Giddings, V L; Kurtz, S M; Jewett, C W; Foulds, J R; Edidin, A A
2001-07-01
Polymethylmethacrylate (PMMA) bone cement is used in total joint replacements to anchor implants to the underlying bone. Establishing and maintaining the integrity of bone cement is thus of critical importance to the long-term outcome of joint replacement surgery. The goal of the present study was to evaluate the suitability of a novel testing technique, the small punch or miniaturized disk bend test, to characterize the elastic modulus and fracture behavior of PMMA. We investigated the hypothesis that the crack initiation behavior of PMMA during the small punch test was sensitive to the test temperature. Miniature disk-shaped specimens, 0.5 mm thick and 6.4 mm in diameter, were prepared from PMMA and Simplex-P bone cement according to manufacturers' instructions. Testing was conducted at ambient and body temperatures, and the effect of test temperature on the elastic modulus and fracture behavior was statistically evaluated using analysis of variance. For both PMMA materials, the test temperature had a significant effect on elastic modulus and crack initiation behavior. At body temperature, the specimens exhibited "ductile" crack initiation, whereas at room temperature "brittle" crack initiation was observed. The small punch test was found to be a sensitive and repeatable test method for evaluating the mechanical behavior of PMMA. In light of the results of this study, future small punch testing should be conducted at body temperature.
Determination of Material Strengths by Hydraulic Bulge Test.
Wang, Hankui; Xu, Tong; Shou, Binan
2016-12-30
The hydraulic bulge test (HBT) method is proposed to determine material tensile strengths. The basic idea of HBT is similar to the small punch test (SPT), but inspired by the manufacturing process of rupture discs-high-pressure hydraulic oil is used instead of punch to cause specimen deformation. Compared with SPT method, the HBT method can avoid some of influence factors, such as punch dimension, punch material, and the friction between punch and specimen. A calculation procedure that is entirely based on theoretical derivation is proposed for estimate yield strength and ultimate tensile strength. Both conventional tensile tests and hydraulic bulge tests were carried out for several ferrous alloys, and the results showed that hydraulic bulge test results are reliable and accurate.
NASA Astrophysics Data System (ADS)
Hassan, A.-P.
2014-07-01
The small-punch testing (SPT) method is used for determining the mechanical properties of AISI 410 (0.14% C, 12% Cr) stainless steel. A thin disc-shaped specimen with known mechanical properties is pressed with a small ball until the appearance of cracks in the former. The load - displacement curves are recorded. Computation of the yield strength and fracture energy by the curve obtained and by known formulas shows good convergence with the characteristics obtained by standard testing.
Experimental and Computational Study of Ductile Fracture in Small Punch Tests
Bargmann, Swantje; Hähner, Peter
2017-01-01
A unified experimental-computational study on ductile fracture initiation and propagation during small punch testing is presented. Tests are carried out at room temperature with unnotched disks of different thicknesses where large-scale yielding prevails. In thinner specimens, the fracture occurs with severe necking under membrane tension, whereas for thicker ones a through thickness shearing mode prevails changing the crack orientation relative to the loading direction. Computational studies involve finite element simulations using a shear modified Gurson-Tvergaard-Needleman porous plasticity model with an integral-type nonlocal formulation. The predicted punch load-displacement curves and deformed profiles are in good agreement with the experimental results. PMID:29039748
Experimental and Computational Study of Ductile Fracture in Small Punch Tests.
Gülçimen Çakan, Betül; Soyarslan, Celal; Bargmann, Swantje; Hähner, Peter
2017-10-17
A unified experimental-computational study on ductile fracture initiation and propagation during small punch testing is presented. Tests are carried out at room temperature with unnotched disks of different thicknesses where large-scale yielding prevails. In thinner specimens, the fracture occurs with severe necking under membrane tension, whereas for thicker ones a through thickness shearing mode prevails changing the crack orientation relative to the loading direction. Computational studies involve finite element simulations using a shear modified Gurson-Tvergaard-Needleman porous plasticity model with an integral-type nonlocal formulation. The predicted punch load-displacement curves and deformed profiles are in good agreement with the experimental results.
Kurtz, S M; Siskey, R; Reitman, M
2010-05-01
The objectives of this study were three-fold: (1) to determine the applicability of the small punch test to characterize Bionate 80A polycarbonate urethane (PCU) acetabular implants; (2) to evaluate the susceptibility of PCU acetabular implants to exhibit degradation of mechanical behavior following gamma irradiation in air and accelerated aging; and (3) to compare the oxidation of gamma-air sterilized PCU following accelerated aging and 5 years of natural shelf aging. In addition to attenuated total reflectance-Fourier transform infrared spectroscopy, we also adapted a miniature specimen mechanical test, the small punch test, for the deformable PCU cups. Accelerated aging was performed using ASTM F2003, a standard test that represents a severe oxidative challenge. The results of this study suggest that the small punch test is sufficiently sensitive and reproducible to discriminate slight differences in the large-deformation mechanical behavior of Bionate 80A following accelerated aging. The gamma-air sterilized PCU had a reduction of 9% in ultimate load after aging. Five years of shelf aging had little effect on the mechanical properties of the PCU. Overall, our findings suggest that the Bionate 80A material has greater oxidative stability than ultra-high molecular weight polyethylene following gamma irradiation in air and exposure to a severe oxidative challenge. (c) 2010 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Deng, Qihuang; Fan, Yuchi; Wang, Lianjun; Xiong, Zhi; Wang, Hongzhi; Li, Yaogang; Zhang, Qinghong; Kawasaki, Akira; Jiang, Wan
2012-01-01
Pb(Zr,Ti)O3 (PZT) ceramics were prepared by the conventional mixed oxide method, and the strength of the resultant PZT ceramics was evaluated using modified small punch (MSP) tests. Load-displacement curve test results showed that the crack-initiation and fracture strengths of PZT ceramics decreased after polarization. The effect of the polarization accelerated the fatigue properties of PZT ceramics. Scanning electron microscopy (SEM) results showed that microcracks were formed before the maximum load in the MSP test, and the first load drop corresponded to crack initiation.
Maietta, Saverio; Russo, Teresa; De Santis, Roberto; Ronca, Dante; Riccardi, Filomena; Martorelli, Massimo; Gloria, Antonio
2018-01-01
Experimental/theoretical analyses have already been performed on poly(ε-caprolactone) (PCL) loaded with organic–inorganic fillers (PCL/TiO2 and PCL/ZrO2) to find a correlation between the results from the small punch test and Young’s modulus of the materials. PCL loaded with Ti2 (PCL = 12, TiO2 = 88 wt %) and Zr2 (PCL = 12, ZrO2 = 88 wt %) hybrid fillers showed better performances than those obtained for the other particle composition. In this context, the aim of current research is to provide further insight into the mechanical properties of PCL loaded with sol–gel-synthesized organic–inorganic hybrid fillers for bone tissue engineering. For this reason, theoretical analyses were performed by the finite element method. The results from the small punch test and Young’s modulus of the materials were newly correlated. The obtained values of Young’s modulus (193 MPa for PCL, 378 MPa for PCL/Ti2 and 415 MPa for PCL/Zr2) were higher than those obtained from a previous theoretical modelling (144 MPa for PCL, 282 MPa for PCL/Ti2 and 310 MPa for PCL/Zr2). This correlation will be an important step for the evaluation of Young’s modulus, starting from the small punch test data. PMID:29466299
Maietta, Saverio; Russo, Teresa; Santis, Roberto De; Ronca, Dante; Riccardi, Filomena; Catauro, Michelina; Martorelli, Massimo; Gloria, Antonio
2018-02-21
Experimental/theoretical analyses have already been performed on poly(ε-caprolactone) (PCL) loaded with organic-inorganic fillers (PCL/TiO₂ and PCL/ZrO₂) to find a correlation between the results from the small punch test and Young's modulus of the materials. PCL loaded with Ti2 (PCL = 12, TiO₂ = 88 wt %) and Zr2 (PCL = 12, ZrO₂ = 88 wt %) hybrid fillers showed better performances than those obtained for the other particle composition. In this context, the aim of current research is to provide further insight into the mechanical properties of PCL loaded with sol-gel-synthesized organic-inorganic hybrid fillers for bone tissue engineering. For this reason, theoretical analyses were performed by the finite element method. The results from the small punch test and Young's modulus of the materials were newly correlated. The obtained values of Young's modulus (193 MPa for PCL, 378 MPa for PCL/Ti2 and 415 MPa for PCL/Zr2) were higher than those obtained from a previous theoretical modelling (144 MPa for PCL, 282 MPa for PCL/Ti2 and 310 MPa for PCL/Zr2). This correlation will be an important step for the evaluation of Young's modulus, starting from the small punch test data.
Shear Punch Testing on ATR Irradiated MA956 FeCrAl Alloy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saleh, Tarik A.; Quintana, Matthew Estevan; Romero, Tobias J.
2017-06-13
The shear punch testing of irradiated and control MA956 (FeCrAl) Alloy from the NSUF-ATR-UCSB irradiation is presented. This is the first data taken on a new shear punch fixture design to test three 1.5mm punches from each 8mm x 0.5mm Disc Multipurpose Coupon (DMC). Samples were irradiated to 6.1dpa at a temperature of 315°C and 6.2 dpa at 400°C.
Characterizing the stretch-flangeability of hot rolled multiphase steels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pathak, N.; Butcher, C.; Worswick, M.
2013-12-16
Hole expansion tests are commonly used to characterize the edge stretching limit of a material. Traditionally, a conical punch is used to expand a punched hole until a through-thickness crack appears. However, many automotive stretch flanging operations involve in-plane edge stretching that is best captured with a flat punch. In this paper, hole expansion tests were carried out on two different hot-rolled multiphase steels using both flat and conical punches. The fracture mechanisms for both punch types were investigated using scanning electron microscopy (SEM)
Zanatta, Rayssa Ferreira; Barreto, Bruno de Castro Ferreira; Xavier, Tathy Aparecida; Versluis, Antheunis; Soares, Carlos José
2015-02-01
This study evaluated the influence of punch and base orifice diameters on push-out test results by means of finite element analysis (FEA). FEA was performed using 3D models of the push-out test with 3 base orifice diameters (2.5, 3.0, and 3.5 mm) and 3 punch diameters (0.5, 1.0, and 1.5 mm) using MARC/MENTAT (MSC.Software). The image of a cervical slice from a root restored with a fiberglass post was used to construct the models. The mechanical properties of dentin, post, and resin cement were obtained from the literature. Bases and punches were constructed as rigid bodies. A 10-N force was applied by the punch in the center of the post in a nonlinear contact analysis. Modified von Mises stress, maximum principal stress, as well as shear and normal stress components were calculated. Both punch and base orifice sizes influenced the stress distribution of the push-out test. Bases with larger diameters and punches with smaller diameters caused higher stress in dentin and at the dentin/cement interface. FEA showed that the diameter of the orifice base had a more significant influence on the stress distribution than did the punch diameter. For this reason, both factors should be taken into account during push-out experimental tests.
NASA Astrophysics Data System (ADS)
Cao, X. Y.; Zhu, P.; Ding, X. F.; Lu, Y. H.; Shoji, T.
2017-04-01
Microstructural evolution and mechanical property change of E308L stainless steel weld overlay cladding aged at 400 °C for 400, 1000 and 5000 h were investigated by transmission electron microscope (TEM) and small punch test (SPT). The results indicated that thermal aging had no obvious effect on the volume fraction of ferrite, but can cause microstructural evolution by spinodal decomposotion and G-phase precipitation in the ferrite phase. Spinodal decomposition took place after aging up to 1000 h, while G-phase formed along dislocations, and growed up to 2-11 nm after aging for 5000 h. The total energy for inducing deformation and fracture by the small punch tests decreased with the increase of thermal aging time, and this decline was associated with spinodal decomposition and G-phase precipitation. Plastic deformation of the aged ferrite proceeded via formation of curvilinear slip bands. Nucleation of microcracks occurred at the δ/γ interface along the slip bands. The hardening of the ferrite and high stress concentration on δ/γ phase interface resulted in brittle fracture and phase boundary separation after thermal aging.
Bruzas, Vidas; Kamandulis, Sigitas; Venckunas, Tomas; Snieckus, Audrius; Mockus, Pranas
2018-03-01
During competition, a boxer must continue to deliver high-impact punches despite increasing fatigue. It is unclear whether the effects of plyometric training using external weights are transferred to sport-specific movements such as punching. The aim of the study was to investigate the effects of a 4-week cycle of plyometric training with external weights on punching ability. The study involved eight male amateur boxers aged 22.3±2.5 years with at least 7 years of competitive experience. They performed 12 plyometric training sessions, each comprising eight exercises of various muscle groups performed at maximum movement velocity. Six drills were performed with external weights, and two drills were performed using the body weight as resistance. All exercises required coordination. The punching ability was tested at baseline and after the 4 weeks of training using the Kiktest-100 boxing bag. The force of single punches and the frequency of punches within a series did not change from before to after the 4 weeks, except for increased power in the rear-hand low punch (P<0.05). However, there was an increase in summative force and energy output within 3 s and 8 s, and in a series of eight 8-s tests (P<0.05). Four weeks of plyometric training with external weights did not change the maximum punching power or movement frequency significantly, but had a beneficial effect on punching power endurance in boxers.
A new virtual instrument for estimating punch velocity in combat sports.
Urbinati, K S; Scheeren, E; Nohama, P
2013-01-01
For improving the performance in combat sport, especially percussion, it is necessary achieving high velocity in punches and kicks. The aim of this study was to evaluate the applicability of 3D accelerometry in a Virtual Instrumentation System (VIS) designed for estimating punch velocity in combat sports. It was conducted in two phases: (1) integration of the 3D accelerometer with the communication interface and software for processing and visualization, and (2) applicability of the system. Fifteen karate athletes performed five gyaku zuki type punches (with reverse leg) using the accelerometer on the 3rd metacarpal on the back of the hand. It was performed nonparametric Mann-Whitney U-test to determine differences in the mean linear velocity among three punches performed sequentially (p <0.05). The maximum velocities measured varied in the range of 10 and 10.2 m/s and the mean velocities from 6 to 6.8 m/s. There was no difference on the mean velocity for the tested punches. The VIS demonstrated regularity and proper functionality for assessing punches in combat sport.
Meniscal shear stress for punching.
Tuijthof, Gabrielle J M; Meulman, Hubert N; Herder, Just L; van Dijk, C Niek
2009-01-01
Experimental determination of the shear stress for punching meniscal tissue. Meniscectomy (surgical treatment of a lesion of one of the menisci) is the most frequently performed arthroscopic procedure. The performance of a meniscectomy is not optimal with the currently available instruments. To design new instruments, the punching force of meniscal tissue is an important parameter. Quantitative data are unavailable. The meniscal punching process was simulated by pushing a rod through meniscal tissue at constant speed. Three punching rods were tested: a solid rod of Oslash; 3.00 mm, and two hollow tubes (Oslash; 3.00-2.60 mm) with sharpened cutting edges of 0.15 mm and 0.125 mm thick, respectively. Nineteen menisci acquired from 10 human cadaveric knee joints were punched (30 tests). The force and displacement were recorded from which the maximum shear stress was determined (average added with three times the standard deviation). The maximum shear stress for the solid rod was determined at 10.2 N/mm2. This rod required a significantly lower punch force in comparison with the hollow tube having a 0.15 mm cutting edge (plt;0.01). The maximum shear stress for punching can be applied to design instruments, and virtual reality training environments. This type of experiment is suitable to form a database with material properties of human tissue similar to databases for the manufacturing industry.
Computational study of graphene-based vertical field effect transistor
NASA Astrophysics Data System (ADS)
Chen, Wenchao; Rinzler, Andrew; Guo, Jing
2013-03-01
Poisson and drift-diffusion equations are solved in a three-dimensional device structure to simulate graphene-based vertical field effect transistors (GVFETs). Operation mechanisms of the GVFET with and without punched holes in the graphene source contact are presented and compared. The graphene-channel Schottky barrier can be modulated by gate electric field due to graphene's low density of states. For the graphene contact with punched holes, the contact barrier thinning and lowering around punched hole edge allow orders of magnitude higher tunneling current compared to the region away from the punched hole edge, which is responsible for significant performance improvement as already verified by experiments. Small hole size is preferred due to less electrostatic screening from channel inversion layer, which gives large electric field around the punched hole edge, thus, leading to a thinner and lower barrier. Bilayer and trilayer graphenes as the source contact degrade the performance improvement because stronger electrostatic screening leads to smaller contact barrier lowering and thinning. High punched hole area percentage improves current performance by allowing more gate electric field to modulate the graphene-channel barrier. Low effective mass channel material gives better on-off current ratio.
Development of a low energy micro sheet forming machine
NASA Astrophysics Data System (ADS)
Razali, A. R.; Ann, C. T.; Shariff, H. M.; Kasim, N. I.; Musa, M. A.; Ahmad, A. F.
2017-10-01
It is expected that with the miniaturization of materials being processed, energy consumption is also being `miniaturized' proportionally. The focus of this study was to design a low energy micro-sheet-forming machine for thin sheet metal application and fabricate a low direct current powered micro-sheet-forming machine. A prototype of low energy system for a micro-sheet-forming machine which includes mechanical and electronic elements was developed. The machine was tested for its performance in terms of natural frequency, punching forces, punching speed and capability, energy consumption (single punch and frequency-time based). Based on the experiments, the machine can do 600 stroke per minute and the process is unaffected by the machine's natural frequency. It was also found that sub-Joule of power was required for a single stroke of punching/blanking process. Up to 100micron thick carbon steel shim was successfully tested and punched. It concludes that low power forming machine is feasible to be developed and be used to replace high powered machineries to form micro-products/parts.
NASA Astrophysics Data System (ADS)
Pilewska, Wiesława; Buśko, Krzysztof; Nikolaidis, Pantelis Theodoros
2017-11-01
The main aim of the study was to design a new system to measure punching forces in boxers. In addition, the study examined whether there were any relationship between force of punches and power of jump. A total of 9 boxers (age: 17.5±1.2 years, body height: 174.1±8.1 cm, body mass: 73.9±11.8 kg) participated in the study. The punching bag was equipped with acceleration transducers and gyroscopes embedded in a cylinder covered with a layer to absorb shock as well as a set of colour signal diodes. Value of the punching bag's acceleration was used for calculating: strike force; the punching location on the bag; and time of a strike. The relative error of force calculation was 3%; the relative error in acceleration measurement was less than 1%. The maximal straight of rear and lead punching forces were 1702.4±497.8 N and 1262.0±417.7 N in boxers, respectively. Strong correlations were found between the punching force and power of lower limbs developed for the ACMJ, CMJ and SPJ jump. Height of rise of the body mass centre and punching force correlated insignificantly. Based on these findings, it was concluded that the modified punching bag is a good diagnostic tool for combat sports. The measurement of power during the jump may be a good diagnostic test in boxers.
Comparison of tissue loss by different punches: A new A-design.
Ahmad, Muhammad
2018-06-19
To compare the amount of tissue loss using different FUE punches. The study was conducted in 5 patients undergoing hair restoration surgery by FUE. Four different kinds of punches were used, that is, sharp, blunt, serrated, and new "A-design." All the punches had a total cutting edge of 0.8 mm. In each patient, 4 punches were used to make insertion at right angle with the skin. Immediately after the punch use, the diameter of the hole was measured. The same areas were also measured after 24 hours and after 1 month. The data were collected and analyzed by Multiple t test (with Bonferroni's correction). The average size of the wound immediately at the end of the procedure was 0.826 mm for sharp, 0.858 mm for blunt, 0.892 mm for serrated, and 0.932 mm for A-design. Similarly, the wounds decreased to 0.752, 0.778, 0.774, and 0.696 mm for sharp, blunt, serrated, and A-design, respectively, after 24 hours. The final wound/scar size was 0.640 mm for punch, 0.660 mm for blunt punch, 0.668 mm for serrated punch, and 0.598 mm for A-design punch after 1 month. The new A-design resulted in the minimum scar size after 1 month. © 2018 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Shinohara, K.; Lucas, G. E.; Odette, G. R.
1985-08-01
The irradiation hardening response of five metals irradiated in RTNS-II was investigated using a combination of ball microhardness and shear punch test techniques. The specimens were transmission electron microscopy disks of pure nickel, Ni-5wt%Si, pure iron, solution annealed prime candidate alloy (PCA) for Path A, and 40% cold worked MFE 316 stainless steel. Specimens were irradiated in RTNS-II to fluences in the range 6 × 10 16 to 6 × 10 17 n/cm 2. Only limited ball microhardness data could be obtained because of disk thickness. However, the ball microhardness data obtained were in good agreement with shear punch data. It was found that the pure metals exhibited little hardening after exposure to fluences of ~1 × 10 17 n/cm 2, but Ni-5 Si exhibited significant hardening after 6 × 10 17 n/cm 2. Hardening in PCA was similar to that observed in solution annealed 316 stainless steel; and hardening in 40% cold worked MFE 316 was relatively small after 6 × 10 17 n/cm 2. The Ni-5 Si response may be due to irradiation induced precipitation.
Super Dielectric Material Based Capacitors: Punched Membrane/Gel
NASA Astrophysics Data System (ADS)
Petty, C. W.; Phillips, J.
2018-05-01
Extensive testing showed, as predicted, that punched membranes, filled with a gel containing aqueous salt solutions, behave as superdielectric materials (SDM). Punched membrane superdielectrics employed herein consisted of a commercial cellulose based membrane material, Celgard 16 μ thick, a material frequently used as a separator material in supercapacitors, into which macroscopic holes (ca. 2.5 mm) were punched with a laser cutter, and the holes subsequently filled with a gel-like material composed of fumed silica, NaCl and water. The gross dielectric constants measured, generally > 105, and the energy densities, > 40 J/cm3 during slow discharge, were in the range expected for superdielectric materials. The measured capacitance and energy density tracked the number of holes punched/area filled with the dielectric gel. Also, the observed power law decrease in all parameters including energy, power and capacitance, followed the same trends observed in other classes of SDM. Control studies included testing dielectrics composed of Celgard into which no holes were punched, but the SDM gel spread, also produced values consistent with the SDM model: no measurable capacitance using the standard protocol. Finally, the values measured suggest these materials rival the energy density of some common battery types at low discharge rates, and surpass the best commercial supercapacitors at low discharge rates.
NASA Astrophysics Data System (ADS)
Ishii, T.; Ohmi, M.; Saito, J.; Hoshiya, T.; Ooka, N.; Jitsukawa, S.; Eto, M.
2000-12-01
Small specimen test techniques (SSTT) are essential to use an accelerator-driven deuterium-lithium stripping reaction neutron source for the study of fusion reactor materials because of the limitation of the available irradiation volume. A remote-controlled small punch (SP) test machine was developed at the hot laboratory of the Japan Materials Testing Reactor (JMTR) in the Japan Atomic Energy Research Institute (JAERI). This report describes the SP test method and machine for use in a hot cell, and test results on irradiated ferritic steels. The specimen was either a coupon 10×10×0.25 mm 3 or a TEM disk 3 mm in diameter by 0.25 mm in thickness. Tests can be performed at temperatures ranging from 93 to 1123 K in a vacuum or in an inert gas environment. The ductile to brittle transition temperature of the irradiated ferritic steel as determined by the SP test is also evaluated.
Shelter effect efficacy of sand fences: A comparison of systems in a wind tunnel
NASA Astrophysics Data System (ADS)
Wang, Tao; Qu, Jianjun; Ling, Yuquan; Liu, Benli; Xiao, Jianhua
2018-02-01
The Lanzhou-Xinjiang High-speed Railway runs through an expansive wind area in the Gobi Desert and blown-sand disasters are a critical issue affecting its operation. To strengthen the blown-sand disaster shelter systems along the railway, the shelter effects of punching plate and wire mesh fences with approximately equal porosity (48%) were simulated in a wind tunnel. The experimental results showed that the wind velocity was reduced to a higher extent by the punching plate fence than by the wire mesh fence. When a single row of sand fencing was used, the wind velocity reduction coefficient (Rcz) values downwind of the punching plate fence and wire mesh fence reached 71.77% and 39.37%, respectively. When double rows of sand fencing were used, the Rcz values downwind of the punching plate and wire mesh fences were approximately 87.48% and 60.81%, respectively. For the flow field structure on the leeward side of the fencing, the deceleration zone behind the punching plate fence was more pronounced than that behind the wire mesh fence. The vortex zone was not obvious and the reverse flow disappeared for both types of fences, which indicates that the turbulent intensity was small. The sand-trapping efficiency of the wire mesh fence was close to that of punching plate fence. When a single row of sand fencing was set up, the total mass flux density decreased, on average, by 65.85% downwind of the wire mesh fence, and 75.06% downwind of the punching plate fence; when double rows of sand fencing were present, the total mass flux density decreased, on average, by 84.53% downwind of the wire mesh fence and 84.51% downwind of the punching plate fence. In addition, the wind-proof efficiency and the sand-proof efficiency of the punching plate fence and the wire mesh fence decreased with increasing wind velocities. Consequently, punching plate and wire mesh fences may effectively control the sand hazard in the expansive wind area of the Gobi Desert.
The structure-property relationships of powder processed Fe-Al-Si alloys
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prichard, Paul D.
1998-02-23
Iron-aluminum alloys have been extensively evaluated as semi-continuous product such as sheet and bar, but have not been evaluated by net shape P/M processing techniques such as metal injection molding. The alloy compositions of iron-aluminum alloys have been optimized for room temperature ductility, but have limited high temperature strength. Hot extruded powder alloys in the Fe-Al-Si system have developed impressive mechanical properties, but the effects of sintering on mechanical properties have not been explored. This investigation evaluated three powder processed Fe-Al-Si alloys: Fe-15Al, Fe-15Al-2.8Si, Fe-15Al-5Si (atomic %). The powder alloys were produced with a high pressure gas atomization (HPGA) processmore » to obtain a high fraction of metal injection molding (MIM) quality powder (D 84 < 32 μm). The powders were consolidated either by P/M hot extrusion or by vacuum sintering. The extruded materials were near full density with grain sizes ranging from 30 to 50 μm. The vacuum sintering conditions produced samples with density ranging from 87% to 99% of theoretical density, with an average grain size ranging from 26 μm to 104 μm. Mechanical property testing was conducted on both extruded and sintered material using a small punch test. Tensile tests were conducted on extruded bar for comparison with the punch test data. Punch tests were conducted from 25 to 550 C to determine the yield strength, and fracture energy for each alloy as a function of processing condition. The ductile to brittle transition temperature (DBTT) was observed to increase with an increasing silicon content. The Fe-15Al-2.8Si alloy was selected for more extensive testing due to the combination of high temperature strength and low temperature toughness due to the two phase α + DO 3 structure. This investigation provided a framework for understanding the effects of silicon in powder processing and mechanical property behavior of Fe-Al-Si alloys.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, K.; Meng, W. J.; Mei, F.
2011-02-01
A single crystal Al specimen was molded at room temperature with long, rectangular, strip diamond punches. Quantitative molding response curves were obtained at a series of punch widths, ranging from 5 {micro}m to 550 nm. A significant size effect was observed, manifesting itself in terms of significantly increasing characteristic molding pressure as the punch width decreases to 1.5 {micro}m and below. A detailed comparison of the present strip punch molding results was made with Berkovich pyramidal indentation on the same single crystal Al specimen. The comparison reveals distinctly different dependence of the characteristic pressure on corresponding characteristic length. The presentmore » results show the feasibility of micro-/nano-scale compression molding as a micro-/nano-fabrication technique, and offer an experimental test case for size-dependent plasticity theories.« less
Ogden, Samantha J; Horton, Jeffrey K; Stubbs, Simon L; Tatnell, Peter J
2015-01-01
The 1.2 mm Electric Coring Tool (e-Core™) was developed to increase the throughput of FTA(™) sample collection cards used during forensic workflows and is similar to a 1.2 mm Harris manual micro-punch for sampling dried blood spots. Direct short tandem repeat (STR) DNA profiling was used to compare samples taken by the e-Core tool with those taken by the manual micro-punch. The performance of the e-Core device was evaluated using a commercially available PowerPlex™ 18D STR System. In addition, an analysis was performed that investigated the potential carryover of DNA via the e-Core punch from one FTA disc to another. This contamination study was carried out using Applied Biosystems AmpflSTR™ Identifiler™ Direct PCR Amplification kits. The e-Core instrument does not contaminate FTA discs when a cleaning punch is used following excision of discs containing samples and generates STR profiles that are comparable to those generated by the manual micro-punch. © 2014 American Academy of Forensic Sciences.
Task Identification and Evaluation System (TIES)
1991-08-01
Caliorate A N/AVh-11A- iUD -test -sets 127. Calibrate AN/AWII1-55 ASCU test setsI - 128. Calibrate 5001L11 tally punched tape readersI- 129. Perform...11AKHbD test sets -- 132. ?erform fault isolation of U4/AWN-55 ASCU -test sets -- 133. Perform fault isolation of 500 R.M tally punched tape I...AIN/AVM1-11A HfLM test sets- 137. Perf-orm self-tests of AL%/AWL-S5 ASCU test sets G. !MAI.T.T!ING A-7D_ ANUAL TEST SETS 138. Adjust SM-661/AS-388air
NASA Astrophysics Data System (ADS)
Kedous-Lebouc, A.; Messal, O.; Youmssi, A.
2017-03-01
Mechanical punching of electrical steels causes a degradation of their magnetic characteristics which can extend several millimeters from the cut edge. So, in the field of industrial applications, particularly that of small electrical machines, the stator core made of rigid and thin teeth would be subject to more losses. Thus, this topic of the effect of punching has to be submitted to further deep characterization and development in order to give some insight into the different mechanisms. In this framework, this paper evaluates the combined effect of punching and frequency on the magnetization curve and iron losses in thin SiFe and CoFe soft magnetic sheets. These alloys are typically suitable for the manufacture of high-speed electrical machines used in on board applications (aircraft power generators, automotive, etc). Two SiFe alloys and a CoFe alloy have been investigated. First, different rectangular samples of variable width (15, 10, 5, 3 mm) have been industrially punched. Then, a dedicated magnetic characterization has been made, using basically a mini-Epstein frame. Measurements have been performed from 50 Hz to 1 kHz and from 0.3 T to near saturation. Both rolling and transverse directions have been considered. Finally, a first attempt to predict the degradation due to the punching is presented. A useful description of the magnetic permeability as a function of B and f is given and the degradation parameters are estimated based on the knowledge of the reference permeability.
NASA Astrophysics Data System (ADS)
Senn, S.; Liewald, M.
2017-09-01
Deep drawn parts often do have complex designs and, therefore, must be trimmed or punched subsequently in a second stage. Due to the complex part geometry, most punching areas do reveal critical slant angle (angle between part surface and ram movement direction) different to perpendicular direction. Piercing within a critical range of slant angle may lead to severe damage of the cutting tool. Consequently, expensive cam units are required to transform the ram moving direction in order to perform the piercing process perpendicularly to the local part surface. For modern sheet metals, however, the described critical angle of attack has not been investigated adequately until now. Therefore, cam units are used in cases in which regular piercing with high slant angle wouldn’t be possible. Purpose of this study is to investigate influencing factors and their effect on punch damage during piercing of high strength steels with slant angles. Therefore, a modular shearing tool was designed, which allows to simply switch die parts to vary cutting clearance and cutting angle. The target size of the study is to measure the lateral deviation of the punch which is monitored by an eddy current sensor. The sensor is located in the downholder and measures the lateral punch deviation in-line during manufacturing. The deviation is mainly influenced by slant angle of workpiece surface. In relation to slang angle and sheet thickness the clearance has a small influence on the measured punch deflection.
Physiological profile of a professional boxer preparing for Title Bout: A case study.
Halperin, Israel; Hughes, Steven; Chapman, Dale W
2016-10-01
This study aimed to (1) profile a professional boxer (23 years and 80 kg) with boxing-specific, muscle function, aerobic capacity and body composition tests, and (2) quantify how these measures varied during an 8-week preparation phase leading to, and post a state-Title Bout fought in the 76.2-kg class. A series of boxing-specific and muscle function tests were completed on 11 occasions: 9 prior and twice after the bout, each separated by approximately 2 weeks. The boxing test included 36 maximal punches (9 of each: lead and rear straights, lead and rear hooks) to a punching integrator measuring forces and velocity. Muscle function tests included countermovement jump, drop-jumps, isometric mid-thigh pull and isometric bench-press. Body composition was assessed using skin-fold measurements on three occasions and one dual energy X-ray absorptiometry scan. Aerobic capacity was assessed using 2 VO2 max tests. Leading up to the bout, performance decreased in isometric mid-thigh pull (8%), isometric bench-press (5%), countermovement jump (15%) and impact forces in 3 of 4 punches (4%-7%). Whereas measures of dynamic and isometric muscle function remained depressed or unchanged post competition, punching forces (6%-15%) and aerobic power (6%) increased. Data suggest the athlete may have super-compensated following rest as fatigue dissipated and further adaptation occurred.
NASA Astrophysics Data System (ADS)
Panicker, Sudhy S.; Prasad, K. Sajun; Basak, Shamik; Panda, Sushanta Kumar
2017-08-01
In the present work, uniaxial tensile tests were carried out to evaluate the stress-strain response of AA2014, AA5052 and AA6082 aluminum alloys at four temperatures: 303, 423, 523 and 623 K, and three strain rates: 0.0022, 0.022 and 0.22 s-1. It was found that the Cowper-Symonds model was not a robust constitutive model, and it failed to predict the flow behavior, particularly the thermal softening at higher temperatures. Subsequently, a comparative study was made on the capability of Johnson-Cook (JC), modified Zerilli-Armstrong (m-ZA), modified Arrhenius (m-ARR) and artificial neural network (ANN) for modeling the constitutive behavior of all the three aluminum alloys under the mentioned strain rates and temperatures. Also, the improvement in formability of the materials was evaluated at an elevated temperature of 623 K in terms of cup height and maximum safe strains by conducting cylindrical cup deep drawing experiments under two different punch speeds of 4 and 400 mm/min. The cup heights increased during warm deep drawing due to thermal softening and increase in failure strains. Also, a small reduction in cup height was observed when the punch speed increased from 4 to 400 mm/min at 623 K. Hence, it was suggested to use high-speed deformation at elevated temperature to reduce both punch load and cycle time during the deep drawing process.
NASA Astrophysics Data System (ADS)
Pathak, N.; Butcher, C.; Worswick, M.
2016-11-01
The edge formability of ferritic-martensitic DP (dual-phase) and ferritic-bainitic CP (complex-phase) steels was evaluated using a hole expansion test for different edge conditions. Hole expansion tests involving the standard conical punch as well as a custom flat punch were performed to investigate formability when the hole is expanded out-of-plane (conical punch) and in-plane using the flat punch. A range of edge conditions were considered, in order to isolate the influence of a range of factors thought to influence edge formability. The results demonstrate that work hardening and void damage at the sheared edge govern formability, while the sheared surface quality plays a minor or secondary role. A comparison of the edge stretching limits of DP and CP steels demonstrates the advantages of a ferritic-bainitic microstructure for forming operations with severe local deformation as in a stretch-flanging operation. A comparison of a traditional DP780 steel with a CP steel of similar strength showed that the edge stretching limit of the CP steel was three times larger than that of the DP780.
Diarra, Harona; Mazel, Vincent; Busignies, Virginie; Tchoreloff, Pierre
2015-09-30
Finite elements method was used to study the influence of tablet thickness and punch curvature on the density distribution inside convex faced (CF) tablets. The modeling of the process was conducted on 2 pharmaceutical excipients (anhydrous calcium phosphate and microcrystalline cellulose) by using Drucker-Prager Cap model in Abaqus(®) software. The parameters of the model were obtained from experimental tests. Several punch shapes based on industrial standards were used. A flat-faced (FF) punch and 3 convex faced (CF) punches (8R11, 8R8 and 8R6) with a diameter of 8mm were chosen. Different tablet thicknesses were studied at a constant compression force. The simulation of the compaction of CF tablets with increasing thicknesses showed an important change on the density distribution inside the tablet. For smaller thicknesses, low density zones are located toward the center. The density is not uniform inside CF tablets and the center of the 2 faces appears with low density whereas the distribution inside FF tablets is almost independent of the tablet thickness. These results showed that FF and CF tablets, even obtained at the same compression force, do not have the same density at the center of the compact. As a consequence differences in tensile strength, as measured by diametral compression, are expected. This was confirmed by experimental tests. Copyright © 2015 Elsevier B.V. All rights reserved.
Effect of G-Coat Plus on the mechanical properties of glass-ionomer cements.
Bagheri, R; Taha, N A; Azar, M R; Burrow, M F
2013-12-01
Although various mechanical properties of tooth-coloured materials have been described, little data have been published on the effect of ageing and G-Coat Plus on the hardness and strength of the glass-ionomer cements (GICs). Specimens were prepared from one polyacid-modified resin composite (PAMRC; Freedom, SDI), one resin-modified glass-ionomer cement; (RM-GIC; Fuji II LC, GC), and one conventional glass-ionomer cement; (GIC; Fuji IX, GC). GIC and RM-GIC were tested both with and without applying G-Coat Plus (GC). Specimens were conditioned in 37 °C distilled water for either 24 hours, four and eight weeks. Half the specimens were subjected to a shear punch test using a universal testing machine; the remaining half was subjected to Vickers Hardness test. Data analysis showed that the hardness and shear punch values were material dependent. The hardness and shear punch of the PAMRC was the highest and GIC the lowest. Applying the G-Coat Plus was associated with a significant decrease in the hardness of the materials but increase in the shear punch strength after four and eight weeks. The mechanical properties of the restorative materials were affected by applying G-Coat Plus and distilled water immersion over time. The PAMRC was significantly stronger and harder than the RM-GIC or GIC. © 2013 Australian Dental Association.
Strength and Power Qualities Are Highly Associated With Punching Impact in Elite Amateur Boxers.
Loturco, Irineu; Nakamura, Fabio Y; Artioli, Guilherme G; Kobal, Ronaldo; Kitamura, Katia; Cal Abad, Cesar C; Cruz, Igor F; Romano, Felipe; Pereira, Lucas A; Franchini, Emerson
2016-01-01
This study investigated the relationship between punching impact and selected strength and power variables in 15 amateur boxers from the Brazilian National Team (9 men and 6 women). Punching impact was assessed in the following conditions: 3 jabs starting from the standardized position, 3 crosses starting from the standardized position, 3 jabs starting from a self-selected position, and 3 crosses starting from a self-selected position. For punching tests, a force platform (1.02 × 0.76 m) covered by a body shield was mounted on the wall at a height of 1 m, perpendicular to the floor. The selected strength and power variables were vertical jump height (in squat jump and countermovement jump), mean propulsive power in the jump squat, bench press (BP), and bench throw, maximum isometric force in squat and BP, and rate of force development in the squat and BP. Sex and position main effects were observed, with higher impact for males compared with females (p ≤ 0.05) and the self-selected distance resulting in higher impact in the jab technique compared with the fixed distance (p ≤ 0.05). Finally, the correlations between strength/power variables and punching impact indices ranged between 0.67 and 0.85. Because of the strong associations between punching impact and strength/power variables (e.g., lower limb muscle power), this study provides important information for coaches to specifically design better training strategies to improve punching impact.
Hernández-Ibáñez, C; Blazquez-Sánchez, N; Aguilar-Bernier, M; Fúnez-Liébana, R; Rivas-Ruiz, F; de Troya-Martín, M
Incisional biopsy may not always provide a correct classification of histologic subtypes of basal cell carcinoma (BCC). High-frequency ultrasound (HFUS) imaging of the skin is useful for the diagnosis and management of this tumor. The main aim of this study was to compare the diagnostic value of HFUS compared with punch biopsy for the correct classification of histologic subtypes of primary BCC. We also analyzed the influence of tumor size and histologic subtype (single subtype vs. mixed) on the diagnostic yield of HFUS and punch biopsy. Retrospective observational study of primary BCCs treated by the Dermatology Department of Hospital Costa del Sol in Marbella, Spain, between october 2013 and may 2014. Surgical excision was preceded by HFUS imaging (Dermascan C © , 20-MHz linear probe) and a punch biopsy in all cases. We compared the overall diagnostic yield and accuracy (sensitivity, specificity, positive predictive value [PPV], and negative predictive value [NPV]) of HFUS and punch biopsy against the gold standard (excisional biopsy with serial sections) for overall and subgroup results. We studied 156 cases. The overall diagnostic yield was 73.7% for HFUS (sensitivity, 74.5%; specificity, 73%) and 79.9% for punch biopsy (sensitivity, 76%; specificity, 82%). In the subgroup analyses, HFUS had a PPV of 93.3% for superficial BCC (vs. 92% for punch biopsy). In the analysis by tumor size, HFUS achieved an overall diagnostic yield of 70.4% for tumors measuring 40mm 2 or less and 77.3% for larger tumors; the NPV was 82% in both size groups. Punch biopsy performed better in the diagnosis of small lesions (overall diagnostic yield of 86.4% for lesions ≤40mm 2 vs. 72.6% for lesions >40mm 2 ). HFUS imaging was particularly useful for ruling out infiltrating BCCs, diagnosing simple, superficial BCCs, and correctly classifying BCCs larger than 40mm 2 . Copyright © 2016 AEDV. Publicado por Elsevier España, S.L.U. All rights reserved.
Roberts, Matthew; Ford, James L; MacLeod, Graeme S; Fell, John T; Smith, George W; Rowe, Philip H; Dyas, A Mark
2004-07-01
The sticking of a model ibuprofen-lactose formulation with respect to compaction force, punch tip geometry and punch tip embossment was assessed. Compaction was performed at 10, 25 or 40 kN using an instrumented single-punch tablet press. Three sets of 'normal' concave punches were used to evaluate the influence of punch curvature and diameter. The punches were 10, 11 and 12 mm in diameter, respectively. The 10-mm punch was embossed with a letter 'A' logo to assess the influence of an embossment on sticking. Flat-faced punches (12.5 mm) were used for comparison with the concave tooling. Surface profiles (Taylor Hobson Talysurf 120) of the upper punch faces were obtained to evaluate the surface quality of the tooling used. Following compaction, ibuprofen attached to the upper punch face was quantified by spectroscopy. Increasing punch curvature from flat-faced punches to concave decreased sticking. Altering punch diameter of the concave punches had no effect on sticking when expressed as microg mm(-2). The embossed letter 'A' logo increased sticking considerably owing to the probable concentration of shear stresses at the lateral faces of the embossed logo.
Deformation and fracture of cross-linked polymer gels
NASA Astrophysics Data System (ADS)
Lin, Wei-Chun
Because soft materials, particularly polymer gels, are playing a greater role in industrial and biotechnological applications today, the exploration of their mechanical behavior over a range of deformations is becoming more relevant in our daily lives. Understanding these properties is therefore necessary as a means to predict their response for specific applications. To address these concerns, this dissertation presents a set of analytic tools based on flat punch probe indentation tests to predict the response of polymer gels from a mechanical perspective over a large range of stresses and at failure. At small strains, a novel technique is developed to determine the transport properties of gels based on their measured mechanical behavior. Assuming that a polymer gel behaves in a similar manner as a porous structure, the differentiation of solvent flow from viscoelasticity of a gel network is shown to be possible utilizing a flat, circular punch and a flat, rectangular punch under oscillatory conditions. Use of the technique is demonstrated with a poly(N-isopropyl acrylamide) (pNIPAM) hydrogel. Our results indicate that solvent flow is inhibited at temperatures above the critical solution temperature of 35°C. At high stresses and fracture, the flat probe punch indentation geometry is used to understand how the structure and geometry of silicone based gels affect their mechanical properties. A delayed failure response of the gels is observed and the modes of failure are found to be dependent on the geometry of the system. The addition of a sol fraction in these gels was found to toughen the network and play an important role at these large deformations. Potential mechanisms of fracture resistance are discussed, as is the effect of geometric confinement as it relates to large scale deformation and fracture. These results lay the groundwork for understanding the mechanical response of other highly, deformable material systems utilizing this particular geometry.
NASA Astrophysics Data System (ADS)
Nemani, Ravi Dakshina Murthy; Rao, M. V. S.; Grandhe, Veera Venkata Satya Naranyana
2016-09-01
The present work is an effort to quantify the punching shear load resistance effect on two way simply supported slab specimens with replacement of cement by Ground Granulated Blast Furnace Slag (GGBS) with different edge conditions at various replacement levels and evaluate its efficiency. GGBS replacement has emerged as a major alternative to conventional concrete and has rapidly drawn the concrete industry attention due to its cement savings, cost savings, environmental and socio-economic benefits. The two way slab specimens were subjected to punching shear load by in house fabricated apparatus. The slab specimens were cast using M30 grade concrete with HYSD bars. The cement was partially replaced with GGBS at different percentages i.e., 0 to 30 % at regular intervals of 10 %. The test results indicate that the two way slab specimens with partial replacement of cement by GGBS exhibit high resistance against punching shear when compared with conventional concretes slab specimens.
Biomechanics of head injury in olympic taekwondo and boxing.
Fife, G P; O'Sullivan, D; Pieter, W
2013-12-01
The purpose was to examine differences between taekwondo kicks and boxing punches in resultant linear head acceleration (RLA), head injury criterion (HIC15), peak head velocity, and peak foot and fist velocities. Data from two existing publications on boxing punches and taekwondo kicks were compared. For taekwondo head impacts a Hybrid II Crash Dummy (Hybrid II) head was instrumented with a tri-axial accelerometer mounted inside the Hybrid II head. The Hybrid II was fixed to a height-adjustable frame and fitted with a protective taekwondo helmet. For boxing testing, a Hybrid III Crash Dummy head was instrumented with an array of tri-axial accelerometers mounted at the head centre of gravity. Differences in RLA between the roundhouse kick (130.11±51.67 g) and hook punch (71.23±32.19 g, d = 1.39) and in HIC15 (clench axe kick: 162.63±104.10; uppercut: 24.10±12.54, d = 2.29) were observed. Taekwondo kicks demonstrated significantly larger magnitudes than boxing punches for both RLA and HIC.
Punch Card Programmable Microfluidics
Korir, George; Prakash, Manu
2015-01-01
Small volume fluid handling in single and multiphase microfluidics provides a promising strategy for efficient bio-chemical assays, low-cost point-of-care diagnostics and new approaches to scientific discoveries. However multiple barriers exist towards low-cost field deployment of programmable microfluidics. Incorporating multiple pumps, mixers and discrete valve based control of nanoliter fluids and droplets in an integrated, programmable manner without additional required external components has remained elusive. Combining the idea of punch card programming with arbitrary fluid control, here we describe a self-contained, hand-crank powered, multiplex and robust programmable microfluidic platform. A paper tape encodes information as a series of punched holes. A mechanical reader/actuator reads these paper tapes and correspondingly executes operations onto a microfluidic chip coupled to the platform in a plug-and-play fashion. Enabled by the complexity of codes that can be represented by a series of holes in punched paper tapes, we demonstrate independent control of 15 on-chip pumps with enhanced mixing, normally-closed valves and a novel on-demand impact-based droplet generator. We demonstrate robustness of operation by encoding a string of characters representing the word “PUNCHCARD MICROFLUIDICS” using the droplet generator. Multiplexing is demonstrated by implementing an example colorimetric water quality assays for pH, ammonia, nitrite and nitrate content in different water samples. With its portable and robust design, low cost and ease-of-use, we envision punch card programmable microfluidics will bring complex control of microfluidic chips into field-based applications in low-resource settings and in the hands of children around the world. PMID:25738834
Punch card programmable microfluidics.
Korir, George; Prakash, Manu
2015-01-01
Small volume fluid handling in single and multiphase microfluidics provides a promising strategy for efficient bio-chemical assays, low-cost point-of-care diagnostics and new approaches to scientific discoveries. However multiple barriers exist towards low-cost field deployment of programmable microfluidics. Incorporating multiple pumps, mixers and discrete valve based control of nanoliter fluids and droplets in an integrated, programmable manner without additional required external components has remained elusive. Combining the idea of punch card programming with arbitrary fluid control, here we describe a self-contained, hand-crank powered, multiplex and robust programmable microfluidic platform. A paper tape encodes information as a series of punched holes. A mechanical reader/actuator reads these paper tapes and correspondingly executes operations onto a microfluidic chip coupled to the platform in a plug-and-play fashion. Enabled by the complexity of codes that can be represented by a series of holes in punched paper tapes, we demonstrate independent control of 15 on-chip pumps with enhanced mixing, normally-closed valves and a novel on-demand impact-based droplet generator. We demonstrate robustness of operation by encoding a string of characters representing the word "PUNCHCARD MICROFLUIDICS" using the droplet generator. Multiplexing is demonstrated by implementing an example colorimetric water quality assays for pH, ammonia, nitrite and nitrate content in different water samples. With its portable and robust design, low cost and ease-of-use, we envision punch card programmable microfluidics will bring complex control of microfluidic chips into field-based applications in low-resource settings and in the hands of children around the world.
NASA Astrophysics Data System (ADS)
Kumar, Pradeep; Dutta, B. K.; Chattopadhyay, J.
2017-04-01
The miniaturized specimens are used to determine mechanical properties of the materials, such as yield stress, ultimate stress, fracture toughness etc. Use of such specimens is essential whenever limited quantity of material is available for testing, such as aged/irradiated materials. The miniaturized small punch test (SPT) is a technique which is widely used to determine change in mechanical properties of the materials. Various empirical correlations are proposed in the literature to determine the value of fracture toughness (JIC) using this technique. bi-axial fracture strain is determined using SPT tests. This parameter is then used to determine JIC using available empirical correlations. The correlations between JIC and biaxial fracture strain quoted in the literature are based on experimental data acquired for large number of materials. There are number of such correlations available in the literature, which are generally not in agreement with each other. In the present work, an attempt has been made to determine the correlation between biaxial fracture strain (εqf) and crack initiation toughness (Ji) numerically. About one hundred materials are digitally generated by varying yield stress, ultimate stress, hardening coefficient and Gurson parameters. Such set of each material is then used to analyze a SPT specimen and a standard TPB specimen. Analysis of SPT specimen generated biaxial fracture strain (εqf) and analysis of TPB specimen generated value of Ji. A graph is then plotted between these two parameters for all the digitally generated materials. The best fit straight line determines the correlation. It has been also observed that it is possible to have variation in Ji for the same value of biaxial fracture strain (εqf) within a limit. Such variation in the value of Ji has been also ascertained using the graph. Experimental SPT data acquired earlier for three materials were then used to get Ji by using newly developed correlation. A reasonable comparison of calculated Ji with the values quoted in literature confirmed usefulness of the correlation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ellen M. Rabenberg; Brian J. Jaques; Bulent H. Sencer
The mechanical properties of AISI 304 stainless steel irradiated for over a decade in the Experimental Breeder Reactor (EBR-II) were measured using miniature mechanical testing methods. The shear punch method was used to evaluate the shear strengths of the neutron-irradiated steel and a correlation factor was empirically determined to predict its tensile strength. The strength of the stainless steel slightly decreased with increasing irradiation temperature, and significantly increased with increasing dose until it saturated above approximately 5 dpa. Ferromagnetic measurements were used to observe and deduce the effects of the stress-induced austenite to martensite transformation as a result of shearmore » punch testing.« less
21 CFR 882.4750 - Skull punch.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Skull punch. 882.4750 Section 882.4750 Food and... NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4750 Skull punch. (a) Identification. A skull punch is a device used to punch holes through a patient's skull to allow fixation of cranioplasty plates or...
Bonilla, Alfonso; Magri, Carlos; Juan, Eulalia
To compare the punch technique and linear incision with soft tissue reduction for the placement of auditory osseointegrated implants (AOI) and analyze results of osseointegration obtained with the punch technique as measured with the Implant Stability Quotient (ISQ). Case review of 34 patients who received auditory osseointegrated implants between January 2010 and July 2015 and were divided into two groups according to the surgical technique: 18 with the punch technique (PT) and 16 with the linear incision technique (LI). Minimum follow-up was four months (mean: 24 months; range 4-64 months). Included in the analysis were patient profiles and records of the demographic data, surgical indications, surgical technique, implant placement, surgical time, intraoperative complications, as well as postsurgical complications (Holgers classification) and implant stability quotients (ISQ). Use of larger abutments was significantly greater in the PT group (PT, 10mm; LI, 6mm, p<0.001). The PT technique resulted in a shorter procedure than the LI (PT, 20min; LI, 45min, p<0.001). Holgers classification scores identified significantly fewer skin complications one week after surgery for the PT group; however, only small differences were seen between the two groups at the one- and three-month control visits. As shown for our cohort, the punch technique for surgical placement of AOI is faster and presents fewer immediate postoperative complications when compared to the linear incision technique. The clinical application of the ISQ is a useful, easy method to demonstrate the status of osseointegration and, thus, the stability of the device. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. All rights reserved.
Gamlen, Michael John Desmond; Martini, Luigi G; Al Obaidy, Kais G
2015-01-01
The repeated compaction of Avicel PH101, dicalcium phosphate dihydrate (DCP) powder, 50:50 DCP/Avicel PH101 and Starch 1500 was studied using an instrumented laboratory tablet press which measures upper punch force, punch displacement and ejection force and operates using a V-shaped compression profile. The measurement of work compaction was demonstrated, and the test materials were ranked in order of compaction behaviour Avicel PH101 > DCP/Avicel PH101 > Starch > DCP. The behaviour of the DCP/Avicel PH101 mixture was distinctly non-linear compared with the pure components. Repeated compaction and precompression had no effect on the tensile fracture strength of Avicel PH101 tablets, although small effects on friability and disintegration time were seen. Repeated compaction and precompression reduced the tensile strength and the increased disintegration time of the DCP tablets, but improved the strength and friability of Starch 1500 tablets. Based on the data reported, routine laboratory measurement of tablet work of compaction may have potential as a critical quality attribute of a powder blend for compression. The instrumented press was suitable for student use with minimal supervisor input.
Design study of the geometry of the blanking tool to predict the burr formation of Zircaloy-4 sheet
NASA Astrophysics Data System (ADS)
Ha, Jisun; Lee, Hyungyil; Kim, Dongchul; Kim, Naksoo
2013-12-01
In this work, we investigated factors that influence burr formation for zircaloy-4 sheet used for spacer grids of nuclear fuel roads. Factors we considered are geometric factors of punch. We changed clearance and velocity in order to consider the failure parameters, and we changed shearing angle and corner radius of L-shaped punch in order to consider geometric factors of punch. First, we carried out blanking test with failure parameter of GTN model using L-shaped punch. The tendency of failure parameters and geometric factors that affect burr formation by analyzing sheared edges is investigated. Consequently, geometric factor's influencing on the burr formation is also high as failure parameters. Then, the sheared edges and burr formation with failure parameters and geometric factors is investigated using FE analysis model. As a result of analyzing sheared edges with the variables, we checked geometric factors more affect burr formation than failure parameters. To check the reliability of the FE model, the blanking force and the sheared edges obtained from experiments are compared with the computations considering heat transfer.
BIOMECHANICS OF HEAD INJURY IN OLYMPIC TAEKWONDO AND BOXING
Fife, G.P.; Pieter, W.
2013-01-01
Objective The purpose was to examine differences between taekwondo kicks and boxing punches in resultant linear head acceleration (RLA), head injury criterion (HIC15), peak head velocity, and peak foot and fist velocities. Data from two existing publications on boxing punches and taekwondo kicks were compared. Methods For taekwondo head impacts a Hybrid II Crash Dummy (Hybrid II) head was instrumented with a tri-axial accelerometer mounted inside the Hybrid II head. The Hybrid II was fixed to a height-adjustable frame and fitted with a protective taekwondo helmet. For boxing testing, a Hybrid III Crash Dummy head was instrumented with an array of tri-axial accelerometers mounted at the head centre of gravity. Results Differences in RLA between the roundhouse kick (130.11±51.67 g) and hook punch (71.23±32.19 g, d = 1.39) and in HIC15 (clench axe kick: 162.63±104.10; uppercut: 24.10±12.54, d = 2.29) were observed. Conclusions Taekwondo kicks demonstrated significantly larger magnitudes than boxing punches for both RLA and HIC. PMID:24744497
NASA Astrophysics Data System (ADS)
Sigvant, M.; Falk, J.; Pilthammar, J.
2017-09-01
Dual-Phase (DP) steels are today used in the automotive industry due to its large strength to weight ratio. However, the high strength of DP-steel does have a negative impact on the general formability in sheet metal forming. Unfavourable process conditions in the press shop will, on top of this, reduce the formability of DP-steels even more. This paper addresses the problem of edge fracture in stretch flanges in sheet metal parts made of DP-steel. The experimental part involves tests of ten different DP590 and DP780 steel grades with three different shear cut qualities. The influence on the fracture strain of the sample orientation of the shear cut are also studied by facing the burr away or towards the punch and testing samples with the cut edge parallel with the rolling direction and the transverse direction. The strains are measured with an ARAMIS system in each test, together with punch displacement and punch force. All tests are then simulated with AutoFormplus R7 and the results from these simulations are compared with the experimental results in order to find the appropriate failure strain for each combination of supplier, coating, thickness and shear cut quality.
Stress concentration in periodically rough Hertzian contact: Hertz to soft-flat-punch transition
Raphaël, E.; Léger, L.; Restagno, F.; Poulard, C.
2016-01-01
We report on the elastic contact between a spherical lens and a patterned substrate, composed of a hexagonal lattice of cylindrical pillars. The stress field and the size of the contact area are obtained by means of numerical methods: a superposition method of discrete pressure elements and an iterative bisection-like method. For small indentations, a transition from a Hertzian to a soft-flat-punch behaviour is observed when the surface fraction of the substrate that is covered by the pillars is increased. In particular, we present a master curve defined by two dimensionless parameters, which allows one to predict the stress at the centre of the contact region in terms of the surface fraction occupied by pillars. The transition between the limiting contact regimes, Hertzian and soft-flat-punch, is well described by a rational function. Additionally, a simple model to describe the Boussinesq–Cerruti-like contact between the lens and a single elastic pillar, which takes into account the pillar geometry and the elastic properties of the two bodies, is presented. PMID:27713659
Paul, Shubhajit; Taylor, Lisa J; Murphy, Brendan; Krzyzaniak, Joseph F; Dawson, Neil; Mullarney, Matthew P; Meenan, Paul; Sun, Changquan Calvin
2017-04-15
Punch sticking is a frequently occurring problem that challenges successful tablet manufacturing. A mechanistic understanding of the punch sticking phenomenon facilitates the design of effective strategies to solve punch sticking problems of a drug. The first step in this effort is to identify process parameters and particle properties that can profoundly affect sticking performance. This work was aimed at elucidating the key material properties and compaction parameters that influence punch sticking by statistically analyzing punch sticking data of 24 chemically diverse compounds obtained using a set of tooling with removable upper punch tip. Partial least square (PLS) analysis of the data revealed that particle surface area and tablet tensile strength are the most significant factors attributed to punch sticking. Die-wall pressure, ejection force, and take-off force also correlate with sticking, but to a lesser extent. Copyright © 2017 Elsevier B.V. All rights reserved.
Dubberke, Erik R; Mullane, Kathleen M; Gerding, Dale N; Lee, Christine H; Louie, Thomas J; Guthertz, Harriet; Jones, Courtney
2016-09-01
Background. Vancomycin-resistant Enterococcus (VRE) is a major healthcare-associated pathogen and a well known complication among transplant and immunocompromised patients. We report on stool VRE clearance in a post hoc analysis of the Phase 2 PUNCH CD study assessing a microbiota-based drug for recurrent Clostridium difficile infection (CDI). Methods. A total of 34 patients enrolled in the PUNCH CD study received 1 or 2 doses of RBX2660 (microbiota suspension). Patients were requested to voluntarily submit stool samples at baseline and at 7, 30, and 60 days and 6 months after the last administration of RBX2660. Stool samples were tested for VRE using bile esculin azide agar with 6 µg/mL vancomycin and Gram staining. Vancomycin resistance was confirmed by Etest. Results. VRE status (at least 1 test result) was available for 30 patients. All stool samples for 19 patients (63.3%, mean age 61.7 years, 68% female) tested VRE negative. Eleven patients (36.7%, mean age 75.5 years, 64% female) were VRE positive at the first test (baseline or 7-day follow-up). Of these patients, 72.7%, n = 8 converted to negative as of the last available follow-up (30 or 60 days or 6 months). Of the other 3: 1 died (follow-up data not available); 1 patient remained positive at all follow-ups; 1 patient retested positive at 6 months with negative tests during the interim. Conclusions. Although based on a small sample size, this secondary analysis demonstrated the possibility of successfully converting a high percentage of VRE-positive patients to negative in a recurrent CDI population with RBX2660.
Measurement of the hadronic background in the identification of muons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leuchs, Reinhard
1982-10-01
A 2 /times/ 2 m/sup 2/-sized prototype of the muon detector for the UA1 experiment at the pp storage ring of the European Nuclear Research Center CERN was tested in a negative pion beam with 10 GeV/c momentum. The muon detector consists of drift tubes with an optimized, simple electric field configuration. The spatial resolution of the drift tubes lies between 0.2 and 0.3 mm for perpendicular particle incidence, and decreases up to 1 mm for an incidence angle of 60/degree/. Non-linearities in the location-time relation are explainable from the shape of the electric field. The hadronic punch-through was studiedmore » in connection with the calorimeters of the UA1 experiment. This punch-through forms a strong source of background in muon identification. In the momentum range from 2 GeV/c to 10 GeV/c and an equivalent calorimeter thickness of 102 cm of iron the probability for hadronic punch-through W/sub h/ is described. W/sub h/ is taken with respect to an incident pion. By inserting additional calorimeters, each equivalent to 24.3 cm of iron, the punch-through is reduced by a factor of 1/3. Only at high particle momenta above 5 GeV/c does the information from the calorimeters make punch-through suppression possible. At lower momenta in the range of 2 to 3 GeV/c an angle cut for the tracks in the muon detector as reconstructed in two projections is very effective. This suppresses the punch-through by a factor of 20 to 50, without losing more than 5% of the muons with a momentum greater than 10 GeV/c. 36 refs., 46 figs., 5 tabs.« less
Buśko, Krzysztof; Staniak, Zbigniew; Szark-Eckardt, Mirosława; Nikolaidis, Pantelis Theodoros; Mazur-Różycka, Joanna; Łach, Patrycja; Michalski, Radosław; Gajewski, Jan; Górski, Michał
2016-01-01
The main aim of the study was to design a new system to measure punching and kicking forces as well as reaction times in combat sport athletes. In addition, the study examined whether there were any intergender differences in the force of punches thrown by boxers and kicking forces delivered by taekwondo athletes. Boxers (male, n = 13; female, n = 7) were examined for the force of single straight punches and taekwondo athletes (male, n = 14; female, n = 14) for force of single Apdolio and Dwit Chagi kicks. The punching bag was equipped with acceleration transducers and gyroscopes embedded in a cylinder covered with a layer to absorb shock as well as a set of colour signal diodes. Value of the punching bag's acceleration was used for calculating: strike force; the punching location on the bag; and time of a strike. The relative error of force calculation was 3%; the relative error in acceleration measurement was less than 1%. The force of a straight rear-hand punch was greater than the force of a lead-hand punch among male and female boxers. The force of Apdolio kick delivered with a rear leg was greater compared to a lead leg among female and male taekwondo athletes. Significant gender differences were noticed in the force in both types of kicks. In boxers, intergender differences were reported only for the force of a punch thrown with the rear hand. Based on these findings, it was concluded that the modified punching bag is a good diagnostic tool for combat sports.
Studies in Cup Drawing Behavior of Polymer Laminated Sheet Metal
NASA Astrophysics Data System (ADS)
Elnagmi, M.; Jain, M.; Bruhis, M.; Nielsen, K.
2011-08-01
Axisymmetric deep drawing behavior of a polymer laminated sheet metal (PLSM) is investigated using an axisymmetric cup drawing test. PLSMs are of interest as a replacement for painted finishes for automotive applications as they have the potential to achieve good quality long lasting and aesthetically appealing surfaces on stamped parts. However, there is limited understanding of PLSMs in automotive deep drawing situations to produce complex 3-D parts. The tests are carried out using well-controlled, laboratory-based, dual-action, servo-hydraulic forming presses under blank-holder force and punch displacement control conditions. An optical strain mapping system is used to measure the surface strains (and to construct 3D strain maps) from the film side of the deformed samples for a range of forming conditions. Deep drawing characteristics such as punch load versus punch displacement traces, strain distribution along the cup profile, flange wrinkling and fracture characteristics are experimentally assessed for stainless steel-plastic film laminated sheet materials. Also the effect of lamination pressure on wrinkling and delamination is investigated for a decorative pressure sensitive adhesive film affixed to the stainless steel sheet.
Ear wound regeneration in the African spiny mouse Acomys cahirinus
Matias Santos, Dino; Rita, Ana Martins; Casanellas, Ignasi; Brito Ova, Adélia; Araújo, Inês Maria; Power, Deborah
2016-01-01
Abstract While regeneration occurs in a number of taxonomic groups across the Metazoa, there are very few reports of regeneration in mammals, which generally respond to wounding with fibrotic scarring rather than regeneration. A recent report described skin shedding, skin regeneration and extensive ear punch closure in two rodent species, Acomys kempi and Acomys percivali. We examined these striking results by testing the capacity for regeneration of a third species, Acomys cahirinus, and found a remarkable capacity to repair full thickness circular punches in the ear pinna. Four‐millimeter‐diameter wounds closed completely in 2 months in 100% of ear punches tested. Histology showed extensive formation of elastic cartilage, adipose tissue, dermis, epidermis and abundant hair follicles in the repaired region. Furthermore, we demonstrated abundant angiogenesis and unequivocal presence of both muscle and nerve fibers in the reconstituted region; in contrast, similar wounds in C57BL/6 mice simply healed the borders of the cut by fibrotic scarring. Our results confirm the regenerative capabilities of Acomys, and suggest this model merits further attention. PMID:27499879
Review of Punching Shear Behaviour of Flat Slabs Reinforced with FRP Bars
NASA Astrophysics Data System (ADS)
Mohamed, Osama A.; Khattab, Rania
2017-10-01
Using Fibre Reinforced Polymer (FRP) bars to reinforce two-way concrete slabs can extend the service life, reduce maintenance cost and improve-life cycle cost efficiency. FRP reinforcing bars are more environmentally friendly alternatives to traditional reinforcing steel. Shear behaviour of reinforced concrete structural members is a complex phenomenon that relies on the development of internal load-carrying mechanisms, the magnitude and combination of which is still a subject of research. Many building codes and design standards provide design formulas for estimation of punching shear capacity of FRP reinforced flat slabs. Building code formulas take into account the effects of the axial stiffness of main reinforcement bars, the ratio of the perimeter of the critical section to the slab effective depth, and the slab thickness on the punching shear capacity of two-way slabs reinforced with FRP bars or grids. The goal of this paper is to compare experimental data published in the literature to the equations offered by building codes for the estimation of punching shear capacity of concrete flat slabs reinforced with FRP bars. Emphasis in this paper is on two North American codes, namely, ACI 440.1R-15 and CSA S806-12. The experimental data covered in this paper include flat slabs reinforced with GFRP, BFRP, and CFRP bars. Both ACI 440.1R-15 and CSA S806-12 are shown to be in good agreement with test results in terms of predicting the punching shear capacity.
A comparison of liver sampling techniques in dogs.
Kemp, S D; Zimmerman, K L; Panciera, D L; Monroe, W E; Leib, M S; Lanz, O I
2015-01-01
The liver sampling technique in dogs that consistently provides samples adequate for accurate histopathologic interpretation is not known. To compare histopathologic results of liver samples obtained by punch, cup, and 14 gauge needle to large wedge samples collected at necropsy. Seventy dogs undergoing necropsy. Prospective study. Liver specimens were obtained from the left lateral liver lobe with an 8 mm punch, a 5 mm cup, and a 14 gauge needle. After sample acquisition, two larger tissue samples were collected near the center of the left lateral lobe to be used as a histologic standard for comparison. Histopathologic features and numbers of portal triads in each sample were recorded. The mean number of portal triads obtained by each sampling method were 2.9 in needle samples, 3.4 in cup samples, 12 in punch samples, and 30.7 in the necropsy samples. The diagnoses in 66% of needle samples, 60% of cup samples, and 69% of punch samples were in agreement with the necropsy samples, and these proportions were not significantly different from each other. The corresponding kappa coefficients were 0.59 for needle biopsies, 0.52 for cup biopsies, and 0.62 for punch biopsies. The histopathologic interpretation of a liver sample in the dog is unlikely to vary if the liver biopsy specimen contains at least 3-12 portal triads. However, in comparison large necropsy samples, the accuracy of all tested methods was relatively low. Copyright © 2014 by the American College of Veterinary Internal Medicine.
Fahmy, Amal Ezzeldin; Farrag, Nadia Moustafa
2010-01-01
This in vitro study aimed to evaluate the gingival microleakage in class II cavities in primary molars restored with a low shrink silorane resin composite (Filtek P90) or a nanohybride composite resin (Filtek supreme XT) using three different techniques, (total bonding, closed or open sandwich techniques) lined by nano-filled resin modified glass ionomer cement RMGIC (Ketac N100). Additionally, the shear punch bond strength between the two types of composite and KNIO0 was also examined. For microleakage test, two standardized class II slot cavities were prepared in proximal surfaces of 60 sound extracted primary molars which were divided into 2 groups of 30 each according to the type of composite. Each group was subdivided into 3 groups (n = 10) according to the restorative technique used. The restored teeth were examined for microleakage after immersion in 2% methylene blue dye using stereomicroscope at 20 X. Microleakage scores among the groups were compared using Kruskal Wallis test followed by pair wise Mann Whitney U test at P < or = 0.05. Thirty disc specimens were prepared for determining the shear punch bond strength between the two composite materials and the KN100. Specimens were divided into 5 groups (n = 6) according to the adhesive protocol. The differences in mean bond strength values in MPa between groups were statistically analyzed using ANOVA followed by pair wise Tukey Post hoc test at P < or = 0. 05. Mode of failure was also evaluated for all groups. Both the silorane resin and nano-composite resin showed superior marginal seal with the total bonding technique compared to closed and open sandwich techniques. The recorded mean shear punch bond strength values showed no statistical significant difference between the two resin composites without or with their adhesive bonding systems when bonded to the nano-ionomer. All specimens showed cohesive mode of failures except for silorane resin with Adper Easy Bond Self Etch Adhesive (AEBSEA) which showed adhesive mode of failure. The best marginal seal was obtained with the total bonding technique using both resin composites. The shear punch bond strength between KN100 and the two composite materials was not affected by either of the used adhesive bonding agent.
21 CFR 882.4750 - Skull punch.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Skull punch. 882.4750 Section 882.4750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4750 Skull punch. (a) Identification. A skull punch is...
Edge crack sensitivity of lightweight materials under different load conditions
NASA Astrophysics Data System (ADS)
Tsoupis, I.; Merklein, M.
2016-11-01
This study addresses the analysis of edge crack sensitivity of DP800 steel and AA5182 aluminum alloy in dependency of punching and machining operation as well as load case of subsequent forming. The inserting of a round hole by punching with defined punch-to- die-clearance, milling and drilling is compared. Subsequent forming is performed by standardized hole expansion test and by Nakajima-tests with three different specimen geometries. Local strain distribution at the surface for Nakajima-tests is measured by optical strain measurement technique and investigated in order to evaluate local deformation before failure. Additionally, resulting hole expansion ratio λ is determined. Significant higher X as well as local strain values ε max are achieved by machined holes. This is directly coupled to higher local formability and stretchability for both materials. Furthermore, the load condition has a strong impact on the edge crack sensitivity of the material. Prior failure is observed with changing stress conditions using different specimen geometries also influencing the reachable maximum failure strain. Higher edge crack sensitivity is observed for DP800, which is in good accordance to the material properties in terms of ductility and strength. These data in dependency of the process parameter can be used for the design of automotive components.
Renner, Karl-Heinz; Manthey, Leonie
2018-01-01
Previous research has shown that humor and self-presentation are linked in several ways. With regard to individual differences, it turned out that gelotophilia (the joy of being laughed at) and katagelasticism (the joy of laughing at others) are substantially associated with the histrionic self-presentation style that is characterized by performing explicit As-If-behaviors (e.g., irony, parodying others) in everyday interactions. By contrast, gelotophobia (the fear of being laughed at) shows a negative correlation with histrionic self-presentation. In order to further contribute to the nomological network, we have explored whether the three dispositions toward ridicule and laughter as well as histrionic self-presentation are related to humor creation abilities. In doing so, we have assessed the four constructs in a study with 337 participants that also completed the Cartoon Punch line Production Test (CPPT, Köhler and Ruch, 1993, unpublished). In the CPPT, subjects were asked to generate as many funny punch lines as possible for six caption-removed cartoons. The created punch lines were then analyzed with regard to quantitative (e.g., number of punch lines) and qualitative (e.g., wittiness of the punch lines and overall wittiness of the person as evaluated by three independent raters) humor creation abilities. Results show that both gelotophilia and histrionic self-presentation were positively correlated with quantitative and qualitative humor creation abilities. By contrast, gelotophobia showed slightly negative and katagelasticism no associations with the assessed humor creation abilities. These findings especially apply to the subgroup of participants that created punch lines for each of the six cartoons and partly replicate and extend the results of a previous study by Ruch et al. (2009). Altogether, the results of our study show that individual differences in humor-related traits are associated with the quantity and quality of humorous punch lines. It is argued that behavior-related or performative humor creation tasks should be considered in addition to the CPPT in order to open up new avenues that can cross-fertilize research on individual differences in humor and self-presentation.
Renner, Karl-Heinz; Manthey, Leonie
2018-01-01
Previous research has shown that humor and self-presentation are linked in several ways. With regard to individual differences, it turned out that gelotophilia (the joy of being laughed at) and katagelasticism (the joy of laughing at others) are substantially associated with the histrionic self-presentation style that is characterized by performing explicit As-If-behaviors (e.g., irony, parodying others) in everyday interactions. By contrast, gelotophobia (the fear of being laughed at) shows a negative correlation with histrionic self-presentation. In order to further contribute to the nomological network, we have explored whether the three dispositions toward ridicule and laughter as well as histrionic self-presentation are related to humor creation abilities. In doing so, we have assessed the four constructs in a study with 337 participants that also completed the Cartoon Punch line Production Test (CPPT, Köhler and Ruch, 1993, unpublished). In the CPPT, subjects were asked to generate as many funny punch lines as possible for six caption-removed cartoons. The created punch lines were then analyzed with regard to quantitative (e.g., number of punch lines) and qualitative (e.g., wittiness of the punch lines and overall wittiness of the person as evaluated by three independent raters) humor creation abilities. Results show that both gelotophilia and histrionic self-presentation were positively correlated with quantitative and qualitative humor creation abilities. By contrast, gelotophobia showed slightly negative and katagelasticism no associations with the assessed humor creation abilities. These findings especially apply to the subgroup of participants that created punch lines for each of the six cartoons and partly replicate and extend the results of a previous study by Ruch et al. (2009). Altogether, the results of our study show that individual differences in humor-related traits are associated with the quantity and quality of humorous punch lines. It is argued that behavior-related or performative humor creation tasks should be considered in addition to the CPPT in order to open up new avenues that can cross-fertilize research on individual differences in humor and self-presentation. PMID:29487549
NASA Technical Reports Server (NTRS)
Cohen, S. C.; Morgan, R. C.
1985-01-01
A model of crustal deformation from continental collision that involves the penetration of a rigid punch into a deformable sheet is investigated. A linear viscous flow law is used to compute the magnitude and rate of change of crustal thickness, the velocity of mass points, strain rates and their principal axes, modes of deformation, areal changes, and stress. In general, a free lateral boundary reduces the magnitude of changes in crustal thickening by allowing material to more readily escape the advancing punch. The shearing that occurs diagonally in front of the punch terminates in compression or extension depending on whether the lateral boundary is fixed or free. When the ratio of the diameter of the punch to that of the sheet exceeds one-third, the deformation is insenstive to the choice of lateral boundary conditions. When the punch is rigid with sharply defined edges, deformation is concentrated near the punch corners. With non-rigid punches, shearing results in deformation being concentrated near the center of the punch. Variations with respect to linearity and nonlinearity of flow are discussed.
NASA Astrophysics Data System (ADS)
Kishimoto, H.; Ono, T.; Sakasegawa, H.; Tanigawa, H.; Kohno, Y.; Kohyama, A.
2013-09-01
Reduced activation ferritic/martensitic steels (RAFMs), such as F82H steels, have been developed as candidates of structural materials for fusion. In the design of a fusion reactor, cooling channels are built in the first wall of the blanket. One large issue is to determine how to join rectangular tubes to thin panels to fabricate the first wall. Hot Isostatic Pressing (HIPing) is a solution to solve the issue. Because of the thin HIPed walls of the channels, the specimen size for inspection of HIPed interface is limited. In the present research, Small Specimen Test Techniques (SSTT) are screened for the destructive toughness investigation technique of HIPed F82H joints. 1/3 size Charpy V-notch impact (1/3 CVN) and small punch (SP) tests are employed for the present research. The toughness of the HIPed joints is strongly affected by various surface finishing of specimens treated previous to the HIPing. In the present research, several kinds of HIPed joints were surface finished by different methods and investigated by 1/3 CVN impact test. The HIPed F82H joints had different toughness ranging from 20% to 70% of the toughness of the F82H base metal. The SP test is also available for the investigation of toughness change by the HIPing. The sensitivity of 1/3 CVN impact test against toughness change was better than the SP test, it revealed that the SP test has some limitations.
Design and finite element analysis of micro punch CNC machine modeling for medical devices
NASA Astrophysics Data System (ADS)
Pranoto, Sigiet Haryo; Mahardika, Muslim
2018-03-01
Research on micromanufacturing has been conducted. Miniaturization and weight reduction of various industrial products continue to be developed, machines with high accuracy and good quality of machining results are needed recently. This research includes design and simulation of Micro Punch CNC Machine using Abaqus with pneumatic system. This article concern of modeling simulation of punching miniplate titanium with 0.6 MPa of pressure and 500 µm of thickness. This study explaining von misses stress, safety factor and displacement analysis while the machine had the load of punching. The result gives the reaction forced of punching is 0.5 MPa on punch tip and maximum displacement is 3.237 × 10-1 mm. The safety factor is over than 12, and considered it safe for manufacturing process.
Not so secret agents: Event-related potentials to semantic roles in visual event comprehension.
Cohn, Neil; Paczynski, Martin; Kutas, Marta
2017-12-01
Research across domains has suggested that agents, the doers of actions, have a processing advantage over patients, the receivers of actions. We hypothesized that agents as "event builders" for discrete actions (e.g., throwing a ball, punching) build on cues embedded in their preparatory postures (e.g., reaching back an arm to throw or punch) that lead to (predictable) culminating actions, and that these cues afford frontloading of event structure processing. To test this hypothesis, we compared event-related brain potentials (ERPs) to averbal comic panels depicting preparatory agents (ex. reaching back an arm to punch) that cued specific actions with those to non-preparatory agents (ex. arm to the side) and patients that did not cue any specific actions. We also compared subsequent completed action panels (ex. agent punching patient) across conditions, where we expected an inverse pattern of ERPs indexing the differential costs of processing completed actions asa function of preparatory cues. Preparatory agents evoked a greater frontal positivity (600-900ms) relative to non-preparatory agents and patients, while subsequent completed actions panels following non-preparatory agents elicited a smaller frontal positivity (600-900ms). These results suggest that preparatory (vs. non-) postures may differentially impact the processing of agents and subsequent actions in real time. Copyright © 2017 Elsevier Inc. All rights reserved.
Lusk, Christopher H; Onoda, Yusuke; Kooyman, Robert; Gutiérrez-Girón, Alba
2010-04-01
*When grown in a common light environment, the leaves of shade-tolerant evergreen trees have a larger leaf mass per unit area (LMA) than their light-demanding counterparts, associated with differences in lifespan. Yet plastic responses of LMA run counter to this pattern: shade leaves have smaller LMA than sun leaves, despite often living longer. *We measured LMA and cell wall content, and conducted punch and shear tests, on sun and shade leaves of 13 rainforest evergreens of differing shade tolerance, in order to understand adaptation vs plastic responses of leaf structure and biomechanics to shade. *Species shade tolerance and leaf mechanical properties correlated better with cell wall mass per unit area than with LMA. Growth light environment had less effect on leaf mechanics than on LMA: shade leaves had, on average, 40% lower LMA than sun leaves, but differences in work-to-shear, and especially force-to-punch, were smaller. This was associated with a slightly larger cell wall fraction in shade leaves. *The persistence of shade leaves might reflect unattractiveness to herbivores because they yield smaller benefits (cell contents per area) per unit fracture force than sun leaves. In forest trees, cell wall fraction and force-to-punch are more robust correlates of species light requirements than LMA.
Science in mid-Victorian Punch.
Noakes, Richard
2002-09-01
This article examines the scientific content of the most famous comic journal of the Victorian period: Punch. Concentrating on the first three decades of the periodical (1841-1871), I show that Punch usually engaged with science that was highly topical, of consequence to the lives of its bourgeois readers, and suitable for comic interpretation. But Punch's satire of scientific topics was highly complex. It often contained allusions to non-scientific topics, and its engagement with science ranged from the utterly comic to the sharply critical. Punch prompted readers to think as well as laugh about science, and probably shaped their scientific education more than we think.
NASA Astrophysics Data System (ADS)
Kazakov, K. E.; Kurdina, S. P.
2018-04-01
We study the contact interaction between a system of rigid annular punches and a viscoelastic two-layer foundation. The upper layer is thin compared with the punch width. We study the case where the punch shapes are described by a rapidly varying functions. We use special methods for constructing the solutions, because the standard methods are inefficient.
ERIC Educational Resources Information Center
Bluemel, Dina
2007-01-01
This article describes how Viktor Schreckengost's work had been a learning experience for the students of Grant Elementary School. Viktor's most famous work, "Jazz Bowl," was the focus of the author's curriculum. Viktor created this punch bowl for Eleanor Roosevelt in the 1930s. The bowl was so popular that a series of them were produced. The…
Bonavina, Luigi; Laface, Letizia; Picozzi, Stefano; Nencioni, Marco; Siboni, Stefano; Bona, Davide; Sironi, Andrea; Sorba, Francesca; Clemente, Claudio
2010-09-01
With the development of tissue banking, a need for homogeneous methods of collection, processing, and storage of tissue has emerged. We describe the implementation of a biological bank in a high-volume, tertiary care University referral center for esophageal cancer surgery. We also propose an original punch biopsy technique of the surgical specimen. The method proved to be simple, reproducible, and not expensive. Unified standards for specimen collection are necessary to improve results of specimen-based diagnostic testing and research in surgical oncology.
Applying a punch with microridges in multistage deep drawing processes.
Lin, Bor-Tsuen; Yang, Cheng-Yu
2016-01-01
The developers of high aspect ratio components aim to minimize the processing stages in deep drawing processes. This study elucidates the application of microridge punches in multistage deep drawing processes. A microridge punch improves drawing performance, thereby reducing the number of stages required in deep forming processes. As an example, the original eight-stage deep forming process for a copper cylindrical cup with a high aspect ratio was analyzed by finite element simulation. Microridge punch designs were introduced in Stages 4 and 7 to replace the original punches. In addition, Stages 3 and 6 were eliminated. Finally, these changes were verified through experiments. The results showed that the microridge punches reduced the number of deep drawing stages yielding similar thickness difference percentages. Further, the numerical and experimental results demonstrated good consistency in the thickness distribution.
Material fatigue data obtained by card-programmed hydraulic loading system
NASA Technical Reports Server (NTRS)
Davis, W. T.
1967-01-01
Fatigue tests using load distributions from actual loading histories encountered in flight are programmed on punched electronic accounting machine cards. With this hydraulic loading system, airframe designers can apply up to 55 load levels to a test specimen.
23. NORTHEAST TO CIRCA 1875 POWER SHEAR, PUNCH, AND RIVETING ...
23. NORTHEAST TO CIRCA 1875 POWER SHEAR, PUNCH, AND RIVETING MACHINE SET UP TO DEMONSTRATE USE IN RIVETING COMPONENTS OF WHEEL ARMS FOR ELI WINDMILLS. HISTORIC DEBRIS FROM PUNCHING WORK IS VISIBLE BENEATH THE MACHINE IN THE OPERATOR'S PIT.' ON THE LEFT IS A U-SHAPED LOVEJOY FIELD PUNCH FOR USE IN INSTALLING STEEL WINDMILL/TOWER COMPONENTS. - Kregel Windmill Company Factory, 1416 Central Avenue, Nebraska City, Otoe County, NE
Smith, Shannon M.; Dworkin, Robert H.; Turk, Dennis C.; Baron, Ralf; Polydefkis, Michael; Tracey, Irene; Borsook, David; Edwards, Robert R.; Harris, Richard E.; Wager, Tor D.; Arendt-Nielsen, Lars; Burke, Laurie B.; Carr, Daniel B.; Chappell, Amy; Farrar, John T.; Freeman, Roy; Gilron, Ian; Goli, Veeraindar; Haeussler, Juergen; Jensen, Troels; Katz, Nathaniel P.; Kent, Jeffrey; Kopecky, Ernest A.; Lee, David A.; Maixner, William; Markman, John D.; McArthur, Justin C.; McDermott, Michael P.; Parvathenani, Lav; Raja, Srinivasa N.; Rappaport, Bob A.; Rice, Andrew S. C.; Rowbotham, Michael C.; Tobias, Jeffrey K.; Wasan, Ajay D.; Witter, James
2017-01-01
Valid and reliable biomarkers can play an important role in clinical trials as indicators of biological or pathogenic processes or as a signal of treatment response. Currently, there are no biomarkers for pain qualified by the US Food and Drug Administration or the European Medicines Agency for use in clinical trials. This article summarizes an Initiative on Methods, Measurement, and Pain Assessment in Clinical Trials (IMMPACT) meeting in which 3 potential biomarkers were discussed for use in the development of analgesic treatments: (1) sensory testing, (2), skin punch biopsy, and (3) brain imaging. The empirical evidence supporting the use of these tests is described within the context of the 4 categories of biomarkers: (1) diagnostic, (2) prognostic, (3) predictive, and (4) pharmacodynamic. Although sensory testing, skin punch biopsy, and brain imaging are promising tools for pain in clinical trials, additional evidence is needed to further support and standardize these tests for use as biomarkers in pain clinical trials. PMID:28254585
3. INTERIOR VIEW LOOKING SOUTH SHOWING PUNCH AND SHEAR MACHINE ...
3. INTERIOR VIEW LOOKING SOUTH SHOWING PUNCH AND SHEAR MACHINE (manufactured by Cleveland Punch and Shear Works Company, USA) - Cambria & Indiana Railroad, Blacksmith Shop, .25 miles northwest of Colver, Colver, Cambria County, PA
Tablet compression tooling - Impact of punch face edge modification.
Anbalagan, Parthiban; Heng, Paul Wan Sia; Liew, Celine Valeria
2017-05-30
The influence of punch face edge geometry modification on tablet compression and the properties of the resultant tablets produced on a rotary press were investigated. The results revealed that tablets produced from the punches with radius edge face geometry consistently displayed better physical quality; higher tensile strength and lower capping tendency. Modification of the angled edge of the bevel face to the curved edge of the radius face, enabled deeper punch penetration in the die cavity during the compression cycle, bringing about greater compact densification. Improved die fill packing increased interparticulate bond formation and helped to dissipate destructive elasticity within the compact, consequently reduced tablet expansion during the decompression phase. The positive impact of punch face edge modification was also more noticeable at a higher turret speed. The application of the precompression force along with dwell time extension amplified the tableting performance of radius edge punch face design to a greater extent when compared to bevel edge punch face design. This could be attributed to the enhanced packing efficiency at both precompression and main compression stages. Copyright © 2017 Elsevier B.V. All rights reserved.
Wiring harnesses documented by punched-card technique
NASA Technical Reports Server (NTRS)
Hicks, W. W.; Kloezeman, W. G.
1970-01-01
Cards representing a connector are punched, sorted, and then used to printout wiring documentation for that connector. When wiring changes are made, new cards are punched and the wiring documentation is reprinted to reflect the latest configuration.
Harms of cervical cancer screening in the United States and the Netherlands.
Habbema, Dik; Weinmann, Sheila; Arbyn, Marc; Kamineni, Aruna; Williams, Andrew E; M C M de Kok, Inge; van Kemenade, Folkert; Field, Terry S; van Rosmalen, Joost; Brown, Martin L
2017-03-01
We studied harms related to cervical cancer screening and management of screen-positive women in the United States (US) and the Netherlands. We utilized data from four US integrated health care systems (SEARCH), the US National Health Interview Survey, New Mexico state, the Netherlands national histopathology registry, and included studies on adverse health effects of cervical screening. We compared the number of Papanicolaou (Pap) smear tests, abnormal test results, punch biopsies, treatments, health problems (anxiety, pain, bleeding and discharge) and preterm births associated with excisional treatments. Results were age-standardized to the 2007 US population. Based on SEARCH, an estimated 36 million Pap tests were performed in 2007 for 91 million US women aged 21-65 years, leading to 2.3 million abnormal Pap tests, 1.5 million punch biopsies, 0.3 million treatments for precancerous lesions, 5 thousand preterm births and over 8 million health problems. Under the Netherlands screening practice, fewer Pap tests (58%), abnormal test results (64%), punch biopsies (75%), treatment procedures (40%), preterm births (60%) and health problems (63%) would have occurred. The SEARCH data did not differ much from other US data for 2007 or from more recent data up to 2013. Thus compared to the less intensive screening practice in the Netherlands, US practice of cervical cancer screening may have resulted in two- to threefold higher harms, while the effects on cervical cancer incidence and mortality are similar. The results are also of high relevance in making recommendations for HPV screening. Systematic collection of harms data is needed for monitoring and for better incorporation of harms in making screening recommendations. © 2016 UICC.
Mechanization of Cataloging Procedures *
Kilgour, Frederick G.
1965-01-01
The Columbia-Harvard-Yale Medical Libraries Computerization Project has put into operation its mechanized procedure for the production of catalog cards. Cards produced are in final form ready to be filed into a card catalog. Catalogers prepare copy on a worksheet from which punched cards are punched. An IBM 1401 computer processes the decklets of punched cards on magnetic tape to produce the expanded decklets of punched cards needed to print the various packs of catalog cards required to go into different catalogs. Next, the computer punches the expanded decklets of cards to operate an 870 Document Writer, which types out the catalog cards in final form. Cost of cards ready to file is 12.5 cents per card. Images PMID:14271110
A novel approach for quantitation of glucosylceramide in human dried blood spot using LC-MS/MS.
Ji, Allena Ji; Wang, Haixing; Ziso-Qejvanaj, Enida; Zheng, Kefei; Chung, Lee Lee; Foley, Timothy; Chuang, Wei-Lien; Richards, Susan; Sung, Crystal
2015-01-01
Glucosylceramide, an efficacy biomarker for Gaucher Type 1 disease, exhibits poor solubility in polar solvents and whole blood which makes it difficult to prepare a homogenous blood standard. We developed a novel method using standard addition approach by spiking a small volume of analyte solution on the surface of prespotted dried blood spot. The whole spots were punched out for subsequent extraction and LC-MS/MS analysis. The assay performance met all validation acceptance criteria. Glucosylceramide concentrations in 50 paired plasma and dry blood spot samples obtained from Gaucher Type 1 patients were tested and the results demonstrated the feasibility of using the DBS method for clinical biomarker monitoring. The new approach greatly improves assay precision and accuracy.
Undiagnosed Small Fiber Polyneuropathy: Is it a Component of Gulf War Illness?
2012-07-01
laboratory. After informed consent, a site (10 cm above the ankle ) is anesthetized and one or two 2- or 3mm diameter skin punches are removed using...of the scope of this study, the biopsy results of the youngsters anchor the lower end of the normal biopsy curve from which the multivariate
Hashemzadeh, Mohammad Reza; Mahdavi-Shahri, Nasser; Bahrami, Ahmad Reza; Kheirabadi, Masoumeh; Naseri, Fatemeh; Atighi, Mitra
2015-08-01
Rabbit ear wound repair is an accepted model for studies of tissue regeneration, leading to scar less wound repair. It is believed that a specific tissue, blastema, is responsible for such interesting capacity of tissue regeneration. To test this idea further and to elucidate the cellular events happening during the ear wound repair, we designed some controlled experiments in vitro. Small pieces of the ear were punched and washed immediately with normal saline. The tissues were then cultured in the Dulbecco's Modified Eagle(')s Medium, supplemented with fetal bovine serum in control group. As a treatment vitamin A and C was used to evaluate the differentiation potency of the tissue. These tissues were fixed, sectioned, stained, and microscopically studied. Micrographs of electron microscopy provided evidences revealing dedifferentiation of certain cells inside the punched tissues after incubation in tissue culture medium. The histological studies revealed that cells of the tissue (i) can undergo cellular proliferation, (ii) differentiate to epithelial, condrogenic, and osteogenic tissues, and (iii) regenerate the wounds. These results could be used for interpretation of the possible events happening during tissue engineering and wound repair in vitro. An important goal of this study is to create a tissue engineering and tissue banking model, so that in the future it could be used in further blastema tissue studies at different levels.
Numerical simulation of high speed incremental forming of aluminum alloy
NASA Astrophysics Data System (ADS)
Giuseppina, Ambrogio; Teresa, Citrea; Luigino, Filice; Francesco, Gagliardi
2013-12-01
In this study, an innovative process is analyzed with the aim to satisfy the industrial requirements, such as process flexibility, differentiation and customizing of products, cost reduction, minimization of execution time, sustainable production, etc. The attention is focused on incremental forming process, nowadays used in different fields such as: rapid prototyping, medical sector, architectural industry, aerospace and marine, in the production of molds and dies. Incremental forming consists in deforming only a small region of the workspace through a punch driven by a NC machine. SPIF is the considered variant of the process, in which the punch gives local deformation without dies and molds; consequently, the final product geometry can be changed by the control of an actuator without requiring a set of different tools. The drawback of this process is its slowness. The aim of this study is to assess the IF feasibility at high speeds. An experimental campaign will be performed by a CNC lathe with high speed to test process feasibility and the influence on materials formability mainly on aluminum alloys. The first results show how the material presents the same performance than in conventional speed IF and, in some cases, better material behavior due to the temperature field. An accurate numerical simulation has been performed to investigate the material behavior during the high speed process substantially confirming experimental evidence.
Effects of edaravone on a rat model of punch-drunk syndrome.
Nomoto, Jun; Kuroki, Takao; Nemoto, Masaaki; Kondo, Kosuke; Harada, Naoyuki; Nagao, Takeki
2011-01-01
Punch-drunk syndrome (PDS) refers to a pathological condition in which higher brain dysfunction occurs in a delayed fashion in boxers who have suffered repeated blows to the head. However, the underlying mechanisms remain unknown. This study attempted to elucidate the mechanism of higher brain dysfunction observed following skull vibration in two experiments involving a rat model of PDS. Experiment 1 evaluated the effects of edaravone on histological changes in the rat brain tissue after skull vibration (frequency 20 Hz, amplitude 4 mm, duration 60 minutes). The amount of free radicals formed in response to skull vibration was very small, and edaravone administration reduced the number of glial fibrillary acidic protein and advanced glycation end product-positive cells. Experiment 2 examined the time course of change in learning ability following skull vibration in Tokai High Avoider rats. The learning ability of individual rats was evaluated by the Sidman-type electric shock avoidance test 5 days after the last session of skull vibration or final anesthesia and once a month for 9 consecutive months. Delayed learning disability was not observed in rats administered edaravone immediately after skull vibration. These results suggest that free radical-induced astrocyte activation and subsequent glial scar formation contribute to the occurrence of delayed learning disabilities. Edaravone administration after skull vibration suppressed glial scar formation, thereby inhibiting the occurrence of delayed learning disabilities.
An ear punch model for studying the effect of radiation on wound healing.
Deoliveira, Divino; Jiao, Yiqun; Ross, Joel R; Corbin, Kayla; Xiao, Qizhen; Toncheva, Greta; Anderson-Evans, Colin; Yoshizumi, Terry T; Chen, Benny J; Chao, Nelson J
2011-08-01
Radiation and wound combined injury represents a major clinical challenge because of the synergistic interactions that lead to higher morbidity and mortality than either insult would produce singly. The purpose of this study was to develop a mouse ear punch model to study the physiological mechanisms underlying radiation effects on healing wounds. Surgical wounds were induced by a 2 mm surgical punch in the ear pinnae of MRL/MpJ mice. Photographs of the wounds were taken and the sizes of the ear punch wounds were quantified by image analysis. Local radiation to the ear was delivered by orthovoltage X-ray irradiator using a specially constructed jig that shields the other parts of body. Using this model, we demonstrated that local radiation to the wound area significantly delayed the healing of ear punch wounds in a dose-dependent fashion. The addition of sublethal whole body irradiation (7 Gy) further delayed the healing of ear punch wounds. These results were replicated in C57BL/6 mice; however, wound healing in MRL/MpJ mice was accelerated. These data indicate that the mouse ear punch model is a valuable model to study radiation and wound combined injury.
NASA Astrophysics Data System (ADS)
Mitsomwang, Pusit; Borrisutthekul, Rattana; Klaiw-awoot, Ken; Pattalung, Aran
2017-09-01
This research was carried out aiming to investigate the application of a tip-bottomed tool for bending an advanced ultra-high strength steel sheet. The V-die bending experiment of a dual phase steel (DP980) sheet which had a thickness of 1.6 mm was executed using a conventional bending and a tip-bottomed punches. Experimental results revealed that the springback of the bent worksheet in the case of the tip-bottomed punch was less than that of the conventional punch case. To further discuss bending characteristics, a finite element (FE) model was developed and used to simulate the bending of the worksheet. From the FE analysis, it was found that the application of the tip-bottomed punch contributed the plastic deformation to occur at the bending region. Consequently, the springback of the worksheet reduced. In addition, the width of the punch tip was found to affect the deformation at the bending region and determined the springback of the bent worksheet. Moreover, the use of the tip-bottomed punch resulted in the apparent increase of the surface hardness of the bent worksheet, compared to the bending with the conventional punch.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., or bending rolls; and hot or cold rolling mills. (ii) All pressing or punching machines, such as... presses; and plate punches. (iii) All bending machines, such as apron brakes and press brakes. (iv) All...
Acute high-dose lead exposure from beverage contaminated by traditional Mexican pottery.
Matte, T D; Proops, D; Palazuelos, E; Graef, J; Hernandez Avila, M
1994-10-15
Screening and follow-up blood lead measurements in a 7-year-old child of a US Embassy official in Mexico City revealed an increase in blood lead concentration from 1.10 to 4.60 mumol/L in less than 4 weeks. The cause was traced to fruit punch contaminated with lead leached from traditional ceramic pottery urns. Consumption of the contaminated punch at a picnic was associated with a 20% increase in blood lead concentrations among embassy staff and dependants who were tested 6 weeks after the exposure. This episode highlights the continued health risk, even from brief exposure, posed by traditional pottery in Mexico.
Lewandowski, Edward F.; Anderson, Petrus A.
1978-01-01
A portable punch and die jig includes a U-shaped jig of predetermined width having a slot of predetermined width in the base thereof extending completely across the width of the jig adapted to fit over the walls of rectangular tubes and a punch and die assembly disposed in a hole extending through the base of the jig communicating with the slot in the base of the jig for punching a hole in the walls of the rectangular tubes at precisely determined locations.
Athletic fashion, "Punch," and the creation of the new woman.
Collins, Tracy J R
2010-01-01
Between 1885-1900 "Punch" satirized the personality of the New Woman. However, virtually single-handedly it also gave a body and emancipated culture to this otherwise socially abstract personality. Using illustrations from "Punch," this essay argues that using sport specific clothing and equipment in its cartoons, "Punch" completely unintentionally created a liberating picture of women while simultaneously using its captions and border texts to make the New Woman's body signify the anxieties patriarchal culture had about her social personality and politics.
Examining the microtexture evolution in a hole-edge punched into 780 MPa grade hot-rolled steel
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shin, J.H.; Kim, M.S.
The deformation behavior in the hole-edge of 780 MPa grade hot-rolled steel during the punching process was investigated via microstructure characterization and computational simulation. Microstructure characterization was conducted to observe the edges of punched holes through the thickness direction, and electron back-scattered diffraction (EBSD) was used to analyze the heterogeneity of the deformation. Finite element analysis (FEA) that could account for a ductile fracture criterion was conducted to simulate the deformation and fracture behaviors of 780 MPa grade hot-rolled steel during the punching process. Calculation of rotation rate fields at the edges of the punched holes during the punching processmore » revealed that metastable orientations in Euler space were confined to specific orientation groups. Rotation-rate fields effectively explained the stability of the initial texture components in the hole-edge region during the punching process. A visco-plastic self-consistent (VPSC) polycrystal model was used to calculate the microtexture evolution in the hole-edge region during the punching process. FEA revealed that the heterogeneous effective strain was closely related to the heterogeneity of the Kernel average misorientation (KAM) distribution in the hole-edge region. A simulation of the deformation microtexture evolution in the hole-edge region using a VPSC model was in good agreement with the experimental results. - Highlights: •We analyzed the microstructure in a hole-edge punched in HR 780HB steel. •Rotation rate fields revealed the stability of the initial texture components. •Heterogeneous effective stain was closely related to the KAM distribution. •VPSC model successfully simulated the deformation microtexture evolution.« less
Effect of Punch Stroke on Deformation During Sheet Forming Through Finite Element
NASA Astrophysics Data System (ADS)
Akinlabi, Stephen; Akinlabi, Esther
2017-08-01
Forming is one of the traditional methods of making shapes, bends and curvature in metallic components during a fabrication process. Mechanical forming, in particular, employs the use of a punch, which is pressed against the sheet material to be deformed into a die by the application of an external force. This study reports on the finite element analysis of the effects of punch stroke on the resulting sheet deformation, which is directly a function of the structural integrity of the formed components for possible application in the automotive industry. The results show that punch stroke is directly proportional to the resulting bend angle of the formed components. It was further revealed that the developed plastic strain increases as the punch stroke increases.
Research on the innovative hybrid impact hydroforming
NASA Astrophysics Data System (ADS)
Lang, Lihui; Wang, Shaohua; Yang, Chunlei
2013-12-01
The innovative hybrid impact hydro-forming (IHF) technology is a kind of high strain rate forming technique which can be used for forming complex parts with small features, such as convex tables, bars etc. The present work investigates IHF using a numerical /experimental approach. In this paper, the theory of IHF is presented and finite element simulation was carried out by using MSC. The pressure distribution changes in the depth direction, but not in the width direction. However, the pressure is uniform everywhere in traditional hydro-forming. Using this shock wave loading conditions, forming experiments were carried out. Punching occurred as a result of combined tensile and shear stress effects. Furthermore, results show that using IHF technology, the design constraint to make precise die may be considerably reduced. The need to accurately control punch-die clearance may also be eliminated. Therefore, the research is very useful for forming complicated products.
Power estimation of martial arts movement using 3D motion capture camera
NASA Astrophysics Data System (ADS)
Azraai, Nur Zaidi; Awang Soh, Ahmad Afiq Sabqi; Mat Jafri, Mohd Zubir
2017-06-01
Motion capture camera (MOCAP) has been widely used in many areas such as biomechanics, physiology, animation, arts, etc. This project is done by approaching physics mechanics and the extended of MOCAP application through sports. Most researchers will use a force plate, but this will only can measure the force of impact, but for us, we are keen to observe the kinematics of the movement. Martial arts is one of the sports that uses more than one part of the human body. For this project, martial art `Silat' was chosen because of its wide practice in Malaysia. 2 performers have been selected, one of them has an experienced in `Silat' practice and another one have no experience at all so that we can compare the energy and force generated by the performers. Every performer will generate a punching with same posture which in this project, two types of punching move were selected. Before the measuring start, a calibration has been done so the software knows the area covered by the camera and reduce the error when analyze by using the T stick that have been pasted with a marker. A punching bag with mass 60 kg was hung on an iron bar as a target. The use of this punching bag is to determine the impact force of a performer when they punch. This punching bag also will be stuck with the optical marker so we can observe the movement after impact. 8 cameras have been used and placed with 2 cameras at every side of the wall with different angle in a rectangular room 270 ft2 and the camera covered approximately 50 ft2. We covered only a small area so less noise will be detected and make the measurement more accurate. A Marker has been pasted on the limb of the entire hand that we want to observe and measure. A passive marker used in this project has a characteristic to reflect the infrared that being generated by the camera. The infrared will reflected to the camera sensor so the marker position can be detected and show in software. The used of many cameras is to increase the precision and improve the accuracy of the marker. Performer movement was recorded and analyzed using software Cortex motion analysis where velocity and acceleration of a performer movement can be measured. With classical mechanics approach we have estimated the power and force of impact and shows that an experienced performer produces more power and force of impact is higher than the inexperienced performer.
Commentary: Tablet PCs--Lightweights with a Teaching Punch
ERIC Educational Resources Information Center
Parslow, Graham R.
2010-01-01
Tablet (or slate) computers are a group of small portable computers that have two features in common, a touch screen and wireless connectivity to the web. At the 2010 Consumer Electronics show held in January in Las Vegas, this category of product caused the greatest interest ahead of the release of the Apple iPad (www.cesweb.org). The tablet PC…
Structural Integrity of an Electron Beam Melted Titanium Alloy.
Lancaster, Robert; Davies, Gareth; Illsley, Henry; Jeffs, Spencer; Baxter, Gavin
2016-06-14
Advanced manufacturing encompasses the wide range of processes that consist of "3D printing" of metallic materials. One such method is Electron Beam Melting (EBM), a modern build technology that offers significant potential for lean manufacture and a capability to produce fully dense near-net shaped components. However, the manufacture of intricate geometries will result in variable thermal cycles and thus a transient microstructure throughout, leading to a highly textured structure. As such, successful implementation of these technologies requires a comprehensive assessment of the relationships of the key process variables, geometries, resultant microstructures and mechanical properties. The nature of this process suggests that it is often difficult to produce representative test specimens necessary to achieve a full mechanical property characterisation. Therefore, the use of small scale test techniques may be exploited, specifically the small punch (SP) test. The SP test offers a capability for sampling miniaturised test specimens from various discrete locations in a thin-walled component, allowing a full characterisation across a complex geometry. This paper provides support in working towards development and validation strategies in order for advanced manufactured components to be safely implemented into future gas turbine applications. This has been achieved by applying the SP test to a series of Ti-6Al-4V variants that have been manufactured through a variety of processing routes including EBM and investigating the structural integrity of each material and how this controls the mechanical response.
Love-type wave propagation in a pre-stressed viscoelastic medium influenced by smooth moving punch
NASA Astrophysics Data System (ADS)
Singh, A. K.; Parween, Z.; Chatterjee, M.; Chattopadhyay, A.
2015-04-01
In the present paper, a mathematical model studying the effect of smooth moving semi-infinite punch on the propagation of Love-type wave in an initially stressed viscoelastic strip is developed. The dynamic stress concentration due to the punch for the force of a constant intensity has been obtained in the closed form. Method based on Weiner-hopf technique which is indicated by Matczynski has been employed. The study manifests the significant effect of various affecting parameters viz. speed of moving punch associated with Love-type wave speed, horizontal compressive/tensile initial stress, vertical compressive/tensile initial stress, frequency parameter, and viscoelastic parameter on dynamic stress concentration due to semi-infinite punch. Moreover, some important peculiarities have been traced out and depicted by means of graphs.
FE Simulation of Ultrasonic Back Extrusion
NASA Astrophysics Data System (ADS)
Rosochowska, Malgorzata; Rosochowski, Andrzej
2007-04-01
The main benefit of using ultrasonic vibrations in metal forming arises from the reduction in the mean forming force. In order to examine mechanisms responsible for this effect FE simulations of ultrasonic back extrusion using ABAQUS/Explicit were carried out. In two analysed models, vibration of frequency of 20 kHz was imposed on the punch. In the first model, the die and the punch were defined as rigid bodies and in the second, the punch was modelled as an elastic body, this being the innovative feature of the research. The punch vibrated in a longitudinal mode. Simulations were performed for amplitude of vibrations of 8.5μm and different punch velocities for both friction and frictionless conditions. Results showed that the amplitude and the mean forming force depended on the process velocity. Further, the decrease in the mean forming force might be partly explained by the reduction in the friction force due to changes in the direction and magnitude of the frictional stress over the vibration period. A lower deflection of the elastic punch under oscillatory conditions was observed, which was an indirect evidence of the reduced forming force. It was also observed that amplitude of vibrations at the working surface of the elastic punch was smaller than the applied one.
Single maximal versus combination punch kinematics.
Piorkowski, Barry A; Lees, Adrian; Barton, Gabor J
2011-03-01
The aim of this study was to determine the influence of punch type (Jab, Cross, Lead Hook and Reverse Hook) and punch modality (Single maximal, 'In-synch' and 'Out of synch' combination) on punch speed and delivery time. Ten competition-standard volunteers performed punches with markers placed on their anatomical landmarks for 3D motion capture with an eight-camera optoelectronic system. Speed and duration between key moments were computed. There were significant differences in contact speed between punch types (F(2,18,84.87) = 105.76, p = 0.001) with Lead and Reverse Hooks developing greater speed than Jab and Cross. There were significant differences in contact speed between punch modalities (F(2,64,102.87) = 23.52, p = 0.001) with the Single maximal (M+/- SD: 9.26 +/- 2.09 m/s) higher than 'Out of synch' (7.49 +/- 2.32 m/s), 'In-synch' left (8.01 +/- 2.35 m/s) or right lead (7.97 +/- 2.53 m/s). Delivery times were significantly lower for Jab and Cross than Hook. Times were significantly lower 'In-synch' than a Single maximal or 'Out of synch' combination mode. It is concluded that a defender may have more evasion-time than previously reported. This research could be of use to performers and coaches when considering training preparations.
An ear punch model for studying the effect of radiation on wound healing
DeOLIVEIRA, DIVINO; JIAO, YIQUN; ROSS, JOEL R.; CORBIN, KAYLA; XIAO, QIZHEN; TONCHEVA, GRETA; ANDERSON-EVANS, COLIN; YOSHIZUMI, TERRY T.; CHEN, BENNY J.; CHAO, NELSON J.
2011-01-01
Purpose Radiation and wound combined injury represents a major clinical challenge because of the synergistic interactions that lead to higher morbidity and mortality than either insult would produce singly. The purpose of this study was to develop a mouse ear punch model to study the physiological mechanisms underlying radiation effects on healing wounds. Materials and methods Surgical wounds were induced by a 2 mm surgical punch in the ear pinnae of MRL/MpJ mice. Photographs of the wounds were taken and the sizes of the ear punch wounds were quantified by image analysis. Local radiation to the ear was delivered by orthovoltage X-ray irradiator using a specially constructed jig that shields the other parts of body. Results Using this model, we demonstrated that local radiation to the wound area significantly delayed the healing of ear punch wounds in a dose-dependent fashion. The addition of sublethal whole body irradiation (7 Gy) further delayed the healing of ear punch wounds. These results were replicated in C57BL/6 mice; however, wound healing in MRL/MpJ mice was accelerated. Conclusions These data indicate that the mouse ear punch model is a valuable model to study radiation and wound combined injury. PMID:21480768
Amateur boxing: activity profile of winners and losers.
Davis, Philip; Wittekind, Anna; Beneke, Ralph
2013-01-01
An activity profile of competitive 3 × 2-min novice-level amateur boxing was created based on video footage and postbout blood [La] in 32 male boxers (mean ± SD) age 19.3 ± 1.4 y, body mass 62.6 ± 4.1 kg. Winners landed 18 ± 11 more punches than losers by applying more lead-hand punches in round 1 (34.2 ± 10.9 vs 26.5 ± 9.4), total punches to the head (121.3 ± 10.2 vs 96.0 ± 9.8), and block and counterpunch combinations (2.8 ± 1.1 vs. 0.1 ± 0.2) over all 3 rounds and punching combinations (44.3 ± 6.4 vs 28.8 ± 6.7) in rounds 1 and 3 (all P < .05). In 16 boxers, peak postbout blood [La] was 11.8 ± 1.6 mmol/L irrespective of winning or losing. The results suggest that landing punches requires the ability to maintain a high frequency of attacking movements, in particular the lead-hand straight punch to the head together with punching combinations. Defensive movements must initiate a counterattack. Postbout blood [La] suggests that boxers must be able to tolerate a lactate production rate of 1.8 mmol · L-1 · min-1 and maintain skillful techniques at a sufficient activity rate.
Hansen, Niels; Kahn, Ann-Kathrin; Zeller, Daniel; Katsarava, Zaza; Sommer, Claudia; Üçeyler, Nurcan
2015-01-01
To investigate the usefulness of pain-related evoked potentials (PREP) elicited by electrical stimulation for the identification of small fiber involvement in patients with mixed fiber neuropathy (MFN). Eleven MFN patients with clinical signs of large fiber impairment and neuropathic pain and ten healthy controls underwent clinical and electrophysiological evaluation. Small fiber function, electrical conductivity and morphology were examined by quantitative sensory testing (QST), PREP, and skin punch biopsy. MFN was diagnosed following clinical and electrophysiological examination (chronic inflammatory demyelinating neuropathy: n = 6; vasculitic neuropathy: n = 3; chronic axonal neuropathy: n = 2). The majority of patients with MFN characterized their pain by descriptors that mainly represent C-fiber-mediated pain. In QST, patients displayed elevated cold, warm, mechanical, and vibration detection thresholds and cold pain thresholds indicative of MFN. PREP amplitudes in patients correlated with cold (p < 0.05) and warm detection thresholds (p < 0.05). Burning pain and the presence of par-/dysesthesias correlated negatively with PREP amplitudes (p < 0.05). PREP amplitudes correlating with cold and warm detection thresholds, burning pain, and par-/dysesthesias support employing PREP amplitudes as an additional tool in conjunction with QST for detecting small fiber impairment in patients with MFN. PMID:26696950
Low-resistance strip sensors for beam-loss event protection
NASA Astrophysics Data System (ADS)
Ullán, M.; Benítez, V.; Quirion, D.; Zabala, M.; Pellegrini, G.; Lozano, M.; Lacasta, C.; Soldevila, U.; García, C.; Fadeyev, V.; Wortman, J.; DeFilippis, J.; Shumko, M.; Grillo, A. A.; Sadrozinski, H. F.-W.
2014-11-01
AC-coupled silicon strip sensors can be damaged in case of a beam loss due to the possibility of a large charge accumulation in the bulk, developing very high voltages across the coupling capacitors which can destroy them. Punch-through structures are currently used to avoid this problem helping to evacuate the accumulated charge as large voltages are developing. Nevertheless, previous experiments, performed with laser pulses, have shown that these structures can become ineffective in relatively long strips. The large value of the implant resistance can effectively isolate the "far" end of the strip from the punch-through structure leading to large voltages. We present here our developments to fabricate low-resistance strip sensors to avoid this problem. The deposition of a conducting material in contact with the implants drastically reduces the strip resistance, assuring the effectiveness of the punch-through structures. First devices have been fabricated with this new technology. Initial results with laser tests show the expected reduction in peak voltages on the low resistivity implants. Other aspects of the sensor performance, including the signal formation, are not affected by the new technology.
Defense Automation Resources Management Manual
1988-09-01
Electronic Command Signals Programmer, Plugboard Programmers Punch, Card Punch, Paper Tape Reader, Character Reader-Generator, Time Cards Reader...Multiplexor-Shift Register Group Multiplier Panel Control, Plugboard Panel, Interconnection, Digital Computer Panel, Meter-Attenuator, Tape Recorder PC Cards...Perforator, Tape Plug-In Unit Potentiometer, Coefficient, Analog Computer Programmer, Plugboard Punch, Paper Tape Racks Reader, Time Code Reader
Assessing the anti-fungal efficiency of filters coated with zinc oxide nanoparticles
NASA Astrophysics Data System (ADS)
Decelis, Stephen; Sardella, Davide; Triganza, Thomas; Brincat, Jean-Pierre; Gatt, Ruben; Valdramidis, Vasilis P.
2017-05-01
Air filters support fungal growth, leading to generation of conidia and volatile organic compounds, causing allergies, infections and food spoilage. Filters that inhibit fungi are therefore necessary. Zinc oxide (ZnO) nanoparticles have anti-fungal properties and therefore are good candidates for inhibiting growth. Two concentrations (0.012 M and 0.12 M) were used to coat two types of filters (melt-blown and needle-punched) for three different periods (0.5, 5 and 50 min). Rhizopus stolonifer and Penicillium expansum isolated from spoiled pears were used as test organisms. Conidial suspensions of 105 to 103 spores ml-1 were prepared in Sabouraud dextrose agar at 50°C, and a modified slide-culture technique was used to test the anti-fungal properties of the filters. Penicillium expansum was the more sensitive organism, with inhibition at 0.012 M at only 0.5 min coating time on the needle-punched filter. The longer the coating time, the more effective inhibition was for both organisms. Furthermore, it was also determined that the coating process had only a slight effect on the Young's Moduli of the needle-punched filters, while the Young's Moduli of the melt-blown filters is more susceptible to the coating method. This work contributes to the assessment of the efficacy of filter coating with ZnO nanopaticles aimed at inhibiting fungal growth.
Assessing the anti-fungal efficiency of filters coated with zinc oxide nanoparticles
Decelis, Stephen; Sardella, Davide; Triganza, Thomas; Brincat, Jean-Pierre; Gatt, Ruben
2017-01-01
Air filters support fungal growth, leading to generation of conidia and volatile organic compounds, causing allergies, infections and food spoilage. Filters that inhibit fungi are therefore necessary. Zinc oxide (ZnO) nanoparticles have anti-fungal properties and therefore are good candidates for inhibiting growth. Two concentrations (0.012 M and 0.12 M) were used to coat two types of filters (melt-blown and needle-punched) for three different periods (0.5, 5 and 50 min). Rhizopus stolonifer and Penicillium expansum isolated from spoiled pears were used as test organisms. Conidial suspensions of 105 to 103 spores ml−1 were prepared in Sabouraud dextrose agar at 50°C, and a modified slide-culture technique was used to test the anti-fungal properties of the filters. Penicillium expansum was the more sensitive organism, with inhibition at 0.012 M at only 0.5 min coating time on the needle-punched filter. The longer the coating time, the more effective inhibition was for both organisms. Furthermore, it was also determined that the coating process had only a slight effect on the Young's Moduli of the needle-punched filters, while the Young's Moduli of the melt-blown filters is more susceptible to the coating method. This work contributes to the assessment of the efficacy of filter coating with ZnO nanopaticles aimed at inhibiting fungal growth. PMID:28572995
Assessing the anti-fungal efficiency of filters coated with zinc oxide nanoparticles.
Decelis, Stephen; Sardella, Davide; Triganza, Thomas; Brincat, Jean-Pierre; Gatt, Ruben; Valdramidis, Vasilis P
2017-05-01
Air filters support fungal growth, leading to generation of conidia and volatile organic compounds, causing allergies, infections and food spoilage. Filters that inhibit fungi are therefore necessary. Zinc oxide (ZnO) nanoparticles have anti-fungal properties and therefore are good candidates for inhibiting growth. Two concentrations (0.012 M and 0.12 M) were used to coat two types of filters (melt-blown and needle-punched) for three different periods (0.5, 5 and 50 min). Rhizopus stolonifer and Penicillium expansum isolated from spoiled pears were used as test organisms. Conidial suspensions of 10 5 to 10 3 spores ml -1 were prepared in Sabouraud dextrose agar at 50°C, and a modified slide-culture technique was used to test the anti-fungal properties of the filters. Penicillium expansum was the more sensitive organism, with inhibition at 0.012 M at only 0.5 min coating time on the needle-punched filter. The longer the coating time, the more effective inhibition was for both organisms. Furthermore, it was also determined that the coating process had only a slight effect on the Young's Moduli of the needle-punched filters, while the Young's Moduli of the melt-blown filters is more susceptible to the coating method. This work contributes to the assessment of the efficacy of filter coating with ZnO nanopaticles aimed at inhibiting fungal growth.
Halperin, Israel; Chapman, Dale W; Martin, David T; Abbiss, Chris
2017-03-01
Research indicates that instructing athlete's to focus on bodily movements (internal focus of attention [IFA]) may hinder performance, whereas instructing them to focus on the movement outcome (external focus of attention [EFA]) often enhances performance. Despite the importance of instructions in striking combat sports, limited research has examined the influence of IFA and EFA on performance in well-trained combat athletes. This study investigated the effects of different instructional cues on punching velocity (m · s -1 ) and normalised impact forces (N · kg -1 ) among intermediate (n = 8) and expert (n = 7) competitive boxers and kickboxers. Athletes completed three rounds of 12 maximal effort punches delivered to a punching integrator on three separate days. Day one was a familiarisation session with only control instructions provided. In the following two days athletes randomly received IFA, EFA or control instructions prior to each of the three rounds. Athletes punching with EFA were 4% faster and 5% more forceful than IFA (P < 0.05), and 2% faster and 3% more forceful than control (P < 0.05). Furthermore, experts punched 11% faster and with 13% greater force compared with intermediate athletes (P < 0.05). EFA led to a positive effect on punching performance and should be favoured over IFA and control instructions.
High-throughput sequencing of forensic genetic samples using punches of FTA cards with buccal swabs.
Kampmann, Marie-Louise; Buchard, Anders; Børsting, Claus; Morling, Niels
2016-01-01
Here, we demonstrate that punches from buccal swab samples preserved on FTA cards can be used for high-throughput DNA sequencing, also known as massively parallel sequencing (MPS). We typed 44 reference samples with the HID-Ion AmpliSeq Identity Panel using washed 1.2 mm punches from FTA cards with buccal swabs and compared the results with those obtained with DNA extracted using the EZ1 DNA Investigator Kit. Concordant profiles were obtained for all samples. Our protocol includes simple punch, wash, and PCR steps, reducing cost and hands-on time in the laboratory. Furthermore, it facilitates automation of DNA sequencing.
Campbell, Ian W
2016-07-01
During the 1640s, the Irish Franciscan theologian John Punch taught his theology students in Rome that war against Protestants was made just by their religion alone. Jesuits like Luis de Molina identified the holy war tradition in which Punch stood as a Scotist one, and insisted that the Scotists had confused the natural and supernatural spheres. Among Irishmen, Punch was unusual. The main Irish Catholic revolutionary tradition employed Jesuit and Thomist theory. They argued that the Stuarts had lost the right to rule Ireland for natural reasons, not supernatural ones; because the Stuarts were tyrants, not because they were Protestants.
Study on In-mold Punching during PPS/GF Injection Molding
NASA Astrophysics Data System (ADS)
Inuzuka, Takayuki; Fujita, Akihiro; Nakai, Asami; Hamada, Hiroyuki
The influence of the punching condition on strength and the amount of shear droop was investigated to optimize the processing condition for punching in the mold during glass fiber reinforced polyphenylenesulfide (PPS/GF) injection molding. For in-mold punching part during cooling process, the tensile strength was constant because the pressure loss by the punch did not occur. The amount of the shear droop decreased in line with the increase in delay time because the rigidity of injection molded part in the mold increased when the resin was cooled. Moreover, when the resin temperature lowered more than the glass transition temperature, the amount of the shear droop was constant because the rigidity became constant. It is necessary to begin punching when the resin temperature lowers more than the glass transition temperature after holding pressure process is completed, to secure high strength and to assume 0.05 mm or less, at which level the shear droop cannot be visually recognized. The shortest delay time for PPS/GF is 8 sec. The delay time to minimize the amount of the shear droop can be guessed by analyzing the temperature change of the resin in the mold by injection molding CAE.
Hayashi, Yoshihiro; Kosugi, Atsushi; Miura, Takahiro; Takayama, Kozo; Onuki, Yoshinori
2018-01-01
The influence of granule size on simulation parameters and residual shear stress in tablets was determined by combining the finite element method (FEM) into the design of experiments (DoE). Lactose granules were prepared using a wet granulation method with a high-shear mixer and sorted into small and large granules using sieves. To simulate the tableting process using the FEM, parameters simulating each granule were optimized using a DoE and a response surface method (RSM). The compaction behavior of each granule simulated by FEM was in reasonable agreement with the experimental findings. Higher coefficients of friction between powder and die/punch (μ) and lower by internal friction angle (α y ) were generated in the case of small granules, respectively. RSM revealed that die wall force was affected by α y . On the other hand, the pressure transmissibility rate of punches value was affected not only by the α y value, but also by μ. The FEM revealed that the residual shear stress was greater for small granules than for large granules. These results suggest that the inner structure of a tablet comprising small granules was less homogeneous than that comprising large granules. To evaluate the contribution of the simulation parameters to residual stress, these parameters were assigned to the fractional factorial design and an ANOVA was applied. The result indicated that μ was the critical factor influencing residual shear stress. This study demonstrates the importance of combining simulation and statistical analysis to gain a deeper understanding of the tableting process.
2013-01-01
Background Fabry disease is an inborn lysosomal storage disorder which is associated with small fiber neuropathy. We set out to investigate small fiber conduction in Fabry patients using pain-related evoked potentials (PREP). Methods In this case–control study we prospectively studied 76 consecutive Fabry patients for electrical small fiber conduction in correlation with small fiber function and morphology. Data were compared with healthy controls using non-parametric statistical tests. All patients underwent neurological examination and were investigated with pain and depression questionnaires. Small fiber function (quantitative sensory testing, QST), morphology (skin punch biopsy), and electrical conduction (PREP) were assessed and correlated. Patients were stratified for gender and disease severity as reflected by renal function. Results All Fabry patients (31 men, 45 women) had small fiber neuropathy. Men with Fabry disease showed impaired cold (p < 0.01) and warm perception (p < 0.05), while women did not differ from controls. Intraepidermal nerve fiber density (IENFD) was reduced at the lower leg (p < 0.001) and the back (p < 0.05) mainly of men with impaired renal function. When investigating A-delta fiber conduction with PREP, men but not women with Fabry disease had lower amplitudes upon stimulation at face (p < 0.01), hands (p < 0.05), and feet (p < 0.01) compared to controls. PREP amplitudes further decreased with advance in disease severity. PREP amplitudes and warm (p < 0.05) and cold detection thresholds (p < 0.01) at the feet correlated positively in male patients. Conclusion Small fiber conduction is impaired in men with Fabry disease and worsens with advanced disease severity. PREP are well-suited to measure A-delta fiber conduction. PMID:23705943
Howcroft, Jennifer; Fehlings, Darcy; Wright, Virginia; Zabjek, Karl; Andrysek, Jan; Biddiss, Elaine
2012-08-01
Active videogames (AVGs) have potential in terms of physical activity and therapy for children with cerebral palsy. However, the effect of social interaction on AVG play has not yet been assessed. The objective of this study is to determine if multiplayer AVG versus solo affects levels of energy expenditure and movement patterns. Fifteen children (9.77 [standard deviation (SD) 1.78] years old) with hemiplegic cerebral palsy (Gross Motor Function Classification System Level I) participated in solo and multiplayer Nintendo(®) "Wii™ Boxing" (Nintendo, Inc., Redmond, WA) AVG play while energy expenditure and punching frequency were monitored. Moderate levels of physical activity were achieved with no significant differences in energy measures during multiplayer and solo play. Dominant arm punching frequency increased during the multiplayer session from 95.75 (SD 37.93) punches/minute to 107.77 (SD 36.99) punches/minute. Conversely, hemiplegic arm punching frequency decreased from 39.05 (SD 29.57) punches/minutes to 30.73 (SD 24.74) punches/minutes during multiplayer game play. Children enjoyed multiplayer more than solo play. Opportunities to play AVGs with friends and family may translate to more frequent participation in this moderate physical activity. Conversely, increased hemiplegic limb use during solo play may have therapeutic advantages. As such, new strategies are recommended to promote use of the hemiplegic hand during multiplayer AVG play and to optimize commercial AVG systems for applications in virtual reality therapy.
Analysis of full-scale tank car shell impact tests
DOT National Transportation Integrated Search
2007-09-11
This paper describes analyses of a railroad tank car : impacted at its side by a ram car with a rigid punch. This : generalized collision, referred to as a shell impact, is examined : using nonlinear finite element analysis (FEA) and threedimensional...
Masai, Kyohei; Sasada, Shinji; Izumo, Takehiro; Taniyama, Tomoko; Nakamura, Yukiko; Chavez, Christine; Sakurai, Hiroyuki; Tsuta, Koji; Tsuchida, Takaaki
2013-10-01
Desmoplastic malignant mesothelioma (DMM) is a rare subtype of malignant pleural mesothelioma (MPM) and is often difficult to distinguish from pleural fibrosis and reactive mesothelial hyperplasia, especially if the biopsy samples are small. We performed full-thickness pleural biopsy on a lesion suspected to be DMM using an insulated-tip diathermic knife-2 (IT knife-2) during flex-rigid pleuroscopy. IT knife-2 is a novel electrosurgical device for endoscopic submucosal dissection in the early gastrointestinal cancer. It consists of a needle knife with 3 short blades at the distal end attached to an insulated ceramic tip. A 54-year-old man presenting with chest wall mass and thickened pleura, in whom a computed tomography-guided percutaneous needle aspiration had remained negative, underwent flex-rigid pleuroscopy for definitive diagnosis. While applying electric current, we used the IT knife-2 to incise the pleura in a circular shape just above the endothoracic fascia. The incised pleura was removed by forceps and examined pathologically. The microscopic examination was compatible with DMM. We discovered that pleuroscopic punch biopsy using IT knife-2 can diagnose DMM. Use of IT knife-2 during flex-rigid pleuroscopy can obtain sufficient samples from densely thickened pleura, which is difficult to diagnose with small biopsies.
Immunodiagnostic Techniques for Bacterial Infections
1981-01-01
specificity that specific immune sera (the immune response) provides. The early use of immunological diagnosis was to demonstrate circulating antibodies to...testing requirements. 4. Carefully remove punched plugs by suction. 5. Fill the central well with immune serum and the surrounding wells with test...capsulatuni Serum Actinomvcesr israeli Serum Aspergillus fumiqatus Serum Protozoan: Trvnanosoma cruzi Serum Entameaba histolvtica Serum Trichinella sviralis
He, Wei-Ming; Sun, Zhen-Kai
2016-02-08
Green leaves face two fundamental challenges (i.e., carbon fixation and stress tolerance) during their lifespan. However, the relationships between leaf production potential and leaf tolerance potential have not been explicitly tested with a broad range of plant species in the same environment. To do so, we conducted a field investigation based on 107 woody plants grown in a common garden and complementary laboratory measurements. The values, as measured by a chlorophyll meter, were significantly related to the direct measurements of chlorophyll content on a leaf area basis. Area-based chlorophyll content was positively correlated with root surface area, whole-plant biomass, leaf mass per area (LMA), and force to punch. Additionally, LMA had a positive correlation with force to punch. Shrubs had a higher leaf chlorophyll content than trees; however, shrubs and trees exhibited a similar leaf lifespan, force to punch, and LMA. These findings suggest that the production potential of leaves and their tolerance to stresses may be convergent in woody species and that the leaf production potential may differ between shrubs and trees. This study highlights the possibility that functional convergence and divergence might be linked to long-term selection pressures and genetic constraints.
He, Wei-Ming; Sun, Zhen-Kai
2016-01-01
Green leaves face two fundamental challenges (i.e., carbon fixation and stress tolerance) during their lifespan. However, the relationships between leaf production potential and leaf tolerance potential have not been explicitly tested with a broad range of plant species in the same environment. To do so, we conducted a field investigation based on 107 woody plants grown in a common garden and complementary laboratory measurements. The values, as measured by a chlorophyll meter, were significantly related to the direct measurements of chlorophyll content on a leaf area basis. Area-based chlorophyll content was positively correlated with root surface area, whole-plant biomass, leaf mass per area (LMA), and force to punch. Additionally, LMA had a positive correlation with force to punch. Shrubs had a higher leaf chlorophyll content than trees; however, shrubs and trees exhibited a similar leaf lifespan, force to punch, and LMA. These findings suggest that the production potential of leaves and their tolerance to stresses may be convergent in woody species and that the leaf production potential may differ between shrubs and trees. This study highlights the possibility that functional convergence and divergence might be linked to long-term selection pressures and genetic constraints. PMID:26854019
Deformation field heterogeneity in punch indentation
Murthy, Tejas G.; Saldana, Christopher; Hudspeth, Matthew; M'Saoubi, Rachid
2014-01-01
Plastic heterogeneity in indentation is fundamental for understanding mechanics of hardness testing and impression-based deformation processing methods. The heterogeneous deformation underlying plane-strain indentation was investigated in plastic loading of copper by a flat punch. Deformation parameters were measured, in situ, by tracking the motion of asperities in high-speed optical imaging. These measurements were coupled with multi-scale analyses of strength, microstructure and crystallographic texture in the vicinity of the indentation. Self-consistency is demonstrated in description of the deformation field using the in situ mechanics-based measurements and post-mortem materials characterization. Salient features of the punch indentation process elucidated include, among others, the presence of a dead-metal zone underneath the indenter, regions of intense strain rate (e.g. slip lines) and extent of the plastic flow field. Perhaps more intriguing are the transitions between shear-type and compression-type deformation modes over the indentation region that were quantified by the high-resolution crystallographic texture measurements. The evolution of the field concomitant to the progress of indentation is discussed and primary differences between the mechanics of indentation for a rigid perfectly plastic material and a strain-hardening material are described. PMID:24910521
NASA Astrophysics Data System (ADS)
Mishra, J. S.; Sakamoto, R.; Motojima, G.; Matsuyama, A.; Yamada, H.
2011-02-01
A low speed single barrel pellet injector, using a mechanical punch device has been developed for alternative injection in the large helical device. A pellet is injected by the combined operation of a mechanical punch and a pneumatic propellant system. The pellet shape is cylindrical, 3 mm in diameter and 3 mm in length. Using this technique the speed of the pellet can be controlled flexibly in the range of 100-450 m/s, and a higher speed can be feasible for a higher gas pressure. The injector is equipped with a guide tube selector to direct the pellet to different injection locations. Pellets are exposed to several curved parts with the curvature radii Rc = 0.8 and 0.3 m when they are transferred in guided tubes to the respective injection locations. Pellet speed variation with pressure at different pellet formation temperatures has been observed. Pellet intactness tests through these guide tubes show a variation in the intact speed limit over a range of pellet formation temperatures from 6.5 to 9.8 K. Pellet speed reduction of less than 6% has been observed after the pellet moves through the curved guide tubes.
Structural Integrity of an Electron Beam Melted Titanium Alloy
Lancaster, Robert; Davies, Gareth; Illsley, Henry; Jeffs, Spencer; Baxter, Gavin
2016-01-01
Advanced manufacturing encompasses the wide range of processes that consist of “3D printing” of metallic materials. One such method is Electron Beam Melting (EBM), a modern build technology that offers significant potential for lean manufacture and a capability to produce fully dense near-net shaped components. However, the manufacture of intricate geometries will result in variable thermal cycles and thus a transient microstructure throughout, leading to a highly textured structure. As such, successful implementation of these technologies requires a comprehensive assessment of the relationships of the key process variables, geometries, resultant microstructures and mechanical properties. The nature of this process suggests that it is often difficult to produce representative test specimens necessary to achieve a full mechanical property characterisation. Therefore, the use of small scale test techniques may be exploited, specifically the small punch (SP) test. The SP test offers a capability for sampling miniaturised test specimens from various discrete locations in a thin-walled component, allowing a full characterisation across a complex geometry. This paper provides support in working towards development and validation strategies in order for advanced manufactured components to be safely implemented into future gas turbine applications. This has been achieved by applying the SP test to a series of Ti-6Al-4V variants that have been manufactured through a variety of processing routes including EBM and investigating the structural integrity of each material and how this controls the mechanical response. PMID:28773590
EDXRF study of Indian punch-marked silver coins
NASA Astrophysics Data System (ADS)
Vijayan, V.; Rautray, T. R.; Basa, D. K.
2004-09-01
Coins are important archaeological objects that can provide valuable information regarding coin minting methodology and provenance as well as politics and economics of the time. Punch-marked coins are the oldest known numismatics used in ancient India. 23 Indian punch-marked silver coins were analysed, for the first time, by using multi-elemental non-destructive energy dispersive X-ray fluorescence (EDXRF) technique. Our study reveals that silver, copper, iron, gold and lead are the significant constituents of the Indian punch marked silver coins, with minor/trace of elements like Ti, Cr, Co, Ni, As and Y also seems to indicate the fragmentation as well as the impoverishment of the power for the regimes that had produced the studied coins.
The Efficiency of Small Bearings in Instruments of the Type Used in Aircraft
NASA Technical Reports Server (NTRS)
Norton, F H
1921-01-01
This report deals with the construction and properties of bearings and pivots for use in instruments. The static and running friction for both thrust and radial loads was determined for a number of conical pivots and cylindrical and ball bearings. The static rocking friction was also measured for several conical and ball bearings under a heavy load, especially to determine their suitability for use in N. P. L. (National Physical Laboratory) type wind tunnel balance. In constructing conical pivots and sockets it was found that the pivots should be hardened and highly polished, preferably with a revolving lap, and that the sockets should be made by punching with a hardened and polished punch. It was found that for a light load the conical pivots give less friction than any other type, and their wearing qualities when hardened are excellent. Very small ball bearings are unsatisfactory because the proportional accuracy of the balls and races is not high enough to insure smooth running. For rocking pivots under heavy loads it was found that a ball-and-socket bearing, consisting of a hemispherical socket and a sphere of smaller diameter concentric with it, with a row of small balls resting between the two, was superior to a pivot resting in a socket. It was found that vibration such as occurs in an airplane will greatly reduce the static friction of a pivot or bearing, in some cases to as little as one-twentieth of its static value.
Optimization of fruit punch using mixture design.
Kumar, S Bharath; Ravi, R; Saraswathi, G
2010-01-01
A highly acceptable dehydrated fruit punch was developed with selected fruits, namely lemon, orange, and mango, using a mixture design and optimization technique. The fruit juices were freeze dried, powdered, and used in the reconstitution studies. Fruit punches were prepared according to the experimental design combinations (total 10) based on a mixture design and then subjected to sensory evaluation for acceptability. Response surfaces of sensory attributes were also generated as a function of fruit juices. Analysis of data revealed that the fruit punch prepared using 66% of mango, 33% of orange, and 1% of lemon had highly desirable sensory scores for color (6.00), body (5.92), sweetness (5.68), and pleasantness (5.94). The aroma pattern of individual as well as combinations of fruit juices were also analyzed by electronic nose. The electronic nose could discriminate the aroma patterns of individual as well as fruit juice combinations by mixture design. The results provide information on the sensory quality of best fruit punch formulations liked by the consumer panel based on lemon, orange, and mango.
Focusing experiments in plasma coaxial railguns
NASA Astrophysics Data System (ADS)
Driga, M. D.; Cook, R. W.; Thelen, R. F.
1986-11-01
Results are reported from experiments on focusing of plasma fired from a coaxial electromagnetic gun (CEMG). The plasma used, obtained by exploding a metallic fuse at the gun breech, comprised metal vapor, metallic liquid droplets and small chunks of solid metal. An azimuthal current, and thereby an axial field, was introduced at the breech of the CEMG by a solenoid. Previous studies indicated that the field would cause vaporized metal to form into a self-stabilizing toroidal plasma. Test shots instrumented with Languir probes and pick-up coils did not reveal the presence of toroidal plasma rings. However, post-mortem of the 30 cm rail showed that only one-third of the 3 mg Al fuse metal remained in the bore. Further, a toroidal hole was punched in a diagnostic screen at the bore exit after one shot.
Thermomechanical simulations and experimental validation for high speed incremental forming
NASA Astrophysics Data System (ADS)
Ambrogio, Giuseppina; Gagliardi, Francesco; Filice, Luigino; Romero, Natalia
2016-10-01
Incremental sheet forming (ISF) consists in deforming only a small region of the workspace through a punch driven by a NC machine. The drawback of this process is its slowness. In this study, a high speed variant has been investigated from both numerical and experimental points of view. The aim has been the design of a FEM model able to perform the material behavior during the high speed process by defining a thermomechanical model. An experimental campaign has been performed by a CNC lathe with high speed to test process feasibility. The first results have shown how the material presents the same performance than in conventional speed ISF and, in some cases, better material behavior due to the temperature increment. An accurate numerical simulation has been performed to investigate the material behavior during the high speed process confirming substantially experimental evidence.
Effects of laser power density and initial grain size in laser shock punching of pure copper foil
NASA Astrophysics Data System (ADS)
Zheng, Chao; Zhang, Xiu; Zhang, Yiliang; Ji, Zhong; Luan, Yiguo; Song, Libin
2018-06-01
The effects of laser power density and initial grain size on forming quality of holes in laser shock punching process were investigated in the present study. Three different initial grain sizes as well as three levels of laser power densities were provided, and then laser shock punching experiments of T2 copper foil were conducted. Based upon the experimental results, the characteristics of shape accuracy, fracture surface morphology and microstructures of punched holes were examined. It is revealed that the initial grain size has a noticeable effect on forming quality of holes punched by laser shock. The shape accuracy of punched holes degrades with the increase of grain size. As the laser power density is enhanced, the shape accuracy can be improved except for the case in which the ratio of foil thickness to initial grain size is approximately equal to 1. Compared with the fracture surface morphology in the quasistatic loading conditions, the fracture surface after laser shock can be divided into three zones including rollover, shearing and burr. The distribution of the above three zones strongly relates with the initial grain size. When the laser power density is enhanced, the shearing depth is not increased, but even diminishes in some cases. There is no obvious change of microstructures with the enhancement of laser power density. However, while the initial grain size is close to the foil thickness, single-crystal shear deformation may occur, suggesting that the ratio of foil thickness to initial grain size has an important impact on deformation behavior of metal foil in laser shock punching process.
Petousis, Stamatios; Christidis, Panagiotis; Margioula-Siarkou, Chrysoula; Sparangis, Nikolaos; Athanasiadis, Apostolos; Kalogiannidis, Ioannis
2018-05-01
Τo estimate the discrepancy rate between colposcopy, punch biopsy histology and surgical specimen histology as well as the positive (PPV) and negative predictive value (NPV) of colposcopic diagnosis for high-grade squamous intraepithelial lesions (HGSIL). A prospective study was conducted during the period of 2012-2016. Αll cases in which surgical treatment had been applied and histopathological diagnosis of those surgical specimens was available were included. Cases in which ablation was performed and cases with incomplete data or conservative approach were excluded. Primary outcome was the agreement rate between histologic diagnosis of surgical specimen, histologic diagnosis of punch biopsy and colposcopic diagnosis according to REID Colposcopic Index. PPV and NPV of colposcopy and biopsy to diagnose HGSIL were also assessed. Τhere were 120 cases meeting our inclusion criteria, while biopsy was obtained in 104 cases. Mean age of women was 32.7 ± 9.0. Colposcopic diagnosis was CIN2 in 65 cases, CIN3 in 11 cases, CIN1 or less in 44 cases. Τhe level of agreement was fair between colposcopy-surgical specimen histology (κ value 0.443), fair between colposcopy-punch biopsy (κ value 0.34) and moderate between punch biopsy-cone specimen histology (κ value 0.443). PPV of colposcopy to detect HGSIL was 72.3%, while NPV was only 47.7%. Punch biopsy and surgical specimen histology present the highest agreement between the different diagnostic procedures. Colposcopy presented satisfying PPV for HGSIL cases, but its NPV was poor. In contrary, punch biopsy was characterized by both satisfying PPV and NPV for HGSIL cases.
Loturco, Irineu; Artioli, Guilherme Giannini; Kobal, Ronaldo; Gil, Saulo; Franchini, Emerson
2014-07-01
This study investigated the relationship between punching acceleration and selected strength and power variables in 19 professional karate athletes from the Brazilian National Team (9 men and 10 women; age, 23 ± 3 years; height, 1.71 ± 0.09 m; and body mass [BM], 67.34 ± 13.44 kg). Punching acceleration was assessed under 4 different conditions in a randomized order: (a) fixed distance aiming to attain maximum speed (FS), (b) fixed distance aiming to attain maximum impact (FI), (c) self-selected distance aiming to attain maximum speed, and (d) self-selected distance aiming to attain maximum impact. The selected strength and power variables were as follows: maximal dynamic strength in bench press and squat-machine, squat and countermovement jump height, mean propulsive power in bench throw and jump squat, and mean propulsive velocity in jump squat with 40% of BM. Upper- and lower-body power and maximal dynamic strength variables were positively correlated to punch acceleration in all conditions. Multiple regression analysis also revealed predictive variables: relative mean propulsive power in squat jump (W·kg-1), and maximal dynamic strength 1 repetition maximum in both bench press and squat-machine exercises. An impact-oriented instruction and a self-selected distance to start the movement seem to be crucial to reach the highest acceleration during punching execution. This investigation, while demonstrating strong correlations between punching acceleration and strength-power variables, also provides important information for coaches, especially for designing better training strategies to improve punching speed.
Humberstone, Clare E.; Iredale, K. Fiona; Martin, David T.; Blazevich, Anthony J.
2017-01-01
Humans commonly ascertain physical dominance through non-lethal fighting by participating in combat sports. However, the behaviours that achieve fight dominance are not fully understood. Amateur boxing competition, which is judged using the subjective “Ten Point Must-System”, provides insight into fight dominance behaviours. Notational analysis was performed on 26 elite male competitors in a national boxing championship. Behavioural (guard-drop time; movement style [stepping/bouncing time]; clinch-time; interaction-time) and technical (total punches; punches landed [%Hit]; air punches [%Air]; defence) measures were recorded. Participants reported effort required (0–100%) and perceived effect of fatigue on their own performance (5-point Likert scale) following bouts. Differences between winners and losers, and changes across the duration of the bout were examined. Winners punched more accurately than losers (greater %Hit [33% vs. 23%] and lower %Air [17% vs. 27%]) but total punches, defence and interaction-time were similar. From rounds 1–2, clinch-time and guard drops increased whilst bouncing decreased. Perceived effect of fatigue increased throughout the bout while perceived effort increased only from rounds 2–3. %Hit and movement index together in regression analysis correctly classified 85% of bout outcomes, indicating that judges (subjectively) chose winning (dominant) boxers according to punch accuracy and style, rather than assertiveness (more punches thrown). Boxers appear to use tactical strategies throughout the bout to pace their effort and minimise fatigue (increased guard drops, reduced bouncing), but these did not influence perceived dominance or bout outcome. These results show that judges use several performance indicators not including the total number of successful punches thrown to assess fight dominance and superiority between fighters. These results provide valuable information as to how experienced fight observers subjectively rate superiority and dominance during one-on-one human fighting. PMID:29287064
Dunn, Emily C; Humberstone, Clare E; Iredale, K Fiona; Martin, David T; Blazevich, Anthony J
2017-01-01
Humans commonly ascertain physical dominance through non-lethal fighting by participating in combat sports. However, the behaviours that achieve fight dominance are not fully understood. Amateur boxing competition, which is judged using the subjective "Ten Point Must-System", provides insight into fight dominance behaviours. Notational analysis was performed on 26 elite male competitors in a national boxing championship. Behavioural (guard-drop time; movement style [stepping/bouncing time]; clinch-time; interaction-time) and technical (total punches; punches landed [%Hit]; air punches [%Air]; defence) measures were recorded. Participants reported effort required (0-100%) and perceived effect of fatigue on their own performance (5-point Likert scale) following bouts. Differences between winners and losers, and changes across the duration of the bout were examined. Winners punched more accurately than losers (greater %Hit [33% vs. 23%] and lower %Air [17% vs. 27%]) but total punches, defence and interaction-time were similar. From rounds 1-2, clinch-time and guard drops increased whilst bouncing decreased. Perceived effect of fatigue increased throughout the bout while perceived effort increased only from rounds 2-3. %Hit and movement index together in regression analysis correctly classified 85% of bout outcomes, indicating that judges (subjectively) chose winning (dominant) boxers according to punch accuracy and style, rather than assertiveness (more punches thrown). Boxers appear to use tactical strategies throughout the bout to pace their effort and minimise fatigue (increased guard drops, reduced bouncing), but these did not influence perceived dominance or bout outcome. These results show that judges use several performance indicators not including the total number of successful punches thrown to assess fight dominance and superiority between fighters. These results provide valuable information as to how experienced fight observers subjectively rate superiority and dominance during one-on-one human fighting.
Punching influence on magnetic properties of the stator teeth of an induction motor
NASA Astrophysics Data System (ADS)
Kedous-Lebouc, A.; Cornut, B.; Perrier, J. C.; Manfé, Ph.; Chevalier, Th.
2003-01-01
In order to study the effects of punching of electrical steel sheets, a suitable geometrical structure able to characterize the stator teeth behavior of an induction motor is proposed and validated. The influence of the punching on a fully processed M330-65A is then characterized. A spectacular degradation of loss and B( H) curves is observed. This leads to a perceptible increase of the no-load machine current.
"One can't shake off the women": images of sport and gender in Punch, 1901-10.
Constanzo, Marilyn
2002-01-01
Examining the manner in which the popular press portrayed middle-class Edwardian women's activity in sport provides insight into the social liberation of English women. The popular middle-class British journal Punch included thousands of images of sportswomen. Despite the misogynistic satirizing of inept women, Punch's cartoons and articles depict distinct changes in women's behavior and social expectations that are linked to their increasing involvement in sport. By engaging in sport, women unconsciously challenged and permanently altered the pervasive middle-class Victorian ideology. The contents of Punch suggests that middle-class women's participation in sport, though perhaps begun in a conservative manner, completely altered and expanded their social role and changed the traditional image of womanhood.
Nordberg, Rachel C; Charoenpanich, Adisri; Vaughn, Christopher E; Griffith, Emily H; Fisher, Matthew B; Cole, Jacqueline H; Spang, Jeffrey T; Loboa, Elizabeth G
2016-10-28
The meniscus plays a crucial role in knee joint stability, load transmission, and stress distribution. Meniscal tears are the most common reported knee injuries, and the current standard treatment for meniscal deficiency is meniscal allograft transplantation. A major limitation of this approach is that meniscal allografts do not have the capacity to remodel and maintain tissue homeostasis due to a lack of cellular infiltration. The purpose of this study was to provide a new method for enhanced cellular infiltration in meniscal allografts. Twenty medial menisci were collected from cadaveric human sources and split into five experimental groups: (1) control native menisci, (2) decellularized menisci, (3) decellularized menisci seeded with human adipose-derived stem cells (hASC), (4) decellularized needle-punched menisci, and (5) decellularized needle-punched menisci seeded with hASC. All experimental allografts were decellularized using a combined method with trypsin EDTA and peracetic acid. Needle punching (1-mm spacing, 28 G microneedle) was utilized to improve porosity of the allograft. Samples were recellularized with hASC at a density of 250 k/g of tissue. After 28 days of in vitro culture, menisci were analyzed for mechanical, biochemical, and histological characteristics. Menisci maintained structural integrity and material properties (compressive equilibrium and dynamic moduli) throughout preparations. Increased DNA content was observed in the needle-punched menisci but not in the samples without needle punching. Histology confirmed these results, showing enhanced cellular infiltration in needle-punched samples. The enhanced infiltration achieved in this study could help meniscal allografts better remodel post-surgery. The integration of autologous adipose-derived stem cells could improve long-term efficacy of meniscal transplantation procedures by helping to maintain the meniscus in vivo.
NASA Astrophysics Data System (ADS)
Voss, B. M.; Pereira, M. P.; Rolfe, B. F.; Doolan, M. C.
2017-09-01
The growth in use of Advanced High Strength Steels in the automotive industry for light-weighting and safety has increased the rates of tool wear in sheet metal stamping. This is an issue that adds significant costs to production in terms of manual inspection and part refinishing. To reduce these costs, a tool condition monitoring system is required and a firm understanding of process signal variation must form the foundation for any such monitoring system. Punch force is a stamping process signal that is widely collected by industrial presses and has been linked closely to part quality and tool condition, making it an ideal candidate as a tool condition monitoring signal. In this preliminary investigation, the variation of punch force due to different lubrication conditions and progressive wear are examined. Linking specific punch force signature changes to developing lubrication and wear events is valuable for die wear and stamping condition monitoring. A series of semi-industrial channel forming trials were conducted under different lubrication regimes and progressive die wear. Punch force signatures were captured for each part and Principal Component Analysis (PCA) was applied to determine the key Principal Components of the signature data sets. These Principal Components were linked to the evolution of friction conditions over the course of the stroke for the different lubrication regimes and mechanism of galling wear. As a result, variation in punch force signatures were correlated to the current mechanism of wear dominant on the formed part; either abrasion or adhesion, and to changes in lubrication mechanism. The outcomes of this study provide important insights into punch force signature variation, that will provide a foundation for future work into the development of die wear and lubrication monitoring systems for sheet metal stamping.
Hukkanen, Esa; Häkkinen, Keijo
2017-06-01
Seven, male, national-level boxers (age, 20.3 ± 2.7 years; height, 1.80 ± 0.06 m; mass, 73.8 ± 11.1 kg) participated in this study to investigate the effects of sparring on reaction time and punch force of straight punches measured during the precompetition and competition periods. Heart rate and blood lactate concentrations were also monitored. Sparring load was chosen in accordance with the current rules: 3 × 3-minute bouts with 1-minute break in between. Reaction time of rear straight lengthened (p < 0.01) during the sparring load of the precompetition period after the third round (to 390 milliseconds) in comparison to the competition period (to 310 milliseconds). Reaction time of lead straight lengthened (p ≤ 0.05) between the first and third round during the precompetition with no differences during the competition period. Both rear and lead straight punch forces were greater at all measurement points during the precompetition compared with the competition period. Punch forces increased for both rear and lead straight between the first and third rounds with the highest forces after third round during the precompetition (rear straight, 209 kg) and competition (rear straight, 176 kg) periods. Blood lactate levels increased after every round during both periods being at its greatest after the third round (17 mmol·L during the precompetition and 13 mmol·L during the competition period). The present sparring-induced differences in reaction time and punch forces of straight punches during the precompetition compared with the competition period may be the result of different volume and intensity of training with different goals in boxing-specific and explosive strength training.
ASDIR-II. Volume I. User Manual
1975-12-01
normally the most significant part of the overall aircraft IR signature. The 4 radiance is directly dependent upon the geometric view factors , a set...tactors as punched card output in. a view factor computer run. For the view factor computer run IB49 through 53 and all IDS input A, from IDS-2 to IDS-6...may be excluded from the input string if the * program execution is requested to stop after punching the viewv factors . Inputs required for punching
Star Catalogs on Punched Cards and Magnetic Tape
NASA Technical Reports Server (NTRS)
Berbert, J. H.
1961-01-01
In connection with the calibration of the Minitrack satellite tracking stations, the Goddard Space Flight Center has had the contents of a number of star catalogs put on punched cards and magnetic tape. This report discusses the plate data reduction procedures, briefly describes the information on the punched cards and magnetic tape, and calls attention to other applications of the card and tape star catalogs. The Goddard Space Flight Center has offered to prepare duplicate catalogs for qualified organizations.
NASA Astrophysics Data System (ADS)
Popoveniuc, Stefan; Hosp, Ben
PunchScan is a precinct-read optical-scan balloting system that allows voters to take their ballot with them after scanning. This does not violate the secret ballot principle because the ballots cannot be read without secret information held by the distributed authority in charge of the election. In fact, this election authority will publish the ballots for everyone to see, allowing voters whose ballots were incorrectly omitted to complain. PunchScan vote-counting is performed in private by the election authority - who uses their secret information to decode the ballots - but is verified in public by an auditor.In this paper we describe how and why PunchScan works. We have kept most of the description at an outline level so that it may be used as a straw model of a cryptographic voting system.
Studies on the finite element simulation in sheet metal stamping processes
NASA Astrophysics Data System (ADS)
Huang, Ying
The sheet metal stamping process plays an important role in modern industry. With the ever-increasing demand for shape complexity, product quality and new materials, the traditional trial and error method for setting up a sheet metal stamping process is no longer efficient. As a result, the Finite Element Modeling (FEM) method has now been widely used. From a physical point of view, the formability and the quality of a product are influenced by several factors. The design of the product in the initial stage and the motion of the press during the production stage are two of these crucial factors. This thesis focuses on the numerical simulation for these two factors using FEM. Currently, there are a number of commercial FEM software systems available in the market. These software systems are based on an incremental FEM process that models the sheet metal stamping process in small incremental steps. Even though the incremental FEM is accurate, it is not suitable for the initial conceptual design for its needing of detailed design parameters and enormous calculation times. As a result, another type of FEM, called the inverse FEM method or one-step FEM method, has been proposed. While it is less accurate than that of the incremental method, this method requires much less computation and hence, has a great potential. However, it also faces a number of unsolved problems, which limits its application. This motivates the presented research. After the review of the basic theory of the inverse method, a new modified arc-length search method is proposed to find better initial solution. The methods to deal with the vertical walls are also discussed and presented. Then, a generalized multi-step inverse FEM method is proposed. It solves two key obstacles: the first one is to determine the initial solution of the intermediate three-dimensional configurations and the other is to control the movement of nodes so they could only slide on constraint surfaces during the search by Newton-Raphson iteration. The computer implementation of the generalized multi-step inverse FEM is also presented. By comparing to the simulation results using a commercial software system, the effectiveness of the new method is validated. Other than the product design, the punch motion (including punch speed and punch trajectory) of the stamping press also has significant effect on the formability and the quality of the product. In fact, this is one of the major reasons why hydraulic presses and/or servo presses are used for parts which demand high quality. In order to reveal the quantitative correlation between the punch motion and the part quality, the Cowper-Symonds strain rate constitutive model and the implicit dynamic incremental FEM are combined to conduct the research. The effects of the punch motion on the part quality, especially the plastic strain distribution and the potential springback, have been investigated for the deep drawing and the bending processes respectively. A qualitative relationship between the punch motion and the part quality is also derived. The reaction force of the punch motion causes the dynamic deformation of the press during the stamping, which in turn influences the part quality as well. This dynamic information, in the form of the strain signal, is an important basis for the on-line monitoring of the part quality. By using the actual force as the input to the press, the incremental FEM is needed to predict the strain of the press. The result is validated by means of experiments and can be used to assist the on-line monitoring.
Zhang, Ri-Hui; Kang, Zhi-Xin
2011-05-01
To study training effect of upper limbs and lumbar muscles in the proceed of air striking of straight punch by analyzing boxing athletes' changes of electromyogram (EMG). We measured EMG of ten women boxing athletes' upper arm biceps (contractor muscle), upper arm triceps (antagonistic muscle), forearm flexor muscle (contractor muscle), forearm extensor muscle (antagonistic muscle), and lumbar muscles by ME6000 (Mega Electronics Ltd.). The stipulated exercise was to do air striking of straight punch with loads of 2.5 kg of dumbbell in the hand until exhausted. In the proceed of exercise-induce exhausted, the descend magnitude and speed of median frequency (MF) in upper limb antagonistic muscle exceeded to contracting muscle, moreover, the work percentage showed that contractor have done a larger percentage of work than antagonistic muscle. Compared with world champion's EMG, the majority of ordinary athletes' lumbar muscles MF revealed non-drop tendency, and the work percentage showed that lumbar muscles had a very little percentage of work. After comparing the EMG test index in upper limb and lumbar muscle of average boxing athletes with that of the world champion, we find the testees lack of the training of upper limb antagonistic muscle and lumbar muscle, and more trainings aimed at these muscles need to be taken.
NASA Astrophysics Data System (ADS)
Ganesh Kumar, J.; Laha, K.; Ganesan, V.; Prasad Reddy, G. V.
2018-05-01
The small punch creep (SPC) behavior of 316LN stainless steel (SS) containing 0.07, 0.11 and 0.14 wt.% nitrogen has been investigated at 923 K. The transient and tertiary SPC deformation of 316LN SS with various nitrogen contents have been analyzed according to the equation proposed for SPC deflection, δ = δ0 + δT (1 - e^{ - κ t} ) + \\dot{δ }s t + δ3 e^{[ φ( {t - tr } )} ]. The relationships among the rate of exhaustion of transient creep ( κ), steady-state deflection rate (\\dot{δ }s) and the rate of acceleration of tertiary creep ( φ) revealed the interrelationships among the three stages of SPC curve. The first-order reaction rate theory was found to be applicable to SPC deformation throughout the transient as well as tertiary region, in all the investigated steels. The initial and final creep deflection rates were decreased, whereas time to attain steady-state deflection rate increased with the increase in nitrogen content. By increasing the nitrogen content in 316LN SS from 0.07 to 0.14 wt.%, each stage of SPC was prolonged, and consequently, the values of κ, \\dot{δ }s and φ were lowered. Using the above parameters, the master curves for both transient and tertiary SPC deflections were constructed for 316LN SS containing different nitrogen contents.
NASA Astrophysics Data System (ADS)
Ganesh Kumar, J.; Laha, K.; Ganesan, V.; Prasad Reddy, G. V.
2018-04-01
The small punch creep (SPC) behavior of 316LN stainless steel (SS) containing 0.07, 0.11 and 0.14 wt.% nitrogen has been investigated at 923 K. The transient and tertiary SPC deformation of 316LN SS with various nitrogen contents have been analyzed according to the equation proposed for SPC deflection, δ = δ0 + δT (1 - e^{ - κ t} ) + \\dot{δ }s t + δ3 e^[ φ( t - tr ) ]. The relationships among the rate of exhaustion of transient creep (κ), steady-state deflection rate (\\dot{δ }s ) and the rate of acceleration of tertiary creep (φ) revealed the interrelationships among the three stages of SPC curve. The first-order reaction rate theory was found to be applicable to SPC deformation throughout the transient as well as tertiary region, in all the investigated steels. The initial and final creep deflection rates were decreased, whereas time to attain steady-state deflection rate increased with the increase in nitrogen content. By increasing the nitrogen content in 316LN SS from 0.07 to 0.14 wt.%, each stage of SPC was prolonged, and consequently, the values of κ, \\dot{δ }s and φ were lowered. Using the above parameters, the master curves for both transient and tertiary SPC deflections were constructed for 316LN SS containing different nitrogen contents.
Ultrasonic Welding of Graphite/Thermoplastic Composite
NASA Technical Reports Server (NTRS)
Hardy, S. S.; Page, D. B.
1982-01-01
Ultrasonic welding of graphite/thermoplastic composite materials eliminates need for fasteners (which require drilling or punching, add weight, and degrade stiffness) and can be totally automated in beam fabrication and assembly jigs. Feasibility of technique has been demonstrated in laboratory tests which show that neither angular orientation nor vacuum affect weld quality.
USDA-ARS?s Scientific Manuscript database
Most current gin saw manufacturers use a 1074 steel or similar as a basis to manufacture their saw blades. The saw teeth are individually punched on the edges of the blades and then the blade goes through a heat treating process prior to use. There are indications from other industries with similar ...
Teletext Brings TV into the Computer Age.
ERIC Educational Resources Information Center
Wollman, Jane
1982-01-01
Briefly reviews two teletext services being tested in Chicago--KEYFAX and NITE-OWL--and other teletext experiments. KEYFAX offers information on news, sports, weather/travel, and leisure, which can be selected and displayed on the screen of a home television set by punching code numbers on a remote-control device. (JJD)
Influence of Punch Geometry on Process Parameters in Cold Backward Extrusion
NASA Astrophysics Data System (ADS)
Plančak, M.; Barišić, B.; Car, Z.; Movrin, D.
2011-01-01
In cold extrusion of steel tools make direct contact with the metal to be extruded. Those tools are exposed to high contact stresses which, in certain cases, may be limiting factors in applying this technology. The present paper was bound to the influence of punch head design on radial stress at the container wall in the process of cold backward extrusion. Five different punch head geometries were investigated. Radial stress on the container wall was measured by pin load cell technique. Special tooling for the experimental investigation was designed and made. Process has been analyzed also by FE method. 2D models of tools were obtained by UGS NX and for FE analysis Simufact Forming GP software was used. Obtained results (experimental and obtained by FE) were compared and analyzed. Optimal punch head geometry has been suggested.
High-speed blanking of copper alloy sheets: Material modeling and simulation
NASA Astrophysics Data System (ADS)
Husson, Ch.; Ahzi, S.; Daridon, L.
2006-08-01
To optimize the blanking process of thin copper sheets ( ≈ 1. mm thickness), it is necessary to study the influence of the process parameters such as the punch-die clearance and the wear of the punch and the die. For high stroke rates, the strain rate developed in the work-piece can be very high. Therefore, the material modeling must include the dynamic effects.For the modeling part, we propose an elastic-viscoplastic material model combined with a non-linear isotropic damage evolution law based on the theory of the continuum damage mechanics. Our proposed modeling is valid for a wide range of strain rates and temperatures. Finite Element simulations, using the commercial code ABAQUS/Explicit, of the blanking process are then conducted and the results are compared to the experimental investigations. The predicted cut edge of the blanked part and the punch-force displacement curves are discussed as function of the process parameters. The evolution of the shape errors (roll-over depth, fracture depth, shearing depth, and burr formation) as function of the punch-die clearance, the punch and the die wear, and the contact punch/die/blank-holder are presented. A discussion on the different stages of the blanking process as function of the processing parameters is given. The predicted results of the blanking dependence on strain-rate and temperature using our modeling are presented (for the plasticity and damage). The comparison our model results with the experimental ones shows a good agreement.
Evaluation of punching shear strength of flat slabs supported on rectangular columns
NASA Astrophysics Data System (ADS)
Filatov, Valery
2018-03-01
The article presents the methodology and results of an analytical study of structural parameters influence on the value of punching force for the joint of columns and flat reinforced concrete slab. This design solution is typical for monolithic reinforced concrete girderless frames, which have a wide application in the construction of high-rise buildings. As the results of earlier studies show the punching shear strength of slabs at rectangular columns can be lower than at square columns with a similar length of the control perimeter. The influence of two structural parameters on the punching strength of the plate is investigated - the ratio of the side of the column cross-section to the effective depth of slab C/d and the ratio of the sides of the rectangular column Cmax/Cmin. According to the results of the study, graphs of reduction the control perimeter depending on the structural parameters are presented for columns square and rectangular cross-sections. Comparison of results obtained by proposed approach and MC2010 simplified method are shown, that proposed approach gives a more conservative estimate of the influence of the structural parameters. A significant influence of the considered structural parameters on punching shear strength of reinforced concrete slabs is confirmed by the results of experimental studies. The results of the study confirm the necessity of taking into account the considered structural parameters when calculating the punching shear strength of flat reinforced concrete slabs and further development of code design methods.
Laker-Oketta, Miriam O; Wenger, Megan; Semeere, Aggrey; Castelnuovo, Barbara; Kambugu, Andrew; Lukande, Robert; Asirwa, F Chite; Busakhala, Naftali; Buziba, Nathan; Diero, Lameck; Wools-Kaloustian, Kara; Strother, Robert Matthew; Bwana, Mwebesa; Muyindike, Winnie; Amerson, Erin; Mbidde, Edward; Maurer, Toby; Martin, Jeffrey
2015-01-01
Fueled by HIV, sub-Saharan Africa has the highest incidence of Kaposi's sarcoma (KS) in the world. Despite this, KS diagnosis in the region is based mostly on clinical grounds. Where biopsy is available, it has traditionally been excisional and performed by surgeons, resulting in multiple appointments, follow-up visits for suture removal, and substantial costs. We hypothesized that a simpler approach - skin punch biopsy - would make histologic diagnosis more accessible. To address this, we provided training and equipment for skin punch biopsy of suspected KS to three HIV clinics in East Africa. The procedure consisted of local anesthesia followed by a disposable cylindrical punch blade to obtain specimens. Hemostasis is facilitated by Gelfoam®. Patients removed the dressing after 4 days. From 2007 to 2013, 2,799 biopsies were performed. Although originally targeted to be used by physicians, biopsies were performed predominantly by nurses (62%), followed by physicians (15%), clinical officers (12%) and technicians (11%). There were no reports of recurrent bleeding or infection. After minimal training and provision of inexpensive equipment (USD 3.06 per biopsy), HIV clinics in East Africa can integrate same-day skin punch biopsy for suspected KS. Task shifting from physician to non-physician greatly increases access. Skin punch biopsy should be part of any HIV clinic's essential procedures. This example of task shifting may also be applicable to the diagnosis of other cancers (e.g., breast) in resource-limited settings.
Mitsunaga, Erin M
2006-05-01
During the Korean War, International Business Machines (IBM) punch cards were created for every individual involved in military combat. Each card contained all pertinent personal information about the individual and was utilized to keep track of all soldiers involved. However, at present, all of the information known about these punch cards reveals only their format and their significance; there is little to no information on how these cards were created or how to interpret the information contained without the aid of the computer system used during the war. Today, it is believed there is no one available to explain this computerized system, nor do the original computers exist. This decode strategy is the result of an attempt to decipher the information on these cards through the use of all available medical and dental records for each individual examined. By cross-referencing the relevant personal information with the known format of the cards, a basic guess-and-check method was utilized. After examining hundreds of IBM punch cards, however, it has become clear that the punch card method of recording information was not infallible. In some cases, there are gaps of information on cards where there are data recorded on personal records; in others, information is punched incorrectly onto the cards, perhaps as the result of a transcription error. Taken all together, it is clear that the information contained on each individual's card should be taken solely as another form of personal documentation.
NASA Astrophysics Data System (ADS)
Müller, Simon; Weygand, Sabine M.
2018-05-01
Axisymmetric stretch forming processes of aluminium-polymer laminate foils (e.g. consisting of PA-Al-PVC layers) are analyzed numerically by finite element modeling of the multi-layer material as well as experimentally in order to identify a suitable damage initiation criterion. A simple ductile fracture criterion is proposed to predict the forming limits. The corresponding material constants are determined from tensile tests and then applied in forming simulations with different punch geometries. A comparison between the simulations and the experimental results shows that the determined failure constants are not applicable. Therefore, one forming experiment was selected and in the corresponding simulation the failure constant was fitted to its measured maximum stretch. With this approach it is possible to predict the forming limit of the laminate foil with satisfying accuracy for different punch geometries.
Surprise but not coherence: sensitivity to verbal humor in right-hemisphere patients.
Brownell, H H; Michel, D; Powelson, J; Gardner, H
1983-01-01
Verbal humor deficits were investigated in right-hemisphere-damaged patients. It was hypothesized that the appreciation of jokes presupposes two elements: sensitivity to the surprise element entailed in the punch line of a joke and apprehension of the coherence which results when the punch line has been integrated with the body of the joke. The possible dissociation between these elements was tested by asking subjects to select from four alternatives the appropriate ending to a joke. Right-hemisphere patients exhibited a selective attraction to endings which contained an element of surprise but which were not otherwise coherent with the body of the joke. This finding suggests that right-hemisphere patients have difficulty in integrating content across parts of a narrative and confirms the psychological reality of the proposed distinction between the surprise and coherence elements of humor processing.
Amplification volume reduction on DNA database samples using FTA™ Classic Cards.
Wong, Hang Yee; Lim, Eng Seng Simon; Tan-Siew, Wai Fun
2012-03-01
The DNA forensic community always strives towards improvements in aspects such as sensitivity, robustness, and efficacy balanced with cost efficiency. Therefore our laboratory decided to study the feasibility of PCR amplification volume reduction using DNA entrapped in FTA™ Classic Card and to bring cost savings to the laboratory. There were a few concerns the laboratory needed to address. First, the kinetics of the amplification reaction could be significantly altered. Second, an increase in sensitivity might affect interpretation due to increased stochastic effects even though they were pristine samples. Third, statics might cause FTA punches to jump out of its allocated well into another thus causing sample-to-sample contamination. Fourth, the size of the punches might be too small for visual inspection. Last, there would be a limit to the extent of volume reduction due to evaporation and the possible need of re-injection of samples for capillary electrophoresis. The laboratory had successfully optimized a reduced amplification volume of 10 μL for FTA samples. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Use of loading-unloading compression curves in medical device design
NASA Astrophysics Data System (ADS)
Ciornei, M. C.; Alaci, S.; Ciornei, F. C.; Romanu, I. C.
2017-08-01
The paper presents a method and experimental results regarding mechanical testing of soft materials. In order to characterize the mechanical behaviour of technological materials used in prosthesis, a large number of material constants are required, as well as the comparison to the original. The present paper proposes as methodology the comparison between compression loading-unloading curves corresponding to a soft biological tissue and to a synthetic material. To this purpose, a device was designed based on the principle of the dynamic harness test. A moving load is considered and the force upon the indenter is controlled for loading-unloading phases. The load and specimen deformation are simultaneously recorded. A significant contribution of this paper is the interpolation of experimental data by power law functions, a difficult task because of the instability of the system of equations to be optimized. Finding the interpolation function was simplified, from solving a system of transcendental equations to solving a unique equation. The characteristic parameters of the experimentally curves must be compared to the ones corresponding to actual tissue. The tests were performed for two cases: first, using a spherical punch, and second, for a flat-ended cylindrical punch.
Smith, Shannon M; Dworkin, Robert H; Turk, Dennis C; Baron, Ralf; Polydefkis, Michael; Tracey, Irene; Borsook, David; Edwards, Robert R; Harris, Richard E; Wager, Tor D; Arendt-Nielsen, Lars; Burke, Laurie B; Carr, Daniel B; Chappell, Amy; Farrar, John T; Freeman, Roy; Gilron, Ian; Goli, Veeraindar; Haeussler, Juergen; Jensen, Troels; Katz, Nathaniel P; Kent, Jeffrey; Kopecky, Ernest A; Lee, David A; Maixner, William; Markman, John D; McArthur, Justin C; McDermott, Michael P; Parvathenani, Lav; Raja, Srinivasa N; Rappaport, Bob A; Rice, Andrew S C; Rowbotham, Michael C; Tobias, Jeffrey K; Wasan, Ajay D; Witter, James
2017-07-01
Valid and reliable biomarkers can play an important role in clinical trials as indicators of biological or pathogenic processes or as a signal of treatment response. Currently, there are no biomarkers for pain qualified by the U.S. Food and Drug Administration or the European Medicines Agency for use in clinical trials. This article summarizes an Initiative on Methods, Measurement, and Pain Assessment in Clinical Trials meeting in which 3 potential biomarkers were discussed for use in the development of analgesic treatments: 1) sensory testing, 2) skin punch biopsy, and 3) brain imaging. The empirical evidence supporting the use of these tests is described within the context of the 4 categories of biomarkers: 1) diagnostic, 2) prognostic, 3) predictive, and 4) pharmacodynamic. Although sensory testing, skin punch biopsy, and brain imaging are promising tools for pain in clinical trials, additional evidence is needed to further support and standardize these tests for use as biomarkers in pain clinical trials. The applicability of sensory testing, skin biopsy, and brain imaging as diagnostic, prognostic, predictive, and pharmacodynamic biomarkers for use in analgesic treatment trials is considered. Evidence in support of their use and outlining problems is presented, as well as a call for further standardization and demonstrations of validity and reliability. Copyright © 2017 American Pain Society. All rights reserved.
Fabrikant, I.; Karapetian, E.; Kalinin, S. V.
2017-12-09
Here, we consider the problem of an arbitrary shaped rigid punch pressed against the boundary of a transversely isotropic half-space and interacting with an arbitrary flat crack or inclusion, located in the plane parallel to the boundary. The set of governing integral equations is derived for the most general conditions, namely the presence of both normal and tangential stresses under the punch, as well as general loading of the crack faces. In order to verify correctness of the derivations, two different methods were used to obtain governing integral equations: generalized method of images and utilization of the reciprocal theorem. Bothmore » methods gave the same results. Axisymmetric coaxial case of interaction between a rigid inclusion and a flat circular punch both centered along the z-axis is considered as an illustrative example. Most of the final results are presented in terms of elementary functions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fabrikant, I.; Karapetian, E.; Kalinin, S. V.
Here, we consider the problem of an arbitrary shaped rigid punch pressed against the boundary of a transversely isotropic half-space and interacting with an arbitrary flat crack or inclusion, located in the plane parallel to the boundary. The set of governing integral equations is derived for the most general conditions, namely the presence of both normal and tangential stresses under the punch, as well as general loading of the crack faces. In order to verify correctness of the derivations, two different methods were used to obtain governing integral equations: generalized method of images and utilization of the reciprocal theorem. Bothmore » methods gave the same results. Axisymmetric coaxial case of interaction between a rigid inclusion and a flat circular punch both centered along the z-axis is considered as an illustrative example. Most of the final results are presented in terms of elementary functions.« less
de Almeida Jr, Hiram Larangeira; Siqueira, Rodrigo Nunes; Meireles, Renan da Silva; Rampon, Greice; de Castro, Luis Antonio Suita; Silva, Ricardo Marques e
2016-01-01
Pitted keratolysis is a skin disorder that affects the stratum corneum of the plantar surface and is caused by Gram-positive bacteria. A 30-year-old male presented with small punched-out lesions on the plantar surface. A superficial shaving was carried out for scanning electron microscopy. Hypokeratosis was noted on the plantar skin and in the acrosyringium, where the normal elimination of corneocytes was not seen. At higher magnification (x 3,500) bacteria were easily found on the surface and the described transversal bacterial septation was observed. PMID:26982791
Undiagnosed Small Fiber Polyneuropathy: Is It a Component of Gulf War Illness?
2011-07-01
After informed consent, a site (10 cm above the ankle ) is anesthetized and one or two 2- or 3mm diameter skin punches are removed using sterile...results anchor the lower end of the normal biopsy curve from which the multivariate analysis is derived. Thus, their biopsies will remain part of the...the findings in the young adult subjects, and also anchor the lower end of the neurite density curve, thus providing a more accurate normative fit
Ficken, James H.; Scott, Carl T.
1988-01-01
This manual describes the U.S. Geological Survey Minimonitor Water Quality Data Measuring and Recording System. Instructions for calibrating, servicing, maintaining, and operating the system are provided. The Survey Minimonitor is a battery-powered , multiparameter water quality monitoring instrument designed for field use. A watertight can containing signal conditioners is connected with cable and waterproof connectors to various water quality sensors. Data are recorded on a punched paper-tape recorder. An external battery is required. The operation and maintenance of various sensors and signal conditioners are discussed, for temperature, specific conductance, dissolved oxygen, and pH. Calibration instructions are provided for each parameter, along with maintenance instructions. Sections of the report explain how to connect the Minimonitor to measure direct-current voltages, such as signal outputs from other instruments. Instructions for connecting a satellite data-collection platform or a solid-state data recorder to the Minimonitor are given also. Basic information is given for servicing the Minimonitor and trouble-shooting some of its electronic components. The use of test boxes to test sensors, isolate component problems, and verify calibration values is discussed. (USGS)
Configurational phases in elastic foams under lengthscale-free punching
NASA Astrophysics Data System (ADS)
Sabuwala, Tapan; Dai, Xiangyu; Gioia, Gustavo
2016-08-01
We carry out experiments with brick-like specimens of elastic open-cell (EOC) foams of three relative densities. Individual specimens may be "tall" (height = width = depth) or "short" (2 height = width = depth). We place each specimen on a supporting plate and use a lengthscale-free (wedge-shaped or conical) punch to apply forces downward along the specimen's height. Regardless of the type of specimen, the force-penetration curves remain linear, for the wedge-shaped punch, or quadratic, for the conical punch, up to a sizable penetration commensurate with the smallest lengthscale of the specimen. After that there is an abrupt, all-but-discontinuous change in stiffness: if the specimen is tall, the stiffness drops; if the specimen is short, the stiffness shoots up. To analyze these curious experimental results, we posit that EOC foams can be found in either of two configurational phases, here termed the low-strain phase and the high-strain phase, which share a two-dimensional interface (a surface of strain discontinuity). The analysis may be outlined as follows. In the first part of an experiment, there obtains a "similarity regime" in which the penetration of the punch and the radius of the interface are the only prevailing lengthscales (because the punch is lengthscale free). In this case, it is possible to show that the force-penetration curve must be linear, or quadratic, depending on whether the punch be wedge-shaped or conical, respectively. This prediction of the analysis is consistent with the experiments. In time, the similarity regime breaks down when the interface reaches one of the specimen's boundaries distal to the tip of the punch. If the specimen is tall, the soft, stress-free lateral boundary is reached first, and the stiffness must drop; if the specimen is short, the hard boundary in contact with the supporting plate is reached first, and the stiffness must shoot up. These predictions too are consistent with the experiments. To provide direct empirical evidence of the interface, we use a digital-image correlation method. Lastly, we run computational simulations of all the experiments, using finite elements and the skeleton-and-bubble model of EOC foams. The computational results are in good accord with the experimental ones, and they allow us to carry out a detailed validation of the analysis. Our findings evince the cardinal role of configurational phases in the mechanics of EOC foams.
Pretzel, David; Linss, Stefanie; Ahrem, Hannes; Endres, Michaela; Kaps, Christian; Klemm, Dieter; Kinne, Raimund W
2013-01-01
Current therapies for articular cartilage defects fail to achieve qualitatively sufficient tissue regeneration, possibly because of a mismatch between the speed of cartilage rebuilding and the resorption of degradable implant polymers. The present study focused on the self-healing capacity of resident cartilage cells in conjunction with cell-free and biocompatible (but non-resorbable) bacterial nanocellulose (BNC). This was tested in a novel in vitro bovine cartilage punch model. Standardized bovine cartilage discs with a central defect filled with BNC were cultured for up to eight weeks with/without stimulation with transforming growth factor-β1 (TGF-β1. Cartilage formation and integrity were analyzed by histology, immunohistochemistry and electron microscopy. Content, release and neosynthesis of the matrix molecules proteoglycan/aggrecan, collagen II and collagen I were also quantified. Finally, gene expression of these molecules was profiled in resident chondrocytes and chondrocytes migrated onto the cartilage surface or the implant material. Non-stimulated and especially TGF-β1-stimulated cartilage discs displayed a preserved structural and functional integrity of the chondrocytes and surrounding matrix, remained vital in long-term culture (eight weeks) without signs of degeneration and showed substantial synthesis of cartilage-specific molecules at the protein and mRNA level. Whereas mobilization of chondrocytes from the matrix onto the surface of cartilage and implant was pivotal for successful seeding of cell-free BNC, chondrocytes did not immigrate into the central BNC area, possibly due to the relatively small diameter of its pores (2 to 5 μm). Chondrocytes on the BNC surface showed signs of successful redifferentiation over time, including increase of aggrecan/collagen type II mRNA, decrease of collagen type I mRNA and initial deposition of proteoglycan and collagen type II in long-term high-density pellet cultures. Although TGF-β1 stimulation showed protective effects on matrix integrity, effects on other parameters were limited. The present bovine cartilage punch model represents a robust, reproducible and highly suitable tool for the long-term culture of cartilage, maintaining matrix integrity and homoeostasis. As an alternative to animal studies, this model may closely reflect early stages of cartilage regeneration, allowing the evaluation of promising biomaterials with/without chondrogenic factors.
Code of Federal Regulations, 2011 CFR
2011-07-01
... beading, straightening, corrugating, flanging, or bending rolls; and hot or cold rolling mills. (ii) All... area between the dies; power presses; and plate punches. (iii) All bending machines, such as apron...
Tag gas capsule with magnetic piercing device
Nelson, Ira V.
1976-06-22
An apparatus for introducing a tag (i.e., identifying) gas into a tubular nuclear fuel element. A sealed capsule containing the tag gas is placed in the plenum in the fuel tube between the fuel and the end cap. A ferromagnetic punch having a penetrating point is slidably mounted in the plenum. By external electro-magnets, the punch may be caused to penetrate a thin rupturable end wall of the capsule and release the tag gas into the fuel element. Preferably the punch is slidably mounted within the capsule, which is in turn loaded as a sealed unit into the fuel element.
16. SOUTH TO VIEW OF CIRCA 1900 MICHIGAN MACHINERY MFG. ...
16. SOUTH TO VIEW OF CIRCA 1900 MICHIGAN MACHINERY MFG. CO. PUNCH PRESS WITH WOOD-BURNING HEATING STOVE LOCATED IN THE CENTER OF THE FACTORY BUILDING. BESIDE THE HEATING STOVE, POINTING TOWARD THE PUNCH PRESS, IS A JIG USED TO POSITION ANGLE STEEL COMPONENTS OF STEEL WINDMILL TOWER LEGS FOR PUNCHING BOLT HOLES. THE SUPPORT FOR THE BRICK FLUE OF THE HEATING STOVE IS CONSTRUCTED FROM SALVAGED GALVANIZED ANGLE STEEL OF THE TYPE USED IN FABRICATING WINDMILL TOWERS MANUFACTURED IN THE FACTORY. - Kregel Windmill Company Factory, 1416 Central Avenue, Nebraska City, Otoe County, NE
Wang, Jing; Cherkassky, Vladimir L; Yang, Ying; Chang, Kai-Min Kevin; Vargas, Robert; Diana, Nicholas; Just, Marcel Adam
2016-01-01
The generativity and complexity of human thought stem in large part from the ability to represent relations among concepts and form propositions. The current study reveals how a given object such as rabbit is neurally encoded differently and identifiably depending on whether it is an agent ("the rabbit punches the monkey") or a patient ("the monkey punches the rabbit"). Machine-learning classifiers were trained on functional magnetic resonance imaging (fMRI) data evoked by a set of short videos that conveyed agent-verb-patient propositions. When tested on a held-out video, the classifiers were able to reliably identify the thematic role of an object from its associated fMRI activation pattern. Moreover, when trained on one subset of the study participants, classifiers reliably identified the thematic roles in the data of a left-out participant (mean accuracy = .66), indicating that the neural representations of thematic roles were common across individuals.
Regional assessment of energy-producing metabolic activity in the endothelium of donor corneas.
Greiner, Mark A; Burckart, Kimberlee A; Wagoner, Michael D; Schmidt, Gregory A; Reed, Cynthia R; Liaboe, Chase A; Flamme-Wiese, Miles J; Zimmerman, M Bridget; Mullins, Robert F; Kardon, Randy H; Goins, Kenneth M; Aldrich, Benjamin T
2015-05-01
We characterized mitochondrial respiration and glycolysis activity of human corneal endothelium, and compared metabolic activity between central and peripheral regions. Endothelial keratoplasty-suitable corneas were obtained from donors aged 50 to 75 years. The endothelium-Descemet membrane complex (EDM) was isolated, and 3-mm punches were obtained from central and peripheral regions. Endothelium-Descemet membrane punches were assayed for mitochondrial respiration (oxygen consumption) and glycolysis (extracellular acidification) using an extracellular flux analyzer. Enzymatic (citrate synthase, glucose hexokinase) and mitochondrial density (MitoTracker) assays also were performed. Ten corneas were analyzed per assay. Metabolic activity for mitochondrial respiration and glycolysis showed expected changes to assay compounds (P < 0.01, all pairwise comparisons). Basal mitochondrial respiration and glycolysis activity did not differ between regions (P > 0.99). Similarly, central versus peripheral activity after assay compound treatment showed no significant differences (P > 0.99, all time points). The intracorneal coefficient of variation for basal readings between two and four peripheral punches was 18.5% of the mean. Although peripheral samples displayed greater enzymatic activity than central samples (P < 0.05), similar to extracellular flux results, mitochondrial density did not differ between regions (P = 0.78). Extracellular flux analysis of oxygen and pH is a valid technique for characterizing metabolic activity of human corneal endothelium. This technique demonstrates high reproducibility, allows quantification of metabolic parameters using small quantities of live cells, and permits estimation of overall metabolic output. Neither oxygen consumption nor extracellular acidification differed between central and peripheral regions of transplant suitable corneas in this series. Our results show that endothelial cell health can be quantified biochemically in transplant suitable corneas.
1982-07-01
WE ii-" BOR # 66i596 FUNCTION: PUNCH CMTROLL MUTER MING: H RON: A POSITION-.. 8 PREEST POST TEST RES.LTS CONECTOR VOLTAG RESISTANCE VOLTAG RESISTNCE...O 86=±w RHNCTION. PRINTR CONTROLLER COMPUTER WING: A ROW: A POSITION. U2 PRETEST POST TEST RMlTS CONECTOR YOLTAGI RESISIWICE YOLTAGE RESISTI9ICE...WING: A ROW: A POSITION. 12 PRUEST POST TEST RMJLTS CONECTOR VOLT(iE FIS’IS VOLTAGE RISTFICE VOLTAGE S1INCE (VOLTS) (fILLIOM ) (VOLTS) (MILLIOMS
41 CFR 101-26.703 - Marginally punched continuous forms.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 41 Public Contracts and Property Management 2 2010-07-01 2010-07-01 true Marginally punched continuous forms. 101-26.703 Section 101-26.703 Public Contracts and Property Management Federal Property Management Regulations System FEDERAL PROPERTY MANAGEMENT REGULATIONS SUPPLY AND PROCUREMENT 26-PROCUREMENT...
VO₂ requirements of boxing exercises.
Arseneau, Eric; Mekary, Saïd; Léger, Luc A
2011-02-01
The purpose of this study was to quantify the physiological requirements of various boxing exercises such as sparring, pad work, and punching bag. Because it was not possible to measure the oxygen uptake (VO₂) of "true" sparring with a collecting gas valve in the face, we developed and validated a method to measure VO₂ of "true" sparring based on "postexercise" measurements. Nine experienced male amateur boxers (Mean ± SD: age = 22.0 ± 3.5 years, height = 176.0 ± 8.0 cm, weight = 71.4 ± 10.9 kg, number of fights = 13.0 ± 9.5) of regional and provincial level volunteered to participate in 3 testing sessions: (a) maximal treadmill test in the LAB, (b) standardized boxing training in the GYM, and (c) standardized boxing exercises in the LAB. Measures of VO₂, heart rate (HR), blood lactate concentration [LA], rated perceived exertion level, and punching frequencies were collected. VO₂ values of 43.4 ± 5.9, 41.1 ± 5.1, 24.7 ± 6.1, 30.4 ± 5.8, and 38.3 ± 6.5 ml·kg⁻¹·min⁻¹ were obtained, which represent 69.7 ± 8.0, 66.1 ± 8.0, 39.8 ± 10.4, 48.8 ± 8.5, and 61.7 ± 10.3%VO₂peak for sparring, pad work, and punching bag at 60, 120, and 180 b·min⁻¹, respectively. Except for lower VO₂ values for punching the bag at 60 and 120 b·min⁻¹ (p < 0.05), there was no VO₂ difference between exercises. Similar pattern was obtained for %HRmax with respective values of 85.5 ± 5.9, 83.6 ± 6.3, 67.5 ± 3.5, 74.8 ± 5.9, and 83.0 ± 6.0. Finally, sparring %HRmax and [LA] were slightly higher in the GYM (91.7 ± 4.3 and 9.4 ± 2.2 mmol·L⁻¹) vs. LAB (85.5 ± 5.9 and 6.1 ± 2.3 mmol·L⁻¹). Thus, in this study simulated LAB sparring and pad work required similar VO₂ (43-41 ml·kg⁻¹·min⁻¹, respectively), which corresponds to ~70%VO₂peak. These results underline the importance of a minimum of aerobic fitness for boxers and draw some guidelines for the intensity of training.
Atha, J; Yeadon, M R; Sandover, J; Parsons, K C
1985-01-01
The mechanical properties of a boxing punch have been determined using several techniques. The results are consistent with the medical consequences of boxing discussed in the report of the Board of Science and Education Working Party on boxing. Data were gathered from a world ranked British professional heavyweight, Frank Bruno, as he punched an instrumented, padded target mass suspended as a ballistic pendulum. Within 0.1 s of the start the punch had travelled 0.49 m and attained a velocity on impact of 8.9 m/s. The peak force on impact of 4096N (0.4 ton), attained within 14 ms of contact, represents a blow to the human head of up to 6320N (0.63 ton). The transmitted impulse generated an acceleration of 520 m/s2 (53 g) in the target head. For comparison an equivalent blow would be delivered by a padded wooden mallet with a mass of 6 kg (13 lbs) if swung at 20 mph. Images FIG 1 FIG 2 PMID:3936571
Prosodic Markers of Saliency in Humorous Narratives
ERIC Educational Resources Information Center
Pickering, Lucy; Corduas, Marcella; Eisterhold, Jodi; Seifried, Brenna; Eggleston, Alyson; Attardo, Salvatore
2009-01-01
Much of what we think we know about the performance of humor relies on our intuitions about prosody (e.g., "it's all about timing"); however, this has never been empirically tested. Thus, the central question addressed in this article is whether speakers mark punch lines in jokes prosodically and, if so, how. To answer this question,…
Analysis of direct punch velocity in professional defence
NASA Astrophysics Data System (ADS)
Lapkova, Dora; Adamek, Milan
2016-06-01
This paper is focused on analysis of a direct punch. Nowadays, professional defence is basic part of effective protection of people and property. There are many striking techniques and the goal of this research was to analyze the direct punch. The analysis is aimed to measure the velocity with help of high speed camera Olympus i-Speed 2 and then find the dependences of this velocity on input parameters. For data analysis two pieces of software were used - i-Speed Control Software and MINITAB. 111 participants took part in this experiment. The results are presented in this paper - especially dependence of mean velocity on time and difference in velocity between genders.
Armour, Katherine; Mann, Stephen; Lee, Stephen
2005-05-01
The management of dysplastic naevi is a controversial subject. This study sought to assess the usefulness of the shave biopsy technique in the initial management of dysplastic naevi, and to demonstrate the advantages over the punch biopsy technique. We report a retrospective observational study of histopathology specimens examined in one histopathology practice over a 14-month period. Patients who had a clinical diagnosis of 'dysplastic naevus', which had initially been biopsied using either a shave or punch biopsy, and then followed up with a full-thickness elliptical excision, were included in the study. Histopathological concordance between the shave and punch biopsy specimens and their respective follow-up elliptical excisions was compared. We found that 21 of 22 (95.5%) shave biopsies were concordant with their respective excision specimens, and that 29 of 41 (70.7%) punch biopsies were concordant with their respective elliptical excision specimens. Of the shave biopsy specimens reviewed, 66% showed that the dysplastic naevi were completely excised with the initial biopsy, compared with 21.2% of the punch biopsy specimens. These findings confirm that shave biopsies provide accurate diagnostic information in the assessment of dysplastic naevi. Shave biopsies enable the entire lesion to be submitted for histopathological assessment, improving the chances of an accurate diagnosis.
Hole expansion test of third generation steels
NASA Astrophysics Data System (ADS)
Agirre, Julen; Mendiguren, Joseba; Galdos, Lander; de Argandoña, Eneko Sáenz
2017-10-01
The trend towards the implementation of new materials in the chassis of the automobiles is considerably making more complex the manufacturing of the components that built it up. In this scenario materials with higher strengths and lower formabilities are daily faced by tool makers and component producers what reduces the process windows and makes the forming processes to be in the limits of the materials. One of the concerns that tool makers must face during the definition of the tools is the expansion ratios that the holes in the sheet may reach before producing a breakage due to the stretching of the material (also known as edge cracks). For the characterization of such limits, a standard test, the hole expansion test, can be applied so that the limits of the material are known. At the present study, hole expansion tests of a third generation steel, Fortiform1050 with a thickness of 1.2 millimeters have been carried out and compared them to a mild steel, DX54D with a thickness of 0.6 millimeters. A comparison for each material in terms of technology used to punch the hole, mechanical punching vs laser cutting has also been conducted. In addition, the measurement technique (online measurement vs offline measurement) followed in the Hole Expansion Ratio (HER) identification has also been analyzed. Finally, differences between both materials and techniques are presented.
Promoting Response Variability and Stimulus Generalization in Martial Arts Training
ERIC Educational Resources Information Center
Harding, Jay W.; Wacker, David P.; Berg, Wendy K.; Rick, Gary; Lee, John F.
2004-01-01
The effects of reinforcement and extinction on response variability and stimulus generalization in the punching and kicking techniques of 2 martial arts students were evaluated across drill and sparring conditions. During both conditions, the students were asked to demonstrate different techniques in response to an instructor's punching attack.…
Miller, M K; Strauchen, J A; Nichols, K T; Phelps, R G
2001-08-01
Patients who have chronic lymphocytic leukemia (CLL) are known to have a high frequency of second malignant neoplasms. However, acute myelogenous leukemia (AML) occurring concurrent with or after a diagnosis of CLL is extremely rare. In this article we report a case of AML developing in a 55-year-old male with a 6-year history of untreated CLL. The diagnosis was facilitated by touch preparation of a skin punch biopsy specimen. The patient presented with a two-week history of fever, weakness, anasarca, and a skin rash. Physical examination revealed pink to skin-colored firm papules, which coalesced into indurated plaques on his trunk, upper extremities, and face. The lesions, in combination with generalized edema, produced a leonine facies. Touch prep of the biopsy showed medium to large blasts, large monocytoid cells, and numerous small mature lymphocytes, providing the preliminary diagnosis of a second, previously undiagnosed myelomonocytic malignancy in this patient. The initial diagnosis was subsequently confirmed by histologic, cytochemical, immunohistochemical and flow cytometry studies. This is the first reported case of CLL with concurrent AML in which rapid touch prep of a skin punch biopsy facilitated diagnosis.
Method for hot pressing irregularly shaped refractory articles
Steinkamp, William E.; Ballard, Ambrose H.
1982-01-01
The present invention is directed to a method for hot pressing irregularly haped refractory articles with these articles of varying thickness being provided with high uniform density and dimensional accuracy. Two partially pressed compacts of the refractory material are placed in a die cavity between displaceable die punches having compact-contacting surfaces of the desired article configuration. A floating, rotatable block is disposed between the compacts. The displacement of the die punches towards one another causes the block to rotate about an axis normal to the direction of movement of the die punches to uniformly distribute the pressure loading upon the compacts for maintaining substantially equal volume displacement of the powder material during the hot pressing operation.
Krishnaiah, Yellela S R; Katragadda, Usha; Khan, Mansoor A
2014-05-01
Cold flow is a phenomenon occurring in drug-in-adhesive type of transdermal drug delivery systems (DIA-TDDS) because of the migration of DIA coat beyond the edge. Excessive cold flow can affect their therapeutic effectiveness, make removal of DIA-TDDS difficult from the pouch, and potentially decrease available dose if any drug remains adhered to pouch. There are no compendial or noncompendial methods available for quantification of this critical quality attribute. The objective was to develop a method for quantification of cold flow using stereomicroscopic imaging technique. Cold flow was induced by applying 1 kg force on punched-out samples of marketed estradiol DIA-TDDS (model product) stored at 25°C, 32°C, and 40°C/60% relative humidity (RH) for 1, 2, or 3 days. At the end of testing period, dimensional change in the area of DIA-TDDS samples was measured using image analysis software, and expressed as percent of cold flow. The percent of cold flow significantly decreased (p < 0.001) with increase in size of punched-out DIA-TDDS samples and increased (p < 0.001) with increase in cold flow induction temperature and time. This first ever report suggests that dimensional change in the area of punched-out samples stored at 32°C/60%RH for 2 days applied with 1 kg force could be used for quantification of cold flow in DIA-TDDS. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.
Performance improvement in a tubular heat exchanger by punched delta-winglet vortex generators
NASA Astrophysics Data System (ADS)
Khanoknaiyakarn, C.; Promvonge, P.; Thianpong, C.; Skullong, S.
2018-01-01
A novel tubular heat exchanger incorporated with punched delta-winglet vortex generators (called perforated delta-winglet vortex generator, P-DWVG) is proposed for improving its thermal performance and energy saving. The P-DWVG elements are punched out from a straight tape having its width nearly equal to the tube diameter before insertion. The main aim at employing the P-DWVG insert is to produce counter-rotating vortices along the tube to promote turbulence intensity inside as well as to transport the cold fluid at the central core to the near-wall regions. The experiment was performed to study thermal behaviors in a uniform heat-fluxed tube inserted with P-DWVGs. The P-DWVGs with the attack angle of 45° were mounted periodically with three different blockage ratios (BR = 0.1, 0.2 and 0.3) and two pitch ratios (PR = 2 and 3). Air as the test fluid was varied to obtain turbulent airflow for Reynolds number (Re) in a range of 4,150-25,500. The experimental results show that the P-DWVG provides a considerable increase in the rate of heat transfer around 3.1-4.01 times whereas friction factor increases around 11.44- 34.23 times higher than the plain tube. To assess the real benefits of P-DWVGs, thermal performance factor (TEF) is examined and in the range of 1.39-1.48 where its maximum is at BR = 0.1 and PR = 2.
Evaluation of consolidation method on mechanical and structural properties of ODS RAF steel
NASA Astrophysics Data System (ADS)
Frelek-Kozak, M.; Kurpaska, L.; Wyszkowska, E.; Jagielski, J.; Jozwik, I.; Chmielewski, M.
2018-07-01
In the present work, the effects of the fabrication method on mechanical and structural properties of 12%Cr, 2%W, 0.25%Ti, 0.25%Y2O3 steels were investigated. Materials obtained by Spark Plasma Sintering (SPS), Hot Isostatic Pressing (HIP) and Hot Extrusion (HE) methods were studied. The microstructure was characterized by using Scanning Electron Microscopy (SEM) and Electron Backscatter Diffraction analysis (EBSD). Mechanical properties of the studied samples were evaluated by using Vickers micro hardness HV0.1, Small Punch Test (SPT) and nanoindentation (NI) methods. The analysis revealed that samples manufactured via HIP and SPS processes exhibit very similar properties, whereas SPS method produces material with slightly lower hardness. In addition, significantly lower mechanical properties of the specimens after HE process were observed. The study described in this article addresses also the problems of mechanical parameters measured in micro- and nano-scale experiments and aims to identify possible pitfalls related to the use of various manufacturing technologies.
Enhancements to the Image Analysis Tool for Core Punch Experiments and Simulations (vs. 2014)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hogden, John Edward; Unal, Cetin
A previous paper (Hogden & Unal, 2012, Image Analysis Tool for Core Punch Experiments and Simulations) described an image processing computer program developed at Los Alamos National Laboratory. This program has proven useful so developement has been continued. In this paper we describe enhacements to the program as of 2014.
PUNCHED CARD SYSTEM NEEDN'T BE COMPLEX TO GIVE COMPLETE CONTROL.
ERIC Educational Resources Information Center
BEMIS, HAZEL T.
AT WORCESTER JUNIOR COLLEGE, MASSACHUSETTS, USE OF A MANUALLY OPERATED PUNCHED CARD SYSTEM HAS RESULTED IN (1) SIMPLIFIED REGISTRATION PROCEDURES, (2) QUICK ANALYSIS OF CONFLICTS AND PROBLEMS IN CLASS SCHEDULING, (3) READY ACCESS TO STATISTICAL INFORMATION, (4) DIRECTORY INFORMATION IN A WIDE RANGE OF CLASSIFICATIONS, (5) EASY VERIFICATION OF…
Tyagi, Natasha; Suneja, Amita; Mishra, Kiran; Jain, Sandhya; Vaid, Neelam Bala; Guleria, Kiran
2017-01-01
To assess the feasibility and efficacy of Keyes punch biopsy instrument (KP) in diagnosing cervical lesions and compare it with cervical punch biopsy forceps (CP). 75 women having satisfactory colposcopy with abnormal transformation zone were included and paired colposcopic directed biopsies were taken using KP followed by CP from the same target area. It was feasible in all cases to take cervical biopsy with KP after increasing its effective length. The volume of gross specimen obtained by KP was less than CP (0.076 ± 0.097 vs. 0.101 ± 0.156 cm3, p = 0.061), however on microscopic examination, mean length and mean depth of tissue in KP was greater than CP by 0.06 mm (p = 0.810) and 0.14 mm (p = 0.634) respectively. Exact agreement was found with the final surgical specimen in 42% of cases in both the biopsy forceps. KP is almost at par with CP for diagnosing preinvasive cervical lesions and is a useful adjunct to the existing armamentarium of biopsy forceps. © 2016 S. Karger AG, Basel.
Göktay, Fatih; Altan, Zeynep Müzeyyen; Talas, Anıl; Akpınar, Esma; Özdemir, Ekin Özge; Aytekin, Sema
2016-01-01
Patient anxiety about nail surgery relates mainly to pain associated with needle puncture, anesthetic flow during the procedure, and postoperative care, as well as possible past traumatic experience. The aims of this study were to compare anxiety levels among patients undergoing nail surgery and skin punch biopsy and to assess the effects of demographic characteristics on anxiety. Forty-eight consecutive patients who were referred to a dermatological surgery unit for nail surgery intervention (group 1) and 50 age- and sex-matched patients referred to the same unit for skin punch biopsy (group 2) were enrolled in the study. Patients' anxiety levels were measured using Spielberger's State-Trait Anxiety Inventory. There was no significant difference in median anxiety level between group 1 (42.00; interquartile range, 6.50) and group 2 (41.00; interquartile range, 8.25) (P = .517). The demographic factors of patient sex, educational status, and prior surgery showed no significant effects on anxiety levels. Nail surgery does not seem to cause significantly greater anxiety than skin punch biopsy. © The Author(s) 2015.
Lawson, A J; Bernstone, L; Hall, S K
2016-03-01
In dried blood spot analysis, punch location and variations in applied sample volume and haematocrit can produce different measured concentrations of analytes. We investigated the magnitude of these effects in newborn screening in the UK. Heparinized blood spiked with thyroid stimulating hormone (TSH), phenylalanine, tyrosine, leucine, methionine, octanoyl carnitine (C8), and immunoreactive trypsinogen (IRT) was spotted onto filter paper: (i) at a constant haematocrit of 50% at various volumes, and (ii) at a range of haematocrits using a constant volume. Subpunches (3.2 mm) of the dried blood spots were then analysed. Compared with a central punch from a 50 µL blood spot with 50% haematocrit, 10 µL spots can have significantly lower measured concentrations of all analytes, with decreases of 15% or more observed for leucine, methionine, phenylalanine, and tyrosine. Punching at the edge of a spot can increase measured concentrations up to 35%. Higher haematocrit decreased measured TSH and C8 yet increased amino acids and IRT by 15% compared with 50% haematocrit. Lower haematocrits had the opposite effect, but only with higher concentrations of some analytes. Differences in blood spot size, haematocrit and punch location substantially affect measured concentrations for analytes used in the UK newborn screening programme, and this could affect false positive and negative rates. To minimize analytical bias, these variables should be controlled or adjusted for where possible. © The Author(s) 2015.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saleh, Tarik A.; Quintana, Matthew Estevan; Romero, Tobias J.
As a part of the project “High Fidelity Ion Beam Simulation of High Dose Neutron Irradiation” an Integrated Research Program (IRP) project from the U.S. Department of Energy, Nuclear Energy University Programs (NEUP), TEM geometry samples of ferritic cladding alloys, Ni based super alloys and model alloys were irradiated in the BOR-60 reactor to ~16 dpa at ~370°C and ~400°C. Samples were sent to Los Alamos National Laboratory and subjected to shear punch testing. This report presents the results from this testing.
C-shaped specimen plane strain fracture toughness tests. [metallic materials
NASA Technical Reports Server (NTRS)
Buzzard, R. T.; Fisher, D. M.
1977-01-01
Test equipment, procedures, and data obtained in the evaluation of C-shaped specimens are presented. Observations reported on include: specimen preparation and dimensional measurement; modifications to the standard ASTM E 399 displacement gage, which permit punch mark gage point engagement; and a measurement device for determining the interior and exterior radii of ring segments. Load displacement ratios were determined experimentally which agreed with analytically determined coefficients for three different gage lengths on the inner surfaces of radially-cracked ring segments.
Davis, Philip; Waldock, Robert; Connorton, Andrew; Driver, Sonny; Anderson, Sean
2018-06-01
The effect of the rules change in 2013 on amateur boxing strategy, technique and safety in comparison with pre-2013 is unknown. Pre-2013 and post-2013 3×3 min elite level amateur boxing was compared from video footage of 29 Olympic (pre-2013) and 50 World Championship bouts (post-2013) totalling 99 male boxers (mean±SD) age: 24.3±3.2 years, height: 177.3±11.3 cm and body mass: 70.7±16.4 kg. Many techniques that were dominant pre-2013 were used less post-2013, including: total punches thrown, rear hand punches, hook rear hand, punches landed, uppercut punches, total punches to the body (all <0.05), while movement around the ring and defensive movements were higher post-2013 (both p<0.004). Post-2013 boxers have increased their foot movement by 20% to move in and then away from their opponent, combined with long-range punches and deliberate defensive movements. The percentage of rounds where standing counts were issued changed from 9% to 3% pre-2013 to post-2013. However, pre-2013, 1.7% of bouts did not last the full duration due to referee stoppage, while post-2013, this increased to 4.2% as a result of two knockouts and eight technical knockouts. Boxers should be aware of the large changes in technical demands of boxing. An increased risk of concussive or traumatic brain injury post-2013 is equivocal. However, an increase in skin splits and technical knockouts is apparent. It is likely that boxers believe head guard removal has made them more prone to knockouts. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Choi, Seunghee; Coon, Joshua J.; Goggans, Matthew Scott; Kreisman, Thomas F.; Silver, Daniel M.; Nesson, Michael H.
2016-01-01
Many of the materials that are challenging for large animals to cut or puncture are also cut and punctured by much smaller organisms that are limited to much smaller forces. Small organisms can overcome their force limitations by using sharper tools, but one drawback may be an increased susceptibility to fracture. We use simple contact mechanics models to estimate how much smaller the diameter of the tips or edges of tools such as teeth, claws and cutting blades must be in smaller organisms in order for them to puncture or cut the same materials as larger organisms. In order to produce the same maximum stress when maximum force scales as the square of body length, the diameter of the tool region that is in contact with the target material must scale isometrically for punch-like tools (e.g. scorpion stings) on thick targets, and for crushing tools (e.g. molars). For punch-like tools on thin targets, and for cutting blades on thick targets, the tip or edge diameters must be even smaller than expected from isometry in smaller animals. The diameters of a small sample of unworn punch-like tools from a large range of animal sizes are consistent with the model, scaling isometrically or more steeply (positively allometric). In addition, we find that the force required to puncture a thin target using real biological tools scales linearly with tip diameter, as predicted by the model. We argue that, for smaller tools, the minimum energy to fracture the tool will be a greater fraction of the minimum energy required to puncture the target, making fracture more likely. Finally, energy stored in tool bending, relative to the energy to fracture the tool, increases rapidly with the aspect ratio (length/width), and we expect that smaller organisms often have to employ higher aspect ratio tools in order to puncture or cut to the required depth with available force. The extra stored energy in higher aspect ratio tools is likely to increase the probability of fracture. We discuss some of the implications of the suggested scaling rules and possible adaptations to compensate for fracture sensitivity in smaller organisms. PMID:27274804
Disassembly Properties of Cementitious Finish Joints Using an Induction Heating Method
Ahn, Jaecheol; Noguchi, Takafumi; Kitagaki, Ryoma
2015-01-01
Efficient maintenance and upgrading of a building during its lifecycle are difficult because a cementitious finish uses materials and parts with low disassembly properties. Additionally, the reuse and recycling processes during building demolition also present numerous problems from the perspective of environmental technology. In this study, an induction heating (IH) method was used to disassemble cementitious finish joints, which are widely used to join building members and materials. The IH rapidly and selectively heated and weakened these joints. The temperature elevation characteristics of the cementitious joint materials were measured as a function of several resistor types, including wire meshes and punching metals, which are usually used for cementitious finishing. The disassembly properties were evaluated through various tests using conductive resistors in cementitious joints such as mortar. When steel fiber, punching metal, and wire mesh were used as conductive resistors, the cementitious modifiers could be weakened within 30 s. Cementitious joints with conductive resistors also showed complete disassembly with little residual bond strength.
Experimental Analysis of Japanese Martial Art Nihon-Kempo
ERIC Educational Resources Information Center
Kuragano, Tetsuzo; Yokokura, Saburo
2012-01-01
With a male, adult subject, this study measured the punch force and kick force of the Japanese martial art Nihon-Kempo, the movements of the dominant (right) arm, leg, and the movements of the legs using timed synchronization. Using an electromyogram (EMG), the relationship between the variation of punch force and the variation of the electrical…
Computing Gross Pay from Punched Time Cards. Student Manual and Instructor's Manual.
ERIC Educational Resources Information Center
McElveen, Peggy C.
Supporting performance objective 30 of the V-TECS (Vocational-Technical Education Consortium of States) Secretarial Catalog, both a set of student materials and an instructor's manual on computing gross pay from punched time cards are included in this packet, which is part of a series. The student materials include a group of time cards,…
Development and Validation of a Shear Punch Test Fixture
2013-08-01
composites (MMC) manufactured by friction stir processing (FSP) that are being developed as part of a Technology Investment Fund (TIF) project, as the...leading a team of government departments and academics to develop a friction stir processing (FSP) based procedure to create metal matrix composite... friction stir process to fabricate surface metal matrix composites in aluminum alloys for potential application in light armoured vehicles. The
Using Diffusion Bonding in Making Piezoelectric Actuators
NASA Technical Reports Server (NTRS)
Sager, Frank E.
2003-01-01
A technique for the fabrication of piezoelectric actuators that generate acceptably large forces and deflections at relatively low applied voltages involves the stacking and diffusion bonding of multiple thin piezoelectric layers coated with film electrodes. The present technique stands in contrast to an older technique in which the layers are bonded chemically, by use of urethane or epoxy agents. The older chemical-bonding technique entails several disadvantages, including the following: It is difficult to apply the bonding agents to the piezoelectric layers. It is difficult to position the layers accurately and without making mistakes. There is a problem of disposal of hazardous urethane and epoxy wastes. The urethane and epoxy agents are nonpiezoelectric materials. As such, they contribute to the thickness of a piezoelectric laminate without contributing to its performance; conversely, for a given total thickness, the performance of the laminate is below that of a unitary piezoelectric plate of the same thickness. The figure depicts some aspects of the fabrication of a laminated piezoelectric actuator by the present diffusion- bonding technique. First, stock sheets of the piezoelectric material are inspected and tested. Next, the hole pattern shown in the figure is punched into the sheets. Alternatively, if the piezoelectric material is not a polymer, then the holes are punched in thermoplastic films. Then both faces of each punched piezoelectric sheet or thermoplastic film are coated with a silver-ink electrode material by use of a silkscreen printer. The electrode and hole patterns are designed for minimal complexity and minimal waste of material. After a final electrical test, all the coated piezoelectric layers (or piezoelectric layers and coated thermoplastic films) are stacked in an alignment jig, which, in turn, is placed in a curved press for the diffusion-bonding process. In this process, the stack is pressed and heated at a specified curing temperature and pressure for a specified curing time. The pressure, temperature, and time depend on the piezoelectric material selected. At the end of the diffusion-bonding process, the resulting laminated piezoelectric actuator is tested to verify the adequacy of the mechanical output as a function of an applied DC voltage.
Treatment of Die-Punch Fractures with 3D Printing Technology.
Chen, Chunhui; Cai, Leyi; Zhang, Chuanxu; Wang, Jianshun; Guo, Xiaoshan; Zhou, Yifei
2017-07-19
We evaluated the feasibility, accuracy and effectiveness of applying three-dimensional (3D) printing technology for preoperative planning for die-punch fractures. A total of 107 patients who underwent die-punch fracture surgery were enrolled in the study. They were randomly divided into two groups: 52 cases in the 3D model group and 55 cases in the routine group. A 3D digital model of each die-punch fracture was reconstructed in the 3D group. The 3D digital model was imported to a 3D printer to build the full solid model. The operation time, blood loss volume, and the number of intraoperative fluoroscopy were recorded. Follow-up was performed to evaluate the patients' surgical outcomes. Treatment of die-punch fractures using the 3D printing approach reduced the number of intraoperative fluoroscopy, blood loss volume, and operation time, but did not improve wrist function compared to those in the routine group. The patients wanted the doctor to use the 3D model to introduce the condition and operative plan because it was easier for them to understand. The orthopedic surgeons thought that the 3D model was useful for communicating with their patients, but their satisfaction with the preoperative plan was much lower than the benefit of using the 3D model to communicate with their patients. 3D printing technology produced more accurate morphometric information for orthopedists to provide personalized surgical planning and communicate better with their patients. However, it is difficult to use widely in the department of orthopedics.
ERIC Educational Resources Information Center
Sedaghat, Ahmad; AlJundub, Mohammad; Eilaghi, Armin; Bani-Hani, Ehab; Sabri, Farhad; Mbarki, Raouf; Assad, M. El Haj
2017-01-01
The PBL unit of fluid and electrical drive systems is taught in final semester of undergraduates in mechanical engineering department of the Australian College of Kuwait (ACK). The recent project on an automated punching machine is discovered more appealing to both students and instructors in triggering new ideas and satisfaction end results. In…
Mechanization in a New Medical School Library II. Serials and Circulation
Payne, Ladye Margarete; Small, Louise; Divett, Robert T.
1966-01-01
The serials and circulation phases of the data-processing system in use at the University of New Mexico Library of the Medical Sciences are described. The development of the programs is also reported. The serials program uses simple punched card equipment. The circulation program uses the IBM 357 Data Collection System and punched card data-processing equipment. Images PMID:5921473
Mobile Timekeeping Application Built on Reverse-Engineered JPL Infrastructure
NASA Technical Reports Server (NTRS)
Witoff, Robert J.
2013-01-01
Every year, non-exempt employees cumulatively waste over one man-year tracking their time and using the timekeeping Web page to save those times. This app eliminates this waste. The innovation is a native iPhone app. Libraries were built around a reverse- engineered JPL API. It represents a punch-in/punch-out paradigm for timekeeping. It is accessible natively via iPhones, and features ease of access. Any non-exempt employee can natively punch in and out, as well as save and view their JPL timecard. This app is built on custom libraries created by reverse-engineering the standard timekeeping application. Communication is through custom libraries that re-route traffic through BrowserRAS (remote access service). This has value at any center where employees track their time.
Finite Element Analysis of Plastic Deformation During Impression Creep
NASA Astrophysics Data System (ADS)
Naveena; Ganesh Kumar, J.; Mathew, M. D.
2015-04-01
Finite element (FE) analysis of plastic deformation associated with impression creep deformation of 316LN stainless steel was carried out. An axisymmetric FE model of 10 × 10 × 10 mm specimen with 1-mm-diameter rigid cylindrical flat punch was developed. FE simulation of impression creep deformation was performed by assuming elastic-plastic-power-law creep deformation behavior. Evolution of the stress with time under the punch during elastic, plastic, and creep processes was analyzed. The onset of plastic deformation was found to occur at a nominal stress about 1.12 times the yield stress of the material. The size of the developed plastic zone was predicted to be about three times the radius of the punch. The material flow behavior and the pile-up on specimen surface have been modeled.
Badal Tejedor, Maria; Nordgren, Niklas; Schuleit, Michael; Millqvist-Fureby, Anna; Rutland, Mark W
2017-11-21
Adhesion of the powders to the punches is a common issue during tableting. This phenomenon is known as sticking and affects the quality of the manufactured tablets. Defective tablets increase the cost of the manufacturing process. Thus, the ability to predict the tableting performance of the formulation blend before the process is scaled-up is important. The adhesive propensity of the powder to the tableting tools is mostly governed by the surface-surface adhesive interactions. Atomic force microscopy (AFM) colloidal probe is a surface characterization technique that allows the measurement of the adhesive interactions between two materials of interest. In this study, AFM steel colloidal probe measurements were performed on ibuprofen, MCC (microcrystalline cellulose), α-lactose monohydrate, and spray-dried lactose particles as an approach to modeling the punch-particle surface interactions during tableting. The excipients (lactose and MCC) showed constant, small, attractive, and adhesive forces toward the steel surface after a repeated number of contacts. In comparison, ibuprofen displayed a much larger attractive and adhesive interaction increasing over time both in magnitude and in jump-in/jump-out separation distance. The type of interaction acting on the excipient-steel interface can be related to a van der Waals force, which is relatively weak and short-ranged. By contrast, the ibuprofen-steel interaction is described by a capillary force profile. Even though ibuprofen is not highly hydrophilic, the relatively smooth surfaces of the crystals allow "contact flooding" upon contact with the steel probe. Capillary forces increase because of the "harvesting" of moisture-due to the fast condensation kinetics-leaving a residual condensate that contributes to increase the interaction force after each consecutive contact. Local asperity contacts on the more hydrophilic surface of the excipients prevent the flooding of the contact zone, and there is no such adhesive effect under the same ambient conditions. The markedly different behavior detected by force measurements clearly shows the sticky and nonsticky propensity of the materials and allows a mechanistic description.
Loscertales, Hèctor R; Wentzky, Valerie; Dürsteler, Kenneth; Strasser, Johannes; Hersberger, Kurt E; Arnet, Isabelle
2017-05-01
Dependence on high-dose benzodiazepines (BZDs) is well known and discontinuation attempts are generally unsuccessful. A well established protocol for high-dose BZD withdrawal management is lacking. We present the case of withdrawal from high-dose lorazepam (>20 mg daily) in an unemployed 35-year-old male outpatient through agonist substitution with long-acting clonazepam and electronic monitoring over 28 weeks. All medicines were repacked into weekly 7 × 4 cavity multidose punch cards with an electronic monitoring system. The prescribed daily dosages of BZDs were translated into an optimal number of daily tablets, divided into up to four units of use. Withdrawal was achieved by individual leftover of a small quantity of BZDs that was placed in a separate compartment. Feedback with visualization of intake over the past week was given during weekly psychosocial sessions. Stepwise reduction was obtained by reducing the mg content of the cavities proportionally to the leftovers, keeping the number of cavities in order to maintain regular intake behavior, and to determine the dosage decrease. At week 28, the primary objectives were achieved, that is, lorazepam reduction to 5 mg daily and cannabis abstinence. Therapy was continued using multidrug punch cards without electronic monitoring to maintain the management system. At week 48, a smaller size weekly pill organizer with detachable daily containers was dispensed. At week 68, the patient's therapy was constant with 1.5 mg clonazepam + 5 mg lorazepam daily for anxiety symptoms and the last steps of withdrawal were started. Several key factors led to successful withdrawal from high-dose BZD in this outpatient, such as the use of weekly punch cards coupled with electronic monitoring, the patient's empowerment over the withdrawal process, and the collaboration of several healthcare professionals. The major implication for clinical care is reduction by following the leftovers, and not a diktat from the healthcare professionals.
NASA Astrophysics Data System (ADS)
Bitner, Rex M.; Koller, Susan C.
2004-06-01
Three different methods of automated high throughput purification of genomic DNA from plant materials processed in 96 well plates are described. One method uses MagneSil paramagnetic particles to purify DNA present in single leaf punch samples or small seed samples, using 320ul capacity 96 well plates which minimizes reagent and plate costs. A second method uses 2.2 ml and 1.2 ml capacity plates and allows the purification of larger amounts of DNA from 5-6 punches of materials or larger amounts of seeds. The third method uses the MagneSil ONE purification system to purify a fixed amount of DNA, thus simplifying the processing of downstream applications by normalizing the amounts of DNA so they do not require quantitation. Protocols for the purification of a fixed yield of DNA, e.g. 1 ug, from plant leaf or seed samples using MagneSil paramagnetic particles and a Beckman-Coulter BioMek FX robot are described. DNA from all three methods is suitable for applications such as PCR, RAPD, STR, READIT SNP analysis, and multiplexed PCR systems. The MagneSil ONE system is also suitable for use with SNP detection systems such as Third Wave Technology"s Invader methods.
1976-09-01
Model AN/ UGC -59A teletype and paper-tape punch console. This unit is connected with the Intellec 8 computer and punching operations are controlled by...order to use this program, the microprocessor would have to be one of the many types on the market that make use of the INTEL 8008-1 CPD chip. The use
Faghihi, Gita; Nouraei, Saeid; Asilian, Ali; Keyvan, Shima; Abtahi-Naeini, Bahareh; Rakhshanpour, Mehrdad; Nilforoushzadeh, Mohammad Ali; Hosseini, Sayed Mohsen
2015-01-01
Background: A number of treatments for reducing the appearance of acne scars are available, but general guidelines for optimizing acne scar treatment do not exist. The aim of this study was to compare the clinical effectiveness and side effects of fractional carbon dioxide (CO2) laser resurfacing combined with punch elevation with fractional CO2 laser resurfacing alone in the treatment of atrophic acne scars. Materials and Methods: Forty-two Iranian subjects (age range 18–55) with Fitzpatrick skin types III to IV and moderate to severe atrophic acne scars on both cheeks received randomized split-face treatments: One side received fractional CO2 laser treatment and the other received one session of punch elevation combined with two sessions of laser fractional CO2 laser treatment, separated by an interval of 1 month. Two dermatologists independently evaluated improvement in acne scars 4 and 16 weeks after the last treatment. Side effects were also recorded after each treatment. Results: The mean ± SD age of patients was 23.4 ± 2.6 years. Clinical improvement of facial acne scarring was assessed by two dermatologists blinded to treatment conditions. No significant difference in evaluation was observed 1 month after treatment (P = 0.56). Their evaluation found that fractional CO2 laser treatment combined with punch elevation had greater efficacy than that with fractional CO2 laser treatment alone, assessed 4 months after treatment (P = 0.02). Among all side effects, coagulated crust formation and pruritus at day 3 after fractional CO2 laser treatment was significant on both treatment sides (P < 0.05). Conclusion: Concurrent use of fractional laser skin resurfacing with punch elevation offers a safe and effective approach for the treatment of acne scarring. PMID:26538695
Zheng, Naiyu; Yuan, Long; Ji, Qin C; Mangus, Heidi; Song, Yan; Frost, Charles; Zeng, Jianing; Aubry, Anne-Françoise; Arnold, Mark E
2015-04-15
Apixaban (Eliquis™) was developed by Bristol-Myers Squibb (BMS) and Pfizer to use as an antithrombotic/anticoagulant agent and has been recently approved for the prevention of stroke and systemic embolism in patients with nonvalvular atrial fibrillation. A clinical study of apixaban, sponsored by BMS and Pfizer, included a pilot exploratory portion to evaluate the potential for future drug concentration monitoring using dried blood spot (DBS) sample collection. For DBS sample collection, a fixed blood volume was dispensed onto a DBS card by either regular volumetric pipette (venous blood collection) or capillary dispenser (finger prick blood collection). A 96-well semi-automated liquid-liquid extraction sample preparation procedure was developed to provide clean extracts for UHPLC-MS/MS quantitation. Assays using both partial-spot center punch and whole spot punch were developed and validated. The linear dynamic ranges for all the analyses were from 0.5 to 500 ng/mL. The coefficient of determination (r(2)) values was >0.9944 for all the validation runs. For the center punch approach, the intra-assay precision (%CV) was within 4.4% and inter-assay precision was within 2.6%. The assay accuracy, expressed as %Dev., was within ± 5.4% of the nominal concentrations. One accuracy and precision run was performed using the whole spot approach, the intra-assay precision (%CV) was within 7.1% and the accuracy was within ± 8.0% of the nominal concentrations. In contrast to the center punch approach, the whole spot approach eliminated the effect of hematocrit and high lipids on the analysis of apixaban in human DBS when an accurate sample blood volume was collected on DBS cards. Copyright © 2015 Elsevier B.V. All rights reserved.
Speer, Henry L.
1973-01-01
The effect of arsenate, arsenite, 2,4-dinitrophenol, and anaerobiosis on early events in seed germination was investigated using both intact and punched seeds of lettuce (Lactuca sativa L.). It was found that punching the seed removes penetration barriers to the entrance of inhibitors without an undue loss of germination or light responses. The kinetics of the action of germination inhibitors were established by 2-hour pulse experiments. Arsenate and 2, 4-dinitrophenol have very different kinetics. The inhibition of germination in punched seeds by arsenate given in conjunction with phosphate compared with the lack of inhibition of arsenate plus phosphate on the growing seedling, suggest a distinct metabolic change in the germinating embryo at some time between the onset of germination and subsequent seedling growth. Images PMID:16658515
Promoting response variability and stimulus generalization in martial arts training.
Harding, Jay W; Wacker, David P; Berg, Wendy K; Rick, Gary; Lee, John F
2004-01-01
The effects of reinforcement and extinction on response variability and stimulus generalization in the punching and kicking techniques of 2 martial arts students were evaluated across drill and sparring conditions. During both conditions, the students were asked to demonstrate different techniques in response to an instructor's punching attack. During baseline, the students received no feedback on their responses in either condition. During the intervention phase, the students received differential reinforcement in the form of instructor feedback for each different punching or kicking technique they performed during a session of the drill condition, but no reinforcement was provided for techniques in the sparring condition. Results showed that both students increased the number of different techniques they performed when reinforcement and extinction procedures were conducted during the drill condition, and that this increase in response variability generalized to the sparring condition. PMID:15293637
Ito, Manabu; Aoki, Shigeru; Uchiyama, Jumpei; Yamato, Keisuke
2018-04-20
Sticking is a common observation in the scale-up stage on the punch tip using a commercial tableting machine. The difference in the total compression time between a laboratory and a commercial tableting machine is considered one of the main root causes of scale up issues in the tableting processes. The proposed Size Adjusted for Scale-up (SAS) punch can be used to adjust the consolidation and dwell times for commercial tableting machine. As a result, the sticking phenomenon is able to be replicated at the pilot scale stage. As reported in this paper, the quantification of sticking was measured using a 3D laser scanning microscope to check the tablet surface. It was shown that the sticking area decreased with the addition of magnesium stearate in the formulation, but the sticking depth was not affected by the additional amount of magnesium stearate. It is proposed that use of a 3D laser scanning microscope can be applied to evaluate sticking as a process analytical technology (PAT) tool and so sticking can be monitored continuously without stopping the machine. Copyright © 2018. Published by Elsevier Inc.
The activity profile of elite male amateur boxing.
Davis, Philip; Benson, Peter R; Pitty, James D; Connorton, Andrew J; Waldock, Robert
2015-01-01
An activity profile of competitive 3 × 3-min elite-level amateur boxing was created from video footage of 29 Olympic final and semifinal bouts in 39 male boxers (mean ± SD) age 25.1 ± 3.6 y, height 178.3 ± 10.4 cm, and body mass 69.7 ± 16.5 kg. Boxing at this level requires the ability to maintain an activity rate of ~1.4 actions/s, consisting of ~20 punches, ~2.5 defensive movements, and ~47 vertical hip movements, all per minute, over 3 subsequent rounds lasting ~200 s each. Winners had higher total punches landed (P = .041) and a lower ratio of punches thrown to landed (P = .027) than losers in round 3. The hook rear-hand landed was also higher for winners than losers in round 2 (P = .038) and round 3 (P = .016), and defensive movements were used less by winners (P = .036). However, the results suggest that technical discrimination between winners and losers is difficult; bout outcome may be more dependent on which punch is "lucky" enough to be scored by the judges or who appears to be dominant on the day. This study gives both boxers and coaches a good idea of where subelite boxers need to aim if they want to become among the best amateur boxers in the world.
2014-07-01
5,9], W [16], Zr [17] and Nb [18]. These systems have shown moderate to extraordinarily high microstructural stability at elevated temperatures...cans were then either serial sectioned for shear punch testing or cut into compression samples using wire electric discharge machining. Through SEM...to resist deformation, but do not necessarily alter the dislocation mechanism operating during plastic deformation. There are a number of challenges
Parastar, Fatemeh; Hejazi, Sayyed Mahdi; Sheikhzadeh, Mohammad; Alirezazadeh, Azam
2017-11-01
Nowadays, the raise of excessive generation of solid wastes is considered as a major environmental concern due to the fast global population growth. The contamination of groundwater from landfill leachate compromises every living creature. Geotextile clay liner (GCL) that has a sandwich structure with two fibrous sheets and a clay core can be considered as an engineered solution to prevent hazardous pollutants from entering into groundwater. The main objective of the present study is therefore to enhance the performance of GCL structures. By changing some structural factors such as clay type (sodium vs. calcium bentonite), areal density of clay, density of geotextile, geotextile thickness, texture type (woven vs. nonwoven), and needle punching density a series of GCL samples were fabricated. Water pressure, type of cover soil and overburden pressure were the environmental variables, while the response variables were hydraulic conductivity and self-healing rate of GCL. Rigid wall constant head permeability test was conducted on all the samples. The outlet water flow was measured and evaluated at a defined time period and the hydraulic conductivity was determined for each sample. In the final stage, self-healing properties of samples were investigated and an analytical model was used to explain the results. It was found that higher Montmorillonite content of clay, overburden pressure, needle punching density and areal density of clay poses better self-healing properties and less hydraulic conductivity, meanwhile, an increase in water pressure increases the hydraulic conductivity. Moreover, the observations were aligned with the analytical model and indicated that higher fiber inclusion as a result of higher needle-punching density produces closer contact between bentonite and fibers, reduces hydraulic conductivity and increases self-healing properties. Copyright © 2017 Elsevier Ltd. All rights reserved.
Dynamic effect in ultrasonic assisted micro-upsetting
NASA Astrophysics Data System (ADS)
Presz, Wojciech
2018-05-01
The use of ultrasonic assistance in microforming is becoming more and more popular. Mainly due to the beneficial effect of vibrations on the flow of plastic deformation reported already in the 50s of the last century. The influence is of two types: surface and volume. The surface effect is mainly the reduction of friction forces, and volumetric is the impact on the dislocation movement and even on phase transitions. The work focuses on the dynamic aspect of vibration assisted microforming. The use of ultrasonic vibrations at a frequency of 20 kHz and an amplitude of 16 µm, in the micro-upsetting process of an aluminum sample resulted in a high concentration of strain on both ends of the sample - at 14% of the height on both sides. There was observed (in relation to deformations of the sample without vibrations) 150-250% increase and a 50% decrease in strain in the center of the sample. At the same time, the larger deformations occurred from the impact side of the punch. Analyzing the course of forces of the upsetting process in the loading and unloading phase as well as the process of breaking glass samples, the spring deflections of key system elements and their natural frequencies were determined or calculated. Based on the determined or calculated parameters of the test stand, it was shown that during the micro-upsetting process the punch may detach from the sample surface and this is the main reason for the phenomena occurring. Detach of the punch is also the cause of the observed instability of the measurement of force, which should be considered unbelievable in such a situation.
ERIC Educational Resources Information Center
Wiseman, Martin; O'Gorman, Shannon
2018-01-01
Queensland has recently seen the first conviction under the new one-punch law. In this instance a then 19-year-old male punched and fatally injured a 54-year-old man. This article details a six session manualised group therapy approach that was applied within a mainstream school in an effort to support adolescents who had been identified as having…
Evaluation of a cleanser for petroleum-contaminated skin.
Phieffer, Laura S; Banks, David M; Bosse, Michael J; Meyer, Martha H; Meyer, Ralph A; Smith, Kevin
2003-12-01
Extremity injuries contaminated with petroleum products pose clinical dilemmas. This project was designed to evaluate the efficacy of a dioctyl sulfosuccinate (DS) solution for cleansing petroleum-contaminated skin. One hundred Sprague-Dawley rats were subjected to a contamination protocol followed by a cleansing procedure. Four petroleum contaminants and five cleansing solutions were selected. The protocol consisted of shaving, initial punch biopsy, contamination, precleansing punch biopsy, standardized scrub protocol, and postcleansing punch biopsy. Biopsy samples were analyzed for petroleum residue using fluorometry. The 10% DS solution had the highest reduction of crude oil, grease, and tar: 99.6 +/- 0.4% (mean +/- SD) contaminant reduction for crude oil, 99.8 +/- 0.2% for grease, and 99.8 +/- 0.2% for tar. The other cleansers showed less efficacy (p < 0.05). Concentrated DS appears to be significantly more effective at cleaning petroleum products from skin than the commonly chosen surgical and commercial cleansers.
Axisymmetric problem of fretting wear for a foundation with a nonuniform coating and rough punch
NASA Astrophysics Data System (ADS)
Manzhirov, A. V.; Kazakov, K. E.
2018-05-01
The axisymmetric contact problem with fretting wear for an elastic foundation with a longitudinally nonuniform (surface nonuniform) coating and a rigid punch with a rough foundation has been solved for the first time. The case of linear wear is considered. The nonuniformity of the coating and punch roughness are described by a different rapidly changing functions. This strong nonuniformity arises when coatings are deposited using modern additive manufacturing technologies. The problem is reduced the solution of an integral equation with two different integral operators: a compact self-adjoint positively defined operator with respect to the coordinate and the non-self-adjoint integral Volterra operator with respect to time. The solution is obtained in series using the projection method of the authors. The efficiency of the proposed approach for constructing a high-accuracy approximate solution to the problem (with only a few expansion terms retained) is demonstrated.
Wu, Li-Wei; Lin, Wen-Jie; Hsu, Yu-Feng
2018-01-01
Abstract The Tailed Punch, Dodona eugenes, is widely distributed in East Asia with seven subspecies currently recognized. However, two of them, namely ssp. formosana and ssp. esakii found in Taiwan, are hard to distinguish from each other due to ambiguous diagnostic characters. In this study, their taxonomic status is clarified by comparing genitalia characters and phylogenetic relationships based on mitochondrial sequences, COI and COII (total 2211 bps). Our results show that there is no reliable feature to separate these two subspecies. Surprisingly we found that Dodona in Taiwan is more closely related to the Orange Punch, D. egeon, than to other subspecies of D. eugenes. Therefore, the following nomenclatural changes are proposed: Dodona eugenes formosana is revised to specific status as Dodona formosana Matsumura, 1919, stat. rev, and ssp. esakii is sunk to a junior synonym of Dodona formosana syn. n. PMID:29674868
Aminzahed, Iman; Mashhadi, Mahmoud Mosavi; Sereshk, Mohammad Reza Vaziri
2017-02-01
Micro forming is a manufacturing process to fabricate micro parts with high quality and a cost effective manner. Deep drawing could be a favorable method for production of complicated parts in macro and micro sizes. In this paper piezoelectric actuator is used as a novel approach in the field of micro manufacturing. Also, in current work, investigations are conducted with four rectangular punches and blanks with various thicknesses. Blank holder pressure effects on thickness distributions, punch force, and springback are studied. According to the results of this work, increasing of blank holder pressure in scaled deep drawing, in contrast to thickness of drawn part, leads to decrease in the punch forces and springback. Furthermore, it is shown that in micro deep drawing, the effects of holder pressure on mentioned parameters can be ignored. Copyright © 2016 Elsevier B.V. All rights reserved.
Improvement of formability of high strength steel sheets in shrink flanging
NASA Astrophysics Data System (ADS)
Hamedon, Z.; Abe, Y.; Mori, K.
2016-02-01
In the shrinkage flanging, the wrinkling tends to occur due to compressive stress. The wrinkling will cause a difficulty in assembling parts, and severe wrinkling may leads to rupture of parts. The shrinkage flange of the ultra-high strength steel sheets not only defects the product by the occurrence of the wrinkling but also causes seizure and wear of the dies and shortens the life of dies. In the present study, a shape of a punch having gradual contact was optimized in order to prevent the wrinkling in shrinkage flanging of ultra-high strength steel sheets. The sheet was gradually bent from the corner of the sheet to reduce the compressive stress. The wrinkling in the shrink flanging of the ultra-high strength steel sheets was prevented by the punch having gradual contact. It was found that the punch having gradual contact is effective in preventing the occurrence of wrinkling in the shrinkage flanging.
Blanking and piercing theory, applications and recent experimental results
NASA Astrophysics Data System (ADS)
Zaid, Adnan l. O.
2014-06-01
Blanking and piercing are manufacturing processes by which certain geometrical shapes are sheared off a sheet metal. If the sheared off part is the one required, the processes referred to as blanking and if the remaining part in the sheet is the one required, the process is referred to as piercing. In this paper, the theory and practice of these processes are reviewed and discussed The main parameters affecting these processes are presented and discussed. These include: the radial clearance percentage, punch and die geometrical parameters, for example punch and die profile radii. The abovementioned parameters on the force and energy required to effect blanking together with their effect on the quality of the products are also presented and discussed. Recent experimental results together with photomacrographs and photomicrographs are also included and discussed. Finally, the effect of punch and die wear on the quality of the blanks is alsogiven and discussed.
Laffer, Matthew; Ackerman, Lindsay
2018-01-01
A 23-year-old man presented with new-onset pruritic and painful urticarial lesions and targetoid erythematous plaques on both palms, the trunk, and the upper and lower extremities (Figure 1). Additionally, small pustules were discovered on the neck (Figure 2), and there with edematous erythematous vermillion lips with splaying onto the cutaneous lips without ulceration. The patient stated he had had a fever before the eruption, fatigue, chills, myalgias, and sore throat. A chest x-ray was obtained and showed bilateral infiltrates. Two 4-mm punch biopsies were performed on the left forearm and left side of the neck; a resulting section from the left forearm is shown in Figure 3.
A Case of Infantile Kyrle-Flegel Disease in a 6-Year-Old Yemeni Girl.
Alshami, Mohammad Ali; Mohana, Mona Jameel
2016-01-01
Kyrle disease (KD) and Flegel disease (FD) are rare variants of primary perforating dermatoses, characterized by transepidermal elimination of abnormal endogenous materials. We describe a 6-year-old Yemeni girl with a 2-year history of generalized asymptomatic, small, reddish-brown keratotic papules with a lenticular central keratotic plug. Although these features are synonymous with FD, the histology of a punch biopsy was consistent with KD. The patient was otherwise healthy, and no family members had a history of similar diseases. The patient was diagnosed with KD-FD, owing to the manifestation of features associated with both diseases.
A Case of Infantile Kyrle-Flegel Disease in a 6-Year-Old Yemeni Girl
Alshami, Mohammad Ali; Mohana, Mona Jameel
2016-01-01
Kyrle disease (KD) and Flegel disease (FD) are rare variants of primary perforating dermatoses, characterized by transepidermal elimination of abnormal endogenous materials. We describe a 6-year-old Yemeni girl with a 2-year history of generalized asymptomatic, small, reddish-brown keratotic papules with a lenticular central keratotic plug. Although these features are synonymous with FD, the histology of a punch biopsy was consistent with KD. The patient was otherwise healthy, and no family members had a history of similar diseases. The patient was diagnosed with KD-FD, owing to the manifestation of features associated with both diseases. PMID:26933407
Computer aided system for parametric design of combination die
NASA Astrophysics Data System (ADS)
Naranje, Vishal G.; Hussein, H. M. A.; Kumar, S.
2017-09-01
In this paper, a computer aided system for parametric design of combination dies is presented. The system is developed using knowledge based system technique of artificial intelligence. The system is capable to design combination dies for production of sheet metal parts having punching and cupping operations. The system is coded in Visual Basic and interfaced with AutoCAD software. The low cost of the proposed system will help die designers of small and medium scale sheet metal industries for design of combination dies for similar type of products. The proposed system is capable to reduce design time and efforts of die designers for design of combination dies.
High Temperature Deformation Mechanisms in a DLD Nickel Superalloy
Davies, Sean; Jeffs, Spencer; Lancaster, Robert; Baxter, Gavin
2017-01-01
The realisation of employing Additive Layer Manufacturing (ALM) technologies to produce components in the aerospace industry is significantly increasing. This can be attributed to their ability to offer the near-net shape fabrication of fully dense components with a high potential for geometrical optimisation, all of which contribute to subsequent reductions in material wastage and component weight. However, the influence of this manufacturing route on the properties of aerospace alloys must first be fully understood before being actively applied in-service. Specimens from the nickel superalloy C263 have been manufactured using Powder Bed Direct Laser Deposition (PB-DLD), each with unique post-processing conditions. These variables include two build orientations, vertical and horizontal, and two different heat treatments. The effects of build orientation and post-process heat treatments on the materials’ mechanical properties have been assessed with the Small Punch Tensile (SPT) test technique, a practical test method given the limited availability of PB-DLD consolidated material. SPT testing was also conducted on a cast C263 variant to compare with PB-DLD derivatives. At both room and elevated temperature conditions, differences in mechanical performances arose between each material variant. This was found to be instigated by microstructural variations exposed through microscopic and Energy Dispersive X-ray Spectroscopy (EDS) analysis. SPT results were also compared with available uniaxial tensile data in terms of SPT peak and yield load against uniaxial ultimate tensile and yield strength. PMID:28772817
ERIC Educational Resources Information Center
Bingul, Bergun Meric; Bulgun, Cigdem; Tore, Ozlem; Bal, Erdal; Aydin, Mensure
2018-01-01
The aim of this study was to investigate the effects of biomechanic factors to teach different hook punches in boxing. Eight light middleweight boxing athletes (mean age ± SD 19.00 ± 2.00 yrs, mean height ± SD 173.88 ± 3.89 cm, mean weight ± SD 64.25 ± 4.66 kg) participated in this study. Athletes performed a trial using three different hook punch…
NASA Astrophysics Data System (ADS)
Panicker, Sudhy S.; Singh, Har Govind; Panda, Sushanta Kumar; Dashwood, Richard
2015-11-01
Automotive industries are very much interested in characterization of formability improvement of aluminum alloys at elevated temperatures before designing tools, heating systems, and processing sequences for fabrication of auto-body panels by warm forming technology. In this study, tensile tests of AA5754-H22 aluminum alloy were carried out at five different temperatures and three different strain rates to investigate the deformation behavior correlating with Cowper-Symonds constitutive equation. Laboratory scale warm forming facilities were designed and fabricated to perform limiting dome height and deep drawing tests to evaluate forming limit strains and drawability of sheet metal at different tool temperatures. The forming limit strain and dome height improved significantly when both the die and punch were heated to 200 °C. Remarkable improvement in deep drawn cup depth was observed when die and punch temperatures were maintained at 200 and 30 °C, respectively, producing a non-isothermal temperature gradient of approximately 93 °C across the blank from flange to center. The forming behavior at different isothermal and non-isothermal conditions were predicted successfully using a thermo-mechanical FE model incorporating temperature-dependent properties in Barlat-89 yield criterion coupled with Cowper-Symonds hardening model, and the thinning/failure location in deformed cups were validated implementing the experimental limiting strains as damage model.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lawrence, J.D.
1970-03-12
The Control Data 405 card reader, modified by the Control Data 3649 card read controller, is the primary mechanism for transferring information from a deck of punched cards into the CDC 6600 and CDC 7600 computers of the LLL Octopus system. The card reader operates at a maximum rate of 1200 cards per minute. A description of the card reader and its operation is given. A discussion of formates is included. (RWR)
Blakeman, J. M.
1983-01-01
The skin punch biopsy is a simple and safe office procedure which is a valuable aid in diagnosing many skin diseases. It can be performed in a few minutes and offers in most situations a very suitable histological specimen with a minimum amount of scarring and little or no pain or discomfort to the patient. The indications for skin biopsy, selection of a proper site and the technique are described. ImagesFig. 1Fig. 2Fig. 3Fig. 4Fig. 5Fig. 6Fig. 7 PMID:21283375
Damage Accumulation in Advanced Metal Matrix Composites Under Thermal Cycling/Creep Loadings
1993-09-01
34transformation strain" (Eshelby, 1957) or * eigenstrain " (Mura, 1987). The stress-strain relation of a ccmposite predicted by the Tanaka-Mori model is given by a0o...a short fiber MMC can be calculated if the following eigenstrains are given in the domains of fiber (0l) and of the punched region encompassing the...and Mortenson modified the above model to account for partial relaxation by dislocation punching along the fiber axis. The eigenstrains based on this
Space Shuttle stability and control test plan
NASA Technical Reports Server (NTRS)
Cooke, D. R.
1982-01-01
The development of a completely automatic flight test program to test different aspects of the Shuttle flight capability during reentries is described. Data from each flight to date has been employed to devise a sequence of maneuvers which will be keyboard-punched into the Orbiter control system by the astronauts during entry phases of flight. Details of the interaction and cooperation of the Orbiter elevons and bodyflap to provide the vehicle with latitudinal and longitudinal directional control and trim are outlined. Uncertainties predicted for the control of the Orbiter during wind tunnel testing prior to actual flights have been adjusted to actual flight data, leading to the identification of actual flight regimes which need further investigation. Maneuvers scheduled for flights 5-9 are reviewed.
Proton irradiation damage of an annealed Alloy 718 beam window
Bach, H. T.; Anderoglu, O.; Saleh, T. A.; ...
2015-04-01
Mechanical testing and microstructural analysis was performed on an Alloy 718 window that was in use at the Los Alamos Neutron Science Center (LANSCE) Isotope Production Facility (IPF) for approximately 5 years. It was replaced as part of the IPF preventive maintenance program. The window was transported to the Wing 9 hot cells at the Chemical and Metallurgical Research (CMR) LANL facility, visually inspected and 3-mm diameter samples were trepanned from the window for mechanical testing and microstructural analysis. Shear punch testing and optical metallography was performed at the CMR hot cells. The 1-mm diameter shear punch disks were cutmore » into smaller samples to further reduce radiation exposure dose rate using Focus Ion Beam (FIB) and microstructure changes were analyzed using a Transmission Electron Microscopy (TEM). Irradiation doses were determined to be ~0.2–0.7 dpa (edge) to 11.3 dpa (peak of beam intensity) using autoradiography and MCNPX calculations. The corresponding irradiation temperatures were calculated to be ~34–120 °C with short excursion to be ~47–220 °C using ANSYS. Mechanical properties and microstructure analysis results with respect to calculated dpa and temperatures show that significant work hardening occurs but useful ductility still remains. The hardening in the lowest dose region (~0.2–0.7 dpa) was the highest and attributed to the formation of γ" precipitates and irradiation defect clusters/bubbles whereas the hardening in the highest dose region (~11.3 dpa) was lower and attributed mainly to irradiation defect clusters and some thermal annealing.« less
1951-08-17
Phenolic Phenolic Phenolic Phe-nolle Genera^.’ General General Electrical Electrical! Punching Mechanical General Electrical Fine Machin ...spores» The resulting separate suspensions were mixed to obtain a composite : spore suspension ~för"üse in inocüla ting the test specimens© 79...7 {SQKT33SI3SDJ fltttg*.8..«t.J56 FÜtfOOS BIBlSTikÄ C£ HäST’Iö LAMINATS (EüHigjiTy EXBöSTJSB; METHOD JL-.-- Ör&ie 5 - 11G
1976-03-01
and output is presently via a teletypewriter keyboard and paper-tape punch. A direct interface with the Hewlett-Packard HP 983OA calculator is a logical...Hewlett-Packard HP 9830A calculator is a logical modification of the systsi. CONTENTS I INTRODUCTION 12 II MIDAS 17 DATA ACQUISITDN AND CONTROL SYSTEM...interface with the Hewlett -Packard Model 9830 A calculator system for data reduction and presentation. The design of the system was initiated K v It. J. W
2014-03-27
created using a hammer and a punch tool provided by Material Test Systems (MTS) and were kept to a minimal depth to avoid fracture initiation at the...temperature. 76 be seen that the modulus remains relatively constant until near failure. There was no apparent correlation between modulus loss and...Normalized modulus vs. fatigue cycles of all ±45° specimens can be seen in Figure 56. There is not an evident correlation between number of cycles and
A method of lead determination in human teeth by energy dispersive X-ray fluorescence (EDXRF).
Sargentini-Maier, M L; Frank, R M; Leroy, M J; Turlot, J C
1988-12-01
A systematic sampling procedure was combined with a method of energy dispersive X-ray fluorescence (EDXRF) to study lead content and its variations in human teeth. On serial ground sections made on unembedded permanent teeth of inhabitants of Strasbourg with a special diamond rotating disk, 2 series of 500 microns large punch biopsies were made systematically in 5 directions from the tooth surface to the inner pulpal dentine with a micro-punching unit. In addition, pooled fragments of enamel and dentine were made for each tooth. On each punched fragment or pooled sample, lead content was determined after dissolution in ultrapure nitric acid, on a 4 microns thick polypropylene film, and irradiation with a Siemens EDXRF prototype with direct sample excitation by a high power X-ray tube with a molybdenum anode. Fluorescence was detected by a Si(Li) detector and calcium was used as an internal standard. This technique allowed a rapid, automatic, multielementary and non-destructive analysis of microsamples with good detection limits.
NASA Astrophysics Data System (ADS)
Abdullah, A. B.; Zain, M. S. M.; Abdullah, M. S.; Samad, Z.
2017-07-01
Structural materials, such as composite panels, must be assembled, and such panels are typically constructed via the insertion of a fastener through a drilled hole. The main problem encountered in drilling is delamination, which affects assembly strength. The cost of drilling is also high because of the severe wear on drill bits. The main goal of this research is to develop a new punching method as an alternative to drilling during hole preparation. In this study, the main objective is to investigate the effect of different puncher profiles on the quality of holes punched into carbon fiber reinforcement polymer (CFRP) composite panels. Six types of puncher profiles were fabricated with minimum die clearance (1%), and two quality aspects, namely, incomplete shearing and delamination factor, were measured. The conical puncher incurred the least defects in terms of delamination and yielded an acceptable amount of incomplete shearing in comparison with the other punchers.
Water Potential in Excised Leaf Tissue
Nelsen, Charles E.; Safir, Gene R.; Hanson, Andrew D.
1978-01-01
Leaf water potential (Ψleaf) determinations were made on excised leaf samples using a commercial dew point hygrometer (Wescor Inc., Logan, Utah) and a thermocouple psychrometer operated in the isopiestic mode. With soybean leaves (Glycine max L.), there was good agreement between instruments; equilibration times were 2 to 3 hours. With cereals (Triticum aestivum L. and Hordeum vulgare L.), agreement between instruments was poor for moderately wilted leaves when 7-mm-diameter punches were used in the hygrometer and 20-mm slices were used in the psychrometer, because the Ψleaf values from the dew point hygrometer were too high. Agreement was improved by replacing the 7-mm punch samples in the hygrometer by 13-mm slices, which had a lower cut edge to volume ratio. Equilibration times for cereals were normally 6 to 8 hours. Spuriously high Ψleaf values obtained with 7-mm leaf punches may be associated with the ion release and reabsorption that occur upon tissue excision; such errors evidently depend both on the species and on tissue water status. PMID:16660227
NASA Astrophysics Data System (ADS)
Li, Xin; Zhao, Zhi-Jun; Park, Sang-Hu
2016-07-01
This study demonstrates a simple and flexible out-of-plane induced mechanical stretching method for generating labyrinthic, waving, and straight orderly microscale directional wrinkles. Different complex wrinkling patterns were fabricated simultaneously using a UV-curable thin layer of resin NOA-68T that was coated on a soft foundation. Then an out-of-plane pre-straining deformation was applied by a specially designed punch to generate internal elastic instabilities. The surface wrinkling pattern characteristics (shapes and size) changed according to the amount of punch stroke (pre-strain) and the cross-sectional shape of the punch. This study confirms the usefulness of this method for controlling and generating local wrinkling patterns for diverse applications. As an example, the contact angles of a water droplet on a local area of the same pattern were measured to identify the change in wettability with respect to different wrinkling shapes. This method can be utilized in topographical tunable wrinkle fabrication for local surface modification.
A fat-derived metabolite regulates a peptidergic feeding circuit in Drosophila
Jung, Sung-Hwan; Kim, Young-Joon
2017-01-01
Here, we show that the enzymatic cofactor tetrahydrobiopterin (BH4) inhibits feeding in Drosophila. BH4 biosynthesis requires the sequential action of the conserved enzymes Punch, Purple, and Sepiapterin Reductase (Sptr). Although we observe increased feeding upon loss of Punch and Purple in the adult fat body, loss of Sptr must occur in the brain. We found Sptr expression is required in four adult neurons that express neuropeptide F (NPF), the fly homologue of the vertebrate appetite regulator neuropeptide Y (NPY). As expected, feeding flies BH4 rescues the loss of Punch and Purple in the fat body and the loss of Sptr in NPF neurons. Mechanistically, we found BH4 deficiency reduces NPF staining, likely by promoting its release, while excess BH4 increases NPF accumulation without altering its expression. We thus show that, because of its physically distributed biosynthesis, BH4 acts as a fat-derived signal that induces satiety by inhibiting the activity of the NPF neurons. PMID:28350856
Hair-follicle Transplant Into Chronic Ulcers: A New Graft Concept.
Martínez Martínez, M L; Escario Travesedo, E; Jiménez Acosta, F
Chronic venous leg ulcers are a major therapeutic challenge in clinical practice, and the search for new approaches to improve wound healing is essential. Many ulcers do not heal with traditional treatment using compression, debridement, and dressings. Skin-grafts variants, such as pinch grafts, punch grafts, split- or full-thickness skin grafts, and grafts derived from cells cultured in the laboratory, are among the most widely used options in ulcers that do not heal. In recent years, numerous studies have brought to our attention the important role of the hair follicle in the healing process of cutaneous wounds. Putting knowledge into practice, hair follicles from the scalp have been used in punch-type grafts transplanted to the base of chronic ulcers to stimulate healing. Results appear to be better than those with traditional hairless punch grafts, opening new lines of treatment for recalcitrant chronic venous ulcers. Copyright © 2017 AEDV. Publicado por Elsevier España, S.L.U. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ko, Young Ho; Han, Myoung Soo; Han, Jong Man
2007-05-17
Doubly curved thick plate forming in shipbuilding industries is currently performed by a thermal forming process, called as Line Heating by using gas flame torches. Due to the empirical manual work of it, the industries are eager for an alternative way to manufacture curved thick plates for ships. It was envisaged in this study to manufacture doubly curved thick plates by the multi-punch die forming. Experiments and finite element analyses were conducted to evaluate the feasibility of the reconfigurable discrete die forming to the thick plates. Single and segmented multiple step forming procedures were considered from both forming efficiency andmore » accuracy. Configuration of the multi-punch dies suitable for the segmented multiple step forming was also explored. As a result, Segmented multiple step forming with matched dies had a limited formability when the objective shapes become complicate, while a unmatched die configuration provided better possibility to manufacture large curved plates for ships.« less
NASA Astrophysics Data System (ADS)
Li, Qiang; Argatov, Ivan; Popov, Valentin L.
2018-04-01
A recent paper by Popov, Pohrt and Li (PPL) in Friction investigated adhesive contacts of flat indenters in unusual shapes using numerical, analytical and experimental methods. Based on that paper, we analyze some special cases for which analytical solutions are known. As in the PPL paper, we consider adhesive contact in the Johnson-Kendall-Roberts approximation. Depending on the energy balance, different upper and lower estimates are obtained in terms of certain integral characteristics of the contact area. The special cases of an elliptical punch as well as a system of two circular punches are considered. Theoretical estimations for the first critical force (force at which the detachment process begins) are confirmed by numerical simulations using the adhesive boundary element method. It is shown that simpler approximations for the pull-off force, based both on the Holm radius of contact and the contact area, substantially overestimate the maximum adhesive force.
Punched belt hole position deviation analysis of float type water level gauge
NASA Astrophysics Data System (ADS)
Mao, Chunlei; Wang, Tao; Fu, Weijie; Li, Lianhui
2018-03-01
The key parts of the float type water level gauge instrument is perforated belt, The size and tolerance requirements of its aperture is: (1) alternation of 100+0.2 and 100-0.2, (2) 200±0.1, (3) 1000±0.15, (4) 10000±0.2. The single hole position: alternation of 100+0.2 and 100-0.2; double: 200±0.1, and ensure the best hole position error avoidance tends to be one-way, that is to say: when the punched belt combined with a water wheel rotating line moving, The hole position error to single direction increase or decrease, caused the water level nail gradually and close to the edge of the hole, and then edge and final punched belt was lifted. This paper uses the laser drilling process of steel strip for data collection and analysis. It is found that this method cannot meet the tolerance requirements and the double stamping processing method with adjustable cylindrical pin is feasible.
Stiffness of frictional contact of dissimilar elastic solids
Lee, Jin Haeng; Gao, Yanfei; Bower, Allan F.; ...
2017-12-22
The classic Sneddon relationship between the normal contact stiffness and the contact size is valid for axisymmetric, frictionless contact, in which the two contacting solids are approximated by elastic half-spaces. Deviation from this result critically affects the accuracy of the load and displacement sensing nanoindentation techniques. This study gives a thorough numerical and analytical investigation of corrections needed to the Sneddon solution when finite Coulomb friction exists between an elastic half-space and a flat-ended rigid punch with circular or noncircular shape. Because of linearity of the Coulomb friction, the correction factor is found to be a function of the frictionmore » coefficient, Poisson's ratio, and the contact shape, but independent of the contact size. Two issues are of primary concern in the finite element simulations – adequacy of the mesh near the contact edge and the friction implementation methodology. Although the stick or slip zone sizes are quite different from the penalty or Lagrangian methods, the calculated contact stiffnesses are almost the same and may be considerably larger than those in Sneddon's solution. For circular punch contact, the numerical solutions agree remarkably well with a previous analytical solution. For non-circular punch contact, the results can be represented using the equivalence between the contact problem and bi-material fracture mechanics. Finally, the correction factor is found to be a product of that for the circular contact and a multiplicative factor that depends only on the shape of the punch but not on the friction coefficient or Poisson's ratio.« less
Stiffness of frictional contact of dissimilar elastic solids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Jin Haeng; Gao, Yanfei; Bower, Allan F.
The classic Sneddon relationship between the normal contact stiffness and the contact size is valid for axisymmetric, frictionless contact, in which the two contacting solids are approximated by elastic half-spaces. Deviation from this result critically affects the accuracy of the load and displacement sensing nanoindentation techniques. This study gives a thorough numerical and analytical investigation of corrections needed to the Sneddon solution when finite Coulomb friction exists between an elastic half-space and a flat-ended rigid punch with circular or noncircular shape. Because of linearity of the Coulomb friction, the correction factor is found to be a function of the frictionmore » coefficient, Poisson's ratio, and the contact shape, but independent of the contact size. Two issues are of primary concern in the finite element simulations – adequacy of the mesh near the contact edge and the friction implementation methodology. Although the stick or slip zone sizes are quite different from the penalty or Lagrangian methods, the calculated contact stiffnesses are almost the same and may be considerably larger than those in Sneddon's solution. For circular punch contact, the numerical solutions agree remarkably well with a previous analytical solution. For non-circular punch contact, the results can be represented using the equivalence between the contact problem and bi-material fracture mechanics. Finally, the correction factor is found to be a product of that for the circular contact and a multiplicative factor that depends only on the shape of the punch but not on the friction coefficient or Poisson's ratio.« less
Stiffness of frictional contact of dissimilar elastic solids
NASA Astrophysics Data System (ADS)
Lee, Jin Haeng; Gao, Yanfei; Bower, Allan F.; Xu, Haitao; Pharr, George M.
2018-03-01
The classic Sneddon relationship between the normal contact stiffness and the contact size is valid for axisymmetric, frictionless contact, in which the two contacting solids are approximated by elastic half-spaces. Deviation from this result critically affects the accuracy of the load and displacement sensing nanoindentation techniques. This paper gives a thorough numerical and analytical investigation of corrections needed to the Sneddon solution when finite Coulomb friction exists between an elastic half-space and a flat-ended rigid punch with circular or noncircular shape. Because of linearity of the Coulomb friction, the correction factor is found to be a function of the friction coefficient, Poisson's ratio, and the contact shape, but independent of the contact size. Two issues are of primary concern in the finite element simulations - adequacy of the mesh near the contact edge and the friction implementation methodology. Although the stick or slip zone sizes are quite different from the penalty or Lagrangian methods, the calculated contact stiffnesses are almost the same and may be considerably larger than those in Sneddon's solution. For circular punch contact, the numerical solutions agree remarkably well with a previous analytical solution. For non-circular punch contact, the results can be represented using the equivalence between the contact problem and bi-material fracture mechanics. The correction factor is found to be a product of that for the circular contact and a multiplicative factor that depends only on the shape of the punch but not on the friction coefficient or Poisson's ratio.
Using Teamcenter engineering software for a successive punching tool lifecycle management
NASA Astrophysics Data System (ADS)
Blaga, F.; Pele, A.-V.; Stǎnǎşel, I.; Buidoş, T.; Hule, V.
2015-11-01
The paper presents studies and researches results of the implementation of Teamcenter (TC) integrated management of a product lifecycle, in a virtual enterprise. The results are able to be implemented also in a real enterprise. The product was considered a successive punching and cutting tool, designed to materialize a metal sheet part. The paper defines the technical documentation flow (flow of information) in the process of constructive computer aided design of the tool. After the design phase is completed a list of parts is generated containing standard or manufactured components (BOM, Bill of Materials). The BOM may be exported to MS Excel (.xls) format and can be transferred to other departments of the company in order to supply the necessary materials and resources to achieve the final product. This paper describes the procedure to modify or change certain dimensions of sheet metal part obtained by punching. After 3D and 2D design, the digital prototype of punching tool moves to following lifecycle phase of the manufacturing process. For each operation of the technological process the corresponding phases are described in detail. Teamcenter enables to describe manufacturing company structure, underlying workstations that carry out various operations of manufacturing process. The paper revealed that the implementation of Teamcenter PDM in a company, improves efficiency of managing product information, eliminating time working with search, verification and correction of documentation, while ensuring the uniqueness and completeness of the product data.
Confocal and dermoscopic features of basal cell carcinoma in Gorlin-Goltz syndrome: A case report.
Casari, Alice; Argenziano, Giuseppe; Moscarella, Elvira; Lallas, Aimilios; Longo, Caterina
2017-05-01
Gorlin-Goltz (GS) syndrome is an autosomal dominant disease linked to a mutation in the PTCH gene. Major criteria include the onset of multiple basal cell carcinoma (BCC), keratocystic odontogenic tumours in the jaws and bifid ribs. Dermoscopy and reflectance confocal microscopy represent imaging tools that are able to increase the diagnostic accuracy of skin cancer in a totally noninvasive manner, without performing punch biopsies. Here we present a case of a young woman in whom the combined approach of dermoscopy and RCM led to the identification of multiple small inconspicuous lesions as BCC and thus to the diagnosis of GS syndrome. © 2016 The Australasian College of Dermatologists.
Hole punch clouds over the Bahamas
2017-12-08
In elementary school, students learn that water freezes at 0 degrees Celsius (32 degrees Fahrenheit). That is true most of the time, but there are exceptions to the rule. For instance, water with very few impurities (such as dust or pollution particles, fungal spores, bacteria) can be chilled to much cooler temperatures and still remain liquid—a process known as supercooling. Supercooling may sound exotic, but it occurs pretty routinely in Earth’s atmosphere. Altocumulus clouds, a common type of mid-altitude cloud, are mostly composed of water droplets supercooled to a temperature of about -15 degrees C. Altocumulus clouds with supercooled tops cover about 8 percent of Earth’s surface at any given time. Supercooled water droplets play a key role in the formation of hole-punch and canal clouds, the distinctive clouds shown in these satellite images. Hole-punch clouds usually appear as circular gaps in decks of altocumulus clouds; canal clouds look similar but the gaps are longer and thinner. This true-color image shows hole-punch and canal clouds off the coast of Florida, as observed on December 12, 2014, by the Moderate Resolution Imaging Spectroradiometer (MODIS) on NASA’s Terra satellite. Both types of cloud form when aircraft fly through cloud decks rich with supercooled water droplets and produce aerodynamic contrails. Air expands and cools as it moves around the wings and past the propeller, a process known as adiabatic cooling. Air temperatures over jet wings often cool by as much as 20 degrees Celsius, pushing supercooled water droplets to the point of freezing. As ice crystals form, they absorb nearby water droplets. Since ice crystals are relatively heavy, they tend to sink. This triggers tiny bursts of snow or rain that leave gaps in the cloud cover. Whether a cloud formation becomes a hole-punch or canal depends on the thickness of the cloud layer, the air temperature, and the degree of horizontal wind shear. Both descending and ascending aircraft—including jets and propeller planes—can trigger hole-punch and canal clouds. The nearest major airports in the images above include Miami International, Fort Lauderdale International, Grand Bahama International, and Palm Beach International. Credit: NASA/GSFC/Jeff Schmaltz/MODIS Land Rapid Response Team NASA image use policy. NASA Goddard Space Flight Center enables NASA’s mission through four scientific endeavors: Earth Science, Heliophysics, Solar System Exploration, and Astrophysics. Goddard plays a leading role in NASA’s accomplishments by contributing compelling scientific knowledge to advance the Agency’s mission. Follow us on Twitter Like us on Facebook Find us on Instagram
NASA Astrophysics Data System (ADS)
Mohan, Nisha
Compliant foams are usually characterized by a wide range of desirable mechanical properties. These properties include viscoelasticity at different temperatures, energy absorption, recoverability under cyclic loading, impact resistance, and thermal, electrical, acoustic and radiation-resistance. Some foams contain nano-sized features and are used in small-scale devices. This implies that the characteristic dimensions of foams span multiple length scales, rendering modeling their mechanical properties difficult. Continuum mechanics-based models capture some salient experimental features like the linear elastic regime, followed by non-linear plateau stress regime. However, they lack mesostructural physical details. This makes them incapable of accurately predicting local peaks in stress and strain distributions, which significantly affect the deformation paths. Atomistic methods are capable of capturing the physical origins of deformation at smaller scales, but suffer from impractical computational intensity. Capturing deformation at the so-called meso-scale, which is capable of describing the phenomenon at a continuum level, but with some physical insights, requires developing new theoretical approaches. A fundamental question that motivates the modeling of foams is `how to extract the intrinsic material response from simple mechanical test data, such as stress vs. strain response?' A 3D model was developed to simulate the mechanical response of foam-type materials. The novelty of this model includes unique features such as the hardening-softening-hardening material response, strain rate-dependence, and plastically compressible solids with plastic non-normality. Suggestive links from atomistic simulations of foams were borrowed to formulate a physically informed hardening material input function. Motivated by a model that qualitatively captured the response of foam-type vertically aligned carbon nanotube (VACNT) pillars under uniaxial compression [2011,"Analysis of Uniaxial Compression of Vertically Aligned Carbon Nanotubes," J. Mech.Phys. Solids, 59, pp. 2227--2237, Erratum 60, 1753-1756 (2012)], the property space exploration was advanced to three types of simple mechanical tests: 1) uniaxial compression, 2) uniaxial tension, and 3) nanoindentation with a conical and a flat-punch tip. The simulations attempt to explain some of the salient features in experimental data, like 1) The initial linear elastic response. 2) One or more nonlinear instabilities, yielding, and hardening. The model-inherent relationships between the material properties and the overall stress-strain behavior were validated against the available experimental data. The material properties include the gradient in stiffness along the height, plastic and elastic compressibility, and hardening. Each of these tests was evaluated in terms of their efficiency in extracting material properties. The uniaxial simulation results proved to be a combination of structural and material influences. Out of all deformation paths, flat-punch indentation proved to be superior since it is the most sensitive in capturing the material properties.
Sierra Hotel: Flying Air Force Fighters in the Decade After Vietnam
2001-01-01
intake in the front, and two rear missiles on the aft belly stations. Each missile had an ejector foot that kicked the missile away from the aircraft...bar, often dragging a thrower or two along with him. The more dangerous the game, the better, and Sockey, a hybrid of soccer and hockey, was the most...When the LGB kits were added to the 2,000-pound ver- sion, they added a tremendous punch, but the biggest punch of all came from “ Fat Albert,” a 3,000
Technique for controlling shrinkage distortion in cold-pressed annular pellets
Johnson, R.G.R.; Burke, T.J.
1982-06-28
A process and apparatus are described for the production of annular fuel pellets comprising locating particulate fuel material in a compaction chamber having side walls, a moveable punch located opposite a fixed member and a frustoconical element having a taper of between about 0.010 to 0.015 inches/inch located in about the center of the chamber. The punch is moved toward the fixed surface to compact the particulate material. The compacted pellet is fired to produce sintered pellets having substantially straight inner side walls essentially parallel to the pellet axis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, J.S.; Institute of Advanced Energy, Kyoto University, Gokasho, Uji, Kyoto 611-0011; Kim, I.S.
2004-07-01
The degradation of mechanical properties in dual phase 309L stainless steel RPV clad caused by the presence of s-phase as well as neutron irradiation was investigated using a small punch (SP) test. Two kinds of overlay-weld clad were fabricated on SA508 cl.3 pressure vessel steel plates with ER309L welding consumable strip by differing in heat input rates. The microstructure of the clad was composed of a main part of fcc austenite, a few percent of bcc d- ferrite and brittle bct s-phase. Area fraction of s-phase was ranging approximately 2 {approx} 8 percent depending on welding conditions. The JMTR wasmore » utilized for neutron irradiation and SP specimens were irradiated up to 1.02 x 10{sup 19} n/cm{sup 2} (E>1 MeV) at 563 K. After irradiation the SP ductile-to-brittle transition behavior moved to higher temperatures, however, it was more strongly affected by the amount of brittle s-phase rather than the irradiation at current doses. The cracking appearances in the SP specimens gradually changed from circumferential to radial cracking as the test temperature became low, content of {sigma}-phase increased and the specimens were irradiated. Those results were accounted for in terms of the inconsistency of fracture stress between the phases as well as the effects of stress-strain portioning combined with the changes of governing stress components for crack initiation. (authors)« less
Elastic layer under axisymmetric indentation and surface energy effects
NASA Astrophysics Data System (ADS)
Intarit, Pong-in; Senjuntichai, Teerapong; Rungamornrat, Jaroon
2018-04-01
In this paper, a continuum-based approach is adopted to investigate the contact problem of an elastic layer with finite thickness and rigid base subjected to axisymmetric indentation with the consideration of surface energy effects. A complete Gurtin-Murdoch surface elasticity is employed to consider the influence of surface stresses. The indentation problem of a rigid frictionless punch with arbitrary axisymmetric profiles is formulated by employing the displacement Green's functions, derived with the aid of Hankel integral transform technique. The problem is solved by assuming the contact pressure distribution in terms of a linear combination of admissible functions and undetermined coefficients. Those coefficients are then obtained by employing a collocation technique and an efficient numerical quadrature scheme. The accuracy of proposed solution technique is verified by comparing with existing solutions for rigid indentation on an elastic half-space. Selected numerical results for the indenters with flat-ended cylindrical and paraboloidal punch profiles are presented to portray the influence of surface energy effects on elastic fields of the finite layer. It is found that the presence of surface stresses renders the layer stiffer, and the size-dependent behavior of elastic fields is observed in the present solutions. In addition, the surface energy effects become more pronounced with smaller contact area; thus, the influence of surface energy cannot be ignored in the analysis of indentation problem especially when the indenter size is very small such as in the case of nanoindentation.
Hamada, Yoshitaka; Gotani, Hiroyuki; Hibino, Naohito; Tanaka, Yoshitaka; Satoh, Ryousuke; Sasaki, Kousuke; Kanchanathepsak, Thepparat
2016-01-01
Background The low-profile dorsal locking plating (DLP) technique is useful for treating dorsally comminuted intra-articular distal radius fractures; however, due to the complications associated with DLP, the technique is not widely used. Methods A retrospective review of 24 consecutive cases treated with DLP were done. Results All cases were classified into two types by surgical strategy according to the fracture pattern. In type 1, there is a volar fracture line distal to the watershed line in the dorsally displaced fragment, and this type is treated by H-framed DLP. In type 2, the displaced dorsal die-punch fragment is associated with a minimally displaced styloid shearing fracture or a transverse volar fracture line. We found that the die-punch fragment was reduced by the buttress effect of small l-shaped DLP after stabilization of the styloid shearing for the volar segment by cannulated screws from radial styloid processes. At 6 months after surgery, outcomes were good or excellent based on the modified Mayo wrist scores with no serious complications except one case. The mean range of motion of each type was as follows: the palmar flexion was 50, 65 degrees, dorsiflexion was 70, 75 degrees, supination was 85, 85 degrees, and pronation was 80, 80 degrees; in type 1 and 2, respectively. Conclusion DLP is a useful technique for the treatment of selected cases of dorsally displaced, comminuted intra-articular fractures of the distal radius with careful soft tissue coverage. PMID:28428920
Hayashi, Yoshikazu; Yamamoto, Hironori; Kita, Hiroto; Sunada, Keijiro; Sato, Hiroyuki; Yano, Tomonori; Iwamoto, Michiko; Sekine, Yutaka; Miyata, Tomohiko; Kuno, Akiko; Iwaki, Takaaki; Kawamura, Yoshiyuki; Ajibe, Hironari; Ido, Kenichi; Sugano, Kentaro
2005-01-01
AIM: To clarify clinical features of the NSAID-induced small bowel lesions using a new method of endoscopy. METHODS: This is a retrospective study and we analyzed seven patients with small bowel lesions while taking NSAIDs among 61 patients who had undergone double-balloon endoscopy because of gastro-intestinal bleeding or anemia between September 2000 and March 2004, at Jichi Medical School Hospital in Japan. Neither conventional EGD nor colonoscopy revealed any lesions of potential bleeding sources including ulcerations. Double-balloon endoscopy was carried out from oral approach in three patients, from anal approach in three patients, and from both approaches in one patient. RESULTS: Ulcers or erosions were observed in the ileum in six patients and in the jejunum in one patient, respectively. The ulcers were multiple in all the patients with different features from tiny punched out ulcers to deep ulcerations with oozing hemorrhage or scar. All the patients recovered uneventfully and had full resolution of symptoms after suspension of the drug. CONCLUSION: NSAIDs can induce injuries in the small bowel even in patients without any lesions in both the stomach and colon. PMID:16097059
Graham, M R; Myers, T; Evans, P; Davies, B; Cooper, S M; Bhattacharya, K; Grace, F M; Baker, J S
2011-01-01
Boxing exposes participants to the physiological response to high intensity exercise and also to direct body and brain trauma. Amateur boxing is increasing and females have also been included in the Olympics. The aim of this study is to assess the stress response and possible brain injury incurred during a match by measuring serum biomarkers associated with stress and cellular brain injury before and after combat. Sixteen male amateur boxers were studied retrospectively. The study population was divided into two groups: (a) a group that received predominantly punches to the head (PTH) and (b) a group that received predominantly punches to the body (PTB). Blood samples were taken before and five minutes after each contest. They were analysed for S-100B, neuron-specific enolase (NSE), creatine kinase (CK) and cortisol. The PTH group received direct contacts to the head (not blocked, parried or avoided) and to the body (n=8, age: 17.6 ± 5.3, years; height: 1.68 ± 0.13, meters; mass: 65.4 ± 20.3, kg). The PTB group received punches to the body including blocked and parried punches, but received no direct punches to the head, (n=8, mean ± SD, age: 19.1 ± 3.2 years; height: 1.70 ± 0.75, meters; mass: 68.5 ± 15 kg). Significant increases (P<0.05) were observed between pre- and post-combat serum concentrations in serum concentrations in PTH of S-100B (0.35 ± 0.61 vs. 0.54 ± 0.73, μg.L-1) NSE (19.7 ± 14 vs.31.1 ± 26.6, ng.ml-1) and cortisol (373 ± 202 vs. 756 ± 93, nmol.L-1). Significant increases (P<0.05) of creatine kinase were recorded in both groups. This study demonstrates significant elevations in neurochemical biomarkers in boxers who received direct blows to the head. However, further work is required to quantify this volumetric brain damage and long term clinical sequelae.
The healing effects of autologous platelet gel on acute human skin wounds.
Hom, David B; Linzie, Bradley M; Huang, Trevor C
2007-01-01
To compare the healing of full-thickness skin punch wounds treated with topical autologous platelet gel (APG) vs conventional therapy (antibiotic ointment and/or occlusive dressings) in healthy volunteers. A prospective, single-blind, pilot study comprising 80 full-thickness skin punch wounds (4 mm diameter) was conducted on the thighs of 8 healthy volunteers. With each subject serving as his or her own control (5 punch sites per leg), APG was applied topically on one thigh, and an antibiotic ointment and/or a semiocclusive dressing was applied on the other thigh. Healing was monitored for spontaneous wound closure by clinical assessment and by digital photographs over 6 months. Over 35 days, 64 serial dermal biopsy specimens (6 mm diameter) were analyzed (using hematoxylin-eosin, Mason trichrome, CD-34, and Ki-67 stains) to measure differences between treated and control sites for cellularity, granulation formation, vascularity, epithelialization, and cellular replication. Over a 42-day period, the APG-treated sites had statistically increased wound closure compared with controls by visual clinical assessment and by digital planimetry photographic measurements (P
Bartsch, Adam J; Benzel, Edward C; Miele, Vincent J; Morr, Douglas R; Prakash, Vikas
2012-05-01
In spite of ample literature pointing to rotational and combined impact dosage being key contributors to head and neck injury, boxing and mixed martial arts (MMA) padding is still designed to primarily reduce cranium linear acceleration. The objects of this study were to quantify preliminary linear and rotational head impact dosage for selected boxing and MMA padding in response to hook punches; compute theoretical skull, brain, and neck injury risk metrics; and statistically compare the protective effect of various glove and head padding conditions. An instrumented Hybrid III 50th percentile anthropomorphic test device (ATD) was struck in 54 pendulum impacts replicating hook punches at low (27-29 J) and high (54-58 J) energy. Five padding combinations were examined: unpadded (control), MMA glove-unpadded head, boxing glove-unpadded head, unpadded pendulum-boxing headgear, and boxing glove-boxing headgear. A total of 17 injury risk parameters were measured or calculated. All padding conditions reduced linear impact dosage. Other parameters significantly decreased, significantly increased, or were unaffected depending on padding condition. Of real-world conditions (MMA glove-bare head, boxing glove-bare head, and boxing glove-headgear), the boxing glove-headgear condition showed the most meaningful reduction in most of the parameters. In equivalent impacts, the MMA glove-bare head condition induced higher rotational dosage than the boxing glove-bare head condition. Finite element analysis indicated a risk of brain strain injury in spite of significant reduction of linear impact dosage. In the replicated hook punch impacts, all padding conditions reduced linear but not rotational impact dosage. Head and neck dosage theoretically accumulates fastest in MMA and boxing bouts without use of protective headgear. The boxing glove-headgear condition provided the best overall reduction in impact dosage. More work is needed to develop improved protective padding to minimize linear and rotational impact dosage and develop next-generation standards for head and neck injury risk.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghassemi-Armaki, Hassan; Leff, Asher C.; Taheri, Mitra L.
Compression-compression cyclic deformation of nanocrystalline NiTi tubes intended for medical stents and with an outer diameter of 1 mm and wall thickness of 70 μm was studied using micropillars produced by FIB with the loading axis orthogonal to the tube axis. These micropillars were cycled in a displacement-controlled mode using a nanoindenter equipped with a flat punch to strain levels of 4, 6 and 8% in each cycle and specimens were subjected to several hundred cycles. Furthermore, the cyclic response of two NiTi tubes, one with Af of 17 °C and the other with an Af of -5 °C ismore » compared. The texture of the tube with the Af of -5 °C was measured at the microscopic level using transmission electron microscopy and at the macroscopic level by X-ray diffraction and good agreement was noted. Characteristics such as i) a reduction in the forward transformation stress, ii) increase in maximum stress for a given displacement amplitude, and iii) a reduction in the hysteresis loop area, all with increasing number of cycles, observed typically during cyclic deformation of conventional macroscopic specimens, were captured in the micropillar cyclic tests. Our observations lead to the conclusion that micropillar compression testing in a cyclic mode can enable characterizing the orientation-dependent response in such small dimension components that see complex loading in service, and additionally provide an opportunity for calibrating constitutive equations in micromechanical models.« less
Liu, Xiaomin; Qu, Shuxin; Lu, Xiong; Ge, Xiang; Leng, Yang
2009-12-01
The aim of this study was to investigate the drug distribution in ultra-high molecular weight polyethylene (UHMWPE) loaded with alendronate sodium (ALN), which was developed to treat particle-induced osteolysis after artificial joint replacements, since the drug distribution in UHMWPE could play a key role in controlling drug release. A mixture of UHMWPE powder and ALN was dried and hot pressed to prepare UHMWPE loaded with ALN (UHMWPE-ALN). Fourier transform infrared spectroscopy analysis demonstrated that the hot press had no effect on the functional groups of ALN in UHMWPE-ALN. X-ray diffraction indicated that there was no phase change of the UHMWPE after hot pressing. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) spectra revealed the existence of characteristic elements and functional groups from ALN in UHMWPE-ALN, such as Na+, C3H8N+, PO3(-) and PO3H(-). In addition, SIMS images suggested that ALN did not agglomerate in UHMWPE-ALN. A small punch test and hardness test were carried out and the results indicated that ALN did not affect the mechanical properties at the present content level. The present study demonstrated that it was feasible to fabricate the un-agglomerated distributed drug in UHMWPE with good mechanical properties. This ALN loaded UHMWPE would have potential application in clinics.
Formability analysis of aluminum alloys through deep drawing process
NASA Astrophysics Data System (ADS)
Pranavi, U.; Janaki Ramulu, Perumalla; Chandramouli, Ch; Govardhan, Dasari; Prasad, PVS. Ram
2016-09-01
Deep drawing process is a significant metal forming process used in the sheet metal forming operations. From this process complex shapes can be manufactured with fewer defects. Deep drawing process has different effectible process parameters from which an optimum level of parameters should be identified so that an efficient final product with required mechanical properties will be obtained. The present work is to evaluate the formability of Aluminum alloy sheets using deep drawing process. In which effects of punch radius, lubricating conditions, die radius, and blank holding forces on deep drawing process observed for AA 6061 aluminum alloy sheet of 2 mm thickness. The numerical simulations are performed for deep drawing of square cups using three levels of aforesaid parameters like lubricating conditions and blank holding forces and two levels of punch radii and die radii. For numerical simulation a commercial FEM code is used in which Hollomon's power law and Hill's 1948 yield criterions are implemented. The deep drawing setup used in the FEM code is modeled using a CAD tool by considering the modeling requirements from the literature. Two different strain paths (150x150mm and 200x200mm) are simulated. Punch forces, thickness distributions and dome heights are evaluated for all the conditions. In addition failure initiation and propagation is also observed. From the results, by increasing the coefficient of friction and blank holding force, punch force, thickness distribution and dome height variations are observed. The comparison has done and the optimistic parameters were suggested from the results. From this work one can predict the formability for different strain paths without experimentation.
[Groupamatic 360 C1 and automated blood donor processing in a transfusion center].
Guimbretiere, J; Toscer, M; Harousseau, H
1978-03-01
Automation of donor management flow path is controlled by: --a 3 slip "port a punch" card, --the groupamatic unit with a result sorted out on punch paper tape, --the management computer off line connected to groupamatic. Data tracking at blood collection time is made by punching a card with the donor card used as a master card. Groupamatic performs: --a standard blood grouping with one run for registered donors and two runs for new donors, --a phenotyping with two runs, --a screening of irregular antibodies. Themanagement computer checks the correlation between the data of the two runs or the data of a single run and that of previous file. It updates the data resident in the central file and prints out: --the controls of the different blood group for the red cell panel, --The listing of error messages, --The listing of emergency call up, --The listing of collected blood units when arrived at the blood center, with quantitative and qualitative information such as: number of blood, units collected, donor addresses, etc., --Statistics, --Donor cards, --Diplomas.
Aircraft-Induced Hole Punch and Canal Clouds
NASA Astrophysics Data System (ADS)
Heymsfield, A. J.; Kennedy, P.; Massie, S. T.; Schmitt, C. G.; Wang, Z.; Haimov, S.; Rangno, A.
2009-12-01
The production of holes and channels in altocumulus clouds by two commercial turboprop aircraft is documented for the first time. An unprecedented data set combining in situ measurements from microphysical probes with remote sensing measurements from cloud radar and lidar, all operating from the NSF/NCAR C130 aircraft, as well as ground-based NOAA and CSU radars, is used to describe the radar/lidar properties of a hole punch cloud and channel and the ensuing ice microphysical properties and structure of the ice column that subsequently developed. Ice particle production by commercial turboprop aircraft climbing through clouds much warmer than the regions where contrails are produced has the potential to modify significantly the cloud microphysical properties and effectively seed them under some conditions. Jet aircraft may also be producing hole punch clouds when flying through altocumulus with supercooled droplets at heights lower than their normal cruise altitudes where contrails can form. Commercial aircraft therefore can generate ice and affect the clouds at temperatures as much as 30°C warmer than the -40°C contrail formation threshold temperature.
Nelsen, C E; Safir, G R; Hanson, A D
1978-01-01
Leaf water potential (Psi(leaf)) determinations were made on excised leaf samples using a commercial dew point hygrometer (Wescor Inc., Logan, Utah) and a thermocouple psychrometer operated in the isopiestic mode. With soybean leaves (Glycine max L.), there was good agreement between instruments; equilibration times were 2 to 3 hours. With cereals (Triticum aestivum L. and Hordeum vulgare L.), agreement between instruments was poor for moderately wilted leaves when 7-mm-diameter punches were used in the hygrometer and 20-mm slices were used in the psychrometer, because the Psi(leaf) values from the dew point hygrometer were too high. Agreement was improved by replacing the 7-mm punch samples in the hygrometer by 13-mm slices, which had a lower cut edge to volume ratio. Equilibration times for cereals were normally 6 to 8 hours. Spuriously high Psi(leaf) values obtained with 7-mm leaf punches may be associated with the ion release and reabsorption that occur upon tissue excision; such errors evidently depend both on the species and on tissue water status.
VMOMS — A computer code for finding moment solutions to the Grad-Shafranov equation
NASA Astrophysics Data System (ADS)
Lao, L. L.; Wieland, R. M.; Houlberg, W. A.; Hirshman, S. P.
1982-08-01
Title of program: VMOMS Catalogue number: ABSH Program obtainable from: CPC Program Library, Queen's University of Belfast, N. Ireland (See application form in this issue) Computer: PDP-10/KL10; Installation: ORNL Fusion Energy Division, Oak Ridge National Laboratory, Oak Ridge, TN 37830, USA Operating system: TOPS 10 Programming language used: FORTRAN High speed storage required: 9000 words No. of bits in a word: 36 Overlay structure: none Peripherals used: line printer, disk drive No. of cards in combined program and test deck: 2839 Card punching code: ASCII
A Summary of the Evaluation of PPG Herculite XP Glass in Punched Window and Storefront Assemblies
2013-01-01
frames for all IGU windows extruded from existing dies. The glazing was secured to the frame on all four sides with a 1/2-in bead width of DOW 995...lite and non-laminated IGU debris tests. A wood frame with a 4-in wide slit was placed behind the window to transform the debris cloud into a narrow...speed camera DIC Set-up laser deflection gauge shock tube window wood frame with slit high speed camerawell lit backdrop Debris Tracking Set-up laser
Digital pulse-shape analysis with a TRACE early silicon prototype
NASA Astrophysics Data System (ADS)
Mengoni, D.; Dueñas, J. A.; Assié, M.; Boiano, C.; John, P. R.; Aliaga, R. J.; Beaumel, D.; Capra, S.; Gadea, A.; Gonzáles, V.; Gottardo, A.; Grassi, L.; Herrero-Bosch, V.; Houdy, T.; Martel, I.; Parkar, V. V.; Perez-Vidal, R.; Pullia, A.; Sanchis, E.; Triossi, A.; Valiente Dobón, J. J.
2014-11-01
A highly segmented silicon-pad detector prototype has been tested to explore the performance of the digital pulse shape analysis in the discrimination of the particles reaching the silicon detector. For the first time a 200 μm thin silicon detector, grown using an ordinary floating zone technique, has been shown to exhibit a level discrimination thanks to the fine segmentation. Light-charged particles down to few MeV have been separated, including their punch-through. A coaxial HPGe detector in time coincidence has further confirmed the quality of the particle discrimination.
Improved Indentation Test for Measuring Nonlinear Elasticity
NASA Technical Reports Server (NTRS)
Eldridge, Jeffrey I.
2004-01-01
A cylindrical-punch indentation technique has been developed as a means of measuring the nonlinear elastic responses of materials -- more specifically, for measuring the moduli of elasticity of materials in cases in which these moduli vary with applied loads. This technique offers no advantage for characterizing materials that exhibit purely linear elastic responses (constant moduli of elasticity, independent of applied loads). However, the technique offers a significant advantage for characterizing such important materials as plasma-sprayed thermal-barrier coatings, which, in cyclic loading, exhibit nonlinear elasticity with hysteresis related to compaction and sliding within their microstructures.
1983-07-01
July 1983 Washington DC 20472 1s. NUMBER OP PAGES 287 14. MONITORING AGENCY NAME A AODRESSý./ dif.erent from Controlling Office) IS. SECURITY CLASS... controlling parameter used in the design of the upgrading scheme. However, the flat plate test indicated that more concern should be directed to punching shear...and type of structure. Very little duplication of experiments for control purposes has been performed. SUGGESTED RESEARCH After some thirty years of
EMHP: an accurate automated hole masking algorithm for single-particle cryo-EM image processing.
Berndsen, Zachary; Bowman, Charles; Jang, Haerin; Ward, Andrew B
2017-12-01
The Electron Microscopy Hole Punch (EMHP) is a streamlined suite of tools for quick assessment, sorting and hole masking of electron micrographs. With recent advances in single-particle electron cryo-microscopy (cryo-EM) data processing allowing for the rapid determination of protein structures using a smaller computational footprint, we saw the need for a fast and simple tool for data pre-processing that could run independent of existing high-performance computing (HPC) infrastructures. EMHP provides a data preprocessing platform in a small package that requires minimal python dependencies to function. https://www.bitbucket.org/chazbot/emhp Apache 2.0 License. bowman@scripps.edu. Supplementary data are available at Bioinformatics online. © The Author(s) 2017. Published by Oxford University Press.
Robotic hair harvesting system: a new proposal.
Lin, Xiang; Nakazawa, Toji; Yasuda, Ryuya; Kobayashi, Etsuko; Sakuma, Ichiro; Liao, Hongen
2011-01-01
Follicular Unit Extraction (FUE) has become a popular hair transplanting method for solving male-pattern baldness problem. Manually harvesting hairs one by one, however, is a tedious and time-consuming job to doctors. We design an accurate hair harvesting robot with a novel and efficient end-effector which consists of one digital microscope and a punch device. The microscope is first employed to automatically localize target hairs and then guides the punch device for harvesting after shifting. The end-effector shows average bias and precision of 0.014 mm by virtue of a rotary guidance design for the motorized shifting mechanism.
NASA Astrophysics Data System (ADS)
Volkov, Sergei S.; Vasiliev, Andrey S.; Aizikovich, Sergei M.; Sadyrin, Evgeniy V.
2018-05-01
Indentation of an elastic half-space with functionally graded coating by a rigid flat punch is studied. The half-plane is additionally subjected to distributed tangential stresses. Tangential stresses are represented in a form of Fourier series. The problem is reduced to the solution of two dual integral equations over even and odd functions describing distribution of unknown normal contact stresses. The solutions of these dual integral equations are constructed by the bilateral asymptotic method. Approximated analytical expressions for contact normal stresses are provided.
A simple code for use in shielding and radiation dosage analyses
NASA Technical Reports Server (NTRS)
Wan, C. C.
1972-01-01
A simple code for use in analyses of gamma radiation effects in laminated materials is described. Simple and good geometry is assumed so that all multiple collision and scattering events are excluded from consideration. The code is capable of handling laminates up to six layers. However, for laminates of more than six layers, the same code may be used to incorporate two additional layers at a time, making use of punch-tape outputs from previous computation on all preceding layers. Spectrum of attenuated radiation are obtained as both printed output and punch tape output as desired.
Exploration of PM2.5 filtration property of filter bag for environment protection
NASA Astrophysics Data System (ADS)
Zhu, Ruitian; Zheng, Jinwei; Ni, Bingxuan; Zhang, Peng
2017-06-01
In this paper, filter bag of polyphenylene sulfide (PPS) needle punched nonwoven for environment protection was investigated. The results showed that air permeability of sample was linear rise with the increase of the pressure drop. During the testing process, the residual pressure drop rose with the increase of cycles because of test dust attaching on the surface of the filter. The PM2.5 filtration efficiency was obtained of 99.854%, which was smaller than the dust filtration efficiency of 99.971% because of the fine particles taking larger proportion of the dust through the sample. Results show that this method of evaluating the PM2.5 filtration property is feasible.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cirilli, J.; DeRose, N.
1995-09-01
The site is a pharmaceutical facility located in Newark, New Jersey. The facility which has been in operation for approximately 90 years, previously contained a 15,000 gallon underground tank used to store TCE. Upon the tanks removal in the early 1980`s the tank integrity was found to have been compromised. In compliance with the NJDEP Industrial Site Recovery Act, the responsible party was required to locate DNAPL in the aquifer. Due to TCE`s relative density, vertical migration to depths greater than 80 feet has occurred. Lateral migration over distances greater than 500 feet has been documented. Currently, the investigation hasmore » focused on the neighboring cemetery, where approximately 20 deep soil borings have been advanced at selected locations downslope of the TCE source area. The soil borings were drilled by mud rotary methods to a depth that was determined in the field to be proximal to the bottom of the heterogeneous unconsolidated aquifer. Continuous split spoon soil sampling for detailed geologic interpretation and field screening utilizing an organic vapor instrument was performed. The Hydro Punch (HP II) sampler was used in the aqueous sampling model to collect a discrete ground water sample from the interface between the aquifer and the till.« less
Intratumoral histologic heterogeneity of gliomas. A quantitative study.
Paulus, W; Peiffer, J
1989-07-15
Quantitative data for intratumoral histologic heterogeneity were obtained by investigating ten small and ten large punched samples from 50 unembedded supratentorial gliomas. The 1000 samples were diagnosed according to the World Health Organization (WHO) classification and six histopathologic features associated with malignancy were evaluated (cellular density, nuclear pleomorphism, necroses, histologic architecture, vessels, and mitoses), each with defined gradations. The slides were read independently by two observers. The initially high interobserver variability (grade, 22.2%; type, 10.3%; and tumor presence/absence, 7.1%) was for the most part due to intermediate grades and types and was reduced to 1.7% after mutual review. Small samples showed lower mean grade than large samples and more often absence of tumor (7.6% versus 2.4%). Of all gliomas, 48% showed differently typed samples, 82% differently graded samples, and 62% benign and malignant grades. Intratumoral heterogeneity was higher for the necroses than for the other histopathologic features. Our results underscore the importance of extensive tissue sampling.
Yang, Hong; Zhou, Weixun; Lv, Hong; Wu, Dongsheng; Feng, Yunlu; Shu, Huijun; Jin, Meng; Hu, Lingling; Wang, Qiang; Wu, Dong; Chen, Jie; Qian, Jiaming
2017-05-01
Cytomegalovirus (CMV) infection has been shown to be related to severe or steroid-refractory ulcerative colitis (UC) flare-ups. The aim of this study was to evaluate the endoscopic and pathological characteristics of CMV colitis in patients with UC and to assess the predictive value of the endoscopic and pathological features of CMV colitis. A total of 50 consecutive UC patients with CMV infection who were admitted to Peking Union Medical College Hospital from 2010 to 2015 were enrolled in this study. Twenty-five UC patients with CMV infection (50.0%) had concurrent CMV colitis. When the cutoff value was set at 1150 copies, the sensitivity and specificity of blood CMV DNAq polymerase chain reaction for predicting CMV colitis were 44.4% and 78.9%, respectively. A higher proportion of endoscopic punched-out ulcers, irregular ulcers, and cobblestone-like appearance were observed among the patients in the CMV colitis group than those in the non-CMV colitis group (52.0% versus 20.0%, 60.0% versus 16.0%, and 20.0% versus 0%, respectively, P < 0.05). The number of CMV inclusion bodies per high-power field was significantly higher in those with punch-out ulcerations (25.7% versus 60.0%, P < 0.05). A higher grade of pathological inflammation was observed in the CMV colitis group than in the control group (68.0% versus 44.0%). Characteristic endoscopic features with punch-out ulcers and high CMV viremia load may be useful for predicting the presence of CMV colitis in histology. Punch-out ulcers were found to be associated with a higher number of inclusion bodies on histology, suggesting a role of targeted biopsy for endoscopist.
Moore, David J; Jain, Sonia; Dubé, Michael P; Daar, Eric S; Sun, Xiaoying; Young, Jason; Corado, Katya; Ellorin, Eric; Milam, Joel; Collins, Deborah; Blumenthal, Jill; Best, Brookie M; Anderson, Peter; Haubrich, Richard; Morris, Sheldon R
2018-05-02
Adherence is critical for efficacy of tenofovir disoproxil fumarate/emtricitabine (FTC) as preexposure prophylaxis (PrEP). Between February 2013 and February 2016, 398 men who have sex with men and transgender women were randomized 1:1 to receive individualized texting for adherence building (iTAB) or standard care (SoC) for 48 weeks. The primary endpoint was dried blood spot (DBS) tenofovir diphosphate (TFV-DP) concentrations at both week 12 and the last on-drug visit of >719 fmol/punch (ie, adequate adherence). Secondary outcomes included DBS TFV-DP concentrations of >1246 fmol/punch (ie, near-perfect adherence) and plasma FTC >350 ng/mL (consistent with dosing within the past 24 hours). Concentrations >719 fmol/punch of TFV-DP were found in 88.6% of participants at week 12 and 82.5% at week 48. For the primary endpoint, the study arms did not differ (72.0% in iTAB and 69.2% in SoC; P > .05). For the secondary composite endpoint of >1246 fmol/punch the iTAB arm was superior to SoC (33.5% vs 24.8%; P = .06), reaching statistical significance when adjusting for age (odds ratio, 1.56 [95% confidence interval, 1.00-2.42]; P < .05). At week 48, iTAB was superior to SoC for near-perfect adherence (51.0% vs 37.4%; P = .02). At week 12, iTAB was superior to SoC for dosing in past 24 hours by plasma FTC (47.5% vs 33.3%; P = .007), but not at weeks 24, 36, and 48 (all P > .05). Automated text messaging is a low-burden tool that improves durability of near-perfect PrEP adherence. NCT01761643.
Selectivity of a bromelain based enzymatic debridement agent: a porcine study.
Rosenberg, Lior; Krieger, Yuval; Silberstein, Eldad; Arnon, Ofer; Sinelnikov, Igor A; Bogdanov-Berezovsky, Alex; Singer, Adam J
2012-11-01
Debridement of the burn eschar is a cornerstone of burn wound care. Rapid enzymatic debridement with a bromelain-based agent (Debriding Gel Dressing-DGD) has recently been investigated. The current study was designed to further investigate the selectivity of DGD to burned eschar in a larger number and more varied types of wounds. A systematic animal experiment was conducted to determine the effects of DGD on normal, non-injured skin, burns, exposed dermis of donor sites, and skin punch biopsy wells. Partial thickness dermal burns and partial thickness skin graft donor sites were created on a pig and treated with a 4-h application of DGD or its control hydrating vehicle that does not have any activity except hydration. Punch biopsy samples were taken before and after treatment and microscopically assessed for evidence of tissue viability and its respective components thickness. Rapid dissolution of the burn eschar was noted in all DGD but not vehicle treated burns. There was no apparent damage to the underlying sub eschar dermis, donor sites, normal skin or punch biopsy wells after exposure to DGD. While the thickness of the treated tissues slightly increased due to edema, the increase in dermal thickness was similar after treatment with DGD or its vehicle. The increase in the cross section surface area of the treated punch biopsy wells was similar after treatment with DGD and its control vehicle. Exposure of the burn eschar to DGD results in its rapid dissolution. Exposure of normal skin or non-burned dermis to DGD has no effects demonstrating its selectivity to eschar. Copyright © 2012 Elsevier Ltd and ISBI. All rights reserved.
Zhang, Xiaowei; Sahraei, Elham; Wang, Kai
2016-01-01
Separator integrity is an important factor in preventing internal short circuit in lithium-ion batteries. Local penetration tests (nail or conical punch) often produce presumably sporadic results, where in exactly similar cell and test set-ups one cell goes to thermal runaway while the other shows minimal reactions. We conducted an experimental study of the separators under mechanical loading, and discovered two distinct deformation and failure mechanisms, which could explain the difference in short circuit characteristics of otherwise similar tests. Additionally, by investigation of failure modes, we provided a hypothesis about the process of formation of local “soft short circuits” in cells with undetectable failure. Finally, we proposed a criterion for predicting onset of soft short from experimental data. PMID:27581185
Design of Tools for Press-countersinking or Dimpling 0.040-inch-thick-24S-T Sheet
NASA Technical Reports Server (NTRS)
Templin, R L; Fogwell, J W
1942-01-01
A set of dimpling tools was designed for 0.040-inch 24S-T sheet and flush-type rivets 1/8 inch in diameter with 100 degree countersunk heads. The dimples produced under different conditions of pressure, sheet thickness, and drill diameter are presented as cross-sectional photographs magnified 20 times. The most satisfactory values for the dimpling tools were found to be: maximum punch diameter, 0.231 inch; maximum die diameter, 0.223 inch; maximum mandrel diameter, 0.128 inch; dimple angle, 100 degree; punch springback angle, 1 1/2 degree; and die springback angle, 2 degree.
Precision hole punching on composite fiber reinforced polymer panels
NASA Astrophysics Data System (ADS)
Abdullah, A. B.; Zain, M. S. M.; Chan, H. Y.; Samad, Z.
2017-12-01
Structural materials, such as composite panels, can only be assembled, and in most cases through the use of fasteners, which are fitted into the drilled holes. However, drilling is costly and time consuming, thus affecting productivity. This research aims to develop an alternative method to drilling. In this paper, the precision of the holes was measured and the effects of the die clearance to the areas around the holes were evaluated. Measurement and evaluation were performed based on the profile of the holes constructed using Alicona IFM, a 3D surface measurement technique. Results showed that punching is a potential alternative to drilling but still requires improvements.
Külling, Fabrice Alexander; Ebneter, Lukas; Rempfler, Georg Stefan; Zdravkovic, Vilijam
2018-05-01
To prove that a modified closing mechanism of the rongeur gives better precision compared to the old Kerrison rongeur. Forty persons from the departments of orthopaedic surgery, urology and neurosurgery (35 orthopaedic, 2 urology and 3 neurosurgery) took part in the study. All participants were asked to punch ten times in a first step with either the old Kerrison rongeur with the scissors-like handle or the modified punch with a new parallel closing mechanism. In a second step, they punched 10 times with the other instrument. Shaft movement in three dimensions was measured with a stereoscopic, contactless, full-field digital image correlation system. The new rongeur is significantly more precise with less movement in all three dimensions. The mechanical model of the new rongeur shows that the momentum needed to keep the tip at the initial position changes only minimally during the closing act on the new model. The new rongeur is more precise compared to the old Kerrison model. It is more robust against changes in the direction of the finger forces and may reduce soreness, fatigue and CTS in spine surgeons. Not applicable: technical study.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nelsen, C.E.; Safir, G.R.; Hanson, A.D.
1978-01-01
Leaf water potential (Psi/sub leaf/) determinations were made on excised leaf samples using a commercial dew point hygrometer (Wescor Inc., Logan, Utah) and a thermocouple psychrometer operated in the isopiestic mode. With soybean leaves (Glycine max L.), there was good agreement between instruments; equilibration times were 2 to 3 hours. With cereals (Triticum aestivum L. and Hordeum vulgare L.), agreement between instruments was poor for moderately wilted leaves when 7-mm-diameter punches were used in the hygrometer and 20-mm slices were used in the psychrometer, because the Psi/sub leaf/ values from the dew point hygrometer were too high. Agreement was improvedmore » by replacing the 7-mm punch samples in the hygrometer by 13-mm slices, which had a lower cut edge to volume ratio. Equilibration times for cereals were normally 6 to 8 hours. Spuriously high Psi/sub leaf/ values obtained with 7-mm leaf punches may be associated with the ion release and reabsorption that occur upon tissue excision; such errors evidently depend both on the species and on tissue water status.« less
Energy Absorption of Expansion Tube Considering Local Buckling Characteristics
NASA Astrophysics Data System (ADS)
Ahn, Kwang-Hyun; Kim, Jin-Sung; Huh, Hoon
This paper deals with the crash energy absorption and the local buckling characteristics of the expansion tube during the tube expanding processes. In order to improve energy absorption capacity of expansion tubes, local buckling characteristics of an expansion tube must be considered. The local buckling load and the absorbed energy during the expanding process were calculated for various types of tubes and punch shapes with finite element analysis. The energy absorption capacity of the expansion tube is influenced by the tube and the punch shape. The material properties of tubes are also important parameter for energy absorption. During the expanding process, local buckling occurs in some cases, which causes significant decreasing the absorbed energy of the expansion tube. Therefore, it is important to predict the local buckling load accurately to improve the energy absorption capacity of the expansion tube. Local buckling takes place relatively easily at the large punch angle and expansion ratio. Local buckling load is also influenced by both the tube radius and the thickness. In prediction of the local buckling load, modified Plantema equation was used for strain hardening and strain rate hardening. The modified Plantema equation shows a good agreement with the numerical result.
Optimal design of a main driving mechanism for servo punch press based on performance atlases
NASA Astrophysics Data System (ADS)
Zhou, Yanhua; Xie, Fugui; Liu, Xinjun
2013-09-01
The servomotor drive turret punch press is attracting more attentions and being developed more intensively due to the advantages of high speed, high accuracy, high flexibility, high productivity, low noise, cleaning and energy saving. To effectively improve the performance and lower the cost, it is necessary to develop new mechanisms and establish corresponding optimal design method with uniform performance indices. A new patented main driving mechanism and a new optimal design method are proposed. In the optimal design, the performance indices, i.e., the local motion/force transmission indices ITI, OTI, good transmission workspace good transmission workspace(GTW) and the global transmission indices GTIs are defined. The non-dimensional normalization method is used to get all feasible solutions in dimensional synthesis. Thereafter, the performance atlases, which can present all possible design solutions, are depicted. As a result, the feasible solution of the mechanism with good motion/force transmission performance is obtained. And the solution can be flexibly adjusted by designer according to the practical design requirements. The proposed mechanism is original, and the presented design method provides a feasible solution to the optimal design of the main driving mechanism for servo punch press.
Gabaude, C M; Guillot, M; Gautier, J C; Saudemon, P; Chulia, D
1999-07-01
Compressibility properties of pharmaceutical materials are widely characterized by measuring the volume reduction of a powder column under pressure. Experimental data are commonly analyzed using the Heckel model from which powder deformation mechanisms are determined using mean yield pressure (Py). Several studies from the literature have shown the effects of operating conditions on the determination of Py and have pointed out the limitations of this model. The Heckel model requires true density and compacted mass values to determine Py from force-displacement data. It is likely that experimental errors will be introduced when measuring the true density and compacted mass. This study investigates the effects of true density and compacted mass on Py. Materials having different particle deformation mechanisms are studied. Punch displacement and applied pressure are measured for each material at two compression speeds. For each material, three different true density and compacted mass values are utilized to evaluate their effect on Py. The calculated variation of Py reaches 20%. This study demonstrates that the errors in measuring true density and compacted mass have a greater effect on Py than the errors incurred from not correcting the displacement measurements due to punch elasticity.
Quantitation of Tenofovir and Emtricitabine in Dried Blood Spots (DBS) with LC-MS/MS
Zheng, Jia-Hua; Guida, Louis A; Rower, Caitlin; Castillo-Mancilla, Jose; Meditz, Amie; Klein, Brandon; Kerr, Becky Jo; Langness, Jacob; Bushman, Lane; Kiser, Jennifer; Anderson, Peter L.
2013-01-01
A reversed-phase high performance liquid chromatographic (LC), tandem mass spectrometry (MS/MS) assay for the determination of tenofovir (TFV) and emtricitabine (FTC) in dried blood spots (DBS) from human whole blood was developed and validated. Whole blood samples were spotted, dried, and a 3mm punch was extracted with methanol for analysis by LC-MS/MS utilizing stable isotope labeled internal standards. The assay was validated over the range of 2.5ng/mL to 1,000ng/mL for TFV and 2.5ng/mL to 5,000ng/mL for FTC. The method was accurate (within ± 15% of control) and precise (coefficient of variation ≤ 15%) for hematocrit concentrations ranging from 25% to 76%; using edge punches versus center punches; and spot volumes of 10µL to 50µL. Analytes were stable for five freeze/thaw cycles and up to 6 days at room temperature, whereas long-term storage required −20°C or −80°C. Comparison of TFV and FTC in DBS versus plasma yielded r2 ≥ 0.96, indicating that DBS can be used as a plasma alternative for pharmacokinetic analyses in vivo. PMID:24055850
A Human Model of Small Fiber Neuropathy to Study Wound Healing
Illigens, Ben M. W.; Gibbons, Christopher H.
2013-01-01
The aim of this study was to develop a human model of acute wound healing that isolated the effects of small fiber neuropathy on the healing process. Twenty-five healthy subjects had the transient receptor vanilloid 1 agonist capsaicin and placebo creams topically applied to contralateral areas on the skin of the thigh for 48 hours. Subjects had shallow (1.2 millimeter) and deep (>3 millimeter) punch skin biopsies from each thigh on days 1 and 14. Biopsy wound healing was monitored photographically until closure. Intra-epidermal and sweat-gland nerve fiber densities were measured for each biopsy. Shallow wounds in capsaicin-treated sites healed more slowly than in placebo treated skin with biopsies taken on day 1 (P<0.001) and day 14 (P<0.001). Deep biopsies in the capsaicin and placebo areas healed at similar rates at both time points. Nerve fiber densities were reduced only in capsaicin treated regions (P<0.01). In conclusion, topical application of capsaicin causes a small fiber neuropathy and is associated with a delay in healing of shallow, but not deep wounds. This novel human model may prove valuable in the study of wound healing in patients with neuropathy. PMID:23382960
A human model of small fiber neuropathy to study wound healing.
Illigens, Ben M W; Gibbons, Christopher H
2013-01-01
The aim of this study was to develop a human model of acute wound healing that isolated the effects of small fiber neuropathy on the healing process. Twenty-five healthy subjects had the transient receptor vanilloid 1 agonist capsaicin and placebo creams topically applied to contralateral areas on the skin of the thigh for 48 hours. Subjects had shallow (1.2 millimeter) and deep (>3 millimeter) punch skin biopsies from each thigh on days 1 and 14. Biopsy wound healing was monitored photographically until closure. Intra-epidermal and sweat-gland nerve fiber densities were measured for each biopsy. Shallow wounds in capsaicin-treated sites healed more slowly than in placebo treated skin with biopsies taken on day 1 (P<0.001) and day 14 (P<0.001). Deep biopsies in the capsaicin and placebo areas healed at similar rates at both time points. Nerve fiber densities were reduced only in capsaicin treated regions (P<0.01). In conclusion, topical application of capsaicin causes a small fiber neuropathy and is associated with a delay in healing of shallow, but not deep wounds. This novel human model may prove valuable in the study of wound healing in patients with neuropathy.
Familial atrophia maculosa varioliformis cutis: an ultrastructural study.
Dall'Oglio, F; Nasca, M R; Taparelli, F; Bacchelli, B; Micali, G
2001-01-01
Atrophia maculosa varioliformis cutis is a rare and distinctive form of idiopathic facial macular noninflammatory atrophy that may rarely be observed in members of the same family. We describe two brothers, ages 14 and 16 years, with spontaneously appearing, asymptomatic, varioliform and linear atrophic lesions. Their past medical history was positive for varicella occurring in childhood without residual facial scarring. Routine laboratory investigations and screening for circulating autoantibodies were negative. Both patients were concordant for HLA A2 and DQ4.1. Routine and ultrastructural histologic examination of a punch biopsy specimen showed the presence of scarce, small, fragmented elastic fibers and compact collagen bundles associated with hypertrophic fibroblasts in the dermis. Our patients remained clinically stable, untreated, over a 2-year follow-up period. No long-term follow-up data have previously been reported.
Experimental formability analysis of bondal sandwich sheet
NASA Astrophysics Data System (ADS)
Kami, Abdolvahed; Banabic, Dorel
2018-05-01
Metal/polymer/metal sandwich sheets have recently attracted the interests of industries like automotive industry. These sandwich sheets have superior properties over single-layer metallic sheets including good sound and vibration damping and light weight. However, the formability of these sandwich sheets should be enhanced which requires more research. In this paper, the formability of Bondal sheet (DC06/viscoelastic polymer/DC06 sandwich sheet) was studied through different types of experiments. The mechanical properties of Bondal were determined by uniaxial tensile tests. Hemispherical punch stretching and hydraulic bulge tests were carried out to determine the forming limit diagram (FLD) of Bondal. Furthermore, cylindrical and square cup drawing tests were performed in dry and oil lubricated conditions. These tests were conducted at different blank holding forces (BHFs). An interesting observation about Bondal sheet deep drawing was obtaining of higher drawing depths at dry condition in comparison with oil-lubricated condition.
Ghassemi-Armaki, Hassan; Leff, Asher C.; Taheri, Mitra L.; ...
2017-06-22
Compression-compression cyclic deformation of nanocrystalline NiTi tubes intended for medical stents and with an outer diameter of 1 mm and wall thickness of 70 μm was studied using micropillars produced by FIB with the loading axis orthogonal to the tube axis. These micropillars were cycled in a displacement-controlled mode using a nanoindenter equipped with a flat punch to strain levels of 4, 6 and 8% in each cycle and specimens were subjected to several hundred cycles. Furthermore, the cyclic response of two NiTi tubes, one with Af of 17 °C and the other with an Af of -5 °C ismore » compared. The texture of the tube with the Af of -5 °C was measured at the microscopic level using transmission electron microscopy and at the macroscopic level by X-ray diffraction and good agreement was noted. Characteristics such as i) a reduction in the forward transformation stress, ii) increase in maximum stress for a given displacement amplitude, and iii) a reduction in the hysteresis loop area, all with increasing number of cycles, observed typically during cyclic deformation of conventional macroscopic specimens, were captured in the micropillar cyclic tests. Our observations lead to the conclusion that micropillar compression testing in a cyclic mode can enable characterizing the orientation-dependent response in such small dimension components that see complex loading in service, and additionally provide an opportunity for calibrating constitutive equations in micromechanical models.« less
Effects of Testing Method on Stretch-Flangeability of Dual-Phase 980/1180 Steel Grades
NASA Astrophysics Data System (ADS)
Madrid, Mykal; Van Tyne, Chester J.; Sadagopan, Sriram; Pavlina, Erik J.; Hu, Jun; Clarke, Kester D.
2018-04-01
Challenging fuel economy and safety standards in the automotive industry have led to the need for materials with higher strength while maintaining levels of formability that meet component manufacturing requirements. Advanced high-strength steels, such as dual-phase steels with tensile strengths of 980 MPa and 1180 MPa, are of interest to address this need. Increasing the strength of these materials typically comes at the expense of ductility, which may result in problems when stamping parts with trimmed or sheared edges, as cracking at the sheared edge may occur at lower strains. Here, hole expansion tests were performed with different punch geometries (conical and flat-bottom) and different edge conditions (sheared and machined) to understand the effects of testing conditions on performance, and these results are discussed in terms of mechanical properties and microstructures.
Effects of Testing Method on Stretch-Flangeability of Dual-Phase 980/1180 Steel Grades
NASA Astrophysics Data System (ADS)
Madrid, Mykal; Van Tyne, Chester J.; Sadagopan, Sriram; Pavlina, Erik J.; Hu, Jun; Clarke, Kester D.
2018-06-01
Challenging fuel economy and safety standards in the automotive industry have led to the need for materials with higher strength while maintaining levels of formability that meet component manufacturing requirements. Advanced high-strength steels, such as dual-phase steels with tensile strengths of 980 MPa and 1180 MPa, are of interest to address this need. Increasing the strength of these materials typically comes at the expense of ductility, which may result in problems when stamping parts with trimmed or sheared edges, as cracking at the sheared edge may occur at lower strains. Here, hole expansion tests were performed with different punch geometries (conical and flat-bottom) and different edge conditions (sheared and machined) to understand the effects of testing conditions on performance, and these results are discussed in terms of mechanical properties and microstructures.
NASA Technical Reports Server (NTRS)
Bogomolov, E. A.; Yevstafev, Y. Y.; Karakadko, V. K.; Lubyanaya, N. D.; Romanov, V. A.; Totubalina, M. G.; Yamshchikov, M. A.
1975-01-01
A system for the recording and processing of telescope data is considered for measurements of EW asymmetry. The information is recorded by 45 channels on a continuously moving 35-mm film. The dead time of the recorder is about 0.1 sec. A sorting electronic circuit is used to reduce the errors when the statistical time distribution of the pulses is recorded. The recorded information is read out by means of photoresistors. The phototransmitter signals are fed either to the mechanical recorder unit for preliminary processing, or to a logical circuit which controls the operation of the punching device. The punched tape is processed by an electronic computer.
Using Force to Punch Holes: Mechanics of Contractile Nanomachines.
Brackmann, Maximilian; Nazarov, Sergey; Wang, Jing; Basler, Marek
2017-09-01
Using physical force to translocate macromolecules across a membrane has the advantage of being a universal solution independent of the properties of the target membrane. However, physically punching a stiff membrane is not a trivial task and three things are necessary for success: a sharp tip, a source of energy, and the ability to strongly bind to the target. In this review we describe the basic mechanism of membrane puncturing by contractile nanomachines with a focus on the T4 phage, R-type pyocin, and the bacterial Type VI secretion system (T6SS) based on recent studies of the structures and dynamics of their assembly. Copyright © 2017 Elsevier Ltd. All rights reserved.
A comparison of the palatability of flavored oral contrasts.
Arya, Rajiv; Hansen, Allison; Taira, Breena R; Packy, Theodore; Singer, Adam J
2009-09-01
The aim of this study was to compare the taste of computed tomography (CT) oral contrast diluted with various flavored drinks. We performed a prospective, blinded, controlled trial in healthy adult volunteers. Subjects were assigned to ingest four 250-mL aliquots of oral contrast media diluted in water, Crystal Light Lemonade (Kraft Food, Northfield, Ill), Tropical Punch Kool-Aid (Kraft Food), and Tropicana orange juice (Pepsi Bottling Company, Sommers, NY) in random order; and the taste of the solution was measured with a 100-mm visual analogue scale and 5-point Likert scale from very worst to best. Between-group comparison of the taste scores was performed with repeated-measures analysis of variance and pairwise t tests. The study had 80% power to detect an effect size 0.75 SDs. There were 23 subjects; mean (SD) age was 33 (7.7) and 30% were female. The mean (SD) taste scores were water 12 (5), lemonade 37 (21), Kool-Aid 44 (20), and orange juice 40 (20) (P < .05). The proportion of subjects completely ingesting the contrast in water (65%) was significantly less than that with other 3 study solutions (100% each, P < .001). Dilution of oral contrast media with lemonade, fruit punch, or orange juice is tastier than with water. The choice of the specific juice used to dilute the oral contrast should be individualized based on patient preferences and availability.
PhyloChip™ microarray comparison of sampling methods used for coral microbial ecology
Kellogg, Christina A.; Piceno, Yvette M.; Tom, Lauren M.; DeSantis, Todd Z.; Zawada, David G.; Andersen, Gary L.
2012-01-01
Interest in coral microbial ecology has been increasing steadily over the last decade, yet standardized methods of sample collection still have not been defined. Two methods were compared for their ability to sample coral-associated microbial communities: tissue punches and foam swabs, the latter being less invasive and preferred by reef managers. Four colonies of star coral, Montastraea annularis, were sampled in the Dry Tortugas National Park (two healthy and two with white plague disease). The PhyloChip™ G3 microarray was used to assess microbial community structure of amplified 16S rRNA gene sequences. Samples clustered based on methodology rather than coral colony. Punch samples from healthy and diseased corals were distinct. All swab samples clustered closely together with the seawater control and did not group according to the health state of the corals. Although more microbial taxa were detected by the swab method, there is a much larger overlap between the water control and swab samples than punch samples, suggesting some of the additional diversity is due to contamination from water absorbed by the swab. While swabs are useful for noninvasive studies of the coral surface mucus layer, these results show that they are not optimal for studies of coral disease.
Effect of YAG laser cutting on stretch-flangeability of TRIP steels
NASA Astrophysics Data System (ADS)
Nagasaka, A.; Sugimoto, K.-I.; Kobayashi, M.
2003-10-01
The effect of YAG laser cutting on the stretch-flangeability of transformation-induced plasticity (TRIP)-aided dual-phase sheet steels (TDP steels), which had different contents of C, Si and Mn, was examined. In TDP steels in which Si and Mn contents were constant and C content was varied ((O.1 0.4)C 1.5Si 1.5Mn, mass%), the strength stretch-flangeability balance (TS × λ) of holes obtained by either laser cutting, hole-punching or drilling decreased with increasing C content. When the C content was 0.3 mass% or higher, the λ value in the case of laser cutting, which originally was as good as that in the case of drilling, decreased to a level comparable to that in the case of hole-punching. On the other hand, in TDP steels in which Si and Mn contents were varied and C content was kept constant (0.2C (1.0 2.0)Si (1.0 2.0)Mn, mass%), the λ value of the hole obtained by hote-punching was low under high TS, however, the value was greatly improved by laser cutting. Based on the above results, we demonstrated that YAG laser cutting contributes to the improvement of the stretch-flangeability of 980-MPa-class TDP steels with 0.2 mass% C.
PhyloChip™ microarray comparison of sampling methods used for coral microbial ecology.
Kellogg, Christina A; Piceno, Yvette M; Tom, Lauren M; DeSantis, Todd Z; Zawada, David G; Andersen, Gary L
2012-01-01
Interest in coral microbial ecology has been increasing steadily over the last decade, yet standardized methods of sample collection still have not been defined. Two methods were compared for their ability to sample coral-associated microbial communities: tissue punches and foam swabs, the latter being less invasive and preferred by reef managers. Four colonies of star coral, Montastraea annularis, were sampled in the Dry Tortugas National Park (two healthy and two with white plague disease). The PhyloChip™ G3 microarray was used to assess microbial community structure of amplified 16S rRNA gene sequences. Samples clustered based on methodology rather than coral colony. Punch samples from healthy and diseased corals were distinct. All swab samples clustered closely together with the seawater control and did not group according to the health state of the corals. Although more microbial taxa were detected by the swab method, there is a much larger overlap between the water control and swab samples than punch samples, suggesting some of the additional diversity is due to contamination from water absorbed by the swab. While swabs are useful for noninvasive studies of the coral surface mucus layer, these results show that they are not optimal for studies of coral disease. Published by Elsevier B.V.
Effect of blend ratio of PP/kapok blend nonwoven fabrics on oil sorption capacity.
Lee, Young-Hee; Kim, Ji-Soo; Kim, Do-Hyung; Shin, Min-Seung; Jung, Young-Jin; Lee, Dong-Jin; Kim, Han-Do
2013-01-01
More research and development on novel oil sorbent materials is needed to protect the environmental pollution. New nonwoven fabrics (pads) of polypropylene (PP)/kapok blends (blend ratio: 100/0, 75/25, 50/50, 25/75 and 10/90) were prepared by needle punching process at a fixed (optimized) condition (punch density: 50 punches/cm2 and depth: 4mm). This study focused on the effect of blend ratio of PP/kapok nonwoven fabrics on oil sorption capacities to find the best blend ratio having the highest synergy effect. The PP/kapok blend (50/50) sample has the lowest bulk density and showed the best oil absorption capacity. The oil sorption capacity of PP/kapok blend (50/50) nonwoven fabric for kerosene/soybean oil [21.09/27.01 (g oil/g sorbent)] was 1.5-2 times higher than those of commercial PP pad oil sorbents. The highest synergy effect of PP/kapok blend (50/50) was ascribed to the lowest bulk density of PP/kapok blend (50/50), which might be due to the highest morphologically incompatibility between PP fibre and kapok. These results suggest that the PP/kapok blend (50/50) having the highest synergy effect has a high potential as a new high-performance oil sorbent material.
Hoagland, Brenda; Moreira, Ronaldo I; De Boni, Raquel B; Kallas, Esper G; Madruga, José Valdez; Vasconcelos, Ricardo; Goulart, Silvia; Torres, Thiago S; Marins, Luana M S; Anderson, Peter L; Luz, Paula M; Costa Leite, Iuri da; Liu, Albert Y; Veloso, Valdilea G; Grinsztejn, Beatriz
2017-04-06
The efficacy of pre-exposure prophylaxis (PrEP) in preventing sexual acquisition of human immunodeficiency virus (HIV) is well established. Little is known about the feasibility of PrEP implementation in middle-income settings with concentrated epidemics among men who have sex with men (MSM) and transgender women (TGW). PrEP Brasil is a prospective, multicentre, open-label demonstration project assessing PrEP delivery in the context of the Brazilian Public Health System. HIV-uninfected MSM and TGW in 3 referral centres in Rio de Janeiro and São Paulo were evaluated for eligibility and offered 48 weeks of daily emtricitabine/tenofovir for PrEP. Concentrations of tenofovir diphosphate in dried blood spot samples (DBS) at week 4 after enrolment (early adherence) were measured. Predictors of drug levels were assessed using ordinal logistic regression models considering the DBS drug level as a 3 level variable (<350 fmol/punch, ≥350-699 fmol/punch and ≥700 fmol/punch). 1,270 individuals were assessed for participation; n = 738 were potentially eligible and n = 450 were offered PrEP (PrEP uptake was 60.9%). Eligible but not enrolled individuals were younger, had lower HIV risk perception and had lower PrEP awareness. At week 4, 424 participants (of the 450 enrolled) had DBS TFV-DP concentrations, 94.1% in the protective range (≥350 fmol/punch, consistent with ≥2 pills per week), and 78% were in the highly protective range (≥700 fmol/punch, ≥4 pills per week). Participants with ≥12 years of schooling had 1.9 times the odds (95%CI 1.10-3.29) of a higher versus lower drug level than participants with <12 years of schooling. Condomless receptive anal intercourse in the prior 3 months was also associated with higher drug levels (adjusted OR = 1.78; 95% CI 1.08-2.94). The high uptake and early adherence indicate that PrEP for high-risk MSM and TGW can be successfully delivered in the context of the Brazilian Public Health System. Interventions to address disparities on PrEP awareness and HIV risk perception among the younger and less educated are urgently needed in order to maximize the impact of this prevention strategy on the reduction of HIV infection among MSM and TGW in Brazil.
Identifying Major Transitions in the Evolution of Lithic Cutting Edge Production Rates
Clarkson, Chris
2016-01-01
The notion that the evolution of core reduction strategies involved increasing efficiency in cutting edge production is prevalent in narratives of hominin technological evolution. Yet a number of studies comparing two different knapping technologies have found no significant differences in edge production. Using digital analysis methods we present an investigation of raw material efficiency in eight core technologies broadly representative of the long-term evolution of lithic technology. These are bipolar, multiplatform, discoidal, biface, Levallois, prismatic blade, punch blade and pressure blade production. Raw material efficiency is assessed by the ratio of cutting edge length to original core mass. We also examine which flake attributes contribute to maximising raw material efficiency, as well as compare the difference between expert and intermediate knappers in terms of cutting edge produced per gram of core. We identify a gradual increase in raw material efficiency over the broad sweep of lithic technological evolution. The results indicate that the most significant transition in efficiency likely took place with the introduction of small foliate biface, Levallois and prismatic blade knapping, all introduced in the Middle Stone Age / Middle Palaeolithic among early Homo sapiens and Neanderthals. This suggests that no difference in raw material efficiency existed between these species. With prismatic blade technology securely dated to the Middle Palaeolithic, by including the more recent punch and pressure blade technology our results dispel the notion that the transition to the Upper Palaeolithic was accompanied by an increase in efficiency. However, further increases in cutting edge efficiency are evident, with pressure blades possessing the highest efficiency in this study, indicating that late/epi-Palaeolithic and Neolithic blade technologies further increased efficiency. PMID:27936135
Identifying Major Transitions in the Evolution of Lithic Cutting Edge Production Rates.
Muller, Antoine; Clarkson, Chris
2016-01-01
The notion that the evolution of core reduction strategies involved increasing efficiency in cutting edge production is prevalent in narratives of hominin technological evolution. Yet a number of studies comparing two different knapping technologies have found no significant differences in edge production. Using digital analysis methods we present an investigation of raw material efficiency in eight core technologies broadly representative of the long-term evolution of lithic technology. These are bipolar, multiplatform, discoidal, biface, Levallois, prismatic blade, punch blade and pressure blade production. Raw material efficiency is assessed by the ratio of cutting edge length to original core mass. We also examine which flake attributes contribute to maximising raw material efficiency, as well as compare the difference between expert and intermediate knappers in terms of cutting edge produced per gram of core. We identify a gradual increase in raw material efficiency over the broad sweep of lithic technological evolution. The results indicate that the most significant transition in efficiency likely took place with the introduction of small foliate biface, Levallois and prismatic blade knapping, all introduced in the Middle Stone Age / Middle Palaeolithic among early Homo sapiens and Neanderthals. This suggests that no difference in raw material efficiency existed between these species. With prismatic blade technology securely dated to the Middle Palaeolithic, by including the more recent punch and pressure blade technology our results dispel the notion that the transition to the Upper Palaeolithic was accompanied by an increase in efficiency. However, further increases in cutting edge efficiency are evident, with pressure blades possessing the highest efficiency in this study, indicating that late/epi-Palaeolithic and Neolithic blade technologies further increased efficiency.
Characterization of Friction Stir Welded Tubes by Means of Tube Bulge Test
NASA Astrophysics Data System (ADS)
D'Urso, G.; Longo, M.; Giardini, C.
2011-05-01
Mechanical properties of friction stir welded joints are generally evaluated by means of conventional tensile test. This testing method might provide insufficient information because maximum strain obtained in tensile test before necking is small; moreover, the application of tensile test is limited when the joint path is not linear or even when the welds are executed on curved surfaces. Therefore, in some cases, it would be preferable to obtain the joints properties from other testing methods. Tube bulge test can be a valid solution for testing circumferential or longitudinal welds executed on tubular workpieces. The present work investigates the mechanical properties and the formability of friction stir welded tubes by means of tube bulge tests. The experimental campaign was performed on tubular specimens having a thickness of 3 mm and an external diameter of 40 mm, obtained starting from two semi-tubes longitudinally friction stir welded. The first step, regarding the fabrication of tubes, was performed combining a conventional forming process and friction stir welding. Sheets in Al-Mg-Si-Cu alloy AA6060 T6 were adopted for this purpose. Plates having a dimension of 225×60 mm were bent (with a bending axis parallel to the main dimension) in order to obtain semi-tubes. A particular care was devoted to the fabrication of forming devices (punch and die) in order to minimize the springback effects. Semi-tubes were then friction stir welded by means of a CNC machine tool. Some preliminary tests were carried out by varying the welding parameters, namely feed rate and rotational speed. A very simple tool having flat shoulder and cylindrical pin was used. The second step of the research was based on testing the welded tubes by means of tube bulge test. A specific equipment having axial actuators with a conical shape was adopted for this study. Some analyses were carried out on the tubes bulged up to a certain pressure level. In particular, the burst pressure and the wall thickness were measured for each tested tube.
Saussereau, E; Lacroix, C; Gaulier, J M; Goulle, J P
2012-02-15
A novel approach has been developed for the illicit drugs quantitative determination using dried blood spots (DBS) on filter paper. The illicit drugs tested were opiates (morphine and its 3- and 6-glucuronide metabolites, codeine, 6-monoacetylmorphine), cocainics (ecgonine methylester, benzoylecgonine, cocaine, cocaethylene) and amphetamines (amphetamine, methamphetamine, MDA, MDMA, MDEA). The described method, requiring a small blood volume, is based on high performance liquid chromatography coupled to tandem mass spectrometry using on-line extraction. A Whatman card 903 was spotted with 30μL of whole blood and left overnight to dry at room temperature. A 3-mm diameter disk was removed using a manual punch, suspended in 150μL of water for 10min with ultrasonication, and then 100μL was injected in the on-line LC-MS/MS system. An Oasis HLB was used as an extraction column and a C18 Atlantis as an analytical column. The chromatographic cycle was performed with 20mM ammonium formate buffer (pH 2.8) (solvent A) and acetonitrile/solvent A (90:10, v/v) gradient in 16min. Detection was performed in positive electrospray ionization mode (ESI+) with a Quattro Micro (Waters). Recoveries of all analytes were up to 80%. DBS were stored in duplicate at 4°C and -20°C for up to 6 months. Illicit drugs seemed to be much more stabled at -20°C. Furthermore, it was tested whether analysis of DBS may be as reliable as that of whole blood investigating authentic samples; significant correlations were obtained. This DBS assay has potential as rapid, sensitive and inexpensive option for the illicit drugs determination in small blood volumes, which seems of great interest in suspected cases of driving under the influence of drugs. Copyright © 2011 Elsevier B.V. All rights reserved.
Formability of Annealed Ni-Ti Shape Memory Alloy Sheet
NASA Astrophysics Data System (ADS)
Fann, K. J.; Su, J. Y.; Chang, C. H.
2018-03-01
Ni-Ti shape memory alloy has two specific properties, superelasiticity and shape memory effect, and thus is widely applied in diverse industries. To extend its application, this study attempts to investigate the strength and cold formability of its sheet blank, which is annealed at various temperatures, by hardness test and by Erichsen-like cupping test. As a result, the higher the annealing temperature, the lower the hardness, the lower the maximum punch load as the sheet blank fractured, and the lower the Erichsen-like index or the lower the formability. In general, the Ni-Ti sheet after annealing has an Erichsen-like index between 8 mm and 9 mm. This study has also confirmed via DSC that the Ni-Ti shape memory alloy possesses the austenitic phase and shows the superelasticity at room temperature.
[Perinatal mortality in foreign workers (author's transl)].
Höfling, H J; Jonas, R; Brusis, E; Lochmüller, H; Selbmann, H K; Holzmann, K; Zander, J
1975-03-01
From 1970 to 1972, there were 216 perinatal deaths among 5595 newborns at the I. Frauenklinik der Universität München. 54 of these deaths were children of foreign workers (so-called "Gastarbeiter"). The data have been processed on punch cards and analysed by a computer. The differences noted underwent significance testing by the CHI-Quadrat test. Only statistical significant results are published. The perinatal mortality in the above period shows no difference between foreign and German ward patients. There is, however, a significant lower perinatal mortality in private patients. We feel that this difference is due to a significant lower rate of prematures in the private patient group. The cocial status as well as higher interest and motivation in health resulting in better prenatal care are discussed as causal reasons for this fact.
Johanson, Helene C; Hyland, Valentine; Wicking, Carol; Sturm, Richard A
2009-04-01
We describe here a method for DNA elution from buccal cells and whole blood both collected onto Whatman FTA technology, using methanol fixation followed by an elution PCR program. Extracted DNA is comparable in quality to published Whatman FTA protocols, as judged by PCR-based genotyping. Elution of DNA from the dried sample is a known rate-limiting step in the published Whatman FTA protocol; this method enables the use of each 3-mm punch of sample for several PCR reactions instead of the standard, one PCR reaction per sample punch. This optimized protocol therefore extends the usefulness and cost effectiveness of each buccal swab sample collected, when used for nucleic acid PCR and genotyping.
NASA Technical Reports Server (NTRS)
Rowlette, John J. (Inventor)
1987-01-01
A liquid-impermeable plate (10) having through-plate conductivity with essentially zero resistance comprises an insulator sheet (12) having a series of spaced perforations (14) each of which contains a metal element (16) sealingly received into the perforation (14). A low-cost plate can readily be manufactured by punching a thermoplastic sheet (40) such as polypropylene with a punching tool (52), filling the apertures with led spheres (63) having a diameter smaller than the holes (50) but larger than the thickness of the sheet, sweeping excess spheres (62) off the sheet with a doctor blade (60) and then pressing a heated platen (74) onto the sheet to swage the spheres into a cylindrical shape and melt the surrounding resin to form a liquid-impermeable collar (4) sealing the metal into the sheet.
NASA Technical Reports Server (NTRS)
Rowlette, John J. (Inventor)
1985-01-01
A liquid-impermeable plate (10) having throughplate conductivity with essentially zero resistance comprises an insulator sheet (12) having a series of spaced perforations (14) each of which contains a metal element (16) sealingly received into the perforation (14). A low-cost plate can readily be manufactured by punching a thermoplastic sheet (40) such as polypropylene with a punching tool (52), filling the apertures with lead spheres (63) having a diameter smaller than the holes (50) but larger than the thickness of the sheet, sweeping excess spheres (62) off the sheet with a doctor blade (60) and then pressing a heated platen (74) onto the sheet to swage the spheres into a cylindrical shape and melt the surrounding resin to form a liquid-impermeable collar (4) sealing the metal into the sheet.
Impact of various factors on radioactivity distribution in different DBS papers.
Ren, Xiao; Paehler, Tobias; Zimmer, Manfred; Guo, Zuyu; Zane, Patricia; Emmons, Gary T
2010-08-01
Dried blood spot (DBS) sampling could potentially become the preferred blood collection technique in toxicological and clinical studies. Autoradiography was performed to study compound distribution within a dbs under different conditions using five papers, 31ETF, Grade 226, 903(®), FTA(®) and FTA(®) Elute. The results showed an uneven distribution in all papers with common distribution patterns regardless of compounds: decreased concentrations along the edge, the volcano effect in the middle and the speckle pattern in the center. Treated papers were more readily influenced by environmental factors. Autoradiography enables visualization of a compound's distribution and can guide bioanalytical assay development by allowing convenient evaluation of factors, such as choice of paper, spotting volume, punch size, punch location, temperature and humidity.
Wire electric-discharge machining and other fabrication techniques
NASA Technical Reports Server (NTRS)
Morgan, W. H.
1983-01-01
Wire electric discharge machining and extrude honing were used to fabricate a two dimensional wing for cryogenic wind tunnel testing. Electric-discharge cutting is done with a moving wire electrode. The cut track is controlled by means of a punched-tape program and the cutting feed is regulated according to the progress of the work. Electric-discharge machining involves no contact with the work piece, and no mechanical force is exerted. Extrude hone is a process for honing finish-machined surfaces by the extrusion of an abrasive material (silly putty), which is forced through a restrictive fixture. The fabrication steps are described and production times are given.
Allen, J. R. L.
1997-01-01
Mammalian tracks and trackways are widely preserved at all stratigraphical levels in the Flandrian sediments of tidal mudflat and marsh origins which formed over the last 8000–9000 years on the marginal wetlands of the inner Bristol Channel and Severn Estuary. The fauna recorded in this way, however, is less diverse than that known from the few, small assemblages of skeletal remains, including some from archaeological sites, so far assessed. Missing or rarely represented in terms of tracks are the smaller of the large mammals. Humans are represented by tracks throughout the Flandrian deposits. In the earlier Flandrian, they were accompanied by deer and aurochs which gave way, in the later Flandrian, to domesticated cattle and sheep/goat; there are sporadic indications of the presence of horse. Wolf/dog, represented by just two records, is the only smaller large mammal so far recorded as a track. The tracks were made, modified, and eventually preserved under a wide variety of sedimentological conditions on the margins of the estuary. Those environmental conditions constrained the quality of the anatomical evidence preserved in the tracks but can be inferred from the character of the tracks. Field experiments suggest that the moisture content of the sediment at the time was crucial to the general nature of the tracks. The mudflat–marsh silts which received the tracks varied from semi-liquid to firm, depending on tidal and seasonal factors and on the elevation of the sedimentary surface relative to the tidal frame. Some tracks were made in marsh peats which offered little resistance. Deep tracks preserving little detail were produced in weak sediments of high moisture content; tracks formed in strong, firm muds retained full anatomical detail. Referring to mechanical theory, and to a series of laboratory experiments using plasticine, the act of making a track is shown to be similar in character and effect to the indentation of an ideal elastic–plastic material by a punch. The punch represents the descending limb of the animal, the face of the punch the sole of the animal's foot, and the elastic–plastic material the sediment which is pierced and deformed by the downward action of the limb. The character of the experimental tracks, and the range and relative size of the deformation structures they include, is qualitatively similar to what is recorded from the field. Many of the tracks recorded from the field were variously modified in a changeable and dynamic environment before final burial and preservation.
15 CFR 700.31 - Metalworking machines.
Code of Federal Regulations, 2011 CFR
2011-01-01
... machines covered by this section include: Bending and forming machines Boring machines Broaching machines... Planers and shapers Polishing, lapping, boring, and finishing machines Punching and shearing machines...
15 CFR 700.31 - Metalworking machines.
Code of Federal Regulations, 2012 CFR
2012-01-01
... machines covered by this section include: Bending and forming machines Boring machines Broaching machines... Planers and shapers Polishing, lapping, boring, and finishing machines Punching and shearing machines...
15 CFR 700.31 - Metalworking machines.
Code of Federal Regulations, 2013 CFR
2013-01-01
... machines covered by this section include: Bending and forming machines Boring machines Broaching machines... Planers and shapers Polishing, lapping, boring, and finishing machines Punching and shearing machines...
15 CFR 700.31 - Metalworking machines.
Code of Federal Regulations, 2014 CFR
2014-01-01
... machines covered by this section include: Bending and forming machines Boring machines Broaching machines... Planers and shapers Polishing, lapping, boring, and finishing machines Punching and shearing machines...
15 CFR 700.31 - Metalworking machines.
Code of Federal Regulations, 2010 CFR
2010-01-01
... machines covered by this section include: Bending and forming machines Boring machines Broaching machines... Planers and shapers Polishing, lapping, boring, and finishing machines Punching and shearing machines...
Code of Federal Regulations, 2014 CFR
2014-01-01
... constitute integral links in developing the history of, or facts regarding, financial transactions or... listings punched cards, computer-produced listings, microfilm, and magnetic storage media (i.e., magnetic...
Code of Federal Regulations, 2013 CFR
2013-01-01
... constitute integral links in developing the history of, or facts regarding, financial transactions or... listings punched cards, computer-produced listings, microfilm, and magnetic storage media (i.e., magnetic...
Code of Federal Regulations, 2012 CFR
2012-01-01
... constitute integral links in developing the history of, or facts regarding, financial transactions or... listings punched cards, computer-produced listings, microfilm, and magnetic storage media (i.e., magnetic...
Code of Federal Regulations, 2011 CFR
2011-01-01
... constitute integral links in developing the history of, or facts regarding, financial transactions or... listings punched cards, computer-produced listings, microfilm, and magnetic storage media (i.e., magnetic...
Ultrasonic real-time in-die monitoring of the tablet compaction process-a proof of concept study.
Stephens, James D; Kowalczyk, Brian R; Hancock, Bruno C; Kaul, Goldi; Cetinkaya, Cetin
2013-02-14
The mechanical properties of a drug tablet can affect its performance (e.g., dissolution profile and its physical robustness. An ultrasonic system for real-time in-die tablet mechanical property monitoring during compaction has been demonstrated. The reported set-up is a proof of concept compaction monitoring system which includes an ultrasonic transducer mounted inside the upper punch of the compaction apparatus. This upper punch is utilized to acquire ultrasonic pressure wave phase velocity waveforms and extract the time-of-flight of pressure waves travelling within the compact at a number of compaction force levels during compaction. The reflection coefficients for the waves reflecting from punch tip-powder bed interface are extracted from the acquired waveforms. The reflection coefficient decreases with an increase in compaction force, indicating solidification. The data acquisition methods give an average apparent Young's moduli in the range of 8-20 GPa extracted during the compaction and release/decompression phases in real-time. A monitoring system employing such methods is capable of determining material properties and the integrity of the tablet during compaction. As compared to the millisecond time-scale dwell time of a typical commercial compaction press, the micro-second pulse duration and ToF of an acoustic pulse are sufficiently fast for real-time monitoring. Copyright © 2012 Elsevier B.V. All rights reserved.
Jain, Raka; Quraishi, Rizwana; Verma, Arpita
2017-01-01
Assessment of cotinine, a metabolite of nicotine in body fluids, is an important approach for validating the self-report among tobacco users. Adaptation of assays on dried urine spots (DUSs) has advantages of ease of collection, transportation, minimal invasiveness, and requirement of small volume. The aim of the present study was to develop an efficient method for testing cotinine in DUSs and evaluating its clinical applicability. This involved optimization of conditions for detection, recovery, and stability of cotinine from dried urine, spotted on filter paper. Enzyme-linked immunosorbent assay was used for screening, whereas confirmation was done by gas chromatography. For clinical applicability, urine samples of tobacco users were tested. Water was found to be a suitable extracting solvent as compared to carbonate-bicarbonate buffer (pH 9.2) and saline. Screening was achieved by two punches taken from a 20 μl (diameter 1.3 cm) spotted urine samples, and confirmation was achieved by five complete circles each of 20 μl sample volume. The recovery was found to be 97% in water. Limit of detection for the method was found to be 100 ng/ml. No signs of significant degradation were found under all storage conditions. All the urine samples of tobacco users were found to be positive by a conventional method as well as DUSs, and the method proved to be efficient. DUS samples are a useful alternative for biological monitoring of recent nicotine use, especially in developing countries where sample logistics could be an important concern.
Mechanical properties of gray and white matter brain tissue by indentation
Budday, Silvia; Nay, Richard; de Rooij, Rijk; Steinmann, Paul; Wyrobek, Thomas; Ovaert, Timothy C.; Kuhl, Ellen
2015-01-01
The mammalian brain is composed of an outer layer of gray matter, consisting of cell bodies, dendrites, and unmyelinated axons, and an inner core of white matter, consisting primarily of myelinated axons. Recent evidence suggests that microstructural differences between gray and white matter play an important role during neurodevelopment. While brain tissue as a whole is rheologically well characterized, the individual features of gray and white matter remain poorly understood. Here we quantify the mechanical properties of gray and white matter using a robust, reliable, and repeatable method, flat-punch indentation. To systematically characterize gray and white matter moduli for varying indenter diameters, loading rates, holding times, post-mortem times, and locations we performed a series of n=192 indentation tests. We found that indenting thick, intact coronal slices eliminates the common challenges associated with small specimens: it naturally minimizes boundary effects, dehydration, swelling, and structural degradation. When kept intact and hydrated, brain slices maintained their mechanical characteristics with standard deviations as low as 5% throughout the entire testing period of five days post mortem. White matter, with an average modulus of 1.895kPa±0.592kPa, was on average 39% stiffer than gray matter, p<0.01, with an average modulus of 1.389kPa±0.289kPa, and displayed larger regional variations. It was also more viscous than gray matter and responded less rapidly to mechanical loading. Understanding the rheological differences between gray and white matter may have direct implications on diagnosing and understanding the mechanical environment in neurodevelopment and neurological disorders. PMID:25819199
Analysis of benzodiazepines and their metabolites using DBS cards and LC-MS/MS.
Lee, Heesang; Park, Yujin; Jo, Jiyeong; In, Sangwhan; Park, Yonghoon; Kim, Eunmi; Pyo, Jaesung; Choe, Sanggil
2015-10-01
Dried Blood Spot (DBS) has been used a blood extraction method for inherited metabolic disorder screening since 1960s. With introduction of LC-MS/MS, not only DBS could be used to analysis drugs in small blood volume, but in various fields, such as toxicology, drug therapeutic monitoring, drug diagnostic screening, and illicit drugs. In toxicology field, many drugs (e.g. benzodiazepines, acetaminophen, small molecule drugs) have been tested with DBS. Compared with earlier blood extraction methods (SPE and LLE), DBS has lots of advantages; lower blood volume (less than 50μL), shorter analysis time caused by a more concise analysis procedure and lower cost. We optimized the DBS procedure and LC-MS/MS conditions for 18 benzodiazepines, seven benzodiazepine metabolites, and one z-drug (zolpidem) analysis in blood. 30μL of whole blood was spotted on FTA DMPK card C and dried for 2h in a desiccator. A 6-mm disk was punched and vortexed for 1min in a centrifuge tube with 300μL methanol/acetonitrile mixture (1:1, v/v). After evaporation, redissolved in 100μL mobile phase of LC-MS/MS and 5μL was injected. In the analysis for 26 target compounds in blood, all of the method validation parameters - LLOD, LLOQ, accuracy (intra- and inter-assay), and precision (intra- and inter-assay) - were satisfied with method validation criteria, within 15%. The results of matrix effect, recovery, and process efficiency were good. We developed a fast and reliable sample preparation method using DBS for 26 benzodiazepines, benzodiazepine metabolites, and z-drug (zolpidem). Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
21 CFR 888.4540 - Orthopedic manual surgical instrument.
Code of Federal Regulations, 2012 CFR
2012-04-01
..., femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench. (b) Classification...
21 CFR 888.4540 - Orthopedic manual surgical instrument.
Code of Federal Regulations, 2010 CFR
2010-04-01
..., femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench. (b) Classification...
21 CFR 888.4540 - Orthopedic manual surgical instrument.
Code of Federal Regulations, 2013 CFR
2013-04-01
..., femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench. (b) Classification...
21 CFR 888.4540 - Orthopedic manual surgical instrument.
Code of Federal Regulations, 2011 CFR
2011-04-01
..., femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench. (b) Classification...
21 CFR 888.4540 - Orthopedic manual surgical instrument.
Code of Federal Regulations, 2014 CFR
2014-04-01
..., femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench. (b) Classification...
Data-management and information system
NASA Technical Reports Server (NTRS)
Long, J. J.; Hatfield, J. N.; Diethelm, M. R.; Masters, G.
1977-01-01
User command language consists of unabbreviated English words. System allows user to create, delete, sort, merge, update, punch, or transfer all or portion of any file in system without programmer assistance.
MODIFICATIONS OF THE RAND REAC,
The major items of the modification program were the installation of a removable plugboard of the type used on the International Business Machines punched card tabulators, and a digital readout device.
... punch drink Skim milk Fewer calories, less sugar, plus calcium 980 calories 725 calories 255 fewer calories ... with low-fat dip or dressing 100% fruit juice box or bottle of water optional dessert (choose ...
Kwon, Byung Su; Suh, Dong Soo; Lee, Nam Kyung; Song, Yong Jung; Choi, Kyung Un; Kim, Ki Hyung
2017-03-07
Perivascular epithelioid cell tumor (PEComa) is a rare subtype of mesenchymal origin tumor composed of epithelioid cells which exhibits immunohistochemical co-expressions of melanocytic markers and smooth muscle markers. In the first case, malignant uterine PEComa with vaginal and multiple lung metastasis was misdiagnosed preoperatively as uterine leiomyosarcoma despite a preoperative punch biopsy and immunohistochemical analysis of the metastatic vaginal mass. In the second case, synchronous uterine PEComa showing benign histology with lymph node involvement was incidentally detected after a staging operation for ovarian cancer. Definitive diagnosis of uterine PEComa was achieved only after hysterectomy despite preoperative assessment with pelvic magnetic resonance imaging and punch biopsy of metastatic lesion. The authors report two rare cases of uterine PEComa diagnosed postoperatively based on the morphologic and immunohistochemical features.
Stress intensity factors in a cracked infinite elastic wedge loaded by a rigid punch
NASA Technical Reports Server (NTRS)
Erdogan, F.; Civelek, M. B.
1978-01-01
A plane elastic wedge-shaped solid was split through the application of a rigid punch. It was assumed that the coefficient of friction on the the contact area was constant, and the problem had a plane of symmetry with respect to loading and geometry, with the crack in the plane of symmetry. The problem was formulated in terms of a system of integral equations with the contact stress and the derivative of the crack surface displacement as the unknown functions. The solution was obtained for an internal crack and for an edge crack. The results include primarily the stress intensity factors at the crack tips, and the measure of the stress singularity at the wedge apex, and at the end points of the contact area.
Poswal, Arvind; Bhutia, Sangay; Mehta, Ruby
2011-01-01
Follicular unit extraction (FUE) is an accepted method of extracting individual follicular unit grafts for hair transplant surgery. Since follicles are harvested from the back of the scalp using tiny punches resulting in minimal scarring, it has gained rapid acceptance among the patients. However, due care needs to be exercised while performing FUE. FUE should not be confused with the older plug graft extraction methods of coring out hair-bearing skin plugs. Lack of due diligence while performing such extractions can lead to subluxation of the grafts into the subdermal layer of scalp. Overtumescence of the scalp donor area, use of blunt punches and trying to “core” out the full thickness grafts can all contribute to this. The following cases illustrate some pitfalls to be avoided while performing FUE and the adverse consequences if they occur. PMID:22121268
... Search Skin Experts Skin Treatments Hair Transplants Share » HAIR TRANSPLANTS Before (left) and after (right) - front of ... transplant. Photo courtesy of N. Sadick What are hair transplants? In punch transplanting, a plug containing hair ...
High transmission Ni compound refractive lens for high energy X-rays
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brancewicz, M., E-mail: brancew@spring8.or.jp; Itou, M.; Sakurai, Y.
We present a new planar Ni compound refractive lens for high energy X-rays (116 keV). The lens is composed of identical plano-concave elements with longitudinal parabolic grooves manufactured by a punch technique. In order to increase the lens transmission, the thickness of the single lens at the parabolic groove vertex was reduced to less than 5 μm and the radius of curvature was reduced to about 20 μm. The small radius of curvature allowed us to reduce the number of single elements needed to get the focal length of 3 m to 54 single lenses. The gain parameter has beenmore » significantly improved compared to the previous lenses due to higher transmission, but the focused beam size and its gain are not as good as expected, mostly due to the aberrations caused by the lens shape imperfections.« less
A computer program for creating keyword indexes to textual data files
Moody, David W.
1972-01-01
A keyword-in-context (KWIC) or out-of-context (KWOC) index is a convenient means of organizing information. This keyword index program can be used to create either KWIC or KWOC indexes of bibliographic references or other types of information punched on. cards, typed on optical scanner sheets, or retrieved from various Department of Interior data bases using the Generalized Information Processing System (GIPSY). The index consists of a 'bibliographic' section and a keyword-section based on the permutation of. document titles, project titles, environmental impact statement titles, maps, etc. or lists of descriptors. The program can also create a back-of-the-book index to documents from a list of descriptors. By providing the user with a wide range of input and output options, the program provides the researcher, manager, or librarian with a means of-maintaining a list and index to documents in. a small library, reprint collection, or office file.
Objectifying when to halt a boxing match: a video analysis of fatalities.
Miele, Vincent J; Bailes, Julian E
2007-02-01
Although numerous prestigious medical organizations have called for its abolishment, participation in the sport of boxing has reached an all-time high among both men and women, and its elimination is unlikely in the near future. Physicians should strive to increase boxing safety by improving the rules of competition, which have evolved minimally over the past two centuries. Currently, subjective criteria are used to determine whether or not a contest should be halted. Developing a standardized, objective method of determining when a contest should be halted would be a significant paradigm shift and could increase the safety of the sport's participants. This study analyzed the number and types of punches landed in a typical professional match, in bouts considered to be competitive and in those that ended in fatalities, to determine whether or not this would be a practical method of differentiating between these groups. Three groups of professional boxing matches were defined at the beginning of the study: 1) a "fatal" group, consisting of bouts that resulted in the death of a participant; 2) a "classic" group that represented competitive matches; and 3) a "control" group of 4000 professional boxing matches representing the average bout. A computer program known as Punchstat (Compubox, Inc., Manorville, NY) was used in the objective analysis of these matches via videotape playback. Several statistically significant differences were discovered between matches that resulted in fatalities and the control group. These include the number of punches landed per round, the number of power punches landed per round, and the number of power punches thrown per round by losing boxers. However, when the fatal bouts were compared with the most competitive bouts, these differences were no longer evident. Based on the data analyzed between the control and fatal-bout groups, a computerized method of counting landed blows at ringside could provide sufficient data to stop matches that might result in fatalities. However, such a process would become less effective as matches become more competitive, and implementing such a change would significantly decrease the competitive nature of the sport. Therefore, other methods of quantifying acceleration-deceleration brain injuries are necessary to improve the safety of boxing.
NASA Astrophysics Data System (ADS)
Awang Soh, Ahmad Afiq Sabqi; Mat Jafri, Mohd Zubir; Azraai, Nur Zaidi
2017-07-01
In Malay world, there is a spirit traditional ritual where they use it as healing practices or for normal life. Malay martial arts (silat) also is not exceptional where some branch of silat have spirit traditional ritual where they said can help them in combat. In this paper, we will not use any ritual, instead we will use some medicinal and environment change when they are performing. There will be 2 performers (fighter) selected, one of them have an experience in martial arts training and another performer does not have experience. Motion Capture (MOCAP) camera will help observe and analyze this move. 8 cameras have been placed in the MOCAP room 2 on each side of the wall facing toward the center of the room from every angle. This will help prevent the loss detection of a marker that been stamped on the limb of a performer. Passive marker has been used where it will reflect the infrared to the camera sensor. Infrared is generated by the source around the camera lens. A 60 kg punching bag was hung on the iron bar function as the target for the performer when throws a punch. Markers also have been stamped on the punching bag so we can detect the movement how far can it swing when hit by the performer. 2 performers will perform 2 moves each with the same position and posture. For every 2 moves, we have made the environment change without the performer notice about it. The first 2 punch with normal environment, second part we have played a positive music to change the performer's mood and third part we have put a medicine (cream/oil) on the skin of the performer. This medicine will make the skin feel a little bit hot. This process repeated to another performer with no experience. The position of this marker analyzed by the Cortex Motion Analysis software where from this data, we can estimate the kinetics and kinematics of the performer. It shows that the increase of kinetics for every part because of the change in the environment, and different result for the 2 performers.
78 FR 20352 - Endangered and Threatened Species Permit Applications
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-04
... Applicant: Burns and McDonnell Engineering, Kansas City, Missouri. Applicant requests an amendment to a..., identify, and release using mist nets and harp traps; collect tissue samples using wing punches, hair...
ERIC Educational Resources Information Center
Teaching PreK-8, 1995
1995-01-01
Describes five new and creative products for classroom use to help celebrate Earth Day (April 22): a craft book, curriculum activity guide, workshop series, punch out kit, and interactive book. Product descriptions include price and ordering information. (TM)
NASA Technical Reports Server (NTRS)
Liang, Steven Y.; Dornfeld, David A.; Nickerson, Jackson A.
1987-01-01
The coloring effect on the acoustic emission signal due to the frequency response of the data acquisition/processing instrumentation may bias the interpretation of AE signal characteristics. In this paper, a frequency domain deconvolution technique, which involves the identification of the instrumentation transfer functions and multiplication of the AE signal spectrum by the inverse of these system functions, has been carried out. In this way, the change in AE signal characteristics can be better interpreted as the result of the change in only the states of the process. Punch stretching process was used as an example to demonstrate the application of the technique. Results showed that, through the deconvolution, the frequency characteristics of AE signals generated during the stretching became more distinctive and can be more effectively used as tools for process monitoring.
NASA Astrophysics Data System (ADS)
Sharma, Ankush; Patnaik, Amar
2018-03-01
The present investigation evaluates the effects of waste marble dust, collected from the marble industries of Rajasthan, India, on the mechanical properties of needle-punched nonwoven jute fiber/epoxy composites. The composites with varying filler contents from 0 wt.% to 30 wt.% marble dust were prepared using vacuum-assisted resin-transfer molding. The influences of the filler material on the void content, tensile strength, flexural strength, interlaminar shear strength (ILSS), and thermal conductivity of the hybrid composites have been analyzed experimentally under the desired optimal conditions. The addition of marble dust up to 30 wt.% increases the flexural strength, ILSS, and thermal conductivity, but decreases the tensile strength. Subsequently, the fractured surfaces of the particulate-filled jute/epoxy composites were analyzed microstructurally by field-emission scanning electron microscopy.
A new recreational mechanism for the boxer's knuckle: cause for concern?
Javed, M; Hemington-Gorse, S; Shokrollahi, K
2011-07-01
Traumatic injuries of the metacarpophalangeal joints are a common occurrence in professional and recreational sports such as boxing and martial arts, especially the fourth and fifth metacarpals. Injury usually results from a forceful impact with a clenched fist. The spectrum of injuries varies from simple skin laceration to extensor mechanism disruption, dorsal capsule rupture, metacarpal fractures and carpometacarpal joint injuries. These injuries are well documented in boxers as well as in patients who had been involved in fights and assaults. We report on two patients sustaining similar injuries to the dorsum of the hand but following punching of a recreational 'punching machine'. We describe the patterns of injury encountered and summarise the treatment. For clinical and safety reasons as well as the potential medicolegal implications, we believe it is important to highlight this mechanism of injury.
A new recreational mechanism for the boxer’s knuckle: cause for concern?
Hemington-Gorse, S; Shokrollahi, K
2011-01-01
Traumatic injuries of the metacarpophalangeal joints are a common occurrence in professional and recreational sports such as boxing and martial arts, especially the fourth and fifth metacarpals. Injury usually results from a forceful impact with a clenched fist. The spectrum of injuries varies from simple skin laceration to extensor mechanism disruption, dorsal capsule rupture, metacarpal fractures and carpometacarpal joint injuries. These injuries are well documented in boxers as well as in patients who had been involved in fights and assaults. We report on two patients sustaining similar injuries to the dorsum of the hand but following punching of a recreational ’punching machine’. We describe the patterns of injury encountered and summarise the treatment. For clinical and safety reasons as well as the potential medicolegal implications, we believe it is important to highlight this mechanism of injury. PMID:21943451
What boxing-related stimuli reveal about response behaviour.
Ottoboni, Giovanni; Russo, Gabriele; Tessari, Alessia
2015-01-01
When two athletes meet inside the ropes of the boxing ring to fight, their cognitive systems have to respond as quickly as possible to a manifold of stimuli to assure victory. In the present work, we studied the pre-attentive mechanisms, which form the basis of an athlete's ability in reacting to an opponent's punches. Expert boxers, beginner boxers and people with no experience of boxing performed a Simon-like task where they judged the colour of the boxing gloves worn by athletes in attack postures by pressing two lateralised keys. Although participants were not instructed to pay attention to the direction of the punches, beginner boxers' responses resembled a defence-related pattern, expert boxers' resembled counterattacks, whereas non-athletes' responses were not influenced by the unrelated task information. Results are discussed in the light of an expertise-related action simulation account.
The principle of a three-staged operation in the surgery of acne scars.
Whang, K K; Lee, M
1999-01-01
Acne scars cannot be effectively corrected by a single treatment modality because of their widely varied depth and width. We assessed the effectiveness of staged combinations of several surgical modalities in the treatment of acne scars. Focal chemical peeling, carbon dioxide (CO2) laser, scar excision, punch grafting, and dermabrasion were used. Initially, focal chemical peeling was performed on all patients and then CO2 laser, scar excision, and punch grafts were used for deep scars. Finally, dermabrasion was done for the remaining scars. Seventy-five percent of patients showed excellent or good results. The degree of improvement increased as the follow-up periods and number of focal chemical peeling procedures increased and as the 3-staged operation progressed. A 3-staged operation is effective in the treatment of patients with various types of acne scars.
Bermejo-Fenoll, Ambrosio; López-Jornet, María Pía; Jiménez-Torres, María José; Camacho-Alonso, Fabio; Orduña-Domingo, Albina
2007-07-01
The authors designed a pressure forceps, called the "B forceps," for use in performing biopsies. They compared biopsy specimens taken with and without the aid of the B forceps from buccal mucosa of 84 patients divided equally into two groups, all of whom satisfied the World Health Organization's diagnostic criteria for oral lichen planus. They analyzed the advantages and disadvantages of using this instrument. The 42 patients in group A underwent a conventional biopsy (29 with a scalpel and 13 with a punch). The 42 patients in group B underwent a biopsy performed with the B forceps and a punch. The authors studied artifacts of fragmentation, pseudocysts, crushing, fissures and hemorrhages histologically in both groups. There were no significant differences within group A between the subjects who had undergone either the scalpel or the punch biopsy. There were, however, significant differences between groups A and B. Group B experienced less fragmentation (P = .021), fewer fissures (P = .001) and fewer hemorrhages (P = .001). The new B forceps was a useful aid in the performance of biopsies. It improved visibility and reduced the time needed for the procedure. Biopsy specimens taken with the B forceps also had histologically fewer artifacts than did those taken without the B forceps. This technique using the B forceps has several advantages, including speed, because the ischemia produced by the clamp stabilizes the tissue and increases visibility, facilitating dissection. The time needed for surgical removal thus is shortened.
Astrophysical targets of the Fresnel diffractive imager
NASA Astrophysics Data System (ADS)
Koechlin, L.; Deba, P.; Raksasataya, T.
2017-11-01
The Fresnel Diffractive imager is an innovative concept of distributed space telescope, for high resolution (milli arc-seconds) spectro-imaging in the IR, visible and UV domains. This paper presents its optical principle and the science that can be done on potential astrophysical targets. The novelty lies in the primary optics: a binary Fresnel array, akin to a binary Fresnel zone plate. The main interest of this approach is the relaxed manufacturing and positioning constraints. While having the resolution and imaging capabilities of lens or mirrors of equivalent size, no optical material is involved in the focusing process: just vacuum. A Fresnel array consists of millions void subapertures punched into a large and thin opaque membrane, that focus light by diffraction into a compact and highly contrasted image. The positioning law of the aperture edges drives the image quality and contrast. This optical concept allows larger and lighter apertures than solid state optics, aiming to high angular resolution and high dynamic range imaging, in particular for UV applications. Diffraction focusing implies very long focal distances, up to dozens of kilometers, which requires at least a two-vessel formation flying in space. The first spacecraft, "the Fresnel Array spacecraft", holds the large punched foil: the Fresnel Array. The second, the "Receiver spacecraft" holds the field optics and focal instrumentation. A chromatism correction feature enables moderately large (20%) relative wavebands, and fields of a few to a dozen arc seconds. This Fresnel imager is adapted to high contrast stellar environments: dust disks, close companions and (we hope) exoplanets. Specific to the particular grid-like pattern of the primary focusing zone plate, is the very high dynamic range achieved in the images, in the case of compact objects. Large stellar photospheres may also be mapped with Fresnel arrays of a few meters opertaing in the UV. Larger and more complex fields can be imaged with a lesser dynamic range: galactic or extragalactic, or at the opposite distance scale: small solar system bodies. This paper will briefly address the optical principle, and in more detail the astrophysical missions and targets proposed for a 4-meter class demonstrator: - Exoplanet imaging, Exoplanet spectroscopic analysis in the visible and UV, - Stellar environments, young stellar systems, disks, - Galactic clouds, astrochemistry, - IR observation of the galactic center, - Small objects of our solar system.
Software Testing and Verification in Climate Model Development
NASA Technical Reports Server (NTRS)
Clune, Thomas L.; Rood, RIchard B.
2011-01-01
Over the past 30 years most climate models have grown from relatively simple representations of a few atmospheric processes to a complex multi-disciplinary system. Computer infrastructure over that period has gone from punch card mainframes to modem parallel clusters. Model implementations have become complex, brittle, and increasingly difficult to extend and maintain. Existing verification processes for model implementations rely almost exclusively upon some combination of detailed analysis of output from full climate simulations and system-level regression tests. In additional to being quite costly in terms of developer time and computing resources, these testing methodologies are limited in terms of the types of defects that can be detected, isolated and diagnosed. Mitigating these weaknesses of coarse-grained testing with finer-grained "unit" tests has been perceived as cumbersome and counter-productive. In the commercial software sector, recent advances in tools and methodology have led to a renaissance for systematic fine-grained testing. We discuss the availability of analogous tools for scientific software and examine benefits that similar testing methodologies could bring to climate modeling software. We describe the unique challenges faced when testing complex numerical algorithms and suggest techniques to minimize and/or eliminate the difficulties.
Himalia and Phoebe: Little moons that punch above their weight
NASA Astrophysics Data System (ADS)
LI, Daohai; Christou, Apostolos
2016-05-01
Small bodies in the solar system are usually treated as massless particles. While a sufficient approximation for many purposes, the small but finite mass of some of these (mass ratio μ=10^{-10}-10^{-8} of primary) can have observable consequences on the local population. Numerical experiments have shown this to be true for the orbital neighbourhood of Himalia, a prograde irregular moon of Jupiter (Christou 2005). In a recent demonstration of the same mechanism in a different context, Novaković et al. (2015) showed that the dwarf planet Ceres activates its own secular resonances, causing the long-term diffusion of asteroids in the middle part of the Main Belt.Seeking to better understand the dynamics caused by “internecine” interactions, we have constructed a semi-analytical model of a test particle’s secular evolution in the Sun-Planet-massive moon-particle restricted 4-body problem. By combining the Kozai-Lidov formalism with a model of coorbital motion valid for non-planar & non-circular orbits (Namouni 1999) we have overcome the difficulty in treating the interaction between potentially-crossing neighbouring orbits.We have applied this model to the cases of (a) J6 Himalia, a jovian irregular satellite (μ≃ 2× 10^{-9}) and the largest in a family of five moons, and (b) S9 Phoebe, a retrograde irregular moon of Saturn with μ=1.5× 10^{-8} which, curiously, is not associated with a family (Ćuk et al. 2003). We observe numerous instances of capture into secular resonances where the critical angle is a linear combination of the relative nodes and apses of the particle and the perturber. In particular we are able to reproduce the libration of the differential node found by Christou (2005). We generate fictitious families of test particles around Himalia and Phoebe and find that, while ~8% of local phase space is occupied by these resonances for Himalia, this figure is ~16% for Phoebe. We confirm these results using N-body integrations of the full equations of motion. During the meeting, we will show examples of orbital evolution in the resonances, describe the principal features of the dynamics and discuss the implications for the long-term evolution of families of small bodies.
Kummer, Natalie; Ingels, Ann-Sofie; Wille, Sarah M R; Hanak, Catherine; Verbanck, Paul; Lambert, Willy E E; Samyn, Nele; Stove, Christophe P
2016-01-01
Phosphatidylethanol species (PEths) are promising biomarkers of alcohol consumption. Here, we report on the set-up, validation, and application of a novel UHPLC-ESI-MS/MS method for the quantification of PEth 16:0/18:1, PEth 18:1/18:1, and PEth 16:0/16:0 in whole blood (30 μL) and in venous (V, 30 μL) or capillary (C, 3 punches (3 mm)) dried blood spots (DBS). The methods were linear from 10 (LLOQ) to 2000 ng/mL for PEth 16:0/18:1, from 10 (LLOQ) to 1940 ng/mL for PEth 18:1/18:1, and from 19 (LLOQ) to 3872 ng/mL for PEth 16:0/16:0. Extraction efficiencies were higher than 55% (RSD < 18%) and matrix effects compensated for by IS were between 77 and 125% (RSD < 10%). Accuracy, repeatability, and intermediate precision fulfilled acceptance criteria (bias and RSD below 13%). Validity of the procedure for determination of PEth 16:0/18:1 in blood was demonstrated by the successful participation in a proficiency test. The quantification of PEths in C-DBS was not significantly influenced by the hematocrit, punch localization, or spot volume. The stability of PEths in V-DBS stored at room temperature was demonstrated up to 6 months. The method was applied to authentic samples (whole blood, V-DBS, and C-DBS) from 50 inpatients in alcohol withdrawal and 50 control volunteers. Applying a cut-off value to detect inpatients at 221 ng/mL for PEth 16:0/18:1 provided no false positive results and a good sensitivity (86%). Comparison of quantitative results (Bland-Altman plot, Passing-Bablok regression, and Wilcoxon signed rank test) revealed that V-DBS and C-DBS were valid alternatives to venous blood for the detection of alcohol consumption.
Underwater Grass Comeback Helps Chesapeake Bay
The fortified Susquehanna Flats, the largest bed of underwater grasses in the Chesapeake Bay, seems able to withstand a major weather punch. Its resilience is contributing to an overall increase in the Bay’s submerged aquatic vegetation.
48 CFR 1552.211-73 - Level of effort-cost-reimbursement term contract.
Code of Federal Regulations, 2011 CFR
2011-10-01
... programmers and not support personnel such as company management, typists, and key punch operators even though... specified in paragraph (a) includes Contractor, subcontractor, and consultant labor hours. (c) If the...
DOT National Transportation Integrated Search
1976-08-01
Fare prepayment encompasses all methods of paying for transit rides other than by cash, namely, tickets, tokens, punch cards, passes, and permits. The purpose of this study is the examination of the overall ridership and revenue impacts of ongoing an...
Factors governing hole expansion ratio of steel sheets with smooth sheared edge
NASA Astrophysics Data System (ADS)
Yoon, Jae Ik; Jung, Jaimyun; Lee, Hak Hyeon; Kim, Gyo-Sung; Kim, Hyoung Seop
2016-11-01
Stretch-flangeability measured using hole expansion test (HET) represents the ability of a material to form into a complex shaped component. Despite its importance in automotive applications of advanced high strength steels, stretch-flangeability is a less known sheet metal forming property. In this paper, we investigate the factors governing hole expansion ratio (HER) by means of tensile test and HET. We correlate a wide range of tensile properties with HERs of steel sheet specimens because the stress state in the hole edge region during the HET is almost the same as that of the uniaxial tensile test. In order to evaluate an intrinsic HER of steel sheet specimens, the initial hole of the HET specimen is produced using a milling process after punching, which can remove accumulated shearing damage and micro-void in the hole edge region that is present when using the standard HER evaluation method. It was found that the intrinsic HER of steel sheet specimens was proportional to the strain rate sensitivity exponent and post uniform elongation.
Reclaimed manufacturer asphalt roofing shingles in asphalt mixtures. Final research report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Reed, A.B.
1999-04-23
The purpose of this project was to pave a test section using hot mix asphalt with roofing shingle pieces in the wearing and binder courses and to evaluate. The test project near Allentown, PA plus two other test projects in 1998 provide evidence of very good pavement performance. The bituminous concrete mix was modified with shredded shingles with a maximum size of 1/2 inch which added 1% of the asphalt content. The Department issued a statewide Provisional Specification titled Reclaimed Manufacturer Asphalt Roofing Shingles in Plant-Mixed Bituminous Concrete Courses'' on March 15, 1999. New manufacturer asphalt roofing shingle scrap includingmore » tab punch-outs can be successfully incorporated in bituminous concrete pavements if the shingles are shredded to 100% passing the 3/4 inch sieve. To take full advantage of the potential to replace a portion of the asphalt and therefore, reduce mix costs, shingles should be shredded to 100% passing minus 1/2 inch sieve.« less
Joura, E A; Zeisler, H; Lösch, A; Sator, M O; Müllauer-Ertl, S
1998-08-01
To determine the effectiveness of the toluidine blue test in the differentiation of vulvar intraepithelial neoplasia (VIN) and nonneoplastic epithelial disorders (NNEDs). This retrospective clinical study included all women with VIN (n = 24) and NNED (n = 72) referred to a vulvar clinic at a university hospital during a two-year period. Vulvoscopy, staining of vulvar epithelium with 1% toluidine blue and punch biopsy were performed. Vulvar epithelium demonstrated toluidine blue staining in 100% of the patients with VIN 3, in 83% of women with VIN 1-2, in 50% of the women with squamous cell hyperplasia and in 10% of the women with lichen sclerosus. The differences in staining between the groups were statistically significant (P < .001). The sensitivity of toluidine blue staining for the detection of VIN was 92%; the negative predictive value 96% in teh investigated cohort. The specificity for strong staining was 88%. The toluidine blue test is an inexpensive and reliable method of separating VIN from hyperplastic NNED areas and choosing a biopsy site on the vulva.
NASA Technical Reports Server (NTRS)
Butler, C. M.; Hogge, J. E.
1978-01-01
Air quality sampling was conducted. Data for air quality parameters, recorded on written forms, punched cards or magnetic tape, are available for 1972 through 1975. Computer software was developed to (1) calculate several daily statistical measures of location, (2) plot time histories of data or the calculated daily statistics, (3) calculate simple correlation coefficients, and (4) plot scatter diagrams. Computer software was developed for processing air quality data to include time series analysis and goodness of fit tests. Computer software was developed to (1) calculate a larger number of daily statistical measures of location, and a number of daily monthly and yearly measures of location, dispersion, skewness and kurtosis, (2) decompose the extended time series model and (3) perform some goodness of fit tests. The computer program is described, documented and illustrated by examples. Recommendations are made for continuation of the development of research on processing air quality data.
[A case of acquired immunodeficiency syndrome with ileocecal ulcer].
Iwasaki, Tetsuyoshi; Saruta, Masayuki; Sawada, Ryoichi; Ide, Daisuke; Arihiro, Seiji; Matsuoka, Mika; Katoh, Tomohiro; Tajiri, Hisao
2015-10-01
We report a case of a patient with acquired immunodeficiency syndrome (AIDS) and ileocecal ulcer. A 31-year-old man was admitted with chief complaints of decreased body weight and abdominal pain. Colonoscopy revealed a round punched-out ulcer on the ileocecal valve. Initially, we suspected entero-Behçet's disease and simple ulcer as the cause of the ileocecal ulcer. However, after histologic examination of tissue biopsies obtained during colonoscopy, we diagnosed the patient as having cytomegalovirus (CMV) enteritis. Based on the patient's white blood cell depletion and CMV enteritis, we performed a human immunodeficiency virus (HIV) antibody test. The test was positive, and the diagnosis of AIDS was established. The number of patients with AIDS has been increasing in Japan; thus, we should consider the possibility of CMV enteritis and AIDS in young adult patients affected by ileocecal ulcer with no notable history.
BASSI, M. ANDREASI; ANDRISANI, C.; LICO, S.; SILVESTRE, F.; GARGARI, M.; ARCURI, C.
2016-01-01
SUMMARY Purpose The aim of this article is to make a comparative assessment between the modification of the soft-tissue profile, around the healing cap screws (HCSs), following both the traditional flapless surgery (TFS) and a new modified flapless surgery, named Modified Connective Tissue Punch (MCTP) technique. Materials and methods 8 patients (3M and 5F) (mean age 54.25±11.247 years) were enrolled in this study. Sixteen two-piece implants were placed on upper jaws, 2 for each patient, 8 with TFS and 8 with MCTP technique. In each patient the implants were placed in edentulous areas, of 2 or 3 adjacent teeth long. MCTP technique was performed on the front implant site (FIS) while the TFS was performed on the rear implant site (RIS). All implants were inserted and covered with healing cap screws (HCSs). Alginate impressions were carried out at the moment of the surgery, at 1 month and 4 months post-operative. Plaster models were poured and subsequently digitally scanned, in order to measure the distance between the gingival outline and the free margin of the HCS. The recorded values were analyzed with the ANOVA test. Results The use of MTCP technique, in comparison to TFS, showed a significative better outcome, in terms of vertical increments, of gingiva, on the VS toward the HCSs, during the entire observation period (p = 0.000 for all). Conclusion The Authors recommend the use of MCTP technique for a better vestibular soft tissue outcome in flapless implant surgery. PMID:28042442
Hong, Xinying; Kumar, Arun Babu; Ronald Scott, C; Gelb, Michael H
2018-03-29
All States screen for biotinidase deficiency and galactosemia, and X-linked adrenoleukodystrophy (X-ALD) has recently been added to the Recommended Uniform Screening Panel (RUSP).We sought to consolidate these tests by combining them into a single multiplex tandem mass spectrometry assay as well as to improve the current protocol for newborn screening of galactosemia.A 3 mm punch of a dried blood spot (DBS) was extracted with organic solvent for analysis of the C26:0-lysophosphatidylcholine biomarker for X-ALD.An additional punch was used to assay galactose-1-phosphate uridyltransferase (GALT) and biotinidase.All assays were combined for a single injection for analysis by liquid chromatography-tandem mass spectrometry (LC-MS/MS) (2.3 min per sample).The GALT LC-MS/MS assay does not give a false positive for galactosemia if glucose-6-phosphate dehydrogenase is deficient.The multiplex assay shows acceptable reproducibility and provides for rapid analysis of X-ALD, biotinidase deficiency, and galactosemia.The throughput and ease of sample preparation are acceptable for newborn screening laboratories.We also show that the LC-MS/MS assay is expandable to include several other diseases including Pompe and Hurler diseases (enzymatic activities and biomarkers).Because of consolidation of assays, less manpower is needed compared to running individual assays on separate platforms.The flexibility of the LC-MS/MS platform allows each newborn screening laboratory to analyze the set of diseases offered in their panel. Copyright © 2018 Elsevier Inc. All rights reserved.
Increased hypothalamic protein tyrosine phosphatase 1B contributes to leptin resistance with age.
Morrison, Christopher D; White, Christy L; Wang, Zhong; Lee, Seung-Yub; Lawrence, David S; Cefalu, William T; Zhang, Zhong-Yin; Gettys, Thomas W
2007-01-01
Animals at advanced ages exhibit a reduction in central leptin sensitivity. However, changes in growth, metabolism, and obesity risk occur much earlier in life, particularly during the transition from youth to middle age. To determine when initial decreases in central leptin sensitivity occur, leptin-dependent suppression of food intake was tested in 8-, 12-, and 20-wk-old male, chow-fed Sprague Dawley rats. Intracerebroventricular leptin injection (3 microg) suppressed 24-h food intake in 8- and 12-wk-old rats (P < 0.05) but not 20-wk-old rats. To identify potential cellular mediators of this resistance, we focused on protein tyrosine phosphatase 1B (PTP1B), a recently described inhibitor of leptin signaling. PTP1B protein levels, as determined by Western blot, were significantly higher in mediobasal hypothalamic punches collected from 20-wk-old rats, compared with 8-wk-old rats (P < 0.05). When 20-wk-old rats were fasted for 24 h, levels of hypothalamic PTP1B decreased (P < 0.05), coincident with a restoration of leptin sensitivity. To directly test whether inhibition of PTP1B restores leptin sensitivity, 20-wk-old chow-fed rats were pretreated with a pharmacological PTP1B inhibitor 1 h before leptin, and 24-h food intake was recorded. As expected, leptin alone produced a small but nonsignificant reduction in food intake. However, pretreatment with the PTP1B inhibitor resulted in a marked improvement in leptin-dependent suppression of food intake (P < 0.05). These data are consistent with the hypothesis that increases in PTP1B contribute to hypothalamic leptin resistance as rats transition into middle age.
In vivo degradation of polyethylene liners after gamma sterilization in air.
Kurtz, Steven M; Rimnac, Clare M; Hozack, William J; Turner, Joseph; Marcolongo, Michele; Goldberg, Victor M; Kraay, Matthew J; Edidin, Avram A
2005-04-01
Ultra-high molecular weight polyethylene degrades during storage in air following gamma sterilization, but the extent of in vivo degradation remains unclear. The purpose of this study was to quantify the extent to which the mechanical properties and oxidation of conventional polyethylene acetabular liners treated with gamma sterilization in air change in vivo. Fourteen modular cementless acetabular liners were revised at an average of 10.3 years (range, 5.9 to 13.5 years) after implantation. All liners, which had been machined from GUR 415 resin, had been gamma-sterilized in air; the average shelf life was 0.3 year (range, 0.0 to 0.8 year). After removal, the components were expeditiously frozen to minimize ex vivo changes to the polyethylene prior to characterization. The average duration between freezing and testing was 0.6 year. Mechanical properties and oxidation were measured with use of the small-punch test and Fourier transform infrared spectroscopy, respectively, in the loaded and unloaded regions of the liners. There was substantial regional variation in the mechanical properties and oxidation of the retrieved liners. The ultimate load was observed to vary by >90% near the surface. On the average, the rim and the unloaded bearing showed evidence of severe oxidation near the surface after long-term in vivo aging, but these trends were not typically observed on the loaded bearing surface or near the backside of the liners. The mechanical properties of polyethylene that has been gamma-sterilized in air may decrease substantially in vivo, depending on the location in the liner. The most severe oxidation was observed at the rim, suggesting that the femoral head inhibits access of oxygen-containing body fluids to the bearing surface. This is perhaps why in vivo oxidation has not been associated with clinical performance to date.
Ferré, J; Real, M D; Ménsua, J L; Jacobson, K B
1985-06-25
An unknown fluorescent metabolite has been isolated from heads of eye-color mutants of Drosophila melanogaster. Only a few mutations cause it to accumulate, viz. cardinal (cd), dark red brown (drb), Henna-recessive (Hnr), purple (pr), Punch2 (Pu2), Punch-Grape (PuGr), and scarlet (st). After purification by ion-exchange chromatography, the spectroscopic, chemical, and enzymatic analyses revealed that it is a novel quinoline derivative: xanthurenic acid 8-O-beta-D-glucoside. Feeding experiments suggest that this glucoside is synthesized from 3-hydroxykynurenine and that free xanthurenic acid is not a precursor. The results from the analysis for its occurrence in double mutants, together with the fact that xanthurenic acid 8-glucoside share the same precursor as xanthurenic acid and xanthommatin, suggest that xanthurenic acid 8-glucoside formation is closely related to the regulation of the last step in the biosynthesis of xanthommatin.
6. Photocopy of photograph, U.S. Army, ca. 1955 (original print ...
6. Photocopy of photograph, U.S. Army, ca. 1955 (original print located at Rocky Mountain Arsenal, Commerce City, Colorado). AERIAL VIEW OF BUILDING 1611. VIEW TO NORTHEAST. 'THIS IS THE HONEST JOHN WARHEAD DEMILITARIZATION PLANT. THE DEMILITARIZATION PROCESS CONSISTS OF STRIPPING AND OPENING THE WARHEAD MANUALLY AND DOWNLOADING THE M139 BOMBLETS ONTO A CONVEYOR WHICH CARRIES THEM THROUGH A PUNCH, DRAIN AND RINSE MACHINE INTO A ROTARY RETORT DEACTIVATION FURNACE WHERE THE BURSTER IS BURNED. THE BOMBLET SHELLS, WHICH ARE ALUMINUM, ARE THEN CONVEYED TO A DECONTAMINATION FURNACE WHERE THEY ARE MELTED AND CAST INTO INGOTS. THE GB, WHICH IS COLLECTED IN THE PUNCH, DRAIN AND RINSE MACHINE, IS CONDUCTED TO A STORAGE TANK AND, ULTIMATELY, IS NEUTRALIZED ... - Rocky Mountain Arsenal, Ammunition Demolition Building-Tail Fin Storage & Assembly, 2750 feet South of Ninth Avenue; 3480 feet East of D Street, Commerce City, Adams County, CO
Megasessions for Robotic Hair Restoration.
Pereira, Joa O Carlos; Pereira Filho, Joa O Carlos; Cabrera Pereira, Joa O Pedro
2016-11-01
A robotic system can select and remove individual hair follicles from the donor area with great precision and without fatigue. This report describes the use of the robotic system in a megasession for hair restoration. Patients were instructed to cut their hair to 1.0 to 1.2 mm before surgery. The robot selected and removed 600 to 800 grafts per hour so the follicular units (FU)s could be transplanted manually to recipient sites. The robot arm consists of a sharp inner punch and a blunt outer punch which together separate FUs from the sur- rounding tissue. Stereoscopic cameras controlled by image processing software allow the system to identify the angle and direction of hair growth. The physician and one assistant control the harvesting with a hand-held remote control and computer monitor while the patient is positioned in an adjustable chair. When the robot has harvested all the FUs they are removed by technicians with small forceps. Hairline design, creation of recipient sites, and graft placement are performed manually by the physician. Clinical photographs before and after surgery show that patients experience excellent outcomes with the robotic megasession. Phy- sician fatigue during graft extraction is reduced because the robot performs the repetitive movements without fatigue. Variability of graft extraction is minimized because the robot's optical system can be programmed to choose the best FUs. The transection rate is reduced because the robot's graft extraction system uses two needles, a sharp one to piece the skin and a blunt needle to dissect the root without trauma. A robotic megasession for hair restoration is minimally invasive, does not result in linear scars in the donor area, and is associated with minimal fatigue and discomfort for both patient and physician. Healing is rapid and patients experience a high level of satisfaction with the results. J Drugs Dermatol. 2016;15(11):1407-1412..
NASA Technical Reports Server (NTRS)
Ainsworth, R. W.; Johnson, J. C.; Watts, L. L.
1972-01-01
An investigation was made of the fin configuration and booster body configuration effects on a composite booster/040A orbiter launch configuration. Aerodynamic performance and stability characteristics in pitch and yaw were obtained. Configurations tested included two stepped cylindrical bodies of different lengths with a conical nose, four fin shapes of various sizes and aspect ratios mounted in different positions around the base of the bodies, two base flare angles and three 040A orbiter configurations. The orbiter variations included a tailless configuration and two tail sizes. A tailless booster launch configuration with deflected petals (expanded flare sectors) was also tested. The model scale was 0.003366. Data were converted to coefficient form in near real time, punched on cards, and tabulated. The cards used in conjunction with a Benson-Lehner plotter were used to provide plotted data. At the end of the test, tabulated input forms were completed for the SADSAC computer program to aid in publishing the final test data report.
Computer Plotting Data Points in the Engine Research Building
1956-09-21
A female computer plotting compressor data in the Engine Research Building at the NACA’s Lewis Flight Propulsion Laboratory. The Computing Section was introduced during World War II to relieve short-handed research engineers of some of the tedious data-taking work. The computers made the initial computations and plotted the data graphically. The researcher then analyzed the data and either summarized the findings in a report or made modifications or ran the test again. With the introduction of mechanical computer systems in the 1950s the female computers learned how to encode the punch cards. As the data processing capabilities increased, fewer female computers were needed. Many left on their own to start families, while others earned mathematical degrees and moved into advanced positions.
Fundamental studies on a novel die concept for round-point shear-clinching
NASA Astrophysics Data System (ADS)
Hörhold, Réjane; Müller, Martin; Merklein, Marion; Meschut, Gerson
2016-10-01
A newly-developed round-point shear-clinching technology could increase the use of different materials like well formable aluminium and hardly formable ultra-high-strength steels (UHSS). This innovative technology joins in a single-stage process without any pilot-hole, surface pre-treatment or auxiliary joining part. The combination of an inner and outer punch realises an indirect cutting operation of the die-sided material, whereas the punch-sided material remains unharmed. The current die-sided tool set acts as a cutting die and enables a radial extrusion of the punch-sided material after being drawn though the created hole in the UHSS. The die has a fixed die depth. After ejecting the joined components, the slug has to be removed from the top of the spring-loaded anvil. The novel die concept investigated in this paper offers the possibility to push the slug continuously through the die in the joining direction. The removed slugs remain inside the die, so manual removal is unnecessary. The one-parted tool is supposed to be more robust than the multi-parted one that is currently used. This paper represents the task to evaluate the geometry of a useful shear-clinching die concept. To reduce the experimental effort, FEM should assist the development of the most promising approach. To quantify the success, conventional shear-clinching with opening die acts as a reference. The results show the high potential and the raison d'être of shear-clinching technologies as a mechanical joining technology for future multimaterial applications especially for UHSS.
NASA Astrophysics Data System (ADS)
Marchi, G.; Canti, O.; Baier, V.; Micallef, W.; Hartmann, B.; Alberton, P.; Aszodi, A.; Clausen-Schaumann, H.; Roths, J.
2018-02-01
Fiber optic microindentation sensors that have the potential to be integrated into arthroscopic instruments and to allow localizing degraded articular cartilage are presented in this paper. The indenters consist of optical fibers with integrated Bragg gratings as force sensors. In a basic configuration, the tip of the fiber optic indenter consists of a cleaved fiber end, forming a cylindrical flat punch indenter geometry. When using this indenter geometry, high stresses at the edges of the cylinder are present, which can disrupt the tissue structure. This is avoided with an improved version of the indenter. A spherical indenter tip that is formed by melting the end of the glass fiber. The spherical fiber tip shows the additional advantage of strongly reducing reflections from the fiber end. This allows a reduction of the length of the fiber optic sensor element from 65 mm of the flat punch type to 27 mm of the spherical punch. In order to compare the performance of both indenter types, in vitro stress-relaxation indentation experiments were performed on bovine articular cartilage with both indenter types, to assess biomechanical properties of bovine articular cartilage. For indentation depths between 60 μm and 300 μm, the measurements with both indenter types agreed very well with each other. This shows that both indenter geometries are suitable for microindentation measuremnts . The spherical indenter however has the additional advantage that it minimizes the risk to damage the surface of the tissue and has less than half dimensions than the flat indenter.
Neural Extrapolation of Motion for a Ball Rolling Down an Inclined Plane
La Scaleia, Barbara; Lacquaniti, Francesco; Zago, Myrka
2014-01-01
It is known that humans tend to misjudge the kinematics of a target rolling down an inclined plane. Because visuomotor responses are often more accurate and less prone to perceptual illusions than cognitive judgments, we asked the question of how rolling motion is extrapolated for manual interception or drawing tasks. In three experiments a ball rolled down an incline with kinematics that differed as a function of the starting position (4 different positions) and slope (30°, 45° or 60°). In Experiment 1, participants had to punch the ball as it fell off the incline. In Experiment 2, the ball rolled down the incline but was stopped at the end; participants were asked to imagine that the ball kept moving and to punch it. In Experiment 3, the ball rolled down the incline and was stopped at the end; participants were asked to draw with the hand in air the trajectory that would be described by the ball if it kept moving. We found that performance was most accurate when motion of the ball was visible until interception and haptic feedback of hand-ball contact was available (Experiment 1). However, even when participants punched an imaginary moving ball (Experiment 2) or drew in air the imaginary trajectory (Experiment 3), they were able to extrapolate to some extent global aspects of the target motion, including its path, speed and arrival time. We argue that the path and kinematics of a ball rolling down an incline can be extrapolated surprisingly well by the brain using both visual information and internal models of target motion. PMID:24940874
Neural extrapolation of motion for a ball rolling down an inclined plane.
La Scaleia, Barbara; Lacquaniti, Francesco; Zago, Myrka
2014-01-01
It is known that humans tend to misjudge the kinematics of a target rolling down an inclined plane. Because visuomotor responses are often more accurate and less prone to perceptual illusions than cognitive judgments, we asked the question of how rolling motion is extrapolated for manual interception or drawing tasks. In three experiments a ball rolled down an incline with kinematics that differed as a function of the starting position (4 different positions) and slope (30°, 45° or 60°). In Experiment 1, participants had to punch the ball as it fell off the incline. In Experiment 2, the ball rolled down the incline but was stopped at the end; participants were asked to imagine that the ball kept moving and to punch it. In Experiment 3, the ball rolled down the incline and was stopped at the end; participants were asked to draw with the hand in air the trajectory that would be described by the ball if it kept moving. We found that performance was most accurate when motion of the ball was visible until interception and haptic feedback of hand-ball contact was available (Experiment 1). However, even when participants punched an imaginary moving ball (Experiment 2) or drew in air the imaginary trajectory (Experiment 3), they were able to extrapolate to some extent global aspects of the target motion, including its path, speed and arrival time. We argue that the path and kinematics of a ball rolling down an incline can be extrapolated surprisingly well by the brain using both visual information and internal models of target motion.
Lee, S J; Kim, W Y; Shim, S-H; Cho, S-H; Oh, I K; Hwang, T S; Kim, S-N; Kang, S-B
2015-02-01
This study was performed to evaluate the prognostic significance of human papillomavirus (HPV) viral load, expressed in relative light units (RLUs), in patients with atypical squamous cells of undetermined significance (ASC-US) cytology. A total of 349 ASC-US cases with HPV infection, detected using Hybrid Capture 2, were diagnosed histologically. A colposcopically directed punch biopsy was performed on acetowhite areas. Endocervical curettage biopsy and random cervical punch biopsy in four quadrants were performed in unsatisfactory colposcopy cases. In negative colposcopy cases, random cervical punch biopsy in four quadrants was performed. Case with no cervical intraepithelial neoplasia (CIN), CIN1 and CIN2+ (CIN2/CIN3) accounted for 162, 135 and 52 cases, respectively. The mean age showed no difference among the three groups (P = 0.510). There was a significant correlation between RLU values and the presence of CIN (P < 0.001), but less so with its severity: the median RLU values for negative, CIN1 and CIN2+ cases were 42.68, 146.45 and 156.43, respectively, with widely overlapping confidence intervals. The cut-off values of RLU to detect CIN1+ and CIN2+ were 6.73 and 45.64, respectively. The HPV viral load in ASC-US cases showed a significant correlation with the presence of CIN and less so with its severity, and showed large overlap of viral loads between grades of CIN. In ASC-US cases, RLU was not an accurate predictor of immediate high-grade CIN. © 2014 John Wiley & Sons Ltd.
5. DETAIL VIEW OF OLD, PUNCHTYPE MASTER FIRE ALARM SYSTEM, ...
5. DETAIL VIEW OF OLD, PUNCH-TYPE MASTER FIRE ALARM SYSTEM, LOCATED ON S WALL OF ENGINE STORAGE ROOM; LOOKING S. (Ceronie and Ryan) - Watervliet Arsenal, Building No. 22, Westervelt Avenue & Buffington Street, Watervliet, Albany County, NY
Election 2000: Voting Issues and Recommendations.
ERIC Educational Resources Information Center
Davison, Donald L.
2001-01-01
Focuses on the many issues that the close 2000 presidential election brought to the forefront, such as: problems with the punch card systems, the need for convenient registration, the topic of provisional ballots, and the relevance of the Electoral College. (CMK)
Singer, A J; Berrutti, L; McClain, S A
1999-01-01
A prospective, randomized, blinded, controlled experimental trial was performed in pigs to compare the rates of reepithelialization of 126 full-thickness cutaneous 4-mm punches treated with an octyl-cyanoacrylate spray, silver sulfadiazine, or a dry gauze (controls). Full thickness biopsies were taken 7, 14, or 30 days later for histopathological evaluation of hematoxylin and eosin stained tissue sections by a dermatopathologist. The primary outcome measure was the proportion of wounds completely re-epithelialized at days 7 and 14. Secondary outcomes were the rates of infection, foreign body reactions, and the depth of any resulting cutaneous dells measured with a micrometer. Between-group comparisons were performed with ANOVA or Chi-square tests. Octyl-cyanoacrylate treated wounds re-epithelialized more slowly, as fewer wounds treated with octyl-cyanoacrylate were re-epithelialized at day 7 in comparison with silver sulfadiazine or control wounds (50% vs. 90% vs. 100%, p < 0.001). There were no infections or foreign body type reactions. Amounts of granulation tissue were similar among groups. Octyl-cyanoacrylate wounds were more depressed than silver sulfadiazine wounds at days 7 and 14 yet had similar histopathological characteristics at day 30. We conclude that treatment of small, full thickness cutaneous wounds with octyl-cyanoacrylate results in delayed re-epithelialization and dermal repair in comparison with silver sulfadiazine, yet it does not result in any foreign body-type reaction. However, by 30 days, histopathological wound characteristics were similar in all groups.
Small swimmers and sinkers structure the microenvironment by deforming ambient chemical gradients
NASA Astrophysics Data System (ADS)
Inman, B.; Franks, P. J. S.; Torres, C.
2016-02-01
Chemical gradients in the microscale environment determine the rates of fundamental planktonic processes such as signaling and sensing, grazing, predation, mating, infection, nutrient uptake, and primary production. We show that bodies swimming or sinking at low Reynolds number can deform and intensify ambient scalar gradients on the order of 10-1000 times. Over time, this restructuring of the microenvironment in the wake of a moving particle results in elevated diffusive fluxes of ecologically relevant tracers. We use diffusive Stokes flow to model the time evolution of planes of tracer particles that represent a gradient being deformed by a sinking sphere. Ultimately, the degree of gradient intensification and the corresponding diffusive flux enhancement depend on how far a moving body deforms a plane of tracer before it punches through. We derive a scaling for this distance, Ldef, as a function of the Péclet number and describe its importance in the microscale planktonic environment. We then test the modeled gradient deformation, diffusive flux enhancement, and Ldef using an experimental tank apparatus in which the marine copepod, Calanus pacificus, is induced to swim through a layer of tracer dye. We show that the gradient deformation due to the copepod swimming can enhance the apparent tracer diffusivity by 500% over 10 minutes, drawing the tracer out into centimeters-long tendrils. These swimming-induced gradient deformations may be an important source of structure in the microscale environment of the plankton.
ERIC Educational Resources Information Center
Friesen, Patricia
1993-01-01
College alumni association mailings can be made more successful by targeting the audiences, delivering a strong proposition to readers, choosing a forceful format, and creating impressive copy. Efforts of the University of Minnesota, University of Iowa, and Southern Methodist University illustrate these principles. (MSE)
32. Interior view, encased fireplace and remains of the ...
32. Interior view, encased - fireplace and remains of the hearth against the north wall, with scale l(note: hole punched through plaster allows access to the flues) - Kiskiack, Naval Mine Depot, State Route 238 vicinity, Yorktown, York County, VA
Finite element analyses of railroad tank car head impacts
DOT National Transportation Integrated Search
2008-09-24
This paper describes engineering analyses of a railroad : tank car impacted at its head by a rigid punch. This type of : collision, referred to as a head impact, is examined using : dynamic, nonlinear finite element analysis (FEA). : Commercial softw...
Jones, Charles W.
1981-04-07
A machine for pressing loose powder into pellets using a series of reciprocating motions has an interchangeable punch and die as its only accurately machines parts. The machine reciprocates horizontally between powder receiving and pressing positions. It reciprocates vertically to press, strip and release a pellet.
... portion of the lump is removed surgically. This type of biopsy is most commonly used for tumors of the skin to distinguish benign conditions and diagnose cancers and other tumors. This can be done by 'shave', 'curette' or 'punch' methods. A " shave " slices a surface portion off with ...
NASA Technical Reports Server (NTRS)
Burley, Richard K.; Guirguis, Kamal S.
1991-01-01
Simple, cheap device locks valve stem so its setting cannot be changed by unauthorized people. Device covers valve stem; cover locked in place with standard padlock. Valve lock made of PVC pipe and packing band. Shears, drill or punch, and forming rod only tools needed.
NASA EO-1 Spacecraft Images Chile Volcanic Eruption
2011-06-17
On June 14, 2011, NASA Earth Observing-1 EO-1 spacecraft obtained this image showing ash-rich volcanic plume billowing out of the vent, punching through a low cloud layer. The plume grey color is a reflection of its ash content.
The Early Development of Programmable Machinery.
ERIC Educational Resources Information Center
Collins, Martin D.
1985-01-01
Programmable equipment innovations, precursors of today's technology, are examined, including the development of the binary code and feedback control systems, such as temperature sensing devices, interchangeable parts, punched cards carrying instructions, continuous flow oil refining process, assembly lines for mass production, and the…
Sensitivity of direct immunofluorescence in oral diseases. Study of 125 cases.
Sano, Susana Mariela; Quarracino, María Cecilia; Aguas, Silvia Cristina; González, Ernestina Jesús; Harada, Laura; Krupitzki, Hugo; Mordoh, Ana
2008-05-01
Direct immunofluorescence (DIF) is widely used for the diagnosis of bullous diseases and other autoimmune pathologies such as oral lichen planus. There is no evidence in the literature on how the following variants influence the detection rate of DIF: intraoral site chosen for the biopsy, perilesional locus or distant site from the clinical lesion, number of biopsies and instrument used. to determine if the following variants influenced the sensitivity (detection rate): intraoral site chosen for the biopsy, perilesional or distant site from the clinical lesion, number of biopsies and instrument used (punch or scalpel). A retrospective study was done at the Cátedra de Patología y Clínica Bucodental II at the Facultad de Odontología, Universidad de Buenos Aires; 136 clinical medical histories were revised for the period March 2000 - March 2005 corresponding to patients with clinical diagnosis of OLP and bullous diseases (vulgar pemphigus, bullous pemphigoid and cicatricial pemphigoid). DIF detection rate was 65.8% in patients with OLP, 66.7% in cicatricial pemphigoid patients, in bullous pemphigoid 55.6%, in pemphigus vulgaris 100%, and in those cases in which certain diagnosis could not be obtained, the DIF positivity rate was 45.5% (Pearson chi(2) (4)= 21.5398 Pr= 0.000). There was no statistically significant difference between the different sites of biopsy (Fisher exact test: 0.825). DIF detection rate in perilesional biopsies was 66.1% and in those distant from the site of clinical lesion was 64.7% (Pearson chi(2) v1)= 0.0073 Pr= 0.932. When the number of biopsies were incremented, DIF detection rate also incremented (Pearson chi(2) = 8.7247 Pr= 0.003). The biopsies taken with punch had a higher detection rate than those taken with scalpel (39.1% versus 71.7%) (Pearson chi(2) = 49.0522 Pr= 0.000). While not statistically significant, the tendency outlined in this study indicates there are intraoral regions in which the detection rate of the DIF technique is higher than others: mouth floor, hard palate, superior labial mucosa, ventral face of tongue. This finding could allow a choice of accessible locations and easy operator manipulation, even in distant places from the clinical lesion. Perilesional biopsies have a detection rate similar to those taken distant from the clinical lesion, and those taken with punch have a higher sensitivity rate than those taken with scalpel (both differences were statistically significant).
R&D of A MW-class solid-target for a spallation neutron source
NASA Astrophysics Data System (ADS)
Kawai, Masayoshi; Furusaka, Michihiro; Kikuchi, Kenji; Kurishita, Hiroaki; Watanabe, Ryuzo; Li, Jing-Feng; Sugimoto, Katsuhisa; Yamamura, Tsutomu; Hiraoka, Yutaka; Abe, Katsunori; Hasegawa, Akira; Yoshiie, Masatoshi; Takenaka, Hiroyuki; Mishima, Katsuichiro; Kiyanagi, Yoshiaki; Tanabe, Tetsuo; Yoshida, Naoaki; Igarashi, Tadashi
2003-05-01
R&D for a MW-class solid target composed of tungsten was undertaken to produce a pulsed intense neutron source for a future neutron scattering-facility. In order to solve the corrosion of tungsten, tungsten target blocks were clad with tantalum by means of HIP'ing, brazing and electrolytic coating in a molten salt bath. The applicability of the HIP'ing method was tested through fabricating target blocks for KENS (spallation neutron source at KEK). A further investigation to certify the optimum HIP conditions was made with the small punch test method. The results showed that the optimum temperature was 1500 °C at which the W/Ta interface gave the strongest fracture strength. In the case of the block with a hole for thermocouple, it was found that the fabrication preciseness of a straight hole and a tantalum sheath influenced the results. The development of a tungsten stainless-steel alloy was tried to produce a bare tungsten target, using techniques in powder metallurgy. Corrosion tests for various tungsten alloys were made while varying the water temperature and velocity. The mass loss of tungsten in very slow water at 180 °C was as low as 0.022 mg/y, but increased remarkably with water velocity. Simulation experiments for radiation damage to supplement the STIP-III experiments were made to investigate material hardening by hydrogen and helium, and microstructures irradiated by electrons. Both experiments showed consistent results on the order of the dislocation numbers and irradiation hardness among the different tungsten materials. Thermal-hydraulic designs were made for two types of solid target system of tungsten: slab and rod geometry as a function of the proton beam power. The neutronic performance of a solid target system was compared with that of mercury target based on Monte Carlo calculations by using the MCNP code.
Ahuja, V; Platzek, T; Fink, H; Sonnenburg, A; Stahlmann, R
2010-09-01
Disperse dyes, which are suitable for dyeing synthetic fibres, are responsible for the great majority of allergic contact dermatitis (ACD) cases to textile dyes. The aim of the present study was to investigate the sensitising potential of various disperse dyes using a biphasic protocol of the local lymph node assay (LLNA). Briefly, mice were shaved over a surface of approximately 2 cm(2) on their backs and treated using a "sensitisation-challenge protocol". The shaved surface was treated once daily on days 1-3 with 50 microl of the test solution. Animals remained untreated on days 4-14. On days 15-17, mice were treated with 25 microl of the test solution on the dorsum of both ears. Mice were killed on day 19 with deep CO(2) anaesthesia, the lymph nodes prepared and various end points, such as ear thickness, ear punch weight, lymph node weight, lymph node cell count and the proportion of various lymphocyte subpopulations, were determined by flow cytometry. The results were compared to control group treated with the vehicle alone. Our results showed that almost all of the tested textile dyes caused a significant increase in lymph node cell count and lymph node weight. We also observed an increase in ear thickness and ear punch weight in most of the concentrations tested for various textile dyes. We observed a decrease in CD4+ and CD8+ cells and an increase in CD19+, CD45+ and CD45+/1A+ cells in most of the cases, which is characteristic for allergens. The CD4+/CD69+ cells increased in only few experiments mainly with Disperse Blue 124 and Disperse Blue 106. Based on our results, the disperse dyes could be arranged in four groups on the basis of their sensitising potency in the following decreasing order (in parenthesis: lowest concentration causing a significant increase in lymph node cell number): group 1, strong: Disperse Blue 124 and Disperse Blue 106 (0.003%); group 2, moderate: Disperse Red 1 and Disperse Blue 1 (3%); group 3, weak: Disperse Orange 37 and Disperse Blue 35 (10%); and group 4, very weak: Disperse yellow 3 and Disperse Orange 3 (increase at 30% or no increase at 30%). In conclusion, our study shows that the biphasic LLNA protocol was proficient enough to study the sensitisation potential of tested textile dyes and provides data allowing to discriminate them according to their potency.
Horbert, Victoria; Xin, Long; Foehr, Peter; Brinkmann, Olaf; Bungartz, Matthias; Burgkart, Rainer H; Graeve, T; Kinne, Raimund W
2018-02-01
Objective Limitations of matrix-assisted autologous chondrocyte implantation to regenerate functional hyaline cartilage demand a better understanding of the underlying cellular/molecular processes. Thus, the regenerative capacity of a clinically approved hydrogel collagen type I implant was tested in a standardized bovine cartilage punch model. Methods Cartilage rings (outer diameter 6 mm; inner defect diameter 2 mm) were prepared from the bovine trochlear groove. Collagen implants (± bovine chondrocytes) were placed inside the cartilage rings and cultured up to 12 weeks. Cartilage-implant constructs were analyzed by histology (hematoxylin/eosin; safranin O), immunohistology (aggrecan, collagens 1 and 2), and for protein content, RNA expression, and implant push-out force. Results Cartilage-implant constructs revealed vital morphology, preserved matrix integrity throughout culture, progressive, but slight proteoglycan loss from the "host" cartilage or its surface and decreasing proteoglycan release into the culture supernatant. In contrast, collagen 2 and 1 content of cartilage and cartilage-implant interface was approximately constant over time. Cell-free and cell-loaded implants showed (1) cell migration onto/into the implant, (2) progressive deposition of aggrecan and constant levels of collagens 1 and 2, (3) progressively increased mRNA levels for aggrecan and collagen 2, and (4) significantly augmented push-out forces over time. Cell-loaded implants displayed a significantly earlier and more long-lasting deposition of aggrecan, as well as tendentially higher push-out forces. Conclusion Preserved tissue integrity and progressively increasing cartilage differentiation and push-out forces for up to 12 weeks of cultivation suggest initial cartilage regeneration and lateral bonding of the implant in this in vitro model for cartilage replacement materials.
The `One-Two Punch' of Alcoholism: Role of Central Amygdala Dynorphins / Kappa-Opioid Receptors
Kissler, Jessica L.; Sirohi, Sunil; Reis, Daniel J.; Jansen, Heiko T.; Quock, Raymond M.; Smith, Daniel G.; Walker, Brendan M.
2013-01-01
Background The dynorphin (DYN)/κ-opioid receptor (KOR) system undergoes neuroadaptations following chronic alcohol exposure that promote excessive operant self-administration and negative affective-like states; however, the exact mechanisms are unknown. The present studies tested the hypothesis that an upregulated DYN/KOR system mediates excessive alcohol self-administration that occurs during withdrawal in alcohol-dependent rats by assessing DYN A peptide expression and KOR function, in combination with site-specific pharmacological manipulations. Methods Male Wistar rats were trained to self-administer alcohol using operant behavioral strategies and subjected to intermittent alcohol vapor- or air-exposure. Changes in self-administration were assessed by pharmacological challenges during acute withdrawal. In addition, 22-kHz ultrasonic vocalizations were utilized to measure negative affective-like states. Immunohistochemical techniques assessed DYN A peptide expression and [35S]GTPγS coupling assays were performed to assess KOR function. Results Alcohol-dependent rats displayed increased alcohol self-administration, negative affective-like behavior, DYN A-like immunoreactivity and KOR signaling in the amygdala compared to non-dependent controls. Site-specific infusions of a KOR antagonist selectively attenuated self-administration in dependent rats whereas, a MOR/DOR antagonist cocktail selectively reduced self-administration in non-dependent rats. A MOR antagonist/partial KOR agonist attenuated self-administration in both cohorts. Conclusion Increased DYN A and increased KOR signaling could set the stage for a `one-two punch' during withdrawal that drives excessive alcohol consumption in alcohol-dependence. Importantly, intra-CeA pharmacological challenges functionally confirmed a DYN/KOR system involvement in the escalated alcohol self-administration. Together, the DYN/KOR system is heavily dysregulated in alcohol dependence and contributes to the excessive alcohol consumption during withdrawal. PMID:23611261
[Hand injuries from combat sports].
Hanna, W A; Laier, P
2015-06-01
Each year 3.1% of German adults suffer from accidents related to sports and 75% of the injured athletes are male between 20 and 29 years old. The upper limbs are affected in more than 20% of cases and one third of these injuries involve the hands and fingers. More than half a million athletes are organized in combat sport associations in Germany with an increasing trend. Combat sports are commonly said to have a high risk of injuries to the hand. The aim of this study was to test this hypothesis as well as to describe typical hand injuries associated with combat sports. A systematic review of literature (up to January 2015) in PubMed/Medline and The Cochrane Library as well as a secondary search in the reference lists were carried out. Conclusive comparative studies on the incidence and severity of hand injuries directly related to combat sports action could not be found in the currently available literature. The overall risk of suffering from a sports injury seems to be relatively low in combat sports compared to other sports. Boxing, however, seems to be the most dangerous sport for injuries to the upper extremities and especially the hand. The injury pattern after punching (emergency patients and professional boxers) shows that more than half of these fractures affect the 5th metacarpal and 25% of these are the classical boxer's fracture. This differs significantly from the fracture distribution generally associated with sports, where fractures of the phalanges are the most common. Two rare conditions that may occur as a result of repeated punching are referred to as carpal bossing and boxer's knuckle and excellent results are described for both injury forms after surgical therapy.
NASA Astrophysics Data System (ADS)
Motaman, S. A. H.; Komerla, K.; Storms, T.; Prahl, U.; Brecher, C.; Bleck, W.
2018-05-01
Today, in the automotive industry dual phase (DP) steels are extensively used in the production of various structural parts due to their superior mechanical properties. Hole-flanging of such steels due to simultaneous bending and stretching of sheet metal, is complex and associated with some issues such as strain and strain rate localization, development of micro-cracks, inhomogeneous sheet thinning, etc. In this study an attempt is made to improve the formability of DP sheets, by localized Laser heating. The Laser beam was oscillated in circular pattern rapidly around the pre-hole, blanked prior to the flanging process. In order to investigate formability of DP steel (DP1000), several uniaxial tensile tests were conducted from quasi to intermediate strain rates at different temperatures in warm regime. Additionally, experimentally acquired temperature and strain rate-dependent flow curves were fed into thermomechanical finite element (FE) simulation of the hole-flanging process using the commercial FE software ABAQUS/Explicit. Several FE simulations were performed in order to evaluate the effect of blank's initial temperature and punch speed on deformation localization, stress evolution and temperature distribution in DP1000 sheets during warm hole-flanging process. The experimental and numerical analyses revealed that prescribing a distribution of initial temperature between 300 to 400 °C to the blank and setting a punch speed that accommodates strain rate range of 1 to 5 s-1 in the blank, provides the highest strain hardening capacity in the considered rate and temperature regimes for DP1000. This is in fact largely due to the dynamic strain aging (DSA) effect which occurs due to pinning of mobile dislocations by interstitial solute atoms, particularly at elevated temperatures.
Pfaendler, Krista S.; Mwanahamuntu, Mulindi H.; Sahasrabuddhe, Vikrant V.; Mudenda, Victor; Stringer, Jeffrey S.A.; Parham, Groesbeck P.
2009-01-01
Objective We demonstrate the feasibility of implementing a referral and management system for cryotherapy-ineligible women in a “screen-and-treat” cervical cancer prevention program targeting HIV-infected women in Zambia. Methods We established criteria for patient referral, developed a training program for loop electrosurgical excision procedure (LEEP) providers, and adapted LEEP to a resource-constrained setting. Results We successfully trained 15 nurses to perform visual inspection with acetic acid (VIA) followed by immediate cryotherapy. Women with positive tests but ineligible for cryotherapy were referred for further evaluation. We trained four Zambian physicians to evaluate referrals, perform punch biopsy, LEEP, and manage intra-operative and post-operative complications. From January 2006 through October 2007, a total of 8823 women (41.5% HIV seropositive) were evaluated by nurses in outlying prevention clinics; of these, 1477 (16.7%) were referred for physician evaluation based on established criteria. Of the 875 (59.2% of 1147 referred) that presented for evaluation, 748 (8.4% of total screened) underwent histologic evaluation in the form of punch biopsy or LEEP. Complications associated with LEEP included anesthesia reaction (n=2) which spontaneously resolved, intra-operative (n=12) and post-operative (n=2) bleeding managed by local measures, and post-operative infection (n=12) managed with antibiotics. Conclusion With adaptations for a resource-constrained environment, we have demonstrated that performing LEEP is feasible and safe, with low rates of complications that can be managed locally. It is important to establish referral and management systems using LEEP-based excisional evaluation for women with cryotherapy-ineligible lesions in VIA-based “screen-and-treat” protocols nested within HIV-care programs in resource-constrained settings. PMID:18556050
Pfaendler, Krista S; Mwanahamuntu, Mulindi H; Sahasrabuddhe, Vikrant V; Mudenda, Victor; Stringer, Jeffrey S A; Parham, Groesbeck P
2008-09-01
We demonstrate the feasibility of implementing a referral and management system for cryotherapy-ineligible women in a "screen-and-treat" cervical cancer prevention program targeting HIV-infected women in Zambia. We established criteria for patient referral, developed a training program for loop electrosurgical excision procedure (LEEP) providers, and adapted LEEP to a resource-constrained setting. We successfully trained 15 nurses to perform visual inspection with acetic acid (VIA) followed by immediate cryotherapy. Women with positive tests but ineligible for cryotherapy were referred for further evaluation. We trained four Zambian physicians to evaluate referrals, perform punch biopsy, LEEP, and manage intra-operative and post-operative complications. From January 2006 through October 2007, a total of 8823 women (41.5% HIV seropositive) were evaluated by nurses in outlying prevention clinics; of these, 1477 (16.7%) were referred for physician evaluation based on established criteria. Of the 875 (59.2% of 1147 referred) that presented for evaluation, 748 (8.4% of total screened) underwent histologic evaluation in the form of punch biopsy or LEEP. Complications associated with LEEP included anesthesia reaction (n=2) which spontaneously resolved, intra-operative (n=12) and post-operative (n=2) bleeding managed by local measures, and post-operative infection (n=12) managed with antibiotics. With adaptations for a resource-constrained environment, we have demonstrated that performing LEEP is feasible and safe, with low rates of complications that can be managed locally. It is important to establish referral and management systems using LEEP-based excisional evaluation for women with cryotherapy-ineligible lesions in VIA-based "screen-and-treat" protocols nested within HIV-care programs in resource-constrained settings.
Analysis of soft magnetic materials by electron backscatter diffraction as a powerful tool
NASA Astrophysics Data System (ADS)
Schuller, David; Hohs, Dominic; Loeffler, Ralf; Bernthaler, Timo; Goll, Dagmar; Schneider, Gerhard
2018-04-01
The current work demonstrates that electron backscatter diffraction (EBSD) is a powerful and versatile characterization technique for investigating soft magnetic materials. The properties of soft magnets, e.g., magnetic losses strongly depend on the materials chemical composition and microstructure, including grain size and shape, texture, degree of plastic deformation and elastic strain. In electrical sheet stacks for e-motor applications, the quality of the machined edges/surfaces of each individual sheet is of special interest. Using EBSD, the influence of the punching process on the microstructure at the cutting edge is quantitatively assessed by evaluating the crystallographic misorientation distribution of the deformed grains. Using an industrial punching process, the maximum affected deformation depth is determined to be 200 - 300 μm. In the case of laser cutting, the affected deformation depth is determined to be approximately zero. Reliability and detection limits of the developed EBSD approach are evaluated on non-affected sample regions and model samples containing different indentation test bodies. A second application case is the investigation of the recrystallization process during the annealing step of soft magnetic composites (SMC) toroids produced by powder metallurgy as a function of compaction pressure, annealing parameters and powder particle size. With increasing pressure and temperature, the recrystallized area fraction (e.g., grains with crystallographic misorientations < 3°) increases from 71 % (200 MPa, 800°C) to 90% (800 MPa, 800°C). Recrystallization of the compacted powder material starts at the particle boundaries or areas with existing plastic deformation. The progress of recrystallization is visualized as a function of time and of different particle to grain size distributions. Here, large particles with coarse internal grain structures show a favorable recrystallization behavior which results in large bulk permeability of up to 600 - 700 and lower amount of residual misorientations (>3°).
Reproducibility of the Internal Load and Performance-Based Responses to Simulated Amateur Boxing.
Thomson, Edward D; Lamb, Kevin L
2017-12-01
Thomson, ED and Lamb, KL. Reproducibility of the internal load and performance-based responses to simulated amateur boxing. J Strength Cond Res 31(12): 3396-3402, 2017-The aim of this study was to examine the reproducibility of the internal load and performance-based responses to repeated bouts of a three-round amateur boxing simulation protocol (boxing conditioning and fitness test [BOXFIT]). Twenty-eight amateur boxers completed 2 familiarization trials before performing 2 complete trials of the BOXFIT, separated by 4-7 days. To characterize the internal load, mean (HRmean) and peak (HRpeak) heart rate, breath-by-breath oxygen uptake (V[Combining Dot Above]O2), aerobic energy expenditure, excess carbon dioxide production (CO2excess), and ratings of perceived exertion were recorded throughout each round, and blood lactate determined post-BOXFIT. Additionally, an indication of the performance-based demands of the BOXFIT was provided by a measure of acceleration of the punches thrown in each round. Analyses revealed there were no significant differences (p > 0.05) between repeated trials in any round for all dependent measures. The typical error (coefficient variation %) for all but 1 marker of internal load (CO2excess) was 1.2-16.5% and reflected a consistency that was sufficient for the detection of moderate changes in variables owing to an intervention. The reproducibility of the punch accelerations was high (coefficient of variance % range = 2.1-2.7%). In general, these findings suggest that the internal load and performance-based efforts recorded during the BOXFIT are reproducible and, thereby, offer practitioners a method by which meaningful changes impacting on performance could be identified.
ERIC Educational Resources Information Center
Van Hesteren, Frank
1995-01-01
Reacts to Martin's (1995) essay concerning scientism in psychotherapy. Urges placing a moratorium on the "hermeneutic retreat" advocated by Martin, and urges capitalizing on the unique strengths of both positivistic and interpretive modes of inquiry. (JPS)
Hurricane Matthew over Haiti seen by NASA's MISR
Atmospheric Science Data Center
2017-04-18
... but part of the Bahamas is visible to the north. Several hot towers are visible within the central part of the storm, and another at the top right of the image. Hot towers are enormous thunderheads that punch through the tropopause (the ...
Galaxy Packs Big Star-Making Punch
2013-04-23
The tiny red spot in this image is one of the most efficient star-making galaxies ever observed, converting gas into stars at the maximum possible rate. The galaxy is shown here is from NASA WISE, which first spotted the rare galaxy in infrared light.
21 CFR 876.1075 - Gastroenterology-urology biopsy instrument.
Code of Federal Regulations, 2010 CFR
2010-04-01
... generic type of device includes the biopsy punch, gastrointestinal mechanical biopsy instrument, suction... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gastroenterology-urology biopsy instrument. 876... Gastroenterology-urology biopsy instrument. (a) Identification. A gastroenterology-urology biopsy instrument is a...
21 CFR 876.1075 - Gastroenterology-urology biopsy instrument.
Code of Federal Regulations, 2011 CFR
2011-04-01
... generic type of device includes the biopsy punch, gastrointestinal mechanical biopsy instrument, suction... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Gastroenterology-urology biopsy instrument. 876... Gastroenterology-urology biopsy instrument. (a) Identification. A gastroenterology-urology biopsy instrument is a...
Characterization of the punching shear capacity of thin ultra-high performance concrete slabs.
DOT National Transportation Integrated Search
2005-01-01
Ultra-high performance concrete (UHPC) is a relatively new type of concrete that exhibits mechanical properties that are far superior to those of conventional concrete and in some cases rival those of steel. The main characteristics that distinguish ...
Characterization of Metacarpal Fractures in a Military Population.
Dichiera, Robert; Dunn, John; Bader, Julia; Bulken-Hoover, Jamie; Pallis, Mark
2016-08-01
The purpose of this study was to investigate the incidence and type of metacarpal (MC) fractures in a military population, and whether these fractures are related to age, military occupational specialty, aggression, or accidental injury. A retrospective record-based review was conducted at a single military center over a 5-year period. Service members with index finger through small finger MC fracture were identified. Data were collected utilizing Armed Forces Health Longitudinal Technology Application and electronic profile (e-profile) databases. Data collected included demographic information, mechanism of injury, nature of injury, total number of visits, and estimated time on physical restriction. 400 patients met inclusion criteria. Males accounted for 94% of the study population, 75% of fractures were of the small finger MC, 54% of patients were between 20 and 24 years, 90% were sustained by junior enlisted personnel, and most occurred by punching. Men aged <25 years were more likely to have intentional injuries. Total time on limited duty profile averaged 38 days and the average medically nondeployable profile was 26 days. MC fractures most commonly affect young, male, junior enlisted service members and are often self-inflicted. As a result, these injuries account for time lost at work, reduced job performance, and decreased medical readiness. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.
Sherman, M E; Schiffman, M H; Lorincz, A T; Herrero, R; Hutchinson, M L; Bratti, C; Zahniser, D; Morales, J; Hildesheim, A; Helgesen, K; Kelly, D; Alfaro, M; Mena, F; Balmaceda, I; Mango, L; Greenberg, M
1997-04-25
Several new techniques have been developed to improve the sensitivity of cervical carcinoma screening and reduce equivocal cytologic diagnoses referred to as atypical squamous cells of undetermined significance (ASCUS). This study evaluates the effectiveness of combining two newly introduced diagnostic techniques: preparation of thin-layer cytologic slides from ThinPrep liquid buffer and selected Hybrid Capture testing for human papillomavirus (HPV) DNA. Because HPV DNA detection has been strongly associated with the presence of a cervical carcinoma precursor ("squamous intraepithelial lesion," or SIL), HPV testing might be useful for identifying women with ASCUS who have an underlying SIL. Two hundred specimens demonstrating diverse cervical abnormalities were selected from a prospective population-based study of 9174 women conducted in Costa Rica. The entire cohort had been screened with conventional cervical smears; ThinPrep slides made from liquid buffer, PAPNET, a computerized slide reading system; and Cervicography. Patients with any abnormal screening test were referred for colposcopy, punch biopsy, and loop excision of cases with high grade cytologic abnormalities not explained by punch biopsy. For this investigation, the results of ThinPrep cytology and HPV testing alone and in combination were compared with the final diagnoses, with an emphasis on the detection of carcinoma and high grade SIL. The 200 subjects studied included 7 women with a final diagnosis of carcinoma, 44 with high grade SIL, 34 with low grade SIL, 51 with a variety of equivocal diagnoses, and 64 with normal diagnoses. A ThinPrep cytologic diagnosis of SIL or carcinoma was made in 39 (76%) of the 51 women with final diagnoses of high grade SIL or carcinoma. Hybrid Capture testing detected carcinoma-associated types of HPV DNA in 100% of women with carcinoma, 75% with high grade SIL, 62% with low grade SIL, 20% with equivocal final diagnoses, and 12% of normal women. If colposcopy referral had been limited to women with a ThinPrep diagnosis of SIL or a diagnosis of ASCUS associated with the detection of carcinoma-associated HPV DNA from the same vial, 100% of women with carcinoma and 80% with high grade SIL would have been examined. To achieve this high sensitivity in the entire population of 9174 women would have required the referral of about 7% of the population. The combined screening strategy would have performed marginally better than optimized conventional screening with referral of any abnormal cytology (ASCUS and above). A cervical carcinoma screening technique which uses a single sample for cytopathology and HPV testing to triage equivocal diagnoses may be promising if it proves to be cost-effective.
Direct Y-STR amplification of body fluids deposited on commonly found crime scene substrates.
Dargay, Amanda; Roy, Reena
2016-04-01
Body fluids detected on commonly found crime scene substrates require extraction, purification and quantitation of DNA prior to amplification and generation of short tandem repeat (STR) DNA profiles. In this research Y-STR profiles were generated via direct amplification of blood and saliva deposited on 12 different substrates. These included cigarette butts, straws, grass, leaves, woodchips and seven different types of fabric. After depositing either 0.1 μL of blood or 0.5 μL of saliva, each substrate containing the dry body fluid stain was punched using a Harris 1.2 mm micro-punch. Each of these punched substrates, a total of 720 samples, containing minute amount of blood or saliva was either amplified directly without any pre-treatment, or was treated with one of the four washing reagents or buffer. In each of these five experimental groups the substrates containing the body fluid remained in the amplification reagent during the thermal cycling process. Each sample was amplified with the three direct Y-STR amplification kits; AmpFℓSTR(®) Yfiler(®) Direct, Yfiler(®) Plus Amplification Kits and the PowerPlex(®) Y23 System. Complete and concordant Y-STR profiles were successfully obtained from most of these 12 challenging crime scene objects when the stains were analyzed by at least one of the five experimental groups. The reagents and buffer were interchangeable among the three amplification kits, however, pre-treatment with these solutions did not appear to enhance the quality or the number of the full profiles generated with direct amplification. This study demonstrates that blood and saliva deposited on these simulated crime scene objects can be amplified directly. Copyright © 2016 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.
Multimodal US-gamma imaging using collaborative robotics for cancer staging biopsies.
Esposito, Marco; Busam, Benjamin; Hennersperger, Christoph; Rackerseder, Julia; Navab, Nassir; Frisch, Benjamin
2016-09-01
The staging of female breast cancer requires detailed information about the level of cancer spread through the lymphatic system. Common practice to obtain this information for patients with early-stage cancer is sentinel lymph node (SLN) biopsy, where LNs are radioactively identified for surgical removal and subsequent histological analysis. Punch needle biopsy is a less invasive approach but suffers from the lack of combined anatomical and nuclear information. We present and evaluate a system that introduces live collaborative robotic 2D gamma imaging in addition to live 2D ultrasound to identify SLNs in the surrounding anatomy. The system consists of a robotic arm equipped with both a gamma camera and a stereoscopic tracking system that monitors the position of an ultrasound probe operated by the physician. The arm cooperatively places the gamma camera parallel to the ultrasound imaging plane to provide live multimodal visualization and guidance. We validate the system by evaluating the target registration errors between fused nuclear and US image data in a phantom consisting of two spheres, one of which is filled with radioactivity. Medical experts perform punch biopsies on agar-gelatine phantoms with complex configurations of hot and cold lesions to provide a qualitative and quantitative evaluation of the system. The average point registration error for the overlay is [Formula: see text] mm. The time of the entire procedure was reduced by 36 %, with 80v of the biopsies being successful. The users' feedback was very positive, and the system was deemed to be very intuitive, with handling similar to classic US-guided needle biopsy. We present and evaluate the first medical collaborative robotic imaging system. Feedback from potential users for SLN punch needle biopsy is encouraging. Ongoing work investigates the clinical feasibility with more complex and realistic phantoms.
Sodium bicarbonate ingestion and boxing performance.
Siegler, Jason C; Hirscher, Kristian
2010-01-01
Boxing is a sport that consists of multiple high-intensity bouts separated by minimal recovery time and may benefit from a pre-exercise alkalotic state. The purpose of this study was to observe the ergogenic potential of sodium bicarbonate (NaHCO3) ingestion on boxing performance. Ten amateur boxers volunteered to participate in 2 competitive sparring bouts. The boxers were prematched for weight and boxing ability and consumed either 0.3 g.kg(-1) body weight (BW) of NaHCO3 (BICARB) or 0.045 g.kg(-1) BW of NaCl placebo (PLAC) mixed in diluted low calorie-flavored cordial. The sparring bouts consisted of four 3-minute rounds, each separated by 1-minute seated recovery. Blood acid-base (pH, bicarbonate [HCO3(-)], base excess [BE]), and performance (rates of perceived exertion [RPE], heart rate [HR] [HR(ave) and HR(max)], total punches landed successfully) profiles were analyzed before (where applicable) and after sparring. The results indicated a significant interaction effect for HCO3(-) (p < or = 0.001) and BE (p < 0.001), but not for pH (p = 0.48). Post hoc analysis revealed higher presparring HCO3(-) and BE for the BICARB condition, but no differences between the BICARB and PLAC conditions postsparring. There was a significant increase in punches landed during the BICARB condition (p < 0.001); however, no significant interaction effects for HRave (p = 0.15), HRmax (p = 0.32), or RPE (p = 0.38). The metabolic alkalosis induced by the NaHCO3 loading elevated before and after sparring blood buffering capacity. In practical application, the findings suggest that a standard NaHCO3 loading dose (0.3 g.kg(-1)) improves punch efficacy during 4 rounds of sparring performance.
Hosono, Kanako; Isonaka, Risa; Kawakami, Tadashi; Narumiya, Shuh; Majima, Masataka
2016-01-01
Lymphangiogenesis plays an important role in homeostasis, metabolism, and immunity, and also occurs during wound-healing. Here, we examined the roles of prostaglandin E2 (PGE2) receptor (EP) signaling in enhancement of lymphangiogenesis in wound healing processes. The hole-punch was made in the ears of male C57BL/6 mice using a metal ear punch. Healing process and lymphangiogenesis together with macrophage recruitment were analyzed in EP knockout mice. Lymphangiogenesis was up-regulated in the granulation tissues at the margins of punched-hole wounds in mouse ears, and this increase was accompanied by increased expression levels of COX-2 and microsomal prostaglandin E synthase-1. Administration of celecoxib, a COX-2 inhibitor, suppressed lymphangiogenesis in the granulation tissues and reduced the induction of the pro-lymphangiogenic factors, vascular endothelial growth factor (VEGF) -C and VEGF-D. Topical applications of selective EP receptor agonists enhanced the expressions of lymphatic vessel endothelial hyaluronan receptor-1 and VEGF receptor-3. The wound-healing processes and recruitment of CD11b-positive macrophages, which produced VEGF-C and VEGF-D, were suppressed under COX-2 inhibition. Mice lacking either EP3 or EP4 exhibited reduced wound-healing, lymphangiogenesis and recruitment of M2 macrophages, compared with wild type mice. Proliferation of cultured human lymphatic endothelial cells was not detected under PGE2 stimulation. Lymphangiogenesis and recruitment of M2 macrophages that produced VEGF-C/D were suppressed in mice treated with a COX-2 inhibitor or lacking either EP3 or EP4 during wound healing. COX-2 and EP3/EP4 signaling may be novel targets to control lymphangiogenesis in vivo.
[Industrial sound spectrum entailing noise-induced occupational hearing loss in Iasi industry].
Carp, Cristina Maria; Costinescu, V N
2011-01-01
In European Union every day millions of employees are exposed to noise at work and the risk this can entail. this study presents the sound spectrum in Iasi heavy industry: metal foundries industry, punching and embossing of metal sheets, cold and hot metal processing. it was used a type 2 Sound Level Meter (SLM) and the considered value was the average value over 10 test values in 10 consecutive days for each octave band in common audible frequency range. It is obviously that the large values of sound intensities in the most of frequency octave band exceed maximum admissible and legal values. The study reveals the necessity of hardware, medical and managerial measures in order to reduce the occupational noise and to prevent the hearing acuity damage of the workers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hankin, G.L.; Hamilton, M.L.; Gelles, D.S.
1997-04-01
The yield and maximum strengths of an irradiated series of isotopically tailored ferritic alloys were evaluated using the shear punch test. The composition of three of the alloys was Fe-12Cr-1.5Ni. Different balances of nickel isotopes were used in each alloy in order to produce different helium levels. A fourth alloy, which contained no nickel, was also irradiated. The addition of nickel at any isotopic balance to the Fe-12Cr base alloy significantly increased the shear yield and maximum strengths of the alloys, and as expected, the strength of the alloys decreased with increasing irradiation temperature. Helium itself, up to 75 appmmore » over 7 dpa appears to have little effect on the mechanical properties of the alloys.« less
ERIC Educational Resources Information Center
Grech, Norma; And Others
Developed as part of the Connecticut Migratory Children's Program and for other students whose native language is Spanish, this illustrated cookbook contains 12 Puerto Rican recipes with step-by-step instructions (fruit drink, limbers, pina colada, punch, banana shake, amarillos fritos, avocado salad, tortilla de huevos, sweet corn cereal, rice…
NASA Technical Reports Server (NTRS)
Senter, H. F.
1984-01-01
Tool alines center of new hold with existing hole. Tool marks center of new hole drilled while workpiece is in place. Secured with bolts while hole center marked with punch. Used for field installations where reference points unavailable or work area cramped and not easily accessible with conventional tools.
A Short History of the Computer.
ERIC Educational Resources Information Center
Leon, George
1984-01-01
Briefly traces the development of computers from the abacus, John Napier's logarithms, the first computer/calculator (known as the Differential Engine), the first computer programming via steel punched cards, the electrical analog computer, electronic digital computer, and the transistor to the microchip of today's computers. (MBR)
21 CFR 874.4420 - Ear, nose, and throat manual surgical instrument.
Code of Federal Regulations, 2010 CFR
2010-04-01
... device includes the esophageal dilator; tracheal bistour (a long, narrow surgical knife); tracheal dilator; tracheal hook; laryngeal injection set; laryngeal knife; laryngeal saw; laryngeal trocar...; wire ear loop; microrule; mirror; mobilizer; ear, nose, and throat punch; ear, nose and throat knife...
21 CFR 886.4350 - Manual ophthalmic surgical instrument.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Manual ophthalmic surgical instrument. 886.4350 Section 886.4350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... suturing needle, lachrymal probe, trabeculotomy probe, cornea-sclera punch, ophthalmic retractor...
Mayer, Carl; Li, Nan; Mara, Nathan Allan; ...
2014-11-07
Nanolaminate composites show promise as high strength and toughness materials. Still, due to the limited volume of these materials, micron scale mechanical testing methods must be used to determine the properties of these films. To this end, a novel approach combining a double notch shear testing geometry and compression with a flat punch in a nanoindenter was developed to determine the mechanical properties of these films under shear loading. To further elucidate the failure mechanisms under shear loading, in situ TEM experiments were performed using a double notch geometry cut into the TEM foil. Aluminum layer thicknesses of 50nm andmore » 100nm were used to show the effect of constraint on the deformation. Higher shear strength was observed in the 50 nm sample (690±54 MPa) compared to the 100 nm sample (423±28.7 MPa). Additionally, failure occurred along the Al-SiC interface in the 50 nm sample as opposed to failure within the Al layer in the 100 nm sample.« less
Deep drawing of 304 L Steel Sheet using Vegetable oils as Forming Lubricants
NASA Astrophysics Data System (ADS)
Shashidhara, Y. M.; Jayaram, S. R.
2012-12-01
The study involves the evaluation of deep drawing process using two non edible oils, Pongam (Pongammia pinnata) and Jatropha (Jatropha carcass) as metal forming lubricants. Experiments are conducted on 304L steel sheets under the raw and modified oils with suitable punch and die on a hydraulic press of 200 ton capacity. The punch load, draw-in-length and wall thickness distribution for deep drawn cups are observed. The drawn cups are scanned using laser scanning technique and 3D models are generated using modeling package. The wall thickness profiles of cups at different sections (or height) are measured using CAD package. Among the two raw oils, the drawn cups under Jatropha oil, have uniform wall thickness profile compared to Pongam oil. Uneven flow of material and cup rupturing is observed under methyl esters of Pongam and Jatropha oil lubricated conditions. However, the results are observed under epoxidised Jatropha oil with uniform metal flow and wall thicknesses compared to mineral and other versions of vegetable oils.
Reduction of Powerplex(®) Y23 reaction volume for genotyping buccal cell samples on FTA(TM) cards.
Raziel, Aliza; Dell'Ariccia-Carmon, Aviva; Zamir, Ashira
2015-01-01
PowerPlex(®) Y23 is a novel kit for Y-STR typing that includes new highly discriminating loci. The Israel DNA Database laboratory has recently adopted it for routine Y-STR analysis. This study examined PCR amplification from 1.2-mm FTA punch in reduced volumes of 5 and 10 μL. Direct amplification and washing of the FTA punches were examined in different PCR cycle numbers. One short robotically performed wash was found to improve the quality and the percent of profiles obtained. The optimal PCR cycle number was determined for 5 and 10 μL reaction volumes. The percent of obtained profiles, color balance, and reproducibility were examined. High-quality profiles were achieved in 90% and 88% of the samples amplified in 5 and 10 μL, respectively, in the first attempt. Volume reduction to 5 μL has a vast economic impact especially for DNA database laboratories. © 2014 American Academy of Forensic Sciences.
Evaluation of Direct PCR Amplification Using Various Swabs and Washing Reagents.
Altshuler, Hallie; Roy, Reena
2015-11-01
DNA profiles were generated via direct amplification from blood and saliva samples deposited on various types of swab substrates. Each of the six non-FTA substrates used in this research was punched with a Harris 1.2 mm puncher. After 0.1 μL of blood or 0.5 μL saliva, samples were deposited on each of these punches, samples were pretreated with one of four buffers and washing reagents. Amplification was performed using direct and nondirect autosomal and Y-STR kits. Autosomal and Y-STR profiles were successfully generated from most of these substrates when pretreated with buffer or washing reagents. Concordant profiles were obtained within and between the six substrates, the six amplification kits, and all four reagents. The direct amplification of substrates which do not contain lysing agent would be beneficial to the forensic community as the procedure can be used on evidence samples commonly found at crime scenes. © 2015 American Academy of Forensic Sciences.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salajegheh, Nima; Abedrabbo, Nader; Pourboghrat, Farhang
An efficient integration algorithm for continuum damage based elastoplastic constitutive equations is implemented in LS-DYNA. The isotropic damage parameter is defined as the ratio of the damaged surface area over the total cross section area of the representative volume element. This parameter is incorporated into the integration algorithm as an internal variable. The developed damage model is then implemented in the FEM code LS-DYNA as user material subroutine (UMAT). Pure stretch experiments of a hemispherical punch are carried out for copper sheets and the results are compared against the predictions of the implemented damage model. Evaluation of damage parameters ismore » carried out and the optimized values that correctly predicted the failure in the sheet are reported. Prediction of failure in the numerical analysis is performed through element deletion using the critical damage value. The set of failure parameters which accurately predict the failure behavior in copper sheets compared to experimental data is reported as well.« less
Acute fatal coronary artery dissection following exercise-related blunt chest trauma.
Barbesier, Marie; Boval, Catherine; Desfeux, Jacques; Lebreton, Catherine; Léonetti, Georges; Piercecchi, Marie-Dominique
2015-01-01
Coronary artery injury such as acute coronary dissection is an uncommon and potentially life-threatening complication after blunt chest trauma. The authors report an unusual autopsy case of a 43-year-old healthy man who suddenly collapsed after receiving a punch to the chest during the practice of kung fu. The occurrence of the punch was supported by the presence of one recent contusion on the left lateral chest area at the external examination and by areas of hemorrhage next to the left lateral intercostal spaces at the internal examination. The histological examination revealed the presence of an acute dissection of the proximal segment of the left anterior descending coronary artery. Only few cases of coronary artery dissection have been reported due to trauma during sports activities such as rugby and soccer games, but never during the practice of martial arts, sports usually considered as safe and responsible for only minor trauma. © 2014 American Academy of Forensic Sciences.
Šašiċ, Slobodan; Ojakovo, Peter; Warman, Martin; Sanghvi, Tapan
2013-09-01
Raman chemical mapping was used to determine the distribution of magnesium stearate, a lubricant, on the surface of tablets. The lubrication was carried out via a punch-face lubrication system with different spraying rates applied on placebo and active-containing tablets. Principal component analysis was used for decomposing the matrix of Raman mapping spectra. Some of the loadings associated with minuscule variation in the data significantly overlap with the Raman spectrum of magnesium stearate in placebo tablets and allow for imaging the domains of magnesium stearate via corresponding scores. Despite the negligible variation accounted for by respective principal components, the score images seem reliable as demonstrated through thresholding the one-dimensional representation and the spectra of the hot pixels that show a weak but perceivable magnesium stearate band at 1295 cm(-1). The same approach was applied on the active formulation, but no magnesium stearate was identified, presumably due to overwhelming concentration and spectral contribution of the active pharmaceutical ingredient.
Ackerson, J.R.; Schmitt, C.J.; McKee, M.J.; Brumbaugh, W.G.
2013-01-01
A non-lethal biopsy method for monitoring mercury (Hg) concentrations in smallmouth bass (Micropterus dolomieu; smallmouth) from the Eleven Point River in southern Missouri USA was evaluated. A biopsy punch was used to remove a muscle tissue plug from the area immediately below the anterior dorsal fin of 31 smallmouth. An additional 35 smallmouth (controls) were held identically except that no tissue plug was removed. After sampling, all fish were held in a concrete hatchery raceway for 6 weeks. Mean survival at the end of the holding period was 97 % for both groups. Smallmouth length, weight and Fulton’s condition factor at the end of the holding period were also similar between plugged and non-plugged controls, indicating that the biopsy procedure had minimal impact on growth under these conditions. Tissue plug Hg concentrations were similar to smallmouth Hg data obtained in previous years by removing the entire fillet for analysis.
Ackerson, R.J.; McKee, J.M.; Schmitt, C.J.; Brumbaugh, William G.
2014-01-01
A non-lethal biopsy method for monitoring mercury (Hg) concentrations in smallmouth bass (Micropterus dolomieu; smallmouth) from the Eleven Point River in southern Missouri USA was evaluated. A biopsy punch was used to remove a muscle tissue plug from the area immediately below the anterior dorsal fin of 31 smallmouth. An additional 35 smallmouth (controls) were held identically except that no tissue plug was removed. After sampling, all fish were held in a concrete hatchery raceway for 6 weeks. Mean survival at the end of the holding period was 97 % for both groups. Smallmouth length, weight and Fulton’s condition factor at the end of the holding period were also similar between plugged and non-plugged controls, indicating that the biopsy procedure had minimal impact on growth under these conditions. Tissue plug Hg concentrations were similar to smallmouth Hg data obtained in previous years by removing the entire fillet for analysis.
Simulation studies on Tube End Expansion of AA2014 Alloy Tubes
NASA Astrophysics Data System (ADS)
Venugopal, L.; Prasad, N. E. C.; Geeta Krishna, P.; Praveen, L.
2018-03-01
End forming is defined as forming the end of tubular forms either by inverting the tube or by expanding it. It finds application in many fields such as in automotive and aerospace sectors as power transmission elements, fuel lines, exhaust pipes etc. The main aim of the present work is to expand the AA2014 alloy tubes with different die sets without any fracture. Deform 2D software was used for performing simulations on expanding the tubes with different die set (punch) values having differed forming angles (α = 15°, 30° and 45°) and expansion ratios (rp/r0 = 1.39, 1.53 and 1.67). Experiments were also conducted and the results correlate with the simulation results. The results shows that for the punch having less cone angle (α) values the linear displacement is more rather than higher cone angles. But in the case of higher cone angles the radial displacement is more than the linear displacement.
Preliminary Investigation of the Process Capabilities of Hydroforging
Alzahrani, Bandar; Ngaile, Gracious
2016-01-01
Hydroforging is a hybrid forming operation whereby a thick tube is formed to a desired geometry by combining forging and hydroforming principles. Through this process hollow structures with high strength-to-weight ratio can be produced for applications in power transmission systems and other structural components that demands high strength-to-weight ratio. In this process, a thick tube is deformed by pressurized fluid contained within the tube using a multi-purpose punch assembly, which is also used to feed tube material into the die cavity. Fluid pressure inside the thick tube is developed by volume change governed by the movement of the punch assembly. In contrast to the conventional tube hydroforming (THF), the hydroforging process presented in this study does not require external supply of pressurized fluid to the deforming tube. To investigate the capability of hydroforging process, an experimental setup was developed and used to hydroforge various geometries. These geometries included hollow flanged vessels, hexagonal flanged parts, and hollow bevel and spur gears. PMID:28787840
Effect of Equal Biaxial Pre-Strain on Forming Limit Diagram of AA5083
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhalehfar, F.; Hosseinipour, S. J.; Nourouzi, S.
In this work, the effect of equal biaxial pre-strain on the forming limit curve (FLC) of 5083 aluminum alloy has been investigated. For this purpose, in the first stage, square blanks with dimensions of 200 mm in each length were cut from the original sheet and stretched by a spherical punch to the specified heights. Then, specimens were prepared by cutting the pre-strained blanks with the longitudinal axis parallel and perpendicular to the rolling direction. In the second stage, the specimens were tested by the out-of-plane test method to determine the forming limit diagram (FLD) according to the ISO 12004.more » Furthermore, forming limit stress diagram (FLSD) was determined by using Hill's quadratic yield function. The results showed that the equal biaxial pre-straining decreased and shifted the FLC to the right hand side of the diagram. However, it had not any effect on the forming limit stress curves.« less
Impacting load control of floating supported friction plate and its experimental verification
NASA Astrophysics Data System (ADS)
Ning, Keyan; Wang, Yu; Huang, Dingchuan; Yin, Lei
2017-05-01
Friction plates are key components in automobile transmission system. Unfortunately, due to the tough working condition i.e. high impact, high temperature, fracture and plastic deformation are easily observed in friction plates. In order to reduce the impact load and increase the impact resistance and life span of the friction plate. This paper presents a variable damping design method and structure, by punching holes in the key position of the friction plate and filling it with damping materials, the impact load of the floating support friction plate can be controlled. Simulation is applied to study the effect of the position and number of damping holes on tooth root stress. Furthermore, physic test was designed and conducted to validate the correctness and effectiveness of the proposed method. Test result shows that the impact load of the new structure is reduced by 40% and its fatigue life is 4.7 times larger. The new structure provides a new way for floating supported friction plates design.
Use of intumescent compounds in fire curtains
NASA Astrophysics Data System (ADS)
Nedryshkin, Oleg; Gravit, Marina; Mukhamedzhanova, Olga
2017-10-01
Automatic fire curtains are designed to divide sections of premises and structures into fire compartments for the purpose of localizing a fire, as well as filling openings in fire barriers. If a fire occurs due to a signal from a fire alarm sensor or a signal from a fire station, the blind automatically falls and locates the source of ignition. The paper presents the results of testing nine samples of fire curtains with an applied intumescent composition. Tests were conducted for 60 minutes before loss of sample integrity. The average temperature from the heated side of the sample reached 800 ∼ 1000 ° C. Depending on the sample, the temperature from the unheated side ranged from 70 ° C to 294 ° C. The best result was shown by a sample from a layer of needle-punched heat-insulating material with a thermal conductivity of 0.036 W/(m×K) placed between layers of foil and treated with water-based intumescent composition of silica material.
Wound healing potential of Pterocarpus santalinus linn: a pharmacological evaluation.
Biswas, Tuhin Kanti; Maity, Lakshmi Narayan; Mukherjee, Biswapati
2004-09-01
The need for new therapeutics for wound healing has encouraged the drive to examine the nature and value of plant products. Ayurveda, the Indian traditional system of medicine, mentions the values of medicinal plants for wound healing. One of these is Pterocarpus santalinus. This article describes a pharmacological study to evaluate its toxicity as well as wound-healing potential in animal studies. Powder made from the wood of the P. santalinus tree was used to make up an ointment in a petroleum jelly base. No toxic effects were observed in 72 hours. Studies were done on punch and burn wound models on normal and diabetic rats using the test ointment, untreated and vehicle controls, and standard therapy. Physical and biochemical measurements were made. The test ointment-treated wounds healed significantly faster. On healing, collagenesis and biochemical measurements yielded supportive data. These studies permit the conclusion that the P. santalinus ointment is safe and effective in treating acute wounds in animal models.
Constraints to estimating the prevalence of trypanosome infections in East African zebu cattle.
Cox, Andrew P; Tosas, Olga; Tilley, Aimee; Picozzi, Kim; Coleman, Paul; Hide, Geoff; Welburn, Susan C
2010-09-06
In East Africa, animal trypanosomiasis is caused by many tsetse transmitted protozoan parasites including Trypanosoma vivax, T. congolense and subspecies of T. brucei s.l. (T. b. brucei and zoonotic human infective T. b. rhodesiense) that may co-circulate in domestic and wild animals. Accurate species-specific prevalence measurements of these parasites in animal populations are complicated by mixed infections of trypanosomes within individual hosts, low parasite densities and difficulties in conducting field studies. Many Polymerase Chain Reaction (PCR) based diagnostic tools are available to characterise and quantify infection in animals. These are important for assessing the contribution of infections in animal reservoirs and the risk posed to humans from zoonotic trypanosome species. New matrices for DNA capture have simplified large scale field PCR analyses but few studies have examined the impact of these techniques on prevalence estimations. The Whatman FTA matrix has been evaluated using a random sample of 35 village zebu cattle from a population naturally exposed to trypanosome infection. Using a generic trypanosome-specific PCR, prevalence was systematically evaluated. Multiple PCR samples taken from single FTA cards demonstrated that a single punch from an FTA card is not sufficient to confirm the infectivity status of an individual animal as parasite DNA is unevenly distributed across the card. At low parasite densities in the host, this stochastic sampling effect results in underestimation of prevalence based on single punch PCR testing. Repeated testing increased the estimated prevalence of all Trypanosoma spp. from 9.7% to 86%. Using repeat testing, a very high prevalence of pathogenic trypanosomes was detected in these local village cattle: T. brucei (34.3%), T. congolense (42.9%) and T. vivax (22.9%). These results show that, despite the convenience of Whatman FTA cards and specific PCR based detection tools, the chronically low parasitaemias in indigenous African zebu cattle make it difficult to establish true prevalence. Although this study specifically applies to FTA cards, a similar effect would be experienced with other approaches using blood samples containing low parasite densities. For example, using blood film microscopy or PCR detection from liquid samples where the probability of detecting a parasite or DNA molecule, in the required number of fields of view or PCR reaction, is less than one.
Constraints to estimating the prevalence of trypanosome infections in East African zebu cattle
2010-01-01
Background In East Africa, animal trypanosomiasis is caused by many tsetse transmitted protozoan parasites including Trypanosoma vivax, T. congolense and subspecies of T. brucei s.l. (T. b. brucei and zoonotic human infective T. b. rhodesiense) that may co-circulate in domestic and wild animals. Accurate species-specific prevalence measurements of these parasites in animal populations are complicated by mixed infections of trypanosomes within individual hosts, low parasite densities and difficulties in conducting field studies. Many Polymerase Chain Reaction (PCR) based diagnostic tools are available to characterise and quantify infection in animals. These are important for assessing the contribution of infections in animal reservoirs and the risk posed to humans from zoonotic trypanosome species. New matrices for DNA capture have simplified large scale field PCR analyses but few studies have examined the impact of these techniques on prevalence estimations. Results The Whatman FTA matrix has been evaluated using a random sample of 35 village zebu cattle from a population naturally exposed to trypanosome infection. Using a generic trypanosome-specific PCR, prevalence was systematically evaluated. Multiple PCR samples taken from single FTA cards demonstrated that a single punch from an FTA card is not sufficient to confirm the infectivity status of an individual animal as parasite DNA is unevenly distributed across the card. At low parasite densities in the host, this stochastic sampling effect results in underestimation of prevalence based on single punch PCR testing. Repeated testing increased the estimated prevalence of all Trypanosoma spp. from 9.7% to 86%. Using repeat testing, a very high prevalence of pathogenic trypanosomes was detected in these local village cattle: T. brucei (34.3%), T. congolense (42.9%) and T. vivax (22.9%). Conclusions These results show that, despite the convenience of Whatman FTA cards and specific PCR based detection tools, the chronically low parasitaemias in indigenous African zebu cattle make it difficult to establish true prevalence. Although this study specifically applies to FTA cards, a similar effect would be experienced with other approaches using blood samples containing low parasite densities. For example, using blood film microscopy or PCR detection from liquid samples where the probability of detecting a parasite or DNA molecule, in the required number of fields of view or PCR reaction, is less than one. PMID:20815940
Translations on Eastern Europe Scientific Affairs, Number 560
1977-10-04
Miklos Szilagyi . TAPNEG; prepares digitalized printed wiring diagram control punch tape on an ADMAP-2 graphing machine with reflection on the x axis...FOKAL 16 KE; BME, Dr Zsolt Illyefalvi-Vitez; BME, Dr Miklos Szilagyi . TESTOP-10; the program provides measurement and diagnostics for logic cards
46 CFR 164.009-3 - Noncombustible materials not requiring specific approval.
Code of Federal Regulations, 2010 CFR
2010-10-01
... subpart: (a) Sheet glass, block glass, clay, ceramics, and uncoated fibers. (b) All metals, except... only sand, gravel, expanded vermiculite, expanded or vesicular slags, diatomaceous silica, perlite, or pumice. (d) Woven, knitted or needle punched glass fabric containing no additives other than lubricants...
A system for automatic analysis of blood pressure data for digital computer entry
NASA Technical Reports Server (NTRS)
Miller, R. L.
1972-01-01
Operation of automatic blood pressure data system is described. Analog blood pressure signal is analyzed by three separate circuits, systolic, diastolic, and cycle defect. Digital computer output is displayed on teletype paper tape punch and video screen. Illustration of system is included.
Code of Federal Regulations, 2011 CFR
2011-01-01
... white paper. (ii) On paper not larger than 81/2 by 11 inches. (iii) In black ink. (iv) Text double... 1 inch on each side. (vii) The original not bound or hole-punched, only held together with removable...
Code of Federal Regulations, 2010 CFR
2010-01-01
... white paper. (ii) On paper not larger than 81/2 by 11 inches. (iii) In black ink. (iv) Text double... 1 inch on each side. (vii) The original not bound or hole-punched, only held together with removable...
Cone calorimeter evaluation of two flame retardant cotton fabrics
USDA-ARS?s Scientific Manuscript database
Unbleached (grey) cotton needle punched nonwoven (NW) fabrics with 12.5% polypropylene scrim were treated with two phosphate-nitrogen based fire-retardant (FR) formulations, SRRC-1 and SRRC-2. The SRRC-1 formulation contains diammonium phosphate as the flame retardant chemical along with urea and d...
Earth Observations taken by Expedition 26 crew
2011-03-14
ISS026-E-034079 (14 March 2011) --- From 220 miles above Japan, an Expedition 26 crew member onboard the International Space Station took this 200mm view of the Sendai coast and southward, on March 14, three days after the one-two-punch of earthquake and tsunami.
Earth Observations taken by Expedition 26 crew
2011-03-14
ISS026-E-034070 (14 March 2011) --- From 220 miles above Japan, an Expedition 26 crew member onboard the International Space Station took this 200mm view of the Sendai coast and southward, on March 14, three days after the one-two-punch of earthquake and tsunami.
Barua, Dikshita Ray; Varghese, Rana Kalappattil
2017-01-01
Introduction Denture stomatitis is an inflammatory condition which compromises the mucosal surface beneath dentures. The aetiology of denture stomatitis is usually multifactorial which varies from trauma from ill fitting denture to poor immune system. There are evidences that denture stomatitis is an outcome of multispecies biofilms that include Candida albicans and Streptococcus mutans. Tissue conditioners are found to be more susceptible to colonisation by micro-organisms. Aim The purpose of this study was to compare the efficacy of neem leaf extract and three other antimicrobial agents incorporated in a tissue conditioner against both Candida albicans and Streptococcus mutans. Materials and Methods Standard strain of Candida albicans and Streptococcus mutans were inoculated into Sabouraud Dextrose broth and Mitis-Salivarius-Bacitracin broth respectively incubated at 37°C. Tissue conditioner (Viscogel) mixed with two different concentrations of ketoconazole, nystatin and chlorhexidine diacetate (5%, 10% w/w) and neem leaf extract (7.5% w/w and 15% w/w) and control group (plain tissue conditioner) were placed into punch hole (6 mm diameter) agar plate inoculated with Candida albicans and Streptococcus mutans. A total of 216 samples were prepared for both Candida albicans and Streptococcus mutans. Mean Inhibition Diameter (MID) across each punch holes were measured in millimetres at 24 hours and seven days and data were statistically analysed using Kruskal Wallis test followed by Mann-Whitney U test. Results Both ketoconazole and nystatin (10% w/w) showed maximum inhibition of 32 mm and mean of 31.75 followed by 15% w/w neem leaf extract with an inhibition of 21 mm and mean of 20.67 after 24 hours against Candida albicans whereas chlorhexidine diacetate (10% w/w) showed mean of 25.67 followed by chlorhexidine diacetate (5% w/w) and neem extract (15% w/w) which showed mean of 24.17 and 23.67 respectively against Streptococcus mutans. Conclusion Neem leaf extract exhibited considerable potential to be an efficacious antimicrobial agent against both Candida albicans and Streptococcus mutans. PMID:28658918
ERIC Educational Resources Information Center
Scully, Maura King
2010-01-01
Increasingly today, with the growing and sophisticated skill set alumni professionals need to get the job done, alumni relations has become a destination career rather than a stop along the way. Modern alumni relations is "so much more than homecoming and punch-and-cookie receptions." It's marketing, volunteer management, and social networking. To…
A History of Computer Numerical Control.
ERIC Educational Resources Information Center
Haggen, Gilbert L.
Computer numerical control (CNC) has evolved from the first significant counting method--the abacus. Babbage had perhaps the greatest impact on the development of modern day computers with his analytical engine. Hollerith's functioning machine with punched cards was used in tabulating the 1890 U.S. Census. In order for computers to become a…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peterson, Kenneth A.; Knudson, Richard T.; Smith, Frank R.
Generally annular full tape thickness conductors are formed in single or multiple tape layers, and then stacked to produce an annular solid conductive wall for enclosing an electromagnetic isolation cavity. The conductors may be formed using punch and fill operations, or by flowing conductor-containing material onto the tape edge surfaces that define the interior sidewalls of the cavity.
Stamping Die Making. 439-318/320.
ERIC Educational Resources Information Center
Yunke, P.; And Others
Each unit in this curriculum guide on stamping die making contains an introduction, objectives, materials required, lessons, space for notes, figures, and diagrams. There are 29 units in this guide, dealing with the following topics: EZ-MILL programming; EZ-MILL BATT; print of punch and EZ-MILL part programming; download to Computer Numerical…
1981 Electronics Minisymposium Proceedings
1981-12-01
punch the hubless pole pieces out of iron sheet rolled to the required thickness and cut the spacers off custom drawn tubing. In summary, the prime...Parameters for Metal Parts. Finish of 45-50 /uin. (ground with 220 wheel ) Indium wire 0.015-in. diam. Pressures on ram of 1-in. diam. Anodes 1200 psi
ERIC Educational Resources Information Center
Hill, David
2000-01-01
Presents the story of the number one for-profit school in the United States, the Thomas A. Edison Charter Academy. Teachers had a heavier workload, but better pay and perks. Shortly after opening, many teachers were discontent with the long days and calendar, lack of follow through on promised benefits, and other issues. Reactions to this…
Programmers and Dissolve Controls for Multi-Image Presentations.
ERIC Educational Resources Information Center
Benedict, Joel A.; Fuller, Barry J.
For audiovisual personnel planning multi-image presentations, a programer is suggested and its purpose and functions explained. Digital, frequency and punched-taped programers are defined and discussed, and approximate costs given. Methods of operating are described, and the possible tie-in of a dissolve unit is discussed. Equipment hookups are…
ERIC Educational Resources Information Center
Murray, John J.
1965-01-01
Three game approaches to the teaching of poetry, designed to make the student actively involved with poems are described as "teaching tools." The semantico-dictionary or word-cross game involves programing techniques, logic, and lexicography in poetic analysis. The punched-out poem game involves filling in the blanks of a poem in which all the…
Elaboration: The Power Punch of "Body Language" Detail
ERIC Educational Resources Information Center
Berger, Joan
2003-01-01
"Zooming in" with a camera lens led students in Joan Berger's class to enrich their writing exponentially. Through class discussion of body language, along with the use of worksheets (provided), role-playing, modeling, and conferencing, one aspect of lively writing became a part of their writing repertoire. (Contains 5 figures.)
Origins of Coordinate Searching.
ERIC Educational Resources Information Center
Kilgour, Frederick G.
1997-01-01
Reviews the origins of post-coordinate searching and emphasizes that the focal point should be on the searcher, not on the item being indexed. Highlights include the history of the term information retrieval; edge notched punch cards; the "peek-a-boo" system; the Uniterm system; and using computers to search for information. (LRW)
U.S. EPA, Pesticide Product Label, PUNCH MOSQUITO REPELLENT, 12/02/1974
2011-04-21
... f'j:~O; ;&11 c: ::." N I _II . " • .. v , • 111111 ,'! • ; o "I' crill , '", : II . U: cr0ii:t:" ,,%1. X '; 't-:t- U I ~ , . III: 111::;)0< i ;J:a:mo.J I '..I: ><0< ' < : lu·.2 • " • ...
Oklahoma's Mobile Computer Graphics Laboratory.
ERIC Educational Resources Information Center
McClain, Gerald R.
This Computer Graphics Laboratory houses an IBM 1130 computer, U.C.C. plotter, printer, card reader, two key punch machines, and seminar-type classroom furniture. A "General Drafting Graphics System" (GDGS) is used, based on repetitive use of basic coordinate and plot generating commands. The system is used by 12 institutions of higher education…
Automated Sentence Completion Scoring.
ERIC Educational Resources Information Center
Veldman, Donald J.
A 62-item form of the sentence-completion technique requiring one-word responses was administered to 1718 undergraduates in teacher education. The data were punched on cards and lists of different responses were compiled. Responses indicating evasion, hostility, anxiety and depression were identified for each stem to form a scoring "dictionary." A…
Samuel Dyer and His Contributions to Chinese Typography.
ERIC Educational Resources Information Center
Ismail, Ibrahim bin
1984-01-01
This history of a London Missionary Society member's contributions to typography development in China highlights selection of 3,000 Chinese characters needed for purpose of printing Christian books, production of temporary font from wooden blocks, and use of European methods of punches and matrices to produce permanent metal font. (Twenty-seven…
Rolling with the Punches: Examining the Socialization Experiences of Kinesiology Doctoral Students
ERIC Educational Resources Information Center
Russell, Jared A.
2015-01-01
Purpose: An increasing body of literature examines the socialization experiences of graduate students on a myriad of topics across academic disciplines. However, relatively absent from these discussions are the perspectives of kinesiology doctoral students. Using Weidman, Twale, and Stein's framework for graduate and professional student…
Bullying Prevention in Middle Schools: A Collaborative Approach
ERIC Educational Resources Information Center
Studer, Jeannine R.; Mynatt, Blair S.
2015-01-01
School bullying reaches across all ages and grades, and is associated with serious mental health issues such as suicide, homicide, and other acts of violence. There are several different types of bullying that are classified as physical, verbal, relational, and cyber bullying. Physical bullying may involve hitting, punching, threatening acts, and…
5 CFR 293.107 - Special safeguards for automated records.
Code of Federal Regulations, 2014 CFR
2014-01-01
... for automated records. (a) In addition to following the security requirements of § 293.106 of this... security safeguards for data about individuals in automated records, including input and output documents, reports, punched cards, magnetic tapes, disks, and on-line computer storage. The safeguards must be in...
5 CFR 293.107 - Special safeguards for automated records.
Code of Federal Regulations, 2013 CFR
2013-01-01
... for automated records. (a) In addition to following the security requirements of § 293.106 of this... security safeguards for data about individuals in automated records, including input and output documents, reports, punched cards, magnetic tapes, disks, and on-line computer storage. The safeguards must be in...
5 CFR 293.107 - Special safeguards for automated records.
Code of Federal Regulations, 2012 CFR
2012-01-01
... for automated records. (a) In addition to following the security requirements of § 293.106 of this... security safeguards for data about individuals in automated records, including input and output documents, reports, punched cards, magnetic tapes, disks, and on-line computer storage. The safeguards must be in...
5 CFR 293.107 - Special safeguards for automated records.
Code of Federal Regulations, 2011 CFR
2011-01-01
... for automated records. (a) In addition to following the security requirements of § 293.106 of this... security safeguards for data about individuals in automated records, including input and output documents, reports, punched cards, magnetic tapes, disks, and on-line computer storage. The safeguards must be in...
ERIC Educational Resources Information Center
1972
Recent and expected developments in the computer industry are discussed in this 628-page yearbook, successor to "The Punched Card Annual." The first section of the report is an overview of current computer hardware and software and includes articles about future applications of mainframes, an analysis of the software industry, and a summary of the…
Rapid bioassay to screen potential biopesticides in Tenebrio molitor larvae
USDA-ARS?s Scientific Manuscript database
A simplified assay was devised to evaluate the response of Tenebrio molitor larvae to potential insect control products. The assay incorporates punched disks of flattened whole-grain bread placed in 96-well plates, with treatments applied topically, and neonate larvae added to each well. To evalua...
Vorreuther, R; Corleis, R; Klotz, T; Bernards, P; Engelmann, U
1995-03-01
It is known that electrohydraulic lithotripsy (EHL) during ureteroscopy may cause ureteral damage. To evaluate this trauma potential, find its mechanism and make it possible to avoid it, our research employed photographic evaluation, tissue studies, shock wave measurements and disintegration tests. The setup included a 3.3 F probe attached to an experimental generator with adjustable voltages and capacities providing energies from 25 mJ. to 1300 mJ. per pulse. In general, we distinguish between two traumatic mechanisms: (1) After placing the probe directly on the mucosa the rapid initial plasma penetrates the tissue resulting in a small, nonthermal, punched-like defect, whose depth depends on the energy applied. This trauma has minor clinical implications and is avoided by maintaining a minimum safety distance of 1 mm.; (2) According to physics, each plasma is followed by a cavitation bubble. The maximum size of this bubble depends on the energy applied and ranges from 3 mm. (25 mJ) to > 15 mm. (1300 mJ). In proportion to the bubble size, the ureteral wall may be distended or disrupted, even when the probe is not in direct contact with the mucosa. Therefore, the goal should be to obtain a low energy pressure pulse with high disintegration efficacy. Our evaluation of the pressure waves revealed that the selection of a high voltage and a low capacity leads to short and steep "laser-like" pulses. These pulses have a significant higher impact on stone disintegration than the broader pulses of the same energy provided by currently available generators.
NASA Astrophysics Data System (ADS)
Nikolov, N.; Pashkouleva, D.; Kavardzhikov, V.
2012-09-01
The paper deals with experimental investigations on the mechanical behaviour of body-centred-cubic (BCC) and face-centred-cubic (FCC)-conventionally structured sheet metalic-metalic materials under stress-strain conditions of a deep drawing process determined by a coefficient close to the limiting one for Steel 08 and punch diameter of 50 mm. The mechanical characteristics of the investigated materials are identified by one-dimensional tension tests. The materials' responses, as results of identical loading conditions, are described by the change of blank sizes and characteristics of the forming processes. The chosen deformation path ensures obtaining a qualitative steel piece and leads to failures of aluminium and brass blanks. The reported results could be useful for investigations and predictions of the mechanical responses of such type metallic structures applying microscopic instrumented observations and numerical simulations.
Numerical Taxonomy of Some Bacteria Isolated from Antarctic and Tropical Seawaters1
Pfister, Robert M.; Burkholder, Paul R.
1965-01-01
Pfister, Robert M. (Lamont Geological Observatory, Palisades, N.Y.), and Paul R. Burkholder. Numerical taxonomy of some bacteria isolated from Antarctic and tropical seawaters. J. Bacteriol. 90:863–872. 1965.—Microorganisms from Antarctic seas and from tropical waters near Puerto Rico were examined with a series of morphological, physiological, and biochemical tests. The results of these analyses were coded on punch cards, and similarity matrices were computed with a program for an IBM 1620 computer. When the matrix was reordered by use of the single-linkage technique, and the results were plotted with four symbols for different per cent similarity ranges, nine groups of microorganisms were revealed. The data suggest that organisms occurring in different areas of the open ocean may be profitably studied with standardized computer techniques. PMID:5847807
Attaching Thermocouples by Peening or Crimping
NASA Technical Reports Server (NTRS)
Murtland, Kevin; Cox, Robert; Immer, Christopher
2006-01-01
Two simple, effective techniques for attaching thermocouples to metal substrates have been devised for high-temperature applications in which attachment by such conventional means as welding, screws, epoxy, or tape would not be effective. The techniques have been used successfully to attach 0.005- in. (0.127-mm)-diameter type-S thermocouples to substrates of niobium alloy C-103 and stainless steel 416 for measuring temperatures up to 2,600 F (1,427 C). The techniques are equally applicable to other thermocouple and substrate materials. In the first technique, illustrated in the upper part of the figure, a hole slightly wider than twice the diameter of one thermocouple wire is drilled in the substrate. The thermocouple is placed in the hole, then the edge of the hole is peened in one or more places by use of a punch (see figure). The deformed material at the edge secures the thermocouple in the hole. In the second technique a hole is drilled as in the first technique, then an annular relief area is machined around the hole, resulting in structure reminiscent of a volcano in a crater. The thermocouple is placed in the hole as in the first technique, then the "volcano" material is either peened by use of a punch or crimped by use of sidecutters to secure the thermocouple in place. This second technique is preferable for very thin thermocouples [wire diameter .0.005 in. (.0.127 mm)] because standard peening poses a greater risk of clipping one or both of the thermocouple wires. These techniques offer the following advantages over prior thermocouple-attachment techniques: . Because these techniques involve drilling of very small holes, they are minimally invasive . an important advantage in that, to a first approximation, the thermal properties of surrounding areas are not appreciably affected. . These techniques do not involve introduction of any material, other than the substrate and thermocouple materials, that could cause contamination, could decompose, or oxidize at high measurement temperatures. . The simplicity of these techniques makes it possible to attach thermocouples quickly. . These techniques can be used to attach thermocouples at locations where access is somewhat restricted by the surrounding objects.
Seale, Kevin T.; Faley, Shannon L.; Chamberlain, Jeff; Wikswo, John P.
2013-01-01
Microfluidic devices are well suited for the study of metabolism and paracrine and autocrine signaling because they allow steady or intermittent perfusion of biological cells at cell densities that approach those in living tissue. They also enable the study of small populations of rare cells. However, it can be difficult to introduce the cells into a microfluidic device to achieve and control such densities without damaging or clumping the cells. We describe simple procedures that address the problem of efficient introduction of cells and cell culture media into microfluidic devices using small bore polyetheretherketone (PEEK) tubing and Hamilton gastight syringes. Suspension or adherent cells grown in cell culture flasks are centrifuged and extracted directly from the centrifuge pellet into the end of the PEEK tubing by aspiration. The tube end is then coupled to pre-punched channels in the polydimethylsiloxane (PDMS) microfluidic device by friction fitting. Controlled depression of the syringe plunger expels the cells into the microfluidic device only seconds following aspiration. The gastight syringes and PEEK tubing with PEEK fittings provide a noncompliant source of pressure and suction with a rapid response time that is well suited for short-term intra-microfluidic cellular studies. The benefits of this method are its simplicity, modest expense, the short preparation time required for loading appropriate numbers of cells, and the applicability of the technique to small quantities of rare or expensive cells. This should in turn lead to new applications of microfludic devices to biology and medicine. PMID:20511682
ERIC Educational Resources Information Center
McWilliam, Erica
2017-01-01
In this commentary, author Erica McWilliam asserts that the 2016 victory of Donald Trump in the US election is a global punch to all teachers who value pluralism and human dignity. She further maintains Trump's wild card entry into the White House directly threatens the values that teachers attempt to impart to their students--such as democracy,…
Low Tech Solutions: A Place To Begin.
ERIC Educational Resources Information Center
Ensign, Arselia S., Ed.
1992-01-01
This guide presents low tech solutions that have worked for some people with disabilities or their parents. Twenty-one ideas are offered to give children with physical disabilities more opportunities for play and art. Examples include recycling stuffed animals into puppets, punching a hole in top of playing cards to accommodate a mouth stick, and…
Proceedings of an Occupational Analysis Seminar Held at Canberra, Australia, 17-20 September 1979.
1979-09-01
stripes a man wears. NO CATEGORY EXAMPLE 48 Career Fields Medical (28 Ladders) 334 Career Ladders Pharmacy 1000+ Specialties . Pharmacist Specialist... uty /Task and Task Factor i TABLE 1, Summaries i 3. The Data Prepatory Programmes take the raw optical scanned or key punched data and: a. re-organize
Getting Started in Classroom Computing.
ERIC Educational Resources Information Center
Ahl, David H.
Written for secondary students, this booklet provides an introduction to several computer-related concepts through a set of six classroom games, most of which can be played with little more than a sheet of paper and a pencil. The games are: 1) SECRET CODES--introduction to binary coding, punched cards, and paper tape; 2) GUESS--efficient methods…
Marine Tanks: The Hard Punch of America’s Middle-Weight Fighting Force
2011-04-25
amplified by the hundreds of joyful and exuberant cheering Somali citizens. As the lifeless .figures of these American patriots were dishonored and...denounce this point as an irrational thought. If it is in fact an irrational thought, it would be a good investigative effort to identify why so many
War Termination and the Gulf War: Can We Plan Better?
2004-02-09
KTO were clearly determined to be the center-of-gravity. General Schwarzkopf stated in Senate testimony “Our military mission was to kick Iraq out of...Iraqi attention while United States Army forces maneuvered from the west with a roundhouse punch to trap and annihilate the Iraqi military in Kuwait
ERIC Educational Resources Information Center
World of Work, 1998
1998-01-01
Workplace violence has gone global, crossing borders, work settings, and occupational groups. A report from the International Labor Organization points out high-risk occupations and indicates that women are especially vulnerable. It highlights the problem and provides ways for policymakers to remove violence from the workplace. (JOW)
In Canada, Business Schools Lead Push for Globalization
ERIC Educational Resources Information Center
Lewington, Jennifer
2012-01-01
At Canadian universities, business schools are light-years ahead of the rest of the campus in raising their global profile. Intensive foreign-student-recruitment efforts, friendly Canadian immigration rules, mandatory study-abroad requirements, and, in some cases, the option to pursue programs in multiple languages have combined to pack a punch in…
Delineating Grazing: Observations of Remote Control Use.
ERIC Educational Resources Information Center
Eastman, Susan Tyler; Newton, Gregory D.
1995-01-01
States that contrary to previous reports of "grazing," most viewers only used their remote control devices (RCDs) once or twice every half hour. Claims that the dominant RCD operation was direct channel punching, as opposed to dial turning. Concludes that most RCD activity did not take place during a program, thus voiding industry…
A method for polycrystalline silicon delineation applicable to a double-diffused MOS transistor
NASA Technical Reports Server (NTRS)
Halsor, J. L.; Lin, H. C.
1974-01-01
Method is simple and eliminates requirement for unreliable special etchants. Structure is graded in resistivity to prevent punch-through and has very narrow channel length to increase frequency response. Contacts are on top to permit planar integrated circuit structure. Polycrystalline shield will prevent creation of inversion layer in isolated region.
Yukon River King Salmon - Ichthyophonus Pilot Study
Kocan, R.M.; Hershberger, P.K.
2001-01-01
A method for non-lethal sampling of adult spawning Chinook salmon for Ichthyophonus was developed using known infected fish and live returning spawners. The method consisted of taking punch biopsies of skin and muscle and culturing the biopsy tissue in vitro. A 100% correlation was made between known infected fish and cultured biopsy tissue.
English Revisited: Sucker Punch, Moffatt, Avatars and Forensic Evidence
ERIC Educational Resources Information Center
Russell, Jennifer; Beavis, Catherine
2012-01-01
Contemporary curriculum guidelines, such as those provided in the incoming Australian curriculum, call for English to attend to multimodal forms of text and literacy as well as more traditional forms. Students are expected to become capable and critical readers, users and creators of texts and forms of literacy that span everything from newspapers…
46 CFR 44.05-35 - Form of load line certificate.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) Below (S). *Allowance for fresh water for all freeboards (except on the Great Lakes) *Where seagoing steamers navigate a river or inland water, deeper loading is permitted corresponding to the weight of fuel... Regulations, the disk or diamond and the lines must be permanently marked by center punch marks or cutting. (2...
ERIC Educational Resources Information Center
Demski, Jennifer
2008-01-01
A student committee whose main duty is changing light bulbs may sound like the punch line to a bad joke, but as the students and faculty at Montgomery County Public Schools (MCPS) in Rockville, MD, know, changing a light bulb is no laughing matter. As part of the district's green initiative, all standard incandescent and fluorescent light bulbs…
ERIC Educational Resources Information Center
Schaffhauser, Dian
2011-01-01
A freak blizzard, a mentally ill and armed student, a record-breaking flood. No matter how idyllic a campus may feel, no matter how cocooned the ivory tower, disaster can strike. If a campus is unprepared, it comes like a sucker punch, potentially turning a crisis into a tragedy of unimagined proportions--and causing reverberations that will be…
49 CFR 821.7 - Filing of documents with the Board.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., National Transportation Safety Board, 490 L'Enfant Plaza East SW., Washington, DC 20594, and addressed to... filed with the Office of General Counsel, National Transportation Safety Board, 490 L'Enfant Plaza East... upper left-hand corner by staple or clip, and shall not be bound or hole-punched. Any document failing...
Age-related emotional bias in processing two emotionally valenced tasks.
Allen, Philip A; Lien, Mei-Ching; Jardin, Elliott
2017-01-01
Previous studies suggest that older adults process positive emotions more efficiently than negative emotions, whereas younger adults show the reverse effect. We examined whether this age-related difference in emotional bias still occurs when attention is engaged in two emotional tasks. We used a psychological refractory period paradigm and varied the emotional valence of Task 1 and Task 2. In both experiments, Task 1 was emotional face discrimination (happy vs. angry faces) and Task 2 was sound discrimination (laugh, punch, vs. cork pop in Experiment 1 and laugh vs. scream in Experiment 2). The backward emotional correspondence effect for positively and negatively valenced Task 2 on Task 1 was measured. In both experiments, younger adults showed a backward correspondence effect from a negatively valenced Task 2, suggesting parallel processing of negatively valenced stimuli. Older adults showed similar negativity bias in Experiment 2 with a more salient negative sound ("scream" relative to "punch"). These results are consistent with an arousal-bias competition model [Mather and Sutherland (Perspectives in Psychological Sciences 6:114-133, 2011)], suggesting that emotional arousal modulates top-down attentional control settings (emotional regulation) with age.
McGrane, J; Carswell, S; Talbot, T
2017-01-01
We report a case of a 66-year-old man with locally advanced and metastatic basal cell carcinoma (BCC) causing spinal cord compression, which was treated with spinal surgery and subsequent vismodegib. The patient presented with a large fungating chest wall lesion and a metastasis in T8 that was causing cord compression. He had neurosurgical decompression of the T8 lesion and fixation of the spine. Punch biopsy from the fungating chest wall lesion showed a BCC with some malignant squamous differentiation (basosquamous). Histopathological examination of the metastatic lesion in T8 at the time of surgical decompression identified features identical to the punch biopsy. The patient was referred to the oncology clinic for adjuvant treatment. In light of his metastatic disease and the large area over his chest wall that could not fully be covered by radiotherapy, he was treated with the novel oral Hedgehog signalling pathway (HHSP) inhibitor vismodegib, which led to marked improvement. © 2016 British Association of Dermatologists.