Sample records for small volume human

  1. Mechanistic Fluid Transport Model to Estimate Gastrointestinal Fluid Volume and Its Dynamic Change Over Time.

    PubMed

    Yu, Alex; Jackson, Trachette; Tsume, Yasuhiro; Koenigsknecht, Mark; Wysocki, Jeffrey; Marciani, Luca; Amidon, Gordon L; Frances, Ann; Baker, Jason R; Hasler, William; Wen, Bo; Pai, Amit; Sun, Duxin

    2017-11-01

    Gastrointestinal (GI) fluid volume and its dynamic change are integral to study drug disintegration, dissolution, transit, and absorption. However, key questions regarding the local volume and its absorption, secretion, and transit remain unanswered. The dynamic fluid compartment absorption and transit (DFCAT) model is proposed to estimate in vivo GI volume and GI fluid transport based on magnetic resonance imaging (MRI) quantified fluid volume. The model was validated using GI local concentration of phenol red in human GI tract, which was directly measured by human GI intubation study after oral dosing of non-absorbable phenol red. The measured local GI concentration of phenol red ranged from 0.05 to 168 μg/mL (stomach), to 563 μg/mL (duodenum), to 202 μg/mL (proximal jejunum), and to 478 μg/mL (distal jejunum). The DFCAT model characterized observed MRI fluid volume and its dynamic changes from 275 to 46.5 mL in stomach (from 0 to 30 min) with mucus layer volume of 40 mL. The volumes of the 30 small intestine compartments were characterized by a max of 14.98 mL to a min of 0.26 mL (0-120 min) and a mucus layer volume of 5 mL per compartment. Regional fluid volumes over 0 to 120 min ranged from 5.6 to 20.38 mL in the proximal small intestine, 36.4 to 44.08 mL in distal small intestine, and from 42 to 64.46 mL in total small intestine. The DFCAT model can be applied to predict drug dissolution and absorption in the human GI tract with future improvements.

  2. A Modular Habitation System for Human Planetary and Space Exploration

    NASA Technical Reports Server (NTRS)

    Howe, A. Scott

    2015-01-01

    A small-diameter modular pressure vessel system is devised that can be applied to planetary surface and deep space human exploration missions. As one of the recommendations prepared for the NASA Human Spaceflight Architecture Team (HAT) Evolvable Mars Campaign (EMC), a compact modular system can provide a Mars-forward approach to a variety of missions and environments. Small cabins derived from the system can fit into the Space Launch System (SLS) Orion "trunk", or can be mounted with mobility systems to function as pressurized rovers, in-space taxis, ascent stage cabins, or propellant tanks. Larger volumes can be created using inflatable elements for long-duration deep space missions and planetary surface outposts. This paper discusses how a small-diameter modular system can address functional requirements, mass and volume constraints, and operational scenarios.

  3. Measurement of Human Blood and Plasma Volumes

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Szalkay, H. G. H.

    1987-01-01

    Report reviews techniques for measuring blood-plasma volume in humans. Common technique of using radioactive iodine isotope to label plasma albumin involves unwarranted risks from low-level radiation. Report emphasizes techniques using Evans-blue-dye (T-1824) labeling of albumin, hematocrit or hemoglobin/hematocrit measurements, or blood densitometry. In Evans-blue-dye technique, plasma volume determined from decrease in dye concentration occurring after small amount of dye solution injected into circulatory system. Subjection of Evans blue dye to test for carcinogenicity gave negative results.

  4. Recent Human Factors Contributions to Improve Military Operations (Human Factors and Ergonomics Society Bulletin. Volume 46, Number 12, December 2003)

    DTIC Science & Technology

    2003-12-01

    operations run the full gamut from large-scale, theater-wide combat, as witnessed in Operation Iraqi Freedom, to small-scale operations against terrorists, to... gamut from large-scale, theater-wide combat, as witnessed in Operation Iraqi Freedom, to small-scale operations against terror- ists, to operations

  5. [Pulmonary cystic disease may be a rare complication to recurrent respiratory human papilloma virus infection].

    PubMed

    Laurberg, Peter Thaysen; Weinreich, Ulla M Øller

    2014-12-08

    A 19-year-old woman with a history of juvenile laryngeal papillomatosis (JLP), treated since childhood with multiple resections, was admitted with symptoms of pneumonia. A chest X-ray and CAT-scan revealed multiple lung cysts and a bronchoalveolar lavage detected human papilloma virus 11. The patient responded well to antibiotics. A body plethysmography showed small lung volumes and low diffusion capacity for carbon monoxide, but normal volume diffusion capacity divided by alveolar volume. Pulmonary cystic disease should be considered when patients with JLP have symptoms of pneumonia.

  6. Strategies for Small Volume Resuscitation: Hyperosmotic-Hyperoncotic Solutions, Hemoglobin Based Oxygen Carriers and Closed-Loop Resuscitation

    NASA Technical Reports Server (NTRS)

    Kramer, George C.; Wade, Charles E.; Dubick, Michael A.; Atkins, James L.

    2004-01-01

    Introduction: Logistic constraints on combat casualty care preclude traditional resuscitation strategies which can require volumes and weights 3 fold or greater than hemorrhaged volume. We present a review of quantitative analyses of clinical and animal data on small volume strategies using 1) hypertonic-hyperosmotic solutions (HHS); 2) hemoglobin based oxygen carriers (HBOCs) and 3) closed-loop infusion regimens.Methods and Results: Literature searches and recent queries to industry and academic researchers have allowed us to evaluate the record of 81 human HHS studies (12 trauma trials), 19 human HBOCs studies (3trauma trials) and two clinical studies of closed-loop resuscitation.There are several hundreds animal studies and at least 82 clinical trials and reports evaluating small volume7.2%-7.5% hypertonic saline (HS) most often combined with colloids, e.g., dextran (HSD) or hetastarch(HSS). HSD and HSS data has been published for 1,108 and 392 patients, respectively. Human studies have documented volume sparing and hemodynamic improvements. Meta-analyses suggest improved survival for hypotensive trauma patients treated with HSD with significant reductions in mortality found for patients with blood pressure < 70 mmHg, head trauma, and penetrating injury requiring surgery. HSD and HSS have received regulatory approval in 14 and 3 countries, respectively, with 81,000+ units sold. The primary reported use was head injury and trauma resuscitation. Complications and reported adverse events are surprisingly rare and not significantly different from other solutions.HBOCs are potent volume expanders in addition to oxygen carriers with volume expansion greater than standard colloids. Several investigators have evaluated small volume hyperoncotic HBOCs or HS-HBOC formulations for hypotensive and normotensive resuscitation in animals. A consistent finding in resuscitation with HBOCs is depressed cardiac output. There is some evidence that HBOCs more efficiently unload oxygen from plasma hemoglobin as well as facilitate RBC unloading. We analyzed one volunteer study, 15 intraoperative trials, and 3 trauma studies using HBOCs. Perioperative studies generally suggest ability to deliver oxygen, but one trauma trial using HBOCs (HemAssist) for treatment of trauma resulted in a dramatic increase in mortality, while an intraoperative trauma study using Polyheme demonstrated reductions in blood use and lower mortality compared to historic controls of patients refusing blood. Transfusion reductions with HBOC use have been modest. Two HBOCs (Hemopure and Polyheme) are now in new or planned large-scale multicenter prehospital trials of trauma treatment. A new implementation of small volume resuscitation is closed-loop resuscitation (CLR), which employs microprocessors to titrate just enough fluid to reach a physiologic target . Animal studies suggest less risk of rebleeding in uncontrolled hemorrhage and a reduction in fluid needs with CLR. The first clinical application of CLR was treatment of burn shock and the US Army. Conclusions: Independently sponsored civilian trauma trials and clinical evaluations in operational combat conditions of different small volume strategies are warranted.

  7. Manpower Advisory Services in the Workplace: A Missing Link in National Manpower Policy. Volume I.

    ERIC Educational Resources Information Center

    Hansen, Gary B.; Bentley, Marion T.

    This first volume of a two-volume final report contains description and findings of a 3-year research and demonstration project in which a small human resource diagnostic and consulting service was established at a State land-grant institution (Utah State University) to provide a broadly based technical assistance program directed toward improving…

  8. SU-G-IeP4-11: Monitoring Tumor Growth in Subcutaneous Murine Tumor Model in Vivo: A Comparison Between MRI and Small Animal CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, B; He, W; Cvetkovic, D

    Purpose: The purpose of the study is to compare the volume measurement of subcutaneous tumors in mice with different imaging platforms, namely a GE MRI and a Sofie-Biosciences small animal CT scanner. Methods: A549 human lung carcinoma cells and FaDu human head and neck squamous cell carcinoma cells were implanted subcutaneously into flanks of nude mice. Three FaDu tumors and three A549 tumors were included in this study. The MRI scans were done with a GE Signa 1.5 Tesla MR scanner using a fast T2-weighted sequence (70mm FOV and 1.2mm slice thickness), while the CT scans were done with themore » CT scanner on a Sofie-Biosciences G8 PET/CT platform dedicated for small animal studies (48mm FOV and 0.2mm slice thickness). Imaging contrast agent was not used in this study. Based on the DICOM images from MRI and CT scans, the tumors were contoured with Philips DICOM Viewer and the tumor volumes were obtained by summing up the contoured area and multiplied by the slice thickness. Results: The volume measurements based on the CT scans agree reasonably with that obtained with MR images for the subcutaneous tumors. The mean difference in the absolute tumor volumes between MRI- and CT-based measurements was found to be −6.2% ± 1.0%, with the difference defined as (VMR – VCT)*100%/VMR. Furthermore, we evaluated the normalized tumor volumes, which were defined for each tumor as V/V{sub 0} where V{sub 0} stands for the volume from the first MR or CT scan. The mean difference in the normalized tumor volumes was found to be 0.10% ± 0.96%. Conclusion: Despite the fact that the difference between normal and abnormal tissues is often less clear on small animal CT images than on MR images, one can still obtain reasonable tumor volume information with the small animal CT scans for subcutaneous murine xenograft models.« less

  9. Minding your Own Small Business - An Introductory Curriculum for Small Business Management. Volume I.

    ERIC Educational Resources Information Center

    Holt, Nancy; And Others

    Ten units on the basic knowledge and skills needed to manage a small business are provided in this curriculum guide designed for use with secondary and postsecondary students. Unit topics include forms of businesses, marketing, location, systems and records, promotion, pricing, human relations, financing a business, and effects of business…

  10. Three-dimensional microscopic tomographic imagings of the cataract in a human lens in vivo

    NASA Astrophysics Data System (ADS)

    Masters, Barry R.

    1998-10-01

    The problem of three-dimensional visualization of a human lens in vivo has been solved by a technique of volume rendering a transformed series of 60 rotated Scheimpflug (a dual slit reflected light microscope) digital images. The data set was obtained by rotating the Scheimpflug camera about the optic axis of the lens in 3 degree increments. The transformed set of optical sections were first aligned to correct for small eye movements, and then rendered into a volume reconstruction with volume rendering computer graphics techniques. To help visualize the distribution of lens opacities (cataracts) in the living, human lens the intensity of light scattering was pseudocolor coded and the cataract opacities were displayed as a movie.

  11. Quantification of gastrointestinal liquid volumes and distribution following a 240 mL dose of water in the fasted state.

    PubMed

    Mudie, Deanna M; Murray, Kathryn; Hoad, Caroline L; Pritchard, Susan E; Garnett, Martin C; Amidon, Gordon L; Gowland, Penny A; Spiller, Robin C; Amidon, Gregory E; Marciani, Luca

    2014-09-02

    The rate and extent of drug dissolution and absorption from solid oral dosage forms is highly dependent upon the volumes and distribution of gastric and small intestinal water. However, little is known about the time courses and distribution of water volumes in vivo in an undisturbed gut. Previous imaging studies offered a snapshot of water distribution in fasted humans and showed that water in the small intestine is distributed in small pockets. This study aimed to quantify the volume and number of water pockets in the upper gut of fasted healthy humans following ingestion of a glass of water (240 mL, as recommended for bioavailability/bioequivalence (BA/BE) studies), using recently validated noninvasive magnetic resonance imaging (MRI) methods. Twelve healthy volunteers underwent upper and lower abdominal MRI scans before drinking 240 mL (8 fluid ounces) of water. After ingesting the water, they were scanned at intervals for 2 h. The drink volume, inclusion criteria, and fasting conditions matched the international standards for BA/BE testing in healthy volunteers. The images were processed for gastric and intestinal total water volumes and for the number and volume of separate intestinal water pockets larger than 0.5 mL. The fasted stomach contained 35 ± 7 mL (mean ± SEM) of resting water. Upon drinking, the gastric fluid rose to 242 ± 9 mL. The gastric water volume declined rapidly after that with a half emptying time (T50%) of 13 ± 1 min. The mean gastric volume returned back to baseline 45 min after the drink. The fasted small bowel contained a total volume of 43 ± 14 mL of resting water. Twelve minutes after ingestion of water, small bowel water content rose to a maximum value of 94 ± 24 mL contained within 15 ± 2 pockets of 6 ± 2 mL each. At 45 min, when the glass of water had emptied completely from the stomach, total intestinal water volume was 77 ± 15 mL distributed into 16 ± 3 pockets of 5 ± 1 mL each. MRI provided unprecedented insights into the time course, number, volume, and location of water pockets in the stomach and small intestine under conditions that represent standard BA/BE studies using validated techniques. These data add to our current understanding of gastrointestinal physiology and will help improve physiological relevance of in vitro testing methods and in silico transport analyses for prediction of bioperformance of oral solid dosage forms, particularly for low solubility Biopharmaceutics Classification System (BCS) Class 2 and Class 4 compounds.

  12. Small-volume resuscitation from hemorrhagic shock with polymerized human serum albumin.

    PubMed

    Messmer, Catalina; Yalcin, Ozlem; Palmer, Andre F; Cabrales, Pedro

    2012-10-01

    Human serum albumin (HSA) is used as a plasma expander; however, albumin is readily eliminated from the intravascular space. The objective of this study was to establish the effects of various-sized polymerized HSAs (PolyHSAs) during small-volume resuscitation from hemorrhagic shock on systemic parameters, microvascular hemodynamics, and functional capillary density in the hamster window chamber model. Polymerized HSA size was controlled by varying the cross-link density (ie, molar ratio of glutaraldehyde to HSA). Hemorrhage was induced by controlled arterial bleeding of 50% of the animal's blood volume (BV), and hypovolemic shock was maintained for 1 hour. Resuscitation was implemented in 2 phases, first, by infusion of 3.5% of the BV of hypertonic saline (7.5% NaCl) then followed by infusion of 10% of the BV of each PolyHSA. Resuscitation provided rapid recovery of blood pressure, blood gas parameters, and microvascular perfusion. Polymerized HSA at a glutaraldehyde-to-HSA molar ratio of 60:1 (PolyHSA(60:1)) provided superior recovery of blood pressure, microvascular blood flow, and functional capillary density, and acid-base balance, with sustained volume expansion in relation to the volume infused. The high molecular weight of PolyHSA(60:1) increased the hydrodynamic radius and solution viscosity. Pharmacokinetic analysis of PolyHSA(60:1) indicates reduced clearance and increased circulatory half-life compared with monomeric HSA and other PolyHSA formulations. In conclusion, HSA molecular size and solution viscosity affect central hemodynamics, microvascular blood flow, volume expansion, and circulation persistence during small-volume resuscitation from hemorrhagic shock. In addition, PolyHSA can be an alternative to HSA in pathophysiological situations with compromised vascular permeability. Copyright © 2012 Elsevier Inc. All rights reserved.

  13. Effect of a selective chloride channel activator, lubiprostone, on gastrointestinal transit, gastric sensory, and motor functions in healthy volunteers.

    PubMed

    Camilleri, Michael; Bharucha, Adil E; Ueno, Ryuji; Burton, Duane; Thomforde, George M; Baxter, Kari; McKinzie, Sanna; Zinsmeister, Alan R

    2006-05-01

    Chloride channels modulate gastrointestinal neuromuscular functions in vitro. Lubiprostone, a selective type 2 chloride channel (ClC-2) activator, induces intestinal secretion and has been shown to relieve constipation in clinical trials; however, the effects of lubiprostone on gastric function and whole gut transit in humans are unclear. Our aim was to compare the effects of the selective ClC-2 activator lubiprostone on maximum tolerated volume (MTV) of a meal, postprandial symptoms, gastric volumes, and gastrointestinal and colonic transit in humans. We performed a randomized, parallel-group, double-blind, placebo-controlled study evaluating the effects of lubiprostone (24 microg bid) in 30 healthy volunteers. Validated methods were used: scintigraphic gastrointestinal and colonic transit, SPECT to measure gastric volumes, and the nutrient drink ("satiation") test to measure MTV and postprandial symptoms. Lubiprostone accelerated small bowel and colonic transit, increased fasting gastric volume, and retarded gastric emptying. MTV values were reduced compared with placebo; however, the MTV was within the normal range for healthy adults in 13 of 14 participants, and there was no significant change compared with baseline measurements. Lubiprostone had no significant effect on postprandial gastric volume or aggregate symptoms but did decrease fullness 30 min after the fully satiating meal. Thus the ClC-2 activator lubiprostone accelerates small intestinal and colonic transit, which confers potential in the treatment of constipation.

  14. Analysis of the volumetric relationship among human ocular, orbital and fronto-occipital cortical morphology

    PubMed Central

    Masters, Michael; Bruner, Emiliano; Queer, Sarah; Traynor, Sarah; Senjem, Jess

    2015-01-01

    Recent research on the visual system has focused on investigating the relationship among eye (ocular), orbital, and visual cortical anatomy in humans. This issue is relevant in evolutionary and medical fields. In terms of evolution, only in modern humans and Neandertals are the orbits positioned beneath the frontal lobes, with consequent structural constraints. In terms of medicine, such constraints can be associated with minor deformation of the eye, vision defects, and patterns of integration among these features, and in association with the frontal lobes, are important to consider in reconstructive surgery. Further study is therefore necessary to establish how these variables are related, and to what extent ocular size is associated with orbital and cerebral cortical volumes. Relationships among these anatomical components were investigated using magnetic resonance images from a large sample of 83 individuals, which also included each subject’s body height, age, sex, and uncorrected visual acuity score. Occipital and frontal gyri volumes were calculated using two different cortical parcellation tools in order to provide a better understanding of how the eye and orbit vary in relation to visual cortical gyri, and frontal cortical gyri which are not directly related to visual processing. Results indicated that ocular and orbital volumes were weakly correlated, and that eye volume explains only a small proportion of the variance in orbital volume. Ocular and orbital volumes were also found to be equally and, in most cases, more highly correlated with five frontal lobe gyri than with occipital lobe gyri associated with V1, V2, and V3 of the visual cortex. Additionally, after accounting for age and sex variation, the relationship between ocular and total visual cortical volume was no longer statistically significant, but remained significantly related to total frontal lobe volume. The relationship between orbital and visual cortical volumes remained significant for a number of occipital lobe gyri even after accounting for these cofactors, but was again found to be more highly correlated with the frontal cortex than with the occipital cortex. These results indicate that eye volume explains only a small amount of variation in orbital and visual cortical volume, and that the eye and orbit are generally more structurally associated with the frontal lobes than they are functionally associated with the visual cortex of the occipital lobes. Results also demonstrate that these components of the visual system are highly complex and influenced by a multitude of factors in humans. PMID:26250048

  15. Novel methods of treating ovarian infertility in older and POF women, testicular infertility, and other human functional diseases.

    PubMed

    Bukovsky, Antonin

    2015-02-25

    In vitro maturation (IVM) and in vitro fertilization (IVF) technologies are facing with growing demands of older women to conceive. Although ovarian stem cells (OSCs) of older women are capable of producing in vitro fresh oocyte-like cells (OLCs), such cells cannot respond to IVM and IVF due to the lack of granulosa cells required for their maturation. Follicular renewal is also dependent on support of circulating blood mononuclear cells. They induce intermediary stages of meiosis (metaphase I chromosomal duplication and crossover, anaphase, telophase, and cytokinesis) in newly emerging ovarian germ cells, as for the first time demonstrated here, induce formation of granulosa cells, and stimulate follicular growth and development. A pretreatment of OSC culture with mononuclear cells collected from blood of a young healthy fertile woman may cause differentiation of bipotential OSCs into both developing germ and granulosa cells. A small blood volume replacement may enable treatment of ovarian infertility in vivo. The transferred mononuclear cells may temporarily rejuvenate virtually all tissues, including improvement of the function of endocrine tissues. Formation of new follicles and their development may be sufficient for IVM and IVF. The novel proposed in vitro approaches may be used as a second possibility. Infertility of human males affects almost a half of the infertility cases worldwide. Small blood volume replacement from young healthy fertile men may also be easy approach for the improvement of sperm quality in older or other affected men. In addition, body rejuvenation by small blood volume replacement from young healthy individuals of the same sex could represent a decline of in vitro methodology in favor of in vivo treatment for human functional diseases. Here we propose for the first time that blood mononuclear cells are essential for rejuvenation of those tissues, where immune system components participate in an appropriate division and differentiation of tissue stem cells. If needed, small blood volume replacement from distinct young healthy individuals could be utilized in six month intervals for repair of young altered or aged reproductive and other tissue functions. Systemic and local use of honey bee propolis tincture is an alternative option for functional rejuvenation of some tissues.

  16. In vivo detection of small tumour lesions by multi-pinhole SPECT applying a 99mTc-labelled nanobody targeting the Epidermal Growth Factor Receptor

    PubMed Central

    Krüwel, Thomas; Nevoltris, Damien; Bode, Julia; Dullin, Christian; Baty, Daniel; Chames, Patrick; Alves, Frauke

    2016-01-01

    The detection of tumours in an early phase of tumour development in combination with the knowledge of expression of tumour markers such as epidermal growth factor receptor (EGFR) is an important prerequisite for clinical decisions. In this study we applied the anti-EGFR nanobody 99mTc-D10 for visualizing small tumour lesions with volumes below 100 mm3 by targeting EGFR in orthotopic human mammary MDA-MB-468 and MDA-MB-231 and subcutaneous human epidermoid A431 carcinoma mouse models. Use of nanobody 99mTc-D10 of a size as small as 15.5 kDa enables detection of tumours by single photon emission computed tomography (SPECT) imaging already 45 min post intravenous administration with high tumour uptake (>3% ID/g) in small MDA-MB-468 and A431 tumours, with tumour volumes of 52.5 mm3 ± 21.2 and 26.6 mm3 ± 16.7, respectively. Fast blood clearance with a serum half-life of 4.9 min resulted in high in vivo contrast and ex vivo tumour to blood and tissue ratios. In contrast, no accumulation of 99mTc-D10 in MDA-MB-231 tumours characterized by a very low expression of EGFR was observed. Here we present specific and high contrast in vivo visualization of small human tumours overexpressing EGFR by preclinical multi-pinhole SPECT shortly after administration of anti-EGFR nanobody 99mTc-D10. PMID:26912069

  17. Identification of common variants associated with human hippocampal and intracranial volumes.

    PubMed

    Stein, Jason L; Medland, Sarah E; Vasquez, Alejandro Arias; Hibar, Derrek P; Senstad, Rudy E; Winkler, Anderson M; Toro, Roberto; Appel, Katja; Bartecek, Richard; Bergmann, Ørjan; Bernard, Manon; Brown, Andrew A; Cannon, Dara M; Chakravarty, M Mallar; Christoforou, Andrea; Domin, Martin; Grimm, Oliver; Hollinshead, Marisa; Holmes, Avram J; Homuth, Georg; Hottenga, Jouke-Jan; Langan, Camilla; Lopez, Lorna M; Hansell, Narelle K; Hwang, Kristy S; Kim, Sungeun; Laje, Gonzalo; Lee, Phil H; Liu, Xinmin; Loth, Eva; Lourdusamy, Anbarasu; Mattingsdal, Morten; Mohnke, Sebastian; Maniega, Susana Muñoz; Nho, Kwangsik; Nugent, Allison C; O'Brien, Carol; Papmeyer, Martina; Pütz, Benno; Ramasamy, Adaikalavan; Rasmussen, Jerod; Rijpkema, Mark; Risacher, Shannon L; Roddey, J Cooper; Rose, Emma J; Ryten, Mina; Shen, Li; Sprooten, Emma; Strengman, Eric; Teumer, Alexander; Trabzuni, Daniah; Turner, Jessica; van Eijk, Kristel; van Erp, Theo G M; van Tol, Marie-Jose; Wittfeld, Katharina; Wolf, Christiane; Woudstra, Saskia; Aleman, Andre; Alhusaini, Saud; Almasy, Laura; Binder, Elisabeth B; Brohawn, David G; Cantor, Rita M; Carless, Melanie A; Corvin, Aiden; Czisch, Michael; Curran, Joanne E; Davies, Gail; de Almeida, Marcio A A; Delanty, Norman; Depondt, Chantal; Duggirala, Ravi; Dyer, Thomas D; Erk, Susanne; Fagerness, Jesen; Fox, Peter T; Freimer, Nelson B; Gill, Michael; Göring, Harald H H; Hagler, Donald J; Hoehn, David; Holsboer, Florian; Hoogman, Martine; Hosten, Norbert; Jahanshad, Neda; Johnson, Matthew P; Kasperaviciute, Dalia; Kent, Jack W; Kochunov, Peter; Lancaster, Jack L; Lawrie, Stephen M; Liewald, David C; Mandl, René; Matarin, Mar; Mattheisen, Manuel; Meisenzahl, Eva; Melle, Ingrid; Moses, Eric K; Mühleisen, Thomas W; Nauck, Matthias; Nöthen, Markus M; Olvera, Rene L; Pandolfo, Massimo; Pike, G Bruce; Puls, Ralf; Reinvang, Ivar; Rentería, Miguel E; Rietschel, Marcella; Roffman, Joshua L; Royle, Natalie A; Rujescu, Dan; Savitz, Jonathan; Schnack, Hugo G; Schnell, Knut; Seiferth, Nina; Smith, Colin; Steen, Vidar M; Valdés Hernández, Maria C; Van den Heuvel, Martijn; van der Wee, Nic J; Van Haren, Neeltje E M; Veltman, Joris A; Völzke, Henry; Walker, Robert; Westlye, Lars T; Whelan, Christopher D; Agartz, Ingrid; Boomsma, Dorret I; Cavalleri, Gianpiero L; Dale, Anders M; Djurovic, Srdjan; Drevets, Wayne C; Hagoort, Peter; Hall, Jeremy; Heinz, Andreas; Jack, Clifford R; Foroud, Tatiana M; Le Hellard, Stephanie; Macciardi, Fabio; Montgomery, Grant W; Poline, Jean Baptiste; Porteous, David J; Sisodiya, Sanjay M; Starr, John M; Sussmann, Jessika; Toga, Arthur W; Veltman, Dick J; Walter, Henrik; Weiner, Michael W; Bis, Joshua C; Ikram, M Arfan; Smith, Albert V; Gudnason, Vilmundur; Tzourio, Christophe; Vernooij, Meike W; Launer, Lenore J; DeCarli, Charles; Seshadri, Sudha; Andreassen, Ole A; Apostolova, Liana G; Bastin, Mark E; Blangero, John; Brunner, Han G; Buckner, Randy L; Cichon, Sven; Coppola, Giovanni; de Zubicaray, Greig I; Deary, Ian J; Donohoe, Gary; de Geus, Eco J C; Espeseth, Thomas; Fernández, Guillén; Glahn, David C; Grabe, Hans J; Hardy, John; Hulshoff Pol, Hilleke E; Jenkinson, Mark; Kahn, René S; McDonald, Colm; McIntosh, Andrew M; McMahon, Francis J; McMahon, Katie L; Meyer-Lindenberg, Andreas; Morris, Derek W; Müller-Myhsok, Bertram; Nichols, Thomas E; Ophoff, Roel A; Paus, Tomas; Pausova, Zdenka; Penninx, Brenda W; Potkin, Steven G; Sämann, Philipp G; Saykin, Andrew J; Schumann, Gunter; Smoller, Jordan W; Wardlaw, Joanna M; Weale, Michael E; Martin, Nicholas G; Franke, Barbara; Wright, Margaret J; Thompson, Paul M

    2012-04-15

    Identifying genetic variants influencing human brain structures may reveal new biological mechanisms underlying cognition and neuropsychiatric illness. The volume of the hippocampus is a biomarker of incipient Alzheimer's disease and is reduced in schizophrenia, major depression and mesial temporal lobe epilepsy. Whereas many brain imaging phenotypes are highly heritable, identifying and replicating genetic influences has been difficult, as small effects and the high costs of magnetic resonance imaging (MRI) have led to underpowered studies. Here we report genome-wide association meta-analyses and replication for mean bilateral hippocampal, total brain and intracranial volumes from a large multinational consortium. The intergenic variant rs7294919 was associated with hippocampal volume (12q24.22; N = 21,151; P = 6.70 × 10(-16)) and the expression levels of the positional candidate gene TESC in brain tissue. Additionally, rs10784502, located within HMGA2, was associated with intracranial volume (12q14.3; N = 15,782; P = 1.12 × 10(-12)). We also identified a suggestive association with total brain volume at rs10494373 within DDR2 (1q23.3; N = 6,500; P = 5.81 × 10(-7)).

  18. Bismuth-Based, Disposable Sensor for the Detection of Hydrogen Sulfide Gas.

    PubMed

    Rosolina, Samuel M; Carpenter, Thomas S; Xue, Zi-Ling

    2016-02-02

    A new sensor for the detection of hydrogen sulfide (H2S) gas has been developed to replace commercial lead(II) acetate-based test papers. The new sensor is a wet, porous, paper-like substrate coated with Bi(OH)3 or its alkaline derivatives at pH 11. In contrast to the neurotoxic lead(II) acetate, bismuth is used due to its nontoxic properties, as Bi(III) has been a reagent in medications such as Pepto-Bismol. The reaction between H2S gas and the current sensor produces a visible color change from white to yellow/brown, and the sensor responds to ≥ 30 ppb H2S in a total volume of 1.35 L of gas, a typical volume of human breath. The alkaline, wet coating helps the trapping of acidic H2S gas and its reaction with Bi(III) species, forming colored Bi2S3. The sensor is suitable for testing human bad breath and is at least 2 orders of magnitude more sensitive than a commercial H2S test paper based on Pb(II)(acetate)2. The small volume of 1.35-L H2S is important, as the commercial Pb(II)(acetate)2-based paper requires large volumes of 5 ppm H2S gas. The new sensor reported here is inexpensive, disposable, safe, and user-friendly. A simple, laboratory setup for generating small volumes of ppb-ppm of H2S gas is also reported.

  19. 3D ultrasound volume stitching using phase symmetry and harris corner detection for orthopaedic applications

    NASA Astrophysics Data System (ADS)

    Dalvi, Rupin; Hacihaliloglu, Ilker; Abugharbieh, Rafeef

    2010-03-01

    Stitching of volumes obtained from three dimensional (3D) ultrasound (US) scanners improves visualization of anatomy in many clinical applications. Fast but accurate volume registration remains the key challenge in this area.We propose a volume stitching method based on efficient registration of 3D US volumes obtained from a tracked US probe. Since the volumes, after adjusting for probe motion, are coarsely registered, we obtain salient correspondence points in the central slices of these volumes. This is done by first removing artifacts in the US slices using intensity invariant local phase image processing and then applying the Harris Corner detection algorithm. Fast sub-volume registration on a small neighborhood around the points then gives fast, accurate 3D registration parameters. The method has been tested on 3D US scans of phantom and real human radius and pelvis bones and a phantom human fetus. The method has also been compared to volumetric registration, as well as feature based registration using 3D-SIFT. Quantitative results show average post-registration error of 0.33mm which is comparable to volumetric registration accuracy (0.31mm) and much better than 3D-SIFT based registration which failed to register the volumes. The proposed method was also much faster than volumetric registration (~4.5 seconds versus 83 seconds).

  20. A simple high-performance liquid chromatography for the determination of linezolid in human plasma and saliva.

    PubMed

    Hara, Shuuji; Uchiyama, Masanobu; Yoshinari, Masami; Matsumoto, Taichi; Jimi, Shiro; Togawa, Atsushi; Takata, Tohru; Takamatsu, Yasushi

    2015-09-01

    Linezolid is an antimicrobial agent for the treatment of multiresistant Gram-positive infections. A practical high-performance liquid chromatography method was developed for the determination of linezolid in human plasma and saliva. Linezolid and an internal standard (o-ethoxybenzamide) were extracted from plasma and saliva with ethyl acetate and analyzed on a Capcell Pak C18 MG column with UV detection at 254 nm. The calibration curve was linear through the range 0.5-50 µg/mL using a 200 μL sample volume. The intra- and interday precisions were all <6.44% for plasma and 5.60% for saliva. The accuracies ranged from 98.8 to 110% for both matrices. The mean recoveries of linezolid were 80.8% for plasma and 79.0% for saliva. This method was used to determine the plasma and saliva concentrations of linezolid in healthy volunteers who were orally administered a 600 mg dose of linezolid. Our liquid-liquid extraction procedure is easy and requires a small volume of plasma or saliva (200 μL). This small volume can be advantageous in clinical pharmacokinetic studies, especially if children participate. Copyright © 2015 John Wiley & Sons, Ltd.

  1. The quantitative modelling of human spatial habitability

    NASA Technical Reports Server (NTRS)

    Wise, James A.

    1988-01-01

    A theoretical model for evaluating human spatial habitability (HuSH) in the proposed U.S. Space Station is developed. Optimizing the fitness of the space station environment for human occupancy will help reduce environmental stress due to long-term isolation and confinement in its small habitable volume. The development of tools that operationalize the behavioral bases of spatial volume for visual kinesthetic, and social logic considerations is suggested. This report further calls for systematic scientific investigations of how much real and how much perceived volume people need in order to function normally and with minimal stress in space-based settings. The theoretical model presented in this report can be applied to any size or shape interior, at any scale of consideration, for the Space Station as a whole to an individual enclosure or work station. Using as a point of departure the Isovist model developed by Dr. Michael Benedikt of the U. of Texas, the report suggests that spatial habitability can become as amenable to careful assessment as engineering and life support concerns.

  2. Addressable droplet microarrays for single cell protein analysis.

    PubMed

    Salehi-Reyhani, Ali; Burgin, Edward; Ces, Oscar; Willison, Keith R; Klug, David R

    2014-11-07

    Addressable droplet microarrays are potentially attractive as a way to achieve miniaturised, reduced volume, high sensitivity analyses without the need to fabricate microfluidic devices or small volume chambers. We report a practical method for producing oil-encapsulated addressable droplet microarrays which can be used for such analyses. To demonstrate their utility, we undertake a series of single cell analyses, to determine the variation in copy number of p53 proteins in cells of a human cancer cell line.

  3. Development of Metabolic Function Biomarkers in the Common Marmoset, Callithrix jacchus

    PubMed Central

    Ziegler, Toni E.; Colman, Ricki J.; Tardif, Suzette D.; Sosa, Megan E.; Wegner, Fredrick H.; Wittwer, Daniel J.; Shrestha, Hemanta

    2013-01-01

    Metabolic assessment of a nonhuman primate model of metabolic syndrome and obesity requires the necessary biomarkers specific to the species. While the rhesus monkey has a number of specific assays for assessing metabolic syndrome, the marmoset does not. Furthermore, the common marmoset (Callithrix jacchus) has a small blood volume that necessitates using a single blood volume for multiple analyses. The common marmoset holds a great potential as an alternative primate model for the study of human disease but assay methods need to be developed and validated for the biomarkers of metabolic syndrome. Here we report on the adaptation, development and validation of commercially available immunoassays for common marmoset samples in small volumes. We have performed biological validations for insulin, adiponectin, leptin, and ghrelin to demonstrate the use of these biomarkers in examining metabolic syndrome and other related diseases in the common marmoset. PMID:23447060

  4. Modulation of human sinus node function by systemic hypoxia

    NASA Technical Reports Server (NTRS)

    Eckberg, D. L.; Bastow, H., III; Scruby, A. E.

    1982-01-01

    The present study was conducted to determine whether bradycardia develops during systemic hypoxia in supine conscious human volunteers when respiratory frequency and tidal volume are maintained at constant levels. The obtained results suggest that mild hypoxia provokes cardioacceleration in humans, independent of changes of ventilation or baroreflex responsiveness. The earliest cardioacceleration is more prominent in the inspiratory than in the expiratory phase of respiration, and occurs with very small reductions of arterial oxygen saturation. Moderate systemic hypoxia dampens fluctuations of heart rate during the respiratory cycle.

  5. Photoactivated Composite Biomaterial for Soft Tissue Restoration in Rodents and in Humans

    PubMed Central

    Nahas, Zayna; Reid, Branden; Coburn, Jeannine M.; Axelman, Joyce; Chae, Jemin J.; Guo, Qiongyu; Trow, Robert; Thomas, Andrew; Hou, Zhipeng; Lichtsteiner, Serge; Sutton, Damon; Matheson, Christine; Walker, Patricia; David, Nathaniel; Mori, Susumu; Taube, Janis M.; Elisseeff, Jennifer H.

    2015-01-01

    Soft tissue reconstruction often requires multiple surgical procedures that can result in scars and disfiguration. Facial soft tissue reconstruction represents a clinical challenge because even subtle deformities can severely affect an individual’s social and psychological function. We therefore developed a biosynthetic soft tissue replacement composed of poly(ethylene glycol) (PEG) and hyaluronic acid (HA) that can be injected and photocrosslinked in situ with transdermal light exposure. Modulating the ratio of synthetic to biological polymer allowed us to tune implant elasticity and volume persistence. In a small-animal model, implanted photocrosslinked PEG-HA showed a dose-dependent relationship between increasing PEG concentration and enhanced implant volume persistence. In direct comparison with commercial HA injections, the PEG-HA implants maintained significantly greater average volumes and heights. Reversibility of the implant volume was achieved with hyaluronidase injection. Pilot clinical testing in human patients confirmed the feasibility of the transdermal photocrosslinking approach for implantation in abdomen soft tissue, although an inflammatory response was observed surrounding some of the materials. PMID:21795587

  6. Determination of Urea Permeability in Red Cells by Minimum Method

    PubMed Central

    Sha'afi, R. I.; Rich, G. T.; Mikulecky, D. C.; Solomon, A. K.

    1970-01-01

    A new method has been developed for measuring the permeability coefficient, ω, of small nonelectrolytes. The method depends upon a mathematical analysis of the time course of cell volume changes in the neighborhood of the minimum volume following addition of a permeating solute to an isosmolal buffer. Coefficients determined by the minimum volume method agree with those obtained using radioactive tracers. ω for urea in human red cells was found to decrease as the volume flow, Jv, into the cell increased. Such behavior is entirely unexpected for a single uniform rate-limiting barrier on the basis of the linear phenomenological equations derived from irreversible thermodynamics. However, the present findings are consonant with a complex membrane system consisting of a tight barrier on the outer face of the human red cell membrane and a somewhat less restrictive barrier behind it closer to the inner membrane face. A theoretical analysis of such a series model has been made which makes predictions consistent with the experimental findings. PMID:5435779

  7. A Modified LC/MS/MS Method with Enhanced Sensitivity for the Determination of Scopolamine in Human Plasma

    NASA Technical Reports Server (NTRS)

    Wang, Zuwei; Vaksman, Zalman; Putcha, Lakshmi

    2008-01-01

    Intranasal scopolamine is a choice drug for the treatment of motion sickness during space flight because of its quick onset of action, short half-life and favorable sideeffects profile. The dose administered usually ranges between 0.1 and 0.4 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids using existing sensitive LC/MS/MS method, especially when the biological sample volumes are limited. To measure scopolamine in human plasma to facilitate pharmacokinetic evaluation of the drug, we developed a sensitive LC/MS/MS method using 96 well micro elution plates for solid phase extraction (SPE) of scopolamine in human plasma. Human plasma (100-250 micro L) were loaded onto Waters Oasis HLB 96 well micro elution plate and eluted with 50 L of organic solvent without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 3 minutes. The mobile phase for separation was 80:20 (v/v) methanol: ammonium acetate (30 mM) in water. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 right arrow 138.1 and internal standard hyoscyamine m/z = 290.2 right arrow 124.1. The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at about 1.1 and 1.7 min respectively. The linear range is 25-10000 pg/mL for scopolamine in human plasma with correlation coefficients greater than 0.99 and CV less than 0.5%. The intra-day and inter-day CVs are less than 15% for quality control samples with concentrations of 75,300, and 750 pg/mL of scopolamine in human plasma. SPE using 96 well micro elution plates allows rapid sample preparation and enhanced sensitivity for the LC/MS/MS determination of scopolamine in a small volume of biological samples. The new method is also cost effective since it uses a small volume of organic solvents compared to the methods using SPE cartridges or regular 96 well SPE plates. This method can be successfully used for bioavailability and pharmacokinetic evaluations of scopolamine, especially when volumes of biological samples are limited. Further investigation to use automated SPE system with 96 well micro elution plates is planned.

  8. Identification of common variants associated with human hippocampal and intracranial volumes

    PubMed Central

    Stein, Jason L; Medland, Sarah E; Vasquez, Alejandro Arias; Hibar, Derrek P; Senstad, Rudy E; Winkler, Anderson M; Toro, Roberto; Appel, Katja; Bartecek, Richard; Bergmann, Ørjan; Bernard, Manon; Brown, Andrew A; Cannon, Dara M; Chakravarty, M Mallar; Christoforou, Andrea; Domin, Martin; Grimm, Oliver; Hollinshead, Marisa; Holmes, Avram J; Homuth, Georg; Hottenga, Jouke-Jan; Langan, Camilla; Lopez, Lorna M; Hansell, Narelle K; Hwang, Kristy S; Kim, Sungeun; Laje, Gonzalo; Lee, Phil H; Liu, Xinmin; Loth, Eva; Lourdusamy, Anbarasu; Mattingsdal, Morten; Mohnke, Sebastian; Maniega, Susana Muñoz; Nho, Kwangsik; Nugent, Allison C; O’Brien, Carol; Papmeyer, Martina; Pütz, Benno; Ramasamy, Adaikalavan; Rasmussen, Jerod; Rijpkema, Mark; Risacher, Shannon L; Roddey, J Cooper; Rose, Emma J; Ryten, Mina; Shen, Li; Sprooten, Emma; Strengman, Eric; Teumer, Alexander; Trabzuni, Daniah; Turner, Jessica; van Eijk, Kristel; van Erp, Theo G M; van Tol, Marie-Jose; Wittfeld, Katharina; Wolf, Christiane; Woudstra, Saskia; Aleman, Andre; Alhusaini, Saud; Almasy, Laura; Binder, Elisabeth B; Brohawn, David G; Cantor, Rita M; Carless, Melanie A; Corvin, Aiden; Czisch, Michael; Curran, Joanne E; Davies, Gail; de Almeida, Marcio A A; Delanty, Norman; Depondt, Chantal; Duggirala, Ravi; Dyer, Thomas D; Erk, Susanne; Fagerness, Jesen; Fox, Peter T; Freimer, Nelson B; Gill, Michael; Göring, Harald H H; Hagler, Donald J; Hoehn, David; Holsboer, Florian; Hoogman, Martine; Hosten, Norbert; Jahanshad, Neda; Johnson, Matthew P; Kasperaviciute, Dalia; Kent, Jack W; Kochunov, Peter; Lancaster, Jack L; Lawrie, Stephen M; Liewald, David C; Mandl, René; Matarin, Mar; Mattheisen, Manuel; Meisenzahl, Eva; Melle, Ingrid; Moses, Eric K; Mühleisen, Thomas W; Nauck, Matthias; Nöthen, Markus M; Olvera, Rene L; Pandolfo, Massimo; Pike, G Bruce; Puls, Ralf; Reinvang, Ivar; Rentería, Miguel E; Rietschel, Marcella; Roffman, Joshua L; Royle, Natalie A; Rujescu, Dan; Savitz, Jonathan; Schnack, Hugo G; Schnell, Knut; Seiferth, Nina; Smith, Colin; Steen, Vidar M; Valdés Hernández, Maria C; Van den Heuvel, Martijn; van der Wee, Nic J; Van Haren, Neeltje E M; Veltman, Joris A; Völzke, Henry; Walker, Robert; Westlye, Lars T; Whelan, Christopher D; Agartz, Ingrid; Boomsma, Dorret I; Cavalleri, Gianpiero L; Dale, Anders M; Djurovic, Srdjan; Drevets, Wayne C; Hagoort, Peter; Hall, Jeremy; Heinz, Andreas; Jack, Clifford R; Foroud, Tatiana M; Le Hellard, Stephanie; Macciardi, Fabio; Montgomery, Grant W; Poline, Jean Baptiste; Porteous, David J; Sisodiya, Sanjay M; Starr, John M; Sussmann, Jessika; Toga, Arthur W; Veltman, Dick J; Walter, Henrik; Weiner, Michael W; Bis, Joshua C; Ikram, M Arfan; Smith, Albert V; Gudnason, Vilmundur; Tzourio, Christophe; Vernooij, Meike W; Launer, Lenore J; DeCarli, Charles; Seshadri, Sudha; Andreassen, Ole A; Apostolova, Liana G; Bastin, Mark E; Blangero, John; Brunner, Han G; Buckner, Randy L; Cichon, Sven; Coppola, Giovanni; de Zubicaray, Greig I; Deary, Ian J; Donohoe, Gary; de Geus, Eco J C; Espeseth, Thomas; Fernández, Guillén; Glahn, David C; Grabe, Hans J; Hardy, John; Hulshoff Pol, Hilleke E; Jenkinson, Mark; Kahn, René S; McDonald, Colm; McIntosh, Andrew M; McMahon, Francis J; McMahon, Katie L; Meyer-Lindenberg, Andreas; Morris, Derek W; Müller-Myhsok, Bertram; Nichols, Thomas E; Ophoff, Roel A; Paus, Tomas; Pausova, Zdenka; Penninx, Brenda W; Potkin, Steven G; Sämann, Philipp G; Saykin, Andrew J; Schumann, Gunter; Smoller, Jordan W; Wardlaw, Joanna M; Weale, Michael E; Martin, Nicholas G; Franke, Barbara; Wright, Margaret J; Thompson, Paul M

    2013-01-01

    Identifying genetic variants influencing human brain structures may reveal new biological mechanisms underlying cognition and neuropsychiatric illness. The volume of the hippocampus is a biomarker of incipient Alzheimer’s disease1,2 and is reduced in schizophrenia3, major depression4 and mesial temporal lobe epilepsy5. Whereas many brain imaging phenotypes are highly heritable6,7, identifying and replicating genetic influences has been difficult, as small effects and the high costs of magnetic resonance imaging (MRI) have led to underpowered studies. Here we report genome-wide association meta-analyses and replication for mean bilateral hippocampal, total brain and intracranial volumes from a large multinational consortium. The intergenic variant rs7294919 was associated with hippocampal volume (12q24.22; N = 21,151; P = 6.70 × 10−16) and the expression levels of the positional candidate gene TESC in brain tissue. Additionally, rs10784502, located within HMGA2, was associated with intracranial volume (12q14.3; N = 15,782; P = 1.12 × 10−12). We also identified a suggestive association with total brain volume at rs10494373 within DDR2 (1q23.3; N = 6,500; P = 5.81 × 10−7). PMID:22504417

  9. 75 FR 29605 - Clean Alternative Fuel Vehicle and Engine Conversions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-26

    ... Small Volume Manufacturers and Small Volume Test Groups 1. Definition of Small Volume Manufacturers, Small Volume Test Groups, and Small Volume Engine Families a. Light-Duty and Heavy-Duty Complete... and Engines 2. Test Groups, Engine Families, and Evaporative Families a. Test Groups for Light-Duty...

  10. Preliminary report on macroscopic age changes in the human prosencephalon. A stereologic investigation.

    PubMed

    Eggers, R; Haug, H; Fischer, D

    1984-01-01

    The studies here reported were performed on the prosencephalons of 12 human brains between 37 and 86 years of age having no signs of neuropathological alteration. The evaluation was carried out on serial frontal sections with a mean thickness of 5 mm with stereological point counting procedures for volume and surface area. The results were mainly given in relative values since the range of variation is very high and the sample small. The aging process was evaluated with the aid of a linear regression function. The stereological investigation regarding the absolute values of volume and surface area (border face) of the macroscopical brain parts show a high interindividual variability. However, the relative volume of brain parts shows only small variations. Changes during aging could consequently only be revealed with the help of the relative values. The relative volumes and surface areas of the frontal lobe and the prosencephalic ganglia decrease with aging, while the parieto-occipital lobe and the striate cortex increase. However, if we refer these relative increases to the absolute decrease of brain volume, corresponding changes cannot be found in the parieto-occipital lobe until old age. The shrinkage of the frontal lobe, of the centrum semiovale and of the prosencephalic ganglia exceeds 10%. In the grays it is probably accompanied by a loss of neurons. The relative sizes of the surface area do not change significantly during aging with exception of the frontal cortex. The thickness of the cortex remains probably constant. The size of lateral ventricles increases with aging.

  11. Suitability of frequency modulated thermal wave imaging for skin cancer detection-A theoretical prediction.

    PubMed

    Bhowmik, Arka; Repaka, Ramjee; Mulaveesala, Ravibabu; Mishra, Subhash C

    2015-07-01

    A theoretical study on the quantification of surface thermal response of cancerous human skin using the frequency modulated thermal wave imaging (FMTWI) technique has been presented in this article. For the first time, the use of the FMTWI technique for the detection and the differentiation of skin cancer has been demonstrated in this article. A three dimensional multilayered skin has been considered with the counter-current blood vessels in individual skin layers along with different stages of cancerous lesions based on geometrical, thermal and physical parameters available in the literature. Transient surface thermal responses of melanoma during FMTWI of skin cancer have been obtained by integrating the heat transfer model for biological tissue along with the flow model for blood vessels. It has been observed from the numerical results that, flow of blood in the subsurface region leads to a substantial alteration on the surface thermal response of the human skin. The alteration due to blood flow further causes a reduction in the performance of the thermal imaging technique during the thermal evaluation of earliest melanoma stages (small volume) compared to relatively large volume. Based on theoretical study, it has been predicted that the method is suitable for detection and differentiation of melanoma with comparatively large volume than the earliest development stages (small volume). The study has also performed phase based image analysis of the raw thermograms to resolve the different stages of melanoma volume. The phase images have been found to be clearly individuate the different development stages of melanoma compared to raw thermograms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. 40 CFR Appendix 7 to Subpart A of... - Determination of the Amount of Non-Aqueous Drilling Fluid (NAF) Base Fluid From Drill Cuttings by...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... multiplying the density of the small volume NAF-cuttings discharges (ρsvd) times the volume of the small...-cuttings discharges (kg) ρsvd = density of the small volume NAF-cuttings discharges (kg/bbl) VSVD = volume of the small volume NAF-cuttings discharges (bbl) The density of the small volume NAF-cuttings...

  13. 40 CFR Appendix 7 to Subpart A of... - Determination of the Amount of Non-Aqueous Drilling Fluid (NAF) Base Fluid From Drill Cuttings by...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... multiplying the density of the small volume NAF-cuttings discharges (ρsvd) times the volume of the small...-cuttings discharges (kg) ρsvd = density of the small volume NAF-cuttings discharges (kg/bbl) VSVD = volume of the small volume NAF-cuttings discharges (bbl) The density of the small volume NAF-cuttings...

  14. 40 CFR Appendix 7 to Subpart A of... - Determination of the Amount of Non-Aqueous Drilling Fluid (NAF) Base Fluid From Drill Cuttings by...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... multiplying the density of the small volume NAF-cuttings discharges (ρsvd) times the volume of the small...-cuttings discharges (kg) ρsvd = density of the small volume NAF-cuttings discharges (kg/bbl) VSVD = volume of the small volume NAF-cuttings discharges (bbl) The density of the small volume NAF-cuttings...

  15. Brain anatomical networks in early human brain development.

    PubMed

    Fan, Yong; Shi, Feng; Smith, Jeffrey Keith; Lin, Weili; Gilmore, John H; Shen, Dinggang

    2011-02-01

    Recent neuroimaging studies have demonstrated that human brain networks have economic small-world topology and modular organization, enabling efficient information transfer among brain regions. However, it remains largely unknown how the small-world topology and modular organization of human brain networks emerge and develop. Using longitudinal MRI data of 28 healthy pediatric subjects, collected at their ages of 1 month, 1 year, and 2 years, we analyzed development patterns of brain anatomical networks derived from morphological correlations of brain regional volumes. The results show that the brain network of 1-month-olds has the characteristically economic small-world topology and nonrandom modular organization. The network's cost efficiency increases with the brain development to 1 year and 2 years, so does the modularity, providing supportive evidence for the hypothesis that the small-world topology and the modular organization of brain networks are established during early brain development to support rapid synchronization and information transfer with minimal rewiring cost, as well as to balance between local processing and global integration of information. Copyright © 2010. Published by Elsevier Inc.

  16. Oceanography: the present and future

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brewer, P.G.

    This volume is the proceedings of a symposium held September 29 to October 2, 1980 at Woods Hole, Massachusetts, commemorating the 50th anniversary of the founding of the Woods Hole Oceanographic Institution. The book is the companion volume to ''Oceanography: the Past'' also published by Springer-Verlag. The papers are organized not by conventional disciplinary topics but by the ''scale'' of the oceanographic process: Part I, Small and Local Scale Oceanography; Part II, Regional Scale Oceanography; Part III, Global Scale Oceanography; and Part IV, The Human Scale. The articles presented, however, do not summarize such projects but give recognizable disciplinary summariesmore » and predictions in line with the subtitle of the book. In general, the articles are classed by this scale concept, although ''Shoreline Research'' by Pilkey and ''The Oceans Nearby'' by Murphy are better placed in the section The Human Scale and Bolin's ''Changing Global Biogeochemistry'' switched from The Human Scale to Global Scale as indicated by the title. This volume should be of value to marine geologists and geochemists, sedimentologists, and public-interest (environmental) geologists interested in oceanographic processes.« less

  17. Volumetry of human taste buds using laser scanning microscopy.

    PubMed

    Just, T; Srur, E; Stachs, O; Pau, H W

    2009-10-01

    In vivo laser scanning confocal microscopy is a relatively new, non-invasive method for assessment of oral cavity epithelia. The penetration depth of approximately 200-400 microm allows visualisation of fungiform papillae and their taste buds. This paper describes the technique of in vivo volumetry of human taste buds. Confocal laser scanning microscopy used a diode laser at 670 nm for illumination. Digital laser scanning confocal microscopy equipment consisted of the Heidelberg Retina Tomograph HRTII and the Rostock Cornea Module. Volume scans of fungiform papillae were used for three-dimensional reconstruction of the taste bud. This technique supplied information on taste bud structure and enabled measurement and calculation of taste bud volume. Volumetric data from a 23-year-old man over a nine-day period showed only a small deviation in values. After three to four weeks, phenomenological changes in taste bud structures were found (i.e. a significant increase in volume, followed by disappearance of the taste bud and appearance of a new taste bud). The data obtained indicate the potential application of this non-invasive imaging modality: to evaluate variation of taste bud volume in human fungiform papillae with ageing; to study the effects of chorda tympani nerve transection on taste bud volume; and to demonstrate recovery of taste buds in patients with a severed chorda tympani nerve who show recovery of gustatory sensibility after surgery.

  18. In vitro and in vivo investigation of taste-masking effectiveness of Eudragit E PO as drug particle coating agent in orally disintegrating tablets.

    PubMed

    Drašković, Milica; Medarević, Djordje; Aleksić, Ivana; Parojčić, Jelena

    2017-05-01

    Considering that bitter taste of drugs incorporated in orally disintegrating tablets (ODTs) can be the main reason for avoiding drug therapy, it is of the utmost importance to achieve successful taste-masking. The evaluation of taste-masking effectiveness is still a major challenge. The objective of this study was to mask bitter taste of the selected model drugs by drug particle coating with Eudragit ® E PO, as well as to evaluate taste-masking effectiveness of prepared ODTs using compendial dissolution testing, dissolution in the small-volume shake-flask assembly and trained human taste panel. Model drugs were coated in fluidized bed. Disintequik™ ODT was used as a novel co-processed excipient for ODT preparation. Selected formulations were investigated in vitro and in vivo using techniques for taste-masking assessment. Significantly slower drug dissolution was observed from tablets with coated drug particles during the first 3 min of investigation. Results of in vivo taste-masking assessment demonstrated significant improvement in drug bitterness suppression in formulations with coated drug. Strong correlation between the results of drug dissolution in the small-volume shake-flask assembly and in vivo evaluation data was established (R ≥ 0.970). Drug particle coating with Eudragit ® E PO can be a suitable approach for bitter taste-masking. Strong correlation between in vivo and in vitro results implicate that small-volume dissolution method may be used as surrogate for human panel taste-masking assessment, in the case of physical taste-masking approach application.

  19. The Effects of Reducing the Structural Mass of the Transit Habitat on the Cryogenic Propellant Required for a Human Phobos Mission

    NASA Technical Reports Server (NTRS)

    Zipay, John Joseph

    2016-01-01

    A technique for rapidly determining the relationship between the pressurized volume, structural mass and the cryogenic propellant required to be delivered to Earth orbit for a Mars Transit Habitat is provided. This technique is based on assumptions for the required delta-V's, the Exploration Upper Stage performance and the historical structural masses for human spacecraft from Mercury Program through the International Space Station. If the Mars Transit Habitat is constructed from aluminum, structural mass estimates based on the habitat pressurized volume are accurate to within 15%. Other structural material options for the Mars Transit Habitat are also evaluated. The results show that small, achievable reductions in the structural mass of the Transit Habitat can save tens of thousands of pounds of cryogenic propellant that need to be delivered to Earth orbit for a human Phobos Mission.

  20. The Effects of Reducing the Structural Mass of the Transit Habitat on the Cryogenic Propellant Required for a Human Phobos Mission

    NASA Technical Reports Server (NTRS)

    Zipay, John J.

    2016-01-01

    A technique for rapidly determining the relationship between the pressurized volume, structural mass and the cryogenic propellant required to be delivered to Earth orbit for a Mars Transit Habitat is provided. This technique is based on assumptions for the required delta-V's, the Exploration Upper Stage performance and the historical structural masses for human spacecraft from Mercury Program through the International Space Station. If the Mars Transit Habitat is constructed from aluminum, structural mass estimates based on the habitat pressurized volume are accurate to within 15 percent. Other structural material options for the Mars Transit Habitat are also evaluated. The results show that small, achievable reductions in the structural mass of the Transit Habitat can save tens of thousands of pounds of cryogenic propellant that need to be delivered to Earth orbit for a human Phobos Mission.

  1. Translating Research Into Practice: Voluntary Reporting of Medication Errors in Critical Access Hospitals

    ERIC Educational Resources Information Center

    Jones, Katherine J.; Cochran, Gary; Hicks, Rodney W.; Mueller, Keith J.

    2004-01-01

    Context:Low service volume, insufficient information technology, and limited human resources are barriers to learning about and correcting system failures in small rural hospitals. This paper describes the implementation of and initial findings from a voluntary medication error reporting program developed by the Nebraska Center for Rural Health…

  2. Night Attack Workload Steering Group. Volume 3. Simulation and Human Factors Subgroup

    DTIC Science & Technology

    1982-06-01

    information intepretation . The second is the use of pictorial formats or computer generated displays that combine many present-day displays into a small number...base exists in any form (digital, film , or model) which supports the wide area, long track, low level requirements levied by night attack training

  3. Marin County Teacher Learning Cooperative: Phase II, Volume 1.

    ERIC Educational Resources Information Center

    Balzan, Robert A.

    This report describes the second phase of a teacher learning cooperative project designed to coordinate the economic, physical, and human resources of a number of small elementary school districts in California and the Marin County Superintendent of Schools Office. Whereas the first phase dealt with the formation and implementation of the…

  4. Marin County Teacher Learning Cooperative: Phase II, Volume 2.

    ERIC Educational Resources Information Center

    Balzan, Robert A.

    This report describes the second phase of a teacher learning cooperative project designed to coordinate the economic, physical, and human resources of a number of small elementary school districts in California and the Marin County Superintendent of Schools Office. Whereas the first phase dealt with the formation and implementation of the…

  5. Innovation in Deep Space Habitat Interior Design: Lessons Learned From Small Space Design in Terrestrial Architecture

    NASA Technical Reports Server (NTRS)

    Simon, Matthew A.; Toups, Larry

    2014-01-01

    Increased public awareness of carbon footprints, crowding in urban areas, and rising housing costs have spawned a 'small house movement' in the housing industry. Members of this movement desire small, yet highly functional residences which are both affordable and sensitive to consumer comfort standards. In order to create comfortable, minimum-volume interiors, recent advances have been made in furniture design and approaches to interior layout that improve both space utilization and encourage multi-functional design for small homes, apartments, naval, and recreational vehicles. Design efforts in this evolving niche of terrestrial architecture can provide useful insights leading to innovation and efficiency in the design of space habitats for future human space exploration missions. This paper highlights many of the cross-cutting architectural solutions used in small space design which are applicable to the spacecraft interior design problem. Specific solutions discussed include reconfigurable, multi-purpose spaces; collapsible or transformable furniture; multi-purpose accommodations; efficient, space saving appliances; stowable and mobile workstations; and the miniaturization of electronics and computing hardware. For each of these design features, descriptions of how they save interior volume or mitigate other small space issues such as confinement stress or crowding are discussed. Finally, recommendations are provided to provide guidance for future designs and identify potential collaborations with the small spaces design community.

  6. Integrating quantitative PCR and Bayesian statistics in quantifying human adenoviruses in small volumes of source water.

    PubMed

    Wu, Jianyong; Gronewold, Andrew D; Rodriguez, Roberto A; Stewart, Jill R; Sobsey, Mark D

    2014-02-01

    Rapid quantification of viral pathogens in drinking and recreational water can help reduce waterborne disease risks. For this purpose, samples in small volume (e.g. 1L) are favored because of the convenience of collection, transportation and processing. However, the results of viral analysis are often subject to uncertainty. To overcome this limitation, we propose an approach that integrates Bayesian statistics, efficient concentration methods, and quantitative PCR (qPCR) to quantify viral pathogens in water. Using this approach, we quantified human adenoviruses (HAdVs) in eighteen samples of source water collected from six drinking water treatment plants. HAdVs were found in seven samples. In the other eleven samples, HAdVs were not detected by qPCR, but might have existed based on Bayesian inference. Our integrated approach that quantifies uncertainty provides a better understanding than conventional assessments of potential risks to public health, particularly in cases when pathogens may present a threat but cannot be detected by traditional methods. © 2013 Elsevier B.V. All rights reserved.

  7. Centrifuge Facility Conceptual System Study. Volume 1: Facility overview and habitats

    NASA Technical Reports Server (NTRS)

    Synnestvedt, Robert (Editor)

    1990-01-01

    The results are presented for a NASA Phase 1 study conducted from mid 1987 through mid 1989 at Ames Research Center. The Centrifuge Facility is the major element of the biological research facility for the implementation of NASA's Life Science Research Program on Space Station Freedom using non-human specimens (such as small primates, rodents, plants, insects, cell tissues). Five systems are described which comprise the Facility: habitats, holding units, centrifuge, glovebox, and service unit. Volume 1 presents a facility overview and describes the habitats - modular units which house living specimens.

  8. Monitoring tumor growth and treatment in small animals with magnetic resonance and optical tomographic imaging

    NASA Astrophysics Data System (ADS)

    Masciotti, J.; Provenzano, F.; Papa, J.; Klose, A.; Hur, J.; Gu, X.; Yamashiro, D.; Kandel, J.; Hielscher, A. H.

    2006-02-01

    Small animal models are employed to simulate disease in humans and to study its progression, what factors are important to the disease process, and to study the disease treatment. Biomedical imaging modalities such as magnetic resonance imaging (MRI) and Optical Tomography make it possible to non-invasively monitor the progression of diseases in living small animals and study the efficacy of drugs and treatment protocols. MRI is an established imaging modality capable of obtaining high resolution anatomical images and along with contrast agents allow the studying of blood volume. Optical tomography, on the other hand, is an emerging imaging modality, which, while much lower in spatial resolution, can separate the effects of oxyhemoglobin, deoxyhemoglobin, and blood volume with high temporal resolution. In this study we apply these modalities to imaging the growth of kidney tumors and then there treatment by an anti-VEGF agent. We illustrate how these imaging modalities have their individual uses, but can still supplement each other and cross validation can be performed.

  9. Enhanced FIB-SEM systems for large-volume 3D imaging.

    PubMed

    Xu, C Shan; Hayworth, Kenneth J; Lu, Zhiyuan; Grob, Patricia; Hassan, Ahmed M; García-Cerdán, José G; Niyogi, Krishna K; Nogales, Eva; Weinberg, Richard J; Hess, Harald F

    2017-05-13

    Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) can automatically generate 3D images with superior z-axis resolution, yielding data that needs minimal image registration and related post-processing. Obstacles blocking wider adoption of FIB-SEM include slow imaging speed and lack of long-term system stability, which caps the maximum possible acquisition volume. Here, we present techniques that accelerate image acquisition while greatly improving FIB-SEM reliability, allowing the system to operate for months and generating continuously imaged volumes > 10 6 µm 3 . These volumes are large enough for connectomics, where the excellent z resolution can help in tracing of small neuronal processes and accelerate the tedious and time-consuming human proofreading effort. Even higher resolution can be achieved on smaller volumes. We present example data sets from mammalian neural tissue, Drosophila brain, and Chlamydomonas reinhardtii to illustrate the power of this novel high-resolution technique to address questions in both connectomics and cell biology.

  10. Loss in lung volume and changes in the immune response demonstrate disease progression in African green monkeys infected by small-particle aerosol and intratracheal exposure to Nipah virus.

    PubMed

    Cong, Yu; Lentz, Margaret R; Lara, Abigail; Alexander, Isis; Bartos, Christopher; Bohannon, J Kyle; Hammoud, Dima; Huzella, Louis; Jahrling, Peter B; Janosko, Krisztina; Jett, Catherine; Kollins, Erin; Lackemeyer, Matthew; Mollura, Daniel; Ragland, Dan; Rojas, Oscar; Solomon, Jeffrey; Xu, Ziyue; Munster, Vincent; Holbrook, Michael R

    2017-04-01

    Nipah virus (NiV) is a paramyxovirus (genus Henipavirus) that emerged in the late 1990s in Malaysia and has since been identified as the cause of sporadic outbreaks of severe febrile disease in Bangladesh and India. NiV infection is frequently associated with severe respiratory or neurological disease in infected humans with transmission to humans through inhalation, contact or consumption of NiV contaminated foods. In the work presented here, the development of disease was investigated in the African Green Monkey (AGM) model following intratracheal (IT) and, for the first time, small-particle aerosol administration of NiV. This study utilized computed tomography (CT) and magnetic resonance imaging (MRI) to temporally assess disease progression. The host immune response and changes in immune cell populations over the course of disease were also evaluated. This study found that IT and small-particle administration of NiV caused similar disease progression, but that IT inoculation induced significant congestion in the lungs while disease following small-particle aerosol inoculation was largely confined to the lower respiratory tract. Quantitative assessment of changes in lung volume found up to a 45% loss in IT inoculated animals. None of the subjects in this study developed overt neurological disease, a finding that was supported by MRI analysis. The development of neutralizing antibodies was not apparent over the 8-10 day course of disease, but changes in cytokine response in all animals and activated CD8+ T cell numbers suggest the onset of cell-mediated immunity. These studies demonstrate that IT and small-particle aerosol infection with NiV in the AGM model leads to a severe respiratory disease devoid of neurological indications. This work also suggests that extending the disease course or minimizing the impact of the respiratory component is critical to developing a model that has a neurological component and more accurately reflects the human condition.

  11. Loss in lung volume and changes in the immune response demonstrate disease progression in African green monkeys infected by small-particle aerosol and intratracheal exposure to Nipah virus

    PubMed Central

    Cong, Yu; Lentz, Margaret R.; Lara, Abigail; Alexander, Isis; Bartos, Christopher; Bohannon, J. Kyle; Hammoud, Dima; Huzella, Louis; Jahrling, Peter B.; Janosko, Krisztina; Jett, Catherine; Kollins, Erin; Lackemeyer, Matthew; Mollura, Daniel; Ragland, Dan; Rojas, Oscar; Solomon, Jeffrey; Xu, Ziyue; Munster, Vincent

    2017-01-01

    Nipah virus (NiV) is a paramyxovirus (genus Henipavirus) that emerged in the late 1990s in Malaysia and has since been identified as the cause of sporadic outbreaks of severe febrile disease in Bangladesh and India. NiV infection is frequently associated with severe respiratory or neurological disease in infected humans with transmission to humans through inhalation, contact or consumption of NiV contaminated foods. In the work presented here, the development of disease was investigated in the African Green Monkey (AGM) model following intratracheal (IT) and, for the first time, small-particle aerosol administration of NiV. This study utilized computed tomography (CT) and magnetic resonance imaging (MRI) to temporally assess disease progression. The host immune response and changes in immune cell populations over the course of disease were also evaluated. This study found that IT and small-particle administration of NiV caused similar disease progression, but that IT inoculation induced significant congestion in the lungs while disease following small-particle aerosol inoculation was largely confined to the lower respiratory tract. Quantitative assessment of changes in lung volume found up to a 45% loss in IT inoculated animals. None of the subjects in this study developed overt neurological disease, a finding that was supported by MRI analysis. The development of neutralizing antibodies was not apparent over the 8–10 day course of disease, but changes in cytokine response in all animals and activated CD8+ T cell numbers suggest the onset of cell-mediated immunity. These studies demonstrate that IT and small-particle aerosol infection with NiV in the AGM model leads to a severe respiratory disease devoid of neurological indications. This work also suggests that extending the disease course or minimizing the impact of the respiratory component is critical to developing a model that has a neurological component and more accurately reflects the human condition. PMID:28388650

  12. Meta-analysis of associations between human brain volume and intelligence differences: How strong are they and what do they mean?

    PubMed

    Pietschnig, Jakob; Penke, Lars; Wicherts, Jelte M; Zeiler, Michael; Voracek, Martin

    2015-10-01

    Positive associations between human intelligence and brain size have been suspected for more than 150 years. Nowadays, modern non-invasive measures of in vivo brain volume (Magnetic Resonance Imaging) make it possible to reliably assess associations with IQ. By means of a systematic review of published studies and unpublished results obtained by personal communications with researchers, we identified 88 studies examining effect sizes of 148 healthy and clinical mixed-sex samples (>8000 individuals). Our results showed significant positive associations of brain volume and IQ (r=.24, R(2)=.06) that generalize over age (children vs. adults), IQ domain (full-scale, performance, and verbal IQ), and sex. Application of a number of methods for detection of publication bias indicates that strong and positive correlation coefficients have been reported frequently in the literature whilst small and non-significant associations appear to have been often omitted from reports. We show that the strength of the positive association of brain volume and IQ has been overestimated in the literature, but remains robust even when accounting for different types of dissemination bias, although reported effects have been declining over time. While it is tempting to interpret this association in the context of human cognitive evolution and species differences in brain size and cognitive ability, we show that it is not warranted to interpret brain size as an isomorphic proxy of human intelligence differences. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Volumetric Modulated Arc (Radio) Therapy in Pets Treatment: The “La Cittadina Fondazione” Experience

    PubMed Central

    Dolera, Mario; Malfassi, Luca; Carrara, Nancy; Finesso, Sara; Marcarini, Silvia; Mazza, Giovanni; Pavesi, Simone; Sala, Massimo; Urso, Gaetano

    2018-01-01

    Volumetric Modulated Arc Therapy (VMAT) is a modern technique, widely used in human radiotherapy, which allows a high dose to be delivered to tumor volumes and low doses to the surrounding organs at risk (OAR). Veterinary clinics takes advantage of this feature due to the small target volumes and distances between the target and the OAR. Sparing the OAR permits dose escalation, and hypofractionation regimens reduce the number of treatment sessions with a simpler manageability in the veterinary field. Multimodal volumes definition is mandatory for the small volumes involved and a positioning device precisely reproducible with a setup confirmation is needed before each session for avoiding missing the target. Additionally, the elaborate treatment plan must pursue hard constraints and objectives, and its feasibility must be evaluated with a per patient quality control. The aim of this work is to report results with regard to brain meningiomas and gliomas, trigeminal nerve tumors, brachial plexus tumors, adrenal tumors with vascular invasion and rabbit thymomas, in comparison with literature to determine if VMAT is a safe and viable alternative to surgery or chemotherapy alone, or as an adjuvant therapy in pets. PMID:29364837

  14. 40 CFR 86.1826-01 - Assigned deterioration factors for small volume manufacturers and small volume test groups.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... durability groups) that is equipped with unproven emission control systems. (v) The manufacturer must... small volume manufacturers and small volume test groups. 86.1826-01 Section 86.1826-01 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW...

  15. 40 CFR 86.1826-01 - Assigned deterioration factors for small volume manufacturers and small volume test groups.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... durability groups) that is equipped with unproven emission control systems. (v) The manufacturer must... small volume manufacturers and small volume test groups. 86.1826-01 Section 86.1826-01 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW...

  16. 40 CFR 86.1826-01 - Assigned deterioration factors for small volume manufacturers and small volume test groups.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... durability groups) that is equipped with unproven emission control systems. (v) The manufacturer must... small volume manufacturers and small volume test groups. 86.1826-01 Section 86.1826-01 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW...

  17. 40 CFR 86.1826-01 - Assigned deterioration factors for small volume manufacturers and small volume test groups.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... durability groups) that is equipped with unproven emission control systems. (v) The manufacturer must... small volume manufacturers and small volume test groups. 86.1826-01 Section 86.1826-01 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW...

  18. CTC Sentinel. Volume 1, Issue 6, May 2008. Abu Yahya al-Libi’s Human Shields in Modern Jihad

    DTIC Science & Technology

    2008-05-01

    own include The Healing of the Believers’ Chests and The Exoneration. 7 Although the essay is dated January 6, 2006, it was not published and widely...Yahya’s small essay on al-Tatarrus is nothing short of a religious revolution. Early Islamic thinkers typically used three general forms of shielding...traditional Islamic discussions in that it simplifies mat- ters considerably. MAY 2008 . VoL 1 . IssUE 6 “Abu Yahya’s small essay on al-Tatarrus is nothing

  19. The Use of Silk as a Scaffold for Mature, Sustainable Unilocular Adipose 3D Tissue Engineered Systems.

    PubMed

    Abbott, Rosalyn D; Wang, Rebecca Y; Reagan, Michaela R; Chen, Ying; Borowsky, Francis E; Zieba, Adam; Marra, Kacey G; Rubin, J Peter; Ghobrial, Irene M; Kaplan, David L

    2016-07-01

    There is a critical need for monitoring physiologically relevant, sustainable, human adipose tissues in vitro to gain new insights into metabolic diseases. To support long-term culture, a 3D silk scaffold assisted culture system is developed that maintains mature unilocular adipocytes ex vivo in coculture with preadipocytes, endothelial cells, and smooth muscle cells obtained from small volumes of liquefied adipose samples. Without the silk scaffold, adipose tissue explants cannot be sustained in long-term culture (3 months) due to their fragility. Adjustments to media components are used to tune lipid metabolism and proliferation, in addition to responsiveness to an inflammatory stimulus. Interestingly, patient specific responses to TNFα stimulation are observed, providing a proof-of-concept translational technique for patient specific disease modeling in the future. In summary, this novel 3D scaffold assisted approach is required for establishing physiologically relevant, sustainable, human adipose tissue systems from small volumes of lipoaspirate, making this methodology of great value to studies of metabolism, adipokine-driven diseases, and other diseases where the roles of adipocytes are only now becoming uncovered. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Diffusion anisotropy in fresh and fixed prostate tissue ex vivo.

    PubMed

    Bourne, Roger M; Bongers, Andre; Chatterjee, Aritrick; Sved, Paul; Watson, Geoffrey

    2016-08-01

    To investigate diffusion anisotropy in whole human prostate specimens Seven whole radical prostatectomy specimens were obtained with informed patient consent and institutional ethics approval. Diffusion tensor imaging was performed at 9.4 Tesla. Diffusion tensors were calculated from the native acquired data and after progressive downsampling Fractional anisotropy (FA) decreased as voxel volume increased, and differed widely between prostates. Fixation decreased mean FA by ∼0.05-0.08 at all voxel volumes but did not alter principle eigenvector orientation. In unfixed tissue high FA (> 0.6) was found only in voxels of volume <0.5 mm(3) , and then only in a small fraction of all voxels. At typical clinical voxel volumes (4-16 mm(3) ) less than 50% of voxels had FA > 0.25. FA decreased at longer diffusion times (Δ = 60 or 80 ms compared with 20 ms), but only by ∼0.02 at typical clinical voxel volume. Peripheral zone FA was significantly lower than transition zone FA in five of the seven prostates FA varies widely between prostates. The very small proportion of clinical size voxels with high FA suggests that in clinical DWI studies ADC based on three-direction measurements will be minimally affected by anisotropy. Magn Reson Med 76:626-634, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  1. Functional imaging of small tissue volumes with diffuse optical tomography

    NASA Astrophysics Data System (ADS)

    Klose, Alexander D.; Hielscher, Andreas H.

    2006-03-01

    Imaging of dynamic changes in blood parameters, functional brain imaging, and tumor imaging are the most advanced application areas of diffuse optical tomography (DOT). When dealing with the image reconstruction problem one is faced with the fact that near-infrared photons, unlike X-rays, are highly scattered when they traverse biological tissue. Image reconstruction schemes are required that model the light propagation inside biological tissue and predict measurements on the tissue surface. By iteratively changing the tissue-parameters until the predictions agree with the real measurements, a spatial distribution of optical properties inside the tissue is found. The optical properties can be related to the tissue oxygenation, inflammation, or to the fluorophore concentration of a biochemical marker. If the model of light propagation is inaccurate, the reconstruction process will lead to an inaccurate result as well. Here, we focus on difficulties that are encountered when DOT is employed for functional imaging of small tissue volumes, for example, in cancer studies involving small animals, or human finger joints for early diagnosis of rheumatoid arthritis. Most of the currently employed image reconstruction methods rely on the diffusion theory that is an approximation to the equation of radiative transfer. But, in the cases of small tissue volumes and tissues that contain low scattering regions diffusion theory has been shown to be of limited applicability Therefore, we employ a light propagation model that is based on the equation of radiative transfer, which promises to overcome the limitations.

  2. The effect of intravenous lactated Ringer's solution versus 0.9% sodium chloride solution on serum osmolality in human volunteers.

    PubMed

    Williams, E L; Hildebrand, K L; McCormick, S A; Bedel, M J

    1999-05-01

    Animal studies have shown that large volumes of IV lactated Ringer's solution (LR) decrease serum osmolality, thereby increasing cerebral water. These studies have led to recommendations to limit LR to avoid cerebral edema in neurosurgical patients. Eighteen healthy human volunteers aged 20-48 yr received 50 mL/kg LR over 1 h on one occasion and 0.9% sodium chloride (NS) on another. Venous samples were taken at baseline (T1), at infusion end (T2), and 1 h after T2 (T3). Time until first urination was noted. With LR, serum osmolality decreased by 4+/-3 mOsm/kg from T1 to T2 and increased insignificantly with NS. At T3, osmolality returned almost to baseline in the LR group. Blood pH increased from T1 to T2 with LR by 0.04+/-0.04 and decreased with NS by 0.04+/-0.04. These pH changes persisted at T3. Subjective mental changes occurred only with NS. Abdominal discomfort was more common with NS. Time until first urination was longer with NS (106+/-11 min) than with LR (75+/-10 min) (P < 0.001). In healthy humans, an infusion of large volumes of LR, but not NS, transiently decreased serum osmolality, whereas acidosis associated with NS persisted and urinary output was slower with NS. Large volumes of lactated Ringer's solution administered to healthy humans produced small transient changes in serum osmolality. Large volumes of sodium chloride did not change osmolality but resulted in lower pH.

  3. Wavelet analysis of head acceleration response under dirac excitation for early oedema detection.

    PubMed

    Kostopoulos, V; Loutas, T H; Derdas, C; Douzinas, E

    2008-04-01

    The present work deals with the application of an innovative in-house developed wavelet-based methodology for the analysis of the acceleration responses of a human head complex model as a simulated diffused oedema progresses. The human head complex has been modeled as a structure consisting of three confocal prolate spheroids, whereas the three defined regions by the system of spheroids, from the outside to the inside, represent the scull, the region of cerebrospinal fluid, and the brain tissue. A Dirac-like pulse has been used to excite the human head complex model and the acceleration response of the system has been calculated and analyzed via the wavelet-based methodology. For the purpose of the present analysis, a wave propagation commercial finite element code, LS-DYNA 3D, has been used. The progressive diffused oedema was modeled via consecutive increases in brain volume accompanied by a decrease in brain density. It was shown that even a small increase in brain volume (at the level of 0.5%) can be identified by the effect it has on the vibration characteristics of the human head complex. More precisely, it was found that for some of the wavelet decomposition levels, the energy content changes monotonically as the brain volume increases, thus providing a useful index of monitoring an oncoming brain oedema before any brain damage appears due to uncontrolled intracranial hypertension. For the purpose of the present work and for the levels of brain volume increase considered in the present analysis, no pressure increase was assumed into the cranial vault and, associatively, no brain compliance variation.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xu, C. Shan; Hayworth, Kenneth J.; Lu, Zhiyuan

    Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) can automatically generate 3D images with superior z-axis resolution, yielding data that needs minimal image registration and related post-processing. Obstacles blocking wider adoption of FIB-SEM include slow imaging speed and lack of long-term system stability, which caps the maximum possible acquisition volume. Here, we present techniques that accelerate image acquisition while greatly improving FIB-SEM reliability, allowing the system to operate for months and generating continuously imaged volumes > 10 6 ?m 3 . These volumes are large enough for connectomics, where the excellent z resolution can help in tracing of small neuronal processesmore » and accelerate the tedious and time-consuming human proofreading effort. Even higher resolution can be achieved on smaller volumes. We present example data sets from mammalian neural tissue, Drosophila brain, and Chlamydomonas reinhardtii to illustrate the power of this novel high-resolution technique to address questions in both connectomics and cell biology.« less

  5. Quantitative volumetric imaging of normal, neoplastic and hyperplastic mouse prostate using ultrasound.

    PubMed

    Singh, Shalini; Pan, Chunliu; Wood, Ronald; Yeh, Chiuan-Ren; Yeh, Shuyuan; Sha, Kai; Krolewski, John J; Nastiuk, Kent L

    2015-09-21

    Genetically engineered mouse models are essential to the investigation of the molecular mechanisms underlying human prostate pathology and the effects of therapy on the diseased prostate. Serial in vivo volumetric imaging expands the scope and accuracy of experimental investigations of models of normal prostate physiology, benign prostatic hyperplasia and prostate cancer, which are otherwise limited by the anatomy of the mouse prostate. Moreover, accurate imaging of hyperplastic and tumorigenic prostates is now recognized as essential to rigorous pre-clinical trials of new therapies. Bioluminescent imaging has been widely used to determine prostate tumor size, but is semi-quantitative at best. Magnetic resonance imaging can determine prostate volume very accurately, but is expensive and has low throughput. We therefore sought to develop and implement a high throughput, low cost, and accurate serial imaging protocol for the mouse prostate. We developed a high frequency ultrasound imaging technique employing 3D reconstruction that allows rapid and precise assessment of mouse prostate volume. Wild-type mouse prostates were examined (n = 4) for reproducible baseline imaging, and treatment effects on volume were compared, and blinded data analyzed for intra- and inter-operator assessments of reproducibility by correlation and for Bland-Altman analysis. Examples of benign prostatic hyperplasia mouse model prostate (n = 2) and mouse prostate implantation of orthotopic human prostate cancer tumor and its growth (n =  ) are also demonstrated. Serial measurement volume of the mouse prostate revealed that high frequency ultrasound was very precise. Following endocrine manipulation, regression and regrowth of the prostate could be monitored with very low intra- and interobserver variability. This technique was also valuable to monitor the development of prostate growth in a model of benign prostatic hyperplasia. Additionally, we demonstrate accurate ultrasound image-guided implantation of orthotopic tumor xenografts and monitoring of subsequent tumor growth from ~10 to ~750 mm(3) volume. High frequency ultrasound imaging allows precise determination of normal, neoplastic and hyperplastic mouse prostate. Low cost and small image size allows incorporation of this imaging modality inside clean animal facilities, and thereby imaging of immunocompromised models. 3D reconstruction for volume determination is easily mastered, and both small and large relative changes in volume are accurately visualized. Ultrasound imaging does not rely on penetration of exogenous imaging agents, and so may therefore better measure poorly vascularized or necrotic diseased tissue, relative to bioluminescent imaging (IVIS). Our method is precise and reproducible with very low inter- and intra-observer variability. Because it is non-invasive, mouse models of prostatic disease states can be imaged serially, reducing inter-animal variability, and enhancing the power to detect small volume changes following therapeutic intervention.

  6. Enhanced FIB-SEM systems for large-volume 3D imaging

    PubMed Central

    Xu, C Shan; Hayworth, Kenneth J; Lu, Zhiyuan; Grob, Patricia; Hassan, Ahmed M; García-Cerdán, José G; Niyogi, Krishna K; Nogales, Eva; Weinberg, Richard J; Hess, Harald F

    2017-01-01

    Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) can automatically generate 3D images with superior z-axis resolution, yielding data that needs minimal image registration and related post-processing. Obstacles blocking wider adoption of FIB-SEM include slow imaging speed and lack of long-term system stability, which caps the maximum possible acquisition volume. Here, we present techniques that accelerate image acquisition while greatly improving FIB-SEM reliability, allowing the system to operate for months and generating continuously imaged volumes > 106 µm3. These volumes are large enough for connectomics, where the excellent z resolution can help in tracing of small neuronal processes and accelerate the tedious and time-consuming human proofreading effort. Even higher resolution can be achieved on smaller volumes. We present example data sets from mammalian neural tissue, Drosophila brain, and Chlamydomonas reinhardtii to illustrate the power of this novel high-resolution technique to address questions in both connectomics and cell biology. DOI: http://dx.doi.org/10.7554/eLife.25916.001 PMID:28500755

  7. Enhanced FIB-SEM systems for large-volume 3D imaging

    DOE PAGES

    Xu, C. Shan; Hayworth, Kenneth J.; Lu, Zhiyuan; ...

    2017-05-13

    Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) can automatically generate 3D images with superior z-axis resolution, yielding data that needs minimal image registration and related post-processing. Obstacles blocking wider adoption of FIB-SEM include slow imaging speed and lack of long-term system stability, which caps the maximum possible acquisition volume. Here, we present techniques that accelerate image acquisition while greatly improving FIB-SEM reliability, allowing the system to operate for months and generating continuously imaged volumes > 10 6 ?m 3 . These volumes are large enough for connectomics, where the excellent z resolution can help in tracing of small neuronal processesmore » and accelerate the tedious and time-consuming human proofreading effort. Even higher resolution can be achieved on smaller volumes. We present example data sets from mammalian neural tissue, Drosophila brain, and Chlamydomonas reinhardtii to illustrate the power of this novel high-resolution technique to address questions in both connectomics and cell biology.« less

  8. Childhood-Onset Asthma in Smokers. Association between CT Measures of Airway Size, Lung Function, and Chronic Airflow Obstruction

    PubMed Central

    Hardin, Megan E.; Come, Carolyn E.; San José Estépar, Raúl; Ross, James C.; Kurugol, Sila; Okajima, Yuka; Han, MeiLan K.; Kim, Victor; Ramsdell, Joe; Silverman, Edwin K.; Crapo, James D.; Lynch, David A.; Make, Barry; Barr, R. Graham; Hersh, Craig P.; Washko, George R.

    2014-01-01

    Rationale and Objectives: Asthma is associated with chronic airflow obstruction. Our goal was to assess the association of computed tomographic measures of airway wall volume and lumen volume with the FEV1 and chronic airflow obstruction in smokers with childhood-onset asthma. Methods: We analyzed clinical, lung function, and volumetric computed tomographic airway volume data from 7,266 smokers, including 590 with childhood-onset asthma. Small wall volume and small lumen volume of segmental airways were defined as measures 1 SD below the mean. We assessed the association between small wall volume, small lumen volume, FEV1, and chronic airflow obstruction (post-bronchodilator FEV1/FVC ratio < 0.7) using linear and logistic models. Measurements and Main Results: Compared with subjects without childhood-onset asthma, those with childhood-onset asthma had smaller wall volume and lumen volume (P < 0.0001) of segmental airways. Among subjects with childhood-onset asthma, those with the smallest wall volume and lumen volume had the lowest FEV1 and greatest odds of chronic airflow obstruction. A similar tendency was seen in those without childhood-onset asthma. When comparing these two groups, both small wall volume and small lumen volume were more strongly associated with FEV1 and chronic airflow obstruction among subjects with childhood-asthma in multivariate models. Conclusion: In smokers with childhood-onset asthma, smaller airways are associated with reduced lung function and chronic airflow obstruction. Clinical trial registered with www.clinicaltrials.gov (NCT00608764). PMID:25296268

  9. Childhood-onset asthma in smokers. association between CT measures of airway size, lung function, and chronic airflow obstruction.

    PubMed

    Diaz, Alejandro A; Hardin, Megan E; Come, Carolyn E; San José Estépar, Raúl; Ross, James C; Kurugol, Sila; Okajima, Yuka; Han, MeiLan K; Kim, Victor; Ramsdell, Joe; Silverman, Edwin K; Crapo, James D; Lynch, David A; Make, Barry; Barr, R Graham; Hersh, Craig P; Washko, George R

    2014-11-01

    Asthma is associated with chronic airflow obstruction. Our goal was to assess the association of computed tomographic measures of airway wall volume and lumen volume with the FEV1 and chronic airflow obstruction in smokers with childhood-onset asthma. We analyzed clinical, lung function, and volumetric computed tomographic airway volume data from 7,266 smokers, including 590 with childhood-onset asthma. Small wall volume and small lumen volume of segmental airways were defined as measures 1 SD below the mean. We assessed the association between small wall volume, small lumen volume, FEV1, and chronic airflow obstruction (post-bronchodilator FEV1/FVC ratio < 0.7) using linear and logistic models. Compared with subjects without childhood-onset asthma, those with childhood-onset asthma had smaller wall volume and lumen volume (P < 0.0001) of segmental airways. Among subjects with childhood-onset asthma, those with the smallest wall volume and lumen volume had the lowest FEV1 and greatest odds of chronic airflow obstruction. A similar tendency was seen in those without childhood-onset asthma. When comparing these two groups, both small wall volume and small lumen volume were more strongly associated with FEV1 and chronic airflow obstruction among subjects with childhood-asthma in multivariate models. In smokers with childhood-onset asthma, smaller airways are associated with reduced lung function and chronic airflow obstruction. Clinical trial registered with www.clinicaltrials.gov (NCT00608764).

  10. Ultrasonographic study of mechanosensory properties in human esophagus during mechanical distension

    PubMed Central

    Larsen, Ejnar; Reddy, Hariprasad; Drewes, Asbjørn Mohr; Arendt-Nielsen, Lars; Gregersen, Hans

    2006-01-01

    AIM: To study the esophageal geometry and mechanosensation using endoscopic ultrasonography during volume-controlled ramp distensions in the distal esophagus. METHODS: Twelve healthy volunteers underwent distension of a bag. During distension up to moderate pain the sensory intensity was assessed on a visual analogue scale (VAS). The esophageal deformation in terms of multidimensional stretch ratios and strains was calculated at different volumes and VAS levels. Distensions were done before and during administration of the anti-cholinergic drug butylscopolamine. RESULTS: The stimulus-response (volume-VAS) curve did not differ without or with the administration of butylscopolamine. Analysis of stretch ratios demonstrated tensile stretch in circumferential direction, compression in radial direction and a small tensile stretch in longitudinal direction. A strain gradient existed throughout the esophageal wall with the largest circumferential deformation at the mucosal surface. The sensation intensity increased exponentially as function of the strains. CONCLUSION: The method provides information of esophageal deformation gradients that correlate to the sensation intensity. Hence, it can be used to study mechanosensation in the human esophagus. Further studies are needed to determine the exact deformation stimulus for the esophageal mechanoreceptors. PMID:16874864

  11. 2006 In Vitro Biology Meeting. Volume 42

    DTIC Science & Technology

    2006-04-25

    industry. Production of elite stock plants for small fruit and vegetable crops is a secondary area of activity . Clonal propagation of coniferous forest...Biotechnology, Inc. 11:45 P-18 Transgenic Expression and Recovery of Biologically Active Recombinant Human Insulin from Arabidopsis thaliana Oilseeds...Mangadlao, University of the Philippines SECONDARY PRODUCTS AND BIOTECHNOLOGY Moderator: Mitchell L. Wise, USDA/ARS 2:30 pm - 3:30 pm Plant Interactive

  12. Meta-analysis reveals a lack of sexual dimorphism in human amygdala volume.

    PubMed

    Marwha, Dhruv; Halari, Meha; Eliot, Lise

    2017-02-15

    The amygdala plays a key role in many affective behaviors and psychiatric disorders that differ between men and women. To test whether human amygdala volume (AV) differs reliably between the sexes, we performed a systematic review and meta-analysis of AVs reported in MRI studies of age-matched healthy male and female groups. Using four search strategies, we identified 46 total studies (58 matched samples) from which we extracted effect sizes for the sex difference in AV. All data were converted to Hedges g values and pooled effect sizes were calculated using a random-effects model. Each dataset was further meta-regressed against study year and average participant age. We found that uncorrected amygdala volume is about 10% larger in males, with pooled sex difference effect sizes of g=0.581 for right amygdala (κ=28, n=2022), 0.666 for left amygdala (κ=28, n=2006), and 0.876 for bilateral amygdala (κ=16, n=1585) volumes (all p values < 0.001). However, this difference is comparable to the sex differences in intracranial volume (ICV; g=1.186, p<.001, 11.9% larger in males, κ=11) and total brain volume (TBV; g=1.278, p<0.001, 11.5% larger in males, κ=15) reported in subsets of the same studies, suggesting the sex difference in AV is a product of larger brain size in males. Among studies reporting AVs normalized for ICV or TBV, sex difference effect sizes were small and not statistically significant: g=0.171 for the right amygdala (p=0.206, κ=13, n=1560); 0.233 for the left amygdala (p=0.092, κ=12, n=1512); and 0.257 for bilateral volume (p=0.131, κ=5, n=1629). These values correspond to less than 0.1% larger corrected right AV and 2.5% larger corrected left AV in males compared to females. In summary, AV is not selectively enhanced in human males, as often claimed. Although we cannot rule out subtle male-female group differences, it is not accurate to refer to the human amygdala as "sexually dimorphic." Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Respiratory Mucosal Proteome Quantification in Human Influenza Infections.

    PubMed

    Marion, Tony; Elbahesh, Husni; Thomas, Paul G; DeVincenzo, John P; Webby, Richard; Schughart, Klaus

    2016-01-01

    Respiratory influenza virus infections represent a serious threat to human health. Underlying medical conditions and genetic make-up predispose some influenza patients to more severe forms of disease. To date, only a few studies have been performed in patients to correlate a selected group of cytokines and chemokines with influenza infection. Therefore, we evaluated the potential of a novel multiplex micro-proteomics technology, SOMAscan, to quantify proteins in the respiratory mucosa of influenza A and B infected individuals. The analysis included but was not limited to quantification of cytokines and chemokines detected in previous studies. SOMAscan quantified more than 1,000 secreted proteins in small nasal wash volumes from infected and healthy individuals. Our results illustrate the utility of micro-proteomic technology for analysis of proteins in small volumes of respiratory mucosal samples. Furthermore, when we compared nasal wash samples from influenza-infected patients with viral load ≥ 2(8) and increased IL-6 and CXCL10 to healthy controls, we identified 162 differentially-expressed proteins between the two groups. This number greatly exceeds the number of DEPs identified in previous studies in human influenza patients. Most of the identified proteins were associated with the host immune response to infection, and changes in protein levels of 151 of the DEPs were significantly correlated with viral load. Most important, SOMAscan identified differentially expressed proteins heretofore not associated with respiratory influenza infection in humans. Our study is the first report for the use of SOMAscan to screen nasal secretions. It establishes a precedent for micro-proteomic quantification of proteins that reflect ongoing response to respiratory infection.

  14. Respiratory Mucosal Proteome Quantification in Human Influenza Infections

    PubMed Central

    Marion, Tony; Elbahesh, Husni; Thomas, Paul G.; DeVincenzo, John P.; Webby, Richard; Schughart, Klaus

    2016-01-01

    Respiratory influenza virus infections represent a serious threat to human health. Underlying medical conditions and genetic make-up predispose some influenza patients to more severe forms of disease. To date, only a few studies have been performed in patients to correlate a selected group of cytokines and chemokines with influenza infection. Therefore, we evaluated the potential of a novel multiplex micro-proteomics technology, SOMAscan, to quantify proteins in the respiratory mucosa of influenza A and B infected individuals. The analysis included but was not limited to quantification of cytokines and chemokines detected in previous studies. SOMAscan quantified more than 1,000 secreted proteins in small nasal wash volumes from infected and healthy individuals. Our results illustrate the utility of micro-proteomic technology for analysis of proteins in small volumes of respiratory mucosal samples. Furthermore, when we compared nasal wash samples from influenza-infected patients with viral load ≥ 28 and increased IL-6 and CXCL10 to healthy controls, we identified 162 differentially-expressed proteins between the two groups. This number greatly exceeds the number of DEPs identified in previous studies in human influenza patients. Most of the identified proteins were associated with the host immune response to infection, and changes in protein levels of 151 of the DEPs were significantly correlated with viral load. Most important, SOMAscan identified differentially expressed proteins heretofore not associated with respiratory influenza infection in humans. Our study is the first report for the use of SOMAscan to screen nasal secretions. It establishes a precedent for micro-proteomic quantification of proteins that reflect ongoing response to respiratory infection. PMID:27088501

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knudsen, Gabriel A., E-mail: gabriel.knudsen@nih.gov; Hughes, Michael F.; McIntosh, Katelyn L.

    Tetrabromobisphenol A (TBBPA) is currently the world's highest production volume brominated flame retardant. Humans are frequently exposed to TBBPA by the dermal route. In the present study, a parallelogram approach was used to make predictions of internal dose in exposed humans. Human and rat skin samples received 100 nmol of TBBPA/cm{sup 2} skin and absorption and penetrance were determined using a flow-through in vitro system. TBBPA-derived [{sup 14}C]-radioactivity was determined at 6 h intervals in the media and at 24 h post-dosing in the skin. The human skin and media contained an average of 3.4% and 0.2% of the totalmore » dose at the terminal time point, respectively, while the rat skin and media contained 9.3% and 3.5%, respectively. In the intact rat, 14% of a dermally-administered dose of ~ 100 nmol/cm{sup 2} remained in the skin at the dosing site, with an additional 8% reaching systemic circulation by 24 h post-dosing. Relative absorption and penetrance were less (10% total) at 24 h following dermal administration of a ten-fold higher dose (~ 1000 nmol/cm{sup 2}) to rats. However, by 72 h, 70% of this dose was either absorbed into the dosing-site skin or had reached systemic circulation. It is clear from these results that TBBPA can be absorbed by the skin and dermal contact with TBBPA may represent a small but important route of exposure. Together, these in vitro data in human and rat skin and in vivo data from rats may be used to predict TBBPA absorption in humans following dermal exposure. Based on this parallelogram calculation, up to 6% of dermally applied TBBPA may be bioavailable to humans exposed to TBBPA. - Highlights: • Tetrabromobisphenol A is the brominated flame retardant with highest global production volumes. • Humans are frequently exposed to TBBPA by the dermal route, especially via contaminated dust. • Human and rat skin data were integrated using a parallelogram method to predict human absorption. • TBBPA was dermally absorbed and skin contact may represent a small but important route of exposure. • Up to 6% of dermally applied TBBPA may be bioavailable to humans exposed to TBBPA.« less

  16. 40 CFR 1051.635 - What provisions apply to new manufacturers that are small businesses?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Act. For example, we may place sales limits on companies that we designate to be small-volume....201) that manufactures recreational vehicles, but does not otherwise qualify for the small-volume manufacturer provisions of this part, you may ask us to designate you to be a small-volume manufacturer. You...

  17. 40 CFR 80.1622 - Approval for small refiner and small volume refinery status.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... appropriate data to correct the record when the company submits its application. (ii) Foreign small refiners... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Approval for small refiner and small... Approval for small refiner and small volume refinery status. (a) Applications for small refiner or small...

  18. Designing a dynamic dissolution method: a review of instrumental options and corresponding physiology of stomach and small intestine.

    PubMed

    Culen, Martin; Rezacova, Anna; Jampilek, Josef; Dohnal, Jiri

    2013-09-01

    Development of new pharmaceutical compounds and dosage forms often requires in vitro dissolution testing with the closest similarity to the human gastrointestinal (GI) tract. To create such conditions, one needs a suitable dissolution apparatus and the appropriate data on the human GI physiology. This review discusses technological approaches applicable in biorelevant dissolutions as well as the physiology of stomach and small intestine in both fasted and fed state, that is, volumes of contents, transit times for water/food and various solid oral dosage forms, pH, osmolality, surface tension, buffer capacity, and concentrations of bile salts, phospholipids, enzymes, and Ca(2+) ions. The information is aimed to provide clear suggestions on how these conditions should be set in a dynamic biorelevant dissolution test. Copyright © 2013 Wiley Periodicals, Inc.

  19. Reproducibility of myelin content-based human habenula segmentation at 3 Tesla.

    PubMed

    Kim, Joo-Won; Naidich, Thomas P; Joseph, Joshmi; Nair, Divya; Glasser, Matthew F; O'halloran, Rafael; Doucet, Gaelle E; Lee, Won Hee; Krinsky, Hannah; Paulino, Alejandro; Glahn, David C; Anticevic, Alan; Frangou, Sophia; Xu, Junqian

    2018-03-26

    In vivo morphological study of the human habenula, a pair of small epithalamic nuclei adjacent to the dorsomedial thalamus, has recently gained significant interest for its role in reward and aversion processing. However, segmenting the habenula from in vivo magnetic resonance imaging (MRI) is challenging due to the habenula's small size and low anatomical contrast. Although manual and semi-automated habenula segmentation methods have been reported, the test-retest reproducibility of the segmented habenula volume and the consistency of the boundaries of habenula segmentation have not been investigated. In this study, we evaluated the intra- and inter-site reproducibility of in vivo human habenula segmentation from 3T MRI (0.7-0.8 mm isotropic resolution) using our previously proposed semi-automated myelin contrast-based method and its fully-automated version, as well as a previously published manual geometry-based method. The habenula segmentation using our semi-automated method showed consistent boundary definition (high Dice coefficient, low mean distance, and moderate Hausdorff distance) and reproducible volume measurement (low coefficient of variation). Furthermore, the habenula boundary in our semi-automated segmentation from 3T MRI agreed well with that in the manual segmentation from 7T MRI (0.5 mm isotropic resolution) of the same subjects. Overall, our proposed semi-automated habenula segmentation showed reliable and reproducible habenula localization, while its fully-automated version offers an efficient way for large sample analysis. © 2018 Wiley Periodicals, Inc.

  20. Microvascular basis for growth of small infarcts following occlusion of single penetrating arterioles in mouse cortex

    PubMed Central

    Taylor, Zachary J; Hui, Edward S; Watson, Ashley N; Nie, Xingju; Deardorff, Rachael L; Jensen, Jens H; Helpern, Joseph A

    2015-01-01

    Small cerebral infarcts, i.e. microinfarcts, are common in the aging brain and linked to vascular cognitive impairment. However, little is known about the acute growth of these minute lesions and their effect on blood flow in surrounding tissues. We modeled microinfarcts in the mouse cortex by inducing photothrombotic clots in single penetrating arterioles. The resultant hemodynamic changes in tissues surrounding the occluded vessel were then studied using in vivo two-photon microscopy. We were able to generate a spectrum of infarct volumes by occluding arterioles that carried a range of blood fluxes. Those resulting from occlusion of high-flux penetrating arterioles (flux of 2 nL/s or higher) exhibited a radial outgrowth that encompassed unusually large tissue volumes. The gradual expansion of these infarcts was propagated by an evolving insufficiency in capillary flow that encroached on territories of neighboring penetrating arterioles, leading to the stagnation and recruitment of their perfusion domains into the final infarct volume. Our results suggest that local collapse of microvascular function contributes to tissue damage incurred by single penetrating arteriole occlusions in mice, and that a similar mechanism may add to pathophysiology induced by microinfarcts of the human brain. PMID:26661182

  1. An Introductory Description of the ILLIAC IV System. Volume 1

    DTIC Science & Technology

    1971-07-15

    Difference Engine and Analytical Engine ■’’.! a. The Difference Engine M In 1812, when Charles Babbage was an undergraduate at Trinity- College...numbers, thus eliminating the possibility of a human transcription error. Babbage fabricated a small Difference Engine which could tabu- late a...decimal digits. His ambitious project was never com- pleted. Work stopped in 1833 when Babbage ran into financial difficulties with his engineer who

  2. Building an experimental model of the human body with non-physiological parameters.

    PubMed

    Labuz, Joseph M; Moraes, Christopher; Mertz, David R; Leung, Brendan M; Takayama, Shuichi

    2017-03-01

    New advances in engineering and biomedical technology have enabled recent efforts to capture essential aspects of human physiology in microscale, in-vitro systems. The application of these advances to experimentally model complex processes in an integrated platform - commonly called a 'human-on-a-chip (HOC)' - requires that relevant compartments and parameters be sized correctly relative to each other and to the system as a whole. Empirical observation, theoretical treatments of resource distribution systems and natural experiments can all be used to inform rational design of such a system, but technical and fundamental challenges (e.g. small system blood volumes and context-dependent cell metabolism, respectively) pose substantial, unaddressed obstacles. Here, we put forth two fundamental principles for HOC design: inducing in-vivo -like cellular metabolic rates is necessary and may be accomplished in-vitro by limiting O 2 availability and that the effects of increased blood volumes on drug concentration can be mitigated through pharmacokinetics-based treatments of solute distribution. Combining these principles with natural observation and engineering workarounds, we derive a complete set of design criteria for a practically realizable, physiologically faithful, five-organ millionth-scale (× 10 -6 ) microfluidic model of the human body.

  3. Building an experimental model of the human body with non-physiological parameters

    PubMed Central

    Labuz, Joseph M.; Moraes, Christopher; Mertz, David R.; Leung, Brendan M.; Takayama, Shuichi

    2017-01-01

    New advances in engineering and biomedical technology have enabled recent efforts to capture essential aspects of human physiology in microscale, in-vitro systems. The application of these advances to experimentally model complex processes in an integrated platform — commonly called a ‘human-on-a-chip (HOC)’ — requires that relevant compartments and parameters be sized correctly relative to each other and to the system as a whole. Empirical observation, theoretical treatments of resource distribution systems and natural experiments can all be used to inform rational design of such a system, but technical and fundamental challenges (e.g. small system blood volumes and context-dependent cell metabolism, respectively) pose substantial, unaddressed obstacles. Here, we put forth two fundamental principles for HOC design: inducing in-vivo-like cellular metabolic rates is necessary and may be accomplished in-vitro by limiting O2 availability and that the effects of increased blood volumes on drug concentration can be mitigated through pharmacokinetics-based treatments of solute distribution. Combining these principles with natural observation and engineering workarounds, we derive a complete set of design criteria for a practically realizable, physiologically faithful, five-organ millionth-scale (× 10−6) microfluidic model of the human body. PMID:28713851

  4. Biomonitoring of perfluorinated compounds in a drop of blood.

    PubMed

    Mao, Pan; Wang, Daojing

    2015-06-02

    Biomonitoring of pollutants and their metabolites and derivatives using biofluids provides new opportunities for spatiotemporal assessment of human risks to environmental exposures. Perfluorinated compounds (PFCs) have been used widely in industry and pose significant environmental concerns due to their stability and bioaccumulation in humans and animals. However, current methods for extraction and measurement of PFCs require relatively large volumes (over one hundred microliters) of blood samples, and therefore, are not suitable for frequent blood sampling and longitudinal biomonitoring of PFCs. We have developed a new microassay, enabled by our silicon microfluidic chip platform, for analyzing PFCs in small volumes (less than five microliters) of blood. Our assay integrates on-chip solid-phase extraction (SPE) with online nanoflow liquid chromatography-electrospray ionization-mass spectrometry (nanoLC-ESI-MS) detection. We demonstrated high sample recovery, excellent interday and intraday accuracy and precision, and a limit of detection down to 50 femtogram of PFCs, in one microliter of human plasma. We validated our assay performance using pooled human plasma and NIST SRM 1950 samples. Our microfluidic chip-based assay may enable frequent longitudinal biomonitoring of PFCs and other environmental toxins using a finger prick of blood, thereby providing new insights into their bioaccumulation, bioavailability, and toxicity.

  5. Lung Morphometry with Hyperpolarized 129Xe: Theoretical Background

    PubMed Central

    Sukstanskii, A.L.; Yablonskiy, D.A.

    2011-01-01

    The 3He lung morphometry technique, based on MRI measurements of hyperpolarized 3He gas diffusion in lung airspaces, provides unique information on the lung microstructure at the alveolar level. In vivo 3D tomographic images of standard morphological parameters (airspace chord length, lung parenchyma surface-to-volume ratio, number of alveoli per unit volume) can be generated from a rather short (several seconds) MRI scan. The technique is based on a theory of gas diffusion in lung acinar airways and experimental measurements of diffusion attenuated MRI signal. The present work aims at developing the theoretical background of a similar technique based on hyperpolarized 129Xe gas. As the diffusion coefficient and gyromagnetic ratio of 129Xe gas are substantially different from those of 3He gas, the specific details of the theory and experimental measurements with 129Xe should be amended. We establish phenomenological relationships between acinar airway geometrical parameters and the diffusion attenuated MR signal for human and small animal lungs, both normal lungs and lungs with mild emphysema. Optimal diffusion times are shown to be about 5 ms for human and 1.3 ms for small animals. The expected uncertainties in measuring main morphometrical parameters of the lungs are estimated in the framework of Bayesian probability theory. PMID:21713985

  6. Ultrahigh-definition dynamic 3D holographic display by active control of volume speckle fields

    NASA Astrophysics Data System (ADS)

    Yu, Hyeonseung; Lee, Kyeoreh; Park, Jongchan; Park, Yongkeun

    2017-01-01

    Holographic displays generate realistic 3D images that can be viewed without the need for any visual aids. They operate by generating carefully tailored light fields that replicate how humans see an actual environment. However, the realization of high-performance, dynamic 3D holographic displays has been hindered by the capabilities of present wavefront modulator technology. In particular, spatial light modulators have a small diffraction angle range and limited pixel number limiting the viewing angle and image size of a holographic 3D display. Here, we present an alternative method to generate dynamic 3D images by controlling volume speckle fields significantly enhancing image definition. We use this approach to demonstrate a dynamic display of micrometre-sized optical foci in a volume of 8 mm × 8 mm × 20 mm.

  7. Bioavailability of Tetracycline and Doxycycline in Fasted and Nonfasted Subjects

    PubMed Central

    Welling, Peter G.; Koch, Patricia A.; Lau, Curtis C.; Craig, William A.

    1977-01-01

    The influence of various test meals and fluid volumes on the relative bioavailability of commercial formulations of doxycycline hyclate and tetracycline hydrochloride was studied in healthy human volunteers. Serum levels of tetracycline were uniformly reduced by approximately 50% by all test meals, whereas serum levels of doxycycline were reduced by 20%. The reduction of tetracycline serum levels will likely be of clinical significance. The bioavailability of each drug was almost identical from an oral solution and from capsules in fasted subjects. The rate of doxycycline absorption was reduced when capsules were administered with a small volume of water, but the overall efficiency of absorption of both drugs was essentially independent of co-administered fluid volume. The use of 8-h serum data provides a reliable estimate of drug bioavailability for tetracycline and, to a lesser extent, for doxycycline. PMID:856000

  8. Automated Propulsion Data Screening demonstration system

    NASA Technical Reports Server (NTRS)

    Hoyt, W. Andes; Choate, Timothy D.; Whitehead, Bruce A.

    1995-01-01

    A fully-instrumented firing of a propulsion system typically generates a very large quantity of data. In the case of the Space Shuttle Main Engine (SSME), data analysis from ground tests and flights is currently a labor-intensive process. Human experts spend a great deal of time examining the large volume of sensor data generated by each engine firing. These experts look for any anomalies in the data which might indicate engine conditions warranting further investigation. The contract effort was to develop a 'first-cut' screening system for application to SSME engine firings that would identify the relatively small volume of data which is unusual or anomalous in some way. With such a system, limited and expensive human resources could focus on this small volume of unusual data for thorough analysis. The overall project objective was to develop a fully operational Automated Propulsion Data Screening (APDS) system with the capability of detecting significant trends and anomalies in transient and steady-state data. However, the effort limited screening of transient data to ground test data for throttle-down cases typical of the 3-g acceleration, and for engine throttling required to reach the maximum dynamic pressure limits imposed on the Space Shuttle. This APDS is based on neural networks designed to detect anomalies in propulsion system data that are not part of the data used for neural network training. The delivered system allows engineers to build their own screening sets for application to completed or planned firings of the SSME. ERC developers also built some generic screening sets that NASA engineers could apply immediately to their data analysis efforts.

  9. [Establishment of a 3D finite element model of human skull using MSCT images and mimics software].

    PubMed

    Huang, Ping; Li, Zheng-dong; Shao, Yu; Zou, Dong-hua; Liu, Ning-guo; Li, Li; Chen, Yuan-yuan; Wan, Lei; Chen, Yi-jiu

    2011-02-01

    To establish a human 3D finite element skull model, and to explore its value in biomechanics analysis. The cadaveric head was scanned and then 3D skull model was created using Mimics software based on 2D CT axial images. The 3D skull model was optimized by preprocessor along with creation of the surface and volume meshes. The stress changes, after the head was struck by an object or the head hit the ground directly, were analyzed using ANSYS software. The original 3D skull model showed a large number of triangles with a poor quality and high similarity with the real head, while the optimized model showed high quality surface and volume meshes with a small number of triangles comparatively. The model could show the local and global stress changes effectively. The human 3D skull model can be established using MSCT and Mimics software and provides a good finite element model for biomechanics analysis. This model may also provide a base for the study of head stress changes following different forces.

  10. The Effect of Prism Orientation in the Indentation Testing of Human Molar Enamel

    PubMed Central

    Braly, A.; Darnell, L.A.; Mann, A.B.; Teaford, M.F.; Weihs, T.P.

    2007-01-01

    Recent nanoindentation studies have demonstrated that the hardness and Young's modulus of human molar enamel decreases by more than 50% on moving from the occlusal surface to the dentin-enamel junction on cross-sectional samples. Possible sources of these variations are changes in local chemistry, microstructure, and prism orientation. This study investigates the latter source by performing nanoindentation tests at two different orientations relative to the hydroxyapatite prisms: parallel and perpendicular. A single sample volume was tested in order to maintain a constant chemistry and microstructure. The resulting data show very small differences between the two orientations for both hardness and Young's modulus. The 1.5 to 3.0% difference is significantly less than the standard deviations found within the data set. Thus, the variations in hardness and Young's modulus on cross-sectional samples of human molar are attributed to changes in local chemistry (varying levels of mineralization, organic matter, and water content) and changes in microstructure (varying volume fractions of inorganic crystals and organic matrix). The impact of prism orientation on mechanical properties measured by nanoindentation appears to be minimal. PMID:17449008

  11. Prediction of Packed Cell Volume after Whole Blood Transfusion in Small Ruminants and South American Camelids: 80 Cases (2006-2016).

    PubMed

    Luethy, D; Stefanovski, D; Salber, R; Sweeney, R W

    2017-11-01

    Calculation of desired whole blood transfusion volume relies on an estimate of an animal's circulating blood volume, generally accepted to be 0.08 L/kg or 8% of the animal's body weight in kilograms. To use packed cell volume before and after whole blood transfusion to evaluate the accuracy of a commonly used equation to predict packed cell volume after transfusion in small ruminants and South American camelids; to determine the nature and frequency of adverse transfusion reactions in small ruminants and camelids after whole blood transfusion. Fifty-eight small ruminants and 22 alpacas that received whole blood transfusions for anemia. Retrospective case series; medical record review for small ruminants and camelids that received whole blood transfusions during hospitalization. Mean volume of distribution of blood as a fraction of body weight in sheep (0.075 L/kg, 7.5% BW) and goats (0.076 L/kg, 7.6% BW) differed significantly (P < 0.01) from alpacas (0.103 L/kg, 10.3% BW). Mild transfusion reactions were noted in 16% of transfusions. The generally accepted value of 8% for circulating blood volume (volume of distribution of blood) is adequate for calculation of transfusion volumes; however, use of the species-specific circulating blood volume can improve calculation of transfusion volume to predict and achieve desired packed cell volume. The incidence of transfusion reactions in small ruminants and camelids is low. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  12. 31P NMR spectroscopy studies of phospholipid metabolism in human melanoma xenograft lines differing in rate of tumour cell proliferation.

    PubMed

    Lyng, H; Olsen, D R; Petersen, S B; Rofstad, E K

    1995-04-01

    The concentration of phospholipid metabolites in tumours has been hypothesized to be related to rate of cell membrane turnover and may reflect rate of cell proliferation. The purpose of the study reported here was to investigate whether 31P NMR resonance ratios involving the phosphomonoester (PME) or phosphodiester (PDE) resonance are correlated to fraction of cells in S-phase or volume-doubling time in experimental tumours. Four human melanoma xenograft lines (BEX-t, HUX-t, SAX-t, WIX-t) were included in the study. The tumours were grown subcutaneously in male BALB/c-nu/nu mice. 31P NMR spectroscopy was performed at a magnetic field strength of 4.7 T. Fraction of cells in S-phase was measured by flow cytometry. Tumour volume-doubling time was determined by Gompertzian analysis of volumetric growth data. BEX-t and SAX-t tumours differed in fraction of cells in S-phase and volume-doubling time, but showed similar 31P NMR resonance ratios. BEX-t and WIX-t tumours showed significantly different 31P NMR resonance ratios but similar fractions of cells in S-phase. The 31P NMR resonance ratios were significantly different for small and large HUX-t tumours even though fraction of cells in S-phase and volume-doubling time did not differ with tumour volume. None of the 31P NMR resonance ratios showed significant increase with increasing fraction of cells in S-phase or significant decrease with increasing tumour volume-doubling time across the four xenograft lines.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. Red Blood Cell Mechanical Fragility Test for Clinical Research Applications.

    PubMed

    Ziegler, Luke A; Olia, Salim E; Kameneva, Marina V

    2017-07-01

    Red blood cell (RBC) susceptibility to mechanically induced hemolysis, or RBC mechanical fragility (MF), is an important parameter in the characterization of erythrocyte membrane health. The rocker bead test (RBT) and associated calculated mechanical fragility index (MFI) is a simple method for the assessment of RBC MF. Requiring a minimum of 15.5 mL of blood and necessitating adjustment of hematocrit (Ht) to a "standard" value (40%), the current RBT is not suitable for use in most studies involving human subjects. To address these limitations, we propose a 6.5 mL reduced volume RBT and corresponding modified MFI (MMFI) that does not require prior Ht adjustment. This new method was assessed for i) correlation to the existing text, ii) to quantify the effect of Ht on MFI, and iii) validation by reexamining the protective effect of plasma proteins on RBC MF. The reduced volume RBT strongly correlated (r = 0.941) with the established large volume RBT at matched Hts, and an equation was developed to calculate MMFI: a numerical estimation (R 2  = 0.923) of MFI if performed with the reduced volume RBT at "standard" (40%) Ht. An inversely proportional relationship was found between plasma protein concentration and RBC MF using the MMFI-reduced volume method, supporting previous literature findings. The new reduced volume RBT and modified MFI will allow for the measurement of RBC MF in clinical and preclinical studies involving humans or small animals. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  14. Transpleural ventilation of explanted human lungs

    PubMed Central

    Choong, Cliff K; Macklem, Peter T; Pierce, John A; Lefrak, Stephen S; Woods, Jason C; Conradi, Mark S; Yablonskiy, Dimitry A; Hogg, James C; Chino, Kimiaki; Cooper, Joel D

    2007-01-01

    Background The hypothesis that ventilation of emphysematous lungs would be enhanced by communication with the parenchyma through holes in the pleural surface was tested. Methods Fresh human lungs were obtained from patients with emphysema undergoing lung transplantation. Control human lungs were obtained from organ donors whose lungs, for technical reasons, were not considered suitable for implantation. Lungs were ventilated through the bronchial tree or transpleurally via a small hole communicating with the underlying parenchyma over which a flanged silicone tube had been cemented to the surface of the lung (spiracle). Measurements included flow‐volume‐time curves during passive deflation via each pathway; volume of trapped gas recovered from lungs via spiracles when no additional gas was obtainable passively from the airways; and magnetic resonance imaging assessment of spatial distribution of hyperpolarised helium (3He) administered through either the airways or spiracles. Results In emphysematous lungs, passively expelled volumes at 20 s were 94% greater through spiracles than via the airways. Following passive deflation from the airways, an average of 1.07 litres of trapped gas volume was recoverable via spiracles. Regions were ventilated by spiracles that were less well ventilated via bronchi. Conclusions Because of the extensive collateral ventilation present in emphysematous lungs, direct communication with the lung parenchyma through non‐anatomical pathways has the potential to improve the mechanics of breathing and hence ventilation. PMID:17412776

  15. CrossTalk. The Journal of Defense Software Engineering. Volume 13, Number 6, June 2000

    DTIC Science & Technology

    2000-06-01

    Techniques for Efficiently Generating and Testing Software This paper presents a proven process that uses advanced tools to design, develop and test... optimal software. by Keith R. Wegner Large Software Systems—Back to Basics Development methods that work on small problems seem to not scale well to...Ability Requirements for Teamwork: Implications for Human Resource Management, Journal of Management, Vol. 20, No. 2, 1994. 11. Ferguson, Pat, Watts S

  16. Big Data in Science and Healthcare: A Review of Recent Literature and Perspectives

    PubMed Central

    Miron-Shatz, T.; Lau, A. Y. S.; Paton, C.

    2014-01-01

    Summary Objectives As technology continues to evolve and rise in various industries, such as healthcare, science, education, and gaming, a sophisticated concept known as Big Data is surfacing. The concept of analytics aims to understand data. We set out to portray and discuss perspectives of the evolving use of Big Data in science and healthcare and, to examine some of the opportunities and challenges. Methods A literature review was conducted to highlight the implications associated with the use of Big Data in scientific research and healthcare innovations, both on a large and small scale. Results Scientists and health-care providers may learn from one another when it comes to understanding the value of Big Data and analytics. Small data, derived by patients and consumers, also requires analytics to become actionable. Connectivism provides a framework for the use of Big Data and analytics in the areas of science and healthcare. This theory assists individuals to recognize and synthesize how human connections are driving the increase in data. Despite the volume and velocity of Big Data, it is truly about technology connecting humans and assisting them to construct knowledge in new ways. Concluding Thoughts The concept of Big Data and associated analytics are to be taken seriously when approaching the use of vast volumes of both structured and unstructured data in science and health-care. Future exploration of issues surrounding data privacy, confidentiality, and education are needed. A greater focus on data from social media, the quantified self-movement, and the application of analytics to “small data” would also be useful. PMID:25123717

  17. Big Data in Science and Healthcare: A Review of Recent Literature and Perspectives. Contribution of the IMIA Social Media Working Group.

    PubMed

    Hansen, M M; Miron-Shatz, T; Lau, A Y S; Paton, C

    2014-08-15

    As technology continues to evolve and rise in various industries, such as healthcare, science, education, and gaming, a sophisticated concept known as Big Data is surfacing. The concept of analytics aims to understand data. We set out to portray and discuss perspectives of the evolving use of Big Data in science and healthcare and, to examine some of the opportunities and challenges. A literature review was conducted to highlight the implications associated with the use of Big Data in scientific research and healthcare innovations, both on a large and small scale. Scientists and health-care providers may learn from one another when it comes to understanding the value of Big Data and analytics. Small data, derived by patients and consumers, also requires analytics to become actionable. Connectivism provides a framework for the use of Big Data and analytics in the areas of science and healthcare. This theory assists individuals to recognize and synthesize how human connections are driving the increase in data. Despite the volume and velocity of Big Data, it is truly about technology connecting humans and assisting them to construct knowledge in new ways. Concluding Thoughts: The concept of Big Data and associated analytics are to be taken seriously when approaching the use of vast volumes of both structured and unstructured data in science and health-care. Future exploration of issues surrounding data privacy, confidentiality, and education are needed. A greater focus on data from social media, the quantified self-movement, and the application of analytics to "small data" would also be useful.

  18. 40 CFR 1054.635 - What special provisions apply for small-volume engine and equipment manufacturers?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... special provisions in this part for small-volume engine and equipment manufacturers. (a) If you qualify... qualify under paragraph (1) or (2) of the definition of small-volume engine manufacturer or under...) Additional lead time and other provisions related to the transition to new emission standards. See § 1054.145...

  19. [A new method for determining the body composition with the aid of a displacement balance and low-pressure volumetric analysis (author's transl)].

    PubMed

    Schmid, P; Schlick, W; Irsigler, K

    1976-01-09

    A new method for determination of the specific weight of the gas-free human body is presented. Volume measurement is facilitated by extremely precise scales, by means of which a well-defined amount of water which was removed from a "patient container" is weighed. After the test subject has entered the container and is standing up to the neck in water, the container is closed. The combined gas volume consisting of the subject's lung volume, his intestinal gas and the air around his head is measured by lowering the pressure by an exactly-defined amount. This is done by opening a valve at the bottom of the container, which results in the outflow of a certain amount of water, the volume of which corresponds to the volume expansion inside the container. The gas volume prior to expansion can then be calculated by application of the gas laws. The advantages of this measuring device are its relatively small size, the high precision and the fact that the procedure is not unpleasant for the subject, as the head is not submerged under water.

  20. Molecular Volumes and the Stokes-Einstein Equation

    ERIC Educational Resources Information Center

    Edward, John T.

    1970-01-01

    Examines the limitations of the Stokes-Einstein equation as it applies to small solute molecules. Discusses molecular volume determinations by atomic increments, molecular models, molar volumes of solids and liquids, and molal volumes. Presents an empirical correction factor for the equation which applies to molecular radii as small as 2 angstrom…

  1. Is orbital volume associated with eyeball and visual cortex volume in humans?

    PubMed

    Pearce, Eiluned; Bridge, Holly

    2013-01-01

    In humans orbital volume increases linearly with absolute latitude. Scaling across mammals between visual system components suggests that these larger orbits should translate into larger eyes and visual cortices in high latitude humans. Larger eyes at high latitudes may be required to maintain adequate visual acuity and enhance visual sensitivity under lower light levels. To test the assumption that orbital volume can accurately index eyeball and visual cortex volumes specifically in humans. Structural Magnetic Resonance Imaging (MRI) techniques are employed to measure eye and orbit (n = 88) and brain and visual cortex (n = 99) volumes in living humans. Facial dimensions and foramen magnum area (a proxy for body mass) were also measured. A significant positive linear relationship was found between (i) orbital and eyeball volumes, (ii) eyeball and visual cortex grey matter volumes and (iii) different visual cortical areas, independently of overall brain volume. In humans the components of the visual system scale from orbit to eye to visual cortex volume independently of overall brain size. These findings indicate that orbit volume can index eye and visual cortex volume in humans, suggesting that larger high latitude orbits do translate into larger visual cortices.

  2. Is orbital volume associated with eyeball and visual cortex volume in humans?

    PubMed Central

    Pearce, Eiluned; Bridge, Holly

    2013-01-01

    Background In humans orbital volume increases linearly with absolute latitude. Scaling across mammals between visual system components suggests that these larger orbits should translate into larger eyes and visual cortices in high latitude humans. Larger eyes at high latitudes may be required to maintain adequate visual acuity and enhance visual sensitivity under lower light levels. Aim To test the assumption that orbital volume can accurately index eyeball and visual cortex volumes specifically in humans. Subjects & Methods Structural Magnetic Resonance Imaging (MRI) techniques are employed to measure eye and orbit (N=88), and brain and visual cortex (N=99) volumes in living humans. Facial dimensions and foramen magnum area (a proxy for body mass) were also measured. Results A significant positive linear relationship was found between (i) orbital and eyeball volumes, (ii) eyeball and visual cortex grey matter volumes, (iii) different visual cortical areas, independently of overall brain volume. Conclusion In humans the components of the visual system scale from orbit to eye to visual cortex volume independently of overall brain size. These findings indicate that orbit volume can index eye and visual cortex volume in humans, suggesting that larger high latitude orbits do translate into larger visual cortices. PMID:23879766

  3. Retro-Nasal Aroma Release Is Correlated with Variations in the In-Mouth Air Cavity Volume after Empty Deglutition

    PubMed Central

    Mishellany-Dutour, Anne; Woda, Alain; Labouré, Hélène; Bourdiol, Pierre; Lachaze, Pauline; Guichard, Elisabeth; Feron, Gilles

    2012-01-01

    We hypothesized that interindividual differences in motor activities during chewing and/or swallowing were determining factors for the transfer of volatile aroma from the in-mouth air cavity (IMAC) toward the olfactory mucosa. In our first experiment, we looked for changes in IMAC volume after saliva deglutition in 12 healthy subjects. The mean IMAC volume was measured after empty deglutition using an acoustic pharyngometer device. Based on the time course of the IMAC volume after swallowing, we discerned two groups of subjects. The first group displayed a small, constant IMAC volume (2.26 mL ±0.62) that corresponded to a high tongue position. The second group displayed a progressive increase in IMAC (from 6.82 mL ±2.37 to 22.82 mL ±3.04) that corresponded to a progressive lowering of the tongue to its resting position. In our second experiment, we investigated the relationship between IMAC volume changes after deglutition and the level of aroma release at the nostril. For this purpose, the release of menthone was measured at the nostril level in 25 subjects who consumed similar amounts of a mint tablet. The subjects were separated into two groups corresponding to two levels of menthone release: high (H) and low (L). The mean volume of IMAC was measured during and after empty deglutition. Group H displayed a small, constant amplitude of IMAC volume change after deglutition, while Group L displayed a progressive increase in IMAC. It is likely that Group H continuously released the aroma through the veloglossal isthmus as the mint was consumed, while Group L trapped the aroma in the oral cavity and then released it into the nasal cavity upon swallowing. These results show that the in vivo aroma release profile in humans depends closely on the different motor patterns at work during empty deglutition. PMID:22815986

  4. Full Body Loading for Small Exercise Devices Project

    NASA Technical Reports Server (NTRS)

    Downs, Meghan; Hanson, Andrea; Newby, Nathaniel

    2015-01-01

    Protecting astronauts' spine, hip, and lower body musculoskeletal strength will be critical to safely and efficiently perform physically demanding vehicle egress, exploration, and habitat building activities necessary to expand human presence in the solar system. Functionally limiting decrements in musculoskeletal health are likely during Mars proving-ground and Earth-independent missions given extended transit times and the vehicle limitations for exercise devices (low-mass, small volume). Most small exercise device concepts are designed with single-cable loading, which inhibits the ability to perform full body exercises requiring two-point loading at the shoulders. Shoulder loading is critical to protect spine, hip, and lower body musculoskeletal strength. We propose a novel low-mass, low-maintenance, and rapid deploy pulley-based system that can attach to a single-cable small exercise device to enable two-point loading at the shoulders. This attachment could protect astronauts' health and save cost, space, and energy during all phases of the Journey to Mars.

  5. Technology Overview and Assessment for Small-Scale EDL Systems

    NASA Technical Reports Server (NTRS)

    Heidrich, Casey R.; Smith, Brandon P.; Braun, Robert D.

    2016-01-01

    Motivated by missions to land large rovers and humans at Mars and other bodies, high-mass EDL technologies are a prevalent trend in the research community. In contrast, EDL systems for low-mass payloads have attracted less attention. Significant potential in science and discovery exists in small-scale EDL systems. Payloads acting secondary to a flagship mission are a currently under-utilzed resource. Before taking advantage of these opportunities, further developed of scaled EDL technologies is required. The key limitations identified in this study are compact decelerators and deformable impact systems. Current technologies may enable rough landing of small payloads, with moderate restrictions in packaging volume. Utilization of passive descent and landing stages will greatly increase the applicability of small systems, allowing for vehicles robust to entry environment uncertainties. These architectures will provide an efficient means of achieving science and support objectives while reducing cost and risk margins of a parent mission.

  6. Supraclavicular skin temperature as a measure of 18F-FDG uptake by BAT in human subjects.

    PubMed

    Boon, Mariëtte R; Bakker, Leontine E H; van der Linden, Rianne A D; Pereira Arias-Bouda, Lenka; Smit, Frits; Verberne, Hein J; van Marken Lichtenbelt, Wouter D; Jazet, Ingrid M; Rensen, Patrick C N

    2014-01-01

    Brown adipose tissue (BAT) has emerged as a novel player in energy homeostasis in humans and is considered a potential new target for combating obesity and related diseases. The current 'gold standard' for quantification of BAT volume and activity is cold-induced 18F-FDG uptake in BAT. However, use of this technique is limited by cost and radiation exposure. Given the fact that BAT is a thermogenic tissue, mainly located in the supraclavicular region, the aim of the current study was to investigate whether cold-induced supraclavicular skin temperature and core body temperature may be alternative markers of BAT activation in humans. BAT volume and activity were measured in 24 healthy lean adolescent males (mean age 24.1±0.8 years), using cold-induced 18F-FDG uptake with PET-CT. Core body temperature was measured continuously in the small intestine with use of an ingestible telemetric capsule and skin temperature was measured by eighteen wireless iButtons attached to the skin following ISO-defined locations. Proximal and distal (hand/feet) skin temperatures markedly decreased upon cold exposure, while supraclavicular skin temperature significantly increased (35.2±0.1 vs. 35.5±0.1°C, p = 0.001). Furthermore, cold-induced supraclavicular skin temperature positively correlated with both total (R2 = 0.28, P = 0.010) and clavicular BAT volume (R2 = 0.20, P = 0.030) and clavicular SUVmax (R2 = 0.27, P = 0.010), while core body temperature did not. Supraclavicular skin temperature as measured by iButtons may have predictive value for BAT detection in adult humans. This is highly desirable considering the increasing interest in pharmacological interventions to stimulate BAT in human subjects. NTR 2473.

  7. How To Set Up Your Own Small Business. Volumes I-II and Overhead Transparencies.

    ERIC Educational Resources Information Center

    Fallek, Max

    This two-volume textbook and collection of overhead transparency masters is intended for use in a course in setting up a small business. The following topics are covered in the first volume: getting off to a good start, doing market research, forecasting sales, financing a small business, understanding the different legal needs of different types…

  8. Quantifying Glacier Volume Change Using UAV-Derived Imagery and Structure from Motion Photogrammetry

    NASA Astrophysics Data System (ADS)

    Decker, C. R.; La Frenierre, J.

    2017-12-01

    Glaciers in the Tropical Andes, like those worldwide, are experiencing rapid ice volume loss due to climate change. Tropical areas are of significant interest in glacier studies because they are especially sensitive to climate change. Quantifying the rate of ice volume loss is important given their sensitivity to climate change and the importance of glacier meltwater for downstream human use. Past studies have found shrinking ice surfaces areas, but finding the actual rate of volume loss gives more information about how glaciers are reacting to climate change as well as the direct hydrological effects of ice volume loss. In this study we determined the rate of ice volume loss for a debris covered section of the Reschreiter Glacier and a portion of the clean ice tongue of the Hans Meyer Glacier on Volcán Chimborazo in Ecuador. Traditional geodetic approaches of measuring ice volume change, including the use of satellite-derived digital elevation models and airborne LIDAR, are difficult in this case due to the small size of Chimborazo's glaciers, frequently cloudy conditions, and limited local resources. Instead, we obtained imagery with an Unmanned Aerial Vehicle (UAV) and processed this imagery using Structure from Motion photogrammetry. Our results are used to evaluate the role of elevation and debris cover as Chimborazo's glaciers respond to climate change.

  9. Pulmonary tissue volume, cardiac output, and diffusing capacity in sustained microgravity

    NASA Technical Reports Server (NTRS)

    Verbanck, S.; Larsson, H.; Linnarsson, D.; Prisk, G. K.; West, J. B.; Paiva, M.

    1997-01-01

    In microgravity (microG) humans have marked changes in body fluids, with a combination of an overall fluid loss and a redistribution of fluids in the cranial direction. We investigated whether interstitial pulmonary edema develops as a result of a headward fluid shift or whether pulmonary tissue fluid volume is reduced as a result of the overall loss of body fluid. We measured pulmonary tissue volume (Vti), capillary blood flow, and diffusing capacity in four subjects before, during, and after 10 days of exposure to microG during spaceflight. Measurements were made by rebreathing a gas mixture containing small amounts of acetylene, carbon monoxide, and argon. Measurements made early in flight in two subjects showed no change in Vti despite large increases in stroke volume (40%) and diffusing capacity (13%) consistent with increased pulmonary capillary blood volume. Late in-flight measurements in four subjects showed a 25% reduction in Vti compared with preflight controls (P < 0.001). There was a concomittant reduction in stroke volume, to the extent that it was no longer significantly different from preflight control. Diffusing capacity remained elevated (11%; P < 0.05) late in flight. These findings suggest that, despite increased pulmonary perfusion and pulmonary capillary blood volume, interstitial pulmonary edema does not result from exposure to microG.

  10. Volume estimation of small phantoms and rat kidneys using three-dimensional ultrasonography and a position sensor.

    PubMed

    Strømmen, Kenneth; Stormark, Tor André; Iversen, Bjarne M; Matre, Knut

    2004-09-01

    To evaluate the accuracy of small volume estimation, both in vivo and in vitro, measurements with a three-dimensional (3D) ultrasound (US) system were carried out. A position sensor was used and the transmitting frequency was 10 MHz. Balloons with known volumes were scanned while rat kidneys were scanned in vivo and in vitro. The Archimedes' principle was used to estimate the true volume. For balloons, the 3D US system gave very good agreement with true volumes in the volume range 0.1 to 10.0 mL (r = 0.999, n = 45, mean difference +/- 2SD = 0.245 +/- 0.370 mL). For rat kidneys in vivo (volume range 0.6 to 2.7 mL) the method was less accurate (r = 0.800, n = 10, mean difference +/- 2SD = -0.288 +/- 0.676 mL). For rat kidneys in vitro (volume range 0.3 to 2.7 mL) the results showed good agreement (r = 0.981, n = 23, mean difference +/- 2SD = 0.039 +/- 0.254 mL). For balloons, kidneys in vivo and in vitro, the mean percentage error was 9.3 +/- 4.8%, -17.1 +/- 17.4%, and 4.6 +/- 11.5%, respectively. This method can estimate the volume of small phantoms and rat kidneys and opens new possibilities for volume measurements of small objects and the study of organ function in small animals. (E-mail ).

  11. Effect of small flow reversals on aerosol mixing in the alveolar region of the human lung.

    PubMed

    Darquenne, Chantal; Prisk, G Kim

    2004-12-01

    It has been suggested that irreversibility of alveolar flow combined with a stretched and folded pattern of streamlines can lead to a sudden increase in mixing in the lung. To determine whether this phenomenon is operative in the human lung in vivo, we performed a series of bolus studies with a protocol designed to induce complex folding patterns. Boli of 0.5- and 1-microm-diameter particles were inhaled at penetration volumes (V(p)) of 300 and 1,200 ml in eight subjects during short periods of microgravity aboard the National Aeronautics and Space Administration Microgravity Research Aircraft. Inspiration was from residual volume to 1 liter above 1 G functional residual capacity. This was followed by a 10-s breathhold, during which up to seven 100-ml flow reversals (FR) were imposed at V(p) = 300 ml and up to four 500-ml FR at V(p) = 1,200 ml, and by an expiration to residual volume. Bolus dispersion and deposition were calculated from aerosol concentration and flow rate continuously monitored at the mouth. There was no significant increase in dispersion and deposition with increasing FR except for dispersion between 0 and 7 FR at V(p) = 300 ml with 0.5-microm-diameter particles, and this increase was small. This suggested that either the phenomenon of stretch and fold did not occur within the number of FR we performed or that it had already occurred during the one breathing cycle included in the basic maneuver. We speculate that the phenomenon occurred during the basic maneuver, which is consistent with the high degree of dispersion and deposition observed previously in microgravity.

  12. 'Non-hypotensive' hypovolaemia reduces ascending aortic dimensions in humans

    NASA Technical Reports Server (NTRS)

    Taylor, J. A.; Halliwill, J. R.; Brown, T. E.; Hayano, J.; Eckberg, D. L.

    1995-01-01

    1. The notion that small, 'non-hypotensive' reductions of effective blood volume alter neither arterial pressure nor arterial baroreceptor activity is pervasive in the experimental literature. We tested two hypotheses: (a) that minute arterial pressure and cardiac autonomic outflow changes during hypovolaemia induced by lower body suction in humans are masked by alterations in breathing, and (b) that evidence for arterial baroreflex engagement might be obtained from measurements of thoracic aorta dimensions. 2. In two studies, responses to graded lower body suction at 0 (control), 5, 10, 15, 20 and 40 mmHg were examined in twelve and ten healthy young men, respectively. In the first, arterial pressure (photoplethysmograph), R-R interval, and respiratory sinus arrhythmia amplitude (complex demodulation) were measured during uncontrolled and controlled breathing (constant breathing frequency and tidal volume). In the second, cross-sectional areas of the ascending thoracic aorta were calculated from nuclear magnetic resonance images. 3. Lower body suction with controlled breathing resulted in an increased arterial pulse pressure at mild levels (5-20 mmHg; ANOVA, P < 0.05) and a decreased arterial pulse pressure at moderate levels (40 mmHg; ANOVA, P < 0.05). Both R-R intervals and respiratory sinus arrhythmia were negatively related to lower body suction level, whether group averages (general linear regression, r > 0.92) or individual subjects (orthogonal polynomials, 12 of 12 subjects) were assessed. 4. Aortic pulse area decreased progressively and significantly during mild lower body suction, with 47% of the total decline occurring by 5 mmHg. 5. These results suggest that small reductions of effective blood volume reduce aortic baroreceptive areas and trigger haemodynamic adjustments which are so efficient that alterations in arterial pressure escape detection by conventional means.

  13. Development of a Preclinical Orthotopic Xenograft Model of Ewing Sarcoma and Other Human Malignant Bone Disease Using Advanced In Vivo Imaging

    PubMed Central

    Batey, Michael A.; Almeida, Gilberto S.; Wilson, Ian; Dildey, Petra; Sharma, Abhishek; Blair, Helen; Hide, I. Geoff; Heidenreich, Olaf; Vormoor, Josef; Maxwell, Ross J.; Bacon, Chris M.

    2014-01-01

    Ewing sarcoma and osteosarcoma represent the two most common primary bone tumours in childhood and adolescence, with bone metastases being the most adverse prognostic factor. In prostate cancer, osseous metastasis poses a major clinical challenge. We developed a preclinical orthotopic model of Ewing sarcoma, reflecting the biology of the tumour-bone interactions in human disease and allowing in vivo monitoring of disease progression, and compared this with models of osteosarcoma and prostate carcinoma. Human tumour cell lines were transplanted into non-obese diabetic/severe combined immunodeficient (NSG) and Rag2−/−/γc−/− mice by intrafemoral injection. For Ewing sarcoma, minimal cell numbers (1000–5000) injected in small volumes were able to induce orthotopic tumour growth. Tumour progression was studied using positron emission tomography, computed tomography, magnetic resonance imaging and bioluminescent imaging. Tumours and their interactions with bones were examined by histology. Each tumour induced bone destruction and outgrowth of extramedullary tumour masses, together with characteristic changes in bone that were well visualised by computed tomography, which correlated with post-mortem histology. Ewing sarcoma and, to a lesser extent, osteosarcoma cells induced prominent reactive new bone formation. Osteosarcoma cells produced osteoid and mineralised “malignant” bone within the tumour mass itself. Injection of prostate carcinoma cells led to osteoclast-driven osteolytic lesions. Bioluminescent imaging of Ewing sarcoma xenografts allowed easy and rapid monitoring of tumour growth and detection of tumour dissemination to lungs, liver and bone. Magnetic resonance imaging proved useful for monitoring soft tissue tumour growth and volume. Positron emission tomography proved to be of limited use in this model. Overall, we have developed an orthotopic in vivo model for Ewing sarcoma and other primary and secondary human bone malignancies, which resemble the human disease. We have shown the utility of small animal bioimaging for tracking disease progression, making this model a useful assay for preclinical drug testing. PMID:24409320

  14. Small tractors for harvesting fuelwood in low-volume small-diameter hardwood stands

    Treesearch

    Neil K. Huyler; Chris B. LeDoux

    1989-01-01

    Much of the nonindustrial, private forest land in the Northeast is characterized by small diameter trees with low volume. Conventional harvesting systems used in logging these stands generally results in submarginal economic returns. Often, small-scale harvesting systems have economic advantages in these areas. Time and motion studies were conducted for several small...

  15. Human Habitation in a Lunar Electric Rover During a 14-Day Field Trial

    NASA Technical Reports Server (NTRS)

    Litaker, Harry, Jr.; Thompson, Shelby; Howard, Robert, Jr.

    2010-01-01

    Various military and commercial entities, as well as the National Aeronautics and Space Administration (NASA), have conducted space cabin confinement studies. However, after an extensive literature search, only one study was found using a simulated lunar rover (LUNEX II), under laboratory conditions, with a crew of two for an eighteen day lunar mission. Forty-three years later, NASA human factors engineers conducted a similar study using the Lunar Electric Rover (LER) in a dynamic real-world lunar simulation at the Black Point Lava Flow in Arizona. The objective of the study was to obtain human-in-the-loop performance data on the vehicle s interior volume with respect to human-system interfaces, crew accommodations, and habitation over a 14-day mission. Though part of a larger study including 212 overall operational elements, this paper will discuss only the performance of fifty different daily habitational elements within the confines of the vehicle carried out by two male subjects. Objective timing data and subjective questionnaire data were collected. Results indicate, much like the LUNEX II study, the LER field study suggest that a crew of two was able to maintain a satisfactory performance of tasks throughout the 14-day field trail within a relative small vehicle volume.

  16. Integrated Parallel Processes: The Elements of Meaning in Language. Volume IV.

    DTIC Science & Technology

    1981-11-01

    times linguistics and psychology have sought them. Religion is deeply involved, and anthropology and sociology are in important ways relevant. The...quite cir’rly. No matter what heights the human mind can at- tain, it can work only with the organs it has and the functions peculiar to them. Eyes that...is speci- fied. If a neighborhood is specified with respect to outline, colour and texture, then all objects in a sufficiently small neighborhood will

  17. Experimental prestorage filtration removes antibodies and decreases lipids in RBC supernatants mitigating TRALI in vivo

    PubMed Central

    Kelher, Marguerite R.; Khan, Samina Y.; LaSarre, Monica; West, F. Bernadette; Land, Kevin J.; Mish, Barbara; Ceriano, Linda; Sowemimo-Coker, Samuel

    2014-01-01

    Transfusion-related acute lung injury (TRALI) remains a significant cause of transfusion-related mortality with red cell transfusion. We hypothesize that prestorage filtration may reduce proinflammatory activity in the red blood cell (RBC) supernatant and prevent TRALI. Filters were manufactured for both small volumes and RBC units. Plasma containing antibodies to human lymphocyte antigen (HLA)-A2 or human neutrophil antigen (HNA)-3a was filtered, and immunoglobulins and specific HNA-3a and HLA-2a neutrophil (PMN) priming activity were measured. Antibodies to OX27 were added to plasma, and filtration was evaluated in a 2-event animal model of TRALI. RBC units from 31 donors known to have antibodies against HLA antigens and from 16 antibody-negative controls were filtered. Furthermore, 4 RBC units were drawn and underwent standard leukoreduction. Immunoglobulins, HLA antibodies, PMN priming activity, and the ability to induce TRALI in an animal model were measured. Small-volume filtration of plasma removed >96% of IgG, antibodies to HLA-A2 and HNA-3a, and their respective priming activity, as well as mitigating antibody-mediated in vivo TRALI. In RBC units, experimental filtration removed antibodies to HLA antigens and inhibited the accumulation of lipid priming activity and lipid-mediated TRALI. We conclude that filtration removes proinflammatory activity and the ability to induce TRALI from RBCs and may represent a TRALI mitigation step. PMID:24747436

  18. Method for preparing small volume reaction containers

    DOEpatents

    Retterer, Scott T.; Doktycz, Mitchel J.

    2017-04-25

    Engineered reaction containers that can be physically and chemically defined to control the flux of molecules of different sizes and charge are disclosed. Methods for constructing small volume reaction containers through a combination of etching and deposition are also disclosed. The methods allow for the fabrication of multiple devices that possess features on multiple length scales, specifically small volume containers with controlled porosity on the nanoscale.

  19. Small Business Management and Ownership. Volume Four. Mini-Problems in Entrepreneurship.

    ERIC Educational Resources Information Center

    Shuchat, Jo

    The mini-problems presented in this volume are provided to augment the introductory course, "Minding Your Own Small Business," and the advanced course, "Something Ventured, Something Gained," in small business ownership and management. They can also be used in conjunction with other instructional materials in small business…

  20. Tumor Volume Estimation and Quasi-Continuous Administration for Most Effective Bevacizumab Therapy

    PubMed Central

    Sápi, Johanna; Kovács, Levente; Drexler, Dániel András; Kocsis, Pál; Gajári, Dávid; Sápi, Zoltán

    2015-01-01

    Background Bevacizumab is an exogenous inhibitor which inhibits the biological activity of human VEGF. Several studies have investigated the effectiveness of bevacizumab therapy according to different cancer types but these days there is an intense debate on its utility. We have investigated different methods to find the best tumor volume estimation since it creates the possibility for precise and effective drug administration with a much lower dose than in the protocol. Materials and Methods We have examined C38 mouse colon adenocarcinoma and HT-29 human colorectal adenocarcinoma. In both cases, three groups were compared in the experiments. The first group did not receive therapy, the second group received one 200 μg bevacizumab dose for a treatment period (protocol-based therapy), and the third group received 1.1 μg bevacizumab every day (quasi-continuous therapy). Tumor volume measurement was performed by digital caliper and small animal MRI. The mathematical relationship between MRI-measured tumor volume and mass was investigated to estimate accurate tumor volume using caliper-measured data. A two-dimensional mathematical model was applied for tumor volume evaluation, and tumor- and therapy-specific constants were calculated for the three different groups. The effectiveness of bevacizumab administration was examined by statistical analysis. Results In the case of C38 adenocarcinoma, protocol-based treatment did not result in significantly smaller tumor volume compared to the no treatment group; however, there was a significant difference between untreated mice and mice who received quasi-continuous therapy (p = 0.002). In the case of HT-29 adenocarcinoma, the daily treatment with one-twelfth total dose resulted in significantly smaller tumors than the protocol-based treatment (p = 0.038). When the tumor has a symmetrical, solid closed shape (typically without treatment), volume can be evaluated accurately from caliper-measured data with the applied two-dimensional mathematical model. Conclusion Our results provide a theoretical background for a much more effective bevacizumab treatment using optimized administration. PMID:26540189

  1. Tumor Volume Estimation and Quasi-Continuous Administration for Most Effective Bevacizumab Therapy.

    PubMed

    Sápi, Johanna; Kovács, Levente; Drexler, Dániel András; Kocsis, Pál; Gajári, Dávid; Sápi, Zoltán

    2015-01-01

    Bevacizumab is an exogenous inhibitor which inhibits the biological activity of human VEGF. Several studies have investigated the effectiveness of bevacizumab therapy according to different cancer types but these days there is an intense debate on its utility. We have investigated different methods to find the best tumor volume estimation since it creates the possibility for precise and effective drug administration with a much lower dose than in the protocol. We have examined C38 mouse colon adenocarcinoma and HT-29 human colorectal adenocarcinoma. In both cases, three groups were compared in the experiments. The first group did not receive therapy, the second group received one 200 μg bevacizumab dose for a treatment period (protocol-based therapy), and the third group received 1.1 μg bevacizumab every day (quasi-continuous therapy). Tumor volume measurement was performed by digital caliper and small animal MRI. The mathematical relationship between MRI-measured tumor volume and mass was investigated to estimate accurate tumor volume using caliper-measured data. A two-dimensional mathematical model was applied for tumor volume evaluation, and tumor- and therapy-specific constants were calculated for the three different groups. The effectiveness of bevacizumab administration was examined by statistical analysis. In the case of C38 adenocarcinoma, protocol-based treatment did not result in significantly smaller tumor volume compared to the no treatment group; however, there was a significant difference between untreated mice and mice who received quasi-continuous therapy (p = 0.002). In the case of HT-29 adenocarcinoma, the daily treatment with one-twelfth total dose resulted in significantly smaller tumors than the protocol-based treatment (p = 0.038). When the tumor has a symmetrical, solid closed shape (typically without treatment), volume can be evaluated accurately from caliper-measured data with the applied two-dimensional mathematical model. Our results provide a theoretical background for a much more effective bevacizumab treatment using optimized administration.

  2. QuEST for malware type-classification

    NASA Astrophysics Data System (ADS)

    Vaughan, Sandra L.; Mills, Robert F.; Grimaila, Michael R.; Peterson, Gilbert L.; Oxley, Mark E.; Dube, Thomas E.; Rogers, Steven K.

    2015-05-01

    Current cyber-related security and safety risks are unprecedented, due in no small part to information overload and skilled cyber-analyst shortages. Advances in decision support and Situation Awareness (SA) tools are required to support analysts in risk mitigation. Inspired by human intelligence, research in Artificial Intelligence (AI) and Computational Intelligence (CI) have provided successful engineering solutions in complex domains including cyber. Current AI approaches aggregate large volumes of data to infer the general from the particular, i.e. inductive reasoning (pattern-matching) and generally cannot infer answers not previously programmed. Whereas humans, rarely able to reason over large volumes of data, have successfully reached the top of the food chain by inferring situations from partial or even partially incorrect information, i.e. abductive reasoning (pattern-completion); generating a hypothetical explanation of observations. In order to achieve an engineering advantage in computational decision support and SA we leverage recent research in human consciousness, the role consciousness plays in decision making, modeling the units of subjective experience which generate consciousness, qualia. This paper introduces a novel computational implementation of a Cognitive Modeling Architecture (CMA) which incorporates concepts of consciousness. We apply our model to the malware type-classification task. The underlying methodology and theories are generalizable to many domains.

  3. Human sinus arrhythmia as an index of vagal cardiac outflow

    NASA Technical Reports Server (NTRS)

    Eckberg, D. L.

    1983-01-01

    The human central vagal mechanisms were investigated by measuring the intervals between heartbeats during controlled breathing (at breathing intervals of 2.5-10 s and nominal tidal volumes of 1000 and 1500 ml) in six young men and women. It was found that as the breathing interval increased, the longest heart periods became longer, the shortest heart periods became shorter, and the peak-valley P-P intervals increased asymptotically. Peak-valley intervals also increased in proportion to tidal volume, although this influence was small. The phase angles between heart period changes and respiration were found to vary as linear functions of breathing interval. Heart period shortening began in inspiration at short breathing intervals and in expiration at long breathing intervals, while heart period lengthening began in early expiration at all breathing intervals studied. It is concluded that a close relationship exists between variations of respiratory depth and interval and the quantity, periodicity, and timing of vagal cardiac outflow in conscious humans. The results indicate that at usual breathing rates, phasic respiration-related changes of vagal motoneuron activity begin in expiration, progress slowly, and are incompletely expressed at fast breathing ratges.

  4. Satellite Observations of Antarctic Sea Ice Thickness and Volume

    NASA Technical Reports Server (NTRS)

    Kurtz, Nathan; Markus, Thorsten

    2012-01-01

    We utilize satellite laser altimetry data from ICESat combined with passive microwave measurements to analyze basin-wide changes in Antarctic sea ice thickness and volume over a 5 year period from 2003-2008. Sea ice thickness exhibits a small negative trend while area increases in the summer and fall balanced losses in thickness leading to small overall volume changes. Using a five year time-series, we show that only small ice thickness changes of less than -0.03 m/yr and volume changes of -266 cu km/yr and 160 cu km/yr occurred for the spring and summer periods, respectively. The calculated thickness and volume trends are small compared to the observational time period and interannual variability which masks the determination of long-term trend or cyclical variability in the sea ice cover. These results are in stark contrast to the much greater observed losses in Arctic sea ice volume and illustrate the different hemispheric changes of the polar sea ice covers in recent years.

  5. Apparatus and method for collection and concentration of respirable particles into a small fluid volume

    DOEpatents

    Simon, Jonathan N.; Brown, Steve B.

    2002-01-01

    An apparatus and method for the collection of respirable particles and concentration of such particles into a small fluid volume. The apparatus captures and concentrates small (1-10 .mu.m) respirable particles into a sub-millileter volume of fluid. The method involves a two step operation, collection and concentration: wherein collection of particles is by a wetted surface having small vertical slits that act as capillary channels; and concentration is carried out by transfer of the collected particles to a small volume (sub-milliliter) container by centrifugal force whereby the particles are forced through the vertical slits and contact a non-wetted wall surface, and are deflected to the bottom where they are contained for analysis, such as a portable flow cytometer or a portable PCR DNA analysis system.

  6. Smart fast blood counting of trace volumes of body fluids from various mammalian species using a compact custom-built microscope cytometer (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Smith, Zachary J.; Gao, Tingjuan; Lin, Tzu-Yin; Carrade-Holt, Danielle; Lane, Stephen M.; Matthews, Dennis L.; Dwyre, Denis M.; Wachsmann-Hogiu, Sebastian

    2016-03-01

    Cell counting in human body fluids such as blood, urine, and CSF is a critical step in the diagnostic process for many diseases. Current automated methods for cell counting are based on flow cytometry systems. However, these automated methods are bulky, costly, require significant user expertise, and are not well suited to counting cells in fluids other than blood. Therefore, their use is limited to large central laboratories that process enough volume of blood to recoup the significant capital investment these instruments require. We present in this talk a combination of a (1) low-cost microscope system, (2) simple sample preparation method, and (3) fully automated analysis designed for providing cell counts in blood and body fluids. We show results on both humans and companion and farm animals, showing that accurate red cell, white cell, and platelet counts, as well as hemoglobin concentration, can be accurately obtained in blood, as well as a 3-part white cell differential in human samples. We can also accurately count red and white cells in body fluids with a limit of detection ~3 orders of magnitude smaller than current automated instruments. This method uses less than 1 microliter of blood, and less than 5 microliters of body fluids to make its measurements, making it highly compatible with finger-stick style collections, as well as appropriate for small animals such as laboratory mice where larger volume blood collections are dangerous to the animal's health.

  7. Comparison of a Point-of-Care Glucometer and a Laboratory Autoanalyzer for Measurement of Blood Glucose Concentrations in Domestic Pigeons ( Columba livia domestica).

    PubMed

    Mohsenzadeh, Mahdieh Sadat; Zaeemi, Mahdieh; Razmyar, Jamshid; Azizzadeh, Mohammad

    2015-09-01

    Biochemical analysis is necessary for diagnosis and monitoring of diseases in birds; however, the small volume of blood that can be safely obtained from small avian species often limits laboratory diagnostic testing. Consequently, a suitable methodology requiring only a small volume of blood must be used. This study was designed to compare blood glucose concentrations in domestic pigeons ( Columba livia domestica) as measured by a commercial, handheld, human glucometer and a standard autoanalyzer. During the first phase of the study, whole blood samples obtained from 30 domestic pigeons were used to measure the blood glucose concentration with a glucometer, the packed cell volume (PCV), and the total erythrocyte count (nRBC). Plasma separated from the each sample was then used to obtain the plasma glucose concentration with the autoanalyzer. During the second phase of the study, 30 pigeons were assigned to 2 equal groups (n = 15). Hypoglycemia or hyperglycemia was induced in each group by intravenous injection of insulin or glucose, respectively. Blood was collected and processed, and glucose concentrations, PCV, and nRBC were measured as previously described. Linear-regression models demonstrated a significant relationship between results measured by the glucometer and autoanalyzer results from normoglycemic (correlation coefficient [R] = 0.43, P = .02), hypoglycemic (R = 0.95; P < .001), and hyperglycemic (R = 0.81; P < .001) birds. The results of this study suggest that we can predict the real blood-glucose concentration of pigeons by using results obtained by a glucometer.

  8. Gamma Knife irradiation method based on dosimetric controls to target small areas in rat brains

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Constanzo, Julie; Paquette, Benoit; Charest, Gabriel

    2015-05-15

    Purpose: Targeted and whole-brain irradiation in humans can result in significant side effects causing decreased patient quality of life. To adequately investigate structural and functional alterations after stereotactic radiosurgery, preclinical studies are needed. The purpose of this work is to establish a robust standardized method of targeted irradiation on small regions of the rat brain. Methods: Euthanized male Fischer rats were imaged in a stereotactic bed, by computed tomography (CT), to estimate positioning variations relative to the bregma skull reference point. Using a rat brain atlas and the stereotactic bregma coordinates obtained from CT images, different regions of the brainmore » were delimited and a treatment plan was generated. A single isocenter treatment plan delivering ≥100 Gy in 100% of the target volume was produced by Leksell GammaPlan using the 4 mm diameter collimator of sectors 4, 5, 7, and 8 of the Gamma Knife unit. Impact of positioning deviations of the rat brain on dose deposition was simulated by GammaPlan and validated with dosimetric measurements. Results: The authors’ results showed that 90% of the target volume received 100 ± 8 Gy and the maximum of deposited dose was 125 ± 0.7 Gy, which corresponds to an excellent relative standard deviation of 0.6%. This dose deposition calculated with GammaPlan was validated with dosimetric films resulting in a dose-profile agreement within 5%, both in X- and Z-axes. Conclusions: The authors’ results demonstrate the feasibility of standardizing the irradiation procedure of a small volume in the rat brain using a Gamma Knife.« less

  9. Coagulation measurement from whole blood using vibrating optical fiber in a disposable cartridge

    NASA Astrophysics Data System (ADS)

    Yaraş, Yusuf Samet; Gündüz, Ali Bars; Saǧlam, Gökhan; Ölçer, Selim; Civitçi, Fehmi; Baris, İbrahim; Yaralioǧlu, Göksenin; Urey, Hakan

    2017-11-01

    In clinics, blood coagulation time measurements are performed using mechanical measurements with blood plasma. Such measurements are challenging to do in a lab-on-a-chip (LoC) system using a small volume of whole blood. Existing LoC systems use indirect measurement principles employing optical or electrochemical methods. We developed an LoC system using mechanical measurements with a small volume of whole blood without requiring sample preparation. The measurement is performed in a microfluidic channel where two fibers are placed inline with a small gap in between. The first fiber operates near its mechanical resonance using remote magnetic actuation and immersed in the sample. The second fiber is a pick-up fiber acting as an optical sensor. The microfluidic channel is engineered innovatively such that the blood does not block the gap between the vibrating fiber and the pick-up fiber, resulting in high signal-to-noise ratio optical output. The control plasma test results matched well with the plasma manufacturer's datasheet. Activated-partial-thromboplastin-time tests were successfully performed also with human whole blood samples, and the method is proven to be effective. Simplicity of the cartridge design and cost of readily available materials enable a low-cost point-of-care device for blood coagulation measurements.

  10. Femtomole-Scale High-Throughput Screening of Protein Ligands with Droplet-Based Thermal Shift Assay.

    PubMed

    Liu, Wen-Wen; Zhu, Ying; Fang, Qun

    2017-06-20

    There is a great demand to measure protein-ligand interactions in rapid and low cost way. Here, we developed a microfluidic droplet-based thermal shift assay (dTSA) system for high-throughput screening of small-molecule protein ligands. The system is composed of a nanoliter droplet array chip, a microfluidic droplet robot, and a real-time fluorescence detection system. Total 324 assays could be performed in parallel in a single chip with an 18 × 18 droplet array. The consumption of dTSA for each protein or ligand sample was only 5 nL (femtomole scale), which is significantly reduced by over 3 orders of magnitude compared with those in 96- or 384-well plate-based systems. We also observed the implementation of TSA in nanoliter droplet format could substantially improve assay precision with relative standard deviation (RSD) of 0.2% (n = 50), which can be ascribed to the enhanced thermal conduction in small volume reactors. The dTSA system was optimized by studying the effect of droplet volumes, as well as protein and fluorescent dye (SYPRO Orange) concentrations. To demonstrate its potential in drug discovery, we applied the dTSA system in screening inhibitors of human thrombin with a commercial library containing 100 different small molecule compounds, and two inhibitors were successfully identified and confirmed.

  11. Adsorption of triazine herbicides from aqueous solution by functionalized multiwall carbon nanotubes grown on silicon substrate

    NASA Astrophysics Data System (ADS)

    D'Archivio, Angelo Antonio; Maggi, Maria Anna; Odoardi, Antonella; Santucci, Sandro; Passacantando, Maurizio

    2018-02-01

    Multi-walled carbon nanotubes (MWCNTs), because of their small size and large available surface area, are potentially efficient sorbents for the extraction of water solutes. Dispersion of MWCNTs in aqueous medium is suitable to adsorb organic contaminants from small sample volumes, but, the recovery of the suspended sorbent for successive re-use represents a critical step, which makes this method inapplicable in large-scale water-treatment technologies. To overcome this problem, we proposed here MWCNTs grown on silicon supports and investigated on a small-volume scale their adsorption properties towards triazine herbicides dissolved in water. The adsorption efficiency of the supported MWCNTs has been tested on seven triazine herbicides, which are emerging water contaminants in Europe and USA, because of their massive use, persistence in soils and potential risks for the aquatic organisms and human health. The investigated compounds, in spite of their common molecular skeleton, cover a relatively large property range in terms of both solubility in water and hydrophilicity/hydrophobicity. The functionalisation of MWCNTs carried out by acidic oxidation, apart from increasing wettability of the material, results in a better adsorption performance. Increasing of functionalisation time between 17 and 60 h progressively increases the extraction of all seven pesticides and produces a moderate increment of selectivity.

  12. Coagulation measurement from whole blood using vibrating optical fiber in a disposable cartridge.

    PubMed

    Yaraş, Yusuf Samet; Gündüz, Ali Bars; Sağlam, Gökhan; Ölçer, Selim; Civitçi, Fehmi; Baris, İbrahim; Yaralioğlu, Göksenin; Urey, Hakan

    2017-11-01

    In clinics, blood coagulation time measurements are performed using mechanical measurements with blood plasma. Such measurements are challenging to do in a lab-on-a-chip (LoC) system using a small volume of whole blood. Existing LoC systems use indirect measurement principles employing optical or electrochemical methods. We developed an LoC system using mechanical measurements with a small volume of whole blood without requiring sample preparation. The measurement is performed in a microfluidic channel where two fibers are placed inline with a small gap in between. The first fiber operates near its mechanical resonance using remote magnetic actuation and immersed in the sample. The second fiber is a pick-up fiber acting as an optical sensor. The microfluidic channel is engineered innovatively such that the blood does not block the gap between the vibrating fiber and the pick-up fiber, resulting in high signal-to-noise ratio optical output. The control plasma test results matched well with the plasma manufacturer's datasheet. Activated-partial-thromboplastin-time tests were successfully performed also with human whole blood samples, and the method is proven to be effective. Simplicity of the cartridge design and cost of readily available materials enable a low-cost point-of-care device for blood coagulation measurements. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  13. The impact of a forced reduction in traffic volumes on urban air pollution

    NASA Astrophysics Data System (ADS)

    Yuval; Flicstein, Bernanda; Broday, David M.

    The Middle East military conflict of summer 2006 resulted in a few weeks in which the city of Haifa, Israel, and its environs experienced very profound variations in the commercial and personal activities. Large industrial plants continued almost normal operations but activities of small scale industry, shopping, and personal commuting were drastically reduced, leading to a dramatic decrease in the commercial and personal traffic volumes. This period of reduced activity serves as a real life experiment for assessment and demonstration of the impact that human activity, and mainly road traffic, may have on the air pollution levels in a bustling middle-sized city. The analysis is made especially sharp and reliable due to the abruptness of the beginning and the end of the reduced activity period, its length, and the stable summer meteorological conditions in the eastern Mediterranean region. The reduced traffic volumes resulted in lowered levels of NO 2, hydrocarbons and particulate matter. The decrease in these pollutants' mean concentration was significantly larger than the reduction in the mean traffic volume. Slightly higher mean O 3 concentrations were observed during the reduced traffic period.

  14. Parsing partial molar volumes of small molecules: a molecular dynamics study.

    PubMed

    Patel, Nisha; Dubins, David N; Pomès, Régis; Chalikian, Tigran V

    2011-04-28

    We used molecular dynamics (MD) simulations in conjunction with the Kirkwood-Buff theory to compute the partial molar volumes for a number of small solutes of various chemical natures. We repeated our computations using modified pair potentials, first, in the absence of the Coulombic term and, second, in the absence of the Coulombic and the attractive Lennard-Jones terms. Comparison of our results with experimental data and the volumetric results of Monte Carlo simulation with hard sphere potentials and scaled particle theory-based computations led us to conclude that, for small solutes, the partial molar volume computed with the Lennard-Jones potential in the absence of the Coulombic term nearly coincides with the cavity volume. On the other hand, MD simulations carried out with the pair interaction potentials containing only the repulsive Lennard-Jones term produce unrealistically large partial molar volumes of solutes that are close to their excluded volumes. Our simulation results are in good agreement with the reported schemes for parsing partial molar volume data on small solutes. In particular, our determined interaction volumes() and the thickness of the thermal volume for individual compounds are in good agreement with empirical estimates. This work is the first computational study that supports and lends credence to the practical algorithms of parsing partial molar volume data that are currently in use for molecular interpretations of volumetric data.

  15. Comparison between Hydrogen, Methane and Ethylene Fuels in a 3-D Scramjet at Mach 8

    DTIC Science & Technology

    2016-06-24

    characteristics in air. The disadvantage of hydrogen is its low density, which is a particular problem for small vehicles with significant internal...characteristics in air. The disadvantage of hydrogen is its low density, which is a particular problem for small vehicles with significant internal volume...The low energy per unit volume of gaseous hydrogen, however, is a significant problem for small vehicles with internal volume constraints, in addition

  16. Brain tissue volumes in the general elderly population. The Rotterdam Scan Study.

    PubMed

    Ikram, M Arfan; Vrooman, Henri A; Vernooij, Meike W; van der Lijn, Fedde; Hofman, Albert; van der Lugt, Aad; Niessen, Wiro J; Breteler, Monique M B

    2008-06-01

    We investigated how volumes of cerebrospinal fluid (CSF), grey matter (GM) and white matter (WM) varied with age, sex, small vessel disease and cardiovascular risk factors in the Rotterdam Scan Study. Participants (n=490; 60-90 years) were non-demented and 51.0% had hypertension, 4.9% had diabetes mellitus, 17.8% were current smoker and 54.0% were former smoker. We segmented brain MR-images into GM, normal WM, white matter lesion (WML) and CSF. Brain infarcts were rated visually. Volumes were expressed as percentage of intra-cranial volume. With increasing age, volumes of total brain, normal WM and total WM decreased; that of GM remained unchanged; and that of WML increased, in both men and women. Excluding persons with infarcts did not alter these results. Persons with larger load of small vessel disease had smaller brain volume, especially normal WM volume. Diastolic blood pressure, diabetes mellitus and current smoking were also related to smaller brain volume. In the elderly, higher age, small vessel disease and cardiovascular risk factors are associated with smaller brain volume, especially WM volume.

  17. Mount Baker lahars and debris flows, ancient, modern, and future

    USGS Publications Warehouse

    Tucker, David S; Scott, Kevin M.; Grossman, Eric E.; Linneman, Scott

    2014-01-01

    Holocene lahars and large debris flows (>106 m3) have left recognizable deposits in the Middle Fork Nooksack valley. A debris flow in 2013 resulting from a landslide in a Little Ice Age moraine had an estimated volume of 100,000 m3, yet affected turbidity for the entire length of the river, and produced a slug of sediment that is currently being reworked and remobilized in the river system. Deposits of smaller-volume debris flows, deposited as terraces in the upper valley, may be entirely eroded within a few years. Consequently, the geologic record of small debris flows such as those that occurred in 2013 is probably very fragmentary. Small debris flows may still have significant impacts on hydrology, biology, and human uses of rivers downstream. Impacts include the addition of waves of fine sediment to stream loads, scouring or burying salmon-spawning gravels, forcing unplanned and sudden closure of municipal water intakes, damaging or destroying trail crossings, extending river deltas into estuaries, and adding to silting of harbors near river mouths.

  18. An improved analytical strategy combining microextraction by packed sorbent combined with ultra high pressure liquid chromatography for the determination of fluoxetine, clomipramine and their active metabolites in human urine.

    PubMed

    Alves, Vera; Gonçalves, João; Conceição, Carlota; Teixeira, Helena M; Câmara, José S

    2015-08-21

    A powerful and sensitive method, by microextraction packed sorbent (MEPS), and ultra-high performance liquid chromatography (UHPLC) with a photodiode array (PDA) detection, is described for the determination of fluoxetine, clomipramine and their active metabolites in human urine samples. The MEPS variables, such as sample volume, pH, number of extraction cycles (draw-eject), and desorption conditions (solvent and solvent volume of elution) were optimized. The analysis were carried out using small sample volumes (500μL) and in a short time period (5min for the entire sample preparation step). Good linearity was obtained for all antidepressants with the correlation coefficients (R(2)) above 0.9965. The limits of detection (LOD) ranged from 0.068 to 0.087μgmL(-1). The recoveries were from 93% to 98%, with relative standard deviations less than 6%. The inter-day precision, expressed as the relative standard deviation, varied between 3.8% and 8.5% while the intra-day precision between 3.0% and 7.1%. In order to evaluate the proposed method for clinical use, the MEPS/UHPLC-PDA method was applied to analysis of urine samples from depressed patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Color structured light system of chest wall motion measurement for respiratory volume evaluation

    NASA Astrophysics Data System (ADS)

    Chen, Huijun; Cheng, Yuan; Liu, Dongdong; Zhang, Xiaodong; Zhang, Jue; Que, Chengli; Wang, Guangfa; Fang, Jing

    2010-03-01

    We present a structured light system to dynamically measure human chest wall motion for respiratory volume estimation. Based on a projection of an encoded color pattern and a few active markers attached to the trunk, respiratory volumes are obtained by evaluating the 3-D topographic changes of the chest wall in an anatomically consistent measuring region during respiration. Three measuring setups are established: a single-sided illuminating-recording setup for standing posture, an inclined single-sided setup for supine posture, and a double-sided setup for standing posture. Results are compared with the pneumotachography and show good agreement in volume estimations [correlation coefficient: R>0.99 (P<0.001) for all setups]. The isovolume tests present small variations of the obtained volume during the isovolume maneuver (standard deviation<0.085 L for all setups). After validation by the isovolume test, an investigation of a patient with pleural effusion using the proposed method shows pulmonary functional differences between the diseased and the contralateral sides of the thorax, and subsequent improvement of this imbalance after drainage. These results demonstrate the proposed optical method is capable of not only whole respiratory volume evaluation with high accuracy, but also regional pulmonary function assessment in different chest wall behaviors, with the advantage of whole-field measurement.

  20. The human physiological impact of global deoxygenation.

    PubMed

    Martin, Daniel; McKenna, Helen; Livina, Valerie

    2017-01-01

    There has been a clear decline in the volume of oxygen in Earth's atmosphere over the past 20 years. Although the magnitude of this decrease appears small compared to the amount of oxygen in the atmosphere, it is difficult to predict how this process may evolve, due to the brevity of the collected records. A recently proposed model predicts a non-linear decay, which would result in an increasingly rapid fall-off in atmospheric oxygen concentration, with potentially devastating consequences for human health. We discuss the impact that global deoxygenation, over hundreds of generations, might have on human physiology. Exploring the changes between different native high-altitude populations provides a paradigm of how humans might tolerate worsening hypoxia over time. Using this model of atmospheric change, we predict that humans may continue to survive in an unprotected atmosphere for ~3600 years. Accordingly, without dramatic changes to the way in which we interact with our planet, humans may lose their dominance on Earth during the next few millennia.

  1. Small Power Systems Solar Electric Workshop Proceedings. Volume 1: Executive report. Volume 2: Invited papers

    NASA Technical Reports Server (NTRS)

    Ferber, R. (Editor); Evans, D. (Editor)

    1978-01-01

    The background, objectives and methodology used for the Small Power Systems Solar Electric Workshop are described, and a summary of the results and conclusions developed at the workshop regarding small solar thermal electric power systems is presented.

  2. Application of ultradisperse magnetic adsorbents for removal of small concentrations of pollutants from large volumes of water

    NASA Astrophysics Data System (ADS)

    Nechitailo, Galina S.; Kuznetsov, Anatoli; Kuznetsov, Oleg

    2016-07-01

    Pollution of natural bodies of water (rivers, lakes, ground water, etc) is unfortunately very common, both from natural sources like volcanic activity; and, even more importantly, from human activity, including disposal of industrial and municipal waste, mining, etc. Many toxic substances are harmful for humans and other organisms even in very low concentrations (e.g., less than 1 µg/L of cadmium is harmful, for Hg it is 0.5 µg/L, for phenol - 1 µg/L), and can remain in water for decades or longer. Cleaning large volumes of water even from low concentrations of pollutants is a challenging technological task and is very expensive. We propose to use suspension of ultradisperse magnetic adsorbents, for example, nanostructured ferro-carbon particles, produced by plasmachemical technique, for removing small concentrations of pollutants from large volumes of water. The suspension is introduced into the water. Due to their small sizes and densities similar to water (we measured the density of FC-4 ferro-carbon to be about 1 g/cm3; presumably due to porosity) the particles do not sediment for a long time (hours, days or longer), move due to Brownian motion and adsorb a variety of substances from the water. The particle surface can be modified to provide selectivity of the adsorption. Sorption capacities of ferro-carbon adsorbents is in dozens of percent. Therefore, to collect 1 kg of a pollutant, 2 to 20 kg of the adsorbents is required. Then the particles with the adsorbed contaminant can be collected (e.g., downstream of the river) using a variety of magnetic traps. The traps can consist of ferromagnetic wires and permanent magnets, a variety of simple and inexpensive designs are available. As a model system, the kinetics of adsorption of a highly diluted (0.002 mg/ml) aqueous solution of a low molecular weight compound (toluidine blue) by a small concentration of a ferro-carbon powder (FC-4) was studied by spectrophotometry. Before each measurement, the particles with the adsorbed toluidine blue were removed from the solution by magnetic separation. The sorbent was proven to have high sorption capacity and rapid adsorption kinetics for toluidine blue. These experiments demonstrated the validity of the method, where a small concentration of a pollutant was successfully collected from a large volume of water. By varying the ratio of the sorbent/pollutant, it is possible to optimize the sorbent use and the time required to adsorb all pollutant present in the treated water. A variety of magnetically controlled sorbents can be designed and used in this method, from broad-spectrum adsorbing sorbents to sorbents specifically targeting a particular pollutant. These sorbents can be used either individually or as mixtures of sorbents with different properties, depending on the desired purification goals. Simplicity and scalability of this method allow a variety of ecological applications, as well as industrial ones, from process water purification to wastewater treatment.

  3. Deviation from Power Law Behavior in Landslide Phenomenon

    NASA Astrophysics Data System (ADS)

    Li, L.; Lan, H.; Wu, Y.

    2013-12-01

    Power law distribution of magnitude is widely observed in many natural hazards (e.g., earthquake, floods, tornadoes, and forest fires). Landslide is unique as the size distribution of landslide is characterized by a power law decrease with a rollover in the small size end. Yet, the emergence of the rollover, i.e., the deviation from power law behavior for small size landslides, remains a mystery. In this contribution, we grouped the forces applied on landslide bodies into two categories: 1) the forces proportional to the volume of failure mass (gravity and friction), and 2) the forces proportional to the area of failure surface (cohesion). Failure occurs when the forces proportional to volume exceed the forces proportional to surface area. As such, given a certain mechanical configuration, the failure volume to failure surface area ratio must exceed a corresponding threshold to guarantee a failure. Assuming all landslides share a uniform shape, which means the volume to surface area ratio of landslide regularly increase with the landslide volume, a cutoff of landslide volume distribution in the small size end can be defined. However, in realistic landslide phenomena, where heterogeneities of landslide shape and mechanical configuration are existent, a simple cutoff of landslide volume distribution does not exist. The stochasticity of landslide shape introduce a probability distribution of the volume to surface area ratio with regard to landslide volume, with which the probability that the volume to surface ratio exceed the threshold can be estimated regarding values of landslide volume. An experiment based on empirical data showed that this probability can induce the power law distribution of landslide volume roll down in the small size end. We therefore proposed that the constraints on the failure volume to failure surface area ratio together with the heterogeneity of landslide geometry and mechanical configuration attribute for the deviation from power law behavior in landslide phenomenon. Figure shows that a rollover of landslide size distribution in the small size end is produced as the probability for V/S (the failure volume to failure surface ratio of landslide) exceeding the mechanical threshold applied to the power law distribution of landslide volume.

  4. Air and Water Processes Do Not Produce the Same High-Quality Pasteurization of Donor Human Milk.

    PubMed

    Buffin, Rachel; Pradat, Pierre; Trompette, Jocelyne; Ndiaye, Isabelle; Basson, Eliane; Jordan, Isabelle; Picaud, Jean-Charles

    2017-11-01

    Holder pasteurization is the most commonly used technique in milk banks worldwide, but higher temperatures and longer pasteurization time have been associated with damage to the immune components of human milk. Research aim: This study aimed to assess the detailed pattern of pasteurization temperature using two water pasteurizers (WP1 and WP2) and one air pasteurizer (AP). The milk temperature during each phase of the pasteurization cycle was recorded using 6 to 9 probes, depending on the number of bottles, in the pasteurizers. We used 90 to 200 ml bottles to assess the effect of volume on milk temperature. The time to heat the milk from room temperature to 58°C was 12.4, 12.9, and 64.5 min, respectively, for WP1, WP2, and the AP ( p < .0001). The duration of the plateau was 35.5, 35.2, and 45.8 min ( p < .0001). The duration of exposure to a temperature above 58°C was 49.6, 40.7, and 76.2 min ( p < .0001). The total duration of a full cycle was 79, 66, and 182 min ( p < .0001). The duration of exposure above 58°C for the different volumes of milk treated showed no difference when using WP1 but was significantly longer in small volumes when using WP2. Human milk treated using the air pasteurizer in our study was exposed to higher temperatures and for longer periods of time than the water pasteurizers we employed. Regular qualification of pasteurizers is requested when evaluating the effect of pasteurization on milk components and for routine treatment of human milk in milk banks.

  5. 40 CFR 80.595 - How does a small or GPA refiner apply for a motor vehicle diesel fuel volume baseline for the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... for a motor vehicle diesel fuel volume baseline for the purpose of extending their gasoline sulfur... a small or GPA refiner apply for a motor vehicle diesel fuel volume baseline for the purpose of... duration of the GPA standards under § 80.540 must apply for a motor vehicle diesel fuel volume baseline by...

  6. Neuronal factors determining high intelligence.

    PubMed

    Dicke, Ursula; Roth, Gerhard

    2016-01-05

    Many attempts have been made to correlate degrees of both animal and human intelligence with brain properties. With respect to mammals, a much-discussed trait concerns absolute and relative brain size, either uncorrected or corrected for body size. However, the correlation of both with degrees of intelligence yields large inconsistencies, because although they are regarded as the most intelligent mammals, monkeys and apes, including humans, have neither the absolutely nor the relatively largest brains. The best fit between brain traits and degrees of intelligence among mammals is reached by a combination of the number of cortical neurons, neuron packing density, interneuronal distance and axonal conduction velocity--factors that determine general information processing capacity (IPC), as reflected by general intelligence. The highest IPC is found in humans, followed by the great apes, Old World and New World monkeys. The IPC of cetaceans and elephants is much lower because of a thin cortex, low neuron packing density and low axonal conduction velocity. By contrast, corvid and psittacid birds have very small and densely packed pallial neurons and relatively many neurons, which, despite very small brain volumes, might explain their high intelligence. The evolution of a syntactical and grammatical language in humans most probably has served as an additional intelligence amplifier, which may have happened in songbirds and psittacids in a convergent manner. © 2015 The Author(s).

  7. Multiple Small Diameter Drillings Increase Femoral Neck Stability Compared with Single Large Diameter Femoral Head Core Decompression Technique for Avascular Necrosis of the Femoral Head.

    PubMed

    Brown, Philip J; Mannava, Sandeep; Seyler, Thorsten M; Plate, Johannes F; Van Sikes, Charles; Stitzel, Joel D; Lang, Jason E

    2016-10-26

    Femoral head core decompression is an efficacious joint-preserving procedure for treatment of early stage avascular necrosis. However, postoperative fractures have been described which may be related to the decompression technique used. Femoral head decompressions were performed on 12 matched human cadaveric femora comparing large 8mm single bore versus multiple 3mm small drilling techniques. Ultimate failure strength of the femora was tested using a servo-hydraulic material testing system. Ultimate load to failure was compared between the different decompression techniques using two paired ANCOVA linear regression models. Prior to biomechanical testing and after the intervention, volumetric bone mineral density was determined using quantitative computed tomography to account for variation between cadaveric samples and to assess the amount of bone disruption by the core decompression. Core decompression, using the small diameter bore and multiple drilling technique, withstood significantly greater load prior to failure compared with the single large bore technique after adjustment for bone mineral density (p< 0.05). The 8mm single bore technique removed a significantly larger volume of bone compared to the 3mm multiple drilling technique (p< 0.001). However, total fracture energy was similar between the two core decompression techniques. When considering core decompression for the treatment of early stage avascular necrosis, the multiple small bore technique removed less bone volume, thereby potentially leading to higher load to failure.

  8. Impact of Use of Smaller Volume, Smaller Vacuum Blood Collection Tubes on Hemolysis in Emergency Department Blood Samples.

    PubMed

    Phelan, Michael P; Reineks, Edmunds Z; Berriochoa, Jacob P; Schold, Jesse D; Hustey, Fredric M; Chamberlin, Janelle; Kovach, Annmarie

    2017-10-01

    Hemolyzed blood samples commonly occur in hospital emergency departments (EDs). Our objective was to determine whether replacing standard large-volume/high-vacuum sample tubes with low-volume/low-vacuum tubes would significantly affect ED hemolysis. This was a prospective intervention of the use of small-volume/vacuum collection tubes. We evaluated all potassium samples in ED patients and associated hemolysis. We used χ2 tests to compare hemolysis incidence prior to and following utilization of small tubes for chemistry collection. There were 35,481 blood samples collected during the study period. Following implementation of small-volume tubes, overall hemolysis decreased from a baseline of 11.8% to 2.9% (P < .001) with corresponding reductions in hemolysis with comment (8.95% vs 1.99%; P < .001) gross hemolysis (2.84% vs 0.90%; P < .007). This work demonstrates that significant improvements in ED hemolysis can be achieved by utilization of small-volume/vacuum sample collection tubes. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  9. Small Bowel Dose Parameters Predicting Grade ≥3 Acute Toxicity in Rectal Cancer Patients Treated With Neoadjuvant Chemoradiation: An Independent Validation Study Comparing Peritoneal Space Versus Small Bowel Loop Contouring Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Banerjee, Robyn, E-mail: robynbanerjee@gmail.com; Chakraborty, Santam; Nygren, Ian

    Purpose: To determine whether volumes based on contours of the peritoneal space can be used instead of individual small bowel loops to predict for grade ≥3 acute small bowel toxicity in patients with rectal cancer treated with neoadjuvant chemoradiation therapy. Methods and Materials: A standardized contouring method was developed for the peritoneal space and retrospectively applied to the radiation treatment plans of 67 patients treated with neoadjuvant chemoradiation therapy for rectal cancer. Dose-volume histogram (DVH) data were extracted and analyzed against patient toxicity. Receiver operating characteristic analysis and logistic regression were carried out for both contouring methods. Results: Grade ≥3more » small bowel toxicity occurred in 16% (11/67) of patients in the study. A highly significant dose-volume relationship between small bowel irradiation and acute small bowel toxicity was supported by the use of both small bowel loop and peritoneal space contouring techniques. Receiver operating characteristic analysis demonstrated that, for both contouring methods, the greatest sensitivity for predicting toxicity was associated with the volume receiving between 15 and 25 Gy. Conclusion: DVH analysis of peritoneal space volumes accurately predicts grade ≥3 small bowel toxicity in patients with rectal cancer receiving neoadjuvant chemoradiation therapy, suggesting that the contours of the peritoneal space provide a reasonable surrogate for the contours of individual small bowel loops. The study finds that a small bowel V15 less than 275 cc and a peritoneal space V15 less than 830 cc are associated with a less than 10% risk of grade ≥3 acute toxicity.« less

  10. Homo naledi, a new species of the genus Homo from the Dinaledi Chamber, South Africa.

    PubMed

    Berger, Lee R; Hawks, John; de Ruiter, Darryl J; Churchill, Steven E; Schmid, Peter; Delezene, Lucas K; Kivell, Tracy L; Garvin, Heather M; Williams, Scott A; DeSilva, Jeremy M; Skinner, Matthew M; Musiba, Charles M; Cameron, Noel; Holliday, Trenton W; Harcourt-Smith, William; Ackermann, Rebecca R; Bastir, Markus; Bogin, Barry; Bolter, Debra; Brophy, Juliet; Cofran, Zachary D; Congdon, Kimberly A; Deane, Andrew S; Dembo, Mana; Drapeau, Michelle; Elliott, Marina C; Feuerriegel, Elen M; Garcia-Martinez, Daniel; Green, David J; Gurtov, Alia; Irish, Joel D; Kruger, Ashley; Laird, Myra F; Marchi, Damiano; Meyer, Marc R; Nalla, Shahed; Negash, Enquye W; Orr, Caley M; Radovcic, Davorka; Schroeder, Lauren; Scott, Jill E; Throckmorton, Zachary; Tocheri, Matthew W; VanSickle, Caroline; Walker, Christopher S; Wei, Pianpian; Zipfel, Bernhard

    2015-09-10

    Homo naledi is a previously-unknown species of extinct hominin discovered within the Dinaledi Chamber of the Rising Star cave system, Cradle of Humankind, South Africa. This species is characterized by body mass and stature similar to small-bodied human populations but a small endocranial volume similar to australopiths. Cranial morphology of H. naledi is unique, but most similar to early Homo species including Homo erectus, Homo habilis or Homo rudolfensis. While primitive, the dentition is generally small and simple in occlusal morphology. H. naledi has humanlike manipulatory adaptations of the hand and wrist. It also exhibits a humanlike foot and lower limb. These humanlike aspects are contrasted in the postcrania with a more primitive or australopith-like trunk, shoulder, pelvis and proximal femur. Representing at least 15 individuals with most skeletal elements repeated multiple times, this is the largest assemblage of a single species of hominins yet discovered in Africa.

  11. Effects of hydration on steric and electric charge-induced interstitial volume exclusion--a model.

    PubMed

    Øien, Alf H; Justad, Sigrid R; Tenstad, Olav; Wiig, Helge

    2013-09-03

    The presence of collagen and charged macromolecules like glycosaminoglycans (GAGs) in the interstitial space limits the space available for plasma proteins and other macromolecules. This phenomenon, known as interstitial exclusion, is of importance for interstitial fluid volume regulation. Physical/mathematical models are presented for calculating the exclusion of electrically charged and neutral macromolecules that equilibrate in the interstitium under various degrees of hydration. Here, a central hypothesis is that the swelling of highly electrically charged GAGs with increased hydration shields parts of the neutral collagen of the interstitial matrix from interacting with electrically charged macromolecules, such that exclusion of charged macromolecules exhibits change due to steric and charge effects. GAGs are also thought to allow relatively small neutral, but also charged macromolecules neutralized by a very high ionic strength, diffuse into the interior of GAGs, whereas larger macromolecules may not. Thus, in the model, relatively small electrically charged macromolecules, such as human serum albumin, and larger neutral macromolecules such as IgG, will have quite similar total volume exclusion properties in the interstitium. Our results are in agreement with ex vivo and in vivo experiments, and suggest that the charge of GAGs or macromolecular drugs may be targeted to increase the tissue uptake of macromolecular therapeutic agents. Copyright © 2013 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  12. Optimal ventilation of the anesthetized pediatric patient.

    PubMed

    Feldman, Jeffrey M

    2015-01-01

    Mechanical ventilation of the pediatric patient is challenging because small changes in delivered volume can be a significant fraction of the intended tidal volume. Anesthesia ventilators have traditionally been poorly suited to delivering small tidal volumes accurately, and pressure-controlled ventilation has become used commonly when caring for pediatric patients. Modern anesthesia ventilators are designed to deliver small volumes accurately to the patient's airway by compensating for the compliance of the breathing system and delivering tidal volume independent of fresh gas flow. These technology advances provide the opportunity to implement a lung-protective ventilation strategy in the operating room based upon control of tidal volume. This review will describe the capabilities of the modern anesthesia ventilator and the current understanding of lung-protective ventilation. An optimal approach to mechanical ventilation for the pediatric patient is described, emphasizing the importance of using bedside monitors to optimize the ventilation strategy for the individual patient.

  13. Endoclips vs large or small-volume epinephrine in peptic ulcer recurrent bleeding

    PubMed Central

    Ljubicic, Neven; Budimir, Ivan; Biscanin, Alen; Nikolic, Marko; Supanc, Vladimir; Hrabar, Davor; Pavic, Tajana

    2012-01-01

    AIM: To compare the recurrent bleeding after endoscopic injection of different epinephrine volumes with hemoclips in patients with bleeding peptic ulcer. METHODS: Between January 2005 and December 2009, 150 patients with gastric or duodenal bleeding ulcer with major stigmata of hemorrhage and nonbleeding visible vessel in an ulcer bed (Forrest IIa) were included in the study. Patients were randomized to receive a small-volume epinephrine group (15 to 25 mL injection group; Group 1, n = 50), a large-volume epinephrine group (30 to 40 mL injection group; Group 2, n = 50) and a hemoclip group (Group 3, n = 50). The rate of recurrent bleeding, as the primary outcome, was compared between the groups of patients included in the study. Secondary outcomes compared between the groups were primary hemostasis rate, permanent hemostasis, need for emergency surgery, 30 d mortality, bleeding-related deaths, length of hospital stay and transfusion requirements. RESULTS: Initial hemostasis was obtained in all patients. The rate of early recurrent bleeding was 30% (15/50) in the small-volume epinephrine group (Group 1) and 16% (8/50) in the large-volume epinephrine group (Group 2) (P = 0.09). The rate of recurrent bleeding was 4% (2/50) in the hemoclip group (Group 3); the difference was statistically significant with regard to patients treated with either small-volume or large-volume epinephrine solution (P = 0.0005 and P = 0.045, respectively). Duration of hospital stay was significantly shorter among patients treated with hemoclips than among patients treated with epinephrine whereas there were no differences in transfusion requirement or even 30 d mortality between the groups. CONCLUSION: Endoclip is superior to both small and large volume injection of epinephrine in the prevention of recurrent bleeding in patients with peptic ulcer. PMID:22611315

  14. Ultrasound measurement of transcranial distance during head-down tilt

    NASA Technical Reports Server (NTRS)

    Torikoshi, S.; Wilson, M. H.; Ballard, R. E.; Watenpaugh, D. E.; Murthy, G.; Yost, W. T.; Cantrell, J. H.; Chang, D. S.; Hargens, A. R.

    1995-01-01

    Exposure to microgravity elevates blood pressure and flow in the head, which may increase intracranial volume (ICV) and intracranial pressure (ICP). Rhesus monkeys exposed to simulated microgravity in the form of 6 degree head-down tilt (HDT) experience elevated ICP. With humans, twenty-four hours of 6 degree HDT bed rest increases cerebral blood flow velocity relative to pre-HDT upright posture. Humans exposed to acute 6 degree HDT experiments increased ICP, measured with the tympanic membrane displacement (TMD) technique. Other studies suggest that increased ICP in humans and cats causes measurable cranial bone movement across the sagittal suture. Due to the slightly compliant nature of the cranium, elevation of the ICP will increase ICV and transcranial distance. Currently, several non-invasive approaches to monitor ICP are being investigated. Such techniques include TMD and modal analysis of the skull. TMD may not be reliable over a large range of ICP and neither method is capable of measuring the small changes in pressure. Ultrasound, however, may reliably measure small distance changes that accompany ICP fluctuations. The purpose of our study was to develop and evaluate an ultrasound technique to measure transcranial distance changes during HDT.

  15. Pulsed Direct Current Electrospray: Enabling Systematic Analysis of Small Volume Sample by Boosting Sample Economy.

    PubMed

    Wei, Zhenwei; Xiong, Xingchuang; Guo, Chengan; Si, Xingyu; Zhao, Yaoyao; He, Muyi; Yang, Chengdui; Xu, Wei; Tang, Fei; Fang, Xiang; Zhang, Sichun; Zhang, Xinrong

    2015-11-17

    We had developed pulsed direct current electrospray ionization mass spectrometry (pulsed-dc-ESI-MS) for systematically profiling and determining components in small volume sample. Pulsed-dc-ESI utilized constant high voltage to induce the generation of single polarity pulsed electrospray remotely. This method had significantly boosted the sample economy, so as to obtain several minutes MS signal duration from merely picoliter volume sample. The elongated MS signal duration enable us to collect abundant MS(2) information on interested components in a small volume sample for systematical analysis. This method had been successfully applied for single cell metabolomics analysis. We had obtained 2-D profile of metabolites (including exact mass and MS(2) data) from single plant and mammalian cell, concerning 1034 components and 656 components for Allium cepa and HeLa cells, respectively. Further identification had found 162 compounds and 28 different modification groups of 141 saccharides in a single Allium cepa cell, indicating pulsed-dc-ESI a powerful tool for small volume sample systematical analysis.

  16. Using Hematology Data from Malaria Vaccine Research Trials in Humans and Rhesus Macaques (Macaca mulatta) To Guide Volume Limits for Blood Withdrawal.

    PubMed

    Hegge, Sara R; Hickey, Bradley W; Mcgrath, Shannon M; Stewart, V Ann

    2016-12-01

    Guidelines on safe volume limits for blood collection from research participants in both humans and laboratory animals vary widely between institutions. The main adverse event that may be encountered in large blood volume withdrawal is iron-deficiency anemia. Monitoring various parameters in a standard blood panel may help to prevent this outcome. To this end, we analyzed the Hgb and MCV values from 43 humans and 46 macaques in malaria vaccine research trials. Although the percentage of blood volume removed was greater for macaques than humans, macaques demonstrated an overall increase of MCV over time, indicating the ability to respond appropriately to frequent volume withdrawals. In contrast, humans showed a consistent declining trend in MCV. These declines in human MCV and Hgb were significant from the beginning to end of the study despite withdrawals that were smaller than recommended volume limits. Limiting the volume withdrawn to no more than 12.5% seemed to be sufficient for macaques, and at 14% or more individual animals tended to fail to respond appropriately to large-volume blood loss, as demonstrated by a decrease in MCV. The overall positive erythropoietic response seen in macaques was likely due to the controlled, iron-fortified diet they received. The lack of erythropoietic response in the human subjects may warrant iron supplementation or reconsideration of current blood volume withdrawal guidelines.

  17. Small Business Management Volume III: Curriculum. An Adult Education Program.

    ERIC Educational Resources Information Center

    Persons, Edgar A.; Swanson, Gordon I.

    The small business management adult education program outlined in this curriculum guide is designed to help small business entrepreneurs solve their business management problems and attain the goals they have established for their businesses and their families. (An instructor's manual and practice problems are in separate volumes.) The 3-year…

  18. 40 CFR 80.250 - How is the small refiner sulfur baseline and volume determined?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 17 2012-07-01 2012-07-01 false How is the small refiner sulfur... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Sulfur Hardship Provisions § 80.250 How is the small refiner sulfur baseline and volume determined? (a)(1) The...

  19. 40 CFR 80.250 - How is the small refiner sulfur baseline and volume determined?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 16 2011-07-01 2011-07-01 false How is the small refiner sulfur... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Sulfur Hardship Provisions § 80.250 How is the small refiner sulfur baseline and volume determined? (a)(1) The...

  20. 40 CFR 80.250 - How is the small refiner sulfur baseline and volume determined?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 17 2014-07-01 2014-07-01 false How is the small refiner sulfur... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Sulfur Hardship Provisions § 80.250 How is the small refiner sulfur baseline and volume determined? (a)(1) The...

  1. 40 CFR 80.250 - How is the small refiner sulfur baseline and volume determined?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 17 2013-07-01 2013-07-01 false How is the small refiner sulfur... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Sulfur Hardship Provisions § 80.250 How is the small refiner sulfur baseline and volume determined? (a)(1) The...

  2. 40 CFR 80.250 - How is the small refiner sulfur baseline and volume determined?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false How is the small refiner sulfur... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Sulfur Hardship Provisions § 80.250 How is the small refiner sulfur baseline and volume determined? (a)(1) The...

  3. NASA-STD-3001, Space Flight Human-System Standard and the Human Integration Design Handbook

    NASA Technical Reports Server (NTRS)

    Whitmore, Mihriban; Boyer, Jennifer; Holubec, Keith

    2012-01-01

    NASA-STD-3001 Space Flight Human-System Standard Volume 1, Crew Health, Volume 2, Human Factors, Habitability and Environmental Health, and the Human Integration Design Handbook (HIDH) have replaced the Man-Systems Integration Standards (MSIS), NASA-STD-3000. For decades, NASA-STD-3000 was a significant contribution to human spaceflight programs and to human-systems integration. However, with research program and project results being realized, advances in technology, and the availability of new information in a variety of topic areas, the time had arrived to update this extensive suite of standards and design information. NASA-STD-3001, Volume 2 contains the Agency level standards from the human and environmental factors disciplines that ensure human spaceflight operations are performed safely, efficiently, and effectively. The HIDH is organized in the same sequence and serves as the companion document to NASA-STD-3001, Volume 2, providing a compendium of human spaceflight history and knowledge. The HIDH is intended to aid interpretation of NASA-STD-3001, Volume 2 standards and to provide guidance for requirement writers and vehicle and habitat designers. Keywords Human Factors, Standards, Environmental Factors, NASA

  4. Assessment of regional ventilation and deformation using 4D-CT imaging for healthy human lungs during tidal breathing

    PubMed Central

    Jahani, Nariman; Choi, Jiwoong; Iyer, Krishna; Hoffman, Eric A.

    2015-01-01

    This study aims to assess regional ventilation, nonlinearity, and hysteresis of human lungs during dynamic breathing via image registration of four-dimensional computed tomography (4D-CT) scans. Six healthy adult humans were studied by spiral multidetector-row CT during controlled tidal breathing as well as during total lung capacity and functional residual capacity breath holds. Static images were utilized to contrast static vs. dynamic (deep vs. tidal) breathing. A rolling-seal piston system was employed to maintain consistent tidal breathing during 4D-CT spiral image acquisition, providing required between-breath consistency for physiologically meaningful reconstructed respiratory motion. Registration-derived variables including local air volume and anisotropic deformation index (ADI, an indicator of preferential deformation in response to local force) were employed to assess regional ventilation and lung deformation. Lobar distributions of air volume change during tidal breathing were correlated with those of deep breathing (R2 ≈ 0.84). Small discrepancies between tidal and deep breathing were shown to be likely due to different distributions of air volume change in the left and the right lungs. We also demonstrated an asymmetric characteristic of flow rate between inhalation and exhalation. With ADI, we were able to quantify nonlinearity and hysteresis of lung deformation that can only be captured in dynamic images. Nonlinearity quantified by ADI is greater during inhalation, and it is stronger in the lower lobes (P < 0.05). Lung hysteresis estimated by the difference of ADI between inhalation and exhalation is more significant in the right lungs than that in the left lungs. PMID:26316512

  5. Gas pressure assisted microliquid-liquid extraction coupled online to direct infusion mass spectrometry: a new automated screening platform for bioanalysis.

    PubMed

    Raterink, Robert-Jan; Witkam, Yoeri; Vreeken, Rob J; Ramautar, Rawi; Hankemeier, Thomas

    2014-10-21

    In the field of bioanalysis, there is an increasing demand for miniaturized, automated, robust sample pretreatment procedures that can be easily connected to direct-infusion mass spectrometry (DI-MS) in order to allow the high-throughput screening of drugs and/or their metabolites in complex body fluids like plasma. Liquid-Liquid extraction (LLE) is a common sample pretreatment technique often used for complex aqueous samples in bioanalysis. Despite significant developments that have been made in automated and miniaturized LLE procedures, fully automated LLE techniques allowing high-throughput bioanalytical studies on small-volume samples using direct infusion mass spectrometry, have not been matured yet. Here, we introduce a new fully automated micro-LLE technique based on gas-pressure assisted mixing followed by passive phase separation, coupled online to nanoelectrospray-DI-MS. Our method was characterized by varying the gas flow and its duration through the solvent mixture. For evaluation of the analytical performance, four drugs were spiked to human plasma, resulting in highly acceptable precision (RSD down to 9%) and linearity (R(2) ranging from 0.990 to 0.998). We demonstrate that our new method does not only allow the reliable extraction of analytes from small sample volumes of a few microliters in an automated and high-throughput manner, but also performs comparable or better than conventional offline LLE, in which the handling of small volumes remains challenging. Finally, we demonstrate the applicability of our method for drug screening on dried blood spots showing excellent linearity (R(2) of 0.998) and precision (RSD of 9%). In conclusion, we present the proof of principe of a new high-throughput screening platform for bioanalysis based on a new automated microLLE method, coupled online to a commercially available nano-ESI-DI-MS.

  6. Development of a bio-magnetic measurement system and sensor configuration analysis for rats

    NASA Astrophysics Data System (ADS)

    Kim, Ji-Eun; Kim, In-Seon; Kim, Kiwoong; Lim, Sanghyun; Kwon, Hyukchan; Kang, Chan Seok; Ahn, San; Yu, Kwon Kyu; Lee, Yong-Ho

    2017-04-01

    Magnetoencephalography (MEG) based on superconducting quantum interference devices enables the measurement of very weak magnetic fields (10-1000 fT) generated from the human or animal brain. In this article, we introduce a small MEG system that we developed specifically for use with rats. Our system has the following characteristics: (1) variable distance between the pick-up coil and outer Dewar bottom (˜5 mm), (2) small pick-up coil (4 mm) for high spatial resolution, (3) good field sensitivity (45 ˜ 80 fT /cm/√{Hz} ) , (4) the sensor interval satisfies the Nyquist spatial sampling theorem, and (5) small source localization error for the region to be investigated. To reduce source localization error, it is necessary to establish an optimal sensor layout. To this end, we simulated confidence volumes at each point on a grid on the surface of a virtual rat head. In this simulation, we used locally fitted spheres as model rat heads. This enabled us to consider more realistic volume currents. We constrained the model such that the dipoles could have only four possible orientations: the x- and y-axes from the original coordinates, and two tangentially layered dipoles (local x- and y-axes) in the locally fitted spheres. We considered the confidence volumes according to the sensor layout and dipole orientation and positions. We then conducted a preliminary test with a 4-channel MEG system prior to manufacturing the multi-channel system. Using the 4-channel MEG system, we measured rat magnetocardiograms. We obtained well defined P-, QRS-, and T-waves in rats with a maximum value of 15 pT/cm. Finally, we measured auditory evoked fields and steady state auditory evoked fields with maximum values 400 fT/cm and 250 fT/cm, respectively.

  7. Supraclavicular Skin Temperature as a Measure of 18F-FDG Uptake by BAT in Human Subjects

    PubMed Central

    van der Linden, Rianne A. D.; Pereira Arias-Bouda, Lenka; Smit, Frits; Verberne, Hein J.; van Marken Lichtenbelt, Wouter D.

    2014-01-01

    Background Brown adipose tissue (BAT) has emerged as a novel player in energy homeostasis in humans and is considered a potential new target for combating obesity and related diseases. The current ‘gold standard’ for quantification of BAT volume and activity is cold-induced 18F-FDG uptake in BAT. However, use of this technique is limited by cost and radiation exposure. Given the fact that BAT is a thermogenic tissue, mainly located in the supraclavicular region, the aim of the current study was to investigate whether cold-induced supraclavicular skin temperature and core body temperature may be alternative markers of BAT activation in humans. Subjects/Methods BAT volume and activity were measured in 24 healthy lean adolescent males (mean age 24.1±0.8 years), using cold-induced 18F-FDG uptake with PET-CT. Core body temperature was measured continuously in the small intestine with use of an ingestible telemetric capsule and skin temperature was measured by eighteen wireless iButtons attached to the skin following ISO-defined locations. Results Proximal and distal (hand/feet) skin temperatures markedly decreased upon cold exposure, while supraclavicular skin temperature significantly increased (35.2±0.1 vs. 35.5±0.1°C, p = 0.001). Furthermore, cold-induced supraclavicular skin temperature positively correlated with both total (R2 = 0.28, P = 0.010) and clavicular BAT volume (R2 = 0.20, P = 0.030) and clavicular SUVmax (R2 = 0.27, P = 0.010), while core body temperature did not. Conclusions Supraclavicular skin temperature as measured by iButtons may have predictive value for BAT detection in adult humans. This is highly desirable considering the increasing interest in pharmacological interventions to stimulate BAT in human subjects. Trial Registration NTR 2473 PMID:24922545

  8. Cortical lamina-dependent blood volume changes in human brain at 7 T.

    PubMed

    Huber, Laurentius; Goense, Jozien; Kennerley, Aneurin J; Trampel, Robert; Guidi, Maria; Reimer, Enrico; Ivanov, Dimo; Neef, Nicole; Gauthier, Claudine J; Turner, Robert; Möller, Harald E

    2015-02-15

    Cortical layer-dependent high (sub-millimeter) resolution functional magnetic resonance imaging (fMRI) in human or animal brain can be used to address questions regarding the functioning of cortical circuits, such as the effect of different afferent and efferent connectivities on activity in specific cortical layers. The sensitivity of gradient echo (GE) blood oxygenation level-dependent (BOLD) responses to large draining veins reduces its local specificity and can render the interpretation of the underlying laminar neural activity impossible. The application of the more spatially specific cerebral blood volume (CBV)-based fMRI in humans has been hindered by the low sensitivity of the noninvasive modalities available. Here, a vascular space occupancy (VASO) variant, adapted for use at high field, is further optimized to capture layer-dependent activity changes in human motor cortex at sub-millimeter resolution. Acquired activation maps and cortical profiles show that the VASO signal peaks in gray matter at 0.8-1.6mm depth, and deeper compared to the superficial and vein-dominated GE-BOLD responses. Validation of the VASO signal change versus well-established iron-oxide contrast agent based fMRI methods in animals showed the same cortical profiles of CBV change, after normalization for lamina-dependent baseline CBV. In order to evaluate its potential of revealing small lamina-dependent signal differences due to modulations of the input-output characteristics, layer-dependent VASO responses were investigated in the ipsilateral hemisphere during unilateral finger tapping. Positive activation in ipsilateral primary motor cortex and negative activation in ipsilateral primary sensory cortex were observed. This feature is only visible in high-resolution fMRI where opposing sides of a sulcus can be investigated independently because of a lack of partial volume effects. Based on the results presented here, we conclude that VASO offers good reproducibility, high sensitivity and lower sensitivity than GE-BOLD to changes in larger vessels, making it a valuable tool for layer-dependent fMRI studies in humans. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Experimental evaluation of boron neutron capture therapy of human breast carcinoma implanted on nude mice

    NASA Astrophysics Data System (ADS)

    Bose, Satya Ranjan

    2000-06-01

    An in-pool small animal irradiation neutron tube (SAINT) facility was designed, constructed and installed at the University of Virginia Nuclear Research Reactor (UVAR). Thermal neutron flux profiles were measured by foil activation analysis (gold) and verified with DORT and MCNP computer code models. The gamma-ray absorbed dose in the neutron-gamma mixed field was determined from TLD measurements. The SAINT thermal neutron flux was used to investigate the well characterized human breast cancer cell line MCF-7B on both in-vitro samples and in- vivo animal subjects. Boronophenylalanine (BPA enriched in 95% 10B) was used as a neutron capturing agent. The in-vitro response of MCF-7B human breast carcinoma cells to BPA in a mixed field of neutron-gamma radiation or pure 60Co gamma radiation was investigated. The best result (lowest surviving fraction) was observed in cell cultures pre-incubated with BPA and given the neutron irradiation. The least effective treatment consisted of 60Co irradiation only. Immunologically deficient nude mice were inoculated subcutaneously with human breast cancer MCF-7B cells and estradiol pellets (to support tumor growth). The tumor volume in the mouse control group increased over time, as expected. The group of mice exposed only to neutron treatment exhibited initial tumor volume reduction lasting until 35 days following the treatment, followed by renewed tumor growth. Both groups given BPA plus neutron treatment showed continuous reduction in tumor volume over the 55-day observation period. The group given the higher BPA concentration showed the best tumor reduction response. The results on both in-vitro and in-vivo studies showed increased cell killing with BPA, substantiating the incorporation of BPA into the tumor or cell line. Therefore, BNCT may be a possible choice for the treatment of human breast carcinoma. However, prior to the initiation of any clinical studies, it is necessary to determine the therapeutic efficacy in a large animal model.

  10. Infrared astronomical satellite (IRAS) catalogs and atlases. Volume 7: The small scale structure catalog

    NASA Technical Reports Server (NTRS)

    Helou, George (Editor); Walker, D. W. (Editor)

    1988-01-01

    The Infrared Astronomical Satellite (IRAS) was launched January 26, 1983. During its 300-day mission, it surveyed over 96 pct of the celestial sphere at four infrared wavelengths, centered approximately at 12, 25, 60, and 100 microns. Volume 1 describes the instrument, the mission, and the data reduction process. Volumes 2 through 6 present the observations of the approximately 245,000 individual point sources detected by IRAS; each volume gives sources within a specified range of declination. Volume 7 gives the observations of the approximately 16,000 sources spatially resolved by IRAS and smaller than 8'. This is Volume 7, The Small Scale Structure Catalog.

  11. Compulsive sexual behavior: Prefrontal and limbic volume and interactions.

    PubMed

    Schmidt, Casper; Morris, Laurel S; Kvamme, Timo L; Hall, Paula; Birchard, Thaddeus; Voon, Valerie

    2017-03-01

    Compulsive sexual behaviors (CSB) are relatively common and associated with significant personal and social dysfunction. The underlying neurobiology is still poorly understood. The present study examines brain volumes and resting state functional connectivity in CSB compared with matched healthy volunteers (HV). Structural MRI (MPRAGE) data were collected in 92 subjects (23 CSB males and 69 age-matched male HV) and analyzed using voxel-based morphometry. Resting state functional MRI data using multi-echo planar sequence and independent components analysis (ME-ICA) were collected in 68 subjects (23 CSB subjects and 45 age-matched HV). CSB subjects showed greater left amygdala gray matter volumes (small volume corrected, Bonferroni adjusted P < 0.01) and reduced resting state functional connectivity between the left amygdala seed and bilateral dorsolateral prefrontal cortex (whole brain, cluster corrected FWE P < 0.05) compared with HV. CSB is associated with elevated volumes in limbic regions relevant to motivational salience and emotion processing, and impaired functional connectivity between prefrontal control regulatory and limbic regions. Future studies should aim to assess longitudinal measures to investigate whether these findings are risk factors that predate the onset of the behaviors or are consequences of the behaviors. Hum Brain Mapp 38:1182-1190, 2017. © 2016 Wiley Periodicals, Inc. © 2016 The Authors Human Brain Mapping Published by Wiley Periodicals, Inc.

  12. Archimedes Revisited: A Faster, Better, Cheaper Method of Accurately Measuring the Volume of Small Objects

    ERIC Educational Resources Information Center

    Hughes, Stephen W.

    2005-01-01

    A little-known method of measuring the volume of small objects based on Archimedes' principle is described, which involves suspending an object in a water-filled container placed on electronic scales. The suspension technique is a variation on the hydrostatic weighing technique used for measuring volume. The suspension method was compared with two…

  13. The Defense Science Board 1997 Summer Study Task Force on DoD Responses to Transnational Threats; Volume 1 - Final Report.

    DTIC Science & Technology

    1997-10-01

    loss of human life - both theirs and ours - their initiatives present a formidable challenge to long-term national security. Even a small nation with...the chemical release killed a dozen people, well over 5,000 were injured and the release had the potential for far more devastating loss of life. In...individuals or groups to produce major damage and loss of life exists today. Events that we have already witnessed could well have resulted in far graver

  14. Antarctic icebergs distributions 1992-2014

    NASA Astrophysics Data System (ADS)

    Tournadre, J.; Bouhier, N.; Girard-Ardhuin, F.; Rémy, F.

    2016-01-01

    Basal melting of floating ice shelves and iceberg calving constitute the two almost equal paths of freshwater flux between the Antarctic ice cap and the Southern Ocean. The largest icebergs (>100 km2) transport most of the ice volume but their basal melting is small compared to their breaking into smaller icebergs that constitute thus the major vector of freshwater. The archives of nine altimeters have been processed to create a database of small icebergs (<8 km2) within open water containing the positions, sizes, and volumes spanning the 1992-2014 period. The intercalibrated monthly ice volumes from the different altimeters have been merged in a homogeneous 23 year climatology. The iceberg size distribution, covering the 0.1-10,000 km2 range, estimated by combining small and large icebergs size measurements follows well a power law of slope -1.52 ± 0.32 close to the -3/2 laws observed and modeled for brittle fragmentation. The global volume of ice and its distribution between the ocean basins present a very strong interannual variability only partially explained by the number of large icebergs. Indeed, vast zones of the Southern Ocean free of large icebergs are largely populated by small iceberg drifting over thousands of kilometers. The correlation between the global small and large icebergs volumes shows that small icebergs are mainly generated by large ones breaking. Drifting and trapping by sea ice can transport small icebergs for long period and distances. Small icebergs act as an ice diffuse process along large icebergs trajectories while sea ice trapping acts as a buffer delaying melting.

  15. Canine spontaneous glioma: A translational model system for convection-enhanced delivery

    PubMed Central

    Dickinson, Peter J.; LeCouteur, Richard A.; Higgins, Robert J.; Bringas, John R.; Larson, Richard F.; Yamashita, Yoji; Krauze, Michal T.; Forsayeth, John; Noble, Charles O.; Drummond, Daryl C.; Kirpotin, Dmitri B.; Park, John W.; Berger, Mitchel S.; Bankiewicz, Krystof S.

    2010-01-01

    Canine spontaneous intracranial tumors bear striking similarities to their human tumor counterparts and have the potential to provide a large animal model system for more realistic validation of novel therapies typically developed in small rodent models. We used spontaneously occurring canine gliomas to investigate the use of convection-enhanced delivery (CED) of liposomal nanoparticles, containing topoisomerase inhibitor CPT-11. To facilitate visualization of intratumoral infusions by real-time magnetic resonance imaging (MRI), we included identically formulated liposomes loaded with Gadoteridol. Real-time MRI defined distribution of infusate within both tumor and normal brain tissues. The most important limiting factor for volume of distribution within tumor tissue was the leakage of infusate into ventricular or subarachnoid spaces. Decreased tumor volume, tumor necrosis, and modulation of tumor phenotype correlated with volume of distribution of infusate (Vd), infusion location, and leakage as determined by real-time MRI and histopathology. This study demonstrates the potential for canine spontaneous gliomas as a model system for the validation and development of novel therapeutic strategies for human brain tumors. Data obtained from infusions monitored in real time in a large, spontaneous tumor may provide information, allowing more accurate prediction and optimization of infusion parameters. Variability in Vd between tumors strongly suggests that real-time imaging should be an essential component of CED therapeutic trials to allow minimization of inappropriate infusions and accurate assessment of clinical outcomes. PMID:20488958

  16. 40 CFR 86.1838-01 - Small volume manufacturer certification procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... paragraph (c)(2). (i) Small volume in-use verification test vehicles may be procured from customers or may... miles, a manufacturer may demonstrate to the satisfaction of the Agency that, based on owner survey data...

  17. Age-related effects in the neocortical organization of chimpanzees: gray and white matter volume, cortical thickness, and gyrification.

    PubMed

    Autrey, Michelle M; Reamer, Lisa A; Mareno, Mary Catherine; Sherwood, Chet C; Herndon, James G; Preuss, Todd; Schapiro, Steve J; Hopkins, William D

    2014-11-01

    Among primates, humans exhibit the most profound degree of age-related brain volumetric decline in particular regions, such as the hippocampus and the frontal lobe. Recent studies have shown that our closest living relatives, the chimpanzees, experience little to no volumetric decline in gray and white matter over the adult lifespan. However, these previous studies were limited with a small sample of chimpanzees of the most advanced ages. In the present study, we sought to further test for potential age-related decline in cortical organization in chimpanzees by expanding the sample size of aged chimpanzees. We used the BrainVisa software to measure total brain volume, gray and white matter volumes, gray matter thickness, and gyrification index in a cross-sectional sample of 219 captive chimpanzees (8-53 years old), with 38 subjects being 40 or more years of age. Mean depth and cortical fold opening of 11 major sulci of the chimpanzee brains were also measured. We found that chimpanzees showed increased gyrification with age and a cubic relationship between age and white matter volume. For the association between age and sulcus depth and width, the results were mostly non-significant with the exception of one negative correlation between age and the fronto-orbital sulcus. In short, results showed that chimpanzees exhibit few age-related changes in global cortical organization, sulcus folding and sulcus width. These findings support previous studies and the theory that the age-related changes in the human brain is due to an extended lifespan. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Electrochemical attosyringe.

    PubMed

    Laforge, François O; Carpino, James; Rotenberg, Susan A; Mirkin, Michael V

    2007-07-17

    The ability to manipulate ultrasmall volumes of liquids is essential in such diverse fields as cell biology, microfluidics, capillary chromatography, and nanolithography. In cell biology, it is often necessary to inject material of high molecular weight (e.g., DNA, proteins) into living cells because their membranes are impermeable to such molecules. All techniques currently used for microinjection are plagued by two common problems: the relatively large injector size and volume of injected fluid, and poor control of the amount of injected material. Here we demonstrate the possibility of electrochemical control of the fluid motion that allows one to sample and dispense attoliter-to-picoliter (10(-18) to 10(-12) liter) volumes of either aqueous or nonaqueous solutions. By changing the voltage applied across the liquid/liquid interface, one can produce a sufficient force to draw solution inside a nanopipette and then inject it into an immobilized biological cell. A high success rate was achieved in injections of fluorescent dyes into cultured human breast cells. The injection of femtoliter-range volumes can be monitored by video microscopy, and current/resistance-based approaches can be used to control injections from very small pipettes. Other potential applications of the electrochemical syringe include fluid dispensing in nanolithography and pumping in microfluidic systems.

  19. Electrochemical attosyringe

    PubMed Central

    Laforge, François O.; Carpino, James; Rotenberg, Susan A.; Mirkin, Michael V.

    2007-01-01

    The ability to manipulate ultrasmall volumes of liquids is essential in such diverse fields as cell biology, microfluidics, capillary chromatography, and nanolithography. In cell biology, it is often necessary to inject material of high molecular weight (e.g., DNA, proteins) into living cells because their membranes are impermeable to such molecules. All techniques currently used for microinjection are plagued by two common problems: the relatively large injector size and volume of injected fluid, and poor control of the amount of injected material. Here we demonstrate the possibility of electrochemical control of the fluid motion that allows one to sample and dispense attoliter-to-picoliter (10−18 to 10−12 liter) volumes of either aqueous or nonaqueous solutions. By changing the voltage applied across the liquid/liquid interface, one can produce a sufficient force to draw solution inside a nanopipette and then inject it into an immobilized biological cell. A high success rate was achieved in injections of fluorescent dyes into cultured human breast cells. The injection of femtoliter-range volumes can be monitored by video microscopy, and current/resistance-based approaches can be used to control injections from very small pipettes. Other potential applications of the electrochemical syringe include fluid dispensing in nanolithography and pumping in microfluidic systems. PMID:17620612

  20. NASA Space Flight Human-System Standard Human Factors, Habitability, and Environmental Health

    NASA Technical Reports Server (NTRS)

    Holubec, Keith; Connolly, Janis

    2010-01-01

    This slide presentation reviews the history, and development of NASA-STD-3001, NASA Space Flight Human-System Standard Human Factors, Habitability, and Environmental Health, and the related Human Integration Design Handbook. Currently being developed from NASA-STD-3000, this project standard currently in review will be available in two volumes, (i.e., Volume 1 -- VCrew Health and Volume 2 -- Human Factors, Habitability, and Environmental Health) and the handbook will be both available as a pdf file and as a interactive website.

  1. Magnetic Resonance Imaging Quantification of Fasted State Colonic Liquid Pockets in Healthy Humans.

    PubMed

    Murray, Kathryn; Hoad, Caroline L; Mudie, Deanna M; Wright, Jeff; Heissam, Khaled; Abrehart, Nichola; Pritchard, Susan E; Al Atwah, Salem; Gowland, Penny A; Garnett, Martin C; Amidon, Gregory E; Spiller, Robin C; Amidon, Gordon L; Marciani, Luca

    2017-08-07

    The rate and extent of drug dissolution and absorption from solid oral dosage forms is highly dependent on the volume of liquid in the gastrointestinal tract (GIT). However, little is known about the time course of GIT liquid volumes after drinking a glass of water (8 oz), particularly in the colon, which is a targeted site for both locally and systemically acting drug products. Previous magnetic resonance imaging (MRI) studies offered novel insights on GIT liquid distribution in fasted humans in the stomach and small intestine, and showed that freely mobile liquid in the intestine collects in fairly distinct regions or "pockets". Based on this previous pilot data, we hypothesized that (1) it is possible to quantify the time course of the volume and number of liquid pockets in the undisturbed colon of fasted healthy humans following ingestion of 240 mL, using noninvasive MRI methods; (2) the amount of freely mobile water in the fasted human colon is of the order of only a few milliliters. Twelve healthy volunteers fasted overnight and underwent fasted abdominal MRI scans before drinking 240 mL (∼8 fluid ounces) of water. After ingesting the water they were scanned at frequent intervals for 2 h. The images were processed to quantify freely mobile water in the total and regional colon: ascending, transverse, and descending. The fasted colon contained (mean ± SEM) 11 ± 5 pockets of resting liquid with a total volume of 2 ± 1 mL (average). The colonic fluid peaked at 7 ± 4 mL 30 min after the water drink. This peak fluid was distributed in 17 ± 7 separate liquid pockets in the colon. The regional analysis showed that pockets of free fluid were found primarily in the ascending colon. The interindividual variability was very high; the subjects showed a range of number of colonic fluid pockets from 0 to 89 and total colonic freely mobile fluid volume from 0 to 49 mL. This is the first study measuring the time course of the number, regional location, and volume of pockets of freely mobile liquid in the undisturbed colon of fasted humans after ingestion of a glass of water. Novel insights into the colonic fluid environment will be particularly relevant to improve our understanding and design of the in vivo performance of controlled release formulations targeted to the colon. The in vivo quantitative information presented here can be input into physiologically based mechanistic models of dissolution and absorption, and can be used in the design and set up of novel in vitro performance tools predictive of the in vivo environment.

  2. Stochastic calculus of protein filament formation under spatial confinement

    NASA Astrophysics Data System (ADS)

    Michaels, Thomas C. T.; Dear, Alexander J.; Knowles, Tuomas P. J.

    2018-05-01

    The growth of filamentous aggregates from precursor proteins is a process of central importance to both normal and aberrant biology, for instance as the driver of devastating human disorders such as Alzheimer's and Parkinson's diseases. The conventional theoretical framework for describing this class of phenomena in bulk is based upon the mean-field limit of the law of mass action, which implicitly assumes deterministic dynamics. However, protein filament formation processes under spatial confinement, such as in microdroplets or in the cellular environment, show intrinsic variability due to the molecular noise associated with small-volume effects. To account for this effect, in this paper we introduce a stochastic differential equation approach for investigating protein filament formation processes under spatial confinement. Using this framework, we study the statistical properties of stochastic aggregation curves, as well as the distribution of reaction lag-times. Moreover, we establish the gradual breakdown of the correlation between lag-time and normalized growth rate under spatial confinement. Our results establish the key role of spatial confinement in determining the onset of stochasticity in protein filament formation and offer a formalism for studying protein aggregation kinetics in small volumes in terms of the kinetic parameters describing the aggregation dynamics in bulk.

  3. An inexpensive and portable microvolumeter for rapid evaluation of biological samples.

    PubMed

    Douglass, John K; Wcislo, William T

    2010-08-01

    We describe an improved microvolumeter (MVM) for rapidly measuring volumes of small biological samples, including live zooplankton, embryos, and small animals and organs. Portability and low cost make this instrument suitable for widespread use, including at remote field sites. Beginning with Archimedes' principle, which states that immersing an arbitrarily shaped sample in a fluid-filled container displaces an equivalent volume, we identified procedures that maximize measurement accuracy and repeatability across a broad range of absolute volumes. Crucial steps include matching the overall configuration to the size of the sample, using reflected light to monitor fluid levels precisely, and accounting for evaporation during measurements. The resulting precision is at least 100 times higher than in previous displacement-based methods. Volumes are obtained much faster than by traditional histological or confocal methods and without shrinkage artifacts due to fixation or dehydration. Calibrations using volume standards confirmed accurate measurements of volumes as small as 0.06 microL. We validated the feasibility of evaluating soft-tissue samples by comparing volumes of freshly dissected ant brains measured with the MVM and by confocal reconstruction.

  4. The Different Volume Effects of Small-Bowel Toxicity During Pelvic Irradiation Between Gynecologic Patients With and Without Abdominal Surgery: A Prospective Study With Computed Tomography-Based Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, E.-Y.; Graduate Institute of Clinical Medical Sciences, Chang Gung University College of Medicine, Kaohsiung, Taiwan; School of Traditional Chinese Medicine, Chang Gung University College of Medicine, Kaohsiung, Taiwan

    Purpose: To evaluate the effect of abdominal surgery on the volume effects of small-bowel toxicity during whole-pelvic irradiation in patients with gynecologic malignancies. Methods and Materials: From May 2003 through November 2006, 80 gynecologic patients without (Group I) or with (Group II) prior abdominal surgery were analyzed. We used a computed tomography (CT) planning system to measure the small-bowel volume and dosimetry. We acquired the range of small-bowel volume in 10% (V10) to 100% (V100) of dose, at 10% intervals. The onset and grade of diarrhea during whole-pelvic irradiation were recorded as small-bowel toxicity up to 39.6 Gy in 22more » fractions. Results: The volume effect of Grade 2-3 diarrhea existed from V10 to V100 in Group I patients and from V60 to V100 in Group II patients on univariate analyses. The V40 of Group I and the V100 of Group II achieved most statistical significance. The mean V40 was 281 {+-} 27 cm{sup 3} and 489 {+-} 34 cm{sup 3} (p < 0.001) in Group I patients with Grade 0-1 and Grade 2-3 diarrhea, respectively. The corresponding mean V100 of Group II patients was 56 {+-} 14 cm{sup 3} and 132 {+-} 19 cm{sup 3} (p = 0.003). Multivariate analyses revealed that V40 (p = 0.001) and V100 (p = 0.027) were independent factors for the development of Grade 2-3 diarrhea in Groups I and II, respectively. Conclusions: Gynecologic patients without and with abdominal surgery have different volume effects on small-bowel toxicity during whole-pelvic irradiation. Low-dose volume can be used as a predictive index of Grade 2 or greater diarrhea in patients without abdominal surgery. Full-dose volume is more important than low-dose volume for Grade 2 or greater diarrhea in patients with abdominal surgery.« less

  5. Measuring pedestrian volumes and conflicts. Volume 1, Pedestrian volume sampling

    DOT National Transportation Integrated Search

    1987-12-01

    This final report presents the findings, conclusions, and recommendations of the study conducted to develop a model to predict pedestrian volumes using small sampling schemes. This research produced four pedestrian volume prediction models (i.e., 1-,...

  6. In vivo label-free lymphangiography of cutaneous lymphatic vessels in human burn scars using optical coherence tomography

    PubMed Central

    Gong, Peijun; Es’haghian, Shaghayegh; Harms, Karl-Anton; Murray, Alexandra; Rea, Suzanne; Wood, Fiona M.; Sampson, David D.; McLaughlin, Robert A.

    2016-01-01

    We present an automated, label-free method for lymphangiography of cutaneous lymphatic vessels in humans in vivo using optical coherence tomography (OCT). This method corrects for the variation in OCT signal due to the confocal function and sensitivity fall-off of a spectral-domain OCT system and utilizes a single-scattering model to compensate for A-scan signal attenuation to enable reliable thresholding of lymphatic vessels. A segment-joining algorithm is then incorporated into the method to mitigate partial-volume effects with small vessels. The lymphatic vessel images are augmented with images of the blood vessel network, acquired from the speckle decorrelation with additional weighting to differentiate blood vessels from the observed high decorrelation in lymphatic vessels. We demonstrate the method with longitudinal scans of human burn scar patients undergoing ablative fractional laser treatment, showing the visualization of the cutaneous lymphatic and blood vessel networks. PMID:28018713

  7. Respiratory ultradian rhythms of mean and low frequencies: a comparative physiological approach.

    PubMed

    Stupfel, M; Pletan, Y

    1983-01-01

    Recent developments in human rhythmic respiratory pathology lead to this review of the literature for ultradian rhythms of middle and low frequencies, that is having periods longer than the usual respiratory rates, whose periods are seconds or fractions of seconds. Ultradian respiratory movements for respiratory periods (5 less than tau less than 50 min) have been reported in many species of small laboratory animals (mice, rats, guinea-pigs, rabbits, quails). Long-period respiratory rates (20 less than tau less than 90 min) have been found in human fetuses and infants. But they are more difficult to detect in human adults, except during sleep where they have been related to REM and NONREM activities. These respiratory rhythms of middle and low frequencies are supposed to result from dissipative energy structures related to surface-volume relationships, with interlocking chemical clocks, and to be relevant to a basic rest-activity cycle.

  8. Asymmetry of Radial and Symmetry of Tangential Neuronal Migration Pathways in Developing Human Fetal Brains

    PubMed Central

    Miyazaki, Yuta; Song, Jae W.; Takahashi, Emi

    2016-01-01

    The radial and tangential neural migration pathways are two major neuronal migration streams in humans that are critical during corticogenesis. Corticogenesis is a complex process of neuronal proliferation that is followed by neuronal migration and the formation of axonal connections. Existing histological assessments of these two neuronal migration pathways have limitations inherent to microscopic studies and are confined to small anatomic regions of interest (ROIs). Thus, little evidence is available about their three-dimensional (3-D) fiber pathways and development throughout the entire brain. In this study, we imaged and analyzed radial and tangential migration pathways in the whole human brain using high-angular resolution diffusion MR imaging (HARDI) tractography. We imaged ten fixed, postmortem fetal (17 gestational weeks (GW), 18 GW, 19 GW, three 20 GW, three 21 GW and 22 GW) and eight in vivo newborn (two 30 GW, 34 GW, 35 GW and four 40 GW) brains with no neurological/pathological conditions. We statistically compared the volume of the left and right radial and tangential migration pathways, and the volume of the radial migration pathways of the anterior and posterior regions of the brain. In specimens 22 GW or younger, the volume of radial migration pathways of the left hemisphere was significantly larger than that of the right hemisphere. The volume of posterior radial migration pathways was also larger when compared to the anterior pathways in specimens 22 GW or younger. In contrast, no significant differences were observed in the radial migration pathways of brains older than 22 GW. Moreover, our study did not identify any significant differences in volumetric laterality in the tangential migration pathways. These results suggest that these two neuronal migration pathways develop and regress differently, and radial neuronal migration varies regionally based on hemispheric and anterior-posterior laterality, potentially explaining regional differences in the amount of excitatory neurons that migrate along the radial scaffold. PMID:26834572

  9. Water reservoir characteristics derivation from pubicly available global elevation data

    NASA Astrophysics Data System (ADS)

    Van De Giesen, N.; van Bemmelen, C.; Mann, M.; de Ridder, M.; Gupta, V.; Rutten, M.

    2017-12-01

    In order to assess human impact on the global hydrological cycle, it is imperative to characterize all major man made reservoirs. One important characteristic is the relationship between the surface area of a reservoir and its stored water volume. Surface areas can readily be determined through optical and radar satellite remote sensing. Once the relationship between the surface area of a reservoir and its stored water volume is known, one can determine the stored volumes over time using remotely sensed surface areas. It has been known for some time that this relationship between surface and stored volume shows a very high level of regional consistency [1]. This implies that if one knows this relationship in a certain region, one can predict the same for any nearby reservoir. We have tried to exploit this fact by examining whether one can build virtual dams in the neighborhood of an existing dam to determine the general relationship between surface area and stored volume. We examined twelve reservoirs around the world and found, generally, very good results. Especially in geomorphologically homogeneous areas, the relationships could reliable be extrapolated over space. Even in very heterogeneous areas, the final results were acceptable and much better than generic relationships used so far. Finally, we have examined to what extent it is possible to select virtual dam sites automatically. The first results for this are promising and show that it may be possible to characterize most major dams in the world according to this approach. It is likely that there will be the need for human detection for a reasonable percentage. For these relatively rare case, some human micro-tasking may be the way forward. It is expected, however, that >90% of the worldś dams can be characterized automatically [1] Liebe, J., N. Van De Giesen, and Marc Andreini. "Estimation of small reservoir storage capacities in a semi-arid environment: A case study in the Upper East Region of Ghana." Physics and Chemistry of the Earth, Parts A/B/C 30, no. 6 (2005): 448-454.

  10. Therapeutic targeting and rapid mobilization of endosteal HSC using a small molecule integrin antagonist

    PubMed Central

    Cao, Benjamin; Zhang, Zhen; Grassinger, Jochen; Williams, Brenda; Heazlewood, Chad K.; Churches, Quentin I.; James, Simon A.; Li, Songhui; Papayannopoulou, Thalia; Nilsson, Susan K.

    2016-01-01

    The inherent disadvantages of using granulocyte colony-stimulating factor (G-CSF) for hematopoietic stem cell (HSC) mobilization have driven efforts to identify alternate strategies based on single doses of small molecules. Here, we show targeting α9β1/α4β1 integrins with a single dose of a small molecule antagonist (BOP (N-(benzenesulfonyl)-L-prolyl-L-O-(1-pyrrolidinylcarbonyl)tyrosine)) rapidly mobilizes long-term multi-lineage reconstituting HSC. Synergistic engraftment augmentation is observed when BOP is co-administered with AMD3100. Impressively, HSC in equal volumes of peripheral blood (PB) mobilized with this combination effectively out-competes PB mobilized with G-CSF. The enhanced mobilization observed using BOP and AMD3100 is recapitulated in a humanized NODSCIDIL2Rγ−/− model, demonstrated by a significant increase in PB CD34+ cells. Using a related fluorescent analogue of BOP (R-BC154), we show that this class of antagonists preferentially bind human and mouse HSC and progenitors via endogenously primed/activated α9β1/α4β1 within the endosteal niche. These results support using dual α9β1/α4β1 inhibitors as effective, rapid and transient mobilization agents with promising clinical applications. PMID:26975966

  11. Concluding remarks: what's in a name? "Negritos" in the context of the human prehistory of Southeast Asia.

    PubMed

    Ulijaszek, Stanley J

    2013-01-01

    The "negrito" hypothesis posits that various indigenous groups throughout Island and Mainland Southeast Asia have a shared phenotype due to common descent from a putative ancestral population, representing a pre-agricultural substrate of humanity in the region. This has been examined and tested many times in the past, with no clear resolution. With many new resources to hand, the articles in this volume reexamine this hypothesis in a range of different ways. The evidence presented in this double issue of Human Biology speaks more against the category of "negrito" than for it. While populations with the negrito phenotype form a small proportion of all contemporary populations in this region, they have remained a persistent presence. And without a fascination about their origins, there would not be such a depth of knowledge about the human biology of this region more broadly as there is now. Copyright © 2013 Wayne State University Press, Detroit, Michigan 48201-1309.

  12. Long-wave infrared profile feature extractor (PFx) sensor

    NASA Astrophysics Data System (ADS)

    Sartain, Ronald B.; Aliberti, Keith; Alexander, Troy; Chiu, David

    2009-05-01

    The Long Wave Infrared (LWIR) Profile Feature Extractor (PFx) sensor has evolved from the initial profiling sensor that was developed by the University of Memphis (Near IR) and the Army Research Laboratory (visible). This paper presents the initial signatures of the LWIR PFx for human with and without backpacks, human with animal (dog), and a number of other animals. The current version of the LWIR PFx sensor is a diverging optical tripwire sensor. The LWIR PFx signatures are compared to the signatures of the Profile Sensor in the visible and Near IR spectral regions. The LWIR PFx signatures were collected with two different un-cooled micro bolometer focal plane array cameras, where the individual pixels were used as stand alone detectors (a non imaging sensor). This approach results in a completely passive, much lower bandwidth, much longer battery life, low weight, small volume sensor that provides sufficient information to classify objects into human Vs non human categories with a 98.5% accuracy.

  13. The Effect of Naturally Occurring Chronic Kidney Disease on the Micro-Structural and Mechanical Properties of Bone

    PubMed Central

    Meltzer, Hagar; Milrad, Moran; Brenner, Ori; Atkins, Ayelet; Shahar, Ron

    2014-01-01

    Chronic kidney disease (CKD) is a growing public health concern worldwide, and is associated with marked increase of bone fragility. Previous studies assessing the effect of CKD on bone quality were based on biopsies from human patients or on laboratory animal models. Such studies provide information of limited relevance due to the small size of the samples (biopsies) or the non-physiologic CKD syndrome studied (rodent models with artificially induced CKD). Furthermore, the type, architecture, structure and biology of the bone of rodents are remarkably different from human bones; therefore similar clinicopathologic circumstances may affect their bones differently. We describe the effects of naturally occurring CKD with features resembling human CKD on the skeleton of cats, whose bone biology, structure and composition are remarkably similar to those of humans. We show that CKD causes significant increase of resorption cavity density compared with healthy controls, as well as significantly lower cortical mineral density, cortical cross-sectional area and cortical cross-sectional thickness. Young's modulus, yield stress, and ultimate stress of the cortical bone material were all significantly decreased in the skeleton of CKD cats. Cancellous bone was also affected, having significantly lower trabecular thickness and bone volume over total volume in CKD cats compared with controls. This study shows that naturally occurring CKD has deleterious effects on bone quality and strength. Since many similarities exist between human and feline CKD patients, including the clinicopathologic features of the syndrome and bone microarchitecture and biology, these results contribute to better understanding of bone abnormalities associated with CKD. PMID:25333360

  14. SU-E-J-93: Development of Pre-Contoured Human Model Library in DICOM-RT Format for the Epidemiological Study of the Radiotherapy Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pyakuryal, A; Lee, C; Lee, C

    Purpose: Prior to 3D conformal radiation therapy planning, patient anatomy information was mostly limited to 2D beams-eye-view from the conventional simulator. To analyze the outcomes of such treatments for radiation late effects, 3D computational human models are often used in commercial treatment planning systems (TPSs). However, several underlying difficulties such as time-consuming manual delineation procedures of a large number of structures in the model have always limited its applications. Primary objective of this work was to develop a human model library for the epidemiological study by converting 3D-surface model organs to DICOM-RT format (DICOM-RT structure) using an in-house built software.more » We converted the ICRP reference human models to DICOM-RT models, which can be readily adopted for various dose calculations. Methods: MATLAB based code were utilized to convert the contour drawings extracted in text-format from the 3D graphic-tool, Rhinoceros into DICOM-RT structure format for 50 different organs of each model using a 16GB dual-core processor. The conversion periods were measured for each DICOM-RT models, and the reconstructed structure volumes were validated against the original 3D-surface models in the TPS. Ten reference hybrid whole-body models (8-pediatric and 2-adults) were automatically processed to create DICOM-RT computational human model library. Results: Mean contour conversion period was found to be 580 (N=2) and 394.5 (N=8) seconds for 50 organs in the adult and pediatric models respectively. A good agreement for large organs (NRMSD <1.0%) and small organs (NRMSD <7.7%) was also observed between the original volumes and corresponding DICOM-RT structure volumes of the organs. Conclusion: The ICRP reference human models were converted into DICOM-RT format to support the epidemiological study using a large cohort of conventional radiotherapy patients. Due to its DICOM-compatibility, the library may be implemented to many other different applications. We also expect to develop the library by including additional models in future.« less

  15. A new method for depth profiling reconstruction in confocal microscopy

    NASA Astrophysics Data System (ADS)

    Esposito, Rosario; Scherillo, Giuseppe; Mensitieri, Giuseppe

    2018-05-01

    Confocal microscopy is commonly used to reconstruct depth profiles of chemical species in multicomponent systems and to image nuclear and cellular details in human tissues via image intensity measurements of optical sections. However, the performance of this technique is reduced by inherent effects related to wave diffraction phenomena, refractive index mismatch and finite beam spot size. All these effects distort the optical wave and cause an image to be captured of a small volume around the desired illuminated focal point within the specimen rather than an image of the focal point itself. The size of this small volume increases with depth, thus causing a further loss of resolution and distortion of the profile. Recently, we proposed a theoretical model that accounts for the above wave distortion and allows for a correct reconstruction of the depth profiles for homogeneous samples. In this paper, this theoretical approach has been adapted for describing the profiles measured from non-homogeneous distributions of emitters inside the investigated samples. The intensity image is built by summing the intensities collected from each of the emitters planes belonging to the illuminated volume, weighed by the emitters concentration. The true distribution of the emitters concentration is recovered by a new approach that implements this theoretical model in a numerical algorithm based on the Maximum Entropy Method. Comparisons with experimental data and numerical simulations show that this new approach is able to recover the real unknown concentration distribution from experimental profiles with an accuracy better than 3%.

  16. NASA-STD 3001 and the Human Integration Design Handbook (HIDH): Evolution of NASA-STD-3000

    NASA Technical Reports Server (NTRS)

    Pickett, Lynn; Connolly, Janis; Arch, M.; Tillman, Barry; Russo, Dane

    2007-01-01

    The Habitability & Environmental Factors and Space Medicine Divisions have developed the Space Flight Human System Standard (SFHSS) (NASA-STD-3001) to replace NASA-STD-3000 as a new NASA standard for all human spaceflight programs. The SFHSS is composed of 2 volumes. Volume 1, Crew Health, contains medical levels of care, permissible exposure limits, and fitness for duty criteria, and permissible outcome limits as a means of defining successful operating criteria for the human system. Volume 2, Habitability and Environmental Health, contains environmental, habitability and human factors standards. Development of the Human Integration Design Handbook (HIDH), a companion to the standard, is currently under construction and entails the update and revision of NASA-STD-3000 data. This new handbook will, in the fashion of NASA STD-3000, assist engineers and designers in appropriately applying habitability, environmental and human factors principles to spacecraft design. Organized in a chapter-module-element structure, the HIDH will provide the guidance for the development of requirements, design considerations, lessons learned, example solutions, background research, and assist in the identification of gaps and research needs in the disciplines. Subject matter experts have been and continue to be solicited to participate in the update of the chapters. The purpose is to build the HIDH with the best and latest data, and provide a broad representation from experts in industry, academia, the military and the space program. The handbook and the two standards volumes work together in a unique way to achieve the required level of human-system interface. All new NASA programs will be required to meet Volumes 1 and 2. Volume 2 presents human interface goals in broad, non-verifiable standards. Volume 2 also requires that each new development program prepare a set of program-specific human factors requirements. These program-specific human and environmental factors requirements must be verifiable and tailored to assure the new system meets the Volume 2 standards. Programs will use the HIDH to write their verifiable program-specific requirements.

  17. Influence of carbon nanoparticle modification on the mechanical and electrical properties of epoxy in small volumes.

    PubMed

    Leopold, Christian; Augustin, Till; Schwebler, Thomas; Lehmann, Jonas; Liebig, Wilfried V; Fiedler, Bodo

    2017-11-15

    The influence of nanoparticle morphology and filler content on the mechanical and electrical properties of carbon nanoparticle modified epoxy is investigated regarding small volumes. Three types of particles, representing spherical, tubular and layered morphologies are used. A clear size effect of increasing true failure strength with decreasing volume is found for neat and carbon black modified epoxy. Carbon nanotube (CNT) modified epoxy exhibits high potential for strength increase, but dispersion and purity are critical. In few layer graphene modified epoxy, particles are larger than statistically distributed defects and initiate cracks, counteracting any size effect. Different toughness increasing mechanisms on the nano- and micro-scale depending on particle morphology are discussed based on scanning electron microscopy images. Electrical percolation thresholds in the small volume fibres are significantly higher compared to bulk volume, with CNT being found to be the most suitable morphology to form electrical conductive paths. Good correlation between electrical resistance change and stress strain behaviour under tensile loads is observed. The results show the possibility to detect internal damage in small volumes by measuring electrical resistance and therefore indicate to the high potential for using CNT modified polymers in fibre reinforced plastics as a multifunctional, self-monitoring material with improved mechanical properties. Copyright © 2017. Published by Elsevier Inc.

  18. Small-volume amnioinfusion: a potential stimulus of intrapartum fetal heart rate accelerations.

    PubMed

    Wax, Joseph R; Flaherty, Nina; Pinette, Michael G; Blackstone, Jacquelyn; Cartin, Angelina

    2004-02-01

    We describe a recurrent nonreassuring fetal heart rate pattern in which small-volume amnioinfusions apparently evoked fetal heart rate accelerations suggested fetal well-being, allowing that progressive labor that culminated in the vaginal delivery of a healthy infant.

  19. Small-Volume Injections: Evaluation of Volume Administration Deviation From Intended Injection Volumes.

    PubMed

    Muffly, Matthew K; Chen, Michael I; Claure, Rebecca E; Drover, David R; Efron, Bradley; Fitch, William L; Hammer, Gregory B

    2017-10-01

    In the perioperative period, anesthesiologists and postanesthesia care unit (PACU) nurses routinely prepare and administer small-volume IV injections, yet the accuracy of delivered medication volumes in this setting has not been described. In this ex vivo study, we sought to characterize the degree to which small-volume injections (≤0.5 mL) deviated from the intended injection volumes among a group of pediatric anesthesiologists and pediatric postanesthesia care unit (PACU) nurses. We hypothesized that as the intended injection volumes decreased, the deviation from those intended injection volumes would increase. Ten attending pediatric anesthesiologists and 10 pediatric PACU nurses each performed a series of 10 injections into a simulated patient IV setup. Practitioners used separate 1-mL tuberculin syringes with removable 18-gauge needles (Becton-Dickinson & Company, Franklin Lakes, NJ) to aspirate 5 different volumes (0.025, 0.05, 0.1, 0.25, and 0.5 mL) of 0.25 mM Lucifer Yellow (LY) fluorescent dye constituted in saline (Sigma Aldrich, St. Louis, MO) from a rubber-stoppered vial. Each participant then injected the specified volume of LY fluorescent dye via a 3-way stopcock into IV tubing with free-flowing 0.9% sodium chloride (10 mL/min). The injected volume of LY fluorescent dye and 0.9% sodium chloride then drained into a collection vial for laboratory analysis. Microplate fluorescence wavelength detection (Infinite M1000; Tecan, Mannedorf, Switzerland) was used to measure the fluorescence of the collected fluid. Administered injection volumes were calculated based on the fluorescence of the collected fluid using a calibration curve of known LY volumes and associated fluorescence.To determine whether deviation of the administered volumes from the intended injection volumes increased at lower injection volumes, we compared the proportional injection volume error (loge [administered volume/intended volume]) for each of the 5 injection volumes using a linear regression model. Analysis of variance was used to determine whether the absolute log proportional error differed by the intended injection volume. Interindividual and intraindividual deviation from the intended injection volume was also characterized. As the intended injection volumes decreased, the absolute log proportional injection volume error increased (analysis of variance, P < .0018). The exploratory analysis revealed no significant difference in the standard deviations of the log proportional errors for injection volumes between physicians and pediatric PACU nurses; however, the difference in absolute bias was significantly higher for nurses with a 2-sided significance of P = .03. Clinically significant dose variation occurs when injecting volumes ≤0.5 mL. Administering small volumes of medications may result in unintended medication administration errors.

  20. Genetic variations in the serotonergic system contribute to amygdala volume in humans.

    PubMed

    Li, Jin; Chen, Chunhui; Wu, Karen; Zhang, Mingxia; Zhu, Bi; Chen, Chuansheng; Moyzis, Robert K; Dong, Qi

    2015-01-01

    The amygdala plays a critical role in emotion processing and psychiatric disorders associated with emotion dysfunction. Accumulating evidence suggests that amygdala structure is modulated by serotonin-related genes. However, there is a gap between the small contributions of single loci (less than 1%) and the reported 63-65% heritability of amygdala structure. To understand the "missing heritability," we systematically explored the contribution of serotonin genes on amygdala structure at the gene set level. The present study of 417 healthy Chinese volunteers examined 129 representative polymorphisms in genes from multiple biological mechanisms in the regulation of serotonin neurotransmission. A system-level approach using multiple regression analyses identified that nine SNPs collectively accounted for approximately 8% of the variance in amygdala volume. Permutation analyses showed that the probability of obtaining these findings by chance was low (p = 0.043, permuted for 1000 times). Findings showed that serotonin genes contribute moderately to individual differences in amygdala volume in a healthy Chinese sample. These results indicate that the system-level approach can help us to understand the genetic basis of a complex trait such as amygdala structure.

  1. Practical methods for generating alternating magnetic fields for biomedical research

    NASA Astrophysics Data System (ADS)

    Christiansen, Michael G.; Howe, Christina M.; Bono, David C.; Perreault, David J.; Anikeeva, Polina

    2017-08-01

    Alternating magnetic fields (AMFs) cause magnetic nanoparticles (MNPs) to dissipate heat while leaving surrounding tissue unharmed, a mechanism that serves as the basis for a variety of emerging biomedical technologies. Unfortunately, the challenges and costs of developing experimental setups commonly used to produce AMFs with suitable field amplitudes and frequencies present a barrier to researchers. This paper first presents a simple, cost-effective, and robust alternative for small AMF working volumes that uses soft ferromagnetic cores to focus the flux into a gap. As the experimental length scale increases to accommodate animal models (working volumes of 100s of cm3 or greater), poor thermal conductivity and volumetrically scaled core losses render that strategy ineffective. Comparatively feasible strategies for these larger volumes instead use low loss resonant tank circuits to generate circulating currents of 1 kA or greater in order to produce the comparable field amplitudes. These principles can be extended to the problem of identifying practical routes for scaling AMF setups to humans, an infrequently acknowledged challenge that influences the extent to which many applications of MNPs may ever become clinically relevant.

  2. Community biomass handbook volume 4: enterprise development for integrated wood manufacturing

    Treesearch

    Eini Lowell; D.R. Becker; D. Smith; M. Kauffman; D. Bihn

    2017-01-01

    The Community Biomass Handbook Volume 4: Enterprise Development for Integrated Wood Manufacturing is a guide for creating sustainable business enterprises using small diameter logs and biomass. This fourth volume is a companion to three Community Biomass Handbook volumes: Volume 1: Thermal Wood Energy; Volume 2: Alaska, Where Woody Biomass Can Work; and Volume 3: How...

  3. Construction of a Liposome Dialyzer for preparation of high-value, small-volume liposome formulations

    PubMed Central

    Adamala, Katarzyna; Engelhart, Aaron E.; Kamat, Neha P.; Jin, Lin; Szostak, Jack W.

    2016-01-01

    The liposome dialyzer is a small-volume equilibrium dialysis device, built from commercially available materials, that is designed for rapid exchange of small volumes of an extraliposomal reagent pool against a liposome preparation. The dialyzer is prepared by modification of commercially available dialysis cartridges and consists of a reactor with two 300 µL chambers and a 1.56 cm2 dialysis surface area. The dialyzer is prepared in three stages: 1) disassembly of dialysis cartridges to obtain required parts; 2) assembly of the dialyzer; and 3) sealing the dialyzer with epoxy. Preparation of the dialyser takes about 1.5 h, not including overnight epoxy curing. Each round of dialysis takes 1–24 h, depending on the analyte and membrane employed. We previously used the dialyzer for small-volume nonenzymatic RNA synthesis reactions inside fatty acid vesicles. In this protocol, we demonstrate other applications, including removal of unencapsulated calcein from vesicles, remote loading, and vesicle microscopy. PMID:26020615

  4. Construction of a liposome dialyzer for the preparation of high-value, small-volume liposome formulations.

    PubMed

    Adamala, Katarzyna; Engelhart, Aaron E; Kamat, Neha P; Jin, Lin; Szostak, Jack W

    2015-06-01

    The liposome dialyzer is a small-volume equilibrium dialysis device, built from commercially available materials, that is designed for the rapid exchange of small volumes of an extraliposomal reagent pool against a liposome preparation. The dialyzer is prepared by modification of commercially available dialysis cartridges (Slide-A-Lyzer cassettes), and it consists of a reactor with two 300-μl chambers and a 1.56-cm(2) dialysis surface area. The dialyzer is prepared in three stages: (i) disassembling the dialysis cartridges to obtain the required parts, (ii) assembling the dialyzer and (iii) sealing the dialyzer with epoxy. Preparation of the dialyzer takes ∼1.5 h, not including overnight epoxy curing. Each round of dialysis takes 1-24 h, depending on the analyte and membrane used. We previously used the dialyzer for small-volume non-enzymatic RNA synthesis reactions inside fatty acid vesicles. In this protocol, we demonstrate other applications, including removal of unencapsulated calcein from vesicles, remote loading and vesicle microscopy.

  5. A radiographic method to estimate lung volume and its use in small mammals.

    PubMed

    Canals, Mauricio; Olivares, Ricardo; Rosenmann, Mario

    2005-01-01

    In this paper we develop a method to estimate lung volume using chest x-rays of small mammals. We applied this method to assess the lung volume of several rodents. We showed that a good estimator of the lung volume is: V*L = 0.496 x VRX approximately equal to 1/2 x VRX, where VRX is a measurement obtained from the x-ray that represents the volume of a rectangular box containing the lungs and mediastinum organs. The proposed formula may be interpreted as the volume of an ellipsoid formed by both lungs joined at their bases. When that relationship was used to estimate lung volume, values similar to those expected from allometric relationship were found in four rodents. In two others, M. musculus and R. norvegicus, lung volume was similar to reported data, although values were lower than expected.

  6. Dietary quality and encephalization in platyrrhine primates.

    PubMed

    Allen, Kari L; Kay, Richard F

    2012-02-22

    The high energetic costs of building and maintaining large brains are thought to constrain encephalization. The 'expensive-tissue hypothesis' (ETH) proposes that primates (especially humans) overcame this constraint through reduction of another metabolically expensive tissue, the gastrointestinal tract. Small guts characterize animals specializing on easily digestible diets. Thus, the hypothesis may be tested via the relationship between brain size and diet quality. Platyrrhine primates present an interesting test case, as they are more variably encephalized than other extant primate clades (excluding Hominoidea). We find a high degree of phylogenetic signal in the data for diet quality, endocranial volume and body size. Controlling for phylogenetic effects, we find no significant correlation between relative diet quality and relative endocranial volume. Thus, diet quality fails to account for differences in platyrrhine encephalization. One taxon, in particular, Brachyteles, violates predictions made by ETH in having a large brain and low-quality diet. Dietary reconstructions of stem platyrrhines further indicate that a relatively high-quality diet was probably in place prior to increases in encephalization. Therefore, it is unlikely that a shift in diet quality was a primary constraint release for encephalization in platyrrhines and, by extrapolation, humans.

  7. Multiplying Mars Lander Opportunities with Marsdrop Microlanders

    NASA Technical Reports Server (NTRS)

    Staehle, Robert L.; Spangelo, Sara; Lane, Marc S.; Aaron, Kim M.; Bhartia, Rohit; Boland, Justin S.; Christensen, Lance E.; Forouhar, Siamak; de la Torre Juarez, Manuel; Trawny, Nikolas; hide

    2015-01-01

    From canyons to glaciers, from geology to astrobiology, the amount of exciting surface science awaiting us at Mars greatly outstrips available mission opportunities. Based on the thrice -flown Aerospace Corporation Earth Reentry Breakup Recorder (REBR), we present a method for accurate landing of small instrument payloads on Mars, utilizing excess cruise -stage mass on larger missions. One to a few such microlanders might add 1-5% to the cost of a primary mission with inconsequential risk. Using the REBR and JPL Deep Space 2 starting points for a passively stable entry vehicle provides a low mass and low ballistic coefficient, enabling subsonic d employment of a steerable parawing glider, capable of 10+ km of guided flight at a 3:1 glide ratio. Originally developed for the Gemini human space program, the parawing is attractive for a volume -limited microprobe, minimizing descent velocity, and providing sufficient remaining volume for a useful scientific payload. The ability to steer the parawing during descent opens unique opportunities, including terrain- relative navigation for landing within tens of meters of one of several specified targets within a given uncertainty ellipse. In addition to scientific value, some Mars human exploration Strategic Knowledge Gaps could be addressed with deployment of focused instruments at multiple locations.

  8. Amperometric micro pH measurements in oxygenated saliva.

    PubMed

    Chaisiwamongkhol, Korbua; Batchelor-McAuley, Christopher; Compton, Richard G

    2017-07-24

    An amperometric micro pH sensor has been developed based on the chemical oxidation of carbon fibre surfaces (diameter of 9 μm and length of ca. 1 mm) to enhance the population of surface quinone groups for the measurement of salivary pH. The pH analysis utilises the electrochemically reversible two-electron, two-proton behaviour of surface quinone groups on the micro-wire electrodes. A Nernstian response is observed across the pH range 2-8 which is the pH range of many biological fluids. We highlight the measurement of pH in small volumes of biological fluids without the need for oxygen removal and specifically the micro pH electrode is examined by measuring the pH of commercial synthetic saliva and authentic human saliva samples. The results correspond well with those obtained by using commercial glass pH electrodes on large volume samples.

  9. Arbitrary Inequality in Reputation Systems

    NASA Astrophysics Data System (ADS)

    Frey, Vincenz; van de Rijt, Arnout

    2016-12-01

    Trust is an essential condition for exchange. Large societies must substitute the trust traditionally provided through kinship and sanctions in small groups to make exchange possible. The rise of internet-supported reputation systems has been celebrated for providing trust at a global scale, enabling the massive volumes of transactions between distant strangers that are characteristic of modern human societies. Here we problematize an overlooked side-effect of reputation systems: Equally trustworthy individuals may realize highly unequal exchange volumes. We report the results of a laboratory experiment that shows emergent differentiation between ex ante equivalent individuals when information on performance in past exchanges is shared. This arbitrary inequality results from cumulative advantage in the reputation-building process: Random initial distinctions grow as parties of good repute are chosen over those lacking a reputation. We conjecture that reputation systems produce artificial concentration in a wide range of markets and leave superior but untried exchange alternatives unexploited.

  10. Arbitrary Inequality in Reputation Systems

    PubMed Central

    Frey, Vincenz; van de Rijt, Arnout

    2016-01-01

    Trust is an essential condition for exchange. Large societies must substitute the trust traditionally provided through kinship and sanctions in small groups to make exchange possible. The rise of internet-supported reputation systems has been celebrated for providing trust at a global scale, enabling the massive volumes of transactions between distant strangers that are characteristic of modern human societies. Here we problematize an overlooked side-effect of reputation systems: Equally trustworthy individuals may realize highly unequal exchange volumes. We report the results of a laboratory experiment that shows emergent differentiation between ex ante equivalent individuals when information on performance in past exchanges is shared. This arbitrary inequality results from cumulative advantage in the reputation-building process: Random initial distinctions grow as parties of good repute are chosen over those lacking a reputation. We conjecture that reputation systems produce artificial concentration in a wide range of markets and leave superior but untried exchange alternatives unexploited. PMID:27995957

  11. Homo naledi, a new species of the genus Homo from the Dinaledi Chamber, South Africa

    PubMed Central

    Berger, Lee R; Hawks, John; de Ruiter, Darryl J; Churchill, Steven E; Schmid, Peter; Delezene, Lucas K; Kivell, Tracy L; Garvin, Heather M; Williams, Scott A; DeSilva, Jeremy M; Skinner, Matthew M; Musiba, Charles M; Cameron, Noel; Holliday, Trenton W; Harcourt-Smith, William; Ackermann, Rebecca R; Bastir, Markus; Bogin, Barry; Bolter, Debra; Brophy, Juliet; Cofran, Zachary D; Congdon, Kimberly A; Deane, Andrew S; Dembo, Mana; Drapeau, Michelle; Elliott, Marina C; Feuerriegel, Elen M; Garcia-Martinez, Daniel; Green, David J; Gurtov, Alia; Irish, Joel D; Kruger, Ashley; Laird, Myra F; Marchi, Damiano; Meyer, Marc R; Nalla, Shahed; Negash, Enquye W; Orr, Caley M; Radovcic, Davorka; Schroeder, Lauren; Scott, Jill E; Throckmorton, Zachary; Tocheri, Matthew W; VanSickle, Caroline; Walker, Christopher S; Wei, Pianpian; Zipfel, Bernhard

    2015-01-01

    Homo naledi is a previously-unknown species of extinct hominin discovered within the Dinaledi Chamber of the Rising Star cave system, Cradle of Humankind, South Africa. This species is characterized by body mass and stature similar to small-bodied human populations but a small endocranial volume similar to australopiths. Cranial morphology of H. naledi is unique, but most similar to early Homo species including Homo erectus, Homo habilis or Homo rudolfensis. While primitive, the dentition is generally small and simple in occlusal morphology. H. naledi has humanlike manipulatory adaptations of the hand and wrist. It also exhibits a humanlike foot and lower limb. These humanlike aspects are contrasted in the postcrania with a more primitive or australopith-like trunk, shoulder, pelvis and proximal femur. Representing at least 15 individuals with most skeletal elements repeated multiple times, this is the largest assemblage of a single species of hominins yet discovered in Africa. DOI: http://dx.doi.org/10.7554/eLife.09560.001 PMID:26354291

  12. Big data from small data: data-sharing in the ‘long tail’ of neuroscience

    PubMed Central

    Ferguson, Adam R; Nielson, Jessica L; Cragin, Melissa H; Bandrowski, Anita E; Martone, Maryann E

    2016-01-01

    The launch of the US BRAIN and European Human Brain Projects coincides with growing international efforts toward transparency and increased access to publicly funded research in the neurosciences. The need for data-sharing standards and neuroinformatics infrastructure is more pressing than ever. However, ‘big science’ efforts are not the only drivers of data-sharing needs, as neuroscientists across the full spectrum of research grapple with the overwhelming volume of data being generated daily and a scientific environment that is increasingly focused on collaboration. In this commentary, we consider the issue of sharing of the richly diverse and heterogeneous small data sets produced by individual neuroscientists, so-called long-tail data. We consider the utility of these data, the diversity of repositories and options available for sharing such data, and emerging best practices. We provide use cases in which aggregating and mining diverse long-tail data convert numerous small data sources into big data for improved knowledge about neuroscience-related disorders. PMID:25349910

  13. Volume measurements on three-dimensional photogrammetry after extended strip versus total cranial remodeling for sagittal synostosis: A comparative cohort study.

    PubMed

    van Veelen, Marie-Lise C; Jippes, Marielle; Carolina, Julius-Carl A; de Rooi, Johan; Dirven, Clemens M F; van Adrichem, Leon N A; Mathijssen, Irene M

    2016-10-01

    Surgery for sagittal synostosis aims at correction of skull shape and restoration of growth potential. Small cranial volume is associated with raised intracranial pressure (ICP). Although many techniques have been described, information on postoperative volume related to early and late remodeling is lacking. Between 2004 and 2008, a total of 95 patients were collected who underwent either early extended strip craniectomy or late total cranial remodeling according to age of presentation. Volume was measured on three-dimensional (3D) photogrammetry. Volume measurements were related to cranial index (CI), head circumference (HCsd), and signs of raised ICP. In a small subset of patients, volume measurements on 3D photogrammetry were assessed for inter- and intrarater reliability and compared to 3D computed tomography (CT). Volume was increased in all patients before and after surgery compared to normative values. Postoperatively, late total cranial remodeling resulted in a slightly larger volume than early extended strip craniectomy. Volume measurements showed a good correlation with HCsd (0.67) and a poor relationship with CI (0.13). Headache occurred more frequently in patients with a lower cranial volume. Although papilledema and reoperation showed the same trend, the numbers were too small for statistical analysis. Reproducibility of volume measurements on 3D photogrammetry was high, as was the correlation with measurements on CT. Late total cranial remodeling results in a larger postoperative volume, as measured on 3D photogrammetry, than extended strip craniectomy. Clinical signs of raised ICP occur more frequently in patients with a smaller volume. To measure volume, 3D photogrammetry is a good alternative to CT. Copyright © 2016. Published by Elsevier Ltd.

  14. Dependence of the clustering properties of galaxies on stellar velocity dispersion in the Main galaxy sample of SDSS DR10

    NASA Astrophysics Data System (ADS)

    Deng, Xin-Fa; Song, Jun; Chen, Yi-Qing; Jiang, Peng; Ding, Ying-Ping

    2014-08-01

    Using two volume-limited Main galaxy samples of the Sloan Digital Sky Survey Data Release 10 (SDSS DR10), we investigate the dependence of the clustering properties of galaxies on stellar velocity dispersion by cluster analysis. It is found that in the luminous volume-limited Main galaxy sample, except at r=1.2, richer and larger systems can be more easily formed in the large stellar velocity dispersion subsample, while in the faint volume-limited Main galaxy sample, at r≥0.9, an opposite trend is observed. According to statistical analyses of the multiplicity functions, we conclude in two volume-limited Main galaxy samples: small stellar velocity dispersion galaxies preferentially form isolated galaxies, close pairs and small group, while large stellar velocity dispersion galaxies preferentially inhabit the dense groups and clusters. However, we note the difference between two volume-limited Main galaxy samples: in the faint volume-limited Main galaxy sample, at r≥0.9, the small stellar velocity dispersion subsample has a higher proportion of galaxies in superclusters ( n≥200) than the large stellar velocity dispersion subsample.

  15. In vitro platelet quality in storage containers used for pediatric transfusions.

    PubMed

    Weiss, Sandra; Scammell, Kenneth; Levin, Elena; Culibrk, Brankica; Zolfaghari, Sima; Gyöngyössy-Issa, Maria I C; Acker, Jason P

    2012-08-01

    The in vitro quality of small-volume platelet (PLT) aliquots for pediatric transfusions was assessed to determine the best practice approach. Small volumes (50 mL) of single apheresis PLT components (APCs), collected on either CaridianBCT Trima or Haemonetics MCS+ instruments, were aliquoted on Days 2, 3, 4, and 5 postcollection into Fenwal PL1240 or 4R2014 bags or 60-mL polypropylene syringes. Samples were tested for in vitro quality at their recommended expiry times (4 hr for 4R2014 bags and syringes or Day 5 for PL1240 bags). Assays included pH, CD62P expression, and metabolic measures. CD62P expression increased throughout storage in all containers. Among the small-volume containers, pH, pCO(2) , lactate, and bicarbonate varied considerably. Regardless of the day of aliquoting, pCO(2) was significantly higher and pO(2) was significantly lower in gas-impermeable syringes than other containers. No bacterial growth was detected in any sample. The quality of APCs aliquoted into small-volume containers meets regulatory requirements and is generally equivalent to that of full-volume APCs at expiry. © 2012 American Association of Blood Banks.

  16. 3-D ultrafast Doppler imaging applied to the noninvasive mapping of blood vessels in vivo.

    PubMed

    Provost, Jean; Papadacci, Clement; Demene, Charlie; Gennisson, Jean-Luc; Tanter, Mickael; Pernot, Mathieu

    2015-08-01

    Ultrafast Doppler imaging was introduced as a technique to quantify blood flow in an entire 2-D field of view, expanding the field of application of ultrasound imaging to the highly sensitive anatomical and functional mapping of blood vessels. We have recently developed 3-D ultrafast ultrasound imaging, a technique that can produce thousands of ultrasound volumes per second, based on a 3-D plane and diverging wave emissions, and demonstrated its clinical feasibility in human subjects in vivo. In this study, we show that noninvasive 3-D ultrafast power Doppler, pulsed Doppler, and color Doppler imaging can be used to perform imaging of blood vessels in humans when using coherent compounding of 3-D tilted plane waves. A customized, programmable, 1024-channel ultrasound system was designed to perform 3-D ultrafast imaging. Using a 32 × 32, 3-MHz matrix phased array (Vermon, Tours, France), volumes were beamformed by coherently compounding successive tilted plane wave emissions. Doppler processing was then applied in a voxel-wise fashion. The proof of principle of 3-D ultrafast power Doppler imaging was first performed by imaging Tygon tubes of various diameters, and in vivo feasibility was demonstrated by imaging small vessels in the human thyroid. Simultaneous 3-D color and pulsed Doppler imaging using compounded emissions were also applied in the carotid artery and the jugular vein in one healthy volunteer.

  17. 3-D Ultrafast Doppler Imaging Applied to the Noninvasive and Quantitative Imaging of Blood Vessels in Vivo

    PubMed Central

    Provost, J.; Papadacci, C.; Demene, C.; Gennisson, J-L.; Tanter, M.; Pernot, M.

    2016-01-01

    Ultrafast Doppler Imaging was introduced as a technique to quantify blood flow in an entire 2-D field of view, expanding the field of application of ultrasound imaging to the highly sensitive anatomical and functional mapping of blood vessels. We have recently developed 3-D Ultrafast Ultrasound Imaging, a technique that can produce thousands of ultrasound volumes per second, based on three-dimensional plane and diverging wave emissions, and demonstrated its clinical feasibility in human subjects in vivo. In this study, we show that non-invasive 3-D Ultrafast Power Doppler, Pulsed Doppler, and Color Doppler Imaging can be used to perform quantitative imaging of blood vessels in humans when using coherent compounding of three-dimensional tilted plane waves. A customized, programmable, 1024-channel ultrasound system was designed to perform 3-D Ultrafast Imaging. Using a 32X32, 3-MHz matrix phased array (Vermon, France), volumes were beamformed by coherently compounding successive tilted plane wave emissions. Doppler processing was then applied in a voxel-wise fashion. 3-D Ultrafast Power Doppler Imaging was first validated by imaging Tygon tubes of varying diameter and its in vivo feasibility was demonstrated by imaging small vessels in the human thyroid. Simultaneous 3-D Color and Pulsed Doppler Imaging using compounded emissions were also applied in the carotid artery and the jugular vein in one healthy volunteer. PMID:26276956

  18. The Consequences of Metric Production for Small Manufacturers. Volume II. Case Studies of Large Business-Small Business Interaction,

    DTIC Science & Technology

    1982-02-08

    II 00 CASE STUDIES OF LARGE BUSINESS - SMALL BUSINESS INTERACTION ’C- DTIC. Henry H1. Hitchcock dlELECTE7 Joseph F. Coates Marcy M. Canavan AUGG261982...J wis&omWWS1ARET N W WASIINGTOW. OC NO$I THE CONSEQUENCES OF METRIC PRODUCTION FOR SMALL MANUFACTURERS Volume 11 CASE STUDIES OF LARGE BUSINESS ... SMALL BUSINESS INTERACTION Accesqi~r, For NTIS GRA&t DTIC TAB Unannoun~ced J’htiI’ctof _ Henry H. Hitchcock vi 1ribr i t o aes Joseph F. Coates Avail arid

  19. Spontaneous representations of small numbers of objects by rhesus macaques: examinations of content and format.

    PubMed

    Hauser, Marc D; Carey, Susan

    2003-12-01

    The project of comparative cognition benefits from common measures across species. We report here on five experiments using the violation of expectancy looking time measure with free-ranging rhesus macaques (Macaca mulatta), each designed to build on current knowledge concerning spontaneous representations of number. Each subject, tested in only one experimental condition, watched as eggplants were placed behind a screen one at a time, after which the screen was removed revealing an outcome that either matched or did not match the number placed there. Subjects looked longer at impossible than possible outcomes in 1+1=2 or 3, 1 small+1 small=1 big or 2 small, 2+1=2 or 3, and 2+1=3 or 4 conditions. They failed in 2+1+1=4 or 3 or 5 and in 1+1+1=2 or 3 conditions. This pattern of results closely matches that observed across several previous studies of human infants. The data allow us to test among four different proposals concerning the format and content of the mental representations underlying looking in these experiments. Object file representations are favored over: (i) low-level perceptual representations, (ii) representations of continuous variables such as volume or surface area, and (iii) analog magnitude representations of number. We conclude by considering exactly how the object tracking system revealed in these and other related experiments does and does not represent number, and how it might be one evolutionary precursor of the human specific system of number representations.

  20. Measurement of complex joint trajectories using slice-to-volume 2D/3D registration and cine MR

    NASA Astrophysics Data System (ADS)

    Bloch, C.; Figl, M.; Gendrin, C.; Weber, C.; Unger, E.; Aldrian, S.; Birkfellner, W.

    2010-02-01

    A method for studying the in vivo kinematics of complex joints is presented. It is based on automatic fusion of single slice cine MR images capturing the dynamics and a static MR volume. With the joint at rest the 3D scan is taken. In the data the anatomical compartments are identified and segmented resulting in a 3D volume of each individual part. In each of the cine MR images the joint parts are segmented and their pose and position are derived using a 2D/3D slice-to-volume registration to the volumes. The method is tested on the carpal joint because of its complexity and the small but complex motion of its compartments. For a first study a human cadaver hand was scanned and the method was evaluated with artificially generated slice images. Starting from random initial positions of about 5 mm translational and 12° rotational deviation, 70 to 90 % of the registrations converged successfully to a deviation better than 0.5 mm and 5°. First evaluations using real data from a cine MR were promising. The feasibility of the method was demonstrated. However we experienced difficulties with the segmentation of the cine MR images. We therefore plan to examine different parameters for the image acquisition in future studies.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Medin, Paul M., E-mail: Paul.medin@utsouthwestern.ed; Boike, Thomas P.

    Clinical implementation of spinal radiosurgery has increased rapidly in recent years, but little is known regarding human spinal cord tolerance to single-fraction irradiation. In contrast, preclinical studies in single-fraction spinal cord tolerance have been ongoing since the 1970s. The influences of field length, dose rate, inhomogeneous dose distributions, and reirradiation have all been investigated. This review summarizes literature regarding single-fraction spinal cord tolerance in preclinical models with an emphasis on practical clinical significance. The outcomes of studies that incorporate uniform irradiation are surprisingly consistent among multiple small- and large-animal models. Extensive investigation of inhomogeneous dose distributions in the rat hasmore » demonstrated a significant dose-volume effect while preliminary results from one pig study are contradictory. Preclinical spinal cord dose-volume studies indicate that dose distribution is more critical than the volume irradiated suggesting that neither dose-volume histogram analysis nor absolute volume constraints are effective in predicting complications. Reirradiation data are sparse, but results from guinea pig, rat, and pig studies are consistent with the hypothesis that the spinal cord possesses a large capacity for repair. The mechanisms behind the phenomena observed in spinal cord studies are not readily explained and the ability of dose response models to predict outcomes is variable underscoring the need for further investigation. Animal studies provide insight into the phenomena and mechanisms of radiosensitivity but the true significance of animal studies can only be discovered through clinical trials.« less

  2. The Retriever, Volume 2, Nos. 1 & 2, 1967. ERIC Clearinghouse on Rural Education and Small Schools (CRESS) Newsletter.

    ERIC Educational Resources Information Center

    ERIC Clearinghouse on Rural Education and Small Schools, Las Cruces, NM.

    Volume 2, Numbers 1 and 2 of the ERIC/CRESS (Educational Research Information Center/Clearinghouse on Rural education and Small Schools) newsletter focus on the status of CRESS and innovations in the small rural school. Issue Number 1 discusses the status of the Clearinghouse at the end of 3 months into the second year of operation. A 14-item…

  3. COLLECTION EFFICIENCY OF THE HIGH VOLUME SMALL SURFACE SAMPLER ON WORN CARPETS

    EPA Science Inventory

    Collection Efficiency of the High Volume Small Surface Sampler on Worn Carpets

    Erik R. Svendsen*?, Peter S. Thorne*, Stephen J. Reynolds*?, Patrick T. O'Shaughnessy*, Alba Quinones*, Dale Zimmerman*, and Nervana Metwali*

    *University of Iowa College of Public Health<...

  4. Black Cherry Volume Tables for Furniture-Type, Flat, 4/4-Inch Dimension from Small Low-Quality Trees.

    Treesearch

    Eugene F. Landt

    1974-01-01

    Volume tables are given for yield of clear-one-side, flat dimension from small, low-quality trees and boldts removed in a stand improvement cut of 54- to 76-year-old black cherry trees from northern Pennsylvania.

  5. Soft Maple Volume Tables for Furniture-Type, Flat, 4/4-Inch Dimension from Small Low-Quality Trees

    Treesearch

    Eugene F. Landt

    1974-01-01

    Volume tables are given for yield of clear-one-side, flat dimension from small low-quality trees and bolts removed in a stand improvemtn cut of 18- to 44-year-old soft maple trees in southern Illinois.

  6. Automation of Command and Data Entry in a Glovebox Work Volume: An Evaluation of Data Entry Devices

    NASA Technical Reports Server (NTRS)

    Steele, Marianne K.; Nakamura, Gail; Havens, Cindy; LeMay, Moira

    1996-01-01

    The present study was designed to examine the human-computer interface for data entry while performing experimental procedures within a glovebox work volume in order to make a recommendation to the Space Station Biological Research Project for a data entry system to be used within the Life Sciences Glovebox. Test subjects entered data using either a manual keypad, similar to a standard computer numerical keypad located within the glovebox work volume, or a voice input system using a speech recognition program with a microphone headset. Numerical input and commands were programmed in an identical manner between the two systems. With both electronic systems, a small trackball was available within the work volume for cursor control. Data, such as sample vial identification numbers, sample tissue weights, and health check parameters of the specimen, were entered directly into procedures that were electronically displayed on a video monitor within the glovebox. A pen and paper system with a 'flip-chart' format for procedure display, similar to that currently in use on the Space Shuttle, was used as a baseline data entry condition. Procedures were performed by a single operator; eight test subjects were used in the study. The electronic systems were tested under both a 'nominal' or 'anomalous' condition. The anomalous condition was introduced into the experimental procedure to increase the probability of finding limitations or problems with human interactions with the electronic systems. Each subject performed five test runs during a test day: two procedures each with voice and keypad, one with and one without anomalies, and one pen and paper procedure. The data collected were both quantitative (times, errors) and qualitative (subjective ratings of the subjects).

  7. Theoretical Bounds for the Influence of Tissue-Level Ductility on the Apparent-Level Strength of Human Trabecular Bone

    PubMed Central

    Nawathe, Shashank; Juillard, Frédéric; Keaveny, Tony M.

    2015-01-01

    The role of tissue-level post-yield behavior on the apparent-level strength of trabecular bone is a potentially important aspect of bone quality. To gain insight into this issue, we compared the apparent-level strength of trabecular bone for the hypothetical cases of fully brittle versus fully ductile failure behavior of the trabecular tissue. Twenty human cadaver trabecular bone specimens (5 mm cube; BV/TV = 6–36%) were scanned with micro-CT to create 3D finite element models (22-micron element size). For each model, apparent-level strength was computed assuming either fully brittle (fracture with no tissue ductility) or fully ductile (yield with no tissue fracture) tissue-level behaviors. We found that the apparent-level ultimate strength for the brittle behavior was only about half the value of the apparent-level 0.2%-offset yield strength for the ductile behavior, and the ratio of these brittle to ductile strengths was almost constant (mean ± SD = 0.56 ± 0.02; n=20; R2 = 0.99 between the two measures). As a result of this small variation, although the ratio of brittle to ductile strengths was positively correlated with the bone volume fraction (R2=0.44, p=0.01) and structure model index (SMI, R2=0.58, p<0.01), these effects were small. Mechanistically, the fully ductile behavior resulted in a much higher apparent-level strength because in this case about 16-fold more tissue was required to fail than for the fully brittle behavior; also, there was more tensile- than compressive-mode of failure at the tissue level for the fully brittle behavior. We conclude that, in theory, the apparent-level strength behavior of human trabecular bone can vary appreciably depending on whether the tissue fails in a fully ductile versus fully brittle manner, and this effect is largely constant despite appreciable variations in bone volume fraction and microarchitecture. PMID:23497799

  8. How large is the typical subarachnoid hemorrhage? A review of current neurosurgical knowledge.

    PubMed

    Whitmore, Robert G; Grant, Ryan A; LeRoux, Peter; El-Falaki, Omar; Stein, Sherman C

    2012-01-01

    Despite the morbidity and mortality of subarachnoid hemorrhage (SAH), the average volume of a typical hemorrhage is not well defined. Animal models of SAH often do not accurately mimic the human disease process. The purpose of this study is to estimate the average SAH volume, allowing standardization of animal models of the disease. We performed a MEDLINE search of SAH volume and erythrocyte counts in human cerebrospinal fluid as well as for volumes of blood used in animal injection models of SAH, from 1956 to 2010. We polled members of the American Association of Neurological Surgeons (AANS) for estimates of typical SAH volume. Using quantitative data from the literature, we calculated the total volume of SAH as equal to the volume of blood clotted in basal cisterns plus the volume of dispersed blood in cerebrospinal fluid. The results of the AANS poll confirmed our estimates. The human literature yielded 322 publications and animal literature, 237 studies. Four quantitative human studies reported blood clot volumes ranging from 0.2 to 170 mL, with a mean of ∼20 mL. There was only one quantitative study reporting cerebrospinal fluid red blood cell counts from serial lumbar puncture after SAH. Dispersed blood volume ranged from 2.9 to 45.9 mL, and we used the mean of 15 mL for our calculation. Therefore, total volume of SAH equals 35 mL. The AANS poll yielded 176 responses, ranging from 2 to 350 mL, with a mean of 33.9 ± 4.4 mL. Based on our estimate of total SAH volume of 35 mL, animal injection models may now become standardized for more accurate portrayal of the human disease process. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. The Dose-Volume Relationship of Small Bowel Irradiation and Acute Grade 3 Diarrhea During Chemoradiotherapy for Rectal Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robertson, John M.; Lockman, David; Yan Di

    Purpose: Previous work has found a highly significant relationship between the irradiated small-bowel volume and development of Grade 3 small-bowel toxicity in patients with rectal cancer. This study tested the previously defined parameters in a much larger group of patients. Methods and Materials: A total of 96 consecutive patients receiving pelvic radiation therapy for rectal cancer had treatment planning computed tomographic scans with small-bowel contrast that allowed the small bowel to be outlined with calculation of a small-bowel dose-volume histogram for the initial intended pelvic treatment to 45 Gy. Patients with at least one parameter above the previously determined dose-volumemore » parameters were considered high risk, whereas those with all parameters below these levels were low risk. The grade of diarrhea and presence of liquid stool was determined prospectively. Results: There was a highly significant association with small-bowel dose-volume and Grade 3 diarrhea (p {<=} 0.008). The high-risk and low-risk parameters were predictive with Grade 3 diarrhea in 16 of 51 high-risk patients and in 4 of 45 low-risk patients (p = 0.01). Patients who had undergone irradiation preoperatively had a lower incidence of Grade 3 diarrhea than those treated postoperatively (18% vs. 28%; p = 0.31); however, the predictive ability of the high-risk/low-risk parameters was better for preoperatively (p = 0.03) than for postoperatively treated patients (p = 0.15). Revised risk parameters were derived that improved the overall predictive ability (p = 0.004). Conclusions: The highly significant dose-volume relationship and validity of the high-risk and low-risk parameters were confirmed in a large group of patients. The risk parameters provided better modeling for the preoperative patients than for the postoperative patients.« less

  10. Low level CO2 effects on pulmonary function in humans

    NASA Technical Reports Server (NTRS)

    Sexton, J.; Mueller, K.; Elliott, A.; Gerzer, D.; Strohl, K. P.; West, J. B. (Principal Investigator)

    1998-01-01

    The purpose of the study was to determine whether chamber exposure to low levels of CO2 results in functional alterations in gas mixing and closing volume in humans. Four healthy volunteer subjects were exposed to 0.7% CO2 and to 1.2% CO2. Spirometry, lung volumes, single breath nitrogen washout, diffusing capacity for carbon monoxide (DLCO) by two methods, and cardiac output were measured in triplicate. Values were obtained over two non-consecutive days during the training period (control) and on days 2 or 3, 4, 6, 10, 13, and 23 of exposure to each CO2 level. Measurements were made during the same time of day. There was one day of testing after exposure, while still in the chamber but off carbon dioxide. The order of testing, up until measurements of DLCO and cardiac output, were randomized to avoid presentation effects. The consistent findings were a reduction in diffusing capacity for carbon monoxide and a fall in cardiac output, occurring to a similar degree with both exposures. For the group as a whole, there was no indication of major effects on spirometry, lung volumes, gas mixing or dead space. We conclude that small changes may occur in the function of distal gas exchanging units; however, these effects were not associated with any adverse health effects. The likelihood of pathophysiologic changes in lung function or structure with 0.7 or 1.2% CO2 exposure for this period of time, is therefore, low.

  11. Repeated measurements of transfer factor in rabbits: an animal model suitable for evaluation of short-term exposure.

    PubMed

    Dahlqvist, M; Lagerstrand, L; Nilsen, A

    1994-01-01

    Acute temporary changes in lung function may be of use as a biological exposure indicator. However, studies of humans occupationally exposed to complex airborne irritants are often expensive and time demanding. Therefore, an animal model could be a valuable complement. A rabbit model has been evaluated where transfer factor was measured twice during the same day, and with the rabbit awake and available for exposure, in between. Anaesthesia and intubation in 22 rabbits (2.6 [0.2] kg [Mean (SD)]) were immediately followed by two measurements of transfer factor and alveolar volume. Transfer factor was estimated by the single breath CO-technique used in humans. The samples were analysed for CO and He on a gas chromatograph. After one pair of measurements the rabbit was allowed to wake up and after 5 h the duplicate measurements were repeated. The mean values of transfer factor, alveolar volume and transfer constant were 0.50 (0.09) mmol min-1 kPa-1, 127 (8) ml and 3.9 (0.6) mmol min-1 kPa-1 l-1, respectively. The intraindividual coefficients of variation were 7.3%, 5.3% and 6.7%, respectively. Five hours later when the duplicate measurements were repeated, transfer factor, alveolar volume and transfer constant were unchanged still. The results suggest that relatively small changes in transfer factor may be detected without losing power, and thus that this model could be used as a biological exposure indicator.

  12. Implications of improved diagnostic imaging of small nodal metastases in head and neck cancer: Radiotherapy target volume transformation and dose de-escalation.

    PubMed

    van den Bosch, Sven; Vogel, Wouter V; Raaijmakers, Cornelis P; Dijkema, Tim; Terhaard, Chris H J; Al-Mamgani, Abrahim; Kaanders, Johannes H A M

    2018-05-03

    Diagnostic imaging continues to evolve, and now has unprecedented accuracy for detecting small nodal metastasis. This influences the tumor load in elective target volumes and subsequently has consequences for the radiotherapy dose required to control disease in these volumes. Small metastases that used to remain subclinical and were included in elective volumes, will nowadays be detected and included in high-dose volumes. Consequentially, high-dose volumes will more often contain low-volume disease. These target volume transformations lead to changes in the tumor burden in elective and "gross" tumor volumes with implications for the radiotherapy dose prescribed to these volumes. For head and neck tumors, nodal staging has evolved from mere palpation to combinations of high-resolution imaging modalities. A traditional nodal gross tumor volume in the neck typically had a minimum diameter of 10-15 mm, while nowadays much smaller tumor deposits are detected in lymph nodes. However, the current dose levels for elective nodal irradiation were empirically determined in the 1950s, and have not changed since. In this report the radiobiological consequences of target volume transformation caused by modern imaging of the neck are evaluated, and theoretically derived reductions of dose in radiotherapy for head and neck cancer are proposed. The concept of target volume transformation and subsequent strategies for dose adaptation applies to many other tumor types as well. Awareness of this concept may result in new strategies for target definition and selection of dose levels with the aim to provide optimal tumor control with less toxicity. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  13. Spacecraft Habitable Volume: Results of an Interdisciplinary Workshop

    NASA Technical Reports Server (NTRS)

    Fitts, David J.; Connolly, Janis; Howard, Robert

    2011-01-01

    NASA's Human Exploration Framework Team posed the question: "Is 80 cubic meters per person of habitable volume acceptable for a proposed Deep Space Habitat?" The goal of the workshop was to address the "net habitable volume" necessary for long-duration human spaceflight missions and identify design and psychological issues and mitigations. The objectives were: (1) Identify psychological factors -- i.e., "stressors" -- that impact volume and layout specifications for long duration missions (2) Identify mitigation strategies for stressors, especially those that can be written as volume design specifications (3) Identify a forward research roadmap -- i.e., what future work is needed to define and validate objective design metrics? (4) Provide advisories on the human factors consequences of poor net habitable volume allocation and layout design.

  14. 40 CFR 1045.635 - What special provisions apply for small-volume engine manufacturers?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false What special provisions apply for small-volume engine manufacturers? 1045.635 Section 1045.635 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...

  15. 40 CFR 1045.635 - What special provisions apply for small-volume engine manufacturers?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false What special provisions apply for small-volume engine manufacturers? 1045.635 Section 1045.635 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...

  16. 40 CFR 1045.635 - What special provisions apply for small-volume engine manufacturers?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false What special provisions apply for small-volume engine manufacturers? 1045.635 Section 1045.635 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...

  17. 40 CFR 1045.635 - What special provisions apply for small-volume engine manufacturers?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false What special provisions apply for small-volume engine manufacturers? 1045.635 Section 1045.635 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...

  18. 40 CFR 86.1823-08 - Durability demonstration procedures for exhaust emissions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) General Compliance Provisions for Control of Air Pollution From New and In... § 86.1801. Eligible small volume manufacturers or small volume test groups may optionally meet the...

  19. 40 CFR 86.1823-08 - Durability demonstration procedures for exhaust emissions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) General Compliance Provisions for Control of Air Pollution From New and In... § 86.1801. Eligible small volume manufacturers or small volume test groups may optionally meet the...

  20. 40 CFR 86.1824-08 - Durability demonstration procedures for evaporative emissions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... for evaporative emissions. Eligible small-volume manufacturers or small-volume test groups may...-based measurements except the bleed emission test. The standard for bleed emissions applies for the full... manufacturer must conduct at least one evaporative emission test at each of the five different mileage points...

  1. 40 CFR 86.1824-08 - Durability demonstration procedures for evaporative emissions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the applicability provisions of § 86.1801. Eligible small volume manufacturers or small volume test... manufacturer must conduct at least one evaporative emission test at each of the five different mileage points... the highest mileage point run during mileage accumulation (e.g. the full useful life mileage...

  2. 40 CFR 86.094-14 - Small-volume manufacturers certification procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES General Provisions for Emission Regulations for 1977 and Later Model Year New Light-Duty Vehicles, Light...-Fueled, Liquefied Petroleum Gas-Fueled and Methanol-Fueled Heavy-Duty Vehicles § 86.094-14 Small-volume...

  3. 40 CFR 1045.635 - What special provisions apply for small-volume engine manufacturers?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false What special provisions apply for small-volume engine manufacturers? 1045.635 Section 1045.635 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...

  4. 40 CFR 86.095-14 - Small-volume manufacturers certification procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-Fueled, Liquefied Petroleum Gas-Fueled and Methanol-Fueled Heavy-Duty Vehicles § 86.095-14 Small-volume... are exempted from the high altitude emission standards. (18) Proof that the manufacturer has obtained... as proof that the manufacturer has obtained or entered an agreement to purchase the insurance policy...

  5. 40 CFR 86.095-14 - Small-volume manufacturers certification procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-Fueled, Liquefied Petroleum Gas-Fueled and Methanol-Fueled Heavy-Duty Vehicles § 86.095-14 Small-volume... are exempted from the high altitude emission standards. (18) Proof that the manufacturer has obtained... as proof that the manufacturer has obtained or entered an agreement to purchase the insurance policy...

  6. Compilation of 1985 annual reports of the Navy elf (extremely low frequency) communications system ecological monitoring program. Volume 2. Tabs D-G. Annual progress report, January-December 1985

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Band, R.N.; Snider, R.J.; Snider, R.M.

    1986-07-01

    This volume consists of the following reports: Soil Amoeba; Soil and Litter Arthropoda and Earthworm Studies; Biological Studies on Pollinating Insects: Megachilid Bees; Small Vertebrates: Small Mammals and Nesting Birds.

  7. 40 CFR 86.1826-01 - Assigned deterioration factors for small-volume manufacturers and small-volume test groups.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... applying deterioration factors. Manufacturers may use assigned deterioration factors that the Administrator determines and prescribes. (1) The deterioration factors will be the Administrator's estimate, periodically... using the industry-wide database of previously completed durability data vehicles or engines used for...

  8. River Bookends: Headwaters, Delta and the Volumes of Stories in Between

    NASA Astrophysics Data System (ADS)

    Waller, J. L.; Brey, J. A.

    2016-12-01

    As professors of art and earth science, we were often pleased when our students found that integrating lessons of geoscience with art rewarded them in impactful and memorable ways. Inspired by student success and our very real concern for natural and human caused threats to treasured cities and areas on the globe, we produced "Layers: Places in Peril", a gallery exhibition of paintings and scientific explanation essays. We found the combination of art and earth science was a powerful tool that touched and informed a wide and diverse population beyond classrooms. Acutely aware that current crises facing Earth are not limited to gigantic forces, we then produced "small problems, BIG TROUBLE" that addressed how seemingly small problems lead to far-reaching threats. Our conversation expanded to include twenty other scientists from geoscience, biology, physics and chemistry whose science-based essays paired with Waller's paintings. In our newest presentation in production, River Bookends: Headwaters, Delta and the Volumes of Stories in Between, we address art and geo-cultural connections associated with World rivers. Our exploration is focused on rivers as markers of time, culture and identity, yet, the importance of stressing the geoscience in this exhibition is large, indeed. An understanding of geomorphology and river ecology and of the historical changes, both natural and human-engineered which may dramatically give rise to, enrich, distress, or ultimately destroy human settlements and culture, are essential to our intended emphases in the show. In this session, we will describe these exhibitions, show images of the work and discuss some of the gallery activities that resulted from the shows, which included a discussion panel of social science and humanities faculty focused on the exhibition topics. We will describe how local high school art and science students answered our invitation to create a parallel exhibition of our show premise, concurrently exhibited in an adjoining space. We will also show and discuss ways that "River Bookends" is more broadly increasing the collaborations and channels of communication in order to describe our planet and its challenges in ways simultaneously somber and redemptive.

  9. Optimization of Evans blue quantitation in limited rat tissue samples

    PubMed Central

    Wang, Hwai-Lee; Lai, Ted Weita

    2014-01-01

    Evans blue dye (EBD) is an inert tracer that measures plasma volume in human subjects and vascular permeability in animal models. Quantitation of EBD can be difficult when dye concentration in the sample is limited, such as when extravasated dye is measured in the blood-brain barrier (BBB) intact brain. The procedure described here used a very small volume (30 µl) per sample replicate, which enabled high-throughput measurements of the EBD concentration based on a standard 96-well plate reader. First, ethanol ensured a consistent optic path length in each well and substantially enhanced the sensitivity of EBD fluorescence spectroscopy. Second, trichloroacetic acid (TCA) removed false-positive EBD measurements as a result of biological solutes and partially extracted EBD into the supernatant. Moreover, a 1:2 volume ratio of 50% TCA ([TCA final] = 33.3%) optimally extracted EBD from the rat plasma protein-EBD complex in vitro and in vivo, and 1:2 and 1:3 weight-volume ratios of 50% TCA optimally extracted extravasated EBD from the rat brain and liver, respectively, in vivo. This procedure is particularly useful in the detection of EBD extravasation into the BBB-intact brain, but it can also be applied to detect dye extravasation into tissues where vascular permeability is less limiting. PMID:25300427

  10. Optimization of Evans blue quantitation in limited rat tissue samples

    NASA Astrophysics Data System (ADS)

    Wang, Hwai-Lee; Lai, Ted Weita

    2014-10-01

    Evans blue dye (EBD) is an inert tracer that measures plasma volume in human subjects and vascular permeability in animal models. Quantitation of EBD can be difficult when dye concentration in the sample is limited, such as when extravasated dye is measured in the blood-brain barrier (BBB) intact brain. The procedure described here used a very small volume (30 µl) per sample replicate, which enabled high-throughput measurements of the EBD concentration based on a standard 96-well plate reader. First, ethanol ensured a consistent optic path length in each well and substantially enhanced the sensitivity of EBD fluorescence spectroscopy. Second, trichloroacetic acid (TCA) removed false-positive EBD measurements as a result of biological solutes and partially extracted EBD into the supernatant. Moreover, a 1:2 volume ratio of 50% TCA ([TCA final] = 33.3%) optimally extracted EBD from the rat plasma protein-EBD complex in vitro and in vivo, and 1:2 and 1:3 weight-volume ratios of 50% TCA optimally extracted extravasated EBD from the rat brain and liver, respectively, in vivo. This procedure is particularly useful in the detection of EBD extravasation into the BBB-intact brain, but it can also be applied to detect dye extravasation into tissues where vascular permeability is less limiting.

  11. Reproducibility of techniques using Archimedes' principle in measuring cancellous bone volume.

    PubMed

    Zou, L; Bloebaum, R D; Bachus, K N

    1997-01-01

    Researchers have been interested in developing techniques to accurately and reproducibly measure the volume fraction of cancellous bone. Historically bone researchers have used Archimedes' principle with water to measure the volume fraction of cancellous bone. Preliminary results in our lab suggested that the calibrated water technique did not provide reproducible results. Because of this difficulty, it was decided to compare the conventional water method to a water with surfactant and a helium method using a micropycnometer. The water/surfactant and the helium methods were attempts to improve the fluid penetration into the small voids present in the cancellous bone structure. In order to compare the reproducibility of the new methods with the conventional water method, 16 cancellous bone specimens were obtained from femoral condyles of human and greyhound dog femora. The volume fraction measurements on each specimen were repeated three times with all three techniques. The results showed that the helium displacement method was more than an order of magnitudes more reproducible than the two other water methods (p < 0.05). Statistical analysis also showed that the conventional water method produced the lowest reproducibility (p < 0.05). The data from this study indicate that the helium displacement technique is a very useful, rapid and reproducible tool for quantitatively characterizing anisotropic porous tissue structures such as cancellous bone.

  12. Improving the accuracy of ionization chamber dosimetry in small megavoltage x-ray fields

    NASA Astrophysics Data System (ADS)

    McNiven, Andrea L.

    The dosimetry of small x-ray fields is difficult, but important, in many radiation therapy delivery methods. The accuracy of ion chambers for small field applications, however, is limited due to the relatively large size of the chamber with respect to the field size, leading to partial volume effects, lateral electronic disequilibrium and calibration difficulties. The goal of this dissertation was to investigate the use of ionization chambers for the purpose of dosimetry in small megavoltage photon beams with the aim of improving clinical dose measurements in stereotactic radiotherapy and helical tomotherapy. A new method for the direct determination of the sensitive volume of small-volume ion chambers using micro computed tomography (muCT) was investigated using four nominally identical small-volume (0.56 cm3) cylindrical ion chambers. Agreement between their measured relative volume and ionization measurements (within 2%) demonstrated the feasibility of volume determination through muCT. Cavity-gas calibration coefficients were also determined, demonstrating the promise for accurate ion chamber calibration based partially on muCT. The accuracy of relative dose factor measurements in 6MV stereotactic x-ray fields (5 to 40mm diameter) was investigated using a set of prototype plane-parallel ionization chambers (diameters of 2, 4, 10 and 20mm). Chamber and field size specific correction factors ( CSFQ ), that account for perturbation of the secondary electron fluence, were calculated using Monte Carlo simulation methods (BEAM/EGSnrc simulations). These correction factors (e.g. CSFQ = 1.76 (2mm chamber, 5mm field) allow for accurate relative dose factor (RDF) measurement when applied to ionization readings, under conditions of electronic disequilibrium. With respect to the dosimetry of helical tomotherapy, a novel application of the ion chambers was developed to characterize the fan beam size and effective dose rate. Characterization was based on an adaptation of the computed tomography dose index (CTDI), a concept normally used in diagnostic radiology. This involved experimental determination of the fan beam thickness using the ion chambers to acquire fan beam profiles and extrapolation to a 'zero-size' detector. In conclusion, improvements have been made in the accuracy of small field dosimetry measurements in stereotactic radiotherapy and helical tomotherapy. This was completed through introduction of an original technique involving micro-CT imaging for sensitive volume determination and potentially ion chamber calibration coefficients, the use of appropriate Monte Carlo derived correction factors for RDF measurement, and the exploitation of the partial volume effect for helical tomotherapy fan beam dosimetry. With improved dosimetry for a wide range of challenging small x-ray field situations, it is expected that the patient's radiation safety will be maintained, and that clinical trials will adopt calibration protocols specialized for modern radiotherapy with small fields or beamlets. Keywords. radiation therapy, ionization chambers, small field dosimetry, stereotactic radiotherapy, helical tomotherapy, micro-CT.

  13. Computing Evaporation Using Meteorological Data for Hydrological Budget of Lake Wapalanne in NJ School of Conservation

    NASA Astrophysics Data System (ADS)

    Jordan, J. J.; Barrett, K. R.; Galster, J. C.; Ophori, D. U.; Flores, D.; Kelly, S. A.; Lutey, A. M.

    2011-12-01

    Lake Wapalanne is small manmade lake about 5.4 hectares in northwest New Jersey in the Highlands Physiographic province within permanently protected land. The lake's surrounding area consists of forested vegetation and is relatively unoccupied which minimizes human influence. The lake's small size, minimal external influence, geographic isolation, and protected status provide an optimal research environment to record meteorological data used in calculation of potential evaporation. Between July 7h and August 3rd meteorological data was collected from a professional weather station placed on an island directly in the center of Lake Wapalanne. The Vantage Pro2 weather station provided accurate readings of temperate, humidity, wind-speed and direction, precipitation, and atmospheric pressure. A bathometric survey of the lake was conducted to determine the surface area with variations in depth of the lake's water level. Using the collected weather station data, a rate of potential evaporation was determined with several evaporation equations. A quantified volume was then derived from the rate and surface area of the lake. Using small scale evaporation measurements of known volumes of water within small pans placed in the lake water and National Oceanic and Atmospheric Administration evaporation stations near the experiment site, a comparison and validation of the calculated potential evaporation accuracy and regional evaporation is achieved. This three year study is part of an ongoing NSF Research Experience for Undergraduates (REU) project that encompasses additional topics of lake research; see abstract from Kelly et al. AGU 2011 for more information on the lake's hydrologic budget. The results and methods of this study will be of use in future forecasting and baseline measurements of hydrologic budgets for lakes and reservoirs within regional proximity, which provide drinking water to over five million people in the State of New Jersey.

  14. Mucous solids and liquid secretion by airways: studies with normal pig, cystic fibrosis human, and non-cystic fibrosis human bronchi

    PubMed Central

    Martens, Chelsea J.; Inglis, Sarah K.; Valentine, Vincent G.; Garrison, Jennifer; Conner, Gregory E.

    2011-01-01

    To better understand how airways produce thick airway mucus, nonvolatile solids were measured in liquid secreted by bronchi from normal pig, cystic fibrosis (CF) human, and non-CF human lungs. Bronchi were exposed to various secretagogues and anion secretion inhibitors to induce a range of liquid volume secretion rates. In all three groups, the relationship of solids concentration (percent nonvolatile solids) to liquid volume secretion rate was curvilinear, with higher solids concentration associated with lower rates of liquid volume secretion. In contrast, the secretion rates of solids mass and water mass as functions of liquid volume secretion rates exhibited positive linear correlations. The y-intercepts of the solids mass-liquid volume secretion relationships for all three groups were positive, thus accounting for the higher solids concentrations in airway liquid at low rates of secretion. Predictive models derived from the solids mass and water mass linear equations fit the experimental percent solids data for the three groups. The ratio of solids mass secretion to liquid volume secretion was 5.2 and 2.4 times higher for CF bronchi than for pig and non-CF bronchi, respectively. These results indicate that normal pig, non-CF human, and CF human bronchi produce a high-percent-solids mucus (>8%) at low rates of liquid volume secretion (≤1.0 μl·cm−2·h−1). However, CF bronchi produce mucus with twice the percent solids (∼8%) of pig or non-CF human bronchi at liquid volume secretion rates ≥4.0 μl·cm−2·h−1. PMID:21622844

  15. Measuring pedestrian volumes and conflicts. Volume III, Measuring pedestrian volumes : a users manual

    DOT National Transportation Integrated Search

    1988-03-01

    Users of the manual are expected to be in divisions responsible for pedestrian safety in cities, counties, and other jurisdictions. The users manual outlines a step-by-step procedure to measure pedestrian volumes using small count intervals. Appendix...

  16. Human Protein Arginine Methyltransferase 7 (PRMT7) Is a Type III Enzyme Forming ω-NG-Monomethylated Arginine Residues*

    PubMed Central

    Zurita-Lopez, Cecilia I.; Sandberg, Troy; Kelly, Ryan; Clarke, Steven G.

    2012-01-01

    Full-length human protein arginine methyltransferase 7 (PRMT7) expressed as a fusion protein in Escherichia coli was initially found to generate only ω-NG-monomethylated arginine residues in small peptides, suggesting that it is a type III enzyme. A later study, however, characterized fusion proteins of PRMT7 expressed in bacterial and mammalian cells as a type II/type I enzyme, capable of producing symmetrically dimethylated arginine (type II activity) as well as small amounts of asymmetric dimethylarginine (type I activity). We have sought to clarify the enzymatic activity of human PRMT7. We analyzed the in vitro methylation products of a glutathione S-transferase (GST)-PRMT7 fusion protein with robust activity using a variety of arginine-containing synthetic peptides and protein substrates, including a GST fusion with the N-terminal domain of fibrillarin (GST-GAR), myelin basic protein, and recombinant human histones H2A, H2B, H3, and H4. Regardless of the methylation reaction conditions (incubation time, reaction volume, and substrate concentration), we found that PRMT7 only produces ω-NG-monomethylarginine with these substrates. In control experiments, we showed that mammalian GST-PRMT1 and Myc-PRMT5 were, unlike PRMT7, able to dimethylate both peptide P-SmD3 and SmB/D3 to give the expected asymmetric and symmetric products, respectively. These experiments show that PRMT7 is indeed a type III human methyltransferase capable of forming only ω-NG-monomethylarginine, not asymmetric ω-NG,NG-dimethylarginine or symmetric ω-NG,NG′-dimethylarginine, under the conditions tested. PMID:22241471

  17. IVHS Countermeasures for Rear-End Collision, Task 1 Vol. VI: Human Factors Studies

    DOT National Transportation Integrated Search

    1994-02-15

    This report is from the NHTSA sponsored program, "IVHS Countermeasures for Rear-End Collisions". This Volume, Volume VI, Human Factors," presents the results of the initial human factors literature review and study.

  18. “Nanofiltration” Enabled by Super-Absorbent Polymer Beads for Concentrating Microorganisms in Water Samples

    NASA Astrophysics Data System (ADS)

    Xie, Xing; Bahnemann, Janina; Wang, Siwen; Yang, Yang; Hoffmann, Michael R.

    2016-02-01

    Detection and quantification of pathogens in water is critical for the protection of human health and for drinking water safety and security. When the pathogen concentrations are low, large sample volumes (several liters) are needed to achieve reliable quantitative results. However, most microbial identification methods utilize relatively small sample volumes. As a consequence, a concentration step is often required to detect pathogens in natural waters. Herein, we introduce a novel water sample concentration method based on superabsorbent polymer (SAP) beads. When SAP beads swell with water, small molecules can be sorbed within the beads, but larger particles are excluded and, thus, concentrated in the residual non-sorbed water. To illustrate this approach, millimeter-sized poly(acrylamide-co-itaconic acid) (P(AM-co-IA)) beads are synthesized and successfully applied to concentrate water samples containing two model microorganisms: Escherichia coli and bacteriophage MS2. Experimental results indicate that the size of the water channel within water swollen P(AM-co-IA) hydrogel beads is on the order of several nanometers. The millimeter size coupled with a negative surface charge of the beads are shown to be critical in order to achieve high levels of concentration. This new concentration procedure is very fast, effective, scalable, and low-cost with no need for complex instrumentation.

  19. "Nanofiltration" Enabled by Super-Absorbent Polymer Beads for Concentrating Microorganisms in Water Samples.

    PubMed

    Xie, Xing; Bahnemann, Janina; Wang, Siwen; Yang, Yang; Hoffmann, Michael R

    2016-02-15

    Detection and quantification of pathogens in water is critical for the protection of human health and for drinking water safety and security. When the pathogen concentrations are low, large sample volumes (several liters) are needed to achieve reliable quantitative results. However, most microbial identification methods utilize relatively small sample volumes. As a consequence, a concentration step is often required to detect pathogens in natural waters. Herein, we introduce a novel water sample concentration method based on superabsorbent polymer (SAP) beads. When SAP beads swell with water, small molecules can be sorbed within the beads, but larger particles are excluded and, thus, concentrated in the residual non-sorbed water. To illustrate this approach, millimeter-sized poly(acrylamide-co-itaconic acid) (P(AM-co-IA)) beads are synthesized and successfully applied to concentrate water samples containing two model microorganisms: Escherichia coli and bacteriophage MS2. Experimental results indicate that the size of the water channel within water swollen P(AM-co-IA) hydrogel beads is on the order of several nanometers. The millimeter size coupled with a negative surface charge of the beads are shown to be critical in order to achieve high levels of concentration. This new concentration procedure is very fast, effective, scalable, and low-cost with no need for complex instrumentation.

  20. Characterizing Focused-Ultrasound Mediated Drug Delivery to the Heterogeneous Primate Brain In Vivo with Acoustic Monitoring

    NASA Astrophysics Data System (ADS)

    Wu, Shih-Ying; Sanchez, Carlos Sierra; Samiotaki, Gesthimani; Buch, Amanda; Ferrera, Vincent P.; Konofagou, Elisa E.

    2016-11-01

    Focused ultrasound with microbubbles has been used to noninvasively and selectively deliver pharmacological agents across the blood-brain barrier (BBB) for treating brain diseases. Acoustic cavitation monitoring could serve as an on-line tool to assess and control the treatment. While it demonstrated a strong correlation in small animals, its translation to primates remains in question due to the anatomically different and highly heterogeneous brain structures with gray and white matteras well as dense vasculature. In addition, the drug delivery efficiency and the BBB opening volume have never been shown to be predictable through cavitation monitoring in primates. This study aimed at determining how cavitation activity is correlated with the amount and concentration of gadolinium delivered through the BBB and its associated delivery efficiency as well as the BBB opening volume in non-human primates. Another important finding entails the effect of heterogeneous brain anatomy and vasculature of a primate brain, i.e., presence of large cerebral vessels, gray and white matter that will also affect the cavitation activity associated with variation of BBB opening in different tissue types, which is not typically observed in small animals. Both these new findings are critical in the primate brain and provide essential information for clinical applications.

  1. A method for the direct injection and analysis of small volume human blood spots and plasma extracts containing high concentrations of organic solvents using revered-phase 2D UPLC/MS.

    PubMed

    Rainville, Paul D; Simeone, Jennifer L; Root, Dan S; Mallet, Claude R; Wilson, Ian D; Plumb, Robert S

    2015-03-21

    The emergence of micro sampling techniques holds great potential to improve pharmacokinetic data quality, reduce animal usage, and save costs in safety assessment studies. The analysis of these samples presents new challenges for bioanalytical scientists, both in terms of sample processing and analytical sensitivity. The use of two dimensional LC/MS with, at-column-dilution for the direct analysis of highly organic extracts prepared from biological fluids such as dried blood spots and plasma is demonstrated. This technique negated the need to dry down and reconstitute, or dilute samples with water/aqueous buffer solutions, prior to injection onto a reversed-phase LC system. A mixture of model drugs, including bromhexine, triprolidine, enrofloxacin, and procaine were used to test the feasibility of the method. Finally an LC/MS assay for the probe pharmaceutical rosuvastatin was developed from dried blood spots and protein-precipitated plasma. The assays showed acceptable recovery, accuracy and precision according to US FDA guidelines. The resulting analytical method showed an increase in assay sensitivity of up to forty fold as compared to conventional methods by maximizing the amount loaded onto the system and the MS response for the probe pharmaceutical rosuvastatin from small volume samples.

  2. Hand-Held Photometer for Instant On-Spot Quantification of Nucleic Acids, Proteins, and Cells.

    PubMed

    Li, Shi-Hao; Jain, Abhinav; Tscharntke, Timo; Arnold, Tobias; Trau, Dieter W

    2018-02-20

    This paper presents a novel hand-held photometer, termed "Photopette", for on-spot absorbance measurements of biochemical analytes. The Photopette is a multicomponent, highly portable device with an overall weight of 160 g, which fits within 202 mm × 47 mm × 42 mm. Designed in the form factor of a micropipette, Photopette integrates a photodiode detector with light emitting diodes (LEDs) to form a highly customizable photometer which supports a wide variety of applications within the wavelengths between 260 and 1050 nm. A dual-purpose disposable reflective tip was designed to act as a sample holder and a light-reflecting system, which is in stark contrast to the operation of mainstream spectrophotometers and photometers. Small volume analytes may be measured with low sample loss using this proprietary CuveTip. A user-friendly software application running on smart devices was developed to control and read the values from Photopette via a low-energy Bluetooth link. This one-step strategy allows measurements on-spot without sample transfer, minimizing cross-contamination and human error. The results reported in this paper demonstrate Photopette's great potential to quantify DNA, direct protein, and cell density directly within the laminar flow hood. Results are compared with a Nanodrop 2000c spectrophotometer, a mainstream spectrophotometer for small-volume measurements.

  3. Characterizing Focused-Ultrasound Mediated Drug Delivery to the Heterogeneous Primate Brain In Vivo with Acoustic Monitoring

    PubMed Central

    Wu, Shih-Ying; Sanchez, Carlos Sierra; Samiotaki, Gesthimani; Buch, Amanda; Ferrera, Vincent P.; Konofagou, Elisa E.

    2016-01-01

    Focused ultrasound with microbubbles has been used to noninvasively and selectively deliver pharmacological agents across the blood-brain barrier (BBB) for treating brain diseases. Acoustic cavitation monitoring could serve as an on-line tool to assess and control the treatment. While it demonstrated a strong correlation in small animals, its translation to primates remains in question due to the anatomically different and highly heterogeneous brain structures with gray and white matteras well as dense vasculature. In addition, the drug delivery efficiency and the BBB opening volume have never been shown to be predictable through cavitation monitoring in primates. This study aimed at determining how cavitation activity is correlated with the amount and concentration of gadolinium delivered through the BBB and its associated delivery efficiency as well as the BBB opening volume in non-human primates. Another important finding entails the effect of heterogeneous brain anatomy and vasculature of a primate brain, i.e., presence of large cerebral vessels, gray and white matter that will also affect the cavitation activity associated with variation of BBB opening in different tissue types, which is not typically observed in small animals. Both these new findings are critical in the primate brain and provide essential information for clinical applications. PMID:27853267

  4. “Nanofiltration” Enabled by Super-Absorbent Polymer Beads for Concentrating Microorganisms in Water Samples

    PubMed Central

    Xie, Xing; Bahnemann, Janina; Wang, Siwen; Yang, Yang; Hoffmann, Michael R.

    2016-01-01

    Detection and quantification of pathogens in water is critical for the protection of human health and for drinking water safety and security. When the pathogen concentrations are low, large sample volumes (several liters) are needed to achieve reliable quantitative results. However, most microbial identification methods utilize relatively small sample volumes. As a consequence, a concentration step is often required to detect pathogens in natural waters. Herein, we introduce a novel water sample concentration method based on superabsorbent polymer (SAP) beads. When SAP beads swell with water, small molecules can be sorbed within the beads, but larger particles are excluded and, thus, concentrated in the residual non-sorbed water. To illustrate this approach, millimeter-sized poly(acrylamide-co-itaconic acid) (P(AM-co-IA)) beads are synthesized and successfully applied to concentrate water samples containing two model microorganisms: Escherichia coli and bacteriophage MS2. Experimental results indicate that the size of the water channel within water swollen P(AM-co-IA) hydrogel beads is on the order of several nanometers. The millimeter size coupled with a negative surface charge of the beads are shown to be critical in order to achieve high levels of concentration. This new concentration procedure is very fast, effective, scalable, and low-cost with no need for complex instrumentation. PMID:26876979

  5. Doppler velocity measurements from large and small arteries of mice

    PubMed Central

    Reddy, Anilkumar K.; Madala, Sridhar; Entman, Mark L.; Michael, Lloyd H.; Taffet, George E.

    2011-01-01

    With the growth of genetic engineering, mice have become increasingly common as models of human diseases, and this has stimulated the development of techniques to assess the murine cardiovascular system. Our group has developed nonimaging and dedicated Doppler techniques for measuring blood velocity in the large and small peripheral arteries of anesthetized mice. We translated technology originally designed for human vessels for use in smaller mouse vessels at higher heart rates by using higher ultrasonic frequencies, smaller transducers, and higher-speed signal processing. With these methods one can measure cardiac filling and ejection velocities, velocity pulse arrival times for determining pulse wave velocity, peripheral blood velocity and vessel wall motion waveforms, jet velocities for the calculation of the pressure drop across stenoses, and left main coronary velocity for the estimation of coronary flow reserve. These noninvasive methods are convenient and easy to apply, but care must be taken in interpreting measurements due to Doppler sample volume size and angle of incidence. Doppler methods have been used to characterize and evaluate numerous cardiovascular phenotypes in mice and have been particularly useful in evaluating the cardiac and vascular remodeling that occur following transverse aortic constriction. Although duplex ultrasonic echo-Doppler instruments are being applied to mice, dedicated Doppler systems are more suitable for some applications. The magnitudes and waveforms of blood velocities from both cardiac and peripheral sites are similar in mice and humans, such that much of what is learned using Doppler technology in mice may be translated back to humans. PMID:21572013

  6. 40 CFR 94.209 - Special provisions for post-manufacture marinizers and small-volume manufacturers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-manufacture marinizers and small-volume manufacturers. 94.209 Section 94.209 Protection of Environment... COMPRESSION-IGNITION ENGINES Certification Provisions § 94.209 Special provisions for post-manufacture... demonstrate one of the following: (1) It is a post-manufacture marinizer and that the base engines used for...

  7. Measuring Very Small Quantities: Fascinating Suggestions for Math or Science.

    ERIC Educational Resources Information Center

    Thompson, John Taylor

    1989-01-01

    Described are several activities for teaching children to determine mass and volume. Included are the masses of a water drop and a grain of rice; the volume of a water drop and small solids; and measuring the width of a hair. Procedures and materials for the activities are discussed. (CW)

  8. Basics of Sterile Compounding: Particulate Matter.

    PubMed

    Akers, Michael J

    2017-01-01

    This article focuses on the requirements for particulate matter in sterile products. Topics include particles and quality, particulate matter standards (large- and small-volume injectables), development of the small-volume injectable test, electronic (light obscuration) and microscope testing, and special requirements for particulate matter in biopharmaceutical preparations. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  9. 40 CFR 86.1838-01 - Small-volume manufacturer certification procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES General Compliance Provisions for Control of Air Pollution From New and In-Use Light-Duty Vehicles, Light-Duty Trucks, and Complete Otto-Cycle Heavy-Duty Vehicles § 86.1838-01 Small-volume manufacturer...

  10. Influence of parental care on offspring hippocampal volume in young adults varies as a function of overprotection.

    PubMed

    Wang, Yinan; Song, Yiying; Li, Xueting; Zhang, Lin; Liu, Jia

    2017-04-12

    Parental care results in increased hippocampal volumes through adaptive stress responses in developing animals. However, human studies have not yet provided consistent findings analogous to the animal literature, possibly because parental care in humans is likely intermingled with parental overprotection, as suggested by the optimal parenting theory. Here, we tested the hypothesis that the effect of parental care on offspring hippocampal volume varies as a function of parental overprotection with a large cohort of young adult participants (N = 257). Consistent with some previous human studies, we found that parental care in childhood alone had little association with the hippocampal volume in adulthood. However, when parental overprotection was low, parental care was positively correlated with offspring hippocampal volume, whereas there was no association between parental care and offspring hippocampal volume when parental overprotection was high. Thus, an interaction exists between parental care and overprotection in human's hippocampal development, which contributes to the elucidation of the complex relationship between brain structure and environmental factors.

  11. Non-Invasive Electromagnetic Skin Patch Sensor to Measure Intracranial Fluid–Volume Shifts

    PubMed Central

    Griffith, Jacob; Cluff, Kim; Eckerman, Brandon; Aldrich, Jessica; Becker, Ryan; Moore-Jansen, Peer; Patterson, Jeremy

    2018-01-01

    Elevated intracranial fluid volume can drive intracranial pressure increases, which can potentially result in numerous neurological complications or death. This study’s focus was to develop a passive skin patch sensor for the head that would non-invasively measure cranial fluid volume shifts. The sensor consists of a single baseline component configured into a rectangular planar spiral with a self-resonant frequency response when impinged upon by external radio frequency sweeps. Fluid volume changes (10 mL increments) were detected through cranial bone using the sensor on a dry human skull model. Preliminary human tests utilized two sensors to determine feasibility of detecting fluid volume shifts in the complex environment of the human body. The correlation between fluid volume changes and shifts in the first resonance frequency using the dry human skull was classified as a second order polynomial with R2 = 0.97. During preliminary and secondary human tests, a ≈24 MHz and an average of ≈45.07 MHz shifts in the principal resonant frequency were measured respectively, corresponding to the induced cephalad bio-fluid shifts. This electromagnetic resonant sensor may provide a non-invasive method to monitor shifts in fluid volume and assist with medical scenarios including stroke, cerebral hemorrhage, concussion, or monitoring intracranial pressure. PMID:29596338

  12. A Study on Estimation on Flood Warning Trigger Rainfall in medium and small Stream Affected by Urban Effects

    NASA Astrophysics Data System (ADS)

    Youngseok, Song; Moojong, Park; JungHo, Lee; HeeSup, Lee

    2013-04-01

    As extreme floods occur frequently in recent years due to global climate changes, an in sudden local flooding of great volume and short duration is becoming the significant danger and loss of life and property in the Korean Peninsula as well as most parts of the world. The desire for living without hazardous damages grows these days, the city strategy to make the safer community has become an issue. Previously most of flood prevention efforts have been made for relatively large watersheds near to channel flow. However, as economical development and the expansion of city near medium and small stream, human casualty and property by flood occurs frequently. Therefore, to reduce the damage of human lives and property by flood, we develop an assessment method for flood warning trigger rainfall considering urban effect. Considering complex land use, HEC-HMS is used for rural area and SWMM is adopted for sewer networks runoff. And relationship between runoff and stream water level, HEC-RAS is accompanied with runoff results. Proposed flood warning trigger rainfall assessment method shows good agreement with gauged data and could be used for another case to mitigate damage. Acknowledgement: "This research was supported by a grant [NEMA-NH-2011-45] from the Natural Hazard Mitigation Research Group, National Emergency Management Agency of Korea." Keyword: HEC-HMS, HEC-RAS, critical precipitation, medium and small stream

  13. Autologus or allogenic uses of umbilical cord blood whole or RBC transfusion - a review.

    PubMed

    Chakrabarty, P; Rudra, S

    2013-01-01

    Once Umbilical Cord with Placenta considered a biological waste product and generally discarded after delivery but now cord blood has emerged as a viable source of hematopoietic stem cell transplantation. High-risk premature infants require red cell transfusions for anemia. A unique property of cord blood (CB) for its high content of immature hematopoietic progenitor cells (HPCs). Placental blood for autologous transfusions can be collected with aseptic precaution/sterilely into citrate-phosphate-dextrose and stored at 4°C. During storage for 8 days, the placental red cell content of adenosine triphosphate remained normal. The 2,3,-diphosphoglycerate concentration of cells stored beyond 8 days declined sharply. So we have to store umbilical cord blood (UCB) within 7 days for its best result. During storage, placental blood underwent an exchange of extra-cellular Na+ and K+, but no change in glutathione content. Hemolysis was less than 1 percent. Bacteriologic and fungal cultures remained sterile. These suggest that human placental blood can be collected safely and preserved effectively for autologous/allogenic transfusion therapy. In neonatal transfusion practice, efforts have been made to provide premature infants with autologous red blood cell (RBC), especially those born before 32 gestational weeks. In India no adverse transfusion effects were seen in a wide variety of patients that received (pooled) allogeneic fresh whole blood / UCB transfusions. The use of UCB for small volume allogeneic transfusions in anaemic children in Africa or in malaria endemic areas has also been proposed. A preclinical study showed that donation and transfusion of UCB would be acceptable to women living in Mombasa, Kenya. In view of the small volumes RBC per unit that can be collected, it is most likely that anaemic children need of a small volume of transfusions. In resource-restricted countries would benefit most from this easily available transfusion product.

  14. Photoacoustic imaging: a potential new tool for arthritis

    NASA Astrophysics Data System (ADS)

    Wang, Xueding

    2012-12-01

    The potential application of photoacoustic imaging (PAI) technology to diagnostic imaging and therapeutic monitoring of inflammatory arthritis has been explored. The feasibility of our bench-top joint imaging systems in delineating soft articular tissue structures in a noninvasive manner was validated first on rat models and then on human peripheral joints. Based on the study on commonly used arthritis rat models, the capability of PAI to differentiate arthritic joints from the normal was also examined. With sufficient imaging depth, PAI can realize tomographic imaging of a human peripheral joint or a small-animal joint as a whole organ noninvasively. By presenting additional optical contrast and tissue functional information such as blood volume and blood oxygen saturation, PAI may provide an opportunity for early diagnosis of inflammatory joint disorders, e.g. rheumatoid arthritis, and for monitoring of therapeutic outcomes with improved sensitivity and accuracy.

  15. A Comparative Study of Serum Exosome Isolation Using Differential Ultracentrifugation and Three Commercial Reagents.

    PubMed

    Helwa, Inas; Cai, Jingwen; Drewry, Michelle D; Zimmerman, Arthur; Dinkins, Michael B; Khaled, Mariam Lotfy; Seremwe, Mutsa; Dismuke, W Michael; Bieberich, Erhard; Stamer, W Daniel; Hamrick, Mark W; Liu, Yutao

    2017-01-01

    Exosomes play a role in cell-to-cell signaling and serve as possible biomarkers. Isolating exosomes with reliable quality and substantial concentration is a major challenge. Our purpose is to compare the exosomes extracted by three different exosome isolation kits (miRCURY, ExoQuick, and Invitrogen Total Exosome Isolation Reagent) and differential ultracentrifugation (UC) using six different volumes of a non-cancerous human serum (5 ml, 1 ml, 500 μl, 250 μl, 100 μl, and 50 μl) and three different volumes (1 ml, 500 μl and 100 μl) of six individual commercial serum samples collected from human donors. The smaller starting volumes (100 μl and 50 μl) are used to mimic conditions of limited availability of heterogeneous biological samples. The isolated exosomes were characterized based upon size, quantity, zeta potential, CD63 and CD9 protein expression, and exosomal RNA (exRNA) quality and quantity using several complementary methods: nanoparticle tracking analysis (NTA) with ZetaView, western blot, transmission electron microscopy (TEM), the Agilent Bioanalyzer system, and droplet digital PCR (ddPCR). Our NTA results showed that all isolation techniques produced exosomes within the expected size range (40-150 nm). The three kits, though, produced a significantly higher yield (80-300 fold) of exosomes as compared to UC for all serum volumes, except 5 mL. We also found that exosomes isolated by the different techniques and serum volumes had similar zeta potentials to previous studies. Western blot analysis and TEM immunogold labelling confirmed the expression of two common exosomal protein markers, CD63 and CD9, in samples isolated by all techniques. All exosome isolations yielded high quality exRNA, containing mostly small RNA with a peak between 25 and 200 nucleotides in size. ddPCR results indicated that exosomes isolated from similar serum volumes but different isolation techniques rendered similar concentrations of two selected exRNA: hsa-miR-16 and hsa-miR-451. In summary, the three commercial exosome isolation kits are viable alternatives to UC, even when limited amounts of biological samples are available.

  16. Boundary Element Method in a Self-Gravitating Elastic Half-Space and Its Application to Deformation Induced by Magma Chambers

    NASA Astrophysics Data System (ADS)

    Fang, M.; Hager, B. H.

    2014-12-01

    In geophysical applications the boundary element method (BEM) often carries the essential physics in addition to being an efficient numerical scheme. For use of the BEM in a self-gravitating uniform half-space, we made extra effort and succeeded in deriving the fundamental solution analytically in closed-form. A problem that goes deep into the heart of the classic BEM is encountered when we try to apply the new fundamental solution in BEM for deformation field induced by a magma chamber or a fluid-filled reservoir. The central issue of the BEM is the singular integral arising from determination of the boundary values. A widely employed technique is to rescale the singular boundary point into a small finite volume and then shrink it to extract the limits. This operation boils down to the calculation of the so-called C-matrix. Authors in the past take the liberty of either adding or subtracting a small volume. By subtracting a small volume, the C-matrix is (1/2)I on a smooth surface, where I is the identity matrix; by adding a small volume, we arrive at the same C-matrix in the form of I - (1/2)I. This evenness is a result of the spherical symmetry of Kelvin's fundamental solution employed. When the spherical symmetry is broken by gravity, the C-matrix is polarized. And we face the choice between right and wrong, for adding and subtracting a small volume yield different C-matrices. Close examination reveals that both derivations, addition and subtraction of a small volume, are ad hoc. To resolve the issue we revisit the Somigliana identity with a new derivation and careful step-by-step anatomy. The result proves that even though both adding and subtracting a small volume appear to twist the original boundary, only addition essentially modifies the original boundary and consequently modifies the physics of the original problem in a subtle way. The correct procedure is subtraction. We complete a new BEM theory by introducing in full analytical form what we call the singular stress tensor for the fundamental solution. We partition the stress tensor of the fundamental solution into a singular part and a regular part. In this way all singular integrals systematically shift into the easy singular stress tensor. Applications of this new BEM to deformation and gravitational perturbation induced by magma chambers of finite volume will be presented.

  17. Performance of viruses and bacteriophages for fecal source determination in a multi-laboratory, comparative study.

    PubMed

    Harwood, Valerie J; Boehm, Alexandria B; Sassoubre, Lauren M; Vijayavel, Kannappan; Stewart, Jill R; Fong, Theng-Theng; Caprais, Marie-Paule; Converse, Reagan R; Diston, David; Ebdon, James; Fuhrman, Jed A; Gourmelon, Michele; Gentry-Shields, Jennifer; Griffith, John F; Kashian, Donna R; Noble, Rachel T; Taylor, Huw; Wicki, Melanie

    2013-11-15

    An inter-laboratory study of the accuracy of microbial source tracking (MST) methods was conducted using challenge fecal and sewage samples that were spiked into artificial freshwater and provided as unknowns (blind test samples) to the laboratories. The results of the Source Identification Protocol Project (SIPP) are presented in a series of papers that cover 41 MST methods. This contribution details the results of the virus and bacteriophage methods targeting human fecal or sewage contamination. Human viruses used as source identifiers included adenoviruses (HAdV), enteroviruses (EV), norovirus Groups I and II (NoVI and NoVII), and polyomaviruses (HPyVs). Bacteriophages were also employed, including somatic coliphages and F-specific RNA bacteriophages (FRNAPH) as general indicators of fecal contamination. Bacteriophage methods targeting human fecal sources included genotyping of FRNAPH isolates and plaque formation on bacterial hosts Enterococcus faecium MB-55, Bacteroides HB-73 and Bacteroides GB-124. The use of small sample volumes (≤50 ml) resulted in relatively insensitive theoretical limits of detection (10-50 gene copies or plaques × 50 ml(-1)) which, coupled with low virus concentrations in samples, resulted in high false-negative rates, low sensitivity, and low negative predictive values. On the other hand, the specificity of the human virus methods was generally close to 100% and positive predictive values were ∼40-70% with the exception of NoVs, which were not detected. The bacteriophage methods were generally much less specific toward human sewage than virus methods, although FRNAPH II genotyping was relatively successful, with 18% sensitivity and 85% specificity. While the specificity of the human virus methods engenders great confidence in a positive result, better concentration methods and larger sample volumes must be utilized for greater accuracy of negative results, i.e. the prediction that a human contamination source is absent. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Image quality metrics for volumetric laser displays

    NASA Astrophysics Data System (ADS)

    Williams, Rodney D.; Donohoo, Daniel

    1991-08-01

    This paper addresses the extensions to the image quality metrics and related human factors research that are needed to establish the baseline standards for emerging volume display technologies. The existing and recently developed technologies for multiplanar volume displays are reviewed with an emphasis on basic human visual issues. Human factors image quality metrics and guidelines are needed to firmly establish this technology in the marketplace. The human visual requirements and the display design tradeoffs for these prototype laser-based volume displays are addressed and several critical image quality issues identified for further research. The American National Standard for Human Factors Engineering of Visual Display Terminal Workstations (ANSIHFS-100) and other international standards (ISO, DIN) can serve as a starting point, but this research base must be extended to provide new image quality metrics for this new technology for volume displays.

  19. Echocardiography underestimates stroke volume and aortic valve area: implications for patients with small-area low-gradient aortic stenosis.

    PubMed

    Chin, Calvin W L; Khaw, Hwan J; Luo, Elton; Tan, Shuwei; White, Audrey C; Newby, David E; Dweck, Marc R

    2014-09-01

    Discordance between small aortic valve area (AVA; < 1.0 cm(2)) and low mean pressure gradient (MPG; < 40 mm Hg) affects a third of patients with moderate or severe aortic stenosis (AS). We hypothesized that this is largely due to inaccurate echocardiographic measurements of the left ventricular outflow tract area (LVOTarea) and stroke volume alongside inconsistencies in recommended thresholds. One hundred thirty-three patients with mild to severe AS and 33 control individuals underwent comprehensive echocardiography and cardiovascular magnetic resonance imaging (MRI). Stroke volume and LVOTarea were calculated using echocardiography and MRI, and the effects on AVA estimation were assessed. The relationship between AVA and MPG measurements was then modelled with nonlinear regression and consistent thresholds for these parameters calculated. Finally the effect of these modified AVA measurements and novel thresholds on the number of patients with small-area low-gradient AS was investigated. Compared with MRI, echocardiography underestimated LVOTarea (n = 40; -0.7 cm(2); 95% confidence interval [CI], -2.6 to 1.3), stroke volumes (-6.5 mL/m(2); 95% CI, -28.9 to 16.0) and consequently, AVA (-0.23 cm(2); 95% CI, -1.01 to 0.59). Moreover, an AVA of 1.0 cm(2) corresponded to MPG of 24 mm Hg based on echocardiographic measurements and 37 mm Hg after correction with MRI-derived stroke volumes. Based on conventional measures, 56 patients had discordant small-area low-gradient AS. Using MRI-derived stroke volumes and the revised thresholds, a 48% reduction in discordance was observed (n = 29). Echocardiography underestimated LVOTarea, stroke volume, and therefore AVA, compared with MRI. The thresholds based on current guidelines were also inconsistent. In combination, these factors explain > 40% of patients with discordant small-area low-gradient AS. Copyright © 2014 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  20. The Human as a System - Monitoring Spacecraft Net Habitable Volume throughout the Design Lifecycle

    NASA Technical Reports Server (NTRS)

    Szabo, Richard; Kallay, Anna; Twyford, Evan; Maida, Jim

    2007-01-01

    Spacecraft design has historically allocated specific volume and mass "not to exceed" requirements upon individual systems and their accompanying hardware (e.g., life support, avionics) early in their conceptual design in an effort to align the spacecraft with propulsion capabilities. If the spacecraft is too heavy or too wide for the launch stack - it does not get off the ground. This approach has predictably ended with the crew being allocated whatever open, pressurized volume remains. With the recent inauguration of a new human-rated spacecraft - NASA human factors personnel have found themselves in the unique position to redefine the human as a system from the very foundation of design. They seek to develop and monitor a "not to fall below" requirement for crew net habitable volume (NHV) - balanced against the "not to exceed" system volume requirements, with the spacecraft fitting the crew versus the crew having to fit inside the spacecraft.

  1. Object strength--an accurate measure for small objects that is insensitive to partial volume effects.

    PubMed

    Tofts, P S; Silver, N C; Barker, G J; Gass, A

    2005-07-01

    There are currently four problems in characterising small nonuniform lesions or other objects in Magnetic Resonance images where partial volume effects are significant. Object size is over- or under-estimated; boundaries are often not reproducible; mean object value cannot be measured; and fuzzy borders cannot be accommodated. A new measure, Object Strength, is proposed. This is the sum of all abnormal intensities, above a uniform background value. For a uniform object, this is simply the product of the increase in intensity and the size of the object. Biologically, this could be at least as relevant as existing measures of size or mean intensity. We hypothesise that Object Strength will perform better than traditional area measurements in characterising small objects. In a pilot study, the reproducibility of object strength measurements was investigated using MR images of small multiple sclerosis (MS) lesions. In addition, accuracy was investigated using artificial lesions of known volume (0.3-6.2 ml) and realistic appearance. Reproducibility approached that of area measurements (in 33/90 lesion reports the difference between repeats was less than for area measurements). Total lesion volume was accurate to 0.2%. In conclusion, Object Strength has potential for improved characterisation of small lesions and objects in imaging and possibly spectroscopy.

  2. Age-Based Comparison of Human Dendritic Spine Structure Using Complete Three-Dimensional Reconstructions

    PubMed Central

    Benavides-Piccione, Ruth; Fernaud-Espinosa, Isabel; Robles, Victor; Yuste, Rafael; DeFelipe, Javier

    2013-01-01

    Dendritic spines of pyramidal neurons are targets of most excitatory synapses in the cerebral cortex. Recent evidence suggests that the morphology of the dendritic spine could determine its synaptic strength and learning rules. However, unfortunately, there are scant data available regarding the detailed morphology of these structures for the human cerebral cortex. In the present study, we analyzed over 8900 individual dendritic spines that were completely 3D reconstructed along the length of apical and basal dendrites of layer III pyramidal neurons in the cingulate cortex of 2 male humans (aged 40 and 85 years old), using intracellular injections of Lucifer Yellow in fixed tissue. We assembled a large, quantitative database, which revealed a major reduction in spine densities in the aged case. Specifically, small and short spines of basal dendrites and long spines of apical dendrites were lost, regardless of the distance from the soma. Given the age difference between the cases, our results suggest selective alterations in spines with aging in humans and indicate that the spine volume and length are regulated by different biological mechanisms. PMID:22710613

  3. An automatic rat brain extraction method based on a deformable surface model.

    PubMed

    Li, Jiehua; Liu, Xiaofeng; Zhuo, Jiachen; Gullapalli, Rao P; Zara, Jason M

    2013-08-15

    The extraction of the brain from the skull in medical images is a necessary first step before image registration or segmentation. While pre-clinical MR imaging studies on small animals, such as rats, are increasing, fully automatic imaging processing techniques specific to small animal studies remain lacking. In this paper, we present an automatic rat brain extraction method, the Rat Brain Deformable model method (RBD), which adapts the popular human brain extraction tool (BET) through the incorporation of information on the brain geometry and MR image characteristics of the rat brain. The robustness of the method was demonstrated on T2-weighted MR images of 64 rats and compared with other brain extraction methods (BET, PCNN, PCNN-3D). The results demonstrate that RBD reliably extracts the rat brain with high accuracy (>92% volume overlap) and is robust against signal inhomogeneity in the images. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Putting HR outsourcing into practice.

    PubMed

    Berger, Michael

    2007-01-01

    Faced with the time-consuming responsibility of human resources (HR) management, a growing number of medical practices are outsourcing their HR to professional employer organizations (PEOs) so they can concentrate on their core business. A PEO functions as an HR department-minus the high overhead-managing daily administrative tasks such as payroll processing and related tax filings, employee benefits, and workers' compensation coverage and claims resolution. PEOs help physicians' offices keep up with the piles of paperwork that never seem to shrink, freeing doctors to focus on patient care and building their practice. Because of their volume buying power, PEOs are able to offer employees of small medical practices big-company benefits-everything from health, dental, and vision coverage to long-term disability insurance and tuition assistance. A fledgling industry only a decade ago, HR outsourcing has morphed into a blossoming industry. Enlisting the services of a PEO is now considered de rigueur in many small business circles.

  5. Dual-frequency ultrasound focal therapy for MRI-guided transurethral treatment of the prostate: Study in gel phantom

    NASA Astrophysics Data System (ADS)

    N'Djin, W. Apoutou; Mougenot, Charles; Kobelevskiy, Ilya; Ramsay, Elizabeth; Bronskill, Michael; Chopra, Rajiv

    2012-11-01

    Ultrasound thermal therapy of localized prostate cancer offers a minimally-invasive non-ionizing alternative [1-3] to surgery and radiotherapy. MRI-controlled transurethral ultrasound prostate therapy [4-6] has previously been investigated in a pilot human feasibility study [7], by treating a small sub-volume of prostate tissue. In this study, the feasibility of transurethral dual-frequency ultrasound focal therapy has been investigated in gel phantom. A database of pelvic anatomical models of human prostate cancer patients have been created using MR clinical images. The largest prostate boundary (47 cm3) was used to fabricate an anatomical gel phantom which included various MR characteristics to mimic prostate tissues, 4 localized tumors and surrounding prostate tissues. A 9-element transurethral ultrasound applicator working in dual-frequency mode (f = 4.6/14.5 MHz) was evaluated to heat: (i) the entire prostate volume (Full prostate treatment strategy), (ii) a prostate region restricted to tumors (Focal therapy). Acoustic power of each element and rotation rate of the device were adjusted in realtime based on MR-thermometry feedback control (nine thermal slices updated every 6.2s). Experiments have been performed using dual-frequency ultrasound exposures (surface Pmax: 20W.cm-2). (i) For full prostate heating, 7 elements of the device were used to cover the entire prostate length. The heating process was completed within 35 min. Ultrasound exposures at the fundamental frequency allowed full heating of the largest prostate radii (>18 mm), while exposures at the 3rd harmonic ensured homogeneous treatment of the smallest radii. Undertreated and overtreated regions represented respectively 2% and 17% of the prostate volume. (ii) For focal therapy, the target region was optimized to maintain safe regions in the prostate and to cover all tumor-mimics. Only 5 ultrasound elements were used to treat successfully all tumor-mimics within 26 min. Undertreated and overtreated regions each represented 7% of the prostate volume. MRI-guided transurethral ultrasound procedure enables full treatment and focal therapy in human prostate geometry. Prostate volume heating was fast compared to standard HIFU prostate treatments. Dual-frequency ultrasound exposures allowed optimal heat deposition in all prostate regions. The focal therapy strategy is promising as regard to safety and could contribute to enhance the post-treatment autonomy of the patient.

  6. CT Evolution of Hematoma and Surrounding Hypodensity in a Cadaveric Model of Intracerebral Hemorrhage.

    PubMed

    Majidi, Shahram; Rahim, Basit; Gilani, Sarwat I; Gilani, Waqas I; Adil, Malik M; Qureshi, Adnan I

    2016-05-01

    The evolution of intracerebral hematoma and perihematoma edema in the ultra-early period on computed tomographic (CT) scans in patients with intracerebral hemorrhage (ICH) is not well understood. We aimed to investigate hematoma and perihematoma changes in "neutral brain" models of ICH. One human and five goat cadaveric heads were used as "neutral brains" to provide physical properties of brain without any biological activity or new bleeding. ICH was induced by slow injection of 4 ml of fresh human blood into the right basal ganglia of the goat brains. Similarly, 20 ml of fresh blood was injected deep into the white matter of the human cadaver head in each hemisphere. Serial CT scans of the heads were obtained immediately after hematoma induction and then 1, 3, and 5 hours afterward. Analyze software (AnalyzeDirect, Overland Park, KS, USA) was used to measure hematoma and perihematoma hypodensity volumes in the baseline and follow-up CT scans. The initial hematoma volumes of 11.6 ml and 10.5 ml in the right and left hemispheres of the cadaver brains gradually decreased to 6.6 ml and 5.4 ml at 5 hours, showing 43% and 48% retraction of hematoma, respectively. The volume of the perihematoma hypodensity in the right and left hemisphere increased from 2.6 ml and 2.2 ml in the 1-hour follow-up CT scans to 4.9 ml and 4.4 ml in the 5-hour CT scan, respectively. Hematoma retraction was also observed in all five goat brains ICH models with the mean ICH volume decreasing from 1.49 ml at baseline scan to 1.01 ml at the 5-hour follow-up CT scan (29.6% hematoma retraction). Perihematoma hypodensity was visualized in 70% of ICH in goat brains, with an increasing mean hypodensity volume of 0.4 ml in the baseline CT scan to 0.8 ml in the 5-hour follow-up CT scan. Our study demonstrated that substantial hematoma retraction and perihematoma hypodensity occurs in ICH in the absence of any new bleeding or biological activity of surrounding brain. Such observations suggest that active bleeding is underestimated in patients with no or small hematoma expansion and our understanding of perihematoma hypodensity needs to be reconsidered. Copyright © 2015 by the American Society of Neuroimaging.

  7. Re-188 Enhances the Inhibitory Effect of Bevacizumab in Non-Small-Cell Lung Cancer.

    PubMed

    Xiao, Jie; Xu, Xiaobo; Li, Xiao; Li, Yanli; Liu, Guobing; Tan, Hui; Shen, Hua; Shi, Hongcheng; Cheng, Dengfeng

    2016-09-30

    The malignant behaviors of solid tumors such as growth, infiltration and metastasis are mainly nourished by tumor neovascularization. Thus, anti-angiogenic therapy is key to controlling tumor progression. Bevacizumab, a humanized anti-vascular endothelial growth factor (VEGF) antibody, plus chemotherapy or biological therapy can prolong survival for cancer patients, but treatment-related mortality is a concern. To improve inhibitory effect and decrease side-effects on non-small-cell lung cancer (NSCLC), we used Re-188, which is a β emitting radionuclide, directly labeled with bevacizumab for radioimmunotherapy in a human A549 tumor model. Cytotoxic assay data showed that, after 188 ReO₄ - or 188 Re-bevacizumab at different concentration for 4 and 24 h, a time- and radioactivity does-dependent reduction in cell viability occurred. Also, an apoptosis assay conformed great apoptosis in the 188 Re-bevacizumab group compared with controls and other treatment groups. In vivo, tumor volumes in the 188 Re-bevacizumab (11.1 MBq/mice) group were not reduced but growth was delayed compared with other groups. Thus, 188 Re-bevacizumab enhanced the therapeutic effect of bevacizumab, suggesting a potential therapeutic strategy for NSCLC treatment.

  8. Development of an Inline Urine Monitoring System for the International Space Station

    NASA Technical Reports Server (NTRS)

    Broyan, James Lee, Jr.; Cibuzar, Banelle R.

    2008-01-01

    Human exposure to microgravity during spaceflight causes bone loss. Calcium and other metabolic byproducts are excreted in urine voids. Frequent and accurate measurement of urine void volume and constituents is essential to determining crew bone loss and the effectiveness of countermeasures. Previous US Space Shuttle (SS) Urine Monitoring System (UMS) technology was unable to accurately measure urine void volumes due to cross contamination between users and fluid system instabilities. Currently, urine voids must be collected manually in a flexible plastic bag containing a known tracer quantity. The crew member must completely mix the bag then withdraw a representative syringe sample for later ground analysis. The current bag system accuracy is highly dependent on mixing technique. The International Space Station (ISS) UMS has been developed as an automated device that collects urine from the Waste and Hygiene Compartment (WHC) urinal funnel interface, separates the urine, measures the void volume, and allows for syringe sampling. After operations, the ISS UMS delivers the urine to the WHC for normal processing then flushes its plumbing with a small water volume. The current ISS UMS design incorporates an innovative rotary separator that minimizes foaming, greatly reduces cross contamination between urine voids (< 0.5 ml urine), and provides accurate volume measurements (< +/- 2% error for 100 to 1000 ml void volumes). The system performance has been validated with extensive ground tests and reduced gravity aircraft flights. The lockersized ISS UMS is currently being modified to interface with the ISS Node 3 WHC Russian ACY hardware. The operation principles, characteristics, and results are outlined in the paper.

  9. Deployable Propulsion and Power Systems for Solar System Exploration

    NASA Technical Reports Server (NTRS)

    Johnson, Les; Carr, John

    2017-01-01

    NASA is developing thin-film based, deployable propulsion, power and communication systems for small spacecraft that could provide a revolutionary new capability allowing small spacecraft exploration of the solar system. The Near Earth Asteroid (NEA) Scout reconnaissance mission will demonstrate solar sail propulsion on a 6U CubeSat interplanetary spacecraft and lay the groundwork for their future use in deep space science and exploration missions. Solar sails use sunlight to propel vehicles through space by reflecting solar photons from a large, mirror-like sail made of a lightweight, highly reflective material. This continuous photon pressure provides propellantless thrust, allowing for very high delta V maneuvers on long-duration, deep space exploration. Since reflected light produces thrust, solar sails require no onboard propellant. The Lightweight Integrated Solar Array and Transceiver (LISA-T) is a launch stowed, orbit deployed array on which thin-film photovoltaic and antenna elements are embedded. Inherently, small satellites are limited in surface area, volume, and mass allocation; driving competition between power, communications, and GN&C (guidance navigation and control) subsystems. This restricts payload capability and limits the value of these low-cost satellites. LISA-T is addressing this issue, deploying large-area arrays from a reduced volume and mass envelope - greatly enhancing power generation and communications capabilities of small spacecraft. The NEA Scout mission, funded by NASA's Advanced Exploration Systems Program and managed by NASA MSFC, will use the solar sail as its primary propulsion system, allowing it to survey and image one or more NEA's of interest for possible future human exploration. NEA Scout uses a 6U cubesat (to be provided by NASA's Jet Propulsion Laboratory), an 86 sq m solar sail and will weigh less than 12 kilograms. NEA Scout will be launched on the first flight of the Space Launch System in 2018. Similar in concept to the NEA Scout solar sail, the LISA-T array is designed to fit into a very small volume and provide abundant power and omnidirectional communications in just about any deployment configuration. The technology is being proposed for flight validation as early as 2019 in a low earth orbit demonstration using a 3U cubesat, of which less than 1U will be devoted to the LISA-T power and propulsion system. By leveraging recent advancements in thin films, photovoltaics and miniaturized electronics, new mission-level capabilities will be enabled aboard lower-cost small spacecraft instead of their more expensive, traditional counterparts, enabling a new generation of frequent, inexpensive deep space missions.

  10. Portal Vein Embolization before Right Hepatectomy: Improved Results Using n-Butyl-Cyanoacrylate Compared to Microparticles Plus Coils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guiu, Boris, E-mail: boris.guiu@chu-dijon.fr; Bize, Pierre; Gunthern, Daniel

    Background: There is currently no consensus in the literature on which embolic agent induces the greatest degree of liver hypertrophy after portal vein embolization (PVE). Only experimental results in a pig model have demonstrated an advantage of n-butyl-cyanoacrylate (NBCA) over 3 other embolic materials (hydrophilic gel, small and large polyvinyl alcohol particles) for PVE. Therefore, the aim of this human study was to retrospectively compare the results of PVE using NBCA with those using spherical microparticles plus coils. Methods: A total of 34 patients underwent PVE using either NBCA (n = 20), or spherical microparticles plus coils (n = 14).more » PVE was decided according to preoperative volumetry on the basis of contrast-enhanced CT. Groups were compared for age, sex, volume of the left lobe before PVE and future remnant liver ratio (FRL) (volume of the left lobe/total liver volume - tumor volume). The primary end point was the increase in left lobe volume 1 month after PVE. Secondary end points were procedure complications and biological tolerance. Results: Both groups were similar in terms of age, sex ratio, left lobe volume, and FRL before PVE. NBCA induced a greater increase in volume after PVE than did microparticles plus coils (respectively, +74 {+-} 69 % and +23 {+-} 14 %, p < 0.05). The amount of contrast medium used for the procedure was significantly larger when microparticles and coils rather than NBCA were used (respectively, 264 {+-} 43 ml and 162 {+-} 34 ml, p < 0.01). The rate of PVE complications as well as the biological tolerance was similar in both groups. Conclusion: NBCA seems more effective than spherical microparticles plus coils to induce left-lobe hypertrophy.« less

  11. 40 CFR 1051.625 - What special provisions apply to unique snowmobile designs for small-volume manufacturers?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false What special provisions apply to unique snowmobile designs for small-volume manufacturers? 1051.625 Section 1051.625 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM RECREATIONAL ENGINES AND VEHICLES Compliance...

  12. Magnetic resonance imaging for precise radiotherapy of small laboratory animals.

    PubMed

    Frenzel, Thorsten; Kaul, Michael Gerhard; Ernst, Thomas Michael; Salamon, Johannes; Jäckel, Maria; Schumacher, Udo; Krüll, Andreas

    2017-03-01

    Radiotherapy of small laboratory animals (SLA) is often not as precisely applied as in humans. Here we describe the use of a dedicated SLA magnetic resonance imaging (MRI) scanner for precise tumor volumetry, radiotherapy treatment planning, and diagnostic imaging in order to make the experiments more accurate. Different human cancer cells were injected at the lower trunk of pfp/rag2 and SCID mice to allow for local tumor growth. Data from cross sectional MRI scans were transferred to a clinical treatment planning system (TPS) for humans. Manual palpation of the tumor size was compared with calculated tumor size of the TPS and with tumor weight at necropsy. As a feasibility study MRI based treatment plans were calculated for a clinical 6MV linear accelerator using a micro multileaf collimator (μMLC). In addition, diagnostic MRI scans were used to investigate animals which did clinical poorly during the study. MRI is superior in precise tumor volume definition whereas manual palpation underestimates their size. Cross sectional MRI allow for treatment planning so that conformal irradiation of mice with a clinical linear accelerator using a μMLC is in principle feasible. Several internal pathologies were detected during the experiment using the dedicated scanner. MRI is a key technology for precise radiotherapy of SLA. The scanning protocols provided are suited for tumor volumetry, treatment planning, and diagnostic imaging. Copyright © 2016. Published by Elsevier GmbH.

  13. A computer system for analysis and transmission of spirometry waveforms using volume sampling.

    PubMed

    Ostler, D V; Gardner, R M; Crapo, R O

    1984-06-01

    A microprocessor-controlled data gathering system for telemetry and analysis of spirometry waveforms was implemented using a completely digital design. Spirometry waveforms were obtained from an optical shaft encoder attached to a rolling seal spirometer. Time intervals between 10-ml volume changes (volume sampling) were stored. The digital design eliminated problems of analog signal sampling. The system measured flows up to 12 liters/sec with 5% accuracy and volumes up to 10 liters with 1% accuracy. Transmission of 10 waveforms took about 3 min. Error detection assured that no data were lost or distorted during transmission. A pulmonary physician at the central hospital reviewed the volume-time and flow-volume waveforms and interpretations generated by the central computer before forwarding the results and consulting with the rural physician. This system is suitable for use in a major hospital, rural hospital, or small clinic because of the system's simplicity and small size.

  14. Embryonic cardiac morphometry in Carnegie stages 15-23, from the Complutense University of Madrid Institute of Embryology Human Embryo Collection.

    PubMed

    Arráez-Aybar, L A; Turrero-Nogués, A; Marantos-Gamarra, D G

    2008-01-01

    We performed a morphometric study of cardiac development on human embryos to complement the scarce data on human embryonic cardiac morphometry and to attempt to establish, from these, algorithms describing cardiac growth during the second month of gestation. Thirty human embryos from Carnegie stages 15-23 were included in the study. Shrinkage and compression effects from fixation and inclusion in paraffin were considered in our calculations. Growth of the cardiac (whole heart) volume and volume of ventricular myocardium through the Carnegie stages were analysed by ANOVA. Linear correlation was used to describe the relationship between the ventricular myocardium and cardiac volumes. Comparisons of models were carried out through the R2 statistic. The relationship volume of ventricular myocardium versus cardiac volume is expressed by the equation: cardiac volume = 0.6266 + 2.4778 volume of ventricular myocardium. The relationship cardiac volume versus crown-rump length is expressed by the equation: cardiac volume = 1.3 e(0.126 CR length), where e is the base of natural logarithms. At a clinical level, these results can contribute towards the establishment of a normogram for cardiac development, useful for the design of strategies for early diagnosis of congenital heart disease. They can also help in the study of embryogenesis, for example in the discussion of ventricular trabeculation. Copyright 2007 S. Karger AG, Basel.

  15. Spaceflight Human System Standards

    NASA Technical Reports Server (NTRS)

    Holubec, Keith; Tillman, Barry; Connolly, Jan

    2009-01-01

    NASA created a new approach for human system integration and human performance standards. NASA created two documents a standard and a reference handbook. The standard is titled NASA Space Flight Human-System Standard (SFHSS) and consists of two-volumes: Volume 1- Crew Health This volume covers standards needed to support astronaut health (medical care, nutrition, sleep, exercise, etc.) Volume 2 Human Factors, Habitability and Environmental Health This volume covers the standards for system design that will maintain astronaut performance (ie., environmental factors, design of facilities, layout of workstations, and lighting requirements). It includes classic human factors requirements. The new standards document is written in terms so that it is applicable to a broad range of present and future NASA systems. The document states that all new programs prepare system-specific requirements that will meet the general standards. For example, the new standard does not specify a design should accommodate specific percentiles of a defined population. Rather, NASA-STD-3001, Volume 2 states that all programs shall prepare program-specific requirements that define the user population and their size ranges. The design shall then accommodate the full size range of those users. The companion reference handbook, Human Integration Design Handbook (HIDH), was developed to capture the design consideration information from NASA-STD-3000, and adds spaceflight lessons learned, gaps in knowledge, example solutions, and suggests research to further mature specific disciplines. The HIDH serves two major purposes: HIDH is the reference document for writing human factors requirements for specific systems. HIDH contains design guidance information that helps insure that designers create systems which safely and effectively accommodate the capabilities and limitations of space flight crews.

  16. Assessment of growth dynamics of human cranium middle fossa in foetal period.

    PubMed

    Skomra, Andrzej; Kędzia, Alicja; Dudek, Krzysztof; Bogacz, Wiesław

    2014-01-01

    Available literature analysis demonstrated smallness of studies of cranial base. The goal of the study was to analyse the medial fossa of the human cranium in the foetal period against other fossae. Survey material consisted of 110 human foetuses at a morphological age of 16-28 weeks of foetal life, CRL 98-220 mm. Anthropological, preparation method, reverse method and statistical analysis were utilized. The survey incorporated the following computer programmes: Renishaw, TraceSurf, AutoCAD, CATIA. The reverse method seems especially interesting (impression with polysiloxane (silicone elastomer of high adhesive power used in dentistry) with 18 D 4823 activator. Elicited impression accurately reflected complex shape of cranium base. On assessing the relative rate of cranium medial fossa, the rate was found to be stable (linear model) for the whole of the analysed period and is 0.19%/week, which stands for the gradual and steady growth of the middle fossa in relation to the whole of the cranium base. At the same time, from the 16th till 28th week of foetal life, relative volume of the cranium middle fossa increases more intensively than cranium anterior fossa, whereas the cranium middle fossa volume as compared with the cranium posterior fossa is definitely slower. In the analysed period, the growth rate of the cranium base middle fossa was bigger in the 4th and 5th weeks than in the 6th and 7th weeks of foetal life. The investigations revealed cranium base asymmetry of the left side. Furthermore, the anterior fossae volume on the left side is significantly bigger than the one of the fossae on the right side. Volume growth rate is more intensive in the 4th and 5th than in the 6th and 7th weeks of foetal life. In the examined period, the relative growth rate of cranium base middle fossa is 0.19%/week and it is stable - linear model. The study revealed correlations in the form of mathematical models, which enabled foetuses age assessment.

  17. Detector to detector corrections: a comprehensive experimental study of detector specific correction factors for beam output measurements for small radiotherapy beams.

    PubMed

    Azangwe, Godfrey; Grochowska, Paulina; Georg, Dietmar; Izewska, Joanna; Hopfgartner, Johannes; Lechner, Wolfgang; Andersen, Claus E; Beierholm, Anders R; Helt-Hansen, Jakob; Mizuno, Hideyuki; Fukumura, Akifumi; Yajima, Kaori; Gouldstone, Clare; Sharpe, Peter; Meghzifene, Ahmed; Palmans, Hugo

    2014-07-01

    The aim of the present study is to provide a comprehensive set of detector specific correction factors for beam output measurements for small beams, for a wide range of real time and passive detectors. The detector specific correction factors determined in this study may be potentially useful as a reference data set for small beam dosimetry measurements. Dose response of passive and real time detectors was investigated for small field sizes shaped with a micromultileaf collimator ranging from 0.6 × 0.6 cm(2) to 4.2 × 4.2 cm(2) and the measurements were extended to larger fields of up to 10 × 10 cm(2). Measurements were performed at 5 cm depth, in a 6 MV photon beam. Detectors used included alanine, thermoluminescent dosimeters (TLDs), stereotactic diode, electron diode, photon diode, radiophotoluminescent dosimeters (RPLDs), radioluminescence detector based on carbon-doped aluminium oxide (Al2O3:C), organic plastic scintillators, diamond detectors, liquid filled ion chamber, and a range of small volume air filled ionization chambers (volumes ranging from 0.002 cm(3) to 0.3 cm(3)). All detector measurements were corrected for volume averaging effect and compared with dose ratios determined from alanine to derive a detector correction factors that account for beam perturbation related to nonwater equivalence of the detector materials. For the detectors used in this study, volume averaging corrections ranged from unity for the smallest detectors such as the diodes, 1.148 for the 0.14 cm(3) air filled ionization chamber and were as high as 1.924 for the 0.3 cm(3) ionization chamber. After applying volume averaging corrections, the detector readings were consistent among themselves and with alanine measurements for several small detectors but they differed for larger detectors, in particular for some small ionization chambers with volumes larger than 0.1 cm(3). The results demonstrate how important it is for the appropriate corrections to be applied to give consistent and accurate measurements for a range of detectors in small beam geometry. The results further demonstrate that depending on the choice of detectors, there is a potential for large errors when effects such as volume averaging, perturbation and differences in material properties of detectors are not taken into account. As the commissioning of small fields for clinical treatment has to rely on accurate dose measurements, the authors recommend the use of detectors that require relatively little correction, such as unshielded diodes, diamond detectors or microchambers, and solid state detectors such as alanine, TLD, Al2O3:C, or scintillators.

  18. A mouse anti-myostatin antibody increases muscle mass and improves muscle strength and contractility in the mdx mouse model of Duchenne muscular dystrophy and its humanized equivalent, domagrozumab (PF-06252616), increases muscle volume in cynomolgus monkeys.

    PubMed

    St Andre, Michael; Johnson, Mark; Bansal, Prashant N; Wellen, Jeremy; Robertson, Andrew; Opsahl, Alan; Burch, Peter M; Bialek, Peter; Morris, Carl; Owens, Jane

    2017-11-09

    The treatments currently approved for Duchenne muscular dystrophy (DMD), a progressive skeletal muscle wasting disease, address the needs of only a small proportion of patients resulting in an urgent need for therapies that benefit all patients regardless of the underlying mutation. Myostatin is a member of the transforming growth factor-β (TGF-β) family of ligands and is a negative regulator of skeletal muscle mass. Loss of myostatin has been shown to increase muscle mass and improve muscle function in both normal and dystrophic mice. Therefore, myostatin blockade via a specific antibody could ameliorate the muscle weakness in DMD patients by increasing skeletal muscle mass and function, thereby reducing patients' functional decline. A murine anti-myostatin antibody, mRK35, and its humanized analog, domagrozumab, were developed and their ability to inhibit several TGB-β ligands was measured using a cell-based Smad-activity reporter system. Normal and mdx mice were treated with mRK35 to examine the antibody's effect on body weight, lean mass, muscle weights, grip strength, ex vivo force production, and fiber size. The humanized analog (domagrozumab) was tested in non-human primates (NHPs) for changes in skeletal muscle mass and volume as well as target engagement via modulation of circulating myostatin. Both the murine and human antibodies are specific and potent inhibitors of myostatin and GDF11. mRK35 is able to increase body weight, lean mass, and muscle weights in normal mice. In mdx mice, mRK35 significantly increased body weight, muscle weights, grip strength, and ex vivo force production in the extensor digitorum longus (EDL) muscle. Further, tibialis anterior (TA) fiber size was significantly increased. NHPs treated with domagrozumab demonstrated a dose-dependent increase in lean mass and muscle volume and exhibited increased circulating levels of myostatin demonstrating target engagement. We demonstrated that the potent anti-myostatin antibody mRK35 and its clinical analog, domagrozumab, were able to induce muscle anabolic activity in both rodents, including the mdx mouse model of DMD, and non-human primates. A Phase 2, potentially registrational, clinical study with domagrozumab in DMD patients is currently underway.

  19. Genetic variations in the serotonergic system contribute to amygdala volume in humans

    PubMed Central

    Li, Jin; Chen, Chunhui; Wu, Karen; Zhang, Mingxia; Zhu, Bi; Chen, Chuansheng; Moyzis, Robert K.; Dong, Qi

    2015-01-01

    The amygdala plays a critical role in emotion processing and psychiatric disorders associated with emotion dysfunction. Accumulating evidence suggests that amygdala structure is modulated by serotonin-related genes. However, there is a gap between the small contributions of single loci (less than 1%) and the reported 63–65% heritability of amygdala structure. To understand the “missing heritability,” we systematically explored the contribution of serotonin genes on amygdala structure at the gene set level. The present study of 417 healthy Chinese volunteers examined 129 representative polymorphisms in genes from multiple biological mechanisms in the regulation of serotonin neurotransmission. A system-level approach using multiple regression analyses identified that nine SNPs collectively accounted for approximately 8% of the variance in amygdala volume. Permutation analyses showed that the probability of obtaining these findings by chance was low (p = 0.043, permuted for 1000 times). Findings showed that serotonin genes contribute moderately to individual differences in amygdala volume in a healthy Chinese sample. These results indicate that the system-level approach can help us to understand the genetic basis of a complex trait such as amygdala structure. PMID:26500508

  20. Sustained hyperhydration with glycerol ingestion.

    PubMed

    Koenigsberg, P S; Martin, K K; Hlava, H R; Riedesel, M L

    1995-01-01

    Heavy exercise lasting more than three hours tends to result in dehydration, as the fluid intake is less than fluid loss by sweat and urine. Dehydration as small as one percent of body weight has been reported to decrease work capacity. In present and previous studies insensible water loss and sweat are assumed to be the same in both control and experimental conditions. Fluid intake less urine volume is utilized as an indicator of euhydration, hypohydration, or hyperhydration. Previous studies involving glycerol intake describe hyperhydration for 4.5 to 8 hours. The objective of this study was to keep subjects hyperhydrated (retention of water) for 32 or 49 hours. The experimental protocol involved ingestion of a large volume of fluid (39.2 or 51.1 ml/kg/d) with glycerol (2.9 to 3.1 g/kg/d) and without glycerol. In both Series I (49 h) and Series II (32 h) experiments, the intake of glycerol resulted in smaller urine volumes. This study demonstrates it is possible to keep human subjects hyperhydrated for extended periods of time and thereby reduce the amount of fluid consumption necessary just prior to or during bouts of negative fluid balance situations.

  1. Aerial Vehicles to Detect Maximum Volume of Plume Material Associated with Habitable Areas in Extreme Environments

    NASA Technical Reports Server (NTRS)

    Gunasekara, Onalli; Wong, Uland Y.; Furlong, Michael P.; Dille, Michael

    2017-01-01

    Current technologies of exploring habitable areas of icy moons are limited to flybys of space probes. This research project addresses long-term navigation of icy moons by developing a MATLAB adjustable trajectory based on the volume of plume material observed. Plumes expose materials from the sub-surface without accessing the subsurface. Aerial vehicles capable of scouting vapor plumes and detecting maximum plume material volumes, which are considered potentially habitable in inhospitable environments, would enable future deep-space missions to search for extraterrestrial organisms on the surface of icy moons. Although this platform is still a prototype, it demonstrates the potential aerial vehicles can have in improving the capabilities of long-term space navigation and enabling technology for detecting life in extreme environments. Additionally, this work is developing the capabilities that could be utilized as a platform for space biology research. For example, aerial vehicles that are sent to map extreme environments of icy moons or the planet Mars, could also carry small payloads with automated cell-biology experiments, designed to probe the biological response of low-gravity and high-radiation planetary environments, serving as a pathfinder for future human missions.

  2. Maternal sensitivity, infant limbic structure volume and functional connectivity: a preliminary study

    PubMed Central

    Rifkin-Graboi, A; Kong, L; Sim, L W; Sanmugam, S; Broekman, B F P; Chen, H; Wong, E; Kwek, K; Saw, S-M; Chong, Y-S; Gluckman, P D; Fortier, M V; Pederson, D; Meaney, M J; Qiu, A

    2015-01-01

    Mechanisms underlying the profound parental effects on cognitive, emotional and social development in humans remain poorly understood. Studies with nonhuman models suggest variations in parental care affect the limbic system, influential to learning, autobiography and emotional regulation. In some research, nonoptimal care relates to decreases in neurogenesis, although other work suggests early-postnatal social adversity accelerates the maturation of limbic structures associated with emotional learning. We explored whether maternal sensitivity predicts human limbic system development and functional connectivity patterns in a small sample of human infants. When infants were 6 months of age, 20 mother–infant dyads attended a laboratory-based observational session and the infants underwent neuroimaging at the same age. After considering age at imaging, household income and postnatal maternal anxiety, regression analyses demonstrated significant indirect associations between maternal sensitivity and bilateral hippocampal volume at six months, with the majority of associations between sensitivity and the amygdala demonstrating similar indirect, but not significant results. Moreover, functional analyses revealed direct associations between maternal sensitivity and connectivity between the hippocampus and areas important for emotional regulation and socio-emotional functioning. Sensitivity additionally predicted indirect associations between limbic structures and regions related to autobiographical memory. Our volumetric results are consistent with research indicating accelerated limbic development in response to early social adversity, and in combination with our functional results, if replicated in a larger sample, may suggest that subtle, but important, variations in maternal care influence neuroanatomical trajectories important to future cognitive and emotional functioning. PMID:26506054

  3. Modified Technique For Chemisorption Measurements

    NASA Technical Reports Server (NTRS)

    Schryer, David R.; Brown, Kenneth G.; Schryer, Jacqueline

    1989-01-01

    In measurements of chemisorption of CO on Pt/SnO2 catalyst observed that if small numbers of relatively large volumes of adsorbate gas are passed through sample, very little removal of CO detected. In these cases little or no CO has been chemisorbed on Pt/SnO2. Technique of using large number of small volumes of adsorbate gas to measure chemisorption applicable to many gas/material combinations other than CO on Pt/SnO2. Volume used chosen so that at least 10 percent of adsorbate gas removed during each exposure.

  4. Allometric Analysis Detects Brain Size-Independent Effects of Sex and Sex Chromosome Complement on Human Cerebellar Organization

    PubMed Central

    Mankiw, Catherine; Park, Min Tae M.; Reardon, P.K.; Fish, Ari M.; Clasen, Liv S.; Greenstein, Deanna; Blumenthal, Jonathan D.; Lerch, Jason P.; Chakravarty, M. Mallar

    2017-01-01

    The cerebellum is a large hindbrain structure that is increasingly recognized for its contribution to diverse domains of cognitive and affective processing in human health and disease. Although several of these domains are sex biased, our fundamental understanding of cerebellar sex differences—including their spatial distribution, potential biological determinants, and independence from brain volume variation—lags far behind that for the cerebrum. Here, we harness automated neuroimaging methods for cerebellar morphometrics in 417 individuals to (1) localize normative male–female differences in raw cerebellar volume, (2) compare these to sex chromosome effects estimated across five rare sex (X/Y) chromosome aneuploidy (SCA) syndromes, and (3) clarify brain size-independent effects of sex and SCA on cerebellar anatomy using a generalizable allometric approach that considers scaling relationships between regional cerebellar volume and brain volume in health. The integration of these approaches shows that (1) sex and SCA effects on raw cerebellar volume are large and distributed, but regionally heterogeneous, (2) human cerebellar volume scales with brain volume in a highly nonlinear and regionally heterogeneous fashion that departs from documented patterns of cerebellar scaling in phylogeny, and (3) cerebellar organization is modified in a brain size-independent manner by sex (relative expansion of total cerebellum, flocculus, and Crus II-lobule VIIIB volumes in males) and SCA (contraction of total cerebellar, lobule IV, and Crus I volumes with additional X- or Y-chromosomes; X-specific contraction of Crus II-lobule VIIIB). Our methods and results clarify the shifts in human cerebellar organization that accompany interwoven variations in sex, sex chromosome complement, and brain size. SIGNIFICANCE STATEMENT Cerebellar systems are implicated in diverse domains of sex-biased behavior and pathology, but we lack a basic understanding of how sex differences in the human cerebellum are distributed and determined. We leverage a rare neuroimaging dataset to deconvolve the interwoven effects of sex, sex chromosome complement, and brain size on human cerebellar organization. We reveal topographically variegated scaling relationships between regional cerebellar volume and brain size in humans, which (1) are distinct from those observed in phylogeny, (2) invalidate a traditional neuroimaging method for brain volume correction, and (3) allow more valid and accurate resolution of which cerebellar subcomponents are sensitive to sex and sex chromosome complement. These findings advance understanding of cerebellar organization in health and sex chromosome aneuploidy. PMID:28314818

  5. Stochastic theory of large-scale enzyme-reaction networks: Finite copy number corrections to rate equation models

    NASA Astrophysics Data System (ADS)

    Thomas, Philipp; Straube, Arthur V.; Grima, Ramon

    2010-11-01

    Chemical reactions inside cells occur in compartment volumes in the range of atto- to femtoliters. Physiological concentrations realized in such small volumes imply low copy numbers of interacting molecules with the consequence of considerable fluctuations in the concentrations. In contrast, rate equation models are based on the implicit assumption of infinitely large numbers of interacting molecules, or equivalently, that reactions occur in infinite volumes at constant macroscopic concentrations. In this article we compute the finite-volume corrections (or equivalently the finite copy number corrections) to the solutions of the rate equations for chemical reaction networks composed of arbitrarily large numbers of enzyme-catalyzed reactions which are confined inside a small subcellular compartment. This is achieved by applying a mesoscopic version of the quasisteady-state assumption to the exact Fokker-Planck equation associated with the Poisson representation of the chemical master equation. The procedure yields impressively simple and compact expressions for the finite-volume corrections. We prove that the predictions of the rate equations will always underestimate the actual steady-state substrate concentrations for an enzyme-reaction network confined in a small volume. In particular we show that the finite-volume corrections increase with decreasing subcellular volume, decreasing Michaelis-Menten constants, and increasing enzyme saturation. The magnitude of the corrections depends sensitively on the topology of the network. The predictions of the theory are shown to be in excellent agreement with stochastic simulations for two types of networks typically associated with protein methylation and metabolism.

  6. Volume of the human septal forebrain region is a predictor of source memory accuracy.

    PubMed

    Butler, Tracy; Blackmon, Karen; Zaborszky, Laszlo; Wang, Xiuyuan; DuBois, Jonathan; Carlson, Chad; Barr, William B; French, Jacqueline; Devinsky, Orrin; Kuzniecky, Ruben; Halgren, Eric; Thesen, Thomas

    2012-01-01

    Septal nuclei, components of basal forebrain, are strongly and reciprocally connected with hippocampus, and have been shown in animals to play a critical role in memory. In humans, the septal forebrain has received little attention. To examine the role of human septal forebrain in memory, we acquired high-resolution magnetic resonance imaging scans from 25 healthy subjects and calculated septal forebrain volume using recently developed probabilistic cytoarchitectonic maps. We indexed memory with the California Verbal Learning Test-II. Linear regression showed that bilateral septal forebrain volume was a significant positive predictor of recognition memory accuracy. More specifically, larger septal forebrain volume was associated with the ability to recall item source/context accuracy. Results indicate specific involvement of septal forebrain in human source memory, and recall the need for additional research into the role of septal nuclei in memory and other impairments associated with human diseases.

  7. Milk osmolality: does it matter?

    PubMed

    Pearson, Freya; Johnson, Mark J; Leaf, Alison A

    2013-03-01

    High osmolality of infant feed reflects a high concentration of solute particles and has been implicated as a cause of necrotising enterocolitis. Evidence for direct intestinal mucosal injury as a result of hyperosmolar feeds is scant, and no good evidence has been found to support such an association. High osmolality of enteral substrate may, however, slow down gastric emptying. Osmolality of current infant feeds ranges from around 300 mOsm/kg in human breast milk to just more than 400 mOsm/kg in fully fortified breast milk. Addition of mineral and vitamin supplements to small volumes of milk can increase osmolality significantly and should be avoided if possible.

  8. Cardiovascular responses to spaceflight

    NASA Technical Reports Server (NTRS)

    Nicogossian, A.; Pool, S. L.; Rambaut, P. C.

    1983-01-01

    The cardiovascular system's adaptive changes during and after spaceflight are discussed. Cephalic fluid shifts are demonstrated by photographs along with calf girth and leg volume changes. Inflight measurements show an increase in average resting heart rate and systolic blood pressure, and a sympathetic-parasympathetic neural imbalance. Postflight findings include a small but reversible decrease in the left ventricular muscle mass. Since 1980, NASA's research has emphasized cardiovascular deconditioning and countermeasures: hemodynamic changes, endocrine and neurohumoral aspects, etiologic factors, and lower body negative pressure devices. Though human beings acclimate to the space environment, questions concerning the immediate and long-term aspects of spaceflight need to be answered for adequate planning of extended space missions.

  9. Handheld Universal Diagnostic Sensor

    NASA Technical Reports Server (NTRS)

    Chan, Eugene

    2012-01-01

    The rHEALTH technology is designed to shrink an entire hospital testing laboratory onto a handheld device. A physician or healthcare provider performs the test by collecting a fingerstick of blood from a patient. The tiny volume of blood is inserted into the rHEALTH device. Inside the device is a microfluidic chip that contains small channels about the width of a human hair. These channels help move the blood and analyze the blood sample. The rHEALTH sensor uses proprietary reagents called nanostrips, which are nanoscale test strips that enable the clinical assays. The readout is performed by laser-induced fluorescence. Overall, the time from blood collection through analysis is less than a minute.

  10. Availability and temporal heterogeneity of water supply affect the vertical distribution and mortality of a belowground herbivore and consequently plant growth.

    PubMed

    Tsunoda, Tomonori; Kachi, Naoki; Suzuki, Jun-Ichirou

    2014-01-01

    We examined how the volume and temporal heterogeneity of water supply changed the vertical distribution and mortality of a belowground herbivore, and consequently affected plant biomass. Plantago lanceolata (Plantaginaceae) seedlings were grown at one per pot under different combinations of water volume (large or small volume) and heterogeneity (homogeneous water conditions, watered every day; heterogeneous conditions, watered every 4 days) in the presence or absence of a larva of the belowground herbivorous insect, Anomala cuprea (Coleoptera: Scarabaeidae). The larva was confined in different vertical distributions to top feeding zone (top treatment), middle feeding zone (middle treatment), or bottom feeding zone (bottom treatment); alternatively no larva was introduced (control treatment) or larval movement was not confined (free treatment). Three-way interaction between water volume, heterogeneity, and the herbivore significantly affected plant biomass. With a large water volume, plant biomass was lower in free treatment than in control treatment regardless of heterogeneity. Plant biomass in free treatment was as low as in top treatment. With a small water volume and in free treatment, plant biomass was low (similar to that under top treatment) under homogeneous water conditions but high under heterogeneous ones (similar to that under middle or bottom treatment). Therefore, there was little effect of belowground herbivory on plant growth under heterogeneous water conditions. In other watering regimes, herbivores would be distributed in the shallow soil and reduced root biomass. Herbivore mortality was high with homogeneous application of a large volume or heterogeneous application of a small water volume. Under the large water volume, plant biomass was high in pots in which the herbivore had died. Thus, the combinations of water volume and heterogeneity affected plant growth via the change of a belowground herbivore.

  11. Magnetic Resonance Imaging Profile of Blood–Brain Barrier Injury in Patients With Acute Intracerebral Hemorrhage

    PubMed Central

    Aksoy, Didem; Bammer, Roland; Mlynash, Michael; Venkatasubramanian, Chitra; Eyngorn, Irina; Snider, Ryan W.; Gupta, Sandeep N.; Narayana, Rashmi; Fischbein, Nancy; Wijman, Christine A. C.

    2013-01-01

    Background Spontaneous intracerebral hemorrhage (ICH) is associated with blood–brain barrier (BBB) injury, which is a poorly understood factor in ICH pathogenesis, potentially contributing to edema formation and perihematomal tissue injury. We aimed to assess and quantify BBB permeability following human spontaneous ICH using dynamic contrast‐enhanced magnetic resonance imaging (DCE MRI). We also investigated whether hematoma size or location affected the amount of BBB leakage. Methods and Results Twenty‐five prospectively enrolled patients from the Diagnostic Accuracy of MRI in Spontaneous intracerebral Hemorrhage (DASH) study were examined using DCE MRI at 1 week after symptom onset. Contrast agent dynamics in the brain tissue and general tracer kinetic modeling were used to estimate the forward leakage rate (Ktrans) in regions of interest (ROI) in and surrounding the hematoma and in contralateral mirror–image locations (control ROI). In all patients BBB permeability was significantly increased in the brain tissue immediately adjacent to the hematoma, that is, the hematoma rim, compared to the contralateral mirror ROI (P<0.0001). Large hematomas (>30 mL) had higher Ktrans values than small hematomas (P<0.005). Ktrans values of lobar hemorrhages were significantly higher than the Ktrans values of deep hemorrhages (P<0.005), independent of hematoma volume. Higher Ktrans values were associated with larger edema volumes. Conclusions BBB leakage in the brain tissue immediately bordering the hematoma can be measured and quantified by DCE MRI in human ICH. BBB leakage at 1 week is greater in larger hematomas as well as in hematomas in lobar locations and is associated with larger edema volumes. PMID:23709564

  12. Phenomenological Partial Specific Volumes for G-Quadruplex DNAs

    PubMed Central

    Hellman, Lance M.; Rodgers, David W.; Fried, Michael G.

    2009-01-01

    Accurate partial specific volume (ν̄) values are required for sedimentation velocity and sedimentation equilibrium analyses. For nucleic acids, the estimation of these values is complicated by the fact that ν̄ depends on base composition, secondary structure, solvation and the concentrations and identities of ions in the surrounding buffer. Here we describe sedimentation equilibrium measurements of the apparent isopotential partial specific volume φ′ for two G-quadruplex DNAs and a single-stranded DNA of similar molecular weight and base composition. The G-quadruplex DNAs are a 22 nucleotide fragment of the human telomere consensus sequence and a 27 nucleotide fragment from the human c-myc promoter. The single-stranded DNA is 26 nucleotides long and is designed to have low propensity to form secondary structures. Parallel measurements were made in buffers containing NaCl and in buffers containing KCl, spanning the range 0.09M ≤ [salt] ≤ 2.3M. Limiting values of φ′, extrapolated to [salt] = 0M, were: 22-mer (NaCl-form), 0.525 ± 0.004 mL/g; 22-mer (KCl-form), 0.531 ± 0.006 mL/g; 27-mer (NaCl-form), 0.548 ± 0.005 mL/g; 27-mer (KCl-form), 0.557 ± 0.006 mL/g; 26-mer (NaCl-form), 0.555 ± 0.004 mL/g; 26-mer (KCl-form), 0.564 ± 0.006 mL/g. Small changes in φ′ with [salt] suggest that large changes in counterion association or hydration are unlikely to take place over these concentration ranges. PMID:19238377

  13. Optimization and Dose Estimation of Aerosol Delivery to Non-Human Primates.

    PubMed

    MacLoughlin, Ronan J; van Amerongen, Geert; Fink, James B; Janssens, Hettie M; Duprex, W Paul; de Swart, Rik L

    2016-06-01

    In pre-clinical animal studies, the uniformity of dosing across subjects and routes of administration is a crucial requirement. In preparation for a study in which aerosolized live-attenuated measles virus vaccine was administered to cynomolgus monkeys (Macaca fascicularis) by inhalation, we assessed the percentage of a nebulized dose inhaled under varying conditions. Drug delivery varies with breathing parameters. Therefore we determined macaque breathing patterns (tidal volume, breathing frequency, and inspiratory to expiratory (I:E) ratio) across a range of 3.3-6.5 kg body weight, using a pediatric pneumotachometer interfaced either with an endotracheal tube or a facemask. Subsequently, these breathing patterns were reproduced using a breathing simulator attached to a filter to collect the inhaled dose. Albuterol was nebulized using a vibrating mesh nebulizer and the percentage inhaled dose was determined by extraction of drug from the filter and subsequent quantification. Tidal volumes ranged from 24 to 46 mL, breathing frequencies from 19 to 31 breaths per minute and I:E ratios from 0.7 to 1.6. A small pediatric resuscitation mask was identified as the best fitting interface between animal and pneumotachometer. The average efficiency of inhaled dose delivery was 32.1% (standard deviation 7.5, range 24%-48%), with variation in tidal volumes as the most important determinant. Studies in non-human primates aimed at comparing aerosol delivery with other routes of administration should take both the inter-subject variation and relatively low efficiency of delivery to these low body weight mammals into account.

  14. Clinical investigation of the protective effects of palm vitamin E tocotrienols on brain white matter.

    PubMed

    Gopalan, Yogheswaran; Shuaib, Ibrahim Lutfi; Magosso, Enrico; Ansari, Mukhtar Alam; Abu Bakar, Mohd Rizal; Wong, Jia Woei; Khan, Nurzalina Abdul Karim; Liong, Wei Chuen; Sundram, Kalyana; Ng, Bee Hong; Karuthan, Chinna; Yuen, Kah Hay

    2014-05-01

    Previous cell-based and animal studies showed mixed tocotrienols are neuroprotective, but the effect is yet to be proven in humans. Thus, the present study aimed to evaluate the protective activity of mixed tocotrienols in humans with white matter lesions (WMLs). WMLs are regarded as manifestations of cerebral small vessel disease, reflecting varying degrees of neurodegeneration and tissue damage with potential as a surrogate end point in clinical trials. A total of 121 volunteers aged ≥35 years with cardiovascular risk factors and MRI-confirmed WMLs were randomized to receive 200 mg mixed tocotrienols or placebo twice a day for 2 years. The WML volumes were measured from MRI images taken at baseline, 1 year, and 2 years using a validated software and were compared. Fasting blood samples were collected for full blood chemistry investigation. According to per-protocol (88 volunteers) and intention-to-treat (121 volunteers) analyses, the mean WML volume of the placebo group increased after 2 years, whereas that of the tocotrienol-supplemented group remained essentially unchanged. The mean WML volume change between the 2 groups was not significantly different (P=0.150) at the end of 1 year but was significant at the end of 2 years for both per-protocol and intention-to-treat analyses (P=0.019 and P=0.018). No significant difference was observed in the blood chemistry parameters between the 2 groups. Mixed tocotrienols were found to attenuate the progression of WMLs. http://www.clinicaltrials.gov. Unique identifier: NCT00753532.

  15. No relative expansion of the number of prefrontal neurons in primate and human evolution.

    PubMed

    Gabi, Mariana; Neves, Kleber; Masseron, Carolinne; Ribeiro, Pedro F M; Ventura-Antunes, Lissa; Torres, Laila; Mota, Bruno; Kaas, Jon H; Herculano-Houzel, Suzana

    2016-08-23

    Human evolution is widely thought to have involved a particular expansion of prefrontal cortex. This popular notion has recently been challenged, although controversies remain. Here we show that the prefrontal region of both human and nonhuman primates holds about 8% of cortical neurons, with no clear difference across humans and other primates in the distribution of cortical neurons or white matter cells along the anteroposterior axis. Further, we find that the volumes of human prefrontal gray and white matter match the expected volumes for the number of neurons in the gray matter and for the number of other cells in the white matter compared with other primate species. These results indicate that prefrontal cortical expansion in human evolution happened along the same allometric trajectory as for other primate species, without modification of the distribution of neurons across its surface or of the volume of the underlying white matter. We thus propose that the most distinctive feature of the human prefrontal cortex is its absolute number of neurons, not its relative volume.

  16. The Spirit That Moves Us: A Literature-Based Resource Guide. Teaching about Diversity, Prejudice, the Holocaust, and Human Rights. Volume 1: Grades K-4. Revised [and] The Spirit That Moves Us: A Literature-Based Resource Guide. Teaching about the Holocaust and Human Rights. Volume 2: Grades 5-8.

    ERIC Educational Resources Information Center

    Petovello, Laura R.; Quenk, Rachel

    This two-volume resource guide includes lesson plans and bibliographical references for teaching about the Holocaust. The first volume, revised in 1999, covers grades K-4, and the second volume, published in 1997, covers grades 5-8. Each guide offers age-appropriate strategies and lesson plans for teaching students about the fundamental causes of…

  17. Small Business Management. Addendum to Small Business Management Education Curriculum Volume III.

    ERIC Educational Resources Information Center

    Minnesota Univ., St. Paul. Dept. of Agricultural Education.

    A supplement to a previous volume (CE 009 649), this document contains handouts, case problems, schedules, and seminar information keyed to specific units of instruction. The contents by year and unit areas are as follow: year I, unit 1--time management (two-page handout concerning four problems to avoid; year I, unit 2--warranty register (a…

  18. A Simple Theory to Predict Small Changes in Volume and Refractivity During Mixing of a Two-Component Liquid System.

    ERIC Educational Resources Information Center

    Aminabhavi, Tejraj M.

    1983-01-01

    Discusses a set of relations (addressing changes in volume and refractivity) for use in the study of binary systems. Suggests including such an experiment in undergraduate physical chemistry courses (measuring density/refractive index of pure compounds and their mixtures) to predict even small changes occurring during mixing process. (Author/JN)

  19. A semi-automated multiplex high-throughput assay for measuring IgG antibodies against Plasmodium falciparum erythrocyte membrane protein 1 (PfEMP1) domains in small volumes of plasma.

    PubMed

    Cham, Gerald K K; Kurtis, Jonathan; Lusingu, John; Theander, Thor G; Jensen, Anja T R; Turner, Louise

    2008-06-12

    The level of antibodies against PfEMP1 is routinely quantified by the conventional microtitre enzyme-linked immunosorbent assay (ELISA). However, ELISA only measures one analyte at a time and requires a relatively large plasma volume if the complete antibody profile of the sample is to be obtained. Furthermore, assay-to-assay variation and the problem of storage of antigen can influence ELISA results. The bead-based assay described here uses the BioPlex100 (BioRad, Hercules, CA, USA) system which can quantify multiple antibodies simultaneously in a small plasma volume. A total of twenty nine PfEMP1 domains were PCR amplified from 3D7 genomic DNA, expressed in the Baculovirus system and purified by metal-affinity chromatography. The antibody reactivity level to the recombinant PfEMP1 proteins in human hyper-immune plasma was measured by ELISA. In parallel, these recombinant PfEMP1 proteins were covalently coupled onto beads each having its own unique detection signal and the human hyper-immune plasma reactivity was detected for each individual protein using a BioPlex100 system. Protein-coupled beads were analysed at two time points seven months apart, before and after lyophilization and the results compared to determine the effect of storage and lyophilization respectively on the beads. Multiplexed protein-coupled beads from twenty eight unique bead populations were evaluated on the BioPlex100 system against pooled human hyper-immune plasma before and after lyophilization. The bead-based assay was sensitive, accurate and reproducible. Four recombinant PfEMP1 proteins C17, D5, D9 and D12, selected on the basis that they showed a spread of median fluorescent intensity (MFI) values from low to high when analysed by the bead-based assay were analysed by ELISA and the results from both analyses were highly correlated. The Spearman's rank correlation coefficients (Rho) were > or = 0.86, (P < 0.0001) for all comparisons. Bead-based assays gave similar results regardless of whether they were performed on individual beads or on multiplexed beads; lyophilization had no impact on the assay performance. Spearman's rank correlation coefficients (Rho) were > or = 0.97, (P < 0.0001) for all comparisons. Importantly, the reactivity of protein-coupled non-lyophilized beads decreased with long term storage at 4 degrees C in the dark. Using this lyophilized multiplex assay, antibody reactivity levels to twenty eight different recombinant PfEMP1 proteins were simultaneously measured using a single microliter of plasma. Thus, the assay reported here provides a useful tool for rapid and efficient quantification of antibody reactivity against PfEMP1 variants in human plasma.

  20. Acute Lung Injury and Persistent Small Airway Disease in a Rabbit Model of Chlorine Inhalation

    PubMed Central

    Musah, Sadiatu; Schlueter, Connie F.; Humphrey, David M.; Powell, Karen S.; Roberts, Andrew M.; Hoyle, Gary W.

    2016-01-01

    Chlorine is a pulmonary toxicant to which humans can be exposed through accidents or intentional releases. Acute effects of chlorine inhalation in humans and animal models have been well characterized, but less is known about persistent effects of acute, high-level chlorine exposures. In particular, animal models that reproduce the long-term effects suggested to occur in humans are lacking. Here, we report the development of a rabbit model in which both acute and persistent effects of chlorine inhalation can be assessed. Male New Zealand White rabbits were exposed to chlorine while the lungs were mechanically ventilated. After chlorine exposure, the rabbits were extubated and were allowed to survive for up to 24 h after exposure to 800 ppm chlorine for 4 min to study acute effects or up to 7 days after exposure to 400 ppm for 8 min to study longer term effects. Acute effects observed 6 or 24 h after inhalation of 800 ppm chlorine for 4 min included hypoxemia, pulmonary edema, airway epithelial injury, inflammation, altered baseline lung mechanics, and airway hyperreactivity to inhaled methacholine. Seven days after recovery from inhalation of 400 ppm chlorine for 8 min, rabbits exhibited mild hypoxemia, increased area of pressure-volume loops, and airway hyperreactivity. Lung histology 7 days after chlorine exposure revealed abnormalities in the small airways, including inflammation and sporadic bronchiolitis obliterans lesions. Immunostaining showed a paucity of club and ciliated cells in the epithelium at these sites. These results suggest that small airway disease may be an important component of persistent respiratory abnormalities that occur following acute chlorine exposure. This non-rodent chlorine exposure model should prove useful for studying persistent effects of acute chlorine exposure and for assessing efficacy of countermeasures for chlorine-induced lung injury. PMID:27913141

  1. Large volume continuous counterflow dialyzer has high efficiency

    NASA Technical Reports Server (NTRS)

    Mandeles, S.; Woods, E. C.

    1967-01-01

    Dialyzer separates macromolecules from small molecules in large volumes of solution. It takes advantage of the high area/volume ratio in commercially available 1/4-inch dialysis tubing and maintains a high concentration gradient at the dialyzing surface by counterflow.

  2. Ultra-high field NMR and MRI - the role of magnet technology to increase sensitivity and specificity

    NASA Astrophysics Data System (ADS)

    Moser, Ewald; Laistler, Elmar; Schmitt, Franz; Kontaxis, Georg

    2017-08-01

    "History, of course, is difficult to write, if for no other reason, than that it has so many players and so many authors." - P. J. Keating (former Australian Prime Minister) Starting with post-war developments in nuclear magnetic resonance (NMR) a race for stronger and stronger magnetic fields has begun in the 1950s to overcome the inherently low sensitivity of this promising method. Further challenges were larger magnet bores to accommodate small animals and eventually humans. Initially, resistive electromagnets with small pole distances, or sample volumes, and field strengths up to 2.35 T (or 100 MHz 1H frequency) were used in applications in physics, chemistry, and material science. This was followed by stronger and more stable (NbTi based) superconducting magnet technology typically implemented first for small-bore systems in analytical chemistry, biochemistry and structural biology, and eventually allowing larger horizontal-bore magnets with diameters large enough to fit small laboratory animals. By the end of the 1970s, first low-field resistive magnets big enough to accommodate humans were developed and superconducting whole-body systems followed. Currently, cutting-edge analytical NMR systems are available at proton frequencies up to 1 GHz (23.5 T) based on Nb3Sn at 1.9 K. A new 1.2 GHz system (28 T) at 1.9 K, operating in persistent mode but using a combination of low and high temperature multi-filament superconductors is to be released. Preclinical instruments range from small-bore animal systems with typically 600 - 800 MHz (14.1 - 18.8 T) up to 900 MHz (21 T) at 1.9 K. Human whole-body MRI systems currently operate up to 10.5 T. Hybrid combined superconducting and resistive electromagnets with even higher field strength of 45 T dc and 100 T pulsed, are available for material research, of course with smaller free bore diameters. This rather costly development towards higher and higher field strength is a consequence of the inherently low and, thus, urgently needed sensitivity in all NMR experiments. This review particularly describes and compares the developments in superconducting magnet technology and, thus, sensitivity in three fields of research: analytical NMR, biomedical and preclinical research, and human MRI and MRS, highlighting important steps and

  3. Computer-assisted stereological analysis of gastric volume during the human embryonic period.

    PubMed Central

    Macarulla-Sanz, E; Nebot-Cegarra, J; Reina-de la Torre, F

    1996-01-01

    Morphometric data concerning human embryos and fetuses have become more clinically informative since ultrasound was employed to make prenatal measurements and software preprocessing techniques improved the previous fuzzy ultrasound signals (Mahoney, 1992). The aim of this study was to determine the volume of the human stomach during the embryonic period and to compare its rate of growth with that during the early fetal period. To calculate gastric volume, computer imaging techniques were applied on cross sections of a graded series of human embryos (from Carnegie stage 11) and fetuses. Gastric volume increased progressively, except for a decrease between stages 12 and 13 due principally to the reduction of the right gastric wall. The growth of the left wall of the stomach was predominant over that of the right. Until stage 20 the stomach volume increased due to the predominant growth of the walls, after this stage the gastric cavity volume increased rapidly, and the rate of growth of the gastric volume reached similar values to that of the early fetal period. We concluded that in the beginning the human stomach grows due to the predominant growth of its walls, chiefly of the left, and from stage 20 because of the predominant expansion of its cavity, which may be related to the capacity to swallow amniotic fluid at the end of the embryonic period. The diminution of the right gastric wall volume (stages 12-13) is consistent with an extension of the omental bursa into the mesodermal anlage of the stomach. PMID:8621339

  4. Meta-analysis to estimate the load of Leptospira excreted in urine: beyond rats as important sources of transmission in low-income rural communities.

    PubMed

    Barragan, Veronica; Nieto, Nathan; Keim, Paul; Pearson, Talima

    2017-01-28

    Leptospirosis is a major zoonotic disease with widespread distribution and a large impact on human health. Carrier animals excrete pathogenic Leptospira primarily in their urine. Infection occurs when the pathogen enters a host through mucosa or small skin abrasions. Humans and other animals are exposed to the pathogen by direct contact with urine, contaminated soil or water. While many factors influence environmental cycling and the transmission of Leptospira to humans, the load of pathogenic Leptospira in the environment is likely to play a major role. Peridomestic rats are often implicated as a potential source of human disease; however exposure to other animals is a risk factor as well. The aim of this report is to highlight the importance of various carrier animals in terms of the quantity of Leptospira shed into the environment. For this, we performed a systematic literature review and a meta-analysis of the amount of pathogen that various animal species shed in their urine. The quantity of pathogen has been reported for cows, deer, dogs, humans, mice, and rats, in a total of 14 research articles. We estimated the average Leptospira per unit volume shed by each animal species, and the daily environmental contribution by considering the total volume of urine excreted by each carrier animal. Rats excrete the highest quantity of Leptospira per millilitre of urine (median = 5.7 × 10 6  cells), but large mammals excrete much more urine and thus shed significantly more Leptospira per day (5.1 × 10 8 to 1.3 × 10 9  cells). Here we illustrate how, in a low-income rural Ecuadorian community, host population demographics, and prevalence of Leptospira infection can be integrated with estimates of shed Leptospira to suggest that peridomestic cattle may be more important than rats in environmental cycling and ultimately, transmission to humans.

  5. Use of procainamide gels in the purification of human and horse serum cholinesterases.

    PubMed Central

    Ralston, J S; Main, A R; Kilpatrick, B F; Chasson, A L

    1983-01-01

    Two large-scale methods based primarily on the use of procainamide-Sepharose gels were developed for the purification of horse and human serum non-specific cholinesterases. With method I, the procainamide-Sepharose 4B gel was used in the first step to handle large volumes of serum. With method II, the procainamide-Sepharose 4B gel was used in the final step to obtain pure enzyme. Although both methods gave electrophoretically pure cholinesterase preparations in good yields, they were significantly more efficient at purifying the horse enzyme than the human enzyme. To study this problem, the relative binding of human and horse cholinesterases to procainamide-, methylacridinium (MAC)-, m-trimethylammoniophenyl (m-PTA)- and p-trimethylammoniophenyl (p-PTA)-Sepharose 4B gels were measured, by using two approaches. In one, binding was measured by a procedure involving equilibration of pure cholinesterase in a small volume of diluted gel slurry (4%, v/v). A partially purified preparation of Electrophorus acetylcholinesterase was included. Pure human cholinesterase bound consistently more tightly to each of the gels than did horse cholinesterase, and the acetylcholinesterase appeared to bind the gels 10-100 times more tightly than did the non-specific cholinesterases. The order of binding for the cholinesterases, beginning with the tightest, was: procainamide-Sepharose 4B, MAC-Sepharose 4B, p-PTA-Sepharose 4B and m-PTA-Sepharose 4B. For the acetylcholinesterase the order was: MAC-Sepharose 4B, procainamide-Sepharose 4B, p-PTA-Sepharose 4B and m-PTA-Sepharose 4B. The second approach involved passing native sera or partially purified sera fractions through 1 ml test columns of each of the four affinity gels to determine their retention capacity for the cholinesterases. With these impure samples, the MAC-Sepharose 4B gels proved superior to the procainamide-Sepharose 4B gels at retaining human cholinesterase, but the opposite was true for the horse cholinesterase. PMID:6870822

  6. Rewiring food systems to enhance human health and biosphere stewardship

    NASA Astrophysics Data System (ADS)

    Gordon, Line J.; Bignet, Victoria; Crona, Beatrice; Henriksson, Patrik J. G.; Van Holt, Tracy; Jonell, Malin; Lindahl, Therese; Troell, Max; Barthel, Stephan; Deutsch, Lisa; Folke, Carl; Jamila Haider, L.; Rockström, Johan; Queiroz, Cibele

    2017-10-01

    Food lies at the heart of both health and sustainability challenges. We use a social-ecological framework to illustrate how major changes to the volume, nutrition and safety of food systems between 1961 and today impact health and sustainability. These changes have almost halved undernutrition while doubling the proportion who are overweight. They have also resulted in reduced resilience of the biosphere, pushing four out of six analysed planetary boundaries across the safe operating space of the biosphere. Our analysis further illustrates that consumers and producers have become more distant from one another, with substantial power consolidated within a small group of key actors. Solutions include a shift from a volume-focused production system to focus on quality, nutrition, resource use efficiency, and reduced antimicrobial use. To achieve this, we need to rewire food systems in ways that enhance transparency between producers and consumers, mobilize key actors to become biosphere stewards, and re-connect people to the biosphere.

  7. Determination of dioxin-like polychlorinated biphenyls in 1 mL whole blood using programmable temperature vaporization large volume injection coupled to gas chromatogram and high-resolution mass spectrometry.

    PubMed

    Shen, Haitao; Guan, Rongfa; Li, Jingguang; Zhang, Lei; Ren, Yiping; Xu, Xiaomin; Song, Yang; Zhao, Yunfeng; Han, Jianlong; Wu, Yongning

    2013-03-12

    A sensitive method based on programmable temperature vaporization large volume injection coupled to gas chromatogram and high-resolution mass spectrometry (PTV-GC-HRMS) has been developed for the determination of ultra trace levels of dioxin-like polychlorinated biphenyls (DL PCBs) in small amounts of human blood. Blood samples (1mL) were first extracted by column extraction and then purified with column chromatorgraphies. Final extracts (20μL) were introduced to the PTV injector under the solvent vent mode and detected by GC-HRMS (SIM mode). PTV parameters were observed by changing one factor at a time (practical conditions: vent flow: 50mLmin(-1), vent pressure: 0kPa and vent time: 0.1min), recoveries of most PCB congeners ranged from 55.1% to 108%, and method detection limits were in the range of 0.11-1.63pgg(-1). Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Cholecystokinin-producing (I) cells of intestinal mucosa in dexamethasone-treated rats.

    PubMed

    Glišić, Radmila; Koko, Vesna; Cvijić, Gordana; Milošević, Maja Čakić; Obradović, Jasmina

    2011-11-10

    The aim of this study was to investigate the morphological, immunohistochemical and ultrastructural changes of cholecystokinin-producing (I) cells of gastrointestinal mucosa in dexamethasone-treated rats (D). After 12-daily intraperitoneal administration of 2mg/kg dexamethasone, rats developed diabetes similar to human diabetes mellitus type 2. The mean diameter of the duodenum was significantly decreased due to significant reduction of volume fraction and profile area of lamina propria. There was a decrease in volume fraction and number of cholecystokinin (CCK)-producing cells per mm(2) of mucosa, as well as their numerical density, but without statistical significance. Also, dexamethasone induced appearance of hyperactive duodenal I-cells with small number of granules and dilated endoplasmic reticulum. In conclusion, the present study showed that morphological changes in duodenum cholecystokinin-producing (I) cells occurred in diabetic rats, in a manner which, suggests compensatory effort of CCK cells in diabetic condition. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Human protein arginine methyltransferase 7 (PRMT7) is a type III enzyme forming ω-NG-monomethylated arginine residues.

    PubMed

    Zurita-Lopez, Cecilia I; Sandberg, Troy; Kelly, Ryan; Clarke, Steven G

    2012-03-09

    Full-length human protein arginine methyltransferase 7 (PRMT7) expressed as a fusion protein in Escherichia coli was initially found to generate only ω-N(G)-monomethylated arginine residues in small peptides, suggesting that it is a type III enzyme. A later study, however, characterized fusion proteins of PRMT7 expressed in bacterial and mammalian cells as a type II/type I enzyme, capable of producing symmetrically dimethylated arginine (type II activity) as well as small amounts of asymmetric dimethylarginine (type I activity). We have sought to clarify the enzymatic activity of human PRMT7. We analyzed the in vitro methylation products of a glutathione S-transferase (GST)-PRMT7 fusion protein with robust activity using a variety of arginine-containing synthetic peptides and protein substrates, including a GST fusion with the N-terminal domain of fibrillarin (GST-GAR), myelin basic protein, and recombinant human histones H2A, H2B, H3, and H4. Regardless of the methylation reaction conditions (incubation time, reaction volume, and substrate concentration), we found that PRMT7 only produces ω-N(G)-monomethylarginine with these substrates. In control experiments, we showed that mammalian GST-PRMT1 and Myc-PRMT5 were, unlike PRMT7, able to dimethylate both peptide P-SmD3 and SmB/D3 to give the expected asymmetric and symmetric products, respectively. These experiments show that PRMT7 is indeed a type III human methyltransferase capable of forming only ω-N(G)-monomethylarginine, not asymmetric ω-N(G),N(G)-dimethylarginine or symmetric ω-N(G),N(G')-dimethylarginine, under the conditions tested.

  10. Industrial Fuel Gas Demonstration-Plant Program. Volume II. The environment (Deliverable No. 27). [Baseline environmental data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1979-08-01

    The proposed site of the Industrial Fuel Gas Demonstration Plant (IFGDP) is located on a small peninsula extending eastward into Lake McKeller from the south shore. The peninsula is located west-southwest of the City of Memphis near the confluence of Lake McKeller and the Mississippi River. The environmental setting of this site and the region around this site is reported in terms of physical, biological, and human descriptions. Within the physical description, this report divides the environmental setting into sections on physiography, geology, hydrology, water quality, climatology, air quality, and ambient noise. The biological description is divided into sections onmore » aquatic and terrestrial ecology. Finally, the human environment description is reported in sections on land use, demography, socioeconomics, culture, and visual features. This section concludes with a discussion of physical environmental constraints.« less

  11. The physics of large eruptions

    NASA Astrophysics Data System (ADS)

    Gudmundsson, Agust

    2015-04-01

    Based on eruptive volumes, eruptions can be classified as follows: small if the volumes are from less than 0.001 km3 to 0.1 km3, moderate if the volumes are from 0.1 to 10 km3, and large if the volumes are from 10 km3 to 1000 km3 or larger. The largest known explosive and effusive eruptions have eruptive volumes of 4000-5000 km3. The physics of small to moderate eruptions is reasonably well understood. For a typical mafic magma chamber in a crust that behaves as elastic, about 0.1% of the magma leaves the chamber (erupted and injected as a dyke) during rupture and eruption. Similarly, for a typical felsic magma chamber, the eruptive/injected volume during rupture and eruption is about 4%. To provide small to moderate eruptions, chamber volumes of the order of several tens to several hundred cubic kilometres would be needed. Shallow crustal chambers of these sizes are common, and deep-crustal and upper-mantle reservoirs of thousands of cubic kilometres exist. Thus, elastic and poro-elastic chambers of typical volumes can account for small to moderate eruptive volumes. When the eruptions become large, with volumes of tens or hundreds of cubic kilometres or more, an ordinary poro-elastic mechanism can no longer explain the eruptive volumes. The required sizes of the magma chambers and reservoirs to explain such volumes are simply too large to be plausible. Here I propose that the mechanics of large eruptions is fundamentally different from that of small to moderate eruptions. More specifically, I suggest that all large eruptions derive their magmas from chambers and reservoirs whose total cavity-volumes are mechanically reduced very much during the eruption. There are two mechanisms by which chamber/reservoir cavity-volumes can be reduced rapidly so as to squeeze out much of, or all, their magmas. One is piston-like caldera collapse. The other is graben subsidence. During large slip on the ring-faults/graben-faults the associated chamber/reservoir shrinks in volume, thereby maintaining the excess magmatic pressure much longer than is possible in the ordinary poro-elastic mechanism. Here the physics of caldera subsidence and graben subsidence is regarded as basically the same. The geometric difference in the surface expression is simply a reflection of the horizontal cross-sectional shape of the underlying magma body. In this new mechanism, the large eruption is the consequence -- not the cause -- of the caldera/graben subsidence. Thus, once the conditions for large-scale subsidence of a caldera/graben during an unrest period are established, then the likelihood of large to very large eruptions can be assessed and used in reliable forecasting. Gudmundsson, A., 2012. Strengths and strain energies of volcanic edifices: implications for eruptions, collapse calderas and landslides. Nat. Hazards Earth Syst. Sci., 12, 2241-2258. Gudmundsson, A., 2014. Energy release in great earthquakes and eruptions. Front. Earth Science 2:10. doi: 10.3389/feart.2014.00010 Gudmundsson, A., Acocella, V., 2015.Volcanotectonics: Understanding the Structure, Deformation, and Dynamics of Volcanoes. Cambridge University Press (published 2015).

  12. Study on elucidation of bactericidal effects induced by laser beam irradiation Measurement of dynamic stress on laser irradiated surface

    NASA Astrophysics Data System (ADS)

    Furumoto, Tatsuaki; Kasai, Atsushi; Tachiya, Hiroshi; Hosokawa, Akira; Ueda, Takashi

    2010-09-01

    In dental treatment, many types of laser beams have been used for various surgical treatments, and the influences of laser beam irradiation on bactericidal effect have been investigated. However, most of the work has been performed by irradiating to an agar plate with the colony of bacteria, and very few studies have been reported on the physical mechanism of bactericidal effects induced by laser beam irradiation. This paper deals with the measurement of dynamic stress induced in extracted human enamel by irradiation with Nd:YAG laser beams. Laser beams can be delivered to the enamel surface through a quartz optical fiber. Dynamic stress induced in the specimen using elastic wave propagation in a cylindrical long bar made of aluminum alloy is measured. Laser induced stress intensity is evaluated from dynamic strain measured by small semiconductor strain gauges. Carbon powder and titanium dioxide powder were applied to the human enamel surface as absorbents. Additionally, the phenomenon of laser beam irradiation to the human enamel surface was observed with an ultrahigh speed video camera. Results showed that a plasma was generated on the enamel surface during laser beam irradiation, and the melted tissues were scattered in the vertical direction against the enamel surface with a mushroom-like wave. Averaged scattering velocity of the melted tissues was 25.2 m/s. Induced dynamic stress on the enamel surface increased with increasing laser energy in each absorbent. Induced dynamic stresses with titanium dioxide powder were superior to those with carbon powder. Induced dynamic stress was related to volume of prepared cavity, and induced stress for the removal of unit volume of human enamel was 0.03 Pa/mm 3.

  13. Micro-computed tomography assessment of human alveolar bone: bone density and three-dimensional micro-architecture.

    PubMed

    Kim, Yoon Jeong; Henkin, Jeffrey

    2015-04-01

    Micro-computed tomography (micro-CT) is a valuable means to evaluate and secure information related to bone density and quality in human necropsy samples and small live animals. The aim of this study was to assess the bone density of the alveolar jaw bones in human cadaver, using micro-CT. The correlation between bone density and three-dimensional micro architecture of trabecular bone was evaluated. Thirty-four human cadaver jaw bone specimens were harvested. Each specimen was scanned with micro-CT at resolution of 10.5 μm. The bone volume fraction (BV/TV) and the bone mineral density (BMD) value within a volume of interest were measured. The three-dimensional micro architecture of trabecular bone was assessed. All the parameters in the maxilla and the mandible were subject to comparison. The variables for the bone density and the three-dimensional micro architecture were analyzed for nonparametric correlation using Spearman's rho at the significance level of p < .05. A wide range of bone density was observed. There was a significant difference between the maxilla and mandible. All micro architecture parameters were consistently higher in the mandible, up to 3.3 times greater than those in the maxilla. The most linear correlation was observed between BV/TV and BMD, with Spearman's rho = 0.99 (p = .01). Both BV/TV and BMD were highly correlated with all micro architecture parameters with Spearman's rho above 0.74 (p = .01). Two aspects of bone density using micro-CT, the BV/TV and BMD, are highly correlated with three-dimensional micro architecture parameters, which represent the quality of trabecular bone. This noninvasive method may adequately enhance evaluation of the alveolar bone. © 2013 Wiley Periodicals, Inc.

  14. Evaluation of dual energy quantitative CT for determining the spatial distributions of red marrow and bone for dosimetry in internal emitter radiation therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goodsitt, Mitchell M., E-mail: goodsitt@umich.edu; Shenoy, Apeksha; Howard, David

    2014-05-15

    Purpose: To evaluate a three-equation three-unknown dual-energy quantitative CT (DEQCT) technique for determining region specific variations in bone spongiosa composition for improved red marrow dose estimation in radionuclide therapy. Methods: The DEQCT method was applied to 80/140 kVp images of patient-simulating lumbar sectional body phantoms of three sizes (small, medium, and large). External calibration rods of bone, red marrow, and fat-simulating materials were placed beneath the body phantoms. Similar internal calibration inserts were placed at vertebral locations within the body phantoms. Six test inserts of known volume fractions of bone, fat, and red marrow were also scanned. External-to-internal calibration correctionmore » factors were derived. The effects of body phantom size, radiation dose, spongiosa region segmentation granularity [single (∼17 × 17 mm) region of interest (ROI), 2 × 2, and 3 × 3 segmentation of that single ROI], and calibration method on the accuracy of the calculated volume fractions of red marrow (cellularity) and trabecular bone were evaluated. Results: For standard low dose DEQCT x-ray technique factors and the internal calibration method, the RMS errors of the estimated volume fractions of red marrow of the test inserts were 1.2–1.3 times greater in the medium body than in the small body phantom and 1.3–1.5 times greater in the large body than in the small body phantom. RMS errors of the calculated volume fractions of red marrow within 2 × 2 segmented subregions of the ROIs were 1.6–1.9 times greater than for no segmentation, and RMS errors for 3 × 3 segmented subregions were 2.3–2.7 times greater than those for no segmentation. Increasing the dose by a factor of 2 reduced the RMS errors of all constituent volume fractions by an average factor of 1.40 ± 0.29 for all segmentation schemes and body phantom sizes; increasing the dose by a factor of 4 reduced those RMS errors by an average factor of 1.71 ± 0.25. Results for external calibrations exhibited much larger RMS errors than size matched internal calibration. Use of an average body size external-to-internal calibration correction factor reduced the errors to closer to those for internal calibration. RMS errors of less than 30% or about 0.01 for the bone and 0.1 for the red marrow volume fractions would likely be satisfactory for human studies. Such accuracies were achieved for 3 × 3 segmentation of 5 mm slice images for: (a) internal calibration with 4 times dose for all size body phantoms, (b) internal calibration with 2 times dose for the small and medium size body phantoms, and (c) corrected external calibration with 4 times dose and all size body phantoms. Conclusions: Phantom studies are promising and demonstrate the potential to use dual energy quantitative CT to estimate the spatial distributions of red marrow and bone within the vertebral spongiosa.« less

  15. Evaluation of dual energy quantitative CT for determining the spatial distributions of red marrow and bone for dosimetry in internal emitter radiation therapy

    PubMed Central

    Goodsitt, Mitchell M.; Shenoy, Apeksha; Shen, Jincheng; Howard, David; Schipper, Matthew J.; Wilderman, Scott; Christodoulou, Emmanuel; Chun, Se Young; Dewaraja, Yuni K.

    2014-01-01

    Purpose: To evaluate a three-equation three-unknown dual-energy quantitative CT (DEQCT) technique for determining region specific variations in bone spongiosa composition for improved red marrow dose estimation in radionuclide therapy. Methods: The DEQCT method was applied to 80/140 kVp images of patient-simulating lumbar sectional body phantoms of three sizes (small, medium, and large). External calibration rods of bone, red marrow, and fat-simulating materials were placed beneath the body phantoms. Similar internal calibration inserts were placed at vertebral locations within the body phantoms. Six test inserts of known volume fractions of bone, fat, and red marrow were also scanned. External-to-internal calibration correction factors were derived. The effects of body phantom size, radiation dose, spongiosa region segmentation granularity [single (∼17 × 17 mm) region of interest (ROI), 2 × 2, and 3 × 3 segmentation of that single ROI], and calibration method on the accuracy of the calculated volume fractions of red marrow (cellularity) and trabecular bone were evaluated. Results: For standard low dose DEQCT x-ray technique factors and the internal calibration method, the RMS errors of the estimated volume fractions of red marrow of the test inserts were 1.2–1.3 times greater in the medium body than in the small body phantom and 1.3–1.5 times greater in the large body than in the small body phantom. RMS errors of the calculated volume fractions of red marrow within 2 × 2 segmented subregions of the ROIs were 1.6–1.9 times greater than for no segmentation, and RMS errors for 3 × 3 segmented subregions were 2.3–2.7 times greater than those for no segmentation. Increasing the dose by a factor of 2 reduced the RMS errors of all constituent volume fractions by an average factor of 1.40 ± 0.29 for all segmentation schemes and body phantom sizes; increasing the dose by a factor of 4 reduced those RMS errors by an average factor of 1.71 ± 0.25. Results for external calibrations exhibited much larger RMS errors than size matched internal calibration. Use of an average body size external-to-internal calibration correction factor reduced the errors to closer to those for internal calibration. RMS errors of less than 30% or about 0.01 for the bone and 0.1 for the red marrow volume fractions would likely be satisfactory for human studies. Such accuracies were achieved for 3 × 3 segmentation of 5 mm slice images for: (a) internal calibration with 4 times dose for all size body phantoms, (b) internal calibration with 2 times dose for the small and medium size body phantoms, and (c) corrected external calibration with 4 times dose and all size body phantoms. Conclusions: Phantom studies are promising and demonstrate the potential to use dual energy quantitative CT to estimate the spatial distributions of red marrow and bone within the vertebral spongiosa. PMID:24784380

  16. Size distribution and growth rate of crystal nuclei near critical undercooling in small volumes

    NASA Astrophysics Data System (ADS)

    Kožíšek, Z.; Demo, P.

    2017-11-01

    Kinetic equations are numerically solved within standard nucleation model to determine the size distribution of nuclei in small volumes near critical undercooling. Critical undercooling, when first nuclei are detected within the system, depends on the droplet volume. The size distribution of nuclei reaches the stationary value after some time delay and decreases with nucleus size. Only a certain maximum size of nuclei is reached in small volumes near critical undercooling. As a model system, we selected recently studied nucleation in Ni droplet [J. Bokeloh et al., Phys. Rev. Let. 107 (2011) 145701] due to available experimental and simulation data. However, using these data for sample masses from 23 μg up to 63 mg (corresponding to experiments) leads to the size distribution of nuclei, when no critical nuclei in Ni droplet are formed (the number of critical nuclei < 1). If one takes into account the size dependence of the interfacial energy, the size distribution of nuclei increases to reasonable values. In lower volumes (V ≤ 10-9 m3) nucleus size reaches some maximum extreme size, which quickly increases with undercooling. Supercritical clusters continue their growth only if the number of critical nuclei is sufficiently high.

  17. Acute lung injury and persistent small airway disease in a rabbit model of chlorine inhalation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Musah, Sadiatu; Schlueter, Connie F.; Humphrey, Da

    Chlorine is a pulmonary toxicant to which humans can be exposed through accidents or intentional releases. Acute effects of chlorine inhalation in humans and animal models have been well characterized, but less is known about persistent effects of acute, high-level chlorine exposures. In particular, animal models that reproduce the long-term effects suggested to occur in humans are lacking. Here, we report the development of a rabbit model in which both acute and persistent effects of chlorine inhalation can be assessed. Male New Zealand White rabbits were exposed to chlorine while the lungs were mechanically ventilated. After chlorine exposure, the rabbitsmore » were extubated and were allowed to survive for up to 24 h after exposure to 800 ppm chlorine for 4 min to study acute effects or up to 7 days after exposure to 400 ppm for 8 min to study longer term effects. Acute effects observed 6 or 24 h after inhalation of 800 ppm chlorine for 4 min included hypoxemia, pulmonary edema, airway epithelial injury, inflammation, altered baseline lung mechanics, and airway hyperreactivity to inhaled methacholine. Seven days after recovery from inhalation of 400 ppm chlorine for 8 min, rabbits exhibited mild hypoxemia, increased area of pressure–volume loops, and airway hyperreactivity. Lung histology 7 days after chlorine exposure revealed abnormalities in the small airways, including inflammation and sporadic bronchiolitis obliterans lesions. Immunostaining showed a paucity of club and ciliated cells in the epithelium at these sites. These results suggest that small airway disease may be an important component of persistent respiratory abnormalities that occur following acute chlorine exposure. This non-rodent chlorine exposure model should prove useful for studying persistent effects of acute chlorine exposure and for assessing efficacy of countermeasures for chlorine-induced lung injury. - Highlights: • A novel rabbit model of chlorine-induced lung disease was developed. • Acute effects of chlorine were pulmonary edema, hypoxemia and impaired lung function. • Persistent small airway disease developed following recovery from acute injury. • Small airway disease included inflammation and bronchiolitis obliterans lesions. • The model should be useful for studying chlorine lung injury and testing treatments.« less

  18. Cardiovascular regulation in humans in response to oscillatory lower body negative pressure

    NASA Technical Reports Server (NTRS)

    Levenhagen, D. K.; Evans, J. M.; Wang, M.; Knapp, C. F.

    1994-01-01

    The frequency response characteristics of human cardiovascular regulation during hypotensive stress have not been determined. We therefore exposed 10 male volunteers to seven frequencies (0.004-0.1 Hz) of oscillatory lower body negative pressure (OLBNP; 0-50 mmHg). Fourier spectra of arterial pressure (AP), central venous pressure (CVP), stroke volume (SV), cardiac output (CO), heart rate (HR), and total peripheral resistance (TPR) were determined and first harmonic mean, amplitude, and phase angles with respect to OLBNP are presented. AP was relatively well regulated as demonstrated by small oscillations in half amplitude (3.5 mmHg) that were independent of OLBNP frequency and similar to unstressed control spectra. Due to the biomechanics of the system, the magnitudes of oscillations in calf circumference (CC) and CVP decreased with increasing frequency; therefore, we normalized responses by these indexes of the fluid volume shifted. The ratios of oscillations in AP to oscillations in CC increased by an order of magnitude, whereas oscillations in CVP to oscillations in CC and oscillations in AP to oscillations in CVP both tripled between 0.004 and 0.1 Hz. Therefore, even though the amount of fluid shifted by OLBNP decreased with increasing frequency, the magnitude of both CVP and AP oscillations per volume of fluid shifted increased (peaking at 0.08 Hz). The phase relationships between variables, particularly the increasing lags in SV and TPR, but not CVP, indicated that efferent responses with lags of 5-6 s could account for the observed responses. We conclude that, at frequencies below 0.02 Hz, the neural system of humans functioned optimally in regulating AP; OLBNP-induced decreases in SV (by as much as 50%) were counteracted by appropriate oscillations in HR and TPR responses. As OLBNP frequency increased, SV, TPR, and HR oscillations increasingly lagged the input and became less optimally timed for AP regulation.

  19. In Vivo Airway Surface Liquid Cl− Analysis with Solid-State Electrodes

    PubMed Central

    Caldwell, Ray A.; Grubb, Barbara R.; Tarran, Robert; Boucher, Richard C.; Knowles, Michael R.; Barker, Pierre M.

    2002-01-01

    The pathogenesis of cystic fibrosis (CF) airways disease remains controversial. Hypotheses that link mutations in CFTR and defects in ion transport to CF lung disease predict that alterations in airway surface liquid (ASL) isotonic volume, or ion composition, are critically important. ASL [Cl−] is pivotal in discriminating between these hypotheses, but there is no consensus on this value given the difficulty in measuring [Cl−] in the “thin” ASL (∼30 μm) in vivo. Consequently, a miniaturized solid-state electrode with a shallow depth of immersion was constructed to measure ASL [Cl−] in vivo. In initial experiments, the electrode measured [Cl−] in physiologic salt solutions, small volume (7.6 μl) test solutions, and in in vitro cell culture models, with ≥93% accuracy. Based on discrepancies in reported values and/or absence of data, ASL Cl− measurements were made in the following airway regions and species. First, ASL [Cl−] was measured in normal human nasal cavity and averaged 117.3 ± 11.2 mM (n = 6). Second, ASL [Cl−] measured in large airway (tracheobronchial) regions were as follows: rabbit trachea and bronchus = 114.3 ± 1.8 mM; (n = 6) and 126.9 ± 1.7 mM; (n = 3), respectively; mouse trachea = 112.8 ± 4.2 mM (n = 13); and monkey bronchus = 112.3 ± 10.9 mM (n = 3). Third, Cl− measurements were made in small (1–2 mm) diameter airways of the rabbit (108.3 ± 7.1 mM, n = 5) and monkey (128.5 ± 6.8 mM, n = 3). The measured [Cl−], in excess of 100 mM throughout all airway regions tested in multiple species, is consistent with the isotonic volume hypothesis to describe ASL physiology. PMID:11773234

  20. Runoff thresholds and land-to-marine ecosystem connectivity in a dry tropical setting: St. John, US Virgin Islands

    NASA Astrophysics Data System (ADS)

    Ramos-Scharron, C. E.; LaFevor, M. C.; Roy, J.

    2017-12-01

    Developing a conceptually sound yet practical understanding of runoff and sediment delivery from human occupied lands to tropical ocean waters still represents a pivotal need of coral reef management worldwide. In the dry tropical and ephemeral streamflow setting that typifies the small watersheds ( 1s km2) draining the US Virgin Islands, changes in hydrologic and sediment delivery dynamics provoked by unsurfaced road networks represent a major threat to coral reefs and other sensitive marine ecosystems. Through a combined empirical and modeling approach, this study evaluates how road building and associated stormflow restoration strategies affect rainfall thresholds for runoff generation at varying spatial scales and their impact on land-to-sea connectivity. Rainfall thresholds and runoff coefficients for precipitation excess on unpaved roads are 2-3 mm and 22-30% (respectively) or a full order of magnitude different from those for undisturbed hillslopes and watersheds. Here we discuss the use of a `volume-to-breakthrough' inspired index to predict the potential of road runoff to reach downslope portions of the watershed and the coastline as runon. The index integrates the effects of storm-by-storm runoff accumulation for every road drainage point with its flow distance to specific locations along the stream network. While large runoff volumes and short flow distances imply a relatively high connectivity potential, small volumes and long distances are associated to low delivery potential. The index has proven able to discern observed runoff responses under a variety of road-stream network scenarios and rainfall conditions. These results enhance our understanding of ephemeral stream hydrology and are serving to improve coral reef management strategies throughout the Northeastern Caribbean.

  1. Use of small volume cups in XRF analysis of treated wood retention

    Treesearch

    Rene Stelzer; Adam Taylor; Patricia Lebow

    2017-01-01

    Efforts are underway in the United States to improve the conformance of commercially-treated wood with the applicable retention standards. As part of an effort to devise a practical method for on-site assessment of within-charge retention variation, we investigated whether small-volume x-ray fluorescence (XRF) sample cups could be used with treated wood. A range of cup...

  2. Applying a crop-tree release in small-sawtimber white oak stands

    Treesearch

    Jeffrey W Stringer; Gary W. Miller; Robert F. Wittwer; Robert F. Wittwer

    1988-01-01

    Small-sawtimber white oak crop trees in Kentucky were released by a crown-touching technique. In two cutting treatments, 20 and 34 crop trees were released per acre at a total cost of $35 and $42, respectively. Both treatments yielded commercial volumes of cut material. Total mean merchantable volume (> 5.0 inches d.b.h.) in cut trees was 693 cubic feet/acre, with...

  3. SU-E-T-427: Cell Surviving Fractions Derived From Tumor-Volume Variation During Radiotherapy for Non-Small Cell Lung Cancer: Comparison with Predictive Assays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chvetsov, A; Schwartz, J; Mayr, N

    2014-06-01

    Purpose: To show that a distribution of cell surviving fractions S{sub 2} in a heterogeneous group of patients can be derived from tumor-volume variation curves during radiotherapy for non-small cell lung cancer. Methods: Our analysis was based on two data sets of tumor-volume variation curves for heterogeneous groups of 17 patients treated for nonsmall cell lung cancer with conventional dose fractionation. The data sets were obtained previously at two independent institutions by using megavoltage (MV) computed tomography (CT). Statistical distributions of cell surviving fractions S{sup 2} and cell clearance half-lives of lethally damaged cells T1/2 have been reconstructed in eachmore » patient group by using a version of the two-level cell population tumor response model and a simulated annealing algorithm. The reconstructed statistical distributions of the cell surviving fractions have been compared to the distributions measured using predictive assays in vitro. Results: Non-small cell lung cancer presents certain difficulties for modeling surviving fractions using tumor-volume variation curves because of relatively large fractional hypoxic volume, low gradient of tumor-volume response, and possible uncertainties due to breathing motion. Despite these difficulties, cell surviving fractions S{sub 2} for non-small cell lung cancer derived from tumor-volume variation measured at different institutions have similar probability density functions (PDFs) with mean values of 0.30 and 0.43 and standard deviations of 0.13 and 0.18, respectively. The PDFs for cell surviving fractions S{sup 2} reconstructed from tumor volume variation agree with the PDF measured in vitro. Comparison of the reconstructed cell surviving fractions with patient survival data shows that the patient survival time decreases as the cell surviving fraction increases. Conclusion: The data obtained in this work suggests that the cell surviving fractions S{sub 2} can be reconstructed from the tumor volume variation curves measured during radiotherapy with conventional fractionation. The proposed method can be used for treatment evaluation and adaptation.« less

  4. Parallel production and verification of protein products using a novel high-throughput screening method.

    PubMed

    Tegel, Hanna; Yderland, Louise; Boström, Tove; Eriksson, Cecilia; Ukkonen, Kaisa; Vasala, Antti; Neubauer, Peter; Ottosson, Jenny; Hober, Sophia

    2011-08-01

    Protein production and analysis in a parallel fashion is today applied in laboratories worldwide and there is a great need to improve the techniques and systems used for this purpose. In order to save time and money, a fast and reliable screening method for analysis of protein production and also verification of the protein product is desired. Here, a micro-scale protocol for the parallel production and screening of 96 proteins in plate format is described. Protein capture was achieved using immobilized metal affinity chromatography and the product was verified using matrix-assisted laser desorption ionization time-of-flight MS. In order to obtain sufficiently high cell densities and product yield in the small-volume cultivations, the EnBase® cultivation technology was applied, which enables cultivation in as small volumes as 150 μL. Here, the efficiency of the method is demonstrated by producing 96 human, recombinant proteins, both in micro-scale and using a standard full-scale protocol and comparing the results in regard to both protein identity and sample purity. The results obtained are highly comparable to those acquired through employing standard full-scale purification protocols, thus validating this method as a successful initial screening step before protein production at a larger scale. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Rural Schools Prototype Analysis. Volume II: Methodology. An Example Process of Identifying Determinants, Selecting Options, & Developing Schematic Designs.

    ERIC Educational Resources Information Center

    Construction Systems Management, Inc., Anchorage, AK.

    Volume II of a 3-volume report demonstrates the use of Design Determinants and Options (presented in Volume I) in the planning and design of small rural Alaskan secondary schools. Section I, a checklist for gathering site-specific information to be used as a data base for facility design, is organized in the same format as Volume I, which can be…

  6. Allometric Analysis Detects Brain Size-Independent Effects of Sex and Sex Chromosome Complement on Human Cerebellar Organization.

    PubMed

    Mankiw, Catherine; Park, Min Tae M; Reardon, P K; Fish, Ari M; Clasen, Liv S; Greenstein, Deanna; Giedd, Jay N; Blumenthal, Jonathan D; Lerch, Jason P; Chakravarty, M Mallar; Raznahan, Armin

    2017-05-24

    The cerebellum is a large hindbrain structure that is increasingly recognized for its contribution to diverse domains of cognitive and affective processing in human health and disease. Although several of these domains are sex biased, our fundamental understanding of cerebellar sex differences-including their spatial distribution, potential biological determinants, and independence from brain volume variation-lags far behind that for the cerebrum. Here, we harness automated neuroimaging methods for cerebellar morphometrics in 417 individuals to (1) localize normative male-female differences in raw cerebellar volume, (2) compare these to sex chromosome effects estimated across five rare sex (X/Y) chromosome aneuploidy (SCA) syndromes, and (3) clarify brain size-independent effects of sex and SCA on cerebellar anatomy using a generalizable allometric approach that considers scaling relationships between regional cerebellar volume and brain volume in health. The integration of these approaches shows that (1) sex and SCA effects on raw cerebellar volume are large and distributed, but regionally heterogeneous, (2) human cerebellar volume scales with brain volume in a highly nonlinear and regionally heterogeneous fashion that departs from documented patterns of cerebellar scaling in phylogeny, and (3) cerebellar organization is modified in a brain size-independent manner by sex (relative expansion of total cerebellum, flocculus, and Crus II-lobule VIIIB volumes in males) and SCA (contraction of total cerebellar, lobule IV, and Crus I volumes with additional X- or Y-chromosomes; X-specific contraction of Crus II-lobule VIIIB). Our methods and results clarify the shifts in human cerebellar organization that accompany interwoven variations in sex, sex chromosome complement, and brain size. SIGNIFICANCE STATEMENT Cerebellar systems are implicated in diverse domains of sex-biased behavior and pathology, but we lack a basic understanding of how sex differences in the human cerebellum are distributed and determined. We leverage a rare neuroimaging dataset to deconvolve the interwoven effects of sex, sex chromosome complement, and brain size on human cerebellar organization. We reveal topographically variegated scaling relationships between regional cerebellar volume and brain size in humans, which (1) are distinct from those observed in phylogeny, (2) invalidate a traditional neuroimaging method for brain volume correction, and (3) allow more valid and accurate resolution of which cerebellar subcomponents are sensitive to sex and sex chromosome complement. These findings advance understanding of cerebellar organization in health and sex chromosome aneuploidy. Copyright © 2017 the authors 0270-6474/17/375222-11$15.00/0.

  7. 40 CFR 82.176 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... of an otherwise unacceptable substitute. (3) Small volume use within SNAP sectors. Within the nine principal SNAP sectors, persons introducing a substitute whose expected volume of use amounts to less than.... Notification shall include the name of the substitute, the volume used in the test marketing, intended sector...

  8. 40 CFR 82.176 - Applicability.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... of an otherwise unacceptable substitute. (3) Small volume use within SNAP sectors. Within the nine principal SNAP sectors, persons introducing a substitute whose expected volume of use amounts to less than.... Notification shall include the name of the substitute, the volume used in the test marketing, intended sector...

  9. Validation of a New Small-Volume Sodium Citrate Collection Tube for Coagulation Testing in Critically Ill Patients with Coagulopathy.

    PubMed

    Adam, Elisabeth H; Zacharowski, Kai; Hintereder, Gudrun; Raimann, Florian; Meybohm, Patrick

    2018-06-01

    Blood loss due to phlebotomy leads to hospital-acquired anemia and more frequent blood transfusions that may be associated with increased risk of morbidity and mortality in critically ill patients. Multiple blood conservation strategies have been proposed in the context of patient blood management to minimize blood loss. Here, we evaluated a new small-volume sodium citrate collection tube for coagulation testing in critically ill patients. In 46 critically adult ill patients admitted to an interdisciplinary intensive care unit, we prospectively compared small-volume (1.8 mL) sodium citrate tubes with the conventional (3 mL) sodium citrate tubes. The main inclusion criterium was a proven coagulopathy (Quick < 60% and/or aPTT > 40 second) due to anticoagulation therapy or perioperative coagulopathy. In total, 92 coagulation analyses were obtained. Linear correlation analysis detected a positive relationship for 7 coagulation parameters (Prothrombin Time, r = 0.987; INR, r = 0.985; activated Partial Thromboplastin Time, r = 0.967; Thrombin Clotting Time, r = 0.969; Fibrinogen, r = 0.986; Antithrombin, r = 0.988; DDimer, r = 0.969). Bland-Altman analyses revealed an absolute mean of differences of almost zero. Ninety-five percent of data were within two standard deviations of the mean difference suggesting interchangeability. As systematic deviations between measured parameters of the two tubes were very unlikely, test results of small-volume (1.8 mL) sodium citrate tubes were equal to conventional (3 mL) sodium citrate tubes and can be considered interchangeable. Small-volume sodium citrate tubes reduced unnecessary diagnostic-related blood loss by about 40% and, therefore, should be the new standard of care for routine coagulation analysis in critically ill patients.

  10. Cell volumes, maximal growth rates of unicellular algae and ciliates, and the role of ciliates in the marine pelagial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Banse, K.

    1982-01-01

    A review of growth rates of diatoms and dinoflagellates in light-saturated, nutrient-replete cultures at 20/sup 0/C confirms weak dependence on cell volume or mass. These maximal (intrinsic) rates are not linearly related to surface area or surface-to-volume ratio of the cells. The growth of most diatoms is materially faster than that of dinoflagellates; other algae fall in between or below the dinoflagellates. Small ciliates have appreciably higher intrinsic growth rates than algae of the same cell volume. The average food consumption per ciliate in the marine pelagic realm is inferred to be very low, so that the realized specific growthmore » rates are much smaller than the intrinsic potentials. Also, a previously postulated refuge from predation, afforded by small size, is extended down to about 10-..mu..m/sup 3/ cell volume.« less

  11. "Small World" architecture in brain connectivity and hippocampal volume in Alzheimer's disease: a study via graph theory from EEG data.

    PubMed

    Vecchio, Fabrizio; Miraglia, Francesca; Piludu, Francesca; Granata, Giuseppe; Romanello, Roberto; Caulo, Massimo; Onofrj, Valeria; Bramanti, Placido; Colosimo, Cesare; Rossini, Paolo Maria

    2017-04-01

    Brain imaging plays an important role in the study of Alzheimer's disease (AD), where atrophy has been found to occur in the hippocampal formation during the very early disease stages and to progress in parallel with the disease's evolution. The aim of the present study was to evaluate a possible correlation between "Small World" characteristics of the brain connectivity architecture-as extracted from EEG recordings-and hippocampal volume in AD patients. A dataset of 144 subjects, including 110 AD (MMSE 21.3) and 34 healthy Nold (MMSE 29.8) individuals, was evaluated. Weighted and undirected networks were built by the eLORETA solutions of the cortical sources' activities moving from EEG recordings. The evaluation of the hippocampal volume was carried out on a subgroup of 60 AD patients who received a high-resolution T1-weighted sequence and underwent processing for surface-based cortex reconstruction and volumetric segmentation using the Freesurfer image analysis software. Results showed that, quantitatively, more correlation was observed in the right hemisphere, but the same trend was seen in both hemispheres. Alpha band connectivity was negatively correlated, while slow (delta) and fast-frequency (beta, gamma) bands positively correlated with hippocampal volume. Namely, the larger the hippocampal volume, the lower the alpha and the higher the delta, beta, and gamma Small World characteristics of connectivity. Accordingly, the Small World connectivity pattern could represent a functional counterpart of structural hippocampal atrophying and related-network disconnection.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nguyen, Paul L., E-mail: E-pnguyen@LROC.harvard.ed; Harvard Medical School, Boston, MA; Chen, Ming H.

    Background: Brachytherapy for prostate cancer can be technically challenging in men with small prostates ({<=}20 cc), but it is unknown whether their outcomes are different than those of men with larger prostates. Methods and Materials: We studied 6,416 men treated with brachytherapy in one of 21 community-based practices. Cox regression and Fine and Gray's regression were used to determine whether volume {<=}20 cc was associated with a higher risk of all-cause mortality (ACM) or prostate cancer-specific mortality (PCSM), respectively, after adjustment for other known prognostic factors. Results: 443 patients (6.9%) had a prostate volume {<=}20 cc. After a median follow-upmore » of 2.91 years (interquartile range, 1.06-4.79), volume {<=}20 cc was associated with a significantly higher risk of ACM (adjusted hazard ratio = 1.33 [95% CI 1.08-1.65], p = 0.0085) with 3-year estimates of ACM for {<=}20 cc vs. >20 cc of 13.0% vs. 6.9% (p = 0.028). Only 23 men (0.36%) have died of prostate cancer, and no difference was seen in PCSM by volume (p = 0.4). Conclusion: Men with small prostates at the time of implant had a 33% higher risk of ACM, and the underlying cause of this remains uncertain. No increase in PCSM was observed in men with volume {<=}20cc, suggesting that a small prostate should not in itself be a contraindication for brachytherapy, but inasmuch as absolute rates of PCSM were small, further follow-up will be needed to confirm this finding.« less

  13. A mass-density model can account for the size-weight illusion

    PubMed Central

    Bergmann Tiest, Wouter M.; Drewing, Knut

    2018-01-01

    When judging the heaviness of two objects with equal mass, people perceive the smaller and denser of the two as being heavier. Despite the large number of theories, covering bottom-up and top-down approaches, none of them can fully account for all aspects of this size-weight illusion and thus for human heaviness perception. Here we propose a new maximum-likelihood estimation model which describes the illusion as the weighted average of two heaviness estimates with correlated noise: One estimate derived from the object’s mass, and the other from the object’s density, with estimates’ weights based on their relative reliabilities. While information about mass can directly be perceived, information about density will in some cases first have to be derived from mass and volume. However, according to our model at the crucial perceptual level, heaviness judgments will be biased by the objects’ density, not by its size. In two magnitude estimation experiments, we tested model predictions for the visual and the haptic size-weight illusion. Participants lifted objects which varied in mass and density. We additionally varied the reliability of the density estimate by varying the quality of either visual (Experiment 1) or haptic (Experiment 2) volume information. As predicted, with increasing quality of volume information, heaviness judgments were increasingly biased towards the object’s density: Objects of the same density were perceived as more similar and big objects were perceived as increasingly lighter than small (denser) objects of the same mass. This perceived difference increased with an increasing difference in density. In an additional two-alternative forced choice heaviness experiment, we replicated that the illusion strength increased with the quality of volume information (Experiment 3). Overall, the results highly corroborate our model, which seems promising as a starting point for a unifying framework for the size-weight illusion and human heaviness perception. PMID:29447183

  14. A mass-density model can account for the size-weight illusion.

    PubMed

    Wolf, Christian; Bergmann Tiest, Wouter M; Drewing, Knut

    2018-01-01

    When judging the heaviness of two objects with equal mass, people perceive the smaller and denser of the two as being heavier. Despite the large number of theories, covering bottom-up and top-down approaches, none of them can fully account for all aspects of this size-weight illusion and thus for human heaviness perception. Here we propose a new maximum-likelihood estimation model which describes the illusion as the weighted average of two heaviness estimates with correlated noise: One estimate derived from the object's mass, and the other from the object's density, with estimates' weights based on their relative reliabilities. While information about mass can directly be perceived, information about density will in some cases first have to be derived from mass and volume. However, according to our model at the crucial perceptual level, heaviness judgments will be biased by the objects' density, not by its size. In two magnitude estimation experiments, we tested model predictions for the visual and the haptic size-weight illusion. Participants lifted objects which varied in mass and density. We additionally varied the reliability of the density estimate by varying the quality of either visual (Experiment 1) or haptic (Experiment 2) volume information. As predicted, with increasing quality of volume information, heaviness judgments were increasingly biased towards the object's density: Objects of the same density were perceived as more similar and big objects were perceived as increasingly lighter than small (denser) objects of the same mass. This perceived difference increased with an increasing difference in density. In an additional two-alternative forced choice heaviness experiment, we replicated that the illusion strength increased with the quality of volume information (Experiment 3). Overall, the results highly corroborate our model, which seems promising as a starting point for a unifying framework for the size-weight illusion and human heaviness perception.

  15. Recombinant human hyaluronidase PH20 (rHuPH20) facilitates subcutaneous infusions of large volumes of immunoglobulin in a swine model.

    PubMed

    Kang, David W; Jadin, Laurence; Nekoroski, Tara; Drake, Fred H; Zepeda, Monica L

    2012-08-01

    Many patients with primary immunodeficiency disease (PIDD) require lifelong immunoglobulin (Ig) replacement therapy. Home-based subcutaneous (SC) infusion provides advantages to patients with PIDD compared to hospital-based intravenous infusion. One limitation of current practice with SCIg infusion is the need for small-volume infusions at multiple injection sites on a frequent basis. A method was developed for large-volume SC infusion that uses preinfusion of recombinant human hyaluronidase (rHuPH20) to facilitate fluid dispersion. Miniature swine was used as a preclinical model to assess the effects of rHuPH20-facilitated infusions, of a single monthly dose, on fluid dispersion, infusion-related pressure, swelling, induration, and tissue damage. Preinfusion of vehicle (control) or rHuPH20 (75 U/g Ig) was performed simultaneously on contralateral abdominal sites on each animal, followed by infusion of 300 mL 10 % Ig (30 g) at each site. Compared to control infusions, rHuPH20 significantly reduced infusion pressure and induration (p < 0.05) and accelerated postinfusion Ig dispersion. Histological evaluation of infusion site tissue showed moderate to severe swelling for the control. Swelling after rHuPH20-facilitated infusion was mild on day 1 and had completely resolved shortly thereafter. Laser Doppler imaging of control infusion sites revealed local cutaneous hypoperfusion during Ig infusion, which was reduced almost 7-fold (p < 0.05) with the use of rHuPH20. These results demonstrate that rHuPH20-facilitated Ig infusion is associated with improved dispersion of Ig, resulting in reduced tissue pressure, induration, and reduced risk of tissue damage from mechanical trauma or local ischemia, thus enabling SC administration of large volumes of Ig at a single site.

  16. Large Volume, Behaviorally-relevant Illumination for Optogenetics in Non-human Primates.

    PubMed

    Acker, Leah C; Pino, Erica N; Boyden, Edward S; Desimone, Robert

    2017-10-03

    This protocol describes a large-volume illuminator, which was developed for optogenetic manipulations in the non-human primate brain. The illuminator is a modified plastic optical fiber with etched tip, such that the light emitting surface area is > 100x that of a conventional fiber. In addition to describing the construction of the large-volume illuminator, this protocol details the quality-control calibration used to ensure even light distribution. Further, this protocol describes techniques for inserting and removing the large volume illuminator. Both superficial and deep structures may be illuminated. This large volume illuminator does not need to be physically coupled to an electrode, and because the illuminator is made of plastic, not glass, it will simply bend in circumstances when traditional optical fibers would shatter. Because this illuminator delivers light over behaviorally-relevant tissue volumes (≈ 10 mm 3 ) with no greater penetration damage than a conventional optical fiber, it facilitates behavioral studies using optogenetics in non-human primates.

  17. Influence of parental care on offspring hippocampal volume in young adults varies as a function of overprotection

    PubMed Central

    Wang, Yinan; Song, Yiying; Li, Xueting; Zhang, Lin; Liu, Jia

    2017-01-01

    Parental care results in increased hippocampal volumes through adaptive stress responses in developing animals. However, human studies have not yet provided consistent findings analogous to the animal literature, possibly because parental care in humans is likely intermingled with parental overprotection, as suggested by the optimal parenting theory. Here, we tested the hypothesis that the effect of parental care on offspring hippocampal volume varies as a function of parental overprotection with a large cohort of young adult participants (N = 257). Consistent with some previous human studies, we found that parental care in childhood alone had little association with the hippocampal volume in adulthood. However, when parental overprotection was low, parental care was positively correlated with offspring hippocampal volume, whereas there was no association between parental care and offspring hippocampal volume when parental overprotection was high. Thus, an interaction exists between parental care and overprotection in human’s hippocampal development, which contributes to the elucidation of the complex relationship between brain structure and environmental factors. PMID:28401913

  18. Modelling dynamic changes in blood flow and volume in the cerebral vasculature.

    PubMed

    Payne, S J; El-Bouri, W K

    2018-08-01

    The cerebral microvasculature plays a key role in the transport of blood and the delivery of nutrients to the cells that perform brain function. Although recent advances in experimental imaging techniques mean that its structure and function can be interrogated to very small length scales, allowing individual vessels to be mapped to a fraction of 1 μm, these techniques currently remain confined to animal models. In-vivo human data can only be obtained at a much coarser length scale, of order 1 mm, meaning that mathematical models of the microvasculature play a key role in interpreting flow and metabolism data. However, there are close to 10,000 vessels even within a single voxel of size 1 mm 3 . Given the number of vessels present within a typical voxel and the complexity of the governing equations for flow and volume changes, it is computationally challenging to solve these in full, particularly when considering dynamic changes, such as those found in response to neural activation. We thus consider here the governing equations and some of the simplifications that have been proposed in order more rigorously to justify in what generations of blood vessels these approximations are valid. We show that two approximations (neglecting the advection term and assuming a quasi-steady state solution for blood volume) can be applied throughout the cerebral vasculature and that two further approximations (a simple first order differential relationship between inlet and outlet flows and inlet and outlet pressures, and matching of static pressure at nodes) can be applied in vessels smaller than approximately 1 mm in diameter. We then show how these results can be applied in solving flow fields within cerebral vascular networks providing a simplified yet rigorous approach to solving dynamic flow fields and compare the results to those obtained with alternative approaches. We thus provide a framework to model cerebral blood flow and volume within the cerebral vasculature that can be used, particularly at sub human imaging length scales, to provide greater insight into the behaviour of blood flow and volume in the cerebral vasculature. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Development of Human Muscle Protein Measurement with MRI

    NASA Technical Reports Server (NTRS)

    Lin, Chen; Evans, Harlan; Leblanc, Adrian D.

    1997-01-01

    It is known that micro-gravity has a strong influence on the human musculoskeletal system. A number of studies have shown that significant changes in skeletal muscles occur in both space flight and bedrest simulation. In our 5 week bedrest study, the cross-sectional area of soleus-gastrocnemius decreased about 12% while the cross-sectional area of anterior calf muscles decreased about 4%. Using volume measurements, these losses increased after 17 weeks to approximately 30% and 21% respectively. Significant muscle atrophy was also found on the SL-J crew members after only 8 days in space. It is important that these effects are fully understood so that countermeasures can be developed. The same knowledge might also be useful in preventing muscle atrophy related to other medical problems. A major problem with anatomical measurements of muscle during bed rest and microgravity is the influence of fluid shifts and water balance on the measurement of muscle volume, especially when the exposure duration is short and the atrophy is relatively small. Fluid shifts were documented in Skylab by visual observations of blood vessel distention, rapid changes in limb volume, center of mass measurements and subjective descriptions such as puffy faces and head fullness. It has been reported that the muscle water content of biopsied soleus muscles decreased following 8 hours of head down tilt bed rest. Three aspects of fluid shifts that can affect volume measurements are: first, the shift of fluid that occurs whenever there is a change from upright to a recumbent position and vice versa; second, the potential for fluid accumulation in the lower limbs resulting from muscle damage caused by overextending atrophied muscle or swelling caused by deconditioned precapillary sphincter muscles during reambulation; third, the net change of hydration level during and after bed rest or spaceflight. Because of these transitory fluid shifts, muscle protein is expected to represent muscle capacity better than does muscle volume. The purpose of this study is to test the feasibility of using MRI to quantify of muscle protein and water content changes in muscle.

  20. Lacunar Infarcts, but Not Perivascular Spaces, Are Predictors of Cognitive Decline in Cerebral Small-Vessel Disease

    PubMed Central

    Trippier, Sarah; Lawrence, Andrew J.; Lambert, Christian; Zeestraten, Eva; Williams, Owen A.; Patel, Bhavini; Morris, Robin G.; Barrick, Thomas R.; MacKinnon, Andrew D.; Markus, Hugh S.

    2018-01-01

    Background and Purpose— Cerebral small-vessel disease is a major cause of cognitive impairment. Perivascular spaces (PvS) occur in small-vessel disease, but their relationship to cognitive impairment remains uncertain. One reason may be difficulty in distinguishing between lacunes and PvS. We determined the relationship between baseline PvS score and PvS volume with change in cognition over a 5-year follow-up. We compared this to the relationship between baseline lacune count and total lacune volume with cognition. In addition, we examined change in PvS volume over time. Methods— Data from the prospective SCANS study (St Georges Cognition and Neuroimaging in Stroke) of patients with symptomatic lacunar stroke and confluent leukoaraiosis were used (n=121). Multimodal magnetic resonance imaging was performed annually for 3 years and neuropsychological testing annually for 5 years. Lacunes were manually identified and distinguished from PvS. PvS were rated using a validated visual rating scale, and PvS volumes calculated using T1-weighted images. Linear mixed-effect models were used to determine the impact of PvS and lacunes on cognition. Results— Baseline PvS scores or volumes showed no association with cognitive indices. No change was detectable in PvS volumes over the 3 years. In contrast, baseline lacunes associated with all cognitive indices and predicted cognitive decline over the 5-year follow-up. Conclusions— Although a feature of small-vessel disease, PvS are not a predictor of cognitive decline, in contrast to lacunes. This study highlights the importance of carefully differentiating between lacunes and PvS in studies investigating vascular cognitive impairment. PMID:29438074

  1. Data package for the Low-Level Waste Disposal Development and Demonstration Program environmental impact statement: Volume 2, Appendices E-O

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ketelle, R.H.

    1988-09-01

    This volume contains 11 appendices to the main document in Volume 1. Topics in Volume 2 include hydrologic data for a proposed solid waste storage area, soil characterizations, well logs, surface water discharge data, water quality data, atmospheric precipitation and stream flow, a small mammal survey, and general ecological information. (TEM)

  2. A field test of cut-off importance sampling for bole volume

    Treesearch

    Jeffrey H. Gove; Harry T. Valentine; Michael J. Holmes

    2000-01-01

    Cut-off importance sampling has recently been introduced as a technique for estimating bole volume to some point below the tree tip, termed the cut-off point. A field test of this technique was conducted on a small population of eastern white pine trees using dendrometry as the standard for volume estimation. Results showed that the differences in volume estimates...

  3. Tumor Volume Is a Prognostic Factor in Non-Small-Cell Lung Cancer Treated With Chemoradiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alexander, Brian M.; Othus, Megan; Caglar, Hale B.

    2011-04-01

    Purpose: To investigate whether primary tumor and nodal volumes defined on radiotherapy planning scans are correlated with outcome (survival and recurrence) after combined-modality treatment. Methods and Materials: A retrospective review of patients with Stage III non-small-cell lung cancer treated with chemoradiation at Brigham and Women's Hospital/Dana-Farber Cancer Institute from 2000 to 2006 was performed. Tumor and nodal volume measurements, as computed by Eclipse (Varian, Palo Alto, CA), were used as independent variables, along with existing clinical factors, in univariate and multivariate analyses for association with outcomes. Results: For patients treated with definitive chemoradiotherapy, both nodal volume (hazard ratio [HR], 1.09;more » p < 0.01) and tumor volume (HR, 1.03; p < 0.01) were associated with overall survival on multivariate analysis. Both nodal volume (HR, 1.10; p < 0.01) and tumor volume (HR, 1.04; p < 0.01) were also associated with local control but not distant metastases. Conclusions: In addition to traditional surgical staging variables, disease burden, measured by primary tumor and nodal metastases volume, provides information that may be helpful in determining prognosis and identifying groups of patients for which more aggressive local therapy is warranted.« less

  4. Intensity modulated radiation therapy (IMRT): differences in target volumes and improvement in clinically relevant doses to small bowel in rectal carcinoma.

    PubMed

    Mok, Henry; Crane, Christopher H; Palmer, Matthew B; Briere, Tina M; Beddar, Sam; Delclos, Marc E; Krishnan, Sunil; Das, Prajnan

    2011-06-08

    A strong dose-volume relationship exists between the amount of small bowel receiving low- to intermediate-doses of radiation and the rates of acute, severe gastrointestinal toxicity, principally diarrhea. There is considerable interest in the application of highly conformal treatment approaches, such as intensity-modulated radiation therapy (IMRT), to reduce dose to adjacent organs-at-risk in the treatment of carcinoma of the rectum. Therefore, we performed a comprehensive dosimetric evaluation of IMRT compared to 3-dimensional conformal radiation therapy (3DCRT) in standard, preoperative treatment for rectal cancer. Using RTOG consensus anorectal contouring guidelines, treatment volumes were generated for ten patients treated preoperatively at our institution for rectal carcinoma, with IMRT plans compared to plans derived from classic anatomic landmarks, as well as 3DCRT plans treating the RTOG consensus volume. The patients were all T3, were node-negative (N = 1) or node-positive (N = 9), and were planned to a total dose of 45-Gy. Pairwise comparisons were made between IMRT and 3DCRT plans with respect to dose-volume histogram parameters. IMRT plans had superior PTV coverage, dose homogeneity, and conformality in treatment of the gross disease and at-risk nodal volume, in comparison to 3DCRT. Additionally, in comparison to the 3DCRT plans, IMRT achieved a concomitant reduction in doses to the bowel (small bowel mean dose: 18.6-Gy IMRT versus 25.2-Gy 3DCRT; p = 0.005), bladder (V40Gy: 56.8% IMRT versus 75.4% 3DCRT; p = 0.005), pelvic bones (V40Gy: 47.0% IMRT versus 56.9% 3DCRT; p = 0.005), and femoral heads (V40Gy: 3.4% IMRT versus 9.1% 3DCRT; p = 0.005), with an improvement in absolute volumes of small bowel receiving dose levels known to induce clinically-relevant acute toxicity (small bowel V15Gy: 138-cc IMRT versus 157-cc 3DCRT; p = 0.005). We found that the IMRT treatment volumes were typically larger than that covered by classic bony landmark-derived fields, without incurring penalty with respect to adjacent organs-at-risk. For rectal carcinoma, IMRT, compared to 3DCRT, yielded plans superior with respect to target coverage, homogeneity, and conformality, while lowering dose to adjacent organs-at-risk. This is achieved despite treating larger volumes, raising the possibility of a clinically-relevant improvement in the therapeutic ratio through the use of IMRT with a belly-board apparatus.

  5. Traditional Galactagogue Foods and Their Connection to Human Milk Volume in Thai Breastfeeding Mothers.

    PubMed

    Buntuchai, Ganokwun; Pavadhgul, Patcharanee; Kittipichai, Wirin; Satheannoppakao, Warapone

    2017-08-01

    Thai traditional galactagogue consumption is still observed today. However, there are few scientific studies that describe this practice. Research aim: The aim of this study was to describe the connection between traditional galactagogue consumption and human milk volume. Self-reported maternal surveys ( N = 36) were conducted of mothers and their infants who breastfeed exclusively. The mothers were interviewed about traditional galactagogue consumption and intake of protein-rich foods using a semiquantitative food-frequency questionnaire. They were also assessed for energy and nutrient intake using the 24-hr dietary recall method. Their infants were between 1 and 3 months of age and were test weighed for 24 hr to measure their mother's own milk volume. Partial correlation was used to test the relationship between galactagogue consumption and milk volume by controlling the infants' birth weight, weight-for-age, maternal energy, and carbohydrate intake. The results revealed that consumption of some traditional galactagogues was significantly correlated to human milk volume, including banana flower, lemon basil, Thai basil, bottle gourd, and pumpkin ( p < .05). Furthermore, there were significant correlations between consumption of some kinds of protein and milk volume, including egg tofu, chicken, fish, and seafood ( p < .05). Maternal energy and carbohydrate intake were related to milk volume ( p < .05), but protein intake was not. Certain kinds of traditional galactagogues and proteins are associated with human milk volume. However, studies related to the active ingredients in these galactagogues are required to secure a recommendation about use of traditional galactagogues among breastfeeding mothers.

  6. Integrated Vehicle and Trajectory Design of Small Spacecraft with Electric Propulsion for Earth and Interplanetary Missions

    NASA Technical Reports Server (NTRS)

    Spangelo, Sara; Dalle, Derek; Longmier, Benjamin

    2015-01-01

    This paper investigates the feasibility of Earth-transfer and interplanetary mission architectures for miniaturized spacecraft using emerging small solar electric propulsion technologies. Emerging small SEP thrusters offer significant advantages relative to existing technologies and will enable U-class systems to perform trajectory maneuvers with significant Delta V requirements. The approach in this paper is unique because it integrates trajectory design with vehicle sizing and accounts for the system and operational constraints of small U-class missions. The modeling framework includes integrated propulsion, orbit, energy, and external environment dynamics and systems-level power, energy, mass, and volume constraints. The trajectory simulation environment models orbit boosts in Earth orbit and flyby and capture trajectories to interplanetary destinations. A family of small spacecraft mission architectures are studied, including altitude and inclination transfers in Earth orbit and trajectories that escape Earth orbit and travel to interplanetary destinations such as Mercury, Venus, and Mars. Results are presented visually to show the trade-offs between competing performance objectives such as maximizing available mass and volume for payloads and minimizing transfer time. The results demonstrate the feasibility of using small spacecraft to perform significant Earth and interplanetary orbit transfers in less than one year with reasonable U-class mass, power, volume, and mission durations.

  7. Does surgeon volume matter in the outcome of endoscopic inguinal hernia repair?

    PubMed

    Köckerling, F; Bittner, R; Kraft, B; Hukauf, M; Kuthe, A; Schug-Pass, C

    2017-02-01

    For open and endoscopic inguinal hernia surgery, it has been demonstrated that low-volume surgeons with fewer than 25 and 30 procedures, respectively, per year are associated with significantly more recurrences than high-volume surgeons with 25 and 30 or more procedures, respectively, per year. This paper now explores the relationship between the caseload and the outcome based on the data from the Herniamed Registry. The prospective data of patients in the Herniamed Registry were analyzed using the inclusion criteria minimum age of 16 years, male patient, primary unilateral inguinal hernia, TEP or TAPP techniques and availability of data on 1-year follow-up. In total, 16,290 patients were enrolled between September 1, 2009, and February 1, 2014. Of the participating surgeons, 466 (87.6 %) had carried out fewer than 25 endoscopic/laparoscopic operations (low-volume surgeons) and 66 (12.4 %) surgeons 25 or more operations (high-volume surgeons) per year. Univariable (1.03 vs. 0.73 %; p = 0.047) and multivariable analysis [OR 1.494 (1.065-2.115); p = 0.023] revealed that low-volume surgeons had a significantly higher recurrence rate compared with the high-volume surgeons, although that difference was small. Multivariable analysis also showed that pain on exertion was negatively affected by a lower caseload <25 [OR 1.191 (1.062-1.337); p = 0.003]. While here, too, the difference was small, the fact that in that group there was a greater proportion of patients with small hernia defect sizes may have also played a role since the risk in that group was higher. In this analysis, no evidence was found that pain at rest [OR 1.052 (0.903-1.226); p = 0.516] or chronic pain requiring treatment [OR 1.108 (0.903-1.361); p = 0.326] were influenced by the surgeon volume. As confirmed by previously published studies, the data in the Herniamed Registry also demonstrated that the endoscopic/laparoscopic inguinal hernia surgery caseload impacted the outcome. However, given the overall high-quality level the differences between a "low-volume" surgeon and a "high-volume" surgeon were small. That was due to the use of a standardized technique, structured training as well as continuous supervision of trainees and surgeons with low annual caseload.

  8. Lecture Notes on Human Anatomy. Part Two, Fourth Edition.

    ERIC Educational Resources Information Center

    Conrey, Kathleen

    During the process of studying the specific course content of human anatomy, students are being educated to expand their vocabulary, deal successfully with complex tasks, and learn a specific way of thinking. This is the second volume in a set of notes which are designed to accompany a lecture series in human anatomy. This volume includes…

  9. Lecture Notes on Human Anatomy. Part One, Fourth Edition.

    ERIC Educational Resources Information Center

    Conrey, Kathleen

    During the process of studying the specific course content of human anatomy, students are being educated to expand their vocabulary, deal successfully with complex tasks, and use a specific way of thinking. This is the first volume in a set of notes which are designed to accompany a lecture series in human anatomy. This volume includes discussions…

  10. Stage-dependent remodeling of the nuclear envelope and lamina during rabbit early embryonic development.

    PubMed

    Popken, Jens; Schmid, Volker J; Strauss, Axel; Guengoer, Tuna; Wolf, Eckhard; Zakhartchenko, Valeri

    2016-04-22

    Utilizing 3D structured illumination microscopy, we investigated the quality and quantity of nuclear invaginations and the distribution of nuclear pores during rabbit early embryonic development and identified the exact time point of nucleoporin 153 (NUP153) association with chromatin during mitosis. Contrary to bovine early embryonic nuclei, featuring almost exclusively nuclear invaginations containing a small volume of cytoplasm, nuclei in rabbit early embryonic stages show additionally numerous invaginations containing a large volume of cytoplasm. Small-volume invaginations frequently emanated from large-volume nuclear invaginations but not vice versa, indicating a different underlying mechanism. Large- and small-volume nuclear envelope invaginations required the presence of chromatin, as they were restricted to chromatin-positive areas. The chromatin-free contact areas between nucleolar precursor bodies (NPBs) and large-volume invaginations were free of nuclear pores. Small-volume invaginations were not in contact with NPBs. The number of invaginations and isolated intranuclear vesicles per nucleus peaked at the 4-cell stage. At this stage, the nuclear surface showed highly concentrated clusters of nuclear pores surrounded by areas free of nuclear pores. Isolated intranuclear lamina vesicles were usually NUP153 negative. Cytoplasmic, randomly distributed NUP153-positive clusters were highly abundant at the zygote stage and decreased in number until they were almost absent at the 8-cell stage and later. These large NUP153 clusters may represent a maternally provided NUP153 deposit, but they were not visible as clusters during mitosis. Major genome activation at the 8- to 16-cell stage may mark the switch from a necessity for a deposit to on-demand production. NUP153 association with chromatin is initiated during metaphase before the initiation of the regeneration of the lamina. To our knowledge, the present study demonstrates for the first time major remodeling of the nuclear envelope and its underlying lamina during rabbit preimplantation development.

  11. Small intracerebral hemorrhages have a low spot sign prevalence and are less likely to expand.

    PubMed

    Dowlatshahi, Dar; Yogendrakumar, Vignan; Aviv, Richard I; Rodriguez-Luna, David; Molina, Carlos A; Silva, Yolanda; Dzialowski, Imanuel; Czlonkowska, Anna; Boulanger, Jean-Martin; Lum, Cheemun; Gubitz, Gord; Padma, Vasantha; Roy, Jayanta; Kase, Carlos S; Bhatia, Rohit; Hill, Michael D; Demchuk, Andrew M

    2016-02-01

    Hematoma expansion is a major predictor of morbidity and mortality after intracerebral hemorrhage (ICH). Both baseline hematoma volume and the CT-angiogram (CTA) spot sign predict hematoma expansion. Because the CTA spot sign may represent foci of active hemorrhage, we hypothesized that patients with smaller baseline hematoma volumes are less likely to be spot sign positive, and therefore less likely to expand. We sought to validate our prior finding that small hematomas are unlikely to expand, and to determine the relationship between baseline hematoma volume, spot sign status, and risk of hematoma expansion. Data were from the prospective PREDICT ICH study. Patients presenting within 6 h of symptom onset with completed baseline CT, CTA, and follow-up CT were included. Baseline hematoma volume was categorized a priori (<3 mL, 3-10 mL, 10-20 mL, >20 mL). The primary outcome was significant hematoma expansion (≥6 mL, ≥12.5 mL or ≥33%) and secondary outcomes were early neurological worsening, good clinical outcome (modified Rankin Scale 0-3), and mortality at 90 days. Among 315 patients meeting the inclusion criteria, baseline hematoma volume category predicted absolute hematoma expansion (p < 0.001), spot sign prevalence (p < 0.001), early neurologic worsening (p = 0.002), clinical outcome (p < 0.001), and mortality (p < 0.001). Very small hematomas (<3 mL) were unlikely to be spot positive (7.7%), unlikely to expand (2.6%), and were associated with a 73% chance of good clinical outcome. Spot sign appeared to be most predictive of expansion in the 3-10 mL baseline hematoma volume category. Very small hematomas are unlikely to expand and have a low spot sign prevalence. Hemostatic therapy trials may be best targeted at hemorrhages >3 mL in volume. © 2016 World Stroke Organization.

  12. Change of the human taste bud volume over time.

    PubMed

    Srur, Ehab; Stachs, Oliver; Guthoff, Rudolf; Witt, Martin; Pau, Hans Wilhelm; Just, Tino

    2010-08-01

    The specific aim of this study is to measure the taste volume in healthy human subjects over a 2.5-month period and to demonstrate morphological changes of the peripheral taste organs. Eighteen human taste buds in four fungiform papillae (fPap) were examined over a 10-week period. The fungiform papillae investigated were selected based on the form of the papillae or the arrangement of surface taste pores. Measurements were performed over 10 consecutive weeks, with five scans in a day once a week. The following parameters were measured: height and diameter of the taste bud, diameter of the fungiform papilla and diameter of the taste pore. The findings of this exploratory study indicated that (1) taste bud volumes changed over a 10-week period, (2) the interval between two volume maxima within the 10-week period was 3-5 weeks, and (3) the diameter of the fPap did not correlate with the volume of a single taste bud or with the volume of all taste buds in the fPap within the 10-week period. This exploratory in vivo study revealed changes in taste bud volumes in healthy humans with age-related gustatory sensitivity. These findings need to be considered when studying the effect of denervation of fungiform papillae in vivo using confocal microscopy. Crown Copyright 2009. Published by Elsevier Ireland Ltd. All rights reserved.

  13. Determination of loss tangent of human tear film at 9.8 GHz

    NASA Astrophysics Data System (ADS)

    Bansal, Namita; Dhaliwal, A. S.; Mann, K. S.

    2015-08-01

    Basal (non-stimulated) tears that are produced by accessory lacrimal glands located in conjunctiva of human eye, form tear film which in turn keeps the eye moist and lubricate; nourishes the eye; protects the eye from dust, bacterial infection and shear forces generated during eye movements and blinking; and provides a refractive surface on the corneal epithelium. Film is known to contain water, mucin, lipids, lysozyme, glucose, urea, sodium etc. In present communication, loss tangent of human tear film has been determined at 9.8 GHz microwaves by employing cavity perturbation technique at a temperature of 37°C. The basal tears from a small population comprising six subjects were collected and average value of loss tangent is reported. Slater's technique was used to reduce the error caused in measuring the volume of sample. The determined values are useful to study the biological effects of microwaves on tear film as well as other parts of human eye such as eye lens and lens epithelial cells. To the best of author's knowledge, no such study is available in literature at any radio as well as microwave frequencies; therefore present determinations are first of its kind.

  14. Monocyte Subset Dynamics in Human Atherosclerosis Can Be Profiled with Magnetic Nano-Sensors

    PubMed Central

    Wildgruber, Moritz; Lee, Hakho; Chudnovskiy, Aleksey; Yoon, Tae-Jong; Etzrodt, Martin; Pittet, Mikael J.; Nahrendorf, Matthias; Croce, Kevin; Libby, Peter; Weissleder, Ralph; Swirski, Filip K.

    2009-01-01

    Monocytes are circulating macrophage and dendritic cell precursors that populate healthy and diseased tissue. In humans, monocytes consist of at least two subsets whose proportions in the blood fluctuate in response to coronary artery disease, sepsis, and viral infection. Animal studies have shown that specific shifts in the monocyte subset repertoire either exacerbate or attenuate disease, suggesting a role for monocyte subsets as biomarkers and therapeutic targets. Assays are therefore needed that can selectively and rapidly enumerate monocytes and their subsets. This study shows that two major human monocyte subsets express similar levels of the receptor for macrophage colony stimulating factor (MCSFR) but differ in their phagocytic capacity. We exploit these properties and custom-engineer magnetic nanoparticles for ex vivo sensing of monocytes and their subsets. We present a two-dimensional enumerative mathematical model that simultaneously reports number and proportion of monocyte subsets in a small volume of human blood. Using a recently described diagnostic magnetic resonance (DMR) chip with 1 µl sample size and high throughput capabilities, we then show that application of the model accurately quantifies subset fluctuations that occur in patients with atherosclerosis. PMID:19461894

  15. KSC Tech Transfer News, Volume 4, No. 2

    NASA Technical Reports Server (NTRS)

    Dunn, Carol (Editor)

    2011-01-01

    There is a strong focus on technology in our human exploration strategy and a focus on a wide range of technology readiness levels (TRLs) across all NASA missions - from low-TRL development of innovative technological concepts that help reposition NASA on the cutting edge, to infusion of technology to solve critical mission needs. Throughout the TRL spectrum, there is a major emphasis on partnerships with academia, industry, and other Government agencies and among NASA Centers. This edition features are: (1) Aluminum Foam Heat Exchanger for Cold Helium Production, (2) Launching a Small Business with NASA Shuttle Software, (4) Aviation Technologies and the Personal Cabin Pressurization Monitor, (5) Granular Mechanics and Regolith Laboratory, (6) The Leahy-Smith America Invents Act

  16. Head ballistocardiogram based on wireless multi-location sensors.

    PubMed

    Onizuka, Kohei; Sodini, Charles G

    2015-08-01

    Recently a wearable BCG monitoring technique based on an accelerometer worn at the ear was demonstrated to replace a conventional bulky BCG acquisition system. In this work, a multi-location wireless vital signs monitor was developed, and at least two common acceleration vectors correlating to sitting-BCG were found in the supine position by using head PPG signal as a reference for eight healthy human subjects. The head side amplitude in the supine position is roughly proportional to the sitting amplitude that is in turn proportional to the stroke volume. Signal processing techniques to identify J-waves in a subject having small amplitude was also developed based on the two common vectors at the head side and top.

  17. Timber in Missouri, 1972.

    Treesearch

    John S. Jr. Spencer; Burton L. Essex

    1976-01-01

    The third inventory of Missouri's timber resource shows a small gain in growing-stock volume and a somewhat larger gain in sawtimber volume since 1959. Area of commercial forest declined sharply between surveys. Presented are text and statistics on forest area and timber volume, growth, mortality, ownership, stocking, future timber supply, and forest management...

  18. Long noncoding RNA SNHG1 promotes non-small cell lung cancer progression by up-regulating MTDH via sponging miR-145-5p.

    PubMed

    Lu, Qingchun; Shan, Shan; Li, Yanyan; Zhu, Dongyi; Jin, Wenjing; Ren, Tao

    2018-02-21

    Long noncoding RNAs participate in the progression and initiation of non-small cell lung cancer (NSCLC), although the mechanism remains unknown. The lncRNA identified as small nucleolar RNA host gene 1 ( SNHG1) is a novel lncRNA that is increased in multiple human cancers; however, the regulatory mechanism requires further investigation. In this study, we discovered that SNHG1 was markedly up-regulated in NSCLC tissues and cells and that SNHG1 silencing decreased tumor volumes. Moreover, we explored its regulatory mechanism and found that SNHG1 directly bound to microRNA (miRNA)-145-5p, isolating miR-145-5p from its target gene MTDH. Inhibition of SNHG1 suppressed NSCLC cell viability, proliferation, migration, and invasion in vitro, but its effect was rescued by miR-145-5p inhibition. These results demonstrate that SNHG1 contributes to NSCLC progression by modulating the miR-145-5p/ MTDH axis, and it could potentially be a therapeutic target as well as a diagnostic marker.-Lu, Q., Shan, S., Li, Y., Zhu, D., Jin, W., Ren, T. Long noncoding RNA SNHG1 promotes non-small cell lung cancer progression by up-regulating MTDH via sponging miR-145-5p.

  19. On-Chip Spyhole Nanoelectrospray Ionization Mass Spectrometry for Sensitive Biomarker Detection in Small Volumes

    NASA Astrophysics Data System (ADS)

    Zhong, Xiaoqin; Qiao, Liang; Stauffer, Géraldine; Liu, Baohong; Girault, Hubert H.

    2018-03-01

    A polyimide microfluidic chip with a microhole emitter (Ø 10-12 μm) created on top of a microchannel by scanning laser ablation has been designed for nanoelectrospray ionization (spyhole-nanoESI) to couple microfluidics with mass spectrometry. The spyhole-nanoESI showed higher sensitivity compared to standard ESI and microESI from the end of the microchannel. The limits of detection (LOD) for peptide with the spyhole-nanoESI MS reached 50 pM, which was 600 times lower than that with standard ESI. The present microchip emitter allows the analysis of small volumes of samples. As an example, a small cell lung cancer biomarker, neuron-specific enolase (NSE), was detected by monitoring the transition of its unique peptide with the spyhole-nanoESI MS/MS. NSE at 0.2 nM could be well identified with a signal to noise ratio (S/N) of 50, and thereby its LOD was estimated to be 12 pM. The potential application of the spyhole-nanoESI MS/MS in cancer diagnosis was further demonstrated with the successful detection of 2 nM NSE from 1 μL of human serum. Before the detection, the serum sample spiked with NSE was first depleted with immune spin column, then desalted by centrifugal filter device, and finally digested by trypsin, without any other complicated preparation steps. The concentration matched the real condition of clinical samples. In addition, the microchips can be disposable to avoid any cross contamination. The present technique provides a highly efficient way to couple microfluidics with MS, which brings additional values to various microfluidics and MS-based analysis.

  20. Space Flight Human System Standards (SFHSS). Volume 2; Human Factors, Habitability and Environmental Factors" and Human Integration Design Handbook (HIDH)

    NASA Technical Reports Server (NTRS)

    Davis, Jeffrey R.; Fitts, David J.

    2009-01-01

    This viewgraph presentation reviews the standards for space flight hardware based on human capabilities and limitations. The contents include: 1) Scope; 2) Applicable documents; 3) General; 4) Human Physical Characteristics and Capabilities; 5) Human Performance and Cognition; 6) Natural and Induced Environments; 7) Habitability Functions; 8) Architecture; 9) Hardware and Equipment; 10) Crew Interfaces; 11) Spacesuits; 12) Operatons: Reserved; 13) Ground Maintenance and Assembly: Reserved; 14) Appendix A-Reference Documents; 15) Appendix N-Acronyms and 16) Appendix C-Definition. Volume 2 is supported by the Human Integration Design Handbook (HIDH)s.

  1. The Accuracy and Precision of Flow Measurements Using Phase Contrast Techniques

    NASA Astrophysics Data System (ADS)

    Tang, Chao

    Quantitative volume flow rate measurements using the magnetic resonance imaging technique are studied in this dissertation because the volume flow rates have a special interest in the blood supply of the human body. The method of quantitative volume flow rate measurements is based on the phase contrast technique, which assumes a linear relationship between the phase and flow velocity of spins. By measuring the phase shift of nuclear spins and integrating velocity across the lumen of the vessel, we can determine the volume flow rate. The accuracy and precision of volume flow rate measurements obtained using the phase contrast technique are studied by computer simulations and experiments. The various factors studied include (1) the partial volume effect due to voxel dimensions and slice thickness relative to the vessel dimensions; (2) vessel angulation relative to the imaging plane; (3) intravoxel phase dispersion; (4) flow velocity relative to the magnitude of the flow encoding gradient. The partial volume effect is demonstrated to be the major obstacle to obtaining accurate flow measurements for both laminar and plug flow. Laminar flow can be measured more accurately than plug flow in the same condition. Both the experiment and simulation results for laminar flow show that, to obtain the accuracy of volume flow rate measurements to within 10%, at least 16 voxels are needed to cover the vessel lumen. The accuracy of flow measurements depends strongly on the relative intensity of signal from stationary tissues. A correction method is proposed to compensate for the partial volume effect. The correction method is based on a small phase shift approximation. After the correction, the errors due to the partial volume effect are compensated, allowing more accurate results to be obtained. An automatic program based on the correction method is developed and implemented on a Sun workstation. The correction method is applied to the simulation and experiment results. The results show that the correction significantly reduces the errors due to the partial volume effect. We apply the correction method to the data of in vivo studies. Because the blood flow is not known, the results of correction are tested according to the common knowledge (such as cardiac output) and conservation of flow. For example, the volume of blood flowing to the brain should be equal to the volume of blood flowing from the brain. Our measurement results are very convincing.

  2. Biosphere 2 test module: A ground-based sunlight-driven prototype of a closed ecological life support system

    NASA Astrophysics Data System (ADS)

    Nelson, Mark; Leigh, Linda; Alling, Abigail; MacCallum, Taber; Allen, John; Alvarez-Romo, Norberto

    Constructed in 1986, the Biosphere 2 Test Module has been used since the end of that year for closed ecological systems experiments. It is the largest closed ecological facility ever built, with a sealed variable volume of some 480 cubic meters. It is built with a skin of steel spaceframes with double-laminated glass panels admitting about 65 percent Photosynthetically Active Radiation (PAR). The floor is of welded steel and there is an underground atmospheric connection via an air duct to a variable volume chamber (``lung'') permitting expansion and contraction of the Test Module's air volume caused by changes in temperature and barometric pressure, which causes a slight positive pressure from inside the closed system to the outside thereby insuring that the very small leakage rate is outward. Several series of closed ecological system investigations have been carried out in this facility. One series of experiments investigated the dynamics of higher plants and associated soils with the atmosphere under varying light and temperature conditions. Another series of experiments included one human in the closed system for three, five and twenty-one days. During these experiments the Test Module had subsystems which completely recycled its water and atmosphere; all the human dietary needs were produced within the facility, and all wastes were recycled using a marsh plant/microbe system. Other experiments have examined the capability of individual component systems used, such as the soil bed reactors, to eliminate experimentally introduced trace gases. Analytic systems developed for these experiments include continuous monitors of eleven atmospheric gases in addition to the complete gas chromatography mass spectrometry (GCMS) examinations of potable, waste system and irrigation water quality.

  3. Bladder filling variation during conformal radiotherapy for rectal cancer

    NASA Astrophysics Data System (ADS)

    Sithamparam, S.; Ahmad, R.; Sabarudin, A.; Othman, Z.; Ismail, M.

    2017-05-01

    Conformal radiotherapy for rectal cancer is associated with small bowel toxicity mainly diarrhea. Treating patients with a full bladder is one of the practical solutions to reduce small bowel toxicity. Previous studies on prostate and cervix cancer patients revealed that maintaining consistent bladder volume throughout radiotherapy treatment is challenging. The aim of this study was to measure bladder volume variation throughout radiotherapy treatment. This study also measured the association between bladder volume changes and diarrhea. Twenty two rectal cancer patients were recruited prospectively. Patients were planned for treatment with full bladder following departmental bladder filling protocol and the planning bladder volume was measured during CT-simulation. During radiotherapy, the bladder volume was measured weekly using cone-beam computed tomography (CBCT) and compared to planning bladder volume. Incidence and severity of diarrhea were recorded during the weekly patient review. There was a negative time trend for bladder volume throughout five weeks treatment. The mean bladder volume decreased 18 % from 123 mL (SD 54 mL) during CT-simulation to 101 mL (SD 71 mL) on the 5th week of radiotherapy, but the decrease is not statistically significant. However, there was a large variation of bladder volume within each patient during treatment. This study showed an association between changes of bladder volume and diarrhea (P = 0.045). In conclusion bladder volume reduced throughout radiotherapy treatment for conformal radiotherapy for rectal cancer and there was a large variation of bladder volume within patients.

  4. Quantifying the Release of Biomarkers of Myocardial Necrosis from Cardiac Myocytes and Intact Myocardium.

    PubMed

    Marjot, Jack; Kaier, Thomas E; Martin, Eva D; Reji, Shiney S; Copeland, O'Neal; Iqbal, Mohammed; Goodson, Bob; Hamren, Sarah; Harding, Sian E; Marber, Michael S

    2017-05-01

    Myocardial infarction is diagnosed when biomarkers of cardiac necrosis exceed the 99th centile, although guidelines advocate even lower concentrations for early rule-out. We examined how many myocytes and how much myocardium these concentrations represent. We also examined if dietary troponin can confound the rule-out algorithm. Individual rat cardiac myocytes, rat myocardium, ovine myocardium, or human myocardium were spiked into 400-μL aliquots of human serum. Blood was drawn from a volunteer after ingestion of ovine myocardium. High-sensitivity assays were used to measure cardiac troponin T (cTnT; Roche, Elecsys), cTnI (Abbott, Architect), and cardiac myosin-binding protein C (cMyC; EMD Millipore, Erenna ® ). The cMyC assay could only detect the human protein. For each rat cardiac myocyte added to 400 μL of human serum, cTnT and cTnI increased by 19.0 ng/L (95% CI, 16.8-21.2) and 18.9 ng/L (95% CI, 14.7-23.1), respectively. Under identical conditions cTnT, cTnI, and cMyC increased by 3.9 ng/L (95% CI, 3.6-4.3), 4.3 ng/L (95% CI, 3.8-4.7), and 41.0 ng/L (95% CI, 38.0-44.0) per μg of human myocardium. There was no detectable change in cTnI or cTnT concentration after ingestion of sufficient ovine myocardium to increase cTnT and cTnI to approximately 1 × 10 8 times their lower limits of quantification. Based on pragmatic assumptions regarding cTn and cMyC release efficiency, circulating species, and volume of distribution, 99th centile concentrations may be exceeded by necrosis of 40 mg of myocardium. This volume is much too small to detect by noninvasive imaging. © 2017 American Association for Clinical Chemistry.

  5. Simultaneous determination of multiclass pesticide residues in human plasma using a mini QuEChERS method.

    PubMed

    Srivastava, Anshuman; Rai, Satyajeet; Kumar Sonker, Ashish; Karsauliya, Kajal; Pandey, Chandra Prabha; Singh, Sheelendra Pratap

    2017-06-01

    Blood is one of the most assessable matrices for the determination of pesticide residue exposure in humans. Effective sample preparation/cleanup of biological samples is very important in the development of a sensitive, reproducible, and robust method. In the present study, a simple, cost-effective, and rapid gas chromatography-tandem mass spectrometry method has been developed and validated for simultaneous analysis of 31 multiclass (organophosphates, organochlorines, and synthetic pyrethroids) pesticide residues in human plasma by means of a mini QuEChERS (quick, easy, cheap, effective, rugged, and safe) method. We have adopted a modified version of the QuEChERS method, which is primarily used for pesticide residue analysis in food commodities. The QuEChERS method was optimized by use of different extraction solvents and different amounts and combinations of salts and sorbents (primary-secondary amines and C 18 ) for the dispersive solid-phase extraction step. The results show that a combination of ethyl acetate with 2% acetic acid, magnesium sulfate (0.4 g), and solid-phase extraction for sample cleanup with primary-secondary amines (50 mg) per 1-mL volume of plasma is the most suitable for generating acceptable results with high recoveries for all multiclass pesticides from human plasma. The mean recovery ranged from 74% to 109% for all the analytes. The limit of quantification and limit of detection of the method ranged from 0.12 to 13.53 ng mL -1 and from 0.04 to 4.10 ng mL -1 respectively. The intraday precision and the interday precision of the method were 6% or less and 11% or less respectively. This method would be useful for the analysis of a wide range of pesticides of interest in a small volume of clinical and/or forensic samples to support biomonitoring and toxicological applications. Graphical Abstract Pesticide residues analysis in human plasma using mini QuEChERS method.

  6. Small gray matter volume in orbitofrontal cortex in Prader-Willi syndrome: a voxel-based MRI study.

    PubMed

    Ogura, Kaeko; Fujii, Toshikatsu; Abe, Nobuhito; Hosokai, Yoshiyuki; Shinohara, Mayumi; Takahashi, Shoki; Mori, Etsuro

    2011-07-01

    Prader-Willi syndrome (PWS) is a genetically determined neurodevelopmental disorder presenting with behavioral symptoms including hyperphagia, disinhibition, and compulsive behavior. The behavioral problems in individuals with PWS are strikingly similar to those in patients with frontal pathologies, particularly those affecting the orbitofrontal cortex (OFC). However, neuroanatomical abnormalities in the frontal lobe have not been established in PWS. The aim of this study was to look, using volumetric analysis, for morphological changes in the frontal lobe, especially the OFC, of the brains of individuals with PWS. Twelve adults with PWS and 13 age- and gender-matched control subjects participated in structural magnetic resonance imaging (MRI) scans. The whole-brain images were segmented and normalized to a standard stereotactic space. Regional gray matter volumes were compared between the PWS group and the control group using voxel-based morphometry. The PWS subjects showed small gray-matter volume in several regions, including the OFC, caudate nucleus, inferior temporal gyrus, precentral gyrus, supplementary motor area, postcentral gyrus, and cerebellum. The small gray-matter volume in the OFC remained significant in a separate analysis that included total gray matter volume as a covariate. These preliminary findings suggest that the neurobehavioral symptoms in individuals with PWS are related to structural brain abnormalities in these areas. Copyright © 2010 Wiley-Liss, Inc.

  7. Cubic-Foot Volume Tables for Shortleaf Pine in the Virginia-Carolina Piedmont

    Treesearch

    Glenn P. Haney; Paul P. Kormanik

    1962-01-01

    Available volume tables for shortleaf pine are based on merchantable height and do not show volumes to the small top diameter limits now used in many areas. Volume tables based on total height are also often preferred because they eliminate the error associated with ocular estimates of merchantable height. The table presented here for natural shortleaf pine is based on...

  8. Adipose tissue engineering: state of the art, recent advances and innovative approaches.

    PubMed

    Tanzi, Maria Cristina; Farè, Silvia

    2009-09-01

    Adipose tissue is a highly specialized connective tissue found either in white or brown forms, the white form being the most abundant in adult humans. Loss or damage of white adipose tissue due to aging or pathological conditions needs reconstructive approaches. To date, two main strategies are being investigated for generating functional adipose tissue: autologous tissue/cell transplantation and adipose tissue engineering. Free-fat transplantation rarely achieves sufficient tissue augmentation owing to delayed neovascularization, with subsequent cell necrosis and graft volume shrinkage. Tissue engineering approaches represent, instead, a more suitable alternative for adipose tissue regeneration; they can be performed either with in situ or de novo adipogenesis. In situ adipogenesis or transplantation of encapsulated cells can be useful in healing small-volume defects, whereas restoration of large defects, where vascularization and a rapid volumetric gain are strict requirements, needs de novo strategies with 3D scaffold/filling matrix combinations. For adipose tissue engineering, the use of adult mesenchymal stem cells (both adipose- and bone marrow-derived stem cells) or of preadipocytes is preferred to the use of mature adipocytes, which have low expandability and poor ability for volume retention. This review intends to assemble and describe recent work on this topic, critically presenting successes obtained and drawbacks faced to date.

  9. USEPA MANUAL OF METHODS FOR VIROLOGY | Science ...

    EPA Pesticide Factsheets

    This chapter describes procedures for the detection of coliphases in water matrices. These procedures are based on those presented in the Supplement to the 20th Edition of Standard Methods for the Examination of Water and Eastewater and EPA Methods 1601 and 1602. Two quantitative procedures and one qualitative, presence-absence procedures are presented. The procedures can be used, without supplementary methods, to assay small volumes of water (10 mL to 1L). For larger volumes (>100L), large-scale concentration methods such as described in Chapter 14 may be incorporated into the assay scheme. However, as some concentration procedures may result in appreciable loss or inactivation of coliphage, it is recommended that the suitability of any large volume concentration method be evaluated in measured recovery trials before implementation. Develop sensitive techniques to detect and identify emerging human waterborne pathogenic viruses and viruses on the CCL.Determine effectiveness of viral indicators to measure microbial quality in water matrices.Support activities: (a) culture and distribution of mammalian cells for Agency and scientific community research needs, (b) provide operator expertise for research requiring confocal and electron microscopy, (c) glassware cleaning, sterilization and biological waste disposal for the Cincinnati EPA facility, (d) operation of infectious pathogenic suite, (e) maintenance of walk-in constant temperature rooms and (f) provid

  10. Multi-Component Molecular-Level Body Composition Reference Methods: Evolving Concepts and Future Directions

    PubMed Central

    Heymsfield, Steven B.; Ebbeling, Cara B.; Zheng, Jolene; Pietrobelli, Angelo; Strauss, Boyd J.; Silva, Analiza M.; Ludwig, David S.

    2015-01-01

    Excess adiposity is the main phenotypic feature that defines human obesity and that plays a pathophysiological role in most chronic diseases. Measuring the amount of fat mass present is thus a central aspect of studying obesity at the individual and population levels. Nevertheless, a consensus is lacking among investigators on a single accepted “reference” approach for quantifying fat mass in vivo. While the research community generally relies on the multicomponent body-volume class of “reference” models for quantifying fat mass, no definable guide discerns among different applied equations for partitioning the four (fat, water, protein, and mineral mass) or more quantified components, standardizes “adjustment” or measurement system approaches for model-required labeled water dilution volumes and bone mineral mass estimates, or firmly establishes the body temperature at which model physical properties are assumed. The resulting differing reference strategies for quantifying body composition in vivo leads to small but under some circumstances important differences in the amount of measured body fat. Recent technological advances highlight opportunities to expand model applications to new subject groups and measured components such as total body protein. The current report reviews the historical evolution of multicomponent body volume-based methods in the context of prevailing uncertainties and future potential. PMID:25645009

  11. Standardizing the Delivery of 20 μL of Hapten During Patch Testing.

    PubMed

    Selvick, Annika; Stauss, Kari; Strobush, Katrina; Taylor, Lauren; Picard, Alexandra; Doll, Andrea; Reeder, Margo

    2016-01-01

    The current method for patch test tray assembly requires hand dispensing a small volume of hapten onto chambers. Because of human error, this technique produces inaccurate and inconsistent results. The recommended volume of hapten for patch testing using Finn Chambers is 20 μL. The aims of this study were to create a device that standardizes the delivery of 20 μL and to compare it with the current hand dispensing technique. A device, named the Revolution, was created using the SolidWorks program. Five nurses in our Contact Dermatitis Clinic were asked to load 10 Finn Chambers using the current technique and also using the Revolution. Assembly time, volume of petrolatum, and accuracy of placement were measured. After the 3 trials, the nurses completed a survey on the 2 methods. The amount of petrolatum dispensed using the current technique ranged from 16 to 85 μL, with an average amount of 41.39 μL. The Revolution design dispensed an average of 19.78 μL. The current hand dispensing technique does not allow for accurate and consistent dispensing of 20 μL for patch testing. In contrast, the Revolution is an accurate and consistent device that can help standardize the patch testing method.

  12. Rational design of an on-site volume reduction system for source-separated urine.

    PubMed

    Pahore, Muhammad Masoom; Ito, Ryusei; Funamizu, Naoyuki

    2010-04-01

    Human urine contains nitrogen, phosphorus and potassium, which can be applied as fertilizer in agriculture, replacing commercial fertilizer. However, owing to the low nutrient content of the urine, huge quantities must be transported to farmland to meet the nutrient demand of crops. This highly increases the transportation cost for the farmers. To address the transportation issue, a new on-site volume reduction system was tested at the laboratory scale based on water evaporation from vertical gauze sheets. A mathematical water transport model was proposed to evaluate the performance of the system. The mass transfer coefficient and the resistance of water flow through the sheet in the water transport model were obtained from the experiments. The results agreed with the simulated data, thereby confirming the proposed model. The model was then applied to the dry climate of southern Pakistan, having an air temperature of 30-40 degrees C and air humidity of 20-40%, for an 80% volume reduction of 10 L urine per day, which corresponds to a family of 10 members (average for a household in Pakistan). The findings revealed that the estimated size of the vertical sheet is 440-2060 cm2, which is only a small area for setting up the system at a household level.

  13. Black Swift Technologies LLC

    NASA Technical Reports Server (NTRS)

    DiNardo, Anne Marie

    2016-01-01

    Colorado-based Black Swift Technologies (BST) created a small unmanned aircraft system(sUAS) to help NASA get a clearer picture of soil moisture through the Small Business Innovation Research (SBIR) program. Soil moisture is defined in terms of volume of water per unit volume of soil. Using BSTs sUAS, NASA scientists can gather ground truth measurements for a clearer observation by getting closer to the source. This can help rule out misleading results generated by satellite imagery.

  14. Radiation Dose-Volume Effects in the Stomach and Small Bowel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kavanagh, Brian D., E-mail: Brian.Kavanagh@ucdenver.ed; Pan, Charlie C.; Dawson, Laura A.

    2010-03-01

    Published data suggest that the risk of moderately severe (>=Grade 3) radiation-induced acute small-bowel toxicity can be predicted with a threshold model whereby for a given dose level, D, if the volume receiving that dose or greater (VD) exceeds a threshold quantity, the risk of toxicity escalates. Estimates of VD depend on the means of structure segmenting (e.g., V15 = 120 cc if individual bowel loops are outlined or V45 = 195 cc if entire peritoneal potential space of bowel is outlined). A similar predictive model of acute toxicity is not available for stomach. Late small-bowel/stomach toxicity is likely relatedmore » to maximum dose and/or volume threshold parameters qualitatively similar to those related to acute toxicity risk. Concurrent chemotherapy has been associated with a higher risk of acute toxicity, and a history of abdominal surgery has been associated with a higher risk of late toxicity.« less

  15. Low-Dead-Volume Inlet for Vacuum Chamber

    NASA Technical Reports Server (NTRS)

    Naylor, Guy; Arkin, C.

    2010-01-01

    Gas introduction from near-ambient pressures to high vacuum traditionally is accomplished either by multi-stage differential pumping that allows for very rapid response, or by a capillary method that allows for a simple, single-stage introduction, but which often has a delayed response. Another means to introduce the gas sample is to use the multi-stage design with only a single stage. This is accomplished by using a very small conductance limit. The problem with this method is that a small conductance limit will amplify issues associated with dead -volume. As a result, a high -vacuum gas inlet was developed with low dead -volume, allowing the use of a very low conductance limit interface. Gas flows through the ConFlat flange at a relatively high flow rate at orders of magnitude greater than through the conductance limit. The small flow goes through a conductance limit that is a double-sided ConFlat.

  16. Low-Dead-Volume Inlet for Vacuum Chamber

    NASA Technical Reports Server (NTRS)

    Naylor, Guy; Arkin, C.

    2011-01-01

    Gas introduction from near-ambient pressures to high vacuum traditionally is accomplished either by multi-stage differential pumping that allows for very rapid response, or by a capillary method that allows for a simple, single-stage introduction, but which often has a delayed response. Another means to introduce the gas sample is to use the multi-stage design with only a single stage. This is accomplished by using a very small conductance limit. The problem with this method is that a small conductance limit will amplify issues associated with dead-volume. As a result, a high-vacuum gas inlet was developed with low dead-volume, allowing the use of a very low conductance limit interface. Gas flows through the ConFlat flange at a relatively high flow rate at orders of magnitude greater than through the conductance limit. The small flow goes through a conductance limit that is a double-sided ConFlat.

  17. Space station crew safety alternatives study. Volume 3: Safety impact of human factors

    NASA Technical Reports Server (NTRS)

    Rockoff, L. A.; Raasch, R. F.; Peercy, R. L., Jr.

    1985-01-01

    The first 15 years of accumulated space station concepts for Initial Operational Capability (IOC) during the early 1990's was considered. Twenty-five threats to the space station are identified and selected threats addressed as impacting safety criteria, escape and rescue, and human factors safety concerns. Of the 25 threats identified, eight are discussed including strategy options for threat control: fire, biological or toxic contamination, injury/illness, explosion, loss of pressurization, radiation, meteoroid penetration and debris. Of particular interest here is volume three (of five volumes) pertaining to the safety impact of human factors.

  18. Overdrinking, swallowing inhibition, and regional brain responses prior to swallowing

    PubMed Central

    Saker, Pascal; Egan, Gary F.; McKinley, Michael J.; Denton, Derek A.

    2016-01-01

    In humans, drinking replenishes fluid loss and satiates the sensation of thirst that accompanies dehydration. Typically, the volume of water drunk in response to thirst matches the deficit. Exactly how this accurate metering is achieved is unknown; recent evidence implicates swallowing inhibition as a potential factor. Using fMRI, this study investigated whether swallowing inhibition is present after more water has been drunk than is necessary to restore fluid balance within the body. This proposal was tested using ratings of swallowing effort and measuring regional brain responses as participants prepared to swallow small volumes of liquid while they were thirsty and after they had overdrunk. Effort ratings provided unequivocal support for swallowing inhibition, with a threefold increase in effort after overdrinking, whereas addition of 8% (wt/vol) sucrose to water had minimal effect on effort before or after overdrinking. Regional brain responses when participants prepared to swallow showed increases in the motor cortex, prefrontal cortices, posterior parietal cortex, striatum, and thalamus after overdrinking, relative to thirst. Ratings of swallowing effort were correlated with activity in the right prefrontal cortex and pontine regions in the brainstem; no brain regions showed correlated activity with pleasantness ratings. These findings are all consistent with the presence of swallowing inhibition after excess water has been drunk. We conclude that swallowing inhibition is an important mechanism in the overall regulation of fluid intake in humans. PMID:27791015

  19. User Interactive Software for Analysis of Human Physiological Data

    NASA Technical Reports Server (NTRS)

    Cowings, Patricia S.; Toscano, William; Taylor, Bruce C.; Acharya, Soumydipta

    2006-01-01

    Ambulatory physiological monitoring has been used to study human health and performance in space and in a variety of Earth-based environments (e.g., military aircraft, armored vehicles, small groups in isolation, and patients). Large, multi-channel data files are typically recorded in these environments, and these files often require the removal of contaminated data prior to processing and analyses. Physiological data processing can now be performed with user-friendly, interactive software developed by the Ames Psychophysiology Research Laboratory. This software, which runs on a Windows platform, contains various signal-processing routines for both time- and frequency- domain data analyses (e.g., peak detection, differentiation and integration, digital filtering, adaptive thresholds, Fast Fourier Transform power spectrum, auto-correlation, etc.). Data acquired with any ambulatory monitoring system that provides text or binary file format are easily imported to the processing software. The application provides a graphical user interface where one can manually select and correct data artifacts utilizing linear and zero interpolation and adding trigger points for missed peaks. Block and moving average routines are also provided for data reduction. Processed data in numeric and graphic format can be exported to Excel. This software, PostProc (for post-processing) requires the Dadisp engineering spreadsheet (DSP Development Corp), or equivalent, for implementation. Specific processing routines were written for electrocardiography, electroencephalography, electromyography, blood pressure, skin conductance level, impedance cardiography (cardiac output, stroke volume, thoracic fluid volume), temperature, and respiration

  20. Cryopreservation of Human Mucosal Leukocytes.

    PubMed

    Hughes, Sean M; Shu, Zhiquan; Levy, Claire N; Ferre, April L; Hartig, Heather; Fang, Cifeng; Lentz, Gretchen; Fialkow, Michael; Kirby, Anna C; Adams Waldorf, Kristina M; Veazey, Ronald S; Germann, Anja; von Briesen, Hagen; McElrath, M Juliana; Dezzutti, Charlene S; Sinclair, Elizabeth; Baker, Chris A R; Shacklett, Barbara L; Gao, Dayong; Hladik, Florian

    2016-01-01

    Understanding how leukocytes in the cervicovaginal and colorectal mucosae respond to pathogens, and how medical interventions affect these responses, is important for developing better tools to prevent HIV and other sexually transmitted infections. An effective cryopreservation protocol for these cells following their isolation will make studying them more feasible. To find an optimal cryopreservation protocol for mucosal mononuclear leukocytes, we compared cryopreservation media and procedures using human vaginal leukocytes and confirmed our results with endocervical and colorectal leukocytes. Specifically, we measured the recovery of viable vaginal T cells and macrophages after cryopreservation with different cryopreservation media and handling procedures. We found several cryopreservation media that led to recoveries above 75%. Limiting the number and volume of washes increased the fraction of cells recovered by 10-15%, possibly due to the small cell numbers in mucosal samples. We confirmed that our cryopreservation protocol also works well for both endocervical and colorectal leukocytes. Cryopreserved leukocytes had slightly increased cytokine responses to antigenic stimulation relative to the same cells tested fresh. Additionally, we tested whether it is better to cryopreserve endocervical cells on the cytobrush or in suspension. Leukocytes from cervicovaginal and colorectal tissues can be cryopreserved with good recovery of functional, viable cells using several different cryopreservation media. The number and volume of washes has an experimentally meaningful effect on the percentage of cells recovered. We provide a detailed, step-by-step protocol with best practices for cryopreservation of mucosal leukocytes.

  1. Structure and Dynamics of Bimodal Colloidal Dispersions in a Low-Molecular-Weight Polymer Solution

    DOE PAGES

    Zhang, Fan; Allen, Andrew J.; Levine, Lyle E.; ...

    2017-02-24

    We present an experimental study of the structural and dynamical properties of bimodal, micrometersized colloidal dispersions (size ratio ≈ 2) in an aqueous solution of low-molecular weight polymer (polyethylene glycol 2000) using synchrotron ultra-small angle X-ray scattering (USAXS) and USAXSbased X-ray photon correlation spectroscopy. We fixed the volume fraction of the large particles at 5 % and systematically increased the volume fraction of the small particles from 0 % to 5 % to evaluate its effect on the structure and dynamics. The bimodal dispersions were homogenous through the investigated parameter space. We found that the partial structure factors can bemore » satisfactorily retrieved for the bimodal colloidal dispersions using a Percus-Yevick hard sphere potential when the particle size distributions of the particles were taken into account. We also found that the partial structure factor between the large particles does not exhibit significant variation with increasing volume fraction of small particles, whereas the isothermal compressibility of the binary mixture was found to decrease with increasing volume fraction of small particles. The dynamics of single-component large particle dispersion obey the principles of de Gennes narrowing, where the wave vector dependence of the interparticle diffusion coefficient is inversely proportional to the interparticle structure factor. The dynamics of the bimodal dispersions demonstrate strong dependence on the fraction of small particles. As a result, we also made a comparison between the experimental effective dynamic viscosity of the bimodal dispersion with theoretical predictions, which suggest that the complex mutual interactions between large and small particles have a strong effect on the dynamic behaviors of bimodal dispersions.« less

  2. Structure and Dynamics of Bimodal Colloidal Dispersions in a Low-Molecular-Weight Polymer Solution.

    PubMed

    Zhang, Fan; Allen, Andrew J; Levine, Lyle E; Tsai, De-Hao; Ilavsky, Jan

    2017-03-21

    We present an experimental study of the structural and dynamical properties of bimodal, micrometer-sized colloidal dispersions (size ratio ≈ 2) in an aqueous solution of low-molecular-weight polymer (polyethylene glycol 2000) using synchrotron ultra-small angle X-ray scattering (USAXS) and USAXS-based X-ray photon correlation spectroscopy. We fixed the volume fraction of the large particles at 5% and systematically increased the volume fraction of the small particles from 0 to 5% to evaluate their effects on the structure and dynamics. The bimodal dispersions were homogenous through the investigated parameter space. We found that the partial structure factors can be satisfactorily retrieved for the bimodal colloidal dispersions using a Percus-Yevick hard-sphere potential when the size distributions of the particles were taken into account. We also found that the partial structure factor between the large particles did not exhibit a significant variation with increasing volume fraction of the small particles, whereas the isothermal compressibility of the binary mixture was found to decrease with increasing volume fraction of the small particles. The dynamics of single-component large-particle dispersion obey the principles of de Gennes narrowing, where the wave vector dependence of the interparticle diffusion coefficient is inversely proportional to the interparticle structure factor. The dynamics of the bimodal dispersions demonstrate a strong dependence on the fraction of small particles. We also made a comparison between the experimental effective dynamic viscosity of the bimodal dispersion with the theoretical predictions, which suggest that the complex mutual interactions between the large and small particles have a strong effect on the dynamic behaviors of bimodal dispersions.

  3. The usefulness of oncoplastic volume displacement techniques in the superiorly located breast cancers for Korean patients with small to moderate-sized breasts.

    PubMed

    Yang, Jung Dug; Bae, Sung Gun; Chung, Ho Yun; Cho, Byung Chae; Park, Ho Yong; Jung, Jin Hyang

    2011-11-01

    Because the average breast size of Korean women is not as large as that of western women, it is not so easy to apply the oncoplastic volume displacement technique. However, we have tried to use volume displacement techniques that work well with small-breasted women. In this study, we report the usefulness of displacement techniques in the superiorly located cancers with small- to moderate-sized breasts. Between September 2006 and August 2009, 58 women were treated for superiorly located cancers. All patients who were selected had small- to moderate-sized breasts and small to moderate breast defects. They were divided into 3 groups. The groups were split based on the distance from the nipple-areolar complex, which are as follows: near, intermediate, and far. Their mean age was 46 and the average follow-up interval was 21 months. Median weight of the specimen on the tumor side was 84 g (range, 29-140 g). The various surgical techniques used were the "round block" technique (n = 8) and "batwing mastopexy" (n = 4) for near lesions; "tennis racket" method (n = 32) and "rotational flap" (n = 8) for intermediate lesions; and "parallelogram mastopexy lumpectomy" (n = 6) for far lesions. There were 4 complications (nipple-areolar complex partial necrosis, radiation burn, and 2 wound dehiscence). No local recurrences have been observed and a majority of the patients were satisfied with cosmetic results. Oncoplastic volume displacement techniques in superiorly located breast cancers for Korean patients with small- to moderate-sized breast are reliable and should be considered in the case of breast conserving surgery (BCS).

  4. Structure and Dynamics of Bimodal Colloidal Dispersions in a Low-Molecular-Weight Polymer Solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Fan; Allen, Andrew J.; Levine, Lyle E.

    We present an experimental study of the structural and dynamical properties of bimodal, micrometersized colloidal dispersions (size ratio ≈ 2) in an aqueous solution of low-molecular weight polymer (polyethylene glycol 2000) using synchrotron ultra-small angle X-ray scattering (USAXS) and USAXSbased X-ray photon correlation spectroscopy. We fixed the volume fraction of the large particles at 5 % and systematically increased the volume fraction of the small particles from 0 % to 5 % to evaluate its effect on the structure and dynamics. The bimodal dispersions were homogenous through the investigated parameter space. We found that the partial structure factors can bemore » satisfactorily retrieved for the bimodal colloidal dispersions using a Percus-Yevick hard sphere potential when the particle size distributions of the particles were taken into account. We also found that the partial structure factor between the large particles does not exhibit significant variation with increasing volume fraction of small particles, whereas the isothermal compressibility of the binary mixture was found to decrease with increasing volume fraction of small particles. The dynamics of single-component large particle dispersion obey the principles of de Gennes narrowing, where the wave vector dependence of the interparticle diffusion coefficient is inversely proportional to the interparticle structure factor. The dynamics of the bimodal dispersions demonstrate strong dependence on the fraction of small particles. As a result, we also made a comparison between the experimental effective dynamic viscosity of the bimodal dispersion with theoretical predictions, which suggest that the complex mutual interactions between large and small particles have a strong effect on the dynamic behaviors of bimodal dispersions.« less

  5. Academy of Human Resource Development Conference Proceedings (Raleigh-Durham, North Carolina, March 8-12, 2000).

    ERIC Educational Resources Information Center

    Kuchinke, K. Peter, Ed.

    This two-volume document contains the proceedings of the 2000 conference of the Academy of Human Resource Development (AHRD). Volume 1 contains the following materials: conference overview; text of a town forum on social responsibility and human resource development (HRD); papers from symposia 1-24; and papers from innovative sessions 1-4. The…

  6. Teaching about the Holocaust and Genocide: Introduction. The Human Rights Series, Volume I.

    ERIC Educational Resources Information Center

    Adams, Clayton; And Others

    Designed to assist secondary school social studies, English, and humanities teachers as they teach about the Nazi Holocaust, the first of two volumes serves as an introduction to the concept of human rights. Divided into a rationale and two units, each unit includes a statement of purpose, a list of objectives, and a group of learning activities…

  7. Ground-Based Phase of Spaceflight Experiment "Biosignal" Using Autonomic Microflurimeter "Fluor-K"

    NASA Astrophysics Data System (ADS)

    Grigorieva, O. V.; Gal'chuk, S. V.; Rudimov, E. G.; Buravkova, L. B.

    2013-02-01

    The majority of flight experiments with the use of cell cultures and equipment like KUBIK and CRIOGEM carried out on board of the satellites (Bion, Foton) and ISS only allows the after-flight biosamples to be analyzed. As far as with few exceptions, the real-time cellular parameters registration for a long period is hard to be implemented. We developed the "Fluor-K" equipment - precision, small-sized, autonomous, two-channel, programmed fluorimeter. This device is designed for registration of differential fluorescent signal from organic and non-organic objects of microscale in small volumes (cellular organelles suspensions, animal and human cells, unicellular algae, bacteria, various fluorescent colloid solutions). Beside that, "Fluor-K" allows simultaneous detection of temperature. The ground-based tests of the device proved successful. The developed software can support experimental schedules while real-time data registration with the built-in storage device allows changes in selected parameters to be analyzed using wide range of fluorescent probes.

  8. Sex differences and the impact of steroid hormones on the developing human brain.

    PubMed

    Neufang, Susanne; Specht, Karsten; Hausmann, Markus; Güntürkün, Onur; Herpertz-Dahlmann, Beate; Fink, Gereon R; Konrad, Kerstin

    2009-02-01

    Little is known about the hormonal effects of puberty on the anatomy of the developing human brain. In a voxel-based morphometry study, sex-related differences in gray matter (GM) volume were examined in 46 subjects aged 8-15 years. Males had larger GM volumes in the left amygdala, whereas females had larger right striatal and bilateral hippocampal GM volumes than males. Sexually dimorphic areas were related to Tanner stages (TS) of pubertal development and to circulating level of steroid hormones in a subsample of 30 subjects. Regardless of sex, amygdala and hippocampal volumes varied as a function of TS and were associated with circulating testosterone (TEST) levels. By contrast, striatal GM volumes were unrelated to pubertal development and circulating steroid hormones. Whole-brain regression analyses revealed positive associations between circulating estrogen levels and parahippocampal GM volumes as well as between TEST levels and diencephalic brain structures. In addition, a negative association was found between circulating TEST and left parietal GM volumes. These data suggest that GM development in certain brain regions is associated with sexual maturation and that pubertal hormones might have organizational effects on the developing human brain.

  9. The State of Small Business: A Report of the President. Together with the Annual Report on Small Business and Competition of the Small Business Administration.

    ERIC Educational Resources Information Center

    Executive Office of the President, Washington, DC.

    This volume consists of a report of the President concerning the state of small businesses as well as the U.S. Small Business Administration annual report on small business and competition. Addressed in the President's report are the following issues: the role of small business in the economy; the foundations of small business policy; and problems…

  10. Human Factors, Habitability and Environmental Health and the Human Integration Design Handbook. Volume 2

    NASA Technical Reports Server (NTRS)

    Houbec, Keith; Tillman, Barry; Connolly, Janis

    2010-01-01

    For decades, Space Life Sciences and NASA as an Agency have considered NASA-STD-3000, Man-Systems Integration Standards, a significant contribution to human spaceflight programs and to human-systems integration in general. The document has been referenced in numerous design standards both within NASA and by organizations throughout the world. With research program and project results being realized, advances in technology and new information in a variety of topic areas now available, the time arrived to update this extensive suite of requirements and design information. During the past several years, a multi-NASA center effort has been underway to write the update to NASA-STD-3000 with standards and design guidance that would be applicable to all future human spaceflight programs. NASA-STD-3001 - Volumes 1 and 2 - and the Human Integration Design Handbook (HIDH) were created. Volume 1, Crew Health, establishes NASA s spaceflight crew health standards for the pre-flight, in-flight, and post-flight phases of human spaceflight. Volume 2, Human Factors, Habitability and Environmental Health, focuses on the requirements of human-system integration and how the human crew interacts with other systems, and how the human and the system function together to accomplish the tasks for mission success. The HIDH is a compendium of human spaceflight history and knowledge, and provides useful background information and research findings. And as the HIDH is a stand-alone companion to the Standards, the maintenance of the document has been streamlined. This unique and flexible approach ensures that the content is current and addresses the fundamental advances of human performance and human capabilities and constraints research. Current work focuses on the development of new sections of Volume 2 and collecting updates to the HIDH. The new sections in development expand the scope of the standard and address mission operations and support operations. This effort is again collaboration with representatives from the Johnson Space Center Missions Operations and Space Life Sciences Directorates and the Engineering Directorate from Kennedy Space Center as well as discipline experts from across the Agency.

  11. 14 CFR 1204.402 - Responsibilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Business Policy § 1204.402 Responsibilities. (a) Office of Small and Disadvantaged Business Utilization (OSDBU). The Associate Administrator for Small and Disadvantaged Business Utilization, NASA Headquarters... Installation considers that the volume of procurement at the Installation does not warrant a full-time Small...

  12. 14 CFR 1204.402 - Responsibilities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Business Policy § 1204.402 Responsibilities. (a) Office of Small and Disadvantaged Business Utilization (OSDBU). The Associate Administrator for Small and Disadvantaged Business Utilization, NASA Headquarters... Installation considers that the volume of procurement at the Installation does not warrant a full-time Small...

  13. Mathematical modelling of tumour volume dynamics in response to stereotactic ablative radiotherapy for non-small cell lung cancer

    NASA Astrophysics Data System (ADS)

    Tariq, Imran; Humbert-Vidan, Laia; Chen, Tao; South, Christopher P.; Ezhil, Veni; Kirkby, Norman F.; Jena, Rajesh; Nisbet, Andrew

    2015-05-01

    This paper reports a modelling study of tumour volume dynamics in response to stereotactic ablative radiotherapy (SABR). The main objective was to develop a model that is adequate to describe tumour volume change measured during SABR, and at the same time is not excessively complex as lacking support from clinical data. To this end, various modelling options were explored, and a rigorous statistical method, the Akaike information criterion, was used to help determine a trade-off between model accuracy and complexity. The models were calibrated to the data from 11 non-small cell lung cancer patients treated with SABR. The results showed that it is feasible to model the tumour volume dynamics during SABR, opening up the potential for using such models in a clinical environment in the future.

  14. Bistability: Requirements on Cell-Volume, Protein Diffusion, and Thermodynamics

    PubMed Central

    Endres, Robert G.

    2015-01-01

    Bistability is considered wide-spread among bacteria and eukaryotic cells, useful e.g. for enzyme induction, bet hedging, and epigenetic switching. However, this phenomenon has mostly been described with deterministic dynamic or well-mixed stochastic models. Here, we map known biological bistable systems onto the well-characterized biochemical Schlögl model, using analytical calculations and stochastic spatiotemporal simulations. In addition to network architecture and strong thermodynamic driving away from equilibrium, we show that bistability requires fine-tuning towards small cell volumes (or compartments) and fast protein diffusion (well mixing). Bistability is thus fragile and hence may be restricted to small bacteria and eukaryotic nuclei, with switching triggered by volume changes during the cell cycle. For large volumes, single cells generally loose their ability for bistable switching and instead undergo a first-order phase transition. PMID:25874711

  15. SU-E-J-266: Cone Beam Computed Tomography (CBCT) Inter-Scan and Inter-Observer Tumor Volume Variability Assessment in Patients Treated with Stereotactic Body Radiation Therapy (SBRT) for Early Stage Non-Small Cell Lung Cancer (NSCLC)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hou, Y; Aileen, C; Kozono, D

    Purpose: Quantification of volume changes on CBCT during SBRT for NSCLC may provide a useful radiological marker for radiation response and adaptive treatment planning, but the reproducibility of CBCT volume delineation is a concern. This study is to quantify inter-scan/inter-observer variability in tumor volume delineation on CBCT. Methods: Twenty earlystage (stage I and II) NSCLC patients were included in this analysis. All patients were treated with SBRT with a median dose of 54 Gy in 3 to 5 fractions. Two physicians independently manually contoured the primary gross tumor volume on CBCTs taken immediately before SBRT treatment (Pre) and after themore » same SBRT treatment (Post). Absolute volume differences (AVD) were calculated between the Pre and Post CBCTs for a given treatment to quantify inter-scan variability, and then between the two observers for a given CBCT to quantify inter-observer variability. AVD was also normalized with respect to average volume to obtain relative volume differences (RVD). Bland-Altman approach was used to evaluate variability. All statistics were calculated with SAS version 9.4. Results: The 95% limit of agreement (mean ± 2SD) on AVD and RVD measurements between Pre and Post scans were −0.32cc to 0.32cc and −0.5% to 0.5% versus −1.9 cc to 1.8 cc and −15.9% to 15.3% for the two observers respectively. The 95% limit of agreement of AVD and RVD between the two observers were −3.3 cc to 2.3 cc and −42.4% to 28.2% respectively. The greatest variability in inter-scan RVD was observed with very small tumors (< 5 cc). Conclusion: Inter-scan variability in RVD is greatest with small tumors. Inter-observer variability was larger than inter-scan variability. The 95% limit of agreement for inter-observer and inter-scan variability (∼15–30%) helps define a threshold for clinically meaningful change in tumor volume to assess SBRT response, with larger thresholds needed for very small tumors. Part of the work was funded by a Kaye award; Disclosure/Conflict of interest: Raymond H. Mak: Stock ownership: Celgene, Inc. Consulting: Boehringer-Ingelheim, Inc.« less

  16. Tri-level study of the causes of traffic accidents, volume 2 : special analyses.

    DOT National Transportation Integrated Search

    1979-05-01

    This final report is comprised of two volumes. Volume I provides causal result tabulations and related analyses. Volume II presents several special analysis reports dealing with driver vision knowledge, psychological make-up, etc. Human, environmenta...

  17. Human nasal polyp microenvironments maintained in a viable and functional state as xenografts in NOD-scid IL2rgamma(null) mice.

    PubMed

    Bernstein, Joel M; Brooks, Stephen P; Lehman, Heather K; Pope, Liza; Sands, Amy; Shultz, Leonard D; Bankert, Richard B

    2009-12-01

    The objective was to develop a model with which to study the cellular and molecular events associated with nasal polyp progression. To accomplish this, we undertook to develop a system in which nondisrupted human nasal polyp tissue could be successfully implanted into severely immunocompromised mice, in which the histopathology of the original nasal polyp tissue, including inflammatory lymphocytes, epithelial and goblet cell hyperplasia, and subepithelial fibrosis, could be preserved for prolonged periods. Small, non-disrupted pieces of human nasal polyp tissues were subcutaneously implanted into NOD-scid IL2rgamma(null) mice. Xenografts at 8 to 12 weeks after implantation were examined histologically and immunohistochemically to identify human inflammatory leukocytes and to determine whether the characteristic histopathologic characteristics of the nasal polyps were maintained for a prolonged period. The xenografts, spleen, lung, liver, and kidneys were examined histologically and immunohistochemically and were evaluated for changes in volume. The sera of these mice were assayed for human cytokines and immunoglobulin. Xenografts of human nasal polyp tissues were established after their subcutaneous implantation into NOD-scid IL2rgamma(null) mice. The xenografts were maintained in a viable and functional state for up to 3 months, and retained a histopathologic appearance similar to that of the original tissue, with a noticeable increase in goblet cell hyperplasia and marked mucus accumulation in the submucosal glands compared to the original nasal polyp tissue. Inflammatory lymphocytes present in the polyp microenvironment were predominantly human CD8+ T cells with an effector memory phenotype. Human CD4+ T cells, CD138+ plasma cells, and CD68+ macrophages were also observed in the xenografts. Human immunoglobulin and interferon-gamma were detected in the sera of xenograft-bearing mice. The polyp-associated lymphocytes proliferated and were found to migrate from the xenografts to the spleens of the recipient mice, resulting in a significant splenomegaly. A progressive increase in the volume of the xenografts was observed with little or no evidence of mouse cell infiltration into the human leukocyte antigen-positive human tissue. An average twofold increase in polyp volume was found at 3 months after engraftment. The use of innate and adaptive immunodeficient NOD-scid mice homozygous for targeted mutations in the interleukin-2 receptor gamma-chain locus NOD-scid IL2rgamma(null) for establishing xenografts of nondisrupted pieces of human nasal polyp tissues represents a significant improvement over the previously reported xenograft model that used partially immunoincompetent CB17-scid mice as tissue recipients. The absence of the interleukin-2 receptor gamma-chain results in complete elimination of natural killer cell development, as well as severe impairments in T and B cell development. These mice, lacking both innate and adaptive immune responses, significantly improve upon the long-term engraftment of human nasal polyp tissues and provide a model with which to study how nasal polyp-associated lymphocytes and their secreted biologically active products contribute to the histopathology and progression of this chronic inflammatory disease.

  18. Red Blood Cell Passage of Small Capillaries Is Associated with Transient Ca2+-mediated Adaptations.

    PubMed

    Danielczok, Jens G; Terriac, Emmanuel; Hertz, Laura; Petkova-Kirova, Polina; Lautenschläger, Franziska; Laschke, Matthias W; Kaestner, Lars

    2017-01-01

    When red blood cells (RBCs) pass constrictions or small capillaries they need to pass apertures falling well below their own cross section size. We used different means of mechanical stimulations (hypoosmotic swelling, local mechanical stimulation, passing through microfluidic constrictions) to observe cellular responses of human RBCs in terms of intracellular Ca 2+ -signaling by confocal microscopy of Fluo-4 loaded RBCs. We were able to confirm our in vitro results in a mouse dorsal skinfold chamber model showing a transiently increased intracellular Ca 2+ when RBCs were passing through small capillaries in vivo . Furthermore, we performed the above-mentioned in vitro experiments as well as measurements of RBCs filterability under various pharmacological manipulations (GsMTx-4, TRAM-34) to explore the molecular mechanism of the Ca 2+ -signaling. Based on these experiments we conclude that mechanical stimulation of RBCs activates mechano-sensitive channels most likely Piezo1. This channel activity allows Ca 2+ to enter the cell, leading to a transient activation of the Gardos-channel associated with K + , Cl - , and water loss, i.e., with a transient volume adaptation facilitating the passage of the RBCs through the constriction.

  19. Red Blood Cell Passage of Small Capillaries Is Associated with Transient Ca2+-mediated Adaptations

    PubMed Central

    Danielczok, Jens G.; Terriac, Emmanuel; Hertz, Laura; Petkova-Kirova, Polina; Lautenschläger, Franziska; Laschke, Matthias W.; Kaestner, Lars

    2017-01-01

    When red blood cells (RBCs) pass constrictions or small capillaries they need to pass apertures falling well below their own cross section size. We used different means of mechanical stimulations (hypoosmotic swelling, local mechanical stimulation, passing through microfluidic constrictions) to observe cellular responses of human RBCs in terms of intracellular Ca2+-signaling by confocal microscopy of Fluo-4 loaded RBCs. We were able to confirm our in vitro results in a mouse dorsal skinfold chamber model showing a transiently increased intracellular Ca2+ when RBCs were passing through small capillaries in vivo. Furthermore, we performed the above-mentioned in vitro experiments as well as measurements of RBCs filterability under various pharmacological manipulations (GsMTx-4, TRAM-34) to explore the molecular mechanism of the Ca2+-signaling. Based on these experiments we conclude that mechanical stimulation of RBCs activates mechano-sensitive channels most likely Piezo1. This channel activity allows Ca2+ to enter the cell, leading to a transient activation of the Gardos-channel associated with K+, Cl−, and water loss, i.e., with a transient volume adaptation facilitating the passage of the RBCs through the constriction. PMID:29259557

  20. Plasmid profiling of bacterial isolates from confined environments

    NASA Astrophysics Data System (ADS)

    van Houdt, Rob; Provoost, Ann; Coninx, Ilse; Leys, Natalie; Mergeay, Max

    Plasmid profiling of bacterial isolates from confined environments R. Van Houdt, I. Coninx, A. Provoost, N. Leys, and M. Mergeay Expertise group for Molecular and Cellular Biology, Institute for Environment, Health and Safety, Belgian Nuclear Research Centre (SCK•CEN), Boeretang 200, B-2400 Mol, Belgium. Human exploration of extreme and isolated hostile environments such as space requires special confined small volume habitats to protect and house the crew. However, human confinement in such small volume habitats has restrictions on waste disposal and personal hygiene and inevitably generates a particular community of microorganisms within the habitat. These microorganisms are mainly originating from the crew (skin, mucous membranes, upper respiratory tract, mouth, and gastrointestinal tract) but also include the residing environmental microorganisms. Earth-based confined habitats such as the Antarctic Research Station Concordia are used as test beds for long-duration spaceflights to study the physiologic and psychological adaptation to isolated environments. The dynamics of the environmental microbial population in such a test bed could render additional insights in assessing the potential health risks in long-duration space missions. Not only total bacterial contamination levels are important, but it is essential to identify also the predominant microbial taxa and their mobile genetic elements (MGE). These MGEs could be exchanged between bacteria by horizontal gene transfer and may alter the pathogenic potential since they often carry antibiotic resistance or more in general adaptation-enhancing traits. In this study several bacterial strains isolated in the Concordia research station were examined for their plasmid content. An optimized protocol for extraction of large plasmids showed the present of at least one plasmid in 50% of the strains. For all strains the minimal inhibitory concentration of a range of antibiotics was determined indicating resistance to different classes of antibiotics including aminoglycosides, penicillins, macrolides and chloramphenicol. Whether these antibiotic resistance determinants are plasmid-bound and whether these traits can be transferred to other bacteria is under investigation.

  1. Towards Universal Screening for Toxoplasmosis: Rapid, Cost-effective and Simultaneous Detection of Toxoplasma Anti-IgG, IgM and IgA Antibodies Using Very Small Serum Volumes

    EPA Pesticide Factsheets

    No dataset associated with this publication.This dataset is associated with the following publication:Augustine, S. Towards Universal Screening for Toxoplasmosis: Rapid, Cost-effective and Simultaneous Detection of Toxoplasma Anti-IgG, IgM and IgA Antibodies Using Very Small Serum Volumes. JOURNAL OF CLINICAL MICROBIOLOGY. American Society for Microbiology, Washington, DC, USA, 56(7): 1-2, (2016).

  2. Volume change measurements of rice by environmental scanning electron microscopy and stereoscopy.

    PubMed

    Tang, Xiaohu; De Rooij, Mario; De Jong, Liesbeth

    2007-01-01

    The measurement of volume change, which is induced by changing the relative humidity, is performed on rice by using environmental scanning electron microscope (ESEM) and stereoscopy techniques. The typical DeltaV% approximately RH curve of rice in both sorption and desorption can be categorized into three regions: low, intermediate, and high dependence on relative humidity from low- to high-relative humidity. The volume changes faster for rice samples with lower crystallinity, which is because the amorphous component is easier to absorb moisture than the crystalline component. The volume change behavior in various relative humidity environments is comparable with rice isotherm curve in sorption process though discrepancies exist in desorption, which are thought to be the presence of small pores and microstructure changes at high relative humidity. The volume in the desorption branch is less than that in the sorption branch at the same relative humidity, which can be attributed to the collapse of interior structures, existence of small pores, surface topography loss, and amylose leach.

  3. How Small Is a Billionth?

    ERIC Educational Resources Information Center

    Gough, John

    2007-01-01

    Children's natural curiosity about numbers, big and small can lead to exploring place-value ideas. But how can these abstract concepts be experienced more concretely? This article presents some practical approaches for conceptualising very small numbers using linear models, area models, volume models, and diagrams.

  4. Decrease in cortisol reverses human hippocampal atrophy following treatment of Cushing's disease.

    PubMed

    Starkman, M N; Giordani, B; Gebarski, S S; Berent, S; Schork, M A; Schteingart, D E

    1999-12-15

    Decreased hippocampal volume is observed in patients with Cushing's syndrome and other conditions associated with elevated cortisol levels, stress, or both. Reversibility of hippocampal neuronal atrophy resulting from stress occurs in animals. Our study investigated the potential for reversibility of human hippocampal atrophy. The study included 22 patients with Cushing's disease. Magnetic resonance brain imaging was performed prior to transsphenoidal microadenomectomy and again after treatment. Following treatment, hippocampal formation volume (HFV) increased by up to 10%. The mean percent change (3.2 +/- 2.5) was significantly greater (p < .04) than that of the comparison structure, caudate head volume (1.5 +/- 3.4). Increase in HFV was significantly associated with magnitude of decrease in urinary free cortisol (r = -.61, p < .01). This relationship strengthened after adjustments for age, duration of disease, and months elapsed since surgery (r = -.70, p < .001). There was no significant correlation between caudate head volume change and magnitude of cortisol decrease. Changes in human HFV associated with sustained hypercortisolemia are reversible, at least in part, once cortisol levels decrease. While many brain regions are likely affected by hypercortisolemia, the human hippocampus exhibits increased sensitivity to cortisol, affecting both volume loss and recovery.

  5. Validation of deformable image registration algorithms on CT images of ex vivo porcine bladders with fiducial markers.

    PubMed

    Wognum, S; Heethuis, S E; Rosario, T; Hoogeman, M S; Bel, A

    2014-07-01

    The spatial accuracy of deformable image registration (DIR) is important in the implementation of image guided adaptive radiotherapy techniques for cancer in the pelvic region. Validation of algorithms is best performed on phantoms with fiducial markers undergoing controlled large deformations. Excised porcine bladders, exhibiting similar filling and voiding behavior as human bladders, provide such an environment. The aim of this study was to determine the spatial accuracy of different DIR algorithms on CT images of ex vivo porcine bladders with radiopaque fiducial markers applied to the outer surface, for a range of bladder volumes, using various accuracy metrics. Five excised porcine bladders with a grid of 30-40 radiopaque fiducial markers attached to the outer wall were suspended inside a water-filled phantom. The bladder was filled with a controlled amount of water with added contrast medium for a range of filling volumes (100-400 ml in steps of 50 ml) using a luer lock syringe, and CT scans were acquired at each filling volume. DIR was performed for each data set, with the 100 ml bladder as the reference image. Six intensity-based algorithms (optical flow or demons-based) implemented in theMATLAB platform DIRART, a b-spline algorithm implemented in the commercial software package VelocityAI, and a structure-based algorithm (Symmetric Thin Plate Spline Robust Point Matching) were validated, using adequate parameter settings according to values previously published. The resulting deformation vector field from each registration was applied to the contoured bladder structures and to the marker coordinates for spatial error calculation. The quality of the algorithms was assessed by comparing the different error metrics across the different algorithms, and by comparing the effect of deformation magnitude (bladder volume difference) per algorithm, using the Independent Samples Kruskal-Wallis test. The authors found good structure accuracy without dependency on bladder volume difference for all but one algorithm, and with the best result for the structure-based algorithm. Spatial accuracy as assessed from marker errors was disappointing for all algorithms, especially for large volume differences, implying that the deformations described by the registration did not represent anatomically correct deformations. The structure-based algorithm performed the best in terms of marker error for the large volume difference (100-400 ml). In general, for the small volume difference (100-150 ml) the algorithms performed relatively similarly. The structure-based algorithm exhibited the best balance in performance between small and large volume differences, and among the intensity-based algorithms, the algorithm implemented in VelocityAI exhibited the best balance. Validation of multiple DIR algorithms on a novel physiological bladder phantom revealed that the structure accuracy was good for most algorithms, but that the spatial accuracy as assessed from markers was low for all algorithms, especially for large deformations. Hence, many of the available algorithms exhibit sufficient accuracy for contour propagation purposes, but possibly not for accurate dose accumulation.

  6. Environmental design implications for two deep space SmallSats

    NASA Astrophysics Data System (ADS)

    Kahn, Peter; Imken, Travis; Elliott, John; Sherwood, Brent; Frick, Andreas; Sheldon, Douglas; Lunine, Jonathan

    2017-10-01

    The extreme environmental challenges of deep space exploration force unique solutions to small satellite design in order to enable their use as scientifically viable spacecraft. The challenges of implementing small satellites within limited resources can be daunting when faced with radiation effects on delicate electronics that require shielding or unique adaptations for protection, or mass, power and volume limitations due to constraints placed by the carrier spacecraft, or even Planetary Protection compliant design techniques that drive assembly and testing. This paper will explore two concept studies where the environmental constraints and/or planetary protection mitigations drove the design of the Flight System. The paper will describe the key technical drivers on the Sylph mission concept to explore a plume at Europa as a secondary free-flyer as a part of the planned Europa Mission. Sylph is a radiation-hardened smallsat concept that would utilize terrain relative navigation to fly at low altitudes through a plume, if found, and relay the mass spectra data back through the flyby spacecraft during its 24-h mission. The second topic to be discussed will be the mission design constraints of the Near Earth Asteroid (NEA) Scout concept. NEAScout is a 6U cubesat that would utilize an 86 sq. m solar sail as propulsion to execute a flyby with a near-Earth asteroid and help retire Strategic Knowledge Gaps for future human exploration. NEAScout would cruise for 24 months to reach and characterize one Near-Earth asteroid that is representative of Human Exploration targets and telemeter that data directly back to Earth at the end of its roughly 2.5 year mission.

  7. Effect of mannitol on globe and orbital volumes in humans.

    PubMed

    Weber, Adam C; Blandford, Alexander D; Costin, Bryan R; Perry, Julian D

    2018-03-01

    To determine the effect of intravenous mannitol on globe and orbital volumes. Retrospective chart review of a consecutive series of Cleveland Clinic Neurosurgical Intensive Care Unit patients who underwent computed tomographic imaging before and after intravenous mannitol administration. Volume measurements were performed according to a previously described technique by averaging axial image areas. Measurements before and after mannitol administration were compared using paired t-test. Fourteen patients (28 eyes) met inclusion criteria. Average globe volume decreased 186 mm 3 (-2.5%, p = 0.02) after mannitol administration, while average orbital volume increased 353 mm 3 (+3.5%, p = 0.04). Average globe volume change for subjects with follow-up scan less than 4.7 hours (mean 1.9 hours; range 0.2-4.5 hours) after mannitol administration was -125 mm 3 (-1.7%, p = 0.24) and average orbital volume change was +458 mm 3 (+5.1%, p = 0.11). Average globe volume change after mannitol administration for those with follow-up more than 4.7 hours (average 13.9 hours, range 4.9-24.7 hours) was -246 mm 3 (-3.3%, p = 0.05) and orbital volume change was +248 mm 3 (+2.2%, p = 0.24). Dividing the study population into groups based on mannitol dose did not yield any statistically significant change. Human globe volume decreases after intravenous mannitol administration, while orbital volume increases. These volume changes occur during the time period when intraocular pressure normalizes, after the pressure-lowering effects of the drug. This novel volumetric information improves our understanding of mannitol's mechanism of action and its effects on human ocular and periocular tissues.

  8. A study of unsteady physiological magneto-fluid flow and heat transfer through a finite length channel by peristaltic pumping.

    PubMed

    Tripathi, Dharmendra; Bég, O Anwar

    2012-08-01

    Magnetohydrodynamic peristaltic flows arise in controlled magnetic drug targeting, hybrid haemodynamic pumps and biomagnetic phenomena interacting with the human digestive system. Motivated by the objective of improving an understanding of the complex fluid dynamics in such flows, we consider in the present article the transient magneto-fluid flow and heat transfer through a finite length channel by peristaltic pumping. Reynolds number is small enough and the wavelength to diameter ratio is large enough to negate inertial effects. Analytical solutions for temperature field, axial velocity, transverse velocity, pressure gradient, local wall shear stress, volume flowrate and averaged volume flowrate are obtained. The effects of the transverse magnetic field, Grashof number and thermal conductivity on the flow patterns induced by peristaltic waves (sinusoidal propagation along the length of channel) are studied using graphical plots. The present study identifies that greater pressure is required to propel the magneto-fluid by peristaltic pumping in comparison to a non-conducting Newtonian fluid, whereas, a lower pressure is required if heat transfer is effective. The analytical solutions further provide an important benchmark for future numerical simulations.

  9. Reversal of papilloma growth in rabbits therapeutically vaccinated against E6 with naked DNA and/or vesicular stomatitis virus vectors

    PubMed Central

    Brandsma, Janet L.; Shlyankevich, Mark; Su, Yuhua; Zelterman, Daniel; Rose, John K.; Buonocore, Linda

    2009-01-01

    Persistent infection with high-risk human papillomaviruses (HPVs) is the greatest risk factor for the development of HPV-associated cancers. In this study rabbits bearing persistent and potentially malignant papillomas were used to test the efficacy of vaccination with a recombinant DNA and/or vesicular stomatitis virus (VSV) targeting the cottontail rabbit papillomavirus (CRPV) E6 protein. Immune responses were primed with either vector and boosted twice with the homologous or heterologous E6 vector. Over the course of 18 weeks, E6 vaccination reduced papilloma volumes to one third the volume in the controls, and the rabbits boosted with an heterologous vector tended to mount stronger responses. Small and medium-sized papillomas responded significantly but only slightly better than large papillomas. Finally the initial papilloma burden per rabbit, ranging from <100 mm3 to >1000 mm3, was not prognostic of antitumor efficacy. In summary both E6 vaccines elicited significant therapeutic immunity, and their sequential use tended to be advantageous. PMID:19615481

  10. Space station architectural elements model study

    NASA Technical Reports Server (NTRS)

    Taylor, T. C.; Spencer, J. S.; Rocha, C. J.; Kahn, E.; Cliffton, E.; Carr, C.

    1987-01-01

    The worksphere, a user controlled computer workstation enclosure, was expanded in scope to an engineering workstation suitable for use on the Space Station as a crewmember desk in orbit. The concept was also explored as a module control station capable of enclosing enough equipment to control the station from each module. The concept has commercial potential for the Space Station and surface workstation applications. The central triangular beam interior configuration was expanded and refined to seven different beam configurations. These included triangular on center, triangular off center, square, hexagonal small, hexagonal medium, hexagonal large and the H beam. Each was explored with some considerations as to the utilities and a suggested evaluation factor methodology was presented. Scale models of each concept were made. The models were helpful in researching the seven beam configurations and determining the negative residual (unused) volume of each configuration. A flexible hardware evaluation factor concept is proposed which could be helpful in evaluating interior space volumes from a human factors point of view. A magnetic version with all the graphics is available from the author or the technical monitor.

  11. Computational Studies of Drug Release, Transport and Absorption in the Human Intestines

    NASA Astrophysics Data System (ADS)

    Behafarid, Farhad; Brasseur, J. G.; Vijayakumar, G.; Jayaraman, B.; Wang, Y.

    2016-11-01

    Following disintegration of a drug tablet, a cloud of particles 10-200 μm in diameter enters the small intestine where drug molecules are absorbed into the blood. Drug release rate depends on particle size, solubility and hydrodynamic enhancements driven by gut motility. To quantify the interrelationships among dissolution, transport and wall permeability, we apply lattice Boltzmann method to simulate the drug concentration field in the 3D gut released from polydisperse distributions of drug particles in the "fasting" vs. "fed" motility states. Generalized boundary conditions allow for both solubility and gut wall permeability to be systematically varied. We apply a local 'quasi-steady state' approximation for drug dissolution using a mathematical model generalized for hydrodynamic enhancements and heterogeneity in drug release rate. We observe fundamental differences resulting from the interplay among release, transport and absorption in relationship to particle size distribution, luminal volume, motility, solubility and permeability. For example, whereas smaller volume encourages higher bulk concentrations and reduced release rate, it also encourages higher absorption rate, making it difficult to generalize predictions. Supported by FDA.

  12. AUTOMATED CELL SEGMENTATION WITH 3D FLUORESCENCE MICROSCOPY IMAGES.

    PubMed

    Kong, Jun; Wang, Fusheng; Teodoro, George; Liang, Yanhui; Zhu, Yangyang; Tucker-Burden, Carol; Brat, Daniel J

    2015-04-01

    A large number of cell-oriented cancer investigations require an effective and reliable cell segmentation method on three dimensional (3D) fluorescence microscopic images for quantitative analysis of cell biological properties. In this paper, we present a fully automated cell segmentation method that can detect cells from 3D fluorescence microscopic images. Enlightened by fluorescence imaging techniques, we regulated the image gradient field by gradient vector flow (GVF) with interpolated and smoothed data volume, and grouped voxels based on gradient modes identified by tracking GVF field. Adaptive thresholding was then applied to voxels associated with the same gradient mode where voxel intensities were enhanced by a multiscale cell filter. We applied the method to a large volume of 3D fluorescence imaging data of human brain tumor cells with (1) small cell false detection and missing rates for individual cells; and (2) trivial over and under segmentation incidences for clustered cells. Additionally, the concordance of cell morphometry structure between automated and manual segmentation was encouraging. These results suggest a promising 3D cell segmentation method applicable to cancer studies.

  13. Integrated Microbatteries for Implantable Medical Devices

    NASA Technical Reports Server (NTRS)

    Whitacre, Jay; West, William

    2008-01-01

    Integrated microbatteries have been proposed to satisfy an anticipated need for long-life, low-rate primary batteries, having volumes less than 1 mm3, to power electronic circuitry in implantable medical devices. In one contemplated application, such a battery would be incorporated into a tubular hearing-aid device to be installed against an eardrum. This device is based on existing tube structures that have already been approved by the FDA for use in human ears. As shown in the figure, the battery would comprise a single cell at one end of the implantable tube. A small volume of Li-based primary battery cathode material would be compacted and inserted in the tube near one end, followed by a thin porous separator, followed by a pressed powder of a Li-containing alloy. Current-collecting wires would be inserted, with suitably positioned insulators to prevent a short circuit. The battery would contain a liquid electrolyte consisting of a Li-based salt in an appropriate solvent. Hermetic seals would be created by plugging both ends with a waterproof polymer followed by deposition of parylene.

  14. Fiducial migration following small peripheral lung tumor image-guided CyberKnife stereotactic radiosurgery

    NASA Astrophysics Data System (ADS)

    Strulik, Konrad L.; Cho, Min H.; Collins, Brian T.; Khan, Noureen; Banovac, Filip; Slack, Rebecca; Cleary, Kevin

    2008-03-01

    To track respiratory motion during CyberKnife stereotactic radiosurgery in the lung, several (three to five) cylindrical gold fiducials are implanted near the planned target volume (PTV). Since these fiducials remain in the human body after treatment, we hypothesize that tracking fiducial movement over time may correlate with the tumor response to treatment and pulmonary fibrosis, thereby serving as an indicator of treatment success. In this paper, we investigate fiducial migration in 24 patients through examination of computed tomography (CT) volume images at four time points: pre-treatment, three, six, and twelve month post-treatment. We developed a MATLAB based GUI environment to display the images, identify the fiducials, and compute our performance measure. After we semi-automatically segmented and detected fiducial locations in CT images of the same patient over time, we identified them according to their configuration and introduced a relative performance measure (ACD: average center distance) to detect their migration. We found that the migration tended to result in a movement towards the fiducial center of the radiated tissue area (indicating tumor regression) and may potentially be linked to the patient prognosis.

  15. Enrichment of human bone marrow aspirates for low-density mononuclear cells using a haemonetics discontinuous blood cell separator.

    PubMed

    Raijmakers, R; de Witte, T; Koekman, E; Wessels, J; Haanen, C

    1986-01-01

    Isopycnic density floatation centrifugation has been proven to be a suitable technique to enrich bone marrow aspirates for clonogenic cells on a small scale. We have tested a Haemonetics semicontinuous blood cell separator in order to process large volumes of bone marrow with minimal bone marrow manipulation. The efficacy of isopycnic density floatation was tested in a one and a two-step procedure. Both procedures showed a recovery of about 20% of the nucleated cells and 1-2% of the erythrocytes. The enrichment of clonogenic cells in the one-step procedure appeared superior to the two-step enrichment, first separating buffy coat cells. The recovery of clonogenic cells was 70 and 50%, respectively. Repopulation capacity of the low-density cell fraction containing the clonogenic cells was excellent after autologous reinfusion (6 cases) and allogeneic bone marrow transplantation (3 cases). Fast enrichment of large volumes of bone marrow aspirates with low-density cells containing the clonogenic cells by isopycnic density floatation centrifugation can be done safely using a Haemonetics blood cell separator.

  16. Functional segmentation of dynamic PET studies: Open source implementation and validation of a leader-follower-based algorithm.

    PubMed

    Mateos-Pérez, José María; Soto-Montenegro, María Luisa; Peña-Zalbidea, Santiago; Desco, Manuel; Vaquero, Juan José

    2016-02-01

    We present a novel segmentation algorithm for dynamic PET studies that groups pixels according to the similarity of their time-activity curves. Sixteen mice bearing a human tumor cell line xenograft (CH-157MN) were imaged with three different (68)Ga-DOTA-peptides (DOTANOC, DOTATATE, DOTATOC) using a small animal PET-CT scanner. Regional activities (input function and tumor) were obtained after manual delineation of regions of interest over the image. The algorithm was implemented under the jClustering framework and used to extract the same regional activities as in the manual approach. The volume of distribution in the tumor was computed using the Logan linear method. A Kruskal-Wallis test was used to investigate significant differences between the manually and automatically obtained volumes of distribution. The algorithm successfully segmented all the studies. No significant differences were found for the same tracer across different segmentation methods. Manual delineation revealed significant differences between DOTANOC and the other two tracers (DOTANOC - DOTATATE, p=0.020; DOTANOC - DOTATOC, p=0.033). Similar differences were found using the leader-follower algorithm. An open implementation of a novel segmentation method for dynamic PET studies is presented and validated in rodent studies. It successfully replicated the manual results obtained in small-animal studies, thus making it a reliable substitute for this task and, potentially, for other dynamic segmentation procedures. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Effects of amyloid and small vessel disease on white matter network disruption.

    PubMed

    Kim, Hee Jin; Im, Kiho; Kwon, Hunki; Lee, Jong Min; Ye, Byoung Seok; Kim, Yeo Jin; Cho, Hanna; Choe, Yearn Seong; Lee, Kyung Han; Kim, Sung Tae; Kim, Jae Seung; Lee, Jae Hong; Na, Duk L; Seo, Sang Won

    2015-01-01

    There is growing evidence that the human brain is a large scale complex network. The structural network is reported to be disrupted in cognitively impaired patients. However, there have been few studies evaluating the effects of amyloid and small vessel disease (SVD) markers, the common causes of cognitive impairment, on structural networks. Thus, we evaluated the association between amyloid and SVD burdens and structural networks using diffusion tensor imaging (DTI). Furthermore, we determined if network parameters predict cognitive impairments. Graph theoretical analysis was applied to DTI data from 232 cognitively impaired patients with varying degrees of amyloid and SVD burdens. All patients underwent Pittsburgh compound-B (PiB) PET to detect amyloid burden, MRI to detect markers of SVD, including the volume of white matter hyperintensities and the number of lacunes, and detailed neuropsychological testing. The whole-brain network was assessed by network parameters of integration (shortest path length, global efficiency) and segregation (clustering coefficient, transitivity, modularity). PiB retention ratio was not associated with any white matter network parameters. Greater white matter hyperintensity volumes or lacunae numbers were significantly associated with decreased network integration (increased shortest path length, decreased global efficiency) and increased network segregation (increased clustering coefficient, increased transitivity, increased modularity). Decreased network integration or increased network segregation were associated with poor performances in attention, language, visuospatial, memory, and frontal-executive functions. Our results suggest that SVD alters white matter network integration and segregation, which further predicts cognitive dysfunction.

  18. Relationship of pericardial fat with lipoprotein distribution: The Multi-Ethnic study of atherosclerosis.

    PubMed

    Ong, Kwok-Leung; Ding, Jingzhong; McClelland, Robyn L; Cheung, Bernard M Y; Criqui, Michael H; Barter, Philip J; Rye, Kerry-Anne; Allison, Matthew A

    2015-08-01

    Pericardial fat and lipoprotein abnormalities contribute to increased risk of cardiovascular disease (CVD). We investigated the relationship between pericardial fat volume and lipoprotein distribution, and whether the association of pericardial fat volume with subclinical atherosclerosis and incident CVD events differs according to lipoprotein distribution. We analyzed data from 5407 participants from the Multi-Ethnic Study of Atherosclerosis who had measurements of pericardial fat volume, lipoprotein distribution, carotid intima-media thickness (IMT), and coronary artery calcium (CAC). All participants were free of clinically apparent CVD at baseline. Incident CVD was defined as any adjudicated CVD event. After adjusting for demographic factors, traditional risk factors, and biomarkers of inflammation and hemostasis, a larger pericardial fat volume was associated with higher large VLDL particle (VLDL-P) concentration and small HDL particle (HDL-P) concentration, and smaller HDL-P size (regression coefficients = 0.585 nmol/L, 0.366 μmol/L, and -0.025 nm per SD increase in pericardial fat volume respectively, all P < 0.05). The association of pericardial fat volume with large VLDL-P concentration and HDL-P size, but not small HDL-P concentration, remained significant after further adjusting for each other as well as LDL cholesterol, HDL cholesterol, and triglycerides. The relationship of pericardial fat volume with incident CVD events, carotid IMT, and prevalence and severity of CAC did not differ by quartiles of large VLDL-P concentration, small HDL-P concentration, or HDL-P size (P for interaction>0.05). Pericardial fat is associated with atherogenic lipoprotein abnormalities. However, its relationship with subclinical atherosclerosis and incident CVD events does not differ according to lipoprotein distribution. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  19. Prototypic Development and Evaluation of a Medium Format Metric Camera

    NASA Astrophysics Data System (ADS)

    Hastedt, H.; Rofallski, R.; Luhmann, T.; Rosenbauer, R.; Ochsner, D.; Rieke-Zapp, D.

    2018-05-01

    Engineering applications require high-precision 3D measurement techniques for object sizes that vary between small volumes (2-3 m in each direction) and large volumes (around 20 x 20 x 1-10 m). The requested precision in object space (1σ RMS) is defined to be within 0.1-0.2 mm for large volumes and less than 0.01 mm for small volumes. In particular, focussing large volume applications the availability of a metric camera would have different advantages for several reasons: 1) high-quality optical components and stabilisations allow for a stable interior geometry of the camera itself, 2) a stable geometry leads to a stable interior orientation that enables for an a priori camera calibration, 3) a higher resulting precision can be expected. With this article the development and accuracy evaluation of a new metric camera, the ALPA 12 FPS add|metric will be presented. Its general accuracy potential is tested against calibrated lengths in a small volume test environment based on the German Guideline VDI/VDE 2634.1 (2002). Maximum length measurement errors of less than 0.025 mm are achieved with different scenarios having been tested. The accuracy potential for large volumes is estimated within a feasibility study on the application of photogrammetric measurements for the deformation estimation on a large wooden shipwreck in the German Maritime Museum. An accuracy of 0.2 mm-0.4 mm is reached for a length of 28 m (given by a distance from a lasertracker network measurement). All analyses have proven high stabilities of the interior orientation of the camera and indicate the applicability for a priori camera calibration for subsequent 3D measurements.

  20. Fetal growth, cognitive function, and brain volumes in childhood and adolescence.

    PubMed

    Rogne, Tormod; Engstrøm, Andreas Aass; Jacobsen, Geir Wenberg; Skranes, Jon; Østgård, Heidi Furre; Martinussen, Marit

    2015-03-01

    To evaluate the association between fetal growth pattern and cognitive function at 5 and 9 years and regional brain volumes at 15 years. Eighty-three term-born small-for-gestational-age (SGA) neonates and 105 non-SGA neonates in a control group were available for follow-up. Based on serial fetal ultrasound measurements from gestational weeks 25-37, SGA neonates were classified with fetal growth restriction (n=13) or non-fetal growth restriction (n=36). Cognitive function was assessed at 5 and 9 years, and brain volumes were estimated with cerebral magnetic resonance imaging at 15 years. Small-for-gestational-age children had lower performance intelligence quotient at 5 years compared with those in a control group (107.3 compared with 112.5, P<.05). Although there were no differences between the SGA non-fetal growth restriction and control groups, the SGA fetal growth restriction group had significantly lower performance intelligence quotient at 5 years (103.5 compared with 112.5, P<.05) and 9 years (96.2 compared with 107.5, P<.05) compared with those in the control group. There were some brain volume differences at 15 years between SGA children and those in the control group, but after adjustment for total intracranial volume, age at examination, and sex, there were only significant differences between the SGA fetal growth restriction and control groups for thalamic (17.4 compared with 18.6 cm, P<.01) and cerebellar white matter volumes (21.5 compared with 24.3 cm, P<.01). Small-for-gestational-age children had lower intelligence quotient scores at 5 and 9 years and smaller brain volumes at 15 years compared with those in the control group, but these findings were only found in those with fetal growth restriction, indicating a possible relationship to decelerated fetal growth. II.

  1. Relationship between pineal cyst size and aqueductal CSF flow measured by phase contrast MRI.

    PubMed

    Bezuidenhout, Abraham F; Kasper, Ekkehard M; Baledent, Olivier; Rojas, Rafael; Bhadelia, Rafeeque A

    2018-02-23

    Most patients with pineal cysts referred for neurosurgical consultation have no specific symptoms or objective findings except for pineal cyst size to help in management decisions. Our purpose was to assess the relationship between pineal cyst size and aqueductal CSF flow using PC-MRI. Eleven adult patients with pineal cysts (> 1-cm in size) referred for neurosurgical consultations were included. Cyst volume was calculated using 3D T1 images. PC-MRI in axial plane with velocity encoding of 5 cm/sec was used to quantitatively assess CSF flow through the cerebral aqueduct to determine the aqueductal stroke volume, which was then correlated to cyst size using Pearson's correlation. Pineal cysts were grouped by size into small (6/11) and large (5/11) using the median value to compare aqueductal stroke volume using Mann-Whitney test. Patients were 39 ± 13 years (mean ± SD) of age, and 10/11 (91%) were female. There was significant negative correlation between cyst volume and aqueductal stroke volume (r=0.74; p=0.009). Volume of small cysts (4954±2157 mm3) was significantly different compared to large cysts (13752±3738 mm3; p= 0.008). The aqueductal stroke volume of patients harboring large cysts 33±8 μL/cardiac cycle was significantly lower than that of patients with small cysts 96±29 μL/cardiac cycle (p=0.008). Aqueductal CSF flow appears to decrease with increasing pineal cyst size. Our preliminary results provide first evidence that even in the absence of objective neurological findings or hydrocephalus; larger pineal cysts already display decreased CSF flow through the cerebral aqueduct.

  2. The Interleukin 3 Gene (IL3) Contributes to Human Brain Volume Variation by Regulating Proliferation and Survival of Neural Progenitors

    PubMed Central

    Huang, Liang; Nho, Kwangsik; Deng, Min; Chen, Qiang; Weinberger, Daniel R.; Vasquez, Alejandro Arias; Rijpkema, Mark; Mattay, Venkata S.; Saykin, Andrew J.; Shen, Li; Fernández, Guillén; Franke, Barbara; Chen, Jing-chun; Chen, Xiang-ning; Wang, Jin-kai; Xiao, Xiao; Qi, Xue-bin; Xiang, Kun; Peng, Ying-Mei; Cao, Xiang-yu; Li, Yi; Shi, Xiao-dong; Gan, Lin; Su, Bing

    2012-01-01

    One of the most significant evolutionary changes underlying the highly developed cognitive abilities of humans is the greatly enlarged brain volume. In addition to being far greater than in most other species, the volume of the human brain exhibits extensive variation and distinct sexual dimorphism in the general population. However, little is known about the genetic mechanisms underlying normal variation as well as the observed sex difference in human brain volume. Here we show that interleukin-3 (IL3) is strongly associated with brain volume variation in four genetically divergent populations. We identified a sequence polymorphism (rs31480) in the IL3 promoter which alters the expression of IL3 by affecting the binding affinity of transcription factor SP1. Further analysis indicated that IL3 and its receptors are continuously expressed in the developing mouse brain, reaching highest levels at postnatal day 1–4. Furthermore, we found IL3 receptor alpha (IL3RA) was mainly expressed in neural progenitors and neurons, and IL3 could promote proliferation and survival of the neural progenitors. The expression level of IL3 thus played pivotal roles in the expansion and maintenance of the neural progenitor pool and the number of surviving neurons. Moreover, we found that IL3 activated both estrogen receptors, but estrogen didn’t directly regulate the expression of IL3. Our results demonstrate that genetic variation in the IL3 promoter regulates human brain volume and reveals novel roles of IL3 in regulating brain development. PMID:23226269

  3. Sewage sludge pasteurization by gamma radiation: Financial viability case studies

    NASA Astrophysics Data System (ADS)

    Swinwood, Jean F.; Kotler, Jiri

    This paper examines the financial viability of sewage sludge pasteurization by gamma radiation, by examining the following three North American scenarios: 1) Small volume sewage treatment plant experiencing high sludge disposal costs. 2) Large volume sewage treatment plant experiencing low sludge disposal costs. 3) Large volume sewage treatment plant experiencing high sludge disposal costs.

  4. Apparent diffusion coefficient of hyperpolarized (3)He with minimal influence of the residual gas in small animals.

    PubMed

    Carrero-González, L; Kaulisch, T; Ruiz-Cabello, J; Pérez-Sánchez, J M; Peces-Barba, G; Stiller, D; Rodríguez, I

    2012-09-01

    The apparent diffusion coefficient (ADC) of hyperpolarized (HP) gases is a parameter that reflects changes in lung microstructure. However, ADC is dependent on many physiological and experimental variables that need to be controlled or specified in order to ensure the reliability and reproducibility of this parameter. A single breath-hold experiment is desirable in order to reduce the amount of consumed HP gas. The application of a positive end-expiratory pressure (PEEP) causes an increase in the residual gas volume. Depending on the applied PEEP, the ratio between the incoming and residual gas volumes will change and the ADC will vary, as long as both gases do not have the same diffusion coefficient. The most standard method for human applications uses air for breathing and a bolus of pure HP (3)He for MRI data acquisition. By applying this method in rats, we have demonstrated that ADC values are strongly dependent on the applied PEEP, and therefore on the residual gas volume in the lung. This outcome will play an important role in studies concerning certain diseases, such as emphysema, which is characterized by an increase in the residual volume. Ventilation with an oxygen-helium mixture (VOHeM) is a proposed single breath-hold method that uses two different gas mixtures (O(2)-(4)He for ventilation and HP (3)He-N(2) for imaging). The concentration of each gas in its respective mixture was calculated in order to obtain the same diffusion coefficient in both mixtures. ADCs obtained from VOHeM are independent of PEEP, thus minimizing the effect of the different residual volumes. Copyright © 2012 John Wiley & Sons, Ltd.

  5. An analytical framework for extracting hydrological information from time series of small reservoirs in a semi-arid region

    NASA Astrophysics Data System (ADS)

    Annor, Frank; van de Giesen, Nick; Bogaard, Thom; Eilander, Dirk

    2013-04-01

    Small water reservoirs for water resources management have as important socio-economic advantage that they bring water close to villages and households. This proximity allows for many water uses in addition to irrigation, such as fisheries, household water, building materials (loam, reeds), tourism and recreation, and cattle watering. These positive aspects are offset by the relatively large evaporative losses in comparison to larger reservoirs, although, it is not exactly known how large these losses are. For decision makers, investors and donors, the decision to construct a small reservoir should be multifactored; and based on economic, socio-cultural and environmental factors. For the latter, getting the water balance and the energy budget of small reservoirs right is key for any environmental impact analyses. For Northern Ghana, the relation between volume of a small reservoir and its' surface area has been established in a robust equation as: Volume = 0.00857Area1.4367 with the surface area explaining more than 95% of the variation in water volume of the reservoirs. This allows the use of remote sensing observations for estimating water volume of small reservoirs in northern Ghana. Hydrological analyses of time series of small reservoir areas comprises estimates of evaporation fluxes and cumulative surface runoff curves. Once the reservoirs are full, spillage will occur and volumes and surface areas remain stable at their maximum extents. This implies that the time series of reservoir surface area contains information concerning the on-set of downstream surface runoff. This on-set does not coincide with the on-set of the rainy season but largely depends on the distribution of rainfall events and storage capacity in the subsurface. The main requirement for this analysis is that the reservoir has negligible seepage losses or water influx from the underlying subsurface. In our research, we carried out a time series analysis of surface area extent for about 45 small reservoirs in the Upper East Region of Ghana. Reservoirs without obvious large seepage losses (field survey) were selected. To verify this, stable water isotopic samples are collected from groundwater upstream and downstream from the reservoir. By looking at possible enrichment of downstream groundwater, a good estimate of seepage can be made in addition to estimates on evaporation. We estimated the evaporative losses and compared those with field measurements using eddy correlation measurements. Lastly, we determined the cumulative surface runoff curves for the small reservoirs .We will present this analytical framework for extracting hydrological information from time series of small reservoirs and show the first results for our study region of northern Ghana.

  6. Computational Modeling to Limit the Impact Displays and Indicator Lights Have on Habitable Volume Operational Lighting Constraints

    NASA Technical Reports Server (NTRS)

    Clark, T. E.; Salazr, G. A; Brainard, G. C.

    2016-01-01

    The goal of this investigation is to determine design limitations and architectural solutions that limit the impact light from displays and indicator lamps have on the operational environment task lighting and lighting countermeasure spectrum constraints. It is concerning that this innovative architectural lighting system, could be compromised by spectrums from display systems, architectural materials, and structures that are not considered as part a full system design implementation. The introduction of many Commercial Off the Shelf (COTS) products to the spacecraft volume that contain LEDs, without consideration to the human factors and biological constraints, is another problem. Displays and indicators are a necessary part of the spacecraft and it is the goal of this research project to determine constraints and solutions that allow these systems to be integrated while minimizing how the lighting environment is modified by them. Due to the potentially broad scope of this endeavor, the project team developed constraints for the evaluation. The evaluation will be on a set of tasks that required significant exposure in the same environment while having a large chance of impacting the light spectrum the crew is expected to receive from the architectural lighting system. The team plans to use recent HRP research on "Net Habitable Volume" [1] to provide the boundary conditions for volume size. A Zemax ® lighting model was developed of a small enclosure that had high intensity overhead lighting and a standard intensity display with LED indicator arrays. The computer model demonstrated a work surface illuminated at a high level by the overhead light source compared to displays and indicators whose light is parallel to the work plane. The overhead lighting oversaturated spectral contributions from the display and indicator at the task work surface. Interestingly, when the observer looked at the displays and LEDs within the small enclosure, their spectral contribution was significant but could be reduced by reflecting overhead light from the wall(s) to the observer. Direct observation of displays and LEDs are an issue because the user's viewing area is a display, not an illuminated work surface. Since avionics command centers consume significant crew time, the tasks that seemed at higher risk for unwanted spectral contributions as an operational volume with significant quantity of displays and indicators that were either under direct observation of the crew or impacting a volume the crew may be required to sleep in.

  7. The intravascular volume effect of Ringer's lactate is below 20%: a prospective study in humans.

    PubMed

    Jacob, Matthias; Chappell, Daniel; Hofmann-Kiefer, Klaus; Helfen, Tobias; Schuelke, Anna; Jacob, Barbara; Burges, Alexander; Conzen, Peter; Rehm, Markus

    2012-05-16

    Isotonic crystalloids play a central role in perioperative fluid management. Isooncotic preparations of colloids (for example, human albumin or hydroxyethyl starch) remain nearly completely intravascular when infused to compensate for acute blood losses. Recent data were interpreted to indicate a comparable intravascular volume effect for crystalloids, challenging the occasionally suggested advantage of using colloids to treat hypovolemia. General physiological knowledge and clinical experience, however, suggest otherwise. In a prospective study, double-tracer blood volume measurements were performed before and after intended normovolemic hemodilution in ten female adults, simultaneously substituting the three-fold amount of withdrawn blood with Ringer's lactate. Any originated deficits were substituted with half the volume of 20% human albumin, followed by a further assessment of blood volume. To assess significance between the measurements, repeated measures analysis of variance (ANOVA) according to Fisher were performed. If significant results were shown, paired t tests (according to Student) for the singular measurements were taken. P < 0.05 was considered to be significant. A total of 1,097 ± 285 ml of whole blood were withdrawn (641 ± 155 ml/m(2) body surface area) and simultaneously replaced by 3,430 ± 806 ml of Ringer's lactate. All patients showed a significant decrease in blood volume after hemodilution (-459 ± 185 ml; P < 0.05) that did not involve relevant hemodynamical changes, and a significant increase in interstitial water content (+2,157 ± 606 ml; P < 0.05). The volume effect of Ringer's lactate was 17 ± 10%. The infusion of 245 ± 64 ml of 20% human albumin in this situation restored blood volume back to baseline values, the volume effect being 184 ± 63%. Substitution of isolated intravascular deficits in cardiopulmonary healthy adults with the three-fold amount of Ringer's lactate impedes maintenance of intravascular normovolemia. The main side effect was an impressive interstitial fluid accumulation, which was partly restored by the intravenous infusion of 20% human albumin. We recommend to substitute the five-fold amount of crystalloids or to use an isooncotic preparation in the face of acute bleeding in patients where edema prevention might be advantageous.

  8. Physiological neuronal decline in healthy aging human brain - An in vivo study with MRI and short echo-time whole-brain (1)H MR spectroscopic imaging.

    PubMed

    Ding, Xiao-Qi; Maudsley, Andrew A; Sabati, Mohammad; Sheriff, Sulaiman; Schmitz, Birte; Schütze, Martin; Bronzlik, Paul; Kahl, Kai G; Lanfermann, Heinrich

    2016-08-15

    Knowledge of physiological aging in healthy human brain is increasingly important for neuroscientific research and clinical diagnosis. To investigate neuronal decline in normal aging brain eighty-one healthy subjects aged between 20 and 70years were studied with MRI and whole-brain (1)H MR spectroscopic imaging. Concentrations of brain metabolites N-acetyl-aspartate (NAA), choline (Cho), total creatine (tCr), myo-inositol (mI), and glutamine+glutamate (Glx) in ratios to internal water, and the fractional volumes of brain tissue were estimated simultaneously in eight cerebral lobes and in cerebellum. Results demonstrated that an age-related decrease in gray matter volume was the largest contribution to changes in brain volume. Both lobar NAA and the fractional volume of gray matter (FVGM) decreased with age in all cerebral lobes, indicating that the decreased NAA was predominantly associated with decreased gray matter volume and neuronal density or metabolic activity. In cerebral white matter Cho, tCr, and mI increased with age in association with increased fractional volume, showing altered cellular membrane turn-over, energy metabolism, and glial activity in human aging white matter. In cerebellum tCr increased while brain tissue volume decreased with age, showing difference to cerebral aging. The observed age-related metabolic and microstructural variations suggest that physiological neuronal decline in aging human brain is associated with a reduction of gray matter volume and neuronal density, in combination with cellular aging in white matter indicated by microstructural alterations and altered energy metabolism in the cerebellum. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Quantification of Protozoa and Viruses from Small Water Volumes

    PubMed Central

    Bonilla, J. Alfredo; Bonilla, Tonya D.; Abdelzaher, Amir M.; Scott, Troy M.; Lukasik, Jerzy; Solo-Gabriele, Helena M.; Palmer, Carol J.

    2015-01-01

    Large sample volumes are traditionally required for the analysis of waterborne pathogens. The need for large volumes greatly limits the number of samples that can be processed. The goals of this study were to compare extraction and detection procedures for quantifying protozoan parasites and viruses from small volumes of marine water. The intent was to evaluate a logistically simpler method of sample collection and processing that would facilitate direct pathogen measures as part of routine monitoring programs. Samples were collected simultaneously using a bilayer device with protozoa capture by size (top filter) and viruses capture by charge (bottom filter). Protozoan detection technologies utilized for recovery of Cryptosporidium spp. and Giardia spp. were qPCR and the more traditional immunomagnetic separation—IFA-microscopy, while virus (poliovirus) detection was based upon qPCR versus plaque assay. Filters were eluted using reagents consistent with the downstream detection technologies. Results showed higher mean recoveries using traditional detection methods over qPCR for Cryptosporidium (91% vs. 45%) and poliovirus (67% vs. 55%) whereas for Giardia the qPCR-based methods were characterized by higher mean recoveries (41% vs. 28%). Overall mean recoveries are considered high for all detection technologies. Results suggest that simultaneous filtration may be suitable for isolating different classes of pathogens from small marine water volumes. More research is needed to evaluate the suitability of this method for detecting pathogens at low ambient concentration levels. PMID:26114244

  10. Quantification of Protozoa and Viruses from Small Water Volumes.

    PubMed

    Bonilla, J Alfredo; Bonilla, Tonya D; Abdelzaher, Amir M; Scott, Troy M; Lukasik, Jerzy; Solo-Gabriele, Helena M; Palmer, Carol J

    2015-06-24

    Large sample volumes are traditionally required for the analysis of waterborne pathogens. The need for large volumes greatly limits the number of samples that can be processed. The aims of this study were to compare extraction and detection procedures for quantifying protozoan parasites and viruses from small volumes of marine water. The intent was to evaluate a logistically simpler method of sample collection and processing that would facilitate direct pathogen measures as part of routine monitoring programs. Samples were collected simultaneously using a bilayer device with protozoa capture by size (top filter) and viruses capture by charge (bottom filter). Protozoan detection technologies utilized for recovery of Cryptosporidium spp. and Giardia spp. were qPCR and the more traditional immunomagnetic separation-IFA-microscopy, while virus (poliovirus) detection was based upon qPCR versus plaque assay. Filters were eluted using reagents consistent with the downstream detection technologies. Results showed higher mean recoveries using traditional detection methods over qPCR for Cryptosporidium (91% vs. 45%) and poliovirus (67% vs. 55%) whereas for Giardia the qPCR-based methods were characterized by higher mean recoveries (41% vs. 28%). Overall mean recoveries are considered high for all detection technologies. Results suggest that simultaneous filtration may be suitable for isolating different classes of pathogens from small marine water volumes. More research is needed to evaluate the suitability of this method for detecting pathogens at low ambient concentration levels.

  11. Constitutive secretion of soluble interleukin-2 receptor by human T cell lymphoma xenografted into SCID mice. Correlation of tumor volume with concentration of tumor-derived soluble interleukin-2 receptor in body fluids of the host mice.

    PubMed Central

    Wasik, M. A.; Sioutos, N.; Tuttle, M.; Butmarc, J. R.; Kaplan, W. D.; Kadin, M. E.

    1994-01-01

    Increased serum concentration of soluble alpha-chain receptor for interleukin-2 (sIL-2R) has been noted in patients with a variety of inflammatory conditions and lymphoid malignancies including T cell leukemia and lymphoma. Elevated sIL-2R serum levels seen in lymphoid malignancies appear to correlate with the clinical stage of disease. However, because sIL-2R is produced by normal activated lymphocytes, it has been uncertain whether serum sIL-2R in such conditions is derived from tumor cells or normal immune cells responding to the tumor. To address this question, we used a model of human (CD30+) anaplastic, large T cell lymphoma transplanted into immunodeficient SCID mice. Reverse transcription polymerase chain reaction of tumor RNA showed that the tumor, designated mJB6, contains mRNA for alpha-chain of human IL-2R. Furthermore, 15 to 25% of tumor cells stained with anti-human IL-2R alpha-chain mAb. Solid phase ELISA analysis of serum samples from mice bearing mJB6 lymphoma showed high concentrations of human sIL-2R. None of the control mice without lymphoma or with human nonlymphoid tumors (prostatic carcinoma, ovarian carcinoma, and glioblastoma multiforme) showed detectable human sIL-2R. The sIL-2R serum titers of mJB6-bearing mice correlated strongly with tumor volume (P < 0.0001). Tumors as small as 0.4 to 0.8 mm3 could be detected by this method. The sensitivity of sIL-2R ELISA exceeded at least 150 times the sensitivity of conventional radioisotopic tumor detection. Total resection of mJB6 tumors resulted in complete clearance of sIL-2R from the murine serum within 48 hours with a half-life of 6 hours. Accordingly, partial resection led to a significant decrease in sIL-2R followed by gradual increase with tumor regrowth. sIL-2R was also detected in the urine of mJB6-transplanted mice. As in serum, urine concentrations of sIL-2R were proportional to tumor mass (P < 0.02). Based on these findings we postulate that malignant cells are a major source of serum sIL-2R in patients with lymphoid tumors. In addition, our data further support monitoring sIL-2R concentration in body fluids as a sensitive method to detect change in tumor volume in such patients. Images Figure 1 Figure 2 PMID:8178932

  12. Metal halides vapor lasers with inner reactor and small active volume.

    NASA Astrophysics Data System (ADS)

    Shiyanov, D. V.; Sukhanov, V. B.; Evtushenko, G. S.

    2018-04-01

    Investigation of the energy characteristics of copper, manganese, lead halide vapor lasers with inner reactor and small active volume 90 cm3 was made. The optimal operating pulse repetition rates, temperatures, and buffer gas pressure for gas discharge tubes with internal and external electrodes are determined. Under identical pump conditions, such systems are not inferior in their characteristics to standard metal halide vapor lasers. It is shown that the use of a zeolite halogen generator provides lifetime laser operation.

  13. Alabama forests: Trends and prospects

    Treesearch

    Paul A. Murphy

    1973-01-01

    Between 1963 and 1972, forest area in Alabama declined 2 percent to 21.3 million acres. Softwood volume increased 30 percent and hardwood 15 percent. Volumes increased in all tree-size classes, but increases were greatest in small trees.

  14. Manipulating biological agents and cells in micro-scale volumes for applications in medicine

    PubMed Central

    Tasoglu, Savas; Gurkan, Umut Atakan; Wang, ShuQi

    2013-01-01

    Recent technological advances provide new tools to manipulate cells and biological agents in micro/nano-liter volumes. With precise control over small volumes, the cell microenvironment and other biological agents can be bioengineered; interactions between cells and external stimuli can be monitored; and the fundamental mechanisms such as cancer metastasis and stem cell differentiation can be elucidated. Technological advances based on the principles of electrical, magnetic, chemical, optical, acoustic, and mechanical forces lead to novel applications in point-of-care diagnostics, regenerative medicine, in vitro drug testing, cryopreservation, and cell isolation/purification. In this review, we first focus on the underlying mechanisms of emerging examples for cell manipulation in small volumes targeting applications such as tissue engineering. Then, we illustrate how these mechanisms impact the aforementioned biomedical applications, discuss the associated challenges, and provide perspectives for further development. PMID:23575660

  15. APOL1 renal-risk variants associate with reduced cerebral white matter lesion volume and increased gray matter volume.

    PubMed

    Freedman, Barry I; Gadegbeku, Crystal A; Bryan, R Nick; Palmer, Nicholette D; Hicks, Pamela J; Ma, Lijun; Rocco, Michael V; Smith, S Carrie; Xu, Jianzhao; Whitlow, Christopher T; Wagner, Benjamin C; Langefeld, Carl D; Hawfield, Amret T; Bates, Jeffrey T; Lerner, Alan J; Raj, Dominic S; Sadaghiani, Mohammad S; Toto, Robert D; Wright, Jackson T; Bowden, Donald W; Williamson, Jeff D; Sink, Kaycee M; Maldjian, Joseph A; Pajewski, Nicholas M; Divers, Jasmin

    2016-08-01

    To assess apolipoprotein L1 gene (APOL1) renal-risk-variant effects on the brain, magnetic resonance imaging (MRI)-based cerebral volumes and cognitive function were assessed in 517 African American-Diabetes Heart Study (AA-DHS) Memory IN Diabetes (MIND) and 2568 hypertensive African American Systolic Blood Pressure Intervention Trial (SPRINT) participants without diabetes. Within these cohorts, 483 and 197 had cerebral MRI, respectively. AA-DHS participants were characterized as follows: 60.9% female, mean age of 58.6 years, diabetes duration 13.1 years, estimated glomerular filtration rate of 88.2 ml/min/1.73 m(2), and a median spot urine albumin to creatinine ratio of 10.0 mg/g. In additive genetic models adjusting for age, sex, ancestry, scanner, intracranial volume, body mass index, hemoglobin A1c, statins, nephropathy, smoking, hypertension, and cardiovascular disease, APOL1 renal-risk-variants were positively associated with gray matter volume (β = 3.4 × 10(-3)) and negatively associated with white matter lesion volume (β = -0.303) (an indicator of cerebral small vessel disease) and cerebrospinal fluid volume (β= -30707) (all significant), but not with white matter volume or cognitive function. Significant associations corresponding to adjusted effect sizes (β/SE) were observed with gray matter volume (0.16) and white matter lesion volume (-0.208), but not with cerebrospinal fluid volume (-0.251). Meta-analysis results with SPRINT Memory and Cognition in Decreased Hypertension (MIND) participants who had cerebral MRI were confirmatory. Thus, APOL1 renal-risk-variants are associated with larger gray matter volume and lower white matter lesion volume suggesting lower intracranial small vessel disease. Copyright © 2016 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.

  16. Ex vivo and in vivo label-free imaging of lymphatic vessels using OCT lymphangiography (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Gong, Peijun; Es'haghian, Shaghayegh; Karnowski, Karol; Rea, Suzanne; Wood, Fiona M.; Yu, Dao-Yi; McLaughlin, Robert A.; Sampson, David D.

    2017-02-01

    We have been developing an automated method to image lymphatic vessels both ex vivo and in vivo with optical coherence tomography (OCT), using their optical transparency. Our method compensates for the OCT signal attenuation for each A-scan in combination with the correction of the confocal function and sensitivity fall-off, enabling reliable thresholding of lymphatic vessels from the OCT scans. Morphological image processing with a segment-joining algorithm is also incorporated into the method to mitigate partial-volume artifacts, which are particularly evident with small lymphatic vessels. Our method is demonstrated for two different clinical application goals: the monitoring of conjunctival lymphatics for surgical guidance and assessment of glaucoma treatment; and the longitudinal monitoring of human burn scars undergoing laser ablation treatment. We present examples of OCT lymphangiography ex vivo on porcine conjunctivas and in vivo on human burn scars, showing the visualization of the lymphatic vessel network and their longitudinal changes due to treatment.

  17. An environmentally-friendly, highly efficient, gas pressure-assisted sample introduction system for ICP-MS and its application to detection of cadmium and lead in human plasma.

    PubMed

    Cao, Yupin; Deng, Biyang; Yan, Lizhen; Huang, Hongli

    2017-05-15

    An environmentally friendly and highly efficient gas pressure-assisted sample introduction system (GPASIS) was developed for inductively-coupled plasma mass spectrometry. A GPASIS consisting of a gas-pressure control device, a customized nebulizer, and a custom-made spray chamber was fabricated. The advantages of this GPASIS derive from its high nebulization efficiencies, small sample volume requirements, low memory effects, good precision, and zero waste emission. A GPASIS can continuously, and stably, nebulize 10% NaCl solution for more than an hour without clogging. Sensitivity, detection limits, precision, long-term stability, double charge and oxide ion levels, nebulization efficiencies, and matrix effects of the sample introduction system were evaluated. Experimental results indicated that the performance of this GPASIS, was equivalent to, or better than, those obtained by conventional sample introduction systems. This GPASIS was successfully used to determine Cd and Pb by ICP-MS in human plasma. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Progress toward automatic classification of human brown adipose tissue using biomedical imaging

    NASA Astrophysics Data System (ADS)

    Gifford, Aliya; Towse, Theodore F.; Walker, Ronald C.; Avison, Malcom J.; Welch, E. B.

    2015-03-01

    Brown adipose tissue (BAT) is a small but significant tissue, which may play an important role in obesity and the pathogenesis of metabolic syndrome. Interest in studying BAT in adult humans is increasing, but in order to quantify BAT volume in a single measurement or to detect changes in BAT over the time course of a longitudinal experiment, BAT needs to first be reliably differentiated from surrounding tissue. Although the uptake of the radiotracer 18F-Fluorodeoxyglucose (18F-FDG) in adipose tissue on positron emission tomography (PET) scans following cold exposure is accepted as an indication of BAT, it is not a definitive indicator, and to date there exists no standardized method for segmenting BAT. Consequently, there is a strong need for robust automatic classification of BAT based on properties measured with biomedical imaging. In this study we begin the process of developing an automated segmentation method based on properties obtained from fat-water MRI and PET-CT scans acquired on ten healthy adult subjects.

  19. An optimized whole blood assay measuring expression and activity of NLRP3, NLRC4 and AIM2 inflammasomes.

    PubMed

    Grinstein, Lev; Endter, Kristin; Hedrich, Christian M; Reinke, Sören; Luksch, Hella; Schulze, Felix; Robertson, Avril A B; Cooper, Matthew A; Rösen-Wolff, Angela; Winkler, Stefan

    2018-06-01

    The proinflammatory protease caspase-1 plays pivotal roles in central pathways of innate immunity, thereby contributing to pathogen clearance. Beside its physiological role, dysregulated activity of caspase-1 is known to contribute to an increasing number of diseases. In this study, we optimized and validated a low-volume human whole blood assay facilitating the measurement of caspase-1 activation and inflammasome-related gene expression upon stimulation of the NLRP3, NLRC4 or AIM2 inflammasome. Using the NLRP3 inflammasome specific inhibitor MCC950, we were able to measure the activity of canonical or alternative NLRP3 pathways, AIM2 and NLRC4 inflammasomes in whole blood. Based on our data we assume a superposition of NLRP3 and NLRC4 inflammasome activities in human whole blood following stimulation with S. typhimurium. The optimized whole blood assay may be suitable for diagnostic and research purposes for pediatric patients who can only donate small amounts of blood. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Extended Gate Field-Effect Transistor Biosensors for Point-Of-Care Testing of Uric Acid.

    PubMed

    Guan, Weihua; Reed, Mark A

    2017-01-01

    An enzyme-free redox potential sensor using off-chip extended-gate field effect transistor (EGFET) with a ferrocenyl-alkanethiol modified gold electrode has been used to quantify uric acid concentration in human serum and urine. Hexacyanoferrate (II) and (III) ions are used as redox reagent. The potentiometric sensor measures the interface potential on the ferrocene immobilized gold electrode, which is modulated by the redox reaction between uric acid and hexacyanoferrate ions. The device shows a near Nernstian response to uric acid and is highly specific to uric acid in human serum and urine. The interference that comes from glucose, bilirubin, ascorbic acid, and hemoglobin is negligible in the normal concentration range of these interferents. The sensor also exhibits excellent long term reliability and is regenerative. This extended gate field effect transistor based sensor is promising for point-of-care detection of uric acid due to the small size, low cost, and low sample volume consumption.

  1. Investigating the Marine Environment and Its Resources, Part II.

    ERIC Educational Resources Information Center

    Lien, Violetta F.

    This is the second of two volumes comprising a resource unit designed to help students become more knowledgeable about the marine environment and its resources. Included in this volume are discussions of changes in the human and marine environment, human needs, marine resources, living marine resources, marine transportation, marine energy…

  2. Common genetic variants influence human subcortical brain structures.

    PubMed

    Hibar, Derrek P; Stein, Jason L; Renteria, Miguel E; Arias-Vasquez, Alejandro; Desrivières, Sylvane; Jahanshad, Neda; Toro, Roberto; Wittfeld, Katharina; Abramovic, Lucija; Andersson, Micael; Aribisala, Benjamin S; Armstrong, Nicola J; Bernard, Manon; Bohlken, Marc M; Boks, Marco P; Bralten, Janita; Brown, Andrew A; Chakravarty, M Mallar; Chen, Qiang; Ching, Christopher R K; Cuellar-Partida, Gabriel; den Braber, Anouk; Giddaluru, Sudheer; Goldman, Aaron L; Grimm, Oliver; Guadalupe, Tulio; Hass, Johanna; Woldehawariat, Girma; Holmes, Avram J; Hoogman, Martine; Janowitz, Deborah; Jia, Tianye; Kim, Sungeun; Klein, Marieke; Kraemer, Bernd; Lee, Phil H; Olde Loohuis, Loes M; Luciano, Michelle; Macare, Christine; Mather, Karen A; Mattheisen, Manuel; Milaneschi, Yuri; Nho, Kwangsik; Papmeyer, Martina; Ramasamy, Adaikalavan; Risacher, Shannon L; Roiz-Santiañez, Roberto; Rose, Emma J; Salami, Alireza; Sämann, Philipp G; Schmaal, Lianne; Schork, Andrew J; Shin, Jean; Strike, Lachlan T; Teumer, Alexander; van Donkelaar, Marjolein M J; van Eijk, Kristel R; Walters, Raymond K; Westlye, Lars T; Whelan, Christopher D; Winkler, Anderson M; Zwiers, Marcel P; Alhusaini, Saud; Athanasiu, Lavinia; Ehrlich, Stefan; Hakobjan, Marina M H; Hartberg, Cecilie B; Haukvik, Unn K; Heister, Angelien J G A M; Hoehn, David; Kasperaviciute, Dalia; Liewald, David C M; Lopez, Lorna M; Makkinje, Remco R R; Matarin, Mar; Naber, Marlies A M; McKay, D Reese; Needham, Margaret; Nugent, Allison C; Pütz, Benno; Royle, Natalie A; Shen, Li; Sprooten, Emma; Trabzuni, Daniah; van der Marel, Saskia S L; van Hulzen, Kimm J E; Walton, Esther; Wolf, Christiane; Almasy, Laura; Ames, David; Arepalli, Sampath; Assareh, Amelia A; Bastin, Mark E; Brodaty, Henry; Bulayeva, Kazima B; Carless, Melanie A; Cichon, Sven; Corvin, Aiden; Curran, Joanne E; Czisch, Michael; de Zubicaray, Greig I; Dillman, Allissa; Duggirala, Ravi; Dyer, Thomas D; Erk, Susanne; Fedko, Iryna O; Ferrucci, Luigi; Foroud, Tatiana M; Fox, Peter T; Fukunaga, Masaki; Gibbs, J Raphael; Göring, Harald H H; Green, Robert C; Guelfi, Sebastian; Hansell, Narelle K; Hartman, Catharina A; Hegenscheid, Katrin; Heinz, Andreas; Hernandez, Dena G; Heslenfeld, Dirk J; Hoekstra, Pieter J; Holsboer, Florian; Homuth, Georg; Hottenga, Jouke-Jan; Ikeda, Masashi; Jack, Clifford R; Jenkinson, Mark; Johnson, Robert; Kanai, Ryota; Keil, Maria; Kent, Jack W; Kochunov, Peter; Kwok, John B; Lawrie, Stephen M; Liu, Xinmin; Longo, Dan L; McMahon, Katie L; Meisenzahl, Eva; Melle, Ingrid; Mohnke, Sebastian; Montgomery, Grant W; Mostert, Jeanette C; Mühleisen, Thomas W; Nalls, Michael A; Nichols, Thomas E; Nilsson, Lars G; Nöthen, Markus M; Ohi, Kazutaka; Olvera, Rene L; Perez-Iglesias, Rocio; Pike, G Bruce; Potkin, Steven G; Reinvang, Ivar; Reppermund, Simone; Rietschel, Marcella; Romanczuk-Seiferth, Nina; Rosen, Glenn D; Rujescu, Dan; Schnell, Knut; Schofield, Peter R; Smith, Colin; Steen, Vidar M; Sussmann, Jessika E; Thalamuthu, Anbupalam; Toga, Arthur W; Traynor, Bryan J; Troncoso, Juan; Turner, Jessica A; Valdés Hernández, Maria C; van 't Ent, Dennis; van der Brug, Marcel; van der Wee, Nic J A; van Tol, Marie-Jose; Veltman, Dick J; Wassink, Thomas H; Westman, Eric; Zielke, Ronald H; Zonderman, Alan B; Ashbrook, David G; Hager, Reinmar; Lu, Lu; McMahon, Francis J; Morris, Derek W; Williams, Robert W; Brunner, Han G; Buckner, Randy L; Buitelaar, Jan K; Cahn, Wiepke; Calhoun, Vince D; Cavalleri, Gianpiero L; Crespo-Facorro, Benedicto; Dale, Anders M; Davies, Gareth E; Delanty, Norman; Depondt, Chantal; Djurovic, Srdjan; Drevets, Wayne C; Espeseth, Thomas; Gollub, Randy L; Ho, Beng-Choon; Hoffmann, Wolfgang; Hosten, Norbert; Kahn, René S; Le Hellard, Stephanie; Meyer-Lindenberg, Andreas; Müller-Myhsok, Bertram; Nauck, Matthias; Nyberg, Lars; Pandolfo, Massimo; Penninx, Brenda W J H; Roffman, Joshua L; Sisodiya, Sanjay M; Smoller, Jordan W; van Bokhoven, Hans; van Haren, Neeltje E M; Völzke, Henry; Walter, Henrik; Weiner, Michael W; Wen, Wei; White, Tonya; Agartz, Ingrid; Andreassen, Ole A; Blangero, John; Boomsma, Dorret I; Brouwer, Rachel M; Cannon, Dara M; Cookson, Mark R; de Geus, Eco J C; Deary, Ian J; Donohoe, Gary; Fernández, Guillén; Fisher, Simon E; Francks, Clyde; Glahn, David C; Grabe, Hans J; Gruber, Oliver; Hardy, John; Hashimoto, Ryota; Hulshoff Pol, Hilleke E; Jönsson, Erik G; Kloszewska, Iwona; Lovestone, Simon; Mattay, Venkata S; Mecocci, Patrizia; McDonald, Colm; McIntosh, Andrew M; Ophoff, Roel A; Paus, Tomas; Pausova, Zdenka; Ryten, Mina; Sachdev, Perminder S; Saykin, Andrew J; Simmons, Andy; Singleton, Andrew; Soininen, Hilkka; Wardlaw, Joanna M; Weale, Michael E; Weinberger, Daniel R; Adams, Hieab H H; Launer, Lenore J; Seiler, Stephan; Schmidt, Reinhold; Chauhan, Ganesh; Satizabal, Claudia L; Becker, James T; Yanek, Lisa; van der Lee, Sven J; Ebling, Maritza; Fischl, Bruce; Longstreth, W T; Greve, Douglas; Schmidt, Helena; Nyquist, Paul; Vinke, Louis N; van Duijn, Cornelia M; Xue, Luting; Mazoyer, Bernard; Bis, Joshua C; Gudnason, Vilmundur; Seshadri, Sudha; Ikram, M Arfan; Martin, Nicholas G; Wright, Margaret J; Schumann, Gunter; Franke, Barbara; Thompson, Paul M; Medland, Sarah E

    2015-04-09

    The highly complex structure of the human brain is strongly shaped by genetic influences. Subcortical brain regions form circuits with cortical areas to coordinate movement, learning, memory and motivation, and altered circuits can lead to abnormal behaviour and disease. To investigate how common genetic variants affect the structure of these brain regions, here we conduct genome-wide association studies of the volumes of seven subcortical regions and the intracranial volume derived from magnetic resonance images of 30,717 individuals from 50 cohorts. We identify five novel genetic variants influencing the volumes of the putamen and caudate nucleus. We also find stronger evidence for three loci with previously established influences on hippocampal volume and intracranial volume. These variants show specific volumetric effects on brain structures rather than global effects across structures. The strongest effects were found for the putamen, where a novel intergenic locus with replicable influence on volume (rs945270; P = 1.08 × 10(-33); 0.52% variance explained) showed evidence of altering the expression of the KTN1 gene in both brain and blood tissue. Variants influencing putamen volume clustered near developmental genes that regulate apoptosis, axon guidance and vesicle transport. Identification of these genetic variants provides insight into the causes of variability in human brain development, and may help to determine mechanisms of neuropsychiatric dysfunction.

  3. Confocal Raman Microscopy for in Situ Measurement of Octanol-Water Partitioning within the Pores of Individual C18-Functionalized Chromatographic Particles.

    PubMed

    Kitt, Jay P; Harris, Joel M

    2015-05-19

    Octanol-water partitioning is one of the most widely used predictors of hydrophobicity and lipophilicity. Traditional methods for measuring octanol-water partition coefficients (K(ow)), including shake-flasks and generator columns, require hours for equilibration and milliliter quantities of sample solution. These challenges have led to development of smaller-scale methods for measuring K(ow). Recent advances in microfluidics have produced faster and smaller-volume approaches to measuring K(ow). As flowing volumes are reduced, however, separation of water and octanol prior to measurement and detection in small volumes of octanol phase are especially challenging. In this work, we reduce the receiver volume of octanol-water partitioning measurements from current practice by six-orders-of-magnitude, to the femtoliter scale, by using a single octanol-filled reversed-phase, octadecylsilane-modified (C18-silica) chromatographic particle as a collector. The fluid-handling challenges of working in such small volumes are circumvented by eliminating postequilibration phase separation. Partitioning is measured in situ within the pore-confined octanol phase using confocal Raman microscopy, which is capable of detecting and quantifying a wide variety of molecular structures. Equilibration times are fast (less than a minute) because molecular diffusion is efficient over distance scales of micrometers. The demonstrated amount of analyte needed to carry out a measurement is very small, less than 50 fmol, which would be a useful attribute for drug screening applications or testing of small quantities of environmentally sensitive compounds. The method is tested for measurements of pH-dependent octanol-water partitioning of naphthoic acid, and the results are compared to both traditional shake-flask measurements and sorption onto C18-modified silica without octanol present within the pores.

  4. A Formula to Calculate Standard Liver Volume Using Thoracoabdominal Circumference.

    PubMed

    Shaw, Brian I; Burdine, Lyle J; Braun, Hillary J; Ascher, Nancy L; Roberts, John P

    2017-12-01

    With the use of split liver grafts as well as living donor liver transplantation (LDLT) it is imperative to know the minimum graft volume to avoid complications. Most current formulas to predict standard liver volume (SLV) rely on weight-based measures that are likely inaccurate in the setting of cirrhosis. Therefore, we sought to create a formula for estimating SLV without weight-based covariates. LDLT donors underwent computed tomography scan volumetric evaluation of their livers. An optimal formula for calculating SLV using the anthropomorphic measure thoracoabdominal circumference (TAC) was determined using leave-one-out cross-validation. The ability of this formula to correctly predict liver volume was checked against other existing formulas by analysis of variance. The ability of the formula to predict small grafts in LDLT was evaluated by exact logistic regression. The optimal formula using TAC was determined to be SLV = (TAC × 3.5816) - (Age × 3.9844) - (Sex × 109.7386) - 934.5949. When compared to historic formulas, the current formula was the only one which was not significantly different than computed tomography determined liver volumes when compared by analysis of variance with Dunnett posttest. When evaluating the ability of the formula to predict small for size syndrome, many (10/16) of the formulas tested had significant results by exact logistic regression, with our formula predicting small for size syndrome with an odds ratio of 7.94 (95% confidence interval, 1.23-91.36; P = 0.025). We report a formula for calculating SLV that does not rely on weight-based variables that has good ability to predict SLV and identify patients with potentially small grafts.

  5. Developmental patterns of chimpanzee cerebral tissues provide important clues for understanding the remarkable enlargement of the human brain.

    PubMed

    Sakai, Tomoko; Matsui, Mie; Mikami, Akichika; Malkova, Ludise; Hamada, Yuzuru; Tomonaga, Masaki; Suzuki, Juri; Tanaka, Masayuki; Miyabe-Nishiwaki, Takako; Makishima, Haruyuki; Nakatsukasa, Masato; Matsuzawa, Tetsuro

    2013-02-22

    Developmental prolongation is thought to contribute to the remarkable brain enlargement observed in modern humans (Homo sapiens). However, the developmental trajectories of cerebral tissues have not been explored in chimpanzees (Pan troglodytes), even though they are our closest living relatives. To address this lack of information, the development of cerebral tissues was tracked in growing chimpanzees during infancy and the juvenile stage, using three-dimensional magnetic resonance imaging and compared with that of humans and rhesus macaques (Macaca mulatta). Overall, cerebral development in chimpanzees demonstrated less maturity and a more protracted course during prepuberty, as observed in humans but not in macaques. However, the rapid increase in cerebral total volume and proportional dynamic change in the cerebral tissue in humans during early infancy, when white matter volume increases dramatically, did not occur in chimpanzees. A dynamic reorganization of cerebral tissues of the brain during early infancy, driven mainly by enhancement of neuronal connectivity, is likely to have emerged in the human lineage after the split between humans and chimpanzees and to have promoted the increase in brain volume in humans. Our findings may lead to powerful insights into the ontogenetic mechanism underlying human brain enlargement.

  6. Developmental patterns of chimpanzee cerebral tissues provide important clues for understanding the remarkable enlargement of the human brain

    PubMed Central

    Sakai, Tomoko; Matsui, Mie; Mikami, Akichika; Malkova, Ludise; Hamada, Yuzuru; Tomonaga, Masaki; Suzuki, Juri; Tanaka, Masayuki; Miyabe-Nishiwaki, Takako; Makishima, Haruyuki; Nakatsukasa, Masato; Matsuzawa, Tetsuro

    2013-01-01

    Developmental prolongation is thought to contribute to the remarkable brain enlargement observed in modern humans (Homo sapiens). However, the developmental trajectories of cerebral tissues have not been explored in chimpanzees (Pan troglodytes), even though they are our closest living relatives. To address this lack of information, the development of cerebral tissues was tracked in growing chimpanzees during infancy and the juvenile stage, using three-dimensional magnetic resonance imaging and compared with that of humans and rhesus macaques (Macaca mulatta). Overall, cerebral development in chimpanzees demonstrated less maturity and a more protracted course during prepuberty, as observed in humans but not in macaques. However, the rapid increase in cerebral total volume and proportional dynamic change in the cerebral tissue in humans during early infancy, when white matter volume increases dramatically, did not occur in chimpanzees. A dynamic reorganization of cerebral tissues of the brain during early infancy, driven mainly by enhancement of neuronal connectivity, is likely to have emerged in the human lineage after the split between humans and chimpanzees and to have promoted the increase in brain volume in humans. Our findings may lead to powerful insights into the ontogenetic mechanism underlying human brain enlargement. PMID:23256194

  7. Renal Artery Embolization Combined With Radiofrequency Ablation in a Porcine Kidney Model: Effect of Small and Narrowly Calibrated Microparticles as Embolization Material on Coagulation Diameter, Volume, and Shape

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sommer, C. M., E-mail: christof.sommer@med.uni-heidelberg.de; Kortes, N.; Zelzer, S.

    2011-02-15

    The purpose of this study was to evaluate the effect of renal artery embolization with small and narrowly calibrated microparticles on the coagulation diameter, volume, and shape of radiofrequency ablations (RFAs) in porcine kidneys. Forty-eight RFAs were performed in 24 kidneys of 12 pigs. In 6 animals, bilateral renal artery embolization was performed with small and narrowly calibrated microparticles. Upper and lower kidney poles were ablated with identical system parameters. Applying three-dimensional segmentation software, RFAs were segmented on registered 2 mm-thin macroscopic slices. Length, depth, width, volume{sub s}egmented, and volume{sub c}alculated were determined to describe the size of the RFAs.more » To evaluate the shape of the RFAs, depth-to-width ratio (perfect symmetry-to-lesion length was indicated by a ratio of 1), sphericity ratio (perfect sphere was indicated by a sphericity ratio of 1), eccentricity (perfect sphere was indicated by an eccentricity of 0), and circularity (perfect circle was indicated by a circularity of 1) were determined. Embolized compared with nonembolized RFAs showed significantly greater depth (23.4 {+-} 3.6 vs. 17.2 {+-} 1.8 mm; p < 0.001) and width (20.1 {+-} 2.9 vs. 12.6 {+-} 3.7 mm; p < 0.001); significantly larger volume{sub s}egmented (8.6 {+-} 3.2 vs. 3.0 {+-} 0.7 ml; p < 0.001) and volume{sub c}alculated (8.4 {+-} 3.0 ml vs. 3.3 {+-} 1.1 ml; p < 0.001); significantly lower depth-to-width (1.17 {+-} 0.10 vs. 1.48 {+-} 0.44; p < 0.05), sphericity (1.55 {+-} 0.44 vs. 1.96 {+-} 0.43; p < 0.01), and eccentricity (0.84 {+-} 0.61 vs. 1.73 {+-} 0.91; p < 0.01) ratios; and significantly greater circularity (0.62 {+-} 0.14 vs. 0.45 {+-} 0.16; p < 0.01). Renal artery embolization with small and narrowly calibrated microparticles affected the coagulation diameter, volume, and shape of RFAs in porcine kidneys. Embolized RFAs were significantly larger and more spherical compared with nonembolized RFAs.« less

  8. The capuchin monkey as a flight candidate

    NASA Technical Reports Server (NTRS)

    Winget, C. M.

    1977-01-01

    The highly evolved nervous system and associated complex behavioral capabilities of the nonhuman primates make them good candidates for certain studies in the space environment since deleterious changes in these more complex aspects of a biological status can only be demonstrated by species which share such highly evolved features with man. Important assets which urge the selection of the capuchin monkey for space experiments include his small size, high intelligence, relative disease resistance, nutritional requirements, and lower volume life support systems. The species is particularly suited for experiments on the nervous system or on process under neural control because of the similarity of capuchin and human blood chemistry profiles and endocrine systems involved in the maintenance of homeostasis and vasomotor tone.

  9. A novel approach for quantitation of glucosylceramide in human dried blood spot using LC-MS/MS.

    PubMed

    Ji, Allena Ji; Wang, Haixing; Ziso-Qejvanaj, Enida; Zheng, Kefei; Chung, Lee Lee; Foley, Timothy; Chuang, Wei-Lien; Richards, Susan; Sung, Crystal

    2015-01-01

    Glucosylceramide, an efficacy biomarker for Gaucher Type 1 disease, exhibits poor solubility in polar solvents and whole blood which makes it difficult to prepare a homogenous blood standard. We developed a novel method using standard addition approach by spiking a small volume of analyte solution on the surface of prespotted dried blood spot. The whole spots were punched out for subsequent extraction and LC-MS/MS analysis. The assay performance met all validation acceptance criteria. Glucosylceramide concentrations in 50 paired plasma and dry blood spot samples obtained from Gaucher Type 1 patients were tested and the results demonstrated the feasibility of using the DBS method for clinical biomarker monitoring. The new approach greatly improves assay precision and accuracy.

  10. [Effects of testosterone and cortisol in sports fatigued organism by Chinese material medica of shixiang yaofa].

    PubMed

    Lu, He-qi; Wei, Bing; Chao, Zhi-mao; Deng, Yun-long; Cheng, Yu-biao; Wang, Ke-lin; Zhou, Yan-hua; Yang, Kun-jie; Zhang, Hai-zhong; Cheng, Zhao-huan

    2007-08-01

    To study the endogenous hormone of testosterone and cortisol that secretes volume and rhythm in sports fatigued human bodies and animals. To determine secretory volume and rhythm in sports fatigued human bodies and animals when Shixiang yaofa's drug are used. Radio-immunity method was used to determine secretory volume and rhythm in sports fatigued human bodies and animals and to analyze secretory volume and rhythm. According to the secretory volume and rhythm of testosterone and cortisol, the Shixiang Yaofa's drugs were used. Doses: wenyang jihuo bead 10 g/sack 2 sack, ziyin xiuyang capsule 0.5 g/pill 8 pill pd in human bodies for 28 days. Wenyang jihuo bead 10 g x kg(-1) of crude drug, ziyin xiuyang capsule 4 g x kg(-1) of crude drug pd for hight doses in animals. Other groups for low doses 5 g x kg(-1) and 2 g x kg(-1) of crude drug pd for 15 days. The blood samples were collected for determination. (1) In human bodies the peak value of testosterone was appeared in 8:00 and valley value was appeared in 18:00, ranges: 176.93-281.73 x 10(-5) mg x L(-1). The peak value of cortisol was appeared in 8:00 and valley value was appeared in 22:00, ranges: 1.31-16.13 x 10(-3) mg x L(-1). In the same condition, the mouse peak value of testosterone was appeared in 20:00 and valley value was appeared in 0:00, ranges: (0.56 x 10(-5) - 124.0 x 10(-5)) mg x L(-1). The rhythm in animals was compatible with human bodies, howerer, the peak value was delayed for 12 hours. (2) The testosterone was step up and the cortisol was cut down in sports fatigued human bodies and animals when shixiang yaofa's drug were used (P < 0.05, P < 0.01). The secretion of testosterone and cortisol in sports fatigued human bodies and animals are existed conclusive biologic rhythm. The secretory volume can be available accommodation by shixiang yaofa's drugs.

  11. The volume of the human knee joint.

    PubMed

    Matziolis, Georg; Roehner, Eric; Windisch, Christoph; Wagner, Andreas

    2015-10-01

    Despite its clinical relevance, particularly in septic knee surgery, the volume of the human knee joint has not been established to date. Therefore, the objective of this study was to determine knee joint volume and whether or not it is dependent on sex or body height. Sixty-one consecutive patients (joints) who were due to undergo endoprosthetic joint replacement were enrolled in this prospective study. During the operation, the joint volume was determined by injecting saline solution until a pressure of 200 mmHg was achieved in the joint. The average volume of all knee joints was 131 ± 53 (40-290) ml. The volume was not found to be dependent on sex, but it was dependent on the patients' height (R = 0.312, p = 0.014). This enabled an estimation of the joint volume according to V = 1.6 height - 135. The considerable inter-individual variance of the knee joint volume would suggest that it should be determined or at least estimated according to body height if the joint volume has consequences for the diagnostics or therapy of knee disorders.

  12. Migratory potential of transplanted glial progenitors as critical factor for successful translation of glia replacement therapy: The gap between mice and men.

    PubMed

    Srivastava, Rohit K; Bulte, Jeff W M; Walczak, Piotr; Janowski, Miroslaw

    2018-05-01

    Neurological disorders are a major threat to public health. Stem cell-based regenerative medicine is now a promising experimental paradigm for its treatment, as shown in pre-clinical animal studies. Initial attempts have been on the replacement of neuronal cells only, but glial progenitors (GPs) are now becoming strong alternative cellular therapeutic candidates to replace oligodendrocytes and astrocytes as knowledge accumulates about their important emerging role in various disease processes. There are many examples of successful therapeutic outcomes for transplanted GPs in small animal models, but clinical translation has proved to be challenging due to the 1,000-fold larger volume of the human brain compared to mice. Human GPs transplanted into the mouse brain migrate extensively and can induce global cell replacement, but a similar extent of migration in the human brain would only allow for local rather than global cell replacement. We review here the mechanisms that govern cell migration, which could potentially be exploited to enhance the migratory properties of GPs through cell engineering pre-transplantation. We furthermore discuss the (dis)advantages of the various cell delivery routes that are available, with particular emphasis on intra-arterial injection as the most suitable route for achieving global cell distribution in the larger brain. Now that therapeutic success has proven to be feasible in small animal models, future efforts will need to be directed to enhance global cell delivery and migration to make bench-to-bedside translation a reality. © 2017 Wiley Periodicals, Inc.

  13. Implications of delayed initiation of radiotherapy: accelerated repopulation after induction chemotherapy for stage III non-small cell lung cancer.

    PubMed

    Chen, Chien P; Weinberg, Vivian K; Jahan, Thierry M; Jablons, David M; Yom, Sue S

    2011-11-01

    For patients with stage III non-small cell lung cancer treated with induction chemotherapy (ICT), delayed initiation of subsequent radiotherapy (RT) may allow for repopulation in the interval between treatment modalities and during the early phase of RT. We quantified the impact of postinduction RT timing by evaluating the pace of tumor regrowth. Institutionally approved retrospective review identified 21 analyzable patients with stage III non-small cell lung cancer who had platinum-based ICT followed by RT+/- chemotherapy from 2002 to 2009. Radiographic response was determined by RECIST criteria and the volume of the single largest tumor mass on the pre-ICT, post-ICT, and RT-planning computed tomography scans. After ICT, the median percent volume change from pre-ICT baseline was -41% (range -86 to +86%). By the RT-planning computed tomography scan, the median percent volume change from the post-ICT timepoint was +40% (range -11 to +311%) and the median volume change was +20 ml (range -4 to 102 ml); these changes were significant (p = 0.0002). Similar results were seen for tumor diameter. A correlation was observed between the amount of delay and degree of regrowth for percent volume (p = 0.0006) and percent diameter change (p = 0.003). A delay greater than 21 days produced greater increases in percent volume change (p = 0.002) and percent diameter (p = 0.055) than lesser delays. After ICT, tumor regrowth can occur within a few weeks. Radiation treatment planning should begin as soon as possible after the administration of ICT to maximize the benefits of cytoreduction.

  14. Rostral cranial fossa as a site for cerebrospinal fluid drainage - volumetric studies in dog breeds of different size and morphotype.

    PubMed

    Sokołowski, Wojciech; Czubaj, Norbert; Skibniewski, Michał; Barszcz, Karolina; Kupczyńska, Marta; Kinda, Wojciech; Kiełbowicz, Zdzisław

    2018-05-18

    Hydrocephalus is a multifactorial condition, whose aetiology is not fully understood. Congenital hydrocephalus frequently occurs in small and brachycephalic dog breeds. Although it is widely accepted that the cribriform plate located in the rostral cranial fossa (RCF) is a site of cerebrospinal fluid (CSF) drainage, the RCF has not been studied extensively. Literature reports indicate that a decreased caudal cranial fossa (CCF) volume in the course of the Chiari-like malformation may obstruct CSF circulation. We hypothesised that morphological diversity among different breeds in the volume of the RCF may affect CSF circulation. The aim of the study was to carry out a volumetric analysis of the RCF and the cranial cavity and to determine the ratio between them in dog breeds of different size and morphotype. We performed computed tomography (CT) morphometric analysis of the RCF compartment by obtaining volume measurements from the transverse and reformatted sagittal and dorsal planes. The rostral cranial fossa percentage - volume of the rostral cranial fossa/volume of cranial cavity × 100 (volRCF/volCC × 100) was lower in small and brachycephalic dog breeds than in the other dogs. A reduced RCF volume was detected in small and brachycephalic dog breeds, some of which are predisposed to congenital hydrocephalus. This may lead to overcrowding of brain parenchyma in the RCF and may impede CSF circulation. Our observations may be useful for future studies focusing on the causes and new therapies to treat conditions such as hydrocephalus and syringomyelia.

  15. Role of land use change in landslide-related sediment fluxes in tropical mountain regions

    NASA Astrophysics Data System (ADS)

    Guns, M.; Vanacker, V.; Demoulin, A.

    2012-04-01

    Tropical mountain regions are characterised by high denudation rates. Landslides are known to be recurrent phenomena in active mountain belts, but their contribution to the overall sedimentary fluxes is not yet well known. Previous studies on sedimentary cascades have mostly focused on natural environments, without considering the impact of human and/or anthropogenic disturbances on sedimentary budgets. In our work, we hypothesise that human-induced land use change might alter the sediment cascade through shifts in the landslide magnitude-frequency relationship. We have tested this assumption in the Virgen Yacu catchment (approximately 11km2), in the Ecuadorian Cordillera Occidental. Landslide inventories and land use maps were established based on a series of sequential aerial photos (1963, 1977, 1984 and 1989), a HR Landsat image (2001) and a VHR WorldView2 image (2010). Aerial photographs were ortho-rectified, and coregistred with the WorldView2 satellite image. Field campaigns were realised in 2010 and 2011 to collect field-based data on landslide type and geometry (depth, width and length). This allowed us to establish an empirical relationship between landslide area and volume, which was then applied to the landslide inventories to estimate landslide-related sediment production rates for various time periods. The contribution of landslides to the overall sediment flux of the catchment was estimated by comparing the landslide-related sediment production to the total sediment yield. The empirical landslide area-volume relationship established here for the Ecuadorian Andes is similar to that derived for the Himalayas. It suggests that landslides are the main source of sediment in this mountainous catchment. First calculations indicate that human-induced land use change alters the magnitude-frequency relationship through strong increase of small landslides.

  16. Pharmacokinetics-Based Identification of Potential Therapeutic Phthalides from XueBiJing, a Chinese Herbal Injection Used in Sepsis Management.

    PubMed

    Zhang, Nating; Cheng, Chen; Olaleye, Olajide E; Sun, Yan; Li, Li; Huang, Yühong; Du, Feifei; Yang, Junling; Wang, Fengqing; Shi, Yanhong; Xu, Fang; Li, Yanfen; Wen, Qi; Zhang, Naixia; Li, Chuan

    2018-06-01

    XueBiJing, an injectable five-herb preparation, has been incorporated into routine sepsis care in China. Phthalides, originating from XueBiJing's component herbs Ligusticum chuanxiong rhizomes and Angelica sinensis roots, are believed to contribute to its therapeutic effects due to their presence in the preparation and antisepsis-related properties. This investigation aimed to identify potential therapeutic phthalides that are bioavailable to act on XueBiJing's therapeutic targets and that could serve as pharmacokinetic markers to supplement classic biomarkers for sepsis care. Among 10 phthalides detected in XueBiJing, senkyunolides I and G were the major circulating phthalides in human subjects, but their different pharmacokinetics might influence their contribution to XueBiJing's therapeutic action. Senkyunolide I exhibited a large distribution volume (1.32 l/kg) and was moderately bound in plasma (54% unbound), whereas senkyunolide G exhibited a small distribution volume (0.10 l/kg) and was extensively bound in plasma (3% unbound). Clearance of senkyunolide I from the systemic circulation was governed by UGT2B15-mediated hepatic glucuronidation; the resulting electrophilic glucuronides were conjugated with glutathione in the liver. Senkyunolide G was selectively bound to albumin (99%) in human plasma. To our knowledge, the human pharmacokinetic data of XueBiJing's phthalides are reported here for the first time. Based on this investigation and such investigations of the other component herbs, follow-up pharmacodynamic assessments of bioavailable herbal compounds are planned to elucidate XueBiJing's chemical basis responsible for its therapeutic action. Senkyunolides I and G, having the preceding disposition characteristics that could be detectably altered by septic pathophysiology, could serve as pharmacokinetic markers for sepsis care. Copyright © 2018 by The American Society for Pharmacology and Experimental Therapeutics.

  17. Detection methods for human enteric viruses in representative foods.

    PubMed

    Leggitt, P R; Jaykus, L A

    2000-12-01

    Although viral foodborne disease is a significant problem, foods are rarely tested for viral contamination, and when done, testing is limited to shellfish commodities. In this work, we report a method to extract and detect human enteric viruses from alternative food commodities using an elution-concentration approach followed by detection using reverse transcription-polymerase chain reaction (RT-PCR). Fifty-gram lettuce or hamburger samples were artificially inoculated with poliovirus type 1 (PV1), hepatitis A virus (HAV), or the Norwalk virus and processed by the sequential steps of homogenization, filtration, Freon extraction (hamburger), and polyethylene glycol (PEG) precipitation. To reduce volumes further and remove RT-PCR inhibitors, a secondary PEG precipitation was necessary, resulting in an overall 10- to 20-fold sample size reduction from 50 g to 3 to 5 ml. Virus recoveries in secondary PEG concentrates ranged from 10 to 70% for PV1 and 2 to 4% for HAV as evaluated by mammalian cell culture infectivity assay. Total RNA from PEG concentrates was extracted to a small volume (30 to 40 microl) and subjected to RT-PCR amplification of viral RNA sequences. Detection limit studies indicated that viral RNA was consistently detected by RT-PCR at initial inoculum levels > or =102 PFU/50-g food sample for PV1 and > or =10(3) PFU/50-g food sample for HAV. In similar studies with the Norwalk virus, detection at inoculum levels > or =1.5 X 10(3) PCR-amplifiable units/50-g sample for both food products was possible. All RT-PCR amplicons were confirmed by subsequent Southern hybridization. The procedure reported represents progress toward the development of methods to detect human enteric viral contamination in foods other than shellfish.

  18. Acute lung injury and persistent small airway disease in a rabbit model of chlorine inhalation.

    PubMed

    Musah, Sadiatu; Schlueter, Connie F; Humphrey, David M; Powell, Karen S; Roberts, Andrew M; Hoyle, Gary W

    2017-01-15

    Chlorine is a pulmonary toxicant to which humans can be exposed through accidents or intentional releases. Acute effects of chlorine inhalation in humans and animal models have been well characterized, but less is known about persistent effects of acute, high-level chlorine exposures. In particular, animal models that reproduce the long-term effects suggested to occur in humans are lacking. Here, we report the development of a rabbit model in which both acute and persistent effects of chlorine inhalation can be assessed. Male New Zealand White rabbits were exposed to chlorine while the lungs were mechanically ventilated. After chlorine exposure, the rabbits were extubated and were allowed to survive for up to 24h after exposure to 800ppm chlorine for 4min to study acute effects or up to 7days after exposure to 400ppm for 8min to study longer term effects. Acute effects observed 6 or 24h after inhalation of 800ppm chlorine for 4min included hypoxemia, pulmonary edema, airway epithelial injury, inflammation, altered baseline lung mechanics, and airway hyperreactivity to inhaled methacholine. Seven days after recovery from inhalation of 400ppm chlorine for 8min, rabbits exhibited mild hypoxemia, increased area of pressure-volume loops, and airway hyperreactivity. Lung histology 7days after chlorine exposure revealed abnormalities in the small airways, including inflammation and sporadic bronchiolitis obliterans lesions. Immunostaining showed a paucity of club and ciliated cells in the epithelium at these sites. These results suggest that small airway disease may be an important component of persistent respiratory abnormalities that occur following acute chlorine exposure. This non-rodent chlorine exposure model should prove useful for studying persistent effects of acute chlorine exposure and for assessing efficacy of countermeasures for chlorine-induced lung injury. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Water Metabolism and Fluid Compartment Volumes in Humans at Altitude. A Compendium of Research (1914 - 1996)

    NASA Technical Reports Server (NTRS)

    Chou, J. L.; Stad, N. J.; Gay, E.; West, G. I.; Barnes, P. R.; Greenleaf, J. E.

    1997-01-01

    This compendium includes abstracts and synopses of clinical observations and of more basic studies involving physiological mechanisms concerning interaction of water metabolism and fluid compartment volumes in humans during altitude exposure. If the author's abstract or summary was appropriate, it was included. In other cases a more detailed synopsis of the paper was prepared under the subheadings Purpose, Methods, Results, and Conclusions. Author and subject indices are provided, plus an additional selected bibliography of related work of those papers received after the volume was being prepared for publication. This volume includes material published from 1914 through 1995.

  20. Alterations in left ventricular volumes induced by Valsalva manoeuvre

    NASA Technical Reports Server (NTRS)

    Brooker, J. Z.; Alderman, E. L.; Harrison, D. C.

    1974-01-01

    Five patients were studied with left ventriculography during different phases of the Valsalva manoeuvre. Small doses of contrast medium allowed adequate repetitive visualization of the left ventricle for volume calculation. During strain phase, the volume of the left ventricle decreased by nearly 50 per cent in each case, and stroke volume and cardiac output also dropped strikingly. Release of straining was attended by a sharp rebound of left ventricular volume to control levels, with a transient surge of increased cardiac output 42 per cent above that of the resting state.

  1. Chemical sensing flow probe

    DOEpatents

    Laguna, George R.; Peter, Frank J.; Butler, Michael A.

    1999-01-01

    A new chemical probe determines the properties of an analyte using the light absorption of the products of a reagent/analyte reaction. The probe places a small reaction volume in contact with a large analyte volume. Analyte diffuses into the reaction volume. Reagent is selectively supplied to the reaction volume. The light absorption of the reaction in the reaction volume indicates properties of the original analyte. The probe is suitable for repeated use in remote or hostile environments. It does not require physical sampling of the analyte or result in significant regent contamination of the analyte reservoir.

  2. Chemical sensing flow probe

    DOEpatents

    Laguna, G.R.; Peter, F.J.; Butler, M.A.

    1999-02-16

    A new chemical probe determines the properties of an analyte using the light absorption of the products of a reagent/analyte reaction. The probe places a small reaction volume in contact with a large analyte volume. Analyte diffuses into the reaction volume. Reagent is selectively supplied to the reaction volume. The light absorption of the reaction in the reaction volume indicates properties of the original analyte. The probe is suitable for repeated use in remote or hostile environments. It does not require physical sampling of the analyte or result in significant regent contamination of the analyte reservoir. 7 figs.

  3. Episodic autobiographical memory is associated with variation in the size of hippocampal subregions.

    PubMed

    Palombo, Daniela J; Bacopulos, Agnes; Amaral, Robert S C; Olsen, Rosanna K; Todd, Rebecca M; Anderson, Adam K; Levine, Brian

    2018-02-01

    Striking individual differences exist in the human capacity to recollect past events, yet, little is known about the neural correlates of such individual differences. Studies investigating hippocampal volume in relation to individual differences in laboratory measures of episodic memory in young adults suggest that whole hippocampal volume is unrelated (or even negatively associated) with episodic memory. However, anatomical and functional specialization across hippocampal subregions suggests that individual differences in episodic memory may be linked to particular hippocampal subregions, as opposed to whole hippocampal volume. Given that the DG/CA 2/3 circuitry is thought to be especially critical for supporting episodic memory in humans, we predicted that the volume of this region would be associated with individual variability in episodic memory. This prediction was supported using high-resolution MRI of the hippocampal subfields and measures of real-world (autobiographical) episodic memory. In addition to the association with DG/CA 2/3 , we further observed a relationship between episodic autobiographical memory and subiculum volume, whereas no association was observed with CA 1 or with whole hippocampal volume. These findings provide insight into the possible neural substrates that mediate individual differences in real-world episodic remembering in humans. © 2017 Wiley Periodicals, Inc.

  4. Simulating the water budget of a Prairie Potholes complex from LiDAR and hydrological models in North Dakota, USA

    USGS Publications Warehouse

    Huang, Shengli; Young, Claudia; Abdul-Aziz, Omar I.; Dahal, Devendra; Feng, Min; Liu, Shuguang

    2013-01-01

    Hydrological processes of the wetland complex in the Prairie Pothole Region (PPR) are difficult to model, partly due to a lack of wetland morphology data. We used Light Detection And Ranging (LiDAR) data sets to derive wetland features; we then modelled rainfall, snowfall, snowmelt, runoff, evaporation, the “fill-and-spill” mechanism, shallow groundwater loss, and the effect of wet and dry conditions. For large wetlands with a volume greater than thousands of cubic metres (e.g. about 3000 m3), the modelled water volume agreed fairly well with observations; however, it did not succeed for small wetlands (e.g. volume less than 450 m3). Despite the failure for small wetlands, the modelled water area of the wetland complex coincided well with interpretation of aerial photographs, showing a linear regression with R2 of around 0.80 and a mean average error of around 0.55 km2. The next step is to improve the water budget modelling for small wetlands.

  5. Predicting treatment related imaging changes (TRICs) after radiosurgery for brain metastases using treatment dose and conformality metrics.

    PubMed

    Taylor, B Frazier; Knisely, Jonathan P; Qian, Jack M; Yu, James B; Chiang, Veronica L

    2016-01-01

    Treatment-related imaging changes (TRICs) after stereotactic radiosurgery (SRS) involves the benign transient enlargement of radiographic lesions after treatment. Identifying the radiation dose volumes and conformality metrics associated with TRICs for different post-treatment periods would be helpful and improve clinical decision making. 367 metastases in 113 patients were treated using Gamma Knife SRS between 1/1/2007-12/31/2009. Each metastasis was measured at each imaging follow-up to detect TRICs (defined as ≥ 20% increase in volume). Fluctuations in small volume lesions (less than 108 mm 3 ) were ignored given widely variable conformity indices (CI) for small volumes. The Karolinska Adverse Radiation Effect (KARE) factor, Paddick's CI, Shaw's CI, tumor volume (TV), 10 Gy (V10) and 12 Gy (V12) volumes, and prescription isodose volume (PIV) were calculated. From 0-6 months, all measures correlated with the incidence of TRICs (p<.001), except KARE, which was inversely correlated. During the 6-12 month period all measures except KARE were still correlated. Beyond 12 months, no correlation was found between any of the measures and the development of TRICs. All metrics except KARE were associated with TRICs from 0-12 months only. Additional patient and treatment factors may become dominant at greater times after SRS.

  6. High correlations between MRI brain volume measurements based on NeuroQuant® and FreeSurfer.

    PubMed

    Ross, David E; Ochs, Alfred L; Tate, David F; Tokac, Umit; Seabaugh, John; Abildskov, Tracy J; Bigler, Erin D

    2018-05-30

    NeuroQuant ® (NQ) and FreeSurfer (FS) are commonly used computer-automated programs for measuring MRI brain volume. Previously they were reported to have high intermethod reliabilities but often large intermethod effect size differences. We hypothesized that linear transformations could be used to reduce the large effect sizes. This study was an extension of our previously reported study. We performed NQ and FS brain volume measurements on 60 subjects (including normal controls, patients with traumatic brain injury, and patients with Alzheimer's disease). We used two statistical approaches in parallel to develop methods for transforming FS volumes into NQ volumes: traditional linear regression, and Bayesian linear regression. For both methods, we used regression analyses to develop linear transformations of the FS volumes to make them more similar to the NQ volumes. The FS-to-NQ transformations based on traditional linear regression resulted in effect sizes which were small to moderate. The transformations based on Bayesian linear regression resulted in all effect sizes being trivially small. To our knowledge, this is the first report describing a method for transforming FS to NQ data so as to achieve high reliability and low effect size differences. Machine learning methods like Bayesian regression may be more useful than traditional methods. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Dead space and tidal volume of the giraffe compared with some other mammals.

    PubMed

    Hugh-Jones, P; Barter, C E; Hime, J M; Rusbridge, M M

    1978-10-01

    The ventilation, tidal volume and anatomical dead-space were measured in a living giraffe and compared with similar measurements in a camel, red deer, llama and man. The giraffe had a resting tidal volume of about 3.3 litres with a dead-space/tidal-volume ratio of 0.34. The giraffe breathes slowly, apparently because of the unusually small diameter of its trachea relative to its length, compared with known measurement in other mammals.

  8. SmallSats, Iodine Propulsion Technology, Applications to Low-Cost Lunar Missions, and the Iodine Satellite (iSAT) Project

    NASA Technical Reports Server (NTRS)

    Dankanich, John W.

    2014-01-01

    Closing Remarks: ?(1) SmallSats hold significant potential for future low cost high value missions; (2) Propulsion remains a key limiting capability for SmallSats that Iodine can address: High ISP * Density for volume constrained spacecraft; Indefinite quiescence, unpressurized and non-hazardous as a secondary payload; (3) Iodine enables MicroSat and SmallSat maneuverability: Enables transfer into high value orbits, constellation deployment and deorbit; (4) Iodine may enable a new class of planetary and exploration class missions: Enables GTO launched secondary spacecraft to transit to the moon, asteroids, and other interplanetary destinations for approximately 150 million dollars full life cycle cost including the launch; (5) ESPA based OTVs are also volume constrained and a shift from xenon to iodine can significantly increase the transfer vehicle change in volume capability including transfers from GTO to a range of Lunar Orbits; (6) The iSAT project is a fast pace high value iodine Hall technology demonstration mission: Partnership with NASA GRC and NASA MSFC with industry partner - Busek; (7) The iSAT mission is an approved project with PDR in November of 2014 and is targeting a flight opportunity in FY17.

  9. Discovery of Novel Human Epidermal Growth Factor Receptor-2 Inhibitors by Structure-based Virtual Screening.

    PubMed

    Shi, Zheng; Yu, Tian; Sun, Rong; Wang, Shan; Chen, Xiao-Qian; Cheng, Li-Jia; Liu, Rong

    2016-01-01

    Human epidermal growth factor receptor-2 (HER2) is a trans-membrane receptor like protein, and aberrant signaling of HER2 is implicated in many human cancers, such as ovarian cancer, gastric cancer, and prostate cancer, most notably breast cancer. Moreover, it has been in the spotlight in the recent years as a promising new target for therapy of breast cancer. Since virtual screening has become an integral part of the drug discovery process, it is of great significant to identify novel HER2 inhibitors by structure-based virtual screening. In this study, we carried out a series of elegant bioinformatics approaches, such as virtual screening and molecular dynamics (MD) simulations to identify HER2 inhibitors from Food and Drug Administration-approved small molecule drug as potential "new use" drugs. Molecular docking identified top 10 potential drugs which showed spectrum affinity to HER2. Moreover, MD simulations suggested that ZINC08214629 (Nonoxynol-9) and ZINC03830276 (Benzonatate) might exert potential inhibitory effects against HER2-targeted anti-breast cancer therapeutics. Together, our findings may provide successful application of virtual screening studies in the lead discovery process, and suggest that our discovered small molecules could be effective HER2 inhibitor candidates for further study. A series of elegant bioinformatics approaches, including virtual screening and molecular dynamics (MD) simulations were took advantage to identify human epidermal growth factor receptor-2 (HER2) inhibitors. Molecular docking recognized top 10 candidate compounds, which showed spectrum affinity to HER2. Further, MD simulations suggested that ZINC08214629 (Nonoxynol-9) and ZINC03830276 (Benzonatate) in candidate compounds were identified as potential "new use" drugs against HER2-targeted anti-breast cancer therapeutics. Abbreviations used: HER2: Human epidermal growth factor receptor-2, FDA: Food and Drug Administration, PDB: Protein Database Bank, RMSDs: Root mean square deviations, SPC: Single point charge, PME: Particle mesh Ewald, NVT: Constant volume, NPT: Constant pressure, RMSF: Root-mean-square fluctuation.

  10. Determination of PCDD/Fs, PBDD/Fs and dioxin-like PCBs in human milk from mothers residing in the rural areas in Flanders, using the CALUX bioassay and GC-HRMS.

    PubMed

    Croes, K; Colles, A; Koppen, G; De Galan, S; Vandermarken, T; Govarts, E; Bruckers, L; Nelen, V; Schoeters, G; Van Larebeke, N; Denison, M S; Mampaey, M; Baeyens, W

    2013-09-15

    Since the CALUX (Chemically Activated LUciferase gene eXpression) bioassay is a fast and inexpensive tool for the determination of dioxin-like compounds in a large number of samples and requires only small sample volumes, the use of this technique in human biomonitoring programs provides a good alternative to GC-HRMS. In this study, a new CALUX method for the separate analysis of PCDD/Fs and dioxin-like PCBs (dl-PCBs) in small amounts of human milk samples with the new sensitive H1L7.5c1 cell line was used to analyze 84 human milk samples, collected from mothers residing in the Flemish rural communities. The geometric mean CALUX-Bioanalytical Equivalent (CALUX-BEQ) values, reported for the 84 mothers from the study area were 10.4 (95% CI: 9.4-11.4) pg CALUX-BEQ per gram lipid or 0.41 (95% CI: 0.37-0.45) pg CALUX-BEQ per gram milk for the PCDD/Fs and 1.73 (1.57-1.91) pg CALUX-BEQ per gram lipid or 0.07 (95% CI: 0.06-0.08) pg CALUX-BEQ per gram milk for the dioxin-like PCBs. Multiple regression analysis showed significant associations between PCDD/Fs and weight change after pregnancy, smoking and consumption of local eggs. One pooled human milk sample was analyzed with both CALUX and GC-HRMS. The ratio of CALUX and GC-HRMS results for this sample were respectively 1.60, 0.58 and 1.23 for the PCDD/Fs, the dl-PCBs and the sum of both fractions, when using the 2005-TEF values. Additionally, also low levels of certain brominated dioxins and furans were detected in the pooled sample with GC-HRMS. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Deviations in expected price impact for small transaction volumes under fee restructuring

    NASA Astrophysics Data System (ADS)

    Harvey, M.; Hendricks, D.; Gebbie, T.; Wilcox, D.

    2017-04-01

    We report on the occurrence of an anomaly in the price impacts of small transaction volumes following a change in the fee structure of an electronic market. We first review evidence for the existence of a master curve for price impact on the Johannesburg Stock Exchange (JSE). On attempting to re-estimate a master curve after fee reductions, it is found that the price impact corresponding to smaller volume trades is greater than expected relative to prior estimates for a range of listed stocks. We show that a master curve for price impact can be found following rescaling by an appropriate liquidity proxy, providing a means for practitioners to approximate price impact curves without onerous processing of tick data.

  12. Measurement of limb volume: laser scanning versus volume displacement.

    PubMed

    McKinnon, John Gregory; Wong, Vanessa; Temple, Walley J; Galbraith, Callum; Ferry, Paul; Clynch, George S; Clynch, Colin

    2007-10-01

    Determining the prevalence and treatment success of surgical lymphedema requires accurate and reproducible measurement. A new method of measurement of limb volume is described. A series of inanimate objects of known and unknown volume was measured using digital laser scanning and water displacement. A similar comparison was made with 10 human volunteers. Digital scanning was evaluated by comparison to the established method of water displacement, then to itself to determine reproducibility of measurement. (1) Objects of known volume: Laser scanning accurately measured the calculated volume but water displacement became less accurate as the size of the object increased. (2) Objects of unknown volume: As average volume increased, there was an increasing bias of underestimation of volume by the water displacement method. The coefficient of reproducibility of water displacement was 83.44 ml. In contrast, the reproducibility of the digital scanning method was 19.0 ml. (3) Human data: The mean difference between water displacement volume and laser scanning volume was 151.7 ml (SD +/- 189.5). The coefficient of reproducibility of water displacement was 450.8 ml whereas for laser scanning it was 174 ml. Laser scanning is an innovative method of measuring tissue volume that combines precision and reproducibility and may have clinical utility for measuring lymphedema. 2007 Wiley-Liss, Inc

  13. Sweat Rates During Continuous and Interval Aerobic Exercise: Implications for NASA Multipurpose Crew Vehicle (MPCV) Missions

    NASA Technical Reports Server (NTRS)

    Ryder, Jeffrey W.; Scott, Jessica; Ploutz-Snyder, Robert; Ploutz-Snyder, Lori L.

    2016-01-01

    Aerobic deconditioning is one of the effects spaceflight. Impaired crewmember performance due to loss of aerobic conditioning is one of the risks identified for mitigation by the NASA Human Research Program. Missions longer than 8 days will involve exercise countermeasures including those aimed at preventing the loss of aerobic capacity. The NASA Multipurpose Crew Vehicle (MPCV) will be NASA's centerpiece architecture for human space exploration beyond low Earth orbit. Aerobic exercise within the small habitable volume of the MPCV is expected to challenge the ability of the environmental control systems, especially in terms of moisture control. Exercising humans contribute moisture to the environment by increased respiratory rate (exhaling air at 100% humidity) and sweat. Current acceptable values are based on theoretical models that rely on an "average" crew member working continuously at 75% of their aerobic capacity (Human Systems Integration Requirements Document). Evidence suggests that high intensity interval exercise for much shorter durations are equally effective or better in building and maintaining aerobic capacity. This investigation will examine sweat and respiratory rates for operationally relevant continuous and interval aerobic exercise protocols using a variety of different individuals. The results will directly inform what types of aerobic exercise countermeasures will be feasible to prescribe for crewmembers aboard the MPCV.

  14. Developing a Salivary Antibody Multiplex Immunoassay to ...

    EPA Pesticide Factsheets

    The etiology and impacts of human exposure to environmental pathogens are of major concern worldwide and, thus, the ability to assess exposure and infections using cost effective, high-throughput approaches would be indispensable. The principal objective of this work is to develop an immunoassay capable of measuring the presence of antibodies in human saliva to multiple pathogens simultaneously. Saliva is particularly attractive in this application because it is noninvasive, cheaper and easier to collect than serum. Antigens from environmental pathogens were coupled to carboxylated microspheres (beads) and used to measure antibodies in very small volumes of human saliva samples using the Luminex xMAP solution-phase assay. Beads were coupled to antigens from Campylobacter jejuni, Helicobacter pylori, Toxoplasma gondii, noroviruses (G I.1 and G II.4) and hepatitis A virus. To ensure that the antigens were sufficiently coupled to the beads, coupling was confirmed using species-specific, animal-derived primary detection antibodies, followed by incubation with biotinylated anti-species secondary detection antibodies and streptavidin-R-phycoerythrin reporter (SAPE). As a control to measure non-specific binding, one bead set was treated identically to the others except it was not coupled to any antigen. The antigen coupled and control beads were then incubated with prospectively-collected human saliva samples, analyzed on a Luminex 100 platform, and the presence

  15. Measured body composition and geometrical data of four ``virtual family'' members for thermoregulatory modeling

    NASA Astrophysics Data System (ADS)

    Xu, Xiaojiang; Rioux, Timothy P.; MacLeod, Tynan; Patel, Tejash; Rome, Maxwell N.; Potter, Adam W.

    2017-03-01

    The purpose of this paper is to develop a database of tissue composition, distribution, volume, surface area, and skin thickness from anatomically correct human models, the virtual family. These models were based on high-resolution magnetic resonance imaging (MRI) of human volunteers, including two adults (male and female) and two children (boy and girl). In the segmented image dataset, each voxel is associated with a label which refers to a tissue type that occupies up that specific cubic millimeter of the body. The tissue volume was calculated from the number of the voxels with the same label. Volumes of 24 organs in body and volumes of 7 tissues in 10 specific body regions were calculated. Surface area was calculated from the collection of voxels that are touching the exterior air. Skin thicknesses were estimated from its volume and surface area. The differences between the calculated and original masses were about 3 % or less for tissues or organs that are important to thermoregulatory modeling, e.g., muscle, skin, and fat. This accurate database of body tissue distributions and geometry is essential for the development of human thermoregulatory models. Data derived from medical imaging provide new effective tools to enhance thermal physiology research and gain deeper insight into the mechanisms of how the human body maintains heat balance.

  16. A homeostatic, chip-based platform for zebrafish larvae immobilization and long-term imaging

    NASA Astrophysics Data System (ADS)

    Friedrich, Timo; Zhu, Feng; Wlodkowic, Donald; Kaslin, Jan

    2015-12-01

    Zebrafish larvae are ideal for toxicology and drug screens due to their transparency, small size and similarity to humans on the genetic level. Using modern imaging techniques, cells and tissues can be dynamically visualised and followed over days in multiple zebrafish. Yet continued imaging experiments require specialized conditions such as: moisture and heat control to maintain specimen homeostasis. Chambers that control the environment are generally very expensive and are not always available for all imaging platforms. A highly customizable mounting configuration with built-in means of controlling temperature and media flow would therefore be a valuable tool for long term imaging experiments. Rapid prototyping using 3D printing is particularly suitable as a production method as it offers high flexibility in design, is widely available and allows a high degree of customizing. We study neural regeneration in zebrafish. Regeneration is limited in humans, but zebrafish recover from neural damage within days. Yet, the underlying regenerative mechanisms remain unclear. We developed an agarose based mounting system that holds the embryos in defined positions along removable strips. Homeostasis and temperature control is ensured by channels circulating buffer and heated water. This allows to image up to 120 larvae simultaneously for more than two days. Its flexibility and the low-volume, high larvae ratio will allow screening of small compound libraries. Taken together, we offer a low cost, highly adaptable solution for long term in-vivo imaging.

  17. Effect of Exercise Training on Hippocampal Volume in Humans: A Pilot Study

    ERIC Educational Resources Information Center

    Parker, Beth A.; Thompson, Paul D.; Jordan, Kathryn C.; Grimaldi, Adam S.; Assaf, Michal; Jagannathan, Kanchana; Pearlson, Godfrey D.

    2011-01-01

    The hippocampus is the primary site of memory and learning in the brain. Both normal aging and various disease pathologies (e.g., alcoholism, schizophrenia, and major depressive disorder) are associated with lower hippocampal volumes in humans and hippocampal atrophy predicts progression of Alzheimers disease. In animals, there is convincing…

  18. Physical Exercise Habits Correlate with Gray Matter Volume of the Hippocampus in Healthy Adult Humans

    NASA Astrophysics Data System (ADS)

    Killgore, William D. S.; Olson, Elizabeth A.; Weber, Mareen

    2013-12-01

    Physical activity facilitates neurogenesis of dentate cells in the rodent hippocampus, a brain region critical for memory formation and spatial representation. Recent findings in humans also suggest that aerobic exercise can lead to increased hippocampal volume and enhanced cognitive functioning in children and elderly adults. However, the association between physical activity and hippocampal volume during the period from early adulthood through middle age has not been effectively explored. Here, we correlated the number of minutes of self-reported exercise per week with gray matter volume of the hippocampus using voxel-based morphometry (VBM) in 61 healthy adults ranging from 18 to 45 years of age. After controlling for age, gender, and total brain volume, total minutes of weekly exercise correlated significantly with volume of the right hippocampus. Findings highlight the relationship between regular physical exercise and brain structure during early to middle adulthood.

  19. Private Dreams, Shared Visions: Student Affairs Work in Small Colleges. National Association of Student Personnel Administrators Monograph Series, Volume 5.

    ERIC Educational Resources Information Center

    Kuh, George D., Ed.; McAleenan, Andrea C., Ed.

    The role of student affairs staff in small colleges is considered in eight chapters. Topics of discussion include: conditions facing small colleges, the small college ecology, the role of the student affairs division in providing leadership for institutional planning and research, examples of innovative programming that maximize scarce resources…

  20. SU-F-J-174: A Series of Computational Human Phantoms in DICOM-RT Format for Normal Tissue Dose Reconstruction in Epidemiological Studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pyakuryal, A; Moroz, B; Lee, C

    2016-06-15

    Purpose: Epidemiological studies of second cancer risk in radiotherapy patients often require individualized dose estimates of normal tissues. Prior to 3D conformal radiation therapy planning, patient anatomy information was mostly limited to 2D radiological images or not even available. Generic patient CT images are often used in commercial radiotherapy treatment planning system (TPS) to reconstruct normal tissue doses. The objective of the current work was to develop a series of reference size computational human phantoms in DICOM-RT format for direct use in dose reconstruction in TPS. Methods: Contours of 93 organs and tissues were extracted from a series of pediatricmore » and adult hybrid computational human phantoms (newborn, 1-, 5-, 10-, 15-year-old, and adult males and females) using Rhinoceros software. A MATLAB script was created to convert the contours into the DICOM-RT structure format. The simulated CT images with the resolution of 1×1×3 mm3 were also generated from the binary phantom format and coupled with the DICOM-structure files. Accurate volumes of the organs were drawn in the format using precise delineation of the contours in converted format. Due to complex geometry of organs, higher resolution (1×1×1 mm3) was found to be more efficient in the conversion of newborn and 1-year-old phantoms. Results: Contour sets were efficiently converted into DICOM-RT structures in relatively short time (about 30 minutes for each phantom). A good agreement was observed in the volumes between the original phantoms and the converted contours for large organs (NRMSD<1.0%) and small organs (NRMSD<7.7%). Conclusion: A comprehensive series of computational human phantoms in DICOM-RT format was created to support epidemiological studies of second cancer risks in radiotherapy patients. We confirmed the DICOM-RT phantoms were successfully imported into the TPS programs of major vendors.« less

Top