Sample records for small-diameter arterial constructs

  1. Influence of coronary artery diameter on eNOS protein content

    NASA Technical Reports Server (NTRS)

    Laughlin, M. H.; Turk, J. R.; Schrage, W. G.; Woodman, C. R.; Price, E. M.

    2003-01-01

    The purpose of this study was to test the hypothesis that the content of endothelial nitric oxide synthase (eNOS) protein (eNOS protein/g total artery protein) increases with decreasing artery diameter in the coronary arterial tree. Content of eNOS protein was determined in porcine coronary arteries with immunoblot analysis. Arteries were isolated in six size categories from each heart: large arteries [301- to 2,500-microm internal diameter (ID)], small arteries (201- to 300-microm ID), resistance arteries (151- to 200-microm ID), large arterioles (101- to 150-microm ID), intermediate arterioles (51- to 100-microm ID), and small arterioles(<50-microm ID). To obtain sufficient protein for analysis from small- and intermediate-sized arterioles, five to seven arterioles 1-2 mm in length were pooled into one sample for each animal. Results establish that the number of smooth muscle cells per endothelial cell decreases from a number of 10 to 15 in large coronary arteries to 1 in the smallest arterioles. Immunohistochemistry revealed that eNOS is located only in endothelial cells in all sizes of coronary artery and in coronary capillaries. Contrary to our hypothesis, eNOS protein content did not increase with decreasing size of coronary artery. Indeed, the smallest coronary arterioles had less eNOS protein per gram of total protein than the large coronary arteries. These results indicate that eNOS protein content is greater in the endothelial cells of conduit arteries, resistance arteries, and large arterioles than in small coronary arterioles.

  2. Effects of diabetes and hypertension on structure and distensibilty of human small coronary arteries.

    PubMed

    Lynch, Fiona M; Izzard, Ashley S; Austin, Clare; Prendergast, Brian; Keenan, Daniel; Malik, Rayaz A; Heagerty, Anthony M

    2012-02-01

    Previous studies have demonstrated that hypertension and diabetes induce significant structural remodelling of resistance arteries from various vascular beds. The hypothesis of this study is that structural alterations of small coronary arteries may occur during hypertension and diabetes. This study is the first to compare human coronary small resistance artery structure from normotensive and hypertensive patients, with and without diabetes undergoing coronary arterial bypass graft surgery. Small arteries were dissected from the atrial appendage removed from nondiabetic normotensive patients, nondiabetic hypertension and diabetic normotensive patients and hypertensive diabetic patients. Arteries were mounted in a pressure myograph and lumen diameter and wall thickness were measured across the pressure range of 3-100 mmHg to assess vessel structure and distensibility. There were no significant differences in the lumen diameter, wall thickness, wall-to-lumen ratio and cross-sectional area of arteries in all groups. Arteries from nondiabetic patients with hypertension demonstrated decreased distensibility compared with nondiabetic normotensive patients. There is no difference in distensibility between vessels from diabetic hypertensive patients and either diabetic or nondiabetic normotensive patients. Neither diabetes nor hypertension appears to have influenced arterial structure which may indicate that successful treatment of hypertension is associated with normal vascular structure in coronary small arteries.

  3. [Efferent innervation of the arteries of human leptomeninx in arterial hypertension].

    PubMed

    Chertok, V M; Kotsiuba, A E; Babich, E V

    2009-01-01

    Structure of the efferent nerve plexuses (adrenergic, acetylcholinestherase- and cholinacetyltranspherase-positive, NO-dependent), was studied in the arteries of human leptomeninx with different diameters. Material was obtained from the corpses of the healthy people and of the patients with initial stages of arterial hypertension (AH). It was shown that the concentrations of cholinergic and adrenergic nerve fibers and varicosities in axon terminal part, innervating the arteries with the diameters ranging from 450 till 100 microm, were not significantly different. In these arteries, NO-ergic plexuses were also detected. In patients with AH, regardless the arterial diameters, the significant increase (up to 15-20%) of adrenergic nerve fiber and varicosity concentrations was found. The changes in cholinergic nerve fiber concentration were found to depend on the vessel diameter: the significant decrease of these parameter was observed only in arteries with the diameter of 100-200 microm. No significant changes in nerve plexus concentration was noticed in the arteries with greater or smaller diameter. In NO-ergic neural conductors, the enzyme activity decreased only in the large arteries, and remained almost unchanged in the small vascular branches. The changes in the vasomotor innervation described in AH, are interpreted as a vasomotor innervation dysfunction of the leptomeninx arteries that may result in the hemodynamic disturbances.

  4. Compliance effects on small diameter polyurethane graft patency.

    PubMed

    Uchida, N; Kambic, H; Emoto, H; Chen, J F; Hsu, S; Murabayshi, S; Harasaki, H; Nosé, Y

    1993-10-01

    Microporous compliance matched and noncompliant grafts were compared in a dog carotid artery interposition model. We fabricated 4 mm diameter sponge type polyurethane (Biomer) tubes 5 cm in length with a 0.5 mm wall thickness. The luminal surface was covered with a 50 microns coating of cross-linked gelatin. Compliance was measured in vitro and in vivo by volume and vessel diameter changes. Over a mean arterial pressure range of 55-155 mm Hg, the diameter changes of grafts and stump arteries were measured in situ using an ultrasonic Hokanson device. Compliance matched grafts were found to have the same in vitro compliance values as the natural canine carotid at a mean arterial pressure of 100 mm Hg. Compliance matched and noncompliant grafts had values of 10.3 +/- 1.3 and 0.9 +/- 0.1 x 10(-2) mm Hg, respectively. End to end arterial anastomoses were constructed between the graft and the host arteries. The use of synthetic grafts with matched compliance to the adjacent natural vessels has been advocated as the ideal solution to circumvent the problems of graft failure. These studies indicate that compliance values for compliance matched grafts decreased immediately after implantation (from 10.3 to 6.5 x 10(-2) %/mm Hg) and within 6 weeks decreased to 3.6 x 10(-2) %/mm Hg. The compliance values for noncompliant grafts remained constant throughout the test period. At autopsy all grafts showed a tightly adhered tissue capsule. The thickness of the anastomotic hyperplasia at the distal sites of compliance matched grafts was significantly different (P < .05) than that of the adjacent artery. The patency for compliant and noncompliant grafts was 64% and 50%, respectively. Evidence for polyurethane graft degradation was obtained by Fourier transform infrared spectroscopy and gel permeation chromatography analysis of patent explants. Compliance mismatch alone does not contribute to graft failure, however, material degradation, suture technique and/or capsule formation can play a contributory role although these were not tested directly.

  5. Internal Carotid Artery Hypoplasia: Role of Color-Coded Carotid Duplex Sonography.

    PubMed

    Chen, Pei-Ya; Liu, Hung-Yu; Lim, Kun-Eng; Lin, Shinn-Kuang

    2015-10-01

    The purpose of this study was to determine the role of color-coded carotid duplex sonography for diagnosis of internal carotid artery hypoplasia. We retrospectively reviewed 25,000 color-coded carotid duplex sonograms in our neurosonographic database to establish more diagnostic criteria for internal carotid artery hypoplasia. A definitive diagnosis of internal carotid artery hypoplasia was made in 9 patients. Diagnostic findings on color-coded carotid duplex imaging include a long segmental small-caliber lumen (52% diameter) with markedly decreased flow (13% flow volume) in the affected internal carotid artery relative to the contralateral side but without intraluminal lesions. Indirect findings included markedly increased total flow volume (an increase of 133%) in both vertebral arteries, antegrade ipsilateral ophthalmic arterial flow, and a reduced vessel diameter with increased flow resistance in the ipsilateral common carotid artery. Ten patients with distal internal carotid artery dissection showed a similar color-coded duplex pattern, but the reductions in the internal and common carotid artery diameters and increase in collateral flow from the vertebral artery were less prominent than those in hypoplasia. The ipsilateral ophthalmic arterial flow was retrograde in 40% of patients with distal internal carotid artery dissection. In addition, thin-section axial and sagittal computed tomograms of the skull base could show the small diameter of the carotid canal in internal carotid artery hypoplasia and help distinguish hypoplasia from distal internal carotid artery dissection. Color-coded carotid duplex sonography provides important clues for establishing a diagnosis of internal carotid artery hypoplasia. A hypoplastic carotid canal can be shown by thin-section axial and sagittal skull base computed tomography to confirm the final diagnosis. © 2015 by the American Institute of Ultrasound in Medicine.

  6. Hyaluronic acid enhancement of expanded polytetrafluoroethylene for small diameter vascular grafts

    NASA Astrophysics Data System (ADS)

    Lewis, Nicole R.

    Cardiovascular disease is the leading cause of mortality and morbidity in the United States and other developed countries. In the United States alone, 8 million people are diagnosed with peripheral arterial disease per year and over 250,000 patients have coronary bypass surgery each year. Autologous blood vessels are the standard graft used in small diameter (<6mm) arterial bypass procedures. Synthetic small diameter grafts have had limited success. While polyethylene (Dacron) and expanded polytetrafluoroethylene (ePTFE) are the most commonly used small diameter synthetic vascular graft materials, there are significant limitations that make these materials unfavorable for use in the low blood flow conditions of the small diameter arteries. Specifically, Dacron and ePTFE grafts display failure due to early thrombosis or late intimal hyperplasia. With the shortage of tissue donors and the limited supply of autologous blood vessels available, there is a need for a small diameter synthetic vascular graft alternative. The aim of this research is to create and characterize ePTFE grafts prepared with hyaluronic acid (HA), evaluate thrombogenic potential of ePTFE-HA grafts, and evaluate graft mechanical properties and coating durability. The results in this work indicate the successful production of ePTFE-HA materials using a solvent infiltration technique. Surface interactions with blood show increased platelet adhesion on HA-modified surfaces, though evidence may suggest less platelet activation and erythrocyte lysis. Significant changes in mechanical properties of HA-modified ePTFE materials were observed. Further investigation into solvent selection, uniformity of HA, endothelialization, and dynamic flow testing would be beneficial in the evaluation of these materials for use in small diameter vascular graft bypass procedures.

  7. Piezo1 in Smooth Muscle Cells Is Involved in Hypertension-Dependent Arterial Remodeling.

    PubMed

    Retailleau, Kevin; Duprat, Fabrice; Arhatte, Malika; Ranade, Sanjeev Sumant; Peyronnet, Rémi; Martins, Joana Raquel; Jodar, Martine; Moro, Céline; Offermanns, Stefan; Feng, Yuanyi; Demolombe, Sophie; Patel, Amanda; Honoré, Eric

    2015-11-10

    The mechanically activated non-selective cation channel Piezo1 is a determinant of vascular architecture during early development. Piezo1-deficient embryos die at midgestation with disorganized blood vessels. However, the role of stretch-activated ion channels (SACs) in arterial smooth muscle cells in the adult remains unknown. Here, we show that Piezo1 is highly expressed in myocytes of small-diameter arteries and that smooth-muscle-specific Piezo1 deletion fully impairs SAC activity. While Piezo1 is dispensable for the arterial myogenic tone, it is involved in the structural remodeling of small arteries. Increased Piezo1 opening has a trophic effect on resistance arteries, influencing both diameter and wall thickness in hypertension. Piezo1 mediates a rise in cytosolic calcium and stimulates activity of transglutaminases, cross-linking enzymes required for the remodeling of small arteries. In conclusion, we have established the connection between an early mechanosensitive process, involving Piezo1 in smooth muscle cells, and a clinically relevant arterial remodeling. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  8. Brain Arterial Diameters as a Risk Factor for Vascular Events.

    PubMed

    Gutierrez, Jose; Cheung, Ken; Bagci, Ahmet; Rundek, Tatjana; Alperin, Noam; Sacco, Ralph L; Wright, Clinton B; Elkind, Mitchell S V

    2015-08-06

    Arterial luminal diameters are routinely used to assess for vascular disease. Although small diameters are typically considered pathological, arterial dilatation has also been associated with disease. We hypothesize that extreme arterial diameters are biomarkers of the risk of vascular events. Participants in the Northern Manhattan Study who had a time-of-flight magnetic resonance angiography were included in this analysis (N=1034). A global arterial Z-score, called the brain arterial remodeling (BAR) score, was obtained by averaging the measured diameters within each individual. Individuals with a BAR score <-2 SDs were considered to have the smallest diameters, individuals with a BAR score >-2 and <2 SDs had average diameters, and individuals with a BAR score >2 SDs had the largest diameters. All vascular events were recorded prospectively after the brain magnetic resonance imaging. Spline curves and incidence rates were used to test our hypothesis. The association of the BAR score with death (P=0.001), vascular death (P=0.02), any vascular event (P=0.05), and myocardial infarction (P=0.10) was U-shaped except for ischemic stroke (P=0.74). Consequently, incidence rates for death, vascular death, myocardial infarction, and any vascular event were higher in individuals with the largest diameters, whereas individuals with the smallest diameters had a higher incidence of death, vascular death, any vascular event, and ischemic stroke compared with individuals with average diameters. The risk of death, vascular death, and any vascular event increased at both extremes of brain arterial diameters. The pathophysiology linking brain arterial remodeling to systemic vascular events needs further research. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  9. Microfluidic strategy to investigate dynamics of small blood vessel function

    NASA Astrophysics Data System (ADS)

    Yasotharan, Sanjesh; Bolz, Steffen-Sebastian; Guenther, Axel

    2010-11-01

    Resistance arteries (RAs, 30-300 microns in diameter) that are located within the terminal part of the vascular tree regulate the laminar perfusion of tissue with blood, via the peripheral vascular resistance, and hence controls the systemic blood pressure. The structure of RAs is adapted to actively controlling flow resistance by dynamically changing their diameter, which is non-linearly dependent on the temporal variation of the transmural pressure, perfusion flow rate and spatiotemporal changes in the chemical environment. Increases in systemic blood pressure (hypertension) resulting from pathologic changes in the RA response represent the primary risk factor for cardiovascular diseases. We use a microfluidic strategy to investigate small blood vessels by quantifying structural variations within the arterial wall, RA outer contour and diameter over time. First, we document the artery response to vasomotor drugs that were homogeneously applied at step-wise increasing concentration. Second, we investigate the response in the presence of well-defined axial and circumferential heterogeneities. Artery per- and superfusion is discussed based on microscale PIV measurements of the fluid velocity on both sides of the arterial wall. Structural changes in the arterial wall are quantified using cross-correlation and proper orthogonal decomposition analyses of bright-field micrographs.

  10. Neurokinin-induced changes in pial artery diameter in the anaesthetized guinea-pig.

    PubMed Central

    Beattie, D. T.; Stubbs, C. M.; Connor, H. E.; Feniuk, W.

    1993-01-01

    1. The effects of selective neurokinin agents on pial artery diameter, measured with an on-line image analyser, have been studied in anaesthetized guinea-pigs in order to characterize the neurokinin receptors present on pial arteries. 2. Perivascular injection of either substance P (0.01-1 microM) or the selective NK1 receptor agonists, substance P methyl ester (SPOMe, 0.01-1 microM) and GR73632 (0.1 microM), increased pial artery diameter. 3. In contrast, the selective NK2 receptor agonist, GR64349 (1 microM), produced a small vasoconstriction while the NK3 receptor-selective agonist, senktide (1 microM) was inactive. 4. Co-administration of GR82334 (1 microM), a selective NK1 receptor antagonist, inhibited the vasodilatation produced by SPOMe (0.1 microM) but not that caused by calcitonin gene-related peptide (CGRP, 0.01 microM). 5. The results are consistent with an involvement of NK1 receptors in the neurokinin-induced increase in guinea-pig pial artery diameter. PMID:7679026

  11. Evaluation of different diameter arterial tubing and arterial cannulae in simulated neonatal/pediatric cardiopulmonary bypass circuits.

    PubMed

    Wang, Shigang; Rosenthal, Tami; Kunselman, Allen R; Ündar, Akif

    2015-01-01

    The objective of this study is to evaluate three different diameters of arterial tubing and three diameters of arterial cannulae in terms of pressure drop, and hemodynamic energy delivery in simulated neonatal/pediatric cardiopulmonary bypass (CPB) circuits. The CPB circuit consisted of a Terumo Capiox Baby FX05 oxygenator (Terumo Corporation, Tokyo, Japan), arterial tubing (1/4 in, 3/16 in, or 1/8 in × 150 cm), and a Medtronic Bio-Medicus arterial cannula (8, 10, or 12 Fr; Medtronic, Inc., Minneapolis, MN, USA). The pseudo patient's pressure was maintained at 50 mm Hg. The circuit was primed using lactated Ringer's solution and heparinized packed human red blood cells (hematocrit 30%). Trials were conducted at different flow rates and temperatures (35 and 28°C). Flow and pressure data were collected using a custom-based data acquisition system. Using 8 Fr arterial cannula at 500 mL/min, small diameter arterial tubing generated higher circuit pressure (294.6 ± 0.1 mm Hg [1/8 in], 213.5 ± 0.5 mm Hg [3/16 in], 208.4 ± 0.4 mm Hg [1/4 in] at 35°C) and arterial line pressure drop (158.3 ± 0.1 mm Hg [1/8 in], 79.6 ± 0.1 mm Hg [3/16 in], 62.1 ± 0.1 mm Hg [1/4 in] at 35°C). Using 10 Fr arterial cannula at 1000 mL/min, pre-oxygenator pressures were 266.8 ± 0.2 mm Hg (3/16 in) and 248.0 ± 0.3 mm Hg (1/4 in); arterial line pressure drops were 111.6 ± 0.0 mm Hg (3/16 in) and 74.0 ± 0.1 mm Hg (1/4 in) at 35°C. When using 12 Fr arterial cannula at 1500 mL/min, preoxygenator pressures reached 324.4 ± 0.3 mm Hg (3/16 in) and 302.5 ± 0.4 mm Hg (1/4 in); arterial line pressure drops were 154.0 ± 0.1 mm Hg (3/16 in) and 92.0 ± 0.2 mm Hg (1/4 in) at 35°C. Pressure drops across arterial line tubing were main CPB circuit pressure drops. High flow rate, hypothermia, small diameter arterial tubing. and arterial cannula created more hemodynamic energy at the preoxygenator site, but energy loss across CPB circuit also increased. Although small diameter (<1/4 in ID) arterial tubing may decrease total CPB priming volume, it also led to significantly higher circuit pressure, higher pressure drop, and more hemodynamic energy loss across CPB circuit. Larger diameter arterial cannula had less pressure drop and allowed more hemodynamic energy delivery to the patient. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  12. Endothelial epithelial sodium channel inhibition activates endothelial nitric oxide synthase via phosphoinositide 3-kinase/Akt in small-diameter mesenteric arteries.

    PubMed

    Pérez, Francisco R; Venegas, Fabiola; González, Magdalena; Andrés, Sergio; Vallejos, Catalina; Riquelme, Gloria; Sierralta, Jimena; Michea, Luis

    2009-06-01

    Recent studies have shown that the epithelial sodium channel (ENaC) is expressed in vascular tissue. However, the role that ENaC may play in the responses to vasoconstrictors and NO production has yet to be addressed. In this study, the contractile responses of perfused pressurized small-diameter rat mesenteric arteries to phenylephrine and serotonin were reduced by ENaC blockade with amiloride (75.1+/-3.2% and 16.9+/-2.3% of control values, respectively; P<0.01) that was dose dependent (EC(50)=88.9+/-1.6 nmol/L). Incubation with benzamil, another ENaC blocker, had similar effects. alpha, beta, and gamma ENaC were identified in small-diameter rat mesenteric arteries using RT-PCR and Western blot with specific antibodies. In situ hybridization and immunohistochemistry localized ENaC expression to the tunica media and endothelium of small-diameter rat mesenteric arteries. Patch-clamp experiments demonstrated that primary cultures of mesenteric artery endothelial cells expressed amiloride-sensitive sodium currents. Mechanical ablation of the endothelium or inhibition of eNOS with N(omega)-nitro-L-arginine inhibited the reduction in contractility caused by ENaC blockers. ENaC inhibitors increased eNOS phosphorylation (Ser 1177) and Akt phosphorylation (Ser 473). The presence of the phosphoinositide 3-kinase inhibitor LY294002 blunted Akt phosphorylation and eNOS phosphorylation and the decrease in the response to phenylephrine caused by blockers of ENaC, indicating that the phosphoinositide 3-kinase/Akt pathway was activated after ENaC inhibition. Finally, we observed that the effects of blockers of ENaC were flow dependent and that the vasodilatory response to shear stress was enhanced by ENaC blockade. Our results identify a previously unappreciated role for ENaC as a negative modulator of eNOS and NO production in resistance arteries.

  13. [Introduction and advantage analysis of the stepwise method for the construction of vascular trees].

    PubMed

    Zhang, Yan; Xie, Haiwei; Zhu, Kai

    2010-08-01

    A new method for constructing the model of vascular trees was proposed in this paper. By use of this method, the arterial trees in good agreement with the actual structure could be grown. In this process, all vessels in the vascular tree were divided into two groups: the conveying vessels, and the delivering branches. And different branches could be built by different ways. Firstly, the distributing rules of conveying vessels were ascertained by use of measurement data, and then the conveying vessels were constructed in accordance to the statistical rule and optimization criterion. Lastly, delivering branches were modeled by constrained constructive optimization (CCO) on the conveying vessel-trees which had already been generated. In order to compare the CCO method and stepwise method proposed here, two 3D arterial trees of human tongue were grown with their vascular tree having a special structure. Based on the corrosion casts of real arterial tree of human tongue, the data about the two trees constructed by different methods were compared and analyzed, including the averaged segment diameters at respective levels, the distribution and the diameters of the branches of first level at respective directions. The results show that the vascular tree built by stepwise method is more similar to the true arterial of human tongue when compared against the tree built by CCO method.

  14. Protection against high intravascular pressure in giraffe legs.

    PubMed

    Petersen, Karin K; Hørlyck, Arne; Ostergaard, Kristine H; Andresen, Joergen; Broegger, Torbjoern; Skovgaard, Nini; Telinius, Niklas; Laher, Ismael; Bertelsen, Mads F; Grøndahl, Carsten; Smerup, Morten; Secher, Niels H; Brøndum, Emil; Hasenkam, John M; Wang, Tobias; Baandrup, Ulrik; Aalkjaer, Christian

    2013-11-01

    The high blood pressure in giraffe leg arteries renders giraffes vulnerable to edema. We investigated in 11 giraffes whether large and small arteries in the legs and the tight fascia protect leg capillaries. Ultrasound imaging of foreleg arteries in anesthetized giraffes and ex vivo examination revealed abrupt thickening of the arterial wall and a reduction of its internal diameter just below the elbow. At and distal to this narrowing, the artery constricted spontaneously and in response to norepinephrine and intravascular pressure recordings revealed a dynamic, viscous pressure drop along the artery. Histology of the isolated median artery confirmed dense sympathetic innervation at the narrowing. Structure and contractility of small arteries from muscular beds in the leg and neck were compared. The arteries from the legs demonstrated an increased media thickness-to-lumen diameter ratio, increased media volume, and increased numbers of smooth muscle cells per segment length and furthermore, they contracted more strongly than arteries from the neck (500 ± 49 vs. 318 ± 43 mmHg; n = 6 legs and neck, respectively). Finally, the transient increase in interstitial fluid pressure following injection of saline was 5.5 ± 1.7 times larger (n = 8) in the leg than in the neck. We conclude that 1) tissue compliance in the legs is low; 2) large arteries of the legs function as resistance arteries; and 3) structural adaptation of small muscle arteries allows them to develop an extraordinary tension. All three findings can contribute to protection of the capillaries in giraffe legs from a high arterial pressure.

  15. A system for real-time measurement of the brachial artery diameter in B-mode ultrasound images.

    PubMed

    Gemignani, Vincenzo; Faita, Francesco; Ghiadoni, Lorenzo; Poggianti, Elisa; Demi, Marcello

    2007-03-01

    The measurement of the brachial artery diameter is frequently used in clinical studies for evaluating the flow-mediated dilation and, in conjunction with the blood pressure value, for assessing arterial stiffness. This paper presents a system for computing the brachial artery diameter in real-time by analyzing B-mode ultrasound images. The method is based on a robust edge detection algorithm which is used to automatically locate the two walls of the vessel. The measure of the diameter is obtained with subpixel precision and with a temporal resolution of 25 samples/s, so that the small dilations induced by the cardiac cycle can also be retrieved. The algorithm is implemented on a standalone video processing board which acquires the analog video signal from the ultrasound equipment. Results are shown in real-time on a graphical user interface. The system was tested both on synthetic ultrasound images and in clinical studies of flow-mediated dilation. Accuracy, robustness, and intra/inter observer variability of the method were evaluated.

  16. X-ray intravital microscopy for functional imaging in rat hearts using synchrotron radiation coronary microangiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Umetani, K.; Fukushima, K.

    2013-03-15

    An X-ray intravital microscopy technique was developed to enable in vivo visualization of the coronary, cerebral, and pulmonary arteries in rats without exposure of organs and with spatial resolution in the micrometer range and temporal resolution in the millisecond range. We have refined the system continually in terms of the spatial resolution and exposure time. X-rays transmitted through an object are detected by an X-ray direct-conversion type detector, which incorporates an X-ray SATICON pickup tube. The spatial resolution has been improved to 6 {mu}m, yielding sharp images of small arteries. The exposure time has been shortened to around 2 msmore » using a new rotating-disk X-ray shutter, enabling imaging of beating rat hearts. Quantitative evaluations of the X-ray intravital microscopy technique were extracted from measurements of the smallest-detectable vessel size and detection of the vessel function. The smallest-diameter vessel viewed for measurements is determined primarily by the concentration of iodinated contrast material. The iodine concentration depends on the injection technique. We used ex vivo rat hearts under Langendorff perfusion for accurate evaluation. After the contrast agent is injected into the origin of the aorta in an isolated perfused rat heart, the contrast agent is delivered directly into the coronary arteries with minimum dilution. The vascular internal diameter response of coronary arterial circulation is analyzed to evaluate the vessel function. Small blood vessels of more than about 50 {mu}m diameters were visualized clearly at heart rates of around 300 beats/min. Vasodilation compared to the control was observed quantitatively using drug manipulation. Furthermore, the apparent increase in the number of small vessels with diameters of less than about 50 {mu}m was observed after the vasoactive agents increased the diameters of invisible small blood vessels to visible sizes. This technique is expected to offer the potential for direct investigation of mechanisms of vascular dysfunctions.« less

  17. Stretch-induced contraction in pulmonary arteries.

    PubMed

    Kulik, T J; Evans, J N; Gamble, W J

    1988-12-01

    Stretch stimulates contraction of systemic blood vessels, but the response has not been described in pulmonary vessels. To determine whether pulmonary arteries contract when stretched, isolated cylindrical segments of pulmonary arteries were suspended between two parallel wires, stretched, and the active force was generated in response to stretch measured. Eighty-nine percent of segments from small (in situ diameter less than 1,000 microns) feline pulmonary arteries contracted when stretched, and in 65% of these the magnitude of stretch was related to the magnitude of contraction. Large (in situ diameter greater than or equal to 1,000 microns) feline pulmonary arteries did not contract with stretch. Multiple, rapidly repeated stretches resulted in a diminution of active force development. Stretch-induced contraction required external Ca2+ and was abolished by diltiazem (10 microns), but it was not affected by phenoxybenzamine, phentolamine, diethylcarbamazine, or mechanical removal of endothelium. Indomethacin blunted but did not abolish stretch-induced contraction, an effect that may have been nonspecific. This study suggests that stretch can act, probably directly, on smooth muscle in small feline pulmonary arteries to elicit contraction and that it may be a determinant of pulmonary vascular tone. In addition, feline pulmonary arteries are suitable for the in vitro study of stretch-induced contraction.

  18. 4D flow MRI assessment of extracranial-intracranial bypass: qualitative and quantitative evaluation of the hemodynamics.

    PubMed

    Sekine, Tetsuro; Takagi, Ryo; Amano, Yasuo; Murai, Yasuo; Orita, Erika; Matsumura, Yoshio; Kumita, Shin-Ichiro

    2016-03-01

    Our aim was to assess the feasibility of using time-resolved 3D phase-contrast (4D flow) MRI to characterize extracranial-intracranial (EC-IC) bypass. We enrolled 32 patients who underwent EC-IC bypass (15 men, 17 women; mean age 66.4 years). In all, 16 underwent radial artery graft (RAG) bypass and 16 underwent superficial temporal artery (STA) bypass. 4D flow MRI, time-of-flight (TOF) magnetic resonance angiography (MRA), and computed tomography angiography (CTA) were performed. Bypass patency, flow direction, and blood flow volume (BFV) of each artery were determined by 4D flow MRI. Arterial diameters were measured by TOF-MRA and CTA. We compared RAG and STA bypasses by evaluating the flow direction and BFV of each artery. We evaluated the correlation between arterial diameters (measured by CTA or MRA) and the BFV and the detectability of flow direction (measured by 4D flow MRI) of each artery. 4D flow MRI confirmed the patency of each bypass artery. Flow direction of the M1 segment of the middle cerebral artery and BFV in the bypass artery differed between RAG and STA groups (p < 0.01). BFV in the bypass slightly correlated with the diameters on CTA (p < 0.05, R (2) = 0.287). Of the 29 arteries in the circle of Willis, nine were not depicted on 4D flow MRI. Cutoff values for arterial diameters on CTA and TOF-MRA for detecting the artery on 4D flow MRI were 2.4 and 1.8 mm, respectively. 4D flow MRI provided unique information for characterizing EC-IC bypasses, although this detectability is limited when addressing small arteries with slow flow.

  19. Prostatic Artery Embolization for Enlarged Prostates Due to Benign Prostatic Hyperplasia. How I Do It

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carnevale, Francisco C., E-mail: fcarnevale@uol.com.br; Antunes, Alberto A., E-mail: antunesuro@uol.com.br

    2013-12-15

    Prostatic artery embolization (PAE) has emerged as an alternative to surgical treatments for benign prostatic hyperplasia (BPH). Patient selection and refined technique are essential for good results. Urodynamic evaluation and magnetic resonance imaging are very important and technical limitations are related to elderly patients with tortuous and atherosclerotic vessels, anatomical variations, difficulty visualizing and catheterizing small diameter arteries feeding the prostate, and the potential risk of bladder and rectum ischemia. The use of small-diameter hydrophilic microcatheters is mandatory. Patients can be treated safely by PAE with low rates of side effects, reducing prostate volume with clinical symptoms and quality ofmore » life improvement without urinary incontinence, ejaculatory disorders, or erectile dysfunction. A multidisciplinary approach with urologists and interventional radiologists is essential to achieve better results.« less

  20. [Applied anatomy of small saphenous vein and its distally-based sural nerve nutrient].

    PubMed

    Zhang, Fahui; Lin, Songqing; Zheng, Heping

    2005-07-01

    To investigate the origin of small saphenous vein of distally-based of sural nerve nutrient vessels flap and its clinical application. The origins of nutrient vessels of small saphenous vein and communicating branches of superficial-deep vein were observed on specimens of 30 adult cadaveric low limbs by perfusing red gelatin to dissect the artery. The nutrient vessels of small saphenous vein originated from the heel lateral artery, the terminal perforator branches of peroneal artery and intermuscular septum perforating branches of peroneal artery. There were 2 to 5 branches of such distally-based perforating branches whose diameters ranged from 0.6 to 1.0 mm. Those perforating branches included fascia branches, cutaneous branches nerve and vein nutrient branches. Those nutrient vessels formed a longitudinal vessel chain of clinical nerve shaft, vessel chain of vein side and vessel network of deep superficial fascia. The small saphenous vein had 1 to 2 communicating branches of superficial-deep vein whose diameter was 1.7+/-0.5 mm, 3.4+/-0.9 cm to the level of cusp of lateral malleolus, and converged into the fibular vein. Distally-based sural nerve, small saphenous vein, and nutrient vessels of fascia skin have the same region. The communicating branches of superficial-deep vein is 3 to 4 cm to the level of cusp lateral malleolus. These communicating branches could improve the venous drainage of the flap.

  1. Ryanodine receptors regulate arterial diameter and wall [Ca2+] in cerebral arteries of rat via Ca2+-dependent K+ channels

    PubMed Central

    Knot, Harm J; Standen, Nicholas B; Nelson, Mark T

    1998-01-01

    The effects of inhibitors of ryanodine-sensitive calcium release (RyR) channels in the sarcoplasmic reticulum (SR) and Ca2+-dependent potassium (KCa) channels on the membrane potential, intracellular [Ca2+], and diameters of small pressurized (60 mmHg) cerebral arteries (100–200 μm) were studied using digital fluorescence video imaging of arterial diameter and wall [Ca2+], combined with microelectrode measurements of arterial membrane potential. Ryanodine (10 μm), an inhibitor of RyR channels, depolarized by 9 mV, increased intracellular [Ca2+] by 46 nm and constricted pressurized (to 60 mmHg) arteries with myogenic tone by 44 μm (∼22 %). Iberiotoxin (100 nm), a blocker of KCa channels, under the same conditions, depolarized the arteries by 10 mV, increased arterial wall calcium by 51 nm, and constricted by 37 μm (∼19 %). The effects of ryanodine and iberiotoxin were not additive and were blocked by inhibitors of voltage-dependent Ca2+ channels. Caffeine (10 mm), an activator of RyR channels, transiently increased arterial wall [Ca2+] by 136 ± 9 nm in control arteries and by 158 ± 12 nm in the presence of iberiotoxin. Caffeine was relatively ineffective in the presence of ryanodine, increasing [calcium] by 18 ± 5 nm. In the presence of blockers of voltage-dependent Ca2+ channels (nimodipine, diltiazem), ryanodine and inhibitors of the SR calcium ATPase (thapsigargin, cyclopiazonic acid) were without effect on arterial wall [Ca2+] and diameter. These results suggest that local Ca2+ release originating from RyR channels (Ca2+ sparks) in the SR of arterial smooth muscle regulates myogenic tone in cerebral arteries solely through activation of KCa channels, which regulate membrane potential through tonic hyperpolarization, thus limiting Ca2+ entry through L-type voltage-dependent Ca2+ channels. KCa channels therefore act as a negative feedback control element regulating arterial diameter through a reduction in global intracellular free [Ca2+]. PMID:9490841

  2. Bottom-up fabrication of artery-mimicking tubular co-cultures in collagen-based microchannel scaffolds.

    PubMed

    Tan, A; Fujisawa, K; Yukawa, Y; Matsunaga, Y T

    2016-10-20

    We developed a robust bottom-up approach to construct open-ended, tubular co-culture constructs that simulate the human vascular morphology and microenvironment. By design, these three-dimensional artificial vessels mimic the basic architecture of an artery: a collagen-rich extracellular matrix (as the tunica externa), smooth muscle cells (SMCs) (as the tunica media), and an endothelial cell (EC) lining (as the tunica interna). A versatile needle-based fabrication technique was employed to achieve controllable arterial layouts within a PDMS-hosted collagen microchannel scaffold (330 ± 10 μm in diameter): (direct co-culture) a SMC/EC bilayer to follow the structure of an arteriole-like segment; and (encapsulated co-culture) a lateral SMC multilayer covered by an EC monolayer lining to simulate the architecture of a larger artery. Optical and fluorescence microscopy images clearly evidenced the progressive cell elongation and sprouting behavior of SMCs and ECs along the collagen gel contour and within the gel matrix under static co-culture conditions. The progressive cell growth patterns effectively led to the formation of a tubular co-culture with an internal endothelial lining expressing prominent CD31 (cluster of differentiation 31) intercellular junction markers. During a 4-day static maturation period, the artery constructs showed modest alteration in the luminal diameters (i.e. less than 10% changes from the initial measurements). This argues in favor of stable and predictable arterial architecture achieved via the proposed fabrication protocols. Both co-culture models showed a high glucose metabolic rate during the initial proliferation phase, followed by a temporary quiescent (and thus, mature) stage. These proof-of-concept models with a controllable architecture create an important foundation for advanced vessel manipulations such as the integration of relevant physiological functionality or remodeling into a vascular disease-mimicking tissue.

  3. Wall-to-lumen ratio of intracranial arteries measured by indocyanine green angiography

    PubMed Central

    Nakagawa, Daichi; Shojima, Masaaki; Yoshino, Masanori; Kin, Taichi; Imai, Hideaki; Nomura, Seiji; Saito, Toki; Nakatomi, Hirofumi; Oyama, Hiroshi; Saito, Nobuhito

    2016-01-01

    Background: The wall-to-lumen ratio (WLR) is an important parameter in vascular medicine because it indicates the character of vascular wall as well as the degree of stenosis. Despite the advances in medical imaging technologies, it is still difficult to measure the thin-walled normal intracranial arteries, and the reports on the WLR of normal intracranial artery are limited. It might be possible to calculate the WLR using the indocyanine green (ICG) angiography, which is used to observe intracranial vessels during microsurgery. Purpose: To evaluate the WLR of normal intracranial arteries using ICG angiography. Materials and Methods: From the three cases in which ICG angiography was recorded with a ruler during microsurgery, 20 measurement points were chosen for the analysis. The ICG was injected intravenously with a dose of 0.2 mg/kg, and the vessels were inspected at high magnification using an operating microscope equipped with near-infrared illumination system. The vessel outer diameter and the luminal diameter were measured using the images before and after the ICG arrival based on the pixel ratio method using a ruler as reference, respectively. The WLR was calculated as 0.5 × (vessel outer diameter − vessel luminal diameter). Results: The WLR (mean ± standard deviation) of normal intracranial arteries was 0.086 ± 0.022. The WLR tended to be high in small arteries. Conclusion: The WLR of normal intracranial arteries calculated using ICG angiography was consistent with the WLR reported in the previous reports based on human autopsy. PMID:27695538

  4. Catheter Closure Through a Venous Approach of Patent Ductus Arteriosus in Small Pediatric Patients Using Combined Angiographic and Echocardiographic Guidance.

    PubMed

    Thanopoulos, Basil Vasilios D; Ninios, Vlassis; Dardas, Petros; Giannopoulos, Andreas; Deleanou, Dan; Iancovici, Silvia

    2016-11-15

    The standard technique of catheter closure of patent ductus arteriosus (PDA) may be associated with arterial complications particularly in small pediatric patients. The aim of this study was to evaluate whether catheter closure of PDA in small children using an exclusive venous approach is a safe and effective alternative to closure with the standard technique. One hundred-twelve patients, aged 2 to 24 months, were randomly assigned in a 1:1 ratio to catheter closure of PDA using the standard technique (group 1) and an exclusive venous approach (group 2), respectively. In group 2, the procedure was guided using hand injections of contrast media through the delivery sheath and 2-dimensional and color Doppler echocardiography. Group 1: the PDA diameter ranged from 2 to 5.5 mm and the device diameter ranged from 4 to 8 mm. The PDA occluders were permanently implanted in all patients. Five losses of the arterial pulses that were restored with intravenous infusion of heparin and recombinant tissue plasminogen activator (rtPA), and 4 groin hematomas were the main complications of the procedure. Group 2: the mean PDA diameter ranged from 2.5 to 6 mm and the device diameter ranged from 3 to 8 mm. The PDA occluders were permanently implanted in all but 2 patients. There were no complications. Complete echocardiographic closure of PDA at 1-month follow-up was observed in all 110 patients. Exclusive transvenous PDA occlusion is an effective and safe technique that prevents the arterial complications of the standard approach in small children. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Feasibility of recanalization of human coronary arteries using high-intensity ultrasound.

    PubMed

    Ernst, A; Schenk, E A; Woodlock, T J; Alliger, H; Gottlieb, S; Child, S Z; Meltzer, R S

    1994-01-15

    To investigate the feasibility of ultrasonic recanalization of obstructed human coronary arteries in vitro, high-intensity ultrasound was applied to 16 coronary arteries obtained at autopsy, using a prototype instrument enabling insonification through a catheter tip. It was a 119 cm long, 0.95 mm thick wire in an 8Fr catheter connected to an external ultrasonic transformer and power generator. A 5 MHz phased-array 2-dimensional echocardiography instrument was used to determine minimal luminal diameter and percent diameter narrowing before and after ultrasound application. The ultrasonic energy was delivered at 21.5 kHz and with a 52 +/- 19 micrometer average amplitude of tip displacement. The mean percent luminal diameter narrowing, flow rate and mean pressure gradient before ultrasound exposure were 74 +/- 11%, 97 +/- 61 ml/min, and 92 +/- 18 mm Hg, respectively. After recanalization, the mean percent luminal diameter narrowing decreased to 45 +/- 17% (p < 0.001), the mean flow rate increased to 84 +/- 92 ml/min (p < 0.001), and the mean pressure gradient was reduced to 45 +/- 24 mm Hg (p < 0.001). Of the debris particles, 95% had a diameter < 9 microns (range 5 to 12). Arterial perforation occurred in 5 of 16 arteries (31%) and all 5 occurred due to stiff wire manipulation and without ultrasound application. Mechanical fracture of the wire occurred in 8 cases (50%). No signs of thermal injury were found on histology. Thus, ultrasonic recanalization of human coronary arteries in vitro is feasible. It may reduce obstruction and improve blood flow. Debris sizes are sufficiently small to minimize the hazard of peripheral embolization.

  6. Preoperative ultrasound still valuable for radio-cephalic arteriovenous fistula creation?

    PubMed

    Pajek, Jernej; Malovrh, Marko

    2017-03-06

    Radio-cephalic arteriovenous fistula is a prototype hemodialysis access with small incidences of infection and distal ischemia, it spares proximal veins for future access use and it helps in the maturation of veins that may be used for more proximal access creations. This access type is prone to higher early failure rates compared to more proximal fistulas and there are unsolved uncertainties regarding exact ultrasound parameters predictive of fistula outcome. Evolution of ultrasound use has yielded several functional parameters that can be measured in addition to anatomical lumen sizes, which remain core parameters on which the decision to construct fistula in radio-cephalic forearm position is based. We propose to use arterial hyperemic response and wall morphology to aid in this decision when radial artery diameter falls in the interval with predictive uncertainty of 1.6-1.9 mm and to use venous flow pattern, respiratory variation, radial artery status and possibly venous distensibility when cephalic vein augmented diameter lies in the borderline interval of 2-2.4 mm. Ultrasound preoperative mapping and planning should be followed by expert surgical technique and several technique modifications of the classical end-to-side approach are possible to enhance operation outcome and diminish the incidence of stenosis most often present at juxta-anastomotic location. In our experience radio-cephalic arteriovenous fistula remains the golden standard for hemodialysis access and preoperative ultrasound the single best imaging modality to plan the operation and predict its success.

  7. Renal artery anatomy assessed by quantitative analysis of selective renal angiography in 1,000 patients with hypertension.

    PubMed

    Lauder, Lucas; Ewen, Sebastian; Tzafriri, Abraham Rami; Edelman, Elazer Reuven; Lüscher, Thomas Felix; Blankenstijn, Peter J; Dörr, Oliver; Schlaich, Markus; Sharif, Faisal; Voskuil, Michiel; Zeller, Thomas; Ukena, Christian; Scheller, Bruno; Böhm, Michael; Mahfoud, Felix

    2018-05-20

    With increasing attention to renovascular causes and targets for hypertension there arises a critical need for more detailed knowledge of renal arterial anatomy. However, a standardised nomenclature is lacking. The present study sought to develop a standardised nomenclature for renal anatomy considering the complexity and variation of the renal arterial tree and to assess the applicability of the nomenclature. One thousand hypertensive patients underwent invasive selective renal artery angiography in nine centres. Further, renovasography was performed in 249 healthy swine as a surrogate for normotensive anatomy. Anatomical parameters were assessed by quantitative vascular analysis. Patients' mean blood pressure was 168/90±26/17 mmHg. The right main renal artery was longer than the left (41±15 mm vs. 35±13 mm, p<0.001), but the left had a greater diameter (5.4±1.2 vs. 5.2±1.2 mm, p<0.001). Accessory renal arteries and renal artery disease were documented in 22% and 9% of the patients, respectively. Other than exhibiting a longer left main renal artery in uncontrolled hypertensives (+2.7 mm, p=0.034) there was no anatomical difference between patients with controlled and uncontrolled hypertension. Main renal artery mean diameter was smaller in patients with impaired kidney function (GFR <90 ml/min, left -0.5 mm, right -0.4 mm, both p<0.001). Renal arterial anatomy differs between sides but shows no difference between patients with and without blood pressure control. Impaired GFR was associated with small main renal artery diameter.

  8. Elasticity assessment of electrospun nanofibrous vascular grafts: a comparison with femoral ovine arteries.

    PubMed

    Bagnasco, D Suarez; Ballarin, F Montini; Cymberknop, L J; Balay, G; Negreira, C; Abraham, G A; Armentano, R L

    2014-12-01

    Development of successful small-diameter vascular grafts constitutes a real challenge to biomaterial engineering. In most cases these grafts fail in-vivo due to the presence of a mechanical mismatch between the native vessel and the vascular graft. Biomechanical characterization of real native vessels provides significant information for synthetic graft development. Electrospun nanofibrous vascular grafts emerge as a potential tailor made solution to this problem. PLLA-electrospun nanofibrous tubular structures were prepared and selected as model bioresorbable grafts. An experimental setup, using gold standard and high resolution ultrasound techniques, was adapted to characterize in vitro the poly(L-lactic acid) (PLLA) electrospun structures. The grafts were subjected to near physiologic pulsated pressure conditions, following the pressure-diameter loop approach and the criteria stated in the international standard for cardiovascular implants-tubular vascular prostheses. Additionally, ovine femoral arteries were subjected to a similar evaluation. Measurements of pressure and diameter variations allowed the estimation of dynamical compliance (%C, 10(-2) mmHg) and the pressure-strain elastic modulus (E(Pε), 10(6) dyn cm(-2)) of the abovementioned vessels (grafts and arteries). Nanofibrous PLLA showed a decrease in %C (1.38±0.21, 0.93±0.13 and 0.76±0.15) concomitant to an increase in EPε (10.57±0.97, 14.31±1.47 and 17.63±2.61) corresponding to pressure ranges of 50 to 90 mmHg, 80 to 120 mmHg and 100 to 150 mmHg, respectively. Furthermore, femoral arteries exhibited a decrease in %C (8.52±1.15 and 0.79±0.20) and an increase in E(Pε) (1.66±0.30 and 15.76±4.78) corresponding to pressure ranges of 50-90 mmHg (elastin zone) and 100-130 mmHg (collagen zone). Arterial mechanics framework, extensively applied in our previous works, was successfully used to characterize PLLA vascular grafts in vitro, although its application can be directly extended to in vivo experiences, in conscious and chronically instrumented animals. The specific design and construction of the electrospun nanofibrous PLLA vascular grafts assessed in this work, showed similar mechanical properties as the ones observed in femoral arteries, at the collagen pressure range. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. The myocardial microangiopathy in human and experimental diabetes mellitus. (A microscopic, ultrastructural, morphometric and computer-assisted symbolic-logic analysis).

    PubMed

    Taşcă, C; Stefăneanu, L; Vasilescu, C

    1986-01-01

    The following microscopical aspects were found in the small intramural arteries in the myocardium of 30 diabetic patients: endothelial proliferations with focal protuberances leading to partial narrowing of the lumen, increased thickness of the arterial wall due to fibrosis and accumulations of neutral mucopolysaccharides: alteration of elastic fibres. Morphometrically, the arterial wall thickness and the arterial diameter were increased whereas the arterial density decreased in the diabetic heart. In 25 rats with streptozotocin-induced diabetes the small intramyocardial arteries were investigated at 11 to 40 weeks of diabetic state. Using morphometrical analysis a constant increase of arterial wall thickness paralleling the diabetes duration was found. Microscopically, the lesions consist in endothelial proliferation with bridging across the vascular lumen and slight perivascular and diffuse fibrosis. Ultrastructurally, the capillary basal lamina was thickened in the diabetic myocardium. In order to investigate the morphometrical data we used symbolic-logic as a decision method, by applying an original computer program based on the Quine-McCluskey algorithm. All our results together with the final symbolic-logic expression suggest that damage of the small intramyocardial arteries plays an important role in the pathogenesis of diabetic cardiomyopathy.

  10. Anatomic characteristics and natural history of renal artery aneurysms during longitudinal imaging surveillance.

    PubMed

    Wayne, Erik J; Edwards, Matthew S; Stafford, Jeanette M; Hansen, Kimberley J; Corriere, Matthew A

    2014-08-01

    Renal artery aneurysms (RAAs) are uncommon, and rates of growth and rupture are unknown. Limited evidence therefore exists to guide clinical management of RAAs, particularly small aneurysms that are asymptomatic. To further characterize the natural history of RAAs, we studied anatomic characteristics and changes in diameter during imaging surveillance. Patients evaluated for native RAAs at a single institution during a 5-year period (July 2008 to July 2013) were identified and analyzed retrospectively. Patients with two or more cross-sectional imaging studies (computed tomography or magnetic resonance imaging) more than 1 month apart were included. Demographic and clinical data were collected from medical records, and anatomic data (including aneurysm diameter, calcification, and location) were obtained from electronic images. Changes in RAA diameters over time were evaluated by plots and Wilcoxon signed rank tests. Sixty-eight RAAs in 55 patients were analyzed. Median follow-up was 19.4 months (interquartile range, 11.2-49.0 months). Mean age at presentation was 61.8 ± 9.8 years, and 73% of patients were women. Hypertension was prevalent among 73% of patients. Multiple RAAs were present in 18% of patients, and 24% also had arterial aneurysms of other splanchnic or iliac vessels. The majority of RAAs were calcified and located at the main renal artery bifurcation. Mean initial aneurysm diameter was 16.0 ± 6.4 mm. Median annualized growth rate was 0.06 mm (interquartile range, -0.07 to 0.33 mm; P = .11). No RAA ruptures or acute symptoms occurred during surveillance, and 10.3% of RAAs were repaired electively. Risk of short-term RAA growth or rupture was low. These findings suggest that annual (or less frequent) imaging surveillance is safe in the majority of patients and do not support pre-emptive repair of asymptomatic, small-diameter RAAs. Copyright © 2014 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  11. Retinal vessel diameter and estimated cerebrospinal fluid pressure in arterial hypertension: the Beijing Eye Study.

    PubMed

    Jonas, Jost B; Wang, Ningli; Wang, Shuang; Wang, Ya Xing; You, Qi Sheng; Yang, Diya; Wei, Wen Bin; Xu, Liang

    2014-09-01

    Hypertensive retinal microvascular abnormalities include an increased retinal vein-to-artery diameter ratio. Because central retinal vein pressure depends on cerebrospinal fluid pressure (CSFP), we examined whether the retinal vein-to-artery diameter ratio and other retinal hypertensive signs are associated with CSFP. Participants of the population-based Beijing Eye Study (n = 1,574 subjects) underwent measurement of the temporal inferior and superior retinal artery and vein diameter. CSFP was calculated as 0.44 × body mass index (kg/m(2)) + 0.16 × diastolic blood pressure (mm Hg) - 0.18 × age (years) - 1.91. Larger retinal vein diameters and higher vein-to-artery diameter ratios were significantly associated with higher estimated CSFP (P = 0.001) in multivariable analysis. In contrast, temporal inferior retinal arterial diameter was marginally associated (P = 0.03) with estimated CSFP, and temporal superior artery diameter was not significantly associated (P = 0.10) with estimated CSFP; other microvascular abnormalities, such as arteriovenous crossing signs, were also not significantly associated with estimated CSFP. In a reverse manner, higher estimated CSFP as a dependent variable in the multivariable analysis was associated with wider retinal veins and higher vein-to-artery diameter ratio. In the same model, estimated CSFP was not significantly correlated with retinal artery diameters or other retinal microvascular abnormalities. Correspondingly, arterial hypertension was associated with retinal microvascular abnormalities such as arteriovenous crossing signs (P = 0.003), thinner temporal retinal arteries (P < 0.001), higher CSFP (P < 0.001), and wider retinal veins (P = 0.001) or, as a corollary, with a higher vein-to-artery diameter ratio in multivariable analysis. Wider retinal vein diameters are associated with higher estimated CSFP and vice versa. In arterial hypertension, an increased retinal vein-to-artery diameter ratio depends on elevated CSFP, which is correlated with blood pressure. © American Journal of Hypertension, Ltd 2014. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. The in vivo blood compatibility of bio-inspired small diameter vascular graft: effect of submicron longitudinally aligned topography

    PubMed Central

    2013-01-01

    Background Cardiovascular disease is the leading cause of deaths worldwide and the arterial reconstructive surgery remains the treatment of choice. Although large diameter vascular grafts have been widely used in clinical practices, there is an urgent need to develop a small diameter vascular graft with enhanced blood compatibility. Herein, we fabricated a small diameter vascular graft with submicron longitudinally aligned topography, which mimicked the tunica intima of the native arterial vessels and were tested in Sprague–Dawley (SD) rats. Methods Vascular grafts with aligned and smooth topography were prepared by electrospinning and were connected to the abdominal aorta of the SD rats to evaluate their blood compatibility. Graft patency and platelet adhesion were evaluated by color Doppler ultrasound and immunofluorescence respectively. Results We observed a significant higher patency rate (p = 0.021) and less thrombus formation in vascular graft with aligned topography than vascular graft with smooth topography. However, no significant difference between the adhesion rates on both vascular grafts (smooth/aligned: 0.35‰/0.12‰, p > 0.05) was observed. Moreover, both vascular grafts had few adherent activated platelets on the luminal surface. Conclusion Bionic vascular graft showed enhanced blood compatibility due to the effect of surface topography. Therefore, it has considerable potential for using in clinical application. PMID:24083888

  13. Hypoxic pulmonary vasoconstriction in isolated mouse pulmonary arterial vessels.

    PubMed

    Strielkov, Ievgen; Krause, Nicole Catherine; Sommer, Natasha; Schermuly, Ralph Theo; Ghofrani, Hossein Ardeschir; Grimminger, Friedrich; Gudermann, Thomas; Dietrich, Alexander; Weissmann, Norbert

    2018-06-19

    What is the central question of this study? Hypoxic pulmonary vasoconstriction has never been characterized in isolated mouse pulmonary arteries of different generations in detail. What is the main finding and its importance? We found that only small intrapulmonary arteries (80 - 200 μm in diameter) exhibit hypoxic pulmonary vasoconstriction. The observed response was sustained, significantly potentiated by depolarization-induced preconstriction, and not dependent on endothelium and TRPC6 channels. Hypoxic pulmonary vasoconstriction (HPV) is a physiological response of pulmonary arteries, which adapts lung perfusion to regional ventilation. Properties of hypoxic pulmonary vasoconstriction (HPV) vary significantly between animal species. Despite extensive use of mouse models in studies of HPV, this physiological response has never been characterized in isolated mouse pulmonary arteries in detail. We investigated the effect of 80-min exposure to hypoxia on tone in mouse pulmonary arteries of different generations in the presence and absence of preconstriction using wire myography. Hypoxia induced a sustained relaxation in non-preconstricted extrapulmonary arteries (500 - 700 μm in diameter), but not in the presence of KCl-induced preconstriction. Large intrapulmonary arteries (450 - 650 μm) did not exhibit a significant response to the hypoxic challenge. By contrast, in small intrapulmonary arteries (80 - 200 μm), hypoxia elicited a slowly developing sustained constriction, which was independent of endothelium. The response was significantly potentiated in arteries preconstricted with KCl, but not with U46619. HPV was not altered in pulmonary arteries of TRPC6-deficient mice, which suggests that this response corresponds to the sustained phase of biphasic HPV observed earlier in isolated, buffer-perfused, and ventilated mouse lungs. In conclusion, we have established the protocol allowing to study sustained HPV in isolated mouse pulmonary arteries. The obtained data may be useful for future studies of HPV mechanisms in mice. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  14. [Rotation angioplasty of chronic coronary artery stenosis].

    PubMed

    Kaltenbach, M; Vallbracht, C

    1990-10-01

    Coronary artery occlusion of more than six months duration can only rarely be recanalized with conventional techniques. For this reason, rotational angioplasty, which has been successfully applied for occlusion of peripheral arteries, has been employed in modified form for recanalization of chronic coronary artery occlusion. Rotational angioplasty is based on the concept that the slowly revolving, dull and relatively thick head of the flexible rotation catheter will seek the path of least resistance which, even in the case of relatively old arterial occlusions, mostly represents thrombotic material. The elastic, high-torque rotational catheter constructed of several V2A spiral steel wires has an interior lumen for insertion of exchange guidewires up to 0.014" and injection of contrast medium and an olive-shaped head of V2A steel with a diameter of 1.3 to 1.6 mm. A protection catheter made of polyethylene with metal markers and conically-tapered tip provides variable stiffness of the rotating catheter and protection of the endothelium in the proximal vascular segment. The slow rotation of 200 r.p.m. is performed with a small electric motor. Between April 1987 and February 1988, rotation angioplasty was performed in 20 patients, 17 with occlusion of the right coronary artery, two with occlusion of the left anterior descending artery and one with bypass graft occlusion to the left anterior descending artery in whom a conventional guidewire through the chronic occlusion could not be advanced. The duration of occlusion, based on previous angiograms anginal complaints or myocardial infarction, ranged from one month to twelve years, in twelve patients more than six months. In all patients, the indication for revascularization was clearly established.(ABSTRACT TRUNCATED AT 250 WORDS)

  15. Incidence and predictors of radial artery spasm during transradial coronary angiography and intervention.

    PubMed

    Jia, De-An; Zhou, Yu-Jie; Shi, Dong-Mei; Liu, Yu-Yang; Wang, Jian-Long; Liu, Xiao-Li; Wang, Zhi-Jian; Yang, Shi-Wei; Ge, Hai-Long; Hu, Bin; Yan, Zhen-Xian; Chen, Yi; Gao, Fei

    2010-04-05

    Radial artery spasm (RAS) is the most common complication in transradial coronary angiography and intervention. In this study, we designed to investigate the incidence of RAS during transradial procedures in Chinese, find out the independent predictors through multiple regression, and analyze the clinical effect of RAS during follow-up. Patients arranged to receive transradial coronary angiography and intervention were consecutively enrolled. The incidence of RAS was recorded. Univariate analysis was performed to find out the influence factors of RAS, and logistic regression analysis was performed to find out the independent predictors of RAS. The patients were asked to return 1 month later for the assessment of the radial access. The incidence of RAS was 7.8% (112/1427) in all the patients received transradial procedure. Univariate analysis indicates that young (P = 0.038), female (P = 0.026), small diameter of radial artery (P < 0.001), diabetes (P = 0.026), smoking (P = 0.019), moderate or severe pain during radial artery cannulation (P < 0.001), unsuccessful access at first attempt (P = 0.002), big sheath (P = 0.004), number of catheters (> 3) (P = 0.048), rapid baseline heart rate (P = 0.032) and long operation time (P = 0.021) were associated with RAS. Logistic regression showed that female (OR = 1.745, 95%CI: 1.148 - 3.846, P = 0.024), small radial artery diameter (OR = 4.028, 95%CI: 1.264 - 12.196, P = 0.008), diabetes (OR = 2.148, 95%CI: 1.579 - 7.458, P = 0.019) and unsuccessful access at first attempt (OR = 1.468, 95%CI: 1.212 - 2.591, P = 0.032) were independent predictors of RAS. Follow-up at (28 +/- 7) days after the procedure showed that, compared with non-spasm patients, the RAS patients had higher portion of pain (11.8% vs. 6.2%, P = 0.043). The occurrences of hematoma (7.3% vs. 5.6%, P = 0.518) and radial artery occlusion (3.6% vs. 2.6%, P = 0.534) were similar. The incidence of RAS during transradial coronary procedure was 7.8%. Logistic regression analysis showed that female, small radial artery diameter, diabetes and unsuccessful access at first attempt were the independent predictors of RAS.

  16. A simple on-line arterial time-activity curve detector for [O-15] water PET studies

    NASA Astrophysics Data System (ADS)

    Wollenweber, S. D.; Hichwa, R. D.; Ponto, L. L. B.

    1997-08-01

    A simple, automated on-line detector system has been fabricated and implemented to detect the arterial time-activity curve (TAG) for bolus-injection [O-15] water PET studies. This system offers two significant improvements over existing systems: a pump mechanism is not required to control arterial blood flow through the detector and dispersion correction of the time-activity curve for dispersion in external tubing is unnecessary. The [O-15] positrons emanating from blood within a thin-walled, 0.134 cm inner-diameter plastic tube are detected by a 0.5 cm wide by 1.0 cm long by 0.1 cm thick plastic scintillator mounted to a miniature PMT. Photon background is reduced to insignificant levels by a 2.0 cm thick cylindrical lead shield. Mean cerebral blood flow (mCBF) determined from an autoradiographic model and from the TAC measured by 1-second automated sampling was compared to that calculated from a TAC acquired using 5-second integrated manual samples. Improvements in timing resolution (1-sec vs. 5-sec) cause small but significant differences between the two sampling methods. Dispersion is minimized due to small tubing diameters, short lengths of tubing between the radial arterial sampling site and the detector and the presence of a 3-way valve 10 cm proximal to the detector.

  17. Vascular corrosion casting of normal and pre-eclamptic placentas.

    PubMed

    Yin, Geping; Chen, Ming; Li, Juan; Zhao, Xiaoli; Yang, Shujun; Li, Xiuyun; Yuan, Zheng; Wu, Aifang

    2017-12-01

    Pre-eclampsia is an important cause of maternal and fetal morbidity and mortality that is associated with decreased placental perfusion. In the present study, vascular corrosion casting was used to investigate the differences in structural changes of the fetoplacental vasculature between normal and pre-eclamptic placentas. An improved epoxy resin vascular casting technique was used in the present study. Casting media were infused into 40 normal and 40 pre-eclamptic placentas through umbilical arteries and veins in order to construct three dimensional fetoplacental vasculatures. The number of branches, diameter, morphology and peripheral artery-to-vein ratio were measured for each specimen. The results indicated that the venous system of normal placentas was divided into 5-7 grades of branches and the volume of the vascular bed was 155.5±45.3 ml. In severe pre-eclamptic placentas, the volume was 106.4±36.1 ml, which was significantly lower compared with normal placentas (P<0.01). The venous system of pre-eclamptic placentas was divided into 4-5 grades of branches, which was much more sparse compared with normal placentas. In additions, the diameters of grade 1-3 veins and grade 2-3 arteries were significantly smaller in severe pre-eclampsia (P<0.05). In conclusion, pre-eclamptic placentas displayed a decreased volume of vascular bed, smaller diameters of grade 1-3 veins and grade 2-3 arteries, and an increased peripheral artery-to-vein ratio, which may be a cause of the placental dysfunction during severe pre-eclampsia.

  18. Does the type of renal artery anatomic variant determine the diameter of the main vessel supplying a kidney? A study based on CT data with a particular focus on the presence of multiple renal arteries.

    PubMed

    Majos, Marcin; Stefańczyk, Ludomir; Szemraj-Rogucka, Zofia; Elgalal, Marcin; De Caro, Raffaele; Macchi, Veronica; Polguj, Michał

    2018-04-01

    An in-depth knowledge of renal vascular anatomy is essential when planning many surgical procedures; however, a few data exists regarding renal artery diameter. The aim of this study was to assess this morphological feature and to investigate whether a correlation exists between renal artery diameter and the type of arterial supply, with a particular emphasis on variant anatomy and the presence of multiple renal arteries. Computed tomography angiography (CTA) studies of 248 patients, i.e., a total of 496 kidneys, were evaluated. The mean age of the patients was 66.4 ± 15.01 years. Renal artery diameter was measured based on the type of arterial blood supply. The frequency of occurrence of three anatomic variants of renal arterial supply was established: single renal artery (RA) 43.35%, single artery with prehilar branching (pRA) 37.30%, and multiple renal artery (mRA) 19.35%. The diameter of single renal arteries, with either prehilar or hilar branching, was significantly larger than when multiple arteries were present. A detailed analysis of just the mRA variant demonstrated that the diameter of the renal arteries in men was larger (p = 0.012) than those in women and that there was no difference in diameter with regard to the side of the body (p = 0.219). The classification described in our study containing a detailed description of renal artery diameter. It may be helpful in clinical practice, especially for transplantologists, surgeons, and vascular surgeons.

  19. Simulation and assessment of cerebrovascular damage in deep brain stimulation using a stereotactic atlas of vasculature and structure derived from multiple 3- and 7-tesla scans.

    PubMed

    Nowinski, Wieslaw L; Chua, Beng Choon; Volkau, Ihar; Puspitasari, Fiftarina; Marchenko, Yevgen; Runge, Val M; Knopp, Michael V

    2010-12-01

    The most severe complication of deep brain stimulation (DBS) is intracranial hemorrhage. Detailed knowledge of the cerebrovasculature could reduce the rate of this disorder. Morphological scans typically acquired in stereotactic and functional neurosurgery (SFN) by using 1.5-T (or sometimes even 3-T) imaging units poorly depict the vasculature. Advanced angiographic imaging, including 3- and 7-T 3D time-of-flight and susceptibility weighted imaging as well as 320-slice CT angiography, depict the vessels in great detail. However, these acquisitions are not used in SFN clinical practice, and robust methods for their processing are not available yet. Therefore, the authors proposed the use of a detailed 3D stereotactic cerebrovascular atlas to assist in SFN planning and to potentially reduce DBS-induced hemorrhage. A very detailed 3D cerebrovascular atlas of arteries, veins, and dural sinuses was constructed from multiple 3- and 7-T scans. The atlas contained>900 vessels, each labeled with a name and diameter with the smallest having a 90-μm diameter. The cortical areas, ventricular system, and subcortical structures were fully segmented and labeled, including the main stereotactic target structures: subthalamic nucleus, ventral intermediate nucleus of the thalamus, and internal globus pallidus. The authors also developed a computer simulator with the embedded atlas that was able to compute the effective electrode trajectory by minimizing penetration of the cerebrovascular system and vital brain structures by a DBS electrode. The simulator provides the neurosurgeon with functions for atlas manipulation, target selection, trajectory planning and editing, 3D display and manipulation, and electrode-brain penetration calculation. This simulation demonstrated that a DBS electrode inserted in the middle frontal gyrus may intersect several arteries and veins including 1) the anteromedial frontal artery of the anterior cerebral artery as well as the prefrontal artery and the precentral sulcus artery of the middle cerebral artery (range of diameters 0.4-0.6 mm); and 2) the prefrontal, anterior caudate, and medullary veins (range of diameters 0.1-2.3 mm). This work also shows that field strength and pulse sequence have a substantial impact on vessel depiction. The numbers of 3D vascular segments are 215, 363, and 907 for 1.5-, 3-, and 7-T scans, respectively. Inserting devices into the brain during microrecording and stimulation may cause microbleeds not discernible on standard scans. A small change in the location of the DBS electrode can result in a major change for the patient. The described simulation increases the neurosurgeon's awareness of this phenomenon. The simulator enables the neurosurgeon to analyze the spatial relationships between the track and the cerebrovasculature, ventricles, subcortical structures, and cortical areas, which allows the DBS electrode to be placed more effectively, and thus potentially reducing the invasiveness of the stimulation procedure for the patient.

  20. Anatomical study of the popliteal artery perforator-based propeller flap and its clinical application.

    PubMed

    Onishi, Tadanobu; Shimizu, Takamasa; Omokawa, Shohei; Sananpanich, Kanit; Kido, Akira; Mahakkanukrauh, Pasuk; Tanaka, Yasuhito

    2018-05-30

    There is lack of anatomical information regarding cutaneous perforator of the popliteal artery and its connections with the descending branch of the inferior gluteal and profunda femoris arteries. We aimed to evaluate the anatomical basis of popliteal artery perforator-based propeller flap from the posterior thigh region and to demonstrate our experience utilizing this flap. Ten fresh cadaveric lower extremities were dissected following injection of a silicone compound into the femoral artery. We investigated the number, location, length, and diameter of cutaneous perforators of the popliteal artery. Based on the results, we treated three cases with a large soft tissue defect around the knee using popliteal artery perforator-based propeller flap. We found a mean of 1.9 cutaneous perforators arising from the popliteal artery with a mean pedicle length of 6 cm and a mean arterial internal diameter of 0.9 mm, which were located at an average of 4 cm proximal to the bicondylar line. The most distal perforator consistently arose along the small saphenous vein and connected proximally with concomitant artery of the posterior femoral cutaneous nerve, forming a connection with perforating arteries of the profunda femoris artery. A mean of 4.5 cutaneous perforators branched from the arterial connection sites. All clinical cases healed without any complications. The popliteal artery perforator-based propeller flap is reliable for reconstruction of soft tissue defects around the knee. The flap should include the deep fascia and concomitant artery along with the posterior femoral cutaneous nerve for maintaining the blood supply.

  1. The vascularization of a gastric tube as a substitute for the esophagus is affected by its diameter.

    PubMed

    Pierie, J P; de Graaf, P W; van Vroonhoven, T J; Obertop, H

    1998-10-01

    The stomach is used for reconstruction of the upper gastrointestinal tract after esophageal resection for cancer. The whole stomach can be used, but also a wide or narrow gastric tube can be constructed. Short-term functional results are superior after use of a narrow tube. Healing of the cervical esophagogastrostomy can be impaired, leading to leakage and stricture. The decreased vascularization at the site of the anastomosis may be one reason. It was hypothesized that the quality of the vascularization of the gastric tube, used as a substitute for the oesophagus after esophagectomy, depends on its diameter. The vascularization of postmortem specimens was studied using angiography. Whole stomachs (3), wide (3) and narrow gastric tubes (3) were constructed. In a patient with an anastomotic stricture of a narrow tube with a cervical esophagogastrostomy vascularisation was evaluated by angiography. After infusion of contrast through the supplying arteries, the whole stomachs and wide gastric tubes showed adequate vascularization, whereas the narrow gastric tube showed poor vascularization especially at the site of the anastomosis. In narrow gastric tubes, the right gastroepiploic artery was the only feeding artery. In the patient's angiography, a limited contrast visualization of the proximal end of the gastric tube could be demonstrated. Although a narrow gastric tube is favoured by some surgeons, the use of whole stomach or a type of gastric tube with preservation of the right gastric artery may lead to a better anastomotic healing.

  2. An animal model for instructing and the study of in situ arterial bypass.

    PubMed

    Saifi, J; Chang, B B; Paty, P S; Kaufman, J; Leather, R P; Shah, D M

    1990-11-01

    A canine model that used the cephalic vein to bypass from the brachial to the ulnar artery was designed for use in instructing and evaluating surgical technique needed for constructing an in situ arterial bypass. This model was used for instructing vascular residents in the in situ vein bypass technique. The use of this model enabled the resident to become more adept with the instruments for valve incision and construction of small vessel anastomosis. The improvement in the resident's operative technique was reflected by a decrease in the number of technical complications (missed valves, missed arteriovenous fistulas, poorly constructed anastomoses) and improved patency rate.

  3. Computational modeling of HHH therapy and impact of blood pressure and hematocrit.

    PubMed

    Robinson, Joe Sam; Walid, M Sami; Hyun, Sinjae; O'Connell, Robert; Menard, Chris; Bohleber, Brandi

    2010-01-01

    After an aneurysmal subarachnoid hemorrhage, cerebral microcirculatory changes occur as a result cerebral vasospasm. The objective of this study is to investigate, with a computational model, how various degrees of vasospasm are influenced by increasing the mean blood pressure and decreasing the blood viscosity. Using ANSYS CFX software, a computational model was constructed to simulate steady-state fully developed laminar blood flow through a rigid wall system consisting of the internal carotid artery (ICA), anterior cerebral artery, posterior cerebral artery, and middle cerebral artery (MCA). The MCA was selected for the site of a single acute vasospasm. Five severities of vasospasm were studied: 3 mm (normal), 2.5, 2, 1.5, and 1 mm. The ICA was assumed to have a constant inlet flow rate of 315 mL/min. The anterior cerebral artery and posterior cerebral artery were assumed to have constant outlet flow rates of 105 mL/min and 30 mL/min, respectively. The MCA was assumed to have a constant outlet pressure of 92 mL/min. Two different hematocrits, 45% and 32%, were simulated using the models. For a hematocrit of 45, the mean ICA inlet pressure required to pump blood through the system was 104 mm Hg for the 3-mm diameter MCA and 105, 108, 116, and 158 mm Hg for vasospasm diameters of 2.5, 2, 1.5, and 1 mm, respectively. For a hematocrit of 32, the mean ICA inlet pressure required was 102, 103, 105, 113, and 152 mm Hg, respectively. The MCA required a large increase in mean ICA inlet pressure for vasospasm diameters less than 1.5 mm, which suggests that for vasospasms more than 50% diameter reduction, the blood pressure must be increased dramatically. Decreasing the hematocrit had minimal impact on blood flow in a constricted vessel. Copyright © 2010 Elsevier Inc. All rights reserved.

  4. A prosthesis for banding the main pulmonary artery, capable of serial dilatation by balloon angioplasty.

    PubMed

    Vince, D J; Culham, J A

    1989-03-01

    A prosthesis constructed with a fatigued steel helix encased in a silicone rubber shield was used to band the main pulmonary artery in 10 dogs. After a mean duration of 138 days the banded site was dilated with a 20 mm diameter angioplasty catheter. This dilatation produced a mean increase of 44.3% in the cross-sectional area. A further mean increase of 2.2% in the cross-sectional area was measured 137 days after the dilatation. In five uncomplicated experiments a second dilatation was performed with a 23 mm diameter angioplasty catheter after a mean interval of 140 days. The second dilatation produced a further 21% increase in the cross-sectional area. In the five experiments in which two dilatations were performed, there was a total increase in the mean cross-sectional area of 94% produced 273 days after banding. This prosthesis maintains banding of the main pulmonary artery and can be serially dilated by balloon angioplasty.

  5. The relationship of flow velocities to vessel diameters differs between extracranial carotid and vertebral arteries of stroke patients.

    PubMed

    Owolabi, Mayowa O; Agunloye, Atinuke M; Ogunniyi, Adesola

    2014-01-01

    Chronic changes in flow rate through arteries produce adjustment of arterial diameters. We compared the relationship between flow velocity and diameter in the carotid and in the vertebral arteries of stroke patients. Using triplex ultrasonography, the internal diameter and flow velocities of the common carotid, internal carotid, and vertebral arteries of 176 consecutive stroke patients were measured. Correlations were examined with Pearson's statistics at an alpha level of 0.05. Mean age of the patients was 59.3 ± 12 years, and 66% had cerebral infarcts. Diameter and blood flow velocities showed significant negative correlations (-0.115 ≥ r ≥ -0.382) in the carotid arteries on both sides, but positive correlations (0.211 ≤ r ≤ 0.320) in the vertebral arteries, even after controlling for age, gender, and blood pressure. Our study demonstrated different diameter/flow relationships in the carotid and the vertebral arteries of stroke patients, which may suggest pathologic changes in the adaptive processes governing vessel diameter and growth, especially in the carotid arteries. Copyright © 2013 Wiley Periodicals, Inc.

  6. Small diameter symmetric networks from linear groups

    NASA Technical Reports Server (NTRS)

    Campbell, Lowell; Carlsson, Gunnar E.; Dinneen, Michael J.; Faber, Vance; Fellows, Michael R.; Langston, Michael A.; Moore, James W.; Multihaupt, Andrew P.; Sexton, Harlan B.

    1992-01-01

    In this note is reported a collection of constructions of symmetric networks that provide the largest known values for the number of nodes that can be placed in a network of a given degree and diameter. Some of the constructions are in the range of current potential engineering significance. The constructions are Cayley graphs of linear groups obtained by experimental computation.

  7. CT Evaluation of Small-Diameter Coronary Artery Stents: Effect of an Integrated Circuit Detector with Iterative Reconstruction.

    PubMed

    Geyer, Lucas L; Glenn, G Russell; De Cecco, Carlo Nicola; Van Horn, Mark; Canstein, Christian; Silverman, Justin R; Krazinski, Aleksander W; Kemper, Jenny M; Bucher, Andreas; Ebersberger, Ullrich; Costello, Philip; Bamberg, Fabian; Schoepf, U Joseph

    2015-09-01

    To use suitable objective methods of analysis to assess the influence of the combination of an integrated-circuit computed tomographic (CT) detector and iterative reconstruction (IR) algorithms on the visualization of small (≤3-mm) coronary artery stents. By using a moving heart phantom, 18 data sets obtained from three coronary artery stents with small diameters were investigated. A second-generation dual-source CT system equipped with an integrated-circuit detector was used. Images were reconstructed with filtered back-projection (FBP) and IR at a section thickness of 0.75 mm (FBP75 and IR75, respectively) and IR at a section thickness of 0.50 mm (IR50). Multirow intensity profiles in Hounsfield units were modeled by using a sum-of-Gaussians fit to analyze in-plane image characteristics. Out-of-plane image characteristics were analyzed with z upslope of multicolumn intensity profiles in Hounsfield units. Statistical analysis was conducted with one-way analysis of variance and the Student t test. Independent of stent diameter and heart rate, IR75 resulted in significantly increased xy sharpness, signal-to-noise ratio, and contrast-to-noise ratio, as well as decreased blurring and noise compared with FBP75 (eg, 2.25-mm stent, 0 beats per minute; xy sharpness, 278.2 vs 252.3; signal-to-noise ratio, 46.6 vs 33.5; contrast-to-noise ratio, 26.0 vs 16.8; blurring, 1.4 vs 1.5; noise, 15.4 vs 21.2; all P < .001). In the z direction, the upslopes were substantially higher in the IR50 reconstructions (2.25-mm stent: IR50, 94.0; IR75, 53.1; and FBP75, 48.1; P < .001). The implementation of an integrated-circuit CT detector provides substantially sharper out-of-plane resolution of coronary artery stents at 0.5-mm section thickness, while the use of iterative image reconstruction mostly improves in-plane stent visualization.

  8. Comparative morphometric analysis of 5 interpositional arterial autograft options for adult living donor liver transplantation.

    PubMed

    Imakuma, E S; Bordini, A L; Millan, L S; Massarollo, P C B; Caldini, E T E G

    2014-01-01

    In living donor liver transplantation, the right-sided graft presents thin and short vessels, bringing forward a more difficult anastomosis. In these cases, an interpositional arterial autograft can be used to favor the performance of the arterial anastomosis, making the procedure easier and avoiding surgical complications. We compared the inferior mesenteric artery (IMA), the splenic artery (SA), the inferior epigastric artery (IEA), the descending branch of the lateral circumflex femoral artery (LCFA), and the proper hepatic artery (PHA) as options for interpositional autograft in living donor liver transplantation. Segments of at least 3 cm of all 5 arteries were harvested from 16 fresh adult cadavers from both genders through standardized dissection. The analyzed measures were proximal and distal diameter and length. The proximal diameter of the RHA and the distal diameter of the SA, IMA, IEA and the LCFA were compared to the distal diameter of the RHA. The proximal and distal diameters of the SA, IEA and LCFA were compared to study caliber gain of each artery. All arteries except the IMA showed statistical significant difference in relation to the RHA in terms of diameter. Regarding caliber gain, the arteries demonstrated statistical significant difference. All the harvested arteries except PHA were 3 cm in length. The IMA demonstrated the best compatibility with the RHA in terms of diameter and showed sufficient length to be employed as interpositional graft. The PHA, the SA, the IEA and the LCFA presented statistically significant different diameters when compared to the RHA. Among these vessels, only the PHA did not show sufficient mean length. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Normative growth data for the external diameters of the external and internal iliac arteries in human fetuses--an anatomical, digital and statistical study.

    PubMed

    Szpinda, Michał; Szpinda, Anna

    2012-01-01

    Normative data on the diameters of the aorto-iliac segment are extremely useful in the diagnosis and monitoring of prenatal arterial variants and pathologies. The present study describes age-specific reference intervals and normal growth curves for the external diameters of the external and internal iliac arteries. Using anatomical dissection and digital-image analysis, the normal growth of the external diameters of the external and internal iliac arteries was studied in 124 spontaneously aborted human fetuses, aged 15-34 weeks. Neither sex differences nor laterality differences were found. The external diameters of the external iliac arteries increased from 0.31 +/- 0.06 to 1.41 +/- 0.31 mm on the right, and from 0.29 +/- 0.04 to 1.37 +/- 0.24 mm on the left, and generated the following growth curves of best fit: y = 0.665 - 0.056 x Age + 0.002 x Age2 +/- 0.143 (R2 = 0.82) and y = 0.612 - 0.052 x Age + 0.002 x Age2 +/- 0.118 (R2 = 0.86), respectively. The external diameters of the internal iliac arteries were found to be statistically larger than those of the external iliac arteries (p = 0.0000). The external diameters of the internal iliac arteries ranged from 0.44 +/- 0.07 to 2.04 +/- 0.43 mm on the right, and from 0.44 +/- 0.06 to 1.83 +/- 0.43 mm on the left, and modeled the following quadratic functions: y = 1.524 - 0.127 x Age + 0.004 x Age2 +/- 0.242 (R2 = 0.74), and y = 1.391 - 0.117 x Age + 0.004 x Age2 +/- 0.220 (R2 = 0.76), respectively. The right external iliac arteries (in 71% of the cases) and the right internal iliac arteries (in 65.3% of cases) were larger in external diameter. The values of the external diameters of the external and internal iliac arteries are independent of sex. A strong trend towards higher values for the right external and internal iliac arteries is noted. The external diameter of the internal iliac artery is nearly 1.5 times greater than that of the external iliac artery. Surprisingly, normal growth of the external diameters of the external and internal iliac arteries follows quadratic functions.

  10. Renal Artery Embolization Combined With Radiofrequency Ablation in a Porcine Kidney Model: Effect of Small and Narrowly Calibrated Microparticles as Embolization Material on Coagulation Diameter, Volume, and Shape

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sommer, C. M., E-mail: christof.sommer@med.uni-heidelberg.de; Kortes, N.; Zelzer, S.

    2011-02-15

    The purpose of this study was to evaluate the effect of renal artery embolization with small and narrowly calibrated microparticles on the coagulation diameter, volume, and shape of radiofrequency ablations (RFAs) in porcine kidneys. Forty-eight RFAs were performed in 24 kidneys of 12 pigs. In 6 animals, bilateral renal artery embolization was performed with small and narrowly calibrated microparticles. Upper and lower kidney poles were ablated with identical system parameters. Applying three-dimensional segmentation software, RFAs were segmented on registered 2 mm-thin macroscopic slices. Length, depth, width, volume{sub s}egmented, and volume{sub c}alculated were determined to describe the size of the RFAs.more » To evaluate the shape of the RFAs, depth-to-width ratio (perfect symmetry-to-lesion length was indicated by a ratio of 1), sphericity ratio (perfect sphere was indicated by a sphericity ratio of 1), eccentricity (perfect sphere was indicated by an eccentricity of 0), and circularity (perfect circle was indicated by a circularity of 1) were determined. Embolized compared with nonembolized RFAs showed significantly greater depth (23.4 {+-} 3.6 vs. 17.2 {+-} 1.8 mm; p < 0.001) and width (20.1 {+-} 2.9 vs. 12.6 {+-} 3.7 mm; p < 0.001); significantly larger volume{sub s}egmented (8.6 {+-} 3.2 vs. 3.0 {+-} 0.7 ml; p < 0.001) and volume{sub c}alculated (8.4 {+-} 3.0 ml vs. 3.3 {+-} 1.1 ml; p < 0.001); significantly lower depth-to-width (1.17 {+-} 0.10 vs. 1.48 {+-} 0.44; p < 0.05), sphericity (1.55 {+-} 0.44 vs. 1.96 {+-} 0.43; p < 0.01), and eccentricity (0.84 {+-} 0.61 vs. 1.73 {+-} 0.91; p < 0.01) ratios; and significantly greater circularity (0.62 {+-} 0.14 vs. 0.45 {+-} 0.16; p < 0.01). Renal artery embolization with small and narrowly calibrated microparticles affected the coagulation diameter, volume, and shape of RFAs in porcine kidneys. Embolized RFAs were significantly larger and more spherical compared with nonembolized RFAs.« less

  11. Numerical investigation of fluid-particle interactions for embolic stroke

    NASA Astrophysics Data System (ADS)

    Mukherjee, Debanjan; Padilla, Jose; Shadden, Shawn C.

    2016-04-01

    Roughly one-third of all strokes are caused by an embolus traveling to a cerebral artery and blocking blood flow in the brain. The objective of this study is to gain a detailed understanding of the dynamics of embolic particles within arteries. Patient computed tomography image is used to construct a three-dimensional model of the carotid bifurcation. An idealized carotid bifurcation model of same vessel diameters was also constructed for comparison. Blood flow velocities and embolic particle trajectories are resolved using a coupled Euler-Lagrange approach. Blood is modeled as a Newtonian fluid, discretized using the finite volume method, with physiologically appropriate inflow and outflow boundary conditions. The embolus trajectory is modeled using Lagrangian particle equations accounting for embolus interaction with blood as well as vessel wall. Both one- and two-way fluid-particle coupling are considered, the latter being implemented using momentum sources augmented to the discretized flow equations. It was observed that for small-to-moderate particle sizes (relative to vessel diameters), the estimated particle distribution ratio—with and without the inclusion of two-way fluid-particle momentum exchange—were found to be similar. The maximum observed differences in distribution ratio with and without the coupling were found to be higher for the idealized bifurcation model. Additionally, the distribution was found to be reasonably matching the volumetric flow distribution for the idealized model, while a notable deviation from volumetric flow was observed in the anatomical model. It was also observed from an analysis of particle path lines that particle interaction with helical flow, characteristic of anatomical vasculature models, could play a prominent role in transport of embolic particle. The results indicate therefore that flow helicity could be an important hemodynamic indicator for analysis of embolus particle transport. Additionally, in the presence of helical flow, and vessel curvature, inclusion of two-way momentum exchange was found to have a secondary effect for transporting small to moderate embolus particles—and one-way coupling could be used as a reasonable approximation, thereby causing substantial savings in computational resources.

  12. The validity of arterial measurements in a South African embalmed body population.

    PubMed

    Schoeman, Marelize; van Schoor, Albert; Suleman, Farhana; Louw, Liebie; du Toit, Peet

    2018-01-01

    Knowledge of the normal arterial diameter at a given anatomical point is the first step toward quantifying the severity of cardiovascular diseases. According to several studies, parameters such as weight, height, age and sex can explain morphometric variations in arterial anatomy that are observed in a population. Before the development of a reference database against which to compare the diameters of arteries in a variety of pathological conditions, the compatibility between embalmed body measurements and computed tomography (CT) measurements must first be established. The aim of this study was to compare embalmed body measurements and CT measurements at 19 different arterial sites to establish whether embalmed body measurements are a true reflection of a living population. A total of 154 embalmed bodies were randomly selected from the Department of Anatomy at the University of Pretoria and 36 embalmed bodies were randomly selected from the Department of Human Anatomy at the University of Limpopo, Medunsa Campus. Dissections were performed on the embalmed body sample and the arterial dimensions were measured with a mechanical dial-sliding caliper (accuracy of 0.01 mm). 30 CT images for each of the 19 arterial sites were retrospectively selected from the database of radiographic images at the Department of Radiology, Steve Biko Academic Hospital. Radiant, a Digital Imaging and Communications in Medicine (DICOM) viewer was used to analyze the CT images. The only statistically significant differences between the embalmed body measurements and CT measurements were found in the left common carotid- and the left subclavian arteries. The null hypothesis of no statistically significant difference between the embalmed body and CT measurements was accepted since the P value indicated no significant difference for 87% of the measurements, the exception being the left common carotid- and the left subclavian arteries. With the exception of two measurements, measurements in embalmed bodies and living people are interchangeable and concerns regarding the effect of distortion and shrinkage are unfounded. Even small changes in arterial diameter greatly influence blood flow and blood pressure, which contribute to undesirable clinical outcomes such as aortic aneurysms and aortic dissections. This study completes the first step towards the development of a reference database against which to compare the diameters of arteries in a variety of pathological conditions in a South African population.

  13. Neurogenic regulation of cochlear blood flow occurs along the basilar artery, the anterior inferior cerebellar artery and at branch points of the spiral modiolar artery.

    PubMed

    Wangemann, Philine; Wonneberger, Kai

    2005-11-01

    The cochlea receives its main blood supply from the basilar artery via the anterior inferior cerebellar artery and the spiral modiolar artery. Morphologic studies have shown sympathetic innervation along the spiral modiolar artery of the gerbil and the guinea pig and functional studies in the isolated in vitro superfused spiral modiolar artery of the gerbil have demonstrated norepinephrine-induced vasoconstrictions via alpha(1A)-adrenergic receptors. It is current unclear whether the sympathetic innervation is physiologically relevant. Stimulation of sympathetic ganglia in guinea pigs has been shown to alter cochlear blood flow in situ. Whether these changes originated from local or more systemic changes in the vascular diameter remained uncertain. The goal of the present study was to demonstrate the presence or absence of neurogenic changes in the diameter of the isolated in vitro superfused spiral modiolar artery, anterior inferior cerebellar artery and basilar artery from the gerbil and the guinea pig. Vascular diameter was monitored by videomicroscopy. Electric field stimulation was used to elicit neurotransmitter release. A reversible inhibitory effect of 10(-6) M tetrodotoxin was taken as criterion to discriminate between neurogenic and myogenic changes in vascular diameter. Mesentery arteries of comparable diameter, which are known to respond with a neurogenic vasoconstriction to electric field stimulation, served as controls. Basilar artery, anterior inferior cerebellar artery, spiral modiolar artery and mesentery arteries constricted in response to electric field stimulation. No dilations were observed. Myogenic and neurogenic vasoconstrictions were observed in all vessels. These observations suggest that the sympathetic innervation of the basilar artery, the anterior inferior cerebellar artery and branch points of the spiral modiolar artery is involved in a physiologically relevant control of the vascular diameter in the gerbil and the guinea pig.

  14. Engineering poly(hydroxy butyrate-co-hydroxy valerate) based vascular scaffolds to mimic native artery.

    PubMed

    Deepthi, S; Nivedhitha Sundaram, M; Vijayan, Ponni; Nair, Shantikumar V; Jayakumar, R

    2018-04-01

    Electrospun tri-layered fibrous scaffold incorporating VEGF and Platelet Factor Concentrate (PFC) in multiple layers having different layer architectures was designed to mimic native artery. The scaffold consisted of longitudinally aligned poly(hydroxy butyrate-co-hydroxy valerate) (PHBV) and poly(vinyl alcohol) (PVA) nanofibers (inner layer), radially aligned PHBV-elastin nanofibers (middle layer) to provide the bi-directional alignment and combination of longitudinally aligned PHBV-elastin and random PHBV/PVA multiscale fibers (peripheral layer). Tubular constructs of diameter <6 mm were developed. The developed electrospun fibers were characterised by Scanning Electron Microscope (SEM), Fourier Transform Infrared Spectroscopy and Tensile tests. Further the burst strength, compliance and stiffness index of tri-layered tubular scaffold was evaluated. SEM images of fibrous layers showed the typical longitudinal and radial alignment of fibers in the tubular construct. SEM images showed that the prepared PHBV nanofibers were in the range of 500-800 nm and PHBV microfibers were of 1-2 μm in diameter in the tri-layered electrospun membrane. PVA nanofibers were of size 200-250 nm. The tensile strength, percentage compliance and stiffness index of tri-layered membrane was in accordance with that of native small blood vessels. The developed tri-layered membrane was blood compatible, with hemolysis degree 0.85 ± 0.21% and did not activate platelets. Controlled release of VEGF and PFC was observed from the scaffold. The biocompatibility of the tri-layered scaffold was evaluated using HUVECs, SMCs and MSCs and SMCs infiltration from the outer layer was also evaluated. Specific protein expression for the HUVECs and SMCs was evaluated by flow cytometry and immunocytochemistry. HUVECs and SMCs exhibited good elongation and alignment along the direction of fibers and was found to maintain its CD31, VE-Cadherin and αSMA expression respectively. The results highlight the importance of bi-directional fiber alignment on the tri-layered electrospun scaffold as a suitable architectural prototype for vascular scaffolds to mimic the native arteries. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Hypertrophic remodeling of subcutaneous small resistance arteries in patients with Cushing's syndrome.

    PubMed

    Rizzoni, Damiano; Porteri, Enzo; De Ciuceis, Carolina; Rodella, Luigi F; Paiardi, Silvia; Rizzardi, Nicola; Platto, Caterina; Boari, Gianluca E M; Pilu, Annamaria; Tiberio, Guido A M; Giulini, Stefano M; Favero, Gaia; Rezzani, Rita; Rosei, Claudia Agabiti; Bulgari, Giuseppe; Avanzi, Daniele; Rosei, Enrico Agabiti

    2009-12-01

    Structural alterations of small resistance arteries in essential hypertensive patients (EH) are mostly characterized by inward eutrophic remodeling. However, we observed hypertrophic remodeling in patients with renovascular hypertension, in those with acromegaly, as well as in patients with non-insulin-dependent diabetes mellitus, suggesting a relevant effect of humoral growth factors on vascular structure, even independent from the hemodynamic load. Cortisol may stimulate the renin-angiotensin system and may induce cardiac hypertrophy. However, presently no data are available about small artery structure in patients with Cushing's syndrome. We have investigated the structure of sc small resistance arteries in 12 normotensive subjects (NT), in 12 EH subjects, and in eight patients with Cushing's syndrome (CS). Small arteries from sc fat were dissected and mounted on a micromyograph. The normalized internal diameter, media thickness, media to lumen ratio, and the media cross-sectional area were measured, as well as indices of oxidative stress. Demographic variables were similar in the three groups, except for clinic blood pressure. The media to lumen ratio was significantly greater in EH and CS, compared with NT; no difference was observed between EH and CS. The media cross-sectional area was significantly greater in CS compared with EH and with NT. An increased vascular oxidative stress was present in CS, as demonstrated by increased levels of superoxide anions, cyclooxygenase-1 and endothelial nitric oxide synthase in the microvessels. Our results suggest the presence of hypertrophic remodeling in sc small resistance arteries of CS, probably as a consequence of growth-promoting properties of circulating cortisol and/or increased vascular oxidative stress.

  16. A NEW PRINCIPLE FOR ELECTROMAGNETIC CATHETER FLOW METERS*

    PubMed Central

    Kolin, Alexander

    1969-01-01

    An electromagnetic catheter flow meter is described in which the magnetic field is generated by two parallel bundles of wire carrying equal currents in opposite directions. The electrodes are fixed centrally to the insulated wire bundles that generate the magnetic field. The flow sensor is flexible, resembling a split catheter. The flow transducer is designed to constrict as it is introduced through a branch artery and to expand in the main artery over the span of its diameter. The principle is suitable for branch flow measurement as well as for measurement of flow in a major artery or vein by the same transducer. A special method of guiding the electrode wires results in a zero base line at zero flow for the entire range of diameters accommodating the field generating coil. The electrodes could be used in this configuration with a magnetic field generated by coils external to the patient for blood flow measurements with a catheter of reduced gauge. The transducer can be made smaller in circumference than those employed in other electromagnetic flow measuring catheter devices. This feature is of special value for envisaged clinical uses (percutaneous introduction) to minimize surgical intervention. The velocity sensitivity of the flow transducer is a logarithmic function of the tube diameter. The flow throughout the entire tube cross section contributes to the flow signal. It is sufficient to calibrate the transducer by one measurement in a dielectric conduit of less than maximum diameter. The sensitivity at other diameters follows from a logarithmic plot. The diameter of the blood vessel is outlined by the transducer in radiograms, thus obviating the need for radiopaque materials. The principle was demonstrated by measurements in vitro. Experiments in vivo, derivation of equations, and construction details will be published elsewhere. Images PMID:5257127

  17. Early and late outcome of skeletonised bilateral internal mammary arteries anastomosed to the left coronary system.

    PubMed

    Bonacchi, M; Battaglia, F; Prifti, E; Leacche, M; Nathan, N S; Sani, G; Popoff, G

    2005-02-01

    To investigate in a retrospective study the technical aspects of using the in situ bilateral internal mammary arteries (IMAs), with the right IMA (RIMA) used for revascularisation of the circumflex system, and to evaluate early and late outcome. Between January 1997 and July 2003, 552 consecutive patients underwent grafting of the circumflex artery system with an in situ skeletonised RIMA routed through the transverse sinus (eventually retrocaval). Mean (SD) age was 63.8 (11) years. 331 (60%) patients underwent total arterial myocardial revascularisation. Mean follow up was 26 (9) months. The success rate of skeletonised RIMA grafting to the circumflex branch was 100%. There were 19 (3.4%) in-hospital deaths. Perioperative myocardial infarction occurred in 12 (2.2%) patients. In 155 patients undergoing postoperative angiography, two had an occluded RIMA and a string-like phenomenon was seen in three RIMA and one left IMA (LIMA). Three RIMA and three LIMA had stenotic lesions. The patency rates of RIMA and LIMA were 94% and 97.4%, respectively. Strong predictors of non-functional IMA grafts were a recipient coronary artery diameter of < 1.5 mm (p = 0.022), < 60% stenosis of the recipient coronary artery (p = 0.015), diffuse stenotic lesions of the recipient coronary artery (p = 0.018), and a small IMA calibre (p = 0.0001). Cumulative actuarial survival at three years was 96.4% and event-free cumulative survival was 93.8%. Use of the bilateral IMAs offers the possibility of constructing various configurations, making total arterial myocardial revascularisation possible with a minimum number of arterial conduits. Use of the skeletonised RIMA through the transverse sinus and eventually retrocavally can reach most branches of the circumflex system and is associated with an excellent patency rate. Patients who received bilateral IMA grafts for left coronary system revascularisation had improved early and late outcomes and decreased risk of death, reoperation, and angioplasty.

  18. Morphological Analysis of Bronchial Arteries and Variants with Computed Tomography Angiography.

    PubMed

    Esparza-Hernández, Claudia Nallely; Ramírez-González, Juan Manuel; Cuéllar-Lozano, Rolando Alberto; Morales-Avalos, Rodolfo; González-Arocha, Carla Sofía; Martínez-González, Brenda; Quiroga-Garza, Alejandro; Pinales-Razo, Ricardo; Elizondo-Riojas, Guillermo; Elizondo-Omaña, Rodrigo Enrique; Guzmán-López, Santos

    2017-01-01

    The aim of our study was to determine the prevalence of anatomical variants of bronchial arteries using computed tomographic angiography in a population of northeastern Mexico. An observational, transversal, descriptive, comparative, retrospective study was performed using 139 imaging studies of Mexican patients in which we evaluated the following parameters from the left and right bronchial arteries: artery origin, branching pattern, arterial ostium, vertebral level of origin, diameter, and mediastinal trajectory. The anatomies of the bronchial arteries were similar in both genders, except distribution for vertebral origin level ( p   0.006) and the diameter ( p   0.013). Left and right arteries were similar, except for the mediastinal trajectory in reference to the esophagus ( p < 0.001) as well as the arterial diameter ( p < 0.001) and lumen diameter.

  19. Arterial pressure transfer characteristics: effects of travel time.

    PubMed

    Westerhof, Berend E; Guelen, Ilja; Stok, Wim J; Wesseling, Karel H; Spaan, Jos A E; Westerhof, Nico; Bos, Willem Jan; Stergiopulos, Nikos

    2007-02-01

    We investigated the quantitative contribution of all local conduit arterial, blood, and distal load properties to the pressure transfer function from brachial artery to aorta. The model was based on anatomical data, Young's modulus, wall viscosity, blood viscosity, and blood density. A three-element windkessel represented the distal arterial tree. Sensitivity analysis was performed in terms of frequency and magnitude of the peak of the transfer function and in terms of systolic, diastolic, and pulse pressure in the aorta. The root mean square error (RMSE) described the accuracy in wave-shape prediction. The percent change of these variables for a 25% alteration of each of the model parameters was calculated. Vessel length and diameter are found to be the most important parameters determining pressure transfer. Systolic and diastolic pressure changed <3% and RMSE <1.8 mmHg for a 25% change in vessel length and diameter. To investigate how arterial tapering influences the pressure transfer, a single uniform lossless tube was modeled. This simplification introduced only small errors in systolic and diastolic pressures (1% and 0%, respectively), and wave shape was less well described (RMSE, approximately 2.1 mmHg). Local (arm) vasodilation affects the transfer function little, because it has limited effect on the reflection coefficient. Since vessel length and diameter translate into travel time, this parameter can describe the transfer accurately. We suggest that with a, preferably, noninvasively measured travel time, an accurate individualized description of pressure transfer can be obtained.

  20. Spatial resonance in a small artery excited by vibration input as a possible mechanism to cause hand-arm vascular disorders

    NASA Astrophysics Data System (ADS)

    Pattnaik, Shrikant; Banerjee, Rupak; Kim, Jay

    2012-04-01

    Hand-arm vibration syndrome (HAVS) is collectively a vasospastic and neurodegenerative occupational disease. One of the major symptoms of HAVS is vibration white finger (VWF) caused by exaggerated vasoconstriction of the arteries and skin arterioles. While VWF is a very painful and costly occupational illness, its pathology has not been well understood. In this study a small artery is modeled as a fluid filled elastic tube whose diameter changes along the axial direction. Equations of motion are developed by considering interactions between the fluid, artery wall and soft-tissue bed. It is shown that the resulting wave equation is the same as that of the basilar membrane in the cochlea of mammals. Therefore, the artery system shows a spatial resonance as in the basilar membrane, which responds with the highest amplitude at the location determined by the vibration frequency. This implies that a long-term use of one type of tool will induce high-level stresses at a few identical locations of the artery that correspond to the major frequency components of the tool. Hardening and deterioration of the artery at these locations may be a possible cause of VWF.

  1. Aortic outflow occlusion predicts rupture of abdominal aortic aneurysm.

    PubMed

    Crawford, Jeffrey D; Chivukula, Venkat Keshav; Haller, Stephen; Vatankhah, Nasibeh; Bohannan, Colin J; Moneta, Gregory L; Rugonyi, Sandra; Azarbal, Amir F

    2016-12-01

    Current threshold recommendations for elective abdominal aortic aneurysm (AAA) repair are based solely on maximal AAA diameter. Peak wall stress (PWS) has been demonstrated to be a better predictor than AAA diameter of AAA rupture risk. However, PWS calculations are time-intensive, not widely available, and therefore not yet clinically practical. In addition, PWS analysis does not account for variations in wall strength between patients. We therefore sought to identify surrogate clinical markers of increased PWS and decreased aortic wall strength to better predict AAA rupture risk. Patients treated at our institution from 2001 to 2014 for ruptured AAA (rAAA) were retrospectively identified and grouped into patients with small rAAA (maximum diameter <6 cm) or large rAAA (>6 cm). Patients with large (>6 cm) non-rAAA were also identified sequentially from 2009 for comparison. Demographics, vascular risk factors, maximal aortic diameter, and aortic outflow occlusion (AOO) were recorded. AOO was defined as complete occlusion of the common, internal, or external iliac artery. Computational fluid dynamics and finite element analysis simulations were performed to calculate wall stress distributions and to extract PWS. We identified 61 patients with rAAA, of which 15 ruptured with AAA diameter <60 mm (small rAAA group). Patients with small rAAAs were more likely to have peripheral arterial disease (PAD) and chronic obstructive pulmonary disease (COPD) than were patients in the large non-rAAA group. Patients with small rAAAs were also more likely to have AOO compared with non-rAAAs >60 mm (27% vs 8%; P = .047). Among all patients with rAAAs, those with AOO ruptured at smaller mean AAA diameters than in patients without AOO (62.1 ± 11.8 mm vs 72.5 ± 16.4 mm; P = .024). PWS calculations of a representative small rAAA and a large non-rAAA showed a substantial increase in PWS with AOO. We demonstrate that AOO, PAD, and COPD in AAA are associated with rAAAs at smaller diameters. AOO appears to increase PWS, whereas COPD and PAD may be surrogate markers of decreased aortic wall strength. We therefore recommend consideration of early, elective AAA repair in patients with AOO, PAD, or COPD to minimize risk of early rupture. Copyright © 2016. Published by Elsevier Inc.

  2. Effects of gravitational stress, hypokinesia and hypodynamia on the structure of the vascular bed of the spleen

    NASA Technical Reports Server (NTRS)

    Nesterenko, N. T.

    1980-01-01

    The effects of two extreme factors, hypokinesia and hypodynamia, on spleen vascular beds were studied on 180 male and female albino rats. Vessels were studied by roentgenography, microroentgenography, clearing of sections and histology. Gravity stress yielded construction of all links of arterial bed and of order 5-7 veins. Large intraorganic vein diameters changed significantly but erratically. Hypokinesia in early phases produced pronounced spleen size reduction. Veins and arteries constricted along entire length. Later hypokinetic stages showed arteries still constricted; veins began to dilate from week 4 of hypokinesia. Sinuosity, uneven contours and varicose dilations of walls in large arteries and veins occurred. Abrupt changes in parenchyma, e.g., atrophy of folliculi, narrowing of lumen of central arteries from thickening of muscular wall. After exposure to hypokinesia followed by gravitational stress, pronounced lesions such as deformation of vascular wall, including rupture, in all vessels of the spleen vascular bed.

  3. Forearm arterial anatomy and flow characteristics: a prospective observational study.

    PubMed

    Pancholy, Samir B; Heck, Laura A; Patel, Tejas

    2015-04-01

    Morphometric data on Caucasian radial and ulnar arteries are limited, with no data on flow interdependence in the forearm arterial circuit. A total of 250 upper extremities in 125 patients were evaluated. Ultrasonography was performed and radial and ulnar artery lumen diameters were measured. Ulnar artery (UA) was compressed at the level of the wrist, and flow parameters in radial artery (RA) were recorded using duplex Doppler ultrasound. Radial and ulnar artery diameters were comparable at the level of the distal forearm (RA = 2.03 ± 0.28 mm, UA = 2.07 ± 0.27 mm; P=.14). There was no significant difference in radial or ulnar artery diameter between the dominant upper extremity and the non-dominant upper extremity. Upon compression of the ulnar artery, radial artery velocity-time integral (VTI) increased from 8.4 ± 3.8 cm to 12.8 ± 5.5 cm, which was statistically significant (P<.001). There was a significant inverse correlation between radial artery diameter and the magnitude of increase in radial VTI observed with UA compression (r² = 0.106; P<.001). RA diameter at the level of the distal forearm is comparable to UA. RA-VTI and likely flow significantly increase by compression of the UA. The smaller the radial artery, the larger the increase in radial artery flow with ulnar compression.

  4. Positron autoradiography for intravascular imaging: feasibility evaluation

    NASA Astrophysics Data System (ADS)

    Shikhaliev, Polad M.; Xu, Tong; Ducote, Justin L.; Easwaramoorthy, Balasubramaniam; Mukherjee, Jogeshwar; Molloi, Sabee

    2006-02-01

    Approximately 70% of acute coronary artery disease is caused by unstable (vulnerable) plaques with an inflammation of the overlying cap and high lipid content. A rupturing of the inflamed cap of the plaque results in propagation of the thrombus into the lumen, blockage of the artery and acute ischaemic syndrome or sudden death. Morphological imaging such as angiography or intravascular ultrasound cannot determine inflammation status of the plaque. A radiotracer such as 18F-FDG is accumulated in vulnerable plaques due to higher metabolic activity of the inflamed cap and could be used to detect a vulnerable plaque. However, positron emission tomography (PET) cannot detect the FDG-labelled plaques because of respiratory and heart motions, small size and low activity of the plaques. Plaques can be detected using a miniature particle (positron) detector inserted into the artery. In this work, a new detector concept is investigated for intravascular imaging of the plaques. The detector consists of a storage phosphor tip bound to the end of an intravascular catheter. It can be inserted into an artery, absorb the 18F-FDG positrons from the plaques, withdrawn from the artery and read out. Length and diameter of the storage phosphor tip can be matched to the length and the diameter of the artery. Monte Carlo simulations and experimental evaluations of coronary plaque imaging with the proposed detector were performed. It was shown that the sensitivity of the storage phosphor detector to the positrons of 18F-FDG is sufficient to detect coronary plaques with 1 mm and 2 mm sizes and 590 Bq and 1180 Bq activities in the arteries with 2 mm and 3 mm diameters, respectively. An experimental study was performed using plastic tubes with 2 mm diameter filled with an FDG solution, which simulates blood. FDG spots simulating plaques were placed over the surface of the tube. A phosphor tip was inserted into the tube and imaged the plaques. Exposure time was 1 min in all simulations and experiments. Experiments showed that detecting the coronary plaques using the proposed technique is possible. The proposed technique has the potential for fast and accurate detection of vulnerable coronary and other intravascular plaques.

  5. Second-Trimester 3-Dimensional Placental Sonography as a Predictor of Small-for-Gestational-Age Birth Weight.

    PubMed

    Quant, Hayley S; Sammel, Mary D; Parry, Samuel; Schwartz, Nadav

    2016-08-01

    We previously reported the association between first-trimester 3-dimensional (3D) placental measurements and small-for-gestational-age (SGA) neonates. In this study, we sought to determine whether second-trimester measurements further contribute to the antenatal detection of SGA and preeclampsia. We prospectively collected 3D sonographic volume sets and uterine artery pulsatility indices of singleton pregnancies at 18 to 24 weeks. Placental volume, placental quotient (placental volume/gestational age), mean placental diameter and chorionic diameter, placental morphologic index (mean placental diameter/placental quotient), placental chorionic index (mean chorionic diameter/placental quotient), and placental growth (volume per week) were assessed and evaluated as predictors of SGA and preeclampsia as a composite and alone. Of 373 pregnancies, the composite outcome occurred in 67 (18.0%): 36 (9.7%) manifested SGA alone; 27 (7.2%) developed preeclampsia alone, and 4 (1.1%) developed both. The placental volume, placental quotient, mean placental diameter, mean chorionic diameter, and volume per week were significantly smaller, whereas the placental morphologic index and chorionic index were significantly larger in pregnancies with the composite outcome (P < .01). Further analyses revealed that the significant associations with placental parameters were limited to the SGA outcome. Each placental measure remained significantly associated with SGA after adjusting for confounders. The mean uterine artery pulsatility index was not associated with either outcome. Placental parameters were moderately predictive of SGA, with adjusted areas under the curve ranging from 0.72 to 0.76. Sensitivity for detection of SGA ranged from 32.5% to 45.0%, with positive predictive values ranging from 17.3% to 22.7%. Second-trimester 3D placental measurements can identify pregnancies at risk of SGA. However, there appears to be no significant improvement compared to those obtained in the first trimester.

  6. Common iliac artery aneurysms in patients with abdominal aortic aneurysms.

    PubMed

    Armon, M P; Wenham, P W; Whitaker, S C; Gregson, R H; Hopkinson, B R

    1998-03-01

    To determine the incidence of common iliac artery (CIA) aneurysms in patients with abdominal aortic aneurysms (AAA) and to evaluate the relationship between AAA and CIA diameter. Spiral CT angiography was used to measure the maximum diameters of the abdominal aorta and the common iliac arteries of 215 patients with AAA. The median CIA diameter was 1.7 cm--significantly greater than the published mean of 1.25 (2 S.D. = 0.85-1.65) cm of an age-matched, non-vascular population. Thirty-four patients (16%) had unilateral and 26 patients (12%) bilateral CIA aneurysms > or = 2.4 cm diameter. Eight-six vessels (20%) were affected. Right CIA diameters were wider than left CIA diameters (p < 0.0001, Wilcoxon matched-pairs signed rank test). The correlation between AAA size and CIA diameter was weak. The AAA population has abnormally dilated common iliac arteries. In this population, common iliac artery aneurysms should be defined as those greater than 2.4 cm diameter. 20% of CIAs in patients with AAA are aneurysmal according to this definition.

  7. Antishear Stress Bionic Carbon Nanotube Mesh Coating with Intracellular Controlled Drug Delivery Constructing Small-Diameter Tissue-Engineered Vascular Grafts.

    PubMed

    Ding, Ning; Dou, Ce; Wang, Yuxin; Liu, Feila; Guan, Ge; Huo, Da; Li, Yanzhao; Yang, Jingyuan; Wei, Keyu; Yang, Mingcan; Tan, Ju; Zeng, Wen; Zhu, Chuhong

    2018-06-01

    Small-diameter (<6 mm) tissue-engineered blood vessels (TEBVs) have a low patency rate due to chronic inflammation mediated intimal hyperplasia. Functional coating with drug release is a promising solution, but preventing the released drug from being rushed away by blood flow remains a great challenge. A single-walled carboxylic acid functionalized carbon nanotube (C-SWCNT) is used to build an irregular mesh for TEBV coating. However, an interaction between the released drug and the cells is still insufficient due to the blood flow. Thus, an intracellular drug delivery system mediated by macrophage cellular uptake is designed. Resveratrol (RSV) modified CNT is used for macrophage uptake. M1 macrophage uptakes CNT-RSV and then converts to the M2 phenotype upon intracellular RSV release. Prohealing M2 macrophage inhibits the chronic inflammation thus maintains the contractile phenotype of the vascular smooth muscle cell (VSMC), which reduces intimal hyperplasia. Additionally, RSV released from the mesh coating also directly protects the contractile VSMCs from being converted to a secretory phenotype. Through antishear stress coating and macrophage-based intracellular drug delivery, CNT-RSV TEBVs exhibit a long-term anti-intimal hyperplasia function. Animal transplantation studies show that the patency rate remains high until day 90 after grafting in rat carotid arteries. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Obesity and overweight associated with increased carotid diameter and decreased arterial function in young otherwise healthy men.

    PubMed

    Kappus, Rebecca M; Fahs, Christopher A; Smith, Denise; Horn, Gavin P; Agiovlasitis, Stomatis; Rossow, Lindy; Jae, Sae Y; Heffernan, Kevin S; Fernhall, Bo

    2014-04-01

    Obesity is linked to cardiovascular disease, stroke, increased mortality and vascular remodeling. Although increased arterial diameter is associated with multiple cardiovascular risk factors and obesity, it is unknown whether lumen enlargement is accompanied by unfavorable vascular changes in young and otherwise healthy obese individuals. The purpose of this study was to compare carotid and brachial artery diameter, blood pressure, arterial stiffness, and endothelial function in young, apparently healthy, normal-weight, overweight, and obese male subjects. One hundred sixty-five male subjects (27.39±0.59 years) were divided into 3 groups (normal weight, overweight, and obese) according to body mass index. Subjects underwent cardiovascular measurements to determine arterial diameter, function, and stiffness. After adjusting for age, the obese group had significantly greater brachial, carotid, and aortic pressures, brachial pulse wave velocity, carotid intima media thickness, and carotid arterial diameter compared with both the overweight and normal-weight groups. Obesity is associated with a much worse arterial profile, as an increased carotid lumen size was accompanied by higher blood pressure, greater arterial stiffness, and greater carotid intima media thickness in obese compared with overweight or normal-weight individuals. These data suggest that although obesity may be a factor in arterial remodeling, such remodeling is also accompanied by other hemodynamic and arterial changes consistent with reduced arterial function and increased cardiovascular risk.

  9. Obesity and Overweight Associated With Increased Carotid Diameter and Decreased Arterial Function in Young Otherwise Healthy Men

    PubMed Central

    2014-01-01

    BACKGROUND Obesity is linked to cardiovascular disease, stroke, increased mortality and vascular remodeling. Although increased arterial diameter is associated with multiple cardiovascular risk factors and obesity, it is unknown whether lumen enlargement is accompanied by unfavorable vascular changes in young and otherwise healthy obese individuals. The purpose of this study was to compare carotid and brachial artery diameter, blood pressure, arterial stiffness, and endothelial function in young, apparently healthy, normal-weight, overweight, and obese male subjects. METHODS One hundred sixty-five male subjects (27.39±0.59 years) were divided into 3 groups (normal weight, overweight, and obese) according to body mass index. Subjects underwent cardiovascular measurements to determine arterial diameter, function, and stiffness. RESULTS After adjusting for age, the obese group had significantly greater brachial, carotid, and aortic pressures, brachial pulse wave velocity, carotid intima media thickness, and carotid arterial diameter compared with both the overweight and normal-weight groups. CONCLUSIONS Obesity is associated with a much worse arterial profile, as an increased carotid lumen size was accompanied by higher blood pressure, greater arterial stiffness, and greater carotid intima media thickness in obese compared with overweight or normal-weight individuals. These data suggest that although obesity may be a factor in arterial remodeling, such remodeling is also accompanied by other hemodynamic and arterial changes consistent with reduced arterial function and increased cardiovascular risk. PMID:24048148

  10. [Transcatheter embolization for huge pulmonary arteriovenous fistula using metallic "spider" and spring embolus--application of hand-made metallic "spider" using partial monorail technique].

    PubMed

    Hirota, S; Sako, M; Fujita, Y; Hasegawa, Y; Sugimoto, K; Suzuki, Y; Kono, M

    1992-07-25

    We performed transcatheter embolization in two cases with huge pulmonary arteriovenous fistula (AVF) using a metallic "spider" and spring embolus. Conventional spring embolus or detachable balloon could not be used in these cases. Metallic spider was indicated for pulmonary AVF with a feeding artery diameter of more than 16 mm to prevent embolus passing through the AVF. In the first case, we used large handmade metallic spiders of 25 mm in diameter followed by embolization by numerous spring coils. At that time, a partial monorail technique was newly devised to carry the large metallic spider into the feeding artery, otherwise the spider could not pass into a 9F catheter. After embolization, symptoms and PaO2 in arterial blood improved remarkably in both cases. In the second case, a spring coil migrated into the normal pulmonary artery, but no infarction resulted. In conclusion, the metallic spider was very useful for embolization of hugee pulmonary AVF to avoid the embolus passing through and to tangle spring coils together with it. If commercially available "spiders" are too small, ones can be made easily.

  11. Common Carotid Artery Diameter and Risk of Cardiovascular Events and Mortality: Pooled Analyses of Four Cohort Studies.

    PubMed

    Sedaghat, Sanaz; van Sloten, Thomas T; Laurent, Stéphane; London, Gérard M; Pannier, Bruno; Kavousi, Maryam; Mattace-Raso, Francesco; Franco, Oscar H; Boutouyrie, Pierre; Ikram, M Arfan; Stehouwer, Coen D A

    2018-05-21

    Carotid arterial diameter enlargement is a manifestation of arterial remodeling and may be a risk factor for cardiovascular disease (CVD). We evaluated the association between carotid artery diameter and risk of stroke, coronary heart disease, CVD, and all-cause mortality and explored whether the associations could be explained by processes involved in arterial remodeling, that is, blood pressure-related media thickening, arterial stiffness, arterial wall stress, and atherosclerosis. We included 4887 participants (mean age 67±9 years; 54% women) from 4 cohort studies: Rotterdam Study, NEPHROTEST, Hoorn Study, and a study by Blacher et al. Common carotid artery properties were measured using echotracking. Incident cases were recorded based on medical records. We used Cox proportional hazard models adjusting for cardiovascular risk factors and estimates of processes underlying arterial remodeling. During follow-up (mean, 11 years), 379 (8%) individuals had a stroke, 516 had a (11%) coronary heart disease, 807 had a (17%) CVD, and 1486 (30%) had died. After adjustment for cardiovascular risk factors, individuals in the highest tertile of carotid diameter (diameter >8 mm) compared with those in the lowest tertile (diameter <7 mm) had a higher incidence of stroke (hazard ratio, 1.5; 95% confidence interval, 1.1-2.0). From all estimates of processes underlying arterial remodeling, adjustment for carotid intima-media thickness attenuated this association (hazard ratio after adjustment for intima-media thickness, 1.2; 95% confidence interval, 0.9-1.6). Larger carotid diameter was associated with risk of CVD and mortality but not clearly with coronary heart disease risk. We showed that a larger carotid diameter is associated with incident stroke, CVD, and mortality. Carotid intima-media thickness, a measure of blood pressure-related media thickening, partially explained the association with stroke incidence. © 2018 American Heart Association, Inc.

  12. Pharmacologic manipulation of the microcirculation in cutaneous and myocutaneous flaps in pigs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pang, C.Y.; Neligan, P.C.; Nakatsuka, T.

    1985-04-01

    The vascular effects of isoxsuprine, diazoxide, and isoproterenol were studied in arterial buttock flaps and latissimus dorsi myocutaneous flaps in pigs. Capillary blood flow to the skin and muscles of these flaps was measured by the radioactive microsphere (15-mu diameter) technique 6 hours postoperatively under pentobarbital anesthesia. It was observed that isoproterenol, a beta-adrenergic receptor agonist, was not effective in augmentation of skin blood flow in the arterial buttock flaps. However, isoproterenol significantly increased capillary blood flow to the arterialized portion of latissimus dorsi myocutaneous flaps compared with controls. Isoxsuprine and diazoxide (vascular smooth muscle relaxants) significantly (p less thanmore » 0.05) increased total capillary blood flow to the skin of arterial buttock flaps and to the skin and muscles of the latissimus dorsi myocutaneous flaps. However, the increase in capillary blood flow occurred mainly in the arterialized portion of these flaps. The capillary blood flow, which was supplied by the small arteries in the distal portion of the arterial buttock and latissimus dorsi flaps, was not increased by treatment with isoxsuprine or diazoxide. Therefore, there was also no increase in the maximum distance of capillary blood flow from the pedicle to the distal end of the flaps. These observations led the authors to hypothesize that different sizes (diameters) of arteries in the skin and muscle have different reactivity (or sensitivity) to vasodilatory drugs. In the present experiment, the large dominant artery of the arterial buttock and latissimus dorsi flaps responded to isoxsuprine or diazoxide (vascular smooth-muscle relaxants), resulting in an increase in blood supply to the capillaries in the proximal portion of the flaps.« less

  13. Morphometric analysis of small arteries in the human retina using adaptive optics imaging: relationship with blood pressure and focal vascular changes

    PubMed Central

    Koch, Edouard; Rosenbaum, David; Brolly, Aurélie; Sahel, José-Alain; Chaumet-Riffaud, Philippe; Girerd, Xavier; Rossant, Florence; Paques, Michel

    2014-01-01

    Objectives: The wall-to-lumen ratio (WLR) of retinal arteries is a recognized surrogate of end-organ damage due to aging and/or arterial hypertension. However, parietal morphometry remains difficult to assess in vivo. Recently, it was shown that adaptive optics retinal imaging can resolve parietal structures of retinal arterioles in humans in vivo. Here, using adaptive optics retinal imaging, we investigated the variations of parietal thickness of small retinal arteries with blood pressure and focal vascular damage. Methods: Adaptive optics imaging of the superotemporal retinal artery was done in 49 treatment-naive individuals [mean age (±SD) 44.9 years (±14); mean systolic pressure 132 mmHg (±22)]. Semi-automated segmentation allowed extracting parietal thickness and lumen diameter. In a distinct cohort, adaptive optics images of arteriovenous nicking (AVN; n = 12) and focal arteriolar narrowing (FAN; n = 10) were also analyzed qualitatively and quantitatively. Results: In the cohort of treatment-naive individuals, by multiple regression taking into account age, body mass index, mean, systolic, diastolic and pulse blood pressure, the WLR was found positively correlated to mean blood pressure and age which in combination accounted for 43% of the variability of WLR. In the cohort of patients with focal vascular damage, neither FANs or AVNs showed evidence of parietal growth; instead, at sites of FANs, decreased outer diameter suggestive of vasoconstriction was consistently found, while at sites of AVNs venous narrowing could be seen in the absence of arteriovenous contact. Conclusion: High resolution imaging of retinal vessels by adaptive optics allows quantitative microvascular phenotyping, which may contribute to a better understanding and management of hypertensive retinopathy. PMID:24406779

  14. Morphometric analysis of small arteries in the human retina using adaptive optics imaging: relationship with blood pressure and focal vascular changes.

    PubMed

    Koch, Edouard; Rosenbaum, David; Brolly, Aurélie; Sahel, José-Alain; Chaumet-Riffaud, Philippe; Girerd, Xavier; Rossant, Florence; Paques, Michel

    2014-04-01

    The wall-to-lumen ratio (WLR) of retinal arteries is a recognized surrogate of end-organ damage due to aging and/or arterial hypertension. However, parietal morphometry remains difficult to assess in vivo. Recently, it was shown that adaptive optics retinal imaging can resolve parietal structures of retinal arterioles in humans in vivo. Here, using adaptive optics retinal imaging, we investigated the variations of parietal thickness of small retinal arteries with blood pressure and focal vascular damage. Adaptive optics imaging of the superotemporal retinal artery was done in 49 treatment-naive individuals [mean age (±SD) 44.9 years (±14); mean systolic pressure 132  mmHg (±22)]. Semi-automated segmentation allowed extracting parietal thickness and lumen diameter. In a distinct cohort, adaptive optics images of arteriovenous nicking (AVN; n = 12) and focal arteriolar narrowing (FAN; n = 10) were also analyzed qualitatively and quantitatively. In the cohort of treatment-naive individuals, by multiple regression taking into account age, body mass index, mean, systolic, diastolic and pulse blood pressure, the WLR was found positively correlated to mean blood pressure and age which in combination accounted for 43% of the variability of WLR. In the cohort of patients with focal vascular damage, neither FANs or AVNs showed evidence of parietal growth; instead, at sites of FANs, decreased outer diameter suggestive of vasoconstriction was consistently found, while at sites of AVNs venous narrowing could be seen in the absence of arteriovenous contact. High resolution imaging of retinal vessels by adaptive optics allows quantitative microvascular phenotyping, which may contribute to a better understanding and management of hypertensive retinopathy.

  15. Bronchoarterial ratio in never-smokers adults: Implications for bronchial dilation definition.

    PubMed

    Diaz, Alejandro A; Young, Thomas P; Maselli, Diego J; Martinez, Carlos H; Maclean, Erick S; Yen, Andrew; Dass, Chandra; Simpson, Scott A; Lynch, David A; Kinney, Gregory L; Hokanson, John E; Washko, George R; San José Estépar, Raul

    2017-01-01

    Bronchiectasis manifests as recurrent respiratory infections and reduced lung function. Airway dilation, which is measured as the ratio of the diameters of the bronchial lumen (B) and adjacent pulmonary artery (A), is a defining radiological feature of bronchiectasis. A challenge to equating the bronchoarterial (BA) ratio to disease severity is that the diameters of airway and vessel in health are not established. We sought to explore the variability of BA ratio in never-smokers without pulmonary disease and its associations with lung function. Objective measurements of the BA ratio on volumetric computed tomography (CT) scans and pulmonary function data were collected in 106 never-smokers. The BA ratio was measured in the right upper lobe apical bronchus (RB1) and the right lower lobe basal posterior bronchus. The association between the BA ratio and forced expiratory volume in 1 s (FEV 1 ) was assessed using regression analysis. The BA ratio was 0.79 ± 0.16 and was smaller in more peripheral RB1 bronchi (P < 0.0001). The BA ratio was >1, a typical threshold for bronchiectasis, in 10 (8.5%) subjects. Subjects with a BA ratio >1 versus ≤1 had smaller artery diameters (P < 0.0001) but not significantly larger bronchial lumens. After adjusting for age, gender, race and height, the BA ratio was directly related to FEV 1 (P = 0.0007). In never-smokers, the BA ratio varies by airway generation and is associated with lung function. A BA ratio >1 is driven by small arteries. Using artery diameter as reference to define bronchial dilation seems inappropriate. © 2016 Asian Pacific Society of Respirology.

  16. Utility of computed tomography in assessment of pulmonary hypertension secondary to biomass smoke exposure

    PubMed Central

    Sertogullarindan, Bunyamin; Bora, Aydin; Yavuz, Alpaslan; Ekin, Selami; Gunbatar, Hulya; Arisoy, Ahmet; Avcu, Serhat; Ozbay, Bulent

    2014-01-01

    Background The aim of this study was to investigate the feasibility of main pulmonary artery diameter quantification by thoracic computerized tomography (CT) in the diagnosis of pulmonary hypertension seconder to biomass smoke exposure. Material/Methods One hundred and four women subjects with biomass smoke exposure and 20 healthy women subjects were enrolled in the prospective study. The correlation between echocardiographic estimation of systolic pulmonary artery pressure and the main pulmonary artery diameter of the cases were studied. Results The main pulmonary artery diameter was 26.9±5.1 in the control subjects and 37.1±6.4 in subjects with biomass smoke exposure. This difference was statistically significant (p<0.001). The systolic pulmonary artery pressure was 22.7±12.4 in the control subjects and 57.3±22 in subjects with biomass smoke exposure. This difference was statistically significant (p<0.001). Systolic pulmonary artery pressure was significantly correlated with the main pulmonary artery diameter (r=0.614, p<0.01). A receiver operating characteristic (ROC) curve analysis showed that a value of 29 mm of the main pulmonary artery diameter differentiated between pulmonary hypertension and non-pulmonary hypertension patients. The sensitivity of the measurement to diagnose pulmonary hypertension was 91% and specificity was 80%. Conclusions Our results indicate that main pulmonary artery diameter measurements by SCT may suggest presence of pulmonary hypertension in biomass smoke exposed women. PMID:24618994

  17. Longitudinal changes in fetal biometry and cerebroplacental hemodynamics in fetuses with congenital heart disease.

    PubMed

    Ruiz, A; Cruz-Lemini, M; Masoller, N; Sanz-Cortés, M; Ferrer, Q; Ribera, I; Martínez, J M; Crispi, F; Arévalo, S; Gómez, O; Pérez-Hoyos, S; Carreras, E; Gratacós, E; Llurba, E

    2017-03-01

    To determine the longitudinal behavior of fetal biometric measures and cerebroplacental hemodynamics throughout gestation in fetuses with congenital heart disease (CHD). Fetal biometry and Doppler hemodynamics (uterine artery (UtA), umbilical artery (UA) and fetal middle cerebral artery (MCA)) were measured serially in a cohort of consecutive fetuses diagnosed with CHD. Evaluations were made at various time points, from diagnosis (20-25 weeks) to delivery, with at least two measurements per fetus that were at least 2 weeks apart. Fetuses were classified into three groups according to the pattern of blood supply to the brain (placental vs systemic) that would be expected on the basis of the type of CHD. All parameters were transformed into Z-scores. A linear mixed model to analyze repeated measurements was constructed for each parameter to assess its behavior throughout gestation. Four hundred and forty-four ultrasound examinations were performed in 119 CHD fetuses, with a median of two measurements per fetus. The fetuses presented a small head at diagnosis (biparietal diameter (BPD) Z-score, -1.32 ± 0.99; head circumference (HC) Z-score, -0.79 ± 1.02), which remained small throughout gestation. UtA and UA pulsatility indices (PI) showed a significant increase towards the end of pregnancy, whereas no significant changes were observed in MCA-PI or cerebroplacental ratio (CPR) with gestational age. Both MCA and CPR presented significant differences in longitudinal behavior between CHD groups, while BPD and HC did not. CHD fetuses have a relatively small head from the second trimester of pregnancy, regardless of the type of CHD anomaly, and increasing resistance in the UtA and UA as pregnancy progresses, suggestive of increasing degree of placental impairment. Our findings indicate the early onset of mechanisms that could lead to poorer neurodevelopment later in life. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.

  18. PET/CT in giant cell arteritis: High 18F-FDG uptake in the temporal, occipital and vertebral arteries.

    PubMed

    Rehak, Z; Vasina, J; Ptacek, J; Kazda, T; Fojtik, Z; Nemec, P

    18 F-FDG PET/CT imaging is useful in patients with fever of unknown origin and can detect giant cell arteritis in extracranial large arteries. However, it is usually assumed that temporal arteries cannot be visualized with a PET/CT scanner due to their small diameter. Three patients with clinical symptoms of temporal arteritis were examined using a standard whole body PET/CT protocol (skull base - mid thighs) followed by a head PET/CT scan using the brain protocol. High 18 F-FDG uptake in the aorta and some arterial branches were detected in all 3 patients with the whole body protocol. Using the brain protocol, head imaging led to detection of high 18 F-FDG uptake in temporal arteries as well as in their branches (3 patients), in occipital arteries (2 patients) and also in vertebral arteries (3 patients). Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  19. Calculation of the diameter of the central retinal artery from noninvasive measurements in humans.

    PubMed

    Dorner, Guido T; Polska, Elzbieta; Garhöfer, Gerhard; Zawinka, Claudia; Frank, Barbara; Schmetterer, Leopold

    2002-12-01

    The aim of the present study was to calculate the diameter of the central retinal artery from results as obtained with non-invasive techniques in healthy young subjects. Twenty-four healthy male subjects participated in this study. Total retinal blood flow was calculated from combined bi-directional laser Doppler velocimetry and measurement of retinal venous diameters using the Zeiss retinal vessel analyzer. Using these techniques red blood cell velocity and vessel diameters of all visible veins entering the optic nerve head were measured and total retinal blood flow was calculated. Blood flow velocity in the central retinal artery was measured with color Doppler imaging. Form these outcome parameters the diameter of the central retinal artery was calculated for each subject individually. In the present study cohort the mean retinal blood flow was 38.1 +/- 9.1 microl/min and the mean flow velocity in the central retinal artery was 6.3 +/- 1.2 cm/s. From these data we calculated a mean diameter of the central retinal artery of 163 +/- 17 microm. Our results are in good agreement with data obtained from in vitro studies. The data of the present study also indicate that one needs to be careful to interpret velocity data from the central retinal artery in terms of retinal blood flow.

  20. Effects of subcutaneously infiltrated nitroglycerin on diameter, palpability, ease-of-puncture and pre-cannulation spasm of radial artery during transradial coronary angiography.

    PubMed

    Ezhumalai, Babu; Satheesh, Santhosh; Jayaraman, Balachander

    2014-01-01

    The success of transradial catheterization depends on meticulous access of radial artery which in turn depends on palpating a good radial pulse. Our objectives were to analyze the effects of subcutaneously infiltrated nitroglycerin on diameter of radial artery, palpability of radial pulse, ease-of-puncture and pre-cannulation spasm of radial artery during transradial coronary angiography. Patients undergoing transradial coronary angiography were randomized to Group NL or Group SL. In Group NL, 3 ml of solution containing nitroglycerin and lignocaine was infiltrated subcutaneously at the site intended for puncture of radial artery. Similarly, saline and lignocaine were infiltrated in Group SL. Diameter of radial artery was objectively assessed by ultrasonography. Measurements were performed at baseline and repeated at 1 min after injecting the solutions. The ease-of-puncture was evaluated by the number of punctures and the time needed for successful access of radial artery. Both groups had 100 patients each. Baseline diameter of radial artery was similar between two groups. The post-injection diameter of radial artery increased by 26.3% in Group NL and 11.4% in Group SL. Nitroglycerin significantly improved the palpability of radial pulse, reduced the number of punctures and shortened the time needed for successful access of radial artery. Pre-cannulation spasm of radial artery occurred in 1% of Group NL and 8% of Group SL. Subcutaneously infiltrated nitroglycerin leads to significant vasodilation of radial artery. This avoids pre-cannulation spasm of radial artery, enhances palpability of the radial pulse and thus makes the puncture of radial artery easier. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  1. Effects of subcutaneously infiltrated nitroglycerin on diameter, palpability, ease-of-puncture and pre-cannulation spasm of radial artery during transradial coronary angiography

    PubMed Central

    Ezhumalai, Babu; Satheesh, Santhosh; Jayaraman, Balachander

    2014-01-01

    Background The success of transradial catheterization depends on meticulous access of radial artery which in turn depends on palpating a good radial pulse. Objectives Our objectives were to analyze the effects of subcutaneously infiltrated nitroglycerin on diameter of radial artery, palpability of radial pulse, ease-of-puncture and pre-cannulation spasm of radial artery during transradial coronary angiography. Methods Patients undergoing transradial coronary angiography were randomized to Group NL or Group SL. In Group NL, 3 ml of solution containing nitroglycerin and lignocaine was infiltrated subcutaneously at the site intended for puncture of radial artery. Similarly, saline and lignocaine were infiltrated in Group SL. Diameter of radial artery was objectively assessed by ultrasonography. Measurements were performed at baseline and repeated at 1 min after injecting the solutions. The ease-of-puncture was evaluated by the number of punctures and the time needed for successful access of radial artery. Results Both groups had 100 patients each. Baseline diameter of radial artery was similar between two groups. The post-injection diameter of radial artery increased by 26.3% in Group NL and 11.4% in Group SL. Nitroglycerin significantly improved the palpability of radial pulse, reduced the number of punctures and shortened the time needed for successful access of radial artery. Pre-cannulation spasm of radial artery occurred in 1% of Group NL and 8% of Group SL. Conclusions Subcutaneously infiltrated nitroglycerin leads to significant vasodilation of radial artery. This avoids pre-cannulation spasm of radial artery, enhances palpability of the radial pulse and thus makes the puncture of radial artery easier. PMID:25634390

  2. Morphology-related limitations of EVAR applicability in the treatment of AAA in West-Central Poland.

    PubMed

    Dzieciuchowicz, Łukasz; Tomczak, Jolanta; Strauss, Ewa; Oszkinis, Grzegorz

    2018-05-14

    To analyze the current applicability of endovascular aneurysm repair (EVAR) in patients with an infrarenal abdominal aortic aneurysm (AAAs) with indication for elective treatment in West-Central Poland. Computed tomography angiograms of 100 consecutive patients with infrarenal AAA deemed to require treatment were analyzed with an OsiriX DICOM viewer in 3D-MPR mode. Proximal neck diameter, length, angulation, shape, the presence of thrombus and calcification, distal neck diameter, and morphology of the iliac arteries were determined. Three sets of morphological criteria were established. The optimal criteria consisted of a non-conical proximal neck without moderate or severe calcification or thrombus, with a diameter of 18-28 mm, length of ≥15 mm, and β angulation of <60%; a distal neck with a diameter of ≥20 mm; a landing zone in the common iliac arteries with a length of ≥ 10 mm and diameter of ≤ 20 mm; and external iliac arteries with diameters of ≥7 mm. The suboptimal criteria included proximal neck diameters of 18-32 mm, neck lengths ≥10 mm, infrarenal neck angulations of up to 75˚, and common iliac artery diameters of up to 25 mm. Finally, the extended suboptimal criteria included proximal neck diameters of 16-34 mm and infrarenal neck angulations ≤90˚, without limits in the maximal diameter of the common iliac arteries. The median maximum aneurysm diameter was 61 mm. The optimal, suboptimal, and extended suboptimal criteria were met by 23%, 32%, and 53% of patients, respectively. The most common deviations were wide, conical, and angulated proximal necks and aneurysmal iliac arteries. The majority of patients with AAA deemed to be candidates for elective repair do not meet the most favorable criteria for EVAR. Availability of better endovascular solutions for conical, angulated, and wide necks and aneurysmal iliac arteries would likely expand EVAR applicability. Open repair remains a valid option. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Nanofiber alignment of a small diameter elastic electrospun scaffold

    NASA Astrophysics Data System (ADS)

    Patel, Jignesh

    Cardiovascular disease is the leading cause of death in western countries with coronary heart disease making up 50% of these deaths. As a treatment option, tissue engineered grafts have great potential. Elastic scaffolds that mimic arterial extracellular matrix (ECM) may hold the key to creating viable vascular grafts. Electrospinning is a widely used scaffold fabrication technique to engineer tubular scaffolds. In this study, we investigated how the collector rotation speed altered the nanofiber alignment which may improve mechanical characteristics making the scaffold more suitable for arterial grafts. The scaffold was fabricated from a blend of PCL/Elastin. 2D Fast Fourier Transform (FFT) image processing tool and MatLab were used to quantitatively analyze nanofiber orientation at different collector speeds (13500 to 15500 rpm). Both Image J and MatLab showed graphical peaks indicating predominant fiber orientation angles. A collector speed of 15000 rpm was found to produce the best nanofiber alignment with narrow peaks at 90 and 270 degrees, and a relative amplitude of 200. This indicates a narrow distribution of circumferentially aligned nanofibers. Collector speeds below and above 15000 rpm caused a decrease in fiber alignment with a broader orientation distribution. Uniformity of fiber diameter was also measured. Of 600 measures from the 15000 rpm scaffolds, the fiber diameter range from 500 nm to 899 nm was most prevalent. This diameter range was slightly larger than native ECM which ranges from 50 nm to 500 nm. The second most prevalent diameter range had an average of 404 nm which is within the diameter range of collagen. This study concluded that with proper electrospinning technique and collector speed, it is possible to fabricate highly aligned small diameter elastic scaffolds. Image J 2D FFT results confirmed MatLab findings for the analyses of circumferentially aligned nanofibers. In addition, MatLab analyses simplified the FFT orientation data providing an accurate, user friendly orientation measurement tool.

  4. Evaluating physical property changes for small-diameter, plantation-grown southern pine after in situ polymerization of an acrylic monomer

    Treesearch

    Richard Bergman; Rebecca E. Ibach; Constantine LaPasha; Joseph Denig

    2009-01-01

    Because of the large percentage of juvenile wood in small-diameter southern pine, this material has lower strength properties compared with the historic published values in the ASTM Standard D2555. Finding new, simple, and inexpensive ways of increasing these strength properties would increase the use of this material for residential construction. For this study, we...

  5. Protective effects of drag-reducing polymers in a rat model of monocrotaline-induced pulmonary hypertension.

    PubMed

    Wang, Yali; Hu, Feng; Mu, Xiaoyan; Wu, Feng; Yang, Dechun; Zheng, Guixiang; Sun, Xiaoning; Gong, Kaizheng; Zhang, Zhengang

    2016-01-27

    Drag-reducing polymers (DRPs) are blood-soluble macromolecules which may increase blood flow and reduce vascular resistance. The purpose of the present study was to observe the effect of DRPs on monocrotaline-induced pulmonary hypertension (PH) in the rat model. A total of 64 male Wistar rats were randomly divided into four groups: Group I (pulmonary hypertension model + DRP treatment); Group II (pulmonary hypertension model + saline treatment); Group III (control + DRP treatment); Group IV (control + saline treatment). After five weeks, comparisons were made of the following indices: survival rate, body weight, blood pressure, right ventricular systolic pressure, right ventricular hypertrophy, wall thickness of pulmonary arteries, the internal diameter of small pulmonary arteries, plasma IL-1β and IL-6. The survival rate after 5 weeks varied significantly across all groups (P=0.013), but the survival rates of Groups I and II were not statistically significantly different. Administration of DRP (intravenous injection twice weekly) attenuated the PH-induced increase in right ventricular systolic pressure and suppressed the increases in right ventricular (RV) weight and the ratio of right ventricular weight to left ventricle plus septum weight (RV/LV + S). DRP treatment also significantly decreased the wall thickness of pulmonary arteries, augmented the internal diameter of small pulmonary arteries, and suppressed increases in the plasma levels of IL-1β and IL-6. DRP treatment with intravenous injection effectively inhibited the development of monocrotaline-induced pulmonary hypertension in the rat model. DRPs may have potential application for the treatment of pulmonary hypertension.

  6. Methylene blue intra-arterial staining of resected colorectal cancer specimens improves accuracy of nodal staging: A randomized controlled trial.

    PubMed

    Reima, H; Saar, H; Innos, K; Soplepmann, J

    2016-11-01

    Metastatic involvement of regional lymph nodes is a major prognostic factor of colorectal cancer, which influences also its treatment strategy. International consensus foresees retrieval of ≥12 lymph nodes from colorectal specimens. The aim of the study was to assess the effect of intra-arterial staining of colorectal specimens with methylene blue on lymph node harvest. A total of 266 radically operated colorectal cancer patients were randomized into the methylene blue staining and non-staining groups. In the staining group, methylene blue solution was injected into the colorectal specimen's artery after its removal. The specimens were analysed for lymph node count, diameter and metastatic involvement. The median number of lymph nodes was higher in the staining group, 27 (95% CI 23-31%), compared with the control group, 16 (95% CI 14-19, p < 0.001). The number of examined lymph-nodes was ≥12 in 86% of the cases in the staining group and in 69% of the cases in the control group (p = 0.001). In the staining group more small-diameter (≤4 mm) lymph nodes were examined (median number 20.5 vs. 10, p < 0.001). The proportion of patients with metatatic lymph nodes was 42% in the staining group and 43% in the control group (NS). Methylene blue staining improves significantly staging accuracy through finding more small-diameter lymph nodes. It enables to detect ≥12 lymph nodes in the majority of cases. We recommend routine use of this technique in all colorectal resections with curative intent. Copyright © 2016 Elsevier Ltd, BASO ~ the Association for Cancer Surgery, and the European Society of Surgical Oncology. All rights reserved.

  7. Electrospun Polycaprolactone Scaffolds for Small-Diameter Tissue Engineered Blood Vessels

    NASA Astrophysics Data System (ADS)

    Lee, Carol Hsiu-Yueh

    Cardiovascular disease is the leading cause of death in the United States with many patients requiring coronary artery bypass grafting. The current standard is using autografts such as the saphenous vein or intimal mammary artery, however creating a synthetic graft could eliminate this painful and inconvenient procedure. Large diameter grafts have long been established with materials such as DacronRTM and TeflonRTM, however these materials have not proved successful in small-diameter (< 6 mm) grafts where thrombosis and intimal hyperplasia are common in graft failure. With the use of a synthetic biodegradable polymer (polycaprolactone) we utilize our expertise in electrospinning and femtosecond laser ablation to create a novel tri-layered tissue engineered blood vessel containing microchannels. The benefits of creating a tri-layer is to mimic native arteries that contain an endothelium to prevent thrombosis in the inner layer, aligned smooth muscle cells in the middle to control vasodilation and constriction, and a mechanically robust outer layer. The following work evaluates the mechanical properties of such a graft (tensile, fatigue, burst pressure, and suture retention strength), the ability to rapidly align cells in laser ablated microchannels in PCL scaffolds, and the biological integration (co-culture of endothelial and smooth muscle cells) with electrospun PCL scaffolds. The conclusions from this work establish that the electrospun tri-layers provide adequate mechanical strength as a tissue engineered blood vessel, that laser ablated microchannels are able to contain the smooth muscle cells, and that cells are able to adhere to PCL fibers. However, future work includes adjusting microchannel dimensions to properly align smooth muscle cells along with perfect co-cultures of endothelial and smooth muscle cells on the electrospun tri-layer.

  8. Coronary vasodilation by the use of sublingual nitroglycerin using 64-slice dual-source coronary computed tomography angiography.

    PubMed

    Okada, Munemasa; Nakashima, Yoshiteru; Nomura, Takafumi; Miura, Toshiro; Nao, Tomoko; Yoshimura, Masayuki; Sano, Yuichi; Matsunaga, Naofumi

    2015-03-01

    Sublingual nitroglycerin capsules or spray is routinely used to treat anginal attacks and to maximally dilate the epicardial coronary arteries during coronary angiography. These dilated coronary vessels have an advantage, but increased heart rates were disadvantageous for coronary computed tomography angiography (CTA). The influence of applying nitroglycerin was analyzed regarding the coronary diameter, coronary luminal attenuation, evaluable number of coronary segments, heart rate (HR), HR variability, the optimal reconstruction phase, and image scoring of CTA in the same patients using a 64-slice dual-source CT. Fifty-two patients with atypical chest pain underwent coronary CTA before and after the administration of sublingual nitroglycerin without heart rate control. The coronary diameter and luminal attenuation were measured on short-axial images in each coronary segment. The coronary vasodilation ratios (VRs) were calculated from the coronary diameters at the same location before and after the use of nitroglycerin. The local institutional review board approved this study and written informed consent was obtained from all the patients. No significant differences were noted in the HR variability or optimal reconstruction phase, despite an increase in HR after the use of nitroglycerin. Nitroglycerin significantly enlarged the coronary artery diameter, and VRs of each coronary segment ranged from 7.54% to 22.26%. As compared with baseline coronary diameter, VRs of minor segments (16.91%) were significantly larger than those of major segments (11.35%), and the magnitude of VR correlated with the baseline coronary diameter (r=-0.48, p<0.001). Coronary luminal attenuation significantly increased due to additional administration of contrast material after the use of nitroglycerin (p<0.01), but no significant difference was noted in the image quality after the use of nitroglycerin. Sublingual nitroglycerin significantly enlarged the coronary diameters, especially in peripheral small coronary arteries, and increased the evaluable number of coronary segments on coronary CTA. Copyright © 2014 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  9. Aerobic exercise reduces oxidative stress and improves vascular changes of small mesenteric and coronary arteries in hypertension

    PubMed Central

    Roque, Fernanda R; Briones, Ana M; García-Redondo, Ana B; Galán, María; Martínez-Revelles, Sonia; Avendaño, Maria S; Cachofeiro, Victoria; Fernandes, Tiago; Vassallo, Dalton V; Oliveira, Edilamar M; Salaices, Mercedes

    2013-01-01

    Background and Purpose Regular physical activity is an effective non-pharmacological therapy for prevention and control of hypertension. We investigated the effects of aerobic exercise training in vascular remodelling and in the mechanical and functional alterations of coronary and small mesenteric arteries from spontaneously hypertensive rats (SHR). Experimental Approach Normotensive Wistar Kyoto (WKY), SHR and SHR trained on a treadmill for 12 weeks were used to evaluate vascular structural, mechanical and functional properties. Key Results Exercise did not affect lumen diameter, wall thickness and wall/lumen ratio but reduced vascular stiffness of coronary and mesenteric arteries from SHR. Exercise also reduced collagen deposition and normalized altered internal elastic lamina organization and expression of MMP-9 in mesenteric arteries from SHR. Exercise did not affect contractile responses of coronary arteries but improved the endothelium-dependent relaxation in SHR. In mesenteric arteries, training normalized the increased contractile responses induced by U46619 and by high concentrations of acetylcholine. In vessels from SHR, exercise normalized the effects of the NADPH oxidase inhibitor apocynin and the NOS inhibitor l-NAME in vasodilator or vasoconstrictor responses, normalized the increased O2− production and the reduced Cu/Zn superoxide dismutase expression and increased NO production. Conclusions and Implications Exercise training of SHR improves endothelial function and vascular stiffness in coronary and small mesenteric arteries. This might be related to the concomitant decrease of oxidative stress and increase of NO bioavailability. Such effects demonstrate the beneficial effects of exercise on the vascular system and could contribute to a reduction in blood pressure. PMID:22994554

  10. Aerobic exercise reduces oxidative stress and improves vascular changes of small mesenteric and coronary arteries in hypertension.

    PubMed

    Roque, Fernanda R; Briones, Ana M; García-Redondo, Ana B; Galán, María; Martínez-Revelles, Sonia; Avendaño, Maria S; Cachofeiro, Victoria; Fernandes, Tiago; Vassallo, Dalton V; Oliveira, Edilamar M; Salaices, Mercedes

    2013-02-01

    Regular physical activity is an effective non-pharmacological therapy for prevention and control of hypertension. We investigated the effects of aerobic exercise training in vascular remodelling and in the mechanical and functional alterations of coronary and small mesenteric arteries from spontaneously hypertensive rats (SHR). Normotensive Wistar Kyoto (WKY), SHR and SHR trained on a treadmill for 12 weeks were used to evaluate vascular structural, mechanical and functional properties. Exercise did not affect lumen diameter, wall thickness and wall/lumen ratio but reduced vascular stiffness of coronary and mesenteric arteries from SHR. Exercise also reduced collagen deposition and normalized altered internal elastic lamina organization and expression of MMP-9 in mesenteric arteries from SHR. Exercise did not affect contractile responses of coronary arteries but improved the endothelium-dependent relaxation in SHR. In mesenteric arteries, training normalized the increased contractile responses induced by U46619 and by high concentrations of acetylcholine. In vessels from SHR, exercise normalized the effects of the NADPH oxidase inhibitor apocynin and the NOS inhibitor l-NAME in vasodilator or vasoconstrictor responses, normalized the increased O(2) (-) production and the reduced Cu/Zn superoxide dismutase expression and increased NO production. Exercise training of SHR improves endothelial function and vascular stiffness in coronary and small mesenteric arteries. This might be related to the concomitant decrease of oxidative stress and increase of NO bioavailability. Such effects demonstrate the beneficial effects of exercise on the vascular system and could contribute to a reduction in blood pressure. © 2012 The Authors. British Journal of Pharmacology © 2012 The British Pharmacological Society.

  11. Coronary artery dimensions in normal Indians.

    PubMed

    Raut, Barendra Kumar; Patil, Vijaysinh Namdeo; Cherian, George

    Diameter of coronary artery is an important predictor of outcome after percutaneous coronary interventions and coronary artery bypass graft surgery. There is very limited data available about coronary artery dimensions in an Indian population. To study the normal dimensions of the coronary artery segments in Indians without coronary artery disease by using quantitative coronary angiography and also to compare the dimensions in Indians with Western. 229 patients who have undergone coronary angiography with entirely normal coronary angiogram were included in our study. This study showed the diameter of vessels in males and females when taken together the left main was larger in size followed by proximal LAD, proximal RCA & proximal LCX respectively (4.08±0.44mm, 3.27±0.23mm, 3.20±0.37mm, 2.97±0.37mm).When the vessel diameter was indexed to body surface area there was no statistical difference between male and female (p value>0.05). The computed value of proximal coronary artery diameter unadjusted for individual body surface area, when compared to Caucasians showed that Caucasians have larger coronary artery dimensions than Indians. But when the proximal vessel diameter was indexed to body surface area there was no statistical significant difference between Indians and Caucasians (p value>0.05). We found that coronary artery size when indexed to body surface area is not statistically different in Indian males and females and compared to Caucasians. However with a smaller body habitus Indians have smaller coronary arteries. Copyright © 2017. Published by Elsevier B.V.

  12. Anatomical and technical tips for use of the superficial inferior epigastric artery (SIEA) flap in breast reconstructive surgery.

    PubMed

    Dorafshar, Amir H; Januszyk, Michael; Song, David H

    2010-08-01

    Techniques for autologous breast reconstruction have evolved to minimize donor-site morbidity and reduce flap-specific complications. When available, the superficial inferior epigastric artery (SIEA) flap represents the optimal method to achieve the former. However, many microsurgeons have been reluctant to adopt this procedure due to technical challenges inherent to the surgery, as well as concerns with the intrinsic capacity of the superficial vessel system to adequately support this flap. This article sets forth a simple approach to the SIEA flap harvest and demonstrates that favorable results may be achieved even for small caliber vessels. A total of 46 patients underwent 53 SIEA breast reconstructions over a 6-year period using a modified approach for pedicle dissection and arterial inclusion criteria solely on the basis of presence of a palpable pulse. Average pedicle length harvested for all SIEA flaps was 6.07 cm; and mean arterial (0.96 mm) and venous (2.27 mm) diameters represent the lowest published values. Three flaps (5.7%) demonstrated fat necrosis or partial flap necrosis, with one (1.9%) complete flap loss. These results compare favorably with those of previous SIEA series employing diameter-based selection criteria, suggesting that the presence of a palpable arterial pulse may be sufficient to permit successful utilization of this flap. (c) Thieme Medical Publishers.

  13. Integration of a capacitive pressure sensing system into the outer catheter wall for coronary artery FFR measurements

    NASA Astrophysics Data System (ADS)

    Stam, Frank; Kuisma, Heikki; Gao, Feng; Saarilahti, Jaakko; Gomes Martins, David; Kärkkäinen, Anu; Marrinan, Brendan; Pintal, Sebastian

    2017-05-01

    The deadliest disease in the world is coronary artery disease (CAD), which is related to a narrowing (stenosis) of blood vessels due to fatty deposits, plaque, on the arterial walls. The level of stenosis in the coronary arteries can be assessed by Fractional Flow Reserve (FFR) measurements. This involves determining the ratio between the maximum achievable blood flow in a diseased coronary artery and the theoretical maximum flow in a normal coronary artery. The blood flow is represented by a pressure drop, thus a pressure wire or pressure sensor integrated in a catheter can be used to calculate the ratio between the coronary pressure distal to the stenosis and the normal coronary pressure. A 2 Fr (0.67mm) outer diameter catheter was used, which required a high level of microelectronics miniaturisation to fit a pressure sensing system into the outer wall. The catheter has an eccentric guidewire lumen with a diameter of 0.43mm, which implies that the thickest catheter wall section provides less than 210 microns height for flex assembly integration consisting of two dies, a capacitive MEMS pressure sensor and an ASIC. In order to achieve this a very thin circuit flex was used, and the two chips were thinned down to 75 microns and flip chip mounted face down on the flex. Many challenges were involved in obtaining a flex layout that could wrap into a small tube without getting the dies damaged, while still maintaining enough flexibility for the catheter to navigate the arterial system.

  14. Angiographic Anatomy of External Iliac Arteries in the Sheep.

    PubMed

    Joscht, M; Martin, M; Henin, M; Nisolle, J F; Kirschvink, N; Dugdale, A; Godart, B; Coulon, H; Simon, V; Hontoir, F; Graffin, R; De Raeve, Y; Vandeweerd, J M

    2016-12-01

    External iliac artery atherosclerotic disease and aneurism occur in man. For treatment, imaging is required to facilitate minimally invasive introduction and advancement of stents within the intended vessels. Sheep are commonly used to test and improve stents. However, little information is published regarding the angiographic anatomy of the iliac arteries in the ovine species. The objective of this study was to describe the angiographic anatomy of the iliac arteries in the sheep. Computed tomography (CT) angiography and gross anatomical dissection were performed in, respectively, 10 and 43 adult ewes. Diameters and lengths of the arteries were measured. In comparison with man, salient anatomical differences were identified in the sheep: (1) the absence of common iliac arteries, (2) the common trunk at the origin of internal iliac arteries and (3) the location of the bifurcation of the external iliac arteries into femoral arteries in the pelvis (not in the limb). External iliac arteries in this series of sheep were 86 mm long in average and had a mean diameter of 7.5 mm. Lengths of arteries are only slightly different between man and sheep, while diameters are rather similar. Therefore, the sheep model appears to be sufficiently similar to man to test stent properties. This study provides useful reference images and measures of lengths and diameters of relevant arteries that could be applied to research with ovine models. © 2015 Blackwell Verlag GmbH.

  15. Arterial endothelial function measurement method and apparatus

    DOEpatents

    Maltz, Jonathan S; Budinger, Thomas F

    2014-03-04

    A "relaxoscope" (100) detects the degree of arterial endothelial function. Impairment of arterial endothelial function is an early event in atherosclerosis and correlates with the major risk factors for cardiovascular disease. An artery (115), such as the brachial artery (BA) is measured for diameter before and after several minutes of either vasoconstriction or vasorelaxation. The change in arterial diameter is a measure of flow-mediated vasomodification (FMVM). The relaxoscope induces an artificial pulse (128) at a superficial radial artery (115) via a linear actuator (120). An ultrasonic Doppler stethoscope (130) detects this pulse 10-20 cm proximal to the point of pulse induction (125). The delay between pulse application and detection provides the pulse transit time (PTT). By measuring PTT before (160) and after arterial diameter change (170), FMVM may be measured based on the changes in PTT caused by changes in vessel caliber, smooth muscle tone and wall thickness.

  16. Giant cell arteritis of fallopian tube.

    PubMed

    Azzena, A; Altavilla, G; Salmaso, R; Vasoin, F; Pellizzari, P; Doria, A

    1994-01-01

    One case of giant cells arteritis involving tubaric arteries in a postmenopausal woman is described. The patient was 59 years old and presented with asthenia, anemia, fever, weight loss, an abdominal palpable mass and elevated erythrocyte sedimentation rate. Exploratory laparotomy revealed a large ovarian cyst of 14 cm in diameter. Extensive giant cell arteritis, Horton's type, of the small-sizes arteries was found unexpectedly in the fallopian tube of the patient who had had a prior ovariectomy. Giant cell arteritis of the female genital tract is a rare finding in elderly women and may occur as an isolated finding or as part of generalised arteritis.

  17. Increased Arterial Diameters in the Posterior Cerebral Circulation in Men with Fabry Disease

    PubMed Central

    Üçeyler, Nurcan; Homola, György A.; Guerrero González, Hans; Kramer, Daniela; Wanner, Christoph; Weidemann, Frank; Solymosi, László; Sommer, Claudia

    2014-01-01

    A high load of white matter lesions and enlarged basilar arteries have been shown in selected patients with Fabry disease, a disorder associated with an increased stroke risk. We studied a large cohort of patients with Fabry disease to differentially investigate white matter lesion load and cerebral artery diameters. We retrospectively analyzed cranial magnetic resonance imaging scans of 87 consecutive Fabry patients, 20 patients with ischemic stroke, and 36 controls. We determined the white matter lesion load applying the Fazekas score on fluid-attenuated inversion recovery sequences and measured the diameters of cerebral arteries on 3D-reconstructions of the time-of-flight-MR-angiography scans. Data of different Fabry patient subgroups (males – females; normal – impaired renal function) were compared with data of patients with stroke and controls. A history of stroke or transient ischemic attacks was present in 4/30 males (13%) and 5/57 (9%) females with Fabry disease, all in the anterior circulation. Only one man with Fabry disease showed confluent cerebral white matter lesions in the Fazekas score assessment (1%). Male Fabry patients had a larger basilar artery (p<0.01) and posterior cerebral artery diameter (p<0.05) compared to male controls. This was independent of disease severity as measured by renal function and did not lead to changes in arterial blood flow properties. A basilar artery diameter of >3.2 mm distinguished between men with Fabry disease and controls (sensitivity: 87%, specificity: 86%, p<0.001), but not from stroke patients. Enlarged arterial diameters of the posterior circulation are present only in men with Fabry disease independent of disease severity. PMID:24475221

  18. Gas-driven pump for ground-water samples

    USGS Publications Warehouse

    Signor, Donald C.

    1978-01-01

    Observation wells installed for artificial-recharge research and other wells used in different ground-water programs are frequently cased with small-diameter steel pipe. To obtain samples from these small-diameter wells in order to monitor water quality, and to calibrate solute-transport models, a small-diameter pump with unique operating characteristics is required that causes a minimum alternation of samples during field sampling. A small-diameter gas-driven pump was designed and built to obtain water samples from wells of two-inch diameter or larger. The pump is a double-piston type with the following characteristics: (1) The water sample is isolated from the operating gas, (2) no source of electricity is ncessary, (3) operation is continuous, (4) use of compressed gas is efficient, and (5) operation is reliable over extended periods of time. Principles of operation, actual operation techniques, gas-use analyses and operating experience are described. Complete working drawings and a component list are included. Recent modifications and pump construction for high-pressure applications also are described. (Woodard-USGS)

  19. Bioresorbable Scaffold for Treatment of Coronary Artery Lesions: Intravascular Ultrasound Results From the ABSORB Japan Trial.

    PubMed

    Okada, Kozo; Honda, Yasuhiro; Kitahara, Hideki; Otagiri, Kyuhachi; Tanaka, Shigemitsu; Hollak, M Brooke; Yock, Paul G; Popma, Jeffrey J; Kusano, Hajime; Cheong, Wai-Fung; Sudhir, Krishnankutty; Fitzgerald, Peter J; Kimura, Takeshi

    2018-04-09

    The aim of this study was to characterize post-procedural intravascular ultrasound (IVUS) findings in the ABSORB Japan trial, specifically stratified by the size of target coronary arteries. Despite overall noninferiority confirmed in recent randomized trials comparing bioresorbable vascular scaffolds (BVS) (Absorb BVS) and cobalt-chromium everolimus-eluting metallic stents (CoCr-EES), higher event rates of Absorb BVS have been reported with suboptimal deployment, especially in small coronary arteries. In the ABSORB Japan trial, 150 patients (2:1 randomization) were scheduled in the IVUS cohort. Small vessel was defined as mean reference lumen diameter <2.75 mm. Tapered-vessel lesions were defined as tapering index (proximal/distal reference lumen diameter) ≥1.2. Overall, IVUS revealed that the Absorb BVS arm had smaller device expansion than the CoCr-EES arm did, which was particularly prominent in small- and tapered-vessel lesions. Higher tapering index was also associated with higher rates of incomplete strut apposition in Absorb BVS, but not in CoCr-EES. With respect to procedural techniques, small-vessel lesions were treated more frequently with noncompliant balloons at post-dilatation but using significantly lower pressure in the Absorb BVS arm. In contrast, tapered-vessel lesions were post-dilated at equivalent pressure but with significantly smaller balloon catheters in the Absorb BVS arm, compared with the CoCr-EES arm. The significantly smaller device expansion especially in small vessels may account for the poorer outcomes of Absorb BVS in this lesion type. Appropriate optimization strategy, possibly different between polymeric and metallic devices, needs to be established for bioresorbable scaffold technology. (AVJ-301 Clinical Trial: A Clinical Evaluation of AVJ-301 Absorb™ BVS) in Japanese Population [ABSORB JAPAN]; NCT01844284). Copyright © 2018 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  20. Bypass of the maxillary artery to proximal middle cerebral artery.

    PubMed

    Ma, Lin; Ren, He-cheng; Huang, Ying

    2015-03-01

    The objective of this work was to explore the feasibility of bypass between the maxillary artery (MA) and proximity of middle cerebral artery (MCA). Ten fixed and perfused adult cadaver heads were dissected bilaterally, 20 sides in total. The superficial temporal artery and its 2 branches were dissected, and outer diameters were measured. The MA and its branch were exposed as well as deep temporal artery; outer diameter of MA was measured. The lengths between the external carotid artery, internal carotid artery, maxillary artery, and proximal middle cerebral artery were measured. Ten healthy adults as targets (20 sides), inner diameter and blood flow dynamic parameters of the common carotid artery, external carotid artery, internal carotid artery, maxillary artery, superficial temporal artery, and its 2 branches were done with ultrasound examination. The mean outer diameter of MA (2.60 ± 0.20 mm) was larger than that of the temporal artery trunk (1.70 ± 0.30 mm). The mean lengths of graft vessels between the internal carotid artery, external carotid artery, and the bifurcation section of MCA (171.00 ± 2.70 and 162.40 ± 2.60 mm) were longer than the mean lengths of graft vessels between MA and MCA bifurcation section (61.70 ± 1.50 mm). In adults, the mean blood flow of the second part of MA (62.70 ± 13.30 mL/min) was more than that of the 2 branches of the superficial temporal artery (15.90 ± 3.70 mL/min and 17.70 ± 4.10 ml/min). Bypass between the maxillary artery and proximity of middle cerebral artery is feasible. It is a kind of effective high flow bypass with which the graft vessel is shorter and straighter than the bypass between internal carotid artery or external carotid artery and proximity of middle cerebral artery.

  1. High-resolution computed tomography evaluation of the bronchial lumen to vertebral body diameter and pulmonary artery to vertebral body diameter ratios in anesthetized ventilated normal cats.

    PubMed

    Lee-Fowler, Tekla M; Cole, Robert C; Dillon, A Ray; Tillson, D Michael; Garbarino, Rachel; Barney, Sharron

    2017-10-01

    Objectives Bronchial lumen to pulmonary artery diameter (BA) ratio has been utilized to investigate pulmonary pathology on high-resolution CT images. Diseases affecting both the bronchi and pulmonary arteries render the BA ratio less useful. The purpose of the study was to establish bronchial lumen diameter to vertebral body diameter (BV) and pulmonary artery diameter to vertebral body diameter (AV) ratios in normal cats. Methods Using high-resolution CT images, 16 sets of measurements (sixth thoracic vertebral body [mid-body], each lobar bronchi and companion pulmonary artery diameter) were acquired from young adult female cats and 41 sets from pubertal female cats. Results Young adult and pubertal cat BV ratios were not statistically different from each other in any lung lobe. Significant differences between individual lung lobe BV ratios were noted on combined age group analysis. Caudal lung lobe AV ratios were significantly different between young adult and pubertal cats. All other lung lobe AV ratios were not significantly different. Caudal lung lobe AV ratios were significantly different from all other lung lobes but not from each other in both the young adult and pubertal cats. Conclusions and relevance BV ratio reference intervals determined for individual lung lobes could be applied to both young adult and pubertal cats. Separate AV ratios for individual lung lobes would be required for young adult and pubertal cats. These ratios should allow more accurate evaluation of cats with concurrent bronchial and pulmonary arterial disease.

  2. Histomorphometric study of brachiocephalic artery of Japanese quail

    PubMed Central

    Shariati, Sarah; Rahmanifar, Farhad; Tamadon, Amin

    2015-01-01

    Brachiocephalic arteries in quails are large arteries which are arising separately from the aortic arch. The aim of the present study was to determine the histomorphometric aspects of brachiocephalic arteries in the Japanese quail. The different layers of the brachiocephalic artery were studied quantitatively in 10, 20 and 60 days-old Japanese quail; (n = 6) and both sexes. Luminal diameter, thickness of the intima, media and adventitia, the percentage of the intima, media and adventitia, as compared with the total wall thickness were determined. It was found that luminal diameter and whole artery thickness increased by age (p < 0.05). In addition, the tunica media was the thickest layer, then tunica intima and at last tunica adventitia (p < 0.05). The muscularity of the right brachiocephalic artery was more than that of the left one (p < 0.05). Histomorphometric study of brachiocephalic arteries of Japanese quails showed that increasing of age causes increase of internal and external diameters of the artery and this increase in females was more than males. PMID:26893806

  3. Histomorphometric study of brachiocephalic artery of Japanese quail.

    PubMed

    Shariati, Sarah; Rahmanifar, Farhad; Tamadon, Amin

    2015-01-01

    Brachiocephalic arteries in quails are large arteries which are arising separately from the aortic arch. The aim of the present study was to determine the histomorphometric aspects of brachiocephalic arteries in the Japanese quail. The different layers of the brachiocephalic artery were studied quantitatively in 10, 20 and 60 days-old Japanese quail; (n = 6) and both sexes. Luminal diameter, thickness of the intima, media and adventitia, the percentage of the intima, media and adventitia, as compared with the total wall thickness were determined. It was found that luminal diameter and whole artery thickness increased by age (p < 0.05). In addition, the tunica media was the thickest layer, then tunica intima and at last tunica adventitia (p < 0.05). The muscularity of the right brachiocephalic artery was more than that of the left one (p < 0.05). Histomorphometric study of brachiocephalic arteries of Japanese quails showed that increasing of age causes increase of internal and external diameters of the artery and this increase in females was more than males.

  4. Computational Assessment of Blood Flow Heterogeneity in Peritoneal Dialysis Patients' Cardiac Ventricles

    PubMed Central

    Kharche, Sanjay R.; So, Aaron; Salerno, Fabio; Lee, Ting-Yim; Ellis, Chris; Goldman, Daniel; McIntyre, Christopher W.

    2018-01-01

    Dialysis prolongs life but augments cardiovascular mortality. Imaging data suggests that dialysis increases myocardial blood flow (BF) heterogeneity, but its causes remain poorly understood. A biophysical model of human coronary vasculature was used to explain the imaging observations, and highlight causes of coronary BF heterogeneity. Post-dialysis CT images from patients under control, pharmacological stress (adenosine), therapy (cooled dialysate), and adenosine and cooled dialysate conditions were obtained. The data presented disparate phenotypes. To dissect vascular mechanisms, a 3D human vasculature model based on known experimental coronary morphometry and a space filling algorithm was implemented. Steady state simulations were performed to investigate the effects of altered aortic pressure and blood vessel diameters on myocardial BF heterogeneity. Imaging showed that stress and therapy potentially increased mean and total BF, while reducing heterogeneity. BF histograms of one patient showed multi-modality. Using the model, it was found that total coronary BF increased as coronary perfusion pressure was increased. BF heterogeneity was differentially affected by large or small vessel blocking. BF heterogeneity was found to be inversely related to small blood vessel diameters. Simulation of large artery stenosis indicates that BF became heterogeneous (increase relative dispersion) and gave multi-modal histograms. The total transmural BF as well as transmural BF heterogeneity reduced due to large artery stenosis, generating large patches of very low BF regions downstream. Blocking of arteries at various orders showed that blocking larger arteries results in multi-modal BF histograms and large patches of low BF, whereas smaller artery blocking results in augmented relative dispersion and fractal dimension. Transmural heterogeneity was also affected. Finally, the effects of augmented aortic pressure in the presence of blood vessel blocking shows differential effects on BF heterogeneity as well as transmural BF. Improved aortic blood pressure may improve total BF. Stress and therapy may be effective if they dilate small vessels. A potential cause for the observed complex BF distributions (multi-modal BF histograms) may indicate existing large vessel stenosis. The intuitive BF heterogeneity methods used can be readily used in clinical studies. Further development of the model and methods will permit personalized assessment of patient BF status. PMID:29867555

  5. Pulmonary arterial hypertension in children: diagnosis using ratio of main pulmonary artery to ascending aorta diameter as determined by multi-detector computed tomography.

    PubMed

    Caro-Domínguez, Pablo; Compton, Gregory; Humpl, Tilman; Manson, David E

    2016-09-01

    The ratio of the transverse diameter of the main pulmonary artery (MPA) to ascending aorta as determined at multi-detector CT is a tool that can be used to assess the pulmonary arterial size in cases of pulmonary arterial hypertension in children. To establish a ratio of MPA to ascending aorta diameter using multi-detector CT imaging suggestive of pulmonary arterial hypertension in children. We hypothesize that a defined ratio of MPA to ascending aorta is identifiable on multi-detector CT and that higher ratios can be used to reliably diagnose the presence of pulmonary arterial hypertension in children. We calculated the multi-detector CT ratio of MPA to ascending aorta diameter in 44 children with documented pulmonary arterial hypertension by right heart catheterization and in 44 age- and gender-matched control children with no predisposing factors for pulmonary arterial hypertension. We compared this multi-detector-CT-determined ratio with the MPA pressure in the study group, as well as with the ratio of MPA to ascending aorta in the control group. A threshold ratio value was calculated to accurately identify children with pulmonary arterial hypertension. Children with documented primary pulmonary arterial hypertension have a significantly higher ratio of MPA to ascending aorta (1.46) than children without pulmonary arterial hypertension (1.11). A ratio of 1.3 carries a positive likelihood of 34 and a positive predictive value of 97% for the diagnosis of pulmonary arterial hypertension. The pulmonary arteries were larger in children with pulmonary arterial hypertension than in a control group of normal children. A CT-measured ratio of MPA to ascending aorta of 1.3 should raise the suspicion of pulmonary arterial hypertension in children.

  6. Effects of posture on shear rates in human brachial and superficial femoral arteries

    PubMed Central

    Newcomer, S. C.; Sauder, C. L.; Kuipers, N. T.; Laughlin, M. H.; Ray, C. A.

    2012-01-01

    Shear rate is significantly lower in the superficial femoral compared with the brachial artery in the supine posture. The relative shear rates in these arteries of subjects in the upright posture (seated and/or standing) are unknown. The purpose of this investigation was to test the hypothesis that upright posture (seated and/or standing) would produce greater shear rates in the superficial femoral compared with the brachial artery. To test this hypothesis, Doppler ultrasound was used to measure mean blood velocity (MBV) and diameter in the brachial and superficial femoral arteries of 21 healthy subjects after being in the supine, seated, and standing postures for 10 min. MBV was significantly higher in the brachial compared with the superficial femoral artery during upright postures. Superficial femoral artery diameter was significantly larger than brachial artery diameter. However, posture had no significant effect on either brachial or superficial femoral artery diameter. The calculated shear rate was significantly greater in the brachial (73 ± 5, 91 ± 11, and 97 ± 13 s−1) compared with the superficial femoral (53 ± 4, 39 ± 77, and 44 ± 5 s−1) artery in the supine, seated, and standing postures, respectively. Contrary to our hypothesis, our current findings indicate that mean shear rate is lower in the superficial femoral compared with the brachial artery in the supine, seated, and standing postures. These findings of lower shear rates in the superficial femoral artery may be one mechanism for the higher propensity for atherosclerosis in the arteries of the leg than of the arm. PMID:18245564

  7. Risk Factors for the Rupture of Intracranial Aneurysms Using Computed Tomography Angiography.

    PubMed

    Wang, Guang-Xian; Wen, Li; Yang, Liu; Zhang, Qi-Chuang; Yin, Jin-Bo; Duan, Chun-Mei; Zhang, Dong

    2018-02-01

    To study the clinical and morphologic characteristics associated with risk factors for the rupture of intracranial aneurysms (IAs). A total of 1115 consecutive patients with 1282 IAs were reviewed from August 2011 to February 2016. The patients and IAs were divided into ruptured and unruptured groups. Based on the clinical and morphologic findings, the risk factors for IA rupture were assessed using statistical methods. Age, hypertension, diabetes mellitus, and cerebral atherosclerosis were associated with ruptured IAs. IAs located in the anterior cerebral artery, the anterior communicating artery, the posterior communicating artery, and the internal carotid artery were associated with ruptured IAs. Ruptures were also associated with arterial bifurcations, irregular aneurysm shapes, and all continuous data, except neck width. Binary logistic regression showed that IAs located at bifurcations (odds ratio [OR], 1.804), with irregular shapes (OR, 4.677), with high aspect ratios (ARs) (OR, 5.037) or with small mean diameters (MDs) (OR, 0.495) are more prone to rupture. Receiver operating characteristic analysis showed that the threshold values of the AR and MD were 1 and 3.70 mm, respectively. Morphologic characteristics, such as being located at bifurcations, being irregularly shaped, having a high AR (>1), and having a small MD (<3.70 mm), were better predictors of rupture. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Performance of third-trimester ultrasound for prediction of small-for-gestational-age neonates and evaluation of contingency screening policies.

    PubMed

    Souka, A P; Papastefanou, I; Pilalis, A; Michalitsi, V; Kassanos, D

    2012-05-01

    To assess the performance of third-trimester fetal biometry and fetal Doppler studies for the prediction of small-for-gestational-age (SGA) neonates, and to explore contingency strategies using a first-trimester prediction model based on maternal and fetal parameters and third-trimester ultrasound. This was an observational cross-sectional study of uncomplicated singleton pregnancies. Risk assessment for chromosomal abnormality was carried out in 4702 pregnancies using a combination of ultrasound markers (fetal nuchal translucency thickness (NT) and nasal bone assessment) and biochemistry (free beta-human chorionic gonadotropin (β-hCG) and pregnancy-associated plasma protein-A (PAPP-A)) at 11 to 13 + 6 weeks. Maternal demographic characteristics and method of conception were recorded. Third-trimester (30-34 weeks) fetal biometry (biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC) and femur length (FL)) and umbilical artery (UA) and middle cerebral artery Doppler studies were performed routinely in a subgroup (n = 2310). Reference ranges for birth weight were constructed using the cohort of 4702 women, and neonates were classified as small (SGA, ≤ 5th centile) or appropriate (AGA) for gestational age. First-trimester, third-trimester and integrated first- and third-trimester prediction models for SGA were constructed using regression analysis and three different contingency strategies of rescanning in the third trimester were investigated. According to the areas under the receiver-operating characteristics curves (AUCs), AC (AUC = 0.85) and ultrasound-estimated fetal weight (EFW, AUC = 0.87) were equally good predictors of SGA. The model was marginally improved by the addition of UA Doppler, smoking status and first-trimester indices (free β-hCG and PAPP-A multiples of the median) (combined model, AUC = 0.88), but the difference was not statistically significant. A contingency strategy of rescanning 50% of the population in the third trimester according to the risk estimated by a first-trimester prediction model yielded a detection rate of 79% for a 25% screen-positive rate. Third-trimester ultrasound is effective in screening for SGA in uncomplicated pregnancies. The use of a contingency screening policy can reduce the need for unnecessary examinations. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

  9. Segmentation of hepatic artery in multi-phase liver CT using directional dilation and connectivity analysis

    NASA Astrophysics Data System (ADS)

    Wang, Lei; Schnurr, Alena-Kathrin; Zidowitz, Stephan; Georgii, Joachim; Zhao, Yue; Razavi, Mohammad; Schwier, Michael; Hahn, Horst K.; Hansen, Christian

    2016-03-01

    Segmentation of hepatic arteries in multi-phase computed tomography (CT) images is indispensable in liver surgery planning. During image acquisition, the hepatic artery is enhanced by the injection of contrast agent. The enhanced signals are often not stably acquired due to non-optimal contrast timing. Other vascular structure, such as hepatic vein or portal vein, can be enhanced as well in the arterial phase, which can adversely affect the segmentation results. Furthermore, the arteries might suffer from partial volume effects due to their small diameter. To overcome these difficulties, we propose a framework for robust hepatic artery segmentation requiring a minimal amount of user interaction. First, an efficient multi-scale Hessian-based vesselness filter is applied on the artery phase CT image, aiming to enhance vessel structures with specified diameter range. Second, the vesselness response is processed using a Bayesian classifier to identify the most probable vessel structures. Considering the vesselness filter normally performs not ideally on the vessel bifurcations or the segments corrupted by noise, two vessel-reconnection techniques are proposed. The first technique uses a directional morphological operator to dilate vessel segments along their centerline directions, attempting to fill the gap between broken vascular segments. The second technique analyzes the connectivity of vessel segments and reconnects disconnected segments and branches. Finally, a 3D vessel tree is reconstructed. The algorithm has been evaluated using 18 CT images of the liver. To quantitatively measure the similarities between segmented and reference vessel trees, the skeleton coverage and mean symmetric distance are calculated to quantify the agreement between reference and segmented vessel skeletons, resulting in an average of 0:55+/-0:27 and 12:7+/-7:9 mm (mean standard deviation), respectively.

  10. Embolization Materials Made of Gelatin: Comparison Between Gelpart and Gelatin Microspheres

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ohta, Shinichi, E-mail: junryuhei@belle.shiga-med.ac.jp; Nitta, Norihisa; Sonoda, Akinaga

    2010-02-15

    Purpose:The object of this study was to assess the level of embolization in the embolized artery and the degradation period of these two embolic agents in the renal arteries using rabbit models.Materials and Methods: The renal artery was embolized using 5 mg of gelatin microspheres (GMSs; diameter, 35-100 {mu}m; group 1) or 1 mg of Gelpart (diameter, 1 mm; group 2). For each group, angiographies were performed on two kidneys immediately after the embolic procedure and on days 3, 7, and 14 after embolization. This was followed by histopathological examinations of the kidneys.Results:Follow-up angiograms on each day revealed the persistencemore » of poorly enhanced wedge-shaped areas in the parenchymal phase in all cases. In group 1, four of six cases showed poorly enhanced small areas in the follow-up angiograms. In group 2, all cases showed poorly enhanced large areas. In the histopathological specimens, it was observed that immediately after embolization, the particles reached the interlobular arteries in group 1 and the interlobar arteries in group 2. In all cases in group 1, the particles were histologically identified even on day 14. In one case in group 2 on day 14, the particles were not identified.Conclusion:In conclusion, although GMSs and Gelpart were similar in the point of gelatin particles, the level of embolization and the degradation period were different between GMSs and Gelpart.« less

  11. Small-Body Extensions for the Satellite Orbit Analysis Program (SOAP)

    NASA Technical Reports Server (NTRS)

    Carnright, Robert; Stodden, David; Coggi, John

    2008-01-01

    An extension to the SOAP software allows users to work with tri-axial ellipsoid-based representations of planetary bodies, primarily for working with small, natural satellites, asteroids, and comets. SOAP is a widely used tool for the visualization and analysis of space missions. The small body extension provides the same visualization and analysis constructs for use with small bodies. These constructs allow the user to characterize satellite path and instrument cover information for small bodies in both 3D display and numerical output formats. Tri-axial ellipsoids are geometric shapes the diameters of which are different in each of three principal x, y, and z dimensions. This construct provides a better approximation than using spheres or oblate spheroids (ellipsoids comprising two common equatorial diameters as a distinct polar diameter). However, the tri-axial ellipsoid is considerably more difficult to work with from a modeling perspective. In addition, the SOAP small-body extensions allow the user to actually employ a plate model for highly irregular surfaces. Both tri-axial ellipsoids and plate models can be assigned to coordinate frames, thus allowing for the modeling of arbitrary changes to body orientation. A variety of features have been extended to support tri-axial ellipsoids, including the computation and display of the spacecraft sub-orbital point, ground trace, instrument footprints, and swathes. Displays of 3D instrument volumes can be shown interacting with the ellipsoids. Longitude/latitude grids, contour plots, and texture maps can be displayed on the ellipsoids using a variety of projections. The distance along an arbitrary line of sight can be computed between the spacecraft and the ellipsoid, and the coordinates of that intersection can be plotted as a function of time. The small-body extension supports the same visual and analytical constructs that are supported for spheres and oblate spheroids in SOAP making the implementation of the more complex algorithms largely transparent to the user.

  12. Arterial stiffness, body fat compartments, central hemodynamics, renal function and left atrial size.

    PubMed

    Katulska, Katarzyna; Milewska, Agata; Wykretowicz, Mateusz; Krauze, Tomasz; Przymuszala, Dagmara; Piskorski, Jaroslaw; Stajgis, Marek; Guzik, Przemyslaw; Wysocki, Henryk; Wykrętowicz, Andrzej

    2013-10-01

    Left atrial (LA) size is an important predictor of stroke, death, and atrial fibrillation. It was demonstrated recently that body fat, arterial stiffness and renal functions are associated with LA diameter. However, data are lacking for comprehensive assessments of all these risk factors in a single population. Therefore, the aim of the present study was to investigate the association between LA size and different fat descriptors, central hemodynamics, arterial stiffness, and renal function in healthy subjects. To this end, body fat percentage, abdominal, subcutaneous fat, and general descriptors of body fat were estimated in 162 healthy subjects (mean age 51 years). Echocardiography was performed to assess LA diameter. Arterial stiffness and peripheral and central hemodynamics were estimated by digital volume pulse analysis and pulse wave analysis. Glomerular filtration rate was estimated by MDRD formula. There were significant (p < 0.05) bivariate correlations between LA diameter and all descriptors of body fat (except subcutaneous fat). Arterial stiffness and estimated glomerular filtration rate (eGFR) were also significantly correlated with LA size. Multiple regression analysis including all significant confounders, such as sex, mean arterial pressure, arterial stiffness, eGFR and body fat descriptors, explained 35% of variance in LA diameter. In conclusion, the present study reveals significant, independent relationships between body fat, arterial stiffness, and LA size.

  13. A new device for slow progressive narrowing of vessels.

    PubMed

    Lange, P E; Sievers, H H; Nürnberg, J H; Engler, K; Pilarczyk, J; Onnasch, D G; Bernhard, A; Heintzen, P H

    1985-01-01

    The purpose of this work was to develop a device which allows slow progressive banding of a great artery in infants within 4 to 5 weeks. Employed was the hygroscopic casein ameroid. When brought in contact with fluids, an ameroid cylinder expands characteristically. An early phase of fast expansion proceeds gradually to a phase of slow growth. Size, shape, and encasement of ameroid as well as temperature and type of surrounding fluid modify but do not alter the typical pattern of expansion. The developed constrictor (weight: 5.8 kg, length: 18 mm, diameter: 12 mm) includes a stainless steel socket containing an ameroid cylinder (length: 8.5 mm, diameter: 8 mm). The expanding ameroid pushes a piston with a concave extension (makrolon) a maximum of 2 mm against the artery, which is fixed to the metal housing by a teflon band (width: 4 mm, thickness: 0.5 mm). The band runs in 2 fitting grooves on the metal housing to which it is fixed by a metal ring with a precisely manufactured internal thread allowing exact tightening and loosening of the band around the artery. Utilization of inert materials like teflon, makrolon, and stainless steel warrants experimental and possibly clinical application of the developed small constrictor.

  14. Geometric Assortative Growth Model for Small-World Networks

    PubMed Central

    2014-01-01

    It has been shown that both humanly constructed and natural networks are often characterized by small-world phenomenon and assortative mixing. In this paper, we propose a geometrically growing model for small-world networks. The model displays both tunable small-world phenomenon and tunable assortativity. We obtain analytical solutions of relevant topological properties such as order, size, degree distribution, degree correlation, clustering, transitivity, and diameter. It is also worth noting that the model can be viewed as a generalization for an iterative construction of Farey graphs. PMID:24578661

  15. Do Indo-Asians have smaller coronary arteries?

    PubMed

    Lip, G Y; Rathore, V S; Katira, R; Watson, R D; Singh, S P

    1999-08-01

    There is a widespread belief that coronary arteries are smaller in Indo-Asians. The aim of the present study was to compare the size of atheroma-free proximal and distal epicardial coronary arteries of Indo-Asians and Caucasians. We analysed normal coronary angiograms from 77 Caucasians and 39 Indo-Asians. The two groups were comparable for dominance of the coronary arteries. Indo-Asian patients had generally smaller coronary arteries, with a statistically significant difference in the mean diameters of the left main coronary artery, proximal, mid and left anterior descending, and proximal and distal right coronary artery segments. There was a non-significant trend towards smaller coronary artery segment diameters for the distal left anterior descending, proximal and distal circumflex, and obtuse marginal artery segments. However, after correction for body surface area, none of these differences in size were statistically significant. Thus, the smaller coronary arteries in Indo-Asian patients were explained by body size alone and were not due to ethnic origin per se. This finding nevertheless has important therapeutic implications, since smaller coronary arteries may give rise to technical difficulties during bypass graft and intervention procedures such as percutaneous transluminal coronary angioplasty, stents and atherectomy. On smaller arteries, atheroma may also give an impression of more severe disease than on larger diameter arteries.

  16. A one-dimensional model of flow in a junction of thin channels, including arterial trees

    NASA Astrophysics Data System (ADS)

    Kozlov, V. A.; Nazarov, S. A.

    2017-08-01

    We study a Stokes flow in a junction of thin channels (of diameter O(h)) for fixed flows of the fluid at the inlet cross-sections and fixed peripheral pressure at the outlet cross-sections. On the basis of the idea of the pressure drop matrix, apart from Neumann conditions (fixed flow) and Dirichlet conditions (fixed pressure) at the outer vertices, the ordinary one-dimensional Reynolds equations on the edges of the graph are equipped with transmission conditions containing a small parameter h at the inner vertices, which are transformed into the classical Kirchhoff conditions as h\\to+0. We establish that the pre-limit transmission conditions ensure an exponentially small error O(e-ρ/h), ρ>0, in the calculation of the three-dimensional solution, but the Kirchhoff conditions only give polynomially small error. For the arterial tree, under the assumption that the walls of the blood vessels are rigid, for every bifurcation node a ( 2×2)-pressure drop matrix appears, and its influence on the transmission conditions is taken into account by means of small variations of the lengths of the graph and by introducing effective lengths of the one-dimensional description of blood vessels whilst keeping the Kirchhoff conditions and exponentially small approximation errors. We discuss concrete forms of arterial bifurcation and available generalizations of the results, in particular, the Navier-Stokes system of equations. Bibliography: 59 titles.

  17. Magnetic guide-wire navigation in pulmonary and systemic arterial catheterization: initial experience in pigs.

    PubMed

    Grosse-Wortmann, Lars; Grabitz, Ralf; Seghaye, Marie-Christine

    2007-04-01

    Cardiovascular catheterization can be challenging whenever a stenosis or an abnormal vascular course interferes with probing the target vessel. This study addresses the feasibility of navigating a guide wire with a magnetic tip by an external magnetic field through pulmonary and systemic arteries in an experimental porcine model. We investigated six piglets using magnetic guide-wire navigation. Two pulmonary arteriograms were taken from different angles in order to reconstruct the three-dimensional vessel anatomy. A computer interface then calculated three-dimensional coordinates for the vessel in space. Using these coordinates, two external magnets were positioned to create magnetic vectors along the expected vessel course. Magnetically enabled guide wires were then navigated into the vessels using the magnetic field to orient the guide-wire tips. Aortic and renal branches were addressed in a similar fashion. Difficulty in reaching the target vessel was reflected by the number of attempts that were necessary. After 10 failed attempts, the maneuver was recorded to have failed. Thirty-five of 37 (94.6%) arteries with branches at acute angles were reached successfully using magnetic navigation. In two pigs, the left upper lobe artery could not be probed. Peripheral arteries of small diameter were easier to reach than large central arteries, requiring less attempts. Magnetic guide-wire navigation is feasible in the arteries of the lungs, the head and neck, and the kidneys. It is particularly useful in entering small arterial branches at acute angles and may facilitate interventional therapy in a variety of vascular diseases in children and adults.

  18. Building America Case Study: Standard- Versus High-Velocity Air Distribution in High-Performance Townhomes, Denver, Colorado

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    IBACOS investigated the performance of a small-diameter high velocity heat pump system compared to a conventional system in a new construction triplex townhouse. A ductless heat pump system also was installed for comparison, but the homebuyer backed out because of aesthetic concerns about that system. In total, two buildings, having identical solar orientation and comprised of six townhomes, were monitored for comfort and energy performance. Results show that the small-diameter system provides more uniform temperatures from floor to floor in the three-story townhome. No clear energy consumption benefit was observed from either system. The builder is continuing to explore themore » small-diameter system as its new standard system to provide better comfort and indoor air quality. The homebuilder also explored the possibility of shifting its townhome product to meet the U.S. Department of Energy Challenge Home National Program Requirements. Ultimately, the builder decided that adoption of these practices would be too disruptive midstream in the construction cycle. However, the townhomes met the ENERGY STAR Version 3.0 program requirements.« less

  19. Comparative Cooling Season Performance of Air Distribution Systems in Multistory Townhomes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poerschke, Andrew; Beach, Rob; Beggs, Timothy

    2016-08-01

    IBACOS investigated the performance of a small-diameter high velocity heat pump system compared to a conventional system in a new construction triplex townhouse. A ductless heat pump system also was installed for comparison, but the homebuyer backed out because of aesthetic concerns about that system. In total, two buildings, having identical solar orientation and comprised of six townhomes, were monitored for comfort and energy performance. Results show that the small-diameter system provides more uniform temperatures from floor to floor in the three-story townhome. No clear energy consumption benefit was observed from either system. The builder is continuing to explore themore » small-diameter system as its new standard system to provide better comfort and indoor air quality. The homebuilder also explored the possibility of shifting its townhome product to meet the U.S. Department of Energy Challenge Home National Program Requirements. Ultimately, the builder decided that adoption of these practices would be too disruptive midstream in the construction cycle. However, the townhomes met the ENERGY STAR Version 3.0 program requirements.« less

  20. Hemodynamic Based Coronary Artery Aneurysm Thrombosis Risk Stratification in Kawasaki Disease Patients

    NASA Astrophysics Data System (ADS)

    Grande Gutierrez, Noelia; Mathew, M.; McCrindle, B.; Kahn, A.; Burns, J.; Marsden, A.

    2017-11-01

    Coronary artery aneurysms (CAA) as a result of Kawasaki Disease (KD) put patients at risk for thrombosis and myocardial infarction. Current AHA guidelines recommend CAA diameter >8 mm or Z-score >10 as the criterion for initiating systemic anticoagulation. Our hypothesis is that hemodynamic data derived from computational blood flow simulations is a better predictor of thrombosis than aneurysm diameter alone. Patient-specific coronary models were constructed from CMRI for a cohort of 10 KD patients (5 confirmed thrombosis cases) and simulations with fluid structure interaction were performed using the stabilized finite element Navier-Stokes solver available in SimVascular. We used a closed-loop lumped parameter network (LPN) to model the heart and vascular boundary conditions coupled numerically to the flow solver. An automated parameter estimation method was used to match LPN values to clinical data for each patient. Hemodynamic data analysis resulted in low correlation between Wall Shear Stress (WSS)/ Particle Residence Time (PRT) and CAA diameter but demonstrates the positive correlation between hemodynamics and adverse patient outcomes. Our results suggest that quantifying WSS and PRT should enable identification of regions at higher risk of thrombosis. We propose a quantitative method to non-invasively assess the abnormal flow in CAA following KD that could potentially improve clinical decision-making regarding anticoagulation therapy.

  1. Laser tissue welding mediated with a protein solder

    NASA Astrophysics Data System (ADS)

    Small, Ward, IV; Heredia, Nicholas J.; Celliers, Peter M.; Da Silva, Luiz B.; Eder, David C.; Glinsky, Michael E.; London, Richard A.; Maitland, Duncan J.; Matthews, Dennis L.; Soltz, Barbara A.

    1996-05-01

    A study of laser tissue welding mediated with an indocyanine green dye-enhanced protein solder was performed. Freshly obtained sections of porcine artery were used for the experiments. Sample arterial wall thickness ranged from two to three millimeters. Incisions approximately four millimeters in length were treated using an 805 nanometer continuous- wave diode laser coupled to a one millimeter diameter fiber. Controlled parameters included the power delivered by the laser, the duration of the welding process, and the concentration of dye in the solder. A two-color infrared detection system was constructed to monitor the surface temperatures achieved at the weld site. Burst pressure measurements were made to quantify the strengths of the welds immediately following completion of the welding procedure.

  2. Arterial tree tracking from anatomical landmarks in magnetic resonance angiography scans

    NASA Astrophysics Data System (ADS)

    O'Neil, Alison; Beveridge, Erin; Houston, Graeme; McCormick, Lynne; Poole, Ian

    2014-03-01

    This paper reports on arterial tree tracking in fourteen Contrast Enhanced MRA volumetric scans, given the positions of a predefined set of vascular landmarks, by using the A* algorithm to find the optimal path for each vessel based on voxel intensity and a learnt vascular probability atlas. The algorithm is intended for use in conjunction with an automatic landmark detection step, to enable fully automatic arterial tree tracking. The scan is filtered to give two further images using the top-hat transform with 4mm and 8mm cubic structuring elements. Vessels are then tracked independently on the scan in which the vessel of interest is best enhanced, as determined from knowledge of typical vessel diameter and surrounding structures. A vascular probability atlas modelling expected vessel location and orientation is constructed by non-rigidly registering the training scans to the test scan using a 3D thin plate spline to match landmark correspondences, and employing kernel density estimation with the ground truth center line points to form a probability density distribution. Threshold estimation by histogram analysis is used to segment background from vessel intensities. The A* algorithm is run using a linear cost function constructed from the threshold and the vascular atlas prior. Tracking results are presented for all major arteries excluding those in the upper limbs. An improvement was observed when tracking was informed by contextual information, with particular benefit for peripheral vessels.

  3. Retinal Arterioles in Hypo-, Normo-, and Hypertensive Subjects Measured Using Adaptive Optics.

    PubMed

    Hillard, Jacob G; Gast, Thomas J; Chui, Toco Y P; Sapir, Dan; Burns, Stephen A

    2016-08-01

    Small artery and arteriolar walls thicken due to elevated blood pressure. Vascular wall thickness show a correlation with hypertensive subject history and risk for stroke and cardiovascular events. The inner and outer diameter of retinal arterioles from less than 10 to over 150 μm were measured using a multiply scattered light adaptive optics scanning laser ophthalmoscope (AOSLO). These measurements were made on three populations, one with habitual blood pressures less than 100/70 mm Hg, one with normal blood pressures without medication, and one with managed essential hypertension. The wall to lumen ratio was largest for the smallest arterioles for all three populations. Data from the hypotensive group had a linear relationship between outer and inner diameters ( r 2 = 0.99) suggesting a similar wall structure in individuals prior to elevated blood pressures. Hypertensive subjects fell below the 95% confidence limits for the hypotensive relationship and had larger wall to lumen ratios and the normotensive group results fell between the other two groups. High-resolution retinal imaging of subjects with essential hypertension showed a significant decrease in vessel inner diameter for a given outer diameter, and increases in wall to lumen ratio and wall cross-sectional areas over the entire range of vessel diameters and suggests that correcting for vessel size may improve the ability to identify significant vascular changes. High-resolution imaging allows precise measurement of vasculature and by comparing results across risk populations may allow improved identification of individuals undergoing hypertensive arterial wall remodeling.

  4. Demonstration and Validation of a Regenerated Cellulose Dialysis Membrane Diffusion Sampler for Monitoring Ground Water Quality and Remediation Progress at DoD Sites for Perchlorate and Explosives Compounds

    DTIC Science & Technology

    2010-09-01

    Regulatory Council LRL Laboratory reporting level LDPE Low-density polyethylene MDL Minimum detection limit MNA Monitored natural attenuation...consists of a tubular-shaped bag made of flexible low-density polyethylene ( LDPE ) (Vroblesky, 2001a, 2001b). The LDPE tube is heat-sealed on one end...be constructed from small- diameter LDPE tubing that fits into small-diameter wells. These polyethylene diffusion bag (PDB) samplers have been

  5. Demonstration and Validation of a Regenerated Cellulose Dialysis Membrane Diffusion Sampler for Monitoring Ground-Water Quality and Remediation Progress at DoD Site: Perchlorate and Ordnance Compounds

    DTIC Science & Technology

    2011-10-01

    Regulatory Council LDPE low-density polyethylene MDL minimum detection limit NAVFAC ESC Naval Facilities Engineering Command Engineering Service...membrane sampler design consists of a tubular-shaped bag made of flexible low-density polyethylene ( LDPE ) (Vroblesky, 2001a, 2001b). The LDPE tube is...requirements, and can be constructed from small-diameter LDPE tubing that fits into small- 4 diameter wells. These polyethylene diffusion bag

  6. Coronary artery size and disease in UK South Asian and Caucasian men.

    PubMed

    Zindrou, Dlear; Taylor, Kenneth M; Bagger, Jens Peder

    2006-04-01

    South Asian patients in the UK have a higher mortality rate after coronary artery bypass grafting (CABG) than Caucasian patients. As coronary artery size has been shown to correlate to outcome from bypass grafting, it has been suggested that smaller coronary arteries in South Asians as compared to Caucasians could contribute to a poorer outcome in the Asian population. We aimed to measure coronary artery size and disease in matched South Asian and Caucasian men undergoing first time coronary artery bypass grafting. Coronary arteriograms from 53 matched first generation South Asian and Caucasian men were examined. The patients had no history of myocardial infarction, coronary revascularisation, familial dyslipidaemia, diabetes or renal disease. They were individually matched for age, height, weight, body mass index and body surface area. Thereafter, coronary artery diameters and significant (> or =50%) diameter stenoses were measured in a blinded fashion using quantitative coronary angiography (QCA). In South Asian men, diameters of the left main stem (LMS) and the proximal left anterior descending, the circumflex and the right coronary arteries were 4.6+/-0.9 mm, 3.5+/-0.8 mm, 3.4+/-0.8 mm and 3.5+/-0.8 mm, respectively. The corresponding arterial diameters among Caucasian men (4.5+/-0.9 mm, 3.5+/-0.7 mm, 3.5+/-0.8 mm and 3.8+/-0.8 mm) did not differ from those in South Asians. There was no difference in the number of significant coronary artery stenoses between the two groups and no difference in bypass and cross-clamp times or in adverse outcome (one from each group died after coronary artery bypass grafting). Proximal coronary artery size and number of significant coronary stenoses did not differ between matched pairs of South Asian and Caucasian men using strict inclusion/exclusion criteria.

  7. Small-bubble transport and splitting dynamics in a symmetric bifurcation.

    PubMed

    Qamar, Adnan; Warnez, Matthew; Valassis, Doug T; Guetzko, Megan E; Bull, Joseph L

    2017-08-01

    Simulations of small bubbles traveling through symmetric bifurcations are conducted to garner information pertinent to gas embolotherapy, a potential cancer treatment. Gas embolotherapy procedures use intra-arterial bubbles to occlude tumor blood supply. As bubbles pass through bifurcations in the blood stream nonhomogeneous splitting and undesirable bioeffects may occur. To aid development of gas embolotherapy techniques, a volume of fluid method is used to model the splitting process of gas bubbles passing through artery and arteriole bifurcations. The model reproduces the variety of splitting behaviors observed experimentally, including the bubble reversal phenomenon. Splitting homogeneity and maximum shear stress along the vessel walls is predicted over a variety of physical parameters. Small bubbles, having initial length less than twice the vessel diameter, were found unlikely to split in the presence of gravitational asymmetry. Maximum shear stresses were found to decrease exponentially with increasing Reynolds number. Vortex-induced shearing near the bifurcation is identified as a possible mechanism for endothelial cell damage.

  8. Aortoiliac morphologic correlations in aneurysms undergoing endovascular repair.

    PubMed

    Ouriel, Kenneth; Tanquilut, Eugene; Greenberg, Roy K; Walker, Esteban

    2003-08-01

    The feasibility of endovascular aneurysm repair depends on morphologic characteristics of the aortoiliac segment. Knowledge of such characteristics is relevant to safe deployment of a particular device in a single patient and to development of new devices for use in patients with a broader spectrum of anatomic variations. We evaluated findings on computed tomography scans for 277 patients being considered for endovascular aneurysm repair. Aortic neck length and angulation estimates were generated with three-dimensional trigonometry. Specific centerline points were recorded, corresponding to the aorta at the celiac axis, lowest renal artery, cranial aspect of the aneurysm sac, aortic terminus, right hypogastric artery origin, and left hypogastric origin. Aortic neck thrombus and calcium content were recorded, and neck conicity was calculated in degrees. Statistical analysis was performed with the Spearman rank correlation. Data are expressed as median and interquartile range. Median diameter of the aneurysms was 52 mm (interquartile range, 48-59 mm) in minor axis and 56 mm (interquartile range, 51-64 mm) in major axis, and median length was 88 mm (interquartile range, 74-103 mm). Median proximal aortic neck diameter was 26 mm (interquartile range, 22-29 mm), and median neck length was 30 mm (interquartile range, 18-45 mm). The common iliac arteries were similar in diameter (right artery, 16 mm [interquartile range, 13-20 mm]; left artery, 15 mm [interquartile range, 11-18 mm]) and length (right, 59 mm [interquartile range, 50-69 mm]; left, 60 mm [interquartile range, 49-70 mm]). Median angulation of the infrarenal aortic neck was 40 degrees (interquartile range, 29-51 degrees), and median angulation of the suprarenal segment was 45 degrees (interquartile range, 36-57 degrees). By gender, sac diameter, proximal neck diameter, and iliac artery diameter were significantly larger in men. Significant linear associations were identified between sac diameter and sac length, neck angulation, and iliac artery diameter. As the length of the aneurysm sac increased the proximal aortic neck length decreased. Conversely, as the sac length decreased sac eccentricity increased. Mural thrombus content within the neck increased with increasing neck diameter. There is considerable variability in aortoiliac morphologic parameters. Significant associations were found between various morphologic variables, links that are presumably related to a shared pathogenesis for aberration in aortoiliac diameter, length, and angulation. Ultimately this information can be used to develop new endovascular devices with broader applicability and improved long-term results.

  9. [An experimental study of the healing of velour grafts].

    PubMed

    Kobayashi, O

    1986-02-01

    An experimental study of implantation of velour grafts in the abdominal aorta or the external iliac artery of dogs was conducted with the object of evaluating the type of velour surface best fit for small-caliber artery implantation. Velour grafts measuring 4mm in diameter with differing velour surfaces were used as materials. Velour grafts now available on the market differ not only in velour surface but also in structure, notably in porosity and wall thickness. Hence each of the grafts used was reversed (i.e. inside out) and thus new grafts were prepared. These grafts were considered most suitable for making a comparative study of the effects of velour surface on healing. Macroscopic and histological findings revealed that each graft was good healing with the rate of patency as high as 84 percent. However, like Vasculour-D grafts, crimped grafts which preserve the crimp after implantation was significantly thicker at the internal valley than other grafts. Based on the findings of this experimental study non-crimped velour grafts were considered to be best fit for small-caliber artery implantation.

  10. [Applied anatomy of the perforating branches artery and its distally-based flap of sural nerve nutrient vessels].

    PubMed

    Zhang, Fahui; Xie, Qiyang; Zheng, Heping

    2005-07-01

    To investigate the distribution of the perforating branches artery of distally-based flap of sural nerve nutrient vessels and its clinical application. The origins and distribution of perforating branches artery of distally-based flap were observed on specimens of 30 adult cadaveric low limbs by perfusing red gelatin to dissect the artery. Among the 36 cases, there were 21 males, 15 females. Their ages ranged from 6 to 66, 35. 2 in average. The defect area was 3.5 cm x 2.5 cm to 17.0 cm x 11.0 cm. The flap taken ranged from 4 cm x 3 cm to 18 cm x 12 cm. The perforating branches artery of distally-based flap had 2 to 5 branches and originated from the heel lateral artery, the terminal perforating branches of peroneal artery (diameters were 0.6+/-0.2 mm and 0.8+/-0.2 mm, 1.0 +/- 1.3 cm and 2.8 +/- 1.0 cm to the level of cusp lateral malleolus cusp). The intermuscular septum perforating branches of peroneal artery had 0 to 3 branches. Their rate of presence was 96.7%, 66.7% and 20.0% respectively (the diameters were 0.9 +/- 0.3, 1.0 +/- 0.2 and 0.8 +/- 0.4 mm, and their distances to the level of cusp of lateral malleolus were 5.3 +/- 2.1, 6.8 +/- 2.8 and 7.0 +/- 4.0 cm). Those perforating branches included fascia branches, cutaneous branches, nerve and vein nutrient branches. Those nutrient vessels formed longitudinal vessel chain of sural nerve shaft, vessel chain of vein side and vessel network of deep superficial fascia. The distally-based superficial sural artery island flap was used in 18 cases, all flaps survived. Distally-based sural nerve, small saphenous vein, and nutrient vessels of fascia skin have the same origin. Rotation point of flap is 3.0 cm to the cusp of lateral malleolus, when the distally-based flap is pedicled with the terminal branch of peroneal artery. Rotation point of flap is close to the cusp of lateral malleolus, when the distally-based flap is pedicled with the heel lateral artery.

  11. Abnormal splenic artery diameter/hepatic artery diameter ratio in cirrhosis-induced portal hypertension

    PubMed Central

    Zeng, Dao-Bing; Dai, Chuan-Zhou; Lu, Shi-Chun; He, Ning; Wang, Wei; Li, Hong-Jun

    2013-01-01

    AIM: To determine an optimal cutoff value for abnormal splenic artery diameter/proper hepatic artery diameter (S/P) ratio in cirrhosis-induced portal hypertension. METHODS: Patients with cirrhosis and portal hypertension (n = 770) and healthy volunteers (n = 31) underwent volumetric computed tomography three-dimensional vascular reconstruction to measure the internal diameters of the splenic artery and proper hepatic artery to calculate the S/P ratio. The cutoff value for abnormal S/P ratio was determined using receiver operating characteristic curve analysis, and the prevalence of abnormal S/P ratio and associations between abnormal S/P ratio and major complications of portal hypertension were studied using logistic regression. RESULTS: The receiver operating characteristic analysis showed that the cutoff points for abnormal splenic artery internal diameter and S/P ratio were > 5.19 mm and > 1.40, respectively. The sensitivity, specificity, positive predictive value, and negative predictive value were 74.2%, 45.2%, 97.1%, and 6.6%, respectively. The prevalence of an abnormal S/P ratio in the patients with cirrhosis and portal hypertension was 83.4%. Patients with a higher S/P ratio had a lower risk of developing ascites [odds ratio (OR) = 0.708, 95%CI: 0.508-0.986, P = 0.041] and a higher risk of developing esophageal and gastric varices (OR = 1.483, 95%CI: 1.010-2.175, P = 0.044) and forming collateral circulation (OR = 1.518, 95%CI: 1.033-2.230, P = 0.034). After splenectomy, the portal venous pressure and maximum and mean portal venous flow velocities were reduced, while the flow rate and maximum and minimum flow velocities of the hepatic artery were increased (P < 0.05). CONCLUSION: The prevalence of an abnormal S/P ratio is high in patients with cirrhosis and portal hypertension, and it can be used as an important marker of splanchnic hemodynamic disturbances. PMID:23483462

  12. Angiographic predictors of 3-year patency of bypass grafts implanted on the right coronary artery system: a prospective randomized comparison of gastroepiploic artery, saphenous vein, and right internal thoracic artery grafts.

    PubMed

    Glineur, David; D'hoore, William; de Kerchove, Laurent; Noirhomme, Philippe; Price, Joel; Hanet, Claude; El Khoury, Gebrine

    2011-11-01

    Saphenous vein, in situ right gastroepiploic artery, and right internal thoracic artery grafts are routinely used to revascularize the right coronary artery. Little is known about the predictive value of objective preoperative angiographic parameters on midterm graft patency. We prospectively enrolled 210 consecutive patients undergoing coronary revascularization. Revascularization of the right coronary artery was randomly performed with the saphenous vein grafts in 81 patients and the right gastroepiploic artery in 92 patients. During the same study period, 37 patients received right coronary artery revascularization with the right internal thoracic artery used in a Y-composite fashion. All patients underwent a protocol-driven coronary angiogram 3 years after surgery. Preoperative angiographic parameters included minimum lumen diameter percent stenosis measured by quantitative angiography. A graft was considered "not functional" with patency scores of 0 to 2 and "functional" with patency scores of 3 or 4. Angiographic follow-up was 100% complete. A significant difference in the distribution of flow patterns was observed in the 3 groups. In multivariate analysis, the use of a saphenous vein graft was associated with superior graft functionality compared with the other conduits (odds ratio, 6.1; 95% confidence interval, 2.4-15). Graft function was negatively influenced by the minimum lumen diameter (odds ratio, 0.11; confidence interval, 0.05-0.25). In the right gastroepiploic artery and right internal thoracic artery groups, the proportion of functional grafts was higher when the minimum lumen diameter was below a threshold value in the third minimum lumen diameter quartile (0.64-1.30 mm). Preoperative angiography predicts graft patency in the right gastroepiploic artery and right internal thoracic artery, whereas the flow pattern in saphenous vein grafts is significantly less influenced by quantitative angiographic parameters. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  13. Impact of elastin incorporation into electrochemically aligned collagen fibers on mechanical properties and smooth muscle cell phenotype.

    PubMed

    Nguyen, Thuy-Uyen; Bashur, Chris A; Kishore, Vipuil

    2016-03-17

    Application of tissue-engineered vascular grafts (TEVGs) for the replacement of small-diameter arteries is limited due to thrombosis and intimal hyperplasia. Previous studies have attempted to address the limitations of TEVGs by developing scaffolds that mimic the composition (collagen and elastin) of native arteries to better match the mechanical properties of the graft with the native tissue. However, most existing scaffolds do not recapitulate the aligned topography of the collagen fibers found in native vessels. In the current study, based on the principles of isoelectric focusing, two different types of elastin (soluble and insoluble) were incorporated into highly oriented electrochemically aligned collagen (ELAC) fibers and the effect of elastin incorporation on the mechanical properties of the ELAC fibers and smooth muscle cell (SMC) phenotype was investigated. The results indicate that elastin incorporation significantly decreased the modulus of ELAC fibers to converge upon that of native vessels. Further, a significant increase in yield strain and decrease in Young's modulus was observed on all fibers post SMC culture compared with before the culture. Real-time polymerase chain reaction results showed a significant increase in the expression of α-smooth muscle actin and calponin on ELAC fibers with insoluble elastin, suggesting that incorporation of insoluble elastin induces a contractile phenotype in SMCs after two weeks of culture on ELAC fibers. Immunofluorescence results showed that calponin expression increased with time on all fibers. In conclusion, insoluble elastin incorporated ELAC fibers have the potential to be used for the development of functional TEVGs for the repair and replacement of small-diameter arteries.

  14. Distal end side-to-side anastomoses of sequential vein graft to small target coronary arteries improve intraoperative graft flow

    PubMed Central

    2014-01-01

    Background End-to-side anastomoses to connect the distal end of the great saphenous vein (GSV) to small target coronary arteries are commonly performed in sequential coronary artery bypass grafting (CABG). However, the oversize diameter ratio between the GSV and small target vessels at end-to-side anastomoses might induce adverse hemodynamic condition. The purpose of this study was to describe a distal end side-to-side anastomosis technique and retrospectively compare the effect of distal end side-to-side versus end-to-side anastomosis on graft flow characteristics. Methods We performed side-to-side anastomoses to connect the distal end of the GSV to small target vessels on 30 patients undergoing off-pump sequential CABG in our hospital between October 2012 and July 2013. Among the 30 patients, end-to-side anastomoses at the distal end of the GSV were initially performed on 14 patients; however, due to poor graft flow, those anastomoses were revised into side-to-side anastomoses. We retrospectively compared the intraoperative graft flow characteristics of the end-to-side versus side-to-side anastomoses in the 14 patients. The patient outcomes were also evaluated. Results We found that the side-to-side anastomosis reconstruction improved intraoperative flow and reduced pulsatility index in all the 14 patients significantly. The 16 patients who had the distal end side-to-side anastomoses performed directly also exhibited satisfactory intraoperative graft flow. Three-month postoperative outcomes for all the patients were satisfactory. Conclusions Side-to-side anastomosis at the distal end of sequential vein grafts might be a promising strategy to connect small target coronary arteries to the GSV. PMID:24884776

  15. Chitosan nanoparticle carrying small interfering RNA to platelet-derived growth factor B mRNA inhibits proliferation of smooth muscle cells in rabbit injured arteries.

    PubMed

    Xia, He; Jun, Ji; Wen-Ping, Ling; Yi-Feng, Pan; Xiao-Ling, Chen

    2013-10-01

    The purpose of this study was to elucidate the transfection of chitosan nanoparticle carrying small interfering RNA against platelet-derived growth factor B (PDGF-B) to inhibit the expression of PDGF-B mRNA and proliferation of smooth muscle cells. A rabbit iliac artery injury model was constructed. A small interfering RNA (siRNA) against PDGF-B mRNA expression vector was constructed and packaged by chitosan nanoparticle to transfect into the vascular smooth muscle cells (vSMCs) of balloon catheter-injured rabbit iliac artery wall, using a therapeutic ultrasound for the gene delivery. The experiment was divided into two groups: experimental group, denudation and nano-PDGF-B siRNA treated, and only single denudation as control. Effects of the siRNA on the expressions of proliferating cell nuclear antigen (PCNA) and PDGF-B mRNA by vSMCs and the proliferation of vSMCs were observed with the methods of routine pathological, immunohistochemical staining, in situ hybridization and morphometry. The nano siRNA against PDGF-B was successfully transfected. The nano siRNA significantly inhibited the expressions of PCNA and PDGF-B mRNA in intimal vSMCs. The local intimal thickness and area were also reduced remarkably. In conclusion, transfection of chitosan nanoparticle carrying siRNA against PDGF-B mRNA could inhibit proliferation of vSMCs in the rabbit iliac artery injury model. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  16. A Cell Culture Model of Resistance Arteries.

    PubMed

    Biwer, Lauren A; Lechauve, Christophe; Vanhoose, Sheri; Weiss, Mitchell J; Isakson, Brant E

    2017-09-08

    The myoendothelial junction (MEJ), a unique signaling microdomain in small diameter resistance arteries, exhibits localization of specific proteins and signaling processes that can control vascular tone and blood pressure. As it is a projection from either the endothelial or smooth muscle cell, and due to its small size (on average, an area of ~1 µm 2 ), the MEJ is difficult to study in isolation. However, we have developed a cell culture model called the vascular cell co-culture (VCCC) that allows for in vitro MEJ formation, endothelial cell polarization, and dissection of signaling proteins and processes in the vascular wall of resistance arteries. The VCCC has a multitude of applications and can be adapted to suit different cell types. The model consists of two cell types grown on opposite sides of a filter with 0.4 µm pores in which the in vitro MEJs can form. Here we describe how to create the VCCC via plating of cells and isolation of endothelial, MEJ, and smooth muscle fractions, which can then be used for protein isolation or activity assays. The filter with intact cell layers can be fixed, embedded, and sectioned for immunofluorescent analysis. Importantly, many of the discoveries from this model have been confirmed using intact resistance arteries, underscoring its physiological relevance.

  17. Improved aortic enhancement in CT angiography using slope-based triggering with table speed optimization: a pilot study.

    PubMed

    Bashir, Mustafa R; Weber, Paul W; Husarik, Daniela B; Howle, Laurens E; Nelson, Rendon C

    2012-08-01

    To assess whether a scan triggering technique based on the slope of the time-attenuation curve combined with table speed optimization may improve arterial enhancement in aortic CT angiography compared to conventional threshold-based triggering techniques. Measurements of arterial enhancement were performed in a physiologic flow phantom over a range of simulated cardiac outputs (2.2-8.1 L/min) using contrast media boluses of 80 and 150 mL injected at 4 mL/s. These measurements were used to construct computer models of aortic attenuation in CT angiography, using cardiac output, aortic diameter, and CT table speed as input parameters. In-plane enhancement was calculated for normal and aneurysmal aortic diameters. Calculated arterial enhancement was poor (<150 HU) along most of the scan length using the threshold-based triggering technique for low cardiac outputs and the aneurysmal aorta model. Implementation of the slope-based triggering technique with table speed optimization improved enhancement in all scenarios and yielded good- (>200 HU; 13/16 scenarios) to excellent-quality (>300 HU; 3/16 scenarios) enhancement in all cases. Slope-based triggering with table speed optimization may improve the technical quality of aortic CT angiography over conventional threshold-based techniques, and may reduce technical failures related to low cardiac output and slow flow through an aneurysmal aorta.

  18. Polyhydroxybutyrate/valerate/polycaprolactone small-diameter vascular graft: Experimental study of integration into organism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Antonova, L. V., E-mail: antonova.la@mail.ru; Burago, A. Yu.; Matveeva, V. G.

    We prepared polyhydroxybutyrate/valerate (PHBV)/polylcaprolactone (PCL) small-diameter vascular grafts using electrospinning. Surface structure was assessed by scanning electron microscopy whilst physicomechanical properties were investigated by longitudinal uniaxial tension testing. Patency of grafts implanted into the rat abdominal aorta was evaluated using a Doppler ultrasonography at 2 week, 1 month and 12 month postimplantation. In addition, we assessed local histological features, along with IL-1β, IL-2, IL-4, IL-10, TNFa, TGF-β1, and VEGF serum levels. We revealed that only 2 (25%) grafts were not thrombosed at 2 week and 1 month postimplantation. However, at 12 month postimplantation a satisfactory histological pattern was observed inmore » 50% of all cases, and we detected a monolayer of endothelial cells on the inner graft surface in half the cases. Regarding other grafts, we revealed minor connective tissue hyperplasia in 41.7% of the grafts and an inflammatory infiltrate in the part of the arterial wall in 8.3% of the grafts. We found that the IL-1β serum level was 3.5-fold higher in the group of experimental rats at 12 month postimplantation (p < 0.01). In addition, the IL-2 and IL-4 serum levels at 12 month postimplantation were 2- and 2.8-fold higher as compared to short-term implantation (2 weeks and 1 month) and control rats (p < 0.05) whilst the IL-10 serum level at 1 and 12 month postimplantation was more than 100-fold higher in comparison with 2 week postimplantation and control rats (p < 0.001). Serum VEGF was detected only at 12 month postimplantation. All in all, we created a biocompatible PHBV/PCL small-diameter vascular graft with a high surface area to volume ratio. A long-term patency of biodegradable vascular grafts after implantation into the rat abdominal aorta and the absence of a considerable immune response confirmed a high biocompatibility of such construct and the possibility of its use as a vascular graft.« less

  19. The anatomy of the superficial external pudendal artery: a quantitative study.

    PubMed

    La Falce, Osvaldir Lanzoni; Ambrosio, João Dias; Souza, Romeu Rodrigues de

    2006-10-01

    The importance of the superficial external pudendal artery in cases of lower limb obstructive arteriopathies has been established, and a perfect knowledge of its anatomy is desirable for the creation of successful flaps involving it. However, little information is available on the morphometry of this artery. In this study, we conducted a quantitative investigation of the superficial external pudendal artery as the basis for skin grafts. Twenty-five right and left sides of the inguinal region of male cadavers were dissected. After retracting the skin at the inguinal region, the femoral vessels and the sapheno-femoral junction were exposed. The following aspects were then analyzed: 1) the presence of the superficial external pudendal artery, 2) the place of origin of the superficial external pudendal artery and the common trunk, 3) the duplication of the superficial external pudendal artery, 4) the distance from the superficial external pudendal artery or the common trunk to the inguinal ligament, and 5) the diameter of the superficial external pudendal artery. The results were the following: 1) superficial external pudendal arteries were found in 46 of 50 sides (92%); 2) they originated from the femoral artery in 45 cases and from the deep femoral artery in only 1 case; 3) the arteries were found duplicated in 21 cases (46%), as a common trunk in 11 cases (24%), and as a single artery in 14 cases (30%); 4) the distance from the superficial external pudendal artery to the inguinal ligament ranged from 0.8 cm to 8.5 cm; from the common trunk, it ranged from 3.5 cm to 6.7 cm; 5) the diameter of the superficial external pudendal artery ranged from 1.2 mm to 3.8 mm; and 6) the diameter of the common trunk ranged from 1.35 mm to 5.15 mm. The results show that the superficial external pudendal artery generally originates from the femoral artery. It was found as a common trunk, duplicated, or as a single artery. There was a great variability in both the diameter of the artery and the distance from the artery to the inguinal ligament. Most of the data showed no significant differences between the right and the left sides.

  20. Promotion of artery occlusion in dogs by percutaneous rotational atherectomy.

    PubMed

    Hou, Chuan-Ju; Zhang, Duan-Zhen; Wang, Qi-Guang; Cui, Chun-Sheng; Kuang, Li; Chen, Bing; Wang, Yang

    2014-07-01

    This study aims to offer experimental data and indirect evidences for the application of percutaneous rotational atherectomy to treat patent ductus arteriosus (PDA). Eleven dogs (6 male dogs and 5 female dogs; aged 14-20 months, with an average of 16.7±3.2 months; weight 20-25 kg, with an average of 22.7±2.5 kg) were enrolled in this study. The diameters of the left and right arteries ranged from 3.2 to 4.8 mm (average 3.9±0.6 mm) on percutaneous angiography. Percutaneous rotational atherectomy with proper rotablator (the size was 1-1.5 mm larger than the artery diameter) was performed in the arterial intima. After 4 weeks from percutaneous rotational atherectomy, arteriography was conducted to observe the changes in artery diameter. Then all dogs were sacrificed and the pathologic examination was conducted on the left and right axillary arteries. There were obvious changes with different degrees in 22 arteries, including 8 arteries with complete occlusion and 12 arteries with stenosis (≥2/3, 1/2, and 1/3 stenosis in 4, 4, and 4 arteries, respectively). The occlusion rate was 36.4% and the total effective rate was 90.9%. It was considered failure in other 2 arteries with <1/3 of stenosis. Percutaneous rotational atherectomy of arterial intima can promote the occlusion of arteries. This has provided a new choice for the treatment of PDA. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. A Novel Ex Vivo Training Model for Acquiring Supermicrosurgical Skills Using a Chicken Leg.

    PubMed

    Cifuentes, Ignacio J; Rodriguez, José R; Yañez, Ricardo A; Salisbury, María C; Cuadra, Álvaro J; Varas, Julian E; Dagnino, Bruno L

    2016-11-01

    Background  Supermicrosurgery is a technique used for dissection and anastomosis of submillimeter diameter vessels. This technique requires precise hand movements and superb eye-hand coordination, making continuous training necessary. Biological in vivo and ex vivo models have been described for this purpose, the latter being more accessible and cost-effective. The aim of this study is to present a new ex vivo training model using a chicken leg. Methods  In 28 chicken legs, an anatomical study was performed. An intramuscular perforator vessel was identified and dissected. Arterial diameters of 0.7, 0.5, and 0.3 mm were identified and consistency of the perforator was assessed. In additional 10 chicken legs, 25 submillimeter arteries were anastomosed using this perforator vessel. Five arteries of 0.3 and 10 of 0.5 mm were anastomosed with nylon 11-0 and 12-0 sutures. Intravascular stent (IVaS) technique and open guide (OG) technique were used in 0.5-mm arteries. A total of 10 arteries of 0.7 mm were anastomosed using 10-0 sutures in a conventional fashion. Dissection and anastomosis time were recorded and patency was tested. Results  We were able to identify 0.7 to 0.3 mm diameter arteries in all the specimens and confirm the consistency of the perforator. The median time for dissection was 13.4 minutes. The median time for anastomosis was 32.3 minutes for 0.3-mm arteries, 24.3 minutes for 0.5-mm arteries using IVaS, 29.5 minutes for the OG technique, and 20.9 minutes for the 0.7 mm diameter arteries. All the anastomoses were permeable. Conclusion  Due to its consistent and adequate diameter vessels, this model is adequate for training supermicrosurgical skills. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  2. Gradient changes in porcine renal arterial vascular anatomy and blood flow after cryoablation.

    PubMed

    Lagerveld, Brunolf W; van Horssen, Pepijn; Laguna, M Pilar; van den Wijngaard, Jeroen P H M; Siebes, Maria; Wijkstra, Hessel; de la Rosette, Jean J M C H; Spaan, Jos A E

    2011-08-01

    We quantified temporal changes in vascular structure and blood flow after cryosurgery of the porcine kidney in vivo. We studied 5 groups of 4 kidneys each with a survival time of 20 minutes, 4 hours, 2 days, and 1 and 2 weeks after cryoablation, respectively. Before harvesting the kidneys, fluorescently labeled microspheres were administrated in the descending aorta. After harvest the kidney and its vasculature were casted with fluorescently dyed elastomer, frozen and processed in an imaging cryomicrotome to reveal the 3-dimensional arterial branching structure and microsphere distribution. In regions of interest vessels were segmented by image analysis software and histograms were constructed to reveal the total summed vessel length as a function of diameter. A characteristic diameter of the ablated area was measured. The 20-minute survival group histograms showed a significant shift of the peak to larger diameters (p<0.002), indicating that smaller vessels were destroyed. Microsphere density was decreased to 2% in the ablated region but not in the nonablated border zone, depending on the remaining crater crossing larger vessels. After 2 weeks neither vessels nor microspheres were left in the ablated area, which had shrunk by about 40% in diameter. Study limitations are the lack of histological confirmation and the use of normal rather than cancerous tissue. Larger vessels remain patent just after ablation and transport blood to the border of the ablation crater but perfusion within the crater is halted instantly. Characteristic crater diameter increases initially but decreases thereafter. Destruction of vessels and tissue is complete 2 weeks after cryoablation. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  3. Automated measurement and classification of pulmonary blood-flow velocity patterns using phase-contrast MRI and correlation analysis.

    PubMed

    van Amerom, Joshua F P; Kellenberger, Christian J; Yoo, Shi-Joon; Macgowan, Christopher K

    2009-01-01

    An automated method was evaluated to detect blood flow in small pulmonary arteries and classify each as artery or vein, based on a temporal correlation analysis of their blood-flow velocity patterns. The method was evaluated using velocity-sensitive phase-contrast magnetic resonance data collected in vitro with a pulsatile flow phantom and in vivo in 11 human volunteers. The accuracy of the method was validated in vitro, which showed relative velocity errors of 12% at low spatial resolution (four voxels per diameter), but was reduced to 5% at increased spatial resolution (16 voxels per diameter). The performance of the method was evaluated in vivo according to its reproducibility and agreement with manual velocity measurements by an experienced radiologist. In all volunteers, the correlation analysis was able to detect and segment peripheral pulmonary vessels and distinguish arterial from venous velocity patterns. The intrasubject variability of repeated measurements was approximately 10% of peak velocity, or 2.8 cm/s root-mean-variance, demonstrating the high reproducibility of the method. Excellent agreement was obtained between the correlation analysis and radiologist measurements of pulmonary velocities, with a correlation of R2=0.98 (P<.001) and a slope of 0.99+/-0.01.

  4. Multidetector computed tomography shows reverse cardiac remodeling after double lung transplantation for pulmonary hypertension.

    PubMed

    Mandich Crovetto, D; Alonso Charterina, S; Jiménez López-Guarch, C; Pont Vilalta, M; Pérez Núñez, M; de Pablo Gafas, A; Escribano Subías, P

    2016-01-01

    To use multidetector computed tomography (MDCT) to evaluate the structural changes in the right heart and pulmonary arteries that occur in patients with severe pulmonary hypertension treated by double lung transplantation. This was a retrospective study of 21 consecutive patients diagnosed with severe pulmonary hypertension who underwent double lung transplantation at our center between 2010 and 2014. We analyzed the last MDCT study done before lung transplantation and the first MDCT study done after lung transplantation. We recorded the following variables: diameter of the pulmonary artery trunk, ratio of the diameter of the pulmonary artery trunk to the diameter of the ascending aorta, diameter of the right ventricle, ratio of the diameter of the left ventricle to the diameter of the right ventricle, and eccentricity index. Statistical analysis consisted of the comparison of the means of the variables recorded. In all cases analyzed, the MDCT study done a mean of 24±14 days after double lung transplantation showed a significant reduction in the size of the right heart chambers, with improved indices of ventricular interdependency index, and reduction in the size of the pulmonary artery trunk (p<0.001 for all the variables analyzed). Patients with pulmonary hypertension treated by double lung transplantation present early reverse remodeling of the changes in the structures of the right heart and pulmonary arterial tree. MDCT is useful for detecting these changes. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  5. Measurements of the pulmonary vasculature on thoracic radiographs in healthy dogs compared to dogs with mitral regurgitation.

    PubMed

    Oui, Heejin; Oh, Juyeon; Keh, Seoyeon; Lee, Gahyun; Jeon, Sunghoon; Kim, Hyunwook; Yoon, Junghee; Choi, Jihye

    2015-01-01

    This study reassessed the previously reported radiographic method of comparing pulmonary vessels versus rib diameter for differentiating healthy dogs and dogs with mitral regurgitation. The width of the right cranial pulmonary artery and vein at the fourth rib level, right caudal pulmonary artery and vein at the ninth rib level, and the diameters of the fourth rib and ninth rib were measured in prospectively recruited healthy dogs (n = 40) and retrospectively recruited dogs with mitral regurgitation (n = 58). In healthy dogs, the pulmonary arteries and accompanying veins were similar in size. The cranial lobar vessels were smaller than the fourth rib. However, 67.5% of right caudal pulmonary artery diameters and 65% of vein diameters were larger than the ninth rib in healthy dogs. The right caudal pulmonary vein diameter in dogs with mitral regurgitation, particularly those within moderate and severe grades, was significantly larger than that in healthy dogs (P < 0.001). The comparative method used to detect enlargement of the right caudal pulmonary vein relative to the accompanying pulmonary artery had the highest sensitivity (80.2%) and specificity (82.5%) for predicting mitral regurgitation. A cut-off of 1.22 when applying the ninth rib criterion had better specificity (73%) than the most used value ≤ 1 (89.7% sensitivity and 63.8% specificity), although it has less sensitivity (73%). We recommend using the accompanying pulmonary artery and 1.22 × the diameter of the ninth rib as a radiographic criterion for assessing the size of the right caudal pulmonary vein and differentiating healthy dogs from those with mitral regurgitation. © 2014 American College of Veterinary Radiology.

  6. Scaling of Myocardial Mass to Flow and Morphometry of Coronary Arteries

    PubMed Central

    Choy, Jenny Susana; Kassab, Ghassan S.

    2009-01-01

    There is no doubt that scaling relations exist between myocardial mass and morphometry of coronary vasculature. The purpose of this study is to quantify several morphological (diameter, length, and volume) and functional (flow) parameters of the coronary arterial tree in relation to myocardial mass. Eight normal porcine hearts of 117-244 g (mean of 177.5±32.7) were used in this study. Various coronary sub-trees of the Left Anterior Descending (LAD), Right Coronary (RCA) and Left Circumflex (LCX) arteries were perfused at pressure of 100 mmHg with different colors of a polymer (Microfil) in order to obtain rubber casts of arterial trees corresponding to different regions of myocardial mass. Volume, diameter and cumulative length of coronary arteries were reconstructed from casts to analyze their relationship to the perfused myocardial mass. Volumetric flow was measured in relationship with perfused myocardial mass. Our results show that arterial volume is linearly related to regional myocardial mass, whereas the sum of coronary arterial branch lengths, vessel diameters and volumetric flow show an approximately 3/4, 3/8 and 3/4 power-law relationship, respectively, in relation to myocardial mass. These scaling laws suggest fundamental design principles underlying the structure-function relationship of the coronary arterial tree that may facilitate diagnosis and management of diffuse coronary artery disease. PMID:18323461

  7. Scaling of myocardial mass to flow and morphometry of coronary arteries.

    PubMed

    Choy, Jenny Susana; Kassab, Ghassan S

    2008-05-01

    There is no doubt that scaling relations exist between myocardial mass and morphometry of coronary vasculature. The purpose of this study is to quantify several morphological (diameter, length, and volume) and functional (flow) parameters of the coronary arterial tree in relation to myocardial mass. Eight normal porcine hearts of 117-244 g (mean of 177.5 +/- 32.7) were used in this study. Various coronary subtrees of the left anterior descending, right coronary, and left circumflex arteries were perfused at pressure of 100 mmHg with different colors of a polymer (Microfil) to obtain rubber casts of arterial trees corresponding to different regions of myocardial mass. Volume, diameter, and cumulative length of coronary arteries were reconstructed from casts to analyze their relationship to the perfused myocardial mass. Volumetric flow was measured in relationship with perfused myocardial mass. Our results show that arterial volume is linearly related to regional myocardial mass, whereas the sum of coronary arterial branch lengths, vessel diameters, and volumetric flow show an approximately 3/4, 3/8, and 3/4 power-law relationship, respectively, in relation to myocardial mass. These scaling laws suggest fundamental design principles underlying the structure-function relationship of the coronary arterial tree that may facilitate diagnosis and management of diffuse coronary artery disease.

  8. Intermittent, moderate-intensity aerobic exercise for only eight weeks reduces arterial stiffness: evaluation by measurement of stiffness parameter and pressure-strain elastic modulus by use of ultrasonic echo tracking.

    PubMed

    Tanaka, Midori; Sugawara, Motoaki; Ogasawara, Yasuo; Izumi, Tadafumi; Niki, Kiyomi; Kajiya, Fumihiko

    2013-04-01

    Aerobic exercise has been reported to be associated with reduced arterial stiffness. However, the intensity, duration, and frequency of aerobic exercise required to improve arterial stiffness have not been established. In addition, most reports base their conclusions on changes in pulse wave velocity, which is an indirect index of arterial stiffness. We studied the effects of short-term, intermittent, moderate-intensity exercise training on arterial stiffness based on measurements of the stiffness parameter (β) and pressure-strain elastic modulus (E p), which are direct indices of regional arterial stiffness. A total of 25 young healthy volunteers (18 men) were recruited. By use of ultrasonic diagnostic equipment we measured β and E p of the carotid artery before and after 8 weeks of exercise training. After exercise training, systolic pressure (P s), diastolic pressure (P d), pulse pressure, systolic arterial diameter (D s), and diastolic arterial diameter (D d) did not change significantly. However, the pulsatile change in diameter ((D s - D d)/D d) increased significantly, and β and E p decreased significantly. For healthy young subjects, β and E p were reduced by intermittent, moderate-intensity exercise training for only 8 weeks.

  9. Experimental and clinical studies on transmyocardial laser revascularzation (TMLR)

    NASA Astrophysics Data System (ADS)

    Okada, Masayoshi

    2005-07-01

    The number of patients with coronary artery disease has been increasing in Japan and several kinds of treatments have been performed to reduce their cardiovascular diseases. In patients with small branches, or diffuse stenotic lesions of the coronary arteries, on whom coronary artery bypass grafting(CABG) and percutaneous coronary intervention (PCI) cannot be carried out, it has been hemodynamically demonstrated possible to supply arterial blood from the left ventricular cavity to the ischemic myocardium through laser channels. On the basis of excellent experimental studies using mongrel dogs, newly created laser channels 0.2 mm in diameter have been confirmed to be histologically patent even 3 years after transmyocardial revascularization(TMLR). Thus, this method could be applied as an alternative procedure of transmyocardial revascularization. First clinical procedure of TMLR alone was performed on 55 year-old male patient with severe angina pectoris who had undergone pericardiectomy 7 years ago. He had no candidate for percutaneous coronary intervention, or coronary artery bypass grafting, because his left venticle had severe adhesion to the left lung. Therefore, this method was finally carried out. He is getting well after this surgical intervention. This procedure should be recommended for the patient with end-stage coronary artery disease.

  10. Intraspecific scaling laws of vascular trees.

    PubMed

    Huo, Yunlong; Kassab, Ghassan S

    2012-01-07

    A fundamental physics-based derivation of intraspecific scaling laws of vascular trees has not been previously realized. Here, we provide such a theoretical derivation for the volume-diameter and flow-length scaling laws of intraspecific vascular trees. In conjunction with the minimum energy hypothesis, this formulation also results in diameter-length, flow-diameter and flow-volume scaling laws. The intraspecific scaling predicts the volume-diameter power relation with a theoretical exponent of 3, which is validated by the experimental measurements for the three major coronary arterial trees in swine (where a least-squares fit of these measurements has exponents of 2.96, 3 and 2.98 for the left anterior descending artery, left circumflex artery and right coronary artery trees, respectively). This scaling law as well as others agrees very well with the measured morphometric data of vascular trees in various other organs and species. This study is fundamental to the understanding of morphological and haemodynamic features in a biological vascular tree and has implications for vascular disease.

  11. Independent Suture Tape Reinforcement of Small and Standard Diameter Grafts for Anterior Cruciate Ligament Reconstruction: A Biomechanical Full Construct Model.

    PubMed

    Bachmaier, Samuel; Smith, Patrick A; Bley, Jordan; Wijdicks, Coen A

    2018-02-01

    To compare the dynamic elongation, stiffness behavior, and ultimate failure load of standard with small diameter soft tissue grafts for anterior cruciate ligament (ACL) reconstruction with and without high-strength suture tape reinforcement. Both a tripled "small" diameter and a "standard" quadrupled tendon graft with and without suture tape reinforcement were tested using suspensory fixation (n = 8 each group). The suture tape was passed through the suspensory fixation button on the femur and tibia to ensure independent (safety belt) fixation from the graft in vitro. The testing of the constructs included position-controlled cyclic loading, force-controlled cyclic loading at 250 N and 400 N as well as pull to failure (50 mm/min). Reinforcement of a small diameter graft significantly reduced dynamic elongation of 38% (1.46 ± 0.28 mm vs 2.34 ± 0.44 mm, P < .001) and 50% (2.55 ± 0.44 mm vs 5.06 ± 0.67 mm, P < .001) after the 250 N and 400 N load protocol, respectively. Reinforcement of a standard diameter tendon graft decreased dynamic elongation of 15% (1.59 ± 0.34 mm vs 1.86 ± 0.17 mm, P = .066) and 26% (2.62 ± 0.44 mm vs 3.55 ± 0.44 mm, P < .001). No significant difference was found between both reinforced models. The ultimate failure loads of small and standard diameter reinforced grafts were 1592 ± 105 N and 1585 ± 265 N, resulting in a 64% (P < .001) and 40% (P < .001) increase compared with their respective controls. Independent suture tape reinforcement of soft tissue grafts for ACL reconstruction leads to significantly reduced elongation and higher ultimate failure load according to in vivo native ACL function data without stress-shielding the soft tissue graft. If in vitro results are translational to human knees in vivo, the suture tape reinforcement technique for ACL reconstruction may decrease the risk of graft tears, particularly in the case of small diameter soft tissue grafts. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  12. Diameter of fluorescent microspheres determines their distribution throughout the cortical watershed area in mice.

    PubMed

    Tsukada, Naoki; Katsumata, Masahiro; Oki, Koichi; Minami, Kazushi; Abe, Takato; Takahashi, Shinichi; Itoh, Yoshiaki; Suzuki, Norihiro

    2018-01-15

    A hemodynamic mechanism has long been assumed to play an important role in watershed infarction. In recent years, however, clinical evidence has indicated that an embolic mechanism is involved. The mechanism by which emboli are trapped preferentially in watershed areas remains unclear. In the present study, we developed a mouse embolus model using fluorescent microspheres with different diameters and evaluated the role of the microspheres' diameters in the generation of a watershed-patterned distribution. We injected fluorescent microspheres of four different diameters (i.e., 13, 24, 40, and 69 μm) into the internal carotid artery of C57BL/6 mice either (1) without ligation of the common carotid artery (normal perfusion pressure model: NPPM) or (2) with ligation of the common carotid artery (low perfusion pressure model: LPPM). Left common carotid artery ligation induced reductions in local cerebral blood flow in both the periphery and the core area of the left middle cerebral artery. A greater reduction in the border-zone area between the left anterior cerebral artery and the middle cerebral artery was also noted. After 24 h, the brains were removed and the distribution of the microspheres in the brain was evaluated using a fluorescence microscope. The 24-μm microspheres were distributed in the watershed area more frequently than the other microsphere sizes (P < .05, ANOVA followed by Tukey's test). Meanwhile, the distribution rates were similar between the NPPM and LPPM models for all microsphere sizes. This study suggested that the distribution pattern of the microspheres was only affected by the microspheres' diameters. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Correlations of serum cystatin C and hs-CRP with vascular endothelial cell injury in patients with active systemic lupus erythematosus.

    PubMed

    Gao, Dong; Shao, Juan; Jin, Waishu; Xia, Xiujuan; Qu, Yan

    2018-05-22

    To investigate the correlations of serum cystatin C and high-sensitivity C-reactive protein (hs-CRP) with vascular endothelial cell injury in patients with active systemic lupus erythematosus (SLE). A total of 80 patients with SLE treated in our hospital from January 2016 to September 2017 were selected and randomly divided into stable-stage group (n=40) and active-stage group (n=40) using a random number table. The expressions of cystatin C and hs-CRPin stable and active stages were compared, and the inner diameters of brachial artery and levels of vascular endothelial growth factors in stable and active stages were also compared.The correlationsof expressions of cystatin C and hs-CRP in active stage with the inner diameter of brachial artery and vascular endothelial growth factor were analyzed. At the same time, the correlation between vascular endothelial growth factor and inner diameter of brachial artery in active stage was analyzed. The level of cystatin C in active stage was higher than that in stable stage (P<0.05), and the expression level of hs-CRP in active stage was also higher than that in stable stage (P<0.05). The inner diameter of brachial artery in active stage was smaller than that in stable stage (P<0.05), butthe level of vascular endothelial growth factor was higher than that in stable stage (P<0.05). The expressions of cystatin C and hs-CRP were negatively correlated with the inner diameter of brachial artery in active stage (P<0.05). The expressions of cystatin C and hs-CRP were positively correlated with vascular endothelial growth factor in active stage (P<0.05). Moreover, there was a negative correlation between vascular endothelial growth factor and inner diameter of brachial artery in active stage (P<0.05). Levels of cystatin C and hs-CRP are significantly increased in patients with active SLE, and the increase degrees are negatively correlated with the inner diameter of brachial artery under ultrasound, but positively correlated with the level of vascular endothelial growth factor in vivo.

  14. Transverse Cervical Artery: Consistent Anatomical Landmarks and Clinical Experience with Its Use as a Recipient Artery in Complex Head and Neck Reconstruction.

    PubMed

    Tessler, Oren; Gilardino, Mirko S; Bartow, Matthew J; St Hilaire, Hugo; Womac, Daniel; Dionisopoulos, Tassos; Lessard, Lucie

    2017-03-01

    Many head and neck reconstructions occur in patients with extensive history of surgery or radiation treatment. This leads to complicated free flap reconstructions, especially in choosing recipient vessels in a "frozen neck." The transverse cervical artery is an optimal second-line recipient artery in head and neck reconstruction. Seventy-two neck sides in 36 cadavers were dissected, looking for the transverse cervical artery and transverse cervical vein. Anatomical location of these vessels, their diameter, and length were documented. A retrospective analysis on 19 patients who had head and neck reconstruction using the transverse cervical artery as a recipient artery was undertaken as well with regard to outcome of procedures, reason for surgery, previous operations, and use of vein grafts during surgery. The transverse cervical artery was present in 72 of 72 of cadaveric specimens, and was infraclavicular in two of 72 specimens. Transverse cervical artery length ranged from 4.0 to 7.0 cm, and the mean diameter was 2.65 mm. The transverse cervical vein was present in 61 of 72 cadaveric specimens, the length ranged from 4.0 to 7.0 cm, and the mean diameter was 2.90 mm. The transverse cervical artery averaged 33 mm from midline, and branched off the thyrocervical trunk at an average 17 mm superior to the clavicle. Transverse cervical artery stenosis was markedly less in comparison with external carotid artery stenosis. In a 20-year clinical follow-up study, the transverse cervical artery was the recipient artery in 19 patients. A vein graft was used in one patient, and no flap loss occurred in any of the 19 patients. The transverse cervical artery is a reliable and robust option as a recipient artery in free flap head and neck reconstruction.

  15. Rabbit hepatic arterial anatomy variations: implications on experimental design.

    PubMed

    Tam, Alda L; Melancon, Marites P; Ensor, Joe; Liu, Yang; Dixon, Katherine; McWatters, Amanda; Gupta, Sanjay

    2014-12-01

    The VX2 rabbit model of liver cancer is commonly used to evaluate the efficacy of locoregional anticancer therapy and knowledge of the hepatic arterial anatomy in the rabbit is important for catheter-directed experiments. To describe the normal anatomy and anatomic variations of the celiac axis and hepatic artery in the rabbit. Angiograms of 222 rabbits were retrospectively reviewed. The branching pattern of the celiac axis was classified and the diameters of the major branches were measured. Paired t-tests were used to compare the difference between the average sizes of arteries. Variant celiac axis or hepatic artery anatomy was noted in 25.9% of angiograms, with the gastric branches arising from the proper hepatic artery in 23.3% of cases. The celiac axis could be successfully classified into one of five distinct branching patterns in 193 (86.9%) cases. The mean diameters of the right and left hepatic arteries were 0.67 mm (95% CI [0.64, 0.7]) and 1.25 mm (95% CI [1.19, 1.31]), respectively. The mean diameters of the medial and lateral branches of the left hepatic artery were 0.63 mm (95% CI [0.6, 0.67]) and 0.91 mm (95% CI [0.86, 0.96]), respectively. The right hepatic artery was significantly smaller than the left hepatic artery and the lateral branch of the left hepatic artery (all P values <0.0001). Arterial variants in the rabbit are not uncommon. The proper hepatic artery often gives origin to gastric artery branches. To facilitate superselective intra-arterial intervention, the left lateral lobe of the liver should be targeted for tumor implantation because of the significant size difference between the right and left hepatic arteries. © The Foundation Acta Radiologica 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  16. Biocompatibility, Inflammatory Response, and Recannalization Characteristics of Nonradioactive Resin Microspheres: Histological Findings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bilbao, Jose I., E-mail: Jibilbao@unav.e; Martino, Alba de; Luis, Esther de

    2009-07-15

    Intra-arterial radiotherapy with yttrium-90 microspheres (radioembolization) is a therapeutic procedure exclusively applied to the liver that allows the direct delivery of high-dose radiation to liver tumors, by means of endovascular catheters, selectively placed within the tumor vasculature. The aim of the study was to describe the distribution of spheres within the precapillaries, inflammatory response, and recannalization characteristics after embolization with nonradioactive resin microspheres in the kidney and liver. We performed a partial embolization of the liver and kidney vessels in nine white pigs. The left renal and left hepatic arteries were catheterized and filled with nonradioactive resin microspheres. Embolization wasmore » defined as the initiation of near-stasis of blood flow, rather than total occlusion of the vessels. The hepatic circulation was not isolated so that the effects of reflux of microspheres into stomach could be observed. Animals were sacrificed at 48 h, 4 weeks, and 8 weeks, and tissue samples from the kidney, liver, lung, and stomach evaluated. Microscopic evaluation revealed clusters of 10-30 microspheres (15-30 {mu}m in diameter) in the small vessels of the kidney (the arciform arteries, vasa recti, and glomerular afferent vessels) and liver. Aggregates were associated with focal ischemia and mild vascular wall damage. Occlusion of the small vessels was associated with a mild perivascular inflammatory reaction. After filling of the left hepatic artery with microspheres, there was some evidence of arteriovenous shunting into the lungs, and one case of cholecystitis and one case of marked gastritis and ulceration at the site of arterial occlusion due to the presence of clusters of microspheres. Beyond 48 h, microspheres were progressively integrated into the vascular wall by phagocytosis and the lumen recannalized. Eight-week evaluation found that the perivascular inflammatory reaction was mild. Liver cell damage, bile duct injury, and portal space fibrosis were not observed. In conclusion, resin microspheres (15-30 {mu}m diameter) trigger virtually no inflammatory response in target tissues (liver and kidney). Clusters rather than individual microspheres were associated with a mild to moderate perivascular inflammatory reaction. There was no evidence of either a prolonged inflammatory reaction or fibrosis in the liver parenchyma following recannalization.« less

  17. Vertebrobasilar ectasia in patients with lacunar stroke: the secondary prevention of small subcortical strokes trial.

    PubMed

    Nakajima, Makoto; Pearce, Lesly A; Ohara, Nobuyuki; Field, Thalia S; Bazan, Carlos; Anderson, David C; Hart, Robert G; Benavente, Oscar R

    2015-05-01

    The clinical implications of vertebrobasilar ectasia (VBE) in patients with cerebral small-artery disease are not well defined. We investigated whether VBE is associated with recurrent stroke, major hemorrhage, and death in a large cohort of patients with recent lacunar stroke. Maximum diameters of the vertebral and basilar arteries were measured by magnetic resonance angiography and computed tomographic angiography in 2621 participants in the Secondary Prevention of Small Subcortical Strokes trial. VBE was defined a priori as basilar artery greater than 4.5 mm and/or vertebral artery greater than 4.0 mm. Patient characteristics and risks of stroke recurrence and mortality during follow-up (median, 3.5 years) were compared between patients with and without VBE. VBE affecting 1 or more arteries was present in 200 (7.6%) patients. Patient features independently associated with VBE were increasing age, male sex, white race ethnicity, hypertension, and higher baseline diastolic blood pressure. Baseline systolic blood pressure was inversely associated with VBE. After adjustment for other risk factors, VBE was not predictive of recurrent stroke (hazard ratio [HR], 1.3; 95% confidence interval [CI], .85-1.9) or major hemorrhage (HR, 1.5; CI, .94-2.6), but was of death (HR, 1.7; CI, 1.1-2.7). In this large well-characterized cohort of patients with recent lacunar stroke, VBE was predictive of death but not of recurrent stroke or major hemorrhage. In these exploratory analyses, the frequency of VBE was directly related to diastolic blood pressure but inversely related to systolic blood pressure. Copyright © 2015 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  18. Adjustable fetal phantom for pulse oximetry

    NASA Astrophysics Data System (ADS)

    Stubán, Norbert; Niwayama, Masatsugu

    2009-05-01

    As the measuring head of a fetal pulse oximeter must be attached to the head of the fetus inside the mother's uterus during labor, testing, and developing of fetal pulse oximeters in real environment have several difficulties. A fetal phantom could enable evaluation of pulse oximeters in a simulated environment without the restrictions and difficultness of medical experiments in the labor room. Based on anatomic data we developed an adjustable fetal head phantom with three different tissue layers and artificial arteries. The phantom consisted of two arteries with an inner diameter of 0.2 and 0.4 mm. An electronically controlled pump produced pulse waves in the arteries. With the phantom we investigated the sensitivity of a custom-designed wireless pulse oximeter at different pulsation intensity and artery diameters. The results showed that the oximeter was capable of identifying 4% and 2% changes in diameter between the diastolic and systolic point in arteries of over 0.2 and 0.4 mm inner diameter, respectively. As the structure of the phantom is based on reported anatomic values, the results predict that the investigated custom-designed wireless pulse oximeter has sufficient sensitivity to detect the pulse waves and to calculate the R rate on the fetal head.

  19. The right intercostobronchial trunk: anatomical study in respect of posterior intercostal artery origin and its clinical application.

    PubMed

    Kocbek, Lidija; Rakuša, Mateja

    2018-01-01

    The right bronchial artery usually arises from the descending thoracic aorta as a common trunk with the right intercostal artery and forms the right intercostobronchial trunk. Both, the third right posterior intercostal artery and the right intercostobronchial trunk, are described as the most constant vessels. The focus of the study was to determine the characteristics of the right intercostobronchial trunk regarding the origins of the posterior intercostal arteries from the thoracic aorta. Posterior intercostal arteries and the right bronchial arteries were dissected in 43 human cadavers, preserved after Thiel's embalming method with intraarterial infusion of red colored latex. Postmortem examination gave valued information on the right intercostobronchial trunk present in 58% of cases. The right intercostobronchial trunk was mapped and new classification regarding the origin of the posterior intercostal arteries from the thoracic aorta suggested type A, B and C, the latter ones into subtypes 1 and 2. Type A was proportional to the origin level of the PIA and its corresponding intercostal space. Size of outer diameter at the origin did not indicate the right bronchial artery branch. In subtype 2 of type B the proximal posterior intercostal artery diameter that gave off right bronchial artery was thicker than distal one. The right bronchial artery originates from the second to the fifth posterior intercostal artery forming the right intercostobronchial trunk. Various origin and types of origin, diameter and course of the right intercostobronchial trunk described and analyzed in the study offer valuable information on the procedures involving the right intercostobronchial trunk.

  20. The Occurrence Rate and Diameter of Arteries Traveling Near the Mandible and an Assessment of the Relative Hemorrhage Risk in Implant Surgery.

    PubMed

    Katsumi, Yuji; Takagi, Ritsuo; Ohshima, Hayato

    2016-10-01

    Bleeding in the floor of the mouth during implant surgery is attributed to arterial injuries in the sublingual space. This study aimed to assess the relative hemorrhage risk during implant surgery. We investigated the occurrence rate and diameter of submental and sublingual arteries with special reference to their relationship with the course patterns of these arteries using 26 human cadavers. Three types of arteries were distinguished: main duct (MD), mucoperiosteal branches (MB), and cortical branches (CB). The occurrence rate of MB and CB was significantly high at the central incisor region in the upper part of the mylohyoid muscle, whereas the diameter of the MB and CB was significantly smaller than the occurrence rate of MD at the incisor regions. The occurrence rate of MD in the submental artery was significantly higher at the lateral incisor, canine, and premolar regions in the lower parts, whereas the occurrence rate of MD was significantly lower at the second and third molars in the upper parts. The susceptibility of the submental artery to injury is suggested at the incisors, canine, premolars, and first molar regions during implant surgery. © 2015 Wiley Periodicals, Inc.

  1. Normal renal arterial anatomy assessed by multidetector CT angiography: are there differences between men and women?

    PubMed

    Turba, Ulku Cenk; Uflacker, Renan; Bozlar, Ugur; Hagspiel, Klaus D

    2009-03-01

    The purpose of this study was to determine renal arterial anatomy and gender differences in adults without renovascular disease using multidetector computed tomography angiography (MDCTA). MDCTA datasets of 399 patients were retrospectively reviewed. Measurements of the aortorenal diameters, the angulation of the renal ostia and pedicles as well as the distance between the origins of the renal arteries were measured. Differences in measurements between genders were tested for statistical significance using analysis of variance (ANOVA) and Pearson's Chi-Square tests. A total of 798 renal arteries were available for analysis in 207 female (mean age = 52.91 years) and 192 male patients (mean age = 53.04 years). Female patients were found to have smaller aortae (at the level of the right renal ostium) and bilateral renal arteries than males (mean aortic diameter M/F = 18.33/15.89 mm, mean right renal artery ostial diameter M/F = 5.06/4.59 mm, mean left ostial renal diameter M/F = 5.14/4.66 mm) (p < .001). There was no statistical significance for the renal ostia level in relation to the vertebrae and the majority of renal arteries originated at the L1 and L2 levels. The longitudinal distance between right and left renal artery ostia ranged from 0 to 32 mm (mean = 4,6 mm, median = 5mm). The mean anteroposterior orientation of the right renal ostia was M/F = 29.45 degrees/28.20 degrees , and M/F = -7.96 degrees/-11.14 degrees for left renal artery ostia. The mean anteroposterior orientation of the right renal pedicle was M/F = 41.37 degrees/44.34 degrees and M/F = 42.31 degrees/43.95 degrees for the left pedicle. There are some differences in normal renal arterial anatomy between genders. Normal renal arterial information is useful not only for planning and performing of endovascular and laparoscopic urologic procedures, but also for medical device development. Copyright 2009 Wiley-Liss, Inc.

  2. A Secure and High-Fidelity Live Animal Model for Off-Pump Coronary Bypass Surgery Training.

    PubMed

    Liu, Xiaopeng; Yang, Yan; Meng, Qiang; Sun, Jiakang; Luo, Fuliang; Cui, Yongchun; Zhang, Hong; Zhang, Dong; Tang, Yue

    2016-01-01

    Existing simulators for off-pump coronary artery (CA) bypass grafting training are unable to provide cardiac surgery residents all necessary skills they need entering the operation room. In this study, we introduced a secure and high-fidelity live animal model to supplement the in vitro simulators for off-pump CA bypass grafting training. The left internal thoracic artery (ITA) of 3 Chinese miniature pigs was grafted to the left anterior descending CA using an end-to-side anastomosis. The free segment of the ITA was fixed on the ventricle surface, making it a simulative CA beating in synchrony with the heart. A total of 6 to 8 training anastomoses were made on each ITA. Animal Experiment Center in Fuwai Hospital. In total, 19 resident surgeons with at least 3 years of cardiac surgery work experience were trained using the new model. Their performances were recorded and reviewed. Simulative coronary arteries were successfully constructed in all 3 animals with no adverse event observed. A total of 19 anastomoses were then completed, 1 pig of 7 anastomoses and the other 2 animals of 6 anastomoses. Time consumption for the anastomosis was 782 ± 107 seconds. Anastomotic leakage was observed in 10/19 procedures. The most frequency site (7/10) was at the toe of the anastomosis. Further, the most common cause was uneven spacing or small margin of the stitches or both. Emergencies occurred during the training process included hypotension (7 procedures), tachyarrhythmia (4 procedures), and low blood oxygen saturation (1 procedure). This study demonstrated the safety and feasibility of our new live pig model in training resident surgeons. The simulative arteries can be easily accomplished and were long enough to place at least 6 anastomoses. Both on lumen diameter and motion status, they were proven to be a good substitution of the CA. Copyright © 2016. Published by Elsevier Inc.

  3. Micro-CT image-derived metrics quantify arterial wall distensibility reduction in a rat model of pulmonary hypertension

    NASA Astrophysics Data System (ADS)

    Johnson, Roger H.; Karau, Kelly L.; Molthen, Robert C.; Haworth, Steven T.; Dawson, Christopher A.

    2000-04-01

    We developed methods to quantify arterial structural and mechanical properties in excised rat lungs and applied them to investigate the distensibility decrease accompanying chronic hypoxia-induced pulmonary hypertension. Lungs of control and hypertensive (three weeks 11% O2) animals were excised and a contrast agent introduced before micro-CT imaging with a special purpose scanner. For each lung, four 3D image data sets were obtained, each at a different intra-arterial contrast agent pressure. Vessel segment diameters and lengths were measured at all levels in the arterial tree hierarchy, and these data used to generate features sensitive to distensibility changes. Results indicate that measurements obtained from 3D micro-CT images can be used to quantify vessel biomechanical properties in this rat model of pulmonary hypertension and that distensibility is reduced by exposure to chronic hypoxia. Mechanical properties can be assessed in a localized fashion and quantified in a spatially-resolved way or as a single parameter describing the tree as a whole. Micro-CT is a nondestructive way to rapidly assess structural and mechanical properties of arteries in small animal organs maintained in a physiological state. Quantitative features measured by this method may provide valuable insights into the mechanisms causing the elevated pressures in pulmonary hypertension of differing etiologies and should become increasingly valuable tools in the study of complex phenotypes in small-animal models of important diseases such as hypertension.

  4. The effects of hindlimb unweighting on the capacitance of rat small mesenteric veins

    NASA Technical Reports Server (NTRS)

    Dunbar, S. L.; Berkowitz, D. E.; Brooks-Asplund, E. M.; Shoukas, A. A.

    2000-01-01

    Microgravity is associated with an impaired cardiac output response to orthostatic stress. Mesenteric veins are critical in modulating cardiac filling through venoconstriction. The purpose of this study was to determine the effects of simulated microgravity on the capacitance of rat mesenteric small veins. We constructed pressure-diameter relationships from vessels of 21-day hindlimb-unweighted (HLU) rats and control rats by changing the internal pressure and measuring the external diameter. Pressure-diameter relationships were obtained both before and after stimulation with norepinephrine (NE). The pressure-diameter curves of HLU vessels were shifted to larger diameters than control vessels. NE (10(-4) M) constricted veins from control animals such that the pressure-diameter relationship was significantly shifted downward (i.e., to smaller diameters at equal pressure). NE had no effect on vessels from HLU animals. These results indicate that, after HLU, unstressed vascular volume may be increased and can no longer decrease in response to sympathetic stimulation. This may partially underlie the mechanism leading to the exaggerated fall in cardiac output and stroke volume seen in astronauts during an orthostatic stress after exposure to microgravity.

  5. Advanced intimal hyperplasia without luminal narrowing of leptomeningeal arteries in CADASIL.

    PubMed

    Dong, Hairong; Ding, Haixia; Young, Kelly; Blaivas, Mila; Christensen, Paul J; Wang, Michael M

    2013-05-01

    Leptomeningeal artery abnormalities in Cerebral Autosomal-Dominant Arteriopathy with Subcortical Infarcts and Leukoencephalopathy (CADASIL) have not been extensively characterized. We quantified substructure and diameter of leptomeningeal arteries in CADASIL compared with age-matched controls and the very old; in addition, we characterized intimal thickening in CADASIL using immunohistochemistry. Frontal and temporal cortex of 6 genetically proven CADASIL brains (average age, 66 years), 6 controls without symptoms of cerebrovascular disease, and 6 very old brains (average age, 89 years) were examined for leptomeningeal artery intimal, medial, and adventitial thickness; inner diameter; and sclerotic index and for smooth muscle markers. The intima of CADASIL arteries was thickened 5-fold compared with controls and the very aged (P<0.0001). Medial thickness was lower in CADASIL compared with controls and the very old (P<0.01). The adventitia was not significantly increased in CADASIL compared with age-matched controls. Arterial diameters were not smaller in CADASIL compared with controls. Sclerotic index was significantly increased in CADASIL compared with other groups (P<0.00001). Intimal cells in CADASIL expressed smooth muscle actin, S100A4, and vimentin but not desmin. Principle changes of leptomeningeal arteries in CADASIL include intimal thickening and medial thinning, but not luminal narrowing. Smooth muscle-like cells participate in neointimal thickening of CADASIL arteries.

  6. Devices to protect seedlings from deer browsing

    Treesearch

    David A. Marquis

    1977-01-01

    Studies on the Allegheny Plateau of Pennsylvania have shown that several types of wire or plastic tubes can be erected around tree seedlings to protect them from deer browsing. The two most promising devices are a 4- to 6-inch diameter plastic tube with small mesh and a 12-inch diameter tube constructed of chicken wire. Both types need to be at least 5 feet tall to...

  7. Stiffness Indices and Fractal Dimension relationship in Arterial Pressure and Diameter Time Series in-Vitro

    NASA Astrophysics Data System (ADS)

    Cymberknop, L.; Legnani, W.; Pessana, F.; Bia, D.; Zócalo, Y.; Armentano, R. L.

    2011-12-01

    The advent of vascular diseases, such as hypertension and atherosclerosis, is associated to significant alterations in the physical properties of arterial vessels. Evaluation of arterial biomechanical behaviour is related to the assessment of three representative indices: arterial compliance, arterial distensibility and arterial stiffness index. Elasticity is the most important mechanical property of the arterial wall, whose natures is strictly non-linear. Intervention of elastin and collagen fibres, passive constituent elements of the arterial wall, is related to the applied wall stress level. Concerning this, appropriate tools are required to analyse the temporal dynamics of the signals involved, in order to characterize the whole phenomenon. Fractal geometry can be mentioned as one of those techniques. The aim of this study consisted on arterial pressure and diameter signals processing, by means of nonlinear techniques based on fractal geometry. Time series morphology was related to different arterial stiffness states, generated by means of blood flow variations, during experiences performed in vitro.

  8. Combining cell sheet technology and electrospun scaffolding for engineered tubular, aligned, and contractile blood vessels.

    PubMed

    Rayatpisheh, Shahrzad; Heath, Daniel E; Shakouri, Amir; Rujitanaroj, Pim-On; Chew, Sing Yian; Chan-Park, Mary B

    2014-03-01

    Herein we combine cell sheet technology and electrospun scaffolding to rapidly generate circumferentially aligned tubular constructs of human aortic smooth muscles cells with contractile gene expression for use as tissue engineered blood vessel media. Smooth muscle cells cultured on micropatterned and N-isopropylacrylamide-grafted (pNIPAm) polydimethylsiloxane (PDMS), a small portion of which was covered by aligned electrospun scaffolding, resulted in a single sheet of unidirectionally aligned cells. Upon cooling to room temperature, the scaffold, its adherent cells, and the remaining cell sheet detached and were collected on a mandrel to generating tubular constructs with circumferentially aligned smooth muscle cells which possess contractile gene expression and a single layer of electrospun scaffold as an analogue to a small diameter blood vessel's internal elastic lamina (IEL). This method improves cell sheet handling, results in rapid circumferential alignment of smooth muscle cells which immediately express contractile genes, and introduction of an analogue to small diameter blood vessel IEL. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. The cholinomimetic agent carbachol induces headache in healthy subjects.

    PubMed

    Schytz, H W; Wienecke, T; Oturai, P S; Olesen, J; Ashina, M

    2009-02-01

    The parasympathetic nervous system is likely to be involved in migraine pathogenesis. We hypothesized that the cholinomimetic agonist carbachol would induce headache and vasodilation of cephalic and radial arteries. Carbachol (3 microg/kg) or placebo was randomly infused into 12 healthy subjects in a double-blind crossover study. Headache was scored on a verbal rating scale from 0-10. Velocity in the middle cerebral artery (V(MCA)) and diameter of the superficial temporal artery (STA) and radial artery (RA) were recorded. Nine participants developed headache after carbachol compared with three after placebo. The area under the curve for headache was increased after carbachol compared with placebo both during infusion (0-30 min) (P = 0.042) and in the postinfusion period (30-90 min) (P = 0.027). Carbachol infusion caused a drop in V(MCA) (P = 0.003) and an increase in STA diameter (P = 0.006), but no increase in the RA diameter (P = 0.200). In conclusion, the study demonstrated that carbachol caused headache and dilation of cephalic arteries in healthy subjects.

  10. Proteomic Profiling of Tissue-Engineered Blood Vessel Walls Constructed by Adipose-Derived Stem Cells

    PubMed Central

    Wang, Chen; Guo, Fangfang; Zhou, Heng; Zhang, Yun; Xiao, Zhigang

    2013-01-01

    Adipose-derived stem cells (ASCs) can differentiate into smooth muscle cells and have been engineered into elastic small diameter blood vessel walls in vitro. However, the mechanisms involved in the development of three-dimensional (3D) vascular tissue remain poorly understood. The present study analyzed protein expression profiles of engineered blood vessel walls constructed by human ASCs using methods of two-dimensional gel electrophoresis (2DE) and mass spectrometry (MS). These results were compared to normal arterial walls. A total of 1701±15 and 1265±26 protein spots from normal and engineered blood vessel wall extractions were detected by 2DE, respectively. A total of 20 spots with at least 2.0-fold changes in expression were identified, and 38 differently expressed proteins were identified by 2D electrophoresis and ion trap MS. These proteins were classified into seven functional categories: cellular organization, energy, signaling pathway, enzyme, anchored protein, cell apoptosis/defense, and others. These results demonstrated that 2DE, followed by ion trap MS, could be successfully utilized to characterize the proteome of vascular tissue, including tissue-engineered vessels. The method could also be employed to achieve a better understanding of differentiated smooth muscle protein expression in vitro. These results provide a basis for comparative studies of protein expression in vascular smooth muscles of different origin and could provide a better understanding of the mechanisms of action needed for constructing blood vessels that exhibit properties consistent with normal blood vessels. PMID:22963350

  11. Proteomic profiling of tissue-engineered blood vessel walls constructed by adipose-derived stem cells.

    PubMed

    Wang, Chen; Guo, Fangfang; Zhou, Heng; Zhang, Yun; Xiao, Zhigang; Cui, Lei

    2013-02-01

    Adipose-derived stem cells (ASCs) can differentiate into smooth muscle cells and have been engineered into elastic small diameter blood vessel walls in vitro. However, the mechanisms involved in the development of three-dimensional (3D) vascular tissue remain poorly understood. The present study analyzed protein expression profiles of engineered blood vessel walls constructed by human ASCs using methods of two-dimensional gel electrophoresis (2DE) and mass spectrometry (MS). These results were compared to normal arterial walls. A total of 1701±15 and 1265±26 protein spots from normal and engineered blood vessel wall extractions were detected by 2DE, respectively. A total of 20 spots with at least 2.0-fold changes in expression were identified, and 38 differently expressed proteins were identified by 2D electrophoresis and ion trap MS. These proteins were classified into seven functional categories: cellular organization, energy, signaling pathway, enzyme, anchored protein, cell apoptosis/defense, and others. These results demonstrated that 2DE, followed by ion trap MS, could be successfully utilized to characterize the proteome of vascular tissue, including tissue-engineered vessels. The method could also be employed to achieve a better understanding of differentiated smooth muscle protein expression in vitro. These results provide a basis for comparative studies of protein expression in vascular smooth muscles of different origin and could provide a better understanding of the mechanisms of action needed for constructing blood vessels that exhibit properties consistent with normal blood vessels.

  12. Influence of Gender and Age on Average Dimensions of Arteries Forming the Circle of Willis Study by Magnetic Resonance Angiography on Kosovo's Population.

    PubMed

    Shatri, Jeton; Bexheti, Dorentina; Bexheti, Sadi; Kabashi, Serbeze; Krasniqi, Shaip; Ahmetgjekaj, Ilir; Zhjeqi, Valbona

    2017-10-15

    Circulus arteriosus cerebri is the main source of blood supply to the brain; it connects the left and right hemispheres with anterior and posterior parts. Located at the interpenducular fossa at the base of the brain the circle of Willis is the most important source of collateral circulation in the presence of the disease in the carotid or vertebral artery. The purpose of the research is to study the diameter and length of arteries and provide an important source of reference on Kosovo's population. This is an observative descriptive study performed at the University Clinical Center of Kosovo. A randomised sample of 133 angiographic examinations in adult patients of both sexes who were instructed to exploration is included. The diameters and lengths measured in our study were comparable with other brain-cadaver studies especially those performed by MRA. All dimensions of the arteries are larger in male than female, except the diameter of PCoA that is larger in female (p < 0.05) and length of the ACoA (p < 0.05). Significant differences were found in diameters of arteries between the younger and the older age groups. Knowing the dimensions of the arteries of the circle of Willis has a great importance in interventional radiology as well as during anatomy lessons.

  13. Influence of Gender and Age on Average Dimensions of Arteries Forming the Circle of Willis Study by Magnetic Resonance Angiography on Kosovo’s Population

    PubMed Central

    Shatri, Jeton; Bexheti, Dorentina; Bexheti, Sadi; Kabashi, Serbeze; Krasniqi, Shaip; Ahmetgjekaj, Ilir; Zhjeqi, Valbona

    2017-01-01

    BACKGROUND: Circulus arteriosus cerebri is the main source of blood supply to the brain; it connects the left and right hemispheres with anterior and posterior parts. Located at the interpenducular fossa at the base of the brain the circle of Willis is the most important source of collateral circulation in the presence of the disease in the carotid or vertebral artery. AIM: The purpose of the research is to study the diameter and length of arteries and provide an important source of reference on Kosovo’s population. METHODS: This is an observative descriptive study performed at the University Clinical Center of Kosovo. A randomised sample of 133 angiographic examinations in adult patients of both sexes who were instructed to exploration is included. RESULTS: The diameters and lengths measured in our study were comparable with other brain-cadaver studies especially those performed by MRA. All dimensions of the arteries are larger in male than female, except the diameter of PCoA that is larger in female (p < 0.05) and length of the ACoA (p < 0.05). Significant differences were found in diameters of arteries between the younger and the older age groups. CONCLUSION: Knowing the dimensions of the arteries of the circle of Willis has a great importance in interventional radiology as well as during anatomy lessons. PMID:29104678

  14. Retinal arteriolar remodeling evaluated with adaptive optics camera: Relationship with blood pressure levels.

    PubMed

    Gallo, A; Mattina, A; Rosenbaum, D; Koch, E; Paques, M; Girerd, X

    2016-06-01

    To research a retinal arterioles wall-to-lumen ratio or lumen diameter cut-off that would discriminate hypertensive from normal subjects using adaptive optics camera. One thousand and five hundred subjects were consecutively recruited and Adaptive Optics Camera rtx1™ (Imagine-Eyes, Orsay, France) was used to measure wall thickness, internal diameter, to calculate wall-to-lumen ratio (WLR) and wall cross-sectional area of retinal arterioles. Sitting office blood pressure was measured once, just before retinal measurements and office blood pressure was defined as systolic blood pressure>=140mmHg and diastolic blood pressure>=90mmHg. ROC curves were constructed to determine cut-off values for retinal parameters to diagnose office hypertension. In another population of 276 subjects office BP, retinal arterioles evaluation and home blood pressure monitoring were obtained. The applicability of retinal WLR or diameter cut-off values were compared in patients with controlled, masked, white-coat and sustained hypertension. In 1500 patients, a WLR>0.31 discriminated office hypertensive subjects with a 0.57 sensitivity and 0.71 specificity. Lumen diameter<78.2μm discriminated office hypertension with a 0.73 sensitivity and a 0.52 specificity. In the other 276 patients, WLR was higher in sustained hypertension vs normotensive patients (0.330±0.06 vs 0.292±0.05; P<0.001) and diameter was narrower in masked hypertensive vs normotensive subjects (73.0±11.2 vs 78.5±11.6μm; P<0.005). A WLR higher than 0.31 is in favour of office arterial hypertension; a diameter under<78μm may indicate a masked hypertension. Retinal arterioles analysis through adaptive optics camera may help the diagnosis of arterial hypertension, in particular in case of masked hypertension. Copyright © 2016. Published by Elsevier SAS.

  15. Classification of corkscrew collaterals in thromboangiitis obliterans (Buerger's disease): relationship between corkscrew type and prevalence of ischemic ulcers.

    PubMed

    Fujii, Yuichi; Soga, Junko; Nakamura, Shuji; Hidaka, Takayuki; Hata, Takaki; Idei, Naomi; Fujimura, Noritaka; Nishioka, Kenji; Chayama, Kazuaki; Kihara, Yasuki; Higashi, Yukihito

    2010-08-01

    A corkscrew collateral appearance on angiography is one of the diagnostic criteria for Buerger's disease. The purpose of the present study was to classify the angiographic findings of corkscrew collaterals and to evaluate the relationship between corkscrew collateral type and the severity of Buerger's disease. Corkscrew collaterals were assessed on digital subtraction angiography in lower extremities of 28 patients with Buerger's disease (55 limbs). The corkscrew sign was classified into 4 types by size and pattern as follows: type I, artery diameter >2 mm, large helical sign; type II, diameter >1.5 mm and or=1 mm and

  16. Nitric oxide regulates retinal vascular tone in humans.

    PubMed

    Dorner, Guido T; Garhofer, Gerhard; Kiss, Barbara; Polska, Elzbieta; Polak, Kaija; Riva, Charles E; Schmetterer, Leopold

    2003-08-01

    The purpose of the present study was to investigate the contribution of basal nitric oxide (NO) on retinal vascular tone in humans. In addition, we set out to elucidate the role of NO in flicker-induced retinal vasodilation in humans. Twelve healthy young subjects were studied in a three-way crossover design. Subjects received an intravenous infusion of either placebo or NG-monomethyl-L-arginine (L-NMMA; 3 or 6 mg/kg over 5 min), an inhibitor of NO synthase. Thereafter, diffuse luminance flicker was consecutively performed for 16, 32, and 64 s at a frequency of 8 Hz. The effect of L-NMMA on retinal arterial and venous diameter was assessed under resting conditions and during the hyperemic flicker response. Retinal vessel diameter was measured with a Zeiss retinal vessel analyzer. L-NMMA significantly reduced arterial diameter (3 mg/kg: -2%; 6 mg/kg: -4%, P < 0.001) and venous diameter (3 mg/kg: -5%; 6 mg/kg: -8%, P < 0.001). After placebo infusion, flicker induced a significant increase in retinal vessel diameter (P < 0.001). At a flicker duration of 64 s, arterial diameter increased by 4% and venous diameter increased by 3%. L-NMMA did not abolish these hyperemic responses but blunted venous vasodilation (P = 0.017) and arterial vasodilation (P = 0.02) in response to flicker stimulation. Our data indicate that NO contributes to basal retinal vascular tone in humans. In addition, NO appears to play a role in flicker-induced vasodilation of the human retinal vasculature.

  17. Inadequate increase in the volume of major epicardial coronary arteries compared with that in left ventricular mass. Novel concept for characterization of coronary arteries using 64-slice computed tomography.

    PubMed

    Ehara, Shoichi; Okuyama, Takuhiro; Shirai, Nobuyuki; Sugioka, Kenichi; Oe, Hiroki; Itoh, Toshihide; Matsuoka, Toshiyuki; Ikura, Yoshihiro; Ueda, Makiko; Naruko, Takahiko; Hozumi, Takeshi; Yoshiyama, Minoru

    2009-08-01

    Previous studies have shown a correlation between coronary artery cross-sectional diameter and left ventricular (LV) mass. However, no studies have examined the correlation between actual coronary artery volume (CAV) and LV mass. In the present study, measurements of CAV by 64-multislice computed tomography (MSCT) were validated and the relationship between CAV and LV mass was investigated. First, coronary artery phantoms consisting of syringes filled with solutions of contrast medium moving at simulated heart rates were scanned by 64-MSCT. Display window settings permitting accurate calculation of small volumes were optimized by evaluating volume-rendered images of the segmented contrast medium at different window settings. Next, 61 patients without significant coronary artery stenosis were scanned by 64-MSCT with the same protocol as for the phantoms. Coronary arteries were segmented on a workstation and the same window settings were applied to the volume-rendered images to calculate total CAV. Significant correlations between total CAV and LV mass (r=0.660, P<0.0001) were found, whereas an inverse relation was present between total CAV per 100 g of LV mass and LV mass. The novel concept of "CAV" for the characterization of coronary arteries may prove useful for future research, particularly on the causes of LV hypertrophy.

  18. Comparative Cooling Season Performance of Air Distribution Systems in Multistory Townhomes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    A. Poerschke; Beach, R.; Beggs, T.

    2016-08-26

    IBACOS investigated the performance of a small-diameter high velocity heat pump system compared to a conventional system in a new construction triplex townhouse. A ductless heat pump system also was installed for comparison, but the homebuyer backed out because of aesthetic concerns about that system. In total, two buildings, having identical solar orientation and comprised of six townhomes, were monitored for comfort and energy performance. Results show that the small-diameter system provides more uniform temperatures from floor to floor in the three-story townhome. No clear energy consumption benefit was observed from either system. The builder is continuing to explore themore » small-diameter system as its new standard system to provide better comfort and indoor air quality. The homebuilder also explored the possibility of shifting its townhome product to meet the U.S. Department of Energy Challenge Home National Program Requirements.« less

  19. Building multidevice pipeline constructs of favorable metal coverage: a practical guide.

    PubMed

    Shapiro, M; Raz, E; Becske, T; Nelson, P K

    2014-08-01

    The advent of low-porosity endoluminal devices, also known as flow diverters, exemplified by the Pipeline in the United States, produced the greatest paradigm shift in cerebral aneurysm treatment since the introduction of detachable coils. Despite robust evidence of efficacy and safety, key questions regarding the manner of their use remain unanswered. Recent studies demonstrated that the Pipeline device geometry can dramatically affect its metal coverage, emphasizing the negative effects of oversizing the device relative to its target vessels. This follow-up investigation focuses on the geometry and coverage of multidevice constructs. A number of Pipeline devices were deployed in tubes of known diameters and photographed, and the resultant coverage was determined by image segmentation. Multidevice segmentation images were created to study the effects of telescoped devices and provide an estimate of coverages resulting from device overlap. Double overlap yields a range of metal coverage, rather than a single value, determined by the diameters of both devices, the size of the recipient artery, and the degree to which strands of the overlapped devices are coregistered with each other. The potential variation in coverage is greatest during overlap of identical-diameter devices, for example, ranging from 24% to 41% for two 3.75-mm devices deployed in a 3.5-mm vessel. Overlapping devices of progressively different diameters produce correspondingly more uniform ranges of coverage, though reducing the maximum achievable value, for example, yielding a 33%-34% range for 3.75- and 4.75-mm devices deployed in the same 3.5-mm vessel. Rational strategies for building multidevice constructs can achieve favorable geometric outcomes. © 2014 by American Journal of Neuroradiology.

  20. [Microsurgical anatomy importance of A1-anterior communicating artery complex].

    PubMed

    Monroy-Sosa, Alejandro; Pérez-Cruz, Julio César; Reyes-Soto, Gervith; Delgado-Hernández, Carlos; Macías-Duvignau, Mario Alberto; Delgado-Reyes, Luis

    2013-01-01

    The anterior cerebral artery originates from the bifurcation of the internal carotid artery lateral to the optic chiasm, then joins with its contralateral counterpart via the anterior communicating artery. A1-anterior communicating artery complex is the most frequent anatomical variants and is the major site of aneurysms between 30 to 37%. Know the anatomy microsurgical, variants anatomical and importance of complex precommunicating segment-artery anterior communicating in surgery neurological of the pathology vascular, mainly aneurysms, in Mexican population. The study was performed in 30 brains injected. Microanatomy was studied (length and diameter) of A1-anterior communicating artery complex and its variants. 60 segments A1, the average length of left side was 11.35 mm and 11.84 mm was right. The average diameter of left was 1.67 mm and the right was 1.64 mm. The average number of perforators on the left side was 7.9 and the right side was 7.5. Anterior communicating artery was found in 29 brains of the optic chiasm, its course depended on the length of the A1 segment. The average length of the segment was 2.84 mm, the average diameter was 1.41 mm and the average number of perforators was 3.27. A1-anterior communicating artery complex variants were found in 18 (60%) and the presence of two blister-like aneurysms. It is necessary to understand the A1-anterior communicating artery complex microanatomy of its variants to have a three-dimensional vision during aneurysm surgery.

  1. Endothelial dysfunction assessment by flow-mediated dilation in a high-altitude population.

    PubMed

    Calderón-Gerstein, Walter S; López-Peña, Antonio; Macha-Ramírez, Raúl; Bruno-Huamán, Astrid; Espejo-Ramos, Roxana; Vílchez-Bravo, Stephany; Ramírez-Breña, María; Damián-Mucha, Milagros; Matos-Mucha, Adriana

    2017-01-01

    Endothelial function at high altitude has been measured only in populations that are genetically adapted to chronic hypoxia. The objective of this study was to evaluate endothelial dysfunction (ED) in a nongenetically adapted high-altitude population of the Andes mountains, in Huancayo, Peru (3,250 meters above sea level). Participants included 61 patients: 28 cases and 33 controls. The cases were subjects with hypertension, diabetes mellitus, obesity, or a history of stroke or coronary artery disease. Flow-mediated vasodilation (FMD) of the brachial artery was measured in the supine position, at noon, after 5 minutes of resting. The brachial artery was identified above the elbow. Its basal diameter was measured during diastole, and FMD was tested after 5 minutes of forearm ischemia. Intima-media complex in the right carotid artery was also determined. An increase in the artery's baseline diameter <10% indicated a positive test. Endothelium-independent vasodilation was evaluated with sublingual nitrate administration. The intima-media complex in the right carotid artery was also measured. 100% of diabetics had ED; ED was also found in 68.8% of obese individuals, 55% of hypertensive patients, and 46.5% of controls. Age, height, body mass index, and waist diameter were higher in the cases as compared with the controls. A total of 57.9% (n=11) of the cases and 45.2% (n=19) of the controls presented ED. Patients without ED had a mean increase in brachial artery diameter of 23.16%, while in those with ED it was only 3.84%. Individuals with diabetes or hypertension had a greater thickness of the carotid artery intima media layer (1.092 versus 0.664 cm) ( p =0.037). A positive test for ED was associated with a greater basal diameter of the brachial artery (4.66±0.62 versus 4.23±0.59 cm) ( p =0.02). A total of 7 patients presented paradoxical response, developing posthyperemia vasoconstriction. The proportion of ED was high among controls and among patients with risk factors. Controls showed better FMD profiles than subjects studied in Tibet and the Himalayas.

  2. The effects of the ovarian cycle and pregnancy on uterine vascular impedance and uterine artery mechanics

    PubMed Central

    Sprague, Benjamin J.; Phernetton, Terrance M.; Magness, Ronald R.; Chesler, Naomi C.

    2009-01-01

    Objectives Uterine vascular resistance (UVR) is the ratio of systemic mean arterial pressure to mean uterine blood flow and is sensitive to changes in small arteries and arterioles. However, it provides little or no insight into changes in large, conduit arteries. Fluctuations in estrogen (E2) and progesterone (P4) levels during the ovarian cycle are thought to cause uterine resistance artery vasodilation; the effects on large arteries are unknown. Herein, our objective was to use the uterine vascular impedance, which is sensitive to changes in small and large arteries, to determine the effects of the ovarian cycle and pregnancy on the entire uterine vasculature. Study Design Uterine vascular perfusion pressure and flow rate were recorded simultaneously on anesthetized sheep in the nonpregnant (NP) luteal (NP-L, n=6) and follicular (NP-F, n=7) phases and in late gestation pregnant (CP, n=10) sheep. Impedance and metrics of impedance (input impedance Z0, index of wave reflection RW, characteristic impedance ZC) were calculated. E2 and P4 levels were measured from jugular vein blood samples. Finally, from pressure-diameter tests post-mortem, large uterine artery circumferential elastic modulus (ECirc) was measured. Significant differences were evaluated by two-way ANOVA or Student’s t-test. Results As expected, E2:P4 was higher in the NP-F group compared to the NP-L group (p<0.05). Also as expected, UVR and Z0 decreased in the follicular phase compared to the luteal (p<0.05), but RW, ZC, and ECirc were unaltered. Pregnancy not only substantially decreased UVR (and Z0) (p<0.00001) but also decreased ZC (p<0.001), RW (p<0.0001), ECirc (p<0.01), and pulse wave velocity (p<0.0001). Conclusions The E2:P4 ratio mediates resistance artery vasodilatation in nonpregnant states, but has no effect on conduit artery size or stiffness. In contrast, pregnancy causes dramatic vasodilation and remodeling, including substantial reductions in conduit artery stiffness and increases in conduit artery size, which affect pulsatile uterine hemodynamics. PMID:19297074

  3. Morphometric analysis of diameter and relationship of vertebral artery with respect to transverse foramen in Indian population

    PubMed Central

    Sureka, Binit; Mittal, Mahesh Kumar; Mittal, Aliza; Agarwal, Mukul Sinha Kanhaiya; Bhambri, Narendra Kumar; Thukral, Brij Bhushan

    2015-01-01

    Purpose: To study the location, origin, size and relationship of the vertebral artery and the transverse foramina in the lower cervical spine by computed tomographic angiography (CTA) measurements in the Indian population. Materials and Methods: A retrospective review of multi-detector CT (MDCT) cerebral angiography scans was done between June 2011 and February 2014. A total of 120 patients were evaluated. The diameter of the vertebral artery (AL) and the shortest distance between the vertebral artery and the medial (M), lateral (L), anterior (A), and posterior (P) borders of transverse foramen were studied. In addition, the shortest distance between the vertebral artery and pedicle (h) was also analyzed. Statistical Analysis: The means and their standard deviations (SD) were calculated in both the sexes. The t-tests were performed to look for significant sexual difference. Results: The largest vertebral artery diameter (AL) was at level C7 on the right side (3.5 ± 0.8) and at the level of C5 on the left side (3.7 ± 0.4). Statistically significant difference between males and females were seen at levels C4, C5, and C7. The diameter of the vertebral artery was smaller in females than males. The L value was greater than other parameters (M, A, P) at the same level in all the measurements. The h value was greatest at C6 level and shortest at C5. Conclusion: CTA is necessary before pedicle screw fixation due to variation in measurements at all levels. The highest potential risk of vertebral artery injury during cervical pedicle screw implantation may be at C5, then at C4, and the safest is at C7. PMID:25969640

  4. Staged curative treatment of a complex direct carotid-cavernous fistula with a large arterial defect and an 'oversized' internal carotid artery.

    PubMed

    Bender, Matthew T; Lin, Li-Mei; Coon, Alexander L; Colby, Geoffrey P

    2017-06-14

    This is a case of a high-flow, post-traumatic direct carotid-cavernous fistula with a widened arterial defect and a large-diameter internal carotid artery (ICA). The unique aspect of this case is the oversized ICA, >8mm in diameter, which is both a pathological and a therapeutic challenge, given the lack of available neuroendovascular devices for full vessel reconstruction. We present a planned two-stage embolisation paradigm for definitive treatment. Transarterial coil embolisation is performed as the first stage to disconnect the fistula and normalise flow in the ICA. A 3-month recovery period is then allowed for reduction in carotid diameter. Repair of the large vessel defect and pseudoaneurysm is performed as a second stage in a delayed fashion with a flow-diverting device. Follow-up angiography at 6 months demonstrates obliteration of the fistula and curative ICA reconstruction to a diameter <5mm. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. Early signs that predict later haemodynamically significant patent ductus arteriosus.

    PubMed

    Engür, Defne; Deveci, Murat; Türkmen, Münevver K

    2016-03-01

    Our aim was to determine the optimal cut-off values, sensitivity, specificity, and diagnostic power of 12 echocardiographic parameters on the second day of life to predict subsequent ductal patency. We evaluated preterm infants, born at ⩽32 weeks of gestation, starting on their second day of life, and they were evaluated every other day until ductal closure or until there were clinical signs of re-opening. We measured transductal diameter; pulmonary arterial diastolic flow; retrograde aortic diastolic flow; pulsatility index of the left pulmonary artery and descending aorta; left atrium and ventricle/aortic root ratio; left ventricular output; left ventricular flow velocity time integral; mitral early/late diastolic flow; and superior caval vein diameter and flow as well as performed receiver operating curve analysis. Transductal diameter (>1.5 mm); pulmonary arterial diastolic flow (>25.6 cm/second); presence of retrograde aortic diastolic flow; ductal diameter by body weight (>1.07 mm/kg); left pulmonary arterial pulsatility index (⩽0.71); and left ventricle to aortic root ratio (>2.2) displayed high sensitivity and specificity (p0.9). Parameters with moderate sensitivity and specificity were as follows: left atrial to aortic root ratio; left ventricular output; left ventricular flow velocity time integral; and mitral early/late diastolic flow ratio (p0.05) had low diagnostic value. Left pulmonary arterial pulsatility index, left ventricle/aortic root ratio, and ductal diameter by body weight are useful adjuncts offering a broader outlook for predicting ductal patency.

  6. Uterine distension differentially affects remodelling and distensibility of the uterine vasculature in non-pregnant rats.

    PubMed

    Osol, George; Barron, Carolyn; Mandalà, Maurizio

    2012-01-01

    During pregnancy the mammalian uterine circulation undergoes significant expansive remodelling necessary for normal pregnancy outcome. The underlying mechanisms are poorly defined. The goal of this study was to test the hypothesis that myometrial stretch actively stimulates uterine vascular remodelling by developing a new surgical approach to induce unilateral uterine distension in non-pregnant rats. Three weeks after surgery, which consisted of an infusion of medical-grade silicone into the uterine lumen, main and mesometrial uterine artery and vein length, diameter and distensibility were recorded. Radial artery diameter, distensibility and vascular smooth muscle mitotic rate (Ki67 staining) were also measured. Unilateral uterine distension resulted in significant increases in the length of main uterine artery and vein and mesometrial segments but had no effect on vessel diameter or distensibility. In contrast, there were significant increases in the diameter of the radial arteries associated with the distended uterus. These changes were accompanied by reduced arterial distensibility and increased vascular muscle hyperplasia. In summary, this is the first report to show that myometrial stretch is a sufficient stimulus to induce significant remodelling of uterine vessels in non-pregnant rats. Moreover, the results indicate differential regulation of these growth processes as a function of vessel size and type.

  7. Correction of Non-Linear Propagation Artifact in Contrast-Enhanced Ultrasound Imaging of Carotid Arteries: Methods and in Vitro Evaluation.

    PubMed

    Yildiz, Yesna O; Eckersley, Robert J; Senior, Roxy; Lim, Adrian K P; Cosgrove, David; Tang, Meng-Xing

    2015-07-01

    Non-linear propagation of ultrasound creates artifacts in contrast-enhanced ultrasound images that significantly affect both qualitative and quantitative assessments of tissue perfusion. This article describes the development and evaluation of a new algorithm to correct for this artifact. The correction is a post-processing method that estimates and removes non-linear artifact in the contrast-specific image using the simultaneously acquired B-mode image data. The method is evaluated on carotid artery flow phantoms with large and small vessels containing microbubbles of various concentrations at different acoustic pressures. The algorithm significantly reduces non-linear artifacts while maintaining the contrast signal from bubbles to increase the contrast-to-tissue ratio by up to 11 dB. Contrast signal from a small vessel 600 μm in diameter buried in tissue artifacts before correction was recovered after the correction. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  8. The Effects of Hemodynamic Alterations on Lung Volumes in Fetuses with Tetralogy of Fallot: An MRI Study.

    PubMed

    Berger-Kulemann, Vanessa; Berger, Rudolf; Mlczoch, Elisabeth; Sternal, Daniel; Mailath-Pokorny, Mariella; Hachemian, Nilouparak; Prayer, Daniela; Weber, Michael; Salzer-Muhar, Ulrike

    2015-08-01

    This study assessed whether the presence of tetralogy of Fallot (TOF) affects fetal lung development and whether these fetuses are at risk of pulmonary hypoplasia (PH). Furthermore, we investigated whether the degree of the concomitant pulmonary valve (PV) stenosis or a stenosis in the branch pulmonary arteries correlates with the fetal lung volume. Lung volumetry was performed in 16 fetuses with TOF who underwent MRI between gestational weeks 21 and 35 and in 22 controls. Fetal biometric data and the diameters of the PVs were evaluated by ultrasound. PV and branch pulmonary artery diameters were standardized (z-scores), and fetal lung volume/fetal body weight (FLV/FBW) ratios (ml/g) were calculated. The mean FLV/FBW ratio (0.031 ± 0.009 ml/g) in the TOF group was statistically significantly lower than in the control group (0.041 ± 0.009 ml/g; P = 0.003). None of the fetuses with TOF met the criterion for PH. FLV did not correlate with the degree of PV stenosis, but rather with the presence of a significant stenosis in at least one branch pulmonary artery. The presence of TOF moderately affects fetal lung growth, which is apparently not dependent on the degree of the PV stenosis. However, only an additional stenosis in at least one branch pulmonary artery was associated with a small FLV, but not with PH. Thus, reduced pulmonary blood flow may be offset by additional factors, such as the ability to establish a sufficient collateral system and to alter structural vascular size and, thus, pulmonary vascular resistance.

  9. Infrared laser sealing of porcine vascular tissues using a 1,470 nm diode laser: Preliminary in vivo studies.

    PubMed

    Cilip, Christopher M; Kerr, Duane; Latimer, Cassandra A; Rosenbury, Sarah B; Giglio, Nicholas C; Hutchens, Thomas C; Nau, William H; Fried, Nathaniel M

    2017-04-01

    Infrared (IR) lasers are being explored as an alternative to radiofrequency (RF) and ultrasonic (US) devices for rapid hemostasis with minimal collateral zones of thermal damage and tissue necrosis. Previously, a 1,470 nm IR laser sealed and cut ex vivo porcine renal arteries of 1-8 mm diameter in 2 seconds, yielding burst pressures greater than 1,200 mmHg and thermal coagulation zones less than 3 mm. This preliminary study describes in vivo testing of a handheld laser probe in a porcine model. A handheld prototype with vessel/tissue clasping mechanism was tested on 73 blood vessels less than 6 mm diameter using 1,470 nm laser power of 35 W for 1-5 seconds. Device power settings, irradiation time, tissue type, vessel diameter, and histology sample number were recorded for each procedure. The probe was evaluated for hemostasis after sealing isolated and bundled arteriole/venous (A/V) vasculature of porcine abdomen and hind leg. Sealed vessel samples were collected for histological analysis of lateral thermal damage. Hemostasis was achieved in 57 of 73 seals (78%). The probe consistently sealed vasculature in small bowel mesentery, mesometrium, and gastrosplenic and epiploic regions. Seal performance was less consistent on hind leg vasculature including saphenous arteries/bundles and femoral and iliac arteries. Collagen denaturation averaged 1.6 ± 0.9 mm in eight samples excised for histologic examination. A handheld laser probe sealed porcine vessels, in vivo. Further probe development and laser parameter optimization is necessary before infrared lasers may be evaluated as an alternative to RF and US vessel sealing devices. Lasers Surg. Med. 49:366-371, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  10. Implications of renal artery anatomy for endovascular repair using fenestrated, branched, or parallel stent graft techniques.

    PubMed

    Mendes, Bernardo C; Oderich, Gustavo S; Reis de Souza, Leonardo; Banga, Peter; Macedo, Thanila A; DeMartino, Randall R; Misra, Sanjay; Gloviczki, Peter

    2016-05-01

    This study evaluated renal artery (RA) and accessory renal artery (ARA) anatomy and implications for endovascular repair using fenestrated, branched, or parallel (chimney, snorkel, and periscope) stent graft techniques. We analyzed the digital computed tomography angiograms of 520 consecutive patients treated by open or fenestrated endovascular repair for complex abdominal aortic aneurysms (2000-2012). RA/ARA anatomy was assessed using diameter, length, angles, and kidney perfusion based on analysis of estimated volumetric kidney parenchyma. Endovascular suitability was determined by RA diameter ≥4 mm, length to RA bifurcation ≥13 mm, and preservation of >75% of a single kidney or >60% of two kidneys by volumetric kidney parenchyma analysis. There were 222 juxtarenal (43%), 241 suprarenal (46%), and 57 type IV thoracoabdominal aortic aneurysms (11%), Analysis of 1009 RAs and 177 ARAs showed endovascular incorporation was possible in 884 RAs (88%) and 30 ARAs (17%) using the proposed criteria. One or more factors rendered RA incorporation unsuitable in 97 patients (19%), including early bifurcation in 45 (9%), small diameter in 28 (5%), or inability to preserve kidney parenchyma in 28 (5%). Other anatomic issues were present in 170 patients (33%) that would increase technical difficulty to RA incorporation using transfemoral access, including excessive downward angulation in 125 (24%), high-grade stenosis in 51 (10%), or prior renal stents in 11 (2%). Independent of the endovascular technique that is selected to treat a complex abdominal aortic aneurysm, one of five patients has anatomic limitations to endovascular incorporation. In these patients, open repair may provide the best alterative to maximize RA patency and preserve renal function. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  11. The effects of intrathecal nicergoline and nimodipine in cerebral vasospasm: an experimental study in rabbits.

    PubMed

    Solmaz, Ilker; Onal, Mehmet Bulent; Civelek, Erdinc; Kircelli, Atilla; Ongoru, Onder; Ugurel, Sahin; Erdogan, Ersin; Gonul, Engin

    2011-01-01

    the aim of this study was to assess and to compare the ability of intrathecal nicergoline and nimodipine in prevention of cerebral vasospasm in a rabbit model of subarachnoid hemorrhage (SAH). twenty male New Zealand white rabbits were allocated into four groups randomly. Subarachnoid hemorrhage was induced by injecting autologous blood into the cisterna magna. The treatment groups were as follows: (1) control [no SAH (n = 5)], (2) SAH only (n = 5), (3) SAH plus nimodipine (n = 5), and (4) SAH plus nicergoline (n = 5). there was a statistically significant difference between the mean basilar artery cross-sectional areas and the mean arterial wall thickness measurements of the control and SAH-only groups (p < 0.05). Basilar artery vessel diameter and luminal section areas in group 3 were significantly higher than in group 2 (p < 0.05). Basilar artery vessel diameter and basilar artery luminal section areas in group 4 were significantly higher than in group 2 (p < 0.05). There was no significant difference between basilar artery vessel diameter and basilar artery luminal section areas in group 3 and group 4. these findings demonstrate that intrathecal nicergoline has a vasodilatatory effect in an experimental model of SAH in rabbits but not more than that of nimodipine.

  12. Feasibility of a transient elastography technique for in vitro arterial elasticity assessment.

    PubMed

    Brum, J; Balay, G; Bia, D; Armentano, R L; Negreira, C

    2010-01-01

    The early detection of biomechanical modifications in the arterial wall could be used as a predictor factor for various diseases, for example hypertension or atherosclerosis. In this work a transient elastography technique is used for the in vitro evaluation of the arterial wall elasticity. The obtained Young modulus is compared with the one obtained by a more classical approach: pressure-diameter relationships. As a sample an arterial phantom made of PolyVinyl Alcohol (PVA) gel was used. Diameter variation due to pressure variation inside the phantom was recorded by means of ultrasound. Through both techniques similar Young modulus estimations are obtained showing in this way the feasibility of applying transient elastography for the arterial wall elasticity assessment.

  13. Decellularization of Human Internal Mammary Artery: Biomechanical Properties and Histopathological Evaluation.

    PubMed

    Kajbafzadeh, Abdol-Mohammad; Khorramirouz, Reza; Kameli, Seyede Maryam; Hashemi, Javad; Bagheri, Amin

    2017-01-01

    This study undertook to create small-diameter vascular grafts and assess their structure and mechanical properties to withstand arterial implantation. Twenty samples of intact human internal mammary arteries (IMAs) were collected and decellularized using detergent-based methods. To evaluate residual cellular and extracellular matrix (ECM) components, histological analysis was performed. Moreover, collagen typing and ECM structure were analyzed by Picrosirius red and Movat's pentachrome staining. Scanning electron microscopy was also applied to assess microarchitecture of both endothelial and adventitial surfaces of native and decellularized arterial samples. Furthermore, mechanical tests were performed to evaluate the rigidity and suture strength of the arteries. Human IMAs were completely decellularized in all three segments (proximal, middle, and distal). ECM proteins such as collagen and elastic fibers were efficiently preserved and no structural distortion in intima, media, and adventitial surfaces was observed. The parameters of the mechanical tests revealed no significant differences in the mechanical properties of decellularized arteries in comparison to native arteries with considerable strength, suture retention, and stress relaxation (Young's modulus [MPa] = 0.22 ± 0.023 [native] and 0.22 ± 0.015 [acellular]; and suture strength 0.56 ± 0.19 [native] vs. 0.56 ± 0.12 [acellular], respectively). Decellularized IMA represents a potential arterial scaffold as an alternative to autologous grafts for future arterial bypass surgeries. By this technique, microarchitecture and mechanical integrity of decellularized arteries were considerably similar to native arteries. The goal of this study was to introduce an efficient method for complete decellularization of human IMA and evaluate the ECM and biomechanical properties.

  14. The first perforating branch of the deep femoral artery: A reliable recipient vessel for vascularized fibular grafts: An anatomical study.

    PubMed

    Sur, Yoo Joon; Morsy, Mohamed; Mohan, Anita T; Zhu, Lin; Lachman, Nirusha; Saint-Cyr, Michel

    2016-03-01

    Although the perforating branches of the deep femoral artery have been introduced as recipient vessels for vascularized fibular grafts in the treatment of osteonecrosis of the femoral head, comprehensive knowledge of the related anatomy is deficient. The aims of this study were to provide detailed anatomical data for the perforating branches of the deep femoral artery and validate their usefulness as recipient vessels for vascularized fibular grafts. Anatomical dissection was performed on 11 fresh human cadaveric lower extremities. The number, locations, and diameters of the perforating branches were documented. The topographic relationships with the vastus ridge and the tendinous insertion of the gluteus maximus were clarified. The diameters of the perforating branches were compared with those of the ascending branch of the lateral circumflex femoral and the peroneal arteries. The mean number of perforating branches was 3.5. The mean distances from the vastus ridge to the first, second, and third perforating branches were 8.1, 13.7, and 20.4 cm, respectively. The first perforating branch was always located medial to the tendinous insertion of the gluteus maximus, whereas the second perforating branch was always located distal to the gluteus maximus. The mean diameters of the first, second, third, and fourth perforating branches were 3.1, 2.3, 1.6, and 1.2 mm, respectively. The mean diameters of the ascending branch of the lateral circumflex femoral and the peroneal arteries were 2.0 and 3.6 mm, respectively. The first perforating branch of the deep femoral artery is an appropriate alternative recipient vessel for vascularized fibular grafts in the treatment of osteonecrosis of the femoral head. It has a very consistent anatomy with a suitable location and diameter for anastomosis of the peroneal artery. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  15. Middle cerebral artery diameter changes during rhythmic handgrip exercise in humans.

    PubMed

    Verbree, J; Bronzwaer, Agt; van Buchem, M A; Daemen, Mjap; van Lieshout, J J; van Osch, Mjp

    2017-08-01

    Transcranial Doppler (TCD) sonography is a frequently employed technique for quantifying cerebral blood flow by assuming a constant arterial diameter. Given that exercise increases arterial pressure by sympathetic activation, we hypothesized that exercise might induce a change in the diameter of large cerebral arteries. Middle cerebral artery (MCA) cross-sectional area was assessed in response to handgrip exercise by direct magnetic resonance imaging (MRI) observations. Twenty healthy subjects (11 female) performed three 5 min bouts of rhythmic handgrip exercise at 60% maximum voluntary contraction, alternated with 5 min of rest. High-resolution 7 T MRI scans were acquired perpendicular to the MCA. Two blinded observers manually determined the MCA cross-sectional area. Sufficient image quality was obtained in 101 MCA-scans of 19 subjects (age-range 20-59 years). Mixed effects modelling showed that the MCA cross-sectional area decreased by 2.1 ± 0.8% (p = 0.01) during handgrip, while the heart rate increased by 11 ± 2% (p < 0.001) at constant end-tidal CO 2 (p = 0.10). In conclusion, the present study showed a 2% decrease in MCA cross-sectional area during rhythmic handgrip exercise. This further strengthens the current concept of sympathetic control of large cerebral arteries, showing in vivo vasoconstriction during exercise-induced sympathetic activation. Moreover, care must be taken when interpreting TCD exercise studies as diameter constancy cannot be assumed.

  16. Measured Performance of a Varied Airflow Small-Diameter Duct System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poerschke, Andrew

    2017-03-01

    This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measuremore » of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.« less

  17. Measured Performance of a Varied Airflow Small-Diameter Duct System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poerschke, Andrew

    This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measuremore » of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.« less

  18. Building America Case Study: High-Velocity Small-Diameter Duct System, Pittsburgh, Pennsylvania

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    A. Poerschke

    This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measuremore » of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.« less

  19. The mixability of angiographic contrast with arterial blood

    PubMed Central

    Lieber, Baruch B.; Sadasivan, Chander; Hao, Qing; Seong, Jaehoon; Cesar, Liliana

    2009-01-01

    Purpose: Angiographic contrast that is routinely injected into arteries is used not only to evaluate arterial geometry but also in many cases to assess perfusion. The authors conducted two experiments to examine the dispersion of angiographic contrast injected antegradely into an artery under conditions similar to those found in selective (carotid artery) or superselective (circle of Willis) angiography in order to determine the distance from the catheter tip at which the contrast can be considered fully mixed with the blood. A third experiment investigated whether the contrast once mixed with blood will separate from the mixture under the gravitational field due to a density mismatch. Methods: Experiment I—Under high-speed angiographic acquisition, a bolus of contrast was injected through a catheter along the flow direction of a blood analog fluid flowing through a straight, long, cylindrical tube. The variation in grayscale intensity along the length of the tube was acquired and modeled as the step response to a second-order system. The distance from the catheter tip at which the contrast mixes with the working fluid, the mixing length, was determined as the length along the tube after which the step response settles to within 3% of the steady state value. Experiment II—A bolus of angiographic contrast was injected at rates varying from 0.1 to 1 cc∕s through three different catheter sizes in the left common carotid artery of three rabbits. The average cross-sectional grayscale intensity over one cardiac cycle was calculated at four locations along the artery: Immediately distal to the catheter tip, at location of maximum grayscale intensity, and at 10 and 20 arterial diameters from the catheter tip. The status of mixing within 10 arterial diameters was assessed by differences between the grayscale value at this location and that at the maximum and 20 arterial diameter location. Experiment III—Angiographic contrast was premixed by agitation in three separate vials containing normal saline, canine blood, and glycerol∕distilled-water mixture. The vials were then stationed vertically and angiographic images obtained every 5 min for 1 h. The average intensity of contrast along the vertical length of each vial was obtained for every time point to record any changes in the distribution of contrast over time. Results: The first experiment shows that angiographic contrast completely mixes with steady flowing blood analog fluid within about eight tube diameters of the injection site. The second experiment shows that contrast completely mixes with blood within ten arterial diameters under appropriate injection parameters. The third experiment shows that angiographic contrast does not separate from, or settle out of, contrast-carrying fluid mixtures for a period of 1 h. Conclusions: The results demonstrate that under typical injection conditions in the clinical setting, contrast issuing from the catheter completely mixes with the blood within ten artery diameters downstream of the catheter tip. Once mixed, it does not separate from the blood due to gravity. PMID:19994517

  20. Chronic binge alcohol consumption during pregnancy alters rat maternal uterine artery pressure response.

    PubMed

    Naik, Vishal D; Lunde-Young, Emilie R; Davis-Anderson, Katie L; Orzabal, Marcus; Ivanov, Ivan; Ramadoss, Jayanth

    2016-11-01

    We aimed to investigate pressure-dependent maternal uterine artery responses and vessel remodeling following gestational binge alcohol exposure. Two groups of pregnant rats were used: the alcohol group (28.5% wt/v, 6.0 g/kg, once-daily orogastric gavage in a binge paradigm between gestational day (GD) 5-19) and pair-fed controls (isocalorically matched). On GD20, excised, pressurized primary uterine arteries were studied following equilibration (60 mm Hg) using dual chamber arteriograph. The uterine artery diameter stabilized at 20 mm Hg, showed passive distension at 40 mm Hg, and redeveloped tone at 60 mm Hg. An alcohol effect (P = 0.0025) was observed on the percent constriction of vessel diameter with greater pressure-dependent myogenic constriction. Similar alcohol effect was noted with lumen diameter response (P = 0.0020). The percent change in media:lumen ratio was higher in the alcohol group (P < 0.0001). Thus, gestational alcohol affects pressure-induced uterine artery reactivity, inward-hypotrophic remodeling, and adaptations critical for nutrient delivery to the fetus. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. A New Z Score Curve of the Coronary Arterial Internal Diameter Using the Lambda-Mu-Sigma Method in a Pediatric Population.

    PubMed

    Kobayashi, Tohru; Fuse, Shigeto; Sakamoto, Naoko; Mikami, Masashi; Ogawa, Shunichi; Hamaoka, Kenji; Arakaki, Yoshio; Nakamura, Tsuneyuki; Nagasawa, Hiroyuki; Kato, Taichi; Jibiki, Toshiaki; Iwashima, Satoru; Yamakawa, Masaru; Ohkubo, Takashi; Shimoyama, Shinya; Aso, Kentaro; Sato, Seiichi; Saji, Tsutomu

    2016-08-01

    Several coronary artery Z score models have been developed. However, a Z score model derived by the lambda-mu-sigma (LMS) method has not been established. Echocardiographic measurements of the proximal right coronary artery, left main coronary artery, proximal left anterior descending coronary artery, and proximal left circumflex artery were prospectively collected in 3,851 healthy children ≤18 years of age and divided into developmental and validation data sets. In the developmental data set, smooth curves were fitted for each coronary artery using linear, logarithmic, square-root, and LMS methods for both sexes. The relative goodness of fit of these models was compared using the Bayesian information criterion. The best-fitting model was tested for reproducibility using the validation data set. The goodness of fit of the selected model was visually compared with that of the previously reported regression models using a Q-Q plot. Because the internal diameter of each coronary artery was not similar between sexes, sex-specific Z score models were developed. The LMS model with body surface area as the independent variable showed the best goodness of fit; therefore, the internal diameter of each coronary artery was transformed into a sex-specific Z score on the basis of body surface area using the LMS method. In the validation data set, a Q-Q plot of each model indicated that the distribution of Z scores in the LMS models was closer to the normal distribution compared with previously reported regression models. Finally, the final models for each coronary artery in both sexes were developed using the developmental and validation data sets. A Microsoft Excel-based Z score calculator was also created, which is freely available online (http://raise.umin.jp/zsp/calculator/). Novel LMS models with which to estimate the sex-specific Z score of each internal coronary artery diameter were generated and validated using a large pediatric population. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  2. Pulmonary vascular remodelling in a high-altitude Aymara Indian

    NASA Astrophysics Data System (ADS)

    Heath, Donald; Williams, David

    1991-12-01

    A histological study of the pulmonary vasculature in a young male high-altitude Aymara Indian revealed four aspects of interest. There was muscularization of the terminal portion of the pulmonary arterial tree to involve pulmonary arterioles as small as 15 μm in diameter, thus forming a basis for the slightly increased pulmonary vascular resistance of native highlanders. Intimal longitudinal muscle was found in pulmonary arteries and arterioles and thought to be due to chronic alveolar hypoxia. Inner muscular tubes similar to those found in chronic obstructive lung disease were present. Pulmonary veins and venules also showed intimal muscularization suggesting that alveolar hypoxia affects vascular smooth muscle cells per se irrespective of their situation. The nature of the remodelling in a pulmonary blood vessel depends on a combination of hypoxia and haemodynamics.

  3. The collateral network concept: a reassessment of the anatomy of spinal cord perfusion.

    PubMed

    Etz, Christian D; Kari, Fabian A; Mueller, Christoph S; Silovitz, Daniel; Brenner, Robert M; Lin, Hung-Mo; Griepp, Randall B

    2011-04-01

    Prevention of paraplegia after repair of thoracoabdominal aortic aneurysm requires understanding the anatomy and physiology of the spinal cord blood supply. Recent laboratory studies and clinical observations suggest that a robust collateral network must exist to explain preservation of spinal cord perfusion when segmental vessels are interrupted. An anatomic study was undertaken. Twelve juvenile Yorkshire pigs underwent aortic cannulation and infusion of a low-viscosity acrylic resin at physiologic pressures. After curing of the resin and digestion of all organic tissue, the anatomy of the blood supply to the spinal cord was studied grossly and with light and electron microscopy. All vascular structures at least 8 μm in diameter were preserved. Thoracic and lumbar segmental arteries give rise not only to the anterior spinal artery but to an extensive paraspinous network feeding the erector spinae, iliopsoas, and associated muscles. The anterior spinal artery, mean diameter 134 ± 20 μm, is connected at multiple points to repetitive circular epidural arteries with mean diameters of 150 ± 26 μm. The capacity of the paraspinous muscular network is 25-fold the capacity of the circular epidural arterial network and anterior spinal artery combined. Extensive arterial collateralization is apparent between the intraspinal and paraspinous networks, and within each network. Only 75% of all segmental arteries provide direct anterior spinal artery-supplying branches. The anterior spinal artery is only one component of an extensive paraspinous and intraspinal collateral vascular network. This network provides an anatomic explanation of the physiological resiliency of spinal cord perfusion when segmental arteries are sacrificed during thoracoabdominal aortic aneurysm repair. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  4. Long-term exposure to airborne particles and arterial stiffness: the Multi-Ethnic Study of Atherosclerosis (MESA).

    PubMed

    O'Neill, Marie S; Diez-Roux, Ana V; Auchincloss, Amy H; Shen, Mingwu; Lima, João A; Polak, Joseph F; Barr, R Graham; Kaufman, Joel; Jacobs, David R

    2011-06-01

    Increased arterial stiffness could represent an intermediate subclinical outcome in the mechanistic pathway underlying associations between average long-term pollution exposure and cardiovascular events. We hypothesized that 20 years of exposure to particulate matter (PM) ≤ 2.5 and 10 μm in aerodynamic diameter (PM2.5 and PM10, respectively) would be positively associated with arterial stiffness in 3,996 participants from the Multi-Ethnic Study of Atherosclerosis (MESA) who were seen at six U.S. study sites. We assigned pollution exposure during two decades preceding a clinical exam (2000-2002) using observed PM10 from monitors nearest participants' residences and PM10 and PM2.5 imputed from a space-time model. We examined three log-transformed arterial stiffness outcome measures: Young's modulus (YM) from carotid artery ultrasound and large (C1) and small (C2) artery vessel compliance from the radial artery pulse wave. All associations are expressed per 10 μg/m3 increment in PM and were adjusted for weather, age, sex, race, glucose, triglycerides, diabetes, waist:hip ratio, seated mean arterial pressure, smoking status, pack-years, cigarettes per day, environmental tobacco smoke, and physical activity. C1 and C2 models were further adjusted for heart rate, weight, and height. Long-term average particle exposure was not associated with greater arterial stiffness measured by YM, C1, or C2, and the few associations observed were not robust across metrics and adjustment schemes. Long-term particle mass exposure did not appear to be associated with greater arterial stiffness in this study sample.

  5. [Microsurgical anatomy of the perforating arteries in the superior space of the internal carotid artery through a pterional approach].

    PubMed

    Qi, Song-tao; Huang, Chuan-ping; Lu, Yun-tao; Pan, Jun; Fan, Jun

    2007-05-01

    To study the microanatomy of the perforating arteries in the superior space of the internal carotid artery visualized through a pterional approach. Twelve (24 sides) perfused cadaver heads were dissected via the pterional approach, and the perforating arteries in the superior space of the internal carotid artery were studied under microscope. The diameter, course and distribution in the anterior perforated substance of the perforating arteries were recorded. All the perforating arteries exposed lied on the side of the brain tissue. The carotid bifurcation on 8 sides had perforating arteries, and 11 sides showed medial lenticulostriate artery of the middle cerebral arteries, with short course and overlapped with another perforating arteries upon entry into the anterior perforated substance. On 4 sides, the medial lenticulostriate artery coincided with the perforating arteries in A1. All 24 sides showed middle lenticulostriate artery and lateral lenticulostriate artery of the middle cerebral arteries. Most of the lenticulostriate arteries originated from the anterior segment of the bifurcation of the middle cerebral arteries. The earlier bifurcation occurred in M1 of the middle cerebral arteries, the more perforating arteries originated. On 22 sides, the anterior cerebral arteries had perforating arteries with many branches, and fewer perforating arteries in a main artery were associated with greater diameter of them. The superior space of the internal carotid artery allows a space for operation, and in some cases, part of the medial leticulostriate arteries and A1 perforating arteries can be severed to obtain larger space for the operation.

  6. Renal artery origins: best angiographic projection angles.

    PubMed

    Verschuyl, E J; Kaatee, R; Beek, F J; Patel, N H; Fontaine, A B; Daly, C P; Coldwell, D M; Bush, W H; Mali, W P

    1997-10-01

    To determine the best projection angles for imaging the renal artery origins in profile. A mathematical model of the anatomy at the renal artery origins in the transverse plane was used to analyze the amount of aortic lumen that projects over the renal artery origins at various projection angles. Computed tomographic (CT) angiographic data about the location of 400 renal artery origins in 200 patients were statistically analyzed. In patients with an abdominal aortic diameter no larger than 3.0 cm, approximately 0.5 mm of the proximal part of the renal artery and origin may be hidden from view if there is a projection error of +/-10 degrees from the ideal image. A combination of anteroposterior and 20 degrees and 40 degrees left anterior oblique projections resulted in a 92% yield of images that adequately profiled the renal artery origins. Right anterior oblique projections resulted in the least useful images. An error in projection angle of +/-10 degrees is acceptable for angiographic imaging of the renal artery origins. Patients sex, site of interest (left or right artery), and local diameter of the abdominal aorta are important factors to consider.

  7. Composite materials from forest biomass : a review of current practices, science, and technology

    Treesearch

    Roger M. Rowell

    2007-01-01

    Renewable and sustainable composite materials can be produced using forest biomass if we maintain healthy forests. Small diameter trees and other forest biomass can be processed in the forest into small solid wood pieces, sliced veneers, strands, flakes, chips, particles and fiber that can be used to make construction composite products such as glued-laminated lumber,...

  8. Onyx embolization of an intraosseous pseudoaneurysm of the middle meningeal artery in a patient with meningiomatosis, McCune-Albright syndrome, and gray platelet syndrome.

    PubMed

    Settecase, Fabio; Nicholson, Andrew D; Amans, Matthew R; Higashida, Randall T; Halbach, Van V; Cooke, Daniel L; Dowd, Christopher F; Hetts, Steven W

    2016-03-01

    A 13-year-old boy with meningiomatosis, McCune-Albright syndrome, and gray platelet syndrome presented with an enlarging "lump" on his right forehead. A head CT scan revealed a polyostotic fibrous dysplasia involving the entire skull. A 3.4-cm right frontal osseous cavity and an overlying right forehead subcutaneous soft-tissue mass were seen, measuring 5.2 cm in diameter and 1.6 cm thick. Ultrasound of the cavity and overlying mass showed swirling of blood and an arterialized waveform. MRI revealed an en plaque meningioma underlying the cavity. An intraosseous pseudoaneurysm fed by 3 distal anterior division branches of the right middle meningeal artery (MMA) with contrast extravasation was found on angiography. Two MMA feeders were embolized with Onyx, with anterograde filling of the intraosseous cavity with Onyx. A small pocket of residual intracavity contrast filling postembolization from a smaller third MMA feeder eventually thrombosed and the forehead lump regressed.

  9. Evaluation of the effects of sildenafil citrate (viagra) on vertebral artery blood flow in patients with vertebro-basilar insufficiency.

    PubMed

    Bozgeyik, Zulkif; Berilgen, Sait; Ozdemir, Huseyin; Tekatas, Aslan; Ogur, Erkin

    2008-01-01

    To investigate the effects of sildenafil citrate (Viagra) on the vertebral artery blood flow of patients with vertebro-basilar insufficiency (VBI) using color duplex sonography (CDS). The study included 21 patients with VBI (aged 31-76; mean 61.0 +/- 10.5 yrs). We administered a 50 mg oral dose of sildenafil citrate to all patients. Next, we measured the peak systolic velocity (Vmax), end diastolic velocity (Vmin), resistive index (RI), pulsatility index (PI), diameter, area, and flow volume (FV) of vertebral arteries using CDS before the administration of sildenafil citrate; 45 minutes after, and 75 minutes after administration. Statistical testing was performed using SPSS for windows version 11.0. The statistical test used to determine the outcome of the analysis was the repeated measures analysis of variance (ANOVA) test. Compared to the baseline values, the vertebral artery diameter, area, and FV increased significantly following the administration of sildenafil citrate. The diameter, area and FV increased from 3.39 mm at 45 minutes to 3.64 mm at 75 minutes, 9.43 cm(2) to 10.80 cm(2) at 45 minutes and 10.81 cm(2) at 75 minutes, as well as from 0.07 L/min at baseline to 0.09 L/min at 45 minutes and unchanged at 75 minutes, respectively. Sildenafil citrate elicited a significant effect on vertebral artery diameter, area and FVs.

  10. Vascular provisions for a local utero-ovarian cross-over pathway in new world camelids.

    PubMed

    Del Campo, M R; Del Campo, C H; Ginther, O J

    1996-10-15

    The right uterine horn of alpacas causes luteolysis in the right ovary, whereas the left horn causes luteolysis in both ovaries. Female reproductive tracts were studied in 32 adult llamas, 12 adult alpacas, and 21 mid-gestation female fetuses to determine if there is a dichotomy in the vascular anatomy between the 2 sides. Adult tracts were studied by either injection of colored latex into the veins and arteries followed by tissue clearing or by injection of colored fluids during transillumination. Fetal uteri were studied by transillumination. The angioarchitecture of the ovarian vascular pedicle was similar to that reported for ewes. There was no vessel comparable to the middle uterine artery, which is the largest uterine artery in the other farm species. A striking difference from the uterine vascular of other farm species was the presence of a major branch of the right uterine artery that crossed the cranial intercornual area to supply much of the left uterine horn. A corresponding major vein originated from the left horn, crossed the mid-line, and terminated as a branch of the right uterine vein. Thus, the vascular anatomy indicated that much venous blood from the left horn drained to the right side. This was confirmed by injection of colored fluid into a small venous branch at the tip of the left horn. The prominent cross-over vessels were observed in the fetal uteri, and the diameter of the left uterine fetal horn (6.7 +/- 0.6 mm) was greater (P < 0.001) than the diameter of the right horn (5.8 +/- 0.5 mm). The presence of a large cross-over vein traversing from the left horn to the right side is compatible with the hypothesis that the left horn can exert luteolytic control over the corpus luteum in the right ovary through a veno-arterial pathway. The area of veno-arterial transfer of the luteolysin from a vein containing blood from the left horn into an artery supplying the right ovary was not defined in this study. However, the results provide an anatomical basis for functional testing of the cross-over hypothesis and defining the area of venoarterial transfer in camelids.

  11. An everolimus-eluting stent versus a paclitaxel-eluting stent in small vessel coronary artery disease: a pooled analysis from the SPIRIT II and SPIRIT III trials.

    PubMed

    Bartorelli, Antonio L; Serruys, Patrick W; Miquel-Hébert, Karine; Yu, Shui; Pierson, Wes; Stone, Gregg W

    2010-07-01

    To evaluate the safety and efficacy of the XIENCE V everolimus-eluting stent compared to the TAXUS paclitaxel-eluting stent in small vessels. The XIENCE V everolimus-eluting stent (EES) has been shown to improve angiographic and clinical outcomes after percutaneous myocardial revascularization, but its performance in small coronary arteries has not been investigated. In this pooled analysis, we studied a cohort of 541 patients with small coronary vessels (reference diameter <2.765 mm) by using patient and lesion level data from the SPIRIT II and SPIRIT III studies. TAXUS Express (73% of lesions) and TAXUS Liberté (27% of lesions) paclitaxel-eluting stents (PES) were used as controls in SPIRIT II. In SPIRIT III, Taxus Express(2) PES was the control. Mean angiographic in-stent and in-segment late loss was significantly less in the EES group compared with the PES group, (0.15 +/- 0.37 mm vs. 0.30 +/- 0.44 mm; P = 0.011 for in-stent; 0.10 +/- 0.38 mm vs. 0.21 +/- 0.34 mm; P = 0.034 for in-segment). EES also resulted in a significant reduction in composite major adverse cardiac events at 1 year (19/366 [5.2%] vs. 17/159 [10.7%]; P = 0.037), due to fewer non-Q-wave myocardial infarctions and target lesion revascularizations. At 1 year, the rate of non-Q-wave myocardial infarction was significantly lower in the EES group compared with that of the PES group (6/366 [1.6%] vs. 8/159 [5.0%]; P = 0.037). In patients with small vessel coronary arteries, the XIENCE V EES was superior to the TAXUS PES. (c) 2010 Wiley-Liss, Inc.

  12. Ergonovine-induced changes of coronary artery diameter in patients with nonsignificant coronary artery stenosis : relation with lipid profile.

    PubMed

    Nedeljkovic, Milan A; Ostojic, Miodrag C; Beleslin, Branko D; Nedeljkovic, Ivana; Milic, Natasa; Vukcevic, Vladan; Stojkovic, Sinisa; Saponjski, Jovica; Orlic, Dejan; Djordjevic-Dikic, Ana; Stepanovic, Jelena; Giga, Vojislav; Petrasinovic, Zorica; Arandjelovic, Aleksandra; Beleslin, Biljana; Kanjuh, Vladimir

    2007-06-01

    Serum cholesterol is positively associated with the risk of developing coronary heart disease. The aim of this study was to determine the relation between response of coronary arteries to ergonovine provocation and lipid profile in patients with nonsignificant coronary artery disease. 105 patients (46 male, 59 female, mean age 52 +/- 8 years) with chest pain syndrome and nonsignificant coronary artery stenosis (< 50% diameter stenosis) were analyzed. Ergonovine test was performed at the end of diagnostic catheterization. Coronary spasm was defined as total or near total obstruction of the coronary artery. By quantitative coronary arteriography, changes of minimal luminal diameter (MLD) during ergonovine provocation were evaluated. Total cholesterol, LDL and HDL cholesterol, and triglycerides were measured. There was a significant negative correlation between resting MLD and LDL cholesterol (r = -0.215; p = 0.034), and a significant positive correlation between MLD decrease provoked by ergonovine and total cholesterol (r = 0.275; p = 0.006), as well as LDL cholesterol (r = 0.284; p = 0.004), but not for HDL cholesterol and triglycerides (p = NS [not significant]). In patients with nonsignificant coronary artery stenosis evaluated by ergonovine provocation, there was not only a significant negative correlation between MLD and LDL cholesterol, but also a positive correlation between coronary vasoconstriction induced by ergonovine provocation and both total and LDL cholesterol.

  13. Feed artery role in blood flow control to rat hindlimb skeletal muscles.

    PubMed Central

    Williams, D A; Segal, S S

    1993-01-01

    1. Vasomotor tone and reactivity were investigated in feed arteries of the extensor digitorum longus and soleus muscles. Feed arteries are located external to the muscle and give rise to the microcirculation within each muscle. Resting diameter was smaller in feed arteries of the soleus muscle. 2. Feed arteries of both muscles dilated to similar peak values with sodium nitroprusside. 3. Micropressure measurements demonstrated resistance to blood flow in the feed arteries supplying both muscles. Feed arteries supplying soleus muscle demonstrated greater resistance to blood flow compared to feed arteries of extensor digitorum longus muscle. 4. Greater resting tone and larger pressure drop for feed arteries of soleus muscle suggest greater range of flow control compared to feed arteries of extensor digitorum longus muscle. 5. In both muscles, feed artery diameter increased with muscle contraction (functional dilatation) and in response to transient ischaemia (reactive dilatation). The magnitude of these responses varied between muscles. 6. Feed arteries are active sites of blood flow control in extensor digitorum longus and soleus muscles of the rat. These muscles differ in fibre type and recruitment properties. Differences in feed artery reactivity may contribute to differences in blood flow between these muscles observed at rest and during exercise. Images Fig. 2 Fig. 3 Fig. 4 Fig. 5 PMID:8246199

  14. Pulmonary artery segmentation and quantification in sickle cell associated pulmonary hypertension

    NASA Astrophysics Data System (ADS)

    Linguraru, Marius George; Mukherjee, Nisha; Van Uitert, Robert L.; Summers, Ronald M.; Gladwin, Mark T.; Machado, Roberto F.; Wood, Bradford J.

    2008-03-01

    Pulmonary arterial hypertension is a known complication associated with sickle-cell disease; roughly 75% of sickle cell disease-afflicted patients have pulmonary arterial hypertension at the time of death. This prospective study investigates the potential of image analysis to act as a surrogate for presence and extent of disease, and whether the size change of the pulmonary arteries of sickle cell patients could be linked to sickle-cell associated pulmonary hypertension. Pulmonary CT-Angiography scans from sickle-cell patients were obtained and retrospectively analyzed. Randomly selected pulmonary CT-Angiography studies from patients without sickle-cell anemia were used as negative controls. First, images were smoothed using anisotropic diffusion. Then, a combination of fast marching and geodesic active contours level sets were employed to segment the pulmonary artery. An algorithm based on fast marching methods was used to compute the centerline of the segmented arteries. From the centerline, the diameters at the pulmonary trunk and first branch of the pulmonary arteries were measured automatically. Arterial diameters were normalized to the width of the thoracic cavity, patient weight and body surface. Results show that the pulmonary trunk and first right and left pulmonary arterial branches at the pulmonary trunk junction are significantly larger in diameter with increased blood flow in sickle-cell anemia patients as compared to controls (p values of 0.0278 for trunk and 0.0007 for branches). CT with image processing shows great potential as a surrogate indicator of pulmonary hemodynamics or response to therapy, which could be an important tool for drug discovery and noninvasive clinical surveillance.

  15. Brain Perfusion and Arterial Blood Flow Velocity During Prolonged Body Tilting.

    PubMed

    Montero, David; Rauber, Sven

    2016-08-01

    It remains unknown whether brain perfusion is preserved and mirrored by middle cerebral blood flow velocity (MCA BFV) during prolonged changes in body posture. Herein, we examined the impact of sustained (180 min) 30° head-up (HUT) and head-down (HDT) tilt on brain perfusion, as determined by MCA BFV and blood flow in the extracranial arteries. In 10 healthy male subjects, arterial diameters, BFVs, and blood flows were determined in the left internal carotid (ICA) and vertebral (VA) arteries using duplex Doppler ultrasound in supine rest, and 5, 20, 60, 120, and 180 min following 30° HUT and HDT. MCA BFV was recorded throughout with transcranial Doppler ultrasound. ICA as well as VA diameters and blood flows were unaltered during HUT. Likewise, brain blood flow and MCA BFV were preserved with HUT. In the HDT protocol, ICA and VA diameters were gradually increased, although ICA, VA, and brain blood flows were preserved. MCA BFV was progressively reduced during HDT. In addition, MCA BFV was positively associated with ICA BFV (β = 0.9) and negatively associated with ICA diameter (β = -125.5). MCA BFV was positively associated with brain blood flow during HUT (β = 0.2) but not HDT. Brain perfusion is preserved whereas MCA BFV is progressively decreased and associated with extracranial arterial BFV during sustained 30° HDT. Therefore, MCA BFV may not be a surrogate of brain perfusion in conditions including prolonged HDT. Montero D, Rauber S. Brain perfusion and arterial blood flow velocity during prolonged body tilting. Aerosp Med Hum Perform. 2016; 87(8):682-687.

  16. Evaluating endothelial function of the common carotid artery: an in vivo human model.

    PubMed

    Mazzucco, S; Bifari, F; Trombetta, M; Guidi, G C; Mazzi, M; Anzola, G P; Rizzuto, N; Bonadonna, R

    2009-03-01

    Flow mediated dilation (FMD) of peripheral conduit arteries is a well-established tool to evaluate endothelial function. The aims of this study are to apply the FMD model to cerebral circulation by using acetazolamide (ACZ)-induced intracranial vasodilation as a stimulus to increase common carotid artery (CCA) diameter in response to a local increase of blood flow velocity (BFV). In 15 healthy subjects, CCA end-diastolic diameter and BFV, middle cerebral artery (MCA) BFV and mean arterial blood pressure (MBP) were measured at basal conditions, after an intravenous bolus of 1g ACZ, and after placebo (saline) sublingual administration at the 15th and 20th minute. In a separate session, the same parameters were evaluated after placebo (saline) infusion instead of ACZ and after 10 microg/m(2) bs and 300 microg of glyceryl trinitrate (GTN), administered sublingually, at the 15th and 20th minute, respectively. After ACZ bolus, there was a 35% maximal MCA mean BFV increment (14th minute), together with a 22% increase of mean CCA end-diastolic BFV and a CCA diameter increment of 3.9% at the 3rd minute (p=0.024). There were no MBP significant variations up to the 15th minute (p=0.35). After GTN administration, there was a significant increment in CCA diameter (p<0.00001). ACZ causes a detectable CCA dilation in healthy individuals concomitantly with an increase in BFV. Upon demonstration that this phenomenon is endothelium dependent, this experimental model might become a valuable tool to assess endothelial function in the carotid artery.

  17. In vitro evaluation of valve hemodynamics in the pediatric pulmonary outflow tract

    NASA Astrophysics Data System (ADS)

    Schiavone, Nicole; Elkins, Chris; McElhinney, Doff; Eaton, John; Marsden, Alison

    2016-11-01

    Tetraology of Fallot (ToF) is a congenital heart disease that affects 1 in every 2500 newborns each year and requires surgical repair of the right ventricular outflow tract (RVOT) and subsequent placement of an artificial pulmonary valve. While a wide variety of artificial valves are available, essentially all of them become subject to degradation and dysfunction during the patient's lifetime, which leads to additional interventions. However, there is little understanding about the mechanical function of replacement pulmonary valves and no quantitative placement guidelines to ensure maximum failure-free lifetime. This work aims to experimentally assess the biomechanics of pulmonary valves in realistic RVOT geometries using magnetic resonance velocimetry (MRV), which can measure 3D, three-component phase-averaged velocity fields. The RVOT geometries are constructed using 3D printing, allowing for variation in crucial geometric parameters such as the radius of curvature of the main pulmonary artery (MPA) and the dilation of the artery downstream of the valve. A St. Jude Medical Epic valve is secured inside the RVOT geometry and can be interchanged, allowing for variation of the ratio between valve diameter and MPA diameter. This work will discuss the use of MRV to capture the flow structure in the RVOT and evaluate pulmonary valve performance under different conditions.

  18. Preoperative computer simulation for planning of vascular access surgery in hemodialysis patients.

    PubMed

    Zonnebeld, Niek; Huberts, Wouter; van Loon, Magda M; Delhaas, Tammo; Tordoir, Jan H M

    2017-03-06

    The arteriovenous fistula (AVF) is the preferred vascular access for hemodialysis patients. Unfortunately, 20-40% of all constructed AVFs fail to mature (FTM), and are therefore not usable for hemodialysis. AVF maturation importantly depends on postoperative blood volume flow. Predicting patient-specific immediate postoperative flow could therefore support surgical planning. A computational model predicting blood volume flow is available, but the effect of blood flow predictions on the clinical endpoint of maturation (at least 500 mL/min blood volume flow, diameter of the venous cannulation segment ≥4 mm) remains undetermined. A multicenter randomized clinical trial will be conducted in which 372 patients will be randomized (1:1 allocation ratio) between conventional healthcare and computational model-aided decision making. All patients are extensively examined using duplex ultrasonography (DUS) during preoperative assessment (12 venous and 11 arterial diameter measurements; 3 arterial volume flow measurements). The computational model will predict patient-specific immediate postoperative blood volume flows based on this DUS examination. Using these predictions, the preferred AVF configuration is recommended for the individual patient (radiocephalic, brachiocephalic, or brachiobasilic). The primary endpoint is FTM rate at six weeks in both groups, secondary endpoints include AVF functionality and patency rates at 6 and 12 months postoperatively. ClinicalTrials.gov (NCT02453412), and ToetsingOnline.nl (NL51610.068.14).

  19. In vitro reconstruction of hybrid vascular tissue. Hierarchic and oriented cell layers.

    PubMed

    Kanda, K; Matsuda, T; Oka, T

    1993-01-01

    Hybrid vascular tissue was hierarchically reconstructed in vitro. A hybrid medial layer composed of type I collagen gel, in which SMCs derived from a mongrel dog were embedded, was formed on the inner surface of a compliant porous polyurethane graft (internal diameter = 3 mm). Endothelial cells (ECs) from the same animal were seeded and cultured on the hybrid media to build an intimal layer. Subsequently, hierarchically structured grafts constructed in this manner were subjected to pulsatile flow (flow rate: 8.5 ml/min; frequency: 60 rpm; amplitude: 5% of graft outer diameter) of culture medium (Medium 199 supplemented with 20% fetal calf serum). After stress loading for as long as 10 days, tissues were morphologically investigated with a light microscope and a scanning electron microscope. Inner surfaces of the hybrid tissues were covered with EC monolayers that aligned along the direction of the flow (i.e., longitudinally). However, SMCs beneath the intima aligned in the circumferential direction. These cellular orientations resembled those in native muscular arteries. The pulsatile stress loaded hybrid tissue mimicked native muscular arteries with respect to hierarchic structure and cellular orientation. In vitro mechanical stress loading on a hybrid graft might provide a high degree of integrity in terms of tissue structure that promises high tolerance toward hydrodynamic stress and regulation of vasomotor tone upon implantation.

  20. Transcatheter closure of moderate-to-large patent ductus arteriosus in infants using Amplatzer duct occluder.

    PubMed

    Wang, Jou-Kou; Wu, Mei-Hwan; Lin, Ming-Tai; Chiu, Shuenn-Nan; Chen, Chun-An; Chiu, Hsin-Hui

    2010-02-01

    There are difficulties in transcatheter closure of patent ductus arteriosus (PDA) in infants. The 46 infants (mean age 6.2+/-2.7 months; mean body weight 6.3+/-1.6 kg) who underwent PDA closure using the Amplatzer duct occluder (ADO). The indication for using an ADO was a ductus diameter > or =2.5 or 3 mm. Device diameter selected was 1-3 mm larger than ductal diameter. The mean systolic pulmonary artery pressure was 40.9+/-18.2 mmHg. The mean Qp/Qs ratio was 3.1+/-1.2. The mean ductus diameter was 3.3+/-0.8 mm. ADO was successfully deployed in 45 patients. Failure occurred in 1 case. The mean diameter of device used was 5.4+/-1.1 mm. No severe complications occurred. At the 1-month echocardiographic follow-up, a small residual shunt was present in 4 of 45 patients and had disappeared in all 4 patients at the 3-month follow-up. One patient developed a moderate degree of left ventricular outflow tract obstruction 2.3 years after the procedure. Transcatheter closure of PDA in infants using the ADO is a safe and effective method.

  1. Neonatal Arterial Morphology Is Related to Body Size in Abnormal Human Fetal Growth.

    PubMed

    Olander, Rasmus F W; Sundholm, Johnny K M; Ojala, Tiina H; Andersson, Sture; Sarkola, Taisto

    2016-09-01

    Restriction in fetal growth is associated with cardiovascular disease in adulthood. It is unclear whether abnormal intrauterine growth influences arterial morphology during the fetal or neonatal stage. The objective was to study the regional arterial morphology with respect to gestational age and abnormal fetal body size. We studied body anthropometrics and arterial morphology and physiology in 174 neonates born between 31 and 42 weeks of gestation, including neonates with birth weights appropriate, small, and large for age, with very high resolution vascular ultrasound (35-55 MHz). In simple linear regressions, parameters of body size (body weight, body surface area, and organ circumference) and gestational age were statistically significantly associated with common carotid, brachial, femoral arterial parameters (lumen diameter [LD], wall layer thickness [intima-media thickness and intima-media-adventitia thickness], and carotid artery wall stress [CAWS]). Male sex was statistically significantly associated with LD and CAWS. In multiple linear regression models, body size, gestational age, and sex explained a large proportion of the arterial variance (R( 2) range, 0.37-0.47 for LD; 0.09-0.35 for intima-media thickness; 0.21-0.41 for intima-media-adventitia thickness; and 0.23 for CAWS; all models P<0.001). Arterial wall layer thickness, LDs, and CAWS were independently and strongly predicted by body size, and no effect of maternal disease was observed when added to the models. Gestational age and male sex were also independently but more weakly associated with arterial LDs and CAWS (P<0.01), but not with arterial wall layers. These results indicate that the intrauterine growth of fetal arterial LD and wall layer thickness are primarily attributed to body growth overall. LD and CAWS show weaker association with gestational age and sex. © 2016 American Heart Association, Inc.

  2. New high-precision drift-tube detectors for the ATLAS muon spectrometer

    NASA Astrophysics Data System (ADS)

    Kroha, H.; Fakhrutdinov, R.; Kozhin, A.

    2017-06-01

    Small-diameter muon drift tube (sMDT) detectors have been developed for upgrades of the ATLAS muon spectrometer. With a tube diameter of 15 mm, they provide an about an order of magnitude higher rate capability than the present ATLAS muon tracking detectors, the MDT chambers with 30 mm tube diameter. The drift-tube design and the construction methods have been optimised for mass production and allow for complex shapes required for maximising the acceptance. A record sense wire positioning accuracy of 5 μm has been achieved with the new design. In the serial production, the wire positioning accuracy is routinely better than 10 μm. 14 new sMDT chambers are already operational in ATLAS, further 16 are under construction for installation in the 2019-2020 LHC shutdown. For the upgrade of the barrel muon spectrometer for High-Luminosity LHC, 96 sMDT chambers will be contructed between 2020 and 2024.

  3. Exploration of the rapid effects of personal fine particulate matter exposure on arterial hemodynamics and vascular function during the same day.

    PubMed

    Brook, Robert D; Shin, Hwashin H; Bard, Robert L; Burnett, Richard T; Vette, Alan; Croghan, Carry; Thornburg, Jonathan; Rodes, Charles; Williams, Ron

    2011-05-01

    Levels of fine particulate matter [≤ 2.5 μm in aerodynamic diameter (PM(2.5))] are associated with alterations in arterial hemodynamics and vascular function. However, the characteristics of the same-day exposure-response relationships remain unclear. We aimed to explore the effects of personal PM(2.5) exposures within the preceding 24 hr on blood pressure (BP), heart rate (HR), brachial artery diameter (BAD), endothelial function [flow-mediated dilatation (FMD)], and nitroglycerin-mediated dilatation (NMD). Fifty-one nonsmoking subjects had up to 5 consecutive days of 24-hr personal PM(2.5) monitoring and daily cardiovascular (CV) measurements during summer and/or winter periods. The associations between integrated hour-long total personal PM(2.5) exposure (TPE) levels (continuous nephelometry among compliant subjects with low secondhand tobacco smoke exposures; n = 30) with the CV outcomes were assessed over a 24-hr period by linear mixed models. We observed the strongest associations (and smallest estimation errors) between HR and TPE recorded 1-10 hr before CV measurements. The associations were not pronounced for the other time lags (11-24 hr). The associations between TPE and FMD or BAD did not show as clear a temporal pattern. However, we found some suggestion of a negative association with FMD and a positive association with BAD related to TPE just before measurement (0-2 hr). Brief elevations in ambient TPE levels encountered during routine daily activity were associated with small increases in HR and trends toward conduit arterial vasodilatation and endothelial dysfunction within a few hours of exposure. These responses could reflect acute PM(2.5)-induced autonomic imbalance and may factor in the associated rapid increase in CV risk among susceptible individuals.

  4. Variability of Origin of Splanchnic and Renal Vessels From the Thoracoabdominal Aorta.

    PubMed

    Mazzaccaro, D; Malacrida, G; Nano, G

    2015-01-01

    To analyze the variability of origin of the celiac trunk (CT), the superior mesenteric artery (SMA), the right renal artery (RRA), and the left renal artery (LRA) in terms of mutual distances, angle from the sagittal aortic axis (clock position), and ostial diameters on computed tomography angiographies (CTAs) in three groups of patients. One hundred and fifty CTAs of 50 patients with a non-dilated thoracoabdominal aorta (group A), 50 with thoracoabdominal aneurysm (B), and 50 with infrarenal aneurysm (C) were reviewed. The measurements performed on CTAs, as well as the patients' age, sex, and body surface area, were analyzed. p values <.05 were considered statistically significant. The clock position of the CT and the SMA, the diameters of all vessels, and the distance of the CTeSMA followed a Gaussian distribution. In contrast, the clock position of the renal vessels did not follow a normal distribution, and nor did the distances of the SMA-RRA, SMA-LRA, RRA-LRA or the distances between the renal arteries and the aortic bifurcation. The same values did not differ significantly among the three groups, with the exception of the distances between the renal arteries and the aortic bifurcation, significantly greater in group C. The clock position of the LRA and the distances of the SMA-LRA, SMA-RRA, RRA-LRA and between both renal arteries and the aortic bifurcation showed a significant correlation with the increase of aortic diameter. The anatomic variability of the origin of both the CT and the SMA in terms of clock position and mutual distances followed a Gaussian distribution, regardless of group. The same applies to the ostial diameters of renal and visceral vessels. In contrast, the origin of the renal vessels had a statistically significant heterogeneity that seemed to be correlated with the increase of aortic diameter in the mesenteric and renal aortic region.

  5. Relation of Carotid Artery Diameter With Cardiac Geometry and Mechanics in Heart Failure With Preserved Ejection Fraction

    PubMed Central

    Liao, Zhen‐Yu; Peng, Ming‐Cheng; Yun, Chun‐Ho; Lai, Yau‐Huei; Po, Helen L.; Hou, Charles Jia‐Yin; Kuo, Jen‐Yuan; Hung, Chung‐Lieh; Wu, Yih‐Jer; Bulwer, Bernard E.; Yeh, Hung‐I; Tsai, Cheng‐Ho

    2012-01-01

    Background Central artery dilation and remodeling are associated with higher heart failure and cardiovascular risks. However, data regarding carotid artery diameter from hypertension to heart failure have remained elusive. We sought to investigate this issue by examining the association between carotid artery diameter and surrogates of ventricular dysfunction. Methods and Results Two hundred thirteen consecutive patients including 49 with heart failure and preserved ejection fraction (HFpEF), 116 with hypertension, and an additional 48 healthy participants underwent comprehensive echocardiography and tissue Doppler imaging. Ultrasonography of the common carotid arteries was performed for measurement of intima‐media thickness and diameter (CCAD). Cardiac mechanics, including LV twist, were assessed by novel speckle‐tracking software. A substantial graded enlargement of CCAD was observed across all 3 groups (6.8±0.6, 7.7±0.73, and 8.7±0.95 mm for normal, hypertension, and HFpEF groups, respectively; ANOVA P<0.001) and correlated with serum brain natriuretic peptide level (R2=0.31, P<0.001). Multivariable models showed that CCAD was associated with increased LV mass, LV mass‐to‐volume ratio (β‐coefficient=10.9 and 0.11, both P<0.001), reduced LV longitudinal and radial strain (β‐coeffficient=0.81 and −3.1, both P<0.05), and twist (β‐coefficient=−0.84, P<0.05). CCAD set at 8.07 mm as a cut‐off had a 77.6% sensitivity, 82.3% specificity, and area under the receiver operating characteristic curves (AUROC) of 0.86 (95% CI 0.80 to 0.92) in discriminating HFpEF. In addition, CCAD superimposed on myocardial deformation significantly expanded AUROC (for longitudinal strain, from 0.84 to 0.90, P of ΔAUROC=0.02) in heart failure discrimination models. Conclusions Increased carotid artery diameter is associated with worse LV geometry, higher brain natriuretic peptide level, and reduced contractile mechanics in individuals with HFpEF. PMID:23316319

  6. Design, construction, and validation of a rotary multifunctional intravascular diagnostic catheter combining multispectral fluorescence lifetime imaging and intravascular ultrasound.

    PubMed

    Bec, Julien; Xie, Hongtao; Yankelevich, Diego R; Zhou, Feifei; Sun, Yang; Ghata, Narugopal; Aldredge, Ralph; Marcu, Laura

    2012-10-01

    We report the development and validation of an intravascular rotary catheter for bimodal interrogation of arterial pathologies. This is based on a point-spectroscopy scanning time-resolved fluorescence spectroscopy technique enabling reconstruction of fluorescence lifetime images (FLIm) and providing information on arterial intima composition and intravascular ultrasound (IVUS) providing information on arterial wall morphology. The catheter design allows for independent rotation of the ultrasonic and optical channels within an 8 Fr outer diameter catheter sheath and integrates a low volume flushing channel for blood removal in the optical pathways. In the current configuration, the two channels consist of (a) a standard 3 Fr IVUS catheter with single element transducer (40 MHz) and (b) a side-viewing fiber optic (400 μm core). Experiments conducted in tissue phantoms showed the ability of the catheter to operate in an intraluminal setting and to generate coregistered FLIm and IVUS in one pull-back scan. Current results demonstrate the feasibility of the catheter for simultaneous bimodal interrogation of arterial lumen and for generation of robust fluorescence lifetime data under IVUS guidance. These results facilitate further development of a FLIm-IVUS technique for intravascular diagnosis of atherosclerotic cardiovascular diseases including vulnerable plaques.

  7. Arterial Structure and Function in Women and Men Following Long Duration Bed Rest

    NASA Technical Reports Server (NTRS)

    Lee, Stuart M. C.; Stenger, Michael B.; Martin, David S.; Platts, Steven H.

    2008-01-01

    Orthostatic intolerance is a well-recognized consequence of space flight and bed rest (BR), with a greater incidence reported in women. We hypothesized that leg, but not arm, arterial structure and function would be altered following prolonged BR, as a model of space flight, and that women would be more susceptible to BR-induced deconditioning than men. METHODS: Ten volunteers (5 males, 5 females) completed 90 d of 6 head-down BR. Subjects participated in tests of brachial (BA) and anterior tibial (AT) artery endothelium-dependent (flow mediated dilation [FMD] following 5-7 min of arterial occlusion) and endothelium-independent (0.4 mg sublingual nitroglycerin [SN]) vasodilation before BR (PRE) and on days 7 (BR7), 21 (BR21), and 90 (BR90) of BR. Vessel diameter and intimal medial thickness (IMT) were measured by ultrasound. IMT, baseline diameter, and percent change in diameter from baseline during FMD and SN tests were compared across BR and between genders using repeated measures two-way ANOVA with Bonferroni post-hoc tests in which PRE and women were control conditions. RESULTS: Baseline vessel diameter was lower in women than in men in both the BA (p=0.005) and AT (p=0.01) across all days. Baseline AT diameter decreased during BR (p=0.01) and tended to be more profound in women (interaction, p=0.06). AT diameter was reduced in women at BR21 and BR90 (p<0.01) but not in men. In contrast, there was no BR effect on baseline BA diameter. IMT also decreased in the AT (p<0.001) but not in the BA during BR; AT IMT was reduced by BR21 (p<0.05). As a group, there was no effect of BR on AT FMD, BA FMD, and AT SN-dilation, although BA SN-dilation was significantly reduced on BR21 (p=0.01). Across all BR days, women exhibited higher AT FMD (p=0.03), BA FMD (p=0.02), and BA SN-dilation (p=0.01) and tended to demonstrate greater AT SN-dilation (p=0.11). CONCLUSIONS: These preliminary results suggest that arterial remodeling occurs during BR in the leg (decreased diameter and IMT), but not in the arm, and that women appear to be more responsive to BR than men. These changes in the leg, coupled with larger responses to direct and indirect stimulation of the arterial smooth muscle, may be related to the greater incidence of orthostatic intolerance in women after BR and space flight.

  8. Alteration of intraaneurysmal hemodynamics by placement of a self-expandable stent. Laboratory investigation.

    PubMed

    Tateshima, Satoshi; Tanishita, Kazuo; Hakata, Yasuhiro; Tanoue, Shin-ya; Viñuela, Fernando

    2009-07-01

    Development of a flexible self-expanding stent system and stent-assisted coiling technique facilitates endovascular treatment of wide-necked brain aneurysms. The hemodynamic effect of self-expandable stent placement across the neck of a brain aneurysm has not been well documented in patient-specific aneurysm models. Three patient-specific silicone aneurysm models based on clinical images were used in this study. Model 1 was constructed from a wide-necked internal carotid artery-ophthalmic artery aneurysm, and Models 2 and 3 were constructed from small wide-necked middle cerebral artery aneurysms. Neuroform stents were placed in the in vitro aneurysm models, and flow structures were compared before and after the stent placements. Flow velocity fields were acquired with particle imaging velocimetry. In Model 1, a clockwise, single-vortex flow pattern was observed in the aneurysm dome before stenting was performed. There were multiple vortices, and a very small fast flow stream was newly formed in the aneurysm dome after stenting. The mean intraaneurysmal flow velocity was reduced by approximately 23-40%. In Model 2, there was a clockwise vortex flow in the aneurysm dome and another small counterclockwise vortex in the tip of the aneurysm dome before stenting. The small vortex area disappeared after stenting, and the mean flow velocity in the aneurysm dome was reduced by 43-64%. In Model 3, a large, counterclockwise, single vortex was seen in the aneurysm dome before stenting. Multiple small vortices appeared in the aneurysm dome after stenting, and the mean flow velocity became slower by 22-51%. The flexible self-expandable stents significantly altered flow velocity and also flow structure in these aneurysms. Overall flow alterations by the stent appeared favorable for the long-term durability of aneurysm embolization. The possibility that the placement of a low-profile self-expandable stent might induce unfavorable flow patterns such as a fast flow stream in the aneurysm dome cannot be excluded.

  9. Drag reduction by polyethylene glycol in the tail arterial bed of normotensive and hypertensive rats.

    PubMed

    Bessa, K L; Belletati, J F; Santos, L; Rossoni, L V; Ortiz, J P

    2011-08-01

    This study was designed to evaluate the effect of drag reducer polymers (DRP) on arteries from normotensive (Wistar) and spontaneously hypertensive rats (SHR). Polyethylene glycol (PEG 4000 at 5000 ppm) was perfused in the tail arterial bed with (E+) and without endothelium (E-) from male, adult Wistar (N = 14) and SHR (N = 13) animals under basal conditions (constant flow at 2.5 mL/min). In these preparations, flow-pressure curves (1.5 to 10 mL/min) were constructed before and 1 h after PEG 4000 perfusion. Afterwards, the tail arterial bed was fixed and the internal diameters of the arteries were then measured by microscopy and drag reduction was assessed based on the values of wall shear stress (WSS) by computational simulation. In Wistar and SHR groups, perfusion of PEG 4000 significantly reduced pulsatile pressure (Wistar/E+: 17.5 ± 2.8; SHR/E+: 16.3 ± 2.7%), WSS (Wistar/E+: 36; SHR/E+: 40%) and the flow-pressure response. The E- reduced the effects of PEG 4000 on arteries from both groups, suggesting that endothelial damage decreased the effect of PEG 4000 as a DRP. Moreover, the effects of PEG 4000 were more pronounced in the tail arterial bed from SHR compared to Wistar rats. In conclusion, these data demonstrated for the first time that PEG 4000 was more effective in reducing the pressure-flow response as well as WSS in the tail arterial bed of hypertensive than of normotensive rats and these effects were amplified by, but not dependent on, endothelial integrity. Thus, these results show an additional mechanism of action of this polymer besides its mechanical effect through the release and/or bioavailability of endothelial factors.

  10. Laser-driven short-duration heating angioplasty: dilatation performance in cadaver atherosclerotic femoral arteries

    NASA Astrophysics Data System (ADS)

    Shimazaki, Natsumi; Naruse, Sho; Arai, Tsunenori; Imanishi, Nobuaki; Aiso, Sadakazu

    2013-03-01

    The purpose of this study was to investigate the artery dilatation performance of the short-duration heating balloon catheter in cadaver stenotic arteries. We designed a prototype short-duration heating balloon catheter that can heat artery media to around 60 °C in 15-25 s by a combination of laser-driven heat generation and continuous fluid irrigation in the balloon. We performed ex vivo short-duration heating dilatation in the cadaver atherosclerotic femoral arteries (initial percent diameter stenosis was 36-98%), with the maximum balloon temperature of 65+/-5 °C, laser irradiation duration of 25 s, and balloon dilatation pressure of 3.5 atm. The artery lumen configurations before and after the dilatations were assessed with a commercial IVUS system. After the short-duration heating dilatations, the percent diameter stenosis was reduced below 30% without any artery tears or dissections. We estimated that the artery media temperature was raised to around 60 °C in which plaque thickness was below 0.8 mm by a thermal conduction calculation. The estimated maximum temperature in artery adventitia and surrounding tissue was up to 45 °C. We found that the short-duration heating balloon could sufficiently dilate the cadaver stenotic arteries, without thermal injury in artery adventitia and surroundings.

  11. Transcatheter closure of large patent ductus arteriosus with severe pulmonary arterial hypertension in adults: immediate and two-year follow-up results.

    PubMed

    Zhang, Cao-Jin; Huang, Yi-Gao; Huang, Xin-Sheng; Huang, Tao; Huang, Wen-Hui; Xia, Chun-Li; Mo, Yu-Jing

    2012-11-01

    Transcatheter closure of patent ductus arteriosus (PDA) is a well established procedure and an accepted treatment modality for small to moderate-sized PDA. This study aimed to evaluate the immediate and follow-up results of transcatheter closure of large PDAs with severe pulmonary arterial hypertension (PAH) in adults. After a complete hemodynamic evaluation differentiating from the reversibility of severe PAH, transcatheter closure of PDA was performed. Patients were followed up clinically and echocardiographically at 24 hours, 1 month, 3 months, 6 months, 12 months and 24 months after occlusion. Twenty-nine patients had successful occlusion, pulmonary artery pressure (PAP), left ventricular ejection fraction (LVEF) and fractional shortening (FS) significantly decreased immediately after occlusion ((106 ± 25) mmHg vs. (50 ± 14) mmHg, P < 0.01; (63.7 ± 7.2)% vs. (51.4 ± 10.1)%, P < 0.01 and (36.9 ± 8.2)% vs. (28.9 ± 8.6)%, P < 0.05, respectively). At 1 month after PDA closure, the signs and symptoms improved markedly in all 29 patients, and PDAs were completely closed and remained closed during the follow-up. Eighteen patients having different degrees of dyspnea were treated with angiotensin converting enzyme inhibitor (ACEI) and/or digoxin after occlusion. Nine patients whose pulmonary vascular resistence (PVR) > 6 Wood units accepted targeted PAH therapy. After 1 to 3 months of peroral drug therapy, their exercise tolerance improved from New York Heart Association (NYHA) class III-IV to NYHA class I. During follow-up, no latent arrhythmias were found, the left atrial diameter (LAD), left ventricular end-diastolic diameter (LVEDD), left ventricular end-systolic diameter (LVESD), left ventricular mass index (LVMI) and pulmonary artery systolic pressure (PASP) decreased significantly (P < 0.05), and FS and LVEF recovered compared to the immediate postclosure state. However, FS and LVEF remained low compared to the preclosure state. Transcatheter closure of large PDA with severe PAH is feasible, effective, and safe in adults. Significant left ventricular systolic changes may occur after closure of large PDA, and left ventricular function usually recovers within a few months.

  12. Blackcurrant Alters Physiological Responses and Femoral Artery Diameter during Sustained Isometric Contraction

    PubMed Central

    Cook, Matthew David; Myers, Stephen David; Gault, Mandy Lucinda; Willems, Mark Elisabeth Theodorus

    2017-01-01

    Blackcurrant is rich in anthocyanins that may affect exercise-induced physiological responses. We examined tissue oxygen saturation, muscle activity, cardiovascular responses and femoral artery diameter during a submaximal sustained isometric contraction. In a randomised, double-blind, crossover design, healthy men (n = 13, age: 25 ± 4 years, BMI: 25 ± 3 kg·m−2, mean ± SD) ingested New Zealand blackcurrant (NZBC) extract (600 mg∙day−1 CurraNZ™) or placebo (PL) for 7-days separated by 14-days washout. Participants produced isometric maximal voluntary contractions (iMVC) and a 120-s 30%iMVC of the quadriceps with electromyography (EMG), near-infrared spectroscopy, hemodynamic and ultrasound recordings. There was no effect of NZBC extract on iMVC (NZBC: 654 ± 73, PL: 650 ± 78 N). During the 30%iMVC with NZBC extract, total peripheral resistance, systolic, diastolic, and mean arterial pressure were lower with increased cardiac output and stroke volume. With NZBC extract, EMG root mean square of the vastus medialis and muscle oxygen saturation were lower with higher total haemoglobin. During the 30%iMVC, femoral artery diameter was increased with NZBC extract at 30 (6.9%), 60 (8.2%), 90 (7.7%) and 120 s (6.0%). Intake of NZBC extract for 7-days altered cardiovascular responses, muscle oxygen saturation, muscle activity and femoral artery diameter during a 120-s 30%iMVC of the quadriceps. The present study provides insight into the potential mechanisms for enhanced exercise performance with intake of blackcurrant. PMID:28555052

  13. Evaluation of the Effects of Sildenafil Citrate (Viagra) on Vertebral Artery Blood Flow in Patients with Vertebro-Basilar Insufficiency

    PubMed Central

    Berilgen, Sait; Ozdemir, Huseyin; Tekatas, Aslan; Ogur, Erkin

    2008-01-01

    Objective To investigate the effects of sildenafil citrate (Viagra) on the vertebral artery blood flow of patients with vertebro-basilar insufficiency (VBI) using color duplex sonography (CDS). Materials and Methods The study included 21 patients with VBI (aged 31-76; mean 61.0 ± 10.5 yrs). We administered a 50 mg oral dose of sildenafil citrate to all patients. Next, we measured the peak systolic velocity (Vmax), end diastolic velocity (Vmin), resistive index (RI), pulsatility index (PI), diameter, area, and flow volume (FV) of vertebral arteries using CDS before the administration of sildenafil citrate; 45 minutes after, and 75 minutes after administration. Statistical testing was performed using SPSS for windows version 11.0. The statistical test used to determine the outcome of the analysis was the repeated measures analysis of variance (ANOVA) test. Results Compared to the baseline values, the vertebral artery diameter, area, and FV increased significantly following the administration of sildenafil citrate. The diameter, area and FV increased from 3.39 mm at 45 minutes to 3.64 mm at 75 minutes, 9.43 cm2 to 10.80 cm2 at 45 minutes and 10.81 cm2 at 75 minutes, as well as from 0.07 L/min at baseline to 0.09 L/min at 45 minutes and unchanged at 75 minutes, respectively. Conclusion Sildenafil citrate elicited a significant effect on vertebral artery diameter, area and FVs. PMID:19039262

  14. A method for evaluating the murine pulmonary vasculature using micro-computed tomography.

    PubMed

    Phillips, Michael R; Moore, Scott M; Shah, Mansi; Lee, Clara; Lee, Yueh Z; Faber, James E; McLean, Sean E

    2017-01-01

    Significant mortality and morbidity are associated with alterations in the pulmonary vasculature. While techniques have been described for quantitative morphometry of whole-lung arterial trees in larger animals, no methods have been described in mice. We report a method for the quantitative assessment of murine pulmonary arterial vasculature using high-resolution computed tomography scanning. Mice were harvested at 2 weeks, 4 weeks, and 3 months of age. The pulmonary artery vascular tree was pressure perfused to maximal dilation with a radio-opaque casting material with viscosity and pressure set to prevent capillary transit and venous filling. The lungs were fixed and scanned on a specimen computed tomography scanner at 8-μm resolution, and the vessels were segmented. Vessels were grouped into categories based on lumen diameter and branch generation. Robust high-resolution segmentation was achieved, permitting detailed quantitation of pulmonary vascular morphometrics. As expected, postnatal lung development was associated with progressive increase in small-vessel number and arterial branching complexity. These methods for quantitative analysis of the pulmonary vasculature in postnatal and adult mice provide a useful tool for the evaluation of mouse models of disease that affect the pulmonary vasculature. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Decreased Vertebral Artery Hemodynamics in Patients with Loss of Cervical Lordosis

    PubMed Central

    Bulut, Mehmet Deniz; Alpayci, Mahmut; Şenköy, Emre; Bora, Aydin; Yazmalar, Levent; Yavuz, Alpaslan; Gülşen, İsmail

    2016-01-01

    Background Because loss of cervical lordosis leads to disrupted biomechanics, the natural lordotic curvature is considered to be an ideal posture for the cervical spine. The vertebral arteries proceed in the transverse foramen of each cervical vertebra. Considering that the vertebral arteries travel in close anatomical relationship to the cervical spine, we speculated that the loss of cervical lordosis may affect vertebral artery hemodynamics. The aim of this study was to compare the vertebral artery values between subjects with and without loss of cervical lordosis. Material/Methods Thirty patients with loss of cervical lordosis and 30 controls matched for age, sex, and body mass index were included in the study. Sixty vertebral arteries in patients with loss of cervical lordosis and 60 in controls without loss of cervical lordosis were evaluated by Doppler ultrasonography. Vertebral artery hemodynamics, including lumen diameter, flow volume, peak systolic velocity, end-diastolic velocity, and resistive index, were measured, and determined values were statistically compared between the patient and the control groups. Results The means of diameter (p=0.003), flow volume (p=0.002), and peak systolic velocity (p=0.014) in patients were significantly lower as compared to controls. However, there was no significant difference between the 2 groups in terms of the end-diastolic velocity (p=0.276) and resistive index (p=0.536) parameters. Conclusions The present study revealed a significant association between loss of cervical lordosis and decreased vertebral artery hemodynamics, including diameter, flow volume, and peak systolic velocity. Further studies are required to confirm these findings and to investigate their possible clinical implications. PMID:26876295

  16. Decreased Vertebral Artery Hemodynamics in Patients with Loss of Cervical Lordosis.

    PubMed

    Bulut, Mehmet Deniz; Alpayci, Mahmut; Şenköy, Emre; Bora, Aydin; Yazmalar, Levent; Yavuz, Alpaslan; Gülşen, İsmail

    2016-02-15

    BACKGROUND Because loss of cervical lordosis leads to disrupted biomechanics, the natural lordotic curvature is considered to be an ideal posture for the cervical spine. The vertebral arteries proceed in the transverse foramen of each cervical vertebra. Considering that the vertebral arteries travel in close anatomical relationship to the cervical spine, we speculated that the loss of cervical lordosis may affect vertebral artery hemodynamics. The aim of this study was to compare the vertebral artery values between subjects with and without loss of cervical lordosis. MATERIAL AND METHODS Thirty patients with loss of cervical lordosis and 30 controls matched for age, sex, and body mass index were included in the study. Sixty vertebral arteries in patients with loss of cervical lordosis and 60 in controls without loss of cervical lordosis were evaluated by Doppler ultrasonography. Vertebral artery hemodynamics, including lumen diameter, flow volume, peak systolic velocity, end-diastolic velocity, and resistive index, were measured, and determined values were statistically compared between the patient and the control groups. RESULTS The means of diameter (p=0.003), flow volume (p=0.002), and peak systolic velocity (p=0.014) in patients were significantly lower as compared to controls. However, there was no significant difference between the 2 groups in terms of the end-diastolic velocity (p=0.276) and resistive index (p=0.536) parameters. CONCLUSIONS The present study revealed a significant association between loss of cervical lordosis and decreased vertebral artery hemodynamics, including diameter, flow volume, and peak systolic velocity. Further studies are required to confirm these findings and to investigate their possible clinical implications.

  17. Impact of the severity of end-stage liver disease in cardiac structure and function.

    PubMed

    Silvestre, Odilson Marcos; Bacal, Fernando; de Souza Ramos, Danusa; Andrade, Jose L; Furtado, Meive; Pugliese, Vincenzo; Belleti, Elisangela; Andraus, Wellington; Carrilho, Flair José; Carneiro D'Albuquerque, Luiz Augusto; Queiroz Farias, Alberto

    2013-01-01

    The impact of end-stage liver disease (ESLD) in cardiac remodeling of patients with cirrhosis is unknown. Our aim was to correlate the severity of ESLD with morphologic and functional heart changes. 184 patients underwent a protocol providing data on the severity of ESLD and undergoing echocardiography to assess the diameters of the left atrium and right ventricle; the systolic and diastolic diameters of the left ventricle, interventricular septum, and posterior wall of the left ventricle; systolic pulmonary artery pressure; ejection fraction; and diastolic function. Severity of ESLD was assessed by the Model for End-Stage Liver Disease (MELD) score. Left-atrial diameter (r = 0.323; IC 95% 0.190-0.455; p < 0.001), left-ventricular diastolic diameter (r = 0.177; IC 95% 0.033-0.320; p = 0.01) and systolic pulmonary artery pressure (r = 0.185; IC 95% 0.036-0.335; p = 0.02) significantly correlated with MELD score. Patients with MELD ≥ 16 had significantly higher left-atrial diameter and systolic pulmonary artery pressure, compared with patients with MELD scores < 16 points. Changes in cardiac structure and function correlate with the severity of ESLD.

  18. Design and Construction of a Small Vacuum Furnace

    NASA Astrophysics Data System (ADS)

    Peawbang, P.; Thedsakhulwong, A.

    2017-09-01

    The purpose of this research is designed and constructed of a small vacuum furnace. A cylindrical graphite was chosen as the material of the furnace, the cylinder aluminium and copper sheets were employed to prevent the heat radiation that transfers from the furnace to the chamber wall. A rotary pump used, the pressure of graphite furnace can be pumped up to 30 mTorr and heated up to 700 °C driving by wire and the temperature of the chamber wall is relatively remained too low. In addition, heat loss obtained from the graphite furnace by conduction, convection, and radiation were analyzed. The dominating heat loss was found to be caused by the blackbody radiation, which can thus be used to estimate the relationship between graphite furnace temperature and the drive power needed. The cylindrical graphite furnace has an inner diameter of 44 mm, the outer diameter of 60 mm and 45 mm in height, the 355.5 W of power is needed to drive the furnace to 700 °C.

  19. Tactile mapping system: a novel imaging technology for surface topography and elasticity of tissues or organs.

    PubMed

    Oie, Tomonori; Suzuki, Hisato; Fukuda, Toru; Murayama, Yoshinobu; Omata, Sadao; Kanda, Keiichi; Nakayama, Yasuhide

    2009-11-01

    : We demonstrated that the tactile mapping system (TMS) has a high degree of spatial precision in the distribution mapping of surface elasticity of tissues or organs. : Samples used were a circumferential section of a small-caliber porcine artery (diameter: ∼3 mm) and an elasticity test pattern with a line and space configuration for the distribution mapping of elasticity, prepared by regional micropatterning of a 14-μm thick gelatin hydrogel coating on a polyurethane sheet. Surface topography and elasticity in normal saline were simultaneously investigated by TMS using a probe with a diameter of 5 or 12 μm, a spatial interval of 1 to 5 μm, and an indentation depth of 4 μm. : In the test pattern, a spatial resolution in TMS of <5 μm was acquired under water with a minimal probe diameter and spatial interval of the probe movement. TMS was used for the distribution mapping of surface elasticity in a flat, circumferential section (thickness: ∼0.5 mm) of a porcine artery, and the concentric layers of the vascular wall, including the collagen-rich and elastin-rich layers, could be clearly differentiated in terms of surface elasticity at the spatial resolution of <2 μm. : TMS is a simple and inexpensive technique for the distribution mapping of the surface elasticity in vascular tissues at the spatial resolution <2 μm. TMS has the ability to analyze a complex structure of the tissue samples under normal saline.

  20. Effect of collagen and elastin content on the burst pressure of human blood vessel seals formed with a bipolar tissue sealing system.

    PubMed

    Latimer, Cassandra A; Nelson, Meghan; Moore, Camille M; Martin, Kimberly E

    2014-01-01

    Bipolar devices are routinely used to seal blood vessels instead of sutures and clips. Recent work examining the impact of vascular proteins on bipolar seal performance found that collagen and elastin (CE) content within porcine arteries was a significant predictor of a vessel's burst pressure (VBPr). This study examined seal performance across a range of human blood vessels to investigate whether a similar relationship existed. In addition, we compared VBPr and CE content between porcine and human blood vessels. Our primary hypothesis is that higher collagen-to-elastin ratio will predict higher VBPr in human vasculature. In six cadavers, 185 blood vessels from nine anatomic locations were sealed using a bipolar electrosurgical system. A linear mixed model framework was used to evaluate the impact of vessel diameter and CE content on VBPr. The effect of CE ratio on VBPr is modified by vessel size, with CE ratio having larger influence on VBPr in smaller diameter vessels. Seal burst pressure of vessels 2-5 mm in diameter was significantly associated with their CE content. Comparison of average VBPr between species revealed porcine carotid and iliac arteries (440-670 mmHg) to be the best vessel types for predicting the seal strength of most human blood vessels (420-570 mmHg) examined. CE content significantly modified the seal strength of small to medium sized blood vessels but had limited impact on vessels >5 mm. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measuremore » of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.« less

  2. Wavelength dependence of the apparent diameter of retinal blood vessels

    NASA Astrophysics Data System (ADS)

    Park, Robert; Twietmeyer, Karen; Chipman, Russell; Beaudry, Neil; Salyer, David

    2005-04-01

    Imaging of retinal blood vessels may assist in the diagnosis and monitoring of diseases such as glaucoma, diabetic retinopathy, and hypertension. However, close examination reveals that the contrast and apparent diameter of vessels are dependent on the wavelength of the illuminating light. In this study multispectral images of large arteries and veins within enucleated swine eyes are obtained with a modified fundus camera by use of intravitreal illumination. The diameters of selected vessels are measured as a function of wavelength by cross-sectional analysis. A fixed scale with spectrally independent dimension is placed above the retina to isolate the chromatic effects of the imaging system and eye. Significant apparent differences between arterial and venous diameters are found, with larger diameters observed at shorter wavelengths. These differences are due primarily to spectral absorption in the cylindrical blood column.

  3. Heparin Stimulates Elastogenesis: Application to Silk-Based Vascular Grafts

    PubMed Central

    Baughman, Cassandra; Kaplan, David L.; Castellot, John J.

    2013-01-01

    With over 500,000 coronary artery bypass grafts (CABG) performed annually in the United States alone, there is a significant clinical need for a small diameter tissue engineered vascular graft. A principle goal in tissue engineering is to develop materials and growth conditions that encourage appropriate re-cellularization and extracellular matrix formation in vivo. A particular challenge in vascular tissue engineering results from the inability of adult cells to produce elastin, as its expression is developmentally limited. We investigated factors to stimulate elastogenesis in vitro, and found that heparin treatment of adult human vascular smooth muscle cells promoted the formation of elastic fibers. This effect was heparin-specific, and dependent on cell density and growth state. We then applied this information to a silk-based construct, and found that immobilized heparin showed essentially identical biological effects to that of soluble heparin. These findings indicate that heparinized vascular grafts may promote elastin formation and regulate restenosis, in addition to heparin’s well-established antithrombotic properties. Given the increase in elastin mRNA level and the increase in extracellular elastin present, our data suggests that there may be multiple levels of elastin regulation that are mediated by heparin treatment. PMID:21600981

  4. Cerebral Microvascular and Systemic Effects Following Intravenous Administration of the Perfluorocarbon Emulsion Perftoran

    PubMed Central

    Abutarboush, Rania; Saha, Biswajit K.; Mullah, Saad H.; Arnaud, Francoise G.; Haque, Ashraful; Aligbe, Chioma; Pappas, Georgina; Auker, Charles R.; McCarron, Richard M.; Moon-Massat, Paula F.; Scultetus, Anke H.

    2016-01-01

    Oxygen-carrying perfluorocarbon (PFC) fluids have the potential to increase tissue oxygenation during hypoxic states and to reduce ischemic cell death. Regulatory approval of oxygen therapeutics was halted due to concerns over vasoconstrictive side effects. The goal of this study was to assess the potential vasoactive properties of Perftoran by measuring brain pial arteriolar diameters in a healthy rat model. Perftoran, crystalloid (saline) or colloid (Hextend) solutions were administered as four sequential 30 min intravenous (IV) infusions, thus allowing an evaluation of cumulative dose-dependent effects. There were no overall changes in diameters of small-sized (<50 μm) pial arterioles within the Perftoran group, while both saline and Hextend groups exhibited vasoconstriction. Medium-sized arterioles (50–100 μm) showed minor (~8–9%) vasoconstriction within saline and Hextend groups and only ~5% vasoconstriction within the Perftoran group. For small- and medium-sized pial arterioles, the mean percent change in vessel diameters was not different among the groups. Although there was a tendency for arterial blood pressures to increase with Perftoran, pressures were not different from the other two groups. These data show that Perftoran, when administered to healthy anesthetized rats, does not cause additional vasoconstriction in cerebral pial arterioles or increase systemic blood pressure compared with saline or Hextend. PMID:27869709

  5. Cerebral Microvascular and Systemic Effects Following Intravenous Administration of the Perfluorocarbon Emulsion Perftoran.

    PubMed

    Abutarboush, Rania; Saha, Biswajit K; Mullah, Saad H; Arnaud, Francoise G; Haque, Ashraful; Aligbe, Chioma; Pappas, Georgina; Auker, Charles R; McCarron, Richard M; Moon-Massat, Paula F; Scultetus, Anke H

    2016-11-18

    Oxygen-carrying perfluorocarbon (PFC) fluids have the potential to increase tissue oxygenation during hypoxic states and to reduce ischemic cell death. Regulatory approval of oxygen therapeutics was halted due to concerns over vasoconstrictive side effects. The goal of this study was to assess the potential vasoactive properties of Perftoran by measuring brain pial arteriolar diameters in a healthy rat model. Perftoran, crystalloid (saline) or colloid (Hextend) solutions were administered as four sequential 30 min intravenous (IV) infusions, thus allowing an evaluation of cumulative dose-dependent effects. There were no overall changes in diameters of small-sized (<50 μm) pial arterioles within the Perftoran group, while both saline and Hextend groups exhibited vasoconstriction. Medium-sized arterioles (50-100 μm) showed minor (~8-9%) vasoconstriction within saline and Hextend groups and only ~5% vasoconstriction within the Perftoran group. For small- and medium-sized pial arterioles, the mean percent change in vessel diameters was not different among the groups. Although there was a tendency for arterial blood pressures to increase with Perftoran, pressures were not different from the other two groups. These data show that Perftoran, when administered to healthy anesthetized rats, does not cause additional vasoconstriction in cerebral pial arterioles or increase systemic blood pressure compared with saline or Hextend.

  6. beta(2)-adrenoceptor antagonist ICI 118,551 decreases pulmonary vascular tone in mice via a G(i/o) protein/nitric oxide-coupled pathway.

    PubMed

    Wenzel, Daniela; Knies, Ralf; Matthey, Michaela; Klein, Alexandra M; Welschoff, Julia; Stolle, Vanessa; Sasse, Philipp; Röll, Wilhelm; Breuer, Johannes; Fleischmann, Bernd K

    2009-07-01

    beta(2)-adrenoceptors are important modulators of vascular tone, particularly in the pulmonary circulation. Because neurohormonal activation occurs in pulmonary arterial hypertension, we have investigated the effect of different adrenergic vasoactive substances on tone regulation in large and small pulmonary arteries, as well as in systemic vessels of mice. We found that the beta(2)-adrenoceptor antagonist ICI 118,551 (ICI) evoked a decrease of vascular tone in large pulmonary arteries and reduced the sensitivity of pulmonary arteries toward different contracting agents, eg, norepinephrine, serotonin, or endothelin. ICI proved to act specifically on pulmonary vessels, because it shifted the dose-response curve of norepinephrine to the right in pulmonary arteries, whereas there was no effect in the aorta. Pharmacological experiments proved that the right shift of the norepinephrine dose-response curve by ICI was mediated via a beta(2)-adrenoceptor/G(i/o) protein-dependent pathway enhancing NO production in the endothelium; these results were corroborated in beta-adrenoceptor and endothelial NO synthase knockout mice where ICI had no effect. ICI increased vascular lumen diameter in lung sections and reduced pulmonary arterial pressure under normoxia and under hypoxia in the isolated perfused lung model. These effects were found to be physiologically relevant, because ICI specifically decreased pulmonary but not systemic blood pressure in vivo. Thus, the beta(2)-adrenoceptor antagonist ICI is a pulmonary arterial-specific vasorelaxant and, therefore, a potentially interesting novel therapeutic agent for the treatment of pulmonary arterial hypertension.

  7. Relative contributions from the ventricle and arterial tree to arterial pressure and its amplification: an experimental study

    PubMed Central

    Alastruey, Jordi; Chowienczyk, Phil; Rutten, Marcel C. M.; Segers, Patrick; Schaeffter, Tobias

    2017-01-01

    Arterial pressure is an important diagnostic parameter for cardiovascular disease. However, relative contributions of individual ventricular and arterial parameters in generating and augmenting pressure are not understood. Using a novel experimental arterial model, our aim was to characterize individual parameter contributions to arterial pressure and its amplification. A piston-driven ventricle provided programmable stroke profiles into various silicone arterial trees and a bovine aorta. Inotropy was varied in the ventricle, and arterial parameters modulated included wall thickness, taper and diameter, the presence of bifurcation, and a native aorta (bovine) versus silicone. Wave reflection at bifurcations was measured and compared with theory, varying parent-to-child tube diameter ratios, and branch angles. Intravascular pressure-tip wires and ultrasonic flow probes measured pressure and flow. Increasing ventricular inotropy independently augmented pressure amplification from 17% to 61% between the lower and higher systolic gradient stroke profiles in the silicone arterial network and from 10% to 32% in the bovine aorta. Amplification increased with presence of a bifurcation, decreasing wall thickness and vessel taper. Pulse pressure increased with increasing wall thickness (stiffness) and taper angle and decreasing diameter. Theoretical predictions of wave transmission through bifurcations werre similar to measurements (correlation: 0.91, R2 = 0.94) but underestimated wave reflection (correlation: 0.75, R2 = 0.94), indicating energy losses during mechanical wave reflection. This study offers the first comprehensive investigation of contributors to hypertensive pressure and its propagation throughout the arterial tree. Importantly, ventricular inotropy plays a crucial role in the amplification of peripheral pressure wave, which offers opportunity for noninvasive assessment of ventricular health. NEW & NOTEWORTHY The present study distinguishes contributions from cardiac and arterial parameters to elevated blood pressure and pressure amplification. Most importantly, it offers the first evidence that ventricular inotropy, an indicator of ventricular function, is an independent determinant of pressure amplification and could be measured with such established devices such as the SphygmoCor. PMID:28576835

  8. Relative contributions from the ventricle and arterial tree to arterial pressure and its amplification: an experimental study.

    PubMed

    Gaddum, Nicholas; Alastruey, Jordi; Chowienczyk, Phil; Rutten, Marcel C M; Segers, Patrick; Schaeffter, Tobias

    2017-09-01

    Arterial pressure is an important diagnostic parameter for cardiovascular disease. However, relative contributions of individual ventricular and arterial parameters in generating and augmenting pressure are not understood. Using a novel experimental arterial model, our aim was to characterize individual parameter contributions to arterial pressure and its amplification. A piston-driven ventricle provided programmable stroke profiles into various silicone arterial trees and a bovine aorta. Inotropy was varied in the ventricle, and arterial parameters modulated included wall thickness, taper and diameter, the presence of bifurcation, and a native aorta (bovine) versus silicone. Wave reflection at bifurcations was measured and compared with theory, varying parent-to-child tube diameter ratios, and branch angles. Intravascular pressure-tip wires and ultrasonic flow probes measured pressure and flow. Increasing ventricular inotropy independently augmented pressure amplification from 17% to 61% between the lower and higher systolic gradient stroke profiles in the silicone arterial network and from 10% to 32% in the bovine aorta. Amplification increased with presence of a bifurcation, decreasing wall thickness and vessel taper. Pulse pressure increased with increasing wall thickness (stiffness) and taper angle and decreasing diameter. Theoretical predictions of wave transmission through bifurcations werre similar to measurements (correlation: 0.91, R 2 = 0.94) but underestimated wave reflection (correlation: 0.75, R 2 = 0.94), indicating energy losses during mechanical wave reflection. This study offers the first comprehensive investigation of contributors to hypertensive pressure and its propagation throughout the arterial tree. Importantly, ventricular inotropy plays a crucial role in the amplification of peripheral pressure wave, which offers opportunity for noninvasive assessment of ventricular health. NEW & NOTEWORTHY The present study distinguishes contributions from cardiac and arterial parameters to elevated blood pressure and pressure amplification. Most importantly, it offers the first evidence that ventricular inotropy, an indicator of ventricular function, is an independent determinant of pressure amplification and could be measured with such established devices such as the SphygmoCor. Copyright © 2017 the American Physiological Society.

  9. [Anatomy study on micro transverse flap pedicled with superfical palmar branch of radial artery from palmar wrist].

    PubMed

    Zhao, Min; Tian, Dehu; Shao, Xinzhong; Li, Dacun; Li, Jianfeng; Liu, Jingda; Zhao, Liang; Li, Hailei; Wang, Xiaolei; Zhang, Wentong; Wu, Jinying; Yuan, Zuoxiong

    2013-07-01

    To study the anatomical basis of micro transverse flap pedicled with the superfical palmar branch of radial artery from the palmar wrist for using this free flap to repair soft tissue defect of the finger. Thirty-eight fresh upper limb specimens (22 males and 16 females; aged 26-72 years with an average of 36 years; at left and right sides in 19 limbs respectively) were dissected and observed under operating microscope. Two specimens were made into casting mould of artery with bones, and 2 specimens were injected with red emulsion in radial artery. Thirty-four specimens were injected with 1% gentian violet solution in the superfical palmar branch of the radial artery. A transverse oval flap in the palmar wrist was designed, the axis of the flap was the distal palmar crease. The origin, distribution, and anastomosis of the superfical palmar branch of the radial artery were observed. The superficial palmar branch of the radial artery was constantly existed, it usually arises from the main trunk of the radial artery, 1.09-3.60 cm to proximal styloid process of radius. There were about 2-5 branches between the origin and the tubercle of scaphoid bone. The origin diameter was 1.00-3.00 mm, and the distal diameter at the styloid process of radius was 1.00-2.90 mm. The venous return of flap passed through 2 routes, and the innervations of the flap mainly from the palmar cutaneous branch of the median nerve. The area of the flap was 4 cm x 2 cm-6 cm x 2 cm. The origin and courses of the superficial palmar branch of the radial artery is constant, and its diameter is similar to that of the digital artery. A transverse oval flap pedicled with the superfical palmar branch of radial artery in the palmar wrist can be designed to repair defects of the finger.

  10. Association of Severity of Coronary Artery Aneurysms in Patients With Kawasaki Disease and Risk of Later Coronary Events.

    PubMed

    Miura, Masaru; Kobayashi, Tohru; Kaneko, Tetsuji; Ayusawa, Mamoru; Fukazawa, Ryuji; Fukushima, Naoya; Fuse, Shigeto; Hamaoka, Kenji; Hirono, Keiichi; Kato, Taichi; Mitani, Yoshihide; Sato, Seiichi; Shimoyama, Shinya; Shiono, Junko; Suda, Kenji; Suzuki, Hiroshi; Maeda, Jun; Waki, Kenji; Kato, Hitoshi; Saji, Tsutomu; Yamagishi, Hiroyuki; Ozeki, Aya; Tomotsune, Masako; Yoshida, Makiko; Akazawa, Yohei; Aso, Kentaro; Doi, Shouzaburoh; Fukasawa, Yoshi; Furuno, Kenji; Hayabuchi, Yasunobu; Hayashi, Miyuki; Honda, Takafumi; Horita, Norihisa; Ikeda, Kazuyuki; Ishii, Masahiro; Iwashima, Satoru; Kamada, Masahiro; Kaneko, Masahide; Katyama, Hiroshi; Kawamura, Yoichi; Kitagawa, Atushi; Komori, Akiko; Kuraishi, Kenji; Masuda, Hiroshi; Matsuda, Shinichi; Matsuzaki, Satoshi; Mii, Sayaka; Miyamoto, Tomoyuki; Moritou, Yuji; Motoki, Noriko; Nagumo, Kiyoshi; Nakamura, Tsuneyuki; Nishihara, Eiki; Nomura, Yuichi; Ogata, Shohei; Ohashi, Hiroyuki; Okumura, Kenichi; Omori, Daisuke; Sano, Tetsuya; Suganuma, Eisuke; Takahashi, Tsutomu; Takatsuki, Shinichi; Takeda, Atsuhito; Terai, Masaru; Toyono, Manatomo; Watanabe, Kenichi; Watanabe, Makoto; Yamamoto, Masaki; Yamamura, Kenichiro

    2018-05-07

    Few studies with sufficient statistical power have shown the association of the z score of the coronary arterial internal diameter with coronary events (CE) in patients with Kawasaki disease (KD) with coronary artery aneurysms (CAA). To clarify the association of the z score with time-dependent CE occurrence in patients with KD with CAA. This multicenter, collaborative retrospective cohort study of 44 participating institutions included 1006 patients with KD younger than 19 years who received a coronary angiography between 1992 and 2011. The time-dependent occurrence of CE, including thrombosis, stenosis, obstruction, acute ischemic events, and coronary interventions, was analyzed for small (z score, <5), medium (z score, ≥5 to <10; actual internal diameter, <8 mm), and large (z score, ≥10 or ≥8 mm) CAA by the Kaplan-Meier method. The Cox proportional hazard regression model was used to identify risk factors for CE after adjusting for age, sex, size, morphology, number of CAA, resistance to initial intravenous immunoglobulin (IVIG) therapy, and antithrombotic medications. Of 1006 patients, 714 (71%) were male, 341 (34%) received a diagnosis before age 1 year, 501 (50%) received a diagnosis between age 1 and 5 years, and 157 (16%) received a diagnosis at age 5 years or older. The 10-year event-free survival rate for CE was 100%, 94%, and 52% in men (P < .001) and 100%, 100%, and 75% in women (P < .001) for small, medium, and large CAA, respectively. The CE-free rate was 100%, 96%, and 79% in patients who were not resistant to IVIG therapy (P < .001) and 100%, 96%, and 51% in patients who were resistant to IVIG therapy (P < .001), respectively. Cox regression analysis revealed that large CAA (hazard ratio, 8.9; 95% CI, 5.1-15.4), male sex (hazard ratio, 2.8; 95% CI, 1.7-4.8), and resistance to IVIG therapy (hazard ratio, 2.2; 95% CI, 1.4-3.6) were significantly associated with CE. Classification using the internal diameter z score is useful for assessing the severity of CAA in relation to the time-dependent occurrence of CE and associated factors in patients with KD. Careful management of CE is necessary for all patients with KD with CAA, especially men and IVIG-resistant patients with a large CAA.

  11. Intravital Förster resonance energy transfer imaging reveals elevated [Ca2+]i and enhanced sympathetic tone in femoral arteries of angiotensin II-infused hypertensive biosensor mice

    PubMed Central

    Wang, Youhua; Chen, Ling; Wier, W Gil; Zhang, Jin

    2013-01-01

    Artery narrowing in hypertension can only result from structural remodelling of the artery, or increased smooth muscle contraction. The latter may occur with, or without, increases in [Ca2+]i. Here, we sought to measure, in living hypertensive mice, possible changes in artery dimensions and/or [Ca2+]i, and to determine some of the mechanisms involved. Ca2+/calmodulin biosensor (Förster resonance energy transfer-based) mice were made hypertensive by s.c. infusion of angiotensin II (Ang II, 400 ng kg−1 min−1, 2–3 weeks). Intravital fluorescence microscopy was used to determine [Ca2+]i and outer diameter of surgically exposed, intact femoral artery (FA) of anaesthetized mice. Active contractile FA ‘tone’ was calculated from the basal-state diameter and the passive (i.e. Ca2+-free) diameter (PD). Compared to saline control, FAs of Ang II-infused mice had (1) ∼21% higher active tone and (2) ∼78 nm higher smooth muscle [Ca2+]i, but (3) the same PDs. The local Ang II receptor (AT1R) blocker losartan had negligible effect on tone or [Ca2+]i in control FAs, but reduced the basal tone by ∼9% in Ang II FAs. Both i.v. hexamethonium and locally applied prazosin abolished the difference in FA tone and [Ca2+]i, suggesting a dominant role of sympathetic nerve activity (SNA). Changes in diameter and [Ca2+]i in response to locally applied phenylephrine, Ang II, arginine vasopressin, elevated [K+]o and acetylcholine were not altered. In summary, FAs of living Ang II hypertensive mice have higher [Ca2+]i, and are more constricted, due, primarily, to elevated SNA and some increased arterial AT1R activation. Evidence of altered artery reactivity or remodeling was not found. PMID:23981717

  12. Intravital Förster resonance energy transfer imaging reveals elevated [Ca2+]i and enhanced sympathetic tone in femoral arteries of angiotensin II-infused hypertensive biosensor mice.

    PubMed

    Wang, Youhua; Chen, Ling; Wier, W Gil; Zhang, Jin

    2013-11-01

    Artery narrowing in hypertension can only result from structural remodelling of the artery, or increased smooth muscle contraction. The latter may occur with, or without, increases in [Ca(2+)]i. Here, we sought to measure, in living hypertensive mice, possible changes in artery dimensions and/or [Ca(2+)]i, and to determine some of the mechanisms involved. Ca(2+)/calmodulin biosensor (Förster resonance energy transfer-based) mice were made hypertensive by s.c. infusion of angiotensin II (Ang II, 400 ng kg(-1) min(-1), 2-3 weeks). Intravital fluorescence microscopy was used to determine [Ca(2+)]i and outer diameter of surgically exposed, intact femoral artery (FA) of anaesthetized mice. Active contractile FA 'tone' was calculated from the basal-state diameter and the passive (i.e. Ca(2+)-free) diameter (PD). Compared to saline control, FAs of Ang II-infused mice had (1) ∼21% higher active tone and (2) ∼78 nm higher smooth muscle [Ca(2+)]i, but (3) the same PDs. The local Ang II receptor (AT1R) blocker losartan had negligible effect on tone or [Ca(2+)]i in control FAs, but reduced the basal tone by ∼9% in Ang II FAs. Both i.v. hexamethonium and locally applied prazosin abolished the difference in FA tone and [Ca(2+)]i, suggesting a dominant role of sympathetic nerve activity (SNA). Changes in diameter and [Ca(2+)]i in response to locally applied phenylephrine, Ang II, arginine vasopressin, elevated [K(+)]o and acetylcholine were not altered. In summary, FAs of living Ang II hypertensive mice have higher [Ca(2+)]i, and are more constricted, due, primarily, to elevated SNA and some increased arterial AT1R activation. Evidence of altered artery reactivity or remodeling was not found.

  13. Anatomical and procedural determinants of ambulatory blood pressure lowering following catheter-based renal denervation using radiofrequency.

    PubMed

    Lauder, Lucas; Ewen, Sebastian; Tzafriri, Abraham R; Edelman, Elazer R; Cremers, Bodo; Kulenthiran, Saarraaken; Ukena, Christian; Linz, Dominik; Kindermann, Ingrid; Tsioufis, Costas; Scheller, Bruno; Böhm, Michael; Mahfoud, Felix

    2018-03-02

    Catheter-based renal sympathetic denervation (RDN) has been introduced to lower blood pressure (BP) and sympathetic activity in patients with uncontrolled hypertension with at best equivocal results. It has been postulated that anatomic and procedural elements introduce unaccounted variability and yet little is known of the impact of renal anatomy and procedural parameters on BP response to RDN. Anatomical parameters such as length and diameter were analyzed by quantitative vascular analysis and the prevalence of accessory renal arteries and renal artery disease were documented in 150 patients with resistant hypertension undergoing bilateral RDN using a mono-electrode radiofrequency catheter (Symplicity Flex, Medtronic). Accessory renal arteries and renal artery disease were present in 56 (37%) and 14 patients (9%), respectively. At 6-months, 24 h-ambulatory BP was reduced by 11/6 mm Hg (p < 0.001 for both). Change of systolic blood pressure (SBP) was not related to the presence of accessory renal arteries (p = 0.543) or renal artery disease (p = 0.598). Patients with at least one main renal artery diameter ≤ 4 mm had a more pronounced reduction of 24 h-ambulatory SBP compared to patients where both arteries were >4 mm (-19 vs. -10 mmHg; p = 0.038). Neither the length of the renal artery nor the number of RF ablations influenced 24 h-ambulatory BP reduction at 6 months. 24 h-ambulatory BP lowering was most pronounced in patients with smaller renal artery diameter but not related to renal artery length, accessory arteries or renal artery disease. Further, there was no dose-response relationship observed with increasing number of ablations. Because little is known of the impact of renal anatomy and procedural parameters on blood pressure (BP) response to renal denervation (RDN), anatomical and procedural data were analyzed in 150 patients undergoing bilateral RDN. BP lowering was most pronounced in patients with smaller renal artery diameter but not related to renal artery length, the presence of renal artery disease or accessory renal arteries. Further, there was no dose-response relationship observed with increasing number of ablations. Copyright © 2018. Published by Elsevier Inc.

  14. Pulmonary artery closure in combination with patch technique for treating congenital heart disease combined with large patent ductus arteriosus: A clinical study of 9 cases

    PubMed Central

    Wen, Bing; Yang, Junya; Liu, Huiruo; Jiao, Zhouyang; Zhao, Wenzeng

    2016-01-01

    Objective: To document clinical experience of treating congenital heart disease combined with large patent ductus arteriosus with pulmonary artery closure in combination with patch technique. Methods: Thirty-six patients (8 males and 28 females) who suffered from congenital heart disease and underwent hybrid surgery in the First Affiliated Hospital of Zhengzhou University from October 2010 to February 2014 were selected for this study. They aged 14 to 39 years and weighed 32.20 to 61.50 kg. Diameter of arterial duct was between 10 mm and 13 mm; 28 cases were tube type, 4 cases were funnel type and four cases were window type. All patients had moderate or severe pulmonary arterial hypertension; besides, there were 28 cases of ventricular septal defect, 16 cases of atrial septal defect, eight cases of aortic insufficiency, four cases of mitral stenosis and insufficiency and four cases of infectious endocarditis. Cardz Pulmonary Bypass (CPB) was established after chest was opened along the middle line. With the help of Transesophageal echocardiography, large patent ductus arteriosus was blocked off through pulmonary artery. Pulmonary artery was cut apart after blocking of heart. Large patent ductus arteriosus on the side of pulmonary artery was strengthened with autologous pericardial patch. Results: Of 36 patients, 32 patients had patent ductus arteriosus closure device and four patients had atrial septal defect closure device. Pulmonary arteries of 36 cases were all successfully closed. Systolic pressure declined after closure ((54.86±19.23) mmHg vs (96.05±23.07) mmHg, p<0.05); average pulmonary arterial pressure also declined after closure ((39.15±14.83) mmHg vs (72.88±15.76) mmHg, p<0.05). The patients were followed up for one to fifty one months (average 11.5 months). Compared to before surgery, left atrial diameter, left ventricular diameter and pulmonary artery diameter all narrowed after surgery. Besides, clinical symptoms were relieved and cardiac function of the patients also improved. Conclusion: Hybrid surgery is feasible and safe in treating patients with large patent ductus arteriosus and congenital heart disease, which decreases surgical problems, shortens surgical time and lowers the incidence of complications. PMID:27375685

  15. Pulmonary artery closure in combination with patch technique for treating congenital heart disease combined with large patent ductus arteriosus: A clinical study of 9 cases.

    PubMed

    Wen, Bing; Yang, Junya; Liu, Huiruo; Jiao, Zhouyang; Zhao, Wenzeng

    2016-01-01

    To document clinical experience of treating congenital heart disease combined with large patent ductus arteriosus with pulmonary artery closure in combination with patch technique. Thirty-six patients (8 males and 28 females) who suffered from congenital heart disease and underwent hybrid surgery in the First Affiliated Hospital of Zhengzhou University from October 2010 to February 2014 were selected for this study. They aged 14 to 39 years and weighed 32.20 to 61.50 kg. Diameter of arterial duct was between 10 mm and 13 mm; 28 cases were tube type, 4 cases were funnel type and four cases were window type. All patients had moderate or severe pulmonary arterial hypertension; besides, there were 28 cases of ventricular septal defect, 16 cases of atrial septal defect, eight cases of aortic insufficiency, four cases of mitral stenosis and insufficiency and four cases of infectious endocarditis. Cardz Pulmonary Bypass (CPB) was established after chest was opened along the middle line. With the help of Transesophageal echocardiography, large patent ductus arteriosus was blocked off through pulmonary artery. Pulmonary artery was cut apart after blocking of heart. Large patent ductus arteriosus on the side of pulmonary artery was strengthened with autologous pericardial patch. Of 36 patients, 32 patients had patent ductus arteriosus closure device and four patients had atrial septal defect closure device. Pulmonary arteries of 36 cases were all successfully closed. Systolic pressure declined after closure ((54.86±19.23) mmHg vs (96.05±23.07) mmHg, p<0.05); average pulmonary arterial pressure also declined after closure ((39.15±14.83) mmHg vs (72.88±15.76) mmHg, p<0.05). The patients were followed up for one to fifty one months (average 11.5 months). Compared to before surgery, left atrial diameter, left ventricular diameter and pulmonary artery diameter all narrowed after surgery. Besides, clinical symptoms were relieved and cardiac function of the patients also improved. Hybrid surgery is feasible and safe in treating patients with large patent ductus arteriosus and congenital heart disease, which decreases surgical problems, shortens surgical time and lowers the incidence of complications.

  16. SR high-speed K-edge subtraction angiography in the small animal (abstract)

    NASA Astrophysics Data System (ADS)

    Takeda, T.; Akisada, M.; Nakajima, T.; Anno, I.; Ueda, K.; Umetani, K.; Yamaguchi, C.

    1989-07-01

    To assess the ability of the high-speed K-edge energy subtraction system which was made at beamline 8C of Photon Factory, Tsukuba, we performed an animal experiment. Rabbits were used for the intravenous K-edge subtraction angiography. In this paper, the actual images of the artery obtained by this system, are demonstrated. The high-speed K-edge subtraction system consisted of movable silicon (111) monocrystals, II-ITV, and digital memory system. Image processing was performed by 68000-IP computer. The monochromatic x-ray beam size was 50×60 mm. Photon energy above and below iodine K edge was changed within 16 ms and 32 frames of images were obtained sequentially. The rabbits were anaesthetized by phenobarbital and a 5F catheter was inserted into inferior vena cava via the femoral vein. 1.5 ml/kg of contrast material (Conlaxin H) was injected at the rate of 0.5 ml/kg/s. TV images were obtained 3 s after the starting point of injection. By using this system, the clear K-edge subtracted images were obtained sequentially as a conventional DSA system. The quality of the images were better than that obtained by DSA. The dynamical blood flow was analyzed, and the best arterial image could be selected from the sequential images. The structures of aortic arch, common carotid arteries, right subclavian artery, and internal thoracic artery were obtained at the chest. Both common carotid arteries and vertebral arteries were recorded at the neck. The diameter of about 0.3-0.4 mm artery could be clearly revealed. The high-speed K-edge subtraction system demonstrates the very sharp arterial images clearly and dynamically.

  17. [Transperineal ultrasound imaging of the internal pudendal artery in arteriogenic erectile dysfunction].

    PubMed

    Povelitsa, E; Dosta, N I; Parhomenko, O V; Nitkin, D M; Shesternja, A M; Anichkin, V V

    2017-09-01

    To determine the practical and diagnostic value of transperineal ultrasound imaging of the internal pudendal artery (IPA) in patients with arteriogenic erectile dysfunction (ED). Transperineal IPA and penile Doppler ultrasonography was performed in 50 healthy young male volunteers aged 23.6+/-3.4 years without ED (IIEF-5 score of 21-22) and 60 patients with ED (IIEF-5 score of 6-18, mean age 49+/-4.6 years), including 30 men with prostate cancer (PCa) after comprehensive treatment and 30 patients with type 1 and type 2 diabetes mellitus. To determine the diagnostic value of the transperineal IPA imaging, the results were compared with the findings of magnetic resonance or contrast-enhanced dynamic CT angiography of the iliac arteries. In all healthy men no abnormalities were found in the perineal primary arterial blood flow, in 100% of cases perineal branch of IPA was rectilinear, while patients with arteriogenic ED had low IPA and penile peak systolic blood flow velocity (<0.05), pathologically altered type of blood flow and non-rectilinear course of IPA, stenosis and occlusion in the pelvic and extrapelvic branches of IPA. When comparing the findings of IPA Doppler ultrasound and angiography studies of the small pelvis in healthy men, they completely matched, showing satisfactory arterial IPA perfusion, absence of stenoses or occlusions. Sensitivity and specificity of the transperineal IPA ultrasound imaging were 95% and 90%, respectively. Transperineal IPA ultrasound imaging allows to assess the important morphometric features of the perineal branches of IPA - the arterial diameter, the response to stimulation, the course of the artery, the type of arterial blood flow, the presence or absence of arterial stenoses and occlusions, and to measure peak systolic blood flow velocity.

  18. Analysis by early angiography of right internal thoracic artery grafting via the transverse sinus : predictors of graft failure.

    PubMed

    Ura, M; Sakata, R; Nakayama, Y; Arai, Y; Oshima, S; Noda, K

    2000-02-15

    There has been debate regarding whether technically demanding right internal thoracic artery (RITA) grafting via the transverse sinus can be extensively applied to patients in high-risk groups, such as patients with a small body size, elderly patients, and woman with relatively smaller coronary artery and internal thoracic artery (ITA) diameters. Of the 1456 patients who underwent isolated coronary artery bypass grafting between January 1989 and December 1998 at Kumamoto Central Hospital, 393 patients (mean age, 62.4+/-9.0 years) with the RITA anastomosed to the major branches of the circumflex artery were studied. Left ITA grafting was performed in 384 patients, and in 369, the in situ left ITA was anastomosed to the left anterior descending coronary artery using standard methods. Early postoperative angiography was performed in 381 patients. The RITA was occluded in 4 patients, and string-like artery and significant stenosis were present in 11 and 7 patients, respectively; RITA graft patency was thus 94.1%. Of the preoperative variables and angiographic data, simple and multiple logistic regression analyses identified decreased severity of native stenosis, diffuse sclerosis of native vessels, and residual side branches of the ITA as independent predictors of nonfunctional grafts. The method of ITA grafting did not influence the patency of the graft. The excellent patency rate demonstrated by this study, the largest angiographic study to date of RITA grafting via the transverse sinus, indicates that this technique can provide reliable revascularization of the left ventricle and that it has the potential to be applied to a wide variety of patients with diseased circumflex arteries.

  19. An in vitro study of cryopreserved and fresh human arteries: a comparison with ePTFE prostheses and human arteries studied non-invasively in vivo.

    PubMed

    Armentano, Ricardo L; Santana, Daniel Bia; Cabrera Fischer, Edmundo I; Graf, Sebastián; Cámpos, Héctor Pérez; Germán, Yanina Zócalo; Carmen Saldías, Maria Del; Alvarez, Inés

    2006-02-01

    The surgical options in arterial reconstruction are: the use of autologous arteries; autologous veins; or expanded polytetrafluoroethylene (ePTFE) grafts. However, the development of intimal hyperplasia when using veins or ePTFE grafts has been associated with graft failure. Since autologous arteries are not always available, the use of cryopreserved arteries has to be considered. The aims of this study were: (a) to compare the viscoelastic properties of stored cryopreserved arteries and fresh arteries by in vitro analysis; and (b) to compare the viscoelastic properties of arteries measured non-invasively in normotensive patients, with fresh arteries, cryopreserved arteries, and ePTFE segments. The viscoelastic studies were performed in normotensive patients using stress-strain analysis with non-invasive measurement of pressure and diameter in the common carotid artery, and in vitro measurements of pressure and diameter in arteries and prostheses. The in vitro studies showed that the elastic modulus (E), viscous modulus (eta), Stiffness Index (SI), Peterson modulus (Ep), and the pulse wave velocity (PWV) values for human cryopreserved carotid arteries were similar to the values obtained non-invasively in normotensive subjects (P>0.05) and to human fresh vessels (P>0.05). In vitro, the SI, Ep, PWV, and E values of ePTFE were significantly higher than the observed values in subjects and with fresh and cryopreserved arteries (P<0.05); on the other hand the ePTFE eta values were the lowest (P<0.05). We concluded that cryopreserved arteries have similar viscoelastic properties to those obtained in vivo in the arteries of normotensive subjects and in vitro in fresh arteries. Consequently, we conclude that the cryopreservation procedure does not modify the mechanical properties of the arterial wall.

  20. Splenic artery ligature associated with endoscopic banding for schistosomal portal hypertension.

    PubMed

    Colaneri, Renata Potonyacz; Coelho, Fabrício Ferreira; de Cleva, Roberto; Perini, Marcos Vinícius; Herman, Paulo

    2014-11-28

    To propose a less invasive surgical treatment for schistosomal portal hypertension. Ten consecutive patients with hepatosplenic schistosomiasis and portal hypertension with a history of upper gastrointestinal hemorrhage from esophageal varices rupture were evaluated in this study. Patients were subjected to a small supraumbilical laparotomy with the ligature of the splenic artery and left gastric vein. During the procedure, direct portal vein pressure before and after the ligatures was measured. Upper gastrointestinal endoscopy was performed at the 30(th) postoperative day, when esophageal varices diameter were measured and band ligature performed. During follow-up, other endoscopic procedures were performed according to endoscopy findings. There was no intra-operative mortality and all patients had confirmed histologic diagnoses of schistosomal portal hypertension. During the immediate postoperative period, two of the ten patients had complications, one characterized by a splenic infarction, and the other by an incision hematoma. Mean hospitalization time was 4.1 d (range: 2-7 d). Pre- and post-operative liver function tests did not show any significant changes. During endoscopy thirty days after surgery, a decrease in variceal diameters was observed in seven patients. During the follow-up period (57-72 mo), endoscopic therapy was performed and seven patients had their varices eradicated. Considering the late postoperative evaluation, nine patients had a decrease in variceal diameters. A mean of 3.9 endoscopic banding sessions were performed per patient. Two patients presented bleeding recurrence at the late postoperative period, which was controlled with endoscopic banding in one patient due to variceal rupture and presented as secondary to congestive gastropathy in the other patient. Both bleeding episodes were of minor degree with no hemodynamic consequences or need for blood transfusion. Ligature of the splenic artery and left gastric vein with supraumbilical laparotomy is a promising and less invasive method for treating presinusoidal schistosomiasis portal hypertension.

  1. Small artery elasticity predicts future cardiovascular events in chinese patients with angiographic coronary artery disease.

    PubMed

    Wan, Zhaofei; Liu, Xiaojun; Wang, Xinhong; Liu, Fuqiang; Liu, Weimin; Wu, Yue; Pei, Leilei; Yuan, Zuyi

    2014-04-01

    Arterial elasticity has been shown to predict cardiovascular disease (CVD) in apparently healthy populations. The present study aimed to explore whether arterial elasticity could predict CVD events in Chinese patients with angiographic coronary artery disease (CAD). Arterial elasticity of 365 patients with angiographic CAD was measured. During follow-up (48 months; range 6-65), 140 CVD events occurred (including 34 deaths). Univariate Cox analysis demonstrated that both large arterial elasticity and small arterial elasticity were significant predictors of CVD events. Multivariate Cox analysis indicated that small arterial elasticity remained significant. Kaplan-Meier analysis showed that the probability of having a CVD event/CVD death increased with a decrease of small arterial elasticity (P < .001, respectively). Decreased small arterial elasticity independently predicts the risk of CVD events in Chinese patients with angiographic CAD.

  2. Advanced wood- and bio-composites : enhanced performance and sustainability

    Treesearch

    Jerrold E. Winandy

    2006-01-01

    Use of wood-based-composites technology to create value-added commodities and traditional construction materials is generally accepted worldwide. Engineered wood- and lignocellulosic-composite technologies allow users to add considerable value to a diverse number of wood- and lignocellulosic feedstocks including small-diameter timber, fast plantation-grown timber,...

  3. Image quality phantom and parameters for high spatial resolution small-animal SPECT

    NASA Astrophysics Data System (ADS)

    Visser, Eric P.; Harteveld, Anita A.; Meeuwis, Antoi P. W.; Disselhorst, Jonathan A.; Beekman, Freek J.; Oyen, Wim J. G.; Boerman, Otto C.

    2011-10-01

    At present, generally accepted standards to characterize small-animal single photon emission tomographs (SPECT) do not exist. Whereas for small-animal positron emission tomography (PET), the NEMA NU 4-2008 guidelines are available, such standards are still lacking for small-animal SPECT. More specifically, a dedicated image quality (IQ) phantom and corresponding IQ parameters are absent. The structures of the existing PET IQ phantom are too large to fully characterize the sub-millimeter spatial resolution of modern multi-pinhole SPECT scanners, and its diameter will not fit into all scanners when operating in high spatial resolution mode. We therefore designed and constructed an adapted IQ phantom with smaller internal structures and external diameter, and a facility to guarantee complete filling of the smallest rods. The associated IQ parameters were adapted from NEMA NU 4. An additional parameter, effective whole-body sensitivity, was defined since this was considered relevant in view of the variable size of the field of view and the use of multiple bed positions as encountered in modern small-animal SPECT scanners. The usefulness of the phantom was demonstrated for 99mTc in a USPECT-II scanner operated in whole-body scanning mode using a multi-pinhole mouse collimator with 0.6 mm pinhole diameter.

  4. Brachial artery vasodilatation during prolonged lower limb exercise: role of shear rate

    PubMed Central

    Padilla, Jaume; Simmons, Grant H.; Vianna, Lauro C.; Davis, Michael J.; Laughlin, M. Harold; Fadel, Paul J.

    2012-01-01

    We recently observed a marked increase in brachial artery (BA) diameter during prolonged leg cycling exercise. The purpose of the present study was to test the hypothesis that this increase in BA diameter during lower limb exercise is shear stress mediated. Accordingly, we determined whether recapitulation of cycling-induced BA shear rate with forearm heating, a known stimulus evoking shear-induced conduit artery dilatation, would elicit comparable profiles and magnitudes of BA vasodilatation to those observed during cycling. In 12 healthy men, BA diameter and blood velocity were measured simultaneously using Doppler ultrasonography at baseline and every 5 min during 60 min of either steady-state semi-recumbent leg cycling (120 W) or forearm heating. At the onset of cycling, the BA diameter was reduced (−3.9 ± 1.2% at 5 min; P < 0.05), but it subsequently increased throughout the remainder of the exercise bout (+15.1 ± 1.6% at 60 min; P < 0.05). The increase in BA diameter during exercise was accompanied by an approximately 2.5-fold rise in BA mean shear rate (P < 0.05). Similar increases in BA mean shear with forearm heating elicited an equivalent magnitude of BA vasodilatation to that observed during cycling (P > 0.05). Herein, we found that in the absence of exercise the extent of the BA vasodilator response was reproduced when the BA was exposed to comparable magnitudes of shear rate via forearm heating. These results are consistent with the hypothesis that shear stress plays a key role in signalling brachial artery vasodilatation during dynamic leg exercise. PMID:21784788

  5. Hepatic Hemangiomas Alter Morphometry and Impair Hemodynamics of the Abdominal Aorta and Primary Branches From Computer Simulations.

    PubMed

    Yin, Xiaoping; Huang, Xu; Li, Qiao; Li, Li; Niu, Pei; Cao, Minglu; Guo, Fei; Li, Xuechao; Tan, Wenchang; Huo, Yunlong

    2018-01-01

    Background: The formation of hepatic hemangiomas (HH) is associated with VEGF and IL-7 that alter conduit arteries and small arterioles. To our knowledge, there are no studies to investigate the effects of HH on the hemodynamics in conduit arteries. The aim of the study is to perform morphometric and hemodynamic analysis in abdominal conduit arteries and bifurcations of HH patients and controls. Methods: Based on morphometry reconstructed from CT images, geometrical models were meshed with prismatic elements for the near wall region and tetrahedral and hexahedral elements for the core region. Simulations were performed for computation of the non-Newtonian blood flow using the Carreau-Yasuda model, based on which multiple hemodynamic parameters were determined. Results: There was an increase of the lumen size, diameter ratio, and curvature in the abdominal arterial tree of HH patients as compared with controls. This significantly increased the surface area ratio of low time-averaged wall shear stress (i.e., SAR-TAWSS [Formula: see text] 100%) (24.1 ± 7.9 vs. 5 ± 6%, 11.6 ± 12.8 vs. < 0.1%, and 44.5 ± 9.2 vs. 21 ± 24% at hepatic bifurcations, common hepatic arteries, and abdominal aortas, respectively, between HH and control patients). Conclusions: Morphometric changes caused by HH significantly deteriorated the hemodynamic environment in abdominal conduit arteries and bifurcations, which could be an important risk factor for the incidence and progression of vascular diseases.

  6. Computational fluid dynamic evaluation of the side-to-side anastomosis for arteriovenous fistula.

    PubMed

    Hull, Jeffrey E; Balakin, Boris V; Kellerman, Brad M; Wrolstad, David K

    2013-07-01

    The goal of this research was to compare side-to-side (STS) and end-to-side (ETS) anastomoses in a computer model of the arteriovenous fistula with computational fluid dynamic analysis. A matrix of 17 computer arteriovenous fistula models (SolidWorks, Dassault Systèmes, France) of artery-vein pairs (3-mm-diameter artery + 3-mm-diameter vein and 4-mm-diameter artery +6-mm-diameter vein elliptical anastomoses) in STS, 45° ETS, and 90° ETS configurations with cross-sectional areas (CSAs) of 3.5 to 18.8 mm(2) were evaluated with computational fluid dynamic software (STAR-CCM+; CD-adapco, Melville, NY) in simulations at defined flow rates from 600 to 1200 mL/min and mean arterial pressures of 50 to 140 mm Hg. Models and configurations were evaluated for pressure drop across the anastomosis, arterial inflow, venous outflow, arterial outflow, velocity vector, and wall shear stress (WSS) profile. Pressure drop across the anastomosis was inversely proportional to anastomotic CSA and to venous outflow and was proportional to arterial inflow. Pressure drop was greater in 3 + 3 models than in 4 + 6 STS models; 90° ETS configurations had the lowest pressure drops and were nearly identical, whereas 45° ETS configurations had the highest pressure drops. Venous outflow in the 4 + 6 model in STS configurations, evaluated at 100 mm Hg arterial inflow pressure, was 390, 592, 610, and 886 mL/min in anastomotic CSAs of 3.5, 5.3, 7.1, and 18.8 mm(2), respectively, and was similar in 90° ETS (609 and 908 mL/min) and lower in 45° ETS (534 and 562 mL/min) configurations at CSAs of 5.3 and 18.8 mm(2). The mean increase in venous outflow was 69 mL/min (range, -59 to 134) between 3 + 3 and 4 + 6 models at 100 mm Hg arterial inflow. The most uniform WSS profile occurs in STS anastomoses followed by 45° ETS and then 90° ETS anastomoses. The STS and 90° ETS anastomoses have high venous outflow and a tendency toward reversed arterial outflow. The 45° ETS anastomosis has reduced venous outflow but resists reversed arterial outflow. The STS anastomosis has more uniform WSS characteristics compared with the 45° and 90° ETS anastomoses. Copyright © 2013 Society for Vascular Surgery. Published by Mosby, Inc. All rights reserved.

  7. Pulsed liquid microjet for intravascular injection

    NASA Astrophysics Data System (ADS)

    Palanker, Daniel V.; Fletcher, Daniel A.; Miller, Jason; Huie, Philip; Marmor, Michael; Blumenkranz, Mark S.

    2002-06-01

    Occlusions of the retinal veins and arteries are associated with common diseases such as hypertension and arteriosclerosis and usually cause severe and irreversible loss of vision. Treatments for these vascular diseases have been unsatisfactory to date in part because of the difficulty of delivering thrombolytic drugs locally within the eye. In this article we describe a pulsed liquid microjet for minimally invasive intra-vascular drug delivery. The microjet is driven by a vapor bubble following an explosive evaporation of saline, produced by a microsecond-long electric discharge in front of the 25 micrometers electrode inside the micronozzle. Expansion of the transient vapor bubble produces a water jet with a diameter equal to the diameter of the nozzle, and with a velocity and duration that are controlled by the pulse energy. We found that fluid could be injected through the wall of a 60-micrometers -diameter artery in choriallantoic membrane using a 15-micrometers diameter liquid jet traveling at more than 60 m/s. Histological analysis of these arteries showed that the width of the perforation is limited to the diameter of the micronozzle, and the penetration depth of the jet is controlled by the discharge energy. The pulsed liquid microjet offers a promising technique for precise and needle-free intravascular delivery of thrombolytic drugs for localized treatment of retinal vascular occlusions.

  8. Hypertension - overview

    MedlinePlus Videos and Cool Tools

    If left untreated, hypertension can lead to the thickening of arterial walls causing its lumen, or blood passage way, to narrow in diameter. ... the narrowed arterial openings. In addition, people with hypertension may be more susceptible to stroke.

  9. Relation between digital peripheral arterial tonometry and brachial artery ultrasound measures of vascular function in patients with coronary artery disease and in healthy volunteers.

    PubMed

    Lee, Craig R; Bass, Almasa; Ellis, Kyle; Tran, Bryant; Steele, Savanna; Caughey, Melissa; Stouffer, George A; Hinderliter, Alan L

    2012-03-01

    Digital peripheral arterial tonometry (PAT) is an emerging, noninvasive method to assess vascular function. The physiology underlying this phenotype, however, remains unclear. Therefore, we evaluated the relation between digital PAT and established brachial artery ultrasound measures of vascular function under basal conditions and after reactive hyperemia. Using a cross-sectional study design, digital PAT and brachial artery ultrasonography with pulsed wave Doppler were simultaneously completed at baseline and after reactive hyperemia in both those with established coronary artery disease (n = 99) and healthy volunteers with low cardiovascular disease risk (n = 40). Under basal conditions, the digital pulse volume amplitude demonstrated a significant positive correlation with the brachial artery velocity-time integral that was independent of the arterial diameter, in both the healthy volunteer (r(s) = 0.64, p <0.001) and coronary artery disease (r(s) = 0.63, p <0.001) cohorts. Similar positive relations were observed with the baseline brachial artery blood flow velocity and blood flow. In contrast, no relation between the reactive hyperemia-evoked digital PAT ratio and either brachial artery flow-mediated dilation or shear stress was observed in either cohort (p = NS). In conclusion, these findings demonstrate that the digital PAT measures of vascular function more closely reflect basal blood flow in the brachial artery than reactive hyperemia-induced changes in the arterial diameter or flow velocity, and the presence of vascular disease does not modify the physiology underlying the digital PAT phenotype. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. The effect of proximal anastomosis on the expansion rate of a dilated ascending aorta in coronary artery bypass surgery: a prospective study

    PubMed Central

    Balcı, Ahmet Yavuz; Vural, Unsal; Özdemir, MD Fatih; Kızılay, Mehmet; Şenocak, Mutlu; Kayacıoğlu, Ilyas; Yekeler, Ibrahim; Aksoy, Rezan; Satılmış,, Seçkin; Şaşkın, Huseyin

    2017-01-01

    Summary Background: This study was designed to determine the short- and long-term effects of proximal aortic anastomosis, performed during isolated coronary artery bypass grafting (CABG) in patients with dilatation of the ascending aorta who did not require surgical intervention. Methods: The study was performed on 192 (38 female and 160 male patients; mean age, 62.1 ± 9.2 years; range, 42–80 years) patients with dilatation of the ascending aorta who underwent CABG surgery between 1 June 2006 and 31 May 2014. In group 1 (n = 114), the saphenous vein and left internal mammarian artery grafts were used, and proximal anastomosis was performed on the ascending aorta. In group 2 (n = 78), left and right internal mammarian artery grafts were used, and proximal aortic anastomosis was not performed. Pre-operatively and in the first and third years postoperatively, the ascending aortic diameter was measured and recorded using transthoracic echocardiography at four different regions (annulus, sinus of Valsalva, sinotubular junction and tubular aorta). Results: A statistically significant difference was found between the groups for the number of grafts used and the duration of aortic cross-clamping and cardiopulmonary bypass. No significant intergroup difference was seen for the mean diameter of the ascending aorta (p > 0.05). Annual changes in the aortic diameter were found to be extremely significantly different in both groups (p = 0.0001). Mean values of the aortic diameter at the level of the sinotubular junction and tubular ascending aorta, mean aortic diameters (p = 0.002 and p = 0.0001, respectively), annual increase in diameter (p = 0.0001 and p = 0.0001, respectively), and mean annual difference in diameter (p = 0.0001 and p = 0.0001, respectively) at one and three years postoperatively were statistically significantly different between the groups. Conclusion: In patients with ascending aortic dilatation who did not require surgical intervention and who had proximal anastomosis of the ascending aorta and underwent only CABG, we detected statistically significant increases in the diameter of the sinotubular junction and tubular aorta up to three years postoperatively. PMID:27701487

  11. The effect of proximal anastomosis on the expansion rate of a dilated ascending aorta in coronary artery bypass surgery: a prospective study.

    PubMed

    Yavuz Balci, Ahmet; Vural, Unsal; Aksoy, Rezan; Özdemir, M Fatih; Satilmiş, Seçkin; Kizilay, Mehmet; Şenocak, Mutlu; Şaşkin, Huseyin; Kayacioğlu, Ilyas; Yekeler, Ibrahim

    This study was designed to determine the short- and long-term effects of proximal aortic anastomosis, performed during isolated coronary artery bypass grafting (CABG) in patients with dilatation of the ascending aorta who did not require surgical intervention. The study was performed on 192 (38 female and 160 male patients; mean age, 62.1 ± 9.2 years; range, 42-80 years) patients with dilatation of the ascending aorta who underwent CABG surgery between 1 June 2006 and 31 May 2014. In group 1 (n = 114), the saphenous vein and left internal mammarian artery grafts were used, and proximal anastomosis was performed on the ascending aorta. In group 2 (n = 78), left and right internal mammarian artery grafts were used, and proximal aortic anastomosis was not performed. Pre-operatively and in the first and third years postoperatively, the ascending aortic diameter was measured and recorded using transthoracic echocardiography at four different regions (annulus, sinus of Valsalva, sinotubular junction and tubular aorta). A statistically significant difference was found between the groups for the number of grafts used and the duration of aortic cross-clamping and cardiopulmonary bypass. No significant intergroup difference was seen for the mean diameter of the ascending aorta (p > 0.05). Annual changes in the aortic diameter were found to be extremely significantly different in both groups (p = 0.0001). Mean values of the aortic diameter at the level of the sinotubular junction and tubular ascending aorta, mean aortic diameters (p = 0.002 and p = 0.0001, respectively), annual increase in diameter (p = 0.0001 and p = 0.0001, respectively), and mean annual difference in diameter (p = 0.0001 and p = 0.0001, respectively) at one and three years postoperatively were statistically significantly different between the groups. In patients with ascending aortic dilatation who did not require surgical intervention and who had proximal anastomosis of the ascending aorta and underwent only CABG, we detected statistically significant increases in the diameter of the sinotubular junction and tubular aorta up to three years postoperatively.

  12. CE-MRA for follow-up of aneurysms post stent-assisted coiling.

    PubMed

    Agid, R; Schaaf, M; Farb, Ri

    2012-09-01

    This study compared the accuracy of contrast-enhanced MR angiography (CE-MRA) to intra-arterial cerebral angiography (IA-DSA) for assessment of intracranial aneurysms after stent-assisted coiling and to check if the presence of a stent in the parent artery diminishes the accuracy of CE-MRA. Consecutive patients with cerebral aneurysms treated by stent-assisted coiling were evaluated retrospectively. Matching follow-up CE-MRA and IA-DSA were evaluated separately. Evaluation included the presence of aneurysmal remnant, patency and stenosis of parent artery. Twenty-seven patients with 28 aneurysms and 33 matched CE-MRA and IA-DSA studies were evaluated. Nineteen aneurysmal remnants were seen on CE-MRA and 16 on IA-DSA. CE-MRA diagnosed three aneurysmal remnants not appreciated on IA-DSA. Five other remnants were larger on CE-MRA than IA-DSA. None of the remnants were missed on CE-MRA. Parent arteries were patent on both modalities. CE-MRA showed false stenosis of the stented artery in six cases and exaggerated stenosis in two. In 18 cases, CE-MRA showed a short focal "pseudo-stenosis" where the stent's marker bands were located. This was noted whenever the stent's marker bands were located in an artery with luminal diameter ≤2 mm and was called "marker band effect". CE-MRA is an accurate technique for follow-up of aneurysms post stent-assisted coiling with excellent depiction of remnants in spite of the presence of a stent. Apparent stenosis of the stented parent artery on CE-MRA is often false or exaggerated. "Marker band effect" should be recognized as an artifact that appears when stent's marker bands are in a small artery.

  13. CE-MRA for Follow-up of Aneurysms Post Stent-Assisted Coiling

    PubMed Central

    Agid, R.; Schaaf, M.; Farb, RI.

    2012-01-01

    Summary This study compared the accuracy of contrast-enhanced MR angiography (CE-MRA) to intra-arterial cerebral angiography (IA-DSA) for assessment of intracranial aneurysms after stent-assisted coiling and to check if the presence of a stent in the parent artery diminishes the accuracy of CE-MRA. Consecutive patients with cerebral aneurysms treated by stent-assisted coiling were evaluated retrospectively. Matching follow-up CE-MRA and IA-DSA were evaluated separately. Evaluation included the presence of aneurysmal remnant, patency and stenosis of parent artery. Twenty-seven patients with 28 aneurysms and 33 matched CE-MRA and IA-DSA studies were evaluated. Nineteen aneurysmal remnants were seen on CE-MRA and 16 on IA-DSA. CE-MRA diagnosed three aneurysmal remnants not appreciated on IA-DSA. Five other remnants were larger on CE-MRA than IA-DSA. None of the remnants were missed on CE-MRA. Parent arteries were patent on both modalities. CE-MRA showed false stenosis of the stented artery in six cases and exaggerated stenosis in two. In 18 cases, CE-MRA showed a short focal “pseudo-stenosis” where the stent’s marker bands were located. This was noted whenever the stent’s marker bands were located in an artery with luminal diameter ≤2 mm and was called “marker band effect”. CE-MRA is an accurate technique for follow-up of aneurysms post stent-assisted coiling with excellent depiction of remnants in spite of the presence of a stent. Apparent stenosis of the stented parent artery on CE-MRA is often false or exaggerated. “Marker band effect” should be recognized as an artifact that appears when stent’s marker bands are in a small artery. PMID:22958765

  14. Coronary artery wall imaging in mice using osmium tetroxide and micro-computed tomography (micro-CT).

    PubMed

    Pai, Vinay M; Kozlowski, Megan; Donahue, Danielle; Miller, Elishiah; Xiao, Xianghui; Chen, Marcus Y; Yu, Zu-Xi; Connelly, Patricia; Jeffries, Kenneth; Wen, Han

    2012-05-01

    The high spatial resolution of micro-computed tomography (micro-CT) is ideal for 3D imaging of coronary arteries in intact mouse heart specimens. Previously, micro-CT of mouse heart specimens utilized intravascular contrast agents that hardened within the vessel lumen and allowed a vascular cast to be made. However, for mouse coronary artery disease models, it is highly desirable to image coronary artery walls and highlight plaques. For this purpose, we describe an ex vivo contrast-enhanced micro-CT imaging technique based on tissue staining with osmium tetroxide (OsO(4) ) solution. As a tissue-staining contrast agent, OsO(4) is retained in the vessel wall and surrounding tissue during the fixation process and cleared from the vessel lumens. Its high X-ray attenuation makes the artery wall visible in CT. Additionally, since OsO(4) preferentially binds to lipids, it highlights lipid deposition in the artery wall. We performed micro-CT of heart specimens of 5- to 25-week-old C57BL/6 wild-type mice and 5- to 13-week-old apolipoprotein E knockout (apoE(-/-) ) mice at 10 μm resolution. The results show that walls of coronary arteries as small as 45 μm in diameter are visible using a table-top micro-CT scanner. Similar image clarity was achieved with 1/2000th the scan time using a synchrotron CT scanner. In 13-week-old apoE mice, lipid-rich plaques are visible in the aorta. Our study shows that the combination of OsO(4) and micro-CT permits the visualization of the coronary artery wall in intact mouse hearts. Published 2012. This article is a US Government work and is in the public domain in the USA. Journal of Anatomy © 2012 Anatomical Society.

  15. Coronary artery wall imaging in mice using osmium tetroxide and micro-computed tomography (micro-CT)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pai, Vinay M.; Kozlowski, Megan; Donahue, Danielle

    2012-05-10

    The high spatial resolution of micro-computed tomography (micro-CT) is ideal for 3D imaging of coronary arteries in intact mouse heart specimens. Previously, micro-CT of mouse heart specimens utilized intravascular contrast agents that hardened within the vessel lumen and allowed a vascular cast to be made. However, for mouse coronary artery disease models, it is highly desirable to image coronary artery walls and highlight plaques. For this purpose, we describe an ex vivo contrast-enhanced micro-CT imaging technique based on tissue staining with osmium tetroxide (OsO{sub 4}) solution. As a tissue-staining contrast agent, OsO{sub 4} is retained in the vessel wall andmore » surrounding tissue during the fixation process and cleared from the vessel lumens. Its high X-ray attenuation makes the artery wall visible in CT. Additionally, since OsO{sub 4} preferentially binds to lipids, it highlights lipid deposition in the artery wall. We performed micro-CT of heart specimens of 5- to 25-week-old C57BL/6 wild-type mice and 5- to 13-week-old apolipoprotein E knockout (apoE{sup -/-}) mice at 10 {mu}m resolution. The results show that walls of coronary arteries as small as 45 {mu}m in diameter are visible using a table-top micro-CT scanner. Similar image clarity was achieved with 1/2000th the scan time using a synchrotron CT scanner. In 13-week-old apoE mice, lipid-rich plaques are visible in the aorta. Our study shows that the combination of OsO{sub 4} and micro-CT permits the visualization of the coronary artery wall in intact mouse hearts.« less

  16. Hemodynamics of the renal artery ostia with implications for their structural development and efficiency of flow.

    PubMed

    McIntosh, William H; Ozturk, Mesude; Down, Linden A; Papavassiliou, Dimitrios V; O'Rear, Edgar A

    2015-01-01

    Energy losses at tube or blood vessel orifices depend on the extent of flare as measured by the dimensionless ratio of the fillet radius of curvature to diameter (r/D). The goal of this study was to assess the effect of ostial fillet radii on energy losses at the aorta-renal artery junctions since as much as a quarter of cardiac output passes through the kidneys. Pressure loss coefficients K for the renal artery ostia as a function of r/D have been determined for representative anatomical variants using finite volume simulations. Estimates of fillet radii in humans from image analysis were employed in simulations for comparison of loss coefficients. Values for K drop 45% as r/D increases over the range 0-1.3. Image analysis indicates that the ostia are not symmetric in humans with (r/D)superior much larger than (r/D)inferior. Simulations show the loss coefficient depends almost entirely on the superior fillet radius. Superior fillet radii for both renal arteries are similar to the optimal value to reduce energy losses while the inferior radii are not. Ostial asymmetry may have been induced by higher levels of shear stress present on the superior portion of a developing symmetric ostium of small r/D.

  17. Coronary artery dimensions: Iranian population versus Indo-Asians and Caucasians.

    PubMed

    Ghaffari, Samad; Mehdizadeh-Lame, Mohammad-Bagher; Sepehrvand, Nariman; Aslanabadi, Naser; Sohrabi, Bahram; Separham, Ahmad; Jamshidi, Peiman

    2015-10-01

    The dimensions of the coronary arteries have been shown to vary among ethnic groups. There are no data available regarding the normal size of coronary arteries in Iranians. This study aimed to investigate normal coronary artery dimensions in a Northwestern Iranian population and to compare it with pooled data of Indo-Asians and Caucasians in previous studies. The study included 200 adults with suspected coronary disease who were referred for elective coronary angiography between June 2012 and March 2013 and were found to have normal epicardial flow in the coronary arteries. Quantitative coronary angiography was carried out on the longest atheroma-free part of the proximal segment of each coronary artery in all patients. Two Indo-Asian and Caucasian groups were selected and pooled for comparison with the available reports on individuals without coronary artery disease. The mean diameters of the left main coronary artery, proximal left anterior descending artery, proximal left circumflex, and proximal right coronary artery were 4.58 ± 0.80, 3.69 ± 0.64, 3.37 ± 0.73, and 3.47 ± 0.68 mm, respectively. The dimensions of the proximal part of the left main coronary artery and right coronary artery were significantly greater in the Northwestern Iranian population compared to the pooled Caucasian group. This difference was maintained even after correction for body surface area. Our data indicate larger coronary diameters in the Iranian population compared to Caucasians or South-Asians. Hence the high prevalence of coronary artery disease in Iran cannot be explained by coronary dimensions. © The Author(s) 2015.

  18. Value of two-dimensional echocardiography in the identification of pulmonary hypertension in chronic obstructive lung disease.

    PubMed

    Bertoli, L; Mantero, A; Alpago, R; Graziina, A; Tamponi, M; Pezzano, A

    1989-01-01

    Thirty-three patients suffering from chronic obstructive lung disease (COLD) were submitted to right heart two-dimensional echocardiographic (2D-ECHO) and hemodynamic study. By the subcostal approach, the right ventricle outflow tract including the pulmonary vessels was visualized in 85% of the patients. Most parameters measured on the right ventricle and pulmonary vessels were significantly higher than those recorded in the healthy control group. Very significant correlations were observed between the mean pulmonary artery pressure (PAP) and the following 2D-ECHO parameters: diameter of the pulmonary artery at valve level (r = 0.62; p less than 0.001); supravalvular diameter of the pulmonary artery (r = 0.44; p less than 0.03); diameter of the left branch of the pulmonary artery (r = 0.48; p less than 0.05); diameter of the right branch of the pulmonary artery (r = 0.39; p less than 0.05), and between the PAP and PaO2 (r = -0.66; p less than 0.001). Furthermore, the sensitivity, specificity, and accuracy of 2D-ECHO measurements were calculated to assess the presence of pulmonary hypertension. Overall sensitivity was 65%, specificity 75%, and accuracy 67%. However, by combining the value of PaO2 with that of the pulmonary valve by means of the multiple regression analysis, sensitivity increased to 84% in identifying pulmonary hypertension. Such data demonstrate that the 2D-ECHO study of the right heart in COLD patients has to carefully measure the dimensions of the pulmonary valve and the great pulmonary vessels, as their modification are mainly linked with the presence of pulmonary hypertension.(ABSTRACT TRUNCATED AT 250 WORDS)

  19. Effect of exogenous estradiol Benzoate on uterine blood flow in postpartum dairy cows.

    PubMed

    Rawy, Mohamed; Mido, Shogo; El-Sheikh Ali, Hossam; Derar, Derar; Megahed, Gaber; Kitahara, Go; Osawa, Takeshi

    2018-05-01

    The objective of this study was to assess the uterine blood flow following estradiol benzoate administration in Holstein-Friesian dairy cows by trans-rectal color Doppler ultrasonography. Six healthy lactating Holstein-Friesian cows were examined daily for 10 days starting at 4 weeks postpartum. All the cows, which were clinically healthy based on vaginal mucus scoring and endometrial cytology, were examined by trans-rectal Doppler ultrasonography to measure pulsatility index (PI), resistance index (RI), time average maximum velocity (TAMAX), blood flow volume (BFV) and diameter in the uterine arteries ipsilateral and contralateral to the previously pregnant uterine horn. On the third day of the experiment, the six cows were administered 10 mg intramuscular injection of estradiol-17β (E 2 ).Blood samples were collected at the time of daily examination for the assessment ofE 2 concentrations.The PI and RI values decreased while TAMAX, BFV and diameter of uterine arteries increased in response toE 2 administration (P < 0.05).There was a high correlation between both the ipsilateral and contralateral uterine arteries for all variables that were studied(r = 0.860, P < 0.0001, r = 0.922, P < 0.0001, r = 0.651, P < 0.0001, r = 0.879, P < 0.0001, r = 0.861, P < 0.0001 for the PI, RI, TAMAX, BFV and uterine arteries diameter, respectively).In conclusion, the greater blood concentrations ofE 2 may be responsible for the greater TAMAX, BFV, increased diameters and decreased PI and RI of the uterine arteries during the puerperium in dairy cows. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Effect of body repositioning after venous air embolism. An echocardiographic study

    NASA Technical Reports Server (NTRS)

    Geissler, H. J.; Allen, S. J.; Mehlhorn, U.; Davis, K. L.; Morris, W. P.; Butler, B. D.

    1997-01-01

    BACKGROUND: Current therapy for massive venous air embolism (VAE) may include the use of the left lateral recumbent (LLR) position, although its effectiveness has been questioned. This study used transesophageal echocardiography to evaluate the effect of body repositioning on intracardiac air and acute cardiac dimension changes. METHODS: Eighteen anesthetized dogs in the supine position received a venous air injection of 2.5 ml/kg at a rate of 5 ml/ s. After 1 min the dogs were repositioned into either the LLR, LLR 10 degrees head down (LLR-10 degrees), right lateral recumbence, or remained in the supine position. RESULTS: Repositioning after VAE resulted in relocation of intracardiac air to nondependent areas of the right heart. Peak right ventricular (RV) diameter increase and mean arterial pressure decrease were greater in the repositioned animals compared with those in the supine position (P < 0.05). Right ventricular diameter and mean arterial pressure showed an inverse correlation (r = 0.81). Peak left atrial diameter decrease was greater in the LLR and LLR-10 degrees positions compared with the supine position (P < 0.05). Repositioning did not influence peak pulmonary artery pressure increase, and no correlation was found between RV diameter and pulmonary artery pressure. All animals showed electrocardiogram and echocardiographic changes reconcilable with myocardial ischemia. CONCLUSIONS: In dogs, body repositioning after VAE provided no benefit in hemodynamic performance or cardiac dimension changes, although relocation of intracardiac air was demonstrated. Right ventricular air did not appear to result in significant RV outflow obstruction, as pulmonary artery pressure increased uniformly in all groups and was not influenced by the relocation of intracardiac air. The combination of increased RV afterload and arterial hypotension, possibly with subsequent RV ischemia rather than RV outflow obstruction by an airlock appeared to be the primary mechanism for cardiac dysfunction after VAE.

  1. Albuminuria, but not estimated glomerular filtration rate, is associated with maladaptive arterial remodeling: the Hoorn Study.

    PubMed

    Hermans, Marc M H; Henry, Ronald M A; Dekker, Jaqueline M; Nijpels, Giel; Heine, Rob J; Stehouwer, Coen D A

    2008-04-01

    Arterial remodeling aims to maintain a constant circumferential wall stress (sigmac). A failing remodeling process is associated with stroke. Data on the relationship between chronic kidney disease and arterial remodeling are scarce. We investigated the association between a lower glomerular filtration rate (GFR) and microalbuminuria with arterial remodeling of the common carotid artery (CCA) in a population-based study of 806 patients. CCA properties including intima-media thickness and interadventitial diameter (IAD) were assessed. Lumen diameter, circumferential wall tension (CWT), and circumferential wall stress (sigmac) were calculated. GFR was estimated (eGFR) by the Modification of Diet in Renal Disease formula. Albuminuria was expressed as urinary albumin/creatinine ratio. Mean eGFR was 60.3 (+/-10.8) ml/min/1.73 m2; median urinary albumin/creatinine ratio was 0.57 (range 0.10-26.6 mg/mmol). After adjustment for age, sex, glucose tolerance status, and prevalent cardiovascular disease, eGFR was not independently associated with CCA properties. A greater urinary albumin/creatinine ratio (per quartile) was associated with a greater lumen diameter [regression coefficient beta with 95% confidence interval, 0.14 (0.08-0.20; P < 0.01)], IAD [0.15 (0.09-0.21; P < 0.01)], CWT [0.95 (0.52-1.38; P < 0.01)], and sigmac [1.7 (0.5-2.9; P < 0.01)] but not with a greater IMT [0.01 (-0.002-0.02; P = 0.12)]. Additional adjustments for mean arterial pressure, pulse pressure, and eGFR did not change the results. Greater albuminuria is independently associated with an increase in lumen diameter and IAD of the CCA. In addition, greater albuminuria is associated with a maladaptive carotid remodeling process as shown by an increase in CWT and sigmac. These findings may explain, why microalbuminuria is associated with a greater risk of cardiovascular disease and especially stroke.

  2. Local and systemic effects of leg cycling training on arterial wall thickness in healthy humans.

    PubMed

    Thijssen, Dick H J; Dawson, Ellen A; van den Munckhof, Inge C L; Birk, Gurpreet K; Timothy Cable, N; Green, Daniel J

    2013-08-01

    Exercise training is associated with direct effects on conduit artery function and structure. Cross-sectional studies suggest the presence of systemic changes in wall thickness as a result of exercise in healthy subjects, but no previous study has examined this question in humans undertaking exercise training. To examine the change in superficial femoral (SFA, i.e. local effect) and carotid (CA, i.e. systemic effect) artery wall thickness across 8 weeks of lower limb cycle training in healthy young men. Fourteen healthy young male subjects were assigned to an 8-week training study of cycling exercise (n = 9) or a control period (n = 5). Before, during (2, 4 and 6 weeks) and after training, SFA and CA wall thickness was examined using automated edge-detection of high resolution ultrasound images. We also measured resting diameter and calculated the wall:lumen(W:L)-ratio. Exercise training did not alter CA or SFA baseline diameter (P = 0.14), but was associated with gradual, consistent and significant decreases in wall thickness and W:L-ratio in both the CA and SFA (P < 0.001 and 0.002, respectively). Two-way ANOVA revealed a comparable magnitude of decrease in wall thickness and W:L-ratio in both arteries across the 8-week period (interaction-effect; P = 0.29 and 0.12, respectively). No changes in artery diameter, wall thickness or W:L-ratio were apparent in controls (0.82, 0.38 and 0.52, respectively). We found that cycle exercise training in healthy young individuals is associated with modest, but significant, decreases in wall thickness in the superficial femoral and carotid arteries. These findings suggest that exercise training causes systemic adaptation of the arterial wall in healthy young subjects. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  3. Explorations of roundwood technology in buildings

    Treesearch

    Jeffrey Cook

    2001-01-01

    A report and critical commentary is presented on the use of small diameter roundwood in building construction in the United States and England. Examples are discussed of roundwood joinery being evaluated at the USDA Forest Service's Forest Products Laboratory, and joinery developed by the British engineering consulting firm Buro Happold, working over 15 years in...

  4. MICROBIAL SOLUTION: APPLICATION OF MICROORGANISMS FOR BIOFUEL PRODUCTION AND CO2 MITIGATION

    EPA Science Inventory

    A 100 L photobioreactor for biodiesel generation from microalga Chlorella vulgaris was constructed from two parallel clear PVC 10 feet tubes (6’ diameter) with a small slope (10%). The gas mixture (5% CO2 and air) flowed up the top of the PVC tubes from the bottom as...

  5. Automated assessment of aortic and main pulmonary arterial diameters using model-based blood vessel segmentation for predicting chronic thromboembolic pulmonary hypertension in low-dose CT lung screening

    NASA Astrophysics Data System (ADS)

    Suzuki, Hidenobu; Kawata, Yoshiki; Niki, Noboru; Sugiura, Toshihiko; Tanabe, Nobuhiro; Kusumoto, Masahiko; Eguchi, Kenji; Kaneko, Masahiro

    2018-02-01

    Chronic thromboembolic pulmonary hypertension (CTEPH) is characterized by obstruction of the pulmonary vasculature by residual organized thrombi. A morphological abnormality inside mediastinum of CTEPH patient is enlargement of pulmonary artery. This paper presents an automated assessment of aortic and main pulmonary arterial diameters for predicting CTEPH in low-dose CT lung screening. The distinctive feature of our method is to segment aorta and main pulmonary artery using both of prior probability and vascular direction which were estimated from mediastinal vascular region using principal curvatures of four-dimensional hyper surface. The method was applied to two datasets, 64 lowdose CT scans of lung cancer screening and 19 normal-dose CT scans of CTEPH patients through the training phase with 121 low-dose CT scans. This paper demonstrates effectiveness of our method for predicting CTEPH in low-dose CT screening.

  6. [Development of a continuous blood pressure monitoring and recording system].

    PubMed

    Zhang, Yang; Li, Yong; Gao, Shumei; Song, Yilin

    2012-09-01

    A small experimental system is constructed with working principle of continuous blood pressure monitoring based on the volume compensation method. The preliminary experimental results show that the system can collect blood pressure signals at the radial artery effectively. The digital PID algorithm can track the variation of blood pressure. And the accuracy of continuous blood pressure detecting achieve the level of same kind of product.

  7. Stent sizing strategies in renal artery stenting: the comparison of conventional invasive renal angiography with renal computed tomographic angiography.

    PubMed

    Kadziela, Jacek; Michalowska, Ilona; Pregowski, Jerzy; Janaszek-Sitkowska, Hanna; Lech, Katarzyna; Kabat, Marek; Staruch, Adam; Januszewicz, Andrzej; Witkowski, Adam

    2016-01-01

    Randomized trials comparing invasive treatment of renal artery stenosis with standard pharmacotherapy did not show substantial benefit from revascularization. One of the potential reasons for that may be suboptimal procedure technique. To compare renal stent sizing using two modalities: three-dimensional renal computed tomography angiography (CTA) versus conventional angiography. Forty patients (41 renal arteries), aged 65.1 ±8.5 years, who underwent renal artery stenting with preprocedural CTA performed within 6 months, were retrospectively analyzed. In CTA analysis, reference diameter (CTA-D) and lesion length (CTA_LL) were measured and proposed stent diameter and length were recorded. Similarly, angiographic reference diameter (ANGIO_D) and lesion length (ANGIO_LL) as well as proposed stent dimensions were obtained by visual estimation. The median CTA_D was 0.5 mm larger than the median ANGIO_D (p < 0.001). Also, the proposed stent diameter in CTA evaluation was 0.5 mm larger than that in angiography (p < 0.0001). The median CTA_LL was 1 mm longer than the ANGIO_LL (p = NS), with significant correlation of these variables (r = 0.66, p < 0.0001). The median proposed stent length with CTA was equal to that proposed with angiography. The median diameter of the implanted stent was 0.5 mm smaller than that proposed in CTA (p < 0.0005) and identical to that proposed in angiography. The median length of the actual stent was longer than that proposed in angiography (p = 0.0001). Renal CTA has potential advantages as a tool adjunctive to angiography in appropriate stent sizing. Careful evaluation of the available CTA scans may be beneficial and should be considered prior to the planned procedure.

  8. Stent sizing strategies in renal artery stenting: the comparison of conventional invasive renal angiography with renal computed tomographic angiography

    PubMed Central

    Michalowska, Ilona; Pregowski, Jerzy; Janaszek-Sitkowska, Hanna; Lech, Katarzyna; Kabat, Marek; Staruch, Adam; Januszewicz, Andrzej; Witkowski, Adam

    2016-01-01

    Introduction Randomized trials comparing invasive treatment of renal artery stenosis with standard pharmacotherapy did not show substantial benefit from revascularization. One of the potential reasons for that may be suboptimal procedure technique. Aim To compare renal stent sizing using two modalities: three-dimensional renal computed tomography angiography (CTA) versus conventional angiography. Material and methods Forty patients (41 renal arteries), aged 65.1 ±8.5 years, who underwent renal artery stenting with preprocedural CTA performed within 6 months, were retrospectively analyzed. In CTA analysis, reference diameter (CTA-D) and lesion length (CTA_LL) were measured and proposed stent diameter and length were recorded. Similarly, angiographic reference diameter (ANGIO_D) and lesion length (ANGIO_LL) as well as proposed stent dimensions were obtained by visual estimation. Results The median CTA_D was 0.5 mm larger than the median ANGIO_D (p < 0.001). Also, the proposed stent diameter in CTA evaluation was 0.5 mm larger than that in angiography (p < 0.0001). The median CTA_LL was 1 mm longer than the ANGIO_LL (p = NS), with significant correlation of these variables (r = 0.66, p < 0.0001). The median proposed stent length with CTA was equal to that proposed with angiography. The median diameter of the implanted stent was 0.5 mm smaller than that proposed in CTA (p < 0.0005) and identical to that proposed in angiography. The median length of the actual stent was longer than that proposed in angiography (p = 0.0001). Conclusions Renal CTA has potential advantages as a tool adjunctive to angiography in appropriate stent sizing. Careful evaluation of the available CTA scans may be beneficial and should be considered prior to the planned procedure. PMID:27279870

  9. Automated airway evaluation system for multi-slice computed tomography using airway lumen diameter, airway wall thickness and broncho-arterial ratio

    NASA Astrophysics Data System (ADS)

    Odry, Benjamin L.; Kiraly, Atilla P.; Novak, Carol L.; Naidich, David P.; Lerallut, Jean-Francois

    2006-03-01

    Pulmonary diseases such as bronchiectasis, asthma, and emphysema are characterized by abnormalities in airway dimensions. Multi-slice computed tomography (MSCT) has become one of the primary means to depict these abnormalities, as the availability of high-resolution near-isotropic data makes it possible to evaluate airways at oblique angles to the scanner plane. However, currently, clinical evaluation of airways is typically limited to subjective visual inspection only: systematic evaluation of the airways to take advantage of high-resolution data has not proved practical without automation. We present an automated method to quantitatively evaluate airway lumen diameter, wall thickness and broncho-arterial ratios. In addition, our method provides 3D visualization of these values, graphically illustrating the location and extent of disease. Our algorithm begins by automatic airway segmentation to extract paths to the distal airways, and to create a map of airway diameters. Normally, airway diameters decrease as paths progress distally; failure to taper indicates abnormal dilatation. Our approach monitors airway lumen diameters along each airway path in order to detect abnormal profiles, allowing even subtle degrees of pathologic dilatation to be identified. Our method also systematically computes the broncho-arterial ratio at every terminal branch of the tree model, as a ratio above 1 indicates potentially abnormal bronchial dilatation. Finally, the airway wall thickness is computed at corresponding locations. These measurements are used to highlight abnormal branches for closer inspection, and can be summed to compute a quantitative global score for the entire airway tree, allowing reproducible longitudinal assessment of disease severity. Preliminary tests on patients diagnosed with bronchiectasis demonstrated rapid identification of lack of tapering, which also was confirmed by corresponding demonstration of elevated broncho-arterial ratios.

  10. Morphological variations of intra-testicular arterial vasculature in bovine testis--a corrosion casting study.

    PubMed

    Polguj, Michał; Wysiadecki, Grzegorz; Podgórski, Michał; Szymański, Jacek; Olbrych, Katarzyna; Olewnik, Łukasz; Topol, Mirosław

    2015-10-15

    Proper blood supply is necessary for the physiological function of every internal organ. The article offers the first classification of the bovine intra-testicular arteries. A corrosive study focused on the intra-testicular arterial vasculature was performed on 40 bovine testes. The vessels were analyzed accurately using MultiScanBase v.18.02 software. A corrosive study focused on the intra-testicular arteries was performed on 40 bovine testes. The vessels were analyzed accurately using MultiScanBase v.18.02 software. In bulls, the centripetal arteries tended to run straight to the mediastinal region, where they form knot-like vascular structures. Those structures are the origin for centrifugal recurrent branches, running peripherally. However, three basic types of intra-testicular arterial vasculature were noted. Type I had centrifugal, recurrent branches, running peripherally towards the surface of the testis but did not reach the tunica albuginea. Type II exhibited centrifugal, recurrent branches running more horizontally than type I. Type III is the most heterogeneous type, composed of other variform types of arteries not classified as type I or type II. Type II was most commonly observed as a vascular conglomerate of intra-testicular arteries within the arterial network of the mediastinum testis. In type III, artery diameter was significantly smaller than observed in types I and II (p < 0.01). Types I and II did not differ between each other regarding artery diameter (p > 0.05). Variations of the intra-testicular arterial vasculature in bovine testis may suggest that particular types of vessels play different physiological roles. The most common type of intra-testicular artery comprising the arterial network of the mediastinum testis was type II.

  11. Anatomical Consideration and Potential Complications of Coronary Sinus Catheterisation.

    PubMed

    Mehra, Lalit; Raheja, Shashi; Agarwal, Sneh; Rani, Yashoda; Kaur, Kulwinder; Tuli, Anita

    2016-02-01

    Coronary venous catheterisation has been used for performing various cardiologic interventions. The procedure might become complicated due to obstruction offered by the valve of coronary sinus (Thebesian valve) the acute bend of the Great Cardiac Vein (GCV). The present study sought to expound the anatomical considerations of coronary venous catheterization and to elucidate the potential causes of obstruction and the complications of this procedure. In this cross-sectional observational study, coronary sinus and GCV were dissected in 40, formalin fixed, adult cadaveric human hearts. Course, length, diameter and angle of bend of GCV, length of coronary sinus and its diameter at its ostium in right atrium were recorded. Thebesian valve morphology and percentage coverage of coronary sinus ostium was recorded. Relation of the coronary sinus and GCV with their neighbouring arteries was described. Coronary sinus: near its termination was directly related to the left atrium. Length: 35.35±4.43 mm (1 SD). Diameter: 11.75 ± 2.66mm. Diameter of CS ostium was more in hearts where Thebesian valve was absent. GCV travelled superficial or deep to the left diagonal artery and crossed circumflex artery superficially. Length: 96.23 ±22.52mm. Diameter: 5.99 ±1.02mm. Angle of bend: 107 ±6.74 degrees. Thebesian valve: Absent in 3 hearts. Various morphologies were observed: thin band, thin band with fenestrations, broad band with fenestrations, well developed semilunar valve (Thin/thick). In five hearts, valve covered more than 50% of coronary sinus ostium. Coronary sinus and GCV diameter will help cardiologists and cardiothoracic surgeons to choose an appropriate sized catheter and their length will decide the length of catheter advancement. Thebesian valve may cause obstruction to the catheter due to an extensive coverage of coronary sinus ostium, which is seen in 12.5% cases. The obtuse angle of GCV has to be negotiated in order to enter this vessel. Arteries lying deep to coronary sinus and GCV might be compressed leading to myocardial ischemia.

  12. Brachial artery stiffness estimation using ARTSENS.

    PubMed

    Kiran, V Raj; Nabeel, P M; Joseph, Jayaraj; Sivaprakasam, Mohanasankar

    2017-07-01

    Central and peripheral arteries stiffening prominently affect hemodynamics thus increasing the risk of coronary heart disease, chronic kidney disease and end stage renal disease. There are several commercially available non-invasive measurement technologies for the evaluation of stiffness that are expensive, demand dedicated expertise and fall short for mass screening. Considering this, we have developed ARTSENS ® , a highly compact and portable image-free ultrasound device for evaluation of arterial stiffness. The capability of the device to perform accurate measurements of carotid artery stiffness has been validated through extensive in-vivo studies. In this paper we demonstrate the feasibility of using ARTSENS ® for measuring brachial artery stiffness. An inter-operator repeatability study was done based on in-vivo experiments on 9 young healthy subjects. The study included measurement of distension, end diastolic lumen diameter, arterial compliance and stiffness index performed both on carotid artery and brachial artery by two operators successively. The degree of agreement between the measurements made by operators has been investigated based on Bland-Altman plots and paired t-test. The measurements were populated within the limits of agreement. No statistically significant difference (p-values from paired t-test for end-diastolic diameter, distension, stiffness index, arterial compliance were 0.36, 0.24, 0.47 and 0.11 respectively) was seen for the brachial artery measurements performed by the two operators. The correlation between the measurement made by the operators was highly significant (r=0.86, p-value=0.003).

  13. Analysis of Iliac Artery Geometric Properties in Fenestrated Aortic Stent Graft Rotation.

    PubMed

    Doyle, Matthew G; Crawford, Sean A; Osman, Elrasheed; Eisenberg, Naomi; Tse, Leonard W; Amon, Cristina H; Forbes, Thomas L

    2018-04-01

    A complication of fenestrated endovascular aneurysm repair is the potential for stent graft rotation during deployment causing fenestration misalignment and branch artery occlusion. The objective of this study is to demonstrate that this rotation is caused by a buildup of rotational energy as the device is delivered through the iliac arteries and to quantify iliac artery geometric properties associated with device rotation. A retrospective clinical study was undertaken in which iliac artery geometric properties were assessed from preoperative imaging for 42 cases divided into 2 groups: 27 in the nonrotation group and 15 in the rotation group. Preoperative computed tomography scans were segmented, and the iliac artery centerlines were determined. Iliac artery tortuosity, curvature, torsion, and diameter were calculated from the centerline and the segmented vessel geometry. The total iliac artery net torsion was found to be higher in the rotation group compared to the nonrotation group (23.5 ± 14.7 vs 14.6 ± 12.8 mm -1 ; P = .05). No statistically significant differences were found for the mean values of tortuosity, curvature, torsion, or diameter between the 2 groups. Stent graft rotation occurred in 36% of the cases considered in this study. Cases with high iliac artery total net torsion were found to be more likely to have stent graft rotation upon deployment. This retrospective study provides a framework for prospectively studying the influence of iliac artery geometric properties on fenestrated stent graft rotation.

  14. Children and Adolescent Obesity Associates with Pressure-Dependent and Age-Related Increase in Carotid and Femoral Arteries' Stiffness and Not in Brachial Artery, Indicative of Nonintrinsic Arterial Wall Alteration

    PubMed Central

    García-Espinosa, Victoria; Curcio, Santiago; Castro, Juan Manuel; Arana, Maite; Giachetto, Gustavo; Chiesa, Pedro; Zócalo, Yanina

    2016-01-01

    Aim. To analyze if childhood obesity associates with changes in elastic, transitional, and/or muscular arteries' stiffness. Methods. 221 subjects (4–15 years, 92 females) were assigned to normal weight (NW, n = 137) or obesity (OB, n = 84) groups, considering their body mass index z-score. Age groups were defined: 4–8; 8–12; 12–15 years old. Carotid, femoral, and brachial artery local stiffness was determined through systodiastolic pressure-diameter and stress-strain relationships. To this end, arterial diameter and peripheral and aortic blood pressure (BP) levels and waveforms were recorded. Carotid-femoral, femoropedal, and carotid-radial pulse wave velocities were determined to evaluate aortic, lower-limb, and upper-limb regional arterial stiffness, respectively. Correlation analysis between stiffness parameters and BP was done. Results. Compared to NW, OB subjects showed higher peripheral and central BP and carotid and femoral stiffness, reaching statistical significance in subjects aged 12 and older. Arterial stiffness differences disappeared when levels were normalized for BP. There were no differences in intrinsic arterial wall stiffness (elastic modulus), BP stiffness relationships, and regional stiffness parameters. Conclusion. OB associates with BP-dependent and age-related increase in carotid and femoral (but not brachial) stiffness. Stiffness changes would not be explained by intrinsic arterial wall alterations but could be associated with the higher BP levels observed in obese children. PMID:27066273

  15. Failure mode and bending moment of canine pancarpal arthrodesis constructs stabilized with two different implant systems.

    PubMed

    Wininger, Fred A; Kapatkin, Amy S; Radin, Alex; Shofer, Frances S; Smith, Gail K

    2007-12-01

    To compare failure mode and bending moment of a canine pancarpal arthrodesis construct using either a 2.7 mm/3.5 mm hybrid dynamic compression plate (HDCP) or a 3.5 mm dynamic compression plate (DCP). Paired in vitro biomechanical testing of canine pancarpal arthrodesis constructs stabilized with either a 2.7/3.5 HDCP or 3.5 DCP. Paired cadaveric canine antebrachii (n=5). Pancarpal arthrodesis constructs were loaded to failure (point of maximum load) in 4-point bending using a materials-testing machine. Using this point of failure, bending moments were calculated from system variables for each construct and the 2 plating systems compared using a paired t-test. To examine the relationship between metacarpal diameter and screw diameter failure loads, linear regression was used and Pearson' correlation coefficient was calculated. Significance was set at P<.05. HDCP failed at higher loads than DCP for 9 of 10 constructs. The absolute difference in failure rates between the 2 plates was 0.552+/-0.182 N m, P=.0144 (95% confidence interval: -0.58 to 1.68). This is an 8.1% mean difference in bending strength. There was a significant linear correlation r=0.74 (P-slope=.014) and 0.8 (P-slope=.006) between metacarpal diameter and failure loads for the HDCP and 3.5 DCP, respectively. There was a small but significant difference between bending moment at failure between 2.7/3.5 HDCP and 3.5 DCP constructs; however, the difference may not be clinically evident in all patients. The 2.7/3.5 HDCP has physical and mechanical properties making it a more desirable plate for pancarpal arthrodesis.

  16. Arterio-venous anastomoses in the human skin and their role in temperature control

    PubMed Central

    Walløe, Lars

    2016-01-01

    ABSTRACT Arterio-venous anastomoses (AVAs) are direct connections between small arteries and small veins. In humans they are numerous in the glabrous skin of the hands and feet. The AVAs are short vessel segments with a large inner diameter and a very thick muscular wall. They are densely innervated by adrenergic axons. When they are open, they provide a low-resistance connection between arteries and veins, shunting blood directly into the venous plexuses of the limbs. The AVAs play an important role in temperature regulation in humans in their thermoneutral zone, which for a naked resting human is about 26°C to 36°C, but lower when active and clothed. From the temperature control center in the hypothalamus, bursts of nerve impulses are sent simultaneously to all AVAs. The AVAs are all closed near the lower end and all open near the upper end of the thermoneutral zone. The small veins in the skin of the arms and legs are also contracted near the lower end of the thermoneutral zone and relax to a wider cross section as the ambient temperature rises. At the cold end of the thermoneutral range, the blood returns to the heart through the deep veins and cools the arterial blood through a countercurrent mechanism. As the ambient temperature rises, more blood is returned through the superficial venous plexuses and veins and heats the skin surface of the full length of the 4 limbs. This skin surface is responsible for a large part of the loss of heat from the body toward the upper end of the thermoneutral zone. PMID:27227081

  17. Extraglandular and intraglandular vascularization of canine prostate.

    PubMed

    Stefanov, Miroslav

    2004-03-01

    The literature on the vascularization of the canine prostate is reviewed and the clinical significance of prostate morphology is described. Scanning Electron Microscopy (SEM), combined with improved corrosion casting methods, reveal new morphological details that promise better diagnostics and treatment but also require expansion of clinical nomenclature. A proposal is made for including two previously unnamed veins in Nomina Anatomica Veterinaria (NAV). The canine prostate has two lobes with independent vascularization. Each lobe is supplied through the left and right a. prostatica, respectively. The a. prostatica sprouts three small vessels (cranial, middle, and caudal) towards the prostate gland. A. prostatica is a small-size artery whose wall structure is similar to the arteries of the muscular type. V. prostatica is a small-size valved vein. The canine prostate has capsular, parenchymal, and urethral vascular zones. The surface vessels of the capsule are predominantly veins and the diameter of arterial vessels is larger than that of the veins. The trabecular vessels are of two types: direct and branched. The prostate parenchyma is supplied by branches of the trabecular vessels. The periacinary capillaries are fenestrated and form a net in a circular pattern. The processes of the myoepithelial cells embrace both the acins and the periacinar capillaries. In the prostate ductal system. there are spermatozoa. The prostatic part of the urethra is supplied by an independent branch of a. prostatica. The prostatic urethral part is drained by v. prostatica, the vein of the urethral bulb and the ventral prostate veins. M. urethralis begins as early as the urethral prostatic part. The greater part of the white muscle fibers in m. urethralis suggest an enhanced anaerobic metabolism. Copyright 2004 Wiley-Liss, Inc.

  18. Iatrogenic injuries of the common femoral artery (CFA) and external iliac artery (EIA) during endograft placement: an underdiagnosed entity.

    PubMed

    Hingorani, Anil P; Ascher, Enrico; Marks, Natalie; Shiferson, Alexander; Patel, Nirav; Gopal, Kapil; Jacob, Theresa

    2009-09-01

    Early limb occlusions following endovascular treatment of aorto-iliac aneurysmal disease is not uncommon (4%-13%). To assess whether the femoral artery entry site could potentially cause this complication, we prospectively evaluated the ipsilateral common femoral artery (CFA) and distal external iliac artery (EIA) with intraoperative duplex scans (IDS). There were 134 patients with infrarenal nonruptured abdominal aorto-iliac aneurysms treated with endografts since 2002 at our institution. Age ranged from 65 to 89 years (mean: 77 +/- 7 years). Aneuryx (n = 41), Zenith (n = 50), and Excluder (n = 43) endografts were used for repair. All procedures were performed via open exposure of the CFA. Introducer diameter varied from 12 mm to 22 mm. All patients underwent IDS of the CFA and distal EIA after repair of the arteriotomies. In 34 patients (25%), we documented intimal dissections causing severe (>70%) stenoses. Of the 271 arteries that were examined, 38 (14%) had abnormal findings that demanded intervention. These were repaired with flap excision, tacking sutures revision, or patch angioplasty (n = 36). Repeat IDS confirmed the adequacy of the repair. No statistical difference was noted if the site of larger introducer sheath and the incidence of flap formation. In addition, 10 small flaps or plaques were visualized but did not create significant stenosis. No differences were noted in the incidence of positive duplex exams between each type graft (P = .4). No early or late iliac limb occlusions were noted. Follow-up of 94% was obtained. Completion arterial duplex scans are helpful in detecting a substantial number of clinically unsuspected technical defects caused by introducer sheaths. Timely diagnosis and repair of these defects may decrease the incidence of early limb occlusion following endograft placement.

  19. Subcortical hematoma caused by cerebral amyloid angiopathy: does the first evidence of hemorrhage occur in the subarachnoid space?

    PubMed

    Takeda, Shigeki; Yamazaki, Kazunori; Miyakawa, Teruo; Onda, Kiyoshi; Hinokuma, Kaoru; Ikuta, Fusahiro; Arai, Hiroyuki

    2003-12-01

    Six autopsy cases of subcortical hematoma caused by CAA were examined to elucidate the primary site of hemorrhage. Immunohistochemistry for amyloid beta-protein (A beta) revealed extensive CAA in the intrasulcal meningeal vessels rather than in the cerebral cortical vessels. All of the examined cases had multiple hematomas in the subarachnoid space, mainly in the cerebral sulci, as well as intracerebral hematomas. Each intracerebral hematoma was connected to the subarachnoid hematomas at the depth of cerebral sulci or through the lateral side of the cortex. There was no debris of the cerebral cortical tissue in the subarachnoid hematomas. In case 2, another solitary subarachnoid hematoma, which was not connected to any intracerebral hematoma, was seen. In all of these subarachnoid hematomas, many ruptured A beta-immunopositive arteries were observed. These ruptured arteries did not accompany any debris of the brain tissue, some of them were large in diameter (250-300 microm), and several of them were far from the cerebral cortex. Therefore, it was considered that they were not cortical arteries but meningeal arteries. Within the cerebral cortex, there were only a few ruptured arteries associated with small hemorrhages. There were no ruptured vessels within the intracerebral hematomas. There was a strong suggestion that all of the subarachnoid hematomas, including the solitary one in case 2, originated from the rupture of the meningeal arteries. The present study indicates that in some cases of subcortical hematoma caused by CAA, the primary hemorrhage occurs in the subarachnoid space, in particular the cerebral sulci, because of rupture of multiple meningeal arteries. Infarction occurs subsequently in the cortex around the hematoma, the hematoma penetrates into the brain parenchyma, and finally, a subcortical hematoma is formed.

  20. Multidetector computed tomography for preoperative evaluation of vascular anatomy in living renal donors.

    PubMed

    Türkvatan, Aysel; Akinci, Serkan; Yildiz, Sener; Olçer, Tülay; Cumhur, Turhan

    2009-04-01

    Currently, multidetector computed tomographic (MDCT) angiography has become a noninvasive alternative imaging modality to catheter renal angiography for the evaluation of renal vascular anatomy in living renal donors. In this study, we investigated the diagnostic accuracy of 16-slice MDCT in the preoperative assessment of living renal donors. Fifty-nine consecutive living renal donors (32 men, 27 women) underwent MDCT angiography followed by open donor nephrectomy. All MDCT studies were performed by using a 16-slice MDCT scanner with the same protocol consisting of arterial and nephrographic phases followed by conventional abdominal radiography. The MDCT images were assessed retrospectively for the number and branching pattern of the renal arteries and for the number and presence of major or minor variants of the renal veins. The results were compared with open surgical results. The sensitivity and specificity of MDCT for the detection of anatomic variants of renal arteries including the accessory arteries (n = 9), early arterial branching (n = 7) and major renal venous anomalies including the accessory renal veins (n = 3), late venous confluence (n = 4), circumaortic (n = 2) or retroaortic (n = 3) left renal veins were 100%. However, the sensitivity for identification of minor venous variants was 79%. All of three ureteral duplications were correctly identified at excretory phase conventional abdominal radiography. Sixteen-slice MDCT is highly accurate for the identification of anatomic variants of renal arteries and veins. Dual-phase MDCT angiography including arterial and nephrographic phases followed by conventional abdominal radiography enables complete assessment of renal donors without significant increase of radiation dose. However, the evaluation of minor venous variants may be problematic because of their small diameters and poor opacification.

  1. Morphological Differences in the Aorto-iliac Segment in AAA Patients of Caucasian and Asian Origin.

    PubMed

    Banzic, I; Lu, Q; Zhang, L; Stepak, H; Davidovic, L; Oszkinis, G; Mladenovic, A; Markovic, M; Rancic, Z; Jing, Z; Brankovic, M

    2016-06-01

    The objective was to quantify aorto-iliac morphology differences between AAA patients of Caucasian and Asian origin. Additionally, the impact of patient demographic characteristics was assessed, which could influence the morphological differences. This international multicentre study included two tertiary referral institutions from Europe and one from China. CT scans with 3D reconstruction of 296 patients with infrarenal AAA >5 cm were analysed. Eighteen measurements were recorded from each CT scan and compared between Caucasian and Asian patients. Caucasian patients had longer common iliac arteries (right: 65.0 vs. 33.1 mm, p < .001 left: 65.0 vs. 35.2 mm, p < .001), longer aneurysm neck (33.0 vs. 28.4 mm, p < .001), greater aneurysm to aortic axis angle (153.0° vs. 142.2°, p < .001), and longer combined aorto-iliac length (195.7 vs. 189.2 mm, p < .001). However, Asian patients had a longer infrarenal abdominal aorta (152.0 vs. 130.0 mm, p < .001), longer AAA (126.2 vs. 93.0 mm), and greater linear distance from renal artery to aorto-iliac bifurcation (143.6 vs. 116.0 mm, p < .001). Caucasian patients had a larger inner common iliac artery diameter (right: 16.0 vs. 14.9 mm, p < .001, left: 16.0 vs. 15.2 mm, p < .001), larger inner exernal iliac artery diameter (right: 9.0 vs. 7.5 mm, p < .001 left: 9.0 vs. 7.7 mm, p < .001), and larger inner common femoral artery diameter (right: 10.0 vs. 5.9 mm, p < .001 left: 10.0 vs. 6.1 mm, p < .001). No difference was observed in AAA transverse diameter (62.0 vs. 63.1 mm, p = .492). The results showed that aorto-iliac anatomy in Caucasians differs significantly from Asians, particularly in the length of the common iliac arteries and infrarenal abdominal aorta, and in the transverse diameter of the common, external iliac, and common femoral arteries. Therefore, the exact criteria for stent graft design are dependent on the racial origin of the patient. Copyright © 2015 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  2. Evaluation of uterine artery recanalization and doppler parameters after bilateral uterine artery ligation in women with postpartum hemorrhage

    PubMed Central

    Kaplanoglu, Mustafa; Karateke, Atilla; Un, Burak; Gunsoy, Levend; Baloglu, Ali

    2015-01-01

    Aim: The evaluation of the uterine artery recanalization rate and color Doppler parameters during follow-up after bilateral uterine artery ligation (BUAL) for postpartum hemorrhage (PPH) related to uterine atony. Material and method: A total of 40 female patients who underwent BUAL for PPH related to uterine atony and 96 females who gave birth without complication at Hatay Obstetrics and Gynecology Hospital between January 2009 and December 2012 (48 months) were included in the study. The patients’ uterine artery recanalization rate and all subjects’ color Doppler ultrasonographic parameters (PI, RI, PSV and EDV) were evaluated at the 6th and 12th months. Result: No statistically significant difference was found between the age, obstetric history (gravida and parity), BMI, type of delivery, birth weight and gestational age when the demographic data of the groups were evaluated. The patient group UtA recanalization rate was 32.5% and 37.5% for the left and right UtA respectively at the 12-month follow-up. No statistically significant difference was found in the comparison of 6- and 12-month right and left uterine artery diameters and color doppler parameters of the patient group (UtA diameters P=0.322 and P=0.787, RI index P=0.390 and P=0.094, PI index P=0.949 and P=0.374, PSV P=0.335 and P=0.085, EDV P=0.173 and P=0.418, respectively). However, right and left ovarian volume was found to significantly increase during follow-up in patient group (P<0.001 for both right and left ovary). On the other hand, a statistically significant difference was found between the patient group and the control group in the comparison of the 6- and 12-month right and left uterine artery values (6th month; P<0.001 for both UtA diameters, RI, PI, PSV, EDV; 12th month; P<0.001 for right UtA diameter, RI, PI, PSV, EDV and P=0.002 for left UtA diameter). A statistically significant difference was found only in right ovary volume in the 6th month evaluation of the patient and control group ovary volumes (P=0.011). Discussion: The recanalization rate and isolated uterine blood supply during low-term follow-up are low following the BUAL technique. The evaluation of future fertility results will be helpful in determining the reliability of this procedure in a definite manner. PMID:26221335

  3. CFD-based Thrombotic Risk Assessment in Kawasaki Disease Patients with Coronary Artery Aneurysms

    NASA Astrophysics Data System (ADS)

    Sengupta, Dibyendu; Kung, Ethan; Kahn, Andrew; Burns, Jane; Marsden, Alison

    2012-11-01

    Coronary aneurysms occur in 25% of untreated Kawasaki Disease (KD) patients and put patients at increased risk for myocardial infarction and sudden death. Clinical guidelines recommend using aneurysm diameter >8 mm as the arbitrary criterion for treating with anti-coagulation therapy. This study uses patient-specific modeling to non-invasively determine hemodynamic parameters and quantify thrombotic risk. Anatomic models were constructed from CT angiographic image data from 5 KD aneurysm patients and one normal control. CFD simulations were performed to obtain hemodynamic data including WSS and particle residence times (PRT). Thrombosis was clinically observed in 4/9 aneurysmal coronaries. Thrombosed vessels required twice as many cardiac cycles (mean 8.2 vs. 4.2) for particles to exit, and had lower mean WSS (1.3 compared to 2.8 dynes/cm2) compared to vessels with non-thrombosed aneurysms of similar max diameter. 1 KD patient in the cohort with acute thrombosis had diameter < 8 mm. Regions of low WSS and high PRT predicted by simulations correlated with regions of subsequent thrombus formation. Thrombotic risk stratification for KD aneurysms may be improved by incorporating both hemodynamic and geometric quantities. Current clinical guidelines to assess patient risk based only on aneurysm diameter may be misleading. Further prospective study is warranted to evaluate the utility of patient-specific modeling in risk stratifying KD patients with coronary aneurysms. NIH R21.

  4. Trace of totally positive algebraic integers and integer transfinite diameter

    NASA Astrophysics Data System (ADS)

    Flammang, V.

    2009-06-01

    Explicit auxiliary functions can be used in the ``Schur-Siegel- Smyth trace problem''. In the previous works, these functions were constructed only with polynomials having all their roots positive. Here, we use several polynomials with complex roots, which are found with Wu's algorithm, and we improve the known lower bounds for the absolute trace of totally positive algebraic integers. This improvement has a consequence for the search of Salem numbers that have a negative trace. The same method also gives a small improvement of the upper bound for the integer transfinite diameter of [0,1].

  5. Diagnostic criteria for hepatocellular carcinoma ⩽3 cm with hepatocyte-specific contrast-enhanced magnetic resonance imaging.

    PubMed

    Choi, Sang Hyun; Byun, Jae Ho; Lim, Young-Suk; Yu, Eunsil; Lee, So Jung; Kim, So Yeon; Won, Hyung Jin; Shin, Yong Moon; Kim, Pyo Nyun

    2016-05-01

    Current diagnostic imaging criteria for hepatocellular carcinoma (HCC) are dedicated to imaging with nonspecific extracellular contrast agents. This study aimed to evaluate diagnostic criteria for HCC ⩽3 cm on magnetic resonance imaging (MRI) with a hepatocyte-specific contrast agent through an inception cohort study. Of 291 patients with chronic liver disease and new nodules of 1-3 cm in diameter at surveillance ultrasonography, 295 solid nodules (194 HCCs, 98 benign nodules, and three other malignancies) in 198 patients with a confirmed final diagnosis or ⩾24 months follow-up were evaluated on gadoxetic acid-enhanced MRI. Through univariate and multivariate logistic regression analyses, various diagnostic criteria were developed by combining significant MRI findings for diagnosing HCC. The diagnostic performance of each criterion was compared with that of the European Association for the Study of the Liver (EASL) criteria. Four MRI findings (arterial-phase hyperintensity, transitional-phase hypointensity, hepatobiliary-phase hypointensity, and rim enhancement) were independently significant for diagnosis of HCC ⩽3 cm. For whole nodules, EASL criteria showed the best performance for diagnosing HCC (sensitivity, 83.5%; specificity, 81.2%). For nodules ⩽2 cm in diameter, a new criterion (arterial-phase hyperintensity and hepatobiliary-phase hypointensity) showed a significantly higher sensitivity than that of the EASL criteria (83.0% vs. 74.5%, p=0.008), without a significantly different specificity (76.7% vs. 81.1%, p=0.125). EASL criteria exhibit the best diagnostic performance for HCC ⩽3 cm on hepatocyte-specific contrast-enhanced MRI. A newly identified criterion (arterial-phase hyperintensity and hepatobiliary-phase hypointensity) may increase the diagnostic sensitivity of small (⩽2 cm) HCC. Copyright © 2016 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  6. [A Case of Gastric Cancer with Splenic Artery Aneurysm, Intraoperative ICG Fluorography Is Useful in Evaluating the Blood Flow of Stomach and Spleen].

    PubMed

    Usui, Kenji; Sakamoto, Kaoru; Akabane, Kentaro; Hayasaka, Kazuki; Mizuki, Toru; Yagi, Yutaka; Shirahata, Yasuhiro; Ichikawa, Hiroshi; Hanyu, Takaaki; Ishikawa, Takashi; Kameyama, Hitoshi; Suzuki, Satoshi; Saito, Kiyohiro; Wakai, Toshifumi

    2017-11-01

    An 81-year-oldwoman with advancedgastric cancer was referredto our hospital. Preoperative contrast-enhancedCT revealeda roundcalcification of the splenic hilum with 15mm in diameter as a splenic artery aneurysm. She underwent transcatheter arterial embolization(TAE)for the splenic artery aneurysm. Celiac artery angiography showedcollateral arterial network of the spleen from left gastric artery. Surgery for the gastric cancer was performed1 4 days after TAE. We cut the right gastric andbilateral epigastric arteries. After the left gastric artery clamping, we performedintraoperative indocyanine green(ICG)fluorography. ICG fluorography confirmedthat the bloodflow of the upper thirdof the stomach andspleen were maintained. We safely performed distal gastrectomy, and the postoperative course was uneventful.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mankovich, N.J.; Lambert, T.; Zrimec, T.

    A project is underway to develop automated methods of fusing cerebral magnetic resonance angiography (MRA) and x-ray angiography (XRA) for creating accurate visualizations used in planning treatment of vascular disease. The authors have developed a vascular phantom suitable for testing segmentation and fusion algorithms with either derived images (pseudo-MRA/pseudo-XRA) or actual MRA or XRA image sequences. The initial unilateral arterial phantom design, based on normal human anatomy, contains 48 tapering vascular segments with lumen diameters from 2.5 millimeter to 0.25 millimeter. The initial phantom used rapid prototyping technology (stereolithography) with a 0.9 millimeter vessel wall fabricated in an ultraviolet-cured plastic.more » The model fabrication resulted in a hollow vessel model comprising the internal carotid artery, the ophthalmic artery, and the proximal segments of the anterior, middle, and posterior cerebral arteries. The complete model was fabricated but the model`s lumen could not be cleared for vessels with less than 1 millimeter diameter. Measurements of selected vascular outer diameters as judged against the CAD specification showed an accuracy of 0.14 mm and precision (standard deviation) of 0.15 mm. The plastic vascular model produced provides a fixed geometric framework for the evaluation of imaging protocols and the development of algorithms for both segmentation and fusion.« less

  8. Anatomy of vastus lateralis muscle flap.

    PubMed

    Tayfur, Volkan; Magden, Orhan; Edizer, Mete; Atabey, Atay

    2010-11-01

    A vastus lateralis muscle flap is used as a pedicled and free flap. In this study, the vastus lateralis muscles of 15 adult formalin-fixed cadavers (30 cases) were dissected. The dominant pedicle was found to be descending branch of the lateral circumflex femoral artery. The mean diameter of the artery was found to be 2.1 mm. This pedicle was located 119.4 mm distal to the pubic symphysis. The mean length of the major pedicle was found to be 56.8 mm when the dominant pedicle was chosen to nourish the flap. The dominant pedicle entered the muscle 155.8 and 213.7 mm from the greater trochanter and the anterior superior iliac spine, respectively. The muscle had proximal minor pedicles from the ascending and transverse branches of lateral circumflex femoral artery. These arteries had mean diameters of 1.8 and 2.0 mm, respectively. The distal minor branches were present in all of the dissections. The distal branch had a mean diameter of 1.8 mm. The origin of this distal branch was located 83.7 mm proximal to the intercondylar line. The motor nerve of the vastus lateralis was found to be originating from femoral nerve. The nerve entered the muscle 194.6 mm from the anterior superior iliac spine.

  9. Anatomic vascular phantom for the verification of MRA and XRA visualization and fusion

    NASA Astrophysics Data System (ADS)

    Mankovich, Nicholas J.; Lambert, Timothy; Zrimec, Tatjana; Hiller, John B.

    1995-05-01

    A project is underway to develop automated methods of fusing cerebral magnetic resonance angiography (MRA) and x-ray angiography (XRA) for creating accurate visualizations used in planning treatment of vascular disease. We have developed a vascular phantom suitable for testing segmentation and fusion algorithms with either derived images (psuedo-MRA/psuedo-XRA) or actual MRA or XRA image sequences. The initial unilateral arterial phantom design, based on normal human anatomy, contains 48 tapering vascular segments with lumen diameters from 2.5 millimeter to 0.25 millimeter. The initial phantom used rapid prototyping technology (stereolithography) with a 0.9 millimeter vessel wall fabricated in an ultraviolet-cured plastic. The model fabrication resulted in a hollow vessel model comprising the internal carotid artery, the ophthalmic artery, and the proximal segments of the anterior, middle, and posterior cerebral arteries. The complete model was fabricated but the model's lumen could not be cleared for vessels with less than 1 millimeter diameter. Measurements of selected vascular outer diameters as judged against the CAD specification showed an accuracy of 0.14 mm and precision (standard deviation) of 0.15 mm. The plastic vascular model produced provides a fixed geometric framework for the evaluation of imaging protocols and the development of algorithms for both segmentation and fusion.

  10. Validation of the Simbionix PROcedure Rehearsal Studio sizing module: A comparison of software for endovascular aneurysm repair sizing and planning.

    PubMed

    Velu, Juliëtte F; Groot Jebbink, Erik; de Vries, Jean-Paul P M; Slump, Cornelis H; Geelkerken, Robert H

    2017-02-01

    An important determinant of successful endovascular aortic aneurysm repair is proper sizing of the dimensions of the aortic-iliac vessels. The goal of the present study was to determine the concurrent validity, a method for comparison of test scores, for EVAR sizing and planning of the recently introduced Simbionix PROcedure Rehearsal Studio (PRORS). Seven vascular specialists analyzed anonymized computed tomography angiography scans of 70 patients with an infrarenal aneurysm of the abdominal aorta, using three different sizing software packages Simbionix PRORS (Simbionix USA Corp., Cleveland, OH, USA), 3mensio (Pie Medical Imaging BV, Maastricht, The Netherlands), and TeraRecon (Aquarius, Foster City, CA, USA). The following measurements were included in the protocol: diameter 1 mm below the most distal main renal artery, diameter 15 mm below the lowest renal artery, maximum aneurysm diameter, and length from the most distal renal artery to the left iliac artery bifurcation. Averaged over the locations, the intraclass correlation coefficient is 0.83 for Simbionix versus 3mensio, 0.81 for Simbionix versus TeraRecon, and 0.86 for 3mensio versus TeraRecon. It can be concluded that the Simbionix sizing software is as precise as two other validated and commercially available software packages.

  11. Soft tissue models: easy and inexpensive flexible 3D printing as a help in surgical planning of cardiovascular disorders

    NASA Astrophysics Data System (ADS)

    Starosolski, Zbigniew; Ezon, David S.; Krishnamurthy, Rajesh; Dodd, Nicholas; Heinle, Jeffrey; Mckenzie, Dean E.; Annapragada, Ananth

    2017-03-01

    We developed a technology that allows a simple desktop 3D printer with dual extruder to fabricate 3D flexible models of Major AortoPulmonary Collateral Arteries. The study was designed to assess whether the flexible 3D printed models could help during surgical planning phase. Simple FDM 3D printers are inexpensive, versatile in use and easy to maintain, but complications arise when the designed model is complex and has tubular structures with small diameter less than 2mm. The advantages of FDM printers are cost and simplicity of use. We use precisely selected materials to overcome the obstacles listed above. Dual extruder allows to use two different materials while printing, which is especially important in the case of fragile structures like pulmonary vessels and its supporting structures. The latter should not be removed by hand to avoid a truncation of the model. We utilize the water soluble PVA as a supporting structure and Poro-Lay filament for flexible model of AortoPulmonary collateral arteries. Poro-Lay filament is different as compared to all the other flexible ones like polymer-based. Poro-Lay is rigid while printing and this allows printing of structures small in diameter. It achieves flexibility after washing out of printed model with water. It becomes soft in touch and gelatinous. Using both PVA and Poro-Lay gives a huge advantage allowing to wash out the supporting structures and achieve flexibility in one washing operation, saving time and avoiding human error with cleaning the model. We evaluated 6 models for MAPCAS surgical planning study. This approach is also cost-effective - an average cost of materials for print is less than $15; models are printed in facility without any delays. Flexibility of 3D printed models approximate soft tissues properly, mimicking Aortopulmonary collateral arteries. Second utilization models has educational value for both residents and patients' family. Simplification of 3D flexible process could help in other models of soft tissue pathologies like aneurysms, ventricular septal defects and other vascular anomalies.

  12. Enhanced Re-Endothelialization of Decellularized Rat Lungs

    PubMed Central

    Stabler, Collin T.; Caires, Luiz C.; Mondrinos, Mark J.; Marcinkiewicz, Cezary; Lazarovici, Philip; Wolfson, Marla R.

    2016-01-01

    Decellularized lung tissue has been recognized as a potential platform to engineer whole lung organs suitable for transplantation or for modeling a variety of lung diseases. However, many technical hurdles remain before this potential may be fully realized. Inability to efficiently re-endothelialize the pulmonary vasculature with a functional endothelium appears to be the primary cause of failure of recellularized lung scaffolds in early transplant studies. Here, we present an optimized approach for enhanced re-endothelialization of decellularized rodent lung scaffolds with rat lung microvascular endothelial cells (ECs). This was achieved by adjusting the posture of the lung to a supine position during cell seeding through the pulmonary artery. The supine position allowed for significantly more homogeneous seeding and better cell retention in the apex regions of all lobes than the traditional upright position, especially in the right upper and left lobes. Additionally, the supine position allowed for greater cell retention within large diameter vessels (proximal 100–5000 μm) than the upright position, with little to no difference in the small diameter distal vessels. EC adhesion in the proximal regions of the pulmonary vasculature in the decellularized lung was dependent on the binding of EC integrins, specifically α1β1, α2β1, and α5β1 integrins to, respectively, collagen type-I, type-IV, and fibronectin in the residual extracellular matrix. Following in vitro maturation of the seeded constructs under perfusion culture, the seeded ECs spread along the vascular wall, leading to a partial reestablishment of endothelial barrier function as inferred from a custom-designed leakage assay. Our results suggest that attention to cellular distribution within the whole organ is of paramount importance for restoring proper vascular function. PMID:26935764

  13. Effects of cadmium on the renal and skeletal muscle microcirculation in rats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang Chong.

    1990-01-01

    The effects of cadmium on the arteriolar diameters of the kidney and skeletal muscle were quantified, because of the hypertensive effect of cacmium. The effect of cacmium on the constrictor response of the renal arterioles to angiotensin II (Ang II) were also assessed. In vivo preparations of the rat hydronephrotic kidney and cremaster muscle were used for direct visualization of the microvessels with intravital television microscopy. Hydronephrosis was induced in twenty-seven male Wistar-Kyoto rats (150-180 g) by unilateral ureter ligation. The hydronephrotic kidney, with intact cortical circulation and innervation, was exteriorized in a specially designed bath for microcirculation observation 6-8more » weeks following the ureter ligation. The cremaster muscle experiments were conducted in another thirty-seven male WKY rats (120-180 g). Disparate effects of cadmium were observed in these two microcirculation beds. Topical cadmium (1.35 [mu]M-0.45 mM) increased the diameters of the pre- and postglomerular vessels in the hydronephrotic kidney maximally by 15-26%. Cadmium (0.27 mM) inhibited the Ang II response of the arterioles non-competitively. However, intraperitoneally injected cadmium (2 mg/kg), which significantly increased the mean arterial pressure, did not dilate the arterioles nor alter the Ang II response. On the other hand, cadmium (13.5 [mu]M-0.72 mM) constricted the larger arterioles in the cremaster muscle (60-160 [mu]m) concentration-dependently, but not small arterioles (15-30 [mu]m). In summary, topical cadmium dilates renal arterioles and decreases their reactivity to Ang II, but constricts the larger cremaster arterioles. The disparate effects of cadmium suggest different Ca[sup 2+] utilization mechanisms in different vascular beds. The construction of the cremaster arterioles may contribute to cadmium-induced hypertension by increasing peripheral resistance.« less

  14. The Tissue-Engineered Vascular Graft—Past, Present, and Future

    PubMed Central

    Pashneh-Tala, Samand; MacNeil, Sheila

    2016-01-01

    Cardiovascular disease is the leading cause of death worldwide, with this trend predicted to continue for the foreseeable future. Common disorders are associated with the stenosis or occlusion of blood vessels. The preferred treatment for the long-term revascularization of occluded vessels is surgery utilizing vascular grafts, such as coronary artery bypass grafting and peripheral artery bypass grafting. Currently, autologous vessels such as the saphenous vein and internal thoracic artery represent the gold standard grafts for small-diameter vessels (<6 mm), outperforming synthetic alternatives. However, these vessels are of limited availability, require invasive harvest, and are often unsuitable for use. To address this, the development of a tissue-engineered vascular graft (TEVG) has been rigorously pursued. This article reviews the current state of the art of TEVGs. The various approaches being explored to generate TEVGs are described, including scaffold-based methods (using synthetic and natural polymers), the use of decellularized natural matrices, and tissue self-assembly processes, with the results of various in vivo studies, including clinical trials, highlighted. A discussion of the key areas for further investigation, including graft cell source, mechanical properties, hemodynamics, integration, and assessment in animal models, is then presented. PMID:26447530

  15. CFD simulation of blood flow inside the corkscrew collaterals of the Buerger's disease.

    PubMed

    Sharifi, Alireza; Charjouei Moghadam, Mohammad

    2016-01-01

    Buerger's disease is an occlusive arterial disease that occurs mainly in medium and small vessels. This disease is associated with Tobacco usage. The existence of corkscrew collateral is one of the established characteristics of the Buerger's disease. In this study, the computational fluid dynamics (CFD) simulation of blood flow within the corkscrew artery of the Buerger's disease is conducted. The geometry of the artery is constructed based on the actual corkscrew artery of a patient diagnosed with the Buerger's disease. The blood properties are the same as the actual blood properties of the patient. The blood flow rate is taken from the available experimental data in the literature. The local velocity patterns, pressure and kinematic viscosity distributions in different segments of the corkscrew collateral artery was demonstrated and discussed for the first time for this kind of artery. The effects of non-Newtonian consideration for the blood viscosity behavior were investigated in different segments of the artery. Moreover, the variations of the blood flow patterns along the artery were investigated in details for each segment. It was found that the flow patterns were affected by the complex geometry of this artery in such a way that it could lead to the presence of sites that were prone to the accumulation of the flowing particles in blood like nicotine. Furthermore, due to the existence of many successive bends in this artery, the variations of kinematic viscosity along this artery were significant, therefore the non-Newtonian behavior of the blood viscosity must be considered.

  16. CFD simulation of blood flow inside the corkscrew collaterals of the Buerger’s disease

    PubMed Central

    Sharifi, Alireza; Charjouei Moghadam, Mohammad

    2016-01-01

    Introduction: Buerger’s disease is an occlusive arterial disease that occurs mainly in medium and small vessels. This disease is associated with Tobacco usage. The existence of corkscrew collateral is one of the established characteristics of the Buerger’s disease. Methods: In this study, the computational fluid dynamics (CFD) simulation of blood flow within the corkscrew artery of the Buerger’s disease is conducted. The geometry of the artery is constructed based on the actual corkscrew artery of a patient diagnosed with the Buerger’s disease. The blood properties are the same as the actual blood properties of the patient. The blood flow rate is taken from the available experimental data in the literature. Results: The local velocity patterns, pressure and kinematic viscosity distributions in different segments of the corkscrew collateral artery was demonstrated and discussed for the first time for this kind of artery. The effects of non-Newtonian consideration for the blood viscosity behavior were investigated in different segments of the artery. Moreover, the variations of the blood flow patterns along the artery were investigated in details for each segment. Conclusion: It was found that the flow patterns were affected by the complex geometry of this artery in such a way that it could lead to the presence of sites that were prone to the accumulation of the flowing particles in blood like nicotine. Furthermore, due to the existence of many successive bends in this artery, the variations of kinematic viscosity along this artery were significant, therefore the non-Newtonian behavior of the blood viscosity must be considered. PMID:27340623

  17. Rarefaction and blood pressure in systemic and pulmonary arteries

    PubMed Central

    OLUFSEN, METTE S.; HILL, N. A.; VAUGHAN, GARETH D. A.; SAINSBURY, CHRISTOPHER; JOHNSON, MARTIN

    2012-01-01

    The effects of vascular rarefaction (the loss of small arteries) on the circulation of blood are studied using a multiscale mathematical model that can predict blood flow and pressure in the systemic and pulmonary arteries. We augmented a model originally developed for the systemic arteries (Olufsen et al. 1998, 1999, 2000, 2004) to (a) predict flow and pressure in the pulmonary arteries, and (b) predict pressure propagation along the small arteries in the vascular beds. The systemic and pulmonary arteries are modelled as separate, bifurcating trees of compliant and tapering vessels. Each tree is divided into two parts representing the `large' and `small' arteries. Blood flow and pressure in the large arteries are predicted using a nonlinear cross-sectional area-averaged model for a Newtonian fluid in an elastic tube with inflow obtained from magnetic resonance measurements. Each terminal vessel within the network of the large arteries is coupled to a vascular bed of small `resistance' arteries, which are modelled as asymmetric structured trees with specified area and asymmetry ratios between the parent and daughter arteries. For the systemic circulation, each structured tree represents a specific vascular bed corresponding to major organs and limbs. For the pulmonary circulation, there are four vascular beds supplied by the interlobar arteries. This manuscript presents the first theoretical calculations of the propagation of the pressure and flow waves along systemic and pulmonary large and small arteries. Results for all networks were in agreement with published observations. Two studies were done with this model. First, we showed how rarefaction can be modelled by pruning the tree of arteries in the microvascular system. This was done by modulating parameters used for designing the structured trees. Results showed that rarefaction leads to increased mean and decreased pulse pressure in the large arteries. Second, we investigated the impact of decreasing vessel compliance in both large and small arteries. Results showed, that the effects of decreased compliance in the large arteries far outweigh the effects observed when decreasing the compliance of the small arteries. We further showed that a decrease of compliance in the large arteries results in pressure increases consistent with observations of isolated systolic hypertension, as occurs in ageing. PMID:22962497

  18. Prevalence and predictors of renal artery stenosis in patients undergoing peripheral and coronary angiography.

    PubMed

    Shukla, Anand N; Madan, Tarun H; Jayaram, Ashwal A; Kute, Vivek B; Rawal, Jayesh R; Manjunath, A P; Udhreja, Satyam

    2013-12-01

    Renal artery stenosis is a potential cause of secondary hypertension, ischemic nephropathy and end-stage renal disease. Atherosclerosis is by far the most common etiology of renal artery stenosis in elderly. We investigated whether the presence of significant atherosclerotic renal artery stenosis (ARAS) with luminal diameter narrowing ≥50 % could be predicted in patients undergoing peripheral and coronary angiography. The records of 3,500 consecutive patients undergoing simultaneous renal angiography along with peripheral and coronary angiography were reviewed. The patients with known renal artery disease were excluded. Prevalence of ARAS was 5.7 %. Significant ARAS (luminal diameter narrowing ≥50 %) was present in 139 patients (3.9 %). Hypertension with altered serum creatinine and triple-vessel CAD were associated with significant renal artery stenosis in multivariate analysis. No significant relationship between the involved coronary arteries like left anterior descending, left circumflex, right coronary artery and ARAS was found. Only hypertension and altered serum creatinine were associated with bilateral ARAS. Extent of CAD or risk factors like diabetes, hyperlipidemia or smoking did not predict the unilateral or bilateral ARAS. Prevalence of ARAS among the patients in routine cardiac catheterization was 5.7 %. Hypertension is closely associated with significant ARAS. Significant CAD in the form of triple-vessel disease and altered renal function tests are closely associated with ARAS. They predict the presence of significant renal artery stenosis in patients undergoing routine peripheral and coronary angiography. Moreover, hypertension and altered renal functions predict bilateral ARAS.

  19. Noncontrast-enhanced magnetic resonance renal angiography using a repetitive artery and venous labelling technique at 3 T: comparison with contrast-enhanced magnetic resonance angiography in subjects with normal renal function.

    PubMed

    Park, Sung Yoon; Kim, Chan Kyo; Kim, EunJu; Park, Byung Kwan

    2015-02-01

    To investigate the feasibility of noncontrast-enhanced MR angiography (NC-MRA) using the repetitive artery and venous labelling (RAVEL) technique to evaluate renal arteries compared to contrast-enhanced MR angiography (CE-MRA). Twenty-five subjects with normal renal function underwent NC-MRA using a RAVEL technique and CE-MRA at 3 T. Two independent readers analysed the MRA images. Image quality, number of renal arteries, presence or absence of an early branching vessel, and diameter of the main renal arteries were evaluated. The overall image quality of NC-MRA was fair or greater in 88% of right and 92% of left renal arteries, while it was 96% in both sides with CE-MRA. On NC-MRA, the number of renal arteries in all subjects was perfectly predicted by both readers. Sensitivity and specificity for predicting early branching vessels were 82% and 100% for reader 1 and 82% and 95% for reader 2. Inter-modality agreement for comparing the diameters of main renal arteries was good or excellent at all segments for both readers. Inter-reader agreement was moderate or good at all segments except at the right distal segment on NC-MRA. NC-MRA with the RAVEL technique at 3 T may have comparable diagnostic feasibility for evaluating renal arteries compared to CE-MRA. • Accurate pre-treatment evaluation of renal artery anatomy helps clinical decision-making. • NC-MRA using RAVEL offers acceptable imaging quality for renal artery evaluation. • The 3 T RAVEL technique provides excellent diagnostic performance for renal artery evaluation. • The 3 T RAVEL technique may be an alternative to contrast-enhanced MRA.

  20. Diagnostic capability of gadoxetate disodium-enhanced liver MRI for diagnosis of hepatocellular carcinoma: comparison with multi-detector CT.

    PubMed

    Toyota, Naoyuki; Nakamura, Yuko; Hieda, Masashi; Akiyama, Naoko; Terada, Hiroaki; Matsuura, Noriaki; Nishiki, Masayo; Kono, Hirotaka; Kohno, Hiroshi; Irei, Toshimitsu; Yoshikawa, Yukinobu; Kuraoka, Kazuya; Taniyama, Kiyomi; Awai, Kazuo

    2013-09-01

    The purpose of this study was to evaluate the diagnostic capability of gadoxetate disodium (Gd-EOB)-MRI for the detection of hepatocellular carcinoma (HCC) compared with multidetector CT (MDCT). Fifty patients with 57 surgically proven HCCs who underwent Gd-EOB-MRI and MDCT from March 2008 to June 2011 were evaluated. Two observers evaluated MR and CT on a lesion-by-lesion basis. We analyzed sensitivity by grading on a 5-point scale, the degree of arterial enhancement and the differences in histological grades in the diffusion-weighted images (DWI). The results showed that the sensitivity of Gd-EOB-MRI was higher than that of MDCT especially for HCCs that were 1 cm in diameter or smaller. The hepatobiliary phase was useful for the detecting of small HCC. We had few cases in which it was difficult to judge HCC in the arterial enhancement between MRI and MDCT. In the diffusion-weighted image, well differentiated HCC tended to show a low signal intensity, and poorly differentiated HCC tended to show a high signal intensity. In moderately differentiated HCC's, the mean diameter of the high signal intensity group was larger than that of the low signal intensity group (24.5 mm vs. 15.8 mm). In conclusion, Gd-EOB-MRI tended to show higher sensitivity compared to MDCT in the detection of HCC.

  1. Robot-based tele-echography: clinical evaluation of the TER system in abdominal aortic exploration.

    PubMed

    Martinelli, Thomas; Bosson, Jean-Luc; Bressollette, Luc; Pelissier, Franck; Boidard, Eric; Troccaz, Jocelyne; Cinquin, Philippe

    2007-11-01

    The TER system is a robot-based tele-echography system allowing remote ultrasound examination. The specialist moves a mock-up of the ultrasound probe at the master site, and the robot reproduces the movements of the real probe, which sends back ultrasound images and force feedback. This tool could be used to perform ultrasound examinations in small health care centers or from isolated sites. The objective of this study was to prove, under real conditions, the feasibility and reliability of the TER system in detecting abdominal aortic and iliac aneurysms. Fifty-eight patients were included in 2 centers in Brest and Grenoble, France. The remote examination was compared with the reference standard, the bedside examination, for aorta and iliac artery diameter measurement, detection and description of aneurysms, detection of atheromatosis, the duration of the examination, and acceptability. All aneurysms (8) were detected by both techniques as intramural thrombosis and extension to the iliac arteries. The interobserver correlation coefficient was 0.982 (P < .0001) for aortic diameters. The rate of concordance between 2 operators in evaluating atheromatosis was 84% +/- 11% (95% confidence interval). Our study on 58 patients suggests that the TER system could be a reliable, acceptable, and effective robot-based system for performing remote abdominal aortic ultrasound examinations. Research is continuing to improve the equipment for general abdominal use.

  2. A new design concept for knitted external vein-graft support mesh.

    PubMed

    Singh, Charanpreet; Wang, Xungai

    2015-08-01

    Autologous vein-graft failure significantly limits the long-term efficacy of coronary artery bypass procedures. The major cause behind this complication is biomechanical mismatch between the vein and coronary artery. The implanted vein experiences a sudden increase (10-12 fold) in luminal pressures. The resulting vein over-distension or 'ballooning' initiates wall thickening phenomenon and ultimate occlusion. Therefore, a primary goal in improving the longevity of a coronary bypass procedure is to inhibit vein over-distension using mechanical constriction. The idea of using an external vein-graft support mesh has demonstrated sustained benefits and wide acceptance in experimental studies. Nitinol based knitted structures have offered more promising mechanical features than other mesh designs owing to their unique loosely looped construction. However, the conventional plain knit construction still exhibits limitations (radial compliance, deployment ease, flexibility, and bending stresses) which limit this design from proving its real clinical advantage. The new knitted mesh design presented in this study is based on the concept of composite knitting utilising high modulus (nitinol and polyester) and low modulus (polyurethane) material components. The experimental comparison of the new design with a plain knit design demonstrated significant improvement in biomechanical (compliance, flexibility, extensibility, viscoelasticity) and procedural (deployment limit) parameters. The results are indicative of the promising role of new mesh in restoring the lost compliance and pulsatility of vein-graft at high arterial pressures. This way it can assist in controlled vein-graft remodelling and stepwise restoration of vein mechanical homoeostasis. Also, improvement in deployment limit parameter offers more flexibility for a surgeon to use a wide range of vein diameters, which may otherwise be rendered unusable for a plain knit mesh. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Predictors of radio-cephalic arteriovenous fistulae patency in an Asian population.

    PubMed

    Joseph Lo, Zhiwen; Tay, Wee Ming; Lee, Qinyi; Chua, Jia Long; Tan, Glenn Wei Leong; Chandrasekar, Sadhana; Narayanan, Sriram

    2016-09-21

    To identify predictors of arteriovenous fistula (AVF) patency in Asian patients with autogenous radio-cephalic arteriovenous fistula (RCAVF). Retrospective review of 436 RCAVFs created between 2009 and 2013. Predictors of patency were identified with univariate and multivariate analysis. Kaplan-Meier survival analysis and log-rank test were used to calculate patency rates. Overall secondary patency rate was 72% at 12 months, 69% at 24 months, 58% at 36 months, 57% at 48 months, 56% at 60 months and 54% at 72 months. Univariate analysis showed that factors which predict for patency include male gender (p = 0.003), good diabetic control (p = 0.025), aspirin use (p = 0.031), pre-dialysis status (p = 0.037), radial artery diameter (p = 0.029) and non-calcified radial arteries (p = 0.002). Age (p = 0.866), cephalic vein diameter (p = 0.630) and surgeon grade (p = 0.472) did not predict for primary AVF failure. Multivariate analysis revealed the male gender to be an independent predictor for patency (odds ratio 1.99, p = 0.01). Subset analysis showed a significantly larger average radial artery diameter of 2.3 mm amongst males, as compared to 1.9 mm amongst females (p = 0.001) and no statistical difference in the average cephalic vein diameter. Within our Asian study population, 12-month patency rate of RCAVF is 72%, 69% at 24 months, 58% at 36 months, 57% at 48 months, 56% at 60 months and 54% at 72 months. Male gender is an independent predictor for RCAVF patency. In females or patients with calcified radial arteries, a more proximal AVF should be considered.

  4. Dependence of diameters and oxygen saturation of retinal vessels on visual field damage and age in primary open-angle glaucoma.

    PubMed

    Ramm, Lisa; Jentsch, Susanne; Peters, Sven; Sauer, Lydia; Augsten, Regine; Hammer, Martin

    2016-05-01

    To investigate the interrelationship between the oxygen supply of the retina and its regulation with the severity of primary open-angle glaucoma (POAG). Central retinal artery (CRAE) and vein (CRVE) diameters and oxygen saturation of peripapillary retinal vessels in 41 patients suffering from POAG (64.1 ± 12.9 years) and 40 healthy volunteers (63.6 ± 14.1 years) were measured using the retinal vessel analyzer. All measures were taken before and during flicker light stimulation. The mean retinal nerve fiber layer thickness (RNFLT) was determined by OCT and the visual field mean defect (MD) was identified using perimetry. In glaucoma patients, CRAE (r = -0.48 p = 0.002) and CRVE (r = -0.394 p = 0.014) at baseline were inversely related to MD, while arterial and venous oxygen saturation showed no significant dependence on the severity of the damage. However, the flicker light-induced change in arterio-venous difference in oxygen saturation was correlated with the MD (r = 0.358 p = 0.027). The diameters of arteries and veins at baseline decreased with reduction of the mean RNFLT (arteries: r = 0.718 p < 0.001; veins: r = 0.685 p < 0.001). Vessel diameters showed a strong correlation with RNFLT and MD. This, as well as the reduction of stimulation-induced change in arterio-venous oxygen saturation difference with visual field loss, may be explained by a reduction of the retinal metabolic demand with progressive loss of neuronal tissue in glaucoma. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  5. One year Rat Study of iBTA-induced "Microbiotube" Microvascular Grafts With an Ultra-Small Diameter of 0.6 mm.

    PubMed

    Ishii, Daizo; Enmi, Jun-Ichiro; Iwai, Ryosuke; Kurisu, Kaoru; Tatsumi, Eisuke; Nakayama, Yasuhide

    2018-06-01

    The world's smallest calibre "microbiotube" vascular graft was recently developed, with an inner diameter of 0.6 mm. It was formed using in-body tissue architecture (iBTA) and has a high degree of patency and capacity for regeneration in the acute phase, 1 month after implantation. This consecutive study investigated the compatibility and stability of microbiotubes in the chronic phase of implantation for 12 months for potential application in microsurgery. This was an in vivo experimental study. The microbiotubes were prepared by embedding the mould subcutaneously in rats for 2 months. Allogenic microbiotubes (n = 16) were implanted into the bilateral femoral arteries (inner diameter 0.5 mm) of eight Wistar rats in an end to end anastomosis manner for 12 months. Follow up 7-Tesla magnetic resonance angiograms were performed every 3 months. Histological observation was performed 12 months after implantation. All patent grafts (n = 12, patency 75%) one month after implantation maintained their patency up to 12 months without any abnormal morphological changes or calcification. Histological observation at 12 months showed that layered α-smooth muscle actin positive cells with a monolayer luminal covering of endothelial cells had formed from the proximal to the distal anastomoses. A thin elastic fibre layer formed in the luminal area. After implantation, all components of the microbiotube were similar to those of a native artery. This study suggests that microbiotubes have high compatibility, stability, and durability as replacement grafts over the short to mid-term period. Copyright © 2018 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.

  6. Intraluminal ultrasound guidance of transverse laser coronary atherectomy

    NASA Astrophysics Data System (ADS)

    Aretz, H. Thomas; Martinelli, Michael A.; LeDet, Earl G.; Sedlacek, Tomas; Hatch, G. F.; Gregg, Richard E.

    1990-07-01

    A coronary laser atherectomy system combining laser delivery and ultrasonic imaging capability is described. The system is being developed by Intra-Sonix, Inc. to treat severe stenoses. The imaging system provides the clinician with the guidance needed to remove substantial plaque without perforation. The ultrasound transducers and laser optics are mounted in a small (less than 4 F), flexible catheter, that is deliverable over a standard guidewire (0.016 inch). The laser and ultrasound beams are directed at the artery wall to permit debulking of lesions and ultrasonic depth profiling of the tissue structure throughout the thickness of the artery. This allows the physician to determine the level of therapy to be applied and to monitor the plaque removal as the therapy progresses. The precise location of the ultrasound and laser beams in the artery is determined by a navigation system. Navigation data are processed electronically in conjunction with ultrasound data to produce real-time cross-sectional and longitudinal images of the artery wall at selected locations, which are updated as the catheter progresses through the vessel lumen. Results of in vitro tests on human atherosclerotic arteries and early in vivo experiments in a canine-human xenograft model showing image construction and radial laser delivery are discussed.

  7. High-definition computed tomography for coronary artery stents imaging: Initial evaluation of the optimal reconstruction algorithm.

    PubMed

    Cui, Xiaoming; Li, Tao; Li, Xin; Zhou, Weihua

    2015-05-01

    The aim of this study was to evaluate the in vivo performance of four image reconstruction algorithms in a high-definition CT (HDCT) scanner with improved spatial resolution for the evaluation of coronary artery stents and intrastent lumina. Thirty-nine consecutive patients with a total of 71 implanted coronary stents underwent coronary CT angiography (CCTA) on a HDCT (Discovery CT 750 HD; GE Healthcare) with the high-resolution scanning mode. Four different reconstruction algorithms (HD-stand, HD-detail; HD-stand-plus; HD-detail-plus) were applied to reconstruct the stented coronary arteries. Image quality for stent characterization was assessed. Image noise and intrastent luminal diameter were measured. The relationship between the measurement of inner stent diameter (ISD) and the true stent diameter (TSD) and stent type were analysed. The stent-dedicated kernel (HD-detail) offered the highest percentage (53.5%) of good image quality for stent characterization and the highest ratio (68.0±8.4%) of visible stent lumen/true stent lumen for luminal diameter measurement at the expense of an increased overall image noise. The Pearson correlation coefficient between the ISD and TSD measurement and spearman correlation coefficient between the ISD measurement and stent type were 0.83 and 0.48, respectively. Compared with standard reconstruction algorithms, high-definition CT imaging technique with dedicated high-resolution reconstruction algorithm provides more accurate stent characterization and intrastent luminal diameter measurement. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  8. Pediatric Patients with High Pulmonary Arterial Pressure in Congenital Heart Disease Have Increased Tracheal Diameters Measured by Computed Tomography.

    PubMed

    Ohashi, Nobuko; Imai, Hidekazu; Seino, Yutaka; Baba, Hiroshi

    2017-12-06

    Determination of the appropriate tracheal tube size using formulas based on age or height often is inaccurate in pediatric patients with congenital heart disease (CHD), particularly in those with high pulmonary arterial pressure (PAP). Here, the authors compared tracheal diameters between pediatric patients with CHD with high PAP and low PAP. Retrospective clinical study. Hospital. Pediatric patients, from birth to 6 months of age, requiring general anesthesia and tracheal intubation who underwent computed tomography were included. Patients with mean pulmonary artery pressure >25 mmHg were allocated to the high PAP group, and the remaining patients were allocated to the low PAP group. The primary outcome was the tracheal diameter at the cricoid cartilage level, and the secondary goal was to observe whether the size of the tracheal tube was appropriate compared with that obtained using predictable formulas based on age or height. The mean tracheal diameter was significantly larger in the high PAP group than in the low PAP group (p < 0.01). Pediatric patients with high PAP required a larger tracheal tube size than predicted by formulas based on age or height (p = 0.04 for age and height). Pediatric patients with high PAP had larger tracheal diameters than those with low PAP and required larger tracheal tubes compared with the size predicted using formulas based on age or height. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Constitutive laws with damage effect for the human great saphenous vein.

    PubMed

    Li, Wenguang

    2018-05-01

    Strain energy-based constitutive laws with damage effect were proposed by using existing both uniaxial tensile test and tubular biaxial inflation test data on the human great saphenous vein (GSV) segments. These laws were applied into GSV coronary artery bypass grafts (CABG) by employing a thin-walled vessel model to evaluate their passive biomechanical performance under coronary artery physiological conditions at a fixed axial pre-stretch. At a peak systolic pressure in 100-150 mmHg, a 20-33% GSV diameter dilation was predicted with the law based on tubular biaxial inflation test data and agreed well with 25% dilation in clinical observation in comparison with as small as 2-4% dilation estimated with the law based on uniaxial tensile test data. The constitutive law generated by tubular biaxial inflation test data was mostly suitable for GSV CABG under coronary artery physiological conditions than that based on uniaxial tensile test results. With these laws, the fibre ultimate stretch was extracted from uniaxial tensile test data and the structural sub-failure/damage threshold of 1.0731 was decided for the human GSV. GSV fibres could exhibit damage effect but unlikely undergo a structure failure/break, suggesting a damage factor might exist during CABG arterialization. The damage in GSV tissue might initiate or contribute to early remodelling of CABG after implantation. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Endothelial microparticles and vascular parameters in subjects with and without arterial hypertension and coronary artery disease.

    PubMed

    Sansone, Roberto; Baaken, Maximilian; Horn, Patrick; Schuler, Dominik; Westenfeld, Ralf; Amabile, Nicolas; Kelm, Malte; Heiss, Christian

    2018-08-01

    Endothelial microparticles (EMPs) are markers of endothelial injury and activation. The role of EMPs in arterial hypertension is not well understood and EMPs are increased both in arterial hypertension and coronary artery disease (CAD). The data presented here show EMPs as defined by CD31 + /41 - , CD62e + , and CD144 + surface markers and vascular hemodynamic parameters including office and central blood pressure, heart rate, aortic augmentation index, pulse wave velocity, flow-mediated dilation, nitroglycerin-mediated dilation, brachial artery diameter, hyperemic wall shear stress, and laser Doppler perfusion of the cutaneous microcirculation of normotensives and hypertensives with and without CAD.

  11. Tumor necrosis factor-α enhances microvascular tone and reduces blood flow in the cochlea via enhanced sphingosine-1-phosphate signaling.

    PubMed

    Scherer, Elias Q; Yang, Jingli; Canis, Martin; Reimann, Katrin; Ivanov, Karolina; Diehl, Christian D; Backx, Peter H; Wier, W Gil; Strieth, Sebastian; Wangemann, Philine; Voigtlaender-Bolz, Julia; Lidington, Darcy; Bolz, Steffen-Sebastian

    2010-11-01

    We sought to demonstrate that tumor necrosis factor (TNF)-α, via sphingosine-1-phosphate signaling, has the potential to alter cochlear blood flow and thus, cause ischemic hearing loss. We performed intravital fluorescence microscopy to measure blood flow and capillary diameter in anesthetized guinea pigs. To measure capillary diameter ex vivo, capillary beds from the gerbil spiral ligament were isolated from the cochlear lateral wall and maintained in an organ bath. Isolated gerbil spiral modiolar arteries, maintained and transfected in organ culture, were used to measure calcium sensitivity (calcium-tone relationship). In a clinical study, a total of 12 adult patients presenting with typical symptoms of sudden hearing loss who were not responsive or only partially responsive to prednisolone treatment were identified and selected for etanercept treatment. Etanercept (25 mg s.c.) was self-administered twice a week for 12 weeks. TNF-α induced a proconstrictive state throughout the cochlear microvasculature, which reduced capillary diameter and cochlear blood flow in vivo. In vitro isolated preparations of the spiral modiolar artery and spiral ligament capillaries confirmed these observations. Antagonizing sphingosine-1-phosphate receptor 2 subtype signaling (by 1 μmol/L JTE013) attenuated the effects of TNF-α in all models. TNF-α activated sphingosine kinase 1 (Sk1) and induced its translocation to the smooth muscle cell membrane. Expression of a dominant-negative Sk1 mutant (Sk1(G82D)) eliminated both baseline spiral modiolar artery calcium sensitivity and TNF-α effects, whereas a nonphosphorylatable Sk1 mutant (Sk1(S225A)) blocked the effects of TNF-α only. A small group of etanercept-treated, hearing loss patients recovered according to a 1-phase exponential decay (half-life=1.56 ± 0.20 weeks), which matched the kinetics predicted for a vascular origin. TNF-α indeed reduces cochlear blood flow via activation of vascular sphingosine-1-phosphate signaling. This integrates hearing loss into the family of ischemic microvascular pathologies, with implications for risk stratification, diagnosis, and treatment.

  12. Blood pressure regulation V: in vivo mechanical properties of precapillary vessels as affected by long-term pressure loading and unloading.

    PubMed

    Eiken, Ola; Mekjavic, Igor B; Kölegård, Roger

    2014-03-01

    Recent studies are reviewed, concerning the in vivo wall stiffness of arteries and arterioles in healthy humans, and how these properties adapt to iterative increments or sustained reductions in local intravascular pressure. A novel technique was used, by which arterial and arteriolar stiffness was determined as changes in arterial diameter and flow, respectively, during graded increments in distending pressure in the blood vessels of an arm or a leg. Pressure-induced increases in diameter and flow were smaller in the lower leg than in the arm, indicating greater stiffness in the arteries/arterioles of the leg. A 5-week period of intermittent intravascular pressure elevations in one arm reduced pressure distension and pressure-induced flow in the brachial artery by about 50%. Conversely, prolonged reduction of arterial/arteriolar pressure in the lower body by 5 weeks of sustained horizontal bedrest, induced threefold increases of the pressure-distension and pressure-flow responses in a tibial artery. Thus, the wall stiffness of arteries and arterioles are plastic properties that readily adapt to changes in the prevailing local intravascular pressure. The discussion concerns mechanisms underlying changes in local arterial/arteriolar stiffness as well as whether stiffness is altered by changes in myogenic tone and/or wall structure. As regards implications, regulation of local arterial/arteriolar stiffness may facilitate control of arterial pressure in erect posture and conditions of exaggerated intravascular pressure gradients. That increased intravascular pressure leads to increased arteriolar wall stiffness also supports the notion that local pressure loading may constitute a prime mover in the development of vascular changes in hypertension.

  13. The Influence of Positioning of the Nellix Endovascular Aneurysm Sealing System on Suprarenal and Renal Flow: An In Vitro Study.

    PubMed

    Boersen, Johannes T; Groot Jebbink, Erik; Van de Velde, Lennart; Versluis, Michel; Lajoinie, Guillaume; Slump, Cornelius H; de Vries, Jean-Paul P M; Reijnen, Michel M P J

    2017-10-01

    To examine the influence of device positioning and infrarenal neck diameter on flow patterns in the Nellix endovascular aneurysm sealing (EVAS) system. The transition of the aortic flow lumen into two 10-mm-diameter stents after EVAS creates a mismatched area. Flow recirculation may affect local wall shear stress (WSS) profiles and residence time associated with atherosclerosis and thrombosis. To examine these issues, 7 abdominal aortic aneurysm flow phantoms were created, including 3 unstented controls and 3 stented models with infrarenal neck diameters of 24, 28, and 32 mm. Stents were positioned within the instructions for use (IFU). Another 28-mm model was created to evaluate lower positioning of the stents outside the IFU (28-mm LP). Flow was visualized using optical particle imaging velocimetry (PIV) and quantified by time-averaged WSS (TAWSS), oscillatory shear index (OSI), and relative residence time (RRT) in the aorta at the anteroposterior (AP) midplane, lateral midplane, and renal artery AP midplane levels. Flow in the aorta AP midplane was similar in all models. Vortices were observed in the stented models in the lateral midplane near the anterior and posterior walls. In the 32-mm IFU and 28-mm LP models, a steady state of vortices appeared, with varying location during a cycle. In all models, a low TAWSS (<10 -2 Pa) was observed at the anterior wall of the aorta with peak OSI of 0.5 and peak RRT of 10 4 Pa -1 . This region was more proximally located in the stented models. The 24- and 28-mm IFU models showed flow with a higher velocity at the renal artery inflow compared to controls. TAWSS in the renal artery was lower near the orifice in all models, with the largest area in the 24-mm IFU model. OSI and RRT in the renal artery were near zero for all models. EVAS enhances vorticity proximal to the seal zone, especially with lower positioning of the device and in larger neck diameters. Endobags just below the renal artery affect the flow profile in a minor area of this artery in 24- and 28-mm necks, while lower stent positioning does not influence the renal artery flow profile.

  14. Altered active but not passive properties of mesenteric resistance arteries from the vitamin E-deprived rat

    PubMed Central

    Davidge, Sandra T; Gandley, Robin E; McLaughlin, Margaret K

    1998-01-01

    We tested the hypothesis that lowering antioxidant protection through dietary vitamin E deprivation would alter active and passive mechanical properties in resistance arteries of the rat. Specifically, we hypothesized that vascular tone in isolated mesenteric arteries of the vitamin E-deprived rats would be altered due to impaired endothelial influences of nitric oxide and/or prostaglandins.Lumen diameter and wall thickness were measured in pressurized arteries (≈amp;250 μm diameter) from control (n=9) and vitamin E deprived (n=9) Sprague-Dawley female rats by use of a dimension analysing system.Treatment with a cyclo-oxygenase inhibitor (meclofenamate) did not affect the basal vascular tone in either group. Treatment with a nitric oxide synthase inhibitor (NG-methyl-L-arginine) caused a significant increase in basal tone only in the vitamin E-deprived rats (% tone: 6.2±1.1 vs 1.2±0.3%; P<0.05). When tone was induced to 25% of the initial diameter with phenylephrine, treatment with the nitric oxide synthase inhibitor resulted in a greater potentiated tone in the vitamin E-deprived rats compared to the controls (26.5±2.7 vs 16.4±3.4%; P<0.05); suggesting a greater nitric oxide affect in the vessels from the vitamin E-deprived rats. Meclofenamate treatment in the induced tone arteries significantly relaxed (−17.4±4.0%; P<0.05) only the arteries from the vitamin E-deprived rats, indicating that a vasoconstrictor was modifying tone. The passive characteristics of distensibility and stress-strain relationship were not different between the two groups of rats.In summary, vitamin E deprivation in the rat enhanced the modulation of vascular tone by both the nitric oxide and cyclo-oxygenase pathways but did not alter passive characteristics of mesenteric arteries. PMID:9489616

  15. Brachial artery vasoreactivity is associated with cross-sectional and longitudinal anatomical measures of atherosclerosis in postmenopausal women with coronary artery disease

    PubMed Central

    Gatto, Nicole M.; Hodis, Howard N.; Liu, Chao-Ran; Liu, Chi-Hua; Mack, Wendy J.

    2009-01-01

    Background The diagnostic and prognostic importance of brachial artery flow-mediated dilation (BFMD) for cardiovascular disease (CVD) is not certain and associations between BFMD and recognized measures of atherosclerosis have not been well established. Methods We investigated cross-sectional and longitudinal correlations between repeated measures of BFMD and quantitative coronary artery angiographic (QCA) measurements of average percent diameter stenosis, number of lesions and minimum luminal diameter (MLD), and ultrasonographic measurement of carotid artery intima-media thickness (CIMT) in an ethnically diverse cohort of postmenopausal women (n = 132) with coronary artery disease (CAD). Subjects were participants in a 3-year randomized, placebo-controlled clinical trial, testing the efficacy of hormone therapy on atherosclerosis progression. Associations between BFMD and QCA measures, and between BFMD and CIMT were examined using measurements from the same study visit. Results BFMD was significantly inversely correlated with coronary artery stenosis at baseline (β = −1.21% [S.E.(β) = 0.38], p = 0.002). BFMD levels significantly predicted rate of change in CIMT over the trial period (β = −0.76 μm/year [S.E.(β) = 0.29], p = 0.008). Conclusions Physiological and anatomical measures of atherosclerosis are correlated among postmenopausal women with CAD, which provides some validation of BFMD as a measure of atherosclerosis in high-risk populations. PMID:17803999

  16. Breast feeding in infancy and arterial endothelial function later in life. The Cardiovascular Risk in Young Finns Study.

    PubMed

    Järvisalo, M J; Hutri-Kähönen, N; Juonala, M; Mikkilä, V; Räsänen, L; Lehtimäki, T; Viikari, J; Raitakari, O T

    2009-05-01

    Breast feeding in infancy may be associated with reduced cardiovascular morbidity in adulthood. We examined the association between breast feeding in infancy and arterial function and structure in adulthood in a population-based cohort of Finnish adults. Noninvasive ultrasound was used to measure brachial artery flow-mediated dilatation (FMD), carotid artery intima-media thickness (IMT) and carotid artery compliance (CAC) in 1667 young adults participating in the Cardiovascular Risk in Young Finns Study with data on early nutrition. Maximal FMD was higher in breast-fed men compared to formula-fed men (7.2+/-4.0 vs 5.9+/-3.4%, P=0.029) while no differences were seen between breast-fed and formula-fed women (8.9+/-4.5 vs 8.8+/-5.0%, P=0.84). In men, the multivariable correlates of FMD included the group variable for breast feeding (P=0.014), birth weight (P=0.043), waist circumference (P<0.001) and baseline brachial artery diameter (P<0.001). In women, the multivariable correlates of FMD were birth weight (P=0.02), waist circumference (P<0.001) and brachial artery baseline diameter (P<0.001). Breast feeding was not significantly associated with IMT or CAC in multivariable models. Adult men who have been breast fed have better brachial endothelial function compared to men who have been formula fed.

  17. Triamcinolone Acetonide Selectively Inhibits Angiogenesis in Small Blood Vessels and Decreases Vessel Diameter within the Vascular Tree

    NASA Technical Reports Server (NTRS)

    McKay, Terri L.; Gredeon, Dan J.; Vickerman, Mary B.; Hylton, alan G.; Ribita, Daniela; Olar, Harry H.; Kaiser, Peter K.; Parsons-Wingerter, Patricia

    2007-01-01

    The steroid triamcinolone acetonide (TA) is a potent anti-angiogenesis drug used to treat retinal vascular diseases that include diabetic retinopathy, vascular occlusions and choroidal neovascularization. To quantify the effects of TA on branching morphology within the angiogenic microvascular tree of the chorioallantoic membrane (CAM) of quail embryos. Increasing concentrations of TA (0-16 ng/ml) were applied topically on embryonic day 7 (E7) to the chorioallantoic membrane (CAM) of quail embryos cultured in Petri dishes, and incubated for an additional 24 or 48 hours until fixation. Binary (black/white) microscopic images of arterial end points were quantified by VESGEN software (for Generational Analysis of Vessel Branching) to obtain major vascular parameters that include vessel diameter (Dv), fractal dimension (Df), tortuosity (Tv) and densities of vessel area, length, number and branch point (Av, Lv, Nv and Brv). For assessment of specific changes in vascular morphology induced by TA, the VESGEN software automatically segmented the vascular tree into branching generations (G1...G10) according to changes in vessel diameter and branching. Vessel density decreased significantly up to 34% as the function of increasing concentration of TA according to Av, Lv, Brv, Nv and Df. TA selectively inhibited the growth of new, small vessels, because Lv decreased from 13.14plus or minus 0.61 cm/cm2 for controls to 8.012 plus or minus 0.82 cm/cm2 at 16 ng TA/ml in smaller branching generations (G7-G10), and for Nv from 473.83 plus or minus 29.85 cm(-)2 to 302.32 plus or minus 33.09 cm-()2. In contrast, vessel diameter (Dv) decreased throughout the vascular tree (G1-G10).

  18. Characteristics and Fate of Systemic Artery Aneurysm after Kawasaki Disease.

    PubMed

    Hoshino, Shinsuke; Tsuda, Etsuko; Yamada, Osamu

    2015-07-01

    To determine the long-term outcome of systemic artery aneurysms (SAAs) after Kawasaki disease (KD). We investigated the characteristics and the fate of SAAs in 20 patients using medical records and angiograms. The age of onset of KD ranged from 1 month to 20 months. The interval from the onset of KD to the latest angiogram ranged from 16 months to 24 years. The regression rate of peripheral artery aneurysm and the frequency of stenotic lesions were analyzed by the Kaplan-Meier method in 11 patients who had undergone initial angiography within 4 months. The mean duration of fever was 24 ± 12 days. All 20 patients had at least 1 symmetric pair of aneurysms in bilateral peripheral arteries, and 16 patients had multiple SAAs. The distributions of SAAs was as follows: brachial artery, 30; common iliac artery, 20; internal iliac artery, 21; abdominal aortic aneurysm, 7; and others, 29. The frequencies of regression of SAA and of the occurrence of stenotic lesions at 20 years after the onset of KD were 51% and 25%, respectively (n = 42). The diameter of all SAAs in the acute phase leading to stenotic lesions in the late period was >10 mm. SAAs occurred symmetrically and were multiple in younger infants and those with severe acute vasculitis. The fate of SAAs resembles that of coronary artery aneurysms, and depends on the diameter during the acute phase. Larger SAAs can lead to stenotic lesions in the late period. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Evaluation of carotid intima-media thickness and carotid arterial stiffness in children with adenotonsillar hypertrophy.

    PubMed

    Çiftel, Murat; Demir, Berrin; Kozan, Günay; Yılmaz, Osman; Kahveci, Hasan; Kılıç, Ömer

    2016-02-01

    Adenotonsillar hypertrophy can produce cardiopulmonary disease in children. However, it is unclear whether adenotonsillar hypertrophy causes atherosclerosis. This study evaluated carotid intimamedia thickness and carotid arterial stiffness in children with adenotonsillar hypertrophy. The study included 40 children with adenotonsillar hypertrophy (age: 5-10 years) and 36 healthy children with similar age and body mass index. Systolic blood pressure, diastolic blood pressure, and pulse pressure were measured in all subjects. Carotid intima-media thickness, carotid arterial systolic diameter, and carotid arterial diastolic diameter were measured using a high-resolution ultrasound device. Based on these measurements, carotid arterial strain, carotid artery distensibility, beta stiffness index, and elasticity modulus were calculated. Carotid intima-media thickness was greater in children with adenotonsillar hypertrophy (0.36±0.05 mm vs. 0.34±0.04 mm, P=0.02) compared to healthy controls. Beta stiffness index (3.01±1.22 vs. 2.98±0.98, P=0.85), elasticity modulus (231.39±99.23 vs. 226.46±83.20, P=0.88), carotid arterial strain (0.17±0.06 vs. 0.17±0.04, P=0.95), and carotid artery distensibility (13.14±3.88 vs. 12.92±3.84, P=0.75) were similar between children with adenotonsillar hypertrophy and the healthy controls. The present study revealed increased carotid intima-media thickness in children with adenotonsillar hypertrophy. The risk of subclinical atherosclerosis may be higher in children with adenotonsillar hypertrophy.

  20. Vessel calibre and flow splitting relationships at the internal carotid artery terminal bifurcation.

    PubMed

    Chnafa, C; Bouillot, P; Brina, O; Delattre, B M A; Vargas, M I; Lovblad, K O; Pereira, V M; Steinman, D A

    2017-11-01

    Vessel lumen calibres and flow rates are thought to be related by mathematical power laws, reflecting the optimization of cardiac versus metabolic work. While these laws have been confirmed indirectly via measurement of branch calibres, there is little data confirming power law relationships of flow distribution to branch calibres at individual bifurcations. Flow rates and diameters of parent and daughter vessels of the internal carotid artery terminal bifurcation were determined, via robust and automated methods, from 4D phase-contrast magnetic resonance imaging and 3D rotational angiography of 31 patients. Junction exponents were 2.06  ±  0.44 for relating parent to daughter branch diameters (geometrical exponent), and 2.45  ±  0.75 for relating daughter branch diameters to their flow division (flow split exponent). These exponents were not significantly different, but showed large inter- and intra-individual variations, and with confidence intervals excluding the theoretical optimum of 3. Power law fits of flow split versus diameter ratio and pooled flow rates versus diameters showed exponents of 2.17 and 1.96, respectively. A significant negative correlation was found between age and the geometrical exponent (r  =  -0.55, p  =  0.003) but not the flow split exponent. We also found a dependence of our results on how lumen diameter is measured, possibly explaining some of the variability in the literature. Our study confirms that, on average, division of flow to the middle and anterior cerebral arteries is related to these vessels' relative calibres via a power law, but it is closer to a square law than a cube law as commonly assumed.

  1. Vertebral Artery Diameter and Flow: Nature or Nurture.

    PubMed

    Tarnoki, Adam Domonkos; Fejer, Bence; Tarnoki, David Laszlo; Littvay, Levente; Lucatelli, Pierleone; Cirelli, Carlo; Fanelli, Fabrizio; Sacconi, Beatrice; Fagnani, Corrado; Medda, Emanuela; Farina, Filippo; Meneghetti, Giorgio; Horvath, Tamas; Pucci, Giacomo; Schillaci, Giuseppe; Stazi, Maria Antonietta; Baracchini, Claudio

    2017-09-01

    In contrast with the carotid arteries, the vertebral arteries (VAs) show considerable variation in length, caliber, and vessel course. This study investigated whether the variation in diameter and flow characteristics of the VAs might be inherited. A total of 172 Italian twins from Padua, Perugia, and Terni (54 monozygotic, 32 dizygotic) recruited from the Italian Twin Registry underwent B-mode and pulsed-wave Doppler ultrasound assessment of their VAs. VA diameters, peak systolic velocity (PSV) and end diastolic velocity (EDV) were assessed at the level of a horizontal V2 segment. Univariate quantitative genetic modeling was performed. Fourteen percent of the sample had VA hypoplasia. Within pair correlation in monozygotic twins was higher than in dizygotics (.552 vs. .229) for VA diameter. Age- and sex-adjusted genetic effect, under the most parsimonious model, accounted for 54.7% (95% CI: 42.2-69.1%) of the variance of VA diameter, and unshared environmental effect for 45.3% (95% CI: 30.9-57.8%). No heritability was found for the PSV of VA, but shared (34.1%; 95% CI: 16.7-53.7%) and unshared (65.9%; 95% CI: 45.9-83.1%) environmental factors determined the variance. EDV of VA is moderately genetically influenced (42.4%; 95% CI: 16.1-64.9%) and also determined by the unshared environment (57.6%; 95% CI: 34.7-83.7%). The diameter of the VAs is moderately genetically determined. Different factors influence the PSV and EDV of VAs, which may highlight the complex hemodynamic background of VA flow and help to understand the vertebral flow anomalies found by ultrasound. Copyright © 2017 by the American Society of Neuroimaging.

  2. Impaired flow-induced dilation in mesenteric resistance arteries from mice lacking vimentin.

    PubMed Central

    Henrion, D; Terzi, F; Matrougui, K; Duriez, M; Boulanger, C M; Colucci-Guyon, E; Babinet, C; Briand, P; Friedlander, G; Poitevin, P; Lévy, B I

    1997-01-01

    The intermediate filament vimentin might play a key role in vascular resistance to mechanical stress. We investigated the responses to pressure (tensile stress) and flow (shear stress) of mesenteric resistance arteries perfused in vitro from vimentin knockout mice. Arteries were isolated from homozygous (Vim-/-, n = 14) or heterozygous vimentin-null mice (Vim+/-, n = 5) and from wild-type littermates (Vim+/+, n = 9). Passive arterial diameter (175+/-15 micron in Vim+/+ at 100 mmHg) and myogenic tone were not affected by the absence of vimentin. Flow-induced (0-150 microl/min) dilation (e. g., 19+/-3 micron dilation at 150 mmHg in Vim+/+) was significantly attenuated in Vim-/- mice (13+/-2 micron dilation, P < 0.01). Acute blockade of nitric oxide synthesis (NG-nitro- L-arginine, 10 microM) significantly decreased flow-induced dilation in both groups, whereas acute blockade of prostaglandin synthesis (indomethacin, 10 microM) had no significant effect. Mean blood pressure, in vivo mesenteric blood flow and diameter, and mesenteric artery media thickness or media to lumen ratio were not affected by the absence of vimentin. Thus, the absence of vimentin decreased selectively the response of resistance arteries to flow, suggesting a role for vimentin in the mechanotransduction of shear stress. PMID:9389758

  3. [Applied anatomy study and clinical application of great saphenous veno-saphenous neurocutaneous vascular flap].

    PubMed

    Li, Zelong; Ding, Zihai; Wang, Peixin; Xie, Yibo; Zeng, Bo

    2006-03-01

    To provide the anatomic basis for defect repair of the knee, leg, foot and ankle with great saphenous veno-saphenous neurocutaneous vascular island flaps. The origin, diameter, branches, distribution and anastomoses of the saphenous artery and saphenous neurocutaneous vascular were observed on 20 sides of adult leg specimens and 4 fresh cadaver voluntary legs. Another 4 fresh cadaver voluntary legs were radiographed with a soft X-ray system after the intravenous injection of Vermilion and cross-sections under profound fascial, other hand, micro-anatomic examination was also performed in these 4 fresh cadaver legs. The soft tissue defects in lower extremity, upper extremity, heel or Hucou in hand were repaired with the proximal or distal pedicle flaps or free flaps in 18 patients (12 males and 6 females,aging from 7 to 53 years). The defect was caused by trauma, tumour, ulcer and scar. The locations were Hucou (1 case), upper leg (3 cases), lower extremity and heal (14 cases). Of then, 7 cases were complicated by bone exposure, 3 cases by tendon exposure and 1 case by steel espouse, the defect size were 4 cm x 4 cm to 7 cm x 13 cm. The flap sizes were 4 cm x 6 cm to 8 cm x 15 cm, which pedicle length was 8-11 cm with 2.5-4.0 cm fascia and 1-2 cm skin at width. Genus descending genicular artery began from 9.33 +/- 0.81 cm away from upper the condyles medialis, it branched saphenous artery accompanying saphenous nerve descendent. And saphenous artery reached the surface of the skin 7.21 +/- 0.82 cm away from lower the condyles medialis, and anastomosed with the branches of tibialis posterior artery, like "Y" or "T" pattern. The chain linking system of arteries were found accompanying along the great saphenous vein as saphenous nerve, and then a axis blood vessel was formed. The small artery of only 0.05-0.10 mm in diameter, distributed around the great saphenous vein within 5-8 mm and arranged parallelly along the vein like water wave in soft X-ray film. All proximal flaps, distal pedicle flaps and free flaps survived well. The appearance, sensation and function were satisfactory in 14 patients after a follow-up of 6-12 months. The great saphenous vein as well as saphenous neurocutaneous has a chain linking system vascular net. A flap with the vascular net can be transplanted by free, by reversed pedicle, or by direct pedicle to repair the wound of upper leg and foot. A superficial vein-superficial neurocutaneous vascular flap with abundance blood supply and without sacrificing a main artery is a favourite method in repair of soft tissue defects in foot and lower extremity.

  4. Brachial artery vasomotion and transducer pressure effect on measurements by active contour segmentation on ultrasound

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cary, Theodore W.; Sultan, Laith R.; Sehgal, Chandra M., E-mail: sehgalc@uphs.upenn.edu

    Purpose: To use feed-forward active contours (snakes) to track and measure brachial artery vasomotion on ultrasound images recorded in both transverse and longitudinal views; and to compare the algorithm's performance in each view. Methods: Longitudinal and transverse view ultrasound image sequences of 45 brachial arteries were segmented by feed-forward active contour (FFAC). The segmented regions were used to measure vasomotion artery diameter, cross-sectional area, and distention both as peak-to-peak diameter and as area. ECG waveforms were also simultaneously extracted frame-by-frame by thresholding a running finite-difference image between consecutive images. The arterial and ECG waveforms were compared as they traced eachmore » phase of the cardiac cycle. Results: FFAC successfully segmented arteries in longitudinal and transverse views in all 45 cases. The automated analysis took significantly less time than manual tracing, but produced superior, well-behaved arterial waveforms. Automated arterial measurements also had lower interobserver variability as measured by correlation, difference in mean values, and coefficient of variation. Although FFAC successfully segmented both the longitudinal and transverse images, transverse measurements were less variable. The cross-sectional area computed from the longitudinal images was 27% lower than the area measured from transverse images, possibly due to the compression of the artery along the image depth by transducer pressure. Conclusions: FFAC is a robust and sensitive vasomotion segmentation algorithm in both transverse and longitudinal views. Transverse imaging may offer advantages over longitudinal imaging: transverse measurements are more consistent, possibly because the method is less sensitive to variations in transducer pressure during imaging.« less

  5. Brachial artery vasomotion and transducer pressure effect on measurements by active contour segmentation on ultrasound.

    PubMed

    Cary, Theodore W; Reamer, Courtney B; Sultan, Laith R; Mohler, Emile R; Sehgal, Chandra M

    2014-02-01

    To use feed-forward active contours (snakes) to track and measure brachial artery vasomotion on ultrasound images recorded in both transverse and longitudinal views; and to compare the algorithm's performance in each view. Longitudinal and transverse view ultrasound image sequences of 45 brachial arteries were segmented by feed-forward active contour (FFAC). The segmented regions were used to measure vasomotion artery diameter, cross-sectional area, and distention both as peak-to-peak diameter and as area. ECG waveforms were also simultaneously extracted frame-by-frame by thresholding a running finite-difference image between consecutive images. The arterial and ECG waveforms were compared as they traced each phase of the cardiac cycle. FFAC successfully segmented arteries in longitudinal and transverse views in all 45 cases. The automated analysis took significantly less time than manual tracing, but produced superior, well-behaved arterial waveforms. Automated arterial measurements also had lower interobserver variability as measured by correlation, difference in mean values, and coefficient of variation. Although FFAC successfully segmented both the longitudinal and transverse images, transverse measurements were less variable. The cross-sectional area computed from the longitudinal images was 27% lower than the area measured from transverse images, possibly due to the compression of the artery along the image depth by transducer pressure. FFAC is a robust and sensitive vasomotion segmentation algorithm in both transverse and longitudinal views. Transverse imaging may offer advantages over longitudinal imaging: transverse measurements are more consistent, possibly because the method is less sensitive to variations in transducer pressure during imaging.

  6. Brachial artery vasomotion and transducer pressure effect on measurements by active contour segmentation on ultrasound

    PubMed Central

    Cary, Theodore W.; Reamer, Courtney B.; Sultan, Laith R.; Mohler, Emile R.; Sehgal, Chandra M.

    2014-01-01

    Purpose: To use feed-forward active contours (snakes) to track and measure brachial artery vasomotion on ultrasound images recorded in both transverse and longitudinal views; and to compare the algorithm's performance in each view. Methods: Longitudinal and transverse view ultrasound image sequences of 45 brachial arteries were segmented by feed-forward active contour (FFAC). The segmented regions were used to measure vasomotion artery diameter, cross-sectional area, and distention both as peak-to-peak diameter and as area. ECG waveforms were also simultaneously extracted frame-by-frame by thresholding a running finite-difference image between consecutive images. The arterial and ECG waveforms were compared as they traced each phase of the cardiac cycle. Results: FFAC successfully segmented arteries in longitudinal and transverse views in all 45 cases. The automated analysis took significantly less time than manual tracing, but produced superior, well-behaved arterial waveforms. Automated arterial measurements also had lower interobserver variability as measured by correlation, difference in mean values, and coefficient of variation. Although FFAC successfully segmented both the longitudinal and transverse images, transverse measurements were less variable. The cross-sectional area computed from the longitudinal images was 27% lower than the area measured from transverse images, possibly due to the compression of the artery along the image depth by transducer pressure. Conclusions: FFAC is a robust and sensitive vasomotion segmentation algorithm in both transverse and longitudinal views. Transverse imaging may offer advantages over longitudinal imaging: transverse measurements are more consistent, possibly because the method is less sensitive to variations in transducer pressure during imaging. PMID:24506648

  7. CT features and common causes of arc of Riolan expansion: an analysis with 64-detector-row computed tomographic angiography

    PubMed Central

    Xie, Yuanliang; Jin, Chaolin; Zhang, Shutong; Wang, Xiang; Jiang, Yanping

    2015-01-01

    Objective: To study the manifestations of arc of Riolan expansion (ARE) using multi-detector computed tomography angiography (MDCTA). Materials and methods: The manifestations and clinical data of 626 consecutive mesentery CTA images were retrospectively analyzed. The 47 cases with ARE and 47 patients without expansion were involved. The average diameter of arc of Riolan was measured. Two radiologists after reaching consensus analyzed the shapes of mesenteric artery, CT findings and the occurrence and causes of ARE. Results: The mean diameter of arc of Riolan was 1.2 mm, 4.6 mm, 2.5 mm, 2.3 mm, 1.9 mm, 2.5 mm, and 2.0 mm at baseline and following obstruction of superior mesenteric artery (SMA), stenosis of SMA, obstruction of inferior mesenteric artery (IMA), stenosis of IMA, colon cancer, and active ulcerative colitis, respectively. The expansion of arc of Riolan was the most significant following obstruction of SMA. The diameters of arc of Riolan were significantly different between the upward flow group and the downward or the two-way flow groups, and between the colon tumor group and the active ulcerative colitis group. CT findings such as bowel wall thickening, contrast enhancement, intestinal obstruction, marginal artery expansion, lymph node enlargement varied and were help to identify the cause of ARE. Conclusions: ARE often suggests the occurrence of obstructed intestinal feeding artery or intestinal lesions. MDCTA can clearly display the situation of arc of Riolan and collateral circulation, and together with CT symptoms, can guide the selection of diagnosis and treatment schemes in clinic. PMID:26064208

  8. Relation between diameter and flow in major branches of the arch of the aorta.

    PubMed

    Zamir, M; Sinclair, P; Wonnacott, T H

    1992-11-01

    In the analysis of arterial branching the classical "cube law' has provided a working model for the relation between the diameter of a blood vessel and the flow which the vessel carries on a long-term basis. The law has shown good agreement with biological data, but questions remain regarding its applicability to all levels of the arterial tree. The present study tests the hypothesis that the cube law may not be valid in the first few generations of the arterial tree, where vessel capacitance and gross anatomy may play important roles. Biological data have shown some support for this hypothesis in the past but the heterogeneity characteristic of past data has not allowed a conclusive test so far. We present new data which have been obtained from the same location on the arterial tree and in sufficient number to make this test possible for the first time. Also, while past tests have been based primarily on correlation of the measured data with an assumed power law, we show here that this can be misleading. The present data allow a simpler test which does not involve correlation and which leads to more direct conclusions. For the vessels surveyed, the results show unequivocally that the relation between diameter and flow is governed by a 'square law' rather than the classical cube law. Coupled with past findings this suggests that the square law may apply at the first few levels of the arterial tree, while the cube law continues from there to perhaps the precapillary levels.

  9. Curative effect and mechanism of radiofrequency ablation nucleoplasty in the treatment of cervical vertigo.

    PubMed

    Yin, Hai-Dong; Zhang, Xin-Mei; Huang, Ming-Guang; Chen, Wei; Song, Yang; Du, Qing-Jun; Wu, Yu-Ning; Yang, Ruo-Bin

    2017-04-01

    This study aims to investigate the curative effects and mechanism of radiofrequency ablation nucleoplasty in the treatment of cervical vertigo. A total of 27 patients diagnosed with cervical vertigo from January 2012 to October 2014 received treatment of radiofrequency ablation nucleoplasty. The narrow-side vertebral artery diameters were examined by using Philips 1.5-T body dual-gradient MRI system. The haemodynamic parameters were detected by using transcranial Doppler sonography. Both of the vertebral artery diameters and haemodynamic parameters were recorded and compared before and after treatment. The curative effects in early post-operative application were evaluated according to the Nagashima standards. Radiofrequency ablation nucleoplasty was performed in a total of 59 cervical discs in 27 patients. The average operation time was 42.7 min, and the symptoms of 92.6% patients were alleviated after radiofrequency ablation nucleoplasty post-operation application. There was no significant difference in the narrow-side vertebral artery diameters before and after treatment in both Group A (p = 0.12) and Group B (p = 0.48); however, the blood flow velocity was significantly higher than that before treatment in both Group A (p = 0.01) and Group B (p = 0.03), respectively. Radiofrequency ablation nucleoplasty improves the blood flow in the narrow-side vertebral artery and illustrates the therapeutic effect on cervical vertigo in patients who have no direct compression of the vertebral artery. Advances in knowledge: Radiofrequency intradiscal nucleoplasty can be used as a minimally invasive procedure for treating cervical vertigo.

  10. Hypercholesterolemia increases vasospasm resulting from basilar artery subarachnoid hemorrhage in rabbits which is attenuated by Vitamin E

    PubMed Central

    Sasani, Mehdi; Yazgan, Burak; Celebi, Irfan; Aytan, Nurgul; Catalgol, Betul; Oktenoglu, Tunc; Kaner, Tuncay; Ozer, Nesrin Kartal; Ozer, Ali Fahir

    2011-01-01

    Background: Aneurysm rupture results in subarachnoid hemorrhage (SAH) with subsequent vasospasm in the cerebral and cerebellar major arteries. In recent years, there has been increasing evidence that hypercholesterolemia plays a role in the pathology of SAH. It is known that hypercholesterolemia is one of the major risk factors for the development of atherosclerosis. Among the factors that have been found to retard the development of atherosclerosis is the intake of a sufficient amount of Vitamin E. An inverse association between serum Vitamin E and coronary heart disease mortality has been demonstrated in epidemiologic studies. Therefore, we tested, in an established model of enhanced cholesterol feed in rabbits, the effects of hypercholesterolemia on vasospasm after SAH by using computed tomography (CT) angiograms of the rabbit basilar artery; in addition, we tested the effects of Vitamin E on these conditions, which have not been studied up to now. Methods: In this study rabbits were divided into 3 major groups: control, cholesterol fed, and cholesterol + Vitamin E fed. Hypercholesterolemia was induced by a 2% cholesterol-containing diet. Three rabbit groups were fed rabbit diet; one group was fed a diet that also contained 2% cholesterol and another group was fed a diet containing 2% cholesterol and they received i.m. injections of 50 mg/kg of Vitamin E. After 8 weeks, SAH was induced by the double-hemorrhage method and distilled water was injected into cisterna magna. Blood was taken to measure serum cholesterol and Vitamin E levels. Basilar artery samples were taken for microscopic examination. CT angiography and measurement of basilar artery diameter were performed at days 0 and 3 after SAH. Results: Two percent cholesterol diet supplementation for 8 weeks resulted in a significant increase in serum cholesterol levels. Light microscopic analysis of basilar artery of hypercholesterolemic rabbits showed disturbances in the subendothelial and medial layers, degeneration of elastic fibers in the medial layer from endothelial cell desquamation, and a reduction of waves in the endothelial layer. However, the cholesterol + Vitamin E group did not exhibit these changes. The mean diameter of the basilar artery after SAH induction in the cholesterol-treated group was decreased 47% compared with the mean diameter of the control group. This value was less affected in cholesterol + Vitamin E-treated rabbits, which decreased 18% compared with the mean diameter of the control group. Conclusions: Hypercholesterolemia-related changes in the basilar artery aggravate vasospasm after SAH. Adding Vitamin E to cholesterol-treated rabbits decreased the degree of vasospasm following SAH in the rabbit basilar artery SAH model. We suggest that Vitamin E supplements and a low cholesterol diet may potentially diminish SAH complicated by vasospasm in high-risk patients. PMID:21451728

  11. Risk factors for neurological worsening and symptomatic watershed infarction in internal carotid artery aneurysm treated by extracranial-intracranial bypass using radial artery graft.

    PubMed

    Matsukawa, Hidetoshi; Tanikawa, Rokuya; Kamiyama, Hiroyasu; Tsuboi, Toshiyuki; Noda, Kosumo; Ota, Nakao; Miyata, Shiro; Oda, Jumpei; Takeda, Rihee; Tokuda, Sadahisa; Kamada, Kyousuke

    2016-08-01

    OBJECT The revascularization technique, including bypass created using the external carotid artery (ECA), radial artery (RA), and M2 portion of middle cerebral artery (MCA), has remained indispensable for treatment of complex aneurysms. To date, it remains unknown whether diameters of the RA, superficial temporal artery (STA), and C2 portion of the internal carotid artery (ICA) and intraoperative MCA blood pressure have influences on the outcome and the symptomatic watershed infarction (WI). The aim of the present study was to evaluate the factors for the symptomatic WI and neurological worsening in patients treated by ECA-RA-M2 bypass for complex ICA aneurysm with therapeutic ICA occlusion. METHODS The authors measured the sizes of vessels (RA, C2, M2, and STA) and intraoperative MCA blood pressure (initial, after ICA occlusion, and after releasing the RA graft bypass) in 37 patients. Symptomatic WI was defined as presence of the following: postoperative new neurological deficits, WI on postoperative diffusion-weighted imaging, and ipsilateral cerebral blood flow reduction on SPECT. Neurological worsening was defined as the increase in 1 or more modified Rankin Scale scores. First, the authors performed receiver operating characteristic curve analysis for continuous variables and the binary end point of the symptomatic WI. The clinical, radiological, and physiological characteristics of patients with and without the symptomatic WI were compared using the log-rank test. Then, the authors compared the variables between patients with and without neurological worsening at discharge and at the 12-month follow-up examination or last hospital visit. RESULTS Symptomatic WI was observed in 2 (5.4%) patients. The mean MCA pressure after releasing the RA graft (< 55 mm Hg; p = 0.017), mean (MCA pressure after releasing the RA graft)/(initial MCA pressure) (< 0.70 mm Hg; p = 0.032), and mean cross-sectional area ratio ([RA/C2 diameter](2) < 0.40 mm [p < 0.0001] and [STA/C2 diameter](2) < 0.044 mm [p < 0.0001]) were related to the symptomatic WI. All preoperatively independent patients remained independent (modified Rankin Scale score < 3). After adjusting for age and sex, left operative side (p = 0.0090 and 0.038) and perforating artery ischemia (p = 0.0050 and 0.022) were related to neurological worsening at discharge (11 [29%] patients) and at the 12-month follow-up or last hospital visit (8 [22%] patients). CONCLUSIONS Results of the present study showed that the vessel diameter and intraoperative MCA pressure had impacts on the symptomatic WI and that operative side and perforating artery ischemia were related to neurological worsening in patients with complex ICA aneurysms treated by ECA-RA-M2 bypass.

  12. Brain arterial aging and its relationship to Alzheimer dementia

    PubMed Central

    Honig, Lawrence; Elkind, Mitchell S.V.; Mohr, Jay P.; Goldman, James; Dwork, Andrew J.; Morgello, Susan; Marshall, Randolph S.

    2016-01-01

    Objective: To test the hypothesis that brain arterial aging is associated with the pathologic diagnosis of Alzheimer disease (AD). Methods: Brain large arteries were assessed for diameter, gaps in the internal elastic lamina (IEL), luminal stenosis, atherosclerosis, and lumen-to-wall ratio. Elastin, collagen, and amyloid were assessed with Van Gieson, trichrome, and Congo red staining intensities, and quantified automatically. Brain infarcts and AD (defined pathologically) were assessed at autopsy. We created a brain arterial aging (BAA) score with arterial characteristics associated with aging after adjusting for demographic and clinical variables using cross-sectional generalized linear models. Results: We studied 194 autopsied brains, 25 (13%) of which had autopsy evidence of AD. Brain arterial aging consisted of higher interadventitial and lumen diameters, thickening of the wall, increased prevalence of IEL gaps, concentric intima thickening, elastin loss, increased amyloid deposition, and a higher IEL proportion without changes in lumen-to-wall ratio. In multivariable analysis, a high IEL proportion (B = 1.96, p = 0.030), thick media (B = 3.50, p = 0.001), elastin loss (B = 6.16, p < 0.001), IEL gaps (B = 3.14, p = 0.023), and concentric intima thickening (B = 7.19, p < 0.001) were used to create the BAA score. Adjusting for demographics, vascular risk factors, atherosclerosis, and brain infarcts, the BAA score was associated with AD (B = 0.022, p = 0.002). Conclusions: Aging of brain large arteries is characterized by arterial dilation with a commensurate wall thickening, elastin loss, and IEL gaps. Greater intensity of arterial aging was associated with AD independently of atherosclerosis and brain infarcts. Understanding the drivers of arterial aging may advance the knowledge of the pathophysiology of AD. PMID:26984942

  13. Brain arterial aging and its relationship to Alzheimer dementia.

    PubMed

    Gutierrez, Jose; Honig, Lawrence; Elkind, Mitchell S V; Mohr, Jay P; Goldman, James; Dwork, Andrew J; Morgello, Susan; Marshall, Randolph S

    2016-04-19

    To test the hypothesis that brain arterial aging is associated with the pathologic diagnosis of Alzheimer disease (AD). Brain large arteries were assessed for diameter, gaps in the internal elastic lamina (IEL), luminal stenosis, atherosclerosis, and lumen-to-wall ratio. Elastin, collagen, and amyloid were assessed with Van Gieson, trichrome, and Congo red staining intensities, and quantified automatically. Brain infarcts and AD (defined pathologically) were assessed at autopsy. We created a brain arterial aging (BAA) score with arterial characteristics associated with aging after adjusting for demographic and clinical variables using cross-sectional generalized linear models. We studied 194 autopsied brains, 25 (13%) of which had autopsy evidence of AD. Brain arterial aging consisted of higher interadventitial and lumen diameters, thickening of the wall, increased prevalence of IEL gaps, concentric intima thickening, elastin loss, increased amyloid deposition, and a higher IEL proportion without changes in lumen-to-wall ratio. In multivariable analysis, a high IEL proportion (B = 1.96, p = 0.030), thick media (B = 3.50, p = 0.001), elastin loss (B = 6.16, p < 0.001), IEL gaps (B = 3.14, p = 0.023), and concentric intima thickening (B = 7.19, p < 0.001) were used to create the BAA score. Adjusting for demographics, vascular risk factors, atherosclerosis, and brain infarcts, the BAA score was associated with AD (B = 0.022, p = 0.002). Aging of brain large arteries is characterized by arterial dilation with a commensurate wall thickening, elastin loss, and IEL gaps. Greater intensity of arterial aging was associated with AD independently of atherosclerosis and brain infarcts. Understanding the drivers of arterial aging may advance the knowledge of the pathophysiology of AD. © 2016 American Academy of Neurology.

  14. Bare-metal stenting of large coronary arteries in ST-elevation myocardial infarction is associated with low rates of target vessel revascularization.

    PubMed

    Shugman, Ibrahim M; Hee, Leia; Mussap, Christian J; Diu, Patrick; Lo, Sidney; Hopkins, Andrew P; Nguyen, Phong; Taylor, David; Rajaratnam, Rohan; Leung, Dominic; Thomas, Liza; Juergens, Craig P; French, John K

    2013-04-01

    During percutaneous coronary intervention (PCI) performed in the emergent setting of ST-segment elevation myocardial infarction (STEMI), uncertainty about patients' ability to comply with 12 months dual antiplatelet therapy after drug-eluting stenting is common, and thus, selective bare-metal stent (BMS) deployment could be an attractive strategy if this achieved low target vessel revascularization (TVR) rates in large infarct-related arteries (IRAs) (≥3.5 mm). To evaluate this hypothesis, among 1,282 patients with STEMI who underwent PCI during their initial hospitalization, we studied 1,059 patients (83%) who received BMS, of whom 512 (48%) had large IRAs ≥3.5 mm in diameter, 333 (31%) had IRAs 3 to 3.49 mm, and 214 (20%) had IRAs <3 mm. At 1 year, TVR rate in patients with BMS was 5.8% (2.2% with large BMS [≥3.5 mm], 9.2% with BMS 3-3.49 mm [intermediate], and 9.0% with BMS <3.0 mm [small], P < .001). The rates of death/reinfarction among patients with large BMS compared with intermediate BMS or small BMS were lower (6.6% vs 11.7% vs 9.0%, P = .042). Among patients who received BMS, the independent predictors of TVR at 1 year were the following: vessel diameter <3.5 mm (odds ratio [OR] 4.39 [95% CI 2.24-8.60], P < .001), proximal left anterior descending coronary artery lesions (OR 1.89 [95% CI 1.08-3.31], P = .027), hypertension (OR 2.01 [95% CI 1.17-3.438], P = .011), and prior PCI (OR 3.46 [95% CI 1.21-9.85], P = .02). The predictors of death/myocardial infarction at 1 year were pre-PCI cardiogenic shock (OR 8.16 [95% CI 4.16-16.01], P < .001), age ≥65 years (OR 2.63 [95% CI 1.58-4.39], P < .001), left anterior descending coronary artery culprit lesions (OR 1.95 [95% CI 1.19-3.21], P = .008), female gender (OR 1.93 [95% CI 1.12-3.32], P = .019), and American College of Cardiology/American Heart Association lesion classes B2 and C (OR 2.17 [95% CI 1.10-4.27], P = .026). Bare-metal stent deployment in STEMI patients with IRAs ≥3.5 mm was associated with low rates of TVR. Their use in this setting warrants comparison with second-generation drug-eluting stenting deployment in future randomized clinical trials. Copyright © 2013 Mosby, Inc. All rights reserved.

  15. Measurement of radioactivity concentration in blood by using newly developed ToT LuAG-APD based small animal PET tomograph.

    PubMed

    Malik, Azhar H; Shimazoe, Kenji; Takahashi, Hiroyuki

    2013-01-01

    In order to obtain plasma time activity curve (PTAC), input function for almost all quantitative PET studies, patient blood is sampled manually from the artery or vein which has various drawbacks. Recently a novel compact Time over Threshold (ToT) based Pr:LuAG-APD animal PET tomograph is developed in our laboratory which has 10% energy resolution, 4.2 ns time resolution and 1.76 mm spatial resolution. The measured value of spatial resolution shows much promise for imaging the blood vascular, i.e; artery of diameter 2.3-2.4mm, and hence, to measure PTAC for quantitative PET studies. To find the measurement time required to obtain reasonable counts for image reconstruction, the most important parameter is the sensitivity of the system. Usually small animal PET systems are characterized by using a point source in air. We used Electron Gamma Shower 5 (EGS5) code to simulate a point source at different positions inside the sensitive volume of tomograph and the axial and radial variations in the sensitivity are studied in air and phantom equivalent water cylinder. An average sensitivity difference of 34% in axial direction and 24.6% in radial direction is observed when point source is displaced inside water cylinder instead of air.

  16. Topical Menthol, Ice, Peripheral Blood Flow, and Perceived Discomfort

    PubMed Central

    Topp, Robert; Ledford, Elizabeth R.; Jacks, Dean E.

    2013-01-01

    Context: Injury management commonly includes decreasing arterial blood flow to the affected site in an attempt to reduce microvascular blood flow and edema and limit the induction of inflammation. Applied separately, ice and menthol gel decrease arterial blood flow, but the combined effects of ice and menthol gel on arterial blood flow are unknown. Objectives: To compare radial artery blood flow, arterial diameter, and perceived discomfort before and after the application of 1 of 4 treatment conditions. Design: Experimental crossover design. Setting: Clinical laboratory. Participants or Other Participants: Ten healthy men, 9 healthy women (mean age = 25.68 years, mean height = 1.73 m, mean weight = 76.73 kg). Intervention(s): Four treatment conditions were randomly applied for 20 minutes to the right forearm of participants on 4 different days separated by at least 24 hours: (1) 3.5 mL menthol gel, (2) 0.5 kg of crushed ice, (3) 3.5 mL of menthol gel and 0.5 kg of crushed ice, or (4) no treatment (control). Main Outcome Measure(s): Using high-resolution ultrasound, we measured right radial artery diameter (cm) and blood flow (mL/min) every 5 minutes for 20 minutes after the treatment was applied. Discomfort with the treatment was documented using a 1-to-10 intensity scale. Results: Radial artery blood flow decreased (P < .05) from baseline in the ice (−20% to −24%), menthol (−17% to −24%), and ice and menthol (−36% to −39%) treatments but not in the control (3% to 9%) at 5, 10, and 15 minutes. At 20 minutes after baseline, only the ice (−27%) and combined ice and menthol (−38%) treatments exhibited reductions in blood flow (P < .05). Discomfort was less with menthol than with the ice treatment at 5, 10, and 20 minutes after application (P < .05). Arterial diameter and heart rate did not change. Conclusions: The application of 3.5 mL of menthol was similar to the application of 0.5 kg of crushed ice in reducing peripheral blood flood. Combining crushed ice with menthol appeared to have an additive effect on reducing blood flow. PMID:23672386

  17. Conduit Artery Diameter During Exercise Is Enhanced After Local, but Not Remote, Ischemic Preconditioning

    PubMed Central

    Cocking, Scott; Cable, N. T.; Wilson, Mathew G.; Green, Daniel J.; Thijssen, Dick H. J.; Jones, Helen

    2018-01-01

    Introduction: The ability of ischemic preconditioning (IPC) to enhance exercise capacity may be mediated through altering exercise-induced blood flow and/or vascular function. This study investigated the hypothesis that (local) IPC enhances exercise-induced blood flow responses and prevents decreases in vascular function following exercise. Methods: Eighteen healthy, recreationally trained, male participants (mean ±SD: age 32 ± 8 years; BMI 24.2 ± 2.3; blood pressure 122 ± 10/72 ± 8 mmHg; resting HR 58 ± 9 beats min-1) received IPC (220 mmHg; 4 × 5-min bilateral arms), REMOTE IPC (220 mmHg; 4 × 5-min bilateral legs), or SHAM (20 mmHg; 4 × 5-min bilateral arms) in a counterbalanced order prior to 30-min of submaximal (25% maximal voluntary contraction) unilateral rhythmic handgrip exercise. Brachial artery diameter and blood flow were assessed every 5-min throughout the 30-min submaximal exercise using high resolution ultrasonography. Pre- and post-exercise vascular function was measured using flow-mediated dilation (FMD). Results: IPC resulted in enlarged brachial artery diameter during exercise [0.016 cm (0.003–0.03 cm), P = 0.015] compared to REMOTE IPC, but blood flow during exercise was similar between conditions (P > 0.05). Blood flow (l/min) increased throughout exercise (time: P < 0.005), but there was no main effect of condition (P = 0.29) or condition ∗ time interaction (P = 0.83). Post-exercise FMD was similar between conditions (P > 0.05). Conclusion: Our data show that local (but not remote) IPC, performed as a strategy prior to exercise, enhanced exercise-induced conduit artery diameter dilation, but these changes do not translate into increased blood flow during exercise nor impact post-exercise vascular function. PMID:29740345

  18. [The sural medial perforator flap: Anatomical bases, surgical technique and indications in head and neck reconstruction].

    PubMed

    Struk, S; Schaff, J-B; Qassemyar, Q

    2018-04-01

    The medial sural artery perforator (MSAP) flap is defined as a thin cutaneo-adipose perforator flap harvested on the medial aspect of the leg. The aims of this study were to describe the anatomical basis as well as the surgical technique and discuss the indications in head and neck reconstructive surgery. We harvested 10 MSAP flap on 5 fresh cadavers. For each case, the number and the location of the perforators were recorded. For each flap, the length of pedicle, the diameter of source vessels and the thickness of the flap were studied. Finally, we performed a clinical application of a MSAP flap. A total of 23 perforators with a diameter superior than 1mm were dissected on 10 legs. The medial sural artery provided between 1 and 4 musculocutaneous perforators. Perforators were located in average at 10.3cm±2cm from the popliteal fossa and at 3.6cm±1cm from the median line of the calf. The mean pedicle length was 12.1cm±2.5cm. At its origin, the source artery diameter was 1.8mm±0.25mm and source veins diameters were 2.45mm±0.9mm in average. There was no complication in our clinical application. This study confirms the reliability of previous anatomical descriptions of the medial sural artery perforator flap. This flap was reported as thin and particularly adapted for oral cavity reconstruction and for facial or limb resurfacing. Sequelae might be reduced as compared to those of the radial forearm flap with comparable results. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. Single-Center Experience and 1-Year Follow-up Results of 'Sandwich Technique' in the Management of Common Iliac Artery Aneurysms During EVAR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ricci, Carmelo; Ceccherini, Claudio, E-mail: claudiocec@hotmail.it; Cini, Marco

    Purpose: Abdominal aortic aneurysm (AAA) accompanied by common iliac artery (CIA) aneurysms requires a more demanding procedure owing to the difficulties in obtaining an adequate distal landing zone for the stent-graft limb(s), a potential site of endoleak. The 'sandwich technique' is a procedure to increase EVAR feasibility in the setting of adverse or challenging CIA anatomy. Its main advantages include no restrictions in terms of CIA diameter or length or internal iliac artery (IIA) diameter, no need to wait for a specific stent-graft. Our purpose is to describe our single-center experience and one year follow-up results of this new procedure.more » Materials and Methods: From April 2009 to June 2010, the sandwich technique was performed in our institution in 7 patients treated for AAA and unilateral CIA aneurysms (n. 5) or bilateral CIA aneurysms (n. 2). Inclusion criteria were the presence of unilateral or bilateral CIA aneurysm (independently from its diameter), IIA artery measuring up to 9 mm in its maximum diameter, not dilatation of IIA and EIA. Results: The mean follow-up length was 15 months (range: 14-20 months). All stent-implanted iliac branches remained patent on 1 year follow-up and IIA flow was preserved. None of the patients had symptoms of pelvic ischemia. CT scan follow-up showed aneurysm shrinkage in five patients, without any sign of endoleaks in all cases. Conclusions: In selected cases, the 'sandwich technique' showed good outcomes confirming to be a safe and easy to perform way to overcome anatomical constraints and expanding the limits of EVAR.« less

  20. Validity of the frontolateral approach as a minimally invasive corridor for olfactory groove meningiomas.

    PubMed

    El-Bahy, Khaled

    2009-10-01

    Several approaches are described for olfactory groove meningiomas (OGMs) varying from a very wide bifrontal craniotomy to minimally invasive endoscopic techniques. The goal of this study was to evaluate the results of the frontolateral approach for olfactory groove meningioma. Pitfalls related to this corridor will be described. The impact of tumor size and encasement of the anterior cerebral artery complex on the degree of tumor removal will be described on the basis of experience with 18 cases. Eighteen patients with OGM underwent microsurgical removal using the frontolateral approach. A retrospective study was conducted by analyzing clinical data, neuroimaging studies, operative findings, clinical outcome, and degree of tumor removal. The patients were classified into group A with tumor size less than 4 cm in diameter (7 out of 18 cases, 38.9%) and group B with tumor size more than 4 cm in diameter (11 out of 18 cases, 61.1%). CSF rhinorrhea was observed in three patients (16.7%). Postoperative left frontal intracerebral hematoma occurred in one patient (5.6%) belonging to group A. In another patient (5.6%) belonging to group B, marked right frontal lobe swelling was evident after dural opening, which necessitated partial right frontal pole resection. Total tumor removal (Simpson grade 1 and 2) was achieved in 14 out of 18 patients (77.8%), while subtotal removal (Simpson grade 3 and 4) was achieved in 4 patients (22.2%). In the 14 patients in whom total removal was achieved, 7 belonged to group A (all 7 patients of group A with 100% removal), while the remaining 7 patients belonged to group B (7 out of 11 patients, 63.6% removal; one of them had anterior cerebral artery complex encasement). The four patients in whom subtotal removal was achieved belonged to group B; three of them showed anterior cerebral artery complex encasement, and one elderly patient had non-extensive paranasal sinus involvement. One patient (5.6%) in group B died from cerebral infarction after subtotal tumor removal with anterior cerebral artery injury during its dissection from the tumor capsule. The frontolateral approach has the advantages of both the pterional and conventional bifrontal approaches. The frontolateral approach allows quick and minimally invasive access to OGMs less than 4 cm in diameter, and also to tumors more than 4 cm in diameter without encasement of the anterior cerebral artery complex. Tumor size more than 4 cm in diameter and encasement of the anterior cerebral artery complex are limiting factors for the frontolateral approach if radical tumor removal is considered.

  1. Construction and test of new precision drift-tube chambers for the ATLAS muon spectrometer

    NASA Astrophysics Data System (ADS)

    Kroha, H.; Kortner, O.; Schmidt-Sommerfeld, K.; Takasugi, E.

    2017-02-01

    ATLAS muon detector upgrades aim for increased acceptance for muon triggering and precision tracking and for improved rate capability of the muon chambers in the high-background regions of the detector with increasing LHC luminosity. The small-diameter Muon Drift Tube (sMDT) chambers have been developed for these purposes. With half of the drift-tube diameter of the MDT chambers and otherwise unchanged operating parameters, sMDT chambers share the advantages of the MDTs, but have an order of magnitude higher rate capability and can be installed in detector regions where MDT chambers do not fit in. The chamber assembly methods have been optimized for mass production, minimizing construction time and personnel. Sense wire positioning accuracies of 5 μm have been achieved in serial production for large-size chambers comprising several hundred drift tubes. The construction of new sMDT chambers for installation in the 2016/17 winter shutdown of the LHC and the design of sMDT chambers in combination with new RPC trigger chambers for replacement of the inner layer of the barrel muon spectrometer are in progress.

  2. Predictors of Reintervention After Endovascular Repair of Isolated Iliac Artery Aneurysm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zayed, Hany A., E-mail: hany.zayed@gstt.nhs.uk; Attia, Rizwan; Modarai, Bijan

    2011-02-15

    The objective of this study was to identify factors predicting the need for reintervention after endovascular repair of isolated iliac artery aneurysm (IIAA). We reviewed prospectively collected database records of all patients who underwent endovascular repair of IIAA between 1999 and 2008. Detailed assessment of the aneurysms was performed using computed tomography angiography (CTA). Follow-up protocol included CTA at 3 months. If this showed no complication, then annual duplex scan was arranged. Multivariate analysis and analysis of patient survival and freedom from reintervention were performed using Kaplan-Meier life tables. Forty IIAAs (median diameter 44 mm) in 38 patients were treatedmore » (all men; median age 75 years), and median follow-up was 27 months. Endovascular repair of IIAA was required in 14 of 40 aneurysms (35%). The rate of type I endoleak was significantly higher with proximal landing zone (PLZ) diameter >30 mm in the aorta or >24 mm in the common iliac artery or distal landing zone (DLZ) diameter >24 mm (P = 0.03, 0.03, and 0.0014, respectively). Reintervention rate (RR) increased significantly with increased diameter or decreased length of PLZ; increased DLZ diameter; and endovascular IIAA repair (P = 0.005, 0.005, 0.02, and 0.02 respectively); however, RR was not significantly affected by length of PLZ or DLZ. Freedom-from-reintervention was 97, 93, and 86% at 12, 24, and 108 months. There was no in-hospital or aneurysm-related mortality. Endovascular IIAA repair is a safe treatment option. Proper patient selection is essential to decrease the RR.« less

  3. Cerebral blood velocity and other cardiovascular responses to 2 days of head-down tilt

    NASA Technical Reports Server (NTRS)

    Frey, Mary A. B.; Mader, Thomas H.; Bagian, James P.; Charles, John B.; Meehan, Richard T.

    1993-01-01

    Spaceflight induces a cephalad redistribution of fluid volume and blood flow within the human body, and space motion sickness, which is a problem during the first few days of space flight, could be related to these changes in fluid status and in blood flow of the cerebrum and vestibular system. To evaluate possible changes in cerebral blood flow during simulated weightlessness, we measured blood velocity in the middle cerebral artery (MCA) along with retinal vascular diameters, intraocular pressure, impedance cardiography, and sphygmomanometry on nine men (26.2 +/- 6.6 yr) morning and evening for 2 days during continuous 10 deg head-down tilt (HDT). When subjects went from seated to head-down bed rest, their heart rate and retinal diameters decreased, and intraocular pressures increased. After 48 h of HDT, blood flow velocity in the MCA was decreased and thoracic impedance was increased, indicating less fluid in the thorax. Percent changes in blood flow velocities in the MCA after 48 h of HDT were inversely correlated with percent changes in retinal vascular diameters. Blood flow velocities in the MCA were inversely correlated (intersubject) with arterial pressures and retinal vascular diameters. Heart rate, stroke volume, cardiac output, systolic arterial pressure, and at times pulse pressure and blood flow velocities in the MCA were greater in the evening. Total peripheral resistance was higher in the morning. Although cerebral blood velocity is reduced after subjects are head down for 2 days, the inverse relationship with retinal vessel diameters, which have control analogous to that of cerebral vessels, indicates cerebral blood flow is not reduced.

  4. Underwater noise from geotechnical drilling and standard penetration testing.

    PubMed

    Erbe, Christine; McPherson, Craig

    2017-09-01

    Geotechnical site investigations prior to marine construction typically involve shallow, small-core drilling and standard penetration testing (SPT), during which a small tube is hammered into the ground at the bottom of the borehole. Drilling (120 kW, 83 mm diameter drillbit, 1500 rpm, 16-17 m drill depth in sand and mudstone) and SPT (50 mm diameter test tube, 15 mm wall thickness, 100 kg hammer, 1 m drop height) by a jack-up rig in 7-13 m of water were recorded with a drifting hydrophone at 10-50 m range. Source levels were 142-145 dB re 1 μPa rms @ 1 m (30-2000 Hz) for drilling and 151-160 dB re 1 μPa 2 s @ 1 m (20-24 000 Hz) for SPT.

  5. CT measurement of central pulmonary arteries to diagnose pulmonary hypertension (PHTN): more reliable than valid?

    PubMed

    Terpenning, Silanath; Deng, Matthew; Hong-Zohlman, Susie N; Lin, Cheng Ting; Kligerman, Seth J; Jeudy, Jean; Ketai, Loren H

    2016-01-01

    The association between main pulmonary artery (MPA) size and pulmonary arterial hypertension (PAHTN) is well established; however, the clinical utility of routine measurement of MPA is uncertain due to considerable overlap between normal patients and those with pulmonary hypertension. The lack of diagnostic accuracy could be further degraded by variability among the radiologists. It is unknown whether the addition of right and left pulmonary artery measurements would improve accuracy or further impair it. The purposes of this study are to verify the accuracy of a proposed cutoff value for the size of MPA in the diagnosis PAHTN, to determine the interrater agreement for this measurement, and to determine whether addition of right pulmonary artery (RPA) and left pulmonary artery (LPA) measurement or simple assessment of patient comorbidities can improve the accuracy. Patients undergoing both cardiac catheterization and chest computed tomography (CT) within 3 months of each other at a large university hospital between January 2010 and December 2012 were identified. Patients with prior cardiac surgery or congenital heart disease and critically ill patients were excluded from the study population. Patients with pericardial disease or severe lung disease documented on CT examinations were also excluded. From the remaining patients, 45 patients with normal pulmonary artery pressure and 50 patients with proven pulmonary hypertension were selected. Demographic data and clinical information was collected from medical records of these patients. Three radiologists with different years of experience in cardiothoracic imaging measured the MPA, RPA, and LPA diameters on axial images using an electronic ruler on 3D work stations independently and were masked to the patient clinical symptoms, diagnosis, and each other's measurement to prevent bias. Association between MPA diameter (MPAD) and patient characteristics assessed by one-way analysis of variance for scalar measures. Each reader's measurements were used to construct a separate receiver operating curve (ROC) to assess optimal MPA threshold. The ability of an MPA measurement threshold to correctly identify PAHTN was assessed using chi-squared. Chi-squared was also used to assess the effect of categorical comorbidities on false positive diagnosis. None of the demographic data or patients' factors (age, gender, height, weight, body surface area, and body mass index) were related to the size of MPAD. The distribution of the MPAD was normal in both groups. Based on prior literature, MPAD (≥3.15cm) was selected as the cutoff value to diagnose PAHTN. Review of ROCs did not suggest a superior cutoff value for any reader. Using this threshold per case interrater agreement was good, kappa values >0.65. Based on an average measurement for all three readers, MPAD was 82% sensitive and 62% specific for PAHTN. Limiting positive diagnosis to those subjects with both MPAD ≥3.15 and either enlarged RPA diameter (RPAD) or LPAD diminished sensitivity but did not improve specificity. Defining positive study as the presence of any dilated artery (MPAD, RPAD, or LPAD) increased sensitivity to 94% but decreased specificity to 27%. Comorbidities that might cause fluctuating mean pulmonary artery pressures could not be shown to account for false positive studies. The 29 true negative patients and 16 false positive patients did not differ in the prevalence of obstructive sleep apnea/home oxygen use or documented congestive heart failure/low ejection fraction. Previously proposed threshold of MPAD ≥3.15cm is likely optimal but is not specific for identifying patient with PAHTN. Interobserver differences in MPAD measurement do not account this inaccuracy. Incorporation or RPA and LPA measurement does not improve diagnostic accuracy of PAHTN, and assessment of comorbidities does not easily identify likely false positive cases. Diagnosis of PAHTN based solely on CT examinations of the chest may not be sufficiently accurate for clinical use. Published by Elsevier Inc.

  6. Genetic predisposition scores associate with muscular strength, size, and trainability.

    PubMed

    Thomaes, Tom; Thomis, Martine; Onkelinx, Steven; Goetschalckx, Kaatje; Fagard, Robert; Lambrechts, Diether; Vanhees, Luc

    2013-08-01

    The number of studies trying to identify genetic sequence variation related to muscular phenotypes has increased enormously. The aim of this study was to identify the role of a genetic predisposition score (GPS) based on earlier identified gene variants for different muscular endophenotypes to explain the individual differences in muscular fitness characteristics and the response to training in patients with coronary artery disease. Two hundred and sixty coronary artery disease patients followed a standard ambulatory, 3-month supervised training program for cardiac patients. Maximal knee extension strength (KES) and rectus femoris diameter were measured at baseline and after rehabilitation. Sixty-five single nucleotide polymorphisms (SNP) in 30 genes were selected based on genotype-phenotype association literature. Backward regression analysis revealed subsets of SNP associated with the different phenotypes. GPS were constructed for all sets of SNP by adding up the strength-increasing alleles. General linear models and multiple stepwise regression analysis were used to test the explained variance of the GPS in baseline and strength responses. Receiver operating characteristic curve analyses were performed to discriminate between high- and low-responder status. GPS were significantly associated with the rectus femoris diameter (P < 0.01) and its response (P < 0.0001), the isometric KES (P < 0.05) and its response (P < 0.01), the isokinetic KES at 60° · s (P < 0.05) and 180° · s (P < 0.001) and their responses to training (P < 0.0001), and the isokinetic KES endurance (P < 0.001) and its change after training (P < 0.0001). The GPS was shown as an independent determinant in baseline and response phenotypes with partial explained variance up to 23%. Receiver operating characteristic analysis showed a significant discriminating accuracy of the models, including the GPS for responses to training, with areas under the curve ranging from 0.62 to 0.85. GPS for muscular phenotypes showed to be associated with baseline KES, muscle diameter, and the response to training in cardiac rehabilitation patients.

  7. A balloon-expandable sheath facilitates transfemoral TAVR in patients with peripheral vascular disease and tortuosity.

    PubMed

    Goldsweig, Andrew M; Faheem, Osman; Cleman, Michael W; Forrest, John K

    2015-06-01

    We sought to perform transcatheter aortic valve replacement (TAVR) via the transfemoral approach in patients with peripheral arterial disease (PAD), small caliber ileofemoral vessels and vascular tortuosity. For patients with increased surgical risk, TAVR is associated with a higher 1-year survival rate than surgical aortic valve replacement (SAVR). Transfemoral vascular access for TAVR results in superior outcomes versus procedures performed via other routes in terms of mortality, morbidity and healthcare economics. In many patients, the ability to safely perform the procedure via the transfemoral approach is limited by narrow, diseased and tortuous ileofemoral vasculature. We employed the SoloPath Balloon Expandable TransFemoral Access System (Terumo Med. Corp., Tokyo, Japan) to perform transfemoral TAVR in five patients with PAD, small caliber ileofemoral vessels and vascular tortuosity. We report our experience using this balloon-expandable sheath during 5 cases of transfemoral TAVR in patients with inhospitable ileofemoral vasculature of mean diameter ⩽ 5.8 mm. The unexpanded sheath's malleable structure and hydrophilic coating permitted deployment despite severe stenoses and tortuosity. Subsequent inflation to 18 Fr facilitated successful TAVR. Postprocedural angiography demonstrated no significant vascular access complications. In one case, the entire procedure was performed percutaneously, without common femoral artery surgical cutdown. The SoloPath sheath system permits transfemoral TAVR in patients with PAD small caliber ileofemoral vessels and vascular tortuosity. The transfemoral balloon-expandable sheath allowed these patients to avoid the increased morbidity and mortality risks associated with direct aortic or transapical access. © The Author(s), 2015.

  8. Changes in cardiac contractility during graded exercise are greater in subjects with smaller body mass index, and greater in men than women: analyses using wave intensity and force-frequency relations.

    PubMed

    Tanaka, Midori; Sugawara, Motoaki; Niki, Kiyomi; Ogasawara, Yasuo

    2018-06-15

    Estimation of the contractility of the left ventricle during exercise is an important part of the rehabilitation protocol. It is known that cardiac contractility increases with an increase in heart rate. This phenomenon is called the force-frequency relation (FFR). Using wave intensity, we aimed to evaluate FFR noninvasively during graded exercise. We enrolled 83 healthy subjects. Using ultrasonic diagnostic equipment, we measured wave intensity (WD), which was defined in terms of blood velocity and arterial diameter, in the carotid artery and heart rate (HR) before and during bicycle ergometer exercise. FFRs were constructed by plotting the maximum value of WD (WD 1 ) against HR. We analyzed the variation among FFR responses of individual subjects. WD 1 increased linearly with an increase in HR during exercise. The average slope of the FFR was 1.0 ± 0.5 m/s 3  bpm. The slope of FFR decreased with an increase in body mass index (BMI). The slopes of FFRs were steeper in men than women, although there were no differences in BMI between men and women. The FFR was obtained noninvasively by carotid arterial wave intensity (WD 1 ) and graded exercise. The slope of the FFR decreased with an increase in BMI, and was steeper in men than women.

  9. Data on a single oral dose of camu camu (Myrciaria dubia) pericarp extract on flow-mediated vasodilation and blood pressure in young adult humans.

    PubMed

    Miyashita, Tadayoshi; Koizumi, Ryosuke; Myoda, Takao; Sagane, Yoshimasa; Niwa, Koichi; Watanabe, Toshihiro; Minami, Kazuhiro

    2018-02-01

    This data article describes the flow-mediated vasodilation (FMD) responses, represented by changes in arterial diameter, and blood pressure changes in young adults after a single oral dose of camu camu ( Myrciaria dubia ) pericarp extract or placebo (cross-over design). Ten healthy men and 10 healthy women participated in this study. Ultrasonic diagnostic equipment was used to monitor arterial diameter changes, indicative of FMD, for 110 s after the administration of the camu camu extract or placebo. In addition, the systolic and diastolic blood pressure values were recorded.

  10. Ultrasonography of umbilical structures in clinically normal foals.

    PubMed

    Reef, V B; Collatos, C

    1988-12-01

    The umbilical arteries, urachus, and umbilical vein were scanned ultrasonographically in 13 clinically normal foals that ranged in age from 6 hours to 4 weeks. Sonograms were obtained using a 7.5-MHz sector scanner transducer placed across the midline of the ventral portion of the foal's abdominal wall. The umbilical vein was scanned from the umbilical stalk to its entrance into the hepatic parenchyma. The mean (+/- SD) diameter of the umbilical vein was 0.61 +/- 0.20 cm immediately cranial to the umbilical stalk, 0.52 +/- 0.19 cm midway between the umbilicus and liver, and 0.6 +/- 0.19 cm at the liver. The urachus and umbilical arteries were scanned from the umbilical stalk to the apex of the urinary bladder and had a mean total diameter of 1.75 +/- 0.37 cm at the bladder apex. The umbilical arteries also were scanned along either side of the bladder and had a mean diameter of 0.85 +/- 0.21 cm. These measurements and the ultrasonographic appearance of the internal umbilical structures from clinically normal foals can be used as references to diagnose abnormalities of the umbilical structures in neonatal foals.

  11. Modeling process of embolization arteriovenous malformation on the basis of two-phase filtration model

    NASA Astrophysics Data System (ADS)

    Cherevko, A. A.; Gologush, T. S.; Ostapenko, V. V.; Petrenko, I. A.; Chupakhin, A. P.

    2016-06-01

    Arteriovenous malformation is a chaotic disordered interlacement of very small diameter vessels, performing reset of blood from the artery into the vein. In this regard it can be adequately modeled using porous medium. In this model process of embolization described as penetration of non-adhesive substance ONYX into the porous medium, filled with blood, both of these fluids are not mixed with each other. In one-dimensional approximation such processes are well described by Buckley-Leverett equation. In this paper Buckley-Leverett equation is solved numerically by using a new modification of Cabaret scheme. The results of numerical modeling process of embolization of AVM are shown.

  12. Anatomic Basis for Penis Transplantation: Cadaveric Microdissection of Penile Structures.

    PubMed

    Tiftikcioglu, Yigit Ozer; Erenoglu, Cagil Meric; Lineaweaver, William C; Bilge, Okan; Celik, Servet; Ozek, Cuneyt

    2016-06-01

    We present a cadaveric dissection study to investigate the anatomic feasibility of penile transplantation. Seventeen male cadavers were dissected to reveal detailed anatomy of the dorsal neurovascular structures including dorsal arteries, superficial and deep dorsal veins, and dorsal nerves of the penis. Dorsal artery diameters showed a significant decrease from proximal to distal shaft. Dominance was observed in one side. Deep dorsal vein showed a straight course and less decrease in diameter compared to artery. Dorsal nerves showed proximal branching pattern. In a possible penile transplantation, level of harvest should be determined according to the patient and the defect, where a transgender patient will receive a total allograft and a male patient with a proximal penile defect will receive a partial shaft allograft. We designed an algorithm for different levels of penile defect and described the technique for harvest of partial and total penile transplants.

  13. Anatomic Patterns of Renal Arterial Sympathetic Innervation: New Aspects for Renal Denervation.

    PubMed

    Imnadze, Guram; Balzer, Stefan; Meyer, Baerbel; Neumann, Joerg; Krech, Rainer Horst; Thale, Joachim; Franz, Norbert; Warnecke, Henning; Awad, Khaled; Hayek, Salim S; Devireddy, Chandan

    2016-12-01

    Initial studies of catheter-based renal arterial sympathetic denervation to lower blood pressure in resistant hypertensive patients renewed interest in the sympathetic nervous system's role in the pathogenesis of hypertension. However, the SYMPLICITY HTN-3 study failed to meet its prespecified blood pressure lowering efficacy endpoint. To date, only a limited number of studies have described the microanatomy of renal nerves, of which, only two involve humans. Renal arteries were harvested from 15 cadavers from the Klinikum Osnabruck and Schuchtermann Klinik, Bad Rothenfelde. Each artery was divided longitudinally in equal thirds (proximal, middle, and distal), with each section then divided into equal superior, inferior, anterior, and posterior quadrants, which were then stained. Segments containing no renal nerves were given a score value = 0, 1-2 nerves with diameter <300 µm a score = 1; 3-4 nerves or nerve diameter 300-599 µm a score = 2, and >4 nerves or nerve diameter ≥600 µm a score = 3. A total of 22 renal arteries (9 right-sided, 13 left-sided) were suitable for examination. Overall, 691 sections of 5 mm thickness were prepared. Right renal arteries had significantly higher mean innervation grade (1.56 ± 0.85) compared to left renal arteries (1.09 ± 0.87) (P < 0.001). Medial (1.30 ± 0.59) and distal (1.39 ± 0.62) innervation was higher than the proximal (1.17 ± 0.55) segments (p < 0.001). When divided in quadrants, the anterior (1.52 ± 0.96) and superior (1.71 ± 0.89) segments were more innervated compared to posterior (0.96 ± 0.72) and inferior (0.90 ± 0.68) segments (P < 0.001). That the right renal artery has significantly higher innervation scores than the left. The anterior and superior quadrants of the renal arteries scored higher in innervation than the posterior and inferior quadrants did. The distal third of the renal arteries are more innervated than the more proximal segments. These findings warrant further evaluation of the spatial innervation patterns of the renal artery in order to understand how it may enhance catheter-based renal arterial denervation procedural strategy and outcomes. The SYMPLICITY HTN-3 study dealt a blow to the idea of the catheter-based renal arterial sympathetic denervation. We investigated the location and patterns of periarterial renal nerves in cadaveric human renal arteries. To quantify the density of the renal nerves we created a novel innervation score. On average the right renal arteries were significantly more densely innervated than the left renal arteries, the anterior and superior segments were significantly more innervated compared to the posterior and inferior segments, absolute innervation scores in the proximal third of the left or right renal arteries were always lower when compared to distal segments. These findings may enhance catheter-based renal arterial denervation procedural strategy and outcomes. © 2016, Wiley Periodicals, Inc.

  14. Time-resolved PIV measurements of the flow field in a stenosed, compliant arterial model

    NASA Astrophysics Data System (ADS)

    Geoghegan, P. H.; Buchmann, N. A.; Soria, J.; Jermy, M. C.

    2013-05-01

    Compliant (flexible) structures play an important role in several biological flows including the lungs, heart and arteries. Coronary heart disease is caused by a constriction in the artery due to a build-up of atherosclerotic plaque. This plaque is also of major concern in the carotid artery which supplies blood to the brain. Blood flow within these arteries is strongly influenced by the movement of the wall. To study these problems experimentally in vitro, especially using flow visualisation techniques, can be expensive due to the high-intensity and high-repetition rate light sources required. In this work, time-resolved particle image velocimetry using a relatively low-cost light-emitting diode illumination system was applied to the study of a compliant flow phantom representing a stenosed (constricted) carotid artery experiencing a physiologically realistic flow wave. Dynamic similarity between in vivo and in vitro conditions was ensured in phantom construction by matching the distensibility and the elastic wave propagation wavelength and in the fluid system through matching Reynolds ( Re) and Womersley number ( α) with a maximum, minimum and mean Re of 939, 379 and 632, respectively, and a α of 4.54. The stenosis had a symmetric constriction of 50 % by diameter (75 % by area). Once the flow rate reached a critical value, Kelvin-Helmholtz instabilities were observed to occur in the shear layer between the main jet exiting the stenosis and a reverse flow region that occurred at a radial distance of 0.34 D from the axis of symmetry in the region on interest 0-2.5 D longitudinally downstream from the stenosis exit. The instability had an axis-symmetric nature, but as peak flow rate was approached this symmetry breaks down producing instability in the flow field. The characteristics of the vortex train were sensitive not only to the instantaneous flow rate, but also to whether the flow was accelerating or decelerating globally.

  15. Sirolimus- versus paclitaxel-eluting stents in patients with stenosis in a native coronary artery.

    PubMed

    Doggrell, Sheila A

    2004-06-01

    With stenting, restenosis occurs in approximately 25% of patients and the incidence is even higher in patients with diabetes, small coronary vessels and long lesions. The sirolimus-eluting balloon-expandable stent in the treatment of patients with de novo native coronary-artery lesions (SIRIUS) trial, enrolled patients with more challenging conditions, including a higher frequency of diabetes, more complex lesion morphology and longer lesions and showed benefits in all groups. After 240 days, the frequency of stenosis of at least 50% of the luminal diameter was 3.2 and 35.4% in the sirolimus and standard stents groups, respectively. The TAXUS-IV trial was the first large-scale trial on the safety and efficacy of paclitaxel-eluting stents in a broad population of patients and lesions, and established the safety and effectiveness of this agent. After 9 months, there was a mean stenosis of 17% in the paclitaxel group compared to 37% of patients treated with a bare stent. Thus, the local delivery of potent cell cycle inhibitors (sirolimus, paclitaxel) from stents being used for revascularisation dramatically decreases the incidence of restenosis in the populations of patients studied so far and represents a major advancement in the treatment of coronary artery disease.

  16. Anatomic Suitability for Transcaval Access Based on Computed Tomography.

    PubMed

    Lederman, Robert J; Greenbaum, Adam B; Rogers, Toby; Khan, Jaffar M; Fusari, Melissa; Chen, Marcus Y

    2017-01-09

    Transcaval access has been used successfully for over 200 transcatheter aortic valve replacements, large-bore percutaneous left ventricular assist devices, and thoracic endovascular aortic aneurysm repairs. This review teaches how to plan transcaval access and closure based on computed tomography. The main planning goals are to: 1) identify calcium-free crossing targets in the abdominal aorta along with optimal fluoroscopic projection angles and level with respect to lumbar vertebrae; 2) identify obstacles such as interposed bowel or pedunculated aortic atheroma; 3) plan covered stent bailout; and 4) identify jeopardized vascular branches such as renal arteries that might be obstructed by bailout covered stents if employed. The aorta and inferior vena cava are segmented (sculpted) using an image reconstruction workstation and crossing targets are highlighted. Important measurements such as aortic lumen diameter and target distance from renal arteries, aortoiliac bifurcation, and right femoral vein puncture site are reported to assist the operator. The proposed classification for transcaval feasibility has been revised, making some previously unfavorable candidates now feasible or favorable based on procedural success to date. Transcaval access allows percutaneous introduction of large devices into the aorta despite small or diseased iliofemoral arteries. By following these simplified procedures, both operators and imaging specialists can easily prepare comprehensive treatment plans. Copyright © 2017 American College of Cardiology Foundation. All rights reserved.

  17. Porous Gelatin Particles for Uterine Artery Embolization: An Experimental Study of Intra-Arterial Distribution, Uterine Necrosis, and Inflammation in a Porcine Model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sone, Miyuki, E-mail: msone@athena.ocn.ne.j; Osuga, Keigo; Shimazu, Kohki

    PurposeWe evaluated the location of porous gelatin particles (GP; Gelpart; Nippon Kayaku/Astellas, Tokyo, Japan) within the arterial vasculature and their acute effects on uterine necrosis and inflammation after uterine artery embolization (UAE) in swine.Materials and MethodsAdult nonpregnant pigs (n = 6) were allocated to either 1- (n = 3) or 2-mm GP (n = 3). Superselective and bilateral embolization of the uterine arteries was performed. All animals were killed 1 week after UAE. Macroscopic and microscopic findings, including the level of arterial occlusion and their effect on uterine necrosis and inflammation, were analyzed.ResultsAll UAE procedures were completed without severe complications.more » The macroscopic necrosis was seen in two animals in the 2-mm group with an extent of <50%. The location of the occluded arteries did not differ significantly between groups. The median diameters of the occluded arteries were 449 {mu}m (95% confidence interval [CI] 417-538 {mu}m) in the 1-mm GP group and 484 {mu}m (95% CI 370-560 {mu}m) in the 2-mm GP group. As for microscopic necrosis, no statistically significant difference was observed. The qualitative inflammatory reaction was significantly greater in the 2-mm GP group than in the 1-mm group (p < 0.001).ConclusionsBoth 1- and 2-mm GP occluded the arteries relevant to the target diameter for UAE in porcine uterus, presumably due to the plastic deformity. Both sizes of GP were associated with limited areas of necrosis; however, evaluation of inflammatory reaction was preliminary. Further study with adequate evaluation of inflammatory reactions is suggested.« less

  18. Numerical simulation of blood flow in femoral perfusion: comparison between side-armed femoral artery perfusion and direct femoral artery perfusion.

    PubMed

    Kitamura, Shingo; Shirota, Minori; Fukuda, Wakako; Inamura, Takao; Fukuda, Ikuo

    2016-12-01

    Computational numerical analysis was performed to elucidate the flow dynamics of femoral artery perfusion. Numerical simulation of blood flow was performed from the right femoral artery in an aortic model. An incompressible Navier-Stokes equation and continuity equation were solved using computed flow dynamics software. Three different perfusion models were analyzed: a 4.0-mm cannula (outer diameter 15 French size), a 5.2-mm cannula (18 French size) and an 8-mm prosthetic graft. The cannula was inserted parallel to the femoral artery, while the graft was anastomosed perpendicular to the femoral artery. Shear stress was highest with the 4-mm cannula (172 Pa) followed by the graft (127 Pa) and the 5.2-mm cannula (99 Pa). The cannula exit velocity was high, even when the 5.2-mm cannula was used. Although side-armed perfusion with an 8-mm graft generated a high shear stress area near the point of anastomosis, flow velocity at the external iliac artery was decreased. The jet speed decreased due to the Coanda effect caused by the recirculation behind sudden expansion of diameter, and the flow velocity maintains a constant speed after the reattachment length of the flow. This study showed that iliac artery shear stress was lower with the 5.2-mm cannula than with the 4-mm cannula when used for femoral perfusion. Side-armed graft perfusion generates a high shear stress area around the anastomotic site, but flow velocity in the iliac artery is slower in the graft model than in the 5.2-mm cannula model.

  19. A model of hydraulic interactions in liver parenchyma as forces behind the intrahepatic bile flow.

    PubMed

    Kurbel, S; Kurbel, B; Dmitrovic, B; Wagner, J

    2001-05-01

    The small diameters of bile canaliculi and interlobular bile ducts make it hard to attribute the bile flow solely to the process of secretion. In the model liver within its capsule is considered a limited space in which volume expansions of one part are possible only through the shrinking of other parts. The liver capsule allows only very slow volume changes. The rate of blood flow through the sinusoides is governed by the Poisseuill-Hagen law. The model is based on a concept of circulatory liver units. A unit would contain a group of acini sharing the same conditions of arterial flow. We can imagine them as an acinar group behind the last pressure reducer on one arterial branch. Acini from neighboring units compose liver lobules and drain through the same central venule. One lobule can contain acini from several neighboring circulatory units. The perfusion cycle in one unit begins with a transient tide in the arterial flow, governed by local mediators. Corresponding acini expand, grabbing the space by compressing their neighbors in the same lobules. Vascular resistance is reduced in dilated and increased in compressed acini. Portal blood flows through the dilated acini, bypassing the compressed neighbors. The cycle ends when the portal tide slowly diminishes and acinar volume is back on the interphase value until the new perfusion cycle is started in another circulatory unit. Each cycle probably takes minutes to complete. Increased pressures both in dilated and in compressed acini force the bile to move from acinar canalicules. Both up and down changes in acinar volume might force the acinar biliary flow. In cases of arterial vasoconstriction, increased activity of vasoactive substances would keep most of the circulatory units in the interphase and increased liver resistance can be expected. Liver fibrosis makes all acini to be of fixed volume and result in increased resistance. Because of that, low pressure portal flow would be more compromised, as reported. In livers without arterial blood flow, although some slow changes in the portal flows can be expected, acinar volume changes should be reduced. In acute liver injury, enlarged hepatocytes would diminish sinusoidal diameter and increase acinar resistance. In liver tumors, areas of neovascularization with reduced resistance would divert the arterial flow from the normal tissue, while in the compressed perifocal areas, increased vascular resistance should diminish mainly the portal flow. Copyright 2001 Harcourt Publishers Ltd.

  20. The Effects of Losartan in Preserving the Structural Integrity of Decellularized Small Diameter Vascular Allograft Conduit Implants In Vivo.

    PubMed

    Lee, Seung Hyun; Lee, Byoung Wook; Kim, Seong Who; Choo, Suk Jung

    2017-01-01

    Decellularization is a proposed method of preparing nonautologous biological arterial vascular scaffolding; however, the fate of the supporting medial elastic fiber, which is important in preserving the vascular structural integrity, is uncertain. The influence of losartan on preserving the medial elastic fiber integrity in decellularized small diameter vascular conduits (SDVC) was investigated. Decellularized infrarenal abdominal aortic allografts were implanted in Sprague-Dawley rats treated either with (study rats, n = 6) or without oral losartan (control rats, n = 6) and graded 8 weeks later according to a remodeling scoring system (1-mild, 2-moderate, 3-severe) which we devised based on the intimal hyperplasia degree, morphologic changes, and elastic fiber fragmentation of the conduits. DAPI immunohistochemistry analysis was performed in 47 (25 decellularization only and 22 losartan treatment) cross-sectional slide specimens. The losartan versus decellularization only SDVC showed a significantly lower medial elastic fragmentation score (1.32 vs. 2.24, P < 0.001), superior medial layer preservation, and relatively more normal appearing intimal cellular morphology. The results suggested rats receiving decellularized SDVCs treated with losartan may yield superior medial layer elastic fiber preservation. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  1. Diffusive oxygen shunting between vessels in the preglomerular renal vasculature: anatomic observations and computational modeling.

    PubMed

    Gardiner, Bruce S; Thompson, Sarah L; Ngo, Jennifer P; Smith, David W; Abdelkader, Amany; Broughton, Brad R S; Bertram, John F; Evans, Roger G

    2012-09-01

    To understand how geometric factors affect arterial-to-venous (AV) oxygen shunting, a mathematical model of diffusive oxygen transport in the renal cortex was developed. Preglomerular vascular geometry was investigated using light microscopy (providing vein shape, AV separation, and capillary density near arteries) and published micro-computed tomography (CT) data (providing vessel size and AV separation; Nordsletten DA, Blackett S, Bentley MD, Ritman EL, Smith NP. IUPS Physiome Project. http://www.physiome.org.nz/publications/nordsletten_blackett_ritman_bentley_smith_2005/folder_contents). A "U-shaped" relationship was observed between the arterial radius and the distance between the arterial and venous lumens. Veins were found to partially wrap around the artery more consistently for larger rather than smaller arteries. Intrarenal arteries were surrounded by an area of fibrous tissue, lacking capillaries, the thickness of which increased from ∼5 μm for the smallest arteries (<16-μm diameter) to ∼20 μm for the largest arteries (>200-μm diameter). Capillary density was greater near smaller arteries than larger arteries. No capillaries were observed between wrapped AV vessel pairs. The computational model comprised a single AV pair in cross section. Geometric parameters critical in renal oxygen transport were altered according to variations observed by CT and light microscopy. Lumen separation and wrapping of the vein around the artery were found to be the critical geometric factors determining the amount of oxygen shunted between AV pairs. AV oxygen shunting increases both as lumen separation decreases and as the degree of wrapping increases. The model also predicts that capillaries not only deliver oxygen, but can also remove oxygen from the cortical parenchyma close to an AV pair. Thus the presence of oxygen sinks (capillaries or tubules) near arteries would reduce the effectiveness of AV oxygen shunting. Collectively, these data suggest that AV oxygen shunting would be favored in larger vessels common to the cortical and medullary circulations (i.e., arcuate and proximal interlobular arteries) rather than the smaller vessels specific to the cortical circulation (distal interlobular arteries and afferent arterioles).

  2. Measurement of Flow-Mediated Dilation of Mouse Femoral Artery in vivo by Optical Coherence Tomography.

    PubMed

    Song, Weiye; Zhou, Libo; Kot, Kevin Liu; Fan, Huijie; Han, Jingyan; Yi, Ji

    2018-05-31

    Flow-mediated vasodilation (FMD) is used for assessment of vascular endothelial function in humans as a predictor of cardiovascular events. It has been challenging to carry it on preclinical murine models due to the diminutive size of the femoral artery. Here, we present a new approach to accurately measure the blood velocity and femoral artery diameters of mice by acquiring Doppler optical coherence tomography (DOCT) and optical coherence tomography angiography (OCTA) continuously within one single experimental scanning protocol. Using the high precision three-dimensional imaging and new velocity algorithm, the measurement precision of diameter, blood flow, velocity, and wall shear stress are improved to 0.91%, 11.0%, 10.7%, and 14.0%, respectively. FMD of healthy mouse femoral artery measured by this method was 11.96 ± 0.98%, which was blunted to 5.69±0.4% by intravenous administration of eNOS inhibitor (L-NAME), in agreement with that reported in the literature. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  3. Antioxidant pretreatment and reduced arterial endothelial dysfunction after diving.

    PubMed

    Obad, Ante; Valic, Zoran; Palada, Ivan; Brubakk, Alf O; Modun, Darko; Dujić, Zeljko

    2007-12-01

    We have recently shown that a single air dive leads to acute arterial vasodilation and impairment of endothelium-dependent vasodilatation in humans. Additionally we have found that predive antioxidants at the upper recommended daily allowance partially prevented some of the negative effects of the dive. In this study we prospectively evaluated the effect of long-term antioxidants at a lower RDA dose on arterial endothelial function. Eight professional male divers performed an open sea air dive to 30 msw. Brachial artery flow-mediated dilation (FMD) was assessed before and after diving. The first dive, without antioxidants, caused significant brachial arterial diameter increase from 3.85 +/- 0.55 to 4.04 +/- 0.5 mm and a significant reduction of FMD from 7.6 +/- 2.7 to 2.8 +/- 2.1%. The second dive, with antioxidants, showed unchanged arterial diameter and significant reduction of FMD from 8.11 +/- 2.4 to 6.8 +/- 1.4%. The FMD reduction was significantly less with antioxidants. Vascular smooth muscle function, assessed by nitroglycerine (endothelium-independent dilation), was unaffected by diving. This study shows that long-term antioxidant treatment at a lower RDA dose ending 3-4 h before a dive reduces the endothelial dysfunction in divers. Since the scuba dive was of a similar depth and duration to those practiced by numerous recreational divers, this study raises the possibility of routine predive supplementation with antioxidants.

  4. Effect of fructose and sucralose on flow-mediated vasodilatation in healthy, white European males.

    PubMed

    Memon, Muhammad Qasim; Simpson, Elizabeth Jane; Macdonald, Ian Andrew

    2014-07-01

    To assess how acute consumption of fructose affects flow-mediated dilatation in brachial artery. The randomised cross-over study was conducted at the University of Nottingham's Medical School, Nottingham, United Kingdom in July 2009. Ten healthy, white European males visited the laboratory twice, on separate mornings. On each visit, the volunteers consumed water (3 ml/kg bodyweight) and rested semi-supine on the bed. After 30 minutes, baseline diastolic brachial artery diameter and blood velocity was measured. At 60 minutes, blood velocity and five scans of brachial artery diameter were recorded before a blood pressure cuff was inflated on the forearm for 5 minutes and at 50-60-70-80 and 90 sec after cuff deflation. Fifteen minutes later, the volunteers consumed 500 ml of test-drink containing either fructose (0.75 g/kg bodyweight) or sucralose (sweetness-matched with fructose drink); 45 minutes later, baseline and flow-mediated dilatation was re-measured. Pre-drink and post-drink baseline values were similar on two occasions (p > 0.05). Brachial artery diameter increased (p < 0.05) by 7 +/- 3% pre-fructose and by 6.9 +/- 3% above baseline values post-fructose with no significant difference in these responses (p < 0.15). It increased (p < 0.05) by 5.9 +/- 3% above baseline before and by 6.7 +/- 2% (p < 0.01) after sucralose; a significant difference was noted in these flow-mediated dilatation responses (p < 0.02). Responses before and after sucralose were not different from those before and after fructose (p < 0.294). Acute ingestion of fructose or sucralose had no effect on flow-mediated dilatation measured at brachial artery.

  5. Friction Stir Welding of Line-Pipe Steels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sanderson, Samuel; Mahoney, Murray; Feng, Zhili

    Friction stir welding (FSW) offers both economic and technical advantages over conventional fusion welding practices for welding line-pipe. For offshore line-pipe construction, the economic savings has been shown to be considerable, approaching a calculated 25%. Offshore pipe is relatively small diameter but heavy wall compared to onshore pipe. One concern is the ability to achieve consistent full weld penetration in an on-site offshore FSW operation, e.g., on a lay-barge. In addition, depending on the size and morphology of the unwelded zone, lack of penetration at the weld root can be difficult if not impossible to detect by conventional NDE methods.more » Thus, an approach to assure consistent full penetration via process control is required for offshore line-pipe construction using FSW. For offshore construction, an internal structural mandrel can be used offering the opportunity to use a sacrificial anvil FSW approach. With this approach, a small volume of sacrificial material can be inserted into the structural anvil. The FSW tool penetrates into the sacrificial anvil, beyond the inner diameter of the pipe wall, thus assuring full penetration. The sacrificial material is subsequently removed from the pipe inner wall. In the work presented herein, FSW studies were completed on both 6 mm and 12 mm wall thickness line-pipe. Lastly, post-FSW evaluations including radiography, root-bend tests, and metallography demonstrated the merits of the sacrificial anvil approach to achieve consistent full penetration.« less

  6. Achieving femoral artery hemostasis after cardiac catheterization: a comparison of methods.

    PubMed

    Schickel, S I; Adkisson, P; Miracle, V; Cronin, S N

    1999-11-01

    Cardiac catheterization is a common procedure that involves the introduction of a small sheath (5F-8F) into the femoral artery for insertion of other diagnostic catheters. After cardiac catheterization, local compression of the femoral artery is required to prevent bleeding and to achieve hemostasis. Traditional methods of achieving hemostasis require significant time and close supervision by medical personnel and can contribute to patients' discomfort. VasoSeal is a recently developed device that delivers absorbable collagen into the supra-arterial space to promote hemostasis. To compare outcomes between patients receiving a collagen plug and patients in whom a traditional method of achieving hemostasis was used after diagnostic cardiac catheterization. An outcomes tracking tool was used to analyze the medical records of 95 patients in whom a traditional method was used (traditional group) and 81 patients in whom VasoSeal was used (device group) to achieve hemostasis. Complications at the femoral access site, patients' satisfaction, and times to hemostasis, ambulation, and discharge were compared. Hematomas of 6-cm diameter occurred in 5.3% of the traditional group; no complications occurred in the device group. The device group also achieved hemostasis faster and had earlier ambulation (P < .001). Patients in the device group were discharged a mean of 5 hours sooner than patients in the traditional group (P < .05). No significant differences were found in patients' satisfaction. VasoSeal is a safe and effective method of achieving hemostasis after cardiac catheterization that can hasten time to hemostasis, ambulation, and discharge.

  7. Comparison of the Multidetector-row Computed Tomographic Angiography Axial and Coronal Planes' Usefulness for Detecting Thoracodorsal Artery Perforators

    PubMed Central

    Kim, Jong Gyu

    2012-01-01

    Background During the planning of a thoracodorsal artery perforator (TDAP) free flap, preoperative multidetector-row computed tomographic (MDCT) angiography is valuable for predicting the locations of perforators. However, CT-based perforator mapping of the thoracodorsal artery is not easy because of its small diameter. Thus, we evaluated 1-mm-thick MDCT images in multiple planes to search for reliable perforators accurately. Methods Between July 2010 and October 2011, 19 consecutive patients (13 males, 6 females) who underwent MDCT prior to TDAP free flap operations were enrolled in this study. Patients ranged in age from 10 to 75 years (mean, 39.3 years). MDCT images were acquired at a thickness of 1 mm in the axial, coronal, and sagittal planes. Results The thoracodorsal artery perforators were detected in all 19 cases. The reliable perforators originating from the descending branch were found in 14 cases, of which 6 had transverse branches. The former were well identified in the coronal view, and the latter in the axial view. The location of the most reliable perforators on MDCT images corresponded well with the surgical findings. Conclusions Though MDCT has been widely used in performing the abdominal perforator free flap for detecting reliable perforating vessels, it is not popular in the TDAP free flap. The results of this study suggest that multiple planes of MDCT may increase the probability of detecting the most reliable perforators, along with decreasing the probability of missing available vessels. PMID:22872839

  8. Basilar artery atherosclerotic plaques in paramedian and lacunar pontine infarctions: a high-resolution MRI study.

    PubMed

    Klein, Isabelle F; Lavallée, Philippa C; Mazighi, Mikael; Schouman-Claeys, Elisabeth; Labreuche, Julien; Amarenco, Pierre

    2010-07-01

    Pontine infarction is most often related to basilar artery atherosclerosis when the lesion abuts on the basal surface (paramedian pontine infarction), whereas small medial pontine lesion is usually attributed to small vessel lipohyalinosis. A previous study has found that high-resolution MRI can detect basilar atherosclerotic plaques in up to 70% of patient with paramedian pontine infarction, even in patients with normal angiograms, but none has evaluated the presence of basilar artery plaque by high-resolution MRI in patients with small medial pontine lesion in the medial part of the pons. Consecutive patients with pontine infarction underwent basilar angiography using time-of-flight and contrast-enhanced 3-dimensional MR angiography to assess the presence of basilar artery stenosis and high-resolution MRI to assess the presence of atherosclerotic plaque. Basilar artery angiogram was scored as "normal," "irregular," or "stenosed" >or=30%" and basilar artery by high-resolution MRI was scored as "normal" or "presence of plaque." Medial pontine infarcts were divided into paramedian pontine infarction and small medial pontine lesion groups. Forty-one patients with pontine infarction were included, 26 with paramedian pontine infarction and 15 with small medial pontine lesion. High-resolution MRI detected basilar artery atherosclerosis in 42% of patients with a pontine infarction and normal basilar angiograms. Among patients with paramedian pontine infarction, 65% had normal basilar angiograms but 77% had basilar artery atherosclerosis detected on high-resolution MRI. Among patients with small medial pontine lesion, 46% had normal basilar angiograms but 73% had basilar artery plaques detected on by high-resolution MRI. This study suggests that medial pontine lacunes may be due to a penetrating artery disease secondary to basilar artery atherosclerosis. High-resolution MRI could help precise stroke subtyping.

  9. Multiple sites of vascular dilation or aneurysmal disease and matrix metalloproteinase genetic variants in patients with abdominal aortic aneurysm.

    PubMed

    Fiotti, Nicola; Calvagna, Cristiano; Sgorlon, Giada; Altamura, Nicola; Pitacco, Paola; Zamolo, Francesca; Di Girolamo, Filippo Giorgio; Chiarandini, Stefano; Biolo, Gianni; Adovasio, Roberto

    2018-06-01

    The objective of this study was to assess whether functional genetic polymorphisms of matrix metalloproteinases (MMPs) 1, 3, 9, and 12 are associated with arterial enlargements or aneurysms of the thoracic aorta or popliteal arteries in patients with abdominal aortic aneurysm (AAA). The associations between MMP1 (-1607 G in/del, rs1799750), MMP3 (-1171 A in/del rs35068180), MMP9 (13-26 CA repeats around -90, rs2234681, rs917576, rs917577), and MMP12 (G/T missense variation, rs652438) polymorphisms and enlargements or aneurysms of the thoracic aorta and popliteal arteries were tested in 169 consecutive AAA patients. Thoracic aorta enlargement or aneurysm (TE/A; maximum diameter, >35 mm) was detected in 34 patients (20.1% prevalence). MMP9 rs2234681 microsatellite was the only genetic determinant of TE/A in AAA patients (P = .003), followed by hypercholesterolemia and antiplatelet use. Carriers of both alleles with ≥22 CA repeats had a 5.9 (95% confidence interval, 1.9-18.6; P < .0001) increased odds of TE/A, and a score considering all three variables showed 98% negative predictive value and 30% positive predictive value for thoracic aortic aneurysm detection. Eighty-two popliteal artery enlargements or aneurysms (diameter >10 mm) occurred in 55 patients (33.1% prevalence). Carriers of MMP12 rs652438 C allele showed an 18% (P = .006) increased diameter in popliteal arteries and a 2.8 (95% confidence interval, 1.3-6; P = .008) increased odds of popliteal artery enlargement or aneurysm compared with TT genotype. Among patients with AAA, carriers of homozygous ≥22 CA repeats in MMP9 rs12234681 and of C allele in MMP12 rs652438 have a substantial risk of carrying thoracic and popliteal enlargements, respectively. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  10. Retinal vessel diameters and reactivity in diabetes mellitus and/or cardiovascular disease.

    PubMed

    Heitmar, R; Lip, G Y H; Ryder, R E; Blann, A D

    2017-04-26

    Retinal vessel calibre and vascular dilation/constriction in response to flicker light provocation may provide a measure distinguishing patients suffering from diabetes mellitus and/or cardiovascular disease. One hundred and sixteen age and sex matched patients with diabetes mellitus (DM), cardiovascular disease (CVD) and both DM and CVD (DM + CVD) underwent systemic and intraocular pressure measurements. Retinal vessel calibres were assessed using a validated computer-based program to compute central retinal artery and vein equivalents (CRVE) from monochromatic retinal images. Vessel dilation and constriction responses to flicker light provocation were assessed by continuous retinal vessel diameter recordings. Plasma endothelial markers von Willebrand factor (vWf) and soluble E selectin (sEsel) were measured by ELISA. Retinal vessel calibres were comparable across groups but CRVE correlated significantly with disease duration in DM patients (r = 0.57, p < 0.001). Patients suffering DM only exhibited reduced arterial vasomotion at rest and reduced arterial constriction following flicker light induced vessel dilation compared to patients with CVD and those suffering both CVD + DM (p = 0.030). Patients suffering from CVD + DM exhibited significant differences between each flicker cycle in regards to arterial maximum constriction (p = 0.006) and time needed to reach arterial maximum dilation (p = 0.004), whereas the other two groups did not show such inconsistencies between individual flicker cycles. vWf was raised in CVD + DM compared to the other two groups (p ≤ 0.02), whilst sEsel was raised in CVD + DM compared to DM alone (p = 0.044). Dynamic retinal vascular calibres as obtained by continuous diameter measurements using flicker light provocation can reveal subtle differences between groups suffering from CVD with and without DM. This difference in reaction pattern and lack of arterial constriction in DM may provide a suitable marker to monitor progression.

  11. [Role of endothelium-derived nitric oxide in sustained flow-dependent dilatation of human peripheral conduit arteries].

    PubMed

    Bellien, J; Joannidès, R; Iacob, M; Eltchaninoff, H; Thuillez, Ch

    2003-01-01

    Endothelial dysfunction is involved in the pathogenesis of cardiovascular diseases and is generally associated to the decrease in arterial nitric oxide (NO) availability. In humans, endothelial function can be evaluated by the post-ischaemic flow-dependent dilatation (FDD) of peripheral conduit arteries which is mainly mediated by the NO release when short duration of reactive hyperaemia are used (3 to 5 min ischaemia). However, recent studies suggest that the role of NO in this response decreases as the duration of the hyperaemic stimulation increases. The aim of the present study was thus, to evaluate, in healthy subjects, the role of NO in the FDD of conduct arteries in response to a sustained stimulation. Radial artery diameter (echotracking) and flow (Doppler) were measured, 7 cm under the elbow line, at baseline and during post-ischaemic hyperaemia (10 min wrist cuff inflation) in 10 healthy subjects (age: 24 +/- 1 years) in control period and after acute blockade of the endothelial NO-synthase by local infusion of NG-monomethyl L-arginine (L-NMMA, brachial artery, 8 mumol/min, 7 min). Endothelium-independent dilatation was studied by mean of sodium nitroprusside infusion (SNP: 5, 10 and 20 nmol/min, 3 min each dose before and after L-NMMA). L-NMMA administration decreased radial artery blood flow at base (Control: 14 +/- 2 vs L-NMMA: 10 +/- 1 ml/min, P < 0.05) and increased radial artery vasodilatation in response to SNP (P < 0.05) thus, demonstrating NO-synthase inhibition. Therefore, after L-NMMA there was a small decrease in radial FDD (Control: base: 2.52 +/- 0.05 mm, FDD: 11.3 +/- 0.6% vs L-NMMA: base: 2.51 +/- 0.04 mm: FDD: 9.0 +/- 0.9%; p < 0.05) without change in hyperaemia. In conclusion, our results demonstrate, in contrast to those obtained after short duration of hyperaemia, that the relative implication of NO in the flow-dependent vasodilatation of peripheral conduit arteries in humans decreases in response to sustained stimulation and suggest, in these experimental conditions, an associated flow-dependent vasodilating mechanism that is unaffected by the NO-synthase inhibition.

  12. Distortion of KB estimates of endothelin-1 ETA and ETB receptor antagonists in pulmonary arteries: Possible role of an endothelin-1 clearance mechanism.

    PubMed

    Angus, James A; Hughes, Richard J A; Wright, Christine E

    2017-12-01

    Dual endothelin ET A and ET B receptor antagonists are approved therapy for pulmonary artery hypertension (PAH). We hypothesized that ET B receptor-mediated clearance of endothelin-1 at specific vascular sites may compromise this targeted therapy. Concentration-response curves (CRC) to endothelin-1 or the ET B agonist sarafotoxin S6c were constructed, with endothelin receptor antagonists, in various rat and mouse isolated arteries using wire myography or in rat isolated trachea. In rat small mesenteric arteries, bosentan displaced endothelin-1 CRC competitively indicative of ET A receptor antagonism. In rat small pulmonary arteries, bosentan 10 μmol L -1 left-shifted the endothelin-1 CRC, demonstrating potentiation consistent with antagonism of an ET B receptor-mediated endothelin-1 clearance mechanism. Removal of endothelium or L-NAME did not alter the EC 50 or Emax of endothelin-1 nor increase the antagonism by BQ788. In the presence of BQ788 and L-NAME, bosentan displayed ET A receptor antagonism. In rat trachea (ET B ), bosentan was a competitive ET B antagonist against endothelin-1 or sarafotoxin S6c. Modeling showed the importance of dual receptor antagonism where the potency ratio of ET A to ET B antagonism is close to unity. In conclusion, the rat pulmonary artery is an example of a special vascular bed where the resistance to antagonism of endothelin-1 constriction by ET dual antagonists, such as bosentan or the ET B antagonist BQ788, is possibly due to the competition of potentiation of endothelin-1 by blockade of ET B -mediated endothelin-1 clearance located on smooth muscle and antagonism of ET A - and ET B -mediated contraction. This conclusion may have direct application for the efficacy of endothelin-1 antagonists for treating PAH. © 2017 The Authors. Pharmacology Research & Perspectives published by John Wiley & Sons Ltd, British Pharmacological Society and American Society for Pharmacology and Experimental Therapeutics.

  13. Quality of Construction Central Artery / Third Harbor Tunnel Federal Highway Administration Region 1

    DOT National Transportation Integrated Search

    1996-12-19

    The objective of this audit was to evaluate the Federal Highway : Administration's (FHWA) oversight of the Central Artery / Third Harbor Tunnel : Project's (Project) testing procedures to ensure construction was completed in : accordance with applica...

  14. Two-way FSI modelling of blood flow through CCA accounting on-line medical diagnostics in hypertension

    NASA Astrophysics Data System (ADS)

    Czechowicz, K.; Badur, J.; Narkiewicz, K.

    2014-08-01

    Flow parameters can induce pathological changes in the arteries. We propose a method to asses those parameters using a 3D computer model of the flow in the Common Carotid Artery. Input data was acquired using an automatic 2D ultrasound wall tracking system. This data has been used to generate a 3D geometry of the artery. The diameter and wall thickness have been assessed individually for every patient, but the artery has been taken as a 75mm straight tube. The Young's modulus for the arterial walls was calculated using the pulse pressure, diastolic (minimal) diameter and wall thickness (IMT). Blood flow was derived from the pressure waveform using a 2-parameter Windkessel model. The blood is assumed to be non-Newtonian. The computational models were generated and calculated using commercial code. The coupling method required the use of Arbitrary Lagrangian-Euler formulation to solve Navier-Stokes and Navier-Lame equations in a moving domain. The calculations showed that the distention of the walls in the model is not significantly different from the measurements. Results from the model have been used to locate additional risk factors, such as wall shear stress or circumferential stress, that may predict adverse hypertension complications.

  15. Carbon monoxide inhalation induces headache in a human headache model.

    PubMed

    Arngrim, Nanna; Schytz, Henrik Winther; Britze, Josefine; Vestergaard, Mark Bitsch; Sander, Mikael; Olsen, Karsten Skovgaard; Olesen, Jes; Ashina, Messoud

    2018-04-01

    Introduction Carbon monoxide (CO) is an endogenously produced signalling molecule that has a role in nociceptive processing and cerebral vasodilatation. We hypothesized that inhalation of CO would induce headache and vasodilation of cephalic and extracephalic arteries. Methods In a randomized, double-blind, placebo-controlled crossover design, 12 healthy volunteers were allocated to inhalation of CO (carboxyhemoglobin 22%) or placebo on two separate days. Headache was scored on a verbal rating scale from 0-10. We recorded mean blood velocity in the middle cerebral artery (VMCA) by transcranial Doppler, diameter of the superficial temporal artery (STA) and radial artery (RA) by high-resolution ultrasonography and facial skin blood flow by laser speckle contrast imaging. Results Ten volunteers developed headache after CO compared to six after placebo. The area under the curve for headache (0-12 hours) was increased after CO compared with placebo ( p = 0.021). CO increased VMCA ( p = 0.002) and facial skin blood flow ( p = 0.012), but did not change the diameter of the STA ( p = 0.060) and RA ( p = 0.433). Conclusion In conclusion, the study demonstrated that CO caused mild prolonged headache but no arterial dilatation in healthy volunteers. We suggest this may be caused by a combination of hypoxic and direct cellular effects of CO.

  16. Direct evidence for the role of caveolin-1 and caveolae in mechanotransduction and remodeling of blood vessels

    PubMed Central

    Yu, Jun; Bergaya, Sonia; Murata, Takahisa; Alp, Ilkay F.; Bauer, Michael P.; Lin, Michelle I.; Drab, Marek; Kurzchalia, Teymuras V.; Stan, Radu V.; Sessa, William C.

    2006-01-01

    Caveolae in endothelial cells have been implicated as plasma membrane microdomains that sense or transduce hemodynamic changes into biochemical signals that regulate vascular function. Therefore we compared long- and short-term flow-mediated mechanotransduction in vessels from WT mice, caveolin-1 knockout (Cav-1 KO) mice, and Cav-1 KO mice reconstituted with a transgene expressing Cav-1 specifically in endothelial cells (Cav-1 RC mice). Arterial remodeling during chronic changes in flow and shear stress were initially examined in these mice. Ligation of the left external carotid for 14 days to lower blood flow in the common carotid artery reduced the lumen diameter of carotid arteries from WT and Cav-1 RC mice. In Cav-1 KO mice, the decrease in blood flow did not reduce the lumen diameter but paradoxically increased wall thickness and cellular proliferation. In addition, in isolated pressurized carotid arteries, flow-mediated dilation was markedly reduced in Cav-1 KO arteries compared with those of WT mice. This impairment in response to flow was rescued by reconstituting Cav-1 into the endothelium. In conclusion, these results showed that endothelial Cav-1 and caveolae are necessary for both rapid and long-term mechanotransduction in intact blood vessels. PMID:16670769

  17. Randomized Comparison of Paclitaxel-Eluting Balloon and Stenting Versus Plain Balloon Plus Stenting Versus Directional Atherectomy for Femoral Artery Disease (ISAR-STATH).

    PubMed

    Ott, Ilka; Cassese, Salvatore; Groha, Philipp; Steppich, Birgit; Hadamitzky, Martin; Ibrahim, Tareq; Kufner, Sebastian; Dewitz, Karl; Hiendlmayer, Regina; Laugwitz, Karl-Ludwig; Schunkert, Heribert; Kastrati, Adnan; Fusaro, Massimiliano

    2017-06-06

    Atherosclerosis in the superficial femoral artery is common in patients suffering from peripheral artery disease. Paclitaxel-eluting balloon (PEB) angioplasty, stenting, and directional atherectomy (DA) have provided new options for the treatment of superficial femoral artery disease; however, the comparative efficacy of these interventional strategies remains uncertain. One hundred and fifty-five patients with symptomatic peripheral artery disease due to de novo superficial femoral artery stenotic or occlusive lesions were randomized to treatment with plain balloon angioplasty (BA) followed by PEB angioplasty and stenting (n=48), BA and stenting (n=52), or DA with distal protection and bailout stenting (n=55). The primary end point of the study was percentage diameter stenosis after 6 months measured by angiography. Other end points included target lesion revascularization, thrombosis, ipsilateral amputation, binary restenosis, and all-cause mortality at 6 and 24 months. Baseline and lesion characteristics were comparable in all groups with a mean lesion length of 65.9±46.8 mm and 56% total occlusions. At 6 months angiography, the percent diameter stenosis was significantly lower in patients treated by PEB angioplasty and stenting (34±31%) as compared with BA angioplasty and stenting (56±29%, P =0.009) or DA (55±29%, P =0.007). Similarly, binary restenosis was significantly lower after treatment with PEB and stenting as compared with BA and stenting or DA. Clinical follow-up at 24 months revealed a lower risk for target lesion revascularization after PEB angioplasty and stenting as compared with BA and stenting or DA. We found no difference in terms of target lesion thrombosis and mortality among groups, and no patient underwent amputation. Treatment of de novo superficial femoral artery lesions with PEB angioplasty and stenting is superior to BA angioplasty and stenting or DA in terms of angiographic diameter stenosis at 6 months and target lesion revascularization at 24 months. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00986752. © 2017 American Heart Association, Inc.

  18. Long-term follow-up after deferral of coronary intervention based on myocardial fractional flow reserve measurement.

    PubMed

    Mates, Martin; Hrabos, Vladimir; Hajek, Petr; Rataj, Ondrej; Vojacek, Jan

    2005-05-01

    To assess long-term results after deferring coronary intervention (percutaneous coronary intervention (PCI)) of an intermediate lesion with a value of myocardial fractional flow reserve (FFR) > or = 0.75 in a 'real life' patient population with no respect to results of stress tests (if performed) or coronary disease extent. PCI of an intermediate lesion was deferred in a group of 85 consecutive patients (54 men, 61+/-10 years) on the basis of the result of FFR > or = 0.75 (mean FFR, 0.89+/-0.06%). FFR was measured in 111 stenoses (mean diameter stenosis, 54+/-8%, left anterior descending coronary artery, 65 (58%), left circumflex coronary artery, 24 (22%), right coronary artery, 22 (20%). Multi-vessel disease (defined as visually assessed diameter reduction of more than 50% in at least two arteries of more than 1.5 mm diameter, supplying at least two of the three major coronary artery perfusion territories) was present in 67% of patients (one-vessel disease, 28 patients (33%), two-vessel disease, 39 patients (46%), three-vessel disease, 18 patients (21%). Recorded events during follow-up were as follows: all-cause death, cardiac death, non-fatal myocardial infarction, ischemia-driven target lesion transcatheter revascularization (TLR) and coronary artery bypass graft (CABG). Angina class (Canadian Cardiovascular Society (CCS) classification) and the need for anti-anginal drugs were recorded. Follow-up was completed in 85 patients (100%). Mean duration of follow-up was 22.6+/-6.6 months (range 4-33 months). Events occurred in 11 patients (13%). Seven patients died; this included two cardiac deaths. A non-fatal myocardial infarction occurred in one patient, one patient needed TLR and three patients underwent CABG. Estimated 33 month cardiac-event-free survival (Kaplan-Meier) was 91+/-4%. Angina class decreased [1.6+/-1.2 compared with 0.8+/-0.8 (P < 0.0001)] without difference with respect to the use of anti-anginal drugs (1.7+/-0.8 compared with 1.7+/-0.9, P = NS). Deferring coronary interventions of intermediate stenosis based on FFR measurement is safe with respect to long-term follow-up, irrespective of the extent of coronary artery disease.

  19. Non-valvular main pulmonary artery vegetation associated with aortopulmonary window.

    PubMed

    Unal, M; Tuncer, C; Serçe, K; Bostan, M; Gökçe, M; Erem, C

    1995-01-01

    We present a 32-year-old female with aortopulmonary window and vegetation of non-valvular main pulmonary artery. The aortopulmonary window is a rare congenital disease in which the aorta and pulmonary arteries are communicated by a defect of variable diameter. The pulmonic valve is the least commonly involved valve in bacterial endocarditis, but there is no vegetation of non-valvular main pulmonary artery in the literature. Colour duplex sonography showed an aortopulmonary window with aortic regurgitation. Magnetic resonance (MR) imaging demonstrating the vegetation on the wall of main pulmonary artery, is an useful and complementary method, and can be used for demonstration of congenital and acquired cardiovascular pathologies including aortopulmonary window and subpulmonic or suprapulmonic vegetations.

  20. Ambiguities in the definition of quasilocal mass

    NASA Technical Reports Server (NTRS)

    Woodhouse, N. M. J.

    1987-01-01

    For a small surface in a vacuum spacetime, some components of the kinematic twistor are nonzero at the fifth order in the diameter of the surface even though, according to Penrose's (1986) modified construction, the leading term in the quasi-local mass m(p) is sixth order (or higher). This implies that the leading term in m(p) cannot be defined independently of higher-order terms in the twistor norm.

  1. Relationship between aneurysm occlusion and flow diverting device oversizing in a rabbit model.

    PubMed

    Hodis, Simona; Ding, Yong-Hong; Dai, Daying; Lingineni, Ravi; Mut, Fernando; Cebral, Juan; Kallmes, David; Kadirvel, Ramanathan

    2016-01-01

    Implanted, actual flow diverter pore density is thought to be strongly influenced by proper matching between the device size and parent artery diameter. The objective of this study was to characterize the correlation between device sizing, metal coverage, and the resultant occlusion of aneurysms following flow diverter treatment in a rabbit model. Rabbit saccular aneurysms were treated with flow diverters (iso-sized to proximal parent artery, 0.5 mm oversized, or 1.0 mm oversized, respectively, n=6 for each group). Eight weeks after implantation, the angiographic degree of aneurysm occlusion was graded (complete, near-complete, or incomplete). The ostium of the explanted aneurysm covered with the flow diverter struts was photographed. Based on gross anatomic findings, the metal coverage and pore density at the ostium of the aneurysm were calculated and correlated with the degree of aneurysm occlusion. Angiographic results showed there were no statistically significant differences in aneurysm geometry and occlusion among groups. The mean parent artery diameter to flow diverter diameter ratio was higher in the 1.0 mm oversized group than in the other groups. Neither the percentage metal coverage nor the pore density showed statistically significant differences among groups. Aneurysm occlusion was inversely correlated with the ostium diameter, irrespective of the size of the device implanted. Device sizing alone does not predict resultant pore density or metal coverage following flow diverter implantation in the rabbit aneurysm model. Aneurysm occlusion was not impacted by either metal coverage or pore density, but was inversely correlated with the diameter of the ostium. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  2. Sublingual Nitroglycerin Administration in Coronary Computed Tomography Angiography: a Systematic Review.

    PubMed

    Takx, Richard A P; Suchá, Dominika; Park, Jakob; Leiner, Tim; Hoffmann, Udo

    2015-12-01

    To systematically investigate the literature for the influence of sublingual nitroglycerin administration on coronary diameter, the number of evaluable segments, image quality, heart rate and blood pressure, and diagnostic accuracy of coronary computed tomography (CT) angiography. A systematic search was performed in PubMed, EMBASE and Web of Science. The studies were evaluated for the effect of sublingual nitroglycerin on coronary artery diameter, evaluable segments, objective and subjective image quality, systemic physiological effects and diagnostic accuracy. Due to the heterogeneous reporting of outcome measures, a narrative synthesis was applied. Of the 217 studies identified, nine met the inclusion criteria: seven reported on the effect of nitroglycerin on coronary artery diameter, six on evaluable segments, four on image quality, five on systemic physiological effects and two on diagnostic accuracy. Sublingual nitroglycerin administration resulted in an improved evaluation of more coronary segments, in particular, in smaller coronary branches, better image quality and improved diagnostic accuracy. Side effects were mild and were alleviated without medical intervention. Sublingual nitroglycerin improves the coronary diameter, the number of assessable segments, image quality and diagnostic accuracy of coronary CT angiography without major side effects or systemic physiological changes. • Sublingual nitroglycerin administration results in significant coronary artery dilatation. • Nitroglycerin increases the number of evaluable coronary branches. • Image quality is improved the most in smaller coronary branches. • Nitroglycerin increases the diagnostic accuracy of coronary CT angiography. • Most side effects are mild and do not require medical intervention.

  3. Motion Tolerant Unfocused Imaging of Physiological Waveforms for Blood Pressure Waveform Estimation Using Ultrasound.

    PubMed

    Seo, Joohyun; Pietrangelo, Sabino J; Sodini, Charles G; Lee, Hae-Seung

    2018-05-01

    This paper details unfocused imaging using single-element ultrasound transducers for motion tolerant arterial blood pressure (ABP) waveform estimation. The ABP waveform is estimated based on pulse wave velocity and arterial pulsation through Doppler and M-mode ultrasound. This paper discusses approaches to mitigate the effect of increased clutter due to unfocused imaging on blood flow and diameter waveform estimation. An intensity reduction model (IRM) estimator is described to track the change of diameter, which outperforms a complex cross-correlation model (C3M) estimator in low contrast environments. An adaptive clutter filtering approach is also presented, which reduces the increased Doppler angle estimation error due to unfocused imaging. Experimental results in a flow phantom demonstrate that flow velocity and diameter waveforms can be reliably measured with wide lateral offsets of the transducer position. The distension waveform estimated from human carotid M-mode imaging using the IRM estimator shows physiological baseline fluctuations and 0.6-mm pulsatile diameter change on average, which is within the expected physiological range. These results show the feasibility of this low cost and portable ABP waveform estimation device.

  4. Accuracy Evaluation in the Measurement of a Small Change in the Thickness of Arterial Walls and the Measurement of Elasticity of the Human Carotid Artery

    NASA Astrophysics Data System (ADS)

    Hasegawa, Hideyuki; Kanai, Hiroshi; Hoshimiya, Nozomu; Chubachi, Noriyoshi; Koiwa, Yoshiro

    1998-05-01

    For the diagnosis of the early stages of atherosclerosis, it isimportant to evaluate the local acoustic characteristics of thearterial wall. For this purpose, it is necessary to increase thespatial resolution in the axial direction to several millimeters,which corresponds to the size of the macular lesion on the surface ofthe wall. We have proposed a method for measuring small velocitysignals on the intima and adventitia of the arterial wall from theskin surface using pulsive ultrasonic waves. The small change inthickness of the arterial wall is obtained by integrating thedifference between the two velocity signals on the intima andadventitia. The elastic property of the arterial wall is noninvasivelyevaluated from the change in thickness and the arterial innerpressure. In this paper, we evaluate the accuracy of the proposedmethod for measuring the small displacement. Moreover, we applied thismethod to evaluate the elastic property of the arterial wall of 50patients and 8 healthy subjects.

  5. Transcatheter Arterial Embolization for Spontaneous Rupture of the Omental Artery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Matsumoto, Tomohiro, E-mail: t-matsu@koto.kpu-m.ac.jp; Yamagami, Takuji; Morishita, Hiroyuki

    We encountered a rare case of spontaneous rupture of the omental artery. A 25-year-old man without any episode of abdominal trauma or bleeding disorders came to the emergency unit with left upper abdominal pain. Hematoma with extravasation of the greater omentum and a hemoperitoneum was confirmed on abdominal contrast-enhanced computed tomography. Bleeding from the omental artery was suspected based on these findings. Transcatheter arterial embolization was successfully performed after extravasation of the omental artery, which arises from the left gastroepiploic artery, was confirmed on arteriography. Partial ometectomy was performed 10 days after transcatheter arterial embolization, revealing that the hematoma measuredmore » 10 cm in diameter in the greater omentum. Pathological examination showed rupture of the branch of an omental artery without abnormal findings, such as an aneurysm or neoplasm. Thus, we diagnosed him with spontaneous rupture of the omental artery. The patient recovered and was discharged from the hospital 10 days after the surgery, with a favorable postoperative course.« less

  6. [Significance of heterogenity in endothelium-dependent vasodilatation occurrence in healthy individuals with or without coronary risk factors].

    PubMed

    Polovina, Marija; Potpara, Tatjana; Giga, Vojislav; Ostojić, Miodrag

    2009-10-01

    Brachial artery flow-mediated dilation (FMD) is extensively used for non-invasive assessment of endothelial function. Traditionally, FMD is calculated as a percent change of arterial diameter from the baseline value at an arbitrary time point after cuff deflation (usually 60 seconds). Considerable individual differences in brachial artery temporal response to hyperemic stimulus have been observed, potentially influenced by the presence of atherosclerotic risk factors (RF). The importance of such differences for the evaluation of endothelial function has not been well established. The aim of the study was to determine the time course of maximal brachial artery endothelium-dependent dilation in healthy adults with and without RF, to explore the correlation of RF with brachial artery temporal response and to evaluate the importance of individual differences in temporal response for the assessment of endothelial function. A total of 115 healthy volunteers were included in the study. Out of them, 58 had no RF (26 men, mean age 44 +/-14 years) and 57 had at least one RF (29 men, mean age 45 +/-14 years). High-resolution color Doppler vascular ultrasound was used for brachial artery imaging. To determine maximal arterial diameter after cuff deflation and the time-point of maximal vasodilation off-line sequential measurements were performed every 10 seconds from 0 to 240 seconds after cuff release. True maximal FMD value was calculated as a percent change of the true maximal diameter from the baseline, and compared with FMD value calculated assuming that every participant reached maximal dilation at 60 seconds post cuff deflation (FMD60). Correlation of different RF with brachial artery temporal response was assessed. A maximal brachial artery endothelium-dependent vasodilation occurred from 30-120 seconds after cuff release, and the mean time of endothelium-dependent dilation was 68 +/-20 seconds. Individuals without RF had faster endothelium-dependent dilation (mean time 62 +/-17 seconds), and a shorter time-span (30 to 100 seconds), than participants with RF (mean time 75 +/-21 seconds, time-span 40 to 120 seconds) (p < 0.001). Time when the maximal endothelium-dependent dilation occurred was independently associated with age, serum lipid fractions (total cholesterol, LDL and HDL cholesterol), smoking, physical activity and C-reactive protein. True maximal FMD value in the whole group (6.7 +/-3.0%) was significantly higher (p < 0.001) than FMD60 (5.2 +/-3.5%). The same results were demonstrated for individuals with RF (4.9 +/- 1.7% vs 3.1 +/- 2.3%, p < 0.001) and without RF (8.4 +/- 2.9% vs 7.2 +/- 3.2%, p < 0.05). The temporal response of endothelium-dependent dilation is influenced by the presence of coronary FR and individually heterogeneous. When calculated according to the commonly used approach, i.e. 60 seconds after cuff deflation, FMD is significantly lower than the true maximal FMD. The routinely used measurement time-points for FMD assessment may not be adequate for the detection of true peak vasodilation in individual persons. More precise evaluation of endothelial function can be achieved with sequential measurement of arterial diameter after hyperemic stimulus.

  7. Pulmonary hypertension due to left heart disease: diagnostic and prognostic value of CT in chronic systolic heart failure.

    PubMed

    Colin, Geoffrey C; Gerber, Bernhard L; de Meester de Ravenstein, Christophe; Byl, David; Dietz, Anna; Kamga, Michele; Pasquet, Agnes; Vancraeynest, David; Vanoverschelde, Jean-Louis; D'Hondt, Anne-Marie; Ghaye, Benoit; Pouleur, Anne-Catherine

    2018-05-14

    To evaluate the ability of chest computed tomography (CT) to predict pulmonary hypertension (PH) and outcome in chronic heart failure with reduced ejection fraction (HFrEF). We reviewed 119 consecutive patients with HFrEF by CT, transthoracic echocardiography (TTE) and right heart catheterization (RHC). CT-derived pulmonary artery (PA) diameter and PA to ascending aorta diameter ratio (PA:A ratio), left atrial, right atrial, right ventricular (RV) and left ventricular volumes were correlated with RHC mean pulmonary arterial pressure (mPAP) . Diagnostic accuracy to predict PH and ability to predict primary composite endpoint of all-cause mortality and HF events were evaluated. RV volume was significantly higher in 81 patients with PH compared to 38 patients without PH (133 ml/m 2 vs. 79 ml/m 2 , p < 0.001) and was moderately correlated with mPAP (r=0.55, p < 0.001). Also, RV volume had higher ability to predict PH (area under the curve: 0.88) than PA diameter (0.79), PA:A ratio (0.76) by CT and tricuspid regurgitation gradient (0.83) and RV basal diameter by TTE (0.84, all p < 0.001). During the follow-up period (median: 3.4 years), 51 patients (43%) had HF events or died. After correction for important clinical, TTE and RHC parameters, RV volume (adjusted hazard ratio [HR]: 1.71, 95% CI 1.31-2.23, p < 0.001) and PA diameter (HR: 1.61, 95% CI 1.18-2.22, p = 0.003) were independent predictors of the primary endpoint. In patients with HFrEF, measurement of RV volume and PA diameter on ungated CT are non-invasive markers of PH and may help to predict the patient outcome. • Right ventricular (RV) volume measured by chest CT has good ability to identify pulmonary hypertension (PH) in patients with chronic heart failure (HF) and reduced ejection fraction (HFrEF). • The accuracy of pulmonary artery (PA) diameter and PA to ascending aorta diameter ratio (PA:A ratio) to predict PH was similar to previous studies, however, with lower cut-offs (28.1 mm and 0.92, respectively). • Chest CT-derived PA diameter and RV volume independently predict all-cause mortality and HF events and improve outcome prediction in patients with advanced HFrEF.

  8. Topical nitroglycerin and lidocaine locally vasodilate the radial artery without affecting systemic blood pressure: a dose-finding phase I study.

    PubMed

    Majure, David T; Hallaux, Melanie; Yeghiazarians, Yerem; Boyle, Andrew J

    2012-10-01

    Small radial artery diameter (RAD) and vasospasm are barriers to radial artery cannulation. We performed this study to determine if topical nitroglycerin and/or nitroglycerin plus topical lidocaine increases RAD without affecting systemic blood pressure. This was a randomized, double-blind, placebo-controlled study. In the first visit, to determine the optimal dose of nitroglycerin, subjects were randomized to either 15 or 30 mg nitroglycerin on one wrist and placebo on the other. In visit 2, to assess for any effect of lidocaine on the vasodilator function of nitroglycerin, the same subjects were randomized to 20 mg lidocaine + 30 mg nitroglycerin vs 20 mg lidocaine + placebo, or 40 mg lidocaine + 30 mg nitroglycerin vs 40 mg lidocaine + placebo. In both visits, blood pressure and RAD using ultrasonography were measured for 2 hours. In visit 1, both nitroglycerin groups significantly increased RAD, with greater increases with 30 mg nitroglycerin (P < .01) and no significant increase in RAD in placebo wrists. In visit 2, increase in RAD was significantly greater with 20 mg lidocaine + 30 mg nitroglycerin vs 20 mg lidocaine + placebo (P < .001), and 40 mg lidocaine + 30 mg nitroglycerin vs 40 mg lidocaine + placebo (P < .001), indicating that lidocaine does not alter the effect of nitroglycerin. There were significant increases in RAD seen as early as 30 minutes. There were no significant change in RAD in lidocaine + placebo-treated wrists and no change in blood pressure in any group. Topical nitroglycerin and lidocaine significantly increase RAD within 30 to 60 minutes with no effect on contralateral radial artery or blood pressure, indicating a direct, local effect on the radial artery. (Clinicaltrials.gov number NCT00686231). Copyright © 2012 Elsevier Inc. All rights reserved.

  9. THE STATE OF THE VESSELS OF THE MESENTERY IN SHOCK PRODUCED BY CONSTRICTING THE LIMBS AND THE BEHAVIOR OF THE VESSELS FOLLOWING HEMORRHAGE

    PubMed Central

    Page, Irvine H.; Abell, Richard G.

    1943-01-01

    1. Direct observations of the arteries, arterioles, capillaries, veins, and lymphatics in the mesentery of anesthetized cats put into shock by incomplete occlusion of the circulation of the limbs showed that: (a) Marked constriction of the arteries and arterioles, produced by muscular contraction, occurred usually within an hour after incomplete occlusion of the limbs, lasted several hours, and finally gave way in most instances to relaxation an hour or more before death. The constriction reduced the blood supply to the mesentery and intestine and the venous return from them. It did not, however, interrupt the blood flow. No pooling or stagnation of blood was seen even as a terminal phenomenon. (b) The veins of the mesentery also became constricted but showed less tendency to dilate as death approached. The lymphatics likewise became somewhat narrowed. Even during the terminal stage the leukocytes moved along without change in shape or sticking to the walls of the capillaries or venules. (c) Hematocrit determinations showed progressive hemoconcentration of moderate degree. (d) Autopsy usually showed the presence of small hemorrhages in many parts of the body, especially the heart, liver, spleen, and lungs. (e) Bilateral nephrectomy, suprarenalectomy, and pancreatectomy did not significantly alter the morphological picture elicited by shock induced by restriction of the circulation to the limbs. 2. Removal of large amounts of blood was always followed within a short time by constriction of arteries, arterioles, veins, and lymphatics of the mesentery. 3. Fall in arterial pressure produced by pithing was not accompanied by change in diameter of the arteries, arterioles, veins, or lymphatics, or by blanching of the mesentery or gut. PMID:19871278

  10. Effect of antihypertensive therapy on renal artery structure in type 2 diabetic rats with hypertension.

    PubMed

    Reddi, A S; Nimmagadda, V R; Arora, R

    2001-05-01

    We have previously demonstrated that antihypertensive treatment with doxazosin (DZN), an alpha-adrenergic blocker, and lisinopril (LIS), an ACE inhibitor, reverse glomerular sclerosis in corpulent spontaneously hypertensive rats with type 2 diabetes. In this study, we examined the effects of the above-mentioned antihypertensive drugs alone and in combination on the structure of interlobular and arcuate arteries in these rats. Both male and female rats aged 6 months were treated with antihypertensive drugs for 16 weeks. Various structural parameters were evaluated by light microscopy, with the use of digital image analysis, in kidney sections stained with periodic acid-SCHIFF: Systolic blood pressure was significantly lower in treated than in untreated rats. Untreated diabetic rats had a significantly higher media/lumen ratio (smaller luminal diameter) of both arteries compared with the ratio in treated rats (for interlobular artery, 0.72+/-0.06 [no treatment], 0.49+/-0.03 [DZN treatment], 0.54+/-0.06 [LIS treatment], and 0.52+/-0.04 [combination therapy], P<0.05 to <0.001 for no treatment versus treatment; for arcuate artery, 0.66+/-0.11 [no treatment], 0.40+/-0.02 [DZN treatment], 0.39+/-0.04 [LIS treatment], and 0.40+/-0.03 [combination therapy], P<0.05 for no treatment versus treatment). Antihypertensive treatment caused significant increases in total arterial cross-sectional area, internal and external diameters, luminal and medial cross-sectional area, and medial thickness in both interlobular and arcuate arteries. The improvement in arterial structure after antihypertensive treatment was due to remodeling and growth of the vessels. Both DZN and LIS were equally efficacious, and combination therapy had no additive or synergistic effect.

  11. Spaceflight on the Bion-M1 biosatellite alters cerebral artery vasomotor and mechanical properties in mice

    PubMed Central

    Sofronova, Svetlana I.; Tarasova, Olga S.; Gaynullina, Dina; Borzykh, Anna A.; Behnke, Bradley J.; Stabley, John N.; McCullough, Danielle J.; Maraj, Joshua J.; Hanna, Mina; Muller-Delp, Judy M.; Vinogradova, Olga L.

    2015-01-01

    Conditions during spaceflight, such as the loss of the head-to-foot gravity vector, are thought to potentially alter cerebral blood flow and vascular resistance. The purpose of the present study was to determine the effects of long-term spaceflight on the functional, mechanical, and structural properties of cerebral arteries. Male C57BL/6N mice were flown 30 days in a Bion-M1 biosatellite. Basilar arteries isolated from spaceflight (SF) (n = 6), habitat control (HC) (n = 6), and vivarium control (VC) (n = 16) mice were used for in vitro functional and mechanical testing and histological structural analysis. The results demonstrate that vasoconstriction elicited through a voltage-gated Ca2+ mechanism (30–80 mM KCl) and thromboxane A2 receptors (10−8 − 3 × 10−5 M U46619) are lower in cerebral arteries from SF mice. Inhibition of Rho-kinase activity (1 μM Y27632) abolished group differences in U46619-evoked contractions. Endothelium-dependent vasodilation elicited by acetylcholine (10 μM, 2 μM U46619 preconstriction) was virtually absent in cerebral arteries from SF mice. The pressure-diameter relation was lower in arteries from SF mice relative to that in HC mice, which was not related to differences in the extracellular matrix protein elastin or collagen content or the elastin/collagen ratio in the basilar arteries. Diameter, medial wall thickness, and medial cross-sectional area of unpressurized basilar arteries were not different among groups. These results suggest that the microgravity-induced attenuation of both vasoconstrictor and vasodilator properties may limit the range of vascular control of cerebral perfusion or impair the distribution of brain blood flow during periods of stress. PMID:25593287

  12. Stent-assisted coil embolization of aneurysms with small parent vessels: safety and efficacy analysis.

    PubMed

    Kühn, Anna Luisa; Hou, Samuel Y; Puri, Ajit S; Silva, Christine F; Gounis, Matthew J; Wakhloo, Ajay K

    2016-06-01

    Stent-assisted coil embolization (SACE) is a viable therapeutic approach for wide-neck intracranial aneurysms. However, it can be technically challenging in small cerebral vessels (≤2 mm). To present our experience with stents approved for SACE in aneurysms with small parent arteries. All patients who underwent stent-assisted aneurysm treatment with either a Neuroform or an Enterprise stent device at our institution between June 2006 and October 2012 were identified. Additionally, we evaluated each patient's vascular risk factors, aneurysm characteristics (ruptured vs non-ruptured, incidental finding, recanalized) and follow-up angiography data. A total of 41 patients with 44 aneurysms met our criteria, including 31 women and 10 men. Most of the aneurysms were located in the anterior circulation (75%). Stent placement in vessels 1.2-2 mm in diameter was successful in 93.2%. Thromboembolic complications occurred in 6 cases and vessel straightening was seen in 1 case only. Initial nearly complete to complete aneurysm obliteration was achieved in 88.6%. Six-month follow-up angiography showed coil compaction in three cases, one asymptomatic in-stent stenosis and stent occlusion. Twelve to 20-months' follow-up showed stable coil compaction in two patients compared with previous follow-up, and aneurysm recanalization in two patients. Twenty-four to 36-months' follow-up showed further coil compaction in one of these patients and aneurysm recanalization in a previous case of stable coil compaction on mid-term follow-up. Our results suggest that SACE of aneurysms with small parent vessels is feasible in selected cases and shows good long-term patency rates of parent arteries. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  13. Hair Follicle-Derived Smooth Muscle Cells and Small Intestinal Submucosa for Engineering Mechanically Robust and Vasoreactive Vascular Media

    PubMed Central

    Peng, Hao-Fan; Liu, Jin Yu

    2011-01-01

    Our laboratory recently reported a new source of smooth muscle cells (SMCs) derived from hair follicle (HF) mesenchymal stem cells. HF-SMCs demonstrated high proliferation and clonogenic potential as well as contractile function. In this study, we aimed at engineering the vascular media using HF-SMCs and a natural biomaterial, namely small intestinal submucosa (SIS). Engineering functional vascular constructs required application of mechanical force, resulting in actin reorganization and cellular alignment. In turn, cell alignment was necessary for development of receptor- and nonreceptor-mediated contractility as soon as 24 h after cell seeding. Within 2 weeks in culture, the cells migrated into SIS and secreted collagen and elastin, the two major extracellular matrix components of the vessel wall. At 2 weeks, vascular reactivity increased significantly up to three- to fivefold and mechanical properties were similar to those of native ovine arteries. Taken together, our data demonstrate that the combination of HF-SMCs with SIS resulted in mechanically strong, biologically functional vascular media with potential for arterial implantation. PMID:21083418

  14. Usefulness of Cone-Beam Computed Tomography During Ultraselective Transcatheter Arterial Chemoembolization for Small Hepatocellular Carcinomas that Cannot be Demonstrated on Angiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miyayama, Shiro, E-mail: s-miyayama@fukui.saiseikai.or.jp; Yamashiro, Masashi; Okuda, Miho

    2009-03-15

    This study evaluated the usefulness of cone-beam computed tomography (CBCT) during ultraselective transcatheter arterial chemoembolization (TACE) for hepatocellular carcinomas (HCC) that could not be demonstrated on angiography. Twenty-eight patients with 33 angiographically occult tumors (mean diameter 1.3 {+-} 0.3 cm) were enrolled in the study. The ability of CBCT during arterial portography (CBCTAP), during hepatic arteriography (CBCTHA), and after iodized oil injection (LipCBCT) to detect HCC lesions was retrospectively analyzed. The technical success of TACE was divided into three grades: complete (the embolized area included the entire tumor with at least a 5-mm wide margin), adequate (the embolized area includedmore » the entire tumor but without a 5-mm wide margin in parts), and incomplete (the embolized area did not include the entire tumor) according to computed axial tomographic (CAT) images obtained 1 week after TACE. Local tumor progression was also evaluated. CBCTAP, CBCTHA, and LipCBCT detected HCC lesions in 93.9% (31 of 33), 96.7% (29 of 30), and 100% (29 of 29) of patients, respectively. A single branch was embolized in 28 tumors, and 2 branches were embolized in five tumors. Twenty-seven tumors (81.8%) were classed as complete, and 6 (18.2%) were classed as adequate. None of the tumors were classed as incomplete. Twenty-five tumors (75.8%) had not recurred during 12.0 {+-} 6.2 months. Eight tumors (24.2%), 5 (18.5%) of 27 complete success and 3 (50%) of 6 adequate success, recurred during 10.1 {+-} 6.2 months. CBCT during TACE is useful in detecting and treating small HCC lesions that cannot not be demonstrated on angiography.« less

  15. Benefits of Synchrotron Microangiography for Dynamic Studies of Smooth Muscle and Endothelial Roles in the Pathophysiology of Vascular Disease

    NASA Astrophysics Data System (ADS)

    Pearson, James T.; Schwenke, Daryl O.; Jenkins, Mathew J.; Edgley, Amanda J.; Sonobe, Takashi; Ishibashi-Ueda, Hatsue; Umetani, Keiji; Eppel, Gabriela A.; Evans, Roger G.; Okura, Yasuhiko; Shirai, Mikiyasu

    2010-07-01

    Changes in endothelial and smooth muscle function compromise organ perfusion in the chronic disease states of diabetes, atherosclerosis and hypertension. Moreover, vascular dysfunction increases the likelihood of lethal acute events such as myocardial infarction and stroke, which are now leading causes of adult mortality. Many circulating and local tissue factors in these disease states contribute to impaired vasomotor regulation of the arterial vessels, leading to spasm, chronic constriction and eventually vessel remodelling. X-ray contrast absorption imaging allows assessment of vessel lumen diameter and the factors contributing to steady-state vessel calibre, however, conventional clinical devices (>200 μm resolution) are not adequate to detect microvessels or accurately assess function in real time. Using synchrotron imaging we are now able to detect small vessel calibres (˜30 μm) and quantify regional differences in calibre even under conditions of high heart rate (>500 bpm). Herein we describe recent experiments that were conducted at the Japanese Synchrotron, SPring-8 using anaesthetised Sprague-Dawley rats and C57Bl/6 mice and a synchrotron radiation contrast angiography (single narrow energy bandwidth) approach based on selective arterial injection of iodine contrast agents. Application of this approach to imaging of the heart and other vasculatures are described. Our studies show that within-animal comparisons of 3-4 branching orders of arterial vessels are possible using small bolus contrast injections and appropriate contrast washout times (15-30 min) in many organ systems. Determination of relative calibre changes before and after any treatment allows us to evaluate the contributions of different endogenous factors and ligand-receptor pathways in the maintenance of vasomotor tone. Finally, we will present our findings relating to novel therapies to prevent endothelial dysfunction in heart failure.

  16. Benefits of Synchrotron Microangiography for Dynamic Studies of Smooth Muscle and Endothelial Roles in the Pathophysiology of Vascular Disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pearson, James T.; Department of Physiology, Monash University, 3800 Clayton; Schwenke, Daryl O.

    2010-07-23

    Changes in endothelial and smooth muscle function compromise organ perfusion in the chronic disease states of diabetes, atherosclerosis and hypertension. Moreover, vascular dysfunction increases the likelihood of lethal acute events such as myocardial infarction and stroke, which are now leading causes of adult mortality. Many circulating and local tissue factors in these disease states contribute to impaired vasomotor regulation of the arterial vessels, leading to spasm, chronic constriction and eventually vessel remodelling. X-ray contrast absorption imaging allows assessment of vessel lumen diameter and the factors contributing to steady-state vessel calibre, however, conventional clinical devices (>200 {mu}m resolution) are not adequatemore » to detect microvessels or accurately assess function in real time. Using synchrotron imaging we are now able to detect small vessel calibres ({approx}30 {mu}m) and quantify regional differences in calibre even under conditions of high heart rate (>500 bpm). Herein we describe recent experiments that were conducted at the Japanese Synchrotron, SPring-8 using anaesthetised Sprague-Dawley rats and C57Bl/6 mice and a synchrotron radiation contrast angiography (single narrow energy bandwidth) approach based on selective arterial injection of iodine contrast agents. Application of this approach to imaging of the heart and other vasculatures are described. Our studies show that within-animal comparisons of 3-4 branching orders of arterial vessels are possible using small bolus contrast injections and appropriate contrast washout times (15-30 min) in many organ systems. Determination of relative calibre changes before and after any treatment allows us to evaluate the contributions of different endogenous factors and ligand-receptor pathways in the maintenance of vasomotor tone. Finally, we will present our findings relating to novel therapies to prevent endothelial dysfunction in heart failure.« less

  17. Time-of-flight magnetic resonance angiography (TOF-MRA) of the normal equine head.

    PubMed

    Manso-Díaz, G; García-Real, M I; Casteleyn, C; San-Román, F; Taeymans, O

    2013-03-01

    Noncontrast magnetic resonance angiography (MRA) is widely used in human and small animal medicine. However, this technique has not yet been described in the horse, and compared to other angiographic techniques MRA could be more cost efficient and potentially safer. The aim of this study was to provide a comprehensive anatomical reference of the normal equine head vasculature using a noncontrast MRA technique, on both low- and high-field MRI. Five healthy adult horses were examined, 4 with a low-field magnet (0.23T) and the remaining one with a high-field magnet (1.5T). The magnetic resonance angiography sequence used was TOF (time-of-flight) 2D-MRA and CT images of a vascular corrosion cast were subsequently used as anatomical references. The MRA imaging protocol provided good visualisation of all major intra- and extracranial vessels down to a size of approximately 2 mm in diameter on both low- and high-field systems. This resulted in identification of vessels to the order of 3rd-4th branches of ramification. The visibility of the arteries was higher than of the veins, which showed lower signal intensity. Overall, MRA obtained with the high-field protocol provided better visualisation of the arteries, showing all the small arterial branches with a superior resolution. The use of a specific vascular sequence such as TOF 2D-MRA allows good visualisation of the equine head vasculature and eliminates the need for contrast media for MRA. Magnetic resonance angiography allows for visualisation of the vasculature of the equine head. Vessel morphology, symmetry and size can be evaluated and this may possibly play a role in preoperative planning or characterisation of diseases of the head, such as neoplasia or guttural pouch mycosis. © 2012 EVJ Ltd.

  18. A New Flow-Diverter (the FloWise): In-Vivo Evaluation in an Elastase-Induced Rabbit Aneurysm Model.

    PubMed

    Kim, Byung Moon; Kim, Dong Joon; Kim, Dong Ik

    2016-01-01

    We aimed to evaluate the efficacy and safety of a newly developed, partially retrievable flow-diverter (the FloWise) in an elastase-induced rabbit aneurysm model. We developed a partially retrievable flow diverter composed of 48 strands of Nitinol and platinum wire. The FloWise is compatible with any microcatheter of 0.027-inch inner diameter, and is retrievable up to 70% deployment. The efficacy and safety of the FloWise were evaluated in the elastase-induced rabbit aneurysm model. The rate of technical success (full coverage of aneurysm neck) and assessment of aneurysm occlusion and stent patency was conducted by angiograms and histologic examinations at the 1-month, 3-month, and 6-month follow-up. The patency of small arterial branches (intercostal or lumbar arteries) covered by the FloWise were also assessed in the 5 subjects. We attempted FloWise insertion in a total of 32 aneurysm models. FloWise placement was successful in 31 subjects (96.9%). Two stents (6.2%) were occluded at the 3-month follow-up, but there was no evidence of in-stent stenosis in other subjects. All stented aneurysms showed progressive occlusion: grade I (complete aneurysm occlusion) in 44.4% and grade II (aneurysm occlusion > 90%) in 55.6% at 1 month; grade I in 90% and II in 10% at 3 months; and grade I in 90% and II in 10% at 6 months. All small arterial branches covered by the FloWise remained patent. A newly developed, partially retrievable flow-diverter seems to be a safe and effective tool of aneurysm occlusion, as evaluated in the rabbit aneurysm model.

  19. Novel non-contact retina camera for the rat and its application to dynamic retinal vessel analysis

    PubMed Central

    Link, Dietmar; Strohmaier, Clemens; Seifert, Bernd U.; Riemer, Thomas; Reitsamer, Herbert A.; Haueisen, Jens; Vilser, Walthard

    2011-01-01

    We present a novel non-invasive and non-contact system for reflex-free retinal imaging and dynamic retinal vessel analysis in the rat. Theoretical analysis was performed prior to development of the new optical design, taking into account the optical properties of the rat eye and its specific illumination and imaging requirements. A novel optical model of the rat eye was developed for use with standard optical design software, facilitating both sequential and non-sequential modes. A retinal camera for the rat was constructed using standard optical and mechanical components. The addition of a customized illumination unit and existing standard software enabled dynamic vessel analysis. Seven-minute in-vivo vessel diameter recordings performed on 9 Brown-Norway rats showed stable readings. On average, the coefficient of variation was (1.1 ± 0.19) % for the arteries and (0.6 ± 0.08) % for the veins. The slope of the linear regression analysis was (0.56 ± 0.26) % for the arteries and (0.15 ± 0.27) % for the veins. In conclusion, the device can be used in basic studies of retinal vessel behavior. PMID:22076270

  20. Materials and Manufacturing Technologies Available for Production of a Pediatric Bioabsorbable Stent

    PubMed Central

    Alexy, Ryan D.; Levi, Daniel S.

    2013-01-01

    Transcatheter treatment of children with congenital heart disease such as coarctation of the aorta and pulmonary artery stenosis currently involves the use of metal stents. While these provide good short term results, there are long term complications with their use. Children outgrow metal stents, obligating them to future transcatheter dilations and eventual surgical removal. A bioabsorbable stent, or a stent that goes away with time, would solve this problem. Bioabsorbable stents are being developed for use in coronary arteries, however these are too small for use in pediatric congenital heart disease. A bioabsorbable stent for use in pediatric congenital heart disease needs to be low profile, expandable to a diameter 8 mm, provide sufficient radial strength, and absorb quickly enough to allow vessel growth. Development of absorbable coronary stents has led to a great understanding of the available production techniques and materials such as bioabsorbable polymers and biocorrodable metals. Children with congenital heart disease will hopefully soon benefit from the current generation of bioabsorbable and biocorrodable materials and devices. PMID:24089660

  1. Predictors of antegrade flow at internal carotid artery during carotid artery stenting with proximal protection.

    PubMed

    Harada, Kei; Kakumoto, Kosuke; Oshikata, Shogo; Fukuyama, Kozo

    2018-06-01

    Carotid artery stenting (CAS) with proximal occlusion effectively prevent distal cerebral embolism by flow arrest at internal carotid artery (ICA); however, the method can expose antegrade flow at ICA due to incomplete flow arrest. The aim of this study was to identify predictors of antegrade flow during CAS with proximal protection. We retrospectively analyzed clinical and angiographic data among 143 lesions treated with CAS with proximal protection by occluding the common carotid artery (CCA) and external carotid artery (ECA). Flow arrest or antegrade flow at ICA was confirmed by contrast injection during proximal protection. Antegrade flow at ICA was observed in 12 lesions (8.4%). Compared with lesions in which flow arrest of ICA was achieved, the diameter of the superior thyroid artery (STA) was significantly larger (2.4 ± 0.34 vs. 1.4 ± 0.68 mm, p < 0.001), and the rate of ECA branches other than the STA located 0-10 mm above the bifurcation was significantly higher (50 vs. 8.4%, p < 0.001). Results of multivariate analysis revealed that a diameter of the STA ≥ 2.3 mm (OR 44, 95% CI 8.1-237; p < 0.001) and ECA branches other than the STA located 0-10 mm above the bifurcation (OR 6.0, 95% CI 1.1-32; p = 0.036) were independent predictors of antegrade flow. Distal filter protection should be combined with proximal protection for the lesions with antegrade flow to prevent distal migration of the carotid debris.

  2. Intravascular probe for detection of vulnerable plaque

    NASA Astrophysics Data System (ADS)

    Patt, Bradley E.; Iwanczyk, Jan S.; MacDonald, Lawrence R.; Yamaguchi, Yuko; Tull, Carolyn R.; Janecek, Martin; Hoffman, Edward J.; Strauss, H. William; Tsugita, Ross; Ghazarossian, Vartan

    2001-12-01

    Coronary angiography is unable to define the status of the atheroma, and only measures the luminal dimensions of the blood vessel, without providing information about plaque content. Up to 70% of heart attacks are caused by minimally obstructive vulnerable plaques, which are too small to be detected adequately by angiography. We have developed an intravascular imaging detector to identify vulnerable coronary artery plaques. The detector works by sensing beta or conversion electron radiotracer emissions from plaque-binding radiotracers. The device overcomes the technical constraints of size, sensitivity and conformance to the intravascular environment. The detector at the distal end of the catheter uses six 7mm long by 0.5mm diameter scintillation fibers coupled to 1.5m long plastic fibers. The fibers are offset from each other longitudinally by 6mm and arranged spirally around a guide wire in the catheter. At the proximal end of the catheter the optical fibers are coupled to an interface box with a snap on connector. The interface box contains a position sensitive photomultiplier tube (PSPMT) to decode the individual fibers. The whole detector assembly fits into an 8-French (2.7 mm in diameter) catheter. The PSPMT image is further decoded with software to give a linear image, the total instantaneous count rate and an audio output whose tone corresponds to the count rate. The device was tested with F-18 and Tl-204 sources. Spectrometric response, spatial resolution, sensitivity and beta to background ratio were measured. System resolution is 6 mm and the sensitivity is >500 cps / micrometers Ci when the source is 1 mm from the detector. The beta to background ratio was 11.2 for F-18 measured on a single fiber. The current device will lead to a system allowing imaging of labeled vulnerable plaque in coronary arteries. This type of signature is expected to enable targeted and cost effective therapies to prevent acute coronary artery diseases such as: unstable angina, acute myocardial infarction, and sudden cardiac death.

  3. Design and preparation of polyurethane-collagen/heparin-conjugated polycaprolactone double-layer bionic small-diameter vascular graft and its preliminary animal tests.

    PubMed

    Lu, Guang; Cui, Shi-Jun; Geng, Xue; Ye, Lin; Chen, Bing; Feng, Zeng-Guo; Zhang, Jian; Li, Zhong-Zhi

    2013-04-01

    People recently realized that it is important for artificial vascular biodegradable graft to bionically mimic the functions of the native vessel. In order to overcome the high risk of thrombosis and keep the patency in the clinical small-diameter vascular graft (SDVG) transplantation, a double-layer bionic scaffold, which can offer anticoagulation and mechanical strength simultaneously, was designed and fabricated via electrospinning technique. Heparin-conjugated polycaprolactone (hPCL) and polyurethane (PU)-collagen type I composite was used as the inner and outer layers, respectively. The porosity and the burst pressure of SDVG were evaluated. Its biocompatibility was demonstrated by the 3-(4,5-dimethyl-2-thiazol)-2,5-diphenyl-2H tetrazolium bromide (MTT) test in vitro and subcutaneous implants in vivo respectively. The grafts of diameter 2.5 mm and length 4.0 cm were implanted to replace the femoral artery in Beagle dog model. Then, angiography was performed in the Beagle dogs to investigate the patency and aneurysm of grafts at 2, 4, and 8 weeks post-transplantation. After angiography, the patent grafts were explanted for histological analysis. The double-layer bionic SDVG meet the clinical mechanical demand. Its good biocompatibility was proven by cytotoxicity experiment (the cell's relative growth rates (RGR) of PU-collagen outer layer were 102.8%, 109.2% and 103.5%, while the RGR of hPCL inner layer were 99.0%, 100.0% and 98.0%, on days 1, 3, and 5, respectively) and the subdermal implants experiment in the Beagle dog. Arteriography showed that all the implanted SDVGs were patent without any aneurismal dilatation or obvious anastomotic stenosis at the 2nd, 4th, and 8th week after the operation, except one SDVG that failed at the 2nd week. Histological analysis and SEM showed that the inner layer was covered by new endothelial-like cells. The double-layer bionic SDVG is a promising candidate as a replacement of native small-diameter vascular graft.

  4. Friction loss in straight pipes of unplasticized polyvinyl chloride.

    PubMed

    Iwasaki, T; Ojima, J

    1996-01-01

    In order to design proper ductwork for a local exhaust system, airflow characteristics were investigated in straight pipes of unplasticized polyvinyl chloride (PVC). A linear decrease in static pressure was observed downstream at points from the opening of the VU pipes (JIS K 6741) located at distances greater than 10 times the pipe diameter, for velocities ranging between 10.18-36.91 m/s. Roughness inside pipes with small diameters was found to be 0.0042-0.0056 mm and the friction factor was calculated on the basis of Colebrook's equation for an airflow transition zone. An extended friction chart was then constructed on the basis of the roughness value and the friction factor. This chart can be applied when designing a local exhaust system with the ducts of diameters ranging from 40 to 900 mm. The friction loss of the PVC pipe was found to be approximately 2/3 of that of a galvanized steel pipe.

  5. 76 FR 36092 - Small Diameter Graphite Electrodes From the People's Republic of China: Extension of Time Limit...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-21

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-929] Small Diameter Graphite... antidumping duty order on small diameter graphite electrodes from the People's Republic of China (``PRC'') for... preliminary results of this review were published on March 7, 2011. See Small Diameter Graphite Electrodes...

  6. 77 FR 6060 - Small Diameter Graphite Electrodes from the People's Republic of China: Extension of Time Limit...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-07

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-929] Small Diameter Graphite... Department) initiated an administrative review of the antidumping duty order on small diameter graphite... preliminary results of this review by 95 days until February 3, 2012. See Small Diameter Graphite Electrodes...

  7. Composition Based Strategies for Controlling Radii in Lipid Nanotubes

    PubMed Central

    Kurczy, Michael E.; Mellander, Lisa J.; Najafinobar, Neda; Cans, Ann-Sofie

    2014-01-01

    Nature routinely carries out small-scale chemistry within lipid bound cells and organelles. Liposome–lipid nanotube networks are being developed by many researchers in attempt to imitate these membrane enclosed environments, with the goal to perform small-scale chemical studies. These systems are well characterized in terms of the diameter of the giant unilamellar vesicles they are constructed from and the length of the nanotubes connecting them. Here we evaluate two methods based on intrinsic curvature for adjusting the diameter of the nanotube, an aspect of the network that has not previously been controllable. This was done by altering the lipid composition of the network membrane with two different approaches. In the first, the composition of the membrane was altered via lipid incubation of exogenous lipids; either with the addition of the low intrinsic curvature lipid soy phosphatidylcholine (soy-PC) or the high intrinsic curvature lipid soy phosphatidylethanolamine (soy-PE). In the second approach, exogenous lipids were added to the total lipid composition during liposome formation. Here we show that for both lipid augmentation methods, we observed a decrease in nanotube diameter following soy-PE additions but no significant change in size following the addition of soy-PC. Our results demonstrate that the effect of soy-PE on nanotube diameter is independent of the method of addition and suggests that high curvature soy-PE molecules facilitate tube membrane curvature. PMID:24392077

  8. Compliant electrospun silk fibroin tubes for small vessel bypass grafting.

    PubMed

    Marelli, Benedetto; Alessandrino, Antonio; Farè, Silvia; Freddi, Giuliano; Mantovani, Diego; Tanzi, Maria Cristina

    2010-10-01

    Processing silk fibroin (SF) by electrospinning offers a very attractive opportunity for producing three-dimensional nanofibrillar matrices in tubular form, which may be useful for a biomimetic approach to small calibre vessel regeneration. Bypass grafting of small calibre vessels, with a diameter less than 6mm, is performed mainly using autografts, like the saphenous vein or internal mammary artery. At present no polymeric grafts made of SF are commercially available, mainly due to inadequate properties (low compliance and lack of endothelium cells). The aim of this work was to electrospin SF into tubular structures (Ø=6mm) for small calibre vessel grafting, characterize the morphological, chemico-physical and mechanical properties of the electrospun SF structures and to validate their potential to interact with cells. The morphological properties of electrospun SF nanofibres were investigated by scanning electron microscopy. Chemico-physical analyses revealed an increase in the crystallinity of the structure of SF nanofibres on methanol treatment. Mechanical tests, i.e. compliance and burst pressure measurements, of the electrospun SF tubes showed that the inner pressure to radial deformation ratio was linear for elongation up to 15% and pressure up to 400 mm Hg. The mean compliance value between 80 and 120 mm Hg was higher than the values reported for both Goretex(R) and Dacron(R) grafts and for bovine heterografts, but still slightly lower than those of saphenous and umbilical vein, which nowadays represent the gold standard for the replacement of small calibre arteries. The electrospun tubes resisted up to 575+/-17 mmHg, which is more than four times the upper physiological pressure of 120 mmHg and more than twice the pathological upper pressures (range 180-220 mmHg). The in vitro tests showed a good cytocompatibility of the electrospun SF tubes. Therefore, the electrospun SF tubes developed within this work represent a suitable candidate for small calibre blood vessel replacement. 2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  9. The proximally based long peroneal muscle turnover flap: A novel salvage flap for small to medium-sized defects of the knee.

    PubMed

    Wagner, Till; Hupkens, Pieter; Slater, Nicholas J; Ulrich, Dietmar J O

    2016-04-01

    Coverage of soft-tissue defects of the knee due to multiple operations, trauma, and infection remains a surgical challenge. Often, these defects are repaired using free tissue transfer. The aim of this study was to find an easy and reliable local method of repair for small to medium-sized defects. The authors describe a new surgical option for tissue coverage using a proximally based long peroneal muscle turnover flap (LPTF) with split-thickness skin graft. Proximally based LPTFs were harvested and transposed into same-size created defects in five cadavers. After optimizing this technique, it was clinically used in two patients with defects secondary to total knee replacement revisions. Average cadaver flap size was 4.7 × 15.8 cm allowing reach of all knee joint areas and was based consistently on a sufficient (2-mm-diameter average) proximal arterial branch of the anterior tibial artery. Donor sites were closed without tension. Subsequent application of the flap on two patients resulted in good functional outcome. The proximally based LPTF is a new option available in the reconstruction of knee defects and should be added to the reconstructive surgeon's armamentarium of pedicled flaps, providing short operating time and promising clinical outcome. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Estimation of inlet flow rates for image-based aneurysm CFD models: where and how to begin?

    PubMed

    Valen-Sendstad, Kristian; Piccinelli, Marina; KrishnankuttyRema, Resmi; Steinman, David A

    2015-06-01

    Patient-specific flow rates are rarely available for image-based computational fluid dynamics models. Instead, flow rates are often assumed to scale according to the diameters of the arteries of interest. Our goal was to determine how choice of inlet location and scaling law affect such model-based estimation of inflow rates. We focused on 37 internal carotid artery (ICA) aneurysm cases from the Aneurisk cohort. An average ICA flow rate of 245 mL min(-1) was assumed from the literature, and then rescaled for each case according to its inlet diameter squared (assuming a fixed velocity) or cubed (assuming a fixed wall shear stress). Scaling was based on diameters measured at various consistent anatomical locations along the models. Choice of location introduced a modest 17% average uncertainty in model-based flow rate, but within individual cases estimated flow rates could vary by >100 mL min(-1). A square law was found to be more consistent with physiological flow rates than a cube law. Although impact of parent artery truncation on downstream flow patterns is well studied, our study highlights a more insidious and potentially equal impact of truncation site and scaling law on the uncertainty of assumed inlet flow rates and thus, potentially, downstream flow patterns.

  11. Coronary veins determine the pattern of sympathetic innervation in the developing heart

    PubMed Central

    Nam, Joseph; Onitsuka, Izumi; Hatch, John; Uchida, Yutaka; Ray, Saugata; Huang, Siyi; Li, Wenling; Zang, Heesuk; Ruiz-Lozano, Pilar; Mukouyama, Yoh-suke

    2013-01-01

    Anatomical congruence of peripheral nerves and blood vessels is well recognized in a variety of tissues. Their physical proximity and similar branching patterns suggest that the development of these networks might be a coordinated process. Here we show that large diameter coronary veins serve as an intermediate template for distal sympathetic axon extension in the subepicardial layer of the dorsal ventricular wall of the developing mouse heart. Vascular smooth muscle cells (VSMCs) associate with large diameter veins during angiogenesis. In vivo and in vitro experiments demonstrate that these cells mediate extension of sympathetic axons via nerve growth factor (NGF). This association enables topological targeting of axons to final targets such as large diameter coronary arteries in the deeper myocardial layer. As axons extend along veins, arterial VSMCs begin to secrete NGF, which allows axons to reach target cells. We propose a sequential mechanism in which initial axon extension in the subepicardium is governed by transient NGF expression by VSMCs as they are recruited to coronary veins; subsequently, VSMCs in the myocardium begin to express NGF as they are recruited by remodeling arteries, attracting axons toward their final targets. The proposed mechanism underlies a distinct, stereotypical pattern of autonomic innervation that is adapted to the complex tissue structure and physiology of the heart. PMID:23462468

  12. Retinal artery-vein classification via topology estimation

    PubMed Central

    Estrada, Rolando; Allingham, Michael J.; Mettu, Priyatham S.; Cousins, Scott W.; Tomasi, Carlo; Farsiu, Sina

    2015-01-01

    We propose a novel, graph-theoretic framework for distinguishing arteries from veins in a fundus image. We make use of the underlying vessel topology to better classify small and midsized vessels. We extend our previously proposed tree topology estimation framework by incorporating expert, domain-specific features to construct a simple, yet powerful global likelihood model. We efficiently maximize this model by iteratively exploring the space of possible solutions consistent with the projected vessels. We tested our method on four retinal datasets and achieved classification accuracies of 91.0%, 93.5%, 91.7%, and 90.9%, outperforming existing methods. Our results show the effectiveness of our approach, which is capable of analyzing the entire vasculature, including peripheral vessels, in wide field-of-view fundus photographs. This topology-based method is a potentially important tool for diagnosing diseases with retinal vascular manifestation. PMID:26068204

  13. Heterogeneity in relaxation of different sized porcine coronary arteries to nitrovasodilators: role of PKG and MYPT1.

    PubMed

    Ying, Lei; Xu, Xiaojian; Liu, Juan; Dou, Dou; Yu, Xiaoxing; Ye, Liping; He, Qiong; Gao, Yuansheng

    2012-02-01

    The present study was to determine the role of the type I isoform of cGMP-dependent protein kinase (PKG I) and its downstream effector myosin phosphatase target subunit 1 (MYPT1) in the responses of different sized coronary arteries to nitrovasodilators. Relaxations of isolated porcine coronary arteries were determined by isometric tension recording technique. Protein levels of PKG I and its effectors were analyzed by Western blotting. The activities of PKG I and MYPT1 were studied by analyzing phosphorylation of vasodilator-stimulated phosphoprotein (VASP) and MYPT1, respectively. Nitroglycerin, DETA NONOate, and 8-Br-cGMP caused greater relaxations in large than in small coronary arteries. Relaxations were attenuated to a greater extent by Rp-8-Br-PET-cGMPS (a PKG inhibitor) in large vs. small arteries. The expressions of PKG I and MYPT1 in large arteries were more abundant than in small arteries. DETA NONOate stimulated phosphorylation of VASP at Ser239 and inhibited phosphorylation of MYPT1 at Thr853 to a greater extent in large than in small arteries. A suppressed phosphorylation of MYPT1 at Thr853 was caused by 8-Br-cGMP in large but not small arteries, which was inhibited by Rp-8-Br-PET-cGMPS. These results suggest that the greater responsiveness of large coronary arteries to nitrovasodilators result in part from greater activities of PKG I and MYPT1. Dysfunction in nitric oxide signaling is implicated in the vulnerability of large coronary arteries to certain disorders such as atherosclerosis and spasm. Augmentation of PKG I-MYPT1 signaling may be of therapeutic benefit for combating these events.

  14. Renal sympathetic denervation increases renal blood volume per cardiac cycle: a serial magnetic resonance imaging study in resistant hypertension.

    PubMed

    Delacroix, Sinny; Chokka, Ramesh G; Nelson, Adam J; Wong, Dennis T; Sidharta, Samuel; Pederson, Stephen M; Rajwani, Adil; Nimmo, Joanne; Teo, Karen S; Worthley, Stephen G

    2017-01-01

    Preclinical studies have demonstrated improvements in renal blood flow after renal sympathetic denervation (RSDN); however, such effects are yet to be confirmed in patients with resistant hypertension. Herein, we assessed the effects of RSDN on renal artery blood flow and diameter at multiple time points post-RSDN. Patients (n=11) with systolic blood pressures ≥160 mmHg despite taking three or more antihypertensive medications at maximum tolerated dose were recruited into this single-center, prospective, non-blinded study. Magnetic resonance imaging indices included renal blood flow and renal artery diameters at baseline, 1 month and 6 months. In addition to significant decreases in blood pressures ( p <0.0001), total volume of blood flow per cardiac cycle increased by 20% from 6.9±2 mL at baseline to 8.4±2 mL ( p =0.003) at 1 month and to 8.0±2 mL ( p =0.04) 6 months post-procedure, with no changes in the renal blood flow. There was a significant decrease in renal artery diameters from 7±2 mm at baseline to 6±1 mm ( p =0.03) at 1 month post-procedure. This decrease was associated with increases in maximum velocity of blood flow from 73±20 cm/s at baseline to 78±19 cm/s at 1 month post-procedure. Notably, both parameters reverted to 7±2 mm and 72±18 cm/s, respectively, 6 months after procedure. RSDN improves renal physiology as evidenced by significant improvements in total volume of blood flow per cardiac cycle. Additionally, for the first time, we identified a transient decrease in renal artery diameters immediately after procedure potentially caused by edema and inflammation that reverted to baseline values 6 months post-procedure.

  15. Comparative characterization of stromal vascular cells derived from three types of vascular wall and adipose tissue.

    PubMed

    Yang, Santsun; Eto, Hitomi; Kato, Harunosuke; Doi, Kentaro; Kuno, Shinichiro; Kinoshita, Kahori; Ma, Hsu; Tsai, Chi-Han; Chou, Wan-Ting; Yoshimura, Kotaro

    2013-12-01

    Multipotent stem/progenitor cells localize perivascularly in many organs and vessel walls. These tissue-resident stem/progenitor cells differentiate into vascular endothelial cells, pericytes, and other mesenchymal lineages, and participate in physiological maintenance and repair of vasculatures. In this study, we characterized stromal vascular cells obtained through the explant culture method from three different vessel walls in humans: arterial wall (ART; >500 μm in diameter), venous wall (VN; >500 μm in diameter), and small vessels in adipose tissue (SV; arterioles and venules, <100 μm in diameter). These were examined for functionality and compared with adipose-derived stem/stromal cells (ASCs). All stromal vascular cells of different origins presented fibroblast-like morphology and we could not visually discriminate one population from another. Flow cytometry showed that the cultured population heterogeneously expressed a variety of surface antigens associated with stem/progenitor cells, but CD105 was expressed by most cells in all groups, suggesting that the cells generally shared the characteristics of mesenchymal stem cells. Our histological and flow cytometric data suggested that the main population of vessel wall-derived stromal vascular cells were CD34(+)/CD31(-) and came from the tunica adventitia and areola tissue surrounding the adventitia. CD271 (p75NTR) was expressed by the vasa vasorum in the VN adventitia and by a limited population in the adventitia of SV. All three populations differentiated into multiple lineages as did ASCs. ART cells induced the largest quantity of calcium formation in the osteogenic medium, whereas ASCs showed the greatest adipogenic differentiation. SV and VN stromal cells had greater potency for network formation than did ART stromal cells. In conclusion, the three stromal vascular populations exhibited differential functional properties. Our results have clinical implications for vascular diseases such as arterial wall calcification and possible applications to regenerative therapies involving each vessel wall-resident stromal population.

  16. Change in Elasticity Caused by Flow-Mediated Dilation Measured Only for Intima-Media Region of Brachial Artery

    NASA Astrophysics Data System (ADS)

    Sugimoto, Masataka; Hasegawa, Hideyuki; Kanai, Hiroshi

    2005-08-01

    Endothelial dysfunction is considered to be an initial step of arteriosclerosis [R. Ross: N. Engl. J. Med. 340 (2004) 115]. For the assessment of the endothelium function, brachial artery flow-mediated dilation (FMD) caused by increased blood flow has been evaluated with ultrasonic diagnostic equipment. In the case of conventional methods, the change in artery diameter caused by FMD is measured [M. Hashimoto et al.: Circulation 92 (1995) 3431]. Although the arterial wall has a layered structure (intima, media, and adventitia), such a structure is not taken into account in conventional methods because the change in diameter depends on the characteristic of the entire wall. However, smooth muscle present only in the media contributes to FMD, whereas the collagen-rich hard adventitia does not contribute. In this study, we measure the change in elasticity of only the intima-media region including smooth muscle using the phased tracking method [H. Kanai et al.: IEEE Trans. Ultrason. Ferroelectr. Freq. Control 43 (1996) 791]. From the change in elasticity, FMD measured only for the intima-media region by our proposed method was found to be more sensitive than that measured for the entire wall by the conventional method.

  17. Temporary morphological changes in plus disease induced during contact digital imaging

    PubMed Central

    Zepeda-Romero, L C; Martinez-Perez, M E; Ruiz-Velasco, S; Ramirez-Ortiz, M A; Gutierrez-Padilla, J A

    2011-01-01

    Objective To compare and quantify the retinal vascular changes induced by non-intentional pressure contact by digital handheld camera during retinopathy of prematurity (ROP) imaging by means of a computer-based image analysis system, Retinal Image multiScale Analysis. Methods A set of 10 wide-angle retinal pairs of photographs per patient, who underwent routine ROP examinations, was measured. Vascular trees were matched between ‘compression artifact' (absence of the vascular column at the optic nerve) and ‘not compression artifact' conditions. Parameters were analyzed using a two-level linear model for each individual parameter for arterioles and venules separately: integrated curvature (IC), diameter (d), and tortuosity index (TI). Results Images affected with compression artifact showed significant vascular d (P<0.01) changes in both arteries and veins, as well as in artery IC (P<0.05). Vascular TI remained unchanged in both groups. Conclusions Non-adverted corneal pressure with the RetCam lens could compress and decrease intra-arterial diameter or even collapse retinal vessels. Careful attention to technique is essential to avoid absence of the arterial blood column at the optic nerve head that is indicative of increased pressure during imaging. PMID:21760627

  18. [Morphometrical analyze of the middle cerebral artery system at the 13-15 weeks fetuses].

    PubMed

    Macovei, Georgeta Nataşa; Varlam, H; St Antohe, D

    2002-01-01

    Tele-encephalization process is accompanied by the appearance and progressive complication of the middle cerebral artery system. The aim of our study is to analyze the morphometrical parameters of the middle cerebral artery branches in the beginning of the edification of its system. We used 162 cerebral hemispheres from 88 fetuses aged of 13-15 weeks. Middle cerebral artery system was injected with a gelatin-China ink mixture and images recorded by means of a Zeiss surgical microscope. Parameters evaluation (length, proximal and distal diameters, external surface, volume, angles of bifurcation) was realized with KS-300 program. At this early age middle cerebral artery system has only 4-5 generations of branches usually resulting from acute angle bifurcations.

  19. Building America Case Study: Standard- Versus High-Velocity Air Distribution in High-Performance Townhomes, Denver, Colorado

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    A. Poerschke, R. Beach, T. Begg

    IBACOS investigated the performance of a small-diameter high-velocity heat pump system compared to a conventional system in a new construction triplex townhouse. A ductless heat pump system also was installed for comparison, but the homebuyer backed out because of aesthetic concerns about that system. In total, two buildings, having identical solar orientation and comprised of six townhomes, were monitored for comfort and energy performance.

  20. Association Between Vascular Anatomy and Posterior Communicating Artery Aneurysms.

    PubMed

    Can, Anil; Ho, Allen L; Emmer, Bart J; Dammers, Ruben; Dirven, Clemens M F; Du, Rose

    2015-11-01

    Hemodynamic stress, conditioned by the geometry and morphology of the vessel trees, plays an important role in the formation of intracranial aneurysms. The aim of this study was to identify image-based location-specific morphologic parameters that are associated with posterior communicating artery (PCoA) aneurysms. Morphologic parameters obtained from computed tomography angiography of 56 patients with PCoA aneurysms and 23 control patients were evaluated with 3D Slicer, an open-source image analysis software, to generate 3-dimensional models of the aneurysms and surrounding vasculature. Segment lengths, diameters, and vessel-to-vessel angles were examined. To control for genetic and clinical risk factors, the unaffected contralateral side of patients with unilateral PCoA aneurysms was used as a control group for internal carotid artery (ICA)-related parameters. A separate control group with visible PCoAs and aneurysms elsewhere was used as a control group for PCoA-related parameters. Internal carotid artery-related parameters were not statistically different between the PCoA aneurysm and control groups. Univariate and multivariate subgroup analysis for patients with visualized PCoAs demonstrated that a larger PCoA diameter was significantly associated with the presence of a PCoA aneurysm (odds ratio = 12.1, 95% confidence interval = 1.3-17.1, P = 0.04) after adjusting for other morphologic parameters. Larger PCoA diameters are associated with the presence of PCoA aneurysms. These parameters may provide objective metrics to assess aneurysm formation and growth risk stratification in high-risk patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. [Classification of cerebrovascular processes using ultrasound methods].

    PubMed

    Klein, K

    1984-01-01

    By means of ultrasound A-mode echography and Doppler-Kranzbühler sonography new fundamentals of non-invasive qualitative and quantitative classification of cerebrovascular processes could be developed: Apart from usual screening of stenoses and pulse curve analyses, measurements of diameters and wall movements in the extracranial and intracranial carotid artery and in the vertebral artery as well as determinations of the systolic and diastolic flow velocities in the extracranial arteries are outstanding features. By recording and evaluating these parameters and data patterns, coupled with clinical findings, differential conclusions on reactions of the cerebral hemodynamics in macrocirculatory and microcirculatory regions were realized in geriatric patients under the following pathophysiological and therapeutically induced conditions: Generally and regionally accentuated arteriosclerotic lesions of the brain (predominant vertebrobasilar insufficiency), decrease of flow velocities according to the diameter, aggravation by distress; principal possibility of pharmacological influence if myogenic autoregulation function is rehabilitable: It is demonstrated by the example of a long-term therapy with a combination of Raubasine, Dihydroergocristine and DHE (Defluina forte).

  2. Resliced image space construction for coronary artery collagen fibers.

    PubMed

    Luo, Tong; Chen, Huan; Kassab, Ghassan S

    2017-01-01

    Collagen fibers play an important role in the biomechanics of the blood vessel wall. The objective of this study was to determine the 3D microstructure of collagen fibers in the media and adventitia of coronary arteries. We present a novel optimal angle consistence algorithm to reform image slices in the visualization and analysis of 3D collagen images. 3D geometry was reconstructed from resliced image space where the 3D skeleton was extracted as the primary feature for accurate reconstruction of geometrical parameters. Collagen fibers (range 80-200) were reconstructed from the porcine coronary artery wall for the measurement of various morphological parameters. Collagen waviness and diameters were 1.37 ± 0.19 and 2.61 ± 0.89 μm, respectively. The biaxial distributions of orientation had two different peaks at 110.7 ± 25.2° and 18.4 ± 19.3°. Results for width, waviness, and orientation were found to be in good agreement with manual measurements. In addition to accurately measuring 2D features more efficiently than the manual approach, the present method produced 3D features that could not be measured in the 2D manual approach. These additional parameters included the tilt angle (5.10 ± 2.95°) and cross-sectional area (CSA; 5.98 ± 3.79 μm2) of collagen fibers. These 3D collagen reconstructions provide accurate and reliable microstructure for biomechanical modeling of vessel wall mechanics.

  3. Small volcanic edifices and volcanism in the plains of Venus

    NASA Technical Reports Server (NTRS)

    Guest, John E.; Bulmer, Mark H.; Aubele, Jayne; Beratan, Kathi; Greeley, Ronald; Head, James W.; Michaels, Gregory; Weitz, Catherine; Wiles, Charles

    1992-01-01

    The different types of eruption that have occurred over time in the Venusian plains are considered. The most extensive volcanic units consist of flood lavas, the largest of which have volumes of the order of thousands of cubic kilometers. They are inferred to have erupted at high effusion rates, and they exhibit a range of radar backscatter characteristics indicating different surface textures and ages. Small edifices on the plains occur mainly in clusters associated with fracture belts. The majority are shield volcanos that may be up to a few tens of kilometers across but are generally 10 km or less in diameter. Volcanic domes have diameters up to several tens of kilometers and volumes of the order of 100 cu cm. These are interpreted as being constructed of lava erupted with a relatively high effective viscosity and thus possibly composed of more silicic lava. For many domes, the flanks were unstable during and after eruption and experienced gravity sliding that produced steep scalloped outer margins.

  4. The Amplatz canine duct occluder: a novel device for patent ductus arteriosus occlusion.

    PubMed

    Nguyenba, Thaibinh P; Tobias, Anthony H

    2007-11-01

    The Amplatz canine duct occluder (ACDO) is a nitinol mesh device with a short waist that separates a flat distal disc from a cupped proximal disc. The device is designed to conform to the morphology of the canine patent ductus arteriosus (PDA). PDA dimensions are determined by angiography, and a guiding catheter is advanced into the main pulmonary artery via the aorta and PDA. An ACDO with a waist diameter approximately twice the angiographic minimal ductal diameter (MDD) is advanced via the catheter using an attached delivery cable until the flat distal disc deploys within the main pulmonary artery. The partially deployed ACDO, guiding catheter, and delivery cable are retracted until the distal disc engages the pulmonic ostium of the PDA. With the delivery cable stabilized, the catheter is retracted to deploy the waist across the pulmonic ostium and cupped proximal disc within the ductal ampulla. Tension on the delivery cable is released, and correct ACDO positioning and stability are confirmed by observing that the device assumes its native shape, back-and-forth maneuvering of the delivery cable, and a small contrast injection made through the guiding catheter. The delivery cable is detached and removed with the guiding catheter. To assess for any residual ductal flow, an angiogram is performed at the conclusion of the procedure, followed by Doppler echocardiography at 1 day and 3 months post-procedure. PDA occlusion in dogs with the ACDO is straightforward and extremely effective across a wide range of body weights, somatotypes, MDDs, and ductal morphologies.

  5. Criteria for determining the need for surgical treatment of tricuspid regurgitation during mitral valve replacement

    PubMed Central

    2012-01-01

    Background Tricuspid regurgitation (TR) is common in patients with mitral valve disease; however, there are no straightforward, rapidly determinably criteria available for deciding whether TR repair should be performed during mitral valve replacement. The aim of our retrospective study was to identify a simple and fast criterion for determining whether TR repair should be performed in patients undergoing mitral valve replacement. Methods We reviewed the records of patients who underwent mitral valve replacement with or without (control) TR repair (DeVega or Kay procedure) from January 2005 to December 2008. Preoperative and 2-year postoperative echocardiographic measurements included right ventricular and atrial diameter, interventricular septum size, TR severity, ejection fraction, and pulmonary artery pressure. Results A total of 89 patients were included (control, n = 50; DeVega, n = 27; Kay, n = 12). Demographic and clinical characteristics were similar between groups. Cardiac variables were similar between the DeVega and Kay groups. Right atrium and ventricular diameter and ejection fraction were significantly decreased postoperatively both in the control and operation (DeVega + Kay) group (P < 0.05). Pulmonary artery pressure was significantly decreased postoperatively in-operation groups (P < 0.05). Our findings indicate that surgical intervention for TR should be considered during mitral valve replacement if any of the following preoperative criteria are met: right atrial transverse diameter > 57 mm; right ventricular end-diastolic diameter > 55 mm; pulmonary artery pressure > 58 mmHg. Conclusions Our findings suggest echocardiography may be used as a rapid and simple means of determining which patients require TR repair during mitral valve replacement. PMID:22443513

  6. Transcatheter Coil Embolization of Splenic Artery Aneurysm

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamamoto, Satoshi, E-mail: s-yama@hyo-med.ac.jp; Hirota, Shozo; Maeda, Hiroaki

    2008-05-15

    The purpose of this study was to evaluate clinical results and technical problems of transcatheter coil embolization for splenic artery aneurysm. Subjects were 16 patients (8 men, 8 women; age range, 40-80 years) who underwent transcatheter embolization for splenic artery aneurysm (14 true aneurysms, 2 false aneurysms) at one of our hospitals during the period January 1997 through July 2005. Two aneurysms (12.5%) were diagnosed at the time of rupture. Multiple splenic aneurysms were found in seven patients. Aneurysms were classified by site as proximal (or strictly ostial) (n = 3), middle (n = 3), or hilar (n = 10).more » The indication for transcatheter arterial embolization was a false or true aneurysm 20 mm in diameter. Embolic materials were fibered coils and interlocking detachable coils. Embolization was performed by the isolation technique, the packing technique, or both. Technically, all aneurysms were devascularized without severe complications. Embolized aneurysms were 6-40 mm in diameter (mean, 25 mm). Overall, the primary technical success rate was 88% (14 of 16 patients). In the remaining 2 patients (12.5%), partial recanalization occurred, and re-embolization was performed. The secondary technical success rate was 100%. Seven (44%) of the 16 study patients suffered partial splenic infarction. Intrasplenic branching originating from the aneurysm was observed in five patients. We conclude that transcatheter coil embolization should be the initial treatment of choice for splenic artery aneurysm.« less

  7. DNS of flow in stenosed carotid artery

    NASA Astrophysics Data System (ADS)

    Grinberg, Leopold; Yakhot, Alexander; Karniadakis, George

    2006-11-01

    Direct numerical simulation (DNS) of a three-dimensional flow through a stenosed carotid artery has been performed. Onset of turbulence downstream of the occlusion has been observed. The developing turbulence is characterized by an alternating spatio-temporal transitional regime. The transition to turbulence occurs during the systolic phase approximately five throat-diameters downstream of the throat, while laminarization occurs during the diastolic phase. Transition in space is first enhanced and subsequently decays downstream. The wall shear stress increases in the stenosed internal carotid artery due to the vessel occlusion and as the result of turbulence.

  8. THE SECOND BLIND SPOT: SMALL RETINAL VESSEL VASCULOPATHY AFTER VACCINATION AGAINST NEISSERIA MENINGITIDIS AND YELLOW FEVER.

    PubMed

    Moysidis, Stavros N; Koulisis, Nicole; Patel, Vivek R; Kashani, Amir H; Rao, Narsing A; Humayun, Mark S; Rodger, Damien C

    2017-01-01

    To describe a case of small retinal vessel vasculopathy postvaccination. We report the case of a 41-year-old white man who presented with a "second blind spot," describing a nasal scotoma in the right eye that started 4 days after vaccinations against Neisseria meningitidis and the yellow fever virus, and after a 2-month period of high stress and decreased sleep. Clinical examination, Humphrey visual field testing, and multimodal imaging with fundus photographs, autofluorescence, fluorescein angiography, and spectral domain optical coherence tomography and angiography were performed. Clinical examination revealed a well-circumscribed, triangular area of retinal graying of about 1-disk diameter in size, located at the border of the temporal macula. This corresponded to a deep scotoma similar in size to the physiologic blind spot on Humphrey visual field 24-2 testing. There was mild hypoautofluoresence of this lesion on autofluorescence, hypofluorescence on fluorescein angiography, and focal attenuation of a small artery just distal to the bifurcation of an artery supplying the involved area. Spectral domain optical coherence tomography through the lesion conveyed hyperreflectivity most prominent in the inner and outer plexiform layers, with extension of the hyperreflectivity into the ganglion cell and inner nuclear layers. Spectral domain optical coherence tomography angiography demonstrated arteriolar and capillary dropout, more pronounced in the superficial retinal layer compared to the deeper retinal layer. At 1-month follow-up, his scotoma improved with monitoring, with reduction from -32 dB to -7 dB on Humphrey visual field testing. There was clinical resolution of the area of graying and decreased hyperreflectivity on spectral domain optical coherence tomography, with atrophy of the inner retina. Spectral domain optical coherence tomography angiography showed progression of arteriolar and capillary dropout, more so in the superficial than in the deep capillary plexus. We describe a case of small artery occlusion in a previously healthy patient, 4 days after vaccination against N. meningitidis and yellow fever. Fluorescein angiography yielded greater diagnostic value than OCTA for evaluating the occlusion, whereas spectral domain optical coherence tomography angiography enabled better visualization of capillary dropout and layer-specific assessment. Further research is required to determine whether vaccination in general, or directed specifically at N. meningitidis or yellow fever, is associated with small vessel vasculopathy and the underlying pathogenesis.

  9. T-Stenting-and-Small-Protrusion Technique for Bifurcation Stenoses After End-to-Side Anastomosis of Transplant Renal Artery and External Iliac Artery: Report of Two Cases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Yong, E-mail: cheny102@163.com; Ye, Peng, E-mail: thomas19871223@163.com; Jiang, Wen-jin, E-mail: 18653501187@163.com

    Bifurcation stenoses after end-to-side anastomosis of transplant renal artery (TRA) and external iliac artery (EIA), including stenoses at the anastomosis and the iliac artery proximal to the TRA, are rare. In the present article, we report two successfully managed cases of bifurcation stenoses after end-to-side anastomosis of the TRA and EIA using the technique of T-stenting and small protrusion (TAP stenting)

  10. Basic investigation of vascular interventional radiology (IR) using large rabbits.

    PubMed

    Nitta, Norihisa; Sonoda, Akinaga; Nitta-Seko, Ayumi; Ohta, Shinichi; Tsuchiya, Keiko; Tanaka, Toyohiko; Kanasaki, Shuzo; Mukaisho, Kenichi; Takahashi, Masashi; Murata, Kiyoshi

    2009-10-01

    The purpose of this study was to determine the usefulness of large rabbits for basic vascular interventional radiology (IR) experiments. We used 5 Akita large rabbits (Akita) and 5 Japanese white rabbits (JW). We conducted measurements of vessel diameters such as the aorta, and the iliac, renal, superior mesenteric, celiac, and proper hepatic arteries, and of the growth rates of VX2 liver tumors. There were significant differences between Akita and JW in the diameters of the thoracic aorta, lower abdominal aorta, and celiac artery. In other blood vessels, no significant differences were found. There was no difference in the growth rates of the VX2 tumors between Akita and JW. The possibility that Akita large rabbits could be utilized for vascular IR was demonstrated.

  11. Design and construction of driven pile foundations--lessons learned on the Central Artery/Tunnel project

    DOT National Transportation Integrated Search

    2006-06-01

    Five contracts from the Central Artery/Tunnel (CA/T) project in Boston, MA, were reviewed to document issues related to design and construction of driven pile foundations. Given the soft and compressible marine clays in the Boston area, driven pile f...

  12. Pulse Pressure and Carotid Artery Doppler Velocimetry as Indicators of Maternal Volume Status: A Prospective Cohort Study.

    PubMed

    Lappen, Justin R; Myers, Stephen A; Bolden, Norman; Shaman, Ziad; Angirekula, Venkata; Chien, Edward K

    2018-03-01

    Narrow pulse pressure has been demonstrated to indicate low central volume status. In critically ill patients, volume status can be qualitatively evaluated using Doppler velocimetry to assess hemodynamic changes in the carotid artery in response to autotransfusion with passive leg raise (PLR). Neither parameter has been prospectively evaluated in an obstetric population. The objective of this study was to determine if pulse pressure could predict the response to autotransfusion using carotid artery Doppler in healthy intrapartum women. We hypothesized that the carotid artery Doppler response to PLR would be greater in women with a narrow pulse pressure, indicating relative hypovolemia. Intrapartum women with singleton gestations ≥35 weeks without acute or chronic medical conditions were recruited to this prospective cohort study. Participants were grouped by admission pulse pressure as <45 mm Hg(narrow) or ≥50 mm Hg(normal). Maternal carotid artery Doppler assessment was then performed in all patients before and after PLR using a standard technique where carotid blood flow (mL/min) = π × (carotid artery diameter/2) × (velocity time integral) x (60 seconds). The velocity time integral was calculated from the Doppler waveform. The primary outcome was the change in the carotid Doppler parameters (carotid artery diameter, velocity time integral, and carotid blood flow) after PLR. Outcomes were compared between study groups with univariable and multivariable analyses with adjustment for potential confounding factors. Thirty-three women consented to participation, including 18 in the narrow and 15 in the normal pulse pressure groups (mean and standard deviation initial pulse pressure, 38.3 ± 4.4 vs 57.3 ± 4.1 mm Hg). The 2 groups demonstrated similar characteristics except for initial pulse pressure, systolic and diastolic blood pressure, and race. In response to PLR, the narrow pulse pressure group had a significantly greater increase in carotid artery diameter (0.08 vs 0.02 cm; standardized difference, 2.0; 95% confidence interval [CI], 1.16-2.84), carotid blood flow (79.4 vs 16.0 mL/min; standardized difference, 2.23; 95% CI, 1.36-3.10), and percent change in carotid blood flow (47.5% vs 8.7%; standardized difference, 2.52; 95% CI, 1.60-3.43) compared with the normal pulse pressure group. In multivariable analysis with adjustment for potential confounding factors, women with narrow admission pulse pressure had a significantly larger carotid diameter (0.66 vs 0.62 cm; P < .0001) and greater carotid flow (246.7 vs 219.3 cm/s; P = .001) after PLR compared to women with a normal pulse pressure. Initial pulse pressure was strongly correlated with the change in carotid flow after PLR (r2 = 0.60; P < .0001). The hemodynamic response of the carotid artery to autotransfusion after PLR is significantly greater in women with narrow pulse pressure. Pulse pressure correlates with the physiological response to autotransfusion and provides a qualitative indication of intravascular volume in term and near-term pregnant women.

  13. Arterial supply of human and bovine testes: a topographic and morphometric comparison study.

    PubMed

    Polguj, M; Jędrzejewski, K S; Topol, M

    2010-11-01

    The aim of the study was to compare the arteries supplying human and bovine masculine gonads. The study was made on two extremely different types of location of the mediastinum testis. The study was made on 100 (50 human and 50 bovine) corrosive casts of the testicular, cremasteric, and deference duct arteries. The differences between the species included different courses of the testicular artery inside the spermatic duct, the relative size of the three arterial diameters, and the morphology of the anastomoses of the arteries. In human testicular arteries, the course inside the spermatic course was more variable than in that of bulls. The artery was straighter and in 80% of the cases did not form the loops which were present in 100% of the bovine specimens. The bovine testicular artery was significantly wider in relation to the cremasteric and deferens duct arteries than the human one. This finding suggests that collateral blood flow to the testis was less effective in bulls than in men. The human testicular artery directly connected the other two with its terminal branches. The bovine testicular artery connected with the cremasteric and deferens duct arteries indirectly by means of its deferens duct branch.

  14. The posterior communicating artery: morphometric study in 3D angio-computed tomography reconstruction. The proof of the mathematical definition of the hypoplasia.

    PubMed

    Dzierżanowski, J; Szarmach, A; Słoniewski, P; Czapiewski, P; Piskunowicz, M; Bandurski, T; Szmuda, T

    2014-08-01

    The aim of this study was to investigate the morphometry of the posterior communicating artery (PCoA), on the basis of angio-computed tomography (CT), and to give proof of the mathematical definition of the term "hypopal sia of the PCoA". One hundred 3-dimensional (3D) angio-CT images, performed in adult patients with bilateral reconstruction of the PCoA (200 results) were used tocalculate the morphometry of the vessel. The average length of the vessel on the right side was 14.48 ± 3.47 mm, andon the left side 14.98 ± 4.77 mm (in women 14.75 mm, in men 14.70 mm). The mean of the diameter at the "proximal" point (the junction with P1) on the right side was 1.49 ± 0.51 mm, and on the left 1.46 ± 0.47 mm (in women 1.44 mm and in men 1.51 mm). The mean of the diameter in the "distal" part (the connection with ICA) on the right side was 1.4 ± 0.49 mm, and on the left 1.37 ± 0.41 mm (in women 1.38 mm, and in men 1.39 mm). No statistical correlation between the length and the diameter of the PCoA in relation to the sex and side was shown. On the basis of our measurements, we defined the hypoplasia of the artery as the estimated value less than the average diameter minus the standard deviation. The percentage distribution was as follows: the left artery 15.5%, the right artery 24%, women 11.5%, and the men 9%. Similarly to the above parameters, we have not found any statistical differences. The presence of the foetal origin was noted in 25% of the radiological examinations. The infundibular widening was visualised in 11.5% of cases of 3D reconstructions. The agenesis of PCoA was found in 9% (never bilaterally), and in 1 case the unilateral duplication of the artery was observed. No statistical differences between those parameters in relation to sex and the examined side were revealed. Morphological calculation of the PCoA on the basis of angio-CT from adult patients did not show any statistical differences depending on sex or the investigated side. The presented method of the calculations proved to be useful for the mathematical definition of the term "hypoplasia of the PCoA".

  15. Experimentally determined transport and magnetization ac losses of small cable models constructed from YBCO coated conductors

    NASA Astrophysics Data System (ADS)

    Šouc, J.; Vojenčiak, M.; Gömöry, F.

    2010-04-01

    Several short cable models were constructed from YBCO coated conductor (YBCO CC) to study their basic dc and ac electrical properties. They were prepared using superconducting tapes helically wound on fiberglass former of different diameter (5, 8 and 10 mm) with different twist pitch (from 1.7 up to 2.4 cm). The number of parallel-connected tapes ranged from 1 up to 6. The standard length of the models was 11 cm. In one case a 35 cm long model has been manufactured in order to perform a bending test. We observed that the critical currents of the models were proportional to the number of tapes used for their construction. Transport and magnetization ac loss were measured at 36 and 72 Hz.

  16. Production of Monodisperse Cerium Oxide Microspheres with Diameters near 100 µm by Internal-Gelation Sol-Gel Methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katalenich, Jeffrey A.; Kitchen, Brian B.; Pierson, Bruce

    Cerium dioxide microspheres with uniform diameters between 65 – 211 µm were fabricated using internal gelation sol-gel methods. Although uniform microspheres are produced for nuclear fuel applications with diameters above 300 µm, sol-gel microspheres with diameters of 50 - 200 µm have historically been made by emulsion techniques and had poor size uniformity [1, 2]. An internal gelation, sol-gel apparatus was designed and constructed to accommodate the production of small, uniform microspheres whereby cerium-containing solutions were dispersed into flowing silicone oil and heated in a gelation column to initiate solidification [3, 4]. Problems with premature feed gelation and microsphere coalescencemore » were overcome by equipment modifications unique among known internal gelation setups. Microspheres were fabricated and sized in batches as a function of dispersing needle diameter and silicone oil flow rate in the two-fluid nozzle in order to determine the range of sizes possible and corresponding degree of monodispersity. Initial experiments with poor size uniformity were linked to microsphere coalescence in the gelation column prior to solidification as well as excessive flow rates for the cerium feed solution. Average diameter standard deviations as low as 2.23% were observed after optimization of flow rates and minimization of coalescence reactions.« less

  17. Production of monodisperse cerium oxide microspheres with diameters near 100 µm by internal-gelation sol–gel methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Katalenich, Jeffrey A.; Kitchen, Brian B.; Pierson, Bruce D.

    Cerium dioxide microspheres with uniform diameters between 65 – 211 µm were fabricated using internal gelation sol-gel methods. Although uniform microspheres are produced for nuclear fuel applications with diameters above 300 µm, sol-gel microspheres with diameters of 50 - 200 µm have historically been made by emulsion techniques and had poor size uniformity [1, 2]. An internal gelation, sol-gel apparatus was designed and constructed to accommodate the production of small, uniform microspheres whereby cerium-containing solutions were dispersed into flowing silicone oil and heated in a gelation column to initiate solidification [3, 4]. Problems with premature feed gelation and microsphere coalescencemore » were overcome by equipment modifications unique among known internal gelation setups. Microspheres were fabricated and sized in batches as a function of dispersing needle diameter and silicone oil flow rate in the two-fluid nozzle in order to determine the range of sizes possible and corresponding degree of monodispersity. Initial experiments with poor size uniformity were linked to microsphere coalescence in the gelation column prior to solidification as well as excessive flow rates for the cerium feed solution. Average diameter standard deviations as low as 2.23% were observed after optimization of flow rates and minimization of coalescence reactions.« less

  18. Effect of upper body position on arterial stiffness: influence of hydrostatic pressure and autonomic function.

    PubMed

    Schroeder, Elizabeth C; Rosenberg, Alexander J; Hilgenkamp, Thessa I M; White, Daniel W; Baynard, Tracy; Fernhall, Bo

    2017-12-01

    To evaluate changes in arterial stiffness with positional change and whether the stiffness changes are due to hydrostatic pressure alone or if physiological changes in vasoconstriction of the conduit arteries play a role in the modulation of arterial stiffness. Thirty participants' (male = 15, 24 ± 4 years) upper bodies were positioned at 0, 45, and 72° angles. Pulse wave velocity (PWV), cardio-ankle vascular index, carotid beta-stiffness index, carotid blood pressure (cBP), and carotid diameters were measured at each position. A gravitational height correction was determined using the vertical fluid column distance (mmHg) between the heart and carotid artery. Carotid beta-stiffness was calibrated using three methods: nonheight corrected cBP of each position, height corrected cBP of each position, and height corrected cBP of the supine position (theoretical model). Low frequency systolic blood pressure variability (LFSAP) was analyzed as a marker of sympathetic activity. PWV and cardio-ankle vascular index increased with position (P < 0.05). Carotid beta-stiffness did not increase if not corrected for hydrostatic pressure. Arterial stiffness indices based on Method 2 were not different from Method 3 (P = 0.65). LFSAP increased in more upright positions (P < 0.05) but diastolic diameter relative to diastolic pressure did not (P > 0.05). Arterial stiffness increases with a more upright body position. Carotid beta-stiffness needs to be calibrated accounting for hydrostatic effects of gravity if measured in a seated position. It is unclear why PWV increased as this increase was independent of blood pressure. No difference between Methods 2 and 3 presumably indicates that the beta-stiffness increases are only pressure dependent, despite the increase in vascular sympathetic modulation.

  19. Mechanisms of Amplified Arteriogenesis in Collateral Artery Segments Exposed to Flow Direction Reversal

    PubMed Central

    Heuslein, Joshua L.; Meisner, Joshua K.; Li, Xuanyue; Song, Ji; Vincentelli, Helena; Leiphart, Ryan J.; Ames, Elizabeth G.; Price, Richard J.

    2015-01-01

    Objective Collateral arteriogenesis, the growth of existing arterial vessels to a larger diameter, is a fundamental adaptive response that is often critical for the perfusion and survival of tissues downstream of chronic arterial occlusion(s). Shear stress regulates arteriogenesis; however, the arteriogenic significance of flow direction reversal, occurring in numerous collateral artery segments after femoral artery ligation (FAL), is unknown. Our objective was to determine if flow direction reversal in collateral artery segments differentially regulates endothelial cell signaling and arteriogenesis. Approach and Results Collateral segments experiencing flow reversal after FAL in C57BL/6 mice exhibit increased pericollateral macrophage recruitment, amplified arteriogenesis (30% diameter and 2.8-fold conductance increases), and remarkably permanent (12 weeks post-FAL) remodeling. Genome-wide transcriptional analyses on HUVECs exposed to flow reversal conditions mimicking those occurring in-vivo yielded 10-fold more significantly regulated transcripts, as well as enhanced activation of upstream regulators (NFκB, VEGF, FGF2, TGFβ) and arteriogenic canonical pathways (PKA, PDE, MAPK). Augmented expression of key pro-arteriogenic molecules (KLF2, ICAM-1, eNOS) was also verified by qRT-PCR, leading us to test whether ICAM-1 and/or eNOS regulate amplified arteriogenesis in flow-reversed collateral segments in-vivo. Interestingly, enhanced pericollateral macrophage recruitment and amplified arteriogenesis was attenuated in flow-reversed collateral segments after FAL in ICAM-1−/− mice; however, eNOS−/− mice showed no such differences. Conclusions Flow reversal leads to a broad amplification of pro-arteriogenic endothelial signaling and a sustained ICAM-1-dependent augmentation of arteriogenesis. Further investigation of the endothelial mechanotransduction pathways activated by flow reversal may lead to more effective and durable therapeutic options for arterial occlusive diseases. PMID:26338297

  20. Outcomes of Percutaneous Closure of Patent Ductus Arteriosus Accompanied With Unilateral Absence of Pulmonary Artery.

    PubMed

    Yang, Yankun; Zheng, Hong; Xu, Zhongying; Zhang, Gejun; Jin, Jinglin; Hu, Haibo; Tian, Tao; Zhou, Xianliang

    2017-04-01

    Limited data have reported the outcomes of percutaneous closure of patent ductus arteriosus (PDA) in patients with unilateral absence of pulmonary artery (UAPA). This study aimed to evaluate the symptomatology, diagnosis and therapy, especially the transcatheter closure of PDA in patients with PDA associated with UAPA. Patients diagnosed with PDA and UAPA were retrospectively enrolled from August 2010 through January 2016. Clinical data, treatment and follow-up information were evaluated. Thirteen patients (6 males and 7 females) were diagnosed with PDA associated with UAPA. Percutaneous closure was successfully conducted in 6 patients successfully. The median age was 7 years (7 months to 37 years). The mean diameter of the PDA and occluders were 4.7 ± 1.8mm (2-7mm) and 11.3 ± 3.9mm (6-14mm), respectively. The mean pulmonary artery pressure was 41.5 ± 13.5mmHg (25-62mmHg). The diameter of PDA has no relationship with the degree of pulmonary artery pressure (r = 0.239, P = 0.648). In 4 patients, systolic pulmonary arterial pressure decreased significantly after closure with 69.0 ± 10.7 versus 48.0 ± 11.3mmHg (P = 0.146), and also the mean pulmonary arterial pressure was 54.5 ± 5.7 mm Hg versus 30.5 ± 3.9mmHg (P = 0.04). In all, 1 patient had a trace residual shunt, which disappeared within 24 hours. In appropriate patients with PDA associated with UAPA, transcatheter closure of PDA has the potential to improve the pulmonary artery hypertension. Further follow-up is required to monitor the long-term outcomes. Copyright © 2017 Southern Society for Clinical Investigation. Published by Elsevier Inc. All rights reserved.

  1. Comparison of brachial artery vasoreactivity in elite power athletes and age-matched controls.

    PubMed

    Welsch, Michael A; Blalock, Paul; Credeur, Daniel P; Parish, Tracie R

    2013-01-01

    Elite endurance athletes typically have larger arteries contributing to greater skeletal muscle blood flow, oxygen and nutrient delivery and improved physical performance. Few studies have examined structural and functional properties of arteries in power athletes. To compare the size and vasoreactivity of the brachial artery of elite power athletes to age-matched controls. It was hypothesized brachial artery diameters of athletes would be larger, have less vasodilation in response to cuff occlusion, but more constriction after a cold pressor test than age-matched controls. Eight elite power athletes (age = 23 ± 2 years) and ten controls (age = 22 ± 1 yrs) were studied. High-resolution ultrasonography was used to assess brachial artery diameters at rest and following 5 minutes of forearm occlusion (Brachial Artery Flow Mediated Dilation = BAFMD) and a cold pressor test (CPT). Basic fitness measures included a handgrip test and 3-minute step test. Brachial arteries of athletes were larger (Athletes 5.39 ± 1.51 vs. 3.73 ± 0.71 mm, p<0.05), had greater vasodilatory (BAFMD%: Athletes: 8.21 ± 1.78 vs. 5.69 ± 1.56%) and constrictor (CPT %: Athletes: -2.95 ± 1.07 vs. -1.20 ± 0.48%) responses, compared to controls. Vascular operating range (VOR = Peak dilation+Peak Constriction) was also greater in athletes (VOR: Athletes: 0.55 ± 0.15 vs. 0.25 ± 0.18 mm, p<0.05). Athletes had superior handgrip strength (Athletes: 55.92 ± 17.06 vs. 36.77 ± 17.06 kg, p<0.05) but similar heart rate responses at peak (Athletes: 123 ± 16 vs. 130 ± 25 bpm, p>0.05) and 1 minute recovery (Athletes: 88 ± 21 vs. 98 ± 26 bpm, p>0.05) following the step test. Elite power athletes have larger brachial arteries, and greater vasoreactivity (greater vasodilatory and constrictor responses) than age-matched controls, contributing to a significantly greater VOR. These data extend the existence of an 'athlete's artery' as previously shown for elite endurance athletes to elite power athletes, and presents a hypothetical explanation for the functional significance of the 'power athlete's artery'.

  2. High pressure fiber optic sensor system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guida, Renato; Xia, Hua; Lee, Boon K

    2013-11-26

    The present application provides a fiber optic sensor system. The fiber optic sensor system may include a small diameter bellows, a large diameter bellows, and a fiber optic pressure sensor attached to the small diameter bellows. Contraction of the large diameter bellows under an applied pressure may cause the small diameter bellows to expand such that the fiber optic pressure sensor may measure the applied pressure.

  3. Prehepatocholedochal proper hepatic artery. Rare anatomical variant. Surgical considerations. Case report.

    PubMed

    Ardeleanu, V; Chicoş, S; Tutunaru, D; Georgescu, C

    2014-01-01

    In classical anatomic variants, the proper hepatic artery (PHA)continues the common hepatic artery (CHA) after the gastroduodenal artery (GDA) detaches itself and divides into the right hepatic artery (RHA) and left hepatic artery (LHA), the proper hepatic artery being located to the left of the hepatocholedochal duct (HCD). This paper presents an abnormal positioning of the PHA placed before the HCD with an increased diameter of about 5-7 mm, which could be confused with the HCD. We present the case of a 57 year-old woman diagnosed with acute lithiasic cholecystitis, associated with hypersplenism and hypertension. The literature mentions manifold anatomical variants of arterial liver vascularization,including PHA. For this reason, this paper presents an overview of similar cases that can be found in medical literature. The aforementioned case is a rare topographic anatomy for the PHA that can easily pass for HCD especially during celioscopy, therefore it is crucial for this to be acknowledged by all surgeons. Celsius.

  4. Evaluation of cardiac function in a group of small for gestational age school-age children treated with growth hormone.

    PubMed

    Aurensanz Clemente, Esther; Ayerza Casas, Ariadna; Samper Villagrasa, Pilar; Ruiz Frontera, Pablo; Bueno Lozano, Gloria

    2017-02-09

    Small for gestational age (SGA) patients have an increased risk of developing a cardiovascular pathology, as well as a metabolic syndrome. Our objective is to evaluate the cardiac morphology and function of SGA children treated with growth hormone (GH), identifying changes that could potentially have long-term consequences. We selected 23 SGA school-age patients and 23 healthy children. We measured their weight, height, blood pressure and heart rate. Using transthoracic echocardiography, we evaluated cardiac chamber size, ascending and abdominal aortic diameter as well as the systolic and diastolic function of both ventricles. SGA children have a higher systolic and diastolic blood pressure (P<.05) without significant changes in their heart rate. They also have a thicker interventricular septum (SGA Z-score 1.57 vs. 0.89; P=.026) and a worse right ventricular systolic function, with a lower TAPSE (SGA Z-score -0.98 vs. 0.95; P=.000), as well as a lower blood flow rate in the pulmonary artery (SGA 0.85m/s vs. 0.97m/s; P=.045). No significant difference was observed in the patients' left ventricular function. SGA patients' ascending aortic diameter was greater (SGA Z-score -1.09 vs. -1.93; P=.026), whereas the systolic abdominal aortic diameter was smaller (SGA Z-score-0.89 vs. -0.19; P=.015). We found functional and morphological cardiac changes in SGA school-age patients treated with GH. It is important to follow-up this patient group in order to determine if these changes contribute to an increased cardiac morbidity in adulthood. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  5. Transcatheter closure of patent ductus arteriosus using the AMPLATZER™ duct occluder II (ADO II).

    PubMed

    Gruenstein, Daniel H; Ebeid, Makram; Radtke, Wolfgang; Moore, Phillip; Holzer, Ralf; Justino, Henri

    2017-05-01

    The study purpose is to evaluate the safety and efficacy of the ADO II device for closure of patent ductus arteriosus (PDA) in children. Transcatheter treatment of PDA has been evolving for 40+ years and is the treatment of choice. The AMPLATZER™ Duct Occluder (ADO) device was developed for larger diameter ducts and is not ideal in all PDAs. ADO II was developed for small to moderate-sized ducts. This is a single-arm, multicenter study evaluating safety and efficacy of the ADO II device. Patients <18 years were screened for a PDA ≤5.5 mm in diameter and 3-12 mm in length. Right and left heart catheterization was performed, and hemodynamic data were obtained at the time of implant. The diameter of the left pulmonary artery (LPA) and descending aorta, and the presence of any pre-existing pressure gradients across the LPA or aortic arch were assessed at baseline and 6 months post-implant. A total of 192 patients were enrolled. The median implant time was 74 min. Median fluoroscopy time was 12 min. A retrograde (aortic) approach was used in 33% of procedures and demonstrated a statistically significant reduction in fluoroscopy time (P value = 0.0018) compared to an antegrade approach. The device was successfully implanted in 93% of patients, with complete closure in 98% of successful implantations. In this prospective study, the ADO II was safe and effective for closure of small to moderate PDAs. Implantation is simple and the ability for retrograde aortic delivery reduces procedure-related radiation exposure. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  6. 6D.03: FLOW-MEDIATED DILATATION (FMD) AND ENDOTHELIUM-INDEPENDENT DILATATION (EID) IN PATIENTS WITH MULTIFOCAL FIBROMUSCULAR DYSPLASIA: A CROSS-SECTIONAL STUDY.

    PubMed

    Khettab, H; Lorthior, A; Niarra, R; Chambon, Y; Jeunemaitre, X; Plouin, P F; Laurent, S; Boutouyrie, P; Azizi, M

    2015-06-01

    Fibromuscular dysplasia (FD) is a rare idiopathic, segmental, non-atherosclerotic non-inflammatory vascular disease. We previously showed that FD is a general arterial disease with focal exacerbation of the trait. However, whether endothelial dysfunction may be involved in the pathophysiology of FD is unclear. In a cross sectional study, we compared the endothelial function between 50 patients with multifocal FD of renal/carotid arteries confirmed by CT-angiography, 50 essential hypertensive (EH) patients matched for age, sex, ethnicity and BP and 50 healthy subjects (HS) matched for age, sex and ethnicity. Exclusion criteria were: tobacco consumption, hypercholesterolemia, diabetes, aspirin or statin treatment. Brachial artery (BA) FMD after release of hand ischemia and glyceryl trinitrate (GTN)-induced EID was measured using a high-resolution radiofrequency-based echotracking system blind to the diagnosis. FD, EH and HS were well matched (52yrs, 85% women, 80% caucasian). SBP was higher in FD (125 ± 15mmHg) and EH (121 ± 12mmHg) than EH (113 ± 10mmHg) despite antihypertensive treatments. BA external diameter was significantly lower in FD than in both HS and EH before, during and after hand ischemia and after GTN. BA intima media thickness (IMT), internal diameter did not differ between the 3 groups. FMD (%) or EID (%) did not significantly differ between the 3 groups. BA flow velocity did not significantly differ in any experimental condition.(Figure is included in full-text article.) : In conclusion, despite showing similar acute vasodilatory responses to flow and GTN, FD patients differed from EH and HS in terms of arterial morphology with smaller BA diameter associated with similar IMT. This paradoxical remodeling may suggest a chronic defect in the endothelium-dependent pathways involved in arterial remodeling in FD patients.

  7. Vascular endothelial function and oxidative stress mechanisms in patients with Behçet's syndrome.

    PubMed

    Chambers, J C; Haskard, D O; Kooner, J S

    2001-02-01

    We sought to test the hypothesis that vascular endothelial function is impaired in Behçet's syndrome and reflects increased levels of oxidative stress. Behçet's syndrome is a multisystem inflammatory disorder commonly complicated by vascular thrombosis and arterial aneurysm formation. The precise mechanisms underlying vascular disease in Behçet's syndrome are not known. We studied 19 patients with Behçet's syndrome (18 to 50 years old, 9 men) and 21 healthy volunteers (18 to 50 years old, 10 men). Brachial artery flow-mediated dilation (endothelium-dependent), and nitroglycerin (NTG)-induced dilation (endothelium-independent) were measured. To investigate oxidative stress mechanisms, vascular studies were repeated 1 h after administration of vitamin C (1 g, intravenous) in 12 patients and 12 control subjects. Flow-mediated dilation was reduced in patients with Behcet's syndrome as compared with control subjects (0.7 +/- 0.9% vs. 5.7 +/- 0.9%, p = 0.001). In contrast, there were no significant differences in the brachial artery diameter (4.2 +/- 0.2 vs. 4.0 +/- 0.2 mm, p = 0.47) or NTG-induced dilation (19.7 +/- 1.9% vs. 19.7 +/- 1.2%, p = 0.98). In regression analysis, Behçet's syndrome was associated with impaired flow-mediated dilation independent of age, gender, brachial artery diameter, blood pressure, cholesterol and glucose. Vitamin C increased flow-mediated dilation in Behçet's syndrome (0.2 +/- 0.7% to 3.5 +/- 1.0%, p = 0.002), but not in control subjects (4.3 +/- 0.6% to 4.7 +/- 0.4%, p = 0.51). In both groups, NTG-induced dilation and brachial artery diameter were unchanged after vitamin C treatment. Vascular endothelial function is impaired in Behcet's syndrome and can be rapidly improved by vitamin C treatment. Our results support a role for oxidative stress in the pathophysiology of Behçet's syndrome and provide a rationale for therapeutic studies aimed at reducing vascular complications in this disorder.

  8. Contribution of kv7.4/kv7.5 heteromers to intrinsic and calcitonin gene-related peptide-induced cerebral reactivity.

    PubMed

    Chadha, Preet S; Jepps, Thomas A; Carr, Georgina; Stott, Jennifer B; Zhu, Hei-Lei; Cole, William C; Greenwood, Iain A

    2014-04-01

    Middle cerebral artery (MCA) diameter is regulated by inherent myogenic activity and the effect of potent vasodilators such as calcitonin gene-related peptide (CGRP). Previous studies showed that MCAs express KCNQ1, 4, and 5 potassium channel genes, and the expression products (Kv7 channels) participate in the myogenic control of MCA diameter. The present study investigated the contribution of Kv7.4 and Kv7.5 isoforms to myogenic and CGRP regulation of MCA diameter and determined whether they were affected in hypertensive animals. Isometric tension recordings performed on MCA from normotensive rats produced CGRP vasodilations that were inhibited by the pan-Kv7 channel blocker linopirdine (P<0.01) and after transfection of arteries with siRNA against KCNQ4 (P<0.01) but not KCNQ5. However, isobaric myography revealed that myogenic constriction in response to increases in intravascular pressure (20-80 mm Hg) was affected by both KCNQ4 and KCNQ5 siRNA. Proximity ligation assay signals were equally abundant for Kv7.4/Kv7.4 or Kv7.4/Kv7.5 antibody combinations but minimal for Kv7.5/Kv7.5 antibodies or Kv7.4/7.1 combinations. In contrast to systemic arteries, Kv7 function and Kv7.4 abundance in MCA were not altered in hypertensive rats. This study reveals, for the first time to our knowledge, that in cerebral arteries, Kv7.4 and Kv7.5 proteins exist predominantly as a functional heterotetramer, which regulates intrinsic myogenicity and vasodilation attributed to CGRP. Surprisingly, unlike systemic arteries, Kv7 activity in MCAs is not affected by the development of hypertension, and CGRP-mediated vasodilation is well maintained. As such, cerebrovascular Kv7 channels could be amenable for therapeutic targeting in conditions such as cerebral vasospasm.

  9. Dimensional analysis of human saphenous vein grafts: Implications for external mesh support.

    PubMed

    Human, Paul; Franz, Thomas; Scherman, Jacques; Moodley, Lovendran; Zilla, Peter

    2009-05-01

    Constrictive external mesh support of vein grafts was shown to mitigate intimal hyperplasia in animal experiments. To determine the degree of constriction required for the elimination of dimensional irregularities in clinically used vein grafts, a detailed anatomic study of human saphenous veins was conducted. In 200 consecutive patients having coronary artery bypass grafting, harvested saphenous veins (length 34.4 +/- 10.8 cm) were analyzed regarding diameter irregularities, side branch distribution, and microstructure. The mean outer diameter of surgically distended saphenous veins was 4.2 +/- 0.6 mm (men, 4.3 +/- 0.6 mm vs women, 3.9 +/- 0.5 mm; P < .0001). Although the outer diameter significantly decreased over the initial 18 cm (-7.6%; P < .0001), the overall increase between malleolus and thigh was not significant (+11.2%). Smaller-diameter veins (<3.5 mm) had more pronounced diameter fluctuations than larger veins (31.8% +/- 11.0% vs 21.2% +/- 8.8%; P < .0001), with more than 71% of all veins showing caliber changes of more than 20%. There was 1 side branch every 5.4 +/- 4.3 cm, with a significantly higher incidence between 20 and 32 cm from the malleolus (P < .0001 to distal, P < .0004 to proximal). Generally, women had more side branches than men (0.30 +/- 0.15 cm(-1) vs 0.25 +/- 0.12 cm(-1); P = .0190). Thick-walled veins (565.7 +/- 138.4 mum) had a significantly higher number of large side branches (P < .0001), and thin-walled veins (398.7 +/- 123.2 mum) had significantly more small side branches (P < .0001). Pronounced intimal thickening ("cushions") was found in 28% of vessels (119.8 +/- 28.0 mum vs 40.1 +/- 18.2 mum; P < .0001). Although the preferential location of side branches may be addressed by the deliberate discarding of infragenicular vein segments, a diameter constriction of 27% on average would eliminate diameter irregularities in 98% of vein grafts.

  10. Electrical neuromodulation for disabling angina pectoris related to isolated stenoses of small epicardial coronary arteries.

    PubMed

    Jessurun, G A; Hautvast, R W; DeJongste, M J; Meyler, W J; van Boven AJ; Crijns, H J

    1999-07-01

    Patients with symptomatic small vessel coronary artery disease may be inadequate candidates for revascularization procedures. They may suffer from refractory angina, which does not respond to maximal anti-anginal drug therapy. In addition to patients with end stage coronary artery disease and syndrome X, this newly defined group of subjects with an isolated stenosis of a small coronary artery may benefit from electrical neurostimulation. We describe two patients with intractable angina caused by a significant narrowing of a diagonal branch. This treatment modality should be considered as an alternative method for unsatisfactory revascularization procedures.

  11. Solitary Hepatocellular Carcinoma Fed by the Cystic Artery: Limitation of Transcatheter Arterial Embolization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hirota, Shozo; Matsumoto, Shinichi; Fukuda, Tetsuya

    1999-05-15

    Purpose: To clarify the limitations of transcatheter treatment for hepatocellular carcinoma (HCC) with parasitic feeders from the cystic artery. Methods: Three male patients had a solitary HCC (average diameter 3 cm) fed by the cystic artery among 221 patients with HCC from 1994 to 1997. One tumor was nourished entirely from the cystic artery arising from the medial branch of the left hepatic artery, and two tumors were fed partially by the cystic arteries arising from the anterior inferior branch of the right hepatic artery. We analyzed the indications for transcatheter treatment for these three patients. Results: We chose notmore » to embolize the cystic artery for fear of necrosis of the gallbladder. Although embolization of the anterior branch of the right hepatic artery was performed in one patient with a tumor fed partially by the cystic artery, only half the tumor was embolized. Two patients underwent hepatic resection, and one received percutaneous ethanol injection therapy. At follow-up of 28-40 months (average 33 months) all patients are alive. Conclusion: Feeding by the cystic artery represents a limitation of TAE for HCC.« less

  12. Distal Ulnar Artery Aneurysm Repair by End-to-End Technique: A Case Report.

    PubMed

    Cotroneo, Attilio; Barillà, David; Armienti, Felice; Martinelli, Gian Luca; Diena, Marco

    2018-01-01

    We report the case of a 33-year-old man presented with a posttraumatic 20-mm left ulnar artery aneurysm without intraluminal thrombus in the left hypothenar eminence. The patient reported left hand paresthesia. Because of symptoms and the embolic risk, we decide to plan an aneurysm resection and an interposition graft with inverted basilic vein for adequacy diameter (∼2 mm), but an end-to-end anastomosis was performed instead. We think that the posttraumatic distal artery aneurysm could be treated without a bypass but, after a meticulous anatomic dissection, with a microvascular anastomosis between the artery stumps. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Automated detection and classification of major retinal vessels for determination of diameter ratio of arteries and veins

    NASA Astrophysics Data System (ADS)

    Muramatsu, Chisako; Hatanaka, Yuji; Iwase, Tatsuhiko; Hara, Takeshi; Fujita, Hiroshi

    2010-03-01

    Abnormalities of retinal vasculatures can indicate health conditions in the body, such as the high blood pressure and diabetes. Providing automatically determined width ratio of arteries and veins (A/V ratio) on retinal fundus images may help physicians in the diagnosis of hypertensive retinopathy, which may cause blindness. The purpose of this study was to detect major retinal vessels and classify them into arteries and veins for the determination of A/V ratio. Images used in this study were obtained from DRIVE database, which consists of 20 cases each for training and testing vessel detection algorithms. Starting with the reference standard of vasculature segmentation provided in the database, major arteries and veins each in the upper and lower temporal regions were manually selected for establishing the gold standard. We applied the black top-hat transformation and double-ring filter to detect retinal blood vessels. From the extracted vessels, large vessels extending from the optic disc to temporal regions were selected as target vessels for calculation of A/V ratio. Image features were extracted from the vessel segments from quarter-disc to one disc diameter from the edge of optic discs. The target segments in the training cases were classified into arteries and veins by using the linear discriminant analysis, and the selected parameters were applied to those in the test cases. Out of 40 pairs, 30 pairs (75%) of arteries and veins in the 20 test cases were correctly classified. The result can be used for the automated calculation of A/V ratio.

  14. Morphometry of A1 segment of the anterior cerebral artery and its clinical importance.

    PubMed

    Krishnamurthy, A; Nayak, S R; Bagoji, I B; D'Costa, S; Pai, M M; Jiji, P J; Kumar, C G; Rai, R

    2010-01-01

    Anterior cerebral artery, one of the terminal branches of the internal carotid artery is an important vessel taking part in the formation of circle of Willis. It supplies a large part of the medial surface of the cerebral hemisphere containing the areas of motor and somatosensory cortices of the lower limb. Aim of this study was the morphometry of A1 segment of the anterior cerebral artery. 93 formalin fixed brain specimen of either sex and of Indian origin were studied. The mean length, mean external diameter and the anomalies present in A1 segment of the vessel were studied in detail and photographed. The mean length of A1 segment of the vessel was 14.49+/-0.28 mm and 14.22+/-0.22 mm on right and left side respectively. The mean external diameter of the vessel on right and left side was 2.12+/-0.07 mm and 2.32+/-0.06 mm respectively. Narrowing, aneurysm formation, buttonhole formation and median anterior cerebral artery were the anomalies seen with an occurrence of 15.05%, 5.37%, 3.22% and 12.9%, respectively. The above anomalies did not have any sex or side predilection. Knowledge of morphometry of the vessel will be of use to neurosurgeons while performing the shunt operation, in assessing the feasibility of such operations and in the choice of patients. From this study we infer that the morphometry of anterior cerebral artery varies in different population and that the neurosurgeons operating should have a thorough knowledge of the possible variations.

  15. Flow-mediated changes in pulse wave velocity: a new clinical measure of endothelial function.

    PubMed

    Naka, Katerina K; Tweddel, Ann C; Doshi, Sagar N; Goodfellow, Jonathan; Henderson, Andrew H

    2006-02-01

    To test whether measuring hyperaemic changes in pulse wave velocity (PWV) could be used as a new method of assessing endothelial function for use in clinical practice. Flow-mediated changes in vascular tone may be used to assess endothelial function and may be induced by distal hyperaemia, while endothelium-mediated changes in vascular tone can influence PWV. These three known principles were combined to provide and test a novel method of measuring endothelial function by the acute effects of distal hyperaemia on upper and lower limb PWV (measured by a recently developed method). Flow-mediated changes in upper and lower limb PWV were compared in 17 healthy subjects and seven patients with stable chronic heart failure (CHF), as a condition where endothelial function is impaired but endothelium-independent dilator responses are retained. Corroborative measurements of PWV and brachial artery diameter responses to endothelium-dependent and -independent pharmacological stimuli were performed in a further eight healthy subjects. Flow-mediated reduction of PWV (by 14% with no change in blood pressure) was found in normal subjects but was almost abolished in patients with CHF. PWV responses appear to be inversely related to and relatively greater than brachial artery diameter responses. The method may offer potential advantages of practical use and sensitivity over conduit artery diameter responses to measure endothelial dysfunction.

  16. Embolization of a large, symptomatic splenic artery pseudoaneurysm

    PubMed Central

    Kukliński, Adam; Batycki, Krzysztof; Matuszewski, Wiesław; Ostrach, Andrzej; Kupis, Zbigniew; Łęgowik, Tomasz

    2014-01-01

    Summary Background Splenic artery aneurysm is the third most common abdominal aneurysm. Most often it is due to pancreatitis. There were only 19 cases of aneurysms larger than 5 cm in diameter described in the literature. Management of splenic artery aneurysms depends on the size and symptoms. Invasive treatment modalities involve open procedures and interventional radiology methods (endovascular). Case Reports A 44-years-old male with chronic pancreatitis, in a gradually worsening general condition due to a large splenic artery aneurysm, was subjected to the procedure. Blood flow through the aneurysm was cut-off by implanting a covered stent between celiac trunk and common hepatic artery. Patient’s general condition rapidly improved, allowing discharge home in good state soon after the procedure. Conclusions Percutaneous embolization appears to be the best method of treatment of large splenic artery aneurysms. Complications of such treatment are significantly less dangerous than those associated with surgery. PMID:25009678

  17. [The state of carotid arteries in young men with arterial hypertension].

    PubMed

    Safarova, A F; Iurtaeva, V R; Kotovskaia, Iu V; Kobalava, Zh D

    2012-01-01

    To study elastic properties of carotid arteries in young men with arterial hypertension (AH). We examined men aged 18-25 years (mean 21.1+/-0.14 years): 36 with normal blood pressure (BP), 123 with stable and 51 with unstable AH. Parameters studied comprised intima-media thickness (IMT) of carotid arteries, their M-mode measured maximal systolic and minimal diastolic diameters (Ds and Dd), stiffness of common carotid artery (CCA) wall determined on the basis of analysis of elasticity and distensibility coefficients (CC and DC), Peterson's and Young's modules of elasticity (Ep and E), and index of flow deformation (CS). Compared with young men with normal BP and unstable AH patients with stable AH had abnormal elastic properties of CCA and increased IMT. Stable AH in young men is associated with signs of remodeling of CCA walls and increase of their rigidity.

  18. A Review on Atherosclerotic Biology, Wall Stiffness, Physics of Elasticity, and Its Ultrasound-Based Measurement.

    PubMed

    Patel, Anoop K; Suri, Harman S; Singh, Jaskaran; Kumar, Dinesh; Shafique, Shoaib; Nicolaides, Andrew; Jain, Sanjay K; Saba, Luca; Gupta, Ajay; Laird, John R; Giannopoulos, Argiris; Suri, Jasjit S

    2016-12-01

    Functional and structural changes in the common carotid artery are biomarkers for cardiovascular risk. Current methods for measuring functional changes include pulse wave velocity, compliance, distensibility, strain, stress, stiffness, and elasticity derived from arterial waveforms. The review is focused on the ultrasound-based carotid artery elasticity and stiffness measurements covering the physics of elasticity and linking it to biological evolution of arterial stiffness. The paper also presents evolution of plaque with a focus on the pathophysiologic cascade leading to arterial hardening. Using the concept of strain, and image-based elasticity, the paper then reviews the lumen diameter and carotid intima-media thickness measurements in combined temporal and spatial domains. Finally, the review presents the factors which influence the understanding of atherosclerotic disease formation and cardiovascular risk including arterial stiffness, tissue morphological characteristics, and image-based elasticity measurement.

  19. Can Coulomb repulsion for charged particle beams be overcome?

    NASA Astrophysics Data System (ADS)

    Retsky, Michael W.

    2004-01-01

    Mutual repulsion of discrete charged particles or Coulomb repulsion is widely considered to be an ultimate hard limit in charged particle optics. It prevents the ability to finely focus high current beams into a small spots at large distances from the defining apertures. A classic example is the 1970s era "Star Wars" study of an electron beam directed energy weapon as an orbiting antiballistic missile device. After much analysis, it was considered physically impossible to focus a 1000-amp 1-GeV beam into a 1-cm diameter spot 1000-km from the beam generator. The main reason was that a 1-cm diameter beam would spread to 5-m diameter at 1000-km due to Coulomb repulsion. Since this could not be overcome, the idea was abandoned. But is this true? What if the rays were reversed? That is, start with a 5-m beam converging slightly with the same nonuniform angular and energy distribution as the electrons from the original problem were spreading at 1000-km distance. Could Coulomb repulsion be overcome? Looking at the terms in computational studies, some are reversible while others are not. Since the nonreversible terms should be small, it might be possible to construct an electron beam directed energy weapon.

  20. Safety and Clinical Outcome of the Delivery of Radiofrequency Nerve Ablation Therapy in a Renal Artery of Unusual Anatomy.

    PubMed

    de Leon-Martinez, Enrique Ponce; Garza, Javier A; Azpiri-Lopez, Jose R; Dillon, Krista N; Salazar, Leonel Olivas; Canepa-Campos, Francisco; Rousselle, Serge D; Tellez, Armando

    2015-12-01

    Catheter-based renal sympathetic denervation is an emerging therapy for resistant hypertension (RHTN) patients, resulting in a significant blood pressure reduction. The presence of accessory renal arteries and anomalous branching patterns are reported in approximately 20-27 % of patients. However, accessory renal arteries, when smaller than 4 mm in diameter, they are out of the inclusion criteria for renal denervation therapy. For this reason patients with evidence of accessory renal arteries have been excluded in previous clinical trials. Recent data suggest that accessory renal arteries may play an important role in non-response therapy when they do not receive renal denervation treatment. In this report, we present the outcome of a patient with resistant hypertension and an anomalous right renal artery, having undergone denervation of both principal and accessory renal arteries. The renal ablation by radiofrequency energy of a distant accessory renal artery resulted in a safe procedure with no clinical complications. Consistent with literature the RDN of all, main and accessory renal arteries, was effective in decreasing patient blood pressure while decreasing the need for antihypertensive medication.

  1. Pre-operative Duplex Ultrasonography in Arteriovenous Fistula Creation: Intra- and Inter-observer Agreement.

    PubMed

    Zonnebeld, Niek; Maas, Tommy M G; Huberts, Wouter; van Loon, Magda M; Delhaas, Tammo; Tordoir, Jan H M

    2017-11-01

    Although clinical guidelines on arteriovenous fistula (AVF) creation advocate minimum luminal arterial and venous diameters, assessed by duplex ultrasonography (DUS), the clinical value of routine DUS examination is under debate. DUS might be an insufficiently repeatable and/or reproducible imaging modality because of its operator dependency. The present study aimed to assess intra- and inter-observer agreement of DUS examination in support of AVF surgery planning. Ten end stage renal disease patients were included, to assess intra- and inter-observer agreement of pre-operative DUS measurements. All measurements were performed by two trained and experienced vascular technicians, blinded to measurement readings. From the routine DUS protocol, representative measurements (venous diameters, and arterial diameters and volume flow in the upper arm and forearm) were selected. For intra-observer agreement the measurements were performed in triplicate, with the probe released from the skin between each. Intraclass correlation coefficients were calculated for intra- and inter-observer agreement, and Bland-Altman plots used to graphically display mean measurement differences and limits of agreement. Ten patients (6 male, 59.4±19.7 years) consented to participate, and all predefined measurements were obtained. Intraclass correlation coefficients for intra-observer agreement of diameter measurements were at least 0.90 (95% CI 0.74-0.97; radial artery). Inter-observer agreement was at least 0.83 (0.46-0.96; lateral diameter upper arm cephalic vein). The Bland-Altman plots showed acceptable mean measurement differences and limits of agreement. In experienced hands, excellent intra- and inter-observer agreement can be reached for the discrete pre-operative DUS measurements advocated in clinical guidelines. DUS is therefore a reliable imaging modality to support AVF surgery planning. The content of DUS protocols, however, needs further standardisation. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  2. Retrospective morphometric study of the suitability of renal arteries for renal denervation according to the Symplicity HTN2 trial criteria

    PubMed Central

    Schönherr, Elisabeth; Rehwald, Rafael; Nasseri, Parinaz; Luger, Anna K; Grams, Astrid E; Kerschbaum, Julia; Rehder, Peter; Petersen, Johannes; Glodny, Bernhard

    2016-01-01

    Objective The aim of this study was to describe the renal arteries of humans in vivo, as precisely as possible, and to formulate an expected value for the exclusion of renal denervation due to the anatomical situation based on the criteria of the Symplicity HTN trials. Design and setting In a retrospective cohort study, the renal arteries of 126 patients (57 women, 69 men, mean age 60±17.2 years (CI 57.7 to 63.6)) were segmented semiautomatically from high-contrast CT angiographies. Results Among the 300 renal arteries, there were three arteries with fibromuscular dysplasia and one with ostial renal artery stenosis. The first left renal artery was shorter than the right (34±11.4 mm (CI 32 to 36) vs 45.9±15 mm (CI 43.2 to 48.6); p<0.0001), but had a slightly larger diameter (5.2±1.4 mm (CI 4.9 to 5.4) vs 4.9±1.2 mm (CI 4.6 to 5.1); p>0.05). The first left renal arteries were 1.1±0.4 mm (CI 0.9 to 1.3), and the first right renal arteries were 0.3±0.6 mm (CI 0.1 to 0.5) thinner in women than in men (p<0.05). Ostial funnels were up to 14 mm long. The cross-sections were elliptical, more pronounced on the right side (p<0.05). In 23 cases (18.3%), the main artery was shorter than 2 cm; in 43 cases (34.1%), the diameter was not >4 mm. Some 46% of the patients, or 58.7% when variants and diseases were taken into consideration, were theoretically not suitable for denervation. Conclusions Based on these precise measurements, the anatomical situation as a reason for ruling out denervation appears to be significantly more common than previously suspected. Since this can be the cause of the failure of treatment in some cases, further development of catheters or direct percutaneous approaches may improve success rates. PMID:26729385

  3. The effects of Y-27632 on pial microvessels during global brain ischemia and reperfusion in rabbits.

    PubMed

    Shintani, Noriyuki; Ishiyama, Tadahiko; Kotoda, Masakazu; Asano, Nobumasa; Sessler, Daniel I; Matsukawa, Takashi

    2017-03-07

    Global brain ischemia-reperfusion during propofol anesthesia provokes persistent cerebral pial constriction. Constriction is likely mediated by Rho-kinase. Cerebral vasoconstriction possibly exacerbates ischemic brain injury. Because Y-27632 is a potent Rho-kinase inhibitor, it should be necessary to evaluate its effects on cerebral pial vessels during ischemia-reperfusion period. We therefore tested the hypotheses that Y-27632 dilates cerebral pial arterioles after the ischemia-reperfusion injury, and evaluated the time-course of cerebral pial arteriolar status after the ischemia-reperfusion. Japanese white rabbits were anesthetized with propofol, and a closed cranial window inserted over the left hemisphere. Global brain ischemia was produced by clamping the brachiocephalic, left common carotid, and left subclavian arteries for 15 min. Rabbits were assigned to cranial window perfusion with: (1) artificial cerebrospinal fluid (Control group, n = 7); (2) topical infusion of Y-27632 10 -6 mol · L -1 for 30 min before the initiation of global brain ischemia (Pre group, n = 7); (3) topical infusion of Y-27632 10 -6 mol · L -1 starting 30 min before ischemia and continuing throughout the study period (Continuous group, n = 7); and, (4) topical infusion of Y-27632 10 -6 mol · L -1 starting 10 min after the ischemia and continuing until the end of the study (Post group, n = 7). Cerebral pial arterial and venule diameters were recorded 30 min before ischemia, just before arterial clamping, 10 min after clamping, and 5, 10, 20, 40, 60, 80, 100, and 120 min after unclamping. Mean arterial blood pressure and blood glucose concentration increased significantly after global brain ischemia except in the Continuous group. In the Pre and Continuous groups, topical application of Y-27632 produced dilation of large (mean 18-19%) and small (mean; 25-29%) pial arteries, without apparent effect on venules. Compared with the Control and Pre groups, arterioles were significantly dilated during the reperfusion period in the Continuous and Post groups (mean at 120 min: 5-8% in large arterioles and 11-12% in small arterioles). Y-27632 dilated cerebral pial arterioles during reperfusion. Y-27632 may enhance recovery from ischemia by preventing arteriolar vasoconstriction during reperfusion.

  4. Structural and functional remodeling of skeletal muscle microvasculature is induced by simulated microgravity

    NASA Technical Reports Server (NTRS)

    Delp, M. D.; Colleran, P. N.; Wilkerson, M. K.; McCurdy, M. R.; Muller-Delp, J.

    2000-01-01

    Hindlimb unloading of rats results in a diminished ability of skeletal muscle arterioles to constrict in vitro and elevate vascular resistance in vivo. The purpose of the present study was to determine whether alterations in the mechanical environment (i.e., reduced fluid pressure and blood flow) of the vasculature in hindlimb skeletal muscles from 2-wk hindlimb-unloaded (HU) rats induces a structural remodeling of arterial microvessels that may account for these observations. Transverse cross sections were used to determine media cross-sectional area (CSA), wall thickness, outer perimeter, number of media nuclei, and vessel luminal diameter of feed arteries and first-order (1A) arterioles from soleus and the superficial portion of gastrocnemius muscles. Endothelium-dependent dilation (ACh) was also determined. Media CSA of resistance arteries was diminished by hindlimb unloading as a result of decreased media thickness (gastrocnemius muscle) or reduced vessel diameter (soleus muscle). ACh-induced dilation was diminished by 2 wk of hindlimb unloading in soleus 1A arterioles, but not in gastrocnemius 1A arterioles. These results indicate that structural remodeling and functional adaptations of the arterial microvasculature occur in skeletal muscles of the HU rat; the data suggest that these alterations may be induced by reductions in transmural pressure (gastrocnemius muscle) and wall shear stress (soleus muscle).

  5. The comparison of high and standard definition computed tomography techniques regarding coronary artery imaging.

    PubMed

    Aykut, Aktas; Bumin, Degirmenci; Omer, Yilmaz; Mustafa, Kayan; Meltem, Cetin; Orhan, Celik; Nisa, Unlu; Hikmet, Orhan; Hakan, Demirtas; Mert, Koroglu

    2015-09-01

    The aim was to compare coronary high-definition CT (HDCT) with standard-definition CT (SDCT) angiography as to radiation dose, image quality and accuracy. 28 patients with history of coronary artery disease scanned by HDCT (Discovery CT750 HD) and SDCT (Somatom Definition AS). The scan modes were both axial prospective ECG-triggered. The vessel diameters and vessel attenuation values of totally 280 measurements from 140 coronary arteries were analyzed by two experienced radiologists. All data was analyzed by intraclass correlation test. Image quality graded by motion and stair step artifacts (grade 1, poor, to grade 4, excellent), accuracy of vessel inner and outer diameters were compared between the two CT units using the independent samples t-test and Mann-Whitney U test. The intraclass correlation coefficient (ICC) of measured vessel attenuation values in SDCT between the two radiologists was exceedingly good. The ICC was higher in HDCT. The radiation dose of HDCT was higher than that of SDCT. The mean tube current was 180 (mA) in HDCT and 147(mA) in SDCT with the same tube voltage (kVp). There was no significant difference between image quality. HDCT has a higher radiation dose but has much more atenuation and the spatial resolution which improve measurement accuracy for imaging coronary arteries.

  6. Influence of Puncture Site on Radial Artery Occlusion After Transradial Coronary Intervention.

    PubMed

    Bi, Xi-Le; Fu, Xiang-Hua; Gu, Xin-Shun; Wang, Yan-Bo; Li, Wei; Wei, Li-Ye; Fan, Yan-Ming; Bai, Shi-Ru

    2016-04-20

    The risk of radial artery occlusion (RAO) needs particular attention in transradial intervention (TRI). Therefore, reducing vascular occlusion has an important clinical significance. The aim of this study was to determine the appropriate puncture site during TRI through comparing the occurrence of RAO between the different puncture sites to reduce the occurrence of RAO after TRI. We prospectively assessed the occurrence of RAO in 606 consecutive patients undergoing TRI. Artery occlusion was evaluated with Doppler ultrasound in 2 days and 1 year after the intervention. Risk factors for RAO were evaluated using a multivariate model analysis. Of the 606 patients, the RAO occurred in 56 patients. Compared with TRI at 2-5 cm away from the radius styloid process, the odds ratio (OR) for occlusion risk at 0 cm and 1 cm were 9.65 (P = 0.033) and 8.90 (P = 0.040), respectively. The RAO occurred in the ratio of the arterial diameter to the sheath diameter ≤1 (OR = 2.45, P = 0.004). Distal puncture sites (0-1 cm away from the radius styloid process) can lead to a higher rate of RAO. ClinicalTrials.gov, NCT01979627; https://clinicaltrials.gov/ct2/show/NCT01979627?term = NCT01979627 and rank = 1.

  7. Clinical Significance of the Champagne Bottle Neck Sign in the Extracranial Carotid Arteries of Patients with Moyamoya Disease.

    PubMed

    Yasuda, C; Arakawa, S; Shimogawa, T; Kanazawa, Y; Sayama, T; Haga, S; Morioka, T

    2016-05-26

    The champagne bottle neck sign represents a rapid reduction in the extracranial ICA diameters and is a characteristic feature of Moyamoya disease. However, the clinical significance of the champagne bottle neck sign is unclear. We investigated the relationship between the champagne bottle neck sign and the clinical and hemodynamic stages of Moyamoya disease. We analyzed 14 patients with Moyamoya disease before revascularization (5 men, 9 women; age, 43.2 ± 19.3 years). The ratio of the extracranial ICA and common carotid artery diameters was determined using carotid ultrasonography or cerebral angiography; a ratio of < 0.5 was considered champagne bottle neck sign-positive. The clinical disease stage was determined using the Suzuki angiographic grading system. CBF and cerebral vasoreactivity also were measured. The ICA/common carotid artery ratio (expressed as median [interquartile range]) decreased as the clinical stage advanced (stages I-II, 0.71 [0.60-0.77]; stages III-IV, 0.49 [0.45-0.57]; stages V-VI, 0.38 [0.34-0.47]; P < .001). Lower ICA/common carotid artery ratio tended to occur in symptomatic versus asymptomatic arteries (0.47 [0.40-0.53] versus 0.57 [0.40-0.66], respectively; P = .06). Although the ICA/common carotid artery ratio was not related to cerebral perfusion, it decreased as cerebral vasoreactivity decreased (P < .01). All champagne bottle neck sign-positive arteries were classified as Suzuki stage ≥III, 73% were symptomatic, and 89% exhibited reduced cerebral vasoreactivity. In contrast, all champagne bottle neck sign-negative arteries were Suzuki stage ≤III, 67% were asymptomatic, and all showed preserved cerebral vasoreactivity. The champagne bottle neck sign was related to advanced clinical stage, clinical symptoms, and impaired cerebral vasoreactivity. Thus, detection of the champagne bottle neck sign might be useful in determining the clinical and hemodynamic stages of Moyamoya disease. © 2016 American Society of Neuroradiology.

  8. Near-Field Scanning Optical Microscopy and Raman Microscopy.

    NASA Astrophysics Data System (ADS)

    Harootunian, Alec Tate

    1987-09-01

    Both a one dimensional near-field scanning optical microscope and Raman microprobe were constructed. In near -field scanning optical microscopy (NSOM) a subwavelength aperture is scanned in the near-field of the object. Radiation transmitted through the aperture is collected to form an image as the aperture scans over the object. The resolution of an NSOM system is essentially wavelength independent and is limited by the diameter of the aperture used to scan the object. NSOM was developed in an effort to provide a nondestructive in situ high spatial resolution probe while still utilizing photons at optical wavelengths. The Raman microprobe constructed provided vibrational Raman information with spatial resolution equivalent that of a conventional diffraction limited microscope. Both transmission studies and near-field diffration studies of subwavelength apertures were performed. Diffraction theories for a small aperture in an infinitely thin conducting screen, a slit in a thick conducting screen, and an aperture in a black screen were examined. All three theories indicate collimation of radiation to the size to the size of the subwavelength aperture or slit in the near-field. Theoretical calculations and experimental results indicate that light transmitted through subwavelength apertures is readily detectable. Light of wavelength 4579 (ANGSTROM) was transmitted through apertures with diameters as small as 300 (ANGSTROM). These studies indicate the feasibility of constructing an NSOM system. One dimensional transmission and fluorescence NSOM systems were constructed. Apertures in the tips of metallized glass pipettes width inner diameters of less than 1000 (ANGSTROM) were used as a light source in the NSOM system. A tunneling current was used to maintain the aperture position in the near-field. Fluorescence NSOM was demonstrated for the first time. Microspectroscopic and Raman microscopic studies of turtle cone oil droplets were performed. Both the Raman vibrational frequencies and the Raman excitation data indicate that the carotenoids are unaggregated. The carotenoid astaxanthin was identified in the orange and red droplets by Raman microscopy. Future applications for both Raman microscopy and near-field microscopy were proposed. Four methods of near-field distance regulation were also examined. Finally, theoretical exposure curves for near-field lithography were calculated. Both the near-field lithographic results and the near field diffraction studies indicate essentially wavelength independent resolution. (Abstract shortened with permission of author.).

  9. The small community solar thermal power experiment. Parabolic dish technology for industrial process heat application

    NASA Technical Reports Server (NTRS)

    Polzien, R. E.; Rodriguez, D.

    1981-01-01

    Aspects of incorporating a thermal energy transport system (ETS) into a field of parabolic dish collectors for industrial process heat (IPH) applications were investigated. Specific objectives are to: (1) verify the mathematical optimization of pipe diameters and insulation thicknesses calculated by a computer code; (2) verify the cost model for pipe network costs using conventional pipe network construction; (3) develop a design and the associated production costs for incorporating risers and downcomers on a low cost concentrator (LCC); (4) investigate the cost reduction of using unconventional pipe construction technology. The pipe network design and costs for a particular IPH application, specifically solar thermally enhanced oil recovery (STEOR) are analyzed. The application involves the hybrid operation of a solar powered steam generator in conjunction with a steam generator using fossil fuels to generate STEOR steam for wells. It is concluded that the STEOR application provides a baseline pipe network geometry used for optimization studies of pipe diameter and insulation thickness, and for development of comparative cost data, and operating parameters for the design of riser/downcomer modifications to the low cost concentrator.

  10. Vascular affection in relation to oxidative DNA damage in metabolic syndrome.

    PubMed

    Abd El Aziz, Rokayaa; Fawzy, Mary Wadie; Khalil, Noha; Abdel Atty, Sahar; Sabra, Zainab

    2018-02-01

    Obesity has become an important issue affecting both males and females. Obesity is now regarded as an independent risk factor for atherosclerosis-related diseases. Metabolic syndrome is associated with increased risk for development of cardiovascular disease. Urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine concentration has been used to express oxidation status. Twenty-seven obese patients with metabolic syndrome, 25 obese patients without metabolic syndrome and 31 healthy subjects were included in our study. They were subjected to full history and clinical examination; fasting blood sugar (FBS), 2 hour post prandial blood sugar (2HPP), lipid profile, urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine and carotid duplex, A/B index and tibial diameters were all assessed. There was a statistically significant difference ( p = 0.027) in diameter of the right anterior tibial artery among the studied groups, with decreased diameter of the right anterior tibial artery in obese patients with metabolic syndrome compared to those without metabolic syndrome; the ankle brachial index revealed a lower index in obese patients with metabolic syndrome compared to those without metabolic syndrome. There was a statistically insignificant difference ( p = 0.668) in the 8-oxodG in the studied groups. In obese patients with metabolic syndrome there was a positive correlation between 8-oxodG and total cholesterol and LDL. Urinary 8-oxodG is correlated to total cholesterol and LDL in obese patients with metabolic syndrome; signifying its role in the mechanism of dyslipidemia in those patients. Our study highlights the importance of anterior tibial artery diameter measurement and ankle brachial index as an early marker of atherosclerosis, and how it may be an earlier marker than carotid intima-media thickness.

  11. Reactivity of retinal blood flow to 100% oxygen breathing after lipopolysaccharide administration in healthy subjects.

    PubMed

    Kolodjaschna, Julia; Berisha, Fatmire; Lasta, Michael; Polska, Elzbieta; Fuchsjäger-Mayrl, Gabriele; Schmetterer, Leopold

    2008-08-01

    Administration of low doses of Escherichia coli endotoxin (LPS) to humans enables the study of inflammatory mechanisms. The purpose of the present study was to investigate the retinal vascular reactivity after LPS infusion. In a randomized placebo-controlled cross-over study, 18 healthy male volunteers received 20 IU/kg LPS or placebo as an intravenous bolus infusion. Outcome parameters were measured at baseline and 4h after LPS/placebo administration. At baseline and at 4h after administration a short period of 100% oxygen inhalation was used to assess retinal vasoreactivity to this stimulus. Perimacular white blood cell velocity, density and flux were assessed with the blue-field entoptic technique, retinal branch arterial and venous diameters were measured with a retinal vessel analyzer and red blood cell velocity in retinal branch veins was measured with laser Doppler velocimetry. LPS is associated with peripheral blood leukocytosis and increased white blood cell density in ocular microvessels (p<0.001). In addition, retinal arterial (p=0.02) and venous (p<0.01) diameters were increased. All retinal hemodynamic parameters showed a decrease during 100% oxygen breathing. This decrease was significantly blunted by LPS for all retinal outcome parameters except venous diameter (p=0.04 for white blood cell velocity, p=0.0002 for white blood cell density, p<0.0001 for white blood cell flux, p=0.01 for arterial diameter, p=0.02 for red blood cell velocity and p=0.006 for red blood cell flux). These data indicate that LPS-induced inflammation induces vascular dysregulation in the retina. This may provide a link between inflammation and vascular dysregulation. Further studies are warranted to investigate whether this model may be suitable to study inflammation induced vascular dysregulation in the eye.

  12. Evaluation of the Zeiss retinal vessel analyser

    PubMed Central

    Polak, K.; Dorner, G.; Kiss, B.; Polska, E.; Findl, O.; Rainer, G.; Eichler, H.; Schmetterer, L.

    2000-01-01

    AIM—To investigate the reproducibility and sensitivity of the Zeiss retinal vessel analyser, a new method for the online determination of retinal vessel diameters in healthy subjects.
METHODS—Two model drugs were administered, a peripheral vasoconstrictor (the α receptor agonist phenylephrine) and a peripheral vasodilator (the nitric oxide donor sodium nitroprusside) in stepwise increasing doses. Nine healthy young subjects were studied in a placebo controlled double masked three way crossover design. Subjects received intravenous infusions of either placebo or stepwise increasing doses of phenylephrine (0.5, 1, or 2 µg/kg/min) or sodium nitroprusside (0.5, 1, or 2 µg/kg/min). Retinal vessel diameters were measured with the new Zeiss retinal vessel analyser. Retinal leucocyte velocity, flow, and density were measured with the blue field entoptic technique. The reproducibility of measurements was assessed with coefficients of variation and intraclass correlation coefficients.
RESULTS—Placebo and phenylephrine did not influence retinal haemodynamics, although the α receptor antagonist significantly increased blood pressure. Sodium nitroprusside induced a significant increase in retinal venous and arterial diameters (p<0.001 each), leucocyte density (p=0.001), and leucocyte flow (p=0.024) despite lowering blood pressure to a significant degree. For venous and arterial vessel size measurements short term coefficients of variation were 1.3% and 2.6% and intraclass correlation coefficients were 0.98 and 0.96, respectively. The sensitivity was between 3% and 5% for retinal veins and 5% and 7% for retinal arteries.
CONCLUSIONS—These data indicate that the Zeiss retinal vessel analyser is an accurate system for the assessment of retinal diameters in healthy subjects. In addition, nitric oxide appears to have a strong influence on retinal vascular tone.

 PMID:11049956

  13. Lacunar infarction and small vessel disease: pathology and pathophysiology.

    PubMed

    Caplan, Louis R

    2015-01-01

    Two major vascular pathologies underlie brain damage in patients with disease of small size penetrating brain arteries and arterioles; 1) thickening of the arterial media and 2) obstruction of the origins of penetrating arteries by parent artery intimal plaques. The media of these small vessels may be thickened by fibrinoid deposition and hypertrophy of smooth muscle and other connective tissue elements that accompanies degenerative changes in patients with hypertension and or diabetes or can contain foreign deposits as in amyloid angiopathy and genetically mediated conditions such as cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy. These pathological changes lead to 2 different pathophysiologies: 1) brain ischemia in regions supplied by the affected arteries. The resultant lesions are deep small infarcts, most often involving the basal ganglia, pons, thalami and cerebral white matter. And 2) leakage of fluid causing edema and later gliosis in white matter tracts. The changes in the media and adventitia effect metalloproteinases and other substances within the matrix of the vessels and lead to abnormal blood/brain barriers in these small vessels. and chronic gliosis and atrophy of cerebral white matter.

  14. "Accordion" deformity of a tortuous external iliac artery after stent-graft placement.

    PubMed

    Quinn, S F; Kim, J; Sheley, R C; Frankhouse, J H

    2001-02-01

    To identify a complication of endograft deployment in aneurysmal iliac arteries. A 71-year-old man was referred for endovascular treatment of a 60-mm-diameter right common iliac artery aneurysm; however, deployment of a homemade covered stent (Palmaz-Schatz and polytetrafluoroethylene) induced shortening of the tortuous external iliac artery, causing an "accordion" deformity. The anomaly proved difficult to treat with serial Wallstent deployment, because the convolution tightened and migrated caudally with each stent deployed, threatening outflow. Finally, after 3 Wallstents were implanted, the contour of the external iliac artery was straight, and flow was unimpeded. However, 3 weeks later, the external iliac artery had recoiled to its original redundant appearance, but flow remained satisfactory. The aneurysm remains excluded, with satisfactory distal flow after 24 months. Implanting endografts in redundant, tortuous arterial segments may prove problematic, since induced straightening by the device precipitates kinking in the redundant system. Although treatment may be required in some situations, the vessels may return to a noncompressed state by removing the delivery system and guidewire.

  15. Peripheral artery disease - legs

    MedlinePlus

    ... flow, which can injure nerves and other tissues. Causes PAD is caused by "hardening of the arteries." ... small arteries Coronary artery disease Impotence Open sores (ischemic ulcers on the lower legs) Tissue death (gangrene) ...

  16. Aging-related arterial-cardiac interaction in Japanese men.

    PubMed

    Maruyama, Yoshiaki

    2009-11-01

    Vascular and cardiac aging is rapidly progressing among the Japanese population. A close relation exists between the artery and cardiac performance (arterial-cardiac interaction), but the relationships between age and these parameters have not been well examined. The aim of this study was to elucidate the changes of arterial-cardiac interaction with aging, using pulse wave velocity (PWV) as an indicator of atherosclerosis. The subjects comprised 595 adult men (mean age, 58.8 +/- 12.2 years) without any history of cardiovascular disease. After correlating PWV, cardiac structure, cardiac function, and blood pressure to age, subjects were divided into five age groups to compare changes in these parameters. Pulse wave velocity exhibited a strong positive correlation with age (r = 0.461, P < 0.01) and increased significantly over 55 years old, and left atrial dimension, relative wall thickness, systolic blood pressure, and pulse pressure correlated positively with age and increased similarly. Left ventricular volume correlated negatively with age and decreased similarly. These parameters significantly correlated with PWV. Aortic diameter (AoD) positively and EA ratio (E/A) negatively exhibited a correlation with age and revealed earlier change before PWV increase. Aortic diameter increased significantly over 45 years old and stayed flat, but E/A decreased linearly from the early period. Diastolic blood pressure (DBP) increased in the early period and decreased over 75 years of age. Agerelated atherosclerotic close arterial-cardiac interaction exists between the vessels and cardiac performance, but AoD, E/A, and DBP change in early age independent of atherosclerosis.

  17. An Automatic Method for Measurements of Arterial Intima-Media Thickness Using Ultrasonic B-Mode Data

    NASA Astrophysics Data System (ADS)

    Cinthio, Magnus; Ahlgren, Åsa Rydén; Jansson, Tomas; Nilsson, Tobias; Lindström, Kjell; Persson, Hans W.

    We have previously developed algorithms that use B-mode cineloops for simultaneous measurements of arterial diameter change and longitudinal movement of the arterial wall. In this study the lumen diameter algorithm was extended to also measure arterial intima-media thickness of the far wall. To optimize the algorithm the influence of the lateral width of the region-of-interest (1 pixel, 0.1 mm, 0.5 mm, 1 mm, 2.5 mm and 5 mm) was evaluated. The algorithm estimated intima-media thickness at diastole automatically by measuring the distance between the two positions where the laterally averaged B-mode intensity envelope crosses a threshold value relative to the maximum amplitudes of the intimal and adventitial echoes, respectively. The sub-pixel resolution is achieved by solving the equation of a straight line between the two samples on either side of the threshold value. The measurements were performed on 20 healthy normotensive volunteers (age 25-57 years) on the common carotid artery 2-3 cm proximal to the bifurcation. For the 2.5-mm width, which was considered the best, the intima-media thickness was mean 646 μm (SD 66) for men and 613 μm (SD 68) for women. The systematic difference was -5 μm and the random difference was 31 μm. The CV was 4.9%. The study indicates that the reproducibility is sufficient for in vivo studies when the width of the region-of-interest is 1.0 mm or wider.

  18. Soft-template construction of three-dimensionally ordered inverse opal structure from Li2FeSiO4/C composite nanofibers for high-rate lithium-ion batteries

    NASA Astrophysics Data System (ADS)

    Li, Donglin; Zhang, Wei; Sun, Ru; Yong, Hong-Tuan-Hua; Chen, Guangqi; Fan, Xiaoyong; Gou, Lei; Mao, Yiyang; Zhao, Kun; Tian, Miao

    2016-06-01

    Exploring a new method to fabricate small-sized nanofibers is essential to achieve superior performances for energy conversion and storage devices. Here, a novel soft-template strategy is developed to synthesize a three-dimensionally ordered macroporous (3DOM) architecture constructed from small-sized nanofibers. The effectiveness of a nanofiber-assembled three-dimensional inverse opal material as an electrode for high-rate lithium-ion batteries is demonstrated. The small-sized Li2FeSiO4/C composite nanofibers with a diameter of 20-30 nm are grown by employing a tri-block copolymer P123 as a structure directing agent. Accordingly, the macro-mesoporous hierarchical 3DOM architecture constructed from Li2FeSiO4/C nanofibers is further templated from P123 for the nanofibers and a polystyrene colloidal crystal array for the 3DOM architecture. We find that the thermal stability of the nanofiber morphology depends on the self-limited growth of Li2FeSiO4 nanocrystals in a crystalline-amorphous hybrid. As a cathode for a lithium-ion battery, the 3D hierarchical macro-mesoporous cathodes exhibit outstanding high-rate and ultralong-life performances with a capacity retention of 84% after 1500 cycles at 5 C in the voltage window of 1.5-4.5 V, which is greatly improved compared with a simple 3DOM Li2FeSiO4/C nanocomposite.Exploring a new method to fabricate small-sized nanofibers is essential to achieve superior performances for energy conversion and storage devices. Here, a novel soft-template strategy is developed to synthesize a three-dimensionally ordered macroporous (3DOM) architecture constructed from small-sized nanofibers. The effectiveness of a nanofiber-assembled three-dimensional inverse opal material as an electrode for high-rate lithium-ion batteries is demonstrated. The small-sized Li2FeSiO4/C composite nanofibers with a diameter of 20-30 nm are grown by employing a tri-block copolymer P123 as a structure directing agent. Accordingly, the macro-mesoporous hierarchical 3DOM architecture constructed from Li2FeSiO4/C nanofibers is further templated from P123 for the nanofibers and a polystyrene colloidal crystal array for the 3DOM architecture. We find that the thermal stability of the nanofiber morphology depends on the self-limited growth of Li2FeSiO4 nanocrystals in a crystalline-amorphous hybrid. As a cathode for a lithium-ion battery, the 3D hierarchical macro-mesoporous cathodes exhibit outstanding high-rate and ultralong-life performances with a capacity retention of 84% after 1500 cycles at 5 C in the voltage window of 1.5-4.5 V, which is greatly improved compared with a simple 3DOM Li2FeSiO4/C nanocomposite. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr07783d

  19. Transcatheter closure of patent ductus arteriosus with Nit-Occlud coils.

    PubMed

    Celiker, Alpay; Aypar, Ebru; Karagöz, Tevfik; Dilber, Embiya; Ceviz, Naci

    2005-08-01

    The detachable coils have been successfully used for transcatheter occlusion of small- to moderate-sized patent ductus arteriosus (PDA). We report our experience regarding the use of the Nit-Occlud coils (NOCs) for transcatheter PDA and major aortopulmonary collateral (MAPCA) occlusion. Single NOCs were used to close PDA in 26 patients, and one small and two large MAPCAs in two patients. Mean age and weight of the patients were 7.7 +/- 5.4 years and 20.6 +/- 11.6 kg. Mean minimum duct diameter was 2.8 +/- 0.8 mm; ampulla, 8.7 +/- 2.4 mm; and PDA length, 9.3 +/- 4.4 mm. Mean pulmonary artery pressure ranged from 9 to 51 mm Hg and pulmonary/systemic flow ratio from 1.1 to 5.8. Ductal shape was conical in 24 patients. Route of approach was venous in 23 and arterial in 3. Successful coil implantation was achieved in 24/26 (92.3%). Mean procedure and fluoroscopy time were 67.2 +/- 22.1 and 14.9 +/- 6.5 min. The three MAPCAs were also successfully occluded using NOC Medium and Flex. Postimplantation angiograms revealed no leak in 3, a trace or small leak in 17, and a medium leak in 4 patients. Mean follow-up was 7 +/- 5 months. Complete occlusion was achieved in 17/24 (71%) at 24 hr, 19/24 (79%) by 1 month, 13/15 (87%) by 3 months, 14/15 (93%) by 6 months, and 10/11 (90%) by 12 months postprocedure. Hemolysis, late embolization, duct recanalization, and flow disturbances were not observed. Transcatheter occlusion of moderate-sized PDAs and MAPCAs using NOCs seems to offer a safe, simple, and controlled method in pediatric patients.

  20. Composite casting/bonding construction of an air-cooled, high temperature radial turbine wheel

    NASA Technical Reports Server (NTRS)

    Hammer, A. N.; Aigret, G.; Rodgers, C.; Metcalfe, A. G.

    1983-01-01

    A composite casting/bonding technique has been developed for the fabrication of a unique air-cooled, high temperature radial inflow turbine wheel design applicable to auxilliary power units with small rotor diameters and blade entry heights. The 'split blade' manufacturing procedure employed is an alternative to complex internal ceramic coring. Attention is given to both aerothermodynamic and structural design, of which the latter made advantageous use of the exploration of alternative cooling passage configurations through CAD/CAM system software modification.

Top