture and in the corporate feed network, was chosen as the low cost approach for this active dual-polarization, 80 MHz (6.4%) bandwidth antenna design.

  10. Omnidirectional fiber optic tiltmeter

    DOEpatents

    Benjamin, B.C.; Miller, H.M.

    1983-06-30

    A tiltmeter is provided which is useful in detecting very small movements such as earth tides. The device comprises a single optical fiber, and an associated weight affixed thereto, suspended from a support to form a pendulum. A light source, e.g., a light emitting diode, mounted on the support transmits light through the optical fiber to a group of further optical fibers located adjacent to but spaced from the free end of the single optical fiber so that displacement of the single optical fiber with respect to the group will result in a change in the amount of light received by the individual optical fibers of the group. Photodetectors individually connectd to the fibers produce corresponding electrical outputs which are differentially compared and processed to produce a resultant continuous analog output representative of the amount and direction of displacement of the single optical fiber.

  11. Back-pack unit for capturing waterfowl and upland game by night-lighting

    USGS Publications Warehouse

    Drewien, R.C.; Reeves, H.M.; Springer, P.F.; Kuck, T.L.

    1967-01-01

    A night-lighting unit, designed as a light weight back-pack, proved successful for capturing waterfowl pairs, pheasants (Phasianus colchicus), and cottontail rabbits (Sylvilagus floridanus) during the spring and summer when most breeding populations are widely dispersed. Eighty ducks of seven species were captured in 48 hours (1.7 ducks per hour) of night-lighting in marsh habitat. Similarly, 30 pheasants were trapped in 25 hours (1.2 birds per hour) and 63 cottontail rabbits were either observed at close range (6-12 ft) or captured during night-lighting operations in upland habitat. Catch per hour of effort increased for all species as their night habitat requirements and reaction to night-lights became known. The mobile unit proved well suited for intensive use on small areas where other methods of capture were unfeasible and where representative coverage of various habitat types was desired. Besides its utility for capturing animals, the unit provided a method for studying nocturnal movements, behavior, and habitat use of marked animals.

  12. The Influence of Non-Nociceptive Factors on Hot Plate Latency in Rats

    PubMed Central

    Gunn, Amanda; Bobeck, Erin N.; Weber, Ceri; Morgan, Michael M.

    2010-01-01

    The hot plate is a widely used test to assess nociception. The effect of non-nociceptive factors (weight, sex, activity, habituation, and repeated testing) on hot plate latency was examined. Comparison of body weight and hot plate latency revealed a small but significant inverse correlation (light rats had longer latencies). Habituating rats to the test room for 1 hr prior to testing did not decrease hot plate latency except for female rats tested on Days 2 - 4. Hot plate latency decreased with repeated daily testing, but this was not caused by a decrease in locomotor activity or learning to respond. Activity on the hot plate was consistent across all four trials, and prior exposure to a room temperature plate caused a similar decrease in latency as rats tested repeatedly on the hot plate. Despite this decrease in baseline hot plate latency, there was no difference in morphine antinociceptive potency. The present study shows that weight, habituation to the test room, and repeated testing can alter baseline hot plate latency, but these effects are small and have relatively little impact on morphine antinociception. PMID:20797920

  13. Concepts for the development of light-weight composite structures for rotor burst containment

    NASA Technical Reports Server (NTRS)

    Holms, A. G.

    1977-01-01

    Published results on rotor burst containment with single materials, and on body armor using composite materials were used to establish a set of hypotheses about what variables might control the design of a weight-efficient protective device. Based on modern concepts for the design and analysis of small optimum seeking experiments, a particular experiment for evaluating the hypotheses and materials was designed. The design and methods for the analysis of results are described. The consequence of such hypotheses is that the device should consist of as many as four concentric rings, each to consist of a material uniquely chosen for its position in the penetration sequence.

  14. [Effects of the spaceflight on organ-development in the neonatal rats: results in the Neurolab (STS-90)].

    PubMed

    Miyake, Masao; Yamasaki, Masao; Katahira, Kiyoaki; Waki, Hidefumi; Katsuda, Shin-ichiro; Ijiri, Kenichi; Shimizu, Tsuyoshi

    2002-11-01

    In the Neurolab mission, we found that spaceflight affects the development of the aortic baroreflex system and the body weight of the flight rats was significantly lighter [correction of lightess] than that of the control group. The aim of this study is to examine the structural and functional development in various tissues and organs. One hundred and eighteen nine-day old rats and seven fifteen-day old rats, which were launched at these ages and nursed by their dams in the space shuttle Columbia for 16 days, were served for this study. Two hundred and twenty one neonates were used as the ground controls (VIV: vivarium and AGC: asynchronous ground controls). On the landing day after they returned to the earth, the rats were perfused with a fixative under deep urethane anesthesia, and the organs were weighed and the ratio of the organ weight to the body weight was calculated. Six animals of the nine-day old group were reared on the ground for 30 more days after landing and also examined in the same protocol as the landing-day-examination. The organs obtained to examine were heart, lung, spleen, thymus, adrenal glands, kidney, liver, small intestine, large intestine, mesentery, pancreas, testis and ovary. Paraffin sections were made from some organ tissues and prepared for HE staining and immunohistochemistry. We compared these organs in the flight rat with those in the ground controls. All organs except the lung of nine-day old group were significantly smaller. In the ratio of organ weight to body weight, the lung and heart were significantly larger. The weight and ratio of the liver showed no significant difference. The thymus, spleen, mesentery and pancreas were smaller in the weight and the ratio. There were no differences in the body weight among 30-day reared groups, but the lung in the flight group is significantly heavier than the control groups and thymus also tends to be relatively heavy. In flight rats of the fifteen-day group, the kidney was heavy and the ovary was light as compared to the controls. The adipose tissue was macroscopically little found around the thoracic and abdominal organs in all rats of the flight group. These results suggest that the organs related to oxygen supply like as the lung and heart have priority in development over the mesentery and immune system organs even during spaceflight. Lightness of the mesentery in space rats is due to small contents of adipose tissues, and may reflect amounts of the food taken by the flight dams. Lightness of the organs like as the thymus, spleen and pancreas suggests that spaceflight may affect the immune system and also affect continuously the lung and thymus development even after landing.

  15. Defense Small Business Innovation Research Program (SBIR) FY 1984.

    DTIC Science & Technology

    1984-01-12

    nuclear submarine non-metallic, light weight, high strength piping . Includes the development of adequate fabrication procedures for attaching pipe ...waste heat economizer methods, require development. Improved conventional and hybrid heat pipes and/or two phase transport devices 149 IF are required...DESCRIPTION: A need exists to conceive, design, fabricate and test a method of adjusting the length of the individual legs of nylon or Kevlar rope sling

  16. Gain weight by “going diet?” Artificial sweeteners and the neurobiology of sugar cravings

    PubMed Central

    Yang, Qing

    2010-01-01

    America’s obesity epidemic has gathered much media attention recently. A rise in the percent of the population who are obese coincides with an increase in the widespread use of non-caloric artificial sweeteners, such as aspartame (e.g., Diet Coke) and sucralose (e.g., Pepsi One), in food products (Figure 1). Both forward and reverse causalities have been proposed [1,2]. While people often choose “diet” or “light” products to lose weight, research studies suggest that artificial sweeteners may contribute to weight gain. In this mini-review, inspired by a discussion with Dr. Dana Small at Yale’s Neuroscience 2010 conference in April, I first examine the development of artificial sweeteners in a historic context. I then summarize the epidemiological and experimental evidence concerning their effects on weight. Finally, I attempt to explain those effects in light of the neurobiology of food reward. PMID:20589192

  17. High-temperature oxidation behavior of reaction-formed silicon carbide ceramics

    NASA Technical Reports Server (NTRS)

    Ogbuji, Linus U. J. T.; Singh, M.

    1995-01-01

    The oxidation behavior of reaction-formed silicon carbide (RFSC) ceramics was investigated in the temperature range of 1100 to 1400 C. The oxidation weight change was recorded by TGA; the oxidized materials were examined by light and electron microscopy, and the oxidation product by x-ray diffraction analysis (XRD). The materials exhibited initial weight loss, followed by passive weight gain (with enhanced parabolic rates, k(sub p)), and ending with a negative (logarithmic) deviation from the parabolic law. The weight loss arose from the oxidation of residual carbon, and the enhanced k(sub p) values from internal oxidation and the oxidation of residual silicon, while the logarithmic kinetics is thought to have resulted from crystallization of the oxide. The presence of a small amount of MoSi, in the RFSC material caused a further increase in the oxidation rate. The only solid oxidation product for all temperatures studied was silica.

  18. Distributed fiber-optic laser-ultrasound generation based on ghost-mode of tilted fiber Bragg gratings.

    PubMed

    Tian, Jiajun; Zhang, Qi; Han, Ming

    2013-03-11

    Active ultrasonic testing is widely used for medical diagnosis, material characterization and structural health monitoring. Ultrasonic transducer is a key component in active ultrasonic testing. Due to their many advantages such as small size, light weight, and immunity to electromagnetic interference, fiber-optic ultrasonic transducers are particularly attractive for permanent, embedded applications in active ultrasonic testing for structural health monitoring. However, current fiber-optic transducers only allow effective ultrasound generation at a single location of the fiber end. Here we demonstrate a fiber-optic device that can effectively generate ultrasound at multiple, selected locations along a fiber in a controllable manner based on a smart light tapping scheme that only taps out the light of a particular wavelength for laser-ultrasound generation and allow light of longer wavelengths pass by without loss. Such a scheme may also find applications in remote fiber-optic device tuning and quasi-distributed biochemical fiber-optic sensing.

  19. Banana Resistant Starch and Its Effects on Constipation Model Mice

    PubMed Central

    Wang, Juan; Huang, Ji Hong; Cheng, Yan Feng

    2014-01-01

    Abstract Banana resistant starch (BRS) was extracted to investigate the structural properties of BRS, its effects on the gastrointestinal transit, and dejecta of normal and experimentally constipated mice. The mouse constipation model was induced by diphenoxylate administration. The BRS administered mice were divided into three groups and gavaged with 1.0, 2.0, or 4.0 g/kg body weight BRS per day. The small intestinal movement, time of the first black dejecta, dejecta granules, weight and their moisture content, body weight, and food intake of mice were studied. Results showed that the BRS particles were oval and spindly and some light cracks and pits were in the surface. The degree of crystallinity of BRS was 23.13%; the main diffraction peaks were at 2θ 15.14, 17.38, 20.08, and 22.51. The degree of polymerization of BRS was 81.16 and the number-average molecular weight was 13147.92 Da, as determined by the reducing terminal method. In animal experiments, BRS at the dose of 4.0 g/kg body weight per day was able to increase the gastrointestinal propulsive rate, and BRS at the doses of 2.0 and 4.0 g/kg body weight per day was found to shorten the start time of defecation by observing the first black dejecta exhaust. However, there were no influences of BRS on the dejecta moisture content, the dejecta granules and their weight, body weight, or daily food intake in mice. BRS was effective in accelerating the movement of the small intestine and in shortening the start time of defecation, but did not impact body weight and food intake. Therefore, BRS had the potential to be useful for improving intestinal motility during constipation. PMID:25046686

  20. Large-area, flexible imaging arrays constructed by light-charge organic memories

    PubMed Central

    Zhang, Lei; Wu, Ti; Guo, Yunlong; Zhao, Yan; Sun, Xiangnan; Wen, Yugeng; Yu, Gui; Liu, Yunqi

    2013-01-01

    Existing organic imaging circuits, which offer attractive benefits of light weight, low cost and flexibility, are exclusively based on phototransistor or photodiode arrays. One shortcoming of these photo-sensors is that the light signal should keep invariant throughout the whole pixel-addressing and reading process. As a feasible solution, we synthesized a new charge storage molecule and embedded it into a device, which we call light-charge organic memory (LCOM). In LCOM, the functionalities of photo-sensor and non-volatile memory are integrated. Thanks to the deliberate engineering of electronic structure and self-organization process at the interface, 92% of the stored charges, which are linearly controlled by the quantity of light, retain after 20000 s. The stored charges can also be non-destructively read and erased by a simple voltage program. These results pave the way to large-area, flexible imaging circuits and demonstrate a bright future of small molecular materials in non-volatile memory. PMID:23326636

  1. Fabrication of Organic Thin Film Transistors Using Layer-By-Layer Assembly (Preprint)

    DTIC Science & Technology

    2007-03-01

    thin-film transistors ( TFTs ) have received considerable attention as a low- cost, light-weight, flexible alternative to traditional amorphous silicon...Previous studies have investigated the use of a number of materials for both the active layer and the gate dielectric in various TFT architectures. These...performance. Conjugated small molecules, such as pentacene, or polymers, such as poly(3- hexylthiophene), are commonly used as the active layer in organic TFT

  2. Compact Plasma Accelerator for Micropropulsion Applications

    NASA Technical Reports Server (NTRS)

    Foster, John E.

    2001-01-01

    There is a need for a low power, light-weight (compact), high specific impulse electric propulsion device to satisfy mission requirements for microsatellite (1 to 20 kg) class missions. Satisfying these requirements entails addressing the general problem of generating a sufficiently dense plasma within a relatively small volume and then accelerating it. In the work presented here, the feasibility of utilizing a magnetic cusp to generate a dense plasma over small length scales of order 1 mm is investigated. This approach could potentially mitigate scaling issues associated with conventional ion thruster plasma containment schemes. Plume and discharge characteristics were documented using a Faraday probe and a retarding potential analyzer.

  3. Literature Review of Shear Performance of Light-weight Steel Framing Wall Panels

    NASA Astrophysics Data System (ADS)

    Zhang, Zhuangnan; Liu, Shen; Liu, Hong

    2018-03-01

    In this paper, a comprehensive review of light-weight steel framing wall panels was carried out. The structure and force characteristics of light-weight steel framing wall panels were introduced. The testing and theoretical research results on the shear behaviour of light-weight steel framing wall panels were summarized in the domestic and foreign. And combined with the existing standards in China, the author's views and ideas are put forward to the problems in the research field of this kind of structural system.

  4. Fuel cell powered small unmanned aerial systems (UASs) for extended endurance flights

    NASA Astrophysics Data System (ADS)

    Chu, Deryn; Jiang, R.; Dunbar, Z.; Grew, Kyle; McClure, J.

    2015-05-01

    Small unmanned aerial systems (UASs) have been used for military applications and have additional potential for commercial applications [1-4]. For the military, these systems provide valuable intelligence, surveillance, reconnaissance and target acquisition (ISRTA) capabilities for units at the infantry, battalion, and company levels. The small UASs are light-weight, manportable, can be hand-launched, and are capable of carrying payloads. Currently, most small UASs are powered by lithium-ion or lithium polymer batteries; however, the flight endurance is usually limited less than two hours and requires frequent battery replacement. Long endurance small UAS flights have been demonstrated through the implementation of a fuel cell system. For instance, a propane fueled solid oxide fuel cell (SOFC) stack has been used to power a small UAS and shown to extend mission flight time. The research and development efforts presented here not only apply to small UASs, but also provide merit to the viability of extending mission operations for other unmanned systems applications.

  5. Flocculation and aggregation in a microgravity environment (FAME)

    NASA Technical Reports Server (NTRS)

    Ansari, Rafat R.; Dhadwal, Harbans S.; Suh, Kwang I.

    1994-01-01

    An experiment to study flocculation phenomena in the constrained microgravity environment of a space shuttle or space station is described. The small size and light weight experiment easily fits in a Spacelab Glovebox. Using an integrated fiber optic dynamic light scattering (DLS) system we obtain high precision particle size measurements from dispersions of colloidal particles within seconds, needs no onboard optical alignment, no index matching fluid, and offers sample mixing and shear melting capabilities to study aggregation (flocculation and coagulation) phenomena under both quiescent and controlled agitation conditions. The experimental system can easily be adapted for other microgravity experiments requiring the use of DLS. Preliminary results of ground-based study are reported.

  6. Use of an improved radiation amplification factor to estimate the effect of total ozone changes on action spectrum weighted irradiances and an instrument response function

    NASA Astrophysics Data System (ADS)

    Herman, Jay R.

    2010-12-01

    Multiple scattering radiative transfer results are used to calculate action spectrum weighted irradiances and fractional irradiance changes in terms of a power law in ozone Ω, U(Ω/200)-RAF, where the new radiation amplification factor (RAF) is just a function of solar zenith angle. Including Rayleigh scattering caused small differences in the estimated 30 year changes in action spectrum-weighted irradiances compared to estimates that neglect multiple scattering. The radiative transfer results are applied to several action spectra and to an instrument response function corresponding to the Solar Light 501 meter. The effect of changing ozone on two plant damage action spectra are shown for plants with high sensitivity to UVB (280-315 nm) and those with lower sensitivity, showing that the probability for plant damage for the latter has increased since 1979, especially at middle to high latitudes in the Southern Hemisphere. Similarly, there has been an increase in rates of erythemal skin damage and pre-vitamin D3 production corresponding to measured ozone decreases. An example conversion function is derived to obtain erythemal irradiances and the UV index from measurements with the Solar Light 501 instrument response function. An analytic expressions is given to convert changes in erythemal irradiances to changes in CIE vitamin-D action spectrum weighted irradiances.

  7. Use of an Improved Radiation Amplification Factor to Estimate the Effect of Total Ozone Changes on Action Spectrum Weighted Irradiances and an Instrument Response Function

    NASA Technical Reports Server (NTRS)

    Herman, Jay R.

    2010-01-01

    Multiple scattering radiative transfer results are used to calculate action spectrum weighted irradiances and fractional irradiance changes in terms of a power law in ozone OMEGA, U(OMEGA/200)(sup -RAF), where the new radiation amplification factor (RAF) is just a function of solar zenith angle. Including Rayleigh scattering caused small differences in the estimated 30 year changes in action spectrum-weighted irradiances compared to estimates that neglect multiple scattering. The radiative transfer results are applied to several action spectra and to an instrument response function corresponding to the Solar Light 501 meter. The effect of changing ozone on two plant damage action spectra are shown for plants with high sensitivity to UVB (280-315 run) and those with lower sensitivity, showing that the probability for plant damage for the latter has increased since 1979, especially at middle to high latitudes in the Southern Hemisphere. Similarly, there has been an increase in rates of erythemal skin damage and pre-vitamin D3 production corresponding to measured ozone decreases. An example conversion function is derived to obtain erythemal irradiances and the UV index from measurements with the Solar Light 501 instrument response function. An analytic expressions is given to convert changes in erythemal irradiances to changes in CIE vitamin-D action spectrum weighted irradiances.

  8. Small Molecular Weight Soybean Protein-Derived Peptides Nutriment Attenuates Rat Burn Injury-Induced Muscle Atrophy by Modulation of Ubiquitin-Proteasome System and Autophagy Signaling Pathway.

    PubMed

    Zhao, Fen; Yu, Yonghui; Liu, Wei; Zhang, Jian; Liu, Xinqi; Liu, Lingying; Yin, Huinan

    2018-03-21

    This article describes results of the effect of dietary supplementation with small molecular weight soybean protein-derived peptides on major rat burn injury-induced muscle atrophy. As protein nutrients have been previously implicated to play an important role in improving burn injury outcomes, optimized more readily absorbed small molecular weight soybean protein-derived peptides were evaluated. Thus, the quantity, sodium dodecyl sulfate polyacrylamide-gel electrophoresis patterns, molecular weight distribution, and composition of amino acids of the prepared peptides were analyzed, and a major full-thickness 30% total body surface area burn-injury rat model was utilized to assess the impact of supplementation with soybean protein-derived peptides on initial systemic inflammatory responses as measured by interferon-gamma (IFN-γ), chemokine (C-C motif) ligand 2 (CCL2, also known as MCP-1), chemokine (C-C motif) ligand 7 (CCL7, also known as MCP-3), and generation of muscle atrophy as measured by tibialis anterior muscle (TAM) weight relative to total body weight. Induction of burn injury-induced muscle atrophy ubiquitin-proteasome system (UPS) signaling pathways in effected muscle tissues was determined by Western blot protein expression measurements of E3 ubiquitin-protein ligase TRIM-63 (TRIM63, also known as MuRF1) and F-box only protein 32 (FBXO32, also known as atrogin-1 or MAFbx). In addition, induction of burn injury-induced autophagy signaling pathways associated with muscle atrophy in effected muscle tissues was assessed by immunohistochemical analysis as measured by microtubule-associated proteins 1 light chain 3 (MAP1LC3, or commonly abbreviated as LC3) and beclin-1 (BECN1) expression, as well as relative induction of cytoplasmic-liberated form of MAP1LC3 (LC3-I) and phagophore and autophagosome membrane-bound form of MAP1LC3 (LC3-II), and BECN1 protein expression by Western blot analysis. Nutrient supplementation with small molecular weight soybean protein-derived peptides resulted a significant reduction in burn injury-induced inflammatory markers, muscle atrophy, induction of TRIM63 and FBXO32 muscle atrophy signaling pathways, and induction of autophagy signaling pathways LC3 and BECN1 associated with muscle atrophy. These results implicated that small molecular weight soybean-derived peptides dietary supplementation could be used as an adjunct therapy in burn injury management to reduce the development or severity of muscle atrophy for improved burn patient outcomes.

  9. Melatonin and exposure to constant light/darkness affects ovarian follicular kinetics and estrous cycle in Indian desert gerbil Meriones hurrianae.

    PubMed

    Sinhasane, S V; Joshi, B N

    1997-12-01

    Melatonin mediates photoperiodic influence on reproduction and constant light and darkness affect pineal biosynthesis of melatonin. The present study was undertaken to assess the effects of melatonin and drastic photoperiodic changes on reproduction in a tropical desert species with a fossorial lifestyle. Ovarian follicular kinetics and estrous cycle were studied in the Indian desert gerbil Meriones hurrianae, after treatment with melatonin and exposure to constant light (LL) and darkness (DD) regimes. Melatonin treatment increased (P < 0.001) ovarian weights without changing the uterine weights. While exposure to LL decreased (P < 0.001) both ovarian and uterine weights, exposure to DD had no effect on these weights. Follicular kinetics of growing and regressing follicles revealed that ovaries of melatonin-treated and DD-exposed animals had significantly more growing follicles. Melatonin treatment increased all types of growing follicles, especially antral and Graafian follicles. Exposure to DD increased all types of growing follicles, with the medium sized antral and Graafian follicles being significant (P < 0.01). In contrast to stimulation of follicular growth by melatonin and DD, LL caused regression of all stages of follicular growth and also reduced the number of small preantral follicles. Melatonin treatment increased (P < 0.001) the length of estrous cycle (5.08 to 7.29 days). Gerbils treated with melatonin, exposed to LL and DD, had a longer (P < 0.001) metestrus. Animals held in LL, had the least number (P < 0.001) of estrous smears (1 in 30 days). The results suggest that melatonin is involved in growth of ovarian follicles in the Indian desert gerbil. Copyright 1997 Academic Press.

  10. Surgical guidance system using hand-held probe with accompanying positron coincidence detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Majewski, Stanislaw; Weisenberger, Andrew G.

    A surgical guidance system offering different levels of imaging capability while maintaining the same hand-held convenient small size of light-weight intra-operative probes. The surgical guidance system includes a second detector, typically an imager, located behind the area of surgical interest to form a coincidence guidance system with the hand-held probe. This approach is focused on the detection of positron emitting biomarkers with gamma rays accompanying positron emissions from the radiolabeled nuclei.

  11. Propulsion and Power Supplies for Unmanned Vehicles. Volume I. Engines for Small Propeller-Driven RPVS

    DTIC Science & Technology

    1977-11-01

    residual unbaiance. Mass production experience and availability of rotary piston engines -type WANKEL- refer basically to the automobile industry...production air cooled automobile engine in standard form can be ruled out on a specific weight basis. 4. In modified form, as used in many light aircr: Ct...the air cooled automobile engine appears to be a possibility. Availability, lcw initial cost; and good specific fuel consumption could make the unit

  12. Changes in pigment, spectral transmission and element content of pink chicken eggshells with different pigment intensity during incubation.

    PubMed

    Yu, Yue; Li, Zhanming; Pan, Jinming

    2016-01-01

    Objective. The objective of this study was to investigate changes in pigment, spectral transmission and element content of chicken eggshells with different intensities of pink pigment during the incubation period. We also investigated the effects of the region (small pole, equator and large pole) and pink pigment intensity of the chicken eggshell on the percent transmission of light passing through the chicken eggshells. Method. Eggs of comparable weight from a meat-type breeder (Meihuang) were used, and divided based on three levels of pink pigment (light, medium and dark) in the eggshells. During the incubation (0-21 d), the values of the eggshell pigment (ΔE, L (∗), a (∗), b (∗)) were measured. The percent transmission of light for different regions and intensities of eggshell pigmentation was measured by using the visible wavelength range of 380-780 nm. Result. Three measured indicators of eggshell color, ΔE, L (∗) and a (∗), did not change significantly during incubation. Compared with other regions and pigment intensities, eggshell at the small pole and with light pigmentation intensity showed the highest percent transmission of light. The transmission value varied significantly (P < 0.001) with incubation time. The element analysis of eggshells with different levels of pink pigment showed that the potassium content of the eggshells for all pigment levels decreased significantly during incubation. Conclusion. In summary, pigment intensity and the region of the eggshell influenced the percent transmission of light of eggshell. Differences in the spectral characteristics of different eggshells may influence the effects of photostimulation during the incubation of eggs. All of these results will be applicable for perfecting the design of light intensity for lighted incubation to improve productivity.

  13. Changes in pigment, spectral transmission and element content of pink chicken eggshells with different pigment intensity during incubation

    PubMed Central

    Yu, Yue; Li, Zhanming

    2016-01-01

    Objective. The objective of this study was to investigate changes in pigment, spectral transmission and element content of chicken eggshells with different intensities of pink pigment during the incubation period. We also investigated the effects of the region (small pole, equator and large pole) and pink pigment intensity of the chicken eggshell on the percent transmission of light passing through the chicken eggshells. Method. Eggs of comparable weight from a meat-type breeder (Meihuang) were used, and divided based on three levels of pink pigment (light, medium and dark) in the eggshells. During the incubation (0–21 d), the values of the eggshell pigment (ΔE, L∗, a∗, b∗) were measured. The percent transmission of light for different regions and intensities of eggshell pigmentation was measured by using the visible wavelength range of 380–780 nm. Result. Three measured indicators of eggshell color, ΔE, L∗ and a∗, did not change significantly during incubation. Compared with other regions and pigment intensities, eggshell at the small pole and with light pigmentation intensity showed the highest percent transmission of light. The transmission value varied significantly (P < 0.001) with incubation time. The element analysis of eggshells with different levels of pink pigment showed that the potassium content of the eggshells for all pigment levels decreased significantly during incubation. Conclusion. In summary, pigment intensity and the region of the eggshell influenced the percent transmission of light of eggshell. Differences in the spectral characteristics of different eggshells may influence the effects of photostimulation during the incubation of eggs. All of these results will be applicable for perfecting the design of light intensity for lighted incubation to improve productivity. PMID:27019785

  14. Small optical inter-satellite communication system for small and micro satellites

    NASA Astrophysics Data System (ADS)

    Iwamoto, Kyohei; Nakao, Takashi; Ito, Taiji; Sano, Takeshi; Ishii, Tamotsu; Shibata, Keiichi; Ueno, Mitsuhiro; Ohta, Shinji; Komatsu, Hiromitsu; Araki, Tomohiro; Kobayashi, Yuta; Sawada, Hirotaka

    2017-02-01

    Small optical inter-satellite communication system to be installed into small and micro satellites flying on LEO are designed and experimentally verified of its fundamental functions. Small, light weighted, power efficient as well as usable data transmission rate optical inter-satellite communication system is one of promising approach to provide realtime data handling and operation capabilities for micro and small satellite constellations which have limited conditions of payload. Proposed system is designed to connect satellites with 4500 (km) long maximum to be able to talk with ground station continuously by relaying LEO satellites even when they are in their own maneuvers. Connecting satellites with 4500 (km) long with keeping steady data rate, accurate pointing and tracking method will be one of a crucial issue. In this paper, we propose a precious pointing and tracking method and system with a miniature optics and experimentally verified almost 10 (μrad) of pointing accuracy with more than 500 (mrad) of angular coverage.

  15. Role of recoverin in rod photoreceptor light adaptation.

    PubMed

    Morshedian, Ala; Woodruff, Michael L; Fain, Gordon L

    2018-04-15

    Recoverin is a small molecular-weight, calcium-binding protein in rod outer segments that can modulate the rate of rhodopsin phosphorylation. We describe two additional and perhaps more important functions during photoreceptor light adaptation. Recoverin influences the rate of change of adaptation. In wild-type rods, sensitivity and response integration time adapt with similar time constants of 150-200 ms. In Rv-/- rods lacking recoverin, sensitivity declines faster and integration time is already shorter and not significantly altered. During steady light exposure, rod circulating current slowly increases during a time course of tens of seconds, gradually extending the operating range of the rod. In Rv-/- rods, this mechanism is deleted, steady-state currents are already larger and rods saturate at brighter intensities. We propose that recoverin modulates spontaneous and light-activated phophodiesterase-6, the phototransduction effector enzyme, to increase sensitivity in dim light but improve responsiveness to change in brighter illumination. Recoverin is a small molecular-weight, calcium-binding protein in rod outer segments that binds to G-protein receptor kinase 1 and can alter the rate of rhodopsin phosphorylation. A change in phosphorylation should change the lifetime of light-activated rhodopsin and the gain of phototransduction, but deletion of recoverin has little effect on the sensitivity of rods either in the dark or in dim-to-moderate background light. We describe two additional functions perhaps of greater physiological significance. (i) When the ambient intensity increases, sensitivity and integration time decrease in wild-type (WT) rods with similar time constants of 150-200 ms. Recoverin is part of the mechanism controlling this process because, in Rv-/- rods lacking recoverin, sensitivity declines more rapidly and integration time is already shorter and not further altered. (ii) During steady light exposure, WT rod circulating current slowly increases during a time course of tens of seconds, gradually extending the operating range of the rod. In Rv-/- rods, this mechanism is also deleted, steady-state currents are already larger and rods saturate at brighter intensities. We argue that neither (i) nor (ii) can be caused by modulation of rhodopsin phosphorylation but may instead be produced by direct modulation of phophodiesterase-6 (PDE6), the phototransduction effector enzyme. We propose that recoverin in dark-adapted rods keeps the integration time long and the spontaneous PDE6 rate relatively high to improve sensitivity. In background light, the integration time is decreased to facilitate detection of change and motion and the spontaneous PDE6 rate decreases to augment the rod working range. © 2018 The Authors. The Journal of Physiology © 2018 The Physiological Society.

  16. Practical technique to quantify small, dense low-density lipoprotein cholesterol using dynamic light scattering

    NASA Astrophysics Data System (ADS)

    Trirongjitmoah, Suchin; Iinaga, Kazuya; Sakurai, Toshihiro; Chiba, Hitoshi; Sriyudthsak, Mana; Shimizu, Koichi

    2016-04-01

    Quantification of small, dense low-density lipoprotein (sdLDL) cholesterol is clinically significant. We propose a practical technique to estimate the amount of sdLDL cholesterol using dynamic light scattering (DLS). An analytical solution in a closed form has newly been obtained to estimate the weight fraction of one species of scatterers in the DLS measurement of two species of scatterers. Using this solution, we can quantify the sdLDL cholesterol amount from the amounts of the low-density lipoprotein cholesterol and the high-density lipoprotein (HDL) cholesterol, which are commonly obtained through clinical tests. The accuracy of the proposed technique was confirmed experimentally using latex spheres with known size distributions. The applicability of the proposed technique was examined using samples of human blood serum. The possibility of estimating the sdLDL amount using the HDL data was demonstrated. These results suggest that the quantitative estimation of sdLDL amounts using DLS is feasible for point-of-care testing in clinical practice.

  17. 40 CFR 86.087-2 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... vehicle weight equal to or less than 3,750 lbs (LDDT1s) together in the particulate averaging program... light-duty truck production for those engine families with a loaded vehicle weight equal to or less than... light-duty truck particulate standard for diesel light-duty trucks with a loaded vehicle weight equal to...

  18. Using image analysis to predict the weight of Alaskan salmon of different species.

    PubMed

    Balaban, Murat O; Unal Sengör, Gülgün F; Gil Soriano, Mario; Guillén Ruiz, Elena

    2010-04-01

    After harvesting, salmon is sorted by species, size, and quality. This is generally manually done by operators. Automation would bring repeatability, objectivity, and record-keeping capabilities to these tasks. Machine vision (MV) and image analysis have been used in sorting many agricultural products. Four salmon species were tested: pink (Oncorhynchus gorbuscha), red (Oncorhynchus nerka), silver (Oncorhynchus kisutch), and chum (Oncorhynchus keta). A total of 60 whole fish from each species were first weighed, then placed in a light box to take their picture. Weight compared with view area as well as length and width correlations were developed. In addition the effect of "hump" development (see text) of pink salmon on this correlation was investigated. It was possible to predict the weight of a salmon by view area, regardless of species, and regardless of the development of a hump for pinks. Within pink salmon there was a small but insignificant difference between predictive equations for the weight of "regular" fish and "humpy" fish. Machine vision can accurately predict the weight of whole salmon for sorting.

  19. Weighted optimization of irradiance for photodynamic therapy of port wine stains

    NASA Astrophysics Data System (ADS)

    He, Linhuan; Zhou, Ya; Hu, Xiaoming

    2016-10-01

    Planning of irradiance distribution (PID) is one of the foremost factors for on-demand treatment of port wine stains (PWS) with photodynamic therapy (PDT). A weighted optimization method for PID was proposed according to the grading of PWS with a three dimensional digital illumination instrument. Firstly, the point clouds of lesions were filtered to remove the error or redundant points, the triangulation was carried out and the lesion was divided into small triangular patches. Secondly, the parameters such as area, normal vector and orthocenter for optimization of each triangular patch were calculated, and the weighted coefficients were determined by the erythema indexes and areas of patches. Then, the optimization initial point was calculated based on the normal vectors and orthocenters to optimize the light direction. In the end, the irradiation can be optimized according to cosine values of irradiance angles and weighted coefficients. Comparing the irradiance distribution before and after optimization, the proposed weighted optimization method can make the irradiance distribution match better with the characteristics of lesions, and has the potential to improve the therapeutic efficacy.

  20. Head or tail: the orientation of the small bowel capsule endoscope movement in the small bowel.

    PubMed

    Kopylov, Uri; Papageorgiou, Neofytos P; Nadler, Moshe; Eliakim, Rami; Ben-Horin, Shomron

    2012-03-01

    The diagnostic accuracy of capsule endoscopy has been suggested to be influenced by the direction of the passage in the intestine. It is currently unknown if a head-first or a tail-first orientation are equally common during the descent through the small bowel. The aim of the study was to identify the orientation of the capsule along the migration through the small bowel. Thirty capsule endoscopies were reviewed by an experienced observer. The direction of the passage through the pylorus and the ileoceccal valve was recorded for all the examinations. In addition, detailed review of the passage of the capsule in different segments of the small bowel was undertaken for all the capsules. The capsule was significantly more likely to pass the pylorus head-first compared to tail-first (25 and 5 out of 30, respectively, OR 5, 95% CI 65-94%, P < 0.001). In 28/30 studies, the capsule exited the ileoceccal valve head-first (OR-14, 95% CI 77-99%, P < 0.001). In an immersion experiment, uneven distribution of weight of the capsule body was demonstrated with the head part (camera tip) being lighter than the tail part. The capsule endoscope usually passes through the pylorus and subsequent segments of the small bowel head-first. This observation suggests that the intestinal peristaltic physiology drives symmetrical bodies with their light part first. The principle of intestinal orientation by weight distribution may bear implications for capsules' design in the future.

  1. Laser desorption ionization mass spectrometry: Recent progress in matrix-free and label-assisted techniques.

    PubMed

    Mandal, Arundhoti; Singha, Monisha; Addy, Partha Sarathi; Basak, Amit

    2017-10-13

    The MALDI-based mass spectrometry, over the last three decades, has become an important analytical tool. It is a gentle ionization technique, usually applicable to detect and characterize analytes with high molecular weights like proteins and other macromolecules. The earlier difficulty of detection of analytes with low molecular weights like small organic molecules and metal ion complexes with this technique arose due to the cluster of peaks in the low molecular weight region generated from the matrix. To detect such molecules and metal ion complexes, a four-prong strategy has been developed. These include use of alternate matrix materials, employment of new surface materials that require no matrix, use of metabolites that directly absorb the laser light, and the laser-absorbing label-assisted LDI-MS (popularly known as LALDI-MS). This review will highlight the developments with all these strategies with a special emphasis on LALDI-MS. © 2017 Wiley Periodicals, Inc.

  2. Light-weight plastination.

    PubMed

    Steinke, Hanno; Rabi, Suganthy; Saito, Toshiyuki; Sawutti, Alimjan; Miyaki, Takayoshi; Itoh, Masahiro; Spanel-Borowski, Katharina

    2008-11-20

    Plastination is an excellent technique which helps to keep the anatomical specimens in a dry, odourless state. Since the invention of plastination technique by von Hagens, research has been done to improve the quality of plastinated specimens. In this paper, we have described a method of producing light-weight plastinated specimens using xylene along with silicone and in the final step, substitute xylene with air. The finished plastinated specimens were light-weight, dry, odourless and robust. This method requires less use of resin thus making the plastination technique more cost-effective. The light-weight specimens are easy to carry and can easily be used for teaching.

  3. 60-GHz integrated-circuit high data rate quadriphase shift keying exciter and modulator

    NASA Technical Reports Server (NTRS)

    Grote, A.; Chang, K.

    1984-01-01

    An integrated-circuit quadriphase shift keying (QPSK) exciter and modulator have demonstrated excellent performance directly modulating a carrier frequency of 60 GHz with an output phase error of less than 3 degrees and maximum amplitude error of 0.5 dB. The circuit consists of a 60-GHz Gunn VCO phase-locked to a low-frequency reference source, a 4th subharmonic mixer, and a QPSK modlator packaged into a small volume of 1.8 x 2.5 x 0.35 in. The use of microstrip has the advantages of small size, light-weight, and low-cost fabrication. The unit has the potential for multigigabit data rate applications.

  4. Large Scale Reduction of Graphite Oxide Project

    NASA Technical Reports Server (NTRS)

    Calle, Carlos; Mackey, Paul; Falker, John; Zeitlin, Nancy

    2015-01-01

    This project seeks to develop an optical method to reduce graphite oxide into graphene efficiently and in larger formats than currently available. Current reduction methods are expensive, time-consuming or restricted to small, limited formats. Graphene has potential uses in ultracapacitors, energy storage, solar cells, flexible and light-weight circuits, touch screens, and chemical sensors. In addition, graphite oxide is a sustainable material that can be produced from any form of carbon, making this method environmentally friendly and adaptable for in-situ reduction.

  5. Defense Small Business Innovation Research Program (SBIR). Volume 3. Air Force Abstracts of Phase 1 Awards from FY 1988 SBIR Solicitation

    DTIC Science & Technology

    1989-05-01

    THE TARGET DOPPLER FREQUENCIES. ADAPTIVE SENSORS INC 216 PICO BLVD - STE 8 SANTA MONICA, CA 90405 CONTRACT NUMBER: JOHN S BAILEY TITLE: SPATIALLY...APPLIED RESEARCH ASSOCS INC 4300 SAN MATEO BLVD NE - STE A220 ALBUQUERQUE, NM 87110 CONTRACT NUMBER: FRANK A MAESTAS TITLE: PARAMETRIC ANALYSIS OF EXPLOSIVE...VERIFIED THROUGH SUBSCALE FABRICATION AND TEST. AV DYNAMICS INC 825 MYRTLE AVE MONROVIA, CA 91016 CONTRACT NUMBER: DR P B S LISSAMAN TITLE: LIGHT WEIGHT

  6. Synthesis of freeform refractive surfaces forming various radiation patterns using interpolation

    NASA Astrophysics Data System (ADS)

    Voznesenskaya, Anna; Mazur, Iana; Krizskiy, Pavel

    2017-09-01

    Optical freeform surfaces are very popular today in such fields as lighting systems, sensors, photovoltaic concentrators, and others. The application of such surfaces allows to obtain systems with a new quality with a reduced number of optical components to ensure high consumer characteristics: small size, weight, high optical transmittance. This article presents the methods of synthesis of refractive surface for a given source and the radiation pattern of various shapes using a computer simulation cubic spline interpolation.

  7. Imaging spectrometer using a liquid crystal tunable filter

    NASA Astrophysics Data System (ADS)

    Chrien, Thomas G.; Chovit, Christopher; Miller, Peter J.

    1993-09-01

    A demonstration imaging spectrometer using a liquid crystal tunable filter (LCTF) was built and tested on a hot air balloon platform. The LCTF is a tunable polarization interference or Lyot filter. The LCTF enables a small, light weight, low power, band sequential imaging spectrometer design. An overview of the prototype system is given along with a description of balloon experiment results. System model performance predictions are given for a future LCTF based imaging spectrometer design. System design considerations of LCTF imaging spectrometers are discussed.

  8. Coronary heart disease risk factors in men with light and dark skin in Puerto Rico.

    PubMed Central

    Costas, R; Garcia-Palmieri, M R; Sorlie, P; Hertzmark, E

    1981-01-01

    The association of skin color with coronary heart disease risk factors was studied in 4,000 urban Puerto Rican men. Skin color on the inner upper arm was classified according to the von Luschan color tiles. Using this grading, men were separated into two groups of light or dark skin color. The dark group had a lower socioeconomic status (SES) based on income, education, and occupation. Dark men had slightly higher mean systolic blood pressures (SBP) and lower mean serum cholesterol levels than the light, but the relative weights and cigarette smoking habits of both groups were similar. After controlling for the differences in SES, skin color showed a small but statistically significant association with SBP. Whether this association with skin color represents genetic or environmental influences on SBP could not be determined from this study. PMID:7235099

  9. APBF-DEC NOx Adsorber/DPF Project: SUV / Pick-up Truck Platform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Webb, C; Weber, P; Thornton,M

    2003-08-24

    The objective of this project is to determine the influence of diesel fuel composition on the ability of NOX adsorber catalyst (NAC) technology, in conjunction with diesel particle filters (DPFs), to achieve stringent emissions levels with a minimal fuel economy impact. The test bed for this project was intended to be a light-duty sport utility vehicle (SUV) with a goal of achieving light-duty Tier 2-Bin 5 tail pipe emission levels (0.07 g/mi. NOX and 0.01 g/mi. PM). However, with the current US market share of light-duty diesel applications being so low, no US 2002 model year (MY) light-duty truck (LDT)more » or SUV platforms equipped with a diesel engine and having a gross vehicle weight rating (GVWR) less than 8500 lb exist. While the current level of diesel engine use is relatively small in the light-duty class, there exists considerable potential for the diesel engine to gain a much larger market share in the future as manufacturers of heavy light-duty trucks (HLDTs) attempt to offset the negative impact on cooperate average fuel economy (CAFE) that the recent rise in market share of the SUVs and LDTs has caused. The US EPA Tier 2 emission standards also contain regulation to prevent the migration of heavy light-duty trucks and SUV's to the medium duty class. This preventive measure requires that all medium duty trucks, SUV's and vans in the 8,500 to 10,000 lb GVWR range being used as passenger vehicles, meet light-duty Tier 2 standards. In meeting the Tier 2 emission standards, the HLDTs and medium-duty passenger vehicles (MDPVs) will face the greatest technological challenges. Because the MDPV is the closest weight class and application relative to the potential upcoming HLDTs and SUV's, a weight class compromise was made in this program to allow the examination of using a diesel engine with a NAC-DPF system on a 2002 production vehicle. The test bed for this project is a 2500 series Chevrolet Silverado equipped with a 6.6L Duramax diesel engine certified to 2002 MY Federal heavy-duty and 2002 MY California medium-duty emission standards. The stock vehicle included cooled air charge (CAC), turbocharger (TC), direct fuel injection (DFI), oxidation catalyst (OC), and exhaust gas recirculation (EGR)« less

  10. Using light transmission to watch hydrogen diffuse

    PubMed Central

    Pálsson, Gunnar K.; Bliersbach, Andreas; Wolff, Max; Zamani, Atieh; Hjörvarsson, Björgvin

    2012-01-01

    Because of its light weight and small size, hydrogen exhibits one of the fastest diffusion rates in solid materials, comparable to the diffusion rate of liquid water molecules at room temperature. The diffusion rate is determined by an intricate combination of quantum effects and dynamic interplay with the displacement of host atoms that is still only partially understood. Here we present direct observations of the spatial and temporal changes in the diffusion-induced concentration profiles in a vanadium single crystal and we show that the results represent the experimental counterpart of the full time and spatial solution of Fick's diffusion equation. We validate the approach by determining the diffusion rate of hydrogen in a single crystal vanadium (001) film, with net diffusion in the [110] direction. PMID:22692535

  11. Using light transmission to watch hydrogen diffuse

    NASA Astrophysics Data System (ADS)

    Pálsson, Gunnar K.; Bliersbach, Andreas; Wolff, Max; Zamani, Atieh; Hjörvarsson, Björgvin

    2012-06-01

    Because of its light weight and small size, hydrogen exhibits one of the fastest diffusion rates in solid materials, comparable to the diffusion rate of liquid water molecules at room temperature. The diffusion rate is determined by an intricate combination of quantum effects and dynamic interplay with the displacement of host atoms that is still only partially understood. Here we present direct observations of the spatial and temporal changes in the diffusion-induced concentration profiles in a vanadium single crystal and we show that the results represent the experimental counterpart of the full time and spatial solution of Fick's diffusion equation. We validate the approach by determining the diffusion rate of hydrogen in a single crystal vanadium (001) film, with net diffusion in the [110] direction.

  12. Succession of the turkey gastrointestinal bacterial microbiome related to weight gain.

    PubMed

    Danzeisen, Jessica L; Calvert, Alamanda J; Noll, Sally L; McComb, Brian; Sherwood, Julie S; Logue, Catherine M; Johnson, Timothy J

    2013-12-23

    Because of concerns related to the use of antibiotics in animal agriculture, antibiotic-free alternatives are greatly needed to prevent disease and promote animal growth. One of the current challenges facing commercial turkey production in Minnesota is difficulty obtaining flock average weights typical of the industry standard, and this condition has been coined "Light Turkey Syndrome" or LTS. This condition has been identified in Minnesota turkey flocks for at least five years, and it has been observed that average flock body weights never approach their genetic potential. However, a single causative agent responsible for these weight reductions has not been identified despite numerous efforts to do so. The purpose of this study was to identify the bacterial community composition within the small intestines of heavy and light turkey flocks using 16S rRNA sequencing, and to identify possible correlations between microbiome and average flock weight. This study also sought to define the temporal succession of bacteria occurring in the turkey ileum. Based upon 2.7 million sequences across nine different turkey flocks, dominant operational taxonomic units (OTUs) were identified and compared between the flocks studied. OTUs that were associated with heavier weight flocks included those with similarity to Candidatus division Arthromitus and Clostridium bartlettii, while these flocks had decreased counts of several Lactobacillus species compared to lighter weight flocks. The core bacterial microbiome succession in commercial turkeys was also defined. Several defining markers of microbiome succession were identified, including the presence or abundance of Candidatus division Arthromitus, Lactobacillus aviarius, Lactobacillus ingluviei, Lactobacillus salivarius, and Clostridium bartlettii. Overall, the succession of the ileum bacterial microbiome in commercial turkeys proceeds in a predictable manner. Efforts to prevent disease and promote growth in the absence of antibiotics could involve target dominant bacteria identified in the turkey ileum that are associated with increased weight gain.

  13. Succession of the turkey gastrointestinal bacterial microbiome related to weight gain

    PubMed Central

    Danzeisen, Jessica L.; Calvert, Alamanda J.; Noll, Sally L.; McComb, Brian; Sherwood, Julie S.; Logue, Catherine M.

    2013-01-01

    Because of concerns related to the use of antibiotics in animal agriculture, antibiotic-free alternatives are greatly needed to prevent disease and promote animal growth. One of the current challenges facing commercial turkey production in Minnesota is difficulty obtaining flock average weights typical of the industry standard, and this condition has been coined “Light Turkey Syndrome” or LTS. This condition has been identified in Minnesota turkey flocks for at least five years, and it has been observed that average flock body weights never approach their genetic potential. However, a single causative agent responsible for these weight reductions has not been identified despite numerous efforts to do so. The purpose of this study was to identify the bacterial community composition within the small intestines of heavy and light turkey flocks using 16S rRNA sequencing, and to identify possible correlations between microbiome and average flock weight. This study also sought to define the temporal succession of bacteria occurring in the turkey ileum. Based upon 2.7 million sequences across nine different turkey flocks, dominant operational taxonomic units (OTUs) were identified and compared between the flocks studied. OTUs that were associated with heavier weight flocks included those with similarity to Candidatus division Arthromitus and Clostridium bartlettii, while these flocks had decreased counts of several Lactobacillus species compared to lighter weight flocks. The core bacterial microbiome succession in commercial turkeys was also defined. Several defining markers of microbiome succession were identified, including the presence or abundance of Candidatus division Arthromitus, Lactobacillus aviarius, Lactobacillus ingluviei, Lactobacillus salivarius, and Clostridium bartlettii. Overall, the succession of the ileum bacterial microbiome in commercial turkeys proceeds in a predictable manner. Efforts to prevent disease and promote growth in the absence of antibiotics could involve target dominant bacteria identified in the turkey ileum that are associated with increased weight gain. PMID:24432198

  14. The ac stark shift and space-borne rubidium atomic clocks

    NASA Astrophysics Data System (ADS)

    Formichella, V.; Camparo, J.; Sesia, I.; Signorile, G.; Galleani, L.; Huang, M.; Tavella, P.

    2016-11-01

    Due to its small size, low weight, and low power consumption, the Rb atomic frequency standard (RAFS) is routinely the first choice for atomic timekeeping in space. Consequently, though the device has very good frequency stability (rivaling passive hydrogen masers), there is interest in uncovering the fundamental processes limiting its long-term performance, with the goal of improving the device for future space systems and missions. The ac Stark shift (i.e., light shift) is one of the more likely processes limiting the RAFS' long-term timekeeping ability, yet its manifestation in the RAFS remains poorly understood. In part, this comes from the fact that light-shift induced frequency fluctuations must be quantified in terms of the RAFS' light-shift coefficient and the output variations in the RAFS' rf-discharge lamp, which is a nonlinear inductively-couple plasma (ICP). Here, we analyze the light-shift effect for a family of 10 on-orbit Block-IIR GPS RAFS, examining decade-long records of their on-orbit frequency and rf-discharge lamp fluctuations. We find that the ICP's light intensity variations can take several forms: deterministic aging, jumps, ramps, and non-stationary noise, each of which affects the RAFS' frequency via the light shift. Correlating these light intensity changes with RAFS frequency changes, we estimate the light-shift coefficient, κLS, for the family of RAFS: κLS = -(1.9 ± 0.3) × 10-12/%. The 16% family-wide variation in κLS indicates that while each RAFS may have its own individual κLS, the variance of κLS among similarly designed RAFS can be relatively small. Combining κLS with our estimate of the ICP light intensity's non-stationary noise, we find evidence that random-walk frequency noise in high-quality space-borne RAFS is strongly influenced by the RAFS' rf-discharge lamp via the light shift effect.

  15. The effect of 580 nm-based-LED mixed light on growth, adipose deposition, skeletal development, and body temperature of chickens.

    PubMed

    Yang, Yefeng; Zhen, Chenghuang; Yang, Bo; Yu, Yonghua; Pan, Jinming

    2018-06-01

    Though previous study indicated that the 580 nm-yellow-LED-light showed an stimulating effect on growth of chickens, the low luminous efficiency of the yellow LED light cannot reflect the advantage of energy saving. In present study, the cool white LED chips and yellow LED chips have been combined to fabricate the white × yellow mixed LED light, with an enhanced luminous efficiency. A total 300 newly hatched chickens were reared under various mixed LED light. The results indicated that the white × yellow mixed LED light had "double-edged sword" effects on bird's body weight, bone development, adipose deposition, and body temperature, depending on variations in ratios of yellow component. Low yellow ratio of mixed LED light (Low group) inhibited body weight, whereas medium and high yellow ratio of mixed LED light (Medium and High groups) promoted body weight, compared with white LED light (White group). A progressive change in yellow component gave rise to consistent changes in body weight over the entire experiment. Moreover, a positive relationship was observed between yellow component and feed conversion ratio. High group-treated birds had greater relative abdominal adipose weight than Medium group-treated birds (P = 0.048), whereas Medium group-treated birds had greater relative abdominal adipose weight than Low group-treated birds (P = 0.044). We found that mixed light improved body weight by enhancing skeletal development (R 2  = 0.5023, P = 0.0001) and adipose deposition (R 2  = 0.6012, P = 0.0001). Birds in the Medium, High and Yellow groups attained significantly higher surface temperatures compared with the White group (P = 0.010). The results suggest that the application of the mixed light with high level of yellow component can be used successfully to improve growth and productive performance in broilers. Copyright © 2018. Published by Elsevier B.V.

  16. Study of data collection platform concepts: Data collection system user requirements

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The overall purpose of the survey was to provide real world data on user requirements. The intent was to assess data collection system user requirements by questioning actual potential users rather than speculating on requirements. The end results of the survey are baseline requirements models for both a data collection platform and a data collection system. These models were derived from the survey results. The real value of these models lies in the fact that they are based on actual user requirements as delineated in the survey questionnaires. Some users desire data collection platforms of small size and light weight. These sizes and weights are beyond the present state of the art. Also, the survey provided a wealth of information on the nature and constituency of the data collection user community as well as information on user applications for data collection systems. Finally, the data sheds light on the generalized platform concept. That is, the diversity of user requirements shown in the data indicates the difficulty that can be anticipated in attempting to implement such a concept.

  17. Development of a light-weight, wind-turbine-rotor-based data acquisition system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berg, D.E.; Rumsey, M.; Robertson, P.

    1997-12-01

    Wind-energy researchers at Sandia National Laboratories (SNL) and the National Renewable Energy Laboratory (NREL) are developing a new, light-weight, modular system capable of acquiring long-term, continuous time-series data from current-generation small or large, dynamic wind-turbine rotors. Meetings with wind-turbine research personnel at NREL and SNL resulted in a list of the major requirements that the system must meet. Initial attempts to locate a commercial system that could meet all of these requirements were not successful, but some commercially available data acquisition and radio/modem subsystems that met many of the requirements were identified. A time synchronization subsystem and a programmable logicmore » device subsystem to integrate the functions of the data acquisition, the radio/modem, and the time synchronization subsystems and to communicate with the user have been developed at SNL. This paper presents the data system requirements, describes the four major subsystems comprising the system, summarizes the current status of the system, and presents the current plans for near-term development of hardware and software.« less

  18. Infrared hyperspectral imaging sensor for gas detection

    NASA Astrophysics Data System (ADS)

    Hinnrichs, Michele

    2000-11-01

    A small light weight man portable imaging spectrometer has many applications; gas leak detection, flare analysis, threat warning, chemical agent detection, just to name a few. With support from the US Air Force and Navy, Pacific Advanced Technology has developed a small man portable hyperspectral imaging sensor with an embedded DSP processor for real time processing that is capable of remotely imaging various targets such as gas plums, flames and camouflaged targets. Based upon their spectral signature the species and concentration of gases can be determined. This system has been field tested at numerous places including White Mountain, CA, Edwards AFB, and Vandenberg AFB. Recently evaluation of the system for gas detection has been performed. This paper presents these results. The system uses a conventional infrared camera fitted with a diffractive optic that images as well as disperses the incident radiation to form spectral images that are collected in band sequential mode. Because the diffractive optic performs both imaging and spectral filtering, the lens system consists of only a single element that is small, light weight and robust, thus allowing man portability. The number of spectral bands are programmable such that only those bands of interest need to be collected. The system is entirely passive, therefore, easily used in a covert operation. Currently Pacific Advanced Technology is working on the next generation of this camera system that will have both an embedded processor as well as an embedded digital signal processor in a small hand held camera configuration. This will allow the implementation of signal and image processing algorithms for gas detection and identification in real time. This paper presents field test data on gas detection and identification as well as discuss the signal and image processing used to enhance the gas visibility. Flow rates as low as 0.01 cubic feet per minute have been imaged with this system.

  19. Effect of egg weight on composition, embryonic growth, and expression of amino acid transporter genes in yolk sac membranes and small intestines of the domestic pigeon (Columba livia).

    PubMed

    Chen, M X; Li, X G; Yan, H C; Wang, X Q; Gao, C Q

    2016-06-01

    The objective of this study was to investigate the effect of egg weight on the composition of the egg, the growth of the embryo, and the expression of amino acid transporter genes in the yolk sac membranes and small intestines of the domestic pigeon (Columba livia). A total of 240 fertilized eggs were collected and divided into two groups based on the weight of the eggs, light (LE) and heavy (HE). The composition of 20 eggs from each group was measured, and the remaining eggs were weighed and placed in an incubator. On embryonic days (E) 9, 11, 13, and 15 and day of hatch (DOH), 15 embryos/hatchlings from each group were measured for embryonic growth, and samples were collected. The HE had heavier yolk and albumen weights than the LE (P < 0.01). Compared with the LE, the HE had heavier yolk-free embryonic body and yolk sac weights from E13 to DOH (P < 0.05). Additionally, the HE had larger yolk sac membrane weights from E13 to E15 (P < 0.05) and had more residual yolk sac content on DOH than those of the LE (P < 0.01). The yolk absorption was greater for the HE than for the LE from E11 to E13 (P < 0.05). Furthermore, the abundance of CAT2 and PepT1 mRNA in the yolk sac membranes was greater in the HE than in the LE on E13 (P < 0.05). Compared with the LE, the gene expression of EAAT2 in the intestine on E13 was greater in the HE, whereas the expression of EAAT3 was lower in the HE (P < 0.05). Taken together, our results suggest that egg weight influenced the composition of the eggs, embryonic development, and expression of amino acid transporter genes in the yolk sac membranes and small intestines of pigeon embryos. © 2016 Poultry Science Association Inc.

  20. Effects of stocking density, light and perches on broiler growth.

    PubMed

    Velo, Ramón; Ceular, Angel

    2017-02-01

    The aim of this study was to determine the effect of stocking density, light intensity and light color on broiler growth. The experiment consisted of four 35-day phases during each of which 320 chickens were surveyed. The research was performed at stocking densities of four and six birds/m 2 . Illuminances of 15 and 30 lx were obtained through commercial lamps with 4000 K and 6000 K color temperatures. Lighting was used 17 h a day, between 06.00 and 23.00 hours (17 L:7 D). The results showed a decrease in body, carcass, breast and thighs weight (P < 0.05) with the increase in stocking density. Body weight decreased by 10.5% and carcass weight decreased by 9.4% at six birds/m 2 stocking density. Contrastingly, no differences were found for the tested light colors. Increasing illuminance from 15 to 30 lx caused a 1.9% decrease in body weight. The analysis of the effect of perches revealed that using perches significantly increased body (2.5%) and breast weight (11.8%). The interactions between light intensity or color and stocking density and between light intensity and light color were analyzed. © 2016 Japanese Society of Animal Science.

  1. Optical cloud detection from a disposable airborne sensor

    NASA Astrophysics Data System (ADS)

    Nicoll, Keri; Harrison, R. Giles; Brus, David

    2016-04-01

    In-situ measurement of cloud droplet microphysical properties is most commonly made from manned aircraft platforms due to the size and weight of the instrumentation, which is both costly and typically limited to sampling only a few clouds. This work describes the development of a small, lightweight (<200g), disposable, optical cloud sensor which is designed for use on routine radiosonde balloon flights and also small unmanned aerial vehicle (UAV) platforms. The sensor employs the backscatter principle, using an ultra-bright LED as the illumination source, with a photodiode detector. Scattering of the LED light by cloud droplets generates a small optical signal which is separated from background light fluctuations using a lock-in technique. The signal to noise obtained permits cloud detection using the scattered LED light, even in daytime. During recent field tests in Pallas, Finland, the retrieved optical sensor signal has been compared with the DMT Cloud and Aerosol Spectrometer (CAS) which measures cloud droplets in the size range from 0.5 to 50 microns. Both sensors were installed at the hill top observatory of Sammaltunturi during a field campaign in October and November 2015, which experienced long periods of immersion inside cloud. Preliminary analysis shows very good agreement between the CAPS and the disposable cloud sensor for cloud droplets >5micron effective diameter. Such data and calibration of the sensor will be discussed here, as will simultaneous balloon launches of the optical cloud sensor through the same cloud layers.

  2. A novel contrast agent with rare earth-doped up-conversion luminescence and Gd-DTPA magnetic resonance properties

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu Qing; Wei Daixu; Cheng Jiejun

    2012-08-15

    The magnetic-luminescent multifunctional nanoparticles based on Gd-DTPA and NaYF{sub 4}:Yb, Er were successfully synthesized by the conjugation of activated DTPA and silica-coated/surface-aminolated NaYF{sub 4}:Yb, Er nanoparticles through EDC/NHS coupling chemistry. The as-prepared products were characterized by powder X-ray diffraction, transmission electron microscopy, dynamic light scattering, energy dispersive X-ray analysis, and fourier transform infrared spectrometry. The room-temperature upconversion luminescent spectra and T{sub 1}-weighted maps of the obtained nanoparticles were carried out by 980 nm NIR light excitation and a 3T MR imaging scanner, respectively. The results indicated that the as-synthesized multifunctional nanoparticles with small size, highly solubility in water, and bothmore » high MR relaxivities and upconversion luminescence may have potential usage for MR imaging in future. - Graphical abstract: We have synthesized magnetic-luminescent multifunctional nanoparticles based on Gd-DTPA and NaYF4:Yb, Er by the conjugation of activated DTPA and silica-coated/surface-aminolated NaYF4:Yb, Er nanoparticles through EDC/NHS coupling chemistry. Highlights: Black-Right-Pointing-Pointer A novel magnetic-luminescent multifunctional nanoparticles are synthesized. Black-Right-Pointing-Pointer The nanoparticles are highly efficient for luminescence and T{sub 1}-weighted MR imaging. Black-Right-Pointing-Pointer The nanoparticles are small in size and highly solubility in water. Black-Right-Pointing-Pointer The nanoparticles hold great potential usage for future biomedical engineering.« less

  3. Effects of light sources and intensity on broilers grown to heavy weights: Hematophysiological and biochemical assessment.

    USDA-ARS?s Scientific Manuscript database

    Most governments around the world including the USA have passed measures to phase out incandescent light bulbs in favor of more energy-efficient lighting alternatives. Research is limited on blood physiological variables of broilers grown to heavy weights (> 3 kg) under these new light sources to en...

  4. Synthesis and Characterization of Graft Copolymers Poly(isoprene-g-styrene) of High Molecular Weight by a Combination of Anionic Polymerization and Emulsion Polymerization

    DOE PAGES

    Wang, Wenwen; Wang, Weiyu; Li, Hui; ...

    2015-01-14

    In this study, high molecular weight “comb-shaped” graft copolymers, poly(isoprene-g-styrene), with polyisoprene as the backbone and polystyrene as side chains, were synthesized via free radical emulsion polymerization by copolymerization of isoprene with a polystyrene macromonomer synthesized using anionic polymerization. A small amount of toluene was used in order to successfully disperse the macromonomer. Both a redox and thermal initiation system were used in the emulsion polymerization, and the latex particle size and distribution were investigated by dynamic light scattering. The structural characteristics of the macromonomer and comb graft copolymers were investigated through use of size exclusion chromatography, spectroscopy, microscopy, thermalmore » analysis, and rheology. While the macromonomer was successfully copolymerized to obtain the desired multigraft copolymers, small amounts of unreacted macromonomer remained in the products, reflecting its reduced reactivity due to steric effects. Nevertheless, the multigraft copolymers obtained were very high in molecular weight (5–12 × 10 5 g/mol) and up to 10 branches per chain, on average, could be incorporated. A material incorporating 29 wt% polystyrene exhibits a disordered microphase separated morphology and elastomeric properties. As a result, these materials show promise as new, highly tunable, and potentially low cost thermoplastic elastomers.« less

  5. Study on light weight design of truss structures of spacecrafts

    NASA Astrophysics Data System (ADS)

    Zeng, Fuming; Yang, Jianzhong; Wang, Jian

    2015-08-01

    Truss structure is usually adopted as the main structure form for spacecrafts due to its high efficiency in supporting concentrated loads. Light-weight design is now becoming the primary concern during conceptual design of spacecrafts. Implementation of light-weight design on truss structure always goes through three processes: topology optimization, size optimization and composites optimization. During each optimization process, appropriate algorithm such as the traditional optimality criterion method, mathematical programming method and the intelligent algorithms which simulate the growth and evolution processes in nature will be selected. According to the practical processes and algorithms, combined with engineering practice and commercial software, summary is made for the implementation of light-weight design on truss structure for spacecrafts.

  6. Patient-specific dose estimation for pediatric abdomen-pelvis CT

    NASA Astrophysics Data System (ADS)

    Li, Xiang; Samei, Ehsan; Segars, W. Paul; Sturgeon, Gregory M.; Colsher, James G.; Frush, Donald P.

    2009-02-01

    The purpose of this study is to develop a method for estimating patient-specific dose from abdomen-pelvis CT examinations and to investigate dose variation across patients in the same weight group. Our study consisted of seven pediatric patients in the same weight/protocol group, for whom full-body computer models were previously created based on the patients' CT data obtained for clinical indications. Organ and effective dose of these patients from an abdomen-pelvis scan protocol (LightSpeed VCT scanner, 120-kVp, 85-90 mA, 0.4-s gantry rotation period, 1.375-pitch, 40-mm beam collimation, and small body scan field-of-view) was calculated using a Monte Carlo program previously developed and validated for the same CT system. The seven patients had effective dose of 2.4-2.8 mSv, corresponding to normalized effective dose of 6.6-8.3 mSv/100mAs (coefficient of variation: 7.6%). Dose variations across the patients were small for large organs in the scan coverage (mean: 6.6%; range: 4.9%-9.2%), larger for small organs in the scan coverage (mean: 10.3%; range: 1.4%-15.6%), and the largest for organs partially or completely outside the scan coverage (mean: 14.8%; range: 5.7%-27.7%). Normalized effective dose correlated strongly with body weight (correlation coefficient: r = -0.94). Normalized dose to the kidney and the adrenal gland correlated strongly with mid-liver equivalent diameter (kidney: r = -0.97; adrenal glands: r = -0.98). Normalized dose to the small intestine correlated strongly with mid-intestine equivalent diameter (r = -0.97). These strong correlations suggest that patient-specific dose may be estimated for any other child in the same size group who undergoes the abdomen-pelvis scan.

  7. Efficacy of a "small-changes" workplace weight loss initiative on weight and productivity outcomes.

    PubMed

    Zinn, Caryn; Schofield, Grant M; Hopkins, Will G

    2012-10-01

    The effect of weight reduction on workplace productivity is unknown. We have investigated a "small-changes" workplace weight loss intervention on weight and productivity outcomes. Overweight/obese employees at two New Zealand worksites (n = 102) received the 12-week intervention. One site received an extra 9-month weight-maintenance component. Magnitudes of effects on weight and productivity were assessed via standardization. Both groups reduced weight at 12 weeks and maintained lost weight at 12 months. There were small possible improvements in productivity at one worksite and trivial reductions at the other by 12 weeks, with little subsequent change during maintenance in either group. At an individual level, weight change was associated with at most only small improvements or small reductions in productivity. Workplace weight loss initiatives may need to be more intensive or multidimensional to enhance productivity.

  8. Disseminated Mycobacterium intracellulare infection in a broad-snouted caiman Caiman latirostris.

    PubMed

    Kik, Marja J L

    2013-11-25

    A 10 yr old broad-snouted caiman Caiman latirostris from a small Dutch animal park was presented with long-term variable periods of anorexia and weight loss. Blood chemistry showed slightly elevated uric acid levels and low ionised calcium concentration. Ultrasonographical thickening of the intestinal wall in the region of the duodenum was evident. Pathological changes were a thickening of the wall of 90% of the small intestines, enlarged spleen with multifocal white foci and an enlarged light-brown liver. Histopathological lesions consisted of disseminated granulomas in the intestinal wall, the liver and the spleen. Multinucleated giant cells and epitheloid macrophages were abundant. Ziehl-Neelsen staining showed numerous intralesional acid-fast bacteria. Polymerase chain reaction for Mycobacterium intracellulare was positive.

  9. The use of inflatable structures for re-entry of orbiting vehicles

    NASA Astrophysics Data System (ADS)

    Kendall, Robert T.; Maddox, Arthur R.

    1990-10-01

    Inflatable recovery systems offer the unique advantage that a large high-drag shape can be stored initially in a relatively small package. The resulting shapes decelerate rapidly with lower heating inputs than other types of re-entry vehicles. Recent developments have led to some light-weight materials, with little thermal protection, can withstand the heating inputs to such vehicles. As a result, inflatable recovery vehicles offer a simple, reliable and economical way to return various vehicles from orbit. This paper examines the application of this concept to a large and a small vehicle with the accompanying dynamics that might be expected. More complex systems could extend the concept to emergency personnel escape systems, payload abort and satellite recovery systems.

  10. Structure of the enzymatically synthesized fructan inulin.

    PubMed

    Heyer, A G; Schroeer, B; Radosta, S; Wolff, D; Czapla, S; Springer, J

    1998-12-15

    Construction, purification and characterization of a fusion protein of maltose-binding protein of Escherichia coli and the fructosyltransferase of Streptococcus mutans is described. With the purified protein, in vitro synthesis of inulin was performed. The obtained polysaccharide was characterized by high-performance size-exclusion chromatography (HPSEC) and static light scattering (SLS) in dilute aqueous and dimethyl sulfoxide solution. For all samples very high molecular weights between 60 x 10(6) and 90 x 10(6) g/mol and a remarkable small polydispersity index of 1.1 have been determined. Small root-mean-square radii of gyration point to a compact conformation in dilute solution. No difference between native and enzymatically synthesized inulin was observed by X-ray powder diffraction and thermoanalysis of solid samples.

  11. Miniaturized fundus camera

    NASA Astrophysics Data System (ADS)

    Gliss, Christine; Parel, Jean-Marie A.; Flynn, John T.; Pratisto, Hans S.; Niederer, Peter F.

    2003-07-01

    We present a miniaturized version of a fundus camera. The camera is designed for the use in screening for retinopathy of prematurity (ROP). There, but also in other applications a small, light weight, digital camera system can be extremely useful. We present a small wide angle digital camera system. The handpiece is significantly smaller and lighter then in all other systems. The electronics is truly portable fitting in a standard boardcase. The camera is designed to be offered at a compatible price. Data from tests on young rabbits' eyes is presented. The development of the camera system is part of a telemedicine project screening for ROP. Telemedical applications are a perfect application for this camera system using both advantages: the portability as well as the digital image.

  12. Novel high-density packaging of solid state diode pumped eye-safe laser for LIBS

    NASA Astrophysics Data System (ADS)

    Bares, Kim; Torgerson, Justin; McNeil, Laine; Maine, Patrick; Patterson, Steve

    2018-02-01

    Laser-Induced Breakdown Spectroscopy (LIBS) has proven to be a useful research tool for material analysis for decades. However, because of the amount of energy required in a few nanosecond pulse to generate a stable and reliable LIBS signal, the lasers are often large and inefficient, relegating their implementation to research facilities, factory floors, and assembly lines. Small portable LIBS systems are now possible without having to compromise on energy needs by leveraging off of advances in high-density packaging of electronics, opto-mechanics, and highly efficient laser resonator architecture. This paper explores the integration of these techniques to achieve a mJ class eye-safe LIBS laser source, while retaining a small, light-weight package suitable for handheld systems.

  13. Polymer/Carbon Nanotube Networks for Smart, Self-Repairing and Light-Weighted Nanocomposites

    DTIC Science & Technology

    2012-11-05

    was develop smart, strong, and light-weight polymer/carbon nanotube (CNT) composites which will sense tribologically induced damages and self-heal by...light-weight polymer/carbon nanotube (CNT) composites which will sense tribologically induced damages and self-heal by inhibiting such degradation...one of support references for EPSRC instrument grant application for Micro Materials NanoTest Vantage Testing Suite with NTX4Controller. The grant

  14. Characterization of seed nuclei in glucagon aggregation using light scattering methods and field-flow fractionation

    PubMed Central

    Hoppe, Cindy C; Nguyen, Lida T; Kirsch, Lee E; Wiencek, John M

    2008-01-01

    Background Glucagon is a peptide hormone with many uses as a therapeutic agent, including the emergency treatment of hypoglycemia. Physical instability of glucagon in solution leads to problems with the manufacture, formulation, and delivery of this pharmaceutical product. Glucagon has been shown to aggregate and form fibrils and gels in vitro. Small oligomeric precursors serve to initiate and nucleate the aggregation process. In this study, these initial aggregates, or seed nuclei, are characterized in bulk solution using light scattering methods and field-flow fractionation. Results High molecular weight aggregates of glucagon were detected in otherwise monomeric solutions using light scattering techniques. These aggregates were detected upon initial mixing of glucagon powder in dilute HCl and NaOH. In the pharmaceutically relevant case of acidic glucagon, the removal of aggregates by filtration significantly slowed the aggregation process. Field-flow fractionation was used to separate aggregates from monomeric glucagon and determine relative mass. The molar mass of the large aggregates was shown to grow appreciably over time as the glucagon solutions gelled. Conclusion The results of this study indicate that initial glucagon solutions are predominantly monomeric, but contain small quantities of large aggregates. These results suggest that the initial aggregates are seed nuclei, or intermediates which catalyze the aggregation process, even at low concentrations. PMID:18613970

  15. Structure design of the telescope for Small-JASMINE program

    NASA Astrophysics Data System (ADS)

    Utsunomiya, Shin; Yasuda, Susumu; Yano, Taihei; Niwa, Yoshito; Kobayashi, Yukiyasu; Kashima, Shingo; Goda, Naoteru; Yamada, Yoshiyuki

    2014-08-01

    Small-JASMINE program (Japan Astrometry Satellite Mission for INfrared Exploration) is one of applicants for JAXA (Japan Aerospace Exploration Agency) space science missions launched by Epsilon Launch Vehicles, and now being reviewed in the Science Committee of ISAS (Institute of Space and Astronautical Science), JAXA. Telescope of 300 mm aperture diameter will focus to the central region of the Milky Way Galactic. The target of Small-JASMINE is to obtain reliable measurements of extremely small stellar motions with the highest accuracy of 10 μ arcseconds and to provide precise distances and velocities of multitudes of stars up to 30,000 light years. Preliminary Structure design of Small- JASMINE has been done and indicates to satisfy all of requirements from the mission requirement, the system requirement, Epsilon Launch conditions and interfaces of the small science satellite standard bus. High margin of weight for the mission allows using all super invar structure that may reduce unforeseen thermal distortion risk especially caused by connection of different materials. Thermal stability of the telescope is a key issue and should be verified in a real model at early stage of the development.

  16. RICOR Cryocoolers for HOT IR detectors from development to optimization for industrialized production

    NASA Astrophysics Data System (ADS)

    Levin, Eli; Katz, Amiram; Bar Haim, Zvi; Nachman, Ilan; Riabzev, Sergey; Gover, Dan; Segal, Victor; Filis, Avishai

    2017-05-01

    The modern needs of the electro-optical market for small low-power and light-weight IR systems are impelling research and development of High Operating Temperature (HOT) IR detectors, requiring development of dedicated "HOT" cryocoolers. The development of cryocoolers with emphasis on the "SWAP3" configuration means small size, low weight, improved performance, low power consumption and low price, in order to optimize IDDCA for future hand held thermal sights. This paper will present the development and the progress made with the new "HOT" cryocooler, including customer data after the evaluation process, performances achieved using a common cold finger, test results update on a large series of production coolers, life and qualification test update and acoustic noise reduction. All the above mentioned information relates to the FPA temperature range of 130 - 200K for various cryocooler models based on rotary and linear design concepts. The paper will also review the progress with the latest development activities implemented in the cryocoolers and the electronic control modules in order to improve reliability and minimize regulated power consumption.

  17. Lamellar Biogels: Fluid-Membrane-Based Hydrogels Containing Polymer Lipids

    NASA Astrophysics Data System (ADS)

    Warriner, Heidi E.; Idziak, Stefan H. J.; Slack, Nelle L.; Davidson, Patrick; Safinya, Cyrus R.

    1996-02-01

    A class of lamellar biological hydrogels comprised of fluid membranes of lipids and surfactants with small amounts of low molecular weight poly(ethylene glycol)-derived polymer lipids (PEG-lipids) were studied by x-ray diffraction, polarized light microscopy, and rheometry. In contrast to isotropic hydrogels of polymer networks, these membrane-based birefringent liquid crystalline biogels, labeled Lα,g, form the gel phase when water is added to the liquid-like lamellar L_α phase, which reenters a liquid-like mixed phase upon further dilution. Furthermore, gels with larger water content require less PEG-lipid to remain stable. Although concentrated (~50 weight percent) mixtures of free PEG (molecular weight, 5000) and water do not gel, gelation does occur in mixtures containing as little as 0.5 weight percent PEG-lipid. A defining signature of the Lα,g regime as it sets in from the fluid lamellar L_α phase is the proliferation of layer-dislocation-type defects, which are stabilized by the segregation of PEG-lipids to the defect regions of high membrane curvature that connect the membranes.

  18. Effects of an enriched housing environment on sensory aspects and fatty-acid composition of the longissimus muscle of light-weight finished lambs.

    PubMed

    Aguayo-Ulloa, L A; Pascual-Alonso, M; Campo, M M; Olleta, J L; Villarroel, M; Pizarro, D M; Miranda-de la Lama, G C; María, G A

    2014-08-01

    We analysed the effect of enriched housing on the sensory meat quality and fatty acid composition of longissimus muscle in 60 entire Rasa Aragonesa lambs, housed indoors for 5 weeks in six pens (10 lambs/pen, 0.95 m(2)/lamb, initial weight 17.13±0.18 kg and carcass mean 12.23±0.23 kg); three control pens (barren) and three enriched pens (straw, platform with ramps and a small ramp). The final weight, carcass weight, fatness scores and cooking losses of meat from enriched lambs (EG) were higher and pH 24 was lower (P ≤ 0.05). The EG lambs had more C18:0 and total SFA (P ≤ 0.05). Lamb odour and grass odour were more intense in EG (P ≤ 0.05). Overall liking was higher for EG (P ≤ 0.05) and associated with tenderness (P ≤ 0.0001). The results suggest that environmental enrichment can have effects on fatty acid composition and sensory meat quality. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. The influence of non-nociceptive factors on hot-plate latency in rats.

    PubMed

    Gunn, Amanda; Bobeck, Erin N; Weber, Ceri; Morgan, Michael M

    2011-02-01

    The hot plate is a widely used test to assess nociception. The effect of non-nociceptive factors (weight, sex, activity, habituation, and repeated testing) on hot-plate latency was examined. Comparison of body weight and hot-plate latency revealed a small but significant inverse correlation (light rats had longer latencies). Habituating rats to the test room for 1 hour prior to testing did not decrease hot-plate latency except for female rats tested on days 2 to 4. Hot-plate latency decreased with repeated daily testing, but this was not caused by a decrease in locomotor activity or learning to respond. Activity on the hot plate was consistent across all 4 trials, and prior exposure to a room-temperature plate caused a similar decrease in latency as rats tested repeatedly on the hot plate. Despite this decrease in baseline hot-plate latency, there was no difference in morphine antinociceptive potency. The present study shows that weight, habituation to the test room, and repeated testing can alter baseline hot-plate latency, but these effects are small and have relatively little impact on morphine antinociception. This manuscript shows that non-nociceptive factors such as body weight, habituation, and repeated testing can alter hot-plate latency, but these factors do not alter morphine potency. In sum, the hot-plate test is an easy to use and reliable method to assess supraspinally organized nociceptive responses. Copyright © 2011 American Pain Society. Published by Elsevier Inc. All rights reserved.

  20. Noise and light exposures for extremely low birth weight newborns during their stay in the neonatal intensive care unit.

    PubMed

    Lasky, Robert E; Williams, Amber L

    2009-02-01

    The objectives of this study were to characterize noise and light levels for extremely low birth weight newborns throughout their stay in the NICU, evaluate factors influencing noise and light levels, and determine whether exposures meet recommendations from the American Academy of Pediatrics. Sound and light were measured inside the beds of extremely low birth weight newborns (n = 22) from birth to discharge. Measurements were recorded for 20 consecutive hours weekly from birth until 36 weeks' postmenstrual age, biweekly until 40 weeks, and every 4 weeks thereafter. Clinical variables including bed type and method of respiratory support were recorded at each session. Age-related changes in respiratory support and bed type explained the weekly increase of 0.22 dB in sound level and 3.67 lux in light level. Old incubators were the noisiest bed types, and new incubators were the quietest. Light levels were significantly higher in open beds than in incubators. The variations in noise and light levels over time were greatest for open beds. Noise and light levels were much less affected by respiratory support in incubators compared with open beds. A typical extremely low birth weight neonate was exposed to noise levels averaging 56.44 dB(A) and light levels averaging 70.56 lux during their stay from 26 to 42 weeks' postmenstrual age in the NICU. Noise levels were rarely within American Academy of Pediatrics recommendations (5.51% of the time), whereas light levels almost always met recommendations (99.37% of the time). Bed type and respiratory support explained differences in noise and light levels that extremely low birth weight newborns experience during their hospital stay. Noise levels exceeded recommendations, although evidence supporting those recommendations is lacking. Well-designed intervention studies are needed to determine the effects of noise reduction on the development of extremely low birth weight newborns.

  1. Weight Reduction Potential of Automobiles and Light Trucks: 1980 Summary Source Document

    DOT National Transportation Integrated Search

    1981-06-01

    This report provides an assessment of the potential of weight reduction for passenger cars and light trucks (including pickup trucks, vans, and utility vehicles of GVWR up to 8500 pounds) in the post-1985 period. Vehicle characteristics and weight re...

  2. A Heavy Heart: The Association between Weight and Emotional Words.

    PubMed

    Zhao, Xueru; He, Xianyou; Zhang, Wei

    2016-01-01

    People often express emotion in language using weight (e.g., a heavy heart, light-hearted, light humor, or heavy-handed), but the question remains whether these expressions of emotion are rooted in the body. Six experiments used a priming paradigm to explore the metaphoric relation between weight perception and emotional words. Experiments 1 and 2 investigated the influence of weight perception on judgments of emotional words and the influence of emotional words on judgments of weight, respectively. A significant difference between the consistent condition (e.g., lightness corresponds to positive words and heaviness corresponds to negative words) and the inconsistent condition (e.g., lightness corresponds to negative words and heaviness corresponds to positive words) was found in Experiment 1 but not in Experiment 2. Experiments 3, 4, and 5 were conducted to exclude potential confounds. Experiment 6 was a repeated-measures study that was conducted to verify the weight-emotion effect. The study confirmed that weight perception affected judgments of emotional words. The results contribute to the growing literature on conceptual metaphor theory and embodied cognition theory.

  3. Effects of seed mass on seedling success in Artocarpus heterophyllus L., a tropical tree species of north-east India

    NASA Astrophysics Data System (ADS)

    Khan, M. L.

    2004-03-01

    I examined the effects of seed mass on performance of seedlings of Artocarpus heterophyllus L. (Moraceae), a large evergreen late successional shade-tolerant tree species in three contrasting light conditions. Seed mass varied many fold from 1.5 to 14 g in A. heterophyllus. Germination and germination time showed a significant correlation with seed mass. Germination differed significantly among three light regimes (50%, 25% and 3%). Seed mass and light level significantly affected seedling survival. The seedlings that emerged from large seeds survived better than those from small seeds under all light regimes. Survival of seedlings was maximum in 25% light regime for all seed mass classes but did not differ significantly from that at 50% light regime. Survival was significantly lower in 3% light as compared to 50% and 25% light regimes. Seedling vigor (expressed in terms of seedling height, leaf area and dry weight) was also significantly affected by seed mass and light regimes. Seedlings that emerged from larger seeds and grew under 50% light regime produced the heaviest seedlings, while those resulting from smaller seeds and grown under 3% light regime produced the lightest seedlings. Resprouting capacity of seedlings after clipping was significantly affected by seed mass and light regime. Seedlings emerging from larger seeds were capable of resprouting several times successively. Resprouting was more pronounced under 50% and 25% light regimes as compared to 3% light. Success of A. heterophyllus regeneration appears to be regulated by an interactive effect of seed mass and light regime.

  4. VTT's Fabry-Perot interferometer technologies for hyperspectral imaging and mobile sensing applications

    NASA Astrophysics Data System (ADS)

    Rissanen, Anna; Guo, Bin; Saari, Heikki; Näsilä, Antti; Mannila, Rami; Akujärvi, Altti; Ojanen, Harri

    2017-02-01

    VTT's Fabry-Perot interferometers (FPI) technology enables creation of small and cost-efficient microspectrometers and hyperspectral imagers - these robust and light-weight sensors are currently finding their way into a variety of novel applications, including emerging medical products, automotive sensors, space instruments and mobile sensing devices. This presentation gives an overview of our core FPI technologies with current advances in generation of novel sensing applications including recent mobile technology demonstrators of a hyperspectral iPhone and a mobile phone CO2 sensor, which aim to advance mobile spectroscopic sensing.

  5. Locking mechanism for orthopedic braces

    NASA Technical Reports Server (NTRS)

    Chao, J. I.; Epps, C. H., Jr.

    1981-01-01

    An orthopedic brace locking mechanism is described which under standing or walking conditions cannot be unlocked, however under sitting conditions the mechanism can be simply unlocked so as to permit bending of the patient's knee. Other features of the device include: (1) the mechanism is rendered operable, and inoperable, dependent upon the relative inclination of the brace with respect to the ground; (2) the mechanism is automatically locked under standing or walking conditions and is manually unlocked under sitting conditions; and (3) the mechanism is light in weight and is relatively small in size.

  6. Cost-effective optical switch matrix for microwave phased-array

    NASA Technical Reports Server (NTRS)

    Pan, J. J.; Chia, S. L.; Li, W. Z.; Grove, C. H.

    1991-01-01

    An all-fiber (6x6) optical shutter switch matrix with the control system for microwave phased array has been demonstrated. The device offers the advantages of integrated configuration, low cost, low power consumption, small size, and light weight. The maximum extinction ratio (among 36 individual pixel) of this switch matrix at 840 nm is 24.2 dB, and the switching time is less than 120 microsec. In addition to phased array application, this low cost switch matrix is extremely attractive for fiber optic switching networks.

  7. Effects of supplementary lighting by natural light for growth of Brassica chinensis

    NASA Astrophysics Data System (ADS)

    Yeh, Shih-Chuan; Lee, Hui-Ping; Kao, Shih-Tse; Lu, Ju-Lin

    2016-04-01

    This paper present a model of cultivated chamber with supplementary natural colour light. We investigate the effects of supplementary natural red light and natural blue light on growth of Brassica chinensis under natural white light illumination. After 4 weeks of supplementary colour light treatment, the experiment results shown that the weight of fresh leaf were not affected by supplementary natural blue light. However, those Brassica chinensis were cultivated in the chambers with supplementary natural red light obtained a significant increasing of fresh weight of leaf under both white light illuminate models. The combination of natural white light with supplementary natural red light illumination will be benefits in growth for cultivation and energy saving.

  8. Green Light-emitting Diodes Light Stimuli during Incubation Enhances Posthatch Growth without Disrupting Normal Eye Development of Broiler Embryos and Hatchlings.

    PubMed

    Zhang, L; Zhu, X D; Wang, X F; Li, J L; Gao, F; Zhou, G H

    2016-11-01

    Monochromatic green light-emitting diodes (LED) light stimuli influences the posthatch growth performance of chicks. This study was undertaken with the following objectives: i) to examine whether the green LED light stimuli induces an overheating effect by determining weight loss rate of fertile eggs during incubation period; ii) to look for the development of eyes and other primary organs at different ages of embryos and newly hatched chicks. Arbor Acres fertile broiler eggs (n = 480) were randomly assigned to 3 incubation groups and exposed to continuous white light, green light, or a dark environment (control) from the first day to 19 d of incubation. The light sourced from LED lamps with the intensity of 30 lx at eggshell level. The results showed that either green or white light stimuli during incubation did not significantly affect the weight loss rate of fertile eggs, hatching time, hatchability, chick embryo, or body weight (BW), the weight percentage of heart, liver, and eyes, as well as obvious systematic abnormalities in eye weight, side-to-side, back-to-front, or corneal diameter from 15 d of embryogenesis to 6 d of posthatch (p>0.05). Compared with the dark condition, green light stimuli during incubation tended to increase feed intake (p = 0.080), improved the BW gain of chicks during 0 to 6 day posthatch (p<0.05), and increased the percentage of pectoral muscle to the BW on 3- and 6-day-old chicks. In addition, embryos or chicks in green light had lower weight percentage of yolk retention on 19 d of embryogenesis and 1 d of posthatch in comparison to those in dark or white group (p<0.05). These results suggest that providing 30 lx green LED light stimuli during incubation has no detrimental effect on the development of eyes, heart and liver of embryos and hatchlings, but does have potential benefits in terms of enhancement of the chick growth during the early posthatch stages. In addition, the fertile broiler eggs stimulated with 30 lx green LED light during incubation does not cause an overheating effect.

  9. Effects of Light and Temperature on the Association between Zea mays and Spirillum lipoferum1

    PubMed Central

    Albrecht, Stephan L.; Okon, Yaacov; Burris, Robert H.

    1977-01-01

    Zea mays was grown on a low N nutrient solution under 16 conditions of light and temperature in a crossed-gradient room in an attempt to determine whether or not variation in climatic conditions influences N2 fixation by the association between maize and Spirillum lipoferum. Temperatures were 28, 32, 36, and 40 C and 10 C lower at night; light intensities were 500, 1,250, 2,400, and 3,000 ft-c. Plants harvested after 94 days showed no significant benefit from association with S. lipoferum either in dry weight production or in total N content; variations in temperature and light had only a small influence on N2 fixation under the conditions tested. Measurements of total N, together with designated assumptions, indicated that less than the equivalent of 0.5 kilogram of N was fixed/hectare during the entire growing period by the maize-S. lipoferum association. Rates of C2H2 reduction by replicate root samples generally were low and variable and did not correlate with the measurements of total N. PMID:16660131

  10. In vivo light dosimetry for HPPH-mediated pleural PDT

    NASA Astrophysics Data System (ADS)

    Dimofte, Andreea; Zhu, Timothy C.; Finlay, Jarod C.; Cullighan, Melissa; Edmonds, Christine E.; Friedberg, Joseph S.; Cengel, Keith; Hahn, Stephen M.

    2010-02-01

    This study examines the light fluence (rate) delivered to patients undergoing pleural PDT as a function of treatment time, treatment volume and surface area. The accuracy of treatment delivery is analyzed as a function of the calibration accuracies of each isotropic detector and the calibration integrating sphere. The patients studied here are enrolled in a Phase I clinical trial of HPPH-mediated PDT for the treatment of non-small cell lung cancer with pleural effusion. Patients are administered 4mg per kg body weight HPPH 24-48 hours before the surgery. Patients undergoing photodynamic therapy (PDT) are treated with light therapy with a fluence of 15-60 J/cm2 at 661nm. Fluence rate (mW/cm2) and cumulative fluence (J/cm2) is monitored at 7 different sites during the entire light treatment delivery. Isotropic detectors are used for in-vivo light dosimetry. The anisotropy of each isotropic detector was found to be within 15%. The mean fluence rate delivery and treatment time are recorded. A correlation between the treatment time and the treatment volume is established. The result can be used as a clinical guideline for future pleural PDT treatment.

  11. Fiber-Optic Sensor for Aircraft Lightning Current Measurement

    NASA Technical Reports Server (NTRS)

    Nguyen, Truong X.; Ely, Jay J.; Szatkowski, George G.; Mata, Carlos T.; Mata,Angel G.; Snyder, Gary P.

    2012-01-01

    An electric current sensor based on Faraday rotation effect in optical fiber was developed for measuring aircraft lightning current. Compared to traditional sensors, the design has many advantages including the ability to measure total current and to conform to structure geometries. The sensor is also small, light weight, non-conducting, safe from interference, and free of hysteresis and saturation. Potential applications include characterization of lightning current waveforms, parameters and paths, and providing environmental data for aircraft certifications. In an optical fiber as the sensing medium, light polarization rotates when exposed to a magnetic field in the direction of light propagation. By forming closed fiber loops around a conductor and applying Ampere s law, measuring the total light rotation yields the enclosed current. A reflective polarimetric scheme is used, where polarization change is measured after the polarized light travels round-trip through the sensing fiber. The sensor system was evaluated measuring rocket-triggered lightning over the 2011 summer. Early results compared very well against a reference current shunt resistor, demonstrating the sensor's accuracy and feasibility in a lightning environment. While later comparisons show gradually increasing amplitude deviations for an undetermined cause, the overall waveforms still compared very well.

  12. Fiber-Optic Sensor for Aircraft Lightning Current Measurement

    NASA Technical Reports Server (NTRS)

    Nguyen, Truong X.; Ely, Jay J.; Szatkowski, George G.; Mata, Carlos T.; Mata, Angel G.; Snyder, Gary P.

    2012-01-01

    An electric current sensor based on Faraday rotation effect in optical fiber was developed for measuring aircraft lightning current. Compared to traditional sensors, the design has many advantages including the ability to measure total current and to conform to structure geometries. The sensor is also small, light weight, non-conducting, safe from interference, and free of hysteresis and saturation. Potential applications include characterization of lightning current waveforms, parameters and paths, and providing environmental data for aircraft certifications. In an optical fiber as the sensing medium, light polarization rotates when exposed to a magnetic field in the direction of light propagation. By forming closed fiber loops around a conductor and applying Ampere s law, measuring the total light rotation yields the enclosed current. A reflective polarimetric scheme is used, where polarization change is measured after the polarized light travels round-trip through the sensing fiber. The sensor system was evaluated measuring rocket-triggered lightning over the 2011 summer. Early results compared very well against a reference current shunt resistor, demonstrating the sensor s accuracy and feasibility in a lightning environment. While later comparisons show gradually increasing amplitude deviations for an undetermined cause, the overall waveforms still compared very well.

  13. Selection for intramuscular fat and lean meat yield will improve the bloomed colour of Australian lamb loin meat.

    PubMed

    Calnan, H B; Jacob, R H; Pethick, D W; Gardner, G E

    2017-09-01

    The colour of bloomed m. longissimus was measured 24h post slaughter for 8165 lamb carcasses produced over 5years across 8 sites in Australia. Intramuscular fat across a 2 to 8% range and shortloin fat weight were positively associated with meat lightness (L*), redness (a*), yellowness (b*), hue and chroma (P<0.01). Shortloin muscle weight was negatively associated with these meat colour parameters (P<0.01), although this was largely accounted for by correlated changes in intramuscular fat (P<0.01). The effect of sire breeding values for lamb weight, shortloin muscle depth and fat depth on loin L*, a*, b*, hue and chroma were small and varied between lambs of different sire type, dam breed and sex. Thus selection for lean meat yield will have neutral or positive effects on meat colour, while selection for increased intramuscular fat will make the bloomed colour of lamb meat lighter and redder. Copyright © 2017. Published by Elsevier Ltd.

  14. Effects of breeder age and egg weight on morphological changes in the small intestine of chicks during the hatch window.

    PubMed

    Yalçin, S; Izzetoğlu, G T; Aktaş, A

    2013-01-01

    1. The objective of the study was to investigate the effects of breeder age and egg weight on hatching performance and morphological changes in segments of the small intestine of broiler chicks during a 21 h hatch window. 2. Eggs from Ross broiler breeder flocks aged 29 (young) and 48 weeks (old) were classified as light (LE) or heavy (HE) and incubated at the same conditions. At 475 h of incubation, eggs were checked every 3 h to determine time of external pipping and hatching. The first 42 chicks to emerge from each group were weighed and chick length was measured and 14 chicks from each group were sampled to collect residual yolk and intestine segments. The rest of chicks were placed back in the incubator and chick weight and length were measured individually at 9, 15 and 21 h after chicks hatched. At the end of 21 h, 14 chicks from each group were sampled again and the same procedure was followed. 3. The HE chicks pipped and hatched later than LE, regardless of breeder age. From hatch to the end of the hatch window, chick weight, but not yolk-free chick weight, gradually reduced. Relative residual yolk weight of chicks from both egg weights was similar at hatch, however, yolk sac utilisation was higher for LE chicks during the 21 h post-hatch period. At hatch, jejunum and ileum villus development was very similar for HE and LE chicks but greater development was observed for villus area with an increase in the jejunum villus length, width and goblet cell numbers in HE chicks. 4. The longest jejunum villus and the widest duodenum and jejunum villus were obtained for HE chicks from old breeders indicating that HE chicks from old breeders would have a greater surface area for nutrient absorption.

  15. Mulifunctional Dendritic Emitter: Aggregation-Induced Emission Enhanced, Thermally Activated Delayed Fluorescent Material for Solution-Processed Multilayered Organic Light-Emitting Diodes

    PubMed Central

    Matsuoka, Kenichi; Albrecht, Ken; Yamamoto, Kimihisa; Fujita, Katsuhiko

    2017-01-01

    Thermally activated delayed fluorescence (TADF) materials emerged as promising light sources in third generation organic light-emitting diodes (OLED). Much effort has been invested for the development of small molecular TADF materials and vacuum process-based efficient TADF-OLEDs. In contrast, a limited number of solution processable high-molecular weight TADF materials toward low cost, large area, and scalable manufacturing of solution processed TADF-OLEDs have been reported so far. In this context, we report benzophenone-core carbazole dendrimers (GnB, n = generation) showing TADF and aggregation-induced emission enhancement (AIEE) properties along with alcohol resistance enabling further solution-based lamination of organic materials. The dendritic structure was found to play an important role for both TADF and AIEE activities in the neat films. By using these multifunctional dendritic emitters as non-doped emissive layers, OLED devices with fully solution processed organic multilayers were successfully fabricated and achieved maximum external quantum efficiency of 5.7%. PMID:28139768

  16. Mulifunctional Dendritic Emitter: Aggregation-Induced Emission Enhanced, Thermally Activated Delayed Fluorescent Material for Solution-Processed Multilayered Organic Light-Emitting Diodes

    NASA Astrophysics Data System (ADS)

    Matsuoka, Kenichi; Albrecht, Ken; Yamamoto, Kimihisa; Fujita, Katsuhiko

    2017-01-01

    Thermally activated delayed fluorescence (TADF) materials emerged as promising light sources in third generation organic light-emitting diodes (OLED). Much effort has been invested for the development of small molecular TADF materials and vacuum process-based efficient TADF-OLEDs. In contrast, a limited number of solution processable high-molecular weight TADF materials toward low cost, large area, and scalable manufacturing of solution processed TADF-OLEDs have been reported so far. In this context, we report benzophenone-core carbazole dendrimers (GnB, n = generation) showing TADF and aggregation-induced emission enhancement (AIEE) properties along with alcohol resistance enabling further solution-based lamination of organic materials. The dendritic structure was found to play an important role for both TADF and AIEE activities in the neat films. By using these multifunctional dendritic emitters as non-doped emissive layers, OLED devices with fully solution processed organic multilayers were successfully fabricated and achieved maximum external quantum efficiency of 5.7%.

  17. Regression Model for Light Weight and Crashworthiness Enhancement Design of Automotive Parts in Frontal CAR Crash

    NASA Astrophysics Data System (ADS)

    Bae, Gihyun; Huh, Hoon; Park, Sungho

    This paper deals with a regression model for light weight and crashworthiness enhancement design of automotive parts in frontal car crash. The ULSAB-AVC model is employed for the crash analysis and effective parts are selected based on the amount of energy absorption during the crash behavior. Finite element analyses are carried out for designated design cases in order to investigate the crashworthiness and weight according to the material and thickness of main energy absorption parts. Based on simulations results, a regression analysis is performed to construct a regression model utilized for light weight and crashworthiness enhancement design of automotive parts. An example for weight reduction of main energy absorption parts demonstrates the validity of a regression model constructed.

  18. Real-time range acquisition by adaptive structured light.

    PubMed

    Koninckx, Thomas P; Van Gool, Luc

    2006-03-01

    The goal of this paper is to provide a "self-adaptive" system for real-time range acquisition. Reconstructions are based on a single frame structured light illumination. Instead of using generic, static coding that is supposed to work under all circumstances, system adaptation is proposed. This occurs on-the-fly and renders the system more robust against instant scene variability and creates suitable patterns at startup. A continuous trade-off between speed and quality is made. A weighted combination of different coding cues--based upon pattern color, geometry, and tracking--yields a robust way to solve the correspondence problem. The individual coding cues are automatically adapted within a considered family of patterns. The weights to combine them are based on the average consistency with the result within a small time-window. The integration itself is done by reformulating the problem as a graph cut. Also, the camera-projector configuration is taken into account for generating the projection patterns. The correctness of the range maps is not guaranteed, but an estimation of the uncertainty is provided for each part of the reconstruction. Our prototype is implemented using unmodified consumer hardware only and, therefore, is cheap. Frame rates vary between 10 and 25 fps, dependent on scene complexity.

  19. Lab Demonstration of the Hybrid Doppler Wind Lidar (HDWL) Transceiver

    NASA Technical Reports Server (NTRS)

    Marx, Catherine T.; Gentry, Bruce; Jordan, Patrick; Dogoda, Peter; Faust, Ed; Kavaya, Michael

    2013-01-01

    The recommended design approach for the 3D Tropospheric Winds mission is a hybrid Doppler lidar which combines the best elements of both a coherent aerosol Doppler lidar operating at 2 micron and a direct detection molecular Doppler lidar operating at 0.355 micron. In support of the mission, we built a novel, compact, light-weighted multi-field of view transceiver where multiple telescopes are used to cover the required four fields of view. A small mechanism sequentially selects both the "transmit" and "receive" fields of view. The four fields are combined to stimulate both the 0.355 micron receiver and the 2 micron receiver. This version is scaled (0.2 micron diameter aperture) from the space-based version but still demonstrates the feasibility of the hybrid approach. The primary mirrors were conventionally light-weighted and coated with dielectric, high reflectivity coatings with high laser damage thresholds at both 2 micron and 0.355 micron. The mechanical structure and mounts were fabricated from composites to achieve dimensional stability while significantly reducing the mass. In the laboratory, we demonstrated the system level functionality at 0.355 micron and at 2 micron raising the Technology Readiness Level (TRL) from 2 to 4.

  20. Lab Demonstration of the Hybrid Doppler Wind Lidar (HDWL) Transceiver

    NASA Technical Reports Server (NTRS)

    Marx, Catherine T.; Gentry, Bruce; Jordan, Patrick; Dogoda, Peter; Faust, Ed; Kavaya, Michael

    2013-01-01

    The recommended design approach for the 3D Tropospheric Winds mission is a hybrid Doppler lidar which combines the best elements of both a coherent aerosol Doppler lidar operating at 2 microns and a direct detection molecular Doppler lidar operating at 0.355 microns. In support of the mission, we built a novel, compact, light-weighted multi-field of view transceiver where multiple telescopes are used to cover the required four fields of view. A small mechanism sequentially selects both the "transmit" and "receive" fields of view. The four fields are combined to stimulate both the 0.355 micron receiver and the 2 micron receiver. This version is scaled (0.2 m diameter aperture) from the space-based version but still demonstrates the feasibility of the hybrid approach. The primary mirrors were conventionally light-weighted and coated with dielectric, high reflectivity coatings with high laser damage thresholds at both 2 microns and 0.355 microns. The mechanical structure and mounts were fabricated from composites to achieve dimensional stability while significantly reducing the mass. In the laboratory, we demonstrated the system level functionality at 0.355 microns and at 2 microns, raising the Technology Readiness Level (TRL) from 2 to 4.

  1. Advanced photovoltaic power systems using tandem GaAs/GaSb concentrator modules

    NASA Technical Reports Server (NTRS)

    Fraas, L. M.; Kuryla, M. S.; Pietila, D. A.; Sundaram, V. S.; Gruenbaum, P. E.; Avery, J. E.; Dihn, V.; Ballantyne, R.; Samuel, C.

    1992-01-01

    In 1989, Boeing announced the fabrication of a tandem gallium concentrator solar cell with an energy conversion efficiency of 30 percent. This research breakthrough has now led to panels which are significantly smaller, lighter, more radiation resistant, and potentially less expensive than the traditional silicon flat plate electric power supply. The new Boeing tandem concentrator (BTC) module uses an array of lightweight silicone Fresnel lenses mounted on the front side of a light weight aluminum honeycomb structure to focus sunlight onto small area solar cells mounted on a thin back plane. This module design is shown schematically. The tandem solar cell in this new module consists of a gallium arsenide light sensitive cell with a 24 percent energy conversion efficiency stacked on top of a gallium antimonide infrared sensitive cell with a conversion efficiency of 6 percent. This gives a total efficiency 30 percent for the cell-stack. The lens optical efficiency is typically 85 percent. Discounting for efficiency losses associated with lens packing, cell wiring, and cell operating temperature still allows for a module efficiency of 22 percent which leads to a module power density of 300 Watts/sq. m. This performance provides more than twice the power density available from a single crystal silicon flat plate module and at least four times the power density available from amorphous silicon modules. The fact that the lenses are only 0.010 ft. thick and the aluminum foil back plane is only 0.003 ft. thick leads to a very lightweight module. Although the cells are an easy to handle thickness of 0.020 ft., the fact that they are small, occupying one-twenty-fifth of the module area, means that they add little to the module weight. After summing all the module weights and given the high module power, we find that we are able to fabricate BTC modules with specific power of 100 watts/kg.

  2. The influence of parenting style on health related behavior of children: findings from the ChiBS study.

    PubMed

    Philips, Nele; Sioen, Isabelle; Michels, Nathalie; Sleddens, Ester; De Henauw, Stefaan

    2014-07-23

    Exploring associations between parenting behavior and children's health related behavior including physical activity, sedentary behavior, diet and sleep. We recruited 288 parents and their children (6-12y old). Children's weight and height were measured. Fat percentage was determined by air displacement plethysmography. Parents reported socio-demographic data, sleep information, physical activity and sedentary behavior of their child and completed the Comprehensive General Parenting Questionnaire (CGPQ) and a Food Frequency Questionnaire. Children completed the Dutch Eating Behavior Questionnaire. Associations between parenting behavior (CGPQ) and children's health related behavior were assessed with univariate and multiple regression analyses. A small positive correlation was found between sweet food consumption frequency and "coercive control" (r = 0.139) and a small negative correlation between fruit and vegetables consumption frequency and "overprotection" (r = -0.151). Children consumed more frequently soft drinks when their parents scored lower on "structure" (r = -0.124) and higher on "overprotection" (r = 0.123); for the light soft drinks separately, a small positive correlation with "behavioral control" was found (r = 0.172). A small negative correlation was found between "emotional eating" and "structure" (r = -0.172) as well as "behavioral control" (r = -0.166). "Coercive control" was negatively correlated with the child's sleep duration (r = -0.171). After correction for confounding factors, the following significant associations were found: (1) a small negative association between "structure" and soft drinks consumption (β = -0.17 for all soft drinks and -0.22 for light soft drinks), (2) a small positive association between "behavioral control" and light soft drinks (β = 0.34), (3) a small positive association of "nurturance" and "coercive control" with sedentary behavior (β = 0.16 for both parent constructs) and (4) a small negative association between the parenting construct "coercive control" and sleep duration (β = -0.23). The significant but small associations between parenting constructs and the investigated variables suggest that different aspects of parenting style play an important role in the genesis of the health related behavior of children. Overall, our findings suggest that health professionals should encourage parents to apply the more positive parenting constructs i.e., more "structure" and "behavioral control", and less "coercive control". They could, for instance, supervise and manage their child's activities and help their child to achieve certain goals.

  3. Extraction and labeling methods for microarrays using small amounts of plant tissue.

    PubMed

    Stimpson, Alexander J; Pereira, Rhea S; Kiss, John Z; Correll, Melanie J

    2009-03-01

    Procedures were developed to maximize the yield of high-quality RNA from small amounts of plant biomass for microarrays. Two disruption techniques (bead milling and pestle and mortar) were compared for the yield and the quality of RNA extracted from 1-week-old Arabidopsis thaliana seedlings (approximately 0.5-30 mg total biomass). The pestle and mortar method of extraction showed enhanced RNA quality at the smaller biomass samples compared with the bead milling technique, although the quality in the bead milling could be improved with additional cooling steps. The RNA extracted from the pestle and mortar technique was further tested to determine if the small quantity of RNA (500 ng-7 microg) was appropriate for microarray analyses. A new method of low-quantity RNA labeling for microarrays (NuGEN Technologies, Inc.) was used on five 7-day-old seedlings (approximately 2.5 mg fresh weight total) of Arabidopsis that were grown in the dark and exposed to 1 h of red light or continued dark. Microarray analyses were performed on a small plant sample (five seedlings; approximately 2.5 mg) using these methods and compared with extractions performed with larger biomass samples (approximately 500 roots). Many well-known light-regulated genes between the small plant samples and the larger biomass samples overlapped in expression changes, and the relative expression levels of selected genes were confirmed with quantitative real-time polymerase chain reaction, suggesting that these methods can be used for plant experiments where the biomass is extremely limited (i.e. spaceflight studies).

  4. A novel contrast agent with rare earth-doped up-conversion luminescence and Gd-DTPA magnetic resonance properties

    NASA Astrophysics Data System (ADS)

    Lu, Qing; Wei, Daixu; Cheng, Jiejun; Xu, Jianrong; Zhu, Jun

    2012-08-01

    The magnetic-luminescent multifunctional nanoparticles based on Gd-DTPA and NaYF4:Yb, Er were successfully synthesized by the conjugation of activated DTPA and silica-coated/surface-aminolated NaYF4:Yb, Er nanoparticles through EDC/NHS coupling chemistry. The as-prepared products were characterized by powder X-ray diffraction, transmission electron microscopy, dynamic light scattering, energy dispersive X-ray analysis, and fourier transform infrared spectrometry. The room-temperature upconversion luminescent spectra and T1-weighted maps of the obtained nanoparticles were carried out by 980 nm NIR light excitation and a 3T MR imaging scanner, respectively. The results indicated that the as-synthesized multifunctional nanoparticles with small size, highly solubility in water, and both high MR relaxivities and upconversion luminescence may have potential usage for MR imaging in future.

  5. Compact Laser System for Field Deployable Ultracold Atom Sensors

    NASA Astrophysics Data System (ADS)

    Pino, Juan; Luey, Ben; Anderson, Mike

    2013-05-01

    As ultracold atom sensors begin to see their way to the field, there is a growing need for small, accurate, and robust laser systems to cool and manipulate atoms for sensing applications such as magnetometers, gravimeters, atomic clocks and inertial sensing. In this poster we present a laser system for Rb, roughly the size of a paperback novel, capable of generating and controlling light sufficient for the most complicated of cold atom sensors. The system includes >100dB of non-mechanical, optical shuttering, the ability to create short, microsecond pulses, a Demux stage to port light onto different optical paths, and an atomically referenced, frequency agile laser source. We will present data to support the system, its Size Weight and Power (SWaP) requirements, as well as laser stability and performance. funded under DARPA

  6. Influence of pre-pregnancy leisure time physical activity on gestational and postpartum weight gain and birth weight - a cohort study.

    PubMed

    Hegaard, Hanne Kristine; Rode, Line; Katballe, Malene Kjær; Langberg, Henning; Ottesen, Bent; Damm, Peter

    2017-08-01

    In order to examine the association between pre-pregnancy leisure time physical activities and gestational weight gain, postpartum weight gain and birth weight, we analysed prospectively collected data from 1827 women with singleton term pregnancies. Women were categorised in groups of sedentary women, light exercisers, moderate exercisers and competitive athletes. The results showed that sedentary women on average gained 14.1 kg during pregnancy, whereas light exercisers gained 13.7 kg, moderate exercisers gained 14.3 kg and competitive athletes 16.1 kg. Competitive athletes had an increased risk of having a gestational weight gain above Institute of Medicine (IOM) recommendations with an odds ratio of 2.60 (1.32-5.15) compared to light exercisers. However, birth weight and one year postpartum weight was similar for all four groups. Thus, although competitive athletes gain more weight than recommended during pregnancy, this may not affect birth weight or postpartum weight. Impact statement What is already known on this subjectPrevious studies have found that increased pre-pregnancy physical activity is associated with lower gestational weight gain during the last trimester, but showed no association between the pre-pregnancy level of physical activity and mean birth weight. What the results of this study addWe found that women classified as competitive exercisers had a 2.6-fold increased risk of gaining more weight than recommended compared to light exercisers. Nearly 6 out of 10 women among the competitive exercisers gained more weight than recommended by IOM. Surprisingly, this did not appear to increase birth weight or post-partum weight gain, but other adverse effects cannot be excluded. What the implications are of these findings for clinical practice and/or further researchIn the clinical practice it may be relevant to focus on and advise pre-pregnancy competitive exercisers in order to prevent excessive gestational weight gain.

  7. Far Red and White Light-promoted Utilization of Calcium by Seedlings of Phaseolus vulgaris L.

    PubMed

    Helms, K; David, D J

    1973-01-01

    The cotyledons and embryo axes of seeds of Phaseolus vulgaris L. cv. Pinto contained 16% of the total calcium in the seed. The remaining 84% was in the testas. There was no evidence that calcium in testas was used in seedling growth or that calcium was leached from seedlings during growth.An external supply of calcium decreased the incidence of hypocotyl collapse (a severe symptom of calcium deficiency), increased the calcium content of all organs, and increased the dry weight of all organs except cotyledons. Light treatments decreased the incidence of hypocotyl collapse and increased the calcium content and dry weight of all organs except cotyledons and hypocotyls.White light was more effective than far red light for decreasing incidence of hypocotyl collapse. Usually the effects of white light and far red light on the calcium content and dry weight of organs were similar, and usually those of white light were quantitatively greater than those of far red light. It is suggested that the light-promoted effects were associated with photomorphogenesis and that differences in data obtained with white light and far red light could be associated with photosynthesis.

  8. 40 CFR 86.1772-99 - Road load power, test weight, and inertia weight class determination.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... requirements shall also apply to this subpart: (1) For electric and hybrid electric vehicle lines where it is... VEHICLES AND ENGINES (CONTINUED) General Provisions for the Voluntary National Low Emission Vehicle Program for Light-Duty Vehicles and Light-Duty Trucks § 86.1772-99 Road load power, test weight, and inertia...

  9. Light dosimetry and dose verification for pleural PDT

    NASA Astrophysics Data System (ADS)

    Dimofte, Andreea; Sharikova, Anna V.; Meo, Julia L.; Simone, Charles B.; Friedberg, Joseph S.; Zhu, Timothy C.

    2013-03-01

    In-vivo light dosimetry for patients undergoing photodynamic therapy (PDT) is critical for predicting PDT outcome. Patients in this study are enrolled in a Phase I clinical trial of HPPH-mediated PDT for the treatment of non-small cell lung cancer with pleural effusion. They are administered 4mg per kg body weight HPPH 48 hours before the surgery and receive light therapy with a fluence of 15-45 J/cm2 at 661 and 665nm. Fluence rate (mW/cm2) and cumulative fluence (J/cm2) are monitored at 7 sites during the light treatment delivery using isotropic detectors. Light fluence (rate) delivered to patients is examined as a function of treatment time, volume and surface area. In a previous study, a correlation between the treatment time and the treatment volume and surface area was established. However, we did not include the direct light and the effect of the shape of the pleural surface on the scattered light. A real-time infrared (IR) navigation system was used to separate the contribution from the direct light. An improved expression that accurately calculates the total fluence at the cavity wall as a function of light source location, cavity geometry and optical properties is determined based on theoretical and phantom studies. The theoretical study includes an expression for light fluence rate in an elliptical geometry instead of the spheroid geometry used previously. The calculated light fluence is compared to the measured fluence in patients of different cavity geometries and optical properties. The result can be used as a clinical guideline for future pleural PDT treatment.

  10. Crop yield and light/energy efficiency in a closed ecological system: Laboratory Biosphere experiments with wheat and sweet potato

    NASA Astrophysics Data System (ADS)

    Nelson, M.; Dempster, W. F.; Silverstone, S.; Alling, A.; Allen, J. P.; van Thillo, M.

    Two crop growth experiments in the soil-based closed ecological facility, Laboratory Biosphere, were conducted from 2003 to 2004 with candidate space life support crops. Apogee wheat (Utah State University variety) was grown, planted at two densities, 400 and 800 seeds m -2. The lighting regime for the wheat crop was 16 h of light - 8 h dark at a total light intensity of around 840 μmol m -2 s -1 and 48.4 mol m -2 d -1 over 84 days. Average biomass was 1395 g m -2, 16.0 g m -2 d -1 and average seed production was 689 g m -2 and 7.9 g m -2 d -1. The less densely planted side was more productive than the denser planting, with 1634 g m -2 and 18.8 g m -2 d -1 of biomass vs. 1156 g m -2 and 13.3 g m -2 d -1; and a seed harvest of 812.3 g m -2 and 9.3 g m -2 d -1 vs. 566.5 g m -2 and 6.5 g m -2 d -1. Harvest index was 0.49 for the wheat crop. The experiment with sweet potato used TU-82-155 a compact variety developed at Tuskegee University. Light during the sweet potato experiment, on a 18 h on/6 h dark cycle, totaled 5568 total moles of light per square meter in 126 days for the sweet potatoes, or an average of 44.2 mol m -2 d -1. Temperature regime was 28 ± 3 °C day/22 ± 4 °C night. Sweet potato tuber yield was 39.7 kg wet weight, or an average of 7.4 kg m -2, and 7.7 kg dry weight of tubers since dry weight was about 18.6% wet weight. Average per day production was 58.7 g m -2 d -1 wet weight and 11.3 g m -2 d -1. For the wheat, average light efficiency was 0.34 g biomass per mole, and 0.17 g seed per mole. The best area of wheat had an efficiency of light utilization of 0.51 g biomass per mole and 0.22 g seed per mole. For the sweet potato crop, light efficiency per tuber wet weight was 1.33 g mol -1 and 0.34 g dry weight of tuber per mole of light. The best area of tuber production had 1.77 g mol -1 wet weight and 0.34 g mol -1 of light dry weight. The Laboratory Biosphere experiment's light efficiency was somewhat higher than the USU field results but somewhat below greenhouse trials at comparable light levels, and the best portion of the crop at 0.22 g mol -1 was in-between those values. Sweet potato production was overall close to 50% higher than trials using hydroponic methods with TU-82-155 at NASA JSC. Compared to projected yields for the Mars on Earth life support system, these wheat yields were about 15% higher, and the sweet potato yields averaged over 80% higher.

  11. Crop yield and light / energy efficiency in a closed ecological system: two laboratory biosphere experiments

    NASA Astrophysics Data System (ADS)

    Nelson, M.; Dempster, W. F.; Silverstone, S.; Alling, A.; Allen, J. P.; van Thillo, M.

    Two crop growth experiments in the soil-based closed ecological facity, Laboratory Biosphere, were conducted from 2003-2004 with candidate space life support crops. Apogee wheat (Utah State University variety) was grown, planted in 2 densities, 400 and 800 seeds m-2. The lighting regime for the wheat crop was 16 hours of light -- 8 hours dark at a total light intensity of around 840 mol m2 sec-1 and 48.4 mol m-2 d-1 over 84 days Average biomass was 1395 g m-2, 16.0 g m-2 day-1 and average seed production was 689 g m-2 and 7.9 g m2 day-1. The less densely planted side was more productive than the denser planting, with 1634 g m-2 and 18.8g m-2 day-1 of biomass vs. 1156 g m-2 and 13.3 g m-2 day-1; and a seed harvest of 812.3 g m-2 and 9.3 g m-2 day-1 vs. 566.5 g m-2 and 6.5 g m-2 day-1 Harvest index was 0.49 for the wheat crop. The experiment with sweet potato used TU-82-155, a compact variety developed at Tuskegee University. Light during the sweet potato experiment, on a 16 hour on/8 hours dark cycle, totalled 5568 total moles of light in 126 days for the sweet potatoes, or an average of 44.2 moles m-2 day-1. Temperature regime was 28 deg +/- 3 deg C day /22 deg +/- 4 deg C night. Sweet potato tuber yield was 39.7 kg wet weight, or an average of 7.4 kg m-2 and 7.7 kg dry weight of tubers since dry weight was about 18.6% wet weight.^Average per day production was 58.7 g m-2 day-1 wet weight and 11.3 g m-2 day-1. For the wheat, average light efficiency was 0.34 grams biomass per mole, and 0.17 grams seed per mole. The best area of wheat had an efficiency of light utilization of 0.51 g biomass per mole and 0.22 g seed per mole. For the sweet potato crop, light efficiency per tuber wet weight was 7.13 g/mole and 1.38 g dry weight of tuber per mole of light. The best area of tuber production had 9.49 g/mole wet weight and 1.85 g/mole of light dry weight. Production from the wheat was The Laboratory Biosphere experiment's light efficiency was somewhat higher than the USU field results but somewhat below greenhouse trials at comparable light levels, and the best portion of the crop at 0.22g/mole was inbetween those values. Sweet potato production was overall close to 50% higher than trials using hydroponic methods with TU-82-155 at NASA JSC. Compared to projected yields for the Mars on Earth life support system, these wheat yields were about 15% higher, and the sweet potato yields averaged over 80% higher

  12. The Study on Development of Light-Weight Foamed Mortar for Tunnel Backfill

    NASA Astrophysics Data System (ADS)

    Ma, Sang-Joon; Kang, Eun-Gu; Kim, Dong-Min

    This study was intended to develop the Light-Weight Foamed Mortar which is used for NATM Composite lining backfill. In the wake of the study, the mixing method which satisfies the requirements for compressive strength, permeability coefficient, fluidity, specific gravity and settlement was developed and moreover field applicability was verified through the model test. Thus the mixing of Light-Weight Foamed Mortar developed in this study is expected to be applicable to NATM Composite lining, thereby making commitment to improving the stability and drainage performance of lining.

  13. Comparison of hatching egg characteristics, embryo development, yolk absorption, hatch window, and hatchability of Pekin Duck eggs of different weights.

    PubMed

    Ipek, A; Sozcu, A

    2017-10-01

    This study was carried out to determine the hatching egg characteristics, embryo development and yolk absorption during incubation, hatch window, and hatchability of Pekin duck eggs of different weights. A total of 960 hatching eggs was obtained from a breeder flock 35 to 36 wk of age. The eggs were classed into 3 weight categories: "light" (L; <75 g), "medium" (M; 76 to 82 g), and "heavy" (H; >83 g). The albumen weight was the highest in the heavy eggs, whereas the yolk weight was higher in the medium and heavy eggs. Egg breaking strength was the highest with a value of 2.5 kg/cm2 in light eggs, whereas the thinnest eggshell (0.3862 mm) was observed in heavy eggs. pH of albumen and yolk was similar and ranged from 8.8 to 8.9 and 5.9 to 6.0, respectively. On d 14 of incubation, yolk sac weight was found higher in the medium and heavy eggs. Additionally, the dry matter of the embryo and yolk sac differed among the egg weight groups during the incubation period. Interestingly, on d 25 of incubation, the embryo weight was higher in the light and heavy eggs (35.2 and 36.3 g, respectively) than in the medium eggs (29.8 g). These findings showed that embryo growth was affected by yolk absorption and dry matter accumulation. The hatchability of total and fertile eggs was lower for the heavy eggs than the light and medium eggs. The chick weight was 42.8, 48.4, and 54.9 g in light, medium, and heavy eggs, respectively. A percentage of 34.2, 36, and 31.6% of chicks from light, medium, and heavy eggs, hatched between 637 and 648 h, 39.6, 36.2, and 32.9% between 649 and 660 h, 26.2, 27.8, and 35.5% between 661 and 672 h of incubation, respectively. In conclusion, hatching egg quality, embryo development and yolk absorption during incubation, hatch window, and hatchability were affected by egg weight in Pekin ducks. © 2017 Poultry Science Association Inc.

  14. Effect of frozen storage on molecular weight, size distribution and conformation of gluten by SAXS and SEC-MALLS.

    PubMed

    Zhao, Lei; Li, Lin; Liu, Guo-Qin; Liu, Xing-Xun; Li, Bing

    2012-06-12

    In this study, the effects of frozen (-18 °C) storage time on molecular weight, size distribution, conformation, free amino groups and free sulfhydryl groups of gluten were studied by small-angle X-ray scattering (SAXS), multi-angle laser light scattering (MALLS) in conjunction with a size exclusion chromatography (SEC) and spectrophotometrically. The results showed that the gluten dissolved in 50 mM acetic acid appeared to be similar to quasi-spherical of the chain conformation and the slope of the conformation plot decreased during the storage. Both the molecular weight and radius of gyration of the frozen gluten decreased with the storage time showing a depolymerization in the high molecular weight fraction of gluten (10(5) Da ~ 10(9) Da). Therefore, at constant molecular weight the change of the chain conformation did not show a clear correlation with the storage time. The free amino groups content changed little and the free sulfhydryl groups content of the gluten increased from 9.8 μmol/g for the control to 12.87 μmol/g for 120-day-stored gluten, indicating that the water redistribution and ice recrystallization lead to the breakage of the disulphide bonds and may be one of the reasons for the depolymerization of gluten polymer.

  15. Phased Array Technology with Phase and Amplitude Controlled Magnetron for Microwave Power Transmission

    NASA Astrophysics Data System (ADS)

    Shinohara, N.; Matsumoto, H.

    2004-12-01

    We need a microwave power transmitter with light weight and high DC-RF conversion efficiency for an economical SSPS (Space Solar Power System). We need a several g/W for a microwave power transmission (MPT) system with a phased array with 0.0001 degree of beam control accuracy (=tan-1 (100m/36,000km)) and over 80 % of DC-RF conversion efficiency when the weight of the 1GW-class SPS is below a several thousand ton - a several tens of thousand ton. We focus a microwave tube, especially magnetron by economical reason and by the amount of mass-production because it is commonly used for microwave oven in the world. At first, we have developed a phase controlled magnetron (PCM) with different technologies from what Dr. Brown developed. Next we have developed a phase and amplitude controlled magnetron (PACM). For the PACM, we add a feedback to magnetic field of the PCM with an external coil to control and stabilize amplitude of the microwave. We succeed to develop the PACM with below 10-6 of frequency stability and within 1 degree of an error in phase and within 1% of amplitude. We can control a phase and amplitude of the PACM and we have developed a phased array the PCMs. With the PCM technology, we have developed a small light weight MPT transmitter COMET (Compact Microwave Energy Transmitter) with consideration of heat radiation for space use and with consideration of mobility to space.

  16. Design and construction of portable survey meter

    NASA Astrophysics Data System (ADS)

    Singseeta, W.; Thong-aram, D.; Pencharee, S.

    2017-09-01

    This work was aimed to design and construction of portable survey meter for radiation dose measuring. The designed system consists of 4 main parts consisting of low voltage power supply, radiation detection, radiation measurement and data display part on android phone. The test results show that the ripple voltage of low voltage power supply is less than 1%, the maximum integral counts are found to be 104 counts per second and the maximum distance of wireless commination between the server and the client is about 10 meter. It was found that the developed system had small size and light weight for portable instrument.

  17. Dynamic Strain Measured by Mach-Zehnder Interferometric Optical Fiber Sensors

    PubMed Central

    Her, Shiuh-Chuan; Yang, Chih-Min

    2012-01-01

    Optical fibers possess many advantages such as small size, light weight and immunity to electro-magnetic interference that meet the sensing requirements to a large extent. In this investigation, a Mach-Zehnder interferometric optical fiber sensor is used to measure the dynamic strain of a vibrating cantilever beam. A 3 × 3 coupler is employed to demodulate the phase shift of the Mach-Zehnder interferometer. The dynamic strain of a cantilever beam subjected to base excitation is determined by the optical fiber sensor. The experimental results are validated with the strain gauge. PMID:22737010

  18. Dynamic deformation analysis of light-weight mirror

    NASA Astrophysics Data System (ADS)

    Zhang, Yingtao; Cao, Xuedong; Kuang, Long; Yang, Wei

    2012-10-01

    In the process of optical dynamic target work, under the effort of the arm of dynamic target, the mirror needs to do circular motion, additional accelerated motion and uniform motion. The maximum acceleration is 10°/s2 and the maximum velocity is 30°/s. In this paper, we mostly analyze the dynamic deformation of a 600 mm honeycomb light-weight mirror of a certain dynamic target. Using the FEA (finite element analysis) method, first of all, we analyze the deformation of the light-weight mirror induced in gravity at different position; later, the dynamic deformation of light-weight mirror is analyzed in detailed. The analysis results indicate that, when the maximum acceleration is 10°/s2 and the maximum velocity is 30°/s, the centripetal force is 5% of the gravity at the equal mass, and the dynamic deformation of the mirror is 6.1% of the deformation induced by gravity.

  19. A Novel Sensor System for Measuring Wheel Loads of Vehicles on Highways

    PubMed Central

    Zhang, Wenbin; Suo, Chunguang; Wang, Qi

    2008-01-01

    With the development of the highway transportation and business trade, vehicle Weigh-In-Motion (WIM) technology has become a key technology for measuring traffic loads. In this paper a novel WIM system based on monitoring of pavement strain responses in rigid pavement was investigated. In this WIM system multiple low cost, light weight, small volume and high accuracy embedded concrete strain sensors were used as WIM sensors to measure rigid pavement strain responses. In order to verify the feasibility of the method, a system prototype based on multiple sensors was designed and deployed on a relatively busy freeway. Field calibration and tests were performed with known two-axle truck wheel loads and the measurement errors were calculated based on the static weights measured with a static weighbridge. This enables the weights of other vehicles to be calculated from the calibration constant. Calibration and test results for individual sensors or three-sensor fusions are both provided. Repeatability, sources of error, and weight accuracy are discussed. Successful results showed that the proposed method was feasible and proven to have a high accuracy. Furthermore, a sample mean approach using multiple fused individual sensors could provide better performance compared to individual sensors. PMID:27873952

  20. Rats fed only during the light period are resistant to stress-induced weight loss.

    PubMed

    Harris, Ruth B S; Zhou, Jun; Mitchell, Tiffany; Hebert, Sadie; Ryan, Donna H

    2002-08-01

    Repeated restraint stress (3 h/day for 3 days) causes a chronic down-regulation of body weight in rats. This study determined whether weight loss was influenced by the time of day that rats had access to food or that stress was applied. Groups of male Sprague-Dawley rats were fed a 40% kcal fat diet with food given ad libitum, only during the light phase or only during the dark phase. After 2 weeks of adaptation, rats within each feeding treatment were divided into four groups. One was exposed to repeated restraint at the start of the light phase, another was restrained at the start of the dark phase and the remaining groups were nonstressed controls for restrained rats. Body weight was significantly reduced in ad libitum- and dark-fed restrained rats, compared with nonstressed controls, from Day 2 of restraint, regardless of the time of day that they were stressed. There was no significant effect of restraint on weight change of light-fed rats. Food intake was inhibited by stress in ad libitum- and dark-fed rats, but it was not changed in light-fed rats. Serum corticosterone was increased by restraint in all rats irrespective of feeding schedule. This study demonstrates that stress-induced weight loss only occurs when rats have food available during their normal feeding period (dark phase) and is not determined by increased corticosterone release.

  1. Bayesian genome-wide association analysis for body weight in farmed Atlantic salmon (Salmo salar L.).

    PubMed

    Yoshida, G M; Lhorente, J P; Carvalheiro, R; Yáñez, J M

    2017-12-01

    We performed a genome-wide association study to detect markers associated with growth traits in Atlantic salmon. The analyzed traits included body weight at tagging (BWT) and body weight at 25 months (BW25M). Genotypes of 4662 animals were imputed from the 50K SNP chip to the 200K SNP chip using fimpute software. The markers were simultaneously modeled using Bayes C to identify genomic regions associated with the traits. We identified windows explaining a maximum of 3.71% and 3.61% of the genetic variance for BWT and BW25M respectively. We found potential candidate genes located within the top ten 1-Mb windows for BWT and BW25M. For instance, the vitronectin (VTN) gene, which has been previously reported to be associated with cell growth, was found within one of the top ten 1-Mb windows for BWT. In addition, the WNT1-inducible-signaling pathway protein 3, melanocortin 2 receptor accessory protein 2, myosin light chain kinase, transforming growth factor beta receptor type 3 and myosin light chain 1 genes, which have been reported to be associated with skeletal growth in humans, growth stimulation during the larval stage in zebrafish, body weight in pigs, feed conversion in chickens and growth rate of sheep skeletal muscle respectively, were found within some of the top ten 1-Mb windows for BW25M. These results indicate that growth traits are most likely controlled by many variants with relatively small effects in Atlantic salmon. The genomic regions associated with the traits studied here may provide further insight into the functional regions underlying growth traits in this species. © 2017 Stichting International Foundation for Animal Genetics.

  2. ARBRES: Light-Weight CW/FM SAR Sensors for Small UAVs

    PubMed Central

    Aguasca, Albert; Acevo-Herrera, Rene; Broquetas, Antoni; Mallorqui, Jordi J.; Fabregas, Xavier

    2013-01-01

    This paper describes a pair of compact CW/FM airborne SAR systems for small UAV-based operation (wingspan of 3.5 m) for low-cost testing of innovative SAR concepts. Two different SAR instruments, using the C and X bands, have been developed in the context of the ARBRES project, each of them achieving a payload weight below 5 Kg and a volume of 13.5 dm3 (sensor and controller). Every system has a dual receiving channel which allows operation in interferometric or polarimetric modes. Planar printed array antennas are used in both sensors for easy system integration and better isolation between transmitter and receiver subsystems. First experimental tests on board a 3.2 m wingspan commercial radio-controlled aircraft are presented. The SAR images of a field close to an urban area have been focused using a back-projection algorithm. Using the dual channel capability, a single pass interferogram and Digital Elevation Model (DEM) has been obtained which agrees with the scene topography. A simple Motion Compensation (MoCo) module, based on the information from an Inertial+GPS unit, has been included to compensate platform motion errors with respect to the nominal straight trajectory. PMID:23467032

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Wenwen; Wang, Weiyu; Li, Hui

    In this study, high molecular weight “comb-shaped” graft copolymers, poly(isoprene-g-styrene), with polyisoprene as the backbone and polystyrene as side chains, were synthesized via free radical emulsion polymerization by copolymerization of isoprene with a polystyrene macromonomer synthesized using anionic polymerization. A small amount of toluene was used in order to successfully disperse the macromonomer. Both a redox and thermal initiation system were used in the emulsion polymerization, and the latex particle size and distribution were investigated by dynamic light scattering. The structural characteristics of the macromonomer and comb graft copolymers were investigated through use of size exclusion chromatography, spectroscopy, microscopy, thermalmore » analysis, and rheology. While the macromonomer was successfully copolymerized to obtain the desired multigraft copolymers, small amounts of unreacted macromonomer remained in the products, reflecting its reduced reactivity due to steric effects. Nevertheless, the multigraft copolymers obtained were very high in molecular weight (5–12 × 10 5 g/mol) and up to 10 branches per chain, on average, could be incorporated. A material incorporating 29 wt% polystyrene exhibits a disordered microphase separated morphology and elastomeric properties. As a result, these materials show promise as new, highly tunable, and potentially low cost thermoplastic elastomers.« less

  4. Effects of shading on growth and development of northern red oak, black oak, black cherry, and red maple seedlings. II. biomass partitioning and prediction

    Treesearch

    Kurt W. Gottschalk

    1987-01-01

    Northern red oak, black oak, black cherry, and red maple seedlings were grown under light treatments ranging from 8 to 94% of full sunlight for 2 years. Growth was least at the lowest light level and total dry weight increased with increasing light. Total dry-weight rankings (largest to smallest) at all light levels were black cherry, northern red oak, black oak, and...

  5. Effect of light-emitting diode (LED) vs. fluorescent (FL) lighting on laying hens in aviary hen houses: Part 2 - Egg quality, shelf-life and lipid composition.

    PubMed

    Long, H; Zhao, Y; Xin, H; Hansen, H; Ning, Z; Wang, T

    2016-01-01

    In this 60-wk study, egg quality, egg shelf-life, egg cholesterol content, total yolk lipids, and yolk fatty acid composition of eggs produced by Dekalb white laying hens in commercial aviary houses with either light-emitting diode (LED) or fluorescent (FL) lighting were compared. All parameters were measured at 27, 40, and 60 wk of age, except for egg shelf-life, which was compared at 50 wk of age. The results showed that, compared to the FL regimen, the LED regimen resulted in higher egg weight, albumen height, and albumen weight at 27 wk of age, thicker shells at 40 wk of age, but lower egg weight at 60 wk of age. Egg quality change was similar between the lighting regimens during the 62-d egg storage study, indicating that LED lighting did not influence egg shelf-life. Eggs from both lighting regimens had similar cholesterol content. However, cholesterol concentration of the yolk (15.9 to 21.0 mg cholesterol/g wet weight yolk) observed in this study was higher than that of United States Department of Agriculture (USDA) database (10.85 mg/g). No significant differences in total lipids or fatty acid composition of the yolks were detected between the two lighting regimens. © 2015 Poultry Science Association Inc.

  6. General and smoking cessation weight concern in a Hispanic sample of light and intermittent smokers.

    PubMed

    Landrau-Cribbs, Erica; Cabriales, José Alonso; Cooper, Theodore V

    2015-02-01

    This study assessed general and cessation related weight concerns in a Hispanic sample of light (≤10 cigarettes per day) and intermittent (non-daily smoking) smokers (LITS) participating in a brief smoking cessation intervention. Three hundred and fifty-four Hispanic LITS (Mage=34.2, SD=14; 51.1% male; 57.9% Mexican American; 59.0% daily light, 41.0% intermittent) completed baseline measures assessing demographics, tobacco use/history, stage of change (SOC), general weight concern, and cessation related weight concern. Three multiple logistic regression models examined potential predictors (i.e., age, gender, SOC, cigarettes per month, smoking status [daily vs non-daily], weight, cessation related weight concern, general weight concern) of general weight concern, cessation related weight concern, and past 30day abstinence (controlling for the intervention). Study results indicated that a majority of participants reported general weight concern (59.6%), and slightly more than a third (35.6%) reported post cessation weight gain concern (mean and median weight tolerated before relapse were within the 10-12lb range). Lower weight and endorsing general weight concern were associated with cessation related weight concern. Female gender, higher weight, and endorsing cessation related weight concern were associated with general weight concern. Monthly cigarette use was associated with smoking cessation at the three-month follow-up. The results indicate a substantial prevalence of general weight concern and non-trivial rates of cessation related weight concern in Hispanic LITS attempting to quit, and greater success in quitting among those who reported lower rates of cigarettes smoked per month. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Light-weighting, polishing and bonding for the SEOSAT/Ingenio telescope mirrors

    NASA Astrophysics Data System (ADS)

    Harel, Emmanuelle

    2017-11-01

    Sagem presents its recent developments in light-weighting, polishing, bonding and testing of Zerodur space mirrors equipped with pads and fixation devices. The presentation is based on Sagem's recent successful project for the SEOSAT/Ingenio satellite.

  8. Weight management for adolescents with intellectual and developmental disabilities: Rationale and design for an 18month randomized trial.

    PubMed

    Donnelly, J E; Ptomey, L T; Goetz, J R; Sullivan, D K; Gibson, C A; Greene, J L; Lee, R H; Mayo, M S; Honas, J J; Washburn, R A

    2016-11-01

    Adolescents with intellectual and developmental disabilities (IDD) are an underserved group in need of weight management. However, information regarding effective weight management for this group is limited, and is based primarily on results from small, non-powered, non-randomized trials that were not conducted in accordance with current weight management guidelines. Additionally, the comparative effectiveness of emerging dietary approaches, such as portion-controlled meals (PCMs) or program delivery strategies such as video chat using tablet computers have not been evaluated. Therefore, we will conduct an 18month trial to compare weight loss (6months) and maintenance (7-18months) in 123 overweight/obese adolescents with mild to moderate IDD, and a parent, randomized to a weight management intervention delivered remotely using FaceTime™ on an iPad using either a conventional meal plan diet (RD/CD) or a Stop Light diet enhanced with PCMs (RD/eSLD), or conventional diet delivered during face-to-face home visits (FTF/CD). This design will provide an adequately powered comparison of both diet (CD vs. eSLD) and delivery strategy (FTF vs. RD). Exploratory analyses will examine the influence of behavioral session attendance, compliance with recommendations for diet (energy intake), physical activity (min/day), self-monitoring of diet and physical activity, medications, and parental variables including diet quality, physical activity, baseline weight, weight change, and beliefs and attitudes regarding diet and physical activity on both weight loss and maintenance. We will also complete a cost and contingent valuation analysis to compare costs between RD and FTF delivery. Copyright © 2016. Published by Elsevier Inc.

  9. Smith machine counterbalance system affects measures of maximal bench press throw performance.

    PubMed

    Vingren, Jakob L; Buddhadev, Harsh H; Hill, David W

    2011-07-01

    Equipment with counterbalance weight systems is commonly used for the assessment of performance in explosive resistance exercise movements, but it is not known if such systems affect performance measures. The purpose of this study was to determine the effect of using a counterbalance weight system on measures of smith machine bench press throw performance. Ten men and 14 women (mean ± SD: age, 25 ± 4 years; height, 173 ± 10 cm; weight, 77.7 ± 18.3 kg) completed maximal smith machine bench press throws under 4 different conditions (2 × 2; counterbalance × load): with or without a counterbalance weight system and using 'light' or 'moderate' net barbell loads. Performance variables (peak force, peak velocity, and peak power) were measured using a linear accelerometer attached to the barbell. The counterbalance weight system resulted in significant (p < 0.001) reductions in measures of peak force (mean difference ± standard error: light: -112 ± 20 N; moderate: -140 ± 23 N), peak velocity (light: -0.49 ± 0.10 m·s; moderate: -0.33 ± 0.07 m·s), and peak power (light: -220 ± 43 W; moderate: -143 ± 28 W) compared with no counterbalance system for both load conditions. Load condition did not affect absolute or percentage reductions from the counterbalance weight system for any variable. In conclusion, the use of a counterbalance weight system reduces accelerometer-based performance measures for the bench press throw exercise at light and moderate loads. This reduction in measures is likely because of an increase in the external resistance during the movement, which results in a discrepancy between the manually input and the actual value for external load. A counterbalance weight system should not be used when measuring performance in explosive resistance exercises with an accelerometer.

  10. Determination of the absolute molecular weight averages and molecular weight distributions of alginates used as ice cream stabilizers by using multiangle laser light scattering measurements.

    PubMed

    Turquois, T; Gloria, H

    2000-11-01

    High-performance size exclusion chromatography with multiangle laser light scattering detection (HPSEC-MALLS) was used for characterizing complete molecular weight distributions for a range of commercial alginates used as ice cream stabilizers. For the samples investigated, molecular weight averages were found to vary between 115 000 and 321 700 g/mol and polydispersity indexes varied from 1. 53 to 3.25. These samples displayed a high content of low molecular weights. Thus, the weight percentage of material below 100 000 g/mol ranged between 6.9 and 54.4%.

  11. Fiber-Optic Current Sensor Validation with Triggered Lightning Measurements

    NASA Technical Reports Server (NTRS)

    Nguyen, Truong X.; Ely, Jay J.; Szatkowski, George N.; Mata, Carlos T.; Mata, Angel G.; Snyder, Gary P.

    2013-01-01

    A fiber optic current sensor based on the Faraday Effect is developed that is highly suitable for aircraft installation and can measure total current enclosed in a fiber loop down to DC. Other attributes include being small, light-weight, non-conducting, safe from electromagnetic interference, and free of hysteresis and saturation. The Faraday Effect causes light polarization to rotate when exposed to a magnetic field in the direction of light propagation. Measuring the induced light polarization rotation in fiber loops yields the total current enclosed. Two sensor systems were constructed and installed at Camp Blanding, Florida, measuring rocket-triggered lightning. The systems were similar in design but with different laser wavelengths, sensitivities and ranges. Results are compared to a shunt resistor as reference. The 850nm wavelength system tested in summer 2011 showed good result comparison early. However, later results showed gradual amplitude increase with time, attributed to corroded connections affecting the 50-ohm output termination. The 1550nm system also yielded good results in the summer 2012. The successful measurements demonstrate the fiber optic sensor's accuracies in capturing real lightning currents, and represent an important step toward future aircraft installation.

  12. Design of Smart Multi-Functional Integrated Aviation Photoelectric Payload

    NASA Astrophysics Data System (ADS)

    Zhang, X.

    2018-04-01

    To coordinate with the small UAV at reconnaissance mission, we've developed a smart multi-functional integrated aviation photoelectric payload. The payload weighs only 1kg, and has a two-axis stabilized platform with visible task payload, infrared task payload, laser pointers and video tracker. The photoelectric payload could complete the reconnaissance tasks above the target area (including visible and infrared). Because of its light weight, small size, full-featured, high integrated, the constraints of the UAV platform carrying the payload will be reduced a lot, which helps the payload suit for more extensive using occasions. So all users of this type of smart multi-functional integrated aviation photoelectric payload will do better works on completion of the ground to better pinpoint targets, artillery calibration, assessment of observe strike damage, customs officials and other tasks.

  13. Towards GPS Surface Reflection Remote Sensing of Sea Ice Conditions

    NASA Technical Reports Server (NTRS)

    Komjathy, A.; Maslanik, J. A.; Zavorotny, V. U.; Axelrad, P.; Katzberg, S. J.

    2000-01-01

    This paper describes the research to extend the application of Global Positioning System (GPS) signal reflections, received by airborne instruments, to cryospheric remote sensing. The characteristics of the GPS signals and equipment afford the possibility of new measurements not possible with existing radar and passive microwave systems. In particular, the GPS receiving systems are small and light-weight, and as such are particularly well suited to be deployed on small aircraft or satellite platforms with minimal impact. Our preliminary models and experimental results indicate that reflected GPS signals have potential to provide information on the presence and condition of sea and fresh-water ice as well as the freeze/thaw state of frozen ground. In this paper we show results from aircraft experiments over the ice pack near Barrow, Alaska suggesting correlation between forward scattered GPS returns and RADARSAT backscattered signals.

  14. Research and implementation of a new 6-DOF light-weight robot

    NASA Astrophysics Data System (ADS)

    Tao, Zihang; Zhang, Tao; Qi, Mingzhong; Ji, Junhui

    2017-06-01

    Traditional industrial robots have some weaknesses such as low payload-weight, high power consumption and high cost. These drawbacks limit their applications in such areas, special application, service and surgical robots. To improve these shortcomings, a new kind 6-DOF light-weight robot was designed based on modular joints and modular construction. This paper discusses the general requirements of the light-weight robots. Based on these requirements the novel robot is designed. The new robot is described from two aspects, mechanical design and control system. A prototype robot had developed and a joint performance test platform had designed. Position and velocity tests had conducted to evaluate the performance of the prototype robot. Test results showed that the prototype worked well.

  15. Moderate Versus Light Pressure Massage Therapy Leads to Greater Weight Gain in Preterm Infants

    PubMed Central

    Field, Tiffany; Diego, Miguel A.; Hernandez-Reif, Maria; Deeds, Osvelia; Figuereido, Barbara

    2007-01-01

    Sixty-eight preterm infants (M GA=3Owks.) were randomly assigned to a moderate or to a light pressure massage therapy group to receive 15 massages 3 times per day for 5 days. Behavior state, stress behaviors and heart rate were recorded for 15 minutes before and during the first 15-minute therapy session. Weight gain was recorded over the 5 day therapy period. The moderate versus light pressure massage group gained significantly more weight per day. During the behavior observations the moderate versus light pressure massage group showed significantly lower increases from the pre-session to the session recording on: 1) active sleep; 2) fussing; 3) crying; 4) movement; and 5) stress behavior (hiccupping). They also showed a smaller decrease in deep sleep, a greater decrease in heart rate and a greater increase in vagal tone. Thus, the moderate pressure massage therapy group appeared to be more relaxed and less aroused than the light pressure massage group which may have contributed to the greater weight gain of the moderate pressure massage therapy group. PMID:17138310

  16. Moderate versus light pressure massage therapy leads to greater weight gain in preterm infants.

    PubMed

    Field, Tiffany; Diego, Miguel A; Hernandez-Reif, Maria; Deeds, Osvelia; Figuereido, Barbara

    2006-12-01

    Sixty-eight preterm infants (M GA=30 weeks) were randomly assigned to a moderate or to a light pressure massage therapy group to receive 15 massages three times per day for 5 days. Behavior state, stress behaviors and heart rate were recorded for 15min before and during the first 15-min therapy session. Weight gain was recorded over the 5-day therapy period. The moderate versus light pressure massage group gained significantly more weight per day. During the behavior observations the moderate versus light pressure massage group showed significantly lower increases from the pre-session to the session recording on: (1) active sleep; (2) fussing; (3) crying; (4) movement; and (5) stress behavior (hiccupping). They also showed a smaller decrease in deep sleep, a greater decrease in heart rate and a greater increase in vagal tone. Thus, the moderate pressure massage therapy group appeared to be more relaxed and less aroused than the light pressure massage group which may have contributed to the greater weight gain of the moderate pressure massage therapy group.

  17. A label-free fiber-optic Turbidity Affinity Sensor (TAS) for continuous glucose monitoring.

    PubMed

    Dutt-Ballerstadt, Ralph; Evans, Colton; Pillai, Arun P; Gowda, Ashok

    2014-11-15

    In this paper, we describe the concept of a novel implantable fiber-optic Turbidity Affinity Sensor (TAS) and report on the findings of its in-vitro performance for continuous glucose monitoring. The sensing mechanism of the TAS is based on glucose-specific changes in light scattering (turbidity) of a hydrogel suspension consisting of small particles made of crosslinked dextran (Sephadex G100), and a glucose- and mannose-specific binding protein - Concanavalin A (ConA). The binding of ConA to Sephadex particles results in a significant turbidity increase that is much greater than the turbidity contribution by the individual components. The turbidity of the TAS was measured by determining the intensity of light passing through the suspension enclosed within a small semi-permeable hollow fiber (OD: 220 μm, membrane thickness: 20 μm, molecular weight cut-off: 10 kDa) using fiber optics. The intensity of measured light of the TAS was proportional to the glucose concentration over the concentration range from 50mg/dL to 400mg/dL in PBS and whole blood at 37°C (R>0.96). The response time was approximately 4 min. The stability of the glucose response of the TAS decreased only slightly (by 20%) over an 8-day study period at 37°C. In conclusion, this study demonstrated proof-of-concept of the TAS for interstitial glucose monitoring. Due to the large signal amplitude of the turbidity change, and the lack of need for wavelength-specific emission and excitation filters, a very small, robust and compact TAS device with an extremely short optical pathlength could be feasibly designed and implemented for in-vivo glucose monitoring in people with diabetes. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Study of sample drilling techniques for Mars sample return missions

    NASA Technical Reports Server (NTRS)

    Mitchell, D. C.; Harris, P. T.

    1980-01-01

    To demonstrate the feasibility of acquiring various surface samples for a Mars sample return mission the following tasks were performed: (1) design of a Mars rover-mounted drill system capable of acquiring crystalline rock cores; prediction of performance, mass, and power requirements for various size systems, and the generation of engineering drawings; (2) performance of simulated permafrost coring tests using a residual Apollo lunar surface drill, (3) design of a rock breaker system which can be used to produce small samples of rock chips from rocks which are too large to return to Earth, but too small to be cored with the Rover-mounted drill; (4)design of sample containers for the selected regolith cores, rock cores, and small particulate or rock samples; and (5) design of sample handling and transfer techniques which will be required through all phase of sample acquisition, processing, and stowage on-board the Earth return vehicle. A preliminary design of a light-weight Rover-mounted sampling scoop was also developed.

  19. Data Base for Light-Weight Automotive Diesel Power Plants : Volume 3. Miscellaneous Data.

    DOT National Transportation Integrated Search

    1979-12-01

    The effects of fuel economy, emissions, passenger car safety and other variables due to the installation of light-weight Diesel powerplants were studied. Experimental data was obtained on naturally aspirated and turbocharged Diesel engines installed ...

  20. Data Base for Light-Weight Automotive Diesel Power Plants. Volume 2: Discussion and Results.

    DOT National Transportation Integrated Search

    1979-12-01

    The effects on fuel economy, emissions, passenger car safety and other variables due to the installation of light-weight Diesel powerplants were studied. Experimental data was obtained on naturally aspirated and turbocharged Diesel engines installed ...

  1. Data Base for Light-Weight Automotive Diesel Power Plants: Volume 1. Executive Summary.

    DOT National Transportation Integrated Search

    1979-12-01

    The effects on fuel economy, emissions, passenger car safety and other variables due to the installation of light-weight Diesel powerplants were studied. Experimental data was obtained on naturally aspirated and turbocharged Diesel engines installed ...

  2. Production of ELZM mirrors: performance coupled with attractive schedule, cost, and risk factors

    NASA Astrophysics Data System (ADS)

    Leys, Antoine; Hull, Tony; Westerhoff, Thomas

    2016-08-01

    Extreme light weighted ZERODUR Mirrors (ELZM) have been developed to exploit the superb thermal characteristics of ZERODUR. Coupled with up to date mechanical and optical fabrication methods this becomes an attractive technical approach. However the process of making mirror substrates has demonstrated to be unusually rapid and especially cost-effective. ELZM is aimed at the knee of the cost as a function of light weighting curve. ELZM mirrors are available at 88% light weighted. Together with their low risk, low cost production methods, this is presented as a strong option for NASA Explorer and Probe class missions.

  3. Interfacial thiol-ene photoclick reactions for forming multilayer hydrogels.

    PubMed

    Shih, Han; Fraser, Andrew K; Lin, Chien-Chi

    2013-03-13

    Interfacial visible light-mediated thiol-ene photoclick reactions were developed for preparing step-growth hydrogels with multilayer structures. The effect of a noncleavage type photoinitiator eosin-Y on visible-light-mediated thiol-ene photopolymerization was first characterized using in situ photorheometry, gel fraction, and equilibrium swelling ratio. Next, spectrophotometric properties of eosin-Y in the presence of various relevant macromer species were evaluated using ultraviolet-visible light (UV-vis) spectrometry. It was determined that eosin-Y was able to reinitiate the thiol-ene photoclick reaction, even after light exposure. Because of its small molecular weight, most eosin-Y molecules readily leached out from the hydrogels. The diffusion of residual eosin-Y from preformed hydrogels was exploited for fabricating multilayer step-growth hydrogels. Interfacial hydrogel coating was formed via the same visible-light-mediated gelation mechanism without adding fresh initiator. The thickness of the thiol-ene gel coating could be easily controlled by adjusting visible light exposure time, eosin-Y concentration initially loaded in the core gel, or macromer concentration in the coating solution. The major benefits of this interfacial thiol-ene coating system include its simplicity and cytocompatibility. The formation of thiol-ene hydrogels and coatings neither requires nor generates any cytotoxic components. This new gelation chemistry may have great utilities in controlled release of multiple sensitive growth factors and encapsulation of multiple cell types for tissue regeneration.

  4. Crop yield and light/energy efficiency in a closed ecological system: Laboratory Biosphere experiments with wheat and sweet potato.

    PubMed

    Nelson, M; Dempster, W F; Silverstone, S; Alling, A; Allen, J P; van Thillo, M

    2005-01-01

    Two crop growth experiments in the soil-based closed ecological facility, Laboratory Biosphere, were conducted from 2003 to 2004 with candidate space life support crops. Apogee wheat (Utah State University variety) was grown, planted at two densities, 400 and 800 seeds m-2. The lighting regime for the wheat crop was 16 h of light-8 h dark at a total light intensity of around 840 micromoles m-2 s-1 and 48.4 mol m-2 d-1 over 84 days. Average biomass was 1395 g m-2, 16.0 g m-2 d-1 and average seed production was 689 g m-2 and 7.9 g m-2 d-1. The less densely planted side was more productive than the denser planting, with 1634 g m-2 and 18.8 g m-2 d-1 of biomass vs. 1156 g m-2 and 13.3 g m-2 d-1; and a seed harvest of 812.3 g m-2 and 9.3 g m-2 d-1 vs. 566.5 g m-2 and 6.5 g m-2 d-1. Harvest index was 0.49 for the wheat crop. The experiment with sweet potato used TU-82-155 a compact variety developed at Tuskegee University. Light during the sweet potato experiment, on a 18 h on/6 h dark cycle, totaled 5568 total moles of light per square meter in 126 days for the sweet potatoes, or an average of 44.2 mol m-2 d-1. Temperature regime was 28 +/- 3 degrees C day/22 +/- 4 degrees C night. Sweet potato tuber yield was 39.7 kg wet weight, or an average of 7.4 kg m-2, and 7.7 kg dry weight of tubers since dry weight was about 18.6% wet weight. Average per day production was 58.7 g m-2 d-1 wet weight and 11.3 g m-2 d-1. For the wheat, average light efficiency was 0.34 g biomass per mole, and 0.17 g seed per mole. The best area of wheat had an efficiency of light utilization of 0.51 g biomass per mole and 0.22 g seed per mole. For the sweet potato crop, light efficiency per tuber wet weight was 1.33 g mol-1 and 0.34 g dry weight of tuber per mole of light. The best area of tuber production had 1.77 g mol-1 wet weight and 0.34 g mol-1 of light dry weight. The Laboratory Biosphere experiment's light efficiency was somewhat higher than the USU field results but somewhat below greenhouse trials at comparable light levels, and the best portion of the crop at 0.22 g mol-1 was in-between those values. Sweet potato production was overall close to 50% higher than trials using hydroponic methods with TU-82-155 at NASA JSC. Compared to projected yields for the Mars on Earth life support system, these wheat yields were about 15% higher, and the sweet potato yields averaged over 80% higher. c2005 Published by Elsevier Ltd on behalf of COSPAR.

  5. Evaluation of inorganic and organic light-emitting diode displays for signage application

    NASA Astrophysics Data System (ADS)

    Sharma, Pratibha; Kwok, Harry

    2006-08-01

    High-brightness, inorganic light-emitting diodes (LEDs) have been successfully utilized for edge-lighting of large displays for signage. Further interest in solid-state lighting technology has been fueled with the emergence of small molecule and polymer-based organic light-emitting diodes (OLEDs). In this paper, edgelit inorganic LED-based displays and state-of-the-art OLED-based displays are evaluated on the basis of electrical and photometric measurements. The reference size for a signage system is assumed to be 600 mm x 600mm based on the industrial usage. With the availability of high power light-emitting diodes, it is possible to develop edgelit signage systems of the standard size. These displays possess an efficacy of 18 lm/W. Although, these displays are environmentally friendly and efficient, they suffer from some inherent limitations. Homogeneity of displays, which is a prime requirement for illuminated signs, is not accomplished. A standard deviation of 3.12 lux is observed between the illuminance values on the surface of the display. In order to distribute light effectively, reflective gratings are employed. Reflective gratings aid in reducing the problem but fail to eliminate it. In addition, the overall cost of signage is increased by 50% with the use of these additional components. This problem can be overcome by the use of a distributed source of light. Hence, the organic-LEDs are considered as a possible contender. In this paper, we experimentally determine the feasibility of using OLEDs for signage applications and compare their performance with inorganic LEDs. Passive matrix, small-molecule based, commercially available OLEDs is used. Design techniques for implementation of displays using organic LEDs are also discussed. It is determined that tiled displays based on organic LEDs possess better uniformity than the inorganic LED-based displays. However, the currently available OLEDs have lower light-conversion efficiency and higher costs than the conventional, inorganic LEDs. But, signage panels based on OLEDs can be made cheaper by avoiding the use of acrylic sheet and reflective gratings. Moreover, the distributed light output and light weight of OLEDs and the potential to be built inexpensively on flexible substrates can make OLEDs more beneficial for future signage applications than the inorganic LEDs.

  6. The theoretical simulation on electrostatic distribution of 1st proximity region in proximity focusing low-light-level image intensifier

    NASA Astrophysics Data System (ADS)

    Zhang, Liandong; Bai, Xiaofeng; Song, De; Fu, Shencheng; Li, Ye; Duanmu, Qingduo

    2015-03-01

    Low-light-level night vision technology is magnifying low light level signal large enough to be seen by naked eye, which uses the photons - photoelectron as information carrier. Until the micro-channel plate was invented, it has been possibility for the realization of high performance and miniaturization of low-light-level night vision device. The device is double-proximity focusing low-light-level image intensifier which places a micro-channel plate close to photocathode and phosphor screen. The advantages of proximity focusing low-light-level night vision are small size, light weight, small power consumption, no distortion, fast response speed, wide dynamic range and so on. It is placed parallel to each other for Micro-channel plate (both sides of it with metal electrode), the photocathode and the phosphor screen are placed parallel to each other. The voltage is applied between photocathode and the input of micro-channel plate when image intensifier works. The emission electron excited by photo on the photocathode move towards to micro-channel plate under the electric field in 1st proximity focusing region, and then it is multiplied through the micro-channel. The movement locus of emission electrons can be calculated and simulated when the distributions of electrostatic field equipotential lines are determined in the 1st proximity focusing region. Furthermore the resolution of image tube can be determined. However the distributions of electrostatic fields and equipotential lines are complex due to a lot of micro-channel existing in the micro channel plate. This paper simulates electrostatic distribution of 1st proximity region in double-proximity focusing low-light-level image intensifier with the finite element simulation analysis software Ansoft maxwell 3D. The electrostatic field distributions of 1st proximity region are compared when the micro-channel plates' pore size, spacing and inclination angle ranged. We believe that the electron beam movement trajectory in 1st proximity region will be better simulated when the electronic electrostatic fields are simulated.

  7. Preparation of Robust Metal-Free Magnetic Nanoemulsions Encapsulating Low-Molecular-Weight Nitroxide Radicals and Hydrophobic Drugs Directed Toward MRI-Visible Targeted Delivery.

    PubMed

    Nagura, Kota; Takemoto, Yusa; Moronaga, Satori; Uchida, Yoshiaki; Shimono, Satoshi; Shiino, Akihiko; Tanigaki, Kenji; Amano, Tsukuru; Yoshino, Fumi; Noda, Yohei; Koizumi, Satoshi; Komatsu, Naoki; Kato, Tatsuhisa; Yamauchi, Jun; Tamura, Rui

    2017-11-07

    With a view to developing a theranostic nanomedicine for targeted drug delivery systems visible by magnetic resonance (MR) imaging, robust metal-free magnetic nanoemulsions (mean particle size less than 20 nm) consisting of a biocompatible surfactant and hydrophobic, low molecular weight 2,2,5-trimethyl-5-(4-alkoxy)phenylpyrrolidine-N-oxyl radicals were prepared in pH 7.4 phosphate-buffered saline (PBS). The structure of the nanoemulsions was characterized by electron paramagnetic resonance spectroscopy, and dynamic light scattering and small-angle neutron-scattering measurements. The nanoemulsions showed high colloidal stability, low cytotoxicity, enough reduction resistance to excess ascorbic acid, and sufficient contrast enhancement in the proton longitudinal relaxation time (T 1 ) weighted MR images in PBS in vitro (and preliminarily in vivo). Furthermore, the hydrophobic anticancer drug paclitaxel could be encapsulated inside the nanoparticles, and the resulting paclitaxel-loaded nanoemulsions were efficiently incorporated into HeLa cells to suppress cell growth. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Effects of lighting and air-conditioning systems on growth weight and functional composition of frill-lettuce produced in plant factory

    NASA Astrophysics Data System (ADS)

    Yoshida, Atsumasa; Okamura, Nobuya; Furukawa, Hajime; Myojin, Chiho; Moriuchi, Koji; Kinoshita, Shinichi

    2017-06-01

    The aim of the present study was to develop optimal air-conditioning systems for plant factories. To verify the effect of particular air-conditioning and lighting systems, cultivation experiments were performed with frill-lettuce for two weeks. In the present study, the relationship between the cultivation condition, the yield (i.e., increase in edible portion weight), and the functional components were discussed. Based on the measured data, increased photosynthetic photon flux density increased antioxidative activity and edible portion weight, possibly because high light intensities are stressful for frill lettuce. Antioxidative activity also increased under conditions of low CO2 concentration, weak and strong winds, and high air temperature because these conditions became stresses for the plants. However, a decrease in edible portion weight was observed under these conditions, implying there is a negative correlation between antioxidative activity and edible portion weight.

  9. Variability of uterine blood flow in lactating cows during the second half of gestation.

    PubMed

    Herzog, Kathrin; Koerte, Juliane; Flachowsky, Gerhard; Bollwein, Heinrich

    2011-06-01

    The main goal of the present study was to measure uterine blood flow volume (BFV) in the second half of gestation in lactating German Holstein cows. Furthermore, it was investigated, if there are individual variations in uterine blood flow and correlations between uterine blood flow and maternal weight and the birth weight of the calf. Forty-four cows were examined via color Doppler sonography in gestation weeks (GW) 21, 25, 29, 33, 37 and 39. The cows were allocated in groups based on the following variables: body weight (light ≤ 575 kg, heavy > 575 kg) and birth weight of the calf (light ≤ 42 kg, heavy > 42 kg). The BFV was measured via transrectal Doppler sonography of both uterine arteries. There was a linear increase in uterine BFV throughout the study period from 3053 ± 1143 ml/min to 16912 ± 5793 ml/min. Variation coefficients for inter-individual variations ranged from 34 to 37%. There was a moderate correlation between uterine BFV and birth weight of the calf in weeks 21 to 37 (0.30 ≤ r < 0.49; P < 0.05) and a good correlation in week 39 (r = 0.60; P < 0.0001). Uterine BFV in week 21 was significantly (P < 0.01) higher in heavy cows (3394 ± 1119 ml/min) than in light cows (2658 ± 1064 ml/min). Compared with light cows, the increase in uterine BFV was 32% higher in heavy cows during the study period. In week 21, there was no difference (P > 0.05) in uterine BFV between cows carrying a heavy calf (3351 ± 1130 ml/min) and those carrying a light calf (2796 ± 1115 ml/min). Thereafter, the increase of BFV was 43% higher in cows with a heavy calf than in those carrying a light calf. Cows with different body weights, but same birth weight of calf showed no differences (P > 0.05) in the increase of BFV, while in cows with the same body weight the rise in BFV was higher (P < 0.05) in those cows producing a heavy calf compared to cows carrying calves with light birth weights. In conclusion, there was a linear increase in uterine BFV in lactating Holstein cows during the second half of pregnancy with marked individual variations. Differences in the rise of BFV were more caused by the fetus than by body weight of cows. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. Influence of light exposure at nighttime on sleep development and body growth of preterm infants

    PubMed Central

    Kaneshi, Yosuke; Ohta, Hidenobu; Morioka, Keita; Hayasaka, Itaru; Uzuki, Yutaka; Akimoto, Takuma; Moriichi, Akinori; Nakagawa, Machiko; Oishi, Yoshihisa; Wakamatsu, Hisanori; Honma, Naoki; Suma, Hiroki; Sakashita, Ryuichi; Tsujimura, Sei-ichi; Higuchi, Shigekazu; Shimokawara, Miyuki; Cho, Kazutoshi; Minakami, Hisanori

    2016-01-01

    Previous studies have demonstrated that a light-dark cycle has promoted better sleep development and weight gain in preterm infants than constant light or constant darkness. However, it was unknown whether brief light exposure at night for medical treatment and nursing care would compromise the benefits brought about by such a light-dark cycle. To examine such possibility, we developed a special red LED light with a wavelength of >675 nm which preterm infants cannot perceive. Preterm infants born at <36 weeks’ gestational age were randomly assigned for periodic exposure to either white or red LED light at night in a light-dark cycle after transfer from the Neonatal Intensive Care Unit to the Growing Care Unit, used for supporting infants as they mature. Activity, nighttime crying and body weight were continuously monitored from enrolment until discharge. No significant difference in rest-activity patterns, nighttime crying, or weight gain was observed between control and experimental groups. The data indicate that nursing care conducted at 3 to 4-hour intervals exposing infants to light for <15 minutes does not prevent the infants from developing circadian rest-activity patterns, or proper body growth as long as the infants are exposed to regular light-dark cycles. PMID:26877166

  11. In vivo light dosimetry for pleural PDT

    NASA Astrophysics Data System (ADS)

    Dimofte, Andreea; Zhu, Timothy C.; Finlay, Jarod C.; Culligan, Melissa; Edmonds, Christine E.; Friedberg, Joseph S.; Cengel, Keith; Hahn, Stephen M.

    2009-02-01

    In-vivo light Dosimetry for patients undergoing photodynamic therapy (PDT) is one of the important dosimetry quantities critical for predicting PDT outcome. This study examines the light fluence (rate) delivered to patients undergoing pleural PDT as a function of treatment time, treatment volume and surface area, and its accuracy as a function of the calibration accuracies of each isotropic detector and the calibration integrating sphere. The patients studied here were enrolled in Phase II clinical trial of Photofrin-mediated PDT for the treatment of non-small cell lung cancer with pleural effusion. The ages of the patients studied varied from 34 to 69 year old. All patients were administered 2mg per kg body weight Photoprin 24 hours before the surgery. Patients undergoing photodynamic therapy (PDT) are treated with laser light with a light fluence of 60 J/cm^2 at 630nm. Fluence rate (mW/cm^2) and cumulative fluence (J/cm^2) was monitored at 7 different sites during the entire light treatment delivery. Isotropic detectors were used for in-vivo light dosimetry. The anisotropy of each isotropic detector was found to be within 30%. The mean fluence rate delivery varied from 37.84 to 94.05 mW/cm^2 and treatment time varied from 1762 to 5232s. We have established a correlation between the treatment time and the treatment volume. The results are discussed using an integrating sphere theory and the measured tissue optical properties. The result can be used as a clinical guideline for future pleural PDT treatment.

  12. NASA-UVA light aerospace alloy and structures technology program

    NASA Technical Reports Server (NTRS)

    Gangloff, Richard P.; Haviland, John K.; Herakovich, Carl T.; Pilkey, Walter D.; Pindera, Marek-Jerzy; Thornton, Earl A.; Stoner, Glenn E.; Swanson, Robert E.; Wawner, Franklin E., Jr.; Wert, John A.

    1989-01-01

    The report on progress achieved in accomplishing of the NASA-UVA Light Aerospace Alloy and Structures Technology Program is presented. The objective is to conduct interdisciplinary graduate student research on the performance of next generation, light weight aerospace alloys and associated thermal gradient structures in close collaboration with researchers. The efforts will produce basic understanding of material behavior, new monolithic and composite alloys, processing methods, solid and fluid mechanics analyses, measurement advances, and a pool of educated graduate students. The presented accomplishments include: research on corrosion fatigue of Al-Li-Cu alloy 2090; research on the strengthening effect of small In additions to Al-Li-Cu alloys; research on localized corrosion of Al-Li alloys; research on stress corrosion cracking of Al-Li-Cu alloys; research on fiber-matrix reaction studies (Ti-1100 and Ti-15-3 matrices containing SCS-6, SCS-9, and SCS-10 fibers); and research on methods for quantifying non-random particle distribution in materials that has led to generation of a set of computer programs that can detect and characterize clusters in particles.

  13. Preliminary Investigation of Impact on Multiple-Sheet Structures and an Evaluation of the Meteoroid Hazard to Space Vehicles

    NASA Technical Reports Server (NTRS)

    Nysmith, C. Robert; Summers, James L.

    1961-01-01

    Small pyrex glass spheres, representative of stoney meteoroids, were fired into 2024-T3 aluminum alclad multiple-sheet structures at velocities to 11,000 feet per second to evaluate the effectiveness of multisheet hull construction as a means of increasing the resistance of a spacecraft to meteoroid penetrations. The results of these tests indicate that increasing the number of sheets in a structure while keeping the total sheet thickness constant and increasing the spacing between sheets both tend to increase the penetration resistance of a structure of constant weight per unit area. In addition, filling the space between the sheets with a light filler material was found to substantially increase structure penetration resistance with a small increase in weight. An evaluation of the meteoroid hazard to space vehicles is presented in the form of an illustrative-example for two specific lunar mission vehicles, a single-sheet, monocoque hull vehicle and a glass-wool filled, double-sheet hull vehicle. The evaluation is presented in terms of the "best" and the "worst" conditions that might be expected as determined from astronomical and satellite measurements, high-speed impact data, and hypothesized meteoroid structures and compositions. It was observed that the vehicle flight time without penetration can be increased significantly by use of multiple-sheet rather than single-sheet hull construction with no increase in hull weight. Nevertheless, it is evident that a meteoroid hazard exists, even for the vehicle with the selected multiple-sheet hull.

  14. Effects of light intensity and quality on phycobiliprotein accumulation in the cyanobacterium Nostoc sphaeroides Kützing.

    PubMed

    Ma, Rui; Lu, Fan; Bi, Yonghong; Hu, Zhengyu

    2015-08-01

    To assess the effects of light intensity and quality on the growth and phycobiliproteins (PBP) accumulation in Nostoc sphaeroides Kützing (N. sphaeroides). Dry weights, dry matter, protein, chlorophyll and PBP contents were higher under 90 μmol m(-2) s(-1) than under other intensities (both higher and lower). Phycocyanin and allophycocyanin increased with light intensity while phycoerythrin decreased. Fresh weights, protein and PBP contents increased at the highest rates under blue light. Red light resulted in higher values of dry matter, phycocyanin and chlorophyll a. White light at 90 μmol m(-2) s(-1) or blue light 30 μmol m(-2) s(-1) were optimal for the growth and phycobiliprotein accumulation in N. sphaeroides.

  15. Light Weight Silicon Mirrors for Space Instrumentation

    NASA Technical Reports Server (NTRS)

    Bly, Vincent T.; Hill, Peter C.; Hagopian, John G.; Strojay, Carl R.; Miller, Timothy

    2012-01-01

    Each mirror is a monolithic structure from a single crystal of silicon. The mirrors are light weighted after the optical surface is ground and polished. Mirrors made during the initial phase of this work were typically 1/50 lambda or better (RMS at 633 n m)

  16. The influence of non-ionic radiation on the chicken hatching.

    PubMed

    Veterány, Ladislav; Toman, Robert; Jedlicka, Jaroslav

    2002-11-01

    The study considers the influence of non-ionic radiation (white and monochromatic light) on the hatching of the Hampshire breed chickens. The chicken embryos were most sensitive to the white light (El), reaching the hatching time of 503.63 +/- 3.17 h, the hatchability of 95.12 +/- 3.72% and an average weight of incubated chickens 46.83 +/- 2.82 g. Of the monochromatic lights, the chicken embryos were most sensitive to yellow and green lights (E5, E4) with the hatching time of 505.22 +/- 4.03 and 507.14 +/- 3.95 h, respectively, the hatchability of 94.89 +/- 3.02 and 94.47 +/- 2.93%, respectively and the average weight of incubated chickens 45.72 +/- 1.93 and 45.05 +/- 2.66 g, respectively. The least reaction of chicken was observed with violet light (E2) with the hatching time of 510.04+/- 1.97 h, hatchability of 90.81 +/- 4.05% and the average weight of incubated chickens 42.02 +/- 3.72 g. The effect of violet light brings the same results as we observed in the case of hatching in darkness (control group C), when the hatching time was 510.41 +/- 2.82 h, hatchability 90.42 +/- 3.35% and average weight of incubated chickens 41.98 +/- 3.05 g.

  17. Filling material for a buried cavity in a collapse area using light-weighted foam and active feldspar

    NASA Astrophysics Data System (ADS)

    Cho, Jin Woo; Lee, Ju-hyoung; Kim, Sung-Wook; Choi, Eun-Kyeong

    2017-04-01

    Concrete which is generally used as filling material for a buried cavity has very high strength but significantly high self-load is considered its disadvantage. If it is used as filling material, the second collapse due to additional load, causing irreversible damage. If light-weighted foam and active feldspar are used to solve this problem, the second collapse can be prevented by reducing of self-load of filling material. In this study, the specimen was produced by mixing light-weighted foam, active feldspar and cement, and changes in the density, unconfined compressive strength and hydraulic conductivity were analyzed. Using the light-weighted foam could enable the adjustment of density of specimen between 0.5 g/cm3 and 1.7 g/cm3, and if the mixing ratio of the light-weighted foam increases, the specimen has more pores and smaller range of cross-sectional area. It is confirmed that it has direct correlation with the density, and if the specimen has more pores, the density of the specimen is lowered. The density of the specimen influences the unconfined compressive strength and the hydraulic conductivity, and it was also confirmed that the unconfined compressive strength could be adjusted between 0.6 MPa and 8 MPa and the hydraulic conductivity could be adjusted between 10-9cm/sec and 10-3cm/sec. These results indicated that we can adjust unconfined compressive strength and hydraulic conductivity of filling materials by changing the mixing amount of lightweight-weighted foam according to the requirements of the field condition. Keywords: filling material, buried cavity, light-weighted foam, feldspar Acknowledgement This research was supported by a Grant from a Strategic Research Project (Horizontal Drilling and Stabilization Technologies for Urban Search and Rescue (US&R) Operation) funded by the Korea Institute of Civil Engineering and Building Technology.

  18. Stellar Populations of over 1000 z ∼ 0.8 Galaxies from LEGA-C: Ages and Star Formation Histories from D n 4000 and Hδ

    NASA Astrophysics Data System (ADS)

    Wu, Po-Feng; van der Wel, Arjen; Gallazzi, Anna; Bezanson, Rachel; Pacifici, Camilla; Straatman, Caroline; Franx, Marijn; Barišić, Ivana; Bell, Eric F.; Brammer, Gabriel B.; Calhau, Joao; Chauke, Priscilla; van Houdt, Josha; Maseda, Michael V.; Muzzin, Adam; Rix, Hans-Walter; Sobral, David; Spilker, Justin; van de Sande, Jesse; van Dokkum, Pieter; Wild, Vivienne

    2018-03-01

    Drawing from the LEGA-C data set, we present the spectroscopic view of the stellar population across a large volume- and mass-selected sample of galaxies at large look-back time. We measure the 4000 Å break (D n 4000) and Balmer absorption line strengths (probed by Hδ) from 1019 high-quality spectra of z = 0.6–1.0 galaxies with M * = 2 × 1010 M ⊙ to 3 × 1011 M ⊙. Our analysis serves as a first illustration of the power of high-resolution, high signal-to-noise ratio continuum spectroscopy at intermediate redshifts as a qualitatively new tool to constrain galaxy formation models. The observed D n 4000–EW(Hδ) distribution of our sample overlaps with the distribution traced by present-day galaxies, but z ∼ 0.8 galaxies populate that locus in a fundamentally different manner. While old galaxies dominate the present-day population at all stellar masses >2 × 1010 M ⊙, we see a bimodal D n 4000–EW(Hδ) distribution at z ∼ 0.8, implying a bimodal light-weighted age distribution. The light-weighted age depends strongly on stellar mass, with the most massive galaxies >1 × 1011 M ⊙ being almost all older than 2 Gyr. At the same time, we estimate that galaxies in this high-mass range are only ∼3 Gyr younger than their z ∼ 0.1 counterparts, at odds with purely passive evolution given a difference in look-back time of >5 Gyr; younger galaxies must grow to >1011 M ⊙ in the meantime, or small amounts of young stars must keep the light-weighted ages young. Star-forming galaxies at z ∼ 0.8 have stronger Hδ absorption than present-day galaxies with the same D n 4000, implying larger short-term variations in star formation activity.

  19. Portable, Fiber-Based, Diffuse Reflection Spectroscopy (DRS) Systems for Estimating Tissue Optical Properties.

    PubMed

    Vishwanath, Karthik; Chang, Kevin; Klein, Daniel; Deng, Yu Feng; Chang, Vivide; Phelps, Janelle E; Ramanujam, Nimmi

    2011-02-01

    Steady-state diffuse reflection spectroscopy is a well-studied optical technique that can provide a noninvasive and quantitative method for characterizing the absorption and scattering properties of biological tissues. Here, we compare three fiber-based diffuse reflection spectroscopy systems that were assembled to create a light-weight, portable, and robust optical spectrometer that could be easily translated for repeated and reliable use in mobile settings. The three systems were built using a broadband light source and a compact, commercially available spectrograph. We tested two different light sources and two spectrographs (manufactured by two different vendors). The assembled systems were characterized by their signal-to-noise ratios, the source-intensity drifts, and detector linearity. We quantified the performance of these instruments in extracting optical properties from diffuse reflectance spectra in tissue-mimicking liquid phantoms with well-controlled optical absorption and scattering coefficients. We show that all assembled systems were able to extract the optical absorption and scattering properties with errors less than 10%, while providing greater than ten-fold decrease in footprint and cost (relative to a previously well-characterized and widely used commercial system). Finally, we demonstrate the use of these small systems to measure optical biomarkers in vivo in a small-animal model cancer therapy study. We show that optical measurements from the simple portable system provide estimates of tumor oxygen saturation similar to those detected using the commercial system in murine tumor models of head and neck cancer.

  20. Fast, Large-Area, Wide-Bandgap UV Photodetector for Cherenkov Light Detection

    NASA Technical Reports Server (NTRS)

    Wrbanek, John D.; Wrbanek, Susan Y.

    2013-01-01

    Due to limited resources available for power and space for payloads, miniaturizing and integrating instrumentation is a high priority for addressing the challenges of manned and unmanned deep space missions to high Earth orbit (HEO), near Earth objects (NEOs), Lunar and Martian orbits and surfaces, and outer planetary systems, as well as improvements to high-altitude aircraft safety. New, robust, and compact detectors allow future instrumentation packages more options in satisfying specific mission goals. A solid-state ultraviolet (UV) detector was developed with a theoretical fast response time and large detection area intended for application to Cherenkov detectors. The detector is based on the wide-bandgap semiconductor zinc oxide (ZnO), which in a bridge circuit can detect small, fast pulses of UV light like those required for Cherenkov detectors. The goal is to replace the role of photomultiplier tubes in Cherenkov detectors with these solid-state devices, saving on size, weight, and required power. For improving detection geometry, a spherical detector to measure high atomic number and energy (HZE) ions from any direction has been patented as part of a larger space radiation detector system. The detector will require the development of solid-state UV photodetectors fast enough (2 ns response time or better) to detect the shockwave of Cherenkov light emitted as the ions pass through a quartz, sapphire, or acrylic ball. The detector must be small enough to fit in the detector system structure, but have an active area large enough to capture enough Cherenkov light from the sphere. The detector is fabricated on bulk single-crystal undoped ZnO. Inter - digitated finger electrodes and contact pads are patterned via photolithography, and formed by sputtered metal of silver, platinum, or other high-conductivity metal.

  1. Passive Wireless SAW Sensors for IVHM

    NASA Technical Reports Server (NTRS)

    Wilson, William C.; Perey, Daniel F.; Atkinson, Gary M.; Barclay, Rebecca O.

    2008-01-01

    NASA aeronautical programs require integrated vehicle health monitoring (IVHM) to ensure the safety of the crew and the vehicles. Future IVHM sensors need to be small, light weight, inexpensive, and wireless. Surface acoustic wave (SAW) technology meets all of these constraints. In addition it operates in harsh environments and over wide temperature ranges, and it is inherently radiation hardened. This paper presents a survey of research opportunities for universities and industry to develop new sensors that address anticipated IVHM needs for aerospace vehicles. Potential applications of passive wireless SAW sensors from ground testing to high altitude aircraft operations are presented, along with some of the challenges and issues of the technology.

  2. Czechoslovak Replica X-Ray Mirrors for Astronomical Applications

    NASA Astrophysics Data System (ADS)

    Hudec, R.; Valnicek, B.

    Imaging X-ray mirrors has been developed in Czechoslovakia since 1970 by a way of two different replica technologies based on galvanoplastics and reactoplastics as a natural part of Czechoslovak X-ray astronomy program. Until now about 30 mirros with diameters between 1.7 and 24 cm were manufactured. Seven mirrors were flown in space experiments. The new technology used since 1981 allows to produce light-weight X-ray mirrors at relatively very low cost. The technology offers interesting possibilities in construction of (1) large arrays of identical optical systems, (2) very small (microscopic) mirros and (3) lobster-eye type optics. Advantages and drawbacks of replica techology are discussed.

  3. A microspectrometer based on subwavelength metal nanohole array

    NASA Astrophysics Data System (ADS)

    Cui, Jun; Xia, Liangping; Yang, Zheng; Yin, Lu; Zheng, Guoxing; Yin, Shaoyun; Du, Chunlei

    2014-11-01

    Catering to the active demand of the miniaturization of spectrometers, a simple microspectrometer with small size and light weight is presented in this paper. The presented microspectrometer is a typical filter-based spectrometer using the extraordinary optical transmission property of subwavelength metal hole array structure. Different subwavelength metal nanohole arrays are designed to work as different filter units obtained by changing the lattice parameters. By processing the filter spectra with a unique algorithm based on sparse representation, the proposed spectrometer is demonstrated to have the capability of high spectral resolution and accuracy. Benefit for the thin filmed feature, the microspectrometer is expected to find its application in integrated optical systems.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Gregory L.; Arnold, Dorian; LeGendre, Matthew

    STAT is a light weight debugging tool that gathers and merges stack traces from all of the processes in a parallel application. STAT uses the MRNet tree based overlay network to broadcast commands from the tool front-end to the STAT daemons and for the front-end to gather the traces from the STAT daemons. As the traces propagate through the MRNet network tree, they are merged across all tasks to form a similar function call patterns and to delineate a small set of equivalence classes. A representative task from each of these classes can then be fed into a full featuremore » debugger like TolalView for root cause analysis.« less

  5. Chain-Growth Methods for the Synthesis of High Molecular Weight Conducting and Semiconducting Polymers

    DTIC Science & Technology

    2013-08-25

    to produce the desired polymerization in analogy to the well-known “super glue ” anionic polymerization. Although there are abundant examples of...light (a) and UV light (b). 5 are further functionalized and block polymers formed with polynorborene have elastomeric properties. The...top) and UV (bottom) light show the evolution of the band gap of the polymer with increasing molecular weight. The plot on the right shows the

  6. Mapping algorithm for freeform construction using non-ideal light sources

    NASA Astrophysics Data System (ADS)

    Li, Chen; Michaelis, D.; Schreiber, P.; Dick, L.; Bräuer, A.

    2015-09-01

    Using conventional mapping algorithms for the construction of illumination freeform optics' arbitrary target pattern can be obtained for idealized sources, e.g. collimated light or point sources. Each freeform surface element generates an image point at the target and the light intensity of an image point is corresponding to the area of the freeform surface element who generates the image point. For sources with a pronounced extension and ray divergence, e.g. an LED with a small source-freeform-distance, the image points are blurred and the blurred patterns might be different between different points. Besides, due to Fresnel losses and vignetting, the relationship between light intensity of image points and area of freeform surface elements becomes complicated. These individual light distributions of each freeform element are taken into account in a mapping algorithm. To this end the method of steepest decent procedures are used to adapt the mapping goal. A structured target pattern for a optics system with an ideal source is computed applying corresponding linear optimization matrices. Special weighting factor and smoothing factor are included in the procedures to achieve certain edge conditions and to ensure the manufacturability of the freefrom surface. The corresponding linear optimization matrices, which are the lighting distribution patterns of each of the freeform surface elements, are gained by conventional raytracing with a realistic source. Nontrivial source geometries, like LED-irregularities due to bonding or source fine structures, and a complex ray divergence behavior can be easily considered. Additionally, Fresnel losses, vignetting and even stray light are taken into account. After optimization iterations, with a realistic source, the initial mapping goal can be achieved by the optics system providing a structured target pattern with an ideal source. The algorithm is applied to several design examples. A few simple tasks are presented to discussed the ability and limitation of the this mothed. It is also presented that a homogeneous LED-illumination system design, in where, with a strongly tilted incident direction, a homogeneous distribution is achieved with a rather compact optics system and short working distance applying a relatively large LED source. It is shown that the lighting distribution patterns from the freeform surface elements can be significantly different from the others. The generation of a structured target pattern, applying weighting factor and smoothing factor, are discussed. Finally, freeform designs for much more complex sources like clusters of LED-sources are presented.

  7. The effect of simulating weight gain on the energy cost of walking in unimpaired children and children with cerebral palsy.

    PubMed

    Plasschaert, Frank; Jones, Kim; Forward, Malcolm

    2008-12-01

    To examine the effect of simulating weight gain on the energy cost of walking in children with cerebral palsy (CP) compared with unimpaired children. Repeated measures, matched subjects, controlled. University hospital clinical gait and movement analysis laboratory. Children (n=42) with CP and unimpaired children (n=42). Addition of 10% of body mass in weight belt. Energy cost of walking parameters consisting of walking speed, Physiological Cost Index, Total Heart Beat Index, oxygen uptake (VO2), gross oxygen cost, nondimensional net oxygen cost, and net oxygen cost with speed normalized to height were measured by using a breath-by-breath gas analysis system (K4b2) and a light beam timing gate system arranged around a figure 8 track. Two walking trials were performed in random order, with and the other without wearing a weighted belt. Children with CP and their unimpaired counterparts responded in fundamentally different ways to weight gain. The unimpaired population maintained speed and VO2 but the children with CP trended toward a drop in their speed and an increase in their VO2. The oxygen consumption of children with CP showed a greater dependence on mass than the unimpaired group (P=.043). An increase of a relatively small percentage in body mass began to significantly impact the energy cost of walking in children with CP. This result highlights the need for weight control to sustain the level of functional walking in these children.

  8. High strength, light weight Ti-Y composites and method of making same

    DOEpatents

    Verhoeven, John D.; Ellis, Timothy W.; Russell, Alan M.; Jones, Lawrence L.

    1993-04-06

    A high strength, light weight "in-situ" Ti-Y composite is produced by deformation processing a cast body having Ti and Y phase components distributed therein. The composite comprises elongated, ribbon-shaped Ti and Y phase components aligned along an axis of the deformed body.

  9. 40 CFR 52.1670 - Identification of plans.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... percent, by weight, for the Long Island Lighting Co.'s Northport Generating Facility (Units 1, 2, and 3... oil limitation to 1.0 percent, by weight, for the Long Island Lighting Company's Glenwood Generating... of New York, Inc. Arthur Kill generating facility, units 2 and 3, Staten Island, New York and...

  10. Weight Reduction Potential of Automobiles and Light Trucks, 1979 Summary Source Document

    DOT National Transportation Integrated Search

    1980-03-01

    The purpose of this report is to provide an assessment of the potential for weight reduction for passenger cars and light trucks (including pickup trucks, vans, and utility vehicles of GVWR up to 8500 pounds) in the 1980 to 2000 model year period. Va...

  11. High strength, light weight Ti-Y composites and method of making same

    DOEpatents

    Verhoeven, J.D.; Ellis, T.W.; Russell, A.M.; Jones, L.L.

    1993-04-06

    A high strength, light weight in-situ'' Ti-Y composite is produced by deformation processing a cast body having Ti and Y phase components distributed therein. The composite comprises elongated, ribbon-shaped Ti and Y phase components aligned along an axis of the deformed body.

  12. Control torque generation of a CMG-based small satellite with MTGAC system: a trade-off study

    NASA Astrophysics Data System (ADS)

    Salleh, M. B.; Suhadis, N. M.; Rajendran, P.; Mazlan, N. M.

    2018-05-01

    In this paper, the gimbal angle compensation method using magnetic control law has been adopted for a small satellite operating in low earth orbit under disturbance toques influence. Three light weight magnetic torquers have been used to generate the magnetic compensation torque to bring diverge gimbals at preferable angle. The magnetic control torque required to compensate the gimbal angle is based on the gimbal error rate which depends on the gimbal angle converging time. A simulation study has been performed without and with the MTGAC system to investigate the amount of generated control torque as a trade-off between the power consumption, attitude control performance and CMG dynamic performance. Numerical simulations show that the satellite with the MTGAC system generates more control torques which leads to the additional power requirement but in return results in a favorable attitude control performance and gimbal angle management.

  13. Towards the miniaturization of monolithic folded pendulums: a new approach to the implementation of small and light sensors for ground, space, and marine applications

    NASA Astrophysics Data System (ADS)

    Barone, F.; Giordano, G.

    2018-03-01

    The UNISA Folded Pendulum technological platform is very promising for the implementation of high sensitive, large band miniaturized mechanical seismometers and accelerometers in different materials. In fact, the symmetry of its mechanical architecture allows to take full advantage of one of the most relevant properties of the folded pendulum, that is the scalability. This property is very useful for the design of folded pendulums of small size and weight, provided with a suitable combination of physical and geometrical parameters. Using a lagrangian simplified model of folded pendulum, we present and discuss this idea, showing different possible approaches that may lead to the miniaturization of a folded pendulum. Finally we present a first prototype of miniaturized folded pendulum, discussing its characteristics and limitations, in connection with scientific ground, marine and space applications.

  14. Discussion on back-to-back two-stage centrifugal compressor compact design techniques

    NASA Astrophysics Data System (ADS)

    Huo, Lei; Liu, Huoxing

    2013-12-01

    Design a small flow back-to-back two-stage centrifugal compressor in the aviation turbocharger, the compressor is compact structure, small axial length, light weighted. Stationary parts have a great influence on their overall performance decline. Therefore, the stationary part of the back-to-back two-stage centrifugal compressor should pay full attention to the diffuser, bend, return vane and volute design. Volute also impact downstream return vane, making the flow in circumferential direction is not uniformed, and several blade angle of attack is drastically changed in downstream of the volute with the airflow can not be rotated to required angle. Loading of high-pressure rotor blades change due to non-uniformed of flow in circumferential direction, which makes individual blade load distribution changed, and affected blade passage load decreased to reduce the capability of work, the tip low speed range increases.

  15. The influence of the recipient's body weight on the probability to obtain a heart transplant-POLKARD HF registry.

    PubMed

    Zieliński, T; Sobieszczańska-Małek, M; Browarek, A; Piotrowska, M; Zakliczyński, M; Przybyłowski, P; Roguski, K; Sadowski, J; Zembala, M; Korewicki, J

    2009-10-01

    The aim of the study was to analyze the influence of body weight of the adult heart recipient on the chance to obtain a transplant. We analyzed the data from all 658 patients listed for heart transplantation. During the follow-up period, 325 (49%) of listed patients underwent transplantation with 102 (15%) succumbing before heart transplantation. The mean weight of transplanted patients was 73.7 +/- 13.7 kg and 81.2 +/- 15.4 kg for those not transplanted (P < .00001). Patients were divided according to body weight in two groups: light = below 80 kg (n = 360) or heavy > or = 80 kg or above (n = 297). On the transplant list, 111 heavy patients (37%) versus 213 light patients (59%) underwent the procedure, a significant difference. The waiting time among light patients was 255 versus heavy patients of 395 days (P < .005). There was a similar number of deaths before transplantation among the light (n = 56 360 patients; 15.5%) versus the heavy group (49/297; 16%). Upon multivariate Cox mode analysis independent factors related to not receiving a heart transplant were greater weight, systolic blood pressure, pulmonary vascular resistance, Heart Failure Survival Score (HFSS) score and lower N-terminal pro-brain natriuretic peptide (NTproBNP) levels. Among adult heart transplant candidates, the chance to receive a heart transplant significantly decreased when the recipient's weight exceeded 80 kg. Patients with a body weight more than 110 kg had a poor chance to receive a heart transplantation.

  16. Comparison of Blue and White Lamp Light with Sunlight for Daylight-Mediated, 5-ALA Photodynamic Therapy, in vivo.

    PubMed

    Marra, Kayla; LaRochelle, Ethan P; Chapman, M Shane; Hoopes, P Jack; Lukovits, Karina; Maytin, Edward V; Hasan, Tayyaba; Pogue, Brian W

    2018-04-16

    Daylight-mediated photodynamic therapy (d-PDT) as a treatment for actinic keratosis (AK) is an increasingly common technique due to a significant reduction in pain, leading to better patient tolerability. While past studies have looked at different light sources and delivery methods, this study strives to provide equivalent PpIX-weighted light doses with the hypothesis that artificial light sources could be equally as effective as natural sunlight if their PpIX-weighted fluences were equalized. Normal mouse skin was used as the model to compare blue LED light, metal halide white light and natural sunlight, with minimal incubation time between topical ALA application and the onset of light delivery. A total PpIX-weighted fluence of 20 J eff cm -2 was delivered over 2 h, and the efficacy of response was quantified using three acute bioassays for PDT damage: PpIX photobleaching, Stat3 crosslinking and quantitative histopathology. These bioassays indicated blue light was slightly inferior to both sunlight and white light, but that the latter two were not significantly different. The results suggest that metal halide white light could be a reasonable alternative to daylight PDT, which should allow a more controlled treatment that is independent of weather and yet should have similar response rates with limited pain during treatment. © 2018 The American Society of Photobiology.

  17. Method for controlling boiling point distribution of coal liquefaction oil product

    DOEpatents

    Anderson, R.P.; Schmalzer, D.K.; Wright, C.H.

    1982-12-21

    The relative ratio of heavy distillate to light distillate produced in a coal liquefaction process is continuously controlled by automatically and continuously controlling the ratio of heavy distillate to light distillate in a liquid solvent used to form the feed slurry to the coal liquefaction zone, and varying the weight ratio of heavy distillate to light distillate in the liquid solvent inversely with respect to the desired weight ratio of heavy distillate to light distillate in the distillate fuel oil product. The concentration of light distillate and heavy distillate in the liquid solvent is controlled by recycling predetermined amounts of light distillate and heavy distillate for admixture with feed coal to the process in accordance with the foregoing relationships. 3 figs.

  18. Method for controlling boiling point distribution of coal liquefaction oil product

    DOEpatents

    Anderson, Raymond P.; Schmalzer, David K.; Wright, Charles H.

    1982-12-21

    The relative ratio of heavy distillate to light distillate produced in a coal liquefaction process is continuously controlled by automatically and continuously controlling the ratio of heavy distillate to light distillate in a liquid solvent used to form the feed slurry to the coal liquefaction zone, and varying the weight ratio of heavy distillate to light distillate in the liquid solvent inversely with respect to the desired weight ratio of heavy distillate to light distillate in the distillate fuel oil product. The concentration of light distillate and heavy distillate in the liquid solvent is controlled by recycling predetermined amounts of light distillate and heavy distillate for admixture with feed coal to the process in accordance with the foregoing relationships.

  19. A method to estimate weight and dimensions of small aircraft propulsion gas turbine engines: User's guide

    NASA Technical Reports Server (NTRS)

    Hale, P. L.

    1982-01-01

    The weight and major envelope dimensions of small aircraft propulsion gas turbine engines are estimated. The computerized method, called WATE-S (Weight Analysis of Turbine Engines-Small) is a derivative of the WATE-2 computer code. WATE-S determines the weight of each major component in the engine including compressors, burners, turbines, heat exchangers, nozzles, propellers, and accessories. A preliminary design approach is used where the stress levels, maximum pressures and temperatures, material properties, geometry, stage loading, hub/tip radius ratio, and mechanical overspeed are used to determine the component weights and dimensions. The accuracy of the method is generally better than + or - 10 percent as verified by analysis of four small aircraft propulsion gas turbine engines.

  20. Design of an ultra-thin near-eye display with geometrical waveguide and freeform optics.

    PubMed

    Cheng, Dewen; Wang, Yongtian; Xu, Chen; Song, Weitao; Jin, Guofan

    2014-08-25

    Small thickness and light weight are two important requirements for a see-through near-eye display which are achieved in this paper by using two advanced technologies: geometrical waveguide and freeform optics. A major problem associated with the geometrical waveguide is the stray light which can severely degrade the display quality. The causes and solutions to this problem are thoroughly studied. A mathematical model of the waveguide is established and a non-sequential ray tracing algorithm is developed, which enable us to carefully examine the stray light of the planar waveguide and explore a global searching method to find an optimum design with the least amount of stray light. A projection optics using freeform surfaces on a wedge shaped prism is also designed. The near-eye display integrating the projection optics and the waveguide has a field of view of 28°, an exit pupil diameter of 9.6mm and an exit pupil distance of 20mm. In our final design, the proportion of the stray light energy over the image output energy of the waveguide is reduced to 2%, the modulation transfer function values across the entire field of the eyepiece are above 0.5 at 30 line pairs/mm (lps/mm). A proof-of-concept prototype of the proposed geometrical waveguide near-eye display is developed and demonstrated.

  1. Optical gyroscope

    NASA Astrophysics Data System (ADS)

    Seifollahi, Alireza

    It is said that future of the world is based on space exploration which leads us to think more about low cost and light weight instruments. Cheap and sensitive instruments should be de-signed and replace the expensive ones. One of the required instruments in space ships is gyroscope controls the direction of space ship. In this article I am going to give an idea to use optical properties in a new gyroscope which will be cheaper as well as more sensitive in com-pare with most of the being used normal gyroscope nowadays. This instrument uses an optical system to measure the angular changes in the direction of a space craft movements in any of the three axels. Any movement, even very small one, will move a crystal bulb which is lashed by some narrow elastic bands in a fixed box surrounded by three optical sources and light meters. Light meters measure the attitude and the angel of changes in the light beams going through the bulb which is related to the amount of changes in the space craft directions. The system will be very sensitive even against movement around its access. As an electro digital device in connection to a Main Process Unit (MPU) it can be used in Stability Augmentation System (SAS) in a space ship. The sensitivity rate of the instrument will be based on the quality and sensitivity of the light meters.

  2. Paraprotein-Related Kidney Disease: Evaluation and Treatment of Myeloma Cast Nephropathy.

    PubMed

    Finkel, Kevin W; Cohen, Eric P; Shirali, Anushree; Abudayyeh, Ala

    2016-12-07

    Nearly 50% of patients with multiple myeloma develop renal disease, most commonly from AKI caused by cast nephropathy. Development of AKI is associated with poor 1-year survival and reduces the therapeutic options available to patients. There is a great need for more effective therapies. Cast nephropathy is caused by the interaction and aggregation of filtered free light chains and Tamm-Horsfall protein causing intratubular obstruction and damage. The key to treating cast nephropathy is rapid lowering of free light chains, because this correlates with renal recovery. Newer chemotherapy agents rapidly lower free light chains and have been referred to as renoprotective. There is additional great interest in using extracorporeal therapies to remove serum free light chains. Small trials initially showed benefit of therapeutic plasma exchange to improve renal outcomes in cast nephropathy, but a large randomized trial of therapeutic plasma exchange failed to show benefit. A newer technique is extended high-cutoff hemodialysis. This modality uses a high molecular weight cutoff filter to remove free light chains. To date, trials of high-cutoff hemodialysis use in patients with cast nephropathy have been encouraging. However, there are no randomized trials showing the benefit of high-cutoff hemodialysis when used in addition to newer chemotherapeutic regimens. Until these studies are available, high-cutoff hemodialysis cannot be recommended as standard of care. Copyright © 2016 by the American Society of Nephrology.

  3. Influence of three artificial light sources on oviposition and half-life of the Black Soldier Fly, Hermetia illucens (Diptera: Stratiomyidae): Improving small-scale indoor rearing.

    PubMed

    Heussler, Carina D; Walter, Andreas; Oberkofler, Hannes; Insam, Heribert; Arthofer, Wolfgang; Schlick-Steiner, Birgit C; Steiner, Florian M

    2018-01-01

    Hermetia illucens (L.), the Black Soldier Fly, has received increased scientific attention for its potential in circular waste management where larvae can serve as feedstuff for livestock and for biodiesel production. The flies occur naturally in (sub)-tropical and warm-temperate climates, and their mating depends on space and sunlight. Small-scale indoor rearing of Black Soldier Flies has been challenging because they react sensitive to artificial light sources and cage sizes, but recent studies have shown that small-scale rearing under artificial light is feasible. Here, we test the influence of three artificial light sources (light-emitting diodes, fluorescent lamps, and halogen lamps) on small-scale indoor rearing. Three experiments were conducted to compare oviposition traits (pre-oviposition period, total oviposition-period, and egg mass per female) and half-life among the three light sources. Oviposition did not differ among the three light sources, but male and female half-life did. Based on the performance of the light-emitting diodes and their outstanding energy efficiency, we recommend this light source for small-scale indoor rearing of Black Soldier Flies.

  4. Solar light irradiation significantly reduced cytotoxicity and disinfection byproducts in chlorinated reclaimed water.

    PubMed

    Lv, Xiao-Tong; Zhang, Xue; Du, Ye; Wu, Qian-Yuan; Lu, Yun; Hu, Hong-Ying

    2017-11-15

    Chlorinated reclaimed water is widely used for landscaping and recreational purposes, resulting in human exposure to toxic disinfection byproducts. Although the quality of chlorinated reclaimed water might be affected by sunlight during storage, the effects of solar light irradiation on the toxicity remain unknown. This study investigated the changes in cytotoxicity and total organic halogen (TOX) of chlorinated reclaimed water exposed to solar light. Irradiation with solar light for 12 h was found to significantly reduce the cytotoxicity of chlorinated reclaimed water by about 75%, with ultraviolet light being responsible for the majority of this reduction. Chlorine residual in reclaimed water tended to increase the cytotoxicity, and the synergy between solar light and free chlorine could not enhance the reduction of cytotoxicity. Adding hydroxyl radical scavengers revealed that the contribution of hydroxyl radical to cytotoxicity reduction was limited. Solar light irradiation concurrently reduced TOX. The low molecular weight (<1 kDa) fraction was the major contributor of cytotoxicity and TOX in chlorinated reclaimed water. Detoxification of the low molecular weight fraction by light irradiation was mainly a result of TOX dehalogenation, while detoxification of the high molecular weight (>1 kDa) fraction was probably caused by photoconversion from high toxic TOX to low toxic TOX. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Disrupting Illicit Small Arms Trafficking in the Middle East

    DTIC Science & Technology

    2008-12-01

    personal use and light weapons as weapons designed for use by a crew. Small arms include revolvers, self-loading pistols, rifles, sub- machine guns...assault rifles, and light machine guns. Light weapons include machine -guns, mortars, hand grenades, grenade launchers, portable anti-aircraft guns...71 David Atwood , Anne-Katherin Glatz, and Robert Muggah, Demanding Attention: Addressing the Dynamics of Small Arms Demand (Geneva: Small Arms

  6. White organic light-emitting diodes with ultra-thin mixed emitting layer

    NASA Astrophysics Data System (ADS)

    Jeon, T.; Forget, S.; Chenais, S.; Geffroy, B.; Tondelier, D.; Bonnassieux, Y.; Ishow, E.

    2012-02-01

    White light can be obtained from Organic Light Emitting Diodes by mixing three primary colors, (i.e. red, green and blue) or two complementary colors in the emissive layer. In order to improve the efficiency and stability of the devices, a host-guest system is generally used as an emitting layer. However, the color balance to obtain white light is difficult to control and optimize because the spectrum is very sensitive to doping concentration (especially when a small amount of material is used). We use here an ultra-thin mixed emitting layer (UML) deposited by thermal evaporation to fabricate white organic light emitting diodes (WOLEDs) without co-evaporation. The UML was inserted in the hole-transporting layer consisting of 4, 4'-bis[N-(1-naphtyl)-N-phenylamino]biphenyl (α-NPB) instead of using a conventional doping process. The UML was formed from a single evaporation boat containing a mixture of two dipolar starbust triarylamine molecules (fvin and fcho) presenting very similar structures and thermal properties and emitting in complementary spectral regions (orange and blue respectively) and mixed according to their weight ratio. The composition of the UML specifically allows for fine tuning of the emission color despite its very thin thickness down to 1 nm. Competitive energy transfer processes from fcho and the host interface toward fvin are key parameters to control the relative intensity between red and blue emission. White light with very good CIE 1931 color coordinate (0.34, 0.34) was obtained by simply adjusting the UML film composition.

  7. ‘Small Changes’ to Diet and Physical Activity Behaviors for Weight Management

    PubMed Central

    Hills, Andrew P.; Byrne, Nuala M.; Lindstrom, Rachel; Hill, James O.

    2013-01-01

    Obesity is associated with numerous short- and long-term health consequences. Low levels of physical activity and poor dietary habits are consistent with an increased risk of obesity in an obesogenic environment. Relatively little research has investigated associations between eating and activity behaviors by using a systems biology approach and by considering the dynamics of the energy balance concept. A significant body of research indicates that a small positive energy balance over time is sufficient to cause weight gain in many individuals. In contrast, small changes in nutrition and physical activity behaviors can prevent weight gain. In the context of weight management, it may be more feasible for most people to make small compared to large short-term changes in diet and activity. This paper presents a case for the use of small and incremental changes in diet and physical activity for improved weight management in the context of a toxic obesogenic environment. PMID:23711772

  8. Design and Calibration of a Novel Bio-Inspired Pixelated Polarized Light Compass.

    PubMed

    Han, Guoliang; Hu, Xiaoping; Lian, Junxiang; He, Xiaofeng; Zhang, Lilian; Wang, Yujie; Dong, Fengliang

    2017-11-14

    Animals, such as Savannah sparrows and North American monarch butterflies, are able to obtain compass information from skylight polarization patterns to help them navigate effectively and robustly. Inspired by excellent navigation ability of animals, this paper proposes a novel image-based polarized light compass, which has the advantages of having a small size and being light weight. Firstly, the polarized light compass, which is composed of a Charge Coupled Device (CCD) camera, a pixelated polarizer array and a wide-angle lens, is introduced. Secondly, the measurement method of a skylight polarization pattern and the orientation method based on a single scattering Rayleigh model are presented. Thirdly, the error model of the sensor, mainly including the response error of CCD pixels and the installation error of the pixelated polarizer, is established. A calibration method based on iterative least squares estimation is proposed. In the outdoor environment, the skylight polarization pattern can be measured in real time by our sensor. The orientation accuracy of the sensor increases with the decrease of the solar elevation angle, and the standard deviation of orientation error is 0 . 15 ∘ at sunset. Results of outdoor experiments show that the proposed polarization navigation sensor can be used for outdoor autonomous navigation.

  9. Design and Calibration of a Novel Bio-Inspired Pixelated Polarized Light Compass

    PubMed Central

    Hu, Xiaoping; Lian, Junxiang; He, Xiaofeng; Zhang, Lilian; Wang, Yujie; Dong, Fengliang

    2017-01-01

    Animals, such as Savannah sparrows and North American monarch butterflies, are able to obtain compass information from skylight polarization patterns to help them navigate effectively and robustly. Inspired by excellent navigation ability of animals, this paper proposes a novel image-based polarized light compass, which has the advantages of having a small size and being light weight. Firstly, the polarized light compass, which is composed of a Charge Coupled Device (CCD) camera, a pixelated polarizer array and a wide-angle lens, is introduced. Secondly, the measurement method of a skylight polarization pattern and the orientation method based on a single scattering Rayleigh model are presented. Thirdly, the error model of the sensor, mainly including the response error of CCD pixels and the installation error of the pixelated polarizer, is established. A calibration method based on iterative least squares estimation is proposed. In the outdoor environment, the skylight polarization pattern can be measured in real time by our sensor. The orientation accuracy of the sensor increases with the decrease of the solar elevation angle, and the standard deviation of orientation error is 0.15∘ at sunset. Results of outdoor experiments show that the proposed polarization navigation sensor can be used for outdoor autonomous navigation. PMID:29135927

  10. Effect of varying light intensity on welfare indices of broiler chickens grown to heavy weights

    USDA-ARS?s Scientific Manuscript database

    The effects of varying light-intensity on ocular, immue, fear, and leg health of broiler chickens grown to heavy weights under environmentally controlled conditions were evaluated. Four identical trials were conducted with two replications per trial. In each trial, 600 Ross 308 chicks were randomly ...

  11. Effects of color temperatures (kelvin) of led bulbs on blood physiological variables of broilers grown to heavy weights

    USDA-ARS?s Scientific Manuscript database

    Light-emitting diode (LED) lighting is being used in the poultry industry to reduce energy usage in broiler production facilities. However, limited data are available comparing efficacy of different spectral distribution of LED bulbs on blood physiological variables of broilers grown to heavy weight...

  12. 40 CFR 52.1689 - Original Identification of plan section.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... percent, by weight, for the Long Island Lighting Co.'s Northport Generating Facility (Units 1, 2, and 3... oil limitation to 1.0 percent, by weight, for the Long Island Lighting Company's Glenwood Generating... of New York, Inc. Arthur Kill generating facility, units 2 and 3, Staten Island, New York and...

  13. 40 CFR 52.1689 - Original Identification of plan section.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... percent, by weight, for the Long Island Lighting Co.'s Northport Generating Facility (Units 1, 2, and 3... oil limitation to 1.0 percent, by weight, for the Long Island Lighting Company's Glenwood Generating... of New York, Inc. Arthur Kill generating facility, units 2 and 3, Staten Island, New York and...

  14. 40 CFR 52.1689 - Original identification of plan section.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... percent, by weight, for the Long Island Lighting Co.'s Northport Generating Facility (Units 1, 2, and 3... oil limitation to 1.0 percent, by weight, for the Long Island Lighting Company's Glenwood Generating... of New York, Inc. Arthur Kill generating facility, units 2 and 3, Staten Island, New York and...

  15. A small graphene oxide sheet/polyvinylidene fluoride bilayer actuator with large and rapid responses to multiple stimuli.

    PubMed

    Xu, Guochuang; Zhang, Miao; Zhou, Qinqin; Chen, Hongwu; Gao, Tiantian; Li, Chun; Shi, Gaoquan

    2017-11-16

    A high-performance actuator should be able to deliver large-shape deformations, fast actuations and sensitive responses to multiple stimuli. Here, we report such an actuator constructed from one layer of polyvinylidene fluoride (PVDF) with a high coefficient of thermal expansion (CTE), and another layer of small sheets of graphene oxide (SGO) with a negative CTE. The opposite deformations of both actuation layers make the SGO/PVDF bilayer actuator highly sensitive to the temperature stimulus with a large bending sensitivity of 1.5 cm -1 °C -1 . Upon irradiation with 60 mW cm -2 infrared light, this SGO/PVDF bilayer actuator displayed an extremely rapid tip displacement rate of 140 mm s -1 . Furthermore, this actuator can also sensitively respond to moisture because of its SGO layer, showing a curvature change from -22 to 13 cm -1 upon changing the relative humidity (RH) from 11% to 86%. This actuator can generate a contractile or relaxed stress 18 times that of mammalian skeletal muscle, under light irradiation or moisture with a response time as short as 1 s, being capable of lifting an object with a weight 80 times that of itself. Furthermore, it also showed excellent stability and repeatability.

  16. Hand-Held Photometer for Instant On-Spot Quantification of Nucleic Acids, Proteins, and Cells.

    PubMed

    Li, Shi-Hao; Jain, Abhinav; Tscharntke, Timo; Arnold, Tobias; Trau, Dieter W

    2018-02-20

    This paper presents a novel hand-held photometer, termed "Photopette", for on-spot absorbance measurements of biochemical analytes. The Photopette is a multicomponent, highly portable device with an overall weight of 160 g, which fits within 202 mm × 47 mm × 42 mm. Designed in the form factor of a micropipette, Photopette integrates a photodiode detector with light emitting diodes (LEDs) to form a highly customizable photometer which supports a wide variety of applications within the wavelengths between 260 and 1050 nm. A dual-purpose disposable reflective tip was designed to act as a sample holder and a light-reflecting system, which is in stark contrast to the operation of mainstream spectrophotometers and photometers. Small volume analytes may be measured with low sample loss using this proprietary CuveTip. A user-friendly software application running on smart devices was developed to control and read the values from Photopette via a low-energy Bluetooth link. This one-step strategy allows measurements on-spot without sample transfer, minimizing cross-contamination and human error. The results reported in this paper demonstrate Photopette's great potential to quantify DNA, direct protein, and cell density directly within the laminar flow hood. Results are compared with a Nanodrop 2000c spectrophotometer, a mainstream spectrophotometer for small-volume measurements.

  17. A light/dark cycle in the NICU accelerates body weight gain and shortens time to discharge in preterm infants.

    PubMed

    Vásquez-Ruiz, Samuel; Maya-Barrios, José Alfonso; Torres-Narváez, Patricia; Vega-Martínez, Benito Rubén; Rojas-Granados, Adelina; Escobar, Carolina; Angeles-Castellanos, Manuel

    2014-09-01

    Bright constant light levels in the NICU may have negative effects on the growth and development of preterm infants The aim of this study is to evaluate the benefits of an alternating light/dark cycle in the NICU on weight gain and early discharge from the therapy in premature infants. A randomized interventional study was designed comparing infants in the NICU of Hospital Juarez de México, exposed from birth either to an LD environment (LD, n=19) or to the traditional continuous light (LL, n=19). The LD condition was achieved by placing individual removable helmets over the infant's heads. Body weight gain was analyzed, as the main indicator of stability and the main criteria for discharge in preterm infants born at 31.73±0.31week gestational age. Infants maintained in an LD cycle gained weight faster than infants in LL and therefore attained a shorter hospital stay, (34.37±3.12 vs 51.11±5.29days; P>0.01). Also, LD infants exhibited improved oxygen saturation and developed a daily melatonin rhythm. These findings provide a convenient alternative for establishing an LD environment for preterm healthy newborns in the NICU and confirm the beneficial effects of an alternating LD cycle for growth and weight gain and for earlier discharge time. Here we provide an easy and practical alternative to implement light/dark conditions in the NICU. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Effect of feeding a milk replacer to early-weaned pigs on growth, body composition, and small intestinal morphology, compared with suckled littermates.

    PubMed

    Zijlstra, R T; Whang, K Y; Easter, R A; Odle, J

    1996-12-01

    Feeding of milk replacer to early-weaned pigs was evaluated in two experiments. In Exp. 1, 18 litters of pigs were either weaned conventionally (d 21), split-weaned and fed milk replacer plus starter diet (d 14 and 21), or weaned and fed milk replacer plus starter diet (d 21). Split weaning combined with feeding a milk replacer increased ADG 22% from d 14 and d 28 compared to conventional weaning (P < .05). Feeding a milk replacer plus starter diet after weaning increased ADG 30% between d 21 and 28 compared to conventional weaning (P < .01). In Experiment 2, four litters of 12 pigs each were divided at d 18 into six heavy and six light pigs and randomized across sow-suckled, milk replacer, or starter diet groups. After 1 wk, pigs fed milk replacer weighed 20% more (P < .001), contained 10% more protein (P < .01) and 17% more fat (P < .05), and had 74% longer villi in the proximal small intestine (P < .001) than suckled pigs. In contrast, pigs fed starter diet weighed 19% less (P < .001), contained 20% less protein and fat (P < .001), and had 28% shorter villi in the proximal small intestine (P < .05) than suckled pigs. Therefore, milk replacer feeding the 1st wk after weaning stimulates pig development, both locally in the small intestine and on a whole-body basis, most likely by an increased energy and nutrient intake. Suckling beyond 18 d postnatally inhibits pigs to reach maximal potential weight gain. In conclusion, milk replacer feeding might be beneficial to reach maximal pig weight gain at weaning.

  19. Comparison of Physical and Physiological Profiles in Elite and Amateur Young Wrestlers.

    PubMed

    Demirkan, Erkan; Koz, Mitat; Kutlu, Mehmet; Favre, Mike

    2015-07-01

    The aim of this study is to examine the physical and physiological determinants of wrestling success between elite and amateur male wrestlers. The wrestlers (N = 126) were first assigned to 3 groups based on their competitive level (top elite, elite, and amateur) and then to 6 groups according to their body mass (light, middle, and heavy weight) and their competitive level (elite and amateur). Top elite and elite wrestlers had significantly (p ≤ 0.05) more training experiences and maximal oxygen uptake compared with the amateur group. In separating weight classes, light- and middle-weight elite (MWE) wrestlers had significantly (p ≤ 0.05) more training experience (7-20%) compared with the light- and middle-weight amateur (MWA) wrestlers. No significant differences were detected between elite and amateur groups (light-, middle-, and heavy-weight wrestlers) for age, body mass, height, body mass index, and body fat (p > 0.05), with the exception of height for heavy wrestlers. Leg average and peak power values (in watts and watts per kilogram) in MWE were higher than MWA (6.5 and 13%, p ≤ 0.05). Relative leg average power value in heavy-weight elite (HWE) (in watts per kilogram) was higher than heavy-weight amateur (HWA) (9.6%, p ≤ 0.05). It was seen that elite wrestlers in MWE and HWE statistically possessed a higher V̇O2max (12.5 and 11.4%, respectively) than amateur middle- and heavy-weight wrestlers (p ≤ 0.05). The results of this study suggest that training experience, aerobic endurance, and anaerobic power and capacity will give a clear advantage for the wrestlers to take part in the elite group.

  20. Three experiments to support the design of lightweight comfortable vehicle seats.

    PubMed

    Vink, P; Franz, M; Kamp, I; Zenk, R

    2012-01-01

    Seats need to be more lightweight for airplanes, cars, busses and even trains to contribute to a better environment and to reduce energy consumption. However, a reduction in comfort due to weight reduction is not preferable, which opens a new area of research: improving comfort with a minimum of material or with lightweight materials and systems. In this paper three experiments are performed to test the effects of light weight seats and parts of a seat on comfort. The first experiment shows that a new developed light weight massage system improves comfort and reduces muscle activity. The second experiment shows that the automatic seat adjustment without motors improves the comfort as well. The third experiment showed that a light weight seat following closely the human body contour is experienced on many aspects in the same way as current more heavy seats. More research and models will be needed in this ergonomic field which needs more attention.

  1. Lightweight Steel Solutions for Automotive Industry

    NASA Astrophysics Data System (ADS)

    Lee, Hong Woo; Kim, Gyosung; Park, Sung Ho

    2010-06-01

    Recently, improvement in fuel efficiency and safety has become the biggest issue in worldwide automotive industry. Although the regulation of environment and safety has been tightened up more and more, the majority of vehicle bodies are still manufactured from stamped steel components. This means that the optimized steel solutions enable to demonstrate its ability to reduce body weight with high crashworthiness performance instead of expensive light weight materials such as Al, Mg and composites. To provide the innovative steel solutions for automotive industry, POSCO has developed AHSS and its application technologies, which is directly connected to EVI activities. EVI is a technical cooperation program with customer covering all stages of new car project from design to mass production. Integrated light weight solutions through new forming technologies such as TWB, hydroforming and HPF are continuously developed and provided for EVI activities. This paper will discuss the detailed status of these technologies especially light weight steel solutions based on innovative technologies.

  2. RF beam transmission of x-band PAA system utilizing large-area, polymer-based true-time-delay module developed using imprinting and inkjet printing

    NASA Astrophysics Data System (ADS)

    Pan, Zeyu; Subbaraman, Harish; Zhang, Cheng; Li, Qiaochu; Xu, Xiaochuan; Chen, Xiangning; Zhang, Xingyu; Zou, Yi; Panday, Ashwin; Guo, L. Jay; Chen, Ray T.

    2016-02-01

    Phased-array antenna (PAA) technology plays a significant role in modern day radar and communication networks. Truetime- delay (TTD) enabled beam steering networks provide several advantages over their electronic counterparts, including squint-free beam steering, low RF loss, immunity to electromagnetic interference (EMI), and large bandwidth control of PAAs. Chip-scale and integrated TTD modules promise a miniaturized, light-weight system; however, the modules are still rigid and they require complex packaging solutions. Moreover, the total achievable time delay is still restricted by the wafer size. In this work, we propose a light-weight and large-area, true-time-delay beamforming network that can be fabricated on light-weight and flexible/rigid surfaces utilizing low-cost "printing" techniques. In order to prove the feasibility of the approach, a 2-bit thermo-optic polymer TTD network is developed using a combination of imprinting and ink-jet printing. RF beam steering of a 1×4 X-band PAA up to 60° is demonstrated. The development of such active components on large area, light-weight, and low-cost substrates promises significant improvement in size, weight, and power (SWaP) requirements over the state-of-the-art.

  3. Influence of light intensity and water content of medium on total dendrobine of Dendrobium nobile Lindl.

    PubMed

    Li, Jin-Ling; Zhao, Zhi; Liu, Hong-Chang; Luo, Chun-Li; Wang, Hua-Lei

    2017-11-01

    To ascertain the influence of light intensity and water content of medium on the total dendrobine of Dendrobium nobile (D. nobile). The principal component analysis combined with total dendrobine accumulation was conducted to assess the yield and quality of D. nobile in all treatments. In the experiment, D. nobile plants were cultivated in greenhouse as tested materials, and complete test of 9 treatments was adopted with relative light intensities 75.02%, 39.74%, 29.93% and relative water content of medium 50%, 65%, 80%. The plants were treated in June and harvested till December. Indexes including agronomic traits, fresh weight and dry weight of stem and leaf, ash content, extract, and dendrobine were measured. Under the light intensity treatments of 75.02% with 50%, 65%, 80% water content of medium, the basal stems of plants were comparatively thicker with more leaves, and the fresh weight and dry weight of stems and leaves were significantly higher than other 6 treatments. Leaves in all treatments contained dendrobine. Under the light intensity treatments of 75.02% with 50%, 65%, 80% water content of medium, dendrobine content of leaves was lower while dendrobine contents of other treatments were more than 0.60%. After comprehensive assessment through the principal component analysis and total dendrobine accumulation, the results showed that 3 treatments with relative light intensity of 75.02% ranked the top three. In brief, the moderately strong light intensity and water content of medium from low to medium can facilitate the growth and yield of D. nobile plants, while light intensity from moderately weak to weak can enhance the dendrobine content. Copyright © 2017 Hainan Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  4. Relevance of Light Spectra to Growth of the Rearing Tiger Puffer Takifugu rubripes

    PubMed Central

    Kim, Byeong-Hoon; Hur, Sung-Pyo; Hur, Sang-Woo; Lee, Chi-Hoon; Lee, Young-Don

    2016-01-01

    In fish, light (photoperiod, intensity and spectra) is main regulator in many physiological actions includinggrowth. We investigate the effect of light spectra on the somatic growth and growth-related gene expression in the rearing tiger puffer. Fish was reared under different light spectra (blue, green and red) for 8 weeks. Fish body weight and total length were promoted when reared under green light condition than red light condition. Expression of somatostatins (ss1 and ss2) in brain were showed higher expression under red light condition than green light condition. The ss3 mRNA was observed only higher expression in blue light condition. Expression of growth hormone (gh) in pituitary was detected no different levels between experimental groups. However, the fish of green light condition group was showed more high weight gain and feed efficiency than other light condition groups. Our present results suggest that somatic growth of tiger puffer is induced under green light condition because of inhibiting ss mRNA expression in brain by effect of green wavelength. PMID:27294208

  5. Portable mini-chamber for temperature dependent studies using small angle and wide angle x-ray scattering

    NASA Astrophysics Data System (ADS)

    Dev, Arun Singh; Kumar, Dileep; Potdar, Satish; Pandit, Pallavi; Roth, Stephan V.; Gupta, Ajay

    2018-04-01

    The present work describes the design and performance of a vacuum compatible portable mini chamber for temperature dependent GISAXS and GIWAXS studies of thin films and multilayer structures. The water cooled body of the chamber allows sample annealing up to 900 K using ultra high vacuum compatible (UHV) pyrolytic boron nitride heater, thus making it possible to study the temperature dependent evolution of structure and morphology of two-dimensional nanostructured materials. Due to its light weight and small size, the chamber is portable and can be accommodated at synchrotron facilities worldwide. A systematic illustration of the versatility of the chamber has been demonstrated at beamline P03, PETRA-III, DESY, Hamburg, Germany. Temperature dependent grazing incidence small angle x-ray scattering (GISAXS) and grazing incidence wide angle x-ray scattering (GIWAXS) measurements were performed on oblique angle deposited Co/Ag multilayer structure, which jointly revealed that the surface diffusion in Co columns in Co/Ag multilayer enhances by increasing temperature from RT to ˜573 K. This results in a morphology change from columnar tilted structure to densely packed morphological isotropic multilayer.

  6. 75 FR 29605 - Clean Alternative Fuel Vehicle and Engine Conversions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-26

    ... Small Volume Manufacturers and Small Volume Test Groups 1. Definition of Small Volume Manufacturers, Small Volume Test Groups, and Small Volume Engine Families a. Light-Duty and Heavy-Duty Complete... and Engines 2. Test Groups, Engine Families, and Evaporative Families a. Test Groups for Light-Duty...

  7. Associations between obesity and physical activity in dogs: a preliminary investigation.

    PubMed

    Morrison, R; Penpraze, V; Beber, A; Reilly, J J; Yam, P S

    2013-11-01

    To assess whether obesity has any association with objectively measured physical activity levels in dogs. Thirty-nine dogs wore Actigraph GT3X accelerometers (Actigraph) for 7 consecutive days. Each dog was classified as ideal weight, overweight or obese using the 5-point body condition scoring system. Total volume of physical activity and time spent in sedentary behaviour, light-moderate intensity physical activity and vigorous intensity physical activity were compared between body condition categories. Valid accelerometry data were returned for 35 of 39 dogs recruited. Eighteen dogs were classed as ideal weight, 9 as overweight and the remaining 8 as obese. All dogs spent a significant proportion of the day sedentary and obese dogs spent significantly less time in vigorous intensity physical activity than ideal weight dogs (7 ±3 minute/day versus 21 ±15 minute/day, P=0·01). Obesity is associated with lower vigorous intensity physical activity in dogs, as is also thought to occur in humans. These preliminary findings will help inform a future, larger study and may also improve our understanding of the associations between obesity and physical activity in dogs. © 2013 British Small Animal Veterinary Association.

  8. High surface area, low weight composite nickel fiber electrodes

    NASA Technical Reports Server (NTRS)

    Johnson, Bradley A.; Ferro, Richard E.; Swain, Greg M.; Tatarchuk, Bruce J.

    1993-01-01

    The energy density and power density of light weight aerospace batteries utilizing the nickel oxide electrode are often limited by the microstructures of both the collector and the resulting active deposit in/on the collector. Heretofore, these two microstructures were intimately linked to one another by the materials used to prepare the collector grid as well as the methods and conditions used to deposit the active material. Significant weight and performance advantages were demonstrated by Britton and Reid at NASA-LeRC using FIBREX nickel mats of ca. 28-32 microns diameter. Work in our laboratory investigated the potential performance advantages offered by nickel fiber composite electrodes containing a mixture of fibers as small as 2 microns diameter (Available from Memtec America Corporation). These electrode collectors possess in excess of an order of magnitude more surface area per gram of collector than FIBREX nickel. The increase in surface area of the collector roughly translates into an order of magnitude thinner layer of active material. Performance data and advantages of these thin layer structures are presented. Attributes and limitations of their electrode microstructure to independently control void volume, pore structure of the Ni(OH)2 deposition, and resulting electrical properties are discussed.

  9. Light-weight extension tubes for compressed-air garden sprayers

    Treesearch

    Thomas W. McConkey; Charles E. Swett

    1967-01-01

    To hand-spray taller trees safely and efficiently, 8-, 12-, and 16-foot extension tubes for compressed-air garden sprayers were designed and built. These light-weight tubes have been used successfully for spraying white pine leaders for weevil control on the Massabesic Experimental Forest in Maine. Bill of materials and assembly instructions are included.

  10. Peer Review of “LDT Weight Reduction Study with Crash Model, Feasibility and Detailed Cost Analyses – Chevrolet Silverado 1500 Pickup”

    EPA Science Inventory

    The contractor will conduct an independent peer review of FEV’s light-duty truck (LDT) mass safety study, “Light-Duty Vehicle Weight Reduction Study with Crash Model, Feasibility and Detailed Cost Analysis – Silverado 1500”, and its corresponding computer-aided engineering (CAE) ...

  11. Direct determination of the number-weighted mean radius and polydispersity from dynamic light-scattering data.

    PubMed

    Patty, Philipus J; Frisken, Barbara J

    2006-04-01

    We compare results for the number-weighted mean radius and polydispersity obtained either by directly fitting number distributions to dynamic light-scattering data or by converting results obtained by fitting intensity-weighted distributions. We find that results from fits using number distributions are angle independent and that converting intensity-weighted distributions is not always reliable, especially when the polydispersity of the sample is large. We compare the results of fitting symmetric and asymmetric distributions, as represented by Gaussian and Schulz distributions, respectively, to data for extruded vesicles and find that the Schulz distribution provides a better estimate of the size distribution for these samples.

  12. Mass spectrometric characterization of membrane integral low molecular weight proteins from photosystem II in barley etioplasts.

    PubMed

    Plöscher, Matthias; Granvogl, Bernhard; Zoryan, Mikael; Reisinger, Veronika; Eichacker, Lutz Andreas

    2009-02-01

    In Photosystem II (PSII), a high number of plastid encoded and membrane integral low molecular weight proteins smaller than 10 kDa, the proteins PsbE, F, H, I, J, K, L, M, N, Tc, Z and the nuclear encoded PsbW, X, Y1, Y2 proteins have been described. Here we show that all low molecular weight proteins of PSII already accumulate in the etioplast membrane fraction in darkness, whereas PsaI and PsaJ of photosystem I (PSI) represent the only low molecular weight proteins that do not accumulate in darkness. We found by BN-PAGE separation of membrane protein complexes and selective MS that the accumulation of one-helix proteins from PSII is light independent and occurs in etioplasts. In contrast, in chloroplasts isolated from light-grown plants, low molecular weight proteins were found to specifically accumulate in PSI and II complexes. Our results demonstrate how plants grown in darkness prepare for the induction of chlorophyll dependent photosystem assembly upon light perception. We anticipate that our investigation will provide the essential means for the analysis of protein assembly in any membrane utilizing low molecular weight protein subunits.

  13. Evaluation of Scheduling Methods for Multiple Runways

    NASA Technical Reports Server (NTRS)

    Bolender, Michael A.; Slater, G. L.

    1996-01-01

    Several scheduling strategies are analyzed in order to determine the most efficient means of scheduling aircraft when multiple runways are operational and the airport is operating at different utilization rates. The study compares simulation data for two and three runway scenarios to results from queuing theory for an M/D/n queue. The direction taken, however, is not to do a steady-state, or equilibrium, analysis since this is not the case during a rush period at a typical airport. Instead, a transient analysis of the delay per aircraft is performed. It is shown that the scheduling strategy that reduces the delay depends upon the density of the arrival traffic. For light traffic, scheduling aircraft to their preferred runways is sufficient; however, as the arrival rate increases, it becomes more important to separate traffic by weight class. Significant delay reduction is realized when aircraft that belong to the heavy and small weight classes are sent to separate runways with large aircraft put into the 'best' landing slot.

  14. Intrauterine Growth Restriction: Antenatal and Postnatal Aspects

    PubMed Central

    Sharma, Deepak; Shastri, Sweta; Sharma, Pradeep

    2016-01-01

    Intrauterine growth restriction (IUGR), a condition that occurs due to various reasons, is an important cause of fetal and neonatal morbidity and mortality. It has been defined as a rate of fetal growth that is less than normal in light of the growth potential of that specific infant. Usually, IUGR and small for gestational age (SGA) are used interchangeably in literature, even though there exist minute differences between them. SGA has been defined as having birth weight less than two standard deviations below the mean or less than the 10th percentile of a population-specific birth weight for specific gestational age. These infants have many acute neonatal problems that include perinatal asphyxia, hypothermia, hypoglycemia, and polycythemia. The likely long-term complications that are prone to develop when IUGR infants grow up includes growth retardation, major and subtle neurodevelopmental handicaps, and developmental origin of health and disease. In this review, we have covered various antenatal and postnatal aspects of IUGR. PMID:27441006

  15. Effect of Molecular Weight on the Ion Transport Mechanism in Polymerized Ionic Liquids

    DOE PAGES

    Fan, Fei; Wang, Weiyu; Holt, Adam P.; ...

    2016-06-07

    The unique properties of ionic liquids (ILs) have made them promising candidates for electrochemical applications. Polymerization of the corresponding ILs results in a new class of materials called polymerized ionic liquids (PolyILs). Though PolyILs offer the possibility to combine the high conductivity of ILs and the high mechanical strength of polymers, their conductivities are typically much lower than that of the corresponding small molecule ILs. In this study, seven PolyILs were synthesized having degrees of polymerization ranging from 1 to 333, corresponding to molecular weights (MW) from 482 to 160 400 g/mol. Depolarized dynamic light scattering, broadband dielectric spectroscopy, rheology,more » and differential scanning calorimetry were employed to systematically study the influence of MW on the mechanism of ionic transport and segmental dynamics in these materials. Finally, the modified Walden plot analysis reveals that the ion conductivity transforms from being closely coupled with structural relaxation to being strongly decoupled from it as MW increases.« less

  16. Combat vehicle crew helmet-mounted display: next generation high-resolution head-mounted display

    NASA Astrophysics Data System (ADS)

    Nelson, Scott A.

    1994-06-01

    The Combat Vehicle Crew Head-Mounted Display (CVC HMD) program is an ARPA-funded, US Army Natick Research, Development, and Engineering Center monitored effort to develop a high resolution, flat panel HMD for the M1 A2 Abrams main battle tank. CVC HMD is part of the ARPA High Definition Systems (HDS) thrust to develop and integrate small (24 micrometers square pels), high resolution (1280 X 1024 X 6-bit grey scale at 60 frame/sec) active matrix electroluminescent (AMEL) and active matrix liquid crystal displays (AMLCD) for head mounted and projection applications. The Honeywell designed CVC HMD is a next generation head-mounted display system that includes advanced flat panel image sources, advanced digital display driver electronics, high speed (> 1 Gbps) digital interconnect electronics, and light weight, high performance optical and mechanical designs. The resulting dramatic improvements in size, weight, power, and cost have already led to program spin offs for both military and commercial applications.

  17. Effect of Molecular Weight on the Ion Transport Mechanism in Polymerized Ionic Liquids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fan, Fei; Wang, Weiyu; Holt, Adam P.

    The unique properties of ionic liquids (ILs) have made them promising candidates for electrochemical applications. Polymerization of the corresponding ILs results in a new class of materials called polymerized ionic liquids (PolyILs). Though PolyILs offer the possibility to combine the high conductivity of ILs and the high mechanical strength of polymers, their conductivities are typically much lower than that of the corresponding small molecule ILs. In this study, seven PolyILs were synthesized having degrees of polymerization ranging from 1 to 333, corresponding to molecular weights (MW) from 482 to 160 400 g/mol. Depolarized dynamic light scattering, broadband dielectric spectroscopy, rheology,more » and differential scanning calorimetry were employed to systematically study the influence of MW on the mechanism of ionic transport and segmental dynamics in these materials. Finally, the modified Walden plot analysis reveals that the ion conductivity transforms from being closely coupled with structural relaxation to being strongly decoupled from it as MW increases.« less

  18. Analysis of reduced monoclonal antibodies using size exclusion chromatography coupled with mass spectrometry

    NASA Astrophysics Data System (ADS)

    Liu, Hongcheng; Gaza-Bulseco, Georgeen; Chumsae, Chris

    2009-12-01

    Size-exclusion chromatography (SEC) has been widely used to detect antibody aggregates, monomer, and fragments. SEC coupled to mass spectrometry has been reported to measure the molecular weights of antibody; antibody conjugates, and antibody light chain and heavy chain. In this study, separation of antibody light chain and heavy chain by SEC and direct coupling to a mass spectrometer was further studied. It was determined that employing mobile phases containing acetonitrile, trifluoroacetic acid, and formic acid allowed the separation of antibody light chain and heavy chain after reduction by SEC. In addition, this mobile phase allowed the coupling of SEC to a mass spectrometer to obtain a direct molecular weight measurement. The application of the SEC-MS method was demonstrated by the separation of the light chain and the heavy chain of multiple recombinant monoclonal antibodies. In addition, separation of a thioether linked light chain and heavy chain from the free light chain and the free heavy chain of a recombinant monoclonal antibody after reduction was also achieved. This optimized method provided a separation of antibody light chain and heavy chain based on size and allowed a direct measurement of molecular weights by mass spectrometry. In addition, this method may help to identify peaks eluting from SEC column directly.

  19. Weighted bi-prediction for light field image coding

    NASA Astrophysics Data System (ADS)

    Conti, Caroline; Nunes, Paulo; Ducla Soares, Luís.

    2017-09-01

    Light field imaging based on a single-tier camera equipped with a microlens array - also known as integral, holoscopic, and plenoptic imaging - has currently risen up as a practical and prospective approach for future visual applications and services. However, successfully deploying actual light field imaging applications and services will require developing adequate coding solutions to efficiently handle the massive amount of data involved in these systems. In this context, self-similarity compensated prediction is a non-local spatial prediction scheme based on block matching that has been shown to achieve high efficiency for light field image coding based on the High Efficiency Video Coding (HEVC) standard. As previously shown by the authors, this is possible by simply averaging two predictor blocks that are jointly estimated from a causal search window in the current frame itself, referred to as self-similarity bi-prediction. However, theoretical analyses for motion compensated bi-prediction have suggested that it is still possible to achieve further rate-distortion performance improvements by adaptively estimating the weighting coefficients of the two predictor blocks. Therefore, this paper presents a comprehensive study of the rate-distortion performance for HEVC-based light field image coding when using different sets of weighting coefficients for self-similarity bi-prediction. Experimental results demonstrate that it is possible to extend the previous theoretical conclusions to light field image coding and show that the proposed adaptive weighting coefficient selection leads to up to 5 % of bit savings compared to the previous self-similarity bi-prediction scheme.

  20. Nighttime image dehazing using local atmospheric selection rule and weighted entropy for visible-light systems

    NASA Astrophysics Data System (ADS)

    Park, Dubok; Han, David K.; Ko, Hanseok

    2017-05-01

    Optical imaging systems are often degraded by scattering due to atmospheric particles, such as haze, fog, and mist. Imaging under nighttime haze conditions may suffer especially from the glows near active light sources as well as scattering. We present a methodology for nighttime image dehazing based on an optical imaging model which accounts for varying light sources and their glow. First, glow effects are decomposed using relative smoothness. Atmospheric light is then estimated by assessing global and local atmospheric light using a local atmospheric selection rule. The transmission of light is then estimated by maximizing an objective function designed on the basis of weighted entropy. Finally, haze is removed using two estimated parameters, namely, atmospheric light and transmission. The visual and quantitative comparison of the experimental results with the results of existing state-of-the-art methods demonstrates the significance of the proposed approach.

  1. Flexible and Lightweight Fuel Cell with High Specific Power Density.

    PubMed

    Ning, Fandi; He, Xudong; Shen, Yangbin; Jin, Hehua; Li, Qingwen; Li, Da; Li, Shuping; Zhan, Yulu; Du, Ying; Jiang, Jingjing; Yang, Hui; Zhou, Xiaochun

    2017-06-27

    Flexible devices have been attracting great attention recently due to their numerous advantages. But the energy densities of current energy sources are still not high enough to support flexible devices for a satisfactory length of time. Although proton exchange membrane fuel cells (PEMFCs) do have a high-energy density, traditional PEMFCs are usually too heavy, rigid, and bulky to be used in flexible devices. In this research, we successfully invented a light and flexible air-breathing PEMFC by using a new design of PEMFC and a flexible composite electrode. The flexible air-breathing PEMFC with 1 × 1 cm 2 working area can be as light as 0.065 g and as thin as 0.22 mm. This new PEMFC exhibits an amazing specific volume power density as high as 5190 W L -1 , which is much higher than traditional (air-breathing) PEMFCs. Also outstanding is that the flexible PEMFC retains 89.1% of its original performance after being bent 600 times, and it retains its original performance after being dropped five times from a height of 30 m. Moreover, the research has demonstrated that when stacked, the flexible PEMFCs are also useful in mobile applications such as mobile phones. Therefore, our research shows that PEMFCs can be made light, flexible, and suitable for applications in flexible devices. These innovative flexible PEMFCs may also notably advance the progress in the PEMFC field, because flexible PEMFCs can achieve high specific power density with small size, small volume, low weight, and much lower cost; they are also much easier to mass produce.

  2. Bright Ideas for Measuring Light.

    ERIC Educational Resources Information Center

    Amend, John R.; Schuler, John A.

    1983-01-01

    Describes an inexpensive device (around $8.00) for measuring light. The circuit used includes five resistors, three small capacitors, a cadmium sulfide light sensor, two integrated circuits, and two light-emitting diodes. The unit is constructed on a small perforated circuit board and powered by a 9-V transistor radio battery. (JN)

  3. Tools to Perform Local Dense 3D Reconstruction of Shallow Water Seabed ‡

    PubMed Central

    Avanthey, Loïca; Beaudoin, Laurent; Gademer, Antoine; Roux, Michel

    2016-01-01

    Tasks such as distinguishing or identifying individual objects of interest require the production of dense local clouds at the scale of these individual objects of interest. Due to the physical and dynamic properties of an underwater environment, the usual dense matching algorithms must be rethought in order to be adaptive. These properties also imply that the scene must be observed at close range. Classic robotized acquisition systems are oversized for local studies in shallow water while the systematic acquisition of data is not guaranteed with divers. We address these two major issues through a multidisciplinary approach. To efficiently acquire on-demand stereoscopic pairs using simple logistics in small areas of shallow water, we devised an agile light-weight dedicated system which is easy to reproduce. To densely match two views in a reliable way, we devised a reconstruction algorithm that automatically accounts for the dynamics, variability and light absorption of the underwater environment. Field experiments in the Mediterranean Sea were used to assess the results. PMID:27196913

  4. A Si nanocube array polarizer

    NASA Astrophysics Data System (ADS)

    Chen, Linghua; Jiang, Yingjie; Xing, Li; Yao, Jun

    2017-10-01

    We have proposed a full dielectric (silicon) nanocube array polarizer based on a silicon dioxide substrate. Each polarization unit column includes a plurality of equal spaced polarization units. By optimizing the length, the width, the height of the polarization units and the center distance of adjacent polarization unit (x direction and y direction), an extinction ratio (ER) of higher than 25dB was obtained theoretically when the incident light wavelength is 1550nm. while for applications of most polarization optical elements, ER above 10dB is enough. With this condition, the polarizer we designed can work in a wide wavelength range from 1509.31nm to 1611.51nm. Compared with the previous polarizer, we have introduced a polarizer which is a full dielectric device, which solves the problems of low efficiency caused by Ohmic loss and weak coupling. Furthermore, compared with the existing optical polarizers, our polarizer has the advantages of thin thickness, small size, light weight, and low processing difficulty, which is in line with the future development trend of optical elements.

  5. Folded path LWIR system for SWAP constrained platforms

    NASA Astrophysics Data System (ADS)

    Fleet, Erin F.; Wilson, Michael L.; Linne von Berg, Dale; Giallorenzi, Thomas; Mathieu, Barry

    2014-06-01

    Folded path reflection and catadioptric optics are of growing interest, especially in the long wave infrared (LWIR), due to continuing demands for reductions in imaging system size, weight and power (SWAP). We present the optical design and laboratory data for a 50 mm focal length low f/# folded-path compact LWIR imaging system. The optical design uses 4 concentric aspheric mirrors, each of which is described by annular aspheric functions well suited to the folded path design space. The 4 mirrors are diamond turned onto two thin air-spaced aluminum plates which can be manually focused onto the uncooled LWIR microbolometer array detector. Stray light analysis will be presented to show how specialized internal baffling can be used to reduce stray light propagation through the folded path optical train. The system achieves near diffraction limited performance across the FOV with a 15 mm long optical train and a 5 mm back focal distance. The completed system is small enough to reside within a 3 inch diameter ball gimbal.

  6. Dim Light at Night Disrupts Molecular Circadian Rhythms and Affects Metabolism

    PubMed Central

    Fonken, Laura K.; Aubrecht, Taryn G.; Meléndez-Fernández, O. Hecmarie; Weil, Zachary M.; Nelson, Randy J.

    2014-01-01

    With the exception of high latitudes, life has evolved under bright days and dark nights. Most organisms have developed endogenously driven circadian rhythms which are synchronized to this daily light/dark cycle. In recent years, humans have shifted away from the naturally occurring solar light cycle in favor of artificial and sometimes irregular light schedules produced by electrical lighting. Exposure to unnatural light cycles is increasingly associated with obesity and metabolic syndrome; however the means by which environmental lighting alters metabolism are poorly understood. Thus, we exposed mice to nighttime light and investigated changes in the circadian system and body weight. Here we report that exposure to ecologically relevant levels of dim (5 lux) light at night attenuate core circadian clock rhythms in the SCN at both the gene and protein level. Moreover, circadian clock rhythms were perturbed in the liver by nighttime light exposure. Changes in the circadian clock were associated with temporal alterations in feeding behavior and increased weight gain. These results are significant because they provide mechanistic evidence for how mild changes in environmental lighting can alter circadian and metabolic function. PMID:23929553

  7. Laser profilometer module based on a low-temperature cofired ceramic substrate

    NASA Astrophysics Data System (ADS)

    Heikkinen, Veli; Heikkinen, Mikko; Keranen, Kimmo; Mitikka, Risto S.; Putila, Veli-Pekka; Tukkiniemi, Kari

    2005-09-01

    We realized a laser profilometer module using low temperature cofired ceramics technology. The device consists of a vertical-cavity surface-emitting laser as the light source and a complementary metal oxide semiconductor image sensor as the detector. The laser transmitter produces a thin light stripe on the measurable object, and the receiver calculates the distance profile using triangulation. Because the design of optoelectronic modules, such as the laser profilometer, is usually carried out using specialized software, its electronic compatibility is very important. We developed a data transmission network using commercial optical, electrical, and mechanical design software, which enabled us to electronically transfer data between the designers. The module electronics were realized with multilayer ceramics technology that eases component assembly by providing precision alignment features in the substrate. The housing was manufactured from aluminum using electronic data transfer from the mechanical design software to the five-axis milling workstation. Target distance profiles were obtained from 100 points with an accuracy varying from 0.1 mm at a 5-cm distance to 2 cm at 1.5 m. The module has potential for distance measurement in portable devices where small size, light weight, and low power consumption are important.

  8. Design of portable valuables touch alarm circuit

    NASA Astrophysics Data System (ADS)

    Li, Biqing; Li, Zhao

    2017-03-01

    In this paper, the name of the alarm is portable touch burglar alarm. It not only has the advantages of high sensitivity, small size and light weight, but it is easy on the trigger, the circuit is simple and easy to be implemented, besides, it works stably. This alarm is featured with simple design, convenient use, strong flexibility and reliable performance, thus it can be installed on the door or window and even can be carried on human's body. When the human body touches the metal valuables that need to be protected, the device will start the alarm equipment so as to make the bell keep ringing, and the alarm sound stops until the power is cut off.

  9. High-frequency imaging radar for robotic navigation and situational awareness

    NASA Astrophysics Data System (ADS)

    Thomas, David J.; Luo, Changan; Knox, Robert

    2011-05-01

    With increasingly available high frequency radar components, the practicality of imaging radar for mobile robotic applications is now practical. Navigation, ODOA, situational awareness and safety applications can be supported in small light weight packaging. Radar has the additional advantage of being able sense through aerosols, smoke and dust that can be difficult for many optical systems. The ability to directly measure the range rate of an object is also an advantage in radar applications. This paper will explore the applicability of high frequency imaging radar for mobile robotics and examine a W-band 360 degree imaging radar prototype. Indoor and outdoor performance data will be analyzed and evaluated for applicability to navigation and situational awareness.

  10. [AntiEGFRnano inhibites proliferation and migration of estrogen-dependent Ishikawa cells of human endometrial cancer cell line].

    PubMed

    Diao, Zhen-yu; Lu, Wu-guang; Cao, Peng; Hu, Yun-long; Zhou, Xing; Xue, Ping-ping; Shen, Li; Sun, Hai-xiang

    2012-10-01

    Nanobody is a kind of antibody from camel, which misses light chain. Nanobody has the same antigen binding specificity and affinity as mAb. Moreover, because of its small molecular weight, high stability and easy preparation, nanobody has great value of biomedical applications. In this study, we successfully prepared highly pure antiEGFR nanobody in E.coli using genetic engineering techniques. Cell proliferation assay (CCK-8 assay) and migration experiments (cell scratch test and Transwell assay) indicated that the recombinant antiEGFRnano can significantly inhibit the proliferation and migration of endometrial cancer cells. These results provide a new way of thinking and methods for EGFR-targeted therapy of endometrial cancer.

  11. Active Collision Avoidance for Planetary Landers

    NASA Technical Reports Server (NTRS)

    Rickman, Doug; Hannan, Mike; Srinivasan, Karthik

    2015-01-01

    The use of automotive radar systems are being evaluated for collision avoidance in planetary landers. Our focus is to develop a low-cost, light-weight collision avoidance system that overcomes the drawbacks identified with optical-based systems. We also seek to complement the Autonomous Landing and Hazard Avoidance Technology system by providing mission planners an alternative system that can be used on low-cost, small robotic missions and in close approach. Our approach takes advantage of how electromagnetic radiation interacts with solids. As the wavelength increases, the sensitivity of the radiation to isolated solids of a specific particle size decreases. Thus, rocket exhaust-blown dust particles, which have major significance in visible wavelengths, have much less significance at radar wavelengths.

  12. Scattering of hydrogen, nitrogen and water ions from micro pore optic plates for application in spaceborne plasma instrumentation

    NASA Astrophysics Data System (ADS)

    Stude, Joan; Wieser, Martin; Barabash, Stas

    2016-10-01

    Time-of-flight mass spectrometers for upcoming space missions into enhanced radiation environments need to be small, light weight and energy efficient. Time-of-flight systems using surface interactions as start-event generation can be smaller than foil-type instruments. Start surfaces for such applications need to provide narrow angular scattering, high ionization yields and high secondary electron emissions to be effective. We measured the angular scattering, energy distribution and positive ionization yield of micro pore optics for incident hydrogen, nitrogen and water ions at 2 keV. Positive ionization yields of 2% for H+ , 0.5% for N+ and 0.2% for H2O+ were detected.

  13. W-band integrated circuit PIN switches

    NASA Astrophysics Data System (ADS)

    Tahim, R. S.; Pham, T.; Chang, K.

    1986-12-01

    Both single-pole single-throw (SPST) and single-pole double-throw (SPDT) PIN switches have been developed at W band using microstrip integrated circuits. In SPST configurations, these switches have less than 1 dB of insertion loss under forward-voltage conditions from 90 to 108 GHz. Isolation greater than 20 dB over 3 GHz and greater than 10 dB over 7 GHz has been achieved. In SPDT configurations, insertion loss of less than 2 dB and isolation of more than 15 dB over 10 GHz (90 to 110 GHz) have been achieved. Beam-lead PIN diodes were used. Major features included mechanical ruggedness, light weight, small size and low-cost manufacturing.

  14. SDSS-IV MaNGA: Spatially resolved star formation histories in galaxies as a function of galaxy mass and type

    NASA Astrophysics Data System (ADS)

    Goddard, D.; Thomas, D.; Maraston, C.; Westfall, K.; Etherington, J.; Riffel, R.; Mallmann, N. D.; Zheng, Z.; Argudo-Fernández, M.; Lian, J.; Bershady, M.; Bundy, K.; Drory, N.; Law, D.; Yan, R.; Wake, D.; Weijmans, A.; Bizyaev, D.; Brownstein, J.; Lane, R. R.; Maiolino, R.; Masters, K.; Merrifield, M.; Nitschelm, C.; Pan, K.; Roman-Lopes, A.; Storchi-Bergmann, T.; Schneider, D. P.

    2017-04-01

    We study the internal gradients of stellar population properties within 1.5 Re for a representative sample of 721 galaxies, with stellar masses ranging between 109 M⊙ and 1011.5 M⊙ from the SDSS-IV MaNGA Integral-Field-Unit survey. Through the use of our full spectral fitting code firefly, we derive light- and mass-weighted stellar population properties and their radial gradients, as well as full star formation and metal enrichment histories. We also quantify the impact that different stellar population models and full spectral fitting routines have on the derived stellar population properties and the radial gradient measurements. In our analysis, we find that age gradients tend to be shallow for both early-type and late-type galaxies. Mass-weighted age gradients of early-types arepositive (˜0.09 dex/Re) pointing to 'outside-in' progression of star formation, while late-type galaxies have negative light-weighted age gradients (˜-0.11 dex/Re), suggesting an 'inside-out' formation of discs. We detect negative metallicity gradients in both early- and late-type galaxies, but these are significantly steeper in late-types, suggesting that the radial dependence of chemical enrichment processes and the effect of gas inflow and metal transport are far more pronounced in discs. Metallicity gradients of both morphological classes correlate with galaxy mass, with negative metallicity gradients becoming steeper with increasing galaxy mass. The correlation with mass is stronger for late-type galaxies, with a slope of d(∇[Z/H])/d(log M) ˜ -0.2 ± 0.05 , compared to d(∇[Z/H])/d(log M) ˜ -0.05 ± 0.05 for early-types. This result suggests that the merger history plays a relatively small role in shaping metallicity gradients of galaxies.

  15. Effect of supplemental light on growth, prolactin, progesterone and luteinizing hormone in water buffalo ( Bubalus bubalis)

    NASA Astrophysics Data System (ADS)

    Perera, K. S.; Gwazdauskas, F. C.; Akers, R. M.; McGilliard, M. L.

    1989-06-01

    Fifty non-pregnant Surti buffalo heifers aged between 17 and 42 months ( n=24, <24 months; n=26, >24 months) were randomly assigned to groups subject to either natural daylight +4h supplemental light ( n=25) or natural day light ( n=25), to study changes in growth, serum prolactin (Prl), progesterone (P4) and luteinizing hormone (LH) to supplemental lighting. Ambient temperatures (T) and relative humidity (RH) generally were >27° C and <70% during the day-time, respectively. Light-supplemented heifers had 16.2 kg net body weight (BW) gain at 9 weeks compared to 20.8 kg for controls, but higher mean Prl after 6.5 weeks ( P<0.01), and higher P4 (0.41 vs 0.19 ng/ml; P<0.06) than control heifers. Older heifers had 39.7% greater BW ( P<0.01), but a net 4.3% BW gain compared to a 10.1% gain for younger heifers at 10 weeks. Older, light-supplemented heifers had higher mean P4 (0.63 vs 0.19 ng/ml; P<0.07) than the other groups. These weight and hormonal changes suggest that 4 h supplemental light can alter growth and endocrine function in buffaloes under similar planes of nutrition. While light supplementation did not have a positive effect on body wieght during the 10 week study, body weight and endocrine changes due to supplemental light may be important factors for initiation of reproductive cyclicity.

  16. The influence of parenting style on health related behavior of children: findings from the ChiBS study

    PubMed Central

    2014-01-01

    Objective Exploring associations between parenting behavior and children’s health related behavior including physical activity, sedentary behavior, diet and sleep. Methods We recruited 288 parents and their children (6-12y old). Children’s weight and height were measured. Fat percentage was determined by air displacement plethysmography. Parents reported socio-demographic data, sleep information, physical activity and sedentary behavior of their child and completed the Comprehensive General Parenting Questionnaire (CGPQ) and a Food Frequency Questionnaire. Children completed the Dutch Eating Behavior Questionnaire. Associations between parenting behavior (CGPQ) and children’s health related behavior were assessed with univariate and multiple regression analyses. Results A small positive correlation was found between sweet food consumption frequency and “coercive control” (r = 0.139) and a small negative correlation between fruit and vegetables consumption frequency and “overprotection” (r = −0.151). Children consumed more frequently soft drinks when their parents scored lower on “structure” (r = −0.124) and higher on “overprotection” (r = 0.123); for the light soft drinks separately, a small positive correlation with “behavioral control” was found (r = 0.172). A small negative correlation was found between “emotional eating” and “structure” (r = −0.172) as well as “behavioral control” (r = −0.166). “Coercive control” was negatively correlated with the child’s sleep duration (r = −0.171). After correction for confounding factors, the following significant associations were found: (1) a small negative association between “structure” and soft drinks consumption (β = −0.17 for all soft drinks and −0.22 for light soft drinks), (2) a small positive association between “behavioral control” and light soft drinks (β = 0.34), (3) a small positive association of “nurturance” and “coercive control” with sedentary behavior (β = 0.16 for both parent constructs) and (4) a small negative association between the parenting construct “coercive control” and sleep duration (β = −0.23). Conclusion The significant but small associations between parenting constructs and the investigated variables suggest that different aspects of parenting style play an important role in the genesis of the health related behavior of children. Overall, our findings suggest that health professionals should encourage parents to apply the more positive parenting constructs i.e., more “structure” and “behavioral control”, and less “coercive control”. They could, for instance, supervise and manage their child’s activities and help their child to achieve certain goals. PMID:25052905

  17. Light-intensity and high-intensity interval training improve cardiometabolic health in rats.

    PubMed

    Batacan, Romeo B; Duncan, Mitch J; Dalbo, Vincent J; Connolly, Kylie J; Fenning, Andrew S

    2016-09-01

    Physical activity has the potential to reduce cardiometabolic risk factors but evaluation of different intensities of physical activity and the mechanisms behind their health effects still need to be fully established. This study examined the effects of sedentary behaviour, light-intensity training, and high-intensity interval training on biometric indices, glucose and lipid metabolism, inflammatory and oxidative stress markers, and vascular and cardiac function in adult rats. Rats (12 weeks old) were randomly assigned to 1 of 4 groups: control (CTL; no exercise), sedentary (SED; no exercise and housed in small cages to reduce activity), light-intensity trained (LIT; four 30-min exercise bouts/day at 8 m/min separated by 2-h rest period, 5 days/week), and high-intensity interval trained (HIIT, four 2.5-min work bouts/day at 50 m/min separated by 3-min rest periods, 5 days/week). After 12 weeks of intervention, SED had greater visceral fat accumulation (p < 0.01) and slower cardiac conduction (p = 0.04) compared with the CTL group. LIT and HIIT demonstrated beneficial changes in body weight, visceral and epididymal fat weight, glucose regulation, low-density lipoprotein cholesterol, total cholesterol, and mesenteric vessel contractile response compared with the CTL group (p < 0.05). LIT had significant improvements in insulin sensitivity and cardiac conduction compared with the CTL and SED groups whilst HIIT had significant improvements in systolic blood pressure and endothelium-independent vasodilation to aorta and mesenteric artery compared with the CTL group (p < 0.05). LIT and HIIT induce health benefits by improving traditional cardiometabolic risk factors. LIT improves cardiac health while HIIT promotes improvements in vascular health.

  18. The Nano-X Linear Accelerator: A Compact and Economical Cancer Radiotherapy System Incorporating Patient Rotation.

    PubMed

    Eslick, Enid M; Keall, Paul J

    2015-10-01

    Rapid technological improvements in radiotherapy delivery results in improved outcomes to patients, yet current commercial systems with these technologies on board are costly. The aim of this study was to develop a state-of-the-art cancer radiotherapy system that is economical and space efficient fitting with current world demands. The Nano-X system is a compact design that is light weight combining a patient rotation system with a vertical 6 MV fixed beam. In this paper, we present the Nano-X system design configuration, an estimate of the system dimensions and its potential impact on shielding cost reductions. We provide an assessment of implementing such a radiotherapy system clinically, its advantages and disadvantages compared to a compact conventional gantry rotating linac. The Nano-X system has several differentiating features from current radiotherapy systems, it is [1] compact and therefore can fit into small vaults, [2] light weight, and [3] engineering efficient, i.e., it rotates a relatively light component and the main treatment delivery components are not under rotation (e.g., DMLCs). All these features can have an impact on reducing the costs of the system. In terms of shielding requirements, leakage radiation was found to be the dominant contributor to the Nano-X vault and as such no primary shielding was necessary. For a low leakage design, the Nano-X vault footprint and concrete volume required is 17 m2 and 35 m3 respectively, compared to 54 m2 and 102 m3 for a conventional compact linac vault, resulting in decreased costs in shielding. Key issues to be investigated in future work are the possible patient comfort concerns associated with the patient rotation system, as well as the magnitude of deformation and subsequent adaptation requirements. © The Author(s) 2014.

  19. Stimulation with monochromatic green light during incubation alters satellite cell mitotic activity and gene expression in relation to embryonic and posthatch muscle growth of broiler chickens.

    PubMed

    Zhang, L; Zhang, H J; Wang, J; Wu, S G; Qiao, X; Yue, H Y; Yao, J H; Qi, G H

    2014-01-01

    Previous studies showed that monochromatic green light stimuli during embryogenesis accelerated posthatch body weight (BW) and pectoral muscle growth of broilers. In this experiment, we further investigated the morphological and molecular basis of this phenomenon. Fertile broiler eggs (Arbor Acres, n=880) were pre-weighed and randomly assigned to 1 of the 2 incubation treatment groups: (1) dark condition (control group), and (2) monochromatic green light group (560 nm). The monochromatic lighting systems sourced from light-emitting diode lamps and were equalized at the intensity of 15 lx at eggshell level. The dark condition was set as a commercial control from day 1 until hatching. After hatch, 120 male 1-day-old chicks from each group were housed under incandescent white light with an intensity of 30 lx at bird-head level. No effects of light stimuli during embryogenesis on hatching time, hatchability, hatching weight and bird mortality during the feeding trial period were observed in the present study. Compared with the dark condition, the BW, pectoral muscle weight and myofiber cross-sectional areas were significantly greater on 7-day-old chicks incubated under green light. Green light also increased the satellite cell mitotic activity of pectoral muscle on 1- and 3-day-old birds. In addition, green light upregulated MyoD, myogenin and myostatin mRNA expression in late embryos and/ or newly hatched chicks. These data suggest that stimulation with monochromatic green light during incubation promote muscle growth by enhancing proliferation and differentiation of satellite cells in late embryonic and newly hatched stages. Higher expression of myostatin may ultimately help prevent excessive proliferation and differentiation of satellite cells in birds incubated under green light.

  20. Effect of varying light intensity on growth performance and carcass characteristics of broiler chickens grown to heavy weights

    USDA-ARS?s Scientific Manuscript database

    This study investigated effects of varying levels of light intensities (25, 10, 5, 2.5, and 0.2 lx) on growth performance and carcass characteristics of broiler chickens grown to heavy weights. Four identical trials were conducted with two replications per trial. In each trial, 600 1-d-old Ross 308 ...

  1. Effects of body weight on antibody titers against canine parvovirus type 2, canine distemper virus, and canine adenovirus type 1 in vaccinated domestic adult dogs.

    PubMed

    Taguchi, Masayuki; Namikawa, Kazuhiko; Maruo, Takuya; Saito, Miyoko; Lynch, Jonathan; Sahara, Hiroeki

    2012-10-01

    The objective of this study was to determine whether post-vaccination antibody titers vary according to body weight in adult dogs. Antibody titers against canine parvovirus type 2 (CPV-2), canine distemper virus (CDV), and canine adenovirus type 1 (CAdV-1) were measured for 978 domestic adult dogs from 2 to 6 y of age. The dogs had been vaccinated approximately 12 mo earlier with a commercial combination vaccine. The dogs were divided into groups according to their weight. It was found that mean antibody titers in all weight groups were sufficient to prevent infection. Intergroup comparison, however, revealed that CPV-2 antibody titers were significantly higher in the Super Light (< 5 kg) group than in the Medium (10 to 19.9 kg) and Heavy (> 20 kg) groups and were also significantly higher in the Light (5 to 9.9 kg) group than in the Heavy group. Antibody titers against CDV were significantly higher in the Super Light, Light, and Medium groups than in the Heavy group. There were no significant differences among the groups for the CAdV-1 antibody titers.

  2. Thermal properties of light-weight concrete with waste polypropylene aggregate

    NASA Astrophysics Data System (ADS)

    Záleská, Martina; Pokorný, Jaroslav; Pavlíková, Milena; Pavlík, Zbyšek

    2017-07-01

    Thermal properties of a sustainable light-weight concrete incorporating high volume of waste polypropylene as partial substitution of natural aggregate were studied in the paper. Glass fiber reinforced polypropylene (GFPP), a by-product of PP tubes production, partially substituted fine natural silica aggregate in 10, 20, 30, 40, and 50 mass%. In order to quantify the effect of GFPP use on concrete properties, a reference concrete mix without plastic waste was studied as well. For the applied GFPP, bulk density, matrix density, and particle size distribution were measured. Specific attention was paid to thermal transport and storage properties of GFPP that were examined in dependence on compaction time. For the developed light-weight concrete, thermal properties were accessed using transient impulse technique, whereas the measurement was done in dependence on moisture content, from the dry state to fully water saturated state. Additionally, the investigated thermal properties were plotted as function of porosity. The tested light-weight concrete was found to be prospective construction material possessing improved thermal insulation function. Moreover, the reuse of waste plastics in concrete composition was beneficial both from the environmental and financial point of view considering plastics low biodegradability and safe disposal.

  3. Changes in Light Absorptivity of Molecular Weight Separated Brown Carbon Due to Photolytic Aging.

    PubMed

    Wong, Jenny P S; Nenes, Athanasios; Weber, Rodney J

    2017-08-01

    Brown carbon (BrC) consists of those organic compounds in atmospheric aerosols that absorb solar radiation and may play an important role in planetary radiative forcing and climate. However, little is known about the production and loss mechanisms of BrC in the atmosphere. Here, we study how the light absorptivity of BrC from wood smoke and secondary BrC generated from the reaction of ammonium sulfate with methylglyoxal changes under photolytic aging by UVA radiation in the aqueous phase. Owing to its chemical complexity, BrC is separated by molecular weight using size exclusion chromatography, and the response of each molecular weight fraction to aging is studied. Photolytic aging induced significant changes in the light absorptivity of BrC for all molecular weight fractions; secondary BrC was rapidly photoblenched, whereas for wood smoke BrC, both photoenhancement and photobleaching were observed. Initially, large biomass burning BrC molecules were rapidly photoenhanced, followed by slow photolysis. As a result, large BrC molecules dominated the total light absorption of aged biomass burning BrC. These experimental results further support earlier observations that large molecular weight BrC compounds from biomass burning can be relatively long-lived components in atmospheric aerosols, thus more likely to have larger impacts on aerosol radiative forcing and could serve as biomass burning tracers.

  4. Gradient Weight in Phonology

    ERIC Educational Resources Information Center

    Ryan, Kevin Michael

    2011-01-01

    Research on syllable weight in generative phonology has focused almost exclusively on systems in which weight is treated as an ordinal hierarchy of clearly delineated categories (e.g. light and heavy). As I discuss, canonical weight-sensitive phenomena in phonology, including quantitative meter and quantity-sensitive stress, can also treat weight…

  5. Molecular Weight and Molecular Weight Distributions in Synthetic Polymers.

    ERIC Educational Resources Information Center

    Ward, Thomas Carl

    1981-01-01

    Focuses on molecular weight and molecular weight distributions (MWD) and models for predicting MWD in a pedagogical way. In addition, instrumental methods used to characterize MWD are reviewed with emphasis on physical chemistry of each, including end-group determination, osmometry, light scattering, solution viscosity, fractionation, and…

  6. How Much Weight to Use During Strength Training Activities

    Cancer.gov

    Many women want to start a strength training routine but aren’t sure how much weight to use. Start with resistance bands, soup cans, or light weights (1 to 3 pounds) and build up to tighter bands or heavier weights as you feel and become stronger.

  7. Improving spinach, radish, and lettuce growth under red light-emitting diodes (LEDs) with blue light supplementation

    NASA Technical Reports Server (NTRS)

    Yorio, N. C.; Goins, G. D.; Kagie, H. R.; Wheeler, R. M.; Sager, J. C.

    2001-01-01

    Radish (Raphanus sativus L. cv. Cherriette), lettuce (Lactuca sativa L. cv. Waldmann's Green), and spinach (Spinacea oleracea L. cv. Nordic IV) plants were grown under 660-nm red light-emitting diodes (LEDs) and were compared at equal photosynthetic photon flux (PPF) with either plants grown under cool-white fluorescent lamps (CWF) or red LEDs supplemented with 10% (30 micromoles m-2 s-1) blue light (400-500 nm) from blue fluorescent (BF) lamps. At 21 days after planting (DAP), leaf photosynthetic rates and stomatal conductance were greater for plants grown under CWF light than for those grown under red LEDs, with or without supplemental blue light. At harvest (21 DAP), total dry-weight accumulation was significantly lower for all species tested when grown under red LEDs alone than when grown under CWF light or red LEDs + 10% BF light. Moreover, total dry weight for radish and spinach was significantly lower under red LEDs + 10% BF than under CWF light, suggesting that addition of blue light to the red LEDs was still insufficient for achieving maximal growth for these crops.

  8. Light Duty Truck Weight Reduction Evaluation

    DOT National Transportation Integrated Search

    1980-10-01

    The objectives of this program were to identify the weight reduction potential of pickup trucks, vans, and utility vehicles less than or equal to 8500 lb. gross vehicle weight through design modification, redesign, and material substitution; and more...

  9. Lightweight Steel Solutions for Automotive Industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Hong Woo; Kim, Gyosung; Park, Sung Ho

    2010-06-15

    Recently, improvement in fuel efficiency and safety has become the biggest issue in worldwide automotive industry. Although the regulation of environment and safety has been tightened up more and more, the majority of vehicle bodies are still manufactured from stamped steel components. This means that the optimized steel solutions enable to demonstrate its ability to reduce body weight with high crashworthiness performance instead of expensive light weight materials such as Al, Mg and composites. To provide the innovative steel solutions for automotive industry, POSCO has developed AHSS and its application technologies, which is directly connected to EVI activities. EVI ismore » a technical cooperation program with customer covering all stages of new car project from design to mass production. Integrated light weight solutions through new forming technologies such as TWB, hydroforming and HPF are continuously developed and provided for EVI activities. This paper will discuss the detailed status of these technologies especially light weight steel solutions based on innovative technologies.« less

  10. Optical implementation of inner product neural associative memory

    NASA Technical Reports Server (NTRS)

    Liu, Hua-Kuang (Inventor)

    1995-01-01

    An optical implementation of an inner-product neural associative memory is realized with a first spatial light modulator for entering an initial two-dimensional N-tuple vector and for entering a thresholded output vector image after each iteration until convergence is reached, and a second spatial light modulator for entering M weighted vectors of inner-product scalars multiplied with each of the M stored vectors, where the inner-product scalars are produced by multiplication of the initial input vector in the first iterative cycle (and thresholded vectors in subsequent iterative cycles) with each of the M stored vectors, and the weighted vectors are produced by multiplication of the scalars with corresponding ones of the stored vectors. A Hughes liquid crystal light valve is used for the dual function of summing the weighted vectors and thresholding the sum vector. The thresholded vector is then entered through the first spatial light modulator for reiteration of the process cycle until convergence is reached.

  11. The influence of car-seat design on its character experience.

    PubMed

    Kamp, Irene

    2012-03-01

    Producing higher efficiency cars with less and lighter materials but without compromising safety, comfort and driving pleasure might give a competitive advantage. In this light, at BMW a new light weight car-seat concept was developed based on the human body contour. A possibility to increase the comfort is using a seat which elicits positive tactile experiences. However, limited information is available on seat characteristics and tactile experiences. Therefore, this study describes the contour of three different car-seat designs, including a light weight seat, and the recorded corresponding emotion and tactile experience of 21 persons sitting in the seats. Results show that the new light weight car-seat concept rated well on experienced relaxedness, even with the lack of a side support. The most important findings are that hard seats with rather high side supports are rated sporty and seats that are softer are rated more luxurious. Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  12. Development and system identification of a light unmanned aircraft for flying qualities research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peters, M.E.; Andrisani, D. II

    This paper describes the design, construction, flight testing and system identification of a light weight remotely piloted aircraft and its use in studying flying qualities in the longitudinal axis. The short period approximation to the longitudinal dynamics of the aircraft was used. Parameters in this model were determined a priori using various empirical estimators. These parameters were then estimated from flight data using a maximum likelihood parameter identification method. A comparison of the parameter values revealed that the stability derivatives obtained from the empirical estimators were reasonably close to the flight test results. However, the control derivatives determined by themore » empirical estimators were too large by a factor of two. The aircraft was also flown to determine how the longitudinal flying qualities of light weight remotely piloted aircraft compared to full size manned aircraft. It was shown that light weight remotely piloted aircraft require much faster short period dynamics to achieve level I flying qualities in an up-and-away flight task.« less

  13. Shedding Some Light.

    ERIC Educational Resources Information Center

    Whitney, Tim

    1998-01-01

    Discusses the basics of designing natural and artificial light in an indoor athletic facility. Also examines individual lighting requirements of typical rooms such as weight and fitness rooms, aerobics and multipurpose rooms, gymnasiums, field houses, pools, and racquetball and squash courts. (GR)

  14. Monolithic integrated optic fiber Bragg grating sensor interrogator

    NASA Astrophysics Data System (ADS)

    Mendoza, Edgar A.; Esterkin, Yan; Kempen, Cornelia; Sun, Songjian

    2010-04-01

    Fiber Bragg gratings (FBGs) are a mature sensing technology that has gained rapid acceptance in civil, aerospace, chemical and petrochemical, medicine, aviation and automotive industries. Fiber Bragg grating sensors can be use for a variety of measurements including strain, stress, vibration, acoustics, acceleration, pressure, temperature, moisture, and corrosion distributed at multiple locations within the structure using a single fiber element. The most prominent advantages of FBGs are: small size and light weight, multiple FBG transducers on a single fiber, and immunity to radio frequency interference. A major disadvantage of FBG technology is that conventional state-of-the-art fiber Bragg grating interrogation systems are typically bulky, heavy, and costly bench top instruments that are assembled from off-the-shelf fiber optic and optical components integrated with a signal electronics board into an instrument console. Based on the need for a compact FBG interrogation system, this paper describes recent progress towards the development of a miniature fiber Bragg grating sensor interrogator (FBG-TransceiverTM) system based on multi-channel monolithic integrated optic sensor microchip technology. The integrated optic microchip technology enables the monolithic integration of all of the functionalities, both passive and active, of conventional bench top FBG sensor interrogators systems, packaged in a miniaturized, low power operation, 2-cm x 5-cm small form factor (SFF) package suitable for the long-term structural health monitoring in applications where size, weight, and power are critical for operation.

  15. Liquid crystalline phases in suspensions of pigments in non-polar solvents

    NASA Astrophysics Data System (ADS)

    Klein, Susanne; Richardson, Robert M.; Eremin, Alexey

    We will discuss colloid suspensions of pigments and compare their electro-optic properties with those of traditional dyed low molecular weight liquid crystal systems. There are several potential advantages of colloidal suspensions over low molecular weight liquid crystal systems: a very high contrast because of the high orientational order parameter of suspensions of rod shaped nano-particles, the excellent light fastness of pigments as compared to dyes and high colour saturations resulting from the high loading of the colour stuff. Although a weak `single-particle' electro-optic response can be observed in dilute suspensions, the response is very much enhanced when the concentration of the particles is sufficient to lead to a nematic phase. Excellent stability of suspensions is beneficial for experimental observation and reproducibility, but it is a fundamental necessity for display applications. We therefore discuss a method to achieve long term stability of dispersed pigments and the reasons for its success. Small angle X-ray scattering was used to determine the orientational order parameter of the suspensions as a function of concentration and the dynamic response to an applied electric field. Optical properties were investigated for a wide range of pigment concentrations. Electro-optical phenomena, such as field-induced birefringence and switching, were characterised. In addition, mixtures of pigment suspensions with small amounts of ferrofluids show promise as future magneto-optical materials.

  16. Light focusing through a multiple scattering medium: ab initio computer simulation

    NASA Astrophysics Data System (ADS)

    Danko, Oleksandr; Danko, Volodymyr; Kovalenko, Andrey

    2018-01-01

    The present study considers ab initio computer simulation of the light focusing through a complex scattering medium. The focusing is performed by shaping the incident light beam in order to obtain a small focused spot on the opposite side of the scattering layer. MSTM software (Auburn University) is used to simulate the propagation of an arbitrary monochromatic Gaussian beam and obtain 2D distribution of the optical field in the selected plane of the investigated volume. Based on the set of incident and scattered fields, the pair of right and left eigen bases and corresponding singular values were calculated. The pair of right and left eigen modes together with the corresponding singular value constitute the transmittance eigen channel of the disordered media. Thus, the scattering process is described in three steps: 1) initial field decomposition in the right eigen basis; 2) scaling of decomposition coefficients for the corresponding singular values; 3) assembling of the scattered field as the composition of the weighted left eigen modes. Basis fields are represented as a linear combination of the original Gaussian beams and scattered fields. It was demonstrated that 60 independent control channels provide focusing the light into a spot with the minimal radius of approximately 0.4 μm at half maximum. The intensity enhancement in the focal plane was equal to 68 that coincided with theoretical prediction.

  17. Compact reflective imaging spectrometer utilizing immersed gratings

    DOEpatents

    Chrisp, Michael P [Danville, CA

    2006-05-09

    A compact imaging spectrometer comprising an entrance slit for directing light, a first mirror that receives said light and reflects said light, an immersive diffraction grating that diffracts said light, a second mirror that focuses said light, and a detector array that receives said focused light. The compact imaging spectrometer can be utilized for remote sensing imaging spectrometers where size and weight are of primary importance.

  18. Big Effect of Small Nanoparticles: A Shift in Paradigm for Polymer Nanocomposites

    DOE PAGES

    Cheng, Shiwang; Xie, Shi-Jie; Carrillo, Jan-Michael Y.; ...

    2017-01-04

    Polymer nanocomposites (PNCs) are important materials that are widely used in many current technologies and potentially have broader applications in the future due to their excellent property of tunability, light weight and low cost. But, expanding the limits in property enhancement remains a fundamental scientific challenge. We demonstrate that well-dispersed, small (diameter ~1.8 nm) nanoparticles with attractive interactions lead to unexpectedly large and qualitatively new changes in PNC structural dynamics in comparison to conventional composites based on particles of diameter ~10-50 nm. At the same time, the zero-shear viscosity at high temperatures remains comparable to that of the neat polymer,more » thereby retaining good processibility and resolving a major challenge in PNC applications. These results suggest that the nanoparticle mobility and relatively short lifetimes of nanoparticlepolymer associations open qualitatively new horizons in tunability of macroscopic properties in nanocomposites with high potential for the development of new functional materials.« less

  19. Isolation and initial structural characterization of a 27 kDa protein from Zingiber officinale

    NASA Astrophysics Data System (ADS)

    Rasheed, Saima; Malik, Shoaib Ahmad; Falke, Sven; Arslan, Ali; Fazel, Ramin; Schlüter, Hartmut; Betzel, Christian; Choudhary, M. Iqbal

    2018-03-01

    Zingiber officinale Roscoe (Ginger) is a widely used traditional medicinal plant (for different ailments such as arthritis, constipation, and hypertension). This article describes the isolation and characterization of a so far unknown protein from ginger rhizomes applying ion exchange, affinity, size-exclusion chromatography, small angle X-ray scattering (SAXS), and mass spectrometry techniques. One-dimensional Coomassie-stained SDS-PAGE was performed under non-reducing conditions, showing one band corresponding to approx. 27 kDa. Dynamic light scattering (DLS) analysis of the protein solution revealed monodispersity and a monomeric state of the purified protein. Circular dichroism (CD) spectroscopy strongly indicated a β-sheet-rich protein, and disordered regions. MALDI-TOF-MS, and LC-MS/MS analysis resulted in the identification of 27.29 kDa protein, having 32.13% and 25.34% sequence coverage with Zingipain-1 and 2, respectively. The monomeric state and molecular weight were verified by small angle X-ray scattering (SAXS) studies. An elongated ab-initio model was calculated based on the scattering intensity distribution.

  20. Report on monitoring and support instruments for solar physics research from Spacelab

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The Quick Reaction and Special Purpose Facility Definition Team for Solar Physics Spacelab Payloads examined a variety of instruments to fulfill the following functions: (1) solar physics research appropriate to Spacelab, (2) correlative data for research in such fields as aeronomy, magnetospheric physics, ionospheric physics, meteorology and climatology, (3) target selection for activity alert monitoring and (4) pointing accuracy monitoring of Spacelab platforms. In this examination the team accepted a number of restrictions and qualifications: (1) the cost of such instruments must be low, so as not to adversely impact the development of new, research class instrumentation in the early Spacelab era; (2) the instruments should be of such a size that they each would occupy a small fraction of a pointing system, and (3) the weight and power consumption of the instruments should also be small. With these restrictions, the instruments chosen are: the visible light telescope and magnetograph, the extreme-ultraviolet telescope, and the solar irradiance monitor.

  1. Stabilizing Off-pathway Oligomers by Polyphenol Nanoassemblies for IAPP Aggregation Inhibition

    NASA Astrophysics Data System (ADS)

    Nedumpully-Govindan, Praveen; Kakinen, Aleksandr; Pilkington, Emily H.; Davis, Thomas P.; Chun Ke, Pu; Ding, Feng

    2016-01-01

    Experimental studies have shown that many naturally occurring polyphenols have inhibitory effect on the aggregation of several proteins. Here, we use discrete molecular dynamics (DMD) simulations and high-throughput dynamic light scattering (DLS) experiments to study the anti-aggregation effects of two polyphenols, curcumin and resveratrol, on the aggregation of islet amyloid polypeptide (IAPP or amylin). Our DMD simulations suggest that the aggregation inhibition is caused by stabilization of small molecular weight IAPP off-pathway oligomers by the polyphenols. Our analysis indicates that IAPP-polyphenol hydrogen bonds and π-π stacking combined with hydrophobic interactions are responsible for the stabilization of oligomers. The presence of small oligomers is confirmed with DLS measurements in which nanometer-sized oligomers are found to be stable for up to 7.5 hours, the time frame within which IAPP aggregates in the absence of polyphenols. Our study offers a general anti-aggregation mechanism for polyphenols, and further provides a computational framework for the future design of anti-amyloid aggregation therapeutics.

  2. Holographic gunsights for small arms

    NASA Astrophysics Data System (ADS)

    Tai, Anthony M.; Sieczka, Eric J.; Radler, Richard; Upatnieks, Juris

    1996-05-01

    Holographic gunsights were first demonstrated in the mid 1970s by researchers at the Environmental Research Institute of Michigan (ERIM) under contracts with the Air Force and the Army. The sights utilized He-Ne gas lasers and were designed for use with large weapons systems. With the advent of low cost visible laser diode, ERIM formed a new company, EOTech, to develop, manufacture and market a holographic gun sight for small arms. A hologram is used to reconstruct the image of a reticle pattern that appears at the target plane. Unlike red-dot sights, virtually any reticle pattern, 2D or 3D, can be formed. The design challenges include an opto-mechanical package that is compact, light weight and low cost which can withstand recoils up to 4,000 Gs and provide fine elevation/windage pointing adjustments, and optics that are aberration-free and stable over a wide temperature range. Manufacturing challenges include the mass production of high quality holographic optics at low cost and the precision alignment of the very low f/number optics.

  3. A tuneable approach to uniform light distribution for artificial daylight photodynamic therapy.

    PubMed

    O'Mahoney, Paul; Haigh, Neil; Wood, Kenny; Brown, C Tom A; Ibbotson, Sally; Eadie, Ewan

    2018-06-16

    Implementation of daylight photodynamic therapy (dPDT) is somewhat limited by variable weather conditions. Light sources have been employed to provide artificial dPDT indoors, with low irradiances and longer treatment times. Uniform light distribution across the target area is key to ensuring effective treatment, particularly for large areas. A novel light source is developed with tuneable direction of light emission in order to meet this challenge. Wavelength composition of the novel light source is controlled such that the protoporphyrin-IX (PpIX) weighed spectra of both the light source and daylight match. The uniformity of the light source is characterised on a flat surface, a model head and a model leg. For context, a typical conventional PDT light source is also characterised. Additionally, the wavelength uniformity across the treatment site is characterised. The PpIX-weighted spectrum of the novel light source matches with PpIX-weighted daylight spectrum, with irradiance values within the bounds for effective dPDT. By tuning the direction of light emission, improvements are seen in the uniformity across large anatomical surfaces. Wavelength uniformity is discussed. We have developed a light source that addresses the challenges in uniform, multiwavelength light distribution for large area artificial dPDT across curved anatomical surfaces. Copyright © 2018. Published by Elsevier B.V.

  4. The weight of time: affordances for an integrated magnitude system.

    PubMed

    Lu, Aitao; Mo, Lei; Hodges, Bert H

    2011-12-01

    In five experiments we explored the effects of weight on time in different action contexts to test the hypothesis that an integrated magnitude system is tuned to affordances. Larger magnitudes generally seem longer; however, Lu and colleagues (2009) found that if numbers were presented as weights in a range heavy enough to affect lifting, the "larger seems longer" effect was enhanced, but it was eliminated with weights too light to affect lifting. Experiments 1 and 2 revealed that actually lifting kilogram and gram weights had effects parallel to symbolized weights, suggesting that Lu et al.'s task implicitly evoked a lifting context. Experiments 3 and 4 showed that weights too heavy (e.g., tons) or too light to be discriminated by lifting, but relevant to other affordances (e.g., grams of a toxin) had effects on time as large or larger than for kilograms. Experiment 5 showed that the effect for grams in a toxicology context did not generalize to the lifting task of Experiment 2. Weight appears to integrate with other magnitudes when it is relevant to meaningful actions, including but not limited to lifting.

  5. Light-weight cyptography for resource constrained environments

    NASA Astrophysics Data System (ADS)

    Baier, Patrick; Szu, Harold

    2006-04-01

    We give a survey of "light-weight" encryption algorithms designed to maximise security within tight resource constraints (limited memory, power consumption, processor speed, chip area, etc.) The target applications of such algorithms are RFIDs, smart cards, mobile phones, etc., which may store, process and transmit sensitive data, but at the same time do not always support conventional strong algorithms. A survey of existing algorithms is given and new proposal is introduced.

  6. Testing and evaluation of a slot and tab construction technique for light-weight wood-fiber-based structural panels under bending

    Treesearch

    Jinghao Li; John F. Hunt; Shaoqin Gong; Zhiyong Cai

    2015-01-01

    This paper presented construction and strain distributions for light-weight wood-fiber-based structural panels with tri-grid core made from phenolic impregnated laminated paper composites under bending. A new fastening configuration of slots in the faces and tabs on the core was applied to the face/core interfaces of the sandwich panel in addition to epoxy resin. Both...

  7. Vertically-aligned carbon nanotubes on aluminum as a light-weight positive electrode for lithium-polysulfide batteries.

    PubMed

    Liatard, S; Benhamouda, K; Fournier, A; Ramos, R; Barchasz, C; Dijon, J

    2015-05-04

    A light-weight, high specific surface current collector made of vertically-aligned carbon nanotubes grown on an aluminum substrate was fabricated and studied as a positive electrode in a semi-liquid lithium/polysulfide battery. This simple system delivered stable capacities over 1000 mA h gS(-1) and 2 mA h cm(-2) with almost no capacity loss over 50 cycles.

  8. Finite element simulation of a novel composite light-weight microporous cladding panel

    NASA Astrophysics Data System (ADS)

    Tian, Lida; Wang, Dongyan

    2018-04-01

    A novel composite light-weight microporous cladding panel with matched connection detailing is developed. Numerical simulation on the experiment is conducted by ABAQUS. The accuracy and rationality of the finite element model is verified by comparison between the simulation and the experiment results. It is also indicated that the novel composite cladding panel is of desirable bearing capacity, stiffness and deformability under out-of-plane load.

  9. Experimental Study on Composite Light-weight Microporous Concrete Cladding Panels

    NASA Astrophysics Data System (ADS)

    Lida, Tian; Dongyan, Wang; Kang, Liu

    2018-03-01

    A new type of composite light-weight microporous concrete cladding panel was developed, with the compound function of retaining and heat preservation. Two specimens of the new cladding panel and connection detailing were made for out-of-plane bending experiment. The results indicate that the new cladding panel and its connection detailing are of sufficient stiffness, bearing capacity and deformability under wind load and out-of-plane seismic action.

  10. Solar central receiver heliostat reflector assembly

    DOEpatents

    Horton, Richard H.; Zdeb, John J.

    1980-01-01

    A heliostat reflector assembly for a solar central receiver system comprises a light-weight, readily assemblable frame which supports a sheet of stretchable reflective material and includes mechanism for selectively applying tension to and positioning the sheet to stretch it to optical flatness. The frame is mounted on and supported by a pipe pedestal assembly that, in turn, is installed in the ground. The frame is controllably driven in a predetermined way by a light-weight drive system so as to be angularly adjustable in both elevation and azimuth to track the sun and efficiently continuously reflect the sun's rays to a focal zone, i.e. central receiver, which forms part of a solar energy utilization system, such as a solar energy fueled electrical power generation system. The frame may include a built-in system for testing for optical flatness of the reflector. The preferable geometric configuration of the reflector is octagonal; however, it may be other shapes, such as hexagonal, pentagonal or square. Several different embodiments of means for tensioning and positioning the reflector to achieve optical flatness are disclosed. The reflector assembly is based on the stretch frame concept which provides an extremely light-weight, simple, low-cost reflector assembly that may be driven for positioning and tracking by a light-weight, inexpensive drive system.

  11. Five-class height-weight model for systematization of seventeen-year-old recruits' anthropometric data.

    PubMed

    Lintsi, Mart; Kaarma, Helje

    2003-12-01

    An anthropometric study of 552 Tartu city and Tartu county recruits aged 17 years was carried out. Height and weight, 33 anthropometric measurements and 12 skinfolds were measured. Body fat percentage was assessed by Omron BF 300 hand-held segmental body fat analyzer. From anthropometric measurements bone mass was derived by the Drink-water et al. (1986) equation, and total skeletal muscle mass by the Lee et al. (2000) equation. The data were systematized into five height-weight SD-classes. There were 3 classes with harmony between height and weight class: 1--small (small height and small weight), 2--medium (medium height and medium weight), 3--large (large height and large weight), 4--weight class dominating (pyknomorphic) and 5--height class dominating (leptomorphic). It was revealed that in classes 1, 2 and 3 the height and weight increase corresponded to the increase in all heights, breadths and depths, circumferences, skinfolds, body fat, muscle and bone mass. In class 4 circumferences, skinfolds, body fat and muscle mass were bigger. In class 5 all heights and the relative bone mass were bigger. The present investigation confirms the hypothesis that the five height-weight class system is applicable to seventeen-year-old recruits.

  12. Fluorescence Lyman-Alpha Stratospheric Hygrometer (FLASH): application on meteorological balloons, long duration balloons and unmanned aerial vehicles.

    NASA Astrophysics Data System (ADS)

    Lykov, Alexey; Khaykin, Sergey; Yushkov, Vladimir; Efremov, Denis; Formanyuk, Ivan; Astakhov, Valeriy

    The FLASH instrument is based on the fluorescent method, which uses H2O molecules photodissociation at a wavelength lambda=121.6 nm (Lalpha - hydrogen emission) followed by the measurement of the fluorescence of excited OH radicals. The source of Lyman-alpha radiation is a hydrogen discharge lamp while the detector of OH fluorescence at 308 -316 nm is a photomultiplier run in photon counting mode. The intensity of the fluorescent light as well as the instrument readings is directly proportional to the water vapor mixing ratio under stratospheric conditions with negligible oxygen absorption. Initially designed for rocket-borne application, FLASH has evolved into a light-weight balloon sonde (FLASH-B) for measurements in the upper troposphere and stratosphere on board meteorological and small plastic balloons. This configuration has been used in over 100 soundings at numerous tropical mid-latitude and polar locations within various international field campaigns. An airborne version of FLASH instrument is successfully utilized onboard stratospheric M55-Geophysica aircraft and tropospheric airborne laboratory YAK42-Roshydromet. The hygrometer was modified for application onboard stratospheric long-duration balloons (FLASH-LDB version). This version was successfully used onboard CNES super-pressure balloon launched from SSC Esrange in March 2007 and flown during 10 days. Special design for polar long duration balloon PoGOLite was created for testing work during polar day in June 2013. Installation and measurement peculiarities as well as observational results are presented. Observations of water vapour using FLASH-B instrument, being of high quality are rather costly as the payload recovery is often complicated and most of the time impossible. Following the goal to find a cost-efficient solution, FLASH was adapted for use onboard Unmanned Aerial Vehicles (UAV). This solution was only possible thanks to compactness and light-weight (0.5 kg) of FLASH instrument. The hygrometer was installed at the nose of a small GPS-controlled glider, which was lifted by a meteorological balloon into the stratosphere and released by a remote command. GPS-based flight control guides and lands the UAV at the launch point thereby allowing multiple usage of its payload. Another sounding platform allowing for multiple usage of the FLASH instrument is a GPS-guided paraglide. The results of measurements acquired in the test flights using different types of balloon-lifted UAVs are presented.

  13. Micron-scale lens array having diffracting structures

    DOEpatents

    Goldberg, Kenneth A

    2013-10-29

    A novel micron-scale lens, a microlens, is engineered to concentrate light efficiently onto an area of interest, such as a small, light-sensitive detector element in an integrated electronic device. Existing microlens designs imitate the form of large-scale lenses and are less effective at small sizes. The microlenses described herein have been designed to accommodate diffraction effects, which dominate the behavior of light at small length scales. Thus a new class of light-concentrating optical elements with much higher relative performance has been created. Furthermore, the new designs are much easier to fabricate than previous designs.

  14. Influence of blue light on the leaf morphoanatomy of in vitro Kalanchoe pinnata (Lamarck) Persoon (Crassulaceae).

    PubMed

    Leal-Costa, Marcos Vinicius; Nascimento, Luana Beatriz dos Santos; Moreira, Nattacha dos Santos; Reinert, Fernanda; Costa, Sônia Soares; Lage, Celso Luiz Salgueiro; Tavares, Eliana Schwartz

    2010-10-01

    Kalanchoe pinnata (Lamarck) Persoon (Crassulaceae) (air plant, miracle leaf) is popularly used to treat gastrointestinal disorders and wounds. Recently, the species was tested to treat cutaneous leishmaniasis with successful results. This medicinal activity was associated with the phenolic fraction of the plant. Blue light induces biosynthesis of phenolic compounds and many changes in anatomical characteristics. We studied the effects of supplementary blue light on the leaf morphology of in vitro K. pinnata. Plants cultured under white light (W plants) only and white light plus blue light (WB plants) show petioles with plain-convex section, amphistomatic leaf blades with simple epidermis, homogeneous mesophyll with densely packed cells, and a single collateral vascular bundle in the midrib. W plants have longer branches, a larger number of nodes per branch, and smaller leaves, whereas WB plant leaves have a thicker upper epidermis and mesophyll. Leaf fresh weight and leaf dry weight were similar in both treatments. Phenolic idioblasts were observed in the plants supplemented with blue light, suggesting that blue light plays an important role in the biosynthesis of phenolic compounds in K. pinnata.

  15. Definition and measurement of rider-intrinsic physical attributes influencing all-terrain vehicle safety.

    PubMed

    Mattei, Tobias A; Bond, Brandon J; Hafner, John W; Morris, Martin J; Travis, Jennifer; Hannah, Greg; Webster, Jim; Lin, Julian J

    2011-11-01

    All-terrain vehicle (ATV) usage has grown tremendously over the years, reaching 9.5 million vehicles in use in 2007. Accompanying this growth has been a concomitant increase in rider morbidity (including traumatic brain and spine injuries) and death, especially in children. The purpose of this study was to define and measure, through field testing, those physical attributes intrinsic to riders, such as height, weight, and wingspan, which may have implications for ATV riders' safety. Three field tests (J-hook, brake, and bump) were developed and performed to allow direct measurement of the lateral, longitudinal, and vertical dynamics in 5 riders of varying heights, weights, and wingspans. Two ATVs, a utility and a sport model, were tested for further comparisons. Data were acquired using a comprehensive data acquisition system attached to the ATVs. Assignment of individual rider/ATV test safety ratings and a rider/ATV Total Safety Rating were made from the results of these field tests. The J-hook test results demonstrated that larger rider wingspans positively influence ATV rider safety and mitigate against lateral instability. From the brake test it was determined that a 10-in (25.4-cm) longitudinal displacement, such as that experienced during a sharp deceleration, for a rider of any height or weight, breached the level of defined safety. As rider weight increased, displacement decreased. The bump test provided evidence that increased rider weight also mitigates against vertical displacement. Individuals with light weights and small wingspans, such as those in the pediatric population, are under considerable risk of injury when operating an ATV due to lateral, longitudinal, and vertical operational instability.

  16. Development of Low Cost Satellite Communications System for Helicopters and General Aviation

    NASA Technical Reports Server (NTRS)

    Farazian, K.; Abbe, B.; Divsalar, D.; Raphaeli, D.; Tulintseff, A.; Wu, T.; Hinedi, S.

    1994-01-01

    In this paper, the development of low-cost satellite communications (SATCOM) system for helicopters and General Aviation (GA) aircrafts is described. System design and standards analysis have been conducted to meet the low-cost, light-weight, small-size and low-power system requirements for helicopters and GA aircraft environments. Other specific issues investigated include coding schemes, spatial diversity, and antenna arraying techniques. Coding schemes employing Channel State Information (CSI) and inverleaving have been studied in order to mitigate severe banking angle fading and the periodic RF signal blockage due to the helicopter rotor blades. In addition, space diversity and antenna arraying techniques have been investigated to further reduce the fading effects and increase the link margin.

  17. Potato leaf explants as a spaceflight plant test system

    NASA Technical Reports Server (NTRS)

    Wheeler, R. M.

    1986-01-01

    The use of explant tissues or organs may circumvent limitations facing whole-plant experimentation during spaceflight. In the case of potato, a crop currently being studied for application to bioregenerative life support systems, excised leaves and their subtended axillary buds can be used to test a variety of stem growth and development phases ranging from tubers through stolons (horizontal stems) to upright leafy shoots. The leaves can be fit well into small-volume test packages and sustained under relatively low irradiance levels using light-weight growing media. Tubers formed on potato leaf cuttings can yield up from 0.5 to 1.0 g fresh mass 10 days after excision and up to 2.0 g or more, 14 days from excision.

  18. Effect of oil liquid viscosity on hysteresis in double-liquid variable-focus lens based on electrowetting

    NASA Astrophysics Data System (ADS)

    Zeng, Zhi; Peng, Runling; He, Mei

    2017-02-01

    The double-liquid variable-focus lens based on the electrowetting has the characteristics of small size, light weight, fast response, and low price and so on. In this paper, double-liquid variable-focus lens's Principle and structure are introduced. The reasons for the existence and improvement of contact angle hysteresis are given according improved Young's equation. At last, 1-Bromododecane with silicone oil are mixed to get oil liquid with different viscosity and proportion liquid as insulating liquid. External voltages are applied to these three liquid lens and focal lengths of the lenses versus applied voltage are investigated. Experiments show that, the decreasing of oil liquid viscosity can reduce focal length hysteresis.

  19. Structure and kinematics of the broad-line regions in active galaxies from IUE variability data

    NASA Technical Reports Server (NTRS)

    Koratkar, Anuradha P.; Gaskell, C. Martin

    1991-01-01

    IUE archival data are used here to investigate the structure nad kinematics of the broad-line regions (BLRs) in nine AGN. It is found that the centroid of the line-continuum cross-correlation functions (CCFs) can be determined with reasonable reliability. The errors in BLR size estimates from CCFs for irregularly sampled light curves are fairly well understood. BLRs are found to have small luminosity-weighted radii, and lines of high ionization tend to be emitted closer to the central source than lines of low ionization, especially for low-luminosity objects. The motion of the gas is gravity-dominated with both pure inflow and pure outflow of high-velocity gas being excluded at a high confidence level for certain geometries.

  20. The Development of a Conical Composite Energy Absorber for Use in the Attenuation of Crash/Impact Loads

    NASA Technical Reports Server (NTRS)

    Littell, Justin D.

    2014-01-01

    A design for a novel light-weight conical shaped energy absorbing (EA) composite subfloor structure is proposed. This composite EA is fabricated using repeated alternating patterns of a conical geometry to form long beam structures which can be implemented as aircraft subfloor keel beams or frame sections. The geometrical features of this conical design, along with the hybrid composite materials used in the manufacturing process give a strength tailored to achieve a constant 25-40 g sustained crush load, small peak crush loads and long stroke limits. This report will discuss the geometrical design and fabrication methods, along with results from static and dynamic crush testing of 12-in. long subcomponents.

  1. Techno-economic analysis of a transient plant-based platform for monoclonal antibody production

    PubMed Central

    Nandi, Somen; Kwong, Aaron T.; Holtz, Barry R.; Erwin, Robert L.; Marcel, Sylvain; McDonald, Karen A.

    2016-01-01

    ABSTRACT Plant-based biomanufacturing of therapeutic proteins is a relatively new platform with a small number of commercial-scale facilities, but offers advantages of linear scalability, reduced upstream complexity, reduced time to market, and potentially lower capital and operating costs. In this study we present a detailed process simulation model for a large-scale new “greenfield” biomanufacturing facility that uses transient agroinfiltration of Nicotiana benthamiana plants grown hydroponically indoors under light-emitting diode lighting for the production of a monoclonal antibody. The model was used to evaluate the total capital investment, annual operating cost, and cost of goods sold as a function of mAb expression level in the plant (g mAb/kg fresh weight of the plant) and production capacity (kg mAb/year). For the Base Case design scenario (300 kg mAb/year, 1 g mAb/kg fresh weight, and 65% recovery in downstream processing), the model predicts a total capital investment of $122 million dollars and cost of goods sold of $121/g including depreciation. Compared with traditional biomanufacturing platforms that use mammalian cells grown in bioreactors, the model predicts significant reductions in capital investment and >50% reduction in cost of goods compared with published values at similar production scales. The simulation model can be modified or adapted by others to assess the profitability of alternative designs, implement different process assumptions, and help guide process development and optimization. PMID:27559626

  2. Techno-economic analysis of a transient plant-based platform for monoclonal antibody production.

    PubMed

    Nandi, Somen; Kwong, Aaron T; Holtz, Barry R; Erwin, Robert L; Marcel, Sylvain; McDonald, Karen A

    Plant-based biomanufacturing of therapeutic proteins is a relatively new platform with a small number of commercial-scale facilities, but offers advantages of linear scalability, reduced upstream complexity, reduced time to market, and potentially lower capital and operating costs. In this study we present a detailed process simulation model for a large-scale new "greenfield" biomanufacturing facility that uses transient agroinfiltration of Nicotiana benthamiana plants grown hydroponically indoors under light-emitting diode lighting for the production of a monoclonal antibody. The model was used to evaluate the total capital investment, annual operating cost, and cost of goods sold as a function of mAb expression level in the plant (g mAb/kg fresh weight of the plant) and production capacity (kg mAb/year). For the Base Case design scenario (300 kg mAb/year, 1 g mAb/kg fresh weight, and 65% recovery in downstream processing), the model predicts a total capital investment of $122 million dollars and cost of goods sold of $121/g including depreciation. Compared with traditional biomanufacturing platforms that use mammalian cells grown in bioreactors, the model predicts significant reductions in capital investment and >50% reduction in cost of goods compared with published values at similar production scales. The simulation model can be modified or adapted by others to assess the profitability of alternative designs, implement different process assumptions, and help guide process development and optimization.

  3. A design-centered approach in developing Al-Si-based light-weight alloys with enhanced fatigue life and strength

    NASA Astrophysics Data System (ADS)

    Fan, Jinghong; Hao, Su

    2004-01-01

    Material heterogeneities and discontinuities such as porosity, second phase particles, and other defects at meso/micro/nano scales, determine fatigue life, strength, and fracture behavior of aluminum castings. In order to achieve better performance of these alloys, a design-centered computer-aided renovative approach is proposed. Here, the term “design-centered” is used to distinguish the new approach from the traditional trial-and-error design approach by formulating a clear objective, offering a scientific foundation, and developing a computer-aided effective tool for the alloy development. A criterion for tailoring “child” microstructure, obtained by “parent” microstructure through statistical correlation, is proposed for the fatigue design at the initial stage. A dislocations pileup model has been developed. This dislocation model, combined with an optimization analysis, provides an analytical-based solution on a small scale for silicon particles and dendrite cells to enhance both fatigue performance and strength for pore-controlled castings. It can also be used to further tailor microstructures. In addition, a conceptual damage sensitivity map for fatigue life design is proposed. In this map there are critical pore sizes, above which fatigue life is controlled by pores; otherwise it is controlled by other mechanisms such as silicon particles and dendrite cells. In the latter case, the proposed criteria and the dislocation model are the foundations of a guideline in the design-centered approach to maximize both the fatigue life and strength of Al-Si-based light-weight alloy.

  4. Low power consumption mini rotary actuator with SMA wires

    NASA Astrophysics Data System (ADS)

    Manfredi, Luigi; Huan, Yu; Cuschieri, Alfred

    2017-11-01

    Shape memory alloys (SMAs) are smart materials widely used as actuators for their high power to weight ratio despite their well-known low energy efficiency and limited mechanical bandwidth. For robotic applications, SMAs exhibit limitations due to high power consumption and limited stroke, varying from 4% to 7% of the total length. Hysteresis, during the contraction and extension cycle, requires a complex control algorithm. On the positive side, the small size and low weight are eminently suited for the design of mini actuators for robotic platforms. This paper describes the design and construction of a light weight and low power consuming mini rotary actuator with on-board contact-less position and force sensors. The design is specifically intended to reduce (i) energy consumption, (ii) dimensions of the sensory system, and (iii) provide a simple control without any need for SMA characterisation. The torque produced is controlled by on-board force sensors. Experiments were performed to investigate the energy consumption and performance (step and sinusoidal angle profiles with a frequency varying from 0.5 to 10 Hz and maximal amplitude of {15}\\circ ). We describe a transient capacitor effect related to the SMA wires during the sinusoidal profile when the active SMA wire is powered and the antagonist one switched-off, resulting in a transient current time varying from 300 to 400 ms.

  5. 1. Keeper's house, small boathouse, and light tower, view east, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Keeper's house, small boathouse, and light tower, view east, west and south sides of keeper's house, west side of boathouse and tower - Great Duck Island Light Station, At southern tip of Great Duck Island southeast of Bass Harbor & northeast of Frenchboro, Frenchboro, Hancock County, ME

  6. Research on fast algorithm of small UAV navigation in non-linear matrix reductionism method

    NASA Astrophysics Data System (ADS)

    Zhang, Xiao; Fang, Jiancheng; Sheng, Wei; Cao, Juanjuan

    2008-10-01

    The low Reynolds numbers of small UAV will result in unfavorable aerodynamic conditions to support controlled flight. And as operated near ground, the small UAV will be affected seriously by low-frequency interference caused by atmospheric disturbance. Therefore, the GNC system needs high frequency of attitude estimation and control to realize the steady of the UAV. In company with the dimensional of small UAV dwindling away, its GNC system is more and more taken embedded designing technology to reach the purpose of compactness, light weight and low power consumption. At the same time, the operational capability of GNC system also gets limit in a certain extent. Therefore, a kind of high speed navigation algorithm design becomes the imminence demand of GNC system. Aiming at such requirement, a kind of non-linearity matrix reduction approach is adopted in this paper to create a new high speed navigation algorithm which holds the radius of meridian circle and prime vertical circle as constant and linearizes the position matrix calculation formulae of navigation equation. Compared with normal navigation algorithm, this high speed navigation algorithm decreases 17.3% operand. Within small UAV"s mission radius (20km), the accuracy of position error is less than 0.13m. The results of semi-physical experiments and small UAV's auto pilot testing proved that this algorithm can realize high frequency attitude estimation and control. It will avoid low-frequency interference caused by atmospheric disturbance properly.

  7. PLUTO AND CHARON WITH THE HUBBLE SPACE TELESCOPE. I. MONITORING GLOBAL CHANGE AND IMPROVED SURFACE PROPERTIES FROM LIGHT CURVES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buie, Marc W.; Young, Eliot F.; Young, Leslie A.

    We present new light-curve measurements of Pluto and Charon taken with the Advanced Camera for Surveys High-resolution Camera on the Hubble Space Telescope. The observations were collected from 2002 June to 2003 June at 12 distinct sub-Earth longitudes over a range of solar phase angle 0.{sup 0}36-1.{sup 0}74-a larger range than previously measured. The new measurements of Pluto show that the light-curve amplitude has decreased since the mutual event season in the late 1980s. We also show that the average brightness has increased in the F555W (Johnson V equivalent) passband while the brightness has decreased in the F435W (Johnson Bmore » equivalent) passband. These data thus indicate a substantial reddening of the reflected light from Pluto. We find a weighted mean (B - V) = 0.9540 {+-} 0.0010 that is considerably higher than the long-standing value of (B - V) = 0.868 {+-} 0.003 most recently measured in 1992-1993. This change in color cannot be explained by the evolving viewing geometry and provides the strongest evidence to date for temporal changes on the surface of Pluto that are expected to be linked to volatile transport processes. We also report on the discovery of a new rotational modulation of Pluto's hemispherical color that ranges from 0.92 to 0.98 with the least red color at the longitude of maximum light and most red at minimum light. The phase coefficient of Pluto is nearly the same as measured in 1992-1993 with a value of {beta} {sub B} = 0.0392 {+-} 0.0064 and {beta} {sub V} = 0.0355 {+-} 0.0045 mag deg{sup -1} for the F435W and F555W data, respectively. The Pluto phase curve is still very close to linear but a small but significant nonlinearity is seen in the data. In contrast, the light curve of Charon is essentially the same as in 1992/1993, albeit with much less noise. We confirm that Charon's Pluto-facing hemisphere is 8% brighter than the hemisphere facing away from Pluto. The color of Charon is independent of longitude and has a mean weighted value of (B - V) = 0.7315 {+-} 0.0013. The phase curve for Charon is now shown to be strongly nonlinear and wavelength dependent. We present results for both Pluto and Charon that better constrain the single-particle scattering parameters from the Hapke scattering theory.« less

  8. Embodied Information in Cognitive Tasks: Haptic Weight Sensations Affect Task Performance and Processing Style

    PubMed Central

    Kaspar, Kai; Vennekötter, Alina

    2015-01-01

    Research in the field of embodied cognition showed that incidental weight sensations influence peoples’ judgments about a variety of issues and objects. Most studies found that heaviness compared to lightness increases the perception of importance, seriousness, and potency. In two experiments, we broadened this scope by investigating the impact of weight sensations on cognitive performance. In Experiment 1, we found that the performance in an anagram task was reduced when participants held a heavy versus a light clipboard in their hands. Reduced performance was accompanied by an increase in the perceived effort. In Experiment 2, a heavy clipboard elicited a specific response heuristic in a two-alternative forced-choice task. Participants showed a significant right side bias when holding a heavy clipboard in their hands. After the task, participants in the heavy clipboard condition reported to be more frustrated than participants in the light clipboard condition. In both experiments, we did not find evidence for mediated effects that had been proposed by previous literature. Overall, the results indicate that weight effects go beyond judgment formation and highlight new avenues for future research. PMID:26421084

  9. Heavy-light, absent-present: rethinking the 'weight' of imprisonment.

    PubMed

    Crewe, Ben; Liebling, Alison; Hulley, Susie

    2014-09-01

    Since King and McDermott (1995), following Downes (1988), defined the psychological oppressiveness of incarceration in terms of 'weight', little has been written about the 'weight of imprisonment'. None the less, it is generally assumed that prisons that are 'light' are preferable to those that are 'heavy' - in part because of an assumption among many penologists that power, and its application, is dangerous and antagonistic. This article does not dispute that 'heavy' prisons are undesirable. Its argument is that there can also be dangers if prisons are excessively light. Many of these dangers are linked to the under-use of power. The tone and quality of prison life depends on the combined effects of institutional weight with the 'absence' or 'presence' of staff power. Drawing on prisoners' descriptions of their experiences in public and private sector prisons, and their assessments of important aspects of their quality of life, the article outlines what these concepts mean in practice. The authors develop a four-quadrant framework for conceptualizeng penal legitimacy and the experience of penal authority. © London School of Economics and Political Science 2014.

  10. Leaf Morphology, Photosynthetic Performance, Chlorophyll Fluorescence, Stomatal Development of Lettuce (Lactuca sativa L.) Exposed to Different Ratios of Red Light to Blue Light.

    PubMed

    Wang, Jun; Lu, Wei; Tong, Yuxin; Yang, Qichang

    2016-01-01

    Red and blue light are both vital factors for plant growth and development. We examined how different ratios of red light to blue light (R/B) provided by light-emitting diodes affected photosynthetic performance by investigating parameters related to photosynthesis, including leaf morphology, photosynthetic rate, chlorophyll fluorescence, stomatal development, light response curve, and nitrogen content. In this study, lettuce plants (Lactuca sativa L.) were exposed to 200 μmol⋅m(-2)⋅s(-1) irradiance for a 16 h⋅d(-1) photoperiod under the following six treatments: monochromatic red light (R), monochromatic blue light (B) and the mixture of R and B with different R/B ratios of 12, 8, 4, and 1. Leaf photosynthetic capacity (A max) and photosynthetic rate (P n) increased with decreasing R/B ratio until 1, associated with increased stomatal conductance, along with significant increase in stomatal density and slight decrease in stomatal size. P n and A max under B treatment had 7.6 and 11.8% reduction in comparison with those under R/B = 1 treatment, respectively. The effective quantum yield of PSII and the efficiency of excitation captured by open PSII center were also significantly lower under B treatment than those under the other treatments. However, shoot dry weight increased with increasing R/B ratio with the greatest value under R/B = 12 treatment. The increase of shoot dry weight was mainly caused by increasing leaf area and leaf number, but no significant difference was observed between R and R/B = 12 treatments. Based on the above results, we conclude that quantitative B could promote photosynthetic performance or growth by stimulating morphological and physiological responses, yet there was no positive correlation between P n and shoot dry weight accumulation.

  11. Leaf Morphology, Photosynthetic Performance, Chlorophyll Fluorescence, Stomatal Development of Lettuce (Lactuca sativa L.) Exposed to Different Ratios of Red Light to Blue Light

    PubMed Central

    Wang, Jun; Lu, Wei; Tong, Yuxin; Yang, Qichang

    2016-01-01

    Red and blue light are both vital factors for plant growth and development. We examined how different ratios of red light to blue light (R/B) provided by light-emitting diodes affected photosynthetic performance by investigating parameters related to photosynthesis, including leaf morphology, photosynthetic rate, chlorophyll fluorescence, stomatal development, light response curve, and nitrogen content. In this study, lettuce plants (Lactuca sativa L.) were exposed to 200 μmol⋅m−2⋅s−1 irradiance for a 16 h⋅d−1 photoperiod under the following six treatments: monochromatic red light (R), monochromatic blue light (B) and the mixture of R and B with different R/B ratios of 12, 8, 4, and 1. Leaf photosynthetic capacity (Amax) and photosynthetic rate (Pn) increased with decreasing R/B ratio until 1, associated with increased stomatal conductance, along with significant increase in stomatal density and slight decrease in stomatal size. Pn and Amax under B treatment had 7.6 and 11.8% reduction in comparison with those under R/B = 1 treatment, respectively. The effective quantum yield of PSII and the efficiency of excitation captured by open PSII center were also significantly lower under B treatment than those under the other treatments. However, shoot dry weight increased with increasing R/B ratio with the greatest value under R/B = 12 treatment. The increase of shoot dry weight was mainly caused by increasing leaf area and leaf number, but no significant difference was observed between R and R/B = 12 treatments. Based on the above results, we conclude that quantitative B could promote photosynthetic performance or growth by stimulating morphological and physiological responses, yet there was no positive correlation between Pn and shoot dry weight accumulation. PMID:27014285

  12. Sensitive Small Area Photometer

    ERIC Educational Resources Information Center

    Levenson, M. D.

    1970-01-01

    Describes a simple photometer capable of measuring small light intensities over small areas. The inexpensive, easy-to- construct instrument is intended for use in a student laboratory to measure the light intensities in a diffraction experiment from single or multiple slits. Typical experimental results are presented along with the theoretical…

  13. Elliptically Framed Tip-Tilt Mirror Optimized for Stellar Tracking

    DTIC Science & Technology

    2015-01-01

    a rotating frame. We used the same materials as the existing tracker; however, light-weighted both the aluminum frame and Zerodur ® mirror . We...as the existing tracker; however, light-weighted both the aluminum frame and Zerodur mirror . We generated a computer-aided design model, converted it...components include an aluminum yoke and ring, glass Zerodur ®4 mirror , piezoelectric (PZT) actuators and stainless steel flexure pivot bearings5. Fig. 1

  14. Towards a light-weight query engine for accessing health sensor data in a fall prevention system.

    PubMed

    Kreiner, Karl; Gossy, Christian; Drobics, Mario

    2014-01-01

    Connecting various sensors in sensor networks has become popular during the last decade. An important aspect next to storing and creating data is information access by domain experts, such as researchers, caretakers and physicians. In this work we present the design and prototypic implementation of a light-weight query engine using natural language processing for accessing health-related sensor data in a fall prevention system.

  15. Method of Making Lightweight, Single Crystal Mirror

    NASA Technical Reports Server (NTRS)

    Bly, Vincent T. (Inventor)

    2015-01-01

    A method of making a mirror from a single crystal blank may include fine grinding top and bottom surfaces of the blank to be parallel. The blank may then be heat treated to near its melting temperature. An optical surface may be created on an optical side of the blank. A protector may be bonded to the optical surface. With the protector in place, the blank may be light weighted by grinding a non-optical surface of the blank using computer controlled grinding. The light weighting may include creating a structure having a substantially minimum mass necessary to maintain distortion of the mirror within a preset limit. A damaged layer of the non-optical surface caused by light weighting may be removed with an isotropic etch and/or repaired by heat treatment. If an oxide layer is present, the entire blank may then be etched using, for example, hydrofluoric acid. A reflecting coating may be deposited on the optical surface.

  16. Weight gain during the first year of life in relation to maternal smoking and breast feeding in Norway.

    PubMed Central

    Nafstad, P; Jaakkola, J J; Hagen, J A; Pedersen, B S; Qvigstad, E; Botten, G; Kongerud, J

    1997-01-01

    OBJECTIVE: To assess the weight gain during the first year of life in relation to maternal smoking during pregnancy and the duration of breastfeeding. DESIGN: This was a one year cohort study. SETTING: The city of Oslo, Norway. PARTICIPANTS: Altogether 3020 children born in Oslo in 1992-93. Children were divided into three groups as follows: 2208 born to non-smoking mothers, 451 to mothers who were light smokers (< 10 cigarettes per day), and 261 to mothers who were heavy smokers (> or = 10 cigarettes per day). MAIN RESULTS: The mean birth weights were 3616 g, 3526 g, and 3382 g and 1 year body weights were 10,056 g (gain 6440 g per year), 10,141 g (6615 g), and 10,158 g (6776 g) in children of non-smoking and light and heavy smoking mothers respectively. Cox regression analysis showed that children of heavy smokers were 2.0 (95% confidence interval, 1.7, 2.3) times and children of light smokers 1.3 (1.2, 1.5) times more likely to have stopped breast feeding during their first year of life compared with children whose mothers were non-smokers. Linear regression analysis, adjusting for confounders, showed that weight gain was slower in breast fed children than in those who were not breast fed (-38 g (-50, -27) per month of breast feeding). Compared with children of non-smokers, the adjusted weight gain was 147 g (40, 255) per year greater in children of light smokers and 184 g (44, 324) per year in children of heavy smokers. CONCLUSION: Children catch up any losses in birth weight due to maternal smoking, but some of the catch up effect is caused by a shorter duration of breast feeding in children of smoking mothers. PMID:9229054

  17. Influence of weight and type of planting material on fruit quality and its heterogeneity in pineapple [Ananas comosus (L.) Merrill].

    PubMed

    Fassinou Hotegni, V Nicodème; Lommen, Willemien J M; Agbossou, Euloge K; Struik, Paul C

    2014-01-01

    Cultural practices can affect the quality of pineapple fruits and its variation. The objectives of this study were to investigate (a) effects of weight class and type of planting material on fruit quality, heterogeneity in quality and proportion and yield of fruits meeting European export standards, and (b) the improvement in quality, proportion and yield of fruits meeting export standards when flowering was induced at optimum time. Experiments were conducted in Benin with cvs Sugarloaf (a Perola type) and Smooth Cayenne. In cv. Sugarloaf, experimental factors were weight class of planting material (light, mixed, heavy) and time of flowering induction (farmers', optimum) (Experiment 1). In cv. Smooth Cayenne an additional experimental factor was the type of planting material (hapas, ground suckers, a mixture of the two) (Experiment 2). Fruits from heavy planting material had higher infructescence and fruit weights, longer infructescences, shorter crowns, and smaller crown: infructescence length than fruits from light planting material. The type of planting material in Experiment 2 did not significantly affect fruit quality except crown length: fruits from hapas had shorter crowns than those from ground suckers. Crops from heavy planting material had a higher proportion and yield of fruits meeting export standards than those from other weight classes in Experiment 1 only; also the type of planting material in Experiment 2 did not affect these variates. Heterogeneity in fruit quality was usually not reduced by selecting only light or heavy planting material instead of mixing weights; incidentally the coefficient of variation was significantly reduced in fruits from heavy slips only. Heterogeneity was also not reduced by not mixing hapas and ground suckers. Flowering induction at optimum time increased the proportion and yield of fruits meeting export standards in fruits from light and mixed slip weights and in those from the mixture of heavy hapas plus ground suckers.

  18. Influence of weight and type of planting material on fruit quality and its heterogeneity in pineapple [Ananas comosus (L.) Merrill

    PubMed Central

    Fassinou Hotegni, V. Nicodème; Lommen, Willemien J. M.; Agbossou, Euloge K.; Struik, Paul C.

    2015-01-01

    Cultural practices can affect the quality of pineapple fruits and its variation. The objectives of this study were to investigate (a) effects of weight class and type of planting material on fruit quality, heterogeneity in quality and proportion and yield of fruits meeting European export standards, and (b) the improvement in quality, proportion and yield of fruits meeting export standards when flowering was induced at optimum time. Experiments were conducted in Benin with cvs Sugarloaf (a Perola type) and Smooth Cayenne. In cv. Sugarloaf, experimental factors were weight class of planting material (light, mixed, heavy) and time of flowering induction (farmers', optimum) (Experiment 1). In cv. Smooth Cayenne an additional experimental factor was the type of planting material (hapas, ground suckers, a mixture of the two) (Experiment 2). Fruits from heavy planting material had higher infructescence and fruit weights, longer infructescences, shorter crowns, and smaller crown: infructescence length than fruits from light planting material. The type of planting material in Experiment 2 did not significantly affect fruit quality except crown length: fruits from hapas had shorter crowns than those from ground suckers. Crops from heavy planting material had a higher proportion and yield of fruits meeting export standards than those from other weight classes in Experiment 1 only; also the type of planting material in Experiment 2 did not affect these variates. Heterogeneity in fruit quality was usually not reduced by selecting only light or heavy planting material instead of mixing weights; incidentally the coefficient of variation was significantly reduced in fruits from heavy slips only. Heterogeneity was also not reduced by not mixing hapas and ground suckers. Flowering induction at optimum time increased the proportion and yield of fruits meeting export standards in fruits from light and mixed slip weights and in those from the mixture of heavy hapas plus ground suckers. PMID:25653659

  19. [Effects of forest gap size and light intensity on herbaceous plants in Pinus koraiensis-dominated broadleaved mixed forest].

    PubMed

    Duan, Wen-Biao; Wang, Li-Xia; Chen, Li-Xin; Du, Shan; Wei, Quan-Shuai; Zhao, Jian-Hui

    2013-03-01

    1 m x 1 m fixed quadrats were parallelly arranged with a space of 2 m in each of six forest gaps in Pinus koraiensis-dominated broadleaved mixed forest, taking the gap center as the starting point and along east-west and south-north directions. In each quadrat, the coverage and abundance of herbaceous plants at different height levels were investigated by estimation method in June and September 2011, and the matrix characteristics within the quadrats were recorded. Canopy analyzer was used to take fish-eye photos in the selected overcast days in each month from June to September, 2011, and the relative light intensity was calculated by using Gap Light Analyzer 2.0 software. The differences in the relative light intensity and herbaceous plants coverage and richness between different gaps as well as the correlations between the coverage of each species and the direct light, diffuse light, and matrix were analyzed. The results showed that in opening areas and under canopy, the relative light intensity in large gaps was higher than that in small gaps, and the variation ranges of diffuse light and direct light from gap center to gap edge were bigger in large gaps than in small gaps. The direct light reaching at the ground both in large gaps and in small gaps was higher in the north than in the south direction. In the Z1, Z2, Z3, and Z4 zones, both the coverage and the richness of herbaceous plants were larger in large gaps than in small gaps, and the differences of species richness between large and small gaps reached significant level. The coverage of the majority of the herbaceous plants had significant correlations with diffuse light and matrix, and only the coverage of a few herbaceous plants was correlated with direct light.

  20. Fault-Tolerant Heat Exchanger

    NASA Technical Reports Server (NTRS)

    Izenson, Michael G.; Crowley, Christopher J.

    2005-01-01

    A compact, lightweight heat exchanger has been designed to be fault-tolerant in the sense that a single-point leak would not cause mixing of heat-transfer fluids. This particular heat exchanger is intended to be part of the temperature-regulation system for habitable modules of the International Space Station and to function with water and ammonia as the heat-transfer fluids. The basic fault-tolerant design is adaptable to other heat-transfer fluids and heat exchangers for applications in which mixing of heat-transfer fluids would pose toxic, explosive, or other hazards: Examples could include fuel/air heat exchangers for thermal management on aircraft, process heat exchangers in the cryogenic industry, and heat exchangers used in chemical processing. The reason this heat exchanger can tolerate a single-point leak is that the heat-transfer fluids are everywhere separated by a vented volume and at least two seals. The combination of fault tolerance, compactness, and light weight is implemented in a unique heat-exchanger core configuration: Each fluid passage is entirely surrounded by a vented region bridged by solid structures through which heat is conducted between the fluids. Precise, proprietary fabrication techniques make it possible to manufacture the vented regions and heat-conducting structures with very small dimensions to obtain a very large coefficient of heat transfer between the two fluids. A large heat-transfer coefficient favors compact design by making it possible to use a relatively small core for a given heat-transfer rate. Calculations and experiments have shown that in most respects, the fault-tolerant heat exchanger can be expected to equal or exceed the performance of the non-fault-tolerant heat exchanger that it is intended to supplant (see table). The only significant disadvantages are a slight weight penalty and a small decrease in the mass-specific heat transfer.

  1. The effect of intermittent lighting on metabolizable energy intake and heat production of male broilers.

    PubMed

    Ohtani, S; Leeson, S

    2000-02-01

    Experiments were conducted to compare the effects of an intermittent lighting (IL) schedule with repeated cycles of 1 h light and 2 h darkness with a continuous lighting (CL) schedule on the performance, ME intake, and heat production of male broiler chickens. Body weight gain and feed intake were temporarily reduced after the changing from CL to IL; however, they were significantly higher in IL vs CL chickens during the subsequent period of 3 to 6 wk of age. The IL chickens exhibited a higher ME intake at 6 and 8 wk of age than did CL chickens. Total heat production in IL chickens was higher than for CL chickens, although heat production during the dark period was less than that during the light period for IL chickens. The higher feed intake observed in IL chickens appears to explain the superior body weight gain in IL broilers in simple terms.

  2. Solution Properties of Amphoteric Random Copolymers Bearing Pendant Sulfonate and Quaternary Ammonium Groups with Controlled Structures.

    PubMed

    Nakahata, Rina; Yusa, Shin-Ichi

    2018-01-05

    Amphoteric random copolymers P(AMPS/APTAC50) x , where x = 41, 89, and 117, composed of sodium 2-acrylamido-2-methylpropanesulfonate (AMPS) and 3-acrylamidopropyltrimethylammonium chloride (APTAC) were prepared via reversible addition-fragmentation chain transfer radical polymerization. P(AMPS/APTAC50) x can dissolve in pure water to form small interpolymer aggregates. In aqueous solutions of NaCl, P(AMPS/APTAC50) x can dissolve in the unimer state. Amphoteric random copolymer P(AMPS/APTAC50) c with high molecular weight was prepared via conventional free-radical polymerization. Although P(AMPS/APTAC50) c cannot dissolve in pure water, it can dissolve in aqueous solutions of NaCl. In amphoteric random copolymers with high molecular weight, the possibility of continuous sequences of monomers with the same charge may increase, which may cause strong interactions between polymer chains. When fetal bovine serum (FBS) and polyelectrolytes were mixed in phosphate-buffered saline, the hydrodynamic radius and light-scattering intensity increased. There was no interaction between P(AMPS/APTAC50) x and FBS because corresponding increases could not be observed.

  3. Failure mode prediction for composite structural insulated panels with MgO board facings

    NASA Astrophysics Data System (ADS)

    Smakosz, Łukasz; Kreja, Ireneusz

    2018-01-01

    Sandwich panels are readily used in civil engineering due to their high strength to weight ratio and the ease and speed of assembly. The idea of a sandwich section is to combine thin and durable facings with a light-weight core and the choice of materials used allows obtaining the desired behaviour. Panels in consideration consist of MgO (magnesium oxide) board facings and expanded polystyrene core and are characterized by immunity to biological corrosion, a high thermal insulation and a relatively low impact on environment. Customizing the range of panels to meet market needs requires frequent size changes, leading to different failure modes, which are identified in a series of costly full-scale laboratory tests. A nonlinear numerical model was created with a use of a commercial ABAQUS code and a user-defined procedure, which is able to reproduce observed failure mechanisms; its parameters were established on the basis of small-scale tests and numerical experiments. The model was validated by a comparison with the results of the full-scale bending and compression tests. The results obtained were in satisfactory agreement with the test data.

  4. Hybrid of two-photon microscopy and optical multimodality imaging for multi-scale imaging of small animals

    NASA Astrophysics Data System (ADS)

    Li, Tianmeng; Hui, Hui; Ma, He; Yang, Xin; Tian, Jie

    2018-02-01

    Non-invasive imaging technologies, such as magnetic resonance imaging (MRI) and optical multimodality imaging methods, are commonly used for diagnosing and supervising the development of inflammatory bowel disease (IBD). These in vivo imaging methods can provide morphology changes information of IBD in macro-scale. However, it is difficult to investigate the intestinal wall in molecular and cellular level. State-of-art light-sheet and two-photon microscopy have the ability to acquire the changes for IBD in micro-scale. The aim of this work is to evaluate the size of the enterocoel and the thickness of colon wall using both MRI for in vivo imaging, and light-sheet and two-photon microscope for in vitro imaging. C57BL/6 mice were received 3.5% Dextran sodium sulfate (DSS) in the drinking water for 5 days to build IBD model. Mice were imaged with MRI on days 0, 6 to observe colitis progression. After MRI imaging, the mice were sacrificed to take colons for tissue clearing. Then, light-sheet and two-photon microscopies are used for in vitro imaging of the cleared samples. The experimental group showed symptoms of bloody stools, sluggishness and weight loss. It showed that the colon wall was thicker while the enterocoel was narrower compare to control group. The more details are observed using light-sheet and two-photon microscope. It is demonstrated that hybrid of MRI in macro-scale and light-sheet and two-photon microscopy in micro-scale imaging is feasible for colon inflammation diagnosing and supervising.

  5. Rotorcraft Weight Trends in Light of Structural Material Characteristics

    DTIC Science & Technology

    1987-04-26

    torsion W weight for tota We weight empty v tail rotor 0 mass ratio got ultimate to specific weight I wVater S specific gravity * twist, torsion...imagined meters. An alternate way of expressing the weight effectiveness of materials may be based on the specific gravity of the material. In this...specific weight of distilled water at 40C, and 6. is the specific gravity of the considered structural material. Since, obviously, 7,, - const, it may

  6. A new method to manipulate broiler chicken growth and metabolism: Response to mixed LED light system

    PubMed Central

    Yang, Yefeng; Yu, Yonghua; Pan, Jinming; Ying, Yibin; Zhou, Hong

    2016-01-01

    Present study introduced a new method to manipulate broiler chicken growth and metabolism by mixing the growth-advantage LED. We found that the green/blue LED mixed light system (G-B and G × B) have the similar stimulatory effect on chick body weight with single green light and single blue light (G and B), compared with normal artificial light (P = 0.028). Moreover, the percentage of carcass was significantly greater in the mixed light (G × B) when compared with the single light (P = 0.003). Synchronized with body weight, the mixed light (G-B and G × B) had a significant improved influence on the feed conversion of birds compared with normal light (P = 0.002). A significant improvement in feed conversion were found in mixed light (G × B) compared with single LED light (P = 0.037). G group resulted in a greater high-density lipoprotein cholesterol level than B group (P = 0.002), whereas B group resulted in a greater low-density lipoprotein cholesterol level than G group (P = 0.017). The mixed light significantly increased the birds’ glucose level in comparison with the single light (P = 0.003). This study might establish an effective strategy for maximizing growth of chickens by mixed LED technology. PMID:27170597

  7. A new method to manipulate broiler chicken growth and metabolism: Response to mixed LED light system.

    PubMed

    Yang, Yefeng; Yu, Yonghua; Pan, Jinming; Ying, Yibin; Zhou, Hong

    2016-05-12

    Present study introduced a new method to manipulate broiler chicken growth and metabolism by mixing the growth-advantage LED. We found that the green/blue LED mixed light system (G-B and G × B) have the similar stimulatory effect on chick body weight with single green light and single blue light (G and B), compared with normal artificial light (P = 0.028). Moreover, the percentage of carcass was significantly greater in the mixed light (G × B) when compared with the single light (P = 0.003). Synchronized with body weight, the mixed light (G-B and G × B) had a significant improved influence on the feed conversion of birds compared with normal light (P = 0.002). A significant improvement in feed conversion were found in mixed light (G × B) compared with single LED light (P = 0.037). G group resulted in a greater high-density lipoprotein cholesterol level than B group (P = 0.002), whereas B group resulted in a greater low-density lipoprotein cholesterol level than G group (P = 0.017). The mixed light significantly increased the birds' glucose level in comparison with the single light (P = 0.003). This study might establish an effective strategy for maximizing growth of chickens by mixed LED technology.

  8. A new method to manipulate broiler chicken growth and metabolism: Response to mixed LED light system

    NASA Astrophysics Data System (ADS)

    Yang, Yefeng; Yu, Yonghua; Pan, Jinming; Ying, Yibin; Zhou, Hong

    2016-05-01

    Present study introduced a new method to manipulate broiler chicken growth and metabolism by mixing the growth-advantage LED. We found that the green/blue LED mixed light system (G-B and G × B) have the similar stimulatory effect on chick body weight with single green light and single blue light (G and B), compared with normal artificial light (P = 0.028). Moreover, the percentage of carcass was significantly greater in the mixed light (G × B) when compared with the single light (P = 0.003). Synchronized with body weight, the mixed light (G-B and G × B) had a significant improved influence on the feed conversion of birds compared with normal light (P = 0.002). A significant improvement in feed conversion were found in mixed light (G × B) compared with single LED light (P = 0.037). G group resulted in a greater high-density lipoprotein cholesterol level than B group (P = 0.002), whereas B group resulted in a greater low-density lipoprotein cholesterol level than G group (P = 0.017). The mixed light significantly increased the birds’ glucose level in comparison with the single light (P = 0.003). This study might establish an effective strategy for maximizing growth of chickens by mixed LED technology.

  9. Human-Friendly Light-Emitting Diode Source Stimulates Broiler Growth.

    PubMed

    Pan, Jinming; Yang, Yefeng; Yang, Bo; Dai, Wenhua; Yu, Yonghua

    2015-01-01

    Previous study and our laboratory have reported that short-wavelength (blue and green) light and combination stimulate broiler growth. However, short-wavelength stimuli could have negative effects on poultry husbandry workers. The present study was conducted to evaluate the effects of human-friendly yellow LED light, which is acceptable to humans and close to green light, on broiler growth. We also aimed to investigate the potential quantitative relationship between the wavelengths of light used for artificial illumination and growth parameters in broilers. After hatching, 360 female chicks ("Meihuang" were evenly divided into six lighting treatment groups: white LED strips (400-700 nm, WL); red LED strips (620 nm, RL); yellow LED strips (580 nm, YL); green LED strips (514 nm, GL); blue LED strips (455 nm, BL); and fluorescent strips (400-700 nm, FL). From 30 to 72 days of age, broilers reared under YL and GL were heavier than broilers treated with FL (P < 0.05). Broilers reared under YL obtained the similar growth parameters with the broilers reared under GL and BL (P > 0.05). Moreover, YL significantly improved feeding efficiency when compared with GL and BL at 45 and 60 days of age (P < 0.05). In addition, we found an age-dependent effect of light spectra on broiler growth and a quantitative relationship between LED light spectra (455 to 620 nm) and the live body weights of broilers. The wavelength of light (455 to 620 nm) was found to be negatively related (R2 = 0.876) to live body weight at an early stage of development, whereas the wavelength of light (455 to 620 nm) was found to be positively correlated with live body weight (R2 = 0.925) in older chickens. Our results demonstrated that human-friendly yellow LED light (YL), which is friendly to the human, can be applied to the broilers production.

  10. Human-Friendly Light-Emitting Diode Source Stimulates Broiler Growth

    PubMed Central

    Yang, Bo; Dai, Wenhua; Yu, Yonghua

    2015-01-01

    Previous study and our laboratory have reported that short-wavelength (blue and green) light and combination stimulate broiler growth. However, short-wavelength stimuli could have negative effects on poultry husbandry workers. The present study was conducted to evaluate the effects of human-friendly yellow LED light, which is acceptable to humans and close to green light, on broiler growth. We also aimed to investigate the potential quantitative relationship between the wavelengths of light used for artificial illumination and growth parameters in broilers. After hatching, 360 female chicks (“Meihuang” were evenly divided into six lighting treatment groups: white LED strips (400–700 nm, WL); red LED strips (620 nm, RL); yellow LED strips (580 nm, YL); green LED strips (514 nm, GL); blue LED strips (455 nm, BL); and fluorescent strips (400–700 nm, FL). From 30 to 72 days of age, broilers reared under YL and GL were heavier than broilers treated with FL (P < 0.05). Broilers reared under YL obtained the similar growth parameters with the broilers reared under GL and BL (P > 0.05). Moreover, YL significantly improved feeding efficiency when compared with GL and BL at 45 and 60 days of age (P < 0.05). In addition, we found an age-dependent effect of light spectra on broiler growth and a quantitative relationship between LED light spectra (455 to 620 nm) and the live body weights of broilers. The wavelength of light (455 to 620 nm) was found to be negatively related (R 2 = 0.876) to live body weight at an early stage of development, whereas the wavelength of light (455 to 620 nm) was found to be positively correlated with live body weight (R 2 = 0.925) in older chickens. Our results demonstrated that human-friendly yellow LED light (YL), which is friendly to the human, can be applied to the broilers production. PMID:26270988

  11. Exercise attenuates the metabolic effects of dim light at night.

    PubMed

    Fonken, Laura K; Meléndez-Fernández, O Hecmarie; Weil, Zachary M; Nelson, Randy J

    2014-01-30

    Most organisms display circadian rhythms that coordinate complex physiological and behavioral processes to optimize energy acquisition, storage, and expenditure. Disruptions to the circadian system with environmental manipulations such as nighttime light exposure alter metabolic energy homeostasis. Exercise is known to strengthen circadian rhythms and to prevent weight gain. Therefore, we hypothesized providing mice a running wheel for voluntary exercise would buffer against the effects of light at night (LAN) on weight gain. Mice were maintained in either dark (LD) or dim (dLAN) nights and provided either a running wheel or a locked wheel. Mice exposed to dim, rather than dark, nights increased weight gain. Access to a functional running wheel prevented body mass gain in mice exposed to dLAN. Voluntary exercise appeared to limit weight gain independently of rescuing changes to the circadian system caused by dLAN; increases in daytime food intake induced by dLAN were not diminished by increased voluntary exercise. Furthermore, although all of the LD mice displayed a 24h rhythm in wheel running, nearly half (4 out of 9) of the dLAN mice did not display a dominant 24h rhythm in wheel running. These results indicate that voluntary exercise can prevent weight gain induced by dLAN without rescuing circadian rhythm disruptions. © 2013.

  12. Structural characterization and observation of variable range hopping conduction mechanism at high temperature in CdSe quantum dot solids

    NASA Astrophysics Data System (ADS)

    Sinha, Subhojyoti; Kumar Chatterjee, Sanat; Ghosh, Jiten; Kumar Meikap, Ajit

    2013-03-01

    We have used Rietveld refinement technique to extract the microstructural parameters of thioglycolic acid capped CdSe quantum dots. The quantum dot formation and its efficient capping are further confirmed by HR-TEM, UV-visible and FT-IR spectroscopy. Comparative study of the variation of dc conductivity with temperature (298 K ≤ T ≤ 460 K) is given considering Arrhenius formalism, small polaron hopping and Schnakenberg model. We observe that only Schnakenberg model provides good fit to the non-linear region of the variation of dc conductivity with temperature. Experimental variation of ac conductivity and dielectric parameters with temperature (298 K ≤ T ≤ 460 K) and frequency (80 Hz ≤ f ≤ 2 MHz) are discussed in the light of hopping theory and quantum confinement effect. We have elucidated the observed non-linearity in the I-V curves (measured within ±50 V), at dark and at ambient light, in view of tunneling mechanism. Tunnel exponents and non-linearity weight factors have also been evaluated in this regard.

  13. A framework for small infrared target real-time visual enhancement

    NASA Astrophysics Data System (ADS)

    Sun, Xiaoliang; Long, Gucan; Shang, Yang; Liu, Xiaolin

    2015-03-01

    This paper proposes a framework for small infrared target real-time visual enhancement. The framework is consisted of three parts: energy accumulation for small infrared target enhancement, noise suppression and weighted fusion. Dynamic programming based track-before-detection algorithm is adopted in the energy accumulation to detect the target accurately and enhance the target's intensity notably. In the noise suppression, the target region is weighted by a Gaussian mask according to the target's Gaussian shape. In order to fuse the processed target region and unprocessed background smoothly, the intensity in the target region is treated as weight in the fusion. Experiments on real small infrared target images indicate that the framework proposed in this paper can enhances the small infrared target markedly and improves the image's visual quality notably. The proposed framework outperforms tradition algorithms in enhancing the small infrared target, especially for image in which the target is hardly visible.

  14. Schizophrenia and weight management: a systematic review of interventions to control weight.

    PubMed

    Faulkner, G; Soundy, A A; Lloyd, K

    2003-11-01

    Weight gain is a frequent side effect of antipsychotic medication which has serious implications for a patient's health and well being. This study systematically reviews the literature on the effectiveness of interventions designed to control weight gain in schizophrenia. A systematic search strategy was conducted of major databases in addition to citation searches. Study quality was rated. Sixteen studies met the inclusion criteria. Five of eight pharmacological intervention studies reported small reductions in weight (<5% baseline body weight). All behavioural (including diet and/or exercise) interventions reported small reductions in, or maintenance of, weight. Weight loss may be difficult but it is not impossible. Given the inconsistent results, the widespread use of pharmacological interventions cannot be recommended. Both dietary and exercise counselling set within a behavioural modification programme is necessary for sustained weight control.

  15. Specific light uptake rates can enhance astaxanthin productivity in Haematococcus lacustris.

    PubMed

    Lee, Ho-Sang; Kim, Z-Hun; Park, Hanwool; Lee, Choul-Gyun

    2016-05-01

    Lumostatic operation was applied for efficient astaxanthin production in autotrophic Haematococcus lacustris cultures using 0.4-L bubble column photobioreactors. The lumostatic operation in this study was performed with three different specific light uptake rates (q(e)) based on cell concentration, cell projection area, and fresh weight as one-, two- and three-dimensional characteristics values, respectively. The q(e) value from the cell concentration (q(e1D)) obtained was 13.5 × 10⁻⁸ μE cell⁻¹ s⁻¹, and the maximum astaxanthin concentration was increased to 150 % compared to that of a control with constant light intensity. The other optimum q e values by cell projection area (q(e2D)) and fresh weight (q( e3D)) were determined to be 195 μE m⁻² s⁻¹ and 10.5 μE g⁻¹ s⁻¹ for astaxanthin production, respectively. The maximum astaxanthin production from the lumostatic cultures using the parameters controlled by cell projection area (2D) and fresh weight (3D) also increased by 36 and 22% over that of the controls, respectively. When comparing the optimal q e values among the three different types, the lumostatic cultures using q(e) based on fresh weight showed the highest astaxanthin productivity (22.8 mg L⁻¹ day⁻¹), which was a higher level than previously reported. The lumostatic operations reported here demonstrated that more efficient and effective astaxanthin production was obtained by H. lacustris than providing a constant light intensity, regardless of which parameter is used to calculate the specific light uptake rate.

  16. Proposal of AAA-battery-size one-shot ATR Fourier spectroscopic imager for on-site analysis: Simultaneous measurement of multi-components with high accuracy

    NASA Astrophysics Data System (ADS)

    Hosono, Satsuki; Qi, Wei; Sato, Shun; Suzuki, Yo; Fujiwara, Masaru; Hiramatsu, Hiroyuki; Suzuki, Satoru; Abeygunawardhana, P. K. W.; Wada, Kenji; Nishiyama, Akira; Ishimaru, Ichiro

    2015-03-01

    For simultaneous measurement of multi-components on-site like factories, the ultra-compact (diameter: 9[mm], length: 45[mm], weight: 200[g]) one-shot ATR (Attenuated Total Reflection) Fourier spectroscopic imager was proposed. Because the proposed one-shot Fourier spectroscopic imaging is based on spatial-phase-shift interferometer, interferograms could be obtained with simple optical configurations. We introduced the transmission-type relativeinclined phase-shifter, that was constructed with a cuboid prism and a wedge prism, onto the optical Fourier transform plane of infinity corrected optical systems. And also, small light-sources and cameras in the mid-infrared light region, whose size are several millimeter on a side, are essential components for the ultra-compact spectroscopic configuration. We selected the Graphite light source (light source area: 1.7×1.7[mm], maker: Hawkeye technologies) whose radiation factor was high. Fortunately, in these days we could apply the cost-effective 2-dimensional light receiving device for smartphone (e.g. product name: LEPTON, maker: FLIR, price: around 400USD). In the case of alcoholic drinks factory, conventionally workers measure glucose and ethanol concentrations by bringing liquid solution back to laboratories every day. The high portable spectroscopy will make it possible to measure multi-components simultaneously on manufacturing scene. But we found experimentally that absorption spectrum of glucose and water and ethanol were overlapped each other in near infrared light region. But for mid-infrared light region, we could distinguish specific absorption peaks of glucose (@10.5[μm]) and ethanol (@11.5[μm]) independently from water absorption. We obtained standard curve between absorption (@9.6[μm]) and ethanol concentration with high correlation coefficient 0.98 successfully by ATR imaging-type 2-dimensional Fourier spectroscopy (wavelength resolution: 0.057[μm]) with the graphite light source (maker: Hawkeye technologies, type: IR-75).

  17. Tailored Buckling Microlattices as Reusable Light-Weight Shock Absorbers.

    PubMed

    Frenzel, Tobias; Findeisen, Claudio; Kadic, Muamer; Gumbsch, Peter; Wegener, Martin

    2016-07-01

    Structures and materials absorbing mechanical (shock) energy commonly exploit either viscoelasticity or destructive modifications. Based on a class of uniaxial light-weight geometrically nonlinear mechanical microlattices and using buckling of inner elements, either a sequence of snap-ins followed by irreversible hysteretic - yet repeatable - self-recovery or multistability is achieved, enabling programmable behavior. Proof-of-principle experiments on three-dimensional polymer microstructures are presented. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. GLIDE: a grid-based light-weight infrastructure for data-intensive environments

    NASA Technical Reports Server (NTRS)

    Mattmann, Chris A.; Malek, Sam; Beckman, Nels; Mikic-Rakic, Marija; Medvidovic, Nenad; Chrichton, Daniel J.

    2005-01-01

    The promise of the grid is that it will enable public access and sharing of immense amounts of computational and data resources among dynamic coalitions of individuals and institutions. However, the current grid solutions make several limiting assumptions that curtail their widespread adoption. To address these limitations, we present GLIDE, a prototype light-weight, data-intensive middleware infrastructure that enables access to the robust data and computational power of the grid on DREAM platforms.

  19. Global carbon benefits of material substitution in passenger cars until 2050 and the impact on the steel and aluminum industries.

    PubMed

    Modaresi, Roja; Pauliuk, Stefan; Løvik, Amund N; Müller, Daniel B

    2014-09-16

    Light-weighting of passenger cars using high-strength steel or aluminum is a common emissions mitigation strategy. We provide a first estimate of the global impact of light-weighting by material substitution on GHG emissions from passenger cars and the steel and aluminum industries until 2050. We develop a dynamic stock model of the global car fleet and combine it with a dynamic MFA of the associated steel, aluminum, and energy supply industries. We propose four scenarios for substitution of conventional steel with high-strength steel and aluminum at different rates over the period 2010-2050. We show that light-weighting of passenger cars can become a "gigaton solution": Between 2010 and 2050, persistent light-weighting of passenger cars can, under optimal conditions, lead to cumulative GHG emissions savings of 9-18 gigatons CO2-eq compared to development business-as-usual. Annual savings can be up to 1 gigaton per year. After 2030, enhanced material recycling can lead to further reductions: closed-loop metal recycling in the automotive sector may reduce cumulative emissions by another 4-6 gigatons CO2-eq. The effectiveness of emissions mitigation by material substitution significantly depends on how the recycling system evolves. At present, policies focusing on tailpipe emissions and life cycle assessments of individual cars do not consider this important effect.

  20. Polymer and small molecule based hybrid light source

    DOEpatents

    Choong, Vi-En; Choulis, Stelios; Krummacher, Benjamin Claus; Mathai, Mathew; So, Franky

    2010-03-16

    An organic electroluminescent device, includes: a substrate; a hole-injecting electrode (anode) coated over the substrate; a hole injection layer coated over the anode; a hole transporting layer coated over the hole injection layer; a polymer based light emitting layer, coated over the hole transporting layer; a small molecule based light emitting layer, thermally evaporated over the polymer based light emitting layer; and an electron-injecting electrode (cathode) deposited over the electroluminescent polymer layer.

  1. Effective phase function of light scattered at small angles by polydisperse particulate media

    NASA Astrophysics Data System (ADS)

    Turcu, I.

    2008-06-01

    Particles with typical dimensions higher than the light wavelength and relative refraction indexes close to one, scatter light mainly in the forward direction where the scattered light intensity has a narrow peak. For particulate media accomplishing these requirements the light scattered at small angles in a far-field detecting set-up can be described analytically by an effective phase function (EPF) even in the multiple scattering regime. The EPF model which was built for monodispersed systems has been extended to polydispersed media. The main ingredients consist in the replacement of the single particle phase function and of the optical thickness with their corresponding averaged values. Using a Gamma particle size distribution (PSD) as a testing model, the effect of polydispersity was systematically investigated. The increase of the average radius or/and of the PSD standard deviation leads to the decrease of the angular spreading of the small angle scattered light.

  2. Impact of Small Body Weight on Tenofovir-Associated Renal Dysfunction in HIV-Infected Patients: A Retrospective Cohort Study of Japanese Patients

    PubMed Central

    Nishijima, Takeshi; Komatsu, Hirokazu; Gatanaga, Hiroyuki; Aoki, Takahiro; Watanabe, Koji; Kinai, Ei; Honda, Haruhito; Tanuma, Junko; Yazaki, Hirohisa; Tsukada, Kunihisa; Honda, Miwako; Teruya, Katsuji; Kikuchi, Yoshimi; Oka, Shinichi

    2011-01-01

    Background Treatment with tenofovir is sometimes associated with renal dysfunction. Limited information is available on this side effect in patients with small body weight, although the use of tenofovir will spread rapidly in Asia and Africa, where patients are likely to be of smaller body weight. Methods In a single-center cohort, Japanese patients with HIV infection who started tenofovir-containing antiretroviral therapy were retrospectively analyzed. The incidence of tenofovir-associated renal dysfunction, defined as more than 25% decrement of estimated glomerular filtration rate (eGFR) from the baseline, was determined. The effects of small body weight and body mass index (BMI) on tenofovir-associated renal dysfunction, respectively, were estimated in univariate and multivariate Cox hazards models as the primary exposure. Other possible risk factors were evaluated by univariate analysis and those found significant were entered into the multivariate analysis. Results The median weight of 495 patients was 63 kg. Tenofovir-related renal dysfunction occurred in 97 (19.6%) patients (incidence: 10.5 per 100 person-years). Univariate analysis showed that the incidence of tenofovir-related renal dysfunction was significantly associated with smaller body weight and BMI, respectively (per 5 kg decrement, HR = 1.23; 95% CI, 1.10–1.37; p<0.001)(per 1 kg/m2 decrement, HR = 1.14; 95% CI, 1.05–1.23; p = 0.001). Old age, high baseline eGFR, low serum creatinine, low CD4 count, high HIV viral load, concurrent nephrotoxic drugs, hepatitis C infection, and current smoking were also associated with tenofovir-related renal dysfunction. Multivariate analysis identified small body weight as a significant risk (adjusted HR = 1.13; 95% CI, 1.01–1.27; p = 0.039), while small BMI had marginal significance (adjusted HR = 1.07; 95% CI 1.00–1.16; p = 0.058). Conclusion The incidence of tenofovir-associated renal dysfunction in Japanese patients was high. Small body weight was identified as an independent risk factor for tenofovir-associated renal dysfunction. Close monitoring of renal function is advocated for patients with small body weight treated with tenofovir. PMID:21799928

  3. Interactive effects of and light on growth rates and RUBISCO content of small and large centric diatoms

    NASA Astrophysics Data System (ADS)

    Li, G.; Campbell, D. A.

    2015-10-01

    Among marine phytoplankton groups, diatoms span the widest range of cell size, with resulting effects upon their nitrogen uptake, photosynthesis and growth responses to light. We grew two strains of marine centric diatoms, the small Thalassiosira pseudonana and the larger T. punctigera in high and low nitrogen media, across a range of growth light levels. Nitrogen and total proteins per cell decreased with increasing growth light in both species when grown under low nitrogen media. Surprisingly, low nitrogen increased the cellular allocation to RUBISCO and the rate of electron transport away from Photosystem II for the smaller diatom under low growth light, and for the larger diatom across the range of growth lights. Low nitrogen decreased the growth rate of the smaller diatom, particularly under higher light, but stimulated the growth rate of the larger diatom. Our results show that the high nitrogen in common growth media favours the growth rate of a small diatom but inhibits growth of a larger species.

  4. Mothers' birth weight and survival of their offspring: population based study.

    PubMed

    Skjaerven, R; Wilcox, A J; Oyen, N; Magnus, P

    1997-05-10

    To test the hypothesis that a baby's survival is related to the mother's birth weight. Population based dataset for two generations. Population registry in Norway. All birth records for women born in Norway since 1967 were linked to births during 1981-94, thereby forming 105104 mother-offspring units. Perinatal mortality specific for weight for offspring in groups of maternal birth weight (with 500 g categories in both). A mother's birth weight was strongly associated with the weight of her baby. Maternal birth weight was associated with perinatal survival of her baby only for mothers with birth weights under 2000 g. These mothers were more likely to lose a baby in the perinatal period (odds ratio 2.3, 95% confidence interval 1.4 to 3.7). Among mothers with a birth weight over 2000 g there was no overall association between mother's weight and infant survival. There was, however, a strong interaction between mother's birth weight, infant birth weight, and infant survival. Mortality among small babies was much higher for those whose mothers had been large at birth. For example, babies weighing 2500-2999 g had a threefold higher mortality if their mother's birth weight had been high (> or = 4000 g) than if the mother had been small (2500-2999 g). Mothers who weighed less than 2000 g at birth have a higher risk of losing their own babies. For mothers who weighed > or = 2000 g their birth weight provides a benchmark for judging the growth of their offspring. Babies who are small relative to their mother's birth weight are at increased risk of mortality.

  5. Light intensity of 5 or 20 lux on broiler behavior, welfare and productivity.

    PubMed

    Rault, Jean-Loup; Clark, Katie; Groves, Peter J; Cronin, Greg M

    2017-04-01

    Light intensity can influence broiler behavior, but discrepancies in the scientific literature remain. Furthermore, few studies have investigated the welfare implications induced by varying light intensity. We investigated the effects of providing 5 or 20 lux light intensity on broiler behavior, welfare and productivity. A total of 1,872 Ross 308 broilers of mixed sex were studied across 2 replicates. Treatments began on d 8 with one of 2 light intensity levels: 5 lux or 20 lux, using LED lights on a 16L:8D photoperiod with 30 min sunrise and sunset periods. Production data, behavioral activity, and plasma samples for corticosterone concentration analysis were collected weekly from 8 to 46 d of age. Eye weight was collected at 42 d of age. Leg strength was assessed at 35, 42 and 45 d of age using the latency to lie test and leg and foot conditions (foot pad dermatitis, hock burn, leg straightness) were assessed at 46 d. Live weight differed between light treatments, with broilers kept at 20 lux being lighter than broilers kept at 5 lux at 46 d of age (males: -5.1%, females: -2.8%, P < 0.0001), despite no significant differences in feed intake. However, broilers kept at 20 lux were more active during the photophase than broilers kept at 5 lux throughout the rearing period (P < 0.0001). Eye weight was also on average 5% lighter for broilers kept at 20 lux compared to 5 lux (P = 0.001). Nonetheless, there was no significant effect of light intensity on other measures of broiler welfare: mortality and culls, plasma corticosterone concentrations, or latency to lie reflective of leg strength. Hence, broilers kept at 20 lux compared to 5 lux were found to be more active, had slower growth, and had lighter eye weight, but other welfare measures reflective of biological functioning or leg health did not show significant changes. © 2016 Poultry Science Association Inc.

  6. Inkjet-Printed Small-Molecule Organic Light-Emitting Diodes: Halogen-Free Inks, Printing Optimization, and Large-Area Patterning.

    PubMed

    Zhou, Lu; Yang, Lei; Yu, Mengjie; Jiang, Yi; Liu, Cheng-Fang; Lai, Wen-Yong; Huang, Wei

    2017-11-22

    Manufacturing small-molecule organic light-emitting diodes (OLEDs) via inkjet printing is rather attractive for realizing high-efficiency and long-life-span devices, yet it is challenging. In this paper, we present our efforts on systematical investigation and optimization of the ink properties and the printing process to enable facile inkjet printing of conjugated light-emitting small molecules. Various factors on influencing the inkjet-printed film quality during the droplet generation, the ink spreading on the substrates, and its solidification processes have been systematically investigated and optimized. Consequently, halogen-free inks have been developed and large-area patterning inkjet printing on flexible substrates with efficient blue emission has been successfully demonstrated. Moreover, OLEDs manufactured by inkjet printing the light-emitting small molecules manifested superior performance as compared with their corresponding spin-cast counterparts.

  7. Light and Color Research Continues in Arkansas.

    ERIC Educational Resources Information Center

    Sydoriak, Diane

    1984-01-01

    Describes a research project that will measure whether student achievement, blood pressure, height, and weight gain are influenced by the choice of color and/or the source of artificial light in the classroom. Four third-grade classrooms will be the treatment groups involving two colors and three different artificial light sources. (MLF)

  8. In Situ Formation of an Azo Bridge on Proteins Controllable by Visible Light.

    PubMed

    Hoppmann, Christian; Maslennikov, Innokentiy; Choe, Senyon; Wang, Lei

    2015-09-09

    Optical modulation of proteins provides superior spatiotemporal resolution for understanding biological processes, and photoswitches built on light-sensitive proteins have been significantly advancing neuronal and cellular studies. Small molecule photoswitches could complement protein-based switches by mitigating potential interference and affording high specificity for modulation sites. However, genetic encodability and responsiveness to nonultraviolet light, two desired properties possessed by protein photoswitches, are challenging to be engineered into small molecule photoswitches. Here we developed a small molecule photoswitch that can be genetically installed onto proteins in situ and controlled by visible light. A pentafluoro azobenzene-based photoswitchable click amino acid (F-PSCaa) was designed to isomerize in response to visible light. After genetic incorporation into proteins via the expansion of the genetic code, F-PSCaa reacts with a nearby cysteine within the protein generating an azo bridge in situ. The resultant bridge is switchable by visible light and allows conformation and binding of CaM to be regulated by such light. This photoswitch should prove valuable in optobiology for its minimal interference, site flexibility, genetic encodability, and response to the more biocompatible visible light.

  9. Childhood and adolescent obesity: how many extra calories are responsible for excess of weight?

    PubMed

    Pereira, Helen Rose C; Bobbio, Tatiana Godoy; Antonio, Maria Ângela R G M; Barros Filho, Antônio de Azevedo

    2013-06-01

    To review the main articles on energy imbalance and obesity in order to quantify the daily energy surplus associated with weight gain in children and adolescents. Articles published in the last ten years, indexed in electronic databases Medline (Pubmed) and SciELO-Br. In the Medline database, the descriptor "energy gap" was used and describes the energy values ​​associated with changes in body weight in individuals or populations. In SciELO-Br database, the descriptors "obesity", "energy metabolism", "energy balance", and "energy imbalance" were used, once it was not possible to find national articles discussing the energy gap. In the pediatric population, four studies were performed and indicate that children and adolescents are gradually gaining weight due to a small, but persistent, daily positive energy balance of 70 to 160kcal above the total energy suitable for growth. The results suggest that small changes in daily eating behavior as well as physical activity would be enough to prevent future weight gain in this population. gradual weight gain can be explained by small daily average of positive energy balance, from 70 to 160kcal above the total energy suitable for growth. The incentive to small changes in eating behavior and physical activities that promotes daily reduction of 160kcal can be an accessible practice in order to block weight gain in this population.

  10. Postmenstrual age correlates to indices of protein metabolism in very low birth weight infants.

    PubMed

    Boehm, G; Räihä, N C

    1993-04-01

    In 14 infants who were normal in weight for gestational age and 14 infants who were small for gestational age, the plasma essential amino acid profiles and serum urea concentrations were studied between the 30th and 46th weeks of postmenstrual age. All infants were of very low birth weight (< 1,500 g) and were fed with fresh human milk fortified with 6 g freeze-dried human milk per 100 ml (mean protein intake 3.1 g/kg/day, mean energy intake 130 kcal/kg/day). With the exception of threonine, all measured plasma essential amino acid concentrations increased significantly with increasing postmenstrual age (appropriate for gestational age infants: r = 0.861, p < 0.01; small for gestational age infants: r = 0.772, p < 0.001). No differences in this increase could be found between the infants who were small or appropriate for gestational age. The serum urea concentrations also increased with increasing postmenstrual age without differences between the study groups (appropriate for gestational age infants: r = 0.658, p < 0.01; small for gestational age infants: r = 0.604, p < 0.05). The results indicate that very low birth weight infants of similar weights may have very different protein requirements, depending on their postmenstrual ages. Thus, postmenstrual age is of greater importance than birth weight when protein nutrition is planned for very low birth weight infants.

  11. Detection of quantitative trait loci causing abnormal spermatogenesis and reduced testis weight in the small testis (Smt) mutant mouse.

    PubMed

    Bolor, Hasbaira; Wakasugi, Noboru; Zhao, Wei Dong; Ishikawa, Akira

    2006-04-01

    The small testis (Smt) mutant mouse is characterized by a small testis of one third to one half the size of a normal testis, and its spermatogenesis is mostly arrested at early stages of meiosis, although a small number of spermatocytes at the late prophase of meiosis and a few spermatids can sometimes be seen. We performed quantitative trait locus (QTL) analysis of these spermatogenic traits and testis weight using 221 F2 males obtained from a cross between Smt and MOM (Mus musculus molossinus) mice. At the genome-wide 5% level, we detected two QTLs affecting meiosis on chromosomes 4 and 13, and two QTLs for paired testis weight as a percentage of body weight on chromosomes 4 and X. In addition, we found several QTLs for degenerated germ cells and multinuclear giant cells on chromosomes 4, 7 and 13. Interestingly, for cell degeneration, the QTL on chromosome 13 interacted epistatically with the QTL on chromosome 4. These results reveal polygenic participation in the abnormal spermatogenesis and small testis size in the Smt mutant.

  12. Multiple approaches for enhancing all-organic electronics photoluminescent sensors: simultaneous oxygen and pH monitoring.

    PubMed

    Liu, Rui; Xiao, Teng; Cui, Weipan; Shinar, Joseph; Shinar, Ruth

    2013-05-17

    Key issues in using organic light emitting diodes (OLEDs) as excitation sources in structurally integrated photoluminescence (PL)-based sensors are the low forward light outcoupling, the OLEDs' broad electroluminescence (EL) bands, and the long-lived remnant EL that follows an EL pulse. The outcoupling issue limits the detection sensitivity (S) as only ~20% of the light generated within standard OLEDs can be forward outcoupled and used for sensor probe excitation. The EL broad band interferes with the analyte-sensitive PL, leading to a background that reduces S and dynamic range. In particular, these issues hinder designing compact sensors, potentially miniaturizable, that are devoid of optical filters and couplers. We address these shortcomings by introducing easy-to-employ multiple approaches for outcoupling improvement, PL enhancement, and background EL reduction leading to novel, compact all-organic device architectures demonstrated for simultaneous monitoring of oxygen and pH. The sensor comprises simply-fabricated, directionally-emitting, narrower-band, multicolor microcavity OLED excitation and small molecule- and polymer-based organic photodetectors (OPDs) with a more selective spectral response. Additionally, S and PL intensity for oxygen are enhanced by using polystyrene (PS):polyethylene glycol (PEG) blends as the sensing film matrix. By utilizing higher molecular weight PS, the ratio τ0/τ100 (PL decay time τ at 0% O2/τ at 100% O2) that is often used to express S increases ×1.9 to 20.7 relative to the lower molecular weight PS, where this ratio is 11.0. This increase reduces to ×1.7 when the PEG is added (τ0/τ100=18.2), but the latter results in an increase ×2.7 in the PL intensity. The sensor's response time is <10s in all cases. The microporous structure of these blended films, with PEG decorating PS pores, serves a dual purpose. It results in light scattering that reduces the EL that is waveguided in the substrate of the OLEDs and consequently enhances light outcoupling from the OLEDs by ~60%, and it increases the PL directed toward the OPD. The multiple functional structures of multicolor microcavity OLED pixels/microporous scattering films/OPDs enable generation of enhanced individually addressable sensor arrays, devoid of interfering issues, for O2 and pH as well as for other analytes and biochemical parameters. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Near-infrared light-activated red-emitting upconverting nanoplatform for T1-weighted magnetic resonance imaging and photodynamic therapy.

    PubMed

    Tang, Xiang-Long; Wu, Jun; Lin, Ben-Lan; Cui, Sheng; Liu, Hong-Mei; Yu, Ru-Tong; Shen, Xiao-Dong; Wang, Ting-Wei; Xia, Wei

    2018-05-12

    Photodynamic therapy (PDT) has increasingly become an efficient and attractive cancer treatment modality based on reactive oxygen species (ROS) that can induce tumor death after irradiation with ultraviolet or visible light. Herein, to overcome the limited tissue penetration in traditional PDT, a novel near-infrared (NIR) light-activated NaScF 4 : 40% Yb, 2% Er@CaF 2 upconversion nanoparticle (rUCNP) is successfully designed and synthesized. Chlorin e6, a photosensitizer and a chelating agent for Mn 2+ , is loaded into human serum albumin (HSA) that further conjugates onto rUCNPs. To increase the ability to target glioma tumor, an acyclic Arg-Gly-Asp peptide (cRGDyK) is linked to rUCNPs@HSA(Ce6-Mn). This nanoplatform enables efficient adsorption and conversion of NIR light (980 nm) into bright red emission (660 nm), which can trigger the photosensitizer Ce6-Mn complex for PDT and T 1 -weighted magnetic resonance imaging (T 1 -weighted MRI) for glioma diagnosis. Our in vitro and in vivo experiments demonstrate that NIR light-activated and glioma tumor-targeted PDT can generate large amounts of intracellular ROS that induce U87 cell apoptosis and suppress glioma tumor growth owing to the deep tissue penetration of irradiated light and excellent tumor-targeting ability. Thus, this nanoplatform holds potential for applications in T 1 -weighted MRI diagnosis and PDT of glioma for antitumor therapy. A near-infrared (NIR) light-activated nanoplatform for photodynamic therapy (PDT) was designed and synthesized. The Red-to-Green (R/G) ratio of NaScF 4 : 40% Yb, 2% Er almost reached 9, a value that was much higher than that of a traditional Yb/Er-codoped upconversion nanoparticle (rUCNP). By depositing a CaF 2 shell, the red-emission intensities of the rUCNPs were seven times strong as that of NaScF 4 : 40% Yb, 2% Er. The enhanced red-emitting rUCNPs could be applied in many fields such as bioimaging, controlled release, and real-time diagnosis. The nanoplatform had a strong active glioma-targeting ability, and all results achieved on subcutaneous glioma demonstrated that our NIR light-activated red-emitting upconverting nanoplatform was efficient for PDT. By loading Ce6-Mn complex into rUCNPs@HSA-RGD, the nanoplatform could be used as a T 1 -weighted magnetic resonance imaging agent for tumor diagnosis. Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  14. Development of High-power LED Lighting Luminaires Using Loop Heat Pipe

    NASA Astrophysics Data System (ADS)

    Huang, Bin-Juine; Huang, Huan-Hsiang; Chen, Chun-Wei; Wu, Min-Sheng

    High-power LED should reject about 6 times of heat of the conventional lighting device and keep the LED junction temperature below 80°C to assure reliability and low light decay. In addition, no fan is allowed and the heat dissipation design should not interfere with the industrial design of lighting fixture and have a light weight. This thus creates an extreme thermal management problem. The present study has shown that, using a special heat dissipation technology (loop heat pipe), the high-power LED lighting luminaire with input power from 36 to 150W for outdoor and indoor applications can be achieved with light weight, among 0.96 to 1.57 kg per 1,000 lumen of net luminous flux output from the luminaire. The loop heat pipe uses a flexible connecting pipe as the condenser which can be wounded around the reflector of the luminaire to dissipate the heat to the ambient air by natural convection. For roadway or street lighting application, the present study shows that a better optical design of LED lamps can further result in power consumption reduction, based on the same illumination on road surface. The high-power LED luminaries developed in the present study have shown that the energy saving is > 50% in road lighting applications as compared to sodium light or > 70% compared to mercury light.

  15. Assessment of minimum permissible geometrical parameters of a near-to-eye display.

    PubMed

    Valyukh, Sergiy; Slobodyanyuk, Oleksandr

    2015-07-20

    Light weight and small dimensions are some of the most important characteristics of near-to-eye displays (NEDs). These displays consist of two basic parts: a microdisplay for generating an image and supplementary optics in order to see the image. Nowadays, the pixel size of microdisplays may be less than 4 μm, which makes the supplementary optics the major factor in defining restrictions on a NED dimensions or at least on the distance between the microdisplay and the eye. The goal of the present work is to find answers to the following two questions: how small this distance can be in principle and what is the microdisplay maximum resolution that stays effective to see through the supplementary optics placed in immediate vicinity of the eye. To explore the first question, we consider an aberration-free magnifier, which is the initial stage in elaboration of a real optical system. In this case, the paraxial approximation and the transfer matrix method are ideal tools for simulation of light propagation from the microdisplay through the magnifier and the human eye's optical system to the retina. The human eye is considered according to the Gullstrand model. Parameters of the magnifier, its location with respect to the eye and the microdisplay, and the depth of field, which can be interpreted as the tolerance of the microdisplay position, are determined and discussed. The second question related to the microdisplay maximum resolution is investigated by using the principles of wave optics.

  16. Recording epileptic activity with MEG in a light-weight magnetic shield.

    PubMed

    De Tiège, Xavier; Op de Beeck, Marc; Funke, Michael; Legros, Benjamin; Parkkonen, Lauri; Goldman, Serge; Van Bogaert, Patrick

    2008-12-01

    Ten patients with focal epilepsy were studied with magnetoencephalography (MEG) to determine if a new light-weight magnetically shielded room (lMSR) provides sufficient attenuation of magnetic interference to detect and localize the magnetic correlates of epileptic activity. Interictal MEG epileptic events co-localizing with the presumed location of the epileptogenic zone were found in all patients. MEG measurements performed in the lMSR provide an adequate signal-to-noise ratio for non-invasive localization of epileptic foci.

  17. Superconductor lunar telescopes --Abstract only

    NASA Technical Reports Server (NTRS)

    Chen, P. C.; Pitts, R.; Shore, S.; Oliversen, R.; Stolarik, J.; Segal, K.; Hojaji, H.

    1994-01-01

    We propose a new type of telescope designed specifically for the lunar environment of high vacuum and low temperature. Large area UV-Visible-IR telescope arrays can be built with ultra-light-weight replica optics. High T(sub c) superconductors provide support, steering, and positioning. Advantages of this approach are light-weight payload compatible with existing launch vehicles, configurable large area optical arrays, no excavation or heavy construction, and frictionless electronically controlled mechanisms. We have built a prototype and will be demonstarting some of its working characteristics.

  18. Superconductor lunar telescopes --Abstract only

    NASA Astrophysics Data System (ADS)

    Chen, P. C.; Pitts, R.; Shore, S.; Oliversen, R.; Stolarik, J.; Segal, K.; Hojaji, H.

    1994-06-01

    We propose a new type of telescope designed specifically for the lunar environment of high vacuum and low temperature. Large area UV-Visible-IR telescope arrays can be built with ultra-light-weight replica optics. High Tc superconductors provide support, steering, and positioning. Advantages of this approach are light-weight payload compatible with existing launch vehicles, configurable large area optical arrays, no excavation or heavy construction, and frictionless electronically controlled mechanisms. We have built a prototype and will be demonstarting some of its working characteristics.

  19. Review of space radiation interaction with ZERODUR

    NASA Astrophysics Data System (ADS)

    Carré, Antoine; Westerhoff, Thomas; Hull, Tony; Doyle, D.

    2017-09-01

    ZERODUR has been and is still being successfully used as mirror substrates for a large number of space missions. Improvements in CNC machining at SCHOTT allow to achieve extremely light weighted substrates incorporating very thin ribs and face sheets. This paper is reviewing data published on the interaction of space radiation with ZERODUR. Additionally, this paper reports on considerations and experiments which are needed to confidently apply an updated model on ZERODUR behavior under space radiation for extremely light weighted ZERODUR substrates.

  20. Exploring the Specifications of Spatial Adjacencies and Weights in Bayesian Spatial Modeling with Intrinsic Conditional Autoregressive Priors in a Small-area Study of Fall Injuries

    PubMed Central

    Law, Jane

    2016-01-01

    Intrinsic conditional autoregressive modeling in a Bayeisan hierarchical framework has been increasingly applied in small-area ecological studies. This study explores the specifications of spatial structure in this Bayesian framework in two aspects: adjacency, i.e., the set of neighbor(s) for each area; and (spatial) weight for each pair of neighbors. Our analysis was based on a small-area study of falling injuries among people age 65 and older in Ontario, Canada, that was aimed to estimate risks and identify risk factors of such falls. In the case study, we observed incorrect adjacencies information caused by deficiencies in the digital map itself. Further, when equal weights was replaced by weights based on a variable of expected count, the range of estimated risks increased, the number of areas with probability of estimated risk greater than one at different probability thresholds increased, and model fit improved. More importantly, significance of a risk factor diminished. Further research to thoroughly investigate different methods of variable weights; quantify the influence of specifications of spatial weights; and develop strategies for better defining spatial structure of a map in small-area analysis in Bayesian hierarchical spatial modeling is recommended. PMID:29546147

  1. Cellular telephone-based radiation sensor and wide-area detection network

    DOEpatents

    Craig, William W [Pittsburg, CA; Labov, Simon E [Berkeley, CA

    2006-12-12

    A network of radiation detection instruments, each having a small solid state radiation sensor module integrated into a cellular phone for providing radiation detection data and analysis directly to a user. The sensor module includes a solid-state crystal bonded to an ASIC readout providing a low cost, low power, light weight compact instrument to detect and measure radiation energies in the local ambient radiation field. In particular, the photon energy, time of event, and location of the detection instrument at the time of detection is recorded for real time transmission to a central data collection/analysis system. The collected data from the entire network of radiation detection instruments are combined by intelligent correlation/analysis algorithms which map the background radiation and detect, identify and track radiation anomalies in the region.

  2. Superconducting light generator for large offshore wind turbines

    NASA Astrophysics Data System (ADS)

    Sanz, S.; Arlaban, T.; Manzanas, R.; Tropeano, M.; Funke, R.; Kováč, P.; Yang, Y.; Neumann, H.; Mondesert, B.

    2014-05-01

    Offshore wind market demands higher power rate and reliable turbines in order to optimize capital and operational cost. These requests are difficult to overcome with conventional generator technologies due to a significant weight and cost increase with the scaling up. Thus superconducting materials appears as a prominent solution for wind generators, based on their capacity to held high current densities with very small losses, which permits to efficiently replace copper conductors mainly in the rotor field coils. However the state-of-the-art superconducting generator concepts still seem to be expensive and technically challenging for the marine environment. This paper describes a 10 MW class novel direct drive superconducting generator, based on MgB2 wires and a modular cryogen free cooling system, which has been specifically designed for the offshore wind industry needs.

  3. Compact dry chemistry instruments.

    PubMed

    Terashima, K; Tatsumi, N

    1999-01-01

    Compact dry chemistry instruments are designed for use in point-of-care-testing (POCT). These instruments have a number of advantages, including light weight, compactness, ease of operation, and the ability to provide accurate results in a short time with a very small sample volume. On the other hand, reagent costs are high compared to liquid method. Moreover, differences in accuracy have been found between dry chemistry and the liquid method in external quality assessment scheme. This report examines reagent costs and shows how the total running costs associated with dry chemistry are actually lower than those associated with the liquid method. This report also describes methods for minimizing differences in accuracy between dry chemistry and the liquid method. Use of these measures is expected to increase the effectiveness of compact dry chemistry instruments in POCT applications.

  4. High resolution, high sensitivity, dynamic distributed structural monitoring using optical frequency domain reflectometry

    NASA Astrophysics Data System (ADS)

    Kreger, Stephen T.; Sang, Alex K.; Garg, Naman; Michel, Julia

    2013-05-01

    Fiber-optic ultrasonic transducers are an important component of an active ultrasonic testing system for structural health monitoring. Fiber-optic transducers have several advantages such as small size, light weight, and immunity to electromagnetic interference that make them much more attractive than the current available piezoelectric transducers, especially as embedded and permanent transducers in active ultrasonic testing for structural health monitoring. In this paper, a distributed fiber-optic laser-ultrasound generation based on the ghost-mode of tilted fiber Bragg gratings is studied. The influences of the laser power and laser pulse duration on the laser-ultrasound generation are investigated. The results of this paper are helpful to understand the working principle of this laser-ultrasound method and improve the ultrasonic generation efficiency.

  5. Study of distributed fiber-optic laser-ultrasound generation based on ghost-mode of tilted fiber Bragg gratings

    NASA Astrophysics Data System (ADS)

    Tian, Jiajun; Zhang, Qi; Han, Ming

    2013-05-01

    Fiber-optic ultrasonic transducers are an important component of an active ultrasonic testing system for structural health monitoring. Fiber-optic transducers have several advantages such as small size, light weight, and immunity to electromagnetic interference that make them much more attractive than the current available piezoelectric transducers, especially as embedded and permanent transducers in active ultrasonic testing for structural health monitoring. In this paper, a distributed fiber-optic laser-ultrasound generation based on the ghost-mode of tilted fiber Bragg gratings is studied. The influences of the laser power and laser pulse duration on the laser-ultrasound generation are investigated. The results of this paper are helpful to understand the working principle of this laser-ultrasound method and improve the ultrasonic generation efficiency.

  6. Miniature, ruggedized data collector

    NASA Astrophysics Data System (ADS)

    Jackson, Scott; Calcutt, Wade; Knobler, Ron; Jones, Barry; Klug, Robert

    2009-05-01

    McQ has developed a miniaturized, programmable, ruggedized data collector intended for use in weapon testing or data collection exercises that impose severe stresses on devices under test. The recorder is designed to survive these stresses which include acceleration and shock levels up to 100,000 G. The collector acquires and stores up to four channels of signal data to nonvolatile memory for later retrieval by a user. It is small (< 7 in3), light weight (< 1 lb), and can operate from various battery chemistries. A built-in menuing system, accessible via a USB interface, allows the user to configure parameters of the recorder operation, such as channel gain, filtering, and signal offsets, and also to retrieve recorded data for analysis. An overview of the collector, its features, performance, and potential uses, is presented.

  7. Mars Relay Satellite: Key to Enabling Low-Cost Exploration Missions

    NASA Technical Reports Server (NTRS)

    Hastrup, R.; Cesarone, R.; Miller, A.

    1993-01-01

    Recently, there has been increasing evidence of a renewed focus on Mars exploration both by NASA and the international community. The thrust of this renewed interest appears to be manifesting itself in numerous low-cost missions employing small, light weight elements, which utilize advanced technologies including integrated microelectronics. A formidable problem facing these low-cost missions is communications with Earth. Providing adequate direct-link performance has very significant impacts on spacecraft power, pointing, mass and overall complexity. Additionally, for elements at or near the surface of Mars, there are serious connectivity constraints, especially at higher latitudes, which lose view of Earth for up to many months at a time. This paper will discuss the role a Mars relay satellite can play in enabling and enhancing low-cost missions to Mars...

  8. Cellular telephone-based radiation detection instrument

    DOEpatents

    Craig, William W [Pittsburg, CA; Labov, Simon E [Berkeley, CA

    2011-06-14

    A network of radiation detection instruments, each having a small solid state radiation sensor module integrated into a cellular phone for providing radiation detection data and analysis directly to a user. The sensor module includes a solid-state crystal bonded to an ASIC readout providing a low cost, low power, light weight compact instrument to detect and measure radiation energies in the local ambient radiation field. In particular, the photon energy, time of event, and location of the detection instrument at the time of detection is recorded for real time transmission to a central data collection/analysis system. The collected data from the entire network of radiation detection instruments are combined by intelligent correlation/analysis algorithms which map the background radiation and detect, identify and track radiation anomalies in the region.

  9. Cellular telephone-based wide-area radiation detection network

    DOEpatents

    Craig, William W [Pittsburg, CA; Labov, Simon E [Berkeley, CA

    2009-06-09

    A network of radiation detection instruments, each having a small solid state radiation sensor module integrated into a cellular phone for providing radiation detection data and analysis directly to a user. The sensor module includes a solid-state crystal bonded to an ASIC readout providing a low cost, low power, light weight compact instrument to detect and measure radiation energies in the local ambient radiation field. In particular, the photon energy, time of event, and location of the detection instrument at the time of detection is recorded for real time transmission to a central data collection/analysis system. The collected data from the entire network of radiation detection instruments are combined by intelligent correlation/analysis algorithms which map the background radiation and detect, identify and track radiation anomalies in the region.

  10. Optimization of Smart Structure for Improving Servo Performance of Hard Disk Drive

    NASA Astrophysics Data System (ADS)

    Kajiwara, Itsuro; Takahashi, Masafumi; Arisaka, Toshihiro

    Head positioning accuracy of the hard disk drive should be improved to meet today's increasing performance demands. Vibration suppression of the arm in the hard disk drive is very important to enhance the servo bandwidth of the head positioning system. In this study, smart structure technology is introduced into the hard disk drive to suppress the vibration of the head actuator. It has been expected that the smart structure technology will contribute to the development of small and light-weight mechatronics devices with the required performance. First, modeling of the system is conducted with finite element method and modal analysis. Next, the actuator location and the control system are simultaneously optimized using genetic algorithm. Vibration control effect with the proposed vibration control mechanisms has been evaluated by some simulations.

  11. Plankton Dynamics and Mesoscale Turbulence

    DTIC Science & Technology

    2010-06-29

    transformation of inorganic materials and light into living matter by photosynthesis ) is operated mainly by small, unicellular algae that float freely in the...ecosystems, primary production (the transformation of inorganic materials and light into living matter by photosynthesis ) is operated mainly by small...them into biomass via photosynthesis . The main limiting factors for phytoplankton growth are light and nutrient availability; for this reason

  12. All plastic ultra-small size imaging lens unit fabrication and evaluation for endoscope

    NASA Astrophysics Data System (ADS)

    Ishii, Kenta; Okamoto, Dai; Ushio, Makoto; Tai, Hidetoshi; Nishihara, Atsuhiko; Tokuda, Kimio; Kawai, Shinsuke; Kitagawa, Seiichiro

    2017-02-01

    There is demand for small-size lens units for endoscope and industrial applications. Polished glass lenses with a diameter of 1 - 2mm exist, however plastic lenses similar in size are not commonplace. For low-cost, light-weight, and mass production, plastic lens fabrication is extremely beneficial. Especially, in the medical field, there is strong demand for disposable lens unit for endoscopes which prevent contamination due to reuse of the lens. Therefore, high mass producible and low cost becomes increasingly important. This paper reports our findings on injection-molded ultra-small size plastic lens units with a diameter of 1.3mm and total thickness of 1.4mm. We performed optical design, injection molding, and lens unit assembly for injection moldable, high imaging performance ultra-small sized lens units. We prioritize a robust product design, considering injection molding properties and lens unit assembly, with feedback from molding simulations reflected into the optical design. A mold capable of high precision lens positioning is used to fabricate the lenses and decrease the variability of the assembly. The geometric dimensions of the resulting lenses, are measured and used in the optical simulation to validate the optical performance, and a high agreement is reported. The injection molding of the lens and the assembly of the lens unit is performed with high precision, and results in high optical performance.

  13. A study of glasses-type color CGH using a color filter considering reduction of blurring

    NASA Astrophysics Data System (ADS)

    Iwami, Saki; Sakamoto, Yuji

    2009-02-01

    We have developed a glasses-type color computer generated hologram (CGH) by using a color filter. The proposed glasses consist of two "lenses" made of overlapping holograms and color filters. The holograms, which are calculated to reconstruct images in each primary color, are divided to small areas, which we called cells, and superimposed on one hologram. In the same way, colors of the filter correspond to the hologram cells. We can configure it very simply without a complex optical system, and the configuration yields a small and light weight system suitable for glasses. When the cell is small enough, the colors are mixed and reconstructed color images are observed. In addition, color expression of reconstruction images improves, too. However, using small cells blurrs reconstructed images because of the following reasons: (1) interference between cells because of the correlation with the cells, and (2) reduction of resolution caused by the size of the cell hologram. We are investigating in order to make a hologram that has high resolution reconstructed color images without ghost images. In this paper, we discuss (1) the details of the proposed glasses-type color CGH, (2) appropriate cell size for an eye system, (3) effects of cell shape on the reconstructed images, and (4) a new method to reduce the blurring of the images.

  14. Compound cycle engine for helicopter application

    NASA Technical Reports Server (NTRS)

    Castor, Jere G.

    1986-01-01

    The Compound Cycle Engine (CCE) is a highly turbocharged, power compounded, ultra-high power density, light-weight diesel engine. The turbomachinery is similar to a moderate pressure ratio, free power turbine engine and the diesel core is high speed and a low compression ratio. This engine is considered a potential candidate for future military light helicopter applications. This executive summary presents cycle thermodynamic (SFC) and engine weight analyses performed to establish general engine operating parameters and configuration. An extensive performance and weight analysis based on a typical two hour helicopter (+30 minute reserve) mission determined final conceptual engine design. With this mission, CCE performance was compared to that of a T-800 class gas turbine engine. The CCE had a 31% lower-fuel consumption and resulted in a 16% reduction in engine plus fuel and fuel tank weight. Design SFC of the CCE is 0.33 lb-HP-HR and installed wet weight is 0.43 lbs/HP. The major technology development areas required for the CCE are identified and briefly discussed.

  15. A Mission-Adaptive Variable Camber Flap Control System to Optimize High Lift and Cruise Lift-to-Drag Ratios of Future N+3 Transport Aircraft

    NASA Technical Reports Server (NTRS)

    Urnes, James, Sr.; Nguyen, Nhan; Ippolito, Corey; Totah, Joseph; Trinh, Khanh; Ting, Eric

    2013-01-01

    Boeing and NASA are conducting a joint study program to design a wing flap system that will provide mission-adaptive lift and drag performance for future transport aircraft having light-weight, flexible wings. This Variable Camber Continuous Trailing Edge Flap (VCCTEF) system offers a lighter-weight lift control system having two performance objectives: (1) an efficient high lift capability for take-off and landing, and (2) reduction in cruise drag through control of the twist shape of the flexible wing. This control system during cruise will command varying flap settings along the span of the wing in order to establish an optimum wing twist for the current gross weight and cruise flight condition, and continue to change the wing twist as the aircraft changes gross weight and cruise conditions for each mission segment. Design weight of the flap control system is being minimized through use of light-weight shape memory alloy (SMA) actuation augmented with electric actuators. The VCCTEF program is developing better lift and drag performance of flexible wing transports with the further benefits of lighter-weight actuation and less drag using the variable camber shape of the flap.

  16. A gravimetric method for the measurement of total spontaneous activity in rats.

    PubMed

    Biesiadecki, B J; Brand, P H; Koch, L G; Britton, S L

    1999-10-01

    Currently available methods for the measurement of spontaneous activity of laboratory animals require expensive, specialized equipment and may not be suitable for use in low light conditions with nocturnal species. We developed a gravimetric method that uses common laboratory equipment to quantify the total spontaneous activity of rats and is suitable for use in the dark. The rat in its home cage is placed on a top-loading electronic balance interfaced to a computer. Movements are recorded by the balance as changes in weight and transmitted to the computer at 10 Hz. Data are analyzed on-line to derive the absolute value of the difference in weight between consecutive samples, and the one-second average of the absolute values is calculated. The averages are written to file for off-line analysis and summed over the desired observation period to provide a measure of total spontaneous activity. The results of in vitro experiments demonstrated that: 1) recorded weight changes were not influenced by position of the weight on the bottom of the cage, 2) values recorded from a series of weight changes were not significantly different from the calculated values, 3) the constantly decreasing force exerted by a swinging pendulum placed on the balance was accurately recorded, 4) the measurement of activity was not influenced by the evaporation of a fluid such as urine, and 5) the method can detect differences in the activity of sleeping and waking rats over a 10-min period, as well as during 4-hr intervals recorded during active (night-time) and inactive (daytime) periods. These results demonstrate that this method provides an inexpensive, accurate, and noninvasive method to quantitate the spontaneous activity of small animals.

  17. Multiple-Fiber-Optic Probe For Light-Scattering Measurements

    NASA Technical Reports Server (NTRS)

    Dhadwal, Harbans Singh; Ansari, Rafat R.

    1996-01-01

    Multiple-fiber-optical probe developed for use in measuring light scattered at various angles from specimens of materials. Designed for both static and dynamic light-scattering measurements of colloidal dispersions. Probe compact, rugged unit containing no moving parts and remains stationary during operation. Not restricted to operation in controlled, research-laboratory environment. Positioned inside or outside light-scattering chamber. Provides simultaneous measurements at small angular intervals over range of angles, made to include small scattering angles by orienting probe in appropriate direction.

  18. Patterns of gestational weight gain and birthweight outcomes in the Eunice Kennedy Shriver National Institute of Child Health and Human Development Fetal Growth Studies-Singletons: a prospective study.

    PubMed

    Pugh, Sarah J; Albert, Paul S; Kim, Sungduk; Grobman, William; Hinkle, Stefanie N; Newman, Roger B; Wing, Deborah A; Grantz, Katherine L

    2017-09-01

    Inadequate or excessive total gestational weight gain is associated with increased risks of small- and large-for-gestational-age births, respectively, but evidence is sparse regarding overall and trimester-specific patterns of gestational weight gain in relation to these risks. Characterizing the interrelationship between patterns of gestational weight gain across trimesters can reveal whether the trajectory of gestational weight gain in the first trimester sets the path for gestational weight gain in subsequent trimesters, thereby serving as an early marker for at-risk pregnancies. We sought to describe overall trajectories of gestational weight gain across gestation and assess the risk of adverse birthweight outcomes associated with the overall trajectory and whether the timing of gestational weight gain (first vs second/third trimester) is differentially associated with adverse outcomes. We conducted a secondary analysis of a prospective cohort of 2802 singleton pregnancies from 12 US prenatal centers (2009 through 2013). Small and large for gestational age were calculated using sex-specific birthweight references <5th, <10th, or ≥90th percentiles, respectively. At each of the research visits, women's weight was measured following a standardized anthropometric protocol. Maternal weight at antenatal clinical visits was also abstracted from the prenatal records. Semiparametric, group-based, latent class, trajectory models estimated overall gestational weight gain and separate first- and second-/third-trimester trajectories to assess tracking. Robust Poisson regression was used to estimate the relative risk of small- and large-for-gestational-age outcomes by the probability of trajectory membership. We tested whether relationships were modified by prepregnancy body mass index. There were 2779 women with a mean of 15 (SD 5) weights measured across gestation. Four distinct gestational weight gain trajectories were identified based on the lowest Bayesian information criterion value, classifying 10.0%, 41.8%, 39.2%, and 9.0% of the population from lowest to highest weight gain trajectories, with an inflection at 14 weeks. The average rate in each trajectory group from lowest to highest for 0-<14 weeks was -0.20, 0.04, 0.21, and 0.52 kg/wk and for 14-39 weeks was 0.29, 0.48, 0.63, and 0.79 kg/wk, respectively; the second lowest gaining trajectory resembled the Institute of Medicine recommendations and was designated as the reference with the other trajectories classified as low, moderate-high, or high. Accuracy of assignment was assessed and found to be high (median posterior probability 0.99, interquartile range 0.99-1.00). Compared with the referent trajectory, a low overall trajectory, but not other trajectories, was associated with a 1.55-fold (95% confidence interval, 1.06-2.25) and 1.58-fold (95% confidence interval, 0.88-2.82) increased risk of small-for-gestational-age <10th and <5th, respectively, while a moderate-high and high trajectory were associated with a 1.78-fold (95% confidence interval, 1.31-2.41) and 2.45-fold (95% confidence interval, 1.66-3.61) increased risk of large for gestational age, respectively. In a separate analysis investigating whether early (<14 weeks) gestational weight gain tracked with later (≥14 weeks) gestational weight gain, only 49% (n = 127) of women in the low first-trimester trajectory group continued as low in the second/third trimester, and had a 1.59-fold increased risk of small for gestational age; for the other 51% (n = 129) of women without a subsequently low second-/third-trimester gestational weight gain trajectory, there was no increased risk of small for gestational age (relative risk, 0.75; 95% confidence interval, 0.47-1.38). Prepregnancy body mass index did not modify the association between gestational weight gain trajectory and small for gestational age (P = 0.52) or large for gestational age (P = .69). Our findings are reassuring for women who experience weight loss or excessive weight gain in the first trimester; however, the risk of small or large for gestational age is significantly increased if women gain weight below or above the reference trajectory in the second/third trimester. Published by Elsevier Inc.

  19. Using environmental and growth characteristics of plants to detect long-term changes in response to atmospheric pollution: some examples from British beechwoods.

    PubMed

    Ling, K A

    2003-07-01

    This study uses the Ellenberg system of plant indicator values, along with Grime et al.'s plant growth strategy values, to investigate the nature of temporal changes in the composition of ground flora in two beechwoods in the Cotswolds region of the UK, currently receiving atmospheric inputs of nitrogen in excess of critical loads. The woods, first surveyed in the early 1960s, were resurveyed in 1998 using the original sampling protocol. Temporal changes in the abundance of individual species at Blackstable West Wood indicate changes in light over time, although decreases in sun species, and both increases and decreases in shade species suggest that this change has been patchy. Analysis of changes in plant community as represented by weighted and unweighted quadrat Ellenberg and CSR scores have yielded more significant results. Blackstable West Wood shows increases in nitrophilic, moist-soil and competitive species accompanied by a decline in stress-tolerant species. In Buckholt Top Wood there has been an increase in sun and moist-soil species, a decrease in competitive species and, when weighted Ellenberg scores are considered, an increase in acid-tolerant species. These changes indicate both the impact of woodland management by selective felling and an underlying influence of enhanced atmospheric deposition especially of nitrogen pollutants. It is concluded that quadrat mean scores are a useful tool especially where few individual species have undergone large temporal changes in abundance. However, lack of correlations between quadrat Ellenberg scores for pH and light on one hand, and their equivalents measured in the field, i.e. soil pH and surrogates for light, such as distance to the nearest tree and tree density, suggest that this approach may not be sensitive enough to pick up small-scale, within site variations. Although harder to interpret, plant strategy scores were found to be a useful additional descriptor, encapsulating a plant's response to a range of environmental factors.

  20. Physics of a rapid CD4 lymphocyte count with colloidal gold.

    PubMed

    Hansen, P; Barry, D; Restell, A; Sylvia, D; Magnin, O; Dombkowski, D; Preffer, F

    2012-03-01

    The inherent surface charges and small diameters that confer colloidal stability to gold particle conjugates (immunogold) are detrimental to rapid cell surface labeling and distinct cluster definition in flow cytometric light scatter assays. Although the inherent immunogold surface charge prevents self aggregation when stored in liquid suspension, it also slows binding to cells to timeframes of hours and inhibits cell surface coverage. Although the small diameter of immunogold particles prevents settling when in liquid suspension, small particles have small light scattering cross sections and weak light scatter signals. We report a new, small particle lyophilized immunogold reagent that maintains activity after 42°C storage for a year and can be rapidly dissolved into stable liquid suspension for use in labelling cells with larger particle aggregates that have enhanced scattering cross section. Labeling requires less than 1 min at 20°C, which is ∼30 times faster than customary fluorescent antibody labeling. The labeling step involves neutralizing the surface charge of immunogold and creating specifically bound aggregates of gold on the cell surface. This process provides distinct side-scatter cluster separation with blue laser light at 488 nm, which is further improved by using red laser light at 640 nm. Similar comparisons using LED light sources showed less improvement with red light, thereby indicating that coherent light scatter is of significance in enhancing side-scatter cluster separation. The physical principles elucidated here for this technique are compatible with most flow cytometers; however, future studies of its clinical efficacy should be of primary interest in point-of-care applications where robust reagents and rapid results are important. Copyright © 2011 International Society for Advancement of Cytometry.

  1. Non-Visual Effects of Classroom Lighting on Children.

    ERIC Educational Resources Information Center

    Hathaway, Warren E.

    1993-01-01

    A two-year study in Alberta on the effects of classroom lighting found that elementary school students exposed to full-spectrum lighting with measurable ultraviolet output had fewer dental caries, larger gains in height and weight, larger gains in achievement, and better attendance. Students exposed to high-pressure sodium vapor lamps had the…

  2. Particle sizing by weighted measurements of scattered light

    NASA Technical Reports Server (NTRS)

    Buchele, Donald R.

    1988-01-01

    A description is given of a measurement method, applicable to a poly-dispersion of particles, in which the intensity of scattered light at any angle is weighted by a factor proportional to that angle. Determination is then made of four angles at which the weighted intensity is four fractions of the maximum intensity. These yield four characteristic diameters, i.e., the diameters of the volume/area mean (D sub 32 the Sauter mean) and the volume/diameter mean (D sub 31); the diameters at cumulative volume fractions of 0.5 (D sub v0.5 the volume median) and 0.75 (D sub v0.75). They also yield the volume dispersion of diameters. Mie scattering computations show that an average diameter less than three micrometers cannot be accurately measured. The results are relatively insensitive to extraneous background light and to the nature of the diameter distribution. Also described is an experimental method of verifying the conclusions by using two microscopic slides coated with polystyrene microspheres to simulate the particles and the background.

  3. Algal culture studies related to a closed ecological life support system

    NASA Technical Reports Server (NTRS)

    Radmer, R.; Behrens, P.; Fernandez, E.; Ollinger, O.; Howell, C.

    1984-01-01

    Studies on the steady-state long-term (4 month) culture of Scenedesmus obliquus algae, maintained in an annular air-lift column operated as a turbidostat, were carried out to evaluate the life-supporting possibilities of this system. Chlorophyll production and cell number as functions of the dry weight were linear at constant illumination. Productivity (measured as the product of dry weight, mg/ml, and the growth rate, ml/hr) vs. dry weight rose linearly until the cell density reached a level at which light became limiting (89 percent absorption of the photosynthetically active radiation). In the initial, linear portion of the curve, the productivity was limited by cell growth at the given light intensity. The maximum dilution rate of the system corresponded to the doubling time of 13.4 hr, about half the maximum rate, with a productivity of 80 percent of the maximum theoretical productivity. The high light utilization efficiencies were contributed by the low (10 percent of full sunlight) incident intensities.

  4. Five-class height-weight mean and SD system applying Estonian reference values of height-weight mean and SD for systematization of seventeen-year-old conscripts' anthropometric data.

    PubMed

    Lintsi, Mart; Kaarma, Helje; Aunapuu, Marina; Arend, Andres

    2007-03-01

    A study of 739 conscripts aged 17 years from the town of Tartu and from the Tartu county was performed. Height, weight, 33 anthropometric measurements and 12 skinfolds were measured. The data were classified into five height-weight mean and SD-classes applying the Estonian reference values for this age and sex (Grünberg et al. 1998). There were 3 classes with conformity between height and weight class: 1--small (small height and small weight), 2--medium (medium height and medium weight), 3--large (large height and large weight), 4--weight class dominating (pyknomorphic) and 5--height class dominating (leptomorphic). It was found, that in classes 1, 2 and 3 the height and weight increase was in accordance with the increase in all heights, breadths and depths, circumferences, skinfolds, body fat, muscle and bone mass. In class 4 circumferences, skinfolds, body fat and muscle mass were bigger. In class 5 all heights and the relative bone mass were bigger. The present investigation confirms the assumption that the five height-weight mean and SD five-class system applying the Estonian reference values for classifying the anthropometric variables is suitable for seventeen-year-old conscripts. As well the border values of 5%, 50% and 95% for every anthropometrical variable in the five-classes were calculated, which may be helpful for practical classifying.

  5. Light enhanced the accumulation of total fatty acids (TFA) and docosahexaenoic acid (DHA) in a newly isolated heterotrophic microalga Crypthecodinium sp. SUN.

    PubMed

    Sun, Dongzhe; Zhang, Zhao; Mao, Xuemei; Wu, Tao; Jiang, Yue; Liu, Jin; Chen, Feng

    2017-03-01

    In the present study, light illumination was found to be efficient in elevating the total fatty acid content in a newly isolated heterotrophic microalga, Crypthecodinium sp. SUN. Under light illumination, the highest total fatty acid and DHA contents were achieved at 96h as 24.9% of dry weight and 82.8mgg -1 dry weight, respectively, which were equivalent to 1.46-fold and 1.68-fold of those under the dark conditions. The elevation of total fatty acid content was mainly contributed by an increase of neutral lipids at the expense of starches. Moreover, light was found to alter the cell metabolism and led to a higher specific growth rate, higher glucose consumption rate and lower non-motile cell percentage. This is the first report that light can promote the total fatty acids accumulation in Crypthecodinium without growth inhibition. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Project Ares 3

    NASA Technical Reports Server (NTRS)

    Raymer, Dan; Russell, Phyllis; Fox, Tim; Meyers, Doug; Lovric, Steven; Grabow, Robert; Epp, Manfred; Wynn, Warren, Jr.; Mako, Zoltan; Linzner, Gunther

    1992-01-01

    The mission of Project Ares is to design and fabricate an Earth prototype, autonomous flying rover capable of flying on the Martian surface. The project was awarded to California State University, Northridge (CSUN) in 1989 where an in-depth paper study was completed. The second year's group, Project Ares 2, designed and fabricated a full-scale flight demonstration aircraft. Project Ares 3, the third and final group, is responsible for propulsion system design and installation, controls and instrumentation, and high altitude testing. The propulsion system consists of a motor and its power supply, geartrain, and propeller. The motor is a four-brush DC motor powered by a 50-V NiCd battery supply. A pulley and belt arrangement is used for the geartrain and includes light weight, low temperature materials. The propeller is constructed from composite materials which ensures high strength and light weight, and is specifically developed to provide thrust at extremely high altitudes. The aircraft is controlled with a ground-based radio control system and an autopilot which will activate in the event that the control signal is lost. A transponder is used to maintain radar contact for ground tracking purposes. The aircraft possesses a small, onboard computer for collecting and storing flight data. To safeguard the possibility of computer failure, all flight data is transmitted to a ground station via a telemetry system. An initial, unpowered, low-level test flight was completed in August of 1991. Testing of systems integration in the second low-level test flight resulted in loss of elevator control which caused considerable damage on landing. Complete failure analysis and repairs are scheduled for September of 1992.

  7. A portable single-sided magnet system for remote NMR measurements of pulmonary function.

    PubMed

    Dabaghyan, Mikayel; Muradyan, Iga; Hrovat, Alan; Butler, James; Frederick, Eric; Zhou, Feng; Kyriazis, Angelos; Hardin, Charles; Patz, Samuel; Hrovat, Mirko

    2014-12-01

    In this work, we report initial results from a light-weight, low field magnetic resonance device designed to make relative pulmonary density measurements at the bedside. The development of this device necessarily involves special considerations for the magnet, RF and data acquisition schemes as well as a careful analysis of what is needed to provide useful information in the ICU. A homogeneous field region is created remotely from the surface of the magnet such that when the magnet is placed against the chest, an NMR signal is measured from a small volume in the lung. In order to achieve portability, one must trade off field strength and therefore spatial resolution. We report initial measurements from a ping-pong ball size region in the lung as a function of lung volume. As expected, we measured decreased signal at larger lung volumes since lung density decreases with increasing lung volume. Using a CPMG sequence with ΔTE=3.5 ms and a 20 echo train, a signal to noise ratio ~1100 was obtained from an 8.8mT planar magnet after signal averaging for 43 s. This is the first demonstration of NMR measurements made on a human lung with a light-weight planar NMR device. We argue that very low spatial resolution measurements of different lobar lung regions will provide useful diagnostic information for clinicians treating Acute Respiratory Distress Syndrome as clinicians want to avoid ventilator pressures that cause either lung over distension (too much pressure) or lung collapse (too little pressure). Copyright © 2014 John Wiley & Sons, Ltd.

  8. A portable single-sided magnet system for remote NMR measurements of pulmonary function

    PubMed Central

    Mikayel, Dabaghyan; Iga, Muradyan; James, Butler; Eric, Frederick; Feng, Zhou; Angelos, Kyriazis; Charles, Hardin; Samuel, Patz; Mirko, Hrovat

    2014-01-01

    In this work, we report initial results from a light-weight, low field magnetic resonance device designed to make relative pulmonary density measurements at the bedside. The development of this device necessarily involves special considerations for the magnet, RF and data acquisition schemes as well as a careful analysis of what is needed to provide useful information in the ICU. A homogeneous field region is created remotely from the surface of the magnet such that when the magnet is placed against the chest, an NMR signal is measured from a small volume in the lung. In order to achieve portability, one must trade off field strength and therefore spatial resolution. We report initial measurements from a ping-pong ball size region in the lung as a function of lung volume. As expected, we measured decreased signal at larger lung volumes since lung density decreases with increasing lung volume. Using a CPMG sequence with ΔTE=3.5 ms and a 20 echo train, a signal to noise ratio ~1100 was obtained from an 8.8mT planar magnet after signal averaging for 43 s. This is the first demonstration of NMR measurements made on a human lung with a light-weight planar NMR device. We argue that very low spatial resolution measurements of different lobar lung regions will provide useful diagnostic information for clinicians treating Acute Respiratory Distress Syndrome as clinicians want to avoid ventilator pressures that cause either lung over distension (too much pressure) or lung collapse (too little pressure). PMID:24953556

  9. Child nutritional status and child growth in Kenya: socioeconomic determinants.

    PubMed

    Deolalikar, A B

    1996-01-01

    The determinants of weight and height are explored using nationally representative data for Kenya. The author also uses recall data on child birth weights to estimate conditional reduced-form demand relations for weight gain among 7907 children aged 0-5 years. Maternal education was found to be a significant determinant of weight, height, and weight gain, with secondary schooling having larger, but not significantly different effects than primary schooling. Per capita household expenditure is highly significant but with only small numerical effects. Birth weight has a large, negative effect upon subsequent weight gain, indicating almost complete catch-up growth by age one. The effect becomes more negative when birth weight is treated as an endogenous variable. There is no evidence of any catch-up growth beyond age three. The study results indicate that small deficits in birth weight are not likely to be permanent, with infants making up for birth weight deficits completely within the first year of life through biological catch-up growth.

  10. Optimizing LED lighting for space plant growth unit: Joint effects of photon flux density, red to white ratios and intermittent light pulses

    NASA Astrophysics Data System (ADS)

    Avercheva, O. V.; Berkovich, Yu. A.; Konovalova, I. O.; Radchenko, S. G.; Lapach, S. N.; Bassarskaya, E. M.; Kochetova, G. V.; Zhigalova, T. V.; Yakovleva, O. S.; Tarakanov, I. G.

    2016-11-01

    The aim of this work were to choose a quantitative optimality criterion for estimating the quality of plant LED lighting regimes inside space greenhouses and to construct regression models of crop productivity and the optimality criterion depending on the level of photosynthetic photon flux density (PPFD), the proportion of the red component in the light spectrum and the duration of the duty cycle (Chinese cabbage Brassica chinensis L. as an example). The properties of the obtained models were described in the context of predicting crop dry weight and the optimality criterion behavior when varying plant lighting parameters. Results of the fractional 3-factor experiment demonstrated the share of the PPFD level participation in the crop dry weight accumulation was 84.4% at almost any combination of other lighting parameters, but when PPFD value increased up to 500 μmol m-2 s-1 the pulse light and supplemental light from red LEDs could additionally increase crop productivity. Analysis of the optimality criterion response to variation of lighting parameters showed that the maximum coordinates were the following: PPFD = 500 μmol m-2 s-1, about 70%-proportion of the red component of the light spectrum (PPFDLEDred/PPFDLEDwhite = 1.5) and the duty cycle with a period of 501 μs. Thus, LED crop lighting with these parameters was optimal for achieving high crop productivity and for efficient use of energy in the given range of lighting parameter values.

  11. Maternal and neonatal outcomes among obese women with weight gain below the new Institute of Medicine recommendations.

    PubMed

    Blomberg, Marie

    2011-05-01

    To estimate whether weight loss or low gestational weight gain in class I-III obese women is associated with adverse maternal and neonatal outcomes compared with gestational weight gain within the new Institute of Medicine recommendations. This was a population-based cohort study, which included 32,991 obesity class I, 10,068 obesity class II, and 3,536 obesity class III women who were divided into four gestational weight gain categories. Women with low (0-4.9 kg) or no gestational weight gain were compared with women gaining the recommended 5-9 kg concerning obstetric and neonatal outcome after suitable adjustments. Women in obesity class III who lost weight during pregnancy had a decreased risk of cesarean delivery (24.4%; odds ratio [OR] 0.77, 95% confidence interval [CI] 0.60-0.99), large-for-gestational-age births (11.2%, OR 0.64, 95% CI 0.46-0.90), and no significantly increased risk for pre-eclampsia, excessive bleeding during delivery, instrumental delivery, low Apgar score, or fetal distress compared with obese (class III) women gaining within the Institute of Medicine recommendations. There was an increased risk for small for gestational age, 3.7% (OR 2.34, 95% CI 1.15-4.76) among women in obesity class III losing weight, but there was no significantly increased risk of small for gestational age in the same group with low weight gain. Obese women (class II and III) who lose weight during pregnancy seem to have a decreased or unaffected risk for cesarean delivery, large for gestational age, pre-eclampsia, excessive postpartum bleeding, instrumental delivery, low Apgar score, and fetal distress. The twofold increased risk of small for gestational age in obesity class III and weight loss (3.7%) is slightly above the overall prevalence of small-for-gestational-age births in Sweden (3.6%).

  12. Supplemental Upward Lighting from Underneath to Obtain Higher Marketable Lettuce (Lactuca sativa) Leaf Fresh Weight by Retarding Senescence of Outer Leaves.

    PubMed

    Zhang, Geng; Shen, Shanqi; Takagaki, Michiko; Kozai, Toyoki; Yamori, Wataru

    2015-01-01

    Recently, the so-called "plant factory with artificial lighting" (PFAL) approach has been developed to provide safe and steady food production. Although PFALs can produce high-yielding and high-quality plants, the high plant density in these systems accelerates leaf senescence in the bottom (or outer) leaves owing to shading by the upper (or inner) leaves and by neighboring plants. This decreases yield and increases labor costs for trimming. Thus, the establishment of cultivation methods to retard senescence of outer leaves is an important research goal to improve PFAL yield and profitability. In the present study, we developed an LED lighting apparatus that would optimize light conditions for PFAL cultivation of a leafy vegetable. Lettuce (Lactuca sativa L.) was hydroponically grown under white, red, or blue LEDs, with light provided from above (downward), with or without supplemental upward lighting from underneath the plant. White LEDs proved more appropriate for lettuce growth than red or blue LEDs, and the supplemental lighting retarded the senescence of outer leaves and decreased waste (i.e., dead or low-quality senescent leaves), leading to an improvement of the marketable leaf fresh weight.

  13. High-speed pre-clinical brain imaging using pulsed laser diode based photoacoustic tomography (PLD-PAT) system

    NASA Astrophysics Data System (ADS)

    Upputuri, Paul Kumar; Pramanik, Manojit

    2016-03-01

    Photoacoustic tomography (PAT) is a promising biomedical imaging modality for small animal imaging, breast cancer imaging, monitoring of vascularisation, tumor angiogenesis, blood oxygenation, total haemoglobin concentration etc. The existing PAT systems that uses Q-switched Nd:YAG and OPO nanosecond lasers have limitations in clinical applications because they are expensive, non-potable and not suitable for real-time imaging due to their low pulse repetition rate. Low-energy pulsed near-infrared diode laser which are low-cost, compact, and light-weight (<200 grams), can be used as an alternate. In this work, we present a photoacoustic tomography system with a pulsed laser diode (PLD) that can nanosecond pulses with pulse energy 1.3 mJ/pulse at ~803 nm wavelength and 7000 Hz repetition rate. The PLD is integrated inside a single-detector circular scanning geometric system. To verify the high speed imaging capabilities of the PLD-PAT system, we performed in vivo experimental results on small animal brain imaging using this system. The proposed system is portable, low-cost and can provide real-time imaging.

  14. High-throughput liquid-absorption air-sampling apparatus and methods

    DOEpatents

    Zaromb, Solomon

    2000-01-01

    A portable high-throughput liquid-absorption air sampler [PHTLAAS] has an asymmetric air inlet through which air is drawn upward by a small and light-weight centrifugal fan driven by a direct current motor that can be powered by a battery. The air inlet is so configured as to impart both rotational and downward components of motion to the sampled air near said inlet. The PHTLAAS comprises a glass tube of relatively small size through which air passes at a high rate in a swirling, highly turbulent motion, which facilitates rapid transfer of vapors and particulates to a liquid film covering the inner walls of the tube. The pressure drop through the glass tube is <10 cm of water, usually <5 cm of water. The sampler's collection efficiency is usually >20% for vapors or airborne particulates in the 2-3.mu. range and >50% for particles larger than 4.mu.. In conjunction with various analyzers, the PHTLAAS can serve to monitor a variety of hazardous or illicit airborne substances, such as lead-containing particulates, tritiated water vapor, biological aerosols, or traces of concealed drugs or explosives.

  15. A potential for overestimating the absolute magnitudes of second virial coefficients by small-angle X-ray scattering.

    PubMed

    Scott, David J; Patel, Trushar R; Winzor, Donald J

    2013-04-15

    Theoretical consideration is given to the effect of cosolutes (including buffer and electrolyte components) on the determination of second virial coefficients for proteins by small-angle X-ray scattering (SAXS)-a factor overlooked in current analyses in terms of expressions for a two-component system. A potential deficiency of existing practices is illustrated by reassessment of published results on the effect of polyethylene glycol concentration on the second virial coefficient for urate oxidase. This error reflects the substitution of I(0,c3,0), the scattering intensity in the limit of zero scattering angle and solute concentration, for I(0,0,0), the corresponding parameter in the limit of zero cosolute concentration (c3) as well. Published static light scattering results on the dependence of the apparent molecular weight of ovalbumin on buffer concentration are extrapolated to zero concentration to obtain the true value (M2) and thereby establish the feasibility of obtaining the analogous SAXS parameter, I(0,0,0), experimentally. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. The Unmanned Aerial System SUMO: an alternative measurement tool for polar boundary layer studies

    NASA Astrophysics Data System (ADS)

    Mayer, S.; Jonassen, M. O.; Reuder, J.

    2012-04-01

    Numerical weather prediction and climate models face special challenges in particular in the commonly stable conditions in the high-latitude environment. For process studies as well as for model validation purposes in-situ observations in the atmospheric boundary layer are highly required, but difficult to retrieve. We introduce a new measurement system for corresponding observations. The Small Unmanned Meteorological Observer SUMO consists of a small and light-weight auto-piloted model aircraft, equipped with a meteorological sensor package. SUMO has been operated in polar environments, among others during IPY on Spitsbergen in the year 2009 and has proven its capabilities for atmospheric measurements with high spatial and temporal resolution even at temperatures of -30 deg C. A comparison of the SUMO data with radiosondes and tethered balloons shows that SUMO can provide atmospheric profiles with comparable quality to those well-established systems. Its high data quality allowed its utilization for evaluation purposes of high-resolution model runs performed with the Weather Research and Forecasting model WRF and for the detailed investigation of an orographically modified flow during a case study.

  17. Design methodology for micro-discrete planar optics with minimum illumination loss for an extended source.

    PubMed

    Shim, Jongmyeong; Park, Changsu; Lee, Jinhyung; Kang, Shinill

    2016-08-08

    Recently, studies have examined techniques for modeling the light distribution of light-emitting diodes (LEDs) for various applications owing to their low power consumption, longevity, and light weight. The energy mapping technique, a design method that matches the energy distributions of an LED light source and target area, has been the focus of active research because of its design efficiency and accuracy. However, these studies have not considered the effects of the emitting area of the LED source. Therefore, there are limitations to the design accuracy for small, high-power applications with a short distance between the light source and optical system. A design method for compensating for the light distribution of an extended source after the initial optics design based on a point source was proposed to overcome such limits, but its time-consuming process and limited design accuracy with multiple iterations raised the need for a new design method that considers an extended source in the initial design stage. This study proposed a method for designing discrete planar optics that controls the light distribution and minimizes the optical loss with an extended source and verified the proposed method experimentally. First, the extended source was modeled theoretically, and a design method for discrete planar optics with the optimum groove angle through energy mapping was proposed. To verify the design method, design for the discrete planar optics was achieved for applications in illumination for LED flash. In addition, discrete planar optics for LED illuminance were designed and fabricated to create a uniform illuminance distribution. Optical characterization of these structures showed that the design was optimal; i.e., we plotted the optical losses as a function of the groove angle, and found a clear minimum. Simulations and measurements showed that an efficient optical design was achieved for an extended source.

  18. Compensation for the phase-type spatial periodic modulation of the near-field beam at 1053 nm

    NASA Astrophysics Data System (ADS)

    Gao, Yaru; Liu, Dean; Yang, Aihua; Tang, Ruyu; Zhu, Jianqiang

    2017-10-01

    A phase-only spatial light modulator is used to provide and compensate for the spatial periodic modulation (SPM) of the near-field beam at the near infrared at 1053nm wavelength with an improved iterative weight-based method. The transmission characteristics of the incident beam has been changed by a spatial light modulator (SLM) to shape the spatial intensity of the output beam. The propagation and reverse propagation of the light in free space are two important processes in the iterative process. The based theory is the beam angular spectrum transmit formula (ASTF) and the principle of the iterative weight-based method. We have made two improvements to the originally proposed iterative weight-based method. We select the appropriate parameter by choosing the minimum value of the output beam contrast degree and use the MATLAB built-in angle function to acquire the corresponding phase of the light wave function. The required phase that compensates for the intensity distribution of the incident SPM beam is iterated by this algorithm, which can decrease the magnitude of the SPM of the intensity on the observation plane. The experimental results show that the phase-type SPM of the near-field beam is subject to a certain restriction. We have also analyzed some factors that make the results imperfect. The experiment results verifies the possible applicability of this iterative weight-based method to compensate for the SPM of the near-field beam.

  19. Relationship between weight of rescuer and quality of chest compression during cardiopulmonary resuscitation

    PubMed Central

    2014-01-01

    Background According to the guidelines for cardiopulmonary resuscitation (CPR), the rotation time for chest compression should be about 2 min. The quality of chest compressions is related to the physical fitness of the rescuer, but this was not considered when determining rotation time. The present study aimed to clarify associations between body weight and the quality of chest compression and physical fatigue during CPR performed by 18 registered nurses (10 male and 8 female) assigned to light and heavy groups according to the average weight for each sex in Japan. Methods Five-minute chest compressions were then performed on a manikin that was placed on the floor. Measurement parameters were compression depth, heart rate, oxygen uptake, integrated electromyography signals, and rating of perceived exertion. Compression depth was evaluated according to the ratio (%) of adequate compressions (at least 5 cm deep). Results The ratio of adequate compressions decreased significantly over time in the light group. Values for heart rate, oxygen uptake, muscle activity defined as integrated electromyography signals, and rating of perceived exertion were significantly higher for the light group than for the heavy group. Conclusion Chest compression caused increased fatigue among the light group, which consequently resulted in a gradual fall in the quality of chest compression. These results suggested that individuals with a lower body weight should rotate at 1-min intervals to maintain high quality CPR and thus improve the survival rates and neurological outcomes of victims of cardiac arrest. PMID:24957919

  20. Stabilization of polyaniline solutions through additives

    DOEpatents

    Wrobleski, D.A.; Benicewicz, B.C.

    1996-12-10

    A stabilized non-conductive polyaniline solution comprising from about 1 to about 10 percent by weight polyaniline or a polyaniline derivative, from about 90 to about 99 percent by weight N-methylpyrrolidone, and from about 0.5 percent by weight to about 15 percent by weight of a solution stabilizing additive selected from the group consisting of hindered amine light stabilizers, polymeric amines, and dialkylamines, percent by weight of additive based on the total weight of polyaniline or polyaniline derivative is provided together with a method for stabilizing a polyaniline solution. 4 figs.

  1. Stabilization of polyaniline solutions through additives

    DOEpatents

    Wrobleski, Debra A.; Benicewicz, Brian C.

    1996-01-01

    A stabilized non-conductive polyaniline solution comprising from about 1 to bout 10 percent by weight polyaniline or a polyaniline derivative, from about 90 to about 99 percent by weight N-methylpyrrolidone, and from about 0.5 percent by weight to about 15 percent by weight of a solution stabilizing additive selected from the group consisting of hindered amine light stabilizers, polymeric amines, and dialkylamines, percent by weight of additive based on the total weight of polyaniline or polyaniline derivative is provided together with a method for stabilizing a polyaniline solution.

  2. Trace element distribution in the rat cerebellum

    NASA Astrophysics Data System (ADS)

    Kwiatek, W. M.; Long, G. J.; Pounds, J. G.; Reuhl, K. R.; Hanson, A. L.; Jones, K. W.

    1990-04-01

    Spatial distributions and concentrations of trace elements (TE) in the brain are important because TE perform catalytic and structural functions in enzymes which regulate brain function and development. We have investigated the distributions of TE in rat cerebellum. Structures were sectioned and analyzed by the Synchrotron Radiation Induced X-ray Emission (SRIXE) method using the NSLS X-26 white-light microprobe facility. Advantages important for TE analysis of biological specimens with X-ray microscopy include short time of measurement, high brightness and flux, good spatial resolution, multielemental detection, good sensitivity, and nondestructive irradiation. Trace elements were measured in thin rat brain sections of 20 μm thickness. The analyses were performed on sample volumes as small as 0.2 nl with Minimum Detectable Limits (MDL) of 50 ppb wet weight for Fe, 100 ppb wet weight for Cu, and Zn, and 1 ppm wet weight for Pb. The distribution of TE in the molecular cell layer, granule cell layer and fiber tract of rat cerebella was investigated. Both point analyses and two-dimensional semiquantitative mapping of the TE distribution in a section were used. All analyzed elements were observed in each structure of the cerebellum except mercury which was not observed in granule cell layer or fiber tract. This approach permits an exacting correlation of the TE distribution in complex structure with the diet, toxic elements, and functional status of the animal.

  3. High Pressure Earth Storable Rocket Technology Program: Basic Program

    NASA Technical Reports Server (NTRS)

    Chazen, M. L.; Sicher, D.; Huang, D.; Mueller, T.

    1995-01-01

    The HIPES Program was conducted for NASA-LeRC by TRW. The Basic Program consisted of system studies, design of testbed engine, fabrication and testing of engine. Studies of both pressure-fed and pump-fed systems were investigated for N2O4 and both MMH and N2H4 fuels with the result that N2H4 provides the maximum payload for all satellites over MMH. The higher pressure engine offers improved performance with smaller envelope and associated weight savings. Pump-fed systems offer maximum payload for large and medium weight satellites while pressure-fed systems offer maximum payload for small light weight satellites. The major benefits of HIPES are high performance within a confined length maximizing payload for lightsats which are length (volume) constrained. Three types of thrust chambers were evaluated -- Copper heatsink at 400, 500 and 600 psia chamber pressures for performance/thermal; water cooled to determine heat absorbed to predict rhenium engine operation; and rhenium to validate the concept. The HIPES engine demonstrated very high performance at 50 lbf thrust (epsilon = 150) and Pc = 500 psia with both fuels: Isp = 337 sec using N2O4-N2H4 and ISP = 327.5 sec using N2O4-MMH indicating combustion efficiencies greater than 98%. A powder metallurgy rhenium engine demonstrated operation with high performance at Pc = 500 psia which indicated the viability of the concept.

  4. Analysis of the Relationship Between Vehicle Weight/Size and Safety, and Implications for Federal Fuel Economy Regulation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wenzel, Thomas P.

    This report analyzes the relationship between vehicle weight, size (wheelbase, track width, and their product, footprint), and safety, for individual vehicle makes and models. Vehicle weight and footprint are correlated with a correlation coefficient (R{sup 2}) of about 0.62. The relationship is stronger for cars (0.69) than for light trucks (0.42); light trucks include minivans, fullsize vans, truck-based SUVs, crossover SUVs, and pickup trucks. The correlation between wheelbase and track width, the components of footprint, is about 0.61 for all light vehicles, 0.62 for cars and 0.48 for light trucks. However, the footprint data used in this analysis does notmore » vary for different versions of the same vehicle model, as curb weight does; the analysis could be improved with more precise data on footprint for different versions of the same vehicle model. Although US fatality risk to drivers (driver fatalities per million registered vehicles) decreases as vehicle footprint increases, there is very little correlation either for all light vehicles (0.01), or cars (0.07) or trucks (0.11). The correlation between footprint and fatality risks cars impose on drivers of other vehicles is also very low (0.01); for trucks the correlation is higher (0.30), with risk to others increasing as truck footprint increases. Fatality risks reported here do not account for differences in annual miles driven, driver age or gender, or crash location by vehicle type or model. It is difficult to account for these factors using data on national fatal crashes because the number of vehicles registered to, for instance, young males in urban areas is not readily available by vehicle type or model. State data on all police-reported crashes can be used to estimate casualty risks that account for miles driven, driver age and gender, and crash location. The number of vehicles involved in a crash can act as a proxy of the number of miles a given vehicle type, or model, is driven per year, and is a preferable unit of exposure to a serious crash than the number of registered vehicles. However, because there are relatively few fatalities in the states providing crash data, we calculate casualty risks, which are the sum of fatalities and serious or incapacitating injuries, per vehicle involved in a crash reported to the police. We can account for driver age/gender and driving location effects by excluding from analysis crashes (and casualties) involving young males and the elderly, and occurring in very rural or very urban counties. Using state data on all police-reported crashes in five states, we find that excluding crashes involving young male and elderly drivers has little effect on casualty risk; however, excluding crashes that occurred in the most rural and most urban counties (based on population density) increases casualty risk for all vehicle types except pickups. This suggests that risks for pickups are overstated unless they account for the population density of the county in which the crashes occur. After removing crashes involving young males and elderly drivers, and those occurring in the most rural and most urban counties, we find that casualty risk in all light-duty vehicles tends to increase with increasing weight or footprint; however, the correlation (R{sup 2}) between casualty risk and vehicle weight is 0.31, while the correlation with footprint is 0.23. These relationships are stronger for cars than for light trucks. The correlation between casualty risk in frontal crashes and light-duty vehicle wheelbase is 0.12, while the correlation between casualty risk in left side crashes and track width is 0.36. We calculated separately the casualty risks vehicles impose on drivers of the other vehicles with which they crash. The correlation between casualty risk imposed by light trucks on drivers of other vehicles and light truck footprint is 0.15, while the correlation with light truck footprint is 0.33; risk imposed on others increases as light truck weight or footprint increases. Our analysis indicates that, after excluding crashes involving young male and elderly drivers, and crashes in very rural and very urban counties, and accounting for vehicle weight and footprint, sports cars, pickup trucks and truck-based SUVs have higher risk to their drivers than cars, while import luxury cars and crossover SUVs have lower risk to their drivers than cars. Similarly, pickups and sports cars impose a large casualty risk on drivers of other vehicles, after accounting for vehicle weight and footprint. Our analysis suggests that excluding young male and elderly drivers, and crashes in very rural and urban counties, accounting for vehicle weight, footprint, and type explains only about half of the variability in casualty risk to drivers, and to drivers of other vehicles, by vehicle model.« less

  5. Characterization of ribulose-1, 5-bisphosphate carboxylase/oxygenase and transcriptional analysis of its related genes in Saccharina japonica (Laminariales, Phaeophyta)

    NASA Astrophysics Data System (ADS)

    Shao, Zhanru; Liu, Fuli; Li, Qiuying; Yao, Jianting; Duan, Delin

    2014-03-01

    Saccharina japonica is a common macroalga in sublittoral communities of cold seawater environments, and consequently may have highly efficient ribulose-1, 5-bisphosphate carboxylase/oxygenase (Rubisco) activity for carbon assimilation. In our study, we cloned the full-length Rubisco gene from S. japonica ( SJ-rbc). It contained an open reading frame for a large subunit gene ( SJ — rbcL) of 1 467 bp, a small subunit gene ( SJ-rbcS) of 420 bp, and a SJ-rbcL/S intergenic spacer of 269 bp. The deduced peptides of SJ-rbcL and SJ-rbcS were 488 and 139 amino acids with theoretical molecular weights and isoelectric points of 53.97 kDa, 5.81 and 15.84 kDa, 4.71, respectively. After induction with 1 mmol/L isopropyl- β-D-thiogalactopyranoside for 5 h and purification by Ni2+ affinity chromatography, electrophoresis and western blot detection demonstrated successful expression of the 55 kDa SJ-rbcL protein. Real-time quantitative PCR showed that the mRNA levels of SJ-rbcL in gametophytes increased when transferred into normal growth conditions and exhibited diurnal variations: increased expression during the day but suppressed expression at night. This observation implied that Rubisco played a role in normal gametophytic growth and development. In juvenile sporophytes, mRNA levels of SJ-rbcL, carbonic anhydrase, Calvin-Benson-Bassham cycle-related enzyme, and chloroplast light-harvesting protein were remarkably increased under continuous light irradiance. Similarly, expression of these genes was up-regulated under blue light irradiance at 350 μmol/(m2·s). Our results indicate that long-term white light and short-term blue light irradiance enhances juvenile sporophytic growth by synergistic effects of various photosynthetic elements.

  6. Determination of the Charon/Pluto Mass Ratio from Center-of-Light Astrometry

    NASA Technical Reports Server (NTRS)

    Foust, Jeffrey A.; Elliot, J. L.; Olkin, Catherine B.; McDonald, Stephen W.; Dunham, Edward W.; Stone, Remington P. S.; McDonald, John S.; Stone, Ronald C.

    1997-01-01

    The Charon/Pluto mass ratio is a fundamental but poorly known parameter of the two-body system. Previous values for the mass ratio have ranged from 0.0837 plus or minus 0.0147 (Null et al., 1993, Astron. J. 105, 2319-2335) to 0.1566 plus or minus 0.0035 (Young et al., 1994, Icarus 108,186-199). We report here a new determination of the Charon/Pluto mass ratio, using five sets of groundbased images taken at four sites in support of Pluto occultation predictions. Unlike the Null et al. and Young et A determinations, where the centers of light for Pluto and Charon could be determined separately, this technique examines the motion of the center of light of the blended Pluto-Charon image. We compute the offsets of the observed center-of-light position of Pluto-Charon from the ephemeris position of the system and fit these offsets to a model of the Pluto-Charon system. The least-squares fits to the five data sets agree within their errors, and the weighted mean mass ratio is 0.117 plus or minus 0.006. The effects of errors in the Charon light fraction, semimajor axis, and ephemeris have been examined and are equal to only a small fraction of the formal error from the fit. This result is intermediate between those of Null et al., and Young et al. and matches a new value of 0.124 plus or minus 0.008 by Null and Owen (1996, Astron. J. 111, 1368-1381). The mass ratio and resulting individual masses and densities of Pluto and Charon are consistent with a collisional origin for the Pluto-Charon system.

  7. Improvements in Cardiovascular Risk Factors in Young Adults in a Randomized Trial of Approaches to Weight Gain Prevention

    PubMed Central

    Wing, Rena R.; Tate, Deborah F.; Garcia, Katelyn R.; Bahnson, Judy; Lewis, Cora E.; Espeland, Mark A.

    2017-01-01

    Objective Weight gain occurs commonly in young adults and increases cardiovascular (CVD) risk. We previously reported that two self-regulation interventions reduced weight gain relative to control. Here we examine whether these interventions also benefit CVD risk factors. Methods SNAP (Study of Novel Approaches to Weight Gain Prevention) was a randomized trial in 2 academic settings (N=599; 18–35 years; body mass index 21–30 kg/m2) comparing two interventions (Self-Regulation with Small Changes; Self-Regulation with Large Changes) and Control. Small Changes taught participants to make daily small changes (approximately 100 calorie) in intake and activity. Large Changes taught participants to initially lose 5–10 pounds to buffer anticipated weight gains. CVD risk factors were assessed at baseline and 2 years in 471 participants. Results Although Large Changes was associated with more beneficial changes in glucose, insulin, and HOMA-IR than Control, these differences were not significant after adjusting for multiple comparisons or 2-year weight change. Comparison of participants grouped by percent weight change baseline to 2 years showed significant differences for several CVD risk factors, with no interaction with treatment condition. Conclusions Magnitude of weight change, rather than specific weight gain prevention interventions, was related to changes in CVD risk factors in young adults. PMID:28782918

  8. Robust Small Target Co-Detection from Airborne Infrared Image Sequences.

    PubMed

    Gao, Jingli; Wen, Chenglin; Liu, Meiqin

    2017-09-29

    In this paper, a novel infrared target co-detection model combining the self-correlation features of backgrounds and the commonality features of targets in the spatio-temporal domain is proposed to detect small targets in a sequence of infrared images with complex backgrounds. Firstly, a dense target extraction model based on nonlinear weights is proposed, which can better suppress background of images and enhance small targets than weights of singular values. Secondly, a sparse target extraction model based on entry-wise weighted robust principal component analysis is proposed. The entry-wise weight adaptively incorporates structural prior in terms of local weighted entropy, thus, it can extract real targets accurately and suppress background clutters efficiently. Finally, the commonality of targets in the spatio-temporal domain are used to construct target refinement model for false alarms suppression and target confirmation. Since real targets could appear in both of the dense and sparse reconstruction maps of a single frame, and form trajectories after tracklet association of consecutive frames, the location correlation of the dense and sparse reconstruction maps for a single frame and tracklet association of the location correlation maps for successive frames have strong ability to discriminate between small targets and background clutters. Experimental results demonstrate that the proposed small target co-detection method can not only suppress background clutters effectively, but also detect targets accurately even if with target-like interference.

  9. Light Duty Truck Weight Reduction Evaluation

    DOT National Transportation Integrated Search

    1980-08-01

    This contract covers the identification of Types, Makes and Models which constitute the Light Truck world fleet. The attributes which describe the critical functional aspects of trucks of this size are established and specifications to define the att...

  10. Studying Phototropism Using a Small Growth Chamber.

    ERIC Educational Resources Information Center

    Fisher, Maryanna, F.; Llewellyn, Gerald C.

    1978-01-01

    Describes a simple and inexpensive way to construct two small growth chambers for studying phototropism in the science classroom. One chamber is designed to illustrate how plants grow around obstacles to reach light and the other to illustrate directional light responses. (HM)

  11. Changes in Energy Intake and Diet Quality during an 18-Month Weight-Management Randomized Controlled Trial in Adults with Intellectual and Developmental Disabilities.

    PubMed

    Ptomey, Lauren T; Steger, Felicia L; Lee, Jaehoon; Sullivan, Debra K; Goetz, Jeannine R; Honas, Jeffery J; Washburn, Richard A; Gibson, Cheryl A; Donnelly, Joseph E

    2018-06-01

    Previous research indicates that individuals with intellectual and developmental disabilities (IDDs) are at risk for poor diet quality. The purpose of this secondary analysis was to determine whether two different weight-loss diets affect energy intake, macronutrient intake, and diet quality as measured by the Healthy Eating Index-2010 (HEI-2010) during a 6-month weight-loss period and 12-month weight-management period, and to examine differences in energy intake, macronutrient intake, and HEI-2010 between groups. Overweight/obese adults with IDDs took part in an 18-month randomized controlled trial and were assigned to either an enhanced Stop Light Diet utilizing portion-controlled meals or a conventional diet consisting of reducing energy intake and following the 2010 Dietary Guidelines for Americans. Proxy-assisted 3-day food records were collected at baseline, 6 months, and 18 months, and were analyzed using Nutrition Data System for Research software. HEI-2010 was calculated using the data from Nutrition Data System for Research. The study took place from June 2011 through May 2014 in the greater Kansas City metropolitan area. This was a secondary analysis of a weight-management intervention for adults with IDDs randomized to an enhanced Stop Light Diet or conventional diet, to examine differences in energy intake, macronutrient intake, and HEI-2010 across time and between groups. Independent- and paired-samples t tests and general mixed modeling for repeated measures were performed to examine group differences and changes at baseline, 6 months, and 18 months between the enhanced Stop Light Diet and conventional diet groups. One hundred and forty six participants (57% female, mean±standard deviation age=36.2±12.0 years) were randomized to either the enhanced Stop Light Diet or conventional diet group (77 enhanced Stop Light Diet, 69 conventional diet) and provided data for analysis at baseline, 124 completed the 6-month weight-loss period, and 101 completed the 18-month study. Participants on the enhanced Stop Light Diet diet significantly reduced energy intake at 6 and 18 months (both P<0.001), but those on the conventional diet did not (both P=0.13). However, when accounting for age, sex, race, education level, and support level (mild vs moderate IDD), there was a significant decrease during the 18-month intervention in energy intake for the enhanced Stop Light Diet and conventional diet groups combined (P<0.01 for time effect), but no significant group difference in this change (P=0.39 for group-by-time interaction). There was no significant change in total HEI-2010 score at 6 and 18 months (P=0.05 and P=0.38 for the enhanced Stop Light Diet group; P=0.22 and P=0.17 for the conventional diet group), and no significant group difference at 6 and 18 months (P=0.08 and P=0.42). However, when participants' age, sex, race, education level, and support level were accounted for, mixed modeling indicated a significant increase in total HEI-2010 scores for the enhanced Stop Light Diet and conventional diet groups combined during the 18-month intervention (P=0.01 for time effect). The results of this study found that after controlling for demographic factors, individuals with IDDs can decrease their energy intake and increase their diet quality, with no significant differences between the enhanced Stop Light Diet and conventional diet groups. Copyright © 2018 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.

  12. Strength characteristics of light weight concrete blocks using mineral admixtures

    NASA Astrophysics Data System (ADS)

    Bhuvaneshwari, P.; Priyadharshini, U.; Gurucharan, S.; Mithunram, B.

    2017-07-01

    This paper presents an experimental study to investigate the characteristics of light weight concrete blocks. Cement was partially replaced with mineral admixtures like Fly ash (FA), limestone powder waste (LPW), Rice husk ash (RHA), sugarcane fiber waste (SCW) and Chrysopogonzizanioides (CZ). The maximum replacement level achieved was 25% by weight of cement and sand. Total of 56 cubes (150 mm x 150 mm x150 mm) and 18 cylinders (100mmφ and 50mm depth) were cast. The specimens being (FA, RHA, SCW, LPW, CZ, (FA-RHA), (FA-LPW), (FA-CZ), (LPW-CZ), (FA-SCW), (RHA-SCW)).Among the different combination, FA,FA-SCW,CZ,FA-CZ showed enhanced strength and durability, apart from achieving less density.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, Yung-Ting; Department of Electrical Engineering, Graduate Institute of Photonics and Optoelectronics, National Taiwan University, Taipei, Taiwan 10617, Taiwan; Liu, Shun-Wei

    Single-layer blue phosphorescence organic light emitting diodes (OLEDs) with either small-molecule or polymer hosts are fabricated using solution process and the performances of devices with different hosts are investigated. The small-molecule device exhibits luminous efficiency of 14.7 cd/A and maximum power efficiency of 8.39 lm/W, which is the highest among blue phosphorescence OLEDs with single-layer solution process and small molecular hosts. Using the same solution process for all devices, comparison of light out-coupling enhancement, with brightness enhancement film (BEF), between small-molecule and polymer based OLEDs is realized. Due to different dipole orientation and anisotropic refractive index, polymer-based OLEDs would trap less lightmore » than small molecule-based OLEDs internally, about 37% better based simulation results. In spite of better electrical and spectroscopic characteristics, including ambipolar characteristics, higher carrier mobility, higher photoluminescence quantum yield, and larger triplet state energy, the overall light out-coupling efficiency of small molecule-based devices is worse than that of polymer-based devices without BEF. However, with BEF for light out-coupling enhancement, the improved ratio in luminous flux and luminous efficiency for small molecule based device is 1.64 and 1.57, respectively, which are significantly better than those of PVK (poly-9-vinylcarbazole) devices. In addition to the theoretical optical simulation, the experimental data also confirm the origins of differential light-outcoupling enhancement. The maximum luminous efficiency and power efficiency are enhanced from 14.7 cd/A and 8.39 lm/W to 23 cd/A and 13.2 lm/W, respectively, with laminated BEF, which are both the highest so far for single-layer solution-process blue phosphorescence OLEDs with small molecule hosts.« less

  14. Application of lightweight materials in structure concept design of large-scale solar energy unmanned aerial vehicle

    NASA Astrophysics Data System (ADS)

    Zhang, Wei; Lv, Shengli; Guan, XiQi

    2017-09-01

    Carbon fiber composites and film materials can be effectively used in light aircraft structures, especially for solar unmanned aerial vehicles. The use of light materials can reduce the weight of the aircraft, but also can effectively improve the aircraft's strength and stiffness. The structure of the large aspect ratio solar energy UAV was analyzed in detail, taking Solar-impulse solar aircraft as an example. The solar energy UAV has a wing aspect ratio greater than 20, and the detailed digital model of the wing structure including beam, ribs and skin was built, also the Finite Element Method was applied to analyze the static and dynamic performance of the structure. The upper skin of the wing is covered with silicon solar cells, while the lower skin is light and transparent film. The single beam truss form of carbon fiber lightweight material is used in the wing structure. The wing beam is a box beam with rectangular cross sections. The box beam connected the front parts and after parts of the ribs together. The fuselage of the aircraft was built by space truss structure. According to the static and dynamic analysis with Finite Element method, it was found that the aircraft has a small wingtip deflection relative to the wingspan in the level flight state. The first natural frequency of the wing structure is pretty low, which is closed to the gust load.

  15. Infrared imaging-based combat casualty care system

    NASA Astrophysics Data System (ADS)

    Davidson, James E., Sr.

    1997-08-01

    A Small Business Innovative Research (SBIR) contract was recently awarded to a start up company for the development of an infrared (IR) image based combat casualty care system. The company, Medical Thermal Diagnostics, or MTD, is developing a light weight, hands free, energy efficient uncooled IR imaging system based upon a Texas Instruments design which will allow emergency medical treatment of wounded soldiers in complete darkness without any type of light enhancement equipment. The principal investigator for this effort, Dr. Gene Luther, DVM, Ph.D., Professor Emeritus, LSU School of Veterinary Medicine, will conduct the development and testing of this system with support from Thermalscan, Inc., a nondestructive testing company experienced in IR thermography applications. Initial research has been done with surgery on a cat for feasibility of the concept as well as forensic research on pigs as a close representation of human physiology to determine time of death. Further such studies will be done later as well as trauma studies. IR images of trauma injuries will be acquired by imaging emergency room patients to create an archive of emergency medical situations seen with an infrared imaging camera. This archived data will then be used to develop training material for medical personnel using the system. This system has potential beyond military applications. Firefighters and emergency medical technicians could directly benefit from the capability to triage and administer medical care to trauma victims in low or no light conditions.

  16. Bar coded retroreflective target

    DOEpatents

    Vann, Charles S.

    2000-01-01

    This small, inexpensive, non-contact laser sensor can detect the location of a retroreflective target in a relatively large volume and up to six degrees of position. The tracker's laser beam is formed into a plane of light which is swept across the space of interest. When the beam illuminates the retroreflector, some of the light returns to the tracker. The intensity, angle, and time of the return beam is measured to calculate the three dimensional location of the target. With three retroreflectors on the target, the locations of three points on the target are measured, enabling the calculation of all six degrees of target position. Until now, devices for three-dimensional tracking of objects in a large volume have been heavy, large, and very expensive. Because of the simplicity and unique characteristics of this tracker, it is capable of three-dimensional tracking of one to several objects in a large volume, yet it is compact, light-weight, and relatively inexpensive. Alternatively, a tracker produces a diverging laser beam which is directed towards a fixed position, and senses when a retroreflective target enters the fixed field of view. An optically bar coded target can be read by the tracker to provide information about the target. The target can be formed of a ball lens with a bar code on one end. As the target moves through the field, the ball lens causes the laser beam to scan across the bar code.

  17. Miniature Laser Tracker

    DOEpatents

    Vann, Charles S.

    2003-09-09

    This small, inexpensive, non-contact laser sensor can detect the location of a retroreflective target in a relatively large volume and up to six degrees of position. The tracker's laser beam is formed into a plane of light which is swept across the space of interest. When the beam illuminates the retroreflector, some of the light returns to the tracker. The intensity, angle, and time of the return beam is measured to calculate the three dimensional location of the target. With three retroreflectors on the target, the locations of three points on the target are measured, enabling the calculation of all six degrees of target position. Until now, devices for three-dimensional tracking of objects in a large volume have been heavy, large, and very expensive. Because of the simplicity and unique characteristics of this tracker, it is capable of three-dimensional tracking of one to several objects in a large volume, yet it is compact, light-weight, and relatively inexpensive. Alternatively, a tracker produces a diverging laser beam which is directed towards a fixed position, and senses when a retroreflective target enters the fixed field of view. An optically bar coded target can be read by the tracker to provide information about the target. The target can be formed of a ball lens with a bar code on one end. As the target moves through the field, the ball lens causes the laser beam to scan across the bar code.

  18. Effects of Bulk Composition on the Atmospheric Dynamics on Close-in Exoplanets

    NASA Astrophysics Data System (ADS)

    Zhang, Xi; Showman, Adam P.

    2017-02-01

    Super Earths and mini Neptunes likely have a wide range of atmospheric compositions, ranging from low molecular mass atmospheres of H2 to higher molecular atmospheres of water, CO2, N2, or other species. Here we systematically investigate the effects of atmospheric bulk compositions on temperature and wind distributions for tidally locked sub-Jupiter-sized planets, using an idealized 3D general circulation model (GCM). The bulk composition effects are characterized in the framework of two independent variables: molecular weight and molar heat capacity. The effect of molecular weight dominates. As the molecular weight increases, the atmosphere tends to have a larger day-night temperature contrast, a smaller eastward phase shift in the thermal phase curve, and a smaller zonal wind speed. The width of the equatorial super-rotating jet also becomes narrower, and the “jet core” region, where the zonal-mean jet speed maximizes, moves to a greater pressure level. The zonal-mean zonal wind is more prone to exhibit a latitudinally alternating pattern in a higher molecular weight atmosphere. We also present analytical theories that quantitatively explain the above trends and shed light on the underlying dynamical mechanisms. Those trends might be used to indirectly determine the atmospheric compositions on tidally locked sub-Jupiter-sized planets. The effects of the molar heat capacity are generally small. But if the vertical temperature profile is close to adiabatic, molar heat capacity will play a significant role in controlling the transition from a divergent flow in the upper atmosphere to a jet-dominated flow in the lower atmosphere.

  19. Effect of varying recording cable weight and flexibility on activity and sleep in mice.

    PubMed

    Tang, Xiangdong; Orchard, Stuart M; Liu, Xianling; Sanford, Larry D

    2004-06-15

    Sleep in mice has typically been determined from electroencephalograms and electromyograms recorded via cables in tethered animals. However, the relatively small physical size of mice can produce concerns in recording with cables that may not be seen in larger animals. To examine the influence of implantation and tethering on mice, we recorded activity and sleep in 2 strains while they were attached to 3 cable configurations that varied in weight and flexibility. Activity was recorded prior to surgery and after surgery without tethering. Afterward, the mice were habituated to 3 cable configurations (light [L]: 1.5 g; medium [M]: 2.2 g; heavy [H]: 3.0 g), and activity and sleep were recorded for 2 consecutive days under each configuration. N/A. Studies were conducted in 2 mouse strains that differ significantly in levels of spontaneous activity (more-active strain: BALB/cJ [C]; less-active strain: DBA/2J [D2]). N/A. Significant postsurgery reductions in activity in nontethered mice were found only in the more-active C strain. Activity in both strains was reduced in a graded manner as cable weight increased and flexibility decreased. In contrast, changes in sleep were not graded across cables, and changes in rapid eye movement sleep showed more variability. In addition, the effects of varying cables were not consistent across strains. The differential impact that variations in the weight and flexibility of recording cables can have on the amount and patterns of sleep is an important consideration in conducting and interpreting sleep studies in mice.

  20. 7 CFR 52.1847 - Colors of golden seedless raisins.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... raisins are practically uniform in color and may range from yellow or golden to light amber color with a... uniform in color and may range from yellow or golden or greenish yellow to light amber wherein the predominating color may be greenish yellow or light amber and that not more than 3 percent, by weight, of all...

  1. 7 CFR 52.1847 - Colors of golden seedless raisins.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... raisins are practically uniform in color and may range from yellow or golden to light amber color with a... uniform in color and may range from yellow or golden or greenish yellow to light amber wherein the predominating color may be greenish yellow or light amber and that not more than 3 percent, by weight, of all...

  2. Comparison of a reduced carbohydrate and reduced fat diet for LDL, HDL, and VLDL subclasses during 9-months of weight maintenance subsequent to weight loss.

    PubMed

    LeCheminant, James D; Smith, Bryan K; Westman, Eric C; Vernon, Mary C; Donnelly, Joseph E

    2010-06-01

    This study compared LDL, HDL, and VLDL subclasses in overweight or obese adults consuming either a reduced carbohydrate (RC) or reduced fat (RF) weight maintenance diet for 9 months following significant weight loss. Thirty-five (21 RC; 14 RF) overweight or obese middle-aged adults completed a 1-year weight management clinic. Participants met weekly for the first six months and bi-weekly thereafter. Meetings included instruction for diet, physical activity, and behavior change related to weight management. Additionally, participants followed a liquid very low-energy diet of approximately 2092 kJ per day for the first three months of the study. Subsequently, participants followed a dietary plan for nine months that targeted a reduced percentage of carbohydrate (approximately 20%) or fat (approximately 30%) intake and an energy intake level calculated to maintain weight loss. Lipid subclasses using NMR spectroscopy were analyzed prior to weight loss and at multiple intervals during weight maintenance. Body weight change was not significantly different within or between groups during weight maintenance (p>0.05). The RC group showed significant increases in mean LDL size, large LDL, total HDL, large and small HDL, mean VLDL size, and large VLDL during weight maintenance while the RF group showed increases in total HDL, large and small HDL, total VLDL, and large, medium, and small VLDL (p<0.05). Group*time interactions were significant for large and medium VLDL (p>0.05). Some individual lipid subclasses improved in both dietary groups. Large and medium VLDL subclasses increased to a greater extent across weight maintenance in the RF group.

  3. Light-weight analyzer for odor recognition

    DOEpatents

    Vass, Arpad A; Wise, Marcus B

    2014-05-20

    The invention provides a light weight analyzer, e.g., detector, capable of locating clandestine graves. The detector utilizes the very specific and unique chemicals identified in the database of human decompositional odor. This detector, based on specific chemical compounds found relevant to human decomposition, is the next step forward in clandestine grave detection and will take the guess-work out of current methods using canines and ground-penetrating radar, which have historically been unreliable. The detector is self contained, portable and built for field use. Both visual and auditory cues are provided to the operator.

  4. A Light-Weight Inflatable Hypersonic Drag Device for Planetary Entry

    NASA Technical Reports Server (NTRS)

    McRonald, Angus D.

    2000-01-01

    The author has analyzed the use of a light-weight inflatable hypersonic drag device, called a ballute, for flight in planetary atmospheres, for entry, aerocapture, and aerobraking. Studies to date include Mars, Venus, Earth, Saturn, Titan, Neptune and Pluto, and data on a Pluto lander and a Mars orbiter will be presented to illustrate the concept. The main advantage of using a ballute is that aero, deceleration and heating in atmospheric entry occurs at much smaller atmospheric density with a ballute than without it. For example, if a ballute has a diameter 10 times as large as the spacecraft, for unchanged total mass, entry speed and entry angle,the atmospheric density at peak convective heating is reduced by a factor of 100, reducing the heating by a factor of 10 for the spacecraft and a factor of 30 for the ballute. Consequently the entry payload (lander, orbiter, etc) is subject to much less heating, requires a much reduced thermal. protection system (possibly only an MLI blanket), and the spacecraft design is therefore relatively unchanged from its vacuum counterpart. The heat flux on the ballute is small enough to be radiated at temperatures below 800 K or so. Also, the heating may be reduced further because the ballute enters at a more shallow angle, even allowing for the increased delivery angle error. Added advantages are less mass ratio of entry system to total entry mass, and freedom from the low-density and transonic instability problems that conventional rigid entry bodies suffer, since the vehicle attitude is determined by the ballute, usually released at continuum conditions (hypersonic for an orbiter, and subsonic for a lander). Also, for a lander the range from entry to touchdown is less, offering a smaller footprint. The ballute derives an entry corridor for aerocapture by entering on a path that would lead to landing, and releasing the ballute adaptively, responding to measured deceleration, at a speed computed to achieve the desired orbiter exit conditions. For a lander an accurate landing point could be achieved by providing the lander with a small gliding capacity, using the large potential energy available from being subsonic at high altitude. Alternatively the ballute can be retained to act as a parachute or soft-landing device, or to float the payload as a buoyant aerobot. As expected, the ballute has smaller size for relatively small entry speeds, such as for Mars and Titan, or for the extensive atmosphere of a low-gravity planet such as Pluto. Details of a ballute to place a small Mars orbiter and a small Pluto lander will be given to illustrate the concept. The author will discuss presently available ballute materials and a development program of aerodynamic tests and materials that would be required for ballutes to achieve their full potential.

  5. Risk of adverse outcomes among infants of immigrant women according to birth-weight curves tailored to maternal world region of origin.

    PubMed

    Urquia, Marcelo L; Berger, Howard; Ray, Joel G

    2015-01-06

    Infants of immigrant women in Western nations generally have lower birth weights than infants of native-born women. Whether this difference is physiologic or pathological is unclear. We determined whether the use of birth-weight curves tailored to maternal world region of origin would discriminate adverse neonatal and obstetric outcomes more accurately than a single birth-weight curve based on infants of Canadian-born women. We performed a retrospective cohort study of in-hospital singleton live births (328,387 to immigrant women, 761,260 to nonimmigrant women) in Ontario between 2002 and 2012 using population health services data linked to the national immigration database. We classified infants as small for gestational age (<10th percentile) or large for gestational age (≥90th percentile) using both Canadian and world region-specific birth-weight curves and compared associations with adverse neonatal and obstetric outcomes. Compared with world region-specific birth-weight curves, the Canadian curve classified 20 431 (6.2%) additional newborns of immigrant women as small for gestational age, of whom 15,467 (75.7%) were of East or South Asian descent. The odds of neonatal death were lower among small-for-gestational-age infants of immigrant women than among those of nonimmigrant women based on the Canadian birth-weight curve (adjusted odds ratio [OR] 0.83, 95% confidence interval [CI] 0.72-0.95), but higher when small for gestational age was defined by the world region-specific curves (adjusted OR 1.24, 95% CI 1.08-1.42). Conversely, the odds of some adverse outcomes were lower among large-for-gestational-age infants of immigrant women than among those of nonimmigrant women based on world region-specific birth-weight curves, but were similar based on the Canadian curve. World region-specific birth-weight curves seemed to be more appropriate than a single Canadian population-based curve for assessing the risk of adverse neonatal and obstetric outcomes among small- and large-for-gestational-age infants born to immigrant women, especially those from the East and South Asian regions. © 2015 Canadian Medical Association or its licensors.

  6. The Impact of Accelerometers on Physical Activity and Weight Loss: A Systematic Review

    PubMed Central

    Goode, Adam P.; Hall, Katherine S.; Batch, Bryan C.; Huffman, Kim M.; Hastings, S. Nicole; Allen, Kelli D.; Shaw, Ryan J.; Kanach, Frances A.; McDuffie, Jennifer R.; Kosinski, Andrzej S.; Williams, John W.; Gierisch, Jennifer M.

    2016-01-01

    Background Regular physical activity is important for improving and maintaining health, but sedentary behavior is difficult to change. Providing objective, real-time feedback on physical activity with wearable motion-sensing technologies (activity monitors) may be a promising, scalable strategy to increase physical activity or decrease weight. Purpose We synthesized the literature on the use of wearable activity monitors for improving physical activity and weight-related outcomes and evaluated moderating factors that may have an impact on effectiveness. Methods We searched five databases from January 2000 to January 2015 for peer-reviewed, English-language randomized controlled trials among adults. Random-effects models were used to produce standardized mean differences (SMDs) for physical activity outcomes and mean differences (MDs) for weight outcomes. Heterogeneity was measured with I2. Results Fourteen trials (2,972 total participants) met eligibility criteria; accelerometers were used in all trials. Twelve trials examined accelerometer interventions for increasing physical activity. A small significant effect was found for increasing physical activity (SMD 0.26; 95% CI 0.04 to 0.49; I2=64.7%). Intervention duration was the only moderator found to significantly explain high heterogeneity for physical activity. Eleven trials examined effects of accelerometer interventions on weight. Pooled estimates showed a small significant effect for weight loss (MD −1.65 kg; 95% CI −3.03 to −0.28; I2=81%), and no moderators were significant. Conclusions Accelerometers demonstrated small positive effects on physical activity and weight loss. The small sample sizes with moderate to high heterogeneity in the current studies limit the conclusions that may be drawn. Future studies should focus on how best to integrate accelerometers with other strategies to increase physical activity and weight loss. PMID:27565168

  7. NASA-UVa light aerospace alloy and structures technology program

    NASA Technical Reports Server (NTRS)

    Gangloff, Richard P.; Haviland, John K.; Herakovich, Carl T.; Pilkey, Walter D.; Pindera, Marek-Jerzy; Scully, John R.; Stoner, Glenn E.; Swanson, Robert E.; Thornton, Earl A.; Wawner, Franklin E., Jr.

    1991-01-01

    The general objective of the NASA-UVa Light Aerospace Alloy and Structures Technology Program was to conduct research on the performance of next generation, light weight aerospace alloys, composites, and associated thermal gradient structures. The following research areas were actively investigated: (1) mechanical and environmental degradation mechanisms in advanced light metals and composites; (2) aerospace materials science; (3) mechanics of materials and composites for aerospace structures; and (4) thermal gradient structures.

  8. Influence of environmental temperature and light intensity on growth performance and blood physiological parameters of broilers grown to heavy weight

    USDA-ARS?s Scientific Manuscript database

    In a study of temperature and light intensity, 9 treatments consisted of 3 levels (Low=15.6, Moderate=21.1, High=26.7 °C) of temperatures and 3 levels (0.5, 3.0, 20 lx) of light intensities from d 8 to 56 d of age. Across all light levels at d 56, broilers subjected to high temperature significantly...

  9. 40 CFR 86.129-00 - Road load power, test weight, and inertia weight class determination.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 19 2013-07-01 2013-07-01 false Road load power, test weight, and... Light-Duty Trucks and New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.129-00 Road load... running loss testing. Paragraphs (e) and (f) of this section are applicable to vehicles from engine...

  10. 40 CFR 86.129-00 - Road load power, test weight, and inertia weight class determination.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Road load power, test weight, and... Light-Duty Trucks and New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.129-00 Road load... running loss testing. Paragraphs (e) and (f) of this section are applicable to vehicles from engine...

  11. 40 CFR 86.129-00 - Road load power, test weight, and inertia weight class determination.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Road load power, test weight, and... Light-Duty Trucks and New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.129-00 Road load... running loss testing. Paragraphs (e) and (f) of this section are applicable to vehicles from engine...

  12. 40 CFR 86.129-00 - Road load power, test weight, and inertia weight class determination.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Road load power, test weight, and... Light-Duty Trucks and New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.129-00 Road load... running loss testing. Paragraphs (e) and (f) of this section are applicable to vehicles from engine...

  13. 40 CFR 86.129-00 - Road load power, test weight, and inertia weight class determination.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Road load power, test weight, and... Light-Duty Trucks and New Otto-Cycle Complete Heavy-Duty Vehicles; Test Procedures § 86.129-00 Road load... running loss testing. Paragraphs (e) and (f) of this section are applicable to vehicles from engine...

  14. Design and modeling of an additive manufactured thin shell for x-ray astronomy

    NASA Astrophysics Data System (ADS)

    Feldman, Charlotte; Atkins, Carolyn; Brooks, David; Watson, Stephen; Cochrane, William; Roulet, Melanie; Willingale, Richard; Doel, Peter

    2017-09-01

    Future X-ray astronomy missions require light-weight thin shells to provide large collecting areas within the weight limits of launch vehicles, whilst still delivering angular resolutions close to that of Chandra (0.5 arc seconds). Additive manufacturing (AM), also known as 3D printing, is a well-established technology with the ability to construct or `print' intricate support structures, which can be both integral and light-weight, and is therefore a candidate technique for producing shells for space-based X-ray telescopes. The work described here is a feasibility study into this technology for precision X-ray optics for astronomy and has been sponsored by the UK Space Agency's National Space Technology Programme. The goal of the project is to use a series of test samples to trial different materials and processes with the aim of developing a viable path for the production of an X-ray reflecting prototype for astronomical applications. The initial design of an AM prototype X-ray shell is presented with ray-trace modelling and analysis of the X-ray performance. The polishing process may cause print-through from the light-weight support structure on to the reflecting surface. Investigations in to the effect of the print-through on the X-ray performance of the shell are also presented.

  15. Measurements of volatile compound contents in resins using a moisture analyzer.

    PubMed

    Hashimoto, Masanori; Nagano, Futami; Endo, Kazuhiko; Ohno, Hiroki

    2010-02-01

    The contents of volatile adhesive compounds, such as water, solvents, and residual unpolymerized monomers, affect the integrity and durability of adhesive bonding. However, there is no method available that can be used to rapidly assess the residual solvent or water contents of adhesive resins. This study examined the effectiveness of a digital moisture analyzer to measure the volatile compound contents of resins. Five self-etching adhesives and seven experimental light-cured resins prepared with different contents (0, 10, and 20% by weight) of water or solvents (acetone and ethanol) were examined in this study. The resins were prepared using different methods (with and without air blast or light-curing) to simulate the clinical conditions of adhesive application. Resin weight changes (% of weight loss) were determined as the residual volatile compound contents, using the moisture analyzer. After the measurements, the resin films were examined using a scanning electron microscope. The weight changes of the resins were found to depend on the amount of water or solvents evaporating from the resin. Water and solvents were evaporated by air blast or light-curing, but some of the water and solvents remained in the cured resin. The moisture analyzer is easy to operate and is a useful instrument for using to measure the residual volatile compound contents of adhesive resin.

  16. Miniature photometric stereo system for textile surface structure reconstruction

    NASA Astrophysics Data System (ADS)

    Gorpas, Dimitris; Kampouris, Christos; Malassiotis, Sotiris

    2013-04-01

    In this work a miniature photometric stereo system is presented, targeting the three-dimensional structural reconstruction of various fabric types. This is a supportive module to a robot system, attempting to solve the well known "laundry problem". The miniature device has been designed for mounting onto the robot gripper. It is composed of a low-cost off-the-shelf camera, operating in macro mode, and eight light emitting diodes. The synchronization between image acquisition and lighting direction is controlled by an Arduino Nano board and software triggering. The ambient light has been addressed by a cylindrical enclosure. The direction of illumination is recovered by locating the reflection or the brightest point on a mirror sphere, while a flatfielding process compensates for the non-uniform illumination. For the evaluation of this prototype, the classical photometric stereo methodology has been used. The preliminary results on a large number of textiles are very promising for the successful integration of the miniature module to the robot system. The required interaction with the robot is implemented through the estimation of the Brenner's focus measure. This metric successfully assesses the focus quality with reduced time requirements in comparison to other well accepted focus metrics. Besides the targeting application, the small size of the developed system makes it a very promising candidate for applications with space restrictions, like the quality control in industrial production lines or object recognition based on structural information and in applications where easiness in operation and light-weight are required, like those in the Biomedical field, and especially in dermatology.

  17. Overwintering temperature and body condition shift emergence dates of spring-emerging solitary bees.

    PubMed

    Schenk, Mariela; Mitesser, Oliver; Hovestadt, Thomas; Holzschuh, Andrea

    2018-01-01

    Solitary bees in seasonal environments must align their life-cycles with favorable environmental conditions and resources; the timing of their emergence is highly fitness relevant. In several bee species, overwintering temperature influences both emergence date and body weight at emergence. High variability in emergence dates among specimens overwintering at the same temperatures suggests that the timing of emergence also depends on individual body conditions. However, possible causes for this variability, such as individual differences in body size or weight, have been rarely studied. In a climate chamber experiment using two spring-emerging mason bees ( Osmia cornuta and O. bicornis ), we investigated the relationship between temperature, emergence date, body weight, and body size, the last of which is not affected by overwintering temperature. Our study showed that body weight declined during hibernation more strongly in warm than in cold overwintering temperatures. Although bees emerged earlier in warm than in cold overwintering temperatures, at the time of emergence, bees in warm overwintering temperatures had lower body weights than bees in cold overwintering temperatures (exception of male O. cornuta ). Among specimens that experienced the same overwintering temperatures, small and light bees emerged later than their larger and heavier conspecifics. Using a simple mechanistic model we demonstrated that spring-emerging solitary bees use a strategic approach and emerge at a date that is most promising for their individual fitness expectations. Our results suggest that warmer overwintering temperatures reduce bee fitness by causing a decrease in body weight at emergence. We showed furthermore that in order to adjust their emergence dates, bees use not only temperature but also their individual body condition as triggers. This may explain differing responses to climate warming within and among bee populations and may have consequences for bee-plant interactions as well as for the persistence of bee populations under climate change.

  18. A comparative study of the costliness of Manitoba hospitals.

    PubMed

    Shanahan, M; Loyd, M; Roos, N P; Brownell, M

    1999-06-01

    In light of ongoing discussions about health care policy, this study offered a method of calculating costs at Manitoba hospitals that compared relative costliness of inpatient care provided in each hospital. This methodology also allowed comparisons across types of hospitals-teaching, community, major rural, intermediate and small rural, as well as northern isolated facilities. Data used in this project include basic hospital information, both financial and statistical, for each of the Manitoba hospitals, hospital charge information by case from the State of Maryland, and hospital discharge abstract information for Manitoba. The data from Maryland were used to create relative cost weights (RCWs) for refined diagnostic related groups (RDRGs) and were subsequently adjusted for Manitoba length of stay. These case weights were then applied to cases in Manitoba hospitals, and several other adjustments were made for nontypical cases. This case mix system allows cost comparisons across hospitals. In general, hospital case mix costing demonstrated variability in hospital costliness, not only across types of hospitals but also within hospitals of the same type and size. Costs at the teaching hospitals were found to be considerably higher than the average, even after accounting for acuity and case mix.

  19. Optimizing LED lighting for space plant growth unit: Joint effects of photon flux density, red to white ratios and intermittent light pulses.

    PubMed

    Avercheva, O V; Berkovich, Yu A; Konovalova, I O; Radchenko, S G; Lapach, S N; Bassarskaya, E M; Kochetova, G V; Zhigalova, T V; Yakovleva, O S; Tarakanov, I G

    2016-11-01

    The aim of this work were to choose a quantitative optimality criterion for estimating the quality of plant LED lighting regimes inside space greenhouses and to construct regression models of crop productivity and the optimality criterion depending on the level of photosynthetic photon flux density (PPFD), the proportion of the red component in the light spectrum and the duration of the duty cycle (Chinese cabbage Brassica сhinensis L. as an example). The properties of the obtained models were described in the context of predicting crop dry weight and the optimality criterion behavior when varying plant lighting parameters. Results of the fractional 3-factor experiment demonstrated the share of the PPFD level participation in the crop dry weight accumulation was 84.4% at almost any combination of other lighting parameters, but when PPFD value increased up to 500µmol m -2 s -1 the pulse light and supplemental light from red LEDs could additionally increase crop productivity. Analysis of the optimality criterion response to variation of lighting parameters showed that the maximum coordinates were the following: PPFD = 500µmol m -2 s -1 , about 70%-proportion of the red component of the light spectrum (PPFD LEDred /PPFD LEDwhite = 1.5) and the duty cycle with a period of 501µs. Thus, LED crop lighting with these parameters was optimal for achieving high crop productivity and for efficient use of energy in the given range of lighting parameter values. Copyright © 2016 The Committee on Space Research (COSPAR). Published by Elsevier Ltd. All rights reserved.

  20. Global sustainability and key needs in future automotive design.

    PubMed

    McAuley, John W

    2003-12-01

    The number of light vehicle registrations is forecast to increase worldwide by a factor of 3-5 over the next 50 years. This will dramatically increase environmental impacts worldwide of automobiles and light trucks. If light vehicles are to be environmentally sustainable globally, the automotive industry must implement fundamental changes in future automotive design. Important factors in assessing automobile design needs include fuel economy and reduced emissions. Many design parameters can impact vehicle air emissions and energy consumption including alternative fuel or engine technologies, rolling resistance, aerodynamics, drive train design, friction, and vehicle weight. Of these, vehicle weight is key and will translate into reduced energy demand across all energy distribution elements. A new class of vehicles is needed that combines ultra-light design with a likely hybrid or fuel cell engine technology. This could increase efficiency by a factor of 3-5 and reduce air emissions as well. Advanced lightweight materials, such as plastics or composites, will need to overtake the present metal-based infrastructure. Incorporating design features to facilitate end-of-life recycling and recovery is also important. The trend will be towards fewer materials and parts in vehicle design, combined with ease of disassembly. Mono-material construction can create vehicle design with improved recyclability as well as reduced numbers of parts and weight.

  1. A method to estimate weight and dimensions of large and small gas turbine engines

    NASA Technical Reports Server (NTRS)

    Onat, E.; Klees, G. W.

    1979-01-01

    A computerized method was developed to estimate weight and envelope dimensions of large and small gas turbine engines within + or - 5% to 10%. The method is based on correlations of component weight and design features of 29 data base engines. Rotating components were estimated by a preliminary design procedure which is sensitive to blade geometry, operating conditions, material properties, shaft speed, hub tip ratio, etc. The development and justification of the method selected, and the various methods of analysis are discussed.

  2. Adaptive slab laser beam quality improvement using a weighted least-squares reconstruction algorithm.

    PubMed

    Chen, Shanqiu; Dong, LiZhi; Chen, XiaoJun; Tan, Yi; Liu, Wenjin; Wang, Shuai; Yang, Ping; Xu, Bing; Ye, YuTang

    2016-04-10

    Adaptive optics is an important technology for improving beam quality in solid-state slab lasers. However, there are uncorrectable aberrations in partial areas of the beam. In the criterion of the conventional least-squares reconstruction method, it makes the zones with small aberrations nonsensitive and hinders this zone from being further corrected. In this paper, a weighted least-squares reconstruction method is proposed to improve the relative sensitivity of zones with small aberrations and to further improve beam quality. Relatively small weights are applied to the zones with large residual aberrations. Comparisons of results show that peak intensity in the far field improved from 1242 analog digital units (ADU) to 2248 ADU, and beam quality β improved from 2.5 to 2.0. This indicates the weighted least-squares method has better performance than the least-squares reconstruction method when there are large zonal uncorrectable aberrations in the slab laser system.

  3. Effect of intensity and program delivery on the translation of DPP to worksites: A randomized controlled trial of Fuel Your Life

    PubMed Central

    DeJoy, David M.; Vandenberg, Robert J.; Corso, Phaedra; Padilla, Heather; Zuercher, Heather

    2016-01-01

    Objective To evaluate the effectiveness of the Fuel Your Life program, an adaptation of the Diabetes Prevention Program, utilizing implementation strategies commonly used in worksite programs – telephone coaching, small group coaching and self-study. Methods The primary outcomes of BMI and weight were examined in a randomized control trial conducted with city/county employees. Results Although the majority of participants in all three groups lost some weight, the phone group lost significantly more weight (4.9 lbs.), followed by the small groups (3.4 lbs.) and the self-study (2.7 lbs.). Of the total participants, 28.3% of the phone group, 20.6% of the small group and 15.7 of the self-study group lost 5% or more of their body weight. Conclusions Fuel Your Life (DPP) can be effectively disseminated using different implementation strategies that are tailored to the workplace. PMID:27820761

  4. Auditory brainstem response in neonates: influence of gender and weight/gestational age ratio

    PubMed Central

    Angrisani, Rosanna M. Giaffredo; Bautzer, Ana Paula D.; Matas, Carla Gentile; de Azevedo, Marisa Frasson

    2013-01-01

    OBJECTIVE: To investigate the influence of gender and weight/gestational age ratio on the Auditory Brainstem Response (ABR) in preterm (PT) and term (T) newborns. METHODS: 176 newborns were evaluated by ABR; 88 were preterm infants - 44 females (22 small and 22 appropriate for gestational age) and 44 males (22 small and 22 appropriate for gestational age). The preterm infants were compared to 88 term infants - 44 females (22 small and 22 appropriate for gestational age) and 44 males (22 small and 22 appropriate for gestational age). All newborns had bilateral presence of transient otoacoustic emissions and type A tympanometry. RESULTS: No interaural differences were found. ABR response did not differentiate newborns regarding weight/gestational age in males and females. Term newborn females showed statistically shorter absolute latencies (except on wave I) than males. This finding did not occur in preterm infants, who had longer latencies than term newborns, regardless of gender. CONCLUSIONS: Gender and gestational age influence term infants' ABR, with lower responses in females. The weight/gestational age ratio did not influence ABR response in either groups. PMID:24473955

  5. Fibre Optic Sensors for Structural Health Monitoring of Aircraft Composite Structures: Recent Advances and Applications

    PubMed Central

    Di Sante, Raffaella

    2015-01-01

    In-service structural health monitoring of composite aircraft structures plays a key role in the assessment of their performance and integrity. In recent years, Fibre Optic Sensors (FOS) have proved to be a potentially excellent technique for real-time in-situ monitoring of these structures due to their numerous advantages, such as immunity to electromagnetic interference, small size, light weight, durability, and high bandwidth, which allows a great number of sensors to operate in the same system, and the possibility to be integrated within the material. However, more effort is still needed to bring the technology to a fully mature readiness level. In this paper, recent research and applications in structural health monitoring of composite aircraft structures using FOS have been critically reviewed, considering both the multi-point and distributed sensing techniques. PMID:26263987

  6. Civil infrastructure monitoring for IVHS using optical fiber sensors

    NASA Astrophysics Data System (ADS)

    de Vries, Marten J.; Arya, Vivek; Grinder, C. R.; Murphy, Kent A.; Claus, Richard O.

    1995-01-01

    8Early deployment of Intelligent Vehicle Highway Systems would necessitate the internal instrumentation of infrastructure for emergency preparedness. Existing quantitative analysis and visual analysis techniques are time consuming, cost prohibitive, and are often unreliable. Fiber optic sensors are rapidly replacing conventional instrumentation because of their small size, light weight, immunity to electromagnetic interference, and extremely high information carrying capability. In this paper research on novel optical fiber sensing techniques for health monitoring of civil infrastructure such as highways and bridges is reported. Design, fabrication, and implementation of fiber optic sensor configurations used for measurements of strain are discussed. Results from field tests conducted to demonstrate the effectiveness of fiber sensors at determining quantitative strain vector components near crack locations in bridges are presented. Emerging applications of fiber sensors for vehicle flow, vehicle speed, and weigh-in-motion measurements are also discussed.

  7. Venturi vacuum systems for hypobaric chamber operations.

    PubMed

    Robinson, R; Swaby, G; Sutton, T; Fife, C; Powell, M; Butler, B D

    1997-11-01

    Physiological studies of the effects of high altitude on man often require the use of a hypobaric chamber to simulate the reduced ambient pressures. Typical "altitude" chambers in use today require complex mechanical vacuum systems to evacuate the chamber air, either directly or via reservoir system. Use of these pumps adds to the cost of both chamber procurement and maintenance, and service of these pumps requires trained support personnel and regular upkeep. In this report we describe use of venturi vacuum pumps to perform the function of mechanical vacuum pumps for human and experimental altitude chamber operations. Advantages of the venturi pumps include their relatively low procurement cost, small size and light weight, ease of installation and plumbing, lack of moving parts, and independence from electrical power sources, fossil fuels and lubricants. Conversion of three hyperbaric chambers to combined hyper/hypobaric use is described.

  8. Theoretical evaluation of scattering effect on retroreflective free-space optical communication.

    PubMed

    Yin, Hongwei; Lan, Tianpeng; Zhang, Hailiang; Jia, Honghui; Chang, Shengli; Yang, Juncai

    2012-12-01

    Retroreflective free-space optical (RFSO) communication is a new concept of optical communication; it consists of an optical transceiver and a retromodulator and has advantages such as light weight, small volume, and low power consumption. The power captured by the receiver consists of two parts: retroreflective and scattering. The retroreflective characteristics are obtained using an analytical formula, the scattering characteristics using a Monte Carlo model. Results show that the scattering power plays an important role in a RFSO communication link, especially when the communication range is long or the meteorological range is short. Some rules are also obtained for the sake of system design, which include increasing the range from the transmitter and the receiver properly, increasing the area of the retromodulator, limiting the field of view of the receiver, and limiting the beam divergence of the transmitter.

  9. Dilatometer setup for low coefficient of thermal expansion materials measurements in the 140 K-250 K temperature range.

    PubMed

    Spannagel, Ruven; Hamann, Ines; Sanjuan, Josep; Schuldt, Thilo; Gohlke, Martin; Johann, Ulrich; Weise, Dennis; Braxmaier, Claus

    2016-10-01

    Space applications demand light weight materials with excellent dimensional stability for telescopes, optical benches, optical resonators, etc. Glass-ceramics and composite materials can be tuned to reach very low coefficient of thermal expansion (CTE) at different temperatures. In order to determine such CTEs, very accurate setups are needed. Here we present a dilatometer that is able to measure the CTE of a large variety of materials in the temperature range of 140 K to 250 K. The dilatometer is based on a heterodyne interferometer with nanometer noise levels to measure the expansion of a sample when applying small amplitude controlled temperature signals. In this article, the CTE of a carbon fiber reinforced polymer sample has been determined with an accuracy in the 10 -8 K -1 range.

  10. Fibre Optic Sensors for Structural Health Monitoring of Aircraft Composite Structures: Recent Advances and Applications.

    PubMed

    Di Sante, Raffaella

    2015-07-30

    In-service structural health monitoring of composite aircraft structures plays a key role in the assessment of their performance and integrity. In recent years, Fibre Optic Sensors (FOS) have proved to be a potentially excellent technique for real-time in-situ monitoring of these structures due to their numerous advantages, such as immunity to electromagnetic interference, small size, light weight, durability, and high bandwidth, which allows a great number of sensors to operate in the same system, and the possibility to be integrated within the material. However, more effort is still needed to bring the technology to a fully mature readiness level. In this paper, recent research and applications in structural health monitoring of composite aircraft structures using FOS have been critically reviewed, considering both the multi-point and distributed sensing techniques.

  11. Structural Health Monitoring of Civil Infrastructure Using Optical Fiber Sensing Technology: A Comprehensive Review

    PubMed Central

    Ye, X. W.; Su, Y. H.; Han, J. P.

    2014-01-01

    In the last two decades, a significant number of innovative sensing systems based on optical fiber sensors have been exploited in the engineering community due to their inherent distinctive advantages such as small size, light weight, immunity to electromagnetic interference (EMI) and corrosion, and embedding capability. A lot of optical fiber sensor-based monitoring systems have been developed for continuous measurement and real-time assessment of diversified engineering structures such as bridges, buildings, tunnels, pipelines, wind turbines, railway infrastructure, and geotechnical structures. The purpose of this review article is devoted to presenting a summary of the basic principles of various optical fiber sensors, innovation in sensing and computational methodologies, development of novel optical fiber sensors, and the practical application status of the optical fiber sensing technology in structural health monitoring (SHM) of civil infrastructure. PMID:25133250

  12. Structural health monitoring of civil infrastructure using optical fiber sensing technology: a comprehensive review.

    PubMed

    Ye, X W; Su, Y H; Han, J P

    2014-01-01

    In the last two decades, a significant number of innovative sensing systems based on optical fiber sensors have been exploited in the engineering community due to their inherent distinctive advantages such as small size, light weight, immunity to electromagnetic interference (EMI) and corrosion, and embedding capability. A lot of optical fiber sensor-based monitoring systems have been developed for continuous measurement and real-time assessment of diversified engineering structures such as bridges, buildings, tunnels, pipelines, wind turbines, railway infrastructure, and geotechnical structures. The purpose of this review article is devoted to presenting a summary of the basic principles of various optical fiber sensors, innovation in sensing and computational methodologies, development of novel optical fiber sensors, and the practical application status of the optical fiber sensing technology in structural health monitoring (SHM) of civil infrastructure.

  13. Optical data transmission technology for fixed and drag-on STS payloads umbilicals. Volume 1: Executive summary

    NASA Technical Reports Server (NTRS)

    St.denis, R. W.

    1981-01-01

    The feasibility of using optical data handling methods to transmit payload checkout and telemetry is discussed. Optical communications are superior to conventional communication systems for the following reasons: high data capacity optical channels; small and light weight optical cables; and optical signal immunity to electromagnetic interference. Task number one analyzed the ground checkout data requirements that may be expected from the payload community. Task number two selected the optical approach based on the interface requirements, the location of the interface, the amount of time required to reconfigure hardware, and the method of transporting the optical signal. Task number three surveyed and selected optical components for the two payload data link. Task number four makes a qualitative comparison of the conventional electrical communication system and the proposed optical communication system.

  14. Composites in energy generation and storage systems - An overview

    NASA Astrophysics Data System (ADS)

    Fulmer, R. W.

    Applications of glass-fiber reinforced composites (GER) in renewable and high-efficiency energy systems which are being developed to replace interim, long-term unacceptable energy sources such as foreign oil are reviewed. GFR are noted to have design flexibility, high strength, and low cost, as well as featuring a choice of fiber orientation and type of reinforcement. Blades, hub covers, nacelles, and towers for large and small WECS are being fabricated and tested and are displaying satisfactory strength, resistance to corrosion and catastrophic failure, impact tolerance, and light weight. Promising results have also been shown in the use of GFR as flywheel material for kinetic energy storage in conjunction with solar and wind electric systems, in electric cars, and as load levellers. Other applications are for heliostats, geothermal power plant pipes, dam-atoll tidal wave energy systems, and intake pipes for OTECs.

  15. Elimination of the light shift in rubidium gas cell frequency standards using pulsed optical pumping

    NASA Technical Reports Server (NTRS)

    English, T. C.; Jechart, E.; Kwon, T. M.

    1978-01-01

    Changes in the intensity of the light source in an optically pumped, rubidium, gas cell frequency standard can produce corresponding frequency shifts, with possible adverse effects on the long-term frequency stability. A pulsed optical pumping apparatus was constructed with the intent of investigating the frequency stability in the absence of light shifts. Contrary to original expectations, a small residual frequency shift due to changes in light intensity was experimentally observed. Evidence is given which indicates that this is not a true light-shift effect. Preliminary measurements of the frequency stability of this apparatus, with this small residual pseudo light shift present, are presented. It is shown that this pseudo light shift can be eliminated by using a more homogeneous C-field. This is consistent with the idea that the pseudo light shift is due to inhomogeneity in the physics package (position-shift effect).

  16. Maternal anthropometrics are associated with fetal size in different periods of pregnancy and at birth. The Generation R Study.

    PubMed

    Ay, L; Kruithof, C J; Bakker, R; Steegers, E A P; Witteman, J C M; Moll, H A; Hofman, A; Mackenbach, J P; Hokken-Koelega, A C S; Jaddoe, V W V

    2009-06-01

    We aimed to examine the associations of maternal anthropometrics with fetal weight measured in different periods of pregnancy and with birth outcomes. Population-based birth cohort study. Data of pregnant women and their children in Rotterdam, the Netherlands. In 8541 mothers, height, prepregnancy body mass index (BMI) and gestational weight gain were available. Fetal growth was measured by ultrasound in mid- and late pregnancy. Regression analyses were used to assess the impact of maternal anthropometrics on fetal weight and birth outcomes. Fetal weight and birth outcomes: weight (grams) and the risks of small (<5th percentile) and large (>95th percentile) size for gestational age at birth. Maternal BMI in pregnancy was positively associated with estimated fetal weight during pregnancy. The effect estimates increased with advancing gestational age. All maternal anthropometrics were positively associated with fetal size (P-values for trend <0.01). Mothers with both their prepregnancy BMI and gestational weight gain quartile in the lowest and highest quartiles showed the highest risks of having a small and large size for gestational age child at birth, respectively. The effect of prepregnancy BMI was strongly modified by gestational weight gain. Fetal growth is positively affected by maternal BMI during pregnancy. Maternal height, prepregnancy BMI and gestational weight gain are all associated with increased risks of small and large size for gestational age at birth in the offspring, with an increased effect when combined.

  17. Supplemental Upward Lighting from Underneath to Obtain Higher Marketable Lettuce (Lactuca sativa) Leaf Fresh Weight by Retarding Senescence of Outer Leaves

    PubMed Central

    Zhang, Geng; Shen, Shanqi; Takagaki, Michiko; Kozai, Toyoki; Yamori, Wataru

    2015-01-01

    Recently, the so-called “plant factory with artificial lighting” (PFAL) approach has been developed to provide safe and steady food production. Although PFALs can produce high-yielding and high-quality plants, the high plant density in these systems accelerates leaf senescence in the bottom (or outer) leaves owing to shading by the upper (or inner) leaves and by neighboring plants. This decreases yield and increases labor costs for trimming. Thus, the establishment of cultivation methods to retard senescence of outer leaves is an important research goal to improve PFAL yield and profitability. In the present study, we developed an LED lighting apparatus that would optimize light conditions for PFAL cultivation of a leafy vegetable. Lettuce (Lactuca sativa L.) was hydroponically grown under white, red, or blue LEDs, with light provided from above (downward), with or without supplemental upward lighting from underneath the plant. White LEDs proved more appropriate for lettuce growth than red or blue LEDs, and the supplemental lighting retarded the senescence of outer leaves and decreased waste (i.e., dead or low-quality senescent leaves), leading to an improvement of the marketable leaf fresh weight. PMID:26697055

  18. Muon reconstruction in the Daya Bay water pools

    DOE PAGES

    Hackenburg, R. W.

    2017-08-12

    Muon reconstruction in the Daya Bay water pools would serve to verify the simulated muon fluxes and offer the possibility of studying cosmic muons in general. This reconstruction is, however, complicated by many optical obstacles and the small coverage of photomultiplier tubes (PMTs) as compared to other large water Cherenkov detectors. The PMTs’ timing information is useful only in the case of direct, unreflected Cherenkov light. This requires PMTs to be added and removed as an hypothesized muon trajectory is iteratively improved, to account for the changing effects of obstacles and direction of light. Therefore, muon reconstruction in the Dayamore » Bay water pools does not lend itself to a general fitting procedure employing smoothly varying functions with continuous derivatives. Here, we describe an algorithm which overcomes these complications. It employs the method of Least Mean Squares to determine an hypothesized trajectory from the PMTs’ charge-weighted positions. This initially hypothesized trajectory is then iteratively refined using the PMTs’ timing information. Reconstructions with simulated data reproduce the simulated trajectory to within about 5° in direction and about 45 cm in position at the pool surface, with a bias that tends to pull tracks away from the vertical by about 3°.« less

  19. Using the ISS as a testbed to prepare for the next generation of space-based telescopes

    NASA Astrophysics Data System (ADS)

    Postman, Marc; Sparks, William B.; Liu, Fengchuan; Ess, Kim; Green, Joseph; Carpenter, Kenneth G.; Thronson, Harley; Goullioud, Renaud

    2012-09-01

    The infrastructure available on the ISS provides a unique opportunity to develop the technologies necessary to assemble large space telescopes. Assembling telescopes in space is a game-changing approach to space astronomy. Using the ISS as a testbed enables a concentration of resources on reducing the technical risks associated with integrating the technologies, such as laser metrology and wavefront sensing and control (WFS&C), with the robotic assembly of major components including very light-weight primary and secondary mirrors and the alignment of the optical elements to a diffraction-limited optical system in space. The capability to assemble the optical system and remove and replace components via the existing ISS robotic systems such as the Special Purpose Dexterous Manipulator (SPDM), or by the ISS Flight Crew, allows for future experimentation as well as repair if necessary. In 2015, first light will be obtained by the Optical Testbed and Integration on ISS eXperiment (OpTIIX), a small 1.5-meter optical telescope assembled on the ISS. The primary objectives of OpTIIX include demonstrating telescope assembly technologies and end-to-end optical system technologies that will advance future large optical telescopes.

  20. Investigation of global and local network properties of music perception with culturally different styles of music.

    PubMed

    Li, Yan; Rui, Xue; Li, Shuyu; Pu, Fang

    2014-11-01

    Graph theoretical analysis has recently become a popular research tool in neuroscience, however, there have been very few studies on brain responses to music perception, especially when culturally different styles of music are involved. Electroencephalograms were recorded from ten subjects listening to Chinese traditional music, light music and western classical music. For event-related potentials, phase coherence was calculated in the alpha band and then constructed into correlation matrices. Clustering coefficients and characteristic path lengths were evaluated for global properties, while clustering coefficients and efficiency were assessed for local network properties. Perception of light music and western classical music manifested small-world network properties, especially with a relatively low proportion of weights of correlation matrices. For local analysis, efficiency was more discernible than clustering coefficient. Nevertheless, there was no significant discrimination between Chinese traditional and western classical music perception. Perception of different styles of music introduces different network properties, both globally and locally. Research into both global and local network properties has been carried out in other areas; however, this is a preliminary investigation aimed at suggesting a possible new approach to brain network properties in music perception. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Vibration and shape control of hinged light structures using electromagnetic forces

    NASA Astrophysics Data System (ADS)

    Matsuzaki, Yuji; Miyachi, Shigenobu; Sasaki, Toshiyuki

    2003-08-01

    This paper describes a new electromagnetic device for vibration control of a light-weighted deployable/retractable structure which consists of many small units connected with mechanical hinges. A typical example of such a structure is a solar cell paddle of an artificial satellite which is composed of many thin flexible blankets connected in series. Vibration and shape control of the paddle is not easy, because control force and energy do not transmit well between the blankets which are discretely connected by hinges with each other. The new device consists of a permanent magnet glued along an edge of a blanket and an electric current-conducting coil glued along an adjoining edge of another adjacent blanket. Conduction of the electric current in a magnetic field from the magnet generates an electromagnetic force on the coil. By changing the current in the coil, therefore, we may control the vibration and shape of the blankets. To confirm the effectiveness of the new device, constructing a simple paddle model consisting eight hinge- panels, we have carried out a model experiment of vibration and shape control of the paddle. In addition, a numerical simulation of vibration control of the hinge structure is performed to compare with measured data.

  2. Muon reconstruction in the Daya Bay water pools

    NASA Astrophysics Data System (ADS)

    Hackenburg, R. W.

    2017-11-01

    Muon reconstruction in the Daya Bay water pools would serve to verify the simulated muon fluxes and offer the possibility of studying cosmic muons in general. This reconstruction is, however, complicated by many optical obstacles and the small coverage of photomultiplier tubes (PMTs) as compared to other large water Cherenkov detectors. The PMTs' timing information is useful only in the case of direct, unreflected Cherenkov light. This requires PMTs to be added and removed as an hypothesized muon trajectory is iteratively improved, to account for the changing effects of obstacles and direction of light. Therefore, muon reconstruction in the Daya Bay water pools does not lend itself to a general fitting procedure employing smoothly varying functions with continuous derivatives. Here, an algorithm is described which overcomes these complications. It employs the method of Least Mean Squares to determine an hypothesized trajectory from the PMTs' charge-weighted positions. This initially hypothesized trajectory is then iteratively refined using the PMTs' timing information. Reconstructions with simulated data reproduce the simulated trajectory to within about 5°in direction and about 45 cm in position at the pool surface, with a bias that tends to pull tracks away from the vertical by about 3°.

  3. Optical Scattering Characterization for the Glennan Microsystems Microscale Particulate Classifier

    NASA Technical Reports Server (NTRS)

    Lock, James A.

    2002-01-01

    Small sensors that are tolerant to mechanically and thermally harsh environments present the possibility for in-situ particle characterization in propulsion, industrial, and planetary science applications. Under a continuing grant from the Glennan Microsystems Initiative to the Microgravity Fluids Physics Branch of the NASA-Glenn Research Center, a Microscale Particle Classifier (MiPAC) instrument is being developed. The MiPAC instrument will be capable of determining the size distribution of airborne particles from about 1 nm to 30 micrometers, and will provide partial information as to the concentration, charge state, shape, and structure of the particles, while being an order of magnitude smaller in size and lighter in weight than presently commercially available instruments. The portion of the instrument that will characterize the nm-range particles will employ electrical mobility techniques and is being developed under a separate grant to Prof. David Pui of the University of Minnesota. The portion of the instrument that will characterize the micrometer-size particles such as dirt, pollens, spores, molds, soot, and combustion aerosols will use light scattering techniques. The development of data analysis techniques to be employed in the light scattering portion of the instrument is covered by this grant.

  4. ZnO-PVA nanocomposite films for low threshold optical limiting applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Viswanath, Varsha; Beenakumari, C.; Muneera, C. I.

    Zinc oxide-PVA nanocomposite films were fabricated adopting a simple method based on solution-casting, incorporating small weight percentages (<1.2 wt%) of ZnO in PVA (∼0.625×10{sup −3}M to 7×10{sup −3}M), and their structure, morphology, linear and low threshold nonlinear optical properties were investigated. The films were characterized as nanostructured ZnO encapsulated between the molecules/chains of the semicrystalline host polymer PVA. The samples exhibited low threshold nonlinear absorption and negative nonlinear refraction, as studied using the Z-scan technique. A switchover from SA to RSA was observed as the concentration of ZnO was increased. The optical limiting of 632.8 nm CW laser light displayedmore » by these nanocomposite films is also demonstrated. The estimated values of the effective coefficients of nonlinear absorption, nonlinear refraction and third-order nonlinear susceptibility, |χ{sup (3)}|, compared to those reported for continuous wave laser light excitation, measure up to the highest among them. The results show that the ZnO-PVA nanocomposite films have great potential applications in future optical and photonic devices.« less

  5. Dynamics of an SAITS alcoholism model on unweighted and weighted networks

    NASA Astrophysics Data System (ADS)

    Huo, Hai-Feng; Cui, Fang-Fang; Xiang, Hong

    2018-04-01

    A novel SAITS alcoholism model on networks is introduced, in which alcoholics are divided into light problem alcoholics and heavy problem alcoholics. Susceptible individuals can enter into the compartment of heavy problem alcoholics directly by contacting with light problem alcoholics or heavy problem alcoholics and the heavy problem alcoholics who receive treatment can relapse into the compartment of heavy problem alcoholics are also considered. First, the dynamics of our model on unweighted networks, including the basic reproduction number, existence and stability of equilibria are studied. Second, the models with fixed weighted and adaptive weighted networks are introduced and investigated. At last, some simulations are presented to illustrate and extend our results. Our results show that it is very important to treat alcoholics to quit the drinking.

  6. Low birth weight and school readiness.

    PubMed

    Reichman, Nancy E

    2005-01-01

    In the United States black women have for decades been twice as likely as white women to give birth to babies of low birth weight who are at elevated risk for developmental disabilities. Does the black-white disparity in low birth weight contribute to the racial disparity in readiness? The author summarizes the cognitive and behavioral problems that beset many low birth weight children and notes that not only are the problems greatest for the smallest babies, but black babies are two to three times as likely as whites to be very small. Nevertheless, the racial disparities in low birth weight cannot explain much of the aggregate gap in readiness because the most serious birth weight-related disabilities affect a very small share of children. The author estimates that low birth weight explains at most 3-4 percent of the racial gap in IQ scores. The author applauds the post-1980 expansions of Medicaid for increasing rates of prenatal care use among poor pregnant women but stresses that standard prenatal medical care cannot improve aggregate birth outcomes substantially. Smoking cessation and nutrition are two prenatal interventions that show promise. Several early intervention programs have been shown to improve cognitive skills of low birth weight children. But even the most promising programs can narrow the readiness gap only a little because their benefits are greatest for heavier low birth weight children and because low birth weight explains only a small share of the gap. The author stresses the importance of reducing rates of low birth weight generally and of extending to all children who need them the interventions that have improved cognitive outcomes among low birth weight children. But because black infants are more likely to be born at the lowest birth weights, preventing low birth weight--when researchers learn how to--is likely to be more effective than early intervention in narrowing birth weight-related racial gaps in school readiness.

  7. Influence of ultraviolet light irradiation on the corrosion behavior of carbon steel AISI 1015

    NASA Astrophysics Data System (ADS)

    Riazi, H. R.; Danaee, I.; Peykari, M.

    2013-03-01

    Corrosion of carbon steel in sodium chloride solution was studied under ultraviolet illumination using weight loss, polarization, electrochemical impedance spectroscopy and current transient tests. The polarization test revealed an increase in the corrosion current density observed under UV illumination. The impedance spectroscopy indicated that the charge transfer resistance of the system was decreased by irradiation of UV light on a carbon steel electrode. The weight loss of carbon steel in solution increased under UV light, which confirms the results obtained from electrochemical measurements. We propose that the main effect of UV irradiation is on the oxide film, which forms on the surface. Thus, in presence of UV, the conductivity of oxide film might increase and lead to higher metal dissolution and corrosion rate.

  8. Large optical conductivity of Dirac semimetal Fermi arc surface states

    NASA Astrophysics Data System (ADS)

    Shi, Li-kun; Song, Justin C. W.

    2017-08-01

    Fermi arc surface states, a hallmark of topological Dirac semimetals, can host carriers that exhibit unusual dynamics distinct from that of their parent bulk. Here we find that Fermi arc carriers in intrinsic Dirac semimetals possess a strong and anisotropic light-matter interaction. This is characterized by a large Fermi arc optical conductivity when light is polarized transverse to the Fermi arc; when light is polarized along the Fermi arc, Fermi arc optical conductivity is significantly muted. The large surface spectral weight is locked to the wide separation between Dirac nodes and persists as a large Drude weight of Fermi arc carriers when the system is doped. As a result, large and anisotropic Fermi arc conductivity provides a novel means of optically interrogating the topological surfaces states of Dirac semimetals.

  9. A novel automotive headlight system based on digital micro-mirror devices and diffractive optical elements

    NASA Astrophysics Data System (ADS)

    Su, Ping; Song, Yuming; Ma, Jianshe

    2018-01-01

    The DMD (Digital Micro-mirror Device) has the advantages of high refresh rate and high diffraction efficiency, and these make it become an ideal loader of multiple modes illumination. DOEs (Diffractive Optical Element) have the advantages of high degree of freedom, light weight, easy to copy, low cost etc., and can be used to reduce the weight, complexity, cost of optical system. A novel automotive headlamp system using DMD as the light distribution element and a DOE as the light field modulation device is proposed in this paper. The pure phase DOE is obtained by the GS algorithm using Rayleigh-Sommerfeld diffraction integral model. Based on the standard automotive headlamp light intensity distribution in the target plane, the amplitude distribution of DMD is obtained by numerical simulation, and the grayscale diagram loaded on the DMD can be obtained accordingly. Finally, according to simulation result, the light intensity distribution in the target plane is proportional to the national standard, hence verifies the validity of the novel system. The novel illumination system proposed in this paper provides a reliable hardware platform for the intelligent headlamps.

  10. Novel insight of carotenoid and lipid biosynthesis and their roles in storage carbon metabolism in Chlamydomonas reinhardtii.

    PubMed

    Sun, Han; Mao, Xuemei; Wu, Tao; Ren, Yuanyuan; Chen, Feng; Liu, Bin

    2018-05-10

    Revenues of carotenoid and lipid biosynthesis under excess light and nitrogen starvation were firstly analyzed for the increased biomass value through carbon metabolism analysis. The results suggested excess light and nitrogen starvation resulted in carbon partitioning among protein, starch, lipid and carotenoid. Nitrogen starvation promoted more cellular lipid content than excess light, while excess light promoted carotenoid and polyunsaturated fatty acid accumulation. In the molecular level, the stresses redirected carbon skeletons into the central metabolite of pyruvate and oriented into starch and lipid as the primary and secondary carbon storage, respectively. Economic estimation revealed nitrogen starvation potentially increased 14.76 × 10 -6 and 72.11 × 10 -6  $/g revenues of biofuel production at per batch and cell weight scales, respectively. Excess light could increase 63.90 × 10 -6 and 19.21 × 10 -6  $/g at per cell weight scale of lipid and carotenoid, respectively. In combination with metabolism analysis, conversion procedure of process-compatible products was divided into four phases. Copyright © 2018 Elsevier Ltd. All rights reserved.

  11. Alterations in endogenous circadian rhythm of core temperature in senescent Fischer 344 rats

    NASA Technical Reports Server (NTRS)

    McDonald, R. B.; Hoban-Higgins, T. M.; Ruhe, R. C.; Fuller, C. A.; Horwitz, B. A.

    1999-01-01

    We assessed whether alterations in endogenous circadian rhythm of core temperature (CRT) in aging rats are associated with chronological time or with a biological marker of senescence, i.e., spontaneous rapid body weight loss. CRT was measured in male Fischer 344 (F344) rats beginning at age 689 days and then continuously until death. Young rats were also monitored. The rats were housed under constant dim red light at 24-26 degrees C, and core temperature was recorded every 10 min via biotelemetry. The CRT amplitude of the body weight-stable (presenescent) old rats was significantly less than that of young rats at all analysis periods. At the onset of spontaneous rapid weight loss (senescence), all measures of endogenous CRT differed significantly from those in the presenescent period. The suprachiasmatic nucleus (a circadian pacemaker) of the senescent rats maintained its light responsiveness as determined by an increase in c-fos expression after a brief light exposure. These data demonstrate that some characteristics of the CRT are altered slowly with chronological aging, whereas others occur rapidly with the onset of senescence.

  12. Small for gestational age and exposure to particulate air pollution in the early-life environment of twins.

    PubMed

    Bijnens, Esmée M; Derom, Catherine; Gielen, Marij; Winckelmans, Ellen; Fierens, Frans; Vlietinck, Robert; Zeegers, Maurice P; Nawrot, Tim S

    2016-07-01

    Several studies in singletons have shown that maternal exposure to ambient air pollutants is associated with restricted fetal growth. About half of twins have low birth weight compared with six percent in singletons. So far, no studies have investigated maternal air pollution exposure in association with birth weight and small for gestational age in twins. We examined 4760 twins of the East Flanders Prospective Twins Survey (2002-2013), to study the association between in utero exposure to air pollution with birth weight and small for gestational age. Maternal particulate air pollution (PM10) and nitric dioxide (NO2) exposure was estimated using a spatial temporal interpolation method over various time windows during pregnancy. In the total group of twins, we observed that higher PM10 and NO2 exposure during the third trimester was significantly associated with a lower birth weight and higher risk of small for gestational age. However, the association was driven by moderate to late preterm twins (32-36 weeks of gestation). In these twins born between 32 and 36 weeks of gestation, birth weight decreased by 40.2g (95% CI: -69.0 to -11.3; p=0.006) and by 27.3g (95% CI: -52.9 to -1.7; p=0.04) in association for each 10µg/m³ increment in PM10 and NO2 concentration during the third trimester. The corresponding odds ratio for small for gestational age were 1.68 (95% CI: 1.27-2.33; p=0.0003) and 1.51 (95% CI: 1.18-1.95; p=0.001) for PM10 or NO2, respectively. No associations between air pollution and birth weight or small for gestational age were observed among term born twins. Finally, in all twins, we found that for each 10µg/m³ increase in PM10 during the last month of pregnancy the within-pair birth weight difference increased by 19.6g (95% CI: 3.7-35.4; p=0.02). Assuming causality, an achievement of a 10µg/m³ decrease of particulate air pollution may account for a reduction by 40% in small for gestational age, in twins born moderate to late preterm. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. The effect of the processing and formulation parameters on the size of nanoparticles based on block copolymers of poly(ethylene glycol) and poly(N-isopropylacrylamide) with and without hydrolytically sensitive groups.

    PubMed

    Neradovic, D; Soga, O; Van Nostrum, C F; Hennink, W E

    2004-05-01

    Block copolymers of poly(ethylene glycol) (PEG) as a hydrophilic block and N-isopropylacrylamide (PNIPAAm) or poly (NIPAAm-co-N-(2-hydroxypropyl) methacrylamide-dilactate) (poly(NIPAAm-co-HPMAm-dilactate)) as a thermosensitive block, are able to self-assemble in water into nanoparticles above the cloud point (CP) of the thermosensitive block. The influence of processing and the formulation parameters on the size of the nanoparticles was studied using dynamic light scattering. PNIPAAm-b-PEG 2000 polymers were not suitable for the formation of small and stable particles. Block copolymers with PEG 5000 and 10000 formed relatively small and stable particles in aqueous solutions at temperatures above the CP of the thermosensitive block. Their size decreased with increasing molecular weight of the thermosensitive block, decreasing polymer concentration and using water instead of phosphate buffered saline as solvent. Extrusion and ultrasonication were inefficient methods to size down the polymeric nanoparticles. The heating rate of the polymer solutions was a dominant factor for the size of the nanoparticles. When an aqueous polymer solution was slowly heated through the CP, rather large particles (> or = 200 nm) were formed. Regardless the polymer composition, small nanoparticles (50-70 nm) with a narrow size distribution were formed, when a small volume of an aqueous polymer solution below the CP was added to a large volume of heated water. In this way the thermosensitive block copolymers rapidly pass their CP ('heat shock' procedure), resulting in small and stable nanoparticles.

  14. 47 CFR 80.925 - Electric light.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Electric light. 80.925 Section 80.925... MARITIME SERVICES Compulsory Radiotelephone Installations for Small Passenger Boats § 80.925 Electric light. (a) If the vessel is navigated at night an electric light or dial lights which clearly illuminate the...

  15. 47 CFR 80.925 - Electric light.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Electric light. 80.925 Section 80.925... MARITIME SERVICES Compulsory Radiotelephone Installations for Small Passenger Boats § 80.925 Electric light. (a) If the vessel is navigated at night an electric light or dial lights which clearly illuminate the...

  16. 47 CFR 80.925 - Electric light.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Electric light. 80.925 Section 80.925... MARITIME SERVICES Compulsory Radiotelephone Installations for Small Passenger Boats § 80.925 Electric light. (a) If the vessel is navigated at night an electric light or dial lights which clearly illuminate the...

  17. 47 CFR 80.925 - Electric light.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Electric light. 80.925 Section 80.925... MARITIME SERVICES Compulsory Radiotelephone Installations for Small Passenger Boats § 80.925 Electric light. (a) If the vessel is navigated at night an electric light or dial lights which clearly illuminate the...

  18. 47 CFR 80.925 - Electric light.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Electric light. 80.925 Section 80.925... MARITIME SERVICES Compulsory Radiotelephone Installations for Small Passenger Boats § 80.925 Electric light. (a) If the vessel is navigated at night an electric light or dial lights which clearly illuminate the...

  19. Construction of a cost effective optical tweezers for manipulation of birefringent materials using circularly polarized light

    NASA Astrophysics Data System (ADS)

    McMahon, Allison; Sauncy, Toni

    2008-10-01

    Light manipulation is a very powerful tool in physics, biology, and chemistry. There are several physical principles underlying the apparatus known as the ``optical tweezers,'' the term given to using focused light to manipulate and control small objects. By carefully controlling the orientation and position of a focused laser beam, dielectric particles can be effectively trapped and manipulated. We have designed a cost efficient and effective undergraduate optical tweezers apparatus by using standard ``off the shelf'' components and starting with a standard undergraduate laboratory microscope. Images are recorded using a small CCD camera interfaced to a computer and controlled by LabVIEW^TM software. By using wave plates to produce circular polarized light, rotational motion can be induced in small particles of birefringent materials such as calcite and mica.

  20. Dim light at night disrupts molecular circadian rhythms and increases body weight.

    PubMed

    Fonken, Laura K; Aubrecht, Taryn G; Meléndez-Fernández, O Hecmarie; Weil, Zachary M; Nelson, Randy J

    2013-08-01

    With the exception of high latitudes, life has evolved under bright days and dark nights. Most organisms have developed endogenously driven circadian rhythms that are synchronized to this daily light/dark cycle. In recent years, humans have shifted away from the naturally occurring solar light cycle in favor of artificial and sometimes irregular light schedules produced by electric lighting. Exposure to unnatural light cycles is increasingly associated with obesity and metabolic syndrome; however, the means by which environmental lighting alters metabolism are poorly understood. Thus, we exposed mice to dim light at night and investigated changes in the circadian system and metabolism. Here we report that exposure to ecologically relevant levels of dim (5 lux) light at night altered core circadian clock rhythms in the hypothalamus at both the gene and protein level. Circadian rhythms in clock expression persisted during light at night; however, the amplitude of Per1 and Per2 rhythms was attenuated in the hypothalamus. Circadian oscillations were also altered in peripheral tissues critical for metabolic regulation. Exposure to dimly illuminated, as compared to dark, nights decreased the rhythmic expression in all but one of the core circadian clock genes assessed in the liver. Additionally, mice exposed to dim light at night attenuated Rev-Erb expression in the liver and adipose tissue. Changes in the circadian clock were associated with temporal alterations in feeding behavior and increased weight gain. These results are significant because they provide evidence that mild changes in environmental lighting can alter circadian and metabolic function. Detailed analysis of temporal changes induced by nighttime light exposure may provide insight into the onset and progression of obesity and metabolic syndrome, as well as other disorders involving sleep and circadian rhythm disruption.

Top