Sample records for small volume light

  1. 75 FR 29605 - Clean Alternative Fuel Vehicle and Engine Conversions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-26

    ... Small Volume Manufacturers and Small Volume Test Groups 1. Definition of Small Volume Manufacturers, Small Volume Test Groups, and Small Volume Engine Families a. Light-Duty and Heavy-Duty Complete... and Engines 2. Test Groups, Engine Families, and Evaporative Families a. Test Groups for Light-Duty...

  2. 40 CFR 86.094-14 - Small-volume manufacturers certification procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES General Provisions for Emission Regulations for 1977 and Later Model Year New Light-Duty Vehicles, Light...-Fueled, Liquefied Petroleum Gas-Fueled and Methanol-Fueled Heavy-Duty Vehicles § 86.094-14 Small-volume...

  3. 40 CFR 86.1838-01 - Small-volume manufacturer certification procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES General Compliance Provisions for Control of Air Pollution From New and In-Use Light-Duty Vehicles, Light-Duty Trucks, and Complete Otto-Cycle Heavy-Duty Vehicles § 86.1838-01 Small-volume manufacturer...

  4. Chemical sensing flow probe

    DOEpatents

    Laguna, George R.; Peter, Frank J.; Butler, Michael A.

    1999-01-01

    A new chemical probe determines the properties of an analyte using the light absorption of the products of a reagent/analyte reaction. The probe places a small reaction volume in contact with a large analyte volume. Analyte diffuses into the reaction volume. Reagent is selectively supplied to the reaction volume. The light absorption of the reaction in the reaction volume indicates properties of the original analyte. The probe is suitable for repeated use in remote or hostile environments. It does not require physical sampling of the analyte or result in significant regent contamination of the analyte reservoir.

  5. Chemical sensing flow probe

    DOEpatents

    Laguna, G.R.; Peter, F.J.; Butler, M.A.

    1999-02-16

    A new chemical probe determines the properties of an analyte using the light absorption of the products of a reagent/analyte reaction. The probe places a small reaction volume in contact with a large analyte volume. Analyte diffuses into the reaction volume. Reagent is selectively supplied to the reaction volume. The light absorption of the reaction in the reaction volume indicates properties of the original analyte. The probe is suitable for repeated use in remote or hostile environments. It does not require physical sampling of the analyte or result in significant regent contamination of the analyte reservoir. 7 figs.

  6. Basics of Sterile Compounding: Particulate Matter.

    PubMed

    Akers, Michael J

    2017-01-01

    This article focuses on the requirements for particulate matter in sterile products. Topics include particles and quality, particulate matter standards (large- and small-volume injectables), development of the small-volume injectable test, electronic (light obscuration) and microscope testing, and special requirements for particulate matter in biopharmaceutical preparations. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  7. Computational Modeling to Limit the Impact Displays and Indicator Lights Have on Habitable Volume Operational Lighting Constraints

    NASA Technical Reports Server (NTRS)

    Clark, T. E.; Salazr, G. A; Brainard, G. C.

    2016-01-01

    The goal of this investigation is to determine design limitations and architectural solutions that limit the impact light from displays and indicator lamps have on the operational environment task lighting and lighting countermeasure spectrum constraints. It is concerning that this innovative architectural lighting system, could be compromised by spectrums from display systems, architectural materials, and structures that are not considered as part a full system design implementation. The introduction of many Commercial Off the Shelf (COTS) products to the spacecraft volume that contain LEDs, without consideration to the human factors and biological constraints, is another problem. Displays and indicators are a necessary part of the spacecraft and it is the goal of this research project to determine constraints and solutions that allow these systems to be integrated while minimizing how the lighting environment is modified by them. Due to the potentially broad scope of this endeavor, the project team developed constraints for the evaluation. The evaluation will be on a set of tasks that required significant exposure in the same environment while having a large chance of impacting the light spectrum the crew is expected to receive from the architectural lighting system. The team plans to use recent HRP research on "Net Habitable Volume" [1] to provide the boundary conditions for volume size. A Zemax ® lighting model was developed of a small enclosure that had high intensity overhead lighting and a standard intensity display with LED indicator arrays. The computer model demonstrated a work surface illuminated at a high level by the overhead light source compared to displays and indicators whose light is parallel to the work plane. The overhead lighting oversaturated spectral contributions from the display and indicator at the task work surface. Interestingly, when the observer looked at the displays and LEDs within the small enclosure, their spectral contribution was significant but could be reduced by reflecting overhead light from the wall(s) to the observer. Direct observation of displays and LEDs are an issue because the user's viewing area is a display, not an illuminated work surface. Since avionics command centers consume significant crew time, the tasks that seemed at higher risk for unwanted spectral contributions as an operational volume with significant quantity of displays and indicators that were either under direct observation of the crew or impacting a volume the crew may be required to sleep in.

  8. Functional imaging of small tissue volumes with diffuse optical tomography

    NASA Astrophysics Data System (ADS)

    Klose, Alexander D.; Hielscher, Andreas H.

    2006-03-01

    Imaging of dynamic changes in blood parameters, functional brain imaging, and tumor imaging are the most advanced application areas of diffuse optical tomography (DOT). When dealing with the image reconstruction problem one is faced with the fact that near-infrared photons, unlike X-rays, are highly scattered when they traverse biological tissue. Image reconstruction schemes are required that model the light propagation inside biological tissue and predict measurements on the tissue surface. By iteratively changing the tissue-parameters until the predictions agree with the real measurements, a spatial distribution of optical properties inside the tissue is found. The optical properties can be related to the tissue oxygenation, inflammation, or to the fluorophore concentration of a biochemical marker. If the model of light propagation is inaccurate, the reconstruction process will lead to an inaccurate result as well. Here, we focus on difficulties that are encountered when DOT is employed for functional imaging of small tissue volumes, for example, in cancer studies involving small animals, or human finger joints for early diagnosis of rheumatoid arthritis. Most of the currently employed image reconstruction methods rely on the diffusion theory that is an approximation to the equation of radiative transfer. But, in the cases of small tissue volumes and tissues that contain low scattering regions diffusion theory has been shown to be of limited applicability Therefore, we employ a light propagation model that is based on the equation of radiative transfer, which promises to overcome the limitations.

  9. OML: optical maskless lithography for economic design prototyping and small-volume production

    NASA Astrophysics Data System (ADS)

    Sandstrom, Tor; Bleeker, Arno; Hintersteiner, Jason; Troost, Kars; Freyer, Jorge; van der Mast, Karel

    2004-05-01

    The business case for Maskless Lithography is more compelling than ever before, due to more critical processes, rising mask costs and shorter product cycles. The economics of Maskless Lithography gives a crossover volume from Maskless to mask-based lithography at surprisingly many wafers per mask for surprisingly few wafers per hour throughput. Also, small-volume production will in many cases be more economical with Maskless Lithography, even when compared to "shuttle" schemes, reticles with multiple layers, etc. The full benefit of Maskless Lithography is only achievable by duplicating processes that are compatible with volume production processes on conventional scanners. This can be accomplished by the integration of pattern generators based on spatial light modulator technology with state-of-the-art optical scanner systems. This paper reports on the system design of an Optical Maskless Scanner in development by ASML and Micronic: small-field optics with high demagnification, variable NA and illumination schemes, spatial light modulators with millions of MEMS mirrors on CMOS drivers, a data path with a sustained data flow of more than 250 GPixels per second, stitching of sub-fields to scanner fields, and rasterization and writing strategies for throughput and good image fidelity. Predicted lithographic performance based on image simulations is also shown.

  10. An inexpensive and portable microvolumeter for rapid evaluation of biological samples.

    PubMed

    Douglass, John K; Wcislo, William T

    2010-08-01

    We describe an improved microvolumeter (MVM) for rapidly measuring volumes of small biological samples, including live zooplankton, embryos, and small animals and organs. Portability and low cost make this instrument suitable for widespread use, including at remote field sites. Beginning with Archimedes' principle, which states that immersing an arbitrarily shaped sample in a fluid-filled container displaces an equivalent volume, we identified procedures that maximize measurement accuracy and repeatability across a broad range of absolute volumes. Crucial steps include matching the overall configuration to the size of the sample, using reflected light to monitor fluid levels precisely, and accounting for evaporation during measurements. The resulting precision is at least 100 times higher than in previous displacement-based methods. Volumes are obtained much faster than by traditional histological or confocal methods and without shrinkage artifacts due to fixation or dehydration. Calibrations using volume standards confirmed accurate measurements of volumes as small as 0.06 microL. We validated the feasibility of evaluating soft-tissue samples by comparing volumes of freshly dissected ant brains measured with the MVM and by confocal reconstruction.

  11. On remote sensing of small aerosol particles with polarized light

    NASA Astrophysics Data System (ADS)

    Sun, W.

    2012-12-01

    The CALIPSO satellite mission consistently measures volume (including molecule and particulate) light depolarization ratio of ~2% for smoke, compared to ~1% for marine aerosols and ~15% for dust. The observed ~2% smoke depolarization ratio comes primarily from the nonspherical habits of particles in the smoke at certain particle sizes. The depolarization of linearly polarized light by small sphere aggregates and irregular Gaussian-shaped particles is studied, to reveal the physics between the depolarization of linearly polarized light and aerosol shape and size. It is found that randomly oriented nonspherical particles have some common depolarization properties as functions of scattering angle and size parameter. This may be very useful information for active remote sensing of small nonspherical aerosols using polarized light. We also show that the depolarization ratio from the CALIPSO measurements could be used to derive smoke aerosol particle size. The mean particle size of South-African smoke is estimated to be about half of the 532 nm wavelength of the CALIPSO lidar.

  12. Investigation Development Plan for Reflight of the Small Helium-cooled Infrared Telescope Experiment. Volume 1: Investigation and Technical/management

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The Infrared Telescope (IRT) is designed to survey extended celestial sources of infrared radiation between 4 and 120 micrometers wavelength. It will provide data regarding Space Shuttle induced environmental contamination and the zodical light. And, it will provide experience in the management of large volumes of superfluid helium in the space environment.

  13. Three-dimensional microscopic tomographic imagings of the cataract in a human lens in vivo

    NASA Astrophysics Data System (ADS)

    Masters, Barry R.

    1998-10-01

    The problem of three-dimensional visualization of a human lens in vivo has been solved by a technique of volume rendering a transformed series of 60 rotated Scheimpflug (a dual slit reflected light microscope) digital images. The data set was obtained by rotating the Scheimpflug camera about the optic axis of the lens in 3 degree increments. The transformed set of optical sections were first aligned to correct for small eye movements, and then rendered into a volume reconstruction with volume rendering computer graphics techniques. To help visualize the distribution of lens opacities (cataracts) in the living, human lens the intensity of light scattering was pseudocolor coded and the cataract opacities were displayed as a movie.

  14. 40 CFR 86.099-8 - Emission standards for 1999 and later model year light-duty vehicles.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ....099-8 Emission standards for 1999 and later model year light-duty vehicles. (a)(1)(i)-(ii) [Reserved... schedule of table A99-08 of this section for model year 1999. For small volume manufacturers, the standards... 40 Protection of Environment 19 2013-07-01 2013-07-01 false Emission standards for 1999 and later...

  15. 40 CFR 86.099-8 - Emission standards for 1999 and later model year light-duty vehicles.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ....099-8 Emission standards for 1999 and later model year light-duty vehicles. (a)(1)(i)-(ii) [Reserved... schedule of table A99-08 of this section for model year 1999. For small volume manufacturers, the standards... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Emission standards for 1999 and later...

  16. 40 CFR 86.099-8 - Emission standards for 1999 and later model year light-duty vehicles.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ....099-8 Emission standards for 1999 and later model year light-duty vehicles. (a)(1)(i)-(ii) [Reserved... schedule of table A99-08 of this section for model year 1999. For small volume manufacturers, the standards... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Emission standards for 1999 and later...

  17. 40 CFR 86.099-8 - Emission standards for 1999 and later model year light-duty vehicles.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....099-8 Emission standards for 1999 and later model year light-duty vehicles. (a)(1)(i)-(ii) [Reserved... schedule of table A99-08 of this section for model year 1999. For small volume manufacturers, the standards... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Emission standards for 1999 and later...

  18. Cell volumes, maximal growth rates of unicellular algae and ciliates, and the role of ciliates in the marine pelagial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Banse, K.

    1982-01-01

    A review of growth rates of diatoms and dinoflagellates in light-saturated, nutrient-replete cultures at 20/sup 0/C confirms weak dependence on cell volume or mass. These maximal (intrinsic) rates are not linearly related to surface area or surface-to-volume ratio of the cells. The growth of most diatoms is materially faster than that of dinoflagellates; other algae fall in between or below the dinoflagellates. Small ciliates have appreciably higher intrinsic growth rates than algae of the same cell volume. The average food consumption per ciliate in the marine pelagic realm is inferred to be very low, so that the realized specific growthmore » rates are much smaller than the intrinsic potentials. Also, a previously postulated refuge from predation, afforded by small size, is extended down to about 10-..mu..m/sup 3/ cell volume.« less

  19. [Therapy options for blind microphthalmos and clinical anophthalmos].

    PubMed

    Schittkowski, M P

    2012-11-01

    Children suffering from congenital anophthalmos (absence of eyes) or blind microphthalmos (eyes too small without light perception) show significant smaller eyelids, conjunctival sacs and orbital volume due to the lack of intrauterine growth stimulus. Highly hydrophilic osmotic expanders allow prostheses to be fitted in the first year of life to compensate for the volume deficit and the substantial aesthetic disadvantages and to stimulate lid development.

  20. Weight and volume yields from thinning two oak-hickory stands

    Treesearch

    E. Paul Craft; John E. Baumgras

    1979-01-01

    Two sample plots in oak-hickory stands of poletimber-small sawtimber were thinned to determine product yields from thinnings. One stand received a light thinning; the other was heavily thinned. Light thinning reduced basal area from 120 ft² to 84 ft² per acre and removed 22 tons of roundwopd per acre, including 2,543 board feet of sawed products and 7...

  1. Electromagnetic effects on the light hadron spectrum

    DOE PAGES

    Basak, S.; Bazavov, A.; Bernard, C.; ...

    2015-09-28

    Calculations studying electromagnetic effects on light mesons are reported. The calculations use fully dynamical QCD, but only quenched photons, which suffices to NLO in χPT; that is, the sea quarks are electrically neutral, while the valence quarks carry charge. The non-compact formalism is used for photons. New results are obtained with lattice spacing as small as 0.045 fm and a large range of volumes. The success of chiral perturbation theory in describing these results and the implications for light quark masses are considered.

  2. Tuning the characteristics of surface plasmon polariton nanolasers by tailoring the dispersion relation

    NASA Astrophysics Data System (ADS)

    Lu, Tien-Chang; Chou, Yu-Hsun; Hong, Kuo-Bin; Chung, Yi-Cheng; Lin, Tzy-Rong; Arakelian, S. M.; Alodjants, A. P.

    2017-08-01

    Nanolasers with ultra-compact footprint are able to provide high intensity coherent light, which have various potential applications in high capacity signal processing, biosensing, and sub-wavelength imaging. Among various nanolasers, those lasers with cavities surrounded with metals have shown to have superior light emission properties due to the surface plasmon effect providing better field confinement capability and allowing exotic light-matter interaction. In this talk, we report robust ultraviolet ZnO nanolaser by using silver (Ag) [1] and aluminum (Al) [2] to strongly shrink the mode volume. The nanolasers operated at room temperature and even high temperature (353K) shows several distinct features including an extremely small mode volume, large Purcell factor and group index. Comparison of characteristics between Ag- and Al-based will also be made.

  3. Light-assisted drying (LAD) of small volume biologics: a comparison of two IR light sources

    NASA Astrophysics Data System (ADS)

    Young, Madison A.; Van Vorst, Matthew; Elliott, Gloria D.; Trammell, Susan R.

    2016-03-01

    Protein therapeutics have been developed to treat diseases ranging from arthritis and psoriasis to cancer. A challenge in the development of protein-based drugs is maintaining the protein in the folded state during processing and storage. We are developing a novel processing method, light-assisted drying (LAD), to dehydrate proteins suspended in a sugar (trehalose) solution for storage at supra-zero temperatures. Our technique selectively heats the water in small volume samples using near-IR light to speed dehydration which prevents sugar crystallization that can damage embedded proteins. In this study, we compare the end moisture content (EMC) as a function of processing time of samples dried with two different light sources, Nd:YAG (1064 nm) and Thulium fiber (1850 nm) lasers. EMC is the ratio of water to dry weight in a sample and the lower the EMC the higher the possible storage temperature. LAD with the 1064 and 1850 nm lasers yielded 78% and 65% lower EMC, respectively, than standard air-drying. After 40 minutes of LAD with 1064 and 1850 nm sources, EMCs of 0.27+/-.27 and 0.15+/-.05 gH2O/gDryWeight were reached, which are near the desired value of 0.10 gH2O/gDryWeight that enables storage in a glassy state without refrigeration. LAD is a promising new technique for the preparation of biologics for anhydrous preservation.

  4. Ultrahigh-definition dynamic 3D holographic display by active control of volume speckle fields

    NASA Astrophysics Data System (ADS)

    Yu, Hyeonseung; Lee, Kyeoreh; Park, Jongchan; Park, Yongkeun

    2017-01-01

    Holographic displays generate realistic 3D images that can be viewed without the need for any visual aids. They operate by generating carefully tailored light fields that replicate how humans see an actual environment. However, the realization of high-performance, dynamic 3D holographic displays has been hindered by the capabilities of present wavefront modulator technology. In particular, spatial light modulators have a small diffraction angle range and limited pixel number limiting the viewing angle and image size of a holographic 3D display. Here, we present an alternative method to generate dynamic 3D images by controlling volume speckle fields significantly enhancing image definition. We use this approach to demonstrate a dynamic display of micrometre-sized optical foci in a volume of 8 mm × 8 mm × 20 mm.

  5. A pH sensing system using fluorescence-based fibre optical sensor capable of small volume sample measurement

    NASA Astrophysics Data System (ADS)

    Deng, Shijie; McAuliffe, Michael A. P.; Salaj-Kosla, Urszula; Wolfe, Raymond; Lewis, Liam; Huyet, Guillaume

    2017-02-01

    In this work, a low cost optical pH sensing system that allows for small volume sample measurements was developed. The system operates without the requirement of laboratory instruments (e.g. laser source, spectrometer and CCD camera), this lowers the cost and enhances the portability. In the system, an optical arrangement employing a dichroic filter was used which allows the excitation and emission light to be transmitted using a single fibre thus improving the collection efficiency of the fluorescence signal and also the ability of inserting measurement. The pH sensor in the system uses bromocresol purple as the indicator which is immobilised by sol-gel technology through a dip-coating process. The sensor material was coated on the tip of a 1 mm diameter optical fibre which makes it possible for inserting into very small volume samples to measure the pH. In the system, a LED with a peak emission wavelength of 465 nm is used as the light source and a silicon photo-detector is used to detect the uorescence signal. Optical filters are applied after the LED and in front of the photo-detector to separate the excitation and emission light. The fluorescence signal collected is transferred to a PC through a DAQ and processed by a Labview-based graphic-user-interface (GUI). Experimental results show that the system is capable of sensing pH values from 5.3 to 8.7 with a linear response of R2=0.969. Results also show that the response times for a pH changes from 5.3 to 8.7 is approximately 150 s and for a 0.5 pH changes is approximately 50 s.

  6. Simulating the water budget of a Prairie Potholes complex from LiDAR and hydrological models in North Dakota, USA

    USGS Publications Warehouse

    Huang, Shengli; Young, Claudia; Abdul-Aziz, Omar I.; Dahal, Devendra; Feng, Min; Liu, Shuguang

    2013-01-01

    Hydrological processes of the wetland complex in the Prairie Pothole Region (PPR) are difficult to model, partly due to a lack of wetland morphology data. We used Light Detection And Ranging (LiDAR) data sets to derive wetland features; we then modelled rainfall, snowfall, snowmelt, runoff, evaporation, the “fill-and-spill” mechanism, shallow groundwater loss, and the effect of wet and dry conditions. For large wetlands with a volume greater than thousands of cubic metres (e.g. about 3000 m3), the modelled water volume agreed fairly well with observations; however, it did not succeed for small wetlands (e.g. volume less than 450 m3). Despite the failure for small wetlands, the modelled water area of the wetland complex coincided well with interpretation of aerial photographs, showing a linear regression with R2 of around 0.80 and a mean average error of around 0.55 km2. The next step is to improve the water budget modelling for small wetlands.

  7. Small-volume cavity cell using hollow optical fiber for Raman scattering-based gas detection

    NASA Astrophysics Data System (ADS)

    Okita, Y.; Katagiri, T.; Matsuura, Y.

    2011-03-01

    The highly sensitive Raman cell based on the hollow optical fiber that is suitable for the real-time breath analysis is reported. Hollow optical fiber with inner coating of silver is used as a gas cell and a Stokes light collector. A very small cell whose volume is only 0.4 ml or less enables fast response and real-time measurement of trace gases. To increase the sensitivity the cell is arranged in a cavity which includes of a long-pass filter and a high reflective mirror. The sensitivity of the cavity cell is more than two times higher than that of the cell without cavity.

  8. Rigorous theoretical framework for particle sizing in turbid colloids using light refraction.

    PubMed

    García-Valenzuela, Augusto; Barrera, Rubén G; Gutierrez-Reyes, Edahí

    2008-11-24

    Using a non-local effective-medium approach, we analyze the refraction of light in a colloidal medium. We discuss the theoretical grounds and all the necessary precautions to design and perform experiments to measure the effective refractive index in dilute colloids. As an application, we show that it is possible to retrieve the size of small dielectric particles in a colloid by measuring the complex effective refractive index and the volume fraction occupied by the particles.

  9. Light-induced changes in silicon nanocrystal based solar cells: Modification of silicon-hydrogen bonding on silicon nanocrystal surface under illumination

    NASA Astrophysics Data System (ADS)

    Kim, Ka-Hyun; Johnson, Erik V.; Cabarrocas, Pere Roca i.

    2016-07-01

    Hydrogenated polymorphous silicon (pm-Si:H) is a material consisting of a small volume fraction of nanocrystals embedded in an amorphous matrix. pm-Si:H solar cells demonstrate interesting initial degradation behaviors such as rapid initial change in photovoltaic parameters and self-healing after degradation during light-soaking. The precise dynamics of the light-induced degradation was studied in a series of light-soaking experiments under various illumination conditions such as AM1.5G and filtered 570 nm yellow light. Hydrogen effusion experiment before and after light-soaking further revealed that the initial degradation of pm-Si:H solar cells originate from the modification of silicon-hydrogen bonding on the surface of silicon nanocrystals in pm-Si:H.

  10. New clinical instrument for the early detection of cataract using dynamic light scattering and corneal topography

    NASA Astrophysics Data System (ADS)

    Ansari, Rafat R.; Datiles, Manuel B., III; King, James F.

    2000-06-01

    A growing cataract can be detected at the molecular level using the technique of dynamic light scattering (DLS). However, the success of this method in clinical use depends upon the precise control of the scattering volume inside a patient's eye and especially during patient's repeat visits. This is important because the scattering volume (cross-over region between the scattered light and incident light) inside the eye in a high-quality DLS set-up is very small (few microns in dimension). This precise control holds the key for success in the longitudinal studies of cataract and during anti-cataract drug screening. We have circumvented these problems by fabricating a new DLS fiber optic probe with a working distance of 40 mm and by mounting it inside a cone of a corneal analyzer. This analyzer is frequently used in mapping the corneal topography during PRK (photorefractive keratectomy) and LASIK (laser in situ keratomileusis) procedures in shaping of the cornea to correct myopia. This new instrument and some preliminary clinical tests on one of us (RRA) showing the data reproducibility are described.

  11. Color structured light system of chest wall motion measurement for respiratory volume evaluation

    NASA Astrophysics Data System (ADS)

    Chen, Huijun; Cheng, Yuan; Liu, Dongdong; Zhang, Xiaodong; Zhang, Jue; Que, Chengli; Wang, Guangfa; Fang, Jing

    2010-03-01

    We present a structured light system to dynamically measure human chest wall motion for respiratory volume estimation. Based on a projection of an encoded color pattern and a few active markers attached to the trunk, respiratory volumes are obtained by evaluating the 3-D topographic changes of the chest wall in an anatomically consistent measuring region during respiration. Three measuring setups are established: a single-sided illuminating-recording setup for standing posture, an inclined single-sided setup for supine posture, and a double-sided setup for standing posture. Results are compared with the pneumotachography and show good agreement in volume estimations [correlation coefficient: R>0.99 (P<0.001) for all setups]. The isovolume tests present small variations of the obtained volume during the isovolume maneuver (standard deviation<0.085 L for all setups). After validation by the isovolume test, an investigation of a patient with pleural effusion using the proposed method shows pulmonary functional differences between the diseased and the contralateral sides of the thorax, and subsequent improvement of this imbalance after drainage. These results demonstrate the proposed optical method is capable of not only whole respiratory volume evaluation with high accuracy, but also regional pulmonary function assessment in different chest wall behaviors, with the advantage of whole-field measurement.

  12. In vivo light dosimetry for HPPH-mediated pleural PDT

    NASA Astrophysics Data System (ADS)

    Dimofte, Andreea; Zhu, Timothy C.; Finlay, Jarod C.; Cullighan, Melissa; Edmonds, Christine E.; Friedberg, Joseph S.; Cengel, Keith; Hahn, Stephen M.

    2010-02-01

    This study examines the light fluence (rate) delivered to patients undergoing pleural PDT as a function of treatment time, treatment volume and surface area. The accuracy of treatment delivery is analyzed as a function of the calibration accuracies of each isotropic detector and the calibration integrating sphere. The patients studied here are enrolled in a Phase I clinical trial of HPPH-mediated PDT for the treatment of non-small cell lung cancer with pleural effusion. Patients are administered 4mg per kg body weight HPPH 24-48 hours before the surgery. Patients undergoing photodynamic therapy (PDT) are treated with light therapy with a fluence of 15-60 J/cm2 at 661nm. Fluence rate (mW/cm2) and cumulative fluence (J/cm2) is monitored at 7 different sites during the entire light treatment delivery. Isotropic detectors are used for in-vivo light dosimetry. The anisotropy of each isotropic detector was found to be within 15%. The mean fluence rate delivery and treatment time are recorded. A correlation between the treatment time and the treatment volume is established. The result can be used as a clinical guideline for future pleural PDT treatment.

  13. Method for Measuring the Volume-Scattering Function of Water

    NASA Technical Reports Server (NTRS)

    Agrawal, Yogesh C.

    2009-01-01

    The volume scattering function (VSF) of seawater affects visibility, remote sensing properties, in-water light propagation, lidar performance, and the like. Currently, it s possible to measure only small forward angles of VSF, or to use cumbersome, large, and non-autonomous systems. This innovation is a method of measuring the full range of VSF using a portable instrument. A single rapid-sensing photosensor is used to scan a green laser beam, which delivers the desired measurement. By using a single sensor, inter-calibration is avoided. A compact design is achieved by using drift-free detector electronics, fiber optics, and a new type of photomultiplier. This provides a high angular resolution of 1 or better, as well as the ability to focus in on a VSF region of particular interest. Currently, the total scattering of light is measured as a difference from the other two parts of the light budget equation. This innovation will allow the direct calculation of the total scattering of light by taking an integral of the VSF over all angles. This directly provides one of the three components of the light budget equation, allowing greater versatility in its calculation.

  14. Site Characterization and Analysis Penetrometer System (SCAPS) Heavy Metal Sensors

    DTIC Science & Technology

    2003-04-01

    gigawatts per square centimeter (GW/cm2). Within the small volume about the focal point, rapid heating, vaporization, and ionization of a small amount of the...2001). Briefly, the light emitted from the fiber in the probe is collimated, turned by a quartz prism, and focused by a short- focal -length quartz 5...are decoupled using the configuration shown in Figure 1. The excitation beam is focused by a 25-cm focal length lens through a 2-inch aluminum mirror

  15. Fixture Design for Motion Picture and Theatrical Lighting

    NASA Astrophysics Data System (ADS)

    Dandridge, Susan

    1987-02-01

    I am the Marketing Manager for a fairly good-sized company in a very small industry which is dependent on the efforts of the kind of people attending this conference. Strand Lighting and other companies like mine supply the lighting needs of the entertainment industry. We listen to people like Dan Flannery and Bran Ferrren as well as thousands of other creative, artistic designers, manufacturing the tools they need to bring you everything from Hamlet to Dynasty, from Masterpiece Theatre to The Price is Right. We design and manufacture dimmers, computerized control equipment for the dimmers, and lighting fixtures.It it the issue of lighting fixtures for our industry that brings me here today. The total yearly volume of the entire entertainment lighting industry is estimated at only $70 million. Compare that to the billions of the defense or medical industries.

  16. Microcolumnar and polycrystalline growth of LaBr3:Ce scintillator

    NASA Astrophysics Data System (ADS)

    Nagarkar, V. V.; Miller, S.; Sia, R.; Gaysinskiy, V.

    2011-05-01

    While a wide variety of new scintillators are now available, cerium-doped lanthanide halide scintillators have shown a strong potential toward fulfilling the needs of highly demanding applications such as radioisotope identification at room temperature, homeland security, quantitative molecular imaging for medical diagnostics, and disease staging and research. Despite their extraordinary advantages in terms of light yield and response uniformity over a wide energy range, issues related to reliable, large volume manufacturing of these high-light-yield materials in a rapid and economic manner has not been resolved or purposefully addressed. Here we report on synthesizing LaBr3:Ce scintillator using a thermal evaporation technique, which offers the potential to synthesize large quantities of small-to-large volume, high-quality material in a time-efficient and cost-effective manner. To date we have successfully applied this method to form both microcolumnar films and thick polycrystalline slabs of LaBr3:Ce, and have characterized their light yield, response linearity, decay time and afterglow.

  17. Beam propagation modeling of modified volume Fresnel zone plates fabricated by femtosecond laser direct writing.

    PubMed

    Srisungsitthisunti, Pornsak; Ersoy, Okan K; Xu, Xianfan

    2009-01-01

    Light diffraction by volume Fresnel zone plates (VFZPs) is simulated by the Hankel transform beam propagation method (Hankel BPM). The method utilizes circularly symmetric geometry and small step propagation to calculate the diffracted wave fields by VFZP layers. It is shown that fast and accurate diffraction results can be obtained with the Hankel BPM. The results show an excellent agreement with the scalar diffraction theory and the experimental results. The numerical method allows more comprehensive studies of the VFZP parameters to achieve higher diffraction efficiency.

  18. Axonal inclusions in the crab Hemigrapsus nudus.

    PubMed

    Smith, R S

    1978-10-01

    Light microscopic examination of living giant axons from the walking legs of Hemigrapsus nudus revealed intra-axonal inclusions which were usually several tens of micrometers long and about 5 micron wide. The inclusions were filled with small light-scattering particles. The inclusions were shown, by thin section electron microscopy, to be composed largely 68% by volume) of mitochondria. Each inclusion was surrounded by membrane bounded spaces which are presumed to represent a part of the smooth endoplasmic reticulum. Similar inclusions were not found in the leg axons of a variety of other decapod crustaceans.

  19. Nonintrusive iris image acquisition system based on a pan-tilt-zoom camera and light stripe projection

    NASA Astrophysics Data System (ADS)

    Yoon, Soweon; Jung, Ho Gi; Park, Kang Ryoung; Kim, Jaihie

    2009-03-01

    Although iris recognition is one of the most accurate biometric technologies, it has not yet been widely used in practical applications. This is mainly due to user inconvenience during the image acquisition phase. Specifically, users try to adjust their eye position within small capture volume at a close distance from the system. To overcome these problems, we propose a novel iris image acquisition system that provides users with unconstrained environments: a large operating range, enabling movement from standing posture, and capturing good-quality iris images in an acceptable time. The proposed system has the following three contributions compared with previous works: (1) the capture volume is significantly increased by using a pan-tilt-zoom (PTZ) camera guided by a light stripe projection, (2) the iris location in the large capture volume is found fast due to 1-D vertical face searching from the user's horizontal position obtained by the light stripe projection, and (3) zooming and focusing on the user's irises at a distance are accurate and fast using the estimated 3-D position of a face by the light stripe projection and the PTZ camera. Experimental results show that the proposed system can capture good-quality iris images in 2.479 s on average at a distance of 1.5 to 3 m, while allowing a limited amount of movement by the user.

  20. Development and investigation of single-scan TV radiography for the acquisition of dynamic physiologic data

    NASA Technical Reports Server (NTRS)

    Baily, N. A.

    1975-01-01

    A light amplifier for large flat screen fluoroscopy was investigated which will decrease both its size and weight. The work on organ contouring was extended to yield volumes. This is a simple extension since the fluoroscopic image contains density (gray scale) information which can be translated as tissue thickness, integrated, yielding accurate volume data in an on-line situation. A number of devices were developed for analog image processing of video signals, operating on-line in real time, and with simple selection mechanisms. The results show that this approach is feasible and produces are improvement in image quality which should make diagnostic error significantly lower. These are all low cost devices, small and light in weight, thereby making them usable in a space environment, on the Ames centrifuge, and in a typical clinical situation.

  1. Light dosimetry and dose verification for pleural PDT

    NASA Astrophysics Data System (ADS)

    Dimofte, Andreea; Sharikova, Anna V.; Meo, Julia L.; Simone, Charles B.; Friedberg, Joseph S.; Zhu, Timothy C.

    2013-03-01

    In-vivo light dosimetry for patients undergoing photodynamic therapy (PDT) is critical for predicting PDT outcome. Patients in this study are enrolled in a Phase I clinical trial of HPPH-mediated PDT for the treatment of non-small cell lung cancer with pleural effusion. They are administered 4mg per kg body weight HPPH 48 hours before the surgery and receive light therapy with a fluence of 15-45 J/cm2 at 661 and 665nm. Fluence rate (mW/cm2) and cumulative fluence (J/cm2) are monitored at 7 sites during the light treatment delivery using isotropic detectors. Light fluence (rate) delivered to patients is examined as a function of treatment time, volume and surface area. In a previous study, a correlation between the treatment time and the treatment volume and surface area was established. However, we did not include the direct light and the effect of the shape of the pleural surface on the scattered light. A real-time infrared (IR) navigation system was used to separate the contribution from the direct light. An improved expression that accurately calculates the total fluence at the cavity wall as a function of light source location, cavity geometry and optical properties is determined based on theoretical and phantom studies. The theoretical study includes an expression for light fluence rate in an elliptical geometry instead of the spheroid geometry used previously. The calculated light fluence is compared to the measured fluence in patients of different cavity geometries and optical properties. The result can be used as a clinical guideline for future pleural PDT treatment.

  2. And There Was Light: Prospects for the Creation of Micro- and Nanostructures through Maskless Photolithography.

    PubMed

    Rühe, J

    2017-09-26

    In photolithographic processes, the light inducing the photochemical reactions is confined to a small volume, which enables direct writing of micro- and nanoscale features onto solid surfaces without the need of a predefined photomask. The direct writing process can be used to generate topographic patterns through photopolymerization or photo-cross-linking or can be employed to use light to generate chemical patterns on the surface with high spatial control, which would make such processes attractive for bioapplications. The prospects of maskless photolithography technologies with a focus on two-photon lithography and scanning-probe-based photochemical processes based on scanning near-field optical microscopy or beam pen lithography are discussed.

  3. Research of the small satellite data management system

    NASA Astrophysics Data System (ADS)

    Yu, Xiaozhou; Zhou, Fengqi; Zhou, Jun

    2007-11-01

    Small satellite is the integration of light weight, small volume and low launch cost. It is a promising approach to realize the future space mission. A detailed study of the data management system has been carried out, with using new reconfiguration method based on System On Programmable Chip (SOPC). Compared with common structure of satellite, the Central Terminal Unit (CTU), the Remote Terminal Unit (RTU) and Serial Data Bus (SDB) of the data management are all integrated in single chip. Thus the reliability of the satellite is greatly improved. At the same time, the data management system has powerful performance owing to the modern FPGA processing ability.

  4. Optical Addressing of Multi-Colour Photochromic Material Mixture for Volumetric Display.

    PubMed

    Hirayama, Ryuji; Shiraki, Atsushi; Naruse, Makoto; Nakamura, Shinichiro; Nakayama, Hirotaka; Kakue, Takashi; Shimobaba, Tomoyoshi; Ito, Tomoyoshi

    2016-08-16

    This is the first study to demonstrate that colour transformations in the volume of a photochromic material (PM) are induced at the intersections of two control light channels, one controlling PM colouration and the other controlling decolouration. Thus, PM colouration is induced by position selectivity, and therefore, a dynamic volumetric display may be realised using these two control lights. Moreover, a mixture of multiple PM types with different absorption properties exhibits different colours depending on the control light spectrum. Particularly, the spectrum management of the control light allows colour-selective colouration besides position selectivity. Therefore, a PM-based, full-colour volumetric display is realised. We experimentally construct a mixture of two PM types and validate the operating principles of such a volumetric display system. Our system is constructed simply by mixing multiple PM types; therefore, the display hardware structure is extremely simple, and the minimum size of a volume element can be as small as the size of a molecule. Volumetric displays can provide natural three-dimensional (3D) perception; therefore, the potential uses of our system include high-definition 3D visualisation for medical applications, architectural design, human-computer interactions, advertising, and entertainment.

  5. Optical Addressing of Multi-Colour Photochromic Material Mixture for Volumetric Display

    NASA Astrophysics Data System (ADS)

    Hirayama, Ryuji; Shiraki, Atsushi; Naruse, Makoto; Nakamura, Shinichiro; Nakayama, Hirotaka; Kakue, Takashi; Shimobaba, Tomoyoshi; Ito, Tomoyoshi

    2016-08-01

    This is the first study to demonstrate that colour transformations in the volume of a photochromic material (PM) are induced at the intersections of two control light channels, one controlling PM colouration and the other controlling decolouration. Thus, PM colouration is induced by position selectivity, and therefore, a dynamic volumetric display may be realised using these two control lights. Moreover, a mixture of multiple PM types with different absorption properties exhibits different colours depending on the control light spectrum. Particularly, the spectrum management of the control light allows colour-selective colouration besides position selectivity. Therefore, a PM-based, full-colour volumetric display is realised. We experimentally construct a mixture of two PM types and validate the operating principles of such a volumetric display system. Our system is constructed simply by mixing multiple PM types; therefore, the display hardware structure is extremely simple, and the minimum size of a volume element can be as small as the size of a molecule. Volumetric displays can provide natural three-dimensional (3D) perception; therefore, the potential uses of our system include high-definition 3D visualisation for medical applications, architectural design, human-computer interactions, advertising, and entertainment.

  6. Fan-beam scanning laser optical computed tomography for large volume dosimetry

    NASA Astrophysics Data System (ADS)

    Dekker, K. H.; Battista, J. J.; Jordan, K. J.

    2017-05-01

    A prototype scanning-laser fan beam optical CT scanner is reported which is capable of high resolution, large volume dosimetry with reasonable scan time. An acylindrical, asymmetric aquarium design is presented which serves to 1) generate parallel-beam scan geometry, 2) focus light towards a small acceptance angle detector, and 3) avoid interference fringe-related artifacts. Preliminary experiments with uniform solution phantoms (11 and 15 cm diameter) and finger phantoms (13.5 mm diameter FEP tubing) demonstrate that the design allows accurate optical CT imaging, with optical CT measurements agreeing within 3% of independent Beer-Lambert law calculations.

  7. For the depolarization of linearly polarized light by smoke particles

    NASA Astrophysics Data System (ADS)

    Sun, Wenbo; Liu, Zhaoyan; Videen, Gorden; Fu, Qiang; Muinonen, Karri; Winker, David M.; Lukashin, Constantine; Jin, Zhonghai; Lin, Bing; Huang, Jianping

    2013-06-01

    The CALIPSO satellite mission consistently measures volume (including molecule and particulate) light depolarization ratio of ∼2% for smoke, compared to ∼1% for marine aerosols and ∼15% for dust. The observed ∼2% smoke depolarization ratio comes primarily from the nonspherical habits of particles in the smoke at certain particle sizes. In this study, the depolarization of linearly polarized light by small sphere aggregates and irregular Gaussian-shaped particles is studied, to reveal the physics between the depolarization of linearly polarized light and smoke aerosol shape and size. It is found that the depolarization ratio curves of Gaussian-deformed spheres are very similar to sphere aggregates in terms of scattering-angle dependence and particle size parameters when particle size parameter is smaller than 1.0π. This demonstrates that small randomly oriented nonspherical particles have some common depolarization properties as functions of scattering angle and size parameter. This may be very useful information for characterization and active remote sensing of smoke particles using polarized light. We also show that the depolarization ratio from the CALIPSO measurements could be used to derive smoke aerosol particle size. From the calculation results for light depolarization ratio by Gaussian-shaped smoke particles and the CALIPSO-measured light depolarization ratio of ∼2% for smoke, the mean particle size of South-African smoke is estimated to be about half of the 532nm wavelength of the CALIPSO lidar.

  8. In vivo light dosimetry for pleural PDT

    NASA Astrophysics Data System (ADS)

    Dimofte, Andreea; Zhu, Timothy C.; Finlay, Jarod C.; Culligan, Melissa; Edmonds, Christine E.; Friedberg, Joseph S.; Cengel, Keith; Hahn, Stephen M.

    2009-02-01

    In-vivo light Dosimetry for patients undergoing photodynamic therapy (PDT) is one of the important dosimetry quantities critical for predicting PDT outcome. This study examines the light fluence (rate) delivered to patients undergoing pleural PDT as a function of treatment time, treatment volume and surface area, and its accuracy as a function of the calibration accuracies of each isotropic detector and the calibration integrating sphere. The patients studied here were enrolled in Phase II clinical trial of Photofrin-mediated PDT for the treatment of non-small cell lung cancer with pleural effusion. The ages of the patients studied varied from 34 to 69 year old. All patients were administered 2mg per kg body weight Photoprin 24 hours before the surgery. Patients undergoing photodynamic therapy (PDT) are treated with laser light with a light fluence of 60 J/cm^2 at 630nm. Fluence rate (mW/cm^2) and cumulative fluence (J/cm^2) was monitored at 7 different sites during the entire light treatment delivery. Isotropic detectors were used for in-vivo light dosimetry. The anisotropy of each isotropic detector was found to be within 30%. The mean fluence rate delivery varied from 37.84 to 94.05 mW/cm^2 and treatment time varied from 1762 to 5232s. We have established a correlation between the treatment time and the treatment volume. The results are discussed using an integrating sphere theory and the measured tissue optical properties. The result can be used as a clinical guideline for future pleural PDT treatment.

  9. Robust sensor for turbidity measurement from light scattering and absorbing liquids.

    PubMed

    Kontturi, Ville; Turunen, Petri; Uozumi, Jun; Peiponen, Kai-Erik

    2009-12-01

    Internationally standardized turbidity measurements for probing solid particles in liquid are problematic in the case of simultaneous light scattering and absorption. A method and a sensor to determine the turbidity in the presence of light absorption are presented. The developed sensor makes use of the total internal reflection of a laser beam at the liquid-prism interface, and the turbidity is assessed using the concept of laser speckle pattern. Using average filtering in speckle data analyzing the observed dynamic speckle pattern, which is due to light scattering from particles and the static speckle due to stray light of the sensor, can be separated from each other. Good correlation between the standard deviation of dynamic speckle and turbidity value for nonabsorbing and for absorbing liquids was observed. The sensor is suggested, for instance, for the measurement of ill-behaved as well as small-volume turbid liquids in both medicine and process industry.

  10. A New Clinical Instrument for The Early Detection of Cataract Using Dynamic Light Scattering and Corneal Topography

    NASA Technical Reports Server (NTRS)

    Ansari, Rafat R.; Datiles, Manuel B., III; King, James F.

    2000-01-01

    A growing cataract can be detected at the molecular level using the technique of dynamic light scattering (DLS). However, the success of this method in clinical use depends upon the precise control of the scattering volume inside a patient's eye and especially during patient's repeat visits. This is important because the scattering volume (cross-over region between the scattered fight and incident light) inside the eye in a high-quality DLS set-up is very small (few microns in dimension). This precise control holds the key for success in the longitudinal studies of cataract and during anti-cataract drug screening. We have circumvented these problems by fabricating a new DLS fiber optic probe with a working distance of 40 mm and by mounting it inside a cone of a corneal analyzer. This analyzer is frequently used in mapping the corneal topography during PRK (photorefractive keratectomy) and LASIK (laser in situ keratomileusis) procedures in shaping of the cornea to correct myopia. This new instrument and some preliminary clinical tests on one of us (RRA) showing the data reproducibility are described.

  11. Photolithographic patterning of vacuum-deposited organic light emitting devices

    NASA Astrophysics Data System (ADS)

    Tian, P. F.; Burrows, P. E.; Forrest, S. R.

    1997-12-01

    We demonstrate a photolithographic technique to fabricate vacuum-deposited organic light emitting devices. Photoresist liftoff combined with vertical deposition of the emissive organic materials and the metal cathode, followed by oblique deposition of a metal cap, avoids the use of high processing temperatures and the exposure of the organic materials to chemical degradation. The unpackaged devices show no sign of deterioration in room ambient when compared with conventional devices fabricated using low-resolution, shadow mask patterning. Furthermore, the devices are resistant to rapid degradation when operated in air for extended periods. This work illustrates a potential foundation for the volume production of very high-resolution, full color, flat panel displays based on small molecular weight organic light emitting devices.

  12. Multilayered metal-insulator nanocavities: toward tunable multi-resonance nano-devices for integrated optics

    NASA Astrophysics Data System (ADS)

    Song, Junyeob; Zhou, Wei

    2017-02-01

    Plasmonic nanocavities can control light flows and enhance light-mater interactions at subwavelength scale, and thus can potentially be used as nanoscale components in integrated optics systems either for passive optical coupling, or for active optical modulation and emission. In this work, we investigated a new type of multilayered metal-insulator optical nanocavities that can support multiple localized plasmon resonances with ultra-small mode volumes. The total number of resonance peaks and their resonance wavelengths can be freely and accurately controlled by simple geometric design rules. Multi-resonance plasmonic nanocavities can serve as a nanoscale wavelength-multiplexed optical components in integrated optics systems, such as optical couplers, light emitters, nanolasers, optical sensors, and optical modulators.

  13. Alcohol consumption during adolescence is associated with reduced grey matter volumes.

    PubMed

    Heikkinen, Noora; Niskanen, Eini; Könönen, Mervi; Tolmunen, Tommi; Kekkonen, Virve; Kivimäki, Petri; Tanila, Heikki; Laukkanen, Eila; Vanninen, Ritva

    2017-04-01

    Cognitive impairment has been associated with excessive alcohol use, but its neural basis is poorly understood. Chronic excessive alcohol use in adolescence may lead to neuronal loss and volumetric changes in the brain. Our objective was to compare the grey matter volumes of heavy- and light-drinking adolescents. This was a longitudinal study: heavy-drinking adolescents without an alcohol use disorder and their light-drinking controls were followed-up for 10 years using questionnaires at three time-points. Magnetic resonance imaging was conducted at the last time-point. The area near Kuopio University Hospital, Finland. The 62 participants were aged 22-28 years and included 35 alcohol users and 27 controls who had been followed-up for approximately 10 years. Alcohol use was measured by the Alcohol Use Disorders Identification Test (AUDIT)-C at three time-points during 10 years. Participants were selected based on their AUDIT-C score. Magnetic resonance imaging was conducted at the last time-point. Grey matter volume was determined and compared between heavy- and light-drinking groups using voxel-based morphometry on three-dimensional T1-weighted magnetic resonance images using predefined regions of interest and a threshold of P < 0.05, with small volume correction applied on cluster level. Grey matter volumes were significantly smaller among heavy-drinking participants in the bilateral anterior cingulate cortex, right orbitofrontal and frontopolar cortex, right superior temporal gyrus and right insular cortex compared to the control group (P < 0.05, family-wise error-corrected cluster level). Excessive alcohol use during adolescence appears to be associated with an abnormal development of the brain grey matter. Moreover, the structural changes detected in the insula of alcohol users may reflect a reduced sensitivity to alcohol's negative subjective effects. © 2016 Society for the Study of Addiction.

  14. Lighting design for globally illuminated volume rendering.

    PubMed

    Zhang, Yubo; Ma, Kwan-Liu

    2013-12-01

    With the evolution of graphics hardware, high quality global illumination becomes available for real-time volume rendering. Compared to local illumination, global illumination can produce realistic shading effects which are closer to real world scenes, and has proven useful for enhancing volume data visualization to enable better depth and shape perception. However, setting up optimal lighting could be a nontrivial task for average users. There were lighting design works for volume visualization but they did not consider global light transportation. In this paper, we present a lighting design method for volume visualization employing global illumination. The resulting system takes into account view and transfer-function dependent content of the volume data to automatically generate an optimized three-point lighting environment. Our method fully exploits the back light which is not used by previous volume visualization systems. By also including global shadow and multiple scattering, our lighting system can effectively enhance the depth and shape perception of volumetric features of interest. In addition, we propose an automatic tone mapping operator which recovers visual details from overexposed areas while maintaining sufficient contrast in the dark areas. We show that our method is effective for visualizing volume datasets with complex structures. The structural information is more clearly and correctly presented under the automatically generated light sources.

  15. Root restriction: A tool for improving volume utilization efficiency in bioregenerative life-support systems

    NASA Astrophysics Data System (ADS)

    Graham, Thomas; Wheeler, Raymond

    2016-06-01

    The objective of this study was to evaluate root restriction as a tool to increase volume utilization efficiency in spaceflight crop production systems. Bell pepper plants (Capsicum annuum cv. California Wonder) were grown under restricted rooting volume conditions in controlled environment chambers. The rooting volume was restricted to 500 ml and 60 ml in a preliminary trial, and 1500 ml (large), 500 ml (medium), and 250 ml (small) for a full fruiting trial. To reduce the possible confounding effects of water and nutrient restrictions, care was taken to ensure an even and consistent soil moisture throughout the study, with plants being watered/fertilized several times daily with a low concentration soluble fertilizer solution. Root restriction resulted in a general reduction in biomass production, height, leaf area, and transpiration rate; however, the fruit production was not significantly reduced in the root restricted plants under the employed environmental and horticultural conditions. There was a 21% reduction in total height and a 23% reduction in overall crown diameter between the large and small pot size in the fruiting study. Data from the fruiting trial were used to estimate potential volume utilization efficiency improvements for edible biomass in a fixed production volume. For fixed lighting and rooting hardware situations, the majority of improvement from root restriction was in the reduction of canopy area per plant, while height reductions could also improve volume utilization efficiency in high stacked or vertical agricultural systems.

  16. Root restriction: A tool for improving volume utilization efficiency in bioregenerative life-support systems.

    PubMed

    Graham, Thomas; Wheeler, Raymond

    2016-06-01

    The objective of this study was to evaluate root restriction as a tool to increase volume utilization efficiency in spaceflight crop production systems. Bell pepper plants (Capsicum annuum cv. California Wonder) were grown under restricted rooting volume conditions in controlled environment chambers. The rooting volume was restricted to 500ml and 60ml in a preliminary trial, and 1500ml (large), 500ml (medium), and 250ml (small) for a full fruiting trial. To reduce the possible confounding effects of water and nutrient restrictions, care was taken to ensure an even and consistent soil moisture throughout the study, with plants being watered/fertilized several times daily with a low concentration soluble fertilizer solution. Root restriction resulted in a general reduction in biomass production, height, leaf area, and transpiration rate; however, the fruit production was not significantly reduced in the root restricted plants under the employed environmental and horticultural conditions. There was a 21% reduction in total height and a 23% reduction in overall crown diameter between the large and small pot size in the fruiting study. Data from the fruiting trial were used to estimate potential volume utilization efficiency improvements for edible biomass in a fixed production volume. For fixed lighting and rooting hardware situations, the majority of improvement from root restriction was in the reduction of canopy area per plant, while height reductions could also improve volume utilization efficiency in high stacked or vertical agricultural systems. Copyright © 2016 The Committee on Space Research (COSPAR). All rights reserved.

  17. Nonlocal optical effects on the Goos-Hänchen shift at an interface of a composite material of metallic nanoparticles.

    PubMed

    Huang, J H; Leung, P T

    2013-07-01

    We present a theoretical study on the nonlocal optical effects on the Goos-Hänchen (GH) shift of reflected light from a composite material of metallic nanoparticles (MNPs). Using different nonlocal effective medium models, it is observed that such effects can be significant for small MNP of sizes down to a few nanometers. For small metallic volume fractions, the composite behaves like dielectric and the nonlocal effects lead to significant different Brewster angles, at which large negative GH shifts take place. For larger volume fractions or shorter wavelengths, the composite behaves more like metals and the nonlocal effects also lead to different Brewster angles but at values close to grazing incidence. These results will have significant implications in the application of different effective medium models for the characterization of these nanometallic composites when the MNPs are down to a few nanometers in size.

  18. Bar coded retroreflective target

    DOEpatents

    Vann, Charles S.

    2000-01-01

    This small, inexpensive, non-contact laser sensor can detect the location of a retroreflective target in a relatively large volume and up to six degrees of position. The tracker's laser beam is formed into a plane of light which is swept across the space of interest. When the beam illuminates the retroreflector, some of the light returns to the tracker. The intensity, angle, and time of the return beam is measured to calculate the three dimensional location of the target. With three retroreflectors on the target, the locations of three points on the target are measured, enabling the calculation of all six degrees of target position. Until now, devices for three-dimensional tracking of objects in a large volume have been heavy, large, and very expensive. Because of the simplicity and unique characteristics of this tracker, it is capable of three-dimensional tracking of one to several objects in a large volume, yet it is compact, light-weight, and relatively inexpensive. Alternatively, a tracker produces a diverging laser beam which is directed towards a fixed position, and senses when a retroreflective target enters the fixed field of view. An optically bar coded target can be read by the tracker to provide information about the target. The target can be formed of a ball lens with a bar code on one end. As the target moves through the field, the ball lens causes the laser beam to scan across the bar code.

  19. Miniature Laser Tracker

    DOEpatents

    Vann, Charles S.

    2003-09-09

    This small, inexpensive, non-contact laser sensor can detect the location of a retroreflective target in a relatively large volume and up to six degrees of position. The tracker's laser beam is formed into a plane of light which is swept across the space of interest. When the beam illuminates the retroreflector, some of the light returns to the tracker. The intensity, angle, and time of the return beam is measured to calculate the three dimensional location of the target. With three retroreflectors on the target, the locations of three points on the target are measured, enabling the calculation of all six degrees of target position. Until now, devices for three-dimensional tracking of objects in a large volume have been heavy, large, and very expensive. Because of the simplicity and unique characteristics of this tracker, it is capable of three-dimensional tracking of one to several objects in a large volume, yet it is compact, light-weight, and relatively inexpensive. Alternatively, a tracker produces a diverging laser beam which is directed towards a fixed position, and senses when a retroreflective target enters the fixed field of view. An optically bar coded target can be read by the tracker to provide information about the target. The target can be formed of a ball lens with a bar code on one end. As the target moves through the field, the ball lens causes the laser beam to scan across the bar code.

  20. Transparency of an instantaneously created electron-positron-photon plasma

    NASA Astrophysics Data System (ADS)

    Bégué, D.; Vereshchagin, G. V.

    2014-03-01

    The problem of the expansion of a relativistic plasma generated when a large amount of energy is released in a small volume has been considered by many authors. We use the analytical solution of Bisnovatyi-Kogan and Murzina for the spherically symmetric relativistic expansion. The light curves and the spectra from transparency of an electron-positron-photon plasma are obtained. We compare our results with the work of Goodman.

  1. Low emittance electron storage rings

    NASA Astrophysics Data System (ADS)

    Levichev, E. B.

    2018-01-01

    Low-emittance electron (positron) beams are essential for synchrotron light sources, linear collider damping rings, and circular Crab Waist colliders. In this review, the principles and methods of emittance minimization are discussed, prospects for developing relativistic electron storage rings with small beam phase volume are assessed, and problems related to emittance minimization are examined together with their possible solutions. The special features and engineering implementation aspects of various facilities are briefly reviewed.

  2. Hand-Held Photometer for Instant On-Spot Quantification of Nucleic Acids, Proteins, and Cells.

    PubMed

    Li, Shi-Hao; Jain, Abhinav; Tscharntke, Timo; Arnold, Tobias; Trau, Dieter W

    2018-02-20

    This paper presents a novel hand-held photometer, termed "Photopette", for on-spot absorbance measurements of biochemical analytes. The Photopette is a multicomponent, highly portable device with an overall weight of 160 g, which fits within 202 mm × 47 mm × 42 mm. Designed in the form factor of a micropipette, Photopette integrates a photodiode detector with light emitting diodes (LEDs) to form a highly customizable photometer which supports a wide variety of applications within the wavelengths between 260 and 1050 nm. A dual-purpose disposable reflective tip was designed to act as a sample holder and a light-reflecting system, which is in stark contrast to the operation of mainstream spectrophotometers and photometers. Small volume analytes may be measured with low sample loss using this proprietary CuveTip. A user-friendly software application running on smart devices was developed to control and read the values from Photopette via a low-energy Bluetooth link. This one-step strategy allows measurements on-spot without sample transfer, minimizing cross-contamination and human error. The results reported in this paper demonstrate Photopette's great potential to quantify DNA, direct protein, and cell density directly within the laminar flow hood. Results are compared with a Nanodrop 2000c spectrophotometer, a mainstream spectrophotometer for small-volume measurements.

  3. Disconnected-Sea Quarks Contribution to Nucleon Electromagnetic Form Factors

    NASA Astrophysics Data System (ADS)

    Sufian, Raza Sabbir

    We present comprehensive analysis of the light and strange disconnected-sea quarks contribution to the nucleon electric and magnetic form factors. The lattice QCD estimates of strange quark magnetic moment GsM (0) = -0.064(14)(09) microN and the mean squared charge radius E = -0.0043(16)(14) fm2 are more precise than any existing experimental measurements and other lattice calculations. The lattice QCD calculation includes ensembles across several lattice volumes and lattice spacings with one of the ensembles at the physical pion mass. We have performed a simultaneous chiral, infinite volume, and continuum extrapolation in a global fit to calculate results in the continuum limit. We find that the combined light-sea and strange quarks contribution to the nucleon magnetic moment is -0.022(11)(09) microN and to the nucleon mean square charge radius is -0.019(05)(05) fm 2. The most important outcome of this lattice QCD calculation is that while the combined light-sea and strange quarks contribution to the nucleon magnetic moment is small at about 1%, a negative 2.5(9)% contribution to the proton charge radius and a relatively larger positive 16.3(6.1)% contribution to the neutron charge radius come from the sea quarks in the nucleon. For the first time, by performing global fits, we also give predictions of the light-sea and strange quarks contributions to the nucleon electric and magnetic form factors at the physical point and in the continuum and infinite volume limits in the momentum transfer range of 0 ≤ Q2 ≤ 0.5 GeV2.

  4. Phototoxic action of light emitting diode in the in vitro viability of Trichophyton rubrum.

    PubMed

    Amorim, José Cláudio Faria; Soares, Betania Maria; Alves, Orley Araújo; Ferreira, Marcus Vinícius Lucas; Sousa, Gerdal Roberto; Silveira, Lívio de Barros; Piancastelli, André Costa Cruz; Pinotti, Marcos

    2012-01-01

    Trichophyton rubrum is the most common agent of superficial mycosis of the skin and nails causing long lasting infections and high recurrence rates. Current treatment drawbacks involve topical medications not being able to reach the nail bed at therapeutic concentrations, systemic antifungal drugs failing to eradicate the fungus before the nails are renewed, severe side effects and selection of resistant fungal isolates. Photodynamic therapy (PDT) has been a promising alternative to conventional treatments. This study evaluated the in vitro effectiveness of toluidine blue O (TBO) irradiated by Light emitting diode (LED) in the reduction of T. rubrum viability. The fungal inoculums' was prepared and exposed to different TBO concentrations and energy densities of Light emitting diode for evaluate the T. rubrum sensibility to PDT and production effect fungicidal after photodynamic treatment. In addition, the profiles of the area and volume of the irradiated fungal suspensions were also investigated. A small reduction, in vitro, of fungal cells was observed after exposition to 100 µM toluidine blue O irradiated by 18 J/cm² Light emitting diode. Fungicidal effect occurred after 25 µM toluidine blue O irradiation by Light emitting diode with energy density of 72 J/cm². The analysis showed that the area and volume irradiated by the Light emitting diode were 52.2 mm² and 413.70 mm³, respectively. The results allowed to conclude that Photodynamic therapy using Light emitting diode under these experimental conditions is a possible alternative approach to inhibit in vitro T. rubrum and may be a promising new treatment for dermatophytosis caused by this fungus.

  5. Circadian rhythm of mechanically mediated differentiation of osteoblasts

    NASA Technical Reports Server (NTRS)

    Roberts, W. E.; Mozsary, P. G.; Klingler, E.

    1984-01-01

    The differential of osteoblasts in response to orthodontic pressure in the periodontal ligament of the maxillary-first-molar periodontal ligaments of 12-h-light/dark-entrained 7-wk-old male Simonsen outbred rats is measured by (H-3)-Thymidine nuclear-volume morphometry (Roberts et al., 1983) at hourly intervals throughout the circadian cycle. The results are presented in graphs and discussed. Preosteoblast large nuclei (D-cells) are found to synthesize DNA mainly in light and to divide in the following dark period, while small-nucleus osteoprogenitors (A-cells) synthesize in darkness and divide in light. These findings are seen as consistent with a model in which the sequence of proliferation and differentiation requires at least 60 h (five 12-h periods) and the shift from A to D cells lasts about 19 h.

  6. Bottom-up production of meta-atoms for optical magnetism in visible and NIR light

    NASA Astrophysics Data System (ADS)

    Barois, Philippe; Ponsinet, Virginie; Baron, Alexandre; Richetti, Philippe

    2018-02-01

    Many unusual optical properties of metamaterials arise from the magnetic response of engineered structures of sub-wavelength size (meta-atoms) exposed to light. The top-down approach whereby engineered nanostructure of well-defined morphology are engraved on a surface proved to be successful for the generation of strong optical magnetism. It faces however the limitations of high cost and small active area in visible light where nanometre resolution is needed. The bottom-up approach whereby the fabrication metamaterials of large volume or large area results from the combination of nanochemitry and self-assembly techniques may constitute a cost-effective alternative. This approach nevertheless requires the large-scale production of functional building-blocks (meta-atoms) bearing a strong magnetic optical response. We propose in this paper a few tracks that lead to the large scale synthesis of magnetic metamaterials operating in visible or near IR light.

  7. Pressure, O2, and CO2, in aquatic Closed Ecological Systems

    NASA Astrophysics Data System (ADS)

    Taub, Frieda B.; McLaskey, Anna K.

    2013-03-01

    Pressure increased during net photosynthetic O2 production in the light and decreased during respiratory O2 uptake during the dark in aquatic Closed Ecological Systems (CESs) with small head gas volumes. Because most CO2 will be in the liquid phase as bicarbonate and carbonate anions, and CO2 is more soluble than O2, volumes of gaseous CO2 and gaseous O2 will not change in a compensatory manner, leading to the development of pressure. Pressure increases were greatest with nutrient rich medium with NaHCO3 as the carbon source. With more dilute media, pressure was greatest with NaHCO3, and less with cellulose or no-added carbon. Without adequate turbulence, pressure measurements lagged dissolved O2 concentrations by several hours and dark respiration would have been especially underestimated in our systems (250-1000 ml). With adequate turbulence (rotary shaker), pressure measurements and dissolved O2 concentrations generally agreed during lights on/off cycles, but O2 measurements provided more detail. At 20 °C, 29.9 times as much O2 will distribute into the gas phase as in the liquid, per unit volume, as a result of the limited solubility of O2 in water and according to Henry's Law. Thus even a small head gas volume can contain more O2 than a larger volume of water. When both dissolved and gaseous O2 and CO2 are summed, the changes in Total O2 and CO2 are in relatively close agreement when NaHCO3 is the carbon source. These findings disprove an assumption made in some of Taub's earlier research that aquatic CESs would remain at approximately atmospheric pressure because approximately equal molar quantities of O2 and CO2 would exchange during photosynthesis and respiration; this assumption neglected the distribution of O2 between water and gas phases. High pressures can occur when NaHCO3 is the carbon source in nutrient rich media and if head-gas volumes are small relative to the liquid volume; e.g., one "worse case" condition developed 800 mm Hg above atmospheric pressure and broke the glass container. Plastic screw cap closures are likely to leak at high pressures and should not be assumed to seal unless tested at appropriate pressures. Pressure can be reduced by having larger head-gas volumes and using less concentrated nutrient solutions. It is important that pressure changes be considered for both safety and closure, and if total O2 is used as the measure of net photosynthesis and respiration, the O2 in the gas phase must be added to the dissolved O2.

  8. Flexible and Lightweight Fuel Cell with High Specific Power Density.

    PubMed

    Ning, Fandi; He, Xudong; Shen, Yangbin; Jin, Hehua; Li, Qingwen; Li, Da; Li, Shuping; Zhan, Yulu; Du, Ying; Jiang, Jingjing; Yang, Hui; Zhou, Xiaochun

    2017-06-27

    Flexible devices have been attracting great attention recently due to their numerous advantages. But the energy densities of current energy sources are still not high enough to support flexible devices for a satisfactory length of time. Although proton exchange membrane fuel cells (PEMFCs) do have a high-energy density, traditional PEMFCs are usually too heavy, rigid, and bulky to be used in flexible devices. In this research, we successfully invented a light and flexible air-breathing PEMFC by using a new design of PEMFC and a flexible composite electrode. The flexible air-breathing PEMFC with 1 × 1 cm 2 working area can be as light as 0.065 g and as thin as 0.22 mm. This new PEMFC exhibits an amazing specific volume power density as high as 5190 W L -1 , which is much higher than traditional (air-breathing) PEMFCs. Also outstanding is that the flexible PEMFC retains 89.1% of its original performance after being bent 600 times, and it retains its original performance after being dropped five times from a height of 30 m. Moreover, the research has demonstrated that when stacked, the flexible PEMFCs are also useful in mobile applications such as mobile phones. Therefore, our research shows that PEMFCs can be made light, flexible, and suitable for applications in flexible devices. These innovative flexible PEMFCs may also notably advance the progress in the PEMFC field, because flexible PEMFCs can achieve high specific power density with small size, small volume, low weight, and much lower cost; they are also much easier to mass produce.

  9. Nonlinear Fano-Resonant Dielectric Metasurfaces

    DOE PAGES

    Yang, Yuanmu; Wang, Wenyi; Boulesbaa, Abdelaziz; ...

    2015-10-26

    Strong nonlinear light matter interaction is highly sought-after for a variety of applications including lasing and all-optical light modulation. Recently, resonant plasmonic structures have been considered promising candidates for enhancing nonlinear optical processes due to their ability to greatly enhance the optical near-field; however, their small mode volumes prevent the inherently large nonlinear susceptibility of the metal from being efficiently exploited. We present an alternative approach that utilizes a Fano-resonant silicon metasurface. The metasurface results in strong near-field enhancement within the volume of the silicon resonator while minimizing two photon absorption. Here, we measure a third harmonic generation enhancement factormore » of 1.5 105 with respect to an unpatterned silicon film and an absolute conversion efficiency of 1.2 10 6 with a peak pump intensity of 3.2 GW cm 2. The enhanced nonlinearity, combined with a sharp linear transmittance spectrum, results in transmission modulation with a modulation depth of 36%. Finally, the modulation mechanism is studied by pump probe experiments« less

  10. SPED light sheet microscopy: fast mapping of biological system structure and function

    PubMed Central

    Tomer, Raju; Lovett-Barron, Matthew; Kauvar, Isaac; Andalman, Aaron; Burns, Vanessa M.; Sankaran, Sethuraman; Grosenick, Logan; Broxton, Michael; Yang, Samuel; Deisseroth, Karl

    2016-01-01

    The goal of understanding living nervous systems has driven interest in high-speed and large field-of-view volumetric imaging at cellular resolution. Light-sheet microscopy approaches have emerged for cellular-resolution functional brain imaging in small organisms such as larval zebrafish, but remain fundamentally limited in speed. Here we have developed SPED light sheet microscopy, which combines large volumetric field-of-view via an extended depth of field with the optical sectioning of light sheet microscopy, thereby eliminating the need to physically scan detection objectives for volumetric imaging. SPED enables scanning of thousands of volumes-per-second, limited only by camera acquisition rate, through the harnessing of optical mechanisms that normally result in unwanted spherical aberrations. We demonstrate capabilities of SPED microscopy by performing fast sub-cellular resolution imaging of CLARITY mouse brains and cellular-resolution volumetric Ca2+ imaging of entire zebrafish nervous systems. Together, SPED light sheet methods enable high-speed cellular-resolution volumetric mapping of biological system structure and function. PMID:26687363

  11. Compact Plasma Accelerator for Micropropulsion Applications

    NASA Technical Reports Server (NTRS)

    Foster, John E.

    2001-01-01

    There is a need for a low power, light-weight (compact), high specific impulse electric propulsion device to satisfy mission requirements for microsatellite (1 to 20 kg) class missions. Satisfying these requirements entails addressing the general problem of generating a sufficiently dense plasma within a relatively small volume and then accelerating it. In the work presented here, the feasibility of utilizing a magnetic cusp to generate a dense plasma over small length scales of order 1 mm is investigated. This approach could potentially mitigate scaling issues associated with conventional ion thruster plasma containment schemes. Plume and discharge characteristics were documented using a Faraday probe and a retarding potential analyzer.

  12. Modulation transfer function measurement technique for small-pixel detectors

    NASA Technical Reports Server (NTRS)

    Marchywka, Mike; Socker, Dennis G.

    1992-01-01

    A modulation transfer function (MTF) measurement technique suitable for large-format, small-pixel detector characterization has been investigated. A volume interference grating is used as a test image instead of the bar or sine wave target images normally used. This technique permits a high-contrast, large-area, sinusoidal intensity distribution to illuminate the device being tested, avoiding the need to deconvolve raw data with imaging system characteristics. A high-confidence MTF result at spatial frequencies near 200 cycles/mm is obtained. We present results at several visible light wavelengths with a 6.8-micron-pixel CCD. Pixel response functions are derived from the MTF results.

  13. Digital stereophotogrammetry based on circular markers and zooming cameras: evaluation of a method for 3D analysis of small motions in orthopaedic research

    PubMed Central

    2011-01-01

    Background Orthopaedic research projects focusing on small displacements in a small measurement volume require a radiation free, three dimensional motion analysis system. A stereophotogrammetrical motion analysis system can track wireless, small, light-weight markers attached to the objects. Thereby the disturbance of the measured objects through the marker tracking can be kept at minimum. The purpose of this study was to develop and evaluate a non-position fixed compact motion analysis system configured for a small measurement volume and able to zoom while tracking small round flat markers in respect to a fiducial marker which was used for the camera pose estimation. Methods The system consisted of two web cameras and the fiducial marker placed in front of them. The markers to track were black circles on a white background. The algorithm to detect a centre of the projected circle on the image plane was described and applied. In order to evaluate the accuracy (mean measurement error) and precision (standard deviation of the measurement error) of the optical measurement system, two experiments were performed: 1) inter-marker distance measurement and 2) marker displacement measurement. Results The first experiment of the 10 mm distances measurement showed a total accuracy of 0.0086 mm and precision of ± 0.1002 mm. In the second experiment, translations from 0.5 mm to 5 mm were measured with total accuracy of 0.0038 mm and precision of ± 0.0461 mm. The rotations of 2.25° amount were measured with the entire accuracy of 0.058° and the precision was of ± 0.172°. Conclusions The description of the non-proprietary measurement device with very good levels of accuracy and precision may provide opportunities for new, cost effective applications of stereophotogrammetrical analysis in musculoskeletal research projects, focusing on kinematics of small displacements in a small measurement volume. PMID:21284867

  14. Protein aggregation studied by forward light scattering and light transmission analysis

    NASA Astrophysics Data System (ADS)

    Penzkofer, A.; Shirdel, J.; Zirak, P.; Breitkreuz, H.; Wolf, E.

    2007-12-01

    The aggregation of the circadian blue-light photo-receptor cryptochrome from Drosophila melanogaster (dCry) is studied by transmission and forward light scattering measurement in the protein transparent wavelength region. The light scattering in forward direction is caused by Rayleigh scattering which is proportional to the degree of aggregation. The light transmission through the samples in the transparent region is reduced by Mie light scattering in all directions. It depends on the degree of aggregation and the monomer volume fill factor of the aggregates (less total scattering with decreasing monomer volume fill factor of protein globule) allowing a distinction between tightly packed protein aggregation (monomer volume fill factor 1) and loosely packed protein aggregation (monomer volume fill factor less than 1). An increase in aggregation with temperature, concentration, and blue-light exposure is observed. At a temperature of 4 °C and a protein concentration of less than 0.135 mM no dCry aggregation was observed, while at 24 °C and 0.327 mM gelation occurred (loosely packed aggregates occupying the whole solution volume).

  15. Propulsion and Power Supplies for Unmanned Vehicles. Volume I. Engines for Small Propeller-Driven RPVS

    DTIC Science & Technology

    1977-11-01

    residual unbaiance. Mass production experience and availability of rotary piston engines -type WANKEL- refer basically to the automobile industry...production air cooled automobile engine in standard form can be ruled out on a specific weight basis. 4. In modified form, as used in many light aircr: Ct...the air cooled automobile engine appears to be a possibility. Availability, lcw initial cost; and good specific fuel consumption could make the unit

  16. Microvolume index of refraction determinations by interferometric backscatter

    NASA Astrophysics Data System (ADS)

    Bornhop, Darryl J.

    1995-06-01

    A new method has been applied to the determination of fluid bulk properties in small detection volumes. Through the use of an unfocused He-Ne laser beam and a cylindrical tube of capillary dimensions, relative refractive-index measurements are possible. The backscattered light from the illumination of a tube of capillary dimensions produces an interference pattern that is spatially defined and that contains information related to the bulk properties of the fluid contained in the tube. Positional changes in the intensity-modulated beam profile (interference fringes) are directly related to the refractive index of the fluid in the tube. The determination of dn/n at the 10-7 level is possible in probe volumes of 350 pL. The technique has been applied to tubes as small as 75 mu m inner diameter and as large as 1.0 mm inner diameter. No modification of the simple optical bench is required for facilitating the determination of refractive index for the complete range of tube diameters.

  17. Formation and characterization of simulated small droplet icing clouds

    NASA Technical Reports Server (NTRS)

    Ingebo, R. D.

    1986-01-01

    Two pneumatic two-fluid atomizers operating at high liquid and gas pressures produced water sprays that simulated small droplet clouds for use in studying icing effects on aircraft performance. To measure median volume diameter, MVD or D sub v.5, of small droplet water sprays, a scattered-light scanning instrument was developed. Drop size data agreed fairly well with calculated values at water and nitrogen pressures of 60 and 20 psig, respectively, and at water and nitrogen pressures of 250 and 100 psig, respectively, but not very well at intermediate values of water and nitrogen pressure. MVD data were correlated with D sub 0, W sub N, and W sub w, i.e., orifice diameter, nitrogen, and water flowrate, respectively, to give the expression for MVD in microns.

  18. Photoactivated Composite Biomaterial for Soft Tissue Restoration in Rodents and in Humans

    PubMed Central

    Nahas, Zayna; Reid, Branden; Coburn, Jeannine M.; Axelman, Joyce; Chae, Jemin J.; Guo, Qiongyu; Trow, Robert; Thomas, Andrew; Hou, Zhipeng; Lichtsteiner, Serge; Sutton, Damon; Matheson, Christine; Walker, Patricia; David, Nathaniel; Mori, Susumu; Taube, Janis M.; Elisseeff, Jennifer H.

    2015-01-01

    Soft tissue reconstruction often requires multiple surgical procedures that can result in scars and disfiguration. Facial soft tissue reconstruction represents a clinical challenge because even subtle deformities can severely affect an individual’s social and psychological function. We therefore developed a biosynthetic soft tissue replacement composed of poly(ethylene glycol) (PEG) and hyaluronic acid (HA) that can be injected and photocrosslinked in situ with transdermal light exposure. Modulating the ratio of synthetic to biological polymer allowed us to tune implant elasticity and volume persistence. In a small-animal model, implanted photocrosslinked PEG-HA showed a dose-dependent relationship between increasing PEG concentration and enhanced implant volume persistence. In direct comparison with commercial HA injections, the PEG-HA implants maintained significantly greater average volumes and heights. Reversibility of the implant volume was achieved with hyaluronidase injection. Pilot clinical testing in human patients confirmed the feasibility of the transdermal photocrosslinking approach for implantation in abdomen soft tissue, although an inflammatory response was observed surrounding some of the materials. PMID:21795587

  19. Field lens multiplexing in holographic 3D displays by using Bragg diffraction based volume gratings

    NASA Astrophysics Data System (ADS)

    Fütterer, G.

    2016-11-01

    Applications, which can profit from holographic 3D displays, are the visualization of 3D data, computer-integrated manufacturing, 3D teleconferencing and mobile infotainment. However, one problem of holographic 3D displays, which are e.g. based on space bandwidth limited reconstruction of wave segments, is to realize a small form factor. Another problem is to provide a reasonable large volume for the user placement, which means to provide an acceptable freedom of movement. Both problems should be solved without decreasing the image quality of virtual and real object points, which are generated within the 3D display volume. A diffractive optical design using thick hologram gratings, which can be referred to as Bragg diffraction based volume gratings, can provide a small form factor and high definition natural viewing experience of 3D objects. A large collimated wave can be provided by an anamorphic backlight unit. The complex valued spatial light modulator add local curvatures to the wave field he is illuminated with. The modulated wave field is focused onto to the user plane by using a volume grating based field lens. Active type liquid crystal gratings provide 1D fine tracking of approximately +/- 8° deg. Diffractive multiplex has to be implemented for each color and for a set of focus functions providing coarse tracking. Boundary conditions of the diffractive multiplexing are explained. This is done in regards to the display layout and by using the coupled wave theory (CWT). Aspects of diffractive cross talk and its suppression will be discussed including longitudinal apodized volume gratings.

  20. Ultrasound modulation of bioluminescence generated inside a turbid medium

    NASA Astrophysics Data System (ADS)

    Ahmad, Junaid; Jayet, Baptiste; Hill, Philip J.; Mather, Melissa L.; Dehghani, Hamid; Morgan, Stephen P.

    2017-03-01

    In vivo bioluminescence imaging (BLI) has poor spatial resolution owing to strong light scattering by tissue, which also affects quantitative accuracy. This paper proposes a hybrid acousto-optic imaging platform that images bioluminescence modulated at ultrasound (US) frequency inside an optically scattering medium. This produces an US modulated light within the tissue that reduces the effects of light scattering and improves the spatial resolution. The system consists of a continuously excited 3.5 MHz US transducer applied to a tissue like phantom of known optical properties embedded with bio-or chemiluminescent sources that are used to mimic in vivo experiments. Scanning US over the turbid medium modulates the luminescent sources deep inside tissue at several US scan points. These modulated signals are recorded by a photomultiplier tube and lock-in detection to generate a 1D profile. Indeed, high frequency US enables small focal volume to improve spatial resolution, but this leads to lower signal-to-noise ratio. First experimental results show that US enables localization of a small luminescent source (around 2 mm wide) deep ( 20 mm) inside a tissue phantom having a scattering coefficient of 80 cm-1. Two sources separated by 10 mm could be resolved 20 mm inside a chicken breast.

  1. 40 CFR Appendix 7 to Subpart A of... - Determination of the Amount of Non-Aqueous Drilling Fluid (NAF) Base Fluid From Drill Cuttings by...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... multiplying the density of the small volume NAF-cuttings discharges (ρsvd) times the volume of the small...-cuttings discharges (kg) ρsvd = density of the small volume NAF-cuttings discharges (kg/bbl) VSVD = volume of the small volume NAF-cuttings discharges (bbl) The density of the small volume NAF-cuttings...

  2. 40 CFR Appendix 7 to Subpart A of... - Determination of the Amount of Non-Aqueous Drilling Fluid (NAF) Base Fluid From Drill Cuttings by...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... multiplying the density of the small volume NAF-cuttings discharges (ρsvd) times the volume of the small...-cuttings discharges (kg) ρsvd = density of the small volume NAF-cuttings discharges (kg/bbl) VSVD = volume of the small volume NAF-cuttings discharges (bbl) The density of the small volume NAF-cuttings...

  3. 40 CFR Appendix 7 to Subpart A of... - Determination of the Amount of Non-Aqueous Drilling Fluid (NAF) Base Fluid From Drill Cuttings by...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... multiplying the density of the small volume NAF-cuttings discharges (ρsvd) times the volume of the small...-cuttings discharges (kg) ρsvd = density of the small volume NAF-cuttings discharges (kg/bbl) VSVD = volume of the small volume NAF-cuttings discharges (bbl) The density of the small volume NAF-cuttings...

  4. Total internal reflection and dynamic light scattering microscopy of gels

    NASA Astrophysics Data System (ADS)

    Gregor, Brian F.

    Two different techniques which apply optical microscopy in novel ways to the study of biological systems and materials were built and applied to several samples. The first is a system for adapting the well-known technique of dynamic light scattering (DLS) to an optical microscope. This can detect and scatter light from very small volumes, as compared to standard DLS which studies light scattering from volumes 1000x larger. The small scattering volume also allows for the observation of nonergodic dynamics in appropriate samples. Porcine gastric mucin (PGM) forms a gel at low pH which lines the epithelial cell layer and acts as a protective barrier against the acidic stomach environment. The dynamics and microscopic viscosity of PGM at different pH levels is studied using polystyrene microspheres as tracer particles. The microscopic viscosity and microrheological properties of the commercial basement membrane Matrigel are also studied with this instrument. Matrigel is frequently used to culture cells and its properties remain poorly determined. Well-characterized and purely synthetic Matrigel substitutes will need to have the correct rheological and morphological characteristics. The second instrument designed and built is a microscope which uses an interferometry technique to achieve an improvement in resolution 2.5x better in one dimension than the Abbe diffraction limit. The technique is based upon the interference of the evanescent field generated on the surface of a prism by a laser in a total internal reflection geometry. The enhanced resolution is demonstrated with fluorescent samples. Additionally. Raman imaging microscopy is demonstrated using the evanescent field in resonant and non-resonant samples, although attempts at applying the enhanced resolution technique to the Raman images were ultimately unsuccessful. Applications of this instrument include high resolution imaging of cell membranes and macroscopic structures in gels and proteins. Finally, a third section incorporating previous research on simulations of complex fluids is included. Two dimensional simulations of oil, water, and surfactant mixtures were computed with a lattice gas method. The simulated systems were randomly mixed and then the temperature was quenched to a predetermined point. Spontaneous micellization is observed for a narrow range of temperature quenches, and the overall growth rate of macroscopic structure is found to follow a Vogel-Fulcher growth law.

  5. 60-GHz integrated-circuit high data rate quadriphase shift keying exciter and modulator

    NASA Technical Reports Server (NTRS)

    Grote, A.; Chang, K.

    1984-01-01

    An integrated-circuit quadriphase shift keying (QPSK) exciter and modulator have demonstrated excellent performance directly modulating a carrier frequency of 60 GHz with an output phase error of less than 3 degrees and maximum amplitude error of 0.5 dB. The circuit consists of a 60-GHz Gunn VCO phase-locked to a low-frequency reference source, a 4th subharmonic mixer, and a QPSK modlator packaged into a small volume of 1.8 x 2.5 x 0.35 in. The use of microstrip has the advantages of small size, light-weight, and low-cost fabrication. The unit has the potential for multigigabit data rate applications.

  6. Recent advances in chemiluminescence detection coupled with capillary electrophoresis and microchip capillary electrophoresis.

    PubMed

    Liu, Yuxuan; Huang, Xiangyi; Ren, Jicun

    2016-01-01

    CE is an ideal analytical method for extremely volume-limited biological microenvironments. However, the small injection volume makes it a challenge to achieve highly sensitive detection. Chemiluminescence (CL) detection is characterized by providing low background with excellent sensitivity because of requiring no light source. The coupling of CL with CE and MCE has become a powerful analytical method. So far, this method has been widely applied to chemical analysis, bioassay, drug analysis, and environment analysis. In this review, we first introduce some developments for CE-CL and MCE-CL systems, and then put the emphasis on the applications in the last 10 years. Finally, we discuss the future prospects. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Defense Small Business Innovation Research Program (SBIR). Volume 3. Air Force Abstracts of Phase 1 Awards from FY 1988 SBIR Solicitation

    DTIC Science & Technology

    1989-05-01

    THE TARGET DOPPLER FREQUENCIES. ADAPTIVE SENSORS INC 216 PICO BLVD - STE 8 SANTA MONICA, CA 90405 CONTRACT NUMBER: JOHN S BAILEY TITLE: SPATIALLY...APPLIED RESEARCH ASSOCS INC 4300 SAN MATEO BLVD NE - STE A220 ALBUQUERQUE, NM 87110 CONTRACT NUMBER: FRANK A MAESTAS TITLE: PARAMETRIC ANALYSIS OF EXPLOSIVE...VERIFIED THROUGH SUBSCALE FABRICATION AND TEST. AV DYNAMICS INC 825 MYRTLE AVE MONROVIA, CA 91016 CONTRACT NUMBER: DR P B S LISSAMAN TITLE: LIGHT WEIGHT

  8. Development of a Compact & Easy-to-Use 3-D Camera for High Speed Turbulent Flow Fields

    DTIC Science & Technology

    2013-12-05

    resolved. Also, in the case of a single camera system, the use of an aperture greatly reduces the amount of collected light. The combination of these...a study on wall-bounded turbulence [Sheng_2006]. Nevertheless, these techniques are limited to small measurement volumes, while maintaining a high...It has also been adapted to kHz rates using high-speed cameras for aeroacoustic studies (see Violato et al. [17, 18]. Tomo-PIV, however, has some

  9. Hybrid single quantum well InP/Si nanobeam lasers for silicon photonics.

    PubMed

    Fegadolli, William S; Kim, Se-Heon; Postigo, Pablo Aitor; Scherer, Axel

    2013-11-15

    We report on a hybrid InP/Si photonic crystal nanobeam laser emitting at 1578 nm with a low threshold power of ~14.7 μW. Laser gain is provided from a single InAsP quantum well embedded in a 155 nm InP layer bonded on a standard silicon-on-insulator wafer. This miniaturized nanolaser, with an extremely small modal volume of 0.375(λ/n)(3), is a promising and efficient light source for silicon photonics.

  10. Non-resonant Nanoscale Extreme Light Confinement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Subramania, Ganapathi Subramanian; Huber, Dale L.

    2014-09-01

    A wide spectrum of photonics activities Sandia is engaged in such as solid state lighting, photovoltaics, infrared imaging and sensing, quantum sources, rely on nanoscale or ultrasubwavelength light-matter interactions (LMI). The fundamental understanding in confining electromagnetic power and enhancing electric fields into ever smaller volumes is key to creating next generation devices for these programs. The prevailing view is that a resonant interaction (e.g. in microcavities or surface-plasmon polaritions) is necessary to achieve the necessary light confinement for absorption or emission enhancement. Here we propose new paradigm that is non-resonant and therefore broadband and can achieve light confinement and fieldmore » enhancement in extremely small areas [~(λ/500)^2 ]. The proposal is based on a theoretical work[1] performed at Sandia. The paradigm structure consists of a periodic arrangement of connected small and large rectangular slits etched into a metal film named double-groove (DG) structure. The degree of electric field enhancement and power confinement can be controlled by the geometry of the structure. The key operational principle is attributed to quasistatic response of the metal electrons to the incoming electromagnetic field that enables non-resonant broadband behavior. For this exploratory LDRD we have fabricated some test double groove structures to enable verification of quasistatic electronic response in the mid IR through IR optical spectroscopy. We have addressed some processing challenges in DG structure fabrication to enable future design of complex sensor and detector geometries that can utilize its non-resonant field enhancement capabilities.].« less

  11. Development of online NIR urine analyzing system based on AOTF

    NASA Astrophysics Data System (ADS)

    Wan, Feng; Sun, Zhendong; Li, Xiaoxia

    2006-09-01

    In this paper, some key techniques on development of on-line MR urine analyzing system based on AOTF (Acousto - Optics Tunable Filter) are introduced. Problems about designing the optical system including collimation of incident light and working distance (the shortest distance for separating incident light and diffracted light) are analyzed and researched. DDS (Direct Digital Synthesizer) controlled by microprocessor is used to realize the wavelength scan. The experiment results show that this MR urine analyzing system based on. AOTF has 10000 - 4000cm -1 wavelength range and O.3ms wavelength transfer rate. Compare with the conventional Fourier Transform NIP. spectrophotometer for analyzing multi-components in urine, this system features low cost, small volume and on-line measurement function. Unscrambler software (multivariate statistical software by CAMO Inc. Norway) is selected as the software for processing the data. This system can realize on line quantitative analysis of protein, urea and creatinine in urine.

  12. Decreasing photobleaching by silver island films: application to muscle⋆

    PubMed Central

    Muthu, P.; Gryczynski, I.; Gryczynski, Z.; Talent, J.; Akopova, I.; Jain, K.; Borejdo, J.

    2007-01-01

    Recently it has become possible to study interactions between proteins at the level of single molecules. This requires collecting data from an extremely small volume, small enough to contain one molecule—typically of the order of attoliters (10−18 L). Collection of data from such a small volume with sufficiently high signal-to-noise ratio requires that the rate of photon detection per molecule be high. This calls for a large illuminating light flux, which in turn leads to rapid photobleaching of the fluorophores that are labeling the proteins. To decrease photobleaching, we measured fluorescence from a sample placed on coverslips coated with silver island films (SIF). SIF reduce photobleaching because they enhance fluorescence brightness and significantly decrease fluorescence lifetime. Increase in the brightness effectively decreases photobleaching because illumination can be attenuated to obtain the same fluorescence intensity. Decrease of lifetime decreases photobleaching because short lifetime minimizes the probability of oxygen attack while the fluorophore is in the excited state. The decrease of photobleaching was demonstrated in skeletal muscle. Myofibrils were labeled lightly with rhodamine–phalloidin, placed on coverslips coated with SIF, illuminated by total internal reflection, and observed through a confocal aperture. We show that SIF causes the intensity of phalloidin fluorescence to increase 4- to 5- fold and its fluorescence lifetime to decrease on average 23-fold. As a consequence, the rate of photobleaching of four or five molecules of actin of a myofibril on Olympus coverslips coated with SIF decreased at least 30-fold in comparison with photobleaching on an uncoated coverslip. Significant decrease of photobleaching makes the measurement of signal from a single cross-bridge of contracting muscle feasible. PMID:17531183

  13. Guidelines for freeway lighting curfews.

    DOT National Transportation Integrated Search

    2012-10-01

    Roadway lighting is provided on selected highways to improve the visibility of the nighttime environment. : Roadway lighting is typically warranted on the basis of the daily traffic volume. However, in the earlymorning : hours, the traffic volumes ma...

  14. Multi-purpose hydrogen isotopes separation plant design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boniface, H.A.; Gnanapragasam, N.V.; Ryland, D.K.

    2015-03-15

    There is a potential interest at AECL's Chalk River Laboratories to remove tritium from moderately tritiated light water and to reclaim tritiated, downgraded heavy water. With only a few limitations, a single CECE (Combined Electrolysis and Catalytic Exchange) process configuration can be designed to remove tritium from heavy water or light water and upgrade heavy water. Such a design would have some restrictions on the nature of the feed-stock and tritium product, but could produce essentially tritium-free light or heavy water that is chemically pure. The extracted tritium is produced as a small quantity of tritiated heavy water. The overallmore » plant capacity is fixed by the total amount of electrolysis and volume of catalyst. In this proposal, with 60 kA of electrolysis a throughput of 15 kg*h{sup -1} light water for detritiation, about 4 kg*h{sup -1} of heavy water for detritiation and about 27 kg*h{sup -1} of 98% heavy water for upgrading can be processed. Such a plant requires about 1,000 liters of AECL isotope exchange catalyst. The general design features and details of this multi-purpose CECE process are described in this paper, based on some practical choices of design criteria. In addition, we outline the small differences that must be accommodated and some compromises that must be made to make the plant capable of such flexible operation. (authors)« less

  15. Frequency-domain optical tomographic image reconstruction algorithm with the simplified spherical harmonics (SP3) light propagation model.

    PubMed

    Kim, Hyun Keol; Montejo, Ludguier D; Jia, Jingfei; Hielscher, Andreas H

    2017-06-01

    We introduce here the finite volume formulation of the frequency-domain simplified spherical harmonics model with n -th order absorption coefficients (FD-SP N ) that approximates the frequency-domain equation of radiative transfer (FD-ERT). We then present the FD-SP N based reconstruction algorithm that recovers absorption and scattering coefficients in biological tissue. The FD-SP N model with 3 rd order absorption coefficient (i.e., FD-SP 3 ) is used as a forward model to solve the inverse problem. The FD-SP 3 is discretized with a node-centered finite volume scheme and solved with a restarted generalized minimum residual (GMRES) algorithm. The absorption and scattering coefficients are retrieved using a limited-memory Broyden-Fletcher-Goldfarb-Shanno (L-BFGS) algorithm. Finally, the forward and inverse algorithms are evaluated using numerical phantoms with optical properties and size that mimic small-volume tissue such as finger joints and small animals. The forward results show that the FD-SP 3 model approximates the FD-ERT (S 12 ) solution within relatively high accuracy; the average error in the phase (<3.7%) and the amplitude (<7.1%) of the partial current at the boundary are reported. From the inverse results we find that the absorption and scattering coefficient maps are more accurately reconstructed with the SP 3 model than those with the SP 1 model. Therefore, this work shows that the FD-SP 3 is an efficient model for optical tomographic imaging of small-volume media with non-diffuse properties both in terms of computational time and accuracy as it requires significantly lower CPU time than the FD-ERT (S 12 ) and also it is more accurate than the FD-SP 1 .

  16. Salt-induced aggregation and fusion of dioctadecyldimethylammonium chloride and sodium dihexadecylphosphate vesicles.

    PubMed Central

    Carmona-Ribeiro, A M; Chaimovich, H

    1986-01-01

    Small dioctadecyldimethylammonium chloride (DODAC) vesicles prepared by sonication fuse upon addition of NaCl as detected by several methods (electron microscopy, trapped volume determinations, temperature-dependent phase transition curves, and osmometer behavior. In contrast, small sodium dihexadecyl phosphate (DHP) vesicles mainly aggregate upon NaCl addition as shown by electron microscopy and the lack of osmometer behavior. Scatter-derived absorbance changes of small and large DODAC or DHP vesicles as a function of time after salt addition were obtained for a range of NaCl or amphiphile concentration. These changes were interpreted in accordance with a phenomenological model based upon fundamental light-scattering laws and simple geometrical considerations. Short-range hydration repulsion between DODAC (or DHP) vesicles is possibly the main energy barrier for the fusion process. Images FIGURE 2 FIGURE 9 PMID:3779002

  17. Microfluidic reactors for visible-light photocatalytic water purification assisted with thermolysis

    PubMed Central

    Wang, Ning; Tan, Furui; Wan, Li; Wu, Mengchun

    2014-01-01

    Photocatalytic water purification using visible light is under intense research in the hope to use sunlight efficiently, but the conventional bulk reactors are slow and complicated. This paper presents an integrated microfluidic planar reactor for visible-light photocatalysis with the merits of fine flow control, short reaction time, small sample volume, and long photocatalyst durability. One additional feature is that it enables one to use both the light and the heat energy of the light source simultaneously. The reactor consists of a BiVO4-coated glass as the substrate, a blank glass slide as the cover, and a UV-curable adhesive layer as the spacer and sealant. A blue light emitting diode panel (footprint 10 mm × 10 mm) is mounted on the microreactor to provide uniform irradiation over the whole reactor chamber, ensuring optimal utilization of the photons and easy adjustments of the light intensity and the reaction temperature. This microreactor may provide a versatile platform for studying the photocatalysis under combined conditions such as different temperatures, different light intensities, and different flow rates. Moreover, the microreactor demonstrates significant photodegradation with a reaction time of about 10 s, much shorter than typically a few hours using the bulk reactors, showing its potential as a rapid kit for characterization of photocatalyst performance. PMID:25584117

  18. REFLECTION AND REFRACTION, VOLUME 2.

    ERIC Educational Resources Information Center

    KLAUS, DAVID J.; AND OTHERS

    THIS VOLUME 2 OF A TWO-VOLUME SET PROVIDES AUTOINSTRUCTION IN PHYSICS. THE UNITS COVERED IN THIS VOLUME ARE (1) REFLECTION OF LIGHT, (2) PHOTOMETRY, (3) POLARIZATION, (4) REFRACTION OF LIGHT, (5) SNELL'S LAW, (6) LENSES, FOCUS, AND FOCAL POINTS, (7) IMAGE FORMATION, AND (8) ABERRATIONS, THE EYE, AND MAGNIFICATION. THE INTRODUCTION AND UNITS ON…

  19. Tomographic sensing and localization of fluorescently labeled circulating cells in mice in vivo

    NASA Astrophysics Data System (ADS)

    Zettergren, Eric; Swamy, Tushar; Runnels, Judith; Lin, Charles P.; Niedre, Mark

    2012-07-01

    Sensing and enumeration of specific types of circulating cells in small animals is an important problem in many areas of biomedical research. Microscopy-based fluorescence in vivo flow cytometry methods have been developed previously, but these are typically limited to sampling of very small blood volumes, so that very rare circulating cells may escape detection. Recently, we described the development of a ‘diffuse fluorescence flow cytometer’ (DFFC) that allows sampling of much larger blood vessels and therefore circulating blood volumes in the hindlimb, forelimb or tail of a mouse. In this work, we extend this concept by developing and validating a method to tomographically localize circulating fluorescently labeled cells in the cross section of a tissue simulating optical flow phantom and mouse limb. This was achieved using two modulated light sources and an array of six fiber-coupled detectors that allowed rapid, high-sensitivity acquisition of full tomographic data sets at 10 Hz. These were reconstructed into two-dimensional cross-sectional images using Monte Carlo models of light propagation and the randomized algebraic reconstruction technique. We were able to obtain continuous images of moving cells in the sample cross section with 0.5 mm accuracy or better. We first demonstrated this concept in limb-mimicking optical flow photons with up to four flow channels, and then in the tails of mice with fluorescently labeled multiple myeloma cells. This approach increases the overall diagnostic utility of our DFFC instrument.

  20. An Integrated Micro- and Macroarchitectural Analysis of the Drosophila Brain by Computer-Assisted Serial Section Electron Microscopy

    PubMed Central

    Cardona, Albert; Saalfeld, Stephan; Preibisch, Stephan; Schmid, Benjamin; Cheng, Anchi; Pulokas, Jim; Tomancak, Pavel; Hartenstein, Volker

    2010-01-01

    The analysis of microcircuitry (the connectivity at the level of individual neuronal processes and synapses), which is indispensable for our understanding of brain function, is based on serial transmission electron microscopy (TEM) or one of its modern variants. Due to technical limitations, most previous studies that used serial TEM recorded relatively small stacks of individual neurons. As a result, our knowledge of microcircuitry in any nervous system is very limited. We applied the software package TrakEM2 to reconstruct neuronal microcircuitry from TEM sections of a small brain, the early larval brain of Drosophila melanogaster. TrakEM2 enables us to embed the analysis of the TEM image volumes at the microcircuit level into a light microscopically derived neuro-anatomical framework, by registering confocal stacks containing sparsely labeled neural structures with the TEM image volume. We imaged two sets of serial TEM sections of the Drosophila first instar larval brain neuropile and one ventral nerve cord segment, and here report our first results pertaining to Drosophila brain microcircuitry. Terminal neurites fall into a small number of generic classes termed globular, varicose, axiform, and dendritiform. Globular and varicose neurites have large diameter segments that carry almost exclusively presynaptic sites. Dendritiform neurites are thin, highly branched processes that are almost exclusively postsynaptic. Due to the high branching density of dendritiform fibers and the fact that synapses are polyadic, neurites are highly interconnected even within small neuropile volumes. We describe the network motifs most frequently encountered in the Drosophila neuropile. Our study introduces an approach towards a comprehensive anatomical reconstruction of neuronal microcircuitry and delivers microcircuitry comparisons between vertebrate and insect neuropile. PMID:20957184

  1. "big" Divisor D3/D7 Swiss-Cheese Phenomenology

    NASA Astrophysics Data System (ADS)

    Misra, Aalok

    We review progress made over the past couple of years in the field of Swiss-Cheese Phenomenology involving a mobile spacetime filling D3-brane and stack(s) of fluxed D7-branes wrapping the "big" (as opposed to the "small") divisor in (the orientifold of (a) Swiss-Cheese Calabi-Yau. The topics reviewed include reconciliation of large volume cosmology and phenomenology, evaluation of soft supersymmetry breaking parameters, one-loop RG-flow equations' solutions for scalar masses, obtaining fermionic (possibly first two generations' quarks/leptons) mass scales in the {O}(MeV--GeV)-regime as well as (first two generations') neutrino masses (and their one-loop RG flow) of around an eV. The heavy sparticles and the light fermions indicate the possibility of "split SUSY" large volume scenario.

  2. Riemann sum method for non-line-of-sight ultraviolet communication in noncoplanar geometry

    NASA Astrophysics Data System (ADS)

    Song, Peng; Zhou, Xianli; Song, Fei; Zhao, Taifei; Li, Yunhong

    2017-12-01

    The non-line-of-sight ultraviolet (UV) communication relies on the scattering common volume, however, it is difficult to carry out the triple integral operation of the scattering common volume. Based on UV single-scattering propagation theory and the spherical coordinate, we propose to use the Riemann sum method (RSM) to analyze the link path loss (PL) of UV communication system in noncoplanar geometries, and carried out related simulations. In addition, an outdoor testbed using UV light-emitting diode was set up to provide support for the validity of the RSM. When the elevation angles of the transmitter or the receiver are small, using RSM, the channel PL and temporal response of UV communication systems can be effectively and efficiently calculated. It is useful in UV embedded system design.

  3. The diagnosis and treatment of brain metastases in EGFR mutant lung cancer.

    PubMed

    Minchom, Anna; Yu, Ken C; Bhosle, Jaishree; O'Brien, Mary

    2014-05-01

    The epidemiology of non-small-cell lung cancer (NSCLC) has changed with a new pattern of disease emerging - a form of adenocarcinoma in mostly younger female patients, who are never or light smokers and more frequently in East Asian populations. Description of EGF receptor (EGFR) mutations has allowed new management strategies to evolve. Oral targeted therapies have broadened the treatment options in the advanced setting with the potential for periods of long term response. The brain is a common site of metastases with EGFR mutated lung cancer typically displaying asymptomatic, small volume, multiple lesions that respond to treatment. We explore the role of local and system therapies for brain metastases in this disease including the role of EGFR inhibitors.

  4. Two-Dimensional Photonic Crystals for Sensitive Microscale Chemical and Biochemical Sensing

    PubMed Central

    Miller, Benjamin L.

    2015-01-01

    Photonic crystals – optical devices able to respond to changes in the refractive index of a small volume of space – are an emerging class of label-free chemical-and bio-sensors. This review focuses on one class of photonic crystal, in which light is confined to a patterned planar material layer of sub-wavelength thickness. These devices are small (on the order of tens to 100s of microns square), suitable for incorporation into lab-on-a-chip systems, and in theory can provide exceptional sensitivity. We introduce the defining characteristics and basic operation of two-dimensional photonic crystal sensors, describe variations of their basic design geometry, and summarize reported detection results from chemical and biological sensing experiments. PMID:25563402

  5. Reduce volume of head-up display by image stitching

    NASA Astrophysics Data System (ADS)

    Chiu, Yi-Feng; Su, Guo-Dung J.

    2016-09-01

    Head-up Display (HUD) is a safety feature for automobile drivers. Although there have been some HUD systems in commercial product already, their images are too small to show assistance information. Another problem, the volume of HUD is too large. We proposed a HUD including micro-projectors, rear-projection screen, microlens array (MLA) and the light source is 28 mm x 14 mm realized a 200 mm x 100 mm image in 3 meters from drivers. We want to use the MLA to reduce the volume by virtual image stitching. We design the HUD's package dimensions is 12 cm x 12 cm x 9 cm. It is able to show speed, map-navigation and night vision information. We used Liquid Crystal Display (LCD) as our image source due to its brighter image output required and the minimum volume occupancy. The MLA is a multi aperture system. The proposed MLA consists of many optical channels each transmitting a segment of the whole field of view. The design of the system provides the stitching of the partial images, so that we can see the whole virtual image.

  6. New Method for Quantitation of Lipid Droplet Volume From Light Microscopic Images With an Application to Determination of PAT Protein Density on the Droplet Surface.

    PubMed

    Dejgaard, Selma Y; Presley, John F

    2018-06-01

    Determination of lipid droplet (LD) volume has depended on direct measurement of the diameter of individual LDs, which is not possible when LDs are small or closely apposed. To overcome this problem, we describe a new method in which a volume-fluorescence relationship is determined from automated analysis of calibration samples containing well-resolved LDs. This relationship is then used to estimate total cellular droplet volume in experimental samples, where the LDs need not be individually resolved, or to determine the volumes of individual LDs. We describe quantitatively the effects of various factors, including image noise, LD crowding, and variation in LD composition on the accuracy of this method. We then demonstrate this method by utilizing it to address a scientifically interesting question, to determine the density of green fluorescent protein (GFP)-tagged Perilipin-Adipocyte-Tail (PAT) proteins on the LD surface. We find that PAT proteins cover only a minority of the LD surface, consistent with models in which they primarily serve as scaffolds for binding of regulatory proteins and enzymes, but inconsistent with models in which their major function is to sterically block access to the droplet surface.

  7. The tools of PDT: light sources and devices. Can they help in getting better therapeutic results?

    NASA Astrophysics Data System (ADS)

    Boucher, Didier

    2011-08-01

    PDT is a drug and device therapy using photosensitizing drugs activated by laser light, for tissue ablation. PDT light sources must deliver wavelengths matching the absorption of photosensitizers' compound without any side thermal effect. According to applications, these sources need to be: - pled to relatively small optical fibres so as to bring the light energy, of specific wavelength, inside of the body (gastroenterology, head & neck, urology, pneumology), - coupled to a slit lamp adapter to transmit the light to the eye (AMD) - or allow a direct illumination of tissues when large areas must be treated (dermatology). But they also need to be user-friendly with limited investment and installation costs. So as to achieve the required effects, several light sources are available and will be used but practical and economical reasons have limited the number and types of these sources. For PDT oncology applications, besides dermatology, it has also been necessary to develop specific light delivery systems based on optical fibres. These devices allow the treatment: - of circular lumens such as oesophagus, bile ducts, lungs - of solid volumes such as prostate, pancreas - of surfaces such as in head and neck - of empty volumes such as bladder, uterus, cervix. Due to the variety of these treatments, a full family of sources has been developed from original sophisticated costly lasers to more recent easy-to-use diode laser systems. The aim of this presentation is to present the actual state of the art of actual available PDT tools, analyze their qualities and weaknesses, analyze the consequences of a good and/or bad choice or good and/or bad utilization on the quality of the therapeutic results and resulting side effects. It will also evaluate the short and medium term developments of new tools and their effect on the development of the therapy including economical aspects.

  8. Technical Review of the Laboratory Biosphere Closed Ecological System Facility

    NASA Astrophysics Data System (ADS)

    Dempster, W.; van Thillo, M.; Alling, A.; Allen, J.; Silverstone, S.; Nelson, M.

    The "Laboratory Biosphere", a new closed ecological system facility in Santa Fe, New Mexico (USA) has been constructed and became operational in May 2002. Built and operated by the Global Ecotechnics consortium (Biosphere Technologies and Biosphere Foundation with Biospheric Design Inc., and the Institute of Ecotechnics), the research apparatus for intensive crop growth, biogeochemical cycle dynamics and recycling of inedible crop biomass comprises a sealed cylindrical steel chamber and attached variable volume chamber (lung) to prevent pressures caused by the expansion and contraction of the contained air. The cylindrical growing chamber is 3.7m (12 feet) long and 3.7m (12 foot) diameter, giving an internal volume of 34 m3 (1200 ft 3 ). The two crop growth beds cover 5.5 m2, with a soil depth of 0.3m (12 inches), with 12 x 1000 watt high-pressure sodium lights capable of variable lighting of 40-70 mol per m2 per day. A small soil bed reactor in the chamber can be activated to help with metabolism of chamber trace gases. The volume of the attached variable volume chamber (lung) can range between 0-11 m3 (0-400 ft 3 ). Evapotranspired and soil leachate water are collected, combined and recycled to water the planting beds. Sampling ports enable testing of water quality of leachate, condensate and irrigation water. Visual inspection windows provide views of the entire interior and growing beds. The chamber is also outfitted with an airlock to minimize air exchange when people enter and work in the chamber. Continuous sensors include atmospheric CO2 and oxygen, temperature, humidity, soil moisture, light level and water levels in reservoirs. Both "sniffer" (air ports) and "sipper" (water ports) will enable collection of water or air samples for detailed analysis. This paper reports on the development of this new soil-based bioregenerative life support closed system apparatus and its technical challenges and capabilities.

  9. A measurement of the holographic minimum-observable beam branching ratio in the FERMILAB 15-ft bubble chamber

    NASA Astrophysics Data System (ADS)

    Aderholz, M.; Aggarwal, M. M.; Akbari, H.; Allport, P. P.; Badyal, S. K.; Ballagh, H. C.; Barth, M.; Baton, J. P.; Bingham, H. H.; Bjelkhagen, H.; Brucker, E. B.; Burnstein, R. A.; Campbell, J. R.; Cence, R. J.; Chatterjee, T. K.; Clayton, E. F.; Corrigan, G.; Coutures, C.; DeProspo, D.; Devanand; De Wolf, E. A.; Faulkner, P. J. W.; Foeth, H.; Fretter, W. B.; Geissler, K.; Gupta, V. K.; Hanlon, J.; Harigel, G. G.; Harris, F. A.; Hawkins, J.; Jabiol, M. A.; Jacques, P.; Jones, G. T.; Jones, M. D.; Kafka, T.; Kalelkar, M.; Kasper, P.; Kohli, J. M.; Koller, E. L.; Krawiec, R. J.; Lauko, M.; Lys, J. E.; Marage, P.; Milburn, R. H.; Miller, D. B.; Mittra, I. S.; Mobayyen, M. M.; Moreels, J.; Morrison, D. R. O.; Myatt, G.; Naon, R.; Napier, A.; Naylor, P.; Neveu, M.; Passmore, D.; Peters, M. W.; Peterson, V. Z.; Plano, R.; Rao, N. K.; Rubin, H. A.; Sacton, J.; Sambyal, S. S.; Schmitz, N.; Schneps, J.; Sekulin, R. L.; Sewell, S.; Singh, J. B.; Smart, W.; Stamer, P.; Varvell, K. E.; Verluyten, L.; Voyvodic, L.; Wachsmuth, H.; Wainstein, S.; Williams, W.; Willocq, S.; Yost, G. P.; E-632 Collaboration

    1999-01-01

    Holography has been used successfully in combination with conventional optics for the first time in a large cryogenic bubble chamber, the 15-foot bubble chamber at Fermilab, during a physics run. The innovative system combined the reference beam with the object beam, irradiating a conical volume of ˜1.4 m 3. Bubble tracks from neutrino interactions with a width of ˜120 μm have been recorded with good contrast. The ratio of intensities of the object light to the reference light striking the film is called the beam branching ratio. We obtained in our experiment an exceedingly small minimum-observable ratio of (0.54±0.21)×10 -7. The technology has the potential for a wide range of applications.

  10. Fiber-Optic Chemical Sensors and Fiber-Optic Bio-Sensors.

    PubMed

    Pospíšilová, Marie; Kuncová, Gabriela; Trögl, Josef

    2015-09-30

    This review summarizes principles and current stage of development of fiber-optic chemical sensors (FOCS) and biosensors (FOBS). Fiber optic sensor (FOS) systems use the ability of optical fibers (OF) to guide the light in the spectral range from ultraviolet (UV) (180 nm) up to middle infrared (IR) (10 μm) and modulation of guided light by the parameters of the surrounding environment of the OF core. The introduction of OF in the sensor systems has brought advantages such as measurement in flammable and explosive environments, immunity to electrical noises, miniaturization, geometrical flexibility, measurement of small sample volumes, remote sensing in inaccessible sites or harsh environments and multi-sensing. The review comprises briefly the theory of OF elaborated for sensors, techniques of fabrications and analytical results reached with fiber-optic chemical and biological sensors.

  11. Stability of Gadolinium-Doped Liquid Organic Scintillators

    NASA Astrophysics Data System (ADS)

    Gromov, M. B.; Kuznetsov, D. S.; Murchenko, A. E.; Novikova, G. Ya.; Obinyakov, B. A.; Oralbaev, A. Yu.; Plakitina, K. V.; Skorokhvatov, M. D.; Sukhotin, S. V.; Chepurnov, A. S.; Etenko, A. V.

    2018-03-01

    The technology of preparing a linear-alkylbenzene-based gadolinium-doped liquid organic scintillator (Gd-LOS) as a target material in reactor antineutrino detectors has been developed. Results of longterm measurements of the light yield of Gd-LOS in contact with acryl and stainless steel are presented, which confirm the compatibility of Gd-LOS with these materials. The measurements were performed for two otherwise identical LOS detectors only differing in wall materials of the sensitive volume: acryl versus stainless steel. The results of measurements over about one year showed almost the same, relatively small decreases in the light yield of both detectors. It is concluded that both structural materials can be used in detector parts contacting with Gd-doped scintillator. Such a long-term parallel comparative test was carried out for the first time.

  12. Volumetric bioimaging based on light field microscopy with temporal focusing illumination

    NASA Astrophysics Data System (ADS)

    Hsu, Feng-Chun; Sie, Yong Da; Lai, Feng-Jie; Chen, Shean-Jen

    2018-02-01

    Light field technique at a single shot can get the whole volume image of observed sample. Therefore, the original frame rate of the optical system can be taken as the volumetric image rate. For dynamically imaging whole micron-scale biosample, a light field microscope with temporal focusing illumination has been developed. In the light field microscope, the f-number of the microlens array (MLA) is adopted to match that of the objective; hence, the subimages via adjacent lenslets do not overlay each other. A three-dimensional (3D) deconvolution algorithm is utilized to deblur the out-of-focusing part. Conventional light field microscopy (LFM) illuminates whole volume sample even noninteresting parts; nevertheless, whole volume excitation causes even more damage on bio-sample and also increase the background noise from the out of range. Therefore, temporal focusing is integrated into the light field microscope for selecting the illumination volume. Herein, a slit on the back focal plane of the objective is utilized to control the axial excitation confinement for selecting the illumination volume. As a result, the developed light field microscope with the temporal focusing multiphoton illumination (TFMPI) can reconstruct 3D images within the selected volume, and the lateral resolution approaches to the theoretical value. Furthermore, the 3D Brownian motion of two-micron fluorescent beads is observed as the criterion of dynamic sample. With superior signal-to-noise ratio and less damage to tissue, the microscope is potential to provide volumetric imaging for vivo sample.

  13. 40 CFR 86.1826-01 - Assigned deterioration factors for small volume manufacturers and small volume test groups.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... durability groups) that is equipped with unproven emission control systems. (v) The manufacturer must... small volume manufacturers and small volume test groups. 86.1826-01 Section 86.1826-01 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW...

  14. 40 CFR 86.1826-01 - Assigned deterioration factors for small volume manufacturers and small volume test groups.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... durability groups) that is equipped with unproven emission control systems. (v) The manufacturer must... small volume manufacturers and small volume test groups. 86.1826-01 Section 86.1826-01 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW...

  15. 40 CFR 86.1826-01 - Assigned deterioration factors for small volume manufacturers and small volume test groups.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... durability groups) that is equipped with unproven emission control systems. (v) The manufacturer must... small volume manufacturers and small volume test groups. 86.1826-01 Section 86.1826-01 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW...

  16. 40 CFR 86.1826-01 - Assigned deterioration factors for small volume manufacturers and small volume test groups.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... durability groups) that is equipped with unproven emission control systems. (v) The manufacturer must... small volume manufacturers and small volume test groups. 86.1826-01 Section 86.1826-01 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW...

  17. Optical, physical, and chemical properties of springtime aerosol over Barrow Alaska in 2008

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shantz, Nicole C.; Gultepe, Ismail; Andrews, Elisabeth

    2014-03-06

    Airborne observations from four flights during the 2008 Indirect and Semi-Direct Aerosol Campaign (ISDAC) are used to examine some cloud-free optical, physical, and chemical properties of aerosol particles in the springtime Arctic troposphere. The number concentrations of particles larger than 0.12 μm (Na>120), important for light extinction and cloud droplet formation, ranged from 15 to 2260 cm -3, with the higher Na>120 cases dominated by measurements from two flights of long-range transported biomass burning (BB) aerosols. The two other flights examined here document a relatively clean aerosol and an Arctic Haze aerosol impacted by larger particles largely composed of dust.more » For observations from the cleaner case and the BB cases, the particle light scattering coefficients at low relative humidity (RH<20%) increased nonlinearly with increasing Na>120, driven mostly by an increase in mean sizes of particles with increasing Na>120 (BB cases). For those three cases, particle light absorption coefficients also increased nonlinearly with increasing Na>120 and linearly with increasing submicron particle volume concentration. In addition to black carbon, brown carbon was estimated to have increased light absorption coefficients by 27% (450 nm wavelength) and 14% (550 nm) in the BB cases. For the case with strong dust influence, the absorption relative to submicron particle volume was small compared with the other cases. There was a slight gradient of Passive Cavity Aerosol Spectrometer Probe (PCASP) mean volume diameter (MVD) towards smaller sizes with increasing height, which suggests more scavenging of the more elevated particles, consistent with a typically longer lifetime of particles higher in the atmosphere. However, in approximately 10% of the cases, the MVD increased (>0.4 μm) with increasing altitude, suggesting transport of larger fine particle mass (possibly coarse particle mass) at high levels over the Arctic. This may be because of transport of larger particles at higher elevations and relatively slow deposition to the surface.« less

  18. Sea quarks contribution to the nucleon magnetic moment and charge radius at the physical point

    NASA Astrophysics Data System (ADS)

    Sufian, Raza Sabbir; Yang, Yi-Bo; Liang, Jian; Draper, Terrence; Liu, Keh-Fei; χ QCD Collaboration

    2017-12-01

    We report a comprehensive analysis of the light and strange disconnected-sea quarks contribution to the nucleon magnetic moment, charge radius, and the electric and magnetic form factors. The lattice QCD calculation includes ensembles across several lattice volumes and lattice spacings with one of the ensembles at the physical pion mass. We adopt a model-independent extrapolation of the nucleon magnetic moment and the charge radius. We have performed a simultaneous chiral, infinite volume, and continuum extrapolation in a global fit to calculate results in the continuum limit. We find that the combined light and strange disconnected-sea quarks contribution to the nucleon magnetic moment is μM(DI )=-0.022 (11 )(09 ) μN and to the nucleon mean square charge radius is ⟨r2⟩E(DI ) =-0.019 (05 )(05 ) fm2 which is about 1 /3 of the difference between the ⟨rp2⟩E of electron-proton scattering and that of a muonic atom and so cannot be ignored in obtaining the proton charge radius in the lattice QCD calculation. The most important outcome of this lattice QCD calculation is that while the combined light-sea and strange quarks contribution to the nucleon magnetic moment is small at about 1%, a negative 2.5(9)% contribution to the proton mean square charge radius and a relatively larger positive 16.3(6.1)% contribution to the neutron mean square charge radius come from the sea quarks in the nucleon. For the first time, by performing global fits, we also give predictions of the light and strange disconnected-sea quarks contributions to the nucleon electric and magnetic form factors at the physical point and in the continuum and infinite volume limits in the momentum transfer range of 0 ≤Q2≤0.5 GeV2 .

  19. A portable single-sided magnet system for remote NMR measurements of pulmonary function.

    PubMed

    Dabaghyan, Mikayel; Muradyan, Iga; Hrovat, Alan; Butler, James; Frederick, Eric; Zhou, Feng; Kyriazis, Angelos; Hardin, Charles; Patz, Samuel; Hrovat, Mirko

    2014-12-01

    In this work, we report initial results from a light-weight, low field magnetic resonance device designed to make relative pulmonary density measurements at the bedside. The development of this device necessarily involves special considerations for the magnet, RF and data acquisition schemes as well as a careful analysis of what is needed to provide useful information in the ICU. A homogeneous field region is created remotely from the surface of the magnet such that when the magnet is placed against the chest, an NMR signal is measured from a small volume in the lung. In order to achieve portability, one must trade off field strength and therefore spatial resolution. We report initial measurements from a ping-pong ball size region in the lung as a function of lung volume. As expected, we measured decreased signal at larger lung volumes since lung density decreases with increasing lung volume. Using a CPMG sequence with ΔTE=3.5 ms and a 20 echo train, a signal to noise ratio ~1100 was obtained from an 8.8mT planar magnet after signal averaging for 43 s. This is the first demonstration of NMR measurements made on a human lung with a light-weight planar NMR device. We argue that very low spatial resolution measurements of different lobar lung regions will provide useful diagnostic information for clinicians treating Acute Respiratory Distress Syndrome as clinicians want to avoid ventilator pressures that cause either lung over distension (too much pressure) or lung collapse (too little pressure). Copyright © 2014 John Wiley & Sons, Ltd.

  20. A portable single-sided magnet system for remote NMR measurements of pulmonary function

    PubMed Central

    Mikayel, Dabaghyan; Iga, Muradyan; James, Butler; Eric, Frederick; Feng, Zhou; Angelos, Kyriazis; Charles, Hardin; Samuel, Patz; Mirko, Hrovat

    2014-01-01

    In this work, we report initial results from a light-weight, low field magnetic resonance device designed to make relative pulmonary density measurements at the bedside. The development of this device necessarily involves special considerations for the magnet, RF and data acquisition schemes as well as a careful analysis of what is needed to provide useful information in the ICU. A homogeneous field region is created remotely from the surface of the magnet such that when the magnet is placed against the chest, an NMR signal is measured from a small volume in the lung. In order to achieve portability, one must trade off field strength and therefore spatial resolution. We report initial measurements from a ping-pong ball size region in the lung as a function of lung volume. As expected, we measured decreased signal at larger lung volumes since lung density decreases with increasing lung volume. Using a CPMG sequence with ΔTE=3.5 ms and a 20 echo train, a signal to noise ratio ~1100 was obtained from an 8.8mT planar magnet after signal averaging for 43 s. This is the first demonstration of NMR measurements made on a human lung with a light-weight planar NMR device. We argue that very low spatial resolution measurements of different lobar lung regions will provide useful diagnostic information for clinicians treating Acute Respiratory Distress Syndrome as clinicians want to avoid ventilator pressures that cause either lung over distension (too much pressure) or lung collapse (too little pressure). PMID:24953556

  1. Estimating pore and cement volumes in thin section

    USGS Publications Warehouse

    Halley, R.B.

    1978-01-01

    Point count estimates of pore, grain and cement volumes from thin sections are inaccurate, often by more than 100 percent, even though they may be surprisingly precise (reproducibility + or - 3 percent). Errors are produced by: 1) inclusion of submicroscopic pore space within solid volume and 2) edge effects caused by grain curvature within a 30-micron thick thin section. Submicroscopic porosity may be measured by various physical tests or may be visually estimated from scanning electron micrographs. Edge error takes the form of an envelope around grains and increases with decreasing grain size and sorting, increasing grain irregularity and tighter grain packing. Cements are greatly involved in edge error because of their position at grain peripheries and their generally small grain size. Edge error is minimized by methods which reduce the thickness of the sample viewed during point counting. Methods which effectively reduce thickness include use of ultra-thin thin sections or acetate peels, point counting in reflected light, or carefully focusing and counting on the upper surface of the thin section.

  2. Design of compact freeform lens for application specific Light-Emitting Diode packaging.

    PubMed

    Wang, Kai; Chen, Fei; Liu, Zongyuan; Luo, Xiaobing; Liu, Sheng

    2010-01-18

    Application specific LED packaging (ASLP) is an emerging technology for high performance LED lighting. We introduced a practical design method of compact freeform lens for extended sources used in ASLP. A new ASLP for road lighting was successfully obtained by integrating a polycarbonate compact freeform lens of small form factor with traditional LED packaging. Optical performance of the ASLP was investigated by both numerical simulation based on Monte Carlo ray tracing method and experiments. Results demonstrated that, comparing with traditional LED module integrated with secondary optics, the ASLP had advantages of much smaller size in volume (approximately 1/8), higher system lumen efficiency (approximately 8.1%), lower cost and more convenience for customers to design and assembly, enabling possible much wider applications of LED for general road lighting. Tolerance analyses were also conducted. Installation errors of horizontal and vertical deviations had more effects on the shape and uniformity of radiation pattern compared with rotational deviation. The tolerances of horizontal, vertical and rotational deviations of this lens were 0.11 mm, 0.14 mm and 2.4 degrees respectively, which were acceptable in engineering.

  3. Photoperiod shift effects on yield characteristics of rice

    NASA Technical Reports Server (NTRS)

    Volk, G. M.; Mitchell, C. A.

    1995-01-01

    Edible yield must be maximized for each crop species selected for inclusion in the Controlled Ecological Life-Support System (CELSS) proposed by NASA to support long-term manned space missions. In a greenhouse study aimed at increasing biomass partitioning to rice (Oryza sativa L.) grain, plants of the high yielding semi-dwarf rice cultivar Ai-Nan-Tsao were started in pots under 8-h photoperiods at a density of 212 plants m-2. After different periods of time under 8-h photoperiods, pots were switched to continuous light for the remainder of the cropping cycle. Continuous light did not delay time to first panicle emergence (60 d) or time to harvest (83 d). There was a positive correlation between the length of continuous light treatments and nongrain biomass. Grain yield (1.6 +/- 0.2 g plant-1) did not increase in continuous light. Yield-efficiency rate (grain weight per length of cropping cycle, canopy volume, and weight of nongrain shoot biomass) was used to compare treatments. Small Ai-Nan-Tsao rice canopies grown under 8-h photoperiods were more efficient producers of grain than canopies grown under continuous light for a portion of the rice cropping cycle.

  4. Volume-scalable high-brightness three-dimensional visible light source

    DOEpatents

    Subramania, Ganapathi; Fischer, Arthur J; Wang, George T; Li, Qiming

    2014-02-18

    A volume-scalable, high-brightness, electrically driven visible light source comprises a three-dimensional photonic crystal (3DPC) comprising one or more direct bandgap semiconductors. The improved light emission performance of the invention is achieved based on the enhancement of radiative emission of light emitters placed inside a 3DPC due to the strong modification of the photonic density-of-states engendered by the 3DPC.

  5. Laser Light Scattering Diagnostic for Measurement of Flow Velocity in Vicinity of Propagating Shock Waves

    NASA Technical Reports Server (NTRS)

    Seasholtz, Richard G.; Buggele, Alvin E.

    2002-01-01

    A laser light scattering diagnostic for measurement of dynamic flow velocity at a point is described. The instrument is being developed for use in the study of propagating shock waves and detonation waves in pulse detonation engines under development at the NASA Glenn Research Center (GRC). The approach uses a Fabry-Perot interferometer to measure the Doppler shift of laser light scattered from small (submicron) particles in the flow. The high-speed detection system required to resolve the transient response as a shock wave crosses the probe volume uses fast response photodetectors, and a PC based data acquisition system. Preliminary results of measurements made in the GRC Mach 4, 10 by 25 cm supersonic wind tunnel are presented. Spontaneous condensation of water vapor in the flow is used as seed. The tunnel is supplied with continuous air flow at up to 45 psia and the flow is exhausted into the GRC laboratory-wide altitude exhaust system at pressures down to 0.3 psia.

  6. In vivo light scattering for the detection of cancerous and precancerous lesions of the cervix

    PubMed Central

    Mourant, Judith R.; Powers, Tamara M.; Bocklage, Thérese J.; Greene, Heather M.; Dorin, Maxine H.; Waxman, Alan G.; Zsemlye, Meggan M.; Smith, Harriet O.

    2009-01-01

    A non-invasive optical diagnostic system for detection of cancerous and precancerous lesions of the cervix was evaluated, in vivo. The optical system included a fiber optic probe designed to measure polarized and unpolarized light transport properties of a small volume of tissue. An algorithm for diagnosing tissue based on the optical measurements was developed which used four optical properties, three of which were related to light scattering properties and the fourth of which was related to hemoglobin concentration. A sensitivity of ∼77% and specificities in the mid 60's were obtained for separating high grade squamous intraepithelial lesions and cancer from other pathologies and normal tissue. The use of different cross-validation methods in algorithm development is analyzed and the relative difficulties of diagnosing certain pathologies is assessed. Furthermore, the robustness of the optical system for use by different doctors and to changes in fiber optic probe were also assessed and potential improvements in the optical system are discussed. PMID:19340117

  7. Simultaneous multiview capture and fusion improves spatial resolution in wide-field and light-sheet microscopy

    PubMed Central

    Wu, Yicong; Chandris, Panagiotis; Winter, Peter W.; Kim, Edward Y.; Jaumouillé, Valentin; Kumar, Abhishek; Guo, Min; Leung, Jacqueline M.; Smith, Corey; Rey-Suarez, Ivan; Liu, Huafeng; Waterman, Clare M.; Ramamurthi, Kumaran S.; La Riviere, Patrick J.; Shroff, Hari

    2016-01-01

    Most fluorescence microscopes are inefficient, collecting only a small fraction of the emitted light at any instant. Besides wasting valuable signal, this inefficiency also reduces spatial resolution and causes imaging volumes to exhibit significant resolution anisotropy. We describe microscopic and computational techniques that address these problems by simultaneously capturing and subsequently fusing and deconvolving multiple specimen views. Unlike previous methods that serially capture multiple views, our approach improves spatial resolution without introducing any additional illumination dose or compromising temporal resolution relative to conventional imaging. When applying our methods to single-view wide-field or dual-view light-sheet microscopy, we achieve a twofold improvement in volumetric resolution (~235 nm × 235 nm × 340 nm) as demonstrated on a variety of samples including microtubules in Toxoplasma gondii, SpoVM in sporulating Bacillus subtilis, and multiple protein distributions and organelles in eukaryotic cells. In every case, spatial resolution is improved with no drawback by harnessing previously unused fluorescence. PMID:27761486

  8. Detecting an Extended Light Source through a Lens

    ERIC Educational Resources Information Center

    Litaker, E. T.; Machacek, J. R.; Gay, T. J.

    2011-01-01

    We present a Monte Carlo simulation of a cylindrical luminescent volume and a typical lens-detector system. The results of this simulation yield a graphically simple picture of the regions within the cylindrical volume from which this system detects light. Because the cylindrical volume permits large angles of incidence, we use a modification of…

  9. Quantitative photoplethysmography: Lambert-Beer law or inverse function incorporating light scatter.

    PubMed

    Cejnar, M; Kobler, H; Hunyor, S N

    1993-03-01

    Finger blood volume is commonly determined from measurement of infra-red (IR) light transmittance using the Lambert-Beer law of light absorption derived for use in non-scattering media, even when such transmission involves light scatter around the phalangeal bone. Simultaneous IR transmittance and finger volume were measured over the full dynamic range of vascular volumes in seven subjects and outcomes compared with data fitted according to the Lambert-Beer exponential function and an inverse function derived for light attenuation by scattering materials. Curves were fitted by the least-squares method and goodness of fit was compared using standard errors of estimate (SEE). The inverse function gave a better data fit in six of the subjects: mean SEE 1.9 (SD 0.7, range 0.7-2.8) and 4.6 (2.2, 2.0-8.0) respectively (p < 0.02, paired t-test). Thus, when relating IR transmittance to blood volume, as occurs in the finger during measurements of arterial compliance, an inverse function derived from a model of light attenuation by scattering media gives more accurate results than the traditional exponential fit.

  10. The effect of the processing and formulation parameters on the size of nanoparticles based on block copolymers of poly(ethylene glycol) and poly(N-isopropylacrylamide) with and without hydrolytically sensitive groups.

    PubMed

    Neradovic, D; Soga, O; Van Nostrum, C F; Hennink, W E

    2004-05-01

    Block copolymers of poly(ethylene glycol) (PEG) as a hydrophilic block and N-isopropylacrylamide (PNIPAAm) or poly (NIPAAm-co-N-(2-hydroxypropyl) methacrylamide-dilactate) (poly(NIPAAm-co-HPMAm-dilactate)) as a thermosensitive block, are able to self-assemble in water into nanoparticles above the cloud point (CP) of the thermosensitive block. The influence of processing and the formulation parameters on the size of the nanoparticles was studied using dynamic light scattering. PNIPAAm-b-PEG 2000 polymers were not suitable for the formation of small and stable particles. Block copolymers with PEG 5000 and 10000 formed relatively small and stable particles in aqueous solutions at temperatures above the CP of the thermosensitive block. Their size decreased with increasing molecular weight of the thermosensitive block, decreasing polymer concentration and using water instead of phosphate buffered saline as solvent. Extrusion and ultrasonication were inefficient methods to size down the polymeric nanoparticles. The heating rate of the polymer solutions was a dominant factor for the size of the nanoparticles. When an aqueous polymer solution was slowly heated through the CP, rather large particles (> or = 200 nm) were formed. Regardless the polymer composition, small nanoparticles (50-70 nm) with a narrow size distribution were formed, when a small volume of an aqueous polymer solution below the CP was added to a large volume of heated water. In this way the thermosensitive block copolymers rapidly pass their CP ('heat shock' procedure), resulting in small and stable nanoparticles.

  11. Research@ARL. Volume 4, Issue 1, November 2015

    DTIC Science & Technology

    2015-11-01

    Durham, NC • Orlando, FL Visit ARL’s web site at www.arl.army.mil 3 FOREWORD Dr. Thomas P. Russell Director, U.S. Army Research Laboratory Thank you...either to sense or to communicate. This volume presents papers in all of these areas: the generation of light energy; the detection of light energy...present papers in all of these areas: the generation of light energy, the detection of light energy, the use of light to measure and sense, and the

  12. Continuity of states between the cholesteric → line hexatic transition and the condensation transition in DNA solutions

    DOE PAGES

    Yasar, Selcuk; Podgornik, Rudolf; Valle-Orero, Jessica; ...

    2014-11-05

    A new method of finely temperature-tuning osmotic pressure allows one to identify the cholesteric → line hexatic transition of oriented or unoriented long-fragment DNA bundles in monovalent salt solutions as first order, with a small but finite volume discontinuity. This transition is similar to the osmotic pressure-induced expanded → condensed DNA transition in polyvalent salt solutions at small enough polyvalent salt concentrations. Therefore there exists a continuity of states between the two. This finding with the corresponding empirical equation of state, effectively relates the phase diagram of DNA solutions for monovalent salts to that for polyvalent salts and sheds somemore » light on the complicated interactions between DNA molecules at high densities.« less

  13. Rapid Evaluation of Platelet Function With T2 Magnetic Resonance

    PubMed Central

    Cuker, Adam; Husseinzadeh, Holleh; Lebedeva, Tatiana; Marturano, Joseph E.; Massefski, Walter; Lowery, Thomas J.; Lambert, Michele P.; Abrams, Charles S.; Weisel, John W.

    2016-01-01

    Objectives: The clinical diagnosis of qualitative platelet disorders (QPDs) based on light transmission aggregometry (LTA) requires significant blood volume, time, and expertise, all of which can be barriers to utilization in some populations and settings. Our objective was to develop a more rapid assay of platelet function by measuring platelet-mediated clot contraction in small volumes (35 µL) of whole blood using T2 magnetic resonance (T2MR). Methods: We established normal ranges for platelet-mediated clot contraction using T2MR, used these ranges to study patients with known platelet dysfunction, and then evaluated agreement between T2MR and LTA with arachidonic acid, adenosine diphosphate, epinephrine, and thrombin receptor activator peptide. Results: Blood from 21 healthy donors was studied. T2MR showed 100% agreement with LTA with each of the four agonists and their cognate inhibitors tested. T2MR successfully detected abnormalities in each of seven patients with known QPDs, with the exception of one patient with a novel mutation leading to Hermansky-Pudlak syndrome. T2MR appeared to detect platelet function at similar or lower platelet counts than LTA. Conclusions: T2MR may provide a clinically useful approach to diagnose QPDs using small volumes of whole blood, while also providing new insight into platelet biology not evident using plasma-based platelet aggregation tests. PMID:28028118

  14. [Submicroscopic changes in ciliated cells of the epithelium of the oviduct in cows during the estrus cycle].

    PubMed

    Uhrín, V; Kliment, J

    1983-03-01

    The submicroscopic changes in the ciliary cells of the ampullar part of oviduct are of qualitative as well as quantitative nature. The mitochondria are mainly located in the supranuclear region. They are small, having densely arranged lamelliform cristae and dense matrix. They have the largest volume in metoestrus and the highest number and the largest surface already during oestrus. The volume and surface of granular endoplasmic reticulum culminates already during pro-oestrus. The reticulum occurs mainly over the nucleus where it produces tubuli densely covered with ribosomes which begin to dilate already during pro-oestrus. The Golgi apparatus and the membranes of smooth reticulum are poorly developed and their quantitative changes during the cycle are not significant. Various forms of lysosomes, whose volume reaches its maximum in dioestrus and during pro-oestrus, constitute a constant component of cytoplasm. Secretory granules occur only rarely in these cells. Kinocilia grow from the basal corpuscles and are more frequent on cells with a light cytoplasm. Higher-density cells have more micro-villi between kinocilia. Deciliation with the disintegration of membrane, filaments and often also the basal corpuscles is observed during metoestrus and at the beginning of dioestrus. Reciliation begins with the formation of basal corpuscles and their replication at the end of dioestrus and in pro-oestrus. The frequency of ciliary regeneration is comparatively small.

  15. A Measurement of the holographic minimum observable beam branching ratio in the Fermilab 15-foot bubble chamber

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aderholz, M.; Aggarwal, M.M.; Akbari, H.

    1997-01-01

    Holography has been used successfully in combination with conventional optics for the first time in a large cryogenic bubble chamber, the 15-Foot Bubble Chamber at Fermilab, during a physics run. The innovative system combined the reference beam with the object beam, illuminating a conical volume of {approx} 1.4 m{sup 3}. Bubble tracks from neutrino interactions with a width of {approx} 120 {micro}m have been recorded with good contrast. The ratio of intensities of the object light to the reference light striking the film is called the Beam Branching Ratio. We obtained in our experiment an exceedingly small minimum-observable ratio ofmore » (0.54 {+-} 0.21) x 10{sup -7}. The technology has the potential for a wide range of applications.« less

  16. Measurement system to determine the total and angle-resolved light scattering of optical components in the deep-ultraviolet and vacuum-ultraviolet spectral regions

    NASA Astrophysics Data System (ADS)

    Schröder, Sven; Gliech, Stefan; Duparré, Angela

    2005-10-01

    An instrumentation for total and angle-resolved scattering (ARS) at 193 and 157 nm has been developed at the Fraunhofer Institute in Jena to meet the severe requirements for scattering analysis of deep- and vacuum-ultraviolet optical components. Extremely low backscattering levels of 10^-6 for the total scattering measurements and more than 9 orders of magnitude dynamic range for ARS have been accomplished. Examples of application extend from the control of at-wavelength scattering losses of superpolished substrates with rms roughness as small as 0.1 nm to the detection of volume material scattering and the study into the scattering of multilayer coatings. In addition, software programs were developed to model the roughness-induced light scattering of substrates and thin-film coatings.

  17. Lattice Light Sheet Microscopy: Imaging Molecules to Embryos at High Spatiotemporal Resolution

    PubMed Central

    Chen, Bi-Chang; Legant, Wesley R.; Wang, Kai; Shao, Lin; Milkie, Daniel E.; Davidson, Michael W.; Janetopoulos, Chris; Wu, Xufeng S.; Hammer, John A.; Liu, Zhe; English, Brian P.; Mimori-Kiyosue, Yuko; Romero, Daniel P.; Ritter, Alex T.; Lippincott-Schwartz, Jennifer; Fritz-Laylin, Lillian; Mullins, R. Dyche; Mitchell, Diana M.; Bembenek, Joshua N.; Reymann, Anne-Cecile; Böhme, Ralph; Grill, Stephan W.; Wang, Jennifer T.; Seydoux, Geraldine; Tulu, U. Serdar; Kiehart, Daniel P.; Betzig, Eric

    2015-01-01

    Although fluorescence microscopy provides a crucial window into the physiology of living specimens, many biological processes are too fragile, too small, or occur too rapidly to see clearly with existing tools. We crafted ultra-thin light sheets from two-dimensional optical lattices that allowed us to image three-dimensional (3D) dynamics for hundreds of volumes, often at sub-second intervals, at the diffraction limit and beyond. We applied this to systems spanning four orders of magnitude in space and time, including the diffusion of single transcription factor molecules in stem cell spheroids, the dynamic instability of mitotic microtubules, the immunological synapse, neutrophil motility in a 3D matrix, and embryogenesis in Caenorhabditis elegans and Drosophila melanogaster. The results provide a visceral reminder of the beauty and complexity of living systems. PMID:25342811

  18. Fiber-Optic Chemical Sensors and Fiber-Optic Bio-Sensors

    PubMed Central

    Pospíšilová, Marie; Kuncová, Gabriela; Trögl, Josef

    2015-01-01

    This review summarizes principles and current stage of development of fiber-optic chemical sensors (FOCS) and biosensors (FOBS). Fiber optic sensor (FOS) systems use the ability of optical fibers (OF) to guide the light in the spectral range from ultraviolet (UV) (180 nm) up to middle infrared (IR) (10 µm) and modulation of guided light by the parameters of the surrounding environment of the OF core. The introduction of OF in the sensor systems has brought advantages such as measurement in flammable and explosive environments, immunity to electrical noises, miniaturization, geometrical flexibility, measurement of small sample volumes, remote sensing in inaccessible sites or harsh environments and multi-sensing. The review comprises briefly the theory of OF elaborated for sensors, techniques of fabrications and analytical results reached with fiber-optic chemical and biological sensors. PMID:26437407

  19. Serum neurofilament as a predictor of disease worsening and brain and spinal cord atrophy in multiple sclerosis.

    PubMed

    Barro, Christian; Benkert, Pascal; Disanto, Giulio; Tsagkas, Charidimos; Amann, Michael; Naegelin, Yvonne; Leppert, David; Gobbi, Claudio; Granziera, Cristina; Yaldizli, Özgür; Michalak, Zuzanna; Wuerfel, Jens; Kappos, Ludwig; Parmar, Katrin; Kuhle, Jens

    2018-05-30

    Neuro-axonal injury is a key factor in the development of permanent disability in multiple sclerosis. Neurofilament light chain in peripheral blood has recently emerged as a biofluid marker reflecting neuro-axonal damage in this disease. We aimed at comparing serum neurofilament light chain levels in multiple sclerosis and healthy controls, to determine their association with measures of disease activity and their ability to predict future clinical worsening as well as brain and spinal cord volume loss. Neurofilament light chain was measured by single molecule array assay in 2183 serum samples collected as part of an ongoing cohort study from 259 patients with multiple sclerosis (189 relapsing and 70 progressive) and 259 healthy control subjects. Clinical assessment, serum sampling and MRI were done annually; median follow-up time was 6.5 years. Brain volumes were quantified by structural image evaluation using normalization of atrophy, and structural image evaluation using normalization of atrophy, cross-sectional, cervical spinal cord volumes using spinal cord image analyser (cordial). Results were analysed using ordinary linear regression models and generalized estimating equation modelling. Serum neurofilament light chain was higher in patients with a clinically isolated syndrome or relapsing remitting multiple sclerosis as well as in patients with secondary or primary progressive multiple sclerosis than in healthy controls (age adjusted P < 0.001 for both). Serum neurofilament light chain above the 90th percentile of healthy controls values was an independent predictor of Expanded Disability Status Scale worsening in the subsequent year (P < 0.001). The probability of Expanded Disability Status Scale worsening gradually increased by higher serum neurofilament light chain percentile category. Contrast enhancing and new/enlarging lesions were independently associated with increased serum neurofilament light chain (17.8% and 4.9% increase per lesion respectively; P < 0.001). The higher the serum neurofilament light chain percentile level, the more pronounced was future brain and cervical spinal volume loss: serum neurofilament light chain above the 97.5th percentile was associated with an additional average loss in brain volume of 1.5% (P < 0.001) and spinal cord volume of 2.5% over 5 years (P = 0.009). Serum neurofilament light chain correlated with concurrent and future clinical and MRI measures of disease activity and severity. High serum neurofilament light chain levels were associated with both brain and spinal cord volume loss. Neurofilament light chain levels are a real-time, easy to measure marker of neuro-axonal injury that is conceptually more comprehensive than brain MRI.

  20. Solar cells based on particulate structure of active layer: Investigation of light absorption by an ordered system of spherical submicron silicon particles

    NASA Astrophysics Data System (ADS)

    Miskevich, Alexander A.; Loiko, Valery A.

    2015-12-01

    Enhancement of the performance of photovoltaic cells through increasing light absorption due to optimization of an active layer is considered. The optimization consists in creation of particulate structure of active layer. The ordered monolayers and multilayers of submicron crystalline silicon (c-Si) spherical particles are examined. The quasicrystalline approximation (QCA) and the transfer matrix method (TMM) are used to calculate light absorption in the wavelength range from 0.28 μm to 1.12 μm. The integrated over the terrestial solar spectral irradiance "Global tilt" ASTM G173-03 absorption coefficient is calculated. In the wavelength range of small absorption index of c-Si (0.8-1.12 μm) the integral absorption coefficient of monolayer can be more than 20 times higher than the one of the plane-parallel plate of the equivalent volume of material. In the overall considered range (0.28-1.12 μm) the enhancement factor up to ~1.45 for individual monolayer is observed. Maximum value of the spectral absorption coefficient approaches unity for multilayers consisting of large amount of sparse monolayers of small particles. Multilayers with variable concentration and size of particles in the monolayer sequences are considered. Absorption increasing by such gradient multilayers as compared to the non-gradient ones is illustrated. The considered structures are promising for creation of high efficiency thin-film solar cells.

  1. Childhood-Onset Asthma in Smokers. Association between CT Measures of Airway Size, Lung Function, and Chronic Airflow Obstruction

    PubMed Central

    Hardin, Megan E.; Come, Carolyn E.; San José Estépar, Raúl; Ross, James C.; Kurugol, Sila; Okajima, Yuka; Han, MeiLan K.; Kim, Victor; Ramsdell, Joe; Silverman, Edwin K.; Crapo, James D.; Lynch, David A.; Make, Barry; Barr, R. Graham; Hersh, Craig P.; Washko, George R.

    2014-01-01

    Rationale and Objectives: Asthma is associated with chronic airflow obstruction. Our goal was to assess the association of computed tomographic measures of airway wall volume and lumen volume with the FEV1 and chronic airflow obstruction in smokers with childhood-onset asthma. Methods: We analyzed clinical, lung function, and volumetric computed tomographic airway volume data from 7,266 smokers, including 590 with childhood-onset asthma. Small wall volume and small lumen volume of segmental airways were defined as measures 1 SD below the mean. We assessed the association between small wall volume, small lumen volume, FEV1, and chronic airflow obstruction (post-bronchodilator FEV1/FVC ratio < 0.7) using linear and logistic models. Measurements and Main Results: Compared with subjects without childhood-onset asthma, those with childhood-onset asthma had smaller wall volume and lumen volume (P < 0.0001) of segmental airways. Among subjects with childhood-onset asthma, those with the smallest wall volume and lumen volume had the lowest FEV1 and greatest odds of chronic airflow obstruction. A similar tendency was seen in those without childhood-onset asthma. When comparing these two groups, both small wall volume and small lumen volume were more strongly associated with FEV1 and chronic airflow obstruction among subjects with childhood-asthma in multivariate models. Conclusion: In smokers with childhood-onset asthma, smaller airways are associated with reduced lung function and chronic airflow obstruction. Clinical trial registered with www.clinicaltrials.gov (NCT00608764). PMID:25296268

  2. Childhood-onset asthma in smokers. association between CT measures of airway size, lung function, and chronic airflow obstruction.

    PubMed

    Diaz, Alejandro A; Hardin, Megan E; Come, Carolyn E; San José Estépar, Raúl; Ross, James C; Kurugol, Sila; Okajima, Yuka; Han, MeiLan K; Kim, Victor; Ramsdell, Joe; Silverman, Edwin K; Crapo, James D; Lynch, David A; Make, Barry; Barr, R Graham; Hersh, Craig P; Washko, George R

    2014-11-01

    Asthma is associated with chronic airflow obstruction. Our goal was to assess the association of computed tomographic measures of airway wall volume and lumen volume with the FEV1 and chronic airflow obstruction in smokers with childhood-onset asthma. We analyzed clinical, lung function, and volumetric computed tomographic airway volume data from 7,266 smokers, including 590 with childhood-onset asthma. Small wall volume and small lumen volume of segmental airways were defined as measures 1 SD below the mean. We assessed the association between small wall volume, small lumen volume, FEV1, and chronic airflow obstruction (post-bronchodilator FEV1/FVC ratio < 0.7) using linear and logistic models. Compared with subjects without childhood-onset asthma, those with childhood-onset asthma had smaller wall volume and lumen volume (P < 0.0001) of segmental airways. Among subjects with childhood-onset asthma, those with the smallest wall volume and lumen volume had the lowest FEV1 and greatest odds of chronic airflow obstruction. A similar tendency was seen in those without childhood-onset asthma. When comparing these two groups, both small wall volume and small lumen volume were more strongly associated with FEV1 and chronic airflow obstruction among subjects with childhood-asthma in multivariate models. In smokers with childhood-onset asthma, smaller airways are associated with reduced lung function and chronic airflow obstruction. Clinical trial registered with www.clinicaltrials.gov (NCT00608764).

  3. Photomorphogenesis, photosynthesis, and seed yield of wheat plants grown under red light-emitting diodes (LEDs) with and without supplemental blue lighting

    NASA Technical Reports Server (NTRS)

    Goins, G. D.; Yorio, N. C.; Sanwo, M. M.; Brown, C. S.; Sager, J. C. (Principal Investigator)

    1997-01-01

    Red light-emitting diodes (LEDs) are a potential light source for growing plants in spaceflight systems because of their safety, small mass and volume, wavelength specificity, and longevity. Despite these attractive features, red LEDs must satisfy requirements for plant photosynthesis and photomorphogenesis for successful growth and seed yield. To determine the influence of gallium aluminium arsenide (GaAlAs) red LEDs on wheat photomorphogenesis, photosynthesis, and seed yield, wheat (Triticum aestivum L., cv. 'USU-Super Dwarf') plants were grown under red LEDs and compared to plants grown under daylight fluorescent (white) lamps and red LEDs supplemented with either 1% or 10% blue light from blue fluorescent (BF) lamps. Compared to white light-grown plants, wheat grown under red LEDs alone demonstrated less main culm development during vegetative growth through preanthesis, while showing a longer flag leaf at 40 DAP and greater main culm length at final harvest (70 DAP). As supplemental BF light was increased with red LEDs, shoot dry matter and net leaf photosynthesis rate increased. At final harvest, wheat grown under red LEDs alone displayed fewer subtillers and a lower seed yield compared to plants grown under white light. Wheat grown under red LEDs+10% BF light had comparable shoot dry matter accumulation and seed yield relative to wheat grown under white light. These results indicate that wheat can complete its life cycle under red LEDs alone, but larger plants and greater amounts of seed are produced in the presence of red LEDs supplemented with a quantity of blue light.

  4. Dielectric relaxation behavior of colloidal suspensions of palladium nanoparticle chains dispersed in PVP/EG solution.

    PubMed

    Chen, Zhen; Zhao, Kong-Shuang; Guo, Lin; Feng, Cai-Hong

    2007-04-28

    Dielectric measurements were carried out on colloidal suspensions of palladium nanoparticle chains dispersed in poly(vinyl pyrrolidone)/ethylene glycol (PVP/EG) solution with different particle volume fractions, and dielectric relaxation with relaxation time distribution and small relaxation amplitude was observed in the frequency range from 10(5) to 10(7) Hz. By means of the method based on logarithmic derivative of the dielectric constant and a numerical Kramers-Kronig transform method, two dielectric relaxations were confirmed and dielectric parameters were determined from the dielectric spectra. The dielectric parameters showed a strong dependence on the volume fraction of palladium nanoparticle chain. Through analyzing limiting conductivity at low frequency, the authors found the conductance percolation phenomenon of the suspensions, and the threshold volume fraction is about 0.18. It was concluded from analyzing the dielectric parameters that the high frequency dielectric relaxation results from interfacial polarization and the low frequency dielectric relaxation is a consequence of counterion polarization. They also found that the dispersion state of the palladium nanoparticle chain in PVP/EG solution is dependent on the particle volume fraction, and this may shed some light on a better application of this kind of materials.

  5. Can a droplet break up under flow without elongating? Fragmentation of smectic monodisperse droplets

    NASA Astrophysics Data System (ADS)

    Courbin, L.; Engl, W.; Panizza, P.

    2004-06-01

    We study the fragmentation under shear flow of smectic monodisperse droplets at high volume fraction. Using small angle light scattering and optical microscopy, we reveal the existence of a break-up mechanism for which the droplets burst into daughter droplets of the same size. Surprisingly, this fragmentation process, which is strain controlled and occurs homogeneously in the cell, does not require any transient elongation of the droplets. Systematic experiments as a function of the initial droplet size and the applied shear rate show that the rupture is triggered by an instability of the inner droplet structure.

  6. Positional calibration of an ultrasound image-guided robotic breast biopsy system.

    PubMed

    Nelson, Thomas R; Tran, Amy; Fakourfar, Hourieh; Nebeker, Jakob

    2012-03-01

    Precision biopsy of small lesions is essential in providing high-quality patient diagnosis and management. Localization depends on high-quality imaging. We have developed a dedicated, fully automatic volume breast ultrasound (US) imaging system for early breast cancer detection. This work focuses on development of an image-guided robotic biopsy system that is integrated with the volume breast US system for performing minimally invasive breast biopsies. The objective of this work was to assess the positional accuracy of the robotic system for breast biopsy. We have adapted a compact robotic arm for performing breast biopsy. The arm incorporates a force torque sensor and is modified to accommodate breast biopsy sampling needles mounted on the robot end effector. Volume breast US images are used as input to a targeting algorithm that provides the physician with control of biopsy device guidance and trajectory optimization. In this work, the positional accuracy was evaluated using (1) a light-emitting diode (LED) mounted on the end effector and (2) a LED mounted on the end of a biopsy needle, each of which was imaged for each robot controller position as part of mapping the positional accuracy throughout a volume that would contain the breast. We measured the error in each location and the cumulative error. Robotic device performance over the volume provided mean accuracy ± SD of 0.76 ± 0.13 mm (end effector) and 0.55 ± 0.13 mm (needle sample location), sufficient for a targeting accuracy within ±1 mm, which is suitable for clinical use. Depth positioning error also was small: 0.38 ± 0.03 mm. Reproducibility was excellent with less than 0.5% variation. Overall accuracy and reproducibility of the compact robotic device were excellent, well within clinical biopsy performance requirements. Volume breast US data provide high-quality input to a biopsy sampling algorithm under physician control. Robotic devices may provide more precise device placement, assisting physicians with biopsy procedures.

  7. Dual multispectral and 3D structured light laparoscope

    NASA Astrophysics Data System (ADS)

    Clancy, Neil T.; Lin, Jianyu; Arya, Shobhit; Hanna, George B.; Elson, Daniel S.

    2015-03-01

    Intraoperative feedback on tissue function, such as blood volume and oxygenation would be useful to the surgeon in cases where current clinical practice relies on subjective measures, such as identification of ischaemic bowel or tissue viability during anastomosis formation. Also, tissue surface profiling may be used to detect and identify certain pathologies, as well as diagnosing aspects of tissue health such as gut motility. In this paper a dual modality laparoscopic system is presented that combines multispectral reflectance and 3D surface imaging. White light illumination from a xenon source is detected by a laparoscope-mounted fast filter wheel camera to assemble a multispectral image (MSI) cube. Surface shape is then calculated using a spectrally-encoded structured light (SL) pattern detected by the same camera and triangulated using an active stereo technique. Images of porcine small bowel were acquired during open surgery. Tissue reflectance spectra were acquired and blood volume was calculated at each spatial pixel across the bowel wall and mesentery. SL features were segmented and identified using a `normalised cut' algoritm and the colour vector of each spot. Using the 3D geometry defined by the camera coordinate system the multispectral data could be overlaid onto the surface mesh. Dual MSI and SL imaging has the potential to provide augmented views to the surgeon supplying diagnostic information related to blood supply health and organ function. Future work on this system will include filter optimisation to reduce noise in tissue optical property measurement, and minimise spot identification errors in the SL pattern.

  8. Influences of diurnal bright or dim light exposure on urine volume in humans.

    PubMed

    Hyun, Ki-Ja; Nishimura, Shinya; Tokura, Hiromi

    2006-03-01

    We investigated with eight healthy females if 8 hr diurnal (0700 to 1500 h) bright rather than dim light (5,000 vs. 80 lx) influenced urine volume. Environmental illuminance was made identical at all other times besides 07:00 to 15:00 h. The participants spent time at strictly regulated schedules in a bioclimatic chamber (26 degrees C, relative humidity 60%) for 57 h. Blood was drawn (2 ml) just before lunch in order to calculate Creatinine clearance (Ccr). Urine volume was significantly higher during wakefulness and the 8-h sleep period with bright rather than dim light. Ccr was significantly higher after bright light. The results were discussed in terms of suppression of the sympathetic nerve system under the influence of diurnal bright light exposure. We also discussed these in terms of physiological polymorphisms.

  9. Stochastic parameterization for light absorption by internally mixed BC/dust in snow grains for application to climate models

    NASA Astrophysics Data System (ADS)

    Liou, K. N.; Takano, Y.; He, C.; Yang, P.; Leung, L. R.; Gu, Y.; Lee, W. L.

    2014-06-01

    A stochastic approach has been developed to model the positions of BC (black carbon)/dust internally mixed with two snow grain types: hexagonal plate/column (convex) and Koch snowflake (concave). Subsequently, light absorption and scattering analysis can be followed by means of an improved geometric-optics approach coupled with Monte Carlo photon tracing to determine BC/dust single-scattering properties. For a given shape (plate, Koch snowflake, spheroid, or sphere), the action of internal mixing absorbs substantially more light than external mixing. The snow grain shape effect on absorption is relatively small, but its effect on asymmetry factor is substantial. Due to a greater probability of intercepting photons, multiple inclusions of BC/dust exhibit a larger absorption than an equal-volume single inclusion. The spectral absorption (0.2-5 µm) for snow grains internally mixed with BC/dust is confined to wavelengths shorter than about 1.4 µm, beyond which ice absorption predominates. Based on the single-scattering properties determined from stochastic and light absorption parameterizations and using the adding/doubling method for spectral radiative transfer, we find that internal mixing reduces snow albedo substantially more than external mixing and that the snow grain shape plays a critical role in snow albedo calculations through its forward scattering strength. Also, multiple inclusion of BC/dust significantly reduces snow albedo as compared to an equal-volume single sphere. For application to land/snow models, we propose a two-layer spectral snow parameterization involving contaminated fresh snow on top of old snow for investigating and understanding the climatic impact of multiple BC/dust internal mixing associated with snow grain metamorphism, particularly over mountain/snow topography.

  10. Stochastic Parameterization for Light Absorption by Internally Mixed BC/dust in Snow Grains for Application to Climate Models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liou, K. N.; Takano, Y.; He, Cenlin

    2014-06-27

    A stochastic approach to model the positions of BC/dust internally mixed with two snow-grain types has been developed, including hexagonal plate/column (convex) and Koch snowflake (concave). Subsequently, light absorption and scattering analysis can be followed by means of an improved geometric-optics approach coupled with Monte Carlo photon tracing to determine their single-scattering properties. For a given shape (plate, Koch snowflake, spheroid, or sphere), internal mixing absorbs more light than external mixing. The snow-grain shape effect on absorption is relatively small, but its effect on the asymmetry factor is substantial. Due to a greater probability of intercepting photons, multiple inclusions ofmore » BC/dust exhibit a larger absorption than an equal-volume single inclusion. The spectral absorption (0.2 – 5 um) for snow grains internally mixed with BC/dust is confined to wavelengths shorter than about 1.4 um, beyond which ice absorption predominates. Based on the single-scattering properties determined from stochastic and light absorption parameterizations and using the adding/doubling method for spectral radiative transfer, we find that internal mixing reduces snow albedo more than external mixing and that the snow-grain shape plays a critical role in snow albedo calculations through the asymmetry factor. Also, snow albedo reduces more in the case of multiple inclusion of BC/dust compared to that of an equal-volume single sphere. For application to land/snow models, we propose a two-layer spectral snow parameterization containing contaminated fresh snow on top of old snow for investigating and understanding the climatic impact of multiple BC/dust internal mixing associated with snow grain metamorphism, particularly over mountains/snow topography.« less

  11. Using infinite-volume, continuum QED and lattice QCD for the hadronic light-by-light contribution to the muon anomalous magnetic moment

    NASA Astrophysics Data System (ADS)

    Blum, Thomas; Christ, Norman; Hayakawa, Masashi; Izubuchi, Taku; Jin, Luchang; Jung, Chulwoo; Lehner, Christoph

    2017-08-01

    In our previous work, Blum et al. [Phys. Rev. Lett. 118, 022005 (2017), 10.1103/PhysRevLett.118.022005], the connected and leading disconnected hadronic light-by-light contributions to the muon anomalous magnetic moment (g -2 ) have been computed using lattice QCD ensembles corresponding to physical pion mass generated by the RBC/UKQCD Collaboration. However, the calculation is expected to suffer from a significant finite-volume error that scales like 1 /L2 where L is the spatial size of the lattice. In this paper, we demonstrate that this problem is cured by treating the muon and photons in infinite-volume, continuum QED, resulting in a weighting function that is precomputed and saved with affordable cost and sufficient accuracy. We present numerical results for the case when the quark loop is replaced by a muon loop, finding the expected exponential approach to the infinite volume limit and consistency with the known analytic result. We have implemented an improved weighting function which reduces both discretization and finite-volume effects arising from the hadronic part of the amplitude.

  12. Using infinite-volume, continuum QED and lattice QCD for the hadronic light-by-light contribution to the muon anomalous magnetic moment

    DOE PAGES

    Blum, Thomas; Christ, Norman; Hayakawa, Masashi; ...

    2017-08-22

    In our previous work, the connected and leading disconnected hadronic light-by-light contributions to the muon anomalous magnetic moment (g — 2) have been computed using lattice QCD ensembles corresponding to physical pion mass generated by the RBC/UKQCD Collaboration. However, the calculation is expected to suffer from a significant finite-volume error that scales like 1/L 2 where L is the spatial size of the lattice. In this paper, we demonstrate that this problem is cured by treating the muon and photons in infinite-volume, continuum QED, resulting in a weighting function that is precomputed and saved with affordable cost and sufficient accuracy.more » We present numerical results for the case when the quark loop is replaced by a muon loop, finding the expected exponential approach to the infinite volume limit and consistency with the known analytic result. Here, we have implemented an improved weighting function which reduces both discretization and finite-volume effects arising from the hadronic part of the amplitude.« less

  13. Using infinite-volume, continuum QED and lattice QCD for the hadronic light-by-light contribution to the muon anomalous magnetic moment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blum, Thomas; Christ, Norman; Hayakawa, Masashi

    In our previous work, the connected and leading disconnected hadronic light-by-light contributions to the muon anomalous magnetic moment (g — 2) have been computed using lattice QCD ensembles corresponding to physical pion mass generated by the RBC/UKQCD Collaboration. However, the calculation is expected to suffer from a significant finite-volume error that scales like 1/L 2 where L is the spatial size of the lattice. In this paper, we demonstrate that this problem is cured by treating the muon and photons in infinite-volume, continuum QED, resulting in a weighting function that is precomputed and saved with affordable cost and sufficient accuracy.more » We present numerical results for the case when the quark loop is replaced by a muon loop, finding the expected exponential approach to the infinite volume limit and consistency with the known analytic result. Here, we have implemented an improved weighting function which reduces both discretization and finite-volume effects arising from the hadronic part of the amplitude.« less

  14. 40 CFR 1051.635 - What provisions apply to new manufacturers that are small businesses?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Act. For example, we may place sales limits on companies that we designate to be small-volume....201) that manufactures recreational vehicles, but does not otherwise qualify for the small-volume manufacturer provisions of this part, you may ask us to designate you to be a small-volume manufacturer. You...

  15. 40 CFR 80.1622 - Approval for small refiner and small volume refinery status.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... appropriate data to correct the record when the company submits its application. (ii) Foreign small refiners... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Approval for small refiner and small... Approval for small refiner and small volume refinery status. (a) Applications for small refiner or small...

  16. Efficient visibility encoding for dynamic illumination in direct volume rendering.

    PubMed

    Kronander, Joel; Jönsson, Daniel; Löw, Joakim; Ljung, Patric; Ynnerman, Anders; Unger, Jonas

    2012-03-01

    We present an algorithm that enables real-time dynamic shading in direct volume rendering using general lighting, including directional lights, point lights, and environment maps. Real-time performance is achieved by encoding local and global volumetric visibility using spherical harmonic (SH) basis functions stored in an efficient multiresolution grid over the extent of the volume. Our method enables high-frequency shadows in the spatial domain, but is limited to a low-frequency approximation of visibility and illumination in the angular domain. In a first pass, level of detail (LOD) selection in the grid is based on the current transfer function setting. This enables rapid online computation and SH projection of the local spherical distribution of visibility information. Using a piecewise integration of the SH coefficients over the local regions, the global visibility within the volume is then computed. By representing the light sources using their SH projections, the integral over lighting, visibility, and isotropic phase functions can be efficiently computed during rendering. The utility of our method is demonstrated in several examples showing the generality and interactive performance of the approach.

  17. A New View of the Origin of the Solar Wind

    NASA Technical Reports Server (NTRS)

    Woo, Richard; Habbal, Shadia Rifai

    1999-01-01

    This paper uses white-light measurements made by the SOHO LASCO coronagraph and HAO Mauna Loa Mk III K-coronameter to illustrate the new view of solar wind structure deduced originally from radio occultation measurements. It is shown that the density profile closest to the Sun at 1.15 Ro, representing the imprint of the Sun, is carried essentially radially into interplanetary space by small-scale raylike structures that permeate the solar corona and which have only been observed by radio occultation measurements. The only exception is the small volume of interplanetary space occupied by the heliospheric plasma sheet that evolves from coronal streamers within a few solar radii of the Sun. The radial preservation of the density profile also implies that a significant fraction of field lines which extend into interplanetary space originate from the quiet Sun, and are indistinguishable in character from those emanating from polar coronal holes. The white-light measurements dispel the long-held belief that the boundaries of polar coronal holes diverge significantly, and further support the view originally proposed that the fast solar wind originates from the quiet Sun as well as polar coronal holes.

  18. Efficient green lasers for high-resolution scanning micro-projector displays

    NASA Astrophysics Data System (ADS)

    Bhatia, Vikram; Bauco, Anthony S.; Oubei, Hassan M.; Loeber, David A. S.

    2010-02-01

    Laser-based projectors are gaining increased acceptance in mobile device market due to their low power consumption, superior image quality and small size. The basic configuration of such micro-projectors is a miniature mirror that creates an image by raster scanning the collinear red, blue and green laser beams that are individually modulated on a pixel-bypixel basis. The image resolution of these displays can be limited by the modulation bandwidth of the laser sources, and the modulation speed of the green laser has been one of the key limitations in the development of these displays. We will discuss how this limitation is fundamental to the architecture of many laser designs and then present a green laser configuration which overcomes these difficulties. In this green laser architecture infra-red light from a distributed Bragg-reflector (DBR) laser diode undergoes conversion to green light in a waveguided second harmonic generator (SHG) crystal. The direct doubling in a single pass through the SHG crystal allows the device to operate at the large modulation bandwidth of the DBR laser. We demonstrate that the resultant product has a small footprint (<0.7 cc envelope volume), high efficiency (>9% electrical-to-optical conversion) and large modulation bandwidth (>100 MHz).

  19. NASA Ames UV-LED Poster Overview

    NASA Technical Reports Server (NTRS)

    Jaroux, Belgacem Amar

    2015-01-01

    UV-LED is a small satellite technology demonstration payload being flown on the Saudisat-4 spacecraft that is demonstrating non-contacting charge control of an isolated or floating mass using new solid-state ultra-violet light emitting diodes (UV-LEDs). Integrated to the rest of the spacecraft and launched on a Dnepr in June 19, 2014, the project is a collaboration between the NASA Ames Research Center (ARC), Stanford University, and King Abdulaziz City for Science and Technology (KACST). Beginning with its commissioning in December, 2015, the data collected by UV-LED have validated a novel method of charge control that will improve the performance of drag-free spacecraft allowing for concurrent science collection during charge management operations as well as reduce the mass, power and volume required while increasing lifetime and reliability of a charge management subsystem. UV-LED continues to operate, exploring new concepts in non-contacting charge control and collecting data crucial to understanding the lifetime of ultra-violet light emitting diodes in space. These improvements are crucial to the success of ground breaking missions such as LISA and BBO, and demonstrates the ability of low cost small satellite missions to provide technological advances that far exceed mission costs.

  20. Novel drift structures for silicon and compound semiconductor X-ray and gamma-ray detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patt, B.E.; Iwanczyk, J.S.

    Recently developed silicon- and compound-semiconductor-based drift detector structures have produced excellent performance for charged particles, X-rays, and gamma rays and for low-signal visible light detection. The silicon drift detector (SDD) structures that the authors discuss relate to direct X-ray detectors and scintillation photon detectors coupled with scintillators for gamma rays. Recent designs include several novel features that ensure very low dark current and hence low noise. In addition, application of thin window technology ensures a very high quantum efficiency entrance window on the drift photodetector. The main features of the silicon drift structures for X rays and light detection aremore » very small anode capacitance independent of the overall detector size, low noise, and high throughput. To take advantage of the small detector capacitance, the first stage of the electronics needs to be integrated into the detector anode. In the gamma-ray application, factors other than electronic noise dominate, and there is no need to integrate the electronics into the anode. Thus, a different drift structure is needed in conjunction with a high-Z material. The main features in this case are large active detector volume and electron-only induced signal.« less

  1. A path to practical Solar Pumped Lasers via Radiative Energy Transfer

    DOE PAGES

    Reusswig, Philip D.; Nechayev, Sergey; Scherer, Jennifer M.; ...

    2015-10-05

    The optical conversion of incoherent solar radiation into a bright, coherent laser beam enables the application of nonlinear optics to solar energy conversion and storage. Here, we present an architecture for solar pumped lasers that uses a luminescent solar concentrator to decouple the conventional trade-off between solar absorption efficiency and the mode volume of the optical gain material. We report a 750-μm-thick Nd 3+ -doped YAG planar waveguide sensitized by a luminescent CdSe/CdZnS (core/shell) colloidal nanocrystal, yielding a peak cascade energy transfer of 14%, a broad spectral response in the visible portion of the solar spectrum, and an equivalent quasi-CWmore » solar lasing threshold of 23 W-cm -2, or approximately 230 suns. The efficient coupling of incoherent, spectrally broad sunlight in small gain volumes should allow the generation of coherent laser light from intensities of less than 100 suns.« less

  2. A path to practical Solar Pumped Lasers via Radiative Energy Transfer

    PubMed Central

    Reusswig, Philip D.; Nechayev, Sergey; Scherer, Jennifer M.; Hwang, Gyu Weon; Bawendi, Moungi G.; Baldo, Marc. A.; Rotschild, Carmel

    2015-01-01

    The optical conversion of incoherent solar radiation into a bright, coherent laser beam enables the application of nonlinear optics to solar energy conversion and storage. Here, we present an architecture for solar pumped lasers that uses a luminescent solar concentrator to decouple the conventional trade-off between solar absorption efficiency and the mode volume of the optical gain material. We report a 750-μm-thick Nd3+-doped YAG planar waveguide sensitized by a luminescent CdSe/CdZnS (core/shell) colloidal nanocrystal, yielding a peak cascade energy transfer of 14%, a broad spectral response in the visible portion of the solar spectrum, and an equivalent quasi-CW solar lasing threshold of 23 W-cm−2, or approximately 230 suns. The efficient coupling of incoherent, spectrally broad sunlight in small gain volumes should allow the generation of coherent laser light from intensities of less than 100 suns. PMID:26434400

  3. A path to practical Solar Pumped Lasers via Radiative Energy Transfer.

    PubMed

    Reusswig, Philip D; Nechayev, Sergey; Scherer, Jennifer M; Hwang, Gyu Weon; Bawendi, Moungi G; Baldo, Marc A; Rotschild, Carmel

    2015-10-05

    The optical conversion of incoherent solar radiation into a bright, coherent laser beam enables the application of nonlinear optics to solar energy conversion and storage. Here, we present an architecture for solar pumped lasers that uses a luminescent solar concentrator to decouple the conventional trade-off between solar absorption efficiency and the mode volume of the optical gain material. We report a 750-μm-thick Nd(3+)-doped YAG planar waveguide sensitized by a luminescent CdSe/CdZnS (core/shell) colloidal nanocrystal, yielding a peak cascade energy transfer of 14%, a broad spectral response in the visible portion of the solar spectrum, and an equivalent quasi-CW solar lasing threshold of 23 W-cm(-2), or approximately 230 suns. The efficient coupling of incoherent, spectrally broad sunlight in small gain volumes should allow the generation of coherent laser light from intensities of less than 100 suns.

  4. A Metalens with a Near-Unity Numerical Aperture.

    PubMed

    Paniagua-Domínguez, Ramón; Yu, Ye Feng; Khaidarov, Egor; Choi, Sumin; Leong, Victor; Bakker, Reuben M; Liang, Xinan; Fu, Yuan Hsing; Valuckas, Vytautas; Krivitsky, Leonid A; Kuznetsov, Arseniy I

    2018-03-14

    The numerical aperture (NA) of a lens determines its ability to focus light and its resolving capability. Having a large NA is a very desirable quality for applications requiring small light-matter interaction volumes or large angular collections. Traditionally, a large NA lens based on light refraction requires precision bulk optics that ends up being expensive and is thus also a specialty item. In contrast, metasurfaces allow the lens designer to circumvent those issues producing high-NA lenses in an ultraflat fashion. However, so far, these have been limited to numerical apertures on the same order of magnitude as traditional optical components, with experimentally reported NA values of <0.9. Here we demonstrate, both numerically and experimentally, a new approach that results in a diffraction-limited flat lens with a near-unity numerical aperture (NA > 0.99) and subwavelength thickness (∼λ/3), operating with unpolarized light at 715 nm. To demonstrate its imaging capability, the designed lens is applied in a confocal configuration to map color centers in subdiffractive diamond nanocrystals. This work, based on diffractive elements that can efficiently bend light at angles as large as 82°, represents a step beyond traditional optical elements and existing flat optics, circumventing the efficiency drop associated with the standard, phase mapping approach.

  5. A Metalens with a Near-Unity Numerical Aperture

    NASA Astrophysics Data System (ADS)

    Paniagua-Domínguez, Ramón; Yu, Ye Feng; Khaidarov, Egor; Choi, Sumin; Leong, Victor; Bakker, Reuben M.; Liang, Xinan; Fu, Yuan Hsing; Valuckas, Vytautas; Krivitsky, Leonid A.; Kuznetsov, Arseniy I.

    2018-03-01

    The numerical aperture (NA) of a lens determines its ability to focus light and its resolving capability. Having a large NA is a very desirable quality for applications requiring small light-matter interaction volumes or large angular collections. Traditionally, a large NA lens based on light refraction requires precision bulk optics that ends up being expensive and is thus also a specialty item. In contrast, metasurfaces allow the lens designer to circumvent those issues producing high NA lenses in an ultra-flat fashion. However, so far, these have been limited to numerical apertures on the same order of traditional optical components, with experimentally reported values of NA <0.9. Here we demonstrate, both numerically and experimentally, a new approach that results in a diffraction limited flat lens with a near-unity numerical aperture (NA>0.99) and sub-wavelength thickness (~{\\lambda}/3), operating with unpolarized light at 715 nm. To demonstrate its imaging capability, the designed lens is applied in a confocal configuration to map color centers in sub-diffractive diamond nanocrystals. This work, based on diffractive elements able to efficiently bend light at angles as large as 82{\\deg}, represents a step beyond traditional optical elements and existing flat optics, circumventing the efficiency drop associated to the standard, phase mapping approach.

  6. Three-dimensional concentration of light in deeply sub-wavelength, laterally tapered gap-plasmon nanocavities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tagliabue, Giulia; Thomas J. Watson, Sr. Laboratories of Applied Physics, California Institute of Technology, Pasadena, California 91125; Poulikakos, Dimos

    2016-05-30

    Gap-plasmons (GP) in metal-insulator-metal (MIM) structures have shown exceptional performance in guiding and concentrating light within deep subwavelength layers. Reported designs to date exploit tapered thicknesses of the insulating layer in order to confine and focus the GP mode. Here, we propose a mechanism for the three dimensional concentration of light in planar MIM structures which exploits exclusively the lateral tapering of the front metallic layer while keeping a constant thickness of the insulating layer. We demonstrate that an array of tapered planar GP nanocavities can efficiently concentrate light in all three dimensions. A semi-analytical, one-dimensional model provides understanding ofmore » the underlying physics and approximately predicts the behavior of the structure. Three-dimensional simulations are then used to precisely calculate the optical behavior. Cavities with effective volumes as small as 10{sup −5} λ{sup 3} are achieved in an ultrathin MIM configuration. Our design is inherently capable of efficiently coupling with free-space radiation. In addition, being composed of two electrically continuous layers separated by an ultrathin dielectric spacer, it could find interesting applications in the area of active metamaterials or plasmonic photocatalysis where both electrical access and light concentration are required.« less

  7. Interactive Dynamic Volume Illumination with Refraction and Caustics.

    PubMed

    Magnus, Jens G; Bruckner, Stefan

    2018-01-01

    In recent years, significant progress has been made in developing high-quality interactive methods for realistic volume illumination. However, refraction - despite being an important aspect of light propagation in participating media - has so far only received little attention. In this paper, we present a novel approach for refractive volume illumination including caustics capable of interactive frame rates. By interleaving light and viewing ray propagation, our technique avoids memory-intensive storage of illumination information and does not require any precomputation. It is fully dynamic and all parameters such as light position and transfer function can be modified interactively without a performance penalty.

  8. Design of dual-diameter nanoholes for efficient solar-light harvesting

    PubMed Central

    2014-01-01

    A dual-diameter nanohole (DNH) photovoltaic system is proposed, where a top (bottom) layer with large (small) nanoholes is used to improve the absorption for the short-wavelength (long-wavelength) solar incidence, leading to a broadband light absorption enhancement. Through three-dimensional finite-element simulation, the core device parameters, including the lattice constant, nanohole diameters, and nanohole depths, are engineered in order to realize the best light-matter coupling between nanostructured silicon and solar spectrum. The designed bare DNH system exhibits an outstanding absorption capability with a photocurrent density (under perfect internal quantum process) predicted to be 27.93 mA/cm2, which is 17.39%, 26.17%, and over 100% higher than the best single-nanohole (SNH) system, SNH system with an identical Si volume, and equivalent planar configuration, respectively. Considering the fabrication feasibility, a modified DNH system with an anti-reflection coating and back silver reflector is examined by simulating both optical absorption and carrier transport in a coupled way in frequency and three-dimensional spatial domains, achieving a light-conversion efficiency of 13.72%. PACS 85.60.-q; Optoelectronic device; 84.60.Jt; Photovoltaic conversion PMID:25258605

  9. Light clusters in nuclear matter: Excluded volume versus quantum many-body approaches

    NASA Astrophysics Data System (ADS)

    Hempel, Matthias; Schaffner-Bielich, Jürgen; Typel, Stefan; Röpke, Gerd

    2011-11-01

    The formation of clusters in nuclear matter is investigated, which occurs, e.g., in low-energy heavy-ion collisions or core-collapse supernovae. In astrophysical applications, the excluded volume concept is commonly used for the description of light clusters. Here we compare a phenomenological excluded volume approach to two quantum many-body models, the quantum statistical model and the generalized relativistic mean-field model. All three models contain bound states of nuclei with mass number A≤4. It is explored to which extent the complex medium effects can be mimicked by the simpler excluded volume model, regarding the chemical composition and thermodynamic variables. Furthermore, the role of heavy nuclei and excited states is investigated by use of the excluded volume model. At temperatures of a few MeV the excluded volume model gives a poor description of the medium effects on the light clusters, but there the composition is actually dominated by heavy nuclei. At larger temperatures there is a rather good agreement, whereas some smaller differences and model dependencies remain.

  10. Large Volume, Behaviorally-relevant Illumination for Optogenetics in Non-human Primates.

    PubMed

    Acker, Leah C; Pino, Erica N; Boyden, Edward S; Desimone, Robert

    2017-10-03

    This protocol describes a large-volume illuminator, which was developed for optogenetic manipulations in the non-human primate brain. The illuminator is a modified plastic optical fiber with etched tip, such that the light emitting surface area is > 100x that of a conventional fiber. In addition to describing the construction of the large-volume illuminator, this protocol details the quality-control calibration used to ensure even light distribution. Further, this protocol describes techniques for inserting and removing the large volume illuminator. Both superficial and deep structures may be illuminated. This large volume illuminator does not need to be physically coupled to an electrode, and because the illuminator is made of plastic, not glass, it will simply bend in circumstances when traditional optical fibers would shatter. Because this illuminator delivers light over behaviorally-relevant tissue volumes (≈ 10 mm 3 ) with no greater penetration damage than a conventional optical fiber, it facilitates behavioral studies using optogenetics in non-human primates.

  11. New intravascular flow sensor using fiber optics

    NASA Astrophysics Data System (ADS)

    Stenow, Erik N. D.

    1994-12-01

    A new sensor using fiber optics is suggested for blood flow measurements in small vessels. The sensor principle and a first evaluation on a flow model are presented. The new sensor uses small CO2 gas bubbles as flow markers for optical detection. When the bubbles pass an optical window, light emitted from one fiber is reflected and scattered into another fiber. The sensor has been proven to work in a 3 mm flow model using two 110 micrometers optical fibers and a 100 micrometers steel capillary inserted into a 1 mm guide wire. The evaluation of a sensor archetype shows that the new sensor provides a promising method for intravascular blood flow measurement in small vessels. The linearity for steady state flow is studied in the flow interval 30 - 130 ml/min. comparison with ultrasound Doppler flowmetry was performed for pulsatile flow in the interval 25 - 125 ml/min. with a pulse length between 0.5 and 2 s. The use of intravascular administered CO2 in small volumes is harmless because the gas is rapidly dissolved in whole blood.

  12. Ultraviolet spectroscopic breath analysis using hollow-optical fiber as gas cell

    NASA Astrophysics Data System (ADS)

    Iwata, T.; Katagiri, T.; Matsuura, Y.

    2017-02-01

    For breath analysis on ultraviolet absorption spectroscopy, an analysis system using a hollow optical fiber as gas cell is developed. The hollow optical fiber functions as a long path and extremely small volume gas cell. Firstly, the measurement sensitivity of the system is evaluated by using NO gas as a gas sample. The result shows that NO gas with 50 ppb concentration is measured by using a system with a laser-driven, high intensity light source and a 3-meter long, aluminum-coated hollow optical fiber. Then an absorption spectrum of breath sample is measured in the wavelength region of around 200-300 nm and from the spectrum, it is found that the main absorbing components in breath were H2O, isoprene, and O3 converted from O2 by radiation of ultraviolet light. Then the concentration of isoprene in breath is estimated by using multiple linear regression analysis.

  13. Holographic photolysis of caged neurotransmitters

    PubMed Central

    Lutz, Christoph; Otis, Thomas S.; DeSars, Vincent; Charpak, Serge; DiGregorio, David A.; Emiliani, Valentina

    2009-01-01

    Stimulation of light-sensitive chemical probes has become a powerful tool for the study of dynamic signaling processes in living tissue. Classically, this approach has been constrained by limitations of lens–based and point-scanning illumination systems. Here we describe a novel microscope configuration that incorporates a nematic liquid crystal spatial light modulator (LC-SLM) to generate holographic patterns of illumination. This microscope can produce illumination spots of variable size and number and patterns shaped to precisely match user-defined elements in a specimen. Using holographic illumination to photolyse caged glutamate in brain slices, we demonstrate that shaped excitation on segments of neuronal dendrites and simultaneous, multi-spot excitation of different dendrites enables precise spatial and rapid temporal control of glutamate receptor activation. By allowing the excitation volume shape to be tailored precisely, the holographic microscope provides an extremely flexible method for activation of various photosensitive proteins and small molecules. PMID:19160517

  14. Effect of photodynamic therapy on mouse platelets

    NASA Astrophysics Data System (ADS)

    Zhou, Chuannong; Chi, Shunji; Deng, Jinsheng; Zhang, Hua; Liang, Junlin; Ha, Xian-wen

    1993-06-01

    Normal mice received hematoporphyrin derivative (HpD) i.v. prior to red light irradiation and the platelet-rich plasma was prepared and irradiated by red light. The platelets were processed for EM examination and stereological analysis. It was shown the 16 hrs after irradiation almost all platelets were necrotized; 8 hours after irradiation about one fourth of the platelets were necrotized and the remaining were considerably damaged. Immediately after irradiation a small number of platelets became necrotic and most other platelets were swollen and deformated, showing significantly increased mean area, perimeter and short axis, and mean cell volume and cell surface area. The findings indicate that platelets are highly sensitive to PDT action and can be directly and rapidly damaged by PDT even in the absence of vascular endothelial cells. The early platelet photoactivation may play an important role in the initiation of early vascular damage and microcirculatory alterations induced by PDT in vivo.

  15. Observable Protein Crystal Growth Apparatus

    NASA Technical Reports Server (NTRS)

    2001-01-01

    This diagram shows a cross sectrion of the fluid volume of an individual cell in the Observable Protein Crystal Growth Apparatus (OPCGA) to be operated aboard the International Space Station (ISS). The principal investigator is Dr. Alex McPherson of the University of California, Irvine. Each individual cell comprises two sample chambers with a rotating center section that isolates the two from each other until the start of the experiment and after it is completed. The cells are made from optical-quality quartz glass to allow photography and interferometric observations. Each cell has a small light-emitting diode and lens to back-light the solution. In protein crystal growth experiments, a precipitating agent such as a salt solution is used to absorb and hold water but repel the protein molecules. This increases the concentration of protein until the molecules nucleate to form crystals. This cell is one of 96 that make up the experiment module portion of the OPCGA.

  16. Volumetric 3D Display System with Static Screen

    NASA Technical Reports Server (NTRS)

    Geng, Jason

    2011-01-01

    Current display technology has relied on flat, 2D screens that cannot truly convey the third dimension of visual information: depth. In contrast to conventional visualization that is primarily based on 2D flat screens, the volumetric 3D display possesses a true 3D display volume, and places physically each 3D voxel in displayed 3D images at the true 3D (x,y,z) spatial position. Each voxel, analogous to a pixel in a 2D image, emits light from that position to form a real 3D image in the eyes of the viewers. Such true volumetric 3D display technology provides both physiological (accommodation, convergence, binocular disparity, and motion parallax) and psychological (image size, linear perspective, shading, brightness, etc.) depth cues to human visual systems to help in the perception of 3D objects. In a volumetric 3D display, viewers can watch the displayed 3D images from a completely 360 view without using any special eyewear. The volumetric 3D display techniques may lead to a quantum leap in information display technology and can dramatically change the ways humans interact with computers, which can lead to significant improvements in the efficiency of learning and knowledge management processes. Within a block of glass, a large amount of tiny dots of voxels are created by using a recently available machining technique called laser subsurface engraving (LSE). The LSE is able to produce tiny physical crack points (as small as 0.05 mm in diameter) at any (x,y,z) location within the cube of transparent material. The crack dots, when illuminated by a light source, scatter the light around and form visible voxels within the 3D volume. The locations of these tiny voxels are strategically determined such that each can be illuminated by a light ray from a high-resolution digital mirror device (DMD) light engine. The distribution of these voxels occupies the full display volume within the static 3D glass screen. This design eliminates any moving screen seen in previous approaches, so there is no image jitter, and has an inherent parallel mechanism for 3D voxel addressing. High spatial resolution is possible with a full color display being easy to implement. The system is low-cost and low-maintenance.

  17. Orbiting Rainbows Simulation

    NASA Image and Video Library

    2015-04-22

    This simulated image shows how a cloud of glitter in geostationary orbit would be illuminated and controlled by two laser beams. As the cloud orbits Earth, grains scatter the sun's light at different angles like many tiny prisms, similar to how rainbows are produced from light being dispersed by water droplets. That is why the project concept is called "Orbiting Rainbows." The cloud functions like a reflective surface, allowing the exoplanet (displayed in the bottom right) to be imaged. The orbit path is shown in the top right. On the bottom left, Earth's image is seen behind the cloud. To image an exoplanet, the cloud would need to have a diameter of nearly 98 feet (30 meters). This simulation confines the cloud to a 3.3 x 3.3 x 3.3 foot volume (1 x 1 x 1 meter volume) to simplify the computations. The elements of the orbiting telescope are not to scale. Orbiting Rainbows is currently in Phase II development through the NASA Innovative Advanced Concepts (NIAC) Program. It was one of five technology proposals chosen for continued study in 2014. In the current phase, Orbiting Rainbows researchers are conducting small-scale ground experiments to demonstrate how granular materials can be manipulated using lasers and simulations of how the imaging system would behave in orbit. http://photojournal.jpl.nasa.gov/catalog/PIA19318

  18. Method for accurate quantitation of background tissue optical properties in the presence of emission from a strong fluorescence marker

    NASA Astrophysics Data System (ADS)

    Bravo, Jaime; Davis, Scott C.; Roberts, David W.; Paulsen, Keith D.; Kanick, Stephen C.

    2015-03-01

    Quantification of targeted fluorescence markers during neurosurgery has the potential to improve and standardize surgical distinction between normal and cancerous tissues. However, quantitative analysis of marker fluorescence is complicated by tissue background absorption and scattering properties. Correction algorithms that transform raw fluorescence intensity into quantitative units, independent of absorption and scattering, require a paired measurement of localized white light reflectance to provide estimates of the optical properties. This study focuses on the unique problem of developing a spectral analysis algorithm to extract tissue absorption and scattering properties from white light spectra that contain contributions from both elastically scattered photons and fluorescence emission from a strong fluorophore (i.e. fluorescein). A fiber-optic reflectance device was used to perform measurements in a small set of optical phantoms, constructed with Intralipid (1% lipid), whole blood (1% volume fraction) and fluorescein (0.16-10 μg/mL). Results show that the novel spectral analysis algorithm yields accurate estimates of tissue parameters independent of fluorescein concentration, with relative errors of blood volume fraction, blood oxygenation fraction (BOF), and the reduced scattering coefficient (at 521 nm) of <7%, <1%, and <22%, respectively. These data represent a first step towards quantification of fluorescein in tissue in vivo.

  19. Iris Crypts Influence Dynamic Changes of Iris Volume.

    PubMed

    Chua, Jacqueline; Thakku, Sri Gowtham; Tun, Tin A; Nongpiur, Monisha E; Tan, Marcus Chiang Lee; Girard, Michael J A; Wong, Tien Yin; Quah, Joanne Hui Min; Aung, Tin; Cheng, Ching-Yu

    2016-10-01

    To determine the association of iris surface features with iris volume change after physiologic pupil dilation in adults. Cross-sectional observational study. Chinese adults aged ≥ 50 years without ocular diseases. Digital iris photographs were taken from eyes of each participant and graded for crypts (by number and size) and furrows (by number and circumferential extent) following a standardized grading scheme. Iris color was measured objectively, using the Commission Internationale de l'Eclairage (CIE) L* color parameter (higher value denoting lighter iris). The anterior segment was imaged by swept-source optical coherence tomography (SS-OCT) (Casia; Tomey, Nagoya, Japan) under bright light and dark room conditions. Iris volumes in light and dark conditions were measured with custom semiautomated software, and the change in iris volume was quantified. Associations of the change in iris volume after pupil dilation with underlying iris surface features in right eyes were assessed using linear regression analysis. Iris volume change after physiologic pupil dilation from light to dark condition. A total of 65 Chinese participants (mean age, 59.8±5.7 years) had gradable data for iris surface features. In light condition, higher iris crypt grade was associated independently with smaller iris volume (β [change in iris volume in millimeters per crypt grade increment] = -1.43, 95% confidence interval [CI], -2.26 to -0.59; P = 0.001) and greater reduction of iris volume on pupil dilation (β [change in iris volume in millimeters per crypt grade increment] = 0.23, 95% CI, 0.06-0.40; P = 0.010), adjusting for age, gender, presence of corneal arcus, and change in pupil size. Iris furrows and iris color were not associated with iris volume in light condition or change in iris volume (all P > 0.05). Although few Chinese persons have multiple crypts on their irides, irides with more crypts were significantly thinner and lost more volume on pupil dilation. In view that the latter feature is known to be protective for acute angle-closure attack, it is likely that the macroscopic and microscopic composition of the iris is a contributing feature to angle-closure disease. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  20. Computational Modeling to Limit the Impact Displays and Indicator Lights Have on Habitable Volume Operational Lighting Constraints

    NASA Technical Reports Server (NTRS)

    Clark, T. A.; Salazar, G. A.; Brainard, G. C.; Kolomenski, A.; Hanifin, J.; Schwin, B. M.

    2017-01-01

    NASA has demonstrated an interest in improving astronaut health and performance through the installment of a new lighting countermeasure on the International Space Station. The Solid State Lighting Assembly (SSLA) system is designed to positively influence astronaut health by providing a daily change to light spectrum to improve circadian entrainment. Unfortunately, existing NASA standards and requirements define ambient light level requirements for crew sleep and other tasks, yet the number of light-emitting diode (LED) indicators and displays within a habitable volume is currently uncontrolled. Because each of these light sources has its own unique spectral properties, the additive lighting environment ends up becoming something different from what was planned or researched. Restricting the use of displays and indicators is not a solution because these systems provide beneficial crew feedback.

  1. Male orthopaedic surgeons and anaesthetists: equally good at estimating fluid volumes (and changing light bulbs) but equally poor at estimating procedure duration.

    PubMed

    Chua, Weiliang; Kong, Chee Hoe; Murphy, Diarmuid Paul

    2015-05-01

    How many orthopods does it take to change a light bulb? One - to refer to the medics for 'Darkness ?Cause'. Additionally, anaesthetists and surgeons often disagree on the estimated blood loss during surgery and the estimated procedure duration. We designed this study to compare the ability of orthopaedic surgeons and anaesthetists in: (a) estimating fluid volumes; (b) estimating procedure durations; and (c) changing light bulbs. Participants had to either be a specialist in anaesthesia or orthopaedic surgery, or a trainee in that specialty for at least two years. Three different fluid specimens were used for volume estimation (44 mL, 88 mL and 144 mL). Two videos of different lengths (140 seconds and 170 seconds), showing the suturing of a banana skin, were used for procedure duration estimation. To determine the ability at changing light bulbs, the participants had to match eight different light sockets to their respective bulbs. 30 male anaesthetists and trainees and 31 male orthopaedic surgeons and trainees participated in this study. Orthopaedic surgeons underestimated the three fluid volumes by 3.9% and anaesthetists overestimated by 5.1% (p = 0.925). Anaesthetists and orthopaedic surgeons overestimated the duration of the two procedures by 21.2% and 43.1%, respectively (p = 0.006). Anaesthetists had a faster mean time in changing light bulbs (70.1 seconds vs. 74.1 seconds, p = 0.319). In an experimental environment, male orthopaedic surgeons are as good as male anaesthetists in estimating fluid volumes (in commonly seen surgical specimens) and in changing light bulbs. Both groups are poor at estimating procedure durations.

  2. Prediction of Packed Cell Volume after Whole Blood Transfusion in Small Ruminants and South American Camelids: 80 Cases (2006-2016).

    PubMed

    Luethy, D; Stefanovski, D; Salber, R; Sweeney, R W

    2017-11-01

    Calculation of desired whole blood transfusion volume relies on an estimate of an animal's circulating blood volume, generally accepted to be 0.08 L/kg or 8% of the animal's body weight in kilograms. To use packed cell volume before and after whole blood transfusion to evaluate the accuracy of a commonly used equation to predict packed cell volume after transfusion in small ruminants and South American camelids; to determine the nature and frequency of adverse transfusion reactions in small ruminants and camelids after whole blood transfusion. Fifty-eight small ruminants and 22 alpacas that received whole blood transfusions for anemia. Retrospective case series; medical record review for small ruminants and camelids that received whole blood transfusions during hospitalization. Mean volume of distribution of blood as a fraction of body weight in sheep (0.075 L/kg, 7.5% BW) and goats (0.076 L/kg, 7.6% BW) differed significantly (P < 0.01) from alpacas (0.103 L/kg, 10.3% BW). Mild transfusion reactions were noted in 16% of transfusions. The generally accepted value of 8% for circulating blood volume (volume of distribution of blood) is adequate for calculation of transfusion volumes; however, use of the species-specific circulating blood volume can improve calculation of transfusion volume to predict and achieve desired packed cell volume. The incidence of transfusion reactions in small ruminants and camelids is low. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  3. Estimating stem volume and biomass of Pinus koraiensis using LiDAR data.

    PubMed

    Kwak, Doo-Ahn; Lee, Woo-Kyun; Cho, Hyun-Kook; Lee, Seung-Ho; Son, Yowhan; Kafatos, Menas; Kim, So-Ra

    2010-07-01

    The objective of this study was to estimate the stem volume and biomass of individual trees using the crown geometric volume (CGV), which was extracted from small-footprint light detection and ranging (LiDAR) data. Attempts were made to analyze the stem volume and biomass of Korean Pine stands (Pinus koraiensis Sieb. et Zucc.) for three classes of tree density: low (240 N/ha), medium (370 N/ha), and high (1,340 N/ha). To delineate individual trees, extended maxima transformation and watershed segmentation of image processing methods were applied, as in one of our previous studies. As the next step, the crown base height (CBH) of individual trees has to be determined; information for this was found in the LiDAR point cloud data using k-means clustering. The LiDAR-derived CGV and stem volume can be estimated on the basis of the proportional relationship between the CGV and stem volume. As a result, low tree-density plots had the best performance for LiDAR-derived CBH, CGV, and stem volume (R (2) = 0.67, 0.57, and 0.68, respectively) and accuracy was lowest for high tree-density plots (R (2) = 0.48, 0.36, and 0.44, respectively). In the case of medium tree-density plots accuracy was R (2) = 0.51, 0.52, and 0.62, respectively. The LiDAR-derived stem biomass can be predicted from the stem volume using the wood basic density of coniferous trees (0.48 g/cm(3)), and the LiDAR-derived above-ground biomass can then be estimated from the stem volume using the biomass conversion and expansion factors (BCEF, 1.29) proposed by the Korea Forest Research Institute (KFRI).

  4. Coherence Volume of an Optical Wave Field with Broad Frequency and Angular Spectra

    NASA Astrophysics Data System (ADS)

    Lyakin, D. V.; Mysina, N. Yu.; Ryabukho, V. P.

    2018-03-01

    We consider the sizes of a region in a three-dimensional space in which an optical wave field excites mutually coherent perturbations. We discuss the conditions under which the length of this region along the direction of propagation of the wave field and, correspondingly, its volume are determined either by the width of the frequency spectrum of the field or by the width of its angular spectrum, or by the parameters of these spectra simultaneously. We obtain expressions for estimating extremely small values of the coherence volume of the fields with a broad frequency spectrum and an extremely broad angular spectrum. Using the notion of instantaneous speckle-modulation of the wave field, we give a physical interpretation to the occurrence of a limited coherence volume of the field. The length of the spatiotemporal coherence region in which mutually coherent perturbations occur at different times is determined. The coherence volume of a wave field that illuminates an object in high-resolution microscopy with frequency broadband light is considered. The conditions for the dominant influence of the angular or frequency spectra on the longitudinal length of the coherence region are given, and the conditions for the influence of the frequency spectrum width on the transverse coherence of the wave field are examined. We show that, when using fields with broad and ultrabroad spectra in high-resolution microscopy, this influence should be taken into account.

  5. Advanced freeform optics enabling ultra-compact VR headsets

    NASA Astrophysics Data System (ADS)

    Benitez, Pablo; Miñano, Juan C.; Zamora, Pablo; Grabovičkić, Dejan; Buljan, Marina; Narasimhan, Bharathwaj; Gorospe, Jorge; López, Jesús; Nikolić, Milena; Sánchez, Eduardo; Lastres, Carmen; Mohedano, Ruben

    2017-06-01

    We present novel advanced optical designs with a dramatically smaller display to eye distance, excellent image quality and a large field of view (FOV). This enables headsets to be much more compact, typically occupying about a fourth of the volume of a conventional headset with the same FOV. The design strategy of these optics is based on a multichannel approach, which reduces the distance from the eye to the display and the display size itself. Unlike conventional microlens arrays, which are also multichannel devices, our designs use freeform optical surfaces to produce excellent imaging quality in the entire field of view, even when operating at very oblique incidences. We present two families of compact solutions that use different types of lenslets: (1) refractive designs, whose lenslets are composed typically of two refractive surfaces each; and (2) light-folding designs that use prism-like three-surface lenslets, in which rays undergo refraction, reflection, total internal reflection and refraction again. The number of lenslets is not fixed, so different configurations may arise, adaptable for flat or curved displays with different aspect ratios. In the refractive designs the distance between the optics and the display decreases with the number of lenslets, allowing for displaying a light-field when the lenslet becomes significantly small than the eye pupil. On the other hand, the correlation between number of lenslets and the optics to display distance is broken in light-folding designs, since their geometry permits achieving a very short display to eye distance with even a small number of lenslets.

  6. Quantifying Golgi structure using EM: combining volume-SEM and stereology for higher throughput.

    PubMed

    Ferguson, Sophie; Steyer, Anna M; Mayhew, Terry M; Schwab, Yannick; Lucocq, John Milton

    2017-06-01

    Investigating organelles such as the Golgi complex depends increasingly on high-throughput quantitative morphological analyses from multiple experimental or genetic conditions. Light microscopy (LM) has been an effective tool for screening but fails to reveal fine details of Golgi structures such as vesicles, tubules and cisternae. Electron microscopy (EM) has sufficient resolution but traditional transmission EM (TEM) methods are slow and inefficient. Newer volume scanning EM (volume-SEM) methods now have the potential to speed up 3D analysis by automated sectioning and imaging. However, they produce large arrays of sections and/or images, which require labour-intensive 3D reconstruction for quantitation on limited cell numbers. Here, we show that the information storage, digital waste and workload involved in using volume-SEM can be reduced substantially using sampling-based stereology. Using the Golgi as an example, we describe how Golgi populations can be sensed quantitatively using single random slices and how accurate quantitative structural data on Golgi organelles of individual cells can be obtained using only 5-10 sections/images taken from a volume-SEM series (thereby sensing population parameters and cell-cell variability). The approach will be useful in techniques such as correlative LM and EM (CLEM) where small samples of cells are treated and where there may be variable responses. For Golgi study, we outline a series of stereological estimators that are suited to these analyses and suggest workflows, which have the potential to enhance the speed and relevance of data acquisition in volume-SEM.

  7. Data Base Development of Automobile and Light Truck Maintenance : Volume I. Test and Appendixes A-D

    DOT National Transportation Integrated Search

    1978-08-01

    The volume describes the development of the life cycle maintenance costs for 212 sales-leading 1970 through 1975 passenger cars and light trucks. These costs provide a data base for the Department of Transportation, which describes the costs for part...

  8. Hollow fibers for compact infrared gas sensors

    NASA Astrophysics Data System (ADS)

    Lambrecht, A.; Hartwig, S.; Herbst, J.; Wöllenstein, J.

    2008-02-01

    Hollow fibers can be used for compact infrared gas sensors. The guided light is absorbed by the gas introduced into the hollow core. High sensitivity and a very small sampling volume can be achieved depending on fiber parameters i.e. attenuation, flexibility, and gas exchange rates. Different types of infrared hollow fibers including photonic bandgap fibers were characterized using quantum cascade lasers and thermal radiation sources. Obtained data are compared with available product specifications. Measurements with a compact fiber based ethanol sensor are compared with a system simulation. First results on the detection of trace amounts of the explosive material TATP using hollow fibers and QCL will be shown.

  9. Ultracompact low-threshold organic laser.

    PubMed

    Deotare, Parag B; Mahony, Thomas S; Bulović, Vladimir

    2014-11-25

    We report an ultracompact low-threshold laser with an Alq3:DCM host:guest molecular organic thin film gain layer. The device uses a photonic crystal nanobeam cavity which provides a high quality factor to mode volume (Q/V) ratio and increased spontaneous emission factor along with a small footprint. Lasing is observed with a threshold of 4.2 μJ/cm(2) when pumped by femtosecond pulses of λ = 400 nm wavelength light. We also model the dynamics of the laser and show good agreement with the experimental data. The inherent waveguide geometry of the structure enables easy on-chip integration with potential applications in biochemical sensing, inertial sensors, and data communication.

  10. Conjugate adaptive optics with remote focusing in multiphoton microscopy

    NASA Astrophysics Data System (ADS)

    Tao, Xiaodong; Lam, Tuwin; Zhu, Bingzhao; Li, Qinggele; Reinig, Marc R.; Kubby, Joel

    2018-02-01

    The small correction volume for conventional wavefront shaping methods limits their application in biological imaging through scattering media. In this paper, we take advantage of conjugate adaptive optics (CAO) and remote focusing (CAORF) to achieve three-dimensional (3D) scanning through a scattering layer with a single correction. Our results show that the proposed system can provide 10 times wider axial field of view compared with a conventional conjugate AO system when 16,384 segments are used on a spatial light modulator. We demonstrate two-photon imaging with CAORF through mouse skull. The fluorescent microspheres embedded under the scattering layers can be clearly observed after applying the correction.

  11. Multispectral imaging probe

    DOEpatents

    Sandison, David R.; Platzbecker, Mark R.; Descour, Michael R.; Armour, David L.; Craig, Marcus J.; Richards-Kortum, Rebecca

    1999-01-01

    A multispectral imaging probe delivers a range of wavelengths of excitation light to a target and collects a range of expressed light wavelengths. The multispectral imaging probe is adapted for mobile use and use in confined spaces, and is sealed against the effects of hostile environments. The multispectral imaging probe comprises a housing that defines a sealed volume that is substantially sealed from the surrounding environment. A beam splitting device mounts within the sealed volume. Excitation light is directed to the beam splitting device, which directs the excitation light to a target. Expressed light from the target reaches the beam splitting device along a path coaxial with the path traveled by the excitation light from the beam splitting device to the target. The beam splitting device directs expressed light to a collection subsystem for delivery to a detector.

  12. Multispectral imaging probe

    DOEpatents

    Sandison, D.R.; Platzbecker, M.R.; Descour, M.R.; Armour, D.L.; Craig, M.J.; Richards-Kortum, R.

    1999-07-27

    A multispectral imaging probe delivers a range of wavelengths of excitation light to a target and collects a range of expressed light wavelengths. The multispectral imaging probe is adapted for mobile use and use in confined spaces, and is sealed against the effects of hostile environments. The multispectral imaging probe comprises a housing that defines a sealed volume that is substantially sealed from the surrounding environment. A beam splitting device mounts within the sealed volume. Excitation light is directed to the beam splitting device, which directs the excitation light to a target. Expressed light from the target reaches the beam splitting device along a path coaxial with the path traveled by the excitation light from the beam splitting device to the target. The beam splitting device directs expressed light to a collection subsystem for delivery to a detector. 8 figs.

  13. 3-D Flow Visualization with a Light-field Camera

    NASA Astrophysics Data System (ADS)

    Thurow, B.

    2012-12-01

    Light-field cameras have received attention recently due to their ability to acquire photographs that can be computationally refocused after they have been acquired. In this work, we describe the development of a light-field camera system for 3D visualization of turbulent flows. The camera developed in our lab, also known as a plenoptic camera, uses an array of microlenses mounted next to an image sensor to resolve both the position and angle of light rays incident upon the camera. For flow visualization, the flow field is seeded with small particles that follow the fluid's motion and are imaged using the camera and a pulsed light source. The tomographic MART algorithm is then applied to the light-field data in order to reconstruct a 3D volume of the instantaneous particle field. 3D, 3C velocity vectors are then determined from a pair of 3D particle fields using conventional cross-correlation algorithms. As an illustration of the concept, 3D/3C velocity measurements of a turbulent boundary layer produced on the wall of a conventional wind tunnel are presented. Future experiments are planned to use the camera to study the influence of wall permeability on the 3-D structure of the turbulent boundary layer.Schematic illustrating the concept of a plenoptic camera where each pixel represents both the position and angle of light rays entering the camera. This information can be used to computationally refocus an image after it has been acquired. Instantaneous 3D velocity field of a turbulent boundary layer determined using light-field data captured by a plenoptic camera.

  14. Wave optics theory and 3-D deconvolution for the light field microscope

    PubMed Central

    Broxton, Michael; Grosenick, Logan; Yang, Samuel; Cohen, Noy; Andalman, Aaron; Deisseroth, Karl; Levoy, Marc

    2013-01-01

    Light field microscopy is a new technique for high-speed volumetric imaging of weakly scattering or fluorescent specimens. It employs an array of microlenses to trade off spatial resolution against angular resolution, thereby allowing a 4-D light field to be captured using a single photographic exposure without the need for scanning. The recorded light field can then be used to computationally reconstruct a full volume. In this paper, we present an optical model for light field microscopy based on wave optics, instead of previously reported ray optics models. We also present a 3-D deconvolution method for light field microscopy that is able to reconstruct volumes at higher spatial resolution, and with better optical sectioning, than previously reported. To accomplish this, we take advantage of the dense spatio-angular sampling provided by a microlens array at axial positions away from the native object plane. This dense sampling permits us to decode aliasing present in the light field to reconstruct high-frequency information. We formulate our method as an inverse problem for reconstructing the 3-D volume, which we solve using a GPU-accelerated iterative algorithm. Theoretical limits on the depth-dependent lateral resolution of the reconstructed volumes are derived. We show that these limits are in good agreement with experimental results on a standard USAF 1951 resolution target. Finally, we present 3-D reconstructions of pollen grains that demonstrate the improvements in fidelity made possible by our method. PMID:24150383

  15. Particle sizing by weighted measurements of scattered light

    NASA Technical Reports Server (NTRS)

    Buchele, Donald R.

    1988-01-01

    A description is given of a measurement method, applicable to a poly-dispersion of particles, in which the intensity of scattered light at any angle is weighted by a factor proportional to that angle. Determination is then made of four angles at which the weighted intensity is four fractions of the maximum intensity. These yield four characteristic diameters, i.e., the diameters of the volume/area mean (D sub 32 the Sauter mean) and the volume/diameter mean (D sub 31); the diameters at cumulative volume fractions of 0.5 (D sub v0.5 the volume median) and 0.75 (D sub v0.75). They also yield the volume dispersion of diameters. Mie scattering computations show that an average diameter less than three micrometers cannot be accurately measured. The results are relatively insensitive to extraneous background light and to the nature of the diameter distribution. Also described is an experimental method of verifying the conclusions by using two microscopic slides coated with polystyrene microspheres to simulate the particles and the background.

  16. Development Of Nonimaging Optics

    NASA Astrophysics Data System (ADS)

    Winston, Roland

    1984-01-01

    This paper is concerned with the new field of nonimaging optics. Roughly this may be defined as the collection and redirection of light (or, more generally, electromagnetic radiation) by means of optical systems which do not make use of image formation concepts in their design. A non-trivial example is the compound parabolic concentrator (CPC) invented in 1965 for collecting Cerenkov radiation from large volumes of gas and concentrating it onto the relatively small area of a photomultiplier cathode. This task would, according to conventional optical practice, be performed by a lens or mirror image-forming system of high numerical aperture, but much greater concentration was achieved by a comparatively simple de-vice, the CPC. The key was to abandon the principle of imaging with high numerical aperture and instead to get the collected rays into as small an area as possible without attempting to produce an image.

  17. Pre-Capture Privacy for Small Vision Sensors.

    PubMed

    Pittaluga, Francesco; Koppal, Sanjeev Jagannatha

    2017-11-01

    The next wave of micro and nano devices will create a world with trillions of small networked cameras. This will lead to increased concerns about privacy and security. Most privacy preserving algorithms for computer vision are applied after image/video data has been captured. We propose to use privacy preserving optics that filter or block sensitive information directly from the incident light-field before sensor measurements are made, adding a new layer of privacy. In addition to balancing the privacy and utility of the captured data, we address trade-offs unique to miniature vision sensors, such as achieving high-quality field-of-view and resolution within the constraints of mass and volume. Our privacy preserving optics enable applications such as depth sensing, full-body motion tracking, people counting, blob detection and privacy preserving face recognition. While we demonstrate applications on macro-scale devices (smartphones, webcams, etc.) our theory has impact for smaller devices.

  18. 40 CFR 1054.635 - What special provisions apply for small-volume engine and equipment manufacturers?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... special provisions in this part for small-volume engine and equipment manufacturers. (a) If you qualify... qualify under paragraph (1) or (2) of the definition of small-volume engine manufacturer or under...) Additional lead time and other provisions related to the transition to new emission standards. See § 1054.145...

  19. Ring-Interferometric Sol-Gel Bio-Sensor

    NASA Technical Reports Server (NTRS)

    Bearman, Gregory (Inventor); Cohen, David (Inventor)

    2006-01-01

    A biosensor embodying the invention includes a sensing volume having an array of pores sized for immobilizing a first biological entity tending to bind to a second biological entity in such a manner as to change an index of refraction of the sensing volume. The biosensor further includes a ring interferometer, one volumetric section of the ring interferometer being the sensing volume, a laser for supplying light to the ring interferometer, and a photodetector for receiving light from the interferometer.

  20. Molecular Volumes and the Stokes-Einstein Equation

    ERIC Educational Resources Information Center

    Edward, John T.

    1970-01-01

    Examines the limitations of the Stokes-Einstein equation as it applies to small solute molecules. Discusses molecular volume determinations by atomic increments, molecular models, molar volumes of solids and liquids, and molal volumes. Presents an empirical correction factor for the equation which applies to molecular radii as small as 2 angstrom…

  1. Bidirectional light-scattering image processing method for high-concentration jet sprays

    NASA Astrophysics Data System (ADS)

    Shimizu, I.; Emori, Y.; Yang, W.-J.; Shimoda, M.; Suzuki, T.

    1985-01-01

    In order to study the distributions of droplet size and volume density in high-concentration jet sprays, a new technique is developed, which combines the forward and backward light scattering method and an image processing method. A pulsed ruby laser is used as the light source. The Mie scattering theory is applied to the results obtained from image processing on the scattering photographs. The time history is obtained for the droplet size and volume density distributions, and the method is demonstrated by diesel fuel sprays under various injecting conditions. The validity of the technique is verified by a good agreement in the injected fuel volume distributions obtained by the present method and by injection rate measurements.

  2. A generalized quantitative interpretation of dark-field contrast for highly concentrated microsphere suspensions

    PubMed Central

    Gkoumas, Spyridon; Villanueva-Perez, Pablo; Wang, Zhentian; Romano, Lucia; Abis, Matteo; Stampanoni, Marco

    2016-01-01

    In X-ray grating interferometry, dark-field contrast arises due to partial extinction of the detected interference fringes. This is also called visibility reduction and is attributed to small-angle scattering from unresolved structures in the imaged object. In recent years, analytical quantitative frameworks of dark-field contrast have been developed for highly diluted monodisperse microsphere suspensions with maximum 6% volume fraction. These frameworks assume that scattering particles are separated by large enough distances, which make any interparticle scattering interference negligible. In this paper, we start from the small-angle scattering intensity equation and, by linking Fourier and real-space, we introduce the structure factor and thus extend the analytical and experimental quantitative interpretation of dark-field contrast, for a range of suspensions with volume fractions reaching 40%. The structure factor accounts for interparticle scattering interference. Without introducing any additional fitting parameters, we successfully predict the experimental values measured at the TOMCAT beamline, Swiss Light Source. Finally, we apply this theoretical framework to an experiment probing a range of system correlation lengths by acquiring dark-field images at different energies. This proposed method has the potential to be applied in single-shot-mode using a polychromatic X-ray tube setup and a single-photon-counting energy-resolving detector. PMID:27734931

  3. How To Set Up Your Own Small Business. Volumes I-II and Overhead Transparencies.

    ERIC Educational Resources Information Center

    Fallek, Max

    This two-volume textbook and collection of overhead transparency masters is intended for use in a course in setting up a small business. The following topics are covered in the first volume: getting off to a good start, doing market research, forecasting sales, financing a small business, understanding the different legal needs of different types…

  4. A method of measuring a molten metal liquid pool volume

    DOEpatents

    Garcia, G.V.; Carlson, N.M., Donaldson, A.D.

    1990-12-12

    A method of measuring a molten metal liquid pool volume and in particular molten titanium liquid pools, including the steps of (a) generating an ultrasonic wave at the surface of the molten metal liquid pool, (b) shining a light on the surface of a molten metal liquid pool, (c) detecting a change in the frequency of light, (d) detecting an ultrasonic wave echo at the surface of the molten metal liquid pool, and (e) computing the volume of the molten metal liquid. 3 figs.

  5. Method of measuring a liquid pool volume

    DOEpatents

    Garcia, G.V.; Carlson, N.M.; Donaldson, A.D.

    1991-03-19

    A method of measuring a molten metal liquid pool volume and in particular molten titanium liquid pools is disclosed, including the steps of (a) generating an ultrasonic wave at the surface of the molten metal liquid pool, (b) shining a light on the surface of a molten metal liquid pool, (c) detecting a change in the frequency of light, (d) detecting an ultrasonic wave echo at the surface of the molten metal liquid pool, and (e) computing the volume of the molten metal liquid. 3 figures.

  6. Method of measuring a liquid pool volume

    DOEpatents

    Garcia, Gabe V.; Carlson, Nancy M.; Donaldson, Alan D.

    1991-01-01

    A method of measuring a molten metal liquid pool volume and in particular molten titanium liquid pools, including the steps of (a) generating an ultrasonic wave at the surface of the molten metal liquid pool, (b) shining a light on the surface of a molten metal liquid pool, (c) detecting a change in the frequency of light, (d) detecting an ultrasonic wave echo at the surface of the molten metal liquid pool, and (e) computing the volume of the molten metal liquid.

  7. Exact finite volume expectation values of \\overline{Ψ}Ψ in the massive Thirring model from light-cone lattice correlators

    NASA Astrophysics Data System (ADS)

    Hegedűs, Árpád

    2018-03-01

    In this paper, using the light-cone lattice regularization, we compute the finite volume expectation values of the composite operator \\overline{Ψ}Ψ between pure fermion states in the Massive Thirring Model. In the light-cone regularized picture, this expectation value is related to 2-point functions of lattice spin operators being located at neighboring sites of the lattice. The operator \\overline{Ψ}Ψ is proportional to the trace of the stress-energy tensor. This is why the continuum finite volume expectation values can be computed also from the set of non-linear integral equations (NLIE) governing the finite volume spectrum of the theory. Our results for the expectation values coming from the computation of lattice correlators agree with those of the NLIE computations. Previous conjectures for the LeClair-Mussardo-type series representation of the expectation values are also checked.

  8. Volume estimation of small phantoms and rat kidneys using three-dimensional ultrasonography and a position sensor.

    PubMed

    Strømmen, Kenneth; Stormark, Tor André; Iversen, Bjarne M; Matre, Knut

    2004-09-01

    To evaluate the accuracy of small volume estimation, both in vivo and in vitro, measurements with a three-dimensional (3D) ultrasound (US) system were carried out. A position sensor was used and the transmitting frequency was 10 MHz. Balloons with known volumes were scanned while rat kidneys were scanned in vivo and in vitro. The Archimedes' principle was used to estimate the true volume. For balloons, the 3D US system gave very good agreement with true volumes in the volume range 0.1 to 10.0 mL (r = 0.999, n = 45, mean difference +/- 2SD = 0.245 +/- 0.370 mL). For rat kidneys in vivo (volume range 0.6 to 2.7 mL) the method was less accurate (r = 0.800, n = 10, mean difference +/- 2SD = -0.288 +/- 0.676 mL). For rat kidneys in vitro (volume range 0.3 to 2.7 mL) the results showed good agreement (r = 0.981, n = 23, mean difference +/- 2SD = 0.039 +/- 0.254 mL). For balloons, kidneys in vivo and in vitro, the mean percentage error was 9.3 +/- 4.8%, -17.1 +/- 17.4%, and 4.6 +/- 11.5%, respectively. This method can estimate the volume of small phantoms and rat kidneys and opens new possibilities for volume measurements of small objects and the study of organ function in small animals. (E-mail ).

  9. Influence of three artificial light sources on oviposition and half-life of the Black Soldier Fly, Hermetia illucens (Diptera: Stratiomyidae): Improving small-scale indoor rearing.

    PubMed

    Heussler, Carina D; Walter, Andreas; Oberkofler, Hannes; Insam, Heribert; Arthofer, Wolfgang; Schlick-Steiner, Birgit C; Steiner, Florian M

    2018-01-01

    Hermetia illucens (L.), the Black Soldier Fly, has received increased scientific attention for its potential in circular waste management where larvae can serve as feedstuff for livestock and for biodiesel production. The flies occur naturally in (sub)-tropical and warm-temperate climates, and their mating depends on space and sunlight. Small-scale indoor rearing of Black Soldier Flies has been challenging because they react sensitive to artificial light sources and cage sizes, but recent studies have shown that small-scale rearing under artificial light is feasible. Here, we test the influence of three artificial light sources (light-emitting diodes, fluorescent lamps, and halogen lamps) on small-scale indoor rearing. Three experiments were conducted to compare oviposition traits (pre-oviposition period, total oviposition-period, and egg mass per female) and half-life among the three light sources. Oviposition did not differ among the three light sources, but male and female half-life did. Based on the performance of the light-emitting diodes and their outstanding energy efficiency, we recommend this light source for small-scale indoor rearing of Black Soldier Flies.

  10. Plasticity in mesophyll volume fraction modulates light-acclimation in needle photosynthesis in two pines.

    PubMed

    Niinemets, Ulo; Lukjanova, Aljona; Turnbull, Matthew H; Sparrow, Ashley D

    2007-08-01

    Acclimation potential of needle photosynthetic capacity varies greatly among pine species, but the underlying chemical, anatomical and morphological controls are not entirely understood. We investigated the light-dependent variation in needle characteristics in individuals of Pinus patula Schlect. & Cham., which has 19-31-cm long pendulous needles, and individuals of P. radiata D. Don., which has shorter (8-17-cm-long) stiffer needles. Needle nitrogen and carbon contents, mesophyll and structural tissue volume fractions, needle dry mass per unit total area (M(A)) and its components, volume to total area ratio (V/A(T)) and needle density (D = M(A)/(V/A(T))), and maximum carboxylase activity of Rubisco (V(cmax)) and capacity of photosynthetic electron transport (J(max)) were investigated in relation to seasonal mean integrated irradiance (Q(int)). Increases in Q(int) from canopy bottom to top resulted in proportional increases in both needle thickness and width such that needle total to projected surface area ratio, characterizing the efficiency of light interception, was independent of Q(int). Increased light availability also led to larger M(A) and nitrogen content per unit area (N(A)). Light-dependent modifications in M(A) resulted from increases in both V/A(T) and D, whereas N(A) changed because of increases in both M(A) and mass-based nitrogen content (N(M)) (N(A) = N(M)M(A)). Overall, the volume fraction of mesophyll cells increased with increasing irradiance and V/A(T) as the fraction of hypodermis and epidermis decreased with increasing needle thickness. Increases in M(A) and N(A) resulted in enhanced J(max) and V(cmax) per unit area in both species, but mass-based photosynthetic capacity increased only in P. patula. In addition, J(max) and V(cmax) showed greater plasticity in response to light in P. patula. Species differences in mesophyll volume fraction explained most of the variation in mass-based needle photosynthetic capacity between species, demonstrating that differences in plastic adjustments in mass-based photosynthetic activities among these representative individuals were mainly associated with contrasting investments in mesophyll cells. Greater area-based photosynthetic plasticity in P. patula relative to P. radiata was associated with larger increases in M(A) and mesophyll volume fraction with increasing irradiance. These data collectively demonstrate that light-dependent increases in mass-based nitrogen contents and photosynthetic activities were associated with an increased mesophyll volume fraction in needles at higher irradiances. They also emphasize the importance of light-dependent anatomical modifications in determining needle photosynthetic capacity.

  11. Disrupting Illicit Small Arms Trafficking in the Middle East

    DTIC Science & Technology

    2008-12-01

    personal use and light weapons as weapons designed for use by a crew. Small arms include revolvers, self-loading pistols, rifles, sub- machine guns...assault rifles, and light machine guns. Light weapons include machine -guns, mortars, hand grenades, grenade launchers, portable anti-aircraft guns...71 David Atwood , Anne-Katherin Glatz, and Robert Muggah, Demanding Attention: Addressing the Dynamics of Small Arms Demand (Geneva: Small Arms

  12. Small tractors for harvesting fuelwood in low-volume small-diameter hardwood stands

    Treesearch

    Neil K. Huyler; Chris B. LeDoux

    1989-01-01

    Much of the nonindustrial, private forest land in the Northeast is characterized by small diameter trees with low volume. Conventional harvesting systems used in logging these stands generally results in submarginal economic returns. Often, small-scale harvesting systems have economic advantages in these areas. Time and motion studies were conducted for several small...

  13. Method for preparing small volume reaction containers

    DOEpatents

    Retterer, Scott T.; Doktycz, Mitchel J.

    2017-04-25

    Engineered reaction containers that can be physically and chemically defined to control the flux of molecules of different sizes and charge are disclosed. Methods for constructing small volume reaction containers through a combination of etching and deposition are also disclosed. The methods allow for the fabrication of multiple devices that possess features on multiple length scales, specifically small volume containers with controlled porosity on the nanoscale.

  14. Diurnal Patterns of Direct Light Extinction in Two Tropical Forest Canopies

    NASA Astrophysics Data System (ADS)

    Cushman, K.; Silva, C. E.; Kellner, J. R.

    2016-12-01

    The extent to which net ecosystem production is light-limited in Neotropical forests is poorly understood. This is due in part to our limited knowledge of how light moves through complex canopies to different layers of leaves, and the extent to which structural changes in canopies modify the amount of light absorbed by the landscape to drive photosynthesis. Systematic diurnal changes in solar angle, leaf angle, and wind speed suggest that patterns of light attenuation change over the course of the day in tropical forests. In this study, we characterize the extinction of direct light through the canopies of two forests in Panama using high-resolution, three-dimensional measurements from a small footprint, discrete return airborne laser scanner mounted on the gondola of a canopy crane. We hypothesized that light penetrates deeper into canopies during the middle of the day because changes in leaf angle by light-saturated leaves temporarily reduce effective canopy leaf area, and because greater wind speeds increase sunflecks. Also, we hypothesized that rates of light extinction are greater in the wetter forest that receives less direct sunlight because light saturation in upper leaves is less prevalent. We collected laser measurements with resolution of approximately 5,000 points per square meter of ground every 90 minutes over the course of one day each at Parque Natural Metropolitano (1740 mm annual rainfall) and Parque Nacional San Lorenzo (3300 mm annual rainfall) during the dry season in April, 2016. Using a voxel-based approach, we compared the actual versus potential distance traveled by laser beams through each volume of the canopy. We fit an exponential model to quantify the rate of light extinction. We found that rates of light extinction vary spatially, temporally, and by site. These results indicate that variation in forest structure changes patterns of light attenuation through the canopy over multiple scales.

  15. Small Business Management and Ownership. Volume Four. Mini-Problems in Entrepreneurship.

    ERIC Educational Resources Information Center

    Shuchat, Jo

    The mini-problems presented in this volume are provided to augment the introductory course, "Minding Your Own Small Business," and the advanced course, "Something Ventured, Something Gained," in small business ownership and management. They can also be used in conjunction with other instructional materials in small business…

  16. Surface area-volume ratios in insects.

    PubMed

    Kühsel, Sara; Brückner, Adrian; Schmelzle, Sebastian; Heethoff, Michael; Blüthgen, Nico

    2017-10-01

    Body mass, volume and surface area are important for many aspects of the physiology and performance of species. Whereas body mass scaling received a lot of attention in the literature, surface areas of animals have not been measured explicitly in this context. We quantified surface area-volume (SA/V) ratios for the first time using 3D surface models based on a structured light scanning method for 126 species of pollinating insects from 4 orders (Diptera, Hymenoptera, Lepidoptera, and Coleoptera). Water loss of 67 species was measured gravimetrically at very dry conditions for 2 h at 15 and 30 °C to demonstrate the applicability of the new 3D surface measurements and relevance for predicting the performance of insects. Quantified SA/V ratios significantly explained the variation in water loss across species, both directly or after accounting for isometric scaling (residuals of the SA/V ∼ mass 2/3 relationship). Small insects with a proportionally larger surface area had the highest water loss rates. Surface scans of insects to quantify allometric SA/V ratios thus provide a promising method to predict physiological responses, improving the potential of body mass isometry alone that assume geometric similarity. © 2016 Institute of Zoology, Chinese Academy of Sciences.

  17. Tribology of steel/steel interaction in oil-in-water emulsion; a rationale for lubricity.

    PubMed

    Kumar, Deepak; Daniel, Jency; Biswas, S K

    2010-05-15

    Oil droplets are dispersed in water by an anionic surfactant to form an emulsion. The lubricity of this emulsion in steel/steel interaction is explored in a ball on flat nanotribometer. The droplet size and charge are measured using dynamic light scattering, while the substrate charge density is estimated using the pH titration method. These data are combined to calculate the DLVO forces for the droplets generated for a range of surfactant concentration and two oil to water volume ratios. The droplets have a clear bi-modal size distribution. The study shows that the smaller droplets which experience weak repulsion are situated (at the highest DLVO barrier) much closer to the substrate than the bigger droplets, which experience the same DLVO force, are. We suggest that the smaller droplets thus play a more important role in lubricity than what the bigger droplets do. The largest volume of such small droplets occurs in the 0.5 mM-1 mM range of surfactant concentration and 1% oil to water volume ratio, where the coefficient of friction is also observed to be the least. Copyright © 2010 Elsevier Inc. All rights reserved.

  18. Sizing protein-templated gold nanoclusters by time resolved fluorescence anisotropy decay measurements

    NASA Astrophysics Data System (ADS)

    Soleilhac, Antonin; Bertorelle, Franck; Antoine, Rodolphe

    2018-03-01

    Protein-templated gold nanoclusters (AuNCs) are very attractive due to their unique fluorescence properties. A major problem however may arise due to protein structure changes upon the nucleation of an AuNC within the protein for any future use as in vivo probes, for instance. In this work, we propose a simple and reliable fluorescence based technique measuring the hydrodynamic size of protein-templated gold nanoclusters. This technique uses the relation between the time resolved fluorescence anisotropy decay and the hydrodynamic volume, through the rotational correlation time. We determine the molecular size of protein-directed AuNCs, with protein templates of increasing sizes, e.g. insulin, lysozyme, and bovine serum albumin (BSA). The comparison of sizes obtained by other techniques (e.g. dynamic light scattering and small-angle X-ray scattering) between bare and gold clusters containing proteins allows us to address the volume changes induced either by conformational changes (for BSA) or the formation of protein dimers (for insulin and lysozyme) during cluster formation and incorporation.

  19. Study on effective thermal conductivity of silicone/phosphor composite and its size effect by Lattice Boltzmann method

    NASA Astrophysics Data System (ADS)

    Li, Lan; Zheng, Huai; Yuan, Chao; Hu, Run; Luo, Xiaobing

    2016-12-01

    The silicone/phosphor composite is widely used in light emitting diode (LED) packaging. The composite thermal properties, especially the effective thermal conductivity, strongly influence the LED performance. In this paper, a lattice Boltzmann model was presented to predict the silicone/phosphor composite effective thermal conductivity. Based on the present lattice Boltzmann model, a random generation method was established to describe the phosphor particle distribution in composite. Benchmarks were conducted by comparing the simulation results with theoretical solutions for simple cases. Then the model was applied to analyze the effective thermal conductivity of the silicone/phosphor composite and its size effect. The deviations between simulation and experimental results are <7 %, when the phosphor volume fraction varies from 0.038 to 0.45. The simulation results also indicate that effective thermal conductivity of the composite with larger particles is higher than that with small particles at the same volume fraction. While mixing these two sizes of phosphor particles provides an extra enhancement for the effective thermal conductivity.

  20. Exploring growth conditions and Eu2+ concentration effects for KSr2I5:Eu scintillator crystals II: Ø 25 mm crystals

    NASA Astrophysics Data System (ADS)

    Stand, L.; Zhuravleva, M.; Johnson, J.; Koschan, M.; Wu, Y.; Donnald, S.; Vaigneur, K.; Lukosi, E.; Melcher, C. L.

    2018-02-01

    Europium doped potassium strontium iodide is a very promising scintillator for national security applications due to its ease of growth and excellent scintillation properties. For this work the fast crystal growth and scintillation properties of 1-inch diameter single crystals of KSr2I5:Eu2+ (KSI:Eu) were investigated. We focused our efforts on optimizing the growth parameters required to produce one-inch diameter crystals without decreasing the previously reported fast pulling rate of 5 mm/h. Cracking was minimized by replacing the quartz ampoules with carbon coated quartz ampoules; thus, several crack free single crystals of KSI with varying Eu2+ concentrations were grown, including a Ø 1″ by 6″ long boule with 2.5% Eu. The maximum achievable performance of each crystal was measured using small 0.012 cm3 specimens. The volumetric dependencies of the light yield, energy resolution and decay time were evaluated using KSI:Eu 2% specimens with volumes ranging from 0.012 cm3 to 18 cm3. For large volumes (≥ 9 cm3), the performance was comparable to other high performing scintillators, with light yields up to 78,200 ph/MeV and energy resolutions as good as 3.2% at 662 keV. The initial version of a hermetic package has been developed, and the stability of the sealed crystal is promising.

  1. Gamma bang time/reaction history diagnostics for the National Ignition Facility using 90 degrees off-axis parabolic mirrors.

    PubMed

    Malone, R M; Herrmann, H W; Stoeffl, W; Mack, J M; Young, C S

    2008-10-01

    Gas Cherenkov detectors (GCDs) have been used to convert fusion gamma into photons to achieve gamma bang time and reaction history measurements. The GCDs designed for OMEGA used Cassegrain reflector optics in order to fit inside a 10 in. manipulator. A novel design for the National Ignition Facility using 90 degrees off-axis parabolic mirrors will increase light collection efficiency from fusion gammas and achieve minimum time dispersion. The broadband Cherenkov light (from 200 to 800 nm) is relayed into a high-speed detector using three parabolic mirrors. Because light is collected from many source planes throughout the CO(2) gas volume, the detector is positioned at the stop position rather than at an image position. The stop diameter and its position are independent of the light-generation location along the gas cell. The current design collects light from a 100 mm diameter by 500 mm long gas volume. Optical ray tracings demonstrate how light can be collected from different angled trajectories of the Compton electrons as they fly through the CO(2) gas volume. A cluster of four channels will allow for increased dynamic range as well as for different gamma energy threshold sensitivities.

  2. Tailoring light-matter coupling in semiconductor and hybrid-plasmonic nanowires

    PubMed Central

    Piccione, Brian; Aspetti, Carlos O.; Cho, Chang-Hee; Agarwal, Ritesh

    2014-01-01

    Understanding interactions between light and matter is central to many fields, providing invaluable insights into the nature of matter. In its own right, a greater understanding of light-matter coupling has allowed for the creation of tailored applications, resulting in a variety of devices such as lasers, switches, sensors, modulators, and detectors. Reduction of optical mode volume is crucial to enhancing light-matter coupling strength, and among solid-state systems, self-assembled semiconductor and hybrid-plasmonic nanowires are amenable to creation of highly-confined optical modes. Following development of unique spectroscopic techniques designed for the nanowire morphology, carefully engineered semiconductor nanowire cavities have recently been tailored to enhance light-matter coupling strength in a manner previously seen in optical microcavities. Much smaller mode volumes in tailored hybrid-plasmonic nanowires have recently allowed for similar breakthroughs, resulting in sub-picosecond excited-state lifetimes and exceptionally high radiative rate enhancement. Here, we review literature on light-matter interactions in semiconductor and hybrid-plasmonic monolithic nanowire optical cavities to highlight recent progress made in tailoring light-matter coupling strengths. Beginning with a discussion of relevant concepts from optical physics, we will discuss how our knowledge of light-matter coupling has evolved with our ability to produce ever-shrinking optical mode volumes, shifting focus from bulk materials to optical microcavities, before moving on to recent results obtained from semiconducting nanowires. PMID:25093385

  3. Three-dimensional dosimetry of small megavoltage radiation fields using radiochromic gels and optical CT scanning

    NASA Astrophysics Data System (ADS)

    Babic, Steven; McNiven, Andrea; Battista, Jerry; Jordan, Kevin

    2009-04-01

    The dosimetry of small fields as used in stereotactic radiotherapy, radiosurgery and intensity-modulated radiation therapy can be challenging and inaccurate due to partial volume averaging effects and possible disruption of charged particle equilibrium. Consequently, there exists a need for an integrating, tissue equivalent dosimeter with high spatial resolution to avoid perturbing the radiation beam and artificially broadening the measured beam penumbra. In this work, radiochromic ferrous xylenol-orange (FX) and leuco crystal violet (LCV) micelle gels were used to measure relative dose factors (RDFs), percent depth dose profiles and relative lateral beam profiles of 6 MV x-ray pencil beams of diameter 28.1, 9.8 and 4.9 mm. The pencil beams were produced via stereotactic collimators mounted on a Varian 2100 EX linear accelerator. The gels were read using optical computed tomography (CT). Data sets were compared quantitatively with dosimetric measurements made with radiographic (Kodak EDR2) and radiochromic (GAFChromic® EBT) film, respectively. Using a fast cone-beam optical CT scanner (Vista™), corrections for diffusion in the FX gel data yielded RDFs that were comparable to those obtained by minimally diffusing LCV gels. Considering EBT film-measured RDF data as reference, cone-beam CT-scanned LCV gel data, corrected for scattered stray light, were found to be in agreement within 0.5% and -0.6% for the 9.8 and 4.9 mm diameter fields, respectively. The validity of the scattered stray light correction was confirmed by general agreement with RDF data obtained from the same LCV gel read out with a laser CT scanner that is less prone to the acceptance of scattered stray light. Percent depth dose profiles and lateral beam profiles were found to agree within experimental error for the FX gel (corrected for diffusion), LCV gel (corrected for scattered stray light), and EBT and EDR2 films. The results from this study reveal that a three-dimensional dosimetry method utilizing optical CT-scanned radiochromic gels allows for the acquisition of a self-consistent volumetric data set in a single exposure, with sufficient spatial resolution to accurately characterize small fields.

  4. [A review of mixed gas detection system based on infrared spectroscopic technique].

    PubMed

    Dang, Jing-Min; Fu, Li; Yan, Zi-Hui; Zheng, Chuan-Tao; Chang, Yu-Chun; Chen, Chen; Wang, Yi-Din

    2014-10-01

    In order to provide the experiences and references to the researchers who are working on infrared (IR) mixed gas detection field. The proposed manuscript reviews two sections of the aforementioned field, including optical multiplexing structure and detection method. At present, the coherent light sources whose representative are quantum cascade laser (QCL) and inter-band cascade laser(ICL) become the mainstream light source in IR mixed gas detection, which replace the traditional non-coherent light source, such as IR radiation source and IR light emitting diode. In addition, the photon detector which has a super high detectivity and very short response time is gradually beyond thermal infrared detector, dominant in the field of infrared detector. The optical multiplexing structure is the key factor of IR mixed gas detection system, which consists of single light source multi-plexing detection structure and multi light source multiplexing detection structure. Particularly, single light source multiplexing detection structure is advantages of small volume and high integration, which make it a plausible candidate for the portable mixed gas detection system; Meanwhile, multi light source multiplexing detection structure is embodiment of time division multiplex, frequency division multiplexing and wavelength division multiplexing, and become the leading structure of the mixed gas detection system because of its wider spectral range, higher spectral resolution, etc. The detection method applied to IR mixed gas detection includes non-dispersive infrared (NDIR) spectroscopy, wavelength and frequency-modulation spectroscopy, cavity-enhanced spectroscopy and photoacoustic spectroscopy, etc. The IR mixed gas detection system designed by researchers after recognizing the whole sections of the proposed system, which play a significant role in industrial and agricultural production, environmental monitoring, and life science, etc.

  5. Large-Scale High-Resolution Cylinder Wake Measurements in a Wind Tunnel using Tomographic PIV with sCMOS Cameras

    NASA Astrophysics Data System (ADS)

    Michaelis, Dirk; Schroeder, Andreas

    2012-11-01

    Tomographic PIV has triggered vivid activity, reflected in a large number of publications, covering both: development of the technique and a wide range of fluid dynamic experiments. Maturing of tomo PIV allows the application in medium to large scale wind tunnels. Limiting factor for wind tunnel application is the small size of the measurement volume, being typically about of 50 × 50 × 15 mm3. Aim of this study is the optimization towards large measurement volumes and high spatial resolution performing cylinder wake measurements in a 1 meter wind tunnel. Main limiting factors for the volume size are the laser power and the camera sensitivity. So, a high power laser with 800 mJ per pulse is used together with low noise sCMOS cameras, mounted in forward scattering direction to gain intensity due to the Mie scattering characteristics. A mirror is used to bounce the light back, to have all cameras in forward scattering. Achievable particle density is growing with number of cameras, so eight cameras are used for a high spatial resolution. Optimizations lead to volume size of 230 × 200 × 52 mm3 = 2392 cm3, more than 60 times larger than previously. 281 × 323 × 68 vectors are calculated with spacing of 0.76 mm. The achieved measurement volume size and spatial resolution is regarded as a major step forward in the application of tomo PIV in wind tunnels. Supported by EU-project: no. 265695.

  6. Hematological indices of injury to lightly oiled birds from the Deepwater Horizon oil spill

    USGS Publications Warehouse

    Fallon, Jesse A.; Smith, Eric P.; Schoch, Nina; Paruk, James D.; Adams, Evan A.; Evers, David C.; Jodice, Patrick G. R.; Perkins, Christopher; Schulte, Shiloh A.; Hopkins, William A.

    2018-01-01

    Avian mortality events are common following large‐scale oil spills. However, the sublethal effects of oil on birds exposed to light external oiling are not clearly understood. We found that American oystercatchers (area of potential impact n = 42, reference n = 21), black skimmers (area of potential impact n = 121, reference n = 88), brown pelicans (area of potential impact n = 91, reference n = 48), and great egrets (area of potential impact n = 57, reference n = 47) captured between 20 June 2010 and 23 February 2011 following the Deepwater Horizon oil spill experienced oxidative injury to erythrocytes, had decreased volume of circulating erythrocytes, and showed evidence of a regenerative hematological response in the form of increased reticulocytes compared with reference populations. Erythrocytic inclusions consistent with Heinz bodies were present almost exclusively in birds from sites impacted with oil, a finding pathognomonic for oxidative injury to erythrocytes. Average packed cell volumes were 4 to 19% lower and average reticulocyte counts were 27 to 40% higher in birds with visible external oil than birds from reference sites. These findings provide evidence that small amounts of external oil exposure are associated with hemolytic anemia. Furthermore, we found that some birds captured from the area impacted by the spill but with no visible oiling also had erythrocytic inclusion bodies, increased reticulocytes, and reduced packed cell volumes when compared with birds from reference sites. Thus, birds suffered hematologic injury despite no visible oil at the time of capture. Together, these findings suggest that adverse effects of oil spills on birds may be more widespread than estimates based on avian mortality or severe visible oiling.

  7. Measurement of Aluminum Content In Reflector Materials For The PICO Dark Matter Detector

    NASA Astrophysics Data System (ADS)

    Borsodi, Haley; PICO Collaboration

    2015-04-01

    The PICO collaboration uses a bubble chamber technique to search for dark matter particles. Bubbles are registered with cameras, pressure sensors and acoustic transducers. To increase the visual contrast between bubbles and liquid, retro-reflectors are used to diffuse light from LEDs evenly throughout the inner chamber. One must, however, be careful that reflector materials not contribute radioactive background. Light nuclei, such as aluminum, can absorb alpha particles from radioactive contaminants and produce high energy neutron background in the inner volume of the chamber. Since aluminum oxides are a common reflector material and since commercial compositions are trade secrets, we had to demonstrate that the amounts of aluminum in the reflectors was small enough to allow them to be used in the chambers. After acid digesting candidate material strips, they were analyzed using Microwave Plasma Atomic Emission Spectroscopy. All of the proposed materials were found to have less than 1% Aluminum content (by mass), making them safe for use by the experiment. Indiana University South Bend.

  8. Plasmonic photonic crystals realized through DNA-programmable assembly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, Daniel J.; Zhang, Chuan; Ku, Jessie C.

    Three-dimensional dielectric photonic crystals have well-established enhanced light-matter interactions via high Q factors. Their plasmonic counterparts based on arrays of nanoparticles, however, have not been experimentally well explored owing to a lack of available synthetic routes for preparing them. However, such structures should facilitate these interactions based on the small mode volumes associated with plasmonic polarization. Herein we report strong light-plasmon interactions within 3D plasmonic photonic crystals that have lattice constants and nanoparticle diameters that can be independently controlled in the deep subwavelength size regime by using a DNA-programmable assembly technique. The strong coupling within such crystals is probed withmore » backscattering spectra, and the mode splitting (0.10 and 0.24 eV) is defined based on dispersion diagrams. Numerical simulations predict that the crystal photonic modes (Fabry-Perot modes) can be enhanced by coating the crystals with a silver layer, achieving moderate Q factors (~102) over the visible and near-infrared spectrum.« less

  9. Plasmonic photonic crystals realized through DNA-programmable assembly

    DOE PAGES

    Park, Daniel J.; Zhang, Chuan; Ku, Jessie C.; ...

    2014-12-29

    Three-dimensional dielectric photonic crystals have well-established enhanced light-matter interactions via high Q factors. Their plasmonic counterparts based on arrays of nanoparticles, however, have not been experimentally well explored owing to a lack of available synthetic routes for preparing them. However, such structures should facilitate these interactions based on the small mode volumes associated with plasmonic polarization. Herein we report strong light-plasmon interactions within 3D plasmonic photonic crystals that have lattice constants and nanoparticle diameters that can be independently controlled in the deep subwavelength size regime by using a DNA-programmable assembly technique. The strong coupling within such crystals is probed withmore » backscattering spectra, and the mode splitting (0.10 and 0.24 eV) is defined based on dispersion diagrams. Numerical simulations predict that the crystal photonic modes (Fabry-Perot modes) can be enhanced by coating the crystals with a silver layer, achieving moderate Q factors (~102) over the visible and near-infrared spectrum.« less

  10. Plasmonic photonic crystals realized through DNA-programmable assembly.

    PubMed

    Park, Daniel J; Zhang, Chuan; Ku, Jessie C; Zhou, Yu; Schatz, George C; Mirkin, Chad A

    2015-01-27

    Three-dimensional dielectric photonic crystals have well-established enhanced light-matter interactions via high Q factors. Their plasmonic counterparts based on arrays of nanoparticles, however, have not been experimentally well explored owing to a lack of available synthetic routes for preparing them. However, such structures should facilitate these interactions based on the small mode volumes associated with plasmonic polarization. Herein we report strong light-plasmon interactions within 3D plasmonic photonic crystals that have lattice constants and nanoparticle diameters that can be independently controlled in the deep subwavelength size regime by using a DNA-programmable assembly technique. The strong coupling within such crystals is probed with backscattering spectra, and the mode splitting (0.10 and 0.24 eV) is defined based on dispersion diagrams. Numerical simulations predict that the crystal photonic modes (Fabry-Perot modes) can be enhanced by coating the crystals with a silver layer, achieving moderate Q factors (∼10(2)) over the visible and near-infrared spectrum.

  11. Ultracompact Pseudowedge Plasmonic Lasers and Laser Arrays.

    PubMed

    Chou, Yu-Hsun; Hong, Kuo-Bin; Chang, Chun-Tse; Chang, Tsu-Chi; Huang, Zhen-Ting; Cheng, Pi-Ju; Yang, Jhen-Hong; Lin, Meng-Hsien; Lin, Tzy-Rong; Chen, Kuo-Ping; Gwo, Shangjr; Lu, Tien-Chang

    2018-02-14

    Concentrating light at the deep subwavelength scale by utilizing plasmonic effects has been reported in various optoelectronic devices with intriguing phenomena and functionality. Plasmonic waveguides with a planar structure exhibit a two-dimensional degree of freedom for the surface plasmon; the degree of freedom can be further reduced by utilizing metallic nanostructures or nanoparticles for surface plasmon resonance. Reduction leads to different lightwave confinement capabilities, which can be utilized to construct plasmonic nanolaser cavities. However, most theoretical and experimental research efforts have focused on planar surface plasmon polariton (SPP) nanolasers. In this study, we combined nanometallic structures intersecting with ZnO nanowires and realized the first laser emission based on pseudowedge SPP waveguides. Relative to current plasmonic nanolasers, the pseudowedge plasmonic lasers reported in our study exhibit extremely small mode volumes, high group indices, high spontaneous emission factors, and high Purell factors beneficial for the strong interaction between light and matter. Furthermore, we demonstrated that compact plasmonic laser arrays can be constructed, which could benefit integrated plasmonic circuits.

  12. Satellite Observations of Antarctic Sea Ice Thickness and Volume

    NASA Technical Reports Server (NTRS)

    Kurtz, Nathan; Markus, Thorsten

    2012-01-01

    We utilize satellite laser altimetry data from ICESat combined with passive microwave measurements to analyze basin-wide changes in Antarctic sea ice thickness and volume over a 5 year period from 2003-2008. Sea ice thickness exhibits a small negative trend while area increases in the summer and fall balanced losses in thickness leading to small overall volume changes. Using a five year time-series, we show that only small ice thickness changes of less than -0.03 m/yr and volume changes of -266 cu km/yr and 160 cu km/yr occurred for the spring and summer periods, respectively. The calculated thickness and volume trends are small compared to the observational time period and interannual variability which masks the determination of long-term trend or cyclical variability in the sea ice cover. These results are in stark contrast to the much greater observed losses in Arctic sea ice volume and illustrate the different hemispheric changes of the polar sea ice covers in recent years.

  13. Apparatus and method for collection and concentration of respirable particles into a small fluid volume

    DOEpatents

    Simon, Jonathan N.; Brown, Steve B.

    2002-01-01

    An apparatus and method for the collection of respirable particles and concentration of such particles into a small fluid volume. The apparatus captures and concentrates small (1-10 .mu.m) respirable particles into a sub-millileter volume of fluid. The method involves a two step operation, collection and concentration: wherein collection of particles is by a wetted surface having small vertical slits that act as capillary channels; and concentration is carried out by transfer of the collected particles to a small volume (sub-milliliter) container by centrifugal force whereby the particles are forced through the vertical slits and contact a non-wetted wall surface, and are deflected to the bottom where they are contained for analysis, such as a portable flow cytometer or a portable PCR DNA analysis system.

  14. Probing Gap Plasmons Down to Subnanometer Scales Using Collapsible Nanofingers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Song, Boxiang; Yao, Yuhan; Groenewald, Roelof E.

    Gap plasmonic nanostructures are of great interest due to their ability to concentrate light into small volumes. Theoretical studies, considering quantum mechanical effects, have predicted the optimal spatial gap between adjacent nanoparticles to be in the subnanometer regime in order to achieve the strongest possible field enhancement. In this paper, we present a technology to fabricate gap plasmonic structures with subnanometer resolution, high reliability, and high throughput using collapsible nanofingers. This approach enables us to systematically investigate the effects of gap size and tunneling barrier height. Finally, the experimental results are consistent with previous findings as well as with amore » straightforward theoretical model that is presented here.« less

  15. Probing Gap Plasmons Down to Subnanometer Scales Using Collapsible Nanofingers

    DOE PAGES

    Song, Boxiang; Yao, Yuhan; Groenewald, Roelof E.; ...

    2017-06-09

    Gap plasmonic nanostructures are of great interest due to their ability to concentrate light into small volumes. Theoretical studies, considering quantum mechanical effects, have predicted the optimal spatial gap between adjacent nanoparticles to be in the subnanometer regime in order to achieve the strongest possible field enhancement. In this paper, we present a technology to fabricate gap plasmonic structures with subnanometer resolution, high reliability, and high throughput using collapsible nanofingers. This approach enables us to systematically investigate the effects of gap size and tunneling barrier height. Finally, the experimental results are consistent with previous findings as well as with amore » straightforward theoretical model that is presented here.« less

  16. Testing and simulation of silicon photomultiplier readouts for scintillators in high-energy astronomy and solar physics

    NASA Astrophysics Data System (ADS)

    Bloser, P. F.; Legere, J. S.; Bancroft, C. M.; Jablonski, L. F.; Wurtz, J. R.; Ertley, C. D.; McConnell, M. L.; Ryan, J. M.

    2014-11-01

    Space-based gamma-ray detectors for high-energy astronomy and solar physics face severe constraints on mass, volume, and power, and must endure harsh launch conditions and operating environments. Historically, such instruments have usually been based on scintillator materials due to their relatively low cost, inherent ruggedness, high stopping power, and radiation hardness. New scintillator materials, such as LaBr3:Ce, feature improved energy and timing performance, making them attractive for future astronomy and solar physics space missions in an era of tightly constrained budgets. Despite this promise, the use of scintillators in space remains constrained by the volume, mass, power, and fragility of the associated light readout device, typically a vacuum photomultiplier tube (PMT). In recent years, silicon photomultipliers (SiPMs) have emerged as promising alternative light readout devices that offer gains and quantum efficiencies similar to those of PMTs, but with greatly reduced mass and volume, high ruggedness, low voltage requirements, and no sensitivity to magnetic fields. In order for SiPMs to replace PMTs in space-based instruments, however, it must be shown that they can provide comparable performance, and that their inherent temperature sensitivity can be corrected for. To this end, we have performed extensive testing and modeling of a small gamma-ray spectrometer composed of a 6 mm×6 mm SiPM coupled to a 6 mm×6 mm ×10 mm LaBr3:Ce crystal. A custom readout board monitors the temperature and adjusts the bias voltage to compensate for gain variations. We record an energy resolution of 5.7% (FWHM) at 662 keV at room temperature. We have also performed simulations of the scintillation process and optical light collection using Geant4, and of the SiPM response using the GosSiP package. The simulated energy resolution is in good agreement with the data from 22 keV to 662 keV. Above ~1 MeV, however, the measured energy resolution is systematically worse than the simulations. This discrepancy is likely due to the high input impedance of the readout board front-end electronics, which introduces a non-linear saturation effect in the SiPM for large light pulses. Analysis of the simulations indicates several additional steps that must be taken to optimize the energy resolution of SiPM-based scintillator detectors.

  17. Considerations on the calibration of small thermoluminescent dosimeters used for measurement of beta particle absorbed doses in liquid environments.

    PubMed

    Demidecki, A J; Williams, L E; Wong, J Y; Wessels, B W; Yorke, E D; Strandh, M; Strand, S E

    1993-01-01

    An investigation has been carried out on the factors which affect the absolute calibration of thermoluminescent dosimeters (TLDs) used in beta particle absorbed dose evaluations. Four effects on light output (LO) were considered: decay of detector sensitivity with time, finite TLD volume, dose linearity, and energy dependence. Most important of these was the decay of LO with time in culture medium, muscle tissue, and gels. This permanent loss of sensitivity was as large as an order of magnitude over a 21-day interval for the nominally 20-microns-thick disc-shaped CaSO4(Dy) TLDs in gel. Associated leaching of the dosimeter crystals out of the Teflon matrix was observed using scanning electron microscopy. Large channels leading from the outside environment into the TLDs were identified using SEM images. A possibility of batch dependence of fading was indicated. The second most important effect was the apparent reduction of light output due to finite size and increased specific gravity of the dosimeter (volume effect). We estimated this term by calculations as 10% in standard "mini" rods for beta particles from 90Y, but nearly a factor of 3 for 131I beta particles in the same geometry. No significant nonlinearity of the log (light output) with log (absorbed dose) over the range 0.05-20.00 Gy was discovered. Energy dependence of the LO was found to be not detectable, within measurement errors, over the range of 0.60-6.0 MeV mean energy electrons. With careful understanding of these effects, calibration via gel phantom would appear to be an acceptable strategy for mini TLDs used in beta absorbed dose evaluations in media.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Transformation kinetics for the shock wave induced phase transition in cadmium sulfide crystals

    NASA Astrophysics Data System (ADS)

    Knudson, M. D.; Gupta, Y. M.

    2002-06-01

    Initial stage kinetics of the cadmium sulfide (CdS) phase transition was investigated using picosecond time-resolved electronic spectroscopy in plate-impact shock wave experiments. Real-time changes in the electronic spectra were observed, with 100 ps time resolution, in CdS single crystals shocked along a and c axes to stresses ranging between 35 and 90 kbar, which is above the phase-transition threshold stress of approximately 30 kbar. Significant difference in the transformation kinetics was observed for the two crystal orientations. At sufficiently high instantaneous stress, above approximately 60 to 70 kbar for a axis and 50 kbar for c axis, transformation to a metastable state appears to reach a constant state within the 100 ps time resolution. At lower instantaneous stresses, an incubation period on the order of several nanoseconds is observed prior to the onset of electronic changes that mark the onset of the structural change. The subsequent increase in absorbance was quite rapid, with a constant state being reached within the first few nanoseconds after the onset of the structural changes. These results suggest that the nucleation process determines the transformation rate. This insight into transformation kinetics, along with the transformation mechanism obtained from the high-stress experiments, was used to develop a phenomenological model, incorporating ideas of nucleation and growth in martensitic transformations, to simulate the time-dependent extinction of light observed in our experiments. The calculational results incorporating both extinction due to light absorption by the daughter phase volumes and scattering of light by small volumes of the daughter phase were in good agreement with experimental observations. Finally, the orientational differences observed in the transformation kinetics were interpreted in terms of the differences in the elastic-plastic response for the two orientations.

  19. Fabrication and Characterization of Surrogate Fuel Particles Using the Spark Erosion Method

    NASA Astrophysics Data System (ADS)

    Metzger, Kathryn E.

    In light of the disaster at the Fukushima Daiichi Nuclear Plant, the Department of Energy's Advanced Fuels Program has shifted its interest from enhanced performance fuels to enhanced accident tolerance fuels. Dispersion fuels possess higher thermal conductivities than traditional light water reactor fuel and as a result, offer improved safety margins. The benefits of a dispersion fuel are due to the presence of the secondary non-fissile phase (matrix), which serves as a barrier to fission products and improves the overall thermal performance of the fuel. However, the presence of a matrix material reduces the fuel volume, which lowers the fissile content of dispersion. This issue can be remedied through the development of higher density fuel phases or through an optimization of fuel particle size and volume loading. The latter requirement necessitates the development of fabrication methods to produce small, micron-order fuel particles. This research examines the capabilities of the spark erosion process to fabricate particles on the order of 10 μm. A custom-built spark erosion device by CT Electromechanica was used to produce stainless steel surrogate fuel particles in a deionized water dielectric. Three arc intensities were evaluated to determine the effect on particle size. Particles were filtered from the dielectric using a polycarbonate membrane filter and vacuum filtration system. Fabricated particles were characterized via field emission scanning electron microscopy (FESEM), laser light particle size analysis, energy-dispersive spectroscopy (EDS), X-ray diffraction analysis (XRD), and gas pycnometry. FESEM images reveal that the spark erosion process produces highly spherical particles on the order of 10 microns. These findings are substantiated by the results of particle size analysis. Additionally, EDS and XRD results indicate the presence of oxide phases, which suggests the dielectric reacted with the molten debris during particle formation.

  20. Bioluminescence of Marine Dinoflagellates

    PubMed Central

    Seliger, H. H.; Fastie, W. G.; Taylor, W. R.; McElroy, W. D.

    1962-01-01

    Portable light-baffled underwater photometers have been designed for the measurement of dinoflagellate bioluminescence by day and night. Maximal light emission is obtained by mechanical stimulation in a defined volume. The pump which stimulates the dinoflagellates also constantly replenishes the sample volume so that continuous measurements are possible. Evidence for both diurnal variation and vertical migration is presented. Using luminous bacteria for calibration a single dinoflagellate has been found to emit of the order of 1010 light quanta per flash. The technique suggests that large scale mapping of bioluminescence is feasible. PMID:19873546

  1. Exposure Render: An Interactive Photo-Realistic Volume Rendering Framework

    PubMed Central

    Kroes, Thomas; Post, Frits H.; Botha, Charl P.

    2012-01-01

    The field of volume visualization has undergone rapid development during the past years, both due to advances in suitable computing hardware and due to the increasing availability of large volume datasets. Recent work has focused on increasing the visual realism in Direct Volume Rendering (DVR) by integrating a number of visually plausible but often effect-specific rendering techniques, for instance modeling of light occlusion and depth of field. Besides yielding more attractive renderings, especially the more realistic lighting has a positive effect on perceptual tasks. Although these new rendering techniques yield impressive results, they exhibit limitations in terms of their exibility and their performance. Monte Carlo ray tracing (MCRT), coupled with physically based light transport, is the de-facto standard for synthesizing highly realistic images in the graphics domain, although usually not from volumetric data. Due to the stochastic sampling of MCRT algorithms, numerous effects can be achieved in a relatively straight-forward fashion. For this reason, we have developed a practical framework that applies MCRT techniques also to direct volume rendering (DVR). With this work, we demonstrate that a host of realistic effects, including physically based lighting, can be simulated in a generic and flexible fashion, leading to interactive DVR with improved realism. In the hope that this improved approach to DVR will see more use in practice, we have made available our framework under a permissive open source license. PMID:22768292

  2. Parsing partial molar volumes of small molecules: a molecular dynamics study.

    PubMed

    Patel, Nisha; Dubins, David N; Pomès, Régis; Chalikian, Tigran V

    2011-04-28

    We used molecular dynamics (MD) simulations in conjunction with the Kirkwood-Buff theory to compute the partial molar volumes for a number of small solutes of various chemical natures. We repeated our computations using modified pair potentials, first, in the absence of the Coulombic term and, second, in the absence of the Coulombic and the attractive Lennard-Jones terms. Comparison of our results with experimental data and the volumetric results of Monte Carlo simulation with hard sphere potentials and scaled particle theory-based computations led us to conclude that, for small solutes, the partial molar volume computed with the Lennard-Jones potential in the absence of the Coulombic term nearly coincides with the cavity volume. On the other hand, MD simulations carried out with the pair interaction potentials containing only the repulsive Lennard-Jones term produce unrealistically large partial molar volumes of solutes that are close to their excluded volumes. Our simulation results are in good agreement with the reported schemes for parsing partial molar volume data on small solutes. In particular, our determined interaction volumes() and the thickness of the thermal volume for individual compounds are in good agreement with empirical estimates. This work is the first computational study that supports and lends credence to the practical algorithms of parsing partial molar volume data that are currently in use for molecular interpretations of volumetric data.

  3. Comparison between Hydrogen, Methane and Ethylene Fuels in a 3-D Scramjet at Mach 8

    DTIC Science & Technology

    2016-06-24

    characteristics in air. The disadvantage of hydrogen is its low density, which is a particular problem for small vehicles with significant internal...characteristics in air. The disadvantage of hydrogen is its low density, which is a particular problem for small vehicles with significant internal volume...The low energy per unit volume of gaseous hydrogen, however, is a significant problem for small vehicles with internal volume constraints, in addition

  4. Brain tissue volumes in the general elderly population. The Rotterdam Scan Study.

    PubMed

    Ikram, M Arfan; Vrooman, Henri A; Vernooij, Meike W; van der Lijn, Fedde; Hofman, Albert; van der Lugt, Aad; Niessen, Wiro J; Breteler, Monique M B

    2008-06-01

    We investigated how volumes of cerebrospinal fluid (CSF), grey matter (GM) and white matter (WM) varied with age, sex, small vessel disease and cardiovascular risk factors in the Rotterdam Scan Study. Participants (n=490; 60-90 years) were non-demented and 51.0% had hypertension, 4.9% had diabetes mellitus, 17.8% were current smoker and 54.0% were former smoker. We segmented brain MR-images into GM, normal WM, white matter lesion (WML) and CSF. Brain infarcts were rated visually. Volumes were expressed as percentage of intra-cranial volume. With increasing age, volumes of total brain, normal WM and total WM decreased; that of GM remained unchanged; and that of WML increased, in both men and women. Excluding persons with infarcts did not alter these results. Persons with larger load of small vessel disease had smaller brain volume, especially normal WM volume. Diastolic blood pressure, diabetes mellitus and current smoking were also related to smaller brain volume. In the elderly, higher age, small vessel disease and cardiovascular risk factors are associated with smaller brain volume, especially WM volume.

  5. LED roadway lighting, volume 2 : field evaluations and software comparisons.

    DOT National Transportation Integrated Search

    2012-10-01

    The use of light-emitting diodes (LEDs) for roadway lighting can potentially save energy costs and reduce the frequency of maintenance. The objective of this study is to explore the current state of the art in LED roadway lighting technology. Three s...

  6. Design and optimization of a volume-phase holographic grating for simultaneous use with red, green, and blue light using unpolarized light.

    PubMed

    Mahamat, Adoum H; Narducci, Frank A; Schwiegerling, James

    2016-03-01

    Volume-phase holographic (VPH) gratings have been designed for use in many areas of science and technology, such as optical communication, optical imaging, and astronomy. In this paper, the design of a volume-phase holographic grating, simultaneously optimized to operate in the red, green, and blue wavelengths, is presented along with a study of its fabrication tolerances. The grating is optimized to produce 98% efficiency at λ=532  nm and at least 75% efficiency in the region between 400 and 700 nm, when the incident light is unpolarized. The optimization is done for recording in dichromated gelatin with a thickness of 12 μm, an average refractive index of 1.5, and a refractive index modulation of 0.022.

  7. Bright Ideas for Measuring Light.

    ERIC Educational Resources Information Center

    Amend, John R.; Schuler, John A.

    1983-01-01

    Describes an inexpensive device (around $8.00) for measuring light. The circuit used includes five resistors, three small capacitors, a cadmium sulfide light sensor, two integrated circuits, and two light-emitting diodes. The unit is constructed on a small perforated circuit board and powered by a 9-V transistor radio battery. (JN)

  8. Shape-Memory Hydrogels: Evolution of Structural Principles To Enable Shape Switching of Hydrophilic Polymer Networks.

    PubMed

    Löwenberg, Candy; Balk, Maria; Wischke, Christian; Behl, Marc; Lendlein, Andreas

    2017-04-18

    The ability of hydrophilic chain segments in polymer networks to strongly interact with water allows the volumetric expansion of the material and formation of a hydrogel. When polymer chain segments undergo reversible hydration depending on environmental conditions, smart hydrogels can be realized, which are able to shrink/swell and thus alter their volume on demand. In contrast, implementing the capacity of hydrogels to switch their shape rather than volume demands more sophisticated chemical approaches and structural concepts. In this Account, the principles of hydrogel network design, incorporation of molecular switches, and hydrogel microstructures are summarized that enable a spatially directed actuation of hydrogels by a shape-memory effect (SME) without major volume alteration. The SME involves an elastic deformation (programming) of samples, which are temporarily fixed by reversible covalent or physical cross-links resulting in a temporary shape. The material can reverse to the original shape when these molecular switches are affected by application of a suitable stimulus. Hydrophobic shape-memory polymers (SMPs), which are established with complex functions including multiple or reversible shape-switching, may provide inspiration for the molecular architecture of shape-memory hydrogels (SMHs), but cannot be identically copied in the world of hydrophilic soft materials. For instance, fixation of the temporary shape requires cross-links to be formed also in an aqueous environment, which may not be realized, for example, by crystalline domains from the hydrophilic main chains as these may dissolve in presence of water. Accordingly, dual-shape hydrogels have evolved, where, for example, hydrophobic crystallizable side chains have been linked into hydrophilic polymer networks to act as temperature-sensitive temporary cross-links. By incorporating a second type of such side chains, triple-shape hydrogels can be realized. Considering the typically given light permeability of hydrogels and the fully hydrated state with easy permeation by small molecules, other types of stimuli like light, pH, or ions can be employed that may not be easily used in hydrophobic SMPs. In some cases, those molecular switches can respond to more than one stimulus, thus increasing the number of opportunities to induce actuation of these synthetic hydrogels. Beyond this, biopolymer-based hydrogels can be equipped with a shape switching function when facilitating, for example, triple helix formation in proteins or ionic interactions in polysaccharides. Eventually, microstructured SMHs such as hybrid or porous structures can combine the shape-switching function with an improved performance by helping to overcome frequent shortcomings of hydrogels such as low mechanical strength or volume change upon temporary cross-link cleavage. Specifically, shape switching without major volume alteration is possible in porous SMHs by decoupling small volume changes of pore walls on the microscale and the macroscopic sample size. Furthermore, oligomeric rather than short aliphatic side chains as molecular switches allow stabilization of the sample volumes. Based on those structural principles and switching functionalities, SMHs have already entered into applications as soft actuators and are considered, for example, for cell manipulation in biomedicine. In the context of those applications, switching kinetics, switching forces, and reversibility of switching are aspects to be further explored.

  9. Airborne chemistry: acoustic levitation in chemical analysis.

    PubMed

    Santesson, Sabina; Nilsson, Staffan

    2004-04-01

    This review with 60 references describes a unique path to miniaturisation, that is, the use of acoustic levitation in analytical and bioanalytical chemistry applications. Levitation of small volumes of sample by means of a levitation technique can be used as a way to avoid solid walls around the sample, thus circumventing the main problem of miniaturisation, the unfavourable surface-to-volume ratio. Different techniques for sample levitation have been developed and improved. Of the levitation techniques described, acoustic or ultrasonic levitation fulfils all requirements for analytical chemistry applications. This technique has previously been used to study properties of molten materials and the equilibrium shape()and stability of liquid drops. Temperature and mass transfer in levitated drops have also been described, as have crystallisation and microgravity applications. The airborne analytical system described here is equipped with different and exchangeable remote detection systems. The levitated drops are normally in the 100 nL-2 microL volume range and additions to the levitated drop can be made in the pL-volume range. The use of levitated drops in analytical and bioanalytical chemistry offers several benefits. Several remote detection systems are compatible with acoustic levitation, including fluorescence imaging detection, right angle light scattering, Raman spectroscopy, and X-ray diffraction. Applications include liquid/liquid extractions, solvent exchange, analyte enrichment, single-cell analysis, cell-cell communication studies, precipitation screening of proteins to establish nucleation conditions, and crystallisation of proteins and pharmaceuticals.

  10. Efficient Stochastic Rendering of Static and Animated Volumes Using Visibility Sweeps.

    PubMed

    von Radziewsky, Philipp; Kroes, Thomas; Eisemann, Martin; Eisemann, Elmar

    2017-09-01

    Stochastically solving the rendering integral (particularly visibility) is the de-facto standard for physically-based light transport but it is computationally expensive, especially when displaying heterogeneous volumetric data. In this work, we present efficient techniques to speed-up the rendering process via a novel visibility-estimation method in concert with an unbiased importance sampling (involving environmental lighting and visibility inside the volume), filtering, and update techniques for both static and animated scenes. Our major contributions include a progressive estimate of partial occlusions based on a fast sweeping-plane algorithm. These occlusions are stored in an octahedral representation, which can be conveniently transformed into a quadtree-based hierarchy suited for a joint importance sampling. Further, we propose sweep-space filtering, which suppresses the occurrence of fireflies and investigate different update schemes for animated scenes. Our technique is unbiased, requires little precomputation, is highly parallelizable, and is applicable to a various volume data sets, dynamic transfer functions, animated volumes and changing environmental lighting.

  11. Laser-based volumetric flow visualization by digital color imaging of a spectrally coded volume.

    PubMed

    McGregor, T J; Spence, D J; Coutts, D W

    2008-01-01

    We present the framework for volumetric laser-based flow visualization instrumentation using a spectrally coded volume to achieve three-component three-dimensional particle velocimetry. By delivering light from a frequency doubled Nd:YAG laser with an optical fiber, we exploit stimulated Raman scattering within the fiber to generate a continuum spanning the visible spectrum from 500 to 850 nm. We shape and disperse the continuum light to illuminate a measurement volume of 20 x 10 x 4 mm(3), in which light sheets of differing spectral properties overlap to form an unambiguous color variation along the depth direction. Using a digital color camera we obtain images of particle fields in this volume. We extract the full spatial distribution of particles with depth inferred from particle color. This paper provides a proof of principle of this instrument, examining the spatial distribution of a static field and a spray field of water droplets ejected by the nozzle of an airbrush.

  12. Design, simulation, and optimization of an RGB polarization independent transmission volume hologram

    NASA Astrophysics Data System (ADS)

    Mahamat, Adoum Hassan

    Volume phase holographic (VPH) gratings have been designed for use in many areas of science and technology such as optical communication, medical imaging, spectroscopy and astronomy. The goal of this dissertation is to design a volume phase holographic grating that provides diffraction efficiencies of at least 70% for the entire visible wavelengths and higher than 90% for red, green, and blue light when the incident light is unpolarized. First, the complete design, simulation and optimization of the volume hologram are presented. The optimization is done using a Monte Carlo analysis to solve for the index modulation needed to provide higher diffraction efficiencies. The solutions are determined by solving the diffraction efficiency equations determined by Kogelnik's two wave coupled-wave theory. The hologram is further optimized using the rigorous coupled-wave analysis to correct for effects of absorption omitted by Kogelnik's method. Second, the fabrication or recording process of the volume hologram is described in detail. The active region of the volume hologram is created by interference of two coherent beams within the thin film. Third, the experimental set up and measurement of some properties including the diffraction efficiencies of the volume hologram, and the thickness of the active region are conducted. Fourth, the polarimetric response of the volume hologram is investigated. The polarization study is developed to provide insight into the effect of the refractive index modulation onto the polarization state and diffraction efficiency of incident light.

  13. Small Power Systems Solar Electric Workshop Proceedings. Volume 1: Executive report. Volume 2: Invited papers

    NASA Technical Reports Server (NTRS)

    Ferber, R. (Editor); Evans, D. (Editor)

    1978-01-01

    The background, objectives and methodology used for the Small Power Systems Solar Electric Workshop are described, and a summary of the results and conclusions developed at the workshop regarding small solar thermal electric power systems is presented.

  14. All-optical photochromic spatial light modulators based on photoinduced electron transfer in rigid matrices

    NASA Technical Reports Server (NTRS)

    Beratan, David N. (Inventor); Perry, Joseph W. (Inventor)

    1991-01-01

    A single material (not a multi-element structure) spatial light modulator may be written to, as well as read out from, using light. The device has tailorable rise and hold times dependent on the composition and concentration of the molecular species used as the active components. The spatial resolution of this device is limited only by light diffraction as in volume holograms. The device may function as a two-dimensional mask (transmission or reflection) or as a three-dimensional volume holographic medium. This device, based on optically-induced electron transfer, is able to perform incoherent to coherent image conversion or wavelength conversion over a wide spectral range (ultraviolet, visible, or near-infrared regions).

  15. Deviation from Power Law Behavior in Landslide Phenomenon

    NASA Astrophysics Data System (ADS)

    Li, L.; Lan, H.; Wu, Y.

    2013-12-01

    Power law distribution of magnitude is widely observed in many natural hazards (e.g., earthquake, floods, tornadoes, and forest fires). Landslide is unique as the size distribution of landslide is characterized by a power law decrease with a rollover in the small size end. Yet, the emergence of the rollover, i.e., the deviation from power law behavior for small size landslides, remains a mystery. In this contribution, we grouped the forces applied on landslide bodies into two categories: 1) the forces proportional to the volume of failure mass (gravity and friction), and 2) the forces proportional to the area of failure surface (cohesion). Failure occurs when the forces proportional to volume exceed the forces proportional to surface area. As such, given a certain mechanical configuration, the failure volume to failure surface area ratio must exceed a corresponding threshold to guarantee a failure. Assuming all landslides share a uniform shape, which means the volume to surface area ratio of landslide regularly increase with the landslide volume, a cutoff of landslide volume distribution in the small size end can be defined. However, in realistic landslide phenomena, where heterogeneities of landslide shape and mechanical configuration are existent, a simple cutoff of landslide volume distribution does not exist. The stochasticity of landslide shape introduce a probability distribution of the volume to surface area ratio with regard to landslide volume, with which the probability that the volume to surface ratio exceed the threshold can be estimated regarding values of landslide volume. An experiment based on empirical data showed that this probability can induce the power law distribution of landslide volume roll down in the small size end. We therefore proposed that the constraints on the failure volume to failure surface area ratio together with the heterogeneity of landslide geometry and mechanical configuration attribute for the deviation from power law behavior in landslide phenomenon. Figure shows that a rollover of landslide size distribution in the small size end is produced as the probability for V/S (the failure volume to failure surface ratio of landslide) exceeding the mechanical threshold applied to the power law distribution of landslide volume.

  16. Using Mobile Device Samples to Estimate Traffic Volumes

    DOT National Transportation Integrated Search

    2017-12-01

    In this project, TTI worked with StreetLight Data to evaluate a beta version of its traffic volume estimates derived from global positioning system (GPS)-based mobile devices. TTI evaluated the accuracy of average annual daily traffic (AADT) volume :...

  17. Nonlinear Frequency Conversion in III-V Semiconductor Photonic Crystals

    DTIC Science & Technology

    2012-03-01

    nanocavities, by localizing light into sub-cubic optical wavelength volumes with long photon storage times, can greatly enhance the efficiency of...dissertation shows how optical nanocavities, by localizing light into sub-cubic optical wavelength volumes with long photon storage times, can greatly...8.2.3 Lithographic localization of molecules to cavity region . . . . . 86 8.2.4 Low temperature spectroscopy of DNQDI . . . . . . . . . . . 89 8.2.5

  18. 40 CFR 80.595 - How does a small or GPA refiner apply for a motor vehicle diesel fuel volume baseline for the...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... for a motor vehicle diesel fuel volume baseline for the purpose of extending their gasoline sulfur... a small or GPA refiner apply for a motor vehicle diesel fuel volume baseline for the purpose of... duration of the GPA standards under § 80.540 must apply for a motor vehicle diesel fuel volume baseline by...

  19. Cell volume and plasma membrane osmotic water permeability in epithelial cell layers measured by interferometry.

    PubMed

    Farinas, J; Verkman, A S

    1996-12-01

    The development of strategies to measure plasma membrane osmotic water permeability (Pf) in epithelial cells has been motivated by the identification of a family of molecular water channels. A general approach utilizing interferometry to measure cell shape and volume was developed and applied to measure Pf in cell layers. The method is based on the cell volume dependence of optical path length (OPL) for a light beam passing through the cell. The small changes in OPL were measured by interferometry. A mathematical model was developed to relate the interference signal to cell volume changes for cells of arbitrary shape and size. To validate the model, a Mach-Zehnder interference microscope was used to image OPL in an Madin Darby Canine Kidney (MDCK) cell layer and to reconstruct the three-dimensional cell shape (OPL resolution < lambda/25). As predicted by the model, a doubling of cell volume resulted in a change in OPL that was proportional to the difference in refractive indices between water and the extracellular medium. The time course of relative cell volume in response to an osmotic gradient was computed from serial interference images. To measure cell volume without microscopy and image analysis, a Mach-Zehnder interferometer was constructed in which one of two interfering laser beams passed through a flow chamber containing the cell layer. The interference signal in response to an osmotic gradient was analyzed to quantify the time course of relative cell volume. The calculated MDCK cell plasma membrane Pf of 6.1 x 10(-4) cm/s at 24 degrees C agreed with that obtained by interference microscopy and by a total internal reflection fluorescence method. Interferometry was also applied to measure the apical plasma membrane water permeability of intact toad urinary bladder; Pf increased fivefold after forskolin stimulation to 0.04 cm/s at 23 degrees C. These results establish and validate the application of interferometry to quantify cell volume and osmotic water permeability in cell layers.

  20. SU-G-JeP3-10: Update On a Real-Time Treatment Guidance System Using An IR Navigation System for Pleural PDT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, M; Penjweini, R; Zhu, T

    Purpose: Photodynamic therapy (PDT) is used in conjunction with surgical debulking of tumorous tissue during treatment for pleural mesothelioma. One of the key components of effective PDT is uniform light distribution. Currently, light is monitored with 8 isotropic light detectors that are placed at specific locations inside the pleural cavity. A tracking system with real-time feedback software can be utilized to improve the uniformity of light in addition to the existing detectors. Methods: An infrared (IR) tracking camera is used to monitor the movement of the light source. The same system determines the pleural geometry of the treatment area. Softwaremore » upgrades allow visualization of the pleural cavity as a two-dimensional volume. The treatment delivery wand was upgraded for ease of light delivery while incorporating the IR system. Isotropic detector locations are also displayed. Data from the tracking system is used to calculate the light fluence rate delivered. This data is also compared with in vivo data collected via the isotropic detectors. Furthermore, treatment volume information will be used to form light dose volume histograms of the pleural cavity. Results: In a phantom study, the light distribution was improved by using real-time guidance compared to the distribution when using detectors without guidance. With the tracking system, 2D data can be collected regarding light fluence rather than just the 8 discrete locations inside the pleural cavity. Light fluence distribution on the entire cavity can be calculated at every time in the treatment. Conclusion: The IR camera has been used successfully during pleural PDT patient treatment to track the motion of the light source and provide real-time display of 2D light fluence. It is possible to use the feedback system to deliver a more uniform dose of light throughout the pleural cavity.« less

  1. A novel device for quantitative measurement of chloride concentration by fluorescence indicator

    NASA Astrophysics Data System (ADS)

    Wang, Junsheng; Wu, Xudong; Chon, Chanhee; Gonska, Tanja; Li, Dongqing

    2012-02-01

    Cystic fibrosis (CF) is a life-threatening genetic disease. At present, the common method for diagnosis of CF is to detect the chloride concentration in sweat using ion-selective electrodes. However, the current sweat testing methods require a relatively large quantity of sweat sample, at least 25 µL, which is very difficult to obtain, especially for newborns. This paper presents a new method and a new device for rapid detection of the chloride concentration from a small volume of solution. In this method, the chloride concentration is determined quantitatively by the fluorescence intensity of MQAE, a chloride ion fluorescent indicator. In this device, the sample is carried by a small piece of filter paper on a cover glass exposed to an UV LED light source. The resulting fluorescent signals are detected by a Si photodiode. Data acquisition and processing are accomplished by LabVIEW software in a PDA. Based on the Stern-Volmer relationship, the effects of different parameters on the fluorescence intensity were analyzed. The observed significant difference between 40 and 60 mM (the borderline of chloride concentration for CF) is discussed in this paper. The results show that detection can be completed within 10 s. The minimum detectable volume of the chloride solution is 1 μL. The novel method and the device are of great potential for CF diagnosis.

  2. Structural development of redwood branches and its effects on wood growth.

    PubMed

    Kramer, Russell D; Sillett, Stephen C; Carroll, Allyson L

    2014-03-01

    Redwood branches provide all the carbohydrates for the most carbon-heavy forests on Earth, and recent whole-tree measurements have quantified trunk growth rates associated with complete branch inventories. Providing all of a tree's photosynthetic capacity, branches represent an increasing proportion of total aboveground wood production as trees enlarge. To examine branch development and its effects on wood volume growth, we dissected 31 branches from eight Sequoia sempervirens (D. Don) Endl. and seven Sequoiadendron giganteum Lindl. trees. The cambium-area-to-leaf-area ratio was maintained with size and age but increased with light availability, whereas the heartwood-deposition-area-to-leaf-area ratio increased with size and age but was insensitive to light availability. The proportion of foliage mass arrayed in <1-cm-diameter epicormic shoots increased with decreasing light and was higher in Sequoia (20-60%) than in Sequoiadendron (3-16%). Well-illuminated branches concentrated leaves higher and distally, while shaded branches distributed leaves lower and proximally. In similar light environments, older branches distributed leaves lower and more proximally than younger branches. Branch size, light, species, heartwood area, a heartwood-area-species interaction, and ovulate cone mass predicted 87.5% of the variability in wood volume growth of branches. After accounting for the positive effects of size and light, wood volume growth declined with heartwood area and age. The effect of age was trivial compared to the effect of heartwood area, suggesting that heartwood expansion caused the age-related decline in wood volume growth. Additionally, Sequoiadendron branches of similar size and light environment with more ovulate cones produced less wood, even though these cones were long-lived and photosynthetic, reflecting the energetic cost of seed production. These results contributed to a conceptual model of branch development in which light availability, injury, heartwood content, gravity, and time interact to produce the high degree of branch structural variation evident within redwood crowns.

  3. Deployable Propulsion and Power Systems for Solar System Exploration

    NASA Technical Reports Server (NTRS)

    Johnson, Les; Carr, John

    2017-01-01

    NASA is developing thin-film based, deployable propulsion, power and communication systems for small spacecraft that could provide a revolutionary new capability allowing small spacecraft exploration of the solar system. The Near Earth Asteroid (NEA) Scout reconnaissance mission will demonstrate solar sail propulsion on a 6U CubeSat interplanetary spacecraft and lay the groundwork for their future use in deep space science and exploration missions. Solar sails use sunlight to propel vehicles through space by reflecting solar photons from a large, mirror-like sail made of a lightweight, highly reflective material. This continuous photon pressure provides propellantless thrust, allowing for very high delta V maneuvers on long-duration, deep space exploration. Since reflected light produces thrust, solar sails require no onboard propellant. The Lightweight Integrated Solar Array and Transceiver (LISA-T) is a launch stowed, orbit deployed array on which thin-film photovoltaic and antenna elements are embedded. Inherently, small satellites are limited in surface area, volume, and mass allocation; driving competition between power, communications, and GN&C (guidance navigation and control) subsystems. This restricts payload capability and limits the value of these low-cost satellites. LISA-T is addressing this issue, deploying large-area arrays from a reduced volume and mass envelope - greatly enhancing power generation and communications capabilities of small spacecraft. The NEA Scout mission, funded by NASA's Advanced Exploration Systems Program and managed by NASA MSFC, will use the solar sail as its primary propulsion system, allowing it to survey and image one or more NEA's of interest for possible future human exploration. NEA Scout uses a 6U cubesat (to be provided by NASA's Jet Propulsion Laboratory), an 86 sq m solar sail and will weigh less than 12 kilograms. NEA Scout will be launched on the first flight of the Space Launch System in 2018. Similar in concept to the NEA Scout solar sail, the LISA-T array is designed to fit into a very small volume and provide abundant power and omnidirectional communications in just about any deployment configuration. The technology is being proposed for flight validation as early as 2019 in a low earth orbit demonstration using a 3U cubesat, of which less than 1U will be devoted to the LISA-T power and propulsion system. By leveraging recent advancements in thin films, photovoltaics and miniaturized electronics, new mission-level capabilities will be enabled aboard lower-cost small spacecraft instead of their more expensive, traditional counterparts, enabling a new generation of frequent, inexpensive deep space missions.

  4. Impact of Use of Smaller Volume, Smaller Vacuum Blood Collection Tubes on Hemolysis in Emergency Department Blood Samples.

    PubMed

    Phelan, Michael P; Reineks, Edmunds Z; Berriochoa, Jacob P; Schold, Jesse D; Hustey, Fredric M; Chamberlin, Janelle; Kovach, Annmarie

    2017-10-01

    Hemolyzed blood samples commonly occur in hospital emergency departments (EDs). Our objective was to determine whether replacing standard large-volume/high-vacuum sample tubes with low-volume/low-vacuum tubes would significantly affect ED hemolysis. This was a prospective intervention of the use of small-volume/vacuum collection tubes. We evaluated all potassium samples in ED patients and associated hemolysis. We used χ2 tests to compare hemolysis incidence prior to and following utilization of small tubes for chemistry collection. There were 35,481 blood samples collected during the study period. Following implementation of small-volume tubes, overall hemolysis decreased from a baseline of 11.8% to 2.9% (P < .001) with corresponding reductions in hemolysis with comment (8.95% vs 1.99%; P < .001) gross hemolysis (2.84% vs 0.90%; P < .007). This work demonstrates that significant improvements in ED hemolysis can be achieved by utilization of small-volume/vacuum sample collection tubes. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  5. High-resolution recording of particle tracks with in-line holography in a large cryogenic bubble chamber

    NASA Astrophysics Data System (ADS)

    Harigel, Gert G.

    2000-10-01

    Holography has been used successfully in combination with conventional optics for the first time in a large cryogenic bubble chamber, the 15-Foot Bubble Chamber at the Fermi National Accelerator Laboratory (FNAL), during a physics run in a high energy neutrino beam. The innovative system combined the reference beam with the object beam, irradiating a conical volume of approx1.5m3. Bubble tracks from neutrino interactions with a width of approx 120 micrometers have been recorded with good contrast. The ratio of intensities of the object light to the reference light striking the film is called the beam branching ratio (BBR). We obtained in our experiment an exceedingly small minimum- observable ration of BBR = (0.54 divided by 0.21) x 107. The technology has the potential for a wide range of applications. This paper describes the various difficulties in achieving the success. It required the development of laser pulse stretching via enhanced closed loop control with slow Q- switching, to overcome excessive heating of the cryogenic liquid by the powerful laser beam. A sophisticated system of light-absorbing baffles had to be installed to avoid stray light reaching the holographic film. Optical decoupling of classical and holographic illumination systems was required. Real and virtual image replay machines for holograms were built, tailored to our illumination technique.

  6. Light focusing through a multiple scattering medium: ab initio computer simulation

    NASA Astrophysics Data System (ADS)

    Danko, Oleksandr; Danko, Volodymyr; Kovalenko, Andrey

    2018-01-01

    The present study considers ab initio computer simulation of the light focusing through a complex scattering medium. The focusing is performed by shaping the incident light beam in order to obtain a small focused spot on the opposite side of the scattering layer. MSTM software (Auburn University) is used to simulate the propagation of an arbitrary monochromatic Gaussian beam and obtain 2D distribution of the optical field in the selected plane of the investigated volume. Based on the set of incident and scattered fields, the pair of right and left eigen bases and corresponding singular values were calculated. The pair of right and left eigen modes together with the corresponding singular value constitute the transmittance eigen channel of the disordered media. Thus, the scattering process is described in three steps: 1) initial field decomposition in the right eigen basis; 2) scaling of decomposition coefficients for the corresponding singular values; 3) assembling of the scattered field as the composition of the weighted left eigen modes. Basis fields are represented as a linear combination of the original Gaussian beams and scattered fields. It was demonstrated that 60 independent control channels provide focusing the light into a spot with the minimal radius of approximately 0.4 μm at half maximum. The intensity enhancement in the focal plane was equal to 68 that coincided with theoretical prediction.

  7. Light Emission Intensities of Luminescent Y2O3:Eu and Gd2O3:Eu Particles of Various Sizes

    PubMed Central

    Adam, Jens; Metzger, Wilhelm; Koch, Marcus; Rogin, Peter; Coenen, Toon; Atchison, Jennifer S.; König, Peter

    2017-01-01

    There is great technological interest in elucidating the effect of particle size on the luminescence efficiency of doped rare earth oxides. This study demonstrates unambiguously that there is a size effect and that it is not dependent on the calcination temperature. The Y2O3:Eu and Gd2O3:Eu particles used in this study were synthesized using wet chemistry to produce particles ranging in size between 7 nm and 326 nm and a commercially available phosphor. These particles were characterized using three excitation methods: UV light at 250 nm wavelength, electron beam at 10 kV, and X-rays generated at 100 kV. Regardless of the excitation source, it was found that with increasing particle diameter there is an increase in emitted light. Furthermore, dense particles emit more light than porous particles. These results can be explained by considering the larger surface area to volume ratio of the smallest particles and increased internal surface area of the pores found in the large particles. For the small particles, the additional surface area hosts adsorbates that lead to non-radiative recombination, and in the porous particles, the pore walls can quench fluorescence. This trend is valid across calcination temperatures and is evident when comparing particles from the same calcination temperature. PMID:28336860

  8. Small Bowel Dose Parameters Predicting Grade ≥3 Acute Toxicity in Rectal Cancer Patients Treated With Neoadjuvant Chemoradiation: An Independent Validation Study Comparing Peritoneal Space Versus Small Bowel Loop Contouring Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Banerjee, Robyn, E-mail: robynbanerjee@gmail.com; Chakraborty, Santam; Nygren, Ian

    Purpose: To determine whether volumes based on contours of the peritoneal space can be used instead of individual small bowel loops to predict for grade ≥3 acute small bowel toxicity in patients with rectal cancer treated with neoadjuvant chemoradiation therapy. Methods and Materials: A standardized contouring method was developed for the peritoneal space and retrospectively applied to the radiation treatment plans of 67 patients treated with neoadjuvant chemoradiation therapy for rectal cancer. Dose-volume histogram (DVH) data were extracted and analyzed against patient toxicity. Receiver operating characteristic analysis and logistic regression were carried out for both contouring methods. Results: Grade ≥3more » small bowel toxicity occurred in 16% (11/67) of patients in the study. A highly significant dose-volume relationship between small bowel irradiation and acute small bowel toxicity was supported by the use of both small bowel loop and peritoneal space contouring techniques. Receiver operating characteristic analysis demonstrated that, for both contouring methods, the greatest sensitivity for predicting toxicity was associated with the volume receiving between 15 and 25 Gy. Conclusion: DVH analysis of peritoneal space volumes accurately predicts grade ≥3 small bowel toxicity in patients with rectal cancer receiving neoadjuvant chemoradiation therapy, suggesting that the contours of the peritoneal space provide a reasonable surrogate for the contours of individual small bowel loops. The study finds that a small bowel V15 less than 275 cc and a peritoneal space V15 less than 830 cc are associated with a less than 10% risk of grade ≥3 acute toxicity.« less

  9. Energy Engineering Analysis Program (EEAP), Limited Energy Study-Lighting Fort Campbell, Kentucky: Volume 1-Sections 1-5

    DTIC Science & Technology

    1994-09-23

    Buildings, and Blanchfield Hospital buildings B and C. The energy conservation opportunities (ECOs) evaluated were high efficiency interior and exterior lighting, and indoor lighting controls . Cost estimates were prepared.

  10. Increased Anatomical Specificity of Neuromodulation via Modulated Focused Ultrasound

    PubMed Central

    Mehić, Edin; Xu, Julia M.; Caler, Connor J.; Coulson, Nathaniel K.; Moritz, Chet T.; Mourad, Pierre D.

    2014-01-01

    Transcranial ultrasound can alter brain function transiently and nondestructively, offering a new tool to study brain function now and inform future therapies. Previous research on neuromodulation implemented pulsed low-frequency (250–700 kHz) ultrasound with spatial peak temporal average intensities (ISPTA) of 0.1–10 W/cm2. That work used transducers that either insonified relatively large volumes of mouse brain (several mL) with relatively low-frequency ultrasound and produced bilateral motor responses, or relatively small volumes of brain (on the order of 0.06 mL) with relatively high-frequency ultrasound that produced unilateral motor responses. This study seeks to increase anatomical specificity to neuromodulation with modulated focused ultrasound (mFU). Here, ‘modulated’ means modifying a focused 2-MHz carrier signal dynamically with a 500-kHz signal as in vibro-acoustography, thereby creating a low-frequency but small volume (approximately 0.015 mL) source of neuromodulation. Application of transcranial mFU to lightly anesthetized mice produced various motor movements with high spatial selectivity (on the order of 1 mm) that scaled with the temporal average ultrasound intensity. Alone, mFU and focused ultrasound (FUS) each induced motor activity, including unilateral motions, though anatomical location and type of motion varied. Future work should include larger animal models to determine the relative efficacy of mFU versus FUS. Other studies should determine the biophysical processes through which they act. Also of interest is exploration of the potential research and clinical applications for targeted, transcranial neuromodulation created by modulated focused ultrasound, especially mFU’s ability to produce compact sources of ultrasound at the very low frequencies (10–100s of Hertz) that are commensurate with the natural frequencies of the brain. PMID:24504255

  11. Directed transport by surface chemical potential gradients for enhancing analyte collection in nanoscale sensors.

    PubMed

    Sitt, Amit; Hess, Henry

    2015-05-13

    Nanoscale detectors hold great promise for single molecule detection and the analysis of small volumes of dilute samples. However, the probability of an analyte reaching the nanosensor in a dilute solution is extremely low due to the sensor's small size. Here, we examine the use of a chemical potential gradient along a surface to accelerate analyte capture by nanoscale sensors. Utilizing a simple model for transport induced by surface binding energy gradients, we study the effect of the gradient on the efficiency of collecting nanoparticles and single and double stranded DNA. The results indicate that chemical potential gradients along a surface can lead to an acceleration of analyte capture by several orders of magnitude compared to direct collection from the solution. The improvement in collection is limited to a relatively narrow window of gradient slopes, and its extent strongly depends on the size of the gradient patch. Our model allows the optimization of gradient layouts and sheds light on the fundamental characteristics of chemical potential gradient induced transport.

  12. A correlative approach for combining microCT, light and transmission electron microscopy in a single 3D scenario

    PubMed Central

    2013-01-01

    Background In biomedical research, a huge variety of different techniques is currently available for the structural examination of small specimens, including conventional light microscopy (LM), transmission electron microscopy (TEM), confocal laser scanning microscopy (CLSM), microscopic X-ray computed tomography (microCT), and many others. Since every imaging method is physically limited by certain parameters, a correlative use of complementary methods often yields a significant broader range of information. Here we demonstrate the advantages of the correlative use of microCT, light microscopy, and transmission electron microscopy for the analysis of small biological samples. Results We used a small juvenile bivalve mollusc (Mytilus galloprovincialis, approximately 0.8 mm length) to demonstrate the workflow of a correlative examination by microCT, LM serial section analysis, and TEM-re-sectioning. Initially these three datasets were analyzed separately, and subsequently they were fused in one 3D scene. This workflow is very straightforward. The specimen was processed as usual for transmission electron microscopy including post-fixation in osmium tetroxide and embedding in epoxy resin. Subsequently it was imaged with microCT. Post-fixation in osmium tetroxide yielded sufficient X-ray contrast for microCT imaging, since the X-ray absorption of epoxy resin is low. Thereafter, the same specimen was serially sectioned for LM investigation. The serial section images were aligned and specific organ systems were reconstructed based on manual segmentation and surface rendering. According to the region of interest (ROI), specific LM sections were detached from the slides, re-mounted on resin blocks and re-sectioned (ultrathin) for TEM. For analysis, image data from the three different modalities was co-registered into a single 3D scene using the software AMIRA®. We were able to register both the LM section series volume and TEM slices neatly to the microCT dataset, with small geometric deviations occurring only in the peripheral areas of the specimen. Based on co-registered datasets the excretory organs, which were chosen as ROI for this study, could be investigated regarding both their ultrastructure as well as their position in the organism and their spatial relationship to adjacent tissues. We found structures typical for mollusc excretory systems, including ultrafiltration sites at the pericardial wall, and ducts leading from the pericardium towards the kidneys, which exhibit a typical basal infolding system. Conclusions The presented approach allows a comprehensive analysis and presentation of small objects regarding both the overall organization as well as cellular and subcellular details. Although our protocol involves a variety of different equipment and procedures, we maintain that it offers savings in both effort and cost. Co-registration of datasets from different imaging modalities can be accomplished with high-end desktop computers and offers new opportunities for understanding and communicating structural relationships within organisms and tissues. In general, the correlative use of different microscopic imaging techniques will continue to become more widespread in morphological and structural research in zoology. Classical TEM serial section investigations are extremely time consuming, and modern methods for 3D analysis of ultrastructure such as SBF-SEM and FIB-SEM are limited to very small volumes for examination. Thus the re-sectioning of LM sections is suitable for speeding up TEM examination substantially, while microCT could become a key-method for complementing ultrastructural examinations. PMID:23915384

  13. CT contrast predicts pancreatic cancer treatment response to verteporfin-based photodynamic therapy

    NASA Astrophysics Data System (ADS)

    Jermyn, Michael; Davis, Scott C.; Dehghani, Hamid; Huggett, Matthew T.; Hasan, Tayyaba; Pereira, Stephen P.; Bown, Stephen G.; Pogue, Brian W.

    2014-04-01

    The goal of this study was to determine dominant factors affecting treatment response in pancreatic cancer photodynamic therapy (PDT), based on clinically available information in the VERTPAC-01 trial. This trial investigated the safety and efficacy of verteporfin PDT in 15 patients with locally advanced pancreatic adenocarcinoma. CT scans before and after contrast enhancement from the 15 patients in the VERTPAC-01 trial were used to determine venous-phase blood contrast enhancement and this was correlated with necrotic volume determined from post-treatment CT scans, along with estimation of optical absorption in the pancreas for use in light modeling of the PDT treatment. Energy threshold contours yielded estimates for necrotic volume based on this light modeling. Both contrast-derived venous blood content and necrotic volume from light modeling yielded strong correlations with observed necrotic volume (R2 = 0.85 and 0.91, respectively). These correlations were much stronger than those obtained by correlating energy delivered versus necrotic volume in the VERTPAC-01 study and in retrospective analysis from a prior clinical study. This demonstrates that contrast CT can provide key surrogate dosimetry information to assess treatment response. It also implies that light attenuation is likely the dominant factor in the VERTPAC treatment response, as opposed to other factors such as drug distribution. This study is the first to show that contrast CT provides needed surrogate dosimetry information to predict treatment response in a manner which uses standard-of-care clinical images, rather than invasive dosimetry methods.

  14. Ultrahigh-speed Si-integrated on-chip laser with tailored dynamic characteristics

    NASA Astrophysics Data System (ADS)

    Park, Gyeong Cheol; Xue, Weiqi; Piels, Molly; Zibar, Darko; Mørk, Jesper; Semenova, Elizaveta; Chung, Il-Sug

    2016-12-01

    For on-chip interconnects, an ideal light source should have an ultralow energy consumption per bandwidth (operating en-ergy) as well as sufficient output power for error-free detection. Nanocavity lasers have been considered the most ideal for smaller operating energy. However, they have a challenge in obtaining a sufficient output power. Here, as an alternative, we propose an ultrahigh-speed microcavity laser structure, based on a vertical cavity with a high-contrast grating (HCG) mirror for transverse magnetic (TM) polarisation. By using the TM HCG, a very small mode volume and an un-pumped compact optical feedback structure can be realised, which together tailor the frequency response function for achieving a very high speed at low injection currents. Furthermore, light can be emitted laterally into a Si waveguide. From an 1.54-μm optically-pumped laser, a 3-dB frequency of 27 GHz was obtained at a pumping level corresponding to sub-mA. Using measured 3-dB frequen-cies and calculated equivalent currents, the modulation current efficiency factor (MCEF) is estimated to be 42.1 GHz/mA1/2, which is superior among microcavity lasers. This shows a high potential for a very high speed at low injection currents or avery small heat generation at high bitrates, which are highly desirable for both on-chip and off-chip applications.

  15. Optimal ventilation of the anesthetized pediatric patient.

    PubMed

    Feldman, Jeffrey M

    2015-01-01

    Mechanical ventilation of the pediatric patient is challenging because small changes in delivered volume can be a significant fraction of the intended tidal volume. Anesthesia ventilators have traditionally been poorly suited to delivering small tidal volumes accurately, and pressure-controlled ventilation has become used commonly when caring for pediatric patients. Modern anesthesia ventilators are designed to deliver small volumes accurately to the patient's airway by compensating for the compliance of the breathing system and delivering tidal volume independent of fresh gas flow. These technology advances provide the opportunity to implement a lung-protective ventilation strategy in the operating room based upon control of tidal volume. This review will describe the capabilities of the modern anesthesia ventilator and the current understanding of lung-protective ventilation. An optimal approach to mechanical ventilation for the pediatric patient is described, emphasizing the importance of using bedside monitors to optimize the ventilation strategy for the individual patient.

  16. Evaluation of sorghum flour functionality and quality characteristics of gluten-free bread and cake as influenced by ozone treatment.

    PubMed

    Marston, Kathryn; Khouryieh, Hanna; Aramouni, Fadi

    2015-12-01

    Commercially milled food-grade sorghum flour was subjected to ozone at the rate of 0.06 L/min for 15, 30, and 45 min. The pH of ozone-treated flour decreased as exposure time increased. The L* (lightness) values of sorghum flour significantly increased (p < 0.05), while the b* (yellowness) values significantly decreased as ozone exposure time increased. Peak viscosity significantly increased as time of ozonation increased from 0 to 45 min. Results showed that gluten-free cake volume significantly increased as ozonation time increased. Additionally, longer ozonation exposure times increased cells per slice area, lightness, and slice brightness values in gluten-free cakes while reducing crumb firmness. Despite improving lightness and slice brightness values, ozonation did not significantly increase the specific volume of gluten-free batter-based bread. While ozonation improved the volume and texture in cakes, it did not have the same positive effects on gluten-free bread. Bread made from ozonated sorghum flour had an open ragged structure with equivalent volume to the control flour. In both applications, the increased brightness and lightness values due to ozone exposure is recommended to increase the acceptability of sorghum products. © The Author(s) 2014.

  17. Endoclips vs large or small-volume epinephrine in peptic ulcer recurrent bleeding

    PubMed Central

    Ljubicic, Neven; Budimir, Ivan; Biscanin, Alen; Nikolic, Marko; Supanc, Vladimir; Hrabar, Davor; Pavic, Tajana

    2012-01-01

    AIM: To compare the recurrent bleeding after endoscopic injection of different epinephrine volumes with hemoclips in patients with bleeding peptic ulcer. METHODS: Between January 2005 and December 2009, 150 patients with gastric or duodenal bleeding ulcer with major stigmata of hemorrhage and nonbleeding visible vessel in an ulcer bed (Forrest IIa) were included in the study. Patients were randomized to receive a small-volume epinephrine group (15 to 25 mL injection group; Group 1, n = 50), a large-volume epinephrine group (30 to 40 mL injection group; Group 2, n = 50) and a hemoclip group (Group 3, n = 50). The rate of recurrent bleeding, as the primary outcome, was compared between the groups of patients included in the study. Secondary outcomes compared between the groups were primary hemostasis rate, permanent hemostasis, need for emergency surgery, 30 d mortality, bleeding-related deaths, length of hospital stay and transfusion requirements. RESULTS: Initial hemostasis was obtained in all patients. The rate of early recurrent bleeding was 30% (15/50) in the small-volume epinephrine group (Group 1) and 16% (8/50) in the large-volume epinephrine group (Group 2) (P = 0.09). The rate of recurrent bleeding was 4% (2/50) in the hemoclip group (Group 3); the difference was statistically significant with regard to patients treated with either small-volume or large-volume epinephrine solution (P = 0.0005 and P = 0.045, respectively). Duration of hospital stay was significantly shorter among patients treated with hemoclips than among patients treated with epinephrine whereas there were no differences in transfusion requirement or even 30 d mortality between the groups. CONCLUSION: Endoclip is superior to both small and large volume injection of epinephrine in the prevention of recurrent bleeding in patients with peptic ulcer. PMID:22611315

  18. Pulsed Direct Current Electrospray: Enabling Systematic Analysis of Small Volume Sample by Boosting Sample Economy.

    PubMed

    Wei, Zhenwei; Xiong, Xingchuang; Guo, Chengan; Si, Xingyu; Zhao, Yaoyao; He, Muyi; Yang, Chengdui; Xu, Wei; Tang, Fei; Fang, Xiang; Zhang, Sichun; Zhang, Xinrong

    2015-11-17

    We had developed pulsed direct current electrospray ionization mass spectrometry (pulsed-dc-ESI-MS) for systematically profiling and determining components in small volume sample. Pulsed-dc-ESI utilized constant high voltage to induce the generation of single polarity pulsed electrospray remotely. This method had significantly boosted the sample economy, so as to obtain several minutes MS signal duration from merely picoliter volume sample. The elongated MS signal duration enable us to collect abundant MS(2) information on interested components in a small volume sample for systematical analysis. This method had been successfully applied for single cell metabolomics analysis. We had obtained 2-D profile of metabolites (including exact mass and MS(2) data) from single plant and mammalian cell, concerning 1034 components and 656 components for Allium cepa and HeLa cells, respectively. Further identification had found 162 compounds and 28 different modification groups of 141 saccharides in a single Allium cepa cell, indicating pulsed-dc-ESI a powerful tool for small volume sample systematical analysis.

  19. Ecological consequences of artificial night lighting

    USDA-ARS?s Scientific Manuscript database

    This edited volume is the best source for the increasingly recognized impact of artificial night lighting on the living world. Fifteen chapters cover effects of artificial lighting on mammals, birds, reptiles, amphibians, fishes, invertebrates (mostly insects), and plants. The book was an outgrowt...

  20. Plant lighting system with five wavelength-band light-emitting diodes providing photon flux density and mixing ratio control

    PubMed Central

    2012-01-01

    Background Plant growth and development depend on the availability of light. Lighting systems therefore play crucial roles in plant studies. Recent advancements of light-emitting diode (LED) technologies provide abundant opportunities to study various plant light responses. The LED merits include solidity, longevity, small element volume, radiant flux controllability, and monochromaticity. To apply these merits in plant light response studies, a lighting system must provide precisely controlled light spectra that are useful for inducing various plant responses. Results We have developed a plant lighting system that irradiated a 0.18 m2 area with a highly uniform distribution of photon flux density (PFD). The average photosynthetic PFD (PPFD) in the irradiated area was 438 micro-mol m–2 s–1 (coefficient of variation 9.6%), which is appropriate for growing leafy vegetables. The irradiated light includes violet, blue, orange-red, red, and far-red wavelength bands created by LEDs of five types. The PFD and mixing ratio of the five wavelength-band lights are controllable using a computer and drive circuits. The phototropic response of oat coleoptiles was investigated to evaluate plant sensitivity to the light control quality of the lighting system. Oat coleoptiles irradiated for 23 h with a uniformly distributed spectral PFD (SPFD) of 1 micro-mol m–2 s–1 nm–1 at every peak wavelength (405, 460, 630, 660, and 735 nm) grew almost straight upwards. When they were irradiated with an SPFD gradient of blue light (460 nm peak wavelength), the coleoptiles showed a phototropic curvature in the direction of the greater SPFD of blue light. The greater SPFD gradient induced the greater curvature of coleoptiles. The relation between the phototropic curvature (deg) and the blue-light SPFD gradient (micro-mol m–2 s–1 nm–1 m–1) was 2 deg per 1 micro-mol m–2 s–1 nm–1 m–1. Conclusions The plant lighting system, with a computer with a graphical user interface program, can control the PFD and mixing ratios of five wavelength-band lights. A highly uniform PFD distribution was achieved, although an intentionally distorted PFD gradient was also created. Phototropic responses of oat coleoptiles to the blue light gradient demonstrated the merit of fine controllability of this plant lighting system. PMID:23173915

  1. The effect of light on lake herring (Coregonus artedi) reactive volume

    USGS Publications Warehouse

    Link, Jason; Edsall, Thomas A.

    1996-01-01

    The lake herring (Coregonus artedi) is an important coldwater planktivore in the Laurentian Great Lakes and in smaller inland lakes in portions of Canada and the northern United States. Lake herring cruise the pelagia and feed selectively in both gulping and particulate modes. They are visual predators in environments with adequate illumination. Visual predation by fish consists of a series of discrete steps. We studied the first step in the predation sequence, reaction to prey, at light intensities of 2–1500 Lx in a simulated pelagic environment at 10–13°C. We measured lake herring reactive distances, the distance at which a prey item will be detected and attacked, to liveLimnocalanus macrurus, a natural prey of lake herring in Lake Superior. We used the reactive distances and associated angles of bearing and elevation, which described the location of the prey relative to the lake herring, to calculate reactive volume. This reactive volume can be envisioned as an irregular sphere surrounding the fish, within which prey are detected and attacked. All of the attacks on prey occurred in the anterior portions of the sagittal and lateral planes of the lake herring, as would be expected for a pelagic, cruising fish. The reactive volume surrounding the lake herring was generally spherical, but was more irregular than the simple spheres, hemispheres, cylinders, cones or other geometries assumed in previous studies. The reactive distances and the reactive volume changed with light intensity and were significantly smaller at 2–10 Lx than at 40–1500 Lx. At 40–1500 Lx, the reactive volume was expanded over that observed at 2–10 Lx laterally and caudally. Collectively our results indicate that lake herring can visually forage most effectively in environments with light levels >10 Lx.

  2. Noninvasive in vivo plasma volume and hematocrit in humans: observing long-term baseline behavior to establish homeostasis for intravascular volume and composition

    NASA Astrophysics Data System (ADS)

    Dent, Paul; Deng, Bin; Goodisman, Jerry; Peterson, Charles M.; Narsipur, Sriram; Chaiken, J.

    2016-04-01

    A new device incorporating a new algorithm and measurement process allows simultaneous noninvasive in vivo monitoring of intravascular plasma volume and red blood cell volume. The purely optical technique involves probing fingertip skin with near infrared laser light and collecting the wavelength shifted light, that is, the inelastic emission (IE) which includes the unresolved Raman and fluorescence, and the un-shifted emission, that is, the elastic emission (EE) which includes both the Rayleigh and Mie scattered light. Our excitation and detection geometry is designed so that from these two simultaneous measurements we can calculate two parameters within the single scattering regime using radiation transfer theory, the intravascular plasma volume fraction and the red blood cell volume fraction. Previously calibrated against a gold standard FDA approved device, 2 hour monitoring sessions on three separate occasions over a three week span for a specific, motionless, and mostly sleeping individual produced 3 records containing a total of 5706 paired measurements of hematocrit and plasma volume. The average over the three runs, relative to the initial plasma volume taken as 100%, of the plasma volume±1σ was 97.56+/-0.55 or 0.56%.For the same three runs, the average relative hematocrit (Hct), referenced to an assumed initial value of 28.35 was 29.37+/-0.12 or stable to +/-0.4%.We observe local deterministic circulation effects apparently associated with the pressure applied by the finger probe as well as longer timescale behavior due to normal ebb and flow of internal fluids due to posture changes and tilt table induced gravity gradients.

  3. Brain-volume changes in young and middle-aged smokers: a DARTEL-based voxel-based morphometry study.

    PubMed

    Peng, Peng; Wang, Zhenchang; Jiang, Tao; Chu, Shuilian; Wang, Shuangkun; Xiao, Dan

    2017-09-01

    Many studies have reported brain volume changes in smokers. However, the volume differences of grey matter (GM) and white matter (WM) in young and middle-aged male smokers with different lifetime tobacco consumption (pack-years) remain uncertain. To examine the brain volume change, especially whether more pack-years smoking would be associated with smaller gray matter and white matter volume in young and middle-aged male smokers. We used a 3T MR scanner and performed Diffeomorphic anatomical registration through exponentiated lie algebra (DARTEL)-based voxel-based morphometry on 53 long-term male smokers (30.72 ± 4.19 years) and 53 male healthy non-smokers (30.83 ± 5.18 years). We separated smokers to light and heavy smokers by pack-years and compared brain volume between different smoker groups and non-smokers. And then we did analysis of covariance (ANCOVA) between smokers and non-smokers by setting pack-years as covariates. Light and heavy smokers all displayed smaller GM and WM volume than non-smokers and more obviously in heavy smokers. The main smaller areas in light and heavy smokers were superior temporal gyrus, insula, middle occipital gyrus, posterior cingulate, precuneus in GM and posterior cingulate, thalamus and midbrain in WM, in addition, we also observed more pack-years smoking was associated with some certain smaller GM and WM volumes by ANCOVA. Young and middle-aged male smokers had many smaller brain areas than non-smokers. Some of these areas' volume had negative correlation with pack-years, while some had not. These may due to different pathophysiological role of smokings. © 2015 John Wiley & Sons Ltd.

  4. Frequency domain fluorescence diffuse tomography of small animals

    NASA Astrophysics Data System (ADS)

    Orlova, Anna G.; Turchin, Ilya V.; Kamensky, Vladislav A.; Plehanov, Vladimir I.; Balalaeva, Irina V.; Sergeeva, Ekaterina A.; Shirmanova, Marina V.; Kleshnin, Michail S.

    2007-05-01

    Fluorescent compounds for selective cancer cell marking are used for development of novel medical diagnostic methods, investigation of the influence of external factors on tumor growth, regress and metastasis. Only special tools for turbid media imaging, such as optical diffusion tomography permit noninvasive monitoring of fluorescent-labeled tumor alterations deep in animal tissue. In this work, the results of preliminary experiments utilizing frequency-domain fluorescent diffusion tomography (FD FDT) experimental setup in small animal are presented. Low-frequency modulated light (1 kHz) from Nd:YAG laser with second harmonic generation at the wavelength of 532 nm was used in the setup. The transilluminative planar configuration was used in the setup. A series of model experiments has been conducted and show good agreement between theoretical and experimental fluorescence intensity. Models of deep tumors were created by two methods: (1) glass capsules containing fluorophore solution were inserted into esophagus of small animals to simulate marked tumors; (2) a suspension of transfected HEΚ293-Turbo-RFP cells was subcutaneously injected to small animal. The conducted experiments have shown that FD FDT allows one to detect the presence of labeled tumor cells in small animals, to determine the volume of an experimental tumor, to perform 3D tumor reconstruction, as well as to conduct monitoring investigations. The obtained results demonstrate the potential capability of the FD FDT method for noninvasive whole-body imaging in cancer studies, diagnostics and therapy.

  5. Small Business Management Volume III: Curriculum. An Adult Education Program.

    ERIC Educational Resources Information Center

    Persons, Edgar A.; Swanson, Gordon I.

    The small business management adult education program outlined in this curriculum guide is designed to help small business entrepreneurs solve their business management problems and attain the goals they have established for their businesses and their families. (An instructor's manual and practice problems are in separate volumes.) The 3-year…

  6. 40 CFR 80.250 - How is the small refiner sulfur baseline and volume determined?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 17 2012-07-01 2012-07-01 false How is the small refiner sulfur... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Sulfur Hardship Provisions § 80.250 How is the small refiner sulfur baseline and volume determined? (a)(1) The...

  7. 40 CFR 80.250 - How is the small refiner sulfur baseline and volume determined?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 16 2011-07-01 2011-07-01 false How is the small refiner sulfur... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Sulfur Hardship Provisions § 80.250 How is the small refiner sulfur baseline and volume determined? (a)(1) The...

  8. 40 CFR 80.250 - How is the small refiner sulfur baseline and volume determined?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 17 2014-07-01 2014-07-01 false How is the small refiner sulfur... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Sulfur Hardship Provisions § 80.250 How is the small refiner sulfur baseline and volume determined? (a)(1) The...

  9. 40 CFR 80.250 - How is the small refiner sulfur baseline and volume determined?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 17 2013-07-01 2013-07-01 false How is the small refiner sulfur... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Sulfur Hardship Provisions § 80.250 How is the small refiner sulfur baseline and volume determined? (a)(1) The...

  10. 40 CFR 80.250 - How is the small refiner sulfur baseline and volume determined?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false How is the small refiner sulfur... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Gasoline Sulfur Hardship Provisions § 80.250 How is the small refiner sulfur baseline and volume determined? (a)(1) The...

  11. Large-scale tomographic particle image velocimetry using helium-filled soap bubbles

    NASA Astrophysics Data System (ADS)

    Kühn, Matthias; Ehrenfried, Klaus; Bosbach, Johannes; Wagner, Claus

    2011-04-01

    To measure large-scale flow structures in air, a tomographic particle image velocimetry (tomographic PIV) system for measurement volumes of the order of one cubic metre is developed, which employs helium-filled soap bubbles (HFSBs) as tracer particles. The technique has several specific characteristics compared to most conventional tomographic PIV systems, which are usually applied to small measurement volumes. One of them is spot lights on the HFSB tracers, which slightly change their position, when the direction of observation is altered. Further issues are the large particle to voxel ratio and the short focal length of the used camera lenses, which result in a noticeable variation of the magnification factor in volume depth direction. Taking the specific characteristics of the HFSBs into account, the feasibility of our large-scale tomographic PIV system is demonstrated by showing that the calibration errors can be reduced down to 0.1 pixels as required. Further, an accurate and fast implementation of the multiplicative algebraic reconstruction technique, which calculates the weighting coefficients when needed instead of storing them, is discussed. The tomographic PIV system is applied to measure forced convection in a convection cell at a Reynolds number of 530 based on the inlet channel height and the mean inlet velocity. The size of the measurement volume and the interrogation volumes amount to 750 mm × 450 mm × 165 mm and 48 mm × 48 mm × 24 mm, respectively. Validation of the tomographic PIV technique employing HFSBs is further provided by comparing profiles of the mean velocity and of the root mean square velocity fluctuations to respective planar PIV data.

  12. Speed-volume relationship and headway distribution analysis of motorcycle (case study: Teuku Nyak Arief Road)

    NASA Astrophysics Data System (ADS)

    Prahara, E.; Prasetya, R. A.

    2018-01-01

    In many developing countries, transportation modes are more varied than the other country. For example, in Jakarta, Indonesia, in some roadway, motorcycle is the most dominant vehicle, with total volume is four times higher than a passenger car. Thus, the traffic characteristic in motorcycle-dominated traffic differs from a common traffic situation. The purpose of this study is to apply the concept and theory developed to analyze motorcycle behaviour under motorcycle-dominated traffic condition. The survey is applied by recording the traffic flow movement of research location at specified time period. The macroscopic characteristic analyzed in this research is a speed-flow relationship based on motorcycle equivalent unit (MCU). Furthermore, a detail microscopic characteristic analyzed that is motorcycle time headway regarding traffic flow. MCU values computed were consists of motorcycle (MC), light vehicle (LV) and heavy vehicle (HV). Those values were calculated 1.00, 6.13 and 10.71 respectively. The speed and volume relationship result is showing a linear regression model with R2 value is 0.58, it can be explained that the correlation between two variables is intermediate. The headway distribution of motorcycle is compatible with the negative exponential distribution which fitted with the proposed theory for a small vehicle such as a motorcycle.

  13. A scanning transmission electron microscopy approach to analyzing large volumes of tissue to detect nanoparticles.

    PubMed

    Kempen, Paul J; Thakor, Avnesh S; Zavaleta, Cristina; Gambhir, Sanjiv S; Sinclair, Robert

    2013-10-01

    The use of nanoparticles for the diagnosis and treatment of cancer requires the complete characterization of their toxicity, including accurately locating them within biological tissues. Owing to their size, traditional light microscopy techniques are unable to resolve them. Transmission electron microscopy provides the necessary spatial resolution to image individual nanoparticles in tissue, but is severely limited by the very small analysis volume, usually on the order of tens of cubic microns. In this work, we developed a scanning transmission electron microscopy (STEM) approach to analyze large volumes of tissue for the presence of polyethylene glycol-coated Raman-active-silica-gold-nanoparticles (PEG-R-Si-Au-NPs). This approach utilizes the simultaneous bright and dark field imaging capabilities of STEM along with careful control of the image contrast settings to readily identify PEG-R-Si-Au-NPs in mouse liver tissue without the need for additional time-consuming analytical characterization. We utilized this technique to analyze 243,000 mm³ of mouse liver tissue for the presence of PEG-R-Si-Au-NPs. Nanoparticles injected into the mice intravenously via the tail vein accumulated in the liver, whereas those injected intrarectally did not, indicating that they remain in the colon and do not pass through the colon wall into the systemic circulation.

  14. Heat capacity measurements of sub-nanoliter volumes of liquids using bimaterial microchannel cantilevers

    NASA Astrophysics Data System (ADS)

    Khan, M. F.; Miriyala, N.; Lee, J.; Hassanpourfard, M.; Kumar, A.; Thundat, T.

    2016-05-01

    Lab-on-a-Chip compatible techniques for thermal characterization of miniaturized volumes of liquid analytes are necessary in applications such as protein blotting, DNA melting, and drug development, where samples are either rare or volume-limited. We developed a closed-chamber calorimeter based on a bimaterial microchannel cantilever (BMC) for sub-nanoliter level thermal analysis. When the liquid-filled BMC is irradiated with infrared (IR) light at a specific wavelength, the IR absorption by the liquid analyte results in localized heat generation and the subsequent deflection of the BMC, due to a thermal expansion mismatch between the constituent materials. The time constant of the deflection, which is dependent upon the heat capacity of the liquid analyte, can be directly measured by recording the time-dependent bending of the BMC. We have used the BMC to quantitatively measure the heat capacity of five volatile organic compounds. With a deflection noise level of ˜10 nm and a signal-to-noise ratio of 68:1, the BMC offers a sensitivity of 30.5 ms/(J g-1 K-1) and a resolution of 23 mJ/(g K) for ˜150 pl liquid for heat capacity measurements. This technique can be used for small-scale thermal characterization of different chemical and biological samples.

  15. A Scanning Transmission Electron Microscopy (STEM) Approach to Analyzing Large Volumes of Tissue to Detect Nanoparticles

    PubMed Central

    Kempen, Paul J.; Thakor, Avnesh S.; Zavaleta, Cristina; Gambhir, Sanjiv S.; Sinclair, Robert

    2013-01-01

    The use of nanoparticles for the diagnosis and treatment of cancer requires the complete characterization of their toxicity, including accurately locating them within biological tissues. Owing to their size, traditional light microscopy techniques are unable to resolve them. Transmission electron microscopy provides the necessary spatial resolution to image individual nanoparticles in tissue but is severely limited by the very small analysis volume, usually on the order of tens of cubic microns. In this work we developed a scanning transmission electron microscopy (STEM) approach to analyze large volumes of tissue for the presence of polyethylene glycol coated Raman-active-silica-gold-nanoparticles (PEG-R-Si-Au-NPs). This approach utilizes the simultaneous bright and dark field imaging capabilities of STEM along with careful control of the image contrast settings to readily identify PEG-R-Si-Au-NPs in mouse liver tissue without the need for additional time consuming analytical characterization. We utilized this technique to analyze 243,000 µm3 of mouse liver tissue for the presence of PEG-R-Si-Au-NPs. Nanoparticles injected into the mice intravenously via the tail-vein accumulated in the liver while those injected intrarectally did not, indicating that they remain in the colon and do not pass through the colon wall into the systemic circulation. PMID:23803218

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Woohyun; Katipamula, Srinivas; Lutes, Robert G.

    This report describes how the intelligent load control (ILC) algorithm can be implemented to achieve peak demand reduction while minimizing impacts on occupant comfort. The algorithm was designed to minimize the additional sensors and minimum configuration requirements to enable a scalable and cost-effective implementation for both large and small-/medium-sized commercial buildings. The ILC algorithm uses an analytic hierarchy process (AHP) to dynamically prioritize the available curtailable loads based on both quantitative (deviation of zone conditions from set point) and qualitative rules (types of zone). Although the ILC algorithm described in this report was highly tailored to work with rooftop units,more » it can be generalized for application to other building loads such as variable-air-volume (VAV) boxes and lighting systems.« less

  17. Potato leaf explants as a spaceflight plant test system

    NASA Technical Reports Server (NTRS)

    Wheeler, R. M.

    1986-01-01

    The use of explant tissues or organs may circumvent limitations facing whole-plant experimentation during spaceflight. In the case of potato, a crop currently being studied for application to bioregenerative life support systems, excised leaves and their subtended axillary buds can be used to test a variety of stem growth and development phases ranging from tubers through stolons (horizontal stems) to upright leafy shoots. The leaves can be fit well into small-volume test packages and sustained under relatively low irradiance levels using light-weight growing media. Tubers formed on potato leaf cuttings can yield up from 0.5 to 1.0 g fresh mass 10 days after excision and up to 2.0 g or more, 14 days from excision.

  18. A Numerical Investigation of the Startup Transient in a Wave Rotor

    NASA Technical Reports Server (NTRS)

    Paxson, Daniel E.

    1996-01-01

    The startup process is investigated for a hypothetical four-port wave rotor, envisioned as a topping cycle for a small gas turbine engine. The investigation is conducted numerically using a multi-passage, one-dimensional CFD-based wave rotor simulation in combination with lumped volume models for the combustor, exhaust valve plenum, and rotor center cavity components. The simulation is described and several startup transients are presented which illustrate potential difficulties for the specific cycle design investigated. In particular it is observed that, prior to combustor light-off, or just after, the flow through the combustor loop is reversed from the design direction. The phenomenon is demonstrated and several possible modifications techniques are discussed which avoid or overcome the problem.

  19. Compact intra-cavity frequency doubled line beam green laser by a laser diode array pumped

    NASA Astrophysics Data System (ADS)

    Yan, Boxia; Qi, Yan; Wang, Yanwei

    2016-10-01

    Compact, high power, and low-cost green laser light sources are needed in projection-related applications such as digital cinema, rear-projection television, simulators, and command and control stations. We report a LD array directly pumped intracavity SHG Nd:YVO4/PPMgLN laser without lens or waveguide in this letter. A compact 3.12 W green laser was demonstrated by intra-cavity frequency doubled using a PPMgLN bulk crystal by a 19-emitter LD array pumped(single bar), the conversion efficiency from input LD array was 9.2%. A line-beam output suitable for laser projectors was generated, which has the potential to be scalable to small volumes and low costs for laser projection displays.

  20. One-step synthesis of hierarchically porous hybrid TiO2 hollow spheres with high photocatalytic activity

    NASA Astrophysics Data System (ADS)

    Liu, Ruiping; Ren, Feng; Yang, Jinlin; Su, Weiming; Sun, Zhiming; Zhang, Lei; Wang, Chang-an

    2016-03-01

    Hierarchically porous hybrid TiO2 hollow spheres were solvothermally synthesized successfully by using tetrabutyl titanate as titanium precursor and hydrated metal sulfates as soft templates. The as-prepared TiO2 spheres with hierarchically pore structures and high specific surface area and pore volume consisted of highly crystallized anatase TiO2 nanocrystals hybridized with a small amount of metal oxide from the hydrated sulfate. The proposed hydrated-sulfate assisted solvothermal (HAS) synthesis strategy was demonstrated to be widely applicable to various systems. Evaluation of the hybrid TiO2 hollow spheres for the photo-decomposition of methyl orange (MO) under visible-light irradiation revealed that they exhibited excellent photocatalytic activity and durability.

  1. Enhancing the performance of the light field microscope using wavefront coding

    PubMed Central

    Cohen, Noy; Yang, Samuel; Andalman, Aaron; Broxton, Michael; Grosenick, Logan; Deisseroth, Karl; Horowitz, Mark; Levoy, Marc

    2014-01-01

    Light field microscopy has been proposed as a new high-speed volumetric computational imaging method that enables reconstruction of 3-D volumes from captured projections of the 4-D light field. Recently, a detailed physical optics model of the light field microscope has been derived, which led to the development of a deconvolution algorithm that reconstructs 3-D volumes with high spatial resolution. However, the spatial resolution of the reconstructions has been shown to be non-uniform across depth, with some z planes showing high resolution and others, particularly at the center of the imaged volume, showing very low resolution. In this paper, we enhance the performance of the light field microscope using wavefront coding techniques. By including phase masks in the optical path of the microscope we are able to address this non-uniform resolution limitation. We have also found that superior control over the performance of the light field microscope can be achieved by using two phase masks rather than one, placed at the objective’s back focal plane and at the microscope’s native image plane. We present an extended optical model for our wavefront coded light field microscope and develop a performance metric based on Fisher information, which we use to choose adequate phase masks parameters. We validate our approach using both simulated data and experimental resolution measurements of a USAF 1951 resolution target; and demonstrate the utility for biological applications with in vivo volumetric calcium imaging of larval zebrafish brain. PMID:25322056

  2. Enhancing the performance of the light field microscope using wavefront coding.

    PubMed

    Cohen, Noy; Yang, Samuel; Andalman, Aaron; Broxton, Michael; Grosenick, Logan; Deisseroth, Karl; Horowitz, Mark; Levoy, Marc

    2014-10-06

    Light field microscopy has been proposed as a new high-speed volumetric computational imaging method that enables reconstruction of 3-D volumes from captured projections of the 4-D light field. Recently, a detailed physical optics model of the light field microscope has been derived, which led to the development of a deconvolution algorithm that reconstructs 3-D volumes with high spatial resolution. However, the spatial resolution of the reconstructions has been shown to be non-uniform across depth, with some z planes showing high resolution and others, particularly at the center of the imaged volume, showing very low resolution. In this paper, we enhance the performance of the light field microscope using wavefront coding techniques. By including phase masks in the optical path of the microscope we are able to address this non-uniform resolution limitation. We have also found that superior control over the performance of the light field microscope can be achieved by using two phase masks rather than one, placed at the objective's back focal plane and at the microscope's native image plane. We present an extended optical model for our wavefront coded light field microscope and develop a performance metric based on Fisher information, which we use to choose adequate phase masks parameters. We validate our approach using both simulated data and experimental resolution measurements of a USAF 1951 resolution target; and demonstrate the utility for biological applications with in vivo volumetric calcium imaging of larval zebrafish brain.

  3. Infrared astronomical satellite (IRAS) catalogs and atlases. Volume 7: The small scale structure catalog

    NASA Technical Reports Server (NTRS)

    Helou, George (Editor); Walker, D. W. (Editor)

    1988-01-01

    The Infrared Astronomical Satellite (IRAS) was launched January 26, 1983. During its 300-day mission, it surveyed over 96 pct of the celestial sphere at four infrared wavelengths, centered approximately at 12, 25, 60, and 100 microns. Volume 1 describes the instrument, the mission, and the data reduction process. Volumes 2 through 6 present the observations of the approximately 245,000 individual point sources detected by IRAS; each volume gives sources within a specified range of declination. Volume 7 gives the observations of the approximately 16,000 sources spatially resolved by IRAS and smaller than 8'. This is Volume 7, The Small Scale Structure Catalog.

  4. Validation of a White-light 3D Body Volume Scanner to Assess Body Composition.

    PubMed

    Medina-Inojosa, Jose; Somers, Virend; Jenkins, Sarah; Zundel, Jennifer; Johnson, Lynne; Grimes, Chassidy; Lopez-Jimenez, Francisco

    2017-01-01

    Estimating body fat content has shown to be a better predictor of adiposity-related cardiovascular risk than the commonly used body mass index (BMI). The white-light 3D body volume index (BVI) scanner is a non-invasive device normally used in the clothing industry to assess body shapes and sizes. We assessed the hypothesis that volume obtained by BVI is comparable to the volume obtained by air displacement plethysmography (Bod-Pod) and thus capable of assessing body fat mass using the bi-compartmental principles of body composition. We compared BVI to Bod-pod, a validated bicompartmental method to assess body fat percent that uses pressure/volume relationships in isothermal conditions to estimate body volume. Volume is then used to calculate body density (BD) applying the formula density=Body Mass/Volume. Body fat mass percentage is then calculated using the Siri formula (4.95/BD - 4.50) × 100. Subjects were undergoing a wellness evaluation. Measurements from both devices were obtained the same day. A prediction model for total Bod-pod volume was developed using linear regression based on 80% of the observations (N=971), as follows: Predicted Bod-pod Volume (L)=9.498+0.805*(BVI volume, L)-0.0411*(Age, years)-3.295*(Male=0, Female=1)+0.0554*(BVI volume, L)*(Male=0, Female=1)+0.0282*(Age, years)*(Male=0, Female=1). Predictions for Bod-pod volume based on the estimated model were then calculated for the remaining 20% (N=243) and compared to the volume measured by the Bod-pod. Mean age among the 971 individuals was 41.5 ± 12.9 years, 39.4% were men, weight 81.6 ± 20.9 kg, BMI was 27.8 ± 6.3kg/m 2 . Average difference between volume measured by Bod-pod- predicted volume by BVI was 0.0 L, median: -0.4 L, IQR: -1.8 L to 1.5 L, R2=0.9845. Average difference between body fat measured-predicted was-1%, median: -2.7%, IQR: -13.2 to 9.9, R2=0.9236. Volume and BFM can be estimated by using volume measurements obtained by a white- light 3D body scanner and the prediction model developed in this study.

  5. Accurate measurement of volume and shape of resting and activated blood platelets from light scattering.

    PubMed

    Moskalensky, Alexander E; Yurkin, Maxim A; Konokhova, Anastasiya I; Strokotov, Dmitry I; Nekrasov, Vyacheslav M; Chernyshev, Andrei V; Tsvetovskaya, Galina A; Chikova, Elena D; Maltsev, Valeri P

    2013-01-01

    We introduce a novel approach for determination of volume and shape of individual blood platelets modeled as an oblate spheroid from angle-resolved light scattering with flow-cytometric technique. The light-scattering profiles (LSPs) of individual platelets were measured with the scanning flow cytometer and the platelet characteristics were determined from the solution of the inverse light-scattering problem using the precomputed database of theoretical LSPs. We revealed a phenomenon of parameter compensation, which is partly explained in the framework of anomalous diffraction approximation. To overcome this problem, additional a priori information on the platelet refractive index was used. It allowed us to determine the size of each platelet with subdiffraction precision and independent of the particular value of the platelet aspect ratio. The shape (spheroidal aspect ratio) distributions of platelets showed substantial differences between native and activated by 10 μM adenosine diphosphate samples. We expect that the new approach may find use in hematological analyzers for accurate measurement of platelet volume distribution and for determination of the platelet activation efficiency.

  6. Structure and function of the mammalian middle ear. I: Large middle ears in small desert mammals.

    PubMed

    Mason, Matthew J

    2016-02-01

    Many species of small desert mammals are known to have expanded auditory bullae. The ears of gerbils and heteromyids have been well described, but much less is known about the middle ear anatomy of other desert mammals. In this study, the middle ears of three gerbils (Meriones, Desmodillus and Gerbillurus), two jerboas (Jaculus) and two sengis (elephant-shrews: Macroscelides and Elephantulus) were examined and compared, using micro-computed tomography and light microscopy. Middle ear cavity expansion has occurred in members of all three groups, apparently in association with an essentially 'freely mobile' ossicular morphology and the development of bony tubes for the middle ear arteries. Cavity expansion can occur in different ways, resulting in different subcavity patterns even between different species of gerbils. Having enlarged middle ear cavities aids low-frequency audition, and several adaptive advantages of low-frequency hearing to small desert mammals have been proposed. However, while Macroscelides was found here to have middle ear cavities so large that together they exceed brain volume, the bullae of Elephantulus are considerably smaller. Why middle ear cavities are enlarged in some desert species but not others remains unclear, but it may relate to microhabitat. © 2015 Anatomical Society.

  7. Light Helicopter Family Trade-Off Analysis. Volume 4. Appendix N

    DTIC Science & Technology

    1985-05-15

    Figur«! N -V1I-9 through N -VII-U ahow th« futl flow CMp«rlsoas chac comt|>oad r.o th« powar r«qutr«««nt* thown by flguraa (J-VII-l through M-VII-4...HELICOPTER. FAMILY TRADE-OFF ANALYSIS APPENDIX N VOLUME IV ACN: 69396 • Copy l_Q] of 130 c:optea. 15 Nay 198S ~ .. 8 06 .0&1 OTIC ELECTE AU613...TITLE (- ..... do) I. TYPf ’!! ~POitT a PI!I’IOD COVI:IU!O LIGHT HELICOPTER FAMILY TRADE-OFF ANALYSIS, Fina t y Report, APPENDIX N , VOLUME IV of XI

  8. Archimedes Revisited: A Faster, Better, Cheaper Method of Accurately Measuring the Volume of Small Objects

    ERIC Educational Resources Information Center

    Hughes, Stephen W.

    2005-01-01

    A little-known method of measuring the volume of small objects based on Archimedes' principle is described, which involves suspending an object in a water-filled container placed on electronic scales. The suspension technique is a variation on the hydrostatic weighing technique used for measuring volume. The suspension method was compared with two…

  9. Micron-scale lens array having diffracting structures

    DOEpatents

    Goldberg, Kenneth A

    2013-10-29

    A novel micron-scale lens, a microlens, is engineered to concentrate light efficiently onto an area of interest, such as a small, light-sensitive detector element in an integrated electronic device. Existing microlens designs imitate the form of large-scale lenses and are less effective at small sizes. The microlenses described herein have been designed to accommodate diffraction effects, which dominate the behavior of light at small length scales. Thus a new class of light-concentrating optical elements with much higher relative performance has been created. Furthermore, the new designs are much easier to fabricate than previous designs.

  10. Antarctic icebergs distributions 1992-2014

    NASA Astrophysics Data System (ADS)

    Tournadre, J.; Bouhier, N.; Girard-Ardhuin, F.; Rémy, F.

    2016-01-01

    Basal melting of floating ice shelves and iceberg calving constitute the two almost equal paths of freshwater flux between the Antarctic ice cap and the Southern Ocean. The largest icebergs (>100 km2) transport most of the ice volume but their basal melting is small compared to their breaking into smaller icebergs that constitute thus the major vector of freshwater. The archives of nine altimeters have been processed to create a database of small icebergs (<8 km2) within open water containing the positions, sizes, and volumes spanning the 1992-2014 period. The intercalibrated monthly ice volumes from the different altimeters have been merged in a homogeneous 23 year climatology. The iceberg size distribution, covering the 0.1-10,000 km2 range, estimated by combining small and large icebergs size measurements follows well a power law of slope -1.52 ± 0.32 close to the -3/2 laws observed and modeled for brittle fragmentation. The global volume of ice and its distribution between the ocean basins present a very strong interannual variability only partially explained by the number of large icebergs. Indeed, vast zones of the Southern Ocean free of large icebergs are largely populated by small iceberg drifting over thousands of kilometers. The correlation between the global small and large icebergs volumes shows that small icebergs are mainly generated by large ones breaking. Drifting and trapping by sea ice can transport small icebergs for long period and distances. Small icebergs act as an ice diffuse process along large icebergs trajectories while sea ice trapping acts as a buffer delaying melting.

  11. 40 CFR 86.1838-01 - Small volume manufacturer certification procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... paragraph (c)(2). (i) Small volume in-use verification test vehicles may be procured from customers or may... miles, a manufacturer may demonstrate to the satisfaction of the Agency that, based on owner survey data...

  12. Structural changes in cross-border liabilities: A multidimensional approach

    NASA Astrophysics Data System (ADS)

    Araújo, Tanya; Spelta, Alessandro

    2014-01-01

    We study the international interbank market through a geometric analysis of empirical data. The geometric analysis of the time series of cross-country liabilities shows that the systematic information of the interbank international market is contained in a space of small dimension. Geometric spaces of financial relations across countries are developed, for which the space volume, multivariate skewness and multivariate kurtosis are computed. The behavior of these coefficients reveals an important modification acting in the financial linkages since 1997 and allows us to relate the shape of the geometric space that emerges in recent years to the globally turbulent period that has characterized financial systems since the late 1990s. Here we show that, besides a persistent decrease in the volume of the geometric space since 1997, the observation of a generalized increase in the values of the multivariate skewness and kurtosis sheds some light on the behavior of cross-border interdependencies during periods of financial crises. This was found to occur in such a systematic fashion, that these coefficients may be used as a proxy for systemic risk.

  13. Sizing protein-templated gold nanoclusters by time resolved fluorescence anisotropy decay measurements.

    PubMed

    Soleilhac, Antonin; Bertorelle, Franck; Antoine, Rodolphe

    2018-03-15

    Protein-templated gold nanoclusters (AuNCs) are very attractive due to their unique fluorescence properties. A major problem however may arise due to protein structure changes upon the nucleation of an AuNC within the protein for any future use as in vivo probes, for instance. In this work, we propose a simple and reliable fluorescence based technique measuring the hydrodynamic size of protein-templated gold nanoclusters. This technique uses the relation between the time resolved fluorescence anisotropy decay and the hydrodynamic volume, through the rotational correlation time. We determine the molecular size of protein-directed AuNCs, with protein templates of increasing sizes, e.g. insulin, lysozyme, and bovine serum albumin (BSA). The comparison of sizes obtained by other techniques (e.g. dynamic light scattering and small-angle X-ray scattering) between bare and gold clusters containing proteins allows us to address the volume changes induced either by conformational changes (for BSA) or the formation of protein dimers (for insulin and lysozyme) during cluster formation and incorporation. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Plasmonic Optical Fiber-Grating Immunosensing: A Review

    PubMed Central

    Loyez, Médéric; Caucheteur, Christophe

    2017-01-01

    Plasmonic immunosensors are usually made of a noble metal (in the form of a film or nanoparticles) on which bioreceptors are grafted to sense analytes based on the antibody/antigen or other affinity mechanism. Optical fiber configurations are a miniaturized counterpart to the bulky Kretschmann prism and allow easy light injection and remote operation. To excite a surface plasmon (SP), the core-guided light is locally outcoupled. Unclad optical fibers were the first configurations reported to this end. Among the different architectures able to bring light in contact with the surrounding medium, a great quantity of research is today being conducted on metal-coated fiber gratings photo-imprinted in the fiber core, as they provide modal features that enable SP generation at any wavelength, especially in the telecommunication window. They are perfectly suited for use with cost-effective high-resolution interrogators, allowing both a high sensitivity and a low limit of detection to be reached in immunosensing. This paper will review recent progress made in this field with different kinds of gratings: uniform, tilted and eccentric short-period gratings as well as long-period fiber gratings. Practical cases will be reported, showing that such sensors can be used in very small volumes of analytes and even possibly applied to in vivo diagnosis. PMID:29186871

  15. Computational tissue volume reconstruction of a peripheral nerve using high-resolution light-microscopy and reconstruct.

    PubMed

    Gierthmuehlen, Mortimer; Freiman, Thomas M; Haastert-Talini, Kirsten; Mueller, Alexandra; Kaminsky, Jan; Stieglitz, Thomas; Plachta, Dennis T T

    2013-01-01

    The development of neural cuff-electrodes requires several in vivo studies and revisions of the electrode design before the electrode is completely adapted to its target nerve. It is therefore favorable to simulate many of the steps involved in this process to reduce costs and animal testing. As the restoration of motor function is one of the most interesting applications of cuff-electrodes, the position and trajectories of myelinated fibers in the simulated nerve are important. In this paper, we investigate a method for building a precise neuroanatomical model of myelinated fibers in a peripheral nerve based on images obtained using high-resolution light microscopy. This anatomical model describes the first aim of our "Virtual workbench" project to establish a method for creating realistic neural simulation models based on image datasets. The imaging, processing, segmentation and technical limitations are described, and the steps involved in the transition into a simulation model are presented. The results showed that the position and trajectories of the myelinated axons were traced and virtualized using our technique, and small nerves could be reliably modeled based on of light microscopy images using low-cost OpenSource software and standard hardware. The anatomical model will be released to the scientific community.

  16. Computational Tissue Volume Reconstruction of a Peripheral Nerve Using High-Resolution Light-Microscopy and Reconstruct

    PubMed Central

    Gierthmuehlen, Mortimer; Freiman, Thomas M.; Haastert-Talini, Kirsten; Mueller, Alexandra; Kaminsky, Jan; Stieglitz, Thomas; Plachta, Dennis T. T.

    2013-01-01

    The development of neural cuff-electrodes requires several in vivo studies and revisions of the electrode design before the electrode is completely adapted to its target nerve. It is therefore favorable to simulate many of the steps involved in this process to reduce costs and animal testing. As the restoration of motor function is one of the most interesting applications of cuff-electrodes, the position and trajectories of myelinated fibers in the simulated nerve are important. In this paper, we investigate a method for building a precise neuroanatomical model of myelinated fibers in a peripheral nerve based on images obtained using high-resolution light microscopy. This anatomical model describes the first aim of our “Virtual workbench” project to establish a method for creating realistic neural simulation models based on image datasets. The imaging, processing, segmentation and technical limitations are described, and the steps involved in the transition into a simulation model are presented. The results showed that the position and trajectories of the myelinated axons were traced and virtualized using our technique, and small nerves could be reliably modeled based on of light microscopy images using low-cost OpenSource software and standard hardware. The anatomical model will be released to the scientific community. PMID:23785485

  17. Plasmonic Optical Fiber-Grating Immunosensing: A Review.

    PubMed

    Guo, Tuan; González-Vila, Álvaro; Loyez, Médéric; Caucheteur, Christophe

    2017-11-26

    Plasmonic immunosensors are usually made of a noble metal (in the form of a film or nanoparticles) on which bioreceptors are grafted to sense analytes based on the antibody/antigen or other affinity mechanism. Optical fiber configurations are a miniaturized counterpart to the bulky Kretschmann prism and allow easy light injection and remote operation. To excite a surface plasmon (SP), the core-guided light is locally outcoupled. Unclad optical fibers were the first configurations reported to this end. Among the different architectures able to bring light in contact with the surrounding medium, a great quantity of research is today being conducted on metal-coated fiber gratings photo-imprinted in the fiber core, as they provide modal features that enable SP generation at any wavelength, especially in the telecommunication window. They are perfectly suited for use with cost-effective high-resolution interrogators, allowing both a high sensitivity and a low limit of detection to be reached in immunosensing. This paper will review recent progress made in this field with different kinds of gratings: uniform, tilted and eccentric short-period gratings as well as long-period fiber gratings. Practical cases will be reported, showing that such sensors can be used in very small volumes of analytes and even possibly applied to in vivo diagnosis.

  18. Myosin light chain kinase and Src control membrane dynamics in volume recovery from cell swelling

    PubMed Central

    Barfod, Elisabeth T.; Moore, Ann L.; Van de Graaf, Benjamin G.; Lidofsky, Steven D.

    2011-01-01

     The expansion of the plasma membrane, which occurs during osmotic swelling of epithelia, must be retrieved for volume recovery, but the mechanisms are unknown. Here we have identified myosin light chain kinase (MLCK) as a regulator of membrane internalization in response to osmotic swelling in a model liver cell line. On hypotonic exposure, we found that there was time-dependent phosphorylation of the MLCK substrate myosin II regulatory light chain. At the sides of the cell, MLCK and myosin II localized to swelling-induced membrane blebs with actin just before retraction, and MLCK inhibition led to persistent blebbing and attenuated cell volume recovery. At the base of the cell, MLCK also localized to dynamic actin-coated rings and patches upon swelling, which were associated with uptake of the membrane marker FM4-64X, consistent with sites of membrane internalization. Hypotonic exposure evoked increased biochemical association of the cell volume regulator Src with MLCK and with the endocytosis regulators cortactin and dynamin, which colocalized within these structures. Inhibition of either Src or MLCK led to altered patch and ring lifetimes, consistent with the concept that Src and MLCK form a swelling-induced protein complex that regulates volume recovery through membrane turnover and compensatory endocytosis under osmotic stress. PMID:21209319

  19. 1. Keeper's house, small boathouse, and light tower, view east, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Keeper's house, small boathouse, and light tower, view east, west and south sides of keeper's house, west side of boathouse and tower - Great Duck Island Light Station, At southern tip of Great Duck Island southeast of Bass Harbor & northeast of Frenchboro, Frenchboro, Hancock County, ME

  20. Light extinction method on high-pressure diesel injection

    NASA Astrophysics Data System (ADS)

    Su, Tzay-Fa; El-Beshbeeshy, Mahmound S.; Corradini, Michael L.; Farrell, Patrick V.

    1995-09-01

    A two dimensional optical diagnostic technique based on light extinction was improved and demonstrated in an investigation of diesel spray characteristics at high injection pressures. Traditional light extinction methods require the spray image to be perpendicular to the light path. In the improved light extinction scheme, a tilted spray image which has an angle with the light path is still capable of being processed. This technique utilizes high speed photography and digital image analysis to obtain qualitative and quantitative information of the spray characteristics. The injection system used was an electronically controlled common rail unit injector system with injection pressures up to 100 MPa. The nozzle of the injector was a mini-sac type with six holes on the nozzle tip. Two different injection angle nozzles, 125 degree(s) and 140 degree(s), producing an in-plane tilted spray and an out of plane tilted spray were investigated. The experiments were conducted on a constant volume spray chamber with the injector mounted tilted at an angle of 62.5 degree(s)$. Only one spray plume was viewed, and other sprays were free to inject to the chamber. The spray chamber was pressurized with argon and air under room temperature to match the combustion chamber density at the start of the injection. The experimental results show that the difference in the spray tip penetration length, spray angle, and overall average Sauter mean diameter is small between the in- plane tilted spray and the out of plane tilted spray. The results also show that in-plane tilted spray has a slightly larger axial cross- section Sauter mean diameter than the out of plane tilted spray.

  1. Plant Atrium System for Food Production in NASA's Deep Space Habitat Tests

    NASA Technical Reports Server (NTRS)

    Massa, Gioia D.; Simpson, Morgan; Wheeler, Raymond M.; Newsham, Gerald; Stutte, Gary W.

    2013-01-01

    In preparation for future human exploration missions to space, NASA evaluates habitat concepts to assess integration issues, power requirements, crew operations, technology, and system performance. The concept of a Food Production System utilizes fresh foods, such as vegetables and small fruits, harvested on a continuous basis, to improve the crew's diet and quality of life. The system would need to fit conveniently into the habitat and not interfere with other components or operations. To test this concept, a plant growing "atrium" was designed to surround the lift between the lower and upper modules of the Deep Space Habitat and deployed at NASA Desert Research and Technology Studies (DRATS) test site in 2011 and at NASA Johnson Space Center in 2012. With this approach, no-utilized volume provided an area for vegetable growth. For the 2011 test, mizuna, lettuce, basil, radish and sweetpotato plants were grown in trays using commercially available red I blue LED light fixtures. Seedlings were transplanted into the atrium and cared for by the. crew. Plants were then harvested two weeks later following completion of the test. In 2012, mizuna, lettuce, and radish plants were grown similarly but under flat panel banks of white LEDs. In 2012, the crew went through plant harvesting, including sanitizing tlie leafy greens and radishes, which were then consumed. Each test demonstrated successful production of vegetables within a functional hab module. The round red I blue LEDs for the 2011 test lighting cast a purple light in the hab, and were less uniformly distributed over the plant trays. The white LED panels provided broad spectrum light with more uniform distribution. Post-test questionnaires showed that the crew enjoyed tending and consuming the plants and that the white LED light in 2012 provided welcome extra light for the main HAB AREA.

  2. Engineering photonic and plasmonic light emission enhancement

    NASA Astrophysics Data System (ADS)

    Lawrence, Nathaniel

    Semiconductor photonic devices are a rapidly maturing technology which currently occupy multi-billion dollar markets in the areas of LED lighting and optical data communication. LEDs currently demonstrate the highest luminous efficiency of any light source for general lighting. Long-haul optical data communication currently forms the backbone of the global communication network. Proper design of light management is required for photonic devices, which can increase the overall efficiency or add new device functionality. In this thesis, novel methods for the control of light propagation and confinement are developed for the use in integrated photonic devices. The first part of this work focuses on the engineering of field confinement within deep subwavelength plasmonic resonators for the enhancement of light-matter interaction. In this section, plasmonic ring nanocavities are shown to form gap plasmon modes confined to the dielectric region between two metal layers. The scattering properties, near-field enhancement and photonic density of states of nanocavity devices are studied using analytic theory and 3D finite difference time domain simulations. Plasmonic ring nanocavities are fabricated and characterized using photoluminescence intensity and decay rate measurements. A 25 times increase in the radiative decay rate of Er:Si02 is demonstrated in nanocavities where light is confined to volumes as small as 0.01( ln )3. The potential to achieve lasing, due to the enhancement of stimulated emission rate in ring nanocavities, is studied as a route to Si-compatible plasmon-enhanced nanolasers. The second part of this work focuses on the manipulation of light generated in planar semiconductor devices using arrays of dielectric nanopillars. In particular, aperiodic arrays of nanopillars are engineered for omnidirectional light extraction enhancement. Arrays of Er:SiNx, nanopillars are fabricated and a ten times increase in light extraction is experimentally demonstrated, while simultaneously controlling far-field radiation patterns in ways not possible with periodic arrays. Additionally, analytical scalar diffraction theory is used to study light propagation from Vogel spiral arrays and demonstrate generation of OAM. Using phase shifting interferometry, the presence of OAM is experimentally verified. The use of Vogel spirals presents a new method for the generation of OAM with applications for secure optical communications.

  3. Sensitive Small Area Photometer

    ERIC Educational Resources Information Center

    Levenson, M. D.

    1970-01-01

    Describes a simple photometer capable of measuring small light intensities over small areas. The inexpensive, easy-to- construct instrument is intended for use in a student laboratory to measure the light intensities in a diffraction experiment from single or multiple slits. Typical experimental results are presented along with the theoretical…

  4. Development of a PEMFC Power System with Integrated Balance of Plant

    NASA Technical Reports Server (NTRS)

    Wynne, B.; Diffenderfer, C.; Ferguson, S.; Keyser, J.; Miller, M.; Sievers, B.; Ryan, A.; Vasquez, A.

    2012-01-01

    Autonomous Underwater Vehicles (AUV s) have received increasing attention in recent years as military and commercial users look for means to maintain a mobile and persistent presence in the undersea world. Compact, neutrally buoyant power systems are needed for both small and large vehicles. Batteries are usually employed in these applications, but the energy density and therefore the mission duration are limited with current battery technology. At a certain energy or mission duration requirement, other means to get long duration power become feasible. For example, above 10 kW-hrs liquid oxygen and hydrogen have better specific energy than batteries and are preferable for energy storage as long as a compact system of about 100 W/liter is achievable to convert the chemical energy in these reactants into power. Other reactant forms are possible, such as high pressure gas, chemical hydrides or oxygen carriers, but it is essential that the power system be small and light weight. Recent fuel cell work, primarily focused on NASA applications, has developed power systems that can meet this target power density. Passive flow-through systems, using ejector driven reactant (EDR) flow, integrated into a compact balance of plant have been developed. These systems are thermally and functionally integrated in much the same way as are automotive, air breathing fuel cell systems. These systems fit into the small volumes required for AUV and future NASA applications. Designs have been developed for both a 21" diameter and a larger diameter (LD) AUV. These fuel cell systems occupy a very small portion of the overall energy system, allowing most of the system volume to be used for the reactants. The fuel cell systems have been optimized to use reactants efficiently with high stack efficiency and low parasitic losses. The resulting compact, highly efficient fuel cell system provides exceptional reactant utilization and energy density. Key design variables and supporting test data are presented. Future development activities are described.

  5. Impact of Polarizing Non-Lambertian Surface and Volume Scattering on Polarized Light Signatures: Importance to Remote Sensing

    DTIC Science & Technology

    2016-12-08

    RVIL Kirtland AFB, NM 87117-5776 Official Record Copy AFRL /RVBYI/Jeannette van den Bosch 1 cy Approved for public release; distribution is... AFRL -RV-PS- TR-2017-0156 AFRL -RV-PS- TR-2017-0156 IMPACT OF POLARIZING NON-LAMBERTIAN SURFACE AND VOLUME SCATTERING ON POLARIZED LIGHT...3550 Aberdeen Ave SE AIR FORCE MATERIEL COMMAND KIRTLAND AIR FORCE BASE, NM 87117-5776 DTIC COPY NOTICE AND SIGNATURE PAGE Using Government

  6. Ignition and combustion characteristics of metallized propellants

    NASA Technical Reports Server (NTRS)

    Turns, S. R.; Mueller, D. C.; Scott, M. J.

    1990-01-01

    Research designed to develop detailed knowledge of the secondary atomization and ignition characteristics of aluminum slurry propellants was started. These processes are studied because they are the controlling factors limiting the combustion efficiency of aluminum slurry propellants in rocket applications. A burner and spray rig system allowing the study of individual slurry droplets having diameters from about 10 to 100 microns was designed and fabricated. The burner generates a near uniform high temperature environment from the merging of 72 small laminar diffusion flames above a honeycomb matrix. This design permits essentially adiabatic operation over a wide range of stoichiometries without danger of flashback. A single particle sizing system and velocimeter also were designed and assembled. Light scattered from a focused laser beam is related to the particle (droplet) size, while the particle velocity is determined by its transit time through the focal volume. Light from the combustion of aluminum is also sensed to determine if ignition was achieved. These size and velocity measurements will allow the determination of disruption and ignition times as functions of drop sizes and ambient conditions.

  7. Ar-40/Ar-39 Ages of Maskelynite Grains from ALHA 77005

    NASA Technical Reports Server (NTRS)

    Turrin, B.; Park, J.; Herzog, G. F.; Lindsay, F. N.; Delaney, J. S.; Nyquist, L. E.; Swisher, C., III

    2013-01-01

    We present Ar-40/Ar-39 measurements for twelve small (20-60 micro-g) maskelynite samples from the heavily shocked martian meteorite ALHA 77005. The reported modal composition for ALHA 77005 is 50-60% olivine (Fa28), 30-40% pyroxene (Wo5Fs23En72), approx.8% maskelynite (An53), and approx.2% opaques by volume [1]). The meteorite is usually classified as a lherzolite. Previous Studies - Ar-40/Ar-39 results from previous work display disturbed release spectra [2,3]. In study [2], Ar-40/Ar-39 measurements on a 52-mg whole-rock sample produced an extremely disturbed release spec-trum, with all calculated apparent ages > 1 Ga, (Fig. 1). In a subsequent study [3], a light and a dark phase were analyzed. A 2.3-mg sample of the light, relatively low-K phase produced a disturbed release spectrum. For the first 20% of the Ar-39(sub K), most of the apparent ages exceeded >1 Ga; the remaining 80% yielded ages between 0.3-0.5 Ga. The integrated age for this phase is 0.9 Ga.

  8. A nearly on-axis spectroscopic system for simultaneously measuring UV-visible absorption and X-ray diffraction in the SPring-8 structural genomics beamline.

    PubMed

    Sakaguchi, Miyuki; Kimura, Tetsunari; Nishida, Takuma; Tosha, Takehiko; Sugimoto, Hiroshi; Yamaguchi, Yoshihiro; Yanagisawa, Sachiko; Ueno, Go; Murakami, Hironori; Ago, Hideo; Yamamoto, Masaki; Ogura, Takashi; Shiro, Yoshitsugu; Kubo, Minoru

    2016-01-01

    UV-visible absorption spectroscopy is useful for probing the electronic and structural changes of protein active sites, and thus the on-line combination of X-ray diffraction and spectroscopic analysis is increasingly being applied. Herein, a novel absorption spectrometer was developed at SPring-8 BL26B2 with a nearly on-axis geometry between the X-ray and optical axes. A small prism mirror was placed near the X-ray beamstop to pass the light only 2° off the X-ray beam, enabling spectroscopic analysis of the X-ray-exposed volume of a crystal during X-ray diffraction data collection. The spectrometer was applied to NO reductase, a heme enzyme that catalyzes NO reduction to N2O. Radiation damage to the heme was monitored in real time during X-ray irradiation by evaluating the absorption spectral changes. Moreover, NO binding to the heme was probed via caged NO photolysis with UV light, demonstrating the extended capability of the spectrometer for intermediate analysis.

  9. Dark Energy and Dark Matter as w = -1 Virtual Particles and the World Hologram Model

    NASA Astrophysics Data System (ADS)

    Sarfatti, Jack

    2011-04-01

    The elementary physics battle-tested principles of Lorentz invariance, Einstein equivalence principle and the boson commutation and fermion anti-commutation rules of quantum field theory explain gravitationally repulsive dark energy as virtual bosons and gravitationally attractive dark matter as virtual fermion-antifermion pairs. The small dark energy density in our past light cone is the reciprocal entropy-area of our future light cone's 2D future event horizon in a Novikov consistent loop in time in our accelerating universe. Yakir Aharonov's "back-from-the-future" post-selected final boundary condition is set at our observer-dependent future horizon that also explains why the irreversible thermodynamic arrow of time of is aligned with the accelerating dark energy expansion of the bulk 3D space interior to our future 2D horizon surrounding it as the hologram screen. Seth Lloyd has argued that all 2D horizon surrounding surfaces are pixelated quantum computers projecting interior bulk 3D quanta of volume (Planck area)Sqrt(area of future horizon) as their hologram images in 1-1 correspondence.

  10. The Different Volume Effects of Small-Bowel Toxicity During Pelvic Irradiation Between Gynecologic Patients With and Without Abdominal Surgery: A Prospective Study With Computed Tomography-Based Dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, E.-Y.; Graduate Institute of Clinical Medical Sciences, Chang Gung University College of Medicine, Kaohsiung, Taiwan; School of Traditional Chinese Medicine, Chang Gung University College of Medicine, Kaohsiung, Taiwan

    Purpose: To evaluate the effect of abdominal surgery on the volume effects of small-bowel toxicity during whole-pelvic irradiation in patients with gynecologic malignancies. Methods and Materials: From May 2003 through November 2006, 80 gynecologic patients without (Group I) or with (Group II) prior abdominal surgery were analyzed. We used a computed tomography (CT) planning system to measure the small-bowel volume and dosimetry. We acquired the range of small-bowel volume in 10% (V10) to 100% (V100) of dose, at 10% intervals. The onset and grade of diarrhea during whole-pelvic irradiation were recorded as small-bowel toxicity up to 39.6 Gy in 22more » fractions. Results: The volume effect of Grade 2-3 diarrhea existed from V10 to V100 in Group I patients and from V60 to V100 in Group II patients on univariate analyses. The V40 of Group I and the V100 of Group II achieved most statistical significance. The mean V40 was 281 {+-} 27 cm{sup 3} and 489 {+-} 34 cm{sup 3} (p < 0.001) in Group I patients with Grade 0-1 and Grade 2-3 diarrhea, respectively. The corresponding mean V100 of Group II patients was 56 {+-} 14 cm{sup 3} and 132 {+-} 19 cm{sup 3} (p = 0.003). Multivariate analyses revealed that V40 (p = 0.001) and V100 (p = 0.027) were independent factors for the development of Grade 2-3 diarrhea in Groups I and II, respectively. Conclusions: Gynecologic patients without and with abdominal surgery have different volume effects on small-bowel toxicity during whole-pelvic irradiation. Low-dose volume can be used as a predictive index of Grade 2 or greater diarrhea in patients without abdominal surgery. Full-dose volume is more important than low-dose volume for Grade 2 or greater diarrhea in patients with abdominal surgery.« less

  11. Measuring pedestrian volumes and conflicts. Volume 1, Pedestrian volume sampling

    DOT National Transportation Integrated Search

    1987-12-01

    This final report presents the findings, conclusions, and recommendations of the study conducted to develop a model to predict pedestrian volumes using small sampling schemes. This research produced four pedestrian volume prediction models (i.e., 1-,...

  12. [Effects of forest gap size and light intensity on herbaceous plants in Pinus koraiensis-dominated broadleaved mixed forest].

    PubMed

    Duan, Wen-Biao; Wang, Li-Xia; Chen, Li-Xin; Du, Shan; Wei, Quan-Shuai; Zhao, Jian-Hui

    2013-03-01

    1 m x 1 m fixed quadrats were parallelly arranged with a space of 2 m in each of six forest gaps in Pinus koraiensis-dominated broadleaved mixed forest, taking the gap center as the starting point and along east-west and south-north directions. In each quadrat, the coverage and abundance of herbaceous plants at different height levels were investigated by estimation method in June and September 2011, and the matrix characteristics within the quadrats were recorded. Canopy analyzer was used to take fish-eye photos in the selected overcast days in each month from June to September, 2011, and the relative light intensity was calculated by using Gap Light Analyzer 2.0 software. The differences in the relative light intensity and herbaceous plants coverage and richness between different gaps as well as the correlations between the coverage of each species and the direct light, diffuse light, and matrix were analyzed. The results showed that in opening areas and under canopy, the relative light intensity in large gaps was higher than that in small gaps, and the variation ranges of diffuse light and direct light from gap center to gap edge were bigger in large gaps than in small gaps. The direct light reaching at the ground both in large gaps and in small gaps was higher in the north than in the south direction. In the Z1, Z2, Z3, and Z4 zones, both the coverage and the richness of herbaceous plants were larger in large gaps than in small gaps, and the differences of species richness between large and small gaps reached significant level. The coverage of the majority of the herbaceous plants had significant correlations with diffuse light and matrix, and only the coverage of a few herbaceous plants was correlated with direct light.

  13. Mechanistic Fluid Transport Model to Estimate Gastrointestinal Fluid Volume and Its Dynamic Change Over Time.

    PubMed

    Yu, Alex; Jackson, Trachette; Tsume, Yasuhiro; Koenigsknecht, Mark; Wysocki, Jeffrey; Marciani, Luca; Amidon, Gordon L; Frances, Ann; Baker, Jason R; Hasler, William; Wen, Bo; Pai, Amit; Sun, Duxin

    2017-11-01

    Gastrointestinal (GI) fluid volume and its dynamic change are integral to study drug disintegration, dissolution, transit, and absorption. However, key questions regarding the local volume and its absorption, secretion, and transit remain unanswered. The dynamic fluid compartment absorption and transit (DFCAT) model is proposed to estimate in vivo GI volume and GI fluid transport based on magnetic resonance imaging (MRI) quantified fluid volume. The model was validated using GI local concentration of phenol red in human GI tract, which was directly measured by human GI intubation study after oral dosing of non-absorbable phenol red. The measured local GI concentration of phenol red ranged from 0.05 to 168 μg/mL (stomach), to 563 μg/mL (duodenum), to 202 μg/mL (proximal jejunum), and to 478 μg/mL (distal jejunum). The DFCAT model characterized observed MRI fluid volume and its dynamic changes from 275 to 46.5 mL in stomach (from 0 to 30 min) with mucus layer volume of 40 mL. The volumes of the 30 small intestine compartments were characterized by a max of 14.98 mL to a min of 0.26 mL (0-120 min) and a mucus layer volume of 5 mL per compartment. Regional fluid volumes over 0 to 120 min ranged from 5.6 to 20.38 mL in the proximal small intestine, 36.4 to 44.08 mL in distal small intestine, and from 42 to 64.46 mL in total small intestine. The DFCAT model can be applied to predict drug dissolution and absorption in the human GI tract with future improvements.

  14. “Modular Biospheres” New testbed platforms for public environmental education and research

    NASA Astrophysics Data System (ADS)

    Nelson, M.; Dempster, W. F.; Allen, J. P.

    This paper will review the potential of a relatively new type of testbed platform for environmental education and research because of the unique advantages resulting from their material closure and separation from the outside environment. These facilities which we term "modular biospheres", have emerged from research centered on space life support research but offer a wider range of application. Examples of this type of facility include the Bios-3 facility in Russia, the Japanese CEEF (Closed Ecological Experiment Facility), the NASA Kennedy Space Center Breadboard facility, the Biosphere 2 Test Module and the Laboratory Biosphere. Modular biosphere facilities offer unique research and public real-time science education opportunities. Ecosystem behavior can be studied since initial state conditions can be precisely specified and tracked over different ranges of time. With material closure (apart from very small air exchange rate which can be determined), biogeochemical cycles between soil and soil microorganisms, water, plants, and atmosphere can be studied in detail. Such studies offer a major advance from studies conducted with phytotrons which because of their small size, limit the number of organisms to a very small number, and which crucially do not have a high degree of atmospheric, water and overall material closure. Modular biospheres take advantage of the unique properties of closure, as representing a distinct system "metabolism" and therefore are essentially a "mini-world". Though relatively large in comparison with most phytotrons and ecological microcosms, which are now standard research and educational tools, modular biospheres are small enough that they can be economically reconfigured to reflect a changing research agenda. Some design elements include lighting via electric lights and/or sunlight, hydroponic or soil substrate for plants, opaque or glazed structures, and variable volume chambers or other methods to handle atmospheric pressure differences between the facility and the outside environment.

  15. 75 FR 73073 - Washington Gas Light Company; Notice of Filing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-29

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR11-74-000] Washington Gas Light Company; Notice of Filing November 18, 2010. Take notice that on November 15, 2010, Washington Gas Light Company (Washington Gas) filed its annual actual lost and unaccounted for volumes (LAUF...

  16. Physics of Hard Spheres Experiment: Significant and Quantitative Findings Made

    NASA Technical Reports Server (NTRS)

    Doherty, Michael P.

    2000-01-01

    Direct examination of atomic interactions is difficult. One powerful approach to visualizing atomic interactions is to study near-index-matched colloidal dispersions of microscopic plastic spheres, which can be probed by visible light. Such spheres interact through hydrodynamic and Brownian forces, but they feel no direct force before an infinite repulsion at contact. Through the microgravity flight of the Physics of Hard Spheres Experiment (PHaSE), researchers have sought a more complete understanding of the entropically driven disorder-order transition in hard-sphere colloidal dispersions. The experiment was conceived by Professors Paul M. Chaikin and William B. Russel of Princeton University. Microgravity was required because, on Earth, index-matched colloidal dispersions often cannot be density matched, resulting in significant settling over the crystallization period. This settling makes them a poor model of the equilibrium atomic system, where the effect of gravity is truly negligible. For this purpose, a customized light-scattering instrument was designed, built, and flown by the NASA Glenn Research Center at Lewis Field on the space shuttle (shuttle missions STS 83 and STS 94). This instrument performed both static and dynamic light scattering, with sample oscillation for determining rheological properties. Scattered light from a 532- nm laser was recorded either by a 10-bit charge-coupled discharge (CCD) camera from a concentric screen covering angles of 0 to 60 or by sensitive avalanche photodiode detectors, which convert the photons into binary data from which two correlators compute autocorrelation functions. The sample cell was driven by a direct-current servomotor to allow sinusoidal oscillation for the measurement of rheological properties. Significant microgravity research findings include the observation of beautiful dendritic crystals, the crystallization of a "glassy phase" sample in microgravity that did not crystallize for over 1 year in 1g (Earth's gravity), and the emergence of face-centered-cubic (FCC) crystals late in the coarsening process (as small crystallites lost particles to the slow ripening of large crystallites). Significant quantitative findings from the microgravity experiments have been developed describing complex interactions among crystallites during the growth process, as concentration fields overlap in the surrounding disordered phase. Time-resolved Bragg scattering under microgravity captures one effect of these interactions quite conclusively for the sample at a volume fraction of 0.528. From the earliest time until the sample is almost fully crystalline, the size and overall crystallinity grow monotonically, but the number of crystallites per unit volume (number density) falls. Apparently nucleation is slower than the loss of crystallites because of the transfer of particles from small to large crystals. Thus, coarsening occurs simultaneously with growth, rather than following the completion of nucleation and growth as is generally assumed. In the same sample, an interesting signature appears in the apparent number density of crystallites and the volume fraction within the crystallites shortly before full crystallinity is reached. A brief upturn in both indicates the creation of more domains of the size of the average crystallite simultaneous with the compression of the crystallites. Only the emergence of dendritic arms offers a reasonable explanation. The arms would be "seen" by the light scattering as separate domains whose smaller radii of curvature would compress the interior phase. In fiscal year 1999, numerous papers, a doctoral dissertation, and the PHaSE final report were produced. Although this flight project has been completed, plans are in place for a follow-on colloid experiment by Chaikin and Russel that employs a light microscope within Glenn's Fluids and Combustion Facility on the International Space Station. PHaSE is providing us with a deeper understanding of the nure of phase transitions. The knowledge derived has added to the understanding of condensed matter. In addition, the burgeoning study of the dynamics of colloidal self-assembly may lead to the development of a range of photonic materials that control the desirable properties of light. Thus, applications of ordered colloidal structures include not only ultrastructure ceramics, but also photonic crystals and photothermal nanosecond light-switching devices. Industries dealing with semiconductors, electro-optics, ceramics, and composites stand to benefit from such advancements.

  17. 3D reconstruction of carbon nanotube networks from neutron scattering experiments

    DOE PAGES

    Mahdavi, Mostafa; Baniassadi, Majid; Baghani, Mostafa; ...

    2015-09-03

    Structure reconstruction from statistical descriptors, such as scattering data obtained using x-rays or neutrons, is essential in understanding various properties of nanocomposites. Scattering based reconstruction can provide a realistic model, over various length scales, that can be used for numerical simulations. In this study, 3D reconstruction of a highly loaded carbon nanotube (CNT)-conducting polymer system based on small and ultra-small angle neutron scattering (SANS and USANS, respectively) data was performed. These light-weight and flexible materials have recently shown great promise for high-performance thermoelectric energy conversion, and their further improvement requires a thorough understanding of their structure-property relationships. The first stepmore » in achieving such understanding is to generate models that contain the hierarchy of CNT networks over nano and micron scales. The studied system is a single walled carbon nanotube (SWCNT)/poly (3,4-ethylenedioxythiophene): poly (styrene sulfonate) (PEDOT: PSS). SANS and USANS patterns of the different samples containing 10, 30, and 50 wt% SWCNTs were measured. These curves were then utilized to calculate statistical two-point correlation functions of the nanostructure. These functions along with the geometrical information extracted from SANS data and scanning electron microscopy images were used to reconstruct a representative volume element (RVE) nanostructure. Generated RVEs can be used for simulations of various mechanical and physical properties. This work, therefore, introduces a framework for the reconstruction of 3D RVEs of high volume faction nanocomposites containing high aspect ratio fillers from scattering experiments.« less

  18. 3D reconstruction of carbon nanotube networks from neutron scattering experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mahdavi, Mostafa; Baniassadi, Majid; Baghani, Mostafa

    Structure reconstruction from statistical descriptors, such as scattering data obtained using x-rays or neutrons, is essential in understanding various properties of nanocomposites. Scattering based reconstruction can provide a realistic model, over various length scales, that can be used for numerical simulations. In this study, 3D reconstruction of a highly loaded carbon nanotube (CNT)-conducting polymer system based on small and ultra-small angle neutron scattering (SANS and USANS, respectively) data was performed. These light-weight and flexible materials have recently shown great promise for high-performance thermoelectric energy conversion, and their further improvement requires a thorough understanding of their structure-property relationships. The first stepmore » in achieving such understanding is to generate models that contain the hierarchy of CNT networks over nano and micron scales. The studied system is a single walled carbon nanotube (SWCNT)/poly (3,4-ethylenedioxythiophene): poly (styrene sulfonate) (PEDOT: PSS). SANS and USANS patterns of the different samples containing 10, 30, and 50 wt% SWCNTs were measured. These curves were then utilized to calculate statistical two-point correlation functions of the nanostructure. These functions along with the geometrical information extracted from SANS data and scanning electron microscopy images were used to reconstruct a representative volume element (RVE) nanostructure. Generated RVEs can be used for simulations of various mechanical and physical properties. This work, therefore, introduces a framework for the reconstruction of 3D RVEs of high volume faction nanocomposites containing high aspect ratio fillers from scattering experiments.« less

  19. Large volume flow-through scintillating detector

    DOEpatents

    Gritzo, Russ E.; Fowler, Malcolm M.

    1995-01-01

    A large volume flow through radiation detector for use in large air flow situations such as incinerator stacks or building air systems comprises a plurality of flat plates made of a scintillating material arranged parallel to the air flow. Each scintillating plate has a light guide attached which transfers light generated inside the scintillating plate to an associated photomultiplier tube. The output of the photomultiplier tubes are connected to electronics which can record any radiation and provide an alarm if appropriate for the application.

  20. Influence of carbon nanoparticle modification on the mechanical and electrical properties of epoxy in small volumes.

    PubMed

    Leopold, Christian; Augustin, Till; Schwebler, Thomas; Lehmann, Jonas; Liebig, Wilfried V; Fiedler, Bodo

    2017-11-15

    The influence of nanoparticle morphology and filler content on the mechanical and electrical properties of carbon nanoparticle modified epoxy is investigated regarding small volumes. Three types of particles, representing spherical, tubular and layered morphologies are used. A clear size effect of increasing true failure strength with decreasing volume is found for neat and carbon black modified epoxy. Carbon nanotube (CNT) modified epoxy exhibits high potential for strength increase, but dispersion and purity are critical. In few layer graphene modified epoxy, particles are larger than statistically distributed defects and initiate cracks, counteracting any size effect. Different toughness increasing mechanisms on the nano- and micro-scale depending on particle morphology are discussed based on scanning electron microscopy images. Electrical percolation thresholds in the small volume fibres are significantly higher compared to bulk volume, with CNT being found to be the most suitable morphology to form electrical conductive paths. Good correlation between electrical resistance change and stress strain behaviour under tensile loads is observed. The results show the possibility to detect internal damage in small volumes by measuring electrical resistance and therefore indicate to the high potential for using CNT modified polymers in fibre reinforced plastics as a multifunctional, self-monitoring material with improved mechanical properties. Copyright © 2017. Published by Elsevier Inc.

  1. Polymer and small molecule based hybrid light source

    DOEpatents

    Choong, Vi-En; Choulis, Stelios; Krummacher, Benjamin Claus; Mathai, Mathew; So, Franky

    2010-03-16

    An organic electroluminescent device, includes: a substrate; a hole-injecting electrode (anode) coated over the substrate; a hole injection layer coated over the anode; a hole transporting layer coated over the hole injection layer; a polymer based light emitting layer, coated over the hole transporting layer; a small molecule based light emitting layer, thermally evaporated over the polymer based light emitting layer; and an electron-injecting electrode (cathode) deposited over the electroluminescent polymer layer.

  2. Effective phase function of light scattered at small angles by polydisperse particulate media

    NASA Astrophysics Data System (ADS)

    Turcu, I.

    2008-06-01

    Particles with typical dimensions higher than the light wavelength and relative refraction indexes close to one, scatter light mainly in the forward direction where the scattered light intensity has a narrow peak. For particulate media accomplishing these requirements the light scattered at small angles in a far-field detecting set-up can be described analytically by an effective phase function (EPF) even in the multiple scattering regime. The EPF model which was built for monodispersed systems has been extended to polydispersed media. The main ingredients consist in the replacement of the single particle phase function and of the optical thickness with their corresponding averaged values. Using a Gamma particle size distribution (PSD) as a testing model, the effect of polydispersity was systematically investigated. The increase of the average radius or/and of the PSD standard deviation leads to the decrease of the angular spreading of the small angle scattered light.

  3. Study of CCT varying by volume scattering diffuser with moving and rotating white light LED

    NASA Astrophysics Data System (ADS)

    Ma, Shih-Hsin; Chen, Liang-Shiun; Huang, Wen-Chao

    2014-09-01

    In this study, the corrected color temperature (CCT) of white light, which originates from a white light LED (WLLED) and passes through a volume-scattering diffuser (VSD), is investigated. The VSD with thickness of 2mm is fabricated by mixing the 2um-sized PMMA scattering particles and the epoxy glue with different concentration values. Moreover, in order to understand the influences of the illuminated area and the scattering path of VSD on CCT values, the bulletheaded and lambertian-type WLLEDs are assembled for different positions and distinct orientations along the optical axis in a black cavity. A detailed comparison between results regarding the white light with and without passing through the VSD is offered. The results of this research will help to improve the colorful consistency of the LED lamps which use diffusers.

  4. Small-volume amnioinfusion: a potential stimulus of intrapartum fetal heart rate accelerations.

    PubMed

    Wax, Joseph R; Flaherty, Nina; Pinette, Michael G; Blackstone, Jacquelyn; Cartin, Angelina

    2004-02-01

    We describe a recurrent nonreassuring fetal heart rate pattern in which small-volume amnioinfusions apparently evoked fetal heart rate accelerations suggested fetal well-being, allowing that progressive labor that culminated in the vaginal delivery of a healthy infant.

  5. Small-Volume Injections: Evaluation of Volume Administration Deviation From Intended Injection Volumes.

    PubMed

    Muffly, Matthew K; Chen, Michael I; Claure, Rebecca E; Drover, David R; Efron, Bradley; Fitch, William L; Hammer, Gregory B

    2017-10-01

    In the perioperative period, anesthesiologists and postanesthesia care unit (PACU) nurses routinely prepare and administer small-volume IV injections, yet the accuracy of delivered medication volumes in this setting has not been described. In this ex vivo study, we sought to characterize the degree to which small-volume injections (≤0.5 mL) deviated from the intended injection volumes among a group of pediatric anesthesiologists and pediatric postanesthesia care unit (PACU) nurses. We hypothesized that as the intended injection volumes decreased, the deviation from those intended injection volumes would increase. Ten attending pediatric anesthesiologists and 10 pediatric PACU nurses each performed a series of 10 injections into a simulated patient IV setup. Practitioners used separate 1-mL tuberculin syringes with removable 18-gauge needles (Becton-Dickinson & Company, Franklin Lakes, NJ) to aspirate 5 different volumes (0.025, 0.05, 0.1, 0.25, and 0.5 mL) of 0.25 mM Lucifer Yellow (LY) fluorescent dye constituted in saline (Sigma Aldrich, St. Louis, MO) from a rubber-stoppered vial. Each participant then injected the specified volume of LY fluorescent dye via a 3-way stopcock into IV tubing with free-flowing 0.9% sodium chloride (10 mL/min). The injected volume of LY fluorescent dye and 0.9% sodium chloride then drained into a collection vial for laboratory analysis. Microplate fluorescence wavelength detection (Infinite M1000; Tecan, Mannedorf, Switzerland) was used to measure the fluorescence of the collected fluid. Administered injection volumes were calculated based on the fluorescence of the collected fluid using a calibration curve of known LY volumes and associated fluorescence.To determine whether deviation of the administered volumes from the intended injection volumes increased at lower injection volumes, we compared the proportional injection volume error (loge [administered volume/intended volume]) for each of the 5 injection volumes using a linear regression model. Analysis of variance was used to determine whether the absolute log proportional error differed by the intended injection volume. Interindividual and intraindividual deviation from the intended injection volume was also characterized. As the intended injection volumes decreased, the absolute log proportional injection volume error increased (analysis of variance, P < .0018). The exploratory analysis revealed no significant difference in the standard deviations of the log proportional errors for injection volumes between physicians and pediatric PACU nurses; however, the difference in absolute bias was significantly higher for nurses with a 2-sided significance of P = .03. Clinically significant dose variation occurs when injecting volumes ≤0.5 mL. Administering small volumes of medications may result in unintended medication administration errors.

  6. Integrated one- and two-photon scanned oblique plane illumination (SOPi) microscopy for rapid volumetric imaging

    NASA Astrophysics Data System (ADS)

    Kumar, Manish; Kishore, Sandeep; Nasenbeny, Jordan; McLean, David L.; Kozorovitskiy, Yevgenia

    2018-05-01

    Versatile, sterically accessible imaging systems capable of in vivo rapid volumetric functional and structural imaging deep in the brain continue to be a limiting factor in neuroscience research. Towards overcoming this obstacle, we present integrated one- and two-photon scanned oblique plane illumination (SOPi) microscopy which uses a single front-facing microscope objective to provide light-sheet scanning based rapid volumetric imaging capability at subcellular resolution. Our planar scan-mirror based optimized light-sheet architecture allows for non-distorted scanning of volume samples, simplifying accurate reconstruction of the imaged volume. Integration of both one-photon (1P) and two-photon (2P) light-sheet microscopy in the same system allows for easy selection between rapid volumetric imaging and higher resolution imaging in scattering media. Using SOPi, we demonstrate deep, large volume imaging capability inside scattering mouse brain sections and rapid imaging speeds up to 10 volumes per second in zebrafish larvae expressing genetically encoded fluorescent proteins GFP or GCaMP6s. SOPi flexibility and steric access makes it adaptable for numerous imaging applications and broadly compatible with orthogonal techniques for actuating or interrogating neuronal structure and activity.

  7. Integrated one- and two-photon scanned oblique plane illumination (SOPi) microscopy for rapid volumetric imaging.

    PubMed

    Kumar, Manish; Kishore, Sandeep; Nasenbeny, Jordan; McLean, David L; Kozorovitskiy, Yevgenia

    2018-05-14

    Versatile, sterically accessible imaging systems capable of in vivo rapid volumetric functional and structural imaging deep in the brain continue to be a limiting factor in neuroscience research. Towards overcoming this obstacle, we present integrated one- and two-photon scanned oblique plane illumination (SOPi, /sōpī/) microscopy which uses a single front-facing microscope objective to provide light-sheet scanning based rapid volumetric imaging capability at subcellular resolution. Our planar scan-mirror based optimized light-sheet architecture allows for non-distorted scanning of volume samples, simplifying accurate reconstruction of the imaged volume. Integration of both one-photon (1P) and two-photon (2P) light-sheet microscopy in the same system allows for easy selection between rapid volumetric imaging and higher resolution imaging in scattering media. Using SOPi, we demonstrate deep, large volume imaging capability inside scattering mouse brain sections and rapid imaging speeds up to 10 volumes per second in zebrafish larvae expressing genetically encoded fluorescent proteins GFP or GCaMP6s. SOPi's flexibility and steric access makes it adaptable for numerous imaging applications and broadly compatible with orthogonal techniques for actuating or interrogating neuronal structure and activity.

  8. Interactive effects of and light on growth rates and RUBISCO content of small and large centric diatoms

    NASA Astrophysics Data System (ADS)

    Li, G.; Campbell, D. A.

    2015-10-01

    Among marine phytoplankton groups, diatoms span the widest range of cell size, with resulting effects upon their nitrogen uptake, photosynthesis and growth responses to light. We grew two strains of marine centric diatoms, the small Thalassiosira pseudonana and the larger T. punctigera in high and low nitrogen media, across a range of growth light levels. Nitrogen and total proteins per cell decreased with increasing growth light in both species when grown under low nitrogen media. Surprisingly, low nitrogen increased the cellular allocation to RUBISCO and the rate of electron transport away from Photosystem II for the smaller diatom under low growth light, and for the larger diatom across the range of growth lights. Low nitrogen decreased the growth rate of the smaller diatom, particularly under higher light, but stimulated the growth rate of the larger diatom. Our results show that the high nitrogen in common growth media favours the growth rate of a small diatom but inhibits growth of a larger species.

  9. Light-sheet enhanced resolution of light field microscopy for rapid imaging of large volumes

    NASA Astrophysics Data System (ADS)

    Madrid Wolff, Jorge; Castro, Diego; Arbeláez, Pablo; Forero-Shelton, Manu

    2018-02-01

    Whole-brain imaging is challenging because it demands microscopes with high temporal and spatial resolution, which are often at odds, especially in the context of large fields of view. We have designed and built a light-sheet microscope with digital micromirror illumination and light-field detection. On the one hand, light sheets provide high resolution optical sectioning on live samples without compromising their viability. On the other hand, light field imaging makes it possible to reconstruct full volumes of relatively large fields of view from a single camera exposure; however, its enhanced temporal resolution comes at the expense of spatial resolution, limiting its applicability. We present an approach to increase the resolution of light field images using DMD-based light sheet illumination. To that end, we develop a method to produce synthetic resolution targets for light field microscopy and a procedure to correct the depth at which planes are refocused with rendering software. We measured the axial resolution as a function of depth and show a three-fold potential improvement with structured illumination, albeit by sacrificing some temporal resolution, also three-fold. This results in an imaging system that may be adjusted to specific needs without having to reassemble and realign it. This approach could be used to image relatively large samples at high rates.

  10. Inkjet-Printed Small-Molecule Organic Light-Emitting Diodes: Halogen-Free Inks, Printing Optimization, and Large-Area Patterning.

    PubMed

    Zhou, Lu; Yang, Lei; Yu, Mengjie; Jiang, Yi; Liu, Cheng-Fang; Lai, Wen-Yong; Huang, Wei

    2017-11-22

    Manufacturing small-molecule organic light-emitting diodes (OLEDs) via inkjet printing is rather attractive for realizing high-efficiency and long-life-span devices, yet it is challenging. In this paper, we present our efforts on systematical investigation and optimization of the ink properties and the printing process to enable facile inkjet printing of conjugated light-emitting small molecules. Various factors on influencing the inkjet-printed film quality during the droplet generation, the ink spreading on the substrates, and its solidification processes have been systematically investigated and optimized. Consequently, halogen-free inks have been developed and large-area patterning inkjet printing on flexible substrates with efficient blue emission has been successfully demonstrated. Moreover, OLEDs manufactured by inkjet printing the light-emitting small molecules manifested superior performance as compared with their corresponding spin-cast counterparts.

  11. Magnetic resonance-coupled fluorescence tomography scanner for molecular imaging of tissue

    NASA Astrophysics Data System (ADS)

    Davis, Scott C.; Pogue, Brian W.; Springett, Roger; Leussler, Christoph; Mazurkewitz, Peter; Tuttle, Stephen B.; Gibbs-Strauss, Summer L.; Jiang, Shudong S.; Dehghani, Hamid; Paulsen, Keith D.

    2008-06-01

    A multichannel spectrally resolved optical tomography system to image molecular targets in small animals from within a clinical MRI is described. Long source/detector fibers operate in contact mode and couple light from the tissue surface in the magnet bore to 16 spectrometers, each containing two optical gratings optimized for the near infrared wavelength range. High sensitivity, cooled charge coupled devices connected to each spectrograph provide detection of the spectrally resolved signal, with exposure times that are automated for acquisition at each fiber. The design allows spectral fitting of the remission light, thereby separating the fluorescence signal from the nonspecific background, which improves the accuracy and sensitivity when imaging low fluorophore concentrations. Images of fluorescence yield are recovered using a nonlinear reconstruction approach based on the diffusion approximation of photon propagation in tissue. The tissue morphology derived from the MR images serves as an imaging template to guide the optical reconstruction algorithm. Sensitivity studies show that recovered values of indocyanine green fluorescence yield are linear to concentrations of 1nM in a 70mm diameter homogeneous phantom, and detection is feasible to near 10pM. Phantom data also demonstrate imaging capabilities of imperfect fluorophore uptake in tissue volumes of clinically relevant sizes. A unique rodent MR coil provides optical fiber access for simultaneous optical and MR data acquisition of small animals. A pilot murine study using an orthotopic glioma tumor model demonstrates optical-MRI imaging of an epidermal growth factor receptor targeted fluorescent probe in vivo.

  12. Compact dry chemistry instruments.

    PubMed

    Terashima, K; Tatsumi, N

    1999-01-01

    Compact dry chemistry instruments are designed for use in point-of-care-testing (POCT). These instruments have a number of advantages, including light weight, compactness, ease of operation, and the ability to provide accurate results in a short time with a very small sample volume. On the other hand, reagent costs are high compared to liquid method. Moreover, differences in accuracy have been found between dry chemistry and the liquid method in external quality assessment scheme. This report examines reagent costs and shows how the total running costs associated with dry chemistry are actually lower than those associated with the liquid method. This report also describes methods for minimizing differences in accuracy between dry chemistry and the liquid method. Use of these measures is expected to increase the effectiveness of compact dry chemistry instruments in POCT applications.

  13. Community biomass handbook volume 4: enterprise development for integrated wood manufacturing

    Treesearch

    Eini Lowell; D.R. Becker; D. Smith; M. Kauffman; D. Bihn

    2017-01-01

    The Community Biomass Handbook Volume 4: Enterprise Development for Integrated Wood Manufacturing is a guide for creating sustainable business enterprises using small diameter logs and biomass. This fourth volume is a companion to three Community Biomass Handbook volumes: Volume 1: Thermal Wood Energy; Volume 2: Alaska, Where Woody Biomass Can Work; and Volume 3: How...

  14. In Situ Formation of an Azo Bridge on Proteins Controllable by Visible Light.

    PubMed

    Hoppmann, Christian; Maslennikov, Innokentiy; Choe, Senyon; Wang, Lei

    2015-09-09

    Optical modulation of proteins provides superior spatiotemporal resolution for understanding biological processes, and photoswitches built on light-sensitive proteins have been significantly advancing neuronal and cellular studies. Small molecule photoswitches could complement protein-based switches by mitigating potential interference and affording high specificity for modulation sites. However, genetic encodability and responsiveness to nonultraviolet light, two desired properties possessed by protein photoswitches, are challenging to be engineered into small molecule photoswitches. Here we developed a small molecule photoswitch that can be genetically installed onto proteins in situ and controlled by visible light. A pentafluoro azobenzene-based photoswitchable click amino acid (F-PSCaa) was designed to isomerize in response to visible light. After genetic incorporation into proteins via the expansion of the genetic code, F-PSCaa reacts with a nearby cysteine within the protein generating an azo bridge in situ. The resultant bridge is switchable by visible light and allows conformation and binding of CaM to be regulated by such light. This photoswitch should prove valuable in optobiology for its minimal interference, site flexibility, genetic encodability, and response to the more biocompatible visible light.

  15. Construction of a Liposome Dialyzer for preparation of high-value, small-volume liposome formulations

    PubMed Central

    Adamala, Katarzyna; Engelhart, Aaron E.; Kamat, Neha P.; Jin, Lin; Szostak, Jack W.

    2016-01-01

    The liposome dialyzer is a small-volume equilibrium dialysis device, built from commercially available materials, that is designed for rapid exchange of small volumes of an extraliposomal reagent pool against a liposome preparation. The dialyzer is prepared by modification of commercially available dialysis cartridges and consists of a reactor with two 300 µL chambers and a 1.56 cm2 dialysis surface area. The dialyzer is prepared in three stages: 1) disassembly of dialysis cartridges to obtain required parts; 2) assembly of the dialyzer; and 3) sealing the dialyzer with epoxy. Preparation of the dialyser takes about 1.5 h, not including overnight epoxy curing. Each round of dialysis takes 1–24 h, depending on the analyte and membrane employed. We previously used the dialyzer for small-volume nonenzymatic RNA synthesis reactions inside fatty acid vesicles. In this protocol, we demonstrate other applications, including removal of unencapsulated calcein from vesicles, remote loading, and vesicle microscopy. PMID:26020615

  16. Construction of a liposome dialyzer for the preparation of high-value, small-volume liposome formulations.

    PubMed

    Adamala, Katarzyna; Engelhart, Aaron E; Kamat, Neha P; Jin, Lin; Szostak, Jack W

    2015-06-01

    The liposome dialyzer is a small-volume equilibrium dialysis device, built from commercially available materials, that is designed for the rapid exchange of small volumes of an extraliposomal reagent pool against a liposome preparation. The dialyzer is prepared by modification of commercially available dialysis cartridges (Slide-A-Lyzer cassettes), and it consists of a reactor with two 300-μl chambers and a 1.56-cm(2) dialysis surface area. The dialyzer is prepared in three stages: (i) disassembling the dialysis cartridges to obtain the required parts, (ii) assembling the dialyzer and (iii) sealing the dialyzer with epoxy. Preparation of the dialyzer takes ∼1.5 h, not including overnight epoxy curing. Each round of dialysis takes 1-24 h, depending on the analyte and membrane used. We previously used the dialyzer for small-volume non-enzymatic RNA synthesis reactions inside fatty acid vesicles. In this protocol, we demonstrate other applications, including removal of unencapsulated calcein from vesicles, remote loading and vesicle microscopy.

  17. Cell volume and plasma membrane osmotic water permeability in epithelial cell layers measured by interferometry.

    PubMed Central

    Farinas, J; Verkman, A S

    1996-01-01

    The development of strategies to measure plasma membrane osmotic water permeability (Pf) in epithelial cells has been motivated by the identification of a family of molecular water channels. A general approach utilizing interferometry to measure cell shape and volume was developed and applied to measure Pf in cell layers. The method is based on the cell volume dependence of optical path length (OPL) for a light beam passing through the cell. The small changes in OPL were measured by interferometry. A mathematical model was developed to relate the interference signal to cell volume changes for cells of arbitrary shape and size. To validate the model, a Mach-Zehnder interference microscope was used to image OPL in an Madin Darby Canine Kidney (MDCK) cell layer and to reconstruct the three-dimensional cell shape (OPL resolution < lambda/25). As predicted by the model, a doubling of cell volume resulted in a change in OPL that was proportional to the difference in refractive indices between water and the extracellular medium. The time course of relative cell volume in response to an osmotic gradient was computed from serial interference images. To measure cell volume without microscopy and image analysis, a Mach-Zehnder interferometer was constructed in which one of two interfering laser beams passed through a flow chamber containing the cell layer. The interference signal in response to an osmotic gradient was analyzed to quantify the time course of relative cell volume. The calculated MDCK cell plasma membrane Pf of 6.1 x 10(-4) cm/s at 24 degrees C agreed with that obtained by interference microscopy and by a total internal reflection fluorescence method. Interferometry was also applied to measure the apical plasma membrane water permeability of intact toad urinary bladder; Pf increased fivefold after forskolin stimulation to 0.04 cm/s at 23 degrees C. These results establish and validate the application of interferometry to quantify cell volume and osmotic water permeability in cell layers. Images FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 4 FIGURE 6 PMID:8968620

  18. A radiographic method to estimate lung volume and its use in small mammals.

    PubMed

    Canals, Mauricio; Olivares, Ricardo; Rosenmann, Mario

    2005-01-01

    In this paper we develop a method to estimate lung volume using chest x-rays of small mammals. We applied this method to assess the lung volume of several rodents. We showed that a good estimator of the lung volume is: V*L = 0.496 x VRX approximately equal to 1/2 x VRX, where VRX is a measurement obtained from the x-ray that represents the volume of a rectangular box containing the lungs and mediastinum organs. The proposed formula may be interpreted as the volume of an ellipsoid formed by both lungs joined at their bases. When that relationship was used to estimate lung volume, values similar to those expected from allometric relationship were found in four rodents. In two others, M. musculus and R. norvegicus, lung volume was similar to reported data, although values were lower than expected.

  19. Dynamic illumination of spatially restricted or large brain volumes via a single tapered optical fiber

    PubMed Central

    Pisanello, Marco; Oldenburg, Ian A.; Sileo, Leonardo; Markowitz, Jeffrey E.; Peterson, Ralph E.; Della Patria, Andrea; Haynes, Trevor M.; Emara, Mohamed S.; Spagnolo, Barbara; Datta, Sandeep Robert; De Vittorio, Massimo; Sabatini, Bernardo L.

    2017-01-01

    Optogenetics promises spatiotemporal precise control of neural processes using light. However, the spatial extent of illumination within the brain is difficult to control and cannot be adjusted using standard fiber optics. We demonstrate that optical fibers with tapered tips can be used to illuminate either spatially restricted or large brain volumes. Remotely adjusting the light input angle to the fiber varies the light-emitting portion of the taper over several millimeters without movement of the implant. We use this mode to activate dorsal versus ventral striatum of individual mice and reveal different effects of each manipulation on motor behavior. Conversely, injecting light over the full numerical aperture of the fiber results in light emission from the entire taper surface, achieving broader and more efficient optogenetic activation of neurons when compared to the standard flat-faced fiber stimulation. Thus, tapered fibers permit focal or broad illumination that can be precisely and dynamically matched to experimental needs. PMID:28628101

  20. Dynamic illumination of spatially restricted or large brain volumes via a single tapered optical fiber.

    PubMed

    Pisanello, Ferruccio; Mandelbaum, Gil; Pisanello, Marco; Oldenburg, Ian A; Sileo, Leonardo; Markowitz, Jeffrey E; Peterson, Ralph E; Della Patria, Andrea; Haynes, Trevor M; Emara, Mohamed S; Spagnolo, Barbara; Datta, Sandeep Robert; De Vittorio, Massimo; Sabatini, Bernardo L

    2017-08-01

    Optogenetics promises precise spatiotemporal control of neural processes using light. However, the spatial extent of illumination within the brain is difficult to control and cannot be adjusted using standard fiber optics. We demonstrate that optical fibers with tapered tips can be used to illuminate either spatially restricted or large brain volumes. Remotely adjusting the light input angle to the fiber varies the light-emitting portion of the taper over several millimeters without movement of the implant. We use this mode to activate dorsal versus ventral striatum of individual mice and reveal different effects of each manipulation on motor behavior. Conversely, injecting light over the full numerical aperture of the fiber results in light emission from the entire taper surface, achieving broader and more efficient optogenetic activation of neurons, compared to standard flat-faced fiber stimulation. Thus, tapered fibers permit focal or broad illumination that can be precisely and dynamically matched to experimental needs.

  1. Fluoride Induces a Volume Reduction in CA1 Hippocampal Slices Via MAP Kinase Pathway Through Volume Regulated Anion Channels

    PubMed Central

    Lee, Jaekwang; Han, Young-Eun; Favorov, Oleg; Tommerdahl, Mark; Whitsel, Barry

    2016-01-01

    Regulation of cell volume is an important aspect of cellular homeostasis during neural activity. This volume regulation is thought to be mediated by activation of specific transporters, aquaporin, and volume regulated anion channels (VRAC). In cultured astrocytes, it was reported that swelling-induced mitogen-activated protein (MAP) kinase activation is required to open VRAC, which are thought to be important in regulatory volume decrease and in the response of CNS to trauma and excitotoxicity. It has been also described that sodium fluoride (NaF), a recognized G-protein activator and protein phosphatase inhibitor, leads to a significant MAP kinase activation in endothelial cells. However, NaF's effect in volume regulation in the brain is not known yet. Here, we investigated the mechanism of NaF-induced volume change in rat and mouse hippocampal slices using intrinsic optical signal (IOS) recording, in which we measured relative changes in intracellular and extracellular volume as changes in light transmittance through brain slices. We found that NaF (1~5 mM) application induced a reduction in light transmittance (decreased volume) in CA1 hippocampus, which was completely reversed by MAP kinase inhibitor U0126 (10 µM). We also observed that NaF-induced volume reduction was blocked by anion channel blockers, suggesting that NaF-induced volume reduction could be mediated by VRAC. Overall, our results propose a novel molecular mechanism of NaF-induced volume reduction via MAP kinase signaling pathway by activation of VRAC. PMID:27122993

  2. Volume measurements on three-dimensional photogrammetry after extended strip versus total cranial remodeling for sagittal synostosis: A comparative cohort study.

    PubMed

    van Veelen, Marie-Lise C; Jippes, Marielle; Carolina, Julius-Carl A; de Rooi, Johan; Dirven, Clemens M F; van Adrichem, Leon N A; Mathijssen, Irene M

    2016-10-01

    Surgery for sagittal synostosis aims at correction of skull shape and restoration of growth potential. Small cranial volume is associated with raised intracranial pressure (ICP). Although many techniques have been described, information on postoperative volume related to early and late remodeling is lacking. Between 2004 and 2008, a total of 95 patients were collected who underwent either early extended strip craniectomy or late total cranial remodeling according to age of presentation. Volume was measured on three-dimensional (3D) photogrammetry. Volume measurements were related to cranial index (CI), head circumference (HCsd), and signs of raised ICP. In a small subset of patients, volume measurements on 3D photogrammetry were assessed for inter- and intrarater reliability and compared to 3D computed tomography (CT). Volume was increased in all patients before and after surgery compared to normative values. Postoperatively, late total cranial remodeling resulted in a slightly larger volume than early extended strip craniectomy. Volume measurements showed a good correlation with HCsd (0.67) and a poor relationship with CI (0.13). Headache occurred more frequently in patients with a lower cranial volume. Although papilledema and reoperation showed the same trend, the numbers were too small for statistical analysis. Reproducibility of volume measurements on 3D photogrammetry was high, as was the correlation with measurements on CT. Late total cranial remodeling results in a larger postoperative volume, as measured on 3D photogrammetry, than extended strip craniectomy. Clinical signs of raised ICP occur more frequently in patients with a smaller volume. To measure volume, 3D photogrammetry is a good alternative to CT. Copyright © 2016. Published by Elsevier Ltd.

  3. Dependence of the clustering properties of galaxies on stellar velocity dispersion in the Main galaxy sample of SDSS DR10

    NASA Astrophysics Data System (ADS)

    Deng, Xin-Fa; Song, Jun; Chen, Yi-Qing; Jiang, Peng; Ding, Ying-Ping

    2014-08-01

    Using two volume-limited Main galaxy samples of the Sloan Digital Sky Survey Data Release 10 (SDSS DR10), we investigate the dependence of the clustering properties of galaxies on stellar velocity dispersion by cluster analysis. It is found that in the luminous volume-limited Main galaxy sample, except at r=1.2, richer and larger systems can be more easily formed in the large stellar velocity dispersion subsample, while in the faint volume-limited Main galaxy sample, at r≥0.9, an opposite trend is observed. According to statistical analyses of the multiplicity functions, we conclude in two volume-limited Main galaxy samples: small stellar velocity dispersion galaxies preferentially form isolated galaxies, close pairs and small group, while large stellar velocity dispersion galaxies preferentially inhabit the dense groups and clusters. However, we note the difference between two volume-limited Main galaxy samples: in the faint volume-limited Main galaxy sample, at r≥0.9, the small stellar velocity dispersion subsample has a higher proportion of galaxies in superclusters ( n≥200) than the large stellar velocity dispersion subsample.

  4. Imaging the spectral reflectance properties of bipolar radiofrequency-fused bowel tissue

    NASA Astrophysics Data System (ADS)

    Clancy, Neil T.; Arya, Shobhit; Stoyanov, Danail; Du, Xiaofei; Hanna, George B.; Elson, Daniel S.

    2015-07-01

    Delivery of radiofrequency (RF) electrical energy is used during surgery to heat and seal tissue, such as vessels, allowing resection without blood loss. Recent work has suggested that this approach may be extended to allow surgical attachment of larger tissue segments for applications such as bowel anastomosis. In a large series of porcine surgical procedures bipolar RF energy was used to resect and re-seal the small bowel in vivo with a commercial tissue fusion device (Ligasure; Covidien PLC, USA). The tissue was then imaged with a multispectral imaging laparoscope to obtain a spectral datacube comprising both fused and healthy tissue. Maps of blood volume, oxygen saturation and scattering power were derived from the measured reflectance spectra using an optimised light-tissue interaction model. A 60% increase in reflectance of visible light (460-700 nm) was observed after fusion, with the tissue taking on a white appearance. Despite this the distinctive shape of the haemoglobin absorption spectrum was still noticeable in the 460-600 nm wavelength range. Scattering power increased in the fused region in comparison to normal serosa, while blood volume and oxygen saturation decreased. Observed fusion-induced changes in the reflectance spectrum are consistent with the biophysical changes induced through tissue denaturation and increased collagen cross-linking. The multispectral imager allows mapping of the spatial extent of these changes and classification of the zone of damaged tissue. Further analysis of the spectral data in parallel with histopathological examination of excised specimens will allow correlation of the optical property changes with microscopic alterations in tissue structure.

  5. Near Infrared Photoimmunotherapy in the Treatment of Pleural Disseminated NSCLC: Preclinical Experience

    PubMed Central

    Sato, Kazuhide; Nagaya, Tadanobu; Choyke, Peter L.; Kobayashi, Hisataka

    2015-01-01

    Pleural metastases are common in patients with advanced thoracic cancers and are a cause of considerable morbidity and mortality yet is difficult to treat. Near Infrared Photoimmunotherapy (NIR-PIT) is a cancer treatment that combines the specificity of intravenously injected antibodies for targeting tumors with the toxicity induced by photosensitizers after exposure to NIR-light. Herein, we evaluate the efficacy of NIR-PIT in a mouse model of pleural disseminated non-small cell lung carcinoma (NSCLC). In vitro and in vivo experiments were conducted with a HER2, luciferase and GFP expressing NSCLC cell line (Calu3-luc-GFP). An antibody-photosensitizer conjugate (APC) consisting of trastuzumab and a phthalocyanine dye, IRDye-700DX, was synthesized. In vitro NIR-PIT cytotoxicity was assessed with dead staining, luciferase activity, and GFP fluorescence intensity. In vivo NIR-PIT was performed in mice with tumors implanted intrathoracic cavity or in the flank, and assessed by tumor volume and/or bioluminescence and fluorescence thoracoscopy. In vitro NIR-PIT-induced cytotoxicity was light dose dependent. In vivo NIR-PIT led significant reductions in both tumor volume (p = 0.002 vs. APC) and luciferase activity (p = 0.0004 vs. APC) in a flank model, and prolonged survival (p < 0.0001). Bioluminescence indicated that NIR-PIT lead to significant reduction in pleural dissemination (1 day after PIT; p = 0.0180). Fluorescence thoracoscopy confirmed the NIR-PIT effect on disseminated pleural disease. In conclusion, NIR-PIT has the ability to effectively treat pleural metastases caused by NSCLC in mice. Thus, NIR-PIT is a promising therapy for pleural disseminated tumors. PMID:25897335

  6. In vitro platelet quality in storage containers used for pediatric transfusions.

    PubMed

    Weiss, Sandra; Scammell, Kenneth; Levin, Elena; Culibrk, Brankica; Zolfaghari, Sima; Gyöngyössy-Issa, Maria I C; Acker, Jason P

    2012-08-01

    The in vitro quality of small-volume platelet (PLT) aliquots for pediatric transfusions was assessed to determine the best practice approach. Small volumes (50 mL) of single apheresis PLT components (APCs), collected on either CaridianBCT Trima or Haemonetics MCS+ instruments, were aliquoted on Days 2, 3, 4, and 5 postcollection into Fenwal PL1240 or 4R2014 bags or 60-mL polypropylene syringes. Samples were tested for in vitro quality at their recommended expiry times (4 hr for 4R2014 bags and syringes or Day 5 for PL1240 bags). Assays included pH, CD62P expression, and metabolic measures. CD62P expression increased throughout storage in all containers. Among the small-volume containers, pH, pCO(2) , lactate, and bicarbonate varied considerably. Regardless of the day of aliquoting, pCO(2) was significantly higher and pO(2) was significantly lower in gas-impermeable syringes than other containers. No bacterial growth was detected in any sample. The quality of APCs aliquoted into small-volume containers meets regulatory requirements and is generally equivalent to that of full-volume APCs at expiry. © 2012 American Association of Blood Banks.

  7. The Consequences of Metric Production for Small Manufacturers. Volume II. Case Studies of Large Business-Small Business Interaction,

    DTIC Science & Technology

    1982-02-08

    II 00 CASE STUDIES OF LARGE BUSINESS - SMALL BUSINESS INTERACTION ’C- DTIC. Henry H1. Hitchcock dlELECTE7 Joseph F. Coates Marcy M. Canavan AUGG261982...J wis&omWWS1ARET N W WASIINGTOW. OC NO$I THE CONSEQUENCES OF METRIC PRODUCTION FOR SMALL MANUFACTURERS Volume 11 CASE STUDIES OF LARGE BUSINESS ... SMALL BUSINESS INTERACTION Accesqi~r, For NTIS GRA&t DTIC TAB Unannoun~ced J’htiI’ctof _ Henry H. Hitchcock vi 1ribr i t o aes Joseph F. Coates Avail arid

  8. The Retriever, Volume 2, Nos. 1 & 2, 1967. ERIC Clearinghouse on Rural Education and Small Schools (CRESS) Newsletter.

    ERIC Educational Resources Information Center

    ERIC Clearinghouse on Rural Education and Small Schools, Las Cruces, NM.

    Volume 2, Numbers 1 and 2 of the ERIC/CRESS (Educational Research Information Center/Clearinghouse on Rural education and Small Schools) newsletter focus on the status of CRESS and innovations in the small rural school. Issue Number 1 discusses the status of the Clearinghouse at the end of 3 months into the second year of operation. A 14-item…

  9. COLLECTION EFFICIENCY OF THE HIGH VOLUME SMALL SURFACE SAMPLER ON WORN CARPETS

    EPA Science Inventory

    Collection Efficiency of the High Volume Small Surface Sampler on Worn Carpets

    Erik R. Svendsen*?, Peter S. Thorne*, Stephen J. Reynolds*?, Patrick T. O'Shaughnessy*, Alba Quinones*, Dale Zimmerman*, and Nervana Metwali*

    *University of Iowa College of Public Health<...

  10. Black Cherry Volume Tables for Furniture-Type, Flat, 4/4-Inch Dimension from Small Low-Quality Trees.

    Treesearch

    Eugene F. Landt

    1974-01-01

    Volume tables are given for yield of clear-one-side, flat dimension from small, low-quality trees and boldts removed in a stand improvement cut of 54- to 76-year-old black cherry trees from northern Pennsylvania.

  11. Soft Maple Volume Tables for Furniture-Type, Flat, 4/4-Inch Dimension from Small Low-Quality Trees

    Treesearch

    Eugene F. Landt

    1974-01-01

    Volume tables are given for yield of clear-one-side, flat dimension from small low-quality trees and bolts removed in a stand improvemtn cut of 18- to 44-year-old soft maple trees in southern Illinois.

  12. Heat capacity measurements of sub-nanoliter volumes of liquids using bimaterial microchannel cantilevers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khan, M. F.; Miriyala, N.; Hassanpourfard, M.

    Lab-on-a-Chip compatible techniques for thermal characterization of miniaturized volumes of liquid analytes are necessary in applications such as protein blotting, DNA melting, and drug development, where samples are either rare or volume-limited. We developed a closed-chamber calorimeter based on a bimaterial microchannel cantilever (BMC) for sub-nanoliter level thermal analysis. When the liquid-filled BMC is irradiated with infrared (IR) light at a specific wavelength, the IR absorption by the liquid analyte results in localized heat generation and the subsequent deflection of the BMC, due to a thermal expansion mismatch between the constituent materials. The time constant of the deflection, which ismore » dependent upon the heat capacity of the liquid analyte, can be directly measured by recording the time-dependent bending of the BMC. We have used the BMC to quantitatively measure the heat capacity of five volatile organic compounds. With a deflection noise level of ∼10 nm and a signal-to-noise ratio of 68:1, the BMC offers a sensitivity of 30.5 ms/(J g{sup −1 }K{sup −1}) and a resolution of 23 mJ/(g K) for ∼150 pl liquid for heat capacity measurements. This technique can be used for small-scale thermal characterization of different chemical and biological samples.« less

  13. Feasibility Study on Fully Automatic High Quality Translation: Volume I. Final Technical Report.

    ERIC Educational Resources Information Center

    Lehmann, Winifred P.; Stachowitz, Rolf

    The object of this theoretical inquiry is to examine the controversial issue of a fully automatic high quality translation (FAHQT) in the light of past and projected advances in linguistic theory and hardware/software capability. This first volume of a two-volume report discusses the requirements of translation and aspects of human and machine…

  14. Plankton Dynamics and Mesoscale Turbulence

    DTIC Science & Technology

    2010-06-29

    transformation of inorganic materials and light into living matter by photosynthesis ) is operated mainly by small, unicellular algae that float freely in the...ecosystems, primary production (the transformation of inorganic materials and light into living matter by photosynthesis ) is operated mainly by small...them into biomass via photosynthesis . The main limiting factors for phytoplankton growth are light and nutrient availability; for this reason

  15. Characterization and electrical properties of V 2O 5-CuO-P 2O 5 glasses

    NASA Astrophysics Data System (ADS)

    Al-Assiri, M. S.

    2008-08-01

    Characterization and electrical properties of vanadium-copper-phosphate glasses of compositions xV 2O 5-(40- x)CuO-60P 2O 5 have been reported. X-ray diffraction (XRD) confirms the amorphous nature of these glasses. It was observed that, the density ( d) decreases gradually while the molar volume ( Vm) increases with the increase of the vanadium oxide content in such glasses. This may be due to the effect of the polarizing power strength, PPS, which is a measure of ratio of the cation valance to its diameter. The dc conductivity increases while the activation energy decreases with the increase of the V 2O 5 content. The dc conductivity in the present glasses is electronic and depends strongly upon the average distance, R, between the vanadium ions. Analysis of the electrical properties has been made in the light of small polaron hopping model. The parameters obtained from the fits of the experimental data to this model are reasonable and consistent with glass composition. The conduction is attributed to non-adiabatic hopping of small polaron.

  16. Active flow control for a NACA-0012 Profile: Part II

    NASA Astrophysics Data System (ADS)

    Oualli, H.; Makadem, M.; Ouchene, H.; Ferfouri, A.; Bouabdallah, A.; Gad-El-Hak, M.

    2016-11-01

    Active flow control is applied to a NACA-0012 profile. The experiments are conducted in a wind tunnel. Using a high-resolution visible-light camera and tomography, flow visualizations are carried out. LES finite-volume 3D code is used to complement the physical experiments. The symmetric wing is clipped into two parts, and those parts extend and retract along the chord according to the same sinusoidal law we optimized last year for the same profile but clipped at an angle of 60 deg, instead of the original 90 deg. The Reynolds number range is extended to 500,000, thus covering the flying regimes of micro-UAVs, UAVs, as well as small aircraft. When the nascent cavity is open and the attack angle is 30 deg, the drag coefficient is increased by 1,300%, as compared to the uncontrolled case. However, when the cavity is covered and Re <=105 , a relatively small frequency, f <= 30 Hz, is required for the drag coefficient to drop to negative values. At the maximum Reynolds number, thrust is generated but only at much higher frequencies, 12 <= f <= 16 kHz.

  17. Construction concepts and validation of the 3D printed UST_2 modular stellarator

    NASA Astrophysics Data System (ADS)

    Queral, V.

    2015-03-01

    High accuracy, geometric complexity and thus high cost of stellarators tend to hinder the advance of stellarator research. Nowadays, new manufacturing methods might be developed for the production of small and middle-size stellarators. The methods should demonstrate advantages with respect common fabrication methods, like casting, cutting, forging and welding, for the construction of advanced highly convoluted modular stellarators. UST2 is a small modular three period quasi-isodynamic stellarator of major radius 0.26 m and plasma volume 10 litres being currently built to validate additive manufacturing (3D printing) for stellarator construction. The modular coils are wound in grooves defined on six 3D printed half period frames designed as light truss structures filled by a strong filler. A geometrically simple assembling configuration has been concocted for UST2 so as to try to lower the cost of the device while keeping the positioning accuracy of the different elements. The paper summarizes the construction and assembling concepts developed, the devised positioning methodology, the design of the coil frames and positioning elements and, an initial validation of the assembling of the components.

  18. The Dose-Volume Relationship of Small Bowel Irradiation and Acute Grade 3 Diarrhea During Chemoradiotherapy for Rectal Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robertson, John M.; Lockman, David; Yan Di

    Purpose: Previous work has found a highly significant relationship between the irradiated small-bowel volume and development of Grade 3 small-bowel toxicity in patients with rectal cancer. This study tested the previously defined parameters in a much larger group of patients. Methods and Materials: A total of 96 consecutive patients receiving pelvic radiation therapy for rectal cancer had treatment planning computed tomographic scans with small-bowel contrast that allowed the small bowel to be outlined with calculation of a small-bowel dose-volume histogram for the initial intended pelvic treatment to 45 Gy. Patients with at least one parameter above the previously determined dose-volumemore » parameters were considered high risk, whereas those with all parameters below these levels were low risk. The grade of diarrhea and presence of liquid stool was determined prospectively. Results: There was a highly significant association with small-bowel dose-volume and Grade 3 diarrhea (p {<=} 0.008). The high-risk and low-risk parameters were predictive with Grade 3 diarrhea in 16 of 51 high-risk patients and in 4 of 45 low-risk patients (p = 0.01). Patients who had undergone irradiation preoperatively had a lower incidence of Grade 3 diarrhea than those treated postoperatively (18% vs. 28%; p = 0.31); however, the predictive ability of the high-risk/low-risk parameters was better for preoperatively (p = 0.03) than for postoperatively treated patients (p = 0.15). Revised risk parameters were derived that improved the overall predictive ability (p = 0.004). Conclusions: The highly significant dose-volume relationship and validity of the high-risk and low-risk parameters were confirmed in a large group of patients. The risk parameters provided better modeling for the preoperative patients than for the postoperative patients.« less

  19. Quantification of gastrointestinal liquid volumes and distribution following a 240 mL dose of water in the fasted state.

    PubMed

    Mudie, Deanna M; Murray, Kathryn; Hoad, Caroline L; Pritchard, Susan E; Garnett, Martin C; Amidon, Gordon L; Gowland, Penny A; Spiller, Robin C; Amidon, Gregory E; Marciani, Luca

    2014-09-02

    The rate and extent of drug dissolution and absorption from solid oral dosage forms is highly dependent upon the volumes and distribution of gastric and small intestinal water. However, little is known about the time courses and distribution of water volumes in vivo in an undisturbed gut. Previous imaging studies offered a snapshot of water distribution in fasted humans and showed that water in the small intestine is distributed in small pockets. This study aimed to quantify the volume and number of water pockets in the upper gut of fasted healthy humans following ingestion of a glass of water (240 mL, as recommended for bioavailability/bioequivalence (BA/BE) studies), using recently validated noninvasive magnetic resonance imaging (MRI) methods. Twelve healthy volunteers underwent upper and lower abdominal MRI scans before drinking 240 mL (8 fluid ounces) of water. After ingesting the water, they were scanned at intervals for 2 h. The drink volume, inclusion criteria, and fasting conditions matched the international standards for BA/BE testing in healthy volunteers. The images were processed for gastric and intestinal total water volumes and for the number and volume of separate intestinal water pockets larger than 0.5 mL. The fasted stomach contained 35 ± 7 mL (mean ± SEM) of resting water. Upon drinking, the gastric fluid rose to 242 ± 9 mL. The gastric water volume declined rapidly after that with a half emptying time (T50%) of 13 ± 1 min. The mean gastric volume returned back to baseline 45 min after the drink. The fasted small bowel contained a total volume of 43 ± 14 mL of resting water. Twelve minutes after ingestion of water, small bowel water content rose to a maximum value of 94 ± 24 mL contained within 15 ± 2 pockets of 6 ± 2 mL each. At 45 min, when the glass of water had emptied completely from the stomach, total intestinal water volume was 77 ± 15 mL distributed into 16 ± 3 pockets of 5 ± 1 mL each. MRI provided unprecedented insights into the time course, number, volume, and location of water pockets in the stomach and small intestine under conditions that represent standard BA/BE studies using validated techniques. These data add to our current understanding of gastrointestinal physiology and will help improve physiological relevance of in vitro testing methods and in silico transport analyses for prediction of bioperformance of oral solid dosage forms, particularly for low solubility Biopharmaceutics Classification System (BCS) Class 2 and Class 4 compounds.

  20. Measurement of the absolute reflectance of polytetrafluoroethylene (PTFE) immersed in liquid xenon

    NASA Astrophysics Data System (ADS)

    Neves, F.; Lindote, A.; Morozov, A.; Solovov, V.; Silva, C.; Bras, P.; Rodrigues, J. P.; Lopes, M. I.

    2017-01-01

    The performance of a detector using liquid xenon (LXe) as a scintillator is strongly dependent on the collection efficiency for xenon scintillation light, which in turn is critically dependent on the reflectance of the surfaces that surround the active volume. To improve the light collection in such detectors the active volume is usually surrounded by polytetrafluoroethylene (PTFE) reflector panels, used due to its very high reflectance—even at the short wavelength of scintillation light of LXe (peaked at 178 nm). In this work, which contributed to the overall R&D effort towards the LUX-ZEPLIN (LZ) experiment, we present experimental results for the absolute reflectance measurements of three different PTFE samples (including the material used in the LUX detector) immersed in LXe for its scintillation light. The obtained results show that very high bi-hemispherical reflectance values (>= 97%) can be achieved, enabling very low energy thresholds in liquid xenon scintillator-based detectors.

  1. Study of coherent reflectometer for imaging internal structures of highly scattering media

    NASA Astrophysics Data System (ADS)

    Poupardin, Mathieu; Dolfi, Agnes

    1996-01-01

    Optical reflectometers are potentially useful tools for imaging internal structures of turbid media, particularly of biological media. To get a point by point image, an active imaging system has to distinguish light scattered from a sample volume and light scattered by other locations in the media. Operating this discrimination of light with reflectometers based on coherence can be realized in two ways: assuring a geometric selection or a temporal selection. In this paper we present both methods, showing in each case the influence of the different parameters on the size of the sample volume under the assumption of single scattering. We also study the influence on the detection efficiency of the coherence loss of the incident light resulting from multiple scattering. We adapt a model, first developed for atmospheric lidar in turbulent atmosphere, to get an analytical expression of this detection efficiency in the function of the optical coefficients of the media.

  2. Multiple-Fiber-Optic Probe For Light-Scattering Measurements

    NASA Technical Reports Server (NTRS)

    Dhadwal, Harbans Singh; Ansari, Rafat R.

    1996-01-01

    Multiple-fiber-optical probe developed for use in measuring light scattered at various angles from specimens of materials. Designed for both static and dynamic light-scattering measurements of colloidal dispersions. Probe compact, rugged unit containing no moving parts and remains stationary during operation. Not restricted to operation in controlled, research-laboratory environment. Positioned inside or outside light-scattering chamber. Provides simultaneous measurements at small angular intervals over range of angles, made to include small scattering angles by orienting probe in appropriate direction.

  3. Physics of a rapid CD4 lymphocyte count with colloidal gold.

    PubMed

    Hansen, P; Barry, D; Restell, A; Sylvia, D; Magnin, O; Dombkowski, D; Preffer, F

    2012-03-01

    The inherent surface charges and small diameters that confer colloidal stability to gold particle conjugates (immunogold) are detrimental to rapid cell surface labeling and distinct cluster definition in flow cytometric light scatter assays. Although the inherent immunogold surface charge prevents self aggregation when stored in liquid suspension, it also slows binding to cells to timeframes of hours and inhibits cell surface coverage. Although the small diameter of immunogold particles prevents settling when in liquid suspension, small particles have small light scattering cross sections and weak light scatter signals. We report a new, small particle lyophilized immunogold reagent that maintains activity after 42°C storage for a year and can be rapidly dissolved into stable liquid suspension for use in labelling cells with larger particle aggregates that have enhanced scattering cross section. Labeling requires less than 1 min at 20°C, which is ∼30 times faster than customary fluorescent antibody labeling. The labeling step involves neutralizing the surface charge of immunogold and creating specifically bound aggregates of gold on the cell surface. This process provides distinct side-scatter cluster separation with blue laser light at 488 nm, which is further improved by using red laser light at 640 nm. Similar comparisons using LED light sources showed less improvement with red light, thereby indicating that coherent light scatter is of significance in enhancing side-scatter cluster separation. The physical principles elucidated here for this technique are compatible with most flow cytometers; however, future studies of its clinical efficacy should be of primary interest in point-of-care applications where robust reagents and rapid results are important. Copyright © 2011 International Society for Advancement of Cytometry.

  4. Implications of improved diagnostic imaging of small nodal metastases in head and neck cancer: Radiotherapy target volume transformation and dose de-escalation.

    PubMed

    van den Bosch, Sven; Vogel, Wouter V; Raaijmakers, Cornelis P; Dijkema, Tim; Terhaard, Chris H J; Al-Mamgani, Abrahim; Kaanders, Johannes H A M

    2018-05-03

    Diagnostic imaging continues to evolve, and now has unprecedented accuracy for detecting small nodal metastasis. This influences the tumor load in elective target volumes and subsequently has consequences for the radiotherapy dose required to control disease in these volumes. Small metastases that used to remain subclinical and were included in elective volumes, will nowadays be detected and included in high-dose volumes. Consequentially, high-dose volumes will more often contain low-volume disease. These target volume transformations lead to changes in the tumor burden in elective and "gross" tumor volumes with implications for the radiotherapy dose prescribed to these volumes. For head and neck tumors, nodal staging has evolved from mere palpation to combinations of high-resolution imaging modalities. A traditional nodal gross tumor volume in the neck typically had a minimum diameter of 10-15 mm, while nowadays much smaller tumor deposits are detected in lymph nodes. However, the current dose levels for elective nodal irradiation were empirically determined in the 1950s, and have not changed since. In this report the radiobiological consequences of target volume transformation caused by modern imaging of the neck are evaluated, and theoretically derived reductions of dose in radiotherapy for head and neck cancer are proposed. The concept of target volume transformation and subsequent strategies for dose adaptation applies to many other tumor types as well. Awareness of this concept may result in new strategies for target definition and selection of dose levels with the aim to provide optimal tumor control with less toxicity. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  5. 40 CFR 1045.635 - What special provisions apply for small-volume engine manufacturers?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false What special provisions apply for small-volume engine manufacturers? 1045.635 Section 1045.635 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...

  6. 40 CFR 1045.635 - What special provisions apply for small-volume engine manufacturers?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false What special provisions apply for small-volume engine manufacturers? 1045.635 Section 1045.635 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...

  7. 40 CFR 1045.635 - What special provisions apply for small-volume engine manufacturers?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false What special provisions apply for small-volume engine manufacturers? 1045.635 Section 1045.635 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...

  8. 40 CFR 1045.635 - What special provisions apply for small-volume engine manufacturers?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false What special provisions apply for small-volume engine manufacturers? 1045.635 Section 1045.635 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...

  9. 40 CFR 86.1823-08 - Durability demonstration procedures for exhaust emissions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) General Compliance Provisions for Control of Air Pollution From New and In... § 86.1801. Eligible small volume manufacturers or small volume test groups may optionally meet the...

  10. 40 CFR 86.1823-08 - Durability demonstration procedures for exhaust emissions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) General Compliance Provisions for Control of Air Pollution From New and In... § 86.1801. Eligible small volume manufacturers or small volume test groups may optionally meet the...

  11. 40 CFR 86.1824-08 - Durability demonstration procedures for evaporative emissions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... for evaporative emissions. Eligible small-volume manufacturers or small-volume test groups may...-based measurements except the bleed emission test. The standard for bleed emissions applies for the full... manufacturer must conduct at least one evaporative emission test at each of the five different mileage points...

  12. 40 CFR 86.1824-08 - Durability demonstration procedures for evaporative emissions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the applicability provisions of § 86.1801. Eligible small volume manufacturers or small volume test... manufacturer must conduct at least one evaporative emission test at each of the five different mileage points... the highest mileage point run during mileage accumulation (e.g. the full useful life mileage...

  13. 40 CFR 1045.635 - What special provisions apply for small-volume engine manufacturers?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false What special provisions apply for small-volume engine manufacturers? 1045.635 Section 1045.635 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM SPARK-IGNITION PROPULSION...

  14. 40 CFR 86.095-14 - Small-volume manufacturers certification procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-Fueled, Liquefied Petroleum Gas-Fueled and Methanol-Fueled Heavy-Duty Vehicles § 86.095-14 Small-volume... are exempted from the high altitude emission standards. (18) Proof that the manufacturer has obtained... as proof that the manufacturer has obtained or entered an agreement to purchase the insurance policy...

  15. 40 CFR 86.095-14 - Small-volume manufacturers certification procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-Fueled, Liquefied Petroleum Gas-Fueled and Methanol-Fueled Heavy-Duty Vehicles § 86.095-14 Small-volume... are exempted from the high altitude emission standards. (18) Proof that the manufacturer has obtained... as proof that the manufacturer has obtained or entered an agreement to purchase the insurance policy...

  16. Compilation of 1985 annual reports of the Navy elf (extremely low frequency) communications system ecological monitoring program. Volume 2. Tabs D-G. Annual progress report, January-December 1985

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Band, R.N.; Snider, R.J.; Snider, R.M.

    1986-07-01

    This volume consists of the following reports: Soil Amoeba; Soil and Litter Arthropoda and Earthworm Studies; Biological Studies on Pollinating Insects: Megachilid Bees; Small Vertebrates: Small Mammals and Nesting Birds.

  17. 40 CFR 86.1826-01 - Assigned deterioration factors for small-volume manufacturers and small-volume test groups.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... applying deterioration factors. Manufacturers may use assigned deterioration factors that the Administrator determines and prescribes. (1) The deterioration factors will be the Administrator's estimate, periodically... using the industry-wide database of previously completed durability data vehicles or engines used for...

  18. Phase-field simulations of coherent precipitate morphologies and coarsening kinetics

    NASA Astrophysics Data System (ADS)

    Vaithyanathan, Venugopalan

    2002-09-01

    The primary aim of this research is to enhance the fundamental understanding of coherent precipitation reactions in advanced metallic alloys. The emphasis is on a particular class of precipitation reactions which result in ordered intermetallic precipitates embedded in a disordered matrix. These precipitation reactions underlie the development of high-temperature Ni-base superalloys and ultra-light aluminum alloys. Phase-field approach, which has emerged as the method of choice for modeling microstructure evolution, is employed for this research with the focus on factors that control the precipitate morphologies and coarsening kinetics, such as precipitate volume fractions and lattice mismatch between precipitates and matrix. Two types of alloy systems are considered. The first involves L1 2 ordered precipitates in a disordered cubic matrix, in an attempt to model the gamma' precipitates in Ni-base superalloys and delta' precipitates in Al-Li alloys. The effect of volume fraction on coarsening kinetics of gamma' precipitates was investigated using two-dimensional (2D) computer simulations. With increase in volume fraction, larger fractions of precipitates were found to have smaller aspect ratios in the late stages of coarsening, and the precipitate size distributions became wider and more positively skewed. The most interesting result was associated with the effect of volume fraction on the coarsening rate constant. Coarsening rate constant as a function of volume fraction extracted from the cubic growth law of average half-edge length was found to exhibit three distinct regimes: anomalous behavior or decreasing rate constant with volume fraction at small volume fractions ( ≲ 20%), volume fraction independent or constant behavior for intermediate volume fractions (˜20--50%), and the normal behavior or increasing rate constant with volume fraction for large volume fractions ( ≳ 50%). The second alloy system considered was Al-Cu with the focus on understanding precipitation of metastable tetragonal theta'-Al 2Cu in a cubic Al solid solution matrix. In collaboration with Chris Wolverton at Ford Motor Company, a multiscale model, which involves a novel combination of first-principles atomistic calculations with a mesoscale phase-field microstructure model, was developed. Reliable energetics in the form of bulk free energy, interfacial energy and parameters for calculating the elastic energy were obtained using accurate first-principles calculations. (Abstract shortened by UMI.)

  19. Longevity of a small shield volcano revealed by crypto-tephra studies (Rangitoto volcano, New Zealand): Change in eruptive behavior of a basaltic field

    NASA Astrophysics Data System (ADS)

    Shane, Phil; Gehrels, Maria; Zawalna-Geer, Aleksandra; Augustinus, Paul; Lindsay, Jan; Chaillou, Isabelle

    2013-05-01

    The life-span of small volcanoes in terrestrial basaltic fields, commonly considered 'monogenetic', can be difficult to assess due to a paucity of datable materials capable of providing a 102-103-year age resolution. We have used microscopic tephra layers (crypto-tephra) in lake sediments to determine the longevity of Rangitoto volcano, a small shield that represents the most recent volcanism in the Auckland Volcanic Field (AVF), New Zealand. Previous studies suggested construction in a relatively short interval at ~ 550-500 cal yrs BP. In contrast, the tephra record shows evidence of intermittent activity from 1498 ± 140 to (at least) 504 ± 6 cal yrs BP, a longevity of ~ 1000 years. Rangitoto volcano is thought to represent about half the magma erupted in the 250-ka-history of AVF. Thus, the AVF has experienced a dramatic shift to prolonged and voluminous central-vent volcanism in its most recent history. This demonstrates the difficulty in determining time-erupted volume relationships in such fields. Previous AVF hazard-risk modeling based on isolated, short-lived (< 1 year) phenomena at sites that have not experienced activity needs to be revisited in light of the new Rangitoto chronology.

  20. Ultra-high-Q three-dimensional photonic crystal nano-resonators.

    PubMed

    Tang, Lingling; Yoshie, Tomoyuki

    2007-12-10

    Two nano-resonator modes are designed in a woodpile three-dimensional photonic crystal by the modulation of unit cell size along a low-loss optical waveguide. One is a dipole mode with 2.88 cubic half-wavelengths mode volume. The other is a quadrupole mode with 8.3 cubic half-wavelengths mode volume. Light is three-dimensionally confined by a complete photonic band gap so that, in the analyzed range, the quality factor exponentially increases as the increase in the number of unit cells used for confinement of light.

  1. Design of light-small high-speed image data processing system

    NASA Astrophysics Data System (ADS)

    Yang, Jinbao; Feng, Xue; Li, Fei

    2015-10-01

    A light-small high speed image data processing system was designed in order to meet the request of image data processing in aerospace. System was constructed of FPGA, DSP and MCU (Micro-controller), implementing a video compress of 3 million pixels@15frames and real-time return of compressed image to the upper system. Programmable characteristic of FPGA, high performance image compress IC and configurable MCU were made best use to improve integration. Besides, hard-soft board design was introduced and PCB layout was optimized. At last, system achieved miniaturization, light-weight and fast heat dispersion. Experiments show that, system's multifunction was designed correctly and worked stably. In conclusion, system can be widely used in the area of light-small imaging.

  2. Improving the accuracy of ionization chamber dosimetry in small megavoltage x-ray fields

    NASA Astrophysics Data System (ADS)

    McNiven, Andrea L.

    The dosimetry of small x-ray fields is difficult, but important, in many radiation therapy delivery methods. The accuracy of ion chambers for small field applications, however, is limited due to the relatively large size of the chamber with respect to the field size, leading to partial volume effects, lateral electronic disequilibrium and calibration difficulties. The goal of this dissertation was to investigate the use of ionization chambers for the purpose of dosimetry in small megavoltage photon beams with the aim of improving clinical dose measurements in stereotactic radiotherapy and helical tomotherapy. A new method for the direct determination of the sensitive volume of small-volume ion chambers using micro computed tomography (muCT) was investigated using four nominally identical small-volume (0.56 cm3) cylindrical ion chambers. Agreement between their measured relative volume and ionization measurements (within 2%) demonstrated the feasibility of volume determination through muCT. Cavity-gas calibration coefficients were also determined, demonstrating the promise for accurate ion chamber calibration based partially on muCT. The accuracy of relative dose factor measurements in 6MV stereotactic x-ray fields (5 to 40mm diameter) was investigated using a set of prototype plane-parallel ionization chambers (diameters of 2, 4, 10 and 20mm). Chamber and field size specific correction factors ( CSFQ ), that account for perturbation of the secondary electron fluence, were calculated using Monte Carlo simulation methods (BEAM/EGSnrc simulations). These correction factors (e.g. CSFQ = 1.76 (2mm chamber, 5mm field) allow for accurate relative dose factor (RDF) measurement when applied to ionization readings, under conditions of electronic disequilibrium. With respect to the dosimetry of helical tomotherapy, a novel application of the ion chambers was developed to characterize the fan beam size and effective dose rate. Characterization was based on an adaptation of the computed tomography dose index (CTDI), a concept normally used in diagnostic radiology. This involved experimental determination of the fan beam thickness using the ion chambers to acquire fan beam profiles and extrapolation to a 'zero-size' detector. In conclusion, improvements have been made in the accuracy of small field dosimetry measurements in stereotactic radiotherapy and helical tomotherapy. This was completed through introduction of an original technique involving micro-CT imaging for sensitive volume determination and potentially ion chamber calibration coefficients, the use of appropriate Monte Carlo derived correction factors for RDF measurement, and the exploitation of the partial volume effect for helical tomotherapy fan beam dosimetry. With improved dosimetry for a wide range of challenging small x-ray field situations, it is expected that the patient's radiation safety will be maintained, and that clinical trials will adopt calibration protocols specialized for modern radiotherapy with small fields or beamlets. Keywords. radiation therapy, ionization chambers, small field dosimetry, stereotactic radiotherapy, helical tomotherapy, micro-CT.

  3. Omnidirectional and broadband absorption enhancement from trapezoidal Mie resonators in semiconductor metasurfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pala, Ragip A.; Butun, Serkan; Aydin, Koray

    2016-09-19

    Light trapping in planar ultrathin-film solar cells is limited due to a small number of optical modes available in the thin-film slab. A nanostructured thin-film design could surpass this limit by providing broadband increase in the local density of states in a subwavelength volume and maintaining efficient coupling of light. Here we report a broadband metasurface design, enabling efficient and broadband absorption enhancement by direct coupling of incoming light to resonant modes of subwavelength scale Mie nanoresonators defined in the thin-film active layer. Absorption was investigated both theoretically and experimentally in prototypes consisting of lithographically patterned, two-dimensional periodic arrays ofmore » silicon nanoresonators on silica substrates. A crossed trapezoid resonator shape of rectangular cross section is used to excite broadband Mie resonances across visible and near-IR spectra. Our numerical simulations, optical absorption measurements and photocurrent spectral response measurements demonstrate that crossed trapezoidal Mie resonant structures enable angle-insensitive, broadband absorption. A short circuit current density of 12.0 mA/cm 2 is achieved in 210 nm thick patterned Si films, yielding a 4-fold increase compared to planar films of the same thickness. As a result, it is suggested that silicon metasurfaces with Mie resonator arrays can provide useful insights to guide future ultrathin-film solar cell designs incorporating nanostructured thin active layers.« less

  4. Fiber Loop Ringdown — a Time-Domain Sensing Technique for Multi-Function Fiber Optic Sensor Platforms: Current Status and Design Perspectives

    PubMed Central

    Wang, Chuji

    2009-01-01

    Fiber loop ringdown (FLRD) utilizes an inexpensive telecommunications light source, a photodiode, and a section of single-mode fiber to form a uniform fiber optic sensor platform for sensing various quantities, such as pressure, temperature, strain, refractive index, chemical species, biological cells, and small volume of fluids. In FLRD, optical losses of a light pulse in a fiber loop induced by changes in a quantity are measured by the light decay time constants. FLRD measures time to detect a quantity; thus, FLRD is referred to as a time-domain sensing technique. FLRD sensors have near real-time response, multi-pass enhanced high-sensitivity, and relatively low cost (i.e., without using an optical spectral analyzer). During the last eight years since the introduction of the original form of fiber ringdown spectroscopy, there has been increasing interest in the FLRD technique in fiber optic sensor developments, and new application potential is being explored. This paper first discusses the challenging issues in development of multi-function, fiber optic sensors or sensor networks using current fiber optic sensor sensing schemes, and then gives a review on current fiber optic sensor development using FLRD technique. Finally, design perspectives on new generation, multi-function, fiber optic sensor platforms using FLRD technique are particularly presented. PMID:22408471

  5. Deviation from symmetrically self-similar branching in trees predicts altered hydraulics, mechanics, light interception and metabolic scaling.

    PubMed

    Smith, Duncan D; Sperry, John S; Enquist, Brian J; Savage, Van M; McCulloh, Katherine A; Bentley, Lisa P

    2014-01-01

    The West, Brown, Enquist (WBE) model derives symmetrically self-similar branching to predict metabolic scaling from hydraulic conductance, K, (a metabolism proxy) and tree mass (or volume, V). The original prediction was Kα V(0.75). We ask whether trees differ from WBE symmetry and if it matters for plant function and scaling. We measure tree branching and model how architecture influences K, V, mechanical stability, light interception and metabolic scaling. We quantified branching architecture by measuring the path fraction, Pf : mean/maximum trunk-to-twig pathlength. WBE symmetry produces the maximum, Pf = 1.0. We explored tree morphospace using a probability-based numerical model constrained only by biomechanical principles. Real tree Pf ranged from 0.930 (nearly symmetric) to 0.357 (very asymmetric). At each modeled tree size, a reduction in Pf led to: increased K; decreased V; increased mechanical stability; and decreased light absorption. When Pf was ontogenetically constant, strong asymmetry only slightly steepened metabolic scaling. The Pf ontogeny of real trees, however, was 'U' shaped, resulting in size-dependent metabolic scaling that exceeded 0.75 in small trees before falling below 0.65. Architectural diversity appears to matter considerably for whole-tree hydraulics, mechanics, photosynthesis and potentially metabolic scaling. Optimal architectures likely exist that maximize carbon gain per structural investment. © 2013 The Authors. New Phytologist © 2013 New Phytologist Trust.

  6. Roadway lighting's impact on altering soybean growth : volume 1.

    DOT National Transportation Integrated Search

    2017-01-01

    The impact of roadway lighting on soybean plant growth and development was measured in situ at seven locations in the state of : Illinois. The plant data collection included periodic height, reproductive-stage, and Normalized Difference Vegetation In...

  7. Joint Small Arms Technology Development Strategy for Joint Service Small Arms Science and Technology Investments

    DTIC Science & Technology

    2016-01-26

    Scope/Objectives Reiterating, this discussion is limited to small arms; those of .50 caliber and smaller plus low velocity and high 40mm...ballistic trajectory are included, plus abilities to engage targets in defilade such as by fragmentation effects for enemy located behind retaining walls...Electromagnetic Pulse (EMP) Weapons 3 2 Light Weight Small Arms / Light Weight Materials 2 2 Munition Guidance 2 2 Pain Beams 2 2 Barrel Coatings 1 1

  8. Measuring pedestrian volumes and conflicts. Volume III, Measuring pedestrian volumes : a users manual

    DOT National Transportation Integrated Search

    1988-03-01

    Users of the manual are expected to be in divisions responsible for pedestrian safety in cities, counties, and other jurisdictions. The users manual outlines a step-by-step procedure to measure pedestrian volumes using small count intervals. Appendix...

  9. Surmounting All Odds: Education, Opportunity, and Society in the New Millennium. Volume 1. A Volume in Research on African American Education.

    ERIC Educational Resources Information Center

    Yeakey, Carol Camp, Ed.; Henderson, Ronald D., Ed.

    This volume includes the first 15 papers in a 32-paper collection. After a prologue by Mkhululi David Graham Du Bois entitled "Seeking Truth in Research", the papers are: (1) "`Knowledge is Light, Knowledge is Power': African American Education in Antebellum America" (Christopher M. Span); (2) "Curriculum, Culture, and…

  10. Studying Phototropism Using a Small Growth Chamber.

    ERIC Educational Resources Information Center

    Fisher, Maryanna, F.; Llewellyn, Gerald C.

    1978-01-01

    Describes a simple and inexpensive way to construct two small growth chambers for studying phototropism in the science classroom. One chamber is designed to illustrate how plants grow around obstacles to reach light and the other to illustrate directional light responses. (HM)

  11. Industrial Fuel Gas Demonstration Plant Program. Volume 1. Demonstration plant environmental analysis (Deliverable No. 27)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gray, Robert W.; Swift, Richard J.; Krause, Arthur J.

    1979-08-01

    This environmental report describes the proposed action to construct, test and operate a coal gasification demonstration plant in Memphis, Tennessee, under the co-sponsorship of the Memphis Light, Gas and Water Division (MLGW) and the US Department of Energy (DOE). This document is Volume I of a three-volume Environmental Report. Volume I consists of the Summary, Introduction and the Description of the Proposed Action. Volume II consists of the Description of the Existing Environment. Volume III contains the Environmental Impacts of the Proposed Action, Mitigating Measures and Alternatives to the Proposed Action.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, Yung-Ting; Department of Electrical Engineering, Graduate Institute of Photonics and Optoelectronics, National Taiwan University, Taipei, Taiwan 10617, Taiwan; Liu, Shun-Wei

    Single-layer blue phosphorescence organic light emitting diodes (OLEDs) with either small-molecule or polymer hosts are fabricated using solution process and the performances of devices with different hosts are investigated. The small-molecule device exhibits luminous efficiency of 14.7 cd/A and maximum power efficiency of 8.39 lm/W, which is the highest among blue phosphorescence OLEDs with single-layer solution process and small molecular hosts. Using the same solution process for all devices, comparison of light out-coupling enhancement, with brightness enhancement film (BEF), between small-molecule and polymer based OLEDs is realized. Due to different dipole orientation and anisotropic refractive index, polymer-based OLEDs would trap less lightmore » than small molecule-based OLEDs internally, about 37% better based simulation results. In spite of better electrical and spectroscopic characteristics, including ambipolar characteristics, higher carrier mobility, higher photoluminescence quantum yield, and larger triplet state energy, the overall light out-coupling efficiency of small molecule-based devices is worse than that of polymer-based devices without BEF. However, with BEF for light out-coupling enhancement, the improved ratio in luminous flux and luminous efficiency for small molecule based device is 1.64 and 1.57, respectively, which are significantly better than those of PVK (poly-9-vinylcarbazole) devices. In addition to the theoretical optical simulation, the experimental data also confirm the origins of differential light-outcoupling enhancement. The maximum luminous efficiency and power efficiency are enhanced from 14.7 cd/A and 8.39 lm/W to 23 cd/A and 13.2 lm/W, respectively, with laminated BEF, which are both the highest so far for single-layer solution-process blue phosphorescence OLEDs with small molecule hosts.« less

  13. Matrix elements of Δ B =0 operators in heavy hadron chiral perturbation theory

    NASA Astrophysics Data System (ADS)

    Lee, Jong-Wan

    2015-05-01

    We study the light-quark mass and spatial volume dependence of the matrix elements of Δ B =0 four-quark operators relevant for the determination of Vu b and the lifetime ratios of single-b hadrons. To this end, one-loop diagrams are computed in the framework of heavy hadron chiral perturbation theory with partially quenched formalism for three light-quark flavors in the isospin limit; flavor-connected and -disconnected diagrams are carefully analyzed. These calculations include the leading light-quark flavor and heavy-quark spin symmetry breaking effects in the heavy hadron spectrum. Our results can be used in the chiral extrapolation of lattice calculations of the matrix elements to the physical light-quark masses and to infinite volume. To provide insight on such chiral extrapolation, we evaluate the one-loop contributions to the matrix elements containing external Bd, Bs mesons and Λb baryon in the QCD limit, where sea and valence quark masses become equal. In particular, we find that the matrix elements of the λ3 flavor-octet operators with an external Bd meson receive the contributions solely from connected diagrams in which current lattice techniques are capable of precise determination of the matrix elements. Finite volume effects are at most a few percent for typical lattice sizes and pion masses.

  14. Three-dimensional laser velocimeter simultaneity detector

    NASA Technical Reports Server (NTRS)

    Brown, James L. (Inventor)

    1990-01-01

    A three-dimensional laser Doppler velocimeter has laser optics for a first channel positioned to create a probe volume in space, and laser optics and for second and third channels, respectively, positioned to create entirely overlapping probe volumes in space. The probe volumes and overlap partially in space. The photodetector is positioned to receive light scattered by a particle present in the probe volume, while photodetectors and are positioned to receive light scattered by a particle present in the probe volume. The photodetector for the first channel is directly connected to provide a first channel analog signal to frequency measuring circuits. The first channel is therefore a primary channel for the system. Photodetectors and are respectively connected through a second channel analog signal attenuator to frequency measuring circuits and through a third channel analog signal attenuator to frequency measuring circuits. The second and third channels are secondary channels, with the second and third channels analog signal attenuators and controlled by the first channel measurement burst signal on line. The second and third channels analog signal attenuators and attenuate the second and third channels analog signals only when the measurement burst signal is false.

  15. A contact-free volumetric measurement of facial volume after third molar osteotomy: proof of concept.

    PubMed

    Brüllmann, Dan; Jürchott, Lena Marie; John, Christoph; Trempler, Christina; Schwanecke, Ulrich; Schulze, Ralf K W

    2014-01-01

    The present study tested the reliability of an optical scanning device for the objective assessment of postoperative facial swelling. Twenty control subjects bearing a defined volume of water (10-30 mL) in an intraorally carried balloon were tested to assess the measurement accuracy of the device. As a proof of concept, facial volumes of 59 surgical cases were recorded before osteotomy and 1 and 7 days after intervention with the use of a structured light scanner. The median difference between the applied and the measured volumes was 0.67 mL for the control test with the artificial swelling simulated using water balloons. For subjects having third molar osteotomy, extraoral volume increased to 5.29 cm(3) 1 day after surgery (95% CI 5.22-8.52) and decreased to 0.00 mL (95% CI 0.85-2.55) after 7 days. Contact-free visible-light 3-dimensional scanning is reliable for the objective assessment of postoperative facial swelling. Copyright © 2014 Elsevier Inc. All rights reserved.

  16. 40 CFR 94.209 - Special provisions for post-manufacture marinizers and small-volume manufacturers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...-manufacture marinizers and small-volume manufacturers. 94.209 Section 94.209 Protection of Environment... COMPRESSION-IGNITION ENGINES Certification Provisions § 94.209 Special provisions for post-manufacture... demonstrate one of the following: (1) It is a post-manufacture marinizer and that the base engines used for...

  17. Measuring Very Small Quantities: Fascinating Suggestions for Math or Science.

    ERIC Educational Resources Information Center

    Thompson, John Taylor

    1989-01-01

    Described are several activities for teaching children to determine mass and volume. Included are the masses of a water drop and a grain of rice; the volume of a water drop and small solids; and measuring the width of a hair. Procedures and materials for the activities are discussed. (CW)

  18. Scanning laser beam displays based on a 2D MEMS

    NASA Astrophysics Data System (ADS)

    Niesten, Maarten; Masood, Taha; Miller, Josh; Tauscher, Jason

    2010-05-01

    The combination of laser light sources and MEMS technology enables a range of display systems such as ultra small projectors for mobile devices, head-up displays for vehicles, wearable near-eye displays and projection systems for 3D imaging. Images are created by scanning red, green and blue lasers horizontally and vertically with a single two-dimensional MEMS. Due to the excellent beam quality of laser beams, the optical designs are efficient and compact. In addition, the laser illumination enables saturated display colors that are desirable for augmented reality applications where a virtual image is used. With this technology, the smallest projector engine for high volume manufacturing to date has been developed. This projector module has a height of 7 mm and a volume of 5 cc. The resolution of this projector is WVGA. No additional projection optics is required, resulting in an infinite focus depth. Unlike with micro-display projection displays, an increase in resolution will not lead to an increase in size or a decrease in efficiency. Therefore future projectors can be developed that combine a higher resolution in an even smaller and thinner form factor with increased efficiencies that will lead to lower power consumption.

  19. Tripolar acytokinetic mitosis and formation of feto-maternal syncytia in the bovine placentome: different modes of the generation of multinuclear cells.

    PubMed

    Klisch, K; Pfarrer, C; Schuler, G; Hoffmann, B; Leiser, R

    1999-08-01

    The vast majority of trophoblast giant cells in the ruminant placenta are binuclear and are believed to derive from mononuclear trophoblastic cells by a single acytokinetic mitosis. There is no satisfactory explanation for the generation of the small proportion of trophoblast giant cells with one, three, or more nuclei. In this light-and electronmicroscopic study of bovine placentomal tissue from the second half of gestation, developmental stages of the trophoblast giant cells are investigated. Large mitotic figures indicate mitotic polyploidization, which is proposed to be due to two subsequent acytokinetic mitoses. Tripolar mitoses offer an explanation for the development of trinucleate trophoblast giant cells. Measurements of nuclear volumes in a series of semithin sections revealed that three size classes of trophoblast giant cells occur. The approximately doubling of nuclear volume between each class is thought to reflect different levels of DNA content that result from polyploidization in this cell type. Although trinuclear feto-maternal hybrid cells are the standard outcome of the fusion of binuclear trophoblast giant cells with uterine epithelial cells, some syncytia with at least five nuclei were observed in the uterine epithelium.

  20. Impact melting early in lunar history

    NASA Technical Reports Server (NTRS)

    Lange, M. A.; Ahrens, T. J.

    1979-01-01

    The total amount of impact melt produced during early lunar history is examined in light of theoretically and experimentally determined relations between crater diameter (D) and impact melt volume. The time dependence of the melt production is given by the time dependent impact rate as derived from cratering statistics for two different crater-size classes. Results show that small scale cratering (D less than or equal to 30 km) leads to melt volumes which fit selected observations specifying the amount of impact melt contained in the lunar regolith and in craters with diameters less than 10 km. Larger craters (D greater than 30 km) are capable of forming the abundant impact melt breccias found on the lunar surface. The group of large craters (D greater than 30 km) produces nearly 10 times as much impact melt as all the smaller craters, and thus, the large impacts dominate the modification of the lunar surface. A contradiction between the distribution of radiometric rock ages and a model of exponentially decreasing cratering rate going back to 4.5 b.y. is reflected in uncertainty in the distribution of impact melt as a function of time on the moon.

  1. Data Base for Light-Weight Automotive Diesel Power Plants : Volume 3. Miscellaneous Data.

    DOT National Transportation Integrated Search

    1979-12-01

    The effects of fuel economy, emissions, passenger car safety and other variables due to the installation of light-weight Diesel powerplants were studied. Experimental data was obtained on naturally aspirated and turbocharged Diesel engines installed ...

  2. Data Base for Light-Weight Automotive Diesel Power Plants. Volume 2: Discussion and Results.

    DOT National Transportation Integrated Search

    1979-12-01

    The effects on fuel economy, emissions, passenger car safety and other variables due to the installation of light-weight Diesel powerplants were studied. Experimental data was obtained on naturally aspirated and turbocharged Diesel engines installed ...

  3. Data Base for Light-Weight Automotive Diesel Power Plants: Volume 1. Executive Summary.

    DOT National Transportation Integrated Search

    1979-12-01

    The effects on fuel economy, emissions, passenger car safety and other variables due to the installation of light-weight Diesel powerplants were studied. Experimental data was obtained on naturally aspirated and turbocharged Diesel engines installed ...

  4. Structured light: theory and practice and practice and practice...

    NASA Astrophysics Data System (ADS)

    Keizer, Richard L.; Jun, Heesung; Dunn, Stanley M.

    1991-04-01

    We have developed a structured light system for noncontact 3-D measurement of human body surface areas and volumes. We illustrate the image processing steps and algorithms used to recover range data from a single camera image, reconstruct a complete surface from one or more sets of range data, and measure areas and volumes. The development of a working system required the solution to a number of practical problems in image processing and grid labeling (the stereo correspondence problem for structured light). In many instances we found that the standard cookbook techniques for image processing failed. This was due in part to the domain (human body), the restrictive assumptions of the models underlying the cookbook techniques, and the inability to consistently predict the outcome of the image processing operations. In this paper, we will discuss some of our successes and failures in two key steps in acquiring range data using structured light: First, the problem of detecting intersections in the structured light grid, and secondly, the problem of establishing correspondence between projected and detected intersections. We will outline the problems and solutions we have arrived at after several years of trial and error. We can now measure range data with an r.m.s. relative error of 0.3% and measure areas on the human body surface within 3% and volumes within 10%. We have found that the solution to building a working vision system requires the right combination of theory and experimental verification.

  5. Red and infrared light distribution in blood

    NASA Astrophysics Data System (ADS)

    de Magalhães, Ana Carolina; Yoshimura, Elisabeth M.

    2013-02-01

    Low level laser therapy (LLLT) is used in several applications, including the reduction of inflammatory processes. It might be used to prevent the systemic inflammatory response syndrome (SIRS), which some patients develop after cardiopulmonary bypass (CPB) surgery. The objectives of this study were to investigate light distribution inside blood, in order to implement the LLLT during CPB, and, through this study, to determine the best wavelength and the best way to perform the treatment. The blood, diluted to the same conditions of CPB procedure was contained inside a cuvette and an optical fiber was used to collect the scattered light. Two wavelengths were used: 632.8 nm and 820 nm. Light distribution in blood inside CPB tubes was also evaluated. Compared to the 820 nm light, the 632.8 nm light is scattered further away from the laser beam, turning it possible that a bigger volume of blood be treated. The blood should be illuminated through the smallest diameter CPB tube, using at least four distinct points around it, in only one cross section, because the blood is kept passing through the tube all the time and the whole volume will be illuminated.

  6. Boundary Element Method in a Self-Gravitating Elastic Half-Space and Its Application to Deformation Induced by Magma Chambers

    NASA Astrophysics Data System (ADS)

    Fang, M.; Hager, B. H.

    2014-12-01

    In geophysical applications the boundary element method (BEM) often carries the essential physics in addition to being an efficient numerical scheme. For use of the BEM in a self-gravitating uniform half-space, we made extra effort and succeeded in deriving the fundamental solution analytically in closed-form. A problem that goes deep into the heart of the classic BEM is encountered when we try to apply the new fundamental solution in BEM for deformation field induced by a magma chamber or a fluid-filled reservoir. The central issue of the BEM is the singular integral arising from determination of the boundary values. A widely employed technique is to rescale the singular boundary point into a small finite volume and then shrink it to extract the limits. This operation boils down to the calculation of the so-called C-matrix. Authors in the past take the liberty of either adding or subtracting a small volume. By subtracting a small volume, the C-matrix is (1/2)I on a smooth surface, where I is the identity matrix; by adding a small volume, we arrive at the same C-matrix in the form of I - (1/2)I. This evenness is a result of the spherical symmetry of Kelvin's fundamental solution employed. When the spherical symmetry is broken by gravity, the C-matrix is polarized. And we face the choice between right and wrong, for adding and subtracting a small volume yield different C-matrices. Close examination reveals that both derivations, addition and subtraction of a small volume, are ad hoc. To resolve the issue we revisit the Somigliana identity with a new derivation and careful step-by-step anatomy. The result proves that even though both adding and subtracting a small volume appear to twist the original boundary, only addition essentially modifies the original boundary and consequently modifies the physics of the original problem in a subtle way. The correct procedure is subtraction. We complete a new BEM theory by introducing in full analytical form what we call the singular stress tensor for the fundamental solution. We partition the stress tensor of the fundamental solution into a singular part and a regular part. In this way all singular integrals systematically shift into the easy singular stress tensor. Applications of this new BEM to deformation and gravitational perturbation induced by magma chambers of finite volume will be presented.

  7. Dark Higgs bosons at the ForwArd Search ExpeRiment

    NASA Astrophysics Data System (ADS)

    Feng, Jonathan L.; Galon, Iftah; Kling, Felix; Trojanowski, Sebastian

    2018-03-01

    FASER, ForwArd Search ExpeRiment at the LHC, has been proposed as a small, very far forward detector to discover new, light, weakly-coupled particles. Previous work showed that with a total volume of just ˜0.1 - 1 m3 , FASER can discover dark photons in a large swath of currently unconstrained parameter space, extending the discovery reach of the LHC program. Here we explore FASER's discovery prospects for dark Higgs bosons. These scalar particles are an interesting foil for dark photons, as they probe a different renormalizable portal interaction and are produced dominantly through B and K meson decays, rather than pion decays, leading to less collimated signals. Nevertheless, we find that FASER is also a highly sensitive probe of dark Higgs bosons with significant discovery prospects that are comparable to, and complementary to, much larger proposed experiments.

  8. Theoretical evaluation of scattering effect on retroreflective free-space optical communication.

    PubMed

    Yin, Hongwei; Lan, Tianpeng; Zhang, Hailiang; Jia, Honghui; Chang, Shengli; Yang, Juncai

    2012-12-01

    Retroreflective free-space optical (RFSO) communication is a new concept of optical communication; it consists of an optical transceiver and a retromodulator and has advantages such as light weight, small volume, and low power consumption. The power captured by the receiver consists of two parts: retroreflective and scattering. The retroreflective characteristics are obtained using an analytical formula, the scattering characteristics using a Monte Carlo model. Results show that the scattering power plays an important role in a RFSO communication link, especially when the communication range is long or the meteorological range is short. Some rules are also obtained for the sake of system design, which include increasing the range from the transmitter and the receiver properly, increasing the area of the retromodulator, limiting the field of view of the receiver, and limiting the beam divergence of the transmitter.

  9. The laser radiation action on the crystal formation processes in the biological fluids

    NASA Astrophysics Data System (ADS)

    Malov, Alexander N.; Vaichas, Andrey A.; Novikova, Evgeniya A.

    2016-11-01

    The results of an experimental study of the laser radiation effect on the crystal`s formation in the volume of biological fluids that are complex multi-component solutions have been discussing. Are investigated white and natural bile in vitro. The qualitative changes were observed. Thus, at the bottom of the cell in which bile is not exposed to the laser radiation, the crystals are formed. In the irradiated bile gallstone has a thin layer of a homogeneous viscous colloidal liquid with very small, visible in polarized light crystalline formations was got. Irradiated laser bile's gallstone was covered evenly white deposit without surface defect unlike gallstone in bile without radiation exposure. A possible mechanism to explain the laser radiation action on the mineral formation in biological fluids and also practical application of this effect have been suggesting too.

  10. Materials screening chamber for testing materials resistance to atomic oxygen

    NASA Technical Reports Server (NTRS)

    Pippin, H. G.; Carruth, Ralph

    1989-01-01

    A unique test chamber for exposing material to a known flux of oxygen atoms is described. The capabilities and operating parameters of the apparatus include production of an oxygen atom flux in excess of 5 x 10 to the 16th atoms/sq cm-sec, controlled heating of the sample specimen, RF circuitry to contain the plasma within a small volume, and long exposure times. Flux measurement capabilities include a calorimetric probe and a light titration system. Accuracy and limitations of these techniques are discussed. An extension to the main chamber to allow simultaneous ultraviolet and atomic oxygen exposure is discussed. The oxygen atoms produced are at thermal energies. Sample specimens are maintained at any selected temperature between ambient and 200 C, to within + or - 2 C. A representative example of measurements made using the chamber is presented.

  11. Optical data transmission technology for fixed and drag-on STS payloads umbilicals. Volume 1: Executive summary

    NASA Technical Reports Server (NTRS)

    St.denis, R. W.

    1981-01-01

    The feasibility of using optical data handling methods to transmit payload checkout and telemetry is discussed. Optical communications are superior to conventional communication systems for the following reasons: high data capacity optical channels; small and light weight optical cables; and optical signal immunity to electromagnetic interference. Task number one analyzed the ground checkout data requirements that may be expected from the payload community. Task number two selected the optical approach based on the interface requirements, the location of the interface, the amount of time required to reconfigure hardware, and the method of transporting the optical signal. Task number three surveyed and selected optical components for the two payload data link. Task number four makes a qualitative comparison of the conventional electrical communication system and the proposed optical communication system.

  12. Miniature interferometer for refractive index measurement in microfluidic chip

    NASA Astrophysics Data System (ADS)

    Chen, Minghui; Geiser, Martial; Truffer, Frederic; Song, Chengli

    2012-12-01

    The design and development of the miniaturized interferometer for measurement of the refractive index or concentration of sub-microliter volume aqueous solution in microfludic chip is presented. It is manifested by a successful measurement of the refractive index of sugar-water solution, by utilizing a laser diode for light source and the small robust instrumentation for practical implementation. Theoretically, the measurement principle and the feasibility of the system are analyzed. Experimental device is constructed with a diode laser, lens, two optical plate and a complementary metal oxide semiconductor (CMOS). Through measuring the positional changes of the interference fringes, the refractive index change are retrieved. A refractive index change of 10-4 is inferred from the measured image data. The entire system is approximately the size of half and a deck of cards and can operate on battery power for long time.

  13. [A micro-silicon multi-slit spectrophotometer based on MEMS technology].

    PubMed

    Hao, Peng; Wu, Yi-Hui; Zhang, Ping; Liu, Yong-Shun; Zhang, Ke; Li, Hai-Wen

    2009-06-01

    A new mini-spectrophotometer was developed by adopting micro-silicon slit and pixel segmentation technology, and this spectrophotometer used photoelectron diode array as the detector by the back-dividing-light way. At first, the effect of the spectral bandwidth on the tested absorbance linear correlation was analyzed. A theory for the design of spectrophotometer's slit was brought forward after discussing the relationships between spectrophotometer spectrum band width and pre-and post-slits width. Then, the integrative micro-silicon-slit, which features small volume, high precision, and thin thickness, was manufactured based on the MEMS technology. Finally, a test was carried on linear absorbance solution by this spectrophotometer. The final result showed that the correlation coefficients were larger than 0.999, which means that the new mini-spectrophotometer with micro-silicon slit pixel segmentation has an obvious linear correlation.

  14. Nonlinear response of silicon photonic crystal microresonators excited via an integrated waveguide and fiber taper.

    PubMed

    Barclay, Paul; Srinivasan, Kartik; Painter, Oskar

    2005-02-07

    A technique is demonstrated which efficiently transfers light between a tapered standard single-mode optical fiber and a high-Q, ultra-small mode volume, silicon photonic crystal resonant cavity. Cavity mode quality factors of 4.7x10(4) are measured, and a total fiber-to-cavity coupling efficiency of 44% is demonstrated. Using this efficient cavity input and output channel, the steady-state nonlinear absorption and dispersion of the photonic crystal cavity is studied. Optical bistability is observed for fiber input powers as low as 250 microW, corresponding to a dropped power of 100 microW and 3 fJ of stored cavity energy. A high-density effective free-carrier lifetime for these silicon photonic crystal resonators of ~ 0.5 ns is also estimated from power dependent loss and dispersion measurements.

  15. Effect of acute heat stress on rat adrenal glands: a morphological and stereological study.

    PubMed

    Koko, Vesna; Djordjeviae, Jelena; Cvijiae, Gordana; Davidoviae, Vukosava

    2004-11-01

    The morphological and stereological structure of rat adrenal gland was analysed by light microscopy after an acute (60 min) exposure to high ambient temperature (38 degrees C). A significant increase in plasma corticotrophin (ACTH) and serum corticosterone (CORT) concentrations was observed, confirming that acute heat exposure has a strong stressful effect. Under these conditions the adrenal gland mass and volume were decreased, probably as the consequence of adrenal cortex reduction, especially that of the zona fasciculata (ZF). Histological examination revealed that many ZF cells were deprived of lipid droplets. Fibrosis was observed in all parts of the adrenal gland, both cortex and medulla, of heat stressed animals. Mitotic figures were absent in cortical cells after heat exposure, but there were no differences in ZF and zona reticularis (ZR) small blood vessels compared to nonstressed controls.

  16. Effects of multi-well plate incubation on embryo-larval development in the fathead minnow (Pimephales promelas).

    PubMed

    Marentette, Julie R; Sullivan, Cheryl A; Lavalle, Christine; Shires, Kallie; Parrott, Joanne L

    2015-01-01

    Fathead minnow embryos and larvae are frequently used in toxicology, including short-term embryo-only tests which often use small volumes of test solution. The effect that such conditions may have on fathead minnow development has yet to be explicitly described. Here we compared rates of embryonic development in fathead minnow embryos reared under standard light and temperature conditions with a range of possible methods. All methods yielded excellent control survival. We demonstrated that fathead minnow embryos incubated in a range of small volumes in multi-well plates (500 μL to 2 mL per embryo) did not substantially vary in developmental rate, but flexed less frequently as embryos, hatched smaller, later and with larger yolk-sacs, and initiated feeding later than embryos reared in an excess of solution (20 mL per embryo) with or without supplemental aeration. Faster hatch and growth were promoted with an orbital shaker, but growth benefits were not sustained into the larval stage. Developmental differences persisted in larvae reared to 20 days post-fertilization when monitoring ceased, but growth differences did not magnify and in some measurements partially resolved. To our knowledge we are the first to report effects of incubation in multi-well plates in any fish taxa. As our data revealed that the eleutheroembryonic stage for fathead minnow may be prolonged in multi-well plates, this may allow the use of longer toxicity tests using fathead minnow embryos without conflicting with existing animal welfare legislation in many countries. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.

  17. Vertical nanopillars for highly localized fluorescence imaging

    PubMed Central

    Xie, Chong; Hanson, Lindsey; Cui, Yi; Cui, Bianxiao

    2011-01-01

    Observing individual molecules in a complex environment by fluorescence microscopy is becoming increasingly important in biological and medical research, for which critical reduction of observation volume is required. Here, we demonstrate the use of vertically aligned silicon dioxide nanopillars to achieve below-the-diffraction-limit observation volume in vitro and inside live cells. With a diameter much smaller than the wavelength of visible light, a transparent silicon dioxide nanopillar embedded in a nontransparent substrate restricts the propagation of light and affords evanescence wave excitation along its vertical surface. This effect creates highly confined illumination volume that selectively excites fluorescence molecules in the vicinity of the nanopillar. We show that this nanopillar illumination can be used for in vitro single-molecule detection at high fluorophore concentrations. In addition, we demonstrate that vertical nanopillars interface tightly with live cells and function as highly localized light sources inside the cell. Furthermore, specific chemical modification of the nanopillar surface makes it possible to locally recruit proteins of interest and simultaneously observe their behavior within the complex, crowded environment of the cell. PMID:21368157

  18. Improvable method for Halon 1301 concentration measurement based on infrared absorption

    NASA Astrophysics Data System (ADS)

    Hu, Yang; Lu, Song; Guan, Yu

    2015-09-01

    Halon 1301 has attached much interest because of its pervasive use as an effective fire suppressant agent in aircraft related fires, and the study of fire suppressant agent concentration measurement is especially of interest. In this work, a Halon 1301 concentration measurement method based on the Beer-Lambert law is developed. IR light is transmitted through mixed gas, and the light intensity with and without the agent present is measured. The intensity ratio is a function of the volume percentage of Halon 1301, and the voltage output of the detector is proportional to light intensity. As such, the relationship between the volume percentage and voltage ratio can be established. The concentration measurement system shows a relative error of the system less than ±2.50%, and a full scale error within 1.20%. This work also discusses the effect of temperature and relative humidity (RH) on the calibration. The experimental results of voltage ratio versus Halon 1301 volume percentage relationship show that the voltage ratio drops significantly as temperature rises from 25 to 100 °C, and it decreases as RH rises from 0% to 100%.

  19. Echocardiography underestimates stroke volume and aortic valve area: implications for patients with small-area low-gradient aortic stenosis.

    PubMed

    Chin, Calvin W L; Khaw, Hwan J; Luo, Elton; Tan, Shuwei; White, Audrey C; Newby, David E; Dweck, Marc R

    2014-09-01

    Discordance between small aortic valve area (AVA; < 1.0 cm(2)) and low mean pressure gradient (MPG; < 40 mm Hg) affects a third of patients with moderate or severe aortic stenosis (AS). We hypothesized that this is largely due to inaccurate echocardiographic measurements of the left ventricular outflow tract area (LVOTarea) and stroke volume alongside inconsistencies in recommended thresholds. One hundred thirty-three patients with mild to severe AS and 33 control individuals underwent comprehensive echocardiography and cardiovascular magnetic resonance imaging (MRI). Stroke volume and LVOTarea were calculated using echocardiography and MRI, and the effects on AVA estimation were assessed. The relationship between AVA and MPG measurements was then modelled with nonlinear regression and consistent thresholds for these parameters calculated. Finally the effect of these modified AVA measurements and novel thresholds on the number of patients with small-area low-gradient AS was investigated. Compared with MRI, echocardiography underestimated LVOTarea (n = 40; -0.7 cm(2); 95% confidence interval [CI], -2.6 to 1.3), stroke volumes (-6.5 mL/m(2); 95% CI, -28.9 to 16.0) and consequently, AVA (-0.23 cm(2); 95% CI, -1.01 to 0.59). Moreover, an AVA of 1.0 cm(2) corresponded to MPG of 24 mm Hg based on echocardiographic measurements and 37 mm Hg after correction with MRI-derived stroke volumes. Based on conventional measures, 56 patients had discordant small-area low-gradient AS. Using MRI-derived stroke volumes and the revised thresholds, a 48% reduction in discordance was observed (n = 29). Echocardiography underestimated LVOTarea, stroke volume, and therefore AVA, compared with MRI. The thresholds based on current guidelines were also inconsistent. In combination, these factors explain > 40% of patients with discordant small-area low-gradient AS. Copyright © 2014 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  20. Improving the axial resolution in time-reversed ultrasonically encoded (TRUE) optical focusing with dual ultrasonic waves

    NASA Astrophysics Data System (ADS)

    Yang, Qiang; Xu, Xiao; Lai, Puxiang; Sang, Xinzhu; Wang, Lihong V.

    2014-03-01

    Focusing light inside highly scattering media beyond the ballistic regime is a challenging task in biomedical optical imaging, manipulation, and therapy. This challenge can be overcome by time reversing ultrasonically encoded (TRUE) diffuse light to the ultrasonic focus inside a turbid medium. In TRUE optical focusing, a photorefractive crystal or polymer is used as the phase conjugate mirror for optical time reversal. Accordingly, a relatively long ultrasound burst, whose duration matches the response time of the photorefractive material, is used to encode the diffuse light. With this long ultrasound burst, the resolution of the TRUE focus along the acoustic axis is poor. In this work, we used two transducers, emitting two intersecting ultrasound beams at 3.4 MHz and 3.6 MHz respectively, to modulate the diffuse light within their intersection volume at the beat frequency. We show that light encoded at the beat frequency can be time-reversed and converge to the intersection volume. Experimentally, TRUE focusing with an acoustic axial resolution of ~1.1 mm was demonstrated inside turbid media, agreeing with the theoretical estimation.

  1. Real-Time Analysis of Isoprene in Breath by Using Ultraviolet-Absorption Spectroscopy with a Hollow Optical Fiber Gas Cell

    PubMed Central

    Iwata, Takuro; Katagiri, Takashi; Matsuura, Yuji

    2016-01-01

    A breath analysis system based on ultraviolet-absorption spectroscopy was developed by using a hollow optical fiber as a gas cell for real-time monitoring of isoprene in breath. The hollow optical fiber functions as an ultra-small-volume gas cell with a long path. The measurement sensitivity of the system was evaluated by using nitric-oxide gas as a gas sample. The evaluation result showed that the developed system, using a laser-driven, high-intensity light source and a 3-m-long, aluminum-coated hollow optical fiber, could successfully measure nitric-oxide gas with a 50 ppb concentration. An absorption spectrum of a breath sample in the wavelength region of around 200–300 nm was measured, and the measured spectrum revealed the main absorbing components in breath as water vapor, isoprene, and ozone converted from oxygen by radiation of ultraviolet light. The concentration of isoprene in breath was estimated by multiple linear regression. The regression analysis results showed that the proposed analysis system enables real-time monitoring of isoprene during the exhaling of breath. Accordingly, it is suitable for measuring the circadian variation of isoprene. PMID:27929387

  2. Lung dosimetry for inhaled radon progeny in smokers.

    PubMed

    Baias, Paul F; Hofmann, Werner; Winkler-Heil, Renate; Cosma, Constantin; Duliu, Octavian G

    2010-02-01

    Cigarette smoking may change the morphological and physiological parameters of the lung. Thus the primary objective of the present study was to investigate to what extent these smoke-induced changes can modify deposition, clearance and resulting doses of inhaled radon progeny relative to healthy non-smokers (NSs). Doses to sensitive bronchial target cells were computed for four categories of smokers: (1) Light, short-term (LST) smokers, (2) light, long-term (LLT) smokers, (3) heavy, short-term (HST) smokers and (4) heavy, long-term (HLT) smokers. Because of only small changes of morphological and physiological parameters, doses for the LST smokers hardly differed from those for NSs. For LLT and HST smokers, even a protective effect could be observed, caused by a thicker mucus layer and increased mucus velocities. Only in the case of HLT smokers were doses higher by about a factor of 2 than those for NSs, caused primarily by impaired mucociliary clearance, higher breathing frequency, reduced lung volume and airway obstructions. These higher doses suggest that the contribution of inhaled radon progeny to the risk of lung cancer in smokers may be higher than currently assumed on the basis of NS doses.

  3. Photoluminescence Spectra From The Direct Energy Gap of a-SiQDs

    NASA Astrophysics Data System (ADS)

    Abdul-Ameer, Nidhal M.; Abdulrida, Moafak C.; Abdul-Hakeem, Shatha M.

    2018-05-01

    A theoretical model for radiative recombination in amorphous silicon quantum dots (a-SiQDs) was developed. In this model, for the first time, the coexistence of both spatial and quantum confinements were considered. Also, it is found that the photoluminescence exhibits significant size dependence in the range (1-4) nm of the quantum dots. a-SiQDs show visible light emission peak energies and high radiative quantum efficiency at room temperature,in contrast to bulk a-Si structures. The quantum efficiency is sensitive to any change in defect density (the volume nonradiative centers density and/or the surface nonradiative centers density) but, with small dots sizes, the quantum efficiency is insensitive to such defects. Our analysis shows that the photoluminescence intensity increases or decreases by the effect of radiative quantum efficiency. By controlling the size of a-SiQDs, we note that the energy of emission can be tuned. The blue shift is attributed to quantum confinement effect. Meanwhile, the spatial confinement effect is clearly observed in red shift in emission spectra. we found a good agreement with the experimental published data. Therefore, we assert that a-SiQDs material is a promising candidate for visible, tunable, and high performance devices of light emitting.

  4. Heterogeneous vesiculation of 2011 El Hierro xeno-pumice revealed by X-ray computed microtomography

    NASA Astrophysics Data System (ADS)

    Berg, S. E.; Troll, V. R.; Deegan, F. M.; Burchardt, S.; Krumbholz, M.; Mancini, L.; Polacci, M.; Carracedo, J. C.; Soler, V.; Arzilli, F.; Brun, F.

    2016-12-01

    During the first week of the 2011 El Hierro submarine eruption, abundant light-coloured pumiceous, high-silica volcanic bombs coated in dark basanite were found floating on the sea. The composition of the light-coloured frothy material (`xeno-pumice') is akin to that of sedimentary rocks from the region, but the textures resemble felsic magmatic pumice, leaving their exact mode of formation unclear. To help decipher their origin, we investigated representative El Hierro xeno-pumice samples using X-ray computed microtomography for their internal vesicle shapes, volumes, and bulk porosity, as well as for the spatial arrangement and size distributions of vesicles in three dimensions (3D). We find a wide range of vesicle morphologies, which are especially variable around small fragments of rock contained in the xeno-pumice samples. Notably, these rock fragments are almost exclusively of sedimentary origin, and we therefore interpret them as relicts an the original sedimentary ocean crust protolith(s). The irregular vesiculation textures observed probably resulted from pulsatory release of volatiles from multiple sources during xeno-pumice formation, most likely by successive release of pore water and mineral water during incremental heating and decompression of the sedimentary protoliths.

  5. Relationship between position of brain activity and change in optical density for NIR imaging

    NASA Astrophysics Data System (ADS)

    Kashio, Yoshihiko; Ono, Muneo; Firbank, Michael; Schweiger, Martin; Arridge, Simon R.; Okada, Eiji

    2000-11-01

    Multi-channel NIR system can obtain the topographic image of brain activity. Since the image is reconstructed from the change in optical density measured with the source-detector pairs, it is important to reveal the volume of tissue sampled by each source-detector pair. In this study, the light propagation in three-dimensional adult head model is calculated by hybrid radiosity-diffusion method. The model is a layered slab which mimics the extra cerebral tissue (skin, skull), CSF and brain. The change in optical density caused by the absorption change in a small cylindrical region of 10 mm in diameter at various positions in the brain is calculated. The greatest change in optical density can be observed when the absorber is located in the middle of the source and detector. When the absorber is located just below the source or detector, the change in optical density is almost half of that caused by the same absorber in the midpoint. The light propagation in the brain is strongly affected by the presence of non-scattering layer and consequently sensitive region is broadly distributed on the brain surface.

  6. Full 3D opto-electronic simulation tool for nanotextured solar cells (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Michallon, Jérôme; Collin, Stéphane

    2017-04-01

    Increasing efforts on the photovoltaics research have recently been devoted to material savings, leading to the emergence of new designs based on nanotextured and nanowire-based solar cells. The use of small absorber volumes, light-trapping nanostructures and unconventional carrier collection schemes (radial nanowire junctions, point contacts in planar structures,…) increases the impact of surfaces recombination and induces homogeneity in the photogenerated carrier concentrations. The investigation of their impacts on the device performances need to be addressed using full 3D coupled opto-electrical modeling. In this context, we have developed a new tool for full 3D opto-electrical simulation using the most advanced optical and electrical simulation techniques. We will present an overview of its simulation capabilities and the key issues that have been solved to make it fully operational and reliable. We will provide various examples of opto-electronic simulation of (i) nanostructured solar cells with localized contacts and (ii) nanowire solar cells. We will also show how opto-electronic simulation can be used to simulate light- and electron-beam induced current (LBIC/EBIC) experiments, targeting quantitative analysis of the passivation properties of surfaces.

  7. Calocube-A highly segmented calorimeter for a space based experiment

    NASA Astrophysics Data System (ADS)

    D`Alessandro, R.; Adriani, O.; Agnesi, A.; Albergo, S.; Auditore, L.; Basti, A.; Berti, E.; Bigongiari, G.; Bonechi, L.; Bonechi, S.; Bongi, M.; Bonvicini, V.; Bottai, S.; Brogi, P.; Carotenuto, G.; Castellini, G.; Cattaneo, P. W.; Cauz, D.; Chiari, M.; Daddi, N.; Detti, S.; Fasoli, M.; Finetti, N.; Gregorio, A.; Lenzi, P.; Maestro, P.; Marrocchesi, P. S.; Miritello, M.; Mori, N.; Pacini, L.; Papini, P.; Pauletta, G.; Pirzio, F.; Rappazzo, G. F.; Rappoldi, A.; Ricciarini, S.; Santi, L. G.; Spillantini, P.; Starodubtsev, O.; Suh, J. E.; Sulaj, A.; Tiberio, A.; Tricomi, A.; Trifiro, A.; Trimarchi, M.; Vannuccini, E.; Vedda, A.; Zampa, G.; Zampa, N.; Zerbo, B.

    2016-07-01

    Future research in High Energy Cosmic Ray Physics concerns fundamental questions on their origin, acceleration mechanism, and composition. Unambiguous measurements of the energy spectra and of the composition of cosmic rays at the "knee" region could provide some of the answers to the above questions. Only ground based observations, which rely on sophisticated models describing high energy interactions in the earth's atmosphere, have been possible so far due to the extremely low particle rates at these energies. A calorimeter based space experiment can provide not only flux measurements but also energy spectra and particle identification, especially when coupled to a dE/dx measuring detector, and thus overcome some of the limitations plaguing ground based experiments. For this to be possible very large acceptances are needed if enough statistic is to be collected in a reasonable time. This contrasts with the lightness and compactness requirements for space based experiments. A novel idea in calorimetry is discussed here which addresses these issues while limiting the mass and volume of the detector. In fact a small prototype is currently being built and tested with ions. In this paper the results obtained will be presented in light of the simulations performed.

  8. Real-Time Analysis of Isoprene in Breath by Using Ultraviolet-Absorption Spectroscopy with a Hollow Optical Fiber Gas Cell.

    PubMed

    Iwata, Takuro; Katagiri, Takashi; Matsuura, Yuji

    2016-12-05

    A breath analysis system based on ultraviolet-absorption spectroscopy was developed by using a hollow optical fiber as a gas cell for real-time monitoring of isoprene in breath. The hollow optical fiber functions as an ultra-small-volume gas cell with a long path. The measurement sensitivity of the system was evaluated by using nitric-oxide gas as a gas sample. The evaluation result showed that the developed system, using a laser-driven, high-intensity light source and a 3-m-long, aluminum-coated hollow optical fiber, could successfully measure nitric-oxide gas with a 50 ppb concentration. An absorption spectrum of a breath sample in the wavelength region of around 200-300 nm was measured, and the measured spectrum revealed the main absorbing components in breath as water vapor, isoprene, and ozone converted from oxygen by radiation of ultraviolet light. The concentration of isoprene in breath was estimated by multiple linear regression. The regression analysis results showed that the proposed analysis system enables real-time monitoring of isoprene during the exhaling of breath. Accordingly, it is suitable for measuring the circadian variation of isoprene.

  9. Object strength--an accurate measure for small objects that is insensitive to partial volume effects.

    PubMed

    Tofts, P S; Silver, N C; Barker, G J; Gass, A

    2005-07-01

    There are currently four problems in characterising small nonuniform lesions or other objects in Magnetic Resonance images where partial volume effects are significant. Object size is over- or under-estimated; boundaries are often not reproducible; mean object value cannot be measured; and fuzzy borders cannot be accommodated. A new measure, Object Strength, is proposed. This is the sum of all abnormal intensities, above a uniform background value. For a uniform object, this is simply the product of the increase in intensity and the size of the object. Biologically, this could be at least as relevant as existing measures of size or mean intensity. We hypothesise that Object Strength will perform better than traditional area measurements in characterising small objects. In a pilot study, the reproducibility of object strength measurements was investigated using MR images of small multiple sclerosis (MS) lesions. In addition, accuracy was investigated using artificial lesions of known volume (0.3-6.2 ml) and realistic appearance. Reproducibility approached that of area measurements (in 33/90 lesion reports the difference between repeats was less than for area measurements). Total lesion volume was accurate to 0.2%. In conclusion, Object Strength has potential for improved characterisation of small lesions and objects in imaging and possibly spectroscopy.

  10. Structure-property evolution during polymer crystallization

    NASA Astrophysics Data System (ADS)

    Arora, Deepak

    The main theme of this research is to understand the structure-property evolution during crystallization of a semicrystalline thermoplastic polymer. A combination of techniques including rheology, small angle light scattering, differential scanning calorimetry and optical microscopy are applied to follow the mechanical and optical properties along with crystallinity and the morphology. Isothermal crystallization experiments on isotactic poly-1-butene at early stages of spherulite growth provide quantitative information about nucleation density, volume fraction of spherulites and their crystallinity, and the mechanism of connecting into a sample spanning structure. Optical microscopy near the fluid-to-solid transition suggests that the transition, as determined by time-resolved mechanical spectroscopy, is not caused by packing/jamming of spherulites but by the formation of a percolating network structure. The effect of strain, Weissenberg number (We ) and specific mechanical work (w) on rate of crystallization (nucleation followed by growth) and on growth of anisotropy was studied for shear-induced crystallization of isotactic poly-1-butene. The samples were sheared for a finite strain at the beginning of the experiment and then crystallized without further flow (Janeschitz-Kriegl protocol). Strain requirements to attain steady state/leveling off of the rate of crystallization were found to be much larger than the strain needed to achieve steady state of flow. The large strain and We>1 criteria were also observed for morphological transition from spherulitic growth to oriented growth. An apparatus for small angle light scattering (SALS) and light transmission measurements under shear was built and tested at the University of Massachusetts Amherst. As a new development, the polarization direction can be rotated by a liquid crystal polarization rotator (LCPR) with a short response time of 20 ms. The experiments were controlled and analyzed with a LabVIEW(TM) based code (LabVIEW(TM) 7.1) in real time. The SALS apparatus was custom built for ExxonMobil Research in Clinton NJ.

  11. Highway Vehicle Retrofit Evaluation : Phase I. Analysis and Preliminary Evaluation Results. Volume 1. Sections 1 through 3.

    DOT National Transportation Integrated Search

    1975-11-01

    This report in two volumes presents an analysis and preliminary evaluation of selected used-car and light-truck fuel economy retrofit devices. In particular, information is provided that depicts the performance characteristics of retrofit devices tha...

  12. Computational Modeling to Limit the Impact Displays and Indicator Lights Have on Habitable Volume Operational Lighting Constraints

    NASA Technical Reports Server (NTRS)

    Clark, T. A.; Brainard, G.; Salazar, G.; Johnston, S.; Schwing, B.; Litaker, H.; Kolomenski, A.; Venus, D.; Tran, K.; Hanifin, J.; hide

    2017-01-01

    NASA has demonstrated an interest in improving astronaut health and performance through the installment of a new lighting countermeasure on the International Space Station. The Solid State Lighting Assembly (SSLA) system is designed to positively influence astronaut health by providing a daily change to light spectrum to improve circadian entrainment. Unfortunately, existing NASA standards and requirements define ambient light level requirements for crew sleep and other tasks, yet the number of light-emitting diode (LED) indicators and displays within a habitable volume is currently uncontrolled. Because each of these light sources has its own unique spectral properties, the additive lighting environment ends up becoming something different from what was planned or researched. Restricting the use of displays and indicators is not a solution because these systems provide beneficial feedback to the crew. The research team for this grant used computer-based computational modeling and real-world lighting mockups to document the impact that light sources other than the ambient lighting system contribute to the ambient spectral lighting environment. In particular, the team was focused on understanding the impacts of long-term tasks located in front of avionics or computer displays. The team also wanted to understand options for mitigating the changes to the ambient light spectrum in the interest of maintaining the performance of a lighting countermeasure. The project utilized a variety of physical and computer-based simulations to determine direct relationships between system implementation and light spectrum. Using real-world data, computer models were built in the commercially available optics analysis software Zemax Optics Studio(c). The team also built a mockup test facility that had the same volume and configuration as one of the Zemax models. The team collected over 1200 spectral irradiance measurements, each representing a different configuration of the mockup. Analysis of the data showed a measurable impact on ambient light spectrum. This data showed that obvious design techniques exist that can be used to bind the ambient light spectrum closer to the planned spectral operating environment for the observer's eye point. The following observations should be considered when designing an operational environment that is dominated by computer displays. When more light is directed into the field of view of the observer, the greater the impact it will make on various human factors issues that depend on spectral shape and intensity. Because viewing angle has a large part to play in the amount of light flux on the crewmember's retina, beam shape, combined with light source location is an important factor for determining percent probable incident flux on the observer from any combination of light sources. Computer graphics design and display lumen output are major factors influencing the amount of spectrally intense light projected into the environment and in the viewer's direction. Use of adjustable white point display software was useful only if the predominant background color was white and if it matched the ambient light system's color. Display graphics that used a predominantly black background had the least influence on unplanned spectral energy projected into the environment. Percent reflectance makes a difference in total energy reflected back into an environment, and within certain architectural geometries, reflectance can be used to control the amount of a light spectrum that is allowed to perpetuate in the environment. Data showed that room volume and distance from significant light sources influence the total spectrum in a room. Smaller environments had a homogenizing effect on total light spectrum, whereas light from multiple sources in larger environments was less mixed. The findings indicated above should be considered when making recommendations for practice or standards for architectural systems. The ambient lighting system, surface reflectance, and display and indicator implementation all factor into the users' spectral environment. A variety of low-cost solutions exist to mitigate the impact of light from non-architectural lighting systems, and much potential for system automation and integration of display systems with the ambient environment. This team believes that proper planning can be used to avoid integration problems and also believes that human-in-the-loop evaluations, real-world test and measurement, and computer modeling can be used to determine how changes to a process, display graphics, and architecture will help maintain the planned spectral operating lighting environment.

  13. 40 CFR 1051.625 - What special provisions apply to unique snowmobile designs for small-volume manufacturers?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false What special provisions apply to unique snowmobile designs for small-volume manufacturers? 1051.625 Section 1051.625 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM RECREATIONAL ENGINES AND VEHICLES Compliance...

  14. Osmotic virial coefficients for model protein and colloidal solutions: importance of ensemble constraints in the analysis of light scattering data.

    PubMed

    Siderius, Daniel W; Krekelberg, William P; Roberts, Christopher J; Shen, Vincent K

    2012-05-07

    Protein-protein interactions in solution may be quantified by the osmotic second virial coefficient (OSVC), which can be measured by various experimental techniques including light scattering. Analysis of Rayleigh light scattering measurements from such experiments requires identification of a scattering volume and the thermodynamic constraints imposed on that volume, i.e., the statistical mechanical ensemble in which light scattering occurs. Depending on the set of constraints imposed on the scattering volume, one can obtain either an apparent OSVC, A(2,app), or the true thermodynamic OSVC, B(22)(osm), that is rigorously defined in solution theory [M. A. Blanco, E. Sahin, Y. Li, and C. J. Roberts, J. Chem. Phys. 134, 225103 (2011)]. However, it is unclear to what extent A(2,app) and B(22)(osm) differ, which may have implications on the physical interpretation of OSVC measurements from light scattering experiments. In this paper, we use the multicomponent hard-sphere model and a well-known equation of state to directly compare A(2,app) and B(22)(osm). Our results from the hard-sphere equation of state indicate that A(2,app) underestimates B(22)(osm), but in a systematic manner that may be explained using fundamental thermodynamic expressions for the two OSVCs. The difference between A(2,app) and B(22)(osm) may be quantitatively significant, but may also be obscured in experimental application by statistical uncertainty or non-steric interactions. Consequently, the two OSVCs that arise in the analysis of light scattering measurements do formally differ, but in a manner that may not be detectable in actual application.

  15. Treatment planning and dose analysis for interstitial photodynamic therapy of prostate cancer

    NASA Astrophysics Data System (ADS)

    Davidson, Sean R. H.; Weersink, Robert A.; Haider, Masoom A.; Gertner, Mark R.; Bogaards, Arjen; Giewercer, David; Scherz, Avigdor; Sherar, Michael D.; Elhilali, Mostafa; Chin, Joseph L.; Trachtenberg, John; Wilson, Brian C.

    2009-04-01

    With the development of new photosensitizers that are activated by light at longer wavelengths, interstitial photodynamic therapy (PDT) is emerging as a feasible alternative for the treatment of larger volumes of tissue. Described here is the application of PDT treatment planning software developed by our group to ensure complete coverage of larger, geometrically complex target volumes such as the prostate. In a phase II clinical trial of TOOKAD vascular targeted photodynamic therapy (VTP) for prostate cancer in patients who failed prior radiotherapy, the software was used to generate patient-specific treatment prescriptions for the number of treatment fibres, their lengths, their positions and the energy each delivered. The core of the software is a finite element solution to the light diffusion equation. Validation against in vivo light measurements indicated that the software could predict the location of an iso-fluence contour to within approximately ±2 mm. The same software was used to reconstruct the treatments that were actually delivered, thereby providing an analysis of the threshold light dose required for TOOKAD-VTP of the post-irradiated prostate. The threshold light dose for VTP-induced prostate damage, as measured one week post-treatment using contrast-enhanced MRI, was found to be highly heterogeneous, both within and between patients. The minimum light dose received by 90% of the prostate, D90, was determined from each patient's dose-volume histogram and compared to six-month sextant biopsy results. No patient with a D90 less than 23 J cm-2 had complete biopsy response, while 8/13 (62%) of patients with a D90 greater than 23 J cm-2 had negative biopsies at six months. The doses received by the urethra and the rectal wall were also investigated.

  16. SU-G-IeP4-11: Monitoring Tumor Growth in Subcutaneous Murine Tumor Model in Vivo: A Comparison Between MRI and Small Animal CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, B; He, W; Cvetkovic, D

    Purpose: The purpose of the study is to compare the volume measurement of subcutaneous tumors in mice with different imaging platforms, namely a GE MRI and a Sofie-Biosciences small animal CT scanner. Methods: A549 human lung carcinoma cells and FaDu human head and neck squamous cell carcinoma cells were implanted subcutaneously into flanks of nude mice. Three FaDu tumors and three A549 tumors were included in this study. The MRI scans were done with a GE Signa 1.5 Tesla MR scanner using a fast T2-weighted sequence (70mm FOV and 1.2mm slice thickness), while the CT scans were done with themore » CT scanner on a Sofie-Biosciences G8 PET/CT platform dedicated for small animal studies (48mm FOV and 0.2mm slice thickness). Imaging contrast agent was not used in this study. Based on the DICOM images from MRI and CT scans, the tumors were contoured with Philips DICOM Viewer and the tumor volumes were obtained by summing up the contoured area and multiplied by the slice thickness. Results: The volume measurements based on the CT scans agree reasonably with that obtained with MR images for the subcutaneous tumors. The mean difference in the absolute tumor volumes between MRI- and CT-based measurements was found to be −6.2% ± 1.0%, with the difference defined as (VMR – VCT)*100%/VMR. Furthermore, we evaluated the normalized tumor volumes, which were defined for each tumor as V/V{sub 0} where V{sub 0} stands for the volume from the first MR or CT scan. The mean difference in the normalized tumor volumes was found to be 0.10% ± 0.96%. Conclusion: Despite the fact that the difference between normal and abnormal tissues is often less clear on small animal CT images than on MR images, one can still obtain reasonable tumor volume information with the small animal CT scans for subcutaneous murine xenograft models.« less

  17. Defense Small Business Innovation Research Program (SBIR) FY 1983.

    DTIC Science & Technology

    1983-05-31

    matching networks for application in the frequency band below 30 MHz. The antenna should be light - weight, rapidly erectable and capable of operation while...munitions concealed within this terrain. m. More Efficient Utilization of Fuel in Light Trucks and Off-Road Vehi- cles (11) Current research is focusing on...affixed. The material must be light - * weight, small, and inexpensive to buy and install. d. Hard Coatings for Optical Systems (7) Broadband sensors

  18. Exceptional points enhance sensing in an optical microcavity

    NASA Astrophysics Data System (ADS)

    Chen, Weijian; Kaya Özdemir, Şahin; Zhao, Guangming; Wiersig, Jan; Yang, Lan

    2017-08-01

    Sensors play an important part in many aspects of daily life such as infrared sensors in home security systems, particle sensors for environmental monitoring and motion sensors in mobile phones. High-quality optical microcavities are prime candidates for sensing applications because of their ability to enhance light-matter interactions in a very confined volume. Examples of such devices include mechanical transducers, magnetometers, single-particle absorption spectrometers, and microcavity sensors for sizing single particles and detecting nanometre-scale objects such as single nanoparticles and atomic ions. Traditionally, a very small perturbation near an optical microcavity introduces either a change in the linewidth or a frequency shift or splitting of a resonance that is proportional to the strength of the perturbation. Here we demonstrate an alternative sensing scheme, by which the sensitivity of microcavities can be enhanced when operated at non-Hermitian spectral degeneracies known as exceptional points. In our experiments, we use two nanoscale scatterers to tune a whispering-gallery-mode micro-toroid cavity, in which light propagates along a concave surface by continuous total internal reflection, in a precise and controlled manner to exceptional points. A target nanoscale object that subsequently enters the evanescent field of the cavity perturbs the system from its exceptional point, leading to frequency splitting. Owing to the complex-square-root topology near an exceptional point, this frequency splitting scales as the square root of the perturbation strength and is therefore larger (for sufficiently small perturbations) than the splitting observed in traditional non-exceptional-point sensing schemes. Our demonstration of exceptional-point-enhanced sensitivity paves the way for sensors with unprecedented sensitivity.

  19. Effects of temperature and moisture on Mormon cricket reproduction with implications for responses to climate change.

    PubMed

    Srygley, Robert B

    2014-06-01

    During the last decade, populations of flightless Mormon crickets Anabrus simplex (Orthoptera: Tettigoniidae) increased suddenly over vast areas of the Western United States, suggesting that climate is an important factor driving outbreaks. Moreover summer temperatures are predicted to increase and precipitation is expected to decrease in most areas of the U.S. Great Basin, but little is known of the response of Mormon crickets to changes in temperature and soil moisture. In a laboratory study, we varied ambient temperature and lighting and measured the propensity of mating pairs to mate, and the proportion of eggs that developed into embryos. We found that reproduction was optimal when ambient temperature reached 30°C and the insects were beneath broad-spectrum lights such that maternal body and soil temperatures reached 35°C. Fewer eggs that developed fully were laid when maternal body and soil temperatures reached 30°C or 37-39°C. We also varied initial soil moisture from 0% to 100% saturated and found that more eggs reached embryonic diapause when initial soil moisture was 25% or 50% of saturated volume. However more of the developed eggs hatched when treated in summer soils with 0-25% of saturated moisture. We conclude that small changes in temperature had large effects on reproduction, whereas large changes in moisture had very small effects on reproduction. This is the first report of Mormon crickets mating in a laboratory setting and laying eggs that hatched, facilitating further research on the role of maternal and embryonic environments in changes in population size. Published by Elsevier Ltd.

  20. Numerical optix: A time-domain simulator of fluorescent light diffusion in turbid medium

    NASA Astrophysics Data System (ADS)

    Ma, Guobin; Delorme, Jean-François; Guilman, Olga; Leblond, Frédéric; Khayat, Mario

    2007-02-01

    The interest in fluorescence imaging has increased steadily in the last decade. Using fluorescence techniques, it is feasible to visualize and quantify the function of genes and the expression of enzymes and proteins deep inside tissues. When applied to small animal research, optical imaging based on fluorescent marker probes can provide valuable information on the specificity and efficacy of drugs at reduced cost and with greater efficiency. Meanwhile, fluorescence techniques represent an important class of optical methods being applied to in vitro and in vivo biomedical diagnostics, towards noninvasive clinical applications, such as detecting and monitoring specific pathological and physiological processes. ART has developed a time domain in vivo small animal fluorescence imaging system, eXplore Optix. Using the measured time-resolved fluorescence signal, fluorophore location and concentration can be quickly estimated. Furthermore, the 3D distribution of fluorophore can be obtained by fluorescent diffusion tomography. To accurately analyze and interpret the measured fluorescent signals from tissue, complex theoretical models and algorithms are employed. We present here a numerical simulator of eXplore Optix. It generates virtual data under well-controlled conditions that enable us to test, verify, and improve our models and algorithms piecewise separately. The theoretical frame of the simulator is an analytical solution of the fluorescence diffusion equation. Compared to existing models, the coupling of fluorophores with finite volume size is taken into consideration. Also, the influences of fluorescent inclusions to excitation and emission light are both accounted for. The output results are compared to Monte-Carlo simulations.

  1. Clinical application of a light-pen computer system for quantitative angiography

    NASA Technical Reports Server (NTRS)

    Alderman, E. L.

    1975-01-01

    The paper describes an angiographic analysis system which uses a video disk for recording and playback, a light-pen for data input, minicomputer processing, and an electrostatic printer/plotter for hardcopy output. The method is applied to quantitative analysis of ventricular volumes, sequential ventriculography for assessment of physiologic and pharmacologic interventions, analysis of instantaneous time sequence of ventricular systolic and diastolic events, and quantitation of segmental abnormalities. The system is shown to provide the capability for computation of ventricular volumes and other measurements from operator-defined margins by greatly reducing the tedium and errors associated with manual planimetry.

  2. Light detection and the wavelength shifter deposition in DEAP-3600

    NASA Astrophysics Data System (ADS)

    Broerman, B.; Retière, F.

    2016-02-01

    The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) uses liquid argon as a target medium to perform a direct-detection dark matter search. The 3600 kg liquid argon target volume is housed in a spherical acrylic vessel and viewed by a surrounding array of photomultiplier tubes. Ionizing particles in the argon volume produce scintillation light which must be wavelength shifted to be detected by the photomultiplier tubes. Argon scintillation and wavelength shifting, along with details on the application of the wavelength shifter to the inner surface of the acrylic vessel are presented.

  3. Special Features of Light Absorption by the Dimer of Bilayer Microparticles

    NASA Astrophysics Data System (ADS)

    Geints, Yu. É.; Panina, E. K.; Zemlyanov, A. A.

    2018-05-01

    Results of numerical simulation of light absorption by the dimer of bilayer spherical particles consisting of a water core and a polymer shell absorbing radiation are presented. The spatial distribution and the amplitude characteristics of the volume density of the absorbed power are investigated. It is shown that for a certain spatial dimer configuration, the maximal achievable density of the absorbed power is realized. It is also established that for closely spaced microcapsules with high shell absorption indices, the total power absorbed in the dimer volume can increase in comparison with the radiation absorption by two insulated microparticles.

  4. A computer system for analysis and transmission of spirometry waveforms using volume sampling.

    PubMed

    Ostler, D V; Gardner, R M; Crapo, R O

    1984-06-01

    A microprocessor-controlled data gathering system for telemetry and analysis of spirometry waveforms was implemented using a completely digital design. Spirometry waveforms were obtained from an optical shaft encoder attached to a rolling seal spirometer. Time intervals between 10-ml volume changes (volume sampling) were stored. The digital design eliminated problems of analog signal sampling. The system measured flows up to 12 liters/sec with 5% accuracy and volumes up to 10 liters with 1% accuracy. Transmission of 10 waveforms took about 3 min. Error detection assured that no data were lost or distorted during transmission. A pulmonary physician at the central hospital reviewed the volume-time and flow-volume waveforms and interpretations generated by the central computer before forwarding the results and consulting with the rural physician. This system is suitable for use in a major hospital, rural hospital, or small clinic because of the system's simplicity and small size.

  5. Elimination of the light shift in rubidium gas cell frequency standards using pulsed optical pumping

    NASA Technical Reports Server (NTRS)

    English, T. C.; Jechart, E.; Kwon, T. M.

    1978-01-01

    Changes in the intensity of the light source in an optically pumped, rubidium, gas cell frequency standard can produce corresponding frequency shifts, with possible adverse effects on the long-term frequency stability. A pulsed optical pumping apparatus was constructed with the intent of investigating the frequency stability in the absence of light shifts. Contrary to original expectations, a small residual frequency shift due to changes in light intensity was experimentally observed. Evidence is given which indicates that this is not a true light-shift effect. Preliminary measurements of the frequency stability of this apparatus, with this small residual pseudo light shift present, are presented. It is shown that this pseudo light shift can be eliminated by using a more homogeneous C-field. This is consistent with the idea that the pseudo light shift is due to inhomogeneity in the physics package (position-shift effect).

  6. Plant Atrium System for Food Production in NASA's Deep Space Habitat Tests

    NASA Technical Reports Server (NTRS)

    Massa, Gioia; Simpson, Morgan S.; Newsham, Gerard; Stutte, Gary W.; Wheeler, Raymond M.

    2012-01-01

    In preparation for future human exploration missions to space, human habitat designs and concepts need to be tested to assess integration issues, power requirements, crew operations, and technology I subsystem performance. One potential subsystem for early habitats is supplemental food production. Fresh foods, such as vegetables and small fruits, could be harvested on a continuous basis to improve the diet and quality of life. The system would need to fit conveniently into the habitat and not interfere with other components or operations. To test this concept, a plant growing "atrium" was designed to surround the lift between the lower and upper modules of the Deep Space Habitat and deployed at NASA DRA TS test site in 2011 and at NASA's JSC in 20I2. With this approach, un-utilized volume provided an area for vegetable growth. For the 20 II test, mizuna, lettuce, basil, radish and sweetpotato plants were grown in trays using commercially available red I blue LED light fixtures. Seedlings were transplanted into the atrium and cared for by the crew. Plants were then harvested two weeks later following completion of the test. In 20I2, mizuna, lettuce, and radish plants were grown similarly but under flat panel banks of white LEDs. In 20 I2, the crew went through plant harvesting, including sanitizing the leafy greens and radishes, which were then consumed. Each test demonstrated successful production of vegetables within a functional hab module. The round red I blue LEDs for the 20Il test lighting cast a purple light in the hab, and were less uniformly distributed over the plant trays. The white LED panels provided broad spectrum light with more uniform distribution. Post-test questionnaires showed that the crew enjoyed tending and consuming the plants, and that the white LED light in 2012 provided welcome extra light for the main hab area.

  7. Manipulations to the Alcohol and Sodium Content of Beer for Postexercise Rehydration.

    PubMed

    Desbrow, Ben; Cecchin, Danielle; Jones, Ashleigh; Grant, Gary; Irwin, Chris; Leveritt, Michael

    2015-06-01

    The addition of 25 mmol·L(-1) sodium to low alcohol (2.3% ABV) beer has been shown to enhance post exercise fluid retention compared with full strength (4.8% ABV) beer with and without electrolyte modification. This investigation explored the effect of further manipulations to the alcohol and sodium content of beer on fluid restoration following exercise. Twelve male volunteers lost 2.03 ± 0.19% body mass (mean ± SD) using cycling-based exercise. Participants were then randomly allocated a different beer to consume on four separate occasions. Drinks included low alcohol beer with 25 mmol·L-1 of added sodium [LightBeer+25], low alcohol beer with 50 mmol·L(-1) of added sodium [LightBeer+50], midstrength beer (3.5% ABV) [Mid] or midstrength beer with 25 mmol·L(-1) of added sodium [Mid+25]. Total drink volumes in each trial were equivalent to 150% of body mass loss during exercise, consumed over a 1h period. Body mass, urine samples and regulatory hormones were obtained before and 4 hr after beverage consumption. Total urine output was significantly lower in the LightBeer+50 trial (1450 ± 183 ml) compared with the LightBeer+25 (1796 ± 284 ml), Mid+25 (1786 ± 373 ml) and Mid (1986 ± 304 ml) trials (all p < .05). This resulted in significantly higher net body mass following the LightBeer+50 trial (-0.97 ± 0.17 kg) compared with all other beverages (LightBeer+25 (-1.30 ± 0.24 kg), Mid+25 (-1.38 ±0.33 kg) and Mid (-1.58 ±0.29 kg), all p < .05). No significant changes to aldosterone or vasopressin were associated with different drink treatments. The electrolyte concentration of low alcohol beer appears to have more significant impact on post exercise fluid retention than small changes in alcohol content.

  8. Stereotactic radiosurgery for small brain metastases and implications regarding management with systemic therapy alone.

    PubMed

    Trifiletti, Daniel M; Hill, Colin; Cohen-Inbar, Or; Xu, Zhiyuan; Sheehan, Jason P

    2017-09-01

    While stereotactic radiosurgery (SRS) has been shown effective in the management of brain metastases, small brain metastases (≤10 mm) can pose unique challenges. Our aim was to investigate the efficacy of SRS in the treatment of small brain metastases, as well as elucidate clinically relevant factors impacting local failure (LF). We utilized a large, single-institution cohort to perform a retrospective analysis of patients with brain metastases up to 1 cm in maximal dimension. Clinical and radiosurgical parameters were investigated for an association with LF and compared using a competing risk model to calculate cumulative incidence functions, with death and whole brain radiotherapy serving as competing risks. 1596 small brain metastases treated with SRS among 424 patients were included. Among these tumors, 33 developed LF during the follow-up period (2.4% at 12 months following SRS). Competing risk analysis demonstrated that LF was dependent on tumor size (0.7% if ≤2 mm and 3.0% if 2-10 mm at 12 months, p = 0.016). Other factors associated with increasing risk of LF were the decreasing margin dose, increasing maximal tumor diameter, volume, and radioresistant tumors (each p < 0.01). 22 tumors (0.78%) developed radiographic radiation necrosis following SRS, and this incidence did not differ by tumor size (≤2 mm and 2-10 mm, p = 0.200). This large analysis confirms that SRS remains an effective modality in treatment of small brain metastases. In light of the excellent local control and relatively low risk of toxicity, patients with small brain metastases who otherwise have a reasonable expected survival should be considered for radiosurgical management.

  9. Detector to detector corrections: a comprehensive experimental study of detector specific correction factors for beam output measurements for small radiotherapy beams.

    PubMed

    Azangwe, Godfrey; Grochowska, Paulina; Georg, Dietmar; Izewska, Joanna; Hopfgartner, Johannes; Lechner, Wolfgang; Andersen, Claus E; Beierholm, Anders R; Helt-Hansen, Jakob; Mizuno, Hideyuki; Fukumura, Akifumi; Yajima, Kaori; Gouldstone, Clare; Sharpe, Peter; Meghzifene, Ahmed; Palmans, Hugo

    2014-07-01

    The aim of the present study is to provide a comprehensive set of detector specific correction factors for beam output measurements for small beams, for a wide range of real time and passive detectors. The detector specific correction factors determined in this study may be potentially useful as a reference data set for small beam dosimetry measurements. Dose response of passive and real time detectors was investigated for small field sizes shaped with a micromultileaf collimator ranging from 0.6 × 0.6 cm(2) to 4.2 × 4.2 cm(2) and the measurements were extended to larger fields of up to 10 × 10 cm(2). Measurements were performed at 5 cm depth, in a 6 MV photon beam. Detectors used included alanine, thermoluminescent dosimeters (TLDs), stereotactic diode, electron diode, photon diode, radiophotoluminescent dosimeters (RPLDs), radioluminescence detector based on carbon-doped aluminium oxide (Al2O3:C), organic plastic scintillators, diamond detectors, liquid filled ion chamber, and a range of small volume air filled ionization chambers (volumes ranging from 0.002 cm(3) to 0.3 cm(3)). All detector measurements were corrected for volume averaging effect and compared with dose ratios determined from alanine to derive a detector correction factors that account for beam perturbation related to nonwater equivalence of the detector materials. For the detectors used in this study, volume averaging corrections ranged from unity for the smallest detectors such as the diodes, 1.148 for the 0.14 cm(3) air filled ionization chamber and were as high as 1.924 for the 0.3 cm(3) ionization chamber. After applying volume averaging corrections, the detector readings were consistent among themselves and with alanine measurements for several small detectors but they differed for larger detectors, in particular for some small ionization chambers with volumes larger than 0.1 cm(3). The results demonstrate how important it is for the appropriate corrections to be applied to give consistent and accurate measurements for a range of detectors in small beam geometry. The results further demonstrate that depending on the choice of detectors, there is a potential for large errors when effects such as volume averaging, perturbation and differences in material properties of detectors are not taken into account. As the commissioning of small fields for clinical treatment has to rely on accurate dose measurements, the authors recommend the use of detectors that require relatively little correction, such as unshielded diodes, diamond detectors or microchambers, and solid state detectors such as alanine, TLD, Al2O3:C, or scintillators.

  10. Evaluation of transurethral and transperineal tin ethyl etiopurpurin-photodynamic therapy on the canine prostate one week after drug injection

    NASA Astrophysics Data System (ADS)

    Selman, Steven H.; Keck, Rick W.; Kondo, Sandy; Albrecht, Detlef

    1999-06-01

    We have been investigating the potential applicability of photodynamic therapy for the treatment of benign and malignant disease of the prostate. Both transurethral and transperineal approaches to the delivery of light to the tin ethyl etiopurpurin sensitized canine prostate have been studied. Pharmacologic studies were performed and suggested that delaying light treatment for 7 days after drug administration would maximize the desired effect on the targeted prostatic tissue while minimizing the damage to surrounding bladder and rectum. A total of 12 dogs were treated with transurethral light alone (n=6) or the combination of transurethral light and transperineal light one week after tin ethyl etiopurpurin administration. (Previous studies have shown that light alone has no effect on prostate size or histology.) Animals were euthanized 48 hours and 3 weeks after completion of treatment (drug, 1mg/kg day 0, light [400mw/750sec]day 7). Tissue response was determined by gross and microscopic examination. Additionally, pre- and post- treatment transrectal ultrasounds were compared to assess changes in prostate volume and tissue echogenicity. The combination of transurethral and transperineal light results in extensive destruction of glandular epithelium with minimal damage to surrounding structures. Prostate volumes decreased by an average of 52%. Untreated areas were found to lie greater than 0.5 cm from the light diffuser. These studies have encouraged us to continue to investigate this modality as a technique for total ablation of prostatic glandular epithelium.

  11. Modified Technique For Chemisorption Measurements

    NASA Technical Reports Server (NTRS)

    Schryer, David R.; Brown, Kenneth G.; Schryer, Jacqueline

    1989-01-01

    In measurements of chemisorption of CO on Pt/SnO2 catalyst observed that if small numbers of relatively large volumes of adsorbate gas are passed through sample, very little removal of CO detected. In these cases little or no CO has been chemisorbed on Pt/SnO2. Technique of using large number of small volumes of adsorbate gas to measure chemisorption applicable to many gas/material combinations other than CO on Pt/SnO2. Volume used chosen so that at least 10 percent of adsorbate gas removed during each exposure.

  12. Improving the effectiveness of nighttime temporary traffic control warning devices, volume 2 : evaluation of nighttime mobile warning lights.

    DOT National Transportation Integrated Search

    2013-11-01

    Vehicle-mounted warning lights for nighttime mobile highway operations provide critical protection to workers and the driving : public. Alerting the traveling public of the approaching work activity and providing guidance is vital to maintaining safe...

  13. A new perspective on the raindrop size distribution and its implications for retrievals of light rainfall

    NASA Astrophysics Data System (ADS)

    Gatlin, P. N.; Thurai, M.; Petersen, W. A.; Bringi, V. N.

    2017-12-01

    As GPM facilitates precipitation estimation at higher latitudes where light rainfall is more common it becomes more important that we can fully describe the raindrop size distribution (RSD) across the continuum of observed raindrop sizes. An adequate understanding and the capability to represent the RSD in light rain and drizzle extends from GPM radar algorithms into radiometer-based algorithms, where auto-conversion from cloud to rainwater contents and size distributions becomes important for light rain/drizzle estimation. This study provides insights into the effect of small raindrops on our ability to accurately map rainfall. The RSD has been widely defined using a gamma distribution—the assumption often being verified and approach being reinforced using measurements that imperfectly measure the small end of the RSD. However, we find that the gamma model as it is applied in its current form, to include commonly used disdrometer measurements to define it, is not capable of accurately describing the small raindrops we have observed during light rainfall. We demonstrate the difficulty encountered at light rain rates (e.g., 0.5 mm/hr or less) and for drops typically < 0.6 - 0.7 mm in diameter using a disdrometer with a pixel resolution of 50 microns operated alongside a 2DVD, with both instruments inside a small DFIR wind fence. Measurements were made in two locations with different climates—Greely, Colorado and Huntsville, Alabama. The resultant comparison reveals that the gamma RSD model overestimates the characteristic raindrop diameter (Dm), especially for light rainfall. A generalized gamma distribution provides a closer fit to the RSD observations across the continuum of raindrop sizes and highlights a drizzle mode of the RSD exists that would otherwise not be described with the commonly used gamma RSD model. Our analysis also suggests that RSD-based separation of stratiform and convective rainfall requires special consideration for light rainfall cases, especially those with small mass-weighted mean diameters (Dm < 0.6 mm).

  14. Stochastic theory of large-scale enzyme-reaction networks: Finite copy number corrections to rate equation models

    NASA Astrophysics Data System (ADS)

    Thomas, Philipp; Straube, Arthur V.; Grima, Ramon

    2010-11-01

    Chemical reactions inside cells occur in compartment volumes in the range of atto- to femtoliters. Physiological concentrations realized in such small volumes imply low copy numbers of interacting molecules with the consequence of considerable fluctuations in the concentrations. In contrast, rate equation models are based on the implicit assumption of infinitely large numbers of interacting molecules, or equivalently, that reactions occur in infinite volumes at constant macroscopic concentrations. In this article we compute the finite-volume corrections (or equivalently the finite copy number corrections) to the solutions of the rate equations for chemical reaction networks composed of arbitrarily large numbers of enzyme-catalyzed reactions which are confined inside a small subcellular compartment. This is achieved by applying a mesoscopic version of the quasisteady-state assumption to the exact Fokker-Planck equation associated with the Poisson representation of the chemical master equation. The procedure yields impressively simple and compact expressions for the finite-volume corrections. We prove that the predictions of the rate equations will always underestimate the actual steady-state substrate concentrations for an enzyme-reaction network confined in a small volume. In particular we show that the finite-volume corrections increase with decreasing subcellular volume, decreasing Michaelis-Menten constants, and increasing enzyme saturation. The magnitude of the corrections depends sensitively on the topology of the network. The predictions of the theory are shown to be in excellent agreement with stochastic simulations for two types of networks typically associated with protein methylation and metabolism.

  15. Age and character of basaltic rocks of the Yucca Mountain region, southern Nevada

    USGS Publications Warehouse

    Fleck, R.J.; Turrin, B.D.; Sawyer, D.A.; Warren, R.G.; Champion, D.E.; Hudson, M.R.; Minor, S.A.

    1996-01-01

    Volcanism in the Yucca Mountain region of southern Nevada in the last 5 m.y. is restricted to moderate-to-small volumes of subalkaline basaltic magmas, produced during at least 6 intervals, and spanning an age range from 4.6 Ma to about 125 ka. Where paleomagnetic evidence is available, the period of volcanism at individual eruptive centers apparently was geologically short-lived, even where multiple eruptions involved different magma types. K-Ar studies are consistent with most other geochronologic information, such as the minimum ages of exposure-dating techniques, and show no evidence of renewed volcanism after a significant quiescence at any of the centers in the Yucca Mountain region. A volcanic recurrence interval of 860 ?? 350 kyr is computed from a large K-Ar data set and an evaluation of their uncertainties. Monte Carlo error propagations demonstrate the validity of uncertainties obtained for weighted-mean ages when modified using the goodness of fit parameter, MSWD. Elevated 87Sr/86Sr initial ratios (Sri) in the basalts, nearly constant at 0.707, combined with low SiO2 and Rb/Sr ratios indicate a subcontinental, lithospheric mantle source, previously enriched in radiogenic Sr and depleted in Rb. Beginning with eruptions of the most voluminous eruptive center, the newly dated Pliocene Thirsty Mountain volcano, basaltic magmas have decreased in eruptive volume, plagioclase-phenocryst content, various trace element ratios, and TiO2, while increasing in light rare earth elements, U, Th, P2O5, and light REE/heavy REE ratios. These time-correlated changes are consistent with either increasing depths of melting or a decreasing thermal gradient in the Yucca Mountain region during the last 5 m.y.

  16. A reflectance model for non-contact mapping of venous oxygen saturation using a CCD camera

    NASA Astrophysics Data System (ADS)

    Li, Jun; Dunmire, Barbrina; Beach, Kirk W.; Leotta, Daniel F.

    2013-11-01

    A method of non-contact mapping of venous oxygen saturation (SvO2) is presented. A CCD camera is used to image skin tissue illuminated alternately by a red (660 nm) and an infrared (800 nm) LED light source. Low cuff pressures of 30-40 mmHg are applied to induce a venous blood volume change with negligible change in the arterial blood volume. A hybrid model combining the Beer-Lambert law and the light diffusion model is developed and used to convert the change in the light intensity to the change in skin tissue absorption coefficient. A simulation study incorporating the full light diffusion model is used to verify the hybrid model and to correct a calculation bias. SvO2 in the fingers, palm, and forearm for five volunteers are presented and compared with results in the published literature. Two-dimensional maps of venous oxygen saturation are given for the three anatomical regions.

  17. 47 CFR 80.925 - Electric light.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Electric light. 80.925 Section 80.925... MARITIME SERVICES Compulsory Radiotelephone Installations for Small Passenger Boats § 80.925 Electric light. (a) If the vessel is navigated at night an electric light or dial lights which clearly illuminate the...

  18. 47 CFR 80.925 - Electric light.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 5 2014-10-01 2014-10-01 false Electric light. 80.925 Section 80.925... MARITIME SERVICES Compulsory Radiotelephone Installations for Small Passenger Boats § 80.925 Electric light. (a) If the vessel is navigated at night an electric light or dial lights which clearly illuminate the...

  19. 47 CFR 80.925 - Electric light.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 5 2012-10-01 2012-10-01 false Electric light. 80.925 Section 80.925... MARITIME SERVICES Compulsory Radiotelephone Installations for Small Passenger Boats § 80.925 Electric light. (a) If the vessel is navigated at night an electric light or dial lights which clearly illuminate the...

  20. 47 CFR 80.925 - Electric light.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 5 2011-10-01 2011-10-01 false Electric light. 80.925 Section 80.925... MARITIME SERVICES Compulsory Radiotelephone Installations for Small Passenger Boats § 80.925 Electric light. (a) If the vessel is navigated at night an electric light or dial lights which clearly illuminate the...

  1. 47 CFR 80.925 - Electric light.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 5 2013-10-01 2013-10-01 false Electric light. 80.925 Section 80.925... MARITIME SERVICES Compulsory Radiotelephone Installations for Small Passenger Boats § 80.925 Electric light. (a) If the vessel is navigated at night an electric light or dial lights which clearly illuminate the...

  2. Construction of a cost effective optical tweezers for manipulation of birefringent materials using circularly polarized light

    NASA Astrophysics Data System (ADS)

    McMahon, Allison; Sauncy, Toni

    2008-10-01

    Light manipulation is a very powerful tool in physics, biology, and chemistry. There are several physical principles underlying the apparatus known as the ``optical tweezers,'' the term given to using focused light to manipulate and control small objects. By carefully controlling the orientation and position of a focused laser beam, dielectric particles can be effectively trapped and manipulated. We have designed a cost efficient and effective undergraduate optical tweezers apparatus by using standard ``off the shelf'' components and starting with a standard undergraduate laboratory microscope. Images are recorded using a small CCD camera interfaced to a computer and controlled by LabVIEW^TM software. By using wave plates to produce circular polarized light, rotational motion can be induced in small particles of birefringent materials such as calcite and mica.

  3. Effects of light on direct and indirect defences against herbivores of young plants of Mallotus japonicus demonstrate a trade-off between two indirect defence traits

    PubMed Central

    Yamawo, Akira; Hada, Yoshio

    2010-01-01

    Background and Aims Although most studies on plant defence strategies have focused on a particular defence trait, some plant species develop multiple defence traits. To clarify the effects of light on the development of multiple defence traits, the production of direct and indirect defence traits of young plants of Mallotus japonicus were examined experimentally under different light conditions. Methods The young plants were cultivated under three light conditions in the experimental field for 3 months from May to July. Numbers of ants and pearl bodies on leaves in July were examined. After cultivation, the plants were collected and the developments of trichomes and pellucid dots, and extrafloral nectaries (EFNs) on the leaves were examined. On plants without nectar-collecting insects, the size of EFNs and the volume of extrafloral nectar secreted from the EFNs were examined. Key results Densities of trichomes and pellucid dots did not differ significantly among the plants under the different light conditions, suggesting that the chemical and physical defences function under both high and low light availability. The number of EFNs on the leaves did not differ significantly among the plants under the different light conditions, but there appeared to be a trade-off between the size of EFNs and the number of pearl bodies; the largest EFNs and the smallest number of pearl bodies were found under high light availability. EFN size was significantly correlated with the volume of extrafloral nectar secreted for 24 h. The number of ants on the plants was smaller under low light availability than under high and moderate light availability. Conclusions These results suggest that direct defence traits function regardless of light conditions, but light conditions affected the development of indirect defence traits. PMID:20472698

  4. Availability and temporal heterogeneity of water supply affect the vertical distribution and mortality of a belowground herbivore and consequently plant growth.

    PubMed

    Tsunoda, Tomonori; Kachi, Naoki; Suzuki, Jun-Ichirou

    2014-01-01

    We examined how the volume and temporal heterogeneity of water supply changed the vertical distribution and mortality of a belowground herbivore, and consequently affected plant biomass. Plantago lanceolata (Plantaginaceae) seedlings were grown at one per pot under different combinations of water volume (large or small volume) and heterogeneity (homogeneous water conditions, watered every day; heterogeneous conditions, watered every 4 days) in the presence or absence of a larva of the belowground herbivorous insect, Anomala cuprea (Coleoptera: Scarabaeidae). The larva was confined in different vertical distributions to top feeding zone (top treatment), middle feeding zone (middle treatment), or bottom feeding zone (bottom treatment); alternatively no larva was introduced (control treatment) or larval movement was not confined (free treatment). Three-way interaction between water volume, heterogeneity, and the herbivore significantly affected plant biomass. With a large water volume, plant biomass was lower in free treatment than in control treatment regardless of heterogeneity. Plant biomass in free treatment was as low as in top treatment. With a small water volume and in free treatment, plant biomass was low (similar to that under top treatment) under homogeneous water conditions but high under heterogeneous ones (similar to that under middle or bottom treatment). Therefore, there was little effect of belowground herbivory on plant growth under heterogeneous water conditions. In other watering regimes, herbivores would be distributed in the shallow soil and reduced root biomass. Herbivore mortality was high with homogeneous application of a large volume or heterogeneous application of a small water volume. Under the large water volume, plant biomass was high in pots in which the herbivore had died. Thus, the combinations of water volume and heterogeneity affected plant growth via the change of a belowground herbivore.

  5. Sheet-scanned dual-axis confocal microscopy using Richardson-Lucy deconvolution.

    PubMed

    Wang, D; Meza, D; Wang, Y; Gao, L; Liu, J T C

    2014-09-15

    We have previously developed a line-scanned dual-axis confocal (LS-DAC) microscope with subcellular resolution suitable for high-frame-rate diagnostic imaging at shallow depths. Due to the loss of confocality along one dimension, the contrast (signal-to-background ratio) of a LS-DAC microscope is deteriorated compared to a point-scanned DAC microscope. However, by using a sCMOS camera for detection, a short oblique light-sheet is imaged at each scanned position. Therefore, by scanning the light sheet in only one dimension, a thin 3D volume is imaged. Both sequential two-dimensional deconvolution and three-dimensional deconvolution are performed on the thin image volume to improve the resolution and contrast of one en face confocal image section at the center of the volume, a technique we call sheet-scanned dual-axis confocal (SS-DAC) microscopy.

  6. The Importance of the Effective Utilization of Women at Arms

    DTIC Science & Technology

    2015-03-01

    Network Presented in Zagreb ,” South Eastern and Eastern Europe Clearinghouse for the Control of Small Arms and Light Weapons, November 5, 2010, http...for the Control of Small Arms and Light Weapons. “Report Establishing the South East Europe Women Police Officers Network Presented in Zagreb

  7. A Screening Model to Predict Microalgae Biomass Growth in Photobioreactors and Raceway Ponds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huesemann, Michael H.; Van Wagenen, Jonathan M.; Miller, Tyler W.

    A microalgae biomass growth model was developed for screening novel strains for their potential to exhibit high biomass productivities under nutrient-replete conditions in photobioreactors or outdoor ponds. Growth is modeled by first estimating the light attenuation by biomass according to Beer-Lambert’s law, and then calculating the specific growth rate in discretized culture volume slices that receive declining light intensities due to attenuation. The model requires only two physical and two species-specific biological input parameters, all of which are relatively easy to determine: incident light intensity, culture depth, as well as the biomass light absorption coefficient and the specific growth ratemore » as a function of light intensity. Roux bottle culture experiments were performed with Nannochloropsis salina at constant temperature (23 °C) at six different incident light intensities (5, 10, 25, 50, 100, 250, and 850 μmol/m2∙ sec) to determine both the specific growth rate under non-shading conditions and the biomass light absorption coefficient as a function of light intensity. The model was successful in predicting the biomass growth rate in these Roux bottle cultures during the light-limited linear phase at different incident light intensities. Model predictions were moderately sensitive to minor variations in the values of input parameters. The model was also successful in predicting the growth performance of Chlorella sp. cultured in LED-lighted 800 L raceway ponds operated at constant temperature (30 °C) and constant light intensity (1650 μmol/m2∙ sec). Measurements of oxygen concentrations as a function of time demonstrated that following exposure to darkness, it takes at least 5 seconds for cells to initiate dark respiration. As a result, biomass loss due to dark respiration in the aphotic zone of a culture is unlikely to occur in highly mixed small-scale photobioreactors where cells move rapidly in and out of the light. By contrast, as supported also by the growth model, biomass loss due to dark respiration occurs in the dark zones of the relatively less well mixed pond cultures. In addition to screening novel microalgae strains for high biomass productivities, the model can also be used for optimizing the pond design and operation. Additional research is needed to validate the biomass growth model for other microalgae species and for the more realistic case of fluctuating temperatures and light intensities observed in outdoor pond cultures.« less

  8. A screening model to predict microalgae biomass growth in photobioreactors and raceway ponds.

    PubMed

    Huesemann, M H; Van Wagenen, J; Miller, T; Chavis, A; Hobbs, S; Crowe, B

    2013-06-01

    A microalgae biomass growth model was developed for screening novel strains for their potential to exhibit high biomass productivities under nutrient-replete conditions in photobioreactors or outdoor ponds. Growth is modeled by first estimating the light attenuation by biomass according to Beer-Lambert's Law, and then calculating the specific growth rate in discretized culture volume slices that receive declining light intensities due to attenuation. The model uses only two physical and two species-specific biological input parameters, all of which are relatively easy to determine: incident light intensity, culture depth, as well as the biomass light absorption coefficient and the specific growth rate as a function of light intensity. Roux bottle culture experiments were performed with Nannochloropsis salina at constant temperature (23°C) at six different incident light intensities (10, 25, 50, 100, 250, and 850 µmol/m(2)  s) to determine both the specific growth rate under non-shading conditions and the biomass light absorption coefficient as a function of light intensity. The model was successful in predicting the biomass growth rate in these Roux bottle batch cultures during the light-limited linear phase at different incident light intensities. Model predictions were moderately sensitive to minor variations in the values of input parameters. The model was also successful in predicting the growth performance of Chlorella sp. cultured in LED-lighted 800 L raceway ponds operated in batch mode at constant temperature (30°C) and constant light intensity (1,650 µmol/m(2)  s). Measurements of oxygen concentrations as a function of time demonstrated that following exposure to darkness, it takes at least 5 s for cells to initiate dark respiration. As a result, biomass loss due to dark respiration in the aphotic zone of a culture is unlikely to occur in highly mixed small-scale photobioreactors where cells move rapidly in and out of the light. By contrast, as supported also by the growth model, biomass loss due to dark respiration occurs in the dark zones of the relatively less well-mixed pond cultures. In addition to screening novel microalgae strains for high biomass productivities, the model can also be used for optimizing the pond design and operation. Additional research is needed to validate the biomass growth model for other microalgae species and for the more realistic case of fluctuating temperatures and light intensities observed in outdoor pond cultures. Copyright © 2012 Wiley Periodicals, Inc.

  9. Influence of thermal expansion on shrinkage during photopolymerization of dental resins based on bis-GMA/TEGDMA.

    PubMed

    Mucci, Veronica; Arenas, Gustavo; Duchowicz, Ricardo; Cook, Wayne D; Vallo, Claudia

    2009-01-01

    The aim of this study was to assess volume changes that occur during photopolymerization of unfilled dental resins based on bis-GMA-TEGDMA. The resins were activated for visible light polymerization by the addition of camphorquinone (CQ) in combination with dimethylamino ethylmethacrylate (DMAEMA) or ethyl-4-dimethyl aminobenzoate (EDMAB). A fibre-optic sensing method based on a Fizeau-type interferometric scheme was employed for monitoring contraction during photopolymerization. Measurements were carried out on 10mm diameter specimens of different thicknesses (1 and 2mm). The high exothermic nature of the polymerization resulted in volume expansion during the heating, and this effect was more pronounced when the sample thickness increased. Two approaches to assess volume changes due to thermal effects are presented. Due to the difference in thermal expansion coefficients between the rubbery and glassy resins, the increase of volume due to thermal expansion was greater than the decrease in volume due to thermal contraction. As a result, the volume of the vitrified resins was greater than that calculated from polymerization contraction. The observed trends of shrinkage versus sample thickness are explained in terms of light attenuation across the path length during photopolymerization. Results obtained in this research highlight the inherent interlinking of non-isothermal photopolymerization and volumetric changes in bulk polymerizing systems.

  10. Measurement of the airway surface liquid volume with simple light refraction microscopy.

    PubMed

    Harvey, Peter R; Tarran, Robert; Garoff, Stephen; Myerburg, Mike M

    2011-09-01

    In the cystic fibrosis (CF) lung, the airway surface liquid (ASL) volume is depleted, impairing mucus clearance from the lung and leading to chronic airway infection and obstruction. Several therapeutics have been developed that aim to restore normal airway surface hydration to the CF airway, yet preclinical evaluation of these agents is hindered by the paucity of methods available to directly measure the ASL. Therefore, we sought to develop a straightforward approach to measure the ASL volume that would serve as the basis for a standardized method to assess mucosal hydration using readily available resources. Primary human bronchial epithelial (HBE) cells cultured at an air-liquid interface develop a liquid meniscus at the edge of the culture. We hypothesized that the size of the fluid meniscus is determined by the ASL volume, and could be measured as an index of the epithelial surface hydration status. A simple method was developed to measure the volume of fluid present in meniscus by imaging the refraction of light at the ASL interface with the culture wall using low-magnification microscopy. Using this method, we found that primary CF HBE cells had a reduced ASL volume compared with non-CF HBE cells, and that known modulators of ASL volume caused the predicted responses. Thus, we have demonstrated that this method can detect physiologically relevant changes in the ASL volume, and propose that this novel approach may be used to rapidly assess the effects of airway hydration therapies in high-throughput screening assays.

  11. Photoacoustic thermal flowmetry with a single light source

    NASA Astrophysics Data System (ADS)

    Liu, Wei; Lan, Bangxin; Hu, Leo; Chen, Ruimin; Zhou, Qifa; Yao, Junjie

    2017-09-01

    We report a photoacoustic thermal flowmetry based on optical-resolution photoacoustic microscopy (OR-PAM) using a single laser source for both thermal tagging and photoacoustic excitation. When an optically absorbing medium is flowing across the optical focal zone of OR-PAM, a small volume of the medium within the optical focus is repeatedly illuminated and heated by a train of laser pulses with a high repetition rate. The average temperature of the heated volume at each laser pulse is indicated by the photoacoustic signal excited by the same laser pulse due to the well-established linear relationship between the Grueneisen coefficient and the local temperature. The thermal dynamics of the heated medium volume, which are closely related to the flow speed, can therefore be measured from the time course of the detected photoacoustic signals. Here, we have developed a lumped mathematical model to describe the time course of the photoacoustic signals as a function of the medium's flow speed. We conclude that the rising time constant of the photoacoustic signals is linearly dependent on the flow speed. Thus, the flow speed can be quantified by fitting the measured photoacoustic signals using the derived mathematical model. We first performed proof-of-concept experiments using defibrinated bovine blood flowing in a plastic tube. The experiment results have demonstrated that the proposed method has high accuracy (˜±6%) and a wide range of measurable flow speeds. We further validated the method by measuring the blood flow speeds of the microvasculature in a mouse ear in vivo.

  12. Mass-action model analysis of the apparent molar volume and heat capacity of pluronics in water and liposome suspensions at 25 °C.

    PubMed

    Quirion, François; Meilleur, Luc; Lévesque, Isabelle

    2013-07-09

    Pluronics are block copolymers composed of a central block of polypropylene oxide and two side chains of polyethylene oxide. They are used in water to generate aggregates and gels or added to phospholipid suspensions to prepare microparticles for drug delivery applications. The structure of these systems has been widely investigated. However, little is known about the mechanisms leading to these structures. This investigation compares the apparent molar volumes and heat capacities of Pluronics F38, F108, F127, P85, P104, and P103 at 25 °C in water and in the presence of lecithin liposomes. The changes in molar volumes, heat capacities, and enthalpies generated by a mass-action model are in good agreement with the loss of hydrophobic hydration of the polypropylene oxide central block of the Pluronics. However, the molecularity of the endothermic transitions is much smaller than the aggregation numbers reported in the literature for the same systems. It is suggested that Pluronics go through dehydration of their central block to form unimolecular or small entities having a hydrophobic polypropylene oxide core. In water, these entities would assemble athermally to form larger aggregates. In the presence of liposomes, they would be transferred into the hydrophobic lecithin bilayers of the liposomes. Light transmission experiments suggest that the liposome suspensions are significantly altered only when the added Pluronics are in the dehydrated state.

  13. New fluorescence correlation spectroscopy enabling direct observation of spatiotemporal dependence of diffusion constants as an evidence of anomalous transport in extracellular matrices.

    PubMed

    Masuda, Akiko; Ushida, Kiminori; Okamoto, Takayuki

    2005-05-01

    The potential of fluorescence correlation spectroscopy (FCS) is extended to enable the direct observation of anomalous subdiffusion (ASD) in inhomogeneous media that are of great importance particularly in many biological systems, such as membranes, cytoplasm, and extracellular matrices (ECMs). Because ASD can be confirmed by monitoring the spatiotemporal dependence of observable diffusion coefficients (D(obs)), the size of the effective confocal volume (V(eff)) for FCS sampling (sampling volume) was continuously changed on a scale of 300-500 nm using a motorized variable beam expander through which an illuminating laser beam passes. This new method, namely, sampling-volume-controlled (SVC)-FCS, was applied to the analysis of hyaluronan (HA) aqueous solutions where the D(obs) of light-emitting solute (Alexa 488) markedly changed, corresponding to the change in V(eff) (220-340 nm in the half-axis), because the network structure of HA of 7-33 nm (nanostructure) interferes with the material transport within it. The results indicate that moderate ASD may occur even in the presence of a small amount ( approximately 0.1 wt %) of HA in ECM. Because the change in D(obs) along with the traveling distance (the mean-square displacement) can be identified even in systems with no deformation of the autocorrelation function, this technique has a great potential for general applications to many biological systems in which ASD shows complex time and space dependences.

  14. The impact of the concentration of casein micelles and whey protein-stabilized fat globules on the rennet-induced gelation of milk.

    PubMed

    Gaygadzhiev, Zafir; Corredig, Milena; Alexander, Marcela

    2009-02-01

    The rennet-induced aggregation of skim milk recombined with whey protein-stabilized emulsion droplets was studied using diffusing wave spectroscopy (DSW) and small deformation rheology. The effect of different volume fractions of casein micelles and fat globules was investigated by observing changes in turbidity (1/l*), apparent radius, elastic modulus and mean square displacement (MSD), in addition to confocal imaging of the gels. Skim milk containing different concentration of casein micelles showed comparable light-scattering profiles; a higher volume fraction of caseins led to the development of more elastic gels. By following the development of 1/l* in recombined milks, it was possible to describe the behaviour of the fat globules during the initial stages of rennet coagulation. Increasing the volume fraction of fat globules showed a significant increase in gel elasticity, caused by flocculation of the oil droplets. The presence of flocculated oil globules within the gel structure was confirmed by confocal microscopy observations. Moreover, a lower degree of kappa-casein hydrolysis was needed to initiate casein micelles aggregation in milk containing whey protein-stabilized oil droplets compared to skim milk. This study for the first time clearly describes the impact of a mixture of casein micelles and whey protein-stabilized fat globules on the pre-gelation stages of rennet coagulation, and further highlights the importance of the flocculation state of the emulsion droplets in affecting the structure formation of the gel.

  15. Strategies for Small Volume Resuscitation: Hyperosmotic-Hyperoncotic Solutions, Hemoglobin Based Oxygen Carriers and Closed-Loop Resuscitation

    NASA Technical Reports Server (NTRS)

    Kramer, George C.; Wade, Charles E.; Dubick, Michael A.; Atkins, James L.

    2004-01-01

    Introduction: Logistic constraints on combat casualty care preclude traditional resuscitation strategies which can require volumes and weights 3 fold or greater than hemorrhaged volume. We present a review of quantitative analyses of clinical and animal data on small volume strategies using 1) hypertonic-hyperosmotic solutions (HHS); 2) hemoglobin based oxygen carriers (HBOCs) and 3) closed-loop infusion regimens.Methods and Results: Literature searches and recent queries to industry and academic researchers have allowed us to evaluate the record of 81 human HHS studies (12 trauma trials), 19 human HBOCs studies (3trauma trials) and two clinical studies of closed-loop resuscitation.There are several hundreds animal studies and at least 82 clinical trials and reports evaluating small volume7.2%-7.5% hypertonic saline (HS) most often combined with colloids, e.g., dextran (HSD) or hetastarch(HSS). HSD and HSS data has been published for 1,108 and 392 patients, respectively. Human studies have documented volume sparing and hemodynamic improvements. Meta-analyses suggest improved survival for hypotensive trauma patients treated with HSD with significant reductions in mortality found for patients with blood pressure < 70 mmHg, head trauma, and penetrating injury requiring surgery. HSD and HSS have received regulatory approval in 14 and 3 countries, respectively, with 81,000+ units sold. The primary reported use was head injury and trauma resuscitation. Complications and reported adverse events are surprisingly rare and not significantly different from other solutions.HBOCs are potent volume expanders in addition to oxygen carriers with volume expansion greater than standard colloids. Several investigators have evaluated small volume hyperoncotic HBOCs or HS-HBOC formulations for hypotensive and normotensive resuscitation in animals. A consistent finding in resuscitation with HBOCs is depressed cardiac output. There is some evidence that HBOCs more efficiently unload oxygen from plasma hemoglobin as well as facilitate RBC unloading. We analyzed one volunteer study, 15 intraoperative trials, and 3 trauma studies using HBOCs. Perioperative studies generally suggest ability to deliver oxygen, but one trauma trial using HBOCs (HemAssist) for treatment of trauma resulted in a dramatic increase in mortality, while an intraoperative trauma study using Polyheme demonstrated reductions in blood use and lower mortality compared to historic controls of patients refusing blood. Transfusion reductions with HBOC use have been modest. Two HBOCs (Hemopure and Polyheme) are now in new or planned large-scale multicenter prehospital trials of trauma treatment. A new implementation of small volume resuscitation is closed-loop resuscitation (CLR), which employs microprocessors to titrate just enough fluid to reach a physiologic target . Animal studies suggest less risk of rebleeding in uncontrolled hemorrhage and a reduction in fluid needs with CLR. The first clinical application of CLR was treatment of burn shock and the US Army. Conclusions: Independently sponsored civilian trauma trials and clinical evaluations in operational combat conditions of different small volume strategies are warranted.

  16. Small Business Management. Addendum to Small Business Management Education Curriculum Volume III.

    ERIC Educational Resources Information Center

    Minnesota Univ., St. Paul. Dept. of Agricultural Education.

    A supplement to a previous volume (CE 009 649), this document contains handouts, case problems, schedules, and seminar information keyed to specific units of instruction. The contents by year and unit areas are as follow: year I, unit 1--time management (two-page handout concerning four problems to avoid; year I, unit 2--warranty register (a…

  17. A Simple Theory to Predict Small Changes in Volume and Refractivity During Mixing of a Two-Component Liquid System.

    ERIC Educational Resources Information Center

    Aminabhavi, Tejraj M.

    1983-01-01

    Discusses a set of relations (addressing changes in volume and refractivity) for use in the study of binary systems. Suggests including such an experiment in undergraduate physical chemistry courses (measuring density/refractive index of pure compounds and their mixtures) to predict even small changes occurring during mixing process. (Author/JN)

  18. High efficiency solar cells for concentrator systems: silicon or multi-junction?

    NASA Astrophysics Data System (ADS)

    Slade, Alexander; Stone, Kenneth W.; Gordon, Robert; Garboushian, Vahan

    2005-08-01

    Amonix has become the first company to begin production of high concentration silicon solar cells where volumes are over 10 MW/year. Higher volumes are available due to the method of manufacture; Amonix solely uses semiconductor foundries for solar cell production. In the previous years of system and cell field testing, this method of manufacturing enabled Amonix to maintain a very low overhead while incurring a high cost for the solar cell. However, recent simplifications to the solar cell processing sequence resulted in cost reduction and increased yield. This new process has been tested by producing small qualities in very short time periods, enabling a simulation of high volume production. Results have included over 90% wafer yield, up to 100% die yield and world record performance (η =27.3%). This reduction in silicon solar cell cost has increased the required efficiency for multi-junction concentrator solar cells to be competitive / advantageous. Concentrator systems are emerging as a low-cost, high volume option for solar-generated electricity due to the very high utilization of the solar cell, leading to a much lower $/Watt cost of a photovoltaic system. Parallel to this is the onset of alternative solar cell technologies, such as the very high efficiency multi-junction solar cells developed at NREL over the last two decades. The relatively high cost of these type of solar cells has relegated their use to non-terrestrial applications. However, recent advancements in both multi-junction concentrator cell efficiency and their stability under high flux densities has made their large-scale terrestrial deployment significantly more viable. This paper presents Amonix's experience and testing results of both high-efficiency silicon rear-junction solar cells and multi-junction solar cells made for concentrated light operation.

  19. Single-molecule optomechanics in "picocavities".

    PubMed

    Benz, Felix; Schmidt, Mikolaj K; Dreismann, Alexander; Chikkaraddy, Rohit; Zhang, Yao; Demetriadou, Angela; Carnegie, Cloudy; Ohadi, Hamid; de Nijs, Bart; Esteban, Ruben; Aizpurua, Javier; Baumberg, Jeremy J

    2016-11-11

    Trapping light with noble metal nanostructures overcomes the diffraction limit and can confine light to volumes typically on the order of 30 cubic nanometers. We found that individual atomic features inside the gap of a plasmonic nanoassembly can localize light to volumes well below 1 cubic nanometer ("picocavities"), enabling optical experiments on the atomic scale. These atomic features are dynamically formed and disassembled by laser irradiation. Although unstable at room temperature, picocavities can be stabilized at cryogenic temperatures, allowing single atomic cavities to be probed for many minutes. Unlike traditional optomechanical resonators, such extreme optical confinement yields a factor of 10 6 enhancement of optomechanical coupling between the picocavity field and vibrations of individual molecular bonds. This work sets the basis for developing nanoscale nonlinear quantum optics on the single-molecule level. Copyright © 2016, American Association for the Advancement of Science.

  20. Detecting single viruses and nanoparticles using whispering gallery microlasers.

    PubMed

    He, Lina; Ozdemir, Sahin Kaya; Zhu, Jiangang; Kim, Woosung; Yang, Lan

    2011-06-26

    There is a strong demand for portable systems that can detect and characterize individual pathogens and other nanoscale objects without the use of labels, for applications in human health, homeland security, environmental monitoring and diagnostics. However, most nanoscale objects of interest have low polarizabilities due to their small size and low refractive index contrast with the surrounding medium. This leads to weak light-matter interactions, and thus makes the label-free detection of single nanoparticles very difficult. Micro- and nano-photonic devices have emerged as highly sensitive platforms for such applications, because the combination of high quality factor Q and small mode volume V leads to significantly enhanced light-matter interactions. For example, whispering gallery mode microresonators have been used to detect and characterize single influenza virions and polystyrene nanoparticles with a radius of 30 nm (ref. 12) by measuring in the transmission spectrum either the resonance shift or mode splitting induced by the nanoscale objects. Increasing Q leads to a narrower resonance linewidth, which makes it possible to resolve smaller changes in the transmission spectrum, and thus leads to improved performance. Here, we report a whispering gallery mode microlaser-based real-time and label-free detection method that can detect individual 15-nm-radius polystyrene nanoparticles, 10-nm gold nanoparticles and influenza A virions in air, and 30 nm polystyrene nanoparticles in water. Our approach relies on measuring changes in the beat note that is produced when an ultra-narrow emission line from a whispering gallery mode microlaser is split into two modes by a nanoscale object, and these two modes then interfere. The ultimate detection limit is set by the laser linewidth, which can be made much narrower than the resonance linewidth of any passive resonator. This means that microlaser sensors have the potential to detect objects that are too small to be detected by passive resonator sensors.

Top